Sample records for clipped absolute deviation

  1. Patient-specific cardiac phantom for clinical training and preprocedure surgical planning.

    PubMed

    Laing, Justin; Moore, John; Vassallo, Reid; Bainbridge, Daniel; Drangova, Maria; Peters, Terry

    2018-04-01

    Minimally invasive mitral valve repair procedures including MitraClip ® are becoming increasingly common. For cases of complex or diseased anatomy, clinicians may benefit from using a patient-specific cardiac phantom for training, surgical planning, and the validation of devices or techniques. An imaging compatible cardiac phantom was developed to simulate a MitraClip ® procedure. The phantom contained a patient-specific cardiac model manufactured using tissue mimicking materials. To evaluate accuracy, the patient-specific model was imaged using computed tomography (CT), segmented, and the resulting point cloud dataset was compared using absolute distance to the original patient data. The result, when comparing the molded model point cloud to the original dataset, resulted in a maximum Euclidean distance error of 7.7 mm, an average error of 0.98 mm, and a standard deviation of 0.91 mm. The phantom was validated using a MitraClip ® device to ensure anatomical features and tools are identifiable under image guidance. Patient-specific cardiac phantoms may allow for surgical complications to be accounted for preoperative planning. The information gained by clinicians involved in planning and performing the procedure should lead to shorter procedural times and better outcomes for patients.

  2. A novel collaborative representation and SCAD based classification method for fibrosis and inflammatory activity analysis of chronic hepatitis C

    NASA Astrophysics Data System (ADS)

    Cai, Jiaxin; Chen, Tingting; Li, Yan; Zhu, Nenghui; Qiu, Xuan

    2018-03-01

    In order to analysis the fibrosis stage and inflammatory activity grade of chronic hepatitis C, a novel classification method based on collaborative representation (CR) with smoothly clipped absolute deviation penalty (SCAD) penalty term, called CR-SCAD classifier, is proposed for pattern recognition. After that, an auto-grading system based on CR-SCAD classifier is introduced for the prediction of fibrosis stage and inflammatory activity grade of chronic hepatitis C. The proposed method has been tested on 123 clinical cases of chronic hepatitis C based on serological indexes. Experimental results show that the performance of the proposed method outperforms the state-of-the-art baselines for the classification of fibrosis stage and inflammatory activity grade of chronic hepatitis C.

  3. Variable selection for zero-inflated and overdispersed data with application to health care demand in Germany

    PubMed Central

    Wang, Zhu; Shuangge, Ma; Wang, Ching-Yun

    2017-01-01

    In health services and outcome research, count outcomes are frequently encountered and often have a large proportion of zeros. The zero-inflated negative binomial (ZINB) regression model has important applications for this type of data. With many possible candidate risk factors, this paper proposes new variable selection methods for the ZINB model. We consider maximum likelihood function plus a penalty including the least absolute shrinkage and selection operator (LASSO), smoothly clipped absolute deviation (SCAD) and minimax concave penalty (MCP). An EM (expectation-maximization) algorithm is proposed for estimating the model parameters and conducting variable selection simultaneously. This algorithm consists of estimating penalized weighted negative binomial models and penalized logistic models via the coordinated descent algorithm. Furthermore, statistical properties including the standard error formulae are provided. A simulation study shows that the new algorithm not only has more accurate or at least comparable estimation, also is more robust than the traditional stepwise variable selection. The proposed methods are applied to analyze the health care demand in Germany using an open-source R package mpath. PMID:26059498

  4. Sparse Logistic Regression for Diagnosis of Liver Fibrosis in Rat by Using SCAD-Penalized Likelihood

    PubMed Central

    Yan, Fang-Rong; Lin, Jin-Guan; Liu, Yu

    2011-01-01

    The objective of the present study is to find out the quantitative relationship between progression of liver fibrosis and the levels of certain serum markers using mathematic model. We provide the sparse logistic regression by using smoothly clipped absolute deviation (SCAD) penalized function to diagnose the liver fibrosis in rats. Not only does it give a sparse solution with high accuracy, it also provides the users with the precise probabilities of classification with the class information. In the simulative case and the experiment case, the proposed method is comparable to the stepwise linear discriminant analysis (SLDA) and the sparse logistic regression with least absolute shrinkage and selection operator (LASSO) penalty, by using receiver operating characteristic (ROC) with bayesian bootstrap estimating area under the curve (AUC) diagnostic sensitivity for selected variable. Results show that the new approach provides a good correlation between the serum marker levels and the liver fibrosis induced by thioacetamide (TAA) in rats. Meanwhile, this approach might also be used in predicting the development of liver cirrhosis. PMID:21716672

  5. Variable selection for zero-inflated and overdispersed data with application to health care demand in Germany.

    PubMed

    Wang, Zhu; Ma, Shuangge; Wang, Ching-Yun

    2015-09-01

    In health services and outcome research, count outcomes are frequently encountered and often have a large proportion of zeros. The zero-inflated negative binomial (ZINB) regression model has important applications for this type of data. With many possible candidate risk factors, this paper proposes new variable selection methods for the ZINB model. We consider maximum likelihood function plus a penalty including the least absolute shrinkage and selection operator (LASSO), smoothly clipped absolute deviation (SCAD), and minimax concave penalty (MCP). An EM (expectation-maximization) algorithm is proposed for estimating the model parameters and conducting variable selection simultaneously. This algorithm consists of estimating penalized weighted negative binomial models and penalized logistic models via the coordinated descent algorithm. Furthermore, statistical properties including the standard error formulae are provided. A simulation study shows that the new algorithm not only has more accurate or at least comparable estimation, but also is more robust than the traditional stepwise variable selection. The proposed methods are applied to analyze the health care demand in Germany using the open-source R package mpath. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Empirical Performance of Cross-Validation With Oracle Methods in a Genomics Context.

    PubMed

    Martinez, Josue G; Carroll, Raymond J; Müller, Samuel; Sampson, Joshua N; Chatterjee, Nilanjan

    2011-11-01

    When employing model selection methods with oracle properties such as the smoothly clipped absolute deviation (SCAD) and the Adaptive Lasso, it is typical to estimate the smoothing parameter by m-fold cross-validation, for example, m = 10. In problems where the true regression function is sparse and the signals large, such cross-validation typically works well. However, in regression modeling of genomic studies involving Single Nucleotide Polymorphisms (SNP), the true regression functions, while thought to be sparse, do not have large signals. We demonstrate empirically that in such problems, the number of selected variables using SCAD and the Adaptive Lasso, with 10-fold cross-validation, is a random variable that has considerable and surprising variation. Similar remarks apply to non-oracle methods such as the Lasso. Our study strongly questions the suitability of performing only a single run of m-fold cross-validation with any oracle method, and not just the SCAD and Adaptive Lasso.

  7. Introducing the Mean Absolute Deviation "Effect" Size

    ERIC Educational Resources Information Center

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  8. Approximate message passing for nonconvex sparse regularization with stability and asymptotic analysis

    NASA Astrophysics Data System (ADS)

    Sakata, Ayaka; Xu, Yingying

    2018-03-01

    We analyse a linear regression problem with nonconvex regularization called smoothly clipped absolute deviation (SCAD) under an overcomplete Gaussian basis for Gaussian random data. We propose an approximate message passing (AMP) algorithm considering nonconvex regularization, namely SCAD-AMP, and analytically show that the stability condition corresponds to the de Almeida-Thouless condition in spin glass literature. Through asymptotic analysis, we show the correspondence between the density evolution of SCAD-AMP and the replica symmetric (RS) solution. Numerical experiments confirm that for a sufficiently large system size, SCAD-AMP achieves the optimal performance predicted by the replica method. Through replica analysis, a phase transition between replica symmetric and replica symmetry breaking (RSB) region is found in the parameter space of SCAD. The appearance of the RS region for a nonconvex penalty is a significant advantage that indicates the region of smooth landscape of the optimization problem. Furthermore, we analytically show that the statistical representation performance of the SCAD penalty is better than that of \

  9. Empirical Performance of Cross-Validation With Oracle Methods in a Genomics Context

    PubMed Central

    Martinez, Josue G.; Carroll, Raymond J.; Müller, Samuel; Sampson, Joshua N.; Chatterjee, Nilanjan

    2012-01-01

    When employing model selection methods with oracle properties such as the smoothly clipped absolute deviation (SCAD) and the Adaptive Lasso, it is typical to estimate the smoothing parameter by m-fold cross-validation, for example, m = 10. In problems where the true regression function is sparse and the signals large, such cross-validation typically works well. However, in regression modeling of genomic studies involving Single Nucleotide Polymorphisms (SNP), the true regression functions, while thought to be sparse, do not have large signals. We demonstrate empirically that in such problems, the number of selected variables using SCAD and the Adaptive Lasso, with 10-fold cross-validation, is a random variable that has considerable and surprising variation. Similar remarks apply to non-oracle methods such as the Lasso. Our study strongly questions the suitability of performing only a single run of m-fold cross-validation with any oracle method, and not just the SCAD and Adaptive Lasso. PMID:22347720

  10. Robust variable selection method for nonparametric differential equation models with application to nonlinear dynamic gene regulatory network analysis.

    PubMed

    Lu, Tao

    2016-01-01

    The gene regulation network (GRN) evaluates the interactions between genes and look for models to describe the gene expression behavior. These models have many applications; for instance, by characterizing the gene expression mechanisms that cause certain disorders, it would be possible to target those genes to block the progress of the disease. Many biological processes are driven by nonlinear dynamic GRN. In this article, we propose a nonparametric differential equation (ODE) to model the nonlinear dynamic GRN. Specially, we address following questions simultaneously: (i) extract information from noisy time course gene expression data; (ii) model the nonlinear ODE through a nonparametric smoothing function; (iii) identify the important regulatory gene(s) through a group smoothly clipped absolute deviation (SCAD) approach; (iv) test the robustness of the model against possible shortening of experimental duration. We illustrate the usefulness of the model and associated statistical methods through a simulation and a real application examples.

  11. Cardiac dimensional analysis by use of biplane cineradiography: description and validation of method.

    PubMed

    Lipscomb, K

    1980-01-01

    Biplane cineradiography is a potentially powerful tool for precise measurement of intracardiac dimensions. The most systematic approach to these measurements is the creation of a three-dimensional coordinate system within the x-ray field. Using this system, interpoint distances, such as between radiopaque clips or coronary artery bifurcations, can be calculated by use of the Pythagoras theorem. Alternatively, calibration factors can be calculated in order to determine the absolute dimensions of a structure, such as a ventricle or coronary artery. However, cineradiography has two problems that have precluded widespread use of the system. These problems are pincushion distortion and variable image magnification. In this paper, methodology to quantitate and compensate for these variables is presented. The method uses radiopaque beads permanently mounted in the x-ray field. The position of the bead images on the x-ray film determine the compensation factors. Using this system, measurements are made with a standard deviation of approximately 1% of the true value.

  12. Modeling the effect of toe clipping on treefrog survival: Beyond the return rate

    USGS Publications Warehouse

    Waddle, J.H.; Rice, K.G.; Mazzotti, F.J.; Percival, H.F.

    2008-01-01

    Some studies have described a negative effect of toe clipping on return rates of marked anurans, but the return rate is limited in that it does not account for heterogeneity of capture probabilities. We used open population mark-recapture models to estimate both apparent survival (ϕ) and the recapture probability (p) of two treefrog species individually marked by clipping 2–4 toes. We used information-theoretic model selection to examine the effect of toe clipping on survival while accounting for variation in capture probability. The model selection results indicate strong support for an effect of toe clipping on survival of Green Treefrogs (Hyla cinerea) and only limited support for an effect of toe clipping on capture probability. We estimate there was a mean absolute decrease in survival of 5.02% and 11.16% for Green Treefrogs with three and four toes removed, respectively, compared to individuals with just two toes removed. Results for Squirrel Treefrogs (Hyla squirella) indicate little support for an effect of toe clipping on survival but may indicate some support for a negative effect on capture probability. We believe that the return rate alone should not be used to examine survival of marked animals because constant capture probability must be assumed, and our examples demonstrate how capture probability may vary over time and among groups. Mark-recapture models provide a method for estimating the effect of toe clipping on anuran survival in situations where unique marks are applied.

  13. A Public Database of Immersive VR Videos with Corresponding Ratings of Arousal, Valence, and Correlations between Head Movements and Self Report Measures.

    PubMed

    Li, Benjamin J; Bailenson, Jeremy N; Pines, Adam; Greenleaf, Walter J; Williams, Leanne M

    2017-01-01

    Virtual reality (VR) has been proposed as a methodological tool to study the basic science of psychology and other fields. One key advantage of VR is that sharing of virtual content can lead to more robust replication and representative sampling. A database of standardized content will help fulfill this vision. There are two objectives to this study. First, we seek to establish and allow public access to a database of immersive VR video clips that can act as a potential resource for studies on emotion induction using virtual reality. Second, given the large sample size of participants needed to get reliable valence and arousal ratings for our video, we were able to explore the possible links between the head movements of the observer and the emotions he or she feels while viewing immersive VR. To accomplish our goals, we sourced for and tested 73 immersive VR clips which participants rated on valence and arousal dimensions using self-assessment manikins. We also tracked participants' rotational head movements as they watched the clips, allowing us to correlate head movements and affect. Based on past research, we predicted relationships between the standard deviation of head yaw and valence and arousal ratings. Results showed that the stimuli varied reasonably well along the dimensions of valence and arousal, with a slight underrepresentation of clips that are of negative valence and highly arousing. The standard deviation of yaw positively correlated with valence, while a significant positive relationship was found between head pitch and arousal. The immersive VR clips tested are available online as supplemental material.

  14. A Public Database of Immersive VR Videos with Corresponding Ratings of Arousal, Valence, and Correlations between Head Movements and Self Report Measures

    PubMed Central

    Li, Benjamin J.; Bailenson, Jeremy N.; Pines, Adam; Greenleaf, Walter J.; Williams, Leanne M.

    2017-01-01

    Virtual reality (VR) has been proposed as a methodological tool to study the basic science of psychology and other fields. One key advantage of VR is that sharing of virtual content can lead to more robust replication and representative sampling. A database of standardized content will help fulfill this vision. There are two objectives to this study. First, we seek to establish and allow public access to a database of immersive VR video clips that can act as a potential resource for studies on emotion induction using virtual reality. Second, given the large sample size of participants needed to get reliable valence and arousal ratings for our video, we were able to explore the possible links between the head movements of the observer and the emotions he or she feels while viewing immersive VR. To accomplish our goals, we sourced for and tested 73 immersive VR clips which participants rated on valence and arousal dimensions using self-assessment manikins. We also tracked participants' rotational head movements as they watched the clips, allowing us to correlate head movements and affect. Based on past research, we predicted relationships between the standard deviation of head yaw and valence and arousal ratings. Results showed that the stimuli varied reasonably well along the dimensions of valence and arousal, with a slight underrepresentation of clips that are of negative valence and highly arousing. The standard deviation of yaw positively correlated with valence, while a significant positive relationship was found between head pitch and arousal. The immersive VR clips tested are available online as supplemental material. PMID:29259571

  15. The Effectiveness of a Rater Training Booklet in Increasing Accuracy of Performance Ratings

    DTIC Science & Technology

    1988-04-01

    subjects’ ratings were compared for accuracy. The dependent measure was the absolute deviation score of each individual’s rating from the "true score". The...subjects’ ratings were compared for accuracy. The dependent measure was the absolute deviation score of each individual’s rating from the "true score". The...r IS % _. Findings: The absolute deviation scores of each individual’s ratings from the "true score" provided by subject matter experts were analyzed

  16. VARIABLE SELECTION FOR REGRESSION MODELS WITH MISSING DATA

    PubMed Central

    Garcia, Ramon I.; Ibrahim, Joseph G.; Zhu, Hongtu

    2009-01-01

    We consider the variable selection problem for a class of statistical models with missing data, including missing covariate and/or response data. We investigate the smoothly clipped absolute deviation penalty (SCAD) and adaptive LASSO and propose a unified model selection and estimation procedure for use in the presence of missing data. We develop a computationally attractive algorithm for simultaneously optimizing the penalized likelihood function and estimating the penalty parameters. Particularly, we propose to use a model selection criterion, called the ICQ statistic, for selecting the penalty parameters. We show that the variable selection procedure based on ICQ automatically and consistently selects the important covariates and leads to efficient estimates with oracle properties. The methodology is very general and can be applied to numerous situations involving missing data, from covariates missing at random in arbitrary regression models to nonignorably missing longitudinal responses and/or covariates. Simulations are given to demonstrate the methodology and examine the finite sample performance of the variable selection procedures. Melanoma data from a cancer clinical trial is presented to illustrate the proposed methodology. PMID:20336190

  17. Trans-Pacific tele-ultrasound image transmission of fetal central nervous system structures.

    PubMed

    Ferreira, Adilson Cunha; Araujo Júnior, Edward; Martins, Wellington P; Jordão, João Francisco; Oliani, Antônio Hélio; Meagher, Simon E; Da Silva Costa, Fabricio

    2015-01-01

    To assess the quality of images and video clips of fetal central nervous (CNS) structures obtained by ultrasound and transmitted via tele-ultrasound from Brazil to Australia. In this cross-sectional study, 15 normal singleton pregnant women between 20 and 26 weeks were selected. Fetal CNS structures were obtained by images and video clips. The exams were transmitted in real-time using a broadband internet and an inexpensive video streaming device. Four blinded examiners evaluated the quality of the exams using the Likert scale. We calculated the mean, standard deviation, mean difference, and p values were obtained from paired t tests. The quality of the original video clips was slightly better than that observed by the transmitted video clips; mean difference considering all observers = 0.23 points. In 47/60 comparisons (78.3%; 95% CI = 66.4-86.9%) the quality of the video clips were judged to be the same. In 182/240 still images (75.8%; 95% CI = 70.0-80.8%) the scores of transmitted image were considered the same as the original. We demonstrated that long distance tele-ultrasound transmission of fetal CNS structures using an inexpensive video streaming device provided images of subjective good quality.

  18. Forecasting Error Calculation with Mean Absolute Deviation and Mean Absolute Percentage Error

    NASA Astrophysics Data System (ADS)

    Khair, Ummul; Fahmi, Hasanul; Hakim, Sarudin Al; Rahim, Robbi

    2017-12-01

    Prediction using a forecasting method is one of the most important things for an organization, the selection of appropriate forecasting methods is also important but the percentage error of a method is more important in order for decision makers to adopt the right culture, the use of the Mean Absolute Deviation and Mean Absolute Percentage Error to calculate the percentage of mistakes in the least square method resulted in a percentage of 9.77% and it was decided that the least square method be worked for time series and trend data.

  19. Improvement of registration accuracy in accelerated partial breast irradiation using the point-based rigid-body registration algorithm for patients with implanted fiducial markers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inoue, Minoru; Yoshimura, Michio, E-mail: myossy@kuhp.kyoto-u.ac.jp; Sato, Sayaka

    2015-04-15

    Purpose: To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. Methods: Twenty-two consecutive patients were enrolled in a prospective trial examining 10-fraction APBI. Titanium clips were implanted intraoperatively around the seroma in all patients. For image-registration, the positions of the clips in daily kV x-ray images were matched to those in the planning digitally reconstructed radiographs. Fiducial and gravity registration errors (FREs and GREs, respectively), representing resulting misalignments of the edge and center of the target, respectively, were comparedmore » between the manual and algorithm-based methods. Results: In total, 218 fractions were evaluated. Although the mean FRE/GRE values for the manual and algorithm-based methods were within 3 mm (2.3/1.7 and 1.3/0.4 mm, respectively), the percentages of fractions where FRE/GRE exceeded 3 mm using the manual and algorithm-based methods were 18.8%/7.3% and 0%/0%, respectively. Manual registration resulted in 18.6% of patients with fractions of FRE/GRE exceeding 5 mm. The patients with larger clip deviation had significantly more fractions showing large FRE/GRE using manual registration. Conclusions: For image-registration using fiducial markers in APBI, the manual registration results in more fractions with considerable registration error due to loss of fiducial objectivity resulting from their deviation. The authors recommend the PRBR algorithm as a safe and effective strategy for accurate, image-guided registration and PTV margin reduction.« less

  20. Factors affecting accuracy in the Developmental Eye Movement Test measurement for Cantonese-speaking children.

    PubMed

    Pang, Peter C; Lam, Carly S; Woo, George C

    2010-09-01

    This study aims to determine the factors affecting the accuracy in the Developmental Eye Movement (DEM) test measurement for Cantonese-speaking children. The voices of 10 Cantonese-speaking children (aged between six and eight years) undertaking the vertical test (40 numbers) of the DEM test were recorded on a digital audio recorder. These voice clips were assessed by an experienced examiner to give the DEM test times. The examiner repeated the measurement five times for each voice clip and completed all 10 voice clips from the 10 children. The average of a single measurement, the mean of two, the mean of three and the mean of five repeated measurements were then compared. Five experienced and five inexperienced examiners of the DEM test were asked to record the results from five Cantonese-speaking children by listening to the playback of prerecorded audio clips. The deviation of the results from the preset values between the two groups was compared. There is no difference between the single measurement and those obtained by mean of two, three, four or five. Both experienced and inexperienced examiners obtained a higher deviation from the preset values in the adjusted compared with the non-adjusted times in both vertical and horizontal times. Experienced examiners measured the vertical times and adjusted vertical times significantly closer to the preset values than the inexperienced examiners (paired t-test, p < 0.05). The DEM test needs to be measured only once for an accurate time measurement. Inaccurate assessment of 'reading errors' in the DEM test can increase the inaccuracy of the adjusted times. It is suggested that an audio recording of the test be made to allow reassessment of reading errors. Experience in using the DEM test yields a more accurate DEM measurement as errors are detected more easily.

  1. Neuronavigated microvascular Doppler sonography for intraoperative monitoring of blood flow velocity changes during aneurysm surgery - a feasible monitoring technique.

    PubMed

    Malinova, Vesna; von Eckardstein, Kajetan; Rohde, Veit; Mielke, Dorothee

    2015-10-01

    The intraoperative microvascular Doppler sonography (iMDS) is a well-established tool in vascular surgery for blood flow velocity (BFV) monitoring, capable of detecting vessel occlusion. However, identification of subtotal vessel compromise is more difficult, since the measured BFV may substantially vary with changing insonation angles and insonated vessel segments. To keep these parameters constant we combined neuronavigation with iMDS (niMDS). The question was if niMDS allows the detection of subtotal vessel compromise in aneurysm surgery. During surgery, the 3-dimensional reconstruction of the CT-angiography, which was obtained routinely prior to surgery, was displayed by the neuronavigational system. Prior to clipping, neuronavigation was used to define target point and trajectory, which, by coupling the neuronavigational pointer with the Doppler probe, correspond to the insonated vessel segment and the insonation angle. After clipping, for each vessel segment, the same trajectory was used for all consecutive measurements. The mean BFVs pre- and post-clipping were documented. We performed 82 BFV-measurements in 39 aneurysm surgeries. Mean deviation between pre- and post-clipping BFV values was 2.12cm/s. There was a significant correlation between the mean BFV values before and after clipping (r=0.45 [95% CI 17-66%]; p=0.002). One patient experienced new neurological deficits due to occlusion of a perforating vessel that was not insonated. The study could not answer the question if niMDS can detect BFV changes after clipping indicating vessel compromise, as no subtotal vessel occlusion occurred in the 39 operations. However, we proofed that niMDS-measured BFVs only varied minimally in uncompromised vessels pre- and post-clipping, suggesting that vessel compromises might be easily detected during aneurysm surgery. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Majorization Minimization by Coordinate Descent for Concave Penalized Generalized Linear Models

    PubMed Central

    Jiang, Dingfeng; Huang, Jian

    2013-01-01

    Recent studies have demonstrated theoretical attractiveness of a class of concave penalties in variable selection, including the smoothly clipped absolute deviation and minimax concave penalties. The computation of the concave penalized solutions in high-dimensional models, however, is a difficult task. We propose a majorization minimization by coordinate descent (MMCD) algorithm for computing the concave penalized solutions in generalized linear models. In contrast to the existing algorithms that use local quadratic or local linear approximation to the penalty function, the MMCD seeks to majorize the negative log-likelihood by a quadratic loss, but does not use any approximation to the penalty. This strategy makes it possible to avoid the computation of a scaling factor in each update of the solutions, which improves the efficiency of coordinate descent. Under certain regularity conditions, we establish theoretical convergence property of the MMCD. We implement this algorithm for a penalized logistic regression model using the SCAD and MCP penalties. Simulation studies and a data example demonstrate that the MMCD works sufficiently fast for the penalized logistic regression in high-dimensional settings where the number of covariates is much larger than the sample size. PMID:25309048

  3. Variable selection for distribution-free models for longitudinal zero-inflated count responses.

    PubMed

    Chen, Tian; Wu, Pan; Tang, Wan; Zhang, Hui; Feng, Changyong; Kowalski, Jeanne; Tu, Xin M

    2016-07-20

    Zero-inflated count outcomes arise quite often in research and practice. Parametric models such as the zero-inflated Poisson and zero-inflated negative binomial are widely used to model such responses. Like most parametric models, they are quite sensitive to departures from assumed distributions. Recently, new approaches have been proposed to provide distribution-free, or semi-parametric, alternatives. These methods extend the generalized estimating equations to provide robust inference for population mixtures defined by zero-inflated count outcomes. In this paper, we propose methods to extend smoothly clipped absolute deviation (SCAD)-based variable selection methods to these new models. Variable selection has been gaining popularity in modern clinical research studies, as determining differential treatment effects of interventions for different subgroups has become the norm, rather the exception, in the era of patent-centered outcome research. Such moderation analysis in general creates many explanatory variables in regression analysis, and the advantages of SCAD-based methods over their traditional counterparts render them a great choice for addressing this important and timely issues in clinical research. We illustrate the proposed approach with both simulated and real study data. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Use of a surgical rehearsal platform and improvement in aneurysm clipping measures: results of a prospective, randomized trial.

    PubMed

    Chugh, A Jessey; Pace, Jonathan R; Singer, Justin; Tatsuoka, Curtis; Hoffer, Alan; Selman, Warren R; Bambakidis, Nicholas C

    2017-03-01

    OBJECTIVE The field of neurosurgery is constantly undergoing improvements and advances, both in technique and technology. Cerebrovascular neurosurgery is no exception, with endovascular treatments changing the treatment paradigm. Clipping of aneurysms is still necessary, however, and advances are still being made to improve patient outcomes within the microsurgical treatment of aneurysms. Surgical rehearsal platforms are surgical simulators that offer the opportunity to rehearse a procedure prior to entering the operative suite. This study is designed to determine whether use of a surgical rehearsal platform in aneurysm surgery is helpful in decreasing aneurysm dissection time and clip manipulation of the aneurysm. METHODS The authors conducted a blinded, prospective, randomized study comparing key effort and time variables in aneurysm clip ligation surgery with and without preoperative use of the SuRgical Planner (SRP) surgical rehearsal platform. Initially, 40 patients were randomly assigned to either of two groups: one in which surgery was performed after use of the SRP (SRP group) and one in which surgery was performed without use of the SRP (control group). All operations were videotaped. After exclusion of 6 patients from the SRP group and 9 from the control group, a total of 25 surgical cases were analyzed by a reviewer blinded to group assignment. The videos were analyzed for total microsurgical time, number of clips used, and number of clip placement attempts. Means and standard deviations (SDs) were calculated and compared between groups. RESULTS The mean (± SD) amount of operative time per clip used was 920 ± 770 seconds in the SRP group and 1294 ± 678 seconds in the control group (p = 0.05). In addition, the mean values for the number of clip attempts, total operative time, ratio of clip attempts to clips used, and time per clip attempt were all lower in the SRP group, although the between-group differences were not statistically significant. CONCLUSIONS Preoperative rehearsal with SRP increased efficiency and safety in aneurysm microsurgery as demonstrated by the statistically significant improvement in time per clip used. Although the rest of the outcomes did not demonstrate statistically significant between-group differences, the fact that the SRP group showed improvement in mean values for all measures studied suggests that preoperative rehearsal may increase the efficiency and safety of aneurysm microsurgery. Future studies aimed at improving patient outcome and safety during surgical clipping of aneurysms will be needed to keep pace with the quickly advancing endovascular field.

  5. SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, H; Yoon, J; Lee, E

    Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed onmore » the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm.« less

  6. Validation of Mean Absolute Sea Level of the North Atlantic obtained from Drifter, Altimetry and Wind Data

    NASA Technical Reports Server (NTRS)

    Maximenko, Nikolai A.

    2003-01-01

    Mean absolute sea level reflects the deviation of the Ocean surface from geoid due to the ocean currents and is an important characteristic of the dynamical state of the ocean. Values of its spatial variations (order of 1 m) are generally much smaller than deviations of the geoid shape from ellipsoid (order of 100 m) that makes the derivation of the absolute mean sea level a difficult task for gravity and satellite altimetry observations. Technique used by Niiler et al. for computation of the absolute mean sea level in the Kuroshio Extension was then developed into more general method and applied by Niiler et al. (2003b) to the global Ocean. The method is based on the consideration of balance of horizontal momentum.

  7. 9 CFR 439.20 - Criteria for maintaining accreditation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...

  8. 9 CFR 439.20 - Criteria for maintaining accreditation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...

  9. 9 CFR 439.20 - Criteria for maintaining accreditation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...

  10. 9 CFR 439.20 - Criteria for maintaining accreditation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...

  11. 9 CFR 439.20 - Criteria for maintaining accreditation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...

  12. Newborn screening for cystic fibrosis with the chloride electrode and neutron activation analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guerson, C.T.; Sertel, H.; Guerkan, M.

    From third annual meeting of the European Working Group of Cystic Fibrosis; Erbach, Germany (6 Sep 1972). In 6,061 newborns, the chloride electrode technique was used for the detection of cystic fibrosis. The electrolyte values obtained were found to vary with the type of electrode used (45.9 plus or minus 9.9 mEq/l Beckman and 22.3 plus or minus 12 mEq/l Orion), and in both cases a value greater than the mean + 2 standard deviation was held as suspect and retested. In the group studied, the incidence of cystic fibrosis was calculated to be 1 in 3,000. In 590 ofmore » these cases the sodium values of nail clippings were measured by neutron activation analysis and were found to differ according to the washing method used; wash in vivo with ethanol 211.26 plus or minus 85.9 mEq/ kg water wash and acetone rinse 93.00 plus or minus 47.24 mEq/ kg; washing with H/sub 2/O/sub 2/ + absolute ethanol + diethyl ether, 183.42 plus or minus 61.26 mEq/k g. In addition, no correlation was found between chloride in sweat and the sodium content of nails. (auth)« less

  13. Ordinary Least Squares and Quantile Regression: An Inquiry-Based Learning Approach to a Comparison of Regression Methods

    ERIC Educational Resources Information Center

    Helmreich, James E.; Krog, K. Peter

    2018-01-01

    We present a short, inquiry-based learning course on concepts and methods underlying ordinary least squares (OLS), least absolute deviation (LAD), and quantile regression (QR). Students investigate squared, absolute, and weighted absolute distance functions (metrics) as location measures. Using differential calculus and properties of convex…

  14. Application of Mean of Absolute Deviation Method for the Selection of Best Nonlinear Component Based on Video Encryption

    NASA Astrophysics Data System (ADS)

    Anees, Amir; Khan, Waqar Ahmad; Gondal, Muhammad Asif; Hussain, Iqtadar

    2013-07-01

    The aim of this work is to make use of the mean of absolute deviation (MAD) method for the evaluation process of substitution boxes used in the advanced encryption standard. In this paper, we use the MAD technique to analyze some popular and prevailing substitution boxes used in encryption processes. In particular, MAD is applied to advanced encryption standard (AES), affine power affine (APA), Gray, Lui J., Residue Prime, S8 AES, SKIPJACK, and Xyi substitution boxes.

  15. Non-contrast 3D time-of-flight magnetic resonance angiography for visualization of intracranial aneurysms in patients with absolute contraindications to CT or MRI contrast.

    PubMed

    Yanamadala, Vijay; Sheth, Sameer A; Walcott, Brian P; Buchbinder, Bradley R; Buckley, Deidre; Ogilvy, Christopher S

    2013-08-01

    The preoperative evaluation of patients with intracranial aneurysms typically includes a contrast-enhanced vascular study, such as computed tomography angiography (CTA), magnetic resonance angiography (MRA), or digital subtraction angiography. However, there are numerous absolute and relative contraindications to the administration of imaging contrast agents, including pregnancy, severe contrast allergy, and renal insufficiency. Evaluation of patients with contrast contraindications thus presents a unique challenge. We identified three patients with absolute contrast contraindications who presented with intracranial aneurysms. One patient was pregnant, while the other two had previous severe anaphylactic reactions to iodinated contrast. Because of these contraindications to intravenous contrast, we performed non-contrast time-of-flight MRA with 3D reconstruction (TOF MRA with 3DR) with maximum intensity projections and volume renderings as part of the preoperative evaluation prior to successful open surgical clipping of the aneurysms. In the case of one paraclinoid aneurysm, a high-resolution non-contrast CT scan was also performed to assess the relationship of the aneurysm to the anterior clinoid process. TOF MRA with 3DR successfully identified the intracranial aneurysms and adequately depicted the surrounding microanatomy. Intraoperative findings were as predicted by the preoperative imaging studies. The aneurysms were successfully clip-obliterated, and the patients had uneventful post-operative courses. These cases demonstrate that non-contrast imaging is a viable modality to assess intracranial aneurysms as part of the surgical planning process in patients with contrast contraindications. TOF MRA with 3DR, in conjunction with high-resolution non-contrast CT when indicated, provides adequate visualization of the microanatomy of the aneurysm and surrounding structures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Enhance Video Film using Retnix method

    NASA Astrophysics Data System (ADS)

    Awad, Rasha; Al-Zuky, Ali A.; Al-Saleh, Anwar H.; Mohamad, Haidar J.

    2018-05-01

    An enhancement technique used to improve the studied video quality. Algorithms like mean and standard deviation are used as a criterion within this paper, and it applied for each video clip that divided into 80 images. The studied filming environment has different light intensity (315, 566, and 644Lux). This different environment gives similar reality to the outdoor filming. The outputs of the suggested algorithm are compared with the results before applying it. This method is applied into two ways: first, it is applied for the full video clip to get the enhanced film; second, it is applied for every individual image to get the enhanced image then compiler them to get the enhanced film. This paper shows that the enhancement technique gives good quality video film depending on a statistical method, and it is recommended to use it in different application.

  17. In vivo dosimetry for external photon treatments of head and neck cancers by diodes and TLDS.

    PubMed

    Tung, C J; Wang, H C; Lo, S H; Wu, J M; Wang, C J

    2004-01-01

    In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.

  18. An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willis, David J., E-mail: David.Willis@petermac.or; Royal Melbourne Institute of Technology University, Melbourne, Victoria; Kron, Tomas

    2011-07-01

    The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imagingmore » was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.« less

  19. Interactive Visual Least Absolutes Method: Comparison with the Least Squares and the Median Methods

    ERIC Educational Resources Information Center

    Kim, Myung-Hoon; Kim, Michelle S.

    2016-01-01

    A visual regression analysis using the least absolutes method (LAB) was developed, utilizing an interactive approach of visually minimizing the sum of the absolute deviations (SAB) using a bar graph in Excel; the results agree very well with those obtained from nonvisual LAB using a numerical Solver in Excel. These LAB results were compared with…

  20. Excitability of the Primary Motor Cortex Increases More Strongly with Slow- than with Normal-Speed Presentation of Actions

    PubMed Central

    Moriuchi, Takefumi; Iso, Naoki; Sagari, Akira; Ogahara, Kakuya; Kitajima, Eiji; Tanaka, Koji; Tabira, Takayuki; Higashi, Toshio

    2014-01-01

    Introduction The aim of the present study was to investigate how the speed of observed action affects the excitability of the primary motor cortex (M1), as assessed by the size of motor evoked potentials (MEPs) induced by transcranial magnetic stimulation (TMS). Methods Eighteen healthy subjects watched a video clip of a person catching a ball, played at three different speeds (normal-, half-, and quarter-speed). MEPs were induced by TMS when the model's hand had opened to the widest extent just before catching the ball (“open”) and when the model had just caught the ball (“catch”). These two events were locked to specific frames of the video clip (“phases”), rather than occurring at specific absolute times, so that they could easily be compared across different speeds. MEPs were recorded from the thenar (TH) and abductor digiti minimi (ADM) muscles of the right hand. Results The MEP amplitudes were higher when the subjects watched the video clip at low speed than when they watched the clip at normal speed. A repeated-measures ANOVA, with the factor VIDEO-SPEED, showed significant main effects. Bonferroni's post hoc test showed that the following MEP amplitude differences were significant: TH, normal vs. quarter; ADM, normal vs. half; and ADM, normal vs. quarter. Paired t-tests showed that the significant MEP amplitude differences between TMS phases under each speed condition were TH, “catch” higher than “open” at quarter speed; ADM, “catch” higher than “open” at half speed. Conclusions These results indicate that the excitability of M1 was higher when the observed action was played at low speed. Our findings suggest that the action observation system became more active when the subjects observed the video clip at low speed, because the subjects could then recognize the elements of action and intention in others. PMID:25479161

  1. Study of the optimum level of electrode placement for the evaluation of absolute lung resistivity with the Mk3.5 EIT system.

    PubMed

    Nebuya, S; Noshiro, M; Yonemoto, A; Tateno, S; Brown, B H; Smallwood, R H; Milnes, P

    2006-05-01

    Inter-subject variability has caused the majority of previous electrical impedance tomography (EIT) techniques to focus on the derivation of relative or difference measures of in vivo tissue resistivity. Implicit in these techniques is the requirement for a reference or previously defined data set. This study assesses the accuracy and optimum electrode placement strategy for a recently developed method which estimates an absolute value of organ resistivity without recourse to a reference data set. Since this measurement of tissue resistivity is absolute, in Ohm metres, it should be possible to use EIT measurements for the objective diagnosis of lung diseases such as pulmonary oedema and emphysema. However, the stability and reproducibility of the method have not yet been investigated fully. To investigate these problems, this study used a Sheffield Mk3.5 system which was configured to operate with eight measurement electrodes. As a result of this study, the absolute resistivity measurement was found to be insensitive to the electrode level between 4 and 5 cm above the xiphoid process. The level of the electrode plane was varied between 2 cm and 7 cm above the xiphoid process. Absolute lung resistivity in 18 normal subjects (age 22.6 +/- 4.9, height 169.1 +/- 5.7 cm, weight 60.6 +/- 4.5 kg, body mass index 21.2 +/- 1.6: mean +/- standard deviation) was measured during both normal and deep breathing for 1 min. Three sets of measurements were made over a period of several days on each of nine of the normal male subjects. No significant differences in absolute lung resistivity were found, either during normal tidal breathing between the electrode levels of 4 and 5 cm (9.3 +/- 2.4 Omega m, 9.6 +/- 1.9 Omega m at 4 and 5 cm, respectively: mean +/- standard deviation) or during deep breathing between the electrode levels of 4 and 5 cm (10.9 +/- 2.9 Omega m and 11.1 +/- 2.3 Omega m, respectively: mean +/- standard deviation). However, the differences in absolute lung resistivity between normal and deep tidal breathing at the same electrode level are significant. No significant difference was found in the coefficient of variation between the electrode levels of 4 and 5 cm (9.5 +/- 3.6%, 8.5 +/- 3.2% at 4 and 5 cm, respectively: mean +/- standard deviation in individual subjects). Therefore, the electrode levels of 4 and 5 cm above the xiphoid process showed reasonable reliability in the measurement of absolute lung resistivity both among individuals and over time.

  2. Estimating Accuracy of Land-Cover Composition From Two-Stage Clustering Sampling

    EPA Science Inventory

    Land-cover maps are often used to compute land-cover composition (i.e., the proportion or percent of area covered by each class), for each unit in a spatial partition of the region mapped. We derive design-based estimators of mean deviation (MD), mean absolute deviation (MAD), ...

  3. Special electronic distance meter calibration for precise engineering surveying industrial applications

    NASA Astrophysics Data System (ADS)

    Braun, Jaroslav; Štroner, Martin; Urban, Rudolf

    2015-05-01

    All surveying instruments and their measurements suffer from some errors. To refine the measurement results, it is necessary to use procedures restricting influence of the instrument errors on the measured values or to implement numerical corrections. In precise engineering surveying industrial applications the accuracy of the distances usually realized on relatively short distance is a key parameter limiting the resulting accuracy of the determined values (coordinates, etc.). To determine the size of systematic and random errors of the measured distances were made test with the idea of the suppression of the random error by the averaging of the repeating measurement, and reducing systematic errors influence of by identifying their absolute size on the absolute baseline realized in geodetic laboratory at the Faculty of Civil Engineering CTU in Prague. The 16 concrete pillars with forced centerings were set up and the absolute distances between the points were determined with a standard deviation of 0.02 millimetre using a Leica Absolute Tracker AT401. For any distance measured by the calibrated instruments (up to the length of the testing baseline, i.e. 38.6 m) can now be determined the size of error correction of the distance meter in two ways: Firstly by the interpolation on the raw data, or secondly using correction function derived by previous FFT transformation usage. The quality of this calibration and correction procedure was tested on three instruments (Trimble S6 HP, Topcon GPT-7501, Trimble M3) experimentally using Leica Absolute Tracker AT401. By the correction procedure was the standard deviation of the measured distances reduced significantly to less than 0.6 mm. In case of Topcon GPT-7501 is the nominal standard deviation 2 mm, achieved (without corrections) 2.8 mm and after corrections 0.55 mm; in case of Trimble M3 is nominal standard deviation 3 mm, achieved (without corrections) 1.1 mm and after corrections 0.58 mm; and finally in case of Trimble S6 is nominal standard deviation 1 mm, achieved (without corrections) 1.2 mm and after corrections 0.51 mm. Proposed procedure of the calibration and correction is in our opinion very suitable for increasing of the accuracy of the electronic distance measurement and allows the use of the common surveying instrument to achieve uncommonly high precision.

  4. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...

  5. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...

  6. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...

  7. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...

  8. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...

  9. Initial experience of percutaneous treatment of mitral regurgitation with MitraClip® therapy in Spain.

    PubMed

    Carrasco-Chinchilla, Fernando; Arzamendi, Dabit; Romero, Miguel; Gimeno de Carlos, Federico; Alonso-Briales, Juan Horacio; Li, Chi-Hion; Mesa, Maria Dolores; Arnold, Roman; Serrador Frutos, Ana María; Pan, Manuel; Roig, Eulalia; Rodríguez-Bailón, Isabel; de la Fuente Galán, Luis; Hernández, José María; Serra, Antonio; Suárez de Lezo, José

    2014-12-01

    Symptomatic mitral regurgitation has an unfavorable prognosis unless treated by surgery. However, the European registry of valvular heart disease reports that 49% of patients with this condition do not undergo surgery. Percutaneous treatment of mitral regurgitation with MitraClip® has been proved a safe, efficient adjunct to medical treatment in patients with this profile. The objective of the present study is to describe initial experience of MitraClip® therapy in Spain. Retrospective observational study including all patients treated between November 2011 and July 2013 at the 4 Spanish hospitals recording the highest numbers of implantations. A total of 62 patients (77.4% men) were treated, mainly for restrictive functional mitral regurgitation (85.4%) of grade III (37%) or grade IV (63%), mean (standard deviation) ejection fraction 36% (14%), and New York Heart Association functional class III (37%) or IV (63%). Device implantation was successful in 98% of the patients. At 1 year, 81.2% had mitral regurgitation ≤ 2 and 90.9% were in New York Heart Association functional class ≤ II. One periprocedural death occurred (sepsis at 20 days post-implantation) and another 3 patients died during follow-up (mean, 9.1 months). Two patients needed a second implantation due to partial dehiscence of the first device and 2 others underwent heart transplantation. In Spain, MitraClip® therapy has principally been aimed at patients with functional mitral regurgitation, significant systolic ventricular dysfunction, and high surgical risk. It is considered a safe alternative treatment, which can reduce mitral regurgitation and improve functional capacity. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  10. Characterizing Accuracy and Precision of Glucose Sensors and Meters

    PubMed Central

    2014-01-01

    There is need for a method to describe precision and accuracy of glucose measurement as a smooth continuous function of glucose level rather than as a step function for a few discrete ranges of glucose. We propose and illustrate a method to generate a “Glucose Precision Profile” showing absolute relative deviation (ARD) and /or %CV versus glucose level to better characterize measurement errors at any glucose level. We examine the relationship between glucose measured by test and comparator methods using linear regression. We examine bias by plotting deviation = (test – comparator method) versus glucose level. We compute the deviation, absolute deviation (AD), ARD, and standard deviation (SD) for each data pair. We utilize curve smoothing procedures to minimize the effects of random sampling variability to facilitate identification and display of the underlying relationships between ARD or %CV and glucose level. AD, ARD, SD, and %CV display smooth continuous relationships versus glucose level. Estimates of MARD and %CV are subject to relatively large errors in the hypoglycemic range due in part to a markedly nonlinear relationship with glucose level and in part to the limited number of observations in the hypoglycemic range. The curvilinear relationships of ARD and %CV versus glucose level are helpful when characterizing and comparing the precision and accuracy of glucose sensors and meters. PMID:25037194

  11. Robust Alternatives to the Standard Deviation in Processing of Physics Experimental Data

    NASA Astrophysics Data System (ADS)

    Shulenin, V. P.

    2016-10-01

    Properties of robust estimations of the scale parameter are studied. It is noted that the median of absolute deviations and the modified estimation of the average Gini differences have asymptotically normal distributions and bounded influence functions, are B-robust estimations, and hence, unlike the estimation of the standard deviation, are protected from the presence of outliers in the sample. Results of comparison of estimations of the scale parameter are given for a Gaussian model with contamination. An adaptive variant of the modified estimation of the average Gini differences is considered.

  12. Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length.

    PubMed

    Yoo, Jin Suk; Kwon, Kung-Rock; Noh, Kwantae; Lee, Hyeonjong; Paek, Janghyun

    2017-06-01

    The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed. Test model was created with epoxy resin. The strain gauges made a tight contact with implant surfaces. A universal testing machine was used to exert a vertical pressure on the mandibular implant overdenture and the strain rate of the implants was measured. Means and standard deviations of the maximum micro-deformation rates were determined. 1) Locator attachment: The implants on the working side generally showed higher strain than those on the non-working side. Tensile force was observed on the mesial surface of the implant on the working side, and the compressive force was applied to the buccal surface and on the surfaces of the implant on the non-working side. 2) Bar/clip attachment: The implants on the both non-working and working sides showed high strain; all surfaces except the mesial surface of the implant on the non-working side showed a compressive force. To minimize the strain on implants in mandibular implant overdentures, the attachment of the implant should be carefully selected and the denture base should be extended as much as possible.

  13. Patient-specific positioning guides for total knee arthroplasty: no significant difference between final component alignment and pre-operative digital plan except for tibial rotation.

    PubMed

    Boonen, Bert; Schotanus, Martijn G M; Kerens, Bart; Hulsmans, Frans-Jan; Tuinebreijer, Wim E; Kort, Nanne P

    2017-09-01

    To assess whether there is a significant difference between the alignment of the individual femoral and tibial components (in the frontal, sagittal and horizontal planes) as calculated pre-operatively (digital plan) and the actually achieved alignment in vivo obtained with the use of patient-specific positioning guides (PSPGs) for TKA. It was hypothesised that there would be no difference between post-op implant position and pre-op digital plan. Twenty-six patients were included in this non-inferiority trial. Software permitted matching of the pre-operative MRI scan (and therefore calculated prosthesis position) to a pre-operative CT scan and then to a post-operative full-leg CT scan to determine deviations from pre-op planning in all three anatomical planes. For the femoral component, mean absolute deviations from planning were 1.8° (SD 1.3), 2.5° (SD 1.6) and 1.6° (SD 1.4) in the frontal, sagittal and transverse planes, respectively. For the tibial component, mean absolute deviations from planning were 1.7° (SD 1.2), 1.7° (SD 1.5) and 3.2° (SD 3.6) in the frontal, sagittal and transverse planes, respectively. Absolute mean deviation from planned mechanical axis was 1.9°. The a priori specified null hypothesis for equivalence testing: the difference from planning is >3 or <-3 was rejected for all comparisons except for the tibial transverse plane. PSPG was able to adequately reproduce the pre-op plan in all planes, except for the tibial rotation in the transverse plane. Possible explanations for outliers are discussed and highlight the importance for adequate training surgeons before they start using PSPG in their day-by-day practise. Prospective cohort study, Level II.

  14. The absolute amplitude calibration of the SEASAT synthetic aperture radar - An intercomparison with other L-band radar systems

    NASA Technical Reports Server (NTRS)

    Held, D.; Werner, C.; Wall, S.

    1983-01-01

    The absolute amplitude calibration of the spaceborne Seasat SAR data set is presented based on previous relative calibration studies. A scale factor making it possible to express the perceived radar brightness of a scene in units of sigma-zero is established. The system components are analyzed for error contribution, and the calibration techniques are introduced for each stage. These include: A/D converter saturation tests; prevention of clipping in the processing step; and converting the digital image into the units of received power. Experimental verification was performed by screening and processing the data of the lava flow surrounding the Pisgah Crater in Southern California, for which previous C-130 airborne scatterometer data were available. The average backscatter difference between the two data sets is estimated to be 2 dB in the brighter, and 4 dB in the dimmer regions. For the SAR a calculated uncertainty of 3 dB is expected.

  15. Subsurface characterization with localized ensemble Kalman filter employing adaptive thresholding

    NASA Astrophysics Data System (ADS)

    Delijani, Ebrahim Biniaz; Pishvaie, Mahmoud Reza; Boozarjomehry, Ramin Bozorgmehry

    2014-07-01

    Ensemble Kalman filter, EnKF, as a Monte Carlo sequential data assimilation method has emerged promisingly for subsurface media characterization during past decade. Due to high computational cost of large ensemble size, EnKF is limited to small ensemble set in practice. This results in appearance of spurious correlation in covariance structure leading to incorrect or probable divergence of updated realizations. In this paper, a universal/adaptive thresholding method is presented to remove and/or mitigate spurious correlation problem in the forecast covariance matrix. This method is, then, extended to regularize Kalman gain directly. Four different thresholding functions have been considered to threshold forecast covariance and gain matrices. These include hard, soft, lasso and Smoothly Clipped Absolute Deviation (SCAD) functions. Three benchmarks are used to evaluate the performances of these methods. These benchmarks include a small 1D linear model and two 2D water flooding (in petroleum reservoirs) cases whose levels of heterogeneity/nonlinearity are different. It should be noted that beside the adaptive thresholding, the standard distance dependant localization and bootstrap Kalman gain are also implemented for comparison purposes. We assessed each setup with different ensemble sets to investigate the sensitivity of each method on ensemble size. The results indicate that thresholding of forecast covariance yields more reliable performance than Kalman gain. Among thresholding function, SCAD is more robust for both covariance and gain estimation. Our analyses emphasize that not all assimilation cycles do require thresholding and it should be performed wisely during the early assimilation cycles. The proposed scheme of adaptive thresholding outperforms other methods for subsurface characterization of underlying benchmarks.

  16. A TVSCAD approach for image deblurring with impulsive noise

    NASA Astrophysics Data System (ADS)

    Gu, Guoyong; Jiang, Suhong; Yang, Junfeng

    2017-12-01

    We consider image deblurring problem in the presence of impulsive noise. It is known that total variation (TV) regularization with L1-norm penalized data fitting (TVL1 for short) works reasonably well only when the level of impulsive noise is relatively low. For high level impulsive noise, TVL1 works poorly. The reason is that all data, both corrupted and noise free, are equally penalized in data fitting, leading to insurmountable difficulty in balancing regularization and data fitting. In this paper, we propose to combine TV regularization with nonconvex smoothly clipped absolute deviation (SCAD) penalty for data fitting (TVSCAD for short). Our motivation is simply that data fitting should be enforced only when an observed data is not severely corrupted, while for those data more likely to be severely corrupted, less or even null penalization should be enforced. A difference of convex functions algorithm is adopted to solve the nonconvex TVSCAD model, resulting in solving a sequence of TVL1-equivalent problems, each of which can then be solved efficiently by the alternating direction method of multipliers. Theoretically, we establish global convergence to a critical point of the nonconvex objective function. The R-linear and at-least-sublinear convergence rate results are derived for the cases of anisotropic and isotropic TV, respectively. Numerically, experimental results are given to show that the TVSCAD approach improves those of the TVL1 significantly, especially for cases with high level impulsive noise, and is comparable with the recently proposed iteratively corrected TVL1 method (Bai et al 2016 Inverse Problems 32 085004).

  17. Patient-specific atrium models for training and pre-procedure surgical planning

    NASA Astrophysics Data System (ADS)

    Laing, Justin; Moore, John; Bainbridge, Daniel; Drangova, Maria; Peters, Terry

    2017-03-01

    Minimally invasive cardiac procedures requiring a trans-septal puncture such as atrial ablation and MitraClip® mitral valve repair are becoming increasingly common. These procedures are performed on the beating heart, and require clinicians to rely on image-guided techniques. For cases of complex or diseased anatomy, in which fluoroscopic and echocardiography images can be difficult to interpret, clinicians may benefit from patient-specific atrial models that can be used for training, surgical planning, and the validation of new devices and guidance techniques. Computed tomography (CT) images of a patient's heart were segmented and used to generate geometric models to create a patient-specific atrial phantom. Using rapid prototyping, the geometric models were converted into physical representations and used to build a mold. The atria were then molded using tissue-mimicking materials and imaged using CT. The resulting images were segmented and used to generate a point cloud data set that could be registered to the original patient data. The absolute distance of the two point clouds was compared and evaluated to determine the model's accuracy. The result when comparing the molded model point cloud to the original data set, resulted in a maximum Euclidean distance error of 4.5 mm, an average error of 0.5 mm and a standard deviation of 0.6 mm. Using our workflow for creating atrial models, potential complications, particularly for complex repairs, may be accounted for in pre-operative planning. The information gained by clinicians involved in planning and performing the procedure should lead to shorter procedural times and better outcomes for patients.

  18. Adjusting head circumference for covariates in autism: clinical correlates of a highly heritable continuous trait.

    PubMed

    Chaste, Pauline; Klei, Lambertus; Sanders, Stephan J; Murtha, Michael T; Hus, Vanessa; Lowe, Jennifer K; Willsey, A Jeremy; Moreno-De-Luca, Daniel; Yu, Timothy W; Fombonne, Eric; Geschwind, Daniel; Grice, Dorothy E; Ledbetter, David H; Lord, Catherine; Mane, Shrikant M; Lese Martin, Christa; Martin, Donna M; Morrow, Eric M; Walsh, Christopher A; Sutcliffe, James S; State, Matthew W; Devlin, Bernie; Cook, Edwin H; Kim, Soo-Jeong

    2013-10-15

    Brain development follows a different trajectory in children with autism spectrum disorders (ASD) than in typically developing children. A proxy for neurodevelopment could be head circumference (HC), but studies assessing HC and its clinical correlates in ASD have been inconsistent. This study investigates HC and clinical correlates in the Simons Simplex Collection cohort. We used a mixed linear model to estimate effects of covariates and the deviation from the expected HC given parental HC (genetic deviation). After excluding individuals with incomplete data, 7225 individuals in 1891 families remained for analysis. We examined the relationship between HC/genetic deviation of HC and clinical parameters. Gender, age, height, weight, genetic ancestry, and ASD status were significant predictors of HC (estimate of the ASD effect = .2 cm). HC was approximately normally distributed in probands and unaffected relatives, with only a few outliers. Genetic deviation of HC was also normally distributed, consistent with a random sampling of parental genes. Whereas larger HC than expected was associated with ASD symptom severity and regression, IQ decreased with the absolute value of the genetic deviation of HC. Measured against expected values derived from covariates of ASD subjects, statistical outliers for HC were uncommon. HC is a strongly heritable trait, and population norms for HC would be far more accurate if covariates including genetic ancestry, height, and age were taken into account. The association of diminishing IQ with absolute deviation from predicted HC values suggests HC could reflect subtle underlying brain development and warrants further investigation. © 2013 Society of Biological Psychiatry.

  19. Adjusting head circumference for covariates in autism: clinical correlates of a highly heritable continuous trait

    PubMed Central

    Chaste, Pauline; Klei, Lambertus; Sanders, Stephan J.; Murtha, Michael T.; Hus, Vanessa; Lowe, Jennifer K.; Willsey, A. Jeremy; Moreno-De-Luca, Daniel; Yu, Timothy W.; Fombonne, Eric; Geschwind, Daniel; Grice, Dorothy E.; Ledbetter, David H.; Lord, Catherine; Mane, Shrikant M.; Martin, Christa Lese; Martin, Donna M.; Morrow, Eric M.; Walsh, Christopher A.; Sutcliffe, James S.; State, Matthew W.; Devlin, Bernie; Cook, Edwin H.; Kim, Soo-Jeong

    2013-01-01

    BACKGROUND Brain development follows a different trajectory in children with Autism Spectrum Disorders (ASD) than in typically developing children. A proxy for neurodevelopment could be head circumference (HC), but studies assessing HC and its clinical correlates in ASD have been inconsistent. This study investigates HC and clinical correlates in the Simons Simplex Collection cohort. METHODS We used a mixed linear model to estimate effects of covariates and the deviation from the expected HC given parental HC (genetic deviation). After excluding individuals with incomplete data, 7225 individuals in 1891 families remained for analysis. We examined the relationship between HC/genetic deviation of HC and clinical parameters. RESULTS Gender, age, height, weight, genetic ancestry and ASD status were significant predictors of HC (estimate of the ASD effect=0.2cm). HC was approximately normally distributed in probands and unaffected relatives, with only a few outliers. Genetic deviation of HC was also normally distributed, consistent with a random sampling of parental genes. Whereas larger HC than expected was associated with ASD symptom severity and regression, IQ decreased with the absolute value of the genetic deviation of HC. CONCLUSIONS Measured against expected values derived from covariates of ASD subjects, statistical outliers for HC were uncommon. HC is a strongly heritable trait and population norms for HC would be far more accurate if covariates including genetic ancestry, height and age were taken into account. The association of diminishing IQ with absolute deviation from predicted HC values suggests HC could reflect subtle underlying brain development and warrants further investigation. PMID:23746936

  20. Detection and evaluation of DNA methylation markers found at SCGN and KLF14 loci to estimate human age.

    PubMed

    Alghanim, Hussain; Antunes, Joana; Silva, Deborah Soares Bispo Santos; Alho, Clarice Sampaio; Balamurugan, Kuppareddi; McCord, Bruce

    2017-11-01

    Recent developments in the analysis of epigenetic DNA methylation patterns have demonstrated that certain genetic loci show a linear correlation with chronological age. It is the goal of this study to identify a new set of epigenetic methylation markers for the forensic estimation of human age. A total number of 27 CpG sites at three genetic loci, SCGN, DLX5 and KLF14, were examined to evaluate the correlation of their methylation status with age. These sites were evaluated using 72 blood samples and 91 saliva samples collected from volunteers with ages ranging from 5 to 73 years. DNA was bisulfite modified followed by PCR amplification and pyrosequencing to determine the level of DNA methylation at each CpG site. In this study, certain CpG sites in SCGN and KLF14 loci showed methylation levels that were correlated with chronological age, however, the tested CpG sites in DLX5 did not show a correlation with age. Using a 52-saliva sample training set, two age-predictor models were developed by means of a multivariate linear regression analysis for age prediction. The two models performed similarly with a single-locus model explaining 85% of the age variance at a mean absolute deviation of 5.8 years and a dual-locus model explaining 84% of the age variance with a mean absolute deviation of 6.2 years. In the validation set, the mean absolute deviation was measured to be 8.0 years and 7.1 years for the single- and dual-locus model, respectively. Another age predictor model was also developed using a 40-blood sample training set that accounted for 71% of the age variance. This model gave a mean absolute deviation of 6.6 years for the training set and 10.3years for the validation set. The results indicate that specific CpGs in SCGN and KLF14 can be used as potential epigenetic markers to estimate age using saliva and blood specimens. These epigenetic markers could provide important information in cases where the determination of a suspect's age is critical in developing investigative leads. Copyright © 2017. Published by Elsevier B.V.

  1. A critical assessment of two types of personal UV dosimeters.

    PubMed

    Seckmeyer, Gunther; Klingebiel, Marcus; Riechelmann, Stefan; Lohse, Insa; McKenzie, Richard L; Liley, J Ben; Allen, Martin W; Siani, Anna-Maria; Casale, Giuseppe R

    2012-01-01

    Doses of erythemally weighted irradiances derived from polysulphone (PS) and electronic ultraviolet (EUV) dosimeters have been compared with measurements obtained using a reference spectroradiometer. PS dosimeters showed mean absolute deviations of 26% with a maximum deviation of 44%, the calibrated EUV dosimeters showed mean absolute deviations of 15% (maximum 33%) around noon during several test days in the northern hemisphere autumn. In the case of EUV dosimeters, measurements with various cut-off filters showed that part of the deviation from the CIE erythema action spectrum was due to a small, but significant sensitivity to visible radiation that varies between devices and which may be avoided by careful preselection. Usually the method of calibrating UV sensors by direct comparison to a reference instrument leads to reliable results. However, in some circumstances the quality of measurements made with simple sensors may be over-estimated. In the extreme case, a simple pyranometer can be used as a UV instrument, providing acceptable results for cloudless skies, but very poor results under cloudy conditions. It is concluded that while UV dosimeters are useful for their design purpose, namely to estimate personal UV exposures, they should not be regarded as an inexpensive replacement for meteorological grade instruments. © 2011 Wiley Periodicals, Inc. Photochemistry and Photobiology © 2011 The American Society of Photobiology.

  2. Radar prediction of absolute rain fade distributions for earth-satellite paths and general methods for extrapolation of fade statistics to other locations

    NASA Technical Reports Server (NTRS)

    Goldhirsh, J.

    1982-01-01

    The first absolute rain fade distribution method described establishes absolute fade statistics at a given site by means of a sampled radar data base. The second method extrapolates absolute fade statistics from one location to another, given simultaneously measured fade and rain rate statistics at the former. Both methods employ similar conditional fade statistic concepts and long term rain rate distributions. Probability deviations in the 2-19% range, with an 11% average, were obtained upon comparison of measured and predicted levels at given attenuations. The extrapolation of fade distributions to other locations at 28 GHz showed very good agreement with measured data at three sites located in the continental temperate region.

  3. Analytical quality goals derived from the total deviation from patients' homeostatic set points, with a margin for analytical errors.

    PubMed

    Bolann, B J; Asberg, A

    2004-01-01

    The deviation of test results from patients' homeostatic set points in steady-state conditions may complicate interpretation of the results and the comparison of results with clinical decision limits. In this study the total deviation from the homeostatic set point is defined as the maximum absolute deviation for 95% of measurements, and we present analytical quality requirements that prevent analytical error from increasing this deviation to more than about 12% above the value caused by biology alone. These quality requirements are: 1) The stable systematic error should be approximately 0, and 2) a systematic error that will be detected by the control program with 90% probability, should not be larger than half the value of the combined analytical and intra-individual standard deviation. As a result, when the most common control rules are used, the analytical standard deviation may be up to 0.15 times the intra-individual standard deviation. Analytical improvements beyond these requirements have little impact on the interpretability of measurement results.

  4. Which Clip? A Prospective Comparative Study of Retention Rates of Endoscopic Clips on Normal Mucosa and Ulcers in a Porcine Model

    PubMed Central

    Saxena, Payal; Ji-Shin, Eun; Haito-Chavez, Yamile; Valeshabad, Ali K.; Akshintala, Venkata; Aguila, Gerard; Kumbhari, Vivek; Ruben, Dawn S.; Lennon, Anne-Marie; Singh, Vikesh; Canto, Marcia; Kalloo, Anthony; Khashab, Mouen A.

    2014-01-01

    Background/Aim: There are currently no data on the relative retention rates of the Instinct clip, Resolution clip, and QuickClip2Long. Also, it is unknown whether retention rate differs when clips are applied to ulcerated rather than normal mucosa. The aim of this study is to compare the retention rates of three commonly used endoscopic clips. Materials and Methods: Six pigs underwent upper endoscopy with placement of one of each of the three types of clips on normal mucosa in the gastric body. Three mucosal resections were also performed to create “ulcers”. Each ulcer was closed with placement of one of the three different clips. Repeat endoscopy was performed weekly for up to 4 weeks. Results: Only the Instinct and Resolution clips remained attached for the duration of the study (4 weeks). At each time point, a greater proportion of Instinct clips were retained on normal mucosa, followed by Resolution clips. QuickClip2Long had the lowest retention rate on normal mucosa. Similar retention rates of Instinct clips and Resolution clips were seen on simulated ulcers, although both were superior to QuickClip2Long. However, the difference did not reach statistical significance. All QuickClip2Long clips were dislodged at 4 weeks in both the groups. Conclusions: The Resolution and Instinct clips have comparable retention rates and both appeared to be better than the QuickClip2Long on normal mucosa-simulated ulcers; however this did not reach statistical significance. Both the Resolution clip and the Instinct clip may be preferred in clinical situations when long-term clip attachment is required, including marking of tumors for radiotherapy and anchoring feeding tubes or stents. Either of the currently available clips may be suitable for closure of iatrogenic mucosal defects without features of chronicity. PMID:25434317

  5. Density of Jatropha curcas Seed Oil and its Methyl Esters: Measurement and Estimations

    NASA Astrophysics Data System (ADS)

    Veny, Harumi; Baroutian, Saeid; Aroua, Mohamed Kheireddine; Hasan, Masitah; Raman, Abdul Aziz; Sulaiman, Nik Meriam Nik

    2009-04-01

    Density data as a function of temperature have been measured for Jatropha curcas seed oil, as well as biodiesel jatropha methyl esters at temperatures from above their melting points to 90 ° C. The data obtained were used to validate the method proposed by Spencer and Danner using a modified Rackett equation. The experimental and estimated density values using the modified Rackett equation gave almost identical values with average absolute percent deviations less than 0.03% for the jatropha oil and 0.04% for the jatropha methyl esters. The Janarthanan empirical equation was also employed to predict jatropha biodiesel densities. This equation performed equally well with average absolute percent deviations within 0.05%. Two simple linear equations for densities of jatropha oil and its methyl esters are also proposed in this study.

  6. Belief Propagation Algorithm for Portfolio Optimization Problems

    PubMed Central

    2015-01-01

    The typical behavior of optimal solutions to portfolio optimization problems with absolute deviation and expected shortfall models using replica analysis was pioneeringly estimated by S. Ciliberti et al. [Eur. Phys. B. 57, 175 (2007)]; however, they have not yet developed an approximate derivation method for finding the optimal portfolio with respect to a given return set. In this study, an approximation algorithm based on belief propagation for the portfolio optimization problem is presented using the Bethe free energy formalism, and the consistency of the numerical experimental results of the proposed algorithm with those of replica analysis is confirmed. Furthermore, the conjecture of H. Konno and H. Yamazaki, that the optimal solutions with the absolute deviation model and with the mean-variance model have the same typical behavior, is verified using replica analysis and the belief propagation algorithm. PMID:26305462

  7. Belief Propagation Algorithm for Portfolio Optimization Problems.

    PubMed

    Shinzato, Takashi; Yasuda, Muneki

    2015-01-01

    The typical behavior of optimal solutions to portfolio optimization problems with absolute deviation and expected shortfall models using replica analysis was pioneeringly estimated by S. Ciliberti et al. [Eur. Phys. B. 57, 175 (2007)]; however, they have not yet developed an approximate derivation method for finding the optimal portfolio with respect to a given return set. In this study, an approximation algorithm based on belief propagation for the portfolio optimization problem is presented using the Bethe free energy formalism, and the consistency of the numerical experimental results of the proposed algorithm with those of replica analysis is confirmed. Furthermore, the conjecture of H. Konno and H. Yamazaki, that the optimal solutions with the absolute deviation model and with the mean-variance model have the same typical behavior, is verified using replica analysis and the belief propagation algorithm.

  8. Fuzzy Random λ-Mean SAD Portfolio Selection Problem: An Ant Colony Optimization Approach

    NASA Astrophysics Data System (ADS)

    Thakur, Gour Sundar Mitra; Bhattacharyya, Rupak; Mitra, Swapan Kumar

    2010-10-01

    To reach the investment goal, one has to select a combination of securities among different portfolios containing large number of securities. Only the past records of each security do not guarantee the future return. As there are many uncertain factors which directly or indirectly influence the stock market and there are also some newer stock markets which do not have enough historical data, experts' expectation and experience must be combined with the past records to generate an effective portfolio selection model. In this paper the return of security is assumed to be Fuzzy Random Variable Set (FRVS), where returns are set of random numbers which are in turn fuzzy numbers. A new λ-Mean Semi Absolute Deviation (λ-MSAD) portfolio selection model is developed. The subjective opinions of the investors to the rate of returns of each security are taken into consideration by introducing a pessimistic-optimistic parameter vector λ. λ-Mean Semi Absolute Deviation (λ-MSAD) model is preferred as it follows absolute deviation of the rate of returns of a portfolio instead of the variance as the measure of the risk. As this model can be reduced to Linear Programming Problem (LPP) it can be solved much faster than quadratic programming problems. Ant Colony Optimization (ACO) is used for solving the portfolio selection problem. ACO is a paradigm for designing meta-heuristic algorithms for combinatorial optimization problem. Data from BSE is used for illustration.

  9. dCLIP: a computational approach for comparative CLIP-seq analyses

    PubMed Central

    2014-01-01

    Although comparison of RNA-protein interaction profiles across different conditions has become increasingly important to understanding the function of RNA-binding proteins (RBPs), few computational approaches have been developed for quantitative comparison of CLIP-seq datasets. Here, we present an easy-to-use command line tool, dCLIP, for quantitative CLIP-seq comparative analysis. The two-stage method implemented in dCLIP, including a modified MA normalization method and a hidden Markov model, is shown to be able to effectively identify differential binding regions of RBPs in four CLIP-seq datasets, generated by HITS-CLIP, iCLIP and PAR-CLIP protocols. dCLIP is freely available at http://qbrc.swmed.edu/software/. PMID:24398258

  10. Absolute Magnitude Calibration for Dwarfs Based on the Colour-Magnitude Diagrams of Galactic Clusters

    NASA Astrophysics Data System (ADS)

    Karaali, S.; Gökçe, E. Yaz; Bilir, S.; Güçtekin, S. Tunçel

    2014-07-01

    We present two absolute magnitude calibrations for dwarfs based on colour-magnitude diagrams of Galactic clusters. The combination of the Mg absolute magnitudes of the dwarf fiducial sequences of the clusters M92, M13, M5, NGC 2420, M67, and NGC 6791 with the corresponding metallicities provides absolute magnitude calibration for a given (g - r)0 colour. The calibration is defined in the colour interval 0.25 ≤ (g - r)0 ≤ 1.25 mag and it covers the metallicity interval - 2.15 ≤ [Fe/H] ≤ +0.37 dex. The absolute magnitude residuals obtained by the application of the procedure to another set of Galactic clusters lie in the interval - 0.15 ≤ ΔMg ≤ +0.12 mag. The mean and standard deviation of the residuals are < ΔMg > = - 0.002 and σ = 0.065 mag, respectively. The calibration of the MJ absolute magnitude in terms of metallicity is carried out by using the fiducial sequences of the clusters M92, M13, 47 Tuc, NGC 2158, and NGC 6791. It is defined in the colour interval 0.90 ≤ (V - J)0 ≤ 1.75 mag and it covers the same metallicity interval of the Mg calibration. The absolute magnitude residuals obtained by the application of the procedure to the cluster M5 ([Fe/H] = -1.40 dex) and 46 solar metallicity, - 0.45 ≤ [Fe/H] ≤ +0.35 dex, field stars lie in the interval - 0.29 and + 0.35 mag. However, the range of 87% of them is rather shorter, - 0.20 ≤ ΔMJ ≤ +0.20 mag. The mean and standard deviation of all residuals are < ΔMJ > =0.05 and σ = 0.13 mag, respectively. The derived relations are applicable to stars older than 4 Gyr for the Mg calibration, and older than 2 Gyr for the MJ calibration. The cited limits are the ages of the youngest calibration clusters in the two systems.

  11. Electronic Absolute Cartesian Autocollimator

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B.

    2006-01-01

    An electronic absolute Cartesian autocollimator performs the same basic optical function as does a conventional all-optical or a conventional electronic autocollimator but differs in the nature of its optical target and the manner in which the position of the image of the target is measured. The term absolute in the name of this apparatus reflects the nature of the position measurement, which, unlike in a conventional electronic autocollimator, is based absolutely on the position of the image rather than on an assumed proportionality between the position and the levels of processed analog electronic signals. The term Cartesian in the name of this apparatus reflects the nature of its optical target. Figure 1 depicts the electronic functional blocks of an electronic absolute Cartesian autocollimator along with its basic optical layout, which is the same as that of a conventional autocollimator. Referring first to the optical layout and functions only, this or any autocollimator is used to measure the compound angular deviation of a flat datum mirror with respect to the optical axis of the autocollimator itself. The optical components include an illuminated target, a beam splitter, an objective or collimating lens, and a viewer or detector (described in more detail below) at a viewing plane. The target and the viewing planes are focal planes of the lens. Target light reflected by the datum mirror is imaged on the viewing plane at unit magnification by the collimating lens. If the normal to the datum mirror is parallel to the optical axis of the autocollimator, then the target image is centered on the viewing plane. Any angular deviation of the normal from the optical axis manifests itself as a lateral displacement of the target image from the center. The magnitude of the displacement is proportional to the focal length and to the magnitude (assumed to be small) of the angular deviation. The direction of the displacement is perpendicular to the axis about which the mirror is slightly tilted. Hence, one can determine the amount and direction of tilt from the coordinates of the target image on the viewing plane.

  12. Resting-State Oscillatory Activity in Children Born Small for Gestational Age: An MEG Study

    PubMed Central

    Boersma, Maria; de Bie, Henrica M. A.; Oostrom, Kim J.; van Dijk, Bob W.; Hillebrand, Arjan; van Wijk, Bernadette C. M.; Delemarre-van de Waal, Henriëtte A.; Stam, Cornelis J.

    2013-01-01

    Growth restriction in utero during a period that is critical for normal growth of the brain, has previously been associated with deviations in cognitive abilities and brain anatomical and functional changes. We measured magnetoencephalography (MEG) in 4- to 7-year-old children to test if children born small for gestational age (SGA) show deviations in resting-state brain oscillatory activity. Children born SGA with postnatally spontaneous catch-up growth [SGA+; six boys, seven girls; mean age 6.3 year (SD = 0.9)] and children born appropriate for gestational age [AGA; seven boys, three girls; mean age 6.0 year (SD = 1.2)] participated in a resting-state MEG study. We calculated absolute and relative power spectra and used non-parametric statistics to test for group differences. SGA+ and AGA born children showed no significant differences in absolute and relative power except for reduced absolute gamma band power in SGA children. At the time of MEG investigation, SGA+ children showed significantly lower head circumference (HC) and a trend toward lower IQ, however there was no association of HC or IQ with absolute or relative power. Except for reduced absolute gamma band power, our findings suggest normal brain activity patterns at school age in a group of children born SGA in which spontaneous catch-up growth of bodily length after birth occurred. Although previous findings suggest that being born SGA alters brain oscillatory activity early in neonatal life, we show that these neonatal alterations do not persist at early school age when spontaneous postnatal catch-up growth occurs after birth. PMID:24068993

  13. A cadaveric study of the endoscopic endonasal transclival approach to the basilar artery.

    PubMed

    Lai, Leon T; Morgan, Michael K; Chin, David C W; Snidvongs, Kornkiat; Huang, June X Z; Malek, Joanne; Lam, Matthew; McLachlan, Rohan; Harvey, Richard J

    2013-04-01

    The anterior transclival route to basilar artery aneurysms is not widely performed. The objective of this study was to carry out a feasibility assessment of the transclival approach to basilar aneurysms with advanced endonasal techniques on 11 cadaver heads. Clival dura was exposed from the sella to the foramen magnum between the paraclival segments of the internal carotid arteries (ICA) laterally. An inverted dural "U" flap was reflected inferiorly to expose the basilar artery. The maximal dimensions from operative measurements were recorded. Surgical manoeuvrability of multiple instruments and the proficiency to place proximal and distal vascular clips were evaluated. The mean operative depth (± standard deviation), measured from the anterior choanae to the basilar artery, was 110±6mm. The lateral corridors were limited distally by the medial pterygoids (mean width 21±2mm) and paraclival ICA (mean width 20±2mm). The mean transclival craniectomy dimensions were 19±2mm (width) and 23±4mm (height). Exposure of the basilar-anterior inferior cerebellar artery junction, superior cerebellar artery, and the basilar caput were possible in 100%, 91%, and 64% of instances, respectively. Placements of proximal and distal aneurysm clips were achieved in all instances. Based on our findings, the transclival endoscopic endonasal surgery approach provides excellent visualisation of the basilar artery. Clip application and manoeuvrability of instruments was considered adequate for basilar aneurysm surgery. Surgical skills and instrumentation to control significant haemorrhage can potentially limit the clinical applicability of this technique. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  14. A suggestion for computing objective function in model calibration

    USGS Publications Warehouse

    Wu, Yiping; Liu, Shuguang

    2014-01-01

    A parameter-optimization process (model calibration) is usually required for numerical model applications, which involves the use of an objective function to determine the model cost (model-data errors). The sum of square errors (SSR) has been widely adopted as the objective function in various optimization procedures. However, ‘square error’ calculation was found to be more sensitive to extreme or high values. Thus, we proposed that the sum of absolute errors (SAR) may be a better option than SSR for model calibration. To test this hypothesis, we used two case studies—a hydrological model calibration and a biogeochemical model calibration—to investigate the behavior of a group of potential objective functions: SSR, SAR, sum of squared relative deviation (SSRD), and sum of absolute relative deviation (SARD). Mathematical evaluation of model performance demonstrates that ‘absolute error’ (SAR and SARD) are superior to ‘square error’ (SSR and SSRD) in calculating objective function for model calibration, and SAR behaved the best (with the least error and highest efficiency). This study suggests that SSR might be overly used in real applications, and SAR may be a reasonable choice in common optimization implementations without emphasizing either high or low values (e.g., modeling for supporting resources management).

  15. How well do static electronic dipole polarizabilities from gas-phase experiments compare with density functional and MP2 computations?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thakkar, Ajit J., E-mail: ajit@unb.ca; Wu, Taozhe

    2015-10-14

    Static electronic dipole polarizabilities for 135 molecules are calculated using second-order Møller-Plesset perturbation theory and six density functionals recently recommended for polarizabilities. Comparison is made with the best gas-phase experimental data. The lowest mean absolute percent deviations from the best experimental values for all 135 molecules are 3.03% and 3.08% for the LC-τHCTH and M11 functionals, respectively. Excluding the eight extreme outliers for which the experimental values are almost certainly in error, the mean absolute percent deviation for the remaining 127 molecules drops to 2.42% and 2.48% for the LC-τHCTH and M11 functionals, respectively. Detailed comparison enables us to identifymore » 32 molecules for which the discrepancy between the calculated and experimental values warrants further investigation.« less

  16. A comparison of portfolio selection models via application on ISE 100 index data

    NASA Astrophysics Data System (ADS)

    Altun, Emrah; Tatlidil, Hüseyin

    2013-10-01

    Markowitz Model, a classical approach to portfolio optimization problem, relies on two important assumptions: the expected return is multivariate normally distributed and the investor is risk averter. But this model has not been extensively used in finance. Empirical results show that it is very hard to solve large scale portfolio optimization problems with Mean-Variance (M-V)model. Alternative model, Mean Absolute Deviation (MAD) model which is proposed by Konno and Yamazaki [7] has been used to remove most of difficulties of Markowitz Mean-Variance model. MAD model don't need to assume that the probability of the rates of return is normally distributed and based on Linear Programming. Another alternative portfolio model is Mean-Lower Semi Absolute Deviation (M-LSAD), which is proposed by Speranza [3]. We will compare these models to determine which model gives more appropriate solution to investors.

  17. Geometric Verification of Dynamic Wave Arc Delivery With the Vero System Using Orthogonal X-ray Fluoroscopic Imaging.

    PubMed

    Burghelea, Manuela; Verellen, Dirk; Poels, Kenneth; Gevaert, Thierry; Depuydt, Tom; Tournel, Koen; Hung, Cecilia; Simon, Viorica; Hiraoka, Masahiro; de Ridder, Mark

    2015-07-15

    The purpose of this study was to define an independent verification method based on on-board orthogonal fluoroscopy to determine the geometric accuracy of synchronized gantry-ring (G/R) rotations during dynamic wave arc (DWA) delivery available on the Vero system. A verification method for DWA was developed to calculate O-ring-gantry (G/R) positional information from ball-bearing positions retrieved from fluoroscopic images of a cubic phantom acquired during DWA delivery. Different noncoplanar trajectories were generated in order to investigate the influence of path complexity on delivery accuracy. The G/R positions detected from the fluoroscopy images (DetPositions) were benchmarked against the G/R angulations retrieved from the control points (CP) of the DWA RT plan and the DWA log files recorded by the treatment console during DWA delivery (LogActed). The G/R rotational accuracy was quantified as the mean absolute deviation ± standard deviation. The maximum G/R absolute deviation was calculated as the maximum 3-dimensional distance between the CP and the closest DetPositions. In the CP versus DetPositions comparison, an overall mean G/R deviation of 0.13°/0.16° ± 0.16°/0.16° was obtained, with a maximum G/R deviation of 0.6°/0.2°. For the LogActed versus DetPositions evaluation, the overall mean deviation was 0.08°/0.15° ± 0.10°/0.10° with a maximum G/R of 0.3°/0.4°. The largest decoupled deviations registered for gantry and ring were 0.6° and 0.4° respectively. No directional dependence was observed between clockwise and counterclockwise rotations. Doubling the dose resulted in a double number of detected points around each CP, and an angular deviation reduction in all cases. An independent geometric quality assurance approach was developed for DWA delivery verification and was successfully applied on diverse trajectories. Results showed that the Vero system is capable of following complex G/R trajectories with maximum deviations during DWA below 0.6°. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. DAI-CLIPS: Distributed, Asynchronous, Interacting CLIPS

    NASA Technical Reports Server (NTRS)

    Gagne, Denis; Garant, Alain

    1994-01-01

    DAI-CLIPS is a distributed computational environment within which each CLIPS is an active independent computational entity with the ability to communicate freely with other CLIPS. Furthermore, new CLIPS can be created, others can be deleted or modify their expertise, all dynamically in an asynchronous and independent fashion during execution. The participating CLIPS are distributed over a network of heterogeneous processors taking full advantage of the available processing power. We present the general framework encompassing DAI-CLIPS and discuss some of its advantages and potential applications.

  19. Post-Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison Between Commercially Available Clips and Surgical Clip.

    PubMed

    Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula

    2018-02-01

    The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  20. Reducing the standard deviation in multiple-assay experiments where the variation matters but the absolute value does not.

    PubMed

    Echenique-Robba, Pablo; Nelo-Bazán, María Alejandra; Carrodeguas, José A

    2013-01-01

    When the value of a quantity x for a number of systems (cells, molecules, people, chunks of metal, DNA vectors, so on) is measured and the aim is to replicate the whole set again for different trials or assays, despite the efforts for a near-equal design, scientists might often obtain quite different measurements. As a consequence, some systems' averages present standard deviations that are too large to render statistically significant results. This work presents a novel correction method of a very low mathematical and numerical complexity that can reduce the standard deviation of such results and increase their statistical significance. Two conditions are to be met: the inter-system variations of x matter while its absolute value does not, and a similar tendency in the values of x must be present in the different assays (or in other words, the results corresponding to different assays must present a high linear correlation). We demonstrate the improvements this method offers with a cell biology experiment, but it can definitely be applied to any problem that conforms to the described structure and requirements and in any quantitative scientific field that deals with data subject to uncertainty.

  1. Cohesive energy and structural parameters of binary oxides of groups IIA and IIIB from diffusion quantum Monte Carlo

    DOE PAGES

    Santana, Juan A.; Krogel, Jaron T.; Kent, Paul R. C.; ...

    2016-05-03

    We have applied the diffusion quantum Monte Carlo (DMC) method to calculate the cohesive energy and the structural parameters of the binary oxides CaO, SrO, BaO, Sc 2O 3, Y 2O 3 and La 2O 3. The aim of our calculations is to systematically quantify the accuracy of the DMC method to study this type of metal oxides. The DMC results were compared with local and semi-local Density Functional Theory (DFT) approximations as well as with experimental measurements. The DMC method yields cohesive energies for these oxides with a mean absolute deviation from experimental measurements of 0.18(2) eV, while withmore » local and semi-local DFT approximations the deviation is 3.06 and 0.94 eV, respectively. For lattice constants, the mean absolute deviation in DMC, local and semi-local DFT approximations, are 0.017(1), 0.07 and 0.05 , respectively. In conclusion, DMC is highly accurate method, outperforming the local and semi-local DFT approximations in describing the cohesive energies and structural parameters of these binary oxides.« less

  2. A determination of the absolute radiant energy of a Robertson-Berger meter sunburn unit

    NASA Astrophysics Data System (ADS)

    DeLuisi, John J.; Harris, Joyce M.

    Data from a Robertson-Berger (RB) sunburn meter were compared with concurrent measurements obtained with an ultraviolet double monochromator (DM), and the absolute energy of one sunburn unit measured by the RB-meter was determined. It was found that at a solar zenith angle of 30° one sunburn unit (SU) is equivalent to 35 ± 4 mJ cm -2, and at a solar zenith angle of 69°, one SU is equivalent to 20 ± 2 mJ cm -2 (relative to a wavelength of 297 nm), where the rate of change is non-linear. The deviation is due to the different response functions of the RB-meter and the DM system used to simulate the response of human skin to the incident u.v. solar spectrum. The average growth rate of the deviation with increasing solar zenith angle was found to be 1.2% per degree between solar zenith angles 30 and 50° and 2.3% per degree between solar zenith angles 50 and 70°. The deviations of response with solar zenith angle were found to be consistent with reported RB-meter characteristics.

  3. A vibration-insensitive optical cavity and absolute determination of its ultrahigh stability.

    PubMed

    Zhao, Y N; Zhang, J; Stejskal, A; Liu, T; Elman, V; Lu, Z H; Wang, L J

    2009-05-25

    We use the three-cornered-hat method to evaluate the absolute frequency stabilities of three different ultrastable reference cavities, one of which has a vibration-insensitive design that does not even require vibration isolation. An Nd:YAG laser and a diode laser are implemented as light sources. We observe approximately 1 Hz beat note linewidths between all three cavities. The measurement demonstrates that the vibration-insensitive cavity has a good frequency stability over the entire measurement time from 100 ms to 200 s. An absolute, correlation-removed Allan deviation of 1.4 x 10(-15) at s of this cavity is obtained, giving a frequency uncertainty of only 0.44 Hz.

  4. How do we assign punishment? The impact of minimal and maximal standards on the evaluation of deviants.

    PubMed

    Kessler, Thomas; Neumann, Jörg; Mummendey, Amélie; Berthold, Anne; Schubert, Thomas; Waldzus, Sven

    2010-09-01

    To explain the determinants of negative behavior toward deviants (e.g., punishment), this article examines how people evaluate others on the basis of two types of standards: minimal and maximal. Minimal standards focus on an absolute cutoff point for appropriate behavior; accordingly, the evaluation of others varies dichotomously between acceptable or unacceptable. Maximal standards focus on the degree of deviation from that standard; accordingly, the evaluation of others varies gradually from positive to less positive. This framework leads to the prediction that violation of minimal standards should elicit punishment regardless of the degree of deviation, whereas punishment in response to violations of maximal standards should depend on the degree of deviation. Four studies assessed or manipulated the type of standard and degree of deviation displayed by a target. Results consistently showed the expected interaction between type of standard (minimal and maximal) and degree of deviation on punishment behavior.

  5. Intraoperative loss of core biopsy clips: clinical implications.

    PubMed

    Calhoun, Kristine; Giuliano, Armando; Brenner, R James

    2008-03-01

    The purpose of this study was to report the occurrence of intraoperative loss of metallic marking clips placed during image-guided biopsy and to hypothesize the likely mechanism of this clinical problem. From January 2003 through December 2004, patients presenting for preoperative mammographic localization and operative excision of biopsy site marking clips were identified. Age, method of image-guided biopsy, number of excised specimens, and tissue diagnosis were determined. Specimen radiographs were used to identify cases of suspected intraoperative clip loss. Clips absent on specimen radiographs and postoperative mammograms were defined as lost intraoperatively. Biopsy site marking clips, surgical clips, and suction device apertures were measured. In 78 surgical procedures performed during the study period, three (3.8%) of the patients experienced clip loss. Specimen radiographs confirmed the absence of clips in all submitted tissues. A median of four (range, three to five) separate biopsy specimens were excised among these three cases. A healing biopsy site from the stereotactic biopsy preceding the clip placement procedure was confirmed in all cases. Absence of the metallic clip was confirmed on postoperative mammograms. The apertures of two types of suction device were four and two times those of the biopsy clips. Intraoperative loss of metallic clips placed at the conclusion of image-guided breast biopsy is unusual but can occur during subsequent surgical excision. Repeated inability to locate the clip on specimen radiographs after accurate preoperative localization should raise the suspicion that the target clip has been lost, not missed, during surgery, likely because of inadvertent removal of the clip with the suction device.

  6. Diurnal Transcriptome and Gene Network Represented through Sparse Modeling in Brachypodium distachyon.

    PubMed

    Koda, Satoru; Onda, Yoshihiko; Matsui, Hidetoshi; Takahagi, Kotaro; Yamaguchi-Uehara, Yukiko; Shimizu, Minami; Inoue, Komaki; Yoshida, Takuhiro; Sakurai, Tetsuya; Honda, Hiroshi; Eguchi, Shinto; Nishii, Ryuei; Mochida, Keiichi

    2017-01-01

    We report the comprehensive identification of periodic genes and their network inference, based on a gene co-expression analysis and an Auto-Regressive eXogenous (ARX) model with a group smoothly clipped absolute deviation (SCAD) method using a time-series transcriptome dataset in a model grass, Brachypodium distachyon . To reveal the diurnal changes in the transcriptome in B. distachyon , we performed RNA-seq analysis of its leaves sampled through a diurnal cycle of over 48 h at 4 h intervals using three biological replications, and identified 3,621 periodic genes through our wavelet analysis. The expression data are feasible to infer network sparsity based on ARX models. We found that genes involved in biological processes such as transcriptional regulation, protein degradation, and post-transcriptional modification and photosynthesis are significantly enriched in the periodic genes, suggesting that these processes might be regulated by circadian rhythm in B. distachyon . On the basis of the time-series expression patterns of the periodic genes, we constructed a chronological gene co-expression network and identified putative transcription factors encoding genes that might be involved in the time-specific regulatory transcriptional network. Moreover, we inferred a transcriptional network composed of the periodic genes in B. distachyon , aiming to identify genes associated with other genes through variable selection by grouping time points for each gene. Based on the ARX model with the group SCAD regularization using our time-series expression datasets of the periodic genes, we constructed gene networks and found that the networks represent typical scale-free structure. Our findings demonstrate that the diurnal changes in the transcriptome in B. distachyon leaves have a sparse network structure, demonstrating the spatiotemporal gene regulatory network over the cyclic phase transitions in B. distachyon diurnal growth.

  7. Three-Dimensional Printing of Surgical Clips: An In Vitro Pilot Study and Trial of Efficacy.

    PubMed

    Canvasser, Noah E; De, Shuvro; Koseoglu, Ersin; Lay, Aaron H; Sorokin, Igor; Fernandez, Raul; Cadeddu, Jeffrey A

    2017-09-01

    Three-dimensional (3D) printing applications have increased over the past decade. Our objective was to test rapid prototyping of a 3D printed surgical clip for intraoperative use. Our prototype was modeled after the 10 mm Weck ® Hem-o-lok ® polymer clip (Teleflex, Inc., Wayne, PA). A 3D computer-aided design model of the Hem-o-lok clip was reverse engineered using commercial microscopy and printing was done using an Objet Connex500 multijetting system (Stratasys, Eden Prairie, MN). The initial polymer was Objet VeroWhitePlus RGD835; the addition of Objet TangoBlackPlus FLX980 during the design process improved hinge flexibility. The 3D printed clips were then pressure tested on rubber Penrose tubing and compared in vitro versus commercial Hem-o-lok clips. Initial 3D printed clips were not functional as they split at the hinge upon closure of the clip jaws. Design changes were made to add Objet TangoBlackPlus FLX980 at the hinge to improve flexibility. Additional modifications were made to allow for clips to be compatible with the Hem-o-lok endoscopic clip applier. A total of 50 clips were tested. Fracture rate for the printed clips using a clip applier was 54% (n = 27), whereas none of the commercial Hem-o-lok clips broke upon closure. Of the 23 printed clips that closed, mean leak was at 20.7 κPa (range 4.8-42.7). In contrast, none of the commercial clips leaked, and fill continued until Penrose rupture at mean 46.2 κPa (44.8-47.6). This pilot study demonstrates feasibility of 3D printing functional surgical clips. However, the performance of our first generation clips is poor compared with commercial grade product. Refinement in printers and materials available may allow for customization of such printed surgical instruments that could be economically competitive to purchasing and stocking product.

  8. Detection of esophageal fiducial marker displacement during radiation therapy with a 2-dimensional on-board imager: analysis of internal margin for esophageal cancer.

    PubMed

    Fukada, Junichi; Hanada, Takashi; Kawaguchi, Osamu; Ohashi, Toshio; Takeuchi, Hiroya; Kitagawa, Yuko; Seki, Satoshi; Shiraishi, Yutaka; Ogata, Haruhiko; Shigematsu, Naoyuki

    2013-03-15

    To quantify the interfraction displacement of esophageal fiducial markers for primary esophageal cancer radiation therapy. Orthogonal 2-dimensional (2D) matching records fused to vertebrae were analyzed in clinically staged T1/2N0 esophageal cancer patients undergoing endoscopic clipping as fiducial metal markers. Displacement of the markers between the digitally reconstructed radiographs and on-board kilovoltage images during radiation therapy was analyzed according to direction and esophageal site. Forty-four patients, with 81 markers (10 proximal, 42 middle, and 29 distal), underwent 367 2D matching sessions during radiation therapy. The mean (SD) absolute marker displacement was 0.26 (0.30) cm in the right-left (RL), 0.50 (0.39) cm in the superior-inferior (SI), and 0.24 (0.21) cm in the anterior-posterior (AP) direction. Displacement was significantly larger in the SI than in the RL and AP directions (P<.0001). In the SI direction, mean absolute displacements of the distal, middle, and proximal esophagus were 0.67 (0.45) cm, 0.42 (0.32) cm, and 0.36 (0.30) cm, respectively. Distal esophagus displacement was significantly larger than those of the middle and proximal esophagus (P<.0001). The estimated internal margin to cover 95% of the cases was 0.75 cm in the RL and AP directions. In the SI direction, the margin was 1.25 cm for the proximal and middle esophagus and 1.75 cm for the distal esophagus. The magnitude of interfraction displacement of esophageal clips was larger in the SI direction, particularly in the distal esophagus, but substantial displacement was observed in other directions and at other esophageal sites. It is practical to take estimated movements into account with internal margins, even if vertebrae-based 2D matching is performed. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Detection of Esophageal Fiducial Marker Displacement During Radiation Therapy With a 2-dimensional On-board Imager: Analysis of Internal Margin for Esophageal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fukada, Junichi, E-mail: fukada@rad.med.keio.ac.jp; Hanada, Takashi; Kawaguchi, Osamu

    Purpose: To quantify the interfraction displacement of esophageal fiducial markers for primary esophageal cancer radiation therapy. Methods and Materials: Orthogonal 2-dimensional (2D) matching records fused to vertebrae were analyzed in clinically staged T1/2N0 esophageal cancer patients undergoing endoscopic clipping as fiducial metal markers. Displacement of the markers between the digitally reconstructed radiographs and on-board kilovoltage images during radiation therapy was analyzed according to direction and esophageal site. Results: Forty-four patients, with 81 markers (10 proximal, 42 middle, and 29 distal), underwent 367 2D matching sessions during radiation therapy. The mean (SD) absolute marker displacement was 0.26 (0.30) cm in themore » right–left (RL), 0.50 (0.39) cm in the superior–inferior (SI), and 0.24 (0.21) cm in the anterior–posterior (AP) direction. Displacement was significantly larger in the SI than in the RL and AP directions (P<.0001). In the SI direction, mean absolute displacements of the distal, middle, and proximal esophagus were 0.67 (0.45) cm, 0.42 (0.32) cm, and 0.36 (0.30) cm, respectively. Distal esophagus displacement was significantly larger than those of the middle and proximal esophagus (P<.0001). The estimated internal margin to cover 95% of the cases was 0.75 cm in the RL and AP directions. In the SI direction, the margin was 1.25 cm for the proximal and middle esophagus and 1.75 cm for the distal esophagus. Conclusions: The magnitude of interfraction displacement of esophageal clips was larger in the SI direction, particularly in the distal esophagus, but substantial displacement was observed in other directions and at other esophageal sites. It is practical to take estimated movements into account with internal margins, even if vertebrae-based 2D matching is performed.« less

  10. Simulation and analysis of spectroscopic filter of rotational Raman lidar for absolute measurement of atmospheric temperature

    NASA Astrophysics Data System (ADS)

    Li, Qimeng; Li, Shichun; Hu, Xianglong; Zhao, Jing; Xin, Wenhui; Song, Yuehui; Hua, Dengxin

    2018-01-01

    The absolute measurement technique for atmospheric temperature can avoid the calibration process and improve the measurement accuracy. To achieve the rotational Raman temperature lidar of absolute measurement, the two-stage parallel multi-channel spectroscopic filter combined a first-order blazed grating with a fiber Bragg grating is designed and its performance is tested. The parameters and the optical path structure of the core cascaded-device (micron-level fiber array) are optimized, the optical path of the primary spectroscope is simulated and the maximum centrifugal distortion of the rotational Raman spectrum is approximately 0.0031 nm, the centrifugal ratio of 0.69%. The experimental results show that the channel coefficients of the primary spectroscope are 0.67, 0.91, 0.67, 0.75, 0.82, 0.63, 0.87, 0.97, 0.89, 0.87 and 1 by using the twelfth channel as a reference and the average FWHM is about 0.44 nm. The maximum deviation between the experimental wavelength and the theoretical value is approximately 0.0398 nm, with the deviation degree of 8.86%. The effective suppression to elastic scattering signal are 30.6, 35.2, 37.1, 38.4, 36.8, 38.2, 41.0, 44.3, 44.0, 46.7 dB. That means, combined with the second spectroscope, the suppression at least is up to 65 dB. Therefore we can fine extract single rotational Raman line to achieve the absolute measurement technique.

  11. Correction of clipped pixels in color images.

    PubMed

    Xu, Di; Doutre, Colin; Nasiopoulos, Panos

    2011-03-01

    Conventional images store a very limited dynamic range of brightness. The true luma in the bright area of such images is often lost due to clipping. When clipping changes the R, G, B color ratios of a pixel, color distortion also occurs. In this paper, we propose an algorithm to enhance both the luma and chroma of the clipped pixels. Our method is based on the strong chroma spatial correlation between clipped pixels and their surrounding unclipped area. After identifying the clipped areas in the image, we partition the clipped areas into regions with similar chroma, and estimate the chroma of each clipped region based on the chroma of its surrounding unclipped region. We correct the clipped R, G, or B color channels based on the estimated chroma and the unclipped color channel(s) of the current pixel. The last step involves smoothing of the boundaries between regions of different clipping scenarios. Both objective and subjective experimental results show that our algorithm is very effective in restoring the color of clipped pixels. © 2011 IEEE

  12. Efficacy and safety of the remOVE System for OTSC® and FTRD® clip removal: data from a PMCF analysis.

    PubMed

    Caputo, Antonio; Schmidt, Arthur; Caca, Karel; Bauerfeind, Peter; Schostek, Sebastian; Ho, Chi-Nghia; Gottwald, Thomas; Schurr, Marc O

    2018-06-01

    The remOVE System (Ovesco Endoscopy AG, Tuebingen, Germany) is a medical device for the endoscopic removal of OTSC or FTRD clips (Ovesco Endoscopy AG, Tuebingen, Germany). The aim of this paper is to assess the efficacy and safety of this system. A total of 74 patients underwent clip extraction. The standard removal procedure comprises fragmenting the clip by applying an electrical direct current pulse at two opposing sides of the clip. Clip fragmentation was successful in 72 of 74 patients (97.3%). In two cases (2.7%) clip fragmentation was not possible. In nine cases (12.2%) a clip fragment could not be removed and was left in place. Complications occurred in three cases (4.1%): two minor bleedings near the clip removal site (2.7%), and one superficial mucosal tear resulting from clip fragment extraction (1.4%). Based on this study, the use of the remOVE System for OTSC or FTRD clip removal can be considered safe and effective.

  13. Modified CLIP with objective liver reserve assessment retains prognosis prediction for patients with advanced hepatocellular carcinoma.

    PubMed

    Shao, Yu-Yun; Liu, Tsung-Hao; Lee, Ying-Hui; Hsu, Chih-Hung; Cheng, Ann-Lii

    2016-07-01

    The Cancer of the Liver Italian Program (CLIP) score is a commonly used staging system for hepatocellular carcinoma (HCC) helpful with predicting prognosis of advanced HCC. CLIP uses the Child-Turcotte-Pugh (CTP) score to evaluate liver reserve. A new scoring system, the albumin-bilirubin (ALBI) grade, has been proposed as they objectively evaluate liver reserve. We examined whether the modification of CLIP with ALBI retained its prognosis prediction for patients with advanced HCC. We included patients who received first-line antiangiogenic therapy for advanced HCC. Liver reserve was assessed using CTP and ALBI scores, which were then incorporated into CLIP and ALBI-CLIP, respectively. To assess their efficacies of prognostic prediction, the Cox's proportional hazard model and concordance indexes were used. A total of 142 patients were included; 137 of them were classified CTP A and 5 patients CTP B. Patients could be divided into four or five groups with different prognosis according to CLIP and ALBI-CLIP, respectively. Higher R(2) (0.249 vs 0.216) and lower Akaike information criterion (995.0 vs 1001.1) were observed for ALBI-CLIP than for CLIP in the Cox's model predicting overall survival. ALBI-CLIP remained an independent predictor for overall survival when CLIP and ALBI-CLIP were simultaneously incorporated in Cox's models allowing variable selection with adjustment for hepatitis etiology, treatment, and performance status. The concordance index was also higher for ALBI-CLIP than for CLIP (0.724 vs 0.703). Modification of CLIP scoring with ALBI, which objectively assesses liver reserve, retains and might have improved prognosis prediction for advanced HCC. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  14. Rebleeding from clipped aneurysm after 35 years: Report of 2 cases

    PubMed Central

    Ishida, Atsushi; Matsuo, Seigo; Asakuno, Keizoh; Nemoto, Akio; Niimura, Kaku; Yoshimoto, Haruko; Shiramizu, Hideki; Yuzawa, Miki

    2015-01-01

    Background: A successfully applied clip for a ruptured aneurysm keeps the aneurysm's neck closed, preventing rerupture throughout the patient's life. Unfortunately, rebleeding from a clipped aneurysm does occur, but the likelihood declines with time. Since relatively old people suffer from subarachnoid hemorrhage, they die from diseases other than rebleeding, such as cancer. Therefore, rebleeding from a clipped aneurysm after two decades is quite rare. Case Description: Here, we report 2 cases of rerupture after an extremely long time since the initial clipping. In both cases, the old clip was removed, and the regrown gourd-shaped aneurysm was successfully obliterated. The clips in both cases were submitted to their manufacturers and inspected thoroughly. They were found to be second-generation, stainless steel clips, and were almost intact, even keeping their closing forces. In both cases, the clip existed on the surface of the newly made dome, and the previous dome completely disappeared. Conclusions: We experienced 2 cases of rebleeding from the clipped aneurysm after 35 years. In one of the cases, the clip was a Yasargil second generation stainless steel clip that retained its mechanical properties and surface elemental composition in vivo for a long time. These cases should be informative as they show extremely long-term course of a clip applied for a ruptured aneurysm. PMID:26322244

  15. Optic neuropathy after anterior communicating artery aneurysm clipping: 3 cases and techniques to address a correctable pitfall.

    PubMed

    Linzey, Joseph R; Chen, Kevin S; Savastano, Luis; Thompson, B Gregory; Pandey, Aditya S

    2018-06-01

    Brain shifts following microsurgical clip ligation of anterior communicating artery (ACoA) aneurysms can lead to mechanical compression of the optic nerve by the clip. Recognition of this condition and early repositioning of clips can lead to reversal of vision loss. The authors identified 3 patients with an afferent pupillary defect following microsurgical clipping of ACoA aneurysms. Different treatment options were used for each patient. All patients underwent reexploration, and the aneurysm clips were repositioned to prevent clip-related compression of the optic nerve. Near-complete restoration of vision was achieved at the last clinic follow-up visit in all 3 patients. Clip ligation of ACoA aneurysms has the potential to cause clip-related compression of the optic nerve. Postoperative visual examination is of utmost importance, and if any changes are discovered, reexploration should be considered as repositioning of the clips may lead to resolution of visual deterioration.

  16. Analysis of protein glycation in human fingernail clippings with near-infrared (NIR) spectroscopy as an alternative technique for the diagnosis of diabetes mellitus.

    PubMed

    Monteyne, Tinne; Coopman, Renaat; Kishabongo, Antoine S; Himpe, Jonas; Lapauw, Bruno; Shadid, Samyah; Van Aken, Elisabeth H; Berenson, Darja; Speeckaert, Marijn M; De Beer, Thomas; Delanghe, Joris R

    2018-05-11

    Glycated keratin allows the monitoring of average tissue glucose exposure over previous weeks. In the present study, we wanted to explore if near-infrared (NIR) spectroscopy could be used as a non-invasive diagnostic tool for assessing glycation in diabetes mellitus. A total of 52 patients with diabetes mellitus and 107 healthy subjects were enrolled in this study. A limited number (n=21) of nails of healthy subjects were glycated in vitro with 0.278 mol/L, 0.556 mol/L and 0.833 mol/L glucose solution to study the effect of glucose on the nail spectrum. Consequently, the nail clippings of the patients were analyzed using a Thermo Fisher Antaris II Near-IR Analyzer Spectrometer and near infrared (NIR) chemical imaging. Spectral classification (patients with diabetes mellitus vs. healthy subjects) was performed using partial least square discriminant analysis (PLS-DA). In vitro glycation resulted in peak sharpening between 4300 and 4400 cm-1 and spectral variations at 5270 cm-1 and between 6600 and 7500 cm-1. Similar regions encountered spectral deviations during analysis of the patients' nails. Optimization of the spectral collection parameters was necessary in order to distinguish a large dataset. Spectra had to be collected at 16 cm-1, 128 scans, region 4000-7500 cm-1. Using standard normal variate, Savitsky-Golay smoothing (7 points) and first derivative preprocessing allowed for the prediction of the test set with 100% correct assignments utilizing a PLS-DA model. Analysis of protein glycation in human fingernail clippings with NIR spectroscopy could be an alternative affordable technique for the diagnosis of diabetes mellitus.

  17. Automated rule-base creation via CLIPS-Induce

    NASA Technical Reports Server (NTRS)

    Murphy, Patrick M.

    1994-01-01

    Many CLIPS rule-bases contain one or more rule groups that perform classification. In this paper we describe CLIPS-Induce, an automated system for the creation of a CLIPS classification rule-base from a set of test cases. CLIPS-Induce consists of two components, a decision tree induction component and a CLIPS production extraction component. ID3, a popular decision tree induction algorithm, is used to induce a decision tree from the test cases. CLIPS production extraction is accomplished through a top-down traversal of the decision tree. Nodes of the tree are used to construct query rules, and branches of the tree are used to construct classification rules. The learned CLIPS productions may easily be incorporated into a large CLIPS system that perform tasks such as accessing a database or displaying information.

  18. CLIPS++: Embedding CLIPS into C++

    NASA Technical Reports Server (NTRS)

    Obermeyer, Lance; Miranker, Daniel P.

    1994-01-01

    This paper describes a set of C++ extensions to the CLIPS language and their embodiment in CLIPS++. These extensions and the implementation approach of CLIPS++ provide a new level of embeddability with C and C++. These extensions are a C++ include statement and a defcontainer construct; (include (c++-header-file.h)) and (defcontainer (c++-type)). The include construct allows C++ functions to be embedded in both the LHS and RHS of CLIPS rules. The header file in an include construct is the same header file the programmer uses for his/her own C++ code, independent of CLIPS. The defcontainer construct allows the inference engine to treat C++ class instances as CLIPS deftemplate facts. Consequently existing C++ class libraries may be transparently imported into CLIPS. These C++ types may use advanced features like inheritance, virtual functions, and templates. The implementation has been tested with several class libraries, including Rogue Wave Software's Tools.h++, GNU's libg++, and USL's C++ Standard Components. The execution speed of CLIPS++ has been determined to be 5 to 700 times the execution speed of CLIPS 6.0 (10 to 20X typical).

  19. Real-Time and Meter-Scale Absolute Distance Measurement by Frequency-Comb-Referenced Multi-Wavelength Interferometry.

    PubMed

    Wang, Guochao; Tan, Lilong; Yan, Shuhua

    2018-02-07

    We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direct synthetic wavelength interferometry is elaborately introduced by launching a fifth wavelength to extend a non-ambiguous range for meter-scale measurement. A linearity test performed comparatively with a He-Ne laser interferometer shows a residual error of less than 70.8 nm in peak-to-valley over a 3 m distance, and a 10 h distance comparison is demonstrated to gain fractional deviations of ~3 × 10 -8 versus 3 m distance. Test results reveal that the presented absolute interferometer enables precise, stable, and long-term distance measurements and facilitates absolute positioning applications such as large-scale manufacturing and space missions.

  20. Real-Time and Meter-Scale Absolute Distance Measurement by Frequency-Comb-Referenced Multi-Wavelength Interferometry

    PubMed Central

    Tan, Lilong; Yan, Shuhua

    2018-01-01

    We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direct synthetic wavelength interferometry is elaborately introduced by launching a fifth wavelength to extend a non-ambiguous range for meter-scale measurement. A linearity test performed comparatively with a He–Ne laser interferometer shows a residual error of less than 70.8 nm in peak-to-valley over a 3 m distance, and a 10 h distance comparison is demonstrated to gain fractional deviations of ~3 × 10−8 versus 3 m distance. Test results reveal that the presented absolute interferometer enables precise, stable, and long-term distance measurements and facilitates absolute positioning applications such as large-scale manufacturing and space missions. PMID:29414897

  1. National Economic Development Procedures Manual - Recreation. Volume 2. A Guide for Using the Contingent Value Methodology in Recreation Studies,

    DTIC Science & Technology

    1986-03-01

    Directly from Sample Bid VI-16 Example 3 VI-16 Determining the Zero Price Qiantity Demanded VI-26 Summary VI -31 CHAPrER VII, THE DETERMINATION OF NED...While the standard deviation and variance are absolute measures of dispersion, a relative measure of dispersion can also be computed. This measure is...refers to the closeness of fit between the estimates obtained from Zli e and the true population value. The only way of being absolutely i: o-.iat the

  2. Retrieval of Aerosol Optical Properties from Ground-Based Remote Sensing Measurements: Aerosol Asymmetry Factor and Single Scattering Albedo

    NASA Astrophysics Data System (ADS)

    Qie, L.; Li, Z.; Li, L.; Li, K.; Li, D.; Xu, H.

    2018-04-01

    The Devaux-Vermeulen-Li method (DVL method) is a simple approach to retrieve aerosol optical parameters from the Sun-sky radiance measurements. This study inherited the previous works of retrieving aerosol single scattering albedo (SSA) and scattering phase function, the DVL method was modified to derive aerosol asymmetric factor (g). To assess the algorithm performance at various atmospheric aerosol conditions, retrievals from AERONET observations were implemented, and the results are compared with AERONET official products. The comparison shows that both the DVL SSA and g were well correlated with those of AERONET. The RMSD and the absolute value of MBD deviations between the SSAs are 0.025 and 0.015 respectively, well below the AERONET declared SSA uncertainty of 0.03 for all wavelengths. For asymmetry factor g, the RMSD deviations are smaller than 0.02 and the absolute values of MBDs smaller than 0.01 at 675, 870 and 1020 nm bands. Then, considering several factors probably affecting retrieval quality (i.e. the aerosol optical depth (AOD), the solar zenith angle, and the sky residual error, sphericity proportion and Ångström exponent), the deviations for SSA and g of these two algorithms were calculated at varying value intervals. Both the SSA and g deviations were found decrease with the AOD and the solar zenith angle, and increase with sky residual error. However, the deviations do not show clear sensitivity to the sphericity proportion and Ångström exponent. This indicated that the DVL algorithm is available for both large, non-spherical particles and spherical particles. The DVL results are suitable for the evaluation of aerosol direct radiative effects of different aerosol types.

  3. CLIPS: An expert system building tool

    NASA Technical Reports Server (NTRS)

    Riley, Gary

    1991-01-01

    The C Language Integrated Production System (CLIPS) is an expert system building tool, which provides a complete environment for the development and delivery of rule and/or object based expert systems. CLIPS was specifically designed to provide a low cost option for developing and deploying expert system applications across a wide range of hardware platforms. The commercial potential of CLIPS is vast. Currently, CLIPS is being used by over 3,300 individuals throughout the public and private sector. Because the CLIPS source code is readily available, numerous groups have used CLIPS as a basis for their own expert system tools. To date, three commercially available tools have been derived from CLIPS. In general, the development of CLIPS has helped to improve the ability to deliver expert system technology throughout the public and private sectors for a wide range of applications and diverse computing environments.

  4. Inverse Monte Carlo in a multilayered tissue model: merging diffuse reflectance spectroscopy and laser Doppler flowmetry.

    PubMed

    Fredriksson, Ingemar; Burdakov, Oleg; Larsson, Marcus; Strömberg, Tomas

    2013-12-01

    The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion are estimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry (LDF). The DRS spectra (450 to 850 nm) are assessed at two source-detector separations (0.4 and 1.2 mm), allowing for a relative calibration routine, whereas LDF spectra are assessed at 1.2 mm in the same fiber-optic probe. Data are analyzed using nonlinear optimization in an inverse Monte Carlo technique by applying an adaptive multilayered tissue model based on geometrical, scattering, and absorbing properties, as well as RBC flow-speed information. Simulations of 250 tissue-like models including up to 2000 individual blood vessels were used to evaluate the method. The absolute root mean square (RMS) deviation between estimated and true oxygenation was 4.1 percentage units, whereas the relative RMS deviations for the RBC tissue fraction and perfusion were 19% and 23%, respectively. Examples of in vivo measurements on forearm and foot during common provocations are presented. The method offers several advantages such as simultaneous quantification of RBC tissue fraction and oxygenation and perfusion from the same, predictable, sampling volume. The perfusion estimate is speed resolved, absolute (% RBC×mm/s), and more accurate due to the combination with DRS.

  5. Inverse Monte Carlo in a multilayered tissue model: merging diffuse reflectance spectroscopy and laser Doppler flowmetry

    NASA Astrophysics Data System (ADS)

    Fredriksson, Ingemar; Burdakov, Oleg; Larsson, Marcus; Strömberg, Tomas

    2013-12-01

    The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion are estimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry (LDF). The DRS spectra (450 to 850 nm) are assessed at two source-detector separations (0.4 and 1.2 mm), allowing for a relative calibration routine, whereas LDF spectra are assessed at 1.2 mm in the same fiber-optic probe. Data are analyzed using nonlinear optimization in an inverse Monte Carlo technique by applying an adaptive multilayered tissue model based on geometrical, scattering, and absorbing properties, as well as RBC flow-speed information. Simulations of 250 tissue-like models including up to 2000 individual blood vessels were used to evaluate the method. The absolute root mean square (RMS) deviation between estimated and true oxygenation was 4.1 percentage units, whereas the relative RMS deviations for the RBC tissue fraction and perfusion were 19% and 23%, respectively. Examples of in vivo measurements on forearm and foot during common provocations are presented. The method offers several advantages such as simultaneous quantification of RBC tissue fraction and oxygenation and perfusion from the same, predictable, sampling volume. The perfusion estimate is speed resolved, absolute (% RBC×mm/s), and more accurate due to the combination with DRS.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morley, Steven

    The PyForecastTools package provides Python routines for calculating metrics for model validation, forecast verification and model comparison. For continuous predictands the package provides functions for calculating bias (mean error, mean percentage error, median log accuracy, symmetric signed bias), and for calculating accuracy (mean squared error, mean absolute error, mean absolute scaled error, normalized RMSE, median symmetric accuracy). Convenience routines to calculate the component parts (e.g. forecast error, scaled error) of each metric are also provided. To compare models the package provides: generic skill score; percent better. Robust measures of scale including median absolute deviation, robust standard deviation, robust coefficient ofmore » variation and the Sn estimator are all provided by the package. Finally, the package implements Python classes for NxN contingency tables. In the case of a multi-class prediction, accuracy and skill metrics such as proportion correct and the Heidke and Peirce skill scores are provided as object methods. The special case of a 2x2 contingency table inherits from the NxN class and provides many additional metrics for binary classification: probability of detection, probability of false detection, false alarm ration, threat score, equitable threat score, bias. Confidence intervals for many of these quantities can be calculated using either the Wald method or Agresti-Coull intervals.« less

  7. HyperCLIPS: A HyperCard interface to CLIPS

    NASA Technical Reports Server (NTRS)

    Pickering, Brad; Hill, Randall W., Jr.

    1990-01-01

    HyperCLIPS combines the intuitive, interactive user interface of the Apple Macintosh(TM) with the powerful symbolic computation of an expert system interpreter. HyperCard(TM) is an excellent environment for quickly developing the front end of an application with buttons, dialogs, and pictures, while the CLIPS interpreter provides a powerful inference engine for complex problem solving and analysis. By integrating HyperCard and CLIPS the advantages and uses of both packages are made available for a wide range of uses: rapid prototyping of knowledge-based expert systems, interactive simulations of physical systems, and intelligent control of hypertext processes, to name a few. Interfacing HyperCard and CLIPS is natural. HyperCard was designed to be extended through the use of external commands (XCMDs), and CLIPS was designed to be embedded through the use of the I/O router facilities and callable interface routines. With the exception of some technical difficulties which will be discussed later, HyperCLIPS implements this interface in a straight forward manner, using the facilities provided. An XCMD called 'ClipsX' was added to HyperCard to give access to the CLIPS routines: clear, load, reset, and run. And an I/O router was added to CLIPS to handle the communication of data between CLIPS and HyperCard.

  8. Development of a new biodegradable operative clip made of a magnesium alloy: Evaluation of its safety and tolerability for canine cholecystectomy.

    PubMed

    Yoshida, Toshihiko; Fukumoto, Takumi; Urade, Takeshi; Kido, Masahiro; Toyama, Hirochika; Asari, Sadaki; Ajiki, Tetsuo; Ikeo, Naoko; Mukai, Toshiji; Ku, Yonson

    2017-06-01

    Operative clips used to ligate vessels in abdominal operation usually are made of titanium. They remain in the body permanently and form metallic artifacts in computed tomography images, which impair accurate diagnosis. Although biodegradable magnesium instruments have been developed in other fields, the physical properties necessary for operative clips differ from those of other instruments. We developed a biodegradable magnesium-zinc-calcium alloy clip with good biologic compatibility and enough clamping capability as an operative clip. In this study, we verified the safety and tolerability of this clip for use in canine cholecystectomy. Nine female beagles were used. We performed cholecystectomy and ligated the cystic duct by magnesium alloy or titanium clips. The chronologic change of clips and artifact formation were compared at 1, 4, 12, 18, and 24 weeks postoperative by computed tomography. The animals were killed at the end of the observation period, and the clips were removed to evaluate their biodegradability. We also evaluated their effect on the living body by blood biochemistry data. The magnesium alloy clip formed much fewer artifacts than the titanium clip, and it was almost absorbed at 6 months postoperative. There were no postoperative complications and no elevation of constituent elements such as magnesium, calcium, and zinc during the observation period in both groups. The novel magnesium alloy clip demonstrated sufficient sealing capability for the cystic duct and proper biodegradability in canine models. The magnesium alloy clip revealed much fewer metallic artifacts in CT than the conventional titanium clip. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Comparison of holding strength of suture anchors for hepatic and renal parenchyma.

    PubMed

    Ames, Caroline D; Perrone, Juan M; Frisella, Alison J; Morrissey, Kevin; Landman, Jaime

    2005-12-01

    Various laparoscopic devices have been described for suture anchoring during solidorgan parenchymal closure. Application of these devices expedites the closure of parenchymal defects and minimizes ischemia time. We compared different technologies as suture anchors for parenchymal closure. A tensometer was used to determine the amount of tension necessary to dislodge each of five different clips from Vicryl suture alone or against two different substrates (fresh pig kidney and liver) with and without an intervening pledget. The clips investigated were the Lapra-Ty (Ethicon), Endoclip II (US Surgical), small Horizon Ligating Clips (Weck), Hem-o-lok Medium Polymer Clips (Week), and a novel Suture-clip (Applied Medical). ANOVA and two-sided Fisher's exact test provided statistical analysis. The force required to dislodge the Lapra-Ty clip from bare suture for both 0 and 1 Vicryl (7.0 N) was approximately fourfold the force required to dislodge the Endoclips or the 5-mm or 10-mm Hem-o-lok clips (p<0.01). When clips were applied to suture running through renal or liver parenchyma, the novel Suture-clip required the greatest tension to dislodge (P<0.01), followed by the Horizon and Lapra-Ty clips. There were no statistically significant differences in the tension required to dislodge a given clip from the two parenchymal substrates or in the presence or absence of a pledget. In our experimental model, the Suture-clip, Lapra-Ty, and Horizon clips required significantly greater tension to dislodge than the Hem-o-lok and Endoclip clips. The addition of a pledget did not improve tension resistance.

  10. Single-breath diffusing capacity for carbon monoxide instrument accuracy across 3 health systems.

    PubMed

    Hegewald, Matthew J; Markewitz, Boaz A; Wilson, Emily L; Gallo, Heather M; Jensen, Robert L

    2015-03-01

    Measuring diffusing capacity of the lung for carbon monoxide (DLCO) is complex and associated with wide intra- and inter-laboratory variability. Increased D(LCO) variability may have important clinical consequences. The objective of the study was to assess instrument performance across hospital pulmonary function testing laboratories using a D(LCO) simulator that produces precise and repeatable D(LCO) values. D(LCO) instruments were tested with CO gas concentrations representing medium and high range D(LCO) values. The absolute difference between observed and target D(LCO) value was used to determine measurement accuracy; accuracy was defined as an average deviation from the target value of < 2.0 mL/min/mm Hg. Accuracy of inspired volume measurement and gas sensors were also determined. Twenty-three instruments were tested across 3 healthcare systems. The mean absolute deviation from the target value was 1.80 mL/min/mm Hg (range 0.24-4.23) with 10 of 23 instruments (43%) being inaccurate. High volume laboratories performed better than low volume laboratories, although the difference was not significant. There was no significant difference among the instruments by manufacturers. Inspired volume was not accurate in 48% of devices; mean absolute deviation from target value was 3.7%. Instrument gas analyzers performed adequately in all instruments. D(LCO) instrument accuracy was unacceptable in 43% of devices. Instrument inaccuracy can be primarily attributed to errors in inspired volume measurement and not gas analyzer performance. D(LCO) instrument performance may be improved by regular testing with a simulator. Caution should be used when comparing D(LCO) results reported from different laboratories. Copyright © 2015 by Daedalus Enterprises.

  11. Improving Spleen Volume Estimation via Computer Assisted Segmentation on Clinically Acquired CT Scans

    PubMed Central

    Xu, Zhoubing; Gertz, Adam L.; Burke, Ryan P.; Bansal, Neil; Kang, Hakmook; Landman, Bennett A.; Abramson, Richard G.

    2016-01-01

    OBJECTIVES Multi-atlas fusion is a promising approach for computer-assisted segmentation of anatomical structures. The purpose of this study was to evaluate the accuracy and time efficiency of multi-atlas segmentation for estimating spleen volumes on clinically-acquired CT scans. MATERIALS AND METHODS Under IRB approval, we obtained 294 deidentified (HIPAA-compliant) abdominal CT scans on 78 subjects from a recent clinical trial. We compared five pipelines for obtaining splenic volumes: Pipeline 1–manual segmentation of all scans, Pipeline 2–automated segmentation of all scans, Pipeline 3–automated segmentation of all scans with manual segmentation for outliers on a rudimentary visual quality check, Pipelines 4 and 5–volumes derived from a unidimensional measurement of craniocaudal spleen length and three-dimensional splenic index measurements, respectively. Using Pipeline 1 results as ground truth, the accuracy of Pipelines 2–5 (Dice similarity coefficient [DSC], Pearson correlation, R-squared, and percent and absolute deviation of volume from ground truth) were compared for point estimates of splenic volume and for change in splenic volume over time. Time cost was also compared for Pipelines 1–5. RESULTS Pipeline 3 was dominant in terms of both accuracy and time cost. With a Pearson correlation coefficient of 0.99, average absolute volume deviation 23.7 cm3, and 1 minute per scan, Pipeline 3 yielded the best results. The second-best approach was Pipeline 5, with a Pearson correlation coefficient 0.98, absolute deviation 46.92 cm3, and 1 minute 30 seconds per scan. Manual segmentation (Pipeline 1) required 11 minutes per scan. CONCLUSION A computer-automated segmentation approach with manual correction of outliers generated accurate splenic volumes with reasonable time efficiency. PMID:27519156

  12. Dual-Polarization Observations of Slowly Varying Solar Emissions from a Mobile X-Band Radar

    PubMed Central

    Gabella, Marco; Leuenberger, Andreas

    2017-01-01

    The radio noise that comes from the Sun has been reported in literature as a reference signal to check the quality of dual-polarization weather radar receivers for the S-band and C-band. In most cases, the focus was on relative calibration: horizontal and vertical polarizations were evaluated versus the reference signal mainly in terms of standard deviation of the difference. This means that the investigated radar receivers were able to reproduce the slowly varying component of the microwave signal emitted by the Sun. A novel method, aimed at the absolute calibration of dual-polarization receivers, has recently been presented and applied for the C-band. This method requires the antenna beam axis to be pointed towards the center of the Sun for less than a minute. Standard deviations of the difference as low as 0.1 dB have been found for the Swiss radars. As far as the absolute calibration is concerned, the average differences were of the order of −0.6 dB (after noise subtraction). The method has been implemented on a mobile, X-band radar, and this paper presents the successful results that were obtained during the 2016 field campaign in Payerne (Switzerland). Despite a relatively poor Sun-to-Noise ratio, the “small” (~0.4 dB) amplitude of the slowly varying emission was captured and reproduced; the standard deviation of the difference between the radar and the reference was ~0.2 dB. The absolute calibration of the vertical and horizontal receivers was satisfactory. After the noise subtraction and atmospheric correction a, the mean difference was close to 0 dB. PMID:28531164

  13. Dual-Polarization Observations of Slowly Varying Solar Emissions from a Mobile X-Band Radar.

    PubMed

    Gabella, Marco; Leuenberger, Andreas

    2017-05-22

    The radio noise that comes from the Sun has been reported in literature as a reference signal to check the quality of dual-polarization weather radar receivers for the S-band and C-band. In most cases, the focus was on relative calibration: horizontal and vertical polarizations were evaluated versus the reference signal mainly in terms of standard deviation of the difference. This means that the investigated radar receivers were able to reproduce the slowly varying component of the microwave signal emitted by the Sun. A novel method, aimed at the absolute calibration of dual-polarization receivers, has recently been presented and applied for the C-band. This method requires the antenna beam axis to be pointed towards the center of the Sun for less than a minute. Standard deviations of the difference as low as 0.1 dB have been found for the Swiss radars. As far as the absolute calibration is concerned, the average differences were of the order of -0.6 dB (after noise subtraction). The method has been implemented on a mobile, X-band radar, and this paper presents the successful results that were obtained during the 2016 field campaign in Payerne (Switzerland). Despite a relatively poor Sun-to-Noise ratio, the "small" (~0.4 dB) amplitude of the slowly varying emission was captured and reproduced; the standard deviation of the difference between the radar and the reference was ~0.2 dB. The absolute calibration of the vertical and horizontal receivers was satisfactory. After the noise subtraction and atmospheric correction a, the mean difference was close to 0 dB.

  14. Content-based video retrieval by example video clip

    NASA Astrophysics Data System (ADS)

    Dimitrova, Nevenka; Abdel-Mottaleb, Mohamed

    1997-01-01

    This paper presents a novel approach for video retrieval from a large archive of MPEG or Motion JPEG compressed video clips. We introduce a retrieval algorithm that takes a video clip as a query and searches the database for clips with similar contents. Video clips are characterized by a sequence of representative frame signatures, which are constructed from DC coefficients and motion information (`DC+M' signatures). The similarity between two video clips is determined by using their respective signatures. This method facilitates retrieval of clips for the purpose of video editing, broadcast news retrieval, or copyright violation detection.

  15. Solvation free energies and partition coefficients with the coarse-grained and hybrid all-atom/coarse-grained MARTINI models.

    PubMed

    Genheden, Samuel

    2017-10-01

    We present the estimation of solvation free energies of small solutes in water, n-octanol and hexane using molecular dynamics simulations with two MARTINI models at different resolutions, viz. the coarse-grained (CG) and the hybrid all-atom/coarse-grained (AA/CG) models. From these estimates, we also calculate the water/hexane and water/octanol partition coefficients. More than 150 small, organic molecules were selected from the Minnesota solvation database and parameterized in a semi-automatic fashion. Using either the CG or hybrid AA/CG models, we find considerable deviations between the estimated and experimental solvation free energies in all solvents with mean absolute deviations larger than 10 kJ/mol, although the correlation coefficient is between 0.55 and 0.75 and significant. There is also no difference between the results when using the non-polarizable and polarizable water model, although we identify some improvements when using the polarizable model with the AA/CG solutes. In contrast to the estimated solvation energies, the estimated partition coefficients are generally excellent with both the CG and hybrid AA/CG models, giving mean absolute deviations between 0.67 and 0.90 log units and correlation coefficients larger than 0.85. We analyze the error distribution further and suggest avenues for improvements.

  16. Solvation free energies and partition coefficients with the coarse-grained and hybrid all-atom/coarse-grained MARTINI models

    NASA Astrophysics Data System (ADS)

    Genheden, Samuel

    2017-10-01

    We present the estimation of solvation free energies of small solutes in water, n-octanol and hexane using molecular dynamics simulations with two MARTINI models at different resolutions, viz. the coarse-grained (CG) and the hybrid all-atom/coarse-grained (AA/CG) models. From these estimates, we also calculate the water/hexane and water/octanol partition coefficients. More than 150 small, organic molecules were selected from the Minnesota solvation database and parameterized in a semi-automatic fashion. Using either the CG or hybrid AA/CG models, we find considerable deviations between the estimated and experimental solvation free energies in all solvents with mean absolute deviations larger than 10 kJ/mol, although the correlation coefficient is between 0.55 and 0.75 and significant. There is also no difference between the results when using the non-polarizable and polarizable water model, although we identify some improvements when using the polarizable model with the AA/CG solutes. In contrast to the estimated solvation energies, the estimated partition coefficients are generally excellent with both the CG and hybrid AA/CG models, giving mean absolute deviations between 0.67 and 0.90 log units and correlation coefficients larger than 0.85. We analyze the error distribution further and suggest avenues for improvements.

  17. Interobserver and Intraobserver Agreement on Qualitative Assessments of Right Ventricular Dysfunction With Echocardiography in Patients With Pulmonary Embolism.

    PubMed

    Weekes, Anthony J; Oh, Laura; Thacker, Gregory; Johnson, Angela K; Runyon, Michael; Rose, Geoffrey; Johnson, Thomas; Templin, Megan; Norton, H James

    2016-10-01

    To evaluate observer agreement using qualitative goal-directed echocardiographic criteria for right ventricular (RV) dysfunction prognostication in submassive pulmonary embolism (PE). Two emergency physicians and 2 cardiologists independently reviewed 31 packets of goal-directed echocardiographic video clips consisting of at least 3 windows obtained by emergency physicians from normotensive patients with PE. Nine packets were repeated to assess for intraobserver agreement. Right ventricular dysfunction criteria on goal-directed echocardiography were as follows: RV enlargement was present, with a right-to-left ventricular basal diameter ratio of 1.0 or higher and blunting of the apex of the RV in 2 or more different windows; RV systolic dysfunction was present if the tricuspid annulus moved toward the apex 10 mm or less and there was RV free wall hypokinesis; and septal deviation was present with any flattening or deviation of the ventricular septum toward the left ventricle. Among the 4 participants, there was 83.9% agreement on the presence or absence of RV enlargement (κ = 0.84), 74.2% agreement on the presence or absence of RV systolic dysfunction (κ = 0.69), and 71.0% agreement on the presence or absence of septal deviation (κ = 0.59). Intraobserver agreement was 100% for each RV dysfunction variable for each observer (κ = 1.0). Agreement was substantial for both severe RV enlargement and RV systolic dysfunction and moderate for septal deviation. Right ventricular dysfunction assessment with qualitative goal-directed echocardiographic criteria is reproducible for PE risk stratification.

  18. Discrete distributed strain sensing of intelligent structures

    NASA Technical Reports Server (NTRS)

    Anderson, Mark S.; Crawley, Edward F.

    1992-01-01

    Techniques are developed for the design of discrete highly distributed sensor systems for use in intelligent structures. First the functional requirements for such a system are presented. Discrete spatially averaging strain sensors are then identified as satisfying the functional requirements. A variety of spatial weightings for spatially averaging sensors are examined, and their wave number characteristics are determined. Preferable spatial weightings are identified. Several numerical integration rules used to integrate such sensors in order to determine the global deflection of the structure are discussed. A numerical simulation is conducted using point and rectangular sensors mounted on a cantilevered beam under static loading. Gage factor and sensor position uncertainties are incorporated to assess the absolute error and standard deviation of the error in the estimated tip displacement found by numerically integrating the sensor outputs. An experiment is carried out using a statically loaded cantilevered beam with five point sensors. It is found that in most cases the actual experimental error is within one standard deviation of the absolute error as found in the numerical simulation.

  19. Analytical gradients for subsystem density functional theory within the slater-function-based amsterdam density functional program.

    PubMed

    Schlüns, Danny; Franchini, Mirko; Götz, Andreas W; Neugebauer, Johannes; Jacob, Christoph R; Visscher, Lucas

    2017-02-05

    We present a new implementation of analytical gradients for subsystem density-functional theory (sDFT) and frozen-density embedding (FDE) into the Amsterdam Density Functional program (ADF). The underlying theory and necessary expressions for the implementation are derived and discussed in detail for various FDE and sDFT setups. The parallel implementation is numerically verified and geometry optimizations with different functional combinations (LDA/TF and PW91/PW91K) are conducted and compared to reference data. Our results confirm that sDFT-LDA/TF yields good equilibrium distances for the systems studied here (mean absolute deviation: 0.09 Å) compared to reference wave-function theory results. However, sDFT-PW91/PW91k quite consistently yields smaller equilibrium distances (mean absolute deviation: 0.23 Å). The flexibility of our new implementation is demonstrated for an HCN-trimer test system, for which several different setups are applied. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. Radiologic advantages of potential use of polymer plastic clips in neurosurgery.

    PubMed

    Delibegović, Samir

    2014-01-01

    Plastic clips are made of diamagnetic material and may result in fewer computed tomography (CT) and magnetic resonance artifacts than titanium clips. Considering that polymer plastic clips are increasingly being used in endoscopic surgery, our study examined the CT and magnetic resonance imaging (MRI) characteristics of plastic clips after application in the neurocranium and compared them with titanium clips. Craniotomy was performed on the heads of domestic pigs (Sus scrofa domestica), and, at an angle of 90°, a permanent Yasargil FT 746 T clip was placed in a frontobasal, interhemispheric position. A plastic polymer medium-large Hem-o-lok clip was placed in the same position into another animal. After this procedure, CT of the brain was performed using Siemens 16 slice, followed by an MRI scan, on Philips MRI, 1.5 Tesla. The CT and magnetic resonance scans were analyzed. On axial CT sections through the site of placement of titanium clips, dotted hyperdensity with a high value of Hounsfield units (HUI) of about 2800-3000 could be clearly seen. At the site where the plastic polymer clips were placed, discrete hyperdensity was observed, measuring 130-140 HUI. MRI of the brain in which titanium clips were used revealed a hypointensive T1W signal in the interhemispheric fissure, with a hypointensive T2W signal. On the other hand, upon examination of the MRI of the brain in which plastic clips were used, the T1W signal described above did not occur, and there was also no T2W signal, and no artifacts observed. The plastic clips are made of a diamagnetic, nonconductive material that results in fewer CT and MRI artifacts than titanium clips. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. 21 CFR 878.4320 - Removable skin clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Removable skin clip. 878.4320 Section 878.4320...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a) Identification. A removable skin clip is a clip-like device intended to connect skin tissues temporarily to aid...

  2. Ratings for emotion film clips.

    PubMed

    Gabert-Quillen, Crystal A; Bartolini, Ellen E; Abravanel, Benjamin T; Sanislow, Charles A

    2015-09-01

    Film clips are widely utilized to elicit emotion in a variety of research studies. Normative ratings for scenes selected for these purposes support the idea that selected clips correspond to the intended target emotion, but studies reporting normative ratings are limited. Using an ethnically diverse sample of college undergraduates, selected clips were rated for intensity, discreteness, valence, and arousal. Variables hypothesized to affect the perception of stimuli (i.e., gender, race-ethnicity, and familiarity) were also examined. Our analyses generally indicated that males reacted strongly to positively valenced film clips, whereas females reacted more strongly to negatively valenced film clips. Caucasian participants tended to react more strongly to the film clips, and we found some variation by race-ethnicity across target emotions. Finally, familiarity with the films tended to produce higher ratings for positively valenced film clips, and lower ratings for negatively valenced film clips. These findings provide normative ratings for a useful set of film clips for the study of emotion, and they underscore factors to be considered in research that utilizes scenes from film for emotion elicitation.

  3. Authoring Data-Driven Videos with DataClips.

    PubMed

    Amini, Fereshteh; Riche, Nathalie Henry; Lee, Bongshin; Monroy-Hernandez, Andres; Irani, Pourang

    2017-01-01

    Data videos, or short data-driven motion graphics, are an increasingly popular medium for storytelling. However, creating data videos is difficult as it involves pulling together a unique combination of skills. We introduce DataClips, an authoring tool aimed at lowering the barriers to crafting data videos. DataClips allows non-experts to assemble data-driven "clips" together to form longer sequences. We constructed the library of data clips by analyzing the composition of over 70 data videos produced by reputable sources such as The New York Times and The Guardian. We demonstrate that DataClips can reproduce over 90% of our data videos corpus. We also report on a qualitative study comparing the authoring process and outcome achieved by (1) non-experts using DataClips, and (2) experts using Adobe Illustrator and After Effects to create data-driven clips. Results indicated that non-experts are able to learn and use DataClips with a short training period. In the span of one hour, they were able to produce more videos than experts using a professional editing tool, and their clips were rated similarly by an independent audience.

  4. Proposal for a CLIPS software library

    NASA Technical Reports Server (NTRS)

    Porter, Ken

    1991-01-01

    This paper is a proposal to create a software library for the C Language Integrated Production System (CLIPS) expert system shell developed by NASA. Many innovative ideas for extending CLIPS were presented at the First CLIPS Users Conference, including useful user and database interfaces. CLIPS developers would benefit from a software library of reusable code. The CLIPS Users Group should establish a software library-- a course of action to make that happen is proposed. Open discussion to revise this library concept is essential, since only a group effort is likely to succeed. A response form intended to solicit opinions and support from the CLIPS community is included.

  5. Biocompatibility of Plastic Clip in Neurocranium - Experimental Study on Dogs.

    PubMed

    Delibegovic, Samir; Dizdarevic, Kemal; Cickusic, Elmir; Katica, Muhamed; Obhodjas, Muamer; Ocus, Muhamed

    2016-01-01

    A potential advantage of the use of the plastic clips in neurosurgery is their property of causing fewer artifacts than titanium clips as assessed by computed tomography and magnetic resonance scans. The biocompatibility of plastic clips was demonstrated in the peritoneal cavity, but their behavior in the neurocranium is not known. Twelve aggressive stray dogs designated for euthanasia were taken for this experimental study. The animals were divided into two groups. In all cases, after anesthesia, a craniotomy was performed, and after opening the dura, a proximal part titanium clip was placed on the isolated superficial Sylvian vein (a permanent Yasargil FT 746 T clip at a 90° angle, while a plastic Hem-o-lok clip ML was placed on another part of the vein). The first group of animals was sacrificed on the 7 < sup > th < /sup > postoperative day and the second group on the 60 < sup > th < /sup > postoperative day. Samples of tissue around the clips were taken for a histopathological evaluation. The plastic clip caused a more intensive tissue reaction than the titanium clip on the 7 < sup > th < /sup > postoperative day, but there was no statistical difference. Even on the 60 < sup > th < /sup > postoperative day there was no significant difference in tissue reaction between the titanium and plastic clips. These preliminary results confirm the possibility for the use of plastic clips in neurosurgery. Before their use in human neurosurgery, further studies are needed to investigate the long-term effects of the presence of plastic clips in the neurocranium, as well as studies of the aneurysmal model.

  6. Fuzzy expert systems using CLIPS

    NASA Technical Reports Server (NTRS)

    Le, Thach C.

    1994-01-01

    This paper describes a CLIPS-based fuzzy expert system development environment called FCLIPS and illustrates its application to the simulated cart-pole balancing problem. FCLIPS is a straightforward extension of CLIPS without any alteration to the CLIPS internal structures. It makes use of the object-oriented and module features in CLIPS version 6.0 for the implementation of fuzzy logic concepts. Systems of varying degrees of mixed Boolean and fuzzy rules can be implemented in CLIPS. Design and implementation issues of FCLIPS will also be discussed.

  7. Dosimetric Evaluation of Metal Artefact Reduction using Metal Artefact Reduction (MAR) Algorithm and Dual-energy Computed Tomography (CT) Method

    NASA Astrophysics Data System (ADS)

    Laguda, Edcer Jerecho

    Purpose: Computed Tomography (CT) is one of the standard diagnostic imaging modalities for the evaluation of a patient's medical condition. In comparison to other imaging modalities such as Magnetic Resonance Imaging (MRI), CT is a fast acquisition imaging device with higher spatial resolution and higher contrast-to-noise ratio (CNR) for bony structures. CT images are presented through a gray scale of independent values in Hounsfield units (HU). High HU-valued materials represent higher density. High density materials, such as metal, tend to erroneously increase the HU values around it due to reconstruction software limitations. This problem of increased HU values due to metal presence is referred to as metal artefacts. Hip prostheses, dental fillings, aneurysm clips, and spinal clips are a few examples of metal objects that are of clinical relevance. These implants create artefacts such as beam hardening and photon starvation that distort CT images and degrade image quality. This is of great significance because the distortions may cause improper evaluation of images and inaccurate dose calculation in the treatment planning system. Different algorithms are being developed to reduce these artefacts for better image quality for both diagnostic and therapeutic purposes. However, very limited information is available about the effect of artefact correction on dose calculation accuracy. This research study evaluates the dosimetric effect of metal artefact reduction algorithms on severe artefacts on CT images. This study uses Gemstone Spectral Imaging (GSI)-based MAR algorithm, projection-based Metal Artefact Reduction (MAR) algorithm, and the Dual-Energy method. Materials and Methods: The Gemstone Spectral Imaging (GSI)-based and SMART Metal Artefact Reduction (MAR) algorithms are metal artefact reduction protocols embedded in two different CT scanner models by General Electric (GE), and the Dual-Energy Imaging Method was developed at Duke University. All three approaches were applied in this research for dosimetric evaluation on CT images with severe metal artefacts. The first part of the research used a water phantom with four iodine syringes. Two sets of plans, multi-arc plans and single-arc plans, using the Volumetric Modulated Arc therapy (VMAT) technique were designed to avoid or minimize influences from high-density objects. The second part of the research used projection-based MAR Algorithm and the Dual-Energy Method. Calculated Doses (Mean, Minimum, and Maximum Doses) to the planning treatment volume (PTV) were compared and homogeneity index (HI) calculated. Results: (1) Without the GSI-based MAR application, a percent error between mean dose and the absolute dose ranging from 3.4-5.7% per fraction was observed. In contrast, the error was decreased to a range of 0.09-2.3% per fraction with the GSI-based MAR algorithm. There was a percent difference ranging from 1.7-4.2% per fraction between with and without using the GSI-based MAR algorithm. (2) A range of 0.1-3.2% difference was observed for the maximum dose values, 1.5-10.4% for minimum dose difference, and 1.4-1.7% difference on the mean doses. Homogeneity indexes (HI) ranging from 0.068-0.065 for dual-energy method and 0.063-0.141 with projection-based MAR algorithm were also calculated. Conclusion: (1) Percent error without using the GSI-based MAR algorithm may deviate as high as 5.7%. This error invalidates the goal of Radiation Therapy to provide a more precise treatment. Thus, GSI-based MAR algorithm was desirable due to its better dose calculation accuracy. (2) Based on direct numerical observation, there was no apparent deviation between the mean doses of different techniques but deviation was evident on the maximum and minimum doses. The HI for the dual-energy method almost achieved the desirable null values. In conclusion, the Dual-Energy method gave better dose calculation accuracy to the planning treatment volume (PTV) for images with metal artefacts than with or without GE MAR Algorithm.

  8. Restoration of clipped seismic waveforms using projection onto convex sets method

    PubMed Central

    Zhang, Jinhai; Hao, Jinlai; Zhao, Xu; Wang, Shuqin; Zhao, Lianfeng; Wang, Weimin; Yao, Zhenxing

    2016-01-01

    The seismic waveforms would be clipped when the amplitude exceeds the upper-limit dynamic range of seismometer. Clipped waveforms are typically assumed not useful and seldom used in waveform-based research. Here, we assume the clipped components of the waveform share the same frequency content with the un-clipped components. We leverage this similarity to convert clipped waveforms to true waveforms by iteratively reconstructing the frequency spectrum using the projection onto convex sets method. Using artificially clipped data we find that statistically the restoration error is ~1% and ~5% when clipped at 70% and 40% peak amplitude, respectively. We verify our method using real data recorded at co-located seismometers that have different gain controls, one set to record large amplitudes on scale and the other set to record low amplitudes on scale. Using our restoration method we recover 87 out of 93 clipped broadband records from the 2013 Mw6.6 Lushan earthquake. Estimating that we recover 20 clipped waveforms for each M5.0+ earthquake, so for the ~1,500 M5.0+ events that occur each year we could restore ~30,000 clipped waveforms each year, which would greatly enhance useable waveform data archives. These restored waveform data would also improve the azimuthal station coverage and spatial footprint. PMID:27966618

  9. A systematic review of discomfort due to toe or ear clipping in laboratory rodents

    PubMed Central

    Geessink, Florentine J.; Brouwer, Michelle A. E.; Tillema, Alice; Ritskes-Hoitinga, Merel

    2017-01-01

    Toe clipping and ear clipping (also ear notching or ear punching) are frequently used methods for individual identification of laboratory rodents. These procedures potentially cause severe discomfort, which can reduce animal welfare and distort experimental results. However, no systematic summary of the evidence on this topic currently exists. We conducted a systematic review of the evidence for discomfort due to toe or ear clipping in rodents. The review methodology was pre-specified in a registered review protocol. The population, intervention, control, outcome (PICO) question was: In rodents, what is the effect of toe clipping or ear clipping, compared with no clipping or sham clipping, on welfare-related outcomes? Through a systematic search in PubMed, Embase, Web of Science and grey literature, we identified seven studies on the effect of ear clipping on animal welfare, and five such studies on toe clipping. Studies were included in the review if they contained original data from an in vivo experiment in rodents, assessing the effect of toe clipping or ear clipping on a welfare-related outcome. Case studies and studies applying unsuitable co-interventions were excluded. Study quality was appraised using an extended version of SYstematic Review Centre for Laboratory animal Experimentation (SYRCLE)’s risk of bias tool for animal studies. Study characteristics and outcome measures were highly heterogeneous, and there was an unclear or high risk of bias in all studies. We therefore present a narrative synthesis of the evidence identified. None of the studies reported a sample size calculation. Out of over 60 different outcomes, we found evidence of discomfort due to ear clipping in the form of increased respiratory volume, vocalization and blood pressure. For toe clipping, increased vocalization and decreased motor activity in pups were found, as well as long-term effects in the form of reduced grip strength and swimming ability in adults. In conclusion, there is too little evidence to reliably assess discomfort due to toe or ear clipping, and the quality of the available evidence is uncertain. Adequately powered, high-quality studies reporting reliable, relevant outcome measures are needed to accurately assess the impact of these identification techniques. Until more reliable evidence is available, any effect of toe clipping or ear clipping on animal welfare and study results cannot be confirmed or excluded. PMID:28429644

  10. Taxonomic and Functional Responses of Soil Microbial Communities to Annual Removal of Aboveground Plant Biomass

    PubMed Central

    Guo, Xue; Zhou, Xishu; Hale, Lauren; Yuan, Mengting; Feng, Jiajie; Ning, Daliang; Shi, Zhou; Qin, Yujia; Liu, Feifei; Wu, Liyou; He, Zhili; Van Nostrand, Joy D.; Liu, Xueduan; Luo, Yiqi; Tiedje, James M.; Zhou, Jizhong

    2018-01-01

    Clipping, removal of aboveground plant biomass, is an important issue in grassland ecology. However, few studies have focused on the effect of clipping on belowground microbial communities. Using integrated metagenomic technologies, we examined the taxonomic and functional responses of soil microbial communities to annual clipping (2010–2014) in a grassland ecosystem of the Great Plains of North America. Our results indicated that clipping significantly (P < 0.05) increased root and microbial respiration rates. Annual temporal variation within the microbial communities was much greater than the significant changes introduced by clipping, but cumulative effects of clipping were still observed in the long-term scale. The abundances of some bacterial and fungal lineages including Actinobacteria and Bacteroidetes were significantly (P < 0.05) changed by clipping. Clipping significantly (P < 0.05) increased the abundances of labile carbon (C) degrading genes. More importantly, the abundances of recalcitrant C degrading genes were consistently and significantly (P < 0.05) increased by clipping in the last 2 years, which could accelerate recalcitrant C degradation and weaken long-term soil carbon stability. Furthermore, genes involved in nutrient-cycling processes including nitrogen cycling and phosphorus utilization were also significantly increased by clipping. The shifts of microbial communities were significantly correlated with soil respiration and plant productivity. Intriguingly, clipping effects on microbial function may be highly regulated by precipitation at the interannual scale. Altogether, our results illustrated the potential of soil microbial communities for increased soil organic matter decomposition under clipping land-use practices. PMID:29904372

  11. It is time for a better clip applier - 3 mm, percutaneous, non-crushing and locking.

    PubMed

    Yuval, Jonathan B; Weiss, Daniel J; Paz, Adrian; Bachar, Yehuda; Brodie, Ronit; Shapira, Yinon; Mintz, Yoav

    2017-10-06

    Since the advent of laparoscopy there have been attempts to minimize abdominal wall incisions. For this purpose smaller instruments have been produced. Our aim was to develop the first 3 mm percutaneous clip applier and to make it better than the standard clips of today. The ClipTip clip is made of Nitinol and has a crocodile shaped jaws, which when apposed effectively seal vessels. The shaft operates as a retractable needle permitting percutaneous insertion. Closing, reopening and reclosing is possible. The physical properties of the device were compared to three commercially available clip appliers. Surgeries were performed on porcine animals by experienced surgeons. In comparison to available clips, the superiority of the ClipTip is a combination of wide effective length alongside the ability to withstand strong forces. In live animal studies the Cliptip was inserted into the peritoneal cavity without any injuries. Vessels were ligated successfully and no clip dislodgement or leakage occurred. We developed the next generation clip applier with better properties. Advantages include its length, the needleoscopic caliber, non-crushing effect, locking mechanism and wide aperture. The device has performed safely and effectively in pre-clinical tests. Further studies are planned in humans.

  12. Persistence in and Release of 2,4-D and Azoxystrobin from Turfgrass Clippings.

    PubMed

    Jeffries, Matthew D; Yelverton, Fred H; Ahmed, Khalied A; Gannon, Travis W

    2016-11-01

    Research has shown that pesticide residue in clippings from previously treated turfgrass may become bioavailable as grass decomposes, adversely affecting off-target organisms. We conducted a field study to quantify 2,4-D (2,4-dichlorophenoxyacetic acid) and azoxystrobin (methyl(E)-2-{2[6-(2-cyanophenoxy)pyrmidin-4-yloxy]phenyl}-3-methoxyacrylate) residues in turfgrass clippings collected from hybrid bermudagrass [ (L.) Pers. × Burtt-Davy], tall fescue [ (Schreb.) S.J. Darbyshire], and zoysiagrass ( Steud.). A subsequent greenhouse experiment was conducted to measure pesticide release from clippings into water. 2,4-D (1.6 kg a.i. ha) and azoxystrobin (0.6 kg a.i. ha) were applied to field plots at 32, 16, 8, 4, 2, 1, or 0 d before collection of the clippings. Clippings were collected from each experimental unit to quantify pesticide release from clippings into water. Both 2,4-D and azoxystrobin were detected when turfgrass was treated over the 32-d experimental period, suggesting that clipping management should be implemented for an extended period of time after application. Pesticide residue was detected in all water samples collected, confirming 2,4-D and azoxystrobin release from turfgrass clippings; however, pesticide release varied between compounds. Two days after clippings were incorporated in water, 39 and 10% of 2,4-D and azoxystrobin were released from clippings, respectively. Our research supports the currently recommended practice of returning clippings to the turfgrass stand when mowing because removal of 2,4-D and azoxystrobin in clippings may reduce pest control and cause adverse off-target impacts. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  13. The efficiency of the new Yasargil titanium fenestrated mini-clips for ideal clipping of a cerebral aneurysm

    PubMed Central

    Ota, Nakao; Tanikawa, Rokuya; Noda, Kosumo; Tsuboi, Toshiyuki; Kamiyama, Hiroyasu; Tokuda, Sadahisa

    2015-01-01

    Background: The fenestrated clip is sometimes useful in limited approach angle and narrow working space. However, before the development of the new Yasargil titanium fenestrated mini-clip, the only variations of fenestrated clips were those of larger sizes. And those larger clips have a problem of the triangle-shaped gap at the proximal end of the blade. The authors describe the efficiency, limitations and surgical technique of using the Yasargil titanium fenestrated mini-clip. Methods: Fifty-nine cases of aneurysms were treated using these mini-clips. Aneurysm location, size and dome neck ratio, mean follow-up period, neck remnant, and recurrence rate were also analyzed. Among these cases, we present eight characteristic cases, including a case with aneurysm recurrence, and we review the problems associated with the triangle-shaped gap at the proximal end of the clip. Results: The average size of the aneurysms was 5.57 mm, and the dome neck ratio was >2.0 in 1.69%, >1.5 in 11.8%, >1.2 in 35.6%, and <1.2 in 50.8% of cases. The mean follow-up period for the 59 cases was 5.5 months (range, 0.5–16 months). Angiographic recurrence of the treated portion occurred in 1 case (1.7%), including an aneurysm in the basilar artery tip aneurysm. Conclusion: The availability of the Yasargil titanium fenestrated mini-clip increases the options for clipping to minimize the remnant of the clipped aneurysm. However, there is still concern over the triangular space at the base of the blade, especially when treating an aneurysm with a thin vessel wall. Therefore, modification of the clipping technique is sometimes needed. PMID:26664871

  14. Measuring (subglacial) bedform orientation, length, and longitudinal asymmetry - Method assessment.

    PubMed

    Jorge, Marco G; Brennand, Tracy A

    2017-01-01

    Geospatial analysis software provides a range of tools that can be used to measure landform morphometry. Often, a metric can be computed with different techniques that may give different results. This study is an assessment of 5 different methods for measuring longitudinal, or streamlined, subglacial bedform morphometry: orientation, length and longitudinal asymmetry, all of which require defining a longitudinal axis. The methods use the standard deviational ellipse (not previously applied in this context), the longest straight line fitting inside the bedform footprint (2 approaches), the minimum-size footprint-bounding rectangle, and Euler's approximation. We assess how well these methods replicate morphometric data derived from a manually mapped (visually interpreted) longitudinal axis, which, though subjective, is the most typically used reference. A dataset of 100 subglacial bedforms covering the size and shape range of those in the Puget Lowland, Washington, USA is used. For bedforms with elongation > 5, deviations from the reference values are negligible for all methods but Euler's approximation (length). For bedforms with elongation < 5, most methods had small mean absolute error (MAE) and median absolute deviation (MAD) for all morphometrics and thus can be confidently used to characterize the central tendencies of their distributions. However, some methods are better than others. The least precise methods are the ones based on the longest straight line and Euler's approximation; using these for statistical dispersion analysis is discouraged. Because the standard deviational ellipse method is relatively shape invariant and closely replicates the reference values, it is the recommended method. Speculatively, this study may also apply to negative-relief, and fluvial and aeolian bedforms.

  15. Volume Quantification of Acute Infratentorial Hemorrhage with Computed Tomography: Validation of the Formula 1/2ABC and 2/3SH

    PubMed Central

    Zhang, Yunyun; Yan, Jing; Fu, Yi; Chen, Shengdi

    2013-01-01

    Objective To compare the accuracy of formula 1/2ABC with 2/3SH on volume estimation for hypertensive infratentorial hematoma. Methods One hundred and forty-seven CT scans diagnosed as hypertensive infratentorial hemorrhage were reviewed. Based on the shape, hematomas were categorized as regular or irregular. Multilobular was defined as a special shape of irregular. Hematoma volume was calculated employing computer-assisted volumetric analysis (CAVA), 1/2ABC and 2/3SH, respectively. Results The correlation coefficients between 1/2ABC (or 2/3SH) and CAVA were greater than 0.900 in all subgroups. There were neither significant differences in absolute values of volume deviation nor percentage deviation between 1/2ABC and 2/3SH for regular hemorrhage (P>0.05). While for cerebellar, brainstem and irregular hemorrhages, the absolute values of volume deviation and percentage deviation by formula 1/2ABC were greater than 2/3SH (P<0.05). 1/2ABC and 2/3SH underestimated hematoma volume each by 10% and 5% for cerebellar hemorrhage, 14% and 9% for brainstem hemorrhage, 19% and 16% for regular hemorrhage, 9% and 3% for irregular hemorrhage, respectively. In addition, for the multilobular hemorrhage, 1/2ABC underestimated the volume by 9% while 2/3SH overestimated it by 2%. Conclusions For regular hemorrhage volume calculation, the accuracy of 2/3SH is similar to 1/2ABC. While for cerebellar, brainstem or irregular hemorrhages (including multilobular), 2/3SH is more accurate than 1/2ABC. PMID:23638025

  16. SMOQ: a tool for predicting the absolute residue-specific quality of a single protein model with support vector machines

    PubMed Central

    2014-01-01

    Background It is important to predict the quality of a protein structural model before its native structure is known. The method that can predict the absolute local quality of individual residues in a single protein model is rare, yet particularly needed for using, ranking and refining protein models. Results We developed a machine learning tool (SMOQ) that can predict the distance deviation of each residue in a single protein model. SMOQ uses support vector machines (SVM) with protein sequence and structural features (i.e. basic feature set), including amino acid sequence, secondary structures, solvent accessibilities, and residue-residue contacts to make predictions. We also trained a SVM model with two new additional features (profiles and SOV scores) on 20 CASP8 targets and found that including them can only improve the performance when real deviations between native and model are higher than 5Å. The SMOQ tool finally released uses the basic feature set trained on 85 CASP8 targets. Moreover, SMOQ implemented a way to convert predicted local quality scores into a global quality score. SMOQ was tested on the 84 CASP9 single-domain targets. The average difference between the residue-specific distance deviation predicted by our method and the actual distance deviation on the test data is 2.637Å. The global quality prediction accuracy of the tool is comparable to other good tools on the same benchmark. Conclusion SMOQ is a useful tool for protein single model quality assessment. Its source code and executable are available at: http://sysbio.rnet.missouri.edu/multicom_toolbox/. PMID:24776231

  17. SMOQ: a tool for predicting the absolute residue-specific quality of a single protein model with support vector machines.

    PubMed

    Cao, Renzhi; Wang, Zheng; Wang, Yiheng; Cheng, Jianlin

    2014-04-28

    It is important to predict the quality of a protein structural model before its native structure is known. The method that can predict the absolute local quality of individual residues in a single protein model is rare, yet particularly needed for using, ranking and refining protein models. We developed a machine learning tool (SMOQ) that can predict the distance deviation of each residue in a single protein model. SMOQ uses support vector machines (SVM) with protein sequence and structural features (i.e. basic feature set), including amino acid sequence, secondary structures, solvent accessibilities, and residue-residue contacts to make predictions. We also trained a SVM model with two new additional features (profiles and SOV scores) on 20 CASP8 targets and found that including them can only improve the performance when real deviations between native and model are higher than 5Å. The SMOQ tool finally released uses the basic feature set trained on 85 CASP8 targets. Moreover, SMOQ implemented a way to convert predicted local quality scores into a global quality score. SMOQ was tested on the 84 CASP9 single-domain targets. The average difference between the residue-specific distance deviation predicted by our method and the actual distance deviation on the test data is 2.637Å. The global quality prediction accuracy of the tool is comparable to other good tools on the same benchmark. SMOQ is a useful tool for protein single model quality assessment. Its source code and executable are available at: http://sysbio.rnet.missouri.edu/multicom_toolbox/.

  18. SU-E-J-201: Position Verification in Breast Cancer Radiotherapy Using Tantalum Clips in the Lumpectomy Cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santvoort, J van; Van der Drift, M; Kuipers, J

    2014-06-01

    Purpose: To find out whether tantalum surgical clips can be used for online position verification in treatment of the lumpectomy cavity (LC) in breast cancer patients. Tantalum is a high density metal that could be visible on Electronic Portal Images (EPIs) and be an affordable alternative to gold markers. Clips are considered more representative for the LC position than nearby bony structures. Methods: In twelve patients the surgeon had placed 2 to 5 tantalum clips in the LC. The AP and lateral fields used for portal imaging, were adapted. In doing so, both bony structures and tantalum clips were visiblemore » on EPIs. The following analyses were performed:1. Image degradation, with respect to delineating the CTV, of the axial CT slices by artefacts because of the tantalum clips was evaluated by a radiation oncologist;2. The visibility of the tantalum clips on the EPIs was evaluated by four radiation therapists (RTTs);3. Bony anatomy and tantalum clip matches were performed on the same images independently by two observers. Results: 1. Delineation of the CTV by the radiation oncologist was not hampered by CT image artefacts because of the clips.2. The mean score for visibility of the clips on the EPIs, analysed by the four RTTs, was 5.6 on a scale of 10 (range 3.9 – 8.0).3. In total 12 patients with 16 fractions each were analysed. The differences between clip match and bone match are significant with a mean vector length of 5.2 mm (SD 1.9 mm) for the difference. Conclusion: Results of matches on tantalum clips as compared to matches on bony structures differ substantially. Therefore clip matches can result in smaller CTV to PTV margins than bone matches. Visibility of the clips on EPIs is sufficient, so they can be an alternative to gold markers.« less

  19. Laparoscopic sterilization with the spring clip: instrumentation development and current clinical experience.

    PubMed

    Hulka, J F; Omran, K; Lieberman, B A; Gordon, A G

    1979-12-15

    Since the original spring clip sterilization studies were reported, a number of clinically important modifications to the spring clip and applicator have been developed. The spring-loaded clip, manufactured by Richard Wolf Medical Instruments Corporation of Chicago, Illinois, and Rocket of London, Inc., London, England, and New York, New York can be applied with either a one- or two-incision applicator and the clips and applicators currently available incorporate improvements to the original prototypes in design, manufacture, and quality control. The two-incision applicator is associated with significantly fewer misapplications and the high pregnancy rates reported with the original clip and applicator have not occurred with the current designs. Comparative studies between the clip and band have revealed less operative bleeding and pain associated with the clip. The method is appropriate to all women requesting sterilization but especially to those in the younger age group who may subsequently request reversal because of divorce and remarriage.

  20. Validation of ozone intensities at 10 μm with THz spectrometry

    NASA Astrophysics Data System (ADS)

    Drouin, Brian J.; Crawford, Timothy J.; Yu, Shanshan

    2017-12-01

    This manuscript reports an effort to improve the absolute accuracy of ozone intensities in the 10 μm region via a transfer of the precision of the rotational dipole moment onto the infrared measurement. The approach determines the ozone mixing ratio through alternately measuring seven pure rotation ozone lines from 692 to 779 GHz. A multispectrum fitting technique was employed. The results determine the column with absolute accuracy of 1.5% and the intensities of infrared transitions measured at this accuracy reproduce the recommended values to within a standard deviation of 2.8%.

  1. An object oriented extension to CLIPS

    NASA Technical Reports Server (NTRS)

    Sobkowicz, Clifford

    1990-01-01

    A presentation of software sub-system developed to augment C Language Production Systems (CLIPS) with facilities for object oriented Knowledge representation. Functions are provided to define classes, instantiate objects, access attributes, and assert object related facts. This extension is implemented via the CLIPS user function interface and does not require modification of any CLIPS code. It does rely on internal CLIPS functions for memory management and symbol representation.

  2. Utility of nonpenetrating titanium clips for dural closure during spinal surgery to prevent postoperative cerebrospinal fluid leakage.

    PubMed

    Ito, Kiyoshi; Aoyama, Tatsuro; Horiuchi, Tetsuyoshi; Hongo, Kazuhiro

    2015-12-01

    The nonpenetrating titanium clip has been successfully used in peripheral arterial bypass surgery. The purpose of this study was to evaluate the leakage pressures and patterns of nonpenetrating titanium clips using a simple model that mimicked spinal surgery. In addition, the authors describe their surgical experience with these clips and the follow-up results in 31 consecutive patients. The authors compared nonpenetrating titanium clips and expanded polytetrafluoroethylene (ePTFE) sutures in relation to the water pressure that could be tolerated by sutured ePTFE sheets, and the leakage pressure patterns were determined. The changes in leakage pressures at 5 minutes, 30 minutes, and 12 hours were examined when the clips and sutures were used in combination with the mesh-and-glue technique in an in vitro study. Thirty-one patients underwent spinal intradural procedures using nonpenetrating titanium clips to suture the dura maters using the meshand-glue technique, involving fibrin glue and polyglycolic acid-fibrin sheets. A significant difference was apparent between the ePTFE suture group and the nonpenetrating titanium clip group, with the latter showing a leakage pressure that could be sustained and was 1508% higher than that of the former (p = 0.001). In relation to leakage patterns, the nonpenetrating titanium clips did not make any suture holes in the ePTFE sheet and fluid leakage occurred between the clips, whereas fluid leakage was associated with the pressure elevation that occurred at the suture holes made by the ePTFE sutures. Of the 31 patients who underwent spinal intradural procedures using nonpenetrating titanium clips, 1 (3.2%) experienced cerebrospinal fluid (CSF) leakage postoperatively. No other complications-for example, allergic reactions, adhesions, or infections--were encountered. The interrupted placement of nonpenetrating titanium clips enables dural closure without creating any holes. These clips facilitate improvements in the initial leakage pressure and reduce postoperative CSF leakage following spinal surgery. The authors conclude that it is very beneficial to suture the spinal dura mater using nonpenetrating titanium clips given the anatomical characteristics of the spinal dura mater and the fact that the clips do not create suture holes.

  3. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    PubMed

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  4. Using CLIPS as the cornerstone of a graduate expert systems course

    NASA Technical Reports Server (NTRS)

    Yue, Kwok-Bun

    1991-01-01

    The effective use of the C Language Integrated Production System (CLIPS) as a cornerstone in a graduate expert systems course is described. The course include 8 or 9 hours of in-depth lecturing in CLIPS, as well as a broad coverage of major topics and techniques in expert systems. As part of the requirements of the course, students solved two small yet non-trival problems in CLIPS before going on to develop a toy expert system in CLIPS in an incremental manner as the term project. Furthermore, students were required to evaluate CLIPS programs written by their classmates. An anonymous questionnaire at the end of the semester revealed that the students responded very favorably to the course, especially their experience with CLIPS.

  5. Third CLIPS Conference Proceedings, volume 2

    NASA Technical Reports Server (NTRS)

    Riley, Gary (Editor)

    1994-01-01

    Expert systems are computer programs which emulate human expertise in well defined problem domains. The C Language Integrated Production System (CLIPS) is an expert system building tool, developed at the Johnson Space Center, which provides a complete environment for the development and delivery of rule and/or object based expert systems. CLIPS was specifically designed to provide a low cost option for developing and deploying expert system applications across a wide range of hardware platforms. The development of CLIPS has helped to improve the ability to deliver expert system technology throughout the public and private sectors for a wide range of applications and diverse computing environments. The Third Conference on CLIPS provided a forum for CLIPS users to present and discuss papers relating to CLIPS applications, uses, and extensions.

  6. MIRO: A debugging tool for CLIPS incorporating historical Rete networks

    NASA Technical Reports Server (NTRS)

    Tuttle, Sharon M.; Eick, Christoph F.

    1994-01-01

    At the last CLIPS conference, we discussed our ideas for adding a temporal dimension to the Rete network used to implement CLIPS. The resulting historical Rete network could then be used to store 'historical' information about a run of a CLIPS program, to aid in debugging. MIRO, a debugging tool for CLIPS built on top of CLIPS, incorporates such a historical Rete network and uses it to support its prototype question-answering capability. By enabling CLIPS users to directly ask debugging-related questions about the history of a program run, we hope to reduce the amount of single-stepping and program tracing required to debug a CLIPS program. In this paper, we briefly describe MIRO's architecture and implementation, and the current question-types that MIRO supports. These question-types are further illustrated using an example, and the benefits of the debugging tool are discussed. We also present empirical results that measure the run-time and partial storage overhead of MIRO, and discuss how MIRO may also be used to study various efficiency aspects of CLIPS programs.

  7. Alpha-actinin-3 (ACTN3) R577X polymorphism influences knee extensor peak power response to strength training in older men and women.

    PubMed

    Delmonico, Matthew J; Kostek, Matthew C; Doldo, Neil A; Hand, Brian D; Walsh, Sean; Conway, Joan M; Carignan, Craig R; Roth, Stephen M; Hurley, Ben F

    2007-02-01

    The alpha-actinin-3 (ACTN3) R577X polymorphism has been associated with muscle power performance in cross-sectional studies. We examined baseline knee extensor concentric peak power (PP) and PP change with approximately 10 weeks of unilateral knee extensor strength training (ST) using air-powered resistance machines in 71 older men (65 [standard deviation = 8] years) and 86 older women (64 [standard deviation = 9] years). At baseline in women, the XX genotype group had an absolute (same resistance) PP that was higher than the RR (p =.005) and RX genotype groups (p =.02). The women XX group also had a relative (70% of one-repetition maximum [1-RM]) PP that was higher than that in the RR (p =.002) and RX groups (p =.008). No differences in baseline absolute or relative PP were observed between ACTN3 genotype groups in men. In men, absolute PP change with ST in the RR (n = 16) group approached a significantly higher value than in the XX group (n = 9; p =.07). In women, relative PP change with ST in the RR group (n = 16) was higher than in the XX group (n = 17; p =.02). The results indicate that the ACTN3 R577X polymorphism influences the response of quadriceps muscle power to ST in older adults.

  8. The disappearing clip: an unusual complication in MRI biopsy

    PubMed Central

    Bourke, Anita Geraldine; Peter, Prasant; Jose, Chaitra Lesli

    2014-01-01

    MRI-guided biopsies are being increasingly used for otherwise occult breast lesions. Clip migration has been reported however, to the best of our knowledge, there have been no documented cases of entire disappearance of a marker clip. Absence of the postbiopsy marker clip was noted when our patient returned for preoperative hook-wire localisation even though accurate clip placement had been confirmed on the post-MRI biopsy mammogram. PMID:25139917

  9. Using film clips to enhance nursing education.

    PubMed

    Herrman, Judith W

    2006-01-01

    Film clips in nursing education provide a unique way to promote active learning. Several methods for using film clips and combining them with other teaching strategies are discussed. Suggestions for the use of popular clips, logistical aspects of showing clips in class, and legal issues associated with copyright are addressed. Faculty are encouraged to use this strategy to evoke emotional responses, generate discussion, enhance clinical decision making, and provide vicarious learning.

  10. Comparison of Intraoperative Indocyanine Green Angiography and Digital Subtraction Angiography for Clipping of Intracranial Aneurysms

    PubMed Central

    Doss, Vinodh T.; Goyal, Nitin; Humphries, William; Hoit, Dan; Arthur, Adam; Elijovich, Lucas

    2015-01-01

    Background Residual aneurysm after microsurgical clipping carries a risk of aneurysm growth and rupture. Digital subtraction angiography (DSA) remains the standard to determine the adequacy of clipping. Intraoperative indocyanine green (ICG) angiography is increasingly utilized to confirm optimal clip positioning across the neck and to evaluate the adjacent vasculature. Objective We evaluated the correlation between ICG and DSA in clipped intracranial aneurysms. Methods A retrospective study of patients who underwent craniotomy and microsurgical clipping of intracranial aneurysms with ICG for 2 years. Patient characteristics, presentation details, operative reports, and pre- and postclipping angiographic images were reviewed to determine the adequacy of the clipping. Results Forty-seven patients underwent clipping with ICG and postoperative DSA: 57 aneurysms were clipped; 23 patients (48.9%) presented with subarachnoid hemorrhage. Nine aneurysms demonstrated a residual on DSA not identified on ICG (residual sizes ranged from 0.5 to 4.3 mm; average size: 1.8 mm). Postoperative DSA demonstrated no branch occlusions. Conclusion Intraoperative ICG is useful in the clipping of intracranial aneurysms to ensure a gross patency of branch vessels; however, the presence of residual aneurysms and subtle changes in flow in branch vessels is best seen by DSA. This has important clinical implications with regard to follow-up imaging and surgical/endovascular management. PMID:26279659

  11. Note: An absolute X-Y-Θ position sensor using a two-dimensional phase-encoded binary scale

    NASA Astrophysics Data System (ADS)

    Kim, Jong-Ahn; Kim, Jae Wan; Kang, Chu-Shik; Jin, Jonghan

    2018-04-01

    This Note presents a new absolute X-Y-Θ position sensor for measuring planar motion of a precision multi-axis stage system. By analyzing the rotated image of a two-dimensional phase-encoded binary scale (2D), the absolute 2D position values at two separated points were obtained and the absolute X-Y-Θ position could be calculated combining these values. The sensor head was constructed using a board-level camera, a light-emitting diode light source, an imaging lens, and a cube beam-splitter. To obtain the uniform intensity profiles from the vignette scale image, we selected the averaging directions deliberately, and higher resolution in the angle measurement could be achieved by increasing the allowable offset size. The performance of a prototype sensor was evaluated in respect of resolution, nonlinearity, and repeatability. The sensor could resolve 25 nm linear and 0.001° angular displacements clearly, and the standard deviations were less than 18 nm when 2D grid positions were measured repeatedly.

  12. Sex Differences in Emotional Evaluation of Film Clips: Interaction with Five High Arousal Emotional Categories.

    PubMed

    Maffei, Antonio; Vencato, Valentina; Angrilli, Alessandro

    2015-01-01

    The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives.

  13. Recurrence of ICA-PCoA aneurysms after neck clipping.

    PubMed

    Sakaki, T; Takeshima, T; Tominaga, M; Hashimoto, H; Kawaguchi, S

    1994-01-01

    Between 1975 and 1992, 2211 patients underwent aneurysmal neck clipping at the Nara Medical University clinic and associated hospitals. The aneurysm in 931 of these patients was situated at the junction of the internal carotid artery (ICA) and posterior communicating artery (PCoA). Seven patients were readmitted 4 to 17 years after the first surgery because of regrowth and rupture of an ICA-PCoA aneurysmal sac that had arisen from the residual neck. On angiograms obtained following aneurysmal neck clipping, a large primitive type of PCoA was demonstrated in six patients and a small PCoA in one. A small residual aneurysm was confirmed in only two patients and angiographically complete neck clipping in five. Recurrent ICA-PCoA aneurysms were separated into two types based on the position of the old clip in relation to the new growth. Type 1 aneurysms regrow from the entire neck and balloon eccentrically. In this type, it is possible to apply the clip at the neck as in conventional clipping for a ruptured aneurysm. Type 2 includes aneurysms in which the proximal portion of a previous clip is situated at the corner of the ICA and aneurysmal neck and the distal portion on the enlarged dome of the aneurysm, because the sac is regrowing from a portion of the residual neck. In this type of aneurysm, a Sugita fenestrated clip can occlude the residual neck, overriding the old clip. Classifying these aneurysms into two groups is very useful from a surgical point of view because it is possible to apply a new clip without removing the old clip, which was found to be adherent to surrounding tissue.

  14. Automated revision of CLIPS rule-bases

    NASA Technical Reports Server (NTRS)

    Murphy, Patrick M.; Pazzani, Michael J.

    1994-01-01

    This paper describes CLIPS-R, a theory revision system for the revision of CLIPS rule-bases. CLIPS-R may be used for a variety of knowledge-base revision tasks, such as refining a prototype system, adapting an existing system to slightly different operating conditions, or improving an operational system that makes occasional errors. We present a description of how CLIPS-R revises rule-bases, and an evaluation of the system on three rule-bases.

  15. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    PubMed

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear regression model. Analysis of variance was used to determine whether the absolute log proportional error differed by the intended injection volume. Interindividual and intraindividual deviation from the intended injection volume was also characterized. As the intended injection volumes decreased, the absolute log proportional injection volume error increased (analysis of variance, P < .0018). The exploratory analysis revealed no significant difference in the standard deviations of the log proportional errors for injection volumes between physicians and pediatric PACU nurses; however, the difference in absolute bias was significantly higher for nurses with a 2-sided significance of P = .03. Clinically significant dose variation occurs when injecting volumes ≤0.5 mL. Administering small volumes of medications may result in unintended medication administration errors.

  16. CLIPS: A proposal for improved usability

    NASA Technical Reports Server (NTRS)

    Patton, Charles R.

    1990-01-01

    This paper proposes the enhancement of the CLIPS user interface to improve the over-all usability of the CLIPS development environment. It suggests some directions for the long term growth of the user interface, and discusses some specific strengths and weaknesses of the current CLIPS PC user interface. Every user of CLIPS shares a common experience: his/her first interaction with the system itself. As with any new language, between the process of installing CLIPS on the appropriate computer and the completion of a large application, an intensive learning process takes place. For those with extensive programming knowledge and LISP backgrounds, this experience may have been mostly interesting and pleasant. Being familiar with products that are similar to CLIPS in many ways, these users enjoy a relatively short training period with the product. Already familiar with many of the functions they wish to employ, experienced users are free to focus on the capabilities of CLIPS that make it uniquely useful within their working environment.

  17. Computational tests of quantum chemical models for excited and ionized states of molecules with phosphorus and sulfur atoms.

    PubMed

    Hahn, David K; RaghuVeer, Krishans; Ortiz, J V

    2014-05-15

    Time-dependent density functional theory (TD-DFT) and electron propagator theory (EPT) are used to calculate the electronic transition energies and ionization energies, respectively, of species containing phosphorus or sulfur. The accuracy of TD-DFT and EPT, in conjunction with various basis sets, is assessed with data from gas-phase spectroscopy. TD-DFT is tested using 11 prominent exchange-correlation functionals on a set of 37 vertical and 19 adiabatic transitions. For vertical transitions, TD-CAM-B3LYP calculations performed with the MG3S basis set are lowest in overall error, having a mean absolute deviation from experiment of 0.22 eV, or 0.23 eV over valence transitions and 0.21 eV over Rydberg transitions. Using a larger basis set, aug-pc3, improves accuracy over the valence transitions via hybrid functionals, but improved accuracy over the Rydberg transitions is only obtained via the BMK functional. For adiabatic transitions, all hybrid functionals paired with the MG3S basis set perform well, and B98 is best, with a mean absolute deviation from experiment of 0.09 eV. The testing of EPT used the Outer Valence Green's Function (OVGF) approximation and the Partial Third Order (P3) approximation on 37 vertical first ionization energies. It is found that OVGF outperforms P3 when basis sets of at least triple-ζ quality in the polarization functions are used. The largest basis set used in this study, aug-pc3, obtained the best mean absolute error from both methods -0.08 eV for OVGF and 0.18 eV for P3. The OVGF/6-31+G(2df,p) level of theory is particularly cost-effective, yielding a mean absolute error of 0.11 eV.

  18. A Simple Model Predicting Individual Weight Change in Humans

    PubMed Central

    Thomas, Diana M.; Martin, Corby K.; Heymsfield, Steven; Redman, Leanne M.; Schoeller, Dale A.; Levine, James A.

    2010-01-01

    Excessive weight in adults is a national concern with over 2/3 of the US population deemed overweight. Because being overweight has been correlated to numerous diseases such as heart disease and type 2 diabetes, there is a need to understand mechanisms and predict outcomes of weight change and weight maintenance. A simple mathematical model that accurately predicts individual weight change offers opportunities to understand how individuals lose and gain weight and can be used to foster patient adherence to diets in clinical settings. For this purpose, we developed a one dimensional differential equation model of weight change based on the energy balance equation is paired to an algebraic relationship between fat free mass and fat mass derived from a large nationally representative sample of recently released data collected by the Centers for Disease Control. We validate the model's ability to predict individual participants’ weight change by comparing model estimates of final weight data from two recent underfeeding studies and one overfeeding study. Mean absolute error and standard deviation between model predictions and observed measurements of final weights are less than 1.8 ± 1.3 kg for the underfeeding studies and 2.5 ± 1.6 kg for the overfeeding study. Comparison of the model predictions to other one dimensional models of weight change shows improvement in mean absolute error, standard deviation of mean absolute error, and group mean predictions. The maximum absolute individual error decreased by approximately 60% substantiating reliability in individual weight change predictions. The model provides a viable method for estimating individual weight change as a result of changes in intake and determining individual dietary adherence during weight change studies. PMID:24707319

  19. Seismic signals hard clipping overcoming

    NASA Astrophysics Data System (ADS)

    Olszowa, Paula; Sokolowski, Jakub

    2018-01-01

    In signal processing the clipping is understand as the phenomenon of limiting the signal beyond certain threshold. It is often related to overloading of a sensor. Two particular types of clipping are being recognized: soft and hard. Beyond the limiting value soft clipping reduces the signal real gain while the hard clipping stiffly sets the signal values at the limit. In both cases certain amount of signal information is lost. Obviously if one possess the model which describes the considered signal and the threshold value (which might be slightly more difficult to obtain in the soft clipping case), the attempt of restoring the signal can be made. Commonly it is assumed that the seismic signals take form of an impulse response of some specific system. This may lead to belief that the sine wave may be the most appropriate to fit in the clipping period. However, this should be tested. In this paper the possibility of overcoming the hard clipping in seismic signals originating from a geoseismic station belonging to an underground mine is considered. A set of raw signals will be hard-clipped manually and then couple different functions will be fitted and compared in terms of least squares. The results will be then analysed.

  20. CLIPS: The C language integrated production system

    NASA Technical Reports Server (NTRS)

    Riley, Gary

    1994-01-01

    Expert systems are computer programs which emulate human expertise in well defined problem domains. The potential payoff from expert systems is high: valuable expertise can be captured and preserved, repetitive and/or mundane tasks requiring human expertise can be automated, and uniformity can be applied in decision making processes. The C Language Integrated Production System (CLIPS) is an expert system building tool, developed at the Johnson Space Center, which provides a complete environment for the development and delivery of rule and/or object based expert systems. CLIPS was specifically designed to provide a low cost option for developing and deploying expert system applications across a wide range of hardware platforms. The commercial potential of CLIPS is vast. Currently, CLIPS is being used by over 5,000 individuals throughout the public and private sector. Because the CLIPS source code is readily available, numerous groups have used CLIPS as the basis for their own expert system tools. To date, three commercially available tools have been derived from CLIPS. In general, the development of CLIPS has helped to improve the ability to deliver expert system technology throughout the public and private sectors for a wide range of applications and diverse computing environments.

  1. 76 FR 26242 - Paper Clips From the People's Republic of China: Final Results of Expedited Sunset Review of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-06

    ... order are plastic and vinyl covered paper clips, butterfly clips, binder clips, or other paper fasteners... order is revoked. Parties can obtain a public copy of the I&D Memo from the Central Records Unit, room...

  2. Annual Removal of Aboveground Plant Biomass Alters Soil Microbial Responses to Warming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xue, Kai; Yuan, Mengting M.; Xie, Jianping

    Clipping (i.e., harvesting aboveground plant biomass) is common in agriculture and for bioenergy production. However, microbial responses to clipping in the context of climate warming are poorly understood. We investigated the interactive effects of grassland warming and clipping on soil properties and plant and microbial communities, in particular, on microbial functional genes. Clipping alone did not change the plant biomass production, but warming and clipping combined increased the C4 peak biomass by 47% and belowground net primary production by 110%. Clipping alone and in combination with warming decreased the soil carbon input from litter by 81% and 75%, respectively. Withmore » less carbon input, the abundances of genes involved in degrading relatively recalcitrant carbon increased by 38% to 137% in response to either clipping or the combined treatment, which could weaken long-term soil carbon stability and trigger positive feedback with respect to warming. Clipping alone also increased the abundance of genes for nitrogen fixation, mineralization, and denitrification by 32% to 39%. Such potentially stimulated nitrogen fixation could help compensate for the 20% decline in soil ammonium levels caused by clipping alone and could contribute to unchanged plant biomass levels. Moreover, clipping tended to interact antagonistically with warming, especially with respect to effects on nitrogen cycling genes, demonstrating that single-factor studies cannot predict multifactorial changes. These results revealed that clipping alone or in combination with warming altered soil and plant properties as well as the abundance and structure of soil microbial functional genes. Aboveground biomass removal for biofuel production needs to be reconsidered, as the long-term soil carbon stability may be weakened. IMPORTANCE Global change involves simultaneous alterations, including those caused by climate warming and land management practices (e.g., clipping). Data on the interactive effects of warming and clipping on ecosystems remain elusive, particularly in microbial ecology. This study found that clipping alters microbial responses to warming and demonstrated the effects of antagonistic interactions between clipping and warming on microbial functional genes. Clipping alone or combined with warming enriched genes degrading relatively recalcitrant carbon, likely reflecting the decreased quantity of soil carbon input from litter, which could weaken long-term soil C stability and trigger positive warming feedback. These results have important implications in assessing and predicting the consequences of global climate change and indicate that the removal of aboveground biomass for biofuel production may need to be reconsidered.« less

  3. Annual Removal of Aboveground Plant Biomass Alters Soil Microbial Responses to Warming

    DOE PAGES

    Xue, Kai; Yuan, Mengting M.; Xie, Jianping; ...

    2016-09-27

    Clipping (i.e., harvesting aboveground plant biomass) is common in agriculture and for bioenergy production. However, microbial responses to clipping in the context of climate warming are poorly understood. We investigated the interactive effects of grassland warming and clipping on soil properties and plant and microbial communities, in particular, on microbial functional genes. Clipping alone did not change the plant biomass production, but warming and clipping combined increased the C4 peak biomass by 47% and belowground net primary production by 110%. Clipping alone and in combination with warming decreased the soil carbon input from litter by 81% and 75%, respectively. Withmore » less carbon input, the abundances of genes involved in degrading relatively recalcitrant carbon increased by 38% to 137% in response to either clipping or the combined treatment, which could weaken long-term soil carbon stability and trigger positive feedback with respect to warming. Clipping alone also increased the abundance of genes for nitrogen fixation, mineralization, and denitrification by 32% to 39%. Such potentially stimulated nitrogen fixation could help compensate for the 20% decline in soil ammonium levels caused by clipping alone and could contribute to unchanged plant biomass levels. Moreover, clipping tended to interact antagonistically with warming, especially with respect to effects on nitrogen cycling genes, demonstrating that single-factor studies cannot predict multifactorial changes. These results revealed that clipping alone or in combination with warming altered soil and plant properties as well as the abundance and structure of soil microbial functional genes. Aboveground biomass removal for biofuel production needs to be reconsidered, as the long-term soil carbon stability may be weakened. IMPORTANCE Global change involves simultaneous alterations, including those caused by climate warming and land management practices (e.g., clipping). Data on the interactive effects of warming and clipping on ecosystems remain elusive, particularly in microbial ecology. This study found that clipping alters microbial responses to warming and demonstrated the effects of antagonistic interactions between clipping and warming on microbial functional genes. Clipping alone or combined with warming enriched genes degrading relatively recalcitrant carbon, likely reflecting the decreased quantity of soil carbon input from litter, which could weaken long-term soil C stability and trigger positive warming feedback. These results have important implications in assessing and predicting the consequences of global climate change and indicate that the removal of aboveground biomass for biofuel production may need to be reconsidered.« less

  4. Dual-Channel Endoscopic Indocyanine Green Fluorescence Angiography for Clipping of Cerebral Aneurysms.

    PubMed

    Cho, Won-Sang; Kim, Jeong Eun; Kang, Hyun-Seung; Ha, Eun Jin; Jung, Minwoong; Lee, Choonghee; Shin, Il Hyung; Kang, Uk

    2017-04-01

    Neuroendoscopy is useful for assessing status of perforators, parent arteries, and aneurysms beyond the straight line of microscopic view during aneurysm clipping. We aimed to evaluate the clinical usefulness of our endoscopic indocyanine green angiography (ICGA) system, which can simultaneously display visible light and indocyanine green fluorescent images. Surgical clipping of 16 unruptured aneurysms in 10 patients was performed via the keyhole approach. Using our endoscopic ICGA and commercial microscopic ICGA systems, we prospectively compared 10 targeted cerebral aneurysms at the posterior communicating (n = 4) and anterior choroidal (n = 6) arteries. Microscopic ICGA and endoscopic ICGA were feasible during surgery. Microscopic ICGA displayed 50% of branch orifices, 100% of branch trunks, and 20% of exact clip positions, whereas endoscopic ICGA showed 100% of these. Based on endoscopic ICGA findings such as incomplete clipping and compromise of parent arteries or branches, clips were repositioned in 2 cases, and additional clips were applied in 2 cases. Complete occlusion and residual neck states were achieved in 6 and 4 aneurysms after surgery. There were no neurologic deficits within 3 months after surgery except for frontalis palsy and anosmia in each patient. The endoscopic ICGA system with dual imaging of visible light and indocyanine green fluorescence was very useful for assessing geometry of aneurysms and surrounding vessels before clipping and for evaluating completeness of clip position after clipping. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Neural correlates of emotional regulation while viewing films.

    PubMed

    Shimamura, Arthur P; Marian, Diane E; Haskins, Andrew L

    2013-03-01

    Negative and arousal-inducing film clips were used to assess the neural correlates of emotional expression and suppression. Compared to viewing neutral clips, both negative (disgusting) and arousal (action) clips activated primarily posterior regions in the parietal and occipital cortex when participants were instructed to express their emotions. When instructed to suppress their emotions while viewing negative clips, a broad frontoparietal network was activated that included lateral, medial, and orbital regions in the prefrontal cortex as well as lateral and medial regions of the posterior parietal cortex. The suppression of arousal clips also activated prefrontal and parietal regions, though not to the same extent as the suppression of negative clips. The findings demonstrate the potency of using movies to engage emotional processes and highlight a broad frontoparietal network that is engaged during the suppression of negative film clips.

  6. IDENTIFICATION BADGE WITH DETACHABLE CLIP

    DOEpatents

    Burns, M.T.

    1962-09-18

    The clip has a long slot with a round enlarged end, flat on one side. The badge has a headed member that is circular except for a flat side. The badge is connected to, or disconnected from, the clip by insertion of the headed member through the enlarged end of the slot in the clip. The badge is unlikely to be accidentally disconnected from the clip while being worn on a worker's clothing, because the weight of the badge keeps the headed member away from the enlarged end of the slot in the clip, and the headed member can pass through the enlarged end of the slot only at one relative angular position between badge and clip, namely, that angle at which the flat side of the headed member is coincident with the flat side of the enlarged end of the slot. (AEC)

  7. Sex Differences in Emotional Evaluation of Film Clips: Interaction with Five High Arousal Emotional Categories

    PubMed Central

    Maffei, Antonio; Vencato, Valentina; Angrilli, Alessandro

    2015-01-01

    The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives. PMID:26717488

  8. 21 CFR 882.4215 - Clip rack.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip rack. 882.4215 Section 882.4215 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4215 Clip rack. (a) Identification. A clip rack is a...

  9. 21 CFR 882.4150 - Scalp clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Scalp clip. 882.4150 Section 882.4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4150 Scalp clip. (a) Identification. A scalp clip is a...

  10. 21 CFR 882.4150 - Scalp clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Scalp clip. 882.4150 Section 882.4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4150 Scalp clip. (a) Identification. A scalp clip is a...

  11. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  12. 21 CFR 882.4215 - Clip rack.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip rack. 882.4215 Section 882.4215 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4215 Clip rack. (a) Identification. A clip rack is a...

  13. 21 CFR 882.4175 - Aneurysm clip applier.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a) Identification. An aneurysm clip applier is a device used by the surgeon for holding and applying intracranial...

  14. 21 CFR 882.5200 - Aneurysm clip.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and... NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm clip is a device used to occlude an intracranial aneurysm (a balloonlike sac formed on a blood vessel...

  15. 21 CFR 882.4175 - Aneurysm clip applier.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a) Identification. An aneurysm clip applier is a device used by the surgeon for holding and applying intracranial...

  16. 21 CFR 882.5200 - Aneurysm clip.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and... NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm clip is a device used to occlude an intracranial aneurysm (a balloonlike sac formed on a blood vessel...

  17. 21 CFR 882.5200 - Aneurysm clip.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and... NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm clip is a device used to occlude an intracranial aneurysm (a balloonlike sac formed on a blood vessel...

  18. 21 CFR 882.4175 - Aneurysm clip applier.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a) Identification. An aneurysm clip applier is a device used by the surgeon for holding and applying intracranial...

  19. ESTIMATION OF RADIOACTIVE CALCIUM-45 BY LIQUID SCINTILLATION COUNTING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lutwak, L.

    1959-03-01

    A liquid sclntillation counting method is developed for determining radioactive calcium-45 in biological materials. The calcium-45 is extracted, concentrated, and dissolved in absolute ethyl alcohol to which is added 0.4% diphenyloxazol in toluene. Counting efficiency is about 65 percent with standard deviation of the J-57 engin 7.36 percent. (auth)

  20. A Robust Interpretation of Teaching Evaluation Ratings

    ERIC Educational Resources Information Center

    Bi, Henry H.

    2018-01-01

    There are no absolute standards regarding what teaching evaluation ratings are satisfactory. It is also problematic to compare teaching evaluation ratings with the average or with a cutoff number to determine whether they are adequate. In this paper, we use average and standard deviation charts (X[overbar]-S charts), which are based on the theory…

  1. Effects of thermo-order-mechanical coupling on band structures in liquid crystal nematic elastomer porous phononic crystals.

    PubMed

    Yang, Shuai; Liu, Ying

    2018-08-01

    Liquid crystal nematic elastomers are one kind of smart anisotropic and viscoelastic solids simultaneously combing the properties of rubber and liquid crystals, which is thermal sensitivity. In this paper, the wave dispersion in a liquid crystal nematic elastomer porous phononic crystal subjected to an external thermal stimulus is theoretically investigated. Firstly, an energy function is proposed to determine thermo-induced deformation in NE periodic structures. Based on this function, thermo-induced band variation in liquid crystal nematic elastomer porous phononic crystals is investigated in detail. The results show that when liquid crystal elastomer changes from nematic state to isotropic state due to the variation of the temperature, the absolute band gaps at different bands are opened or closed. There exists a threshold temperature above which the absolute band gaps are opened or closed. Larger porosity benefits the opening of the absolute band gaps. The deviation of director from the structural symmetry axis is advantageous for the absolute band gap opening in nematic state whist constrains the absolute band gap opening in isotropic state. The combination effect of temperature and director orientation provides an added degree of freedom in the intelligent tuning of the absolute band gaps in phononic crystals. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Cruise Summary of WHP P6, A10, I3 and I4 Revisits in 2003

    NASA Astrophysics Data System (ADS)

    Kawano, T.; Uchida, H.; Schneider, W.; Kumamoto, Y.; Nishina, A.; Aoyama, M.; Murata, A.; Sasaki, K.; Yoshikawa, Y.; Watanabe, S.; Fukasawa, M.

    2004-12-01

    Japan Agency for Marin-Earth Science and Technology (JAMSTEC) conducted a research cruise to round in the southern hemisphere by R/V Mirai. In this presentation, we introduce an outline of the cruise and data quality obtained during the cruise. The cruise started on Aug. 3, 2003 in Brisbane, Australia and sailed eastward until it reached Fremantle, Australia on Feb. 19, 2004. It contained six legs and legs 1, 2, 4 and 5 were revisits of WOCE Hydrographic Program (WHP) sections P6W, P6E, A10 and I3/I4, respectively. The sections consisted of about 500 hydrographic stations in total. On each station, CTD profiles and up to 36 water samples by 12L Niskin-X bottles were taken from the surface to within 10 m of the bottom. Water samples were analyzed at every station for salinity, dissolved oxygen (DO), and nutrients and at alternate stations for concentration of freons, dissolved inorganic carbon (CT), total alkalinity (AT), pH, and so on. Approximately 17,000 samples were obtained for salinity. The standard seawater was measured repeatedly to estimate the uncertainty caused by the setting and stability of the salinometer. The standard deviation of 699 repeated runs of standard seawater was 0.0002 in salinity. Replicate samples, which are a pair of samples drawn from the same Niskin bottle to different sample bottles, were taken to evaluate the overall uncertainty. The standard deviation of absolute differences of 2,769 replicates was also 0.0002 in salinity. For DO, about 13,400 samples were obtained. The analysis was made by a photometric titration technique. The reproducibility estimated from the absolute standard deviation of 1,625 replicates was about 0.09 umol/kg. CTD temperature was calibrated against a deep ocean standards thermometer (SBE35) which was attached to the CTD using a polynomial expression Tcal = T - (a +b*P + c*t), where Tcal is calibrated temperature, T is CTD temperature, P is CTD pressure and t is time. Calibration coefficients, a, b and c, were determined for each station by minimizing the sum of absolute deviation from SBE35 temperature below 2,000dbar. CTD salinity and DO were fitted to values obtained by sampled water analysis using similar polynomials. These corrections yielded deviations of about 0.0002 K in temperature, 0.0003 in salinity and 0.6 umol/kg in DO. Nutrients analyses were accomplished on 16,000 samples using the reference material of nutrients in seawater (RMNS). To establish the traceability and to get higher quality data, 500 bottles of RMNS from the same lot and 150 sets of RMNSs were used. The precisions of phosphate, nitrate and silicate measurements were 0.18 %, 0.17 % and 0.16 % in terms of median of those at 493 stations, respectively. The nutrients concentrations could be expressed with uncertainties explicitly because of the repeated runs of RMNSs. All the analyses for the CO{2}-system parameters in water columns were finished onboard. Analytical precisions of CT, AT and pH were estimated to be \\sim1.0 umol/kg, \\sim2.0 umol/kg, and \\sim7*10-4 pH unit, respectively. Approximately 6,300 samples were obtained for CFC-11 and CFC-12. The concentrations were determined with an electron capture detector - gas chromatograph (ECD-GC) attached the purge and trapping system. The reproducibility estimated from the absolute standard deviation of 365 replicates was less than 1% with respect to the surface concentrations.

  3. Estimation of the lower flammability limit of organic compounds as a function of temperature.

    PubMed

    Rowley, J R; Rowley, R L; Wilding, W V

    2011-02-15

    A new method of estimating the lower flammability limit (LFL) of general organic compounds is presented. The LFL is predicted at 298 K for gases and the lower temperature limit for solids and liquids from structural contributions and the ideal gas heat of formation of the fuel. The average absolute deviation from more than 500 experimental data points is 10.7%. In a previous study, the widely used modified Burgess-Wheeler law was shown to underestimate the effect of temperature on the lower flammability limit when determined in a large-diameter vessel. An improved version of the modified Burgess-Wheeler law is presented that represents the temperature dependence of LFL data determined in large-diameter vessels more accurately. When the LFL is estimated at increased temperatures using a combination of this model and the proposed structural-contribution method, an average absolute deviation of 3.3% is returned when compared with 65 data points for 17 organic compounds determined in an ASHRAE-style apparatus. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Extravasal occlusion of large vessels with titanic clips: efficiency, indications, and contraindications.

    PubMed

    Vasilenko, Yu V; Kim, A I; Kotov, S A

    2002-11-01

    The mechanism of extravasal occlusion of blood vessels with titanic clips "Atrauclip" and "Ligaclip extra" was studied in order to reveal indications and contraindications to their use. Occlusion with the clips of both types was ineffective in vessels with a diameter of >7.0 mm. Arteritis or the presence of an intravascular occlusion facility in the vessel were also the contraindications for clip occlusion. In overcases the procedure of occlusion with titanic clips was efficient and atraumatic.

  5. Influences of emotion on context memory while viewing film clips.

    PubMed

    Anderson, Lisa; Shimamura, Arthur P

    2005-01-01

    Participants listened to words while viewing film clips (audio off). Film clips were classified as neutral, positively valenced, negatively valenced, and arousing. Memory was assessed in three ways: recall of film content, recall of words, and context recognition. In the context recognition test, participants were presented a word and determined which film clip was showing when the word was originally presented. In two experiments, context memory performance was disrupted when words were presented during negatively valenced film clips, whereas it was enhanced when words were presented during arousing film clips. Free recall of words presented during the negatively valenced films was also disrupted. These findings suggest multiple influences of emotion on memory performance.

  6. Tricuspid Clip: Step-by-Step and Clinical Data.

    PubMed

    Tang, Gilbert H L

    2018-01-01

    Symptomatic severe tricuspid regurgitation (TR), if untreated, carries a dismal prognosis. These patients are at very high risk for surgical repair or replacement and transcatheter options to treat TR are emerging. More than 300 transcatheter tricuspid repairs with the MitraClip system have been performed worldwide with promising results. The TriClip system, with the MitraClip NT delivered via a dedicated tricuspid steerable guide catheter, is currently under investigation. This article describes the step-by-step technique on using the MitraClip system to perform transcatheter tricuspid repair using echocardiographic and fluoroscopic guidance. The latest data on worldwide experience with tricuspid clipping are also discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal scalp clip electrode and applicator. 884...

  8. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal scalp clip electrode and applicator. 884...

  9. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal scalp clip electrode and applicator. 884...

  10. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal scalp clip electrode and applicator. 884...

  11. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal scalp clip electrode and applicator. 884...

  12. The Effects of Multimodality through Storytelling Using Various Movie Clips

    ERIC Educational Resources Information Center

    Kim, SoHee

    2016-01-01

    This study examines the salient multimodal approaches for communicative competence and learners' reactions through storytelling tasks with three different modes: a silent movie clip, a movie clip with only sound effects, and a movie clip with sound effects and dialogue. In order to measure different multimodal effects and to define better delivery…

  13. Structural changes in the human vas deferens after tantalum clip occlusion and conventional vasectomy.

    PubMed

    Kothari, L K; Gupta, A S

    1978-02-01

    In 15 human subjects, the vasa deferentia were occluded by applying two tantalum clips on one side and by conventional vasectomy with silk ligatures on the other. After 2 weeks, the occluded segments were recovered for histopathologic examination of serial sections. Obstructing the seminal tract did not, as such, produce any significant change in the vas: the distal and proximal segments appeared to be essentially similar and normal. At the actual site of occlusion, however, tantalum clips produced marked flattening of the tube, complete loss of lining epithelium, distortion of the muscular lamellae, and areas of hemorrhage. The lumen was converted into a narrow slit. Under the ligatures, the damage was largely confined to denudation of the mucosal epithelium. The mucosa of the intersegment left unexcised between two clips showed hyalinization, invasion by macrophages, and degeneration of the epithelium. The changes under the clips suggest that, although clip occlusion may offer several advantages, sterility cannot be reversed merely by removing the clips. The mechanisms of these changes, different in the case of clips and ligatures, are discussed and some possible long-term consequences are considered.

  14. Application of Micromirror in Microsurgical Clipping to the Intracranial Aneurysms.

    PubMed

    Zhao, Chao; Ma, Zhiguo; Zhang, Yuhai; Mou, Shanling; Yang, Yunxue; Yang, Yonglin; Sun, Guoqing; Yao, Weicheng

    2018-05-01

    The aim of the study was to explore the values and disadvantages of micromirror in the intracranial aneurysm clipping surgery. Micromirror was used to assist microsurgical clipping to 36 intracranial aneurysms in 31 patients, of which 3 were carotid-ophthalmic artery aneurysms, 3 were anterior choroidal artery aneurysms, 11 were posterior communicating artery aneurysms, 7 were middle cerebral artery aneurysms, 10 were anterior communicating artery or anterior cerebral artery aneurysms, and the rest were a posterior cerebral artery aneurysm and a posterior inferior cerebellar artery aneurysm. The micromirror was used before and after clipping to observe the anatomic features of necks hidden behind and medial to aneurysms, to visualize surrounding neurovascular structures, and to verify the optimal clipping position. Intraoperative indocyanine green fluorescein angiography, postoperative computerized tomography angiography, and digital subtraction angiography confirmed the success of sufficient clipping. Intraoperative indocyanine green angiography, postoperative computerized tomography angiography , or digital subtraction angiography were performed and showed no case of wrong or insufficient clipping of aneurysm. Micromirror-assisted microsurgical clipping to the intracranial aneurysm is safe, sufficient, convenient, and practical.

  15. Gastric supply manipulation to modulate ghrelin production and enhance vascularization to the cardia: proof of the concept in a porcine model.

    PubMed

    Diana, Michele; Halvax, Peter; Pop, Raoul; Schlagowski, Isabel; Bour, Gaetan; Liu, Yu-Yin; Legner, Andras; Diemunsch, Pierre; Geny, Bernard; Dallemagne, Bernard; Beaujeux, Rémy; Demartines, Nicolas; Marescaux, Jacques

    2015-02-01

    Selective embolization of the left-gastric artery (LGA) reduces levels of ghrelin and achieves significant short-term weight loss. However, embolization of the LGA would prevent the performance of bariatric procedures because the high-risk leakage area (gastroesophageal junction [GEJ]) would be devascularized. To assess an alternative vascular approach to the modulation of ghrelin levels and generate a blood flow manipulation, consequently increasing the vascular supply to the GEJ. A total of 6 pigs underwent a laparoscopic clipping of the left gastroepiploic artery. Preoperative and postoperative CT angiographies were performed. Ghrelin levels were assessed perioperatively and then once per week for 3 weeks. Reactive oxygen species (ROS; expressed as ROS/mg of dry weight [DW]), mitochondria respiratory rate, and capillary lactates were assessed before and 1 hour after clipping (T0 and T1) and after 3 weeks of survival (T2), on seromuscular biopsies. A celiac trunk angiography was performed at 3 weeks. Mean (±standard deviation) ghrelin levels were significantly reduced 1 hour after clipping (1902 ± 307.8 pg/mL vs. 1084 ± 680.0; P = .04) and at 3 weeks (954.5 ± 473.2 pg/mL; P = .01). Mean ROS levels were statistically significantly decreased at the cardia at T2 when compared with T0 (0.018 ± 0.006 mg/DW vs. 0.02957 ± 0.0096 mg/DW; P = .01) and T1 (0.0376 ± 0.008 mg/DW; P = .007). Capillary lactates were significantly decreased after 3 weeks, and the mitochondria respiratory rate remained constant over time at the cardia and pylorus, showing significant regional differences. Manipulation of the gastric flow targeting the gastroepiploic arcade induces ghrelin reduction. An endovascular approach is currently under evaluation. © The Author(s) 2014.

  16. Evaluating the accuracy and large inaccuracy of two continuous glucose monitoring systems.

    PubMed

    Leelarathna, Lalantha; Nodale, Marianna; Allen, Janet M; Elleri, Daniela; Kumareswaran, Kavita; Haidar, Ahmad; Caldwell, Karen; Wilinska, Malgorzata E; Acerini, Carlo L; Evans, Mark L; Murphy, Helen R; Dunger, David B; Hovorka, Roman

    2013-02-01

    This study evaluated the accuracy and large inaccuracy of the Freestyle Navigator (FSN) (Abbott Diabetes Care, Alameda, CA) and Dexcom SEVEN PLUS (DSP) (Dexcom, Inc., San Diego, CA) continuous glucose monitoring (CGM) systems during closed-loop studies. Paired CGM and plasma glucose values (7,182 data pairs) were collected, every 15-60 min, from 32 adults (36.2±9.3 years) and 20 adolescents (15.3±1.5 years) with type 1 diabetes who participated in closed-loop studies. Levels 1, 2, and 3 of large sensor error with increasing severity were defined according to absolute relative deviation greater than or equal to ±40%, ±50%, and ±60% at a reference glucose level of ≥6 mmol/L or absolute deviation greater than or equal to ±2.4 mmol/L,±3.0 mmol/L, and ±3.6 mmol/L at a reference glucose level of <6 mmol/L. Median absolute relative deviation was 9.9% for FSN and 12.6% for DSP. Proportions of data points in Zones A and B of Clarke error grid analysis were similar (96.4% for FSN vs. 97.8% for DSP). Large sensor over-reading, which increases risk of insulin over-delivery and hypoglycemia, occurred two- to threefold more frequently with DSP than FSN (once every 2.5, 4.6, and 10.7 days of FSN use vs. 1.2, 2.0, and 3.7 days of DSP use for Level 1-3 errors, respectively). At levels 2 and 3, large sensor errors lasting 1 h or longer were absent with FSN but persisted with DSP. FSN and DSP differ substantially in the frequency and duration of large inaccuracy despite only modest differences in conventional measures of numerical and clinical accuracy. Further evaluations are required to confirm that FSN is more suitable for integration into closed-loop delivery systems.

  17. Light localization with low-contrast targets in a patient implanted with a suprachoroidal-transretinal stimulation retinal prosthesis.

    PubMed

    Endo, Takao; Fujikado, Takashi; Hirota, Masakazu; Kanda, Hiroyuki; Morimoto, Takeshi; Nishida, Kohji

    2018-04-20

    To evaluate the improvement in targeted reaching movements toward targets of various contrasts in a patient implanted with a suprachoroidal-transretinal stimulation (STS) retinal prosthesis. An STS retinal prosthesis was implanted in the right eye of a 42-year-old man with advanced Stargardt disease (visual acuity: right eye, light perception; left eye, hand motion). In localization tests during the 1-year follow-up period, the patient attempted to touch the center of a white square target (visual angle, 10°; contrast, 96, 85, or 74%) displayed at a random position on a monitor. The distance between the touched point and the center of the target (the absolute deviation) was averaged over 20 trials with the STS system on or off. With the left eye occluded, the absolute deviation was not consistently lower with the system on than off for high-contrast (96%) targets, but was consistently lower with the system on for low-contrast (74%) targets. With both eyes open, the absolute deviation was consistently lower with the system on than off for 85%-contrast targets. With the system on and 96%-contrast targets, we detected a shorter response time while covering the right eye, which was being implanted with the STS, compared to covering the left eye (2.41 ± 2.52 vs 8.45 ± 3.78 s, p < 0.01). Performance of a reaching movement improved in a patient with an STS retinal prosthesis implanted in an eye with residual natural vision. Patients with a retinal prosthesis may be able to improve their visual performance by using both artificial vision and their residual natural vision. Beginning date of the trial: Feb. 20, 2014 Date of registration: Jan. 4, 2014 Trial registration number: UMIN000012754 Registration site: UMIN Clinical Trials Registry (UMIN-CTR) http://www.umin.ac.jp/ctr/index.htm.

  18. Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment.

    PubMed

    Obermaier, Karin; Schmelzeisen-Redeker, Günther; Schoemaker, Michael; Klötzer, Hans-Martin; Kirchsteiger, Harald; Eikmeier, Heino; del Re, Luigi

    2013-07-01

    Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult. Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision. The combined use of MARD and PARD seems to allow for better characterization of sensor performance. The use of different quantities for calibration and evaluation, e.g., capillary blood using a blood glucose (BG) meter versus venous blood using a laboratory measurement, introduces an additional error source. Using BG values measured in more or less large intervals as the only reference leads to a significant loss of information in comparison with the continuous sensor signal and possibly to an erroneous estimation of sensor performance during swings. Both can be improved using data from two identical CGM sensors worn by the same patient in parallel. Evaluation of CGM performance studies should follow an identical study design, including sufficient swings in glycemia. At least a part of the study participants should wear two identical CGM sensors in parallel. All data available should be used for evaluation, both by MARD and PARD, a good PARD value being a precondition to trust a good MARD value. Results should be analyzed and presented separately for clinically different categories, e.g., hypoglycemia, exercise, or night and day. © 2013 Diabetes Technology Society.

  19. Urinary corticosterone responses to capture and toe-clipping in the cane toad (Rhinella marina) indicate that toe-clipping is a stressor for amphibians.

    PubMed

    Narayan, Edward J; Molinia, Frank C; Kindermann, Christina; Cockrem, John F; Hero, Jean-Marc

    2011-11-01

    Toe-clipping, the removal of one or more toes, is a common method used to individually mark free-living animals. Whilst this method is widely used in studies of amphibians, the appropriateness of the method, and its potential detrimental effects have been the subject of debate. Here, we provide for the first time, evidence that toe-clipping is a stressor in a wild amphibian. We measured urinary corticosterone responses of male cane toads (Rhinella marina) to capture and handling only, and to toe-clipping under field conditions. Urinary testosterone concentrations and white blood cell proportions were also measured. Urinary corticosterone metabolite concentrations increased 6h after capture and handling only and remained high for 24h; corticosterone returned to baseline levels after 48 h and remained low at 72 h post capture and handling. Corticosterone concentrations in toads subjected to toe-clipping increased at 6h to significantly higher concentrations than after capture and handling only, then decreased more slowly than after capture and handling, and were still elevated (approximately double basal level) 72 h after toe-clipping. Testosterone did not change significantly after capture and handling only, whereas after toe-clipping testosterone decreased at 6h and remained low at 72 h. There were weak short-term effects of toe-clipping compared with capture and handling only on white blood cell proportions. We have clearly shown that toe-clipping is a distinctly stronger stressor than capture and handling alone. This indicates that there is an ethical cost of toe-clipping, and this should be considered when planning studies of amphibians. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Image quality and artefact generation post-cerebral aneurysm clipping using a 64-row multislice computer tomography angiography (MSCTA) technology: A retrospective study and review of the literature.

    PubMed

    Zachenhofer, Iris; Cejna, Manfred; Schuster, Antonius; Donat, Markus; Roessler, Karl

    2010-06-01

    Computed tomography angiography (CTA) is a time and cost saving investigation for postoperative evaluation of clipped cerebral aneurysm patients. A retrospective study was conducted to analyse image quality and artefact generation due to implanted aneurysm clips using a new technology. MSCTA was performed pre- and postoperatively using a Philips Brilliance 64-detector-row CT scanner. Altogether, 32 clipping sites were analysed in 27 patients (11 female and 16 male, mean ages 52a, from 24 to 72 years). Clip number per aneurysm was 2.3 mean (from 1 to 4), 54 clips were made of titanium alloy and 5 of cobalt alloy. Altogether, image quality was rated 1.8 mean, using a scale from 1 (very good) to 5 (unserviceable) and clip artefacts were rated 2.4 mean, using a 5 point rating scale (1 no artefacts, 5 unserviceable due to artefacts). A significant loss of image quality and rise of artefacts was found when using cobalt alloy clips (1.4 versus 4.2 and 2.1 versus 4.0). In 72% of all investigations, an excellent image quality was found. Excluding the cobalt clip group, 85% of scans showed excellent image quality. Artefacts were absent or minimal (grade 1 or 2) in 69% of all investigations and in 81% in the pure titanium clip group. In 64-row MSCTA of good image quality with low artefacts, it was possible to detect small aneurysm remnants of 2mm size in individual patients. By using titanium alloy clips, in our study up to 85% of postoperative CTA images were of excellent quality with absent or minimal artefacts in 81% and seem adequate to detect small aneurysm remnants. Copyright 2010 Elsevier B.V. All rights reserved.

  1. Annual Removal of Aboveground Plant Biomass Alters Soil Microbial Responses to Warming

    PubMed Central

    Xue, Kai; Yuan, Mengting M.; Xie, Jianping; Li, Dejun; Qin, Yujia; Wu, Liyou; Deng, Ye; He, Zhili; Van Nostrand, Joy D.; Luo, Yiqi; Tiedje, James M.

    2016-01-01

    ABSTRACT Clipping (i.e., harvesting aboveground plant biomass) is common in agriculture and for bioenergy production. However, microbial responses to clipping in the context of climate warming are poorly understood. We investigated the interactive effects of grassland warming and clipping on soil properties and plant and microbial communities, in particular, on microbial functional genes. Clipping alone did not change the plant biomass production, but warming and clipping combined increased the C4 peak biomass by 47% and belowground net primary production by 110%. Clipping alone and in combination with warming decreased the soil carbon input from litter by 81% and 75%, respectively. With less carbon input, the abundances of genes involved in degrading relatively recalcitrant carbon increased by 38% to 137% in response to either clipping or the combined treatment, which could weaken long-term soil carbon stability and trigger positive feedback with respect to warming. Clipping alone also increased the abundance of genes for nitrogen fixation, mineralization, and denitrification by 32% to 39%. Such potentially stimulated nitrogen fixation could help compensate for the 20% decline in soil ammonium levels caused by clipping alone and could contribute to unchanged plant biomass levels. Moreover, clipping tended to interact antagonistically with warming, especially with respect to effects on nitrogen cycling genes, demonstrating that single-factor studies cannot predict multifactorial changes. These results revealed that clipping alone or in combination with warming altered soil and plant properties as well as the abundance and structure of soil microbial functional genes. Aboveground biomass removal for biofuel production needs to be reconsidered, as the long-term soil carbon stability may be weakened. PMID:27677789

  2. Practical Use of the Extended No Action Level (eNAL) Correction Protocol for Breast Cancer Patients With Implanted Surgical Clips

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Penninkhof, Joan, E-mail: j.penninkhof@erasmusmc.nl; Quint, Sandra; Baaijens, Margreet

    Purpose: To describe the practical use of the extended No Action Level (eNAL) setup correction protocol for breast cancer patients with surgical clips and evaluate its impact on the setup accuracy of both tumor bed and whole breast during simultaneously integrated boost treatments. Methods and Materials: For 80 patients, two orthogonal planar kilovoltage images and one megavoltage image (for the mediolateral beam) were acquired per fraction throughout the radiotherapy course. For setup correction, the eNAL protocol was applied, based on registration of surgical clips in the lumpectomy cavity. Differences with respect to application of a No Action Level (NAL) protocolmore » or no protocol were quantified for tumor bed and whole breast. The correlation between clip migration during the fractionated treatment and either the method of surgery or the time elapsed from last surgery was investigated. Results: The distance of the clips to their center of mass (COM), averaged over all clips and patients, was reduced by 0.9 {+-} 1.2 mm (mean {+-} 1 SD). Clip migration was similar between the group of patients starting treatment within 100 days after surgery (median, 53 days) and the group starting afterward (median, 163 days) (p = 0.20). Clip migration after conventional breast surgery (closing the breast superficially) or after lumpectomy with partial breast reconstructive techniques (sutured cavity). was not significantly different either (p = 0.22). Application of eNAL on clips resulted in residual systematic errors for the clips' COM of less than 1 mm in each direction, whereas the setup of the breast was within about 2 mm of accuracy. Conclusions: Surgical clips can be safely used for high-accuracy position verification and correction. Given compensation for time trends in the clips' COM throughout the treatment course, eNAL resulted in better setup accuracies for both tumor bed and whole breast than NAL.« less

  3. The effect of correct cross-chest clip use on injury outcomes in young children during motor vehicle crashes.

    PubMed

    Woodford, Evangeline; Brown, Julie; Bilston, Lynne E

    2018-05-19

    Traffic crashes have high mortality and morbidity for young children. Though many specialized child restraint systems improve injury outcomes, no large-scale studies have investigated the cross-chest clip's role during a crash, despite concerns in some jurisdictions about the potential for neck contact injuries from the clips. This study aimed to investigate the relationship between cross-chest clip use and injury outcomes in children between 0 and 4 years of age. Child passengers between 0 and 4 years of age were selected from the NASS-CDS data sets (2003-2014). Multiple regression analysis was used to model injury outcomes while controlling for age, crash severity, crash direction, and restraint type. The primary outcomes were overall Abbreviated Injury Score (AIS) 2+ injury, and the presence of any neck injury. Across all children aged 0-4 years, correct chest clip use was associated with decreased Abbreviated Injury Scale (AIS) 2+ injury (odds ratio [OR] = 0.44, 95% confidence interval [CI], 0.21-0.91) and was not associated with neck injury. However, outcomes varied by age. In children <12 months old, chest clip use was associated with decreased AIS 2+ injury (OR = 0.09, 95% CI, 0.02-0.44). Neck injury (n = 7, all AIS 1) for this age group only occurred with correct cross-chest clip use. For 1- to 4-year-old children, cross-chest clip use had no association with AIS 2+ injury, and correct use significantly decreased the odds of neck injury (OR = 0.49; 95% CI, 0.27-0.87) compared to an incorrectly used or absent cross-chest clip. No serious injuries were directly caused by the chest clips. Correct cross-chest clip use appeared to reduce injury in crashes, and there was no evidence of serious clip-induced injury in children in 5-point harness restraints.

  4. Prophylactic clipping for the prevention of bleeding following wide-field endoscopic mucosal resection of laterally spreading colorectal lesions: an economic modeling study.

    PubMed

    Bahin, Farzan F; Rasouli, Khalid N; Williams, Stephen J; Lee, Eric Y T; Bourke, Michael J

    2016-08-01

    Clinically significant bleeding (CSPEB) is the most common adverse event following endoscopic mucosal resection (EMR) of large sessile and laterally spreading colorectal lesions (LSLs), and is associated with morbidity and resource utilization. CSPEB occurs more frequently with proximal LSLs. Prophylactic clipping of the post-EMR defect may be beneficial in CSPEB prevention. The aim of this study was to determine the cost-effectiveness of a prophylactic clipping strategy. We hypothesized that prophylactic clipping in the proximal colon was cost-effective. An economic model was applied to outcomes from the Australian Colonic Endoscopic Mucosal Resection (ACE) Study. Clip distances of 3, 5, 8, and 10 mm were analyzed. The cost of treating CSPEB was determined from an independent costing agency. The funds needed to spend (FNS) was the cost incurred in order to prevent one episode of CSPEB. A break-even analysis was performed to determine cost equivalence of the costs of clipping and CSPEB. Outcomes of 1717 LSLs (mean size 35.8 mm; 52.6 % proximal colon) that underwent EMR were analyzed. The overall rate of CSPEB was 6.4 % (proximal 8.9 %; distal 3.7 %). Endoscopic management was required in 45 % of CSPEB episodes. With a clip distance of 3 mm, the expected cost of prophylactic clipping was € 1106 per lesion compared with € 157 per lesion for the expected cost of CSPEB without clipping. At 100 % clipping efficacy, the FNS was € 14 826 (proximal and distal lesions € 9309 and € 29 540, respectively). A clip price of € 10.35 was required for the cost of clipping to offset the cost of CSPEB. A prophylactic clipping strategy is not cost-effective and at present cannot be justified for all lesions or selectively for lesions in the proximal colon. ClinicalTrials.gov (NCT01368289). © Georg Thieme Verlag KG Stuttgart · New York.

  5. Prospective, randomized comparison of 3 different hemoclips for the treatment of acute upper GI hemorrhage in an established experimental setting.

    PubMed

    Kato, Masayuki; Jung, Yunho; Gromski, Mark A; Chuttani, Ram; Matthes, Kai

    2012-01-01

    Recently, endoscopic clip application devices have undergone redesign and improvements to optimize their clinical use and effectiveness. Initially designed for the treatment of bleeding nonvariceal lesions, these devices are also increasingly used for the closure of perforations, fistulas, and anastomotic leaks. Several clinical studies, both randomized and nonrandomized, have used endoscopic hemoclips for hemostasis. However, no comparative studies have yet been reported in the literature comparing the latest endoscopic clip devices for usability and effectiveness for hemostasis of acute upper GI hemorrhage. We aimed to compare the usability and efficacy of 3 different types of endoscopic clip application devices in an established experimental setting by using a porcine ex-vivo simulator of upper GI hemorrhage. Randomized, controlled, ex-vivo study. Academic medical center. Spurting vessels were created within ex-vivo porcine stomachs as published in prior studies. The vessels were attached to a pressure transducer to record the pressure of the circulating blood replacement. Before the initiation of bleeding, each vessel was randomized to 1 of 3 endoscopic clipping devices: 2 different commonly used hemoclips deployed through the working channel and 1 novel clip deployed via an over-the-scope applications device. Two investigators treated 45 bleeding sites (15 bleeding sites for each device at various randomized locations in the stomach: fundus, body, and antrum). Usability was measured via the endpoints of procedure time and quantity of clips required to achieve hemostasis. Efficacy was measured via the endpoint of pressure increase (Δp) from baseline to after treatment. All of the 45 hemostasis treatments were carried out successfully. The mean procedure times were significantly different among the hemoclips, with the clip deployed in an over-the-scope fashion requiring significantly less time to attain hemostasis compared with the other 2 clips. For number of clips needed to attain hemostasis, the clip deployed in an over-the-scope fashion was significantly superior to the others. There were also significant differences among the changes in pressure (Δp ± SD) among the different hemoclips tested. Ex-vivo study. In this prospective, randomized ex-vivo study, we observed significant differences in the usability (time to achieve hemostasis and number of clips required) and the efficacy (change in pressure achieved by the hemoclips) among the 3 clips. The clip applied in the over-the-scope fashion was superior to the other 2 tested clips with regard to time to achieve hemostasis and number of clips required. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  6. Short communication: Is hair cortisol a potential indicator for stress caused by chronic lameness in dairy cows?

    PubMed

    Fischer-Tenhagen, C; Ladwig-Wiegard, M; Heuwieser, W; Thöne-Reineke, C

    2018-06-01

    The objective of this study was to evaluate hair cortisol concentration as an indicator for stress caused by chronic lameness in dairy cows. Sixty-eight cows were scored for lameness for 4 consecutive weeks. The hair of the tail switch was clipped at the beginning of the study and regrown hair was clipped after 4 wk. Hair samples were analyzed for cortisol concentration. Animals with 2 consecutive locomotion scores ≥3 or with an overall mean score >1.5 were classified as lame. After pair matching lame and nonlame cows, considering days in milk, lactation number, and milk yield, and excluding cows with less than 20 mg hair sample for analysis, 21 lame and 21 nonlame cows were included in the analysis. The mean hair cortisol concentration in this study was 2.32 ± 0.35 pg/mg (mean ± standard deviation). Cortisol concentration from hair regrown in the study period was 2.38 ± 0.95 and 2.26 ± 1.35 pg/mg for lame and nonlame cows (n = 21), respectively; we found no difference in mean cortisol level of primiparous and multiparous cows. Based on these data, hair cortisol concentration was not a useful indicator to differentiate cows with chronic lameness and healthy cows. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. 76 FR 31360 - Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-31

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-663 Third Review] Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping Duty Order on Paper Clips From China... paper clips from China would be likely to lead to continuation or recurrence of material injury within a...

  8. 76 FR 44575 - Paper Clips From the People's Republic of China: Continuation of the Antidumping Duty Order

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-26

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-826] Paper Clips From the People... the antidumping duty order on paper clips from the People's Republic of China (``PRC'') would likely... of the antidumping duty order on paper clips from the PRC pursuant to section 751(c) of the Tariff...

  9. 78 FR 78319 - Media Bureau Seeks Comment on Application of the IP Closed Captioning Rules to Video Clips

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... Seeks Comment on Application of the IP Closed Captioning Rules to Video Clips AGENCY: Federal... captioning of video clips delivered by Internet protocol (``IP''), including the extent to which industry has voluntarily captioned IP- delivered video clips. The Commission directed the Media Bureau to issue this...

  10. The truly remarkable universality of half a standard deviation: confirmation through another look.

    PubMed

    Norman, Geoffrey R; Sloan, Jeff A; Wyrwich, Kathleen W

    2004-10-01

    In this issue of Expert Review of Pharmacoeconomics and Outcomes Research, Farivar, Liu, and Hays present their findings in 'Another look at the half standard deviation estimate of the minimally important difference in health-related quality of life scores (hereafter referred to as 'Another look') . These researchers have re-examined the May 2003 Medical Care article 'Interpretation of changes in health-related quality of life: the remarkable universality of half a standard deviation' (hereafter referred to as 'Remarkable') in the hope of supporting their hypothesis that the minimally important difference in health-related quality of life measures is undoubtedly closer to 0.3 standard deviations than 0.5. Nonetheless, despite their extensive wranglings with the exclusion of many articles that we included in our review; the inclusion of articles that we did not include in our review; and the recalculation of effect sizes using the absolute value of the mean differences, in our opinion, the results of the 'Another look' article confirm the same findings in the 'Remarkable' paper.

  11. Catheter Entrapment During Posterior Mitral Leaflet Pushing Maneuver for MitraClip Implantation.

    PubMed

    Castrodeza, Javier; Amat-Santos, Ignacio J; Tobar, Javier; Varela-Falcón, Luis H

    2016-06-01

    MitraClip (Abbott Vascular) therapy has been reported to be an effective procedure for mitral regurgitation, especially in high-risk patients. Recently, the novel pushing maneuver technique has been described for approaching restricted and short posterior leaflets with a pigtail catheter in order to facilitate grasping of the clip. However, complications or unexpected situations may occur. We report the case of an 84-year-old patient who underwent MitraClip implantation wherein the pushing maneuver was complicated by the clip accidentally gripping the pigtail catheter along with the two leaflets.

  12. Integrating an object system into CLIPS: Language design and implementation issues

    NASA Technical Reports Server (NTRS)

    Auburn, Mark

    1990-01-01

    This paper describes the reasons why an object system with integrated pattern-matching and object-oriented programming facilities is desirable for CLIPS and how it is possible to integrate such a system into CLIPS while maintaining the run-time performance and the low memory usage for which CLIPS is known. The requirements for an object system in CLIPS that includes object-oriented programming and integrated pattern-matching are discussed and various techniques for optimizing the object system and its integration with the pattern-matcher are presented.

  13. CLIPS: A tool for the development and delivery of expert systems

    NASA Technical Reports Server (NTRS)

    Riley, Gary

    1991-01-01

    The C Language Integrated Production System (CLIPS) is a forward chaining rule-based language developed by the Software Technology Branch at the Johnson Space Center. CLIPS provides a complete environment for the construction of rule-based expert systems. CLIPS was designed specifically to provide high probability, low cost, and easy integration with external systems. Other key features of CLIPS include a powerful rule syntax, an interactive development environment, high performance, extensibility, a verification/validation tool, extensive documentation, and source code availability. The current release of CLIPS, version 4.3, is being used by over 2,500 users throughout the public and private community including: all NASA sites and branches of the military, numerous Federal bureaus, government contractors, 140 universities, and many companies.

  14. A standardized model for predicting flap failure using indocyanine green dye

    NASA Astrophysics Data System (ADS)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  15. Absolute Parameters for the F-type Eclipsing Binary BW Aquarii

    NASA Astrophysics Data System (ADS)

    Maxted, P. F. L.

    2018-05-01

    BW Aqr is a bright eclipsing binary star containing a pair of F7V stars. The absolute parameters of this binary (masses, radii, etc.) are known to good precision so they are often used to test stellar models, particularly in studies of convective overshooting. ... Maxted & Hutcheon (2018) analysed the Kepler K2 data for BW Aqr and noted that it shows variability between the eclipses that may be caused by tidally induced pulsations. ... Table 1 shows the absolute parameters for BW Aqr derived from an improved analysis of the Kepler K2 light curve plus the RV measurements from both Imbert (1979) and Lester & Gies (2018). ... The values in Table 1 with their robust error estimates from the standard deviation of the mean are consistent with the values and errors from Maxted & Hutcheon (2018) based on the PPD calculated using emcee for a fit to the entire K2 light curve.

  16. Measurement of the cosmic microwave background spectrum by the COBE FIRAS instrument

    NASA Technical Reports Server (NTRS)

    Mather, J. C.; Cheng, E. S.; Cottingham, D. A.; Eplee, R. E., Jr.; Fixsen, D. J.; Hewagama, T.; Isaacman, R. B.; Jensen, K. A.; Meyer, S. S.; Noerdlinger, P. D.

    1994-01-01

    The cosmic microwave background radiation (CMBR) has a blackbody spectrum within 3.4 x 10(exp -8) ergs/sq cm/s/sr cm over the frequency range from 2 to 20/cm (5-0.5 mm). These measurements, derived from the Far-Infrared Absolute Spectrophotomer (FIRAS) instrument on the Cosmic Background Explorer (COBE) satellite, imply stringent limits on energy release in the early universe after t approximately 1 year and redshift z approximately 3 x 10(exp 6). The deviations are less than 0.30% of the peak brightness, with an rms value of 0.01%, and the dimensionless cosmological distortion parameters are limited to the absolute value of y is less than 2.5 x 10(exp -5) and the absolute value of mu is less than 3.3 x 10(exp -4) (95% confidence level). The temperature of the CMBR is 2.726 +/- 0.010 K (95% confidence level systematic).

  17. Flat panel angiography images in the post-operative follow-up of surgically clipped intracranial aneurysms.

    PubMed

    Budai, Caterina; Cirillo, Luigi; Patruno, Francesco; Dall'olio, Massimo; Princiotta, Ciro; Leonardi, Marco

    2014-04-01

    Cerebral aneurysms must be monitored for varying periods after surgical and/or endovascular treatment and the duration of follow-up will depend on the type of therapy and the immediate post-operative outcome. Surgical clipping for intracranial aneurysms is a valid treatment but the metal clips generate artefacts so that follow-up monitoring still relies on catheter angiography. This study reports our preliminary experience with volumetric angiography using a Philips Allura Xper FD biplane system in the post-operative monitoring of aneurysm residues or major vascular changes following the surgical clipping of intracranial aneurysms. Volumetric angiography yields not only volume-rendered (VR) images, but a volume CT can also be reconstructed at high spatial and contrast resolution from a single acquisition, significantly enhancing the technique's diagnostic power. Between August 2012 and April 2013, we studied 19 patients with a total of 26 aneurysms treated by surgical clipping alone or in combination with endovascular treatment. All patients underwent standard post-operative angiographic follow-up including a rotational volumetric acquisition. Follow-up monitoring disclosed eight aneurysm residues whose assessment was optimal after surgical clipping both in patients with one metal clip and in those with two or more clips. In addition, small residues (1.3 mm) could be monitored together with any change in the calibre or course of vessels located adjacent to the clips. In conclusion, flat panel volume CT is much more reliable than the old 3D acquisitions that yielded only VR images. This is particularly true in patients with small aneurysm residues or lesions with multiple metal clips.

  18. Virtual Cerebral Aneurysm Clipping with Real-Time Haptic Force Feedback in Neurosurgical Education.

    PubMed

    Gmeiner, Matthias; Dirnberger, Johannes; Fenz, Wolfgang; Gollwitzer, Maria; Wurm, Gabriele; Trenkler, Johannes; Gruber, Andreas

    2018-04-01

    Realistic, safe, and efficient modalities for simulation-based training are highly warranted to enhance the quality of surgical education, and they should be incorporated in resident training. The aim of this study was to develop a patient-specific virtual cerebral aneurysm-clipping simulator with haptic force feedback and real-time deformation of the aneurysm and vessels. A prototype simulator was developed from 2012 to 2016. Evaluation of virtual clipping by blood flow simulation was integrated in this software, and the prototype was evaluated by 18 neurosurgeons. In 4 patients with different medial cerebral artery aneurysms, virtual clipping was performed after real-life surgery, and surgical results were compared regarding clip application, surgical trajectory, and blood flow. After head positioning and craniotomy, bimanual virtual aneurysm clipping with an original forceps was performed. Blood flow simulation demonstrated residual aneurysm filling or branch stenosis. The simulator improved anatomic understanding for 89% of neurosurgeons. Simulation of head positioning and craniotomy was considered realistic by 89% and 94% of users, respectively. Most participants agreed that this simulator should be integrated into neurosurgical education (94%). Our illustrative cases demonstrated that virtual aneurysm surgery was possible using the same trajectory as in real-life cases. Both virtual clipping and blood flow simulation were realistic in broad-based but not calcified aneurysms. Virtual clipping of a calcified aneurysm could be performed using the same surgical trajectory, but not the same clip type. We have successfully developed a virtual aneurysm-clipping simulator. Next, we will prospectively evaluate this device for surgical procedure planning and education. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Energizing Staff Development Using Film Clips: Memorable Movie Moments that Promote Reflection, Conversation, and Action

    ERIC Educational Resources Information Center

    Olsen, Walter R.; Sommers, William A.

    2005-01-01

    Video and DVD clips give participants an opportunity to explore values and ideas, learn about one another, and, in the process, build a stronger learning community. "Energizing Staff Development Using Film Clips" is a collection of film and television clips that staff developers can use to encourage discussion and reflection on pertinent, common…

  20. [Reliable fixation of cochlear implant electrode mountings in children and adults--initial experiences with a new titanium clip].

    PubMed

    Müller, J; Schön, F; Helms, J

    1998-04-01

    There is a reported 1% incidence of delayed migration of extrusions of the electrode arrays out of the cochlea. A titanium clip to fix the electrode array of the MED EL Combi 40 Cochlear Implant System is described. The clip is designed and shaped in a double U configuration. The clip material allows easy adaption to the individual anatomical situation. The clip is fixed to a bony bridge at the incus bar and fixes the electrode in a plane parallel to the chorda facial angle. It is closed around the electrode similarly to a stapes piston around the incus. Additional tests which examined the possible risk of damaging the electrode carrier and clinical findings are described. The clip was used in 23 cases with a follow-up period up to 1 year. No signs for dislocation of the electrode were found. In one revision case the clip was covered with a thin mucosal layer. The electrode array showed no signs of damage. Intraoperative findings confirmed the experimental tests on the electrode fixation. The titanium clip facilitates safe and quick fixation of the electrode array and prevents dislocation. its flexibility and shape minimizes the risk of damage.

  1. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips

    PubMed Central

    Schulz-Wendtland, R.; Dankerl, P.; Dilbat, G.; Bani, M.; Fasching, P. A.; Heusinger, K.; Lux, M. P.; Loehberg, C. R.; Jud, S. M.; Rauh, C.; Bayer, C. M.; Beckmann, M. W.; Wachter, D. L.; Uder, M.; Meier-Meitinger, M.; Brehm, B.

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p < 0.05). Conclusion: The use of digital breast tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography. PMID:25684789

  2. A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability.

    PubMed

    Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Ropers, H Hilger; Galjart, Niels; Najmabadi, Hossein

    2015-03-01

    In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score = 3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which specifically associates with the ends of growing MTs. These proteins regulate MT dynamic behavior and are important for MT-mediated transport over the length of axons and dendrites. As such, CLIP1 may have a role in neuronal development. We studied lymphoblastoid and skin fibroblast cell lines established from healthy and affected patients. RT-PCR and western blot analyses showed the absence of CLIP1 transcript and protein in lymphoblastoid cells derived from affected patients. Furthermore, immunofluorescence analyses showed MT plus-end staining only in fibroblasts containing the wild-type (and not the mutant) CLIP1 protein. Collectively, our data suggest that defects in CLIP1 may lead to ARID.

  3. A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability

    PubMed Central

    Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Ropers, H Hilger; Galjart, Niels; Najmabadi, Hossein

    2015-01-01

    In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score=3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which specifically associates with the ends of growing MTs. These proteins regulate MT dynamic behavior and are important for MT-mediated transport over the length of axons and dendrites. As such, CLIP1 may have a role in neuronal development. We studied lymphoblastoid and skin fibroblast cell lines established from healthy and affected patients. RT-PCR and western blot analyses showed the absence of CLIP1 transcript and protein in lymphoblastoid cells derived from affected patients. Furthermore, immunofluorescence analyses showed MT plus-end staining only in fibroblasts containing the wild-type (and not the mutant) CLIP1 protein. Collectively, our data suggest that defects in CLIP1 may lead to ARID. PMID:24569606

  4. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    PubMed

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  5. The Emotional Movie Database (EMDB): a self-report and psychophysiological study.

    PubMed

    Carvalho, Sandra; Leite, Jorge; Galdo-Álvarez, Santiago; Gonçalves, Oscar F

    2012-12-01

    Film clips are an important tool for evoking emotional responses in the laboratory. When compared with other emotionally potent visual stimuli (e.g., pictures), film clips seem to be more effective in eliciting emotions for longer periods of time at both the subjective and physiological levels. The main objective of the present study was to develop a new database of affective film clips without auditory content, based on a dimensional approach to emotional stimuli (valence, arousal and dominance). The study had three different phases: (1) the pre-selection and editing of 52 film clips (2) the self-report rating of these film clips by a sample of 113 participants and (3) psychophysiological assessment [skin conductance level (SCL) and the heart rate (HR)] on 32 volunteers. Film clips from different categories were selected to elicit emotional states from different quadrants of affective space. The results also showed that sustained exposure to the affective film clips resulted in a pattern of a SCL increase and HR deceleration in high arousal conditions (i.e., horror and erotic conditions). The resulting emotional movie database can reliably be used in research requiring the presentation of non-auditory film clips with different ratings of valence, arousal and dominance.

  6. The effect of positive and negative movie alcohol portrayals on transportation and attitude toward the movie.

    PubMed

    Koordeman, Renske; Anschutz, Doeschka J; Engels, Rutger C M E

    2014-07-01

    This study examined the effects of alcohol portrayals on transportation and attitude toward a movie. In addition, we examined whether positive and negative movie alcohol portrayals affect transportation into and attitude toward the movie. A within-subject design was used in which participants were exposed to 8 different movie clips containing alcohol (positive or negative context) or no alcohol portrayals in a controlled laboratory setting. A total of 159 college students (84 males and 75 females) ages 18 to 30 participated in the experiment. Transportation and attitude toward the movie were measured after each movie clip. Participants were more transported into and had a more positive attitude toward movie clips with alcohol portrayals compared to the same movie clips with no alcohol portrayal. In addition, participants were more transported into movie clips with negative alcohol (NA) portrayals compared to clips with positive alcohol (PA) portrayals. For attitude toward the movie, opposite results were found. Participants had a more positive attitudes toward clips with PA portrayals compared to clips with NA portrayals. The way alcohol is portrayed in movies may contribute to how people evaluate and get transported in movies. Copyright © 2014 by the Research Society on Alcoholism.

  7. A FORMULA FOR HUMAN PAROTID FLUID COLLECTED WITHOUT EXOGENEOUS STIMULATION.

    DTIC Science & Technology

    Parotid fluid was collected from 4,589 systemically healthy males between 17 and 22 years of age. Collection devices were placed with an absolute...secretion of the parotid gland. For all 4,589 subjects from the 8 experiments the mean rate of flow was 0.040 ml./minute with an average standard deviation of

  8. The Local Minima Problem in Hierarchical Classes Analysis: An Evaluation of a Simulated Annealing Algorithm and Various Multistart Procedures

    ERIC Educational Resources Information Center

    Ceulemans, Eva; Van Mechelen, Iven; Leenen, Iwin

    2007-01-01

    Hierarchical classes models are quasi-order retaining Boolean decomposition models for N-way N-mode binary data. To fit these models to data, rationally started alternating least squares (or, equivalently, alternating least absolute deviations) algorithms have been proposed. Extensive simulation studies showed that these algorithms succeed quite…

  9. 40 CFR 1065.1005 - Symbols, abbreviations, acronyms, and units of measure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of diameters meter per meter m/m 1 b atomic oxygen-to-carbon ratio mole per mole mol/mol 1 C # number... error between a quantity and its reference e brake-specific emission or fuel consumption gram per... standard deviation S Sutherland constant kelvin K K SEE standard estimate of error T absolute temperature...

  10. PCLIPS: Parallel CLIPS

    NASA Technical Reports Server (NTRS)

    Hall, Lawrence O.; Bennett, Bonnie H.; Tello, Ivan

    1994-01-01

    A parallel version of CLIPS 5.1 has been developed to run on Intel Hypercubes. The user interface is the same as that for CLIPS with some added commands to allow for parallel calls. A complete version of CLIPS runs on each node of the hypercube. The system has been instrumented to display the time spent in the match, recognize, and act cycles on each node. Only rule-level parallelism is supported. Parallel commands enable the assertion and retraction of facts to/from remote nodes working memory. Parallel CLIPS was used to implement a knowledge-based command, control, communications, and intelligence (C(sup 3)I) system to demonstrate the fusion of high-level, disparate sources. We discuss the nature of the information fusion problem, our approach, and implementation. Parallel CLIPS has also be used to run several benchmark parallel knowledge bases such as one to set up a cafeteria. Results show from running Parallel CLIPS with parallel knowledge base partitions indicate that significant speed increases, including superlinear in some cases, are possible.

  11. Short term exposure to attractive and muscular singers in music video clips negatively affects men's body image and mood.

    PubMed

    Mulgrew, K E; Volcevski-Kostas, D

    2012-09-01

    Viewing idealized images has been shown to reduce men's body satisfaction; however no research has examined the impact of music video clips. This was the first study to examine the effects of exposure to muscular images in music clips on men's body image, mood and cognitions. Ninety men viewed 5 min of clips containing scenery, muscular or average-looking singers, and completed pre- and posttest measures of mood and body image. Appearance schema activation was also measured. Men exposed to the muscular clips showed poorer posttest levels of anger, body and muscle tone satisfaction compared to men exposed to the scenery or average clips. No evidence of schema activation was found, although potential problems with the measure are noted. These preliminary findings suggest that even short term exposure to music clips can produce negative effects on men's body image and mood. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Virus-Clip: a fast and memory-efficient viral integration site detection tool at single-base resolution with annotation capability.

    PubMed

    Ho, Daniel W H; Sze, Karen M F; Ng, Irene O L

    2015-08-28

    Viral integration into the human genome upon infection is an important risk factor for various human malignancies. We developed viral integration site detection tool called Virus-Clip, which makes use of information extracted from soft-clipped sequencing reads to identify exact positions of human and virus breakpoints of integration events. With initial read alignment to virus reference genome and streamlined procedures, Virus-Clip delivers a simple, fast and memory-efficient solution to viral integration site detection. Moreover, it can also automatically annotate the integration events with the corresponding affected human genes. Virus-Clip has been verified using whole-transcriptome sequencing data and its detection was validated to have satisfactory sensitivity and specificity. Marked advancement in performance was detected, compared to existing tools. It is applicable to versatile types of data including whole-genome sequencing, whole-transcriptome sequencing, and targeted sequencing. Virus-Clip is available at http://web.hku.hk/~dwhho/Virus-Clip.zip.

  13. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION)

    NASA Technical Reports Server (NTRS)

    Riley, G.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh version each contain a windowing variant of CLIPS as well as the standard line oriented version. The mouse/window interface version for the PC works with a Microsoft compatible mouse or without a mouse. This window version uses the proprietary CURSES library for the PC, but a working executable of the window version is provided. The window oriented version for the Macintosh includes a version which uses a full Macintosh-style interface, including an integrated editor. This version allows the user to observe the changing fact base and rule activations in separate windows while a CLIPS program is executing. The IBM PC version is available bundled with CLIPSITS, The CLIPS Intelligent Tutoring System for a special combined price (COS-10025). The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. The program was developed for the IBM PC series with a hard disk. CLIPSITS is also available separately as MSC-21679. The CLIPS program is written in C for interactive execution and has been implemented on an IBM PC computer operating under DOS, a Macintosh and DEC VAX series computers operating under VMS or ULTRIX. The line oriented version should run on any computer system which supports a full (Kernighan and Ritchie) C compiler or the ANSI standard C language. CLIPS was developed in 1986 and Version 4.2 was released in July of 1988. Version 4.3 was released in June of 1989.

  14. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (MACINTOSH VERSION)

    NASA Technical Reports Server (NTRS)

    Culbert, C.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh version each contain a windowing variant of CLIPS as well as the standard line oriented version. The mouse/window interface version for the PC works with a Microsoft compatible mouse or without a mouse. This window version uses the proprietary CURSES library for the PC, but a working executable of the window version is provided. The window oriented version for the Macintosh includes a version which uses a full Macintosh-style interface, including an integrated editor. This version allows the user to observe the changing fact base and rule activations in separate windows while a CLIPS program is executing. The IBM PC version is available bundled with CLIPSITS, The CLIPS Intelligent Tutoring System for a special combined price (COS-10025). The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. The program was developed for the IBM PC series with a hard disk. CLIPSITS is also available separately as MSC-21679. The CLIPS program is written in C for interactive execution and has been implemented on an IBM PC computer operating under DOS, a Macintosh and DEC VAX series computers operating under VMS or ULTRIX. The line oriented version should run on any computer system which supports a full (Kernighan and Ritchie) C compiler or the ANSI standard C language. CLIPS was developed in 1986 and Version 4.2 was released in July of 1988. Version 4.3 was released in June of 1989.

  15. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION WITH CLIPSITS)

    NASA Technical Reports Server (NTRS)

    Riley, , .

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh version each contain a windowing variant of CLIPS as well as the standard line oriented version. The mouse/window interface version for the PC works with a Microsoft compatible mouse or without a mouse. This window version uses the proprietary CURSES library for the PC, but a working executable of the window version is provided. The window oriented version for the Macintosh includes a version which uses a full Macintosh-style interface, including an integrated editor. This version allows the user to observe the changing fact base and rule activations in separate windows while a CLIPS program is executing. The IBM PC version is available bundled with CLIPSITS, The CLIPS Intelligent Tutoring System for a special combined price (COS-10025). The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. The program was developed for the IBM PC series with a hard disk. CLIPSITS is also available separately as MSC-21679. The CLIPS program is written in C for interactive execution and has been implemented on an IBM PC computer operating under DOS, a Macintosh and DEC VAX series computers operating under VMS or ULTRIX. The line oriented version should run on any computer system which supports a full (Kernighan and Ritchie) C compiler or the ANSI standard C language. CLIPS was developed in 1986 and Version 4.2 was released in July of 1988. Version 4.3 was released in June of 1989.

  16. Apparatus for the compact cooling of modules

    DOEpatents

    Iyengar, Madhusudan K.; Parida, Pritish R.

    2015-07-07

    An apparatus for the compact cooling of modules. The apparatus includes a clip, a first cover plate coupled to a first side of the clip, a second cover plate coupled to a second side of the clip opposite to the first side of the clip, a first frame thermally coupled to the first cover plate, and a second frame thermally coupled to the second cover plate. Each of the first frame and the second frame may include a plurality of channels for passing coolant through the first frame and the second frame, respectively. Additionally, the apparatus may further include a filler for directing coolant through the plurality of channels, and for blocking coolant from flowing along the first side of the clip and the second side of the clip.

  17. Importance of nasal clipping in screening investigations of flow volume curve.

    PubMed

    Yanev, I

    1992-01-01

    Comparative analysis of some basic lung indices obtained from a screening investigation of the flow volume curve by using two techniques, with a nose clip and without a nose clip, was made on a cohort of 86 workers in a factory shop for the production of bearings. We found no statistically significant differences between the indices obtained by the two techniques. Our study showed that the FVC and FEV1 obtained in workers without using nose clips were equal to or better than those obtained using nose clips in 60% of the workers. The reproducibility of the two methods was similar. The analysis of the data has shown that the flow volume curve investigation gives better results when performed without a nose clip, especially in industrial conditions.

  18. CLIPS/Ada: An Ada-based tool for building expert systems

    NASA Technical Reports Server (NTRS)

    White, W. A.

    1990-01-01

    Clips/Ada is a production system language and a development environment. It is functionally equivalent to the CLIPS tool. CLIPS/Ada was developed in order to provide a means of incorporating expert system technology into projects where the use of the Ada language had been mandated. A secondary purpose was to glean information about the Ada language and its compilers. Specifically, whether or not the language and compilers were mature enough to support AI applications. The CLIPS/Ada tool is coded entirely in Ada and is designed to be used by Ada systems that require expert reasoning.

  19. A distributed Clips implementation: dClips

    NASA Technical Reports Server (NTRS)

    Li, Y. Philip

    1993-01-01

    A distributed version of the Clips language, dClips, was implemented on top of two existing generic distributed messaging systems to show that: (1) it is easy to create a coarse-grained parallel programming environment out of an existing language if a high level messaging system is used; and (2) the computing model of a parallel programming environment can be changed easily if we change the underlying messaging system. dClips processes were first connected with a simple master-slave model. A client-server model with intercommunicating agents was later implemented. The concept of service broker is being investigated.

  20. Water quality management using statistical analysis and time-series prediction model

    NASA Astrophysics Data System (ADS)

    Parmar, Kulwinder Singh; Bhardwaj, Rashmi

    2014-12-01

    This paper deals with water quality management using statistical analysis and time-series prediction model. The monthly variation of water quality standards has been used to compare statistical mean, median, mode, standard deviation, kurtosis, skewness, coefficient of variation at Yamuna River. Model validated using R-squared, root mean square error, mean absolute percentage error, maximum absolute percentage error, mean absolute error, maximum absolute error, normalized Bayesian information criterion, Ljung-Box analysis, predicted value and confidence limits. Using auto regressive integrated moving average model, future water quality parameters values have been estimated. It is observed that predictive model is useful at 95 % confidence limits and curve is platykurtic for potential of hydrogen (pH), free ammonia, total Kjeldahl nitrogen, dissolved oxygen, water temperature (WT); leptokurtic for chemical oxygen demand, biochemical oxygen demand. Also, it is observed that predicted series is close to the original series which provides a perfect fit. All parameters except pH and WT cross the prescribed limits of the World Health Organization /United States Environmental Protection Agency, and thus water is not fit for drinking, agriculture and industrial use.

  1. New calibrators for the Cepheid period-luminosity relation

    NASA Technical Reports Server (NTRS)

    Evans, Nancy R.

    1992-01-01

    IUE spectra of six Cepheids have been used to determine their absolute magnitudes from the spectral types of their binary companions. The stars observed are U Aql, V659 Cen, Y Lac, S Nor, V350 Sgr, and V636 Sco. The absolute magnitude for V659 Cen is more uncertain than for the others because its reddening is poorly determined and the spectral type is hotter than those of the others. In addition, a reddening law with extra absorption in the 2200 A region is necessary, although this has a negligible effect on the absolute magnitude. For the other Cepheids, and also Eta Aql and W Sgr, the standard deviation from the Feast and Walker period-luminosity-color (PLC) relation is 0.37 mag, confirming the previously estimated internal uncertainty. The absolute magnitudes for S Nor from the binary companion and from cluster membership are very similar. The preliminary PLC zero point is less than 2 sigma (+0.21 mag) different from that of Feast and Walker. The same narrowing of the instability strip at low luminosities found by Fernie is seen.

  2. Role of dispersion corrected hybrid GGA class in accurately calculating the bond dissociation energy of carbon halogen bond: A benchmark study

    NASA Astrophysics Data System (ADS)

    Kosar, Naveen; Mahmood, Tariq; Ayub, Khurshid

    2017-12-01

    Benchmark study has been carried out to find a cost effective and accurate method for bond dissociation energy (BDE) of carbon halogen (Csbnd X) bond. BDE of C-X bond plays a vital role in chemical reactions, particularly for kinetic barrier and thermochemistry etc. The compounds (1-16, Fig. 1) with Csbnd X bond used for current benchmark study are important reactants in organic, inorganic and bioorganic chemistry. Experimental data of Csbnd X bond dissociation energy is compared with theoretical results. The statistical analysis tools such as root mean square deviation (RMSD), standard deviation (SD), Pearson's correlation (R) and mean absolute error (MAE) are used for comparison. Overall, thirty-one density functionals from eight different classes of density functional theory (DFT) along with Pople and Dunning basis sets are evaluated. Among different classes of DFT, the dispersion corrected range separated hybrid GGA class along with 6-31G(d), 6-311G(d), aug-cc-pVDZ and aug-cc-pVTZ basis sets performed best for bond dissociation energy calculation of C-X bond. ωB97XD show the best performance with less deviations (RMSD, SD), mean absolute error (MAE) and a significant Pearson's correlation (R) when compared to experimental data. ωB97XD along with Pople basis set 6-311g(d) has RMSD, SD, R and MAE of 3.14 kcal mol-1, 3.05 kcal mol-1, 0.97 and -1.07 kcal mol-1, respectively.

  3. Successful removal of football helmet face-mask clips after 1 season of use.

    PubMed

    Scibek, Jason S; Gatti, Joseph M; McKenzie, Jennifer I

    2012-01-01

    Whereas many researchers have assessed the ability to remove loop straps in traditional face-mask attachment systems after at least 1 season of use, research in which the effectiveness of the Riddell Quick Release (QR) Face Guard Attachment System clip after 1 season has been assessed is limited. To examine the success rate of removing the QR clips after 1 season of use at the Football Championship Subdivision level. We hypothesized that 1 season of use would negatively affect the removal rate of the QR clip but repeated clip-removal trials would improve the removal rate. Retrospective, quasi-experimental design. Controlled laboratory study. Sixty-three football helmets from a National Collegiate Athletic Association Division I university located in western Pennsylvania used during the 2008 season were tested. Three certified athletic trainers (2 men, 1 woman; age = 31.3 ± 3.06 years, time certified = 9.42 ± 2.65 years) attempted to remove the QR clips from each helmet with the tool provided by the manufacturer. Helmets then were reassembled to allow each athletic trainer to attempt clip removal. The dependent variables were total left clips removed (TCR-L), total right clips removed (TCR-R), and total clips removed (TCR). Success rate of clip removal (SRCR) also was assessed. Percentages for TCR-L, TCR-R, and TCR were 100% (189 of 189), 96.30% (182 of 189), and 98.15% (371 of 378), respectively. A paired-samples t test revealed a difference between TCR-R and TCR-L (t(188) = 2.689, P = .008, μ(d) = 0.037, 95% confidence interval [CI] = 0.064, 0.010). The percentage for SRCR was 96.30% (n = 182), whereas SRCR percentages for trials 1, 2, and 3 were 95.24% (n = 60), 98.41% (n = 62), and 95.24% (n = 60), respectively, and did not represent a difference (F(2,186) = 0.588, P = .56, 95% (CI) = 0.94, 0.99). Our results indicated favorable and consistent success rates for QR clip removal after 1 season of use. Whereas the QR clip is an advancement in face-mask technology, continued examination of this system is required to ensure the highest level of function, allowing for effective management of the helmeted athlete.

  4. Successful Removal of Football Helmet Face-Mask Clips After 1 Season of Use

    PubMed Central

    Scibek, Jason S.; Gatti, Joseph M.; McKenzie, Jennifer I.

    2012-01-01

    Context Whereas many researchers have assessed the ability to remove loop straps in traditional face-mask attachment systems after at least 1 season of use, research in which the effectiveness of the Riddell Quick Release (QR) Face Guard Attachment System clip after 1 season has been assessed is limited. Objective To examine the success rate of removing the QR clips after 1 season of use at the Football Championship Subdivision level. We hypothesized that 1 season of use would negatively affect the removal rate of the QR clip but repeated clip-removal trials would improve the removal rate. Design Retrospective, quasi-experimental design. Setting Controlled laboratory study. Patients or Other Participants Sixty-three football helmets from a National Collegiate Athletic Association Division I university located in western Pennsylvania used during the 2008 season were tested. Intervention(s) Three certified athletic trainers (2 men, 1 woman; age = 31.3 ± 3.06 years, time certified = 9.42 ± 2.65 years) attempted to remove the QR clips from each helmet with the tool provided by the manufacturer. Helmets then were reassembled to allow each athletic trainer to attempt clip removal. Main Outcome Measure(s) The dependent variables were total left clips removed (TCR-L), total right clips removed (TCR-R), and total clips removed (TCR). Success rate of clip removal (SRCR) also was assessed. Results Percentages for TCR-L, TCR-R, and TCR were 100% (189 of 189), 96.30% (182 of 189), and 98.15% (371 of 378), respectively. A paired-samples t test revealed a difference between TCR-R and TCR-L (t188 = −2.689, P = .008, μd = 0.037, 95% confidence interval [CI] = −0.064, −0.010). The percentage for SRCR was 96.30% (n = 182), whereas SRCR percentages for trials 1, 2, and 3 were 95.24% (n = 60), 98.41% (n = 62), and 95.24% (n = 60), respectively, and did not represent a difference (F2,186 = 0.588, P = .56, 95% CI = 0.94, 0.99). Conclusions Our results indicated favorable and consistent success rates for QR clip removal after 1 season of use. Whereas the QR clip is an advancement in face-mask technology, continued examination of this system is required to ensure the highest level of function, allowing for effective management of the helmeted athlete. PMID:22889659

  5. Effect of apical meristem clipping on carbon allocation and morphological development of white oak seedlings

    Treesearch

    Paul P. Kormanik; Shi-Jean S. Sung; T.L. Kormanik; Stanley J. Zarnoch

    1994-01-01

    Seedlings from three open-pollinated half-sib white oak seedlots were clipped in mid-July and their development was compared to nonclipped controls after one growing season.In general when data were analyzed by family, clipped seedlings were significantly less desirable in three to six of the eight variables tested.Numerically, in all families seedlots, the clipped...

  6. Clips as a knowledge based language

    NASA Technical Reports Server (NTRS)

    Harrington, James B.

    1987-01-01

    CLIPS is a language for writing expert systems applications on a personal or small computer. Here, the CLIPS programming language is described and compared to three other artificial intelligence (AI) languages (LISP, Prolog, and OPS5) with regard to the processing they provide for the implementation of a knowledge based system (KBS). A discussion is given on how CLIPS would be used in a control system.

  7. Developmental and Behavioral Effects of Toe Clipping on Neonatal and Preweanling Mice with and without Vapocoolant Anesthesia

    PubMed Central

    Paluch, Lee-Ronn; Lieggi, Christine C; Dumont, Magali; Monette, Sebastien; Riedel, Elyn R; Lipman, Neil S

    2014-01-01

    Toe clipping is used to identify and genotype preweanling mice, but the procedure generates concerns relevant to pain and distress. The few pertinent studies available evaluated mice between postnatal days (PND) 3 and 7, advocate the use of toe clipping in mice PND 7 or younger, and identify handling as the most distressing aspect of the procedure. Because both toe and tail clipping may be necessary in older mice to obtain sufficient DNA for genotyping, we surmised that performing these procedures concurrently to minimize handling would be beneficial. We also examined reflex development until PND 21 and adult behavior at 8 to 10 wk of age in mice toe clipped at PND 7 or 17 and the benefits of using topical vapocoolant anesthesia. C57BL/6J pups at PND 7 and 17 were assigned to 1 of 4 groups: 1) clipping of digit 3 of contralateral fore- and hindpaws; 2) toe clipping after topical vapocoolant anesthesia; 3) unclipped, unsprayed controls; and, 4) unclipped and vapocoolant-sprayed. Compared with unanesthetized pups, those sprayed with vapocoolant vocalized and struggled more when handled and had more bleeding, erythema, and swelling, which persisted for as long as 12 h after toe clipping. Reflex development, anxiety, locomotion, and motor coordination were not different among groups or with regard to the age of toe clipping. No tissue reaction was noted microscopically in paws collected at 10 wk of age. We conclude that the use of vapocoolant cannot be recommended due to its harmful effects and that toe clipping at PND 7 or 17 does not significantly affect the long-term welfare of mice. PMID:24602538

  8. Differences in displacement of the proximal and distal ends of mid-upper thoracic esophageal squamous cell carcinoma.

    PubMed

    Qiu, Guoqin; Wen, Dengshun; DU, Xianghui; Sheng, Liming; Zhou, Xia; Ji, Yongling; Bao, Wuan; Zhang, Danhong; Cheng, Lei

    2016-07-01

    In the present study, clips were used as markers to evaluate displacement differences between proximal and distal ends of esophageal tumors and to test whether their internal target volume (ITV) margins should be determined separately. A total of 23 patients with mid-upper thoracic esophageal squamous-cell carcinoma, a tumor length of ≤8 cm and an esophageal lumen suitable for endoscopic ultrasonography were recruited for the present study. Clips were implanted endoscopically at the proximal and distal ends of the esophageal tumor (upper and lower clips). In a further exploratory study on 16 of the patients, a third clip was placed at the distal esophagus 2 cm above the gastro-esophageal junction (GEJ) (cardiac clip). The clips were contoured for all 10 phases of the four-dimensional computed tomography and the maximum displacements of the clip centroids among different breathing phases in left-right (LR), superior-inferior (SI) and anterior-posterior (AP) directions were marked as x, y and z, respectively. The ITV margins that covered 95% of the LR, SI and AP motion were 2.89, 5.00 and 2.36 mm, respectively. Axial displacement (y) was greater than radial displacement (x, z; P<0.05). It was also revealed that LR(x), SI(y) and AP(z) displacement of cardiac clips was greater than that of upper or lower clips (P<0.05). Differences in the axial and radial displacement of the upper and lower clips indicated that axial and radial ITV margins should be determined separately. However, further study is required on patients in whom the distal tumor end is located in proximity to the GEJ.

  9. A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat

    PubMed Central

    Chelko, Stephen P.; Schmiedt, Chad W.; Lewis, Tristan H.; Lewis, Stephen J.

    2012-01-01

    The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40–60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips may also be easily dislodged from the renal artery following placement. Therefore, we designed and tested a novel vascular clip possessing design features to maintain both gap width and position around the renal artery. In this initial study, application of these new clips to the left renal artery produced reliable and consistent levels of hypertension in rats. Nine-day application of clips with gap widths of 0.27, 0.25, and 0.23 mm elicited higher mean arterial blood pressures of 112 ± 4, 121 ± 6, and 135 ± 7 mmHg, respectively (n = 8 for each group), than those of sham-operated controls (95 ± 2 mmHg, n = 8). Moreover, 8 out of 8 rats in each of the 0.23 and 0.25 mm 2K1C groups were hypertensive, whereas 7 out of 8 rats in the 0.27 mm 2K1C group were hypertensive. Plasma renin concentrations were also increased in all 2K1C groups compared with sham-operated controls. In summary, this novel clip design may help eliminate the large degree of unreliability commonly encountered with the 2K1C model. PMID:22074718

  10. A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat.

    PubMed

    Chelko, Stephen P; Schmiedt, Chad W; Lewis, Tristan H; Lewis, Stephen J; Robertson, Tom P

    2012-02-01

    The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40-60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips may also be easily dislodged from the renal artery following placement. Therefore, we designed and tested a novel vascular clip possessing design features to maintain both gap width and position around the renal artery. In this initial study, application of these new clips to the left renal artery produced reliable and consistent levels of hypertension in rats. Nine-day application of clips with gap widths of 0.27, 0.25, and 0.23 mm elicited higher mean arterial blood pressures of 112 ± 4, 121 ± 6, and 135 ± 7 mmHg, respectively (n = 8 for each group), than those of sham-operated controls (95 ± 2 mmHg, n = 8). Moreover, 8 out of 8 rats in each of the 0.23 and 0.25 mm 2K1C groups were hypertensive, whereas 7 out of 8 rats in the 0.27 mm 2K1C group were hypertensive. Plasma renin concentrations were also increased in all 2K1C groups compared with sham-operated controls. In summary, this novel clip design may help eliminate the large degree of unreliability commonly encountered with the 2K1C model.

  11. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (UNIX VERSION)

    NASA Technical Reports Server (NTRS)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.

  12. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (IBM PC VERSION)

    NASA Technical Reports Server (NTRS)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.

  13. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (MACINTOSH VERSION)

    NASA Technical Reports Server (NTRS)

    Riley, G.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.

  14. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (DEC VAX VMS VERSION)

    NASA Technical Reports Server (NTRS)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.

  15. Plastic bag clip discovered in partial colectomy accompanying proposal for phylogenic plastic bag clip classification

    PubMed Central

    Lehmer, Larisa M; Ragsdale, Bruce D; Daniel, John; Hayashi, Edwin; Kvalstad, Robert

    2011-01-01

    A plastic bag clip was incidentally found anchored in the mucosa of a partial colectomy specimen 2.6 cm proximal to a ruptured diverticulum for which the patient, a mentally retarded, diabetic, 58-year-old man, underwent surgery. Over 20 cases of accidental ingestion of plastic bag clips have been published. Known complications include small bowel perforation, obstruction, dysphagia, gastrointestinal bleeding and colonic impaction. Preoperative diagnosis of plastic clips lodged in the gastrointestinal tract is frustrated due to radiographic translucency. This occult threat could likely be prevented by the design of gastrointestinally safe, plastic-bag-sealing devices. Presented here is a morphologically based classification of bag clips as a possible guide for determining the most hazardous varieties and to aid further discussions of their impact on health. PMID:22679182

  16. CLIPS interface development tools and their application

    NASA Technical Reports Server (NTRS)

    Engel, Bernard A.; Rewerts, Chris C.; Srinivasan, Raghavan; Rogers, Joseph B.; Jones, Don D.

    1990-01-01

    A package of C-based PC user interface development functions has been developed and integrated into CLIPS. The primary function is ASK which provides a means to ask the user questions via multiple choice menus or the keyboard and then returns the user response to CLIPS. A parameter-like structure supplies information for the interface. Another function, SHOW, provides a means to paginate and display text. A third function, TITLE, formats and displays title screens. A similar set of C-based functions that are more general and thus will run on UNIX and machines have also been developed. Seven expert system applications were transformed from commercial development environments into CLIPS and utilize ASK, SHOW, and TITLE. Development of numerous new expert system applications using CLIPS and these interface functions has started. These functions greatly reduce the time required to build interfaces for CLIPS applications.

  17. Effects of Japanese beetle (Coleoptera: Scarabaeidae) and silk clipping in field corn.

    PubMed

    Steckel, Sandy; Stewart, S D; Tindall, K V

    2013-10-01

    Japanese beetle (Popillia japonica Newman) is an emerging silk-feeding insect found in fields in the lower Corn Belt and Midsouthern United States. Studies were conducted in 2010 and 2011 to evaluate how silk clipping in corn affects pollination and yield parameters. Manually clipping silks once daily had modest effects on yield parameters. Sustained clipping by either manually clipping silks three times per day or by caging Japanese beetles onto ears affected total kernel weight if it occurred during early silking (R1 growth stage). Manually clipping silks three times per day for the first 5 d of silking affected the number of kernels per ear, total kernel weight, and the weight of individual kernels. Caged beetles fed on silks and, depending on the number of beetles caged per ear, reduced the number of kernels per ear. Caging eight beetles per ear significantly reduced total kernel weight compared with noninfested ears. Drought stress before anthesis appeared to magnify the impact of silk clipping by Japanese beetles. There was evidence of some compensation for reduced pollination by increasing the size of pollinated kernels within the ear. Our results showed that it requires sustained silk clipping during the first week of silking to have substantial impacts on pollination and yield parameters, at least under good growing conditions. Some states recommend treating for Japanese beetle when three Japanese beetles per ear are found, silks are clipped to < 13 mm, and pollination is < 50% complete, and that recommendation appears to be adequate.

  18. Suture retraction technique to prevent parent vessel obstruction following aneurysm tandem clipping.

    PubMed

    Rayan, Tarek; Amin-Hanjani, Sepideh

    2015-08-01

    With large or giant aneurysms, the use of multiple tandem clips can be essential for complete obliteration of the aneurysm. One potential disadvantage, however, is the considerable cumulative weight of these clips, which may lead to kinking of the underlying parent vessels and obstruction of flow. The authors describe a simple technique to address this problem, guided by intraoperative blood flow measurements, in a patient with a ruptured near-giant 2.2 × 1.7-cm middle cerebral artery bifurcation aneurysm that was treated with the tandem clipping technique. A total of 11 clips were applied in a vertical stacked fashion. The cumulative weight of the clips caused kinking of the temporal M2 branch of the bifurcation with reduction of flow. A 4-0 Nurolon suture tie was applied to the hub of one of the clips and was tethered to the dura of the sphenoid ridge by a small mini-clip and reinforced by application of tissue sealant. The patient underwent intraoperative indocyanine green videoangiography as well as catheter angiography, which demonstrated complete aneurysmal obliteration and preservation of vessel branches. Postoperative angiography confirmed patency of the bifurcation vessels with mild vasospasm. The patient had a full recovery with no postoperative complications and was neurologically intact at her 6-month follow-up. The suture retraction technique allows a simple solution to parent vessel obstruction following aneurysm tandem clipping, in conjunction with the essential guidance provided by intraoperative flow measurements.

  19. Expert system technologies for Space Shuttle decision support: Two case studies

    NASA Technical Reports Server (NTRS)

    Ortiz, Christopher J.; Hasan, David A.

    1994-01-01

    This paper addresses the issue of integrating the C Language Integrated Production System (CLIPS) into distributed data acquisition environments. In particular, it presents preliminary results of some ongoing software development projects aimed at exploiting CLIPS technology in the new mission control center (MCC) being built at NASA Johnson Space Center. One interesting aspect of the control center is its distributed architecture; it consists of networked workstations which acquire and share data through the NASA/JSC-developed information sharing protocol (ISP). This paper outlines some approaches taken to integrate CLIPS and ISP in order to permit the development of intelligent data analysis applications which can be used in the MCC. Three approaches to CLIPS/IPS integration are discussed. The initial approach involves clearly separating CLIPS from ISP using user-defined functions for gathering and sending data to and from a local storage buffer. Memory and performance drawbacks of this design are summarized. The second approach involves taking full advantage of CLIPS and the CLIPS Object-Oriented Language (COOL) by using objects to directly transmit data and state changes from ISP to COOL. Any changes within the object slots eliminate the need for both a data structure and external function call thus taking advantage of the object matching capabilities within CLIPS 6.0. The final approach is to treat CLIPS and ISP as peer toolkits. Neither is embedded in the other; rather the application interweaves calls to each directly in the application source code.

  20. Retractable pin dual in-line package test clip

    DOEpatents

    Bandzuch, Gregory S.; Kosslow, William J.

    1996-01-01

    This invention is a Dual In-Line Package (DIP) test clip for use when troubleshooting circuits containing DIP integrated circuits. This test clip is a significant improvement over existing DIP test clips in that it has retractable pins which will permit troubleshooting without risk of accidentally shorting adjacent pins together when moving probes to different pins on energized circuits or when the probe is accidentally bumped while taking measurements.

  1. Forecasting of Water Consumptions Expenditure Using Holt-Winter’s and ARIMA

    NASA Astrophysics Data System (ADS)

    Razali, S. N. A. M.; Rusiman, M. S.; Zawawi, N. I.; Arbin, N.

    2018-04-01

    This study is carried out to forecast water consumption expenditure of Malaysian university specifically at University Tun Hussein Onn Malaysia (UTHM). The proposed Holt-Winter’s and Auto-Regressive Integrated Moving Average (ARIMA) models were applied to forecast the water consumption expenditure in Ringgit Malaysia from year 2006 until year 2014. The two models were compared and performance measurement of the Mean Absolute Percentage Error (MAPE) and Mean Absolute Deviation (MAD) were used. It is found that ARIMA model showed better results regarding the accuracy of forecast with lower values of MAPE and MAD. Analysis showed that ARIMA (2,1,4) model provided a reasonable forecasting tool for university campus water usage.

  2. MetaMQAP: a meta-server for the quality assessment of protein models.

    PubMed

    Pawlowski, Marcin; Gajda, Michal J; Matlak, Ryszard; Bujnicki, Janusz M

    2008-09-29

    Computational models of protein structure are usually inaccurate and exhibit significant deviations from the true structure. The utility of models depends on the degree of these deviations. A number of predictive methods have been developed to discriminate between the globally incorrect and approximately correct models. However, only a few methods predict correctness of different parts of computational models. Several Model Quality Assessment Programs (MQAPs) have been developed to detect local inaccuracies in unrefined crystallographic models, but it is not known if they are useful for computational models, which usually exhibit different and much more severe errors. The ability to identify local errors in models was tested for eight MQAPs: VERIFY3D, PROSA, BALA, ANOLEA, PROVE, TUNE, REFINER, PROQRES on 8251 models from the CASP-5 and CASP-6 experiments, by calculating the Spearman's rank correlation coefficients between per-residue scores of these methods and local deviations between C-alpha atoms in the models vs. experimental structures. As a reference, we calculated the value of correlation between the local deviations and trivial features that can be calculated for each residue directly from the models, i.e. solvent accessibility, depth in the structure, and the number of local and non-local neighbours. We found that absolute correlations of scores returned by the MQAPs and local deviations were poor for all methods. In addition, scores of PROQRES and several other MQAPs strongly correlate with 'trivial' features. Therefore, we developed MetaMQAP, a meta-predictor based on a multivariate regression model, which uses scores of the above-mentioned methods, but in which trivial parameters are controlled. MetaMQAP predicts the absolute deviation (in Angströms) of individual C-alpha atoms between the model and the unknown true structure as well as global deviations (expressed as root mean square deviation and GDT_TS scores). Local model accuracy predicted by MetaMQAP shows an impressive correlation coefficient of 0.7 with true deviations from native structures, a significant improvement over all constituent primary MQAP scores. The global MetaMQAP score is correlated with model GDT_TS on the level of 0.89. Finally, we compared our method with the MQAPs that scored best in the 7th edition of CASP, using CASP7 server models (not included in the MetaMQAP training set) as the test data. In our benchmark, MetaMQAP is outperformed only by PCONS6 and method QA_556 - methods that require comparison of multiple alternative models and score each of them depending on its similarity to other models. MetaMQAP is however the best among methods capable of evaluating just single models. We implemented the MetaMQAP as a web server available for free use by all academic users at the URL https://genesilico.pl/toolkit/

  3. Advanced CLIPS capabilities

    NASA Technical Reports Server (NTRS)

    Riley, Gary

    1991-01-01

    The C Language Integrated Production System (CLIPS) is a forward chaining rule based language developed by NASA. CLIPS was designed specifically to provide high portability, low cost, and easy integration with external systems. The current release of CLIPS, version 4.3, is being used by over 2500 users throughout the public and private community. The primary addition to the next release of CLIPS, version 5.0, will be the CLIPS Object Oriented Language (COOL). The major capabilities of COOL are: class definition with multiple inheritance and no restrictions on the number, types, or cardinality of slots; message passing which allows procedural code bundled with an object to be executed; and query functions which allow groups of instances to be examined and manipulated. In addition to COOL, numerous other enhancements were added to CLIPS including: generic functions (which allow different pieces of procedural code to be executed depending upon the types or classes of the arguments); integer and double precision data type support; multiple conflict resolution strategies; global variables; logical dependencies; type checking on facts; full ANSI compiler support; and incremental reset for rules.

  4. Clipping in neurocontrol by adaptive dynamic programming.

    PubMed

    Fairbank, Michael; Prokhorov, Danil; Alonso, Eduardo

    2014-10-01

    In adaptive dynamic programming, neurocontrol, and reinforcement learning, the objective is for an agent to learn to choose actions so as to minimize a total cost function. In this paper, we show that when discretized time is used to model the motion of the agent, it can be very important to do clipping on the motion of the agent in the final time step of the trajectory. By clipping, we mean that the final time step of the trajectory is to be truncated such that the agent stops exactly at the first terminal state reached, and no distance further. We demonstrate that when clipping is omitted, learning performance can fail to reach the optimum, and when clipping is done properly, learning performance can improve significantly. The clipping problem we describe affects algorithms that use explicit derivatives of the model functions of the environment to calculate a learning gradient. These include backpropagation through time for control and methods based on dual heuristic programming. However, the clipping problem does not significantly affect methods based on heuristic dynamic programming, temporal differences learning, or policy-gradient learning algorithms.

  5. Diffuse ultraviolet erythemal irradiance on inclined planes: a comparison of experimental and modeled data.

    PubMed

    Utrillas, María P; Marín, María J; Esteve, Anna R; Estellés, Victor; Tena, Fernando; Cañada, Javier; Martínez-Lozano, José A

    2009-01-01

    Values of measured and modeled diffuse UV erythemal irradiance (UVER) for all sky conditions are compared on planes inclined at 40 degrees and oriented north, south, east and west. The models used for simulating diffuse UVER are of the geometric-type, mainly the Isotropic, Klucher, Hay, Muneer, Reindl and Schauberger models. To analyze the precision of the models, some statistical estimators were used such as root mean square deviation, mean absolute deviation and mean bias deviation. It was seen that all the analyzed models reproduce adequately the diffuse UVER on the south-facing plane, with greater discrepancies for the other inclined planes. When the models are applied to cloud-free conditions, the errors obtained are higher because the anisotropy of the sky dome acquires more importance and the models do not provide the estimation of diffuse UVER accurately.

  6. [Influence of human personal features on acoustic correlates of speech emotional intonation characteristics].

    PubMed

    Dmitrieva, E S; Gel'man, V Ia; Zaĭtseva, K A; Orlov, A M

    2009-01-01

    Comparative study of acoustic correlates of emotional intonation was conducted on two types of speech material: sensible speech utterances and short meaningless words. The corpus of speech signals of different emotional intonations (happy, angry, frightened, sad and neutral) was created using the actor's method of simulation of emotions. Native Russian 20-70-year-old speakers (both professional actors and non-actors) participated in the study. In the corpus, the following characteristics were analyzed: mean values and standard deviations of the power, fundamental frequency, frequencies of the first and second formants, and utterance duration. Comparison of each emotional intonation with "neutral" utterances showed the greatest deviations of the fundamental frequency and frequencies of the first formant. The direction of these deviations was independent of the semantic content of speech utterance and its duration, age, gender, and being actor or non-actor, though the personal features of the speakers affected the absolute values of these frequencies.

  7. Vapor-liquid equilibria for an R134a/lubricant mixture: Measurements and equation-of-state modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huber, M.L.; Holcomb, C.D.; Outcalt, S.L.

    2000-07-01

    The authors measured bubble point pressures and coexisting liquid densities for two mixtures of R-134a and a polyolester (POE) lubricant. The mass fraction of the lubricant was approximately 9% and 12%, and the temperature ranged from 280 K to 355 K. The authors used the Elliott, Suresh, and Donohue (ESD) equation of state to model the bubble point pressure data. The bubble point pressures were represented with an average absolute deviation of 2.5%. A binary interaction parameter reduced the deviation to 1.4%. The authors also applied the ESD model to other R-134a/POE lubricant data in the literature. As the concentrationmore » of the lubricant increased, the performance of the model deteriorated markedly. However, the use of a single binary interaction parameter reduced the deviations significantly.« less

  8. A Case Study to Improve Emergency Room Patient Flow at Womack Army Medical Center

    DTIC Science & Technology

    2009-06-01

    use just the previous month, moving average 2-month period ( MA2 ) uses the average from the previous two months, moving average 3-month period (MA3...ED prior to discharge by provider) MA2 /MA3/MA4 - moving averages of 2-4 months in length MAD - mean absolute deviation (measure of accuracy for

  9. Observations on the method of determining the velocity of airships

    NASA Technical Reports Server (NTRS)

    Volterra, Vito

    1921-01-01

    To obtain the absolute velocity of an airship by knowing the speed at which two routes are covered, we have only to determine the geographical direction of the routes which we locate from a map, and the angles of routes as given by the compass, after correcting for the variation (the algebraical sum of the local magnetic declination and the deviation).

  10. File Carving and Malware Identification Algorithms Applied to Firmware Reverse Engineering

    DTIC Science & Technology

    2013-03-21

    33 3.5 Performance Metrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 3.6 Experimental...consider a byte value rate-of-change frequency metric [32]. Their system calculates the absolute value of the distance between all consecutive bytes, then...the rate-of-change means and standard deviations. Karresand and Shahmehri use the same distance metric for both byte value frequency and rate-of-change

  11. Film clips and narrative text as subjective emotion elicitation techniques.

    PubMed

    Zupan, Barbra; Babbage, Duncan R

    2017-01-01

    Film clips and narrative text are useful techniques in eliciting emotion in a laboratory setting but have not been examined side-by-side using the same methodology. This study examined the self-identification of emotions elicited by film clip and narrative text stimuli to confirm that selected stimuli appropriately target the intended emotions. Seventy participants viewed 30 film clips, and 40 additional participants read 30 narrative texts. Participants identified the emotion experienced (happy, sad, angry, fearful, neutral-six stimuli each). Eighty-five percent of participants self-identified the target emotion for at least two stimuli for all emotion categories of film clips, except angry (only one) and for all categories of narrative text, except fearful (only one). The most effective angry text was correctly identified 74% of the time. Film clips were more effective in eliciting all target emotions in participants for eliciting the correct emotion (angry), intensity rating (happy, sad), or both (fearful).

  12. Mounting clips for panel installation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    2017-02-14

    An exemplary mounting clip for removably attaching panels to a supporting structure comprises a base, spring locking clips, a lateral flange, a lever flange, and a spring bonding pad. The spring locking clips extend upwardly from the base. The lateral flange extends upwardly from a first side of the base. The lateral flange comprises a slot having an opening configured to receive at least a portion of one of the one or more panels. The lever flange extends outwardly from the lateral flange. The spring bonding flange extends downwardly from the lever flange. At least a portion of the firstmore » spring bonding flange comprises a serrated edge for gouging at least a portion of the one or more panels when the one or more panels are attached to the mounting clip to electrically and mechanically couple the one or more panels to the mounting clip.« less

  13. The use of video clips in teleconsultation for preschool children with movement disorders.

    PubMed

    Gorter, Hetty; Lucas, Cees; Groothuis-Oudshoorn, Karin; Maathuis, Carel; van Wijlen-Hempel, Rietje; Elvers, Hans

    2013-01-01

    To investigate the reliability and validity of video clips in assessing movement disorders in preschool children. The study group included 27 children with neuromotor concerns. The explorative validity group included children with motor problems (n = 21) or with typical development (n = 9). Hempel screening was used for live observation of the child, full recording, and short video clips. The explorative study tested the validity of the clinical classifications "typical" or "suspect." Agreement between live observation and the full recording was almost perfect; Agreement for the clinical classification "typical" or "suspect" was substantial. Agreement between the full recording and short video clips was substantial to moderate. The explorative validity study, based on short video clips and the presence of a neuromotor developmental disorder, showed substantial agreement. Hempel screening enables reliable and valid observation of video clips, but further research is necessary to demonstrate the predictive value.

  14. Embedding CLIPS in a database-oriented diagnostic system

    NASA Technical Reports Server (NTRS)

    Conway, Tim

    1990-01-01

    This paper describes the integration of C Language Production Systems (CLIPS) into a powerful portable maintenance aid (PMA) system used for flightline diagnostics. The current diagnostic target of the system is the Garrett GTCP85-180L, a gas turbine engine used as an Auxiliary Power Unit (APU) on some C-130 military transport aircraft. This project is a database oriented approach to a generic diagnostic system. CLIPS is used for 'many-to-many' pattern matching within the diagnostics process. Patterns are stored in database format, and CLIPS code is generated by a 'compilation' process on the database. Multiple CLIPS rule sets and working memories (in sequence) are supported and communication between the rule sets is achieved via the export and import commands. Work is continuing on using CLIPS in other portions of the diagnostic system and in re-implementing the diagnostic system in the Ada language.

  15. Development of a Dual-Pump CARS System for Measurements in a Supersonic Combusting Free Jet

    NASA Technical Reports Server (NTRS)

    Magnotti, Gaetano; Cutler, Andrew D.; Danehy, Paul

    2012-01-01

    This work describes the development of a dual-pump CARS system for simultaneous measurements of temperature and absolute mole fraction of N2, O2 and H2 in a laboratory scale supersonic combusting free jet. Changes to the experimental set-up and the data analysis to improve the quality of the measurements in this turbulent, high-temperature reacting flow are described. The accuracy and precision of the instrument have been determined using data collected in a Hencken burner flame. For temperature above 800 K, errors in absolute mole fraction are within 1.5, 0.5, and 1% of the total composition for N2, O2 and H2, respectively. Estimated standard deviations based on 500 single shots are between 10 and 65 K for the temperature, between 0.5 and 1.7% of the total composition for O2, and between 1.5 and 3.4% for N2. The standard deviation of H2 is 10% of the average measured mole fraction. Results obtained in the jet with and without combustion are illustrated, and the capabilities and limitations of the dual-pump CARS instrument discussed.

  16. Modelling PET radionuclide production in tissue and external targets using Geant4

    NASA Astrophysics Data System (ADS)

    Amin, T.; Infantino, A.; Lindsay, C.; Barlow, R.; Hoehr, C.

    2017-07-01

    The Proton Therapy Facility in TRIUMF provides 74 MeV protons extracted from a 500 MeV H- cyclotron for ocular melanoma treatments. During treatment, positron emitting radionuclides such as 1C, 15O and 13N are produced in patient tissue. Using PET scanners, the isotopic activity distribution can be measured for in-vivo range verification. A second cyclotron, the TR13, provides 13 MeV protons onto liquid targets for the production of PET radionuclides such as 18F, 13N or 68Ga, for medical applications. The aim of this work was to validate Geant4 against FLUKA and experimental measurements for production of the above-mentioned isotopes using the two cyclotrons. The results show variable degrees of agreement. For proton therapy, the proton-range agreement was within 2 mm for 11C activity, whereas 13N disagreed. For liquid targets at the TR13 the average absolute deviation ratio between FLUKA and experiment was 1.9±2.7, whereas the average absolute deviation ratio between Geant4 and experiment was 0. 6±0.4. This is due to the uncertainties present in experimentally determined reaction cross sections.

  17. Patient with oligodontia treated with a miniscrew for unilateral mesial movement of the maxillary molars and alignment of an impacted third molar.

    PubMed

    Maeda, Aya; Sakoguchi, Yoko; Miyawaki, Shouichi

    2013-09-01

    This report describes the treatment of a 20-year-old woman with a dental midline deviation and 7 congenitally missing premolars. She had retained a maxillary right deciduous canine and 4 deciduous second molars, and she had an impacted maxillary right third molar. The maxillary right deciduous second molar was extracted, and the space was nearly closed by mesial movement of the maxillary right molars using an edgewise appliance and a miniscrew for absolute anchorage. The miniscrew was removed, and the extraction space of the maxillary right deciduous canine was closed, correcting the dental midline deviation. After the mesial movement of the maxillary right molars, the impacted right third molar was aligned. To prevent root resorption, the retained left deciduous second molars were not aligned by the edgewise appliance. The occlusal contact area and the maximum occlusal force increased over the 2 years of retention. The miniscrew was useful for absolute anchorage for unilateral mesial movement of the maxillary molars and for the creation of eruption space and alignment of the impacted third molar in a patient with oligodontia. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  18. Assessing arsenic and selenium in a single nail clipping using portable X-ray fluorescence.

    PubMed

    Fleming, David E B; Nader, Michel N; Foran, Kelly A; Groskopf, Craig; Reno, Michael C; Ware, Chris S; Tehrani, Mina; Guimarães, Diana; Parsons, Patrick J

    2017-02-01

    The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic K α , selenium K α , arsenic K β , selenium K β , and bromine K α characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the K α peak only, ranged from 0.210±0.002µg/g selenium under one condition of analysis to 0.777±0.009µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Mitral stenosis due to dynamic clip-leaflet interaction during the MitraClip procedure: Case report and review of current knowledge.

    PubMed

    Singh, Gagan D; Smith, Thomas W; Rogers, Jason H

    2017-06-01

    The goal of MitraClip therapy is to achieve mitral regurgitation reduction without iatrogenic creation of clinically significant MS. In some series, up to 35% of patients are left with mild MS. There are many contributors to the final transmitral gradient achieved in patients undergoing MitraClip therapy. Additionally, there are many modalities used for the intraprocedural assessment of MS with no one modality considered to be the benchmark. We herein describe a case which illustrates the dynamic nature of clip-leaflet interaction, and review intraprocedural techniques for invasively and noninvasively assessing MS. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Preparation of digital movie clips for online journal publication.

    PubMed

    Yam, Chun-Shan

    2006-07-01

    This article presents general guidelines for preparing movie clips for online journal publication. As more and more radiology journals establish an online presence, radiologists wishing to submit journal articles with movie clips need to understand the electronic submission process. Viewing a movie clip via an online journal is different from viewing one with PowerPoint using a local desktop computer because the movie file must first be downloaded onto the client computer before it can be displayed. Users thus should be cautious in selecting movie format and compression when creating movie clips for online journals. This article provides step-by-step demonstrations and general guidelines for movie format and compression selections.

  1. CLIPS: A tool for corn disease diagnostic system and an aid to neural network for automated knowledge acquisition

    NASA Technical Reports Server (NTRS)

    Wu, Cathy; Taylor, Pam; Whitson, George; Smith, Cathy

    1990-01-01

    This paper describes the building of a corn disease diagnostic expert system using CLIPS, and the development of a neural expert system using the fact representation method of CLIPS for automated knowledge acquisition. The CLIPS corn expert system diagnoses 21 diseases from 52 symptoms and signs with certainty factors. CLIPS has several unique features. It allows the facts in rules to be broken down to object-attribute-value (OAV) triples, allows rule-grouping, and fires rules based on pattern-matching. These features combined with the chained inference engine result to a natural user query system and speedy execution. In order to develop a method for automated knowledge acquisition, an Artificial Neural Expert System (ANES) is developed by a direct mapping from the CLIPS system. The ANES corn expert system uses the same OAV triples in the CLIPS system for its facts. The LHS and RHS facts of the CLIPS rules are mapped into the input and output layers of the ANES, respectively; and the inference engine of the rules is imbedded in the hidden layer. The fact representation by OAC triples gives a natural grouping of the rules. These features allow the ANES system to automate rule-generation, and make it efficient to execute and easy to expand for a large and complex domain.

  2. Laser frequency stabilization using a commercial wavelength meter

    NASA Astrophysics Data System (ADS)

    Couturier, Luc; Nosske, Ingo; Hu, Fachao; Tan, Canzhu; Qiao, Chang; Jiang, Y. H.; Chen, Peng; Weidemüller, Matthias

    2018-04-01

    We present the characterization of a laser frequency stabilization scheme using a state-of-the-art wavelength meter based on solid Fizeau interferometers. For a frequency-doubled Ti-sapphire laser operated at 461 nm, an absolute Allan deviation below 10-9 with a standard deviation of 1 MHz over 10 h is achieved. Using this laser for cooling and trapping of strontium atoms, the wavemeter scheme provides excellent stability in single-channel operation. Multi-channel operation with a multimode fiber switch results in fluctuations of the atomic fluorescence correlated to residual frequency excursions of the laser. The wavemeter-based frequency stabilization scheme can be applied to a wide range of atoms and molecules for laser spectroscopy, cooling, and trapping.

  3. Estimating error statistics for Chambon-la-Forêt observatory definitive data

    NASA Astrophysics Data System (ADS)

    Lesur, Vincent; Heumez, Benoît; Telali, Abdelkader; Lalanne, Xavier; Soloviev, Anatoly

    2017-08-01

    We propose a new algorithm for calibrating definitive observatory data with the goal of providing users with estimates of the data error standard deviations (SDs). The algorithm has been implemented and tested using Chambon-la-Forêt observatory (CLF) data. The calibration process uses all available data. It is set as a large, weakly non-linear, inverse problem that ultimately provides estimates of baseline values in three orthogonal directions, together with their expected standard deviations. For this inverse problem, absolute data error statistics are estimated from two series of absolute measurements made within a day. Similarly, variometer data error statistics are derived by comparing variometer data time series between different pairs of instruments over few years. The comparisons of these time series led us to use an autoregressive process of order 1 (AR1 process) as a prior for the baselines. Therefore the obtained baselines do not vary smoothly in time. They have relatively small SDs, well below 300 pT when absolute data are recorded twice a week - i.e. within the daily to weekly measures recommended by INTERMAGNET. The algorithm was tested against the process traditionally used to derive baselines at CLF observatory, suggesting that statistics are less favourable when this latter process is used. Finally, two sets of definitive data were calibrated using the new algorithm. Their comparison shows that the definitive data SDs are less than 400 pT and may be slightly overestimated by our process: an indication that more work is required to have proper estimates of absolute data error statistics. For magnetic field modelling, the results show that even on isolated sites like CLF observatory, there are very localised signals over a large span of temporal frequencies that can be as large as 1 nT. The SDs reported here encompass signals of a few hundred metres and less than a day wavelengths.

  4. Comparison of absolute gain photometric calibration between Planck/HFI and Herschel/SPIRE at 545 and 857 GHz

    NASA Astrophysics Data System (ADS)

    Bertincourt, B.; Lagache, G.; Martin, P. G.; Schulz, B.; Conversi, L.; Dassas, K.; Maurin, L.; Abergel, A.; Beelen, A.; Bernard, J.-P.; Crill, B. P.; Dole, H.; Eales, S.; Gudmundsson, J. E.; Lellouch, E.; Moreno, R.; Perdereau, O.

    2016-04-01

    We compare the absolute gain photometric calibration of the Planck/HFI and Herschel/SPIRE instruments on diffuse emission. The absolute calibration of HFI and SPIRE each relies on planet flux measurements and comparison with theoretical far-infrared emission models of planetary atmospheres. We measure the photometric cross calibration between the instruments at two overlapping bands, 545 GHz/500 μm and 857 GHz/350 μm. The SPIRE maps used have been processed in the Herschel Interactive Processing Environment (Version 12) and the HFI data are from the 2015 Public Data Release 2. For our study we used 15 large fields observed with SPIRE, which cover a total of about 120 deg2. We have selected these fields carefully to provide high signal-to-noise ratio, avoid residual systematics in the SPIRE maps, and span a wide range of surface brightness. The HFI maps are bandpass-corrected to match the emission observed by the SPIRE bandpasses. The SPIRE maps are convolved to match the HFI beam and put on a common pixel grid. We measure the cross-calibration relative gain between the instruments using two methods in each field, pixel-to-pixel correlation and angular power spectrum measurements. The SPIRE/HFI relative gains are 1.047 (±0.0069) and 1.003 (±0.0080) at 545 and 857 GHz, respectively, indicating very good agreement between the instruments. These relative gains deviate from unity by much less than the uncertainty of the absolute extended emission calibration, which is about 6.4% and 9.5% for HFI and SPIRE, respectively, but the deviations are comparable to the values 1.4% and 5.5% for HFI and SPIRE if the uncertainty from models of the common calibrator can be discounted. Of the 5.5% uncertainty for SPIRE, 4% arises from the uncertainty of the effective beam solid angle, which impacts the adopted SPIRE point source to extended source unit conversion factor, highlighting that as a focus for refinement.

  5. What kind of erotic film clips should we use in female sex research? An exploratory study.

    PubMed

    Woodard, Terri L; Collins, Karen; Perez, Mindy; Balon, Richard; Tancer, Manuel E; Kruger, Michael; Moffat, Scott; Diamond, Michael P

    2008-01-01

    Erotic film clips are used in sex research, including studies of female sexual dysfunction and arousal. However, little is known about which clips optimize female sexual response. Furthermore, their use is not well standardized. To identify the types of film clips that are most mentally appealing and physically arousing to women for use in future sexual function and dysfunction studies; to explore the relationship between mental appeal and reported physical arousal; to characterize the content of the films that were found to be the most and least appealing and arousing. Twenty-one women viewed 90 segments of erotic film clips. They rated how (i) mentally appealing and (ii) how physically aroused they were by each clip. The data were analyzed by descriptive statistics. The means of the mental and self-reported physical responses were calculated to determine the most and least appealing/arousing film clips. Pearson correlations were calculated to assess the relationship between mental appeal and reported physical arousal. Self-reported mental and physical arousal. Of 90 film clips, 18 were identified as the most mentally appealing and physically arousing while nine were identified as the least mentally appealing and physically arousing. The level of mental appeal positively correlated with the level of perceived physical arousal in both categories (r = 0.61, P < 0.05 and r = 0.62, P < 0.05). The most appealing and physically arousing films tended to exhibit heterosexual behavior with vaginal intercourse. The least appealing and least physically arousing films tended to depict male homosexual behavior, fellatio, and anal intercourse. Erotic film clips reliably produced a state of self-reported arousal in women. The most appealing and arousing films tended to depict heterosexual vaginal intercourse. Film clips with these attributes should be used in future research of sexual function and response of women.

  6. LD-SPatt: large deviations statistics for patterns on Markov chains.

    PubMed

    Nuel, G

    2004-01-01

    Statistics on Markov chains are widely used for the study of patterns in biological sequences. Statistics on these models can be done through several approaches. Central limit theorem (CLT) producing Gaussian approximations are one of the most popular ones. Unfortunately, in order to find a pattern of interest, these methods have to deal with tail distribution events where CLT is especially bad. In this paper, we propose a new approach based on the large deviations theory to assess pattern statistics. We first recall theoretical results for empiric mean (level 1) as well as empiric distribution (level 2) large deviations on Markov chains. Then, we present the applications of these results focusing on numerical issues. LD-SPatt is the name of GPL software implementing these algorithms. We compare this approach to several existing ones in terms of complexity and reliability and show that the large deviations are more reliable than the Gaussian approximations in absolute values as well as in terms of ranking and are at least as reliable as compound Poisson approximations. We then finally discuss some further possible improvements and applications of this new method.

  7. Linking Comparisons of Absolute Gravimeters: A Proof of Concept for a new Global Absolute Gravity Reference System.

    NASA Astrophysics Data System (ADS)

    Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.

    2016-12-01

    Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.

  8. Beyond δ : Tailoring marked statistics to reveal modified gravity

    NASA Astrophysics Data System (ADS)

    Valogiannis, Georgios; Bean, Rachel

    2018-01-01

    Models that seek to explain cosmic acceleration through modifications to general relativity (GR) evade stringent Solar System constraints through a restoring, screening mechanism. Down-weighting the high-density, screened regions in favor of the low density, unscreened ones offers the potential to enhance the amount of information carried in such modified gravity models. In this work, we assess the performance of a new "marked" transformation and perform a systematic comparison with the clipping and logarithmic transformations, in the context of Λ CDM and the symmetron and f (R ) modified gravity models. Performance is measured in terms of the fractional boost in the Fisher information and the signal-to-noise ratio (SNR) for these models relative to the statistics derived from the standard density distribution. We find that all three statistics provide improved Fisher boosts over the basic density statistics. The model parameters for the marked and clipped transformation that best enhance signals and the Fisher boosts are determined. We also show that the mark is useful both as a Fourier and real-space transformation; a marked correlation function also enhances the SNR relative to the standard correlation function, and can on mildly nonlinear scales show a significant difference between the Λ CDM and the modified gravity models. Our results demonstrate how a series of simple analytical transformations could dramatically increase the predicted information extracted on deviations from GR, from large-scale surveys, and give the prospect for a much more feasible potential detection.

  9. Virtual tape measure for the operating microscope: system specifications and performance evaluation.

    PubMed

    Kim, M Y; Drake, J M; Milgram, P

    2000-01-01

    The Virtual Tape Measure for the Operating Microscope (VTMOM) was created to assist surgeons in making accurate 3D measurements of anatomical structures seen in the surgical field under the operating microscope. The VTMOM employs augmented reality techniques by combining stereoscopic video images with stereoscopic computer graphics, and functions by relying on an operator's ability to align a 3D graphic pointer, which serves as the end-point of the virtual tape measure, with designated locations on the anatomical structure being measured. The VTMOM was evaluated for its baseline and application performances as well as its application efficacy. Baseline performance was determined by measuring the mean error (bias) and standard deviation of error (imprecision) in measurements of non-anatomical objects. Application performance was determined by comparing the error in measuring the dimensions of aneurysm models with and without the VTMOM. Application efficacy was determined by comparing the error in selecting the appropriate aneurysm clip size with and without the VTMOM. Baseline performance indicated a bias of 0.3 mm and an imprecision of 0.6 mm. Application bias was 3.8 mm and imprecision was 2.8 mm for aneurysm diameter. The VTMOM did not improve aneurysm clip size selection accuracy. The VTMOM is a potentially accurate tool for use under the operating microscope. However, its performance when measuring anatomical objects is highly dependent on complex visual features of the object surfaces. Copyright 2000 Wiley-Liss, Inc.

  10. Machine-assisted editing of user-generated content

    NASA Astrophysics Data System (ADS)

    Cremer, Markus; Cook, Randall

    2009-02-01

    Over recent years user-generated content has become ubiquitously available and an attractive entertainment source for millions of end-users. Particularly for larger events, where many people use their devices to capture the action, a great number of short video clips are made available through appropriate web services. The objective of this presentation is to describe a way to combine these clips by analyzing them, and automatically reconstruct the time line in which the individual video clips were captured. This will enable people to easily create a compelling multimedia experience by leveraging multiple clips taken by different users from different angles, and across different time spans. The user will be able to shift into the role of a movie director mastering a multi-camera recording of the event. To achieve this goal, the audio portion of the video clips is analyzed, and waveform characteristics are computed with high temporal granularity in order to facilitate precise time alignment and overlap computation of the user-generated clips. Special care has to be given not only to the robustness of the selected audio features against ambient noise and various distortions, but also to the matching algorithm used to align the user-generated clips properly.

  11. Duodenal Ulcer Induced by Hem-o-Lok clip after Reduced Port Laparoscopic Cholecystectomy.

    PubMed

    Soga, Koichi; Kassai, Kyoichi; Itani, Kenji

    2016-03-01

    The patient was a 66-year-old woman who had undergone laparoscopic cholecystectomy (Lap-C) secondary to chronic cholecystitis status post endoscopic choledocholithotomy 13 months previously. During surgery, Hem-o-Lok clips were used to control the cystic duct and the cystic artery. Due to the presence of extensive adhesions of the cystic duct and surrounding tissue, the surgeons had difficulty in debriding the area. Thirteen months after Lap-C, the patient underwent a screening esophagogastroduodenoscopy (EGD), which demonstrated clip appearance at the inferior wall of the first part of the duodenum. In the EGD, duodenal erosions and edema were observed around the clip. We appreciated that endoscopic clip removal would be difficult because of the presence of severe adhesions and inflammation of the duodenal bulb. On clinical examination of the patient, no major abnormalities or physical findings were noted. Therefore, we decided not to attempt to remove the clip. The patient was treated with an oral proton pump inhibitor to prevent extensive duodenal mucosal injury. Two months later, we repeated the EGD, which revealed that the clip was no longer present, and the duodenum was covered with normal mucosa surrounding the scar.

  12. Plastic bread-bag clips in the gastrointestinal tract: report of 5 cases and review of the literature

    PubMed Central

    Newell, K J; Taylor, B; Walton, J C; Tweedie, E J

    2000-01-01

    Plastic bread-bag clips have been identified as a cause of local perforation or obstruction at many sites in the gastrointestinal tract. This study is the largest case series yet reported, consisting of 3 cases presenting as small-bowel perforation, 1 case in which the clip was found incidentally in the small bowel at laparotomy during vascular surgery and 1 case in which the clip was found incidentally in the small bowel at autopsy. In all cases there was no radiographic evidence to suggest a foreign body in the gastrointestinal tract. People older than 60 years of age who have either partial or full dentures seem to be particularly at risk for the accidental ingestion of these devices. If accidentally ingested, plastic bread-bag clips represent a significant health hazard. As the population ages, small-bowel perforation secondary to ingestion of such clips may occur with increasing frequency. The authors recommend elimination or redesign of the clips, to prevent their being swallowed and becoming impacted in the small bowel or to allow them to be identified in the gastrointestinal tract by conventional radiography. PMID:10701390

  13. Age-Related Differences in Judgments of Inappropriate Behavior are Related to Humor Style Preferences

    PubMed Central

    Stanley, Jennifer Tehan; Lohani, Monika; Isaacowitz, Derek M.

    2014-01-01

    Identifying social gaffes is important for maintaining relationships. Older adults are less able than young to discriminate between socially appropriate and inappropriate behavior in video clips. One open question is how these social appropriateness ratings relate to potential age differences in the perception of what is actually funny or not. In the present study, young, middle-aged, and older adults were equally able to discriminate between appropriate and inappropriate social behavior in a diverse set of clips relevant to both age groups. However, young and middle-aged adults rated the gaffe clips as funnier than control clips and young adults smiled more during the inappropriate clips than the control clips. Older adults did not show this pattern, suggesting that they did not find the inappropriate clips funny. Additionally, young adults endorsed a more aggressive humor style than middle-aged and older adults and aggressive humor style endorsement mediated age differences in social appropriateness ratings. Results are discussed in terms of possible mechanisms such as cohort differences in humor and developmental prioritization of certain humor styles, as well as the importance of investigating age differences in both abilities and preferences. PMID:25244473

  14. 21 CFR 868.6225 - Nose clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ANESTHESIOLOGY DEVICES Miscellaneous § 868.6225 Nose clip. (a) Identification. A nose clip is a device intended to close a patient's external nares (nostrils) during diagnostic or therapeutic procedures. (b... from the current good manufacturing practice requirements of the quality system regulation in part 820...

  15. A CLIPS expert system for clinical flow cytometry data analysis

    NASA Technical Reports Server (NTRS)

    Salzman, G. C.; Duque, R. E.; Braylan, R. C.; Stewart, C. C.

    1990-01-01

    An expert system is being developed using CLIPS to assist clinicians in the analysis of multivariate flow cytometry data from cancer patients. Cluster analysis is used to find subpopulations representing various cell types in multiple datasets each consisting of four to five measurements on each of 5000 cells. CLIPS facts are derived from results of the clustering. CLIPS rules are based on the expertise of Drs. Stewart, Duque, and Braylan. The rules incorporate certainty factors based on case histories.

  16. Effects of fin clipping on survival and position-holding behavior of brown darters, Etheostoma edwini

    USGS Publications Warehouse

    Champagne, C.E.; Austin, J.D.; Jelks, H.L.; Jordan, F.

    2008-01-01

    Advent of the polymerase chain reaction (PCR) has allowed conservation biologists to use small portions of tissue to obtain genetic material for population genetic and taxonomic study. Fin clips are used extensively in large-sized fishes, but it is unclear how clipping enough fin tissue for genetic analysis will affect survival of smaller fishes such as minnows and darters, which are among the most threatened organisms in North America. We tested for effects of fin clipping on survival and swimming performance of non-threatened Brown Darters (Etheostoma edwini) in order to justify similar tissue collection in co-occurring endangered Okaloosa Darters (E. okaloosae). We collected 48 E. edwini from a small stream in northwest Florida, transported them to the laboratory, and randomly assigned them to one of three experimental groups: control, entire right pectoral fin removed, or rear half of caudal fin removed. Successful amplification of DNA indicated that our fin clips were large enough for genetic analysis using PCR. No mortality occurred during a two-month observation period. Fin regeneration was almost complete and we could not visually distinguish clipped fins from control fins after two months. We then randomly assigned fish into the same three experimental groups, clipped fins, and evaluated their ability to hold position at 20 cm/sec in an experimental flow chamber. Neither fish size nor treatment type affected position-holding behavior. Fin clipping does not adversely affect survival and swimming performance of E. edwini maintained in the laboratory. Additional research on the effects of fin clipping on small-sized fishes should be conducted in the field to evaluate survival under natural conditions. ?? 2008 by the American Society of Ichthyologists and Herpetologists.

  17. Efficacy of electrocoagulation in sealing the cystic artery and cystic duct occluded with only one absorbable clip during laparoscopic cholecystectomy.

    PubMed

    Yang, Chang-Ping; Cao, Jin-Lin; Yang, Ren-Rong; Guo, Hong-Rong; Li, Zhao-Hui; Guo, Hai-Ying; Shao, Yin-Can; Liu, Gui-Bao

    2014-02-01

    Even though laparoscopic cholecystectomy (LC) emerged over 20 years ago, controversies persist with regard to the best method to ligate the cystic duct and artery. We proposed to assess the effectiveness and safety of electrocoagulation to seal the cystic artery and cystic duct after their occlusion with only one absorbable clip. We retrospectively compared the clinical data for 635 patients undergoing LC using electrocoagulation to seal the cystic artery and cystic duct that were occluded with only one absorbable clip (Group 1) and 728 patients undergoing LC using titanium clips (Group 2). In parallel, 30 rabbits randomized into six groups underwent cholecystectomy. After cystic duct ligation with absorbable or titanium clips, the animals were sacrificed 1, 3, or 6 months later, and intraabdominal adhesions were assessed after celiotomy. The mean operative time was significantly shorter (41.6 versus 58.9 minutes, P<.01) in Group 1 than in Group 2. No cystic duct leaks occurred in any patients from Group 1, compared with seven leaks among the 728 (0.96%) patients from Group 2 (P<.05). The morbidity was significantly higher in Group 2 than in Group 1 (3.43% versus 1.58%). Mean intraoperative blood loss and hospitalization length were not significantly different between the two groups, and no deaths occurred in either group. In animal experiments, adhesion was tighter for absorbable than for titanium clips, but fibrous tissue encapsulation was thinner at the site of titanium clips. Electrocoagulation of the cystic artery and cystic duct that were occluded with only one absorbable clip is safe and effective during LC. This approach is associated with shortened operative times and reduced leakage, compared with the standard method using metal clips.

  18. Aneurysm clip motion during magnetic resonance imaging: in vivo experimental study with metallurgical factor analysis.

    PubMed

    Dujovny, M; Kossovsky, N; Kossowsky, R; Valdivia, R; Suk, J S; Diaz, F G; Berman, S K; Cleary, W

    1985-10-01

    Because of various mechanical, metallurgical, and commercial constraints, aneurysm clips are manufactured from different alloys, including several stainless steel and cobalt alloys. Some of the steels contain volume fractions of the crystal phase known as martensite. Martensitic alloys have body-centered cubic structure, are prone to stress corrosion failure, and are ferromagnetic. Martensitic steel can be displaced like a compass needle when exposed to a magnetic field such as that generated during magnetic resonance imaging (MRI). The force exerted by the magnetic field is proportional to the volume fraction of the magnetic phase. We investigated the martensitic content and magnetic field-induced displacement of 12 common aneurysm clips. Four clips of each of the following types were examined: Sugita, Sundt-Kees Multi-Angle, Heifetz (two types), Vari-Angle McFadden, Yasargil (two types), Scoville, Mayfield, Vari-Angle, Pivot, and Kapp. Phase homogeneity and crystal structure were analyzed by x-ray diffraction using a Phillips x-ray diffractometer. Clip deflection in an Oxford Research Systems MRI spectrometer was measured in our in vivo rat abdominal aortic aneurysm model. Results showed that the volume fraction of the martensitic phase in the various clips correlated with the magnitude of the deflection. Among the clips examined, the Yasargil, Sugita, Heifetz Elgiloy, and Vari-Angle McFadden had a nonmartensitic composition and did not deflect in the magnetic field. The Scoville contained 5% martensite and deflected only marginally. Martensite comprised 35% of the Mayfield clip, which deflected 45 degrees, and 90% of the Heifetz, Vari-Angle, Pivot, and Sundt-Kees Multi-Angle clips, which deflected approximately 70 degrees or slipped off the aneurysm.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Intelligent tutoring using HyperCLIPS

    NASA Technical Reports Server (NTRS)

    Hill, Randall W., Jr.; Pickering, Brad

    1990-01-01

    HyperCard is a popular hypertext-like system used for building user interfaces to databases and other applications, and CLIPS is a highly portable government-owned expert system shell. We developed HyperCLIPS in order to fill a gap in the U.S. Army's computer-based instruction tool set; it was conceived as a development environment for building adaptive practical exercises for subject-matter problem-solving, though it is not limited to this approach to tutoring. Once HyperCLIPS was developed, we set out to implement a practical exercise prototype using HyperCLIPS in order to demonstrate the following concepts: learning can be facilitated by doing; student performance evaluation can be done in real-time; and the problems in a practical exercise can be adapted to the individual student's knowledge.

  20. Stone formation from nonabsorbable clip migration into the collecting system after robot-assisted partial nephrectomy.

    PubMed

    Lee, Ziho; Reilly, Christopher E; Moore, Blake W; Mydlo, Jack H; Lee, David I; Eun, Daniel D

    2014-01-01

    We describe a case in which a Weck Hem-o-lok clip (Teleflex, Research Triangle Park, USA) migrated into the collecting system and acted as a nidus for stone formation in a patient after robot-assisted partial nephrectomy. The patient presented 2 years postoperatively with left-sided renal colic. Abdominal computed tomography scan showed a 10 millimeter renal calculus in the left middle pole. After using laser lithotripsy to fragment the overlying renal stone, a Weck Hem-o-lok clip was found to be embedded in the collecting system. A laser fiber through a flexible ureteroscope was used to successfully dislodge the clip from the renal parenchyma, and a stone basket was used to extract the clip.

  1. 40 CFR 60.3078 - What definitions must I know?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... shavings. Wood waste does not include: (1) Grass, grass clippings, bushes, shrubs, and clippings from bushes and shrubs from residential, commercial/retail, institutional, or industrial sources as part of..., flake board, and oriented strand board). Yard waste means grass, grass clippings, bushes, shrubs, and...

  2. 40 CFR 60.2977 - What definitions must I know?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... shavings. Wood waste does not include: (1) Grass, grass clippings, bushes, shrubs, and clippings from bushes and shrubs from residential, commercial/retail, institutional, or industrial sources as part of..., flake board, and oriented strand board). Yard waste means grass, grass clippings, bushes, shrubs, and...

  3. 21 CFR 886.3100 - Ophthalmic tantalum clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... blood vessels in the eye. (b) Classification. Class II (special controls). The device is exempt from the...) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3100 Ophthalmic tantalum clip. (a) Identification. An ophthalmic tantalum clip is a malleable metallic device intended to be implanted permanently...

  4. A graphical interface to CLIPS using SunView

    NASA Technical Reports Server (NTRS)

    Feagin, Terry

    1990-01-01

    The importance of the incorporation of various graphics-oriented features into CLIPS is discussed. These popular features, which have been implemented in a version of CLIPS developed for a popular workstation, are described and their usefulness in the development of expert systems is examined.

  5. PubMed Central

    Bédard, S; Desrochers, A; Fecteau, G; Higgins, R

    2001-01-01

    This study was designed to evaluate 4 preoperative skin preparations, that is, more specifically, to compare the efficacy of chlorhexidine gluconate (CG) and povidone-iodine (PI), as well as 2 hair removal techniques (clipper alone or clipper followed by razor) for preoperative skin preparation in cattle. The 4 protocols resulted in a significant decrease in the number of bacterial colony-forming units (cfu). Group 4 (clipping + shaving + CG) had a significantly lower number of preoperative cfu per gel plate compared with groups 1 (clipping + PI) and 3 (clipping + shaving + PI). Skin reaction frequency was significantly higher in groups 3 and 4 (47.8% for both protocols) than in groups 1 and 2 (clipping + PI or CG) (8.7% for both). Wound infection frequency was 4.3% (4/92) and no significant difference was observed between the 4 treatment groups. The 4 protocols tested were equivalent as to efficacy and satisfactorily decreased skin microflora. Clipping alone was shown to be preferable to clipping plus shaving as a method of hair removal in cattle, with fewer skin reactions and no more wound infections. PMID:11265188

  6. Ruptured blebs and racing hearts: autonomic cardiac changes in neurosurgeons during microsurgical clipping of aneurysms.

    PubMed

    Ganne, Chaitanya; Talkad, Sathyaprabha N; Srinivas, Dwarakanath; Somanna, Sampath

    2016-08-01

    In this study, we intend to evaluate the autonomic changes occurring in neurosurgeons and thus the stress during microsurgical clipping of aneurysms. The aim of the current study is to evaluate the heart rate variability (HRV) of the neurosurgeons during microsurgical clipping of aneurysm by using continuous real time monitoring of the ECG intraoperatively. Lead II ECG was recorded using Bioharness(®) (Zephyr Technologies, Annapolis, MD) in 4 healthy neurosurgeons who performed 29 microsurgical clipping of aneurysms. ECG from 21 surgeries was analysed (LabChart(®) software, ADInstruments, Dunedin, New Zealand) across five stages: Baseline (BL), sylvian fissure dissection (SFD), perianeurysmal dissection (PAD), clipping of the aneurysm (CLIP) and haemostasis (HEMO). There was a reduction in TP and an increased LF/HF ratio in spite of suppression of both LF and HF powers. Contrary to the common understanding that the sympathetic limb of the autonomic system mostly mediates responses during stress and anxiety, we found that there was a significant contribution of the parasympathetic system too.

  7. From tricuspid to double orifice Morphology: Percutaneous tricuspid regurgitation repair with the MitraClip device in congenitally corrected-transposition of great arteries.

    PubMed

    Picard, Fabien; Tadros, Victor-Xavier; Asgar, Anita W

    2017-09-01

    Edge to edge transcatheter mitral valve repair with MitraClip (Abbott Vascular, Menlo Park, CA) is increasing for high-risk surgical patients with significant mitral regurgitation. Patients with congenitally corrected transposition of the great arteries (CCTGA) presenting with tricuspid valve regurgitation of a systemic right ventricle may represent particularly challenging candidates for MitraClip given their anatomy. We report the case of a 67-year-old gentleman with CCTGA and severe tricuspid regurgitation who was referred for MitraClip implantation after heart team consensus. Successful implantation of one clip was performed, achieving a significant reduction of the regurgitation. Similarly, favorable findings were confirmed at 6 months, 1 and 2 years follow-up and the patient had no recurrent heart failure admissions after 2-year follow-up. We describe the technical considerations and the importance of 3D-transoesophageal echocardiography for performing the MitraClip of a trileaflet systemic atrioventricular valve. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  8. HYPERCLIPS

    NASA Technical Reports Server (NTRS)

    Hill, R. W.

    1994-01-01

    The integration of CLIPS into HyperCard combines the intuitive, interactive user interface of the Macintosh with the powerful symbolic computation of an expert system interpreter. HyperCard is an excellent environment for quickly developing the front end of an application with buttons, dialogs, and pictures, while the CLIPS interpreter provides a powerful inference engine for complex problem solving and analysis. In order to understand the benefit of integrating HyperCard and CLIPS, consider the following: HyperCard is an information storage and retrieval system which exploits the use of the graphics and user interface capabilities of the Apple Macintosh computer. The user can easily define buttons, dialog boxes, information templates, pictures, and graphic displays through the use of the HyperCard tools and scripting language. What is generally lacking in this environment is a powerful reasoning engine for complex problem solving, and this is where CLIPS plays a role. CLIPS 5.0 (C Language Integrated Production System, v5.0) was developed at the Johnson Space Center Software Technology Branch to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 5.0 supports forward chaining rule systems, object-oriented language, and procedural programming for the construction of expert systems. It features incremental reset, seven conflict resolution stategies, truth maintenance, and user-defined external functions. Since CLIPS is implemented in the C language it is highly portable; in addition, it is embeddable as a callable routine from a program written in another language such as Ada or Fortran. By integrating HyperCard and CLIPS the advantages and uses of both packages are made available for a wide range of applications: rapid prototyping of knowledge-based expert systems, interactive simulations of physical systems and intelligent control of hypertext processes, to name a few. HyperCLIPS 2.0 is written in C-Language (54%) and Pascal (46%) for Apple Macintosh computers running Macintosh System 6.0.2 or greater. HyperCLIPS requires HyperCard 1.2 or higher and at least 2Mb of RAM are recommended to run. An executable is provided. To compile the source code, the Macintosh Programmer's Workshop (MPW) version 3.0, CLIPS 5.0 (MSC-21927), and the MPW C-Language compiler are also required. NOTE: Installing this program under Macintosh System 7 requires HyperCard v2.1. This program is distributed on a 3.5 inch Macintosh format diskette. A copy of the program documentation is included on the diskette, but may be purchased separately. HyperCLIPS was developed in 1990 and version 2.0 was released in 1991. HyperCLIPS is a copyrighted work with all copyright vested in NASA. Apple, Macintosh, MPW, and HyperCard are registered trademarks of Apple Computer, Inc.

  9. Neural network versus classical time series forecasting models

    NASA Astrophysics Data System (ADS)

    Nor, Maria Elena; Safuan, Hamizah Mohd; Shab, Noorzehan Fazahiyah Md; Asrul, Mohd; Abdullah, Affendi; Mohamad, Nurul Asmaa Izzati; Lee, Muhammad Hisyam

    2017-05-01

    Artificial neural network (ANN) has advantage in time series forecasting as it has potential to solve complex forecasting problems. This is because ANN is data driven approach which able to be trained to map past values of a time series. In this study the forecast performance between neural network and classical time series forecasting method namely seasonal autoregressive integrated moving average models was being compared by utilizing gold price data. Moreover, the effect of different data preprocessing on the forecast performance of neural network being examined. The forecast accuracy was evaluated using mean absolute deviation, root mean square error and mean absolute percentage error. It was found that ANN produced the most accurate forecast when Box-Cox transformation was used as data preprocessing.

  10. Measurement Of The Deformation Of Rail Track Fastening Clips By Holographic Interferometry

    NASA Astrophysics Data System (ADS)

    Ennos, A. E.

    1985-01-01

    One method of attaching railway rails to the sleepers (ties) is to use spring steel clips, mounted on either side of the rail, that exert a downward force on the foot of the rail. In service these will flex with the passing of a train. Holographic interferometry has been used to measure quantitatively the manner in which the spring clips deform when the rail is given a displacement in a prescribed direction. The information can be used both to provide data on the bending and torsion of the clip, and as a means of testing the validity of finite element analysis calculations. Measurements on three different designs of commercial clip were carried out on a section of sleeper holding a short length of rail. A controlled upward displacement of the rail was achieved pneumatically by means of plastic pipes interposed between rail and concrete sleeper. Double exposure holograms were recorded on large photographic plates, allowing views of the fringe patterns from widely spaced directions. The three components of displacement at points along the length of the clip were calculated from fringe information taken from nine directions, using least squares fit to obtain increased accuracy. Rotations of the surface were calculated from the fringe directions and spacings. In addition to deformation measurements of the clip under service conditions, information on local yielding of the clip under increasing stress was also obtained by means of real-time interferometry, using an instant hologram camera.

  11. Accuracy assessment methods of tissue marker clip placement after 11-gauge vacuum-assisted stereotactic breast biopsy: comparison of measurements using direct and conventional methods.

    PubMed

    Yatake, Hidetoshi; Sawai, Yuka; Nishi, Toshio; Nakano, Yoshiaki; Nishimae, Ayaka; Katsuda, Toshizo; Yabunaka, Koichi; Takeda, Yoshihiro; Inaji, Hideo

    2017-07-01

    The objective of the study was to compare direct measurement with a conventional method for evaluation of clip placement in stereotactic vacuum-assisted breast biopsy (ST-VAB) and to evaluate the accuracy of clip placement using the direct method. Accuracy of clip placement was assessed by measuring the distance from a residual calcification of a targeted calcification clustered to a clip on a mammogram after ST-VAB. Distances in the craniocaudal (CC) and mediolateral oblique (MLO) views were measured in 28 subjects with mammograms recorded twice or more after ST-VAB. The difference in the distance between the first and second measurements was defined as the reproducibility and was compared with that from a conventional method using a mask system with overlap of transparent film on the mammogram. The 3D clip-to-calcification distance was measured using the direct method in 71 subjects. The reproducibility of the direct method was higher than that of the conventional method in CC and MLO views (P = 0.002, P < 0.001). The median 3D clip-to-calcification distance was 2.8 mm, with an interquartile range of 2.0-4.8 mm and a range of 1.1-36.3 mm. The direct method used in this study was more accurate than the conventional method, and gave a median 3D distance of 2.8 mm between the calcification and clip.

  12. Spatially controlled coating of continuous liquid Interface production microneedles for transdermal protein delivery.

    PubMed

    Caudill, Cassie L; Perry, Jillian L; Tian, Shaomin; Luft, J Christopher; DeSimone, Joseph M

    2018-06-09

    Microneedle patches, arrays of micron-scale projections that penetrate skin in a minimally invasive manner, are a promising tool for transdermally delivering therapeutic proteins. However, current microneedle fabrication techniques are limited in their ability to fabricate microneedles rapidly and with a high degree of control over microneedle design parameters. We have previously demonstrated the ability to fabricate microneedle patches with a range of compositions and geometries using the novel additive manufacturing technique Continuous Liquid Interface Production (CLIP). Here, we establish a method for dip coating CLIP microneedles with protein cargo in a spatially controlled manner. Microneedle coating mask devices were fabricated with CLIP and utilized to coat polyethylene glycol-based CLIP microneedles with model proteins bovine serum albumin, ovalbumin, and lysozyme. The design of the coating mask device was used to control spatial deposition and loading of coated protein cargo on the microneedles. CLIP microneedles rapidly released coated protein cargo both in solution and upon insertion into porcine skin. The model enzyme lysozyme was shown to retain its activity throughout the CLIP microneedle coating process, and permeation of bovine serum albumin across full thickness porcine skin was observed after application with coated CLIP microneedles. Protein-coated CLIP microneedles were applied to live mice and showed sustained retention of protein cargo in the skin over 72 h. These results demonstrate the utility of a versatile coating platform for preparation of precisely coated microneedles for transdermal therapeutic delivery. Copyright © 2018. Published by Elsevier B.V.

  13. Impulsivity Moderates the Effects of Movie Alcohol Portrayals on Adolescents’ Willingness to Drink

    PubMed Central

    Gibbons, Frederick X.; Kingsbury, John H.; Wills, Thomas A.; Finneran, Stephanie D.; Cin, Sonya Dal; Gerrard, Meg

    2016-01-01

    This study examined impulsivity as a moderator of adolescents’ reactions to positive vs. negative portrayals of drinking in American movie clips. Impulsivity, along with willingness and intentions to drink in the future, were assessed in a pretest session. In the experimental sessions, adolescents viewed a series of clips that showed drinking associated with either positive outcomes (e.g., social facilitation) or negative outcomes (fights, arguments). A third group viewed clips with similar positive or negative outcomes, but no alcohol consumption. All participants then responded to an implicit measure of attentional bias regarding alcohol (a dot probe), followed by explicit alcohol measures (self-reports of willingness and intentions to drink). Hypotheses, based on dual-processing theories, were: a) high-impulsive adolescents would respond more favorably than low-impulsive adolescents to the positive clips, but not the negative clips; and b) this difference in reactions to the positive clips would be larger on the willingness than the intention measures. Results supported the hypotheses: Adolescents high in impulsivity reported the highest willingness to drink in the positive-clip condition, but were slightly less willing than others in the negative-clip condition. In addition, results on the dot probe task indicated that reaction times to alcohol words were negatively correlated with changes in alcohol willingness, but not intention; i.e., the faster their response to the alcohol words, the more their willingness increased. The results highlight the utility of a dual-processing perspective on media influence. PMID:27099959

  14. Digital video clips for improved pedagogy and illustration of scientific research — with illustrative video clips on atomic spectrometry

    NASA Astrophysics Data System (ADS)

    Michel, Robert G.; Cavallari, Jennifer M.; Znamenskaia, Elena; Yang, Karl X.; Sun, Tao; Bent, Gary

    1999-12-01

    This article is an electronic publication in Spectrochimica Acta Electronica (SAE), a section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by an electronic archive, stored on the CD-ROM accompanying this issue. The archive contains video clips. The main article discusses the scientific aspects of the subject and explains the purpose of the video files. Short, 15-30 s, digital video clips are easily controllable at the computer keyboard, which gives a speaker the ability to show fine details through the use of slow motion. Also, they are easily accessed from the computer hard drive for rapid extemporaneous presentation. In addition, they are easily transferred to the Internet for dissemination. From a pedagogical point of view, the act of making a video clip by a student allows for development of powers of observation, while the availability of the technology to make digital video clips gives a teacher the flexibility to demonstrate scientific concepts that would otherwise have to be done as 'live' demonstrations, with all the likely attendant misadventures. Our experience with digital video clips has been through their use in computer-based presentations by undergraduate and graduate students in analytical chemistry classes, and by high school and middle school teachers and their students in a variety of science and non-science classes. In physics teaching laboratories, we have used the hardware to capture digital video clips of dynamic processes, such as projectiles and pendulums, for later mathematical analysis.

  15. Angiographic and epidemiological characteristics associated with aneurysm remnants after microsurgical clipping

    PubMed Central

    Dellaretti, Marcos; da Silva Martins, Warley Carvalho; Dourado, Jules Carlos; Faglioni, Wilson; Quadros, Ricardo Souza; de Souza Moraes, Vítor Vieira; de Souza Filho, Carlos Batista Alves

    2017-01-01

    Background: Despite new techniques for the treatment of cerebral aneurysms, the percentage of aneurysm remnants after surgical intervention seems to be relatively constant. The objective of this study was to assess angiographic and epidemiological features associated with aneurysm remnants after microsurgical clipping. Methods: This study was conducted from February 2009 to August 2012 on a series of 90 patients with 105 aneurysms referred to the Santa Casa of Belo Horizonte who were surgically treated and angiographically controlled. Results: Surgical clipping was considered incomplete in 13.3% of the aneurysms. The mean age of cases with an aneurysm remnant was 57.5 years, whereas the mean age without aneurysm remnant was 49.7 years (P = 0.02). Aneurysm remnants were detected more frequently on the internal carotid artery, nevertheless, no statistically significant differences were verified when comparing the locations. Aneurysm size in the preoperative angiography verified that the mean size of aneurysms operated was 6.56 mm, such that in cases showing a postoperative remnant, the mean size was 9.7 mm and in cases with complete clipping it was 6.08 mm (P = 0.02). Postoperative angiography showed that, in cases with residual aneurysm, the number of clips used was higher – a mean of 1.8 for complete clipping and 3.1 for incomplete clipping (P < 0.001). Conclusions: Aneurysm size and patient age showed significant correlations with residual intracranial aneurysm. The mean number of clips used was higher in cases with incomplete occlusion. PMID:28904825

  16. Regional comparison of absolute gravimeters SIM.M.G-K1 key comparison

    NASA Astrophysics Data System (ADS)

    Newell, D. B.; van Westrum, D.; Francis, O.; Kanney, J.; Liard, J.; Ramirez, A. E.; Lucero, B.; Ellis, B.; Greco, F.; Pistorio, A.; Reudink, R.; Iacovone, D.; Baccaro, F.; Silliker, J.; Wheeler, R. D.; Falk, R.; Ruelke, A.

    2017-01-01

    Twelve absolute gravimeters were compared during the regional Key Comparison SIM.M.G-K1 of absolute gravimeters. The four gravimeters were from different NMIs and DIs. The comparison was linked to the CCM.G-K2 through EURAMET.M.G-K2 via the DI gravimeter FG5X-216. Overall, the results and uncertainties indicate an excellent agreement among the gravimeters, with a standard deviation of the gravimeters' DoEs better than 1.3 μGal. In the case of the official solution, all the gravimeters are in equivalence well within the declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Absolute distance measurement with correction of air refractive index by using two-color dispersive interferometry.

    PubMed

    Wu, Hanzhong; Zhang, Fumin; Liu, Tingyang; Li, Jianshuang; Qu, Xinghua

    2016-10-17

    Two-color interferometry is powerful for the correction of the air refractive index especially in the turbulent air over long distance, since the empirical equations could introduce considerable measurement uncertainty if the environmental parameters cannot be measured with sufficient precision. In this paper, we demonstrate a method for absolute distance measurement with high-accuracy correction of air refractive index using two-color dispersive interferometry. The distances corresponding to the two wavelengths can be measured via the spectrograms captured by a CCD camera pair in real time. In the long-term experiment of the correction of air refractive index, the experimental results show a standard deviation of 3.3 × 10-8 for 12-h continuous measurement without the precise knowledge of the environmental conditions, while the variation of the air refractive index is about 2 × 10-6. In the case of absolute distance measurement, the comparison with the fringe counting interferometer shows an agreement within 2.5 μm in 12 m range.

  18. 3D shape measurements with a single interferometric sensor for in-situ lathe monitoring

    NASA Astrophysics Data System (ADS)

    Kuschmierz, R.; Huang, Y.; Czarske, J.; Metschke, S.; Löffler, F.; Fischer, A.

    2015-05-01

    Temperature drifts, tool deterioration, unknown vibrations as well as spindle play are major effects which decrease the achievable precision of computerized numerically controlled (CNC) lathes and lead to shape deviations between the processed work pieces. Since currently no measurement system exist for fast, precise and in-situ 3d shape monitoring with keyhole access, much effort has to be made to simulate and compensate these effects. Therefore we introduce an optical interferometric sensor for absolute 3d shape measurements, which was integrated into a working lathe. According to the spindle rotational speed, a measurement rate of 2,500 Hz was achieved. In-situ absolute shape, surface profile and vibration measurements are presented. While thermal drifts of the sensor led to errors of several mµm for the absolute shape, reference measurements with a coordinate machine show, that the surface profile could be measured with an uncertainty below one micron. Additionally, the spindle play of 0.8 µm was measured with the sensor.

  19. Impact of Oncoming Headlight Glare With Cataracts: A Pilot Study

    PubMed Central

    Hwang, Alex D.; Tuccar-Burak, Merve; Goldstein, Robert; Peli, Eli

    2018-01-01

    Purpose: Oncoming headlight glare (HLG) reduces the visibility of objects on the road and may affect the safety of nighttime driving. With cataracts, the impact of oncoming HLG is expected to be more severe. We used our custom HLG simulator in a driving simulator to measure the impact of HLG on pedestrian detection by normal vision subjects with simulated mild cataracts and by patients with real cataracts. Methods: Five normal vision subjects drove nighttime scenarios under two HLG conditions (with and without HLG: HLGY and HLGN, respectively), and three vision conditions (with plano lens, simulated mild cataract, and optically blurred clip-on). Mild cataract was simulated by applying a 0.8 Bangerter diffusion foil to clip-on plano lenses. The visual acuity with the optically blurred lenses was individually chosen to match the visual acuity with the simulated cataract clip-ons under HLGN. Each nighttime driving scenario contains 24 pedestrian encounters, encompassing four pedestrian types; walking along the left side of the road, walking along the right side of the road, crossing the road from left to right, and crossing the road from right to left. Pedestrian detection performances of five patients with mild real cataracts were measured using the same setup. The cataract patients were tested only in HLGY and HLGN conditions. Participants’ visual acuity and contrast sensitivity were also measured in the simulator with and without stationary HLG. Results: For normal vision subjects, both the presence of oncoming HLG and wearing the simulated cataract clip-on reduced pedestrian detection performance. The subjects performed worst in events where the pedestrian crossed from the left, followed by events where the pedestrian crossed from the right. Significant interactions between HLG condition and other factors were also found: (1) the impact of oncoming HLG with the simulated cataract clip-on was larger than with the plano lens clip-on, (2) the impact of oncoming HLG was larger with the optically blurred clip-on than with the plano lens clip-on, but smaller than with the simulated cataract clip-on, and (3) the impact was larger for the pedestrians that crossed from the left than those that crossed from the right, and for the pedestrians walking along the left side of the road than walking along the right side of the road, suggesting that the pedestrian proximity to the glare source contributed to the performance reduction. Under HLGN, almost no pedestrians were missed with the plano lens or the simulated cataract clip-on (0 and 0.5%, respectively), but under HLGY, the rate of pedestrian misses increased to 0.5 and 6%, respectively. With the optically blurred clip-on, the percent of missed pedestrians under HLGN and HLGY did not change much (5% and 6%, respectively). Untimely response rate increased under HLGY with the plano lens and simulated cataract clip-ons, but the increase with the simulated cataract clip-on was significantly larger than with the plano lens clip-on. The contrast sensitivity with the simulated cataract clip-on was significantly degraded under HLGY. The visual acuity with the plano lens clip-on was significantly improved under HLGY, possibly due to pupil myosis. The impact of HLG measured for real cataract patients was similar to the impact on performance of normal vision subjects with simulated cataract clip-ons. Conclusion: Even with mild (simulated or real) cataracts, a substantial negative effect of oncoming HLG was measurable in the detection of crossing and walking-along pedestrians. The lowered pedestrian detection rates and longer response times with HLGY demonstrate a possible risk that oncoming HLG poses to patients driving with cataracts. PMID:29559933

  20. Rectangularization of the survival curve in The Netherlands, 1950-1992.

    PubMed

    Nusselder, W J; Mackenbach, J P

    1996-12-01

    In this article we determine whether rectangularization of the survival curve occurred in the Netherlands in the period 1950-1992. Rectangularization is defined as a trend toward a more rectangular shape of the survival curve due to increased survival and concentration of deaths around the mean age at death. We distinguish between absolute and relative rectangularization, depending on whether an increase in life expectancy is accompanied by concentration of deaths into a smaller age interval or into a smaller proportion of total life expectancy. We used measures of variability based on Keyfitz' H and the standard deviation, both life table-based. Our results show that absolute and relative rectangularization of the entire survival curve occurred in both sexes and over the complete period (except for the years 1955-1959 and 1965-1969 in men). At older ages, results differ between sexes, periods, and an absolute versus a relative definition of rectangularization. Above age 60 1/2, relative rectangularization occurred in women over the complete period and in men since 1975-1979 only, whereas absolute rectangularization occurred in both sexes since the period of 1980-1984. The implications of the recent rectangularization at older ages for achieving compression of morbidity are discussed.

  1. 21 CFR 882.4200 - Clip removal instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip removal instrument. 882.4200 Section 882.4200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4200 Clip removal instrument. (a...

  2. 21 CFR 882.4175 - Aneurysm clip applier.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a...

  3. 21 CFR 882.5225 - Implanted malleable clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implanted malleable clip. 882.5225 Section 882.5225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5225 Implanted malleable clip...

  4. 21 CFR 882.4190 - Clip forming/cutting instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip forming/cutting instrument. 882.4190 Section 882.4190 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4190 Clip forming...

  5. 21 CFR 882.5225 - Implanted malleable clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Implanted malleable clip. 882.5225 Section 882.5225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5225 Implanted malleable clip...

  6. 21 CFR 882.4175 - Aneurysm clip applier.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a...

  7. 21 CFR 882.5200 - Aneurysm clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm...

  8. 21 CFR 882.5200 - Aneurysm clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm...

  9. 21 CFR 882.4200 - Clip removal instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip removal instrument. 882.4200 Section 882.4200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4200 Clip removal instrument. (a...

  10. 21 CFR 870.3250 - Vascular clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vascular clip. 870.3250 Section 870.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3250 Vascular clip. (a) Identification. A vascular...

  11. 21 CFR 870.3250 - Vascular clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vascular clip. 870.3250 Section 870.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3250 Vascular clip. (a) Identification. A vascular...

  12. Implementing a frame representation in CLIPS/COOL

    NASA Technical Reports Server (NTRS)

    Myers, Leonard; Snyder, James

    1991-01-01

    An implementation is described and evaluated of frames in COOL. The test case is a frame based semantic network previously implemented in CLIPS (C Language Integrated Production System) Version 4.3 as part of the Intelligent Computer Aided Design System (ICADS) and reported at the first CLIPS conference.

  13. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  14. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  15. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  16. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  17. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  18. Can We Use the Disposable Laparoscopic Clip Appliers as Suture Anchors? An In Vitro Feasibility Study.

    PubMed

    Buchholz, Vered; Sadot, Eran; Spivak, Hadar

    2015-08-01

    Intracorporeal suturing is time-consuming and could be difficult in certain operative circumstances. Instead of knot tying, specially designed clips have been introduced to anchor and secure the end of a single strand or suture. Although these clips provide a maximal required holding grip (HG), they considerably increase the cost of the procedure. The aim of this in vitro study was to identify the feasibility, and means of achieving the best HG, of commonly used disposable automatic clip appliers (LCAs) over regular strands. We placed 2-0 PDS (rigid) and 2-0 Vicryl (soft) sutures through fresh gastric wall specimens. Six different commercial-type LCAs, all having large or medium/large clips, were applied at the distal end of each suture. An IMDA manual digital force gauge was used to measure the HG of each clip at 2 positions: the middle clip position and the angle (at the crouch) position. A total of 192 measurements were taken. The results were classified into 3 HG levels measured by Newton units (N): the strongest grip (> 1 N), medium grip (> 0.5 and < 1 N), and weak grip (< 0.5 N). The strongest HG was obtained by applying 10 to 12 mm LCAs with large or medium/large clips over PDS at an angle position (HG = 1.1 ± 0.2 to 1.6 ± 0.3 N). The weakest grip was obtained by applying any type of LCA over Vicryl at the middle position (HG = 0.08 ± 0.04 to 0.2 ± 0.06 N, P < 0.001). The latter was associated with clips freely falling off the sutures even before applying any force. In general, more force was needed to dislodge any brand clip from the PDS compared with Vicryl suture (0.8 ± 0.6 vs. 0.4 ± 0.3 N, P < 0.001). The angle position was always stronger than the middle position (0.9 ± 0.6 vs. 0.3 ± 0.2 N, P < 0.001). There was a trend for the 10 to 12 mm LCA to have a better HG than the 5 mm ones (0.65 ± 0.5 vs. 0.51 ± 0.5 N, P = 0.08). We propose that 10 to 12 mm LCAs generate enough HG to secure a single strand when clips are placed at the angle position. This is especially true over PDS (hard) strands. The application of 5 mm LCA clips to secure the end of the Vicryl strand is not recommended. Further clinical studies are warranted.

  19. Chinese Language Video Clips. [CD-ROM].

    ERIC Educational Resources Information Center

    Fleming, Stephen; Hipley, David; Ning, Cynthia

    This compact disc includes video clips covering six topics for the learner of Chinese: personal information, commercial transactions, travel and leisure, health and sports, food and school. Filmed on location in Beijing, these naturalistic video clips consist mainly of unrehearsed interviews of ordinary people. The learner is lead through a series…

  20. 21 CFR 870.3260 - Vena cava clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...

  1. A Simple Recipe for Whitening Old Newspaper Clippings.

    ERIC Educational Resources Information Center

    Carter, Henry A.

    1995-01-01

    Describes a method for experimenting with both whitening and deacidifying old newspaper clippings using sodium borohydride bleaching. Clippings are soaked in distilled water then immersed in sodium borohydride for 15-20 minutes. After rinsing with distilled water, the paper is washed with saturated Ca(OH)2 solution. Readers should not begin…

  2. Understanding and Applying Psychology through Use of News Clippings.

    ERIC Educational Resources Information Center

    Rider, Elizabeth A.

    1992-01-01

    Discusses a student project for psychology courses in which students collect newspaper clippings that illustrate psychological concepts. Explains that the students record the source and write a brief description of the clipping, explaining how it relates to a psychological concept or theory. Includes results of student evaluations of the…

  3. 21 CFR 882.4190 - Clip forming/cutting instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip forming/cutting instrument. 882.4190 Section 882.4190 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES.../cutting instrument. (a) Identification. A clip forming/cutting instrument is a device used by the...

  4. 21 CFR 870.3260 - Vena cava clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...

  5. Task acceptability and workload of driving city streets, rural roads, and expressways : ratings from video clips.

    DOT National Transportation Integrated Search

    2007-05-01

    Subjects rated the workload of clips of forward road scenes (from the advanced collision avoidance system (ACAS) field operational test) in relation to 2 anchor clips of Level of Service (LOS) A and E (light and heavy traffic), and indicated if they ...

  6. 21 CFR 878.4320 - Removable skin clip.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...

  7. 21 CFR 878.4320 - Removable skin clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...

  8. 21 CFR 878.4320 - Removable skin clip.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...

  9. 21 CFR 878.4320 - Removable skin clip.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...

  10. Constructing complex graphics applications with CLIPS and the X window system

    NASA Technical Reports Server (NTRS)

    Faul, Ben M.

    1990-01-01

    This article will demonstrate how the artificial intelligence concepts in CLIPS used to solve problems encountered in the design and implementation of graphics applications within the UNIX-X Window System environment. The design of an extended version of CLIPS, called XCLIPS, is presented to show how the X Windows System graphics can be incorporated without losing DOS compatibility. Using XCLIPS, a sample scientific application is built that applies solving capabilities of both two and three dimensional graphics presentations in conjunction with the standard CLIPS features.

  11. Attaching solar collectors to a structural framework utilizing a flexible clip

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruse, John S

    Methods and apparatuses described herein provide for the attachment of solar collectors to a structural framework in a solar array assembly. A flexible clip is attached to either end of each solar collector and utilized to attach the solar collector to the structural framework. The solar collectors are positioned to allow a member of the framework to engage a pair of flexible clips attached to adjacent solar collectors during assembly of the solar array. Each flexible clip may have multiple frame-engaging portions, each with a flange on one end to cause the flexible clip to deflect inward when engaged bymore » the framework member during assembly and to guide each of the frame-engaging portions into contact with a surface of the framework member for attachment.« less

  12. The Use of Film Clips in a Viewing Time Task of Sexual Interests.

    PubMed

    Lalumière, Martin L; Babchishin, Kelly M; Ebsworth, Megan

    2018-04-01

    Viewing time tasks using still pictures to assess age and gender sexual interests have been well validated and are commonly used. The use of film clips in a viewing time task would open up interesting possibilities for the study of sexual interest toward sexual targets or activities that are not easily captured in still pictures. We examined the validity of a viewing time task using film clips to assess sexual interest toward male and female targets, in a sample of 52 young adults. Film clips produced longer viewing times than still pictures. For both men and women, the indices derived from the film viewing time task were able to distinguish individuals who identified as homosexual (14 men, 8 women) from those who identified as heterosexual (15 men, 15 women), and provided comparable group differentiation as indices derived from a viewing time task using still pictures. Men's viewing times were more gender-specific than those of women. Viewing times to film clips were correlated with participants' ratings of sexual appeal of the same clips, and with viewing times to pictures. The results support the feasibility of a viewing time measure of sexual interest that utilizes film clips and, thus, expand the types of sexual interests that could be investigated (e.g., sadism, biastophilia).

  13. [Effects of clipping on nitrogen allocation strategy and compensatory growth of Leymus chinensis under saline-alkali conditions].

    PubMed

    Zheng, Cong Cong; Wang, Yong Jing; Sun, Hao; Wang, Xin Yu; Gao, Ying Zhi

    2017-07-18

    Soil salinization and overgrazing are two main factors limiting animal husbandry in the Songnen Grassland. Leymus chinensis is a dominant rhizome grass, resistant to grazing as well as to-lerant to salt stress. Foliar labeled with 15 N-urea was used to study the nitrogen allocation strategy and compensatory growth response to clipping under saline-alkali conditions. The results showed that the total absorbed 15 N allocated to the aboveground part was more than 60%. Compared with the control treatment (no saline-alkali, no clipping), saline-alkali increased the distribution of 15 N by 5.1% in root; the 15 N distribution into aboveground in the moderate clipping and saline-alkali treatment was 11.6% higher than that of the control, exhibiting over-compensatory growth of aboveground biomass and total biomass, however, 15 N allocated to stem base was significantly increased by 9.5% under severe clipping level and saline-alkali addition, showing under-compensatory growth of shoot, root and total biomass. These results suggested that L. chinensis adapted to mode-rate clipping by over-compensatory growth under salt-alkali stress condition. However, L. chinensis would take a relatively conservative growth strategy through the enhanced N allocation to stem base for storage under severe saline-alkali and clipping conditions.

  14. Acquisition and processing pitfall with clipped traces in surface-wave analysis

    NASA Astrophysics Data System (ADS)

    Gao, Lingli; Pan, Yudi

    2016-02-01

    Multichannel analysis of surface waves (MASW) is widely used in estimating near-surface shear (S)-wave velocity. In the MASW method, generating a reliable dispersion image in the frequency-velocity (f-v) domain is an important processing step. A locus along peaks of dispersion energy at different frequencies allows the dispersion curves to be constructed for inversion. When the offsets are short, the output seismic data may exceed the dynamic ranges of geophones/seismograph, as a result of which, peaks and (or) troughs of traces will be squared off in recorded shot gathers. Dispersion images generated by the raw shot gathers with clipped traces would be contaminated by artifacts, which might be misidentified as Rayleigh-wave phase velocities or body-wave velocities and potentially lead to incorrect results. We performed some synthetic models containing clipped traces, and analyzed amplitude spectra of unclipped and clipped waves. The results indicate that artifacts in the dispersion image are dependent on the level of clipping. A real-world example also shows how clipped traces would affect the dispersion image. All the results suggest that clipped traces should be removed from the shot gathers before generating dispersion images, in order to pick accurate phase velocities and set reasonable initial inversion models.

  15. Assessment of a simple, novel endoluminal method for gastrotomy closure in NOTES.

    PubMed

    Lee, Sang Soo; Oelschlager, Brant K; Wright, Andrew S; Soares, Renato V; Sinan, Huseyin; Montenovo, Martin I; Hwang, Joo Ha

    2011-10-01

    A reliable method for gastrotomy closure in NOTES will be essential for NOTES to become viable clinically. However, methods using existing and widely available endoscopic accessories have been ineffective. The objective of this study was to evaluate the feasibility and safety of a new simple method for gastric closure (retracted clip-assisted loop closure) that uses existing endoscopic accessories with minor modifications. The retracted clip-assisted loop closure technique involves deploying 3-4 Resolution(®) clips (modified by attaching a 90-cm length of suture to the end of each clip) along the margin of the gastrotomy with one jaw on the serosal surface and the other jaw on the mucosal surface. The suture strings are threaded through an endoloop. Traction is then applied to the strings causing the gastric wall to tent. The endoloop is secured below the tip of the clips, completing a full-thickness gastrotomy closure. The main outcome measures were feasibility, efficacy, and safety of the new retracted clip-assisted loop closure technique for NOTES gastrotomy closure. An air-tight seal was achieved in 100% (n = 9) of stomachs. The mean leak pressure was 116.3 (±19.4) mmHg. The retracted clip-assisted loop closure technique can be used to perform NOTES gastrotomy closure by using existing endoscopic accessories with minor modifications.

  16. Smoking motives in movies are important for understanding adolescent smoking: A preliminary investigation

    PubMed Central

    Martino, Steven C.; Haviland, Amelia; Setodji, Claude; Primack, Brian A.

    2010-01-01

    Introduction: Exposure to smoking in movies is strongly associated with smoking uptake and maintenance among adolescents. However, little is known about what features of movies (e.g., the context for smoking or motives for a character smoking) moderate the association between exposure to movie smoking and adolescent smoking. This laboratory study examined whether exposure to movie smoking that is portrayed as having a clear motive is associated with the desire to smoke differently than smoking that is portrayed as having no clear motive. Methods: A sample of 77 middle school students (mean age of 12.8 years, 62% male, 60% Caucasian) viewed movie clips that portrayed smoking as helping to facilitate social interaction, to relax, to appear rebellious, or as having no clear motive. After exposure to each clip, participants rated their desire to smoke. Results: Exposure to clips where smoking was portrayed as helping characters to relax was associated with a significantly stronger desire to smoke compared with clips where the motive for smoking was unclear. Desire to smoke was similar for clips where no motive was clear, social smoking clips, and rebellious smoking clips. Discussion: These results suggest that the way that smoking is portrayed in movies is important in determining its effect on adolescent smoking. PMID:20576800

  17. Smoking motives in movies are important for understanding adolescent smoking: a preliminary investigation.

    PubMed

    Shadel, William G; Martino, Steven C; Haviland, Amelia; Setodji, Claude; Primack, Brian A

    2010-08-01

    Exposure to smoking in movies is strongly associated with smoking uptake and maintenance among adolescents. However, little is known about what features of movies (e.g., the context for smoking or motives for a character smoking) moderate the association between exposure to movie smoking and adolescent smoking. This laboratory study examined whether exposure to movie smoking that is portrayed as having a clear motive is associated with the desire to smoke differently than smoking that is portrayed as having no clear motive. A sample of 77 middle school students (mean age of 12.8 years, 62% male, 60% Caucasian) viewed movie clips that portrayed smoking as helping to facilitate social interaction, to relax, to appear rebellious, or as having no clear motive. After exposure to each clip, participants rated their desire to smoke. Exposure to clips where smoking was portrayed as helping characters to relax was associated with a significantly stronger desire to smoke compared with clips where the motive for smoking was unclear. Desire to smoke was similar for clips where no motive was clear, social smoking clips, and rebellious smoking clips. These results suggest that the way that smoking is portrayed in movies is important in determining its effect on adolescent smoking.

  18. Anticipation of high arousal aversive and positive movie clips engages common and distinct neural substrates

    PubMed Central

    Carlson, Joshua M.; Rubin, Denis; Cha, Jiook; Mujica-Parodi, Lilianne

    2015-01-01

    The neural correlates of anxious anticipation have been primarily studied with aversive and neutral stimuli. In this study, we examined the effect of valence on anticipation by using high arousal aversive and positive stimuli and a condition of uncertainty (i.e. either positive or aversive). The task consisted of predetermined cues warning participants of upcoming aversive, positive, ‘uncertain’ (either aversive or positive) and neutral movie clips. Anticipation of all affective clips engaged common regions including the anterior insula, dorsal anterior cingulate cortex, thalamus, caudate, inferior parietal and prefrontal cortex that are associated with emotional experience, sustained attention and appraisal. In contrast, the nucleus accumbens and medial prefrontal cortex, regions implicated in reward processing, were selectively engaged during anticipation of positive clips (depicting sexually explicit content) and the mid-insula, which has been linked to processing aversive stimuli, was selectively engaged during anticipation of aversive clips (depicting graphic medical procedures); these three areas were also activated during anticipation of ‘uncertain’ clips reflecting a broad preparatory response for both aversive and positive stimuli. These results suggest that a common circuitry is recruited in anticipation of affective clips regardless of valence, with additional areas preferentially engaged depending on whether expected stimuli are negative or positive. PMID:24984958

  19. The utility of dual-energy CT for metal artifact reduction from intracranial clipping and coiling.

    PubMed

    Mera Fernández, D; Santos Armentia, E; Bustos Fiore, A; Villanueva Campos, A M; Utrera Pérez, E; Souto Bayarri, M

    2018-04-23

    To assess the ability of dual-energy CT (DECT) to reduce metal-related artifacts in patients with clips and coils in head CT angiography, and to analyze the differences in this reduction between both type of devices. Thirteen patients (6 clips, 7 coils) were selected and retrospectively analized. Virtual monoenergetic images (MEI) with photon energies from 40 to 150 keV were obtained. Noise was measured at the area of maximum artifact. Subjective evaluation of streak artifact was performed by two radiologists independently. Differences between noise values in all groups were tested by using the ANOVA test. Mann-Whitney U test was used to compare the differences between clips and coils. Coheńs κ statistic was used to determine interobserver agreement. The lowest noise value was observed at high energy levels (p<0,05). Noise was higher in the coil group than in the clip group (p<0.001). Interobserver agreement was good (κ=0.72). TCED with MEI helps to minimize the artifact from clips ands coils in patients who undergo head CT angiography. The reduction of the artifact is greater in patients with surgical clipping than in patients with endovascular coiling. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Mammographic Density Phenotypes and Risk of Breast Cancer: A Meta-analysis

    PubMed Central

    Graff, Rebecca E.; Ursin, Giske; dos Santos Silva, Isabel; McCormack, Valerie; Baglietto, Laura; Vachon, Celine; Bakker, Marije F.; Giles, Graham G.; Chia, Kee Seng; Czene, Kamila; Eriksson, Louise; Hall, Per; Hartman, Mikael; Warren, Ruth M. L.; Hislop, Greg; Chiarelli, Anna M.; Hopper, John L.; Krishnan, Kavitha; Li, Jingmei; Li, Qing; Pagano, Ian; Rosner, Bernard A.; Wong, Chia Siong; Scott, Christopher; Stone, Jennifer; Maskarinec, Gertraud; Boyd, Norman F.; van Gils, Carla H.

    2014-01-01

    Background Fibroglandular breast tissue appears dense on mammogram, whereas fat appears nondense. It is unclear whether absolute or percentage dense area more strongly predicts breast cancer risk and whether absolute nondense area is independently associated with risk. Methods We conducted a meta-analysis of 13 case–control studies providing results from logistic regressions for associations between one standard deviation (SD) increments in mammographic density phenotypes and breast cancer risk. We used random-effects models to calculate pooled odds ratios and 95% confidence intervals (CIs). All tests were two-sided with P less than .05 considered to be statistically significant. Results Among premenopausal women (n = 1776 case patients; n = 2834 control subjects), summary odds ratios were 1.37 (95% CI = 1.29 to 1.47) for absolute dense area, 0.78 (95% CI = 0.71 to 0.86) for absolute nondense area, and 1.52 (95% CI = 1.39 to 1.66) for percentage dense area when pooling estimates adjusted for age, body mass index, and parity. Corresponding odds ratios among postmenopausal women (n = 6643 case patients; n = 11187 control subjects) were 1.38 (95% CI = 1.31 to 1.44), 0.79 (95% CI = 0.73 to 0.85), and 1.53 (95% CI = 1.44 to 1.64). After additional adjustment for absolute dense area, associations between absolute nondense area and breast cancer became attenuated or null in several studies and summary odds ratios became 0.82 (95% CI = 0.71 to 0.94; P heterogeneity = .02) for premenopausal and 0.85 (95% CI = 0.75 to 0.96; P heterogeneity < .01) for postmenopausal women. Conclusions The results suggest that percentage dense area is a stronger breast cancer risk factor than absolute dense area. Absolute nondense area was inversely associated with breast cancer risk, but it is unclear whether the association is independent of absolute dense area. PMID:24816206

  1. Directly relating gas-phase cluster measurements to solution-phase hydrolysis, the absolute standard hydrogen electrode potential, and the absolute proton solvation energy.

    PubMed

    Donald, William A; Leib, Ryan D; O'Brien, Jeremy T; Williams, Evan R

    2009-06-08

    Solution-phase, half-cell potentials are measured relative to other half-cell potentials, resulting in a thermochemical ladder that is anchored to the standard hydrogen electrode (SHE), which is assigned an arbitrary value of 0 V. A new method for measuring the absolute SHE potential is demonstrated in which gaseous nanodrops containing divalent alkaline-earth or transition-metal ions are reduced by thermally generated electrons. Energies for the reactions 1) M(H(2)O)(24)(2+)(g) + e(-)(g)-->M(H(2)O)(24)(+)(g) and 2) M(H(2)O)(24)(2+)(g) + e(-)(g)-->MOH(H(2)O)(23)(+)(g) + H(g) and the hydrogen atom affinities of MOH(H(2)O)(23)(+)(g) are obtained from the number of water molecules lost through each pathway. From these measurements on clusters containing nine different metal ions and known thermochemical values that include solution hydrolysis energies, an average absolute SHE potential of +4.29 V vs. e(-)(g) (standard deviation of 0.02 V) and a real proton solvation free energy of -265 kcal mol(-1) are obtained. With this method, the absolute SHE potential can be obtained from a one-electron reduction of nanodrops containing divalent ions that are not observed to undergo one-electron reduction in aqueous solution.

  2. Directly Relating Gas-Phase Cluster Measurements to Solution-Phase Hydrolysis, the Absolute Standard Hydrogen Electrode Potential, and the Absolute Proton Solvation Energy

    PubMed Central

    Donald, William A.; Leib, Ryan D.; O’Brien, Jeremy T.; Williams, Evan R.

    2009-01-01

    Solution-phase, half-cell potentials are measured relative to other half-cell potentials, resulting in a thermochemical ladder that is anchored to the standard hydrogen electrode (SHE), which is assigned an arbitrary value of 0 V. A new method for measuring the absolute SHE potential is demonstrated in which gaseous nanodrops containing divalent alkaline-earth or transition-metal ions are reduced by thermally generated electrons. Energies for the reactions 1) M-(H2O)242+(g)+e−(g)→M(H2O)24+(g) and 2) M(H2O)242+(g)+e−(g)→MOH(H2O)23+(g)+H(g) and the hydrogen atom affinities of MOH(H2O)23+(g) are obtained from the number of water molecules lost through each pathway. From these measurements on clusters containing nine different metal ions and known thermochemical values that include solution hydrolysis energies, an average absolute SHE potential of +4.29 V vs. e−(g) (standard deviation of 0.02 V) and a real proton solvation free energy of −265 kcal mol−1 are obtained. With this method, the absolute SHE potential can be obtained from a one-electron reduction of nanodrops containing divalent ions that are not observed to undergo one-electron reduction in aqueous solution. PMID:19440999

  3. Sympathetic block by metal clips may be a reversible operation.

    PubMed

    Thomsen, Lars L; Mikkelsen, Rasmus T; Derejko, Miroslawa; Schrøder, Henrik D; Licht, Peter B

    2014-12-01

    Thoracoscopic sympathectomy is now used routinely to treat patients with disabling primary hyperhidrosis or facial blushing. Published results are excellent, but side effects, such as compensatory sweating, are also very frequent. The surgical techniques used and the levels of targeting the sympathetic chain vary tremendously. Most surgeons transect or resect the sympathetic chain, but application of a metal clip that blocks transmission of nerve impulses in the sympathetic chain is used increasingly worldwide. This approach offers potential reversibility if patients regret surgery, but the question of reversibility remains controversial. Two recent experimental studies found severe histological signs of nerve damage 4-6 weeks after clip removal, but they only used conventional histopathological staining methods. Thoracoscopic clipping of the sympathetic trunk was performed in adult sheep, and the clip was removed thoracoscopically after 7 days. Following another 4 weeks (n = 6) or 12 weeks (n = 3), the sympathetic trunks were harvested and analysed by conventional and specific nerve tissue immunohistochemical stains (S100, neurofilament protein and synaptophysin). The contralateral sympathetic chains were used as controls. Conventional and immunohistochemical stains demonstrated severe signs of neural damage on the operated side 4 weeks after clip removal. After 12 weeks, these changes had decreased markedly and conventional histology had almost normalized. Conventional and immunohistochemical stains confirmed that application of metal clips to the sympathetic chain caused severe histological damage in the sympathetic trunk that remained visible 4 weeks after clip removal. However, after 12 weeks, these signs of damage had clearly decreased, which suggests in theory that application of metal clips to the sympathetic chain is a reversible procedure if only the observation period is prolonged. Further studies with longer periods between application and removal as well as investigations of nerve conduction should be encouraged, because we do not know whether histological reversibility at cellular level translates into physiological reversibility and possible correlation of nerve trauma with the duration of the applied clip. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. CLIPS, AppleEvents, and AppleScript: Integrating CLIPS with commercial software

    NASA Technical Reports Server (NTRS)

    Compton, Michael M.; Wolfe, Shawn R.

    1994-01-01

    Many of today's intelligent systems are comprised of several modules, perhaps written in different tools and languages, that together help solve the user's problem. These systems often employ a knowledge-based component that is not accessed directly by the user, but instead operates 'in the background' offering assistance to the user as necessary. In these types of modular systems, an efficient, flexible, and eady-to-use mechanism for sharing data between programs is crucial. To help permit transparent integration of CLIPS with other Macintosh applications, the AI Research Branch at NASA Ames Research Center has extended CLIPS to allow it to communicate transparently with other applications through two popular data-sharing mechanisms provided by the Macintosh operating system: Apple Events (a 'high-level' event mechanism for program-to-program communication), and AppleScript, a recently-released scripting language for the Macintosh. This capability permits other applications (running on either the same or a remote machine) to send a command to CLIPS, which then responds as if the command were typed into the CLIPS dialog window. Any result returned by the command is then automatically returned to the program that sent it. Likewise, CLIPS can send several types of Apple Events directly to other local or remote applications. This CLIPS system has been successfully integrated with a variety of commercial applications, including data collection programs, electronics forms packages, DBMS's, and email programs. These mechanisms can permit transparent user access to the knowledge base from within a commercial application, and allow a single copy of the knowledge base to service multiple users in a networked environment.

  5. Retreatment of Recurrent Internal Carotid-Posterior Communicating Artery Aneurysm after Coil Embolization

    PubMed Central

    TOYOTA, Shingo; TAKI, Takuyu; WAKAYAMA, Akatsuki; YOSHIMINE, Toshiki

    2015-01-01

    Internal carotid-posterior communicating artery (IC-PC) aneurysms account for more than 20% of all intracranial aneurysms. As a result of the increase in coiling, there has also been an increase in recurrent IC-PC aneurysms after coiling. We present our experience of 10 recurrent IC-PC aneurysms after coiling that were retreated using surgical or endovascular techniques in order to discuss the choice of treatment and the points of clipping without removal of coils. From 2007 to 2014, 10 recurrent IC-PC aneurysms after coiling were retreated. When the previous frames covered the aneurysms all around or almost around except a part of the neck, coiling was chosen. In other cases, clipping was chosen. Clipping was attempted without removal of coils when it was technically feasible. Among the 10 IC-PC aneurysms retreated, 3 were retreated with coiling and 7 were retreated with clipping. In all three cases retreated with coiling, almost complete occlusion was accomplished. In the seven cases retreated with clipping, coil extrusion was observed during surgery in six cases. In most of them, it was necessary to dissect strong adhesions around the coiled aneurysms and to utilize temporary occlusion of the internal carotid artery. In all seven cases, neck clipping was accomplished without the removal of coils. There were no neurological complications in any cases. The management of recurrent lesions of embolized IC-PC aneurysms requires appropriate choice of treatment using both coiling and clipping. Clipping, especially without the removal of coils, plays an important role in safe treatment. PMID:26437796

  6. Retreatment of Recurrent Internal Carotid-Posterior Communicating Artery Aneurysm after Coil Embolization.

    PubMed

    Toyota, Shingo; Taki, Takuyu; Wakayama, Akatsuki; Yoshimine, Toshiki

    2015-01-01

    Internal carotid-posterior communicating artery (IC-PC) aneurysms account for more than 20% of all intracranial aneurysms. As a result of the increase in coiling, there has also been an increase in recurrent IC-PC aneurysms after coiling. We present our experience of 10 recurrent IC-PC aneurysms after coiling that were retreated using surgical or endovascular techniques in order to discuss the choice of treatment and the points of clipping without removal of coils. From 2007 to 2014, 10 recurrent IC-PC aneurysms after coiling were retreated. When the previous frames covered the aneurysms all around or almost around except a part of the neck, coiling was chosen. In other cases, clipping was chosen. Clipping was attempted without removal of coils when it was technically feasible. Among the 10 IC-PC aneurysms retreated, 3 were retreated with coiling and 7 were retreated with clipping. In all three cases retreated with coiling, almost complete occlusion was accomplished. In the seven cases retreated with clipping, coil extrusion was observed during surgery in six cases. In most of them, it was necessary to dissect strong adhesions around the coiled aneurysms and to utilize temporary occlusion of the internal carotid artery. In all seven cases, neck clipping was accomplished without the removal of coils. There were no neurological complications in any cases. The management of recurrent lesions of embolized IC-PC aneurysms requires appropriate choice of treatment using both coiling and clipping. Clipping, especially without the removal of coils, plays an important role in safe treatment.

  7. Zirconia-Polyurethane Aneurysm Clip.

    PubMed

    Cho, Won-Sang; Cho, Kyung-Il; Kim, Jeong Eun; Jang, Tae-Sik; Ha, Eun Jin; Kang, Hyun-Seung; Son, Young-Je; Choi, Seung Hong; Lee, Seunghyun; Kim, Chong-Chan; Sun, Jeong-Yun; Kim, Hyoun-Ee

    2018-03-27

    Susceptibility artifacts from metal clips in magnetic resonance (MR) imaging present an obstacle to evaluating the status of clipped aneurysms, parent arteries and adjacent brain parenchyma. We aimed to develop MR-compatible aneurysm clips. Considering the mechanical and biological properties, and MR compatibility of candidate materials, a prototype clip with a zirconia body and a polyurethane head spring (ZC, straight, 9-mm long) was developed. The closing forces, opening width of blades, and in vitro and in vivo artifact volumes in 3 tesla MR imaging were compared among the prototype and commercial metal clips such as a Yasargil ® clip (YC, curved type, 8.3-mm long) and a Sugita ® clip (SC, straight type, 10-mm long). An in vivo animal study was performed with a canine venous pouch aneurysm model. The closing forces (N) at 1 and 8 mm from the blade tip were 2.09 and 3.77 in YC, 1.85 and 3.04 in SC, and 2.05 and 4.60 in ZC. The maximum opening widths (mm) was 6.8, 9.0, and 3.0 in YC, SC, and ZC, respectively. The in vitro artifact volumes of YC, SC and ZC in time-of-flight MR imaging were 26.9, 29.7 and 1.9 times larger than the respective real volumes. The in vivo artifact volumes of YC, SC, and ZC were respectively 21.4, 29.4, and 2.6 times larger than real ones. ZC showed the smallest susceptibility artifacts and satisfactory closing forces. However, the narrow opening width of the blades was a weak point. Copyright © 2018. Published by Elsevier Inc.

  8. Hem-o-lok clip: a neglected cause of severe bladder neck contracture and consequent urinary incontinence after robot-assisted laparoscopic radical prostatectomy.

    PubMed

    Cormio, Luigi; Massenio, Paolo; Lucarelli, Giuseppe; Di Fino, Giuseppe; Selvaggio, Oscar; Micali, Salvatore; Carrieri, Giuseppe

    2014-02-20

    Hem-o-lok clips are widely used during robot-assisted and laparoscopic radical prostatectomy to control the lateral pedicles. There are a few reports of hem-o-lok clip migration into the bladder or vesico-urethral anastomosis and only four cases of hem-o-lok clip migration resulting into bladder neck contracture. Herein, we describe the first case, to our knowledge, of hem-o-lok clip migration leading to severe bladder neck contracture and subsequent stress urinary incontinence. A 62-year-old Caucasian man underwent robot-assisted laparoscopic radical prostatectomy for a T1c Gleason 8 prostate cancer. One month after surgery the patient was fully continent; however, three months later, he presented with acute urinary retention requiring suprapubic drainage. Urethroscopy showed a hem-o-lok clip strongly attached to the area between the vesico-urethral anastomosis and the urethral sphincter and a severe bladder neck contracture behind it. Following cold-knife urethral incision and clip removal, the bladder neck contracture was widely resected. At 3-month follow-up, the patient voided spontaneously with a peak flow rate of 9.5 ml/sec and absence of post-void residual urine, but leaked 240 ml urine at the 24-hour pad test. To date, at 1-year follow-up, his voiding situation remains unchanged. The present report provides further evidence for the risk of hem-o-lok clip migration causing bladder neck contracture, and is the first to demonstrate the potential of such complication to result into stress urinary incontinence.

  9. Impulsivity moderates the effects of movie alcohol portrayals on adolescents' willingness to drink.

    PubMed

    Gibbons, Frederick X; Kingsbury, John H; Wills, Thomas A; Finneran, Stephanie D; Dal Cin, Sonya; Gerrard, Meg

    2016-05-01

    This study examined impulsivity as a moderator of adolescents' reactions to positive versus negative portrayals of drinking in American movie clips. Impulsivity, along with willingness and intentions to drink in the future, were assessed in a pretest session. In the experimental sessions, adolescents viewed a series of clips that showed drinking associated with either positive outcomes (e.g., social facilitation) or negative outcomes (fights, arguments). A third group viewed clips with similar positive or negative outcomes, but no alcohol consumption. All participants then responded to an implicit measure of attentional bias regarding alcohol (a dot probe), followed by explicit alcohol measures (self-reports of willingness and intentions to drink). Hypotheses, based on dual-processing theories, were: (a) high-impulsive adolescents would respond more favorably than low-impulsive adolescents to the positive clips, but not the negative clips; and (b) this difference in reactions to the positive clips would be larger on the willingness than the intention measures. Results supported the hypotheses: Adolescents high in impulsivity reported the highest willingness to drink in the positive-clip condition, but were slightly less willing than others in the negative-clip condition. In addition, results on the dot probe task indicated that RTs to alcohol words were negatively correlated with changes in alcohol willingness, but not intention; that is, the faster their response to the alcohol words, the more their willingness increased. The results highlight the utility of a dual-processing perspective on media influence. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  10. Fabrication and Characterization of ZnO Nano-Clips by the Polyol-Mediated Process

    NASA Astrophysics Data System (ADS)

    Wang, Mei; Li, Ai-Dong; Kong, Ji-Zhou; Gong, You-Pin; Zhao, Chao; Tang, Yue-Feng; Wu, Di

    2018-02-01

    ZnO nano-clips with better monodispersion were prepared successfully using zinc acetate hydrate (Zn(OAc)2·nH2O) as Zn source and ethylene glycol (EG) as solvent by a simple solution-based route-polyol process. The effect of solution concentration on the formation of ZnO nano-clips has been investigated deeply. We first prove that the 0.01 M Zn(OAc)2·nH2O can react with EG without added water or alkaline, producing ZnO nano-clips with polycrystalline wurtzite structure at 170 °C. As-synthesized ZnO nano-clips contain a lot of aggregated nanocrystals ( 5 to 15 nm) with high specific surface area of 88 m2/g. The shapes of ZnO nano-clips basically keep constant with improved crystallinity after annealing at 400-600 °C. The lower solution concentration and slight amount of H2O play a decisive role in ZnO nano-clip formation. When the solution concentration is ≤ 0.0125 M, the complexing and polymerization reactions between Zn(OAc)2·nH2O and EG predominate, mainly elaborating ZnO nano-clips. When the solution concentration is ≥ 0.015 M, the alcoholysis and polycondensation reactions of Zn(OAc)2·nH2O and EG become dominant, leading to ZnO particle formation with spherical and elliptical shapes. The possible growth mechanism based on a competition between complexing and alcoholysis of Zn(OAc)2·nH2O and EG has been proposed.

  11. A clip domain serine protease involved in moulting in the silkworm, Bombyx mori: cloning, characterization, expression patterns and functional analysis.

    PubMed

    Liu, H-W; Wang, L-L; Meng, Z; Tang, X; Li, Y-S; Xia, Q-Y; Zhao, P

    2017-10-01

    Clip domain serine proteases (CLIPs), characterized by one or more conserved clip domains, are essential components of extracellular signalling cascades in various biological processes, especially in innate immunity and the embryonic development of insects. Additionally, CLIPs may have additional non-immune functions in insect development. In the present study, the clip domain serine protease gene Bombyx mori serine protease 95 (BmSP95), which encodes a 527-residue protein, was cloned from the integument of B. mori. Bioinformatics analysis indicated that BmSP95 is a typical CLIP of the subfamily D and possesses a clip domain at the N terminus, a trypsin-like serine protease (tryp_spc) domain at the C terminus and a conserved proline-rich motif between these two domains. At the transcriptional level, BmSP95 is expressed in the integument during moulting and metamorphosis, and the expression pattern is consistent with the fluctuating 20-hydroxyecdysone (20E) titre in B. mori. At the translational level, BmSP95 protein is synthesized in the epidermal cells, secreted as a zymogen and activated in the moulting fluid. Immunofluorescence revealed that BmSP95 is distributed into the old endocuticle in the moulting stage. The expression of BmSP95 was upregulated by 20E. Moreover, expression of BmSP95 was downregulated by pathogen infection. RNA interference-mediated silencing of BmSP95 led to delayed moulting from pupa to moth. These results suggest that BmSP95 is involved in integument remodelling during moulting and metamorphosis. © 2017 The Royal Entomological Society.

  12. Intensity stabilisation of optical pulse sequences for coherent control of laser-driven qubits

    NASA Astrophysics Data System (ADS)

    Thom, Joseph; Yuen, Ben; Wilpers, Guido; Riis, Erling; Sinclair, Alastair G.

    2018-05-01

    We demonstrate a system for intensity stabilisation of optical pulse sequences used in laser-driven quantum control of trapped ions. Intensity instability is minimised by active stabilisation of the power (over a dynamic range of > 104) and position of the focused beam at the ion. The fractional Allan deviations in power were found to be <2.2 × 10^{-4} for averaging times from 1 to 16,384 s. Over similar times, the absolute Allan deviation of the beam position is <0.1 μm for a 45 {μ }m beam diameter. Using these residual power and position instabilities, we estimate the associated contributions to infidelity in example qubit logic gates to be below 10^{-6} per gate.

  13. Using Humorous Sitcom Clips in Teaching Federal Income Taxes

    ERIC Educational Resources Information Center

    Cecil, H. Wayne

    2014-01-01

    This article shares the motivation, process, and outcomes of using humorous scenes from television comedies to teach the real world of tax practice. The article advances the literature by reviewing the use of video clips in a previously unexplored discipline, discussing the process of identifying and selecting appropriate clips, and introducing…

  14. Assessment of Caudal Fin Clips as a Non-lethal Technique for Predicting Muscle Tissue Mercury Concentrations in Largeouth Bass

    EPA Science Inventory

    The statistical relationship between total mercury (Hg) concentration in clips from the caudal fin and muscle tissue of largemouth bass (Micropterus salmoides) from 26 freshwater sites in Rhode Island, USA was developed and evaluated to determine the utility of fin clip analysis ...

  15. Capturing Students' Attention: Movie Clips Set the Stage for Learning in Abnormal Psychology.

    ERIC Educational Resources Information Center

    Badura, Amy S.

    2002-01-01

    Presents results of a study that evaluated using popular movie clips, shown in the first class meeting of an abnormal psychology course, in relation to student enthusiasm. Compares two classes of female juniors, one using clips and one class not using them. States that the films portrayed psychological disorders. (CMK)

  16. First CLIPS Conference Proceedings, volume 2

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The topics of volume 2 of First CLIPS Conference are associated with following applications: quality control; intelligent data bases and networks; Space Station Freedom; Space Shuttle and satellite; user interface; artificial neural systems and fuzzy logic; parallel and distributed processing; enchancements to CLIPS; aerospace; simulation and defense; advisory systems and tutors; and intelligent control.

  17. Mapping Argonaute and conventional RNA-binding protein interactions with RNA at single-nucleotide resolution using HITS-CLIP and CIMS analysis

    PubMed Central

    Moore, Michael; Zhang, Chaolin; Gantman, Emily Conn; Mele, Aldo; Darnell, Jennifer C.; Darnell, Robert B.

    2014-01-01

    Summary Identifying sites where RNA binding proteins (RNABPs) interact with target RNAs opens the door to understanding the vast complexity of RNA regulation. UV-crosslinking and immunoprecipitation (CLIP) is a transformative technology in which RNAs purified from in vivo cross-linked RNA-protein complexes are sequenced to reveal footprints of RNABP:RNA contacts. CLIP combined with high throughput sequencing (HITS-CLIP) is a generalizable strategy to produce transcriptome-wide RNA binding maps with higher accuracy and resolution than standard RNA immunoprecipitation (RIP) profiling or purely computational approaches. Applying CLIP to Argonaute proteins has expanded the utility of this approach to mapping binding sites for microRNAs and other small regulatory RNAs. Finally, recent advances in data analysis take advantage of crosslinked-induced mutation sites (CIMS) to refine RNA-binding maps to single-nucleotide resolution. Once IP conditions are established, HITS-CLIP takes approximately eight days to prepare RNA for sequencing. Established pipelines for data analysis, including for CIMS, take 3-4 days. PMID:24407355

  18. Endoscopic removal of over-the-scope clips using a novel cutting device: a retrospective case series.

    PubMed

    Schmidt, Arthur; Riecken, Bettina; Damm, Michael; Cahyadi, Oscar; Bauder, Markus; Caca, Karel

    2014-09-01

    Over-the-scope clips (OTSCs; Ovesco Endoscopy, Tübingen, Germany) are extensively used for treatment of gastrointestinal perforations, leakages, fistulas, and bleeding. In this report, a new method of removing OTSCs using a prototype bipolar cutting device is described. A total of 11 patients underwent endoscopic removal of an OTSC. The OTSC was cut at two opposing sites by a prototype device (DC ClipCutter; Ovesco Endoscopy). The remaining clip fragments were extracted using a standard forceps. Mean procedure time was 47 minutes (range 35 - 75 minutes). Cutting of the OTSC at two opposing sites was successful in all cases (100 %). Complete retrieval of all clip fragments was possible in 10 patients (91 %). The overall success rate for cutting and complete removal of the clip was 91 %. No major complications were observed. Removal of OTSCs with the prototype device was feasible and effective. The device may be valuable for OTSC removal in emergency as well as elective indications. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Analysis of left atrial respiratory and cardiac motion for cardiac ablation therapy

    NASA Astrophysics Data System (ADS)

    Rettmann, M. E.; Holmes, D. R.; Johnson, S. B.; Lehmann, H. I.; Robb, R. A.; Packer, D. L.

    2015-03-01

    Cardiac ablation therapy is often guided by models built from preoperative computed tomography (CT) or magnetic resonance imaging (MRI) scans. One of the challenges in guiding a procedure from a preoperative model is properly synching the preoperative models with cardiac and respiratory motion through computational motion models. In this paper, we describe a methodology for evaluating cardiac and respiratory motion in the left atrium and pulmonary veins of a beating canine heart. Cardiac catheters were used to place metal clips within and near the pulmonary veins and left atrial appendage under fluoroscopic and ultrasound guidance and a contrast-enhanced, 64-slice multidetector CT scan was collected with the clips in place. Each clip was segmented from the CT scan at each of the five phases of the cardiac cycle at both end-inspiration and end-expiration. The centroid of each segmented clip was computed and used to evaluate both cardiac and respiratory motion of the left atrium. A total of three canine studies were completed, with 4 clips analyzed in the first study, 5 clips in the second study, and 2 clips in the third study. Mean respiratory displacement was 0.2+/-1.8 mm in the medial/lateral direction, 4.7+/-4.4 mm in the anterior/posterior direction (moving anterior on inspiration), and 9.0+/-5.0 mm superior/inferior (moving inferior with inspiration). At end inspiration, the mean left atrial cardiac motion at the clip locations was 1.5+/-1.3 mm in the medial/lateral direction, and 2.1+/-2.0 mm in the anterior/posterior and 1.3+/-1.2 mm superior/inferior directions. At end expiration, the mean left atrial cardiac motion at the clip locations was 2.0+/-1.5mm in the medial/lateral direction, 3.0+/-1.8mm in the anterior/posterior direction, and 1.5+/-1.5 mm in the superior/inferior directions.

  20. Public Awareness of Melioidosis in Thailand and Potential Use of Video Clips as Educational Tools

    PubMed Central

    Chansrichavala, Praveen; Wongsuwan, Nittayasee; Suddee, Suthee; Malasit, Mayura; Hongsuwan, Maliwan; Wannapinij, Prapass; Kitphati, Rungreung; Day, Nicholas P. J.; Michie, Susan; Peacock, Sharon J.; Limmathurotsakul, Direk

    2015-01-01

    Background Melioidosis causes more than 1,000 deaths in Thailand each year. Infection occurs via inoculation, ingestion or inhalation of the causative organism (Burkholderia pseuodmallei) present in soil and water. Here, we evaluated public awareness of melioidosis using a combination of population-based questionnaire, a public engagement campaign to obtain video clips made by the public, and viewpoints on these video clips as potential educational tools about the disease and its prevention. Methods A questionnaire was developed to evaluate public awareness of melioidosis, and knowledge about its prevention. From 1 March to 31 April 2012, the questionnaire was delivered to five randomly selected adults in each of 928 districts in Thailand. A video clip contest entitled “Melioidosis, an infectious disease that Thais must know” was run between May and October 2012. The best 12 video clips judged by a contest committee were shown to 71 people at risk from melioidosis (diabetics). Focus group interviews were used to evaluate their perceptions of the video clips. Results Of 4,203 Thais who completed our study questionnaire, 74% had never heard of melioidosis, and 19% had heard of the disease but had no further knowledge. Most participants in all focus group sessions felt that video clips were beneficial and could positively influence them to increase adherence to recommended preventive behaviours, including drinking boiled water and wearing protective gear if in contact with soil or environmental water. Participants suggested that video clips should be presented in the local dialect with simple words rather than medical terms, in a serious manner, with a doctor as the one presenting the facts, and having detailed pictures of each recommended prevention method. Conclusions In summary, public awareness of melioidosis in Thailand is very low, and video clips could serve as a useful medium to educate people and promote disease prevention. Presented in Part World Melioidosis Congress 2013, Bangkok, Thailand, 18–20 September 2013 (abstract OS VII-04). PMID:25803048

  1. A Systematic Review and Meta-Analysis on Economic Comparison Between Endovascular Coiling Versus Neurosurgical Clipping for Ruptured Intracranial Aneurysms.

    PubMed

    Zhang, Xiaoxi; Li, Li; Hong, Bo; Xu, Yi; Liu, Yuan; Huang, Qinghai; Liu, Jianmin

    2018-05-01

    Healthcare expenditures and cost reduction have been under critical surveillance in all countries and are critical for policymakers. This review aims at qualitatively and quantitatively analyzing the difference of hospital costs and length of stay between endovascular coiling versus neurosurgical clipping in ruptured intracranial aneurysms (RAs). MEDLINE, the Cochrane database, Embase, and the Web of Science database were searched and evaluated independently by 2 authors according to the Newcastle-Ottawa Scale for cohort studies describing economic hospital cost or length of stay in patients with RAs. A total of 8 studies were included, describing 24,219 RAs treated with neurosurgical clipping and 24,962 RAs with endovascular coiling. Meta-analysis revealed that the total hospital costs (THCs) were similar between coiling versus clipping in RAs (standard mean difference [SMD], -0.05; 95% confidence interval [CI], -0.12 to 0.22; I 2  = 99%; P = 0.50). Subgroup analysis showed that THCs of clipping and coiling were similar in ruptured aneurysms in the United States. However, in South Korea, the THCs of coiling were significantly higher than clipping. In the long run, 1-year medical costs of endovascular treatment were significantly lower than that of clipping in RAs (SMD, 0.15; 95% CI, 0.05-0.25; I 2  = 66%; P = 0.005). In addition, the length of stay of coiled patients was significantly shorter than clipped patients (SMD, 0.29; 95% CI, 0.13-0.45; I 2  = 96%; P < 0.001). Medical costs were region-specified. In the United States, total hospital costs and 1-year medical costs were similar in RA patients treated with endovascular coiling and neurosurgical clipping. However, in countries like South Korea and China, coiling was more expensive. The length of stay was much shorter in coiled patients in all countries. Copyright © 2018. Published by Elsevier Inc.

  2. Preoperative simulation for the planning of microsurgical clipping of intracranial aneurysms.

    PubMed

    Marinho, Paulo; Vermandel, Maximilien; Bourgeois, Philippe; Lejeune, Jean-Paul; Mordon, Serge; Thines, Laurent

    2014-12-01

    The safety and success of intracranial aneurysm (IA) surgery could be improved through the dedicated application of simulation covering the procedure from the 3-dimensional (3D) description of the surgical scene to the visual representation of the clip application. We aimed in this study to validate the technical feasibility and clinical relevance of such a protocol. All patients preoperatively underwent 3D magnetic resonance imaging and 3D computed tomography angiography to build 3D reconstructions of the brain, cerebral arteries, and surrounding cranial bone. These 3D models were segmented and merged using Osirix, a DICOM image processing application. This provided the surgical scene that was subsequently imported into Blender, a modeling platform for 3D animation. Digitized clips and appliers could then be manipulated in the virtual operative environment, allowing the visual simulation of clipping. This simulation protocol was assessed in a series of 10 IAs by 2 neurosurgeons. The protocol was feasible in all patients. The visual similarity between the surgical scene and the operative view was excellent in 100% of the cases, and the identification of the vascular structures was accurate in 90% of the cases. The neurosurgeons found the simulation helpful for planning the surgical approach (ie, the bone flap, cisternal opening, and arterial tree exposure) in 100% of the cases. The correct number of final clip(s) needed was predicted from the simulation in 90% of the cases. The preoperatively expected characteristics of the optimal clip(s) (ie, their number, shape, size, and orientation) were validated during surgery in 80% of the cases. This study confirmed that visual simulation of IA clipping based on the processing of high-resolution 3D imaging can be effective. This is a new and important step toward the development of a more sophisticated integrated simulation platform dedicated to cerebrovascular surgery.

  3. Phytoremediation of palm oil mill secondary effluent (POMSE) by Chrysopogon zizanioides (L.) using artificial neural networks.

    PubMed

    Darajeh, Negisa; Idris, Azni; Fard Masoumi, Hamid Reza; Nourani, Abolfazl; Truong, Paul; Rezania, Shahabaldin

    2017-05-04

    Artificial neural networks (ANNs) have been widely used to solve the problems because of their reliable, robust, and salient characteristics in capturing the nonlinear relationships between variables in complex systems. In this study, ANN was applied for modeling of Chemical Oxygen Demand (COD) and biodegradable organic matter (BOD) removal from palm oil mill secondary effluent (POMSE) by vetiver system. The independent variable, including POMSE concentration, vetiver slips density, and removal time, has been considered as input parameters to optimize the network, while the removal percentage of COD and BOD were selected as output. To determine the number of hidden layer nodes, the root mean squared error of testing set was minimized, and the topologies of the algorithms were compared by coefficient of determination and absolute average deviation. The comparison indicated that the quick propagation (QP) algorithm had minimum root mean squared error and absolute average deviation, and maximum coefficient of determination. The importance values of the variables was included vetiver slips density with 42.41%, time with 29.8%, and the POMSE concentration with 27.79%, which showed none of them, is negligible. Results show that the ANN has great potential ability in prediction of COD and BOD removal from POMSE with residual standard error (RSE) of less than 0.45%.

  4. Who's biased? A meta-analysis of buyer-seller differences in the pricing of lotteries.

    PubMed

    Yechiam, Eldad; Ashby, Nathaniel J S; Pachur, Thorsten

    2017-05-01

    A large body of empirical research has examined the impact of trading perspective on pricing of consumer products, with the typical finding being that selling prices exceed buying prices (i.e., the endowment effect). Using a meta-analytic approach, we examine to what extent the endowment effect also emerges in the pricing of monetary lotteries. As monetary lotteries have a clearly defined normative value, we also assess whether one trading perspective is more biased than the other. We consider several indicators of bias: absolute deviation from expected values, rank correlation with expected values, overall variance, and per-unit variance. The meta-analysis, which includes 35 articles, indicates that selling prices considerably exceed buying prices (Cohen's d = 0.58). Importantly, we also find that selling prices deviate less from the lotteries' expected values than buying prices, both in absolute and in relative terms. Selling prices also exhibit lower variance per unit. Hierarchical Bayesian modeling with cumulative prospect theory indicates that buyers have lower probability sensitivity and a more pronounced response bias. The finding that selling prices are more in line with normative standards than buying prices challenges the prominent account whereby sellers' valuations are upward biased due to loss aversion, and supports alternative theoretical accounts. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. Inter-laboratory validation of bioaccessibility testing for metals.

    PubMed

    Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R

    2014-10-01

    Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. The laminar organization of the motor cortex in monodactylous mammals: a comparative assessment based on horse, chimpanzee, and macaque.

    PubMed

    Cozzi, Bruno; De Giorgio, Andrea; Peruffo, A; Montelli, S; Panin, M; Bombardi, C; Grandis, A; Pirone, A; Zambenedetti, P; Corain, L; Granato, Alberto

    2017-08-01

    The architecture of the neocortex classically consists of six layers, based on cytological criteria and on the layout of intra/interlaminar connections. Yet, the comparison of cortical cytoarchitectonic features across different species proves overwhelmingly difficult, due to the lack of a reliable model to analyze the connection patterns of neuronal ensembles forming the different layers. We first defined a set of suitable morphometric cell features, obtained in digitized Nissl-stained sections of the motor cortex of the horse, chimpanzee, and crab-eating macaque. We then modeled them using a quite general non-parametric data representation model, showing that the assessment of neuronal cell complexity (i.e., how a given cell differs from its neighbors) can be performed using a suitable measure of statistical dispersion such as the mean absolute deviation-mean absolute deviation (MAD). Along with the non-parametric combination and permutation methodology, application of MAD allowed not only to estimate, but also to compare and rank the motor cortical complexity across different species. As to the instances presented in this paper, we show that the pyramidal layers of the motor cortex of the horse are far more irregular than those of primates. This feature could be related to the different organizations of the motor system in monodactylous mammals.

  7. Maintainable substrate carrier for electroplating

    DOEpatents

    Chen, Chen-An [Milpitas, CA; Abas, Emmanuel Chua [Laguna, PH; Divino, Edmundo Anida [Cavite, PH; Ermita, Jake Randal G [Laguna, PH; Capulong, Jose Francisco S [Laguna, PH; Castillo, Arnold Villamor [Batangas, PH; Ma,; Xiaobing, Diana [Saratoga, CA

    2012-07-17

    One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The carrier includes a non-conductive carrier body on which the substrates are placed and conductive lines embedded within the carrier body. A plurality of conductive clip attachment parts are attached in a permanent manner to the conductive lines embedded within the carrier body. A plurality of contact clips are attached in a removable manner to the clip attachment parts. The contact clips hold the substrates in place and conductively connecting the substrates with the conductive lines. Other embodiments, aspects and features are also disclosed.

  8. Maintainable substrate carrier for electroplating

    DOEpatents

    Chen, Chen-An; Abas, Emmanuel Chua; Divino, Edmundo Anida; Ermita, Jake Randal G.; Capulong, Jose Francisco S.; Castillo, Arnold Villamor; Ma, Diana Xiaobing

    2016-08-02

    One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The carrier includes a non-conductive carrier body on which the substrates are placed and conductive lines embedded within the carrier body. A plurality of conductive clip attachment parts are attached in a permanent manner to the conductive lines embedded within the carrier body. A plurality of contact clips are attached in a removable manner to the clip attachment parts. The contact clips hold the substrates in place and conductively connecting the substrates with the conductive lines. Other embodiments, aspects and features are also disclosed.

  9. Anticipation of high arousal aversive and positive movie clips engages common and distinct neural substrates.

    PubMed

    Greenberg, Tsafrir; Carlson, Joshua M; Rubin, Denis; Cha, Jiook; Mujica-Parodi, Lilianne

    2015-04-01

    The neural correlates of anxious anticipation have been primarily studied with aversive and neutral stimuli. In this study, we examined the effect of valence on anticipation by using high arousal aversive and positive stimuli and a condition of uncertainty (i.e. either positive or aversive). The task consisted of predetermined cues warning participants of upcoming aversive, positive, 'uncertain' (either aversive or positive) and neutral movie clips. Anticipation of all affective clips engaged common regions including the anterior insula, dorsal anterior cingulate cortex, thalamus, caudate, inferior parietal and prefrontal cortex that are associated with emotional experience, sustained attention and appraisal. In contrast, the nucleus accumbens and medial prefrontal cortex, regions implicated in reward processing, were selectively engaged during anticipation of positive clips (depicting sexually explicit content) and the mid-insula, which has been linked to processing aversive stimuli, was selectively engaged during anticipation of aversive clips (depicting graphic medical procedures); these three areas were also activated during anticipation of 'uncertain' clips reflecting a broad preparatory response for both aversive and positive stimuli. These results suggest that a common circuitry is recruited in anticipation of affective clips regardless of valence, with additional areas preferentially engaged depending on whether expected stimuli are negative or positive. © The Author (2014). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  10. Anterior petroclinoid fold fenestration: an adjunct to clipping of postero-laterally projecting posterior communicating aneurysms.

    PubMed

    Nossek, Erez; Setton, Avi; Dehdashti, Amir R; Chalif, David J

    2014-10-01

    Proximally located posterior communicating artery (PCoA) aneurysms, projecting postero-laterally in proximity to the tentorium, may pose a technical challenge for microsurgical clipping due to obscuration of the proximal aneurysmal neck by the anterior petroclinoid fold. We describe an efficacious technique utilizing fenestration of the anterior petroclinoid fold to facilitate visualization and clipping of PCoA aneurysms abutting this aspect of the tentorium. Of 86 cases of PCoA aneurysms treated between 2003 and 2013, the technique was used in nine (10.5 %) patients to allow for adequate clipping. A 3 mm fenestration in the anterior petroclinoid ligament is created adjacent and lateral to the anterior clinoid process. This fenestration is then widened into a small wedge corridor by bipolar coagulation. In all cases, the proximal aneurysm neck was visualized after the wedge fenestration. Additionally, an adequate corridor for placement of the proximal clip blade was uniformly established. All cases were adequately clipped, with complete occlusion of the aneurysm neck and fundus with preservation of the PCoA. There were two intraoperative ruptures not related to creation of the wedge fenestration. One patient experienced post-operative partial third nerve palsy, which resolved during follow-up. We describe a technique of fenestration of the anterior petroclinoid fold to establish a critical and safe corridor for both visualization and clipping of PCoA aneurysms.

  11. In-depth statistical analysis of the use of a website providing patients' narratives on lifestyle change when living with chronic back pain or coronary heart disease.

    PubMed

    Schweier, Rebecca; Grande, Gesine; Richter, Cynthia; Riedel-Heller, Steffi G; Romppel, Matthias

    2018-07-01

    To investigate the use of lebensstil-aendern.de ("lifestyle change"), a website providing peer narratives of experiences with successful lifestyle change, and to analyze whether peer model characteristics, clip content, and media type have an influence on the number of visitors, dwell time, and exit rates. An in-depth statistical analysis of website use with multilevel regression analyses. In two years, lebensstil-aendern.de attracted 12,844 visitors. The in-depth statistical analysis of usage rates demonstrated that audio clips were less popular than video or text-only clips, longer clips attracted more visitors, and clips by younger and female interviewees were preferred. User preferences for clip content categories differed between heart and back pain patients. Clips about stress management drew the smallest numbers of visitors in both indication modules. Patients are interested in the experiences of others. Because the quality of information for user-generated content is generally low, healthcare providers should include quality-assured patient narratives in their interventions. User preferences for content, medium, and peer characteristics need to be taken into account. If healthcare providers decide to include patient experiences in their websites, they should plan their intervention according to the different needs and preferences of users. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Effects of endomycorrhizal infection, artificial herbivory, and parental cross on growth of Lotus corniculatus L.

    PubMed

    Borowicz, V A; Fitter, A H

    1990-03-01

    We examined how combinations of parentage, fungicide application, and artificial herbivory influence growth and shoot phosphorus content in pre-reproductive Lotus corniculatus, using young offspring arising from three parental crosses, two of which had one parent in common. Soil with vesicular-arbuscular mycorrhizal (VAM) fungi was treated with either water or benomyl, an anti-VAM fungicide, and added to trays containing groups of four full siblings. There were two experiments; in the first no plants were clipped while in the second two of the four plants were clipped to simulate herbivory. In both experiments plants of the two related crosses accumulated more biomass and total shoot P than did plants of the third cross. Plants inoculated with watertreated soil had greater shoot mass and P concentration than did fungicide-treated replicates but the extent of increase in P concentration varied among crosses. In Experiment 2, clipping reduced root mass and resulted in higher shoot P concentration. In this experiment there was a significant interaction of fungicide application and clipping: both unclipped and clipped plants grew better in soil not treated with fungicide, but the increase in shoot mass, total mass, and total P was greater in unclipped plants. Significant interaction of fungicide treatment and clipping is most likely due to reduced availability of carbon to the roots of clipped plants, resulting in poorer symbiotic functioning.

  13. Heavy metal phytoextraction by Sedum alfredii is affected by continual clipping and phosphorus fertilization amendment.

    PubMed

    Huang, Huagang; Li, Tingqiang; Gupta, D K; He, Zhenli; Yang, Xiao-E; Ni, Bingnan; Li, Mao

    2012-01-01

    Improving the efficacy of phytoextraction is critical for its successful application in metal contaminated soils. Mineral nutrition affects plant growth and metal absorption and subsequently the accumulation of heavy metal through hyper-accumulator plants. This study assessed the effects of di-hydrogen phosphates (KH2PO4, Ca(H2PO4)2, NaH2PO4 and NH4H2PO4) application at three levels (22, 88 and 352 mg P/kg soil) on Sedum alfredii growth and metal uptake by three consecutive harvests on aged and Zn/Cd combined contaminated paddy soil. The addition of phosphates (P) significantly increased the amount of Zn taken up by S. alfredii due to increased shoot Zn concentration and dry matter yield (DMY) (P < 0.05). The highest phytoextraction of Zn and Cd was observed in KH2PO4 and NH4H2PO4 treatment at 352 mg P/kg soil. The amount of Zn removed by phytoextraction increased in the order of 1st clipping < 2nd clipping < 3rd clipping, and for Cd extraction the order was 2nd clipping < 1st clipping < 3rd clipping. These results indicate that the application of P fertilizers coupled with multiple cuttings can enhance the removal of Zn and Cd from contaminated soils by S. alfredii, thus shortening the time needed for accomplishing remediation goals.

  14. Tracking Solar Energy Conersion Unit Adapted For Field Assembly

    DOEpatents

    Kaminar, Neil R.; Ross, III, James G.; Carrie, Peter J.

    2000-02-01

    A modular solar energy collector having elongated V-shaped side walls formed by a pair of coplanar panels for each side wall. The upper panels, occupying most of the wall area are diffusely reflective, but the lower panels are specularly reflective. A Fresnel lens, having a snap fit relation to the side walls focuses some light on the lower specularly reflective panels which direct light to the solar cells at the base of the V-shaped walls. A heat sink provides support for the two panels with two opposed, upwardly extending wings terminating in opposed linear clips located near the lengthwise seam of the coplanar panels, each clip holding two coplanar panels in parallel alignment. The clips not only provide support for the panels, but also transfer heat to the remainder of the heat sink. The clips are shaped so that edges of the panels engage each clip by a snap fit, outside of the clip in one embodiment and inside of the clip in another embodiment. End caps are also formed with structures which snap to the wall panels. Since all junctions of components snap together, the collector of the present invention is easily assembled without specialized tools. Using side walls which are only partly specularly reflective permits a large angle of acceptance, yet provides an economical wall design because the entire wall need not be specularly reflective.

  15. Isobaric vapor-liquid equilibria for binary systems α-phenylethylamine + toluene and α-phenylethylamine + cyclohexane at 100 kPa

    NASA Astrophysics Data System (ADS)

    Wu, Xiaoru; Gao, Yingyu; Ban, Chunlan; Huang, Qiang

    2016-09-01

    In this paper the results of the vapor-liquid equilibria study at 100 kPa are presented for two binary systems: α-phenylethylamine(1) + toluene (2) and (α-phenylethylamine(1) + cyclohexane(2)). The binary VLE data of the two systems were correlated by the Wilson, NRTL, and UNIQUAC models. For each binary system the deviations between the results of the correlations and the experimental data have been calculated. For the both binary systems the average relative deviations in temperature for the three models were lower than 0.99%. The average absolute deviations in vapour phase composition (mole fractions) and in temperature T were lower than 0.0271 and 1.93 K, respectively. Thermodynamic consistency has been tested for all vapor-liquid equilibrium data by the Herrington method. The values calculated by Wilson and NRTL equations satisfied the thermodynamics consistency test for the both two systems, while the values calculated by UNIQUAC equation didn't.

  16. Allan deviation analysis of financial return series

    NASA Astrophysics Data System (ADS)

    Hernández-Pérez, R.

    2012-05-01

    We perform a scaling analysis for the return series of different financial assets applying the Allan deviation (ADEV), which is used in the time and frequency metrology to characterize quantitatively the stability of frequency standards since it has demonstrated to be a robust quantity to analyze fluctuations of non-stationary time series for different observation intervals. The data used are opening price daily series for assets from different markets during a time span of around ten years. We found that the ADEV results for the return series at short scales resemble those expected for an uncorrelated series, consistent with the efficient market hypothesis. On the other hand, the ADEV results for absolute return series for short scales (first one or two decades) decrease following approximately a scaling relation up to a point that is different for almost each asset, after which the ADEV deviates from scaling, which suggests that the presence of clustering, long-range dependence and non-stationarity signatures in the series drive the results for large observation intervals.

  17. Clipping affects flowering of California poppy at two growth stages

    Treesearch

    Raymond D. Ratliff; Richard L. Hubbard

    1975-01-01

    The effects of clipping California-poppy (Eschscholzia californica Cham.) at various growth stages on plant survival, flowering, herbage yield, and root production were studied at the San Joaquin Experimental Range, in central California. Plants were clipped once to a 2-cm stubble at one of six stages. Through the early reproductive stage, a single...

  18. [Clip Sheets from BOCES. Opportunities. Health. Careers. = Oportunidades. Salud. Una Camera En...

    ERIC Educational Resources Information Center

    State Univ. of New York, Geneseo. Coll. at Geneseo. Migrant Center.

    This collection of 83 clip sheets, or classroom handouts, was created to help U.S. migrants learn more about health, careers, and general "opportunities" including education programs. They are written in both English and Spanish and are presented in an easily understandable format. Health clip-sheet topics include the following: Abuse; AIDS;…

  19. The "Isms" of Art. Introduction to the 2001-2002 Clip and Save Art Prints.

    ERIC Educational Resources Information Center

    Hubbard, Guy

    2001-01-01

    Provides an introduction to the 2001-2002 Clip and Save Art Prints that will focus on ten art movements from the past 150 years. Includes information on three art movements, or "isms": Classicism, Romanticism, and Realism. Discusses the Clip and Save Art Print format and provides information on three artists. (CMK)

  20. Clipping Versus Coiling in the Management of Posterior Communicating Artery Aneurysms with Third Nerve Palsy: A Systematic Review and Meta-Analysis.

    PubMed

    Gaberel, Thomas; Borha, Alin; di Palma, Camille; Emery, Evelyne

    2016-03-01

    To compare surgical clipping with endovascular coiling in terms of recovery from oculomotor nerve palsy (ONP) in the management of posterior communicating artery (PCoA) aneurysms causing third nerve palsy. We conducted a systematic review of the literature and meta-analysis. The meta-analysis included 11 relevant studies involving 384 patients with third nerve palsy caused by PCoA aneurysms at baseline, of whom 257 (67.0%) were treated by clipping and 127 were treated by coiling (33.0%). Pooled odds ratios of the impact of clipping or coiling on complete ONP recovery, lack of ONP recovery, and procedure-related death were calculated. The overall complete ONP recovery rate was 42.5% in the coiling group compared with 83.6% in the clipping group. The increase in complete ONP recovery in the clipping group corresponds to an overall pooled Mantel-Haenszel odds ratio of 4.44 (95% confidence interval = 1.66-11.84). Subgroup analysis revealed a clear benefit of clipping over coiling in patients with ruptured aneurysms, but not in patients with unruptured aneurysms. No procedure-related deaths were reported by any of the 11 studies. Surgical clipping of PCoA aneurysms causing third nerve palsy achieves better ONP recovery than endovascular coiling; this could be particularly true in the case of ruptured aneurysms. In view of the purely observational data, statements about this effect should be made with great caution. A randomized trial would better address the therapeutic dilemma, but pending the results of such a trial, we recommend treating PCoA aneurysms causing ONP with surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Oculomotor nerve palsy by posterior communicating artery aneurysms: influence of surgical strategy on recovery.

    PubMed

    Güresir, Erdem; Schuss, Patrick; Seifert, Volker; Vatter, Hartmut

    2012-11-01

    Resolution of oculomotor nerve palsy (ONP) after clipping of posterior communicating artery (PCoA) aneurysms has been well documented. However, whether additional decompression of the oculomotor nerve via aneurysm sac dissection or resection is superior to pure aneurysm clipping is the subject of much debate. Therefore, the objective in the present investigation was to analyze the influence of surgical strategy--specifically, clipping with or without aneurysm dissection--on ONP resolution. Between June 1999 and December 2010, 18 consecutive patients with ruptured and unruptured PCoA aneurysms causing ONP were treated at the authors' institution. Oculomotor nerve palsy was evaluated on admission and at follow-up. The electronic database MEDLINE was searched for additional data in published studies of PCoA aneurysms causing ONP. Two reviewers independently extracted data. Overall, 8 studies from the literature review and 6 patients in the current series (121 PCoA aneurysms) met the study inclusion criteria. Ninety-four aneurysms were treated with simple aneurysm neck clipping and 27 with clipping plus aneurysm sac decompression. The surgical strategy, simple aneurysm neck clipping versus clipping plus oculomotor nerve decompression, had no effect on full ONP resolution on univariate (p = 0.5) and multivariate analyses. On multivariate analysis, patients with incomplete ONP at admission were more likely to have full resolution of the palsy than were those with complete ONP at admission (p = 0.03, OR = 4.2, 95% CI 1.1-16). Data in the present study indicated that ONP caused by PCoA aneurysms improves after clipping without and with oculomotor nerve decompression. The resolution of ONP is inversely associated with the initial severity of ONP.

  2. Early retreatment after surgical clipping of ruptured intracranial aneurysms.

    PubMed

    Ito, Yoshiro; Yamamoto, Tetsuya; Ikeda, Go; Tsuruta, Wataro; Uemura, Kazuya; Komatsu, Yoji; Matsumura, Akira

    2017-09-01

    Although a rerupture after surgical clipping of ruptured intracranial aneurysms is rare, it is associated with high morbidity and mortality. The causes for retreatment and rupture after surgical clipping are not clearly defined. From a prospectively maintained database of 244 patients who had undergone surgical clipping of ruptured intracranial aneurysms, we selected patients who experienced retreatment or rerupture within 30 days after surgical clipping. Aneurysm occlusions were examined by microvascular Doppler ultrasonography and indocyanine green video-angiography. Indications for retreatment included rerupture and partial occlusion. We analyzed the characteristics and causes of early retreatment. Six patients (2.5%, 95% CI 0.9 to 5.3%) were retreated within 30 days after surgical clipping, including two patients (0.8%, 95% CI 0.1 to 2.9%) who experienced a rerupture. The retreated aneurysms were found in the anterior communicating artery (AcomA) (n = 5) and basilar artery (n = 1). Retreatment of the AcomA (7.5%) was performed significantly more frequently than that of other arteries (0.56%) (p < 0.01). A laterally projected AcomA aneurysm (17.4%) was more frequently retreated than were other aneurysm types (2.3%). Cases of laterally projecting AcomA aneurysms tended to result from an incomplete clip placed using a pterional approach from the opposite side of the aneurysm projection. Despite developments, the rates of retreatment and rerupture after surgical clipping remain similar to those reported previously. Retreatment of the AcomA was significantly more frequent than was retreatment of other arteries. Patients underwent retreatment more frequently when they were originally treated for lateral type aneurysms using a pterional approach from the opposite side of the aneurysm projection. The treatment method and evaluation modalities should be considered carefully for AcomA aneurysms in particular.

  3. Epicardial clip occlusion of the left atrial appendage during cardiac surgery provides optimal surgical results and long-term stability.

    PubMed

    Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr

    2017-07-01

    Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Impact of metal artifact reduction software on image quality of gemstone spectral imaging dual-energy cerebral CT angiography after intracranial aneurysm clipping.

    PubMed

    Dunet, Vincent; Bernasconi, Martine; Hajdu, Steven David; Meuli, Reto Antoine; Daniel, Roy Thomas; Zerlauth, Jean-Baptiste

    2017-09-01

    We aimed to assess the impact of metal artifact reduction software (MARs) on image quality of gemstone spectral imaging (GSI) dual-energy (DE) cerebral CT angiography (CTA) after intracranial aneurysm clipping. This retrospective study was approved by the institutional review board, which waived patient written consent. From January 2013 to September 2016, single source DE cerebral CTA were performed in 45 patients (mean age: 60 ± 9 years, male 9) after intracranial aneurysm clipping and reconstructed with and without MARs. Signal-to-noise (SNR), contrast-to-noise (CNR), and relative CNR (rCNR) ratios were calculated from attenuation values measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Volume of clip and artifacts and relative clip blurring reduction (rCBR) ratios were also measured at each energy level with/without MARs. Variables were compared between GSI and GSI-MARs using the paired Wilcoxon signed-rank test. MARs significantly reduced metal artifacts at all energy levels but 130 and 140 keV, regardless of clips' location and number. The optimal rCBR was obtained at 110 and 80 keV, respectively, on GSI and GSI-MARs images, with up to 96% rCNR increase on GSI-MARs images. The best compromise between metal artifact reduction and rCNR was obtained at 70-75 and 65-70 keV for GSI and GSI-MARs images, respectively, with up to 15% rCBR and rCNR increase on GSI-MARs images. MARs significantly reduces metal artifacts on DE cerebral CTA after intracranial aneurysm clipping regardless of clips' location and number. It may be used to reduce radiation dose while increasing CNR.

  5. Fabrication and Characterization of ZnO Nano-Clips by the Polyol-Mediated Process.

    PubMed

    Wang, Mei; Li, Ai-Dong; Kong, Ji-Zhou; Gong, You-Pin; Zhao, Chao; Tang, Yue-Feng; Wu, Di

    2018-02-09

    ZnO nano-clips with better monodispersion were prepared successfully using zinc acetate hydrate (Zn(OAc) 2 ·nH 2 O) as Zn source and ethylene glycol (EG) as solvent by a simple solution-based route-polyol process. The effect of solution concentration on the formation of ZnO nano-clips has been investigated deeply. We first prove that the 0.01 M Zn(OAc) 2 ·nH 2 O can react with EG without added water or alkaline, producing ZnO nano-clips with polycrystalline wurtzite structure at 170 °C. As-synthesized ZnO nano-clips contain a lot of aggregated nanocrystals (~ 5 to 15 nm) with high specific surface area of 88 m 2 /g. The shapes of ZnO nano-clips basically keep constant with improved crystallinity after annealing at 400-600 °C. The lower solution concentration and slight amount of H 2 O play a decisive role in ZnO nano-clip formation. When the solution concentration is ≤ 0.0125 M, the complexing and polymerization reactions between Zn(OAc) 2 ·nH 2 O and EG predominate, mainly elaborating ZnO nano-clips. When the solution concentration is ≥ 0.015 M, the alcoholysis and polycondensation reactions of Zn(OAc) 2 ·nH 2 O and EG become dominant, leading to ZnO particle formation with spherical and elliptical shapes. The possible growth mechanism based on a competition between complexing and alcoholysis of Zn(OAc) 2 ·nH 2 O and EG has been proposed.

  6. Simulation and Analysis of Topographic Effect on Land Surface Albedo over Mountainous Areas

    NASA Astrophysics Data System (ADS)

    Hao, D.; Wen, J.; Xiao, Q.

    2017-12-01

    Land surface albedo is one of the significant geophysical variables affecting the Earth's climate and controlling the surface radiation budget. Topography leads to the formation of shadows and the redistribution of incident radiation, which complicates the modeling and estimation of the land surface albedo. Some studies show that neglecting the topography effect may lead to significant bias in estimating the land surface albedo for the sloping terrain. However, for the composite sloping terrain, the topographic effects on the albedo remain unclear. Accurately estimating the sub-topographic effect on the land surface albedo over the composite sloping terrain presents a challenge for remote sensing modeling and applications. In our study, we focus on the development of a simplified estimation method for land surface albedo including black-sky albedo (BSA) and white-sky albedo (WSA) of the composite sloping terrain at a kilometer scale based on the fine scale DEM (30m) and quantitatively investigate and understand the topographic effects on the albedo. The albedo is affected by various factors such as solar zenith angle (SZA), solar azimuth angle (SAA), shadows, terrain occlusion, and slope and aspect distribution of the micro-slopes. When SZA is 30°, the absolute and relative deviations between the BSA of flat terrain and that of rugged terrain reaches 0.12 and 50%, respectively. When the mean slope of the terrain is 30.63° and SZA=30°, the absolute deviation of BSA caused by SAA can reach 0.04. The maximal relative and relative deviation between the WSA of flat terrain and that of rugged terrain reaches 0.08 and 50%. These results demonstrate that the topographic effect has to be taken into account in the albedo estimation.

  7. HITS-CLIP yields genome-wide insights into brain alternative RNA processing

    NASA Astrophysics Data System (ADS)

    Licatalosi, Donny D.; Mele, Aldo; Fak, John J.; Ule, Jernej; Kayikci, Melis; Chi, Sung Wook; Clark, Tyson A.; Schweitzer, Anthony C.; Blume, John E.; Wang, Xuning; Darnell, Jennifer C.; Darnell, Robert B.

    2008-11-01

    Protein-RNA interactions have critical roles in all aspects of gene expression. However, applying biochemical methods to understand such interactions in living tissues has been challenging. Here we develop a genome-wide means of mapping protein-RNA binding sites in vivo, by high-throughput sequencing of RNA isolated by crosslinking immunoprecipitation (HITS-CLIP). HITS-CLIP analysis of the neuron-specific splicing factor Nova revealed extremely reproducible RNA-binding maps in multiple mouse brains. These maps provide genome-wide in vivo biochemical footprints confirming the previous prediction that the position of Nova binding determines the outcome of alternative splicing; moreover, they are sufficiently powerful to predict Nova action de novo. HITS-CLIP revealed a large number of Nova-RNA interactions in 3' untranslated regions, leading to the discovery that Nova regulates alternative polyadenylation in the brain. HITS-CLIP, therefore, provides a robust, unbiased means to identify functional protein-RNA interactions in vivo.

  8. Eliciting positive, negative and mixed emotional states: A film library for affective scientists.

    PubMed

    Samson, Andrea C; Kreibig, Sylvia D; Soderstrom, Blake; Wade, A Ayanna; Gross, James J

    2016-08-01

    We describe the creation of a film library designed for researchers interested in positive (amusing), negative (repulsive), mixed (amusing and repulsive) and neutral emotional states. Three hundred 20- to 33-second film clips videotaped by amateurs were selected from video-hosting websites and screened in laboratory studies by 75 female participants on self-reported amusement and repulsion (Experiments 1 and 2). On the basis of pre-defined cut-off values, 51 positive, 39 negative, 59 mixed and 50 neutral film clips were selected. These film clips were then presented to 411 male and female participants in a large online study to identify film clips that reliably induced the target emotions (Experiment 3). Depending on the goal of the study, researchers may choose positive, negative, mixed or neutral emotional film clips on the basis of Experiments 1 and 2 or Experiment 3 ratings.

  9. Embedded CLIPS for SDI BM/C3 simulation and analysis

    NASA Technical Reports Server (NTRS)

    Gossage, Brett; Nanney, Van

    1990-01-01

    Nichols Research Corporation is developing the BM/C3 Requirements Analysis Tool (BRAT) for the U.S. Army Strategic Defense Command. BRAT uses embedded CLIPS/Ada to model the decision making processes used by the human commander of a defense system. Embedding CLlPS/Ada in BRAT allows the user to explore the role of the human in Command and Control (C2) and the use of expert systems for automated C2. BRAT models assert facts about the current state of the system, the simulated scenario, and threat information into CLIPS/Ada. A user-defined rule set describes the decision criteria for the commander. We have extended CLIPS/Ada with user-defined functions that allow the firing of a rule to invoke a system action such as weapons release or a change in strategy. The use of embedded CLIPS/Ada will provide a powerful modeling tool for our customer at minimal cost.

  10. Using PVM to host CLIPS in distributed environments

    NASA Technical Reports Server (NTRS)

    Myers, Leonard; Pohl, Kym

    1994-01-01

    It is relatively easy to enhance CLIPS (C Language Integrated Production System) to support multiple expert systems running in a distributed environment with heterogeneous machines. The task is minimized by using the PVM (Parallel Virtual Machine) code from Oak Ridge Labs to provide the distributed utility. PVM is a library of C and FORTRAN subprograms that supports distributive computing on many different UNIX platforms. A PVM deamon is easily installed on each CPU that enters the virtual machine environment. Any user with rsh or rexec access to a machine can use the one PVM deamon to obtain a generous set of distributed facilities. The ready availability of both CLIPS and PVM makes the combination of software particularly attractive for budget conscious experimentation of heterogeneous distributive computing with multiple CLIPS executables. This paper presents a design that is sufficient to provide essential message passing functions in CLIPS and enable the full range of PVM facilities.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedman-Hill, Ernest

    Java Expert Shell System - Jess - is a rule engine and scripting environment written entirely in Sun's Java language, Jess was orginially inspired by the CLIPS expert system shell, but has grown int a complete, distinct JAVA-influenced environment of its own. Using Jess, you can build Java applets and applications that have the capacity to "reason" using knowledge you supply in the form of declarative rules. Jess is surprisingly fast, and for some problems is faster than CLIPS, in that many Jess scripts are valid CLIPS scripts and vice-versa. Like CLIPS, Jess uses the Rete algorithm to process rules,more » a very efficient mechanism for solving the difficult many-to-many matching problem. Jess adds many features to CLIPS, including backwards chaining and the ability to manipulate and directly reason about Java objects. Jess is also a powerful Java scripting environment, from which you can create Java objects and call Java methods without compiling any Java Code.« less

  12. Integrating CLIPS applications into heterogeneous distributed systems

    NASA Technical Reports Server (NTRS)

    Adler, Richard M.

    1991-01-01

    SOCIAL is an advanced, object-oriented development tool for integrating intelligent and conventional applications across heterogeneous hardware and software platforms. SOCIAL defines a family of 'wrapper' objects called agents, which incorporate predefined capabilities for distributed communication and control. Developers embed applications within agents and establish interactions between distributed agents via non-intrusive message-based interfaces. This paper describes a predefined SOCIAL agent that is specialized for integrating C Language Integrated Production System (CLIPS)-based applications. The agent's high-level Application Programming Interface supports bidirectional flow of data, knowledge, and commands to other agents, enabling CLIPS applications to initiate interactions autonomously, and respond to requests and results from heterogeneous remote systems. The design and operation of CLIPS agents are illustrated with two distributed applications that integrate CLIPS-based expert systems with other intelligent systems for isolating and mapping problems in the Space Shuttle Launch Processing System at the NASA Kennedy Space Center.

  13. Gödel, Tarski, Turing and the Conundrum of Free Will

    NASA Astrophysics Data System (ADS)

    Nayakar, Chetan S. Mandayam; Srikanth, R.

    2014-07-01

    The problem of defining and locating free will (FW) in physics is studied. On the basis of logical paradoxes, we argue that FW has a metatheoretic character, like the concept of truth in Tarski's undefinability theorem. Free will exists relative to a base theory if there is freedom to deviate from the deterministic or indeterministic dynamics in the theory, with the deviations caused by parameters (representing will) in the meta-theory. By contrast, determinism and indeterminism do not require meta-theoretic considerations in their formalization, making FW a fundamentally new causal primitive. FW exists relative to the meta-theory if there is freedom for deviation, due to higher-order causes. Absolute free will, which corresponds to our intuitive introspective notion of free will, exists if this meta-theoretic hierarchy is infinite. We argue that this hierarchy corresponds to higher levels of uncomputability. In other words, at any finitely high order in the hierarchy, there are uncomputable deviations from the law at that order. Applied to the human condition, the hierarchy corresponds to deeper levels of the subconscious or unconscious mind. Possible ramifications of our model for physics, neuroscience and artificial intelligence (AI) are briefly considered.

  14. Decomposition Analyses Applied to a Complex Ultradian Biorhythm: The Oscillating NADH Oxidase Activity of Plasma Membranes Having a Potential Time-Keeping (Clock) Function

    PubMed Central

    Foster, Ken; Anwar, Nasim; Pogue, Rhea; Morré, Dorothy M.; Keenan, T. W.; Morré, D. James

    2003-01-01

    Seasonal decomposition analyses were applied to the statistical evaluation of an oscillating activity for a plasma membrane NADH oxidase activity with a temperature compensated period of 24 min. The decomposition fits were used to validate the cyclic oscillatory pattern. Three measured values, average percentage error (MAPE), a measure of the periodic oscillation, mean average deviation (MAD), a measure of the absolute average deviations from the fitted values, and mean standard deviation (MSD), the measure of standard deviation from the fitted values plus R-squared and the Henriksson-Merton p value were used to evaluate accuracy. Decomposition was carried out by fitting a trend line to the data, then detrending the data if necessary, by subtracting the trend component. The data, with or without detrending, were then smoothed by subtracting a centered moving average of length equal to the period length determined by Fourier analysis. Finally, the time series were decomposed into cyclic and error components. The findings not only validate the periodic nature of the major oscillations but suggest, as well, that the minor intervening fluctuations also recur within each period with a reproducible pattern of recurrence. PMID:19330112

  15. The Nightingale study: rationale, study design and baseline characteristics of a prospective cohort study on shift work and breast cancer risk among nurses.

    PubMed

    Pijpe, Anouk; Slottje, Pauline; van Pelt, Cres; Stehmann, Floor; Kromhout, Hans; van Leeuwen, Flora E; Vermeulen, Roel C H; Rookus, Matti A

    2014-01-29

    Evidence for the carcinogenicity of shift work in humans is limited because of significant heterogeneity of the results, thus more in-depth research in needed. The Nightingale Study is a nationwide prospective cohort study on occupational exposures and risks of chronic diseases among female nurses and focuses on the potential association between shift work and risk of breast cancer. The study design, methods, and baseline characteristics of the cohort are described. The source population for the cohort comprised 18 to 65 year old women who were registered as having completed training to be a nurse in the nationwide register for healthcare professionals in the Netherlands. Eligible women were invited to complete a web-based questionnaire including full job history, a detailed section on all domains of shift work (shift system, cumulative exposure, and shift intensity) and potential confounding factors, and an informed consent form for linkage with national (disease) registries. Women were also asked to donate toenail clippings as a source of DNA for genetic analyses. Between October 6, 2011 and February 1, 2012, 31% of the 192,931 women who were invited to participate completed the questionnaire, yielding a sample size of 59,947 cohort members. The mean age of the participants was 46.9 year (standard deviation 11.0 years). Toenail clippings were provided by 23,439 participants (39%). Results from the Nightingale Study will contribute to the scientific evidence of potential shift work-related health risks among nurses and will help develop preventive measures and policy aimed at reducing these risks.

  16. What's Eating Gilbert Grape?: A Case Study of Chronic Illness

    ERIC Educational Resources Information Center

    Alexander, Matthew; Waxman, Dael; White, Patricia

    2006-01-01

    Cinemeducation refers to the use of movies or movie clips to educate learners about the psychosocial aspects of health care. This paper describes the use of a clip from the movie, "What's Eating Gilbert Grape?" to teach medical students about chronic illness. The clip is used to set up a case study based on the lead character, Gilbert…

  17. First CLIPS Conference Proceedings, volume 1

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The first Conference of C Language Production Systems (CLIPS) hosted by the NASA-Lyndon B. Johnson Space Center in August 1990 is presented. Articles included engineering applications, intelligent tutors and training, intelligent software engineering, automated knowledge acquisition, network applications, verification and validation, enhancements to CLIPS, space shuttle quality control/diagnosis applications, space shuttle and real-time applications, and medical, biological, and agricultural applications.

  18. Using Film Clips to Teach Teen Pregnancy Prevention: "The Gloucester 18" at a Teen Summit

    ERIC Educational Resources Information Center

    Herrman, Judith W.; Moore, Christopher C.; Anthony, Becky

    2012-01-01

    Teaching pregnancy prevention to large groups offers many challenges. This article describes the use of film clips, with guided discussion, to teach pregnancy prevention. In order to analyze the costs associated with teen pregnancy, a film clip discussion session based with the film "The Gloucester 18" was the keynote of a youth summit. The lesson…

  19. C Language Integrated Production System, Ada Version

    NASA Technical Reports Server (NTRS)

    Culbert, Chris; Riley, Gary; Savely, Robert T.; Melebeck, Clovis J.; White, Wesley A.; Mcgregor, Terry L.; Ferguson, Melisa; Razavipour, Reza

    1992-01-01

    CLIPS/Ada provides capabilities of CLIPS v4.3 but uses Ada as source language for CLIPS executable code. Implements forward-chaining rule-based language. Program contains inference engine and language syntax providing framework for construction of expert-system program. Also includes features for debugging application program. Based on Rete algorithm which provides efficient method for performing repeated matching of patterns. Written in Ada.

  20. Blowout Monitor

    NASA Technical Reports Server (NTRS)

    1994-01-01

    C Language Integrated Production System (CLIPS), a NASA-developed software shell for developing expert systems, has been embedded in a PC-based expert system for training oil rig personnel in monitoring oil drilling. Oil drilling rigs if not properly maintained for possible blowouts pose hazards to human life, property and the environment may be destroyed. CLIPS is designed to permit the delivery of artificial intelligence on computer. A collection of rules is set up and, as facts become known, these rules are applied. In the Well Site Advisor, CLIPS provides the capability to accurately process, predict and interpret well data in a real time mode. CLIPS was provided to INTEQ by COSMIC.

  1. PCLIPS

    NASA Technical Reports Server (NTRS)

    Krolak, Patrick D.

    1990-01-01

    CLIPS is an expert system, created specifically to allow rapid implementation of an expert system. CLIPS is written in C, and thus needs a very small amount of memory to run. Parallel CLIPS (PCLIPS) is an extension to CLIPS which is intended to be used in situations where a group of expert systems are expected to run simultaneously and occasionally communicate with each other on an integrated network. PCLIPS is a coarse-grained data distribution system. Its main goal is to take information in one knowledge base and distribute it to other knowledge bases so that all the executing expert systems are able to use that knowledge to solve their disparate problems.

  2. Microleakage of different temporary filling materials in primary teeth.

    PubMed

    Odabas, Mesut Enes; Tulunoglu, Ozlem; Ozalp, Serife Ozdemir; Bodur, Haluk

    2009-01-01

    The aim of this study was to compare the sealing properties of IRM, Coltosol, Cavit G, Adhesor and Clip, which used as temporary filling material in coronal access openings in extracted human primary teeth. Standardized access cavities of 2 x 2 mm were prepared in the eighty-four, caries-free human primary anterior teeth. The teeth were divided randomly into five groups of 16 teeth each. Temporary restorative materials Group A: IRM (Dentsply), Group B: Coltosol (Coltone), Group C: Cavit G (3M), Group D: Adhesor (Spofa Dental) and Group E: Clip (Voco) were applied according to the manufacturer's directions. The specimens were immersed silver nitrate and placed in film developer under fluorescent for 24 hours. The sectioned specimens were evaluated under a digital microscope at x 20 magnifications and blindly scored for microleakage. Clip presented the least microleakage value whereas; Adhesor and IRM presented the higher microleakage values. There were statistically significant differences between Clip and the others groups, while there were no statistically significant differences in microleakage between IRM, Adhesor, Coltosol and Cavit G. However the leakage scores of Clip and Cavit G were congruent (p = 0.454). Amongst the five materials, Clip exhibited a better sealing ability.

  3. Rumen fluid fermentation for enhancement of hydrolysis and acidification of grass clipping.

    PubMed

    Wang, Siqi; Zhang, Guangming; Zhang, Panyue; Ma, Xiaowen; Li, Fan; Zhang, Haibo; Tao, Xue; Ye, Junpei; Nabi, Mohammad

    2018-08-15

    Rumen fluid, formed in rumen of ruminants, includes a complex microbial population of bacteria, protozoa, fungi and archaea, and has high ability to degrade lignocellulosic biomass. In this study, rumen fluid was used to ferment grass clipping for enhancing the hydrolysis and acidification of organic matters. Results showed that strict anaerobic condition, higher grass clipping content and smaller particle size of grass clipping were beneficial to the hydrolysis and acidification of organics. The increase of SCOD and total VFA concentration respectively reached 24.9 and 10.2 g/L with a suitable grass clipping content of 5%, a particle size <0.150 mm, and a fermentation time of 48 h. The VFA production was mainly attributed to the degradation of cellulose and hemicellulose with a total solid reduction of 55.7%. Firmicutes and Fibrobacteres were the major contributors to the degradation of cellulose and hemicellulose. The activity of carboxymethyl cellulose enzyme (CMCase), cellobiase and xylanase reached 0.027, 0.176 and 0.180 U/ml, respectively. The rumen fluid microorganisms successfully enhanced the hydrolysis and acidification of grass clipping. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Responses to water depth and clipping of twenty−three plant species in an Indian monsoonal wetland

    USGS Publications Warehouse

    Middleton, Beth A.; van der Valk, Arnold; Davis, Craig B.

    2015-01-01

    Responses of species to disturbances give insights into how species might respond to future wetland changes. In this study, species of monsoonal wetlands belonging to various functional types (graminoid and non−graminoid emergents, submersed aquatic, floating−leaved aquatic) varied in their growth responses to water depth and harvesting. We tested the effects of water depth (moist soil, flooded) and clipping (unclipped, and clipped) on the biomass and longevity of twenty−three dominant plant species of monsoonal wetlands in the Keoladeo National Park, India in a controlled experiment. With respect to total biomass and survival, six species responded positively to flooding and twelve species responded negatively to clipping. Responses to flooding and clipping, however, sometimes interacted. Individualistic responses of species to water levels and clipping regimes were apparent; species within a functional group did not always respond similarly. Therefore, detailed information on the individualistic responses of species may be needed to predict the vegetation composition of post−disturbance wetlands. In particular, as demands for fresh water increase around the world, studies of life history constraints and responses to hydrological changes will aid wetland managers in developing strategies to conserve biodiversity.

  5. Process development for high-resolution 3D-printing of bioresorbable vascular stents

    NASA Astrophysics Data System (ADS)

    Ware, Henry Oliver T.; Farsheed, Adam C.; van Lith, Robert; Baker, Evan; Ameer, Guillermo; Sun, Cheng

    2017-02-01

    The recent development of "continuous projection microstereolithography" also known as CLIP technology has successfully alleviated the main obstacles surrounding 3D printing technologies: production speed and part quality. Following the same working principle, we further developed the μCLIP process to address the needs for high-resolution 3D printing of biomedical devices with micron-scale precision. Compared to standard stereolithography (SLA) process, μCLIP fabrication can reduce fabrication time from several hours to as little as a few minutes. μCLIP can also produce better surface finish and more uniform mechanical properties than conventional SLA, as each individual "fabrication layer" continuously polymerizes into the subsequent layer. In this study, we report the process development in manufacturing high-resolution bioresorbable stents using our own μCLIP system. The bioresorbable photopolymerizable biomaterial (B-ink) used in this study is methacrylated poly(1, 12 dodecamethylene citrate) (mPDC). Through optimization of our μCLIP process and concentration of B-ink components, we have created a customizable bioresorbable stent with similar mechanical properties exhibited by nitinol stents. Upon optimization, fabricating a 2 cm tall vascular stent that comprises 4000 layers was accomplished in 26.5 minutes.

  6. Effects of orally administered lavender essential oil on responses to anxiety-provoking film clips.

    PubMed

    Bradley, Belinda F; Brown, Stephen L; Chu, Simon; Lea, Robert W

    2009-06-01

    Lavender odour is commonly used to alleviate mild anxiety. Double blind studies are difficult to conduct with odours, and there are few reliable investigations of lavender's efficacy. Orally administered lavender capsules (placebo, 100, 200 microl) were tested in a randomised between-subjects (n = 97) double-blind study. Film clips were used to elicit anxiety. Measures included anxiety, State Trait Anxiety Inventory (STAI), mood, positive and negative affect scale (PANAS), heart rate (HR), galvanic skin response (GSR), and heart rate variation (HRV). Following baseline measurements capsules were administered. Participants viewed a neutral film clip, then an anxiety-provoking and light-hearted recovery film clip. For the 200 microl lavender dose during the neutral film clip there was a trend towards reduced state anxiety, GSR and HR and increased HRV. In the anxiety-eliciting film, lavender was mildly beneficial in females but only on HRV measures. In males sympathetic arousal increased during the anxiety film (GSR). HRV significantly increased at 200 microl during all three film clips in females, suggesting decreased anxiety. These findings suggest that lavender has anxiolytic effects in humans under conditions of low anxiety, but these effects may not extend to conditions of high anxiety.

  7. Alleviating travel anxiety through virtual reality and narrated video technology.

    PubMed

    Ahn, J C; Lee, O

    2013-01-01

    This study presents an empirical evidence of benefit of narrative video clips in embedded virtual reality websites of hotels for relieving travel anxiety. Even though it was proven that virtual reality functions do provide some relief in travel anxiety, a stronger virtual reality website can be built when narrative video clips that show video clips with narration about important aspects of the hotel. We posit that these important aspects are 1. Escape route and 2. Surrounding neighborhood information, which are derived from the existing research on anxiety disorder as well as travel anxiety. Thus we created a video clip that showed and narrated about the escape route from the hotel room, another video clip that showed and narrated about surrounding neighborhood. We then conducted experiments with this enhanced virtual reality website of a hotel by having human subjects play with the website and fill out a questionnaire. The result confirms our hypothesis that there is a statistically significant relationship between the degree of travel anxiety and psychological relief caused by the use of embedded virtual reality functions with narrative video clips of a hotel website (Tab. 2, Fig. 3, Ref. 26).

  8. Teaching professionalism to first year medical students using video clips.

    PubMed

    Shevell, Allison Haley; Thomas, Aliki; Fuks, Abraham

    2015-01-01

    Medical schools are confronted with the challenge of teaching professionalism during medical training. The aim of this study was to examine medical students' perceptions of using video clips as a beneficial teaching tool to learn professionalism and other aspects of physicianship. As part of the longitudinal Physician Apprenticeship course at McGill University, first year medical students viewed video clips from the television series ER. The study used qualitative description and thematic analysis to interpret responses to questionnaires, which explored the educational merits of this exercise. Completed questionnaires were submitted by 112 students from 21 small groups. A major theme concerned the students' perceptions of the utility of video clips as a teaching tool, and consisted of comments organized into 10 categories: "authenticity and believability", "thought provoking", "skills and approaches", "setting", "medium", "level of training", "mentorship", "experiential learning", "effectiveness" and "relevance to practice". Another major theme reflected the qualities of physicianship portrayed in video clips, and included seven categories: "patient-centeredness", "communication", "physician-patient relationship", "professionalism", "ethical behavior", "interprofessional practice" and "mentorship". This study demonstrated that students perceived the value of using video clips from a television series as a means of teaching professionalism and other aspects of physicianship.

  9. Results of the first North American comparison of absolute gravimeters, NACAG-2010

    USGS Publications Warehouse

    Schmerge, David; Francis, Olvier; Henton, J.; Ingles, D.; Jones, D.; Kennedy, Jeffrey R.; Krauterbluth, K.; Liard, J.; Newell, D.; Sands, R.; Schiel, J.; Silliker, J.; van Westrum, D.

    2012-01-01

    The first North American Comparison of absolute gravimeters (NACAG-2010) was hosted by the National Oceanic and Atmospheric Administration at its newly renovated Table Mountain Geophysical Observatory (TMGO) north of Boulder, Colorado, in October 2010. NACAG-2010 and the renovation of TMGO are part of NGS’s GRAV-D project (Gravity for the Redefinition of the American Vertical Datum). Nine absolute gravimeters from three countries participated in the comparison. Before the comparison, the gravimeter operators agreed to a protocol describing the strategy to measure, calculate, and present the results. Nine sites were used to measure the free-fall acceleration of g. Each gravimeter measured the value of g at a subset of three of the sites, for a total set of 27 g-values for the comparison. The absolute gravimeters agree with one another with a standard deviation of 1.6 µGal (1 Gal = 1 cm s-2). The minimum and maximum offsets are -2.8 and 2.7 µGal. This is an excellent agreement and can be attributed to multiple factors, including gravimeters that were in good working order, good operators, a quiet observatory, and a short duration time for the experiment. These results can be used to standardize gravity surveys internationally.

  10. Effect of helicity on the correlation time of large scales in turbulent flows

    NASA Astrophysics Data System (ADS)

    Cameron, Alexandre; Alexakis, Alexandros; Brachet, Marc-Étienne

    2017-11-01

    Solutions of the forced Navier-Stokes equation have been conjectured to thermalize at scales larger than the forcing scale, similar to an absolute equilibrium obtained for the spectrally truncated Euler equation. Using direct numeric simulations of Taylor-Green flows and general-periodic helical flows, we present results on the probability density function, energy spectrum, autocorrelation function, and correlation time that compare the two systems. In the case of highly helical flows, we derive an analytic expression describing the correlation time for the absolute equilibrium of helical flows that is different from the E-1 /2k-1 scaling law of weakly helical flows. This model predicts a new helicity-based scaling law for the correlation time as τ (k ) ˜H-1 /2k-1 /2 . This scaling law is verified in simulations of the truncated Euler equation. In simulations of the Navier-Stokes equations the large-scale modes of forced Taylor-Green symmetric flows (with zero total helicity and large separation of scales) follow the same properties as absolute equilibrium including a τ (k ) ˜E-1 /2k-1 scaling for the correlation time. General-periodic helical flows also show similarities between the two systems; however, the largest scales of the forced flows deviate from the absolute equilibrium solutions.

  11. Impact of Aneurysm Projection on Intraoperative Complications During Surgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    PubMed

    Fukuda, Hitoshi; Hayashi, Kosuke; Yoshino, Kumiko; Koyama, Takashi; Lo, Benjamin; Kurosaki, Yoshitaka; Yamagata, Sen

    2016-03-01

    Surgical clipping of ruptured posterior communicating artery (PCoA) aneurysms is a well-established procedure to date. However, preoperative factors associated with procedure-related risk require further elucidation. To investigate the impact of the direction of aneurysm projection on the incidence of procedure-related complications during surgical clipping of ruptured PCoA aneurysms. A total of 65 patients with ruptured PCoA aneurysms who underwent surgical clipping were retrospectively analyzed from a single-center, prospective, observational cohort database in this study. The aneurysms were categorized into lateral and posterior projection groups, depending on direction of the dome. Characteristics and operative findings of each projection group were identified. We also evaluated any correlation of aneurysm projection with the incidence of procedure-related complications. Patients with ruptured PCoA aneurysms with posterior projection more likely presented with good-admission-grade subarachnoid hemorrhage (P = .01, χ test) and were less to also have intracerebral hematoma (P = .01). These aneurysms were found to be associated with higher incidence of intraoperative rupture (P = .02), complex clipping with fenestrated clips (P = .02), and dense adherence to PCoA or its perforators (P = .04) by univariate analysis. Aneurysms with posterior projection were also correlated with procedure-related complications, including postoperative cerebral infarction or hematoma formation (odds ratio, 5.87; 95% confidence interval, 1.11-31.1; P = .04) by multivariable analysis. Ruptured PCoA aneurysms with posterior projection carried a higher risk of procedure-related complications of surgical clipping than those with lateral projection.

  12. Microsurgery Simulator of Cerebral Aneurysm Clipping with Interactive Cerebral Deformation Featuring a Virtual Arachnoid.

    PubMed

    Shono, Naoyuki; Kin, Taichi; Nomura, Seiji; Miyawaki, Satoru; Saito, Toki; Imai, Hideaki; Nakatomi, Hirofumi; Oyama, Hiroshi; Saito, Nobuhito

    2018-05-01

    A virtual reality simulator for aneurysmal clipping surgery is an attractive research target for neurosurgeons. Brain deformation is one of the most important functionalities necessary for an accurate clipping simulator and is vastly affected by the status of the supporting tissue, such as the arachnoid membrane. However, no virtual reality simulator implementing the supporting tissue of the brain has yet been developed. To develop a virtual reality clipping simulator possessing interactive brain deforming capability closely dependent on arachnoid dissection and apply it to clinical cases. Three-dimensional computer graphics models of cerebral tissue and surrounding structures were extracted from medical images. We developed a new method for modifiable cerebral tissue complex deformation by incorporating a nonmedical image-derived virtual arachnoid/trabecula in a process called multitissue integrated interactive deformation (MTIID). MTIID made it possible for cerebral tissue complexes to selectively deform at the site of dissection. Simulations for 8 cases of actual clipping surgery were performed before surgery and evaluated for their usefulness in surgical approach planning. Preoperatively, each operative field was precisely reproduced and visualized with the virtual brain retraction defined by users. The clear visualization of the optimal approach to treating the aneurysm via an appropriate arachnoid incision was possible with MTIID. A virtual clipping simulator mainly focusing on supporting tissues and less on physical properties seemed to be useful in the surgical simulation of cerebral aneurysm clipping. To our knowledge, this article is the first to report brain deformation based on supporting tissues.

  13. The effect of music video clips on adolescent boys' body image, mood, and schema activation.

    PubMed

    Mulgrew, Kate E; Volcevski-Kostas, Diana; Rendell, Peter G

    2014-01-01

    There is limited research that has examined experimentally the effects of muscular images on adolescent boys' body image, with no research specifically examining the effects of music television. The aim of the current study was to examine the effects of viewing muscular and attractive singers in music video clips on early, mid, and late adolescent boys' body image, mood, and schema activation. Participants were 180 boys in grade 7 (mean age = 12.73 years), grade 9 (mean age = 14.40 years) or grade 11 (mean age = 16.15 years) who completed pre- and post-test measures of mood and body satisfaction after viewing music videos containing male singers of muscular or average appearance. They also completed measures of schema activation and social comparison after viewing the clips. The results showed that the boys who viewed the muscular clips reported poorer upper body satisfaction, lower appearance satisfaction, lower happiness, and more depressive feelings compared to boys who viewed the clips depicting singers of average appearance. There was no evidence of increased appearance schema activation but the boys who viewed the muscular clips did report higher levels of social comparison to the singers. The results suggest that music video clips are a powerful form of media in conveying information about the male ideal body shape and that negative effects are found in boys as young as 12 years.

  14. A film set for the elicitation of emotion in research: A comprehensive catalog derived from four decades of investigation.

    PubMed

    Gilman, T Lee; Shaheen, Razan; Nylocks, K Maria; Halachoff, Danielle; Chapman, Jessica; Flynn, Jessica J; Matt, Lindsey M; Coifman, Karin G

    2017-12-01

    Emotions are highly influential to many psychological processes. Indeed, research employing emotional stimuli is rapidly escalating across the field of psychology. However, challenges remain regarding discrete evocation of frequently co-elicited emotions such as amusement and happiness, or anger and disgust. Further, as much contemporary work in emotion employs college students, we sought to additionally evaluate the efficacy of film clips to discretely elicit these more challenging emotions in a young adult population using an online medium. The internet is an important tool for investigating responses to emotional stimuli, but validations of emotionally evocative film clips across laboratory and web-based settings are limited in the literature. An additional obstacle is identifying stimuli amidst the numerous film clip validation studies. During our investigation, we recognized the lack of a categorical database to facilitate rapid identification of useful film clips for individual researchers' unique investigations. Consequently, here we also sought to produce the first compilation of such stimuli into an accessible and comprehensive catalog. We based our catalog upon prior work as well as our own, and identified 24 articles and 295 film clips from four decades of research. We present information on the validation of these clips in addition to our own research validating six clips using online administration settings. The results of our search in the literature and our own study are presented in tables designed to facilitate and improve a selection of highly valid film stimuli for future research.

  15. 40 CFR 1065.1005 - Symbols, abbreviations, acronyms, and units of measure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... least squares regression β ratio of diameters meter per meter m/m 1 β atomic oxygen to carbon ratio mole... consumption gram per kilowatt hour g/(kW·hr) g·3.6−1·106·m−2·kg·s2 F F-test statistic f frequency hertz Hz s−1... standard deviation S Sutherland constant kelvin K K SEE standard estimate of error T absolute temperature...

  16. 40 CFR 1065.1005 - Symbols, abbreviations, acronyms, and units of measure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... least squares regression β ratio of diameters meter per meter m/m 1 β atomic oxygen to carbon ratio mole... consumption gram per kilowatt hour g/(kW·hr) g·3.6−1·106·m−2·kg·s2 F F-test statistic f frequency hertz Hz s−1... standard deviation S Sutherland constant kelvin K K SEE standard estimate of error T absolute temperature...

  17. High School Students' Accuracy in Estimating the Cost of College: A Proposed Methodological Approach and Differences among Racial/Ethnic Groups and College Financial-Related Factors

    ERIC Educational Resources Information Center

    Nienhusser, H. Kenny; Oshio, Toko

    2017-01-01

    High school students' accuracy in estimating the cost of college (AECC) was examined by utilizing a new methodological approach, the absolute-deviation-continuous construct. This study used the High School Longitudinal Study of 2009 (HSLS:09) data and examined 10,530 11th grade students in order to measure their AECC for 4-year public and private…

  18. [Noninvasive total hemoglobin monitoring based on multiwave spectrophotometry in obstetrics and gynecology].

    PubMed

    Pyregov, A V; Ovechkin, A Iu; Petrov, S V

    2012-01-01

    Results of prospective randomized comparative research of 2 total hemoglobin estimation methods are presented. There were laboratory tests and continuous noninvasive technique with multiwave spectrophotometry on the Masimo Rainbow SET. Research was carried out in two stages. At the 1st stage (gynecology)--67 patients were included and in second stage (obstetrics)--44 patients during and after Cesarean section. The standard deviation of noninvasive total hemoglobin estimation from absolute values (invasive) was 7.2 and 4.1%, an standard deviation in a sample--5.2 and 2.7 % in gynecologic operations and surgical delivery respectively, that confirms lack of reliable indicators differences. The method of continuous noninvasive total hemoglobin estimation with multiwave spectrophotometry on the Masimo Rainbow SET technology can be recommended for use in obstetrics and gynecology.

  19. Measuring the rate of change of voice fundamental frequency in fluent speech during mental depression.

    PubMed

    Nilsonne, A; Sundberg, J; Ternström, S; Askenfelt, A

    1988-02-01

    A method of measuring the rate of change of fundamental frequency has been developed in an effort to find acoustic voice parameters that could be useful in psychiatric research. A minicomputer program was used to extract seven parameters from the fundamental frequency contour of tape-recorded speech samples: (1) the average rate of change of the fundamental frequency and (2) its standard deviation, (3) the absolute rate of fundamental frequency change, (4) the total reading time, (5) the percent pause time of the total reading time, (6) the mean, and (7) the standard deviation of the fundamental frequency distribution. The method is demonstrated on (a) a material consisting of synthetic speech and (b) voice recordings of depressed patients who were examined during depression and after improvement.

  20. Aircraft noise-induced awakenings are more reasonably predicted from relative than from absolute sound exposure levels.

    PubMed

    Fidell, Sanford; Tabachnick, Barbara; Mestre, Vincent; Fidell, Linda

    2013-11-01

    Assessment of aircraft noise-induced sleep disturbance is problematic for several reasons. Current assessment methods are based on sparse evidence and limited understandings; predictions of awakening prevalence rates based on indoor absolute sound exposure levels (SELs) fail to account for appreciable amounts of variance in dosage-response relationships and are not freely generalizable from airport to airport; and predicted awakening rates do not differ significantly from zero over a wide range of SELs. Even in conjunction with additional predictors, such as time of night and assumed individual differences in "sensitivity to awakening," nominally SEL-based predictions of awakening rates remain of limited utility and are easily misapplied and misinterpreted. Probabilities of awakening are more closely related to SELs scaled in units of standard deviates of local distributions of aircraft SELs, than to absolute sound levels. Self-selection of residential populations for tolerance of nighttime noise and habituation to airport noise environments offer more parsimonious and useful explanations for differences in awakening rates at disparate airports than assumed individual differences in sensitivity to awakening.

  1. Management of horses with focus on blanketing and clipping practices reported by members of the Swedish and Norwegian equestrian community.

    PubMed

    Hartmann, E; Bøe, K E; Jørgensen, G H M; Mejdell, C M; Dahlborn, K

    2017-03-01

    Limited information is available on the extent to which blankets are used on horses and the owners' reasoning behind clipping the horse's coat. Research on the effects of those practices on horse welfare is scarce but results indicate that blanketing and clipping may not be necessary from the horse's perspective and can interfere with the horse's thermoregulatory capacities. Therefore, this survey collected robust, quantitative data on the housing routines and management of horses with focus on blanketing and clipping practices as reported by members of the Swedish and Norwegian equestrian community. Horse owners were approached via an online survey, which was distributed to equestrian organizations and social media. Data from 4,122 Swedish and 2,075 Norwegian respondents were collected, of which 91 and 84% of respondents, respectively, reported using blankets on horses during turnout. Almost all respondents owning warmblood riding horses used blankets outdoors (97% in Sweden and 96% in Norway) whereas owners with Icelandic horses and coldblood riding horses used blankets significantly less ( < 0.05). Blankets were mainly used during rainy, cold, or windy weather conditions and in ambient temperatures of 10°C and below. The horse's coat was clipped by 67% of respondents in Sweden and 35% of Norwegian respondents whereby owners with warmblood horses and horses primarily used for dressage and competition reported clipping the coat most frequently. In contrast to scientific results indicating that recovery time after exercise increases with blankets and that clipped horses have a greater heat loss capacity, only around 50% of respondents agreed to these statements. This indicates that evidence-based information on all aspects of blanketing and clipping has not yet been widely distributed in practice. More research is encouraged, specifically looking at the effect of blankets on sweaty horses being turned out after intense physical exercise and the effect of blankets on social interactions such as mutual grooming. Future efforts should be tailored to disseminate knowledge more efficiently, which can ultimately stimulate thoughtful decision-making by horse owners concerning the use of blankets and clipping the horse's coat.

  2. Four-year trends in the treatment of cerebral aneurysms in Poland in 2009-2012.

    PubMed

    Tykocki, Tomasz; Kostyra, Kacper; Czyż, Marcin; Kostkiewicz, Bogusław

    2014-05-01

    The dilemma concerning the appropriate treatment of the intracranial aneurysms (IAs) has not yet been resolved and still remains under fierce debate. This study refers to the recent trends in the use of and outcomes related to coiling compared with clipping for unruptured and ruptured IAs in Poland over a 4-year period. The analysis refers to treatment of IAs performed in Poland between 2009-2012. Patients' records were cross-matched by ICD-9 codes for ruptured SAH (430) or unruptured cerebral aneurysm (437.3) along with codes for clipping (39.51) and coiling (39.79, 39.72, or 39.52). Multivariable logistic regression was used to compare in-hospital deaths, hospital length of stay (LOS), therapy allocation and aneurysm locations in unruptured vs. ruptured and clipped vs. coiled groups. Differences in the number of procedures between 16 administrative regions were standardized per 100,000 people. In 2009-2012, 11,051 procedures were identified, including 5,968 ruptured and 5,083 unruptured aneurysms. Overall increase was 2.3 % in clipping and 13.1 % in coiling; a significant trend was found in endovascular procedures (p = 0.044). Ruptured aneurysms were clipped more frequently (OR = 1.66;); in unruptured IAs, endovascular procedure was preferred 3.5 times more than clipping. The annual in-hospital mortality was 7.6 % in clipping and 6.7 % in endovascular treatment. LOS was two times longer after clipping in unruptured aneurysms (OR = 2.013). After the procedures were standardized per 100,000 people, the average for Poland was established as 9.09 in 2009, 10.86 in 2010, 10.55 in 2011, and 11.49 in 2012. This index had the highest values in Mazovia (12.9, 2009; 15.4, 2010; 17.4, 2011; 18.6, 2012. Data analysis revealed an increase in overall number of IAs treated in Poland between 2009-2012. A significant upward trend of endovascular procedures was found, whereas the number of clipped aneurysms remained relatively steady over the study period.

  3. PCLIPS: Parallel CLIPS

    NASA Technical Reports Server (NTRS)

    Gryphon, Coranth D.; Miller, Mark D.

    1991-01-01

    PCLIPS (Parallel CLIPS) is a set of extensions to the C Language Integrated Production System (CLIPS) expert system language. PCLIPS is intended to provide an environment for the development of more complex, extensive expert systems. Multiple CLIPS expert systems are now capable of running simultaneously on separate processors, or separate machines, thus dramatically increasing the scope of solvable tasks within the expert systems. As a tool for parallel processing, PCLIPS allows for an expert system to add to its fact-base information generated by other expert systems, thus allowing systems to assist each other in solving a complex problem. This allows individual expert systems to be more compact and efficient, and thus run faster or on smaller machines.

  4. Ischemic mass effect from biliary surgical clips.

    PubMed

    Mateo, Rod; Tsai, Steven; Stapfer, Maria V; Sher, Linda S; Selby, Rick; Genyk, Yuri S

    2008-02-01

    Migrating surgical clips in the hepatic hilum are known causes of biliary stricture or obstruction, most often due to direct intraluminal obstruction or secondary stone formation. Two cases are reported on patients with previous cholecystectomies presenting with delayed symptoms of biliary tract stricture. Both patients were successfully treated with a resection of the strictured area and a Roux-en-Y hepatico-jejunostomy. Resected specimens grossly demonstrated surgical clips adjacent to the stricture, but not directly within the lumen, suggestive of an ischemic mass effect, which was supported by histology. In addition to the direct intraluminal obstruction and lithogenic effects of migratory surgical clips, "clipomas" due to an ischemic mass effect can also lead to biliary tract strictures.

  5. Portable inference engine: An extended CLIPS for real-time production systems

    NASA Technical Reports Server (NTRS)

    Le, Thach; Homeier, Peter

    1988-01-01

    The present C-Language Integrated Production System (CLIPS) architecture has not been optimized to deal with the constraints of real-time production systems. Matching in CLIPS is based on the Rete Net algorithm, whose assumption of working memory stability might fail to be satisfied in a system subject to real-time dataflow. Further, the CLIPS forward-chaining control mechanism with a predefined conflict resultion strategy may not effectively focus the system's attention on situation-dependent current priorties, or appropriately address different kinds of knowledge which might appear in a given application. Portable Inference Engine (PIE) is a production system architecture based on CLIPS which attempts to create a more general tool while addressing the problems of real-time expert systems. Features of the PIE design include a modular knowledge base, a modified Rete Net algorithm, a bi-directional control strategy, and multiple user-defined conflict resolution strategies. Problems associated with real-time applications are analyzed and an explanation is given for how the PIE architecture addresses these problems.

  6. CLIP-related methodologies and their application to retrovirology.

    PubMed

    Bieniasz, Paul D; Kutluay, Sebla B

    2018-05-02

    Virtually every step of HIV-1 replication and numerous cellular antiviral defense mechanisms are regulated by the binding of a viral or cellular RNA-binding protein (RBP) to distinct sequence or structural elements on HIV-1 RNAs. Until recently, these protein-RNA interactions were studied largely by in vitro binding assays complemented with genetics approaches. However, these methods are highly limited in the identification of the relevant targets of RBPs in physiologically relevant settings. Development of crosslinking-immunoprecipitation sequencing (CLIP) methodology has revolutionized the analysis of protein-nucleic acid complexes. CLIP combines immunoprecipitation of covalently crosslinked protein-RNA complexes with high-throughput sequencing, providing a global account of RNA sequences bound by a RBP of interest in cells (or virions) at near-nucleotide resolution. Numerous variants of the CLIP protocol have recently been developed, some with major improvements over the original. Herein, we briefly review these methodologies and give examples of how CLIP has been successfully applied to retrovirology research.

  7. Using popular films to enhance classroom learning: the good, the bad, and the interesting.

    PubMed

    Butler, Andrew C; Zaromb, Franklin M; Lyle, Keith B; Roediger, Henry L

    2009-09-01

    Popular history films sometimes contain major historical inaccuracies. Two experiments investigated how watching such films influences people's ability to remember associated texts. Subjects watched film clips and studied texts about various historical topics. Whereas the texts contained only correct information, the film clips contained both correct information (consistent with the text) and misinformation (contradicted by the text). Before watching each clip, subjects received a specific warning, a general warning, or no warning about the misinformation. One week later, they returned for a cued-recall test about the texts. Watching a film clip increased correct recall of consistent information relative to recall of the same information when subjects did not see the clip. However, when the information in the film contradicted the text, subjects often (falsely) recalled misinformation from the film. The specific warning substantially reduced this misinformation effect. Teachers should use popular history films with caution and should warn students about major inaccuracies in the films.

  8. Optimizing assessment of sexual arousal in postmenopausal women using erotic film clips.

    PubMed

    Ramos Alarcon, Lauren G; Dai, Jing; Collins, Karen; Perez, Mindy; Woodard, Terri; Diamond, Michael P

    2017-10-01

    This study sought to assess sexual arousal in a subgroup of women by identifying erotic film clips that would be most mentally appealing and physically arousing to postmenopausal women. By measuring levels of mental appeal and self-reported physical arousal using a bidirectional scale, we aimed to elucidate the clips that would best be utilized for sexual health research in the postmenopausal or over 50-year-old subpopulation. Our results showed that postmenopausal women did not rate clips with older versus younger actors differently (p>0.05). The mean mental and mean physical scores were significantly correlated for both premenopausal subject ratings (r=0.69, p<0.001) and postmenopausal subject ratings (r=0.94, p<0.001). Thus postmenopausal women do not show a preference for the age of actors used in erotic film clips; this knowledge is relevant for design of future sexual function research. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. iCLIP reveals the function of hnRNP particles in splicing at individual nucleotide resolution

    PubMed Central

    König, Julian; Zarnack, Kathi; Rot, Gregor; Curk, Tomaž; Kayikci, Melis; Zupan, Blaž; Turner, Daniel J.; Luscombe, Nicholas M.; Ule, Jernej

    2010-01-01

    In the nucleus of eukaryotic cells, nascent transcripts are associated with heterogeneous nuclear ribonucleoprotein (hnRNP) particles that are nucleated by hnRNP C. Despite their abundance however, it remained unclear whether these particles control pre-mRNA processing. Here, we developed individual-nucleotide resolution UV-cross-linking and immunoprecipitation (iCLIP) to study the role of hnRNP C in splicing regulation. iCLIP data demonstrate that hnRNP C recognizes uridine tracts with a defined long-range spacing consistent with hnRNP particle organization. hnRNP particles assemble on both introns and exons, but remain generally excluded from splice sites. Integration of transcriptome-wide iCLIP data and alternative splicing profiles into an ‘RNA map’ indicates how the positioning of hnRNP particles determines their effect on inclusion of alternative exons. The ability of high-resolution iCLIP data to provide insights into the mechanism of this regulation holds promise for studies of other higher-order ribonucleoprotein complexes. PMID:20601959

  10. Nitinol Thermoreactive Clips for Secondary Sternal Closure in Cases of Noninfective Sternal Dehiscence

    PubMed Central

    Gucu, Arif; Toktas, Faruk; Eris, Cuneyt; Ata, Yusuf; Turk, Tamer

    2012-01-01

    Postoperative sternal dehiscence is a potentially catastrophic sequela to median sternotomy that can cause not only chest-wall discomfort and pulmonary dysfunction but infection, both superficial and mediastinal. Nitinol thermoreactive clips use a novel material in the treatment of sternal dehiscence. We sought to determine whether the use of these clips is an effective remedy for noninfective sternal dehiscence. From January 2008 through December 2011, we retrospectively studied the data on 10 patients whose sternums had been closed with nitinol thermoreactive clips after the development of noninfective sternal dehiscence. Diagnosis was made on the bases of clinical criteria, chest radiography, and microbiological investigation. There was no control group. No procedure-related sequelae occurred. There was no recurrent sternal instability and dehiscence, sternal-related hemorrhage, superficial wound infection, or mediastinal infection. We believe that the use of nitinol thermoreactive clips is a safe, easy, and efficient method of secondary sternal closure for noninfective sternal dehiscence. PMID:22949767

  11. Judgments of Nonverbal Behaviour by Children with High-Functioning Autism Spectrum Disorder: Can They Detect Signs of Winning and Losing from Brief Video Clips?

    ERIC Educational Resources Information Center

    Ryan, Christian; Furley, Philip; Mulhall, Kathleen

    2016-01-01

    Typically developing children are able to judge who is winning or losing from very short clips of video footage of behaviour between active match play across a number of sports. Inferences from "thin slices" (short video clips) allow participants to make complex judgments about the meaning of posture, gesture and body language. This…

  12. A Simple Recipe for Whitening Old Newspaper Clippings

    NASA Astrophysics Data System (ADS)

    Carter, Henry A.

    1995-07-01

    Newspaper clippings tend to brown quickly with aging as the result of chromophores that form during the degradation of one or more components of paper. Newsprint that consists of approximately 40% lignin is particularly susceptible to browning due to the relative ease of the oxidation of lignin. For readers who wish to experiment with both whitening and deacidifying old newspaper clippings, a simple recipe requiring few materials is presented.

  13. CLIP-seq analysis of multi-mapped reads discovers novel functional RNA regulatory sites in the human transcriptome.

    PubMed

    Zhang, Zijun; Xing, Yi

    2017-09-19

    Crosslinking or RNA immunoprecipitation followed by sequencing (CLIP-seq or RIP-seq) allows transcriptome-wide discovery of RNA regulatory sites. As CLIP-seq/RIP-seq reads are short, existing computational tools focus on uniquely mapped reads, while reads mapped to multiple loci are discarded. We present CLAM (CLIP-seq Analysis of Multi-mapped reads). CLAM uses an expectation-maximization algorithm to assign multi-mapped reads and calls peaks combining uniquely and multi-mapped reads. To demonstrate the utility of CLAM, we applied it to a wide range of public CLIP-seq/RIP-seq datasets involving numerous splicing factors, microRNAs and m6A RNA methylation. CLAM recovered a large number of novel RNA regulatory sites inaccessible by uniquely mapped reads. The functional significance of these sites was demonstrated by consensus motif patterns and association with alternative splicing (splicing factors), transcript abundance (AGO2) and mRNA half-life (m6A). CLAM provides a useful tool to discover novel protein-RNA interactions and RNA modification sites from CLIP-seq and RIP-seq data, and reveals the significant contribution of repetitive elements to the RNA regulatory landscape of the human transcriptome. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  14. Speed Biases With Real-Life Video Clips

    PubMed Central

    Rossi, Federica; Montanaro, Elisa; de’Sperati, Claudio

    2018-01-01

    We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion), speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion) to 32% (physical motion). Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate “natural” video compression techniques based on sub-threshold temporal squeezing. PMID:29615875

  15. Speed Biases With Real-Life Video Clips.

    PubMed

    Rossi, Federica; Montanaro, Elisa; de'Sperati, Claudio

    2018-01-01

    We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion), speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion) to 32% (physical motion). Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate "natural" video compression techniques based on sub-threshold temporal squeezing.

  16. [Correction of aphakia with the implantation of the retropupillary iris clip intraocular artificial lens].

    PubMed

    Szabó, Antal; Papp, András; Borbándy, Ágnes; D Géhl, Zsuzsanna; Nagy, Zoltán Zsolt; Resch, Miklós

    2017-01-01

    The correction of aphakia might be a challenge for the surgeon. The aim of this study is to describe the authors' experience with the implantation of the retropupillary iris clip intraocular lens. Patients between January 2014 and December 2015 were included in the retrospective study. Retropupillary implantation of iris clip intraocular lens VRSA 54 (AMO Advanced Medical Optics, USA) was performed in all cases. The minimum follow up period was three months. The stability of the intraocular lens and the intraoperative and postoperative complications and the visual acuity were evaluated. During this time period 11 cases (1 female, 10 males) were included in the study. The mean age at the time of the implantation was 57.7 years (between 25-74 years). In 4 cases the iris clip lens was implanted during the first intervention, in 7 cases during the secondary procedure. In all cases the lens was fixated onto the iris posteriorly. The best corrected visual acuity before the iris clip implantation was 0.43 (0.1-1.0) and postoperatively at the time of the follow up 0.49 (0.04-1.0). With the use of the retropupillary implanted iris clip intraocular lens all of the patients could have been rehabilitated without major complications. Orv. Hetil., 2017, 158(1), 20-24.

  17. Integrating Commercial Off-The-Shelf (COTS) graphics and extended memory packages with CLIPS

    NASA Technical Reports Server (NTRS)

    Callegari, Andres C.

    1990-01-01

    This paper addresses the question of how to mix CLIPS with graphics and how to overcome PC's memory limitations by using the extended memory available in the computer. By adding graphics and extended memory capabilities, CLIPS can be converted into a complete and powerful system development tool, on the other most economical and popular computer platform. New models of PCs have amazing processing capabilities and graphic resolutions that cannot be ignored and should be used to the fullest of their resources. CLIPS is a powerful expert system development tool, but it cannot be complete without the support of a graphics package needed to create user interfaces and general purpose graphics, or without enough memory to handle large knowledge bases. Now, a well known limitation on the PC's is the usage of real memory which limits CLIPS to use only 640 Kb of real memory, but now that problem can be solved by developing a version of CLIPS that uses extended memory. The user has access of up to 16 MB of memory on 80286 based computers and, practically, all the available memory (4 GB) on computers that use the 80386 processor. So if we give CLIPS a self-configuring graphics package that will automatically detect the graphics hardware and pointing device present in the computer, and we add the availability of the extended memory that exists in the computer (with no special hardware needed), the user will be able to create more powerful systems at a fraction of the cost and on the most popular, portable, and economic platform available such as the PC platform.

  18. Adjunctive intracardiac echocardiography imaging from the left ventricle to guide percutaneous mitral valve repair with the MitraClip in patients with failed prior surgical rings.

    PubMed

    Saji, Mike; Rossi, Ann M; Ailawadi, Gorav; Dent, John; Ragosta, Michael; Lim, D Scott

    2016-02-01

    We evaluated intracardiac echocardiography (ICE) for adjunctively guiding the MitraClip procedure in patients with prior surgical rings. Transesophageal echocardiography (TEE) is the standard imaging modality used to guide the MitraClip procedure (Abbott Vascular, CA). However, in patients with post-surgical anatomy, clear imaging of the mitral valve leaflets may be complex because of shadowing from the surgical ring. In these patients, TEE may be suboptimal for guiding the procedure, even using three-dimensional imaging. This retrospective analysis included data from 121 consecutive patients with mitral regurgitation who underwent MitraClip procedures at the University of Virginia. ICE was used adjunctively when there was difficulty with TEE, particularly for assessing the insertion of the posterior leaflet into the MitraClip's arms. The ICE catheter was introduced transarterially into the left ventricle and flexed to obtain the short-axis view. Six patients had prior surgical rings, and in five, we used adjunctive ICE. The etiology of the mitral regurgitation was prolapse of the posterior leaflet in one patient and restriction of the posterior leaflet due to ischemic tethering in the remainder. All images were obtained from the left ventricle, and were adequate for assessing posterior leaflet insertion and the perpendicularity of the MitraClip arms. The procedural success rate was 80%. There was no adverse event related to the ICE procedure. Mitral valve repair with the MitraClip system assisted by ICE is feasible in patients with prior surgical rings, achieving an excellent risk profile and satisfactory procedural success. © 2015 Wiley Periodicals, Inc.

  19. Mediastinal micro-vessels clipping during lymph node dissection may contribute to reduce postoperative pleural drainage

    PubMed Central

    Yan, Shi; Wang, Xing; Lv, Chao; Phan, Kevin; Wang, Yuzhao; Wang, Jia; Yang, Yue

    2016-01-01

    Background Postoperative pleural drainage markedly influences the length of postoperative stay and financial costs of medical care. The aim of this study is to retrospectively investigate potentially predisposing factors related to pleural drainage after curative thoracic surgery and to explore the impact of mediastinal micro-vessels clipping on pleural drainage control after lymph node dissection. Methods From February 2012 to November 2013, 322 consecutive cases of operable non-small cell lung cancers (NSCLC) undergoing lobectomy and mediastinal lymph node dissection with or without application of clipping were collected. Total and daily postoperative pleural drainage were recorded. Propensity score matching (1:2) was applied to balance variables potentially impacting pleural drainage between group clip and group control. Analyses were performed to compare drainage volume, duration of chest tube and postoperative hospital stay between the two groups. Variables linked with pleural drainage in whole cohort were assessed using multivariable logistic regression analysis. Results Propensity score matching resulted in 197 patients (matched cohort). Baseline patient characteristics were matched between two groups. Group clip showed less cumulative drainage volume (P=0.020), shorter duration of chest tube (P=0.031) and postoperative hospital stay (P=0.022) compared with group control. Risk factors significantly associated with high-output drainage in multivariable logistic regression analysis were being male, age >60 years, bilobectomy/sleeve lobectomy, pleural adhesion, the application of clip applier, duration of operation ≥220 minutes and chylothorax (P<0.05). Conclusions This study suggests that mediastinal micro-vessels clipping during lymph node dissection may reduce postoperative pleural drainage and thus shorten hospital stay. PMID:27076936

  20. The effects of media violence on anxiety in late adolescence.

    PubMed

    Madan, Anjana; Mrug, Sylvie; Wright, Rex A

    2014-01-01

    Exposure to media violence is related to anxiety in youth, but the causality of the effect has not been established. This experimental study examined the effects of media violence on anxiety, blood pressure, and heart rate in late adolescents. We also examined whether these responses varied by previous exposure to media and real-life violence. College students (N = 209; M age = 18.74; 75 % female; 50 % Caucasian, 34 % African American, 9 % Asian, 3 % Hispanic, and 3 % other racial minorities) were randomized to view either violent or nonviolent high-action movie clips. Participants reported on their anxiety before and after watching the clips, as well as their previous exposure to violence. Measures of blood pressure and heart rate were taken at baseline and during movie viewing. Participants watching violent movie clips showed a greater anxiety increase than those watching nonviolent clips. Both groups experienced increased blood pressure and reduced heart rate during movie watching compared to baseline. Prior exposure to media violence was associated with diminished heart rate response. Additionally, students previously exposed to high levels of real-life violence showed lower blood pressure increases when watching violent clips compared to nonviolent clips. Thus, relatively brief exposure to violent movie clips increased anxiety among late adolescents. Prior exposure to media and real-life violence were associated with lower physiological reactivity to high-action and violent movies, respectively, possibly indicating desensitization. Future studies should investigate long-term anxiety and physiological consequences of regular exposure to media violence in adolescence.

  1. A P300 event related potential technique for assessment of sexually oriented interest.

    PubMed

    Vardi, Yoram; Volos, Michal; Sprecher, Elliot; Granovsky, Yelena; Gruenwald, Ilan; Yarnitsky, David

    2006-12-01

    Despite all of the modern, sophisticated tests that exist for diagnosing and assessing male and female sexual disorders, to our knowledge there is no objective psychophysiological test to evaluate sexual arousal and interest. We provide preliminary data showing a decrease in auditory P300 wave amplitude during exposure to sexually explicit video clips and a significant correlation between the auditory P300 amplitude decrease and self-reported scores of sexual arousal and interest in the clips. A total of 30 healthy subjects were exposed to several blocks of auditory stimuli administered using an oddball paradigm. Baseline auditory P300 amplitudes were obtained and auditory stimuli were then delivered while viewing visual clips with 3 types of content, including sport, scenery and sex. Auditory P300 amplitude significantly decreased during viewing clips of all contents. Viewing sexual content clips caused a maximal decrease in P300 amplitude (p <0.0001). In addition, a high correlation was found between the amplitude decrease and scores on the sexual arousal questionnaire regarding the viewed clips (r = 0.61, p <0.001). In addition, the P300 amplitude decrease was significantly related to the sexual interest score (r = 0.37, p = 0.042) but not to interest in clips of nonsexual content. The change in auditory P300 amplitude during exposure to visual stimuli with sexual context seems to be an objective measure of subject sexual interest. This method might be applied to assess therapeutic intervention and as a diagnostic tool for assessing disorders of impaired libido or psychogenic sexual dysfunction.

  2. Treatment of Recurrent Intracranial Aneurysms After Clipping: A Report of 23 Cases and a Review of the Literature.

    PubMed

    Hokari, Masaaki; Kazumara, Ken; Nakayama, Naoki; Ushikoshi, Satoshi; Sugiyama, Taku; Asaoka, Katsunori; Uchida, Kazuki; Shimbo, Daisuke; Itamoto, Koji; Yokoyama, Yuka; Isobe, Masanori; Imai, Tetsuaki; Osanai, Toshiya; Houkin, Kiyohiro

    2016-08-01

    There are no established treatment strategies for aneurysms that recur after clipping. In this study, we present cases of patients who experienced recurrent aneurysms after clipping and subsequently underwent surgical intervention. Between 2004 and 2015, we surgically treated 23 aneurysms that recurred at a previously clipped site. Patient characteristics and clinical history were retrospectively reviewed. Patients included 19 women and 4 men 45-81 years old. Aneurysms recurred 3-31 years (mean, 15.4 years) after the initial operation. For 18 cases, the first clinical presentation was a subarachnoid hemorrhage; aneurysms were incidentally diagnosed in 5 patients. Aneurysm locations were as follows: 9 on the internal carotid artery; 4 on the middle cerebral artery; 7 on the anterior communicating artery; 2 on the distal anterior cerebral artery; and 1 on the basilar artery. The reasons for retreatment included subarachnoid hemorrhage (n = 9) and aneurysm regrowth detected on follow-up examinations (n = 14). Endovascular treatment was performed in 10 cases, and direct surgery was performed in 13 cases (clipping in 8, clipping or trapping with bypass in 5). Various complex vascular reconstructions, including high-flow bypass and intracranial-intracranial in situ bypass, were performed for recurrent aneurysms. In our experience, coil embolization is a safe and effective procedure for treating recurrent aneurysms. When cases are unsuitable for coil embolization, surgical treatment often requires neurosurgeons not only to overcome the general technical difficulty of reoperative clipping but also to perform challenging vascular reconstruction. Copyright © 2016. Published by Elsevier Inc.

  3. From tails to toes: developing nonlethal tissue indicators of mercury exposure in five amphibian species.

    PubMed

    Pfleeger, Adam Z; Eagles-Smith, Collin A; Kowalski, Brandon M; Herring, Garth; Willacker, James J; Jackson, Allyson K; Pierce, John R

    2016-04-01

    Exposure to environmental contaminants has been implicated as a factor in global amphibian decline. Mercury (Hg) is a particularly widespread contaminant that biomagnifies in amphibians and can cause a suite of deleterious effects. However, monitoring contaminant exposure in amphibian tissues may conflict with conservation goals if lethal take is required. Thus, there is a need to develop non-lethal tissue sampling techniques to quantify contaminant exposure in amphibians. Some minimally invasive sampling techniques, such as toe-clipping, are common in population-genetic research, but it is unclear if these methods can adequately characterize contaminant exposure. We examined the relationships between mercury (Hg) concentrations in non-lethally sampled tissues and paired whole-bodies in five amphibian species. Specifically, we examined the utility of three different tail-clip sections from four salamander species and toe-clips from one anuran species. Both tail and toe-clips accurately predicted whole-body THg concentrations, but the relationships differed among species and the specific tail-clip section or toe that was used. Tail-clips comprised of the distal 0-2 cm segment performed the best across all salamander species, explaining between 82 and 92% of the variation in paired whole-body THg concentrations. Toe-clips were less effective predictors of frog THg concentrations, but THg concentrations in outer rear toes accounted for up to 79% of the variability in frog whole-body THg concentrations. These findings suggest non-lethal sampling of tails and toes has potential applications for monitoring contaminant exposure and risk in amphibians, but care must be taken to ensure consistent collection and interpretation of samples.

  4. Training in Cerebral Aneurysm Clipping Using Self-Made 3-Dimensional Models.

    PubMed

    Mashiko, Toshihiro; Kaneko, Naoki; Konno, Takehiko; Otani, Keisuke; Nagayama, Rie; Watanabe, Eiju

    Recently, there have been increasingly fewer opportunities for junior surgeons to receive on-the-job training. Therefore, we created custom-built three-dimensional (3D) surgical simulators for training in connection with cerebral aneurysm clipping. Three patient-specific models were composed of a trimmed skull, retractable brain, and a hollow elastic aneurysm with its parent artery. The brain models were created using 3D printers via a casting technique. The artery models were made by 3D printing and a lost-wax technique. Four residents and 2 junior neurosurgeons attended the training courses. The trainees retracted the brain, observed the parent arteries and aneurysmal neck, selected the clip(s), and clipped the neck of an aneurysm. The duration of simulation was recorded. A senior neurosurgeon then assessed the trainee's technical skill and explained how to improve his/her performance for the procedure using a video of the actual surgery. Subsequently, the trainee attempted the clipping simulation again, using the same model. After the course, the senior neurosurgeon assessed each trainee's technical skill. The trainee critiqued the usefulness of the model and the effectiveness of the training course. Trainees succeeded in performing the simulation in line with an actual surgery. Their skills tended to improve upon completion of the training. These simulation models are easy to create, and we believe that they are very useful for training junior neurosurgeons in the surgical techniques needed for cerebral aneurysm clipping. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  5. Absolute extinction and the influence of environment - Dark cloud sight lines toward VCT 10, 30, and Walker 67

    NASA Technical Reports Server (NTRS)

    Cardelli, Jason A.; Clayton, Geoffrey C.

    1991-01-01

    The range of validity of the average absolute extinction law (AAEL) proposed by Cardelli et al. (1988 and 1989) is investigated, combining published visible and NIR data with IUE UV observations for three lines of sight through dense dark cloud environments with high values of total-to-selective extinction. The characteristics of the data sets and the reduction and parameterization methods applied are described in detail, and the results are presented in extensive tables and graphs. Good agreement with the AAEL is demonstrated for wavelengths from 3.4 microns to 250 nm, but significant deviations are found at shorter wavelengths (where previous studies of lines of sight through bright nebulosity found good agreement with the AAEL). These differences are attributed to the effects of coatings on small-bump and FUV grains.

  6. Dust-Corrected Star Formation Rates in Galaxies with Outer Rings

    NASA Astrophysics Data System (ADS)

    Kostiuk, I.; Silchenko, O.

    2018-03-01

    The star formation rates SFR, as well as the SFR surface densities ΣSFR and absolute stellar magnitudes MAB, are determined and corrected for interinsic dust absorption for 34 disk galaxies of early morphological types with an outer ring structure and ultraviolet emission from the ring. These characteristic are determined for the outer ring structures and for the galaxies as a whole. Data from the space telescopes GALEX (in the NUV and FUV ultraviolet ranges) and WISE (in the W4 22 μm infrared band) are used. The average relative deviation in the corrected SFR and ΣSFR derived from the NUV and FUV bands is only 19.0%, so their averaged values are used for statistical consideration. The relations between the dust-corrected SFR characteristics, UV colours, the galaxy morphological type, absolute magnitude are illustrated.

  7. Photon scattering cross sections of H2 and He measured with synchrotron radiation

    NASA Technical Reports Server (NTRS)

    Ice, G. E.

    1977-01-01

    Total (elastic + inelastic) differential photon scattering cross sections have been measured for H2 gas and He, using an X-ray beam. Absolute measured cross sections agree with theory within the probable errors. Relative cross sections (normalized to theory at large S) agree to better than one percent with theoretical values calculated from wave functions that include the effect of electron-electron Coulomb correlation, but the data deviate significantly from theoretical independent-particle (e.g., Hartree-Fock) results. The ratios of measured absolute He cross sections to those of H2, at any given S, also agree to better than one percent with theoretical He-to-H2 cross-section ratios computed from correlated wave functions. It appears that photon scattering constitutes a very promising tool for probing electron correlation in light atoms and molecules.

  8. The use of fractional orders in the determination of birefringence of highly dispersive materials by the channelled spectrum method

    NASA Astrophysics Data System (ADS)

    Nagarajan, K.; Shashidharan Nair, C. K.

    2007-07-01

    The channelled spectrum employing polarized light interference is a very convenient method for the study of dispersion of birefringence. However, while using this method, the absolute order of the polarized light interference fringes cannot be determined easily. Approximate methods are therefore used to estimate the order. One of the approximations is that the dispersion of birefringence across neighbouring integer order fringes is negligible. In this paper, we show how this approximation can cause errors. A modification is reported whereby the error in the determination of absolute fringe order can be reduced using fractional orders instead of integer orders. The theoretical background for this method supported with computer simulation is presented. An experimental arrangement implementing these modifications is described. This method uses a Constant Deviation Spectrometer (CDS) and a Soleil Babinet Compensator (SBC).

  9. 21 CFR 884.1720 - Gynecologic laparoscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...

  10. 21 CFR 884.1720 - Gynecologic laparoscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...

  11. 21 CFR 884.1720 - Gynecologic laparoscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...

  12. Comparison of the temperature accuracy between smart phone based and high-end thermal cameras using a temperature gradient phantom

    NASA Astrophysics Data System (ADS)

    Klaessens, John H.; van der Veen, Albert; Verdaasdonk, Rudolf M.

    2017-03-01

    Recently, low cost smart phone based thermal cameras are being considered to be used in a clinical setting for monitoring physiological temperature responses such as: body temperature change, local inflammations, perfusion changes or (burn) wound healing. These thermal cameras contain uncooled micro-bolometers with an internal calibration check and have a temperature resolution of 0.1 degree. For clinical applications a fast quality measurement before use is required (absolute temperature check) and quality control (stability, repeatability, absolute temperature, absolute temperature differences) should be performed regularly. Therefore, a calibrated temperature phantom has been developed based on thermistor heating on both ends of a black coated metal strip to create a controllable temperature gradient from room temperature 26 °C up to 100 °C. The absolute temperatures on the strip are determined with software controlled 5 PT-1000 sensors using lookup tables. In this study 3 FLIR-ONE cameras and one high end camera were checked with this temperature phantom. The results show a relative good agreement between both low-cost and high-end camera's and the phantom temperature gradient, with temperature differences of 1 degree up to 6 degrees between the camera's and the phantom. The measurements were repeated as to absolute temperature and temperature stability over the sensor area. Both low-cost and high-end thermal cameras measured relative temperature changes with high accuracy and absolute temperatures with constant deviations. Low-cost smart phone based thermal cameras can be a good alternative to high-end thermal cameras for routine clinical measurements, appropriate to the research question, providing regular calibration checks for quality control.

  13. Image Guidance in External Beam Accelerated Partial Breast Irradiation: Comparison of Surrogates for the Lumpectomy Cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasan, Yasmin; Kim, Leonard; Martinez, Alvaro

    Purpose: To compare localization of the lumpectomy cavity by using breast surface matching vs. clips for image-guided external beam accelerated partial breast irradiation. Methods and Materials: Twenty-seven patients with breast cancer with two computed tomography (CT) scans each had three CT registrations performed: (1) to bony anatomy, (2) to the center of mass (COM) of surgical clips, and (3) to the breast surface. The cavity COM was defined in both the initial and second CT scans after each type of registration, and distances between COMs ({delta}COM{sub Bone}, {delta}COM{sub Clips}, and {delta}COM{sub Surface}) were determined. Smaller {delta}COMs were interpreted as bettermore » localizations. Correlation coefficients were calculated for {delta}COM vs. several variables. Results: The {delta}COM{sub Bone} (mean, 7 {+-} 2 [SD] mm) increased with breast volume (r = 0.4; p = 0.02) and distance from the chest wall (r = 0.5; p = 0.003). Relative to bony registration, clip registration provided better localization ({delta}COM{sub Clips} < {delta}COM{sub Bone}) in 25 of 27 cases. Breast surface matching improved cavity localization ({delta}COM{sub Surface} < {delta}COM{sub Bone}) in 19 of 27 cases. Mean improvements ({delta}COM{sub Bone} - {delta}COM{sub ClipsorSurface}) were 4 {+-} 3 and 2 {+-} 4 mm, respectively. In terms of percentage of improvement ([{delta}COM{sub Bone} - {delta}COM{sub ClipsorSurface}]/{delta}COM{sub Bone}), only surface matching showed a correlation with breast volume. Clip localization outperformed surface registration for cavities located superior to the breast COM. Conclusions: Use of either breast surface or surgical clips as surrogates for the cavity results in improved localization in most patients compared with bony registration and may allow smaller planning target volume margins for external beam accelerated partial breast irradiation. Compared with surface registration, clip registration may be less sensitive to anatomic characteristics and therefore more broadly applicable.« less

  14. Clipping treatment of posterior communicating artery aneurysms associated with arteriosclerosis and calcification: A single center study of 136 cases

    PubMed Central

    Shi, Lei; Yu, Jing; Zhao, Ying; Xu, Kan; Yu, Jinlu

    2018-01-01

    It is widely acknowledged that arteriosclerosis and calcification of the parent artery and aneurysm neck make it difficult to clip posterior communicating artery (PCoA) aneurysms. A total of 136 cases of PCoA aneurysms accompanied by arteriosclerosis and calcification were collected and treated with clipping in the present study. Of the 136 patients, 112 were females (82.4%) and 24 were males (17.6%), with ages ranging from 37 to 76 years (mean age, 60.2 years). Rupture of a PCoA aneurysm was identified in 132 cases (97.1%), and there were 4 cases of unruptured PCoA aneurysms (2.9%). According to the severity of arteriosclerosis and calcification, the aneurysms were divided into type I, II or III. The treatment of type I aneurysms achieved the best curative effect. It is difficult to temporarily occlude type II and III aneurysms during surgery, and temporary occlusion failed in almost 50% of cases. Types II and III were prone to intraoperative aneurysm ruptures. A significantly higher rate of intraoperative aneurysm rupture was seen in type III compared with type II cases. Type II and III cases were more likely to be treated using a fenestrated clip for aneurysm clipping compared with type I cases, and fenestrated clips were used significantly more frequently in type III cases compared with type II cases. Arteriosclerosis and calcification were likely to affect the prognosis of patients, particularly in cases with type III arteriosclerosis and calcification of the parent artery and aneurysm neck. Therefore, the stratification of the arteriosclerosis and calcification of the parent artery and aneurysm neck into types I–III can guide the intraoperative aneurysm clipping strategy, aid in choosing the correct clips, and inform predictions of the occurrence of rupture and hemorrhage, as well as the prognosis for aneurysms. PMID:29434749

  15. Clipping treatment of posterior communicating artery aneurysms associated with arteriosclerosis and calcification: A single center study of 136 cases.

    PubMed

    Shi, Lei; Yu, Jing; Zhao, Ying; Xu, Kan; Yu, Jinlu

    2018-02-01

    It is widely acknowledged that arteriosclerosis and calcification of the parent artery and aneurysm neck make it difficult to clip posterior communicating artery (PCoA) aneurysms. A total of 136 cases of PCoA aneurysms accompanied by arteriosclerosis and calcification were collected and treated with clipping in the present study. Of the 136 patients, 112 were females (82.4%) and 24 were males (17.6%), with ages ranging from 37 to 76 years (mean age, 60.2 years). Rupture of a PCoA aneurysm was identified in 132 cases (97.1%), and there were 4 cases of unruptured PCoA aneurysms (2.9%). According to the severity of arteriosclerosis and calcification, the aneurysms were divided into type I, II or III. The treatment of type I aneurysms achieved the best curative effect. It is difficult to temporarily occlude type II and III aneurysms during surgery, and temporary occlusion failed in almost 50% of cases. Types II and III were prone to intraoperative aneurysm ruptures. A significantly higher rate of intraoperative aneurysm rupture was seen in type III compared with type II cases. Type II and III cases were more likely to be treated using a fenestrated clip for aneurysm clipping compared with type I cases, and fenestrated clips were used significantly more frequently in type III cases compared with type II cases. Arteriosclerosis and calcification were likely to affect the prognosis of patients, particularly in cases with type III arteriosclerosis and calcification of the parent artery and aneurysm neck. Therefore, the stratification of the arteriosclerosis and calcification of the parent artery and aneurysm neck into types I-III can guide the intraoperative aneurysm clipping strategy, aid in choosing the correct clips, and inform predictions of the occurrence of rupture and hemorrhage, as well as the prognosis for aneurysms.

  16. Hemodynamic response during aneurysm clipping surgery among experienced neurosurgeons.

    PubMed

    Bunevicius, Adomas; Bilskiene, Diana; Macas, Andrius; Tamasauskas, Arimantas

    2016-02-01

    Neurosurgery is a challenging field associated with high levels of mental stress. The goal of this study was to investigate the hemodynamic response of experienced neurosurgeons during aneurysm clipping surgery and to evaluate whether neurosurgeons' hemodynamic responses are associated with patients' clinical statuses. Four vascular neurosurgeons (all male; mean age 51 ± 10 years; post-residency experience ≥7 years) were studied during 42 aneurysm clipping procedures. Blood pressure (BP) and heart rate (HR) were assessed at rest and during seven phases of surgery: before the skin incision, after craniotomy, after dural opening, after aneurysm neck dissection, after aneurysm clipping, after dural closure and after skin closure. HR and BP were significantly greater during surgery relative to the rest situation (p ≤ 0.03). There was a statistically significant increase in neurosurgeons' HR (F [6, 41] = 10.88, p < 0.001), systolic BP (F [6, 41] = 2.97, p = 0.01), diastolic BP (F [6, 41] = 2.49, p = 0.02) and mean BP (F [6, 41] = 3.36, p = 0.003) during surgery. The greatest mean HR was after aneurysm clipping, and the greatest BP was after aneurysm neck dissection. Systolic, diastolic and mean BPs were significantly greater during surgical clipping for unruptured aneurysms compared to ruptured aneurysms across all stages of surgery (p ≤ 0.002); however, after adjusting for neurosurgeon experience, the difference in BP as a function of aneurysm rupture was not significant (p > 0.08). Aneurysm location, intraoperative aneurysm rupture, admission WFNS score, admission Glasgow Coma Scale scores and Fisher grade were not associated with neurosurgeons' intraoperative HR and BP (all p > 0.07). Aneurysm clipping surgery is associated with significant hemodynamic system activation among experienced neurosurgeons. The greatest HR and BP were after aneurysm neck dissection and clipping. Aneurysm location and patient clinical status were not associated with intraoperative changes of neurosurgeons' HR and BP.

  17. Psychophysiological Correlates of Sexually and Non-Sexually Motivated Attention to Film Clips in a Workload Task

    PubMed Central

    Carvalho, Sandra; Leite, Jorge; Galdo-Álvarez, Santiago; Gonçalves, Óscar F.

    2011-01-01

    Some authors have speculated that the cognitive component (P3) of the Event-Related Potential (ERP) can function as a psychophysiological measure of sexual interest. The aim of this study was to determine if the P3 ERP component in a workload task can be used as a specific and objective measure of sexual motivation by comparing the neurophysiologic response to stimuli of motivational relevance with different levels of valence and arousal. A total of 30 healthy volunteers watched different films clips with erotic, horror, social-positive and social-negative content, while answering an auditory oddball paradigm. Erotic film clips resulted in larger interference when compared to both the social-positive and auditory alone conditions. Horror film clips resulted in the highest levels of interference with smaller P3 amplitudes than erotic and also than social-positive, social-negative and auditory alone condition. No gender differences were found. Both horror and erotic film clips significantly decreased heart rate (HR) when compared to both social-positive and social-negative films. The erotic film clips significantly increased the skin conductance level (SCL) compared to the social-negative films. The horror film clips significantly increased the SCL compared to both social-positive and social-negative films. Both the highly arousing erotic and non-erotic (horror) movies produced the largest decrease in the P3 amplitude, a decrease in the HR and an increase in the SCL. These data support the notion that this workload task is very sensitive to the attentional resources allocated to the film clip, although they do not act as a specific index of sexual interest. Therefore, the use of this methodology seems to be of questionable utility as a specific measure of sexual interest or as an objective measure of the severity of Hypoactive Sexual Desire Disorder. PMID:22216305

  18. Psychophysiological correlates of sexually and non-sexually motivated attention to film clips in a workload task.

    PubMed

    Carvalho, Sandra; Leite, Jorge; Galdo-Álvarez, Santiago; Gonçalves, Oscar F

    2011-01-01

    Some authors have speculated that the cognitive component (P3) of the Event-Related Potential (ERP) can function as a psychophysiological measure of sexual interest. The aim of this study was to determine if the P3 ERP component in a workload task can be used as a specific and objective measure of sexual motivation by comparing the neurophysiologic response to stimuli of motivational relevance with different levels of valence and arousal. A total of 30 healthy volunteers watched different films clips with erotic, horror, social-positive and social-negative content, while answering an auditory oddball paradigm. Erotic film clips resulted in larger interference when compared to both the social-positive and auditory alone conditions. Horror film clips resulted in the highest levels of interference with smaller P3 amplitudes than erotic and also than social-positive, social-negative and auditory alone condition. No gender differences were found. Both horror and erotic film clips significantly decreased heart rate (HR) when compared to both social-positive and social-negative films. The erotic film clips significantly increased the skin conductance level (SCL) compared to the social-negative films. The horror film clips significantly increased the SCL compared to both social-positive and social-negative films. Both the highly arousing erotic and non-erotic (horror) movies produced the largest decrease in the P3 amplitude, a decrease in the HR and an increase in the SCL. These data support the notion that this workload task is very sensitive to the attentional resources allocated to the film clip, although they do not act as a specific index of sexual interest. Therefore, the use of this methodology seems to be of questionable utility as a specific measure of sexual interest or as an objective measure of the severity of Hypoactive Sexual Desire Disorder. © 2011 Carvalho et al.

  19. 21 CFR 884.1640 - Culdoscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... instruments include: lens cleaning brush, biopsy brush, clip applier (without clips), applicator, cannula... (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable) scissors, and suction/irrigation...

  20. 21 CFR 884.1640 - Culdoscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... instruments include: lens cleaning brush, biopsy brush, clip applier (without clips), applicator, cannula... (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable) scissors, and suction/irrigation...

  1. 21 CFR 884.1640 - Culdoscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... instruments include: lens cleaning brush, biopsy brush, clip applier (without clips), applicator, cannula... (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable) scissors, and suction/irrigation...

  2. The statistical properties and possible causes of polar motion prediction errors

    NASA Astrophysics Data System (ADS)

    Kosek, Wieslaw; Kalarus, Maciej; Wnek, Agnieszka; Zbylut-Gorska, Maria

    2015-08-01

    The pole coordinate data predictions from different prediction contributors of the Earth Orientation Parameters Combination of Prediction Pilot Project (EOPCPPP) were studied to determine the statistical properties of polar motion forecasts by looking at the time series of differences between them and the future IERS pole coordinates data. The mean absolute errors, standard deviations as well as the skewness and kurtosis of these differences were computed together with their error bars as a function of prediction length. The ensemble predictions show a little smaller mean absolute errors or standard deviations however their skewness and kurtosis values are similar as the for predictions from different contributors. The skewness and kurtosis enable to check whether these prediction differences satisfy normal distribution. The kurtosis values diminish with the prediction length which means that the probability distribution of these prediction differences is becoming more platykurtic than letptokurtic. Non zero skewness values result from oscillating character of these differences for particular prediction lengths which can be due to the irregular change of the annual oscillation phase in the joint fluid (atmospheric + ocean + land hydrology) excitation functions. The variations of the annual oscillation phase computed by the combination of the Fourier transform band pass filter and the Hilbert transform from pole coordinates data as well as from pole coordinates model data obtained from fluid excitations are in a good agreement.

  3. Accuracy of Lagrange-sinc functions as a basis set for electronic structure calculations of atoms and molecules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Sunghwan; Hong, Kwangwoo; Kim, Jaewook

    2015-03-07

    We developed a self-consistent field program based on Kohn-Sham density functional theory using Lagrange-sinc functions as a basis set and examined its numerical accuracy for atoms and molecules through comparison with the results of Gaussian basis sets. The result of the Kohn-Sham inversion formula from the Lagrange-sinc basis set manifests that the pseudopotential method is essential for cost-effective calculations. The Lagrange-sinc basis set shows faster convergence of the kinetic and correlation energies of benzene as its size increases than the finite difference method does, though both share the same uniform grid. Using a scaling factor smaller than or equal tomore » 0.226 bohr and pseudopotentials with nonlinear core correction, its accuracy for the atomization energies of the G2-1 set is comparable to all-electron complete basis set limits (mean absolute deviation ≤1 kcal/mol). The same basis set also shows small mean absolute deviations in the ionization energies, electron affinities, and static polarizabilities of atoms in the G2-1 set. In particular, the Lagrange-sinc basis set shows high accuracy with rapid convergence in describing density or orbital changes by an external electric field. Moreover, the Lagrange-sinc basis set can readily improve its accuracy toward a complete basis set limit by simply decreasing the scaling factor regardless of systems.« less

  4. Piezoelectric resonator assembly with thin molybdenum mounting clips

    DOEpatents

    Peters, R. Donald

    1981-01-01

    A resonator mounting assembly wherein the resonator blank is mounted agai an essentially planar surface presented by a plurality of peripherally disposed mounting clips and bonded to this surface to provide substantially all the mechanical support for the blank in a direction normal to the major faces of the resonator blank, while being flexible in the directions parallel to said major faces so as to minimize radial stresses on the resonator blank, particularly during thermal cycling of the resonator assembly. The clips are fabricated of a low thermal expansion material, such as molybdenum, which also has considerable yield strength after exposure to processing temperatures; the bonding of the clips to the edges of the resonator blank can be achieved by a polyimide containing electrically conductive particles.

  5. Expert networks in CLIPS

    NASA Technical Reports Server (NTRS)

    Hruska, S. I.; Dalke, A.; Ferguson, J. J.; Lacher, R. C.

    1991-01-01

    Rule-based expert systems may be structurally and functionally mapped onto a special class of neural networks called expert networks. This mapping lends itself to adaptation of connectionist learning strategies for the expert networks. A parsing algorithm to translate C Language Integrated Production System (CLIPS) rules into a network of interconnected assertion and operation nodes has been developed. The translation of CLIPS rules to an expert network and back again is illustrated. Measures of uncertainty similar to those rules in MYCIN-like systems are introduced into the CLIPS system and techniques for combining and hiring nodes in the network based on rule-firing with these certainty factors in the expert system are presented. Several learning algorithms are under study which automate the process of attaching certainty factors to rules.

  6. Image recognition of clipped stigma traces in rice seeds

    NASA Astrophysics Data System (ADS)

    Cheng, F.; Ying, YB

    2005-11-01

    The objective of this research is to develop algorithm to recognize clipped stigma traces in rice seeds using image processing. At first, the micro-configuration of clipped stigma traces was observed with electronic scanning microscope. Then images of rice seeds were acquired with a color machine vision system. A digital image-processing algorithm based on morphological operations and Hough transform was developed to inspect the occurrence of clipped stigma traces. Five varieties of Jinyou402, Shanyou10, Zhongyou207, Jiayou and you3207 were evaluated. The algorithm was implemented with all image sets using a Matlab 6.5 procedure. The results showed that the algorithm achieved an average accuracy of 96%. The algorithm was proved to be insensitive to the different rice seed varieties.

  7. Clip gage attachment for frictionless measurement of displacement during high-temperature mechanical testing

    DOEpatents

    Alexander, David J.

    1994-01-01

    An attachment for placement between a test specimen and a remote clip gage extensometer providing improved fracture toughness tests of materials at elevated temperature. Using a cylindrical tube and axial rod in new relationship, the device transfers the displacement signal of the fracture toughness test specimen directly to a clip gage extensometer located outside the high temperature furnace. Virtually frictionless operation is assured by having the test specimen center one end of the rod in one end of the tube, while the clip gage extensometer arms center the other end of the rod in the other end of the tube. By providing positive control over both ends of both rod and tube, the attachment may be operated in orientations other than vertical.

  8. Retrograde Suction Decompression with an Inahara Carotid Shunt for Clipping a Large Distal Internal Carotid Artery Aneurysm.

    PubMed

    Park, Yong Sook; Nam, Taek Kyun

    2017-03-01

    We describe a technique to clip a large internal carotid artery (ICA) aneurysm via a retrograde suction decompression (RSD). A large aneurysm in the right distal ICA involving the bifurcation region measuring 1.2×1.1×0.7 cm with posterior projection was managed with assisted RSD technique. The anterior choroidal artery emerged from the side wall of the aneurysm. An Inahara shunt was inserted into the ICA with neck dissection, and RSD was applied after completely clipping the aneurysm. RSD with an Inahara carotid shunt is useful for complete visualization of the aneurysm, including its surrounding structures, and for proximal control of the parent vessels, subsequently achieving satisfactory clip placement.

  9. Multi-focus image fusion based on area-based standard deviation in dual tree contourlet transform domain

    NASA Astrophysics Data System (ADS)

    Dong, Min; Dong, Chenghui; Guo, Miao; Wang, Zhe; Mu, Xiaomin

    2018-04-01

    Multiresolution-based methods, such as wavelet and Contourlet are usually used to image fusion. This work presents a new image fusion frame-work by utilizing area-based standard deviation in dual tree Contourlet trans-form domain. Firstly, the pre-registered source images are decomposed with dual tree Contourlet transform; low-pass and high-pass coefficients are obtained. Then, the low-pass bands are fused with weighted average based on area standard deviation rather than the simple "averaging" rule. While the high-pass bands are merged with the "max-absolute' fusion rule. Finally, the modified low-pass and high-pass coefficients are used to reconstruct the final fused image. The major advantage of the proposed fusion method over conventional fusion is the approximately shift invariance and multidirectional selectivity of dual tree Contourlet transform. The proposed method is compared with wavelet- , Contourletbased methods and other the state-of-the art methods on common used multi focus images. Experiments demonstrate that the proposed fusion framework is feasible and effective, and it performs better in both subjective and objective evaluation.

  10. The source parameters of 2013 Mw6.6 Lushan earthquake constrained with the restored local clipped seismic waveforms

    NASA Astrophysics Data System (ADS)

    Hao, J.; Zhang, J. H.; Yao, Z. X.

    2017-12-01

    We developed a method to restore the clipped seismic waveforms near epicenter using projection onto convex sets method (Zhang et al, 2016). This method was applied to rescue the local clipped waveforms of 2013 Mw 6.6 Lushan earthquake. We restored 88 out of 93 clipped waveforms of 38 broadband seismic stations of China Earthquake Networks (CEN). The epicenter distance of the nearest station to the epicenter that we can faithfully restore is only about 32 km. In order to investigate if the source parameters of earthquake could be determined exactly with the restored data, restored waveforms are utilized to get the mechanism of Lushan earthquake. We apply the generalized reflection-transmission coefficient matrix method to calculate the synthetic seismic records and simulated annealing method in inversion (Yao and Harkrider, 1983; Hao et al., 2012). We select 5 stations of CEN with the epicenter distance about 200km whose records aren't clipped and three-component velocity records are used. The result shows the strike, dip and rake angles of Lushan earthquake are 200o, 51o and 87o respectively, hereinafter "standard result". Then the clipped and restored seismic waveforms are applied respectively. The strike, dip and rake angles of clipped seismic waveforms are 184o, 53o and 72o respectively. The largest misfit of angle is 16o. In contrast, the strike, dip and rake angles of restored seismic waveforms are 198o, 51o and 87o respectively. It is very close to the "standard result". We also study the rupture history of Lushan earthquake constrained with the restored local broadband and teleseismic waves based on finite fault method (Hao et al., 2013). The result consists with that constrained with the strong motion and teleseismic waves (Hao et al., 2013), especially the location of the patch with larger slip. In real-time seismology, determining the source parameters as soon as possible is important. This method will help us to determine the mechanism of earthquake using the local clipped waveforms. Strong motion stations in China don't have good coverage at present. This method will help us to investigate the rupture history of large earthquake in China using the local clipped data of broadband stations.

  11. CLIPSITS - CLIPS INTELLIGENT TUTORING SYSTEM

    NASA Technical Reports Server (NTRS)

    Riley, G.

    1994-01-01

    The CLIPS Intelligent Tutoring System (CLIPSITS) is designed to be used to learn CLIPS, the C-language Integrated Production System expert system shell developed by the Software Technology Branch at Johnson Space Center. The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. This version of CLIPSITS is compatible with the Version 4.2 and 4.3 CLIPS User's Guide. However, the program does not cover any new features of CLIPS v4.3 that were added since the release of v4.2. The chapter numbers in the CLIPS User's Guide correspond directly with the lesson numbers in CLIPSITS. Each lesson in the program contains anywhere from 1 to 10 problems. Most of these have multiple parts. The student is given a subset of these problems from each lesson to work. The actual number of problems presented depends on how well the student masters the previous problem(s). The progression through these lessons is maintained in a personalized file under the student's name. As with most computer languages, there is usually more than one way to solve a problem. CLIPSITS attempts to be as flexible as possible and to allow as many correct solutions as possible. CLIPSITS gives the student the option of setting his/her own colors for the screen interface and the option of redefining special keystroke combinations used within the program. CLIPSITS requires an IBM PC compatible with 640K RAM and optional 2 or 3 button mouse. A 286- or 386-based machine is preferable. Performance will be somewhat slower on an XT class machine. The program must be installed on a hard disk with 825 KB space available. The program was developed in 1989. The standard distribution media is three 5.25" IBM PC DOS format diskettes. The program is also sold bundled with CLIPS for a special combined price as COS-10025. NOTE: Only the executable code is distributed. Supporting documentation is included on the diskettes. IBM, IBM PC and XT are registered trademarks of International Business Machines Corporation.

  12. Future of clip-on weapon sights: pros and cons from an applications perspective

    NASA Astrophysics Data System (ADS)

    Knight, C. Reed; Greenslade, Ken; Francisco, Glen

    2015-05-01

    US Domestic, International, allied Foreign National Warfighters and Para-Military First Responders (Police, SWAT, Special Operations, Law Enforcement, Government, Security and more) are put in harm's way all the time. To successfully complete their missions and return home safely are the primary goals of these professionals. Tactical product improvements that affect mission effectiveness and solider survivability are pivotal to understanding the past, present and future of Clip-On in-line weapon sights. Clip-On Weapon Sight (WS) technology was deemed an interim solution by the US Government for use until integrated and fused (day/night multi-sensor) Weapon Sights (WSs) were developed/fielded. Clip-On has now become the solution of choice by Users, Warriors, Soldiers and the US Government. SWaP-C (size, weight and power -cost) has been improved through progressive advances in Clip-On Image Intensified (I2), passive thermal, LL-CMOS and fused technology. Clip-On Weapon Sights are now no longer mounting position sensitive. Now they maintain aim point boresight, so they can be used for longer ranges with increased capabilities while utilizing the existing zeroed weapon and daysight optic. Active illuminated low-light level (both analog I2 and digital LL-CMOS) imaging is rightfully a real-world technology, proven to deliver daytime and low-light level identification confidence. Passive thermal imaging is also a real-world technology, proven to deliver daytime, nighttime and all-weather (including dirty battlefield) target detection confidence. Image processing detection algorithms with intelligent analytics provide documented promise to improve confidence by reducing Users, Warriors and Soldiers' work-loads and improving overall system engagement solution outcomes. In order to understand the future of Clip-On in-line weapon sights, addressing pros and cons, this paper starts with an overview of historical weapon sight applications, technologies and stakeholder decisions driving milestone events that helped shape the Clip-On weapon sight industry. Then, this paper systematically reviews current attributes of integrated multispectral wavelength electro-optical imaging systems that successfully (and sometimes unsuccessfully) shape today's Warrior, Soldier and User's net-capabilities. Finally, this paper explores the evolution, pros and cons, of future Clip-On weapon sights, from a manufacturing and real world applications perspective for tomorrow's military soldier and paramilitary first responder.

  13. No association between intraoperative hypothermia or supplemental protective drug and neurologic outcomes in patients undergoing temporary clipping during cerebral aneurysm surgery: findings from the Intraoperative Hypothermia for Aneurysm Surgery Trial.

    PubMed

    Hindman, Bradley J; Bayman, Emine O; Pfisterer, Wolfgang K; Torner, James C; Todd, Michael M

    2010-01-01

    Although hypothermia and barbiturates improve neurologic outcomes in animal temporary focal ischemia models, the clinical efficacy of these interventions during temporary occlusion of the cerebral vasculature during intracranial aneurysm surgery (temporary clipping) is not established. A post hoc analysis of patients from the Intraoperative Hypothermia for Aneurysm Surgery Trial who underwent temporary clipping was performed. Univariate and multivariate logistic regression methods were used to test for associations between hypothermia, supplemental protective drug, and short- (24-h) and long-term (3-month) neurologic outcomes. An odds ratio more than 1 denotes better outcome. Patients undergoing temporary clipping (n = 441) were assigned to intraoperative hypothermia (33.3 degrees +/- 0.8 degrees C, n = 208) or normothermia (36.7 degrees +/- 0.5 degrees C, n = 233), with 178 patients also receiving supplemental protective drug (thiopental or etomidate) during temporary clipping. Three months after surgery, 278 patients (63%) had good outcome (Glasgow Outcome Score = 1). Neither hypothermia (P = 0.847; odds ratio = 1.043, 95% CI = 0.678-1.606) nor supplemental protective drug (P = 0.835; odds ratio = 1.048, 95% CI = 0.674-1.631) were associated with 3-month Glasgow Outcome Score. The effect of supplemental protective drug did not significantly vary with temperature. The effects of hypothermia and protective drug did not significantly vary with temporary clip duration. Similar findings were made for 24-h neurologic status and 3-month Neuropsychological Composite Score. In the Intraoperative Hypothermia for Aneurysm Surgery Trial, neither systemic hypothermia nor supplemental protective drug affected short- or long-term neurologic outcomes of patients undergoing temporary clipping.

  14. Suitable closure for post-duodenal endoscopic resection taking medical costs into consideration

    PubMed Central

    Mori, Hirohito; Ayaki, Maki; Kobara, Hideki; Fujihara, Shintaro; Nishiyama, Noriko; Matsunaga, Tae; Yachida, Tatsuo; Masaki, Tsutomu

    2015-01-01

    AIM: To compare closure methods, closure times and medical costs between two groups of patients who had post-endoscopic resection (ER) artificial ulcer floor closures. METHODS: Nineteen patients with duodenal adenoma, early duodenal cancer, and subepithelial tumors that received ER between September 2009 and September 2014 at Kagawa University Hospital and Ehime Rosai Hospital, an affiliated hospital of Kagawa University, were included in the study. We retrospectively compared two groups of patients who received post-ER artificial ulcer floor closure: the conventional clip group vs the over-the-scope clip (OTSC) group. Delayed bleeding, procedure time of closure, delayed perforation, total number of conventional clips and OTSCs and medical costs were analyzed. RESULTS: Although we observed delayed bleeding in three patients in the conventional clip group, we observed no delayed bleeding in the OTSC group (P = 0.049). We did not observe perforation in either group. The mean procedure times for ulcer closure were 33.26 ± 12.57 min and 9.71 ± 2.92 min, respectively (P = 0.0001). The resection diameters were 18.8 ± 1.30 mm and 22.9 ± 1.21 mm for the conventional clip group and the OTSC group, respectively, with significant difference (P = 0.039). As for medical costs, the costs of all conventional clips were USD $1257 and the costs of OTSCs were $7850 (P = 0.005). If the post-ER ulcer is under 20 mm in diameter, a conventional clip closure may be more suitable with regard to the prevention of delayed perforation and to medical costs. CONCLUSION: If the post-ER ulcer is over 20 mm, the OTSC closure should be selected with regard to safety and reliable closure even if there are high medical costs. PMID:25954101

  15. Clinical outcomes and economic impact of transcatheter mitral leaflet repair in heart failure patients.

    PubMed

    Asgar, Anita W; Khairy, Paul; Guertin, Marie-Claude; Cournoyer, Daniel; Ducharme, Anique; Bonan, Raoul; Basmadjian, Arsene; Tardif, Jean-Claude; Cohen, David J

    2017-01-01

    Mitral regurgitation (MR) is a common valvular heart disorder requiring intervention once it becomes severe. Transcatheter mitral repair with the MitraClip device is a safe and effective therapy for selected patients denied surgery. The authors sought to evaluate the clinical outcomes and economic impact of this therapy compared to medical management in heart-failure patients with symptomatic mitral regurgitation. The study was comprised of two phases; an observational study of patients with heart failure and mitral regurgitation treated with either medical therapy or the MitraClip, and an economic model. Results of the observational study were used to estimate parameters for the decision model, which estimated costs, and benefits in a hypothetical cohort of patients with heart failure and moderate-to-severe mitral regurgitation treated with either standard medical therapy or MitraClip. The cohort of patients treated with the MitraClip was propensity matched to a population of heart failure patients, and their outcomes compared. At a mean follow-up of 22 months, all-cause mortality was 21% in the MitraClip cohort and 42% in the medical management cohort (p = .007). The decision model demonstrated that MitraClip increased life expectancy from 1.87-3.60 years and quality-adjusted life years (QALY) from 1.13-2.76 years. The incremental cost was $52,500 Canadian dollars, corresponding to an incremental cost-effectiveness ratio (ICER) of $32,300.00 per QALY gained. Results were sensitive to the survival benefit. In heart failure patients with symptomatic moderate-severe mitral regurgitation, therapy with the MitraClip is associated with superior survival and is cost-effective compared to medical therapy.

  16. Effects of precipitation and clipping intensity on net primary productivity and composition of a Leymus chinensis temperate grassland steppe.

    PubMed

    He, Feng; Wang, Kun; Hannaway, David B; Li, Xianglin

    2017-01-01

    Leymus chinensis (Trin.) is the dominant vegetation type in eastern Eurasian temperate grasslands but is decreasing due to the combined pressure of reduced precipitation and overgrazing. This study evaluated the separate and combined effects of precipitation and defoliation on net primary productivity (NPP) and composition of a L. chinensis steppe to promote the sustainable development of temperate grasslands through improved management practices. The effects of three precipitation gradients (precipitation unchanged, reduced by 50%, and increased by 50%) and two clipping intensities (clipping once or twice per year) were examined on NPP and composition of the L. chinensis community using a 7-year in situ controlled trial at the Guyuan State Key Monitoring and Research Station of Grassland Ecosystem in China. The results showed that: (1) a 50% reduction in natural precipitation significantly decreased NPP; a 50% increase in precipitation did not significantly increase NPP, but it decreased the importance value of L. chinensis because more water promoted the growth of competing species. (2) Clipping twice per year increased NPP, but the increase was from the dry matter of other species (DMO) component, and not from the dry matter of L. chinensis. (3) The standardized coefficients of a regression model (β) for DMO, NPP, and the importance value of L. chinensis were 0.685, 0.532, and -0.608 for precipitation, and 0.369, 0.419, and -0.276 for clipping mode, respectively. This study demonstrated that variation in precipitationis the key driver of NPP and composition of a L. chinensis steppe under the precipitation range and clipping intensities evaluated. This improved understanding of the effects of precipitation and clipping on NPP and composition will allow for improved, sustainable management of L. chinensis temperate grassland steppes.

  17. Clips versus suture technique: is there a difference?

    PubMed

    Chughtai, T; Chen, L Q; Salasidis, G; Nguyen, D; Tchervenkov, C; Morin, J F

    2000-11-01

    Coronary artery bypass grafting (CABG) is one of the most common procedures performed today, and wound complications are a major source of morbidity and cost. To determine whether there is any difference in wound outcome (including cost in a Canadian context) between a subcuticular suture technique and skin stapling technique for closure of sternal and leg incisions in CABG patients. One hundred and sixty-two patients undergoing CABG were prospectively, randomly placed to have their sternal and leg incisions closed with either a subcuticular suture technique or with a skin clip. Data were obtained through chart review, in-hospital assessments and follow-up visits. Nonblinded assessments were made regarding wound leakage, inflammation, infection, necrosis, swelling, dehiscence and cosmesis. Each of the parameters was graded on a scale from 1 to 4. The cost was evaluated in Canadian dollars. There were trends toward increased rates of in-hospital sternal (P=0.09) and leg (P=0.17) incision inflammation when the wounds were closed with skin clips. There was a significantly greater (P=0.05) rate of sternal wound infection with clips, as well as a tendency (P=0.15) toward a greater rate of mediastinitis at follow-up assessment. Cosmetic outcome was similar for both groups. The cost incurred was significantly greater when skin clips were used for closure. There was a greater than threefold difference, which translates to a greater than $10,000 difference over one year. Closure with a subcuticular technique achieves better outcomes than the use of skin clips. When factoring in the increased cost incurred by using clips, as well as other intangible factors such as surgical skill acquisition, subcuticular suture closure appears to be a favourable method of wound closure in CABG patients compared with the use of skin stapling techniques.

  18. Dosimetric impact of tumor bed delineation variability based on 4DCT scan for external-beam partial breast irradiation.

    PubMed

    Guo, Bing; Li, Jianbin; Wang, Wei; Li, Fengxiang; Guo, Yanluan; Li, Yankang; Liu, Tonghai

    2015-01-01

    This study sought to evaluate the dosimetric impact of tumor bed delineation variability (based on clips, seroma or both clips and seroma) during external-beam partial breast irradiation (EB-PBI) planned utilizing four-dimensional computed tomography (4DCT) scans. 4DCT scans of 20 patients with a seroma clarity score (SCS) 3~5 and ≥5 surgical clips were included in this study. The combined volume of the tumor bed formed using clips, seroma, or both clips and seroma on the 10 phases of 4DCT was defined as the internal gross target volume (termed IGTVC, IGTVS and IGTVC+S, respectively). A 1.5-cm margin was added by defining the planning target volume (termed PTVC, PTVS and PTVC+S, respectively). Three treatment plans were established using the 4DCT images (termed EB-PBIC, EB-PBIS, EB-PBIC+S, respectively). The results showed that the volume of IGTVC+S was significantly larger than that of IGTVCand IGTVS. Similarly, the volume of PTVC+S was markedly larger than that of PTVC and PTVS. However, the PTV coverage for EB-PBIC+S was similar to that of EB-PBIC and EB-PBIS, and there were no significant differences in the homogeneity index or conformity index between the three treatment plans (P=0.878, 0.086). The EB-PBIS plan resulted in the lowest ipsilateral normal breast and ipsilateral lung doses compared with the EB-PBIC and EB-PBIC+S plans. To conclude, the volume variability delineated based on clips, seroma or both clips and seroma resulted in dosimetric variability for organs at risk, but did not show a marked influence on the dosimetric distribution.

  19. Dosimetric impact of tumor bed delineation variability based on 4DCT scan for external-beam partial breast irradiation

    PubMed Central

    Guo, Bing; Li, Jianbin; Wang, Wei; Li, Fengxiang; Guo, Yanluan; Li, Yankang; Liu, Tonghai

    2015-01-01

    This study sought to evaluate the dosimetric impact of tumor bed delineation variability (based on clips, seroma or both clips and seroma) during external-beam partial breast irradiation (EB-PBI) planned utilizing four-dimensional computed tomography (4DCT) scans. 4DCT scans of 20 patients with a seroma clarity score (SCS) 3~5 and ≥5 surgical clips were included in this study. The combined volume of the tumor bed formed using clips, seroma, or both clips and seroma on the 10 phases of 4DCT was defined as the internal gross target volume (termed IGTVC, IGTVS and IGTVC+S, respectively). A 1.5-cm margin was added by defining the planning target volume (termed PTVC, PTVS and PTVC+S, respectively). Three treatment plans were established using the 4DCT images (termed EB-PBIC, EB-PBIS, EB-PBIC+S, respectively). The results showed that the volume of IGTVC+S was significantly larger than that of IGTVCand IGTVS. Similarly, the volume of PTVC+S was markedly larger than that of PTVC and PTVS. However, the PTV coverage for EB-PBIC+S was similar to that of EB-PBIC and EB-PBIS, and there were no significant differences in the homogeneity index or conformity index between the three treatment plans (P=0.878, 0.086). The EB-PBIS plan resulted in the lowest ipsilateral normal breast and ipsilateral lung doses compared with the EB-PBIC and EB-PBIC+S plans. To conclude, the volume variability delineated based on clips, seroma or both clips and seroma resulted in dosimetric variability for organs at risk, but did not show a marked influence on the dosimetric distribution. PMID:26885108

  20. Effects of precipitation and clipping intensity on net primary productivity and composition of a Leymus chinensis temperate grassland steppe

    PubMed Central

    Wang, Kun; Hannaway, David B.; Li, Xianglin

    2017-01-01

    Leymus chinensis (Trin.) is the dominant vegetation type in eastern Eurasian temperate grasslands but is decreasing due to the combined pressure of reduced precipitation and overgrazing. This study evaluated the separate and combined effects of precipitation and defoliation on net primary productivity (NPP) and composition of a L. chinensis steppe to promote the sustainable development of temperate grasslands through improved management practices. The effects of three precipitation gradients (precipitation unchanged, reduced by 50%, and increased by 50%) and two clipping intensities (clipping once or twice per year) were examined on NPP and composition of the L. chinensis community using a 7-year in situ controlled trial at the Guyuan State Key Monitoring and Research Station of Grassland Ecosystem in China. The results showed that: (1) a 50% reduction in natural precipitation significantly decreased NPP; a 50% increase in precipitation did not significantly increase NPP, but it decreased the importance value of L. chinensis because more water promoted the growth of competing species. (2) Clipping twice per year increased NPP, but the increase was from the dry matter of other species (DMO) component, and not from the dry matter of L. chinensis. (3) The standardized coefficients of a regression model (β) for DMO, NPP, and the importance value of L. chinensis were 0.685, 0.532, and −0.608 for precipitation, and 0.369, 0.419, and −0.276 for clipping mode, respectively. This study demonstrated that variation in precipitationis the key driver of NPP and composition of a L. chinensis steppe under the precipitation range and clipping intensities evaluated. This improved understanding of the effects of precipitation and clipping on NPP and composition will allow for improved, sustainable management of L. chinensis temperate grassland steppes. PMID:29287115

Top