Sample records for clinically failed fixed

  1. Fracture Surface Analysis of Clinically Failed Fixed Partial Dentures

    PubMed Central

    Taskonak, B.; Mecholsky, J.J.; Anusavice, K.J.

    2008-01-01

    Ceramic systems have limited long-term fracture resistance, especially when they are used in posterior areas or for fixed partial dentures. The objective of this study was to determine the site of crack initiation and the causes of fracture of clinically failed ceramic fixed partial dentures. Six Empress 2® lithia-disilicate (Li2O·2SiO2)-based veneered bridges and 7 experimental lithia-disilicate-based non-veneered ceramic bridges were retrieved and analyzed. Fractography and fracture mechanics methods were used to estimate the stresses at failure in 6 bridges (50%) whose fracture initiated from the occlusal surface of the connectors. Fracture of 1 non-veneered bridge (8%) initiated within the gingival surface of the connector. Three veneered bridges fractured within the veneer layers. Failure stresses of the all-core fixed partial dentures ranged from 107 to 161 MPa. Failure stresses of the veneered fixed partial dentures ranged from 19 to 68 MPa. We conclude that fracture initiation sites are controlled primarily by contact damage. PMID:16498078

  2. Clinical and Radiographic Assessment of Reasons for Replacement of Metal- Ceramic Fixed Dental Prostheses in Patients Referring to Dental School.

    PubMed

    Al Refai, Roa'a; Saker, Samah

    2018-01-01

    The expected length of service and reasons for fixed dental prostheses (FDPs) replacement are a frequent inquiry by patients while the answers were mainly based on studies reports that was conducted outside the middle east region. This clinical and radiographic survey was constructed to assess and survey clinically and radiographically the reasons of replacement of metal-ceramic fixed dental prostheses, amongst patients reporting at dental school in Taibah University. Between January and May 2016, 151 patients were recruited for this study. Interview (include questions pertained to the length of service of the prosthesis, the nature of complaint as told by patient in her own words), clinical examination, intra-oral photographs, and periapical radiographs, were done by the researchers. The parameters assessed were secondary caries, open margins, loss of retention, failure of endodontic treatment of the abutment and periodontal diseases. A total number of 249 failed fixed dental prostheses were evaluated. Of which 180 (39.7%) were single crowns, 159 (35.0%) were retainers and 117 (25.8%) were pontics in 69 fixed partial denture. The most common reason for replacement of fixed restorations was periodontal diseases affecting 92.8% of all types' restorations, followed by defective margin in 90.4% of examined restoration, poor aesthetic in 88% of restorations, while periapical involvement was found in 85.5% of fixed dental prosthesis. The survival rates of fixed prostheses were not predictable, and no association was found between number of years in service and the number of restorations. The most common reasons for replacing single unit fixed dental prostheses are periodontal diseases and periapical involvement, while defective margins and poor aesthetic mainly associated with multi-unit fixed dental prostheses. Key words: Failure, Fixed dental prosthesis, Survival, Replacement.

  3. The Role of Tertiary Education in Fixing Failed States: Globalization and Public Goods

    ERIC Educational Resources Information Center

    Tierney, William G.

    2011-01-01

    The plight of nations labeled as "failed" is well-documented, as are suggested strategies to fix them. One area that receives a great deal of focus in the extant literature is education. How can education contribute to the rebuilding of a failed State? Most often the responses to this question focus on the importance of reestablishing primary and…

  4. [Resin infiltration of white spot lesions during the fixed orthodontic appliance therapy].

    PubMed

    Ogodescu, A; Ogodescu, Emilia; Talpoş, S; Zetu, Irina

    2011-01-01

    To investigate the evolution of resin infiltrated white spot lesions (WSLs) during 10 month of fixed orthodontic appliance therapy using the photographic examination method. Twelve patients with mild decalcifications prior to the orthodontic treatment were examined once each month. At aggravation of the WSLs, by patients who fail to maintain good oral hygiene, the brackets were taken down, the lesions were infiltrated with resin (ICON) and the brackets were bonded in place. WSLs were evaluated from intraoral photographs taken before and during the treatment. 35.2% of existing lesions aggravated in the first 6 months of treatment. 41.2 % of the W.S.L. were considered severe and were infiltrated. In the next 10 month of orthodontic treatment 92.5% of the infiltrated WSLs were clinically stable. This clinical study showed a positive evolution of the resin infiltrated WSLs during the fixed orthodontic therapy. This is especially important for patients with long periods of treatment like interdisciplinary orthodontic-orthognathic surgery cases or patients that are refractory to oral hygiene measures.

  5. Dealing with failed deregulation: what would price c. Watts do?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rothkopf, Michael H.

    2007-08-15

    There has been much thought given to ways that might fix deregulated markets, and there is still no agreement on the correct fix. The once-pseudonymous Price C. Watts thinks it is time to think seriously about ways to reregulate where deregulation has failed. Here are some steps to get us there. (author)

  6. Comparison of Fixed Dental Prostheses with Zirconia and Metal Frameworks: Five-Year Results of a Randomized Controlled Clinical Trial.

    PubMed

    Sailer, Irena; Balmer, Marc; Hüsler, Jürg; Hämmerle, Christoph Hans Franz; Känel, Sarah; Thoma, Daniel Stefan

    The aim of this study was to test whether posterior zirconia-ceramic (ZC) and metal-ceramic (MC) fixed dental prostheses (FDPs) exhibit similar survival and technical/biologic complication rates. A total of 58 patients in need of 76 posterior FDPs were randomly assigned to receive 40 ZC and 36 MC FDPs. The restorations were examined at baseline (cementation) and yearly for 5 years. Technical and biologic outcomes were compared. The independent treatment groups were compared with nonparametric Mann-Whitney test for metric variables and with Fisher exact test for categoric data. A total of 52 patients with 40 ZC and 29 MC FDPs were examined at 5 years. No FDP failed during the 5 years; 2 ZC FDPs failed at 65.4 and 73.3 months. Debonding occurred at 3 ZC FDPs. Technical outcomes (modified US Public Health Service criteria) and general periodontal parameters did not show significant differences between ZC and MC FDPs. ZC FDPs exhibited similar outcomes to MC FDPs based on 5-year survival estimates. The majority of technical and biologic outcome measures were not significantly different.

  7. Clinical trials in crisis: four simple methodologic fixes

    PubMed Central

    Vickers, Andrew J.

    2014-01-01

    There is growing consensus that the US clinical trials system is broken, with trial costs and complexity increasing exponentially, and many trials failing to accrue. Yet concerns about the expense and failure rate of randomized trials are only the tip of the iceberg; perhaps what should worry us most is the number of trials that are not even considered because of projected costs and poor accrual. Several initiatives, including the Clinical Trials Transformation Initiative and the “Sensible Guidelines Group” seek to push back against current trends in clinical trials, arguing that all aspects of trials - including design, approval, conduct, monitoring, analysis and dissemination - should be based on evidence rather than contemporary norms. Proposed here are four methodologic fixes for current clinical trials. The first two aim to simplify trials, reducing costs and increasing patient acceptability by dramatically reducing eligibility criteria - often to the single criterion that the consenting physician is uncertain which of the two randomized arms is optimal - and by clinical integration, investment in data infrastructure to bring routinely collected data up to research grade to be used as endpoints in trials. The second two methodologic fixes aim to shed barriers to accrual, either by cluster randomization of clinicians (in the case of modifications to existing treatment) or by early consent, where patients are offered the chance of being randomly selected to be offered a novel intervention if disease progresses at a subsequent point. Such solutions may be partial, or result in a new set of problems of their own. Yet the current crisis in clinical trials mandates innovative approaches: randomized trials have resulted in enormous benefits for patients and we need to ensure that they continue to do so. PMID:25278228

  8. Clinical trials in crisis: Four simple methodologic fixes.

    PubMed

    Vickers, Andrew J

    2014-12-01

    There is growing consensus that the US clinical trials system is broken, with trial costs and complexity increasing exponentially, and many trials failing to accrue. Yet, concerns about the expense and failure rate of randomized trials are only the tip of the iceberg; perhaps what should worry us most is the number of trials that are not even considered because of projected costs and poor accrual. Several initiatives, including the Clinical Trials Transformation Initiative and the "Sensible Guidelines Group" seek to push back against current trends in clinical trials, arguing that all aspects of trials-including design, approval, conduct, monitoring, analysis, and dissemination-should be based on evidence rather than contemporary norms. Proposed here are four methodologic fixes for current clinical trials. The first two aim to simplify trials, reducing costs, and increasing patient acceptability by dramatically reducing eligibility criteria-often to the single criterion that the consenting physician is uncertain which of the two randomized arms is optimal-and by clinical integration, investment in data infrastructure to bring routinely collected data up to research grade to be used as endpoints in trials. The second two methodologic fixes aim to shed barriers to accrual, either by cluster randomization of clinicians (in the case of modifications to existing treatment) or by early consent, where patients are offered the chance of being randomly selected to be offered a novel intervention if disease progresses at a subsequent point. Such solutions may be partial, or result in a new set of problems of their own. Yet, the current crisis in clinical trials mandates innovative approaches: randomized trials have resulted in enormous benefits for patients, and we need to ensure that they continue to do so. © The Author(s) 2014.

  9. 76 FR 67519 - Self-Regulatory Organizations; Fixed Income Clearing Corporation; Notice of Filing of Proposed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-01

    ... Expand the Applicability of the Fails Charge to Agency Debt Securities Transactions October 26, 2011... the fails charge to Agency debt securities transactions. II. Self-Regulatory Organization's Statement... Federal Reserve Bank of New York (the ``FRBNY''), has been addressing the persistent settlement fails in...

  10. 78 FR 25115 - Self-Regulatory Organizations; Fixed Income Clearing Corporation; Notice of Filing of Proposed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-29

    ... Amending the Mortgage-Backed Securities Division Fails Charge Rule To Reflect Recommendation of the... change is to amend the existing fails charge rule in FICC's Mortgage-Backed Securities Division (``MBSD... (``TMPG'') relating to the removal of the resolution period for fails charges.\\3\\ \\3\\ The text of the...

  11. Clinical evaluation of immediate loading of electroeroded screw-retained titanium fixed prostheses supported by tilted implant: a multicenter retrospective study.

    PubMed

    Acocella, Alessandro; Ercoli, Carlo; Geminiani, Alessandro; Feng, Changyong; Billi, Mauro; Acocella, Gabriele; Giannini, Domenico; Sacco, Roberto

    2012-05-01

    Immediate occlusal loading of dental implants in the edentulous mandible has proven to be an effective, reliable, and predictable treatment protocol. However, there is limited long-term data available in the literature, when an electroeroded definitive cast-titanium fixed prosthesis is used for this treatment protocol. The aim of this study was to evaluate the clinical effectiveness of dental implants (Astra Tech Dental, Mölndal, Sweden) in the edentulous mandible immediately loaded with an electroeroded cast-titanium screw-retained fixed prosthesis. Forty-five patients received five implants each in the interforaminal area. All the implants were inserted with torque up to 40 Ncm and the distal implants were distally tilted approximately 20 to 30 degrees to minimize the length of posterior cantilevers. Implants were loaded within 48 hours of placement with an acrylic resin-titanium screw-retained prosthesis fabricated by electroerosion. Two of the 225 inserted implants failed after 3 and 16 months of healing, respectively, with a cumulative survival rate of 99.1% and a prosthetic survival rate of 97.8%. Immediate loading of tilted dental implants inserted in the edentulous mandible with a screw-retained titanium definitive prosthesis fabricated with electrical discharge machining provide reliable and predictable results. © 2011 Wiley Periodicals, Inc.

  12. Microdose GnRH Agonist Flare-Up versus Ultrashort GnRH Agonist Combined with Fixed GnRH Antagonist in Poor Responders of Assisted Reproductive Techniques Cycles.

    PubMed

    Eftekhar, Maryam; Mohammadian, Farnaz; Yousefnejad, Fariba; Khani, Parisa

    2013-01-01

    This study compares the microdose flare-up protocol to the ultrashort gonadotropinreleasing hormone (GnRH) agonist flare combined with the fixed multidose GnRH antagonist protocol in poor responders undergoing ovarian stimulation. In this randomized clinical trial, 120 women who were candidates for assisted reproductive techniques (ART) and had histories of one or more failed in vitro fertilization (IVF) cycles with three or fewer retrieved oocytes were prospectively randomized into two groups. Group I (60 patients) received the microdose flare-up regimen and group II (60 patients) received the ultrashort GnRH agonist combined with fixed GnRH antagonist. There were no significant differences between the groups in the number of used gonadotropin ampoules (p=0.591), duration of stimulation (p=0.610), number of retrieved oocytes (p=0.802), fertilization rate (p=0.456), and the number of transferred embryos (p=0.954). The clinical pregnancy rates were statistically similar in group I (10%) compared with group II (13.3%, p=0.389). According to our results, there is no significant difference between these protocols for improving the ART outcome in poor responders. Additional prospective, randomized studies with more patients is necessary to determine the best protocol (Registration Number: IRCT201105096420N1).

  13. Consequences of orthodontic treatment in malocclusion patients: clinical and microbial effects in adults and children.

    PubMed

    Guo, Li; Feng, Ying; Guo, Hong-Gang; Liu, Bo-Wen; Zhang, Yang

    2016-10-28

    Malocclusion is a common disease of oral and maxillofacial region. The study was aimed to investigate levels changes of periodontal pathogens in malocclusion patients before, during and after orthodontic treatments, and to confirm the difference between adults and children. One hundred and eight malocclusion patients (46 adults and 62 children at the school-age) were randomly selected and received orthodontic treatment with fixed orthodontic appliances. Subgingival plaques were Porphyromonas gingivalis (P.gingivalis), Fusobacterium nucleatum (F. nucleatum), Prevotella intermedia (P. intermedia) and Tannerella forsythensis (T. forsythensis) collected from the observed regions before and after treatment. Clinical indexes, including plaque index (PLI), gingival index (GI), sulcus bleeding index (SBI), probing depth (PD) and attachment loss (AL) of observed teeth were examined. The detection rates of P.gingivalis, F. nucleatum, P. intermedia and T. forsythensis increased from baseline to the third month without significant difference, and then returned to pretreatment levels 12 month after applying fixed orthodontic appliances. Adults' percentage contents of P.gingivalis, F. nucleatum, P. intermedia and T. forsythensis were significantly higher than those of children at baseline and the first month, but not obvious at the third month. PLI and SBI were increased from baseline to the first and to the third month both in adults and children groups. Besides, PD were increased from baseline to first month, followed by a downward trend in the third month; however, all patients were failed to detect with AL. Periodontal and microbiological statuses of malocclusion patients may be influenced by fixed orthodontic appliances in both adults and children, more significant in children than in adults. Some microbiological indexes have synchronous trend with the clinical indexes. Long-term efficacy of fixed orthodontic appliances for malocclusion should be confirmed by future researches.

  14. Active-standby servovalue/actuator development

    NASA Technical Reports Server (NTRS)

    Masm, R. K.

    1973-01-01

    A redundant, fail/operate fail/fixed servoactuator was constructed and tested along with electronic models of a servovalve. It was found that a torque motor switch is satisfactory for the space shuttle main engine hydraulic actuation system, and that this system provides an effective failure monitoring technique.

  15. P.F.C Sigma® cruciate retaining fixed-bearing versus mobile-bearing knee arthroplasty: a prospective comparative study with minimum 10-year follow-up.

    PubMed

    Riaz, O; Aqil, A; Sisodia, G; Chakrabarty, G

    2017-12-01

    To prospectively compare long-term clinical and radiological outcomes following a cruciate retaining fixed-bearing (FB) and a mobile-bearing (MB) primary total knee replacement (TKR). We prospectively reviewed 113 TKRs in 99 patients (14 bilateral) with a PFC sigma cruciate retaining rotating platform system, at an average follow-up of 11.1 years (range 10-12). Results were contrasted with those from 89 TKRs in 72 patients (17 bilateral) with a PFC sigma cruciate fixed-bearing prosthesis, at an average follow-up of 12.1 years (range 10-14.1). Outcomes collected included pre- and post-operative range of motion, Oxford Knee Scores, complications encountered, as well as radiographical assessments of polyethylene wear. In the MB group, mean Oxford Knee Scores improved from 16 pre-operatively to 42 at final follow-up. The mean range of motion was 115° (75-130). In the FB group, mean Oxford Knee Scores improved from 16.2 pre-operatively to 42.5 at final follow-up. The mean range of motion was 111.2 (80-135) degrees at final follow-up. We failed to elicit an objectively demonstrable clinical difference between the MB- and FB-implanted knees. Similarly, radiological benefits of the MB implants with regard to polyethylene wear were not evident at a minimum 10-year follow-up.

  16. Microdose GnRH Agonist Flare-Up versus Ultrashort GnRH Agonist Combined with Fixed GnRH Antagonist in Poor Responders of Assisted Reproductive Techniques Cycles

    PubMed Central

    Eftekhar, Maryam; Mohammadian, Farnaz; Yousefnejad, Fariba; Khani, Parisa

    2013-01-01

    Background: This study compares the microdose flare-up protocol to the ultrashort gonadotropinreleasing hormone (GnRH) agonist flare combined with the fixed multidose GnRH antagonist protocol in poor responders undergoing ovarian stimulation. Materials and Methods: In this randomized clinical trial, 120 women who were candidates for assisted reproductive techniques (ART) and had histories of one or more failed in vitro fertilization (IVF) cycles with three or fewer retrieved oocytes were prospectively randomized into two groups. Group I (60 patients) received the microdose flare-up regimen and group II (60 patients) received the ultrashort GnRH agonist combined with fixed GnRH antagonist. Results: There were no significant differences between the groups in the number of used gonadotropin ampoules (p=0.591), duration of stimulation (p=0.610), number of retrieved oocytes (p=0.802), fertilization rate (p=0.456), and the number of transferred embryos (p=0.954). The clinical pregnancy rates were statistically similar in group I (10%) compared with group II (13.3%, p=0.389). Conclusion: According to our results, there is no significant difference between these protocols for improving the ART outcome in poor responders. Additional prospective, randomized studies with more patients is necessary to determine the best protocol (Registration Number: IRCT201105096420N1). PMID:24520450

  17. Fixed-combination treatments for intraocular hypertension in Chinese patients – focus on bimatoprost-timolol

    PubMed Central

    Fang, Yuan; Ling, Zhihong; Sun, Xinghuai

    2015-01-01

    Glaucoma is a common eye disease that can lead to irreversible vision loss if left untreated. The early diagnosis and treatment of primary open-angle glaucoma is challenging, and visual impairment in Chinese glaucoma patients is a serious concern. Most of these patients need more than one topical antiglaucoma agent to control their intraocular pressures (IOPs). In the People’s Republic of China, the daily cost of different glaucoma medication varies greatly, and the treatment habits differ throughout the country. Prostaglandin analogs (PGAs) are recommended as first-line monotherapy, because of their efficacy and low risk of systemic side effects. Fixed-combination drops, particularly PGA-based fixed combinations, have recently been developed and used in patients with progression or who have failed to achieve their target IOPs. Here, we reviewed the current literature on the use of bimatoprost-timolol fixed combination (BTFC) in the People’s Republic of China. BTFC has achieved good efficacy and tolerability in Chinese clinical trials. In addition, BTFC is more cost effective compared with other fixed combinations available in the People’s Republic of China. Fixed-combination drops may offer benefits, such as keeping the ocular surface healthy, convenience of administration, and improvement in long-term adherence and quality of life. Therefore, BTFC has great potential for the treatment of Chinese glaucoma patients. However, the long-term efficacy of BTFC, comparisons of BTFC with other fixed-combination drugs, and treatment adherence and persistence with treatment in Chinese patients are unknown and will require further study. PMID:25999695

  18. EAO consensus conference: economic evaluation of implant-supported prostheses.

    PubMed

    Beikler, Thomas; Flemmig, Thomas F

    2015-09-01

    There are various alternatives for the management of oral conditions that may lead to or already have lead to partial or full edentulism. Economic evaluations measure the efficiency of alternative healthcare interventions and provide useful information for decision-making and the allocation of scarce resources. The current English literature dealing with "cost-effectiveness" of dental implant therapy versus different alternative treatment modalities, that is, complete and fixed partial dentures, root canal, and periodontal treatment, has been included in this narrative review. Due to the high heterogeneity within the literature, a meta-analysis could not be conducted. The available evidence from economic evaluations indicated that for the treatment of central incisors with irreversible pulpitis and coronal lesions, root canal treatments were most cost-effective initial treatment options. When initial root canal treatments failed, orthograde retreatments were most cost-effective. When root canal retreatments failed, extractions and replacement with single implant-supported crowns were more cost-effective compared to fixed or removable partial dentures. In the treatment of periodontitis in molars with Class I furcation invasion, non-surgical periodontal therapy was more effective and costed less than implant-supported single crowns. For the replacement of single missing teeth, two evaluations indicated that implant-supported single crowns provided better outcomes in terms of greater quality-adjusted tooth years or survival rates at lower costs compared to fixed partial prostheses. Another economic evaluation found that implant-supported crowns costed more, but provided greater survival rates compared to fixed partial dentures. For the restoration of edentulous mandibles, two evaluations indicated that overdentures retained by two or four implants improved oral health-related quality of life outcomes, but costed more than complete dentures. To better assess the efficiency of implant-supported prostheses in various clinical conditions, more economic evaluations are needed that follow well-established methodologies in health economics. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Military applications of emission and susceptibility data

    NASA Astrophysics Data System (ADS)

    Kohlbacher, Howard; Walker, William

    A basic design consideration for new military communications-electronics (C-E) equipment is that it be electromagnetically compatible with the environment in which it will operate. A military standard (MIL-STD-461B) describes the design requirements for the control of the unintentional electromagnetic emission and susceptibility characteristics of electronic equipment and subsystems designed or procured by the US Department of Defense. For new systems which fail the test standards of MIL-STD-461B with regard to radiated susceptibility (RSO3) or radiated emissions (RE02), a decision must be made to fix the new system or to field it without a fix. A procedure to aid in the decision process is outlined. The minimum separation distances required between a failed test system and other C-E equipment in its environment to avoid interference are determined. If this distance is operationally acceptable, the failed unit may be considered to be operationally compatible with its electromagnetic environment.

  20. The Art of Saving a Failing School

    ERIC Educational Resources Information Center

    Stein, Les

    2012-01-01

    While the debate continues over whether to close failing schools or attempt fixing them, the author asserts that the solution most often lies in assigning strong leaders to them who will take definite and immediate action. Reviewing his own success turning around schools, he says creating a sense of urgency, unloading poor performing staff, and…

  1. State Strategies for Fixing Failing Schools and Districts. Issue Brief

    ERIC Educational Resources Information Center

    Wakelyn, David

    2011-01-01

    At least 5,000 public schools have failed to meet their academic achievement targets for at least five consecutive years. The underlying causes of such failure are usually a combination of weak leadership, inadequate skill levels among teachers, and insufficient high-quality teaching materials. In 2009, the National Governors Association Center…

  2. 29 CFR 778.304 - Amounts deducted from cash wages-general.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dues) or required by law (such as taxes and garnishments). (4) Reductions in a fixed salary paid for a fixed workweek in weeks in which the employee fails to work the full schedule. (5) Deductions for... 778.304 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR...

  3. Strength of fixation constructs for basilar osteotomies of the first metatarsal.

    PubMed

    Lian, G J; Markolf, K; Cracchiolo, A

    1992-01-01

    Twenty-four pairs of fresh-frozen human feet had a proximal osteotomy of the first metatarsal that was fixed using either screws, staples, or K wires. Each metatarsal was excised and the specimen was loaded to failure in a cantilever beam configuration by applying a superiorly directed force to the metatarsal head using an MTS servohydraulic test machine. Specimens with a crescentic osteotomy that were fixed using a single screw demonstrated higher mean failure moments than pairs that were fixed with four staples or two K wires; staples were the weakest construct. All specimens fixed with staples failed by bending of the staples without bony fracture; all K wire constructs but one failed by wire bending. Chevron and crescentic osteotomies fixed with a single screw demonstrated equal bending strengths; the bending strength of an oblique osteotomy fixed with two screws was 82% greater than for a crescentic osteotomy fixed with a single screw. Basilar osteotomies of the first metatarsal are useful in correcting metatarsus primus varus often associated with hallux valgus pathology. Fixation strength is an important consideration since weightbearing forces on the head of the first metatarsal acting at a distance from the osteotomy site subject the construct to a dorsiflexion bending moment, as simulated in our tests. Our results show that screw fixation is the strongest method for stabilizing a basilar osteotomy. Based upon the relatively low bending strengths of the staple and K wire constructs, we would not recommend these forms of fixation.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Dental claims in the Swedish Patient Insurance Scheme.

    PubMed

    René, N; Owall, B; Cronström, R

    1991-06-01

    The Swedish Patient Insurance Scheme covers treatment injuries and guarantees the replacement of failed removable prostheses for 1 year and fixed prostheses for 2 years after fitting. In this paper, 573 dental cases are analysed for a 3-month period in 1986, during which crowns and bridges formed the vast majority of failed treatments that were reported.

  5. Immediate occlusal loading of NanoTite PREVAIL implants: a prospective 1-year clinical and radiographic study.

    PubMed

    Ostman, Pär-Olov; Wennerberg, Ann; Albrektsson, Tomas

    2010-03-01

    Recently, a new implant surface texture, featuring application of nanometer-scale calcium phosphate has been shown to enhance early bone fixation and formation in preclinical studies and in human histomorphometric studies, which may be beneficial in immediate loading situations. The purpose of the present prospective clinical study was to, during 1 year, clinically and radiographically evaluate a nanometer scale surface modified implant placed for immediate loading of fixed prostheses in both maxillary and mandibular regions. Thirty-five out of 38 patients who needed implant treatment and met inclusion criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 25 Ncm prior to final seating and an implant stability quotient above 55. A total of 102 NanoTite PREVAIL (NTP) implants (BIOMET 3i, Palm Beach Gardens, FL, USA) (66 maxillary and 36 mandibular) were placed by one investigator, and the majority of these were placed in posterior regions (65%) and in soft bone (69%). A total of 44 prosthetic constructions were evaluated consisting of 14 single-tooth restorations, 26 fixed partial dentures, and four complete fixed restorations. All provisional constructions were delivered within 1 hour, and the final constructions placed after 4 months. Implants were monitored for clinical and radiographic outcomes at follow-up examinations scheduled for 3, 6, and 12 months. Of the 102 study implants, one implant failed. The simple cumulative survival rate value at 1 year was 99.2%. The average marginal bone resorption was 0.37 mm (SD 0.39) during the first year in function. According to the success criteria of Albrektsson and Zarb, success grade 1 was found with 93% of the implants. Although limited to the short follow-up, immediate loading of NanoTite Prevail implants seems to be a viable option in implant rehabilitation, at least when a good initial fixation is achieved.

  6. Center for Advanced Bioengineering for Soldier Survivability

    DTIC Science & Technology

    2013-06-01

    useful products have been limited. This is in part because the technology development teams have failed to include clinicians and engineers...to useful products have been limited. This is in part because the technology development teams have failed to include clinicians and engineers...7, 14, 21, and 28 days. After 28 days the samples were explanted, fixed, and scanned for mineralized matrix using Micro -CT imaging. Some samples

  7. Syndrome of fixed dystonia in adolescents--short term outcome in 4 cases.

    PubMed

    Majumdar, Anirban; López-Casas, Jesús; Poo, Pilar; Colomer, Jaume; Galvan, Marta; Lingappa, Lokesh; Short, Clare; Jardine, Philip E; Fernández-Alvarez, Emilio

    2009-09-01

    We describe the clinical features, investigations and outcome of 4 adolescents aged 13, 16, 17 and 19 years, with fixed dystonia. The diagnosis was made within 6 months of the onset of symptoms. One patient had an identifiable traumatic precipitant. All the affected extremities had pain, sudomotor and vascular changes which were consistent with complex regional pain syndrome. The extremities affected by dystonia were the foot and the hand. The dystonia spread to affect other extremities in one patient. One patient had hemifacial spasm. Examination of the central and peripheral nervous system and allied investigations failed to reveal an organic cause. Common genetic causes for dystonia were excluded. The response to physical treatments for the affected extremities, such as Botulinum Toxin and surgery was poor. In all our cases there were significant psychological and psychiatric factors. Three patients fully met the criteria for psychogenic dystonia and responded well to psychological intervention. Fixed dystonia in adolescents is an uncommon disorder of unknown aetiology, usually presenting in girls, which can be very disabling and difficult to treat. The affected parts of the body are usually painful and show vascular changes. The condition is allied to CRPS. Treatment with multidisciplinary approach including psychological measures and physiotherapy is more likely to be successful and may prevent unnecessary physical measures.

  8. Outcome, transport times, and costs of patients evacuated by helicopter versus fixed-wing aircraft.

    PubMed Central

    Thomas, F.; Wisham, J.; Clemmer, T. P.; Orme, J. F.; Larsen, K. G.

    1990-01-01

    We determined the differences in transport times and costs for patients transported by fixed-wing aircraft versus helicopter at ranges of 101 to 150 radial miles, where fixed-wing and helicopter in-hospital transports commonly overlap. Statistical analysis failed to show a significant difference between the trauma-care patients transported by helicopter (n = 109) and those transported by fixed-wing (n = 86) for age, injury severity score, hospital length of stay, hospital mortality, or discharge disability score. The times in returning patients to the receiving hospital by helicopter (n = 104) versus fixed-wing (n = 509) did not differ significantly. Helicopter transport costs per mile ($24), however, were 400% higher than those of fixed-wing aircraft with its associated ground ambulance transport costs ($6). Thus, helicopter transport is economically unjustified for interhospital transports exceeding 100 radial miles when an efficient fixed-wing service exists. PMID:2389575

  9. Brain dead or not? CT angiogram yielding false-negative result on brain death confirmation.

    PubMed

    Johnston, Robyn; Kaliaperumal, Chandrasekaran; Wyse, Gerald; Kaar, George

    2013-01-08

    We describe a case of severe traumatic brain injury with multiple facial and skull fractures where CT angiogram (CTA) failed to yield a definite result of brain death as an ancillary test. A 28-year-old man was admitted following a road traffic accident with a Glasgow Coma Score (GCS) of 3/15 and fixed pupils. CT brain revealed uncal herniation and diffuse cerebral oedema with associated multiple facial and skull fractures. 72 h later, his clinical condition remained the same with high intracranial pressure refractory to medical management. Clinical confirmation on brain death was not feasible owing to facial injuries. A CTA, performed to determine brain perfusion, yielded a 'false-negative' result. Skull fractures have possibly led to venous prominence in the cortical and deep venous drainage system. This point needs to be borne in mind while considering CTA as an ancillary test to confirm brain death.

  10. Brain dead or not? CT angiogram yielding false-negative result on brain death confirmation

    PubMed Central

    Johnston, Robyn; Kaliaperumal, Chandrasekaran; Wyse, Gerald; Kaar, George

    2013-01-01

    We describe a case of severe traumatic brain injury with multiple facial and skull fractures where CT angiogram (CTA) failed to yield a definite result of brain death as an ancillary test. A 28-year-old man was admitted following a road traffic accident with a Glasgow Coma Score (GCS) of 3/15 and fixed pupils. CT brain revealed uncal herniation and diffuse cerebral oedema with associated multiple facial and skull fractures. 72 h later, his clinical condition remained the same with high intracranial pressure refractory to medical management. Clinical confirmation on brain death was not feasible owing to facial injuries. A CTA, performed to determine brain perfusion, yielded a ‘false-negative’ result. Skull fractures have possibly led to venous prominence in the cortical and deep venous drainage system. This point needs to be borne in mind while considering CTA as an ancillary test to confirm brain death. PMID:23302550

  11. Fractographic Analysis of a Dental Zirconia Framework: a Case Study on Design Issues

    PubMed Central

    Lohbauer, Ulrich; Amberger, Gudrun; Quinn, George D.; Scherrer, Susanne S.

    2011-01-01

    Fractographic analysis of clinically failed dental ceramics can provide insights as to the failure origin and related mechanisms. One anterior 6-unit all-ceramic zirconia fixed partial denture (FPD) (Cercon®) has been clinically recovered and examined using qualitative fractography. The purpose was to identify the fracture origin and to state the reasons for failure. The recovered parts of the zirconia FPD were microscopically examined to identify classic fractographic patterns such as arrest lines, hackle, twist hackle and wake hackle. The direction of crack propagation was mapped and interpreted back to the origin of failure at the interface of the occlusalpalatal tip of the core and the veneering ceramic. An inappropriate core drop design favoring localized stress concentration combined with a pore cluster in the veneering ceramic at the core tip interface were the reasons for this premature through-the-core thickness failure. PMID:20826369

  12. Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties--a comparison between mobile bearing and fixed bearing knees.

    PubMed

    Huang, Chun-Hsiung; Ho, Fang-Yuan; Ma, Hon-Ming; Yang, Chan-Tsung; Liau, Jiann-Jong; Kao, Hung-Chan; Young, Tai-Horng; Cheng, Cheng-Kung

    2002-09-01

    Osteolysis induced by ultrahigh molecular weight polyethylene wear debris has been recognized as the major cause of long-term failure in total joint arthroplasties. In a previous study, the prevalence of intraoperatively identified osteolysis during primary revision surgery was much higher in mobile bearing knee replacements (47%) than in fixed bearing knee replacements (13%). We postulated that mobile bearing knee implants tend to produce smaller sized particles. In our current study, we compared the particle size and morphology of polyethylene wear debris between failed mobile bearing and fixed bearing knees. Tissue specimens from interfacial and lytic regions were extracted during revision surgery of 10 mobile bearing knees (all of the low contact stress (LCS) design) and 17 fixed bearing knees (10 of the porous-coated anatomic (PCA) and 7 of the Miller/Galante design). Polyethylene particles were isolated from the tissue specimens and examined using both scanning electron microscopy and light-scattering analyses. The LCS mobile bearing knees produced smaller particulate debris (mean equivalent spherical diameter: 0.58 microm in LCS, 1.17 microm in PCA and 5.23 microm in M/G) and more granular debris (mean value: 93% in LCS, 77% in PCA and 15% in M/G).

  13. The Case for Nation-building: Why and How to Fix Failed States

    DTIC Science & Technology

    2011-12-01

    Asia), pandemic disease (AIDS), and ecologi - cal disaster—to say nothing of the occasional global terrorist organization. Time and time again...borders. And piracy along the east coast of Africa has increased over the last two decades since Somalia’s collapse into anarchy . These threats...ignore the problems, allow anarchy to consume failed states, and pay ever higher costs to isolate themselves and repair any damage after the fact. But

  14. [Mixed states: evolution of classifications].

    PubMed

    Pringuey, D; Cherikh, F; Giordana, B; Fakra, E; Dassa, D; Cermolacce, M; Belzeaux, R; Maurel, M; Azorin, J-M

    2013-12-01

    The nosological position of mixed states has followed the course of classifying methods in psychiatry, the steps of the invention of the clinic, progress in the organization of care, including the discoveries of psychopharmacology. The clinical observation of a mixture of symptoms emerging from usually opposite clinical conditions is classical. In the 70s, a syndromic specification fixed the main symptom combinations but that incongruous assortment failed to stabilize the nosological concept. Then stricter criteriology was proposed. To be too restrictive, a consensus operates a dimensional opening that attempts to meet the pragmatic requirements of nosology validating the usefulness of the class system. This alternation between rigor of categorization and return to a more flexible criteriological option reflects the search for the right balance between nosology and diagnosis. The definition of mixed states is best determined by their clinical and prognostic severity, related to the risk of suicide, their lower therapeutic response, the importance of their psychiatric comorbidities, anxiety, emotional lability, alcohol abuse. Trying to compensate for the lack of categorical definitions and better reflecting the clinical field problems, new definitions complement criteriology with dimensional aspects, particularly taking into account temperaments. Copyright © 2013 L’Encéphale. Published by Elsevier Masson SAS.. All rights reserved.

  15. Evaluation of the long-term cost-effectiveness of IDegLira versus liraglutide added to basal insulin for patients with type 2 diabetes failing to achieve glycemic control on basal insulin in the USA.

    PubMed

    Hunt, B; Mocarski, M; Valentine, W J; Langer, J

    2017-07-01

    IDegLira, a fixed ratio combination of insulin degludec and glucagon-like peptide-1 receptor agonist liraglutide, utilizes the complementary mechanisms of action of these two agents to improve glycemic control with low risk of hypoglycemia and avoidance of weight gain. The aim of the present analysis was to assess the long-term cost-effectiveness of IDegLira vs liraglutide added to basal insulin, for patients with type 2 diabetes not achieving glycemic control on basal insulin in the US setting. Projections of lifetime costs and clinical outcomes were made using the IMS CORE Diabetes Model. Treatment effect data for patients receiving IDegLira and liraglutide added to basal insulin were modeled based on the outcomes of a published indirect comparison, as no head-to-head clinical trial data is currently available. Costs were accounted in 2015 US dollars ($) from a healthcare payer perspective. IDegLira was associated with small improvements in quality-adjusted life expectancy compared with liraglutide added to basal insulin (8.94 vs 8.91 discounted quality-adjusted life years [QALYs]). The key driver of improved clinical outcomes was the greater reduction in glycated hemoglobin associated with IDegLira. IDegLira was associated with mean costs savings of $17,687 over patient lifetimes vs liraglutide added to basal insulin, resulting from lower treatment costs and cost savings as a result of complications avoided. The present long-term modeling analysis found that IDegLira was dominant vs liraglutide added to basal insulin for patients with type 2 diabetes failing to achieve glycemic control on basal insulin in the US, improving clinical outcomes and reducing direct costs.

  16. Retrospective chart analysis on survival rate of fixtures installed at the tuberosity bone for cases with missing unilateral upper molars: a study of 7 cases.

    PubMed

    Park, Young-Jin; Cho, Sung-Am

    2010-06-01

    To evaluate the survival rate of implants placed in the maxillary tuberosity region using the fixed prosthesis in partially edentulous cases. Of implant-treated patients who visited Kyung Pook National University Hospital, 7 partially edentulous patients (2 male and 5 female; mean age, 52.3 years; range, approximately 43 to 65) were selected according to the following criteria: 1) less than 3-mm thickness alveolar bone reaming at the first molar area and 2) 1 to 2 fixture premolars, with the additional implant at the maxillary tuberosity region. For the control group, patients who had nontuberosity areas were selected. After 1 to 7 years, marginal bone level, fixture mobility, and radiolucency of tuberosity fixtures of the fixed prostheses were evaluated by digital panorama (Starpacs, Infinitt, Seoul, Korea). None of the fixtures of the tuberosity-installed implants for 1 to 7 years failed. The marginal bone level around the implants of the maxillary tuberosity 1 to 6 years (average 3.4 years) after the final prostheses was approximately 0.6 to 1.3 mm, with an average of 0.94 mm. The fixture installation at the maxillary tuberosity using the unilateral partially edentulous implant-fixed prosthesis would be a clinically acceptable treatment module. 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Success, clinical performance and patient satisfaction of direct fibre-reinforced composite fixed partial dentures - a two-year clinical study.

    PubMed

    Malmstrom, H; Dellanzo-Savu, A; Xiao, J; Feng, C; Jabeen, A; Romero, M; Huang, J; Ren, Y; Yunker, M A

    2015-12-01

    To evaluate the success, clinical performance and patient satisfaction of directly placed fibre-reinforced composite (FRC) fixed partial dentures (FPDs) in 2 years. One hundred sixty-seven FRC FPDs (120 subjects) were directly fabricated to restore a single missing tooth by six Advanced Education in General Dentistry (AEGD) residents. The FRC FPDs recipients were randomised into two groups according to the fibre materials (pre-impregnated glass or polyethylene). Clinical performance was evaluated at baseline (2 weeks), 6, 12 and 24 months by two calibrated evaluators for prosthesis adaptation, colour match, marginal discoloration, surface roughness, caries and post-operative sensitivity using modified United State Public Health Service (USPHS) criteria. Prosthesis appearance, colour, chewing ability and overall satisfaction were evaluated by patients using a visual analogue scale (VAS). Kaplan-Meier estimation was used to estimate the prosthesis success. Ninety-four patients with 137 FRC FPDs returned (21·67% attrition rate for study subjects, 17·94% for FRC FPDs). Seventeen FRC FPDs failed, due to one-end (n = 4) or two-ends (n = 4) debonding or pontic fracture (n = 9). The cumulative 2-year success rate was 84·32% and survival rate was 92·7%; there were no statistically significant differences between the groups according to different missing tooth location, retention type or fibre materials (P > 0·05). Patient satisfaction regarding prosthesis appearance, col-our, chewing ability and overall satisfaction was rated high on the VAS (mean >80 mm) for all criteria at all time points. The FRC FPDs (restoring single tooth) fabricated by AEGD residents achieved acceptable success and survival rates in a 2-year follow-up. © 2015 John Wiley & Sons Ltd.

  18. A Mind-Set Is a Difficult Thing to Change: Why Reforming Low-Performing Schools Requires Eradicating Negative Beliefs about Students. The Claremont Letter. Volume 2, Issue 3

    ERIC Educational Resources Information Center

    Thompson, Gail

    2007-01-01

    Numerous researchers have devoted their careers to school reform. At the same time, many politicians have gotten elected by promising to fix failing schools. Although a lot of time, energy, and money have been invested in tackling this problem, the problem persists: Too many schools in the United States are failing to prepare too many students for…

  19. Exploring a Method for Improving Turbulent Separated-Flow Predictions with kappa-omega Models

    NASA Technical Reports Server (NTRS)

    Rumsey, Christopher L.

    2009-01-01

    A particular failing of Reynolds-averaged Navier-Stokes separated turbulent flow computations is addressed within the context of a kappa-omega two-equation turbulence model. The failing is the tendency for turbulence models to under-predict turbulent shear stress in the shear layers of some separation bubbles, yielding late boundary layer reattachment and recovery. Inspired by unpublished work of Volker, Langtry, and Menter, the author undertook an independent investigation in an attempt to improve the ability of the Menter shear stress transport (SST) model to predict flowfield characteristics in and downstream of separation bubbles. The fix is an ad hoc term that is a function of the local ratio of turbulent production to dissipation; it is used to multiply the omega-destruction term, increasing eddy viscosity in separated regions. With this fix, several flowfields are investigated. Results show that, although the "separation fix" can provide dramatic improvement in some cases, it is not consistently good for all flows. Thus, although it may prove helpful in many situations in its current form, this model may benefit from further refinements, including better sensitization to the energetics of turbulence in the separated region.

  20. Narrow- (3.0 mm) Versus Standard-Diameter (4.0 and 4.5 mm) Implants for Splinted Partial Fixed Restoration of Posterior Mandibular and Maxillary Jaws: A 5-Year Retrospective Cohort Study.

    PubMed

    Pieri, Francesco; Forlivesi, Caterina; Caselli, Ernesto; Corinaldesi, Giuseppe

    2017-04-01

    Evidence concerning predictability of narrow-diameter implants (NDIs) (<3.3 mm) to restore partially edentulous posterior maxillary and mandibular areas is limited. The aim of this study is to compare the 5-year outcomes of NDIs (3.0 mm) and standard-diameter implants (SDIs) (4.0 to 4.5 mm) supporting fixed partial dentures (FPDs) in posterior mandibular and maxillary jaws. All patients treated with at least two adjacent NDIs or SDIs according to available bone thickness and with a minimum follow-up of 5 years after placement were invited to undergo a clinical and radiologic examination. Outcome measures were implant and FPD failures, biologic and prosthetic complications, and marginal bone loss. A total of 107 out of 127 patients attended the examination: 49 (113 implants) of the NDI group, and 58 (126 implants) of the SDI group. Two NDIs failed in one patient versus four SDIs in four patients (P = 0.37). One FPD failed in the NDI group versus two FPDs in the SDI group (P >0.99). Nine biologic complications occurred in the NDI group and twelve in the SDI group (P = 0.81). Twelve prosthetic complications occurred in the NDI group and only two in the SDI group (P = 0.001). Peri-implant marginal bone loss at 5 years was 0.95 ± 0.84 mm for the NDI group and 1.2 ± 0.86 mm for the SDI group (P = 0.06). Five-year data indicate that FPD treatment in posterior mandibular and maxillary jaws with NDIs was as reliable as with SDIs, although NDIs showed a higher risk of prosthetic complications.

  1. Young investigator challenge: Validation and optimization of immunohistochemistry protocols for use on cellient cell block specimens.

    PubMed

    Sauter, Jennifer L; Grogg, Karen L; Vrana, Julie A; Law, Mark E; Halvorson, Jennifer L; Henry, Michael R

    2016-02-01

    The objective of the current study was to establish a process for validating immunohistochemistry (IHC) protocols for use on the Cellient cell block (CCB) system. Thirty antibodies were initially tested on CCBs using IHC protocols previously validated on formalin-fixed, paraffin-embedded tissue (FFPE). Cytology samples were split to generate thrombin cell blocks (TCB) and CCBs. IHC was performed in parallel. Antibody immunoreactivity was scored, and concordance or discordance in immunoreactivity between the TCBs and CCBs for each sample was determined. Criteria for validation of an antibody were defined as concordant staining in expected positive and negative cells, in at least 5 samples each, and concordance in at least 90% of the samples total. Antibodies that failed initial validation were retested after alterations in IHC conditions. Thirteen of the 30 antibodies (43%) did not meet initial validation criteria. Of those, 8 antibodies (calretinin, clusters of differentiation [CD] 3, CD20, CDX2, cytokeratin 20, estrogen receptor, MOC-31, and p16) were optimized for CCBs and subsequently validated. Despite several alterations in conditions, 3 antibodies (Ber-EP4, D2-40, and paired box gene 8 [PAX8]) were not successfully validated. Nearly one-half of the antibodies tested in the current study failed initial validation using IHC conditions that were established in the study laboratory for FFPE material. Although some antibodies subsequently met validation criteria after optimization of conditions, a few continued to demonstrate inadequate immunoreactivity. These findings emphasize the importance of validating IHC protocols for methanol-fixed tissue before clinical use and suggest that optimization for alcohol fixation may be needed to obtain adequate immunoreactivity on CCBs. © 2016 American Cancer Society.

  2. Clinical acceptability of metal-ceramic fixed partial dental prosthesis fabricated with direct metal laser sintering technique-5 year follow-up.

    PubMed

    Prabhu, Radhakrishnan; Prabhu, Geetha; Baskaran, Eswaran; Arumugam, Eswaran M

    2016-01-01

    In recent years, direct metal laser sintered (DMLS) metal-ceramic-based fixed partial denture prostheses have been used as an alternative to conventional metal-ceramic fixed partial denture prostheses. However, clinical studies for evaluating their long-term clinical survivability and acceptability are limited. The aim of this study was to assess the efficacy of metal-ceramic fixed dental prosthesis fabricated with DMLS technique, and its clinical acceptance on long-term clinical use. The study group consisted of 45 patients who were restored with posterior three-unit fixed partial denture prosthesis made using direct laser sintered metal-ceramic restorations. Patient recall and clinical examination of the restorations were done after 6months and every 12 months thereafter for the period of 60 months. Clinical examination for evaluation of longevity of restorations was done using modified Ryge criteria which included chipping of the veneered ceramic, connector failure occurring in the fixed partial denture prosthesis, discoloration at the marginal areas of the veneered ceramic, and marginal adaptation of the metal and ceramic of the fixed denture prosthesis. Periapical status was assessed using periodical radiographs during the study period. Survival analysis was made using the Kaplan-Meier method. None of the patients had failure of the connector of the fixed partial denture prostheses during the study period. Two exhibited biological changes which included periapical changes and proximal caries adjacent to the abutments. DMLS metal-ceramic fixed partial denture prosthesis had a survival rate of 95.5% and yielded promising results during the 5-year clinical study.

  3. Health economic analyses of domiciliary dental care and care at fixed clinics for elderly nursing home residents in Sweden.

    PubMed

    Lundqvist, M; Davidson, T; Ordell, S; Sjöström, O; Zimmerman, M; Sjögren, P

    2015-03-01

    Dental care for elderly nursing home residents is traditionally provided at fixed dental clinics, but domiciliary dental care is an emerging alternative. Longer life expectancy accompanied with increased morbidity, and hospitalisation or dependence on the care of others will contribute to a risk for rapid deterioration of oral health so alternative methods for delivering oral health care to vulnerable individuals for whom access to fixed dental clinics is an obstacle should be considered. The aim was to analyse health economic consequences of domiciliary dental care for elderly nursing home residents in Sweden, compared to dentistry at a fixed clinic. A review of relevant literature was undertaken complemented by interviews with nursing home staff, officials at county councils, and academic experts in geriatric dentistry. Domiciliary dental care and fixed clinic care were compared in cost analyses and cost-effectiveness analyses. The mean societal cost of domiciliary dental care for elderly nursing home residents was lower than dental care at a fixed clinic, and it was also considered cost-effective. Lower cost of dental care at a fixed dental clinic was only achieved in a scenario where dental care could not be completed in a domiciliary setting. Domiciliary dental care for elderly nursing home residents has a lower societal cost and is cost-effective compared to dental care at fixed clinics. To meet current and predicted need for oral health care in the ageing population alternative methods to deliver dental care should be available.

  4. Clinical acceptability of metal-ceramic fixed partial dental prosthesis fabricated with direct metal laser sintering technique-5 year follow-up

    PubMed Central

    Prabhu, Radhakrishnan; Prabhu, Geetha; Baskaran, Eswaran; Arumugam, Eswaran M.

    2016-01-01

    Statement of Problem: In recent years, direct metal laser sintered (DMLS) metal-ceramic-based fixed partial denture prostheses have been used as an alternative to conventional metal-ceramic fixed partial denture prostheses. However, clinical studies for evaluating their long-term clinical survivability and acceptability are limited. Aims and Objective: The aim of this study was to assess the efficacy of metal-ceramic fixed dental prosthesis fabricated with DMLS technique, and its clinical acceptance on long-term clinical use. Materials and Methods: The study group consisted of 45 patients who were restored with posterior three-unit fixed partial denture prosthesis made using direct laser sintered metal-ceramic restorations. Patient recall and clinical examination of the restorations were done after 6months and every 12 months thereafter for the period of 60 months. Clinical examination for evaluation of longevity of restorations was done using modified Ryge criteria which included chipping of the veneered ceramic, connector failure occurring in the fixed partial denture prosthesis, discoloration at the marginal areas of the veneered ceramic, and marginal adaptation of the metal and ceramic of the fixed denture prosthesis. Periapical status was assessed using periodical radiographs during the study period. Survival analysis was made using the Kaplan–Meier method. Results: None of the patients had failure of the connector of the fixed partial denture prostheses during the study period. Two exhibited biological changes which included periapical changes and proximal caries adjacent to the abutments. Conclusion: DMLS metal-ceramic fixed partial denture prosthesis had a survival rate of 95.5% and yielded promising results during the 5-year clinical study. PMID:27141171

  5. A 4-year clinical evaluation of direct composite build-ups for space closure after orthodontic treatment.

    PubMed

    Demirci, Mustafa; Tuncer, Safa; Öztaş, Evren; Tekçe, Neslihan; Uysal, Ömer

    2015-12-01

    To evaluate the medium-term clinical performance of direct composite build-ups for diastema closures and teeth recontouring using a nano and a nanohybrid composite in combination with three- or two-step etch-and-rinse adhesives following treatment with fixed orthodontic appliances. A total of 30 patients (mean age, 19.5 years) received 147 direct composite additions for teeth recontouring and diastema closures. A nano and a nanohybrid composite (Filtek Supreme XT and CeramX Duo) were bonded to tooth structure by using a three-step (Scotchbond Multipurpose) or a two-step (XP Bond) etch and rinse adhesive. Ten out of 147 composite build-ups (composite addition) constituted tooth recontouring cases, and the remaining 137 constituted diastema closure cases. The restorations were evaluated by two experienced, calibrated examiners according to modified Ryge criteria at the following time intervals: baseline, 1, 2, 3, and 4 years. The 4-year survival rates were 92.8 % for Filtek Supreme XT/Scotchbond Multi-Purpose Plus and 93 % for CeramX Duo/XP Bond. Only ten restorations failed (5 Filtek Supreme XT and 5 CeramX Duo). Statistical analysis revealed no significant differences between the two composite-adhesive combinations with respect to color match, marginal discoloration, wear/loss of anatomical form, caries formation, marginal adaptation, and surface texture on comparing the five time periods (baseline, 1, 2, 3, and 4 years) The 4-year survival rates in the present study were favorable. The restorations exhibited excellent scores with regard to color match, marginal adaptation, surface texture, marginal discoloration, wear/loss of anatomical form, and caries formation, after 4 years of clinical evaluation. Clinical relevance An alternative clinical approach for correcting discrepancies in tooth size and form, such as performing direct composite restorations following fixed orthodontic treatment, may be an excellent and minimally invasive treatment.

  6. Phentermine and topiramate for the management of obesity: a review

    PubMed Central

    Cosentino, Gina; Conrad, Ariane O; Uwaifo, Gabriel I

    2013-01-01

    Obesity is now a major public health concern worldwide with increasing prevalence and a growing list of comorbidities and complications. The morbidity, mortality and reduced productivity associated with obesity and its complications result in a major burden to health care costs. Obesity is a complex chronic medical syndrome often with multiple different etiologic factors in individual patients. The long term successful management of obesity remains particularly challenging and invariably requires a multifaceted approach including lifestyle and behavioral modification, increased physical activity, and adjunctive pharmacotherapy. Bariatric surgery remains a last resort though at present it has the best results for achieving sustained robust weight loss. Obesity pharmacotherapy has been very limited in its role for long term obesity management because of the past history of several failed agents as well as the fact that presently available agents are few, and generally utilized as monotherapy. The recent FDA approval of the fixed drug combination of phentermine and extended release topiramate (topiramate-ER) (trade name Qsymia™) marks the first FDA approved combination pharmacotherapeutic agent for obesity since the Phen-Fen combination of the 1990s. This review details the history and clinical trial basis for the use of both phentermine and topiramate in obesity therapeutics as well as the results of clinical trials of their combination for obesity treatment in humans. The initial clinical approval trials offer evidence that this fixed drug combination offers synergistic potential for effective, robust and sustained weight loss with mean weight loss of at least 10% of baseline achieved and sustained for up to 2 years in over 50% of subjects treated. It is anticipated that this agent will be the first in a new trend of multi-agent combination therapy for the chronic adjunctive management of obesity. PMID:23630412

  7. Addition of a suture anchor for coracoclavicular fixation to a superior locking plate improves stability of type IIB distal clavicle fractures.

    PubMed

    Madsen, Wes; Yaseen, Zaneb; LaFrance, Russell; Chen, Tony; Awad, Hani; Maloney, Michael; Voloshin, Ilya

    2013-06-01

    The purpose of this study was to determine the effect of coracoclavicular (CC) fixation on biomechanical stability in type IIB distal clavicle fractures fixed with plate and screws. Twelve fresh-frozen matched cadaveric specimens were used to create type IIB distal clavicle fractures. Dual-energy x-ray absorptiometry (DEXA) scans ensured similar bone quality. Group 1 (6 specimens) was stabilized with a superior precontoured distal clavicle locking plate and supplemental suture anchor CC fixation. Group 2 (6 specimens) followed the same construct without CC fixation. Each specimen was cyclically loaded in the coronal plane at 40 to 80 N for 17,500 cycles. Load-to-failure testing was performed on the specimens that did not fail cyclic loading. Outcome measures included mode of failure and the number of cycles or load required to create 10 mm of displacement in the construct. All specimens (12 of 12) completed cyclic testing without failure and underwent load-to-failure testing. Group 1 specimens failed at a mean of 808.5 N (range, 635.4 to 952.3 N), whereas group 2 specimens failed at a mean of 401.3 N (range, 283.6 to 656.0 N) (P = .005). Group 1 specimens failed by anchor pullout without coracoid fracture (4 of 6) and distal clavicle fracture fragment fragmentation (1 of 6); one specimen did not fail at the maximal load the materials testing machine was capable of exerting (1,000 N). Group 2 specimens failed by distal clavicle fracture fragment fragmentation (3 of 6) and acromioclavicular (AC) joint displacement (1 of 6); 2 specimens did not fail at the maximal load of the materials testing machine. During cyclic loading, type IIB distal clavicle fractures with and without CC fixation remain stable. CC fixation adds stability to type IIB distal clavicle fractures fixed with plate and screws when loaded to failure. CC fixation for distal clavicle fractures is a useful adjunct to plate-and-screw fixation to augment stability of the fracture. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Clinical and Radiographic Assessment of Three-Implant-Supported Fixed-Prosthesis Rehabilitation of the Edentulous Mandible: Immediate Versus Delayed Loading.

    PubMed

    Primo, Bruno Tochetto; Mezzari, Leonardo Marcos; da Fontoura Frasca, Luís Carlos; Linderman, Raquel; Rivaldo, Elken Gomes

    To evaluate and compare the clinical and radiographic outcomes of mandibular rehabilitation with fixed prostheses on three implants with immediate versus delayed loading. The sample comprised 21 patients who underwent treatment with immediate loading and 23 who received delayed loading. All had worn their prostheses for at least 18 months. Radiographic evaluation of bone loss was carried out in Adobe Photoshop CS5 by a single calibrated examiner using digitized panoramic radiographs. Clinical examination of the technical conditions of the prosthetic device assessed the condition of the acrylic resin base, dental occlusion, metal framework, presence of cover screws, screw fixation of the prosthesis and abutments, length of cantilever (effort) and resistance arms, presence of plaque on prosthetic abutments, and hygiene of the prosthesis. One implant failed in each group, resulting in a 95.23% treatment success rate with immediate loading and 95.65% with delayed loading (no statistically significant between-group difference). In the immediate-loading group, the mean bone loss was 1.96 ± 0.73 mm around central implants and 1.64 ± 0.84 mm at distal implants. In the delayed-loading group, the mean bone loss was 1.85 ± 0.67 mm around central implants and 1.70 ± 0.77 mm at distal implants. According to Student t test, there was no significant within-group difference in bone loss and no difference between the immediate-loading and delayed-loading groups. The only prosthesis-related complications that differed significantly between groups were "condition of the acrylic base," "occlusion," and "presence of right cover screw." There was no statistically significant association of lever arm ratio with peri-implant bone loss or bone loss on the mesial surfaces compared to the distal surfaces of the distal implants. The three-implant-supported fixed prosthesis protocol tested in this study proved to be a viable therapeutic strategy for mandibular edentulous patients with maxillary complete dentures, regardless of whether loading was immediate or delayed, with no difference in peri-implant bone loss.

  9. Manual Override For Electromechanical Latch

    NASA Technical Reports Server (NTRS)

    Scott, Richard

    1992-01-01

    Override mechanism enables user to operate electromechanical latching mechanism manually if primary mechanism fails. Release/Engage Mechanism (REM) moves pin receivers to confine pins on object to be held. Clutch disengages electrically driven latch normally used. Used to latch and unlatch large, heavy objects from fixed support structure.

  10. Dynamics of a b-nut failure

    NASA Astrophysics Data System (ADS)

    Zarubin, Peter V.

    1999-06-01

    In August of 1989, the Galileo spacecraft, consisting of an orbiter and probe, was mounted to an Inertial Upper Stage (IUS) rocket stage being readied for flight aboard NASA's Space Shuttle, 'STS-34,' 'Atlantis.' During routine age testing of an IUS igniter fire line circuit, a 'b-nut' failure occurred. On board the Galileo/IUS first stage rocket motor was a b-nut from this failed lot. There was concern that the mission could be jeopardized if the b-nut failed because of the close proximity of the IUS second stage rocket motor nozzle. A fix had to be made to insure mission success. Chemical Systems Division was called upon to provide high- speed motion picture photography at 3000 frames per second to analyze the dynamics of a b-nut failure, and verify that the fix would prevent damage to the second stage nozzle, should a b-nut failure occur. This report will show how displacement and velocity measurements can be made from 16 mm motion picture film.

  11. Precise Point Positioning with Partial Ambiguity Fixing.

    PubMed

    Li, Pan; Zhang, Xiaohong

    2015-06-10

    Reliable and rapid ambiguity resolution (AR) is the key to fast precise point positioning (PPP). We propose a modified partial ambiguity resolution (PAR) method, in which an elevation and standard deviation criterion are first used to remove the low-precision ambiguity estimates for AR. Subsequently the success rate and ratio-test are simultaneously used in an iterative process to increase the possibility of finding a subset of decorrelated ambiguities which can be fixed with high confidence. One can apply the proposed PAR method to try to achieve an ambiguity-fixed solution when full ambiguity resolution (FAR) fails. We validate this method using data from 450 stations during DOY 021 to 027, 2012. Results demonstrate the proposed PAR method can significantly shorten the time to first fix (TTFF) and increase the fixing rate. Compared with FAR, the average TTFF for PAR is reduced by 14.9% for static PPP and 15.1% for kinematic PPP. Besides, using the PAR method, the average fixing rate can be increased from 83.5% to 98.2% for static PPP, from 80.1% to 95.2% for kinematic PPP respectively. Kinematic PPP accuracy with PAR can also be significantly improved, compared to that with FAR, due to a higher fixing rate.

  12. Precise Point Positioning with Partial Ambiguity Fixing

    PubMed Central

    Li, Pan; Zhang, Xiaohong

    2015-01-01

    Reliable and rapid ambiguity resolution (AR) is the key to fast precise point positioning (PPP). We propose a modified partial ambiguity resolution (PAR) method, in which an elevation and standard deviation criterion are first used to remove the low-precision ambiguity estimates for AR. Subsequently the success rate and ratio-test are simultaneously used in an iterative process to increase the possibility of finding a subset of decorrelated ambiguities which can be fixed with high confidence. One can apply the proposed PAR method to try to achieve an ambiguity-fixed solution when full ambiguity resolution (FAR) fails. We validate this method using data from 450 stations during DOY 021 to 027, 2012. Results demonstrate the proposed PAR method can significantly shorten the time to first fix (TTFF) and increase the fixing rate. Compared with FAR, the average TTFF for PAR is reduced by 14.9% for static PPP and 15.1% for kinematic PPP. Besides, using the PAR method, the average fixing rate can be increased from 83.5% to 98.2% for static PPP, from 80.1% to 95.2% for kinematic PPP respectively. Kinematic PPP accuracy with PAR can also be significantly improved, compared to that with FAR, due to a higher fixing rate. PMID:26067196

  13. A Systematic Review of Outcome Measurements and Quality of Studies Evaluating Fixed Tooth-Supported Restorations

    PubMed Central

    Patel, Devangkumar Rajnikant; O'Brien, Tim; Petrie, Aviva; Petridis, Haralampos

    2014-01-01

    Purpose The purpose of this systematic review was to review clinical studies of fixed tooth-supported prostheses, and to assess the quality of evidence with an emphasis on the assessment of the reporting of outcome measurements. Multiple hypotheses were generated to compare the effect of study type on different outcome modifiers and to compare the quality of publications before and after January 2005. Materials and Methods An electronic search was conducted using specific databases (MEDLINE via Ovid, EMBASE via Ovid, Cochrane Library) through July 2012. This was complemented by hand searching the past 10 years of issues of the Journal of Oral Rehabilitation, Journal of Prosthetic Dentistry, Journal of Prosthodontics, and the International Journal of Prosthodontics. All experimental and observational clinical studies evaluating survival, success, failure, and complications of tooth-supported extracoronal fixed partial dentures, crowns, and onlays were included. No restrictions on age or follow-up time were placed. Results The electronic search generated 14,869 papers, of which 206 papers were included for full-text review. Hand-searching added 23 papers. Inclusion criteria were met by 182 papers and were included for the review. The majority were retrospective studies. Only 8 (4.4%) were randomized controlled trials. The majority of the studies measured survival and failure, and few studies recorded data on success; however, more than 60% of the studies failed to define survival, success, and failure. Many studies did not use any standardized criteria for assessment of the quality of the restorations and, when standardized criteria were used, they were modified, thereby not allowing for comparisons with other studies. There was an increase of 21.8% in the number of studies evaluating outcome measurements of all-ceramic restorations in past 8 years. Conclusions Prosthodontic literature presents with a reduced percentage of RCTs compared to other disciplines in dentistry. The overall quality of recording prosthodontic outcome measurements has not improved greatly in the past 8 years. PMID:24947268

  14. A review of the new GLP-1 receptor agonist/basal insulin fixed-ratio combination products.

    PubMed

    Nuffer, Wesley; Guesnier, Ashley; Trujillo, Jennifer M

    2018-03-01

    There have been several new treatment approaches established for the management of hyperglycemia in type 2 diabetes (T2D), with treatment guidelines listing both glucagon-like peptide 1 receptor agonists (GLP-1 RAs) and basal insulin therapies as considerations for patients who have failed to control their blood glucose with oral antidiabetic agents. New studies have highlighted the importance of initiating combination therapy earlier in the T2D disease process to avoid clinical inertia and prevent the long-term complications arising from uncontrolled diabetes. Until recently, both GLP-1 RAs and basal insulin therapies were only available as single agents, but there are now two combination pen devices that deliver both a GLP-1 RA and basal insulin simultaneously. This article reviews the current clinical evidence evaluating the use of these combination GLP-1 RA/basal insulin preparations to treat T2D, presents both potential benefits as well as possible downsides with the use of these agents, and discusses the current place in therapy these products represent in the management of T2D.

  15. Becoming Chemists through Game-Based Inquiry Learning: The Case of "Legends of Alkhimia"

    ERIC Educational Resources Information Center

    Chee, Yam San; Tan, Kim Chwee Daniel

    2012-01-01

    Traditional modes of chemistry education in schools focus on imparting chemistry knowledge to students via instruction. Consequently, students often acquire the mistaken understanding that scientific knowledge comprises a fixed body of "proven" facts. They fail to comprehend that the construction of scientific understanding is a human…

  16. Importing Leaders for School Turnarounds: Lessons and Opportunities

    ERIC Educational Resources Information Center

    Kowal, Julie; Hassel, Emily Ayscue

    2011-01-01

    One of the biggest challenges in education today is identifying talented candidates to successfully lead turnarounds of persistently low-achieving schools. Evidence suggests that the traditional principal pool is already stretched to capacity and cannot supply enough leaders to fix failing schools. But potentially thousands of leaders capable of…

  17. Failing Boys? Issues in Gender and Achievement.

    ERIC Educational Resources Information Center

    Epstein, Debbie, Ed.; Elwood, Jannette, Ed.; Hey, Valerie, Ed.; Maw, Janet, Ed.

    Issues surrounding boys'"underachievement" have been at the center of public debate about education and the raising of standards in recent years. Media and political responses to the "problem of boys" have tended to be simplistic, partial, and owe more to quick fixes than investigation and research. This book provides a…

  18. Is There Evidence of Failing to Fail in Our Schools of Nursing?

    PubMed

    Docherty, Angie; Dieckmann, Nathan

    2015-01-01

    To assess evidence for "failing to fail" in undergraduate nursing programs. Literature on grading practices largely focuses on clinical or academic grading. Reviewing both as distinct entities may miss a more systemic grading problem. A cross-sectional survey targeted 235 faculty within university and community colleges in a western state. Chi-square tests of independence explored the relation between institutional and faculty variables. The response rate was 34 percent. Results suggest failing to fail may be evident across the sector in both clinical and academic settings: 43 percent of respondents had awarded higher grades than merited; 17.7 percent had passed written examinations they felt should fail; 66 percent believed they had worked with students who should not have passed their previous placement. Failing to fail cuts across instructional settings. Further exploration is imperative if schools are to better engender a climate for rigorously measuring student attainment.

  19. Finally, fixing health care: what's different now?

    PubMed

    Wyden, Ron; Bennett, Bob

    2008-01-01

    Is now the time to fix the U.S. health care system? Those who remember the failed attempts of the past would say no. We see it differently. Our optimism is rooted in new developments that didn't exist the last time Congress addressed health care. These include bipartisan support for our Healthy Americans Act; an ideological truce over the role of government in health care; common ground between business and labor; the realization that states can't go it alone on health care; the plight of employers in a global marketplace; and the need for coverage that is affordable, accessible, and portable.

  20. Planning multiple movements within a fixed time limit: The cost of constrained time allocation in a visuo-motor task

    PubMed Central

    Zhang, Hang; Wu, Shih-Wei; Maloney, Laurence T.

    2010-01-01

    S.-W. Wu, M. F. Dal Martello, and L. T. Maloney (2009) evaluated subjects' performance in a visuo-motor task where subjects were asked to hit two targets in sequence within a fixed time limit. Hitting targets earned rewards and Wu et al. varied rewards associated with targets. They found that subjects failed to maximize expected gain; they failed to invest more time in the movement to the more valuable target. What could explain this lack of response to reward? We first considered the possibility that subjects require training in allocating time between two movements. In Experiment 1, we found that, after extensive training, subjects still failed: They did not vary time allocation with changes in payoff. However, their actual gains equaled or exceeded the expected gain of an ideal time allocator, indicating that constraining time itself has a cost for motor accuracy. In a second experiment, we found that movements made under externally imposed time limits were less accurate than movements made with the same timing freely selected by the mover. Constrained time allocation cost about 17% in expected gain. These results suggest that there is no single speed–accuracy tradeoff for movement in our task and that subjects pursued different motor strategies with distinct speed–accuracy tradeoffs in different conditions. PMID:20884550

  1. THE EFFECTS OF FIXED VERSUS ESCALATING REINFORCEMENT SCHEDULES ON SMOKING ABSTINENCE

    PubMed Central

    Romanowich, Paul; Lamb, R. J.

    2015-01-01

    Studies indicate that when abstinence is initiated, escalating reinforcement schedules maintain continuous abstinence longer than fixed reinforcement schedules. However, these studies were conducted for shorter durations than most clinical trials and also resulted in larger reinforcer value for escalating participants during the 1st week of the experiment. We tested whether escalating reinforcement schedules maintained abstinence longer than fixed reinforcement schedules in a 12-week clinical trial. Smokers (146) were randomized to an escalating reinforcement schedule, a fixed reinforcement schedule, or a control condition. Escalating reinforcement participants received $5.00 for their first breath carbon monoxide (CO) sample <3 ppm, with a $0.50 increase for each consecutive sample. Fixed reinforcement participants received $19.75 for each breath CO sample <3 ppm. Control participants received payments only for delivering a breath CO sample. Similar proportions of escalating and fixed reinforcement participants met the breath CO criterion at least once. Escalating reinforcement participants maintained criterion breath CO levels longer than fixed reinforcement and control participants. Similar to previous short-term studies, escalating reinforcement schedules maintained longer durations of abstinence than fixed reinforcement schedules during a clinical trial. PMID:25640764

  2. Inferior Blueberries and Other Excuses I've Heard

    ERIC Educational Resources Information Center

    Van Winkle, David

    2005-01-01

    In this article, the author relates the blueberry story, as one of many excuses for barely advancing the status quo, and suggests a workable framework that is common to both education and business. Unfortunately, many business and education leaders seem intent on fixing specific issues and fail to acquire a systemic perspective. These isolated…

  3. Fixing High Schools

    ERIC Educational Resources Information Center

    Perkins-Gough, Deborah

    2005-01-01

    Reports from national education organizations in the US indicate the sorry state of high schools in the country that are accused of failing to adequately prepare their graduates for college or for the workforce, highlighting what is a serious problem in light of the troubled state of the US economy. The need to improve high schools is urgent and…

  4. 76 FR 77861 - Self-Regulatory Organizations; Fixed Income Clearing Corporation; Order Approving Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-14

    ... Treasury Markets Practices Group (the ``TMPG''), a group of market participants active in the Treasury securities market sponsored by the Federal Reserve Bank of New York (the ``FRBNY''), has been addressing the... interest rates. To encourage market participants to resolve fails promptly, the TMPG recommended expanding...

  5. Rocket Fuel R and D at AFRL: Recent Activities and Future Direction

    DTIC Science & Technology

    2017-04-12

    Clearance Number 17163 Rocket Cycles and Environments SpaceX Merlin 1D 190 klbf Russian RD-180 860 klbf Gas Generator Cycle Ox-Rich Staged Combustion...affordability & reusability • Modeling & Simulation • Key to development • Requires accurate models “CFD simulations… shorten the test-fail-fix loop” SpaceX

  6. Evidence for Student-Centered Learning

    ERIC Educational Resources Information Center

    Kaput, Krista

    2018-01-01

    For the past 35 years, the prevailing narrative about America's public education system is that it is "broken." Reform efforts have failed to find a fix because they fundamentally misunderstand this reality: the system is not broken. It is doing exactly what it was designed to do--educate the masses in a standardized fashion that…

  7. Assessing the overall benefit of a medication: cumulative benefit of secukinumab over time in patients with moderate-to-severe plaque psoriasis.

    PubMed

    Armstrong, April W; Feldman, Steven R; Korman, Neil J; Meng, Xiangyi; Guana, Adriana; Nyirady, Judit; Herrera, Vivian; Zhao, Yang

    2017-05-01

    Conventional measurements for assessing psoriasis treatment effects capture improvements at fixed, pre-specified timepoints, failing to account for cumulative clinical benefit over time. Explore the innovative concept of "cumulative clinical benefit" by examining the effect of secukinumab over 52 weeks in moderate-to-severe psoriasis patients. Cumulative clinical benefit was determined as the area-under-the-curve of the percentage of responders over 52 weeks (AUC 0-52 wks ), using pooled data from two phase III trials for patients receiving secukinumab (300 or 150 mg) or etanercept. Normalized cumulative benefit with secukinumab 300 mg, secukinumab 150 mg, and etanercept was 74.2%, 63.2%, and 50.5%, respectively, for PASI 75; 58.0%, 42.5%, and 29.5%, respectively, for PASI 90; 32.3%, 18.8%, and 8.7%, respectively, for PASI 100; and 58.3%, 47.9%, and 38.3%, respectively, for DLQI 0/1. 52-week PASI 75 clinical benefit ratios for secukinumab 300 and 150 mg versus etanercept were 1.47 and 1.25, respectively; the ratio of the two secukinumab doses was 1.17, favoring 300 mg. Post hoc analysis. Cumulative clinical benefit estimated by AUC 0-52 wks is a novel measure for comparing psoriasis treatments. Secukinumab 300 mg provides greater cumulative clinical benefit than secukinumab 150 mg; both provide greater cumulative benefit than etanercept.

  8. Use of an Orientation Clinic to Reduce Failed New Patient Appointments in Primary Care

    PubMed Central

    Jain, Sharad; Chou, Calvin L

    2000-01-01

    Patients who fail to attend initial appointments reduce clinic efficiency. To maximize attendance by newly referred outpatients, we introduced a mandatory group orientation clinic for all new patients and determined its effects on no-show rates. Orientation clinic also provided health care screening and opportunities for patient feedback. The new patient no-show rate for initial provider visits decreased significantly from 45% before institution of orientation clinic to 18% afterwards (P < .0001). The total no-show (patients who failed to attend orientation clinic or an initial provider visit) rate of the postintervention group was 51% (P = .28, compared with before the intervention). This intervention improved the efficiency and minimized the wasted time of our clinicians. PMID:11119184

  9. Tailoring treatment of haemophilia B: accounting for the distribution and clearance of standard and extended half-life FIX concentrates.

    PubMed

    Iorio, Alfonso; Fischer, Kathelijn; Blanchette, Victor; Rangarajan, Savita; Young, Guy; Morfini, Massimo

    2017-06-02

    The prophylactic administration of factor IX (FIX) is considered the most effective treatment for haemophilia B. The inter-individual variability and complexity of the pharmacokinetics (PK) of FIX, and the rarity of the disease have hampered identification of an optimal treatment regimens. The recent introduction of extended half-life recombinant FIX molecules (EHL-rFIX), has prompted a thorough reassessment of the clinical efficacy, PK and pharmacodynamics of plasma-derived and recombinant FIX. First, using longer sampling times and multi-compartmental PK models has led to more precise (and favourable) PK for FIX than was appreciated in the past. Second, investigating the distribution of FIX in the body beyond the vascular space (which is implied by its complex kinetics) has opened a new research field on the role for extravascular FIX. Third, measuring plasma levels of EHL-rFIX has shown that different aPTT reagents have different accuracy in measuring different FIX molecules. How will this new knowledge reflect on clinical practice? Clinical decision making in haemophilia B requires some caution and expertise. First, comparisons between different FIX molecules must be assessed taking into consideration the comparability of the populations studied and the PK models used. Second, individual PK estimates must rely on multi-compartmental models, and would benefit from adopting a population PK approach. Optimal sampling times need to be adapted to the prolonged half-life of the new EHL FIX products. Finally, costs considerations may apply, which is beyond the scope of this manuscript but might be deeply connected with the PK considerations discussed in this communication.

  10. Clinical decision making in response to performance validity test failure in a psychiatric setting.

    PubMed

    Marcopulos, Bernice A; Caillouet, Beth A; Bailey, Christopher M; Tussey, Chriscelyn; Kent, Julie-Ann; Frederick, Richard

    2014-01-01

    This study examined the clinical utility of a performance validity test (PVT) for screening consecutive referrals (N = 436) to a neuropsychology service at a state psychiatric hospital treating both civilly committed and forensic patients. We created a contingency table with Test of Memory Malingering (TOMM) pass/fail (355/81) and secondary gain present/absent (181/255) to examine pass rates associated with patient demographic, clinical and forensic status characteristics. Of the 81 failed PVTs, 48 had secondary gain defined as active criminal legal charges; 33 failed PVTs with no secondary gain. These individuals tended to be older, female, Caucasian, and civilly committed compared with the group with secondary gain who failed. From estimations of TOMM False Positive Rate and True Positive Rate we estimated base rates of neurocognitive malingering for our clinical population using the Test Validation Summary (TVS; Frederick & Bowden, 2009 ). Although PVT failure is clearly more common in a group with secondary gain (31%), there were a number of false positives (11%). Clinical ratings of patients without gain who failed suggested cognitive deficits, behavioral issues, and inattention. Low scores on PVTs in the absence of secondary gain provide useful information on test engagement and can inform clinical decisions about testing.

  11. Clinical and histopathological factors affecting failed sentinel node localization in axillary staging for breast cancer.

    PubMed

    Dordea, Matei; Colvin, Hugh; Cox, Phil; Pujol Nicolas, Andrea; Kanakala, Venkat; Iwuchukwu, Obi

    2013-04-01

    Sentinel lymph node biopsy (SLNB) has become the standard of care in axillary staging of clinically node-negative breast cancer patients. To analyze reasons for failure of SLN localization by means of a multivariate analysis of clinical and histopathological factors. We performed a review of 164 consecutive breast cancer patients who underwent SLNB. A superficial injection technique was used. 9/164 patients failed to show nodes. In 7/9 patients no evidence of radioactivity or blue dye was observed. Age and nodal status were the only statistically significant factors (p < 0.05). For every unit increase in age there was a 9% reduced chance of failed SLN localization. Patients with negative nodal status have 90% reduced risk of failed sentinel node localization than patients with macro or extra capsular nodal invasion. The results suggest that altered lymphatic dynamics secondary to tumour burden may play a role in failed sentinel node localization. We showed that in all failed localizations the radiocolloid persisted around the injection site, showing limited local diffusion only. While clinical and histopathological data may provide some clues as to why sentinel node localization fails, we further hypothesize that integrity of peri-areolar lymphatics is important for successful localization. Copyright © 2012 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  12. A Biomechanical Analysis of 2 Constructs for Metacarpal Spiral Fracture Fixation in a Cadaver Model: 2 Large Screws Versus 3 Small Screws.

    PubMed

    Eu-Jin Cheah, Andre; Behn, Anthony W; Comer, Garet; Yao, Jeffrey

    2017-12-01

    Surgeons confronted with a long spiral metacarpal fracture may choose to fix it solely with lagged screws. A biomechanical analysis of a metacarpal spiral fracture model was performed to determine whether 3 1.5-mm screws or 2 2.0-mm screws provided more stability during bending and torsional loading. Second and third metacarpals were harvested from 12 matched pairs of fresh-frozen cadaveric hands and spiral fractures were created. One specimen from each matched pair was fixed with 2 2.0-mm lagged screws whereas the other was fixed with 3 1.5-mm lagged screws. Nine pairs underwent combined cyclic cantilever bending and axial compressive loading followed by loading to failure. Nine additional pairs were subjected to cyclic external rotation while under a constant axial compressive load and were subsequently externally rotated to failure under a constant axial compressive load. Paired t tests were used to compare cyclic creep, stiffness, displacement, rotation, and peak load levels. Average failure torque for all specimens was 7.2 ± 1.7 Nm. In cyclic torsional testing, the group with 2 screws exhibited significantly less rotational creep than the one with 3 screws. A single specimen in the group with 2 screws failed before cyclic bending tests were completed. No other significant differences were found between test groups during torsional or bending tests. Both constructs were biomechanically similar except that the construct with 2 screws displayed significantly less loosening during torsional cyclic loading, although the difference was small and may not be clinically meaningful. Because we found no obvious biomechanical advantage to using 3 1.5-mm lagged screws to fix long spiral metacarpal fractures, the time efficiency and decreased implant costs of using 2-2.0 mm lagged screws may be preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. Three-Year Outcome of Fixed Partial Rehabilitations Supported by Implants Inserted with Flap or Flapless Surgical Techniques.

    PubMed

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando

    2016-07-01

    The aim of this prospective clinical study was to evaluate the 3-year outcome of fixed partial prostheses supported by implants with immediate provisionalization without occlusal contacts inserted in predominantly soft bone with flap and flapless protocols. Forty-one patients partially rehabilitated with 72 NobelSpeedy implants (51 maxillary; 21 mandibular) were consecutively included and treated with a flapless surgical protocol (n = 20 patients; 32 implants) and flapped surgical protocol (n = 21 patients; 40 implants). Primary outcome measure was implant survival; secondary outcome measures were marginal bone resorption (comparing the bone levels at 1 and 3 years with baseline) and the incidence of biological, mechanical, and esthetic complications. Survival was computed through life tables; descriptive statistics were applied to the remaining variables of interest. Eight patients with eight implants dropped out of the study. One implant failed in one patient (flapless group) giving an overall cumulative survival rate (CSR) of 98.6%. No failures were noted with the flapped protocol (CSR 100%), while for the implants placed with the flapless surgical technique, a 96.9% CSR was registered. The overall average marginal bone resorption at 3 years was 1.37 mm (SD = 0.94 mm), with 1.14 mm (SD = 0.49 mm) and 1.60 mm (SD = 1.22 mm) for the flap and flapless groups, respectively. Mechanical complications occurred in nine patients (n = 5 patients in the flapless group; n = 4 patients in the flap group). Implant infection was registered in three implants and three patients (flapless group), who exhibited inadequate oral hygiene levels. Partial edentulism rehabilitation through immediate provisionalization fixed prosthesis supported by dental implants inserted through flap or flapless surgical techniques in areas of predominantly soft bone was viable at 3 years of follow-up. The limitations and risks of the "free-hand" method in flapless surgery should be considered when planning implant-supported fixed prosthetic reconstructions. © 2015 by the American College of Prosthodontists.

  14. Fixed orthodontic appliances in the management of severe dental trauma in mixed dentition: a case report.

    PubMed

    Ebrahim, Fouad-Hassan; Kulkarni, Gajanan

    2013-01-01

    We describe a case of complex trauma to the early mixed dentition in which tooth avulsion, intrusion, extrusion and lateral luxation were managed effectively using a fixed, non-rigid orthodontic splint after treatment with a traditional wire-composite splint had failed. The use of orthodontic brackets and flexible wires provided several advantages, such as the ability to splint severely malpositioned teeth; easy assessment without removing the splint; slow, gentle repositioning of traumatized teeth; and gradual reestablishment of the arch form allowing for ease of future prosthodontic rehabilitation. Therefore, orthodontic appliances should be considered as a viable option for managing complex dental trauma.

  15. Predicting failing performance on a standardized patient clinical performance examination: the importance of communication and professionalism skills deficits.

    PubMed

    Chang, Anna; Boscardin, Christy; Chou, Calvin L; Loeser, Helen; Hauer, Karen E

    2009-10-01

    The purpose is to determine which assessment measures identify medical students at risk of failing a clinical performance examination (CPX). Retrospective case-control, multiyear design, contingency table analysis, n = 149. We identified two predictors of CPX failure in patient-physician interaction skills: low clerkship ratings (odds ratio 1.79, P = .008) and student progress review for communication or professionalism concerns (odds ratio 2.64, P = .002). No assessments predicted CPX failure in clinical skills. Performance concerns in communication and professionalism identify students at risk of failing the patient-physician interaction portion of a CPX. This correlation suggests that both faculty and standardized patients can detect noncognitive traits predictive of failing performance. Early identification of these students may allow for development of a structured supplemental curriculum with increased opportunities for practice and feedback. The lack of predictors in the clinical skills portion suggests limited faculty observation or feedback.

  16. Experiment of comparing coldformed steel shear connection using 2 self drilling screw and sikadur 31cf normal adhesive

    NASA Astrophysics Data System (ADS)

    Sumaidi; Suprobo, P.; Wahyuni, E. dan

    2018-01-01

    Screw connection is prefered used by apllicator because of it’s simple. Type of screw usually used is Self Drilling Screw (SDS). This type of screw will become fix as it’s screwed by the applicator until its head . almost all applicator able to make this connection and do not need some course or sertificate to become an applicator, does not like applicator of High Tension Bolt, HTB. But this type of connection has some disadvantages, for example it’s connection doest not suit to dynamic loading. the experiment results that galvalume material has Yeilding Force, fy = 580 Mpa and Ultimate Force, fu = 590 Mpa. Connection of 2 SDS screw vertically configured fail on about tension loading 6000 N less than horizontally configured that fail on about 7500 N. Displacement of 2 SDS screw vertically configure on about 0.6 mm less than horizontally one that fail on displacement 0.85 mm. For adhesive of Sikadur CF 31 connection fail on loading about 6000 N tension loading but its displacement is less than 0.5 mm when it fail, for 2 type of connection configured.

  17. Cheating: Making It a Teachable Moment

    ERIC Educational Resources Information Center

    Rosile, Grace Ann

    2007-01-01

    The author's PhD training and 25 years of teaching experience did not prepare her for dealing with widespread cheating. Is it better to confront cheaters personally, or just fix the evaluation system and move on? How can the process of failing cheaters be handled in a way that is fair to all? Finally, can a potentially disastrous cheating incident…

  18. Where You Come from or Where You Go? Distinguishing between School Quality and the Effectiveness of Teacher Preparation Program Graduates

    ERIC Educational Resources Information Center

    Mihaly, Kata; McCaffrey, Daniel; Sass, Tim R.; Lockwood, J. R.

    2013-01-01

    We consider the challenges and implications of controlling for school contextual bias when modeling teacher preparation program effects. Because teachers are not randomly distributed across schools, failing to account for contextual factors in achievement models could bias preparation program estimates. Including school fixed effects controls for…

  19. Adolescent Work and Alcohol Use Revisited: Variations by Family Structure

    ERIC Educational Resources Information Center

    Rocheleau, Gregory C.; Swisher, Raymond R.

    2012-01-01

    Previous research finds adolescent work hours to be associated with increased alcohol use. Most studies, however, fail to account for possible selection effects that lead youth to both work and substance use. Using data from the first two waves of the National Longitudinal Study of Adolescent Health (N = 12,620), a fixed effects regression method…

  20. Motor cortex stimulation does not improve dystonia secondary to a focal basal ganglia lesion.

    PubMed

    Rieu, Isabelle; Aya Kombo, Magaly; Thobois, Stéphane; Derost, Philippe; Pollak, Pierre; Xie, Jing; Pereira, Bruno; Vidailhet, Marie; Burbaud, Pierre; Lefaucheur, Jean Pascal; Lemaire, Jean Jacques; Mertens, Patrick; Chabardes, Stephan; Broussolle, Emmanuel; Durif, Franck

    2014-01-14

    To assess the efficacy of epidural motor cortex stimulation (MCS) on dystonia, spasticity, pain, and quality of life in patients with dystonia secondary to a focal basal ganglia (BG) lesion. In this double-blind, crossover, multicenter study, 5 patients with dystonia secondary to a focal BG lesion were included. Two quadripolar leads were implanted epidurally over the primary motor (M1) and premotor cortices, contralateral to the most dystonic side. The leads were placed parallel to the central sulcus. Only the posterior lead over M1 was activated in this study. The most lateral or medial contact of the lead (depending on whether the dystonia predominated in the upper or lower limb) was selected as the anode, and the other 3 as cathodes. One month postoperatively, patients were randomly assigned to on- or off-stimulation for 3 months each, with a 1-month washout between the 2 conditions. Voltage, frequency, and pulse width were fixed at 3.8 V, 40 Hz, and 60 μs, respectively. Evaluations of dystonia (Burke-Fahn-Marsden Scale), spasticity (Ashworth score), pain intensity (visual analog scale), and quality of life (36-Item Short Form Health Survey) were performed before surgery and after each period of stimulation. Burke-Fahn-Marsden Scale, Ashworth score, pain intensity, and quality of life were not statistically significantly modified by MCS. Bipolar epidural MCS failed to improve any clinical feature in dystonia secondary to a focal BG lesion. This study provides Class I evidence that bipolar epidural MCS with the anode placed over the motor representation of the most affected limb failed to improve any clinical feature in dystonia secondary to a focal BG lesion.

  1. The use of cancellous block allograft for sinus floor augmentation with simultaneous implant placement in the posterior atrophic maxilla.

    PubMed

    Chaushu, Gavriel; Mardinger, Ofer; Calderon, Shlomo; Moses, Ofer; Nissan, Joseph

    2009-03-01

    The simultaneous placement of dental implants during sinus augmentation is advocated in cases in which >or=4 to 5 mm of alveolar bone exists coronally to the sinus floor. The aim of the present study was to assess the survival rate of dental implants placed during sinus augmentation and stabilized by the use of cancellous freeze-dried block allograft. Residual alveolar ridge height

  2. Long-term effectiveness of initiating non-nucleoside reverse transcriptase inhibitor- versus ritonavir-boosted protease inhibitor-based antiretroviral therapy: implications for first-line therapy choice in resource-limited settings

    PubMed Central

    Lima, Viviane D; Hull, Mark; McVea, David; Chau, William; Harrigan, P Richard; Montaner, Julio SG

    2016-01-01

    Introduction In many resource-limited settings, combination antiretroviral therapy (cART) failure is diagnosed clinically or immunologically. As such, there is a high likelihood that patients may stay on a virologically failing regimen for a substantial period of time. Here, we compared the long-term impact of initiating non-nucleoside reverse transcriptase inhibitor (NNRTI)- versus boosted protease inhibitor (bPI)-based cART in British Columbia (BC), Canada. Methods We followed prospectively 3925 ART-naïve patients who started NNRTIs (N=1963, 50%) or bPIs (N=1962; 50%) from 1 January 2000 until 30 June 2013 in BC. At six months, we assessed whether patients virologically failed therapy (a plasma viral load (pVL) >50 copies/mL), and we stratified them based on the pVL at the time of failure ≤500 versus >500 copies/mL. We then followed these patients for another six months and calculated their probability of achieving subsequent viral suppression (pVL <50 copies/mL twice consecutively) and of developing drug resistance. These probabilities were adjusted for fixed and time-varying factors, including cART adherence. Results At six months, virologic failure rates were 9.5 and 14.3 cases per 100 person-months for NNRTI and bPI initiators, respectively. NNRTI initiators who failed with a pVL ≤500 copies/mL had a 16% higher probability of achieving subsequent suppression at 12 months than bPI initiators (0.81 (25th–75th percentile 0.75–0.83) vs. 0.72 (0.61–0.75)). However, if failing NNRTI initiators had a pVL >500 copies/mL, they had a 20% lower probability of suppressing at 12 months than pVL-matched bPI initiators (0.37 (0.29–0.45) vs. 0.46 (0.38–0.54)). In terms of evolving HIV drug resistance, those who failed on NNRTI performed worse than bPI in all scenarios, especially if they failed with a viral load >500 copies/mL. Conclusions Our results show that patients who virologically failed at six months on NNRTI and continued on the same regimen had a lower probability of subsequently achieving viral suppression and a higher chance of evolving HIV drug resistance. These results suggest that improving access to regular virologic monitoring is critically important, especially if NNRTI-based cART is to remain a preferred choice for first-line therapy in resource-limited settings. PMID:27499064

  3. Multidisciplinary approach to restoring anterior maxillary partial edentulous area using an IPS Empress 2 fixed partial denture: a clinical report.

    PubMed

    Dundar, Mine; Gungor, M Ali; Cal, Ebru

    2003-04-01

    Esthetics is a major concern during restoration of anterior partial edentulous areas. All-ceramic fixed partial dentures may provide better esthetics and biocompatibility in the restoration of anterior teeth. This clinic report describes a multidisciplinary approach and treatment procedures with an IPS Empress 2 fixed partial denture to restore missing anterior teeth.

  4. Veneered zirconia inlay-retained fixed dental prostheses: 10-Year results from a prospective clinical study.

    PubMed

    Rathmann, Friederike; Bömicke, Wolfgang; Rammelsberg, Peter; Ohlmann, Brigitte

    2017-09-01

    The purpose of this study was to evaluate the 10-year clinical performance of zirconia-based inlay-retained fixed dental prostheses (IRFDP). For replacement of a molar in 27 patients, 30 IRFDP were luted by use of different cements, Panavia F (Kuraray Europe GmbH) or Multilink Automix (Ivoclar Vivadent GmbH), with use of inlay/inlay, inlay/full-crown, or inlay/partial-crown retainers for anchorage. Frameworks were milled from yttria-stabilized zirconia (IPS e.maxZirCAD; Ivoclar Vivadent GmbH) and fully veneered with pressable ceramic (IPS e.max ZirPress; Ivoclar Vivadent GmbH). Before luting, the IRFDP were silica-coated (Rocatec; 3M Espe) and silanized (Monobond S; Ivoclar Vivadent GmbH). Complications (for example, chipping or delamination of the veneering ceramic, debonding, secondary caries, endodontic treatment, and abutment tooth fracture) and failure were reported, by use of standardized report forms, 2 weeks, 6 months, and 1, 2, and 10 years after cementation. Statistical analysis included Kaplan-Meier survival and success (complication-free survival) and Cox regression analysis (α=0.05 for all). During the 10-year observation period, the complications most often observed were chipping of the veneer and debonding. Twenty-five restorations failed and one participant dropped out. Cumulative 10-year survival and success were 12.1% and 0%, respectively. The design of the retainer, use of a dental dam, choice of cement, and location in the dental arch had no statistically significant effect on the occurrence of complications. Use of fully veneered zirconia-based IRFDP with this technique cannot be recommended. A large incidence of complications and poor survival were observed for fully veneered zirconia-based IRFDP, revealing an urgent need for further design improvements for this type of restoration. This, again, emphasizes the need for testing of new restoration designs in clinical trials before implementation in general dental practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Single-blind randomized clinical trial to evaluate clinical and radiological outcomes after one year of immediate versus delayed implant placement supporting full-arch prostheses

    PubMed Central

    Pellicer-Chover, Hilario; Peñarrocha-Oltra, David; Bagán, Leticia; Fichy-Fernandez, Antonio J.; Canullo, Luigi

    2014-01-01

    Purpose: To evaluate and compare peri-implant health, marginal bone loss and success of immediate and delayed implant placement for rehabilitation with full-arch fixed prostheses. Material and Methods: The present study was a prospective, randomized, single-blind, clinical preliminary trial. Patients were randomized into two treatment groups. In Group A implants were placed immediately post-extraction and in Group B six months after extraction. The following control time-points were established: one week, six months and twelve months after loading. Measurements were taken of peri-implant crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified gingival index and presence of mucositis. Implant success rates were evaluated for the two groups. The study sample included fifteen patients (nine women and six men) with a mean average age of 63.7 years. One hundred and forty-four implants were placed: 76 placed in healed sites and 68 placed immediately. Results: At the moment of prosthetic loading, keratinized mucosa width and probing depth were higher in immediate implants than delayed implants, with statistically significant differences. However, after six and twelve months, differences between groups had disappeared. Bone loss was 0.54 ± 0.39 mm for immediate implants and 0.66 ± 0.25 mm for delayed implants (p=0.201). No implants failed in either group. Conclusions: The present study with a short follow-up and a small sample yielded no statistically significant differences in implant success and peri-implant marginal bone loss between immediate and delayed implants with fixed full-arch prostheses. Peri-implant health showed no statistically significant differences for any of the studied parameters (crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified gingival index and presence of mucositis) at the twelve-month follow-up. Key words:Immediate implants, delayed implants, peri-implant health, success rate. PMID:24316712

  6. Banding versus bonding of first permanent molars: a multi-centre randomized controlled trial.

    PubMed

    Nazir, Mariyah; Walsh, Tanya; Mandall, Nicky A; Matthew, Susie; Fox, Dee

    2011-06-01

    To assess the effectiveness of banding versus bonding of first permanent molars during fixed appliance treatment; in terms of attachment failure, patient discomfort and post-treatment enamel demineralization. Multi-centre randomized clinical trial. One District General Hospital Orthodontic Department and two Specialist Orthodontic Practices. Orthodontic patients aged between 10 and 18 years old, randomly allocated to either receive molar bands (n=40) or molar bonds (n=40). Bands were cemented with a conventional glass ionomer cement and tubes were bonded with light-cured composite to all four first permanent molar teeth for each subject. Attachments were reviewed at each recall appointment to assess loosening or loss. The clinical end point of the trial was the day of appliance debond. Enamel demineralization at debond was assessed using the modified International Caries Assessment and Detection System (ICDAS). The first time failure rate for molar bonds was 18·4% and 2·6% for molar bands (P=0·0002). Survival analysis demonstrated molar bonds were more likely to fail compared with molar bands. First permanent molars with bonded tubes experienced more demineralization than those with cemented bands (P=0·027). There was no statistically significant difference in discomfort experienced by patients after banding or bonding first permanent molars (P>0·05). This study shows that as part of fixed appliance therapy, American Orthodontics photoetched first permanent molar bands cemented with 3M ESPE Ketac-Cem perform better than American Orthodontics low profile photo-etched and mesh-based first permanent molar tubes bonded with 3M Unitek Transbond XT in terms of failure behaviour and molar enamel demineralization.

  7. Publication Bias in Meta-Analysis: Confidence Intervals for Rosenthal's Fail-Safe Number.

    PubMed

    Fragkos, Konstantinos C; Tsagris, Michail; Frangos, Christos C

    2014-01-01

    The purpose of the present paper is to assess the efficacy of confidence intervals for Rosenthal's fail-safe number. Although Rosenthal's estimator is highly used by researchers, its statistical properties are largely unexplored. First of all, we developed statistical theory which allowed us to produce confidence intervals for Rosenthal's fail-safe number. This was produced by discerning whether the number of studies analysed in a meta-analysis is fixed or random. Each case produces different variance estimators. For a given number of studies and a given distribution, we provided five variance estimators. Confidence intervals are examined with a normal approximation and a nonparametric bootstrap. The accuracy of the different confidence interval estimates was then tested by methods of simulation under different distributional assumptions. The half normal distribution variance estimator has the best probability coverage. Finally, we provide a table of lower confidence intervals for Rosenthal's estimator.

  8. Publication Bias in Meta-Analysis: Confidence Intervals for Rosenthal's Fail-Safe Number

    PubMed Central

    Fragkos, Konstantinos C.; Tsagris, Michail; Frangos, Christos C.

    2014-01-01

    The purpose of the present paper is to assess the efficacy of confidence intervals for Rosenthal's fail-safe number. Although Rosenthal's estimator is highly used by researchers, its statistical properties are largely unexplored. First of all, we developed statistical theory which allowed us to produce confidence intervals for Rosenthal's fail-safe number. This was produced by discerning whether the number of studies analysed in a meta-analysis is fixed or random. Each case produces different variance estimators. For a given number of studies and a given distribution, we provided five variance estimators. Confidence intervals are examined with a normal approximation and a nonparametric bootstrap. The accuracy of the different confidence interval estimates was then tested by methods of simulation under different distributional assumptions. The half normal distribution variance estimator has the best probability coverage. Finally, we provide a table of lower confidence intervals for Rosenthal's estimator. PMID:27437470

  9. [Granulomatous sporotrichosis: report of two unusual cases].

    PubMed

    Ramírez-Soto, Max; Lizárraga-Trujillo, José

    2013-10-01

    Sporotrichosis is a subcutaneous mycosis caused by Sporothrix complex, endemic in Abancay, Peru. Is acquired by traumatic inoculation with plant material. Common clinical presentations are lymphatic cutaneous and fixed cutaneous disease. We report 2 cases of fixed cutaneous sporotrichosis with granulomatous appearance. The first case was a patient of 65 years old with no risk factors and the second case was a 67 year old diabetic patient. Subjects underwent mycological culture with Sabouraud agar, with isolation of Sporothrix schenckii and clinical dignosis of fixed cutaneous sporotrichosis with granulomatous appearance. One patient received oral treatment with saturated solution of potassium iodide (SSKI) with a initial dose of 3 drops tid up to a maximum dose of 40 drops tid. Mycological and clinical cure was achieved after 2 months of treatment. We should consider the unusual clinical presentations of fixed cutaneous sporotrichosis with granulomatous appearance that present morphological and clinical features in diabetic and nondiabetic patients older than 60 years from endemic areas and communicate adequate response to treatment with SSKI in one case.

  10. Anticonvulsant and antipunishment effects of toluene.

    PubMed

    Wood, R W; Coleman, J B; Schuler, R; Cox, C

    1984-08-01

    Toluene can have striking acute behavioral effects and is subject to abuse by inhalation. To determine if its actions resemble those of drugs used in the treatment of anxiety ("anxiolytics"), two sets of experiments were undertaken. Inasmuch as prevention of pentylenetetrazol-induced convulsions is an identifying property of this class of agents, we first demonstrated that pretreatment with injections of toluene delayed the onset of convulsive signs and prevented the tonic extension phase of the convulsant activity in a dose-related manner. Injections of another alkyl benzene, m-xylene, were of comparable potency to toluene. Inhalation of toluene delayed the time to death after pentylenetetrazol injection in a manner related to the duration and concentration of exposure; at lower convulsant doses, inhalation of moderate concentrations (EC50, 1311 ppm) prevented death. Treatment with a benzodiazepine receptor antagonist (Ro 15-1788) failed to reduce the anticonvulsant activity of inhaled toluene. Anxiolytics also attenuate the reduction in response rate produced by punishment with electric shock. Toluene increased rates of responding suppressed by punishment when responding was maintained under a multiple fixed-interval fixed-interval punishment schedule of reinforcement. Distinct antipunishment effects were observed after 2 hr of exposure to 1780 and 3000 ppm of toluene; the rate-increasing effects of toluene were related to concentration and to time after the termination of exposure. Thus, toluene and m-xylene resemble in several respects clinically useful drugs such as the benzodiazepines.

  11. Retrospective cohort study of the clinical performance of 1-stage dental implants.

    PubMed

    Carr, Alan B; Choi, Yong-Geun; Eckert, Steven E; Desjardins, Ronald P

    2003-01-01

    To evaluate long-term clinical performance of 1-stage dental implant prostheses at a single clinic, emphasizing clinical and demographic characteristics that affect implant survival. Dental records of all 308 patients (674 implants) treated with 1-stage implants at Mayo Clinic from October 1993 through May 2000 were reviewed from implant placement to last visit. Exposure and outcome variables affecting performance were collected separately to control bias in the data collection process. Additional confounding factors (age and sex) were adjusted with the stratified Cox proportional hazards model. Implant survival was determined by means of a Kaplan-Meier survival estimate. The log-rank test was used to determine the role of clinical and demographic variables in implant survival. The relative risk associated with the possible effect of clinical and demographic variables on implant survival was estimated with the Cox proportional hazards model. The implant survival rate (n = 654 implants) was 97% (mean +/- SD follow-up, 21.0 +/- 18.8 months; range, 1 to 78 months). Performance bias was limited because nearly all patients were treated by 1 prosthodontist. Two implants failed after loading (6 and 9 months). The incidence of complications was less than 4%. Among the implant failures, use of heterogeneous bone graft was associated with 4.8 times more failures than was use of autogenous bone graft (P = .04). After augmentation, delaying implant placement for 5 to 6 months resulted in 8.6 times more failures than the rate after earlier placement (P < .001). Retrospective review of the clinical performance of a 1-stage dental implant system yielded a 97% survival rate, with no failures noted after 13 months. Prosthetic complications were low, especially for fixed implant prostheses. Clinical performance of 1-stage dental implant prostheses between 1993 and 2000 demonstrated a high level of predictability.

  12. Generic simulation of multi-element ladar scanner kinematics in USU LadarSIM

    NASA Astrophysics Data System (ADS)

    Omer, David; Call, Benjamin; Pack, Robert; Fullmer, Rees

    2006-05-01

    This paper presents a generic simulation model for a ladar scanner with up to three scan elements, each having a steering, stabilization and/or pattern-scanning role. Of interest is the development of algorithms that automatically generate commands to the scan elements given beam-steering objectives out of the ladar aperture, and the base motion of the sensor platform. First, a straight-forward single-element body-fixed beam-steering methodology is presented. Then a unique multi-element redirective and reflective space-fixed beam-steering methodology is explained. It is shown that standard direction cosine matrix decomposition methods fail when using two orthogonal, space-fixed rotations, thus demanding the development of a new algorithm for beam steering. Finally, a related steering control methodology is presented that uses two separate optical elements mathematically combined to determine the necessary scan element commands. Limits, restrictions, and results on this methodology are presented.

  13. Glecaprevir + pibrentasvir for treatment of hepatitis C.

    PubMed

    Carrion, Andres F; Martin, Paul

    2018-03-01

    Glecaprevir/pibrentasvir is a fixed-dose combination regimen of a new generation NS3/4A inhibitor and an NS5A inhibitor with potent antiviral activity against all hepatitis C virus (HCV) genotypes. This regimen offers a shorter course of therapy (8 weeks) for selected patients regardless of genotype and has demonstrated high virological efficacy for retreatment of individuals who previously failed an NS5A containing regimen. Glecaprevir and pibrentasvir are minimally excreted by the kidneys; thus this regimen can safely be used in individuals with severe chronic kidney disease (CKD), including those undergoing hemodialysis. Areas covered: This review covers the mechanism of action, pharmacokinetics, clinical applications, efficacy, and safety profile of glecaprevir/pibrentasvir. It also covers key phase 2 and 3 clinical trials that led to licensure of this regimen. Expert opinion: Glecaprevir/pibrentasvir is the latest antiviral regimen licensed in the United States for treatment of HCV infection. Although several other direct-acting antiviral agents (DAAs) are currently available, glecaprevir/pibrentasvir has some unique characteristics that expand treatment options for HCV infection, including patients with comorbidities such as advanced stage CKD or prior treatment failure to antiviral regimens containing other DAAs.

  14. Controlling cyanobacterial blooms in hypertrophic Lake Taihu, China: will nitrogen reductions cause replacement of non-N2 fixing by N2 fixing taxa?

    PubMed

    Paerl, Hans W; Xu, Hai; Hall, Nathan S; Zhu, Guangwei; Qin, Boqiang; Wu, Yali; Rossignol, Karen L; Dong, Linghan; McCarthy, Mark J; Joyner, Alan R

    2014-01-01

    Excessive anthropogenic nitrogen (N) and phosphorus (P) inputs have caused an alarming increase in harmful cyanobacterial blooms, threatening sustainability of lakes and reservoirs worldwide. Hypertrophic Lake Taihu, China's third largest freshwater lake, typifies this predicament, with toxic blooms of the non-N2 fixing cyanobacteria Microcystis spp. dominating from spring through fall. Previous studies indicate N and P reductions are needed to reduce bloom magnitude and duration. However, N reductions may encourage replacement of non-N2 fixing with N2 fixing cyanobacteria. This potentially counterproductive scenario was evaluated using replicate, large (1000 L), in-lake mesocosms during summer bloom periods. N+P additions led to maximum phytoplankton production. Phosphorus enrichment, which promoted N limitation, resulted in increases in N2 fixing taxa (Anabaena spp.), but it did not lead to significant replacement of non-N2 fixing with N2 fixing cyanobacteria, and N2 fixation rates remained ecologically insignificant. Furthermore, P enrichment failed to increase phytoplankton production relative to controls, indicating that N was the most limiting nutrient throughout this period. We propose that Microcystis spp. and other non-N2 fixing genera can maintain dominance in this shallow, highly turbid, nutrient-enriched lake by outcompeting N2 fixing taxa for existing sources of N and P stored and cycled in the lake. To bring Taihu and other hypertrophic systems below the bloom threshold, both N and P reductions will be needed until the legacy of high N and P loading and sediment nutrient storage in these systems is depleted. At that point, a more exclusive focus on P reductions may be feasible.

  15. Controlling Cyanobacterial Blooms in Hypertrophic Lake Taihu, China: Will Nitrogen Reductions Cause Replacement of Non-N2 Fixing by N2 Fixing Taxa?

    PubMed Central

    Paerl, Hans W.; Xu, Hai; Hall, Nathan S.; Zhu, Guangwei; Qin, Boqiang; Wu, Yali; Rossignol, Karen L.; Dong, Linghan; McCarthy, Mark J.; Joyner, Alan R.

    2014-01-01

    Excessive anthropogenic nitrogen (N) and phosphorus (P) inputs have caused an alarming increase in harmful cyanobacterial blooms, threatening sustainability of lakes and reservoirs worldwide. Hypertrophic Lake Taihu, China’s third largest freshwater lake, typifies this predicament, with toxic blooms of the non-N2 fixing cyanobacteria Microcystis spp. dominating from spring through fall. Previous studies indicate N and P reductions are needed to reduce bloom magnitude and duration. However, N reductions may encourage replacement of non-N2 fixing with N2 fixing cyanobacteria. This potentially counterproductive scenario was evaluated using replicate, large (1000 L), in-lake mesocosms during summer bloom periods. N+P additions led to maximum phytoplankton production. Phosphorus enrichment, which promoted N limitation, resulted in increases in N2 fixing taxa (Anabaena spp.), but it did not lead to significant replacement of non-N2 fixing with N2 fixing cyanobacteria, and N2 fixation rates remained ecologically insignificant. Furthermore, P enrichment failed to increase phytoplankton production relative to controls, indicating that N was the most limiting nutrient throughout this period. We propose that Microcystis spp. and other non-N2 fixing genera can maintain dominance in this shallow, highly turbid, nutrient-enriched lake by outcompeting N2 fixing taxa for existing sources of N and P stored and cycled in the lake. To bring Taihu and other hypertrophic systems below the bloom threshold, both N and P reductions will be needed until the legacy of high N and P loading and sediment nutrient storage in these systems is depleted. At that point, a more exclusive focus on P reductions may be feasible. PMID:25405474

  16. Autonomous Component Health Management with Failed Component Detection, Identification, and Avoidance

    NASA Technical Reports Server (NTRS)

    Davis, Robert N.; Polites, Michael E.; Trevino, Luis C.

    2004-01-01

    This paper details a novel scheme for autonomous component health management (ACHM) with failed actuator detection and failed sensor detection, identification, and avoidance. This new scheme has features that far exceed the performance of systems with triple-redundant sensing and voting, yet requires fewer sensors and could be applied to any system with redundant sensing. Relevant background to the ACHM scheme is provided, and the simulation results for the application of that scheme to a single-axis spacecraft attitude control system with a 3rd order plant and dual-redundant measurement of system states are presented. ACHM fulfills key functions needed by an integrated vehicle health monitoring (IVHM) system. It is: autonomous; adaptive; works in realtime; provides optimal state estimation; identifies failed components; avoids failed components; reconfigures for multiple failures; reconfigures for intermittent failures; works for hard-over, soft, and zero-output failures; and works for both open- and closed-loop systems. The ACHM scheme combines a prefilter that generates preliminary state estimates, detects and identifies failed sensors and actuators, and avoids the use of failed sensors in state estimation with a fixed-gain Kalman filter that generates optimal state estimates and provides model-based state estimates that comprise an integral part of the failure detection logic. The results show that ACHM successfully isolates multiple persistent and intermittent hard-over, soft, and zero-output failures. It is now ready to be tested on a computer model of an actual system.

  17. Assessing the President's Proposals on Higher Education Costs. WebMemo. No. 3480

    ERIC Educational Resources Information Center

    Butler, Stuart M.

    2012-01-01

    President Obama is right to draw attention to the soaring cost of a college education in America. However, his proposed solution will not only fail to fix the problem but is also likely to compound it by blunting the competition that is needed to shake up the world of higher education. President Obama proposes to slow tuition growth by…

  18. Hospital-affiliated practices reduce 'red ink'.

    PubMed

    Bohlmann, R C

    1998-01-01

    Many complain that hospital-group practice affiliations are a failed model and should be abandoned. The author argues for a less rash approach, saying the goal should be to understand the problems precisely, then fix them. Benchmarking is a good place to start. The article outlines the basic definition and ground rules of bench-marking and explains what resources help accomplish the task.

  19. Strategic Supply

    DTIC Science & Technology

    2006-01-01

    leaders as Sears, Limited Brands, DHL, Circuit City, Cingular, Nestle and IKEA (Manugistics, 2006). The Strategic Supply Chain Industry Study Group...inventory turns have increased. Other global customers have also reaped the benefits of the Manugistics software. IKEA , Sweden’s retail icon...turned to Manugistics after a mid-1990s ERP implementation failed to fix their forecasting problems, which gave way to fluctuating inventory levels. IKEA

  20. 76 FR 77287 - Self-Regulatory Organizations; Fixed Income Clearing Corporation; Notice of Filing of Proposed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-12

    ... details submitted by members.\\4\\ Additionally, a new pool netting system will perform a daily net of pool... the net position of Members without regard to the original counterparty relationship. With a trade... month factor on the pool number. \\11\\ The MBSD will retain the discretion to re-net fails or to conduct...

  1. Fail-fixed servovalve with positive fluid feedback

    NASA Technical Reports Server (NTRS)

    Kast, Howard B. (Inventor)

    1984-01-01

    The servovalve includes a primary jet of fluid. A variable control signal is adapted to vary the angular position of the primary jet from its maximum recovery position. A first fluid path is adapted to supply fluid to a servopiston at a variable pressure determined at least in part by the control signal. A second fluid path is adapted to receive a predetermined portion of the primary jet fluid when the control signal reaches a predetermined value. The second fluid path terminates in the vicinity of the primary jet and is adapted to direct a secondary jet of fluid at the primary jet to deflect the primary jet toward the input orifice of the second fluid path. The resultant positive fluid feedback in the second fluid path causes the primary jet to latch in a first angular position relative to the maximum recovery position when the control signal reaches a predetermined value. The servovalve may further include a means to discharge the fluid and a means to block the first fluid path to the servopiston when the control signal falls below a second predetermined value. A method of operating a fail-fixed servovalve is also described.

  2. Fiber-reinforced composite fixed dental prostheses: two clinical reports.

    PubMed

    Zarow, Maciej; Paisley, Carl Stuart; Krupinski, Jerzy; Brunton, Paul Anthony

    2010-06-01

    Various options are available in clinical practice for the replacement of a single missing tooth, ranging from conventional fixed and removable dental prostheses to a single implant-supported crown. There are situations in which a semipermanent fixed dental prosthesis may be desirable, particularly for patients who have completed orthodontic treatment but are too young to embark on implant therapy. Following advances in fiber-reinforcement technology, fiber-reinforced composite resin (FRC) now represents a lower-cost alternative to traditional metal-ceramic for the construction of resin-bonded prostheses. Two case reports illustrate the use of FRC prostheses as fixed semipermanent_restorations.

  3. SUBCLINICAL INFECTION OF DOGS BY CANINE-ADAPTED MEASLES VIRUS EVIDENCED BY THEIR SUBSEQUENT IMMUNITY TO CANINE DISTEMPER VIRUS

    PubMed Central

    Moura, Roberto A.; Warren, Joel

    1961-01-01

    Moura, Roberto A. (Chas. Pfizer and Company, Inc., Terre Haute, Ind.) and Joel Warren. Subclinical infection of dogs by canine-adapted measles virus evidenced by their subsequent immunity to canine distemper virus. J. Bacteriol. 82:702–705. 1961.—Young dogs were inoculated with virulent measles virus which had been adapted to canine kidney or human amnion cell culture. None of the animals showed any clinical symptoms nor could virus be isolated from the blood, although measles-neutralizing and complement-fixing antibodies developed during convalescence. All dogs failed to develop antibody to canine distemper. However, when these and normal control animals were subsequently inoculated intracerebrally with virulent distemper virus, each of the controls succumbed to typical symptoms, whereas all of the measles-immune dogs survived. These results suggest that the cross-protection conferred by measles against canine distemper virus infection involves factors other than humoral antibody. The immunity persists for a considerable length of time. PMID:14476677

  4. Why Do Medial Unicompartmental Knee Arthroplasties Fail Today?

    PubMed

    van der List, Jelle P; Zuiderbaan, Hendrik A; Pearle, Andrew D

    2016-05-01

    Failure rates are higher in medial unicompartmental knee arthroplasty (UKA) than total knee arthroplasty. To improve these failure rates, it is important to understand why medial UKA fail. Because individual studies lack power to show failure modes, a systematic review was performed to assess medial UKA failure modes. Furthermore, we compared cohort studies with registry-based studies, early with midterm and late failures and fixed-bearing with mobile-bearing implants. Databases of PubMed, EMBASE, and Cochrane and annual registries were searched for medial UKA failures. Studies were included when they reported >25 failures or when they reported early (<5 years), midterm (5-10 years), or late failures (>10 years). Thirty-seven cohort studies (4 level II studies and 33 level III studies) and 2 registry-based studies were included. A total of 3967 overall failures, 388 time-dependent failures, and 1305 implant design failures were identified. Aseptic loosening (36%) and osteoarthritis (OA) progression (20%) were the most common failure modes. Aseptic loosening (26%) was most common early failure mode, whereas OA progression was more commonly seen in midterm and late failures (38% and 40%, respectively). Polyethylene wear (12%) and instability (12%) were more common in fixed-bearing implants, whereas pain (14%) and bearing dislocation (11%) were more common in mobile-bearing implants. This level III systematic review identified aseptic loosening and OA progression as the major failure modes. Aseptic loosening was the main failure mode in early years and mobile-bearing implants, whereas OA progression caused most failures in late years and fixed-bearing implants. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Early outcome of TKA with a medial pivot fixed-bearing prosthesis is worse than with a PFC mobile-bearing prosthesis.

    PubMed

    Kim, Young-Hoo; Yoon, Sung-Hwan; Kim, Jun-Shik

    2009-02-01

    Although the design features of the Medial Pivot fixed-bearing prosthesis reportedly improve kinematics compared with TKAs using fixed-bearings, clinical improvements have not been reported. We asked whether the clinical and radiographic outcomes, ranges of motion of the knee, patient satisfaction, and complication rates would be better in knees with a Medial Pivot fixed-bearing prosthesis than in those with a PFC Sigma mobile-bearing prosthesis. We compared the results of 92 patients who had a Medial Pivot fixed-bearing prosthesis implanted in one knee and a PFC Sigma mobile-bearing prosthesis implanted in the other. There were 85 women and seven men with a mean age of 69.5 years (range, 55-81 years). The minimum followup was 2 years (mean, 2.6 years; range, 2-3 years). The patients were assessed clinically and radiographically using the rating systems of the Hospital for Special Surgery and the Knee Society at 3 months, 1 year, and annually thereafter. Contrary to expectations, we found worse early clinical outcomes, smaller ranges of knee motion, less patient satisfaction, and a higher complication rate for the Medial Pivot fixed-bearing prosthesis than for the PFC Sigma mobile-bearing prosthesis. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  6. Clinical Success of Fiber-reinforced Composite Resin as a Space Maintainer.

    PubMed

    Kirzioğlu, Zuhal; Çiftçi, Z Zahit; Yetiş, Ceylan Ç

    2017-03-01

    The early loss of deciduous molars is a frequently encountered problem in dentistry. Various space maintainer designs were developed to prevent the loss of the space. The aim of this study was to evaluate long-term clinical performance and survival rates of fiber-reinforced composite resin (FRCR) as a space maintainer clinically. This study was designed on 44 children who had early missed deciduous molars. Space maintainers were prepared on plaster models of patients and fixed directly to the adjacent teeth. Survival rate and whether it causes any damage to adjacent teeth were examined clinically and radio-graphically for 24 months or until failure. Kaplan-Meier survival analysis was used for the statistical analyses. Overall, 16.2% of space maintainers were dislodged and accepted to be failed at the end of 12 months. At the 24-month control, 52.2% success was stated with the FRCR space maintainer and because of permanent tooth eruption, 31.8% of space maintainer were taken out. The mean duration of space maintainers was measured to be 14.8 ± 3.48 months. There was no statistical significance between survival time and gender, tooth number, localization, and measured space (p > 0.05). After all 24 months follow-up, as well as esthetic properties of FRCR space maintainer, their applicability in a single seance and strength against the forces are determined as the advantages of the technique. The FRCR space maintainers can be thought of as alternatives to metal space maintainers.

  7. Can emergency medicine research benefit from adaptive design clinical trials?

    PubMed

    Flight, Laura; Julious, Steven A; Goodacre, Steve

    2017-04-01

    Adaptive design clinical trials use preplanned interim analyses to determine whether studies should be stopped or modified before recruitment is complete. Emergency medicine trials are well suited to these designs as many have a short time to primary outcome relative to the length of recruitment. We hypothesised that the majority of published emergency medicine trials have the potential to use a simple adaptive trial design. We reviewed clinical trials published in three emergency medicine journals between January 2003 and December 2013. We determined the proportion that used an adaptive design as well as the proportion that could have used a simple adaptive design based on the time to primary outcome and length of recruitment. Only 19 of 188 trials included in the review were considered to have used an adaptive trial design. A total of 154/165 trials that were fixed in design had the potential to use an adaptive design. Currently, there seems to be limited uptake in the use of adaptive trial designs in emergency medicine despite their potential benefits to save time and resources. Failing to take advantage of adaptive designs could be costly to patients and research. It is recommended that where practical and logistical considerations allow, adaptive designs should be used for all emergency medicine clinical trials. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. [Fractographic analysis of clinically failed anterior all ceramic crowns].

    PubMed

    DU, Qian; Zhou, Min-bo; Zhang, Xin-ping; Zhao, Ke

    2012-04-01

    To identify the site of crack initiation and propagation path of clinically failed all ceramic crowns by fractographic analysis. Three clinically failed anterior IPS Empress II crowns and two anterior In-Ceram alumina crowns were retrieved. Fracture surfaces were examined using both optical stereo and scanning electron microscopy. Fractographic theory and fracture mechanics principles were applied to disclose the damage characteristics and fracture mode. All the crowns failed by cohesive failure within the veneer on the labial surface. Critical crack originated at the incisal contact area and propagated gingivally. Porosity was found within the veneer because of slurry preparation and the sintering of veneer powder. Cohesive failure within the veneer is the main failure mode of all ceramic crown. Veneer becomes vulnerable when flaws are present. To reduce the chances of chipping, multi-point occlusal contacts are recommended, and layering and sintering technique of veneering layer should also be improved.

  9. The transfer of theoretical knowledge to clinical practice by nursing students and the difficulties they experience: A qualitative study.

    PubMed

    Günay, Ulviye; Kılınç, Gülsen

    2018-06-01

    Nursing education contains both theoretical and practical training processes. Clinical training is the basis of nursing education. The quality of clinical training is closely related to the quality of the clinical learning environment. This study aimed to determine the transfer of theoretical knowledge into clinical practice by nursing students and the difficulties they experience during this process. A qualitative research design was used in the study. The study was conducted in 2015 with 30 nursing students in a university located in the east of Turkey, constituting three focus groups. The questions directed to the students during the focus group interviews were as follows: What do you think about your clinical training? How do you evaluate yourself in the process of putting your theoretical knowledge into clinical practice? What kind of difficulties are you experiencing in clinical practices? The data were interpreted using the method of content analysis. Most of the students reported that theoretical information they received was excessive, their ability to put most of this information into practice was weak, and they lacked courage to touch patients for fear of implementing procedures incorrectly. As a result of the analysis of the data, five main themes were determined: clinical training, guidance and communication, hospital environment and expectations. The results of this study showed that nursing students found their clinical knowledge and skills insufficient and usually failed to transfer their theoretical knowledge into clinical practices. The study observed that nursing students experienced various issues in clinical practices. In order to fix these issues and achieve an effective clinical training environment, collaboration should be achieved among nursing instructors, nurses, nursing school and hospital managements. Additionally, the number of nursing educators should be increased and training programs should be provided regarding effective clinical training methods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Tn5-Mob transposon mediated transfer of salt tolerance and symbiotic characteristics between Rhizobia genera.

    PubMed

    Yang, S; Wu, Z; Gao, W; Li, J

    1993-01-01

    Rhizobium meliloti 042B is a fast-growing, salt-tolerant and high efficiency nitrogen-fixing symbiont with alfalfa. Bradyrhizobium japonicum USDA110 grows slowly, and cannot grow in YMA medium containing 0.1M NaCl, but nodulates and fixed nitrogen efficiently with soybean. Eighty-six transconjugants, called SR, were obtained by inserting Tn5-Mob randomly into genomes of 042B using pSUP5011 and helper plasmid RP4. Selecting 4 SR strains randomly and introducing DNA fragment of SR into USDA110 with helper plasmid R68.45 by triparental mating, 106 transconjugants, called BSR, were constructed. Most of BSR strains had the fast-growing phenotype and could tolerate 0.3-0.5M NaCl generally. Some of them produced melanine. When soybean and alfalfa were inoculated with these transconjugants BSR, 47 out of 90 BSR were found to nodulate in both of these plants, but no nitrogenase activity was observed with alfalfa; 26 strains could only nodulate and fix nitrogen in soybean; 13 strains could nodulate in alfalfa but did not fix nitrogen; 4 strains failed to nodulate in either soybean or alfalfa. Among them, 4 transconjugants which tolerated and fixed nitrogen efficiently in soybean were constructed.

  11. Job stress and mental health of permanent and fixed-term workers measured by effort-reward imbalance model, depressive complaints, and clinic utilization.

    PubMed

    Inoue, Mariko; Tsurugano, Shinobu; Yano, Eiji

    2011-01-01

    The number of workers with precarious employment has increased globally; however, few studies have used validated measures to investigate the relationship of job status to stress and mental health. Thus, we conducted a study to compare differential job stress experienced by permanent and fixed-term workers using an effort-reward imbalance (ERI) model questionnaire, and by evaluating depressive complaints and clinic utilization. Subjects were permanent or fixed-term male workers at a Japanese research institute (n=756). Baseline data on job stress and depressive complaints were collected in 2007. We followed up with the same population over a 1-year period to assess their utilization of the company clinic for mental health concerns. The ERI ratio was higher among permanent workers than among fixed-term workers. More permanent workers presented with more than two depressive complaints, which is the standard used for the diagnosis of depression. ERI scores indicated that the effort component of permanent work was associated with distress, whereas distress in fixed-term work was related to job promotion and job insecurity. Moreover, over the one-year follow-up period, fixed-term workers visited the on-site clinic for mental concerns 4.04 times more often than permanent workers even after adjusting for age, lifestyle, ERI, and depressive complaints. These contrasting findings reflect the differential workloads and working conditions encountered by permanent and fixed-term workers. The occupational setting where employment status was intermingled, may have contributed to the high numbers of mental health-related issues experienced by workers with different employment status.

  12. Benchmarks and Reliable DFT Results for Spin Gaps of Small Ligand Fe(II) Complexes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Suhwan; Kim, Min-Cheol; Sim, Eunji

    2017-05-01

    All-electron fixed-node diffusion Monte Carlo provides benchmark spin gaps for four Fe(II) octahedral complexes. Standard quantum chemical methods (semilocal DFT and CCSD(T)) fail badly for the energy difference between their high- and low-spin states. Density-corrected DFT is both significantly more accurate and reliable and yields a consistent prediction for the Fe-Porphyrin complex

  13. Resistance to Viral Challenge in the Days Immediately Following Vaccination.

    DTIC Science & Technology

    Powassan or yellow fever, by the intraperitoneal route into guinea pigs failed to induce visible signs of illness; however, with Japanese encephalitis... Powassan , and Banzi viruses, high titered complement-fixing antibodies developed. Since no disease and death could be used as a criterion of successful...infection of guinea pigs inoculated with Japanese encephalitis virus, or of hamsters inoculated with Powassan , an alternative method of determining

  14. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.

    PubMed

    Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M

    2015-12-01

    This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.

  15. AAV liver expression of FIX-Padua prevents and eradicates FIX inhibitor without increasing thrombogenicity in hemophilia B dogs and mice.

    PubMed

    Crudele, Julie M; Finn, Jonathan D; Siner, Joshua I; Martin, Nicholas B; Niemeyer, Glenn P; Zhou, Shangzhen; Mingozzi, Federico; Lothrop, Clinton D; Arruda, Valder R

    2015-03-05

    Emerging successful clinical data on gene therapy using adeno-associated viral (AAV) vector for hemophilia B (HB) showed that the risk of cellular immune response to vector capsid is clearly dose dependent. To decrease the vector dose, we explored AAV-8 (1-3 × 10(12) vg/kg) encoding a hyperfunctional factor IX (FIX-Padua, arginine 338 to leucine) in FIX inhibitor-prone HB dogs. Two naïve HB dogs showed sustained expression of FIX-Padua with an 8- to 12-fold increased specific activity reaching 25% to 40% activity without antibody formation to FIX. A third dog with preexisting FIX inhibitors exhibited a transient anamnestic response (5 Bethesda units) at 2 weeks after vector delivery following by spontaneous eradication of the antibody to FIX by day 70. In this dog, sustained FIX expression reached ∼200% and 30% of activity and antigen levels, respectively. Immune tolerance was confirmed in all dogs after challenges with plasma-derived FIX concentrate. Shortening of the clotting times and lack of bleeding episodes support the phenotypic correction of the severe phenotype, with no clinical or laboratory evidence of risk of thrombosis. Provocative studies in mice showed that FIX-Padua exhibits similar immunogenicity and thrombogenicity compared with FIX wild type. Collectively, these data support the potential translation of gene-based strategies using FIX-Padua for HB. © 2015 by The American Society of Hematology.

  16. [Fool's gold standards in language screening. Sensitivity and specificity of the Hessian child language screening test (Kindersprachscreening, KiSS)].

    PubMed

    Neumann, K; Holler-Zittlau, I; van Minnen, S; Sick, U; Zaretsky, Y; Euler, H A

    2011-01-01

    The German Kindersprachscreening (KiSS) is a universal speech and language screening test for large-scale identification of Hessian kindergarten children requiring special educational language training or clinical speech/language therapy. To calculate the procedural screening validity, 257 children (aged 4.0 to 4.5 years) were tested using KiSS and four language tests (Reynell Development Language Scales III, Patholinguistische Diagnostik, PLAKSS, AWST-R). The majority or consensus judgements of three speech-language professionals, based on the language test results, served as a reference criterion. The base (fail) rates of the professionals were either self-determined or preset based on known prevalence rates. Screening validity was higher for preset than for self-determined base rates due to higher inter-judge agreement. The confusion matrices of the overall index classification of the KiSS (speech-language abnormalities with educational or clinical needs) with the fixed base rate expert judgement about language impairment, including fluency or voice disorders, yielded a sensitivity of 88% and a specificity of 78%, for just language impairment 84% and 75%, respectively. Specificities for disorders requiring clinical diagnostics in the KiSS (language impairment alone or combined with fluency/voice disorders) related to the test-based consensus expert judgment was about 93%. Sensitivities were unsatisfactory because the differentiation between educational and clinical needs requires improvement. Since the judgement concordances between the speech-language professionals was only moderate, the development of a comprehensive German reference test for speech and language disorders with evidence-based algorithmic decision rules rather than subjective clinical judgement is advocated.

  17. Integrated orbital servicing and payloads study. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A study is summarized in which a comparison was made of the following modes of maintaining a satellite system: (1) expendable mode in which failed satellites are replaced, (2) on-orbit servicing where a satellite can be fixed by unmanned module exchange in space, and (3) ground refurbishment in which the satellite is brought back to ground for repairs. It was concluded that on-orbit maintenance is the most cost-effective mode and that it is technically feasible. It can be used to repair failed satellites, to improve reliability of operating satellites, and to update equipment. On-orbit servicing can increase program flexibility and satellite reliability, lifetime, and availability. The significant conclusions and results of two studies are summarized.

  18. Terrestrial-passage theory: failing a test.

    PubMed

    Reed, Charles F; Krupinski, Elizabeth A

    2009-01-01

    Terrestrial-passage theory proposes that the 'moon' and 'sky' illusions occur because observers learn to expect an elevation-dependent transformation of visual angle. The transformation accompanies daily movement through ordinary environments of fixed-altitude objects. Celestial objects display the same visual angle at all elevations, and hence are necessarily non-conforming with the ordinary transformation. On hypothesis, observers should target angular sizes to appear greater at elevation than at horizon. However, in a sample of forty-eight observers there was no significant difference between the perceived angular size of a constellation of stars at horizon and that predicted for a specific elevation. Occurrence of the illusion was not restricted to those observers who expected angular expansion. These findings fail to support the terrestrial-passage theory of the illusion.

  19. Pressure-Relief Features of Fixed and Autotitrating Continuous Positive Airway Pressure May Impair Their Efficacy: Evaluation with a Respiratory Bench Model

    PubMed Central

    Zhu, Kaixian; Aouf, Sami; Roisman, Gabriel; Escourrou, Pierre

    2016-01-01

    Study Objectives: Pressure-relief features are aimed at improving the patient's comfort during continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea. The objective of this study was to determine the effect of these therapy features on fixed CPAP and autotitrating CPAP (APAP) treatment efficacy. Methods: Seven pressure-relief features applied by three CPAP devices were included in our study (Remstar Auto: C-Flex 3, C-Flex+ 3, A-Flex 3, P-Flex; AirSense 10: EPR 3; Prisma 20A: SoftPAP 2 and 3). In fixed CPAP, the devices were subjected to a 10-min bench-simulated obstructive apnea sequence (initial apnea-hypopnea index, AHI = 60/h) with and without pressure-relief features. In APAP, the sequence was lengthened to 4.2 h (initial AHI = 58.6/h). The residual AHI and mean/median pressure were compared with and without pressure-relief features. Results: Compared to conventional CPAP, where pressure was adjusted to be just sufficient to control the simulated obstructive events, C-Flex+ 3, P-Flex, and EPR 3 failed to normalize the breathing flow and did not reduce the AHI. The mean pressures with the three features, respectively, were 1.8, 2.6, and 2.6 cmH2O lower than the conventional CPAP. Compared to conventional APAP, similar levels of control were observed with pressure-relief features, apart from P-Flex where the delivered mean pressure was lower and residual AHI greater. The device-reported mean/median pressures in APAP with A-Flex 3, P-Flex, EPR 3, and SoftPAP 3 were higher than that measured on the bench. Conclusions: Pressure-relief features may attenuate CPAP efficacy if not adjusted for at the time of their introduction. In clinical practice, efficacy can be ensured by increasing the therapeutic pressure delivered by fixed CPAP or by enabling the pressure-relief features prior to initial pressure titration. Device-reported pressures in APAP devices with pressure relief activated may overstate delivered pressures. Citation: Zhu K, Aouf S, Roisman G, Escourrou P. Pressure-relief features of fixed and autotitrating continuous positive airway pressure may impair their efficacy: evaluation with a respiratory bench model. J Clin Sleep Med 2016;12(3):385–392. PMID:26564383

  20. Applications of mass spectrometry for quantitative protein analysis in formalin-fixed paraffin-embedded tissues

    PubMed Central

    Steiner, Carine; Ducret, Axel; Tille, Jean-Christophe; Thomas, Marlene; McKee, Thomas A; Rubbia-Brandt, Laura A; Scherl, Alexander; Lescuyer, Pierre; Cutler, Paul

    2014-01-01

    Proteomic analysis of tissues has advanced in recent years as instruments and methodologies have evolved. The ability to retrieve peptides from formalin-fixed paraffin-embedded tissues followed by shotgun or targeted proteomic analysis is offering new opportunities in biomedical research. In particular, access to large collections of clinically annotated samples should enable the detailed analysis of pathologically relevant tissues in a manner previously considered unfeasible. In this paper, we review the current status of proteomic analysis of formalin-fixed paraffin-embedded tissues with a particular focus on targeted approaches and the potential for this technique to be used in clinical research and clinical diagnosis. We also discuss the limitations and perspectives of the technique, particularly with regard to application in clinical diagnosis and drug discovery. PMID:24339433

  1. Fixed recurrence and slip models better predict earthquake behavior than the time- and slip-predictable models 1: repeating earthquakes

    USGS Publications Warehouse

    Rubinstein, Justin L.; Ellsworth, William L.; Chen, Kate Huihsuan; Uchida, Naoki

    2012-01-01

    The behavior of individual events in repeating earthquake sequences in California, Taiwan and Japan is better predicted by a model with fixed inter-event time or fixed slip than it is by the time- and slip-predictable models for earthquake occurrence. Given that repeating earthquakes are highly regular in both inter-event time and seismic moment, the time- and slip-predictable models seem ideally suited to explain their behavior. Taken together with evidence from the companion manuscript that shows similar results for laboratory experiments we conclude that the short-term predictions of the time- and slip-predictable models should be rejected in favor of earthquake models that assume either fixed slip or fixed recurrence interval. This implies that the elastic rebound model underlying the time- and slip-predictable models offers no additional value in describing earthquake behavior in an event-to-event sense, but its value in a long-term sense cannot be determined. These models likely fail because they rely on assumptions that oversimplify the earthquake cycle. We note that the time and slip of these events is predicted quite well by fixed slip and fixed recurrence models, so in some sense they are time- and slip-predictable. While fixed recurrence and slip models better predict repeating earthquake behavior than the time- and slip-predictable models, we observe a correlation between slip and the preceding recurrence time for many repeating earthquake sequences in Parkfield, California. This correlation is not found in other regions, and the sequences with the correlative slip-predictable behavior are not distinguishable from nearby earthquake sequences that do not exhibit this behavior.

  2. FUJIFILM X10 white orbs and DeOrbIt

    NASA Astrophysics Data System (ADS)

    Dietz, Henry Gordon

    2013-01-01

    The FUJIFILM X10 is a high-end enthusiast compact digital camera using an unusual sensor design. Unfortunately, upon its Fall 2011 release, the camera quickly became infamous for the uniquely disturbing "white orbs" that often appeared in areas where the sensor was saturated. FUJIFILM's first attempt at a fix was firmware released on February 25, 2012 if it had little effect. In April 2012, a sensor replacement essentially solved the problem. This paper explores the "white orb" phenomenon in detail. After FUJIFILM's attempt at a firmware fix failed, the author decided to create a post-processing tool that automatically could repair existing images. DeOrbIt was released as a free tool on March 7, 2012. To better understand the problem and how to fix it, the WWW form version of the tool logs images, processing parameters, and evaluations by users. The current paper describes the technical problem, the novel computational photography methods used by DeOrbit to repair affected images, and the public perceptions revealed by this experiment.

  3. Fixed Full Arches Supported by Tapered Implants with Knife-Edge Thread Design and Nanostructured, Calcium-Incorporated Surface: A Short-Term Prospective Clinical Study

    PubMed Central

    Bechara, Soheil; Lukosiunas, Algirdas; Kubilius, Ricardas

    2017-01-01

    Purpose. To evaluate implant survival, peri-implant bone loss, and complications affecting fixed full-arch (FFA) restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface. Methods. Between January 2013 and December 2015, all patients referred for implant-supported FFA restorations were considered for enrollment in this study. All patients received implants with a knife-edge thread design and nanostructured calcium-incorporated surface (Anyridge®, Megagen, South Korea) were restored with FFA restorations and enrolled in a recall program. The final outcomes were implant survival, peri-implant bone loss, biologic/prosthetic complications, and “complication-free” survival of restorations. Results. Twenty-four patients were selected. Overall, 215 implants were inserted (130 maxilla, 85 mandible), 144 in extraction sockets and 71 in healed ridges. Thirty-six FFAs were delivered (21 maxilla, 15 mandible): 27 were immediately loaded and 9 were conventionally loaded. The follow-up ranged from 1 to 3 years. Two fixtures failed, yielding an implant survival rate of 95.9% (patient-based). A few complications were registered, for a “complication-free” survival of restorations of 88.9%. Conclusions. FFA restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface are successful in the short term, with high survival and low complication rates; long-term studies are needed to confirm these outcomes. PMID:28246595

  4. Anticonvulsant and antipunishment effects of toluene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wood, R.W.; Coleman, J.B.; Schuler, R.

    1984-01-01

    Toluene can have striking acute behavioral effects and is subject to abuse by inhalation. To determine if its actions resemble those of drugs used in the treatment of anxiety (anxiolytics), two sets of experiments were undertaken. Inasmuch as prevention of pentylenetetrazol-induced convulsions is an identifying property of this class of agents, the authors first demonstrated that pretreatment of mice with injections of toluene delayed the onset of convulsive signs and prevented the tonic extension phase of the convulsant activity in a dose-related manner. Injections of another alkyl benzene, m-xylene, were of comparable potency to toluene. Inhalation of toluene delayed themore » time of death after pentylenetetrazol injection in a manner related to the duration and concentration of exposure; at lower convulsant doses, inhalation of moderate concentrations (EC/sub 58/, 1300 ppm) prevented death. Treatment with a benzodiazepine receptor antagonist (Ro 15-1788) failed to reduce the anticonvulsant activity of inhaled toluene. Anxiolytics also attenuate the reduction in response rate produced by punishment with electric shock. Toluene increased rates of responding suppressed by punishment when responding was maintained under a multiple fixed-interval fixed-interval punishment schedule of reinforcement. Distinct antipunishment effects were observed in rats after 2 hr of exposure to 1780 and 3000 ppm of toluene; the rate-increasing effects of toluene were related to concentration and to time after the termination of exposure. Thus, toluene and m-xylene resemble in several respects clinically useful drugs such as the benzodiazepines. 51 references, 3 figures, 2 tables.« less

  5. Employing a gain-of-function factor IX variant R338L to advance the efficacy and safety of hemophilia B human gene therapy: preclinical evaluation supporting an ongoing adeno-associated virus clinical trial.

    PubMed

    Monahan, Paul E; Sun, Junjiang; Gui, Tong; Hu, Genlin; Hannah, William B; Wichlan, David G; Wu, Zhijian; Grieger, Joshua C; Li, Chengwen; Suwanmanee, Thipparat; Stafford, Darrel W; Booth, Carmen J; Samulski, Jade J; Kafri, Tal; McPhee, Scott W J; Samulski, R Jude

    2015-02-01

    Vector capsid dose-dependent inflammation of transduced liver has limited the ability of adeno-associated virus (AAV) factor IX (FIX) gene therapy vectors to reliably convert severe to mild hemophilia B in human clinical trials. These trials also identified the need to understand AAV neutralizing antibodies and empty AAV capsids regarding their impact on clinical success. To address these safety concerns, we have used a scalable manufacturing process to produce GMP-grade AAV8 expressing the FIXR338L gain-of-function variant with minimal (<10%) empty capsid and have performed comprehensive dose-response, biodistribution, and safety evaluations in clinically relevant hemophilia models. The scAAV8.FIXR338L vector produced greater than 6-fold increased FIX specific activity compared with wild-type FIX and demonstrated linear dose responses from doses that produced 2-500% FIX activity, associated with dose-dependent hemostasis in a tail transection bleeding challenge. More importantly, using a bleeding model that closely mimics the clinical morbidity of hemophilic arthropathy, mice that received the scAAV8.FIXR338L vector developed minimal histopathological findings of synovitis after hemarthrosis, when compared with mice that received identical doses of wild-type FIX vector. Hemostatically normal mice (n=20) and hemophilic mice (n=88) developed no FIX antibodies after peripheral intravenous vector delivery. No CD8(+) T cell liver infiltrates were observed, despite the marked tropism of scAAV8.FIXR338L for the liver in a comprehensive biodistribution evaluation (n=60 animals). With respect to the role of empty capsids, we demonstrated that in vivo FIXR338L expression was not influenced by the presence of empty AAV particles, either in the presence or absence of various titers of AAV8-neutralizing antibodies. Necropsy of FIX(-/-) mice 8-10 months after vector delivery revealed no microvascular or macrovascular thrombosis in mice expressing FIXR338L (plasma FIX activity, 100-500%). These preclinical studies demonstrate a safety:efficacy profile supporting an ongoing phase 1/2 human clinical trial of the scAAV8.FIXR338L vector (designated BAX335).

  6. Clinical utility and patient perspectives on the use of extended half-life rFIXFc in the management of hemophilia B

    PubMed Central

    Miguelino, Maricel G; Powell, Jerry S

    2014-01-01

    Hemophilia B is an X-linked genetic disease caused by mutation of the gene for coagulation protein factor IX (FIX), with an incidence of approximately once every 30,000 male births in all populations and ethnic groups. When severe, the disease leads to spontaneous life threatening bleeding episodes. When untreated, most patients die from bleeding complications before 25 years of age. Current therapy requires frequent intravenous infusions of therapeutic recombinant or plasma-derived protein concentrates containing FIX. Most patients administer the infusions at home every few days, and must limit their physical activities to avoid abnormal bleeding when the FIX activity levels are below normal. After completing the pivotal Phase III clinical trial, a new therapeutic FIX preparation that has been engineered for an extended half-life in circulation, received regulatory approval in March 2014 in Canada and the US. This new FIX represents a major therapeutic advance for patients with hemophilia B. The half-life is prolonged due to fusion of the native FIX molecule with the normal constant region of immunoglobulin G. This fusion molecule then follows the normal immunoglobulin recirculation pathways through endothelial cells, resulting in prolonged times in circulation. In the clinical trials, over 150 patients successfully used eftrenonacog alfa regularly for more than 1 year to prevent spontaneous bleeding, to successfully treat any bleeding episodes, and to provide effective coagulation for major surgery. All infusions were well tolerated and effective, with no inhibitors detected and no safety concerns. This promising therapy should allow patients to use fewer infusions to maintain appropriate FIX activity levels in all clinical settings. PMID:25143713

  7. Validation of the Lupus Nephritis Clinical Indices in Childhood-Onset Systemic Lupus Erythematosus.

    PubMed

    Mina, Rina; Abulaban, Khalid; Klein-Gitelman, Marisa S; Eberhard, Barbara A; Ardoin, Stacy P; Singer, Nora; Onel, Karen; Tucker, Lori; O'neil, Kathleen; Wright, Tracey; Brooks, Elizabeth; Rouster-Stevens, Kelly; Jung, Lawrence; Imundo, Lisa; Rovin, Brad; Witte, David; Ying, Jun; Brunner, Hermine I

    2016-02-01

    To validate clinical indices of lupus nephritis activity and damage when used in children against the criterion standard of kidney biopsy findings. In 83 children requiring kidney biopsy, the Systemic Lupus Erythematosus Disease Activity Index renal domain (SLEDAI-R), British Isles Lupus Assessment Group index renal domain (BILAG-R), Systemic Lupus International Collaborating Clinics (SLICC) renal activity score (SLICC-RAS), and SLICC Damage Index renal domain (SDI-R) were measured. Fixed effects and logistic models were calculated to predict International Society of Nephrology/Renal Pathology Society (ISN/RPS) class; low-to-moderate versus high lupus nephritis activity (National Institutes of Health [NIH] activity index [AI]) score: ≤10 versus >10; tubulointerstitial activity index (TIAI) score: ≤5 versus >5; or the absence versus presence of lupus nephritis chronicity (NIH chronicity index) score: 0 versus ≥1. There were 10, 50, and 23 patients with ISN/RPS class I/II, III/IV, and V, respectively. Scores of the clinical indices did not differentiate among patients by ISN/RPS class. The SLEDAI-R and SLICC-RAS but not the BILAG-R differed with lupus nephritis activity status defined by NIH-AI scores, while only the SLEDAI-R scores differed between lupus nephritis activity status based on TIAI scores. The sensitivity and specificity of the SDI-R to capture lupus nephritis chronicity was 23.5% and 91.7%, respectively. Despite being designed to measure lupus nephritis activity, SLICC-RAS and SLEDAI-R scores significantly differed with lupus nephritis chronicity status. Current clinical indices of lupus nephritis fail to discriminate ISN/RPS class in children. Despite its shortcomings, the SLEDAI-R appears best for measuring lupus nephritis activity in a clinical setting. The SDI-R is a poor correlate of lupus nephritis chronicity. © 2016, American College of Rheumatology.

  8. Validation of the Lupus Nephritis Clinical Indices in Childhood-Onset Systemic Lupus Erythematosus

    PubMed Central

    Mina, Rina; Abulaban, Khalid; Klein-Gitelman, Marisa; Eberhard, Anne; Ardoin, Stacy; Singer, Nora; Onel, Karen; Tucker, Lori; O’Neil, Kathleen; Wright, Tracey; Brooks, Elizabeth; Rouster-Stevens, Kelly; Jung, Lawrence; Imundo, Lisa; Rovin, Brad; Witte, David; Ying, Jun; Brunner, Hermine I.

    2015-01-01

    Objective To validate clinical indices of lupus nephritis (LN) activity and damage when used in children against the criterion standard of kidney biopsy findings. Methods In 83 children requiring kidney biopsy the SLE Disease Activity Index Renal Domain (SLEDAI-R); British Isles Lupus Assessment Group index Renal Domain (BILAG-R), Systemic Lupus International Collaborating Clinics Renal Activity (SLICC-RAS) and Damage Index Renal Domain (SDI-R) were measured. Fixed effect and logistic models were done to predict International Society of Nephrology/Renal Pathology Society (ISN/RPS) class; low/moderate vs. high LN-activity [NIH Activity Index (NIH-AI) score: ≤ 10 vs. > 10; Tubulointerstitial Activity Index (TIAI) score: ≤ 5 vs. > 5) or the absence vs. presence of LN chronicity [NIH Chronicity Index (NIH-CI) score: 0 vs. ≥ 1]. Results There were 10, 50 and 23 patients with class I/II, III/IV and V, respectively. Scores of the clinical indices did not differentiate among patients by ISN/RPS class. The SLEDAI-R and SLICC-RAS but not the BILAG-R differed with LN-activity status defined by NIH-AI scores, while only the SLEDAI-R scores differed between LN-activity status based on TIAI scores. The sensitivity and specificity of the SDI-R to capture LN chronicity was 23.5% and 91.7%, respectively. Despite designed to measure LN-activity, SLICC-RAS and SLEDAI-R scores significantly differed with LN chronicity status. Conclusion Current clinical indices of LN fail to discriminate ISN/RPS Class in children. Despite its shortcomings, the SLEDAI-R appears to best for measuring LN activity in a clinical setting. The SDI-R is a poor correlate of LN chronicity. PMID:26213987

  9. Clinical comparison and performance perspective of three aligning arch wires.

    PubMed

    Evans, T J; Jones, M L; Newcombe, R G

    1998-07-01

    To clinically evaluate three commonly used orthodontic tooth aligning arch wires: 016 x 022 inch active martensitic medium force nickel titanium, 016 x 022 inch graded force active martensitic nickel titanium, and 0.0155 inch multistrand stainless steel. A prospective randomized clinical trial. Measured serial study casts of dental arches for 112 assigned arch wires from 56 consecutive patients. Analysis based on completed records for 98 arch wires and 51 patients. A consecutive sample of 56 patients requiring both upper and lower fixed appliance therapy were randomly allocated two different arch wires from a possible three under trial. Good quality impressions were taken of the dental arches at the designated serial stages of alignment (start, T0; 4 weeks, T4; 8 weeks, T8). The resultant casts were measured on a Reflex Microscope to record the change in individual tooth alignment both in three and two dimensions (horizontal plane only). The measurement error was within acceptable limits (range, 0.05 to 0.09 mm) and showed no significant bias. ANOVA statistical models were fitted to the data to adjust for a number of variables. No significant difference in aligning capability (p > 0.05), in either two or three dimensions, was demonstrated between the three arch wires in the trial. Heat activated nickel titanium arch wires failed to demonstrate a better performance than the cheaper multistrand stainless steel wires in this randomized clinical trial. The failure to demonstrate in vivo superiority at the clinical level may be due to the confounding effects of large variations in individual metabolic response. Alternatively, it may be that in routine clinical practice NiTi-type wires are not sufficiently deformed to allow their full superelastic properties to come in to play during initial alignment.

  10. Fix success and accuracy of GPS radio collars in old-growth temperate coniferous forests

    USGS Publications Warehouse

    Sager-Fradkin, Kimberly A.; Jenkins, Kurt J.; Hoffman, Robert L.; Happe, P.; Beecham, J.; Wright, R.G.

    2007-01-01

    Global Positioning System (GPS) telemetry is used extensively to study animal distribution and resource selection patterns but is susceptible to biases resulting from data omission and spatial inaccuracies. These data errors may cause misinterpretation of wildlife habitat selection or spatial use patterns. We used both stationary test collars and collared free-ranging American black bears (Ursus americanus) to quantify systemic data loss and location error of GPS telemetry in mountainous, old-growth temperate forests of Olympic National Park, Washington, USA. We developed predictive models of environmental factors that influence the probability of obtaining GPS locations and evaluated the ability of weighting factors derived from these models to mitigate data omission biases from collared bears. We also examined the effects of microhabitat on collar fix success rate and examined collar accuracy as related to elevation changes between successive fixes. The probability of collars successfully obtaining location fixes was positively associated with elevation and unobstructed satellite view and was negatively affected by the interaction of overstory canopy and satellite view. Test collars were 33% more successful at acquiring fixes than those on bears. Fix success rates of collared bears varied seasonally and diurnally. Application of weighting factors to individual collared bear fixes recouped only 6% of lost data and failed to reduce seasonal or diurnal variation in fix success, suggesting that variables not included in our model contributed to data loss. Test collars placed to mimic bear bedding sites received 16% fewer fixes than randomly placed collars, indicating that microhabitat selection may contribute to data loss for wildlife equipped with GPS collars. Horizontal collar errors of >800 m occurred when elevation changes between successive fixes were >400 m. We conclude that significant limitations remain in accounting for data loss and error inherent in using GPS telemetry in coniferous forest ecosystems and that, at present, resource selection patterns of large mammals derived from GPS telemetry should be interpreted cautiously.

  11. Impedance computed tomography using an adaptive smoothing coefficient algorithm.

    PubMed

    Suzuki, A; Uchiyama, A

    2001-01-01

    In impedance computed tomography, a fixed coefficient regularization algorithm has been frequently used to improve the ill-conditioning problem of the Newton-Raphson algorithm. However, a lot of experimental data and a long period of computation time are needed to determine a good smoothing coefficient because a good smoothing coefficient has to be manually chosen from a number of coefficients and is a constant for each iteration calculation. Thus, sometimes the fixed coefficient regularization algorithm distorts the information or fails to obtain any effect. In this paper, a new adaptive smoothing coefficient algorithm is proposed. This algorithm automatically calculates the smoothing coefficient from the eigenvalue of the ill-conditioned matrix. Therefore, the effective images can be obtained within a short computation time. Also the smoothing coefficient is automatically adjusted by the information related to the real resistivity distribution and the data collection method. In our impedance system, we have reconstructed the resistivity distributions of two phantoms using this algorithm. As a result, this algorithm only needs one-fifth the computation time compared to the fixed coefficient regularization algorithm. When compared to the fixed coefficient regularization algorithm, it shows that the image is obtained more rapidly and applicable in real-time monitoring of the blood vessel.

  12. Failing to fail: clinicians' experience of assessing underperforming dental students.

    PubMed

    Bush, H M; Schreiber, R S; Oliver, S J

    2013-11-01

    Anecdotal evidence within a UK dental school indicated that staff's grading did not always match their evaluation of students' clinical proficiency. The invalid assessment of underperforming students, which has considerable ramifications, has been reported internationally for students of nursing and medicine, but a database search revealed no accounts for dental education. To develop an understanding of clinicians' approaches to assessing underperforming dental students. Seventeen clinical staff were interviewed (eleven females, six males). Interviews were recorded and transcribed verbatim. A grounded theory methodology was used, with simultaneous data collection and analysis. The main analytical technique was constant comparison. Participants' shared basic problem was Assessing undergraduate students, expressed as how they evaluated and used the assessment system or perceived others to do so. The core category, which explains what clinical staff do to manage their difficulties with assessment, was identified as Failing to Fail and has three subcategories: Evaluating the Assessment System, Shielding the Student and Protecting Myself. This study has substantiated the complexity of failing to fail and confirmed that some causes are shared across healthcare professions, although insufficient staff discussion, the avoidance of confrontation and the impact of negative student attitude are not reported elsewhere or are minor findings. It is recommended that clinical staff receive additional training in assessment and that they are made more aware of their learning needs, their attitudes and beliefs. Increased discussion between staff about assessment and about students known to be in difficulty is essential. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. "Who Can Help Me Fix This Toy?" The Distinction between Causal Knowledge and Word Knowledge Guides Preschoolers' Selective Requests for Information

    ERIC Educational Resources Information Center

    Kushnir, Tamar; Vredenburgh, Christopher; Schneider, Lauren A.

    2013-01-01

    Preschoolers use outcomes of actions to infer causal properties of objects. We asked whether they also use them to infer others' causal abilities and knowledge. In Experiment 1, preschoolers saw 2 informants, 2 tools, and 2 broken toys. One informant (the "labeler") knew the names of the tools, but his actions failed to activate the toys. The…

  14. Kwajalein Infrastructure Prioritization Methodology

    DTIC Science & Technology

    2012-07-01

    Kwajalein are failing apart and if not fixed they could hinder or ruin the base’s ability to execute their mission. The proposed model ranks different ...their perspectives. Multiple Objective Decision Analysis (MODA) was conducted to compare the different value measures together. Since each value...measure is rated differently , it would be difficult to compare them to one another if there was no way to bring them under one type of measurement or unit

  15. DECAF - Density Estimation for Cetaceans from Passive Acoustic Fixed Sensors

    DTIC Science & Technology

    2007-01-01

    including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing...penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 2007 2. REPORT...as far as possible to leverage data that have already been collected, and classification and localization methods that have already been developed

  16. Engaging Deweyan Ethics in Health Care: Leonard Fleck's Rational Democratic Deliberation

    ERIC Educational Resources Information Center

    Lake, Danielle L.

    2013-01-01

    While the U.S. health care system is failing to serve many of its citizens, agreeing on what is wrong as well as on how to fix the system seems impossibly optimistic. Leonard Fleck attempts to do just this--to diagnose the problems and to address these problems through dialogue. Dewey's philosophy supports the direction of Fleck's work,…

  17. Use of ordinary kriging and Gaussian conditional simulation to interpolate airborne fire radiative energy density estimates

    Treesearch

    C. Klauberg; A. T. Hudak; B. C. Bright; L. Boschetti; M. B. Dickinson; R. L. Kremens; C. A. Silva

    2018-01-01

    Fire radiative energy density (FRED, J m-2) integrated from fire radiative power density (FRPD, W m-2) observations of landscape-level fires can present an undersampling problem when collected from fixed-wing aircraft. In the present study, the aircraft made multiple passes over the fire at ~3 min intervals, thus failing to observe most of the FRPD emitted as the flame...

  18. Warranty-Guarantee Application Guidelines for Air Force Ground Electronic Equipment.

    DTIC Science & Technology

    1980-02-01

    perform the on-equipment maintenance. The procedure is comparable to existing Mobile Depot Mainte- nance. The extended outage of failed equipment may be...currently computed. However, because the equipment is fixed geographically, in contrast to the mobility of avionics equipment, operating-time logs could...base environment, many other items of ground equip- ment are deployed at a remote location or, particularly in TAC, may be mobile equipment not

  19. Treatment of hemophilia B: focus on recombinant factor IX

    PubMed Central

    Franchini, Massimo; Frattini, Francesco; Crestani, Silvia; Sissa, Cinzia; Bonfanti, Carlo

    2013-01-01

    Hemophilia B is a recessive X-linked bleeding disorder characterized by deficiency of the coagulation factor IX (FIX). In hemophilia B patients the severity of the bleeding phenotype is related to the degree of the FIX defect. Hemophilia B treatment has improved greatly in the last 20 years with the introduction first of plasma-derived and then of recombinant FIX concentrates. Replacement therapy may be administered through on-demand or prophylaxis regimens, but the latter treatment modality has been shown to be superior in prevention of hemophilic arthropathy and in improvement of patients’ quality of life. The purpose of this narrative review is to summarize the current knowledge on treatment strategies for hemophilia B, focusing on recombinant FIX products either clinically used or in development. There is only one rFIX product that is licensed to treat hemophilia B patients; from the analysis of the literature data presented in this review, the authors conclude that this rFIX product has demonstrated an excellent safety profile and excellent clinical efficacy for halting and preventing bleeds in hemophilia B patients. While prophylaxis has emerged as the best therapeutic strategy for such patients because of its ability to prevent hemophilic arthropathy and to improve patients’ quality of life, the pharmacokinetically tailored dosing of rFIX is another key point when planning hemophilia B treatment, as it allows optimization of the factor concentrate usage. Further clinical studies are needed to better assess the safety and efficacy (ie, the incidence of adverse reactions and inhibitor development) of newer rFIX products. PMID:23430394

  20. [All-ceramic resin bonded fixed partial denture made of IPS hot-pressed casting porcelain restore anterior missing teeth: a three years clinical observation].

    PubMed

    Zhou, Tuan feng; Wang, Xin zhi; Zhang, Gui rong

    2011-02-18

    To clinic observation of IPS Empress2 and IPS e.max all ceramic resin bonded fixed partial dentures used in one anterior teeth lost in upper jaw or less than two anterior tooth lost in lower jaw. 22 patients, 26 restorations had been made, which included 16 single-retainer all ceramic resin bonded fixed partial dentures and 10 two-retainers all ceramic resin bonded fixed partial dentures. Secondary caries of the abutments, shade in the margin of the retainers and the integrity of the restorations had been observed at 3 months, 6 months, 1 year, 2 years and 3 years after all ceramic resin bonded fixed partial dentures having been bonded. In the 3 years of clinic observation of the anterior all ceramic resin bonded fixed partial dentures, 1 two-retainers restoration lost bond after it had been made for 3 months, a retainer of one two-retainers restoration was broken after 6 months, but they are still used after modified as one-retainer all ceramic resin bonded fixed partial dentures, 1 two-retainers restoration lost bond two year later, It was integrity and re-bonded again that was still stable. No secondary carries and no shade in margin of the retainers had been found. Their color matches with the nature teeth excellently. The success rate was 88.5%. IPS Empress 2 and IPS e.max all ceramic resin bonded fixed partial dentures should be a good selection in one or two teeth lose in anterior jaws.

  1. [Antihypertensive Efficacy of Fixed Combination Azilsartan Medoxomil / Chlorthalidone in Patients With Uncontrolled Arterial Hypertension].

    PubMed

    Kobalava, Z D; Villevalde, S V; Kulakov, V V

    2017-11-01

    To study effects of a fixed azilsartan medoxomil/chlorthalidone combination (Edarbi Clo) on clinical, ambulatory and central blood pressure (BP) in patients with uncontrolled arterial hypertension (AH)). Patients (n=25) with uncontrolled AH were given fixed azilsartan medoxomil/chlorthalidone combination (40 / 12.5 mg / day) for 4 weeks. After 4 weeks, in patients who did not achieve target BP levels the dose was increased up to 40 / 25 mg / day. Duration of the study was 12 weeks. After 12 weeks of treatment 88 % of patients achieved target clinical BP (.

  2. Single-Port Onlay Mesh Repair of Recurrent Inguinal Hernias after Failed Anterior and Laparoscopic Repairs

    PubMed Central

    Tran, Kim; Zajkowska, Marta; Lam, Vincent; Hawthorne, Wayne J.

    2015-01-01

    Background and Objectives: Despite the exponential increase in the use of laparoscopic inguinal herniorrhaphy, overall recurrence rates have remained unchanged. Therefore, a growing number of patients are presenting with recurrent hernias after conventional anterior and laparoscopic repairs have failed. This study reports our experience with single-incision laparoscopic (SIL) intraperitoneal onlay mesh (IPOM) repair of these hernias. Methods: Patients referred with two or more recurrences of inguinal hernia underwent SIL-IPOM from November 1, 2009, to June 24, 2014. A 2.5-cm infraumbilical incision was made, and an SIL port was placed intraperitoneally. Modified dissection techniques were used: chopstick and inline dissection, 5.5-mm/52-cm/30° angled laparoscope, and conventional straight dissecting instruments. The peritoneum was incised above the pubic symphysis, and dissection was continued laterally and proximally, raising the inferior flap below the previous extraperitoneal mesh while reducing any direct, indirect, femoral, or cord lipoma before placement of antiadhesive mesh, which was fixed to the pubic ramus, as well as superiorly, with nonabsorbable tacks before the inferior border was fixed with fibrin sealant. The inferior peritoneal flap was then tacked back onto the mesh. Results: Nine male patients underwent SIL-IPOM. Their mean age was 53 years and mean body mass index was 26.8 kg/m2. Mean mesh size was 275 cm2. Mean operation time was 125 minutes, with a hospital stay of 1 day. The umbilical scar length was 23 mm at the 6-week follow-up. There were no intra-/postoperative complications, port-site hernias, chronic groin pain, or recurrence of the hernia during a mean follow-up of 24 months. Conclusion: Inguinal hernias recurring after two or more failed conventional anterior and laparoscopic repairs can be safely and efficiently treated with SIL-IPOM. PMID:25848186

  3. A review of people who did not attend an epilepsy clinic and their clinical outcomes.

    PubMed

    Minshall, I; Neligan, A

    2017-08-01

    To review the clinical outcomes of people who failed to attend or failed subsequent follow up in a Primary Care based specialist epilepsy service. The case notes of 200 people who had failed to initially attend the service or subsequent follow up from 2005 to 2013 were reviewed. Clinical outcomes were determined for 152 people, with the remaining 48 having left the area. For those not attending at all, 64% had no further recorded events, a further 22% came under alternative specialist care and were managed appropriately, 6% were already in remission at the time of referral or at follow up and stayed seizure free. For people attending, but were subsequently lost to follow up, 78% were in remission, had improved seizure frequency, and normal pregnancies. In total 6% of those with poor control came under subsequent Neurological care. This study suggests that for the majority of people who fail to attend or are lost to follow up in a primary care specialist epilepsy clinic, the primary reasons appear to be that they had no further events, improved seizure control or that seizure remission has been achieved. The majority with persistent poor control came under Neurological care. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  4. EQOFIX: a combined economic and quality-of-life study of hemophilia B treatments in France.

    PubMed

    Polack, Benoît; Calvez, Thierry; Chambost, Hervé; Rothschild, Chantal; Goudemand, Jenny; Claeyssens, Ségolène; Borel-Derlon, Annie; Bardoulat, Isabelle; Maurel, Frédérique; Woronoff-Lemsi, Marie-Christine

    2015-07-01

    EQOFIX is a medicoeconomic study that analyzed the health-related quality of life (HRQoL) and costs of care of the moderate and severe forms of hemophilia B, treated on demand or by prophylaxis with either plasma-derived Factor IX (pdFIX) or recombinant FIX (rFIX). The primary objectives were evaluations of the impact of hemophilia B on HRQoL and of the costs associated with its management. The secondary objectives were evaluations of the clinical efficacy and costs of care of pdFIX and rFIX. In this observational study we included and followed for 1 year severe and moderate hemophilia B patients without inhibitor. HRQoL was evaluated through generic and disease-specific questionnaires. Information on the health resources consumed was collected every 3 months. The EQOFIX cohort was composed of 155 patients, including 51 children and 104 adults, with 114 having severe disease and 41 having moderate disease. The regimens were prophylactic for 61 and on demand for 94. Altogether, 78 were treated with rFIX and 77 with pdFIX. There was no difference in the QoL between the pdFIX and rFIX treatments. The extra cost of prophylaxis was €22,605 per bleeding event prevented. The consumption of FIX was 1.4-fold higher for the patients treated with rFIX than for the patients treated with pdFIX. Our findings in a cohort composed of 25% of the French population of moderate and severe hemophilia B patients show, with similar clinical and HRQoL results, that treatment with rFIX is more expensive than treatment with pdFIX. © 2015 The Authors. Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.

  5. Psychiatric diagnoses are not mental processes: Wittgenstein on conceptual confusion.

    PubMed

    Rosenman, Stephen; Nasti, Julian

    2012-11-01

    Empirical explanation and treatment repeatedly fail for psychiatric diagnoses. Diagnosis is mired in conceptual confusion that is illuminated by Ludwig Wittgenstein's later critique of philosophy (Philosophical Investigations). This paper examines conceptual confusions in the foundation of psychiatric diagnosis from some of Wittgenstein's important critical viewpoints. Diagnostic terms are words whose meanings are given by usages not definitions. Diagnoses, by Wittgenstein's analogy with 'games', have various and evolving usages that are connected by family relationships, and no essence or core phenomenon connects them. Their usages will change according to the demands and contexts in which they are employed. Diagnoses, like many psychological terms, such as 'reading' or 'understanding', are concepts that refer not to fixed behavioural or mental states but to complex apprehensions of the relationship of a variety of behavioural phenomena with the world. A diagnosis is a sort of concept that cannot be located in or explained by a mental process. A diagnosis is an exercise in language and its usage changes according to the context and the needs it addresses. Diagnoses have important uses but they are irreducibly heterogeneous and cannot be identified with or connected to particular mental processes or even with a unity of phenomena that can be addressed empirically. This makes understandable not only the repeated failure of empirical science to replicate or illuminate genetic, neurophysiologic, psychic or social processes underlying diagnoses but also the emptiness of a succession of explanatory theories and treatment effects that cannot be repeated or stubbornly regress to the mean. Attempts to fix the meanings of diagnoses to allow empirical explanation will and should fail as there is no foundation on which a fixed meaning can be built and it can only be done at the cost of the relevance and usefulness of diagnosis.

  6. Cyclic coordinate descent: A robotics algorithm for protein loop closure.

    PubMed

    Canutescu, Adrian A; Dunbrack, Roland L

    2003-05-01

    In protein structure prediction, it is often the case that a protein segment must be adjusted to connect two fixed segments. This occurs during loop structure prediction in homology modeling as well as in ab initio structure prediction. Several algorithms for this purpose are based on the inverse Jacobian of the distance constraints with respect to dihedral angle degrees of freedom. These algorithms are sometimes unstable and fail to converge. We present an algorithm developed originally for inverse kinematics applications in robotics. In robotics, an end effector in the form of a robot hand must reach for an object in space by altering adjustable joint angles and arm lengths. In loop prediction, dihedral angles must be adjusted to move the C-terminal residue of a segment to superimpose on a fixed anchor residue in the protein structure. The algorithm, referred to as cyclic coordinate descent or CCD, involves adjusting one dihedral angle at a time to minimize the sum of the squared distances between three backbone atoms of the moving C-terminal anchor and the corresponding atoms in the fixed C-terminal anchor. The result is an equation in one variable for the proposed change in each dihedral. The algorithm proceeds iteratively through all of the adjustable dihedral angles from the N-terminal to the C-terminal end of the loop. CCD is suitable as a component of loop prediction methods that generate large numbers of trial structures. It succeeds in closing loops in a large test set 99.79% of the time, and fails occasionally only for short, highly extended loops. It is very fast, closing loops of length 8 in 0.037 sec on average.

  7. Superior long-term survival for fixed bearing compared with mobile bearing in ligament-balanced total knee arthroplasty.

    PubMed

    Heesterbeek, P J C; van Houten, A H; Klenk, J S; Eijer, H; Christen, B; Wymenga, A B; Schuster, A J

    2018-05-01

    Only few long-term data on ligament-balanced cruciate-retaining total knee arthroplasty (CR TKA) are currently available. Either a mobile- or fixed-bearing insert can be chosen, which showed good mid-term outcome and few complications and revisions. This multi-centre retrospective cross-sectional cohort study investigated the 12-year results of primary TKA using a balancing gap technique and compared survival and clinical outcome between fixed and mobile inserts. In this retrospective cross-sectional cohort study, 557 cases of three clinics (2 Swiss, 1 Dutch) operated between 1998 and 2003 with the first series of a TKA implanted with a balanced gap technique (433 (77.7%) fixed, 124 (22.3%) mobile (anterior-posterior gliding (7-9 mm) and rotational (15°) degrees of freedom) inserts) were included for survival analysis (Kaplan-Meier, by insert type). At the 12-year follow-up (FU) examination of 189 cases, range of motion, knee society score (KSS), numeric rating scale (NRS) for pain and satisfaction were determined and radiographs were evaluated by median tests, by insert type. Of 521 cases available for analysis, 28 (5.4%; 11 fixed, 17 mobile bearing) were revised. Mean cumulative survival after 12.4 years was 97.0% (95% CI 94.7-98.4) for fixed bearings and 85.4% (95% CI 77.5-90.7) after 12.2 years for mobile bearings, p < 0.0001. Patients' mean age at 11.0 years FU (n = 189) was 78.0 (range 54.5-97.3) years. Mean total KSS was 157.8 (24-200) points, and mean passive flexion was 114° (45-150); no clinical score differed significantly between fixed and mobile bearings. This study showed a superior survival for fixed bearing compared with mobile bearing in a CR TKA using a ligament-balanced technique after more than 12 years. Clinical outcomes are excellent to good after long-term follow-up, and similar for fixed and mobile bearing. Therapeutic studies-retrospective cohort study, Level III.

  8. Migration and clinical outcome of mobile-bearing versus fixed-bearing single-radius total knee arthroplasty.

    PubMed

    Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Van Der Heide, Huub J L; Van Der Linden-Van Der Zwaag, Henrica M J; Valstar, Edward R; Nelissen, Rob G H H

    2018-04-01

    Background and purpose - Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component migration measured with radiostereometric analysis (RSA) and clinical outcome of otherwise similarly designed cemented fixed-bearing and mobile-bearing single-radius TKPs. Patients and methods - RSA measurements and clinical scores were assessed in 46 randomized patients at baseline, 6 months, 1 year, and annually thereafter up to 6 years postoperatively. A linear mixed-effects model was used to analyze the repeated measurements. Results - Both groups showed comparable migration (p = 0.3), with a mean migration at 6-year follow-up of 0.90 mm (95% CI 0.49-1.41) for the fixed-bearing group compared with 1.22 mm (95% CI 0.75-1.80) for the mobile-bearing group. Clinical outcomes were similar between groups. 1 fixed-bearing knee was revised for aseptic loosening after 6 years and 2 knees (1 in each group) were revised for late infection. 2 knees (1 in each group) were suspected for loosening due to excessive migration. Another mobile-bearing knee was revised after an insert dislocation due to failure of the locking mechanism 6 weeks postoperatively, after which study inclusion was preliminary terminated. Interpretation - Fixed-bearing and mobile-bearing single-radius TKPs showed similar migration. The latter may, however, expose patients to more complex surgical techniques and risks such as insert dislocations inherent to this rotating-platform design.

  9. Is the addition of an assisted driving Hamiltonian always useful for adiabatic evolution?

    NASA Astrophysics Data System (ADS)

    Sun, Jie; Lu, Songfeng; Li, Li

    2017-04-01

    It has been known that when an assisted driving item is added to the main system Hamiltonian, the efficiency of the resultant adiabatic evolution can be significantly improved. In some special cases, it can be seen that only through adding an assisted driving Hamiltonian can the resulting adiabatic evolution be made not to fail. Thus the additional driving Hamiltonian plays an important role in adiabatic computing. In this paper, we show that if the driving Hamiltonian is chosen inappropriately, the adiabatic computation may still fail. More importantly, we find that the adiabatic computation can only succeed if the assisted driving Hamiltonian has a relatively fixed form. This may help us understand why in the related literature all of the driving Hamiltonians used share the same form.

  10. The Significance of Meaning: Why Do Over 90% of Behavioral Neuroscience Results Fail to Translate to Humans, and What Can We Do to Fix It?

    PubMed Central

    Garner, Joseph P.

    2014-01-01

    The vast majority of drugs entering human trials fail. This problem (called “attrition”) is widely recognized as a public health crisis, and has been discussed openly for the last two decades. Multiple recent reviews argue that animals may be just too different physiologically, anatomically, and psychologically from humans to be able to predict human outcomes, essentially questioning the justification of basic biomedical research in animals. This review argues instead that the philosophy and practice of experimental design and analysis is so different in basic animal work and human clinical trials that an animal experiment (as currently conducted) cannot reasonably predict the outcome of a human trial. Thus, attrition does reflect a lack of predictive validity of animal experiments, but it would be a tragic mistake to conclude that animal models cannot show predictive validity. A variety of contributing factors to poor validity are reviewed. The need to adopt methods and models that are highly specific (i.e., which can identify true negative results) in order to complement the current preponderance of highly sensitive methods (which are prone to false positive results) is emphasized. Concepts in biomarker-based medicine are offered as a potential solution, and changes in the use of animal models required to embrace a translational biomarker-based approach are outlined. In essence, this review advocates a fundamental shift, where we treat every aspect of an animal experiment that we can as if it was a clinical trial in a human population. However, it is unrealistic to expect researchers to adopt a new methodology that cannot be empirically justified until a successful human trial. “Validation with known failures” is proposed as a solution. Thus new methods or models can be compared against existing ones using a drug that has translated (a known positive) and one that has failed (a known negative). Current methods should incorrectly identify both as effective, but a more specific method should identify the negative compound correctly. By using a library of known failures we can thereby empirically test the impact of suggested solutions such as enrichment, controlled heterogenization, biomarker-based models, or reverse-translated measures. PMID:25541546

  11. Stent revascularization restores cortical blood flow and reverses tissue hypoxia in atherosclerotic renal artery stenosis but fails to reverse inflammatory pathways or glomerular filtration rate.

    PubMed

    Saad, Ahmed; Herrmann, Sandra M S; Crane, John; Glockner, James F; McKusick, Michael A; Misra, Sanjay; Eirin, Alfonso; Ebrahimi, Behzad; Lerman, Lilach O; Textor, Stephen C

    2013-08-01

    Atherosclerotic renal artery stenosis (ARAS) is known to reduce renal blood flow, glomerular filtration rate (GFR) and amplify kidney hypoxia, but the relationships between these factors and tubulointerstitial injury in the poststenotic kidney are poorly understood. The purpose of this study was to examine the effect of renal revascularization in ARAS on renal tissue hypoxia and renal injury. Inpatient studies were performed in patients with ARAS (n=17; >60% occlusion) before and 3 months after stent revascularization, or in patients with essential hypertension (n=32), during fixed Na(+) intake and angiotensin converting enzyme/angiotensin receptors blockers Rx. Single kidney cortical, medullary perfusion, and renal blood flow were measured using multidetector computed tomography, and GFR by iothalamate clearance. Tissue deoxyhemoglobin levels (R(2)*) were measured by blood oxygen level-dependent MRI at 3T, as was fractional kidney hypoxia (percentage of axial area with R(2)*>30/s). In addition, we measured renal vein levels of neutrophil gelatinase-associated lipocalin, monocyte chemoattractant protein-1, and tumor necrosis factor-α. Pre-stent single kidney renal blood flow, perfusion, and GFR were reduced in the poststenotic kidney. Renal vein neutrophil gelatinase-associated lipocalin, tumor necrosis factor-α, monocyte chemoattractant protein-1, and fractional hypoxia were higher in untreated ARAS than in essential hypertension. After stent revascularization, fractional hypoxia fell (P<0.002) with increased cortical perfusion and blood flow, whereas GFR and neutrophil gelatinase-associated lipocalin, monocyte chemoattractant protein-1, and tumor necrosis factor-α remained unchanged. These data demonstrate that despite reversal of renal hypoxia and partial restoration of renal blood flow after revascularization, inflammatory cytokines and injury biomarkers remained elevated and GFR failed to recover in ARAS. Restoration of vessel patency alone failed to reverse tubulointerstitial damage and partly explains the limited clinical benefit of renal stenting. These results identify potential therapeutic targets for recovery of kidney function in renovascular disease.

  12. The zinc-loss effect and mobility enhancement of DUV-patterned sol-gel IGZO thin-film transistors

    NASA Astrophysics Data System (ADS)

    Wang, Kuan-Hsun; Zan, Hsiao-Wen; Soppera, Olivier

    2018-03-01

    We investigate the composition of the DUV-patterned sol-gel indium gallium zinc oxide (IGZO) thin-film transistors (TFTs) and observe a significant zinc loss effect during developing when the DUV exposure is insufficient. The zinc loss, however, is beneficial for increasing the mobility. Reducing zinc to indium composition ratio from 0.5 to 0.02 can effectively increase mobility from 0.27 to 7.30 cm2 V-1 s-1 when the gallium to indium ratio is fixed as 0.25 and the post annealing process is fixed as 300 °C for 2 h. On the other hand, an IGO TFT fails to deliver a uniform film and a reproducible TFT performance, revealing the critical role of zinc in forming homogeneous IGZO TFTs.

  13. "Tripolar" hip arthroplasty for failed hip resurfacing: nineteen years follow-up.

    PubMed

    Scheerlinck, T; Casteleyn, P P

    2001-10-01

    The authors describe the case of a 37-year-old patient who sustained a subcapital femoral neck fracture six months after ICLH double-cup hip resurfacing. As the polyethylene acetabular resurfacing component was undamaged and well fixed, a standard femoral stem with a bipolar head was inserted. The outer diameter of the bipolar head was chosen to fit the resurfacing socket. The "tripolar" hip arthroplasty has functioned well for 19 years and was revised for aseptic cup loosening. The cemented femoral stem was still well fixed and was not revised. Although the "tripolar" hip has functioned well in our case, we believe it is not indicated for metal on metal bearings. In this case the use of an appropriate modular head with a correct head-socket clearance is preferred.

  14. Financial Management of a Large Multi-site Randomized Clinical Trial

    PubMed Central

    Sheffet, Alice J.; Flaxman, Linda; Tom, MeeLee; Hughes, Susan E.; Longbottom, Mary E.; Howard, Virginia J.; Marler, John R.; Brott, Thomas G.

    2014-01-01

    Background The Carotid Revascularization Endarterectomy versus Stenting Trial (CREST) received five years’ funding ($21,112,866) from the National Institutes of Health to compare carotid stenting to surgery for stroke prevention in 2,500 randomized participants at 40 sites. Aims Herein we evaluate the change in the CREST budget from a fixed to variable-cost model and recommend strategies for the financial management of large-scale clinical trials. Methods Projections of the original grant’s fixed-cost model were compared to the actual costs of the revised variable-cost model. The original grant’s fixed-cost budget included salaries, fringe benefits, and other direct and indirect costs. For the variable-cost model, the costs were actual payments to the clinical sites and core centers based upon actual trial enrollment. We compared annual direct and indirect costs and per-patient cost for both the fixed and variable models. Differences between clinical site and core center expenditures were also calculated. Results Using a variable-cost budget for clinical sites, funding was extended by no-cost extension from five to eight years. Randomizing sites tripled from 34 to 109. Of the 2,500 targeted sample size, 138 (5.5%) were randomized during the first five years and 1,387 (55.5%) during the no-cost extension. The actual per-patient costs of the variable model were 9% ($13,845) of the projected per-patient costs ($152,992) of the fixed model. Conclusions Performance-based budgets conserve funding, promote compliance, and allow for additional sites at modest additional cost. Costs of large-scale clinical trials can thus be reduced through effective management without compromising scientific integrity. PMID:24661748

  15. Financial management of a large multisite randomized clinical trial.

    PubMed

    Sheffet, Alice J; Flaxman, Linda; Tom, MeeLee; Hughes, Susan E; Longbottom, Mary E; Howard, Virginia J; Marler, John R; Brott, Thomas G

    2014-08-01

    The Carotid Revascularization Endarterectomy versus Stenting Trial (CREST) received five years' funding ($21 112 866) from the National Institutes of Health to compare carotid stenting to surgery for stroke prevention in 2500 randomized participants at 40 sites. Herein we evaluate the change in the CREST budget from a fixed to variable-cost model and recommend strategies for the financial management of large-scale clinical trials. Projections of the original grant's fixed-cost model were compared to the actual costs of the revised variable-cost model. The original grant's fixed-cost budget included salaries, fringe benefits, and other direct and indirect costs. For the variable-cost model, the costs were actual payments to the clinical sites and core centers based upon actual trial enrollment. We compared annual direct and indirect costs and per-patient cost for both the fixed and variable models. Differences between clinical site and core center expenditures were also calculated. Using a variable-cost budget for clinical sites, funding was extended by no-cost extension from five to eight years. Randomizing sites tripled from 34 to 109. Of the 2500 targeted sample size, 138 (5·5%) were randomized during the first five years and 1387 (55·5%) during the no-cost extension. The actual per-patient costs of the variable model were 9% ($13 845) of the projected per-patient costs ($152 992) of the fixed model. Performance-based budgets conserve funding, promote compliance, and allow for additional sites at modest additional cost. Costs of large-scale clinical trials can thus be reduced through effective management without compromising scientific integrity. © 2014 The Authors. International Journal of Stroke © 2014 World Stroke Organization.

  16. Fixed or mobile-bearing total knee arthroplasty

    PubMed Central

    Huang, Chun-Hsiung; Liau, Jiann-Jong; Cheng, Cheng-Kung

    2007-01-01

    Fixed and mobile-bearing in total knee arthroplasty are still discussed controversially. In this article, biomechanical and clinical aspects in both fixed and mobile-bearing designs were reviewed. In biomechanical aspect, the mobile-bearing design has proved to provide less tibiofemoral contact stresses under tibiofemoral malalignment conditions. It also provides less wear rate in in-vitro simulator test. Patients with posterior stabilized mobile-bearing knees had more axial tibiofemoral rotation than patients with posterior stabilized fixed-bearing knees during gait as well as in a deep knee-bend activity. However, in clinical aspect, the mid-term or long-term survivorship of mobile-bearing knees has no superiority over that of fixed-bearing knees. The theoretical advantages for mobile-bearing design to provide a long-term durability have not been demonstrated by any outcome studies. Finally, the fixed-bearing design with all-polyethylene tibial component is suggested for relatively inactive, elder people. The mobile-bearing design is suggested for younger or higher-demand patients due to the potential for reduced polyethylene wear and more normal kinematics response after joint replacement. For younger surgeon, the fixed-bearing design is suggested due to less demand for surgical technique. For experienced surgeon, one familiar surgical protocol and instrumentation is suggested rather than implant design, either fixed-bearing or mobile-bearing. PMID:17204165

  17. Fixed or mobile-bearing total knee arthroplasty.

    PubMed

    Huang, Chun-Hsiung; Liau, Jiann-Jong; Cheng, Cheng-Kung

    2007-01-05

    Fixed and mobile-bearing in total knee arthroplasty are still discussed controversially. In this article, biomechanical and clinical aspects in both fixed and mobile-bearing designs were reviewed. In biomechanical aspect, the mobile-bearing design has proved to provide less tibiofemoral contact stresses under tibiofemoral malalignment conditions. It also provides less wear rate in in-vitro simulator test. Patients with posterior stabilized mobile-bearing knees had more axial tibiofemoral rotation than patients with posterior stabilized fixed-bearing knees during gait as well as in a deep knee-bend activity. However, in clinical aspect, the mid-term or long-term survivorship of mobile-bearing knees has no superiority over that of fixed-bearing knees. The theoretical advantages for mobile-bearing design to provide a long-term durability have not been demonstrated by any outcome studies. Finally, the fixed-bearing design with all-polyethylene tibial component is suggested for relatively inactive, elder people. The mobile-bearing design is suggested for younger or higher-demand patients due to the potential for reduced polyethylene wear and more normal kinematics response after joint replacement. For younger surgeon, the fixed-bearing design is suggested due to less demand for surgical technique. For experienced surgeon, one familiar surgical protocol and instrumentation is suggested rather than implant design, either fixed-bearing or mobile-bearing.

  18. FAST TRACK COMMUNICATION: Symmetry breaking, conformal geometry and gauge invariance

    NASA Astrophysics Data System (ADS)

    Ilderton, Anton; Lavelle, Martin; McMullan, David

    2010-08-01

    When the electroweak action is rewritten in terms of SU(2) gauge-invariant variables, the Higgs can be interpreted as a conformal metric factor. We show that asymptotic flatness of the metric is required to avoid a Gribov problem: without it, the new variables fail to be nonperturbatively gauge invariant. We also clarify the relations between this approach and unitary gauge fixing, and the existence of similar transformations in other gauge theories.

  19. SU-E-J-261: Statistical Analysis and Chaotic Dynamics of Respiratory Signal of Patients in BodyFix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michalski, D; Huq, M; Bednarz, G

    Purpose: To quantify respiratory signal of patients in BodyFix undergoing 4DCT scan with and without immobilization cover. Methods: 20 pairs of respiratory tracks recorded with RPM system during 4DCT scan were analyzed. Descriptive statistic was applied to selected parameters of exhale-inhale decomposition. Standardized signals were used with the delay method to build orbits in embedded space. Nonlinear behavior was tested with surrogate data. Sample entropy SE, Lempel-Ziv complexity LZC and the largest Lyapunov exponents LLE were compared. Results: Statistical tests show difference between scans for inspiration time and its variability, which is bigger for scans without cover. The same ismore » for variability of the end of exhalation and inhalation. Other parameters fail to show the difference. For both scans respiratory signals show determinism and nonlinear stationarity. Statistical test on surrogate data reveals their nonlinearity. LLEs show signals chaotic nature and its correlation with breathing period and its embedding delay time. SE, LZC and LLE measure respiratory signal complexity. Nonlinear characteristics do not differ between scans. Conclusion: Contrary to expectation cover applied to patients in BodyFix appears to have limited effect on signal parameters. Analysis based on trajectories of delay vectors shows respiratory system nonlinear character and its sensitive dependence on initial conditions. Reproducibility of respiratory signal can be evaluated with measures of signal complexity and its predictability window. Longer respiratory period is conducive for signal reproducibility as shown by these gauges. Statistical independence of the exhale and inhale times is also supported by the magnitude of LLE. The nonlinear parameters seem more appropriate to gauge respiratory signal complexity since its deterministic chaotic nature. It contrasts with measures based on harmonic analysis that are blind for nonlinear features. Dynamics of breathing, so crucial for 4D-based clinical technologies, can be better controlled if nonlinear-based methodology, which reflects respiration characteristic, is applied. Funding provided by Varian Medical Systems via Investigator Initiated Research Project.« less

  20. [The clinical evaluation of the lateral wedged insole fixed elastically on the subtalar joint of patients with osteoarthritis of the knee].

    PubMed

    Toda, Y

    2001-06-01

    We assessed the clinical efficacy of a lateral wedged insole with elastic fixation of the subtalar joint for conservative treatment of osteoarthritis of the knee. Novel insoles with elastic subtalar fixation (fixed insole) and a traditional shoe insert wedged insoles (inserted insole) were prepared. Seventy-one new female outpatients with osteoarthritis of the knee (knee OA) were treated with wedged insoles for 3 months. Randomization was performed according to birth date. The Severity Index of Lequesne, et al at the final assessment was compared with that at baseline in both the inserted and fixed insole groups. There were 37 participants in the inserted group and 34 participants in the fixed insole group. Regarding discomfort during nocturnal bed rest, 21 out of 34 (61%) participants were positive at the baseline assessment, however, only 8 out of 34 (27%) were positive at the final assessment in the fixed insole group (P = 0.033). In the fixed insole group, the number of participants complained immediate pain after walking was decreased from 28 (82%) at the baseline assessment to 17 (50%) at the final assessments (P = 0.0104). These significant differences were not found in the group with the inserted insole. Thus, clinical efficacy of lateral wedged insole may be emphasized with elastic fixation of the subtalar joint.

  1. No difference between fixed- and mobile-bearing total knee arthroplasty in activities of daily living and pain: a randomized clinical trial.

    PubMed

    Amaro, Joicemar Tarouco; Arliani, Gustavo Gonçalves; Astur, Diego Costa; Debieux, Pedro; Kaleka, Camila Cohen; Cohen, Moises

    2017-06-01

    Until now, there are no definitive conclusions regarding functional differences related to middle- and long-term everyday activities and patient pain following implantation of mobile- and fixed-platform tibial prostheses. The aim of this study was to determine whether there are middle-term differences in knee function and pain in patients undergoing fixed- and mobile-bearing total knee arthroplasty (TKA). Eligible patients were randomized into two groups: the first group received TKA implantation with a fixed tibial platform (group A); the second group received TKA with a mobile tibial platform (group B). Patients were followed up (2 years), and their symptoms and limitations in daily living activities were evaluated using the Knee Outcome Survey-Activities of Daily Living Scale (ADLS), in addition to pain evaluation assessed using the pain visual analogue scale (VAS). There were no significant differences in function and symptoms in the ADLS and VAS between the study groups. The type of platform used in TKA (fixed vs. mobile) does not change the symptoms, function or pain of patients 2 years post-surgery. Although mobile TKAs may have better short-term results, at medium- and long-term follow-up they do not present important clinical differences compared with fixed-platform TKAs. This information is important so that surgeons can choose the most suitable implant for each patient. Randomized clinical trial, Level I.

  2. Why security fails.

    PubMed

    Sem, Richard D

    2016-10-01

    When a hospital suffers a serious loss or act of violence, the blame frequently centers on the facility's Security Department, but, as the author, a longtime security consultant, points out, there's plenty of blame to go around--including Administration at all levels, and employees, both clinical and non clinical. In this article, he presents the many reasons why security can fail and what should be done to prevent such failure.

  3. Clinical factors associated with failed trials of labor in late preterm and term twin pregnancies.

    PubMed

    Ko, Hyun-Joo; Jun, Jong Kwan

    2014-07-01

    To evaluate the perinatal outcomes and clinical factors of unsuccessful trials of labor (TOLs) in late preterm and term twin pregnancies. We enrolled 896 consecutive twin pregnancies delivered between 1999 and 2012 in a single center, which met the following inclusion criteria: a vertex first twin, live twins, and attempted TOLs after 34 weeks. Obstetric characteristics and perinatal outcomes were compared between vaginal delivery and cesarean delivery groups. Successful TOLs were carried out in 81% (726/896). Failed TOLs occurred in 15% (37/247) of late preterm twins and 20% (133/649) of term twins. Comparisons of neonatal outcomes between the groups showed no significant differences in NICU admission, ventilator use, and composite morbidity. On univariable analysis, nulliparity, preeclampsia, induced labor, excessive weight gain, and intertwin weight discordance of >30% showed significant associations with failed TOLs. Multivariable analyses revealed nulliparity (adjusted odds ratio 9.89, 95% confidence interval 4.64-21.1) and preeclampsia (adjusted odds ratio 2.17, 95% confidence interval 1.30-3.63) as significantly associated with failed TOLs. In late preterm and term twins, trials of labor can be performed successfully without a significant increase in adverse neonatal outcomes. Nulliparity and preeclampsia are clinical factors associated with failed TOLs in twin pregnancies.

  4. The Risk Factors and Clinical Course of Asthma with Fixed Airflow Limitation.

    PubMed

    Pothirat, Chaicharn; Chaiwong, Warawut; Liwsrisakun, Chalerm; Bumroongkit, Chaiwat; Deesomchok, Athavudh; Theerakittikul, Theerakorn; Limsukon, Atikun; Phetsuk, Nittaya

    2016-07-01

    To identify risk factors and clinical course of asthma with fixed airflow limitation. A retrospective case-control study of asthma patients was conducted over a 15-month period. Asthma with fixed airflow limitation patients were defined as chronic asthmatics who had both post-bronchodilator (BD) and on-treatment ratio of forced expiratory in first second (FEV1)/forced vital capacity (FVC) persistently less than 0.7, whereas usual chronic asthma patients had post-BD and/or on-treatment ratio of FEV1/FVC more than 0.7. Serial asthma control tests (ACT), medication used, exacerbations were assessed. The risk factors were analyzed using logistic regression. Clinical characteristics between groups were compared using Student’s t-test and Fisher’s exact test. One hundred twenty from 142 eligible subjects were enrolled. They had asthma with fixed airflow limitation (n = 40) and usual chronic asthma (n = 80). Potential risk factors of asthma with fixed airflow limitation included early disease onset (age <15 years) [(adjusted odd ratio (OR) = 3.9, 95% confidence interval (CI) 1.9-8.3)] with longer disease duration (adjusted OR = 8.4, 95% CI 4.6-15.4 for >30 years). Asthma with fixed airflow limitation patients had lower ACT scores (p<0.001), lower level of asthma control (p<0.001), required more asthma medications (p = 0.002), and higher rates of hospitalization (p = 0.001) than usual chronic asthma. The potential risk factors of asthma with fixed airflow limitation were earlier disease onset and longer disease duration. They had poorer asthma control, more medications needed, and higher rates of exacerbation than usual chronic asthma.

  5. Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures.

    PubMed

    Barber, F Alan; Coons, David A; Ruiz-Suarez, Michell

    2007-04-01

    The purpose of this study was to test 4 different biodegradable suture anchors threaded with 2 high-strength sutures under cyclic loading conditions in humeral cadaveric specimens divided into 2 different age groups. Thirty-two paired human cadaveric humeri were stripped of all soft tissue. Two groups were studied: group 1, in which the mean age was 54 years, and group 2, in which the mean age was 70 years. We placed 1 suture anchor at 3 humeral sites per bone (anterior, middle, and posterior greater tuberosity). We tested 24 specimens using each of 4 anchors: TwinFix AB (Smith & Nephew Endoscopy, Andover, MA), BioZip (Stryker Endoscopy, San Jose, CA), Bio-Corkscrew FT (Arthrex, Naples, FL), and SpiraLok (DePuy Mitek, Raynham, MA). The anchor's sutures were grasped with an Instron clamp (Instron, Canton, MA), preloaded, and cycled from 10 to 60 N 500 times, followed by destructive testing. The mean displacement at 500 cycles, yield loads, failure modes, and ultimate loads were recorded. Most cyclic motion occurred during the first 100 cycles. More motion occurred in older bones than in younger bones (P < .05). The mean yield loads were greater for the young group for the SpiraLok anchors than for Bio-Corkscrew FT anchors in the young and old groups (P < .001), TwinFix anchors in the old group (P < .05), and BioZip anchors in the old group (P < .05). The ultimate failure loads for SpiraLok anchors in the young group were greater than for Bio-Corkscrew FT anchors in the young and old groups and BioZip anchors in the old group (P < .05). In group 1 TwinFix AB (P = .01) and BioZip (P = .02) ultimate loads were statistically greater than that for Bio-Corkscrew FT. The TwinFix AB failed by anchor pullout. The Bio-Corkscrew FT failed by eyelet pullout. The BioZip and SpiraLok pulled out in older bone and experienced eyelet breakage in younger bone. None of the 4 anchors reached 5 mm of displacement even after 500 loading cycles. Most of the displacement occurred in the first 100 cycles. Of all anchors tested, the Bio-Corkscrew FT recorded the lowest displacement after 500 cycles (P < .05). The SpiraLok had the highest ultimate load of all anchors tested (P < .01). Rotator cuff anchors perform differently in younger humeral bone than in older humeral bone. Most displacement with cyclic loading occurring between the anchor and bone takes place in the first 100 cycles. Anchors in older bones can be expected to fail at lower loads.

  6. Collagen Type IV and Laminin Expressions during Cartilage Repair and in Late Clinically Failed Repair Tissues from Human Subjects

    PubMed Central

    Foldager, Casper Bindzus; Toh, Wei Seong; Christensen, Bjørn Borsøe; Lind, Martin; Gomoll, Andreas H.; Spector, Myron

    2016-01-01

    Objective To identify the collagen type IV (Col4) isoform in articular cartilage and to evaluate the expressions of Col4 and laminin in the pericellular matrix (PCM) in damaged cartilage and during cartilage repair. Design The Col4 isoform was determined in chondrocytes isolated from 6 patients cultured up to 6 days and in 21% O2 or 1% O2, and the gene expression of Col4 α-chains was investigated. The distribution of Col4 and laminin in traumatically damaged cartilage (n = 7) and clinically failed cartilage repair (microfracture, TruFit, autologous chondrocyte implantation; n = 11) were investigated using immunohistochemistry. Normal human cartilage was used as control (n = 8). The distribution during clinical cartilage repair procedures was investigated in a minipig model with 6-month follow-up (untreated chondral, untreated osteochondral, microfracture, autologous chondrocyte implantation; n = 10). Results The Col4 isoform in articular cartilage was characterized as α1α1α2, which is an isoform containing antiangiogenic domains in the NC1-terminals (arresten and canstatin). In normal cartilage, laminin and Col4 was exclusively found in the PCM. High amounts (>50%) of Col4 in the PCM significantly decreased in damaged cartilage (P = 0.004) and clinically failed repair tissue (P < 0.001). Laminin was only found with high expression (>50%) in 4/8 of the normal samples, which was not statistically significantly different from damaged cartilage (P = 0.15) or failed cartilage repair (P = 0.054). Conclusions Col4 in cartilage contain antiangiogenic domains and may play a role in the hypoxic environment in articular cartilage. Col4 and laminin was not found in the PCM of damaged and clinically failed repair. PMID:26958317

  7. Migration and clinical outcome of mobile-bearing versus fixed-bearing single-radius total knee arthroplasty

    PubMed Central

    Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Van Der Heide, Huub J L; Van Der Linden-Van Der Zwaag, Henrica M J; Valstar, Edward R; Nelissen, Rob G H H

    2018-01-01

    Background and purpose Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component migration measured with radiostereometric analysis (RSA) and clinical outcome of otherwise similarly designed cemented fixed-bearing and mobile-bearing single-radius TKPs. Patients and methods RSA measurements and clinical scores were assessed in 46 randomized patients at baseline, 6 months, 1 year, and annually thereafter up to 6 years postoperatively. A linear mixed-effects model was used to analyze the repeated measurements. Results Both groups showed comparable migration (p = 0.3), with a mean migration at 6-year follow-up of 0.90 mm (95% CI 0.49–1.41) for the fixed-bearing group compared with 1.22 mm (95% CI 0.75–1.80) for the mobile-bearing group. Clinical outcomes were similar between groups. 1 fixed-bearing knee was revised for aseptic loosening after 6 years and 2 knees (1 in each group) were revised for late infection. 2 knees (1 in each group) were suspected for loosening due to excessive migration. Another mobile-bearing knee was revised after an insert dislocation due to failure of the locking mechanism 6 weeks postoperatively, after which study inclusion was preliminary terminated. Interpretation Fixed-bearing and mobile-bearing single-radius TKPs showed similar migration. The latter may, however, expose patients to more complex surgical techniques and risks such as insert dislocations inherent to this rotating-platform design. PMID:29448880

  8. Sinus floor elevation with a crestal approach using a press-fit bone block: a case series.

    PubMed

    Isidori, M; Genty, C; David-Tchouda, S; Fortin, T

    2015-09-01

    This prospective study aimed to provide detailed clinical information on a sinus augmentation procedure, i.e., transcrestal sinus floor elevation with a bone block using the press-fit technique. A bone block is harvested with a trephine burr to obtain a cylinder. This block is inserted into the antrum via a crestal approach after creation of a circular crestal window. Thirty-three patients were treated with a fixed prosthesis supported by implants placed on 70 cylindrical bone blocks. The mean bone augmentation was 6.08±2.87 mm, ranging from 0 to 12.7 mm. Only one graft failed before implant placement. During surgery and the subsequent observation period, no complications were recorded, one implant was lost, and no infection or inflammation was observed. This proof-of-concept study suggests that the use of a bone block inserted into the sinus cavity via a crestal approach can be an alternative to the sinus lift procedure with the creation of a lateral window. It reduces the duration of surgery, cost of treatment, and overall discomfort. Copyright © 2015. Published by Elsevier Ltd.

  9. To pass or to fail? Understanding the factors considered by faculty in the clinical evaluation of nursing students.

    PubMed

    DeBrew, Jacqueline Kayler; Lewallen, Lynne Porter

    2014-04-01

    Making the decision to pass or to fail a nursing student is difficult for nurse educators, yet one that all educators face at some point in time. To make this decision, nurse educators draw from their past experiences and personal reflections on the situation. Using the qualitative method of critical incident technique, the authors asked educators to describe a time when they had to make a decision about whether to pass or fail a student in the clinical setting. The findings describe student and faculty factors important in clinical evaluation decisions, demonstrate the benefits of reflective practice to nurse educators, and support the utility of critical incident technique not only as research methodology, but also as a technique for reflective practice. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Exploring the issue of failure to fail in a nursing program.

    PubMed

    Larocque, Sylvie; Luhanga, Florence Loyce

    2013-05-18

    A study using a qualitative descriptive design was undertaken to explore the issue of "failure to fail" in a nursing program. Individual in-depth interviews were conducted with nursing university faculty members, preceptors, and faculty advisors (n=13). Content analysis was used to analyze the data. Results indicate that: (a) failing a student is a difficult process; (b) both academic and emotional support are required for students and preceptors and faculty advisors; (c) there are consequences for programs, faculty, and students when a student has failed a placement; (d) at times, personal, professional, and structural reasons exist for failing to fail a student; and (e) the reputation of the professional program can be diminished as a result of failing to fail a student. Recommendations for improving assessment, evaluation, and intervention with a failing student include documentation, communication, and support. These findings have implications for improving the quality of clinical experiences.

  11. Patients With Failed Prior Two-Stage Exchange Have Poor Outcomes After Further Surgical Intervention.

    PubMed

    Kheir, Michael M; Tan, Timothy L; Gomez, Miguel M; Chen, Antonia F; Parvizi, Javad

    2017-04-01

    Failure of 2-stage exchange arthroplasty for the management of periprosthetic joint infection (PJI) poses a major clinical challenge. There is a paucity of information regarding the outcomes of further surgical intervention in these patients. Thus, we aim to report the clinical outcomes of subsequent surgery for a failed prior 2-stage exchange arthroplasty. Our institutional database was used to identify 60 patients (42 knees and 18 hips), with a failed prior 2-stage exchange, who underwent further surgical intervention between 1998 and 2012, and had a minimum 2-year follow-up. A retrospective review was performed to extract relevant clinical information, including mortality, microbiology, and subsequent surgeries. Musculoskeletal Infection Society criteria were used to define PJI, and treatment success was defined using Delphi criteria. Irrigation and debridement (I&D) was performed after a failed 2-stage exchange in 61.7% of patients; 56.8% subsequently failed. Forty patients underwent an intended second 2-stage exchange; 6 cases required a spacer exchange. Reimplantation occurred only in 65% of cases, and 61.6% had infection controlled. The 14 cases that were not reimplanted resulted in 6 retained spacers, 5 amputations, 2 PJI-related mortalities, and 1 arthrodesis. Further surgical intervention after a failed prior 2-stage exchange arthroplasty has poor outcomes. Although I&D has a high failure rate, many patients who are deemed candidates for a second 2-stage exchange either do not undergo reimplantation or fail after reimplantation. The management of PJI clearly remains imperfect, and there is a dire need for further innovations that may improve the care of these patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. A low-dose β1-blocker in combination with milrinone improves intracellular Ca2+ handling in failing cardiomyocytes by inhibition of milrinone-induced diastolic Ca2+ leakage from the sarcoplasmic reticulum.

    PubMed

    Kobayashi, Shigeki; Susa, Takehisa; Ishiguchi, Hironori; Myoren, Takeki; Murakami, Wakako; Kato, Takayoshi; Fukuda, Masakazu; Hino, Akihiro; Suetomi, Takeshi; Ono, Makoto; Uchinoumi, Hitoshi; Tateishi, Hiroki; Mochizuki, Mamoru; Oda, Tetsuro; Okuda, Shinichi; Doi, Masahiro; Yamamoto, Takeshi; Yano, Masafumi

    2015-01-01

    The purpose of this study was to investigate whether adding a low-dose β1-blocker to milrinone improves cardiac function in failing cardiomyocytes and the underlying cardioprotective mechanism. The molecular mechanism underlying how the combination of low-dose β1-blocker and milrinone affects intracellular Ca(2+) handling in heart failure remains unclear. We investigated the effect of milrinone plus landiolol on intracellular Ca(2+) transient (CaT), cell shortening (CS), the frequency of diastolic Ca(2+) sparks (CaSF), and sarcoplasmic reticulum Ca(2+) concentration ({Ca(2+)}SR) in normal and failing canine cardiomyocytes and used immunoblotting to determine the phosphorylation level of ryanodine receptor (RyR2) and phospholamban (PLB). In failing cardiomyocytes, CaSF significantly increased, and peak CaT and CS markedly decreased compared with normal myocytes. Administration of milrinone alone slightly increased peak CaT and CS, while CaSF greatly increased with a slight increase in {Ca(2+)}SR. Co-administration of β1-blocker landiolol to failing cardiomyocytes at a dose that does not inhibit cardiomyocyte function significantly decreased CaSF with a further increase in {Ca(2+)}SR, and peak CaT and CS improved compared with milrinone alone. Landiolol suppressed the hyperphosphorylation of RyR2 (Ser2808) in failing cardiomyocytes but had no effect on levels of phosphorylated PLB (Ser16 and Thr17). Low-dose landiolol significantly inhibited the alternans of CaT and CS under a fixed pacing rate (0.5 Hz) in failing cardiomyocytes. A low-dose β1-blocker in combination with milrinone improved cardiac function in failing cardiomyocytes, apparently by inhibiting the phosphorylation of RyR2, not PLB, and subsequent diastolic Ca(2+) leak.

  13. A Low-Dose β1-Blocker in Combination with Milrinone Improves Intracellular Ca2+ Handling in Failing Cardiomyocytes by Inhibition of Milrinone-Induced Diastolic Ca2+ Leakage from the Sarcoplasmic Reticulum

    PubMed Central

    Kobayashi, Shigeki; Susa, Takehisa; Ishiguchi, Hironori; Myoren, Takeki; Murakami, Wakako; Kato, Takayoshi; Fukuda, Masakazu; Hino, Akihiro; Suetomi, Takeshi; Ono, Makoto; Uchinoumi, Hitoshi; Tateishi, Hiroki; Mochizuki, Mamoru; Oda, Tetsuro; Okuda, Shinichi; Doi, Masahiro; Yamamoto, Takeshi; Yano, Masafumi

    2015-01-01

    Objectives The purpose of this study was to investigate whether adding a low-dose β1-blocker to milrinone improves cardiac function in failing cardiomyocytes and the underlying cardioprotective mechanism. Background The molecular mechanism underlying how the combination of low-dose β1-blocker and milrinone affects intracellular Ca2+ handling in heart failure remains unclear. Methods We investigated the effect of milrinone plus landiolol on intracellular Ca2+ transient (CaT), cell shortening (CS), the frequency of diastolic Ca2+ sparks (CaSF), and sarcoplasmic reticulum Ca2+ concentration ({Ca2+}SR) in normal and failing canine cardiomyocytes and used immunoblotting to determine the phosphorylation level of ryanodine receptor (RyR2) and phospholamban (PLB). Results In failing cardiomyocytes, CaSF significantly increased, and peak CaT and CS markedly decreased compared with normal myocytes. Administration of milrinone alone slightly increased peak CaT and CS, while CaSF greatly increased with a slight increase in {Ca2+}SR. Co-administration of β1-blocker landiolol to failing cardiomyocytes at a dose that does not inhibit cardiomyocyte function significantly decreased CaSF with a further increase in {Ca2+}SR, and peak CaT and CS improved compared with milrinone alone. Landiolol suppressed the hyperphosphorylation of RyR2 (Ser2808) in failing cardiomyocytes but had no effect on levels of phosphorylated PLB (Ser16 and Thr17). Low-dose landiolol significantly inhibited the alternans of CaT and CS under a fixed pacing rate (0.5 Hz) in failing cardiomyocytes. Conclusion A low-dose β1-blocker in combination with milrinone improved cardiac function in failing cardiomyocytes, apparently by inhibiting the phosphorylation of RyR2, not PLB, and subsequent diastolic Ca2+ leak. PMID:25614983

  14. Phosphate assimilation in Rhizobium (Sinorhizobium) meliloti: identification of a pit-like gene.

    PubMed

    Bardin, S D; Voegele, R T; Finan, T M

    1998-08-01

    Rhizobium meliloti mutants defective in the phoCDET-encoded phosphate transport system form root nodules on alfalfa plants that fail to fix nitrogen (Fix-). We have previously reported that two classes of second-site mutations can suppress the Fix- phenotype of phoCDET mutants to Fix+. Here we show that one of these suppressor loci (sfx1) contains two genes, orfA and pit, which appear to form an operon transcribed in the order orfA-pit. The Pit protein is homologous to various phosphate transporters, and we present evidence that three suppressor mutations arose from a single thymidine deletion in a hepta-thymidine sequence centered 54 nucleotides upstream of the orfA transcription start site. This mutation increased the level of orfA-pit transcription. These data, together with previous biochemical evidence, show that the orfA-pit genes encode a Pi transport system that is expressed in wild-type cells grown with excess Pi but repressed in cells under conditions of Pi limitation. In phoCDET mutant cells, orfA-pit expression is repressed, but this repression is alleviated by the second-site suppressor mutations. Suppression increases orfA-pit expression compensating for the deficiencies in phosphate assimilation and symbiosis of the phoCDET mutants.

  15. [Indications and Borderline Indications for Medial Mobile Bearing Unicondylar Knee Replacement].

    PubMed

    Walker, T; Streit, M R; Streit, J; Gotterbarm, T; Aldinger, P R

    2015-10-01

    Beside the possibility of bicondylar knee replacement, patients with isolated anteromedial osteoarthritis also have the possibility of unicondylar knee replacement. Therefore some requirements are essential such as functionally intact cruciate and collateral ligaments, intact cartilage in the lateral compartment and an intraoperative flexion of more than 100°. An instability or contracture of the cruciate or collateral ligaments, a varus deformity more than 15°, a flexion deformity of more than 15°, an intraoperative flexion less than 100° as well as failed upper tibial osteotomy are seen as contraindications. In addition, a rheumatoid arthritis and a full thickness cartilage defect in the central part of the lateral compartment are seen as a contraindication because of the risk of a progression of the disease. With respect to these contraindications, excellent functional outcome and survival rates could be demonstrated in the long term. An expansion of these criteria, especially in patients with an insufficiency of the cruciate ligaments or after failed upper tibial osteotomy should only be done in certain cases after careful assessment of the benefits and risks. These patients should be informed about the lack of long-term results and the higher risk of complications. Quite commonly, the criteria of Kozinn and Scott are used for patient selection. These criteria were originally established for fixed-bearing prosthesis and have no relevance on mobile-bearing prosthesis. Criteria such as age, level of activity, weight, chondrocalcinosis and anterior knee pain have no effect on the clinical outcome or the long-term survival of a mobile-bearing prosthesis. Georg Thieme Verlag KG Stuttgart · New York.

  16. Coracoid bypass procedure: surgical technique for coracoclavicular reconstruction with coracoid insufficiency.

    PubMed

    Virk, Mandeep S; Lederman, Evan; Stevens, Christopher; Romeo, Anthony A

    2017-04-01

    Failed acromioclavicular (AC) joint reconstruction secondary to a coracoid fracture or insufficiency of the coracoid is an uncommon but challenging clinical situation. We describe a surgical technique of revision coracoclavicular (CC) reconstruction, the coracoid bypass procedure, and report short-term results with this technique in 3 patients. In the coracoid bypass procedure, reconstruction of the CC ligaments is performed by passing a tendon graft through a surgically created bone tunnel in the scapular body (inferior to the base of the coracoid) and then fixing the graft around the clavicle or through bone tunnels in the clavicle. Three patients treated with this technique were retrospectively reviewed. AC joint reconstruction performed for a traumatic AC joint separation failed in the 3 patients reported in this series. The previous procedures were an anatomic CC reconstruction in 2 patients and a modified Weaver-Dunn procedure in 1 patient. The coracoid fractures were detected postoperatively, and the mean interval from the index surgery to the coracoid bypass procedure was 8 months. The patients were a mean age of 44 years, and average follow-up was 21 months. At the last follow-up, all 3 patients were pain free, with full range of shoulder motion, preserved CC distance, and a stable AC joint. The coracoid bypass procedure is a treatment option for CC joint reconstruction during revision AC joint surgery in the setting of a coracoid fracture or coracoid insufficiency. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Reducing motion artifacts for long-term clinical NIRS monitoring using collodion-fixed prism-based optical fibers

    PubMed Central

    Yücel, Meryem A.; Selb, Juliette; Boas, David A.; Cash, Sydney S.; Cooper, Robert J.

    2013-01-01

    As the applications of near-infrared spectroscopy (NIRS) continue to broaden and long-term clinical monitoring becomes more common, minimizing signal artifacts due to patient movement becomes more pressing. This is particularly true in applications where clinically and physiologically interesting events are intrinsically linked to patient movement, as is the case in the study of epileptic seizures. In this study, we apply an approach common in the application of EEG electrodes to the application of specialized NIRS optical fibers. The method provides improved optode-scalp coupling through the use of miniaturized optical fiber tips fixed to the scalp using collodion, a clinical adhesive. We investigate and quantify the performance of this new method in minimizing motion artifacts in healthy subjects, and apply the technique to allow continuous NIRS monitoring throughout epileptic seizures in two epileptic in-patients. Using collodion-fixed fibers reduces the percent signal change of motion artifacts by 90 % and increases the SNR by 6 and 3 fold at 690 and 830 nm wavelengths respectively when compared to a standard Velcro-based array of optical fibers. The change in both HbO and HbR during motion artifacts is found to be statistically lower for the collodion-fixed fiber probe. The collodion-fixed optical fiber approach has also allowed us to obtain good quality NIRS recording of three epileptic seizures in two patients despite excessive motion in each case. PMID:23796546

  18. Failure analysis of stainless steel femur fixation plate.

    PubMed

    Hussain, P B; Mohammad, M

    2004-05-01

    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.

  19. Radar Imaging for Urban Sensing

    DTIC Science & Technology

    2010-04-01

    waveforms, we fix the input SNR to the matched filter in all cases. The noise variance may be obtained as, 97 ^ l ^feo (20) where Pmax is the highest...maximum likelihood, and cramer-rao bound," IEEE Trans. Acoust., Speech, Signal Processing, vol. 37, no. 5, pp. 720-741, May 1989. [16] L . Frazier...it may fail to work when directly applied to extended targets or target returns of low SNR. The Beamspace MUSIC (BS-MUSIC), in which the MUSIC

  20. Clinical relevance of diagnosing COPD by fixed ratio or lower limit of normal: a systematic review.

    PubMed

    van Dijk, Wouter D; Gupta, Nisha; Tan, Wan C; Bourbeau, Jean

    2014-02-01

    Different spirometric criteria in diagnosing COPD have been advocated by different groups, debilitating adequate diagnosis and treatment of COPD. We reviewed the clinical relevance of fixed ratio and lower limit of normal (LLN) in diagnosing COPD and explored if modifying factors may affect their clinical relevance. Two reviewers independently searched PubMed and Embase for papers that compared both criteria on any clinically relevant outcome, published before June 1st, 2012, without any language restriction. Two reviewers independently extracted the study characteristics, including study design, population characteristics and diagnostic criteria used, and summarized the results of clinical relevance. Study quality was assessed by scoring forms for bias and level of evidence. Of 394 studies retrieved, 11 studies were included, with a median of 1,258 participants. Although both criteria appeared related with various clinically relevant outcomes, we were unable to prefer one criterion over the other, with various performances of the criteria for different outcomes. Should the criteria disagree on diagnosis, an alternative diagnosis should be suspected, in particular in those (elderly) with less severe airflow limitation for whom the LLN appears a better criterion. The fixed ratio appears to perform better in subjects with more severe airflow limitation. In diagnosing COPD, severity of airflow limitation appears an important factor for choosing whether the fixed ratio or LLN. Disagreement between the criteria is suggestive for an alternative diagnosis. Future studies on clinical relevance should further reveal the criterion of choice, in order to improve adequate diagnosis and consequent treatments.

  1. Nebivolol and valsartan as a fixed-dose combination for the treatment of hypertension.

    PubMed

    Sander, Gary E; Giles, Thomas D

    2015-04-01

    The fixed-dose combination of nebivolol and valsartan drug has been clinically evaluated and demonstrated to represent a unique combination of nebivolol, a selective β1-adrenoceptor antagonist and a β3-adrenoceptor agonist; β3 receptor activation increases endothelial nitric oxide and produces vasodilation. Valsartan is highly selective angiotensin AT1 receptor blocker and exerts its major pharmacological effect by decreasing angiotensin II-induced vasoconstriction and production of aldosterone. The addition of nebivolol counteracts the effects of increased angiotensin II concentrations resulting from potent AT1 blockade. This review describes a recently completed trial establishing the efficacy of the nebivolol/valsartan combination. This review provides a literature search of pertinent pharmacological and clinical data that describes the mechanisms of both drugs individually and the results of a clinical trial comparing fixed-dose combinations of nebivolol with valsartan as compared with each drug as monotherapy. Fixed-dose combination drugs are intended to improve patient compliance and reduce drug costs, as well as to reduce long-term cardiovascular event rates and block counter-regulatory effects due to monotherapy. The vast majority of hypertensive patients will require at least two medications. We believe that the clinical evidence suggests that the combination of nebivolol with valsartan offers a definite clinical benefit, combining β1-adrenoceptor and angiotensin AT1 receptor blockade with β3 receptor activation and resultant increase in nitric oxide and vasodilation.

  2. The succinonitrile triple-point standard: a fixed point to improve the accuracy of temperature measurements in the clinical laboratory.

    PubMed

    Mangum, B W

    1983-07-01

    In an investigation of the melting and freezing behavior of succinonitrile, the triple-point temperature was determined to be 58.0805 degrees C, with an estimated uncertainty of +/- 0.0015 degrees C relative to the International Practical Temperature Scale of 1968 (IPTS-68). The triple-point temperature of this material is evaluated as a temperature-fixed point, and some clinical laboratory applications of this fixed point are proposed. In conjunction with the gallium and ice points, the availability of succinonitrile permits thermistor thermometers to be calibrated accurately and easily on the IPTS-68.

  3. Orthodontically induced external apical root resorption in patients treated with fixed appliances vs removable aligners.

    PubMed

    Iglesias-Linares, Alejandro; Sonnenberg, Boris; Solano, Beatriz; Yañez-Vico, Rosa-Maria; Solano, Enrique; Lindauer, Steven J; Flores-Mir, Carlos

    2017-01-01

    To determine whether orthodontic treatment with removable aligners vs fixed orthodontic appliances is associated with a different frequency of orthodontically induced external apical root resorption (OIEARR) when genetic, radiographic, and clinical factors are accounted for. Three hundred seventy-two orthodontic patients treated with removable aligners (Invisalign) or fixed appliances were genetically screened for interleukin 1B gene (IL1B) (rs1143634), interleukin 1 receptor antagonist gene (IL1RN) (rs419598), and osteopontin gene (SPP1) (rs9138/rs11730582). Twelve clinical variables, potentially associated with OIEARR, were also considered. Subjects were divided according to the presence of radiographically determined OIEARR (>2 mm). The association between OIEARR and appliance type, and radiographic, clinical and genetic factors, was assessed using backward stepwise conditional logistic regression. Odds ratios (ORs) and 95% confidence intervals (CIs) were reported. Reliability of the methods was adequate. Clinical case complexity (American Board of Orthodontics [ABO] Discrepancy Index) (OR: 1.032; 95% CI: 1.005-1.061; P = .021) and extent of incisor apical displacement in the sagittal plane (OR: 1.478; 95% CI: 1.285-1.699; P = .001) were associated with an increased OIEARR risk. After adjusting for associations between clinical/radiographic/genetic factors, there were no statistically significant differences with respect to OIEARR or type of orthodontic appliance used, whether removable aligners or fixed appliances (OR: 1.662; 95% CI: 0.945-2.924; P = .078). Only subjects homozygous for the T allele of IL1RN (rs419598) were more prone to OIEARR during orthodontic treatment (OR: 3.121; CI: 1.93-5.03; P < .001). A similar OIEARR predisposition was identified using either removable aligners (Invisalign) or fixed appliances.

  4. The Causal Effects of Father Absence

    PubMed Central

    McLanahan, Sara; Tach, Laura; Schneider, Daniel

    2014-01-01

    The literature on father absence is frequently criticized for its use of cross-sectional data and methods that fail to take account of possible omitted variable bias and reverse causality. We review studies that have responded to this critique by employing a variety of innovative research designs to identify the causal effect of father absence, including studies using lagged dependent variable models, growth curve models, individual fixed effects models, sibling fixed effects models, natural experiments, and propensity score matching models. Our assessment is that studies using more rigorous designs continue to find negative effects of father absence on offspring well-being, although the magnitude of these effects is smaller than what is found using traditional cross-sectional designs. The evidence is strongest and most consistent for outcomes such as high school graduation, children’s social-emotional adjustment, and adult mental health. PMID:24489431

  5. A galactopoiesis accordant yield of functional recombinant human factor IX from homozygous transgenic pigs requires a large amount of vitamin K supplementation.

    PubMed

    Yen, Chon-Ho; Yang, Tien-Shuh; Lin, Yin-Shen; Lee, Meng-Hwan; Yu, Kuo-Cheng; Huang, Chung-Lin; Hsieh, How-Hong; Tu, Ching-Fu

    2016-08-01

    Transgenic pigs failed to accord milk yield curve to lactate rhFIX-a vitamin K (VK) dependent protein even fed with VK enriched to 8 times higher than nutritional requirement. A further higher VK supplementation may be required. Homozygous transgenic sows (n = 4, 200 kg) at their 3rd nursing were divided into control and treatment groups and respectively received VK enriched and further menadione (soluble VK) supplemented diet (220 mg/kg VK enriched diet) for 33 days. At next lactation, control sows than received treatment and previous treated were fed on control diet. Results revealed that menadione treatment increased milk bioactivity of rhFIX from the 7th day of 73 to the 21st day of 153 IU/mL; it gradually decreased to 96 IU/mL on 35th day of lactation. Under control feeding, bioactivity remained relatively unchanged. However, milk rhFIX concentration and ratio of activated rhFIX responded little to the treatment. The menadione-induced bioactivity curve agrees with the known lactation pattern of sow means rhFIX secretion is still galactopoietic but requires high VK intake to show. The ineffectual VK spend on lactational carboxylation might be common in other mammary VK dependent expression system but can be effectively overcome by a high supplementation of menadione with a 5-folds improvement in quality.

  6. Is GPS telemetry location error screening beneficial?

    USGS Publications Warehouse

    Ironside, Kirsten E.; Mattson, David J.; Arundel, Terry; Hansen, Jered R.

    2017-01-01

    The accuracy of global positioning system (GPS) locations obtained from study animals tagged with GPS monitoring devices has been a concern as to the degree it influences assessments of movement patterns, space use, and resource selection estimates. Many methods have been proposed for screening data to retain the most accurate positions for analysis, based on dilution of precision (DOP) measures, and whether the position is a two dimensional or three dimensional fix. Here we further explore the utility of these measures, by testing a Telonics GEN3 GPS collar's positional accuracy across a wide range of environmental conditions. We found the relationship between location error and fix dimension and DOP metrics extremely weak (r2adj ∼ 0.01) in our study area. Environmental factors such as topographic exposure, canopy cover, and vegetation height explained more of the variance (r2adj = 15.08%). Our field testing covered sites where sky-view was so limited it affected GPS performance to the degree fix attempts failed frequently (fix success rates ranged 0.00–100.00% over 67 sites). Screening data using PDOP did not effectively reduce the location error in the remaining dataset. Removing two dimensional fixes reduced the mean location error by 10.95 meters, but also resulted in a 54.50% data reduction. Therefore screening data under the range of conditions sampled here would reduce information on animal movement with minor improvements in accuracy and potentially introduce bias towards more open terrain and vegetation.

  7. SU-E-T-130: Are Proton Gantries Needed? An Analysis of 4332 Patient Proton Gantry Treatment Plans From the Past 10 Years

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, S; Lu, H; Flanz, J

    2015-06-15

    Purpose: To ascertain the necessity of a proton gantry, as compared to the feasibility of using a horizontal fixed proton beam-line for treatment with advanced technology. Methods: To calculate the percentage of patients that can be treated with a horizontal fixed beam-line instead of a gantry, we analyze the distributions of beam orientations of our proton gantry patients treated over the past 10 years. We identify three horizontal fixed beam geometries (FIXED, BEND and MOVE) with the patient in lying and/or sitting positions. The FIXED geometry includes only table/chair rotations and translations. In BEND, the beam can be bent up/downmore » for up to 20 degrees. MOVE allows for patient head/body angle adjustment. Based on the analysis, we select eight patients whose plan involves beams which are still challenging to achieve with a horizontal fixed beam. These beams are removed in the pencil beam scanning (PBS) plan optimized for the fixed beam-line (PBS-fix). We generate non-coplanar PBS-gantry plans for comparison, and perform a robustness analysis. Results: The percentage of patients with head-and-neck/brain tumors that can be treated with horizontal fixed beam is 44% in FIXED, 70% in 20-degrees BEND, and 100% in 90-degrees MOVE. For torso regions, 99% of the patients can be treated in 20-degree BEND. The target coverage is more homogeneous with PBS-fix plans compared to the clinical scattering treatment plans. The PBS-fix plans reduce the mean dose to organs-at-risk by a factor of 1.1–28.5. PBS-gantry plans are as good as PBS-fix plans, sometimes marginally better. Conclusion: The majority of the beam orientations can be realized with a horizontal fixed beam-line. Challenging non-coplanar beams can be eliminated with PBS delivery. Clinical implementation of the proposed fixed beam-line requires use of robotic patient positioning, further developments in immobilization, and image guidance. However, our results suggest that fixed beam-lines can be as effective as gantries.« less

  8. Alternative allergy and the General Medical Council.

    PubMed Central

    Kay, A. B.

    1993-01-01

    In July 1992 Dr Keith Mumby, a clinical ecologist, appeared before the professional conduct committee of the General Medical Council on five charges to do with his practice of clinical ecology. He was found guilty of two of the charges--touting for publicity and failing to give a patient adequate medical attention--and admonished. The GMC failed, however, to address the issue of the nature of Mumby's treatments--clinical ecology itself. This is based on the idea that some patients are unusually susceptible to their environment, the diagnosis and treatment are based on an unstandardised provocation-neutralisation test. A variety of medical bodies have failed to find scientific foundation for the technique. The GMC's policy on advertising services to patients is inconsistent, and in this case it has shown a regrettable reluctance to deal with the issue of treatments that are not scientifically validated. Images p123-a PMID:8435610

  9. Retrospective cohort clinical investigation of a dental implant with a narrow diameter and short length for the partial rehabilitation of extremely atrophic jaws.

    PubMed

    Maló, Paulo S; de Araújo Nobre, Miguel A; Lopes, Armando V; Ferro, Ana S

    2017-01-01

    We investigated the short-term clinical outcomes of narrow-diameter short-length implants for the fixed-prosthetic partial rehabilitation of extremely resorbed jaws. Twenty-three patients requiring partial rehabilitations with narrow-platform short-length implants in any jaw were included in this study. In total, 30 implants 3.3 mm in diameter and 7 (n = 15 implants) or 8.5 (n = 15 implants) mm in length were inserted. The primary outcome measure was implant cumulative survival rate (CSR); the secondary outcome measures were marginal bone resorption at 1 and 3 years and the incidence of biologic and mechanical complications. Five patients (21.7%) with six implants (20%) were lost to follow-up. Two implants failed in two patients, yielding a CSR at 3 years of follow-up of 93.4%. The average (standard deviation) marginal bone resorption was 1.34 mm (0.95 mm) after the first year and 1.38 mm (0.78 mm) after the third year. Biologic complications occurred in three patients; mechanical complications occurred in three patients. Despite the limitations of the study, our findings show that the use of new narrow-diameter short-length implants for the rehabilitation of extremely atrophic regions is viable in the short-term, and can be considered a treatment alternative in extremely resorbed jaws.

  10. Clinical relevance of fixed ratio vs lower limit of normal of FEV1/FVC in COPD: patient-reported outcomes from the CanCOLD cohort.

    PubMed

    van Dijk, Wouter; Tan, Wan; Li, Pei; Guo, Best; Li, Summer; Benedetti, Andrea; Bourbeau, Jean

    2015-01-01

    The way in which spirometry is interpreted can lead to misdiagnosis of chronic obstructive pulmonary disease (COPD) resulting in inappropriate treatment. We compared the clinical relevance of 2 criteria for defining a low ratio of forced expiratory volume in 1 second to forced vital capacity (FEV1/FVC): the fixed ratio and the lower limit of normal. We analyzed data from the cross-sectional phase of the population-based Canadian Cohort of Obstructive Lung Disease (CanCOLD) study. We determined associations of the spirometric criteria for airflow limitation with patient-reported adverse outcomes, including respiratory symptoms, disability, health status, exacerbations, and cardiovascular disease. Sensitivity analyses were used to explore the impact of age and severity of airflow limitation on these associations. We analyzed data from 4,882 patients aged 40 years and older. The prevalence of airflow limitation was 17% by fixed ratio and 11% by lower limit of normal. Patients classified as having airflow limitation by fixed ratio only had generally small, nonsignificant increases in the odds of adverse outcomes. Patients having airflow limitation based on both fixed ratio and lower limit of normal had larger, significant increases in odds. But strongest associations were seen for patients who had airflow limitation by both fixed ratio and lower limit of normal and also had a low FEV1, defined as one less than 80% of the predicted value. Our results suggest that use of the fixed ratio alone may lead to misdiagnosis of COPD. A diagnosis established by both a low FEV1/FVC (according to fixed ratio and/or lower limit of normal) and a low FEV1 is strongly associated with clinical outcomes. Guidelines should be reconsidered to require both spirometry abnormalities so as to reduce overdiagnosis of COPD. © 2015 Annals of Family Medicine, Inc.

  11. Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients: Comparison of retainer failures and posttreatment stability. A 2-year follow-up of a single-center randomized controlled trial.

    PubMed

    Egli, Fabienne; Bovali, Efstathia; Kiliaridis, Stavros; Cornelis, Marie A

    2017-01-01

    The objectives of this 2-arm parallel trial were to compare the numbers of failures of mandibular fixed retainers bonded with indirect and direct methods and to investigate the posttreatment changes 2 years after placement. Sixty-four consecutive patients from the postgraduate orthodontic clinic of the University of Geneva in Switzerland were randomly allocated to either an indirect or a traditional direct bonding procedure of a mandibular fixed retainer at the end of their orthodontic treatment (T0). Eligibility criteria were the presence of the 4 mandibular incisors and the 2 mandibular canines, and no active caries, restorations, fractures, or periodontal disease of these teeth. The patients were randomized in blocks of 4 (using an online randomization service) with allocation concealment secured by contacting the sequence generator for assignment. The patients were recalled 12 months and 24 months (T3) after retainer bonding. The main outcome was any first-time failure of retainers (ie, at least 1 composite pad debonded or fractured); unexpected posttreatment changes of the mandibular incisors and canines were a secondary outcome. Impressions and lateral cephalograms were taken at T0 and T3: changes in mandibular intercanine and interpremolar distances and mandibular incisor inclination were assessed. Blinding was applicable for outcome assessment only. The chi-square test and Cox regression were used to compare the survival rates of the retainers bonded with direct and indirect methods. Paired t tests were used to assess differences in intercanine and interpremolar distances and mandibular incisor inclination at T0 and T3. Significance was set at P <0.05. Sixty-four patients were randomized in a 1:1 ratio. One patient dropped out at baseline, and 3 patients did not reach the T3 recall. In 24 of 60 (40%) patients, the fixed retainer failed within 2 years: 13 of 30 (43%) in the indirect bonding group and 11 of 30 (37%) in the direct bonding group (log-rank test, P = 0.64). The hazard ratio was 1.26 (95% confidence interval, 0.56-2.81; P = 0.58). Bond failures occurred mainly during the first year. There were no clinically significant changes in mandibular intercanine distance, interpremolar distance, and incisor inclination between T0 and T3, or between groups. In 5 patients (17%), all in the direct bonding group, unexpected posttreatment changes, systematically consisting in a lingual inclination of the mandibular left canine, were observed. In 1 patient (3%), the change was considered clinically severe. No other serious harm was observed. There was no difference in the risks of failure between mandibular retainers bonded with direct and indirect methods. Bonded retainers are effective in maintaining intercanine and interpremolar distances. There seem to be fewer unexpected posttreatment changes with retainers bonded with the indirect compared with the direct method. The trial was not registered. The protocol was not published before trial commencement. No funding or conflict of interest to be declared. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  12. Long-term clinical outcomes and survivorship of press-fit condylar sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients.

    PubMed

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik; Kulkarni, Sourabh S; Kim, Yoon-Hong

    2014-10-01

    We are aware of no study that has compared press-fit condylar Sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients after more than ten years of follow-up. The purpose of the current study was to compare these two implants with respect to the functional and radiographic results, prevalence of osteolysis, and overall revision rates at a mean of 12.1 years of follow-up. The study consisted of a consecutive series of 444 patients (mean age [and standard deviation], 66.5 ± 7.4 years) who underwent simultaneous bilateral total knee arthroplasty, with one side treated immediately after the other. All of the patients received a press-fit condylar Sigma mobile-bearing prosthesis on one side and a press-fit condylar Sigma fixed-bearing prosthesis on the contralateral side. The minimum duration of follow-up was ten years (mean, 12.1 years; range, ten to thirteen years). At the time of each follow-up visit, the patients were assessed clinically and radiographically. Postoperative total knee scores (95 and 94 points), Western Ontario and McMaster Universities Osteoarthritis Index (19 and 18 points), University of California, Los Angeles activity score (both prostheses, 5 points), range of motion (129° ± 6.3° and 127° ± 6.8°), and radiographic findings did not differ significantly between the press-fit condylar Sigma mobile and fixed-bearing designs at the final follow-up. The prevalence of aseptic loosening (1.4% and 1.8%) did not differ significantly between the mobile and fixed-bearing implant designs. No knee in either group had osteolysis. The estimated survival rate with revision as the end point was 98.2% (95% confidence interval, 91% to 99%) and 97.5% (95% confidence interval, 91% to 99%) at 12.1 years for the mobile and fixed-bearing implant groups, respectively. The results of the present long-term clinical study suggest that excellent clinical and radiographic results were achieved with both the press-fit condylar Sigma mobile and fixed-bearing cruciate-retaining total knee designs. We found no significant clinical advantage for a mobile-bearing over a fixed-bearing total knee prosthesis. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  13. Preadolescent's oral health-related quality of life during the first month of fixed orthodontic appliance therapy.

    PubMed

    Abreu, Lucas G; Lages, Elizabeth M B; Abreu, Mauro H N G; Pereira, Luciano J; Paiva, Saul M

    2013-09-01

    To evaluate preadolescent oral health related quality of life (OHRQoL) during the first month of fixed orthodontic appliance therapy. Descriptive study. The Department of Pediatric Dentistry and Orthodontics at Federal University of Minas Gerais, Belo Horizonte, Brazil. This study included a sample of 96 preadolescent children aged between 11 and 12 years undergoing orthodontic treatment with a fixed appliance. Preadolescent children were required to answer the short form of the Brazilian version of the Child Perceptions Questionnaire (CPQ11-14) before treatment (T0) and 1 month after placement of the fixed appliance (T1). Statistical analysis was performed using the Wilcoxon signed rank test and the Bonferroni correction for the domains of CPQ11-14. Out of the 96 patients originally admitted, one gave up the treatment before the placement of bands and one failed to return the second questionnaire (T1). So, a sample of 94 preadolescents participated in this study, with a response rate of 97·9%. Among the 94 participants, 49 were females (52·1 %) and 45 were males (47·9 %). The mean age was 11·5 years (SD = 0·502). There was a statistically significant improvement in emotional well-being domain (P<0·001) as well as in the overall score (P = 0·032). However, there were no significant changes in oral symptoms, functional limitations and social well-being domains (P>0·013) before treatment and 1 month after the placement of fixed appliance. One month after the placement of fixed orthodontic appliance, the preadolescents had positive alterations in their OHRQoL mainly in the emotional well-being domain.

  14. Two level pedicle substraction osteotomies for the treatment of severe fixed sagittal plane deformity: computer software-assisted preoperative planning and assessing.

    PubMed

    Atici, Yunus; Akman, Yunus Emre; Balioglu, Mehmet Bulent; Kargin, Deniz; Kaygusuz, Mehmet Akif

    2016-08-01

    To evaluate the efficacy of two level pedicle substraction osteotomies (PSOs) planned preoperatively with a computer software, in the patients with severe fixed sagittal plane deformities. In the literature, there are studies indicating that two level PSOs may be required in severe cases. However, the results of two level PSOs preoperatively planned with computer software-assistance have not yet been reported in the English literature. Severe fixed sagittal plane deformities of 11 patients are described. Preoperative surgical planning was done with the aid of a computer software. Two level PSOs were indicated after the process. After the application of the indicated surgical technique, clinical and radiological results were evaluated in the preoperative, the early postoperative periods and during the last follow-up. The mean sagittal vertical axis was found as 190.5 (range 161-220) mm in the preoperative period, 23.5 (range -27 to 61) mm in the early postoperative period (P < 0.001) (87.7 % correction) and 34.5 (range -3 to 55) mm during the last follow-up (P < 0.001). The mean pelvic tilt (PT) significantly decreased from 38.3° (range 21°-63°) preoperatively to 23.8° (range 18°-42°) postoperatively (P = 0.008) and to 27.5° (range 17°-42°) during the last follow-up (P = 0.042). The mean lumbar lordosis (LL) was 2.8° (range -29° to 20°) preoperatively, -35.6° (range -54° to 23°) early postoperatively (P < 0.001) and -33.6° (range -52° to 20°) during the last follow-up (P < 0.001). The average amount of bleeding was 5345 (range 2600-7415) ml. Although a statistically significant correction was obtained, the mean PT and PI-LL value could not be restored in physiological limits during the last follow-up. Thus, two level PSOs performed after computer software (surgimap) assisted preoperative planning failed to correct severe fixed sagittal plane deformities. Besides, this procedure is of possible risks for major complications such as a result of excessive bleeding. We recommend that two level PSOs should be rarely indicated, but preferred as an alternative technique only in the most severe cases.

  15. Customer-centered problem solving.

    PubMed

    Samelson, Q B

    1999-11-01

    If there is no single best way to attract new customers and retain current customers, there is surely an easy way to lose them: fail to solve the problems that arise in nearly every buyer-supplier relationship, or solve them in an unsatisfactory manner. Yet, all too frequently, companies do just that. Either we deny that a problem exists, we exert all our efforts to pin the blame elsewhere, or we "Band-Aid" the problem instead of fixing it, almost guaranteeing that we will face it again and again.

  16. Analyzing survival curves at a fixed point in time for paired and clustered right-censored data

    PubMed Central

    Su, Pei-Fang; Chi, Yunchan; Lee, Chun-Yi; Shyr, Yu; Liao, Yi-De

    2018-01-01

    In clinical trials, information about certain time points may be of interest in making decisions about treatment effectiveness. Rather than comparing entire survival curves, researchers can focus on the comparison at fixed time points that may have a clinical utility for patients. For two independent samples of right-censored data, Klein et al. (2007) compared survival probabilities at a fixed time point by studying a number of tests based on some transformations of the Kaplan-Meier estimators of the survival function. However, to compare the survival probabilities at a fixed time point for paired right-censored data or clustered right-censored data, their approach would need to be modified. In this paper, we extend the statistics to accommodate the possible within-paired correlation and within-clustered correlation, respectively. We use simulation studies to present comparative results. Finally, we illustrate the implementation of these methods using two real data sets. PMID:29456280

  17. Simultaneous mobile- and fixed-bearing total knee replacement in the same patients. A prospective comparison of mid-term outcomes using a similar design of prosthesis.

    PubMed

    Kim, Y-H; Kim, D-Y; Kim, J-S

    2007-07-01

    We conducted a randomised prospective study to evaluate the clinical and radiological results of a mobile- and fixed-bearing total knee replacement of similar design in 174 patients who had bilateral simultaneous knee replacement. The mean follow-up was for 5.6 years (5.2 to 6.1). The total knee score, pain score, functional score and range of movement were not statistically different (p > 0.05) between the two groups. Osteolysis was not seen in any knee in either group. Two knees (1%) in the mobile-bearing group required revision because of infection; none in the fixed-bearing group needed revision. Excellent results can be achieved with both mobile- and fixed-bearing prostheses of similar design at mid-term follow-up. We could demonstrate no significant clinical advantage for a mobile bearing.

  18. Commercial insurance vs community-based health plans: time for a policy option with clinical emphasis to address the cost spiral.

    PubMed

    Amundson, Bruce

    2005-01-01

    The nation continues its ceaseless struggle with the spiraling cost of health care. Previous efforts (regulation, competition, voluntary action) have included almost every strategy except clinical. Insurers have largely failed in their cost-containment efforts. There is a strong emerging body of literature that demonstrates the relationship between various clinical strategies and reductions in utilization and costs. This article describes the organization of health services, including integration of delivery and financing systems, at the community level as a model that effectively addresses the critical structural flaws that have frustrated control of costs. Community-based health plans (CHPs) have been developed and have demonstrated viability. The key elements of CHPs are a legal organizational structure, a full provider network, advanced care-management systems, and the ability to assume financial risk. Common misconceptions regarding obstacles to CHP development are the complexity of the undertaking, difficulty assuming the insurance function, and insured pools that are too small to be viable. The characteristics of successful CHPs and 2 case studies are described, including the types of advanced care-management systems that have resulted in strong financial performance. The demonstrated ability of CHPs to establish financial viability with small numbers of enrollees challenges the common assumption that there is a fixed relationship between health plan enrollment size and financial performance. Organizing the health system at the community/regional level provides an attractive alternative model in the health-reform debate. There is an opportunity for clinical systems and state and federal leaders to support the development of community-based integrated delivery and financing system models that, among other advantages, have significant potential to modulate the pernicious cost spiral.

  19. Clinical prospective evaluation of zirconia-based three-unit posterior fixed dental prostheses: Up-to ten-year results.

    PubMed

    Ioannidis, Alexis; Bindl, Andreas

    2016-04-01

    Only a few studies exist, which assess the clinical long-term behavior of all-ceramic FDPs in the posterior region. The aim of the present prospective clinical study was to evaluate the clinical performance of posterior three-unit FDPs manufactured from Y-TZP after a service period up to 10 years. 55 patients received 59 three-unit FDPs in the posterior region of the maxilla or mandible. Abutment teeth were prepared and full-arch impressions were taken. Definitive casts were fabricated and optically scanned. Frameworks were fabricated with computer-aided design (CAD) and manufacturing (CAM) technology. Y-TZP frameworks were veneered and adhesively luted to the abutment teeth. Baseline and follow-up examinations (service time: ≥ 48 months) were recorded by applying modified United States Public Health Services (USPHS) rating criteria. Cumulative survival rate was analyzed with Kaplan-Meier. Percentage of biological and technical complication was calculated. Fifty-three patients with 57 FDPs attended the last follow-up visit and a mean observation period of the remaining was 6.3 ± 1.9 years was calculated. Biological complications occurred in 17.5%, technical complications in 28% of the FDPs. The 10-year cumulative survival rate amounted 85.0%. Three FDPs failed to survive, two due to a root fracture of the abutment tooth and one due to secondary caries. Three-unit FDPs made from Y-TZP, veneered with ceramic offer a treatment option with a high rate of chipping. However, the manufacturing processes nowadays are modified in order to avoid this complication. The results of the present investigation suggest that three-unit Y-TZP posterior FDPs may are a possible treatment option. However, a high rate of chipping can be expected. Copyright © 2016. Published by Elsevier Ltd.

  20. EUS-guided methylene blue cholangiopancreatography for benign biliopancreatic diseases after failed ERCP.

    PubMed

    Consiglieri, Claudia F; Gornals, Joan B; Albines, Gino; De-la-Hera, Meritxell; Secanella, Lluis; Pelaez, Nuria; Busquets, Juli

    2016-07-01

    When ERCP fails, EUS-guided interventional techniques may be an alternative. The aim of this study was to evaluate the general outcomes and safety of EUS-guided methylene blue cholangiopancreatography in patients with failed ERCP in benign biliopancreatic diseases. Patients with benign biliopancreatic diseases and failed ERCP were included. EUS-guided cholangiopancreatography plus injection of methylene blue was performed, and then ERCP using coloring agent flow as an indicator of papilla orifice was performed. Procedures were prospectively collected in this observational, single-center study. Technical success, clinical success, and adverse events were analyzed retrospectively. Eleven patients were included (10 choledocholithiasis, 1 pancreatic stricture). The main reason for failed ERCP was an unidentifiable papilla. EUS-guided ductal access with cholangiopancreatography and papilla orifice identification was obtained in all cases. Technical success and clinical success rates of 91% were achieved, with successful biliopancreatic drainage in 10 patients. Adverse events included 1 peripancreatic abscess attributed to a precut, which was successfully treated. No adverse events were related to the first EUS-guided stage. EUS-guided cholangiopancreatography with methylene blue injection seems to be a feasible and helpful technique for treatment in patients with benign biliopancreatic diseases with previous failed ERCP because of an undetectable papilla. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  1. A break-even analysis of delivering a memory clinic by videoconferencing.

    PubMed

    Comans, Tracy A; Martin-Khan, Melinda; Gray, Leonard C; Scuffham, Paul A

    2013-10-01

    We analysed the costs of two kinds of dementia clinic. In the conventional clinic, held in a rural area, the specialist travels to the clinic from the city. In the videoconferencing clinic, patients are also seen in a rural area, but the specialist conducts the assessment by video from the city. The fixed costs common to both modalities, such as clinic infrastructure, were ignored. The total fixed cost of a monthly conventional clinic was $522 and the total fixed cost of a monthly videoconferencing clinic was $881. The additional variable cost of the specialist travelling to the conventional clinic was $2.62 per minute of the specialist's travelling time. The break-even point at which the cost of the two modalities is the same was just over two hours (138 min round trip). A sensitivity analysis showed that the break-even point was not particularly sensitive to changes in staff wages, but slightly more sensitive to the non labour costs of videoconferencing. Air travel is not an efficient alternative to travel by car. Reducing the number of clinics to six per year results in a much higher cost of running the videoconferencing service compared to the conventional service. Videoconferencing for the purpose of diagnosing dementia is both a reliable and cost effective method of health service provision when a specialist is required to drive for more than about two hours (round trip) to provide a memory disorder clinic service.

  2. Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy.

    PubMed

    Hernigou, Philippe; Huys, Maxime; Pariat, Jacques; Roubineau, François; Flouzat Lachaniette, Charles Henri; Dubory, Arnaud

    2018-02-01

    There is no information comparing the results of fixed-bearing total knee replacement and mobile-bearing total knee replacement in the same patients previously treated by high tibial osteotomy. The purpose was therefore to compare fixed-bearing and mobile-bearing total knee replacements in patients treated with previous high tibial osteotomy. We compared the results of 57 patients with osteoarthritis who had received a fixed-bearing prosthesis after high tibial osteotomy with the results of 41 matched patients who had received a rotating platform after high tibial osteotomy. The match was made for length of follow-up period. The mean follow-up was 17 years (range, 15-20 years). The patients were assessed clinically and radiographically. The pre-operative knee scores had no statistically significant differences between the two groups. So was the case with the intra-operative releases, blood loss, thromboembolic complications and infection rates in either group. There was significant improvement in both groups of knees, and no significant difference was observed between the groups (i.e., fixed-bearing and mobile-bearing knees) for the mean Knee Society knee clinical score (95 and 92 points, respectively), or the Knee Society knee functional score (82 and 83 points, respectively) at the latest follow-up. However, the mean post-operative knee motion was higher for the fixed-bearing group (117° versus 110°). In the fixed-bearing group, one knee was revised because of periprosthetic fracture. In the rotating platform mobile-bearing group, one knee was revised because of aseptic loosening of the tibial component. The Kaplan-Meier survivorship for revision at ten years of follow-up was 95.2% for the fixed bearing prosthesis and 91.1% for the rotating platform mobile-bearing prosthesis. Although we did manage to detect significant differences mainly in clinical and radiographic results between the two groups, we found no superiority or inferiority of the mobile-bearing total knee prosthesis over the fixed-bearing total knee prosthesis for patients previously operated by high tibial osteotomy.

  3. Long-term clinical and bacterial effects of xylitol on patients with fixed orthodontic appliances.

    PubMed

    Masoud, Mohamed I; Allarakia, Reem; Alamoudi, Najlaa M; Nalliah, Romesh; Allareddy, Veerasathpurush

    2015-01-01

    The objective of this study was to evaluate long-term clinical and bacterial effects of using 6 g of xylitol per day for 3 months on patients with full fixed orthodontic appliances. The study was a pilot clinical trial that included 41 subjects who were undergoing orthodontic treatment. The subjects were randomly divided into three groups. Group A received xylitol chewing gum, group B received xylitol dissolvable chewable tablets, and Group C served as the control group and did not receive xylitol gums or tablets. Clinical examination and the collection of plaque and saliva samples were carried out at baseline and 3, 6, and 12 months. All three groups were given oral hygiene instruction and were put on a 6-month cleaning and topical fluoride schedule. Plaque scores and bacterial counts were used to evaluate the effectiveness of the different approaches at reducing the caries risk. Xylitol groups did not experience any more reduction in plaque score, plaque MS counts, or salivary MS counts than the control group nor did they have lower values at any of the time points. Chewing gum did not significantly increase the incidence of debonded brackets over the other groups. Xylitol does not have a clinical or bacterial benefit in patients with fixed orthodontic appliances. Oral hygiene instructions and 6-month topical fluoride application were effective at reducing plaque scores and bacterial counts in patients with full fixed appliances regardless of whether or not xylitol was used.

  4. Hospital do-not-resuscitate orders: why they have failed and how to fix them.

    PubMed

    Yuen, Jacqueline K; Reid, M Carrington; Fetters, Michael D

    2011-07-01

    Do-not-resuscitate (DNR) orders have been in use in hospitals nationwide for over 20 years. Nonetheless, as currently implemented, they fail to adequately fulfill their two intended purposes--to support patient autonomy and to prevent non-beneficial interventions. These failures lead to serious consequences. Patients are deprived of the opportunity to make informed decisions regarding resuscitation, and CPR is performed on patients who would have wanted it withheld or are harmed by the procedure. This article highlights the persistent problems with today's use of inpatient DNR orders, i.e., DNR discussions do not occur frequently enough and occur too late in the course of patients' illnesses to allow their participation in resuscitation decisions. Furthermore, many physicians fail to provide adequate information to allow patients or surrogates to make informed decisions and inappropriately extrapolate DNR orders to limit other treatments. Because these failings are primarily due to systemic factors that result in deficient physician behaviors, we propose strategies to target these factors including changing the hospital culture, reforming hospital policies on DNR discussions, mandating provider communication skills training, and using financial incentives. These strategies could help overcome existing barriers to proper DNR discussions and align the use of DNR orders closer to their intended purposes of supporting patient self-determination and avoiding non-beneficial interventions at the end of life.

  5. Assessment and accountability: part 2 - managing failing students.

    PubMed

    Houghton, Trish

    2016-06-08

    Assessment in clinical practice is a complex role undertaken by mentors and practice teachers. This article is the second of three articles about assessment in practice. Part one examined the importance of assessment and identified various assessment methods used in clinical practice. This article considers two main themes in the assessment of practice. First, it outlines the importance of providing feedback, and explores preparation for regular feedback and the documentation used to help mentors and practice teachers undertake this activity. Second, it discusses management of failing students, and reviews the literature relating to the 'failure to fail' phenomenon. This article relates to the third domain and outcomes of the Nursing and Midwifery Council's Standards to Support Learning and Assessment in Practice on assessment and accountability.

  6. Should We Pursue Patients Who Fail to Attend Colorectal Clinics? A 9-Year Study

    PubMed Central

    John, SKP; Jones, OM; Fay, H; Howell, RD; Fozard, JBJ

    2007-01-01

    INTRODUCTION No uniform protocol exists on how to deal with patients who fail to attend colorectal clinics. Our aim was to identify whether the tendency to ‘failure to attend’ (FTA) in the colorectal clinic was associated with FTA in other clinics and also whether FTA patients have serious pathology. PATIENTS AND METHODS This was a retrospective study of a prospectively recorded list of FTA patients, in colorectal urgent or two-week wait clinics from 1996–2004. RESULTS A total of 151 patients, who failed to attend their first appointment, were included in the study. Of these, 61 (40.4%) were colorectal referrals, 76 (50.3%) were general surgical referrals, and for 14 (9.3%) case notes were not available. There were 59 FTA episodes in 61 colorectal patients associated with 59 FTA episodes in other clinics (Pearson correlation: r = 0.411; P = 0.01, two-tailed, SPSS v.12). Of 58 colorectal outcomes, five (8.6%) colorectal cancers (CRC) were diagnosed, 23 (39.6%) were persistent non-attendees, 16 (27.5%) had benign colorectal pathology, two (3.4%) benign non-colorectal outcomes and 12 (20.6%) normal outcomes. CONCLUSIONS Tendency to FTA is habitual. Care needs to be exercised in the management of FTAs to avoid delayed presentation of colorectal cancer. PMID:17688719

  7. Hot topic: Comparison of sex-sorted and conventional semen within a fixed-time artificial insemination protocol designed for dairy heifers.

    PubMed

    Mallory, D A; Lock, S L; Woods, D C; Poock, S E; Patterson, D J

    2013-02-01

    The objective was to compare pregnancy per AI (P/AI) with conventional (CON) or sex-sorted (SS) semen from a single sire within a fixed-time AI (FTAI) program designed for dairy heifers. Holstein heifers (n=240) were assigned to treatment (CON or SS) according to body weight and reproductive tract score. All heifers underwent FTAI by using the "Show-Me-Synch" protocol [controlled internal drug release (CIDR) insert from d 0 to 14 followed by PGF(2α) (25mg i.m.) 16d after insert removal (d 30) with GnRH (100 µg i.m.) and FTAI at 66 h after PGF(2α)]. A single professional technician performed the FTAI. Heifers were fitted with heat detection patches at PGF(2α) to characterize estrous response. Estrous response did not differ between CON (63/120; 53%) and SS (70/120; 58%) treatments. The CON heifers, however, achieved greater FTAI P/AI (82/120; 68%) compared with SS (45/120; 38%) heifers. The P/AI did not differ for CON heifers that exhibited or failed to exhibit estrus before FTAI [44/63 (70%) vs. 38/57(67%), respectively]. For SS heifers, however, those that exhibited estrus had greater P/AI compared with those that failed to exhibit estrus [32/70 (46%) vs. 13/50 (26%)]. Pregnancy per AI resulting from FTAI was greater for heifers that were inseminated with CON semen compared with those that received SS semen. The expression of estrus before FTAI did not affect P/AI when CON semen was used, whereas the P/AI with SS semen was greater for heifers detected in estrus. Further studies are required to develop strategies for using sex-sorted semen when inseminating heifers at predetermined fixed times on the basis of expression of estrus before FTAI. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Of magic wands and kaleidoscopes: fixing problems in the individual market.

    PubMed

    Hall, Mark A

    2002-01-01

    Policy analysts sometimes imagine that problems in the individual market can be fixed by waving a magic wand that makes the individual market function more like the group market. However, prior studies reveal that purchasing cooperatives fail to achieve substantial economies of scale; market reforms that reduce the impact of medical underwriting are difficult to implement in the individual market; and it may not be as easy as imagined to induce people to purchase over the Internet or from new or smaller companies that are at higher risk for exiting the market. The best solution is to limit the use of subsidies to certain purchasing options, such as with purchasing cooperatives that abide by rating, issuance, and renewability rules. What is not acceptable is to hand people subsidies and send them to the unstructured and relatively unregulated individual market, nor will it work to give people unhindered choice between two basically different market segments.

  9. Attrition in NRG Oncology's Radiation-Based Clinical Trials.

    PubMed

    Ulrich, Connie M; Deshmukh, Snehal; Pugh, Stephanie L; Hanlon, Alexandra; Grady, Christine; Watkins Bruner, Deborah; Curran, Walter

    2018-05-10

    To determine individual, organizational, and protocol-specific factors associated with attrition in NRG Oncology's radiation-based clinical trials. This retrospective analysis included 27,443 patients representing 134 NRG Oncology's radiation-based clinical trials .trials with primary efficacy results published from 1985-2011. Trials were separated on the basis of the primary endpoint (fixed time vs event driven). The cumulative incidence approach was used to estimate time to attrition, and cause-specific Cox proportional hazards models were used to assess factors associated with attrition. Most patients (69%) were enrolled in an event-driven trial (n = 18,809), while 31% were enrolled in a fixed-time trial (n = 8634). Median follow-up time for patients enrolled in fixed-time trials was 4.1 months and 37.2 months for patients enrolled in event-driven trials. Fixed time trials with a duration < 6 months had a 5 month attrition rate of 4.3% (95% confidence interval [CI]: 3.4%, 5.5%) and those with a duration ≥ 6 months had a 1 year attrition rate of 1.6% (95% CI: 1.2, 2.1). Event-driven trials had 1- and 5-year attrition rates of 0.5% (95% CI: 0.4%, 0.6%) and 13.6% (95% CI: 13.1%, 14.1%), respectively. Younger age, female gender, and Zubrod performance status >0 were associated with greater attrition as were enrollment by institutions in the West and South regions and participation in fixed-time trials. Attrition in clinical trials can have a negative effect on trial outcomes. Data on factors associated with attrition can help guide the development of strategies to enhance retention. These strategies should focus on patient characteristics associated with attrition in both fixed-time and event-driven trials as well as in differing geographic regions of the country. Copyright © 2018. Published by Elsevier Inc.

  10. The value of flexibility in conservation financing.

    PubMed

    Lennox, Gareth D; Fargione, Joseph; Spector, Sacha; Williams, Gwyn; Armsworth, Paul R

    2017-06-01

    Land-acquisition strategies employed by conservation organizations vary in their flexibility. Conservation-planning theory largely fails to reflect this by presenting models that are either extremely inflexible-parcel acquisitions are irreversible and budgets are fixed-or extremely flexible-previously acquired parcels can readily be sold. This latter approach, the selling of protected areas, is infeasible or problematic in many situations. We considered the value to conservation organizations of increasing the flexibility of their land-acquisition strategies through their approach to financing deals. Specifically, we modeled 2 acquisition-financing methods commonly used by conservation organizations: borrowing and budget carry-over. Using simulated data, we compared results from these models with those from an inflexible fixed-budget model and an extremely flexible selling model in which previous acquisitions could be sold to fund new acquisitions. We then examined 3 case studies of how conservation organizations use borrowing and budget carry-over in practice. Model comparisons showed that borrowing and budget carry-over always returned considerably higher rewards than the fixed-budget model. How they performed relative to the selling model depended on the relative conservation value of past acquisitions. Both the models and case studies showed that incorporating flexibility through borrowing or budget carry-over gives conservation organizations the ability to purchase parcels of higher conservation value than when budgets are fixed without the problems associated with the selling of protected areas. © 2016 Society for Conservation Biology.

  11. Commissioning of two RF operation modes for RF negative ion source experimental setup at HUST

    NASA Astrophysics Data System (ADS)

    Li, D.; Chen, D.; Liu, K.; Zhao, P.; Zuo, C.; Wang, X.; Wang, H.; Zhang, L.

    2017-08-01

    An RF-driven negative ion source experimental setup, without a cesium oven and an extraction system, has been built at Huazhong University of Science and Technology (HUST). The working gas is hydrogen, and the typical operational gas pressure is 0.3 Pa. The RF generator is capable of delivering up to 20 kW at 0.9 - 1.1 MHz, and has two operation modes, the fixed-frequency mode and auto-tuning mode. In the fixed-frequency mode, it outputs a steady RF forward power (Pf) at a fixed frequency. In the auto-tuning mode, it adjusts the operating frequency to seek and track the minimum standing wave ratio (SWR) during plasma discharge. To achieve fast frequency tuning, the RF signal source adopts a direct digital synthesizer (DDS). To withstand high SWR during the discharge, a tetrode amplifier is chosen as the final stage amplifier. The trend of maximum power reflection coefficient |ρ|2 at plasma ignition is presented at the fixed frequency of 1.02 MHz with the Pf increasing from 5 kW to 20 kW, which shows the maximum |ρ|2 tends to be "steady" under high RF power. The experiments in auto-tuning mode fail due to over-current protection of screen grid. The possible reason is the relatively large equivalent anode impedance caused by the frequency tuning. The corresponding analysis and possible solution are presented.

  12. Engineered Heart Repair.

    PubMed

    Fujita, B; Zimmermann, W-H

    2017-08-01

    There is a pressing need for the development of advanced heart failure therapeutics. Current state-of-the-art is protection from neurohumoral overstimulation, which fails to address the underlying cause of heart failure, namely loss of cardiomyocytes. Implantation of stem cell-derived cardiomyocytes via tissue-engineered myocardium is being advanced to realize the remuscularization of the failing heart. Here, we discuss pharmacological challenges pertaining to the clinical translation of tissue-engineered heart repair with a focus on engineered heart muscle (EHM). © 2017 American Society for Clinical Pharmacology and Therapeutics.

  13. Comparative field study: impact of laboratory assay variability on the assessment of recombinant factor IX Fc fusion protein (rFIXFc) activity.

    PubMed

    Sommer, Jurg M; Buyue, Yang; Bardan, Sara; Peters, Robert T; Jiang, Haiyan; Kamphaus, George D; Gray, Elaine; Pierce, Glenn F

    2014-11-01

    Due to variability in the one-stage clotting assay, the performance of new factor IX (FIX) products should be assessed in this assay. The objective of this field study was to evaluate the accuracy of measuring recombinant FIX Fc fusion protein (rFIXFc) activity in clinical haemostasis laboratories using the one-stage clotting assay. Human haemophilic donor plasma was spiked with rFIXFc or BeneFIX® at 0.80, 0.20, or 0.05 IU/ml based on label potency. Laboratories tested blinded samples using their routine one-stage assay and in-house FIX plasma standard. The mean spike recoveries for BeneFIX (n=30 laboratories) were 121 %, 144 %, and 168 % of expected at nominal 0.80, 0.20, and 0.05 IU/ml concentrations, respectively. Corresponding rFIXFc spike recoveries were 88 %, 107 %, and 132 % of expected, respectively. All BeneFIX concentrations were consistently overestimated by most laboratories. rFIXFc activity was reagent-dependent; ellagic acid and silica gave higher values than kaolin, which underestimated rFIXFc. BeneFIX demonstrated significantly reduced chromogenic assay activity relative to one-stage assay results and nominal activity, while rFIXFc activity was close to nominal activity at three concentrations with better dilution linearity than the typical one-stage assay. In conclusion, laboratory- and reagent-specific assay variabilities were revealed, with progressively higher variability at lower FIX concentrations. Non-parallelism against the FIX plasma standard was observed in all one-stage assays with rFIXFc and BeneFIX, leading to significant overestimation of FIX activity at lower levels and generally high inter-laboratory variability. Compared to the accuracy currently achieved in clinical laboratories when measuring other rFIX products, most laboratories measured rFIXFc activity with acceptable accuracy and reliability using routine one-stage assay methods and commercially available plasma standards.

  14. Fractographic analysis of anterior bilayered ceramic crowns that failed by veneer chipping.

    PubMed

    Du, Qian; Swain, Michael V; Zhao, Ke

    2014-05-01

    To fractographically analyze the reasons for the chipping of veneering porcelain in clinically failed anterior lithium disilicate glass-ceramic (LDG) and glass-infi ltrated alumina (GIA) crowns. Five anterior bilayered ceramic crowns with clinical veneer chipping failure were retrieved, of which three were LDG crowns and two were GIA crowns. The fractured surfaces of the failed restorations were examined using stereomicroscopy and scanning electron microscopy (SEM). The principles of fractography were used to identify the location and dimensions of the critical crack and to estimate the stress at failure. All five anterior crowns failed by cohesive failure within the veneer on the labial surface. Fractography showed that the critical crack initiated at the incisal contact area and propagated gingivally. The estimated stresses at failure for veneer chipping were lower than the characteristic strength of the veneer materials. Within the limitations of this in-vivo study, the contact damage, fatigue, and processing fl aws within the veneer are important reasons leading to chipping of veneering porcelain in anterior LDG and GIA crowns.

  15. The effect of load obliquity on the strength of locking and nonlocking constructs in synthetic osteoporotic bone.

    PubMed

    Tensmeyer, Daniel F; Gustafson, Peter A; Jastifer, James R; Patel, Bipin; Chess, Joseph L

    2015-11-01

    The biomechanical performance of internal fracture fixation depends on several factors. One measure of performance is the strength of the construct. The objective of this biomechanical study was to identify the effect of load obliquity on the strength of locking and nonlocking plate and screw constructs. For this study, plates and screws were fixed to synthetic osteoporotic bone that had a 1 mm thick synthetic cortical shell. An 8-hole, 3.5 mm thick hybrid plate was fixed with either two 3.5 mm major diameter locking screws or two 4.0 mm major diameter cancellous screws. Forces were applied at 0, 45, and 90 degrees to the plate normal. Eight specimens were loaded to failure for each group. When loads were applied normal to the plate, the nonlocking construct failed initially at higher loads (123.2 ± 13.2 N) than the locking construct (108.7 ± 7.6 N, P = 0.020). For oblique loads, the locking construct failed at higher mean loads but the difference of means was not statistically significant (167.7 ± 14.9 N compared to 154.2 ± 9.4 N, P = 0.052). For loads parallel to the plate, the locking construct was much stronger than the nonlocking construct (1591 ± 227 N compared to 913 ± 237 N, P < 0.001). Stiffness and Energy outcomes are also compared. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Uncemented glenoid component in total shoulder arthroplasty. Survivorship and outcomes.

    PubMed

    Martin, Scott David; Zurakowski, David; Thornhill, Thomas S

    2005-06-01

    Glenoid component loosening continues to be a major factor affecting the long-term survivorship of total shoulder replacements. Radiolucent lines, cement fracture, migration, and loosening requiring revision are common problems with cemented glenoid components. The purpose of this study was to evaluate the results of total shoulder arthroplasty with an uncemented glenoid component and to identify predictors of glenoid component failure. One hundred and forty-seven consecutive total shoulder arthroplasties were performed in 132 patients (mean age, 63.3 years) with use of an uncemented glenoid component fixed with screws between 1988 and 1996. One hundred and forty shoulders in 124 patients were available for follow-up at an average of 7.5 years. One shoulder in which the arthroplasty had failed at 2.4 years and for which the duration of follow-up was four years was also included for completeness. The preoperative diagnoses included osteoarthritis in seventy-two shoulders and rheumatoid arthritis in fifty-five. Radiolucency was noted around the glenoid component and/or screws in fifty-three of the 140 shoulders. The mean modified ASES (American Shoulder and Elbow Surgeons) score (and standard deviation) improved from 15.6 +/- 11.8 points preoperatively to 75.8 +/- 17.5 points at the time of follow-up. Eighty-five shoulders were not painful, forty-two were slightly or mildly painful, ten were moderately painful, and three were severely painful. Fifteen (11%) of the glenoid components failed clinically, and ten of them also had radiographic signs of failure. Eleven other shoulders had radiographic signs of failure but no symptoms at the time of writing. Three factors had a significant independent association with clinical failure: male gender (p = 0.02), pain (p < 0.01), and radiolucency adjacent to the flat tray (p < 0.001). In addition, the annual risk of implant revision was nearly seven times higher for patients with radiographic signs of failure. Clinical survivorship was 95% at five years and 85% at ten years. The failure rates of the total shoulder arthroplasties in this study were higher than those in previously reported studies of cemented polyethylene components with similar durations of follow-up. Screw breakage and excessive polyethylene wear were common problems that may lead to additional failures of these uncemented glenoid components in the future.

  17. Reducing motion artifacts for long-term clinical NIRS monitoring using collodion-fixed prism-based optical fibers.

    PubMed

    Yücel, Meryem A; Selb, Juliette; Boas, David A; Cash, Sydney S; Cooper, Robert J

    2014-01-15

    As the applications of near-infrared spectroscopy (NIRS) continue to broaden and long-term clinical monitoring becomes more common, minimizing signal artifacts due to patient movement becomes more pressing. This is particularly true in applications where clinically and physiologically interesting events are intrinsically linked to patient movement, as is the case in the study of epileptic seizures. In this study, we apply an approach common in the application of EEG electrodes to the application of specialized NIRS optical fibers. The method provides improved optode-scalp coupling through the use of miniaturized optical fiber tips fixed to the scalp using collodion, a clinical adhesive. We investigate and quantify the performance of this new method in minimizing motion artifacts in healthy subjects, and apply the technique to allow continuous NIRS monitoring throughout epileptic seizures in two epileptic in-patients. Using collodion-fixed fibers reduces the percent signal change of motion artifacts by 90% and increases the SNR by 6 and 3 fold at 690 and 830 nm wavelengths respectively when compared to a standard Velcro-based array of optical fibers. The SNR has also increased by 2 fold during rest conditions without motion with the new probe design because of better light coupling between the fiber and scalp. The change in both HbO and HbR during motion artifacts is found to be statistically lower for the collodion-fixed fiber probe. The collodion-fixed optical fiber approach has also allowed us to obtain good quality NIRS recording of three epileptic seizures in two patients despite excessive motion in each case. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Static network structure can stabilize human cooperation.

    PubMed

    Rand, David G; Nowak, Martin A; Fowler, James H; Christakis, Nicholas A

    2014-12-02

    The evolution of cooperation in network-structured populations has been a major focus of theoretical work in recent years. When players are embedded in fixed networks, cooperators are more likely to interact with, and benefit from, other cooperators. In theory, this clustering can foster cooperation on fixed networks under certain circumstances. Laboratory experiments with humans, however, have thus far found no evidence that fixed network structure actually promotes cooperation. Here, we provide such evidence and help to explain why others failed to find it. First, we show that static networks can lead to a stable high level of cooperation, outperforming well-mixed populations. We then systematically vary the benefit that cooperating provides to one's neighbors relative to the cost required to cooperate (b/c), as well as the average number of neighbors in the network (k). When b/c > k, we observe high and stable levels of cooperation. Conversely, when b/c ≤ k or players are randomly shuffled, cooperation decays. Our results are consistent with a quantitative evolutionary game theoretic prediction for when cooperation should succeed on networks and, for the first time to our knowledge, provide an experimental demonstration of the power of static network structure for stabilizing human cooperation.

  19. Static network structure can stabilize human cooperation

    PubMed Central

    Rand, David G.; Nowak, Martin A.; Fowler, James H.; Christakis, Nicholas A.

    2014-01-01

    The evolution of cooperation in network-structured populations has been a major focus of theoretical work in recent years. When players are embedded in fixed networks, cooperators are more likely to interact with, and benefit from, other cooperators. In theory, this clustering can foster cooperation on fixed networks under certain circumstances. Laboratory experiments with humans, however, have thus far found no evidence that fixed network structure actually promotes cooperation. Here, we provide such evidence and help to explain why others failed to find it. First, we show that static networks can lead to a stable high level of cooperation, outperforming well-mixed populations. We then systematically vary the benefit that cooperating provides to one’s neighbors relative to the cost required to cooperate (b/c), as well as the average number of neighbors in the network (k). When b/c > k, we observe high and stable levels of cooperation. Conversely, when b/c ≤ k or players are randomly shuffled, cooperation decays. Our results are consistent with a quantitative evolutionary game theoretic prediction for when cooperation should succeed on networks and, for the first time to our knowledge, provide an experimental demonstration of the power of static network structure for stabilizing human cooperation. PMID:25404308

  20. The Most Cut-Resistant Neck Guard for Preventing Lacerations to the Neck

    PubMed Central

    Loyd, Andre M.; Berglund, Lawrence; Twardowski, Casey P.; Stuart, Michael B.; Smith, Aynsley M.; Gaz, Daniel V.; Krause, David A.; An, Kai-Nan; Stuart, Michael J.

    2017-01-01

    Objective To evaluate the effectiveness of a variety of neck guard brands when contacted by a sharpened hockey skate blade. Design Analytic experimental. Setting Laboratory. Participants Neck surrogate. Interventions Forty-six samples of 14 different types of neck guards were tested on a custom-made laceration machine using a neck surrogate. Closed-cell polyethylene foam was placed between the neck surrogate and the protective device. Main Outcome Measures The effectiveness of the neck guard was evaluated by observation of the foam after the simulated slicing action of the skate blade. Two sets of tests were performed on each device sample including low and high force. For low-force tests, initial compression loads of 100, 200, and 300 N were applied between the neck surrogate for each of 2 orientations of the blade at 45 and 90 degrees. For high-force tests, representing a more severe simulation, the applied load was increased to 600 N and a blade angle fixed at 45 degrees. All tests were performed at a blade speed of 5 m/s. Results Only 1 product, the Bauer N7 Nectech, failed during the 300-N compression tests. All of the neck guards failed during 600-N test condition except for the Skate Armor device and 1 of the 3 Reebok 11K devices. Conclusions A skate blade angle of 45 degrees increased the likelihood of a neck laceration compared with a skate blade angle of 90 degrees due to decreased contact area. Damage to the neck guard is not an indicator of the cut resistance of a neck guard. Neck protectors with Spectra fibers were the most cut resistant. Clinical Relevance The study provides data for the selection of neck guards and neck guard materials that can reduce lacerations to the neck. PMID:24949830

  1. Randomized, Controlled Trial of Therapy Interruption in Chronic HIV-1 Infection

    PubMed Central

    Papasavvas, Emmanouil; Kostman, Jay R; Mounzer, Karam; Grant, Robert M; Gross, Robert; Gallo, Cele; Azzoni, Livio; Foulkes, Andrea; Thiel, Brian; Pistilli, Maxwell; Mackiewicz, Agnieszka; Shull, Jane; Montaner, Luis J

    2004-01-01

    Background Approaches to limiting exposure to antiretroviral therapy (ART) drugs are an active area of HIV therapy research. Here we present longitudinal follow-up of a randomized, open-label, single-center study of the immune, viral, and safety outcomes of structured therapy interruptions (TIs) in patients with chronically suppressed HIV-1 infection as compared to equal follow-up of patients on continuous therapy and including a final therapy interruption in both arms. Methods and Findings Forty-two chronically HIV-infected patients on suppressive ART with CD4 counts higher than 400 were randomized 1:1 to either (1) three successive fixed TIs of 2, 4, and 6 wk, with intervening resumption of therapy with resuppression for 4 wk before subsequent interruption, or (2) 40 wk of continuous therapy, with a final open-ended TI in both treatment groups. Main outcome was analysis of the time to viral rebound (>5,000 copies/ml) during the open-ended TI. Secondary outcomes included study-defined safety criteria, viral resistance, therapy failure, and retention of immune reconstitution. There was no difference between the groups in time to viral rebound during the open-ended TI (continuous therapy/single TI, median [interquartile range] = 4 [1–8] wk, n = 21; repeated TI, median [interquartile range] = 5 [4–8] wk, n = 21; p = 0.36). No differences in study-related adverse events, viral set point at 12 or 20 wk of open-ended interruption, viral resistance or therapy failure, retention of CD4 T cell numbers on ART, or retention of lymphoproliferative recall antigen responses were noted between groups. Importantly, resistance detected shortly after initial viremia following the open-ended TI did not result in a lack of resuppression to less than 50 copies/ml after reinitiation of the same drug regimen. Conclusion Cycles of 2- to 6-wk time-fixed TIs in patients with suppressed HIV infection failed to confer a clinically significant benefit with regard to viral suppression off ART. Also, secondary analysis showed no difference between the two strategies in terms of safety, retention of immune reconstitution, and clinical therapy failure. Based on these findings, we suggest that further clinical research on the long-term consequences of TI strategies to decrease drug exposure is warranted. PMID:15630469

  2. Early experience with formalin-fixed paraffin-embedded (FFPE) based commercial clinical genomic profiling of gliomas-robust and informative with caveats.

    PubMed

    Movassaghi, Masoud; Shabihkhani, Maryam; Hojat, Seyed A; Williams, Ryan R; Chung, Lawrance K; Im, Kyuseok; Lucey, Gregory M; Wei, Bowen; Mareninov, Sergey; Wang, Michael W; Ng, Denise W; Tashjian, Randy S; Magaki, Shino; Perez-Rosendahl, Mari; Yang, Isaac; Khanlou, Negar; Vinters, Harry V; Liau, Linda M; Nghiemphu, Phioanh L; Lai, Albert; Cloughesy, Timothy F; Yong, William H

    2017-08-01

    Commercial targeted genomic profiling with next generation sequencing using formalin-fixed paraffin embedded (FFPE) tissue has recently entered into clinical use for diagnosis and for the guiding of therapy. However, there is limited independent data regarding the accuracy or robustness of commercial genomic profiling in gliomas. As part of patient care, FFPE samples of gliomas from 71 patients were submitted for targeted genomic profiling to one commonly used commercial vendor, Foundation Medicine. Genomic alterations were determined for the following grades or groups of gliomas; Grade I/II, Grade III, primary glioblastomas (GBMs), recurrent primary GBMs, and secondary GBMs. In addition, FFPE samples from the same patients were independently assessed with conventional methods such as immunohistochemistry (IHC), Quantitative real-time PCR (qRT-PCR), or Fluorescence in situ hybridization (FISH) for three genetic alterations: IDH1 mutations, EGFR amplification, and EGFRvIII expression. A total of 100 altered genes were detected by the aforementioned targeted genomic profiling assay. The number of different genomic alterations was significantly different between the five groups of gliomas and consistent with the literature. CDKN2A/B, TP53, and TERT were the most common genomic alterations seen in primary GBMs, whereas IDH1, TP53, and PIK3CA were the most common in secondary GBMs. Targeted genomic profiling demonstrated 92.3%-100% concordance with conventional methods. The targeted genomic profiling report provided an average of 5.5 drugs, and listed an average of 8.4 clinical trials for the 71 glioma patients studied but only a third of the trials were appropriate for glioma patients. In this limited comparison study, this commercial next generation sequencing based-targeted genomic profiling showed a high concordance rate with conventional methods for the 3 genetic alterations and identified mutations expected for the type of glioma. While it may not be feasible to exhaustively independently validate a commercial genomic profiling assay, examination of a few markers provides some reassurance of its robustness. While potential targeted drugs are recommended based on genetic alterations, to date most targeted therapies have failed in glioblasomas so the usefulness of such recommendations will increase with development of novel and efficacious drugs. Copyright © 2017. Published by Elsevier Inc.

  3. Fracture strength of artificially aged 3-unit adhesive fixed partial dentures made of fiber-reinforced composites and ceramics: an in vitro study.

    PubMed

    Kolbeck, Carola; Rosentritt, Martin; Handel, Gerhard

    2006-10-01

    The aim of this in vitro study was to examine the fracture strength of metal-free 3-unit adhesive fixed partial dentures (AFPDs) bonded to mandibular incisors. Extracted human incisors were positioned in pairs in polymethyl methacrylate resin simulating a clinical anterior situation. Their lingual sides were prepared for adhesive retainers with surfaces and finishing lines in enamel. Eight 3-unit AFPDs were made on master casts per material system: Connect/belleGlass (Girrbach), StickNet (StickTech)/Sinfony (3M Espe), and Empress 2 (Ivoclar Vivadent). The dentures were bonded adhesively using the dual-curing system ED Primer/ Panavia F (Kuraray Europe) and aged by thermocycling (6,000 x 5 degrees C/55 degrees C H2O; 2 minutes each cycle) and mechanical loading (1.2 x 10(6) x 20 N with 1.66 Hz) in an artificial oral environment representing a wearing period of 5 years. The fracture strength was determined in a universal testing machine (UTM 1446, Zwick) at a speed of 1 mm/min, applying the load buccoincisally on the pontics. The different forms of failure were described optically. Medians (25th/75th percentiles) of the fracture results were calculated. Statistical analysis was performed using Mann-Whitney U and Kruskal-Wallis tests (P < or = .05). Five StickNet/Sinfony AFPDs and 7 Empress 2 restorations failed in the artificial oral environment. The remaining Empress 2 dentures showed the highest medians of fracture forces (339 [200/506] N) compared to Connect/belleGlass (257 [242/310] N) and StickNet/Sinfony (256 [204/347] N). Statistical comparisons showed no significant differences. Only Connect/belleGlass and Empress 2 showed sufficient resistance against mastication

  4. Circadian phase-shifting effects of a laboratory environment: a clinical trial with bright and dim light.

    PubMed

    Youngstedt, Shawn D; Kripke, Daniel F; Elliott, Jeffrey A; Rex, Katharine M

    2005-09-09

    Our aims were to examine the influence of different bright light schedules on mood, sleep, and circadian organization in older adults (n = 60, ages 60-79 years) with insomnia and/or depression, contrasting with responses of young, healthy controls (n = 30, ages 20-40 years). Volunteers were assessed for one week in their home environments. Urine was collected over two 24-hour periods to establish baseline acrophase of 6-sulphatoxymelatonin (aMT6s) excretion. Immediately following home recording, volunteers spent five nights and four days in the laboratory. Sleep periods were fixed at eight hours in darkness, consistent with the volunteers' usual sleep periods. Volunteers were randomly assigned to one of three light treatments (four hours per day) within the wake period: (A) two hours of 3,000 lux at 1-3 hours and 13-15 hours after arising; (B) four hours of 3,000 lux at 6-10 hours after arising; (C) four hours of dim placebo light at 6-10 hours after arising. Lighting was 50 lux during the remainder of wakefulness. The resulting aMT6s acrophase was determined during the final 30 hours in the laboratory. Neither mood nor total melatonin excretion differed significantly by treatment. For the three light treatments, significant and similar phase-response plots were found, indicating that the shift in aMT6s acrophase was dependent upon the circadian time of treatment. The changes in circadian timing were not significantly correlated to changes in sleep or mood. The trial failed to demonstrate photoperiodic effects. The results suggest that even low levels of illumination and/or fixed timing of behavior had significant phase-shifting effects.

  5. Monolithic and bi-layer CAD/CAM lithium-disilicate versus metal-ceramic fixed dental prostheses: comparison of fracture loads and failure modes after fatigue.

    PubMed

    Schultheis, Stefan; Strub, Joerg R; Gerds, Thomas A; Guess, Petra C

    2013-06-01

    The authors analyzed the effect of fatigue on the survival rate and fracture load of monolithic and bi-layer CAD/CAM lithium-disilicate posterior three-unit fixed dental prostheses (FDPs) in comparison to the metal-ceramic gold standard. The authors divided 96 human premolars and molars into three equal groups. Lithium-disilicate ceramic (IPS-e.max-CAD) was milled with the CEREC-3-system in full-anatomic FDP dimensions (monolithic: M-LiCAD) or as framework (Bi-layer: BL-LiCAD) with subsequent hand-layer veneering. Metal-ceramic FDPs (MC) served as control. Single-load-to-failure tests were performed before and after mouth-motion fatigue. No fracture failures occurred during fatigue. Median fracture loads in [N], before and after fatigue were, respectively, as follows: M-LiCAD, 1,298/1,900; BL-LiCAD, 817/699; MC, 1,966/1,818. M-LiCAD and MC FPDs revealed comparable fracture loads and were both significantly higher than BL-LiCAD. M-LiCAD and BL-LiCAD both failed from core/veneer bulk fracture within the connector area. MC failures were limited to ceramic veneer fractures exposing the metal core. Fatigue had no significant effect on any group. Posterior monolithic CAD/CAM fabricated lithium-disilicate FPDs were shown to be fracture resistant with failure load results comparable to the metal-ceramic gold standard. Clinical investigations are needed to confirm these promising laboratory results. Monolithic CAD/CAM fabricated lithium-disilicate FDPs appeared to be a reliable treatment alternative for the posterior load-bearing area, whereas FDPs in bi-layer configuration were susceptible to low load fracture failure.

  6. Summary of the British Transplantation Society Guidelines for Management of the Failing Kidney Transplant.

    PubMed

    Andrews, Peter A

    2014-12-15

    The British Transplantation Society "Guideline for Transplantation Management of the Failing Kidney Transplant" was published in May 2014. This is the first national guideline in this field. In line with previous guidelines published by the British Transplantation Society, the guideline has used the GRADE system to rate the strength of evidence and recommendations.This article summarizes the Statements of Recommendation contained in the guideline, which provide a framework for the management of the failing kidney graft in the United Kingdom and may be of wide international interest. It is recommended that the full guideline document is consulted for details of the relevant references and evidence base. This may be accessed at: http://www.bts.org.uk/MBR/Clinical/Guidelines/Current/Member/Clinical/Current_Guidelines.aspx.

  7. Conservative management of cesarean scar pregnancies: a prospective randomized controlled trial at a single center.

    PubMed

    Wang, Mingyi; Yang, Zhiling; Li, Yunming; Chen, Biliang; Wang, Jian; Ma, Xiangdong; Wang, Yu

    2015-01-01

    To assess clinical outcomes related to conservative management of women with cesarean scar pregnancies (CSPs), specifically through uterine artery embolization (UAE) with local and systemic methotrexate (MTX) treatment (UAE-MTX), or ultrasound-guided local and systemic MTX treatment (USG-MTX). Forty-five patients with CSP were randomly allocated to receive UAE-MTX (n = 24) or USG-MTX (n = 21). Participants' clinical outcomes were compared, and clinical characteristics of failed cases were evaluated relative to successful cases. The 2 groups were similar in clinical characteristics, success rate (83.3% cf. 80.9%), time to normalization of serum beta (β) human chorionic gonadotropin (β-hCG), and percentage of patients receiving multiple doses of systemic MTX. However, within the failed cases, the percentages of patients with gestational sac > 5 cm (87.5%), or type II CSP (75.0%) was significantly higher than in the successful cases (13.5% and 18.9%, respectively; P < 0.001, both), without regard to treatment group. According to the logistic regression model, a gestational sac diameter > 5 cm or type II CSP were independent risk factors for failed CSP management (gestational sac > 5 cm: OR 51.87, 95% CI 3.48-775.91, P < 0.01; type II CSP: OR 15.54, 95% CI 1.25-193.36, P < 0.05). The conservative treatments UAE-MTX and USG-MTX were similarly effective in treating CSP patients. Either treatment was likely to fail for CSP patients with gestational sac > 5 cm or type II CSP.

  8. Higher forgotten joint score for fixed-bearing than for mobile-bearing total knee arthroplasty.

    PubMed

    Thienpont, E; Zorman, D

    2016-08-01

    To compare the postoperative subjective outcome for fixed- and mobile-bearing total knee arthroplasty (TKA) by using the forgotten joint score (FJS-12), a new patient-reported outcome score of 12 questions evaluating the potential of a patient to forget about his operated joint. The hypothesis of this study was that a mobile-bearing TKA would have a higher level of forgotten joint than a fixed-bearing model of the same design. A retrospective cohort study was conducted in 100 patients who underwent TKA at least 1 year [mean (SD) 18 (5) months] before with either a fixed-bearing (N = 50) or a mobile-bearing (N = 50) TKA from the same implant family. Clinical outcome was evaluated with the knee society score and patient-reported outcome with the forgotten joint score. No difference was observed for demographics in between both study groups. The mean (SD) postoperative FJS-12 for the fixed-bearing TKA was 71 (28) compared to a mean (SD) of 56.5 (30) for the mobile-bearing TKA. The clinical relevance of the present retrospective study is that it shows for the first time a significant difference between fixed- and mobile-bearing TKA by using a new patient-reported outcome score. The hypothesis that mobile-bearing TKA would have a higher degree of forgotten joint than a fixed-bearing TKA could not be confirmed. A level I prospective study should be set up to objectivise these findings. IV.

  9. Existence of Normal Limbal Epithelium in Eyes with Clinical Signs of Total Limbal Stem Cell Deficiency

    PubMed Central

    Codriansky, Andres; Hong, Jiaxu; Xu, Jianjian; Deng, Sophie X.

    2016-01-01

    Purpose To report the presence of normal limbal epithelium detected by in vivo confocal laser scanning microscopy (IVCM) in three cases of clinically diagnosed total limbal stem cell deficiency (LSCD). Methods This is a retrospective case report consists of three patients who were diagnosed with total LSCD based on clinical exam and/or impression cytology. Clinical data including ocular history, presentation, slit-lamp examination, IVCM and impression cytology were reviewed. Results The etiology was chemical burn in three cases. One patient has two failed penetrating keratoplasty. Another had allogeneic keratolimbal transplantation but the graft failed one year after surgery. The third patient had failed amniotic membrane transplantation. These three patients presented with signs of total LSCD including the absence of normal Vogt palisades, complete superficial vascularization of the peripheral cornea, non-healing epithelial defects, and corneal scarring. Impression cytology was performed in two cases to confirm the presence of goblet cells in two cases. Each patient however still had distinct areas of corneal and/or limbal epithelial cells detected by IVCM. Conclusions Residual normal limbal epithelial cells could be present in eyes with clinical features of total LSCD. IVCM appears to be a more accurate method to evaluate the degree of LSCD. PMID:27362882

  10. Undetectable Transcription of cap in a Clinical AAV Vector: Implications for Preformed Capsid in Immune Responses

    PubMed Central

    Hauck, Bernd; Murphy, Samuel L; Smith, Peter H; Qu, Guang; Liu, Xingge; Zelenaia, Olga; Mingozzi, Federico; Sommer, Jürg M; High, Katherine A; Wright, J. Fraser

    2008-01-01

    In a gene therapy clinical trial for hemophilia B, adeno-associated virus 2 (AAV2) capsid–specific CD8+ T cells were previously implicated in the elimination of vector-transduced hepatocytes, resulting in loss of human factor IX (hFIX) transgene expression. To test the hypothesis that expression of AAV2 cap DNA impurities in the AAV2-hFIX vector was the source of epitopes presented on transduced cells, transcription of cap was assessed by quantitative reverse transcription–PCR (Q-RT-PCR) following transduction of target cells with the vector used in the clinical trial. Transcriptional profiling was also performed for residual AmpR, and adenovirus E2A and E4. Although trace amounts of DNA impurities were present in the clinical vector, transcription of these sequences was not detected after transduction of human hepatocytes, nor in mice administered a dose 26-fold above the highest dose administered in the clinical study. Two methods used to minimize encapsidated DNA impurities in the clinical vector were: (i) a vector (cis) production plasmid with a backbone exceeding the packaging limit of AAV; and (ii) a vector purification step that achieved separation of the vector from vector-related impurities (e.g., empty capsids). In conclusion, residual cap expression was undetectable following transduction with AAV2-hFIX clinical vectors. Preformed capsid protein is implicated as the source of epitopes recognized by CD8+ T cells that eliminated vector-transduced cells in the clinical study. PMID:18941440

  11. Rehabilitation with implant-supported overdentures in total edentulous patients: A review.

    PubMed

    Martínez-Lage-Azorín, Juan F; Segura-Andrés, Gustavo; Faus-López, Joan; Agustín-Panadero, Rubén

    2013-12-01

    The main aim of this review article is to discuss implant-supported overdentures (ISOs) as treatment in edentulous patients. Besides, we will try to discuss among the different treatment options in such patients and to analyze their validity when ISOs are compared with other clinical modalities. At the same time, we will try to suggest clinical guidelines supported by current clinical studies. We performed a Medline search and review of pertinent articles on the mentioned subject from 1986 to 2011. As a searching strategy, we used the following words: implant-supported overdentures, attachment systems, Locator attachment, cantilever, fixed prosthesis. Implant-supported overdentures constitute an accurate and predictable treatment option and achieve a higher patients' satisfaction. This type of treatment constitutes a cheaper treatment than fixed prostheses and in some patients, with loss of lip support or with an interoclusal space larger than 15 mm, the choice of implant-supported overdentures seems to prevent future aesthetic or phonetic problems. Key words:Overdentures, implant occlusion, implant rehabilitation, total edentulous rehabilitation, fixed prosthesis.

  12. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    PubMed

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. The financial and service implications of splitting fixed-dose antiretroviral drugs - a case study.

    PubMed

    Taylor, R; Carlin, E; Sadique, Z; Ahmed, I; Adams, E J

    2015-02-01

    In 2010/2011, regional commissioners withdrew payment for the fixed-dose combination Combivir, forcing a switch to component drugs. This was deemed clinically acceptable and annual savings of £44 k expected. We estimated the true costs of switching and examined patient outcomes. Information for 46 patients using Combivir was extracted from case notes for each clinical contact in the 12 months pre- and post-switch (clinician seen, tests, antiretrovirals). Post-switch care costs £93/patient more annually versus pre-switch (95% CI £424 to £609), yielding £4278/year more post-switch for all patients. Drug and pathology costs were more expensive post-switch and extra clinical visits required. None of these results were statistically significant. Forty-two per cent of patients switched directly or in the subsequent year to an alternative fixed-dose combination rather than generics. Costs in this group were significantly higher post-switch driven by drug cost. Six patients (13%) reported problems with the switch including confusion around dosing and new side effects. As less-expensive generic antiretroviral drugs become available, it may appear cheaper to switch from fixed-dose combinations to component drugs. However, the additional clinical costs involved may outweigh the initial cost savings of the drugs and switching may cause confusion for some patients, risking loss of adherence. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. A review of clinical and technical considerations for fixed and removable implant prostheses in the edentulous mandible.

    PubMed

    Zitzmann, Nicola Ursula; Marinello, Carlo Paolo

    2002-01-01

    The aim of the present article is to review some of the technical treatment options for implant prostheses restoring the edentulous mandible, mainly based on the Brånemark system. Clinical and technical aspects are discussed for the three established concepts: (1) implant-supported fixed prosthesis, (2) removable implant-supported overdenture, and (3) combined implant-retained and soft tissue-supported overdenture prosthesis. The framework of an implant-supported fixed screw-retained prosthesis can be processed in gold, Co-Cr alloy, or titanium with casting, laser-welding, or milling techniques. To improve the stability and retention of a conventional complete denture, one to four implants are indicated, and unsplinted (single attachments) or splinted designs (bar systems) can be applied. The design of the overdenture prosthesis must be carefully planned according to the requirements to ensure adequate stability and optimal form, contour, and esthetics, and the patient's best comfort. A large variety of different treatment modalities exist for both the fixed and removable mandibular implant prosthesis. Clinical and technical aspects should be considered at the beginning of the treatment to: (1) select the optimal implant position, (2) establish an adequate number of functional units, (3) select the appropriate retainers, and (4) apply the best technique for framework processing and veneering.

  15. [Comparison of the treatment of slipped capital femoral epiphysis with K-wires and cannulated titanium screws].

    PubMed

    Maus, U; Ihme, N; Niedhart, C; Abeler, E; Kochs, A; Gravius, S; Ohnsorge, J A K; Andereya, S

    2008-01-01

    The treatment of slipped capital femoral epiphysis (SCFE) is usually treated operatively, but there is still no consensus about the method to be used. Up to a 30 degrees degree of slipping, the epiphysis is normally fixed in situ. The aim of our study was to compare the intermediate results after fixation in situ by K-wires versus cannulated titanium screws (Königsee-Implantate, Königsee-Aschau, Germany). In this study 46 patients with SCFE grade I and II and mostly chronic slipping of the epiphysis were included. After fixation in situ and, if necessary, careful, closed reposition, the patients were clinically and radiologically followed-up for one year. The clinical results were documented by the score adapted from Heyman and Herndon. Furthermore, MRI scans were done to evaluate the vitality of the epiphysis pre- and postoperatively, when titanium screws were used. Clinical follow-up showed comparable results in the clinical scores after fixation by K-wires or cannulated titanium screws (3.13 +/- 1.02 vs. 3.10 +/- 1.01). After the treatment with titanium screws we saw a higher rate of abnormal gait (33.3 % vs. 19 %), a decreased rate of the positive Drehmann sign (10 % vs. 38 %) and a lower rate of revisions (16 % vs. 50 %) in comparison to K-wire fixation. After displacement of the K-wires we saw chondrolysis and prearthrosis in one case. Removal of the K-wires was done without any complications, while the removal of the cannulated titanium screws failed in 4 of 10 cases. The treatment of SCFE with K-wires and cannulated titanium screws showed comparable results in the clinical follow-up. The treatment with cannulated titanium screws reduces the number of necessary revisions, but the removal of the material is hindered. Because of the lower rate of complications we prefer in the meantime the use of cannulated steel screws.

  16. Treating childhood pneumonia in hard-to-reach areas: a model-based comparison of mobile clinics and community-based care.

    PubMed

    Pitt, Catherine; Roberts, Bayard; Checchi, Francesco

    2012-01-10

    Where hard-to-access populations (such as those living in insecure areas) lack access to basic health services, relief agencies, donors, and ministries of health face a dilemma in selecting the most effective intervention strategy. This paper uses a decision mathematical model to estimate the relative effectiveness of two alternative strategies, mobile clinics and fixed community-based health services, for antibiotic treatment of childhood pneumonia, the world's leading cause of child mortality. A "Markov cycle tree" cohort model was developed in Excel with Visual Basic to compare the number of deaths from pneumonia in children aged 1 to 59 months expected under three scenarios: 1) No curative services available, 2) Curative services provided by a highly-skilled but intermittent mobile clinic, and 3) Curative services provided by a low-skilled community health post. Parameter values were informed by literature and expert interviews. Probabilistic sensitivity analyses were conducted for several plausible scenarios. We estimated median pneumonia-specific under-5 mortality rates of 0.51 (95% credible interval: 0.49 to 0.541) deaths per 10,000 child-days without treatment, 0.45 (95% CI: 0.43 to 0.48) with weekly mobile clinics, and 0.31 (95% CI: 0.29 to 0.32) with CHWs in fixed health posts. Sensitivity analyses found the fixed strategy superior, except when mobile clinics visited communities daily, where rates of care-seeking were substantially higher at mobile clinics than fixed posts, or where several variables simultaneously differed substantially from our baseline assumptions. Current evidence does not support the hypothesis that mobile clinics are more effective than CHWs. A CHW strategy therefore warrants consideration in high-mortality, hard-to-access areas. Uncertainty remains, and parameter values may vary across contexts, but the model allows preliminary findings to be updated as new or context-specific evidence becomes available. Decision analytic modelling can guide needed field-based research efforts in hard-to-access areas and offer evidence-based insights for decision-makers.

  17. A house officer-sponsored quality improvement initiative: leadership lessons and liabilities.

    PubMed

    Weingart, S N

    1998-07-01

    House officers play an important role in the care of hospitalized patients, yet they are infrequent participants in quality improvement (QI) activities. A grassroots QI initiative among medical house officers was implemented at Beth Israel Deaconess Medical Center's East Campus in Boston from 1995 through 1997. A group of house officer volunteers completed five of nine projects, including a survey that demonstrated frequent failures of cardiac monitor-defibrillators in the emergency room. Reaching out to key administrators produced several quick fixes. Developing effective, ongoing partnerships with clinical departments and QI professionals proved more problematic. Residency training programs that provide experience in QI give house officers a potentially valuable skill and an additional means to improve the quality of patient care. Yet many obstacles work against house officers' participation in QI initiatives, including long hours and the daily demands of patient care, rotating monthly assignments, and clinical leaders' assumption that they have little interest in QI. The organizers of the officer problem-solving group over-estimated the hospital resources at their disposal and failed to build mechanisms to ensure the initiative's continuation into its second year, when their own interest waned and no new group of leaders emerged to take their place. House officers represent an underused resource for QI. They are skilled at identifying problems but have difficulty executing sustained and complex QI initiatives. Peer leadership is a potent means to mobilize resident-physician participation but may require faculty or staff involvement and support to guarantee its continuity.

  18. Patients' experiences of an open access follow up arrangement in managing inflammatory bowel disease

    PubMed Central

    Rogers, A; Kennedy, A; Nelson, E; Robinson, A

    2004-01-01

    Background: Improving access is a key policy issue in improving quality of care and extending patient choice and participation. People's experience of changing from fixed outpatient appointments to more flexible direct access arrangements for chronic disease has been underexplored. Objectives: To examine patients' views on using an open system of access compared with fixed outpatient appointments as part of a guided self-management intervention for inflammatory bowel disease (IBD). Design: Embedded qualitative study undertaken alongside a randomised controlled trial. Semi-structured interviews were undertaken to obtain an in depth understanding of patients' experience of the change in access arrangements. Participants: A purposive sample (n = 30) was drawn from the intervention group (n = 700) according to a range of responses to the trial baseline and follow up quantitative measures. Results: 28 interviews were included in the analysis. Compared with the previous system of fixed appointments, preference for the new open access system was based on enhanced personal control in contacting services and the view that it fitted better with everyday routine management and the requirement for urgent medical contact when symptoms fail to respond to medication. Preference for retaining fixed appointments was based on a sense of security from gaining access which did not require the individual to initiate the request for medical help. Conclusions: Open access may fit better with patients' self-management of their condition and everyday routines, roles and responsibilities. Ensuring that outpatient organisational arrangements and personnel are responsive to patient initiated requests for appointments is likely to impact on the acceptability of this type of access arrangement. Some people may continue to prefer the fixed appointment system which should be retained if patient choice is to be respected. PMID:15465941

  19. Impaired Inhibitory Force Feedback in Fixed Dystonia.

    PubMed

    Mugge, Winfred; Schouten, Alfred C; van Hilten, Jacobus J; van der Helm, Frans C T

    2016-04-01

    Complex regional pain syndrome (CRPS) is a multifactorial disorder associated with an aberrant host response to tissue injury. About 25% of CRPS patients suffer poorly understood involuntary sustained muscle contractions associated with dysfunctional reflexes that result in abnormal postures (fixed dystonia). A recent modeling study simulated fixed dystonia (FD) caused by aberrant force feedback. The current study aims to validate this hypothesis by experimentally recording the modulation of reflexive force feedback in patients with FD. CRPS patients with and without FD, patients with FD but without CRPS, as well as healthy controls participated in the experiment. Three task instructions and three perturbation characteristics were used to evoke a wide range of responses to force perturbations. During position tasks ("maintain posture"), healthy subjects as well as patients resisted the perturbations, becoming more stiff than when being relaxed (i.e., the relax task). Healthy subjects and CRPS patients without FD were both more compliant during force tasks ("maintain force") than during relax tasks, meaning they actively gave way to the imposed forces. Remarkably, the patients with FD failed to do so. A neuromuscular model was fitted to the experimental data to separate the distinct contributions of position, velocity and force feedback, as well as co-contraction to the motor behavior. The neuromuscular modeling indicated that inhibitory force feedback is deregulated in patients with FD, for both CRPS and non-CRPS patients. From previously published simulation results and the present experimental study, it is concluded that aberrant force feedback plays a role in fixed dystonia.

  20. What happens to Palestine refugees with diabetes mellitus in a primary healthcare centre in Jordan who fail to attend a quarterly clinic appointment?

    PubMed

    Khader, Ali; Ballout, Ghada; Shahin, Yousef; Hababeh, Majed; Farajallah, Loai; Zeidan, Wafaa; Abu-Zayed, Ishtaiwi; Kochi, Arata; Harries, Anthony D; Zachariah, Rony; Kapur, Anil; Shaikh, Irshad; Seita, Akihiro

    2014-03-01

    In a primary healthcare clinic in Jordan to determine: (i) treatment outcomes stratified by baseline characteristics of all patients with diabetes mellitus (DM) ever registered as of June 2012 and (ii) in those who failed to attend the clinic in the quarter (April-June 2012), the number who repeatedly did not attend in subsequent quarters up to 1 year later, again stratified by baseline characteristics. A retrospective cohort study with treatment outcome data collected and analysed using e-health and the cohort analysis approach in UNRWA Nuzha Primary Health Care Clinic for Palestine refugees, Amman, Jordan. As of June 2012, there were 2974 patients with DM ever registered, of whom 2246 (76%) attended the clinic, 279 (9%) did not attend, 81 (3%) died, 67 (2%) were transferred out and 301 (10%) were lost to follow-up. A higher proportion of males and patients with undetermined or poor disease control failed to attend the clinic compared with those who attended the clinic. Of the 279 patients who did not attend the clinic in quarter 2, 2012, 144 (52%) were never seen for four consecutive quarters and were therefore defined as lost to follow-up. There were a few differences between patients who were lost to follow-up and those who re-attended at another visit that included some variation in age and fewer disease-related complications amongst those who were lost to follow-up. This study endorses the value of e-health and cohort analysis for monitoring and managing patients with DM. Just over half of patients who fail to attend a scheduled quarterly appointment are declared lost to follow-up 1 year later, and systems need to be set up to identify and contact such patients so that those who are late for their appointments can be brought back to care and those who might have died or silently transferred out can be correctly recorded. © 2014 John Wiley & Sons Ltd.

  1. Management of rheumatoid arthritis in clinical practice using treat-to-target strategy: Where do we stand in the multi-ethnic Malaysia population?

    PubMed

    Tan, Bee Eng; Lim, Ai Lee; Kan, Sow Lai; Lim, Chong Hong; Ng, Ying Fun; Tng, Serene Li Ching; Hassin, Nur Syakirah; Chandran, Losshenee; Hamid, Norshahida Abdul; Lee, Yvonne Yin Leng

    2017-06-01

    To evaluate the achievement of treat-to-target (T2T) strategy in rheumatoid arthritis (RA) and identify factors associated with failed treatment target in a public rheumatology center. A cross-sectional study was conducted from June 2015 to February 2016. RA patients with disease duration greater than 2 years and under T2T for over a year were invited to the study. Demographic, clinical data, disease activity score of 28 joints (DAS28), and clinical disease activity index (CDAI) were collected in a single routine clinic visit. Treatment target was defined as DAS28 <3.2 or CDAI ≤10. Retrospective chart review was performed to determine reasons of failed treatment target. A total of 371 patients were recruited and 87.1% were female. Mean age and duration of RA were 53.5 years (SD 10.3) and 9.1 years (SD 6.6), respectively. Ethnic distribution was 49% Chinese, 27% Malay, and 24% Indian. T2T was achieved in 81.7% of the cohort. Non-Chinese ethnicity, positive rheumatoid factor, and treatment with three disease modifying anti-rheumatic drugs (DMARDs) were associated with failed treatment target. After controlling for covariates, Malay ethnicity (OR 2.96; 95% CI 1.47-5.96) and treatment with three DMARDs (OR 2.14; 95% CI 1.06-4.35) were associated with failed treatment target. There was no association between age, gender, duration of RA, BMI, smoking status, anti-citrulinated cyclic peptide, and achievement of T2T. The most common reasons of failed treatment target were inability to escalate DMARDs due to side effects (18.8%), lack of biologics fund (15.6%), and persistent disease despite optimum treatment (14.1%). T2T was successfully implemented. Malay patients need aggressive treatment adaptation to achieve optimal outcome.

  2. Rescue EUS-guided intrahepatic biliary drainage for malignant hilar biliary stricture after failed transpapillary re-intervention.

    PubMed

    Minaga, Kosuke; Takenaka, Mamoru; Kitano, Masayuki; Chiba, Yasutaka; Imai, Hajime; Yamao, Kentaro; Kamata, Ken; Miyata, Takeshi; Omoto, Shunsuke; Sakurai, Toshiharu; Watanabe, Tomohiro; Nishida, Naoshi; Kudo, Masatoshi

    2017-11-01

    Treatment of unresectable malignant hilar biliary stricture (UMHBS) is challenging, especially after failure of repeated transpapillary endoscopic stenting. Endoscopic ultrasonography-guided intrahepatic biliary drainage (EUS-IBD) is a recent technique for intrahepatic biliary decompression, but indications for its use for complex hilar strictures have not been well studied. The aim of this study was to assess the feasibility and safety of EUS-IBD for UMHBS after failed transpapillary re-intervention. Retrospective analysis of all consecutive patients with UMHBS of Bismuth II grade or higher who, between December 2008 and May 2016, underwent EUS-IBD after failed repeated transpapillary interventions. The technical success, clinical success, and complication rates were evaluated. Factors associated with clinical ineffectiveness of EUS-IBD were explored. A total of 30 patients (19 women, median age 66 years [range 52-87]) underwent EUS-IBD for UMHBS during the study period. Hilar biliary stricture morphology was classified as Bismuth II, III, or IV in 5, 13, and 12 patients, respectively. The median number of preceding endoscopic interventions was 4 (range 2-14). EUS-IBD was required because the following procedures failed: duodenal scope insertion (n = 4), accessing the papilla after duodenal stent insertion (n = 5), or achieving desired intrahepatic biliary drainage (n = 21). Technical success with EUS-IBD was achieved in 29 of 30 patients (96.7%) and clinical success was attained in 22 of these 29 (75.9%). Mild peritonitis occurred in three of 30 (10%) and was managed conservatively. Stent dysfunction occurred in 23.3% (7/30). There was no procedure-related mortality. On multivariable analysis, Bismuth IV stricture predicted clinical ineffectiveness (odds ratio = 12.7, 95% CI 1.18-135.4, P = 0.035). EUS-IBD may be a feasible and effective rescue alternative with few major complications after failed transpapillary endoscopic re-intervention in patients with UMHBS, particularly for Bismuth II or III strictures.

  3. Formative assessment of GP trainees' clinical skills.

    PubMed

    Wiener-Ogilvie, Sharon; Begg, Drummond

    2012-03-01

    Clinical skill assessment (CSA) has been an integral part of the Royal College of General Practitioners' membership examination (MRCGP) since 2008. It is an expensive, high-stakes examination with first time pass rates ranging from 76.4 to 81.3. In this paper we describe the South East Scotland Deanery, NHS Education Scotland, pilot of a formative clinical skills assessment (fCSA) using the principles of formative assessment and OSCE. The purpose of the study was to assess the acceptability of the fCSA and to examine whether trainees, identified during the fCSA as 'at risk of failing the MRCGP CSA exam', are more likely to fail the MRCGP CSA exam later on in the year. Trainees were assessed in four clinical skills stations under exam conditions. After each station they were given verbal feedback and subsequently both trainee and their trainer received written feedback. We assessed the value of the exercise through written feedback from trainees and trainers. Each trainee's performance in fCSA was triangulated with trainer assessment to identify 'flagged trainees'. We compared flagged and non-flagged trainees' performance in MRCGP CSA. Both trainees and trainers highly rated the fCSA. Overall 97% of non-flagged trainees have passed the RCGP CSA exam by May of that year in comparison to 80% of flagged trainees who have passed the RCGP CSA (P = 0.005). Trainers and trainees rated the fCSA as excellent and useful. We were able to demonstrate that the fCSA can be used to identify those trainees likely to fail the RCGP CSA. Contrary to reservations about the potential to demoralise trainees, the fCSA was viewed as a useful and a positive experience by both trainees and trainers. In addition, we suggest that feedback from fCSA was useful in triggering appropriate educational interventions. Early intervention with trainees who are predicted to fail the CSA has the potential to reduce deaneries overall fail rate. Preventing one trainee failure could save over £30 000.

  4. Safety and Efficacy of Transcatheter Aortic Valve Replacement in the Treatment of Pure Aortic Regurgitation in Native Valves and Failing Surgical Bioprostheses: Results From an International Registry Study.

    PubMed

    Sawaya, Fadi J; Deutsch, Marcus-André; Seiffert, Moritz; Yoon, Sung-Han; Codner, Pablo; Wickramarachchi, Upul; Latib, Azeem; Petronio, A Sonia; Rodés-Cabau, Josep; Taramasso, Maurizio; Spaziano, Marco; Bosmans, Johan; Biasco, Luigi; Mylotte, Darren; Savontaus, Mikko; Gheeraert, Peter; Chan, Jason; Jørgensen, Troels H; Sievert, Horst; Mocetti, Marco; Lefèvre, Thierry; Maisano, Francesco; Mangieri, Antonio; Hildick-Smith, David; Kornowski, Ran; Makkar, Raj; Bleiziffer, Sabine; Søndergaard, Lars; De Backer, Ole

    2017-05-22

    The aim of this study was to evaluate the use of transcatheter heart valves (THV) for the treatment of noncalcific pure native aortic valve regurgitation (NAVR) and failing bioprosthetic surgical heart valves (SHVs) with pure severe aortic regurgitation (AR). Limited data are available about the "off-label" use of transcatheter aortic valve replacement (TAVR) to treat pure severe AR. The study population consisted of patients with pure severe AR treated by TAVR at 18 different centers. Study endpoints were device success, early safety, and clinical efficacy at 30 days, as defined by Valve Academic Research Consortium 2 criteria. A total of 146 patients were included, 78 patients in the NAVR group and 68 patients in the failing SHV group. In the NAVR group, device success, early safety, and clinical efficacy were 72%, 66%, and 61%, respectively. Device success and clinical efficacy were significantly better with newer generation THVs compared with old-generation THVs (85% vs. 54% and 75% vs. 46%, respectively, p < 0.05); this was mainly due to less second THV implantations and a lower rate of moderate to severe paravalvular regurgitation (10% vs. 24% and 3% vs. 27%, respectively). Independent predictors of 30-day mortality were body mass index <20 kg/m 2 , STS surgical risk score >8%, major vascular or access complication, and moderate to severe AR. In the failing SHV group, device success, early safety, and clinical efficacy were 71%, 90%, and 77%, respectively. TAVR for pure NAVR remains a challenging condition, with old-generation THVs being associated with THV embolization and migration and significant paravalvular regurgitation. Newer generation THVs show more promising outcomes. For those patients with severe AR due to failing SHVs, TAVR is a valuable therapeutic option. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Treatment of chronic diabetic lower extremity ulcers with advanced therapies: a prospective, randomised, controlled, multi-centre comparative study examining clinical efficacy and cost.

    PubMed

    Zelen, Charles M; Serena, Thomas E; Gould, Lisa; Le, Lam; Carter, Marissa J; Keller, Jennifer; Li, William W

    2016-04-01

    Advanced therapies such as bioengineered skin substitutes (BSS) and dehydrated human amnion/chorion membrane (dHACM) have been shown to promote healing of chronic diabetic ulcers. An interim analysis of data from 60 patients enrolled in a prospective, randomised, controlled, parallel group, multi-centre clinical trial showed that dHACM (EpiFix, MiMedx Group Inc., Marietta, GA) is superior to standard wound care (SWC) and BSS (Apligraf, Organogenesis, Inc., Canton, MA) in achieving complete wound closure within 4-6 weeks. Rates and time to closure at a longer time interval and factors influencing outcomes remained unassessed; therefore, the study was continued in order to achieve at least 100 patients. With the larger cohort, we compare clinical outcomes at 12 weeks in 100 patients with chronic lower extremity diabetic ulcers treated with weekly applications of Apligraf (n = 33), EpiFix (n = 32) or SWC (n = 35) with collagen-alginate dressing as controls. A Cox regression was performed to analyse the time to heal within 12 weeks, adjusting for all significant covariates. A Kaplan-Meier analysis was conducted to compare time-to-heal within 12 weeks for the three treatment groups. Clinical characteristics were well matched across study groups. The proportion of wounds achieving complete closure within the 12-week study period were 73% (24/33), 97% (31/32), and 51% (18/35) for Apligraf, EpiFix and SWC, respectively (adjusted P = 0·00019). Subjects treated with EpiFix had a very significant higher probability of their wounds healing [hazard ratio (HR: 5·66; adjusted P: 1·3 x 10(-7) ] compared to SWC alone. No difference in probability of healing was observed for the Apligraf and SWC groups. Patients treated with Apligraf were less likely to heal than those treated with EpiFix [HR: 0·30; 95% confidence interval (CI): 0·17-0·54; unadjusted P: 5·8 x 10(-5) ]. Increased wound size and presence of hypertension were significant factors that influenced healing. Mean time-to-heal within 12 weeks was 47·9 days (95% CI: 38·2-57·7) with Apligraf, 23·6 days (95% CI: 17·0-30·2) with EpiFix group and 57·4 days (95%CI: 48·2-66·6) with the SWC alone group (adjusted P = 3·2 x 10(-7) ). Median number of grafts used per healed wound were six (range 1-13) and 2·5 (range 1-12) for the Apligraf and EpiFix groups, respectively. Median graft cost was $8918 (range $1,486-19,323) per healed wound for the Apligraf group and $1,517 (range $434-25,710) per healed wound in the EpiFix group (P < 0·0001). These results provide further evidence of the clinical and resource utilisation superiority of EpiFix compared to Apligraf for the treatment of lower extremity diabetic wounds. © 2015 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  6. Transpedal access after failed anterograde recanalization of complex below-the-knee and femoropoliteal occlusions in critical limb ischemia.

    PubMed

    Ruzsa, Zoltán; Nemes, Balázs; Bánsághi, Zoltán; Tóth, Károly; Kuti, Ferenc; Kudrnova, Slavka; Berta, Balázs; Hüttl, Kálmán; Merkely, Béla

    2014-05-01

    Successful angioplasty is one of the main factor of limb salvage during critical limb ischemia. In complex femoropopliteal to infrapopliteal occlusions, an anterograde recanalization attempt can fail in up to 20% of the cases. The purpose of this dual center pilot study was to evaluate the acute success and clinical impact of retrograde transpedal access for retrograde below-the-knee and femoropopliteal chronic total occlusions after failed anterograde attempt and to access the late complications at the puncture site. The clinical and angiographic data of 51 consecutive patients with CLI treated by retrograde transpedal recanalization between 2010 and 2011 were evaluated in a pilot study. We have examined the 2-month and 1 year major adverse events (MAEs) and clinical success. In all cases after failure of the anterograde recanalization of occluded below-the-knee segments due to unsuccessful penetration or failed re-entry, the anterior tibial or posterior tibial artery was punctured under fluoroscopic guidance and retrograde recanalization was performed. Direct revascularization was tried firstly following the angiographic zones, but in failed cases indirect revascularization was carried out with increasing the collateral flow to the wound. Successful direct retrograde revascularization was achieved successfully in 40 patients (78.4%) and indirect revascularization was done in 10 patients (19.6%). Revascularization was failed in one patient (2%). MAE at 2 and 12 months follow-up was 6 (11.7%) and 11 (24%). Limb salvage at 2 and 12 months was 93% and 82.3%, respectively. Balloon angioplasty was performed in all interventions and provisional stenting was done in 34 patients (66.7%). One major and three minor vascular complications occurred after the procedure. The mean basal and control creatinine level was 120.9 ± 133.4 and 123.8 ± 131.3 μmol/L (P = 0.83) after the procedure. Failed antegrade attempts to recanalize CTO-s of femoropopliteal and infrapopliteal vessels can be salvaged using a retrograde transpedal access, with a low acute and late complication rate. This technique could be valuable for patients with critical limb ischemia due to femoropopliteal and infrapopliteal occlusions. Copyright © 2013 Wiley Periodicals, Inc.

  7. Surgery or EUS-guided choledochoduodenostomy for malignant distal biliary obstruction after ERCP failure

    PubMed Central

    Artifon, Everson L.A.; Loureiro, Jarbas F.; Baron, Todd H.; Fernandes, Kaie; Kahaleh, Michel; Marson, Fernando P.

    2015-01-01

    Background and Objectives: Endoscopic retrograde cholangiopancreatography (ERCP) is the method of choice for drainage in patients with distal malignant biliary obstruction, but it fails in up to 10% of cases. Percutaneous transhepatic cholangiography (PTC) and surgical bypass are the traditional drainage alternatives. This study aimed to compare technical and clinical success, quality of life, and survival of surgical biliary bypass or hepaticojejunostomy (HJT) and endoscopic ultrasound (EUS)-guided choledochoduodenostomy (CDT) in patients with distal malignant bile duct obstruction and failed ERCP. Patients and Methods: A prospective, randomized trial was conducted. From March 2011 to September 2013, 32 patients with malignant distal biliary obstruction and failed ERCP were studied. The HJT group consisted of 15 patients and the CDT group consisted of 14 patients. Technical and clinical success, quality of life, and survival were assessed prospectively. Results: Technical success was 94% (15/16) in the HJT group and 88% (14/16) in the CDT group (P = 0.598). Clinical success occurred in 14 (93%) patients in the HJT group and in 10 (71%) patients in the CDT group (P = 0.169). During follow-up, a statistically significant difference was seen in mean functional capacity scores, physical health, pain, social functioning, and emotional and mental health aspects in both techniques (P < 0.05). The median survival time in both groups was the same (82 days). Conclusion: Data relating to technical and clinical success, quality of life, and survival were similar in patients who underwent HJT and CDT drainage after failed ERCP for malignant distal biliary obstruction. PMID:26374583

  8. Targeted traction of impacted teeth with C-tube miniplates.

    PubMed

    Chung, Kyu-Rhim; Kim, Yong; Ahn, Hyo-Won; Lee, Dongjoo; Yang, Dong-Min; Kim, Seong-Hun; Nelson, Gerald

    2014-09-01

    Orthodontic traction of impacted teeth has typically been performed using full fixed appliance as anchorage against the traction force. This conventional approach can be difficult to apply in the mixed dentition if the partial fixed appliance offers an insufficient anchor unit. In addition, full fixed appliance can induce unwanted movement of adjacent teeth. This clinical report presents 3 cases where impacted teeth were recovered in the mixed or transitional dentition with skeletal anchorage on the opposite arch without full fixed appliance. Instead, intermaxillary traction was used to bring the impacted teeth into position. With this approach, side effects on teeth and periodontal tissues adjacent to the impaction were minimized.

  9. Prosthetic rehabilitation with an implant-supported fixed prosthesis using computer-aided design and computer-aided manufacturing dental technology for a patient with a mandibulectomy: A clinical report.

    PubMed

    Yoon, Hyung-In; Han, Jung-Suk

    2016-02-01

    The fabrication of dental prostheses with computer-aided design and computer-aided manufacturing shows acceptable marginal fits and favorable treatment outcomes. This clinical report describes the management of a patient who had undergone a mandibulectomy and received an implant-supported fixed prosthesis by using additive manufacturing for the framework and subtractive manufacturing for the monolithic zirconia restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Clinical utility of an automated instrument for gram staining single slides.

    PubMed

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-06-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.

  11. Sofosbuvir/ledipasvir fixed-dose combination for treatment of chronic hepatitis C virus infection in children.

    PubMed

    Rizza, S A; Nehra, V; Temesgen, Z

    2017-08-01

    The United States Food and Drug Administration recently approved sofosbuvir and the fixed-dose combination of ledipasvir/sofosbuvir for the treatment of hepatitis C virus (HCV) infection in children ages 12 to 17. These are the first direct-acting antiviral treatments approved for children and adolescents with HCV. Pharmacokinetic data confirm equivalent drug exposure in this population as that found in adults during clinical trials. The efficacy and safety of these drugs has been shown in clinical trials. Copyright 2017 Clarivate Analytics.

  12. Intensification of Diabetes Therapy and Time Until A1C Goal Attainment Among Patients With Newly Diagnosed Type 2 Diabetes Who Fail Metformin Monotherapy Within a Large Integrated Health System.

    PubMed

    Pantalone, Kevin M; Wells, Brian J; Chagin, Kevin M; Ejzykowicz, Flavia; Yu, Changhong; Milinovich, Alex; Bauman, Janine M; Kattan, Michael W; Rajpathak, Swapnil; Zimmerman, Robert S

    2016-09-01

    "Clinical inertia" has been used to describe the delay in the intensification of type 2 diabetes treatment among patients with poor glycemic control. Previous studies may have exaggerated the prevalence of clinical inertia by failing to adequately monitor drug dose changes and nonmedication interventions. This project evaluated the intensification of diabetes therapy and hemoglobin A1c (A1C) goal attainment among patients with newly diagnosed type 2 diabetes when metformin monotherapy failed. The electronic health record at Cleveland Clinic was used to identify patients with newly diagnosed type 2 diabetes between 2005 and 2013 who failed to reach the A1C goal after 3 months of metformin monotherapy. A time-dependent survival analysis was used to compare the time until A1C goal attainment in patients who received early intensification of therapy (within 6 months of metformin failure) or late intensification. The analysis was performed for A1C goals of 7% (n = 1,168), 7.5% (n = 679), and 8% (n = 429). Treatment was intensified early in 62%, 69%, and 72% of patients when poor glycemic control was defined as an A1C >7%, >7.5%, and >8%, respectively. The probability of undergoing an early intensification was greater the higher the A1C category. Time until A1C goal attainment was shorter among patients who received early intensification regardless of the A1C goal (all P < 0.05). A substantial number of patients with newly diagnosed type 2 diabetes fail to undergo intensification of therapy within 6 months of metformin monotherapy failure. Early intervention in patients when metformin monotherapy failed resulted in more rapid attainment of A1C goals. © 2016 by the American Diabetes Association.

  13. Proposed criteria to differentiate heterogeneous eosinophilic gastrointestinal disorders of the esophagus, including eosinophilic esophageal myositis.

    PubMed

    Sato, Hiroki; Nakajima, Nao; Takahashi, Kazuya; Hasegawa, Go; Mizuno, Ken-Ichi; Hashimoto, Satoru; Ikarashi, Satoshi; Hayashi, Kazunao; Honda, Yutaka; Yokoyama, Junji; Sato, Yuichi; Terai, Shuji

    2017-04-07

    To define clinical criteria to differentiate eosinophilic gastrointestinal disorder (EoGD) in the esophagus. Our criteria were defined based on the analyses of the clinical presentation of eosinophilic esophagitis (EoE), subepithelial eosinophilic esophagitis (sEoE) and eosinophilic esophageal myositis (EoEM), identified by endoscopy, manometry and serum immunoglobulin E levels (s-IgE), in combination with histological and polymerase chain reaction analyses on esophageal tissue samples. In five patients with EoE, endoscopy revealed longitudinal furrows and white plaques in all, and fixed rings in two. In one patient with sEoE and four with EoEM, endoscopy showed luminal compression only. Using manometry, failed peristalsis was observed in patients with EoE and sEoE with some variation, while EoEM was associated with hypercontractile or hypertensive peristalsis, with elevated s-IgE. Histology revealed the following eosinophils per high-power field values. EoE = 41.4 ± 7.9 in the epithelium and 2.3 ± 1.5 in the subepithelium; sEoE = 3 in the epithelium and 35 in the subepithelium (conventional biopsy); EoEM = none in the epithelium, 10.7 ± 11.7 in the subepithelium (conventional biopsy or endoscopic mucosal resection) and 46.8 ± 16.5 in the muscularis propria (peroral esophageal muscle biopsy). Presence of dilated epithelial intercellular space and downward papillae elongation were specific to EoE. Eotaxin-3, IL-5 and IL-13 were overexpressed in EoE. Based on clinical and histological data, we identified criteria, which differentiated between EoE, sEoE and EoEM, and reflected a different pathogenesis between these esophageal EoGDs.

  14. Proposed criteria to differentiate heterogeneous eosinophilic gastrointestinal disorders of the esophagus, including eosinophilic esophageal myositis

    PubMed Central

    Sato, Hiroki; Nakajima, Nao; Takahashi, Kazuya; Hasegawa, Go; Mizuno, Ken-ichi; Hashimoto, Satoru; Ikarashi, Satoshi; Hayashi, Kazunao; Honda, Yutaka; Yokoyama, Junji; Sato, Yuichi; Terai, Shuji

    2017-01-01

    AIM To define clinical criteria to differentiate eosinophilic gastrointestinal disorder (EoGD) in the esophagus. METHODS Our criteria were defined based on the analyses of the clinical presentation of eosinophilic esophagitis (EoE), subepithelial eosinophilic esophagitis (sEoE) and eosinophilic esophageal myositis (EoEM), identified by endoscopy, manometry and serum immunoglobulin E levels (s-IgE), in combination with histological and polymerase chain reaction analyses on esophageal tissue samples. RESULTS In five patients with EoE, endoscopy revealed longitudinal furrows and white plaques in all, and fixed rings in two. In one patient with sEoE and four with EoEM, endoscopy showed luminal compression only. Using manometry, failed peristalsis was observed in patients with EoE and sEoE with some variation, while EoEM was associated with hypercontractile or hypertensive peristalsis, with elevated s-IgE. Histology revealed the following eosinophils per high-power field values. EoE = 41.4 ± 7.9 in the epithelium and 2.3 ± 1.5 in the subepithelium; sEoE = 3 in the epithelium and 35 in the subepithelium (conventional biopsy); EoEM = none in the epithelium, 10.7 ± 11.7 in the subepithelium (conventional biopsy or endoscopic mucosal resection) and 46.8 ± 16.5 in the muscularis propria (peroral esophageal muscle biopsy). Presence of dilated epithelial intercellular space and downward papillae elongation were specific to EoE. Eotaxin-3, IL-5 and IL-13 were overexpressed in EoE. CONCLUSION Based on clinical and histological data, we identified criteria, which differentiated between EoE, sEoE and EoEM, and reflected a different pathogenesis between these esophageal EoGDs. PMID:28428721

  15. Declining prevalence of HIV-1 drug resistance in treatment-failing patients: a clinical cohort study.

    PubMed

    Di Giambenedetto, Simona; Bracciale, Laura; Colafigli, Manuela; Colatigli, Manuela; Cattani, Paola; Pinnetti, Carmen; Pannetti, Carmen; Bacarelli, Alessandro; Prosperi, Mattia; Fadda, Giovanni; Cauda, Roberto; De Luca, Andrea

    2007-01-01

    A major barrier to successful viral suppression in HIV type 1 (HIV-1)-infected individuals is the emergence of virus resistant to antiretroviral drugs. We explored the evolution of genotypic drug resistance prevalence in treatment-failing patients from 1999 to 2005 in a clinical cohort. Prevalence of major International AIDS Society-USA HIV-1 drug resistance mutations was measured over calendar years in a population with treatment failure and undergoing resistance testing. Predictors of the presence of resistance mutations were analysed by logistic regression. Significant reductions of the prevalence of resistance to all three drug classes examined were observed. This was accompanied by a reduction in the proportion of treatment-failing patients. Independent predictors of drug resistance were the earlier calendar year, prior use of suboptimal nucleoside analogue therapy, male sex and higher CD4 levels at testing. In a single clinical cohort, we observed a decrease in the prevalence of resistance to all three examined antiretroviral drug classes over time. If this finding is confirmed in multicentre cohorts it may translate into reduced transmission of drug-resistant virus from treated patients.

  16. The dishonest dean's letter: an analysis of 532 dean's letters from 99 U.S. medical schools.

    PubMed

    Edmond, M; Roberson, M; Hasan, N

    1999-09-01

    To quantify the censure of potentially negative information in dean's letters. Concordance between 532 dean's letters and the corresponding transcripts was determined for six variables (failing grade in a preclinical course, marginal preclinical course grade, failing grade for a clinical rotation, marginal clinical rotation grade, leave of absence, and requirement to repeat an entire year of medical school). The evaluated variables were not found in the dean's letters 27% to 50% of the time that they were present on the transcripts. In three of nine instances (33%), a failing grade in a clinical rotation was not included. Four students had been required to repeat an entire year, but this was noted in only two cases. In toto, 35 of 104 (34%) of the variables identified on the transcripts were not reported. In addition, deans were significantly less likely to report a student's USMLE 1 score if the score was at or below the 20th percentile (p = .03). Some deans suppress negative information in their letters and potentially obfuscate the residency selection process.

  17. The failure mode of two reabsorbable fixation systems: Swivelock with Fibertape versus Bio-Corkscrew with Fiberwire in bovine rotator cuff.

    PubMed

    De Carli, Angelo; Lanzetti, Riccardo Maria; Monaco, Edoardo; Labianca, Luca; Mossa, Luigi; Ferretti, Andrea; Feretti, Andrea

    2012-11-01

    Despite technical advances in rotator cuff surgery, recurrent or persistent defects in the repaired tendon continue to occur. The improved strength of sutures and suture anchors has shown that the most common site of failure is the suture-tendon interface. The purpose of this study was to compare two different types of repair under both cyclic and load-to-failure conditions. The hypothesis is that the use of a fixation system with knotless anchor and taped suture results in better biomechanical performance, under both cyclic and load-to-failure conditions. Thirty bovine shoulder specimens were randomly assigned to two group tests: the Swivelock 5-mm anchor with Fibertape (Group A) and the Bio-Corkscrew 5 mm with Fiberwire (Group B). We simulated the reconstruction of a rotator cuff tear with a single-row technique, performing a tenodesis with types A and B fixation. Each specimen underwent cyclic testing from 5 to 30 N for 30 cycles, followed by load-to-failure testing, in order to calculate the ultimate failure load (UFL). Load-to-failure tests revealed a significantly higher UFL in Group A than in Group B. Wire fixing failed at the anchor loop whereas tape fixing failed at the sutures, suture-tendon interface, and anchors. Cyclic testing revealed no significantly greater slippage between the two groups. Stiffness values were not statistically significantly different. In all cases, tendons remained intact until the end of the cyclic testing. The tape structure is biomechanically stronger than the wire structure.

  18. The Child and Adolescent Psychiatry Trials Network

    ERIC Educational Resources Information Center

    March, John S.; Silva, Susan G.; Compton, Scott; Anthony, Ginger; DeVeaugh-Geiss, Joseph; Califf, Robert; Krishnan, Ranga

    2004-01-01

    Objective: The current generation of clinical trials in pediatric psychiatry often fails to maximize clinical utility for practicing clinicians, thereby diluting its impact. Method: To attain maximum clinical relevance and acceptability, the Child and Adolescent Psychiatry Trials Network (CAPTN) will transport to pediatric psychiatry the practical…

  19. Verification of finite element analysis of fixed partial denture with in vitro electronic strain measurement.

    PubMed

    Wang, Gaoqi; Zhang, Song; Bian, Cuirong; Kong, Hui

    2016-01-01

    The purpose of the study was to verify the finite element analysis model of three-unite fixed partial denture with in vitro electronic strain analysis and analyze clinical situation with the verified model. First, strain gauges were attached to the critical areas of a three-unit fixed partial denture. Strain values were measured under 300 N load perpendicular to the occlusal plane. Secondly, a three-dimensional finite element model in accordance with the electronic strain analysis experiment was constructed from the scanning data. And the strain values obtained by finite element analysis and in vitro measurements were compared. Finally, the clinical destruction of the fixed partial denture was evaluated with the verified finite element analysis model. There was a mutual agreement and consistency between the finite element analysis results and experimental data. The finite element analysis revealed that failure will occur in the veneer layer on buccal surface of the connector under occlusal force of 570 N. The results indicate that the electronic strain analysis is an appropriate and cost saving method to verify the finite element model. The veneer layer on buccal surface of the connector is the weakest area in the fixed partial denture. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  20. A new cable-tie based sternal closure system: description of the device, technique of implantation and first clinical evaluation

    PubMed Central

    2012-01-01

    Background Wire closure still remains the preferred technique despite reasonable disadvantages. Associated complications, such as infection and sternal instability, cause time- and cost-consuming therapies. We present a new tool for sternal closure with its first clinical experience and results. Methods The sternal ZipFixTM System is based on the cable-tie principle. It primarily consists of biocompatible Poly-Ether-Ether-Ketone implants and is predominantly used peristernally through the intercostal space. The system provides a large implant-to-bone contact for better force distribution and for avoiding bone cut through. Results 50 patients were closed with the ZipFixTM system. No sternal instability was observed at 30 days. Two patients developed a mediastinitis that necessitated the removal of the device; however, the ZipFixTM were intact and the sternum remained stable. Conclusions In our initial evaluation, the short-term results have shown that the sternal ZipFixTM can be used safely and effectively. It is fast, easy to use and serves as a potential alternative for traditional wire closure. PMID:22731778

  1. Delay-Aware Energy-Efficient Routing towards a Path-Fixed Mobile Sink in Industrial Wireless Sensor Networks.

    PubMed

    Wu, Shaobo; Chou, Wusheng; Niu, Jianwei; Guizani, Mohsen

    2018-03-18

    Wireless sensor networks (WSNs) involve more mobile elements with their widespread development in industries. Exploiting mobility present in WSNs for data collection can effectively improve the network performance. However, when the sink (i.e., data collector) path is fixed and the movement is uncontrollable, existing schemes fail to guarantee delay requirements while achieving high energy efficiency. This paper proposes a delay-aware energy-efficient routing algorithm for WSNs with a path-fixed mobile sink, named DERM, which can strike a desirable balance between the delivery latency and energy conservation. We characterize the object of DERM as realizing the energy-optimal anycast to time-varying destination regions, and introduce a location-based forwarding technique tailored for this problem. To reduce the control overhead, a lightweight sink location calibration method is devised, which cooperates with the rough estimation based on the mobility pattern to determine the sink location. We also design a fault-tolerant mechanism called track routing to tackle location errors for ensuring reliable and on-time data delivery. We comprehensively evaluate DERM by comparing it with two canonical routing schemes and a baseline solution presented in this work. Extensive evaluation results demonstrate that DERM can provide considerable energy savings while meeting the delay constraint and maintaining a high delivery ratio.

  2. Breaking evolutionary constraint with a tradeoff ratchet

    PubMed Central

    de Vos, Marjon G. J.; Dawid, Alexandre; Sunderlikova, Vanda; Tans, Sander J.

    2015-01-01

    Epistatic interactions can frustrate and shape evolutionary change. Indeed, phenotypes may fail to evolve when essential mutations are only accessible through positive selection if they are fixed simultaneously. How environmental variability affects such constraints is poorly understood. Here, we studied genetic constraints in fixed and fluctuating environments using the Escherichia coli lac operon as a model system for genotype–environment interactions. We found that, in different fixed environments, all trajectories that were reconstructed by applying point mutations within the transcription factor–operator interface became trapped at suboptima, where no additional improvements were possible. Paradoxically, repeated switching between these same environments allows unconstrained adaptation by continuous improvements. This evolutionary mode is explained by pervasive cross-environmental tradeoffs that reposition the peaks in such a way that trapped genotypes can repeatedly climb ascending slopes and hence, escape adaptive stasis. Using a Markov approach, we developed a mathematical framework to quantify the landscape-crossing rates and show that this ratchet-like adaptive mechanism is robust in a wide spectrum of fluctuating environments. Overall, this study shows that genetic constraints can be overcome by environmental change and that cross-environmental tradeoffs do not necessarily impede but also, can facilitate adaptive evolution. Because tradeoffs and environmental variability are ubiquitous in nature, we speculate this evolutionary mode to be of general relevance. PMID:26567153

  3. Delay-Aware Energy-Efficient Routing towards a Path-Fixed Mobile Sink in Industrial Wireless Sensor Networks

    PubMed Central

    Wu, Shaobo; Chou, Wusheng; Niu, Jianwei; Guizani, Mohsen

    2018-01-01

    Wireless sensor networks (WSNs) involve more mobile elements with their widespread development in industries. Exploiting mobility present in WSNs for data collection can effectively improve the network performance. However, when the sink (i.e., data collector) path is fixed and the movement is uncontrollable, existing schemes fail to guarantee delay requirements while achieving high energy efficiency. This paper proposes a delay-aware energy-efficient routing algorithm for WSNs with a path-fixed mobile sink, named DERM, which can strike a desirable balance between the delivery latency and energy conservation. We characterize the object of DERM as realizing the energy-optimal anycast to time-varying destination regions, and introduce a location-based forwarding technique tailored for this problem. To reduce the control overhead, a lightweight sink location calibration method is devised, which cooperates with the rough estimation based on the mobility pattern to determine the sink location. We also design a fault-tolerant mechanism called track routing to tackle location errors for ensuring reliable and on-time data delivery. We comprehensively evaluate DERM by comparing it with two canonical routing schemes and a baseline solution presented in this work. Extensive evaluation results demonstrate that DERM can provide considerable energy savings while meeting the delay constraint and maintaining a high delivery ratio. PMID:29562628

  4. Our Treatment Approaches in Severe Maxillofacial Injuries Occurring After Failed Suicide Attempts Using Long-Barreled Guns.

    PubMed

    Kucuker, Ismail; Şimşek, Tekin; Keles, Musa Kemal; Yosma, Engin; Aksakal, Ibrahim Alper; Demir, Ahmet

    2016-03-01

    Maxillofacial traumas with long-barreled guns may sometimes cause catastrophic results by means of smashing in facial structures. In these patients, reconstruction strategies of both fragmented/lost soft and hard tissues still remain controversial. In their clinic, the authors treated 5 patients with severely injured face after failed suicide attempt between 2008 and 2013. In this study, the authors aimed to present their clinical experiences on these severely injured maxillofacial gunshot traumas and offer a treatment algorithm to gain a result as possible as satisfactory in terms of functionality and appearance.

  5. Wichita fusion nail for patients with failed total knee arthroplasty and active infection.

    PubMed

    Barsoum, Wael K; Hogg, Christopher; Krebs, Viktor; Klika, Alison K

    2008-01-01

    In the study reported here, we retrospectively evaluated short-term results of knee arthrodesis using the Wichita fusion nail (WFN) in patients with active infection. Clinical examinations, x-rays, time to union, knee pain after fusion, and ambulatory status were compared in 7 patients who received the WFN. Mean fusion rate was 86%, mean time to fusion was 9.8 months, and mean complication rate was 57%. Complication rates were high, but clinical outcomes were acceptable, supporting use of WFN as a reasonable way to salvage failed total knee arthroplasty in patients with active infection.

  6. Screening in ionic systems: simulations for the Lebowitz length.

    PubMed

    Kim, Young C; Luijten, Erik; Fisher, Michael E

    2005-09-30

    Simulations of the Lebowitz length, xiL (T, rho), are reported for the restricted primitive model hard-core (diameter a) 1:1 electrolyte for densities rho approximately < 4rho(c) and T(c) approximately < T approximately < 40T(c). Finite-size effects are elucidated for the charge fluctuations in various subdomains that serve to evaluate xiL. On extrapolation to the bulk limit for T approximately > 10T(c) the exact low-density expansions are seen to fail badly when rho > 1/10 rho(c) (with rho(c)a3 approximately = 0.08). At higher densities xiL rises above the Debye length, xiD proportional to square root(T/rho), by 10%-30% (up to rho approximately =1.3rho(c)); the variation is portrayed fairly well by the generalized Debye-Hückel theory. On approaching criticality at fixed rho or fixed T, xiL (T, rho) remains finite with xiL(c) approximately = 0.30a approximately = 1.3xiD(c) but displays a weak entropylike singularity.

  7. Quantum Interactive Dualism: An Alternative to Materialism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stapp, Henry P

    2005-06-01

    Materialism rest implicitly upon the general conception of nature promoted by Galileo and Newton during the seventeenth century. It features the causal closure of the physical: The course of physically described events for all time is fixed by laws that refer exclusively to the physically describeable features of nature, and initial conditions on these feature. No reference to subjective thoughts or feeling of human beings enter. That simple conception of nature was found during the first quarter of the twentieth century to be apparently incompatible with the empirical facts. The founders of quantum theory created a new fundamental physical theory,more » quantum theory, which introduced crucially into the causal structure certain conscious choices made by human agents about how they will act. These conscious human choices are ''free'' in the sense that they are not fixed by the known laws. But they can influence the course of physically described events. Thus the principle of the causal closure of the physical fails. Applications in psycho-neuro-dynamics are described.« less

  8. [Arthroscopic repair of meniscus injury with Fast-fix under local anesthesia].

    PubMed

    Wang, Jiang-tao; Liu, Yu-jie; Wang, Jun-liang; Qu, Feng; Yuan, Bang-tuo; Zhao, Gang; Shen, Xue-zhen; Zhu, Juan-li; Liu, Yang

    2014-08-01

    To evaluate the clinical outcome of arthroscopic repair method of meniscus injury with Fast-fix under local anesthesia. From October 2005 to September 2012,106 patients with meniscus injuries admitted into our - hospital were studied, including 74 males and 32 females, ranging in age from 13 to 71 years old, averaged 27.6 years old. The duration of the disease ranged from 15 days to 5 years. The main clinical manifestations included knee joint pain after exercise, joint locking, pressing pain of knee joint and positive McMurray signs. The MRI showed meniscus tear or degeneration. Arthroscopic repairing surgeries were performed with Fast-fix under local anesthesia. Each patient was assessed with VAS pain evaluation and Lysholm knee-joint score system before and after operation. All the patients were followed up more than 1 year. One hundred and 2 patients were followed up by recording subjective symptoms, clinical examinations and questions naires for an average of 2.6 years (ranged, 1.1 to 8 years), and 4 patients lost follow-up. All the 102 patients had no anesthetic complications. Ninety-six patients had normal subjective symptom and clinical examinations. Four patients had a mild ache with activities,2 patients had moderate pain after activities with joint space pressing pain. VAS pain evaluation and Lysholm knee-joint score after operation both were much better than that before operation. onclusion: Local anesthesia can provide nice circumstances for surgeries. Arthroscopic repair using Fast-fix is an idea method for meniscus injury, especially for the posterior horn tear of medial meniscus, which is simple and convenient with less complications, and satisfactory results.

  9. No difference in terms of radiostereometric analysis between fixed- and mobile-bearing total knee arthroplasty: a randomized, single-blind, controlled trial.

    PubMed

    Schotanus, M G M; Pilot, P; Kaptein, B L; Draijer, W F; Tilman, P B J; Vos, R; Kort, N P

    2017-09-01

    A concern that arises with any new prosthesis is whether it will achieve satisfactory long-term implant stability. The gold standard of assessing the quality of fixation in a new or relatively new implant is to undertake a randomized controlled trial using radiostereometric analysis. It was hypothesized that both mobile-bearing total knee arthroplasty and fixed-bearing total knee arthroplasty have comparable migration patterns at 2-year follow-up. This study investigated two types of cemented total knee arthroplasty, the mobile- or fixed-bearing variant from the same family with use of radiostereometric analysis. This prospective, patient-blinded, randomized, controlled trial was designed to investigate early migration of the tibia component after two years of follow-up with use of radiostereometric analysis. A total of 50 patients were randomized to receive a mobile- or fixed-bearing TKA from the same family. Patients were evaluated during 2-year follow-up, including radiostereometric analysis, physical and clinical examination and patient reported outcome measures (PROMs). At two-year follow-up, the mean (±SD) maximum total point motion (MTPM) in the fixed-bearing group was 0.82 (±1.16) versus 0.92 mm (±0.64) in the mobile-bearing group (p = n.s) with the largest migration seen during the first 6 weeks (0.45 ± 0.32 vs. 0.54 ± 0.30). The clinical outcome and PROMs significantly improved within each group, not between both groups. Measuring early micromotion is useful for predicting clinical loosening that can lead to revision. The results of this study demonstrate that early migration of the mobile-bearing is similar to that of the fixed-bearing component at two years and was mainly seen in the first weeks after implantation. Randomized, single-blind, controlled trial, Level I.

  10. A cost-effectiveness analysis of fixed-combination therapies in patients with open-angle glaucoma: a European perspective.

    PubMed

    Hommer, A; Wickstrøm, J; Friis, M M; Steeds, C; Thygesen, J; Ferreras, A; Gouws, P; Buchholz, P

    2008-04-01

    To compare the efficacy and cost implications of the use of the intraocular pressure-lowering prostaglandin analogues bimatoprost, travoprost, and latanoprost as fixed-combination therapies with timolol, a beta-adrenergic receptor antagonist. A decision analytic cost-effectiveness model was constructed. Since no head-to-head studies comparing the three treatment options exist, the analysis was based on an indirect comparison. Hence, the model was based on efficacy data from five randomized, controlled, clinical studies. The studies were comparable with respect to study design, time horizon, patient population and type of end point presented. The measure of effectiveness was the percentage reduction of the intraocular pressure level from baseline. The cost evaluated was the cost of medication and clinical visits to the ophthalmologist. All drug costs were market prices inclusive of value-added tax, and visit costs were priced using official physician fees. Cost-effectiveness analyses were carried out in five European countries: Spain, Italy, United Kingdom, Norway and Sweden. The time horizon for the analyses was 3 months. The analysis showed that fixed-combination bimatoprost/timolol was more effective and less costly than fixed-combination travoprost/timolol and fixed-combination latanoprost/timolol in three out of the five countries analyzed. In two countries, bimatoprost/timolol was less costly than latanoprost/timolol, and cost the same as travoprost/timolol. This cost-effectiveness analysis showed that the fixed combination of bimatoprost 0.03%/timolol 0.5% administered once daily was a cost-effective treatment option for patients with primary open-angle glaucoma. This study was limited by available clinical data: without a head-to-head trial, indirect comparisons were necessary. In the United Kingdom, Sweden, Norway, Italy, and Spain, from a health service viewpoint, bimatoprost/timolol was a slightly more effective as well as less costly treatment strategy when compared to both travoprost/timolol and latanoprost/timolol.

  11. Weighted re-randomization tests for minimization with unbalanced allocation.

    PubMed

    Han, Baoguang; Yu, Menggang; McEntegart, Damian

    2013-01-01

    Re-randomization test has been considered as a robust alternative to the traditional population model-based methods for analyzing randomized clinical trials. This is especially so when the clinical trials are randomized according to minimization, which is a popular covariate-adaptive randomization method for ensuring balance among prognostic factors. Among various re-randomization tests, fixed-entry-order re-randomization is advocated as an effective strategy when a temporal trend is suspected. Yet when the minimization is applied to trials with unequal allocation, fixed-entry-order re-randomization test is biased and thus compromised in power. We find that the bias is due to non-uniform re-allocation probabilities incurred by the re-randomization in this case. We therefore propose a weighted fixed-entry-order re-randomization test to overcome the bias. The performance of the new test was investigated in simulation studies that mimic the settings of a real clinical trial. The weighted re-randomization test was found to work well in the scenarios investigated including the presence of a strong temporal trend. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Rehabilitation with implant-supported overdentures in total edentulous patients: A review

    PubMed Central

    Segura-Andrés, Gustavo; Faus-López, Joan; Agustín-Panadero, Rubén

    2013-01-01

    Objectives: The main aim of this review article is to discuss implant-supported overdentures (ISOs) as treatment in edentulous patients. Besides, we will try to discuss among the different treatment options in such patients and to analyze their validity when ISOs are compared with other clinical modalities. At the same time, we will try to suggest clinical guidelines supported by current clinical studies. Material and methods: We performed a Medline search and review of pertinent articles on the mentioned subject from 1986 to 2011. As a searching strategy, we used the following words: implant-supported overdentures, attachment systems, Locator attachment, cantilever, fixed prosthesis. Results and conclusions: Implant-supported overdentures constitute an accurate and predictable treatment option and achieve a higher patients’ satisfaction. This type of treatment constitutes a cheaper treatment than fixed prostheses and in some patients, with loss of lip support or with an interoclusal space larger than 15 mm, the choice of implant-supported overdentures seems to prevent future aesthetic or phonetic problems. Key words:Overdentures, implant occlusion, implant rehabilitation, total edentulous rehabilitation, fixed prosthesis. PMID:24455093

  13. Immediate Loading of Tapered Implants Placed in Postextraction Sockets and Healed Sites.

    PubMed

    Han, Chang-Hun; Mangano, Francesco; Mortellaro, Carmen; Park, Kwang-Bum

    2016-07-01

    The aim of the present study was to compare the survival, stability, and complications of immediately loaded implants placed in postextraction sockets and healed sites. Over a 2-year period, all patients presenting with partial or complete edentulism of the maxilla and/or mandible (healed site group, at least 4 months of healing after tooth extraction) or in need of replacement of nonrecoverable failing teeth (postextraction group) were considered for inclusion in this study. Tapered implants featuring a nanostructured calcium-incorporated surface were placed and loaded immediately. The prosthetic restorations comprised single crowns, fixed partial dentures, and fixed full arches. Primary outcomes were implant survival, stability, and complications. Implant stability was assessed at placement and at each follow-up evaluation (1 week, 3 months, and 1 year after placement): implants with an insertion torque (IT) <45 N·cm and/or with an implant stability quotient (ISQ) <70 were considered failed for immediate loading. A statistical analysis was performed. Thirty implants were placed in postextraction sockets of 17 patients, and 32 implants were placed in healed sites of 22 patients. There were no statistically significant differences in ISQ values between the 2 groups, at each assessment. In total, 60 implants (96.8%) had an IT ≥45 and an ISQ ≥70 at placement and at each follow-up control: all these implants were successfully loaded. Only 2 implants (1 in a postextraction socket and 1 in a healed site, 3.2%) could not achieve an IT ≥45 N·cm and/or an ISQ ≥70 at placement or over time: accordingly, these were considered failed for stability, as they could not be subjected to immediate loading. One of these 2 implants, in a healed site of a posterior maxilla, had to be removed, yielding an overall 1-year implant survival rate of 98.4%. No complications were reported. No significant differences were reported between the 2 groups with respect to implant failures and complications. Immediately loaded implants placed in postextraction sockets and healed sites had similar high survival and stability, with no reported complications. Further long-term studies on larger samples of patients are needed to confirm these results.

  14. The high cost of clinical negligence litigation in the NHS.

    PubMed

    Tingle, John

    2017-03-09

    John Tingle, Reader in Health Law at Nottingham Trent University, discusses a consultation document from the Department of Health on introducing fixed recoverable costs in lower-value clinical negligence claims.

  15. SU-F-BRD-05: Dosimetric Comparison of Protocol-Based SBRT Lung Treatment Modalities: Statistically Significant VMAT Advantages Over Fixed- Beam IMRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Best, R; Harrell, A; Geesey, C

    2014-06-15

    Purpose: The purpose of this study is to inter-compare and find statistically significant differences between flattened field fixed-beam (FB) IMRT with flattening-filter free (FFF) volumetric modulated arc therapy (VMAT) for stereotactic body radiation therapy SBRT. Methods: SBRT plans using FB IMRT and FFF VMAT were generated for fifteen SBRT lung patients using 6 MV beams. For each patient, both IMRT and VMAT plans were created for comparison. Plans were generated utilizing RTOG 0915 (peripheral, 10 patients) and RTOG 0813 (medial, 5 patients) lung protocols. Target dose, critical structure dose, and treatment time were compared and tested for statistical significance. Parametersmore » of interest included prescription isodose surface coverage, target dose heterogeneity, high dose spillage (location and volume), low dose spillage (location and volume), lung dose spillage, and critical structure maximum- and volumetric-dose limits. Results: For all criteria, we found equivalent or higher conformality with VMAT plans as well as reduced critical structure doses. Several differences passed a Student's t-test of significance: VMAT reduced the high dose spillage, evaluated with conformality index (CI), by an average of 9.4%±15.1% (p=0.030) compared to IMRT. VMAT plans reduced the lung volume receiving 20 Gy by 16.2%±15.0% (p=0.016) compared with IMRT. For the RTOG 0915 peripheral lesions, the volumes of lung receiving 12.4 Gy and 11.6 Gy were reduced by 27.0%±13.8% and 27.5%±12.6% (for both, p<0.001) in VMAT plans. Of the 26 protocol pass/fail criteria, VMAT plans were able to achieve an average of 0.2±0.7 (p=0.026) more constraints than the IMRT plans. Conclusions: FFF VMAT has dosimetric advantages over fixed beam IMRT for lung SBRT. Significant advantages included increased dose conformity, and reduced organs-at-risk doses. The overall improvements in terms of protocol pass/fail criteria were more modest and will require more patient data to establish difference trends of more statistical significance.« less

  16. Self-organizing radial basis function networks for adaptive flight control and aircraft engine state estimation

    NASA Astrophysics Data System (ADS)

    Shankar, Praveen

    The performance of nonlinear control algorithms such as feedback linearization and dynamic inversion is heavily dependent on the fidelity of the dynamic model being inverted. Incomplete or incorrect knowledge of the dynamics results in reduced performance and may lead to instability. Augmenting the baseline controller with approximators which utilize a parametrization structure that is adapted online reduces the effect of this error between the design model and actual dynamics. However, currently existing parameterizations employ a fixed set of basis functions that do not guarantee arbitrary tracking error performance. To address this problem, we develop a self-organizing parametrization structure that is proven to be stable and can guarantee arbitrary tracking error performance. The training algorithm to grow the network and adapt the parameters is derived from Lyapunov theory. In addition to growing the network of basis functions, a pruning strategy is incorporated to keep the size of the network as small as possible. This algorithm is implemented on a high performance flight vehicle such as F-15 military aircraft. The baseline dynamic inversion controller is augmented with a Self-Organizing Radial Basis Function Network (SORBFN) to minimize the effect of the inversion error which may occur due to imperfect modeling, approximate inversion or sudden changes in aircraft dynamics. The dynamic inversion controller is simulated for different situations including control surface failures, modeling errors and external disturbances with and without the adaptive network. A performance measure of maximum tracking error is specified for both the controllers a priori. Excellent tracking error minimization to a pre-specified level using the adaptive approximation based controller was achieved while the baseline dynamic inversion controller failed to meet this performance specification. The performance of the SORBFN based controller is also compared to a fixed RBF network based adaptive controller. While the fixed RBF network based controller which is tuned to compensate for control surface failures fails to achieve the same performance under modeling uncertainty and disturbances, the SORBFN is able to achieve good tracking convergence under all error conditions.

  17. Control of the estrous cycle to improve fertility for fixed-time artificial insemination in beef cattle: a review.

    PubMed

    Lamb, G C; Dahlen, C R; Larson, J E; Marquezini, G; Stevenson, J S

    2010-04-01

    Early estrus-synchronization protocols focused on regressing the corpus luteum (CL) with an injection of PGF(2alpha) followed by detection of estrus or involved the use of exogenous progestins that prevent estrus from occurring. Later, protocols combining the use of PGF(2alpha) and exogenous progestins were developed. Gonadotropin-releasing hormone was utilized to control follicular waves, synchronize ovulation, or to luteinize large dominant follicles. Our research aimed to develop reliable protocols that 1) relied solely on fixed-timed AI (TAI); 2) required a maximum of 3 animal handlings, and 3) were successful in estrous-cycling and noncycling females. In cows, insertion of an intravaginal progesterone insert during the 7-d interval between the initial GnRH and PGF(2alpha) injections enhanced pregnancy rates by 9 to 10%. In a multi-location study, a TAI protocol yielded pregnancy rates similar to a protocol involving detection of estrus plus a fixed-time clean-up AI for females not detected in estrus (54 vs. 58%, respectively, for cows and 53 vs. 57%, respectively, for heifers). Initiation of estrous cycles in noncycling cows is likely the primary manner in which beef producers may improve fertility in response to estrus synchronization and TAI protocols. Treatment of noncycling females with progesterone and GnRH increases the percentage of cycling females and improves fertility to a TAI, but inducing cyclicity with hCG failed to enhance fertility in TAI protocols. Supplementing progesterone after TAI failed to increase pregnancy rates in beef cattle. In contrast, administration of hCG 7 d after TAI induced an accessory CL, increased progesterone, and tended to enhance pregnancy rates. Development of TAI protocols that reduce the hassle factors associated with ovulation synchronization and AI provide cattle producers efficient and effective tools for capturing selective genetic traits of economic consequences. Location variables, however, which may include differences in pasture and diet, breed composition, body condition, postpartum interval, climate, and geographic location, affect the success of TAI protocols.

  18. Beta-tricalcium phosphate plugs for press-fit fixation in ACL reconstruction--a mechanical analysis in bovine bone.

    PubMed

    Mayr, Hermann O; Hube, Robert; Bernstein, Anke; Seibt, Alexander B; Hein, Werner; von Eisenhart-Rothe, Ruediger

    2007-06-01

    The goal of this study was to test fixation properties of microporous pure beta-tricalcium phosphate (TCP) plugs (porosity 40%) for press-fit fixation of the ACL graft using patellar tendons with and without bone blocks. We set out to establish whether it is possible, in this way, to obtain results comparable with those of interference screw fixation of bone-tendon-bone (BTB) grafts in terms of cyclic loading and load-to-failure. In a bovine model 30 ACL grafts were fixed in tibial drill holes, divided into three groups: 10 BTB grafts fixed with TCP press-fit plugs (7x25 mm), 10 pure patellar tendon grafts with TCP press-fit plugs (7x25 mm), and 10 BTB grafts with metal interference screws (7x25 mm). All grafts were tested by cyclic loading (50-200 N) and loaded until failure in a tensiometer. Under cyclic loading one interference screw fixation failed. None of the TCP plug fixations failed. After 1500 cycles the displacement of the graft in the drill hole for BTB fixed with screws was 3.6+/-7.8 mm, for BTB/TCP plugs 1.6+/-3.4 mm, and for the pure tendon/TCP grafts 1.4+/-0.4 mm. Regarding cyclic loading the pure tendon/TCP system was significantly superior to BTB (p=0.007). The load-to-failure for the BTB/interference screw group was 908+/-539 N with a stiffness of 94+/-36 N/mm, 936+/-245 N for the BTB/TCP cylinder group with a stiffness of 98+/-12 N/mm, and 673+/-159 N for the pure tendon/TCP group with a stiffness of 117+/-9 N/mm. In terms of pull-out load the BTB/TCP system was significantly better than the pure tendon/TCP group (p=0.011). However, pure tendon/TCP grafts achieved significantly greater stiffness (p=0.002) than the BTB system. Press-fit fixation with microporous pure beta-TCP plugs of BTB grafts or patellar tendon grafts without bone blocks for ACL reconstruction leads to primary stability comparable with that achieved by fixation with metal interference screws in case of BTB grafts.

  19. Technique for fixing a temporalis muscle using a titanium plate to the implanted hydroxyapatite ceramics for bone defects.

    PubMed

    Ono, I; Tateshita, T; Sasaki, T; Matsumoto, M; Kodama, N

    2001-05-01

    We devised a technique to fix the temporalis muscle to the transplanted hydroxyapatite implant by using a titanium plate, which is fixed to the hydroxyapatite ceramic implant by screws and achieves good clinical results. The size, shape, and curvature of the hydroxyapatite ceramic implants were determined according to full-scale models fabricated using the laser lithographic modeling method from computed tomography data. A titanium plate was then fixed with screws on the implant before implantation, and then the temporalis muscle was refixed to the holes at both ends of the plate. The application of this technique reduced the hospitalization time and achieved good results esthetically.

  20. Comparison of Expandable and Fixed Interbody Cages in a Human Cadaver Corpectomy Model: Fatigue Characteristics.

    PubMed

    Pekmezci, Murat; Tang, Jessica A; Cheng, Liu; Modak, Ashin; McClellan, Robert T; Buckley, Jenni M; Ames, Christopher P

    2016-11-01

    In vitro cadaver biomechanics study. The goal of this study is to compare the in situ fatigue life of expandable versus fixed interbody cage designs. Expandable cages are becoming more popular, in large part, due to their versatility; however, subsidence and catastrophic failure remain a concern. This in vitro analysis investigates the fatigue life of expandable and fixed interbody cages in a single level human cadaver corpectomy model by evaluating modes of subsidence of expandable and fixed cages as well as change in stiffness of the constructs with cyclic loading. Nineteen specimens from 10 human thoracolumbar spines (T10-L2, L3-L5) were biomechanically evaluated after a single level corpectomy that was reconstructed with an expandable or fixed cage and anterior dual rod instrumentation. All specimens underwent 98 K cycles to simulate 3 months of postoperative weight bearing. In addition, a third group with hyperlordotic cages was used to simulate catastrophic failure that is observed in clinical practice. Three fixed and 2 expandable cages withstood the cyclic loading despite perfect sagittal and coronal plane fitting of the endcaps. The majority of the constructs settled in after initial subsidence. The catastrophic failures that were observed in clinical practice could not be reproduced with hyperlordotic cages. However, all cages in this group subsided, and 60% resulted in endplate fractures during deployment of the cage. Despite greater surface contact area, expandable cages have a trend for higher subsidence rates when compared with fixed cages. When there is edge loading as in the hyperlordotic cage scenario, there is a higher risk of subsidence and intraoperative fracture during deployment of expandable cages.

  1. Reachability bounds for chemical reaction networks and strand displacement systems.

    PubMed

    Condon, Anne; Kirkpatrick, Bonnie; Maňuch, Ján

    2014-01-01

    Chemical reaction networks (CRNs) and DNA strand displacement systems (DSDs) are widely-studied and useful models of molecular programming. However, in order for some DSDs in the literature to behave in an expected manner, the initial number of copies of some reagents is required to be fixed. In this paper we show that, when multiple copies of all initial molecules are present, general types of CRNs and DSDs fail to work correctly if the length of the shortest sequence of reactions needed to produce any given molecule exceeds a threshold that grows polynomially with attributes of the system.

  2. Multipolar pacing by cardiac resynchronization therapy with a defibrillators treatment in type 2 diabetes mellitus failing heart patients: impact on responders rate, and clinical outcomes.

    PubMed

    Sardu, Celestino; Barbieri, Michelangela; Santamaria, Matteo; Giordano, Valerio; Sacra, Cosimo; Paolisso, Pasquale; Spirito, Alessandro; Marfella, Raffaele; Paolisso, Giuseppe; Rizzo, Maria Rosaria

    2017-06-09

    Type 2 diabetes mellitus (T2DM) is a multi factorial disease, affecting clinical outcomes in failing heart patients treated by cardiac resynchronization therapy with a defibrillator (CRT-d). One hundred and ninety-five T2DM patients received a CRT-d treatment. Randomly the study population received a CRT-d via multipolar left ventricle (LV) lead pacing (n 99, multipolar group), vs a CRT-d via bipolar LV pacing (n 96, bipolar group). These patients were followed by clinical, and instrumental assessment, and telemetric device control at follow up. In this study we evaluated, in a population of failing heart T2DM patients, cardiac deaths, all cause deaths, arrhythmic events, CRT-d responders rate, hospitalizations for HF worsening, phrenic nerve stimulation (PNS), and LV catheter dislodgment events (and re-intervention for LV catheter re-positioning), comparing multipolar CRT-d vs bipolar CRT-d group of patients at follow up. At follow up there was a statistical significant difference about atrial arrhythmic events [7 (7%) vs 16 (16.7%), p value 0.019], hospitalizations for HF worsening [15 (15.2% vs 24 (25%), p value 0.046], LV catheter dislodgments [1 (1%) vs 9 (9.4%), p value 0018], PNS [5 (5%) vs 18 (18.7%), p value 0.007], and LV re-positioning [1 (1%) vs 9 (9.4%), p value 0.018], comparing multipolar CRT-d vs bipolar CRT-d group of patients. Multipolar pacing was an independent predictor of all these events. CRT-d pacing via multipolar LV lead vs bipolar LV lead may reduce arrhythmic burden, hospitalization rate, PNS, LV catheters dislodgments, and re-interventions in T2DM failing heart patients. Clinical trial number NCT03095196.

  3. Alzheimer’s Disease Drug Development in 2008 and Beyond: Problems and Opportunities

    PubMed Central

    Becker, Robert E.; Greig, Nigel H.

    2008-01-01

    Recently, a number of Alzheimer’s disease (AD) multi-center clinical trials (CT) have failed to provide statistically significant evidence of drug efficacy. To test for possible design or execution flaws we analyzed in detail CTs for two failed drugs that were strongly supported by preclinical evidence and by proven CT AD efficacy for other drugs in their class. Studies of the failed commercial trials suggest that methodological flaws may contribute to the failures and that these flaws lurk within current drug development practices ready to impact other AD drug development [1]. To identify and counter risks we considered the relevance to AD drug development of the following factors: (1) effective dosing of the drug product, (2) reliable evaluations of research subjects, (3) effective implementation of quality controls over data at research sites, (4) resources for practitioners to effectively use CT results in patient care, (5) effective disease modeling, (6) effective research designs. New drugs currently under development for AD address a variety of specific mechanistic targets. Mechanistic targets provide AD drug development opportunities to escape from many of the factors that currently undermine AD clinical pharmacology, especially the problems of inaccuracy and imprecision associated with using rated outcomes. In this paper we conclude that many of the current problems encountered in AD drug development can be avoided by changing practices. Current problems with human errors in clinical trials make it difficult to differentiate drugs that fail to evidence efficacy from apparent failures due to Type II errors. This uncertainty and the lack of publication of negative data impede researchers’ abilities to improve methodologies in clinical pharmacology and to develop a sound body of knowledge about drug actions. We consider the identification of molecular targets as offering further opportunities for overcoming current failures in drug development. PMID:18690832

  4. Mobile vs. fixed bearing unicondylar knee arthroplasty: A randomized study on short term clinical outcomes and knee kinematics.

    PubMed

    Li, Ming G; Yao, Felix; Joss, Brendan; Ioppolo, James; Nivbrant, Bo; Wood, David

    2006-10-01

    The literature contains limited yet controversial information regarding whether a fixed or a mobile bearing implant should be used in unicompartmental knee arthroplasty (UKA). This randomized study was to further document the performance and comparison of the two designs. Fifty-six knees in 48 patients (mean age of 72 years) undergoing medial UKA were randomized into a fixed bearing (Miller/Galante) or a mobile bearing (Oxford) UKA. The 2 year clinical outcomes (clinical scores), radiographic findings, and weight bearing knee kinematics (assessed using RSA) were compared between the two groups. The mobile bearing knees displayed a larger and an incrementally increased tibial internal rotation (4.3 degrees, 7.6 degrees, 9.5 degrees vs. 3.0 degrees, 3.0 degrees, 4.2 degrees respectively at 30 degrees, 60 degrees, 90 degrees of knee flexion) compared to the fixed ones. The medial femoral condyle in the mobile bearing knees remained 2 mm from the initial position vs. a 4.2 mm anterior translation in the fixed bearing knees during knee flexion. The contact point in the mobile bearing implant moved 2 mm posteriorly vs. a 6 mm anterior movement in the other group. The mobile bearing knees had a lower incidence of radiolucency at the bone implant interface (8% vs. 37%, p < 0.05). The incidence of lateral compartment OA and progression of OA at patello-femoral joint were equal. No differences were found regarding Knee Society Scores, WOMAC, and SF-36 scores (p > 0.05). This study indicates that mobile bearing knees had a better kinematics, a lower incidence of radiolucency but not yet a better knee function at 2 years.

  5. Clinical Utility of an Automated Instrument for Gram Staining Single Slides ▿

    PubMed Central

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-01-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis. PMID:20410348

  6. Government agencies soften stance on what constitutes price fixing.

    PubMed

    Ettinger, D A; Lasser, M L

    1997-02-01

    The Federal Trade Commission and the Department of Justice have modified their views on what constitutes price fixing by integrated delivery systems. Recently released enforcement policy statements indicate that joint agreements on price between competing providers will not necessarily constitute price fixing, even without risk sharing, if the system is sufficiently integrated. The enforcement policy statements indicate that if integration arises from the combined efforts of previously competing providers, involves improvements in clinical efficiency or quality, and demonstrates no anticompetitive intent, it will be sufficient to withstand Federal scrutiny.

  7. Influence of Previous Failed Antispasticity Therapy on the Efficacy and Tolerability of THC:CBD Oromucosal Spray for Multiple Sclerosis Spasticity.

    PubMed

    Haupts, Michael; Vila, Carlos; Jonas, Anna; Witte, Kerstin; Álvarez-Ossorio, Lourdes

    2016-01-01

    Sativex® (THC:CBD oromucosal spray) is indicated as add-on treatment for patients with moderate to severe multiple sclerosis (MS) spasticity. We aimed to determine whether antispasticity treatment history influenced the efficacy and safety of add-on THC:CBD oromucosal spray in MS spasticity patients. Post hoc analysis of an enriched-design clinical trial of THC:CBD oromucosal spray versus placebo, using records of patients under previous and current ineffective antispasticity therapies. Subgroups were patients with at least 1 failed therapy attempt with either baclofen or tizanidine (Group 1) or at least 2 failed therapy attempts with both baclofen and tizanidine (Group 2). Of 241 patients in the intent-to-treat population, 162 and 57 patients met the criteria for Groups 1 and 2, respectively. In all groups, response on the spasticity 0-10 Numerical Rating Scale was significantly greater with THC:CBD oromucosal spray versus placebo, for minimal clinically important difference (MCID ≥18% improvement vs. baseline) and clinically important difference (CID, ≥30% improvement vs. baseline). THC:CBD oromucosal spray improved spasticity-related symptoms such as sleep quality and timed 10-meter walk independent of the number of prior failed therapy attempts. Tolerability was not influenced by pre-treatment history. THC:CBD oromucosal spray provided consistent relief with good tolerability in MS spasticity patients irrespective of their antispasticity pre-treatment history. © 2016 S. Karger AG, Basel.

  8. Clinical outcome and surgical strategies for late post-traumatic kyphosis after failed thoracolumbar fracture operation: Case report and literature review.

    PubMed

    Li, Suyun; Li, Zhi; Hua, Wenbin; Wang, Kun; Li, Shuai; Zhang, Yunkun; Ye, Zhewei; Shao, Zengwu; Wu, Xinghuo; Yang, Cao

    2017-12-01

    Thoracic-lumbar vertebral fracture is very common in clinic, and late post-traumatic kyphosis is the main cause closely related to the patients' life quality, which has evocated extensive concern for the surgical treatment of the disease. This study aimed to analyze the clinical outcomes and surgical strategies for late post-traumatic kyphosis after failed thoracolumbar fracture operation. All patients presented back pain with kyphotic apex vertebrae between T12 and L3. According to Frankel classification grading system, among them, 3 patients were classified as grade D, with the ability to live independently. A systematic review of 12 case series of post-traumatic kyphosis after failed thoracolumbar fracture operation was involved. Wedge osteotomy was performed as indicated-posterior closing osteotomy correction in 5 patients and anterior open-posterior close correction in 7 patients.Postoperatively, thoracolumbar x-rays were obtained to evaluate the correction of kyphotic deformity, visual analog scales (VAS) and Frankel grading system were used for access the clinical outcomes. All the patients were followed up, with the average period of 38.5 months (range 24-56 months). The Kyphotic Cobb angle was improved from preoperative (28.65 ± 11.41) to postoperative (1.14 ± 2.79), with the correction rate of 96.02%. There was 1 case of intraoperative dural tear, without complications such as death, neurological injury, and wound infection. According to Frankel grading system, no patient suffered deteriorated neurological symptoms after surgery, and 2 patients (2/3) experienced significant relief after surgery. The main VAS score of back pain was improved from preoperative (4.41 ± 1.08) to postoperative (1.5 ± 0.91) at final follow-up, with an improvement rate of 65.89%. Surgical treatment of late post-traumatic kyphosis after failed thoracolumbar fracture operation can obtain good radiologic and clinical outcomes by kyphosis correction, decompression, and posterior stability.

  9. Clinical outcome and surgical strategies for late post-traumatic kyphosis after failed thoracolumbar fracture operation

    PubMed Central

    Li, Suyun; Li, Zhi; Hua, Wenbin; Wang, Kun; Li, Shuai; Zhang, Yunkun; Ye, Zhewei; Shao, Zengwu; Wu, Xinghuo; Yang, Cao

    2017-01-01

    Abstract Rationale: Thoracic-lumbar vertebral fracture is very common in clinic, and late post-traumatic kyphosis is the main cause closely related to the patients’ life quality, which has evocated extensive concern for the surgical treatment of the disease. This study aimed to analyze the clinical outcomes and surgical strategies for late post-traumatic kyphosis after failed thoracolumbar fracture operation. Patient concerns: All patients presented back pain with kyphotic apex vertebrae between T12 and L3. According to Frankel classification grading system, among them, 3 patients were classified as grade D, with the ability to live independently. Diagnoses: A systematic review of 12 case series of post-traumatic kyphosis after failed thoracolumbar fracture operation was involved. Interventions: Wedge osteotomy was performed as indicated—posterior closing osteotomy correction in 5 patients and anterior open-posterior close correction in 7 patients.Postoperatively, thoracolumbar x-rays were obtained to evaluate the correction of kyphotic deformity, visual analog scales (VAS) and Frankel grading system were used for access the clinical outcomes. Outcomes: All the patients were followed up, with the average period of 38.5 months (range 24–56 months). The Kyphotic Cobb angle was improved from preoperative (28.65 ± 11.41) to postoperative (1.14 ± 2.79), with the correction rate of 96.02%. There was 1 case of intraoperative dural tear, without complications such as death, neurological injury, and wound infection. According to Frankel grading system, no patient suffered deteriorated neurological symptoms after surgery, and 2 patients (2/3) experienced significant relief after surgery. The main VAS score of back pain was improved from preoperative (4.41 ± 1.08) to postoperative (1.5 ± 0.91) at final follow-up, with an improvement rate of 65.89%. Lessons: Surgical treatment of late post-traumatic kyphosis after failed thoracolumbar fracture operation can obtain good radiologic and clinical outcomes by kyphosis correction, decompression, and posterior stability. PMID:29245233

  10. Failing to Fix What is Found: Risk Accommodation in the Oil and Gas Industry.

    PubMed

    Stackhouse, Madelynn R D; Stewart, Robert

    2017-01-01

    The present program of research synthesizes the findings from three studies in line with two goals. First, the present research explores how the oil and gas industry is performing at risk mitigation in terms of finding and fixing errors when they occur. Second, the present research explores what factors in the work environment relate to a risk-accommodating environment. Study 1 presents a descriptive evaluation of high-consequence incidents at 34 oil and gas companies over a 12-month period (N = 873), especially in terms of those companies' effectiveness at investigating and fixing errors. The analysis found that most investigations were fair in terms of quality (mean = 75.50%), with a smaller proportion that were weak (mean = 11.40%) or strong (mean = 13.24%). Furthermore, most companies took at least one corrective action for high-consequence incidents, but few of these corrective actions were confirmed as having been completed (mean = 13.77%). In fact, most corrective actions were secondary interim administrative controls (e.g., having a safety meeting) rather than fair or strong controls (e.g., training, engineering elimination). Study 2a found that several environmental factors explain the 56.41% variance in safety, including management's disengagement from safety concerns, finding and fixing errors, safety management system effectiveness, training, employee safety, procedures, and a production-over-safety culture. Qualitative results from Study 2b suggest that a compliance-based culture of adhering to liability concerns, out-group blame, and a production-over-safety orientation may all impede safety effectiveness. © 2016 Society for Risk Analysis.

  11. Songbird - AN Innovative Uas Combining the Advantages of Fixed Wing and Multi Rotor Uas

    NASA Astrophysics Data System (ADS)

    Thamm, F.-P.; Brieger, N.; Neitzke, K.-P.; Meyer, M.; Jansen, R.; Mönninghof, M.

    2015-08-01

    This paper describes a family of innovative fixed wing UAS with can vertical take off and land - the SONGBIRD family. With nominal payloads starting from 0.5 kg they can take off and land safely like a multi-rotor UAV, removing the need for an airstrip for the critical phases of operation. A specially designed flight controller allows stable flight at every point of the transition phase between VTOL and fixed wing mode. Because of this smooth process with a all time stable flight, very expensive payload like hyperspectral sensors or advanced optical cameras can be used. Due to their design all airplanes of the SONGBIRD family have excellent horizontal flight properties, a maximum speed of over 110 km/h, good gliding properties and long flight times of up to 1 h. Missions were flown in wind speeds up to 18 m/s. At every time of the flight it is possible to interrupt the mission and hover over a point of interest for detail investigations. The complete flight, including take-off and landing can be performed by autopilot. Designed for daily use in professional environments, SONGBIRDs are built out of glass-fibre and carbon composites for a long service life. For safe operations comprehensive security features are implemented, for example redundant flight controllers and sensors, advanced power management system and mature fail safe procedures. The aircraft can be dismantled into small parts for transportation. SONGBIRDS are available for different pay loads, from 500 g to 2 kg. The SONGBIRD family are interesting tools combining the advantages of multi-copter and fixed wing UAS.

  12. [Treatment of calcaneal avulsion fractures with twinfix suture anchors fixation].

    PubMed

    Zhao, Bin-xiu; Wang, Kun-zheng; Wang, Chun-sheng; Xie, Yue; Dai, Zhi-tang; Liu, Gang; Liu, Wei-dong

    2011-06-01

    For the calcaneal avulsion fracture, the current method is more commonly used screws or Kirschner wire to fix fracture fragment. This article intended to explore the feasibility and clinical efficacy for the treatment of avulsion fractures with TwinFix suture anchors. From July 2007 to November 2010, 21 patients were reviewed, including 15 males and 6 females, ranging in age from 49 to 65 years,with a mean of 58.7 years. Twelve patients had nodules in the right heel and 9 patients had nodules in the left heel. All the patients had closed fractures. The typical preoperative symptoms of the patients included pain in the upper heel and weak in heel lift. Body examination results: palpable sense of bone rubbing in the back of the heel, and swelling in the heel. Surgery treatment with TwinFix suture anchors performed as follows : to fix TwinFix suture anchors into the calcaneal body, then to drill the fracture block, to make the double strand suture through the fracture holes, to knot the suture eachother to fix the block, and to use stitch to fix the remaining suture in the Achilles tendon in order to improve the block fixation. The criteria of the AOFAS Foot and Ankle Surgery by the United States Association of ankle-rear foot functional recovery was used to evaluate the Achilles tendon. Total average score was (95.5 +/- 3.12) points, including pain items of(38.5 +/- 2.18) points,the average score of functional items of (49.5 +/- 3.09) points,and power lines of 10 points in all patients. Twenty-one patients got an excellent result, 16 good and 5 poor. The methods of treatment for the calcaneal avulsion fractures with TwinFix suture anchors is a simple operation, and have excellent clinical effect, which is worthy of promotion.

  13. Time-to-isolation guided titration of freeze duration in 3rd generation short-tip cryoballoon pulmonary vein isolation - Comparable clinical outcome and shorter procedure duration.

    PubMed

    Pott, Alexander; Kraft, Christoph; Stephan, Tilman; Petscher, Kerstin; Rottbauer, Wolfgang; Dahme, Tillman

    2018-03-15

    The optimal freeze duration in cryoballoon pulmonary vein isolation (PVI) is unknown. The 3rd generation cryoballoon facilitates observation of the time-to-isolation (TTI) and thereby enables individualized cryoenergy titration. To evaluate the efficacy of an individualized freeze duration we compared the clinical outcome of patients treated with a TTI-guided ablation protocol to the outcome of patients treated with a fixed ablation protocol. We compared 100 patients treated with the 3rd generation cryoballoon applying a TTI-based protocol (TTI group) to 100 patients treated by a fixed freeze protocol (fixed group). In the fixed group a 240s freeze cycle was followed by a 240s bonus freeze after acute PV isolation. In the TTI group freeze duration was 180s if TTI was ≥30s and reduced to only 120s, if TTI was <30s. In case of a TTI >60s a 180s bonus freeze was applied. Freedom from atrial arrhythmia recurrence off class I/III antiarrhythmic drugs after one year was not different between the TTI group (73.6%) and the fixed group (75.7%; p=0.75). Mean procedure duration was 85.8±27.3min in the TTI group compared to 115.7±27.1min in the fixed group (p<0.001). Mean fluoroscopy time was 17.5±6.6min in the TTI group and 22.5±9.8min in the fixed group (p<0.001). TTI-guided cryoenergy titration leads to reduced procedure duration and fluoroscopy time and appears to be as effective as a fixed ablation strategy. A single 2-minute freeze seems to be sufficient in case of short TTI. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Continuous prophylaxis with recombinant factor IX Fc fusion protein and conventional recombinant factor IX products: comparisons of efficacy and weekly factor consumption.

    PubMed

    Iorio, Alfonso; Krishnan, Sangeeta; Myrén, Karl-Johan; Lethagen, Stefan; McCormick, Nora; Yermakov, Sander; Karner, Paul

    2017-04-01

    Continuous prophylaxis for patients with hemophilia B requires frequent injections that are burdensome and that may lead to suboptimal adherence and outcomes. Hence, therapies requiring less-frequent injections are needed. In the absence of head-to-head comparisons, this study compared the first extended-half-life-recombinant factor IX (rFIX) product-recombinant factor IX Fc fusion protein (rFIXFc)-with conventional rFIX products based on annualized bleed rates (ABRs) and factor consumption reported in studies of continuous prophylaxis. This study compared ABRs and weekly factor consumption rates in clinical studies of continuous prophylaxis treatment with rFIXFc and conventional rFIX products (identified by systematic literature review) in previously-treated adolescents and adults with moderate-to-severe hemophilia B. Meta-analysis was used to pool ABRs reported for conventional rFIX products for comparison. Comparisons of weekly factor consumption were based on the mean, reported or estimated from the mean dose per injection. Five conventional rFIX studies (injections 1 to >3 times/week) met the criteria for comparison with once-weekly rFIXFc reported by the B-LONG study. The pooled mean ABR for conventional rFIX was slightly higher than but comparable to rFIXFc (difference=0.71; p = 0.210). Weekly factor consumption was significantly lower with rFIXFc than in conventional rFIX studies (difference in means = 42.8-74.5 IU/kg/week [93-161%], p < 0.001). Comparisons of clinical study results suggest weekly injections with rFIXFc result in similar bleeding rates and significantly lower weekly factor consumption compared with more-frequently-injected conventional rFIX products. The real-world effectiveness of rFIXFc may be higher based on results from a model of the impact of simulated differences in adherence.

  15. Intraocular pressure decrease with preservative-free fixed and unfixed combination of tafluprost and timolol in pseudoexfoliative glaucoma.

    PubMed

    Holló, Gábor; Ropo, Auli

    2015-01-01

    We investigated the intraocular pressure (IOP) lowering efficacy of preservative-free fixed and non-fixed combination of tafluprost 0.0015% and timolol 0.5% in pseudoexfoliative glaucoma (XFG). A per protocol worse eye analysis was made on all XFG patients who participated in a recent 6 month, prospective, randomized, double-masked, parallel group, multicenter phase III study. The mean time-wise IOP decreased by 8.62 to 10.25 mmHg (31.8 to 36.7%) in the fixed dose combination arm (15 patients) and by 5.38 to 11.35 mmHg (21.3 to 41.2%) in the non-fixed combination arm (13 patients), respectively (p < 0.001 for all comparisons). The results show that a preservative-free fixed dose combination of tafluprost and timolol provides a clinically significant IOP reduction in XFG, and may offer an advantage for the XFG patients with dry eye, due to its preservative-free nature.

  16. Reduced bleeding events with subcutaneous administration of recombinant human factor IX in immune-tolerant hemophilia B dogs.

    PubMed

    Russell, Karen E; Olsen, Eva H N; Raymer, Robin A; Merricks, Elizabeth P; Bellinger, Dwight A; Read, Marjorie S; Rup, Bonita J; Keith, James C; McCarthy, Kyle P; Schaub, Robert G; Nichols, Timothy C

    2003-12-15

    Intravenous administration of recombinant human factor IX (rhFIX) acutely corrects the coagulopathy in hemophilia B dogs. To date, 20 of 20 dogs developed inhibitory antibodies to the xenoprotein, making it impossible to determine if new human FIX products, formulations, or methods of chronic administration can reduce bleeding frequency. Our goal was to determine whether hemophilia B dogs rendered tolerant to rhFIX would have reduced bleeding episodes while on sustained prophylactic rhFIX administered subcutaneously. Reproducible methods were developed for inducing tolerance to rhFIX in this strain of hemophilia B dogs, resulting in a significant reduction in the development of inhibitors relative to historical controls (5 of 12 versus 20 or 20, P <.001). The 7 of 12 tolerized hemophilia B dogs exhibited shortened whole blood clotting times (WBCTs), sustained detectable FIX antigen, undetectable Bethesda inhibitors, transient or no detectable antihuman FIX antibody titers by enzyme-linked immunosorbent assay (ELISA), and normal clearance of infused rhFIX. Tolerized hemophilia B dogs had 69% reduction in bleeding frequency in year 1 compared with nontolerized hemophilia B dogs (P =.0007). If proven safe in human clinical trials, subcutaneous rhFIX may provide an alternate approach to prophylactic therapy in selected patients with hemophilia B.

  17. [Particle disease. Is tribology a topic in revision surgery?].

    PubMed

    Elke, R

    2001-05-01

    To improve the longevity of endoprostheses, the main goal is to reduce wear. Polyethylene together with metal or ceramic is currently the most frequently used combination. Their clinical success is well documented in the literature. Many attempts to improve polyethylene in the past have failed. Materials successful in the laboratory have failed in clinical use. The most recent competitors of ultra-high molecular weight polyethylene (UHMWPE) are the highly cross-linked polyethylenes (HCLPE) and the hard-on-hard couplings such as metal-on-metal or ceramic-on-ceramic. Advantages and downsides regarding particle generation and higher standards of precision in positioning the components are discussed.

  18. A Second Opinion: A Case Narrative on Clinical Ethics Mediation.

    PubMed

    Weinstein, Michael S

    2015-01-01

    Contrasting traditional and common forms of ethics consultation with bioethics mediation, I describe the case of a "second opinion" consultation in the care of a patient with advanced cancer for whom treatment was futile. While the initial ethics consultation, performed by a colleague, led to a recommendation that some may deem ethical, the process failed to involve key stakeholders and failed to explore the underlying values and reasons for the opinions voiced by various stakeholders. The process of mediation ultimately led to creative solutions in which all stakeholders could reach consensus on a plan of care. Copyright 2015 The Journal of Clinical Ethics. All rights reserved.

  19. [Combination therapy in the medical treatment of glaucoma].

    PubMed

    Hommer, A

    2013-02-01

    A combination of antiglaucoma medications is indicated if monotherapy is not sufficient to achieve the predefined target pressure and/or in case of a progression of glaucomatous damage or conversion from ocular hypertension to glaucomatous optic neuropathy. Most recently many fixed combinations with two active compounds have become available for the medical treatment of glaucoma. Compared to non-fixed combinations, these drugs offer a much easier use for the patients. Fixed combinations have to be applied less frequently which may improve adherence. Furthermore, they most likely contain a lower amount of toxic preservatives compared to non-fixed combinations. And finally, fixed combinations may eliminate the risk of a "washout" of the first medication by using the second product of a non-fixed combination too soon after the first drop has been installed. This review aims to examine the most important aspects of IOP-lowering fixed and non-fixed combinations in glaucoma management with a clear focus on the results obtained with fixed combinations. In Germany, fixed combinations with the compositions dorzolamide/timolol (FCDT), brinzolamide/timolol (FCBRINT), latanoprost/timolol (FCLT), travoprost/timolol (FCTT), bimatoprost/timolol (FCBIMT), brimonidine/timolol (FCBT), pilocarpine/timolol (FCPT) and metipranolol/timolol (FCMT) are approved for the medical management of glaucoma and ocular hypertension. The results of clinical studies comparing fixed combinations with their active ingredients and with the corresponding non-fixed combinations will be discussed. Furthermore - if available - the results of direct comparisons of the efficacy and safety of different IOP-lowering fixed combinations are summarised. Georg Thieme Verlag KG Stuttgart · New York.

  20. Treating OCD: what to do when first-line therapies fail.

    PubMed

    Castle, David; Bosanac, Peter; Rossell, Susan

    2015-08-01

    To provide a clinically-focused review of the biological treatment of treatment-resistant obsessive compulsive disorder (OCD). There is a paucity of research on how to manage OCD patients who fail to respond adequately to first line therapies. High-dose selective serotonin reuptake inhibitors (SSRIs) and clomipramine have good evidence-based data. Combinations of SSRIs have little support in clinical trials, but the combination of SSRIs and clomipramine can be helpful: careful clinical and cardiac monitoring is required. Certain adjunctive antipsychotics have a reasonable evidence base in OCD, but their use also needs to be weighed against the potential side effect burden. In patients with substantial generalised anxiety symptoms, clonazepam is worth considering. Of the other augmenting strategies, memantine and ondansetron appear useful in some cases, and are well tolerated. Topiramate might ameliorate compulsions to some degree, but it is less well tolerated. If all these strategies, along with expert psychological therapy, fail, careful consideration should be given to deep brain stimulation (DBS), which has an emerging evidence base and which can result in dramatic benefits for some individuals. For some patients, gamma radiosurgery might also still have a place. © The Royal Australian and New Zealand College of Psychiatrists 2015.

  1. Prevention and treatment of white spot lesions during and after fixed orthodontic treatment: A systematic literature review.

    PubMed

    Lapenaite, Egle; Lopatiene, Kristina; Ragauskaite, Aira

    2016-01-01

    The aim of the study is to evaluate the effectiveness of fluoride and casein topical preparations in the prevention of white spot lesions during and after fixed orthodontic treatment. Information search for controlled studies on humans published in the English language between 2008 and 2013 was conducted in Medline via PubMed, ScienceDirect, and Oxford University Press: Oxford journals and The Cochrane Library, as well as the Web search Google Scholar. 177 articles were reviewed; eleven clinical studies fulfilled all inclusion criteria. In the clinical studies it was concluded that high-concentration fluoride supplements are effective in reducing white spot lesions. Results of the studies showed the same usefulness of fluoride varnish, MI Paste, and usual oral hygiene using 1100 ppm of fluoride toothpaste. Effect on the prevention and treatment of white spot lesions of oral hygiene with toothpaste containing 1450 ppm of fluoride in orthodontic patients was evaluated. The positive effect of casein phosphopeptide-amorphous calcium phosphate in white spot lesions treatment was found. Otherwise in some clinical studies use of casein derivates during fixed orthodontics for white spot lesions treatment was not effective. More clinical studies conducted during last five years yielded significantly positive results about the effectiveness of fluoride and caseine supplements in ameliorating white spot lesions during and after fixed orthodontic treatment. For a higher-risk patient group, additional supplements such as high-concentrated fluoride varnish, chewing sticks, or casein derivates, are required. A good oral hygiene regimen using high-fluoride toothpaste is as effective as fluoride or casein derivates in the prevention of new white spot lesions formation.

  2. Large-scale Clinical-grade Retroviral Vector Production in a Fixed-Bed Bioreactor

    PubMed Central

    Wang, Xiuyan; Olszewska, Malgorzata; Qu, Jinrong; Wasielewska, Teresa; Bartido, Shirley; Hermetet, Gregory; Sadelain, Michel

    2015-01-01

    The successful genetic engineering of patient T cells with γ-retroviral vectors expressing chimeric antigen receptors or T-cell receptors for phase II clinical trials and beyond requires the large-scale manufacture of high-titer vector stocks. The production of retroviral vectors from stable packaging cell lines using roller bottles or 10- to 40-layer cell factories is limited by a narrow harvest window, labor intensity, open-system operations, and the requirement for significant incubator space. To circumvent these shortcomings, we optimized the production of vector stocks in a disposable fixed-bed bioreactor using good manufacturing practice–grade packaging cell lines. High-titer vector stocks were harvested over 10 days, representing a much broader harvest window than the 3-day harvest afforded by cell factories. For PG13 and 293Vec packaging cells, the average vector titer and the vector stocks’ yield in the bioreactor were higher by 3.2- to 7.3-fold, and 5.6- to 13.1-fold, respectively, than those obtained in cell factories. The vector production was 10.4 and 18.6 times more efficient than in cell factories for PG13 and 293Vec cells, respectively. Furthermore, the vectors produced from the fixed-bed bioreactors passed the release test assays for clinical applications. Therefore, a single vector lot derived from 293Vec is suitable to transduce up to 500 patients cell doses in the context of large clinical trials using chimeric antigen receptors or T-cell receptors. These findings demonstrate for the first time that a robust fixed-bed bioreactor process can be used to produce γ-retroviral vector stocks scalable up to the commercialization phase. PMID:25751502

  3. Fixed functional appliances with multibracket appliances have no skeletal effect on the mandible: A systematic review and meta-analysis.

    PubMed

    Ishaq, Ramy Abdul Rahman; AlHammadi, Maged Sultan; Fayed, Mona M S; El-Ezz, Amr Abou; Mostafa, Yehya

    2016-05-01

    Our aim was to assess the skeletal mandibular changes (anteroposterior and vertical) in circumpubertal patients with fixed functional appliances installed on multibracket appliances compared with untreated patients. An open-ended electronic search of 4 databases (PubMed, Embase, Cochrane Library, and Web of Science) up to April 2014 was performed. Additional searches of relevant journals, reference lists of the retrieved articles, systematic reviews, and gray literature were performed. Specific inclusion and exclusion criteria were applied to identify relevant articles. Quality was evaluated using the Cochrane Collaboration risk of bias tool and the Newcastle-Ottawa scale for prospective controlled clinical trials. Meta-analyses were conducted with fixed and random effects models as appropriate. Statistical heterogeneity was also examined. Seven articles were included in the qualitative synthesis and 5 in the meta-analysis. The included randomized controlled trials were at high risk of bias, and the methodologic quality of the prospective controlled clinical trials was high. Based on assessment of the fixed functional appliance phase in isolation, no difference in mandibular anteroposterior positional changes (SNB angle) (standard mean difference, 0.11°; 95% CI, -0.28, 0.50) was found between the treated and control groups. The vertical dimension was not influenced by the fixed functional appliance treatment. There is little high-quality evidence concerning the relative influence of fixed functional appliances on skeletal and dentoalveolar changes. However, based on the limited evidence, it appears that they have little effect on the skeletal mandibular parameters. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  4. Clinically-relevant consecutive treatment with isoproterenol and adenosine protects the failing heart against ischaemia and reperfusion

    PubMed Central

    2014-01-01

    Background Consecutive treatment of normal heart with a high dose of isoproterenol and adenosine (Iso/Ade treatment), confers strong protection against ischaemia/reperfusion injury. In preparation for translation of this cardioprotective strategy into clinical practice during heart surgery, we further optimised conditions for this intervention using a clinically-relevant dose of Iso and determined its cardioprotective efficacy in hearts isolated from a model of surgically-induced heart failure. Methods Isolated Langendorff-perfused rat hearts were treated sequentially with 5 nM Iso and 30 μM Ade followed by different durations of washout prior to 30 min global ischaemia and 2 hrs reperfusion. Reperfusion injury was assessed by measuring haemodynamic function, lactate dehydrogenase (LDH) release and infarct size. Protein kinase C (PKC) activity and glycogen content were measured in hearts after the treatment. In a separate group of hearts, Cyclosporine A (CsA), a mitochondria permeability transition pore (MPTP) inhibitor, was added with Iso/Ade. Failing hearts extracted after 16 weeks of ligation of left coronary artery in 2 months old rats were also subjected to Iso/Ade treatment followed by ischaemia/reperfusion. Results Recovery of the rate pressure product (RPP) in Iso/Ade-treated hearts was significantly higher than in controls. Thus in Iso/Ade treated hearts with 5 nM Iso and no washout period, RPP recovery was 76.3 ± 6.9% of initial value vs. 28.5 ± 5.2% in controls. This was associated with a 3 fold reduction in LDH release irrespective to the duration of the washout period. Hearts with no washout of the drugs (Ade) had least infarct size, highest PKC activity and also showed reduced glycogen content. Cardioprotection with CsA was not additive to the effect of Iso/Ade treatment. Iso/Ade treatment conferred significant protection to failing hearts. Thus, RPP recovery in failing hearts subjected to the treatment was 69.0 ± 16.3% while in Control hearts 19.7 ± 4.0%. LDH release in these hearts was also 3 fold lower compared to Control. Conclusions Consecutive Iso/Ade treatment of normal heart can be effective at clinically-relevant doses and this effect appears to be mediated by glycogen depletion and inhibition of MPTP. This intervention protects clinically relevant failing heart model making it a promising candidate for clinical use. PMID:24885907

  5. Addition of a pontic to all-ceramic Turkom-Cera fixed partial denture restorations.

    PubMed

    Uludag, Bulent; Tokar, Emre; Polat, Serdar

    2013-04-01

    High-strength all-ceramic materials are commonly used in dentistry. When complications occur in an all-ceramic restoration, the restoration is usually replaced. This article describes the time-saving ability and cost-effectiveness of this novel technique for the addition of a pontic in two complicated clinical cases. Turkom-Cera(™) [Turkom-Ceramic (M) Sdn. Bhd.] with aluminum oxide (99.98%) is an all-ceramic system that offers the option of addition of a new pontic to the sintered framework. The new pontic was cut off from an alumina blank [Turkom-Ceramic (M) Sdn. Bhd.], moistened, and attached to the framework using alumina gel [Turkom-Ceramic (M) Sdn. Bhd.]. The framework was veneered with veneering porcelain (Vita VM 7; VITA Zahnfabrik). The two cases presented here involving the addition of a pontic to sintered framework were followed up for at least 1 year. No complication was detected or reported by the patients. Alumina- and zirconia-based ceramics are particularly suitable for for all-ceramic restorations in high-stress bearing areas. However, replacement of a failed all-ceramic restoration is not the most practical solution, considering both cost and tooth-related factors. This attractive feature of the Turkom-Cera allows the repair of a fractured ceramic coping or the addition of a new pontic to restorations.

  6. Lack of sex effect on brain activity during a visuomotor response task: functional MR imaging study.

    PubMed

    Mikhelashvili-Browner, Nina; Yousem, David M; Wu, Colin; Kraut, Michael A; Vaughan, Christina L; Oguz, Kader Karli; Calhoun, Vince D

    2003-03-01

    As more individuals are enrolled in clinical functional MR imaging (fMRI) studies, an understanding of how sex may influence fMRI-measured brain activation is critical. We used fixed- and random-effects models to study the influence of sex on fMRI patterns of brain activation during a simple visuomotor reaction time task in the group of 26 age-matched men and women. We evaluated the right visual, left visual, left primary motor, left supplementary motor, and left anterior cingulate areas. Volumes of activations did not significantly differ between the groups in any defined regions. Analysis of variance failed to show any significant correlations between sex and volumes of brain activation in any location studied. Mean percentage signal-intensity changes for all locations were similar between men and women. A two-way t test of brain activation in men and women, performed as a part of random-effects modeling, showed no significant difference at any site. Our results suggest that sex seems to have little influence on fMRI brain activation when we compared performance on the simple reaction-time task. The need to control for sex effects is not critical in the analysis of this task with fMRI.

  7. Present status of titanium removable dentures--a review of the literature.

    PubMed

    Ohkubo, C; Hanatani, S; Hosoi, T

    2008-09-01

    Although porcelain and zirconium oxide might be used for fixed partial dental prostheses instead of conventional dental metals in the near future, removable partial denture (RPD) frameworks will probably continue to be cast with biocompatible metals. Commercially pure (CP) titanium has appropriate mechanical properties, it is lightweight (low density) compared with conventional dental alloys, and has outstanding biocompatibility that prevents metal allergic reactions. This literature review describes the laboratory conditions needed for fabricating titanium frameworks and the present status of titanium removable prostheses. The use of titanium for the production of cast RPD frameworks has gradually increased. There are no reports about metallic allergy apparently caused by CP titanium dentures. The laboratory drawbacks still remain, such as the lengthy burn-out, inferior castability and machinability, reaction layer formed on the cast surface, difficulty of polishing, and high initial costs. However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of clasp retention, tendency for plaque to adhere to the surface, detachment of the denture base resin, and severe wear of titanium teeth, have gradually been resolved. Titanium RPD frameworks have never been reported to fail catastrophically. Thus, titanium is recommended as protection against metal allergy, particularly for large-sized prostheses such as RPDs or complete dentures.

  8. Barodontalgia as a differential diagnosis: symptoms and findings.

    PubMed

    Robichaud, Roland; McNally, Mary E

    2005-01-01

    This paper provides a review of the literature concerning the etiology and manifestations of barodontalgia, as well as important clinical considerations for its management. Barodontalgia is characterized by exposure to a pressure gradient, such as that experienced by underwater divers, aviation personnel and air travellers. This form of dental pain is generally marked by a predisposing dental pathology such as acute or chronic periapical infection, caries, deep or failing restorations, residual dental cysts, sinusitis or a history of recent surgery. Studies indicate that severity of barodontalgia and the resulting deterioration of dental health correlates with duration of barometric stress. Restorative materials are also affected by pressure gradients. Resin is indicated as a luting agent of choice for cementing fixed prostheses in populations at risk for barodontalgia. Under the influence of pressure gradients, resin cements maintain original bond strength and demonstrate the least amount of microleakage compared with other cements. The key to avoiding barodontalgia is good oral health. Clinicians must pay close attention to areas of dentin exposure, caries, fractured cusps, the integrity of restorations and periapical pathology in those at risk. The Fédération dentaire internationale describes 4 classes of barodontalgia based on signs and symptoms and provides specific and valuable recommendations for therapeutic intervention.

  9. Addition of a pontic to all-ceramic Turkom-Cera fixed partial denture restorations

    PubMed Central

    Uludag, Bulent; Tokar, Emre; Polat, Serdar

    2013-01-01

    High-strength all-ceramic materials are commonly used in dentistry. When complications occur in an all-ceramic restoration, the restoration is usually replaced. This article describes the time-saving ability and cost-effectiveness of this novel technique for the addition of a pontic in two complicated clinical cases. Turkom-Cera™ [Turkom-Ceramic (M) Sdn. Bhd.] with aluminum oxide (99.98%) is an all-ceramic system that offers the option of addition of a new pontic to the sintered framework. The new pontic was cut off from an alumina blank [Turkom-Ceramic (M) Sdn. Bhd.], moistened, and attached to the framework using alumina gel [Turkom-Ceramic (M) Sdn. Bhd.]. The framework was veneered with veneering porcelain (Vita VM 7; VITA Zahnfabrik). The two cases presented here involving the addition of a pontic to sintered framework were followed up for at least 1 year. No complication was detected or reported by the patients. Alumina- and zirconia-based ceramics are particularly suitable for for all-ceramic restorations in high-stress bearing areas. However, replacement of a failed all-ceramic restoration is not the most practical solution, considering both cost and tooth-related factors. This attractive feature of the Turkom-Cera allows the repair of a fractured ceramic coping or the addition of a new pontic to restorations. PMID:24883033

  10. Atypical Chronic Ankle Instability in a Pediatric Population Secondary to Distal Fibula Avulsion Fracture Nonunion.

    PubMed

    El Ashry, Saad R; El Gamal, Tarek A; Platt, Simon R

    Chronic ankle instability is a disabling condition, often occurring as a result of traumatic ankle injury. A paucity of published data is available documenting chronic ankle instability in the pediatric population. Much of the data has been confined to the adult population. We present 2 cases of chronic ankle instability, 1 in a 12-year-old and 1 in a 9-year-old patient. Unlike the typical adult etiology, the cause of instability was a dysfunctional lateral ligamentous complex as a consequence of bony avulsion of the tip of the fibula. Both patients had sustained a twisting injury to the ankle. The fractures failed to unite. The nonunion resulted in dysfunction of the anterior talofibular ligament with consequent chronic ankle instability. At the initial clinical assessment, magnetic resonance imaging was requested for both patients. In patient 1 (12 years old), the fracture was fixed with 2 headless screws and was immobilized in a plaster cast for 6 weeks. In patient 2 (9 years old), because of the small size of the avulsed fragment, fixation was not possible. A modified Gould-Broström procedure was undertaken, facilitating repair of the avulsed fragment using anchor sutures. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Evaluating the Medical Symptom Validity Test (MSVT) in a Sample of Veterans Between the Ages of 18 to 64.

    PubMed

    Reslan, Summar; Axelrod, Bradley N

    2017-01-01

    The purpose of the current study was to compare three potential profiles of the Medical Symptom Validity Test (MSVT; Pass, Genuine Memory Impairment Profile [GMIP], and Fail) on other freestanding and embedded performance validity tests (PVTs). Notably, a quantitatively computed version of the GMIP was utilized in this investigation. Data obtained from veterans referred for a neuropsychological evaluation in a metropolitan Veteran Affairs medical center were included (N = 494). Individuals age 65 and older were not included to exclude individuals with dementia from this investigation. The sample revealed 222 (45%) in the Pass group. Of the 272 who failed the easy subtests of the MSVT, 221 (81%) met quantitative criteria for the GMIP and 51 (19%) were classified as Fail. The Pass group failed fewer freestanding and embedded PVTs and obtained higher raw scores on all PVTs than both GMIP and Fail groups. The differences in performances of the GMIP and Fail groups were minimal. Specifically, GMIP protocols failed fewer freestanding PVTs than the Fail group; failure on embedded PVTs did not differ between GMIP and Fail. The MSVT GMIP incorporates the presence of clinical correlates of disability to assist with this distinction, but future research should consider performances on other freestanding measures of performance validity to differentiate cognitive impairment from invalidity.

  12. Clinical Nursing Records Study

    DTIC Science & Technology

    1991-08-01

    In-depth assessment of current AMEDD nursing documentation system used in fixed facilities; 2 - 4) development, implementation and assessment of...used in fixed facilities to: a) identify system problems; b) identify potential solutions to problems; c) set priorities fc problem resolution; d...enhance compatibility between any " hard copy" forms the group might develop and automation requirements. Discussions were also held with personnel from

  13. The Shedler-Westen Assessment Procedure (SWAP): Evaluating Psychometric Questions about Its Reliability, Validity, and Impact of Its Fixed Score Distribution

    ERIC Educational Resources Information Center

    Blagov, Pavel S.; Bi, Wu; Shedler, Jonathan; Westen, Drew

    2012-01-01

    The Shedler-Westen Assessment Procedure (SWAP) is a personality assessment instrument designed for use by expert clinical assessors. Critics have raised questions about its psychometrics, most notably its validity across observers and situations, the impact of its fixed score distribution on research findings, and its test-retest reliability. We…

  14. Single-Incision Laparoscopic Intraperitoneal Onlay Mesh Repair for the Treatment of Multiple Recurrent Inguinal Hernias

    PubMed Central

    Tran, Kim; Zajkowska, Marta; Lam, Vincent; Hawthorne, Wayne

    2014-01-01

    Introduction: Despite an exponential rise in laparoscopic surgery for inguinal herniorrhaphy, overall recurrence rates have remained unchanged. Therefore, an increasing number of patients present with recurrent hernias after having failed anterior and laparoscopic repairs. This study reports our experience with single-incision laparoscopic (SIL) intraperitoneal onlay mesh (IPOM) repair for these hernias. Materials and methods: All patients referred with multiply recurrent inguinal hernias underwent SIL-IPOM from November 1 2009 to October 30 2013. A 2.5-cm infraumbilical incision was made and a SIL surgical port was placed intraperitoneally. Modified dissection techniques, namely, “chopsticks” and “inline” dissection, 5.5 mm/52 cm/30° angled laparoscope and conventional straight dissecting instruments were used. The peritoneum was incised above the symphysis pubis and dissection continued laterally and proximally raising an inferior flap, below a previous extraperitoneal mesh, while reducing any direct/indirect/femoral/cord lipoma before placement of antiadhesive mesh that was fixed into the pubic ramus as well as superiorly with nonabsorbable tacks before fixing its inferior border with fibrin sealant. The inferior peritoneal flap was then tacked back onto the mesh. Results: There were 9 male patients who underwent SIL-IPOM. Mean age was 55 years old and mean body mass index was 26.8 kg/m2. Mean mesh size was 275 cm2. Mean operation time was 125 minutes with hospital stay of 1 day and umbilical scar length of 21 mm at 4 weeks' follow-up. There were no intraoperative/postoperative complications, port-site hernias, chronic groin pain, or recurrence with mean follow-up of 20 months. Conclusions: Multiply recurrent inguinal hernias after failed conventional anterior and laparoscopic repairs can be treated safely and efficiently with SIL-IPOM. PMID:25392643

  15. Porous filtering media comparison through wet and dry sampling of fixed bed gasification products

    NASA Astrophysics Data System (ADS)

    Allesina, G.; Pedrazzi, S.; Montermini, L.; Giorgini, L.; Bortolani, G.; Tartarini, P.

    2014-11-01

    The syngas produced by fixed bed gasifiers contains high quantities of particulate and tars. This issue, together with its high temperature, avoids its direct exploitation without a proper cleaning and cooling process. In fact, when the syngas produced by gasification is used in an Internal Combustion engine (IC), the higher the content of tars and particulate, the higher the risk to damage the engine is. If these compounds are not properly removed, the engine may fail to run. A way to avoid engine fails is to intensify the maintenance schedule, but these stops will reduce the system profitability. From a clean syngas does not only follow higher performance of the generator, but also less pollutants in the atmosphere. When is not possible to work on the gasification reactions, the filter plays the most important role in the engine safeguard process. This work is aimed at developing and comparing different porous filters for biomass gasifiers power plants. A drum filter was developed and tested filling it with different filtering media available on the market. As a starting point, the filter was implemented in a Power Pallet 10 kW gasifier produced by the California-based company "ALL Power Labs". The original filter was replaced with different porous biomasses, such as woodchips and corn cobs. Finally, a synthetic zeolites medium was tested and compared with the biological media previously used. The Tar Sampling Protocol (TSP) and a modified "dry" method using the Silica Gel material were applied to evaluate the tars, particulate and water amount in the syngas after the filtration process. Advantages and disadvantages of every filtering media chosen were reported and discussed.

  16. Influence of retainer design on two-unit cantilever resin-bonded glass fiber reinforced composite fixed dental prostheses: an in vitro and finite element analysis study.

    PubMed

    Keulemans, Filip; De Jager, Niek; Kleverlaan, Cornelis J; Feilzer, Albert J

    2008-10-01

    The aim of this study was to evaluate in vitro the influence of retainer design on the strength of two-unit cantilever resin-bonded glass fiber-reinforced composite (FRC) fixed dental prostheses (FDP). Four retainer designs were tested: a proximal box, a step-box, a dual wing, and a step-box-wing. Of each design on 8 human mandibular molars, FRC-FDPs of a premolar size were produced. The FRC framework was made of resin impregnated unidirectional glass fibers (Estenia C&B EG Fiber, Kuraray) and veneered with hybrid resin composite (Estenia C&B, Kuraray). Panavia F 2.0 (Kuraray) was used as resin luting cement. FRC-FDPs were loaded to failure in a universal testing machine. One-way ANOVA and Tukey's post-hoc test were used to evaluate the data. The four designs were analyzed with finite element analysis (FEA) to reveal the stress distribution within the tooth/restoration complex. Significantly lower fracture strengths were observed with inlay-retained FDPs (proximal box: 300 +/- 65 N; step-box: 309 +/- 37 N) compared to wing-retained FDPs (p < 0.05) (step-box-wing: 662 +/- 99 N; dual wing: 697 +/- 67 N). Proximal-box-, step-box-, and step-box-wing-retained FDPs mainly failed with catastrophic cusp fracture (proximal box 100%, step-box 100%, and step-box-wing 75%), while dual-wing-retained FDPs mainly failed at the adhesive interface and/or due to pontic failure (75%). FEA showed more favorable stress distributions within the tooth/restoration complex for dual wing retainers. A dual-wing retainer is the optimal design for replacement of a single premolar by means of a two-unit cantilever FRC-FDPs.

  17. Implant dentistry curriculum in undergraduate education: part 2-program at the Albert-Ludwigs University, Freiburg, Germany.

    PubMed

    Kroeplin, Birgit S; Strub, Joerg R

    2011-01-01

    The aim of this study was to describe the didactic and clinical undergraduate implant dentistry program of the Albert-Ludwigs University, Freiburg, Germany, with emphasis on the clinical implant experience. A detailed description of the implant curriculum at Albert-Ludwigs University is given with documented exemplary cases and additional flow charts. All students participate in 28 hours of lectures and approximately 64 hours of seminars with hands-on courses and gain clinical experience. All undergraduate students are eligible to place and restore oral implants. Emphasis is placed on prosthetic-driven planning of implant positions, three-dimensional imaging, and computer-guided implant placement. Implant restorations performed by undergraduate students comprise single crowns and small multiunit fixed dental prostheses in partially edentulous posterior maxillae and anterior or posterior mandibles, implant-retained overdentures (snap attachment) in edentulous patients, and telescopic fixed-removable dental prostheses on remaining teeth and strategically placed additional implants. Over the past 2.5 years, 51 patients were treated with 97 dental implants placed by students in the undergraduate program. Seventy-one restorations were inserted: 60.6% single crowns, 7% fixed dental protheses, 21.1% overdentures, and 11.3% telescopic fixed-removable dental prostheses. The implant survival rate was 98.9%. Because survival rates for dental implants placed and restored by students are comparable to those of experienced dentists, oral implant dentistry should be implemented as part of the undergraduate dental curriculum.

  18. [Prognostic value of changes in concentration of brain natriuretic peptide, TNF-alpha factor and Interleukin-6 in chronic cardiac failure].

    PubMed

    Volkova, S Iu

    2008-01-01

    During 6 months therapy initial and final N-terminal pro-B-type natriuretic peptide. TNF-alpha, and IL-6 level in blood plasma were determined in 61 ischemic CHI cases with left ventricular ejection fraction below 40%. The patients were followed up for next 24.7 +/- 11.5 months. In period of 6 months following up associated with performed therapy 67.9% of patients showed a positive clinical effect, combined with a decrease of plasma pools of neurohumoral mediators (NM) in 51.4%-71.4% of cases (in dependence on studied NM). There were selected the 4 variants of combinations of clinical efficacy and NM dynamics which failed to coincide in a half of observations for NT-pro BNP and IL-6, and in a third for TNF-alpha. Multivariate analysis of conformities showed, that a decrease of all NM during therapy significantly relates with patient surviving. In a group with a decrease of plasma NT-pro BNP level associated with therapy during consequent following up no lethal outcome was recorded, compared to 16% in a group with a rise in NT-pro BNP (a = 0.2). Lethal outcome was fixed in 4.2% in a group with a decrease in TNF-alpha, compared to 33.3% in a group with elevation in TNF-alpha (a = 0.016); and in 5% in a group with a fall in IL-6, compared to 23.1% in a group with an elevation of IL-6 (a = 0.04).

  19. How does esophagus look on barium esophagram in pediatric eosinophilic esophagitis?

    PubMed

    Al-Hussaini, Abdulrahman; AboZeid, Amany; Hai, Abdul

    2016-08-01

    The clinical, endoscopic, and histologic findings of eosinophilic esophagitis (EoE) are well characterized; however, there have been very limited data regarding the radiologic findings of pediatric EoE. We report on the radiologic findings of pediatric EoE observed on barium esophagram and correlate them with the endoscopic findings. We identified children diagnosed with EoE in our center from 2004 to 2015. Two pediatric radiologists met after their independent evaluations of each fluoroscopic study to reach a consensus on each case. Clinical and endoscopic data were collected by retrospective chart review. Twenty-six pediatric EoE cases (age range 2-13 years; median 7.5 years) had barium esophagram done as part of the diagnostic approach for dysphagia. Thirteen children had abnormal radiologic findings of esophagus (50%): rings formation (n = 4), diffuse irregularity of mucosa (n = 8), fixed stricture formation (n = 3), and narrow-caliber esophagus (n = 10). Barium esophagram failed to show one of 10 cases of narrow-caliber esophagus and 10 of 14 cases of rings formation visualized endoscopically. The mean duration of symptoms prior to diagnosis of EoE was longer (3.7 vs. 1.7 year; p value 0.019), and the presentation with intermittent food impaction was commoner in the group with abnormal barium esophagram as compared to the group with normal barium esophagram (69% vs. 8%; p value 0.04). Barium swallow study is frequently normal in pediatric EoE. With the exception of narrow-caliber esophagus, our data show poor correlation between radiologic and endoscopic findings.

  20. Reforms speed initiation of NCI-sponsored clinical trials

    Cancer.gov

    The process of opening a cancer clinical trial for patient accrual often takes years, and research has shown that trials which are slow to register patients often fail to finish. Following a thorough review, NCI’s Operational Efficiency Working Group prod

  1. Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts

    PubMed Central

    Sukotjo, Cortino

    2013-01-01

    Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices. PMID:23678387

  2. Tendon healing in a bone tunnel. Part I: Biomechanical results after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep.

    PubMed

    Weiler, Andreas; Peine, Ricarda; Pashmineh-Azar, Alireza; Abel, Clemens; Südkamp, Norbert P; Hoffmann, Reinhard F G

    2002-02-01

    Interference fit fixation of soft-tissue grafts has recently raised strong interest because it allows for anatomic graft fixation that may increase knee stability and graft isometry. Although clinical data show promising results, no data exist on how tendon healing progresses using this fixation. The purpose of the present study was to investigate anterior cruciate ligament (ACL) reconstruction biomechanically using direct tendon-to-bone interference fit fixation with biodegradable interference screws in a sheep model. Animal study. Thirty-five mature sheep underwent ACL reconstruction with an autologous Achilles tendon split graft. Grafts were directly fixed with poly-(D,L-lactide) interference screws. Animals were euthanized after 6, 9, 12, 24, and 52 weeks and standard biomechanical evaluations were performed. All grafts at time zero failed by pullout from the bone tunnel, whereas grafts at 6 and 9 weeks failed intraligamentously at the screw insertion site. At 24 and 52 weeks, grafts failed by osteocartilaginous avulsion. At 24 weeks, interference screws were macroscopically degraded. At 6 and 9 weeks tensile stress was only 6.8% and 9.6%, respectively, of the graft tissue at time zero. At 52 weeks, tensile stress of the reconstruction equaled 63.8% and 47.3% of the Achilles tendon graft at time zero and the native ACL, respectively. A complete restitution of anterior-posterior drawer displacement was found at 52 weeks compared with the time-zero reconstruction. It was found that over the whole healing period the graft fixation proved not to be the weak link of the reconstruction and that direct interference fit fixation withstands loads without motion restriction in the present animal model. The weak link during the early healing stage was the graft at its tunnel entrance site, leading to a critical decrease in mechanical properties. This finding indicates that interference fit fixation of a soft-tissue graft may additionally alter the mechanical properties of the graft in the early remodeling stage because of a possible tissue compromise at the screw insertion site. Although mechanical properties of the graft tissue had not returned to normal at 1 year compared with those at time zero, knee stability had returned to normal at that time. There was no graft pullout after 24 weeks, indicating that screw degradation does not compromise graft fixation.

  3. Integrated identification and control for nanosatellites reclaiming failed satellite

    NASA Astrophysics Data System (ADS)

    Han, Nan; Luo, Jianjun; Ma, Weihua; Yuan, Jianping

    2018-05-01

    Using nanosatellites to reclaim a failed satellite needs nanosatellites to attach to its surface to take over its attitude control function. This is challenging, since parameters including the inertia matrix of the combined spacecraft and the relative attitude information of attached nanosatellites with respect to the given body-fixed frame of the failed satellite are all unknown after the attachment. Besides, if the total control capacity needs to be increased during the reclaiming process by new nanosatellites, real-time parameters updating will be necessary. For these reasons, an integrated identification and control method is proposed in this paper, which enables the real-time parameters identification and attitude takeover control to be conducted concurrently. Identification of the inertia matrix of the combined spacecraft and the relative attitude information of attached nanosatellites are both considered. To guarantee sufficient excitation for the identification of the inertia matrix, a modified identification equation is established by filtering out sample points leading to ill-conditioned identification, and the identification performance of the inertia matrix is improved. Based on the real-time estimated inertia matrix, an attitude takeover controller is designed, the stability of the controller is analysed using Lyapunov method. The commanded control torques are allocated to each nanosatellite while the control saturation constraint being satisfied using the Quadratic Programming (QP) method. Numerical simulations are carried out to demonstrate the feasibility and effectiveness of the proposed integrated identification and control method.

  4. When Fathering Fails: Violence, Narcissism, and the Father Function in Ancient Tales and Clinical Analysis.

    PubMed

    Diamond, Michael J

    2018-02-01

    Manifestations of failures in both symbolic and actual flesh-and-blood fathering reveal the inescapable role played by the father's unconscious transmissions in the ever present triadic matrix. Perelberg's crucial distinction between the murdered narcissistic father and the dead symbolic father suggests the problematic internalizations that fail to uphold the paternal law required for oedipal resolution. Three father-child narratives derived from classical literature and mythology are presented in order to elucidate significant unconscious paternal fantasies pertaining to lethal rivalry and neglect of the child's otherness. These narratives suggest how the father's insufficient management of rivalrous, envious, and murderously aggressive impulses-as well as narcissistic needs that fail to take into account the child's alterity-combine with the child's intrapsychic propensities to constrict triangular space and restrict development. Consequently, unavoidable father-child rivalries, absences, neglect, and desires often make it vital to recover the "missing" paternal function in analytic space. A clinical example illustrates the impact of this absence on the analyst's countertransference.

  5. Adhesives for fixed orthodontic bands.

    PubMed

    Millett, Declan T; Glenny, Anne-Marie; Mattick, Rye Cr; Hickman, Joy; Mandall, Nicky A

    2016-10-25

    Orthodontic treatment involves using fixed or removable appliances (dental braces) to correct the positions of teeth. It has been shown that the quality of treatment result obtained with fixed appliances is much better than with removable appliances. Fixed appliances are, therefore, favoured by most orthodontists for treatment. The success of a fixed orthodontic appliance depends on the metal attachments (brackets and bands) being attached securely to the teeth so that they do not become loose during treatment. Brackets are usually attached to the front and side teeth, whereas bands (metal rings that go round the teeth) are more commonly used on the back teeth (molars). A number of adhesives are available to attach bands to teeth and it is important to understand which group of adhesives bond most reliably, as well as reducing or preventing dental decay during the treatment period. To evaluate the effectiveness of the adhesives used to attach bands to teeth during fixed appliance treatment, in terms of:(1) how often the bands come off during treatment; and(2) whether they protect the banded teeth against decay during fixed appliance treatment. The following electronic databases were searched: Cochrane Oral Health's Trials Register (searched 2 June 2016), Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 5) in the Cochrane Library (searched 2 June 2016), MEDLINE Ovid (1946 to 2 June 2016) and EMBASE Ovid (1980 to 2 June 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Randomised and controlled clinical trials (RCTs and CCTs) (including split-mouth studies) of adhesives used to attach orthodontic bands to molar teeth were selected. Patients with full arch fixed orthodontic appliance(s) who had bands attached to molars were included. All review authors were involved in study selection, validity assessment and data extraction without blinding to the authors, adhesives used or results obtained. All disagreements were resolved by discussion. Five RCTs and three CCTs were identified as meeting the review's inclusion criteria. All the included trials were of split-mouth design. Four trials compared chemically cured zinc phosphate and chemically cured glass ionomer; three trials compared chemically cured glass ionomer cement with light cured compomer; one trial compared chemically cured glass ionomer with a chemically cured glass phosphonate. Data analysis was often inappropriate within the studies meeting the inclusion criteria. There is insufficient high quality evidence with regard to the most effective adhesive for attaching orthodontic bands to molar teeth. Further RCTs are required.

  6. KommonBase - A precise direct bonding system for labial fixed appliances.

    PubMed

    Miyashita, Wataru; Komori, Akira; Takemoto, Kyoto

    2017-09-01

    "KommonBase" is a system designed to customize the bracket base by means of an extended resin base covering the tooth. This system enables precise bracket placement and accurate fit on teeth. Moreover, KommonBase can be easily fabricated in a laboratory and bonded on each tooth using simple clinical procedures. Straight-wire treatment without wire bending was achieved in the clinical cases presented in this article using the KommonBase system for a labial fixed appliance. The application of KommonBase to the vestibular side enables efficient orthodontic treatment using simple mechanics. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  7. Method of injection of onabotulinumtoxinA for chronic migraine: a safe, well-tolerated, and effective treatment paradigm based on the PREEMPT clinical program.

    PubMed

    Blumenfeld, Andrew; Silberstein, Stephen D; Dodick, David W; Aurora, Sheena K; Turkel, Catherine C; Binder, William J

    2010-10-01

    Chronic migraine (CM) is a prevalent and disabling neurological disorder. Few prophylactic treatments for CM have been investigated. OnabotulinumtoxinA, which inhibits the release of nociceptive mediators, such as glutamate, substance P, and calcitonin gene-related peptide, has been evaluated in randomized, placebo-controlled studies for the preventive treatment of a variety of headache disorders, including CM. These studies have yielded insight into appropriate patient selection, injection sites, dosages, and technique. Initial approaches used a set of fixed sites for the pericranial injections. However, the treatment approach evolved to include other sites that corresponded to the location of pain and tenderness in the individual patient in addition to the fixed sites. The Phase III REsearch Evaluating Migraine Prophylaxis Therapy (PREEMPT) injection paradigm uses both fixed and follow-the-pain sites, with additional specific follow-the-pain sites considered depending on individual symptoms. The PREEMPT paradigm for injecting onabotulinumtoxinA has been shown to be safe, well-tolerated, and effective in well-designed, controlled clinical trials and is the evidence-based approach recommended to optimize clinical outcomes for patients with CM. © 2010 American Headache Society.

  8. Full-mouth rehabilitation with immediate loading of implants inserted with computer-guided flap-less surgery: a 3-year multicenter clinical evaluation with oral health impact profile.

    PubMed

    Marra, Roberto; Acocella, Alessandro; Rispoli, Alessandra; Sacco, Roberto; Ganz, Scott D; Blasi, Andrea

    2013-10-01

    The purpose of this report is to present the clinical outcomes and patients' satisfaction of full-mouth rehabilitation using computer-aided flapless implant placement and immediate loading of a prefabricated prosthesis. The study included 30 consecutive fully edentulous patients who received 312 implants. Mandible and maxilla were treated in the same surgical session with computer-guided flapless approach using the NobelGuide protocol. Prefabricated screw-retained fixed prostheses were inserted at the end of surgery. Clinical and radiographic evaluations were assessed at 6, 12, and 36 months. At baseline and 6 months after surgery, patients answered Oral Health Impact Profile in Edentulous Adults questionnaire to assess satisfaction. The implant survival rate was 97.9%, whereas the average marginal bone loss was 1.9 ± 1.3 mm after 3 years. At 6 months, patients showed significantly greater satisfaction with their fixed rehabilitation when compared with conventional dentures. The results of this study confirm that rehabilitation with a prefabricated fixed prosthesis supported by implants placed with NobelGuide protocol is a viable and predictable treatment and increases patients' satisfaction and improves oral health-related quality of life.

  9. Management of Parkinson׳s disease: Current and future pharmacotherapy.

    PubMed

    Kakkar, Ashish Kumar; Dahiya, Neha

    2015-03-05

    Parkinson׳s disease (PD) is chronic progressive neurodegenerative disorder characterized by profound loss of dopaminergic neurons in the nigrostriatal pathway. It is recognized by the cardinal clinical features of bradykinesia, rigidity, tremor and postural instability. Current therapeutic options are primarily dopamine replacement strategies that only provide symptomatic improvement without affecting progressive neuronal loss. These treatments often fail to provide sustained clinical benefit and most patients develop motor fluctuations and dyskinesias as the disease progresses. Additionally, non-motor symptoms such as autonomic disturbances, sensory alterations, olfactory dysfunction, mood disorders, sleep disturbances and cognitive impairment cause considerable functional disability in these patients and these features often fail to respond to standard dopaminergic treatments. This mini review outlines the current pharmacotherapeutic options for PD and highlights the emerging experimental therapies in various phases of clinical development. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Self-verification in clinical depression: the desire for negative evaluation.

    PubMed

    Giesler, R B; Josephs, R A; Swann, W B

    1996-08-01

    Do clinically depressed individuals seek favorable or unfavorable information about the self? Self-verification theory makes the counterintuitive prediction that depressed individuals solicit feedback that confirms their negative self-views. To test this prediction, participants were classified on the basis of a structured clinical interview and self-report measures into high-esteem, low self-esteem, and depressed groups. All participants were offered a choice between receiving favorable or unfavorable feedback; 82% of the depressed participants chose the unfavorable feedback, compared to 64% of the low self-esteem participants and 25% of the high self-esteem participants. Additional evidence indicated that depressed individuals also failed to exploit fully an opportunity to acquire favorable evaluations that were self-verifying. The authors discuss how seeking negative evaluations and failing to seek favorable evaluations may help maintain depression.

  11. Treating patella fractures with a fixed-angle patella plate-A prospective observational study.

    PubMed

    Wild, Michael; Fischer, Kai; Hilsenbeck, Florian; Hakimi, Mohssen; Betsch, Marcel

    2016-08-01

    Anterior tension wiring using Kirschner wires (K-wires) is still considered the standard treatment for patella fractures, despite its high complication rate. The objective of this prospective clinical study was to evaluate intra- and perioperative complications as well as the clinical outcome of patients with patella fracture treated with a new developed bilateral, polyaxial, fixed-angle 2.7mm patella plate. Between 2011 and 2014 all patients with a patella fracture were included in this prospective study and treated with a fixed-angle patella plate. Avulsion fractures of the inferior or superior pole of the patella were excluded. All fractures were classified according to the AO/OTA fracture classification. During a twelve-month follow up period all intra- and postoperative complications were recorded as well as the time until fracture healing. One year postoperatively the Lysholm Score, the pre- and postoperative Tegner Score, the Hospital for Special Surgery Knee Score (HSS), the Turba Score, the Oxford Knee Score, the Knee injury and Osteoarthritis Outcome Score (KOOS), the Bostman Score and the Iowa Knee Score were surveyed. Altogether, 20 patella fractures in 19 patients were included in this prospective study. The most frequent type of fracture, n=10, was a simple transverse patella fracture (C1), followed by 7 comminuted patella fractures (C3) and 3 T-shaped patella fractures (C2). During the 12-month follow up period two patients treated with the patella plate had a complication. In one patient a superficial wound infection occurred, which was treated successfully with hardware removal and in one patient a fracture dislocation due to an implant failure occurred. X-rays demonstrated complete bony healing in all fractures on average 3.2 months postoperatively. All knee scores showed good to excellent clinical results one year postoperatively. The results of this first clinical study indicate that the fixed-angle patella plate is an effective and safe treatment option for patella fractures with a short operative learning curve. The treatment of communited patella fractures (C3) with a fixed-angle patella plate should be well-considered to avoid distending the indication and biomechanical properties. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Differential Weighting for Subcomponent Measures of Integrated Clinical Encounter Scores Based on the USMLE Step 2 CS Examination: Effects on Composite Score Reliability and Pass-Fail Decisions.

    PubMed

    Park, Yoon Soo; Lineberry, Matthew; Hyderi, Abbas; Bordage, Georges; Xing, Kuan; Yudkowsky, Rachel

    2016-11-01

    Medical schools administer locally developed graduation competency examinations (GCEs) following the structure of the United States Medical Licensing Examination Step 2 Clinical Skills that combine standardized patient (SP)-based physical examination and the patient note (PN) to create integrated clinical encounter (ICE) scores. This study examines how different subcomponent scoring weights in a locally developed GCE affect composite score reliability and pass-fail decisions for ICE scores, contributing to internal structure and consequential validity evidence. Data from two M4 cohorts (2014: n = 177; 2015: n = 182) were used. The reliability of SP encounter (history taking and physical examination), PN, and communication and interpersonal skills scores were estimated with generalizability studies. Composite score reliability was estimated for varying weight combinations. Faculty were surveyed for preferred weights on the SP encounter and PN scores. Composite scores based on Kane's method were compared with weighted mean scores. Faculty suggested weighting PNs higher (60%-70%) than the SP encounter scores (30%-40%). Statistically, composite score reliability was maximized when PN scores were weighted at 40% to 50%. Composite score reliability of ICE scores increased by up to 0.20 points when SP-history taking (SP-Hx) scores were included; excluding SP-Hx only increased composite score reliability by 0.09 points. Classification accuracy for pass-fail decisions between composite and weighted mean scores was 0.77; misclassification was < 5%. Medical schools and certification agencies should consider implications of assigning weights with respect to composite score reliability and consequences on pass-fail decisions.

  13. Challenges and opportunities in SLE clinical trials.

    PubMed

    van Vollenhoven, Ronald F

    2013-09-01

    To provide an update on the field of clinical trials in systemic lupus erythematosus (SLE). This review will examine failed and successful clinical trials in SLE in order to draw lessons and determine the optimal ways forward. Over the past decade, many clinical trials in SLE met with limited success, but in the past 2 years several SLE clinical trials have been successful. The two large phase III randomized controlled trials (RCTs) of belimumab achieved their primary endpoints and resulted in food and drug administration and European medicines agency approval of the drug. Characteristics of these trials were, among other things, a very large number of patients (>800 each), compound clinical endpoints, and a flexible design with regards to concomitant medication use. Likewise, large randomized controlled trials with mycophenolate mofetil, although nominally unsuccessful, clearly demonstrated the clinical benefit of this drug in lupus nephritis. Posthoc analyses of several failed trials involving abatacept and rituximab revealed design elements and/or outcomes that might have changed the outcomes of these studies. Many smaller trials have also been reported, in some instances with surprisingly positive results. An improved understanding of specific design features in SLE clinical trials combined with robust outcomes will make it possible more effectively to design and conduct clinical trials in SLE.

  14. Performance sustaining intracortical neural prostheses

    NASA Astrophysics Data System (ADS)

    Nuyujukian, Paul; Kao, Jonathan C.; Fan, Joline M.; Stavisky, Sergey D.; Ryu, Stephen I.; Shenoy, Krishna V.

    2014-12-01

    Objective. Neural prostheses, or brain-machine interfaces, aim to restore efficient communication and movement ability to those suffering from paralysis. A major challenge these systems face is robust performance, particularly with aging signal sources. The aim in this study was to develop a neural prosthesis that could sustain high performance in spite of signal instability while still minimizing retraining time. Approach. We trained two rhesus macaques implanted with intracortical microelectrode arrays 1-4 years prior to this study to acquire targets with a neurally-controlled cursor. We measured their performance via achieved bitrate (bits per second, bps). This task was repeated over contiguous days to evaluate the sustained performance across time. Main results. We found that in the monkey with a younger (i.e., two year old) implant and better signal quality, a fixed decoder could sustain performance for a month at a rate of 4 bps, the highest achieved communication rate reported to date. This fixed decoder was evaluated across 22 months and experienced a performance decline at a rate of 0.24 bps yr-1. In the monkey with the older (i.e., 3.5 year old) implant and poorer signal quality, a fixed decoder could not sustain performance for more than a few days. Nevertheless, performance in this monkey was maintained for two weeks without requiring additional online retraining time by utilizing prior days’ experimental data. Upon analysis of the changes in channel tuning, we found that this stability appeared partially attributable to the cancelling-out of neural tuning fluctuations when projected to two-dimensional cursor movements. Significance. The findings in this study (1) document the highest-performing communication neural prosthesis in monkeys, (2) confirm and extend prior reports of the stability of fixed decoders, and (3) demonstrate a protocol for system stability under conditions where fixed decoders would otherwise fail. These improvements to decoder stability are important for minimizing training time and should make neural prostheses more practical to use.

  15. A new approach to blind deconvolution of astronomical images

    NASA Astrophysics Data System (ADS)

    Vorontsov, S. V.; Jefferies, S. M.

    2017-05-01

    We readdress the strategy of finding approximate regularized solutions to the blind deconvolution problem, when both the object and the point-spread function (PSF) have finite support. Our approach consists in addressing fixed points of an iteration in which both the object x and the PSF y are approximated in an alternating manner, discarding the previous approximation for x when updating x (similarly for y), and considering the resultant fixed points as candidates for a sensible solution. Alternating approximations are performed by truncated iterative least-squares descents. The number of descents in the object- and in the PSF-space play a role of two regularization parameters. Selection of appropriate fixed points (which may not be unique) is performed by relaxing the regularization gradually, using the previous fixed point as an initial guess for finding the next one, which brings an approximation of better spatial resolution. We report the results of artificial experiments with noise-free data, targeted at examining the potential capability of the technique to deconvolve images of high complexity. We also show the results obtained with two sets of satellite images acquired using ground-based telescopes with and without adaptive optics compensation. The new approach brings much better results when compared with an alternating minimization technique based on positivity-constrained conjugate gradients, where the iterations stagnate when addressing data of high complexity. In the alternating-approximation step, we examine the performance of three different non-blind iterative deconvolution algorithms. The best results are provided by the non-negativity-constrained successive over-relaxation technique (+SOR) supplemented with an adaptive scheduling of the relaxation parameter. Results of comparable quality are obtained with steepest descents modified by imposing the non-negativity constraint, at the expense of higher numerical costs. The Richardson-Lucy (or expectation-maximization) algorithm fails to locate stable fixed points in our experiments, due apparently to inappropriate regularization properties.

  16. A single CD4 test with 250 cells/mm3 threshold predicts viral suppression in HIV-infected adults failing first-line therapy by clinical criteria.

    PubMed

    Gilks, Charles F; Walker, A Sarah; Munderi, Paula; Kityo, Cissy; Reid, Andrew; Katabira, Elly; Goodall, Ruth L; Grosskurth, Heiner; Mugyenyi, Peter; Hakim, James; Gibb, Diana M

    2013-01-01

    In low-income countries, viral load (VL) monitoring of antiretroviral therapy (ART) is rarely available in the public sector for HIV-infected adults or children. Using clinical failure alone to identify first-line ART failure and trigger regimen switch may result in unnecessary use of costly second-line therapy. Our objective was to identify CD4 threshold values to confirm clinically-determined ART failure when VL is unavailable. 3316 HIV-infected Ugandan/Zimbabwean adults were randomised to first-line ART with Clinically-Driven (CDM, CD4s measured but blinded) or routine Laboratory and Clinical Monitoring (LCM, 12-weekly CD4s) in the DART trial. CD4 at switch and ART failure criteria (new/recurrent WHO 4, single/multiple WHO 3 event; LCM: CD4<100 cells/mm(3)) were reviewed in 361 LCM, 314 CDM participants who switched over median 5 years follow-up. Retrospective VLs were available in 368 (55%) participants. Overall, 265/361 (73%) LCM participants failed with CD4<100 cells/mm(3); only 7 (2%) switched with CD4≥250 cells/mm(3), four switches triggered by WHO events. Without CD4 monitoring, 207/314 (66%) CDM participants failed with WHO 4 events, and 77(25%)/30(10%) with single/multiple WHO 3 events. Failure/switching with single WHO 3 events was more likely with CD4≥250 cells/mm(3) (28/77; 36%) (p = 0.0002). CD4 monitoring reduced switching with viral suppression: 23/187 (12%) LCM versus 49/181 (27%) CDM had VL<400 copies/ml at failure/switch (p<0.0001). Amongst CDM participants with CD4<250 cells/mm(3) only 11/133 (8%) had VL<400 copies/ml, compared with 38/48 (79%) with CD4≥250 cells/mm(3) (p<0.0001). Multiple, but not single, WHO 3 events predicted first-line ART failure. A CD4 threshold 'tiebreaker' of ≥250 cells/mm(3) for clinically-monitored patients failing first-line could identify ∼80% with VL<400 copies/ml, who are unlikely to benefit from second-line. Targeting CD4s to single WHO stage 3 'clinical failures' would particularly avoid premature, costly switch to second-line ART.

  17. A Single CD4 Test with 250 Cells/Mm3 Threshold Predicts Viral Suppression in HIV-Infected Adults Failing First-Line Therapy by Clinical Criteria

    PubMed Central

    Munderi, Paula; Kityo, Cissy; Reid, Andrew; Katabira, Elly; Goodall, Ruth L.; Grosskurth, Heiner; Mugyenyi, Peter; Hakim, James; Gibb, Diana M.

    2013-01-01

    Background In low-income countries, viral load (VL) monitoring of antiretroviral therapy (ART) is rarely available in the public sector for HIV-infected adults or children. Using clinical failure alone to identify first-line ART failure and trigger regimen switch may result in unnecessary use of costly second-line therapy. Our objective was to identify CD4 threshold values to confirm clinically-determined ART failure when VL is unavailable. Methods 3316 HIV-infected Ugandan/Zimbabwean adults were randomised to first-line ART with Clinically-Driven (CDM, CD4s measured but blinded) or routine Laboratory and Clinical Monitoring (LCM, 12-weekly CD4s) in the DART trial. CD4 at switch and ART failure criteria (new/recurrent WHO 4, single/multiple WHO 3 event; LCM: CD4<100 cells/mm3) were reviewed in 361 LCM, 314 CDM participants who switched over median 5 years follow-up. Retrospective VLs were available in 368 (55%) participants. Results Overall, 265/361 (73%) LCM participants failed with CD4<100 cells/mm3; only 7 (2%) switched with CD4≥250 cells/mm3, four switches triggered by WHO events. Without CD4 monitoring, 207/314 (66%) CDM participants failed with WHO 4 events, and 77(25%)/30(10%) with single/multiple WHO 3 events. Failure/switching with single WHO 3 events was more likely with CD4≥250 cells/mm3 (28/77; 36%) (p = 0.0002). CD4 monitoring reduced switching with viral suppression: 23/187 (12%) LCM versus 49/181 (27%) CDM had VL<400 copies/ml at failure/switch (p<0.0001). Amongst CDM participants with CD4<250 cells/mm3 only 11/133 (8%) had VL<400copies/ml, compared with 38/48 (79%) with CD4≥250 cells/mm3 (p<0.0001). Conclusion Multiple, but not single, WHO 3 events predicted first-line ART failure. A CD4 threshold ‘tiebreaker’ of ≥250 cells/mm3 for clinically-monitored patients failing first-line could identify ∼80% with VL<400 copies/ml, who are unlikely to benefit from second-line. Targeting CD4s to single WHO stage 3 ‘clinical failures’ would particularly avoid premature, costly switch to second-line ART. PMID:23437399

  18. Satisfaction and Clinical Outcomes Among Patients with Immediately Loaded Mandibular Overdentures Supported by One or Two Dental Implants: Results of a 5-Year Prospective Randomized Clinical Trial.

    PubMed

    Kronstrom, Mats; Davis, Ben; Loney, Robert; Gerrow, Jack; Hollender, Lars

    The purpose of this study was to evaluate patient satisfaction and clinical outcomes among subjects with mandibular overdentures supported by one or two immediately placed dental implants 5 years after loading. Thirty-six subjects (16 men and 20 women) received one or two dental implants in the anterior mandible, and all implants were loaded the day of surgery. Subjects were scheduled for follow-up 3-, 6-, and 12 months after implant placement and thereafter annually for 4 more years. Patient satisfaction scores were measured with the Oral Health Impact Profile-EDENT (OHIPEDENT) questionnaire. Seventeen subjects (7 male and 10 female) with a mean age of 59.4 years (range, 44 to 74 years) were available for the 5-year follow-up examination. Nine subjects with 10 failing implants were excluded during the first year and nine subjects were lost to follow-up. No implants failed between the 12- and 60-month follow-up examinations, and the need for denture maintenance was low. Mean peri-implant bone change was 0.92 mm, and the Spearman test failed to show correlation between the insertion torque value and implant stability quotient. Patient satisfaction scores increased significantly when compared with baseline values and continued to be high for both groups, with no significant differences. Ten implants in nine subjects failed early, but no failures were observed after the 12-month examination. No significant differences were found between subjects in the two groups with respect to implant survival rates and peri-implant bone loss, and patient satisfaction scores continued to be high. Although patient satisfaction and implant success were high during the 12- to 60-month period, the results should be interpreted with caution because of the high number of failing implants and patients lost to follow-up. More research is needed to study outcomes of treatment with immediately loaded mandibular implant overdentures.

  19. Single-operator EUS-guided cholangiopancreatography for difficult pancreaticobiliary access (with video).

    PubMed

    Brauer, Brian C; Chen, Yang K; Fukami, Norio; Shah, Raj J

    2009-09-01

    When conventional ERCP methods fail because of periampullary or ductal obstruction, EUS-guided cholangiopancreatography (EUS-CP) may aid in pancreaticobiliary access. To report our experience when using single-operator EUS-CP. An academic tertiary-referral center. Consecutive patients undergoing EUS-CP were prospectively identified. These patients had undergone failed attempt(s) at therapeutic ERCP. A data sheet was used to record indications, reasons for failed ERCP, EUS-CP visualization of the duct of interest, transpapillary or transenteric intervention, clinical follow-up, and complications. Technical success was decompression of the duct of interest. Clinical success was resolution of jaundice or a > or = 50% reduction in pain or narcotics, as applicable. Between February 2003 and June 2007, EUS-CP was attempted in 20 patients (11 men, 9 women; mean [SD] age 58 +/- 14.9 years). Indications included jaundice (n = 8), biliary stones (n = 3), chronic pancreatitis (n = 6), acute pancreatitis (n = 2), and papillary stenosis (n = 1). Reasons for failed ERCP included periampullary mass (n = 8), intradiverticular papillae (n = 4), and pancreatic duct (PD) stricture (n = 7) or stone (n = 1). Technical success was achieved in 18 of 20 patients (90%). Biliary decompression was obtained in 11 of 12 patients (92%) (7 transpapillary and 4 transenteric-transcholedochal). Pancreatic decompression was obtained in 7 of 8 patients (88%) (3 transpapillary, 4 transgastric). On follow-up, clinical improvement was noted in 15 of 20 patients (70%). For treatment of pain associated with chronic pancreatitis, pain scores decreased by a mean of 1.75 (P = .18). Complications (in 2 of 20 [10%]) included perforation (n = 1) and respiratory failure (n = 1). A single-center nonrandomized observational study with a small patient population. At our academic referral center, single-operator EUS-CP provided decompression of obstructed ducts and may be performed after a failed attempt at conventional ERCP during the same endoscopic session.

  20. Effectiveness of Vildagliptin in Clinical Practice: Pooled Analysis of Three Korean Observational Studies (the VICTORY Study).

    PubMed

    Suh, Sunghwan; Song, Sun Ok; Kim, Jae Hyeon; Cho, Hyungjin; Lee, Woo Je; Lee, Byung-Wan

    2017-01-01

    The present observational study aimed to evaluate the clinical effectiveness of vildagliptin with metformin in Korean patients with type 2 diabetes mellitus (T2DM). Data were pooled from the vildagliptin postmarketing survey (PMS), the vildagliptin/metformin fixed drug combination (DC) PMS, and a retrospective observational study of vildagliptin/metformin (fixed DC or free DC). The effectiveness endpoint was the proportion of patients who achieved a glycemic target (HbA1c) of ≤7.0% at 24 weeks. In total, 4303 patients were included in the analysis; of these, 2087 patients were eligible. The mean patient age was 56.99 ± 11.25 years. Overall, 58.94% patients achieved an HbA1c target of ≤7.0% at 24 weeks. The glycemic target achievement rate was significantly greater in patients with baseline HbA1c < 7.5% versus ≥7.5% (84.64% versus 43.97%), receiving care at the hospital versus clinic (67.95% versus 52.33%), and receiving vildagliptin/metformin fixed DC versus free DC (70.69% versus 55.42%). Multivariate logistic regression analysis indicated that disease duration ( P < 0.0001), baseline HbA1c ( P < 0.0001), and DC type ( P = 0.0103) had significant effects on drug effectiveness. Vildagliptin plus metformin appeared as an effective treatment option for patients with T2DM in clinical practice settings in Korea.

  1. Blister Packaging Medication to Increase Treatment Adherence and Clinical Response: Impact on Suicide-related Morbidity and Mortality

    DTIC Science & Technology

    2011-09-01

    Veterans Affairs · Employee Education System’s Evidence-Based Interventions for Suicidal Persons conference, Denver, CO, February 8, 2007. · Rudd, M. D...relationships on failed belongingness and perceived burdensomeness in returning combat Veterans. Presented at the International Association for...Betthauser, L. M. Veterans’ experiences of habituation to painful stimuli, perceived burdensomeness and failed belongingness . ·Presented at the American

  2. Bacterial plaque colonization around dental implant surfaces.

    PubMed

    Covani, Ugo; Marconcini, Simone; Crespi, Roberto; Barone, Antonio

    2006-09-01

    To examine the distribution of bacteria into the internal and external surfaces of failed implants using histologic analysis. There were 10 failed pure titanium and 5 failed hydroxyapatite-coated titanium implants consecutively removed various years after their placement. Criteria for fixture removal were peri-implant radiolucency and clinical mobility. The mobile fixtures were retrieved with the patients under local anesthesia. Fixtures were removed maintaining the abutments with the aim to observe the bacterial infiltration at the level of abutment/implant interface and on the implant surface. A thin radiolucent space was always present around all the failed implants. The abutments screws were tightly secured in all clinical cases. The bacterial cells were composed of cocci and filaments, which were adherent to the implant surface with an orientation perpendicular to the long axis of the implant. All the specimens included in this study showed bacteria at the level of implant/abutment interface. Histologic analysis at the level of abutment/implant interface in 2-stage implants identified heavy bacterial colonization. These findings appear to support those studies showing bacteria penetration at the level of the micro-gap, which can legitimate the hypothesis that the micro-gap at the bone level could present a risk for bone loss caused by bacterial colonization.

  3. Salvage Percutaneous Vertebral Augmentation Using Polymethyl Methacrylate in Patients with Failed Interbody Fusion.

    PubMed

    Yun, Dong-Ju; Hwang, Byeong-Wook; Oh, Hyeong-Seok; Kim, Jin-Sung; Jeon, Sang-Hyeop; Lee, Sang-Ho

    2016-11-01

    Percutaneous vertebral augmentation with cement is used as a salvage procedure for failed instrumentation. Few studies have reported the use of this procedure for failed anterior lumbar fusion in elderly patients with osteoporosis and other complicated diseases who have undergone a previous major operation. Between January 2007 and December 2015, the clinical and radiographic results of 8 patients with osteoporosis who showed subsidence and migration of the implant after an initial operation were examined. After the development of implant failure, the patients underwent vertebral augmentation with polymethyl methacrylate. Mean patient age was 73.4 years (range, 67-78 years), and mean bone mineral density was -2.96 (range, -2.1 to -3.8). The mean radiologic follow-up period between augmentation and the last follow-up examination was 16 months (range, 3-38 months). Although the subjective clinical outcome was not satisfying to the patients, no loss of correction, fractures, or screw loosening occurred during the follow-up period. The injection of cement around the instrument might help to stabilize it by providing strength to the axis and preventing further loosening. This salvage procedure could be an alternative in the management of cases with failed interbody fusion. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Cryopreserved embryo transfer: adjacent or non-adjacent to failed fresh long GnRH-agonist protocol IVF cycle.

    PubMed

    Volodarsky-Perel, Alexander; Eldar-Geva, Talia; Holzer, Hananel E G; Schonberger, Oshrat; Reichman, Orna; Gal, Michael

    2017-03-01

    The optimal time to perform cryopreserved embryo transfer (CET) after a failed oocyte retrieval-embryo transfer (OR-ET) cycle is unknown. Similar clinical pregnancy rates were recently reported in immediate and delayed CET, performed after failed fresh OR-ET, in cycles with the gonadotrophin-releasing hormone (GnRH) antagonist protocol. This study compared outcomes of CET performed adjacently (<50 days, n = 67) and non-adjacently (≥50 to 120 days, n = 62) to the last OR-day of cycles with the GnRH agonist down-regulation protocol. Additional inclusion criteria were patients' age 20-38 years, the transfer of only 1-2 cryopreserved embryos, one treatment cycle per patient and artificial preparation for CET. Significantly higher implantation, clinical pregnancy and live birth rates were found in the non-adjacent group than in the adjacent group: 30.5% versus 11.3% (P = 0.001), 41.9% versus 17.9% (P = 0.003) and 32.3% versus 13.4% (P = 0.01), respectively. These results support the postponement of CET after a failed OR-ET for at least one menstrual cycle, when a preceding long GnRH-agonist protocol is used. Copyright © 2016 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  5. Preoperative Anemia Is Associated With Failure of Open Debridement Polyethylene Exchange in Acute and Acute Hematogenous Prosthetic Joint Infection.

    PubMed

    Swenson, Richard D; Butterfield, James A; Irwin, Timothy J; Zurlo, John J; Davis, Charles M

    2018-06-01

    Acute and acute hematogenous prosthetic joint infections (PJIs) are often treated with open debridement and polyethylene exchange (ODPE) in an effort to save the prosthesis, decrease morbidity, and reduce costs. However, failure of ODPE may compromise a subsequent 2-stage treatment. The purpose of this study is to identify patient factors that impact the success of ODPE for acute and acute hematogenous PJIs. A retrospective review examined comorbidities, preoperative laboratory values, and patient history for patients with successful and failed ODPE treatment for acute perioperative or acute hematogenous periprosthetic hip or knee joint infections. Successful treatment was defined as retaining a well-fixed implant without the need for additional surgery for a minimum of 6-month follow-up with or without lifelong oral maintenance antibiotics. Fifty-three of 72 patients (73.6%) underwent successful ODPE. Of the 19 failures, 14 completed 2-stage revision with one subsequent known failure for recurrent infection. Patients with a Staphylococcus aureus infection were more likely to fail ODPE (48.3% vs 11.6%, P = .0012, odds ratio 7.1, 95% confidence interval 2.3-25.3). Patients with a preoperative hematocrit ≤32.1 were also more likely to fail ODPE (55% vs 16%, P = .0013, odds ratio 6.7, 95% confidence interval 2.2-22.4). When neither risk factor was present, 97.1% of PJIs were successfully treated with ODPE. S aureus infection and preoperative hematocrit ≤32.1 are independent risk factors for ODPE failure. ODPE is a safe alternative to 2-stage revision in patients without preoperative anemia and without S aureus infection. Two-thirds of patients with a failed ODPE were successfully treated with a 2-stage reimplantation. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Effects of 7-day repeated treatment with the 5-HT2A inverse agonist/antagonist pimavanserin on methamphetamine vs. food choice in male rhesus monkeys.

    PubMed

    Banks, Matthew L

    2016-08-01

    Preclinical drug vs. food choice is an emerging group of drug self-administration procedures that have shown predictive validity to clinical drug addiction. Emerging data suggest that serotonin (5-HT)2A receptors modulate mesolimbic dopamine function, such that 5-HT2A antagonists blunt the abuse-related neurochemical effects of monoamine transporter substrates, such as amphetamine or methamphetamine. Whether subchronic 5-HT2A antagonist treatment attenuates methamphetamine reinforcement in any preclinical drug self-administration procedure is unknown. The study aim was therefore to determine 7-day treatment effects with the 5-HT2A inverse agonist/antagonist pimavanserin on methamphetamine vs. food choice in monkeys. Behavior was maintained under a concurrent schedule of food delivery (1g pellets, fixed-ratio 100 schedule) and intravenous methamphetamine injections (0-0.32 mg/kg/injection, fixed-ratio 10 schedule) in male rhesus monkeys (n=3). Methamphetamine choice dose-effect functions were determined daily before and during 7-day repeated pimavanserin (1.0-10mg/kg/day, intramuscular) treatment periods. Under control conditions, increasing methamphetamine doses resulted in a corresponding increase in methamphetamine vs. food choice. Repeated pimavanserin administration failed to attenuate methamphetamine choice and produce a reciprocal increase in food choice in any monkey up to doses (3.2-10mg/kg) that suppressed rates of operant responding primarily during components where behavior was maintained by food pellets. Repeated 5-HT2A receptor inverse agonist/antagonist treatment did not attenuate methamphetamine reinforcement under a concurrent schedule of intravenous methamphetamine and food presentation in nonhuman primates. Overall, these results do not support the therapeutic potential of 5-HT2A inverse agonists/antagonists as candidate medications for methamphetamine addiction. Copyright © 2016 The Author(s). Published by Elsevier Ireland Ltd.. All rights reserved.

  7. Treatment of Complex Regional Pain Syndrome (CRPS) using low dose naltrexone (LDN).

    PubMed

    Chopra, Pradeep; Cooper, Mark S

    2013-06-01

    Complex Regional Pain Syndrome (CRPS) is a neuropathic pain syndrome, which involves glial activation and central sensitization in the central nervous system. Here, we describe positive outcomes of two CRPS patients, after they were treated with low-dose naltrexone (a glial attenuator), in combination with other CRPS therapies. Prominent CRPS symptoms remitted in these two patients, including dystonic spasms and fixed dystonia (respectively), following treatment with low-dose naltrexone (LDN). LDN, which is known to antagonize the Toll-like Receptor 4 pathway and attenuate activated microglia, was utilized in these patients after conventional CRPS pharmacotherapy failed to suppress their recalcitrant CRPS symptoms.

  8. Microscopical analysis of synovial fluid wear debris from failing CoCr hip prostheses

    NASA Astrophysics Data System (ADS)

    Ward, M. B.; Brown, A. P.; Cox, A.; Curry, A.; Denton, J.

    2010-07-01

    Metal on metal hip joint prostheses are now commonly implanted in patients with hip problems. Although hip replacements largely go ahead problem free, some complications can arise such as infection immediately after surgery and aseptic necrosis caused by vascular complications due to surgery. A recent observation that has been made at Manchester is that some Cobalt Chromium (CoCr) implants are causing chronic pain, with the source being as yet unidentified. This form of replacement failure is independent of surgeon or hospital and so some underlying body/implant interface process is thought to be the problem. When the synovial fluid from a failed joint is examined particles of metal (wear debris) can be found. Transmission Electron Microscopy (TEM) has been used to look at fixed and sectioned samples of the synovial fluid and this has identified fine (< 100 nm) metal and metal oxide particles within the fluid. TEM EDX and Electron Energy Loss Spectroscopy (EELS) have been employed to examine the composition of the particles, showing them to be chromium rich. This gives rise to concern that the failure mechanism may be associated with the debris.

  9. Legal semantics. Nurses and non-surgical abortions.

    PubMed

    Rae, K

    1981-02-26

    A 1980 law was confirmed by the House of Lords majority which allows nurses to participate in the nonsurgical prostaglandin termination of pregnancy. Nurses are acting under written instructions of a doctor when carrying out the procedure, although they also terminate the pregnancy. A nurse is now in danger of liability litigation if she fails at any stage of the termination to perform successfully. The majority decision made the two words "termination" and "treatment" of pregnancy synonymous. Nurses are to act in a ministerial capacity and on doctors' orders. Doctors are to share in any liability if negligence should occur. The question remains: will they? The procedure includes the following: attachment of the catheter to the prostaglandin pump; switching on of pump; insertion of a cannula into the vein; attachment and commencement of the oxytocin intravenous infusion; monitoring of the patient's observations; adjustment of the flow rates of both infusions; and, discontinuation of the process once the fetus is discharged or a fixed period has expired after which the operation is considered to have failed (usually 30 hours).

  10. In vitro evaluation of the flexural properties of All-on-Four provisional fixed denture base resin partially reinforced with fibers.

    PubMed

    Li, Bei Bei; Xu, Jia Bin; Cui, Hong Yan; Lin, Ye; Di, Ping

    2016-01-01

    The aim of this study was to assess the effects of partial carbon or glass fiber reinforcement on the flexural properties of All-on-Four provisional fixed denture base resin. The carbon or glass fibers were woven (3% by weight) together in three strands and twisted and tightened between the two abutments in a figure-of-"8" pattern. Four types of specimens were fabricated for the three-point loading test. The interface between the denture base resin and fibers was examined using scanning electron microscopy (SEM). Reinforcement with carbon or glass fibers between two abutments significantly increased the flexural strength and flexural modulus. SEM revealed relatively continuous contact between the fibers and acrylic resin. The addition of carbon or glass fibers between two abutments placed on All-on-Four provisional fixed denture base resin may be clinically effective in preventing All-on-Four denture fracture and can provide several advantages for clinical use.

  11. Analysis of formalin-fixed, paraffin-embedded (FFPE) tissue via proteomic techniques and misconceptions of antigen retrieval.

    PubMed

    O'Rourke, Matthew B; Padula, Matthew P

    2016-01-01

    Since emerging in the late 19(th) century, formaldehyde fixation has become a standard method for preservation of tissues from clinical samples. The advantage of formaldehyde fixation is that fixed tissues can be stored at room temperature for decades without concern for degradation. This has led to the generation of huge tissue banks containing thousands of clinically significant samples. Here we review techniques for proteomic analysis of formalin-fixed, paraffin-embedded (FFPE) tissue samples with a specific focus on the methods used to extract and break formaldehyde crosslinks. We also discuss an error-of-interpretation associated with the technique known as "antigen retrieval." We have discovered that this term has been mistakenly applied to two disparate molecular techniques; therefore, we argue that a terminology change is needed to ensure accurate reporting of experimental results. Finally, we suggest that more investigation is required to fully understand the process of formaldehyde fixation and its subsequent reversal.

  12. Pharmacokinetics and pharmacodynamics of sofosbuvir and ledipasvir for the treatment of hepatitis C.

    PubMed

    Cuenca-Lopez, Francisca; Rivero, Antonio; Rivero-Juárez, Antonio

    2017-01-01

    The sofosbuvir (SOF) plus ledipasvir (LDV) fixed dose combination is the first direct action antiviral (DAA) single-treatment regimen (STR) to be commercialized. It is approved for the treatment of Hepatitis C virus (HCV) genotypes 1,3,4,5 and 6. Following approval in 2014, new pharmacokinetics and pharmacodynamics data were reported, which led to important clinical applications. Areas covered: This article reviews the pharmacokinetic and pharmacodynamic properties of the SOF/LDV fixed dose combination for the treatment of HCV. The topics covered include data regarding the drug´s absorption, distribution, metabolism and excretion and antiviral activity strategies such as the clinical dose selection and treatment duration. Expert opinion: The SOF/LDV fixed dose combination has good pharmacological properties that lead to a high sustained virological response after 12 or 24 weeks of treatment; there is minimal interference with other drugs or associated renal or hepatic impairment, such that dose adjustment is not necessary.

  13. Five-year clinical evaluation of zirconia-based bridges in patients in UK general dental practices.

    PubMed

    Burke, F J T; Crisp, R J; Cowan, A J; Lamb, J; Thompson, O; Tulloch, N

    2013-11-01

    This study reported the results at 5 years of fixed-fixed all-ceramic bridges, constructed in a yttria oxide stabilized tetragonal zirconium oxide polycrystal (Y-TZP) substructure, placed in adult patients in UK general dental practices. Four UK general dental practitioners recruited patients who required fixed bridgework and, after obtaining informed written consent, appropriate clinical and radiographic assessments were completed. The teeth were prepared and bridges constructed in accordance with the manufacturer's instructions. Each bridge was reviewed annually within 3 months of the anniversary of its placement by a calibrated examiner, together with the clinician who had placed the restoration, using modified USPHS criteria. Of the 41 bridges originally placed, 33 bridges were examined at 5 years. All Y-TZP frameworks were intact and no bridge retainers had debonded. Eight chipping fractures in the veneering ceramic were noted over the 5-year period. In five cases the patients were unaware of these and these cases were polished. Of the remaining three cases, in one a repair was attempted but was unsuccessful, but the bridge remained in satisfactory service. However, in the case involving a chipping fracture of the mesial-incisal angle of a central incisor, it was considered that replacement of the bridge was necessary. 97% (n=32) of the 33 Lava Y-TZP fixed-fixed bridges, evaluated in patients attending UK general dental practices, were found to be performing satisfactorily. The use of Y-TZP frameworks holds promise. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. The Typical General Aviation Aircraft

    NASA Technical Reports Server (NTRS)

    Turnbull, Andrew

    1999-01-01

    The reliability of General Aviation aircraft is unknown. In order to "assist the development of future GA reliability and safety requirements", a reliability study needs to be performed. Before any studies on General Aviation aircraft reliability begins, a definition of a typical aircraft that encompasses most of the general aviation characteristics needs to be defined. In this report, not only is the typical general aviation aircraft defined for the purpose of the follow-on reliability study, but it is also separated, or "sifted" into several different categories where individual analysis can be performed on the reasonably independent systems. In this study, the typical General Aviation aircraft is a four-place, single engine piston, all aluminum fixed-wing certified aircraft with a fixed tricycle landing gear and a cable operated flight control system. The system breakdown of a GA aircraft "sifts" the aircraft systems and components into five categories: Powerplant, Airframe, Aircraft Control Systems, Cockpit Instrumentation Systems, and the Electrical Systems. This breakdown was performed along the lines of a failure of the system. Any component that caused a system to fail was considered a part of that system.

  15. Elementary Students' Scientific Epistemological Beliefs in Relation to Socio-Economic Status and Gender

    NASA Astrophysics Data System (ADS)

    Ozkal, Kudret; Tekkaya, Ceren; Sungur, Semra; Cakiroglu, Jale; Cakiroglu, Erdinc

    2011-03-01

    This study investigated students' scientific epistemological beliefs in relation to socio-economic status (SES) and gender. Data were obtained from 1,152 eight grade Turkish elementary school students using Scientific Epistemological Beliefs instrument. Canonical correlation analysis indicated that students with a working mother and educated parents as well as greater number of books at home together with a separate study room are more likely to have tentative views and less likely to have fixed views about science compared to students with unemployed mother, uneducated parents, less books at home, and no separate study room. Generally, results revealed while family SES correlated positively with tentative views, it was negatively associated with fixed views, implying that students from high SES family were more likely to believe that knowledge is uncertain and not handed down by authority compared to students from low SES family. This study, however, failed to indicate any relationship between father work-status, buying daily newspaper and epistemological beliefs. In addition, Multivariate Analysis of Variance indicated that boys more likely to have tentative beliefs compared to girls.

  16. Elementary Students' Scientific Epistemological Beliefs in Relation to Socio-Economic Status and Gender

    NASA Astrophysics Data System (ADS)

    Ozkal, Kudret; Tekkaya, Ceren; Sungur, Semra; Cakiroglu, Jale; Cakiroglu, Erdinc

    2010-11-01

    This study investigated students’ scientific epistemological beliefs in relation to socio-economic status (SES) and gender. Data were obtained from 1,152 eight grade Turkish elementary school students using Scientific Epistemological Beliefs instrument. Canonical correlation analysis indicated that students with a working mother and educated parents as well as greater number of books at home together with a separate study room are more likely to have tentative views and less likely to have fixed views about science compared to students with unemployed mother, uneducated parents, less books at home, and no separate study room. Generally, results revealed while family SES correlated positively with tentative views, it was negatively associated with fixed views, implying that students from high SES family were more likely to believe that knowledge is uncertain and not handed down by authority compared to students from low SES family. This study, however, failed to indicate any relationship between father work-status, buying daily newspaper and epistemological beliefs. In addition, Multivariate Analysis of Variance indicated that boys more likely to have tentative beliefs compared to girls.

  17. Fixed-head star tracker attitude updates on the Hubble Space Telescope

    NASA Technical Reports Server (NTRS)

    Nadelman, Matthew S.; Karl, Jeffrey B.; Hallock, Lou

    1994-01-01

    The Hubble Space Telescope (HST) was launched in April 1990 to begin observing celestial space to the edge of the universe. National Aeronautics and Space Administration (NASA) standard fixed-head star trackers (FHST's) are used operationally onboard the HST to regularly adjust ('update') the spacecraft attitude before the acquisition of guide stars for science observations. During the first 3 months of the mission, the FHST's updated the spacecraft attitude successfully only 85 percent of the time. During the other periods, the trackers were unable to find the selected stars -- either they failed to find any star, or worse, they selected incorrect stars and produced erroneous attitude updates. In July 1990, the HST project office at Goddard Space Flight Center (GSFC) requested that Computer Sciences Corporation (CSC) form an investigative 'tiger' team to examine these FHST update failures. This paper discusses the work of the FHST tiger team, describes the investigations that led the team to identify the sources of the errors, and defines the solutions that were subsequently developed, which ultimately increased the success rate of FHST updates to approximately 98 percent.

  18. Bone preserving techniques for explanting the well-fixed cemented acetabular component.

    PubMed

    Stevens, Jarrad; Macpherson, Gavin; Howie, Colin

    2018-06-01

    Removal of a well-fixed, cemented acetabular component at the time of revision hip surgery can be complex. It is essential to remove the implant and cement mantle in a timely fashion while preserving bone stock and osseous integrity. The biomechanical properties of polymethylmethacrylate cement and polyethylene can be utilised to aid with the removal of well cemented implants which are often harder than the surrounding bone. While removal of loose components may be relatively straightforward, the challenge for the revision arthroplasty surgeon often involves the removal of well-fixed implants. Here, we present three established techniques for the removal of a well-fixed cemented acetabular component and one novel modification we have described before. We collate and review four techniques for removing well-fixed cemented acetabular implants that utilise the different biomechanical properties of bone cement and polyethylene. These techniques are illustrated with a photographic series utilising saw bones. A step-by-step approach to our new technique is shown in photographs, both in the clinical setting and with a "Sawbone". This is accompanied by a clinical video that details the surgical technique in its entirety. These techniques utilise different biomechanical principles to extract the acetabular component. Each technique has advantages and disadvantages. Our new technique is a simplification of a previously published extraction manoeuvre that utilises tensile force between cement and the implant to remove the polyethylene cup. This is a safe and reproducible technique in patients with a well-fixed cemented acetabular implant. Understanding the biomechanical properties of polymethylmethacrylate bone cement and polyethylene can aid in the safe removal of a well-fixed cemented acetabular component in revision hip surgery. The optimal technique for removal of a cemented acetabular component varies depending on a number of patient and implant factors. This summary of the available techniques will be of interest to revision arthroplasty surgeons.

  19. Ten years of clinical experience in the use of fixed-pressure versus programmable valves: a retrospective study of 159 patients.

    PubMed

    Mpakopoulou, Maria; Brotis, Alexandros G; Gatos, Haralampos; Paterakis, Konstantinos; Fountas, Kostas N

    2012-01-01

    The aim of this study was to present our 10-year experience with the use of fixed-pressure and programmable valves in the treatment of adult patients requiring cerebrospinal fluid (CSF) diversion. Patients (n = 159; 89 male and 70 female) suffering from hydrocephalus of various causes underwent CSF shunt implantation. Forty fixed-pressure and 119 programmable valves were initially implanted. The observed revision rate was 40% in patients with fixed-pressure valves. In 20% of these patients, a revision due to valve mechanism malfunction was undertaken, and the initial valve was replaced with a programmable one. The revision rate in the adjustable-pressure valve subgroup was 20%. The infection rate for the fixed-pressure and programmable valve subgroups were 3%, and 1.7%, respectively. Similarly, subdural fluid collections were noticed in 17% and 4% of patients with fixed-pressure valves and programmable valves, respectively. The revision and over-drainage rates were significantly lower when using programmable valves, and thus, this type of valve is preferred whenever CSF has to be diverted.

  20. Comparison of three-implant-supported fixed dentures and two-implant-retained overdentures in the edentulous mandible: a pilot study of treatment efficacy and patient satisfaction.

    PubMed

    De Kok, Ingeborg J; Chang, Kuang-Han; Lu, Tsui-Shan; Cooper, Lyndon F

    2011-01-01

    The mandibular two-implant overdenture has been shown to be a highly successful treatment. However, overdenture patients who desire a fixed prosthesis may not be satisfied with a removable overdenture. This prospective study sought to compare prosthetic outcomes, patient satisfaction, and survival rates of implants between two-implant-supported overdentures (IODs) and three-implant-supported fixed dentures (ISFDs). Twenty completely edentulous patients were randomly and equally assigned to two groups. New conventional complete dentures were made, and the mandibular denture was used as a surgical guide during implant placement. Implants were placed in one stage, followed by a mandibular denture soft reline (provisional loading). Ball attachments were inserted at 8 weeks, and ISFDs were delivered at 16 weeks. IODs were connected to the attachments at 8 weeks, using each patients's existing denture. The definitive ISFDs were fabricated using computer-aided design/computer-assisted manufacture milled titanium frameworks and acrylic resin base and teeth. Patient satisfaction and panoramic radiographs were investigated at 6 and 12 months. Both treatments had significant and positive effects on patient satisfaction and quality of life. None of the 50 implants placed had failed at 12 months of follow-up; therefore, the implant survival rate was 100%. Prosthetic complications were generally rare and easily manageable. Both the treatment modalities-the ISFD supported by three implants and the IOD supported by two implants-significantly and similarly improved patient satisfaction and oral health-related quality of life, and prosthetic complications were relatively rare for both treatments. Three implants can be used to support a mandibular fixed prosthesis; however, a longer observation period is needed to validate this treatment modality.

  1. Comparison of point counts and territory mapping for detecting effects of forest management on songbirds

    USGS Publications Warehouse

    Newell, Felicity L.; Sheehan, James; Wood, Petra Bohall; Rodewald, Amanda D.; Buehler, David A.; Keyser, Patrick D.; Larkin, Jeffrey L.; Beachy, Tiffany A.; Bakermans, Marja H.; Boves, Than J.; Evans, Andrea; George, Gregory A.; McDermott, Molly E.; Perkins, Kelly A.; White, Matthew; Wigley, T. Bently

    2013-01-01

    Point counts are commonly used to assess changes in bird abundance, including analytical approaches such as distance sampling that estimate density. Point-count methods have come under increasing scrutiny because effects of detection probability and field error are difficult to quantify. For seven forest songbirds, we compared fixed-radii counts (50 m and 100 m) and density estimates obtained from distance sampling to known numbers of birds determined by territory mapping. We applied point-count analytic approaches to a typical forest management question and compared results to those obtained by territory mapping. We used a before–after control impact (BACI) analysis with a data set collected across seven study areas in the central Appalachians from 2006 to 2010. Using a 50-m fixed radius, variance in error was at least 1.5 times that of the other methods, whereas a 100-m fixed radius underestimated actual density by >3 territories per 10 ha for the most abundant species. Distance sampling improved accuracy and precision compared to fixed-radius counts, although estimates were affected by birds counted outside 10-ha units. In the BACI analysis, territory mapping detected an overall treatment effect for five of the seven species, and effects were generally consistent each year. In contrast, all point-count methods failed to detect two treatment effects due to variance and error in annual estimates. Overall, our results highlight the need for adequate sample sizes to reduce variance, and skilled observers to reduce the level of error in point-count data. Ultimately, the advantages and disadvantages of different survey methods should be considered in the context of overall study design and objectives, allowing for trade-offs among effort, accuracy, and power to detect treatment effects.

  2. A simple quantitative diagnostic alternative for MGMT DNA-methylation testing on RCL2 fixed paraffin embedded tumors using restriction coupled qPCR.

    PubMed

    Pulverer, Walter; Hofner, Manuela; Preusser, Matthias; Dirnberger, Elisabeth; Hainfellner, Johannes A; Weinhaeusel, Andreas

    2014-01-01

    MGMT promoter methylation is associated with favorable prognosis and chemosensitivity in glioblastoma multiforme (GBM), especially in elderly patients. We aimed to develop a simple methylation-sensitive restriction enzyme (MSRE)-based quantitative PCR (qPCR) assay, allowing the quantification of MGMT promoter methylation. DNA was extracted from non-neoplastic brain (n = 24) and GBM samples (n = 20) upon 3 different sample conservation conditions (-80 °C, formalin-fixed and paraffin-embedded (FFPE); RCL2-fixed). We evaluated the suitability of each fixation method with respect to the MSRE-coupled qPCR methylation analyses. Methylation data were validated by MALDITOF. qPCR was used for evaluation of alternative tissue conservation procedures. DNA from FFPE tissue failed reliable testing; DNA from both RCL2-fixed and fresh frozen tissues performed equally well and was further used for validation of the quantitative MGMT methylation assay (limit of detection (LOD): 19.58 pg), using individual's undigested sample DNA for calibration. MGMT methylation analysis in non-neoplastic brain identified a background methylation of 0.10 ± 11% which we used for defining a cut-off of 0.32% for patient stratification. Of GBM patients 9 were MGMT methylationpositive (range: 0.56 - 91.95%), and 11 tested negative. MALDI-TOF measurements resulted in a concordant classification of 94% of GBM samples in comparison to qPCR. The presented methodology allows quantitative MGMT promoter methylation analyses. An amount of 200 ng DNA is sufficient for triplicate analyses including control reactions and individual calibration curves, thus excluding any DNA qualityderived bias. The combination of RCL2-fixation and quantitative methylation analyses improves pathological routine examination when histological and molecular analyses on limited amounts of tumor samples are necessary for patient stratification.

  3. Translation failure and medical reversal: Two sides to the same coin.

    PubMed

    Prasad, Vinay

    2016-01-01

    Translation failure occurs when the results of preclinical, observational and/or early phase studies fail to predict the results of well done (i.e. appropriately controlled, adequately powered, and properly conducted) phase III or randomised clinical trials. Some failures occur when promising basic science findings fail to replicate in human studies, while others happen when promising uncontrolled trial data show an exaggerated effect that vanishes in the setting of a randomised trial. Medical reversals occur when the results of preclinical, observational and/or early phase studies fail to predict the results of subsequent randomized clinical trials, but the practice has already gained widespread acceptance. Oncologic examples include bevacizumab and the use of autologous stem cell transplant in metastatic breast cancer. In a well-intentioned effort to reduce the rate of translation failure, oncologists must be careful that changes to regulatory processes and clinical trial design do not actually work to increase the approval of ineffective compounds. By trying to cure translation failure, we should be careful to avoid medical reversal. The rise of surrogate end-points and role of hard-wired bias in oncology trials suggest that we may be currently ignoring the simple fact that translation failure and medical reversal are two sides to the same coin. Published by Elsevier Ltd.

  4. Current trends of reproductive immunology practices in in vitro fertilization (IVF) - a first world survey using IVF-Worldwide.com.

    PubMed

    Kwak-Kim, Joanne; Han, Ae Ra; Gilman-Sachs, Alice; Fishel, Simon; Leong, Milton; Shoham, Zeev

    2013-01-01

    Reproductive immunology has evolved from basic research studies to clinical applications. In this study, we aim to investigate the actual application of reproductive immunology concepts and findings in clinical reproductive medicine such as recurrent pregnancy losses (RPL), repeated implantation failures (RIF), and failed in vitro fertilization (IVF) cycles. A web-based survey was performed on IVF-Worldwide.com. Collected data were analyzed by the computerized software. A significant proportion of physicians recommend thrombophilia workups (86%), parental genetic study (79%), and immunologic evaluations (69%) to IVF candidates who have a history of RPL or chemical pregnancy losses. IVF physicians consider an immunologic workup when patients have two (30%) or three (21%) failed IVF cycles. Assays for anticardiolipin antibody, lupus anticoagulant, thyroid peroxidase antibody, and antinuclear antibody are the four most commonly ordered immunologic tests for RPL (88, 84, 50, 47% each) and RIF (68, 63, 38, 38% each). Cellular immune evaluations, such as NK assay, human leukocyte antigen study, Th1/Th2 study or immunophenotype assay, are less commonly ordered. Reproductive immunology principles have been applied to the clinical management of RPL, RIF, and failed IVF cycles, and a significant proportion of IVF physicians acknowledge the importance of immunologic alterations with reproductive outcomes. © 2012 John Wiley & Sons A/S.

  5. How Hedstrom files fail during clinical use? A retrieval study based on SEM, optical microscopy and micro-XCT analysis.

    PubMed

    Zinelis, Spiros; Al Jabbari, Youssef S

    2018-05-01

    This study was conducted to evaluate the failure mechanism of clinically failed Hedstrom (H)-files. Discarded H-files (n=160) from #8 to #40 ISO sizes were collected from different dental clinics. Retrieved files were classified according to their macroscopic appearance and they were investigated under scanning electron microscopy (SEM) and X-ray micro-computed tomography (mXCT). Then the files were embedded in resin along their longitudinal axis and after metallographic grinding and polishing, studied under an incident light microscope. The macroscopic evaluation showed that small ISO sizes (#08-#15) failed by extensive plastic deformation, while larger sizes (≥#20) tended to fracture. Light microscopy and mXCT results coincided showing that unused and plastically deformed files were free of internal defects, while fractured files demonstrate the presence of intense cracking in the flute region. SEM analysis revealed the presence of striations attributed to the fatigue mechanism. Secondary cracks were also identified by optical microscopy and their distribution was correlated to fatigue under bending loading. Experimental results demonstrated that while overloading of cutting instruments is the predominating failure mechanism of small file sizes (#08-#15), fatigue should be considered the fracture mechanism for larger sizes (≥#20).

  6. Optical redox imaging of fixed unstained tissue slides to identify biomarkers for breast cancer diagnosis/prognosis: feasibility study

    NASA Astrophysics Data System (ADS)

    Xu, He N.; Tchou, Julia; Li, Yusheng; Feng, Min; Zhang, Paul; Quinn, William J.; Baur, Joseph A.; Li, Lin Z.

    2018-02-01

    We previously showed that optical redox imaging (ORI) of snap-frozen breast biopsies by the Chance redox scanner readily discriminates cancer from normal tissue. Moreover, indices of redox heterogeneity differentiate among tumor xenografts with different metastatic potential. These observations suggest that ORI of fluorescence of NADH and oxidized flavoproteins (Fp) may provide diagnostic/prognostic value for clinical applications. In this work, we investigate whether ORI of formalin-fixed-paraffin-embedded (FFPE) unstained clinical tissue slides of breast tumors is feasible and comparable to ORI of snap-frozen tumors. If ORI of FFPE is validated, it will enhance the versatility of ORI as a novel diagnostic/prognostic assay as FFPE samples are readily available. ORI of fixed tissue slides was performed using a fluorescence microscope equipped with a precision automated stage and appropriate optical filters. We developed a vignette correction algorithm to remove the tiling effect of stitched-images. The preliminary data from imaging fixed slides of breast tumor xenografts showed intratumor redox heterogeneity patterns similar to that of the frozen tissues imaged by the Chance redox scanner. From ORI of human breast tissue slides we identified certain redox differences among normal, ductal carcinoma in situ, and invasive carcinoma. We found paraformaldehyde fixation causes no change in NADH signals but enhances Fp signals of fresh muscle fibers. We also investigated the stability of the fluorescence microscope and reproducibility of tissue slide fluorescence signals. We plan to validate the diagnostic/prognostic value of ORI using clinically annotated breast cancer sample set from patients with long-term follow-up data.

  7. Treatment adherence and real-life effectiveness of topical therapy in patients with mild or moderate psoriasis: uptake of scientific evidence in clinical practice and dermatologists' preferences for alternative treatment options.

    PubMed

    Neri, L; Miracapillo, A

    2015-02-01

    Topical corticosteroids and the vitamin D analogue calcipotriol are the cornerstone of therapy for patients with mild-to-moderate plaque psoriasis. Lack of patients' adherence leads to suboptimal effectiveness of topical therapy in real-life practice. The fixed combination betamethasone/calcipotriol gel is more effective and safe than the administration of single components and may enhance patients' adherence. We aimed at evaluating the pattern of care and dermatologists' expert opinion toward the available topical treatments for the management of mild-to-moderate psoriasis in Italy. We enrolled 242 Italian dermatologists and collected information related to their practice pattern and opinion toward available topical treatments with a face-to-face structured interview. We evaluated dermatologists' ratings of therapy with 16 items tapping their opinion toward the relevance and satisfaction toward 8 therapy attributes in clinical practices which tapped aspects of real-life effectiveness, adherence promotion, toxicity, convenience of use. Ratings occurred along a 10-point scale. We compared single-attribute and weighted overall therapy ratings across alternative treatment options with random-intercept linear models to account for ratings clustering within dermatologists. There was a wide variation in practice patterns: 1/3 of dermatologist had seen more than 30 patients with psoriasis while around 1/4 had seen less than 10 patients. The fixed combination betamethasone/calcipotriol gel was considered superior to monotherapies in all the eight attributes considered which tapped aspects of real-life effectiveness, adherence promotion, toxicity, convenience of use. Participant dermatologists' strongly preferred the fixed betamethasone/calcipotriol combination gel over both the fixed combination ointment formulation and corticosteroid or vitamin D analogues monotherapies. Such findings are in line with evidence from randomized controlled trials and few observational studies demonstrating superior clinical outcomes, quality of life, tolerability and lower risk of side effect in patients treated with the fixed combination of betamethasone/calcipotriol gel.

  8. In vivo recovery of factor VIII and factor IX: intra- and interindividual variance in a clinical setting.

    PubMed

    Björkman, S; Folkesson, A; Berntorp, E

    2007-01-01

    In vivo recovery (IVR) is traditionally used as a parameter to characterize the pharmacokinetic properties of coagulation factors. It has also been suggested that dosing of factor VIII (FVIII) and factor IX (FIX) can be adjusted according to the need of the individual patient, based on an individually determined IVR value. This approach, however, requires that the individual IVR value is more reliably representative for the patient than the mean value in the population, i.e. that there is less variance within than between the individuals. The aim of this investigation was to compare intra- and interindividual variance in IVR (as U dL1 per U kg1) for FVIII and plasma-derived FIX in a cohort of non-bleeding patients with haemophilia. The data were collected retrospectively from six clinical studies, yielding 297 IVR determinations in 50 patients with haemophilia A and 93 determinations in 13 patients with haemophilia B. For FVIII, the mean variance within patients exceeded the between-patient variance. Thus, an individually determined IVR value is apparently no more informative than an average, or population, value for the dosing of FVIII. There was no apparent relationship between IVR and age of the patient (1.5-67 years). For FIX, the mean variance within patients was lower than the between-patient variance, and there was a significant positive relationship between IVR and age (13-69 years). From these data, it seems probable that using an individual IVR confers little advantage in comparison to using an age-specific population mean value. Dose tailoring of coagulation factor treatment has been applied successfully after determination of the entire single-dose curve of FVIII:C or FIX:C in the patient and calculation of the relevant pharmacokinetic parameters. However, the findings presented here do not support the assumption that dosing of FVIII or FIX can be individualized on the basis of a clinically determined IVR value.

  9. Molecular detection of Coxiella burnetii from the formalin-fixed tissues of Q fever patients with acute hepatitis.

    PubMed

    Jang, Young-Rock; Shin, Yong; Jin, Choong Eun; Koo, Bonhan; Park, Se Yoon; Kim, Min-Chul; Kim, Taeeun; Chong, Yong Pil; Lee, Sang-Oh; Choi, Sang-Ho; Kim, Yang Soo; Woo, Jun Hee; Kim, Sung-Han; Yu, Eunsil

    2017-01-01

    Serologic diagnosis is one of the most widely used diagnostic methods for Q fever, but the window period in antibody response of 2 to 3 weeks after symptom onset results in significant diagnostic delay. We investigated the diagnostic utility of Q fever PCR from formalin-fixed liver tissues in Q fever patients with acute hepatitis. We reviewed the clinical and laboratory data in patients with Q fever hepatitis who underwent liver biopsy during a 17-year period, and whose biopsied tissues were available. We also selected patients who revealed granuloma in liver biopsy and with no Q fever diagnosis within the last 3 years as control. Acute Q fever hepatitis was diagnosed if two or more of the following clinical, serologic, or histopathologic criteria were met: (1) an infectious hepatitis-like clinical feature such as fever (≥ 38°C) with elevated hepatic transaminase levels; (2) exhibition of a phase II immunoglobulin G (IgG) antibodies titer by IFA of ≥ 1:128 in single determination, or a four-fold or greater rise between two separate samples obtained two or more weeks apart; (3) histologic finding of biopsy tissue showing characteristic fibrin ring granuloma. A total of 11 patients with acute Q fever hepatitis were selected and analyzed. Of the 11 patients, 3 (27%) had exposure to zoonotic risk factors and 7 (63%) met the serologic criteria. Granulomas with either circumferential or radiating fibrin deposition were observed in 10 cases on liver biopsy and in 1 case on bone marrow biopsy. 8 (73%) revealed positive Coxiella burnetii PCR from their formalin-fixed liver tissues. In contrast, none of 10 patients with alternative diagnosis who had hepatic granuloma revealed positive C. burnetii PCR from their formalin-fixed liver tissues. Q fever PCR from formalin-fixed liver tissues appears to be a useful adjunct for diagnosing Q fever hepatitis.

  10. Impact of Bruxism on Ceramic Defects in Implant-Borne Fixed Dental Prostheses: A Retrospective Study.

    PubMed

    Mikeli, Aikaterini; Walter, Michael H

    2016-01-01

    Ceramic veneer fracture is a frequent complication in implant-borne fixed restorations. The retrospective clinical study assesses the effect of bruxism on this complication. A sample of 507 implant-borne fixed units inserted between 1995 and 2011 in 144 patients were examined. Any detected veneer fractures were assigned to one of four groups according to extent and position. A hypothetical correlation between bruxism and ceramic veneer fractures was examined. Of 34 patients (23.6%) with at least one ceramic veneer fracture, 24 were bruxers (70%) and 10 were nonbruxers (30%) (P = .002). Bruxism may pose a risk for ceramic fractures.

  11. Clinical utility of azilsartan-chlorthalidone fixed combination in the management of hypertension.

    PubMed

    Shuster, Jerrica E; Bleske, Barry E; Dorsch, Michael P

    2012-01-01

    Azilsartan-chlorthalidone fixed combination is a new drug in the management of hypertension. Azilsartan has been shown to have greater blood pressure-lowering effects than other angiotensin-receptor blockers (ARBs), and the debate regarding the superiority of chlorthalidone over hydrochlorothiazide has been ongoing for years. The combination is unique because it is the first to partner an ARB with this, possibly more effective, diuretic. This review will address trials involving both components of this drug, as well as phase III trials involving the fixed-combination product. The article will also discuss the benefit of combination therapy in the treatment of hypertension.

  12. Clinical utility of azilsartan–chlorthalidone fixed combination in the management of hypertension

    PubMed Central

    Shuster, Jerrica E; Bleske, Barry E; Dorsch, Michael P

    2012-01-01

    Azilsartan–chlorthalidone fixed combination is a new drug in the management of hypertension. Azilsartan has been shown to have greater blood pressure-lowering effects than other angiotensin-receptor blockers (ARBs), and the debate regarding the superiority of chlorthalidone over hydrochlorothiazide has been ongoing for years. The combination is unique because it is the first to partner an ARB with this, possibly more effective, diuretic. This review will address trials involving both components of this drug, as well as phase III trials involving the fixed-combination product. The article will also discuss the benefit of combination therapy in the treatment of hypertension. PMID:22745562

  13. Positioning, labelling, and medical information control of co-artemether tablets (CPG 56697): a fixed novel combination of artemether and benflumetol. Novartis Co-Artemether International Development Team.

    PubMed

    Skelton-Stroud, P; Mull, R

    1998-01-01

    Coartemether is a fixed 1:6 ratio of artemether and lumefantrine (benflumetol), a joint development between Novartis Pharma and the Academy of Military Medical Sciences (Beijing, China). It is well tolerated and has a high efficacy against uncomplicated and drug resistant falciparum malaria by oral administration. The preclinical profile of coartemether revealed no prohibitive toxicological, teratogenic or mutagenic findings. No evidence of neurotoxicity was seen in oral preclinical studies. It shows a negative response to the induction of resistance and prevents recrudescence. Clinically, coartemether shows a rapid onset of antiparasitic action, resolution of symptoms, no clinical neurotoxicity and excellent parasite clearance.

  14. Maxillary rehabilitation using fixed and removable partial dentures with attachments: a clinical report.

    PubMed

    dos Santos Nunes Reis, José Maurício; da Cruz Perez, Luciano Elias; Alfenas, Bruna Fernandes Moreira; de Oliveira Abi-Rached, Filipe; Filho, João Neudenir Arioli

    2014-01-01

    Despite requiring dental crown preparation and possible root canal treatment, besides the difficulty of clinical and laboratory repairs, and financial burden, the association between fixed (FPD) and removable partial dentures (RPD) by means of attachments is an important alternative for oral rehabilitation, particularly when the use of dental implants and FPDs is limited or not indicated. Among the advantages of attachment-retained RPDs are the improvements in esthetics and biomechanics, as well as correction of the buccal arrangement of anterior teeth in Kennedy Class III partially edentulous arches. This article describes the treatment sequence and technique for the use of attachments in therapy combining FPD/RPD. © 2013 by the American College of Prosthodontists.

  15. Evaluation of FTA(®) card for the rescue of infectious foot-and-mouth disease virus by chemical transfection of extracted RNA in cultured cells.

    PubMed

    Biswal, Jitendra K; Subramaniam, Saravanan; Ranjan, Rajeev; Pattnaik, Bramhadev

    2016-08-01

    Foot-and-mouth disease (FMD) is a highly contagious epidemic disease of transboundary importance. Inadequate storage and shipment of suspected clinical samples can compromise the ability to detect and characterise FMD virus (FMDV) in endemic countries, thereby, leading to the loss of valuable virological and epidemiological data. This study, investigates the potential of using FTA(®) cards for dry transportation of clinical samples and subsequent recovery of infectious FMDV by chemical transfection of FTA(®) card fixed RNA as an alternative to the conventional cell culture based virus isolation method. A higher proportion of infectious FMDV was rescued from clinical samples (cell culture isolates, tongue epithelial suspension and impression smears) by the FTA(®) card fixed RNA transfection method (76%) compared to the conventional cell culture based virus isolation (56%), suggesting a better performance of the current RNA transfection procedure. Furthermore, it was possible to rescue live virus by the transfection of RNA extracted from FTA(®) card impregnated with clinical samples that had been stored at varying temperature (4-37 °C) up to a period of six weeks. The VP1 sequence data and antigenic relationships with the vaccine strains, between viruses rescued by FTA(®) card fixed RNA transfection and conventional cell culture, were comparable. Therefore, these results support the use of the FTA(®) card for the economic, dry, non-hazardous transport of FMD suspected clinical samples from the site of collection to national/international reference laboratories. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Clinical and radiographic comparison of the effects of two types of fixed retainers on periodontium - a randomized clinical trial.

    PubMed

    Torkan, Sepideh; Oshagh, Morteza; Khojastepour, Leila; Shahidi, Shoaleh; Heidari, Somayeh

    2014-08-27

    Most orthodontists believe that fixed retainers are necessary to maintain ideal dental relationships. However, untoward side effects might result from their long-term placement. The aim of this study was to evaluate the clinical and radiographic effect of two commonly used fixed retainers on the health of the periodontium. Thirty patients were randomly divided into two groups to receive either a fiber-reinforced composite retainer or a spiral wire retainer extended on the lingual surfaces of both maxillary and mandibular arches from canine to canine. Periapical radiographs were obtained from the patients at the time of placement of the retainers and after the 6-month period to assess the radiographic conditions of the periodontium. Clinical examination was carried out at the same two time intervals. Even though there were no significant differences between the two groups of study at the beginning of the trial, there were statistically significant differences after the 6-month follow-up regarding the main outcomes of the study. Nearly all indices showed to deteriorate after 6 months in the fiber-reinforced group, while in the spiral wire group, this was not the case. As for the secondary outcomes, radiographic examination did not reveal any statistically significant differences after 6 months or between the two groups. It can be concluded that spiral wire retainers elicit less detrimental periodontal response in the short-term follow-up compared to fiber-reinforced composite retainers as revealed by the primary outcomes of the study. ClinicalTrials.gov: NCT01314729.

  17. Do mobile clinics provide high-quality antenatal care? A comparison of care delivery, knowledge outcomes and perception of quality of care between fixed and mobile clinics in central Haiti.

    PubMed

    Phillips, Erica; Stoltzfus, Rebecca J; Michaud, Lesly; Pierre, Gracia Lionel Fils; Vermeylen, Francoise; Pelletier, David

    2017-10-16

    Antenatal care (ANC) is an important health service for women in developing countries, with numerous proven benefits. Global coverage of ANC has steadily increased over the past 30 years, in part due to increased community-based outreach. However, commensurate improvements in health outcomes such as reductions in the prevalence of maternal anemia and infants born small-for-gestational age have not been achieved, even with increased coverage, indicating that quality of care may be inadequate. Mobile clinics are one community-based strategy used to further improve coverage of ANC, but their quality of care delivery has rarely been evaluated. To determine the quality of care of ANC in central Haiti, we compared adherence to national guidelines between fixed and mobile clinics by performing direct observations of antenatal care consultations and exit interviews with recipients of care using a multi-stage random sampling procedure. Outcome variables were eight components of care, and women's knowledge and perception of care quality. There were significant differences in the predicted proportion or probability of recommended services for four of eight care components, including intake, laboratory examinations, infection control, and supplies, iron folic acid supplements and Tetanus Toxoid vaccine provided to women. These care components were more likely performed in fixed clinics, except for distribution of supplies, iron-folic acid supplements, and Tetanus Toxoid vaccine, more likely provided in mobile clinics. There were no differences between clinic type for the proportion of total physical exam procedures performed, health and communication messages delivered, provider communication or documentation. Women's knowledge about educational topics was poor, but women perceived extremely high quality of care in both clinic models. Although adherence to guidelines differed by clinic type for half of the care components, both clinics had a low percentage of overall services delivered. Efforts to improve provider performance and quality are therefore needed in both models. Mobile clinics must deliver high-quality ANC to improve health and nutrition outcomes.

  18. Returns to scientific publications for pharmaceutical products in the United States.

    PubMed

    Slejko, Julia F; Basu, Anirban; Sullivan, Sean D

    2018-02-01

    Drug-specific clinical and health economic and outcomes research (HEOR) publications have amassed, but their effect on drug sales is largely unknown. We estimated the impact of publications on pharmaceutical sales in 3 markets (statins, rheumatoid arthritis, and asthma drugs) with varying generic competition. An event-study approach with fixed effects and difference-in-fixed-effects modeling was used to estimate the causal effects of drug-specific publications on subsequent quarter's drug-specific sales and volume. High-impact clinical and HEOR publications have significant positive effects on sales (mediated through price) and volume in the statin market (high generic competition). High-impact clinical publications have a significant positive effect on sales (mediated through volume) in low-generic competition market (asthma). The effects of publications in the rheumatoid arthritis market (no generic competition) on sales were null. Manufacturers' investment in clinical and HEOR publications needs to be strategic and should be anticipated and complemented by public investments in such studies. Copyright © 2017 John Wiley & Sons, Ltd.

  19. 'Failure to fail' in nursing - A catch phrase or a real issue? A systematic integrative literature review.

    PubMed

    Hughes, Lynda J; Mitchell, Marion; Johnston, Amy N B

    2016-09-01

    'Failure to fail' is the allocation of pass grades to nursing students who do not display satisfactory clinical performance. This issue can have significant implications for individual students and assessors involved, as well as for nursing professionalism and patient safety. The aim of this systematic integrative literature review was to determine what is currently known about the issue of 'failure to fail' within undergraduate nursing programs. A literature search of five databases up to May 2015 was conducted to identify primary research papers. The search yielded 169 papers of which 24 met the inclusion criteria. The majority of papers had moderate or good methodological rigour, with most of the literature originating from the Northern Hemisphere. Five main themes emerged: failing a student is difficult; an emotional experience; confidence is required; unsafe student characteristics; and university support is required to fail students. The results suggest that 'failure to fail' is a real issue in tertiary facilities, with many complex facets. Given the costs of nurse education and the potential social and professional costs of poor quality nursing graduates, further rigorous research is required in this area. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Identifying demographic variables related to failed dental appointments in a university hospital-based residency program.

    PubMed

    Mathu-Muju, Kavita R; Li, Hsin-Fang; Hicks, James; Nash, David A; Kaplan, Alan; Bush, Heather M

    2014-01-01

    The objective of this study was to identify characteristics of pediatric patients who failed to keep the majority of their scheduled dental appointments in a pediatric dental clinic staffed by pediatric dental residents and faculty members. The electronic records of all patients appointed over a continuous 54 month period were analyzed. Appointment history and demographic variables were collected. The rate of failed appointments was calculated by dividing the number of failed appointments with the total number of appointments scheduled for the patient. There were 7,591 patients in the analyzable dataset scheduled with a total of 48,932 appointments. Factors associated with an increased rate of failed appointments included self-paying for dental care, having a resident versus a faculty member as the provider, rural residence, and adolescent aged patients. Multivariable regression models indicated self-paying patients had higher odds and rates of failed appointments than patients with Medicaid and private insurance. Access to care for children may be improved by increasing the availability of private and public insurance. The establishment of a dental home and its relationship to a child receiving continuous care in an institutional setting depends upon establishing a relationship with a specific dentist.

  1. Rocky Mountain spotted fever: a clinician's dilemma.

    PubMed

    Masters, Edwin J; Olson, Gary S; Weiner, Scott J; Paddock, Christopher D

    2003-04-14

    Rocky Mountain spotted fever is still the most lethal tick-vectored illness in the United States. We examine the dilemmas facing the clinician who is evaluating the patient with possible Rocky Mountain spotted fever, with particular attention to the following 8 pitfalls in diagnosis and treatment: (1) waiting for a petechial rash to develop before diagnosis; (2) misdiagnosing as gastroenteritis; (3) discounting a diagnosis when there is no history of a tick bite; (4) using an inappropriate geographic exclusion; (5) using an inappropriate seasonal exclusion; (6) failing to treat on clinical suspicion; (7) failing to elicit an appropriate history; and (8) failing to treat with doxycycline. Early diagnosis and proper treatment save lives.

  2. Kerosene-induced asthma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez de la Vega, A.; Casaco, A.; Garcia, M.

    1990-04-01

    Clinical evaluation of 286 asthmatic women showed 15.5% of those who improved clinically had contact with kerosene, while 43.9% of those who failed to improve used kerosene as fuel for cooking. In 16 women the onset of asthma occurred soon after they began to use kerosene. Kerosene can cause and aggravate asthma.

  3. A Children's Divorce Clinic: Analysis of 200 Cases in Hawaii.

    ERIC Educational Resources Information Center

    Waldron, Jane A.; And Others

    1986-01-01

    Analyzes data from children and families seen at the Children's Divorce Clinic. Finds that preschool children are often told nothing about the divorce and that ethnically mixed marriages tended to fail before nonmixed marriages. Reports data concerning custody and parents' emotional response to the divorce. (Author/ABB)

  4. "And I think that we can fix it": mental models used in high-risk surgical decision making.

    PubMed

    Kruser, Jacqueline M; Pecanac, Kristen E; Brasel, Karen J; Cooper, Zara; Steffens, Nicole M; McKneally, Martin F; Schwarze, Margaret L

    2015-04-01

    To examine how surgeons use the "fix-it" model to communicate with patients before high-risk operations. The "fix-it" model characterizes disease as an isolated abnormality that can be restored to normal form and function through medical intervention. This mental model is familiar to patients and physicians, but it is ineffective for chronic conditions and treatments that cannot achieve normalcy. Overuse may lead to permissive decision making favoring intervention. Efforts to improve surgical decision making will need to consider how mental models function in clinical practice, including "fix-it." We observed surgeons who routinely perform high-risk surgery during preoperative discussions with patients. We used qualitative content analysis to explore the use of "fix-it" in 48 audio-recorded conversations. Surgeons used the "fix-it" model for 2 separate purposes during preoperative conversations: (1) as an explanatory tool to facilitate patient understanding of disease and surgery, and (2) as a deliberation framework to assist in decision making. Although surgeons commonly used "fix-it" as an explanatory model, surgeons explicitly discussed limitations of the "fix-it" model as an independent rationale for operating as they deliberated about the value of surgery. Although the use of "fix-it" is familiar for explaining medical information to patients, surgeons recognize that the model can be problematic for determining the value of an operation. Whether patients can transition between understanding how their disease is fixed with surgery to a subsequent deliberation about whether they should have surgery is unclear and may have broader implications for surgical decision making.

  5. Lingual vs. labial fixed orthodontic appliances: systematic review and meta-analysis of treatment effects.

    PubMed

    Papageorgiou, Spyridon N; Gölz, Lina; Jäger, Andreas; Eliades, Theodore; Bourauel, Christoph

    2016-04-01

    The aim of this systematic review was to compare the therapeutic and adverse effects of lingual and labial orthodontic fixed appliances from clinical trials on human patients in an evidence-based manner. Randomized and prospective non-randomized clinical trials comparing lingual and labial appliances were included. Risk of bias within and across studies was assessed using the Cochrane tool and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Random-effects meta-analyses were conducted, followed by subgroup and sensitivity analyses. Six electronic databases were searched from inception to July 2015, without limitations. A total of 13 papers pertaining to 11 clinical trials were included with a total of 407 (34% male/66% female) patients. Compared with labial appliances, lingual appliances were associated with increased overall oral discomfort, increased speech impediment (measured using auditory analysis), worse speech performance assessed by laypersons, increased eating difficulty, and decreased intermolar width. On the other hand, lingual appliances were associated with increased intercanine width and significantly decreased anchorage loss of the maxillary first molar during space closure. Based on existing trials, there is insufficient evidence to make robust recommendations for lingual fixed orthodontic appliances regarding their therapeutic or adverse effects, as the quality of evidence was low. © 2016 Eur J Oral Sci.

  6. Preclinical safety and efficacy of a new recombinant FIX drug product for treatment of hemophilia B.

    PubMed

    Dietrich, Barbara; Schiviz, Alexandra; Hoellriegl, Werner; Horling, Frank; Benamara, Karima; Rottensteiner, Hanspeter; Turecek, Peter L; Schwarz, Hans Peter; Scheiflinger, Friedrich; Muchitsch, Eva-Maria

    2013-11-01

    Baxter has developed a new recombinant factor IX (rFIX) drug product (BAX326) for treating patients with hemophilia B, or congenital FIX deficiency. An extensive preclinical program evaluated the pharmacokinetics, efficacy, and safety of BAX326 in different species. The efficacy of BAX326 was tested in three mouse models of primary pharmacodynamics: tail-tip bleeding, carotid occlusion, and thrombelastography. The pharmacokinetics was evaluated after a single intravenous bolus injection in mice, rats, and macaques. Toxicity was assessed in rats and macaques, safety pharmacology in rabbits and macaques, and immunogenicity in mice. BAX326 was shown to be efficacious in all three primary pharmacodynamic studies (P ≤ 0.0076). Hemostatic efficacy was dose related and similar for the three lots tested. Pharmacokinetic results showed that rFIX activity and rFIX antigen concentrations declined in a bi-phasic manner, similar to a previously licensed rFIX product. BAX326 was well tolerated in rabbits and macaques at all dose levels; no thrombogenic events and no adverse clinical, respiratory, or cardiovascular effects occurred. BAX326 was also shown to have a similar immunogenicity profile to the comparator rFIX product in mice. These results demonstrate that BAX326 has a favorable preclinical safety and efficacy profile, predictive of a comparable effect to that of the previously licensed rFIX in humans.

  7. Use of a cost accounting system to evaluate costs of a VA special program.

    PubMed

    Menke, T J; Wray, N P

    1999-04-01

    The Department of Veterans Affairs (VA) established six mobile clinics to provide care for rural veterans. Each was operated by a parent VA Medical Center (VAMC). To describe the use of a cost-accounting system which does not provide costs at the service or patient level to determine the costs of the mobile clinics. Costs per visit were compared among the mobile clinics with the parent VAMCs and with simulated fixed-location clinics. Cost data came from VA's Centralized Accounting for Local Management (CALM) data. Utilization data came from VA's outpatient file. Information was obtained from the VAMCs' fiscal services to reallocate costs among the CALM subaccounts to generate cost data that was comparable among the mobile clinics. Costs per visit for the mobile clinics were twice as high as those of the parent VAMCs. Costs per visit would be lower at fixed-location clinics unless the volume were substantially less than that provided by the mobile clinics. Differences between cost allocations for accounting purposes and research are likely to necessitate adjusting cost accounting data for research purposes. Fortunately, information from the accountants or primary data can lead to a cost database which is appropriate for research evaluations. In the mobile clinics study, the analysis of cost accounting data led to the conclusion that mobile clinics were not a cost-effective way in which to provide care to rural veterans.

  8. Effect of first-encounter pretest on pass/fail rates of a clinical skills medical licensure examination.

    PubMed

    Roberts, William L; McKinley, Danette W; Boulet, John R

    2010-05-01

    Due to the high-stakes nature of medical exams it is prudent for test agencies to critically evaluate test data and control for potential threats to validity. For the typical multiple station performance assessments used in medicine, it may take time for examinees to become comfortable with the test format and administrative protocol. Since each examinee in the rotational sequence starts with a different task (e.g., simulated clinical encounter), those who are administered non-scored pretest material on their first station may have an advantage compared to those who are not. The purpose of this study is to investigate whether pass/fail rates are different across the sequence of pretest encounters administered during the testing day. First-time takers were grouped by the sequential order in which they were administered the pretest encounter. No statistically significant difference in fail rates was found between examinees who started with the pretest encounter and those who encountered the pretest encounter later in the sequence. Results indicate that current examination administration protocols do not present a threat to the validity of test score interpretations.

  9. [Medical expert consensus in AH on the clinical use of triple fixed-dose antihypertensive therapy in Spain].

    PubMed

    Mazón, P; Galve, E; Gómez, J; Gorostidi, M; Górriz, J L; Mediavilla, J D

    The opinion of experts (different specialties) on the triple fixed-dose antihypertensive therapy in clinical practice may differ. Online questionnaire with controversial aspects of the triple therapy answered by panel of experts in hypertension (HT) using two-round modified Delphi method. The questionnaire was completed by 158 experts: Internal Medicine (49), Nephrology (26), Cardiology (83). Consensus was reached (agreement) on 27/45 items (60%); 7 items showed differences statistically significant. Consensus was reached regarding: Predictive factors in the need for combination therapy and its efficacy vs. increasing the dose of a pretreatment, and advantage of triple therapy (prescription/adherence/cost/pressure control) vs. free combination. This consensus provides an overview of the clinical use of triple therapy in moderate-severe and resistant/difficult to control HT. Copyright © 2016 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Azilsartan medoxomil plus chlorthalidone reduces blood pressure more effectively than olmesartan plus hydrochlorothiazide in stage 2 systolic hypertension.

    PubMed

    Cushman, William C; Bakris, George L; White, William B; Weber, Michael A; Sica, Domenic; Roberts, Andrew; Lloyd, Eric; Kupfer, Stuart

    2012-08-01

    Azilsartan medoxomil, an effective, long-acting angiotensin II receptor blocker, is a new treatment for hypertension that is also being developed in fixed-dose combinations with chlorthalidone, a potent, long-acting thiazide-like diuretic. We compared once-daily fixed-dose combinations of azilsartan medoxomil/chlorthalidone force titrated to a high dose of either 40/25 mg or 80/25 mg with a fixed-dose combination of the angiotensin II receptor blocker olmesartan medoxomil plus the thiazide diuretic hydrochlorothiazide force titrated to 40/25 mg. The design was a randomized, 3-arm, double-blind, 12-week study of 1071 participants with baseline clinic systolic blood pressure 160 to 190 mm Hg and diastolic blood pressure ≤119 mm Hg. Patients had a mean age of 57 years; 59% were men, 73% were white, and 22% were black. At baseline, mean clinic blood pressure was 165/96 mm Hg and 24-hour mean blood pressure was 150/88 mm Hg. Changes in clinic (primary end point) and ambulatory systolic blood pressures at week 12 were significantly greater in both azilsartan medoxomil/chlorthalidone arms than in the olmesartan/hydrochlorothiazide arm (P<0.001). Changes in clinic systolic blood pressure (mean±SE) were -42.5±0.8, -44.0±0.8, and -37.1±0.8 mm Hg, respectively. Changes in 24-hour ambulatory systolic blood pressure were -33.9±0.8, -36.3±0.8, and -27.5±0.8 mm Hg, respectively. Adverse events leading to permanent drug discontinuation occurred in 7.9%, 14.5%, and 7.1% of the groups given azilsartan medoxomil/chlorthalidone 40/25 mg, azilsartan medoxomil/chlorthalidone 80/25 mg, and olmesartan/hydrochlorothiazide 40/25 mg, respectively. This large, forced-titration study has demonstrated superior antihypertensive efficacy of azilsartan medoxomil/chlorthalidone fixed-dose combinations compared with the maximum approved dose of olmesartan/hydrochlorothiazide.

  11. Effectiveness of Vildagliptin in Clinical Practice: Pooled Analysis of Three Korean Observational Studies (the VICTORY Study)

    PubMed Central

    Suh, Sunghwan; Song, Sun Ok; Kim, Jae Hyeon; Cho, Hyungjin

    2017-01-01

    The present observational study aimed to evaluate the clinical effectiveness of vildagliptin with metformin in Korean patients with type 2 diabetes mellitus (T2DM). Data were pooled from the vildagliptin postmarketing survey (PMS), the vildagliptin/metformin fixed drug combination (DC) PMS, and a retrospective observational study of vildagliptin/metformin (fixed DC or free DC). The effectiveness endpoint was the proportion of patients who achieved a glycemic target (HbA1c) of ≤7.0% at 24 weeks. In total, 4303 patients were included in the analysis; of these, 2087 patients were eligible. The mean patient age was 56.99 ± 11.25 years. Overall, 58.94% patients achieved an HbA1c target of ≤7.0% at 24 weeks. The glycemic target achievement rate was significantly greater in patients with baseline HbA1c < 7.5% versus ≥7.5% (84.64% versus 43.97%), receiving care at the hospital versus clinic (67.95% versus 52.33%), and receiving vildagliptin/metformin fixed DC versus free DC (70.69% versus 55.42%). Multivariate logistic regression analysis indicated that disease duration (P < 0.0001), baseline HbA1c (P < 0.0001), and DC type (P = 0.0103) had significant effects on drug effectiveness. Vildagliptin plus metformin appeared as an effective treatment option for patients with T2DM in clinical practice settings in Korea. PMID:29057274

  12. A randomized trial of 7-day doripenem versus 10-day imipenem-cilastatin for ventilator-associated pneumonia.

    PubMed

    Kollef, Marin H; Chastre, Jean; Clavel, Marc; Restrepo, Marcos I; Michiels, Bart; Kaniga, Koné; Cirillo, Iolanda; Kimko, Holly; Redman, Rebecca

    2012-11-13

    The aim of this study was to compare a 7-day course of doripenem to a 10-day course of imipenem-cilastatin for ventilator-associated pneumonia (VAP) due to Gram-negative bacteria. This was a prospective, double-blinded, randomized trial comparing a fixed 7-day course of doripenem one gram as a four-hour infusion every eight hours with a fixed 10-day course of imipenem-cilastatin one gram as a one-hour infusion every eight hours (April 2008 through June 2011). The study was stopped prematurely at the recommendation of the Independent Data Monitoring Committee that was blinded to treatment arm assignment and performed a scheduled review of data which showed signals that were close to the pre-specified stopping limits. The final analyses included 274 randomized patients. The clinical cure rate at the end of therapy (EOT) in the microbiological intent-to-treat (MITT) population was numerically lower for patients in the doripenem arm compared to the imipenem-cilastatin arm (45.6% versus 56.8%; 95% CI, -26.3% to 3.8%). Similarly, the clinical cure rate at EOT was numerically lower for patients with Pseudomonas aeruginosa VAP, the most common Gram-negative pathogen, in the doripenem arm compared to the imipenem-cilastatin arm (41.2% versus 60.0%; 95% CI, -57.2 to 19.5). All cause 28-day mortality in the MITT group was numerically greater for patients in the doripenem arm compared to the imipenem-cilastatin arm (21.5% versus 14.8%; 95% CI, -5.0 to 18.5) and for patients with P. aeruginosa VAP (35.3% versus 0.0%; 95% CI, 12.6 to 58.0). Among patients with microbiologically confirmed late-onset VAP, a fixed 7-day course of doripenem was found to have non-significant higher rates of clinical failure and mortality compared to a fixed 10-day course of imipenem-cilastatin. Consideration should be given to treating patients with VAP for more than seven days to optimize clinical outcome. ClinicalTrials.gov: NCT00589693.

  13. A randomized trial of 7-day doripenem versus 10-day imipenem-cilastatin for ventilator-associated pneumonia

    PubMed Central

    2012-01-01

    Introduction The aim of this study was to compare a 7-day course of doripenem to a 10-day course of imipenem-cilastatin for ventilator-associated pneumonia (VAP) due to Gram-negative bacteria. Methods This was a prospective, double-blinded, randomized trial comparing a fixed 7-day course of doripenem one gram as a four-hour infusion every eight hours with a fixed 10-day course of imipenem-cilastatin one gram as a one-hour infusion every eight hours (April 2008 through June 2011). Results The study was stopped prematurely at the recommendation of the Independent Data Monitoring Committee that was blinded to treatment arm assignment and performed a scheduled review of data which showed signals that were close to the pre-specified stopping limits. The final analyses included 274 randomized patients. The clinical cure rate at the end of therapy (EOT) in the microbiological intent-to-treat (MITT) population was numerically lower for patients in the doripenem arm compared to the imipenem-cilastatin arm (45.6% versus 56.8%; 95% CI, -26.3% to 3.8%). Similarly, the clinical cure rate at EOT was numerically lower for patients with Pseudomonas aeruginosa VAP, the most common Gram-negative pathogen, in the doripenem arm compared to the imipenem-cilastatin arm (41.2% versus 60.0%; 95% CI, -57.2 to 19.5). All cause 28-day mortality in the MITT group was numerically greater for patients in the doripenem arm compared to the imipenem-cilastatin arm (21.5% versus 14.8%; 95% CI, -5.0 to 18.5) and for patients with P. aeruginosa VAP (35.3% versus 0.0%; 95% CI, 12.6 to 58.0). Conclusions Among patients with microbiologically confirmed late-onset VAP, a fixed 7-day course of doripenem was found to have non-significant higher rates of clinical failure and mortality compared to a fixed 10-day course of imipenem-cilastatin. Consideration should be given to treating patients with VAP for more than seven days to optimize clinical outcome. Trial Registration ClinicalTrials.gov: NCT00589693 PMID:23148736

  14. Accounting for missing data in the estimation of contemporary genetic effective population size (N(e) ).

    PubMed

    Peel, D; Waples, R S; Macbeth, G M; Do, C; Ovenden, J R

    2013-03-01

    Theoretical models are often applied to population genetic data sets without fully considering the effect of missing data. Researchers can deal with missing data by removing individuals that have failed to yield genotypes and/or by removing loci that have failed to yield allelic determinations, but despite their best efforts, most data sets still contain some missing data. As a consequence, realized sample size differs among loci, and this poses a problem for unbiased methods that must explicitly account for random sampling error. One commonly used solution for the calculation of contemporary effective population size (N(e) ) is to calculate the effective sample size as an unweighted mean or harmonic mean across loci. This is not ideal because it fails to account for the fact that loci with different numbers of alleles have different information content. Here we consider this problem for genetic estimators of contemporary effective population size (N(e) ). To evaluate bias and precision of several statistical approaches for dealing with missing data, we simulated populations with known N(e) and various degrees of missing data. Across all scenarios, one method of correcting for missing data (fixed-inverse variance-weighted harmonic mean) consistently performed the best for both single-sample and two-sample (temporal) methods of estimating N(e) and outperformed some methods currently in widespread use. The approach adopted here may be a starting point to adjust other population genetics methods that include per-locus sample size components. © 2012 Blackwell Publishing Ltd.

  15. A systematic approach to the control of esthetic form.

    PubMed

    Preston, J D

    1976-04-01

    A systematic, orderly approach to the problem of establishing harmonious phonetics, esthetics, and function in fixed restorations has been described. The system requires an initial investment of time in performing an adequate diagnostic waxing, but recoups that time in many clinical and laboratory procedures. The method has proved a valuable asset in fixed prosthodontic care. The technique can be expanded and combined with other techniques with a little imagination and artistic bent.

  16. Nursing student clinical shift completion as a predictor of NCLEX failure.

    PubMed

    Woodworth, Julie A

    2014-01-01

    As competition for clinical sites increases, hospitals and nursing schools report the use of nontraditional student placements such as one 12-hour clinical shift; that was an option offered by the author's school. The author discusses implementation of 12-hour shifts and compared NCLEX fail rates of students on one 12-hour shift with students who had 2 weekly 6-hour shifts.

  17. Supplemental vibrational force does not reduce pain experience during initial alignment with fixed orthodontic appliances: a multicenter randomized clinical trial.

    PubMed

    Woodhouse, Neil R; DiBiase, Andrew T; Papageorgiou, Spyridon N; Johnson, Nicola; Slipper, Carmel; Grant, James; Alsaleh, Maryam; Cobourne, Martyn T

    2015-11-27

    This prospective randomized trial investigated the effect of supplemental vibrational force on orthodontic pain during alignment with fixed-appliances. Eighty-one subjects < 20 years-old undergoing extraction-based fixed-appliance treatment were randomly allocated to supplementary (20-minutes/day) use of an intra-oral vibrational device (AcceleDent(®)) (n = 29); an identical non-functional (sham) device (n = 25) or fixed-appliances only (n = 27). Each subject recorded pain intensity (using a 100-mm visual-analogue scale) and intake of oral analgesia in a questionnaire, following appliance-placement (T1) and first-adjustment (T2) for 1-week (immediately-after, 4, 24, 72-hours and at 1-week). Mean maximum-pain for the total sample was 72.96 mm [SD 21.59; 95%CI 68.19-77.74 mm] with no significant differences among groups (P = 0.282). Subjects taking analgesics reported slightly higher maximum-pain although this was not significant (P = 0.170). The effect of intervention was independent of analgesia (P = 0.883). At T1 and T2, a statistically and clinically significant increase in mean pain was seen at 4 and 24-hours, declining at 72-hours and becoming insignificant at 1-week. For mean alignment-rate, pain-intensity and use of analgesics, no significant differences existed between groups (P > 0.003). The only significant predictor for mean pain was time. Use of an AcceleDent vibrational device had no significant effect on orthodontic pain or analgesia consumption during initial alignment with fixed appliances.

  18. A comparative analysis between fixed bearing total knee arthroplasty (PFC Sigma) and rotating platform total knee arthroplasty (PFC-RP) with minimum 3-year follow-up.

    PubMed

    Jawed, Akram; Kumar, Vijay; Malhotra, R; Yadav, C S; Bhan, S

    2012-06-01

    Since the introduction of mobile bearing total knee designs nearly 30 years back, many studies have been done to evaluate its long-term result. Comparison with fixed bearing designs has been done in the past, but the studies were confounded by variables such as disease, surgeon, bone quality, pain tolerance, etc. We attempt to eliminate these variables in this study. A total of 50 patients who had bilateral arthritis of the knee with similar deformity and pre-operative range of motion on both sides agreed to have one knee replaced with mobile bearing total knee design (PFC-RP) and the other with a fixed bearing design (PFC Sigma) were prospectively evaluated. Comparative analysis of both the designs was done at a mean follow-up of 40 months, minimizing patient, surgeon and observer related bias. Clinical and radiographic outcome, survival and complication rates were compared. At a mean follow-up of 40 months (range 36-47 months), no benefit of mobile bearing (PFC-RP) over fixed bearing design (PFC Sigma) could be demonstrated with respect to Knee Society scores, pain scores, range of flexion, subject preference or patello-femoral complication rates. Radiographs showed no difference in prosthetic alignment. No patient required a revision surgery till last follow-up. Our study demonstrated no advantage of the mobile-bearing arthroplasty over fixed bearing arthroplasty with regard to clinical results at short-term follow-up. However, longer follow-up is necessary to confirm whether these results are sustained.

  19. Do fixed-dose combination pills or unit-of-use packaging improve adherence? A systematic review.

    PubMed Central

    Connor, Jennie; Rafter, Natasha; Rodgers, Anthony

    2004-01-01

    Adequate adherence to medication regimens is central to the successful treatment of communicable and noncommunicable disease. Fixed-dose combination pills and unit-of-use packaging are therapy-related interventions that are designed to simplify medication regimens and so potentially improve adherence. We conducted a systematic review of relevant randomized trials in order to quantify the effects of fixed-dose combination pills and unit-of-use packaging, compared with medications as usually presented, in terms of adherence to treatment and improved outcomes. Only 15 trials met the inclusion criteria; fixed-dose combination pills were investigated in three of these, while unit-of-use packaging was studied in 12 trials. The trials involved treatments for communicable diseases (n = 5), blood pressure lowering medications (n = 3), diabetic patients (n = 1), vitamin supplementation (n = 1) and management of multiple medications by the elderly (n = 5). The results of the trials suggested that there were trends towards improved adherence and/or clinical outcomes in all but three of the trials; this reached statistical significance in four out of seven trials reporting a clinically relevant or intermediate end-point, and in seven out of thirteen trials reporting medication adherence. Measures of outcome were, however, heterogeneous, and interpretation was further limited by methodological issues, particularly small sample size, short duration and loss to follow-up. Overall, the evidence suggests that fixed-dose combination pills and unit-of-use packaging are likely to improve adherence in a range of settings, but the limitations of the available evidence means that uncertainty remains about the size of these benefits. PMID:15654408

  20. Intraoperative Imaging Guidance for Sentinel Node Biopsy in Melanoma Using a Mobile Gamma Camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dengel, Lynn T; Judy, Patricia G; Petroni, Gina R

    2011-04-01

    The objective is to evaluate the sensitivity and clinical utility of intraoperative mobile gamma camera (MGC) imaging in sentinel lymph node biopsy (SLNB) in melanoma. The false-negative rate for SLNB for melanoma is approximately 17%, for which failure to identify the sentinel lymph node (SLN) is a major cause. Intraoperative imaging may aid in detection of SLN near the primary site, in ambiguous locations, and after excision of each SLN. The present pilot study reports outcomes with a prototype MGC designed for rapid intraoperative image acquisition. We hypothesized that intraoperative use of the MGC would be feasible and that sensitivitymore » would be at least 90%. From April to September 2008, 20 patients underwent Tc99 sulfur colloid lymphoscintigraphy, and SLNB was performed with use of a conventional fixed gamma camera (FGC), and gamma probe followed by intraoperative MGC imaging. Sensitivity was calculated for each detection method. Intraoperative logistical challenges were scored. Cases in which MGC provided clinical benefit were recorded. Sensitivity for detecting SLN basins was 97% for the FGC and 90% for the MGC. A total of 46 SLN were identified: 32 (70%) were identified as distinct hot spots by preoperative FGC imaging, 31 (67%) by preoperative MGC imaging, and 43 (93%) by MGC imaging pre- or intraoperatively. The gamma probe identified 44 (96%) independent of MGC imaging. The MGC provided defined clinical benefit as an addition to standard practice in 5 (25%) of 20 patients. Mean score for MGC logistic feasibility was 2 on a scale of 1-9 (1 = best). Intraoperative MGC imaging provides additional information when standard techniques fail or are ambiguous. Sensitivity is 90% and can be increased. This pilot study has identified ways to improve the usefulness of an MGC for intraoperative imaging, which holds promise for reducing false negatives of SLNB for melanoma.« less

  1. Procedure-specific assessment tool for flexible pharyngo-laryngoscopy: gathering validity evidence and setting pass-fail standards.

    PubMed

    Melchiors, Jacob; Petersen, K; Todsen, T; Bohr, A; Konge, Lars; von Buchwald, Christian

    2018-06-01

    The attainment of specific identifiable competencies is the primary measure of progress in the modern medical education system. The system, therefore, requires a method for accurately assessing competence to be feasible. Evidence of validity needs to be gathered before an assessment tool can be implemented in the training and assessment of physicians. This evidence of validity must according to the contemporary theory on validity be gathered from specific sources in a structured and rigorous manner. The flexible pharyngo-laryngoscopy (FPL) is central to the otorhinolaryngologist. We aim to evaluate the flexible pharyngo-laryngoscopy assessment tool (FLEXPAT) created in a previous study and to establish a pass-fail level for proficiency. Eighteen physicians with different levels of experience (novices, intermediates, and experienced) were recruited to the study. Each performed an FPL on two patients. These procedures were video recorded, blinded, and assessed by two specialists. The score was expressed as the percentage of a possible max score. Cronbach's α was used to analyze internal consistency of the data, and a generalizability analysis was performed. The scores of the three different groups were explored, and a pass-fail level was determined using the contrasting groups' standard setting method. Internal consistency was strong with a Cronbach's α of 0.86. We found a generalizability coefficient of 0.72 sufficient for moderate stakes assessment. We found a significant difference between the novice and experienced groups (p < 0.001) and strong correlation between experience and score (Pearson's r = 0.75). The pass/fail level was established at 72% of the maximum score. Applying this pass-fail level in the test population resulted in half of the intermediary group receiving a failing score. We gathered validity evidence for the FLEXPAT according to the contemporary framework as described by Messick. Our results support a claim of validity and are comparable to other studies exploring clinical assessment tools. The high rate of physicians underperforming in the intermediary group demonstrates the need for continued educational intervention. Based on our work, we recommend the use of the FLEXPAT in clinical assessment of FPL and the application of a pass-fail level of 72% for proficiency.

  2. Task-Specific and Functional Effects of Speed-Focused Elliptical or Motor-Assisted Cycle Training in Children With Bilateral Cerebral Palsy: Randomized Clinical Trial.

    PubMed

    Damiano, Diane L; Stanley, Christopher J; Ohlrich, Laurie; Alter, Katharine E

    2017-08-01

    Locomotor training using treadmills or robotic devices is commonly utilized to improve gait in cerebral palsy (CP); however, effects are inconsistent and fail to exceed those of equally intense alternatives. Possible limitations of existing devices include fixed nonvariable rhythm and too much limb or body weight assistance. To quantify and compare effectiveness of a motor-assisted cycle and a novel alternative, an elliptical, in CP to improve interlimb reciprocal coordination through intensive speed-focused leg training. A total of 27 children with bilateral CP, 5 to 17 years old, were randomized to 12 weeks of 20 minutes, 5 days per week home-based training (elliptical = 14; cycle = 13) at a minimum of 40 revolutions per minute, with resistance added when speed target was achieved. Primary outcomes were self-selected and fastest voluntary cadence on the devices and gait speed. Secondary outcomes included knee muscle strength, and selective control and functional mobility measures. Cadence on trained but not nontrained devices increased, demonstrating task specificity of training and increased exercise capability. Mean gait speed did not increase in either group, nor did parent-reported functional mobility. Knee extensor strength increased in both. An interaction between group and time was seen in selective control with scores slightly increasing for the elliptical and decreasing for the cycle, possibly related to tighter limb coupling with cycling. Task-specific effects were similarly positive across groups, but no transfer was seen to gait or function. Training dose was low (≤20 hours) compared with intensive upper-limb training recommendations and may be insufficient to produce appreciable clinical change.

  3. A double-blind, placebo-controlled, randomized trial of the effects of dark chocolate and cocoa on variables associated with neuropsychological functioning and cardiovascular health: clinical findings from a sample of healthy, cognitively intact older adults.

    PubMed

    Crews, W David; Harrison, David W; Wright, James W

    2008-04-01

    In recent years, there has been increased interest in the potential health-related benefits of antioxidant- and phytochemical-rich dark chocolate and cocoa. The objective of the study was to examine the short-term (6 wk) effects of dark chocolate and cocoa on variables associated with neuropsychological functioning and cardiovascular health in healthy older adults. A double-blind, placebo-controlled, fixed-dose, parallel-group clinical trial was used. Participants (n = 101) were randomly assigned to receive a 37-g dark chocolate bar and 8 ounces (237 mL) of an artificially sweetened cocoa beverage or similar placebo products each day for 6 wk. No significant group (dark chocolate and cocoa or placebo)-by-trial (baseline, midpoint, and end-of-treatment assessments) interactions were found for the neuropsychological, hematological, or blood pressure variables examined. In contrast, the midpoint and end-of-treatment mean pulse rate assessments in the dark chocolate and cocoa group were significantly higher than those at baseline and significantly higher than the midpoint and end-of-treatment rates in the control group. Results of a follow-up questionnaire item on the treatment products that participants believed they had consumed during the trial showed that more than half of the participants in both groups correctly identified the products that they had ingested during the experiment. This investigation failed to support the predicted beneficial effects of short-term dark chocolate and cocoa consumption on any of the neuropsychological or cardiovascular health-related variables included in this research. Consumption of dark chocolate and cocoa was, however, associated with significantly higher pulse rates at 3- and 6-wk treatment assessments.

  4. Prefabricated Bar System for Immediate Loading in Edentulous Patients: A 5-Year Follow-Up Prospective Longitudinal Study

    PubMed Central

    Gherlone, Enrico F.; Rapanelli, Andrea; Crespi, Roberto; Gastaldi, Giorgio

    2018-01-01

    Objectives The aim of this clinical study was to evaluate a new type of prefabricated bar system, supported by axial and tilted implants at 5-year follow-up. Materials and Methods Twenty-nine consecutive participants (19 females, 10 males) (mean age 61.4 years), edentulous in one or both jaws, with severe atrophy of the posterior regions, were treated according to the All-on-four® protocol with immediately loaded axial (64) and tilted (64) implants supporting complete-arch screw-retained prostheses (12 maxillary, 20 mandibular) featuring a prefabricated bar as framework. Follow-up visits were performed at 3, 6, 12, 24, 48, and 60 months after implant insertion. Radiographic assessments were made using panoramic radiographs obtained immediately after surgery and at each follow-up visit. Bone level measurements around the axial and tilted implants were compared by means of the Student's t-test. Results One axial implant failed in the lower jaw and did not compromise prosthetic function. The 60-month overall implant survival rate was 100% for axially positioned implants and 98.44% for tilted implants. The implant survival rates were 100% in the maxilla and 98.75% in the mandible. None of the 32 fixed prostheses were lost during the observation period, representing a prosthetic survival rate of 100%. No statistically significant differences (P > 0.05) in marginal bone loss between tilted and axial implants were detected in either jaw over time. Conclusions The use of the evaluated prefabricated bar for immediately loaded implants placed according to the All-on-four concept may significantly reduce implant failures; however, more long-term prospective clinical trials are needed to affirm the effectiveness of the surgical-prosthetic protocol. PMID:29682552

  5. A minipig model of maxillary distraction osteogenesis.

    PubMed

    Papadaki, Maria E; Troulis, Maria J; Glowacki, Julie; Kaban, Leonard B

    2010-11-01

    To establish a porcine model for maxillary distraction osteogenesis and to document the sequence of bone formation in the zone of advancement. Female Yucatan minipigs (n = 9) in the mixed dentition stage underwent modified Le Fort I osteotomy through a vestibular incision under general anesthesia. A unidirectional, semiburied Le Fort I distraction device was fixed across the osteotomy. The distraction protocol was 0-day latency, 1-mm/d rate for 12 days, and 24 days of fixation. Maxillary specimens (n = 9) were harvested and divided in half at the end of distraction (n = 6 sides), midfixation (n = 6), and the end of fixation (n = 6). Clinical stability, volume, and radiographic density across the zone of advancement were graded on semiquantitative scales. Specimens were stained with hematoxylin and eosin and examined with light microscopy. Animals tolerated the operation, the distraction and fixation periods. There were no infections and no devices failed. At the end of the distraction period, bone trabeculae were present at the periphery and fibrous tissues, and vessels, preosteoblasts, and osteoblasts were present in the center of the zone of advancement. Islands of chondrocyte-like cells appeared in 1 specimen each at midfixation and the end of fixation. At the end of fixation, clinical stability and radiographic density were graded 3/3 and bone formation was complete across the advancement zone in all specimens. A model for Le Fort I distraction osteogenesis was established. Intramembranous bone formation was the predominant mechanism of healing in the zone of advancement. Latency was not necessary for bone formation in this minipig model. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. CDO1 promoter methylation is associated with gene silencing and is a prognostic biomarker for biochemical recurrence-free survival in prostate cancer patients.

    PubMed

    Meller, Sebastian; Zipfel, Lisa; Gevensleben, Heidrun; Dietrich, Jörn; Ellinger, Jörg; Majores, Michael; Stein, Johannes; Sailer, Verena; Jung, Maria; Kristiansen, Glen; Dietrich, Dimo

    2016-12-01

    Molecular biomarkers may facilitate the distinction between aggressive and clinically insignificant prostate cancer (PCa), thereby potentially aiding individualized treatment. We analyzed cysteine dioxygenase 1 (CDO1) promoter methylation and mRNA expression in order to evaluate its potential as prognostic biomarker. CDO1 methylation and mRNA expression were determined in cell lines and formalin-fixed paraffin-embedded prostatectomy specimens from a first cohort of 300 PCa patients using methylation-specific qPCR and qRT-PCR. Univariate and multivariate Cox proportional hazards and Kaplan-Meier analyses were performed to evaluate biochemical recurrence (BCR)-free survival. Results were confirmed in an independent second cohort comprising 498 PCa cases. Methylation and mRNA expression data from the second cohort were generated by The Cancer Genome Atlas (TCGA) Research Network by means of Infinium HumanMethylation450 BeadChip and RNASeq. CDO1 was hypermethylated in PCa compared to normal adjacent tissues and benign prostatic hyperplasia (P < 0.001) and was associated with reduced gene expression (ρ = -0.91, P = 0.005). Using two different methodologies for methylation quantification, high CDO1 methylation as continuous variable was associated with BCR in univariate analysis (first cohort: HR = 1.02, P = 0.002, 95% CI [1.01-1.03]; second cohort: HR = 1.02, P = 0.032, 95% CI [1.00-1.03]) but failed to reach statistical significance in multivariate analysis. CDO1 promoter methylation is involved in gene regulation and is a potential prognostic biomarker for BCR-free survival in PCa patients following radical prostatectomy. Further studies are needed to validate CDO1 methylation assays and to evaluate the clinical utility of CDO1 methylation for the management of PCa.

  7. Nonlinear isochrones in murine left ventricular pressure-volume loops: how well does the time-varying elastance concept hold?

    PubMed

    Claessens, T E; Georgakopoulos, D; Afanasyeva, M; Vermeersch, S J; Millar, H D; Stergiopulos, N; Westerhof, N; Verdonck, P R; Segers, P

    2006-04-01

    The linear time-varying elastance theory is frequently used to describe the change in ventricular stiffness during the cardiac cycle. The concept assumes that all isochrones (i.e., curves that connect pressure-volume data occurring at the same time) are linear and have a common volume intercept. Of specific interest is the steepest isochrone, the end-systolic pressure-volume relationship (ESPVR), of which the slope serves as an index for cardiac contractile function. Pressure-volume measurements, achieved with a combined pressure-conductance catheter in the left ventricle of 13 open-chest anesthetized mice, showed a marked curvilinearity of the isochrones. We therefore analyzed the shape of the isochrones by using six regression algorithms (two linear, two quadratic, and two logarithmic, each with a fixed or time-varying intercept) and discussed the consequences for the elastance concept. Our main observations were 1) the volume intercept varies considerably with time; 2) isochrones are equally well described by using quadratic or logarithmic regression; 3) linear regression with a fixed intercept shows poor correlation (R(2) < 0.75) during isovolumic relaxation and early filling; and 4) logarithmic regression is superior in estimating the fixed volume intercept of the ESPVR. In conclusion, the linear time-varying elastance fails to provide a sufficiently robust model to account for changes in pressure and volume during the cardiac cycle in the mouse ventricle. A new framework accounting for the nonlinear shape of the isochrones needs to be developed.

  8. Organized chaos: scatter in the relation between stellar mass and halo mass in small galaxies

    NASA Astrophysics Data System (ADS)

    Garrison-Kimmel, Shea; Bullock, James S.; Boylan-Kolchin, Michael; Bardwell, Emma

    2017-01-01

    We use Local Group galaxy counts together with the ELVIS N-body simulations to explore the relationship between the scatter and slope in the stellar mass versus halo mass relation at low masses, M⋆ ≃ 105-108 M⊙. Assuming models with lognormal scatter about a median relation of the form M_star ∝ M_halo^α, the preferred log-slope steepens from α ≃ 1.8 in the limit of zero scatter to α ≃ 2.6 in the case of 2 dex of scatter in M⋆ at fixed halo mass. We provide fitting functions for the best-fitting relations as a function of scatter, including cases where the relation becomes increasingly stochastic with decreasing mass. We show that if the scatter at fixed halo mass is large enough (≳ 1 dex) and if the median relation is steep enough (α ≳ 2), then the `too-big-to-fail' problem seen in the Local Group can be self-consistently eliminated in about ˜5-10 per cent of realizations. This scenario requires that the most massive subhaloes host unobservable ultra-faint dwarfs fairly often; we discuss potentially observable signatures of these systems. Finally, we compare our derived constraints to recent high-resolution simulations of dwarf galaxy formation in the literature. Though simulation-to-simulation scatter in M⋆ at fixed Mhalo is large among different authors (˜2 dex), individual codes produce relations with much less scatter and usually give relations that would overproduce local galaxy counts.

  9. Dose Rationalization of Pembrolizumab and Nivolumab Using Pharmacokinetic Modeling and Simulation and Cost Analysis.

    PubMed

    Ogungbenro, Kayode; Patel, Alkesh; Duncombe, Robert; Nuttall, Richard; Clark, James; Lorigan, Paul

    2018-04-01

    Pembrolizumab and nivolumab are highly selective anti-programmed cell death 1 (PD-1) antibodies approved for the treatment of advanced malignancies. Variable exposure and significant wastage have been associated with body size dosing of monoclonal antibodies (mAbs). The following dosing strategies were evaluated using simulations: body weight, dose banding, fixed dose, and pharmacokinetic (PK)-based methods. The relative cost to body weight dosing for band, fixed 150 mg and 200 mg, and PK-derived strategies were -15%, -25%, + 7%, and -16% for pembrolizumab and -8%, -6%, and -10% for band, fixed, and PK-derived strategies for nivolumab, respectively. Relative to mg/kg doses, the median exposures were -1.0%, -4.6%, + 27.1%, and +3.0% for band, fixed 150 mg, fixed 200 mg, and PK-derived strategies, respectively, for pembrolizumab and -3.1%, + 1.9%, and +1.4% for band, fixed 240 mg, and PK-derived strategies, respectively, for nivolumab. Significant wastage can be reduced by alternative dosing strategies without compromising exposure and efficacy. © 2017 American Society for Clinical Pharmacology and Therapeutics.

  10. Time Series Analysis for Forecasting Hospital Census: Application to the Neonatal Intensive Care Unit

    PubMed Central

    Hoover, Stephen; Jackson, Eric V.; Paul, David; Locke, Robert

    2016-01-01

    Summary Background Accurate prediction of future patient census in hospital units is essential for patient safety, health outcomes, and resource planning. Forecasting census in the Neonatal Intensive Care Unit (NICU) is particularly challenging due to limited ability to control the census and clinical trajectories. The fixed average census approach, using average census from previous year, is a forecasting alternative used in clinical practice, but has limitations due to census variations. Objective Our objectives are to: (i) analyze the daily NICU census at a single health care facility and develop census forecasting models, (ii) explore models with and without patient data characteristics obtained at the time of admission, and (iii) evaluate accuracy of the models compared with the fixed average census approach. Methods We used five years of retrospective daily NICU census data for model development (January 2008 – December 2012, N=1827 observations) and one year of data for validation (January – December 2013, N=365 observations). Best-fitting models of ARIMA and linear regression were applied to various 7-day prediction periods and compared using error statistics. Results The census showed a slightly increasing linear trend. Best fitting models included a non-seasonal model, ARIMA(1,0,0), seasonal ARIMA models, ARIMA(1,0,0)x(1,1,2)7 and ARIMA(2,1,4)x(1,1,2)14, as well as a seasonal linear regression model. Proposed forecasting models resulted on average in 36.49% improvement in forecasting accuracy compared with the fixed average census approach. Conclusions Time series models provide higher prediction accuracy under different census conditions compared with the fixed average census approach. Presented methodology is easily applicable in clinical practice, can be generalized to other care settings, support short- and long-term census forecasting, and inform staff resource planning. PMID:27437040

  11. Time Series Analysis for Forecasting Hospital Census: Application to the Neonatal Intensive Care Unit.

    PubMed

    Capan, Muge; Hoover, Stephen; Jackson, Eric V; Paul, David; Locke, Robert

    2016-01-01

    Accurate prediction of future patient census in hospital units is essential for patient safety, health outcomes, and resource planning. Forecasting census in the Neonatal Intensive Care Unit (NICU) is particularly challenging due to limited ability to control the census and clinical trajectories. The fixed average census approach, using average census from previous year, is a forecasting alternative used in clinical practice, but has limitations due to census variations. Our objectives are to: (i) analyze the daily NICU census at a single health care facility and develop census forecasting models, (ii) explore models with and without patient data characteristics obtained at the time of admission, and (iii) evaluate accuracy of the models compared with the fixed average census approach. We used five years of retrospective daily NICU census data for model development (January 2008 - December 2012, N=1827 observations) and one year of data for validation (January - December 2013, N=365 observations). Best-fitting models of ARIMA and linear regression were applied to various 7-day prediction periods and compared using error statistics. The census showed a slightly increasing linear trend. Best fitting models included a non-seasonal model, ARIMA(1,0,0), seasonal ARIMA models, ARIMA(1,0,0)x(1,1,2)7 and ARIMA(2,1,4)x(1,1,2)14, as well as a seasonal linear regression model. Proposed forecasting models resulted on average in 36.49% improvement in forecasting accuracy compared with the fixed average census approach. Time series models provide higher prediction accuracy under different census conditions compared with the fixed average census approach. Presented methodology is easily applicable in clinical practice, can be generalized to other care settings, support short- and long-term census forecasting, and inform staff resource planning.

  12. [Canine teeth as an experimental model for fixed stomatologic prosthesis].

    PubMed

    Redzepagić, S

    1996-01-01

    Clinical researches, especially pathological-histological experimental researches in mouth of patient reach the level of impossible, from the ethical and law aspect. Trying to define particular state concerning relation of fixed protetical work in the mouth of patient to tooth caries and surrounding belonging tissues, there is a question whether it is necessary to establish milieu-in vivo--which follows scientifically established principles. These principles are necessary for converting results which would become valid in scientific defining of state in the mouth of patient, as well as on the tissues which we want to research clinically and experimentally. Experimental animals are the second choice for researching tissues of human beings. Dogs have many conveniences that classify them into most usually experimental animal.

  13. High Speed Jet Noise Prediction Using Large Eddy Simulation

    NASA Technical Reports Server (NTRS)

    Lele, Sanjiva K.

    2002-01-01

    Current methods for predicting the noise of high speed jets are largely empirical. These empirical methods are based on the jet noise data gathered by varying primarily the jet flow speed, and jet temperature for a fixed nozzle geometry. Efforts have been made to correlate the noise data of co-annular (multi-stream) jets and for the changes associated with the forward flight within these empirical correlations. But ultimately these emipirical methods fail to provide suitable guidance in the selection of new, low-noise nozzle designs. This motivates the development of a new class of prediction methods which are based on computational simulations, in an attempt to remove the empiricism of the present day noise predictions.

  14. Isolated rotor noise due to inlet distortion or turbulence

    NASA Technical Reports Server (NTRS)

    Mani, R.

    1974-01-01

    Theoretical formulation, analysis, and results are presented that are necessary to analyze quadrupole noise generated from a loaded, subsonic rotor because of its interaction with an inflow distortion or inlet turbulence. The ratio of quadrupole to dipole noise is largely a function of the axial Mach number, wheel tip Mach number, rotor solidity, and total pressure ratio across the rotor. It is relatively independent of the specific form of the inflow distortion or inlet turbulence. Comparisons with experimental data only succeed in predicting gross levels at a given speed and fail to predict the variation of noise at fixed speed with flow and pressure ratio. Likely sources of this discrepancy are discussed.

  15. Efficacy of the chelating agent CaEDTA in reversing lead-induced changes in behavior.

    PubMed

    Cory-Slechta, D A; Weiss, B

    1989-01-01

    The chelating agent CaEDTA has been reported to reverse the deficits in intellectual function and performance associated with Pb (lead) exposure in children. However, such studies have not included rigorous controls for the intervention procedures per se. The experiments reported here examined reversibility of performance changes in a rat model based on behavior sensitive to low-level Pb exposure. Rats were exposed to 50 ppm sodium or Pb acetate in drinking water from weaning. Performance maintained under a Fixed-Interval schedule of food reinforcement began at 55 days of age. Following the onset of the characteristic increase in short interresponse times (IRTs) associated with low-level Pb exposure after 35 experimental sessions, Pb treatment was terminated. Animals within both the control and Pb groups were then matched on the basis of performance indices and injected daily for 5 days with either saline, 75 mg/kg or 150 mg/kg CaEDTA. Subsequent changes in F1 performance were monitored for 35-60 sessions. No consistent effects of CaEDTA were detected in control animals. CaEDTA treatment failed to reverse the behavioral effects in Pb-exposed animals. If anything, it tended to further increase the proportion of short IRTs. These data suggest that better controlled clinical studies are warranted to evaluate the efficacy of CaEDTA in reversing Pb-induced behavioral effects before its application for these purposes becomes widespread.

  16. Patient-specific models of cardiac biomechanics

    NASA Astrophysics Data System (ADS)

    Krishnamurthy, Adarsh; Villongco, Christopher T.; Chuang, Joyce; Frank, Lawrence R.; Nigam, Vishal; Belezzuoli, Ernest; Stark, Paul; Krummen, David E.; Narayan, Sanjiv; Omens, Jeffrey H.; McCulloch, Andrew D.; Kerckhoffs, Roy C. P.

    2013-07-01

    Patient-specific models of cardiac function have the potential to improve diagnosis and management of heart disease by integrating medical images with heterogeneous clinical measurements subject to constraints imposed by physical first principles and prior experimental knowledge. We describe new methods for creating three-dimensional patient-specific models of ventricular biomechanics in the failing heart. Three-dimensional bi-ventricular geometry is segmented from cardiac CT images at end-diastole from patients with heart failure. Human myofiber and sheet architecture is modeled using eigenvectors computed from diffusion tensor MR images from an isolated, fixed human organ-donor heart and transformed to the patient-specific geometric model using large deformation diffeomorphic mapping. Semi-automated methods were developed for optimizing the passive material properties while simultaneously computing the unloaded reference geometry of the ventricles for stress analysis. Material properties of active cardiac muscle contraction were optimized to match ventricular pressures measured by cardiac catheterization, and parameters of a lumped-parameter closed-loop model of the circulation were estimated with a circulatory adaptation algorithm making use of information derived from echocardiography. These components were then integrated to create a multi-scale model of the patient-specific heart. These methods were tested in five heart failure patients from the San Diego Veteran's Affairs Medical Center who gave informed consent. The simulation results showed good agreement with measured echocardiographic and global functional parameters such as ejection fraction and peak cavity pressures.

  17. Revision Arthroscopic Repair Versus Latarjet Procedure in Patients With Recurrent Instability After Initial Repair Attempt: A Cost-Effectiveness Model.

    PubMed

    Makhni, Eric C; Lamba, Nayan; Swart, Eric; Steinhaus, Michael E; Ahmad, Christopher S; Romeo, Anthony A; Verma, Nikhil N

    2016-09-01

    To compare the cost-effectiveness of arthroscopic revision instability repair and Latarjet procedure in treating patients with recurrent instability after initial arthroscopic instability repair. An expected-value decision analysis of revision arthroscopic instability repair compared with Latarjet procedure for recurrent instability followed by failed repair attempt was modeled. Inputs regarding procedure cost, clinical outcomes, and health utilities were derived from the literature. Compared with revision arthroscopic repair, Latarjet was less expensive ($13,672 v $15,287) with improved clinical outcomes (43.78 v 36.76 quality-adjusted life-years). Both arthroscopic repair and Latarjet were cost-effective compared with nonoperative treatment (incremental cost-effectiveness ratios of 3,082 and 1,141, respectively). Results from sensitivity analyses indicate that under scenarios of high rates of stability postoperatively, along with improved clinical outcome scores, revision arthroscopic repair becomes increasingly cost-effective. Latarjet procedure for failed instability repair is a cost-effective treatment option, with lower costs and improved clinical outcomes compared with revision arthroscopic instability repair. However, surgeons must still incorporate clinical judgment into treatment algorithm formation. Level IV, expected value decision analysis. Copyright © 2016. Published by Elsevier Inc.

  18. Creating Lasting Behavioral Change through the Generalization Analysis Worksheet

    ERIC Educational Resources Information Center

    Brady, John; Kotkin, Ron

    2011-01-01

    The goal of any behavioral program is to facilitate lasting change. A significant criticism of behavioral programs is that they work in the clinical setting but do not generalize once the clinical program is stopped. The authors suggest that behavioral programs often do not generalize because clinicians fail to plan for generalization to occur…

  19. Meta-analysis in evidence-based healthcare: a paradigm shift away from random effects is overdue.

    PubMed

    Doi, Suhail A R; Furuya-Kanamori, Luis; Thalib, Lukman; Barendregt, Jan J

    2017-12-01

    Each year up to 20 000 systematic reviews and meta-analyses are published whose results influence healthcare decisions, thus making the robustness and reliability of meta-analytic methods one of the world's top clinical and public health priorities. The evidence synthesis makes use of either fixed-effect or random-effects statistical methods. The fixed-effect method has largely been replaced by the random-effects method as heterogeneity of study effects led to poor error estimation. However, despite the widespread use and acceptance of the random-effects method to correct this, it too remains unsatisfactory and continues to suffer from defective error estimation, posing a serious threat to decision-making in evidence-based clinical and public health practice. We discuss here the problem with the random-effects approach and demonstrate that there exist better estimators under the fixed-effect model framework that can achieve optimal error estimation. We argue for an urgent return to the earlier framework with updates that address these problems and conclude that doing so can markedly improve the reliability of meta-analytical findings and thus decision-making in healthcare.

  20. Relationship of pass/fail grading and curriculum structure with well-being among preclinical medical students: a multi-institutional study.

    PubMed

    Reed, Darcy A; Shanafelt, Tait D; Satele, Daniel W; Power, David V; Eacker, Anne; Harper, William; Moutier, Christine; Durning, Steven; Massie, F Stanford; Thomas, Matthew R; Sloan, Jeff A; Dyrbye, Liselotte N

    2011-11-01

    Psychological distress is common among medical students. Curriculum structure and grading scales are modifiable learning environment factors that may influence student well-being. The authors sought to examine relationships among curriculum structures, grading scales, and student well-being. The authors surveyed 2,056 first- and second-year medical students at seven U.S. medical schools in 2007. They used the Perceived Stress Scale, Maslach Burnout Inventory, and Medical Outcomes Study Short Form (SF-8) to measure stress, burnout, and quality of life, respectively. They measured curriculum structure using hours spent in didactic, clinical, and testing experiences. Grading scales were categorized as two categories (pass/fail) versus three or more categories (e.g., honors/pass/fail). Of the 2,056 students, 1,192 (58%) responded. In multivariate analyses, students in schools using grading scales with three or more categories had higher levels of stress (beta 2.65; 95% CI 1.54-3.76, P<.0001), emotional exhaustion (beta 5.35; 95% CI 3.34-7.37, P<.0001), and depersonalization (beta 1.36; 95% CI 0.53-2.19, P=.001) and were more likely to have burnout (OR 2.17; 95% CI 1.41-3.35, P=.0005) and to have seriously considered dropping out of school (OR 2.24; 95% CI 1.54-3.27, P<.0001) compared with students in schools using pass/fail grading. There were no relationships between time spent in didactic and clinical experiences and well-being. How students are evaluated has a greater impact than other aspects of curriculum structure on their well-being. Curricular reform intended to enhance student well-being should incorporate pass/fail grading.

  1. Factors associated with failure of oncology drugs in late-stage clinical development: A systematic review.

    PubMed

    Jardim, Denis L; Groves, Eric S; Breitfeld, Philip P; Kurzrock, Razelle

    2017-01-01

    We aimed to describe the reasons for failure of experimental anticancer drugs in late-stage clinical development. We searched the PharmaProjects database (https://citeline.com/products/pharmaprojects/) for anticancer drugs discontinued between 01/01/2009 and 06/30/2014. Drug programs that reached phase III trials, but never gained Food and Drug Administration (FDA) approval were compared to 37 anti-cancer drugs achieving FDA approval in this time period. Forty-two drugs fit our criteria for development failures. These failed drugs (49% targeted, 23% cytotoxics, and 28% other) were tested in 43 cancer indications (drug programs). Only 16% (7/43) of failed drug programs adopted a biomarker-driven rationale for patient selection versus 57% (21/37) of successful drug programs (P<0.001). Phase II trial information was available in 32 of 43 failed drug programs and in 32 of 37 successful programs. Nine of the 32 trials (28%) of failed drugs versus 28 of 32 trials (87%) of successful drugs (P<0.001) achieved proof of concept (single agent response rate (RR) ⩾20% or combination therapy showing a ⩾20% RR increase above the median historical RR without the experimental agent (with a minimal absolute increase of 5%) or a randomized phase II trial showing significance (P⩽0.05) for its primary outcome). No pattern of study sites, trial design or funding characteristics emerged from the failed drug analysis. For drugs that reached Phase III, lack of a biomarker-driven strategy and failure to attain proof of concept in phase II are potential risk factors for later discontinuation, especially for targeted agents. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Clinical utility of the Conners' Continuous Performance Test-II to detect poor effort in U.S. military personnel following traumatic brain injury.

    PubMed

    Lange, Rael T; Iverson, Grant L; Brickell, Tracey A; Staver, Tara; Pancholi, Sonal; Bhagwat, Aditya; French, Louis M

    2013-06-01

    The purpose of this study is to examine the clinical utility of the Conners' Continuous Performance Test (CPT-II) as an embedded marker of poor effort in military personnel undergoing neuropsychological evaluations following traumatic brain injury. Participants were 158 U.S. military service members divided into 3 groups on the basis of brain injury severity and performance (pass/fail) on 2 symptom validity tests: Mild Traumatic Brain Injury (MTBI)-Pass (n = 87), MTBI-Fail (n = 42), and severe traumatic brain injury (STBI)-Pass (n = 29). The MTBI-Fail group performed worse on the majority of CPT-II measures compared with both the MTBI-Pass and STBI-Pass groups. When comparing the MTBI-Fail group and MTBI-Pass groups, the most accurate measure for identifying poor effort was the Commission T score. When selected measures were combined (i.e., Omissions, Commissions, and Perseverations), there was a very small increase in sensitivity (from .26 to .29). When comparing the MTBI-Fail group and STBI-Pass groups, the most accurate measure for identifying poor effort was the Omission and Commissions T score. When selected measures were combined, sensitivity again increased (from .24 to .45). Overall, these results suggest that individual CPT-II measures can be useful for identifying people who are suspected of providing poor effort from those who have provided adequate effort. However, due to low sensitivity and modest negative predictive power values, this measure cannot be used in isolation to detect poor effort, and is largely useful as a test to "rule in," not "rule out" poor effort. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  3. The teaching of fixed partial dentures in undergraduate dental schools in Ireland and the United Kingdom.

    PubMed

    Lynch, C D; Singhrao, H; Addy, L D; Gilmour, A S M

    2010-12-01

    All areas of the practice of dentistry are evolving at a considerable pace. One area in particular which has seen a rapid revolution is the oral rehabilitation of partially dentate adults. The aim of this study was to describe the contemporary teaching of fixed partial dentures (FPDs) in dental schools in Ireland and the United Kingdom. An online questionnaire which sought information in relation to the current teaching of FPDs was developed and distributed to 15 Irish and UK dental schools with undergraduate teaching programmes in Spring 2009. Responses were received from 12 schools (response rate=80%). All schools offer teaching programmes in relation to FPDs. The number of hours devoted to pre-clinical/phantom head teaching of FPDs ranged from 3 to 42h (mean: 16h). The staff/student ratio for pre-clinical teaching courses in FPDs ranged from 1:6 to 1:18 (mode: 1:12). Cantilever resin-retained FPDs were the most popular type of FPD provided clinically (average=0·83 per school; range=1-2). Five schools (42%) report that they have requirements (e.g. targets, quotas, competencies) which students must complete prior to graduation in relation to FPDs. Fixed partial dentures form an important part of the undergraduate teaching programme in UK and Irish dental schools. While this teaching is subjected to contemporary pressures such as lack of curriculum time and a lack of available clinical facilities and teachers, there is evidence that teaching programmes in this area are evolving and are sensitive to current clinical practice trends and evidence-based practice. © 2010 Blackwell Publishing Ltd.

  4. Severe and moderate haemophilia A and B in US females.

    PubMed

    Di Michele, D M; Gibb, C; Lefkowitz, J M; Ni, Q; Gerber, L M; Ganguly, A

    2014-03-01

    Haemophilia A and B are rare X-lined hemorrhagic disorders that typically affect men. Women are usually asymptomatic carriers, but may be symptomatic and, rarely, also express severe (factor VIII (FVIII) or factor IX (FIX) <0.01 U mL(-1)) or moderately severe (FVIII/FIX 0.01-0.05 U mL(-1)) phenotypes. However, data on clinical manifestations, genotype and the psychosocial ramifications of illness in severely affected females remain anecdotal. A national multi-centre retrospective study was conducted to collect a comprehensive data set on affected US girls and women, and to compare clinical observations to previously published information on haemophilic males of comparable severity and mildly affected haemophilic females. Twenty-two severe/moderate haemophilia A/B subjects were characterized with respect to clinical manifestations and disease complications; genetic determinants of phenotypic severity; and health-related quality of life (HR-QoL). Clinical data were compared as previously indicated. Female patients were older than male patients at diagnosis, but similarly experienced joint haemorrhage, disease- and treatment-related complications and access to treatment. Gynaecological and obstetrical bleeding was unexpectedly infrequent. F8 or F9 mutations, accompanied by extremely skewed X-chromosome inactivation pattern (XIP), were primary determinants of severity. HR-QoL was diminished by arthropathy and viral infection. Using systematic case verification of participants in a national surveillance registry, this study elucidated the genetics, clinical phenotype and quality of life issues in female patients with severe/moderate haemophilia. An ongoing international case-controlled study will further evaluate these observations. Novel mechanistic questions are raised about the relationship between XIP and both age and tissue-specific FVIII and FIX expression. © 2014 John Wiley & Sons Ltd.

  5. Clinical Value of Mercaptopurine After Failing Azathioprine Therapy in Patients With Inflammatory Bowel Disease.

    PubMed

    Meijer, Berrie; Seinen, Margien L; Leijte, Niek N W; Mulder, Chris J J; van Bodegraven, Adriaan A; de Boer, Nanne K H

    2016-08-01

    Thiopurines have been widely accepted as immunosuppressive therapy in inflammatory bowel disease. However, many patients have to discontinue thiopurines due to intolerance or ineffectiveness. A therapeutically beneficial effect of switching from azathioprine (AZA) to mercaptopurine (MP) after developing adverse events (AEs) has been reported. The authors assessed the clinical value of MP therapy after AZA discontinuation due to intolerance and, secondary, due to ineffectiveness. In this retrospective single-center study, the authors analyzed data from patients in whom AZA therapy had failed and who were subsequently treated with MP. Thirty-eight patients initiated MP therapy after intolerance to AZA. Intolerance reoccurred in 22 (58%) patients and the remaining 16 (42%) tolerated MP. In 18 out of 48 patients (38%), the AEs that led to discontinuation of MP were similar to those of AZA. A longer duration of prior AZA use was more common in patients who were subsequently tolerant for MP (5.3 versus 1.2 months; P = 0.04). Twenty-two patients discontinued AZA due to ineffectiveness. Eight (36%) patients had clinical benefit from a switch to MP. Six out of these 8 (75%) patients used allopurinol alongside MP, due to ineffectiveness based on a skewed thiopurine metabolism. Patients were more likely to have clinical benefit if the interval between both thiopurines was longer (4.4 versus 0.01 months; P < 0.05). The authors showed that a noteworthy number of patients benefitted therapeutically from a switch from AZA to MP when failing due to intolerance or ineffectiveness; however, the percentage was lower than previously reported in literature.

  6. Histological Assessment of PAXgene Tissue Fixation and Stabilization Reagents

    PubMed Central

    Kap, Marcel; Smedts, Frank; Oosterhuis, Wolter; Winther, Rosa; Christensen, Nanna; Reischauer, Bilge; Viertler, Christian; Groelz, Daniel; Becker, Karl-Friedrich; Zatloukal, Kurt; Langer, Rupert; Slotta-Huspenina, Julia; Bodo, Koppany; de Jong, Bas; Oelmuller, Uwe; Riegman, Peter

    2011-01-01

    Within SPIDIA, an EC FP7 project aimed to improve pre analytic procedures, the PAXgene Tissue System (PAXgene), was designed to improve tissue quality for parallel molecular and morphological analysis. Within the SPIDIA project promising results were found in both genomic and proteomic experiments with PAXgene-fixed and paraffin embedded tissue derived biomolecules. But, for this technology to be accepted for use in both clinical and basic research, it is essential that its adequacy for preserving morphology and antigenicity is validated relative to formalin fixation. It is our aim to assess the suitability of PAXgene tissue fixation for (immuno)histological methods. Normal human tissue specimens (n = 70) were collected and divided into equal parts for fixation either with formalin or PAXgene. Sections of the obtained paraffin-embedded tissue were cut and stained. Morphological aspects of PAXgene-fixed tissue were described and also scored relative to formalin-fixed tissue. Performance of PAXgene-fixed tissue in immunohistochemical and in situ hybridization assays was also assessed relative to the corresponding formalin-fixed tissues. Morphology of PAXgene-fixed paraffin embedded tissue was well preserved and deemed adequate for diagnostics in most cases. Some antigens in PAXgene-fixed and paraffin embedded sections were detectable without the need for antigen retrieval, while others were detected using standard, formalin fixation based, immunohistochemistry protocols. Comparable results were obtained with in situ hybridization and histochemical stains. Basically all assessed histological techniques were found to be applicable to PAXgene-fixed and paraffin embedded tissue. In general results obtained with PAXgene-fixed tissue are comparable to those of formalin-fixed tissue. Compromises made in morphology can be called minor compared to the advantages in the molecular pathology possibilities. PMID:22110732

  7. The method used to set the pass mark in an objective structured clinical examination defines the performance of candidates for certification as rheumatologists.

    PubMed

    Pascual-Ramos, Virginia; Guilaisne Bernard-Medina, Ana; Flores-Alvarado, Diana Elsa; Portela-Hernández, Margarita; Maldonado-Velázquez, María Del Rocío; Jara-Quezada, Luis Javier; Amezcua-Guerra, Luis Manuel; Rubio-Judith López-Zepeda, Nadina E; Álvarez-Hernandez, Everardo; Saavedra, Miguel Ángel; Arce-Salinas, César Alejandro

    The Mexican Accreditation Council for Rheumatology certifies trainees (TR) on an annual basis using both a multiple-choice question (MCQ) test and an objective structured clinical examination (OSCE). For 2013 and 2014, the OSCE pass mark (PM) was set by criterion referencing as ≥6 (CPM), whereas overall rating of borderline performance method (BPM) was added for 2015 and 2016 accreditations. We compared OSCE TR performance according to CPM and BPM, and examined whether correlations between MCQ and OSCE were affected by PM. Forty-three (2015) and 37 (2016) candidates underwent both tests. Altogether, OSCE were integrated by 15 validated stations; one evaluator per station scored TR performance according to a station-tailored check-list and a Likert scale (fail, borderline, above range) of overall performance. A composite OSCE score was derived for each candidate. Appropriate statistics were used. Mean (±standard derivation [SD]) MCQ test scores were 6.6±0.6 (2015) and 6.4±0.6 (2016) with 5 candidates receiving a failing score each year. Mean (±SD) OSCE scores were 7.4±0.6 (2015) and 7.3±0.6 (2016); no candidate received a failing CPM score in either 2015 or 2016 OSCE, although 21 (49%) and 19 (51%) TR, respectively, received a failing BPM score (calculated as 7.3 and 7.4, respectively). Stations for BPM ranged from 4.5 to 9.5; overall, candidates showed better performance in CPM. In all, MCQ correlated with composite OSCE, r=0.67 (2015) and r=0.53 (2016); P≤.001. Trainees with a passing BPM score in OSCE had higher MCQ scores than those with a failing score. Overall, OSCE-PM selection impacted candidates' performance but had a limited affect on correlation between clinical and practical examinations. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  8. Clinical experiences of performing transforaminal balloon adhesiolysis in patients with failed back surgery syndrome: two cases report

    PubMed Central

    Hwang, Bo-Young; Ko, Hong-Seok; Suh, Jeong-Hun; Shin, Jin-Woo; Leem, Jeong-Gill

    2014-01-01

    Epidural fibrosis is a contributing factor to the persistent pain that is associated with failed back surgery syndrome (FBSS) and other pathophysiologies, particularly as it inhibits the passage of regional medications to areas responsible for pain. Therefore, effective mechanical detachment of epidural fibrosis can contribute to pain reduction and improve function in FBSS patients. In this report, we describe the successful treatment of FBSS patients with epidural adhesiolysis using a Fogarty catheter via the transforaminal approach. PMID:24624278

  9. Revision with suture-tape augmentation after failed collateral ligament reconstruction for chronic interphalangeal instability of the hallux.

    PubMed

    Cho, Byung-Ki; Park, Ji-Kang; Choi, Seung-Myung; SooHoo, Nelson F

    2017-12-01

    Chronic varus instability or recurrent subluxation following isolated interphalangeal dislocation of the hallux is a rare injury. No consensus has been reached regarding the best joint-salvage procedure for patients with the failed collateral ligament reconstruction using tendon graft. We report a case who achieved satisfactory clinical outcome through a modified surgical procedure (revision collateral ligament reconstruction augmented with suture-tape). Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  10. Evaluation of Invisalign treatment effectiveness and efficiency compared with conventional fixed appliances using the Peer Assessment Rating index.

    PubMed

    Gu, Jiafeng; Tang, Jack Shengyu; Skulski, Brennan; Fields, Henry W; Beck, F Michael; Firestone, Allen R; Kim, Do-Gyoon; Deguchi, Toru

    2017-02-01

    The purpose of this retrospective case-control study was to compare the treatment effectiveness and efficiency of the Invisalign system with conventional fixed appliances in treating orthodontic patients with mild to moderate malocclusion in a graduate orthodontic clinic. Using the peer assessment rating (PAR) index, we evaluated pretreatment and posttreatment records of 48 Invisalign patients and 48 fixed appliances patients. The 2 groups of patients were controlled for general characteristics and initial severity of malocclusion. We analyzed treatment outcome, duration, and improvement between the Invisalign and fixed appliances groups. The average pretreatment PAR scores (United Kingdom weighting) were 20.81 for Invisalign and 22.79 for fixed appliances (P = 1.0000). Posttreatment weighted PAR scores between Invisalign and fixed appliances were not statistically different (P = 0.7420). On average, the Invisalign patients finished 5.7 months faster than did those with fixed appliances (P = 0.0040). The weighted PAR score reduction with treatment was not statistically different between the Invisalign and fixed appliances groups (P = 0.4573). All patients in both groups had more than a 30% reduction in the PAR scores. Logistic regression analysis indicated that the odds of achieving "great improvement" in the Invisalign group were 0.329 times the odds of achieving "great improvement" in the fixed appliances group after controlling for age (P = 0.0150). Our data showed that both Invisalign and fixed appliances were able to improve the malocclusion. Invisalign patients finished treatment faster than did those with fixed appliances. However, it appears that Invisalign may not be as effective as fixed appliances in achieving "great improvement" in a malocclusion. This study might help clinicians to determine appropriate patients for Invisalign treatment. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  11. High-resolution MR imaging for dental impressions: a feasibility study.

    PubMed

    Boldt, Julian; Rottner, Kurt; Schmitter, Marc; Hopfgartner, Andreas; Jakob, Peter; Richter, Ernst-Jürgen; Tymofiyeva, Olga

    2018-04-01

    Magnetic resonance imaging is an emerging technology in dental medicine. While low-resolution MRI has especially provided means to examine the temporomandibular joint due to its anatomic inaccessibility, it was the goal of this study to assess whether high-resolution MRI is capable of delivering a dataset sufficiently precise enough to serve as digital impression of human teeth. An informed and consenting patient in need of dental restoration with fixed partial dentures was chosen as subject. Two prepared teeth were measured using MRI and the dataset subjected to mathematical processing before Fourier transformation. After reconstruction, a 3D file was generated which was fed into an existing industry standard CAD/CAM process. A framework for a fixed dental prosthesis was digitally modeled and manufactured by laser-sintering. The fit in situ was found to be acceptable by current clinical standards, which allowed permanent placement of the fixed prosthesis. Using a clinical whole-body MR scanner with the addition of custom add-on hardware, contrast enhancement, and data post-processing, resolution and signal-to-noise ratio were sufficiently achieved to allow fabrication of a dental restoration in an acquisition time comparable to the setting time of common dental impression materials. Furthermore, the measurement was well tolerated. The herein described method can be regarded as proof of principle that MRI is a promising option for digital impressions when fixed partial dentures are required.

  12. Prevention and Treatment of White Spot Lesions During and After Treatment with Fixed Orthodontic Appliances: a Systematic Literature Review.

    PubMed

    Lopatiene, Kristina; Borisovaite, Marija; Lapenaite, Egle

    2016-01-01

    The aim of the systematic literature review is to update the evidence for the prevention of white spot lesions, using materials containing fluoride and/or casein phosphopeptide-amorphous calcium phosphate during and after treatment with fixed orthodontic appliances. Information search for controlled studies on humans published between January 2008 and February 2016 was performed in PubMed, ScienceDirect, Embase, The Cochrane Library. Inclusion criteria were: the English language, study on humans, patients undergoing orthodontic treatment with fixed appliances, randomized or quasi-randomized controlled clinical studies fluoride-containing product or casein derivates used throughout the appliance therapy or straightaway after debonding. 326 articles were reviewed (Embase 141, PubMed 129, ScienceDirect 41, Cochrane 15). Twelve clinical studies fulfilled all inclusion criteria. Use of fluoridated toothpaste had a remineralizing effect on white spot lesions (WSLs) (P < 0.05); fluoride varnish and casein supplements were effective in prevention and early treatment of WSLs (P < 0.05). Early detection of white spot lesions during orthodontic treatment would allow implementing preventive measures to control the demineralization process before lesions progress. The systemic review has showed that the usage of fluoride and casein supplements in ameliorating white spot lesions during and after fixed orthodontic treatment is significantly effective. However the use of casein phosphopeptide-amorphous calcium phosphate can be more beneficial than fluoride rinse in the reduction of demineralization spots.

  13. Efficacy of professional hygiene and prophylaxis on preventing plaque increase in orthodontic patients with multibracket appliances: a systematic review.

    PubMed

    Migliorati, Marco; Isaia, Luisa; Cassaro, Angela; Rivetti, Alessandro; Silvestrini-Biavati, Francesca; Gastaldo, Laura; Piccardo, Ilaria; Dalessandri, Domenico; Silvestrini-Biavati, Armando

    2015-06-01

    Plaque increase is a troubling side-effect of fixed orthodontic therapy. This generally arise as a consequence of long-term difficulty in maintaining adequate oral hygiene while wearing multibracket appliances. Demineralization, also known as white spot, causes particular concern as it spoils the aesthetic outcome of the treatment itself, not to mention the integrity of the enamel. To collate the existing literature by evaluating the efficacy of dental hygienist intervention on plaque increase in fixed orthodontics patients. A targeted search of the Medline database (Entrez PubMed), EMBASE, and CENTRAL using relevant Medical Subject Headings was performed. The articles selected were all published before June 2013 and comprised randomized clinical trials, prospective longitudinal controlled clinical trials, and before/after studies onto the plaque increase of fixed appliances. The search strategy yielded 630 articles. Following the application of inclusion and exclusion criteria, 10 articles qualified for the final review. The quality of the retrieved researches ranged from low (one study) to high (one study). Six controlled trials were considered at unknown risk of bias. Data showed that regular patient motivation sessions and mechanical tooth cleaning by a professional dental hygienist help maintaining good oral hygiene during fixed orthodontics. © The Author 2014. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  14. Failure Rates of Orthodontic Fixed Lingual Retainers bonded with Two Flowable Light-cured Adhesives: A Comparative Prospective Clinical Trial.

    PubMed

    Talic, Nabeel F

    2016-08-01

    This comparative prospective randomized clinical trial examined the in vivo failure rates of fixed mandibular and maxillary lingual retainers bonded with two light-cured flowable composites over 6 months. Consecutive patients were divided into two groups on a 1:1 basis. Two hundred fixed lingual retainers were included, and their failures were followed for 6 months. One group (n = 50) received retainers bonded with a nano-hybrid composite based on nano-optimized technology (Tetric-N-Flow, Ivoclar Vivadent). Another group (n = 50) received retainers bonded with a low viscosity (LV) composite (Transbond Supreme LV, 3M Unitek). There was no significant difference between the overall failure rates of mandibular retainers bonded with Transbond (8%) and those bonded with Tetric-N-Flow (18%). However, the odds ratio for failure using Tetric-N-flow was 2.52-fold greater than that of Transbond. The failure rate of maxillary retainers bonded with Transbond was higher (14%), but not significantly different, than that of maxillary retainers bonded with Tetric-N-flow (10%). There was no significant difference in the estimated mean survival times of the maxillary and mandibular retainers bonded with the two composites. Both types of composites tested in the current study can be used to bond fixed maxillary and mandibular lingual retainers, with low failure rates.

  15. Outcomes Assessment of Treating Completely Edentulous Patients with a Fixed Implant-Supported Profile Prosthesis Utilizing a Graftless Approach. Part 1: Clinically Related Outcomes.

    PubMed

    Alzoubi, Fawaz; Bedrossian, Edmond; Wong, Allen; Farrell, Douglas; Park, Chan; Indresano, Thomas

    To assess outcomes of treating completely edentulous patients with a fixed implant-supported profile prosthesis utilizing a graftless approach for the maxilla and for the mandible, with emphasis on clinically related outcomes, specifically implant and prosthesis survival. This was a retrospective study with the following inclusion criteria: completely edentulous patients rehabilitated with a fixed implant-supported profile denture utilizing a graftless approach. Patients fulfilling the inclusion criteria were asked to participate in the study during their follow-up visits, and hence a consecutive sampling strategy was used. Data regarding implant and prosthesis cumulative survival rates (CSRs) were gathered and calculated. Thirty-four patients were identified with a total of 220 implants placed. An overall CSR of 98.2% was recorded with an observation of up to 10 years. For tilted, axial, and zygomatic implants, CSRs of 96.9%, 98.0%, and 100%, respectively, were observed for up to 10 years. For provisional prostheses, CSRs of 92.3% at 1 year, and 84.6% at 2 years were observed. For final prostheses, a CSR of 93.8% was observed at 10 years. The results suggest that treating completely edentulous patients with a fixed profile prosthesis utilizing a graftless approach in the maxilla and the mandible can be a reliable treatment option.

  16. Comparison of long-term safety of fixed-dose combinations azilsartan medoxomil/chlorthalidone vs olmesartan medoxomil/hydrochlorothiazide.

    PubMed

    Neutel, Joel M; Cushman, William C; Lloyd, Eric; Barger, Bruce; Handley, Alison

    2017-09-01

    This 52-week, randomized, open-label study evaluated long-term safety/tolerability of fixed-dose combination azilsartan medoxomil/chlorthalidone (AZL-M/CLD) vs fixed-dose combination olmesartan medoxomil/hydrochlorothiazide (OLM/HCTZ) in patients with essential hypertension (stage 2; clinic systolic blood pressure 160-190 mm Hg). Initial AZL-M/CLD 40/12.5 mg/d (n=418) or OLM/HCTZ 20/12.5 mg/d (n=419) could be uptitrated during weeks 4 to 52 (AZL-M/CLD to 80/25 mg; OLM/HCTZ to 40/25 mg [United States] or 20/25 mg [Europe]) to meet blood pressure targets. Treatment-emergent adverse events/serious adverse events occurred in 78.5%/5.7% of patients taking AZL-M/CLD vs 76.4%/6.2% taking OLM/HCTZ. The most frequent adverse events were dizziness (16.3% vs 12.6%), blood creatinine increase (21.5% vs 8.6%), headache (7.4% vs 11.0%), and nasopharyngitis (12.2% vs 11.5%). Hypokalemia was uncommon (1.0% vs 0.7%). Greater blood pressure reductions with AZL-M/CLD by week 2 were maintained throughout the study, despite less uptitration (32.3% vs 48.9% with OLM/HCTZ). Fixed-dose combination AZL-M/CLD showed an encouraging benefit-risk profile when used per standard clinical practice in a titrate-to-target strategy. ©2017 Wiley Periodicals, Inc.

  17. Impact of Image Noise on Gamma Index Calculation

    NASA Astrophysics Data System (ADS)

    Chen, M.; Mo, X.; Parnell, D.; Olivera, G.; Galmarini, D.; Lu, W.

    2014-03-01

    Purpose: The Gamma Index defines an asymmetric metric between the evaluated image and the reference image. It provides a quantitative comparison that can be used to indicate sample-wised pass/fail on the agreement of the two images. The Gamma passing/failing rate has become an important clinical evaluation tool. However, the presence of noise in the evaluated and/or reference images may change the Gamma Index, hence the passing/failing rate, and further, clinical decisions. In this work, we systematically studied the impact of the image noise on the Gamma Index calculation. Methods: We used both analytic formulation and numerical calculations in our study. The numerical calculations included simulations and clinical images. Three different noise scenarios were studied in simulations: noise in reference images only, in evaluated images only, and in both. Both white and spatially correlated noises of various magnitudes were simulated. For clinical images of various noise levels, the Gamma Index of measurement against calculation, calculation against measurement, and measurement against measurement, were evaluated. Results: Numerical calculations for both the simulation and clinical data agreed with the analytic formulations, and the clinical data agreed with the simulations. For the Gamma Index of measurement against calculation, its distribution has an increased mean and an increased standard deviation as the noise increases. On the contrary, for the Gamma index of calculation against measurement, its distribution has a decreased mean and stabilized standard deviation as the noise increases. White noise has greater impact on the Gamma Index than spatially correlated noise. Conclusions: The noise has significant impact on the Gamma Index calculation and the impact is asymmetric. The Gamma Index should be reported along with the noise levels in both reference and evaluated images. Reporting of the Gamma Index with switched roles of the images as reference and evaluated images or some composite metrics would be a good practice.

  18. Transvaginal ultrasonographic cervical measurement in predicting failed labor induction and cesarean delivery for failure to progress in nulliparous women.

    PubMed

    Park, Kyo Hoon

    2007-08-01

    The aim of this study was to evaluate the value of transvaginal sonographic cervical measurement in predicting failed labor induction and cesarean delivery for failure to progress in nulliparous women. One hundred and sixty-one women scheduled for labor induction underwent transvaginal ultrasonography and digital cervical examinations. Logistic regression demonstrated that cervical length and gestational age at induction, but not the Bishop score, significantly and independently predicted failed labor induction. According to the receiver operating characteristic curves analysis, the best cut-off value of cervical length for predicting failed labor induction was 28 mm, with a sensitivity of 62% and a specificity of 60%. In terms of the likelihood of a cesarean delivery for failure to progress as the outcome variable, logistic regression indicated that maternal height and birth weight, but not cervical length or Bishop score, were significantly and independently associated with an increased risk of cesarean delivery for failure to progress. Transvaginal sonographic measurements of cervical length thus independently predicted failed labor induction in nulliparous women. However, the relatively poor predictive performance of this test undermines its clinical usefulness as a predictor of failed labor induction. Moreover, cervical length appears to have a poor predictive value for the likelihood of a cesarean delivery for failure to progress.

  19. Quality of anti-malarials collected in the private and informal sectors in Guyana and Suriname

    PubMed Central

    2012-01-01

    Background Despite a significant reduction in the number of malaria cases in Guyana and Suriname, this disease remains a major problem in the interior of both countries, especially in areas with gold mining and logging operations, where malaria is endemic. National malaria control programmes in these countries provide treatment to patients with medicines that are procured and distributed through regulated processes in the public sector. However, availability to medicines in licensed facilities (private sector) and unlicensed facilities (informal sector) is common, posing the risk of access to and use of non-recommended treatments and/or poor quality products. Methods To assess the quality of circulating anti-malarial medicines, samples were purchased in the private and informal sectors of Guyana and Suriname in 2009. The sampling sites were selected based on epidemiological data and/or distance from health facilities. Samples were analysed for identity, content, dissolution or disintegration, impurities, and uniformity of dosage units or weight variation according to manufacturer, pharmacopeial, or other validated method. Results Quality issues were observed in 45 of 77 (58%) anti-malarial medicines sampled in Guyana of which 30 failed visual & physical inspection and 18 failed quality control tests. The proportion of monotherapy and ACT medicines failing quality control tests was 43% (13/30) and 11% (5/47) respectively. A higher proportion of medicines sampled from the private sector 34% (11/32) failed quality control tests versus 16% (7/45) in the informal sector. In Suriname, 58 medicines were sampled, of which 50 (86%) were Artecom®, the fixed-dose combination of piperaquine-dihydroartemisinin-trimethoprim co-blistered with a primaquine phosphate tablet. All Artecom samples were found to lack a label claim for primaquine, thus failing visual and physical inspection. Conclusions The findings of the studies in both countries point to significant problems with the quality of anti-malarial medicines available in private and informal sector facilities as well as the availability of therapy not compliant with national treatment guidelines. They also stress the need to strengthen regulatory control efforts on the availability of anti-malarial medicines in these sectors and in endemic areas. PMID:22704709

  20. A prospective, randomised, controlled, multi-centre comparative effectiveness study of healing using dehydrated human amnion/chorion membrane allograft, bioengineered skin substitute or standard of care for treatment of chronic lower extremity diabetic ulcers.

    PubMed

    Zelen, Charles M; Gould, Lisa; Serena, Thomas E; Carter, Marissa J; Keller, Jennifer; Li, William W

    2015-12-01

    A prospective, randomised, controlled, parallel group, multi-centre clinical trial was conducted at three sites to compare the healing effectiveness of treatment of chronic lower extremity diabetic ulcers with either weekly applications of Apligraf(®) (Organogenesis, Inc., Canton, MA), EpiFix(®) (MiMedx Group, Inc., Marietta, GA), or standard wound care with collagen-alginate dressing. The primary study outcome was the percent change in complete wound healing after 4 and 6 weeks of treatment. Secondary outcomes included percent change in wound area per week, velocity of wound closure and a calculation of the amount and cost of Apligraf or EpiFix used. A total of 65 subjects entered the 2-week run-in period and 60 were randomised (20 per group). The proportion of patients in the EpiFix group achieving complete wound closure within 4 and 6 weeks was 85% and 95%, significantly higher (all adjusted P-values ≤ 0·003) than for patients receiving Apligraf (35% and 45%), or standard care (30% and 35%). After 1 week, wounds treated with EpiFix had reduced in area by 83·5% compared with 53·1% for wounds treated with Apligraf. Median time to healing was significantly faster (all adjusted P-values ≤0·001) with EpiFix (13 days) compared to Apligraf (49 days) or standard care (49 days). The mean number of grafts used and the graft cost per patient were lower in the EpiFix group campared to the Apligraf group, at 2·15 grafts at a cost of $1669 versus 6·2 grafts at a cost of $9216, respectively. The results of this study demonstrate the clinical and resource utilisation superiority of EpiFix compared to Apligraf or standard of care, for the treatment of diabetic ulcers of the lower extremities. © 2014 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  1. A phase I/II trial of AT9283, a selective inhibitor of aurora kinase in children with relapsed or refractory acute leukemia: challenges to run early phase clinical trials for children with leukemia.

    PubMed

    Vormoor, B; Veal, G J; Griffin, M J; Boddy, A V; Irving, J; Minto, L; Case, M; Banerji, U; Swales, K E; Tall, J R; Moore, A S; Toguchi, M; Acton, G; Dyer, K; Schwab, C; Harrison, C J; Grainger, J D; Lancaster, D; Kearns, P; Hargrave, D; Vormoor, J

    2017-06-01

    Aurora kinases regulate mitosis and are commonly overexpressed in leukemia. This phase I/IIa study of AT9283, a multikinase inhibitor, was designed to identify maximal tolerated doses, safety, pharmacokinetics, and pharmacodynamic activity in children with relapsed/refractory acute leukemia. The trial suffered from poor recruitment and terminated early, therefore failing to identify its primary endpoints. AT9283 caused tolerable toxicity, but failed to show clinical responses. Future trials should be based on robust preclinical data that provide an indication of which patients may benefit from the experimental agent, and recruitment should be improved through international collaborations and early combination with established treatment strategies. © 2016 Wiley Periodicals, Inc.

  2. Infliximab to treat severe ulcerative colitis

    PubMed Central

    Cury, Dídia Bisamra; de Souza Cury, Marcelo; Elias, Geraldo Vinicius Hemerly; Mizsputen, Sender Jankiel

    2009-01-01

    A 48-year-old female with severe ulcerative colitis refractory to conventional therapy was referred to our facility for management. The patient showed extensive ulcerative colitis since the age of 20 years and had failed therapy with 5-aminosalicylic acid agents and azathioprine. The disease remained active despite treatment with steroids and cyclosporine. The clinical and endoscopic parameters were consistent with severe disease. Infectious precipitants were ruled out. Given the severity of the disease and in order to avoid a colectomy, we started the patient on infliximab therapy. A dramatic clinical and endoscopic response was observed and she remained in remission at the end of a 1-year follow-up period. We discuss findings in the literature regarding the use of infliximab therapy in patients with ulcerative colitis who have failed steroids and cyclosporine. PMID:19360923

  3. Different femorotibial contact points between fixed- and mobile-bearing TKAs do not show clinical impact.

    PubMed

    van Stralen, R A; Heesterbeek, P J C; Wymenga, A B

    2015-11-01

    In anteroposterior (AP)-gliding mobile-bearing total knee arthroplasty (TKA), the femoral component can theoretically slide forward resulting in a more anterior contact point, causing pain due to impingement. A lower lever arm of the extensor apparatus can also attribute to higher patella pressures and pain. The goal of this study was to determine the contact point in a cohort of mobile- and fixed-bearing TKAs, to determine whether the contact point lies more anteriorly in mobile-bearing TKA and to confirm whether this results in anterior knee pain. We used 38 fixed-bearing TKA and 40 mobile-bearing TKA from a randomized trial with straight lateral knee X-rays and measured the contact point. The functional outcome was measured by Knee Society Score at 12 months postoperatively. Pain scores were analysed using a VAS score (0-100 mm) in all patients at rest and when moving. Difficulty at rising up out of a chair was also assessed using a VAS score. The contact point in mobile-bearing TKA was situated at 59.5 % of the AP distance of the tibia and in the fixed-bearing TKA group at 66.1 % (P< 0.05). Patients with mobile- and fixed-bearing TKAs had similar knee scores, pain scores and difficulty in chair rise. No significant correlation was found between contact point and knee pain. The hypothesis of a more anterior contact point in the mobile-bearing cohort was confirmed but no correlation with functional and pain scores in this cohort could be found. The tibiofemoral contact point could not be correlated with a different clinical outcome and higher incidence of anterior knee pain. This study further adds to the knowledge on possible differences between mobile- and fixed-bearing prostheses. Next to that, bad outcomes could not be explained by CP. Case series, Level IV.

  4. [Fixed-dose combination fluticasone propionate/formoterol for the treatment of asthma: a review of its pharmacology, efficacy and tolerability].

    PubMed

    Quintano Jiménez, J A; Ginel Mendoza, L; Entrenas Costa, L M; Polo García, J

    2016-02-01

    The fixed-dose combination fluticasone propionate/formoterol (FPF) is a novel combination of a widely known and used inhaled glucocorticoid (IGC) and a long-acting β2-adrenergic agonist (LABA), available for the first time in a single device. This fixed-dose combination of FPF has a demonstrated efficacy and safety profile in clinical trials compared with its individual components and other fixed-dose combinations of IGC/LABA and is indicated for the treatment of persistent asthma in adults and adolescents. FPF is available in a wide range of doses that can adequately cover the therapeutic steps recommended by treatment guidelines, constituting a fixed-dose combination of GCI/LABA that is effective, rapid, well tolerated and with a reasonable acquisition cost. Various assessment agencies of the Spanish Autonomous Communities consider this combination to be an appropriate alternative therapy for asthma in the primary care setting. Copyright © 2016 Elsevier España, S.L.U. y Sociedad Española de Medicina Rural y Generalista (SEMERGEN). All rights reserved.

  5. Outcome of Unicompartmental Knee Arthroplasty: A Systematic Review of Comparative Studies between Fixed and Mobile Bearings Focusing on Complications

    PubMed Central

    Ko, Young-Bong; Gujarathi, Manan Ramesh

    2015-01-01

    The purpose of this systematic review is to collate results of studies comparing fixed and mobile bearing unicompartmental knee arthroplasty (UKA), focusing on complications and timing for reoperations. Out of 723 results derived from PubMed, EMBASE and Cochrane database search engines on bearings in arthroplasty, 10 studies comparing clinical results of fixed bearings to mobile bearings in UKA were found eligible for analysis. The reoperation rate was calculated using a novel method such as reoperations per hundred component years, and the causes of specific reoperations were investigated. The overall reoperation rate per hundred component years was similar between the mobile bearings (1.392) and fixed bearings (1.377); however, mobile bearings were more susceptible to reoperations in cases with aseptic loosening (0.393>0.255), progression of arthritis (0.428>0.357) and implant dislocation (0.286>0). The overall incidence of complications is similar for fixed and mobile bearing designs in UKA. The discussion on complications presented above may assist surgeons in their choice of bearing design. PMID:26389066

  6. Successful transduction of liver in hemophilia by AAV-Factor IX and limitations imposed by the host immune response.

    PubMed

    Manno, Catherine S; Pierce, Glenn F; Arruda, Valder R; Glader, Bertil; Ragni, Margaret; Rasko, John J; Rasko, John; Ozelo, Margareth C; Hoots, Keith; Blatt, Philip; Konkle, Barbara; Dake, Michael; Kaye, Robin; Razavi, Mahmood; Zajko, Albert; Zehnder, James; Rustagi, Pradip K; Nakai, Hiroyuki; Chew, Amy; Leonard, Debra; Wright, J Fraser; Lessard, Ruth R; Sommer, Jürg M; Tigges, Michael; Sabatino, Denise; Luk, Alvin; Jiang, Haiyan; Mingozzi, Federico; Couto, Linda; Ertl, Hildegund C; High, Katherine A; Kay, Mark A

    2006-03-01

    We have previously shown that a single portal vein infusion of a recombinant adeno-associated viral vector (rAAV) expressing canine Factor IX (F.IX) resulted in long-term expression of therapeutic levels of F.IX in dogs with severe hemophilia B. We carried out a phase 1/2 dose-escalation clinical study to extend this approach to humans with severe hemophilia B. rAAV-2 vector expressing human F.IX was infused through the hepatic artery into seven subjects. The data show that: (i) vector infusion at doses up to 2 x 10(12) vg/kg was not associated with acute or long-lasting toxicity; (ii) therapeutic levels of F.IX were achieved at the highest dose tested; (iii) duration of expression at therapeutic levels was limited to a period of approximately 8 weeks; (iv) a gradual decline in F.IX was accompanied by a transient asymptomatic elevation of liver transaminases that resolved without treatment. Further studies suggested that destruction of transduced hepatocytes by cell-mediated immunity targeting antigens of the AAV capsid caused both the decline in F.IX and the transient transaminitis. We conclude that rAAV-2 vectors can transduce human hepatocytes in vivo to result in therapeutically relevant levels of F.IX, but that future studies in humans may require immunomodulation to achieve long-term expression.

  7. P protein in the phloem of Cucurbita. II. The P protein of mature sieve elements.

    PubMed

    Cronshaw, J; Esau, K

    1968-08-01

    During maturation of sieve elements in Cucurbita maxima Duchesne, the P-protein bodies (slime bodies) usually disperse in the tonoplast-free cell. In some sieve elements the P-protein bodies fail to disperse. The occurrence of dispersal or nondispersal of P-protein bodies can be related to the position of the sieve elements in the stem or petiole. In the sieve elements within the vascular bundle the bodies normally disperse; in the extrafascicular sieve elements the bodies often fail to disperse. Extrafascicular sieve elements showing partial dispersal also occur. The appearance of the sieve plate in fixed material is related to the degree of dispersal or nondispersal of the P-protein bodies. In sieve elements in which complete dispersal occurs the sieve plate usually has a substantial deposit of callose, and the sieve-plate pores are filled with P protein. In sieve elements containing nondispersing P-protein bodies the sieve plate bears little or no callose, and its pores usually are essentially "open." The dispersed P-protein components may aggregate into loosely organized "strands," which sometimes extend vertically through the cell and continue through the sieve-plate pores; but they may be oriented otherwise in the cell, even transversely.

  8. Resilient health care: turning patient safety on its head.

    PubMed

    Braithwaite, Jeffrey; Wears, Robert L; Hollnagel, Erik

    2015-10-01

    The current approach to patient safety, labelled Safety I, is predicated on a 'find and fix' model. It identifies things going wrong, after the event, and aims to stamp them out, in order to ensure that the number of errors is as low as possible. Healthcare is much more complex than such a linear model suggests. We need to switch the focus to what we have come to call Safety II: a concerted effort to enable things to go right more often. The key is to appreciate that healthcare is resilient to a large extent, and everyday performance succeeds much more often than it fails. Clinicians constantly adjust what they do to match the conditions. Facilitating work flexibility, and actively trying to increase the capacity of clinicians to deliver more care more effectively, is key to this new paradigm. At its heart, proactive safety management focuses on how everyday performance usually succeeds rather than on why it occasionally fails, and actively strives to improve the former rather than simply preventing the latter. © The Author 2015. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  9. P PROTEIN IN THE PHLOEM OF CUCURBITA

    PubMed Central

    Cronshaw, James; Esau, Katherine

    1968-01-01

    During maturation of sieve elements in Cucurbita maxima Duchesne, the P-protein bodies (slime bodies) usually disperse in the tonoplast-free cell. In some sieve elements the P-protein bodies fail to disperse. The occurrence of dispersal or nondispersal of P-protein bodies can be related to the position of the sieve elements in the stem or petiole. In the sieve elements within the vascular bundle the bodies normally disperse; in the extrafascicular sieve elements the bodies often fail to disperse. Extrafascicular sieve elements showing partial dispersal also occur. The appearance of the sieve plate in fixed material is related to the degree of dispersal or nondispersal of the P-protein bodies. In sieve elements in which complete dispersal occurs the sieve plate usually has a substantial deposit of callose, and the sieve-plate pores are filled with P protein. In sieve elements containing nondispersing P-protein bodies the sieve plate bears little or no callose, and its pores usually are essentially "open." The dispersed P-protein components may aggregate into loosely organized "strands," which sometimes extend vertically through the cell and continue through the sieve-plate pores; but they may be oriented otherwise in the cell, even transversely. PMID:5664205

  10. Learning of Musculoskeletal Ligament Stress Testing in a Gross Anatomy Laboratory

    ERIC Educational Resources Information Center

    Krause, David A.; Youdas, James W.; Hollman, John H.

    2011-01-01

    Human anatomy in physical therapy programs is a basic science course serving as a foundation for subsequent clinical courses. Integration of anatomy with a clinical emphasis throughout a curriculum provides opportunities for reinforcement of previously learned material. Considering the human cadaver laboratory as a fixed cost to our program, we…

  11. The practice of evidence-based medicine involves the care of whole persons.

    PubMed

    Richardson, W Scott

    2017-04-01

    In this issue of the Journal, Dr. Fava posits that evidence-based medicine (EBM) was bound to fail. I share some of the concerns he expresses, yet I see more reasons for optimism. Having been on rounds with both Drs. Engel and Sackett, I reckon they would have agreed more than they disagreed. Their central teaching was the compassionate and well-informed care of sick persons. The model that emerged from these rounds was that patient care could be both person-centered and evidence-based, that clinical judgment was essential to both, and the decisions could and should be shared. Both clinicians and patients can bring knowledge from several sources into the shared decision making process in the clinical encounter, including evidence from clinical care research. I thank Dr. Fava for expressing legitimate doubts and providing useful criticism, yet I am cautiously optimistic that the model of EBM described here is robust enough to meet the challenges and is not doomed to fail. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Scedosporium apiospermum: a rare cause of malignant otitis externa.

    PubMed

    McLaren, Oliver; Potter, Christian

    2016-09-09

    A 79-year-old man, with a history of well-controlled diabetes mellitus, presented with left-sided otalgia. With an initial diagnosis of simple otitis externa, he was discharged on topical drops. He represented 2 months later with worsening otalgia and discharge. A diagnosis of malignant otitis externa was made based on clinical and radiological findings. Intravenous Tazocin and Gentamicin were given based on previous bacterial culture from ear swabs. The patient failed to improve and developed left-sided facial nerve palsy. His condition stabilised following a change in antimicrobial therapy and his management continued in the community on intravenous Meropenem with twice weekly aural toilet. Repeated nuclear medicine imaging failed to demonstrate resolution. A bony sequestration was removed from the external auditory canal in the outpatient clinic, which following extended culture grew Scedosporium apiospermum; his management was subsequently changed to oral Voriconazole. This led to rapid clinical improvement and disease resolution over a 6 -week period. 2016 BMJ Publishing Group Ltd.

  13. Analysis of defects in ProTaper hand-operated instruments after clinical use.

    PubMed

    Shen, Ya; Bian, Zhuan; Cheung, Gary Shun-pan; Peng, Bin

    2007-03-01

    The purpose of this study was to analyze the type and location of defects observed in ProTaper for Hand Use (PHU) instruments after routine clinical use. We analyzed a total of 401 PHUs discarded from an endodontic clinic over a 17-month period. Those failed instruments were examined on the lateral and fractographic surface by scanning electron microscope. Of the 86 PHUs that showed discernible defects, 28 were intact but partially unwound, and 58 were fractured (36 because of shear and 22 from fatigue failure). The primary characteristic of shear failure was the presence of a skewed dimple and/or tear ridge, a typical pattern developed because of a combination of various loads. Nearly 74% of the instruments with defects exhibited shear damage. About three-quarters of the instrument fractures occurred in the apical one-third of the canal, mostly in molars. The results of this study indicated that most PHU instruments fail because of either shear or fatigue.

  14. Bridging knee arthrodesis for limb salvage using an intramedullary cemented nail: a retrospective outcome analysis of a case series.

    PubMed

    Neuerburg, Carl; Bieger, Ralf; Jung, Sebastian; Kappe, Thomas; Reichel, Heiko; Decking, Ralf

    2012-08-01

    Failed total knee replacement with compromised bone and soft-tissues can be challenging. In these situations, arthrodesis remains a treatment option of a limb-saving procedure. We investigated the outcome of treatment with an intramedullary cemented knee arthrodesis nail implanted in 22 consecutive patients with forlorn situations after failed total knee replacement. There were three major complications due to re-infection and two minor complications due to wound-healing disturbances that healed with the implant retained after an average follow-up of 3.4 years. Clinical examination, Short Form-36 and Oxford knee scores revealed low pain levels, safe implant anchorage, and improved stability of the knee, whilst autonomous mobility utilizing walking aids was still possible. Bridging knee arthrodesis with an intramedullary nail is a valuable salvage procedure with acceptable clinical results. As recurring infection remains the most challenging complication, regular clinical and radiological follow-up examinations are necessary following implant-related knee arthrodesis to allow timely intervention in case of loosening.

  15. Management of the failed biaxial wrist replacement.

    PubMed

    Talwalkar, S C; Hayton, M J; Trail, I A; Stanley, J K

    2005-06-01

    Nine cases of failed biaxial wrist replacement underwent revision surgery and subsequent clinical and radiographic assessment at a mean follow-up of 28 months. Clinical assessment included the hospital for special surgery (HSS) and activities of daily living scoring systems. Five patients had a revision biaxial wrist replacement, three had wrist fusions and two underwent an excision arthroplasty. The mean HSS score was 73 for the revision biaxial replacements, 63 for the wrist fusions and 92 for the excision arthroplasties. The mean activities for daily living score was 16 for the revision biaxial replacements, 14 for the wrist fusion and 20 for the excision arthroplasties. Despite the experience of implant failure, six patients would still choose a primary wrist replacement again. All patients in this small series appear to have had good clinical outcomes. Revision to another wrist replacement appears no worse than a wrist fusion in the short term and patients value the preservation of movement that an implant offers.

  16. Achilles Tendinopathy: Current Concepts about the Basic Science and Clinical Treatments

    PubMed Central

    Li, Hong-Yun

    2016-01-01

    Achilles tendinopathy is one of the most frequently ankle and foot overuse injuries, which is a clinical syndrome characterized by the combination of pain, swelling, and impaired performance. The two main categories of Achilles tendinopathy are classified according to anatomical location and broadly include insertional and noninsertional tendinopathy. The etiology of Achilles tendinopathy is multifactorial including both intrinsic and extrinsic factors. Failed healing response and degenerative changes were found in the tendon. The failed healing response includes three different and continuous stages (reactive tendinopathy, tendon disrepair, and degenerative tendinopathy). The histological studies have demonstrated an increased number of tenocytes and concentration of glycosaminoglycans in the ground substance, disorganization and fragmentation of the collagen, and neovascularization. There are variable conservative and surgical treatment options for Achilles tendinopathy. However, there has not been a gold standard of these treatments because of the controversial clinical results between various studies. In the future, new level I researches will be needed to prove the effect of these treatment options. PMID:27885357

  17. The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture.

    PubMed

    Ercoli, Carlo; Geminiani, Alessandro; Feng, Changyong; Lee, Heeje

    2012-05-01

    The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant-supported full-arch prosthesis framework is fabricated with or without the aid of a verification jig. This investigation was approved by the University of Rochester Research Subject Review Board (protocol #RSRB00038482). Thirty edentulous patients, 49 to 73 years old (mean 61 years old), rehabilitated with a nonsegmented fixed implant-supported complete denture were included in the study. During the restorative process, final impressions were made using the pickup impression technique and elastomeric impression materials. For 16 patients, a verification jig was made (group J), while for the remaining 14 patients, a verification jig was not used (group NJ) and the framework was fabricated directly on the master cast. During the framework try-in appointment, the fit was assessed by clinical (Sheffield test) and radiographic inspection and recorded as passive or nonpassive. When a verification jig was used (group J, n = 16), all frameworks exhibited clinically passive fit, while when a verification jig was not used (group NJ, n = 14), only two frameworks fit. This difference was statistically significant (p < .001). Within the limitations of this retrospective study, the fabrication of a verification jig ensured clinically passive fit of metal frameworks in nonsegmented fixed implant-supported complete denture. © 2011 Wiley Periodicals, Inc.

  18. Systematic review of outcomes following fixed angle intramedullary fixation of distal radius fractures.

    PubMed

    Hardman, John; Al-Hadithy, Nawfal; Hester, Thomas; Anakwe, Raymond

    2015-12-01

    There remains little consensus regarding the optimal management of distal radius fractures. Fixed angle volar devices have gained recent popularity, but have also been associated with soft tissue complications. Intramedullary (IM) devices offer fixed angle stabilisation with minimally invasive surgical technique and low, IM profile. No formal review of outcomes could be identified. We conducted a systematic review of clinical studies regarding the use of fixed angle IM devices in acute extra-articular or simple intra-articular distal radius fractures. Preferred Reporting Items for Systematic Reviews (PRISMA) guidance was followed. Numerical data regarding functional scores, ranges of movement, radiological outcomes and complications were pooled to produce aggregate means and standard deviation. A total of 310 titles and abstracts were identified. Fourteen papers remained for analysis. Total patient number was 357, mean age 63.72 years and mean follow-up 12.77 months. Mean functional scores were all rated as 'excellent'. Aggregate means: flexion 53.62°, extension 56.38°, pronation 69.10°, supination 70.29°, ulnar deviation 28.35°, radial deviation 18.12°, radial height 8.98 mm, radial inclination 16.51°, volar tilt 5.35°, ulnar variance 0.66 mm and grip strength 90.37 %. Overall complication rate was 19.6 %. Tendon rupture was unreported. Tendon irritation was 0.88 %. Radial nerve paraesthesia was 11.44 %. Fixed angle IM devices facilitate excellent functional outcomes, with radiological and clinical parameters at least equivalent to volar plate devices. Low rates of tendon irritation and absence of tendon rupture are advantageous. Significant limitations include a lack of application for complex articular injuries and the propensity to cause a transient neuritis of the superficial branch of the radial nerve.

  19. Supplemental vibrational force does not reduce pain experience during initial alignment with fixed orthodontic appliances: a multicenter randomized clinical trial

    PubMed Central

    Woodhouse, Neil R.; DiBiase, Andrew T.; Papageorgiou, Spyridon N.; Johnson, Nicola; Slipper, Carmel; Grant, James; Alsaleh, Maryam; Cobourne, Martyn T.

    2015-01-01

    This prospective randomized trial investigated the effect of supplemental vibrational force on orthodontic pain during alignment with fixed-appliances. Eighty-one subjects < 20 years-old undergoing extraction-based fixed-appliance treatment were randomly allocated to supplementary (20-minutes/day) use of an intra-oral vibrational device (AcceleDent®) (n = 29); an identical non-functional (sham) device (n = 25) or fixed-appliances only (n = 27). Each subject recorded pain intensity (using a 100-mm visual-analogue scale) and intake of oral analgesia in a questionnaire, following appliance-placement (T1) and first-adjustment (T2) for 1-week (immediately-after, 4, 24, 72-hours and at 1-week). Mean maximum-pain for the total sample was 72.96 mm [SD 21.59; 95%CI 68.19–77.74 mm] with no significant differences among groups (P = 0.282). Subjects taking analgesics reported slightly higher maximum-pain although this was not significant (P = 0.170). The effect of intervention was independent of analgesia (P = 0.883). At T1 and T2, a statistically and clinically significant increase in mean pain was seen at 4 and 24-hours, declining at 72-hours and becoming insignificant at 1-week. For mean alignment-rate, pain-intensity and use of analgesics, no significant differences existed between groups (P > 0.003). The only significant predictor for mean pain was time. Use of an AcceleDent vibrational device had no significant effect on orthodontic pain or analgesia consumption during initial alignment with fixed appliances. PMID:26610843

  20. Non-pyogenic infections of the spine.

    PubMed

    Skaf, Ghassan S; Kanafani, Zeina A; Araj, George F; Kanj, Souha S

    2010-08-01

    Subacute and chronic spondylodiscitis can be caused by a wide spectrum of infectious aetiologies including Mycobacterium tuberculosis, Brucella spp. and a variety of fungi including Aspergillus spp., Candida spp. and Cryptococcus neoformans. Knowledge of the local epidemiology and prior exposure might suggest the aetiology. Non-invasive diagnostic approaches, such as blood culture or antibody titres in the case of Brucella or antigen detection in the case of fungal infections, can be helpful in reaching the diagnosis. However, direct aspiration or tissue biopsy is usually necessary to identify the causative organism. Specimens are usually sent for pathology, special stains, cultures and, when indicated, molecular analysis. To minimise morbidity and mortality, antibiotic treatment should be initiated promptly directed against the suspected organism, and later adjusted according to the confirmed aetiology. Surgical treatment is reserved for recurrent infection, unstable spinal segment or marked kyphosis in the face of any neurological deficits and uncontrollable pain. Surgical approaches are dictated by the anatomic location of the offending lesion. Once medical treatment fails and surgery becomes warranted, we advocate the use of a two-stage surgical treatment for non-fixed kyphosis and a three-stage operation for fixed kyphosis. Copyright (c) 2010 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  1. Live Imaging of Meiosis I in Late-Stage Drosophila melanogaster Oocytes.

    PubMed

    Hughes, Stacie E; Hawley, R Scott

    2017-01-01

    Drosophila melanogaster has been studied for a century as a genetic model to understand recombination, chromosome segregation, and the basic rules of inheritance. However, it has only been about 25 years since the events that occur during nuclear envelope breakdown, spindle assembly, and chromosome orientation during D. melanogaster female meiosis I were first visualized by fixed cytological methods (Theurkauf and Hawley, J Cell Biol 116:1167-1180, 1992). Although these fixed cytological studies revealed many important details about the events that occur during meiosis I, they failed to elucidate the timing or order of these events. The development of protocols for live imaging of meiotic events within the oocyte has enabled collection of real-time information on the kinetics and dynamics of spindle assembly, as well as the behavior of chromosomes during prometaphase I. Here, we describe a method to visualize spindle assembly and chromosome movement during meiosis I by injecting fluorescent dyes to label microtubules and DNA into stage 12-14 oocytes. This method enables the events during Drosophila female meiosis I, such as spindle assembly and chromosome movement, to be observed in vivo, regardless of genetic background, with exceptional spatial and temporal resolution.

  2. Basin stability measure of different steady states in coupled oscillators

    NASA Astrophysics Data System (ADS)

    Rakshit, Sarbendu; Bera, Bidesh K.; Majhi, Soumen; Hens, Chittaranjan; Ghosh, Dibakar

    2017-04-01

    In this report, we investigate the stabilization of saddle fixed points in coupled oscillators where individual oscillators exhibit the saddle fixed points. The coupled oscillators may have two structurally different types of suppressed states, namely amplitude death and oscillation death. The stabilization of saddle equilibrium point refers to the amplitude death state where oscillations are ceased and all the oscillators converge to the single stable steady state via inverse pitchfork bifurcation. Due to multistability features of oscillation death states, linear stability theory fails to analyze the stability of such states analytically, so we quantify all the states by basin stability measurement which is an universal nonlocal nonlinear concept and it interplays with the volume of basins of attractions. We also observe multi-clustered oscillation death states in a random network and measure them using basin stability framework. To explore such phenomena we choose a network of coupled Duffing-Holmes and Lorenz oscillators which are interacting through mean-field coupling. We investigate how basin stability for different steady states depends on mean-field density and coupling strength. We also analytically derive stability conditions for different steady states and confirm by rigorous bifurcation analysis.

  3. Unexpected timely fracture union in matrix metalloproteinase 9 deficient mice.

    PubMed

    Yuasa, Masato; Saito, Masanori; Molina, Cesar; Moore-Lotridge, Stephanie N; Benvenuti, Michael A; Mignemi, Nicholas A; Okawa, Atsushi; Yoshii, Toshitaka; Schwartz, Herbert S; Nyman, Jeffry S; Schoenecker, Jonathan G

    2018-01-01

    Immediately following a fracture, a fibrin laden hematoma is formed to prevent bleeding and infection. Subsequently, the organized removal of fibrin, via the protease plasmin, is essential to permit fracture repair through angiogenesis and ossification. Yet, when plasmin activity is lost, the depletion of fibrin alone is insufficient to fully restore fracture repair, suggesting the existence of additional plasmin targets important for fracture repair. Previously, activated matrix metalloproteinase 9 (MMP-9) was demonstrated to function in fracture repair by promoting angiogenesis. Given that MMP-9 is a defined plasmin target, it was hypothesized that pro-MMP-9, following plasmin activation, promotes fracture repair. This hypothesis was tested in a fixed murine femur fracture model with serial assessment of fracture healing. Contrary to previous findings, a complete loss of MMP-9 failed to affect fracture healing and union through 28 days post injury. Therefore, these results demonstrated that MMP-9 is dispensable for timely fracture union and cartilage transition to bone in fixed femur fractures. Pro-MMP-9 is therefore not a significant target of plasmin in fracture repair and future studies assessing additional plasmin targets associated with angiogenesis are warranted.

  4. Adequacy of Fixed-Dose Heparin Infusions for Venous Thromboembolism Prevention after Microsurgical Procedures.

    PubMed

    Bertolaccini, Corinne M; Prazak, Ann Marie B; Agarwal, Jayant; Goodwin, Isak A; Rockwell, W Bradford; Pannucci, Christopher J

    2018-05-22

     In microvascular surgery, patients often receive unfractionated heparin infusions to minimize risk for microvascular thrombosis. Patients who receive intravenous (IV) heparin are believed to have adequate prophylaxis against venous thromboembolism (VTE). Whether a fixed dose of IV heparin provides detectable levels of anticoagulation, or whether the "one size fits all" approach provides adequate prophylaxis against VTE remains unknown. This study examined the pharmacodynamics of fixed-dose heparin infusions and the effects of real-time, anti-factor Xa (aFXa) level driven heparin dose adjustments.  This prospective clinical trial recruited adult microvascular surgery patients placed on a fixed-dose (500 units/h) unfractionated heparin infusion during their initial microsurgical procedure. Steady-state aFXa levels, a marker of unfractionated heparin efficacy and safety, were monitored. Patients with out-of-range aFXa levels received protocol-driven real-time dose adjustments. Outcomes of interest included aFXa levels in response to heparin 500 units/h, number of dose adjustments required to achieve goal aFXa levels, time to reach goal aFXa level, and 90-day clinically relevant bleeding and VTE.  Twenty patients were recruited prospectively. None of 20 patients had any detectable level of anticoagulation in response to heparin infusions at 500 units/h. The median number of dose adjustments required to reach goal level was five, and median weight-based dose to reach goal level was 11.8 units/kg/h. Real-time dose adjustments significantly increased the proportion of patients with in-range levels (60 vs. 0%, p  = 0.0001). The 90-day VTE rate was 5% and 90-day clinically relevant bleeding rate was 5%.  Fixed-dose heparin infusions at a rate of 500 units/h do not provide a detectable level of anticoagulation after microsurgical procedures and are insufficient for the majority of patients who require VTE prophylaxis. Weight-based heparin infusions at 10 to 12 units/kg/h deserve future study in patients undergoing microsurgical procedures to increase the proportion of patients receiving adequate VTE prophylaxis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Exploring the relation between people’s theories of intelligence and beliefs about brain development

    PubMed Central

    Thomas, Ashley J.; Sarnecka, Barbara W.

    2015-01-01

    A person’s belief about whether intelligence can change (called their implicit theory of intelligence) predicts something about that person’s thinking and behavior. People who believe intelligence is fixed (called entity theorists) attribute failure to traits (i.e., “I failed the test because I’m not smart.”) and tend to be less motivated in school; those who believe intelligence is malleable (called incremental theorists) tend to attribute failure to behavior (i.e., “I failed the test because I didn’t study.”) and are more motivated in school. In previous studies, researchers have characterized participants as either entity or incremental theorists based on their agreement or disagreement with three statements. The present study further explored the theories-of-intelligence (TOI) construct in two ways: first, we asked whether these theories are coherent, in the sense that they show up not only in participants’ responses to the three standard assessment items, but on a broad range of questions about intelligence and the brain. Second, we asked whether these theories are discrete or continuous. In other words, we asked whether people believe one thing or the other (i.e., that intelligence is malleable or fixed), or if there is a continuous range of beliefs (i.e., people believe in malleability to a greater or lesser degree). Study (1) asked participants a range of general questions about the malleability of intelligence and the brain. Study (2) asked participants more specific questions about the brains of a pair of identical twins who were separated at birth. Results showed that TOI are coherent: participants’ responses to the three standard survey items are correlated with their responses to questions about the brain. But the theories are not discrete: although responses to the three standard survey items fell into a bimodal distribution, responses to the broader range of questions fell into a normal distribution suggesting the theories are continuous. PMID:26191027

  6. Pacer Comet 4: Automated Jet Engine Testing of a TF33-P100 Pratt & Whitney Engine

    NASA Astrophysics Data System (ADS)

    Mason, Rex Bolding

    Pacer Comet 4 found its life out of necessity to replace an obsolescent Pacer Comet 3 engine test system at Tinker AFB in Oklahoma City, OK. Pacer Comet 3 (PC3) was created and installed in the early 1980's to test jet engines from a wide range of planes. PC3 had several problems from a maintenance standpoint: contractors designed and installed the system but the contract did not include the OEM data package. Without drawings or design knowledge, fixing the smallest of problems could turn into a multi-day project. In addition to high cost, as the OEM companies of proprietary parts went out of business, it became impossible to find a replacement for a failed part. These issues set the framework for the Pacer Comet 4 (PC4) system. PC4 was created as an organic AF and Department of Defense collaboration to fix the issues with PC3. PC4 provides the customer with a complete data package including multiple drawing sets and data sheets for all parts used, as well as design files for all PCBs created in house. PC4 has a standard to use commercially available off the shelf parts (COTS). The reason for this is sustainability in maintenance. If a part is to fail, it should be able to be purchased from any manufacturer that meets the specs of the original product. No proprietary parts are used, except as directed by the engine's OEM. This thesis will focus on the design and installation of the on-frame data acquisition PC4 system for the Pratt & Whitney TF33-P100A-QEC engine that is currently in use on the E3 Sentry. This thesis will show efficiency improvements for maintenance sustainability (70% cabling reduction) as well as discuss performance improvements in both test and production environments.

  7. Examining the postural awareness and flexibility changes in physical therapy students who took clinical Pilates class.

    PubMed

    Atilgan, Esra; Tarakci, Devrim; Mutluay, Fatma

    2017-01-01

    This study aimed to evaluate postural awareness and changes in posture and flexibility of students who took Clinical Pilates class as an elective course at the undergraduate level. The study conducted from 2013-2016 included 98 students who took Clinical Pilates class at the Department of Physical Therapy and Rehabilitation, School of Health Sciences, Istanbul Medipol University, Turkey. The flexibility levels of the study participants were measured before and after the Clinical Pilates education using finger-to-floor test and modified Schober's test. Observational posture analysis and postural awareness were recorded using the scale prepared by the researchers. The post-education evaluations showed that postural distortions were fixed, and a significant increase in the postural awareness of the students was observed compared with the pre-education period. The results of both modified Schober's test and finger-to-floor test, which were used to measure the flexibility levels, showed a statistically significant increase in post-education scores compared with those of the pre-education period. This study showed that the Clinical Pilates course increased postural awareness and flexibility of physical therapy students and fixed postural distortions. Thus, the inclusion of Clinical Pilates class in the undergraduate education is considered to be important.

  8. Examining the postural awareness and flexibility changes in physical therapy students who took clinical Pilates class

    PubMed Central

    Atilgan, Esra; Tarakci, Devrim; Mutluay, Fatma

    2017-01-01

    Objective: This study aimed to evaluate postural awareness and changes in posture and flexibility of students who took Clinical Pilates class as an elective course at the undergraduate level. Methods: The study conducted from 2013-2016 included 98 students who took Clinical Pilates class at the Department of Physical Therapy and Rehabilitation, School of Health Sciences, Istanbul Medipol University, Turkey. The flexibility levels of the study participants were measured before and after the Clinical Pilates education using finger-to-floor test and modified Schober’s test. Observational posture analysis and postural awareness were recorded using the scale prepared by the researchers. Results: The post-education evaluations showed that postural distortions were fixed, and a significant increase in the postural awareness of the students was observed compared with the pre-education period. The results of both modified Schober’s test and finger-to-floor test, which were used to measure the flexibility levels, showed a statistically significant increase in post-education scores compared with those of the pre-education period. Conclusion: This study showed that the Clinical Pilates course increased postural awareness and flexibility of physical therapy students and fixed postural distortions. Thus, the inclusion of Clinical Pilates class in the undergraduate education is considered to be important. PMID:28811786

  9. Long-Term Stability of Membership in a Wechsler Intelligence Scale for Children--Third Edition (WISC-III) Subtest Core Profile Taxonomy

    ERIC Educational Resources Information Center

    Borsuk, Ellen R.; Watkins, Marley W.; Canivez, Gary L.

    2006-01-01

    Although often applied in practice, clinically based cognitive subtest profile analysis has failed to achieve empirical support. Nonlinear multivariate subtest profile analysis may have benefits over clinically based techniques, but the psychometric properties of these methods must be studied prior to their implementation and interpretation. The…

  10. Panning for Gold: A Clinician's Guide to Using Research

    ERIC Educational Resources Information Center

    Williams, Lee M.; Patterson, Jo Ellen; Miller, Richard B.

    2006-01-01

    The gap between research and clinical practice is one of the key challenges facing family therapy. Clinicians often fail to incorporate research findings into their practice because they do not know how to search, evaluate, or apply research to their clinical work. The purpose of this article is to help clinicians become better consumers of…

  11. Training Non-Clinical Community Psychologists at the Master's Level: A Case Study of Outcomes.

    ERIC Educational Resources Information Center

    Hoffnung, Robert J.; And Others

    Previous research on training for community psychology has failed to distinguish between the effects of different types of training programs or to address the viability of master's level training in community psychology. To explore the value of master's level training in non-clinical community psychology, 83 of 112 students who earned master's…

  12. An International Basic Science and Clinical Research Summer Program for Medical Students

    ERIC Educational Resources Information Center

    Ramjiawan, Bram; Pierce, Grant N.; Anindo, Mohammad Iffat Kabir; AlKukhun, Abedalrazaq; Alshammari, Abdullah; Chamsi, Ahmad Talal; Abousaleh, Mohannad; Alkhani, Anas; Ganguly, Pallab K.

    2012-01-01

    An important part of training the next generation of physicians is ensuring that they are exposed to the integral role that research plays in improving medical treatment. However, medical students often do not have sufficient time to be trained to carry out any projects in biomedical and clinical research. Many medical students also fail to…

  13. Commercial Insurance vs Community-Based Health Plans: Time for a Policy Option With Clinical Emphasis to Address the Cost Spiral

    ERIC Educational Resources Information Center

    Amundson, Bruce

    2005-01-01

    The nation continues its ceaseless struggle with the spiraling cost of health care. Previous efforts (regulation, competition, voluntary action) have included almost every strategy except clinical. Insurers have largely failed in their cost-containment efforts. There is a strong emerging body of literature that demonstrates the relationship…

  14. Implant-supported fixed restoration of post-traumatic mandibular defect accompanied with skin grafting: A clinical report

    PubMed Central

    Noh, Kwantae; Choi, Woo-Jin

    2013-01-01

    Traumatic defects are mostly accompanied by hard and soft tissue loss. This report describes the surgical and prosthetic treatment of a patient with post-traumatic mandibular defect. A split-thickness skin graft was performed prior to implant placement and prefabricated acrylic stent was placed to hold the graft in place. The esthetic and functional demands of the patient were fulfilled by implant-supported screw-retained fixed prosthesis using CAD-CAM technology. PMID:23508120

  15. Kidney Disease Basics

    MedlinePlus

    ... My Kidneys Fail? Clinical Trials What Is Chronic Kidney Disease? Chronic kidney disease (CKD) means your kidneys ... work, be active, and enjoy life. Will my kidneys get better? Kidney disease is often “progressive”, which ...

  16. Midterm outcomes of the Zenith Renu AAA Ancillary Graft.

    PubMed

    Jim, Jeffrey; Rubin, Brian G; Geraghty, Patrick J; Money, Samuel R; Sanchez, Luis A

    2011-08-01

    The Zenith Renu abdominal aortic aneurysm (AAA) Ancillary Graft (Cook Medical Inc, Bloomington, Ind) provides active proximal fixation for treatment of pre-existing endografts with failed or failing proximal fixation or seal. The purpose of this study was to evaluate the midterm outcomes of treatment with this device. From September 2005 to November 2006, a prospective, nonrandomized, multicenter, postmarket registry was utilized to collect physician experiences from 151 cases (89 converters and 62 main body extensions) at 95 institutions. Preoperative indications and procedural and postimplantation outcomes were collected and analyzed. Technical success and clinical success were determined as defined by the Society of Vascular Surgery reporting standards. Patients were predominantly male (87%) with a mean age of 77 years. The interval between the original endograft implantation to Renu treatment was 43.4 ± 18.7 months. The indications for treatment were endoleak (n = 111), migration (n = 136), or both (n = 94). Technical success was 98.0% with two cases of intraoperative conversion and one case of persistent type IA endoleak. The median follow-up for the cohort was 45.0 months (range, 0-56 months; interquartile range, 25.0 months). Overall, 32 cases had treatment failures that included at least one of the following: death (n = 5), type I/III endoleak (n = 18), graft infection (n = 1), thrombosis (n = 1), aneurysm enlargement >5 mm (n = 9), rupture (n = 4), conversion (n = 9, with 7 after 30 days), and migration (n = 1). Overall, the clinical success for the entire cohort during the follow-up period was 78.8% (119/151). The postmarket registry data confirm that the Zenith Renu AAA Ancillary Graft can be used to treat endovascular repairs that failed due to proximal attachment failures. The salvage treatment with the Renu device had high technical success rate and resulted in clinical success in a majority of patients (78.8%). While failed endovascular repairs can be salvaged, a clinical failure in one of five patients still emphasizes the importance of patient and device selection during initial endovascular aneurysm repair to ensure durable success. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  17. The failure to fail underperforming trainees in health professions education: A BEME systematic review: BEME Guide No. 42.

    PubMed

    Yepes-Rios, Monica; Dudek, Nancy; Duboyce, Rita; Curtis, Jerri; Allard, Rhonda J; Varpio, Lara

    2016-11-01

    Many clinical educators feel unprepared and/or unwilling to report unsatisfactory trainee performance. This systematic review consolidates knowledge from medical, nursing, and dental literature on the experiences and perceptions of evaluators or assessors with this failure to fail phenomenon. We searched the English language literature in CINAHL, EMBASE, and MEDLINE from January 2005 to January 2015. Qualitative and quantitative studies were included. Following our review protocol, registered with BEME, reviewers worked in pairs to identify relevant articles. The investigators participated in thematic analysis of the qualitative data reported in these studies. Through several cycles of analysis, discussion and reflection, the team identified the barriers and enablers to failing a trainee. From 5330 articles, we included 28 publications in the review. The barriers identified were (1) assessor's professional considerations, (2) assessor's personal considerations, (3) trainee related considerations, (4) unsatisfactory evaluator development and evaluation tools, (5) institutional culture and (6) consideration of available remediation for the trainee. The enablers identified were: (1) duty to patients, to society, and to the profession, (2) institutional support such as backing a failing evaluation, support from colleagues, evaluator development, and strong assessment systems, and (3) opportunities for students after failing. The inhibiting and enabling factors to failing an underperforming trainee were common across the professions included in this study, across the 10 years of data, and across the educational continuum. We suggest that these results can inform efforts aimed at addressing the failure to fail problem.

  18. Coronary tortuosity: a long and winding road

    PubMed Central

    Zegers, E.S.; Meursing, B.T.J.; Zegers, E.B.; Oude Ophuis, A.J.M.

    2007-01-01

    Coronary tortuosity is a phenomenon often encountered by cardiologists performing coronary angiography. The aetiology and clinical importance of coronary tortuosity are still unclear. Coronary tortuosity without fixed atherosclerotic stenosis in patients with angina pectoris and an abnormal exercise stress test has never been described in the literature. This article describes three cases of patients with anginal complaints, an abnormal exercise stress test and coronary angiography without the presence of a fixed atherosclerotic lesion. It is hypothesised that coronary tortuosity leads to flow alteration resulting in a reduction in coronary pressure distal to the tortuous segment of the coronary artery, subsequently leading to ischaemia. Future studies will be necessary to elucidate the actual mechanism of coronary tortuosity and its clinical significance. (Neth Heart J 2007;15:191-5.17612682) PMID:17612682

  19. [Fatigue damage analysis of porcelain in all-ceramic crowns].

    PubMed

    Liu, Yi-hong; Feng, Hai-lan; Liu, Guang-hua; Shen, Zhi-jian

    2010-02-18

    To investigate the fatigue damage mechanism of porcelain, and its relation with the microscopic defects in clinically failed all-ceramic crowns. Collecting the bilayered all-ceramic crowns failed in vivo. The fractured surfaces and occlusial surfaces of failed crowns were examined by an optical microscope followed by detailed fractography investigations using a field emission scanning electron microscope. When chemical impurities were of concern, energy-dispersive X-ray spectroscopy analysis was performed to examine chemical composition. A standard practice for fractography failure analysis of advanced ceramics is applied to disclose the fracture mode, and damage character. Three types of fracture features are defined as breakdown of the entire crown, and porcelain chipping-off/delamination. Alumina crowns were usually characterized by breakdown of the entire crown, while zirconia crowns by porcelain chipping-off and delamination. The fatigue damage of porcelain was classified into surface wear, cone crack, and porcelain delamination. The observed microscopic defects in this study included air bubbles and impurity particles. The multi-point occlusial contacts were recommended in all-ceramic restorations clinically. The thickness of porcelain is important for the anti-fatigue ability of porcelain. Cautions have to be taken to avoid contaminations during the veneering processes.

  20. Urgent Bypass Surgery Following Failed Endovascular Treatment in Acute Symptomatic Stroke Patient With MCA Occlusion.

    PubMed

    Lee, Chang Yeob; Kim, Chang Hyun; Lee, Chang-Young; Sohn, Sung-Il; Hong, Jeong-Ho

    2017-01-01

    Although the benefits of extracranial-intracranial bypass surgery remain controversial, there is some surgical rationale for the augmentation of cerebral blood flow in cases of acute ischemic stroke with hemodynamic instability. We report a case of a 62-year-old woman who suddenly developed right hemiplegia and global aphasia. Initial magnetic resonance imaging and magnetic resonance angiography revealed a small acute ischemic lesion in left parietal lobe with occlusion at the left middle cerebral artery. We performed an endovascular thrombectomy, which failed. Her neurological deficits remained unchanged. On the basis of immediate postendovascular magnetic resonance perfusion, diffusion-weighted imaging (DWI), and neurological examination, an obvious clinical-DWI and a DWI-perfusion-weighted imaging mismatch were detected. We decided to perform emergency superficial temporal artery to middle cerebral artery bypass to prevent further progression of cerebral ischemia. On a 3-month follow-up, neurological deficits remained minimal motor aphasia and dysarthria. Following failed endovascular treatment in patients with acute symptoms attributed to major cerebral artery occlusion, we recommend immediate multimodal neuroimaging. If there are clinical-DWI and DWI-perfusion-weighted imaging mismatch indications, surgical revascularization could be considered as the next salvageable strategy.

  1. Failure analysis of ceramic clinical cases using qualitative fractography.

    PubMed

    Scherrer, Susanne S; Quinn, Janet B; Quinn, George D; Kelly, J Robert

    2006-01-01

    To educate dental academic staff and clinicians on the application of descriptive (qualitative) fractography for analyses of clinical and laboratory failures of brittle materials such as glass and ceramic. The fracture surface topography of failed glass, glass fiber-reinforced composite, and ceramic restorations (Procera, Cerestore, In-Ceram, porcelain-fused-to-metal) was examined utilizing a scanning electron microscope. Replicas and original failed parts were scrutinized for classic fractographic features such as hackle, wake hackle, twist hackle, arrest lines, and mirrors. Failed surfaces of the veneering porcelain of ceramic and porcelain-fused-to-metal crowns exhibited hackle, wake hackle, twist hackle, arrest lines, and compression curl, which were produced by the interaction of the advancing crack with the microstructure of the material. Fracture surfaces of glass and glass fiber-reinforced composite showed additional features, such as velocity hackle and mirrors. The observed features were good indicators of the local direction of crack propagation and were used to trace the crack back to an initial starting area (the origin). Examples of failure analysis in this study are intended to guide the researcher in using qualitative (descriptive) fractography as a tool for understanding the failure process in brittle restorative materials and also for assessing possible design inadequacies.

  2. Balloon catheter dilation and nasolacrimal duct intubation for treatment of nasolacrimal duct obstruction after failed probing.

    PubMed

    Repka, Michael X; Chandler, Danielle L; Holmes, Jonathan M; Hoover, Darren L; Morse, Christine L; Schloff, Susan; Silbert, David I; Tien, D Robbins

    2009-05-01

    To compare the outcomes of balloon catheter dilation and nasolacrimal intubation as treatment for congenital nasolacrimal duct obstruction after failed probing in children younger than 4 years. We conducted a prospective, nonrandomized, multicenter study that enrolled 159 children aged 6 months to younger than 48 months who had a history of a single failed nasolacrimal duct probing and at least 1 of the following clinical signs of nasolacrimal duct obstruction: epiphora, mucous discharge, or increased tear lake. One hundred ninety-nine eyes underwent either balloon catheter nasolacrimal duct dilation or nasolacrimal duct intubation. Treatment success was defined as absence of epiphora, mucous discharge, or increased tear lake at the outcome visit 6 months after surgery. Treatment success was reported in 65 of 84 eyes (77%; 95% confidence interval, 65%-85%) in the balloon catheter dilation group compared with 72 of 88 eyes (84% after adjustment for intereye correlation; 74%-91%) in the nasolacrimal intubation group (risk ratio for success for intubation vs balloon dilation, 1.08; 0.95-1.22). Both balloon catheter dilation and nasolacrimal duct intubation alleviate the clinical signs of persistent nasolacrimal duct obstruction in a similar percentage of patients.

  3. A Fixed-Lag Kalman Smoother to Filter Power Line Interference in Electrocardiogram Recordings.

    PubMed

    Warmerdam, G J J; Vullings, R; Schmitt, L; Van Laar, J O E H; Bergmans, J W M

    2017-08-01

    Filtering power line interference (PLI) from electrocardiogram (ECG) recordings can lead to significant distortions of the ECG and mask clinically relevant features in ECG waveform morphology. The objective of this study is to filter PLI from ECG recordings with minimal distortion of the ECG waveform. In this paper, we propose a fixed-lag Kalman smoother with adaptive noise estimation. The performance of this Kalman smoother in filtering PLI is compared to that of a fixed-bandwidth notch filter and several adaptive PLI filters that have been proposed in the literature. To evaluate the performance, we corrupted clean neonatal ECG recordings with various simulated PLI. Furthermore, examples are shown of filtering real PLI from an adult and a fetal ECG recording. The fixed-lag Kalman smoother outperforms other PLI filters in terms of step response settling time (improvements that range from 0.1 to 1 s) and signal-to-noise ratio (improvements that range from 17 to 23 dB). Our fixed-lag Kalman smoother can be used for semi real-time applications with a limited delay of 0.4 s. The fixed-lag Kalman smoother presented in this study outperforms other methods for filtering PLI and leads to minimal distortion of the ECG waveform.

  4. Comparison of biomechanical function at ideal and varied surgical placement for two lumbar artificial disc implant designs: mobile-core versus fixed-core.

    PubMed

    Moumene, Missoum; Geisler, Fred H

    2007-08-01

    Finite element model. To estimate the effect of lumbar mobile-core and fixed-core artificial disc design and placement on the loading of the facet joints, and stresses on the polyethylene core. Although both mobile-core and fixed-core lumbar artificial disc designs have been used clinically, the effect of their design and the effect of placement within the disc space on the structural element loading, and in particular the facets and the implant itself, have not been investigated. A 3D nonlinear finite element model of an intact ligamentous L4-L5 motion segment was developed and validated in all 6 df based on previous experiments conducted on human cadavers. Facet loading of a mobile-core TDR and a fixed-core TDR were estimated with 4 different prosthesis placements for 3 different ranges of motion. Placing the mobile-core TDR anywhere within the disc space reduced facet loading by more than 50%, while the fixed-core TDR increased facet loading by more than 10% when compared with the intact disc in axial rotation. For central (ideal) placement, the mobile- and fixed-core implants were subjected to compressive stresses on the order of 3 MPa and 24 MPa, respectively. The mobile-core stresses were not affected by implant placement, while the fixed-core stresses increased by up to 40%. A mobile-core artificial disc design is less sensitive to placement, and unloads the facet joints, compared with a fixed-core design. The decreased core stress may result in a reduced potential for wear in a mobile-core prosthesis compared with a fixed-core prosthesis, which may increase the functional longevity of the device.

  5. Feeding behaviour in young children who fail to thrive.

    PubMed

    Drewett, Robert F; Kasese-Hara, Mambwe; Wright, Charlotte

    2003-02-01

    One-year-old children who failed to thrive in infancy were identified through a specialist clinical service using a conditional weight gain criterion which identified the slowest gaining 5%. Control children of the same age and sex were recruited from the same local geographical area and had the same primary care physician. The food intake and feeding behaviour of the groups was compared using a detailed observational micro-analysis of a lunchtime meal, using a behavioural coding scheme developed for use over the weaning period. Both food and fluid intake at the test meal were significantly lower in the children who failed to thrive than the controls. There was no significant difference in the energy density of the foods they consumed. As recorded in the behaviour counts at the meal, the mothers of the children who failed to thrive fed them as much as or more than the control mothers fed their children. The children who failed to thrive tended to refuse or reject the offered food more, and also fed themselves significantly less often than the controls. These behavioural differences during the meal accounted for about one third of the difference in energy intake between the groups.

  6. Why fish oil fails: a comprehensive 21st century lipids-based physiologic analysis.

    PubMed

    Peskin, B S

    2014-01-01

    The medical community suffered three significant fish oil failures/setbacks in 2013. Claims that fish oil's EPA/DHA would stop the progression of heart disease were crushed when The Risk and Prevention Study Collaborative Group (Italy) released a conclusive negative finding regarding fish oil for those patients with high risk factors but no previous myocardial infarction. Fish oil failed in all measures of CVD prevention-both primary and secondary. Another major 2013 setback occurred when fish oil's DHA was shown to significantly increase prostate cancer in men, in particular, high-grade prostate cancer, in the Selenium and Vitamin E Cancer Prevention Trial (SELECT) analysis by Brasky et al. Another monumental failure occurred in 2013 whereby fish oil's EPA/DHA failed to improve macular degeneration. In 2010, fish oil's EPA/DHA failed to help Alzheimer's victims, even those with low DHA levels. These are by no means isolated failures. The promise of fish oil and its so-called active ingredients EPA / DHA fails time and time again in clinical trials. This lipids-based physiologic review will explain precisely why there should have never been expectation for success. This review will focus on underpublicized lipid science with a focus on physiology.

  7. Why Fish Oil Fails: A Comprehensive 21st Century Lipids-Based Physiologic Analysis

    PubMed Central

    Peskin, B. S.

    2014-01-01

    The medical community suffered three significant fish oil failures/setbacks in 2013. Claims that fish oil's EPA/DHA would stop the progression of heart disease were crushed when The Risk and Prevention Study Collaborative Group (Italy) released a conclusive negative finding regarding fish oil for those patients with high risk factors but no previous myocardial infarction. Fish oil failed in all measures of CVD prevention—both primary and secondary. Another major 2013 setback occurred when fish oil's DHA was shown to significantly increase prostate cancer in men, in particular, high-grade prostate cancer, in the Selenium and Vitamin E Cancer Prevention Trial (SELECT) analysis by Brasky et al. Another monumental failure occurred in 2013 whereby fish oil's EPA/DHA failed to improve macular degeneration. In 2010, fish oil's EPA/DHA failed to help Alzheimer's victims, even those with low DHA levels. These are by no means isolated failures. The promise of fish oil and its so-called active ingredients EPA / DHA fails time and time again in clinical trials. This lipids-based physiologic review will explain precisely why there should have never been expectation for success. This review will focus on underpublicized lipid science with a focus on physiology. PMID:24551453

  8. Compliance, Safety, and Effectiveness of Fixed-Dose Artesunate-Amodiaquine for Presumptive Treatment of Non-Severe Malaria in the Context of Home Management of Malaria in Madagascar

    PubMed Central

    Ratsimbasoa, Arsène; Ravony, Harintsoa; Vonimpaisomihanta, Jeanne-Aimée; Raherinjafy, Rogelin; Jahevitra, Martial; Rapelanoro, Rabenja; Rakotomanga, Jean De Dieu Marie; Malvy, Denis; Millet, Pascal; Ménard, Didier

    2012-01-01

    Home management of malaria is recommended for prompt, effective antimalarial treatment in children less than five years of age. Compliance, safety, and effectiveness of the new fixed-dose artesunate-amodiaquine regimen used to treat suspected malaria were assessed in febrile children enrolled in a 24-month cohort study in two settings in Madagascar. Children with fever were asked to visit community health workers. Presumptive antimalarial treatment was given and further visits were scheduled for follow-up. The primary endpoint was the risk of clinical/parasitologic treatment failure. Secondary outcomes included fever/parasite clearance, change in hemoglobin levels, and frequency of adverse events. The global clinical cure rate was 98.4% by day 28 and 97.9% by day 42. Reported compliance was 83.4%. No severe adverse effects were observed. This study provides comprehensive data concerning the clinical cure rate obtained with artesunate-amodiaquine and evidence supporting the scaling up of home management of malaria. PMID:22302849

  9. MethylMeter(®): bisulfite-free quantitative and sensitive DNA methylation profiling and mutation detection in FFPE samples.

    PubMed

    McCarthy, David; Pulverer, Walter; Weinhaeusel, Andreas; Diago, Oscar R; Hogan, Daniel J; Ostertag, Derek; Hanna, Michelle M

    2016-06-01

    Development of a sensitive method for DNA methylation profiling and associated mutation detection in clinical samples. Formalin-fixed and paraffin-embedded tumors received by clinical laboratories often contain insufficient DNA for analysis with bisulfite or methylation sensitive restriction enzymes-based methods. To increase sensitivity, methyl-CpG DNA capture and Coupled Abscription PCR Signaling detection were combined in a new assay, MethylMeter(®). Gliomas were analyzed for MGMT methylation, glioma CpG island methylator phenotype and IDH1 R132H. MethylMeter had 100% assay success rate measuring all five biomarkers in formalin-fixed and paraffin-embedded tissue. MGMT methylation results were supported by survival and mRNA expression data. MethylMeter is a sensitive and quantitative method for multitarget DNA methylation profiling and associated mutation detection. The MethylMeter-based GliomaSTRAT assay measures methylation of four targets and one mutation to simultaneously grade gliomas and predict their response to temozolomide. This information is clinically valuable in management of gliomas.

  10. Clinical insomnia and associated factors in failed back surgery syndrome: a retrospective cross-sectional study.

    PubMed

    Yun, Soon Young; Kim, Do Heon; Do, Hae Yoon; Kim, Shin Hyung

    2017-01-01

    Background Insomnia frequently occurs to patients with persistent back pain. By worsening pain, mood, and physical functioning, insomnia could lead to the negative clinical consequences of patients with failed back surgery syndrome (FBSS). This retrospective and cross-sectional study aims to identify the risk factors associated with clinical insomnia in FBSS patients. Methods A total of 194 patients with FBSS, who met the study inclusion criteria, were included in this analysis. The Insomnia Severity Index (ISI) was utilized to ascertain the presence of clinical insomnia (ISI score ≥ 15). Logistic regression analysis evaluates patient demographic factors, clinical factors including prior surgical factors, and psychological factors to identify the risk factors of clinical insomnia in FBSS patients. Results After the persistent pain following lumbar spine surgery worsened, 63.4% of patients reported a change from mild to severe insomnia. In addition, 26.2% of patients met the criteria for clinically significant insomnia. In a multivariate logistic regression analysis, high pain intensity (odds ratio (OR) =2.742, 95% confidence interval (CI): 1.022 - 7.353, P =0.045), high pain catastrophizing (OR=4.185, 95% CI: 1.697 - 10.324, P =0.002), greater level of depression (OR =3.330, 95% CI: 1.127 - 9.837, P =0.030) were significantly associated with clinical insomnia. However, patient demographic factors and clinical factors including prior surgical factors were not significantly associated with clinical insomnia. Conclusions Insomnia should be addressed as a critical part of pain management in FBSS patients with these risk factors, especially in patients with high pain catastrophizing.

  11. A randomized clinical trial comparing mandibular incisor proclination produced by fixed labial appliances and clear aligners.

    PubMed

    Hennessy, Joe; Garvey, Thérèse; Al-Awadhi, Ebrahim A

    2016-09-01

    To compare the mandibular incisor proclination produced by fixed labial appliances and third generation clear aligners. Patients underwent a course of orthodontic treatment using either fixed labial appliances or clear aligners (Invisalign). Mandibular incisor proclination was measured by comparing pretreatment and near-end treatment lateral cephalograms. Eligibility criteria included adult patients with mild mandibular incisor crowding (<4 mm) and Class I skeletal bases (ANB, 1-4°). The main outcome was the cephalometric change in mandibular incisor inclination to the mandibular plane at the end of treatment. Eligible patients picking a sealed opaque envelope, which indicated their group allocation, was used to achieve randomization. Data was analyzed using a Welch two-sample t-test. Forty-four patients (mean age, 26.4 ± 7.7 years) were randomized in a 1:1 ratio to either the fixed labial appliance or the clear aligner group. Baseline characteristics were similar for both groups: Fixed appliance mean crowding was 2.1 ± 1.3 mm vs clear aligner mean crowding, 2.5 ± 1.3 mm; pretreatment mean mandibular incisor inclination for the fixed appliance group was 90.8 ± 5.4° vs 91.6 ± 6.4° for the clear aligner group. Fixed appliances produced 5.3 ± 4.3° of mandibular incisor proclination. Clear aligners proclined the mandibular incisors by 3.4 ± 3.2°. The difference between the two groups was not statistically significant (P > .05). There was no difference in the amount of mandibular incisor proclination produced by clear aligners and fixed labial appliances in mild crowding cases.

  12. An "XL" endodontics intervention for dental students required to repeat the course: changing frustration to improved grades and attitudes.

    PubMed

    Alcota, Marcela; Fuenzalida, Alejandra; Barrientos, Claudia; Garrido, Mauricio; Ruiz de Gauna, Pilar; González, Fermín E

    2015-04-01

    Given the psychological and financial costs involved with failing a clinical course, especially in developing countries, an alternative educational method was tested with students who had to repeat the year-long endodontic course at the University of Chile Faculty of Dentistry. The objectives of the intervention were to deepen theoretical knowledge and practical experiences, as well as to reinforce personal confidence in an endodontic clinical setting for students who failed the regular endodontic course. The aim of this study was to evaluate the success of this new model of educational intervention. In the study, 28 students who had failed the endodontic course repeated it with an alternative teaching method. The students attended patients immediately following practical competence exams, and they had access to simulated models that used rotary instruments and access cavities and had emergency care practice. Feedback sessions were held after each clinical session. Final grades were compared with those of other students who repeated the course without the intervention from 2007 to 2009. A survey was administered to understand the causes of initial failure and their opinions of the intervention. Students who participated in the alternative course did significantly better than their counterparts from previous years who did not receive the intervention (5.7±0.3 vs. 5.4±0.2; p<0.05). Their overall perception of the intervention was positive, and the main cause for previous course failure was personal insecurity and slow clinical care performance (54.2% of the students). The intervention course not only improved grades but also generated interest in endodontics, a contrasting perspective to the frustration students usually express after repeating the course. The results of this study support the introduction of similar interventions in endodontics and perhaps other courses.

  13. Trust, but verify - Accuracy of clinical commercial radiation Treatment Planning Systems

    NASA Astrophysics Data System (ADS)

    Lehmann, J.; Kenny, J.; Lye, J.; Dunn, L.; Williams, I.

    2014-03-01

    Computer based Treatment Planning Systems (TPS) are used worldwide to design and calculate treatment plans for treating radiation therapy patients. TPS are generally well designed and thoroughly tested by their developers and local physicists prior to clinical use. However, the wide-reaching impact of their accuracy warrants ongoing vigilance. This work reviews the findings of the Australian national audit system and provides recommendations for checks of TPS. The Australian Clinical Dosimetry Service (ACDS) has designed and implemented a national system of audits, currently in a three year test phase. The Level III audits verify the accuracy of a beam model of a facility's TPS through a comparison of measurements with calculation at selected points in an anthropomorphic phantom. The plans are prescribed by the ACDS and all measurement equipment is brought in for independent onsite measurements. In this first version of audits, plans are comparatively simple, involving asymmetric fields, wedges and inhomogeneities. The ACDS has performed 14 Level III audits to-date. Six audits returned at least one measurement at Action Level, indicating that the measured dose differed more than 3.3% (but less than 5%) from the planned dose. Two audits failed (difference >5%). One fail was caused by a data transmission error coupled with quality assurance (QA) not being performed. The second fail was investigated and reduced to Action Level with the onsite audit team finding phantom setup at treatment a contributing factor. The Action Level results are attributed to small dose calculation deviations within the TPS, which are investigated and corrected by the facilities. Small deviations exist in clinical TPS which can add up and can combine with output variations to result in unacceptable variations. Ongoing checks and independent audits are recommended.

  14. Modeling relationships between traditional preadmission measures and clinical skills performance on a medical licensure examination.

    PubMed

    Roberts, William L; Pugliano, Gina; Langenau, Erik; Boulet, John R

    2012-08-01

    Medical schools employ a variety of preadmission measures to select students most likely to succeed in the program. The Medical College Admission Test (MCAT) and the undergraduate college grade point average (uGPA) are two academic measures typically used to select students in medical school. The assumption that presently used preadmission measures can predict clinical skill performance on a medical licensure examination was evaluated within a validity argument framework (Kane 1992). A hierarchical generalized linear model tested relationships between the log-odds of failing a high-stakes medical licensure performance examination and matriculant academic and non-academic preadmission measures, controlling for student-and school-variables. Data includes 3,189 matriculants from 22 osteopathic medical schools tested in 2009-2010. Unconditional unit-specific model expected average log-odds of failing the examination across medical schools is -3.05 (se = 0.11) or 5%. Student-level estimated coefficients for MCAT Verbal Reasoning scores (0.03), Physical Sciences scores (0.05), Biological Sciences scores (0.04), uGPA(science) (0.07), and uGPA(non-science) (0.26) lacked association with the log-odds of failing the COMLEX-USA Level 2-PE, controlling for all other predictors in the model. Evidence from this study shows that present preadmission measures of academic ability are not related to later clinical skill performance. Given that clinical skill performance is an important part of medical practice, selection measures should be developed to identify students who will be successful in communication and be able to demonstrate the ability to systematically collect a medical history, perform a physical examination, and synthesize this information to diagnose and manage patient conditions.

  15. Chronic Kidney Disease and Medicines

    MedlinePlus

    ... If My Kidneys Fail? Clinical Trials Managing Chronic Kidney Disease If you have chronic kidney disease (CKD), ... hard, but it’s worthwhile. Ten ways to manage kidney disease Control your blood pressure Meet your blood ...

  16. Studying the Child Obesity Epidemic With Natural Experiments. NBER Working Paper No. 14989

    ERIC Educational Resources Information Center

    Sandy, Robert; Liu, Gilbert; Ottensmann, John; Tchernis, Rusty; Wilson, Jeffrey; Ford, O.T.

    2009-01-01

    We utilize clinical records of successive visits by children to pediatric clinics in Indianapolis to estimate the effects on their body mass of environmental changes near their homes. We compare results for fixed-residence children with those for cross-sectional data. Our environmental factors are fast food restaurants, supermarkets, parks,…

  17. Corneal graft reversal: Histopathologic report of two cases

    PubMed Central

    Qahtani, Abdullah A.; Alkatan, Hind M.

    2014-01-01

    Graft reversal is a rare cause for failed PKP. In this case report we are presenting 2 graft failure cases in which the corneal grafts were reversed unintentionally. The onset of signs of graft failure, however was variable. We have included their clinical course and the histopathologic findings of the removed corneal grafts. A total of 6 cases including ours have been reported so far. The aim of this report is to attract the attention of corneal surgeons to an additional rare cause for failed penetrating keratoplasty (PKP) which is donor graft reversal. PMID:25473355

  18. Corneal graft reversal: Histopathologic report of two cases.

    PubMed

    Qahtani, Abdullah A; Alkatan, Hind M

    2014-10-01

    Graft reversal is a rare cause for failed PKP. In this case report we are presenting 2 graft failure cases in which the corneal grafts were reversed unintentionally. The onset of signs of graft failure, however was variable. We have included their clinical course and the histopathologic findings of the removed corneal grafts. A total of 6 cases including ours have been reported so far. The aim of this report is to attract the attention of corneal surgeons to an additional rare cause for failed penetrating keratoplasty (PKP) which is donor graft reversal.

  19. Designing effective drug and device development programs for hospitalized heart failure: A proposal for pretrial registries

    PubMed Central

    Greene, Stephen J.; Shah, Ami N.; Butler, Javed; Ambrosy, Andrew P.; Anker, Stefan D.; Chioncel, Ovidiu; Collins, Sean P.; Dinh, Wilfried; Dunnmon, Preston M.; Fonarow, Gregg C.; Lam, Carolyn S. P.; Mentz, Robert J.; Pieske, Burkert; Roessig, Lothar; Rosano, Giuseppe M. C.; Sato, Naoki; Vaduganathan, Muthiah; Gheorghiade, Mihai

    2014-01-01

    Recent international phase III clinical trials of novel therapies for hospitalized heart failure (HHF) have failed to improve the unacceptably high postdischarge event rate. These large studies have demonstrated notable geographic and site-specific variation in patient profiles and enrollment. Possible contributors to the lack of success in HHF outcome trials include challenges in selecting clinical sites capable of (1) providing adequate numbers of appropriately selected patients and (2) properly executing the study protocol. We propose a “pretrial registry” as a novel tool for improving the efficiency and quality of international HHF trials by focusing on the selection and cultivation of high-quality sites. A pretrial registry may help assess a site’s ability to achieve adequate enrollment of the target patient population, integrate protocol requirements into clinical workflow, and accomplish appropriate follow-up. Although such a process would be associated with additional upfront resource investment, this appropriation may be modest in comparison with the downstream costs associated with maintenance of poorly performing sites, failed clinical trials, and the global health and economic burden of HHF. This review is based on discussions between scientists, clinical trialists, and regulatory representatives regarding methods for improving international HHF trials that took place at the United States Food and Drug Administration on January 12th, 2012. PMID:25066552

  20. Load-bearing capacity of all-ceramic posterior inlay-retained fixed dental prostheses.

    PubMed

    Puschmann, Djamila; Wolfart, Stefan; Ludwig, Klaus; Kern, Matthias

    2009-06-01

    The purpose of this in vitro study was to compare the quasi-static load-bearing capacity of all-ceramic resin-bonded three-unit inlay-retained fixed dental prostheses (IRFDPs) made from computer-aided design/computer-aided manufacturing (CAD/CAM)-manufactured yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) frameworks with two different connector dimensions, with and without fatigue loading. Twelve IRFDPs each were made with connector dimensions 3 x 3 mm(2) (width x height) (control group) and 3 x 2 mm(2) (test group). Inlay-retained fixed dental prostheses were adhesively cemented on identical metal-models using composite resin cement. Subgroups of six specimens each were fatigued with maximal 1,200,000 loading cycles in a chewing simulator with a weight load of 25 kg and a load frequency of 1.5 Hz. The load-bearing capacity was tested in a universal testing machine for IRFDPs without fatigue loading and for IRFDPs that had not already fractured during fatigue loading. During fatigue testing one IRFDP (17%) of the test group failed. Under both loading conditions, IRFDPs of the control group exhibited statistically significantly higher load-bearing capacities than the test group. Fatigue loading reduced the load-bearing capacity in both groups. Considering the maximum chewing forces in the molar region, it seems possible to use zirconia ceramic as a core material for IRFDPs with a minimum connector dimension of 9 mm(2). A further reduction of the connector dimensions to 6 mm(2) results in a significant reduction of the load-bearing capacity.

Top