Retractable pin dual in-line package test clip
Bandzuch, Gregory S.; Kosslow, William J.
1996-01-01
This invention is a Dual In-Line Package (DIP) test clip for use when troubleshooting circuits containing DIP integrated circuits. This test clip is a significant improvement over existing DIP test clips in that it has retractable pins which will permit troubleshooting without risk of accidentally shorting adjacent pins together when moving probes to different pins on energized circuits or when the probe is accidentally bumped while taking measurements.
ERIC Educational Resources Information Center
Tofel-Grehl, Colby; Litts, Breanne; Searle, Kristin
2016-01-01
Traditionally, electricity and circuits are taught using alligator clips, lightbulbs, batteries, and wires. Although these circuits engage students in building, they don't always provide opportunities for students to deeply explore energy, electricity, polarity, and circuitry. Multimedia Circuits is a curricular unit made up of three projects that…
Fixture aids soldering of electronic components on circuit board
NASA Technical Reports Server (NTRS)
Ross, M. H.
1966-01-01
Spring clamp fixture holds small electronic components in a desired position while they are being soldered on a circuit board. The spring clamp is clipped on the edge of the circuit board and an adjustable spring-steel boom holds components against the board. The felt pad at the end of the boom is replaced with different attachments for other holding tasks.
NASA Technical Reports Server (NTRS)
Britz, W. J.; Varnedoe, W. W., Jr.
1977-01-01
Rugged lamp used by miners is adapted for firefighters by utilization of smaller, rechargeable 3-hour-life gel-cell battery. Lighter, maintenance free unit can be clipped to outer clothing for convenience. Small monitor circuit indicates need to recharge battery.
Chaos in a neural network circuit
NASA Astrophysics Data System (ADS)
Kepler, Thomas B.; Datt, Sumeet; Meyer, Robert B.; Abott, L. F.
1990-12-01
We have constructed a neural network circuit of four clipped, high-grain, integrating operational amplifiers coupled to each other through an array of digitally programmable resistor ladders (MDACs). In addition to fixed-point and cyclic behavior, the circuit exhibits chaotic behavior with complex strange attractors which are approached through period doubling, intermittent attractor expansion and/or quasiperiodic pathways. Couplings between the nonlinear circuit elements are controlled by a computer which can automatically search through the space of couplings for interesting phenomena. We report some initial statistical results relating the behavior of the network to properties of its coupling matrix. Through these results and further research the circuit should help resolve fundamental issues concerning chaos in neural networks.
Matano, Fumihiro; Mizunari, Takayuki; Kominami, Shushi; Suzuki, Masanori; Fujiki, Yu; Kubota, Asami; Kobayashi, Shiro; Murai, Yasuo; Morita, Akio
2017-04-01
It is difficult to treat large internal carotid aneurysms with simple surgical clipping. Here, we present a retrograde suction decompression (RSD) procedure for large internal carotid aneurysms using a balloon guide catheter combined with a blood-returning circuit and a superficial temporal artery to middle cerebral artery (STA-MCA) bypass.All patients underwent an STA-MCA bypass before the temporary occlusion of the internal carotid artery (ICA). A 6-French sheath was inserted into the common carotid artery (CCA), and a 6-French Patrive balloon catheter was placed into the ICA 5 cm past the bifurcation. Aneurysm exposure was obtained; temporary clips were placed on the proximal M1, A1, and posterior communicating (Pcom) segments; and an extension tube was then connected to the balloon catheter. A three-way stopcock was placed, and aspiration was performed through the device to collapse the aneurysm. The aspirated blood was returned to a venous line with an added heparin to prevent anemia after aspiration. During the decompression, the blood flow to the cortical area was supplied through the STA-MCA bypass. After the aneurysm collapse, the surgeon carefully dissected the perforating artery from the aneurysm dome or neck, and permanent clips were then placed on the aneurysm neck. Our procedure has several advantages, such as STA-MCA bypass without external carotid artery occlusion for preventing ischemic complications of the cortical area, anemia may be avoided because of the return of the aspirated blood, and a hybrid operation room is not required to perform this method.
On-clip high frequency reliability and failure test structures
Snyder, Eric S.; Campbell, David V.
1997-01-01
Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer.
NASA Astrophysics Data System (ADS)
Diaz Leon, Juan J.; Norris, Kate J.; Hartnett, Ryan J.; Garrett, Matthew P.; Tompa, Gary S.; Kobayashi, Nobuhiko P.
2016-08-01
Thermoelectric (TE) devices that produce electric power from heat are driven by a temperature gradient (Δ T = T_{{hot}} - T_{{cold}}, T hot: hot side temperature, T cold: cold side temperature) with respect to the average temperature ( T). While the resistance of TE devices changes as Δ T and/or T change, the current-voltage ( I- V) characteristics have consistently been shown to remain linear, which clips generated electric power ( P gen) within the given open-circuit voltage ( V OC) and short-circuit current ( I SC). This P gen clipping is altered when an appropriate nonlinearity is introduced to the I- V characteristics—increasing P gen. By analogy, photovoltaic cells with a large fill factor exhibit nonlinear I- V characteristics. In this paper, the concept of a unique TE device with nonlinear I- V characteristics is proposed and experimentally demonstrated. A single TE device with nonlinear I- V characteristics is fabricated by combining indium phosphide (InP) and silicon (Si) semiconductor nanowire networks. These TE devices show P gen that is more than 25 times larger than those of comparable devices with linear I- V characteristics. The plausible causes of the nonlinear I- V characteristics are discussed. The demonstrated concept suggests that there exists a new pathway to increase P gen of TE devices made of semiconductors.
On-clip high frequency reliability and failure test structures
Snyder, E.S.; Campbell, D.V.
1997-04-29
Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer. 22 figs.
2008-02-01
breathing circuit by a rubber mouthpiece and nose clip, and to a finger pulse oximeter unit (Model 8600, Nonin Medical, Inc., Plymouth, MN) to...SaO2 via noninvasive finger pulse oximetry (Model 8600, Nonin Medical, Inc, Plymouth, MN) were monitored continuously, and ratings of perceived...respectively. Arterialization was achieved by warming the hand in 43ºC water for 5 min prior to obtaining a 150 µL fingertip blood sample for the
NASA Astrophysics Data System (ADS)
Freedman, David S.; Schroeder, Joseph B.; Telian, Gregory I.; Zhang, Zhengyang; Sunil, Smrithi; Ritt, Jason T.
2016-12-01
Objective. Behavioral neuroscience studies in freely moving rodents require small, light-weight implants to facilitate neural recording and stimulation. Our goal was to develop an integrated package of 3D printed parts and assembly aids for labs to rapidly fabricate, with minimal training, an implant that combines individually positionable microelectrodes, an optical fiber, zero insertion force (ZIF-clip) headstage connection, and secondary recording electrodes, e.g. for electromyography (EMG). Approach. Starting from previous implant designs that position recording electrodes using a control screw, we developed an implant where the main drive body, protective shell, and non-metal components of the microdrives are 3D printed in parallel. We compared alternative shapes and orientations of circuit boards for electrode connection to the headstage, in terms of their size, weight, and ease of wire insertion. We iteratively refined assembly methods, and integrated additional assembly aids into the 3D printed casing. Main results. We demonstrate the effectiveness of the OptoZIF Drive by performing real time optogenetic feedback in behaving mice. A novel feature of the OptoZIF Drive is its vertical circuit board, which facilities direct ZIF-clip connection. This feature requires angled insertion of an optical fiber that still can exit the drive from the center of a ring of recording electrodes. We designed an innovative 2-part protective shell that can be installed during the implant surgery to facilitate making additional connections to the circuit board. We use this feature to show that facial EMG in mice can be used as a control signal to lock stimulation to the animal’s motion, with stable EMG signal over several months. To decrease assembly time, reduce assembly errors, and improve repeatability, we fabricate assembly aids including a drive holder, a drill guide, an implant fixture for microelectode ‘pinning’, and a gold plating fixture. Significance. The expanding capability of optogenetic tools motivates continuing development of small optoelectric devices for stimulation and recording in freely moving mice. The OptoZIF Drive is the first to natively support ZIF-clip connection to recording hardware, which further supports a decrease in implant cross-section. The integrated 3D printed package of drive components and assembly tools facilities implant construction. The easy interfacing and installation of auxiliary electrodes makes the OptoZIF Drive especially attractive for real time feedback stimulation experiments.
1989-05-19
were (a) the dicrotic notch (see Figure 1) had to be present (b) no truncation or clipping could be present (c) the falling portion after the dichrotic... dicrotic notch or closing of the aortic valve (see Figure 1). The analog signal is fed to a delta z rebalancing circuit which has a maximum D.C. limit in... notch had to be relatively linear and (d) there could be only moderate baseline drift (maximum of approximately 30 degree baseline angle with respect
Static inverter with synchronous output waveform synthesized by time-optimal-response feedback
NASA Technical Reports Server (NTRS)
Kernick, A.; Stechschulte, D. L.; Shireman, D. W.
1976-01-01
Time-optimal-response 'bang-bang' or 'bang-hang' technique, using four feedback control loops, synthesizes static-inverter sinusoidal output waveform by self-oscillatory but yet synchronous pulse-frequency-modulation (SPFM). A single modular power stage per phase of ac output entails the minimum of circuit complexity while providing by feedback synthesis individual phase voltage regulation, phase position control and inherent compensation simultaneously for line and load disturbances. Clipped sinewave performance is described under off-limit load or input voltage conditions. Also, approaches to high power levels, 3-phase arraying and parallel modular connection are given.
Saxena, Payal; Ji-Shin, Eun; Haito-Chavez, Yamile; Valeshabad, Ali K.; Akshintala, Venkata; Aguila, Gerard; Kumbhari, Vivek; Ruben, Dawn S.; Lennon, Anne-Marie; Singh, Vikesh; Canto, Marcia; Kalloo, Anthony; Khashab, Mouen A.
2014-01-01
Background/Aim: There are currently no data on the relative retention rates of the Instinct clip, Resolution clip, and QuickClip2Long. Also, it is unknown whether retention rate differs when clips are applied to ulcerated rather than normal mucosa. The aim of this study is to compare the retention rates of three commonly used endoscopic clips. Materials and Methods: Six pigs underwent upper endoscopy with placement of one of each of the three types of clips on normal mucosa in the gastric body. Three mucosal resections were also performed to create “ulcers”. Each ulcer was closed with placement of one of the three different clips. Repeat endoscopy was performed weekly for up to 4 weeks. Results: Only the Instinct and Resolution clips remained attached for the duration of the study (4 weeks). At each time point, a greater proportion of Instinct clips were retained on normal mucosa, followed by Resolution clips. QuickClip2Long had the lowest retention rate on normal mucosa. Similar retention rates of Instinct clips and Resolution clips were seen on simulated ulcers, although both were superior to QuickClip2Long. However, the difference did not reach statistical significance. All QuickClip2Long clips were dislodged at 4 weeks in both the groups. Conclusions: The Resolution and Instinct clips have comparable retention rates and both appeared to be better than the QuickClip2Long on normal mucosa-simulated ulcers; however this did not reach statistical significance. Both the Resolution clip and the Instinct clip may be preferred in clinical situations when long-term clip attachment is required, including marking of tumors for radiotherapy and anchoring feeding tubes or stents. Either of the currently available clips may be suitable for closure of iatrogenic mucosal defects without features of chronicity. PMID:25434317
Liquid cooled, linear focus solar cell receiver
Kirpich, A.S.
1983-12-08
Separate structures for electrical insulation and thermal conduction are established within a liquid cooled, linear focus solar cell receiver for use with parabolic or Fresnel optical concentrators. The receiver includes a V-shaped aluminum extrusion having a pair of outer faces each formed with a channel receiving a string of solar cells in thermal contact with the extrusion. Each cell string is attached to a continuous glass cover secured within the channel with spring clips to isolate the string from the external environment. Repair or replacement of solar cells is effected simply by detaching the spring clips to remove the cover/cell assembly without interrupting circulation of coolant fluid through the receiver. The lower surface of the channel in thermal contact with the cells of the string is anodized to establish a suitable standoff voltage capability between the cells and the extrusion. Primary electrical insulation is provided by a dielectric tape disposed between the coolant tube and extrusion. Adjacent solar cells are soldered to interconnect members designed to accommodate thermal expansion and mismatches. The coolant tube is clamped into the extrusion channel with a releasably attachable clamping strip to facilitate easy removal of the receiver from the coolant circuit.
Liquid cooled, linear focus solar cell receiver
Kirpich, Aaron S.
1985-01-01
Separate structures for electrical insulation and thermal conduction are established within a liquid cooled, linear focus solar cell receiver for use with parabolic or Fresnel optical concentrators. The receiver includes a V-shaped aluminum extrusion having a pair of outer faces each formed with a channel receiving a string of solar cells in thermal contact with the extrusion. Each cell string is attached to a continuous glass cover secured within the channel with spring clips to isolate the string from the external environment. Repair or replacement of solar cells is effected simply by detaching the spring clips to remove the cover/cell assembly without interrupting circulation of coolant fluid through the receiver. The lower surface of the channel in thermal contact with the cells of the string is anodized to establish a suitable standoff voltage capability between the cells and the extrusion. Primary electrical insulation is provided by a dielectric tape disposed between the coolant tube and extrusion. Adjacent solar cells are soldered to interconnect members designed to accommodate thermal expansion and mismatches. The coolant tube is clamped into the extrusion channel with a releasably attachable clamping strip to facilitate easy removal of the receiver from the coolant circuit.
dCLIP: a computational approach for comparative CLIP-seq analyses
2014-01-01
Although comparison of RNA-protein interaction profiles across different conditions has become increasingly important to understanding the function of RNA-binding proteins (RBPs), few computational approaches have been developed for quantitative comparison of CLIP-seq datasets. Here, we present an easy-to-use command line tool, dCLIP, for quantitative CLIP-seq comparative analysis. The two-stage method implemented in dCLIP, including a modified MA normalization method and a hidden Markov model, is shown to be able to effectively identify differential binding regions of RBPs in four CLIP-seq datasets, generated by HITS-CLIP, iCLIP and PAR-CLIP protocols. dCLIP is freely available at http://qbrc.swmed.edu/software/. PMID:24398258
DAI-CLIPS: Distributed, Asynchronous, Interacting CLIPS
NASA Technical Reports Server (NTRS)
Gagne, Denis; Garant, Alain
1994-01-01
DAI-CLIPS is a distributed computational environment within which each CLIPS is an active independent computational entity with the ability to communicate freely with other CLIPS. Furthermore, new CLIPS can be created, others can be deleted or modify their expertise, all dynamically in an asynchronous and independent fashion during execution. The participating CLIPS are distributed over a network of heterogeneous processors taking full advantage of the available processing power. We present the general framework encompassing DAI-CLIPS and discuss some of its advantages and potential applications.
Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula
2018-02-01
The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
1989-01-01
C Language Integrated Production System (CLIPS) is a software shell for developing expert systems is designed to allow research and development of artificial intelligence on conventional computers. Originally developed by Johnson Space Center, it enables highly efficient pattern matching. A collection of conditions and actions to be taken if the conditions are met is built into a rule network. Additional pertinent facts are matched to the rule network. Using the program, E.I. DuPont de Nemours & Co. is monitoring chemical production machines; California Polytechnic State University is investigating artificial intelligence in computer aided design; Mentor Graphics has built a new Circuit Synthesis system, and Brooke and Brooke, a law firm, can determine which facts from a file are most important.
Intraoperative loss of core biopsy clips: clinical implications.
Calhoun, Kristine; Giuliano, Armando; Brenner, R James
2008-03-01
The purpose of this study was to report the occurrence of intraoperative loss of metallic marking clips placed during image-guided biopsy and to hypothesize the likely mechanism of this clinical problem. From January 2003 through December 2004, patients presenting for preoperative mammographic localization and operative excision of biopsy site marking clips were identified. Age, method of image-guided biopsy, number of excised specimens, and tissue diagnosis were determined. Specimen radiographs were used to identify cases of suspected intraoperative clip loss. Clips absent on specimen radiographs and postoperative mammograms were defined as lost intraoperatively. Biopsy site marking clips, surgical clips, and suction device apertures were measured. In 78 surgical procedures performed during the study period, three (3.8%) of the patients experienced clip loss. Specimen radiographs confirmed the absence of clips in all submitted tissues. A median of four (range, three to five) separate biopsy specimens were excised among these three cases. A healing biopsy site from the stereotactic biopsy preceding the clip placement procedure was confirmed in all cases. Absence of the metallic clip was confirmed on postoperative mammograms. The apertures of two types of suction device were four and two times those of the biopsy clips. Intraoperative loss of metallic clips placed at the conclusion of image-guided breast biopsy is unusual but can occur during subsequent surgical excision. Repeated inability to locate the clip on specimen radiographs after accurate preoperative localization should raise the suspicion that the target clip has been lost, not missed, during surgery, likely because of inadvertent removal of the clip with the suction device.
Three-Dimensional Printing of Surgical Clips: An In Vitro Pilot Study and Trial of Efficacy.
Canvasser, Noah E; De, Shuvro; Koseoglu, Ersin; Lay, Aaron H; Sorokin, Igor; Fernandez, Raul; Cadeddu, Jeffrey A
2017-09-01
Three-dimensional (3D) printing applications have increased over the past decade. Our objective was to test rapid prototyping of a 3D printed surgical clip for intraoperative use. Our prototype was modeled after the 10 mm Weck ® Hem-o-lok ® polymer clip (Teleflex, Inc., Wayne, PA). A 3D computer-aided design model of the Hem-o-lok clip was reverse engineered using commercial microscopy and printing was done using an Objet Connex500 multijetting system (Stratasys, Eden Prairie, MN). The initial polymer was Objet VeroWhitePlus RGD835; the addition of Objet TangoBlackPlus FLX980 during the design process improved hinge flexibility. The 3D printed clips were then pressure tested on rubber Penrose tubing and compared in vitro versus commercial Hem-o-lok clips. Initial 3D printed clips were not functional as they split at the hinge upon closure of the clip jaws. Design changes were made to add Objet TangoBlackPlus FLX980 at the hinge to improve flexibility. Additional modifications were made to allow for clips to be compatible with the Hem-o-lok endoscopic clip applier. A total of 50 clips were tested. Fracture rate for the printed clips using a clip applier was 54% (n = 27), whereas none of the commercial Hem-o-lok clips broke upon closure. Of the 23 printed clips that closed, mean leak was at 20.7 κPa (range 4.8-42.7). In contrast, none of the commercial clips leaked, and fill continued until Penrose rupture at mean 46.2 κPa (44.8-47.6). This pilot study demonstrates feasibility of 3D printing functional surgical clips. However, the performance of our first generation clips is poor compared with commercial grade product. Refinement in printers and materials available may allow for customization of such printed surgical instruments that could be economically competitive to purchasing and stocking product.
Correction of clipped pixels in color images.
Xu, Di; Doutre, Colin; Nasiopoulos, Panos
2011-03-01
Conventional images store a very limited dynamic range of brightness. The true luma in the bright area of such images is often lost due to clipping. When clipping changes the R, G, B color ratios of a pixel, color distortion also occurs. In this paper, we propose an algorithm to enhance both the luma and chroma of the clipped pixels. Our method is based on the strong chroma spatial correlation between clipped pixels and their surrounding unclipped area. After identifying the clipped areas in the image, we partition the clipped areas into regions with similar chroma, and estimate the chroma of each clipped region based on the chroma of its surrounding unclipped region. We correct the clipped R, G, or B color channels based on the estimated chroma and the unclipped color channel(s) of the current pixel. The last step involves smoothing of the boundaries between regions of different clipping scenarios. Both objective and subjective experimental results show that our algorithm is very effective in restoring the color of clipped pixels. © 2011 IEEE
Caputo, Antonio; Schmidt, Arthur; Caca, Karel; Bauerfeind, Peter; Schostek, Sebastian; Ho, Chi-Nghia; Gottwald, Thomas; Schurr, Marc O
2018-06-01
The remOVE System (Ovesco Endoscopy AG, Tuebingen, Germany) is a medical device for the endoscopic removal of OTSC or FTRD clips (Ovesco Endoscopy AG, Tuebingen, Germany). The aim of this paper is to assess the efficacy and safety of this system. A total of 74 patients underwent clip extraction. The standard removal procedure comprises fragmenting the clip by applying an electrical direct current pulse at two opposing sides of the clip. Clip fragmentation was successful in 72 of 74 patients (97.3%). In two cases (2.7%) clip fragmentation was not possible. In nine cases (12.2%) a clip fragment could not be removed and was left in place. Complications occurred in three cases (4.1%): two minor bleedings near the clip removal site (2.7%), and one superficial mucosal tear resulting from clip fragment extraction (1.4%). Based on this study, the use of the remOVE System for OTSC or FTRD clip removal can be considered safe and effective.
Shao, Yu-Yun; Liu, Tsung-Hao; Lee, Ying-Hui; Hsu, Chih-Hung; Cheng, Ann-Lii
2016-07-01
The Cancer of the Liver Italian Program (CLIP) score is a commonly used staging system for hepatocellular carcinoma (HCC) helpful with predicting prognosis of advanced HCC. CLIP uses the Child-Turcotte-Pugh (CTP) score to evaluate liver reserve. A new scoring system, the albumin-bilirubin (ALBI) grade, has been proposed as they objectively evaluate liver reserve. We examined whether the modification of CLIP with ALBI retained its prognosis prediction for patients with advanced HCC. We included patients who received first-line antiangiogenic therapy for advanced HCC. Liver reserve was assessed using CTP and ALBI scores, which were then incorporated into CLIP and ALBI-CLIP, respectively. To assess their efficacies of prognostic prediction, the Cox's proportional hazard model and concordance indexes were used. A total of 142 patients were included; 137 of them were classified CTP A and 5 patients CTP B. Patients could be divided into four or five groups with different prognosis according to CLIP and ALBI-CLIP, respectively. Higher R(2) (0.249 vs 0.216) and lower Akaike information criterion (995.0 vs 1001.1) were observed for ALBI-CLIP than for CLIP in the Cox's model predicting overall survival. ALBI-CLIP remained an independent predictor for overall survival when CLIP and ALBI-CLIP were simultaneously incorporated in Cox's models allowing variable selection with adjustment for hepatitis etiology, treatment, and performance status. The concordance index was also higher for ALBI-CLIP than for CLIP (0.724 vs 0.703). Modification of CLIP scoring with ALBI, which objectively assesses liver reserve, retains and might have improved prognosis prediction for advanced HCC. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Rebleeding from clipped aneurysm after 35 years: Report of 2 cases
Ishida, Atsushi; Matsuo, Seigo; Asakuno, Keizoh; Nemoto, Akio; Niimura, Kaku; Yoshimoto, Haruko; Shiramizu, Hideki; Yuzawa, Miki
2015-01-01
Background: A successfully applied clip for a ruptured aneurysm keeps the aneurysm's neck closed, preventing rerupture throughout the patient's life. Unfortunately, rebleeding from a clipped aneurysm does occur, but the likelihood declines with time. Since relatively old people suffer from subarachnoid hemorrhage, they die from diseases other than rebleeding, such as cancer. Therefore, rebleeding from a clipped aneurysm after two decades is quite rare. Case Description: Here, we report 2 cases of rerupture after an extremely long time since the initial clipping. In both cases, the old clip was removed, and the regrown gourd-shaped aneurysm was successfully obliterated. The clips in both cases were submitted to their manufacturers and inspected thoroughly. They were found to be second-generation, stainless steel clips, and were almost intact, even keeping their closing forces. In both cases, the clip existed on the surface of the newly made dome, and the previous dome completely disappeared. Conclusions: We experienced 2 cases of rebleeding from the clipped aneurysm after 35 years. In one of the cases, the clip was a Yasargil second generation stainless steel clip that retained its mechanical properties and surface elemental composition in vivo for a long time. These cases should be informative as they show extremely long-term course of a clip applied for a ruptured aneurysm. PMID:26322244
Linzey, Joseph R; Chen, Kevin S; Savastano, Luis; Thompson, B Gregory; Pandey, Aditya S
2018-06-01
Brain shifts following microsurgical clip ligation of anterior communicating artery (ACoA) aneurysms can lead to mechanical compression of the optic nerve by the clip. Recognition of this condition and early repositioning of clips can lead to reversal of vision loss. The authors identified 3 patients with an afferent pupillary defect following microsurgical clipping of ACoA aneurysms. Different treatment options were used for each patient. All patients underwent reexploration, and the aneurysm clips were repositioned to prevent clip-related compression of the optic nerve. Near-complete restoration of vision was achieved at the last clinic follow-up visit in all 3 patients. Clip ligation of ACoA aneurysms has the potential to cause clip-related compression of the optic nerve. Postoperative visual examination is of utmost importance, and if any changes are discovered, reexploration should be considered as repositioning of the clips may lead to resolution of visual deterioration.
Automated rule-base creation via CLIPS-Induce
NASA Technical Reports Server (NTRS)
Murphy, Patrick M.
1994-01-01
Many CLIPS rule-bases contain one or more rule groups that perform classification. In this paper we describe CLIPS-Induce, an automated system for the creation of a CLIPS classification rule-base from a set of test cases. CLIPS-Induce consists of two components, a decision tree induction component and a CLIPS production extraction component. ID3, a popular decision tree induction algorithm, is used to induce a decision tree from the test cases. CLIPS production extraction is accomplished through a top-down traversal of the decision tree. Nodes of the tree are used to construct query rules, and branches of the tree are used to construct classification rules. The learned CLIPS productions may easily be incorporated into a large CLIPS system that perform tasks such as accessing a database or displaying information.
CLIPS++: Embedding CLIPS into C++
NASA Technical Reports Server (NTRS)
Obermeyer, Lance; Miranker, Daniel P.
1994-01-01
This paper describes a set of C++ extensions to the CLIPS language and their embodiment in CLIPS++. These extensions and the implementation approach of CLIPS++ provide a new level of embeddability with C and C++. These extensions are a C++ include statement and a defcontainer construct; (include (c++-header-file.h)) and (defcontainer (c++-type)). The include construct allows C++ functions to be embedded in both the LHS and RHS of CLIPS rules. The header file in an include construct is the same header file the programmer uses for his/her own C++ code, independent of CLIPS. The defcontainer construct allows the inference engine to treat C++ class instances as CLIPS deftemplate facts. Consequently existing C++ class libraries may be transparently imported into CLIPS. These C++ types may use advanced features like inheritance, virtual functions, and templates. The implementation has been tested with several class libraries, including Rogue Wave Software's Tools.h++, GNU's libg++, and USL's C++ Standard Components. The execution speed of CLIPS++ has been determined to be 5 to 700 times the execution speed of CLIPS 6.0 (10 to 20X typical).
CLIPS: An expert system building tool
NASA Technical Reports Server (NTRS)
Riley, Gary
1991-01-01
The C Language Integrated Production System (CLIPS) is an expert system building tool, which provides a complete environment for the development and delivery of rule and/or object based expert systems. CLIPS was specifically designed to provide a low cost option for developing and deploying expert system applications across a wide range of hardware platforms. The commercial potential of CLIPS is vast. Currently, CLIPS is being used by over 3,300 individuals throughout the public and private sector. Because the CLIPS source code is readily available, numerous groups have used CLIPS as a basis for their own expert system tools. To date, three commercially available tools have been derived from CLIPS. In general, the development of CLIPS has helped to improve the ability to deliver expert system technology throughout the public and private sectors for a wide range of applications and diverse computing environments.
DEMAID - A DESIGN MANAGER'S AID FOR INTELLIGENT DECOMPOSITION (SUN VERSION)
NASA Technical Reports Server (NTRS)
Rogers, J. L.
1994-01-01
Many engineering systems are large and multi-disciplinary. Before the design of new complex systems such as large space platforms can begin, the possible interactions among subsystems and their parts must be determined. Once this is completed the proposed system can be decomposed to identify its hierarchical structure. DeMAID (A Design Manager's Aid for Intelligent Decomposition) is a knowledge-based system for ordering the sequence of modules and identifying a possible multilevel structure for the design problem. DeMAID displays the modules in an N x N matrix format (called a design structure matrix) where a module is any process that requires input and generates an output. (Modules which generate an output but do not require an input, such as an initialization process, are also acceptable.) Although DeMAID requires an investment of time to generate and refine the list of modules for input, it could save a considerable amount of money and time in the total design process, particularly in new design problems where the ordering of the modules has not been defined. The decomposition of a complex design system into subsystems requires the judgement of the design manager. DeMAID reorders and groups the modules based on the links (interactions) among the modules, helping the design manager make decomposition decisions early in the design cycle. The modules are grouped into circuits (the subsystems) and displayed in an N x N matrix format. Feedback links, which indicate an iterative process, are minimized and only occur within a subsystem. Since there are no feedback links among the circuits, the circuits can be displayed in a multilevel format. Thus, a large amount of information is reduced to one or two displays which are stored for later retrieval and modification. The design manager and leaders of the design teams then have a visual display of the design problem and the intricate interactions among the different modules. The design manager could save a substantial amount of time if circuits on the same level of the multilevel structure are executed in parallel. DeMAID estimates the time savings based on the number of available processors. In addition to decomposing the system into subsystems, DeMAID examines the dependencies of a problem with independent variables and dependant functions. A dependency matrix is created to show the relationship. DeMAID is based on knowledge base techniques to provide flexibility and ease in adding new capabilities. Although DeMAID was originally written for design problems, it has proven to be very general in solving any problem which contains modules (processes) which take an input and generate an output. For example, one group is applying DeMAID to gain understanding of the data flow of a very large computer program. In this example, the modules are the subroutines of the program. The design manager begins the design of a system by determining the level of modules which need to be ordered. The level is the "granularity" of the problem. For example, the design manager may wish to examine disciplines (a coarse model), analysis programs, or the data level (a fine model). Once the system is divided into these modules, each module's input and output is determined, creating a data file for input to the main program. DeMAID is executed through a system of menus. The user has the choice to plan, schedule, display the N x N matrix, display the multilevel organization, or examine the dependency matrix. The main program calls a subroutine which reads a rule file and a data file, asserts facts into the knowledge base, and executes the inference engine of the artificial intelligence/expert systems program, CLIPS (C Language Integrated Production System). To determine the effects of changes in the design process, DeMAID includes a trace effects feature. There are two methods available to trace the effects of a change in the design process. The first method traces forward through the outputs to determine the effects of an output with respect to a change in a particular input. The second method traces backward to determine what modules must be re-executed if the output of a module must be recomputed. DeMAID is available in three machine versions: a Macintosh version which is written in Symantec's Think C 3.01, a Sun version, and an SGI IRIS version, both of which are written in C language. The Macintosh version requires system software 6.0.2 or later and CLIPS 4.3. The source code for the Macintosh version will not compile under version 4.0 of Think C; however, a sample executable is provided on the distribution media. QuickDraw is required for plotting. The Sun version requires GKS 4.1 graphics libraries, OpenWindows 3, and CLIPS 4.3. The SGI IRIS version requires CLIPS 4.3. Since DeMAID is not compatible with CLIPS 5.0 or later, the source code for CLIPS 4.3 is included on the distribution media; however, the documentation for CLIPS 4.3 is not included in the documentation package for DeMAID. It is available from COSMIC separately as the documentation for MSC-21208. The standard distribution medium for the Macintosh version of DeMAID is a set of four 3.5 inch 800K Macintosh format diskettes. The standard distribution medium for the Sun version of DeMAID is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. The standard distribution medium for the IRIS version is a .25 inch IRIX compatible streaming magnetic tape cartridge in UNIX tar format. All versions include sample input. DeMAID was originally developed for use on VAX VMS computers in 1989. The Macintosh version of DeMAID was released in 1991 and updated in 1992. The Sun version of DeMAID was released in 1992 and updated in 1993. The SGI IRIS version was released in 1993.
DEMAID - A DESIGN MANAGER'S AID FOR INTELLIGENT DECOMPOSITION (SGI IRIS VERSION)
NASA Technical Reports Server (NTRS)
Rogers, J. L.
1994-01-01
Many engineering systems are large and multi-disciplinary. Before the design of new complex systems such as large space platforms can begin, the possible interactions among subsystems and their parts must be determined. Once this is completed the proposed system can be decomposed to identify its hierarchical structure. DeMAID (A Design Manager's Aid for Intelligent Decomposition) is a knowledge-based system for ordering the sequence of modules and identifying a possible multilevel structure for the design problem. DeMAID displays the modules in an N x N matrix format (called a design structure matrix) where a module is any process that requires input and generates an output. (Modules which generate an output but do not require an input, such as an initialization process, are also acceptable.) Although DeMAID requires an investment of time to generate and refine the list of modules for input, it could save a considerable amount of money and time in the total design process, particularly in new design problems where the ordering of the modules has not been defined. The decomposition of a complex design system into subsystems requires the judgement of the design manager. DeMAID reorders and groups the modules based on the links (interactions) among the modules, helping the design manager make decomposition decisions early in the design cycle. The modules are grouped into circuits (the subsystems) and displayed in an N x N matrix format. Feedback links, which indicate an iterative process, are minimized and only occur within a subsystem. Since there are no feedback links among the circuits, the circuits can be displayed in a multilevel format. Thus, a large amount of information is reduced to one or two displays which are stored for later retrieval and modification. The design manager and leaders of the design teams then have a visual display of the design problem and the intricate interactions among the different modules. The design manager could save a substantial amount of time if circuits on the same level of the multilevel structure are executed in parallel. DeMAID estimates the time savings based on the number of available processors. In addition to decomposing the system into subsystems, DeMAID examines the dependencies of a problem with independent variables and dependant functions. A dependency matrix is created to show the relationship. DeMAID is based on knowledge base techniques to provide flexibility and ease in adding new capabilities. Although DeMAID was originally written for design problems, it has proven to be very general in solving any problem which contains modules (processes) which take an input and generate an output. For example, one group is applying DeMAID to gain understanding of the data flow of a very large computer program. In this example, the modules are the subroutines of the program. The design manager begins the design of a system by determining the level of modules which need to be ordered. The level is the "granularity" of the problem. For example, the design manager may wish to examine disciplines (a coarse model), analysis programs, or the data level (a fine model). Once the system is divided into these modules, each module's input and output is determined, creating a data file for input to the main program. DeMAID is executed through a system of menus. The user has the choice to plan, schedule, display the N x N matrix, display the multilevel organization, or examine the dependency matrix. The main program calls a subroutine which reads a rule file and a data file, asserts facts into the knowledge base, and executes the inference engine of the artificial intelligence/expert systems program, CLIPS (C Language Integrated Production System). To determine the effects of changes in the design process, DeMAID includes a trace effects feature. There are two methods available to trace the effects of a change in the design process. The first method traces forward through the outputs to determine the effects of an output with respect to a change in a particular input. The second method traces backward to determine what modules must be re-executed if the output of a module must be recomputed. DeMAID is available in three machine versions: a Macintosh version which is written in Symantec's Think C 3.01, a Sun version, and an SGI IRIS version, both of which are written in C language. The Macintosh version requires system software 6.0.2 or later and CLIPS 4.3. The source code for the Macintosh version will not compile under version 4.0 of Think C; however, a sample executable is provided on the distribution media. QuickDraw is required for plotting. The Sun version requires GKS 4.1 graphics libraries, OpenWindows 3, and CLIPS 4.3. The SGI IRIS version requires CLIPS 4.3. Since DeMAID is not compatible with CLIPS 5.0 or later, the source code for CLIPS 4.3 is included on the distribution media; however, the documentation for CLIPS 4.3 is not included in the documentation package for DeMAID. It is available from COSMIC separately as the documentation for MSC-21208. The standard distribution medium for the Macintosh version of DeMAID is a set of four 3.5 inch 800K Macintosh format diskettes. The standard distribution medium for the Sun version of DeMAID is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. The standard distribution medium for the IRIS version is a .25 inch IRIX compatible streaming magnetic tape cartridge in UNIX tar format. All versions include sample input. DeMAID was originally developed for use on VAX VMS computers in 1989. The Macintosh version of DeMAID was released in 1991 and updated in 1992. The Sun version of DeMAID was released in 1992 and updated in 1993. The SGI IRIS version was released in 1993.
DEMAID - A DESIGN MANAGER'S AID FOR INTELLIGENT DECOMPOSITION (MACINTOSH VERSION)
NASA Technical Reports Server (NTRS)
Rogers, J. L.
1994-01-01
Many engineering systems are large and multi-disciplinary. Before the design of new complex systems such as large space platforms can begin, the possible interactions among subsystems and their parts must be determined. Once this is completed the proposed system can be decomposed to identify its hierarchical structure. DeMAID (A Design Manager's Aid for Intelligent Decomposition) is a knowledge-based system for ordering the sequence of modules and identifying a possible multilevel structure for the design problem. DeMAID displays the modules in an N x N matrix format (called a design structure matrix) where a module is any process that requires input and generates an output. (Modules which generate an output but do not require an input, such as an initialization process, are also acceptable.) Although DeMAID requires an investment of time to generate and refine the list of modules for input, it could save a considerable amount of money and time in the total design process, particularly in new design problems where the ordering of the modules has not been defined. The decomposition of a complex design system into subsystems requires the judgement of the design manager. DeMAID reorders and groups the modules based on the links (interactions) among the modules, helping the design manager make decomposition decisions early in the design cycle. The modules are grouped into circuits (the subsystems) and displayed in an N x N matrix format. Feedback links, which indicate an iterative process, are minimized and only occur within a subsystem. Since there are no feedback links among the circuits, the circuits can be displayed in a multilevel format. Thus, a large amount of information is reduced to one or two displays which are stored for later retrieval and modification. The design manager and leaders of the design teams then have a visual display of the design problem and the intricate interactions among the different modules. The design manager could save a substantial amount of time if circuits on the same level of the multilevel structure are executed in parallel. DeMAID estimates the time savings based on the number of available processors. In addition to decomposing the system into subsystems, DeMAID examines the dependencies of a problem with independent variables and dependant functions. A dependency matrix is created to show the relationship. DeMAID is based on knowledge base techniques to provide flexibility and ease in adding new capabilities. Although DeMAID was originally written for design problems, it has proven to be very general in solving any problem which contains modules (processes) which take an input and generate an output. For example, one group is applying DeMAID to gain understanding of the data flow of a very large computer program. In this example, the modules are the subroutines of the program. The design manager begins the design of a system by determining the level of modules which need to be ordered. The level is the "granularity" of the problem. For example, the design manager may wish to examine disciplines (a coarse model), analysis programs, or the data level (a fine model). Once the system is divided into these modules, each module's input and output is determined, creating a data file for input to the main program. DeMAID is executed through a system of menus. The user has the choice to plan, schedule, display the N x N matrix, display the multilevel organization, or examine the dependency matrix. The main program calls a subroutine which reads a rule file and a data file, asserts facts into the knowledge base, and executes the inference engine of the artificial intelligence/expert systems program, CLIPS (C Language Integrated Production System). To determine the effects of changes in the design process, DeMAID includes a trace effects feature. There are two methods available to trace the effects of a change in the design process. The first method traces forward through the outputs to determine the effects of an output with respect to a change in a particular input. The second method traces backward to determine what modules must be re-executed if the output of a module must be recomputed. DeMAID is available in three machine versions: a Macintosh version which is written in Symantec's Think C 3.01, a Sun version, and an SGI IRIS version, both of which are written in C language. The Macintosh version requires system software 6.0.2 or later and CLIPS 4.3. The source code for the Macintosh version will not compile under version 4.0 of Think C; however, a sample executable is provided on the distribution media. QuickDraw is required for plotting. The Sun version requires GKS 4.1 graphics libraries, OpenWindows 3, and CLIPS 4.3. The SGI IRIS version requires CLIPS 4.3. Since DeMAID is not compatible with CLIPS 5.0 or later, the source code for CLIPS 4.3 is included on the distribution media; however, the documentation for CLIPS 4.3 is not included in the documentation package for DeMAID. It is available from COSMIC separately as the documentation for MSC-21208. The standard distribution medium for the Macintosh version of DeMAID is a set of four 3.5 inch 800K Macintosh format diskettes. The standard distribution medium for the Sun version of DeMAID is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. The standard distribution medium for the IRIS version is a .25 inch IRIX compatible streaming magnetic tape cartridge in UNIX tar format. All versions include sample input. DeMAID was originally developed for use on VAX VMS computers in 1989. The Macintosh version of DeMAID was released in 1991 and updated in 1992. The Sun version of DeMAID was released in 1992 and updated in 1993. The SGI IRIS version was released in 1993.
HyperCLIPS: A HyperCard interface to CLIPS
NASA Technical Reports Server (NTRS)
Pickering, Brad; Hill, Randall W., Jr.
1990-01-01
HyperCLIPS combines the intuitive, interactive user interface of the Apple Macintosh(TM) with the powerful symbolic computation of an expert system interpreter. HyperCard(TM) is an excellent environment for quickly developing the front end of an application with buttons, dialogs, and pictures, while the CLIPS interpreter provides a powerful inference engine for complex problem solving and analysis. By integrating HyperCard and CLIPS the advantages and uses of both packages are made available for a wide range of uses: rapid prototyping of knowledge-based expert systems, interactive simulations of physical systems, and intelligent control of hypertext processes, to name a few. Interfacing HyperCard and CLIPS is natural. HyperCard was designed to be extended through the use of external commands (XCMDs), and CLIPS was designed to be embedded through the use of the I/O router facilities and callable interface routines. With the exception of some technical difficulties which will be discussed later, HyperCLIPS implements this interface in a straight forward manner, using the facilities provided. An XCMD called 'ClipsX' was added to HyperCard to give access to the CLIPS routines: clear, load, reset, and run. And an I/O router was added to CLIPS to handle the communication of data between CLIPS and HyperCard.
Yoshida, Toshihiko; Fukumoto, Takumi; Urade, Takeshi; Kido, Masahiro; Toyama, Hirochika; Asari, Sadaki; Ajiki, Tetsuo; Ikeo, Naoko; Mukai, Toshiji; Ku, Yonson
2017-06-01
Operative clips used to ligate vessels in abdominal operation usually are made of titanium. They remain in the body permanently and form metallic artifacts in computed tomography images, which impair accurate diagnosis. Although biodegradable magnesium instruments have been developed in other fields, the physical properties necessary for operative clips differ from those of other instruments. We developed a biodegradable magnesium-zinc-calcium alloy clip with good biologic compatibility and enough clamping capability as an operative clip. In this study, we verified the safety and tolerability of this clip for use in canine cholecystectomy. Nine female beagles were used. We performed cholecystectomy and ligated the cystic duct by magnesium alloy or titanium clips. The chronologic change of clips and artifact formation were compared at 1, 4, 12, 18, and 24 weeks postoperative by computed tomography. The animals were killed at the end of the observation period, and the clips were removed to evaluate their biodegradability. We also evaluated their effect on the living body by blood biochemistry data. The magnesium alloy clip formed much fewer artifacts than the titanium clip, and it was almost absorbed at 6 months postoperative. There were no postoperative complications and no elevation of constituent elements such as magnesium, calcium, and zinc during the observation period in both groups. The novel magnesium alloy clip demonstrated sufficient sealing capability for the cystic duct and proper biodegradability in canine models. The magnesium alloy clip revealed much fewer metallic artifacts in CT than the conventional titanium clip. Copyright © 2016 Elsevier Inc. All rights reserved.
Comparison of holding strength of suture anchors for hepatic and renal parenchyma.
Ames, Caroline D; Perrone, Juan M; Frisella, Alison J; Morrissey, Kevin; Landman, Jaime
2005-12-01
Various laparoscopic devices have been described for suture anchoring during solidorgan parenchymal closure. Application of these devices expedites the closure of parenchymal defects and minimizes ischemia time. We compared different technologies as suture anchors for parenchymal closure. A tensometer was used to determine the amount of tension necessary to dislodge each of five different clips from Vicryl suture alone or against two different substrates (fresh pig kidney and liver) with and without an intervening pledget. The clips investigated were the Lapra-Ty (Ethicon), Endoclip II (US Surgical), small Horizon Ligating Clips (Weck), Hem-o-lok Medium Polymer Clips (Week), and a novel Suture-clip (Applied Medical). ANOVA and two-sided Fisher's exact test provided statistical analysis. The force required to dislodge the Lapra-Ty clip from bare suture for both 0 and 1 Vicryl (7.0 N) was approximately fourfold the force required to dislodge the Endoclips or the 5-mm or 10-mm Hem-o-lok clips (p<0.01). When clips were applied to suture running through renal or liver parenchyma, the novel Suture-clip required the greatest tension to dislodge (P<0.01), followed by the Horizon and Lapra-Ty clips. There were no statistically significant differences in the tension required to dislodge a given clip from the two parenchymal substrates or in the presence or absence of a pledget. In our experimental model, the Suture-clip, Lapra-Ty, and Horizon clips required significantly greater tension to dislodge than the Hem-o-lok and Endoclip clips. The addition of a pledget did not improve tension resistance.
Content-based video retrieval by example video clip
NASA Astrophysics Data System (ADS)
Dimitrova, Nevenka; Abdel-Mottaleb, Mohamed
1997-01-01
This paper presents a novel approach for video retrieval from a large archive of MPEG or Motion JPEG compressed video clips. We introduce a retrieval algorithm that takes a video clip as a query and searches the database for clips with similar contents. Video clips are characterized by a sequence of representative frame signatures, which are constructed from DC coefficients and motion information (`DC+M' signatures). The similarity between two video clips is determined by using their respective signatures. This method facilitates retrieval of clips for the purpose of video editing, broadcast news retrieval, or copyright violation detection.
Radiologic advantages of potential use of polymer plastic clips in neurosurgery.
Delibegović, Samir
2014-01-01
Plastic clips are made of diamagnetic material and may result in fewer computed tomography (CT) and magnetic resonance artifacts than titanium clips. Considering that polymer plastic clips are increasingly being used in endoscopic surgery, our study examined the CT and magnetic resonance imaging (MRI) characteristics of plastic clips after application in the neurocranium and compared them with titanium clips. Craniotomy was performed on the heads of domestic pigs (Sus scrofa domestica), and, at an angle of 90°, a permanent Yasargil FT 746 T clip was placed in a frontobasal, interhemispheric position. A plastic polymer medium-large Hem-o-lok clip was placed in the same position into another animal. After this procedure, CT of the brain was performed using Siemens 16 slice, followed by an MRI scan, on Philips MRI, 1.5 Tesla. The CT and magnetic resonance scans were analyzed. On axial CT sections through the site of placement of titanium clips, dotted hyperdensity with a high value of Hounsfield units (HUI) of about 2800-3000 could be clearly seen. At the site where the plastic polymer clips were placed, discrete hyperdensity was observed, measuring 130-140 HUI. MRI of the brain in which titanium clips were used revealed a hypointensive T1W signal in the interhemispheric fissure, with a hypointensive T2W signal. On the other hand, upon examination of the MRI of the brain in which plastic clips were used, the T1W signal described above did not occur, and there was also no T2W signal, and no artifacts observed. The plastic clips are made of a diamagnetic, nonconductive material that results in fewer CT and MRI artifacts than titanium clips. Copyright © 2014 Elsevier Inc. All rights reserved.
21 CFR 878.4320 - Removable skin clip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Removable skin clip. 878.4320 Section 878.4320...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a) Identification. A removable skin clip is a clip-like device intended to connect skin tissues temporarily to aid...
Ratings for emotion film clips.
Gabert-Quillen, Crystal A; Bartolini, Ellen E; Abravanel, Benjamin T; Sanislow, Charles A
2015-09-01
Film clips are widely utilized to elicit emotion in a variety of research studies. Normative ratings for scenes selected for these purposes support the idea that selected clips correspond to the intended target emotion, but studies reporting normative ratings are limited. Using an ethnically diverse sample of college undergraduates, selected clips were rated for intensity, discreteness, valence, and arousal. Variables hypothesized to affect the perception of stimuli (i.e., gender, race-ethnicity, and familiarity) were also examined. Our analyses generally indicated that males reacted strongly to positively valenced film clips, whereas females reacted more strongly to negatively valenced film clips. Caucasian participants tended to react more strongly to the film clips, and we found some variation by race-ethnicity across target emotions. Finally, familiarity with the films tended to produce higher ratings for positively valenced film clips, and lower ratings for negatively valenced film clips. These findings provide normative ratings for a useful set of film clips for the study of emotion, and they underscore factors to be considered in research that utilizes scenes from film for emotion elicitation.
Authoring Data-Driven Videos with DataClips.
Amini, Fereshteh; Riche, Nathalie Henry; Lee, Bongshin; Monroy-Hernandez, Andres; Irani, Pourang
2017-01-01
Data videos, or short data-driven motion graphics, are an increasingly popular medium for storytelling. However, creating data videos is difficult as it involves pulling together a unique combination of skills. We introduce DataClips, an authoring tool aimed at lowering the barriers to crafting data videos. DataClips allows non-experts to assemble data-driven "clips" together to form longer sequences. We constructed the library of data clips by analyzing the composition of over 70 data videos produced by reputable sources such as The New York Times and The Guardian. We demonstrate that DataClips can reproduce over 90% of our data videos corpus. We also report on a qualitative study comparing the authoring process and outcome achieved by (1) non-experts using DataClips, and (2) experts using Adobe Illustrator and After Effects to create data-driven clips. Results indicated that non-experts are able to learn and use DataClips with a short training period. In the span of one hour, they were able to produce more videos than experts using a professional editing tool, and their clips were rated similarly by an independent audience.
Proposal for a CLIPS software library
NASA Technical Reports Server (NTRS)
Porter, Ken
1991-01-01
This paper is a proposal to create a software library for the C Language Integrated Production System (CLIPS) expert system shell developed by NASA. Many innovative ideas for extending CLIPS were presented at the First CLIPS Users Conference, including useful user and database interfaces. CLIPS developers would benefit from a software library of reusable code. The CLIPS Users Group should establish a software library-- a course of action to make that happen is proposed. Open discussion to revise this library concept is essential, since only a group effort is likely to succeed. A response form intended to solicit opinions and support from the CLIPS community is included.
Biocompatibility of Plastic Clip in Neurocranium - Experimental Study on Dogs.
Delibegovic, Samir; Dizdarevic, Kemal; Cickusic, Elmir; Katica, Muhamed; Obhodjas, Muamer; Ocus, Muhamed
2016-01-01
A potential advantage of the use of the plastic clips in neurosurgery is their property of causing fewer artifacts than titanium clips as assessed by computed tomography and magnetic resonance scans. The biocompatibility of plastic clips was demonstrated in the peritoneal cavity, but their behavior in the neurocranium is not known. Twelve aggressive stray dogs designated for euthanasia were taken for this experimental study. The animals were divided into two groups. In all cases, after anesthesia, a craniotomy was performed, and after opening the dura, a proximal part titanium clip was placed on the isolated superficial Sylvian vein (a permanent Yasargil FT 746 T clip at a 90° angle, while a plastic Hem-o-lok clip ML was placed on another part of the vein). The first group of animals was sacrificed on the 7 < sup > th < /sup > postoperative day and the second group on the 60 < sup > th < /sup > postoperative day. Samples of tissue around the clips were taken for a histopathological evaluation. The plastic clip caused a more intensive tissue reaction than the titanium clip on the 7 < sup > th < /sup > postoperative day, but there was no statistical difference. Even on the 60 < sup > th < /sup > postoperative day there was no significant difference in tissue reaction between the titanium and plastic clips. These preliminary results confirm the possibility for the use of plastic clips in neurosurgery. Before their use in human neurosurgery, further studies are needed to investigate the long-term effects of the presence of plastic clips in the neurocranium, as well as studies of the aneurysmal model.
Fuzzy expert systems using CLIPS
NASA Technical Reports Server (NTRS)
Le, Thach C.
1994-01-01
This paper describes a CLIPS-based fuzzy expert system development environment called FCLIPS and illustrates its application to the simulated cart-pole balancing problem. FCLIPS is a straightforward extension of CLIPS without any alteration to the CLIPS internal structures. It makes use of the object-oriented and module features in CLIPS version 6.0 for the implementation of fuzzy logic concepts. Systems of varying degrees of mixed Boolean and fuzzy rules can be implemented in CLIPS. Design and implementation issues of FCLIPS will also be discussed.
Restoration of clipped seismic waveforms using projection onto convex sets method
Zhang, Jinhai; Hao, Jinlai; Zhao, Xu; Wang, Shuqin; Zhao, Lianfeng; Wang, Weimin; Yao, Zhenxing
2016-01-01
The seismic waveforms would be clipped when the amplitude exceeds the upper-limit dynamic range of seismometer. Clipped waveforms are typically assumed not useful and seldom used in waveform-based research. Here, we assume the clipped components of the waveform share the same frequency content with the un-clipped components. We leverage this similarity to convert clipped waveforms to true waveforms by iteratively reconstructing the frequency spectrum using the projection onto convex sets method. Using artificially clipped data we find that statistically the restoration error is ~1% and ~5% when clipped at 70% and 40% peak amplitude, respectively. We verify our method using real data recorded at co-located seismometers that have different gain controls, one set to record large amplitudes on scale and the other set to record low amplitudes on scale. Using our restoration method we recover 87 out of 93 clipped broadband records from the 2013 Mw6.6 Lushan earthquake. Estimating that we recover 20 clipped waveforms for each M5.0+ earthquake, so for the ~1,500 M5.0+ events that occur each year we could restore ~30,000 clipped waveforms each year, which would greatly enhance useable waveform data archives. These restored waveform data would also improve the azimuthal station coverage and spatial footprint. PMID:27966618
A systematic review of discomfort due to toe or ear clipping in laboratory rodents
Geessink, Florentine J.; Brouwer, Michelle A. E.; Tillema, Alice; Ritskes-Hoitinga, Merel
2017-01-01
Toe clipping and ear clipping (also ear notching or ear punching) are frequently used methods for individual identification of laboratory rodents. These procedures potentially cause severe discomfort, which can reduce animal welfare and distort experimental results. However, no systematic summary of the evidence on this topic currently exists. We conducted a systematic review of the evidence for discomfort due to toe or ear clipping in rodents. The review methodology was pre-specified in a registered review protocol. The population, intervention, control, outcome (PICO) question was: In rodents, what is the effect of toe clipping or ear clipping, compared with no clipping or sham clipping, on welfare-related outcomes? Through a systematic search in PubMed, Embase, Web of Science and grey literature, we identified seven studies on the effect of ear clipping on animal welfare, and five such studies on toe clipping. Studies were included in the review if they contained original data from an in vivo experiment in rodents, assessing the effect of toe clipping or ear clipping on a welfare-related outcome. Case studies and studies applying unsuitable co-interventions were excluded. Study quality was appraised using an extended version of SYstematic Review Centre for Laboratory animal Experimentation (SYRCLE)’s risk of bias tool for animal studies. Study characteristics and outcome measures were highly heterogeneous, and there was an unclear or high risk of bias in all studies. We therefore present a narrative synthesis of the evidence identified. None of the studies reported a sample size calculation. Out of over 60 different outcomes, we found evidence of discomfort due to ear clipping in the form of increased respiratory volume, vocalization and blood pressure. For toe clipping, increased vocalization and decreased motor activity in pups were found, as well as long-term effects in the form of reduced grip strength and swimming ability in adults. In conclusion, there is too little evidence to reliably assess discomfort due to toe or ear clipping, and the quality of the available evidence is uncertain. Adequately powered, high-quality studies reporting reliable, relevant outcome measures are needed to accurately assess the impact of these identification techniques. Until more reliable evidence is available, any effect of toe clipping or ear clipping on animal welfare and study results cannot be confirmed or excluded. PMID:28429644
Guo, Xue; Zhou, Xishu; Hale, Lauren; Yuan, Mengting; Feng, Jiajie; Ning, Daliang; Shi, Zhou; Qin, Yujia; Liu, Feifei; Wu, Liyou; He, Zhili; Van Nostrand, Joy D.; Liu, Xueduan; Luo, Yiqi; Tiedje, James M.; Zhou, Jizhong
2018-01-01
Clipping, removal of aboveground plant biomass, is an important issue in grassland ecology. However, few studies have focused on the effect of clipping on belowground microbial communities. Using integrated metagenomic technologies, we examined the taxonomic and functional responses of soil microbial communities to annual clipping (2010–2014) in a grassland ecosystem of the Great Plains of North America. Our results indicated that clipping significantly (P < 0.05) increased root and microbial respiration rates. Annual temporal variation within the microbial communities was much greater than the significant changes introduced by clipping, but cumulative effects of clipping were still observed in the long-term scale. The abundances of some bacterial and fungal lineages including Actinobacteria and Bacteroidetes were significantly (P < 0.05) changed by clipping. Clipping significantly (P < 0.05) increased the abundances of labile carbon (C) degrading genes. More importantly, the abundances of recalcitrant C degrading genes were consistently and significantly (P < 0.05) increased by clipping in the last 2 years, which could accelerate recalcitrant C degradation and weaken long-term soil carbon stability. Furthermore, genes involved in nutrient-cycling processes including nitrogen cycling and phosphorus utilization were also significantly increased by clipping. The shifts of microbial communities were significantly correlated with soil respiration and plant productivity. Intriguingly, clipping effects on microbial function may be highly regulated by precipitation at the interannual scale. Altogether, our results illustrated the potential of soil microbial communities for increased soil organic matter decomposition under clipping land-use practices. PMID:29904372
It is time for a better clip applier - 3 mm, percutaneous, non-crushing and locking.
Yuval, Jonathan B; Weiss, Daniel J; Paz, Adrian; Bachar, Yehuda; Brodie, Ronit; Shapira, Yinon; Mintz, Yoav
2017-10-06
Since the advent of laparoscopy there have been attempts to minimize abdominal wall incisions. For this purpose smaller instruments have been produced. Our aim was to develop the first 3 mm percutaneous clip applier and to make it better than the standard clips of today. The ClipTip clip is made of Nitinol and has a crocodile shaped jaws, which when apposed effectively seal vessels. The shaft operates as a retractable needle permitting percutaneous insertion. Closing, reopening and reclosing is possible. The physical properties of the device were compared to three commercially available clip appliers. Surgeries were performed on porcine animals by experienced surgeons. In comparison to available clips, the superiority of the ClipTip is a combination of wide effective length alongside the ability to withstand strong forces. In live animal studies the Cliptip was inserted into the peritoneal cavity without any injuries. Vessels were ligated successfully and no clip dislodgement or leakage occurred. We developed the next generation clip applier with better properties. Advantages include its length, the needleoscopic caliber, non-crushing effect, locking mechanism and wide aperture. The device has performed safely and effectively in pre-clinical tests. Further studies are planned in humans.
Persistence in and Release of 2,4-D and Azoxystrobin from Turfgrass Clippings.
Jeffries, Matthew D; Yelverton, Fred H; Ahmed, Khalied A; Gannon, Travis W
2016-11-01
Research has shown that pesticide residue in clippings from previously treated turfgrass may become bioavailable as grass decomposes, adversely affecting off-target organisms. We conducted a field study to quantify 2,4-D (2,4-dichlorophenoxyacetic acid) and azoxystrobin (methyl(E)-2-{2[6-(2-cyanophenoxy)pyrmidin-4-yloxy]phenyl}-3-methoxyacrylate) residues in turfgrass clippings collected from hybrid bermudagrass [ (L.) Pers. × Burtt-Davy], tall fescue [ (Schreb.) S.J. Darbyshire], and zoysiagrass ( Steud.). A subsequent greenhouse experiment was conducted to measure pesticide release from clippings into water. 2,4-D (1.6 kg a.i. ha) and azoxystrobin (0.6 kg a.i. ha) were applied to field plots at 32, 16, 8, 4, 2, 1, or 0 d before collection of the clippings. Clippings were collected from each experimental unit to quantify pesticide release from clippings into water. Both 2,4-D and azoxystrobin were detected when turfgrass was treated over the 32-d experimental period, suggesting that clipping management should be implemented for an extended period of time after application. Pesticide residue was detected in all water samples collected, confirming 2,4-D and azoxystrobin release from turfgrass clippings; however, pesticide release varied between compounds. Two days after clippings were incorporated in water, 39 and 10% of 2,4-D and azoxystrobin were released from clippings, respectively. Our research supports the currently recommended practice of returning clippings to the turfgrass stand when mowing because removal of 2,4-D and azoxystrobin in clippings may reduce pest control and cause adverse off-target impacts. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Ota, Nakao; Tanikawa, Rokuya; Noda, Kosumo; Tsuboi, Toshiyuki; Kamiyama, Hiroyasu; Tokuda, Sadahisa
2015-01-01
Background: The fenestrated clip is sometimes useful in limited approach angle and narrow working space. However, before the development of the new Yasargil titanium fenestrated mini-clip, the only variations of fenestrated clips were those of larger sizes. And those larger clips have a problem of the triangle-shaped gap at the proximal end of the blade. The authors describe the efficiency, limitations and surgical technique of using the Yasargil titanium fenestrated mini-clip. Methods: Fifty-nine cases of aneurysms were treated using these mini-clips. Aneurysm location, size and dome neck ratio, mean follow-up period, neck remnant, and recurrence rate were also analyzed. Among these cases, we present eight characteristic cases, including a case with aneurysm recurrence, and we review the problems associated with the triangle-shaped gap at the proximal end of the clip. Results: The average size of the aneurysms was 5.57 mm, and the dome neck ratio was >2.0 in 1.69%, >1.5 in 11.8%, >1.2 in 35.6%, and <1.2 in 50.8% of cases. The mean follow-up period for the 59 cases was 5.5 months (range, 0.5–16 months). Angiographic recurrence of the treated portion occurred in 1 case (1.7%), including an aneurysm in the basilar artery tip aneurysm. Conclusion: The availability of the Yasargil titanium fenestrated mini-clip increases the options for clipping to minimize the remnant of the clipped aneurysm. However, there is still concern over the triangular space at the base of the blade, especially when treating an aneurysm with a thin vessel wall. Therefore, modification of the clipping technique is sometimes needed. PMID:26664871
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santvoort, J van; Van der Drift, M; Kuipers, J
2014-06-01
Purpose: To find out whether tantalum surgical clips can be used for online position verification in treatment of the lumpectomy cavity (LC) in breast cancer patients. Tantalum is a high density metal that could be visible on Electronic Portal Images (EPIs) and be an affordable alternative to gold markers. Clips are considered more representative for the LC position than nearby bony structures. Methods: In twelve patients the surgeon had placed 2 to 5 tantalum clips in the LC. The AP and lateral fields used for portal imaging, were adapted. In doing so, both bony structures and tantalum clips were visiblemore » on EPIs. The following analyses were performed:1. Image degradation, with respect to delineating the CTV, of the axial CT slices by artefacts because of the tantalum clips was evaluated by a radiation oncologist;2. The visibility of the tantalum clips on the EPIs was evaluated by four radiation therapists (RTTs);3. Bony anatomy and tantalum clip matches were performed on the same images independently by two observers. Results: 1. Delineation of the CTV by the radiation oncologist was not hampered by CT image artefacts because of the clips.2. The mean score for visibility of the clips on the EPIs, analysed by the four RTTs, was 5.6 on a scale of 10 (range 3.9 – 8.0).3. In total 12 patients with 16 fractions each were analysed. The differences between clip match and bone match are significant with a mean vector length of 5.2 mm (SD 1.9 mm) for the difference. Conclusion: Results of matches on tantalum clips as compared to matches on bony structures differ substantially. Therefore clip matches can result in smaller CTV to PTV margins than bone matches. Visibility of the clips on EPIs is sufficient, so they can be an alternative to gold markers.« less
Hulka, J F; Omran, K; Lieberman, B A; Gordon, A G
1979-12-15
Since the original spring clip sterilization studies were reported, a number of clinically important modifications to the spring clip and applicator have been developed. The spring-loaded clip, manufactured by Richard Wolf Medical Instruments Corporation of Chicago, Illinois, and Rocket of London, Inc., London, England, and New York, New York can be applied with either a one- or two-incision applicator and the clips and applicators currently available incorporate improvements to the original prototypes in design, manufacture, and quality control. The two-incision applicator is associated with significantly fewer misapplications and the high pregnancy rates reported with the original clip and applicator have not occurred with the current designs. Comparative studies between the clip and band have revealed less operative bleeding and pain associated with the clip. The method is appropriate to all women requesting sterilization but especially to those in the younger age group who may subsequently request reversal because of divorce and remarriage.
An object oriented extension to CLIPS
NASA Technical Reports Server (NTRS)
Sobkowicz, Clifford
1990-01-01
A presentation of software sub-system developed to augment C Language Production Systems (CLIPS) with facilities for object oriented Knowledge representation. Functions are provided to define classes, instantiate objects, access attributes, and assert object related facts. This extension is implemented via the CLIPS user function interface and does not require modification of any CLIPS code. It does rely on internal CLIPS functions for memory management and symbol representation.
Ito, Kiyoshi; Aoyama, Tatsuro; Horiuchi, Tetsuyoshi; Hongo, Kazuhiro
2015-12-01
The nonpenetrating titanium clip has been successfully used in peripheral arterial bypass surgery. The purpose of this study was to evaluate the leakage pressures and patterns of nonpenetrating titanium clips using a simple model that mimicked spinal surgery. In addition, the authors describe their surgical experience with these clips and the follow-up results in 31 consecutive patients. The authors compared nonpenetrating titanium clips and expanded polytetrafluoroethylene (ePTFE) sutures in relation to the water pressure that could be tolerated by sutured ePTFE sheets, and the leakage pressure patterns were determined. The changes in leakage pressures at 5 minutes, 30 minutes, and 12 hours were examined when the clips and sutures were used in combination with the mesh-and-glue technique in an in vitro study. Thirty-one patients underwent spinal intradural procedures using nonpenetrating titanium clips to suture the dura maters using the meshand-glue technique, involving fibrin glue and polyglycolic acid-fibrin sheets. A significant difference was apparent between the ePTFE suture group and the nonpenetrating titanium clip group, with the latter showing a leakage pressure that could be sustained and was 1508% higher than that of the former (p = 0.001). In relation to leakage patterns, the nonpenetrating titanium clips did not make any suture holes in the ePTFE sheet and fluid leakage occurred between the clips, whereas fluid leakage was associated with the pressure elevation that occurred at the suture holes made by the ePTFE sutures. Of the 31 patients who underwent spinal intradural procedures using nonpenetrating titanium clips, 1 (3.2%) experienced cerebrospinal fluid (CSF) leakage postoperatively. No other complications-for example, allergic reactions, adhesions, or infections--were encountered. The interrupted placement of nonpenetrating titanium clips enables dural closure without creating any holes. These clips facilitate improvements in the initial leakage pressure and reduce postoperative CSF leakage following spinal surgery. The authors conclude that it is very beneficial to suture the spinal dura mater using nonpenetrating titanium clips given the anatomical characteristics of the spinal dura mater and the fact that the clips do not create suture holes.
Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum
Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.
Using CLIPS as the cornerstone of a graduate expert systems course
NASA Technical Reports Server (NTRS)
Yue, Kwok-Bun
1991-01-01
The effective use of the C Language Integrated Production System (CLIPS) as a cornerstone in a graduate expert systems course is described. The course include 8 or 9 hours of in-depth lecturing in CLIPS, as well as a broad coverage of major topics and techniques in expert systems. As part of the requirements of the course, students solved two small yet non-trival problems in CLIPS before going on to develop a toy expert system in CLIPS in an incremental manner as the term project. Furthermore, students were required to evaluate CLIPS programs written by their classmates. An anonymous questionnaire at the end of the semester revealed that the students responded very favorably to the course, especially their experience with CLIPS.
Third CLIPS Conference Proceedings, volume 2
NASA Technical Reports Server (NTRS)
Riley, Gary (Editor)
1994-01-01
Expert systems are computer programs which emulate human expertise in well defined problem domains. The C Language Integrated Production System (CLIPS) is an expert system building tool, developed at the Johnson Space Center, which provides a complete environment for the development and delivery of rule and/or object based expert systems. CLIPS was specifically designed to provide a low cost option for developing and deploying expert system applications across a wide range of hardware platforms. The development of CLIPS has helped to improve the ability to deliver expert system technology throughout the public and private sectors for a wide range of applications and diverse computing environments. The Third Conference on CLIPS provided a forum for CLIPS users to present and discuss papers relating to CLIPS applications, uses, and extensions.
MIRO: A debugging tool for CLIPS incorporating historical Rete networks
NASA Technical Reports Server (NTRS)
Tuttle, Sharon M.; Eick, Christoph F.
1994-01-01
At the last CLIPS conference, we discussed our ideas for adding a temporal dimension to the Rete network used to implement CLIPS. The resulting historical Rete network could then be used to store 'historical' information about a run of a CLIPS program, to aid in debugging. MIRO, a debugging tool for CLIPS built on top of CLIPS, incorporates such a historical Rete network and uses it to support its prototype question-answering capability. By enabling CLIPS users to directly ask debugging-related questions about the history of a program run, we hope to reduce the amount of single-stepping and program tracing required to debug a CLIPS program. In this paper, we briefly describe MIRO's architecture and implementation, and the current question-types that MIRO supports. These question-types are further illustrated using an example, and the benefits of the debugging tool are discussed. We also present empirical results that measure the run-time and partial storage overhead of MIRO, and discuss how MIRO may also be used to study various efficiency aspects of CLIPS programs.
The disappearing clip: an unusual complication in MRI biopsy
Bourke, Anita Geraldine; Peter, Prasant; Jose, Chaitra Lesli
2014-01-01
MRI-guided biopsies are being increasingly used for otherwise occult breast lesions. Clip migration has been reported however, to the best of our knowledge, there have been no documented cases of entire disappearance of a marker clip. Absence of the postbiopsy marker clip was noted when our patient returned for preoperative hook-wire localisation even though accurate clip placement had been confirmed on the post-MRI biopsy mammogram. PMID:25139917
Using film clips to enhance nursing education.
Herrman, Judith W
2006-01-01
Film clips in nursing education provide a unique way to promote active learning. Several methods for using film clips and combining them with other teaching strategies are discussed. Suggestions for the use of popular clips, logistical aspects of showing clips in class, and legal issues associated with copyright are addressed. Faculty are encouraged to use this strategy to evoke emotional responses, generate discussion, enhance clinical decision making, and provide vicarious learning.
Doss, Vinodh T.; Goyal, Nitin; Humphries, William; Hoit, Dan; Arthur, Adam; Elijovich, Lucas
2015-01-01
Background Residual aneurysm after microsurgical clipping carries a risk of aneurysm growth and rupture. Digital subtraction angiography (DSA) remains the standard to determine the adequacy of clipping. Intraoperative indocyanine green (ICG) angiography is increasingly utilized to confirm optimal clip positioning across the neck and to evaluate the adjacent vasculature. Objective We evaluated the correlation between ICG and DSA in clipped intracranial aneurysms. Methods A retrospective study of patients who underwent craniotomy and microsurgical clipping of intracranial aneurysms with ICG for 2 years. Patient characteristics, presentation details, operative reports, and pre- and postclipping angiographic images were reviewed to determine the adequacy of the clipping. Results Forty-seven patients underwent clipping with ICG and postoperative DSA: 57 aneurysms were clipped; 23 patients (48.9%) presented with subarachnoid hemorrhage. Nine aneurysms demonstrated a residual on DSA not identified on ICG (residual sizes ranged from 0.5 to 4.3 mm; average size: 1.8 mm). Postoperative DSA demonstrated no branch occlusions. Conclusion Intraoperative ICG is useful in the clipping of intracranial aneurysms to ensure a gross patency of branch vessels; however, the presence of residual aneurysms and subtle changes in flow in branch vessels is best seen by DSA. This has important clinical implications with regard to follow-up imaging and surgical/endovascular management. PMID:26279659
Maffei, Antonio; Vencato, Valentina; Angrilli, Alessandro
2015-01-01
The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives.
Recurrence of ICA-PCoA aneurysms after neck clipping.
Sakaki, T; Takeshima, T; Tominaga, M; Hashimoto, H; Kawaguchi, S
1994-01-01
Between 1975 and 1992, 2211 patients underwent aneurysmal neck clipping at the Nara Medical University clinic and associated hospitals. The aneurysm in 931 of these patients was situated at the junction of the internal carotid artery (ICA) and posterior communicating artery (PCoA). Seven patients were readmitted 4 to 17 years after the first surgery because of regrowth and rupture of an ICA-PCoA aneurysmal sac that had arisen from the residual neck. On angiograms obtained following aneurysmal neck clipping, a large primitive type of PCoA was demonstrated in six patients and a small PCoA in one. A small residual aneurysm was confirmed in only two patients and angiographically complete neck clipping in five. Recurrent ICA-PCoA aneurysms were separated into two types based on the position of the old clip in relation to the new growth. Type 1 aneurysms regrow from the entire neck and balloon eccentrically. In this type, it is possible to apply the clip at the neck as in conventional clipping for a ruptured aneurysm. Type 2 includes aneurysms in which the proximal portion of a previous clip is situated at the corner of the ICA and aneurysmal neck and the distal portion on the enlarged dome of the aneurysm, because the sac is regrowing from a portion of the residual neck. In this type of aneurysm, a Sugita fenestrated clip can occlude the residual neck, overriding the old clip. Classifying these aneurysms into two groups is very useful from a surgical point of view because it is possible to apply a new clip without removing the old clip, which was found to be adherent to surrounding tissue.
Automated revision of CLIPS rule-bases
NASA Technical Reports Server (NTRS)
Murphy, Patrick M.; Pazzani, Michael J.
1994-01-01
This paper describes CLIPS-R, a theory revision system for the revision of CLIPS rule-bases. CLIPS-R may be used for a variety of knowledge-base revision tasks, such as refining a prototype system, adapting an existing system to slightly different operating conditions, or improving an operational system that makes occasional errors. We present a description of how CLIPS-R revises rule-bases, and an evaluation of the system on three rule-bases.
CLIPS: A proposal for improved usability
NASA Technical Reports Server (NTRS)
Patton, Charles R.
1990-01-01
This paper proposes the enhancement of the CLIPS user interface to improve the over-all usability of the CLIPS development environment. It suggests some directions for the long term growth of the user interface, and discusses some specific strengths and weaknesses of the current CLIPS PC user interface. Every user of CLIPS shares a common experience: his/her first interaction with the system itself. As with any new language, between the process of installing CLIPS on the appropriate computer and the completion of a large application, an intensive learning process takes place. For those with extensive programming knowledge and LISP backgrounds, this experience may have been mostly interesting and pleasant. Being familiar with products that are similar to CLIPS in many ways, these users enjoy a relatively short training period with the product. Already familiar with many of the functions they wish to employ, experienced users are free to focus on the capabilities of CLIPS that make it uniquely useful within their working environment.
Seismic signals hard clipping overcoming
NASA Astrophysics Data System (ADS)
Olszowa, Paula; Sokolowski, Jakub
2018-01-01
In signal processing the clipping is understand as the phenomenon of limiting the signal beyond certain threshold. It is often related to overloading of a sensor. Two particular types of clipping are being recognized: soft and hard. Beyond the limiting value soft clipping reduces the signal real gain while the hard clipping stiffly sets the signal values at the limit. In both cases certain amount of signal information is lost. Obviously if one possess the model which describes the considered signal and the threshold value (which might be slightly more difficult to obtain in the soft clipping case), the attempt of restoring the signal can be made. Commonly it is assumed that the seismic signals take form of an impulse response of some specific system. This may lead to belief that the sine wave may be the most appropriate to fit in the clipping period. However, this should be tested. In this paper the possibility of overcoming the hard clipping in seismic signals originating from a geoseismic station belonging to an underground mine is considered. A set of raw signals will be hard-clipped manually and then couple different functions will be fitted and compared in terms of least squares. The results will be then analysed.
CLIPS: The C language integrated production system
NASA Technical Reports Server (NTRS)
Riley, Gary
1994-01-01
Expert systems are computer programs which emulate human expertise in well defined problem domains. The potential payoff from expert systems is high: valuable expertise can be captured and preserved, repetitive and/or mundane tasks requiring human expertise can be automated, and uniformity can be applied in decision making processes. The C Language Integrated Production System (CLIPS) is an expert system building tool, developed at the Johnson Space Center, which provides a complete environment for the development and delivery of rule and/or object based expert systems. CLIPS was specifically designed to provide a low cost option for developing and deploying expert system applications across a wide range of hardware platforms. The commercial potential of CLIPS is vast. Currently, CLIPS is being used by over 5,000 individuals throughout the public and private sector. Because the CLIPS source code is readily available, numerous groups have used CLIPS as the basis for their own expert system tools. To date, three commercially available tools have been derived from CLIPS. In general, the development of CLIPS has helped to improve the ability to deliver expert system technology throughout the public and private sectors for a wide range of applications and diverse computing environments.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-06
... order are plastic and vinyl covered paper clips, butterfly clips, binder clips, or other paper fasteners... order is revoked. Parties can obtain a public copy of the I&D Memo from the Central Records Unit, room...
Annual Removal of Aboveground Plant Biomass Alters Soil Microbial Responses to Warming
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xue, Kai; Yuan, Mengting M.; Xie, Jianping
Clipping (i.e., harvesting aboveground plant biomass) is common in agriculture and for bioenergy production. However, microbial responses to clipping in the context of climate warming are poorly understood. We investigated the interactive effects of grassland warming and clipping on soil properties and plant and microbial communities, in particular, on microbial functional genes. Clipping alone did not change the plant biomass production, but warming and clipping combined increased the C4 peak biomass by 47% and belowground net primary production by 110%. Clipping alone and in combination with warming decreased the soil carbon input from litter by 81% and 75%, respectively. Withmore » less carbon input, the abundances of genes involved in degrading relatively recalcitrant carbon increased by 38% to 137% in response to either clipping or the combined treatment, which could weaken long-term soil carbon stability and trigger positive feedback with respect to warming. Clipping alone also increased the abundance of genes for nitrogen fixation, mineralization, and denitrification by 32% to 39%. Such potentially stimulated nitrogen fixation could help compensate for the 20% decline in soil ammonium levels caused by clipping alone and could contribute to unchanged plant biomass levels. Moreover, clipping tended to interact antagonistically with warming, especially with respect to effects on nitrogen cycling genes, demonstrating that single-factor studies cannot predict multifactorial changes. These results revealed that clipping alone or in combination with warming altered soil and plant properties as well as the abundance and structure of soil microbial functional genes. Aboveground biomass removal for biofuel production needs to be reconsidered, as the long-term soil carbon stability may be weakened. IMPORTANCE Global change involves simultaneous alterations, including those caused by climate warming and land management practices (e.g., clipping). Data on the interactive effects of warming and clipping on ecosystems remain elusive, particularly in microbial ecology. This study found that clipping alters microbial responses to warming and demonstrated the effects of antagonistic interactions between clipping and warming on microbial functional genes. Clipping alone or combined with warming enriched genes degrading relatively recalcitrant carbon, likely reflecting the decreased quantity of soil carbon input from litter, which could weaken long-term soil C stability and trigger positive warming feedback. These results have important implications in assessing and predicting the consequences of global climate change and indicate that the removal of aboveground biomass for biofuel production may need to be reconsidered.« less
Annual Removal of Aboveground Plant Biomass Alters Soil Microbial Responses to Warming
Xue, Kai; Yuan, Mengting M.; Xie, Jianping; ...
2016-09-27
Clipping (i.e., harvesting aboveground plant biomass) is common in agriculture and for bioenergy production. However, microbial responses to clipping in the context of climate warming are poorly understood. We investigated the interactive effects of grassland warming and clipping on soil properties and plant and microbial communities, in particular, on microbial functional genes. Clipping alone did not change the plant biomass production, but warming and clipping combined increased the C4 peak biomass by 47% and belowground net primary production by 110%. Clipping alone and in combination with warming decreased the soil carbon input from litter by 81% and 75%, respectively. Withmore » less carbon input, the abundances of genes involved in degrading relatively recalcitrant carbon increased by 38% to 137% in response to either clipping or the combined treatment, which could weaken long-term soil carbon stability and trigger positive feedback with respect to warming. Clipping alone also increased the abundance of genes for nitrogen fixation, mineralization, and denitrification by 32% to 39%. Such potentially stimulated nitrogen fixation could help compensate for the 20% decline in soil ammonium levels caused by clipping alone and could contribute to unchanged plant biomass levels. Moreover, clipping tended to interact antagonistically with warming, especially with respect to effects on nitrogen cycling genes, demonstrating that single-factor studies cannot predict multifactorial changes. These results revealed that clipping alone or in combination with warming altered soil and plant properties as well as the abundance and structure of soil microbial functional genes. Aboveground biomass removal for biofuel production needs to be reconsidered, as the long-term soil carbon stability may be weakened. IMPORTANCE Global change involves simultaneous alterations, including those caused by climate warming and land management practices (e.g., clipping). Data on the interactive effects of warming and clipping on ecosystems remain elusive, particularly in microbial ecology. This study found that clipping alters microbial responses to warming and demonstrated the effects of antagonistic interactions between clipping and warming on microbial functional genes. Clipping alone or combined with warming enriched genes degrading relatively recalcitrant carbon, likely reflecting the decreased quantity of soil carbon input from litter, which could weaken long-term soil C stability and trigger positive warming feedback. These results have important implications in assessing and predicting the consequences of global climate change and indicate that the removal of aboveground biomass for biofuel production may need to be reconsidered.« less
Cho, Won-Sang; Kim, Jeong Eun; Kang, Hyun-Seung; Ha, Eun Jin; Jung, Minwoong; Lee, Choonghee; Shin, Il Hyung; Kang, Uk
2017-04-01
Neuroendoscopy is useful for assessing status of perforators, parent arteries, and aneurysms beyond the straight line of microscopic view during aneurysm clipping. We aimed to evaluate the clinical usefulness of our endoscopic indocyanine green angiography (ICGA) system, which can simultaneously display visible light and indocyanine green fluorescent images. Surgical clipping of 16 unruptured aneurysms in 10 patients was performed via the keyhole approach. Using our endoscopic ICGA and commercial microscopic ICGA systems, we prospectively compared 10 targeted cerebral aneurysms at the posterior communicating (n = 4) and anterior choroidal (n = 6) arteries. Microscopic ICGA and endoscopic ICGA were feasible during surgery. Microscopic ICGA displayed 50% of branch orifices, 100% of branch trunks, and 20% of exact clip positions, whereas endoscopic ICGA showed 100% of these. Based on endoscopic ICGA findings such as incomplete clipping and compromise of parent arteries or branches, clips were repositioned in 2 cases, and additional clips were applied in 2 cases. Complete occlusion and residual neck states were achieved in 6 and 4 aneurysms after surgery. There were no neurologic deficits within 3 months after surgery except for frontalis palsy and anosmia in each patient. The endoscopic ICGA system with dual imaging of visible light and indocyanine green fluorescence was very useful for assessing geometry of aneurysms and surrounding vessels before clipping and for evaluating completeness of clip position after clipping. Copyright © 2017 Elsevier Inc. All rights reserved.
Neural correlates of emotional regulation while viewing films.
Shimamura, Arthur P; Marian, Diane E; Haskins, Andrew L
2013-03-01
Negative and arousal-inducing film clips were used to assess the neural correlates of emotional expression and suppression. Compared to viewing neutral clips, both negative (disgusting) and arousal (action) clips activated primarily posterior regions in the parietal and occipital cortex when participants were instructed to express their emotions. When instructed to suppress their emotions while viewing negative clips, a broad frontoparietal network was activated that included lateral, medial, and orbital regions in the prefrontal cortex as well as lateral and medial regions of the posterior parietal cortex. The suppression of arousal clips also activated prefrontal and parietal regions, though not to the same extent as the suppression of negative clips. The findings demonstrate the potency of using movies to engage emotional processes and highlight a broad frontoparietal network that is engaged during the suppression of negative film clips.
IDENTIFICATION BADGE WITH DETACHABLE CLIP
Burns, M.T.
1962-09-18
The clip has a long slot with a round enlarged end, flat on one side. The badge has a headed member that is circular except for a flat side. The badge is connected to, or disconnected from, the clip by insertion of the headed member through the enlarged end of the slot in the clip. The badge is unlikely to be accidentally disconnected from the clip while being worn on a worker's clothing, because the weight of the badge keeps the headed member away from the enlarged end of the slot in the clip, and the headed member can pass through the enlarged end of the slot only at one relative angular position between badge and clip, namely, that angle at which the flat side of the headed member is coincident with the flat side of the enlarged end of the slot. (AEC)
A data acquisition system for coincidence imaging using a conventional dual head gamma camera
NASA Astrophysics Data System (ADS)
Lewellen, T. K.; Miyaoka, R. S.; Jansen, F.; Kaplan, M. S.
1997-06-01
A low cost data acquisition system (DAS) was developed to acquire coincidence data from an unmodified General Electric Maxxus dual head scintillation camera. A high impedance pick-off circuit provides position and energy signals to the DAS without interfering with normal camera operation. The signals are pulse-clipped to reduce pileup effects. Coincidence is determined with fast timing signals derived from constant fraction discriminators. A charge-integrating FERA 16 channel ADC feeds position and energy data to two CAMAC FERA memories operated as ping-pong buffers. A Macintosh PowerPC running Labview controls the system and reads the CAMAC memories. A CAMAC 12-channel scaler records singles and coincidence rate data. The system dead-time is approximately 10% at a coincidence rate of 4.0 kHz.
Maffei, Antonio; Vencato, Valentina; Angrilli, Alessandro
2015-01-01
The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives. PMID:26717488
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip rack. 882.4215 Section 882.4215 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4215 Clip rack. (a) Identification. A clip rack is a...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Scalp clip. 882.4150 Section 882.4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4150 Scalp clip. (a) Identification. A scalp clip is a...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Scalp clip. 882.4150 Section 882.4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4150 Scalp clip. (a) Identification. A scalp clip is a...
21 CFR 886.1410 - Ophthalmic trial lens clip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip rack. 882.4215 Section 882.4215 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4215 Clip rack. (a) Identification. A clip rack is a...
21 CFR 882.4175 - Aneurysm clip applier.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a) Identification. An aneurysm clip applier is a device used by the surgeon for holding and applying intracranial...
21 CFR 882.5200 - Aneurysm clip.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and... NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm clip is a device used to occlude an intracranial aneurysm (a balloonlike sac formed on a blood vessel...
21 CFR 882.4175 - Aneurysm clip applier.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a) Identification. An aneurysm clip applier is a device used by the surgeon for holding and applying intracranial...
21 CFR 882.5200 - Aneurysm clip.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and... NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm clip is a device used to occlude an intracranial aneurysm (a balloonlike sac formed on a blood vessel...
21 CFR 882.5200 - Aneurysm clip.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and... NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm clip is a device used to occlude an intracranial aneurysm (a balloonlike sac formed on a blood vessel...
21 CFR 882.4175 - Aneurysm clip applier.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a) Identification. An aneurysm clip applier is a device used by the surgeon for holding and applying intracranial...
Vasilenko, Yu V; Kim, A I; Kotov, S A
2002-11-01
The mechanism of extravasal occlusion of blood vessels with titanic clips "Atrauclip" and "Ligaclip extra" was studied in order to reveal indications and contraindications to their use. Occlusion with the clips of both types was ineffective in vessels with a diameter of >7.0 mm. Arteritis or the presence of an intravascular occlusion facility in the vessel were also the contraindications for clip occlusion. In overcases the procedure of occlusion with titanic clips was efficient and atraumatic.
Influences of emotion on context memory while viewing film clips.
Anderson, Lisa; Shimamura, Arthur P
2005-01-01
Participants listened to words while viewing film clips (audio off). Film clips were classified as neutral, positively valenced, negatively valenced, and arousing. Memory was assessed in three ways: recall of film content, recall of words, and context recognition. In the context recognition test, participants were presented a word and determined which film clip was showing when the word was originally presented. In two experiments, context memory performance was disrupted when words were presented during negatively valenced film clips, whereas it was enhanced when words were presented during arousing film clips. Free recall of words presented during the negatively valenced films was also disrupted. These findings suggest multiple influences of emotion on memory performance.
Tricuspid Clip: Step-by-Step and Clinical Data.
Tang, Gilbert H L
2018-01-01
Symptomatic severe tricuspid regurgitation (TR), if untreated, carries a dismal prognosis. These patients are at very high risk for surgical repair or replacement and transcatheter options to treat TR are emerging. More than 300 transcatheter tricuspid repairs with the MitraClip system have been performed worldwide with promising results. The TriClip system, with the MitraClip NT delivered via a dedicated tricuspid steerable guide catheter, is currently under investigation. This article describes the step-by-step technique on using the MitraClip system to perform transcatheter tricuspid repair using echocardiographic and fluoroscopic guidance. The latest data on worldwide experience with tricuspid clipping are also discussed. Copyright © 2017 Elsevier Inc. All rights reserved.
21 CFR 884.2685 - Fetal scalp clip electrode and applicator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal scalp clip electrode and applicator. 884...
21 CFR 884.2685 - Fetal scalp clip electrode and applicator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal scalp clip electrode and applicator. 884...
21 CFR 884.2685 - Fetal scalp clip electrode and applicator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal scalp clip electrode and applicator. 884...
21 CFR 884.2685 - Fetal scalp clip electrode and applicator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal scalp clip electrode and applicator. 884...
21 CFR 884.2685 - Fetal scalp clip electrode and applicator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal scalp clip electrode and applicator. 884...
The Effects of Multimodality through Storytelling Using Various Movie Clips
ERIC Educational Resources Information Center
Kim, SoHee
2016-01-01
This study examines the salient multimodal approaches for communicative competence and learners' reactions through storytelling tasks with three different modes: a silent movie clip, a movie clip with only sound effects, and a movie clip with sound effects and dialogue. In order to measure different multimodal effects and to define better delivery…
Kothari, L K; Gupta, A S
1978-02-01
In 15 human subjects, the vasa deferentia were occluded by applying two tantalum clips on one side and by conventional vasectomy with silk ligatures on the other. After 2 weeks, the occluded segments were recovered for histopathologic examination of serial sections. Obstructing the seminal tract did not, as such, produce any significant change in the vas: the distal and proximal segments appeared to be essentially similar and normal. At the actual site of occlusion, however, tantalum clips produced marked flattening of the tube, complete loss of lining epithelium, distortion of the muscular lamellae, and areas of hemorrhage. The lumen was converted into a narrow slit. Under the ligatures, the damage was largely confined to denudation of the mucosal epithelium. The mucosa of the intersegment left unexcised between two clips showed hyalinization, invasion by macrophages, and degeneration of the epithelium. The changes under the clips suggest that, although clip occlusion may offer several advantages, sterility cannot be reversed merely by removing the clips. The mechanisms of these changes, different in the case of clips and ligatures, are discussed and some possible long-term consequences are considered.
Application of Micromirror in Microsurgical Clipping to the Intracranial Aneurysms.
Zhao, Chao; Ma, Zhiguo; Zhang, Yuhai; Mou, Shanling; Yang, Yunxue; Yang, Yonglin; Sun, Guoqing; Yao, Weicheng
2018-05-01
The aim of the study was to explore the values and disadvantages of micromirror in the intracranial aneurysm clipping surgery. Micromirror was used to assist microsurgical clipping to 36 intracranial aneurysms in 31 patients, of which 3 were carotid-ophthalmic artery aneurysms, 3 were anterior choroidal artery aneurysms, 11 were posterior communicating artery aneurysms, 7 were middle cerebral artery aneurysms, 10 were anterior communicating artery or anterior cerebral artery aneurysms, and the rest were a posterior cerebral artery aneurysm and a posterior inferior cerebellar artery aneurysm. The micromirror was used before and after clipping to observe the anatomic features of necks hidden behind and medial to aneurysms, to visualize surrounding neurovascular structures, and to verify the optimal clipping position. Intraoperative indocyanine green fluorescein angiography, postoperative computerized tomography angiography, and digital subtraction angiography confirmed the success of sufficient clipping. Intraoperative indocyanine green angiography, postoperative computerized tomography angiography , or digital subtraction angiography were performed and showed no case of wrong or insufficient clipping of aneurysm. Micromirror-assisted microsurgical clipping to the intracranial aneurysm is safe, sufficient, convenient, and practical.
Narayan, Edward J; Molinia, Frank C; Kindermann, Christina; Cockrem, John F; Hero, Jean-Marc
2011-11-01
Toe-clipping, the removal of one or more toes, is a common method used to individually mark free-living animals. Whilst this method is widely used in studies of amphibians, the appropriateness of the method, and its potential detrimental effects have been the subject of debate. Here, we provide for the first time, evidence that toe-clipping is a stressor in a wild amphibian. We measured urinary corticosterone responses of male cane toads (Rhinella marina) to capture and handling only, and to toe-clipping under field conditions. Urinary testosterone concentrations and white blood cell proportions were also measured. Urinary corticosterone metabolite concentrations increased 6h after capture and handling only and remained high for 24h; corticosterone returned to baseline levels after 48 h and remained low at 72 h post capture and handling. Corticosterone concentrations in toads subjected to toe-clipping increased at 6h to significantly higher concentrations than after capture and handling only, then decreased more slowly than after capture and handling, and were still elevated (approximately double basal level) 72 h after toe-clipping. Testosterone did not change significantly after capture and handling only, whereas after toe-clipping testosterone decreased at 6h and remained low at 72 h. There were weak short-term effects of toe-clipping compared with capture and handling only on white blood cell proportions. We have clearly shown that toe-clipping is a distinctly stronger stressor than capture and handling alone. This indicates that there is an ethical cost of toe-clipping, and this should be considered when planning studies of amphibians. Copyright © 2011 Elsevier Inc. All rights reserved.
Zachenhofer, Iris; Cejna, Manfred; Schuster, Antonius; Donat, Markus; Roessler, Karl
2010-06-01
Computed tomography angiography (CTA) is a time and cost saving investigation for postoperative evaluation of clipped cerebral aneurysm patients. A retrospective study was conducted to analyse image quality and artefact generation due to implanted aneurysm clips using a new technology. MSCTA was performed pre- and postoperatively using a Philips Brilliance 64-detector-row CT scanner. Altogether, 32 clipping sites were analysed in 27 patients (11 female and 16 male, mean ages 52a, from 24 to 72 years). Clip number per aneurysm was 2.3 mean (from 1 to 4), 54 clips were made of titanium alloy and 5 of cobalt alloy. Altogether, image quality was rated 1.8 mean, using a scale from 1 (very good) to 5 (unserviceable) and clip artefacts were rated 2.4 mean, using a 5 point rating scale (1 no artefacts, 5 unserviceable due to artefacts). A significant loss of image quality and rise of artefacts was found when using cobalt alloy clips (1.4 versus 4.2 and 2.1 versus 4.0). In 72% of all investigations, an excellent image quality was found. Excluding the cobalt clip group, 85% of scans showed excellent image quality. Artefacts were absent or minimal (grade 1 or 2) in 69% of all investigations and in 81% in the pure titanium clip group. In 64-row MSCTA of good image quality with low artefacts, it was possible to detect small aneurysm remnants of 2mm size in individual patients. By using titanium alloy clips, in our study up to 85% of postoperative CTA images were of excellent quality with absent or minimal artefacts in 81% and seem adequate to detect small aneurysm remnants. Copyright 2010 Elsevier B.V. All rights reserved.
Annual Removal of Aboveground Plant Biomass Alters Soil Microbial Responses to Warming
Xue, Kai; Yuan, Mengting M.; Xie, Jianping; Li, Dejun; Qin, Yujia; Wu, Liyou; Deng, Ye; He, Zhili; Van Nostrand, Joy D.; Luo, Yiqi; Tiedje, James M.
2016-01-01
ABSTRACT Clipping (i.e., harvesting aboveground plant biomass) is common in agriculture and for bioenergy production. However, microbial responses to clipping in the context of climate warming are poorly understood. We investigated the interactive effects of grassland warming and clipping on soil properties and plant and microbial communities, in particular, on microbial functional genes. Clipping alone did not change the plant biomass production, but warming and clipping combined increased the C4 peak biomass by 47% and belowground net primary production by 110%. Clipping alone and in combination with warming decreased the soil carbon input from litter by 81% and 75%, respectively. With less carbon input, the abundances of genes involved in degrading relatively recalcitrant carbon increased by 38% to 137% in response to either clipping or the combined treatment, which could weaken long-term soil carbon stability and trigger positive feedback with respect to warming. Clipping alone also increased the abundance of genes for nitrogen fixation, mineralization, and denitrification by 32% to 39%. Such potentially stimulated nitrogen fixation could help compensate for the 20% decline in soil ammonium levels caused by clipping alone and could contribute to unchanged plant biomass levels. Moreover, clipping tended to interact antagonistically with warming, especially with respect to effects on nitrogen cycling genes, demonstrating that single-factor studies cannot predict multifactorial changes. These results revealed that clipping alone or in combination with warming altered soil and plant properties as well as the abundance and structure of soil microbial functional genes. Aboveground biomass removal for biofuel production needs to be reconsidered, as the long-term soil carbon stability may be weakened. PMID:27677789
DOE Office of Scientific and Technical Information (OSTI.GOV)
Penninkhof, Joan, E-mail: j.penninkhof@erasmusmc.nl; Quint, Sandra; Baaijens, Margreet
Purpose: To describe the practical use of the extended No Action Level (eNAL) setup correction protocol for breast cancer patients with surgical clips and evaluate its impact on the setup accuracy of both tumor bed and whole breast during simultaneously integrated boost treatments. Methods and Materials: For 80 patients, two orthogonal planar kilovoltage images and one megavoltage image (for the mediolateral beam) were acquired per fraction throughout the radiotherapy course. For setup correction, the eNAL protocol was applied, based on registration of surgical clips in the lumpectomy cavity. Differences with respect to application of a No Action Level (NAL) protocolmore » or no protocol were quantified for tumor bed and whole breast. The correlation between clip migration during the fractionated treatment and either the method of surgery or the time elapsed from last surgery was investigated. Results: The distance of the clips to their center of mass (COM), averaged over all clips and patients, was reduced by 0.9 {+-} 1.2 mm (mean {+-} 1 SD). Clip migration was similar between the group of patients starting treatment within 100 days after surgery (median, 53 days) and the group starting afterward (median, 163 days) (p = 0.20). Clip migration after conventional breast surgery (closing the breast superficially) or after lumpectomy with partial breast reconstructive techniques (sutured cavity). was not significantly different either (p = 0.22). Application of eNAL on clips resulted in residual systematic errors for the clips' COM of less than 1 mm in each direction, whereas the setup of the breast was within about 2 mm of accuracy. Conclusions: Surgical clips can be safely used for high-accuracy position verification and correction. Given compensation for time trends in the clips' COM throughout the treatment course, eNAL resulted in better setup accuracies for both tumor bed and whole breast than NAL.« less
Woodford, Evangeline; Brown, Julie; Bilston, Lynne E
2018-05-19
Traffic crashes have high mortality and morbidity for young children. Though many specialized child restraint systems improve injury outcomes, no large-scale studies have investigated the cross-chest clip's role during a crash, despite concerns in some jurisdictions about the potential for neck contact injuries from the clips. This study aimed to investigate the relationship between cross-chest clip use and injury outcomes in children between 0 and 4 years of age. Child passengers between 0 and 4 years of age were selected from the NASS-CDS data sets (2003-2014). Multiple regression analysis was used to model injury outcomes while controlling for age, crash severity, crash direction, and restraint type. The primary outcomes were overall Abbreviated Injury Score (AIS) 2+ injury, and the presence of any neck injury. Across all children aged 0-4 years, correct chest clip use was associated with decreased Abbreviated Injury Scale (AIS) 2+ injury (odds ratio [OR] = 0.44, 95% confidence interval [CI], 0.21-0.91) and was not associated with neck injury. However, outcomes varied by age. In children <12 months old, chest clip use was associated with decreased AIS 2+ injury (OR = 0.09, 95% CI, 0.02-0.44). Neck injury (n = 7, all AIS 1) for this age group only occurred with correct cross-chest clip use. For 1- to 4-year-old children, cross-chest clip use had no association with AIS 2+ injury, and correct use significantly decreased the odds of neck injury (OR = 0.49; 95% CI, 0.27-0.87) compared to an incorrectly used or absent cross-chest clip. No serious injuries were directly caused by the chest clips. Correct cross-chest clip use appeared to reduce injury in crashes, and there was no evidence of serious clip-induced injury in children in 5-point harness restraints.
Bahin, Farzan F; Rasouli, Khalid N; Williams, Stephen J; Lee, Eric Y T; Bourke, Michael J
2016-08-01
Clinically significant bleeding (CSPEB) is the most common adverse event following endoscopic mucosal resection (EMR) of large sessile and laterally spreading colorectal lesions (LSLs), and is associated with morbidity and resource utilization. CSPEB occurs more frequently with proximal LSLs. Prophylactic clipping of the post-EMR defect may be beneficial in CSPEB prevention. The aim of this study was to determine the cost-effectiveness of a prophylactic clipping strategy. We hypothesized that prophylactic clipping in the proximal colon was cost-effective. An economic model was applied to outcomes from the Australian Colonic Endoscopic Mucosal Resection (ACE) Study. Clip distances of 3, 5, 8, and 10 mm were analyzed. The cost of treating CSPEB was determined from an independent costing agency. The funds needed to spend (FNS) was the cost incurred in order to prevent one episode of CSPEB. A break-even analysis was performed to determine cost equivalence of the costs of clipping and CSPEB. Outcomes of 1717 LSLs (mean size 35.8 mm; 52.6 % proximal colon) that underwent EMR were analyzed. The overall rate of CSPEB was 6.4 % (proximal 8.9 %; distal 3.7 %). Endoscopic management was required in 45 % of CSPEB episodes. With a clip distance of 3 mm, the expected cost of prophylactic clipping was € 1106 per lesion compared with € 157 per lesion for the expected cost of CSPEB without clipping. At 100 % clipping efficacy, the FNS was € 14 826 (proximal and distal lesions € 9309 and € 29 540, respectively). A clip price of € 10.35 was required for the cost of clipping to offset the cost of CSPEB. A prophylactic clipping strategy is not cost-effective and at present cannot be justified for all lesions or selectively for lesions in the proximal colon. ClinicalTrials.gov (NCT01368289). © Georg Thieme Verlag KG Stuttgart · New York.
Kato, Masayuki; Jung, Yunho; Gromski, Mark A; Chuttani, Ram; Matthes, Kai
2012-01-01
Recently, endoscopic clip application devices have undergone redesign and improvements to optimize their clinical use and effectiveness. Initially designed for the treatment of bleeding nonvariceal lesions, these devices are also increasingly used for the closure of perforations, fistulas, and anastomotic leaks. Several clinical studies, both randomized and nonrandomized, have used endoscopic hemoclips for hemostasis. However, no comparative studies have yet been reported in the literature comparing the latest endoscopic clip devices for usability and effectiveness for hemostasis of acute upper GI hemorrhage. We aimed to compare the usability and efficacy of 3 different types of endoscopic clip application devices in an established experimental setting by using a porcine ex-vivo simulator of upper GI hemorrhage. Randomized, controlled, ex-vivo study. Academic medical center. Spurting vessels were created within ex-vivo porcine stomachs as published in prior studies. The vessels were attached to a pressure transducer to record the pressure of the circulating blood replacement. Before the initiation of bleeding, each vessel was randomized to 1 of 3 endoscopic clipping devices: 2 different commonly used hemoclips deployed through the working channel and 1 novel clip deployed via an over-the-scope applications device. Two investigators treated 45 bleeding sites (15 bleeding sites for each device at various randomized locations in the stomach: fundus, body, and antrum). Usability was measured via the endpoints of procedure time and quantity of clips required to achieve hemostasis. Efficacy was measured via the endpoint of pressure increase (Δp) from baseline to after treatment. All of the 45 hemostasis treatments were carried out successfully. The mean procedure times were significantly different among the hemoclips, with the clip deployed in an over-the-scope fashion requiring significantly less time to attain hemostasis compared with the other 2 clips. For number of clips needed to attain hemostasis, the clip deployed in an over-the-scope fashion was significantly superior to the others. There were also significant differences among the changes in pressure (Δp ± SD) among the different hemoclips tested. Ex-vivo study. In this prospective, randomized ex-vivo study, we observed significant differences in the usability (time to achieve hemostasis and number of clips required) and the efficacy (change in pressure achieved by the hemoclips) among the 3 clips. The clip applied in the over-the-scope fashion was superior to the other 2 tested clips with regard to time to achieve hemostasis and number of clips required. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-31
... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-663 Third Review] Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping Duty Order on Paper Clips From China... paper clips from China would be likely to lead to continuation or recurrence of material injury within a...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-26
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-826] Paper Clips From the People... the antidumping duty order on paper clips from the People's Republic of China (``PRC'') would likely... of the antidumping duty order on paper clips from the PRC pursuant to section 751(c) of the Tariff...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-26
... Seeks Comment on Application of the IP Closed Captioning Rules to Video Clips AGENCY: Federal... captioning of video clips delivered by Internet protocol (``IP''), including the extent to which industry has voluntarily captioned IP- delivered video clips. The Commission directed the Media Bureau to issue this...
Catheter Entrapment During Posterior Mitral Leaflet Pushing Maneuver for MitraClip Implantation.
Castrodeza, Javier; Amat-Santos, Ignacio J; Tobar, Javier; Varela-Falcón, Luis H
2016-06-01
MitraClip (Abbott Vascular) therapy has been reported to be an effective procedure for mitral regurgitation, especially in high-risk patients. Recently, the novel pushing maneuver technique has been described for approaching restricted and short posterior leaflets with a pigtail catheter in order to facilitate grasping of the clip. However, complications or unexpected situations may occur. We report the case of an 84-year-old patient who underwent MitraClip implantation wherein the pushing maneuver was complicated by the clip accidentally gripping the pigtail catheter along with the two leaflets.
Integrating an object system into CLIPS: Language design and implementation issues
NASA Technical Reports Server (NTRS)
Auburn, Mark
1990-01-01
This paper describes the reasons why an object system with integrated pattern-matching and object-oriented programming facilities is desirable for CLIPS and how it is possible to integrate such a system into CLIPS while maintaining the run-time performance and the low memory usage for which CLIPS is known. The requirements for an object system in CLIPS that includes object-oriented programming and integrated pattern-matching are discussed and various techniques for optimizing the object system and its integration with the pattern-matcher are presented.
CLIPS: A tool for the development and delivery of expert systems
NASA Technical Reports Server (NTRS)
Riley, Gary
1991-01-01
The C Language Integrated Production System (CLIPS) is a forward chaining rule-based language developed by the Software Technology Branch at the Johnson Space Center. CLIPS provides a complete environment for the construction of rule-based expert systems. CLIPS was designed specifically to provide high probability, low cost, and easy integration with external systems. Other key features of CLIPS include a powerful rule syntax, an interactive development environment, high performance, extensibility, a verification/validation tool, extensive documentation, and source code availability. The current release of CLIPS, version 4.3, is being used by over 2,500 users throughout the public and private community including: all NASA sites and branches of the military, numerous Federal bureaus, government contractors, 140 universities, and many companies.
Budai, Caterina; Cirillo, Luigi; Patruno, Francesco; Dall'olio, Massimo; Princiotta, Ciro; Leonardi, Marco
2014-04-01
Cerebral aneurysms must be monitored for varying periods after surgical and/or endovascular treatment and the duration of follow-up will depend on the type of therapy and the immediate post-operative outcome. Surgical clipping for intracranial aneurysms is a valid treatment but the metal clips generate artefacts so that follow-up monitoring still relies on catheter angiography. This study reports our preliminary experience with volumetric angiography using a Philips Allura Xper FD biplane system in the post-operative monitoring of aneurysm residues or major vascular changes following the surgical clipping of intracranial aneurysms. Volumetric angiography yields not only volume-rendered (VR) images, but a volume CT can also be reconstructed at high spatial and contrast resolution from a single acquisition, significantly enhancing the technique's diagnostic power. Between August 2012 and April 2013, we studied 19 patients with a total of 26 aneurysms treated by surgical clipping alone or in combination with endovascular treatment. All patients underwent standard post-operative angiographic follow-up including a rotational volumetric acquisition. Follow-up monitoring disclosed eight aneurysm residues whose assessment was optimal after surgical clipping both in patients with one metal clip and in those with two or more clips. In addition, small residues (1.3 mm) could be monitored together with any change in the calibre or course of vessels located adjacent to the clips. In conclusion, flat panel volume CT is much more reliable than the old 3D acquisitions that yielded only VR images. This is particularly true in patients with small aneurysm residues or lesions with multiple metal clips.
Virtual Cerebral Aneurysm Clipping with Real-Time Haptic Force Feedback in Neurosurgical Education.
Gmeiner, Matthias; Dirnberger, Johannes; Fenz, Wolfgang; Gollwitzer, Maria; Wurm, Gabriele; Trenkler, Johannes; Gruber, Andreas
2018-04-01
Realistic, safe, and efficient modalities for simulation-based training are highly warranted to enhance the quality of surgical education, and they should be incorporated in resident training. The aim of this study was to develop a patient-specific virtual cerebral aneurysm-clipping simulator with haptic force feedback and real-time deformation of the aneurysm and vessels. A prototype simulator was developed from 2012 to 2016. Evaluation of virtual clipping by blood flow simulation was integrated in this software, and the prototype was evaluated by 18 neurosurgeons. In 4 patients with different medial cerebral artery aneurysms, virtual clipping was performed after real-life surgery, and surgical results were compared regarding clip application, surgical trajectory, and blood flow. After head positioning and craniotomy, bimanual virtual aneurysm clipping with an original forceps was performed. Blood flow simulation demonstrated residual aneurysm filling or branch stenosis. The simulator improved anatomic understanding for 89% of neurosurgeons. Simulation of head positioning and craniotomy was considered realistic by 89% and 94% of users, respectively. Most participants agreed that this simulator should be integrated into neurosurgical education (94%). Our illustrative cases demonstrated that virtual aneurysm surgery was possible using the same trajectory as in real-life cases. Both virtual clipping and blood flow simulation were realistic in broad-based but not calcified aneurysms. Virtual clipping of a calcified aneurysm could be performed using the same surgical trajectory, but not the same clip type. We have successfully developed a virtual aneurysm-clipping simulator. Next, we will prospectively evaluate this device for surgical procedure planning and education. Copyright © 2018 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Olsen, Walter R.; Sommers, William A.
2005-01-01
Video and DVD clips give participants an opportunity to explore values and ideas, learn about one another, and, in the process, build a stronger learning community. "Energizing Staff Development Using Film Clips" is a collection of film and television clips that staff developers can use to encourage discussion and reflection on pertinent, common…
Müller, J; Schön, F; Helms, J
1998-04-01
There is a reported 1% incidence of delayed migration of extrusions of the electrode arrays out of the cochlea. A titanium clip to fix the electrode array of the MED EL Combi 40 Cochlear Implant System is described. The clip is designed and shaped in a double U configuration. The clip material allows easy adaption to the individual anatomical situation. The clip is fixed to a bony bridge at the incus bar and fixes the electrode in a plane parallel to the chorda facial angle. It is closed around the electrode similarly to a stapes piston around the incus. Additional tests which examined the possible risk of damaging the electrode carrier and clinical findings are described. The clip was used in 23 cases with a follow-up period up to 1 year. No signs for dislocation of the electrode were found. In one revision case the clip was covered with a thin mucosal layer. The electrode array showed no signs of damage. Intraoperative findings confirmed the experimental tests on the electrode fixation. The titanium clip facilitates safe and quick fixation of the electrode array and prevents dislocation. its flexibility and shape minimizes the risk of damage.
Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips
Schulz-Wendtland, R.; Dankerl, P.; Dilbat, G.; Bani, M.; Fasching, P. A.; Heusinger, K.; Lux, M. P.; Loehberg, C. R.; Jud, S. M.; Rauh, C.; Bayer, C. M.; Beckmann, M. W.; Wachter, D. L.; Uder, M.; Meier-Meitinger, M.; Brehm, B.
2015-01-01
Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p < 0.05). Conclusion: The use of digital breast tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography. PMID:25684789
A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability.
Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Ropers, H Hilger; Galjart, Niels; Najmabadi, Hossein
2015-03-01
In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score = 3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which specifically associates with the ends of growing MTs. These proteins regulate MT dynamic behavior and are important for MT-mediated transport over the length of axons and dendrites. As such, CLIP1 may have a role in neuronal development. We studied lymphoblastoid and skin fibroblast cell lines established from healthy and affected patients. RT-PCR and western blot analyses showed the absence of CLIP1 transcript and protein in lymphoblastoid cells derived from affected patients. Furthermore, immunofluorescence analyses showed MT plus-end staining only in fibroblasts containing the wild-type (and not the mutant) CLIP1 protein. Collectively, our data suggest that defects in CLIP1 may lead to ARID.
A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability
Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Ropers, H Hilger; Galjart, Niels; Najmabadi, Hossein
2015-01-01
In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score=3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which specifically associates with the ends of growing MTs. These proteins regulate MT dynamic behavior and are important for MT-mediated transport over the length of axons and dendrites. As such, CLIP1 may have a role in neuronal development. We studied lymphoblastoid and skin fibroblast cell lines established from healthy and affected patients. RT-PCR and western blot analyses showed the absence of CLIP1 transcript and protein in lymphoblastoid cells derived from affected patients. Furthermore, immunofluorescence analyses showed MT plus-end staining only in fibroblasts containing the wild-type (and not the mutant) CLIP1 protein. Collectively, our data suggest that defects in CLIP1 may lead to ARID. PMID:24569606
Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K
2007-06-01
Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.
The Emotional Movie Database (EMDB): a self-report and psychophysiological study.
Carvalho, Sandra; Leite, Jorge; Galdo-Álvarez, Santiago; Gonçalves, Oscar F
2012-12-01
Film clips are an important tool for evoking emotional responses in the laboratory. When compared with other emotionally potent visual stimuli (e.g., pictures), film clips seem to be more effective in eliciting emotions for longer periods of time at both the subjective and physiological levels. The main objective of the present study was to develop a new database of affective film clips without auditory content, based on a dimensional approach to emotional stimuli (valence, arousal and dominance). The study had three different phases: (1) the pre-selection and editing of 52 film clips (2) the self-report rating of these film clips by a sample of 113 participants and (3) psychophysiological assessment [skin conductance level (SCL) and the heart rate (HR)] on 32 volunteers. Film clips from different categories were selected to elicit emotional states from different quadrants of affective space. The results also showed that sustained exposure to the affective film clips resulted in a pattern of a SCL increase and HR deceleration in high arousal conditions (i.e., horror and erotic conditions). The resulting emotional movie database can reliably be used in research requiring the presentation of non-auditory film clips with different ratings of valence, arousal and dominance.
Koordeman, Renske; Anschutz, Doeschka J; Engels, Rutger C M E
2014-07-01
This study examined the effects of alcohol portrayals on transportation and attitude toward a movie. In addition, we examined whether positive and negative movie alcohol portrayals affect transportation into and attitude toward the movie. A within-subject design was used in which participants were exposed to 8 different movie clips containing alcohol (positive or negative context) or no alcohol portrayals in a controlled laboratory setting. A total of 159 college students (84 males and 75 females) ages 18 to 30 participated in the experiment. Transportation and attitude toward the movie were measured after each movie clip. Participants were more transported into and had a more positive attitude toward movie clips with alcohol portrayals compared to the same movie clips with no alcohol portrayal. In addition, participants were more transported into movie clips with negative alcohol (NA) portrayals compared to clips with positive alcohol (PA) portrayals. For attitude toward the movie, opposite results were found. Participants had a more positive attitudes toward clips with PA portrayals compared to clips with NA portrayals. The way alcohol is portrayed in movies may contribute to how people evaluate and get transported in movies. Copyright © 2014 by the Research Society on Alcoholism.
NASA Technical Reports Server (NTRS)
Hall, Lawrence O.; Bennett, Bonnie H.; Tello, Ivan
1994-01-01
A parallel version of CLIPS 5.1 has been developed to run on Intel Hypercubes. The user interface is the same as that for CLIPS with some added commands to allow for parallel calls. A complete version of CLIPS runs on each node of the hypercube. The system has been instrumented to display the time spent in the match, recognize, and act cycles on each node. Only rule-level parallelism is supported. Parallel commands enable the assertion and retraction of facts to/from remote nodes working memory. Parallel CLIPS was used to implement a knowledge-based command, control, communications, and intelligence (C(sup 3)I) system to demonstrate the fusion of high-level, disparate sources. We discuss the nature of the information fusion problem, our approach, and implementation. Parallel CLIPS has also be used to run several benchmark parallel knowledge bases such as one to set up a cafeteria. Results show from running Parallel CLIPS with parallel knowledge base partitions indicate that significant speed increases, including superlinear in some cases, are possible.
Mulgrew, K E; Volcevski-Kostas, D
2012-09-01
Viewing idealized images has been shown to reduce men's body satisfaction; however no research has examined the impact of music video clips. This was the first study to examine the effects of exposure to muscular images in music clips on men's body image, mood and cognitions. Ninety men viewed 5 min of clips containing scenery, muscular or average-looking singers, and completed pre- and posttest measures of mood and body image. Appearance schema activation was also measured. Men exposed to the muscular clips showed poorer posttest levels of anger, body and muscle tone satisfaction compared to men exposed to the scenery or average clips. No evidence of schema activation was found, although potential problems with the measure are noted. These preliminary findings suggest that even short term exposure to music clips can produce negative effects on men's body image and mood. Copyright © 2012 Elsevier Ltd. All rights reserved.
Ho, Daniel W H; Sze, Karen M F; Ng, Irene O L
2015-08-28
Viral integration into the human genome upon infection is an important risk factor for various human malignancies. We developed viral integration site detection tool called Virus-Clip, which makes use of information extracted from soft-clipped sequencing reads to identify exact positions of human and virus breakpoints of integration events. With initial read alignment to virus reference genome and streamlined procedures, Virus-Clip delivers a simple, fast and memory-efficient solution to viral integration site detection. Moreover, it can also automatically annotate the integration events with the corresponding affected human genes. Virus-Clip has been verified using whole-transcriptome sequencing data and its detection was validated to have satisfactory sensitivity and specificity. Marked advancement in performance was detected, compared to existing tools. It is applicable to versatile types of data including whole-genome sequencing, whole-transcriptome sequencing, and targeted sequencing. Virus-Clip is available at http://web.hku.hk/~dwhho/Virus-Clip.zip.
CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION)
NASA Technical Reports Server (NTRS)
Riley, G.
1994-01-01
The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh version each contain a windowing variant of CLIPS as well as the standard line oriented version. The mouse/window interface version for the PC works with a Microsoft compatible mouse or without a mouse. This window version uses the proprietary CURSES library for the PC, but a working executable of the window version is provided. The window oriented version for the Macintosh includes a version which uses a full Macintosh-style interface, including an integrated editor. This version allows the user to observe the changing fact base and rule activations in separate windows while a CLIPS program is executing. The IBM PC version is available bundled with CLIPSITS, The CLIPS Intelligent Tutoring System for a special combined price (COS-10025). The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. The program was developed for the IBM PC series with a hard disk. CLIPSITS is also available separately as MSC-21679. The CLIPS program is written in C for interactive execution and has been implemented on an IBM PC computer operating under DOS, a Macintosh and DEC VAX series computers operating under VMS or ULTRIX. The line oriented version should run on any computer system which supports a full (Kernighan and Ritchie) C compiler or the ANSI standard C language. CLIPS was developed in 1986 and Version 4.2 was released in July of 1988. Version 4.3 was released in June of 1989.
CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (MACINTOSH VERSION)
NASA Technical Reports Server (NTRS)
Culbert, C.
1994-01-01
The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh version each contain a windowing variant of CLIPS as well as the standard line oriented version. The mouse/window interface version for the PC works with a Microsoft compatible mouse or without a mouse. This window version uses the proprietary CURSES library for the PC, but a working executable of the window version is provided. The window oriented version for the Macintosh includes a version which uses a full Macintosh-style interface, including an integrated editor. This version allows the user to observe the changing fact base and rule activations in separate windows while a CLIPS program is executing. The IBM PC version is available bundled with CLIPSITS, The CLIPS Intelligent Tutoring System for a special combined price (COS-10025). The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. The program was developed for the IBM PC series with a hard disk. CLIPSITS is also available separately as MSC-21679. The CLIPS program is written in C for interactive execution and has been implemented on an IBM PC computer operating under DOS, a Macintosh and DEC VAX series computers operating under VMS or ULTRIX. The line oriented version should run on any computer system which supports a full (Kernighan and Ritchie) C compiler or the ANSI standard C language. CLIPS was developed in 1986 and Version 4.2 was released in July of 1988. Version 4.3 was released in June of 1989.
CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION WITH CLIPSITS)
NASA Technical Reports Server (NTRS)
Riley, , .
1994-01-01
The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh version each contain a windowing variant of CLIPS as well as the standard line oriented version. The mouse/window interface version for the PC works with a Microsoft compatible mouse or without a mouse. This window version uses the proprietary CURSES library for the PC, but a working executable of the window version is provided. The window oriented version for the Macintosh includes a version which uses a full Macintosh-style interface, including an integrated editor. This version allows the user to observe the changing fact base and rule activations in separate windows while a CLIPS program is executing. The IBM PC version is available bundled with CLIPSITS, The CLIPS Intelligent Tutoring System for a special combined price (COS-10025). The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. The program was developed for the IBM PC series with a hard disk. CLIPSITS is also available separately as MSC-21679. The CLIPS program is written in C for interactive execution and has been implemented on an IBM PC computer operating under DOS, a Macintosh and DEC VAX series computers operating under VMS or ULTRIX. The line oriented version should run on any computer system which supports a full (Kernighan and Ritchie) C compiler or the ANSI standard C language. CLIPS was developed in 1986 and Version 4.2 was released in July of 1988. Version 4.3 was released in June of 1989.
Apparatus for the compact cooling of modules
Iyengar, Madhusudan K.; Parida, Pritish R.
2015-07-07
An apparatus for the compact cooling of modules. The apparatus includes a clip, a first cover plate coupled to a first side of the clip, a second cover plate coupled to a second side of the clip opposite to the first side of the clip, a first frame thermally coupled to the first cover plate, and a second frame thermally coupled to the second cover plate. Each of the first frame and the second frame may include a plurality of channels for passing coolant through the first frame and the second frame, respectively. Additionally, the apparatus may further include a filler for directing coolant through the plurality of channels, and for blocking coolant from flowing along the first side of the clip and the second side of the clip.
Importance of nasal clipping in screening investigations of flow volume curve.
Yanev, I
1992-01-01
Comparative analysis of some basic lung indices obtained from a screening investigation of the flow volume curve by using two techniques, with a nose clip and without a nose clip, was made on a cohort of 86 workers in a factory shop for the production of bearings. We found no statistically significant differences between the indices obtained by the two techniques. Our study showed that the FVC and FEV1 obtained in workers without using nose clips were equal to or better than those obtained using nose clips in 60% of the workers. The reproducibility of the two methods was similar. The analysis of the data has shown that the flow volume curve investigation gives better results when performed without a nose clip, especially in industrial conditions.
CLIPS/Ada: An Ada-based tool for building expert systems
NASA Technical Reports Server (NTRS)
White, W. A.
1990-01-01
Clips/Ada is a production system language and a development environment. It is functionally equivalent to the CLIPS tool. CLIPS/Ada was developed in order to provide a means of incorporating expert system technology into projects where the use of the Ada language had been mandated. A secondary purpose was to glean information about the Ada language and its compilers. Specifically, whether or not the language and compilers were mature enough to support AI applications. The CLIPS/Ada tool is coded entirely in Ada and is designed to be used by Ada systems that require expert reasoning.
A distributed Clips implementation: dClips
NASA Technical Reports Server (NTRS)
Li, Y. Philip
1993-01-01
A distributed version of the Clips language, dClips, was implemented on top of two existing generic distributed messaging systems to show that: (1) it is easy to create a coarse-grained parallel programming environment out of an existing language if a high level messaging system is used; and (2) the computing model of a parallel programming environment can be changed easily if we change the underlying messaging system. dClips processes were first connected with a simple master-slave model. A client-server model with intercommunicating agents was later implemented. The concept of service broker is being investigated.
Successful removal of football helmet face-mask clips after 1 season of use.
Scibek, Jason S; Gatti, Joseph M; McKenzie, Jennifer I
2012-01-01
Whereas many researchers have assessed the ability to remove loop straps in traditional face-mask attachment systems after at least 1 season of use, research in which the effectiveness of the Riddell Quick Release (QR) Face Guard Attachment System clip after 1 season has been assessed is limited. To examine the success rate of removing the QR clips after 1 season of use at the Football Championship Subdivision level. We hypothesized that 1 season of use would negatively affect the removal rate of the QR clip but repeated clip-removal trials would improve the removal rate. Retrospective, quasi-experimental design. Controlled laboratory study. Sixty-three football helmets from a National Collegiate Athletic Association Division I university located in western Pennsylvania used during the 2008 season were tested. Three certified athletic trainers (2 men, 1 woman; age = 31.3 ± 3.06 years, time certified = 9.42 ± 2.65 years) attempted to remove the QR clips from each helmet with the tool provided by the manufacturer. Helmets then were reassembled to allow each athletic trainer to attempt clip removal. The dependent variables were total left clips removed (TCR-L), total right clips removed (TCR-R), and total clips removed (TCR). Success rate of clip removal (SRCR) also was assessed. Percentages for TCR-L, TCR-R, and TCR were 100% (189 of 189), 96.30% (182 of 189), and 98.15% (371 of 378), respectively. A paired-samples t test revealed a difference between TCR-R and TCR-L (t(188) = 2.689, P = .008, μ(d) = 0.037, 95% confidence interval [CI] = 0.064, 0.010). The percentage for SRCR was 96.30% (n = 182), whereas SRCR percentages for trials 1, 2, and 3 were 95.24% (n = 60), 98.41% (n = 62), and 95.24% (n = 60), respectively, and did not represent a difference (F(2,186) = 0.588, P = .56, 95% (CI) = 0.94, 0.99). Our results indicated favorable and consistent success rates for QR clip removal after 1 season of use. Whereas the QR clip is an advancement in face-mask technology, continued examination of this system is required to ensure the highest level of function, allowing for effective management of the helmeted athlete.
Successful Removal of Football Helmet Face-Mask Clips After 1 Season of Use
Scibek, Jason S.; Gatti, Joseph M.; McKenzie, Jennifer I.
2012-01-01
Context Whereas many researchers have assessed the ability to remove loop straps in traditional face-mask attachment systems after at least 1 season of use, research in which the effectiveness of the Riddell Quick Release (QR) Face Guard Attachment System clip after 1 season has been assessed is limited. Objective To examine the success rate of removing the QR clips after 1 season of use at the Football Championship Subdivision level. We hypothesized that 1 season of use would negatively affect the removal rate of the QR clip but repeated clip-removal trials would improve the removal rate. Design Retrospective, quasi-experimental design. Setting Controlled laboratory study. Patients or Other Participants Sixty-three football helmets from a National Collegiate Athletic Association Division I university located in western Pennsylvania used during the 2008 season were tested. Intervention(s) Three certified athletic trainers (2 men, 1 woman; age = 31.3 ± 3.06 years, time certified = 9.42 ± 2.65 years) attempted to remove the QR clips from each helmet with the tool provided by the manufacturer. Helmets then were reassembled to allow each athletic trainer to attempt clip removal. Main Outcome Measure(s) The dependent variables were total left clips removed (TCR-L), total right clips removed (TCR-R), and total clips removed (TCR). Success rate of clip removal (SRCR) also was assessed. Results Percentages for TCR-L, TCR-R, and TCR were 100% (189 of 189), 96.30% (182 of 189), and 98.15% (371 of 378), respectively. A paired-samples t test revealed a difference between TCR-R and TCR-L (t188 = −2.689, P = .008, μd = 0.037, 95% confidence interval [CI] = −0.064, −0.010). The percentage for SRCR was 96.30% (n = 182), whereas SRCR percentages for trials 1, 2, and 3 were 95.24% (n = 60), 98.41% (n = 62), and 95.24% (n = 60), respectively, and did not represent a difference (F2,186 = 0.588, P = .56, 95% CI = 0.94, 0.99). Conclusions Our results indicated favorable and consistent success rates for QR clip removal after 1 season of use. Whereas the QR clip is an advancement in face-mask technology, continued examination of this system is required to ensure the highest level of function, allowing for effective management of the helmeted athlete. PMID:22889659
Paul P. Kormanik; Shi-Jean S. Sung; T.L. Kormanik; Stanley J. Zarnoch
1994-01-01
Seedlings from three open-pollinated half-sib white oak seedlots were clipped in mid-July and their development was compared to nonclipped controls after one growing season.In general when data were analyzed by family, clipped seedlings were significantly less desirable in three to six of the eight variables tested.Numerically, in all families seedlots, the clipped...
Clips as a knowledge based language
NASA Technical Reports Server (NTRS)
Harrington, James B.
1987-01-01
CLIPS is a language for writing expert systems applications on a personal or small computer. Here, the CLIPS programming language is described and compared to three other artificial intelligence (AI) languages (LISP, Prolog, and OPS5) with regard to the processing they provide for the implementation of a knowledge based system (KBS). A discussion is given on how CLIPS would be used in a control system.
Paluch, Lee-Ronn; Lieggi, Christine C; Dumont, Magali; Monette, Sebastien; Riedel, Elyn R; Lipman, Neil S
2014-01-01
Toe clipping is used to identify and genotype preweanling mice, but the procedure generates concerns relevant to pain and distress. The few pertinent studies available evaluated mice between postnatal days (PND) 3 and 7, advocate the use of toe clipping in mice PND 7 or younger, and identify handling as the most distressing aspect of the procedure. Because both toe and tail clipping may be necessary in older mice to obtain sufficient DNA for genotyping, we surmised that performing these procedures concurrently to minimize handling would be beneficial. We also examined reflex development until PND 21 and adult behavior at 8 to 10 wk of age in mice toe clipped at PND 7 or 17 and the benefits of using topical vapocoolant anesthesia. C57BL/6J pups at PND 7 and 17 were assigned to 1 of 4 groups: 1) clipping of digit 3 of contralateral fore- and hindpaws; 2) toe clipping after topical vapocoolant anesthesia; 3) unclipped, unsprayed controls; and, 4) unclipped and vapocoolant-sprayed. Compared with unanesthetized pups, those sprayed with vapocoolant vocalized and struggled more when handled and had more bleeding, erythema, and swelling, which persisted for as long as 12 h after toe clipping. Reflex development, anxiety, locomotion, and motor coordination were not different among groups or with regard to the age of toe clipping. No tissue reaction was noted microscopically in paws collected at 10 wk of age. We conclude that the use of vapocoolant cannot be recommended due to its harmful effects and that toe clipping at PND 7 or 17 does not significantly affect the long-term welfare of mice. PMID:24602538
Qiu, Guoqin; Wen, Dengshun; DU, Xianghui; Sheng, Liming; Zhou, Xia; Ji, Yongling; Bao, Wuan; Zhang, Danhong; Cheng, Lei
2016-07-01
In the present study, clips were used as markers to evaluate displacement differences between proximal and distal ends of esophageal tumors and to test whether their internal target volume (ITV) margins should be determined separately. A total of 23 patients with mid-upper thoracic esophageal squamous-cell carcinoma, a tumor length of ≤8 cm and an esophageal lumen suitable for endoscopic ultrasonography were recruited for the present study. Clips were implanted endoscopically at the proximal and distal ends of the esophageal tumor (upper and lower clips). In a further exploratory study on 16 of the patients, a third clip was placed at the distal esophagus 2 cm above the gastro-esophageal junction (GEJ) (cardiac clip). The clips were contoured for all 10 phases of the four-dimensional computed tomography and the maximum displacements of the clip centroids among different breathing phases in left-right (LR), superior-inferior (SI) and anterior-posterior (AP) directions were marked as x, y and z, respectively. The ITV margins that covered 95% of the LR, SI and AP motion were 2.89, 5.00 and 2.36 mm, respectively. Axial displacement (y) was greater than radial displacement (x, z; P<0.05). It was also revealed that LR(x), SI(y) and AP(z) displacement of cardiac clips was greater than that of upper or lower clips (P<0.05). Differences in the axial and radial displacement of the upper and lower clips indicated that axial and radial ITV margins should be determined separately. However, further study is required on patients in whom the distal tumor end is located in proximity to the GEJ.
A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat
Chelko, Stephen P.; Schmiedt, Chad W.; Lewis, Tristan H.; Lewis, Stephen J.
2012-01-01
The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40–60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips may also be easily dislodged from the renal artery following placement. Therefore, we designed and tested a novel vascular clip possessing design features to maintain both gap width and position around the renal artery. In this initial study, application of these new clips to the left renal artery produced reliable and consistent levels of hypertension in rats. Nine-day application of clips with gap widths of 0.27, 0.25, and 0.23 mm elicited higher mean arterial blood pressures of 112 ± 4, 121 ± 6, and 135 ± 7 mmHg, respectively (n = 8 for each group), than those of sham-operated controls (95 ± 2 mmHg, n = 8). Moreover, 8 out of 8 rats in each of the 0.23 and 0.25 mm 2K1C groups were hypertensive, whereas 7 out of 8 rats in the 0.27 mm 2K1C group were hypertensive. Plasma renin concentrations were also increased in all 2K1C groups compared with sham-operated controls. In summary, this novel clip design may help eliminate the large degree of unreliability commonly encountered with the 2K1C model. PMID:22074718
A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat.
Chelko, Stephen P; Schmiedt, Chad W; Lewis, Tristan H; Lewis, Stephen J; Robertson, Tom P
2012-02-01
The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40-60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips may also be easily dislodged from the renal artery following placement. Therefore, we designed and tested a novel vascular clip possessing design features to maintain both gap width and position around the renal artery. In this initial study, application of these new clips to the left renal artery produced reliable and consistent levels of hypertension in rats. Nine-day application of clips with gap widths of 0.27, 0.25, and 0.23 mm elicited higher mean arterial blood pressures of 112 ± 4, 121 ± 6, and 135 ± 7 mmHg, respectively (n = 8 for each group), than those of sham-operated controls (95 ± 2 mmHg, n = 8). Moreover, 8 out of 8 rats in each of the 0.23 and 0.25 mm 2K1C groups were hypertensive, whereas 7 out of 8 rats in the 0.27 mm 2K1C group were hypertensive. Plasma renin concentrations were also increased in all 2K1C groups compared with sham-operated controls. In summary, this novel clip design may help eliminate the large degree of unreliability commonly encountered with the 2K1C model.
CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (UNIX VERSION)
NASA Technical Reports Server (NTRS)
Donnell, B.
1994-01-01
CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.
CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (IBM PC VERSION)
NASA Technical Reports Server (NTRS)
Donnell, B.
1994-01-01
CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.
CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (MACINTOSH VERSION)
NASA Technical Reports Server (NTRS)
Riley, G.
1994-01-01
CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.
CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (DEC VAX VMS VERSION)
NASA Technical Reports Server (NTRS)
Donnell, B.
1994-01-01
CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.
Lehmer, Larisa M; Ragsdale, Bruce D; Daniel, John; Hayashi, Edwin; Kvalstad, Robert
2011-01-01
A plastic bag clip was incidentally found anchored in the mucosa of a partial colectomy specimen 2.6 cm proximal to a ruptured diverticulum for which the patient, a mentally retarded, diabetic, 58-year-old man, underwent surgery. Over 20 cases of accidental ingestion of plastic bag clips have been published. Known complications include small bowel perforation, obstruction, dysphagia, gastrointestinal bleeding and colonic impaction. Preoperative diagnosis of plastic clips lodged in the gastrointestinal tract is frustrated due to radiographic translucency. This occult threat could likely be prevented by the design of gastrointestinally safe, plastic-bag-sealing devices. Presented here is a morphologically based classification of bag clips as a possible guide for determining the most hazardous varieties and to aid further discussions of their impact on health. PMID:22679182
CLIPS interface development tools and their application
NASA Technical Reports Server (NTRS)
Engel, Bernard A.; Rewerts, Chris C.; Srinivasan, Raghavan; Rogers, Joseph B.; Jones, Don D.
1990-01-01
A package of C-based PC user interface development functions has been developed and integrated into CLIPS. The primary function is ASK which provides a means to ask the user questions via multiple choice menus or the keyboard and then returns the user response to CLIPS. A parameter-like structure supplies information for the interface. Another function, SHOW, provides a means to paginate and display text. A third function, TITLE, formats and displays title screens. A similar set of C-based functions that are more general and thus will run on UNIX and machines have also been developed. Seven expert system applications were transformed from commercial development environments into CLIPS and utilize ASK, SHOW, and TITLE. Development of numerous new expert system applications using CLIPS and these interface functions has started. These functions greatly reduce the time required to build interfaces for CLIPS applications.
Effects of Japanese beetle (Coleoptera: Scarabaeidae) and silk clipping in field corn.
Steckel, Sandy; Stewart, S D; Tindall, K V
2013-10-01
Japanese beetle (Popillia japonica Newman) is an emerging silk-feeding insect found in fields in the lower Corn Belt and Midsouthern United States. Studies were conducted in 2010 and 2011 to evaluate how silk clipping in corn affects pollination and yield parameters. Manually clipping silks once daily had modest effects on yield parameters. Sustained clipping by either manually clipping silks three times per day or by caging Japanese beetles onto ears affected total kernel weight if it occurred during early silking (R1 growth stage). Manually clipping silks three times per day for the first 5 d of silking affected the number of kernels per ear, total kernel weight, and the weight of individual kernels. Caged beetles fed on silks and, depending on the number of beetles caged per ear, reduced the number of kernels per ear. Caging eight beetles per ear significantly reduced total kernel weight compared with noninfested ears. Drought stress before anthesis appeared to magnify the impact of silk clipping by Japanese beetles. There was evidence of some compensation for reduced pollination by increasing the size of pollinated kernels within the ear. Our results showed that it requires sustained silk clipping during the first week of silking to have substantial impacts on pollination and yield parameters, at least under good growing conditions. Some states recommend treating for Japanese beetle when three Japanese beetles per ear are found, silks are clipped to < 13 mm, and pollination is < 50% complete, and that recommendation appears to be adequate.
Suture retraction technique to prevent parent vessel obstruction following aneurysm tandem clipping.
Rayan, Tarek; Amin-Hanjani, Sepideh
2015-08-01
With large or giant aneurysms, the use of multiple tandem clips can be essential for complete obliteration of the aneurysm. One potential disadvantage, however, is the considerable cumulative weight of these clips, which may lead to kinking of the underlying parent vessels and obstruction of flow. The authors describe a simple technique to address this problem, guided by intraoperative blood flow measurements, in a patient with a ruptured near-giant 2.2 × 1.7-cm middle cerebral artery bifurcation aneurysm that was treated with the tandem clipping technique. A total of 11 clips were applied in a vertical stacked fashion. The cumulative weight of the clips caused kinking of the temporal M2 branch of the bifurcation with reduction of flow. A 4-0 Nurolon suture tie was applied to the hub of one of the clips and was tethered to the dura of the sphenoid ridge by a small mini-clip and reinforced by application of tissue sealant. The patient underwent intraoperative indocyanine green videoangiography as well as catheter angiography, which demonstrated complete aneurysmal obliteration and preservation of vessel branches. Postoperative angiography confirmed patency of the bifurcation vessels with mild vasospasm. The patient had a full recovery with no postoperative complications and was neurologically intact at her 6-month follow-up. The suture retraction technique allows a simple solution to parent vessel obstruction following aneurysm tandem clipping, in conjunction with the essential guidance provided by intraoperative flow measurements.
Expert system technologies for Space Shuttle decision support: Two case studies
NASA Technical Reports Server (NTRS)
Ortiz, Christopher J.; Hasan, David A.
1994-01-01
This paper addresses the issue of integrating the C Language Integrated Production System (CLIPS) into distributed data acquisition environments. In particular, it presents preliminary results of some ongoing software development projects aimed at exploiting CLIPS technology in the new mission control center (MCC) being built at NASA Johnson Space Center. One interesting aspect of the control center is its distributed architecture; it consists of networked workstations which acquire and share data through the NASA/JSC-developed information sharing protocol (ISP). This paper outlines some approaches taken to integrate CLIPS and ISP in order to permit the development of intelligent data analysis applications which can be used in the MCC. Three approaches to CLIPS/IPS integration are discussed. The initial approach involves clearly separating CLIPS from ISP using user-defined functions for gathering and sending data to and from a local storage buffer. Memory and performance drawbacks of this design are summarized. The second approach involves taking full advantage of CLIPS and the CLIPS Object-Oriented Language (COOL) by using objects to directly transmit data and state changes from ISP to COOL. Any changes within the object slots eliminate the need for both a data structure and external function call thus taking advantage of the object matching capabilities within CLIPS 6.0. The final approach is to treat CLIPS and ISP as peer toolkits. Neither is embedded in the other; rather the application interweaves calls to each directly in the application source code.
NASA Technical Reports Server (NTRS)
Riley, Gary
1991-01-01
The C Language Integrated Production System (CLIPS) is a forward chaining rule based language developed by NASA. CLIPS was designed specifically to provide high portability, low cost, and easy integration with external systems. The current release of CLIPS, version 4.3, is being used by over 2500 users throughout the public and private community. The primary addition to the next release of CLIPS, version 5.0, will be the CLIPS Object Oriented Language (COOL). The major capabilities of COOL are: class definition with multiple inheritance and no restrictions on the number, types, or cardinality of slots; message passing which allows procedural code bundled with an object to be executed; and query functions which allow groups of instances to be examined and manipulated. In addition to COOL, numerous other enhancements were added to CLIPS including: generic functions (which allow different pieces of procedural code to be executed depending upon the types or classes of the arguments); integer and double precision data type support; multiple conflict resolution strategies; global variables; logical dependencies; type checking on facts; full ANSI compiler support; and incremental reset for rules.
Clipping in neurocontrol by adaptive dynamic programming.
Fairbank, Michael; Prokhorov, Danil; Alonso, Eduardo
2014-10-01
In adaptive dynamic programming, neurocontrol, and reinforcement learning, the objective is for an agent to learn to choose actions so as to minimize a total cost function. In this paper, we show that when discretized time is used to model the motion of the agent, it can be very important to do clipping on the motion of the agent in the final time step of the trajectory. By clipping, we mean that the final time step of the trajectory is to be truncated such that the agent stops exactly at the first terminal state reached, and no distance further. We demonstrate that when clipping is omitted, learning performance can fail to reach the optimum, and when clipping is done properly, learning performance can improve significantly. The clipping problem we describe affects algorithms that use explicit derivatives of the model functions of the environment to calculate a learning gradient. These include backpropagation through time for control and methods based on dual heuristic programming. However, the clipping problem does not significantly affect methods based on heuristic dynamic programming, temporal differences learning, or policy-gradient learning algorithms.
Film clips and narrative text as subjective emotion elicitation techniques.
Zupan, Barbra; Babbage, Duncan R
2017-01-01
Film clips and narrative text are useful techniques in eliciting emotion in a laboratory setting but have not been examined side-by-side using the same methodology. This study examined the self-identification of emotions elicited by film clip and narrative text stimuli to confirm that selected stimuli appropriately target the intended emotions. Seventy participants viewed 30 film clips, and 40 additional participants read 30 narrative texts. Participants identified the emotion experienced (happy, sad, angry, fearful, neutral-six stimuli each). Eighty-five percent of participants self-identified the target emotion for at least two stimuli for all emotion categories of film clips, except angry (only one) and for all categories of narrative text, except fearful (only one). The most effective angry text was correctly identified 74% of the time. Film clips were more effective in eliciting all target emotions in participants for eliciting the correct emotion (angry), intensity rating (happy, sad), or both (fearful).
Mounting clips for panel installation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph
2017-02-14
An exemplary mounting clip for removably attaching panels to a supporting structure comprises a base, spring locking clips, a lateral flange, a lever flange, and a spring bonding pad. The spring locking clips extend upwardly from the base. The lateral flange extends upwardly from a first side of the base. The lateral flange comprises a slot having an opening configured to receive at least a portion of one of the one or more panels. The lever flange extends outwardly from the lateral flange. The spring bonding flange extends downwardly from the lever flange. At least a portion of the firstmore » spring bonding flange comprises a serrated edge for gouging at least a portion of the one or more panels when the one or more panels are attached to the mounting clip to electrically and mechanically couple the one or more panels to the mounting clip.« less
The use of video clips in teleconsultation for preschool children with movement disorders.
Gorter, Hetty; Lucas, Cees; Groothuis-Oudshoorn, Karin; Maathuis, Carel; van Wijlen-Hempel, Rietje; Elvers, Hans
2013-01-01
To investigate the reliability and validity of video clips in assessing movement disorders in preschool children. The study group included 27 children with neuromotor concerns. The explorative validity group included children with motor problems (n = 21) or with typical development (n = 9). Hempel screening was used for live observation of the child, full recording, and short video clips. The explorative study tested the validity of the clinical classifications "typical" or "suspect." Agreement between live observation and the full recording was almost perfect; Agreement for the clinical classification "typical" or "suspect" was substantial. Agreement between the full recording and short video clips was substantial to moderate. The explorative validity study, based on short video clips and the presence of a neuromotor developmental disorder, showed substantial agreement. Hempel screening enables reliable and valid observation of video clips, but further research is necessary to demonstrate the predictive value.
Embedding CLIPS in a database-oriented diagnostic system
NASA Technical Reports Server (NTRS)
Conway, Tim
1990-01-01
This paper describes the integration of C Language Production Systems (CLIPS) into a powerful portable maintenance aid (PMA) system used for flightline diagnostics. The current diagnostic target of the system is the Garrett GTCP85-180L, a gas turbine engine used as an Auxiliary Power Unit (APU) on some C-130 military transport aircraft. This project is a database oriented approach to a generic diagnostic system. CLIPS is used for 'many-to-many' pattern matching within the diagnostics process. Patterns are stored in database format, and CLIPS code is generated by a 'compilation' process on the database. Multiple CLIPS rule sets and working memories (in sequence) are supported and communication between the rule sets is achieved via the export and import commands. Work is continuing on using CLIPS in other portions of the diagnostic system and in re-implementing the diagnostic system in the Ada language.
Chugh, A Jessey; Pace, Jonathan R; Singer, Justin; Tatsuoka, Curtis; Hoffer, Alan; Selman, Warren R; Bambakidis, Nicholas C
2017-03-01
OBJECTIVE The field of neurosurgery is constantly undergoing improvements and advances, both in technique and technology. Cerebrovascular neurosurgery is no exception, with endovascular treatments changing the treatment paradigm. Clipping of aneurysms is still necessary, however, and advances are still being made to improve patient outcomes within the microsurgical treatment of aneurysms. Surgical rehearsal platforms are surgical simulators that offer the opportunity to rehearse a procedure prior to entering the operative suite. This study is designed to determine whether use of a surgical rehearsal platform in aneurysm surgery is helpful in decreasing aneurysm dissection time and clip manipulation of the aneurysm. METHODS The authors conducted a blinded, prospective, randomized study comparing key effort and time variables in aneurysm clip ligation surgery with and without preoperative use of the SuRgical Planner (SRP) surgical rehearsal platform. Initially, 40 patients were randomly assigned to either of two groups: one in which surgery was performed after use of the SRP (SRP group) and one in which surgery was performed without use of the SRP (control group). All operations were videotaped. After exclusion of 6 patients from the SRP group and 9 from the control group, a total of 25 surgical cases were analyzed by a reviewer blinded to group assignment. The videos were analyzed for total microsurgical time, number of clips used, and number of clip placement attempts. Means and standard deviations (SDs) were calculated and compared between groups. RESULTS The mean (± SD) amount of operative time per clip used was 920 ± 770 seconds in the SRP group and 1294 ± 678 seconds in the control group (p = 0.05). In addition, the mean values for the number of clip attempts, total operative time, ratio of clip attempts to clips used, and time per clip attempt were all lower in the SRP group, although the between-group differences were not statistically significant. CONCLUSIONS Preoperative rehearsal with SRP increased efficiency and safety in aneurysm microsurgery as demonstrated by the statistically significant improvement in time per clip used. Although the rest of the outcomes did not demonstrate statistically significant between-group differences, the fact that the SRP group showed improvement in mean values for all measures studied suggests that preoperative rehearsal may increase the efficiency and safety of aneurysm microsurgery. Future studies aimed at improving patient outcome and safety during surgical clipping of aneurysms will be needed to keep pace with the quickly advancing endovascular field.
Assessing arsenic and selenium in a single nail clipping using portable X-ray fluorescence.
Fleming, David E B; Nader, Michel N; Foran, Kelly A; Groskopf, Craig; Reno, Michael C; Ware, Chris S; Tehrani, Mina; Guimarães, Diana; Parsons, Patrick J
2017-02-01
The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic K α , selenium K α , arsenic K β , selenium K β , and bromine K α characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the K α peak only, ranged from 0.210±0.002µg/g selenium under one condition of analysis to 0.777±0.009µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important. Copyright © 2016 Elsevier Ltd. All rights reserved.
Singh, Gagan D; Smith, Thomas W; Rogers, Jason H
2017-06-01
The goal of MitraClip therapy is to achieve mitral regurgitation reduction without iatrogenic creation of clinically significant MS. In some series, up to 35% of patients are left with mild MS. There are many contributors to the final transmitral gradient achieved in patients undergoing MitraClip therapy. Additionally, there are many modalities used for the intraprocedural assessment of MS with no one modality considered to be the benchmark. We herein describe a case which illustrates the dynamic nature of clip-leaflet interaction, and review intraprocedural techniques for invasively and noninvasively assessing MS. Copyright © 2016 Elsevier Inc. All rights reserved.
Preparation of digital movie clips for online journal publication.
Yam, Chun-Shan
2006-07-01
This article presents general guidelines for preparing movie clips for online journal publication. As more and more radiology journals establish an online presence, radiologists wishing to submit journal articles with movie clips need to understand the electronic submission process. Viewing a movie clip via an online journal is different from viewing one with PowerPoint using a local desktop computer because the movie file must first be downloaded onto the client computer before it can be displayed. Users thus should be cautious in selecting movie format and compression when creating movie clips for online journals. This article provides step-by-step demonstrations and general guidelines for movie format and compression selections.
NASA Technical Reports Server (NTRS)
Wu, Cathy; Taylor, Pam; Whitson, George; Smith, Cathy
1990-01-01
This paper describes the building of a corn disease diagnostic expert system using CLIPS, and the development of a neural expert system using the fact representation method of CLIPS for automated knowledge acquisition. The CLIPS corn expert system diagnoses 21 diseases from 52 symptoms and signs with certainty factors. CLIPS has several unique features. It allows the facts in rules to be broken down to object-attribute-value (OAV) triples, allows rule-grouping, and fires rules based on pattern-matching. These features combined with the chained inference engine result to a natural user query system and speedy execution. In order to develop a method for automated knowledge acquisition, an Artificial Neural Expert System (ANES) is developed by a direct mapping from the CLIPS system. The ANES corn expert system uses the same OAV triples in the CLIPS system for its facts. The LHS and RHS facts of the CLIPS rules are mapped into the input and output layers of the ANES, respectively; and the inference engine of the rules is imbedded in the hidden layer. The fact representation by OAC triples gives a natural grouping of the rules. These features allow the ANES system to automate rule-generation, and make it efficient to execute and easy to expand for a large and complex domain.
What kind of erotic film clips should we use in female sex research? An exploratory study.
Woodard, Terri L; Collins, Karen; Perez, Mindy; Balon, Richard; Tancer, Manuel E; Kruger, Michael; Moffat, Scott; Diamond, Michael P
2008-01-01
Erotic film clips are used in sex research, including studies of female sexual dysfunction and arousal. However, little is known about which clips optimize female sexual response. Furthermore, their use is not well standardized. To identify the types of film clips that are most mentally appealing and physically arousing to women for use in future sexual function and dysfunction studies; to explore the relationship between mental appeal and reported physical arousal; to characterize the content of the films that were found to be the most and least appealing and arousing. Twenty-one women viewed 90 segments of erotic film clips. They rated how (i) mentally appealing and (ii) how physically aroused they were by each clip. The data were analyzed by descriptive statistics. The means of the mental and self-reported physical responses were calculated to determine the most and least appealing/arousing film clips. Pearson correlations were calculated to assess the relationship between mental appeal and reported physical arousal. Self-reported mental and physical arousal. Of 90 film clips, 18 were identified as the most mentally appealing and physically arousing while nine were identified as the least mentally appealing and physically arousing. The level of mental appeal positively correlated with the level of perceived physical arousal in both categories (r = 0.61, P < 0.05 and r = 0.62, P < 0.05). The most appealing and physically arousing films tended to exhibit heterosexual behavior with vaginal intercourse. The least appealing and least physically arousing films tended to depict male homosexual behavior, fellatio, and anal intercourse. Erotic film clips reliably produced a state of self-reported arousal in women. The most appealing and arousing films tended to depict heterosexual vaginal intercourse. Film clips with these attributes should be used in future research of sexual function and response of women.
Machine-assisted editing of user-generated content
NASA Astrophysics Data System (ADS)
Cremer, Markus; Cook, Randall
2009-02-01
Over recent years user-generated content has become ubiquitously available and an attractive entertainment source for millions of end-users. Particularly for larger events, where many people use their devices to capture the action, a great number of short video clips are made available through appropriate web services. The objective of this presentation is to describe a way to combine these clips by analyzing them, and automatically reconstruct the time line in which the individual video clips were captured. This will enable people to easily create a compelling multimedia experience by leveraging multiple clips taken by different users from different angles, and across different time spans. The user will be able to shift into the role of a movie director mastering a multi-camera recording of the event. To achieve this goal, the audio portion of the video clips is analyzed, and waveform characteristics are computed with high temporal granularity in order to facilitate precise time alignment and overlap computation of the user-generated clips. Special care has to be given not only to the robustness of the selected audio features against ambient noise and various distortions, but also to the matching algorithm used to align the user-generated clips properly.
Duodenal Ulcer Induced by Hem-o-Lok clip after Reduced Port Laparoscopic Cholecystectomy.
Soga, Koichi; Kassai, Kyoichi; Itani, Kenji
2016-03-01
The patient was a 66-year-old woman who had undergone laparoscopic cholecystectomy (Lap-C) secondary to chronic cholecystitis status post endoscopic choledocholithotomy 13 months previously. During surgery, Hem-o-Lok clips were used to control the cystic duct and the cystic artery. Due to the presence of extensive adhesions of the cystic duct and surrounding tissue, the surgeons had difficulty in debriding the area. Thirteen months after Lap-C, the patient underwent a screening esophagogastroduodenoscopy (EGD), which demonstrated clip appearance at the inferior wall of the first part of the duodenum. In the EGD, duodenal erosions and edema were observed around the clip. We appreciated that endoscopic clip removal would be difficult because of the presence of severe adhesions and inflammation of the duodenal bulb. On clinical examination of the patient, no major abnormalities or physical findings were noted. Therefore, we decided not to attempt to remove the clip. The patient was treated with an oral proton pump inhibitor to prevent extensive duodenal mucosal injury. Two months later, we repeated the EGD, which revealed that the clip was no longer present, and the duodenum was covered with normal mucosa surrounding the scar.
Newell, K J; Taylor, B; Walton, J C; Tweedie, E J
2000-01-01
Plastic bread-bag clips have been identified as a cause of local perforation or obstruction at many sites in the gastrointestinal tract. This study is the largest case series yet reported, consisting of 3 cases presenting as small-bowel perforation, 1 case in which the clip was found incidentally in the small bowel at laparotomy during vascular surgery and 1 case in which the clip was found incidentally in the small bowel at autopsy. In all cases there was no radiographic evidence to suggest a foreign body in the gastrointestinal tract. People older than 60 years of age who have either partial or full dentures seem to be particularly at risk for the accidental ingestion of these devices. If accidentally ingested, plastic bread-bag clips represent a significant health hazard. As the population ages, small-bowel perforation secondary to ingestion of such clips may occur with increasing frequency. The authors recommend elimination or redesign of the clips, to prevent their being swallowed and becoming impacted in the small bowel or to allow them to be identified in the gastrointestinal tract by conventional radiography. PMID:10701390
Stanley, Jennifer Tehan; Lohani, Monika; Isaacowitz, Derek M.
2014-01-01
Identifying social gaffes is important for maintaining relationships. Older adults are less able than young to discriminate between socially appropriate and inappropriate behavior in video clips. One open question is how these social appropriateness ratings relate to potential age differences in the perception of what is actually funny or not. In the present study, young, middle-aged, and older adults were equally able to discriminate between appropriate and inappropriate social behavior in a diverse set of clips relevant to both age groups. However, young and middle-aged adults rated the gaffe clips as funnier than control clips and young adults smiled more during the inappropriate clips than the control clips. Older adults did not show this pattern, suggesting that they did not find the inappropriate clips funny. Additionally, young adults endorsed a more aggressive humor style than middle-aged and older adults and aggressive humor style endorsement mediated age differences in social appropriateness ratings. Results are discussed in terms of possible mechanisms such as cohort differences in humor and developmental prioritization of certain humor styles, as well as the importance of investigating age differences in both abilities and preferences. PMID:25244473
Code of Federal Regulations, 2010 CFR
2010-04-01
... ANESTHESIOLOGY DEVICES Miscellaneous § 868.6225 Nose clip. (a) Identification. A nose clip is a device intended to close a patient's external nares (nostrils) during diagnostic or therapeutic procedures. (b... from the current good manufacturing practice requirements of the quality system regulation in part 820...
A CLIPS expert system for clinical flow cytometry data analysis
NASA Technical Reports Server (NTRS)
Salzman, G. C.; Duque, R. E.; Braylan, R. C.; Stewart, C. C.
1990-01-01
An expert system is being developed using CLIPS to assist clinicians in the analysis of multivariate flow cytometry data from cancer patients. Cluster analysis is used to find subpopulations representing various cell types in multiple datasets each consisting of four to five measurements on each of 5000 cells. CLIPS facts are derived from results of the clustering. CLIPS rules are based on the expertise of Drs. Stewart, Duque, and Braylan. The rules incorporate certainty factors based on case histories.
Champagne, C.E.; Austin, J.D.; Jelks, H.L.; Jordan, F.
2008-01-01
Advent of the polymerase chain reaction (PCR) has allowed conservation biologists to use small portions of tissue to obtain genetic material for population genetic and taxonomic study. Fin clips are used extensively in large-sized fishes, but it is unclear how clipping enough fin tissue for genetic analysis will affect survival of smaller fishes such as minnows and darters, which are among the most threatened organisms in North America. We tested for effects of fin clipping on survival and swimming performance of non-threatened Brown Darters (Etheostoma edwini) in order to justify similar tissue collection in co-occurring endangered Okaloosa Darters (E. okaloosae). We collected 48 E. edwini from a small stream in northwest Florida, transported them to the laboratory, and randomly assigned them to one of three experimental groups: control, entire right pectoral fin removed, or rear half of caudal fin removed. Successful amplification of DNA indicated that our fin clips were large enough for genetic analysis using PCR. No mortality occurred during a two-month observation period. Fin regeneration was almost complete and we could not visually distinguish clipped fins from control fins after two months. We then randomly assigned fish into the same three experimental groups, clipped fins, and evaluated their ability to hold position at 20 cm/sec in an experimental flow chamber. Neither fish size nor treatment type affected position-holding behavior. Fin clipping does not adversely affect survival and swimming performance of E. edwini maintained in the laboratory. Additional research on the effects of fin clipping on small-sized fishes should be conducted in the field to evaluate survival under natural conditions. ?? 2008 by the American Society of Ichthyologists and Herpetologists.
Yang, Chang-Ping; Cao, Jin-Lin; Yang, Ren-Rong; Guo, Hong-Rong; Li, Zhao-Hui; Guo, Hai-Ying; Shao, Yin-Can; Liu, Gui-Bao
2014-02-01
Even though laparoscopic cholecystectomy (LC) emerged over 20 years ago, controversies persist with regard to the best method to ligate the cystic duct and artery. We proposed to assess the effectiveness and safety of electrocoagulation to seal the cystic artery and cystic duct after their occlusion with only one absorbable clip. We retrospectively compared the clinical data for 635 patients undergoing LC using electrocoagulation to seal the cystic artery and cystic duct that were occluded with only one absorbable clip (Group 1) and 728 patients undergoing LC using titanium clips (Group 2). In parallel, 30 rabbits randomized into six groups underwent cholecystectomy. After cystic duct ligation with absorbable or titanium clips, the animals were sacrificed 1, 3, or 6 months later, and intraabdominal adhesions were assessed after celiotomy. The mean operative time was significantly shorter (41.6 versus 58.9 minutes, P<.01) in Group 1 than in Group 2. No cystic duct leaks occurred in any patients from Group 1, compared with seven leaks among the 728 (0.96%) patients from Group 2 (P<.05). The morbidity was significantly higher in Group 2 than in Group 1 (3.43% versus 1.58%). Mean intraoperative blood loss and hospitalization length were not significantly different between the two groups, and no deaths occurred in either group. In animal experiments, adhesion was tighter for absorbable than for titanium clips, but fibrous tissue encapsulation was thinner at the site of titanium clips. Electrocoagulation of the cystic artery and cystic duct that were occluded with only one absorbable clip is safe and effective during LC. This approach is associated with shortened operative times and reduced leakage, compared with the standard method using metal clips.
Dujovny, M; Kossovsky, N; Kossowsky, R; Valdivia, R; Suk, J S; Diaz, F G; Berman, S K; Cleary, W
1985-10-01
Because of various mechanical, metallurgical, and commercial constraints, aneurysm clips are manufactured from different alloys, including several stainless steel and cobalt alloys. Some of the steels contain volume fractions of the crystal phase known as martensite. Martensitic alloys have body-centered cubic structure, are prone to stress corrosion failure, and are ferromagnetic. Martensitic steel can be displaced like a compass needle when exposed to a magnetic field such as that generated during magnetic resonance imaging (MRI). The force exerted by the magnetic field is proportional to the volume fraction of the magnetic phase. We investigated the martensitic content and magnetic field-induced displacement of 12 common aneurysm clips. Four clips of each of the following types were examined: Sugita, Sundt-Kees Multi-Angle, Heifetz (two types), Vari-Angle McFadden, Yasargil (two types), Scoville, Mayfield, Vari-Angle, Pivot, and Kapp. Phase homogeneity and crystal structure were analyzed by x-ray diffraction using a Phillips x-ray diffractometer. Clip deflection in an Oxford Research Systems MRI spectrometer was measured in our in vivo rat abdominal aortic aneurysm model. Results showed that the volume fraction of the martensitic phase in the various clips correlated with the magnitude of the deflection. Among the clips examined, the Yasargil, Sugita, Heifetz Elgiloy, and Vari-Angle McFadden had a nonmartensitic composition and did not deflect in the magnetic field. The Scoville contained 5% martensite and deflected only marginally. Martensite comprised 35% of the Mayfield clip, which deflected 45 degrees, and 90% of the Heifetz, Vari-Angle, Pivot, and Sundt-Kees Multi-Angle clips, which deflected approximately 70 degrees or slipped off the aneurysm.(ABSTRACT TRUNCATED AT 250 WORDS)
Intelligent tutoring using HyperCLIPS
NASA Technical Reports Server (NTRS)
Hill, Randall W., Jr.; Pickering, Brad
1990-01-01
HyperCard is a popular hypertext-like system used for building user interfaces to databases and other applications, and CLIPS is a highly portable government-owned expert system shell. We developed HyperCLIPS in order to fill a gap in the U.S. Army's computer-based instruction tool set; it was conceived as a development environment for building adaptive practical exercises for subject-matter problem-solving, though it is not limited to this approach to tutoring. Once HyperCLIPS was developed, we set out to implement a practical exercise prototype using HyperCLIPS in order to demonstrate the following concepts: learning can be facilitated by doing; student performance evaluation can be done in real-time; and the problems in a practical exercise can be adapted to the individual student's knowledge.
Lee, Ziho; Reilly, Christopher E; Moore, Blake W; Mydlo, Jack H; Lee, David I; Eun, Daniel D
2014-01-01
We describe a case in which a Weck Hem-o-lok clip (Teleflex, Research Triangle Park, USA) migrated into the collecting system and acted as a nidus for stone formation in a patient after robot-assisted partial nephrectomy. The patient presented 2 years postoperatively with left-sided renal colic. Abdominal computed tomography scan showed a 10 millimeter renal calculus in the left middle pole. After using laser lithotripsy to fragment the overlying renal stone, a Weck Hem-o-lok clip was found to be embedded in the collecting system. A laser fiber through a flexible ureteroscope was used to successfully dislodge the clip from the renal parenchyma, and a stone basket was used to extract the clip.
40 CFR 60.3078 - What definitions must I know?
Code of Federal Regulations, 2010 CFR
2010-07-01
... shavings. Wood waste does not include: (1) Grass, grass clippings, bushes, shrubs, and clippings from bushes and shrubs from residential, commercial/retail, institutional, or industrial sources as part of..., flake board, and oriented strand board). Yard waste means grass, grass clippings, bushes, shrubs, and...
40 CFR 60.2977 - What definitions must I know?
Code of Federal Regulations, 2010 CFR
2010-07-01
... shavings. Wood waste does not include: (1) Grass, grass clippings, bushes, shrubs, and clippings from bushes and shrubs from residential, commercial/retail, institutional, or industrial sources as part of..., flake board, and oriented strand board). Yard waste means grass, grass clippings, bushes, shrubs, and...
21 CFR 886.3100 - Ophthalmic tantalum clip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... blood vessels in the eye. (b) Classification. Class II (special controls). The device is exempt from the...) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3100 Ophthalmic tantalum clip. (a) Identification. An ophthalmic tantalum clip is a malleable metallic device intended to be implanted permanently...
A graphical interface to CLIPS using SunView
NASA Technical Reports Server (NTRS)
Feagin, Terry
1990-01-01
The importance of the incorporation of various graphics-oriented features into CLIPS is discussed. These popular features, which have been implemented in a version of CLIPS developed for a popular workstation, are described and their usefulness in the development of expert systems is examined.
Bédard, S; Desrochers, A; Fecteau, G; Higgins, R
2001-01-01
This study was designed to evaluate 4 preoperative skin preparations, that is, more specifically, to compare the efficacy of chlorhexidine gluconate (CG) and povidone-iodine (PI), as well as 2 hair removal techniques (clipper alone or clipper followed by razor) for preoperative skin preparation in cattle. The 4 protocols resulted in a significant decrease in the number of bacterial colony-forming units (cfu). Group 4 (clipping + shaving + CG) had a significantly lower number of preoperative cfu per gel plate compared with groups 1 (clipping + PI) and 3 (clipping + shaving + PI). Skin reaction frequency was significantly higher in groups 3 and 4 (47.8% for both protocols) than in groups 1 and 2 (clipping + PI or CG) (8.7% for both). Wound infection frequency was 4.3% (4/92) and no significant difference was observed between the 4 treatment groups. The 4 protocols tested were equivalent as to efficacy and satisfactorily decreased skin microflora. Clipping alone was shown to be preferable to clipping plus shaving as a method of hair removal in cattle, with fewer skin reactions and no more wound infections. PMID:11265188
Ganne, Chaitanya; Talkad, Sathyaprabha N; Srinivas, Dwarakanath; Somanna, Sampath
2016-08-01
In this study, we intend to evaluate the autonomic changes occurring in neurosurgeons and thus the stress during microsurgical clipping of aneurysms. The aim of the current study is to evaluate the heart rate variability (HRV) of the neurosurgeons during microsurgical clipping of aneurysm by using continuous real time monitoring of the ECG intraoperatively. Lead II ECG was recorded using Bioharness(®) (Zephyr Technologies, Annapolis, MD) in 4 healthy neurosurgeons who performed 29 microsurgical clipping of aneurysms. ECG from 21 surgeries was analysed (LabChart(®) software, ADInstruments, Dunedin, New Zealand) across five stages: Baseline (BL), sylvian fissure dissection (SFD), perianeurysmal dissection (PAD), clipping of the aneurysm (CLIP) and haemostasis (HEMO). There was a reduction in TP and an increased LF/HF ratio in spite of suppression of both LF and HF powers. Contrary to the common understanding that the sympathetic limb of the autonomic system mostly mediates responses during stress and anxiety, we found that there was a significant contribution of the parasympathetic system too.
Picard, Fabien; Tadros, Victor-Xavier; Asgar, Anita W
2017-09-01
Edge to edge transcatheter mitral valve repair with MitraClip (Abbott Vascular, Menlo Park, CA) is increasing for high-risk surgical patients with significant mitral regurgitation. Patients with congenitally corrected transposition of the great arteries (CCTGA) presenting with tricuspid valve regurgitation of a systemic right ventricle may represent particularly challenging candidates for MitraClip given their anatomy. We report the case of a 67-year-old gentleman with CCTGA and severe tricuspid regurgitation who was referred for MitraClip implantation after heart team consensus. Successful implantation of one clip was performed, achieving a significant reduction of the regurgitation. Similarly, favorable findings were confirmed at 6 months, 1 and 2 years follow-up and the patient had no recurrent heart failure admissions after 2-year follow-up. We describe the technical considerations and the importance of 3D-transoesophageal echocardiography for performing the MitraClip of a trileaflet systemic atrioventricular valve. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Hill, R. W.
1994-01-01
The integration of CLIPS into HyperCard combines the intuitive, interactive user interface of the Macintosh with the powerful symbolic computation of an expert system interpreter. HyperCard is an excellent environment for quickly developing the front end of an application with buttons, dialogs, and pictures, while the CLIPS interpreter provides a powerful inference engine for complex problem solving and analysis. In order to understand the benefit of integrating HyperCard and CLIPS, consider the following: HyperCard is an information storage and retrieval system which exploits the use of the graphics and user interface capabilities of the Apple Macintosh computer. The user can easily define buttons, dialog boxes, information templates, pictures, and graphic displays through the use of the HyperCard tools and scripting language. What is generally lacking in this environment is a powerful reasoning engine for complex problem solving, and this is where CLIPS plays a role. CLIPS 5.0 (C Language Integrated Production System, v5.0) was developed at the Johnson Space Center Software Technology Branch to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 5.0 supports forward chaining rule systems, object-oriented language, and procedural programming for the construction of expert systems. It features incremental reset, seven conflict resolution stategies, truth maintenance, and user-defined external functions. Since CLIPS is implemented in the C language it is highly portable; in addition, it is embeddable as a callable routine from a program written in another language such as Ada or Fortran. By integrating HyperCard and CLIPS the advantages and uses of both packages are made available for a wide range of applications: rapid prototyping of knowledge-based expert systems, interactive simulations of physical systems and intelligent control of hypertext processes, to name a few. HyperCLIPS 2.0 is written in C-Language (54%) and Pascal (46%) for Apple Macintosh computers running Macintosh System 6.0.2 or greater. HyperCLIPS requires HyperCard 1.2 or higher and at least 2Mb of RAM are recommended to run. An executable is provided. To compile the source code, the Macintosh Programmer's Workshop (MPW) version 3.0, CLIPS 5.0 (MSC-21927), and the MPW C-Language compiler are also required. NOTE: Installing this program under Macintosh System 7 requires HyperCard v2.1. This program is distributed on a 3.5 inch Macintosh format diskette. A copy of the program documentation is included on the diskette, but may be purchased separately. HyperCLIPS was developed in 1990 and version 2.0 was released in 1991. HyperCLIPS is a copyrighted work with all copyright vested in NASA. Apple, Macintosh, MPW, and HyperCard are registered trademarks of Apple Computer, Inc.
Modeling the effect of toe clipping on treefrog survival: Beyond the return rate
Waddle, J.H.; Rice, K.G.; Mazzotti, F.J.; Percival, H.F.
2008-01-01
Some studies have described a negative effect of toe clipping on return rates of marked anurans, but the return rate is limited in that it does not account for heterogeneity of capture probabilities. We used open population mark-recapture models to estimate both apparent survival (ϕ) and the recapture probability (p) of two treefrog species individually marked by clipping 2–4 toes. We used information-theoretic model selection to examine the effect of toe clipping on survival while accounting for variation in capture probability. The model selection results indicate strong support for an effect of toe clipping on survival of Green Treefrogs (Hyla cinerea) and only limited support for an effect of toe clipping on capture probability. We estimate there was a mean absolute decrease in survival of 5.02% and 11.16% for Green Treefrogs with three and four toes removed, respectively, compared to individuals with just two toes removed. Results for Squirrel Treefrogs (Hyla squirella) indicate little support for an effect of toe clipping on survival but may indicate some support for a negative effect on capture probability. We believe that the return rate alone should not be used to examine survival of marked animals because constant capture probability must be assumed, and our examples demonstrate how capture probability may vary over time and among groups. Mark-recapture models provide a method for estimating the effect of toe clipping on anuran survival in situations where unique marks are applied.
Measurement Of The Deformation Of Rail Track Fastening Clips By Holographic Interferometry
NASA Astrophysics Data System (ADS)
Ennos, A. E.
1985-01-01
One method of attaching railway rails to the sleepers (ties) is to use spring steel clips, mounted on either side of the rail, that exert a downward force on the foot of the rail. In service these will flex with the passing of a train. Holographic interferometry has been used to measure quantitatively the manner in which the spring clips deform when the rail is given a displacement in a prescribed direction. The information can be used both to provide data on the bending and torsion of the clip, and as a means of testing the validity of finite element analysis calculations. Measurements on three different designs of commercial clip were carried out on a section of sleeper holding a short length of rail. A controlled upward displacement of the rail was achieved pneumatically by means of plastic pipes interposed between rail and concrete sleeper. Double exposure holograms were recorded on large photographic plates, allowing views of the fringe patterns from widely spaced directions. The three components of displacement at points along the length of the clip were calculated from fringe information taken from nine directions, using least squares fit to obtain increased accuracy. Rotations of the surface were calculated from the fringe directions and spacings. In addition to deformation measurements of the clip under service conditions, information on local yielding of the clip under increasing stress was also obtained by means of real-time interferometry, using an instant hologram camera.
Yatake, Hidetoshi; Sawai, Yuka; Nishi, Toshio; Nakano, Yoshiaki; Nishimae, Ayaka; Katsuda, Toshizo; Yabunaka, Koichi; Takeda, Yoshihiro; Inaji, Hideo
2017-07-01
The objective of the study was to compare direct measurement with a conventional method for evaluation of clip placement in stereotactic vacuum-assisted breast biopsy (ST-VAB) and to evaluate the accuracy of clip placement using the direct method. Accuracy of clip placement was assessed by measuring the distance from a residual calcification of a targeted calcification clustered to a clip on a mammogram after ST-VAB. Distances in the craniocaudal (CC) and mediolateral oblique (MLO) views were measured in 28 subjects with mammograms recorded twice or more after ST-VAB. The difference in the distance between the first and second measurements was defined as the reproducibility and was compared with that from a conventional method using a mask system with overlap of transparent film on the mammogram. The 3D clip-to-calcification distance was measured using the direct method in 71 subjects. The reproducibility of the direct method was higher than that of the conventional method in CC and MLO views (P = 0.002, P < 0.001). The median 3D clip-to-calcification distance was 2.8 mm, with an interquartile range of 2.0-4.8 mm and a range of 1.1-36.3 mm. The direct method used in this study was more accurate than the conventional method, and gave a median 3D distance of 2.8 mm between the calcification and clip.
Caudill, Cassie L; Perry, Jillian L; Tian, Shaomin; Luft, J Christopher; DeSimone, Joseph M
2018-06-09
Microneedle patches, arrays of micron-scale projections that penetrate skin in a minimally invasive manner, are a promising tool for transdermally delivering therapeutic proteins. However, current microneedle fabrication techniques are limited in their ability to fabricate microneedles rapidly and with a high degree of control over microneedle design parameters. We have previously demonstrated the ability to fabricate microneedle patches with a range of compositions and geometries using the novel additive manufacturing technique Continuous Liquid Interface Production (CLIP). Here, we establish a method for dip coating CLIP microneedles with protein cargo in a spatially controlled manner. Microneedle coating mask devices were fabricated with CLIP and utilized to coat polyethylene glycol-based CLIP microneedles with model proteins bovine serum albumin, ovalbumin, and lysozyme. The design of the coating mask device was used to control spatial deposition and loading of coated protein cargo on the microneedles. CLIP microneedles rapidly released coated protein cargo both in solution and upon insertion into porcine skin. The model enzyme lysozyme was shown to retain its activity throughout the CLIP microneedle coating process, and permeation of bovine serum albumin across full thickness porcine skin was observed after application with coated CLIP microneedles. Protein-coated CLIP microneedles were applied to live mice and showed sustained retention of protein cargo in the skin over 72 h. These results demonstrate the utility of a versatile coating platform for preparation of precisely coated microneedles for transdermal therapeutic delivery. Copyright © 2018. Published by Elsevier B.V.
Impulsivity Moderates the Effects of Movie Alcohol Portrayals on Adolescents’ Willingness to Drink
Gibbons, Frederick X.; Kingsbury, John H.; Wills, Thomas A.; Finneran, Stephanie D.; Cin, Sonya Dal; Gerrard, Meg
2016-01-01
This study examined impulsivity as a moderator of adolescents’ reactions to positive vs. negative portrayals of drinking in American movie clips. Impulsivity, along with willingness and intentions to drink in the future, were assessed in a pretest session. In the experimental sessions, adolescents viewed a series of clips that showed drinking associated with either positive outcomes (e.g., social facilitation) or negative outcomes (fights, arguments). A third group viewed clips with similar positive or negative outcomes, but no alcohol consumption. All participants then responded to an implicit measure of attentional bias regarding alcohol (a dot probe), followed by explicit alcohol measures (self-reports of willingness and intentions to drink). Hypotheses, based on dual-processing theories, were: a) high-impulsive adolescents would respond more favorably than low-impulsive adolescents to the positive clips, but not the negative clips; and b) this difference in reactions to the positive clips would be larger on the willingness than the intention measures. Results supported the hypotheses: Adolescents high in impulsivity reported the highest willingness to drink in the positive-clip condition, but were slightly less willing than others in the negative-clip condition. In addition, results on the dot probe task indicated that reaction times to alcohol words were negatively correlated with changes in alcohol willingness, but not intention; i.e., the faster their response to the alcohol words, the more their willingness increased. The results highlight the utility of a dual-processing perspective on media influence. PMID:27099959
NASA Astrophysics Data System (ADS)
Michel, Robert G.; Cavallari, Jennifer M.; Znamenskaia, Elena; Yang, Karl X.; Sun, Tao; Bent, Gary
1999-12-01
This article is an electronic publication in Spectrochimica Acta Electronica (SAE), a section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by an electronic archive, stored on the CD-ROM accompanying this issue. The archive contains video clips. The main article discusses the scientific aspects of the subject and explains the purpose of the video files. Short, 15-30 s, digital video clips are easily controllable at the computer keyboard, which gives a speaker the ability to show fine details through the use of slow motion. Also, they are easily accessed from the computer hard drive for rapid extemporaneous presentation. In addition, they are easily transferred to the Internet for dissemination. From a pedagogical point of view, the act of making a video clip by a student allows for development of powers of observation, while the availability of the technology to make digital video clips gives a teacher the flexibility to demonstrate scientific concepts that would otherwise have to be done as 'live' demonstrations, with all the likely attendant misadventures. Our experience with digital video clips has been through their use in computer-based presentations by undergraduate and graduate students in analytical chemistry classes, and by high school and middle school teachers and their students in a variety of science and non-science classes. In physics teaching laboratories, we have used the hardware to capture digital video clips of dynamic processes, such as projectiles and pendulums, for later mathematical analysis.
Dellaretti, Marcos; da Silva Martins, Warley Carvalho; Dourado, Jules Carlos; Faglioni, Wilson; Quadros, Ricardo Souza; de Souza Moraes, Vítor Vieira; de Souza Filho, Carlos Batista Alves
2017-01-01
Background: Despite new techniques for the treatment of cerebral aneurysms, the percentage of aneurysm remnants after surgical intervention seems to be relatively constant. The objective of this study was to assess angiographic and epidemiological features associated with aneurysm remnants after microsurgical clipping. Methods: This study was conducted from February 2009 to August 2012 on a series of 90 patients with 105 aneurysms referred to the Santa Casa of Belo Horizonte who were surgically treated and angiographically controlled. Results: Surgical clipping was considered incomplete in 13.3% of the aneurysms. The mean age of cases with an aneurysm remnant was 57.5 years, whereas the mean age without aneurysm remnant was 49.7 years (P = 0.02). Aneurysm remnants were detected more frequently on the internal carotid artery, nevertheless, no statistically significant differences were verified when comparing the locations. Aneurysm size in the preoperative angiography verified that the mean size of aneurysms operated was 6.56 mm, such that in cases showing a postoperative remnant, the mean size was 9.7 mm and in cases with complete clipping it was 6.08 mm (P = 0.02). Postoperative angiography showed that, in cases with residual aneurysm, the number of clips used was higher – a mean of 1.8 for complete clipping and 3.1 for incomplete clipping (P < 0.001). Conclusions: Aneurysm size and patient age showed significant correlations with residual intracranial aneurysm. The mean number of clips used was higher in cases with incomplete occlusion. PMID:28904825
Impact of Oncoming Headlight Glare With Cataracts: A Pilot Study
Hwang, Alex D.; Tuccar-Burak, Merve; Goldstein, Robert; Peli, Eli
2018-01-01
Purpose: Oncoming headlight glare (HLG) reduces the visibility of objects on the road and may affect the safety of nighttime driving. With cataracts, the impact of oncoming HLG is expected to be more severe. We used our custom HLG simulator in a driving simulator to measure the impact of HLG on pedestrian detection by normal vision subjects with simulated mild cataracts and by patients with real cataracts. Methods: Five normal vision subjects drove nighttime scenarios under two HLG conditions (with and without HLG: HLGY and HLGN, respectively), and three vision conditions (with plano lens, simulated mild cataract, and optically blurred clip-on). Mild cataract was simulated by applying a 0.8 Bangerter diffusion foil to clip-on plano lenses. The visual acuity with the optically blurred lenses was individually chosen to match the visual acuity with the simulated cataract clip-ons under HLGN. Each nighttime driving scenario contains 24 pedestrian encounters, encompassing four pedestrian types; walking along the left side of the road, walking along the right side of the road, crossing the road from left to right, and crossing the road from right to left. Pedestrian detection performances of five patients with mild real cataracts were measured using the same setup. The cataract patients were tested only in HLGY and HLGN conditions. Participants’ visual acuity and contrast sensitivity were also measured in the simulator with and without stationary HLG. Results: For normal vision subjects, both the presence of oncoming HLG and wearing the simulated cataract clip-on reduced pedestrian detection performance. The subjects performed worst in events where the pedestrian crossed from the left, followed by events where the pedestrian crossed from the right. Significant interactions between HLG condition and other factors were also found: (1) the impact of oncoming HLG with the simulated cataract clip-on was larger than with the plano lens clip-on, (2) the impact of oncoming HLG was larger with the optically blurred clip-on than with the plano lens clip-on, but smaller than with the simulated cataract clip-on, and (3) the impact was larger for the pedestrians that crossed from the left than those that crossed from the right, and for the pedestrians walking along the left side of the road than walking along the right side of the road, suggesting that the pedestrian proximity to the glare source contributed to the performance reduction. Under HLGN, almost no pedestrians were missed with the plano lens or the simulated cataract clip-on (0 and 0.5%, respectively), but under HLGY, the rate of pedestrian misses increased to 0.5 and 6%, respectively. With the optically blurred clip-on, the percent of missed pedestrians under HLGN and HLGY did not change much (5% and 6%, respectively). Untimely response rate increased under HLGY with the plano lens and simulated cataract clip-ons, but the increase with the simulated cataract clip-on was significantly larger than with the plano lens clip-on. The contrast sensitivity with the simulated cataract clip-on was significantly degraded under HLGY. The visual acuity with the plano lens clip-on was significantly improved under HLGY, possibly due to pupil myosis. The impact of HLG measured for real cataract patients was similar to the impact on performance of normal vision subjects with simulated cataract clip-ons. Conclusion: Even with mild (simulated or real) cataracts, a substantial negative effect of oncoming HLG was measurable in the detection of crossing and walking-along pedestrians. The lowered pedestrian detection rates and longer response times with HLGY demonstrate a possible risk that oncoming HLG poses to patients driving with cataracts. PMID:29559933
Modeling Current Transfer from PV Modules Based on Meteorological Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hacke, Peter; Smith, Ryan; Kurtz, Sarah
2016-11-21
Current transferred from the active cell circuit to ground in modules undergoing potential-induced degradation (PID) stress is analyzed with respect to meteorological data. Duration and coulombs transferred as a function of whether the module is wet (from dew or rain) or the extent of uncondensed surface humidity are quantified based on meteorological indicators. With this, functions predicting the mode and rate of coulomb transfer are developed for use in estimating the relative PID stress associated with temperature, moisture, and system voltage in any climate. Current transfer in a framed crystalline silicon module is relatively high when there is no condensedmore » water on the module, whereas current transfer in a thin-film module held by edge clips is not, and displays a greater fraction of coulombs transferred when wet compared to the framed module in the natural environment.« less
21 CFR 882.4200 - Clip removal instrument.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip removal instrument. 882.4200 Section 882.4200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4200 Clip removal instrument. (a...
21 CFR 882.4175 - Aneurysm clip applier.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a...
21 CFR 882.5225 - Implanted malleable clip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implanted malleable clip. 882.5225 Section 882.5225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5225 Implanted malleable clip...
21 CFR 882.4190 - Clip forming/cutting instrument.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip forming/cutting instrument. 882.4190 Section 882.4190 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4190 Clip forming...
21 CFR 882.5225 - Implanted malleable clip.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Implanted malleable clip. 882.5225 Section 882.5225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5225 Implanted malleable clip...
21 CFR 882.4175 - Aneurysm clip applier.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a...
21 CFR 882.5200 - Aneurysm clip.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm...
21 CFR 882.5200 - Aneurysm clip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm...
21 CFR 882.4200 - Clip removal instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip removal instrument. 882.4200 Section 882.4200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4200 Clip removal instrument. (a...
21 CFR 870.3250 - Vascular clip.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vascular clip. 870.3250 Section 870.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3250 Vascular clip. (a) Identification. A vascular...
21 CFR 870.3250 - Vascular clip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vascular clip. 870.3250 Section 870.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3250 Vascular clip. (a) Identification. A vascular...
Implementing a frame representation in CLIPS/COOL
NASA Technical Reports Server (NTRS)
Myers, Leonard; Snyder, James
1991-01-01
An implementation is described and evaluated of frames in COOL. The test case is a frame based semantic network previously implemented in CLIPS (C Language Integrated Production System) Version 4.3 as part of the Intelligent Computer Aided Design System (ICADS) and reported at the first CLIPS conference.
21 CFR 878.4300 - Implantable clip.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...
21 CFR 878.4300 - Implantable clip.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...
21 CFR 878.4300 - Implantable clip.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...
21 CFR 878.4300 - Implantable clip.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...
21 CFR 878.4300 - Implantable clip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...
Buchholz, Vered; Sadot, Eran; Spivak, Hadar
2015-08-01
Intracorporeal suturing is time-consuming and could be difficult in certain operative circumstances. Instead of knot tying, specially designed clips have been introduced to anchor and secure the end of a single strand or suture. Although these clips provide a maximal required holding grip (HG), they considerably increase the cost of the procedure. The aim of this in vitro study was to identify the feasibility, and means of achieving the best HG, of commonly used disposable automatic clip appliers (LCAs) over regular strands. We placed 2-0 PDS (rigid) and 2-0 Vicryl (soft) sutures through fresh gastric wall specimens. Six different commercial-type LCAs, all having large or medium/large clips, were applied at the distal end of each suture. An IMDA manual digital force gauge was used to measure the HG of each clip at 2 positions: the middle clip position and the angle (at the crouch) position. A total of 192 measurements were taken. The results were classified into 3 HG levels measured by Newton units (N): the strongest grip (> 1 N), medium grip (> 0.5 and < 1 N), and weak grip (< 0.5 N). The strongest HG was obtained by applying 10 to 12 mm LCAs with large or medium/large clips over PDS at an angle position (HG = 1.1 ± 0.2 to 1.6 ± 0.3 N). The weakest grip was obtained by applying any type of LCA over Vicryl at the middle position (HG = 0.08 ± 0.04 to 0.2 ± 0.06 N, P < 0.001). The latter was associated with clips freely falling off the sutures even before applying any force. In general, more force was needed to dislodge any brand clip from the PDS compared with Vicryl suture (0.8 ± 0.6 vs. 0.4 ± 0.3 N, P < 0.001). The angle position was always stronger than the middle position (0.9 ± 0.6 vs. 0.3 ± 0.2 N, P < 0.001). There was a trend for the 10 to 12 mm LCA to have a better HG than the 5 mm ones (0.65 ± 0.5 vs. 0.51 ± 0.5 N, P = 0.08). We propose that 10 to 12 mm LCAs generate enough HG to secure a single strand when clips are placed at the angle position. This is especially true over PDS (hard) strands. The application of 5 mm LCA clips to secure the end of the Vicryl strand is not recommended. Further clinical studies are warranted.
Chinese Language Video Clips. [CD-ROM].
ERIC Educational Resources Information Center
Fleming, Stephen; Hipley, David; Ning, Cynthia
This compact disc includes video clips covering six topics for the learner of Chinese: personal information, commercial transactions, travel and leisure, health and sports, food and school. Filmed on location in Beijing, these naturalistic video clips consist mainly of unrehearsed interviews of ordinary people. The learner is lead through a series…
21 CFR 870.3260 - Vena cava clip.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...
A Simple Recipe for Whitening Old Newspaper Clippings.
ERIC Educational Resources Information Center
Carter, Henry A.
1995-01-01
Describes a method for experimenting with both whitening and deacidifying old newspaper clippings using sodium borohydride bleaching. Clippings are soaked in distilled water then immersed in sodium borohydride for 15-20 minutes. After rinsing with distilled water, the paper is washed with saturated Ca(OH)2 solution. Readers should not begin…
Understanding and Applying Psychology through Use of News Clippings.
ERIC Educational Resources Information Center
Rider, Elizabeth A.
1992-01-01
Discusses a student project for psychology courses in which students collect newspaper clippings that illustrate psychological concepts. Explains that the students record the source and write a brief description of the clipping, explaining how it relates to a psychological concept or theory. Includes results of student evaluations of the…
21 CFR 882.4190 - Clip forming/cutting instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip forming/cutting instrument. 882.4190 Section 882.4190 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES.../cutting instrument. (a) Identification. A clip forming/cutting instrument is a device used by the...
21 CFR 870.3260 - Vena cava clip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...
DOT National Transportation Integrated Search
2007-05-01
Subjects rated the workload of clips of forward road scenes (from the advanced collision avoidance system (ACAS) field operational test) in relation to 2 anchor clips of Level of Service (LOS) A and E (light and heavy traffic), and indicated if they ...
21 CFR 878.4320 - Removable skin clip.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...
21 CFR 878.4320 - Removable skin clip.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...
21 CFR 878.4320 - Removable skin clip.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...
21 CFR 878.4320 - Removable skin clip.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...
Constructing complex graphics applications with CLIPS and the X window system
NASA Technical Reports Server (NTRS)
Faul, Ben M.
1990-01-01
This article will demonstrate how the artificial intelligence concepts in CLIPS used to solve problems encountered in the design and implementation of graphics applications within the UNIX-X Window System environment. The design of an extended version of CLIPS, called XCLIPS, is presented to show how the X Windows System graphics can be incorporated without losing DOS compatibility. Using XCLIPS, a sample scientific application is built that applies solving capabilities of both two and three dimensional graphics presentations in conjunction with the standard CLIPS features.
Attaching solar collectors to a structural framework utilizing a flexible clip
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruse, John S
Methods and apparatuses described herein provide for the attachment of solar collectors to a structural framework in a solar array assembly. A flexible clip is attached to either end of each solar collector and utilized to attach the solar collector to the structural framework. The solar collectors are positioned to allow a member of the framework to engage a pair of flexible clips attached to adjacent solar collectors during assembly of the solar array. Each flexible clip may have multiple frame-engaging portions, each with a flange on one end to cause the flexible clip to deflect inward when engaged bymore » the framework member during assembly and to guide each of the frame-engaging portions into contact with a surface of the framework member for attachment.« less
The Use of Film Clips in a Viewing Time Task of Sexual Interests.
Lalumière, Martin L; Babchishin, Kelly M; Ebsworth, Megan
2018-04-01
Viewing time tasks using still pictures to assess age and gender sexual interests have been well validated and are commonly used. The use of film clips in a viewing time task would open up interesting possibilities for the study of sexual interest toward sexual targets or activities that are not easily captured in still pictures. We examined the validity of a viewing time task using film clips to assess sexual interest toward male and female targets, in a sample of 52 young adults. Film clips produced longer viewing times than still pictures. For both men and women, the indices derived from the film viewing time task were able to distinguish individuals who identified as homosexual (14 men, 8 women) from those who identified as heterosexual (15 men, 15 women), and provided comparable group differentiation as indices derived from a viewing time task using still pictures. Men's viewing times were more gender-specific than those of women. Viewing times to film clips were correlated with participants' ratings of sexual appeal of the same clips, and with viewing times to pictures. The results support the feasibility of a viewing time measure of sexual interest that utilizes film clips and, thus, expand the types of sexual interests that could be investigated (e.g., sadism, biastophilia).
Zheng, Cong Cong; Wang, Yong Jing; Sun, Hao; Wang, Xin Yu; Gao, Ying Zhi
2017-07-18
Soil salinization and overgrazing are two main factors limiting animal husbandry in the Songnen Grassland. Leymus chinensis is a dominant rhizome grass, resistant to grazing as well as to-lerant to salt stress. Foliar labeled with 15 N-urea was used to study the nitrogen allocation strategy and compensatory growth response to clipping under saline-alkali conditions. The results showed that the total absorbed 15 N allocated to the aboveground part was more than 60%. Compared with the control treatment (no saline-alkali, no clipping), saline-alkali increased the distribution of 15 N by 5.1% in root; the 15 N distribution into aboveground in the moderate clipping and saline-alkali treatment was 11.6% higher than that of the control, exhibiting over-compensatory growth of aboveground biomass and total biomass, however, 15 N allocated to stem base was significantly increased by 9.5% under severe clipping level and saline-alkali addition, showing under-compensatory growth of shoot, root and total biomass. These results suggested that L. chinensis adapted to mode-rate clipping by over-compensatory growth under salt-alkali stress condition. However, L. chinensis would take a relatively conservative growth strategy through the enhanced N allocation to stem base for storage under severe saline-alkali and clipping conditions.
Acquisition and processing pitfall with clipped traces in surface-wave analysis
NASA Astrophysics Data System (ADS)
Gao, Lingli; Pan, Yudi
2016-02-01
Multichannel analysis of surface waves (MASW) is widely used in estimating near-surface shear (S)-wave velocity. In the MASW method, generating a reliable dispersion image in the frequency-velocity (f-v) domain is an important processing step. A locus along peaks of dispersion energy at different frequencies allows the dispersion curves to be constructed for inversion. When the offsets are short, the output seismic data may exceed the dynamic ranges of geophones/seismograph, as a result of which, peaks and (or) troughs of traces will be squared off in recorded shot gathers. Dispersion images generated by the raw shot gathers with clipped traces would be contaminated by artifacts, which might be misidentified as Rayleigh-wave phase velocities or body-wave velocities and potentially lead to incorrect results. We performed some synthetic models containing clipped traces, and analyzed amplitude spectra of unclipped and clipped waves. The results indicate that artifacts in the dispersion image are dependent on the level of clipping. A real-world example also shows how clipped traces would affect the dispersion image. All the results suggest that clipped traces should be removed from the shot gathers before generating dispersion images, in order to pick accurate phase velocities and set reasonable initial inversion models.
Assessment of a simple, novel endoluminal method for gastrotomy closure in NOTES.
Lee, Sang Soo; Oelschlager, Brant K; Wright, Andrew S; Soares, Renato V; Sinan, Huseyin; Montenovo, Martin I; Hwang, Joo Ha
2011-10-01
A reliable method for gastrotomy closure in NOTES will be essential for NOTES to become viable clinically. However, methods using existing and widely available endoscopic accessories have been ineffective. The objective of this study was to evaluate the feasibility and safety of a new simple method for gastric closure (retracted clip-assisted loop closure) that uses existing endoscopic accessories with minor modifications. The retracted clip-assisted loop closure technique involves deploying 3-4 Resolution(®) clips (modified by attaching a 90-cm length of suture to the end of each clip) along the margin of the gastrotomy with one jaw on the serosal surface and the other jaw on the mucosal surface. The suture strings are threaded through an endoloop. Traction is then applied to the strings causing the gastric wall to tent. The endoloop is secured below the tip of the clips, completing a full-thickness gastrotomy closure. The main outcome measures were feasibility, efficacy, and safety of the new retracted clip-assisted loop closure technique for NOTES gastrotomy closure. An air-tight seal was achieved in 100% (n = 9) of stomachs. The mean leak pressure was 116.3 (±19.4) mmHg. The retracted clip-assisted loop closure technique can be used to perform NOTES gastrotomy closure by using existing endoscopic accessories with minor modifications.
Martino, Steven C.; Haviland, Amelia; Setodji, Claude; Primack, Brian A.
2010-01-01
Introduction: Exposure to smoking in movies is strongly associated with smoking uptake and maintenance among adolescents. However, little is known about what features of movies (e.g., the context for smoking or motives for a character smoking) moderate the association between exposure to movie smoking and adolescent smoking. This laboratory study examined whether exposure to movie smoking that is portrayed as having a clear motive is associated with the desire to smoke differently than smoking that is portrayed as having no clear motive. Methods: A sample of 77 middle school students (mean age of 12.8 years, 62% male, 60% Caucasian) viewed movie clips that portrayed smoking as helping to facilitate social interaction, to relax, to appear rebellious, or as having no clear motive. After exposure to each clip, participants rated their desire to smoke. Results: Exposure to clips where smoking was portrayed as helping characters to relax was associated with a significantly stronger desire to smoke compared with clips where the motive for smoking was unclear. Desire to smoke was similar for clips where no motive was clear, social smoking clips, and rebellious smoking clips. Discussion: These results suggest that the way that smoking is portrayed in movies is important in determining its effect on adolescent smoking. PMID:20576800
Shadel, William G; Martino, Steven C; Haviland, Amelia; Setodji, Claude; Primack, Brian A
2010-08-01
Exposure to smoking in movies is strongly associated with smoking uptake and maintenance among adolescents. However, little is known about what features of movies (e.g., the context for smoking or motives for a character smoking) moderate the association between exposure to movie smoking and adolescent smoking. This laboratory study examined whether exposure to movie smoking that is portrayed as having a clear motive is associated with the desire to smoke differently than smoking that is portrayed as having no clear motive. A sample of 77 middle school students (mean age of 12.8 years, 62% male, 60% Caucasian) viewed movie clips that portrayed smoking as helping to facilitate social interaction, to relax, to appear rebellious, or as having no clear motive. After exposure to each clip, participants rated their desire to smoke. Exposure to clips where smoking was portrayed as helping characters to relax was associated with a significantly stronger desire to smoke compared with clips where the motive for smoking was unclear. Desire to smoke was similar for clips where no motive was clear, social smoking clips, and rebellious smoking clips. These results suggest that the way that smoking is portrayed in movies is important in determining its effect on adolescent smoking.
Carlson, Joshua M.; Rubin, Denis; Cha, Jiook; Mujica-Parodi, Lilianne
2015-01-01
The neural correlates of anxious anticipation have been primarily studied with aversive and neutral stimuli. In this study, we examined the effect of valence on anticipation by using high arousal aversive and positive stimuli and a condition of uncertainty (i.e. either positive or aversive). The task consisted of predetermined cues warning participants of upcoming aversive, positive, ‘uncertain’ (either aversive or positive) and neutral movie clips. Anticipation of all affective clips engaged common regions including the anterior insula, dorsal anterior cingulate cortex, thalamus, caudate, inferior parietal and prefrontal cortex that are associated with emotional experience, sustained attention and appraisal. In contrast, the nucleus accumbens and medial prefrontal cortex, regions implicated in reward processing, were selectively engaged during anticipation of positive clips (depicting sexually explicit content) and the mid-insula, which has been linked to processing aversive stimuli, was selectively engaged during anticipation of aversive clips (depicting graphic medical procedures); these three areas were also activated during anticipation of ‘uncertain’ clips reflecting a broad preparatory response for both aversive and positive stimuli. These results suggest that a common circuitry is recruited in anticipation of affective clips regardless of valence, with additional areas preferentially engaged depending on whether expected stimuli are negative or positive. PMID:24984958
The utility of dual-energy CT for metal artifact reduction from intracranial clipping and coiling.
Mera Fernández, D; Santos Armentia, E; Bustos Fiore, A; Villanueva Campos, A M; Utrera Pérez, E; Souto Bayarri, M
2018-04-23
To assess the ability of dual-energy CT (DECT) to reduce metal-related artifacts in patients with clips and coils in head CT angiography, and to analyze the differences in this reduction between both type of devices. Thirteen patients (6 clips, 7 coils) were selected and retrospectively analized. Virtual monoenergetic images (MEI) with photon energies from 40 to 150 keV were obtained. Noise was measured at the area of maximum artifact. Subjective evaluation of streak artifact was performed by two radiologists independently. Differences between noise values in all groups were tested by using the ANOVA test. Mann-Whitney U test was used to compare the differences between clips and coils. Coheńs κ statistic was used to determine interobserver agreement. The lowest noise value was observed at high energy levels (p<0,05). Noise was higher in the coil group than in the clip group (p<0.001). Interobserver agreement was good (κ=0.72). TCED with MEI helps to minimize the artifact from clips ands coils in patients who undergo head CT angiography. The reduction of the artifact is greater in patients with surgical clipping than in patients with endovascular coiling. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Sympathetic block by metal clips may be a reversible operation.
Thomsen, Lars L; Mikkelsen, Rasmus T; Derejko, Miroslawa; Schrøder, Henrik D; Licht, Peter B
2014-12-01
Thoracoscopic sympathectomy is now used routinely to treat patients with disabling primary hyperhidrosis or facial blushing. Published results are excellent, but side effects, such as compensatory sweating, are also very frequent. The surgical techniques used and the levels of targeting the sympathetic chain vary tremendously. Most surgeons transect or resect the sympathetic chain, but application of a metal clip that blocks transmission of nerve impulses in the sympathetic chain is used increasingly worldwide. This approach offers potential reversibility if patients regret surgery, but the question of reversibility remains controversial. Two recent experimental studies found severe histological signs of nerve damage 4-6 weeks after clip removal, but they only used conventional histopathological staining methods. Thoracoscopic clipping of the sympathetic trunk was performed in adult sheep, and the clip was removed thoracoscopically after 7 days. Following another 4 weeks (n = 6) or 12 weeks (n = 3), the sympathetic trunks were harvested and analysed by conventional and specific nerve tissue immunohistochemical stains (S100, neurofilament protein and synaptophysin). The contralateral sympathetic chains were used as controls. Conventional and immunohistochemical stains demonstrated severe signs of neural damage on the operated side 4 weeks after clip removal. After 12 weeks, these changes had decreased markedly and conventional histology had almost normalized. Conventional and immunohistochemical stains confirmed that application of metal clips to the sympathetic chain caused severe histological damage in the sympathetic trunk that remained visible 4 weeks after clip removal. However, after 12 weeks, these signs of damage had clearly decreased, which suggests in theory that application of metal clips to the sympathetic chain is a reversible procedure if only the observation period is prolonged. Further studies with longer periods between application and removal as well as investigations of nerve conduction should be encouraged, because we do not know whether histological reversibility at cellular level translates into physiological reversibility and possible correlation of nerve trauma with the duration of the applied clip. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
CLIPS, AppleEvents, and AppleScript: Integrating CLIPS with commercial software
NASA Technical Reports Server (NTRS)
Compton, Michael M.; Wolfe, Shawn R.
1994-01-01
Many of today's intelligent systems are comprised of several modules, perhaps written in different tools and languages, that together help solve the user's problem. These systems often employ a knowledge-based component that is not accessed directly by the user, but instead operates 'in the background' offering assistance to the user as necessary. In these types of modular systems, an efficient, flexible, and eady-to-use mechanism for sharing data between programs is crucial. To help permit transparent integration of CLIPS with other Macintosh applications, the AI Research Branch at NASA Ames Research Center has extended CLIPS to allow it to communicate transparently with other applications through two popular data-sharing mechanisms provided by the Macintosh operating system: Apple Events (a 'high-level' event mechanism for program-to-program communication), and AppleScript, a recently-released scripting language for the Macintosh. This capability permits other applications (running on either the same or a remote machine) to send a command to CLIPS, which then responds as if the command were typed into the CLIPS dialog window. Any result returned by the command is then automatically returned to the program that sent it. Likewise, CLIPS can send several types of Apple Events directly to other local or remote applications. This CLIPS system has been successfully integrated with a variety of commercial applications, including data collection programs, electronics forms packages, DBMS's, and email programs. These mechanisms can permit transparent user access to the knowledge base from within a commercial application, and allow a single copy of the knowledge base to service multiple users in a networked environment.
TOYOTA, Shingo; TAKI, Takuyu; WAKAYAMA, Akatsuki; YOSHIMINE, Toshiki
2015-01-01
Internal carotid-posterior communicating artery (IC-PC) aneurysms account for more than 20% of all intracranial aneurysms. As a result of the increase in coiling, there has also been an increase in recurrent IC-PC aneurysms after coiling. We present our experience of 10 recurrent IC-PC aneurysms after coiling that were retreated using surgical or endovascular techniques in order to discuss the choice of treatment and the points of clipping without removal of coils. From 2007 to 2014, 10 recurrent IC-PC aneurysms after coiling were retreated. When the previous frames covered the aneurysms all around or almost around except a part of the neck, coiling was chosen. In other cases, clipping was chosen. Clipping was attempted without removal of coils when it was technically feasible. Among the 10 IC-PC aneurysms retreated, 3 were retreated with coiling and 7 were retreated with clipping. In all three cases retreated with coiling, almost complete occlusion was accomplished. In the seven cases retreated with clipping, coil extrusion was observed during surgery in six cases. In most of them, it was necessary to dissect strong adhesions around the coiled aneurysms and to utilize temporary occlusion of the internal carotid artery. In all seven cases, neck clipping was accomplished without the removal of coils. There were no neurological complications in any cases. The management of recurrent lesions of embolized IC-PC aneurysms requires appropriate choice of treatment using both coiling and clipping. Clipping, especially without the removal of coils, plays an important role in safe treatment. PMID:26437796
Toyota, Shingo; Taki, Takuyu; Wakayama, Akatsuki; Yoshimine, Toshiki
2015-01-01
Internal carotid-posterior communicating artery (IC-PC) aneurysms account for more than 20% of all intracranial aneurysms. As a result of the increase in coiling, there has also been an increase in recurrent IC-PC aneurysms after coiling. We present our experience of 10 recurrent IC-PC aneurysms after coiling that were retreated using surgical or endovascular techniques in order to discuss the choice of treatment and the points of clipping without removal of coils. From 2007 to 2014, 10 recurrent IC-PC aneurysms after coiling were retreated. When the previous frames covered the aneurysms all around or almost around except a part of the neck, coiling was chosen. In other cases, clipping was chosen. Clipping was attempted without removal of coils when it was technically feasible. Among the 10 IC-PC aneurysms retreated, 3 were retreated with coiling and 7 were retreated with clipping. In all three cases retreated with coiling, almost complete occlusion was accomplished. In the seven cases retreated with clipping, coil extrusion was observed during surgery in six cases. In most of them, it was necessary to dissect strong adhesions around the coiled aneurysms and to utilize temporary occlusion of the internal carotid artery. In all seven cases, neck clipping was accomplished without the removal of coils. There were no neurological complications in any cases. The management of recurrent lesions of embolized IC-PC aneurysms requires appropriate choice of treatment using both coiling and clipping. Clipping, especially without the removal of coils, plays an important role in safe treatment.
Zirconia-Polyurethane Aneurysm Clip.
Cho, Won-Sang; Cho, Kyung-Il; Kim, Jeong Eun; Jang, Tae-Sik; Ha, Eun Jin; Kang, Hyun-Seung; Son, Young-Je; Choi, Seung Hong; Lee, Seunghyun; Kim, Chong-Chan; Sun, Jeong-Yun; Kim, Hyoun-Ee
2018-03-27
Susceptibility artifacts from metal clips in magnetic resonance (MR) imaging present an obstacle to evaluating the status of clipped aneurysms, parent arteries and adjacent brain parenchyma. We aimed to develop MR-compatible aneurysm clips. Considering the mechanical and biological properties, and MR compatibility of candidate materials, a prototype clip with a zirconia body and a polyurethane head spring (ZC, straight, 9-mm long) was developed. The closing forces, opening width of blades, and in vitro and in vivo artifact volumes in 3 tesla MR imaging were compared among the prototype and commercial metal clips such as a Yasargil ® clip (YC, curved type, 8.3-mm long) and a Sugita ® clip (SC, straight type, 10-mm long). An in vivo animal study was performed with a canine venous pouch aneurysm model. The closing forces (N) at 1 and 8 mm from the blade tip were 2.09 and 3.77 in YC, 1.85 and 3.04 in SC, and 2.05 and 4.60 in ZC. The maximum opening widths (mm) was 6.8, 9.0, and 3.0 in YC, SC, and ZC, respectively. The in vitro artifact volumes of YC, SC and ZC in time-of-flight MR imaging were 26.9, 29.7 and 1.9 times larger than the respective real volumes. The in vivo artifact volumes of YC, SC, and ZC were respectively 21.4, 29.4, and 2.6 times larger than real ones. ZC showed the smallest susceptibility artifacts and satisfactory closing forces. However, the narrow opening width of the blades was a weak point. Copyright © 2018. Published by Elsevier Inc.
Cormio, Luigi; Massenio, Paolo; Lucarelli, Giuseppe; Di Fino, Giuseppe; Selvaggio, Oscar; Micali, Salvatore; Carrieri, Giuseppe
2014-02-20
Hem-o-lok clips are widely used during robot-assisted and laparoscopic radical prostatectomy to control the lateral pedicles. There are a few reports of hem-o-lok clip migration into the bladder or vesico-urethral anastomosis and only four cases of hem-o-lok clip migration resulting into bladder neck contracture. Herein, we describe the first case, to our knowledge, of hem-o-lok clip migration leading to severe bladder neck contracture and subsequent stress urinary incontinence. A 62-year-old Caucasian man underwent robot-assisted laparoscopic radical prostatectomy for a T1c Gleason 8 prostate cancer. One month after surgery the patient was fully continent; however, three months later, he presented with acute urinary retention requiring suprapubic drainage. Urethroscopy showed a hem-o-lok clip strongly attached to the area between the vesico-urethral anastomosis and the urethral sphincter and a severe bladder neck contracture behind it. Following cold-knife urethral incision and clip removal, the bladder neck contracture was widely resected. At 3-month follow-up, the patient voided spontaneously with a peak flow rate of 9.5 ml/sec and absence of post-void residual urine, but leaked 240 ml urine at the 24-hour pad test. To date, at 1-year follow-up, his voiding situation remains unchanged. The present report provides further evidence for the risk of hem-o-lok clip migration causing bladder neck contracture, and is the first to demonstrate the potential of such complication to result into stress urinary incontinence.
Impulsivity moderates the effects of movie alcohol portrayals on adolescents' willingness to drink.
Gibbons, Frederick X; Kingsbury, John H; Wills, Thomas A; Finneran, Stephanie D; Dal Cin, Sonya; Gerrard, Meg
2016-05-01
This study examined impulsivity as a moderator of adolescents' reactions to positive versus negative portrayals of drinking in American movie clips. Impulsivity, along with willingness and intentions to drink in the future, were assessed in a pretest session. In the experimental sessions, adolescents viewed a series of clips that showed drinking associated with either positive outcomes (e.g., social facilitation) or negative outcomes (fights, arguments). A third group viewed clips with similar positive or negative outcomes, but no alcohol consumption. All participants then responded to an implicit measure of attentional bias regarding alcohol (a dot probe), followed by explicit alcohol measures (self-reports of willingness and intentions to drink). Hypotheses, based on dual-processing theories, were: (a) high-impulsive adolescents would respond more favorably than low-impulsive adolescents to the positive clips, but not the negative clips; and (b) this difference in reactions to the positive clips would be larger on the willingness than the intention measures. Results supported the hypotheses: Adolescents high in impulsivity reported the highest willingness to drink in the positive-clip condition, but were slightly less willing than others in the negative-clip condition. In addition, results on the dot probe task indicated that RTs to alcohol words were negatively correlated with changes in alcohol willingness, but not intention; that is, the faster their response to the alcohol words, the more their willingness increased. The results highlight the utility of a dual-processing perspective on media influence. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Fabrication and Characterization of ZnO Nano-Clips by the Polyol-Mediated Process
NASA Astrophysics Data System (ADS)
Wang, Mei; Li, Ai-Dong; Kong, Ji-Zhou; Gong, You-Pin; Zhao, Chao; Tang, Yue-Feng; Wu, Di
2018-02-01
ZnO nano-clips with better monodispersion were prepared successfully using zinc acetate hydrate (Zn(OAc)2·nH2O) as Zn source and ethylene glycol (EG) as solvent by a simple solution-based route-polyol process. The effect of solution concentration on the formation of ZnO nano-clips has been investigated deeply. We first prove that the 0.01 M Zn(OAc)2·nH2O can react with EG without added water or alkaline, producing ZnO nano-clips with polycrystalline wurtzite structure at 170 °C. As-synthesized ZnO nano-clips contain a lot of aggregated nanocrystals ( 5 to 15 nm) with high specific surface area of 88 m2/g. The shapes of ZnO nano-clips basically keep constant with improved crystallinity after annealing at 400-600 °C. The lower solution concentration and slight amount of H2O play a decisive role in ZnO nano-clip formation. When the solution concentration is ≤ 0.0125 M, the complexing and polymerization reactions between Zn(OAc)2·nH2O and EG predominate, mainly elaborating ZnO nano-clips. When the solution concentration is ≥ 0.015 M, the alcoholysis and polycondensation reactions of Zn(OAc)2·nH2O and EG become dominant, leading to ZnO particle formation with spherical and elliptical shapes. The possible growth mechanism based on a competition between complexing and alcoholysis of Zn(OAc)2·nH2O and EG has been proposed.
Liu, H-W; Wang, L-L; Meng, Z; Tang, X; Li, Y-S; Xia, Q-Y; Zhao, P
2017-10-01
Clip domain serine proteases (CLIPs), characterized by one or more conserved clip domains, are essential components of extracellular signalling cascades in various biological processes, especially in innate immunity and the embryonic development of insects. Additionally, CLIPs may have additional non-immune functions in insect development. In the present study, the clip domain serine protease gene Bombyx mori serine protease 95 (BmSP95), which encodes a 527-residue protein, was cloned from the integument of B. mori. Bioinformatics analysis indicated that BmSP95 is a typical CLIP of the subfamily D and possesses a clip domain at the N terminus, a trypsin-like serine protease (tryp_spc) domain at the C terminus and a conserved proline-rich motif between these two domains. At the transcriptional level, BmSP95 is expressed in the integument during moulting and metamorphosis, and the expression pattern is consistent with the fluctuating 20-hydroxyecdysone (20E) titre in B. mori. At the translational level, BmSP95 protein is synthesized in the epidermal cells, secreted as a zymogen and activated in the moulting fluid. Immunofluorescence revealed that BmSP95 is distributed into the old endocuticle in the moulting stage. The expression of BmSP95 was upregulated by 20E. Moreover, expression of BmSP95 was downregulated by pathogen infection. RNA interference-mediated silencing of BmSP95 led to delayed moulting from pupa to moth. These results suggest that BmSP95 is involved in integument remodelling during moulting and metamorphosis. © 2017 The Royal Entomological Society.
Lithner, Delilah; Halling, Maja; Dave, Göran
2012-05-01
Electronic waste has become one of the fastest growing waste problems in the world. It contains both toxic metals and toxic organics. The aim of this study was to (1) investigate to what extent toxicants can leach from different electronic products, components, and materials into water and (2) identify which group of toxicants (metals or hydrophobic organics) that is causing toxicity. Components from five discarded electronic products (cell phone, computer, phone modem, keyboard, and computer mouse) were leached in deionised water for 3 days at 23°C in concentrations of 25 g/l for metal components, 50 g/l for mixed-material components, and 100 g/l for plastic components. The water phase was tested for acute toxicity to Daphnia magna. Eighteen of 68 leachates showed toxicity (with immobility of D. magna ≥ 50% after 48 h) and came from metal or mixed-material components. The 8 most toxic leachates, with 48 h EC(50)s ranging from 0.4 to 20 g/l, came from 2 circuit sheets (key board), integrated drive electronics (IDE) cable clips (computer), metal studs (computer), a circuit board (computer mouse), a cord (phone modem), mixed parts (cell phone), and a circuit board (key board). All 5 electronic products were represented among them. Toxicity identification evaluations (with C18 and CM resins filtrations and ethylenediaminetetraacetic acid addition) indicated that metals caused the toxicity in the majority of the most toxic leachates. Overall, this study has shown that electronic waste can leach toxic compounds also during short-term leaching with pure water.
Using Humorous Sitcom Clips in Teaching Federal Income Taxes
ERIC Educational Resources Information Center
Cecil, H. Wayne
2014-01-01
This article shares the motivation, process, and outcomes of using humorous scenes from television comedies to teach the real world of tax practice. The article advances the literature by reviewing the use of video clips in a previously unexplored discipline, discussing the process of identifying and selecting appropriate clips, and introducing…
The statistical relationship between total mercury (Hg) concentration in clips from the caudal fin and muscle tissue of largemouth bass (Micropterus salmoides) from 26 freshwater sites in Rhode Island, USA was developed and evaluated to determine the utility of fin clip analysis ...
Capturing Students' Attention: Movie Clips Set the Stage for Learning in Abnormal Psychology.
ERIC Educational Resources Information Center
Badura, Amy S.
2002-01-01
Presents results of a study that evaluated using popular movie clips, shown in the first class meeting of an abnormal psychology course, in relation to student enthusiasm. Compares two classes of female juniors, one using clips and one class not using them. States that the films portrayed psychological disorders. (CMK)
First CLIPS Conference Proceedings, volume 2
NASA Technical Reports Server (NTRS)
1990-01-01
The topics of volume 2 of First CLIPS Conference are associated with following applications: quality control; intelligent data bases and networks; Space Station Freedom; Space Shuttle and satellite; user interface; artificial neural systems and fuzzy logic; parallel and distributed processing; enchancements to CLIPS; aerospace; simulation and defense; advisory systems and tutors; and intelligent control.
Moore, Michael; Zhang, Chaolin; Gantman, Emily Conn; Mele, Aldo; Darnell, Jennifer C.; Darnell, Robert B.
2014-01-01
Summary Identifying sites where RNA binding proteins (RNABPs) interact with target RNAs opens the door to understanding the vast complexity of RNA regulation. UV-crosslinking and immunoprecipitation (CLIP) is a transformative technology in which RNAs purified from in vivo cross-linked RNA-protein complexes are sequenced to reveal footprints of RNABP:RNA contacts. CLIP combined with high throughput sequencing (HITS-CLIP) is a generalizable strategy to produce transcriptome-wide RNA binding maps with higher accuracy and resolution than standard RNA immunoprecipitation (RIP) profiling or purely computational approaches. Applying CLIP to Argonaute proteins has expanded the utility of this approach to mapping binding sites for microRNAs and other small regulatory RNAs. Finally, recent advances in data analysis take advantage of crosslinked-induced mutation sites (CIMS) to refine RNA-binding maps to single-nucleotide resolution. Once IP conditions are established, HITS-CLIP takes approximately eight days to prepare RNA for sequencing. Established pipelines for data analysis, including for CIMS, take 3-4 days. PMID:24407355
Schmidt, Arthur; Riecken, Bettina; Damm, Michael; Cahyadi, Oscar; Bauder, Markus; Caca, Karel
2014-09-01
Over-the-scope clips (OTSCs; Ovesco Endoscopy, Tübingen, Germany) are extensively used for treatment of gastrointestinal perforations, leakages, fistulas, and bleeding. In this report, a new method of removing OTSCs using a prototype bipolar cutting device is described. A total of 11 patients underwent endoscopic removal of an OTSC. The OTSC was cut at two opposing sites by a prototype device (DC ClipCutter; Ovesco Endoscopy). The remaining clip fragments were extracted using a standard forceps. Mean procedure time was 47 minutes (range 35 - 75 minutes). Cutting of the OTSC at two opposing sites was successful in all cases (100 %). Complete retrieval of all clip fragments was possible in 10 patients (91 %). The overall success rate for cutting and complete removal of the clip was 91 %. No major complications were observed. Removal of OTSCs with the prototype device was feasible and effective. The device may be valuable for OTSC removal in emergency as well as elective indications. © Georg Thieme Verlag KG Stuttgart · New York.
Kinematic reconstruction of the Caribbean region since the Early Jurassic
NASA Astrophysics Data System (ADS)
Bochman, Lydian; van Hinsbergen, Douwe; Torsvik, Trond; Spakman, Wim; Pindell, James
2014-05-01
The Caribbean region results from a complex tectonic history governed by the interplay of the North American, South American and (Paleo-)Pacific plates, between which the Caribbean plate evolved since the early Cretaceous. During its entire tectonic evolution, the Caribbean plate was largely surrounded by subduction and transform boundaries, which hampers a quantitative integration into the global circuit of plate motions. In addition, reconstructions of the region have so far not resulted in a first order kinematic description of the main tectonic units in terms of Euler poles and finite rotation angles. Here, we present an updated, quantitatively described kinematic reconstruction of the Caribbean region back to 200 Ma integrated into the global plate circuit, and implemented with GPlates free software. Our analysis of Caribbean tectonic evolution incorporates an extensive literature review. To constrain the Caribbean plate motion between the American continents, we use a novel approach that takes structural geological observations rather than marine magnetic anomalies as prime input, and uses regionally extensive metamorphic and magmatic phenomena such as the Great Arc of the Caribbean, the Caribbean Large Igneous Province (CLIP) and the Caribbean high-pressure belt as correlation markers. The resulting model restores the Caribbean plate back along the Cayman Trough and major strike-slip faults in Guatemala, offshore Nicaragua, offshore Belize and along the Northern Andes towards its position of origin, west of the North and South American continents in early Cretaceous time. We provide the paleomagnetic reference frame for the Caribbean region by rotating the Global Apparent Polar Wander Path into coordinates of the Caribbean plate interior, Cuba, and the Chortis Block. We conclude that a plate kinematic scenario for a Panthalassa/Pacific origin of Caribbean lithosphere leads to a much simpler explanation than a Proto-Caribbean/Atlantic origin. Placing our reconstruction in the most recent mantle reference frames shows that the CLIP erupted 2000-3000 km east of the modern Galápagos hotspot, and may not have been derived from the corresponding mantle plume. Finally, our reconstruction suggests that most if not all modern subduction zones surrounding the Caribbean plate initiated at transform faults, two of these (along the southern Mexican and NW South American margins) evolved diachronously as a result of migrating trench-trench-transform triple junctions.
Analysis of left atrial respiratory and cardiac motion for cardiac ablation therapy
NASA Astrophysics Data System (ADS)
Rettmann, M. E.; Holmes, D. R.; Johnson, S. B.; Lehmann, H. I.; Robb, R. A.; Packer, D. L.
2015-03-01
Cardiac ablation therapy is often guided by models built from preoperative computed tomography (CT) or magnetic resonance imaging (MRI) scans. One of the challenges in guiding a procedure from a preoperative model is properly synching the preoperative models with cardiac and respiratory motion through computational motion models. In this paper, we describe a methodology for evaluating cardiac and respiratory motion in the left atrium and pulmonary veins of a beating canine heart. Cardiac catheters were used to place metal clips within and near the pulmonary veins and left atrial appendage under fluoroscopic and ultrasound guidance and a contrast-enhanced, 64-slice multidetector CT scan was collected with the clips in place. Each clip was segmented from the CT scan at each of the five phases of the cardiac cycle at both end-inspiration and end-expiration. The centroid of each segmented clip was computed and used to evaluate both cardiac and respiratory motion of the left atrium. A total of three canine studies were completed, with 4 clips analyzed in the first study, 5 clips in the second study, and 2 clips in the third study. Mean respiratory displacement was 0.2+/-1.8 mm in the medial/lateral direction, 4.7+/-4.4 mm in the anterior/posterior direction (moving anterior on inspiration), and 9.0+/-5.0 mm superior/inferior (moving inferior with inspiration). At end inspiration, the mean left atrial cardiac motion at the clip locations was 1.5+/-1.3 mm in the medial/lateral direction, and 2.1+/-2.0 mm in the anterior/posterior and 1.3+/-1.2 mm superior/inferior directions. At end expiration, the mean left atrial cardiac motion at the clip locations was 2.0+/-1.5mm in the medial/lateral direction, 3.0+/-1.8mm in the anterior/posterior direction, and 1.5+/-1.5 mm in the superior/inferior directions.
Public Awareness of Melioidosis in Thailand and Potential Use of Video Clips as Educational Tools
Chansrichavala, Praveen; Wongsuwan, Nittayasee; Suddee, Suthee; Malasit, Mayura; Hongsuwan, Maliwan; Wannapinij, Prapass; Kitphati, Rungreung; Day, Nicholas P. J.; Michie, Susan; Peacock, Sharon J.; Limmathurotsakul, Direk
2015-01-01
Background Melioidosis causes more than 1,000 deaths in Thailand each year. Infection occurs via inoculation, ingestion or inhalation of the causative organism (Burkholderia pseuodmallei) present in soil and water. Here, we evaluated public awareness of melioidosis using a combination of population-based questionnaire, a public engagement campaign to obtain video clips made by the public, and viewpoints on these video clips as potential educational tools about the disease and its prevention. Methods A questionnaire was developed to evaluate public awareness of melioidosis, and knowledge about its prevention. From 1 March to 31 April 2012, the questionnaire was delivered to five randomly selected adults in each of 928 districts in Thailand. A video clip contest entitled “Melioidosis, an infectious disease that Thais must know” was run between May and October 2012. The best 12 video clips judged by a contest committee were shown to 71 people at risk from melioidosis (diabetics). Focus group interviews were used to evaluate their perceptions of the video clips. Results Of 4,203 Thais who completed our study questionnaire, 74% had never heard of melioidosis, and 19% had heard of the disease but had no further knowledge. Most participants in all focus group sessions felt that video clips were beneficial and could positively influence them to increase adherence to recommended preventive behaviours, including drinking boiled water and wearing protective gear if in contact with soil or environmental water. Participants suggested that video clips should be presented in the local dialect with simple words rather than medical terms, in a serious manner, with a doctor as the one presenting the facts, and having detailed pictures of each recommended prevention method. Conclusions In summary, public awareness of melioidosis in Thailand is very low, and video clips could serve as a useful medium to educate people and promote disease prevention. Presented in Part World Melioidosis Congress 2013, Bangkok, Thailand, 18–20 September 2013 (abstract OS VII-04). PMID:25803048
Zhang, Xiaoxi; Li, Li; Hong, Bo; Xu, Yi; Liu, Yuan; Huang, Qinghai; Liu, Jianmin
2018-05-01
Healthcare expenditures and cost reduction have been under critical surveillance in all countries and are critical for policymakers. This review aims at qualitatively and quantitatively analyzing the difference of hospital costs and length of stay between endovascular coiling versus neurosurgical clipping in ruptured intracranial aneurysms (RAs). MEDLINE, the Cochrane database, Embase, and the Web of Science database were searched and evaluated independently by 2 authors according to the Newcastle-Ottawa Scale for cohort studies describing economic hospital cost or length of stay in patients with RAs. A total of 8 studies were included, describing 24,219 RAs treated with neurosurgical clipping and 24,962 RAs with endovascular coiling. Meta-analysis revealed that the total hospital costs (THCs) were similar between coiling versus clipping in RAs (standard mean difference [SMD], -0.05; 95% confidence interval [CI], -0.12 to 0.22; I 2 = 99%; P = 0.50). Subgroup analysis showed that THCs of clipping and coiling were similar in ruptured aneurysms in the United States. However, in South Korea, the THCs of coiling were significantly higher than clipping. In the long run, 1-year medical costs of endovascular treatment were significantly lower than that of clipping in RAs (SMD, 0.15; 95% CI, 0.05-0.25; I 2 = 66%; P = 0.005). In addition, the length of stay of coiled patients was significantly shorter than clipped patients (SMD, 0.29; 95% CI, 0.13-0.45; I 2 = 96%; P < 0.001). Medical costs were region-specified. In the United States, total hospital costs and 1-year medical costs were similar in RA patients treated with endovascular coiling and neurosurgical clipping. However, in countries like South Korea and China, coiling was more expensive. The length of stay was much shorter in coiled patients in all countries. Copyright © 2018. Published by Elsevier Inc.
Preoperative simulation for the planning of microsurgical clipping of intracranial aneurysms.
Marinho, Paulo; Vermandel, Maximilien; Bourgeois, Philippe; Lejeune, Jean-Paul; Mordon, Serge; Thines, Laurent
2014-12-01
The safety and success of intracranial aneurysm (IA) surgery could be improved through the dedicated application of simulation covering the procedure from the 3-dimensional (3D) description of the surgical scene to the visual representation of the clip application. We aimed in this study to validate the technical feasibility and clinical relevance of such a protocol. All patients preoperatively underwent 3D magnetic resonance imaging and 3D computed tomography angiography to build 3D reconstructions of the brain, cerebral arteries, and surrounding cranial bone. These 3D models were segmented and merged using Osirix, a DICOM image processing application. This provided the surgical scene that was subsequently imported into Blender, a modeling platform for 3D animation. Digitized clips and appliers could then be manipulated in the virtual operative environment, allowing the visual simulation of clipping. This simulation protocol was assessed in a series of 10 IAs by 2 neurosurgeons. The protocol was feasible in all patients. The visual similarity between the surgical scene and the operative view was excellent in 100% of the cases, and the identification of the vascular structures was accurate in 90% of the cases. The neurosurgeons found the simulation helpful for planning the surgical approach (ie, the bone flap, cisternal opening, and arterial tree exposure) in 100% of the cases. The correct number of final clip(s) needed was predicted from the simulation in 90% of the cases. The preoperatively expected characteristics of the optimal clip(s) (ie, their number, shape, size, and orientation) were validated during surgery in 80% of the cases. This study confirmed that visual simulation of IA clipping based on the processing of high-resolution 3D imaging can be effective. This is a new and important step toward the development of a more sophisticated integrated simulation platform dedicated to cerebrovascular surgery.
Maintainable substrate carrier for electroplating
Chen, Chen-An [Milpitas, CA; Abas, Emmanuel Chua [Laguna, PH; Divino, Edmundo Anida [Cavite, PH; Ermita, Jake Randal G [Laguna, PH; Capulong, Jose Francisco S [Laguna, PH; Castillo, Arnold Villamor [Batangas, PH; Ma,; Xiaobing, Diana [Saratoga, CA
2012-07-17
One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The carrier includes a non-conductive carrier body on which the substrates are placed and conductive lines embedded within the carrier body. A plurality of conductive clip attachment parts are attached in a permanent manner to the conductive lines embedded within the carrier body. A plurality of contact clips are attached in a removable manner to the clip attachment parts. The contact clips hold the substrates in place and conductively connecting the substrates with the conductive lines. Other embodiments, aspects and features are also disclosed.
Maintainable substrate carrier for electroplating
Chen, Chen-An; Abas, Emmanuel Chua; Divino, Edmundo Anida; Ermita, Jake Randal G.; Capulong, Jose Francisco S.; Castillo, Arnold Villamor; Ma, Diana Xiaobing
2016-08-02
One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The carrier includes a non-conductive carrier body on which the substrates are placed and conductive lines embedded within the carrier body. A plurality of conductive clip attachment parts are attached in a permanent manner to the conductive lines embedded within the carrier body. A plurality of contact clips are attached in a removable manner to the clip attachment parts. The contact clips hold the substrates in place and conductively connecting the substrates with the conductive lines. Other embodiments, aspects and features are also disclosed.
Greenberg, Tsafrir; Carlson, Joshua M; Rubin, Denis; Cha, Jiook; Mujica-Parodi, Lilianne
2015-04-01
The neural correlates of anxious anticipation have been primarily studied with aversive and neutral stimuli. In this study, we examined the effect of valence on anticipation by using high arousal aversive and positive stimuli and a condition of uncertainty (i.e. either positive or aversive). The task consisted of predetermined cues warning participants of upcoming aversive, positive, 'uncertain' (either aversive or positive) and neutral movie clips. Anticipation of all affective clips engaged common regions including the anterior insula, dorsal anterior cingulate cortex, thalamus, caudate, inferior parietal and prefrontal cortex that are associated with emotional experience, sustained attention and appraisal. In contrast, the nucleus accumbens and medial prefrontal cortex, regions implicated in reward processing, were selectively engaged during anticipation of positive clips (depicting sexually explicit content) and the mid-insula, which has been linked to processing aversive stimuli, was selectively engaged during anticipation of aversive clips (depicting graphic medical procedures); these three areas were also activated during anticipation of 'uncertain' clips reflecting a broad preparatory response for both aversive and positive stimuli. These results suggest that a common circuitry is recruited in anticipation of affective clips regardless of valence, with additional areas preferentially engaged depending on whether expected stimuli are negative or positive. © The Author (2014). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Nossek, Erez; Setton, Avi; Dehdashti, Amir R; Chalif, David J
2014-10-01
Proximally located posterior communicating artery (PCoA) aneurysms, projecting postero-laterally in proximity to the tentorium, may pose a technical challenge for microsurgical clipping due to obscuration of the proximal aneurysmal neck by the anterior petroclinoid fold. We describe an efficacious technique utilizing fenestration of the anterior petroclinoid fold to facilitate visualization and clipping of PCoA aneurysms abutting this aspect of the tentorium. Of 86 cases of PCoA aneurysms treated between 2003 and 2013, the technique was used in nine (10.5 %) patients to allow for adequate clipping. A 3 mm fenestration in the anterior petroclinoid ligament is created adjacent and lateral to the anterior clinoid process. This fenestration is then widened into a small wedge corridor by bipolar coagulation. In all cases, the proximal aneurysm neck was visualized after the wedge fenestration. Additionally, an adequate corridor for placement of the proximal clip blade was uniformly established. All cases were adequately clipped, with complete occlusion of the aneurysm neck and fundus with preservation of the PCoA. There were two intraoperative ruptures not related to creation of the wedge fenestration. One patient experienced post-operative partial third nerve palsy, which resolved during follow-up. We describe a technique of fenestration of the anterior petroclinoid fold to establish a critical and safe corridor for both visualization and clipping of PCoA aneurysms.
Schweier, Rebecca; Grande, Gesine; Richter, Cynthia; Riedel-Heller, Steffi G; Romppel, Matthias
2018-07-01
To investigate the use of lebensstil-aendern.de ("lifestyle change"), a website providing peer narratives of experiences with successful lifestyle change, and to analyze whether peer model characteristics, clip content, and media type have an influence on the number of visitors, dwell time, and exit rates. An in-depth statistical analysis of website use with multilevel regression analyses. In two years, lebensstil-aendern.de attracted 12,844 visitors. The in-depth statistical analysis of usage rates demonstrated that audio clips were less popular than video or text-only clips, longer clips attracted more visitors, and clips by younger and female interviewees were preferred. User preferences for clip content categories differed between heart and back pain patients. Clips about stress management drew the smallest numbers of visitors in both indication modules. Patients are interested in the experiences of others. Because the quality of information for user-generated content is generally low, healthcare providers should include quality-assured patient narratives in their interventions. User preferences for content, medium, and peer characteristics need to be taken into account. If healthcare providers decide to include patient experiences in their websites, they should plan their intervention according to the different needs and preferences of users. Copyright © 2018 Elsevier B.V. All rights reserved.
Borowicz, V A; Fitter, A H
1990-03-01
We examined how combinations of parentage, fungicide application, and artificial herbivory influence growth and shoot phosphorus content in pre-reproductive Lotus corniculatus, using young offspring arising from three parental crosses, two of which had one parent in common. Soil with vesicular-arbuscular mycorrhizal (VAM) fungi was treated with either water or benomyl, an anti-VAM fungicide, and added to trays containing groups of four full siblings. There were two experiments; in the first no plants were clipped while in the second two of the four plants were clipped to simulate herbivory. In both experiments plants of the two related crosses accumulated more biomass and total shoot P than did plants of the third cross. Plants inoculated with watertreated soil had greater shoot mass and P concentration than did fungicide-treated replicates but the extent of increase in P concentration varied among crosses. In Experiment 2, clipping reduced root mass and resulted in higher shoot P concentration. In this experiment there was a significant interaction of fungicide application and clipping: both unclipped and clipped plants grew better in soil not treated with fungicide, but the increase in shoot mass, total mass, and total P was greater in unclipped plants. Significant interaction of fungicide treatment and clipping is most likely due to reduced availability of carbon to the roots of clipped plants, resulting in poorer symbiotic functioning.
Huang, Huagang; Li, Tingqiang; Gupta, D K; He, Zhenli; Yang, Xiao-E; Ni, Bingnan; Li, Mao
2012-01-01
Improving the efficacy of phytoextraction is critical for its successful application in metal contaminated soils. Mineral nutrition affects plant growth and metal absorption and subsequently the accumulation of heavy metal through hyper-accumulator plants. This study assessed the effects of di-hydrogen phosphates (KH2PO4, Ca(H2PO4)2, NaH2PO4 and NH4H2PO4) application at three levels (22, 88 and 352 mg P/kg soil) on Sedum alfredii growth and metal uptake by three consecutive harvests on aged and Zn/Cd combined contaminated paddy soil. The addition of phosphates (P) significantly increased the amount of Zn taken up by S. alfredii due to increased shoot Zn concentration and dry matter yield (DMY) (P < 0.05). The highest phytoextraction of Zn and Cd was observed in KH2PO4 and NH4H2PO4 treatment at 352 mg P/kg soil. The amount of Zn removed by phytoextraction increased in the order of 1st clipping < 2nd clipping < 3rd clipping, and for Cd extraction the order was 2nd clipping < 1st clipping < 3rd clipping. These results indicate that the application of P fertilizers coupled with multiple cuttings can enhance the removal of Zn and Cd from contaminated soils by S. alfredii, thus shortening the time needed for accomplishing remediation goals.
Tracking Solar Energy Conersion Unit Adapted For Field Assembly
Kaminar, Neil R.; Ross, III, James G.; Carrie, Peter J.
2000-02-01
A modular solar energy collector having elongated V-shaped side walls formed by a pair of coplanar panels for each side wall. The upper panels, occupying most of the wall area are diffusely reflective, but the lower panels are specularly reflective. A Fresnel lens, having a snap fit relation to the side walls focuses some light on the lower specularly reflective panels which direct light to the solar cells at the base of the V-shaped walls. A heat sink provides support for the two panels with two opposed, upwardly extending wings terminating in opposed linear clips located near the lengthwise seam of the coplanar panels, each clip holding two coplanar panels in parallel alignment. The clips not only provide support for the panels, but also transfer heat to the remainder of the heat sink. The clips are shaped so that edges of the panels engage each clip by a snap fit, outside of the clip in one embodiment and inside of the clip in another embodiment. End caps are also formed with structures which snap to the wall panels. Since all junctions of components snap together, the collector of the present invention is easily assembled without specialized tools. Using side walls which are only partly specularly reflective permits a large angle of acceptance, yet provides an economical wall design because the entire wall need not be specularly reflective.
Clipping affects flowering of California poppy at two growth stages
Raymond D. Ratliff; Richard L. Hubbard
1975-01-01
The effects of clipping California-poppy (Eschscholzia californica Cham.) at various growth stages on plant survival, flowering, herbage yield, and root production were studied at the San Joaquin Experimental Range, in central California. Plants were clipped once to a 2-cm stubble at one of six stages. Through the early reproductive stage, a single...
[Clip Sheets from BOCES. Opportunities. Health. Careers. = Oportunidades. Salud. Una Camera En...
ERIC Educational Resources Information Center
State Univ. of New York, Geneseo. Coll. at Geneseo. Migrant Center.
This collection of 83 clip sheets, or classroom handouts, was created to help U.S. migrants learn more about health, careers, and general "opportunities" including education programs. They are written in both English and Spanish and are presented in an easily understandable format. Health clip-sheet topics include the following: Abuse; AIDS;…
The "Isms" of Art. Introduction to the 2001-2002 Clip and Save Art Prints.
ERIC Educational Resources Information Center
Hubbard, Guy
2001-01-01
Provides an introduction to the 2001-2002 Clip and Save Art Prints that will focus on ten art movements from the past 150 years. Includes information on three art movements, or "isms": Classicism, Romanticism, and Realism. Discusses the Clip and Save Art Print format and provides information on three artists. (CMK)
Gaberel, Thomas; Borha, Alin; di Palma, Camille; Emery, Evelyne
2016-03-01
To compare surgical clipping with endovascular coiling in terms of recovery from oculomotor nerve palsy (ONP) in the management of posterior communicating artery (PCoA) aneurysms causing third nerve palsy. We conducted a systematic review of the literature and meta-analysis. The meta-analysis included 11 relevant studies involving 384 patients with third nerve palsy caused by PCoA aneurysms at baseline, of whom 257 (67.0%) were treated by clipping and 127 were treated by coiling (33.0%). Pooled odds ratios of the impact of clipping or coiling on complete ONP recovery, lack of ONP recovery, and procedure-related death were calculated. The overall complete ONP recovery rate was 42.5% in the coiling group compared with 83.6% in the clipping group. The increase in complete ONP recovery in the clipping group corresponds to an overall pooled Mantel-Haenszel odds ratio of 4.44 (95% confidence interval = 1.66-11.84). Subgroup analysis revealed a clear benefit of clipping over coiling in patients with ruptured aneurysms, but not in patients with unruptured aneurysms. No procedure-related deaths were reported by any of the 11 studies. Surgical clipping of PCoA aneurysms causing third nerve palsy achieves better ONP recovery than endovascular coiling; this could be particularly true in the case of ruptured aneurysms. In view of the purely observational data, statements about this effect should be made with great caution. A randomized trial would better address the therapeutic dilemma, but pending the results of such a trial, we recommend treating PCoA aneurysms causing ONP with surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
Güresir, Erdem; Schuss, Patrick; Seifert, Volker; Vatter, Hartmut
2012-11-01
Resolution of oculomotor nerve palsy (ONP) after clipping of posterior communicating artery (PCoA) aneurysms has been well documented. However, whether additional decompression of the oculomotor nerve via aneurysm sac dissection or resection is superior to pure aneurysm clipping is the subject of much debate. Therefore, the objective in the present investigation was to analyze the influence of surgical strategy--specifically, clipping with or without aneurysm dissection--on ONP resolution. Between June 1999 and December 2010, 18 consecutive patients with ruptured and unruptured PCoA aneurysms causing ONP were treated at the authors' institution. Oculomotor nerve palsy was evaluated on admission and at follow-up. The electronic database MEDLINE was searched for additional data in published studies of PCoA aneurysms causing ONP. Two reviewers independently extracted data. Overall, 8 studies from the literature review and 6 patients in the current series (121 PCoA aneurysms) met the study inclusion criteria. Ninety-four aneurysms were treated with simple aneurysm neck clipping and 27 with clipping plus aneurysm sac decompression. The surgical strategy, simple aneurysm neck clipping versus clipping plus oculomotor nerve decompression, had no effect on full ONP resolution on univariate (p = 0.5) and multivariate analyses. On multivariate analysis, patients with incomplete ONP at admission were more likely to have full resolution of the palsy than were those with complete ONP at admission (p = 0.03, OR = 4.2, 95% CI 1.1-16). Data in the present study indicated that ONP caused by PCoA aneurysms improves after clipping without and with oculomotor nerve decompression. The resolution of ONP is inversely associated with the initial severity of ONP.
Early retreatment after surgical clipping of ruptured intracranial aneurysms.
Ito, Yoshiro; Yamamoto, Tetsuya; Ikeda, Go; Tsuruta, Wataro; Uemura, Kazuya; Komatsu, Yoji; Matsumura, Akira
2017-09-01
Although a rerupture after surgical clipping of ruptured intracranial aneurysms is rare, it is associated with high morbidity and mortality. The causes for retreatment and rupture after surgical clipping are not clearly defined. From a prospectively maintained database of 244 patients who had undergone surgical clipping of ruptured intracranial aneurysms, we selected patients who experienced retreatment or rerupture within 30 days after surgical clipping. Aneurysm occlusions were examined by microvascular Doppler ultrasonography and indocyanine green video-angiography. Indications for retreatment included rerupture and partial occlusion. We analyzed the characteristics and causes of early retreatment. Six patients (2.5%, 95% CI 0.9 to 5.3%) were retreated within 30 days after surgical clipping, including two patients (0.8%, 95% CI 0.1 to 2.9%) who experienced a rerupture. The retreated aneurysms were found in the anterior communicating artery (AcomA) (n = 5) and basilar artery (n = 1). Retreatment of the AcomA (7.5%) was performed significantly more frequently than that of other arteries (0.56%) (p < 0.01). A laterally projected AcomA aneurysm (17.4%) was more frequently retreated than were other aneurysm types (2.3%). Cases of laterally projecting AcomA aneurysms tended to result from an incomplete clip placed using a pterional approach from the opposite side of the aneurysm projection. Despite developments, the rates of retreatment and rerupture after surgical clipping remain similar to those reported previously. Retreatment of the AcomA was significantly more frequent than was retreatment of other arteries. Patients underwent retreatment more frequently when they were originally treated for lateral type aneurysms using a pterional approach from the opposite side of the aneurysm projection. The treatment method and evaluation modalities should be considered carefully for AcomA aneurysms in particular.
Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr
2017-07-01
Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Dunet, Vincent; Bernasconi, Martine; Hajdu, Steven David; Meuli, Reto Antoine; Daniel, Roy Thomas; Zerlauth, Jean-Baptiste
2017-09-01
We aimed to assess the impact of metal artifact reduction software (MARs) on image quality of gemstone spectral imaging (GSI) dual-energy (DE) cerebral CT angiography (CTA) after intracranial aneurysm clipping. This retrospective study was approved by the institutional review board, which waived patient written consent. From January 2013 to September 2016, single source DE cerebral CTA were performed in 45 patients (mean age: 60 ± 9 years, male 9) after intracranial aneurysm clipping and reconstructed with and without MARs. Signal-to-noise (SNR), contrast-to-noise (CNR), and relative CNR (rCNR) ratios were calculated from attenuation values measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Volume of clip and artifacts and relative clip blurring reduction (rCBR) ratios were also measured at each energy level with/without MARs. Variables were compared between GSI and GSI-MARs using the paired Wilcoxon signed-rank test. MARs significantly reduced metal artifacts at all energy levels but 130 and 140 keV, regardless of clips' location and number. The optimal rCBR was obtained at 110 and 80 keV, respectively, on GSI and GSI-MARs images, with up to 96% rCNR increase on GSI-MARs images. The best compromise between metal artifact reduction and rCNR was obtained at 70-75 and 65-70 keV for GSI and GSI-MARs images, respectively, with up to 15% rCBR and rCNR increase on GSI-MARs images. MARs significantly reduces metal artifacts on DE cerebral CTA after intracranial aneurysm clipping regardless of clips' location and number. It may be used to reduce radiation dose while increasing CNR.
Fabrication and Characterization of ZnO Nano-Clips by the Polyol-Mediated Process.
Wang, Mei; Li, Ai-Dong; Kong, Ji-Zhou; Gong, You-Pin; Zhao, Chao; Tang, Yue-Feng; Wu, Di
2018-02-09
ZnO nano-clips with better monodispersion were prepared successfully using zinc acetate hydrate (Zn(OAc) 2 ·nH 2 O) as Zn source and ethylene glycol (EG) as solvent by a simple solution-based route-polyol process. The effect of solution concentration on the formation of ZnO nano-clips has been investigated deeply. We first prove that the 0.01 M Zn(OAc) 2 ·nH 2 O can react with EG without added water or alkaline, producing ZnO nano-clips with polycrystalline wurtzite structure at 170 °C. As-synthesized ZnO nano-clips contain a lot of aggregated nanocrystals (~ 5 to 15 nm) with high specific surface area of 88 m 2 /g. The shapes of ZnO nano-clips basically keep constant with improved crystallinity after annealing at 400-600 °C. The lower solution concentration and slight amount of H 2 O play a decisive role in ZnO nano-clip formation. When the solution concentration is ≤ 0.0125 M, the complexing and polymerization reactions between Zn(OAc) 2 ·nH 2 O and EG predominate, mainly elaborating ZnO nano-clips. When the solution concentration is ≥ 0.015 M, the alcoholysis and polycondensation reactions of Zn(OAc) 2 ·nH 2 O and EG become dominant, leading to ZnO particle formation with spherical and elliptical shapes. The possible growth mechanism based on a competition between complexing and alcoholysis of Zn(OAc) 2 ·nH 2 O and EG has been proposed.
HITS-CLIP yields genome-wide insights into brain alternative RNA processing
NASA Astrophysics Data System (ADS)
Licatalosi, Donny D.; Mele, Aldo; Fak, John J.; Ule, Jernej; Kayikci, Melis; Chi, Sung Wook; Clark, Tyson A.; Schweitzer, Anthony C.; Blume, John E.; Wang, Xuning; Darnell, Jennifer C.; Darnell, Robert B.
2008-11-01
Protein-RNA interactions have critical roles in all aspects of gene expression. However, applying biochemical methods to understand such interactions in living tissues has been challenging. Here we develop a genome-wide means of mapping protein-RNA binding sites in vivo, by high-throughput sequencing of RNA isolated by crosslinking immunoprecipitation (HITS-CLIP). HITS-CLIP analysis of the neuron-specific splicing factor Nova revealed extremely reproducible RNA-binding maps in multiple mouse brains. These maps provide genome-wide in vivo biochemical footprints confirming the previous prediction that the position of Nova binding determines the outcome of alternative splicing; moreover, they are sufficiently powerful to predict Nova action de novo. HITS-CLIP revealed a large number of Nova-RNA interactions in 3' untranslated regions, leading to the discovery that Nova regulates alternative polyadenylation in the brain. HITS-CLIP, therefore, provides a robust, unbiased means to identify functional protein-RNA interactions in vivo.
Eliciting positive, negative and mixed emotional states: A film library for affective scientists.
Samson, Andrea C; Kreibig, Sylvia D; Soderstrom, Blake; Wade, A Ayanna; Gross, James J
2016-08-01
We describe the creation of a film library designed for researchers interested in positive (amusing), negative (repulsive), mixed (amusing and repulsive) and neutral emotional states. Three hundred 20- to 33-second film clips videotaped by amateurs were selected from video-hosting websites and screened in laboratory studies by 75 female participants on self-reported amusement and repulsion (Experiments 1 and 2). On the basis of pre-defined cut-off values, 51 positive, 39 negative, 59 mixed and 50 neutral film clips were selected. These film clips were then presented to 411 male and female participants in a large online study to identify film clips that reliably induced the target emotions (Experiment 3). Depending on the goal of the study, researchers may choose positive, negative, mixed or neutral emotional film clips on the basis of Experiments 1 and 2 or Experiment 3 ratings.
Embedded CLIPS for SDI BM/C3 simulation and analysis
NASA Technical Reports Server (NTRS)
Gossage, Brett; Nanney, Van
1990-01-01
Nichols Research Corporation is developing the BM/C3 Requirements Analysis Tool (BRAT) for the U.S. Army Strategic Defense Command. BRAT uses embedded CLIPS/Ada to model the decision making processes used by the human commander of a defense system. Embedding CLlPS/Ada in BRAT allows the user to explore the role of the human in Command and Control (C2) and the use of expert systems for automated C2. BRAT models assert facts about the current state of the system, the simulated scenario, and threat information into CLIPS/Ada. A user-defined rule set describes the decision criteria for the commander. We have extended CLIPS/Ada with user-defined functions that allow the firing of a rule to invoke a system action such as weapons release or a change in strategy. The use of embedded CLIPS/Ada will provide a powerful modeling tool for our customer at minimal cost.
Using PVM to host CLIPS in distributed environments
NASA Technical Reports Server (NTRS)
Myers, Leonard; Pohl, Kym
1994-01-01
It is relatively easy to enhance CLIPS (C Language Integrated Production System) to support multiple expert systems running in a distributed environment with heterogeneous machines. The task is minimized by using the PVM (Parallel Virtual Machine) code from Oak Ridge Labs to provide the distributed utility. PVM is a library of C and FORTRAN subprograms that supports distributive computing on many different UNIX platforms. A PVM deamon is easily installed on each CPU that enters the virtual machine environment. Any user with rsh or rexec access to a machine can use the one PVM deamon to obtain a generous set of distributed facilities. The ready availability of both CLIPS and PVM makes the combination of software particularly attractive for budget conscious experimentation of heterogeneous distributive computing with multiple CLIPS executables. This paper presents a design that is sufficient to provide essential message passing functions in CLIPS and enable the full range of PVM facilities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedman-Hill, Ernest
Java Expert Shell System - Jess - is a rule engine and scripting environment written entirely in Sun's Java language, Jess was orginially inspired by the CLIPS expert system shell, but has grown int a complete, distinct JAVA-influenced environment of its own. Using Jess, you can build Java applets and applications that have the capacity to "reason" using knowledge you supply in the form of declarative rules. Jess is surprisingly fast, and for some problems is faster than CLIPS, in that many Jess scripts are valid CLIPS scripts and vice-versa. Like CLIPS, Jess uses the Rete algorithm to process rules,more » a very efficient mechanism for solving the difficult many-to-many matching problem. Jess adds many features to CLIPS, including backwards chaining and the ability to manipulate and directly reason about Java objects. Jess is also a powerful Java scripting environment, from which you can create Java objects and call Java methods without compiling any Java Code.« less
Integrating CLIPS applications into heterogeneous distributed systems
NASA Technical Reports Server (NTRS)
Adler, Richard M.
1991-01-01
SOCIAL is an advanced, object-oriented development tool for integrating intelligent and conventional applications across heterogeneous hardware and software platforms. SOCIAL defines a family of 'wrapper' objects called agents, which incorporate predefined capabilities for distributed communication and control. Developers embed applications within agents and establish interactions between distributed agents via non-intrusive message-based interfaces. This paper describes a predefined SOCIAL agent that is specialized for integrating C Language Integrated Production System (CLIPS)-based applications. The agent's high-level Application Programming Interface supports bidirectional flow of data, knowledge, and commands to other agents, enabling CLIPS applications to initiate interactions autonomously, and respond to requests and results from heterogeneous remote systems. The design and operation of CLIPS agents are illustrated with two distributed applications that integrate CLIPS-based expert systems with other intelligent systems for isolating and mapping problems in the Space Shuttle Launch Processing System at the NASA Kennedy Space Center.
What's Eating Gilbert Grape?: A Case Study of Chronic Illness
ERIC Educational Resources Information Center
Alexander, Matthew; Waxman, Dael; White, Patricia
2006-01-01
Cinemeducation refers to the use of movies or movie clips to educate learners about the psychosocial aspects of health care. This paper describes the use of a clip from the movie, "What's Eating Gilbert Grape?" to teach medical students about chronic illness. The clip is used to set up a case study based on the lead character, Gilbert…
First CLIPS Conference Proceedings, volume 1
NASA Technical Reports Server (NTRS)
1990-01-01
The first Conference of C Language Production Systems (CLIPS) hosted by the NASA-Lyndon B. Johnson Space Center in August 1990 is presented. Articles included engineering applications, intelligent tutors and training, intelligent software engineering, automated knowledge acquisition, network applications, verification and validation, enhancements to CLIPS, space shuttle quality control/diagnosis applications, space shuttle and real-time applications, and medical, biological, and agricultural applications.
Using Film Clips to Teach Teen Pregnancy Prevention: "The Gloucester 18" at a Teen Summit
ERIC Educational Resources Information Center
Herrman, Judith W.; Moore, Christopher C.; Anthony, Becky
2012-01-01
Teaching pregnancy prevention to large groups offers many challenges. This article describes the use of film clips, with guided discussion, to teach pregnancy prevention. In order to analyze the costs associated with teen pregnancy, a film clip discussion session based with the film "The Gloucester 18" was the keynote of a youth summit. The lesson…
C Language Integrated Production System, Ada Version
NASA Technical Reports Server (NTRS)
Culbert, Chris; Riley, Gary; Savely, Robert T.; Melebeck, Clovis J.; White, Wesley A.; Mcgregor, Terry L.; Ferguson, Melisa; Razavipour, Reza
1992-01-01
CLIPS/Ada provides capabilities of CLIPS v4.3 but uses Ada as source language for CLIPS executable code. Implements forward-chaining rule-based language. Program contains inference engine and language syntax providing framework for construction of expert-system program. Also includes features for debugging application program. Based on Rete algorithm which provides efficient method for performing repeated matching of patterns. Written in Ada.
NASA Technical Reports Server (NTRS)
1994-01-01
C Language Integrated Production System (CLIPS), a NASA-developed software shell for developing expert systems, has been embedded in a PC-based expert system for training oil rig personnel in monitoring oil drilling. Oil drilling rigs if not properly maintained for possible blowouts pose hazards to human life, property and the environment may be destroyed. CLIPS is designed to permit the delivery of artificial intelligence on computer. A collection of rules is set up and, as facts become known, these rules are applied. In the Well Site Advisor, CLIPS provides the capability to accurately process, predict and interpret well data in a real time mode. CLIPS was provided to INTEQ by COSMIC.
NASA Technical Reports Server (NTRS)
Krolak, Patrick D.
1990-01-01
CLIPS is an expert system, created specifically to allow rapid implementation of an expert system. CLIPS is written in C, and thus needs a very small amount of memory to run. Parallel CLIPS (PCLIPS) is an extension to CLIPS which is intended to be used in situations where a group of expert systems are expected to run simultaneously and occasionally communicate with each other on an integrated network. PCLIPS is a coarse-grained data distribution system. Its main goal is to take information in one knowledge base and distribute it to other knowledge bases so that all the executing expert systems are able to use that knowledge to solve their disparate problems.
Microleakage of different temporary filling materials in primary teeth.
Odabas, Mesut Enes; Tulunoglu, Ozlem; Ozalp, Serife Ozdemir; Bodur, Haluk
2009-01-01
The aim of this study was to compare the sealing properties of IRM, Coltosol, Cavit G, Adhesor and Clip, which used as temporary filling material in coronal access openings in extracted human primary teeth. Standardized access cavities of 2 x 2 mm were prepared in the eighty-four, caries-free human primary anterior teeth. The teeth were divided randomly into five groups of 16 teeth each. Temporary restorative materials Group A: IRM (Dentsply), Group B: Coltosol (Coltone), Group C: Cavit G (3M), Group D: Adhesor (Spofa Dental) and Group E: Clip (Voco) were applied according to the manufacturer's directions. The specimens were immersed silver nitrate and placed in film developer under fluorescent for 24 hours. The sectioned specimens were evaluated under a digital microscope at x 20 magnifications and blindly scored for microleakage. Clip presented the least microleakage value whereas; Adhesor and IRM presented the higher microleakage values. There were statistically significant differences between Clip and the others groups, while there were no statistically significant differences in microleakage between IRM, Adhesor, Coltosol and Cavit G. However the leakage scores of Clip and Cavit G were congruent (p = 0.454). Amongst the five materials, Clip exhibited a better sealing ability.
Rumen fluid fermentation for enhancement of hydrolysis and acidification of grass clipping.
Wang, Siqi; Zhang, Guangming; Zhang, Panyue; Ma, Xiaowen; Li, Fan; Zhang, Haibo; Tao, Xue; Ye, Junpei; Nabi, Mohammad
2018-08-15
Rumen fluid, formed in rumen of ruminants, includes a complex microbial population of bacteria, protozoa, fungi and archaea, and has high ability to degrade lignocellulosic biomass. In this study, rumen fluid was used to ferment grass clipping for enhancing the hydrolysis and acidification of organic matters. Results showed that strict anaerobic condition, higher grass clipping content and smaller particle size of grass clipping were beneficial to the hydrolysis and acidification of organics. The increase of SCOD and total VFA concentration respectively reached 24.9 and 10.2 g/L with a suitable grass clipping content of 5%, a particle size <0.150 mm, and a fermentation time of 48 h. The VFA production was mainly attributed to the degradation of cellulose and hemicellulose with a total solid reduction of 55.7%. Firmicutes and Fibrobacteres were the major contributors to the degradation of cellulose and hemicellulose. The activity of carboxymethyl cellulose enzyme (CMCase), cellobiase and xylanase reached 0.027, 0.176 and 0.180 U/ml, respectively. The rumen fluid microorganisms successfully enhanced the hydrolysis and acidification of grass clipping. Copyright © 2018 Elsevier Ltd. All rights reserved.
Responses to water depth and clipping of twenty−three plant species in an Indian monsoonal wetland
Middleton, Beth A.; van der Valk, Arnold; Davis, Craig B.
2015-01-01
Responses of species to disturbances give insights into how species might respond to future wetland changes. In this study, species of monsoonal wetlands belonging to various functional types (graminoid and non−graminoid emergents, submersed aquatic, floating−leaved aquatic) varied in their growth responses to water depth and harvesting. We tested the effects of water depth (moist soil, flooded) and clipping (unclipped, and clipped) on the biomass and longevity of twenty−three dominant plant species of monsoonal wetlands in the Keoladeo National Park, India in a controlled experiment. With respect to total biomass and survival, six species responded positively to flooding and twelve species responded negatively to clipping. Responses to flooding and clipping, however, sometimes interacted. Individualistic responses of species to water levels and clipping regimes were apparent; species within a functional group did not always respond similarly. Therefore, detailed information on the individualistic responses of species may be needed to predict the vegetation composition of post−disturbance wetlands. In particular, as demands for fresh water increase around the world, studies of life history constraints and responses to hydrological changes will aid wetland managers in developing strategies to conserve biodiversity.
Process development for high-resolution 3D-printing of bioresorbable vascular stents
NASA Astrophysics Data System (ADS)
Ware, Henry Oliver T.; Farsheed, Adam C.; van Lith, Robert; Baker, Evan; Ameer, Guillermo; Sun, Cheng
2017-02-01
The recent development of "continuous projection microstereolithography" also known as CLIP technology has successfully alleviated the main obstacles surrounding 3D printing technologies: production speed and part quality. Following the same working principle, we further developed the μCLIP process to address the needs for high-resolution 3D printing of biomedical devices with micron-scale precision. Compared to standard stereolithography (SLA) process, μCLIP fabrication can reduce fabrication time from several hours to as little as a few minutes. μCLIP can also produce better surface finish and more uniform mechanical properties than conventional SLA, as each individual "fabrication layer" continuously polymerizes into the subsequent layer. In this study, we report the process development in manufacturing high-resolution bioresorbable stents using our own μCLIP system. The bioresorbable photopolymerizable biomaterial (B-ink) used in this study is methacrylated poly(1, 12 dodecamethylene citrate) (mPDC). Through optimization of our μCLIP process and concentration of B-ink components, we have created a customizable bioresorbable stent with similar mechanical properties exhibited by nitinol stents. Upon optimization, fabricating a 2 cm tall vascular stent that comprises 4000 layers was accomplished in 26.5 minutes.
Effects of orally administered lavender essential oil on responses to anxiety-provoking film clips.
Bradley, Belinda F; Brown, Stephen L; Chu, Simon; Lea, Robert W
2009-06-01
Lavender odour is commonly used to alleviate mild anxiety. Double blind studies are difficult to conduct with odours, and there are few reliable investigations of lavender's efficacy. Orally administered lavender capsules (placebo, 100, 200 microl) were tested in a randomised between-subjects (n = 97) double-blind study. Film clips were used to elicit anxiety. Measures included anxiety, State Trait Anxiety Inventory (STAI), mood, positive and negative affect scale (PANAS), heart rate (HR), galvanic skin response (GSR), and heart rate variation (HRV). Following baseline measurements capsules were administered. Participants viewed a neutral film clip, then an anxiety-provoking and light-hearted recovery film clip. For the 200 microl lavender dose during the neutral film clip there was a trend towards reduced state anxiety, GSR and HR and increased HRV. In the anxiety-eliciting film, lavender was mildly beneficial in females but only on HRV measures. In males sympathetic arousal increased during the anxiety film (GSR). HRV significantly increased at 200 microl during all three film clips in females, suggesting decreased anxiety. These findings suggest that lavender has anxiolytic effects in humans under conditions of low anxiety, but these effects may not extend to conditions of high anxiety.
Alleviating travel anxiety through virtual reality and narrated video technology.
Ahn, J C; Lee, O
2013-01-01
This study presents an empirical evidence of benefit of narrative video clips in embedded virtual reality websites of hotels for relieving travel anxiety. Even though it was proven that virtual reality functions do provide some relief in travel anxiety, a stronger virtual reality website can be built when narrative video clips that show video clips with narration about important aspects of the hotel. We posit that these important aspects are 1. Escape route and 2. Surrounding neighborhood information, which are derived from the existing research on anxiety disorder as well as travel anxiety. Thus we created a video clip that showed and narrated about the escape route from the hotel room, another video clip that showed and narrated about surrounding neighborhood. We then conducted experiments with this enhanced virtual reality website of a hotel by having human subjects play with the website and fill out a questionnaire. The result confirms our hypothesis that there is a statistically significant relationship between the degree of travel anxiety and psychological relief caused by the use of embedded virtual reality functions with narrative video clips of a hotel website (Tab. 2, Fig. 3, Ref. 26).
Teaching professionalism to first year medical students using video clips.
Shevell, Allison Haley; Thomas, Aliki; Fuks, Abraham
2015-01-01
Medical schools are confronted with the challenge of teaching professionalism during medical training. The aim of this study was to examine medical students' perceptions of using video clips as a beneficial teaching tool to learn professionalism and other aspects of physicianship. As part of the longitudinal Physician Apprenticeship course at McGill University, first year medical students viewed video clips from the television series ER. The study used qualitative description and thematic analysis to interpret responses to questionnaires, which explored the educational merits of this exercise. Completed questionnaires were submitted by 112 students from 21 small groups. A major theme concerned the students' perceptions of the utility of video clips as a teaching tool, and consisted of comments organized into 10 categories: "authenticity and believability", "thought provoking", "skills and approaches", "setting", "medium", "level of training", "mentorship", "experiential learning", "effectiveness" and "relevance to practice". Another major theme reflected the qualities of physicianship portrayed in video clips, and included seven categories: "patient-centeredness", "communication", "physician-patient relationship", "professionalism", "ethical behavior", "interprofessional practice" and "mentorship". This study demonstrated that students perceived the value of using video clips from a television series as a means of teaching professionalism and other aspects of physicianship.
Fukuda, Hitoshi; Hayashi, Kosuke; Yoshino, Kumiko; Koyama, Takashi; Lo, Benjamin; Kurosaki, Yoshitaka; Yamagata, Sen
2016-03-01
Surgical clipping of ruptured posterior communicating artery (PCoA) aneurysms is a well-established procedure to date. However, preoperative factors associated with procedure-related risk require further elucidation. To investigate the impact of the direction of aneurysm projection on the incidence of procedure-related complications during surgical clipping of ruptured PCoA aneurysms. A total of 65 patients with ruptured PCoA aneurysms who underwent surgical clipping were retrospectively analyzed from a single-center, prospective, observational cohort database in this study. The aneurysms were categorized into lateral and posterior projection groups, depending on direction of the dome. Characteristics and operative findings of each projection group were identified. We also evaluated any correlation of aneurysm projection with the incidence of procedure-related complications. Patients with ruptured PCoA aneurysms with posterior projection more likely presented with good-admission-grade subarachnoid hemorrhage (P = .01, χ test) and were less to also have intracerebral hematoma (P = .01). These aneurysms were found to be associated with higher incidence of intraoperative rupture (P = .02), complex clipping with fenestrated clips (P = .02), and dense adherence to PCoA or its perforators (P = .04) by univariate analysis. Aneurysms with posterior projection were also correlated with procedure-related complications, including postoperative cerebral infarction or hematoma formation (odds ratio, 5.87; 95% confidence interval, 1.11-31.1; P = .04) by multivariable analysis. Ruptured PCoA aneurysms with posterior projection carried a higher risk of procedure-related complications of surgical clipping than those with lateral projection.
Shono, Naoyuki; Kin, Taichi; Nomura, Seiji; Miyawaki, Satoru; Saito, Toki; Imai, Hideaki; Nakatomi, Hirofumi; Oyama, Hiroshi; Saito, Nobuhito
2018-05-01
A virtual reality simulator for aneurysmal clipping surgery is an attractive research target for neurosurgeons. Brain deformation is one of the most important functionalities necessary for an accurate clipping simulator and is vastly affected by the status of the supporting tissue, such as the arachnoid membrane. However, no virtual reality simulator implementing the supporting tissue of the brain has yet been developed. To develop a virtual reality clipping simulator possessing interactive brain deforming capability closely dependent on arachnoid dissection and apply it to clinical cases. Three-dimensional computer graphics models of cerebral tissue and surrounding structures were extracted from medical images. We developed a new method for modifiable cerebral tissue complex deformation by incorporating a nonmedical image-derived virtual arachnoid/trabecula in a process called multitissue integrated interactive deformation (MTIID). MTIID made it possible for cerebral tissue complexes to selectively deform at the site of dissection. Simulations for 8 cases of actual clipping surgery were performed before surgery and evaluated for their usefulness in surgical approach planning. Preoperatively, each operative field was precisely reproduced and visualized with the virtual brain retraction defined by users. The clear visualization of the optimal approach to treating the aneurysm via an appropriate arachnoid incision was possible with MTIID. A virtual clipping simulator mainly focusing on supporting tissues and less on physical properties seemed to be useful in the surgical simulation of cerebral aneurysm clipping. To our knowledge, this article is the first to report brain deformation based on supporting tissues.
The effect of music video clips on adolescent boys' body image, mood, and schema activation.
Mulgrew, Kate E; Volcevski-Kostas, Diana; Rendell, Peter G
2014-01-01
There is limited research that has examined experimentally the effects of muscular images on adolescent boys' body image, with no research specifically examining the effects of music television. The aim of the current study was to examine the effects of viewing muscular and attractive singers in music video clips on early, mid, and late adolescent boys' body image, mood, and schema activation. Participants were 180 boys in grade 7 (mean age = 12.73 years), grade 9 (mean age = 14.40 years) or grade 11 (mean age = 16.15 years) who completed pre- and post-test measures of mood and body satisfaction after viewing music videos containing male singers of muscular or average appearance. They also completed measures of schema activation and social comparison after viewing the clips. The results showed that the boys who viewed the muscular clips reported poorer upper body satisfaction, lower appearance satisfaction, lower happiness, and more depressive feelings compared to boys who viewed the clips depicting singers of average appearance. There was no evidence of increased appearance schema activation but the boys who viewed the muscular clips did report higher levels of social comparison to the singers. The results suggest that music video clips are a powerful form of media in conveying information about the male ideal body shape and that negative effects are found in boys as young as 12 years.
Gilman, T Lee; Shaheen, Razan; Nylocks, K Maria; Halachoff, Danielle; Chapman, Jessica; Flynn, Jessica J; Matt, Lindsey M; Coifman, Karin G
2017-12-01
Emotions are highly influential to many psychological processes. Indeed, research employing emotional stimuli is rapidly escalating across the field of psychology. However, challenges remain regarding discrete evocation of frequently co-elicited emotions such as amusement and happiness, or anger and disgust. Further, as much contemporary work in emotion employs college students, we sought to additionally evaluate the efficacy of film clips to discretely elicit these more challenging emotions in a young adult population using an online medium. The internet is an important tool for investigating responses to emotional stimuli, but validations of emotionally evocative film clips across laboratory and web-based settings are limited in the literature. An additional obstacle is identifying stimuli amidst the numerous film clip validation studies. During our investigation, we recognized the lack of a categorical database to facilitate rapid identification of useful film clips for individual researchers' unique investigations. Consequently, here we also sought to produce the first compilation of such stimuli into an accessible and comprehensive catalog. We based our catalog upon prior work as well as our own, and identified 24 articles and 295 film clips from four decades of research. We present information on the validation of these clips in addition to our own research validating six clips using online administration settings. The results of our search in the literature and our own study are presented in tables designed to facilitate and improve a selection of highly valid film stimuli for future research.
Hartmann, E; Bøe, K E; Jørgensen, G H M; Mejdell, C M; Dahlborn, K
2017-03-01
Limited information is available on the extent to which blankets are used on horses and the owners' reasoning behind clipping the horse's coat. Research on the effects of those practices on horse welfare is scarce but results indicate that blanketing and clipping may not be necessary from the horse's perspective and can interfere with the horse's thermoregulatory capacities. Therefore, this survey collected robust, quantitative data on the housing routines and management of horses with focus on blanketing and clipping practices as reported by members of the Swedish and Norwegian equestrian community. Horse owners were approached via an online survey, which was distributed to equestrian organizations and social media. Data from 4,122 Swedish and 2,075 Norwegian respondents were collected, of which 91 and 84% of respondents, respectively, reported using blankets on horses during turnout. Almost all respondents owning warmblood riding horses used blankets outdoors (97% in Sweden and 96% in Norway) whereas owners with Icelandic horses and coldblood riding horses used blankets significantly less ( < 0.05). Blankets were mainly used during rainy, cold, or windy weather conditions and in ambient temperatures of 10°C and below. The horse's coat was clipped by 67% of respondents in Sweden and 35% of Norwegian respondents whereby owners with warmblood horses and horses primarily used for dressage and competition reported clipping the coat most frequently. In contrast to scientific results indicating that recovery time after exercise increases with blankets and that clipped horses have a greater heat loss capacity, only around 50% of respondents agreed to these statements. This indicates that evidence-based information on all aspects of blanketing and clipping has not yet been widely distributed in practice. More research is encouraged, specifically looking at the effect of blankets on sweaty horses being turned out after intense physical exercise and the effect of blankets on social interactions such as mutual grooming. Future efforts should be tailored to disseminate knowledge more efficiently, which can ultimately stimulate thoughtful decision-making by horse owners concerning the use of blankets and clipping the horse's coat.
Four-year trends in the treatment of cerebral aneurysms in Poland in 2009-2012.
Tykocki, Tomasz; Kostyra, Kacper; Czyż, Marcin; Kostkiewicz, Bogusław
2014-05-01
The dilemma concerning the appropriate treatment of the intracranial aneurysms (IAs) has not yet been resolved and still remains under fierce debate. This study refers to the recent trends in the use of and outcomes related to coiling compared with clipping for unruptured and ruptured IAs in Poland over a 4-year period. The analysis refers to treatment of IAs performed in Poland between 2009-2012. Patients' records were cross-matched by ICD-9 codes for ruptured SAH (430) or unruptured cerebral aneurysm (437.3) along with codes for clipping (39.51) and coiling (39.79, 39.72, or 39.52). Multivariable logistic regression was used to compare in-hospital deaths, hospital length of stay (LOS), therapy allocation and aneurysm locations in unruptured vs. ruptured and clipped vs. coiled groups. Differences in the number of procedures between 16 administrative regions were standardized per 100,000 people. In 2009-2012, 11,051 procedures were identified, including 5,968 ruptured and 5,083 unruptured aneurysms. Overall increase was 2.3 % in clipping and 13.1 % in coiling; a significant trend was found in endovascular procedures (p = 0.044). Ruptured aneurysms were clipped more frequently (OR = 1.66;); in unruptured IAs, endovascular procedure was preferred 3.5 times more than clipping. The annual in-hospital mortality was 7.6 % in clipping and 6.7 % in endovascular treatment. LOS was two times longer after clipping in unruptured aneurysms (OR = 2.013). After the procedures were standardized per 100,000 people, the average for Poland was established as 9.09 in 2009, 10.86 in 2010, 10.55 in 2011, and 11.49 in 2012. This index had the highest values in Mazovia (12.9, 2009; 15.4, 2010; 17.4, 2011; 18.6, 2012. Data analysis revealed an increase in overall number of IAs treated in Poland between 2009-2012. A significant upward trend of endovascular procedures was found, whereas the number of clipped aneurysms remained relatively steady over the study period.
NASA Technical Reports Server (NTRS)
Gryphon, Coranth D.; Miller, Mark D.
1991-01-01
PCLIPS (Parallel CLIPS) is a set of extensions to the C Language Integrated Production System (CLIPS) expert system language. PCLIPS is intended to provide an environment for the development of more complex, extensive expert systems. Multiple CLIPS expert systems are now capable of running simultaneously on separate processors, or separate machines, thus dramatically increasing the scope of solvable tasks within the expert systems. As a tool for parallel processing, PCLIPS allows for an expert system to add to its fact-base information generated by other expert systems, thus allowing systems to assist each other in solving a complex problem. This allows individual expert systems to be more compact and efficient, and thus run faster or on smaller machines.
Ischemic mass effect from biliary surgical clips.
Mateo, Rod; Tsai, Steven; Stapfer, Maria V; Sher, Linda S; Selby, Rick; Genyk, Yuri S
2008-02-01
Migrating surgical clips in the hepatic hilum are known causes of biliary stricture or obstruction, most often due to direct intraluminal obstruction or secondary stone formation. Two cases are reported on patients with previous cholecystectomies presenting with delayed symptoms of biliary tract stricture. Both patients were successfully treated with a resection of the strictured area and a Roux-en-Y hepatico-jejunostomy. Resected specimens grossly demonstrated surgical clips adjacent to the stricture, but not directly within the lumen, suggestive of an ischemic mass effect, which was supported by histology. In addition to the direct intraluminal obstruction and lithogenic effects of migratory surgical clips, "clipomas" due to an ischemic mass effect can also lead to biliary tract strictures.
Sturm, Virginia E.; Yokoyama, Jennifer S.; Eckart, Janet A.; Zakrzewski, Jessica; Rosen, Howard J.; Miller, Bruce L.; Seeley, William W.; Levenson, Robert W.
2015-01-01
Positive emotions foster social relationships and motivate thought and action. Dysregulation of positive emotion may give rise to debilitating clinical symptomatology such as mania, risk-taking, and disinhibition. Neuroanatomically, there is extensive evidence that the left hemisphere of the brain, and the left frontal lobe in particular, plays an important role in positive emotion generation. Although prior studies have found that left frontal injury decreases positive emotion, it is not clear whether selective damage to left frontal emotion regulatory systems can actually increase positive emotion. We measured happiness reactivity in 96 patients with frontotemporal dementia, a neurodegenerative disease that targets emotion-relevant neural systems and causes alterations in positive emotion (i.e., euphoria and jocularity), and in 34 healthy controls. Participants watched a film clip designed to elicit happiness and a comparison film clip designed to elicit sadness while their facial behavior, physiological reactivity, and self-reported emotional experience were monitored. Whole-brain voxel-based morphometry analyses revealed that atrophy in predominantly left hemisphere fronto-striatal emotion regulation systems including left ventrolateral prefrontal cortex, orbitofrontal cortex, anterior insula, and striatum (pFWE < .05) was associated with greater happiness facial behavior during the film. Atrophy in left anterior insula and bilateral frontopolar cortex was also associated with higher cardiovascular reactivity (i.e., heart rate and blood pressure) but not self-reported positive emotional experience during the happy film (p< .005, uncorrected). No regions emerged as being associated with greater sadness reactivity, which suggests that left-lateralized fronto-striatal atrophy is selectively associated with happiness dysregulation. Whereas previous models have proposed that left frontal injury decreases positive emotional responding, we argue that selective disruption of left hemisphere emotion regulating systems can impair the ability to suppress positive emotions such as happiness. PMID:25461707
Portable inference engine: An extended CLIPS for real-time production systems
NASA Technical Reports Server (NTRS)
Le, Thach; Homeier, Peter
1988-01-01
The present C-Language Integrated Production System (CLIPS) architecture has not been optimized to deal with the constraints of real-time production systems. Matching in CLIPS is based on the Rete Net algorithm, whose assumption of working memory stability might fail to be satisfied in a system subject to real-time dataflow. Further, the CLIPS forward-chaining control mechanism with a predefined conflict resultion strategy may not effectively focus the system's attention on situation-dependent current priorties, or appropriately address different kinds of knowledge which might appear in a given application. Portable Inference Engine (PIE) is a production system architecture based on CLIPS which attempts to create a more general tool while addressing the problems of real-time expert systems. Features of the PIE design include a modular knowledge base, a modified Rete Net algorithm, a bi-directional control strategy, and multiple user-defined conflict resolution strategies. Problems associated with real-time applications are analyzed and an explanation is given for how the PIE architecture addresses these problems.
CLIP-related methodologies and their application to retrovirology.
Bieniasz, Paul D; Kutluay, Sebla B
2018-05-02
Virtually every step of HIV-1 replication and numerous cellular antiviral defense mechanisms are regulated by the binding of a viral or cellular RNA-binding protein (RBP) to distinct sequence or structural elements on HIV-1 RNAs. Until recently, these protein-RNA interactions were studied largely by in vitro binding assays complemented with genetics approaches. However, these methods are highly limited in the identification of the relevant targets of RBPs in physiologically relevant settings. Development of crosslinking-immunoprecipitation sequencing (CLIP) methodology has revolutionized the analysis of protein-nucleic acid complexes. CLIP combines immunoprecipitation of covalently crosslinked protein-RNA complexes with high-throughput sequencing, providing a global account of RNA sequences bound by a RBP of interest in cells (or virions) at near-nucleotide resolution. Numerous variants of the CLIP protocol have recently been developed, some with major improvements over the original. Herein, we briefly review these methodologies and give examples of how CLIP has been successfully applied to retrovirology research.
Using popular films to enhance classroom learning: the good, the bad, and the interesting.
Butler, Andrew C; Zaromb, Franklin M; Lyle, Keith B; Roediger, Henry L
2009-09-01
Popular history films sometimes contain major historical inaccuracies. Two experiments investigated how watching such films influences people's ability to remember associated texts. Subjects watched film clips and studied texts about various historical topics. Whereas the texts contained only correct information, the film clips contained both correct information (consistent with the text) and misinformation (contradicted by the text). Before watching each clip, subjects received a specific warning, a general warning, or no warning about the misinformation. One week later, they returned for a cued-recall test about the texts. Watching a film clip increased correct recall of consistent information relative to recall of the same information when subjects did not see the clip. However, when the information in the film contradicted the text, subjects often (falsely) recalled misinformation from the film. The specific warning substantially reduced this misinformation effect. Teachers should use popular history films with caution and should warn students about major inaccuracies in the films.
Optimizing assessment of sexual arousal in postmenopausal women using erotic film clips.
Ramos Alarcon, Lauren G; Dai, Jing; Collins, Karen; Perez, Mindy; Woodard, Terri; Diamond, Michael P
2017-10-01
This study sought to assess sexual arousal in a subgroup of women by identifying erotic film clips that would be most mentally appealing and physically arousing to postmenopausal women. By measuring levels of mental appeal and self-reported physical arousal using a bidirectional scale, we aimed to elucidate the clips that would best be utilized for sexual health research in the postmenopausal or over 50-year-old subpopulation. Our results showed that postmenopausal women did not rate clips with older versus younger actors differently (p>0.05). The mean mental and mean physical scores were significantly correlated for both premenopausal subject ratings (r=0.69, p<0.001) and postmenopausal subject ratings (r=0.94, p<0.001). Thus postmenopausal women do not show a preference for the age of actors used in erotic film clips; this knowledge is relevant for design of future sexual function research. Copyright © 2017 Elsevier B.V. All rights reserved.
iCLIP reveals the function of hnRNP particles in splicing at individual nucleotide resolution
König, Julian; Zarnack, Kathi; Rot, Gregor; Curk, Tomaž; Kayikci, Melis; Zupan, Blaž; Turner, Daniel J.; Luscombe, Nicholas M.; Ule, Jernej
2010-01-01
In the nucleus of eukaryotic cells, nascent transcripts are associated with heterogeneous nuclear ribonucleoprotein (hnRNP) particles that are nucleated by hnRNP C. Despite their abundance however, it remained unclear whether these particles control pre-mRNA processing. Here, we developed individual-nucleotide resolution UV-cross-linking and immunoprecipitation (iCLIP) to study the role of hnRNP C in splicing regulation. iCLIP data demonstrate that hnRNP C recognizes uridine tracts with a defined long-range spacing consistent with hnRNP particle organization. hnRNP particles assemble on both introns and exons, but remain generally excluded from splice sites. Integration of transcriptome-wide iCLIP data and alternative splicing profiles into an ‘RNA map’ indicates how the positioning of hnRNP particles determines their effect on inclusion of alternative exons. The ability of high-resolution iCLIP data to provide insights into the mechanism of this regulation holds promise for studies of other higher-order ribonucleoprotein complexes. PMID:20601959
Gucu, Arif; Toktas, Faruk; Eris, Cuneyt; Ata, Yusuf; Turk, Tamer
2012-01-01
Postoperative sternal dehiscence is a potentially catastrophic sequela to median sternotomy that can cause not only chest-wall discomfort and pulmonary dysfunction but infection, both superficial and mediastinal. Nitinol thermoreactive clips use a novel material in the treatment of sternal dehiscence. We sought to determine whether the use of these clips is an effective remedy for noninfective sternal dehiscence. From January 2008 through December 2011, we retrospectively studied the data on 10 patients whose sternums had been closed with nitinol thermoreactive clips after the development of noninfective sternal dehiscence. Diagnosis was made on the bases of clinical criteria, chest radiography, and microbiological investigation. There was no control group. No procedure-related sequelae occurred. There was no recurrent sternal instability and dehiscence, sternal-related hemorrhage, superficial wound infection, or mediastinal infection. We believe that the use of nitinol thermoreactive clips is a safe, easy, and efficient method of secondary sternal closure for noninfective sternal dehiscence. PMID:22949767
ERIC Educational Resources Information Center
Ryan, Christian; Furley, Philip; Mulhall, Kathleen
2016-01-01
Typically developing children are able to judge who is winning or losing from very short clips of video footage of behaviour between active match play across a number of sports. Inferences from "thin slices" (short video clips) allow participants to make complex judgments about the meaning of posture, gesture and body language. This…
A Simple Recipe for Whitening Old Newspaper Clippings
NASA Astrophysics Data System (ADS)
Carter, Henry A.
1995-07-01
Newspaper clippings tend to brown quickly with aging as the result of chromophores that form during the degradation of one or more components of paper. Newsprint that consists of approximately 40% lignin is particularly susceptible to browning due to the relative ease of the oxidation of lignin. For readers who wish to experiment with both whitening and deacidifying old newspaper clippings, a simple recipe requiring few materials is presented.
Zhang, Zijun; Xing, Yi
2017-09-19
Crosslinking or RNA immunoprecipitation followed by sequencing (CLIP-seq or RIP-seq) allows transcriptome-wide discovery of RNA regulatory sites. As CLIP-seq/RIP-seq reads are short, existing computational tools focus on uniquely mapped reads, while reads mapped to multiple loci are discarded. We present CLAM (CLIP-seq Analysis of Multi-mapped reads). CLAM uses an expectation-maximization algorithm to assign multi-mapped reads and calls peaks combining uniquely and multi-mapped reads. To demonstrate the utility of CLAM, we applied it to a wide range of public CLIP-seq/RIP-seq datasets involving numerous splicing factors, microRNAs and m6A RNA methylation. CLAM recovered a large number of novel RNA regulatory sites inaccessible by uniquely mapped reads. The functional significance of these sites was demonstrated by consensus motif patterns and association with alternative splicing (splicing factors), transcript abundance (AGO2) and mRNA half-life (m6A). CLAM provides a useful tool to discover novel protein-RNA interactions and RNA modification sites from CLIP-seq and RIP-seq data, and reveals the significant contribution of repetitive elements to the RNA regulatory landscape of the human transcriptome. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
Speed Biases With Real-Life Video Clips
Rossi, Federica; Montanaro, Elisa; de’Sperati, Claudio
2018-01-01
We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion), speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion) to 32% (physical motion). Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate “natural” video compression techniques based on sub-threshold temporal squeezing. PMID:29615875
Speed Biases With Real-Life Video Clips.
Rossi, Federica; Montanaro, Elisa; de'Sperati, Claudio
2018-01-01
We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion), speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion) to 32% (physical motion). Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate "natural" video compression techniques based on sub-threshold temporal squeezing.
Szabó, Antal; Papp, András; Borbándy, Ágnes; D Géhl, Zsuzsanna; Nagy, Zoltán Zsolt; Resch, Miklós
2017-01-01
The correction of aphakia might be a challenge for the surgeon. The aim of this study is to describe the authors' experience with the implantation of the retropupillary iris clip intraocular lens. Patients between January 2014 and December 2015 were included in the retrospective study. Retropupillary implantation of iris clip intraocular lens VRSA 54 (AMO Advanced Medical Optics, USA) was performed in all cases. The minimum follow up period was three months. The stability of the intraocular lens and the intraoperative and postoperative complications and the visual acuity were evaluated. During this time period 11 cases (1 female, 10 males) were included in the study. The mean age at the time of the implantation was 57.7 years (between 25-74 years). In 4 cases the iris clip lens was implanted during the first intervention, in 7 cases during the secondary procedure. In all cases the lens was fixated onto the iris posteriorly. The best corrected visual acuity before the iris clip implantation was 0.43 (0.1-1.0) and postoperatively at the time of the follow up 0.49 (0.04-1.0). With the use of the retropupillary implanted iris clip intraocular lens all of the patients could have been rehabilitated without major complications. Orv. Hetil., 2017, 158(1), 20-24.
Integrating Commercial Off-The-Shelf (COTS) graphics and extended memory packages with CLIPS
NASA Technical Reports Server (NTRS)
Callegari, Andres C.
1990-01-01
This paper addresses the question of how to mix CLIPS with graphics and how to overcome PC's memory limitations by using the extended memory available in the computer. By adding graphics and extended memory capabilities, CLIPS can be converted into a complete and powerful system development tool, on the other most economical and popular computer platform. New models of PCs have amazing processing capabilities and graphic resolutions that cannot be ignored and should be used to the fullest of their resources. CLIPS is a powerful expert system development tool, but it cannot be complete without the support of a graphics package needed to create user interfaces and general purpose graphics, or without enough memory to handle large knowledge bases. Now, a well known limitation on the PC's is the usage of real memory which limits CLIPS to use only 640 Kb of real memory, but now that problem can be solved by developing a version of CLIPS that uses extended memory. The user has access of up to 16 MB of memory on 80286 based computers and, practically, all the available memory (4 GB) on computers that use the 80386 processor. So if we give CLIPS a self-configuring graphics package that will automatically detect the graphics hardware and pointing device present in the computer, and we add the availability of the extended memory that exists in the computer (with no special hardware needed), the user will be able to create more powerful systems at a fraction of the cost and on the most popular, portable, and economic platform available such as the PC platform.
Saji, Mike; Rossi, Ann M; Ailawadi, Gorav; Dent, John; Ragosta, Michael; Lim, D Scott
2016-02-01
We evaluated intracardiac echocardiography (ICE) for adjunctively guiding the MitraClip procedure in patients with prior surgical rings. Transesophageal echocardiography (TEE) is the standard imaging modality used to guide the MitraClip procedure (Abbott Vascular, CA). However, in patients with post-surgical anatomy, clear imaging of the mitral valve leaflets may be complex because of shadowing from the surgical ring. In these patients, TEE may be suboptimal for guiding the procedure, even using three-dimensional imaging. This retrospective analysis included data from 121 consecutive patients with mitral regurgitation who underwent MitraClip procedures at the University of Virginia. ICE was used adjunctively when there was difficulty with TEE, particularly for assessing the insertion of the posterior leaflet into the MitraClip's arms. The ICE catheter was introduced transarterially into the left ventricle and flexed to obtain the short-axis view. Six patients had prior surgical rings, and in five, we used adjunctive ICE. The etiology of the mitral regurgitation was prolapse of the posterior leaflet in one patient and restriction of the posterior leaflet due to ischemic tethering in the remainder. All images were obtained from the left ventricle, and were adequate for assessing posterior leaflet insertion and the perpendicularity of the MitraClip arms. The procedural success rate was 80%. There was no adverse event related to the ICE procedure. Mitral valve repair with the MitraClip system assisted by ICE is feasible in patients with prior surgical rings, achieving an excellent risk profile and satisfactory procedural success. © 2015 Wiley Periodicals, Inc.
Yan, Shi; Wang, Xing; Lv, Chao; Phan, Kevin; Wang, Yuzhao; Wang, Jia; Yang, Yue
2016-01-01
Background Postoperative pleural drainage markedly influences the length of postoperative stay and financial costs of medical care. The aim of this study is to retrospectively investigate potentially predisposing factors related to pleural drainage after curative thoracic surgery and to explore the impact of mediastinal micro-vessels clipping on pleural drainage control after lymph node dissection. Methods From February 2012 to November 2013, 322 consecutive cases of operable non-small cell lung cancers (NSCLC) undergoing lobectomy and mediastinal lymph node dissection with or without application of clipping were collected. Total and daily postoperative pleural drainage were recorded. Propensity score matching (1:2) was applied to balance variables potentially impacting pleural drainage between group clip and group control. Analyses were performed to compare drainage volume, duration of chest tube and postoperative hospital stay between the two groups. Variables linked with pleural drainage in whole cohort were assessed using multivariable logistic regression analysis. Results Propensity score matching resulted in 197 patients (matched cohort). Baseline patient characteristics were matched between two groups. Group clip showed less cumulative drainage volume (P=0.020), shorter duration of chest tube (P=0.031) and postoperative hospital stay (P=0.022) compared with group control. Risk factors significantly associated with high-output drainage in multivariable logistic regression analysis were being male, age >60 years, bilobectomy/sleeve lobectomy, pleural adhesion, the application of clip applier, duration of operation ≥220 minutes and chylothorax (P<0.05). Conclusions This study suggests that mediastinal micro-vessels clipping during lymph node dissection may reduce postoperative pleural drainage and thus shorten hospital stay. PMID:27076936
The effects of media violence on anxiety in late adolescence.
Madan, Anjana; Mrug, Sylvie; Wright, Rex A
2014-01-01
Exposure to media violence is related to anxiety in youth, but the causality of the effect has not been established. This experimental study examined the effects of media violence on anxiety, blood pressure, and heart rate in late adolescents. We also examined whether these responses varied by previous exposure to media and real-life violence. College students (N = 209; M age = 18.74; 75 % female; 50 % Caucasian, 34 % African American, 9 % Asian, 3 % Hispanic, and 3 % other racial minorities) were randomized to view either violent or nonviolent high-action movie clips. Participants reported on their anxiety before and after watching the clips, as well as their previous exposure to violence. Measures of blood pressure and heart rate were taken at baseline and during movie viewing. Participants watching violent movie clips showed a greater anxiety increase than those watching nonviolent clips. Both groups experienced increased blood pressure and reduced heart rate during movie watching compared to baseline. Prior exposure to media violence was associated with diminished heart rate response. Additionally, students previously exposed to high levels of real-life violence showed lower blood pressure increases when watching violent clips compared to nonviolent clips. Thus, relatively brief exposure to violent movie clips increased anxiety among late adolescents. Prior exposure to media and real-life violence were associated with lower physiological reactivity to high-action and violent movies, respectively, possibly indicating desensitization. Future studies should investigate long-term anxiety and physiological consequences of regular exposure to media violence in adolescence.
A P300 event related potential technique for assessment of sexually oriented interest.
Vardi, Yoram; Volos, Michal; Sprecher, Elliot; Granovsky, Yelena; Gruenwald, Ilan; Yarnitsky, David
2006-12-01
Despite all of the modern, sophisticated tests that exist for diagnosing and assessing male and female sexual disorders, to our knowledge there is no objective psychophysiological test to evaluate sexual arousal and interest. We provide preliminary data showing a decrease in auditory P300 wave amplitude during exposure to sexually explicit video clips and a significant correlation between the auditory P300 amplitude decrease and self-reported scores of sexual arousal and interest in the clips. A total of 30 healthy subjects were exposed to several blocks of auditory stimuli administered using an oddball paradigm. Baseline auditory P300 amplitudes were obtained and auditory stimuli were then delivered while viewing visual clips with 3 types of content, including sport, scenery and sex. Auditory P300 amplitude significantly decreased during viewing clips of all contents. Viewing sexual content clips caused a maximal decrease in P300 amplitude (p <0.0001). In addition, a high correlation was found between the amplitude decrease and scores on the sexual arousal questionnaire regarding the viewed clips (r = 0.61, p <0.001). In addition, the P300 amplitude decrease was significantly related to the sexual interest score (r = 0.37, p = 0.042) but not to interest in clips of nonsexual content. The change in auditory P300 amplitude during exposure to visual stimuli with sexual context seems to be an objective measure of subject sexual interest. This method might be applied to assess therapeutic intervention and as a diagnostic tool for assessing disorders of impaired libido or psychogenic sexual dysfunction.
Hokari, Masaaki; Kazumara, Ken; Nakayama, Naoki; Ushikoshi, Satoshi; Sugiyama, Taku; Asaoka, Katsunori; Uchida, Kazuki; Shimbo, Daisuke; Itamoto, Koji; Yokoyama, Yuka; Isobe, Masanori; Imai, Tetsuaki; Osanai, Toshiya; Houkin, Kiyohiro
2016-08-01
There are no established treatment strategies for aneurysms that recur after clipping. In this study, we present cases of patients who experienced recurrent aneurysms after clipping and subsequently underwent surgical intervention. Between 2004 and 2015, we surgically treated 23 aneurysms that recurred at a previously clipped site. Patient characteristics and clinical history were retrospectively reviewed. Patients included 19 women and 4 men 45-81 years old. Aneurysms recurred 3-31 years (mean, 15.4 years) after the initial operation. For 18 cases, the first clinical presentation was a subarachnoid hemorrhage; aneurysms were incidentally diagnosed in 5 patients. Aneurysm locations were as follows: 9 on the internal carotid artery; 4 on the middle cerebral artery; 7 on the anterior communicating artery; 2 on the distal anterior cerebral artery; and 1 on the basilar artery. The reasons for retreatment included subarachnoid hemorrhage (n = 9) and aneurysm regrowth detected on follow-up examinations (n = 14). Endovascular treatment was performed in 10 cases, and direct surgery was performed in 13 cases (clipping in 8, clipping or trapping with bypass in 5). Various complex vascular reconstructions, including high-flow bypass and intracranial-intracranial in situ bypass, were performed for recurrent aneurysms. In our experience, coil embolization is a safe and effective procedure for treating recurrent aneurysms. When cases are unsuitable for coil embolization, surgical treatment often requires neurosurgeons not only to overcome the general technical difficulty of reoperative clipping but also to perform challenging vascular reconstruction. Copyright © 2016. Published by Elsevier Inc.
Pfleeger, Adam Z; Eagles-Smith, Collin A; Kowalski, Brandon M; Herring, Garth; Willacker, James J; Jackson, Allyson K; Pierce, John R
2016-04-01
Exposure to environmental contaminants has been implicated as a factor in global amphibian decline. Mercury (Hg) is a particularly widespread contaminant that biomagnifies in amphibians and can cause a suite of deleterious effects. However, monitoring contaminant exposure in amphibian tissues may conflict with conservation goals if lethal take is required. Thus, there is a need to develop non-lethal tissue sampling techniques to quantify contaminant exposure in amphibians. Some minimally invasive sampling techniques, such as toe-clipping, are common in population-genetic research, but it is unclear if these methods can adequately characterize contaminant exposure. We examined the relationships between mercury (Hg) concentrations in non-lethally sampled tissues and paired whole-bodies in five amphibian species. Specifically, we examined the utility of three different tail-clip sections from four salamander species and toe-clips from one anuran species. Both tail and toe-clips accurately predicted whole-body THg concentrations, but the relationships differed among species and the specific tail-clip section or toe that was used. Tail-clips comprised of the distal 0-2 cm segment performed the best across all salamander species, explaining between 82 and 92% of the variation in paired whole-body THg concentrations. Toe-clips were less effective predictors of frog THg concentrations, but THg concentrations in outer rear toes accounted for up to 79% of the variability in frog whole-body THg concentrations. These findings suggest non-lethal sampling of tails and toes has potential applications for monitoring contaminant exposure and risk in amphibians, but care must be taken to ensure consistent collection and interpretation of samples.
Training in Cerebral Aneurysm Clipping Using Self-Made 3-Dimensional Models.
Mashiko, Toshihiro; Kaneko, Naoki; Konno, Takehiko; Otani, Keisuke; Nagayama, Rie; Watanabe, Eiju
Recently, there have been increasingly fewer opportunities for junior surgeons to receive on-the-job training. Therefore, we created custom-built three-dimensional (3D) surgical simulators for training in connection with cerebral aneurysm clipping. Three patient-specific models were composed of a trimmed skull, retractable brain, and a hollow elastic aneurysm with its parent artery. The brain models were created using 3D printers via a casting technique. The artery models were made by 3D printing and a lost-wax technique. Four residents and 2 junior neurosurgeons attended the training courses. The trainees retracted the brain, observed the parent arteries and aneurysmal neck, selected the clip(s), and clipped the neck of an aneurysm. The duration of simulation was recorded. A senior neurosurgeon then assessed the trainee's technical skill and explained how to improve his/her performance for the procedure using a video of the actual surgery. Subsequently, the trainee attempted the clipping simulation again, using the same model. After the course, the senior neurosurgeon assessed each trainee's technical skill. The trainee critiqued the usefulness of the model and the effectiveness of the training course. Trainees succeeded in performing the simulation in line with an actual surgery. Their skills tended to improve upon completion of the training. These simulation models are easy to create, and we believe that they are very useful for training junior neurosurgeons in the surgical techniques needed for cerebral aneurysm clipping. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
21 CFR 884.1720 - Gynecologic laparoscope and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...
21 CFR 884.1720 - Gynecologic laparoscope and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...
21 CFR 884.1720 - Gynecologic laparoscope and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hasan, Yasmin; Kim, Leonard; Martinez, Alvaro
Purpose: To compare localization of the lumpectomy cavity by using breast surface matching vs. clips for image-guided external beam accelerated partial breast irradiation. Methods and Materials: Twenty-seven patients with breast cancer with two computed tomography (CT) scans each had three CT registrations performed: (1) to bony anatomy, (2) to the center of mass (COM) of surgical clips, and (3) to the breast surface. The cavity COM was defined in both the initial and second CT scans after each type of registration, and distances between COMs ({delta}COM{sub Bone}, {delta}COM{sub Clips}, and {delta}COM{sub Surface}) were determined. Smaller {delta}COMs were interpreted as bettermore » localizations. Correlation coefficients were calculated for {delta}COM vs. several variables. Results: The {delta}COM{sub Bone} (mean, 7 {+-} 2 [SD] mm) increased with breast volume (r = 0.4; p = 0.02) and distance from the chest wall (r = 0.5; p = 0.003). Relative to bony registration, clip registration provided better localization ({delta}COM{sub Clips} < {delta}COM{sub Bone}) in 25 of 27 cases. Breast surface matching improved cavity localization ({delta}COM{sub Surface} < {delta}COM{sub Bone}) in 19 of 27 cases. Mean improvements ({delta}COM{sub Bone} - {delta}COM{sub ClipsorSurface}) were 4 {+-} 3 and 2 {+-} 4 mm, respectively. In terms of percentage of improvement ([{delta}COM{sub Bone} - {delta}COM{sub ClipsorSurface}]/{delta}COM{sub Bone}), only surface matching showed a correlation with breast volume. Clip localization outperformed surface registration for cavities located superior to the breast COM. Conclusions: Use of either breast surface or surgical clips as surrogates for the cavity results in improved localization in most patients compared with bony registration and may allow smaller planning target volume margins for external beam accelerated partial breast irradiation. Compared with surface registration, clip registration may be less sensitive to anatomic characteristics and therefore more broadly applicable.« less
Shi, Lei; Yu, Jing; Zhao, Ying; Xu, Kan; Yu, Jinlu
2018-01-01
It is widely acknowledged that arteriosclerosis and calcification of the parent artery and aneurysm neck make it difficult to clip posterior communicating artery (PCoA) aneurysms. A total of 136 cases of PCoA aneurysms accompanied by arteriosclerosis and calcification were collected and treated with clipping in the present study. Of the 136 patients, 112 were females (82.4%) and 24 were males (17.6%), with ages ranging from 37 to 76 years (mean age, 60.2 years). Rupture of a PCoA aneurysm was identified in 132 cases (97.1%), and there were 4 cases of unruptured PCoA aneurysms (2.9%). According to the severity of arteriosclerosis and calcification, the aneurysms were divided into type I, II or III. The treatment of type I aneurysms achieved the best curative effect. It is difficult to temporarily occlude type II and III aneurysms during surgery, and temporary occlusion failed in almost 50% of cases. Types II and III were prone to intraoperative aneurysm ruptures. A significantly higher rate of intraoperative aneurysm rupture was seen in type III compared with type II cases. Type II and III cases were more likely to be treated using a fenestrated clip for aneurysm clipping compared with type I cases, and fenestrated clips were used significantly more frequently in type III cases compared with type II cases. Arteriosclerosis and calcification were likely to affect the prognosis of patients, particularly in cases with type III arteriosclerosis and calcification of the parent artery and aneurysm neck. Therefore, the stratification of the arteriosclerosis and calcification of the parent artery and aneurysm neck into types I–III can guide the intraoperative aneurysm clipping strategy, aid in choosing the correct clips, and inform predictions of the occurrence of rupture and hemorrhage, as well as the prognosis for aneurysms. PMID:29434749
Shi, Lei; Yu, Jing; Zhao, Ying; Xu, Kan; Yu, Jinlu
2018-02-01
It is widely acknowledged that arteriosclerosis and calcification of the parent artery and aneurysm neck make it difficult to clip posterior communicating artery (PCoA) aneurysms. A total of 136 cases of PCoA aneurysms accompanied by arteriosclerosis and calcification were collected and treated with clipping in the present study. Of the 136 patients, 112 were females (82.4%) and 24 were males (17.6%), with ages ranging from 37 to 76 years (mean age, 60.2 years). Rupture of a PCoA aneurysm was identified in 132 cases (97.1%), and there were 4 cases of unruptured PCoA aneurysms (2.9%). According to the severity of arteriosclerosis and calcification, the aneurysms were divided into type I, II or III. The treatment of type I aneurysms achieved the best curative effect. It is difficult to temporarily occlude type II and III aneurysms during surgery, and temporary occlusion failed in almost 50% of cases. Types II and III were prone to intraoperative aneurysm ruptures. A significantly higher rate of intraoperative aneurysm rupture was seen in type III compared with type II cases. Type II and III cases were more likely to be treated using a fenestrated clip for aneurysm clipping compared with type I cases, and fenestrated clips were used significantly more frequently in type III cases compared with type II cases. Arteriosclerosis and calcification were likely to affect the prognosis of patients, particularly in cases with type III arteriosclerosis and calcification of the parent artery and aneurysm neck. Therefore, the stratification of the arteriosclerosis and calcification of the parent artery and aneurysm neck into types I-III can guide the intraoperative aneurysm clipping strategy, aid in choosing the correct clips, and inform predictions of the occurrence of rupture and hemorrhage, as well as the prognosis for aneurysms.
Hemodynamic response during aneurysm clipping surgery among experienced neurosurgeons.
Bunevicius, Adomas; Bilskiene, Diana; Macas, Andrius; Tamasauskas, Arimantas
2016-02-01
Neurosurgery is a challenging field associated with high levels of mental stress. The goal of this study was to investigate the hemodynamic response of experienced neurosurgeons during aneurysm clipping surgery and to evaluate whether neurosurgeons' hemodynamic responses are associated with patients' clinical statuses. Four vascular neurosurgeons (all male; mean age 51 ± 10 years; post-residency experience ≥7 years) were studied during 42 aneurysm clipping procedures. Blood pressure (BP) and heart rate (HR) were assessed at rest and during seven phases of surgery: before the skin incision, after craniotomy, after dural opening, after aneurysm neck dissection, after aneurysm clipping, after dural closure and after skin closure. HR and BP were significantly greater during surgery relative to the rest situation (p ≤ 0.03). There was a statistically significant increase in neurosurgeons' HR (F [6, 41] = 10.88, p < 0.001), systolic BP (F [6, 41] = 2.97, p = 0.01), diastolic BP (F [6, 41] = 2.49, p = 0.02) and mean BP (F [6, 41] = 3.36, p = 0.003) during surgery. The greatest mean HR was after aneurysm clipping, and the greatest BP was after aneurysm neck dissection. Systolic, diastolic and mean BPs were significantly greater during surgical clipping for unruptured aneurysms compared to ruptured aneurysms across all stages of surgery (p ≤ 0.002); however, after adjusting for neurosurgeon experience, the difference in BP as a function of aneurysm rupture was not significant (p > 0.08). Aneurysm location, intraoperative aneurysm rupture, admission WFNS score, admission Glasgow Coma Scale scores and Fisher grade were not associated with neurosurgeons' intraoperative HR and BP (all p > 0.07). Aneurysm clipping surgery is associated with significant hemodynamic system activation among experienced neurosurgeons. The greatest HR and BP were after aneurysm neck dissection and clipping. Aneurysm location and patient clinical status were not associated with intraoperative changes of neurosurgeons' HR and BP.
Carvalho, Sandra; Leite, Jorge; Galdo-Álvarez, Santiago; Gonçalves, Óscar F.
2011-01-01
Some authors have speculated that the cognitive component (P3) of the Event-Related Potential (ERP) can function as a psychophysiological measure of sexual interest. The aim of this study was to determine if the P3 ERP component in a workload task can be used as a specific and objective measure of sexual motivation by comparing the neurophysiologic response to stimuli of motivational relevance with different levels of valence and arousal. A total of 30 healthy volunteers watched different films clips with erotic, horror, social-positive and social-negative content, while answering an auditory oddball paradigm. Erotic film clips resulted in larger interference when compared to both the social-positive and auditory alone conditions. Horror film clips resulted in the highest levels of interference with smaller P3 amplitudes than erotic and also than social-positive, social-negative and auditory alone condition. No gender differences were found. Both horror and erotic film clips significantly decreased heart rate (HR) when compared to both social-positive and social-negative films. The erotic film clips significantly increased the skin conductance level (SCL) compared to the social-negative films. The horror film clips significantly increased the SCL compared to both social-positive and social-negative films. Both the highly arousing erotic and non-erotic (horror) movies produced the largest decrease in the P3 amplitude, a decrease in the HR and an increase in the SCL. These data support the notion that this workload task is very sensitive to the attentional resources allocated to the film clip, although they do not act as a specific index of sexual interest. Therefore, the use of this methodology seems to be of questionable utility as a specific measure of sexual interest or as an objective measure of the severity of Hypoactive Sexual Desire Disorder. PMID:22216305
Carvalho, Sandra; Leite, Jorge; Galdo-Álvarez, Santiago; Gonçalves, Oscar F
2011-01-01
Some authors have speculated that the cognitive component (P3) of the Event-Related Potential (ERP) can function as a psychophysiological measure of sexual interest. The aim of this study was to determine if the P3 ERP component in a workload task can be used as a specific and objective measure of sexual motivation by comparing the neurophysiologic response to stimuli of motivational relevance with different levels of valence and arousal. A total of 30 healthy volunteers watched different films clips with erotic, horror, social-positive and social-negative content, while answering an auditory oddball paradigm. Erotic film clips resulted in larger interference when compared to both the social-positive and auditory alone conditions. Horror film clips resulted in the highest levels of interference with smaller P3 amplitudes than erotic and also than social-positive, social-negative and auditory alone condition. No gender differences were found. Both horror and erotic film clips significantly decreased heart rate (HR) when compared to both social-positive and social-negative films. The erotic film clips significantly increased the skin conductance level (SCL) compared to the social-negative films. The horror film clips significantly increased the SCL compared to both social-positive and social-negative films. Both the highly arousing erotic and non-erotic (horror) movies produced the largest decrease in the P3 amplitude, a decrease in the HR and an increase in the SCL. These data support the notion that this workload task is very sensitive to the attentional resources allocated to the film clip, although they do not act as a specific index of sexual interest. Therefore, the use of this methodology seems to be of questionable utility as a specific measure of sexual interest or as an objective measure of the severity of Hypoactive Sexual Desire Disorder. © 2011 Carvalho et al.
21 CFR 884.1640 - Culdoscope and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... instruments include: lens cleaning brush, biopsy brush, clip applier (without clips), applicator, cannula... (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable) scissors, and suction/irrigation...
21 CFR 884.1640 - Culdoscope and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... instruments include: lens cleaning brush, biopsy brush, clip applier (without clips), applicator, cannula... (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable) scissors, and suction/irrigation...
21 CFR 884.1640 - Culdoscope and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... instruments include: lens cleaning brush, biopsy brush, clip applier (without clips), applicator, cannula... (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable) scissors, and suction/irrigation...
Piezoelectric resonator assembly with thin molybdenum mounting clips
Peters, R. Donald
1981-01-01
A resonator mounting assembly wherein the resonator blank is mounted agai an essentially planar surface presented by a plurality of peripherally disposed mounting clips and bonded to this surface to provide substantially all the mechanical support for the blank in a direction normal to the major faces of the resonator blank, while being flexible in the directions parallel to said major faces so as to minimize radial stresses on the resonator blank, particularly during thermal cycling of the resonator assembly. The clips are fabricated of a low thermal expansion material, such as molybdenum, which also has considerable yield strength after exposure to processing temperatures; the bonding of the clips to the edges of the resonator blank can be achieved by a polyimide containing electrically conductive particles.
NASA Technical Reports Server (NTRS)
Hruska, S. I.; Dalke, A.; Ferguson, J. J.; Lacher, R. C.
1991-01-01
Rule-based expert systems may be structurally and functionally mapped onto a special class of neural networks called expert networks. This mapping lends itself to adaptation of connectionist learning strategies for the expert networks. A parsing algorithm to translate C Language Integrated Production System (CLIPS) rules into a network of interconnected assertion and operation nodes has been developed. The translation of CLIPS rules to an expert network and back again is illustrated. Measures of uncertainty similar to those rules in MYCIN-like systems are introduced into the CLIPS system and techniques for combining and hiring nodes in the network based on rule-firing with these certainty factors in the expert system are presented. Several learning algorithms are under study which automate the process of attaching certainty factors to rules.
Image recognition of clipped stigma traces in rice seeds
NASA Astrophysics Data System (ADS)
Cheng, F.; Ying, YB
2005-11-01
The objective of this research is to develop algorithm to recognize clipped stigma traces in rice seeds using image processing. At first, the micro-configuration of clipped stigma traces was observed with electronic scanning microscope. Then images of rice seeds were acquired with a color machine vision system. A digital image-processing algorithm based on morphological operations and Hough transform was developed to inspect the occurrence of clipped stigma traces. Five varieties of Jinyou402, Shanyou10, Zhongyou207, Jiayou and you3207 were evaluated. The algorithm was implemented with all image sets using a Matlab 6.5 procedure. The results showed that the algorithm achieved an average accuracy of 96%. The algorithm was proved to be insensitive to the different rice seed varieties.
Alexander, David J.
1994-01-01
An attachment for placement between a test specimen and a remote clip gage extensometer providing improved fracture toughness tests of materials at elevated temperature. Using a cylindrical tube and axial rod in new relationship, the device transfers the displacement signal of the fracture toughness test specimen directly to a clip gage extensometer located outside the high temperature furnace. Virtually frictionless operation is assured by having the test specimen center one end of the rod in one end of the tube, while the clip gage extensometer arms center the other end of the rod in the other end of the tube. By providing positive control over both ends of both rod and tube, the attachment may be operated in orientations other than vertical.
Park, Yong Sook; Nam, Taek Kyun
2017-03-01
We describe a technique to clip a large internal carotid artery (ICA) aneurysm via a retrograde suction decompression (RSD). A large aneurysm in the right distal ICA involving the bifurcation region measuring 1.2×1.1×0.7 cm with posterior projection was managed with assisted RSD technique. The anterior choroidal artery emerged from the side wall of the aneurysm. An Inahara shunt was inserted into the ICA with neck dissection, and RSD was applied after completely clipping the aneurysm. RSD with an Inahara carotid shunt is useful for complete visualization of the aneurysm, including its surrounding structures, and for proximal control of the parent vessels, subsequently achieving satisfactory clip placement.
NASA Astrophysics Data System (ADS)
Hao, J.; Zhang, J. H.; Yao, Z. X.
2017-12-01
We developed a method to restore the clipped seismic waveforms near epicenter using projection onto convex sets method (Zhang et al, 2016). This method was applied to rescue the local clipped waveforms of 2013 Mw 6.6 Lushan earthquake. We restored 88 out of 93 clipped waveforms of 38 broadband seismic stations of China Earthquake Networks (CEN). The epicenter distance of the nearest station to the epicenter that we can faithfully restore is only about 32 km. In order to investigate if the source parameters of earthquake could be determined exactly with the restored data, restored waveforms are utilized to get the mechanism of Lushan earthquake. We apply the generalized reflection-transmission coefficient matrix method to calculate the synthetic seismic records and simulated annealing method in inversion (Yao and Harkrider, 1983; Hao et al., 2012). We select 5 stations of CEN with the epicenter distance about 200km whose records aren't clipped and three-component velocity records are used. The result shows the strike, dip and rake angles of Lushan earthquake are 200o, 51o and 87o respectively, hereinafter "standard result". Then the clipped and restored seismic waveforms are applied respectively. The strike, dip and rake angles of clipped seismic waveforms are 184o, 53o and 72o respectively. The largest misfit of angle is 16o. In contrast, the strike, dip and rake angles of restored seismic waveforms are 198o, 51o and 87o respectively. It is very close to the "standard result". We also study the rupture history of Lushan earthquake constrained with the restored local broadband and teleseismic waves based on finite fault method (Hao et al., 2013). The result consists with that constrained with the strong motion and teleseismic waves (Hao et al., 2013), especially the location of the patch with larger slip. In real-time seismology, determining the source parameters as soon as possible is important. This method will help us to determine the mechanism of earthquake using the local clipped waveforms. Strong motion stations in China don't have good coverage at present. This method will help us to investigate the rupture history of large earthquake in China using the local clipped data of broadband stations.
CLIPSITS - CLIPS INTELLIGENT TUTORING SYSTEM
NASA Technical Reports Server (NTRS)
Riley, G.
1994-01-01
The CLIPS Intelligent Tutoring System (CLIPSITS) is designed to be used to learn CLIPS, the C-language Integrated Production System expert system shell developed by the Software Technology Branch at Johnson Space Center. The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. This version of CLIPSITS is compatible with the Version 4.2 and 4.3 CLIPS User's Guide. However, the program does not cover any new features of CLIPS v4.3 that were added since the release of v4.2. The chapter numbers in the CLIPS User's Guide correspond directly with the lesson numbers in CLIPSITS. Each lesson in the program contains anywhere from 1 to 10 problems. Most of these have multiple parts. The student is given a subset of these problems from each lesson to work. The actual number of problems presented depends on how well the student masters the previous problem(s). The progression through these lessons is maintained in a personalized file under the student's name. As with most computer languages, there is usually more than one way to solve a problem. CLIPSITS attempts to be as flexible as possible and to allow as many correct solutions as possible. CLIPSITS gives the student the option of setting his/her own colors for the screen interface and the option of redefining special keystroke combinations used within the program. CLIPSITS requires an IBM PC compatible with 640K RAM and optional 2 or 3 button mouse. A 286- or 386-based machine is preferable. Performance will be somewhat slower on an XT class machine. The program must be installed on a hard disk with 825 KB space available. The program was developed in 1989. The standard distribution media is three 5.25" IBM PC DOS format diskettes. The program is also sold bundled with CLIPS for a special combined price as COS-10025. NOTE: Only the executable code is distributed. Supporting documentation is included on the diskettes. IBM, IBM PC and XT are registered trademarks of International Business Machines Corporation.
Future of clip-on weapon sights: pros and cons from an applications perspective
NASA Astrophysics Data System (ADS)
Knight, C. Reed; Greenslade, Ken; Francisco, Glen
2015-05-01
US Domestic, International, allied Foreign National Warfighters and Para-Military First Responders (Police, SWAT, Special Operations, Law Enforcement, Government, Security and more) are put in harm's way all the time. To successfully complete their missions and return home safely are the primary goals of these professionals. Tactical product improvements that affect mission effectiveness and solider survivability are pivotal to understanding the past, present and future of Clip-On in-line weapon sights. Clip-On Weapon Sight (WS) technology was deemed an interim solution by the US Government for use until integrated and fused (day/night multi-sensor) Weapon Sights (WSs) were developed/fielded. Clip-On has now become the solution of choice by Users, Warriors, Soldiers and the US Government. SWaP-C (size, weight and power -cost) has been improved through progressive advances in Clip-On Image Intensified (I2), passive thermal, LL-CMOS and fused technology. Clip-On Weapon Sights are now no longer mounting position sensitive. Now they maintain aim point boresight, so they can be used for longer ranges with increased capabilities while utilizing the existing zeroed weapon and daysight optic. Active illuminated low-light level (both analog I2 and digital LL-CMOS) imaging is rightfully a real-world technology, proven to deliver daytime and low-light level identification confidence. Passive thermal imaging is also a real-world technology, proven to deliver daytime, nighttime and all-weather (including dirty battlefield) target detection confidence. Image processing detection algorithms with intelligent analytics provide documented promise to improve confidence by reducing Users, Warriors and Soldiers' work-loads and improving overall system engagement solution outcomes. In order to understand the future of Clip-On in-line weapon sights, addressing pros and cons, this paper starts with an overview of historical weapon sight applications, technologies and stakeholder decisions driving milestone events that helped shape the Clip-On weapon sight industry. Then, this paper systematically reviews current attributes of integrated multispectral wavelength electro-optical imaging systems that successfully (and sometimes unsuccessfully) shape today's Warrior, Soldier and User's net-capabilities. Finally, this paper explores the evolution, pros and cons, of future Clip-On weapon sights, from a manufacturing and real world applications perspective for tomorrow's military soldier and paramilitary first responder.
Hindman, Bradley J; Bayman, Emine O; Pfisterer, Wolfgang K; Torner, James C; Todd, Michael M
2010-01-01
Although hypothermia and barbiturates improve neurologic outcomes in animal temporary focal ischemia models, the clinical efficacy of these interventions during temporary occlusion of the cerebral vasculature during intracranial aneurysm surgery (temporary clipping) is not established. A post hoc analysis of patients from the Intraoperative Hypothermia for Aneurysm Surgery Trial who underwent temporary clipping was performed. Univariate and multivariate logistic regression methods were used to test for associations between hypothermia, supplemental protective drug, and short- (24-h) and long-term (3-month) neurologic outcomes. An odds ratio more than 1 denotes better outcome. Patients undergoing temporary clipping (n = 441) were assigned to intraoperative hypothermia (33.3 degrees +/- 0.8 degrees C, n = 208) or normothermia (36.7 degrees +/- 0.5 degrees C, n = 233), with 178 patients also receiving supplemental protective drug (thiopental or etomidate) during temporary clipping. Three months after surgery, 278 patients (63%) had good outcome (Glasgow Outcome Score = 1). Neither hypothermia (P = 0.847; odds ratio = 1.043, 95% CI = 0.678-1.606) nor supplemental protective drug (P = 0.835; odds ratio = 1.048, 95% CI = 0.674-1.631) were associated with 3-month Glasgow Outcome Score. The effect of supplemental protective drug did not significantly vary with temperature. The effects of hypothermia and protective drug did not significantly vary with temporary clip duration. Similar findings were made for 24-h neurologic status and 3-month Neuropsychological Composite Score. In the Intraoperative Hypothermia for Aneurysm Surgery Trial, neither systemic hypothermia nor supplemental protective drug affected short- or long-term neurologic outcomes of patients undergoing temporary clipping.
Suitable closure for post-duodenal endoscopic resection taking medical costs into consideration
Mori, Hirohito; Ayaki, Maki; Kobara, Hideki; Fujihara, Shintaro; Nishiyama, Noriko; Matsunaga, Tae; Yachida, Tatsuo; Masaki, Tsutomu
2015-01-01
AIM: To compare closure methods, closure times and medical costs between two groups of patients who had post-endoscopic resection (ER) artificial ulcer floor closures. METHODS: Nineteen patients with duodenal adenoma, early duodenal cancer, and subepithelial tumors that received ER between September 2009 and September 2014 at Kagawa University Hospital and Ehime Rosai Hospital, an affiliated hospital of Kagawa University, were included in the study. We retrospectively compared two groups of patients who received post-ER artificial ulcer floor closure: the conventional clip group vs the over-the-scope clip (OTSC) group. Delayed bleeding, procedure time of closure, delayed perforation, total number of conventional clips and OTSCs and medical costs were analyzed. RESULTS: Although we observed delayed bleeding in three patients in the conventional clip group, we observed no delayed bleeding in the OTSC group (P = 0.049). We did not observe perforation in either group. The mean procedure times for ulcer closure were 33.26 ± 12.57 min and 9.71 ± 2.92 min, respectively (P = 0.0001). The resection diameters were 18.8 ± 1.30 mm and 22.9 ± 1.21 mm for the conventional clip group and the OTSC group, respectively, with significant difference (P = 0.039). As for medical costs, the costs of all conventional clips were USD $1257 and the costs of OTSCs were $7850 (P = 0.005). If the post-ER ulcer is under 20 mm in diameter, a conventional clip closure may be more suitable with regard to the prevention of delayed perforation and to medical costs. CONCLUSION: If the post-ER ulcer is over 20 mm, the OTSC closure should be selected with regard to safety and reliable closure even if there are high medical costs. PMID:25954101
Asgar, Anita W; Khairy, Paul; Guertin, Marie-Claude; Cournoyer, Daniel; Ducharme, Anique; Bonan, Raoul; Basmadjian, Arsene; Tardif, Jean-Claude; Cohen, David J
2017-01-01
Mitral regurgitation (MR) is a common valvular heart disorder requiring intervention once it becomes severe. Transcatheter mitral repair with the MitraClip device is a safe and effective therapy for selected patients denied surgery. The authors sought to evaluate the clinical outcomes and economic impact of this therapy compared to medical management in heart-failure patients with symptomatic mitral regurgitation. The study was comprised of two phases; an observational study of patients with heart failure and mitral regurgitation treated with either medical therapy or the MitraClip, and an economic model. Results of the observational study were used to estimate parameters for the decision model, which estimated costs, and benefits in a hypothetical cohort of patients with heart failure and moderate-to-severe mitral regurgitation treated with either standard medical therapy or MitraClip. The cohort of patients treated with the MitraClip was propensity matched to a population of heart failure patients, and their outcomes compared. At a mean follow-up of 22 months, all-cause mortality was 21% in the MitraClip cohort and 42% in the medical management cohort (p = .007). The decision model demonstrated that MitraClip increased life expectancy from 1.87-3.60 years and quality-adjusted life years (QALY) from 1.13-2.76 years. The incremental cost was $52,500 Canadian dollars, corresponding to an incremental cost-effectiveness ratio (ICER) of $32,300.00 per QALY gained. Results were sensitive to the survival benefit. In heart failure patients with symptomatic moderate-severe mitral regurgitation, therapy with the MitraClip is associated with superior survival and is cost-effective compared to medical therapy.
He, Feng; Wang, Kun; Hannaway, David B; Li, Xianglin
2017-01-01
Leymus chinensis (Trin.) is the dominant vegetation type in eastern Eurasian temperate grasslands but is decreasing due to the combined pressure of reduced precipitation and overgrazing. This study evaluated the separate and combined effects of precipitation and defoliation on net primary productivity (NPP) and composition of a L. chinensis steppe to promote the sustainable development of temperate grasslands through improved management practices. The effects of three precipitation gradients (precipitation unchanged, reduced by 50%, and increased by 50%) and two clipping intensities (clipping once or twice per year) were examined on NPP and composition of the L. chinensis community using a 7-year in situ controlled trial at the Guyuan State Key Monitoring and Research Station of Grassland Ecosystem in China. The results showed that: (1) a 50% reduction in natural precipitation significantly decreased NPP; a 50% increase in precipitation did not significantly increase NPP, but it decreased the importance value of L. chinensis because more water promoted the growth of competing species. (2) Clipping twice per year increased NPP, but the increase was from the dry matter of other species (DMO) component, and not from the dry matter of L. chinensis. (3) The standardized coefficients of a regression model (β) for DMO, NPP, and the importance value of L. chinensis were 0.685, 0.532, and -0.608 for precipitation, and 0.369, 0.419, and -0.276 for clipping mode, respectively. This study demonstrated that variation in precipitationis the key driver of NPP and composition of a L. chinensis steppe under the precipitation range and clipping intensities evaluated. This improved understanding of the effects of precipitation and clipping on NPP and composition will allow for improved, sustainable management of L. chinensis temperate grassland steppes.
Malinova, Vesna; von Eckardstein, Kajetan; Rohde, Veit; Mielke, Dorothee
2015-10-01
The intraoperative microvascular Doppler sonography (iMDS) is a well-established tool in vascular surgery for blood flow velocity (BFV) monitoring, capable of detecting vessel occlusion. However, identification of subtotal vessel compromise is more difficult, since the measured BFV may substantially vary with changing insonation angles and insonated vessel segments. To keep these parameters constant we combined neuronavigation with iMDS (niMDS). The question was if niMDS allows the detection of subtotal vessel compromise in aneurysm surgery. During surgery, the 3-dimensional reconstruction of the CT-angiography, which was obtained routinely prior to surgery, was displayed by the neuronavigational system. Prior to clipping, neuronavigation was used to define target point and trajectory, which, by coupling the neuronavigational pointer with the Doppler probe, correspond to the insonated vessel segment and the insonation angle. After clipping, for each vessel segment, the same trajectory was used for all consecutive measurements. The mean BFVs pre- and post-clipping were documented. We performed 82 BFV-measurements in 39 aneurysm surgeries. Mean deviation between pre- and post-clipping BFV values was 2.12cm/s. There was a significant correlation between the mean BFV values before and after clipping (r=0.45 [95% CI 17-66%]; p=0.002). One patient experienced new neurological deficits due to occlusion of a perforating vessel that was not insonated. The study could not answer the question if niMDS can detect BFV changes after clipping indicating vessel compromise, as no subtotal vessel occlusion occurred in the 39 operations. However, we proofed that niMDS-measured BFVs only varied minimally in uncompromised vessels pre- and post-clipping, suggesting that vessel compromises might be easily detected during aneurysm surgery. Copyright © 2015 Elsevier B.V. All rights reserved.
Clips versus suture technique: is there a difference?
Chughtai, T; Chen, L Q; Salasidis, G; Nguyen, D; Tchervenkov, C; Morin, J F
2000-11-01
Coronary artery bypass grafting (CABG) is one of the most common procedures performed today, and wound complications are a major source of morbidity and cost. To determine whether there is any difference in wound outcome (including cost in a Canadian context) between a subcuticular suture technique and skin stapling technique for closure of sternal and leg incisions in CABG patients. One hundred and sixty-two patients undergoing CABG were prospectively, randomly placed to have their sternal and leg incisions closed with either a subcuticular suture technique or with a skin clip. Data were obtained through chart review, in-hospital assessments and follow-up visits. Nonblinded assessments were made regarding wound leakage, inflammation, infection, necrosis, swelling, dehiscence and cosmesis. Each of the parameters was graded on a scale from 1 to 4. The cost was evaluated in Canadian dollars. There were trends toward increased rates of in-hospital sternal (P=0.09) and leg (P=0.17) incision inflammation when the wounds were closed with skin clips. There was a significantly greater (P=0.05) rate of sternal wound infection with clips, as well as a tendency (P=0.15) toward a greater rate of mediastinitis at follow-up assessment. Cosmetic outcome was similar for both groups. The cost incurred was significantly greater when skin clips were used for closure. There was a greater than threefold difference, which translates to a greater than $10,000 difference over one year. Closure with a subcuticular technique achieves better outcomes than the use of skin clips. When factoring in the increased cost incurred by using clips, as well as other intangible factors such as surgical skill acquisition, subcuticular suture closure appears to be a favourable method of wound closure in CABG patients compared with the use of skin stapling techniques.
Guo, Bing; Li, Jianbin; Wang, Wei; Li, Fengxiang; Guo, Yanluan; Li, Yankang; Liu, Tonghai
2015-01-01
This study sought to evaluate the dosimetric impact of tumor bed delineation variability (based on clips, seroma or both clips and seroma) during external-beam partial breast irradiation (EB-PBI) planned utilizing four-dimensional computed tomography (4DCT) scans. 4DCT scans of 20 patients with a seroma clarity score (SCS) 3~5 and ≥5 surgical clips were included in this study. The combined volume of the tumor bed formed using clips, seroma, or both clips and seroma on the 10 phases of 4DCT was defined as the internal gross target volume (termed IGTVC, IGTVS and IGTVC+S, respectively). A 1.5-cm margin was added by defining the planning target volume (termed PTVC, PTVS and PTVC+S, respectively). Three treatment plans were established using the 4DCT images (termed EB-PBIC, EB-PBIS, EB-PBIC+S, respectively). The results showed that the volume of IGTVC+S was significantly larger than that of IGTVCand IGTVS. Similarly, the volume of PTVC+S was markedly larger than that of PTVC and PTVS. However, the PTV coverage for EB-PBIC+S was similar to that of EB-PBIC and EB-PBIS, and there were no significant differences in the homogeneity index or conformity index between the three treatment plans (P=0.878, 0.086). The EB-PBIS plan resulted in the lowest ipsilateral normal breast and ipsilateral lung doses compared with the EB-PBIC and EB-PBIC+S plans. To conclude, the volume variability delineated based on clips, seroma or both clips and seroma resulted in dosimetric variability for organs at risk, but did not show a marked influence on the dosimetric distribution.
Guo, Bing; Li, Jianbin; Wang, Wei; Li, Fengxiang; Guo, Yanluan; Li, Yankang; Liu, Tonghai
2015-01-01
This study sought to evaluate the dosimetric impact of tumor bed delineation variability (based on clips, seroma or both clips and seroma) during external-beam partial breast irradiation (EB-PBI) planned utilizing four-dimensional computed tomography (4DCT) scans. 4DCT scans of 20 patients with a seroma clarity score (SCS) 3~5 and ≥5 surgical clips were included in this study. The combined volume of the tumor bed formed using clips, seroma, or both clips and seroma on the 10 phases of 4DCT was defined as the internal gross target volume (termed IGTVC, IGTVS and IGTVC+S, respectively). A 1.5-cm margin was added by defining the planning target volume (termed PTVC, PTVS and PTVC+S, respectively). Three treatment plans were established using the 4DCT images (termed EB-PBIC, EB-PBIS, EB-PBIC+S, respectively). The results showed that the volume of IGTVC+S was significantly larger than that of IGTVCand IGTVS. Similarly, the volume of PTVC+S was markedly larger than that of PTVC and PTVS. However, the PTV coverage for EB-PBIC+S was similar to that of EB-PBIC and EB-PBIS, and there were no significant differences in the homogeneity index or conformity index between the three treatment plans (P=0.878, 0.086). The EB-PBIS plan resulted in the lowest ipsilateral normal breast and ipsilateral lung doses compared with the EB-PBIC and EB-PBIC+S plans. To conclude, the volume variability delineated based on clips, seroma or both clips and seroma resulted in dosimetric variability for organs at risk, but did not show a marked influence on the dosimetric distribution. PMID:26885108
Wang, Kun; Hannaway, David B.; Li, Xianglin
2017-01-01
Leymus chinensis (Trin.) is the dominant vegetation type in eastern Eurasian temperate grasslands but is decreasing due to the combined pressure of reduced precipitation and overgrazing. This study evaluated the separate and combined effects of precipitation and defoliation on net primary productivity (NPP) and composition of a L. chinensis steppe to promote the sustainable development of temperate grasslands through improved management practices. The effects of three precipitation gradients (precipitation unchanged, reduced by 50%, and increased by 50%) and two clipping intensities (clipping once or twice per year) were examined on NPP and composition of the L. chinensis community using a 7-year in situ controlled trial at the Guyuan State Key Monitoring and Research Station of Grassland Ecosystem in China. The results showed that: (1) a 50% reduction in natural precipitation significantly decreased NPP; a 50% increase in precipitation did not significantly increase NPP, but it decreased the importance value of L. chinensis because more water promoted the growth of competing species. (2) Clipping twice per year increased NPP, but the increase was from the dry matter of other species (DMO) component, and not from the dry matter of L. chinensis. (3) The standardized coefficients of a regression model (β) for DMO, NPP, and the importance value of L. chinensis were 0.685, 0.532, and −0.608 for precipitation, and 0.369, 0.419, and −0.276 for clipping mode, respectively. This study demonstrated that variation in precipitationis the key driver of NPP and composition of a L. chinensis steppe under the precipitation range and clipping intensities evaluated. This improved understanding of the effects of precipitation and clipping on NPP and composition will allow for improved, sustainable management of L. chinensis temperate grassland steppes. PMID:29287115
Alozie, Anthony; Paranskaya, Liliya; Westphal, Bernd; Kaminski, Alexander; Steinhoff, Gustav; Sherif, Mohammad; Ince, Hüseyin; Öner, Alper
2017-12-01
Surgical mitral valve repair is the gold standard for treatment of mitral regurgitation. Recently, the transcatheter treatment of mitral regurgitation with the MitraClip ® device (Abbot Vascular Structural Heart, Menlo Park, CA) has demonstrated promising results in treating patients not amenable for surgical correction of mitral valve regurgitation. Most patients reported in the literature requiring surgical bailout after MitraClip treatment presented with residual or recurrent mitral valve regurgitation. Mitral valve stenosis after MitraClip treatment has been rarely reported. From February 2010 to December 2014, four patients out of 165 patients who underwent MitraClip therapy developed symptomatic mitral valve stenosis (2.4%) and needed surgical correction. Data of the four patients were reviewed retrospectively. Follow-up data were obtained from each patient's general practitioner/cardiologist by phone calls and facsimile and were complete in all patients. All four patients were treated with ≥ 2 MitraClip (MC) devices during their initial presentation. All four patients underwent MV replacement with a tissue valve. The postoperative course was uneventful and there was no 30-day mortality. At 6-month follow-up, all patients were alive and in NYHA class I-III. Placement of multiple clip devices may lead to slightly elevated transmitral gradients. This may not necessarily interpret into symptomatic mitral stenosis. However, in some cases this is possible. Caution should be exercised at this phase of the learning curve of the percutaneous MC treatment, especially in use of multiple MC devices. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Itabashi, Yuji; Utsunomiya, Hiroto; Kubo, Shunsuke; Mizutani, Yukiko; Mihara, Hirotsugu; Murata, Mitsushige; Siegel, Robert J; Kar, Saibal; Fukuda, Keiichi; Shiota, Takahiro
2018-04-01
Postprocedural mitral stenosis (MS) is a main limitation for MitraClip™ (Abbot Vascular, Inc., Santa Clara, CA, USA) procedure. The purpose of this study was to detect the preprocedural predictors of high transmitral pressure gradient (TMPG) after MitraClip™ implantation, which indicated postprocedural mitral stenosis (MS). We studied 79 patients who were implanted with MitraClip™ in our institute. Before the procedure, mitral valve orifice area (MVOA), and anterior-posterior (AP) and medial-lateral (ML) mitral annular diameters were measured at diastole using three-dimensional (3D) transesophageal echocardiography (TEE) data set. After the procedure, the mean TMPG was assessed using continuous-wave (CW) Doppler by periprocedural TEE. Preprocedural MVOA, and AP and ML diameter of left ventricular (LV) inflow orifices were larger in patients with mean TMPG ≤4mmHg than in patients with TMPG >4mmHg after 1-and 2-clip implantation. The large MVOA and ML diameter of LV inflow orifice strongly correlated with the low TMPG after 1- and 2-clip implantation. As a result of the receiver operating characteristic curve analysis, the preprocedural MVOA predicted the low postprocedural TMPG more accurately than the ML diameter of LV inflow orifice after 1-clip implantation either in the degenerative or functional mitral regurgitation (MR) patients. After 2-clip implantation, however, the preprocedural ML diameter of LV inflow orifice predicted it more accurately than the MVOA in the degenerative and functional MR patients. 3D TEE derived MVOA predicts the postprocedural MS after 1-clip implantation, however, preprocedural ML diameter of LV inflow orifice is more useful to predict after 2-clip implantation. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Krahé, Barbara; Möller, Ingrid; Huesmann, L Rowell; Kirwil, Lucyna; Felber, Juliane; Berger, Anja
2011-04-01
This study examined the links between desensitization to violent media stimuli and habitual media violence exposure as a predictor and aggressive cognitions and behavior as outcome variables. Two weeks after completing measures of habitual media violence exposure, trait aggression, trait arousability, and normative beliefs about aggression, undergraduates (N = 303) saw a violent film clip and a sad or a funny comparison clip. Skin conductance level (SCL) was measured continuously, and ratings of anxious and pleasant arousal were obtained after each clip. Following the clips, participants completed a lexical decision task to measure accessibility of aggressive cognitions and a competitive reaction time task to measure aggressive behavior. Habitual media violence exposure correlated negatively with SCL during violent clips and positively with pleasant arousal, response times for aggressive words, and trait aggression, but it was unrelated to anxious arousal and aggressive responding during the reaction time task. In path analyses controlling for trait aggression, normative beliefs, and trait arousability, habitual media violence exposure predicted faster accessibility of aggressive cognitions, partly mediated by higher pleasant arousal. Unprovoked aggression during the reaction time task was predicted by lower anxious arousal. Neither habitual media violence usage nor anxious or pleasant arousal predicted provoked aggression during the laboratory task, and SCL was unrelated to aggressive cognitions and behavior. No relations were found between habitual media violence viewing and arousal in response to the sad and funny film clips, and arousal in response to the sad and funny clips did not predict aggressive cognitions or aggressive behavior on the laboratory task. This suggests that the observed desensitization effects are specific to violent content.
Krahé, Barbara; Möller, Ingrid; Huesmann, L. Rowell; Kirwil, Lucyna; Felber, Juliane; Berger, Anja
2015-01-01
This study examined the links between desensitization to violent media stimuli and habitual media violence exposure as a predictor and aggressive cognitions and behavior as outcome variables. Two weeks after completing measures of habitual media violence exposure, trait aggression, trait arousability, and normative beliefs about aggression, undergraduates (N = 303) saw a violent film clip and a sad or a funny comparison clip. Skin conductance level (SCL) was measured continuously, and ratings of anxious and pleasant arousal were obtained after each clip. Following the clips, participants completed a lexical decision task to measure accessibility of aggressive cognitions and a competitive reaction time task to measure aggressive behavior. Habitual media violence exposure correlated negatively with SCL during violent clips and positively with pleasant arousal, response times for aggressive words, and trait aggression, but it was unrelated to anxious arousal and aggressive responding during the reaction time task. In path analyses controlling for trait aggression, normative beliefs, and trait arousability, habitual media violence exposure predicted faster accessibility of aggressive cognitions, partly mediated by higher pleasant arousal. Unprovoked aggression during the reaction time task was predicted by lower anxious arousal. Neither habitual media violence usage nor anxious or pleasant arousal predicted provoked aggression during the laboratory task, and SCL was unrelated to aggressive cognitions and behavior. No relations were found between habitual media violence viewing and arousal in response to the sad and funny film clips, and arousal in response to the sad and funny clips did not predict aggressive cognitions or aggressive behavior on the laboratory task. This suggests that the observed desensitization effects are specific to violent content. PMID:21186935
Child, Nicholas; Hanson, Ben; Bishop, Martin; Rinaldi, Christopher A; Bostock, Julian; Western, David; Cooklin, Michael; O'Neil, Mark; Wright, Matthew; Razavi, Reza; Gill, Jaswinder; Taggart, Peter
2014-06-01
Mental stress and emotion have long been associated with ventricular arrhythmias and sudden death in animal models and humans. The effect of mental challenge on ventricular action potential duration (APD) in conscious healthy humans has not been reported. Activation recovery intervals measured from unipolar electrograms as a surrogate for APD (n=19) were recorded from right and left ventricular endocardium during steady-state pacing, whilst subjects watched an emotionally charged film clip. To assess the possible modulating role of altered respiration on APD, the subjects then repeated the same breathing pattern they had during the stress, but without the movie clip. Hemodynamic parameters (mean, systolic, and diastolic blood pressure, and rate of pressure increase) and respiration rate increased during the stressful part of the film clip (P=0.001). APD decreased during the stressful parts of the film clip, for example, for global right ventricular activation recovery interval at end of film clip 193.8 ms (SD, 14) versus 198.0 ms (SD, 13) during the matched breathing control (end film left ventricle 199.8 ms [SD, 16] versus control 201.6 ms [SD, 15]; P=0.004). Respiration rate increased during the stressful part of the film clip (by 2 breaths per minute) and was well matched in the respective control period without any hemodynamic or activation recovery interval changes. Our results document for the first time direct recordings of the effect of a mental challenge protocol on ventricular APD in conscious humans. The effect of mental challenge on APD was not secondary to emotionally induced altered respiration or heart rate. © 2014 American Heart Association, Inc.
Cook, Christian J; Crewther, Blair T
2012-01-01
Previous studies have shown that visual images can produce rapid changes in testosterone concentrations. We explored the acute effects of video clips on salivary testosterone and cortisol concentrations and subsequent voluntary squat performance in highly trained male athletes (n=12). Saliva samples were collected on 6 occasions immediately before and 15 min after watching a brief video clip (approximately 4 min in duration) on a computer screen. The watching of a sad, erotic, aggressive, training motivational, humorous or a neutral control clip was randomised. Subjects then performed a squat workout aimed at producing a 3 repetition maximum (3RM) lift. Significant (P<0.001) relative (%) increases in testosterone concentrations were noted with watching the erotic, humorous, aggressive and training videos (versus control and sad), with testosterone decreasing significantly (versus control) after the sad clip. The aggressive video also produced an elevated cortisol response (% change) and more so than the control and humorous videos (P<0.001). A significant (P<0.003) improvement in 3RM performance was noted after the erotic, aggressive and training clips (versus control). A strong within-individual correlation (mean r=0.85) was also noted between the relative changes in testosterone and the 3RM squats across all video sessions (P<0.001). In conclusion, different video clips were associated with different changes in salivary free hormone concentrations and the relative changes in testosterone closely mapped 3RM squat performance in a group of highly trained males. Thus, speculatively, using short video presentations in the pre-workout environment offers an opportunity for understanding the outcomes of hormonal change, athlete behaviour and subsequent voluntary performance. Copyright © 2011 Elsevier Inc. All rights reserved.
Pfleeger, Adam Z.; Eagles-Smith, Collin A.; Kowalski, Brandon M.; Herring, Garth; Willacker, James J.; Jackson, Allyson K.; Pierce, John
2016-01-01
Exposure to environmental contaminants has been implicated as a factor in global amphibian decline. Mercury (Hg) is a particularly widespread contaminant that biomagnifies in amphibians and can cause a suite of deleterious effects. However, monitoring contaminant exposure in amphibian tissues may conflict with conservation goals if lethal take is required. Thus, there is a need to develop non-lethal tissue sampling techniques to quantify contaminant exposure in amphibians. Some minimally invasive sampling techniques, such as toe-clipping, are common in population-genetic research, but it is unclear if these methods can adequately characterize contaminant exposure. We examined the relationships between mercury (Hg) concentrations in non-lethally sampled tissues and paired whole-bodies in five amphibian species. Specifically, we examined the utility of three different tail-clip sections from four salamander species and toe-clips from one anuran species. Both tail and toe-clips accurately predicted whole-body THg concentrations, but the relationships differed among species and the specific tail-clip section or toe that was used. Tail-clips comprised of the distal 0–2 cm segment performed the best across all salamander species, explaining between 82 and 92 % of the variation in paired whole-body THg concentrations. Toe-clips were less effective predictors of frog THg concentrations, but THg concentrations in outer rear toes accounted for up to 79 % of the variability in frog whole-body THg concentrations. These findings suggest non-lethal sampling of tails and toes has potential applications for monitoring contaminant exposure and risk in amphibians, but care must be taken to ensure consistent collection and interpretation of samples.
Cerebral Protection During MitraClip Implantation: Initial Experience at 2 Centers.
Frerker, Christian; Schlüter, Michael; Sanchez, Oscar D; Reith, Sebastian; Romero, Maria E; Ladich, Elena; Schröder, Jörg; Schmidt, Tobias; Kreidel, Felix; Joner, Michael; Virmani, Renu; Kuck, Karl-Heinz
2016-01-25
This study sought to assess the feasibility and safety of using a filter-based cerebral protection system (CPS) during MitraClip implantation and to report on the histopathologic analysis of the captured debris. Stroke is one of the serious adverse events associated with MitraClip therapy. Between July 2014 and March 2015, 14 surgical high-risk patients (age 75 ± 7 years; 7 men; median logistic EuroSCORE 21%) underwent MitraClip implantation employing cerebral protection with a dual embolic filter system. All patients had severe mitral regurgitation of predominantly functional origin. All procedures were successfully completed for both CPS deployment/retrieval and MitraClip implantation. A total of 28 filters (2 from each patient) were analyzed. Microscopically, debris was identified in all 14 patients. The most common tissue types were acute thrombus and small fragments of foreign material, which were found in 12 patients (85.7%) each. Organizing thrombus was present in 4 patients (28.6%), valve tissue and/or superficial atrial wall tissue in 9 patients (64.3%), and fragments of myocardium in 2 patients (14.3%). No transient ischemic attacks, strokes, or deaths occurred peri-procedurally or during a median follow-up interval of 8.4 months. In this small study of patients undergoing MitraClip treatment with cerebral protection, embolic debris potentially conducive to cerebrovascular events was found in all patients. Debris was composed most often of acute thrombus, foreign material likely originating from the hydrophilic device coating, and valve/atrial wall tissue. Further studies are warranted to assess the impact of cerebral protection on the incidence of cerebrovascular events after MitraClip therapy. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Jia, Xiaohong; Zhou, Xuhui; Luo, Yiqi; Xue, Kai; Xue, Xian; Xu, Xia; Yang, Yuanhe; Wu, Liyou; Zhou, Jizhong
2014-01-01
Regulatory mechanisms of soil respiratory carbon (C) release induced by substrates (i.e., plant derived substrates) are critical for predicting ecosystem responses to climate change, but the mechanisms are not well understood. In this study, we sampled soils from a long-term field manipulative experiment and conducted a laboratory incubation to explore the role of substrate supply in regulating the differences in soil C release among the experimental treatments, including control, warming, clipping, and warming plus clipping. Three types of substrates (glucose, C3 and C4 plant materials) were added with an amount equal to 1% of soil dry weight under the four treatments. We found that the addition of all three substrates significantly stimulated soil respiratory C release in all four warming and clipping treatments. In soils without substrate addition, warming significantly stimulated soil C release but clipping decreased it. However, additions of glucose and C3 plant materials (C3 addition) offset the warming effects, whereas C4 addition still showed the warming-induced stimulation of soil C release. Our results suggest that long-term warming may inhibit microbial capacity for decomposition of C3 litter but may enhance it for decomposition of C4 litter. Such warming-induced adaptation of microbial communities may weaken the positive C-cycle feedback to warming due to increased proportion of C4 species in plant community and decreased litter quality. In contrast, clipping may weaken microbial capacity for warming-induced decomposition of C4 litter but may enhance it for C3 litter. Warming- and clipping-induced shifts in microbial metabolic capacity may be strongly associated with changes in plant species composition and could substantially influence soil C dynamics in response to global change. PMID:25490701
Jia, Xiaohong; Zhou, Xuhui; Luo, Yiqi; Xue, Kai; Xue, Xian; Xu, Xia; Yang, Yuanhe; Wu, Liyou; Zhou, Jizhong
2014-01-01
Regulatory mechanisms of soil respiratory carbon (C) release induced by substrates (i.e., plant derived substrates) are critical for predicting ecosystem responses to climate change, but the mechanisms are not well understood. In this study, we sampled soils from a long-term field manipulative experiment and conducted a laboratory incubation to explore the role of substrate supply in regulating the differences in soil C release among the experimental treatments, including control, warming, clipping, and warming plus clipping. Three types of substrates (glucose, C3 and C4 plant materials) were added with an amount equal to 1% of soil dry weight under the four treatments. We found that the addition of all three substrates significantly stimulated soil respiratory C release in all four warming and clipping treatments. In soils without substrate addition, warming significantly stimulated soil C release but clipping decreased it. However, additions of glucose and C3 plant materials (C3 addition) offset the warming effects, whereas C4 addition still showed the warming-induced stimulation of soil C release. Our results suggest that long-term warming may inhibit microbial capacity for decomposition of C3 litter but may enhance it for decomposition of C4 litter. Such warming-induced adaptation of microbial communities may weaken the positive C-cycle feedback to warming due to increased proportion of C4 species in plant community and decreased litter quality. In contrast, clipping may weaken microbial capacity for warming-induced decomposition of C4 litter but may enhance it for C3 litter. Warming- and clipping-induced shifts in microbial metabolic capacity may be strongly associated with changes in plant species composition and could substantially influence soil C dynamics in response to global change.
Child, Nicholas; Hanson, Ben; Bishop, Martin; Rinaldi, Christopher A; Bostock, Julian; Western, David; Cooklin, Michael; O’Neil, Mark; Wright, Matthew; Razavi, Reza; Gill, Jaswinder; Taggart, Peter
2014-01-01
Background Mental stress and emotion have long been associated with ventricular arrhythmias and sudden death in animal models and humans. The effect of mental challenge on ventricular action potential duration (APD) in conscious healthy humans has not been reported. Methods and Results Activation recovery intervals (ARI) measured from unipolar electrograms as a surrogate for APD (n=19) were recorded from right and left ventricular endocardium during steady state pacing while subjects watched an emotionally charged film clip. To assess the possible modulating role of altered respiration on APD, the subjects then repeated the same breathing pattern they had during the stress, but without the movie clip. Haemodynamic parameters (mean, systolic, and diastolic blood pressure, and rate of pressure increase) and respiration rate increased during the stressful part of the film clip (p=0.001). APD decreased during the stressful parts of the film clip, eg for global RV ARI at end of film clip 193.8ms (SD 14) vs 198.0ms (SD13) during the matched breathing control (end film LV 199.8ms (SD16) vs control 201.6ms (SD15), p=0.004. Respiration rate increased during the stressful part of the film clip (by 2 breaths/minute), and was well matched in the respective control period without any haemodynamic or ARI changes. Conclusions Our results document for the first time direct recordings of the effect of a mental challenge protocol on ventricular action potential duration in conscious humans. The effect of mental challenge on APD was not secondary to emotionally-induced altered respiration or heart rate. PMID:24833641
Suitable closure for post-duodenal endoscopic resection taking medical costs into consideration.
Mori, Hirohito; Ayaki, Maki; Kobara, Hideki; Fujihara, Shintaro; Nishiyama, Noriko; Matsunaga, Tae; Yachida, Tatsuo; Masaki, Tsutomu
2015-05-07
To compare closure methods, closure times and medical costs between two groups of patients who had post-endoscopic resection (ER) artificial ulcer floor closures. Nineteen patients with duodenal adenoma, early duodenal cancer, and subepithelial tumors that received ER between September 2009 and September 2014 at Kagawa University Hospital and Ehime Rosai Hospital, an affiliated hospital of Kagawa University, were included in the study. We retrospectively compared two groups of patients who received post-ER artificial ulcer floor closure: the conventional clip group vs the over-the-scope clip (OTSC) group. Delayed bleeding, procedure time of closure, delayed perforation, total number of conventional clips and OTSCs and medical costs were analyzed. Although we observed delayed bleeding in three patients in the conventional clip group, we observed no delayed bleeding in the OTSC group (P = 0.049). We did not observe perforation in either group. The mean procedure times for ulcer closure were 33.26 ± 12.57 min and 9.71 ± 2.92 min, respectively (P = 0.0001). The resection diameters were 18.8 ± 1.30 mm and 22.9 ± 1.21 mm for the conventional clip group and the OTSC group, respectively, with significant difference (P = 0.039). As for medical costs, the costs of all conventional clips were USD $1257 and the costs of OTSCs were $7850 (P = 0.005). If the post-ER ulcer is under 20 mm in diameter, a conventional clip closure may be more suitable with regard to the prevention of delayed perforation and to medical costs. If the post-ER ulcer is over 20 mm, the OTSC closure should be selected with regard to safety and reliable closure even if there are high medical costs.
Easy clip to treat anal fistula tracts: a word of caution.
Gautier, M; Godeberge, P; Ganansia, R; Bozio, G; Godart, B; Bigard, M A; Barthet, M; Siproudhis, L
2015-05-01
Closing the internal opening by a clip ovesco has been recently proposed for healing the fistula tract, but, to date, data on benefit are poorly analyzed. The aim was to report a preliminary multicenter experience. Retrospective study was undertaken in six different French centers: surgical procedure, immediate complications, and follow-up have been collected. Nineteen clips were inserted in 17 patients (M/F, 4/13; median age, 42 years [29-54]) who had an anal fistula: 12 (71%) high fistulas (including 4 rectovaginal fistulas), 5 (29%) lower fistulas (with 3 rectovaginal fistulas), and 6 (35%) Crohn's fistulas. Out of 17 patients, 15 had a seton drainage beforehand. The procedure was easy in 8 (47%) patients and the median operative time was 27.5 min (20-36.5). Postoperative period was painful for 11 (65%) patients. A clip migration was noted in 11 patients (65%) after a median follow-up of 10 days (5.5-49.8). Eleven patients (65%) who failed had reoperation including 10 new drainages within the first month (0.5-5). After a mean follow-up of 4 months (2-7),, closing the tract was observed in 2 patients (12%) following the first insertion of the clip and in another one after a second insertion. Treatment of anal fistula by placing a clip on the internal opening is disappointing and deleterious for some patients. A better assessment before dissemination is recommended.
Arfeller, Carola; Schwarzbach, Jens; Ubaldi, Silvia; Ferrari, Paolo; Barchiesi, Guido; Cattaneo, Luigi
2013-04-01
The posterior superior temporal sulcus (pSTS) is active when observing biological motion. We investigated the functional connections of the pSTS node within the action observation network by measuring the after-effect of focal repetitive transcranial magnetic stimulation (rTMS) with whole-brain functional magnetic resonance imaging (fMRI). Participants received 1-Hz rTMS over the pSTS region for 10 min and underwent fMRI immediately after. While scanned, they were shown short video clips of a hand grasping an object (grasp clips) or moving next to it (control clips). rTMS-fMRI was repeated for four consecutive blocks. In two blocks we stimulated the left pSTS region and in the other two the right pSTS region. For each side TMS was applied with an effective intensity (95 % of motor threshold) or with ineffective intensity (50 % of motor threshold). Brain regions showing interactive effects of (clip type) × (TMS intensity) were identified in the lateral temporo-occipital cortex, in the anterior intraparietal region and in the ventral premotor cortex. Remote effects of rTMS were mostly limited to the stimulated hemisphere and consisted in an increase of blood oxygen level-dependent responses to grasp clips compared to control clips. We show that the pSTS occupies a pivotal relay position during observation of goal-directed actions.
Harmonic Scalpel versus electrocautery and surgical clips in head and neck free-flap harvesting.
Dean, Nichole R; Rosenthal, Eben L; Morgan, Bruce A; Magnuson, J Scott; Carroll, William R
2014-06-01
We sought to determine the safety and utility of Harmonic Scalpel-assisted free-flap harvesting as an alternative to a combined electrocautery and surgical clip technique. The medical records of 103 patients undergoing radial forearm free-flap reconstruction (105 free flaps) for head and neck surgical defects between 2006 and 2008 were reviewed. The use of bipolar electrocautery and surgical clips for division of small perforating vessels (n = 53) was compared to ultrasonic energy (Harmonic Scalpel; Ethicon Endo-Surgery, Inc., Cincinnati, Ohio) (n = 52) free-tissue harvesting techniques. Flap-harvesting time was reduced with the use of the Harmonic Scalpel when compared with electrocautery and surgical clip harvest (31.4 vs. 36.9 minutes, respectively; p = 0.06). Two patients who underwent flap harvest with electrocautery and surgical clips developed postoperative donor site hematomas, whereas no donor site complications were noted in the Harmonic Scalpel group. Recipient site complication rates for infection, fistula, and hematoma were similar for both harvesting techniques (p = 0.77). Two flap failures occurred in the clip-assisted radial forearm free-flap harvest group, and none in the Harmonic Scalpel group. Median length of hospitalization was significantly reduced for patients who underwent free-flap harvest with the Harmonic Scalpel when compared with the other technique (7 vs. 8 days; p = 0.01). The Harmonic Scalpel is safe, and its use is feasible for radial forearm free-flap harvest.
Pregnancy after tubal sterilization with silicone rubber band and spring clip application.
Peterson, H B; Xia, Z; Wilcox, L S; Tylor, L R; Trussell, J
2001-02-01
To determine risk factors for pregnancy after tubal sterilization with silicone rubber bands or spring clips. A total of 3329 women sterilized using silicone rubber bands and 1595 women sterilized using spring clips were followed for up to 14 years as part of a prospective cohort study conducted in medical centers in nine US cities. We assessed the risk of pregnancy by cumulative life-table probabilities and proportional hazards analysis. The risk of pregnancy for women who had silicone rubber band application differed by location of band application and study site. The 10-year cumulative probabilities of pregnancy varied from a low of 0.0 per 1000 procedures at one study site to a high of 42.5 per 1000 procedures in the four combined sites in which fewer than 100 procedures per site were performed. The risk of pregnancy for women who had spring clip application varied by location of clip application, study site, race or ethnicity, tubal disease, and history of abdominal or pelvic surgery. The probabilities across study sites ranged from 7.1 per 1000 procedures at 10 years to 78.0 per 1000 procedures at 5 years (follow-up was limited to 5 years at that site). The 10-year cumulative probability of pregnancy after silicone rubber band and spring clip application is low but varies substantially by both clinical and demographic characteristics.
21 CFR 884.1640 - Culdoscope and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... the female genital organs. This generic type of device may include trocar and cannula, instruments... instruments include: lens cleaning brush, biopsy brush, clip applier (without clips), applicator, cannula...
21 CFR 884.1640 - Culdoscope and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the female genital organs. This generic type of device may include trocar and cannula, instruments... instruments include: lens cleaning brush, biopsy brush, clip applier (without clips), applicator, cannula...
Minimally Invasive Repair of a Prostatorectal Fistula with an Over-the-Scope Rectal Clip
Schmidt-Heikenfeld, Ekkehard; Degener, Stephan; Roosen, Alexander; Boy, Anselm
2017-01-01
Abstract Background: Fistulae between the prostatic urethra and the rectum are rare. They may result from prostatic or rectal surgery. Predisposing factors are previous radiation or immunosuppression. The repair of such fistulae usually involves major surgery. Recently, clips that can be deployed over an endoscope have been developed to close gastrointestinal fistulae or access points for natural orifice surgery. We report the first case of effective treatment of a prostatorectal fistula with a rectal “over-the-scope” clip. Case Presentation: A 64-year-old man under chronic immunosuppression presented with an iatrogenic fistula between the prostatic urethra and the rectum after transurethral resection of the prostate. A transverse colostomy was placed but the fistula failed to heal conservatively. The fistula was effectively closed with an endorectal clip. Six weeks after the procedure, spontaneous micturition was started. Two weeks further, the colostomy was reversed. At 32 months of follow-up, the remains closed, micturition is unimpaired. Conclusion: In select cases of prostatorectal fistula, an endorectal clip may be effectively used for closure. PMID:29098198
Using CLIPS in the domain of knowledge-based massively parallel programming
NASA Technical Reports Server (NTRS)
Dvorak, Jiri J.
1994-01-01
The Program Development Environment (PDE) is a tool for massively parallel programming of distributed-memory architectures. Adopting a knowledge-based approach, the PDE eliminates the complexity introduced by parallel hardware with distributed memory and offers complete transparency in respect of parallelism exploitation. The knowledge-based part of the PDE is realized in CLIPS. Its principal task is to find an efficient parallel realization of the application specified by the user in a comfortable, abstract, domain-oriented formalism. A large collection of fine-grain parallel algorithmic skeletons, represented as COOL objects in a tree hierarchy, contains the algorithmic knowledge. A hybrid knowledge base with rule modules and procedural parts, encoding expertise about application domain, parallel programming, software engineering, and parallel hardware, enables a high degree of automation in the software development process. In this paper, important aspects of the implementation of the PDE using CLIPS and COOL are shown, including the embedding of CLIPS with C++-based parts of the PDE. The appropriateness of the chosen approach and of the CLIPS language for knowledge-based software engineering are discussed.
Murai, Yasuo; Adachi, Koji; Takagi, Ryo; Koketsu, Kenta; Matano, Fumihiro; Teramoto, Akira
2011-11-01
The aim of the present study was to assess a new technique of surgical microscope-based indocyanine green (ICG) videoangiography (VAG) to confirm the patency of the anterior communicating artery (AcomA) after clipping AcomA aneurysms. Aneurysmal clipping of five cases of unruptured, broad-neck AcomA aneurysm was performed using the Carl Zeiss Surgical Microscope OPMI Pentero INFRARED 800. In all five patients, after clipping AcomA aneurysms, the patency of AcomA was confirmed using ICGVAG findings and temporary unilateral occlusion of the A1 segment of the anterior cerebral artery using temporary clips. Images were excellent and enabled a real-time surgical assessment because the structures of interest, including vessels, perforating arteries, or residual aneurysm neck, were visible to the surgeon's eye under the microscope in all five patients. ICGVAG and temporary unilateral occlusion with clips provides a simple, reliable, real-time, and rapid intraoperative assessment of the patency of AcomA. This technique may help to improve the quality of neurosurgical procedures. Copyright © 2011 Elsevier Inc. All rights reserved.
Physiological remodeling of bifurcation aneurysms: preclinical results of the eCLIPs device.
Marotta, Thomas R; Riina, Howard A; McDougall, Ian; Ricci, Donald R; Killer-Oberpfalzer, Monika
2018-02-01
OBJECTIVE Intracranial bifurcation aneurysms are complex lesions for which current therapy, including simple coiling, balloon- or stent-assisted coiling, coil retention, or intrasaccular devices, is inadequate. Thromboembolic complications due to a large burden of intraluminal metal, impedance of access to side branches, and a high recurrence rate, due largely to the unmitigated high-pressure flow into the aneurysm (water hammer effect), are among the limitations imposed by current therapy. The authors describe herein a novel device, eCLIPs, and its use in a preclinical laboratory study that suggests the device's design and functional features may overcome many of these limitations. METHODS A preclinical model of wide-necked bifurcation aneurysms in rabbits was used to assess functional features and efficacy of aneurysm occlusion by the eCLIPs device. RESULTS The eCLIPs device, in bridging the aneurysm neck, allows coil retention, disrupts flow away from the aneurysm, leaves the main vessel and side branches unencumbered by intraluminal metal, and serves as a platform for endothelial growth across the neck, excluding the aneurysm from the circulation. CONCLUSIONS The eCLIPs device permits physiological remodeling of the bifurcation.
The computational structural mechanics testbed architecture. Volume 2: The interface
NASA Technical Reports Server (NTRS)
Felippa, Carlos A.
1988-01-01
This is the third set of five volumes which describe the software architecture for the Computational Structural Mechanics Testbed. Derived from NICE, an integrated software system developed at Lockheed Palo Alto Research Laboratory, the architecture is composed of the command language CLAMP, the command language interpreter CLIP, and the data manager GAL. Volumes 1, 2, and 3 (NASA CR's 178384, 178385, and 178386, respectively) describe CLAMP and CLIP and the CLIP-processor interface. Volumes 4 and 5 (NASA CR's 178387 and 178388, respectively) describe GAL and its low-level I/O. CLAMP, an acronym for Command Language for Applied Mechanics Processors, is designed to control the flow of execution of processors written for NICE. Volume 3 describes the CLIP-Processor interface and related topics. It is intended only for processor developers.
Adaptive quantization-parameter clip scheme for smooth quality in H.264/AVC.
Hu, Sudeng; Wang, Hanli; Kwong, Sam
2012-04-01
In this paper, we investigate the issues over the smooth quality and the smooth bit rate during rate control (RC) in H.264/AVC. An adaptive quantization-parameter (Q(p)) clip scheme is proposed to optimize the quality smoothness while keeping the bit-rate fluctuation at an acceptable level. First, the frame complexity variation is studied by defining a complexity ratio between two nearby frames. Second, the range of the generated bits is analyzed to prevent the encoder buffer from overflow and underflow. Third, based on the safe range of the generated bits, an optimal Q(p) clip range is developed to reduce the quality fluctuation. Experimental results demonstrate that the proposed Q(p) clip scheme can achieve excellent performance in quality smoothness and buffer regulation.
Alexander, D.J.
1994-01-04
An attachment for placement between a test specimen and a remote clip gage extensometer providing improved fracture toughness tests of materials at elevated temperature is described. Using a cylindrical tube and axial rod in new relationship, the device transfers the displacement signal of the fracture toughness test specimen directly to a clip gage extensometer located outside the high temperature furnace. Virtually frictionless operation is assured by having the test specimen center one end of the rod in one end of the tube, while the clip gage extensometer arms center the other end of the rod in the other end of the tube. By providing positive control over both ends of both rod and tube, the attachment may be operated in orientations other than vertical. 1 figure.
The computational structural mechanics testbed architecture. Volume 2: Directives
NASA Technical Reports Server (NTRS)
Felippa, Carlos A.
1989-01-01
This is the second of a set of five volumes which describe the software architecture for the Computational Structural Mechanics Testbed. Derived from NICE, an integrated software system developed at Lockheed Palo Alto Research Laboratory, the architecture is composed of the command language (CLAMP), the command language interpreter (CLIP), and the data manager (GAL). Volumes 1, 2, and 3 (NASA CR's 178384, 178385, and 178386, respectively) describe CLAMP and CLIP and the CLIP-processor interface. Volumes 4 and 5 (NASA CR's 178387 and 178388, respectively) describe GAL and its low-level I/O. CLAMP, an acronym for Command Language for Applied Mechanics Processors, is designed to control the flow of execution of processors written for NICE. Volume 2 describes the CLIP directives in detail. It is intended for intermediate and advanced users.
Clipping and shading alter NH4+ uptake by plants in grazed and ungrazed Tibetan alpine grasslands
NASA Astrophysics Data System (ADS)
Sun, Yue; Schleuss, Per; Li, Qianru; Yang, Baijie; Xu, Xingliang; Kuzyakov, Yakov
2014-05-01
The Kobresia pastures are the most common and most important vegetation type on the Tibetan Plateau as it occupies more than 35% the plateau area. These pastures have been remained stable for about one million years, but have been strongly changed by increased grazing in the recent decades which led to serious grassland degradation. Previous studies on the N cycling in alpine grasslands showed that plant growth was limited by low N availability due to low N mineralization caused by low temperature. However, the effect of grazing on N turnover processes and plant N uptake remains unclear. To clarify the grazing effect for a better understanding N mineralization and plant N uptake in these alpine grasslands, we conducted a 15N experiment in grazed and ungraded plots in these alpine grasslands. Because ammonium was a dominant N form, we used 15N-labeled ammonium so that we can also measure gross N mineralization. To explore the effect of root exudates on 15NH4+ uptake by plants and gross N mineralization, three treatments such as clipping, shading and control were used. Initially, all treatments were labeled by 15NH4+, with blank treatments no 15N tracer addition. Plant and soil samples were collected 7, 14 and 28 days after the labelling. 15NH4+ uptake by alpine plants almost did not change after clipping in the grazed plots, but its uptake was lower under the clipping treatment than under the control treatment in the ungrazed plots. 15N recovery in plants under the shading treatment remained the lowest level in grazed and ungrazed plots. Although clipping removed a part of aboveground biomass, subsequent stimulation of plant growth increased N uptake by plants. Likely, moderate grazing removed a part of aboveground biomass, but 15N recovery in plants was still compared to that in the ungrazed plots, indicating moderate grazing stimulate N uptake by plants through compensatory growth. Gross N mineralization under the shading treatment was higher than under the clipping treatment (shading vs clipping: 0.42 vs 0.34 mg N kg-1 h-1) in the grazed plot. In contrast, gross N mineralization was lower for shading treatment than for clipping treatment (shading vs clipping 0.47 vs 0.63 mg N kg-1 h-1) in the ungrazed plot. Gross N mineralization in the ungrazed soil was higher than in the grazed soil, suggesting that grazing greatly reduced the potential to provide available nitrogen for plants and microorganisms. Therefore, we concluded that low photosynthesis caused by shading, clipping and grazing can affect N transformation and therefore affect the format of soil organic matter.
... follow these steps: Remove the clear plastic dust cap and the safety clip from the nasal spray ... the other nostril. Replace the clear plastic dust cap and safety clip. If the nasal tip becomes ...
21 CFR 884.1720 - Gynecologic laparoscope and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... genital organs. This generic type of device may include: Trocar and cannula, instruments used through an... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...
21 CFR 884.1720 - Gynecologic laparoscope and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... genital organs. This generic type of device may include: Trocar and cannula, instruments used through an... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...
Evaluation of Veriox as a Skin Decontamination Product after Dermal Exposure to the Nerve Agent VX
2016-09-01
in hair -clipped, unanesthetized guinea pigs. Efficacy was established by generating VX dose-lethality curves for each DC product based on 24 survival...This study compared the effectiveness of Veriox® to RSDL when each was used as a DC product 2 min after dermal exposure to VX in hair -clipped...by the dermal LD90 of VX in untreated animals. A LD90 value of 188 μg/kg generated in hair -clipped, unanesthetized guinea pigs (Clarkson, personal
[Choledochal lithiasis and stenosis secondary to the migration of a surgical clip].
Baldomà España, M; Pernas Canadell, J C; González Ceballos, S
2014-01-01
The migration of a clip to the common bile duct after cholecystectomy is an uncommon, usually late, complication that can lead to diverse complications like stone formation, stenosis, and obstruction in the bile duct. We present the case of a patient who presented with signs and symptoms of cholangitis due to clip migration one year after laparoscopic cholecystectomy; endoscopic retrograde cholangiopancreatography and biliary tract stent placement resolved the problem. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
2014-04-15
the floor on which the platform is dropped upon. Alternatively, a base excitation can be provided to the sliding platform in the upward vertical...7ms clips of chest resultant acceleration, (7) 7ms clip of pelvic vertical acceleration, (8,9) Peak and 30ms clips of lumbar spine compression, and...10) Pelvic vertical Dynamic Response Index (DRI)[12]. The sample size for each of the three seating variants consisted of 230 MADYMO
Second CLIPS Conference Proceedings, volume 2
NASA Technical Reports Server (NTRS)
Giarratano, Joseph (Editor); Culbert, Christopher J. (Editor)
1991-01-01
Papers presented at the 2nd C Language Integrated Production System (CLIPS) Conference held at the Lyndon B. Johnson Space Center (JSC) on 23-25 September 1991 are documented in these proceedings. CLIPS is an expert system tool developed by the Software Technology Branch at NASA JSC and is used at over 4000 sites by government, industry, and business. During the three days of the conference, over 40 papers were presented by experts from NASA, Department of Defense, other government agencies, universities, and industry.
Next-Generation Image and Sound Processing Strategies: Exploiting the Biological Model
2007-05-01
several video game clips which were recorded while observers interactively played the games. The feature vectors may be derived from either: the...phase, we use a different video game clip to test the model. Frames from the test clip are passed in parallel to a bottom-up saliency model, as well as... video games (Figure 6). We found that the TD model alone predicts where humans look about twice as well as does the BU model alone; in addition, a
40 CFR 60.1440 - What is yard waste?
Code of Federal Regulations, 2010 CFR
2010-07-01
....1440 What is yard waste? Yard waste is grass, grass clippings, bushes, shrubs, and clippings from bushes and shrubs. They come from residential, commercial/retail, institutional, or industrial sources as...
Serine protease-related proteins in the malaria mosquito, Anopheles gambiae.
Cao, Xiaolong; Gulati, Mansi; Jiang, Haobo
2017-09-01
Insect serine proteases (SPs) and serine protease homologs (SPHs) participate in digestion, defense, development, and other physiological processes. In mosquitoes, some clip-domain SPs and SPHs (i.e. CLIPs) have been investigated for possible roles in antiparasitic responses. In a recent test aimed at improving quality of gene models in the Anopheles gambiae genome using RNA-seq data, we observed various discrepancies between gene models in AgamP4.5 and corresponding sequences selected from those modeled by Cufflinks, Trinity and Bridger. Here we report a comparative analysis of the 337 SP-related proteins in A. gambiae by examining their domain structures, sequence diversity, chromosomal locations, and expression patterns. One hundred and ten CLIPs contain 1 to 5 clip domains in addition to their protease domains (PDs) or non-catalytic, protease-like domains (PLDs). They are divided into five subgroups: CLIPAs (22) are clip 1-5 -PLD; CLIPBs (29), CLIPCs (12) and CLIPDs (14) are mainly clip-PD; most CLIPEs (33) have a domain structure of PD/PLD-PLD-clip-PLD 0-1 . While expression of the CLIP genes in group-1 is generally low and detected in various tissue- and stage-specific RNA-seq libraries, some putative GPs/GPHs (i.e. single domain gut SPs/SPHs) in group-2 are highly expressed in midgut, whole larva or whole adult libraries. In comparison, 46 SPs, 26 SPHs, and 37 multi-domain SPs/SPHs (i.e. PD/PLD-PLD ≥1 ) in group-3 do not seem to be specifically expressed in digestive tract. There are 16 SPs and 2 SPH containing other types of putative regulatory domains (e.g. LDLa, CUB, Gd). Of the 337 SP and SPH genes, 159 were sorted into 46 groups (2-8 members/group) based on similar phylogenetic tree position, chromosomal location, and expression profile. This information and analysis, including improved gene models and protein sequences, constitute a solid foundation for functional analysis of the SP-related proteins in A. gambiae. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pearce, Dora C.; Dowling, Kim; Gerson, Andrea R.
2010-05-04
Arsenic is naturally associated with gold mineralization and elevated in some soils and mine waste around historical gold mining activity in Victoria, Australia. To explore uptake, arsenic concentrations in children's toenail clippings and household soils were measured, and the microdistribution and speciation of arsenic in situ in toenail clipping thin sections investigated using synchrotron-based X-ray microprobe techniques. The ability to differentiate exogenous arsenic was explored by investigating surface contamination on cleaned clippings using depth profiling, and direct diffusion of arsenic into incubated clippings. Total arsenic concentrations ranged from 0.15 to 2.1 {micro}g/g (n = 29) in clipping samples and frommore » 3.3 to 130 {micro}g/g (n = 22) in household soils, with significant correlation between transformed arsenic concentrations (Pearson's r = 0.42, P = 0.023) when household soil was treated as independent. In clipping thin sections (n = 2), X-ray fluorescence (XRF) mapping showed discrete layering of arsenic consistent with nail structure, and irregular arsenic incorporation along the nail growth axis. Arsenic concentrations were heterogeneous at 10 x 10 {micro}m microprobe spot locations investigated (< 0.1 to 13.3 {micro}g/g). X-ray absorption near-edge structure (XANES) spectra suggested the presence of two distinct arsenic species: a lower oxidation state species, possibly with mixed sulphur and methyl coordination (denoted As{sub (-S, -ch3)}{sup {approx}III}); and a higher oxidation state species (denoted As{sub (-O)}{sup {approx}V}). Depth profiling suggested that surface contamination was unlikely (n = 4), and XRF and XANES analyses of thin sections of clippings incubated in dry or wet mine waste, or untreated, suggested direct diffusion of arsenic occurred under moist conditions. These findings suggest that arsenic in soil contributes to some systemic absorption associated with periodic exposures among children resident in areas of historic gold mining activity in Victoria, Australia. Future studies are required to ascertain if adverse health effects are associated with current levels of arsenic uptake.« less
NASA Technical Reports Server (NTRS)
1991-01-01
A montage of video clips over the years, footage shows the spacecrews, launch, and landing for different orbiters and missions. Clips include the Endeavour and Atlantis Orbiters and are shown to the music of the American National Anthem.
Photovoltaic module with removable wind deflector
Botkin, Jonathan [El Cerrito, CA; Graves, Simon [Berkeley, CA; Danning, Matt [Oakland, CA; Culligan, Matthew [Berkeley, CA
2012-08-07
A photovoltaic (PV) module assembly including a PV module, a deflector, and a clip. The PV module includes a PV device and a frame. A PV laminate is assembled to the frame, and the frame includes a support arm forming a seat. The deflector defines a front face and a rear face, with the clip extending from either the trailing frame member or the rear face of the deflector. In a mounted state, the deflector is nested within the seat and is releasably mounted to the trailing frame member via the clip. In some embodiments, the support arm forms a second seat, with the PV module assembly providing a second mounted state in which the deflector is in a differing orientation/slope, nested within the second seat and releasably mounted to the trailing frame member via the clip.
Photovoltaic module with removable wind deflector
Botkin, Jonathan; Graves, Simon; Danning, Matt; Culligan, Matthew
2014-02-18
A photovoltaic (PV) module assembly including a PV module, a deflector, and a clip. The PV module includes a PV device and a frame. A PV laminate is assembled to the frame, and the frame includes a support arm forming a seat. The deflector defines a front face and a rear face, with the clip extending from either the trailing frame member or the rear face of the deflector. In a mounted state, the deflector is nested within the seat and is releasably mounted to the trailing frame member via the clip. In some embodiments, the support arm forms a second seat, with the PV module assembly providing a second mounted state in which the deflector is in a differing orientation/slope, nested within the second seat and releasably mounted to the trailing frame member via the clip.
An Efficient Method for Hair Containment During Head and Neck Surgery.
Zingaretti, Nicola; De Biasio, Fabrizio; Riccio, Michele; Marchesi, Andrea; Parodi, Pier Camillo
2017-11-01
The authors present a simple technique for operations around hair-bearing areas such as during a rhytidectomy. Hair surrounding the surgical field is twisted into bundles and clipped with duckbill clips. The authors repeat the procedure for each strand of hair. Between 5 and 7 duckbill clips may be required per surgery.The clippers are faster, easily applicable, and well performing. They can be used with different hair lengths, and they do not require any additional trimming or shaving; clips also keep the hair firmly in place, and they do not loosen up in the process.This technical note explains a very simple, economical, and less time-consuming method to control hair located around the surgical site. It may be applied to all procedures within the field of the hair-bearing scalp, including craniofacial and maxillofacial surgery.
Photovoltaic module with removable wind deflector
Botkin, Jonathan; Graves, Simon; Danning, Matt; Culligan, Matthew
2013-05-28
A photovoltaic (PV) module assembly including a PV module, a deflector, and a clip. The PV module includes a PV device and a frame. A PV laminate is assembled to the frame, and the frame includes a support arm forming a seat. The deflector defines a front face and a rear face, with the clip extending from either the trailing frame member or the rear face of the deflector. In a mounted state, the deflector is nested within the seat and is releasably mounted to the trailing frame member via the clip. In some embodiments, the support arm forms a second seat, with the PV module assembly providing a second mounted state in which the deflector is in a differing orientation/slope, nested within the second seat and releasably mounted to the trailing frame member via the clip.
Third CLIPS Conference Proceedings, volume 1
NASA Technical Reports Server (NTRS)
Riley, Gary (Editor)
1994-01-01
Expert systems are computed programs which emulate human expertise in well defined problem domains. The potential payoff from expert systems is high: valuable expertise can be captured and preserved, repetitive and/or mundane tasks requiring human expertise can be automated, and uniformity can be applied in decision making processes. The C Language Integrated Production Systems (CLIPS) is an expert system building tool, developed at the Johnson Space Center, which provides a complete environment for the development and delivery of rule and/or object based expert systems. CLIPS was specifically designed to provide a low cost option for developing and deploying expert system applications across a wide range of hardware platforms. The development of CLIPS has helped to improve the ability to deliver expert systems technology throughout the public and private sectors for a wide range of applications and diverse computing environments.
Otani, Naoki; Morimoto, Yuji; Fujii, Kazuya; Toyooka, Terushige; Wada, Kojiro; Mori, Kentaro
2017-12-01
Endoscopy can observe the anatomical components in a deeply located and/or hidden area during neurosurgical procedures under the operating microscope. We have newly developed a flexible ultrathin endoscope integrated with irrigation suction apparatus (FUEISA) to visualize deeply located and/or hidden areas for assisting microneurosurgery. The present study investigated the usefulness of the FUEISA system for direct clipping surgery of cerebral aneurysms. Twenty-one patients underwent microneurosurgery assisted with the FUEISA system for direct clipping of cerebral aneurysms. The flexible ultrathin endoscope (outer diameter 0.75mm) consists of an image guide (6000 dpi) and a light guide, integrated with the irrigation suction apparatus. This endoscopic system was inserted before and after clipping to observe the anatomical conditions surrounding the lesions. In all cases, handling and operation of the FUEISA was technically successful during the surgical procedure. The ultrathin endoscope was adequately integrated with the irrigation suction apparatus in all cases. General anatomy visualization including the lenticulostriate arteries, medial striate arteries, and/or internal carotid artery perforators was possible, and the correct clip positioning and vessel conditions were easily checked. The endoscope revealed that the clip had been positioned incorrectly in one case. No complications associated with the endoscopic system occurred. The FUEISA system can be applied with safe manipulation, which was remarkably useful for confirmation of the presence of perforators and cranial nerves behind the lesions, particularly anatomical components located in deep and/or hidden areas during clipping of cerebral aneurysms. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Fenz, Wolfgang; Dirnberger, Johannes
2015-03-01
Providing suitable training for aspiring neurosurgeons is becoming more and more problematic. The increasing popularity of the endovascular treatment of intracranial aneurysms leads to a lack of simple surgical situations for clipping operations, leaving mainly the complex cases, which present even experienced surgeons with a challenge. To alleviate this situation, we have developed a training simulator with haptic interaction allowing trainees to practice virtual clipping surgeries on real patient-specific vessel geometries. By using specialized finite element (FEM) algorithms (fast finite element method, matrix condensation) combined with GPU acceleration, we can achieve the necessary frame rate for smooth real-time interaction with the detailed models needed for a realistic simulation of the vessel wall deformation caused by the clamping with surgical clips. Vessel wall geometries for typical training scenarios were obtained from 3D-reconstructed medical image data, while for the instruments (clipping forceps, various types of clips, suction tubes) we use models provided by manufacturer Aesculap AG. Collisions between vessel and instruments have to be continuously detected and transformed into corresponding boundary conditions and feedback forces, calculated using a contact plane method. After a training, the achieved result can be assessed based on various criteria, including a simulation of the residual blood flow into the aneurysm. Rigid models of the surgical access and surrounding brain tissue, plus coupling a real forceps to the haptic input device further increase the realism of the simulation.
Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F
2017-04-01
The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Subramanian, Ramanathan; Shankar, Divya; Sebe, Nicu; Melcher, David
2014-03-26
A basic question in vision research regards where people look in complex scenes and how this influences their performance in various tasks. Previous studies with static images have demonstrated a close link between where people look and what they remember. Here, we examined the pattern of eye movements when participants watched neutral and emotional clips from Hollywood-style movies. Participants answered multiple-choice memory questions concerning visual and auditory scene details immediately upon viewing 1-min-long neutral or emotional movie clips. Fixations were more narrowly focused for emotional clips, and immediate memory for object details was worse compared to matched neutral scenes, implying preferential attention to emotional events. Although we found the expected correlation between where people looked and what they remembered for neutral clips, this relationship broke down for emotional clips. When participants were subsequently presented with key frames (static images) extracted from the movie clips such that presentation duration of the target objects (TOs) corresponding to the multiple-choice questions was matched and the earlier questions were repeated, more fixations were observed on the TOs, and memory performance also improved significantly, confirming that emotion modulates the relationship between gaze position and memory performance. Finally, in a long-term memory test, old/new recognition performance was significantly better for emotional scenes as compared to neutral scenes. Overall, these results are consistent with the hypothesis that emotional content draws eye fixations and strengthens memory for the scene gist while weakening encoding of peripheral scene details.
Implant retained auricular prosthesis with a modified hader bar: a case report.
Lovely, M; Dathan, Pradeep C; Gopal, Dinesh; George, Biji Thomas; Chandrasekharan Nair, K
2014-06-01
Auricular prostheses for defects of external ear are retained either by mechanical means or implants. All implant retained prostheses are retained by various means such as bar and clip, magnetic attachments or a combination of bar, clip and magnets. The commonest problem encountered with the bar and clip system is loosening of the clip after 3-4 months. When magnets are used as retaining component they tend to corrode over a period of time. So various alternative retention methods which possess good retentive qualities, ease of reparability and patient friendly were tried. In the present case a newly modified Hader bar design which can act as an additional retentive feature apart from the clip is employed to increase retention. The major advantages in the modified Hader bar system were that only two implants were employed, the additional loops in the Hader bar prevented micro movements and the retentive acrylic locks were easy to repair if broken. The modified Hader bar has anti-rotational slots which prevents the sliding or rotation of the prosthesis which gave new confidence to the patient who was otherwise worried of inadvertent displacement of the ear prosthesis while playing.
Trans-Pacific tele-ultrasound image transmission of fetal central nervous system structures.
Ferreira, Adilson Cunha; Araujo Júnior, Edward; Martins, Wellington P; Jordão, João Francisco; Oliani, Antônio Hélio; Meagher, Simon E; Da Silva Costa, Fabricio
2015-01-01
To assess the quality of images and video clips of fetal central nervous (CNS) structures obtained by ultrasound and transmitted via tele-ultrasound from Brazil to Australia. In this cross-sectional study, 15 normal singleton pregnant women between 20 and 26 weeks were selected. Fetal CNS structures were obtained by images and video clips. The exams were transmitted in real-time using a broadband internet and an inexpensive video streaming device. Four blinded examiners evaluated the quality of the exams using the Likert scale. We calculated the mean, standard deviation, mean difference, and p values were obtained from paired t tests. The quality of the original video clips was slightly better than that observed by the transmitted video clips; mean difference considering all observers = 0.23 points. In 47/60 comparisons (78.3%; 95% CI = 66.4-86.9%) the quality of the video clips were judged to be the same. In 182/240 still images (75.8%; 95% CI = 70.0-80.8%) the scores of transmitted image were considered the same as the original. We demonstrated that long distance tele-ultrasound transmission of fetal CNS structures using an inexpensive video streaming device provided images of subjective good quality.
Miyoshi, Hiroyuki; Migita, Keisuke; Kumano, Kiyoshi; Hashimoto, Naomi; Toyota, Akihiro
2016-11-01
We report a case of aphasia after neck clipping of a ruptured aneurysm at the origin of the duplicated middle cerebral artery(DMCA). A 60-year-old woman had a sudden onset of headache and nausea. A computed tomography(CT)scan revealed diffuse subarachnoid hemorrhage. Head three-dimensional CT angiography(3D-CTA)showed a left DMCA with a saccular aneurysm at the origin. She became aphasic on the third day after aneurysmal neck clipping. A CT scan revealed a low-density area in the anterior portion of the left temporal lobe, which is perfused by the DMCA. The DMCA was patent on 3D-CTA, but the angle between the ICA and the DMCA changed steep. It is suspected that the clip changed the branching angle at the DMCA origin, which may have led to decreased blood flow in the DMCA. She received linguistic rehabilitation for dysnomia and was discharged with slight difficulty in naming objects. Six months later, she recovered from the aphasia. One year later, the DMCA was patent on 3D-CTA. We should pay attention to ischemic complications in clipping because DMCAs are easily deformed.
A tale of two sequences: microRNA-target chimeric reads.
Broughton, James P; Pasquinelli, Amy E
2016-04-04
In animals, a functional interaction between a microRNA (miRNA) and its target RNA requires only partial base pairing. The limited number of base pair interactions required for miRNA targeting provides miRNAs with broad regulatory potential and also makes target prediction challenging. Computational approaches to target prediction have focused on identifying miRNA target sites based on known sequence features that are important for canonical targeting and may miss non-canonical targets. Current state-of-the-art experimental approaches, such as CLIP-seq (cross-linking immunoprecipitation with sequencing), PAR-CLIP (photoactivatable-ribonucleoside-enhanced CLIP), and iCLIP (individual-nucleotide resolution CLIP), require inference of which miRNA is bound at each site. Recently, the development of methods to ligate miRNAs to their target RNAs during the preparation of sequencing libraries has provided a new tool for the identification of miRNA target sites. The chimeric, or hybrid, miRNA-target reads that are produced by these methods unambiguously identify the miRNA bound at a specific target site. The information provided by these chimeric reads has revealed extensive non-canonical interactions between miRNAs and their target mRNAs, and identified many novel interactions between miRNAs and noncoding RNAs.
Ingested bread clip as an unexpected diagnostic tool.
Jay, Sharon M; Russell, Michael J; Lau, Yee C; Dunn, Joel W; Roberts, Ross
2018-03-23
We describe a case where a bread clip has in fact became lodged adjacent to a portion of small bowel affected by a deposit of previously undiagnosed metastatic serous carcinoma of likely ovarian origin.
40 CFR 60.1940 - What definitions must I know?
Code of Federal Regulations, 2011 CFR
2011-07-01
... plastics or rubber recycling unit as specified under Applicability of State Plans (§ 60.1555(h) and (i...) of the combustion unit. Yard waste means grass, grass clippings, bushes, shrubs, and clippings from...
40 CFR 60.1940 - What definitions must I know?
Code of Federal Regulations, 2010 CFR
2010-07-01
... plastics or rubber recycling unit as specified under Applicability of State Plans (§ 60.1555(h) and (i...) of the combustion unit. Yard waste means grass, grass clippings, bushes, shrubs, and clippings from...
Object/rule integration in CLIPS. [C Language Integrated Production System
NASA Technical Reports Server (NTRS)
Donnell, Brian L.
1993-01-01
This paper gives a brief overview of the C Language Integrated Production System (CLIPS) with a focus on the object-oriented features. The advantages of an object data representation over the traditional working memory element (WME), i.e., facts, are discussed, and the implementation of the Rete inference algorithm in CLIPS is presented in detail. A few methods for achieving pattern-matching on objects with the current inference engine are given, and finally, the paper examines the modifications necessary to the Rete algorithm to allow direct object pattern-matching.
Influence of a negative movie message on food perceptions.
Oakes, Michael E; Slotterback, Carole S
2007-09-01
Many food scholars have suggested that popular media messages impact perceptions of foods. In the present study, experimental participants watched a disparaging video clip concerning McDonald's foods as well as a ruse video clip, then were asked to evaluate the healthfulness of 33 named foods as well as their nutrient descriptions. Control participants judged the named foods and their descriptions but saw no videos. The movie clip influenced only named foods that are identifiable with McDonalds and not other fast foods or other named foods that are considered unhealthy.
A CLIPS-based tool for aircraft pilot-vehicle interface design
NASA Technical Reports Server (NTRS)
Fowler, Thomas D.; Rogers, Steven P.
1991-01-01
The Pilot-Vehicle Interface of modern aircraft is the cognitive, sensory, and psychomotor link between the pilot, the avionics modules, and all other systems on board the aircraft. To assist pilot-vehicle interface designers, a C Language Integrated Production System (CLIPS) based tool was developed that allows design information to be stored in a table that can be modified by rules representing design knowledge. Developed for the Apple Macintosh, the tool allows users without any CLIPS programming experience to form simple rules using a point and click interface.
Flexibility in the parental effort of an Arctic-breeding seabird
Harding, A.M.A.; Kitaysky, A.S.; Hall, M.E.; Welcker, J.; Karnovsky, N.J.; Talbot, S.L.; Hamer, K.C.; Gremillet, D.
2009-01-01
Parental investment strategies are considered to represent a trade-off between the benefits of investment in current offspring and costs to future reproduction. Due to their high residual reproductive value, long-lived organisms are predicted to be more reluctant to increase parental effort. 2. We tested the hypothesis that breeding little auks (Alle alle) have a fixed level of reproductive investment, and thus reduce parental effort when costs associated with reproduction increase. 3. To test this hypothesis we experimentally increased the flight costs of breeding little auks via feather clipping. In 2005 we examined changes in the condition of manipulated parents, of the mates of manipulated parents, and of their chick as direct measures of change in parental resource allocation between self-maintenance and current reproduction. In 2007 we increased sample sizes to determine whether there was a physiological cost (elevated corticosterone, CORT) associated with the manipulation. 4. We found that: (i) clipped birds and their mates lost more body mass than controls, but there was no difference in mass loss between members of a pair; (ii) clipped birds had higher CORT levels than control birds; (iii) there were no inter-annual differences in body mass and CORT levels between clipped individuals and their mates at recapture, and (iv) chicks with a clipped parent had lower peak and fledging mass, and higher CORT levels than control chicks in both years. 5. Contrary to our hypothesis, the reduction in body mass of partners to clipped birds suggests that little auks can increase parental effort to some extent. Nonetheless, the lower fledging mass and higher CORT of chicks with a clipped parent indicates provisioning rates may not have been fully maintained. 6. As predicted by life-history theory, there may be a threshold to the additional reproductive costs breeders will accept, with parents prioritizing self-maintenance over increased provisioning effort when foraging costs become too high. ?? 2008 British Ecological Society.
Long-term results of middle cerebral artery aneurysm clipping in the Barrow Ruptured Aneurysm Trial.
Mooney, Michael A; Simon, Elias D; Brigeman, Scott; Nakaji, Peter; Zabramski, Joseph M; Lawton, Michael T; Spetzler, Robert F
2018-04-27
OBJECTIVE A direct comparison of endovascular versus microsurgical treatment of ruptured middle cerebral artery (MCA) aneurysms in randomized trials is lacking. As endovascular treatment strategies continue to evolve, the number of reports of endovascular treatment of these lesions is increasing. Herein, the authors report a detailed post hoc analysis of ruptured MCA aneurysms treated by microsurgical clipping from the Barrow Ruptured Aneurysm Trial (BRAT). METHODS The cases of patients enrolled in the BRAT who underwent microsurgical clipping for a ruptured MCA aneurysm were reviewed. Characteristics of patients and their clinical outcomes and long-term angiographic results were analyzed. RESULTS Fifty patients underwent microsurgical clipping of a ruptured MCA aneurysm in the BRAT, including 21 who crossed over from the endovascular treatment arm. Four patients with nonsaccular (e.g., dissecting, fusiform, or blister) aneurysms were excluded, leaving 46 patients for analysis. Most (n = 32; 70%) patients presented with a Hunt and Hess grade II or III subarachnoid hemorrhage, with a high prevalence of intraparenchymal blood (n = 23; 50%), intraventricular blood (n = 21; 46%), or both. At the last follow-up (up to 6 years after treatment), clinical outcomes were good (modified Rankin Scale score 0-2) in 70% (n = 19) of 27 Hunt and Hess grades I-III patients and in 36% (n = 4) of 11 Hunt and Hess grade IV or V patients. There were no instances of rebleeding after the surgical clipping of aneurysms in this series at the time of last clinical follow-up. CONCLUSIONS Microsurgical clipping of ruptured MCA aneurysms has several advantages over endovascular treatment, including durability over time. The authors report detailed outcome data of patients with ruptured MCA aneurysms who underwent microsurgical clipping as part of a prospective, randomized trial. These results should be used for comparison with future endovascular and surgical series to ensure that the best results are being achieved for patients with ruptured MCA aneurysms.
Tay, Edgar; Muda, Nasir; Yap, Jonathan; Muller, David W M; Santoso, Teguh; Walters, Darren L; Liu, Xianbao; Yamen, Eric; Jansz, Paul; Yip, James; Zambahari, Robaayah; Passage, Jurgen; Ding, Zee Pin; Wang, Jian'an; Scalia, Gregory; Soesanto, Amiliana M; Yeo, Khung Keong
2016-06-01
The objective of this study is to describe and compare the use of the MitraClip therapy in mitral regurgitation (MR) patients with degenerative MR (DMR) and functional MR (FMR). Percutaneous edge-to-edge repair of severe MR using the MitraClip device is approved for use in the USA for high risk DMR while European guidelines include its use in FMR patients as well. The MitraClip in the Asia-Pacific Registry (MARS) is a multicenter retrospective registry, involving eight sites in five Asia-Pacific countries. Clinical and echocardiographic characteristics, procedural outcomes and 1-month outcomes [death and major adverse events (MAE)] were compared between FMR and DMR patients treated with the MitraClip. A total of 163 patients were included from 2011 to 2014. The acute procedural success rates for FMR (95.5%, n = 84) and DMR (92%, n = 69) were similar (P = 0.515). 45% of FMR had ≥2 clips inserted compared to 60% of those with DMR (P = 0.064).The 30-day mortality rate for FMR and DMR was similar at 4.5% and 6.7% respectively (P = 0.555). The 30-day MAE rate was 9.2% for FMR and 14.7% for DMR (P = 0.281). Both FMR and DMR patients had significant improvements in the severity of MR and NYHA class after 30 days. There was a significantly greater reduction in left ventricular end-diastolic diameter (P = 0.002) and end systolic diameter (P = 0.017) in DMR than in FMR. The MitraClip therapy is a safe and efficacious treatment option for both FMR and DMR. Although, there is a significantly greater reduction in LV volumes in DMR, patients in both groups report clinical benefit with improvement in functional class. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, H; Yoon, J; Lee, E
Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed onmore » the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm.« less
The second-generation eCLIPs Endovascular Clip System: initial experience.
Chiu, Albert H; De Vries, Joost; O'Kelly, Cian J; Riina, Howard; McDougall, Ian; Tippett, Jonathan; Wan, Martina; de Oliveira Manoel, Airton Leonardo; Marotta, Thomas R
2018-02-01
OBJECTIVE Treatment of wide-necked intracranial aneurysms is associated with higher recanalization and complication rates; however, the most commonly used methods are not specifically designed to work in bifurcation lesions. To address these issues, the authors describe the evolution in the design and use of the eCLIPs (Endovascular Clip System) device, a novel hybrid stent-like assist device with flow diverter properties that was first described in 2008. METHODS A registry was established covering 13 international centers at which patients were treated with the second-generation eCLIPs device. Aneurysm morphology and rupture status, device neck coverage, coil retention, and procedural and late morbidity and mortality were recorded. For those patients who had undergone successful implantation more than 6 months earlier, the final imaging and clinical follow-up results and need for re-treatment were recorded. RESULTS Thirty-three patients were treated between June 2013 and September 2015. Twenty-five (76%) patients had successful placement of an eCLIPs device; 23 (92%) of these 25 patients had complete data. Eight cases of nondeployment occurred during the 1st year of use, consistent with a learning curve; no failures of deployment occurred thereafter. Two periprocedural transient ischemic attacks and 2 asymptomatic thrombotic events occurred. Twenty-one (91%) of 23 patients underwent follow-up at an average of 8 months (range 3-18 months); 9 (42.9%) of these 21 patients demonstrated an improvement in Raymond grade at follow-up; no cases of worsening Raymond grade were recorded, and 17 (81.0%) patients sustained a modified Raymond-Roy Classification class of I or II angiographic result at follow-up. Two delayed ruptures were recorded, both in previously coiled, symptomatic giant aneurysms where the device was used as a part of a salvage strategy. CONCLUSIONS The second-generation eCLIPs device is a viable treatment option for bifurcation aneurysms. The aneurysm occlusion rates in this initial clinical series are comparable to the initial experience with other bifurcation support devices.
Eleraky, Mohammed A; Setzer, Matthias; Papanastassiou, Ioannis D; Baaj, Ali A; Tran, Nam D; Katsares, Kiesha M; Vrionis, Frank D
2010-05-01
The vascular supply of the thoracic spinal cord depends on the thoracolumbar segmental arteries. Because of the small size and ventral course of these arteries in relation to the dorsal root ganglion and ventral root, they cannot be reliably identified during surgery by anatomic or morphologic criteria. Sacrificing them will most likely result in paraplegia. The goal of this study was to evaluate a novel method of intraoperative testing of a nerve root's contribution to the blood supply of the thoracic spinal cord. This is a clinical retrospective study of 49 patients diagnosed with thoracic spine tumors. Temporary nerve root clipping combined with motor-evoked potential (MEP) and somatosensory-evoked potential (SSEP) monitoring was performed; additionally, postoperative clinical evaluation was done and reported in all cases. All cases were monitored by SSEP and MEPs. The nerve root to be sacrificed was temporarily clipped using standard aneurysm clips, and SSEP/MEP were assessed before and after clipping. Four nerve roots were sacrificed in four cases, three nerve roots in eight cases, and two nerve roots in 22 cases. Nerve roots were sacrificed bilaterally in 12 cases. Most patients (47/49) had no changes in MEP/SSEP and had no neurological deficit postoperatively. One case of a spinal sarcoma demonstrated changes in MEP after temporary clipping of the left T11 nerve root. The nerve was not sacrificed, and the patient was neurologically intact after surgery. In another case of a sarcoma, MEPs changed in the lower limbs after ligation of left T9 nerve root. It was felt that it was a global event because of anesthesia. Postoperatively, the patient had complete paraplegia but recovered almost completely after 6 months. Temporary nerve root clipping combined with MEP and SSEP monitoring may enhance the impact of neuromonitoring in the intraoperative management of patients with thoracic spine tumors and favorably influence neurological outcome. Copyright 2010 Elsevier Inc. All rights reserved.
Comparison of clipping and coiling in elderly patients with unruptured cerebral aneurysms
Bekelis, Kimon; Gottlieb, Daniel J.; Su, Yin; O’Malley, A. James; Labropoulos, Nicos; Goodney, Philip; Lawton, Michael T.; MacKenzie, Todd A.
2016-01-01
OBJECTIVE The comparative effectiveness of the 2 treatment options—surgical clipping and endovascular coiling—for unruptured cerebral aneurysms remains an issue of debate and has not been studied in clinical trials. The authors investigated the association between treatment method for unruptured cerebral aneurysms and outcomes in elderly patients. METHODS The authors performed a cohort study of 100% of Medicare fee-for-service claims data for elderly patients who had treatment for unruptured cerebral aneurysms between 2007 and 2012. To control for measured confounding, the authors used propensity score conditioning and inverse probability weighting with mixed effects to account for clustering at the level of the hospital referral region (HRR). An instrumental variable (regional rates of coiling) analysis was used to control for unmeasured confounding and to create pseudo-randomization on the treatment method. RESULTS During the study period, 8705 patients underwent treatment for unruptured cerebral aneurysms and met the study inclusion criteria. Of these patients, 2585 (29.7%) had surgical clipping and 6120 (70.3%) had endovascular coiling. Instrumental variable analysis demonstrated no difference between coiling and clipping in 1-year postoperative mortality (OR 1.25, 95% CI 0.68–2.31) or 90-day readmission rate (OR 1.04, 95% CI 0.66–1.62). However, clipping was associated with a greater likelihood of discharge to rehabilitation (OR 6.39, 95% CI 3.85–10.59) and 3.6 days longer length of stay (LOS; 95% CI 2.90–4.71). The same associations were present in propensity score–adjusted and inverse probability– weighted models. CONCLUSIONS In a cohort of Medicare patients, there was no difference in mortality and the readmission rate between clipping and coiling of unruptured cerebral aneurysms. Clipping was associated with a higher rate of discharge to a rehabilitation facility and a longer LOS. PMID:27203150
Verberkmoes, Niels J; Akca, Ferdi; Vandevenne, Ann-Sofie; Jacobs, Luuk; Soliman Hamad, Mohamed A; van Straten, Albert H M
Besides mechanical and anatomical changes of the left atrium, epicardial closure of the left atrial appendage has also possible homeostatic effects. The aim of this study was to assess whether epicardial clipping of the left atrial appendage has different biochemical effects compared with complete removal of the left atrial appendage. Eighty-two patients were included and underwent a totally thoracoscopic AF ablation procedure. As part of the procedure, the left atrial appendage was excluded with an epicardial clip (n = 57) or the left atrial appendage was fully amputated with an endoscopic vascular stapler (n = 25). From all patients' preprocedural and postprocedural blood pressure, electrolytes and inflammatory parameters were collected. The mean age and left atrial volume index were comparable between the epicardial clip and stapler group (64 ± 8 years vs. 60 ± 9 years, P = non-significant; 44 ± 15 mL/m vs. 40 ± 13 mL/m, P = non-significant). Patients receiving left atrial appendage clipping had significantly elevated C-reactive protein levels compared with patients who had left atrial appendage stapling at the second, third, and fourth postoperative day (225 ± 84 mg/L vs. 149 ± 76 mg/L, P = 0.002, 244 ± 78 vs. 167 ± 76, P = 0.004, 190 ± 74 vs. 105 ± 48, P < 0.001, respectively). Patients had a significant decrease in sodium levels, systolic, and diastolic blood pressure at 24 and 72 hours after left atrial appendage closure. However, this was comparable for both the left atrial appendage clipping and stapling group. Increased activation of the inflammatory response was observed after left atrial appendage clipping compared with left atrial appendage stapling. Furthermore, a significant decrease in blood pressure was observed after surgical removal of the left atrial appendage. Whether the inflammatory response affects the outcome of arrhythmia surgery needs to be further evaluated.
NASA Astrophysics Data System (ADS)
Inada, Shunko A.; Fuchi, Shingo; Mori, Kensaku; Hasegawa, Junichi; Misawa, Kazunari; Nakanishi, Hayao
2015-03-01
In recent year, for the treatment of gastric cancer the laparoscopic surgery is performed, which has good benefits, such as low-burden, low-invasive and the efficacy is equivalent to the open surgery. For identify location of the tumor intraperitoneally for extirpation of the gastric cancer, several points of charcoal ink is injected around the primary tumor. However, in the time of laparoscopic operation, it is difficult to estimate specific site of primary tumor, because the injected charcoal ink diffusely spread to the area distant from the tumor in the stomach. Therefore, a broad area should be resected which results in a great stress for the patients. To overcome this problem, we focused in the near-infrared wavelength of 1000nm band which have high biological transmission. In this study, we developed a fluorescent clip which was realized with glass phosphor (Yb3+, Nd3+ doped to Bi2O3-B2O3 based glasses. λp: 976 nm, FWHM: 100 nm, size: 2x1x3 mm) and the laparoscopic fluorescent detection system for clip-derived near-infrared light. To evaluate clinical performance of a fluorescent clip and the laparoscopic fluorescent detection system, we used resected stomach (thickness: 13 mm) from the patients. Fluorescent clip was fixed on the gastric mucosa, and an excitation light (λ: 808 nm) was irradiated from outside of stomach for detection of fluorescence through stomach wall. As a result, fluorescence emission from the clip was successfully detected. Furthermore, we confirmed that detection sensitivity of the emission of fluorescence from the clip depends on the output power of the excitation light. We conformed that the fluorescent clip in combination with laparoscopic fluorescent detection system is very useful method to identify the exact location of the primary gastric cancer.
33 CFR 183.532 - Clips, straps, and hose clamps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.532 Clips... under § 183.590, a hose clamp installed on a fuel line system requiring metallic fuel lines or “USCG...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smeenk, Robert M., E-mail: r.m.smeenk@asz.nl; Kock, Mark C. J. M.; Elgersma, Otto E. H.
2011-02-15
This report describes a rare vascular complication of surgical placement of a marking clip and a possible approach to problem solving. A 55-year-old patient presented with loss of sensation in the fingers and loss of peripheral pulsations in the right arm 4 days after right upper lobectomy for a pT2N1 moderately differentiated adenocarcinoma of the lung. Duplex examination and computed tomography were performed the same day and showed a subtotal stenosis of the right subclavian artery, which was caused by the surgical placement of a metal clip to mark the surgical boundary. Selective angiography was subsequently performed. Percutaneous transluminal angioplastymore » (PTA) successfully dilated the stenosis and pushed the clip off. Flow in the right subclavian artery (RSA) was completely restored as were neurology and peripheral pulses. In conclusion, arterial stenosis by a surgical (marking) clip may be feasibly treated with PTA.« less
Rykov, S A; Torchinskaia, N V; Bakbardina, I I; Simchuk, I V
2011-10-01
The efficacy of hemostasis achievement during conduction of a retrobulbar vascular-nervous bunch ligation (RVNBL), using titanic clips while evisceroenucleation performance, was studied up. A comparative analysis of clinical and functional results of surgical treatment of 36 patients, suffering terminal dolorous glaucoma and disaster of a sympathetic ophthalmia complication after an eye penetrating wounding occurrence. In 16 patients (the first group) a standard method of a hemostasis achievement was used while doing evisceroenucleation - a deep orbital tamponade for 5 minutes. In 20 patients (the second group) a procedure of RVNBL was conducted, using titanic clips before the bunch transsection doing. There was established, that while doing a RVNPL using titanic clips, a hemorrhage never occurs, a retrobulbar hematoma do not formated, the soft tissues reaction in the early postoperative period is less pronounced, and the patients postoperative rehabilitation period shortens.
Reading your own lips: common-coding theory and visual speech perception.
Tye-Murray, Nancy; Spehar, Brent P; Myerson, Joel; Hale, Sandra; Sommers, Mitchell S
2013-02-01
Common-coding theory posits that (1) perceiving an action activates the same representations of motor plans that are activated by actually performing that action, and (2) because of individual differences in the ways that actions are performed, observing recordings of one's own previous behavior activates motor plans to an even greater degree than does observing someone else's behavior. We hypothesized that if observing oneself activates motor plans to a greater degree than does observing others, and if these activated plans contribute to perception, then people should be able to lipread silent video clips of their own previous utterances more accurately than they can lipread video clips of other talkers. As predicted, two groups of participants were able to lipread video clips of themselves, recorded more than two weeks earlier, significantly more accurately than video clips of others. These results suggest that visual input activates speech motor activity that links to word representations in the mental lexicon.
C-Language Integrated Production System, Version 6.0
NASA Technical Reports Server (NTRS)
Riley, Gary; Donnell, Brian; Ly, Huyen-Anh Bebe; Ortiz, Chris
1995-01-01
C Language Integrated Production System (CLIPS) computer programs are specifically intended to model human expertise or other knowledge. CLIPS is designed to enable research on, and development and delivery of, artificial intelligence on conventional computers. CLIPS 6.0 provides cohesive software tool for handling wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming: representation of knowledge as heuristics - essentially, rules of thumb that specify set of actions performed in given situation. Object-oriented programming: modeling of complex systems comprised of modular components easily reused to model other systems or create new components. Procedural-programming: representation of knowledge in ways similar to those of such languages as C, Pascal, Ada, and LISP. Version of CLIPS 6.0 for IBM PC-compatible computers requires DOS v3.3 or later and/or Windows 3.1 or later.
Bottini, Silvia; Hamouda-Tekaya, Nedra; Tanasa, Bogdan; Zaragosi, Laure-Emmanuelle; Grandjean, Valerie; Repetto, Emanuela; Trabucchi, Michele
2017-05-19
Experimental evidence indicates that about 60% of miRNA-binding activity does not follow the canonical rule about the seed matching between miRNA and target mRNAs, but rather a non-canonical miRNA targeting activity outside the seed or with a seed-like motifs. Here, we propose a new unbiased method to identify canonical and non-canonical miRNA-binding sites from peaks identified by Ago2 Cross-Linked ImmunoPrecipitation associated to high-throughput sequencing (CLIP-seq). Since the quality of peaks is of pivotal importance for the final output of the proposed method, we provide a comprehensive benchmarking of four peak detection programs, namely CIMS, PIPE-CLIP, Piranha and Pyicoclip, on four publicly available Ago2-HITS-CLIP datasets and one unpublished in-house Ago2-dataset in stem cells. We measured the sensitivity, the specificity and the position accuracy toward miRNA binding sites identification, and the agreement with TargetScan. Secondly, we developed a new pipeline, called miRBShunter, to identify canonical and non-canonical miRNA-binding sites based on de novo motif identification from Ago2 peaks and prediction of miRNA::RNA heteroduplexes. miRBShunter was tested and experimentally validated on the in-house Ago2-dataset and on an Ago2-PAR-CLIP dataset in human stem cells. Overall, we provide guidelines to choose a suitable peak detection program and a new method for miRNA-target identification. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
Bottini, Silvia; Hamouda-Tekaya, Nedra; Tanasa, Bogdan; Zaragosi, Laure-Emmanuelle; Grandjean, Valerie; Repetto, Emanuela
2017-01-01
Abstract Experimental evidence indicates that about 60% of miRNA-binding activity does not follow the canonical rule about the seed matching between miRNA and target mRNAs, but rather a non-canonical miRNA targeting activity outside the seed or with a seed-like motifs. Here, we propose a new unbiased method to identify canonical and non-canonical miRNA-binding sites from peaks identified by Ago2 Cross-Linked ImmunoPrecipitation associated to high-throughput sequencing (CLIP-seq). Since the quality of peaks is of pivotal importance for the final output of the proposed method, we provide a comprehensive benchmarking of four peak detection programs, namely CIMS, PIPE-CLIP, Piranha and Pyicoclip, on four publicly available Ago2-HITS-CLIP datasets and one unpublished in-house Ago2-dataset in stem cells. We measured the sensitivity, the specificity and the position accuracy toward miRNA binding sites identification, and the agreement with TargetScan. Secondly, we developed a new pipeline, called miRBShunter, to identify canonical and non-canonical miRNA-binding sites based on de novo motif identification from Ago2 peaks and prediction of miRNA::RNA heteroduplexes. miRBShunter was tested and experimentally validated on the in-house Ago2-dataset and on an Ago2-PAR-CLIP dataset in human stem cells. Overall, we provide guidelines to choose a suitable peak detection program and a new method for miRNA-target identification. PMID:28108660
Development of mitral stenosis after single MitraClip insertion for severe mitral regurgitation.
Cockburn, James; Fragkou, Paraskevi; Hildick-Smith, David
2014-02-01
We report the first case of mitral stenosis following Mitra-Clip insertion in a patient with symptomatic NYHA IV heart failure, secondary to severe mitral regurgitation (MR). A 79-year-old female with a history of prior aortic valve replacement underwent percutaneous mitral valve (MV) repair. A single clip was advanced coaxially down onto the MV under TOE guidance, with the anterior and posterior leaflets clipped together between A2 and P2. TOE confirmed a significant reduction in MR (grade 4 to grade 1). Despite initial symptomatic relief, she represented 3 months later with similar symptoms. Repeat TOE confirmed a well positioned Mitra-Clip with mild residual MR. However, the possibility of significant mitral stenosis was raised due to the presence of significant turbulence through the bi-orifice valve, with a peak gradient of 25 mm Hg. In addition there was evidence of severe functional tricuspid valve (TV) regurgitation with elevated pulmonary artery pressures (PAP 90 mm Hg), confirmed on subsequent right heart catheterization. After repeated heart team discussions and a failure of optimal medical therapy, and despite a logistic EuroScore of 35.5, minimally invasive surgical replacement of the MV and simultaneous TV repair was undertaken via a right thoracotomy. Despite procedural success and initial good postoperative response, the patient died subsequently from a combination of hospital-acquired pneumonia and significant gastrointestinal bleeding (post operative day 35). Mitra-Clip is a promising novel approach to MV repair. The establishment of further clinical and echocardiographic based selection criteria will help identify the correct patients for this treatment. Copyright © 2013 Wiley Periodicals, Inc.
Genome-Wide Profiling of RNA–Protein Interactions Using CLIP-Seq
Stork, Cheryl; Zheng, Sika
2017-01-01
UV crosslinking immunoprecipitation (CLIP) is an increasingly popular technique to study protein–RNA interactions in tissues and cells. Whole cells or tissues are ultraviolet irradiated to generate a covalent bond between RNA and proteins that are in close contact. After partial RNase digestion, antibodies specific to an RNA binding protein (RBP) or a protein–epitope tag is then used to immunoprecipitate the protein–RNA complexes. After stringent washing and gel separation the RBP–RNA complex is excised. The RBP is protease digested to allow purification of the bound RNA. Reverse transcription of the RNA followed by high-throughput sequencing of the cDNA library is now often used to identify protein bound RNA on a genome-wide scale. UV irradiation can result in cDNA truncations and/or mutations at the crosslink sites, which complicates the alignment of the sequencing library to the reference genome and the identification of the crosslinking sites. Meanwhile, one or more amino acids of a crosslinked RBP can remain attached to its bound RNA due to incomplete digestion of the protein. As a result, reverse transcriptase may not read through the crosslink sites, and produce cDNA ending at the crosslinked nucleotide. This is harnessed by one variant of CLIP methods to identify crosslinking sites at a nucleotide resolution. This method, individual nucleotide resolution CLIP (iCLIP) circularizes cDNA to capture the truncated cDNA and also increases the efficiency of ligating sequencing adapters to the library. Here, we describe the detailed procedure of iCLIP. PMID:26965263
Nikendei, Christoph; Schäfer, Hannah; Weisbrod, Matthias; Huber, Julia; Geis, Nicolas; Katus, Hugo A; Bekeredjian, Raffi; Herzog, Wolfgang; Pleger, Sven T; Schultz, Jobst-Hendrik
2016-05-01
Heart failure (HF) is a prevalent disease that remains costly and associated with a high mortality rate. HF is also associated with poor neurocognitive functioning. For the treatment for HF patients with severe mitral regurgitation, the MitraClip device has emerged as a promising interventional tool that reduces the mitral valve leakage and thus increases cardiac output. Currently, there is only limited knowledge on changes in cognitive and psychosocial functioning before and after the MitraClip intervention. Cognitive function (memory and executive function) and psychosocial measures (depression, anxiety, and quality of life) were assessed before and after the MitraClip intervention in 24 HF patients and 23 healthy participants (comparison group). MitraClip intervention in HF patients was followed by improvements in figural long-term memory (p = .003) and executive function (planning ability, p < .001) relative to the comparison group. In addition, the intervention resulted in a significant improvement in depression (p = .002), anxiety (p = .003) and quality of life scores (physical p = .017, mental p = .013) as well as improved 6-minute walk test results over time (p = .002). The presented data provide evidence of a significant improvement in memory and executive function as well as in depression, anxiety, and quality of life scores in patients with chronic HF after MitraClip intervention. Further research is needed to shed light on the long-term development of cognitive function, psychosocial well-being, and clinical parameters after MitraClip intervention and how these factors depend on one another.
Is perception of quality more important than technical quality in patient video cases?
Roland, Damian; Matheson, David; Taub, Nick; Coats, Tim; Lakhanpaul, Monica
2015-08-13
The use of video cases to demonstrate key signs and symptoms in patients (patient video cases or PVCs) is a rapidly expanding field. The aims of this study were to evaluate whether the technical quality, or judgement of quality, of a video clip influences a paediatrician's judgment on acuity of the case and assess the relationship between perception of quality and the technical quality of a selection of video clips. Participants (12 senior consultant paediatricians attending an examination workshop) individually categorised 28 PVCs into one of 3 possible acuities and then described the quality of the image seen. The PVCs had been converted into four different technical qualities (differing bit rates ranging from excellent to low quality). Participants' assessment of quality and the actual industry standard of the PVC were independent (333 distinct observations, spearmans rho = 0.0410, p = 0.4564). Agreement between actual acuity and participants' judgement was generally good at higher acuities but moderate at medium/low acuities of illness (overall correlation 0.664). Perception of the quality of the clip was related to correct assignment of acuity regardless of the technical quality of the clip (number of obs = 330, z = 2.07, p = 0.038). It is important to benchmark PVCs prior to use in learning resources as experts may not agree on the information within, or quality of, the clip. It appears, although PVCs may be beneficial in a pedagogical context, the perception of quality of clip may be an important determinant of an expert's decision making.
Microsurgical Clipping of an Unruptured Carotid Cave Aneurysm: 3-Dimensional Operative Video.
Tabani, Halima; Yousef, Sonia; Burkhardt, Jan-Karl; Gandhi, Sirin; Benet, Arnau; Lawton, Michael T
2017-08-01
Most aneurysms originating from the clinoidal segment of the internal carotid artery (ICA) are nowadays managed conservatively, treated endovascularly with coiling (with or without stenting) or flow diverters. However, microsurgical clip occlusion remains an alternative. This video demonstrates clip occlusion of an unruptured right carotid cave aneurysm measuring 7 mm in a 39-year-old woman. The patient opted for surgery because of concerns about prolonged antiplatelet use associated with endovascular therapy. After patient consent, a standard pterional craniotomy was performed followed by extradural anterior clinoidectomy. After dural opening and sylvian fissure split, a clinoidal flap was opened to enter the extradural space around the clinoidal segment. The dural ring was dissected circumferentially, freeing the medial wall of the ICA down to the sellar region and mobilizing the ICA out of its canal of the clinoidal segment. With the aneurysm neck in view, the aneurysm was clipped with a 45° angled fenestrated clip over the ICA. Indocyanine green angiography confirmed no further filling of the aneurysm and patency of the ICA. Complete aneurysm occlusion was confirmed with postoperative angiography, and the patient had no neurologic deficits (Video 1). This case demonstrates the importance of anterior clinoidectomy and thorough distal dural ring dissection for effective clipping of carotid cave aneurysms. Control of venous bleeding from the cavernous sinus with fibrin glue injection simplifies the dissection, which should minimize manipulation of the optic nerve. Knowledge of this anatomy and proficiency with these techniques is important in an era of declining open aneurysm cases. Copyright © 2017 Elsevier Inc. All rights reserved.
Li, Lai-Fung; Leung, Gilberto Ka-Kit; Lui, Wai-Man
2017-02-01
High-flow extracranial-intracranial (EC-IC) bypass followed by sacrifice of the native internal carotid artery (ICA) is a recognized treatment option for giant ICA aneurysm and skull base tumor involving the ICA. Distal clipping at the supraclinoid portion of the ICA is technically straightforward, but it can potentially compromise ophthalmic artery (OA) perfusion. Because of the extensive EC-IC anastomoses with the OA, visual symptoms are fortunately uncommon. We report a patient who developed complete blindness after distal trapping of the supraclinoid ICA; it was reversed after emergency clip removal. Our patient is a 47-year-old man with recurrent nasopharyngeal carcinoma in close proximity to the left petrosal ICA. The first stage of the procedure involved an EC-IC bypass using radial artery graft, followed by a second stage with combined craniofacial excision. Trapping of the native ICA was achieved using a permanent aneurysm clip placed at the supraclinoid ICA distal to the origin of the OA. He complained of a new onset of complete left eye visual loss approximately 6 hours after the distal aneurysm clip was applied. He was immediately sent to the operating theatre for the removal of the supraclinoid aneurysm clip. On the next day, his vision improved and left pupil became reactive again. OA flow following ICA trapping is complicated and precarious. Delayed onset of visual loss is possible. Prompt action by direct exploration and clip removal is needed and can be effective in reversing blindness. Copyright © 2016 Elsevier Inc. All rights reserved.
26. VIEW SHOWING SOUTH ELEVATION, LOOKING NORTHEAST From newspaper clipping, ...
26. VIEW SHOWING SOUTH ELEVATION, LOOKING NORTHEAST From newspaper clipping, 'Notre Dame Bridge, Manchester, New Hampshire', Manchester Union Leader, c. 1938, photographer unknown. - Notre Dame Bridge, Spanning Merrimack River on Bridge Street, Manchester, Hillsborough County, NH
CDC Vital Signs: Prescription Painkiller Overdoses (Methadone)
... or www.samhsa.gov/treatment/ ). Top of Page Science Behind the Issue MMWR Science Clips Related Pages Vital Signs Issue details: Morbidity ... factsheet [PDF – 1.34 MB] Read the MMWR Science Clips File Formats Help: How do I view ...
NASA Astrophysics Data System (ADS)
Riendeau, Diane
2011-05-01
As we finish this publishing cycle, I'd like to thank all the readers who sent in video clips. If you have a YouTube clip that you use in class, please send the link and a brief description to driendeau@dist113.org.
Egeto, Peter; Loch Macdonald, R; Ornstein, Tisha J; Schweizer, Tom A
2018-03-01
OBJECTIVE Subarachnoid hemorrhage (SAH) is treated with either surgical clipping or endovascular coiling, though the latter is the preferred treatment method given its more favorable functional outcomes. However, neuropsychological functioning after treatment is rarely taken into account. In this meta-analysis, the authors synthesized relevant data from the literature and compared neuropsychological functioning in patients after coiling and clipping of SAH. They hypothesized that the coiled patients would outperform the clipped patients; that group differences would be greater with higher posterior circulation rupture rates, in older patients, and in more recent publications; that group differences would be smaller with greater rates of middle cerebral artery (MCA) rupture; and that anterior communicating artery (ACoA) rupture rates would not influence effect sizes. METHODS The MEDLINE, Embase, and PsycINFO databases were searched for clinical studies that compared neuropsychological functioning after either endovascular coiling or surgical clipping for SAH. Hedge's g and 95% confidence intervals were calculated using random effects models. Patients who had undergone coiling or clipping were compared on test performance in 8 neuropsychological domains: executive functions, language, attention/processing speed, verbal memory, visual memory, spatial memory, visuospatial functions, and intelligence. Patients were also compared with healthy controls, and meta-regressions were used to explore the relation between effect sizes and publication year, delay between treatment and neuropsychological testing, mean patient age, and rates of posterior circulation, ACoA, and MCA ruptures. RESULTS Thirteen studies with 396 clipped cases, 314 coiled cases, and 169 healthy controls were included in the study. The coil-treated patients outperformed the clip-treated patients on executive function (g = 0.17, 95% CI 0.08-0.25) and language tests (g = 0.23, 95% CI 0.07-0.39), and all patients were impaired relative to healthy controls (g ranged from -0.93 to -0.29). Coiled patients outperformed clipped patients to a greater degree in more recent publications, over longer posttreatment testing delays, and among older patients. Higher rates of posterior circulation and MCA aneurysms were associated with smaller group differences, while ACoA rupture rates did not influence effect sizes. CONCLUSIONS Coiling of SAH may promote superior neuropsychological functioning under certain circumstances and could have applications for the specialized care of SAH patients.
Analysis of saccular aneurysms in the Barrow Ruptured Aneurysm Trial.
Spetzler, Robert F; Zabramski, Joseph M; McDougall, Cameron G; Albuquerque, Felipe C; Hills, Nancy K; Wallace, Robert C; Nakaji, Peter
2018-01-01
OBJECTIVE The Barrow Ruptured Aneurysm Trial (BRAT) is a prospective, randomized trial in which treatment with clipping was compared to treatment with coil embolization. Patients were randomized to treatment on presentation with any nontraumatic subarachnoid hemorrhage (SAH). Because all other randomized trials comparing these 2 types of treatments have been limited to saccular aneurysms, the authors analyzed the current BRAT data for this subgroup of lesions. METHODS The primary BRAT analysis included all sources of SAH: nonaneurysmal lesions; saccular, blister, fusiform, and dissecting aneurysms; and SAHs from an aneurysm associated with either an arteriovenous malformation or a fistula. In this post hoc review, the outcomes for the subgroup of patients with saccular aneurysms were further analyzed by type of treatment. The extent of aneurysm obliteration was adjudicated by an independent neuroradiologist not involved in treatment. RESULTS Of the 471 patients enrolled in the BRAT, 362 (77%) had an SAH from a saccular aneurysm. Patients with saccular aneurysms were assigned equally to the clipping and the coiling cohorts (181 each). In each cohort, 3 patients died before treatment and 178 were treated. Of the 178 clip-assigned patients with saccular aneurysms, 1 (1%) was crossed over to coiling, and 64 (36%) of the 178 coil-assigned patients were crossed over to clipping. There was no statistically significant difference in poor outcome (modified Rankin Scale score > 2) between these 2 treatment arms at any recorded time point during 6 years of follow-up. After the initial hospitalization, 1 of 241 (0.4%) clipped saccular aneurysms and 21 of 115 (18%) coiled saccular aneurysms required retreatment (p < 0.001). At the 6-year follow-up, 95% (95/100) of the clipped aneurysms were completely obliterated, compared with 40% (16/40) of the coiled aneurysms (p < 0.001). There was no difference in morbidity between the 2 treatment groups (p = 0.10). CONCLUSIONS In the subgroup of patients with saccular aneurysms enrolled in the BRAT, there was no significant difference between modified Rankin Scale outcomes at any follow-up time in patients with saccular aneurysms assigned to clipping compared with those assigned to coiling (intent-to-treat analysis). At the 6-year follow-up evaluation, rates of retreatment and complete aneurysm obliteration significantly favored patients who underwent clipping compared with those who underwent coiling. Clinical trial registration no.: NCT01593267 (clinicaltrials.gov).
ERIC Educational Resources Information Center
Keller, Rodney D.
1987-01-01
Recommends using movie clips to stimulate students' interest in reading a novel as well as to teach elements of fiction such as plot, character, setting, symbol, irony, and theme. Describes each clip and provides study questions. Includes a listing of movies made from books. (NH)
Laparoscopic Filshie clip sterilization and selective use of the methylene blue dye test.
Karoshi, Mahantesh; Yoong, Wai
2004-01-01
In laparoscopic Filshie clip sterilization, difficulties may arise in identifying the length of the fallopian tube, with the possibility of failure of sterilization. This article describes a novel intraoperative method of demonstrating adequate tubal closure.
Second CLIPS Conference Proceedings, volume 1
NASA Technical Reports Server (NTRS)
Giarratano, Joseph (Editor); Culbert, Christopher J. (Editor)
1991-01-01
Topics covered at the 2nd CLIPS Conference held at the Johnson Space Center, September 23-25, 1991 are given. Topics include rule groupings, fault detection using expert systems, decision making using expert systems, knowledge representation, computer aided design and debugging expert systems.
Migrated Hem-o-Lok clips in the ureter: a rare cause of recurrent urinary tract infection.
Shrivastava, Prashant; Nayak, Brusabhanu; Singh, Prabhjot
2017-02-15
Erosion of surgical materials into the adjacent organs following surgical procedures is a rare complication. Migrations of these surgical materials into the urinary tract like pelvicalyceal system, ureter and bladder have been reported following various urological procedures. We present a case of migrated Hem-o-Lok clips into the ureter following a laparoscopic partial nephrectomy for angiomyolipoma of the left kidney presented with recurrent urinary tract infection. The case was managed with ureteroscopic removal of clips. The patient is asymptomatic on last follow-up. 2017 BMJ Publishing Group Ltd.
Zupan, Barbra; Neumann, Dawn
2016-01-01
The current study presented 60 people with traumatic brain injury (TBI) and 60 controls with isolated facial emotion expressions, isolated vocal emotion expressions, and multimodal (i.e., film clips) stimuli that included contextual cues. All stimuli were presented via computer. Participants were required to indicate how the person in each stimulus was feeling using a forced-choice format. Additionally, for the film clips, participants had to indicate how they felt in response to the stimulus, and the level of intensity with which they experienced that emotion. PMID:27213280
Using a CLIPS expert system to automatically manage TCP/IP networks and their components
NASA Technical Reports Server (NTRS)
Faul, Ben M.
1991-01-01
A expert system that can directly manage networks components on a Transmission Control Protocol/Internet Protocol (TCP/IP) network is described. Previous expert systems for managing networks have focused on managing network faults after they occur. However, this proactive expert system can monitor and control network components in near real time. The ability to directly manage network elements from the C Language Integrated Production System (CLIPS) is accomplished by the integration of the Simple Network Management Protocol (SNMP) and a Abstract Syntax Notation (ASN) parser into the CLIPS artificial intelligence language.
C-Language Integrated Production System, Version 5.1
NASA Technical Reports Server (NTRS)
Riley, Gary; Donnell, Brian; Ly, Huyen-Anh VU; Culbert, Chris; Savely, Robert T.; Mccoy, Daniel J.; Giarratano, Joseph
1992-01-01
CLIPS 5.1 provides cohesive software tool for handling wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming provides representation of knowledge by use of heuristics. Object-oriented programming enables modeling of complex systems as modular components. Procedural programming enables CLIPS to represent knowledge in ways similar to those allowed in such languages as C, Pascal, Ada, and LISP. Working with CLIPS 5.1, one can develop expert-system software by use of rule-based programming only, object-oriented programming only, procedural programming only, or combinations of the three.
Rosenthal, T; Bass, A; Grossman, E; Shani, M; Griffel, B; Adar, R
1987-09-01
Renovascular hypertension superimposed on essential hypertension, a condition encountered in the elderly, was studied. An experimental animal model consisting of a two-kidney one-clip Goldblatt preparation in the spontaneous hypertensive (SHR) rat, that would simulate this condition, was designed. A 0.25 mm silver clip was placed on the left renal artery of SHR male rats. The same procedure performed on WKY rats served as control. All experiments were performed on low, normal, and rich sodium diet. Systolic blood pressure (BP) was measured by tail-cuff method. Plasma renin concentration (PRC) was determined before and after clipping of the renal artery. Results were as follows: Mean systolic BP increased significantly in clipped rats fed with normal and rich sodium diets. SHR showed an increase from 144 +/- 3 (mean + s.e.m.) to 168 +/- 3 mmHg, and WKY rats showed an increase from 120 +/- 2 to 139 +/- 5 mmHg. There was a two- to threefold rise in PRC. A low-salt diet given prior to clipping prevented the appearance of renovascular hypertension despite a significant rise in PRC. We concluded that renal artery narrowing plays a significant role in the rise of BP in the basically essential type of hypertension.
Barbiero, Isabella; Peroni, Diana; Tramarin, Marco; Chandola, Chetan; Rusconi, Laura; Landsberger, Nicoletta; Kilstrup-Nielsen, Charlotte
2017-09-15
CDKL5 is a protein kinase that plays a key role for neuronal functions as testified by the onset of complex neuronal dysfunctions in patients with genetic lesions in CDKL5. Here we identify a novel interactor of CDKL5, IQGAP1, a fundamental regulator of cell migration and polarity. In accordance with a functional role of this interaction, depletion of CDKL5 impairs cell migration and impedes the localization of IQGAP1 at the leading edge. Moreover, we demonstrate that CDKL5 is required for IQGAP1 to form a functional complex with its effectors, Rac1 and the microtubule plus end tracking protein CLIP170. These defects eventually impact on the microtubule association of CLIP170, thus deranging their dynamics. CLIP170 is a cellular target of the neurosteroid pregnenolone; by blocking CLIP170 in its active conformation, pregnenolone is capable of restoring the microtubule association of CLIP170 in CDKL5 deficient cells and rescuing morphological defects in neurons devoid of CDKL5. These findings provide novel insights into CDKL5 functions and pave the way for target-specific therapeutic strategies for individuals affected with CDKL5-disorder. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
A comparison of CLIPS- and LISP-based approaches to the development of a real-time expert system
NASA Technical Reports Server (NTRS)
Frainier, R.; Groleau, N.; Bhatnagar, R.; Lam, C.; Compton, M.; Colombano, S.; Lai, S.; Szolovits, P.; Manahan, M.; Statler, I.
1990-01-01
This paper describes an ongoing expert system development effort started in 1988 which is evaluating both CLIPS- and LISP- based approaches. The expert system is being developed to a project schedule and is planned for flight on Space Shuttle Mission SLS-2 in 1992. The expert system will help astronauts do the best possible science for a vestibular physiology experiment already scheduled for that mission. The system gathers and reduces data from the experiment, flags 'interesting' results, and proposes changes in the experiment both to exploit the in-flight observations and to stay within the time allowed by Mission Control for the experiment. These tasks must all be performed in real time. Two Apple Macintosh computers are used. The CLIPS- and LISP- based environments are layered above the Macintosh computer Operating System. The 'CLIPS-based' environment includes CLIPS and HyperCard. The LlSP-based environment includes Common LISP, Parmenides (a frame system), and FRuleKit (a rule system). Important evaluation factors include ease of programming, performance against real-time requirements, usability by an astronaut, robustness, and ease of maintenance. Current results on the factors of ease of programming, performance against real-time requirements, and ease of maintenance are discussed.
Dawkins, Lynne; Acaster, Sarah; Powell, Jane H
2007-02-01
Incentive motivation theories of addiction suggest that behavioural concomitants of compromised mesocorticolimbic reward activity during abstinence might include decreased affective reactions to natural reinforcers. This study tested implications for hedonic reactions in abstinent smokers. It was hypothesised that positively valenced (pleasurable) film clips would elicit lower ratings of happiness in abstinent than satiated smokers. Twenty-nine smokers, randomly assigned to either an 'abstinent' or a 'satiated' condition, and 15 non-smokers took part in a single session in which they rated (i) signs and symptoms of nicotine withdrawal and (ii) affective responses to positively valenced, negatively valenced, and neutral film clips. Compared with satiated smokers, abstinent smokers rated positive clips as eliciting significantly lower levels of happiness, and this was independent of self-reported nicotine withdrawal symptoms; the scores of non-smokers fell between those of abstinent and satiated smokers, more closely approximating those of the latter. By contrast, sadness ratings in response to negative clips were not affected by smoking status, indicating that the effect on happiness was not simply due to general emotional blunting. These results suggest that, for regular smokers, stimuli that are motivationally salient for the general population may elicit reduced positive affective responses during periods of abstinence.
Kortelainen, Jukka; Väyrynen, Eero; Seppänen, Tapio
2015-01-01
Recent findings suggest that specific neural correlates for the key elements of basic emotions do exist and can be identified by neuroimaging techniques. In this paper, electroencephalogram (EEG) is used to explore the markers for video-induced emotions. The problem is approached from a classifier perspective: the features that perform best in classifying person's valence and arousal while watching video clips with audiovisual emotional content are searched from a large feature set constructed from the EEG spectral powers of single channels as well as power differences between specific channel pairs. The feature selection is carried out using a sequential forward floating search method and is done separately for the classification of valence and arousal, both derived from the emotional keyword that the subject had chosen after seeing the clips. The proposed classifier-based approach reveals a clear association between the increased high-frequency (15-32 Hz) activity in the left temporal area and the clips described as "pleasant" in the valence and "medium arousal" in the arousal scale. These clips represent the emotional keywords amusement and joy/happiness. The finding suggests the occurrence of a specific neural activation during video-induced pleasant emotion and the possibility to detect this from the left temporal area using EEG.
Kitagawa, Yoshiyasu; Suzuki, Takuto; Hara, Taro; Yamaguchi, Taketo
2018-01-01
Although endoscopic submucosal dissection (ESD) is an accepted and established treatment for early esophageal squamous cell carcinoma (EESCC), it is technically difficult, time consuming, and less safe than endoscopic mucosal resection. To perform ESD safely and more efficiently, we proposed a new technique of esophageal ESD using an IT knife nano with the clip traction method. This study aimed to evaluate the efficacy and safety of ESD using this new technique. We retrospectively reviewed all consecutive cases of esophageal ESD performed using an IT knife nano with the clip traction method at our hospital between March 2013 and January 2017. Therapeutic efficacy and safety were also assessed. A total of 103 patients underwent esophageal ESD using the IT knife nano with the clip traction method. In all cases, we performed en bloc resection. Complete resection was achieved in 100 cases (97.1%). The median operating time was 40 (range 13-230) min. No cases of perforation or delayed bleeding occurred. Although two cases (2.0%) of mediastinal emphysema occurred without visible perforation at endoscopy, all were successfully managed conservatively. The new technique of esophageal ESD using the IT knife nano with the clip traction method appears to be feasible, effective, and safe for EESCC treatment.
Ocular Biocompatibility of Nitinol Intraocular Clips
Velez-Montoya, Raul; Erlanger, Michael
2012-01-01
Purpose. To evaluate the tolerance and biocompatibility of a preformed nitinol intraocular clip in an animal model after anterior segment surgery. Methods. Yucatan mini-pigs were used. A 30-gauge prototype injector was used to attach a shape memory nitinol clip to the iris of five pigs. Another five eyes received conventional polypropylene suture with a modified Seipser slip knot. The authors compared the surgical time of each technique. All eyes underwent standard full-field electroretinogram at baseline and 8 weeks after surgery. The animals were euthanized and eyes collected for histologic analysis after 70 days (10 weeks) postsurgery. The corneal thickness, corneal endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram parameters were compared between the groups. A two sample t-test for means and a P value of 0.05 were use for assessing statistical differences between measurements. Results. The injection of the nitinol clip was 15 times faster than conventional suturing. There were no statistical differences between the groups for corneal thickness, endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram measurements. Conclusions. The nitinol clip prototype is well tolerated and showed no evidence of toxicity in the short-term. The injectable delivery system was faster and technically less challenging than conventional suture techniques. PMID:22064995
Tang, Gilbert H L; Kaple, Ryan; Cohen, Martin; Dutta, Tanya; Undemir, Cenap; Ahmad, Hasan; Poniros, Angelica; Bennett, Joanne; Feng, Cheng; Lansman, Steven
2017-02-03
Pacemaker lead-associated severe tricuspid regurgitation (TR) can lead to right heart failure and poor prognosis. Surgery in these patients carries significant morbidities. We describe a successful treatment of symptomatic severe TR by leadless pacemaker implantation followed by tricuspid valve (TV) repair with the MitraClip NT. A 71-year-old frail female with poor functional status, chronic atrial fibrillation and permanent pacemaker implantation in 2012 presented with symptomatic moderate-severe mitral regurgitation (MR) and severe TR with the pacemaker lead as the culprit. She was deemed extreme risk for double valve surgery and, because of her pacemaker dependency, the decision was to stage her interventions first with transcatheter mitral repair, then laser lead extraction and leadless pacemaker implantation to free the TV from tethering, then TV repair. An obstructive LAD lesion was identified and treated during mitral repair with the MitraClip NT. The Micra leadless pacemaker implantation and subsequent TV repair with the MitraClip NT were successful and the patient's MR improved to mild and TR to moderate, respectively. We report here a first successful transcatheter strategy to treat lead-associated severe TR by leadless pacemaker and MitraClip. Removing the pacemaker lead relieved leaflet tethering and improved the reparability of the TV.
Diminished facial emotion expression and associated clinical characteristics in Anorexia Nervosa.
Lang, Katie; Larsson, Emma E C; Mavromara, Liza; Simic, Mima; Treasure, Janet; Tchanturia, Kate
2016-02-28
This study aimed to investigate emotion expression in a large group of children, adolescents and adults with Anorexia Nervosa (AN), and investigate the associated clinical correlates. One hundred and forty-one participants (AN=66, HC= 75) were recruited and positive and negative film clips were used to elicit emotion expressions. The Facial Activation Coding system (FACES) was used to code emotion expression. Subjective ratings of emotion were collected. Individuals with AN displayed less positive emotions during the positive film clip compared to healthy controls (HC). There was no significant difference between the groups on the Positive and Negative Affect Scale (PANAS). The AN group displayed emotional incongruence (reporting a different emotion to what would be expected given the stimuli, with limited facial affect to signal the emotion experienced), whereby they reported feeling significantly higher rates of negative emotion during the positive clip. There were no differences in emotion expression between the groups during the negative film clip. Despite this individuals with AN reported feeling significantly higher levels of negative emotions during the negative clip. Diminished positive emotion expression was associated with more severe clinical symptoms, which could suggest that these individuals represent a group with serious social difficulties, which may require specific attention in treatment. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Rassaf, Tienush; Balzer, Jan; Rammos, Christos; Zeus, Tobias; Hellhammer, Katharina; v Hall, Silke; Wagstaff, Rabea; Kelm, Malte
2015-04-01
In patients with mitral regurgitation (MR), changes in cardiac stroke volume, and thus renal preload and afterload may affect kidney function. Percutaneous mitral valve repair (PMVR) with the MitraClip® system can be a therapeutic alternative to surgical valve repair. The influence of MitraClip® therapy on renal function and clinical outcome parameters is unknown. Sixty patients with severe MR underwent PMVR using the MitraClip® system in an open-label observational study. Patients were stratified according to their renal function. All clips have been implanted successfully. Effective reduction of MR by 2-3 grades acutely improved KDOQI class. Lesser MR reduction (MR reduction of 0-1 grades) led to worsening of renal function in patients with pre-existing normal or mild (KDOQI 1-2) compared to severe (KDOQI 3-4) renal dysfunction. Reduction of MR was associated with improvement in Minnesota Living with Heart Failure Questionnaire (MLHFQ), NYHA-stadium, and 6-minute walk test. Successful PMVR was associated with an improvement in renal function. The improvement in renal function was associated with the extent of MR reduction and pre-existing kidney dysfunction. Our data emphasize the relevance of PVMR to stabilize the cardiorenal axis in patients with severe MR. © 2014 Wiley Periodicals, Inc.
Mahmud, Mahmud Abdulkader; Spigt, Mark; Bezabih, Afework Mulugeta; Pavon, Ignacio Lopez; Dinant, Geert-Jan; Velasco, Roman Blanco
2015-01-01
Background Intestinal parasitic infections are highly endemic among school-aged children in resource-limited settings. To lower their impact, preventive measures should be implemented that are sustainable with available resources. The aim of this study was to assess the impact of handwashing with soap and nail clipping on the prevention of intestinal parasite reinfections. Methods and Findings In this trial, 367 parasite-negative school-aged children (aged 6–15 y) were randomly assigned to receive both, one or the other, or neither of the interventions in a 2 × 2 factorial design. Assignment sequence was concealed. After 6 mo of follow-up, stool samples were examined using direct, concentration, and Kato-Katz methods. Hemoglobin levels were determined using a HemoCue spectrometer. The primary study outcomes were prevalence of intestinal parasite reinfection and infection intensity. The secondary outcome was anemia prevalence. Analysis was by intention to treat. Main effects were adjusted for sex, age, drinking water source, latrine use, pre-treatment parasites, handwashing with soap and nail clipping at baseline, and the other factor in the additive model. Fourteen percent (95% CI: 9% to 19%) of the children in the handwashing with soap intervention group were reinfected versus 29% (95% CI: 22% to 36%) in the groups with no handwashing with soap (adjusted odds ratio [AOR] 0.32, 95% CI: 0.17 to 0.62). Similarly, 17% (95% CI: 12% to 22%) of the children in the nail clipping intervention group were reinfected versus 26% (95% CI: 20% to 32%) in the groups with no nail clipping (AOR 0.51, 95% CI: 0.27 to 0.95). Likewise, following the intervention, 13% (95% CI: 8% to 18%) of the children in the handwashing group were anemic versus 23% (95% CI: 17% to 29%) in the groups with no handwashing with soap (AOR 0.39, 95% CI: 0.20 to 0.78). The prevalence of anemia did not differ significantly between children in the nail clipping group and those in the groups with no nail clipping (AOR 0.53, 95% CI: 0.27 to 1.04). The intensive follow-up and monitoring during this study made it such that the assessment of the observed intervention benefits was under rather ideal circumstances, and hence the study could possibly overestimate the effects when compared to usual conditions. Conclusions Handwashing with soap at key times and weekly nail clipping significantly decreased intestinal parasite reinfection rates. Furthermore, the handwashing intervention significantly reduced anemia prevalence in children. The next essential step should be implementing pragmatic studies and developing more effective approaches to promote and implement handwashing with soap and nail clipping at larger scales. PMID:26057703
Mahmud, Mahmud Abdulkader; Spigt, Mark; Bezabih, Afework Mulugeta; Pavon, Ignacio Lopez; Dinant, Geert-Jan; Velasco, Roman Blanco
2015-06-01
Intestinal parasitic infections are highly endemic among school-aged children in resource-limited settings. To lower their impact, preventive measures should be implemented that are sustainable with available resources. The aim of this study was to assess the impact of handwashing with soap and nail clipping on the prevention of intestinal parasite reinfections. In this trial, 367 parasite-negative school-aged children (aged 6-15 y) were randomly assigned to receive both, one or the other, or neither of the interventions in a 2 × 2 factorial design. Assignment sequence was concealed. After 6 mo of follow-up, stool samples were examined using direct, concentration, and Kato-Katz methods. Hemoglobin levels were determined using a HemoCue spectrometer. The primary study outcomes were prevalence of intestinal parasite reinfection and infection intensity. The secondary outcome was anemia prevalence. Analysis was by intention to treat. Main effects were adjusted for sex, age, drinking water source, latrine use, pre-treatment parasites, handwashing with soap and nail clipping at baseline, and the other factor in the additive model. Fourteen percent (95% CI: 9% to 19%) of the children in the handwashing with soap intervention group were reinfected versus 29% (95% CI: 22% to 36%) in the groups with no handwashing with soap (adjusted odds ratio [AOR] 0.32, 95% CI: 0.17 to 0.62). Similarly, 17% (95% CI: 12% to 22%) of the children in the nail clipping intervention group were reinfected versus 26% (95% CI: 20% to 32%) in the groups with no nail clipping (AOR 0.51, 95% CI: 0.27 to 0.95). Likewise, following the intervention, 13% (95% CI: 8% to 18%) of the children in the handwashing group were anemic versus 23% (95% CI: 17% to 29%) in the groups with no handwashing with soap (AOR 0.39, 95% CI: 0.20 to 0.78). The prevalence of anemia did not differ significantly between children in the nail clipping group and those in the groups with no nail clipping (AOR 0.53, 95% CI: 0.27 to 1.04). The intensive follow-up and monitoring during this study made it such that the assessment of the observed intervention benefits was under rather ideal circumstances, and hence the study could possibly overestimate the effects when compared to usual conditions. Handwashing with soap at key times and weekly nail clipping significantly decreased intestinal parasite reinfection rates. Furthermore, the handwashing intervention significantly reduced anemia prevalence in children. The next essential step should be implementing pragmatic studies and developing more effective approaches to promote and implement handwashing with soap and nail clipping at larger scales.
Video Clip of a Rover Rock-Drilling Demonstration at JPL
2013-02-20
This frame from a video clip shows moments during a demonstration of drilling into a rock at NASA JPL, Pasadena, Calif., with a test double of the Mars rover Curiosity. The drill combines hammering and rotation motions of the bit.
Our History Clips: Collaborating for the Common Good
ERIC Educational Resources Information Center
Bailey, Beatrice N.
2017-01-01
This case study reveals how middle school social studies teachers within a professional development program are encouraging their students to use multiple disciplinary literacies to create Our History Clips as they also work toward developing a classroom community of engaged student citizens.
Dündar, Tolga Turan; Aralaşmak, Ayşe; Özdemir, Hüseyin; Seyithanoğlu, Mehmet Hakan; Uysal, Ömer; Toprak, Hüseyin; Kitiş, Serkan; Özek, Erdinç; Alkan, Alpay
2017-10-18
To compare effectiveness of contrast-enhanced MRA (CE-MRA), 3D-Time-of-flight MRA (3D-TOF-MRA) and subtracted CTA from CTP (sub-CTA) in residue evaluation of intracranial aneurysms treated either with coiling or clipping. Sixteen treated aneurysms, which were evaluated with three methods within two weeks after the operation, were enrolled. The success of each imaging techniques in demonstration of residue aneurysm and nearby vessels was compared by Fisher\\'s Exact Test. The differences among three was evaluated by Cochran\\'s Q test (p ≤ 0.05). Perfusion abnormality was noted in % 81 of clipped and none of coiled patients. Vessel visualization in the vicinity of aneurysm was better in sub-CTA, followed by CE-MRA. In clipped aneurysms, sub-CTA revealed residue aneurysms in % 16,7 of the patients while 3D-TOF-MRA and CE-MRA revealed none. In coiled aneurysms, CE-MRA revealed residue aneurysms in 100 %, and TOF-MRA in 33,3 % while sub-CTA revealed none. Although dramatic differences were noted in the evaluation of residue aneurysm as well as nearby vessel visualization, no statistical significance noted due to very few patients in subcategories Conclusion: This is first study comparing the effectiveness of CE-MRA, 3D-TOF MRA and sub-CTA in residue aneurysms evaluation. Vessel visualization in the vicinity of aneurysm was better in sub-CTA in all regardless of coiling or clipping. Residue aneurysms were more commonly revealed by CE-MRA in coiled patients and more commonly and better shown by sub-CTA in clipped patients in addition of showing perfusion abnormality that's is more common in clipped patients.
Sanai, Nader; Caldwell, Nolan; Englot, Dario J; Lawton, Michael T
2012-08-01
Many neurosurgeons feel competent clipping posterior communicating artery (PCoA) aneurysms and include this lesion in their practice. However, endovascular therapy removes simple aneurysms that would have been easiest to clip with the best results. What remains are aneurysms with complex anatomy and technical challenges that are not well described. A contemporary surgical series with PCoA aneurysms is reviewed to define the patients, microsurgical techniques, and outcomes in current practice. A total of 218 patients had 218 PCoA aneurysms that were treated microsurgically during an 11-year period. Complexities influencing aneurysm management included (1) large/giant size; (2) fetal posterior cerebral artery; (3) previous coiling; (4) anterior clinoidectomy; (5) adherence of the anterior choroidal artery (AChA); (6) intraoperative aneurysm rupture; (7) complex clipping; and (8) atherosclerotic calcification. Simple PCoA aneurysms were encountered in 113 patients (51.8%) and complex aneurysms in 105 (48.2%). Adherent AChA (13.8%) and intraoperative rupture (11.5%) were the most common complexities. Simple aneurysms had favorable outcomes in 86.6% of patients, whereas aneurysms with 1 or multiple complexities had favorable outcomes in 78.2% and 75.0%, respectively. Intraoperative rupture (P < .01), large/giant size (P = .04), and complex clipping (P = .05) were associated with increased neurological worsening. Because endovascular therapy alters the surgical population, neurosurgeons should recalibrate their expectations with this once straightforward aneurysm. The current mix of PCoA aneurysms requires advanced techniques including clinoidectomy, AChA microdissection, complex clipping, and facility with intraoperative rupture. Microsurgery is recommended for recurrent aneurysms after coiling, complex branches, aneurysms causing oculomotor nerve palsy, multiple aneurysms, and patients with hematomas.
Yun, Seok Won; Kim, Yun Seok; Lee, Yongjik; Lim, Han Jung; Park, Soon Ik; Jung, Jong Pil; Park, Chang Ryul
2017-01-01
There are many ways to treat focal hyperhidrosis, including surgeries for palmar and axillary hyperhidrosis. However, doctors and patients tend to be reluctant to perform surgery for plantar hyperhidrosis due to misconceptions and prejudices about surgical treatment. In addition, few studies have reported the outcome of surgeries for plantar hyperhidrosis. Therefore, the objective of this study was to determine the outcome (early and late postoperative satisfaction, complication, compensatory hyperhidrosis, recurrence rate, and efficiency) of surgical treatment for plantar hyperhidrosis. From August 2014 to October 2015, lumbar sympathetic block (LSB) was performed in 82 patients with plantar hyperhidrosis using clipping method. Limited video-assisted LSB was performed using 5 mm ligamax-clip or 3 mm horizontal-clip after identifying L3-4 sympathetic ganglion through finger-touch and endoscopic vision. Of the 82 patients, 45 were male and 37 were female. Their mean age was 26.38 years (range, 14-51 years). Mean follow-up time was 6.60 ± 3.56 months. Mean early postoperative satisfaction score was 9.6 on the 10th day postoperative evaluation. At more than 1 month later, the mean late postoperative satisfaction score was 9.2. There was no significant difference in early postoperative satisfaction score between clipping level L3 and L4/5. However, late postoperative satisfaction score was significantly better in the L3 group than that in the L4/5 group. Patient's age and body mass index did not affect the satisfaction score. However, male patients and patients who had history of hyperhidrosis operation showed higher satisfaction score than others. Limited video-assisted LSB using clip provided good results with minimal complications and low compensatory hidrosis, contrary to the prejudice toward it. Therefore, surgical treatment is recommended for plantar hyperhidrosis.
Surgical gesture classification from video and kinematic data.
Zappella, Luca; Béjar, Benjamín; Hager, Gregory; Vidal, René
2013-10-01
Much of the existing work on automatic classification of gestures and skill in robotic surgery is based on dynamic cues (e.g., time to completion, speed, forces, torque) or kinematic data (e.g., robot trajectories and velocities). While videos could be equally or more discriminative (e.g., videos contain semantic information not present in kinematic data), they are typically not used because of the difficulties associated with automatic video interpretation. In this paper, we propose several methods for automatic surgical gesture classification from video data. We assume that the video of a surgical task (e.g., suturing) has been segmented into video clips corresponding to a single gesture (e.g., grabbing the needle, passing the needle) and propose three methods to classify the gesture of each video clip. In the first one, we model each video clip as the output of a linear dynamical system (LDS) and use metrics in the space of LDSs to classify new video clips. In the second one, we use spatio-temporal features extracted from each video clip to learn a dictionary of spatio-temporal words, and use a bag-of-features (BoF) approach to classify new video clips. In the third one, we use multiple kernel learning (MKL) to combine the LDS and BoF approaches. Since the LDS approach is also applicable to kinematic data, we also use MKL to combine both types of data in order to exploit their complementarity. Our experiments on a typical surgical training setup show that methods based on video data perform equally well, if not better, than state-of-the-art approaches based on kinematic data. In turn, the combination of both kinematic and video data outperforms any other algorithm based on one type of data alone. Copyright © 2013 Elsevier B.V. All rights reserved.
Panaich, Sidakpal S; Arora, Shilpkumar; Badheka, Apurva; Kumar, Varun; Maor, Elad; Raphael, Claire; Deshmukh, Abhishek; Reeder, Guy; Eleid, Mackram; Rihal, Charanjit S
2018-05-01
There are sparse clinical data on the procedural trends, outcomes and readmission rates following FDA approval and expansion of Transcatheter mitral valve repair/MitraClip ® . Whether a complex new technology can be disseminated safely and quickly is controversial. The study cohort was derived from the National Readmission Data (NRD) 2013-14. MitraClip ® was identified using appropriate International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM) codes. The primary outcome was a composite of in-hospital mortality + procedural complications. Secondary outcome included 30-day readmissions. Hierarchical two level logistic models were used to evaluate study outcomes. Our analysis included 2003 MitraClip ® procedures. Overall in-hospital mortality was 3.9%. As expected, there was a significant increase in procedural volume post-FDA approval. Importantly, a corresponding downward trend in mortality and procedural complications was observed. Significant predictors of in-hospital mortality and procedural complications included the use of vasopressors (P <0.001) and hemodynamic support (P < 0.001). Higher hospital volume (≥10 MitraClips/year) was associated with lower in-hospital mortality and complications (P = 0.02). There were 304 (15.1%) 30-day readmissions, with heart failure being the most common cause of readmission. Elective procedures had lower in-hospital mortality (P < 0.001) and lower readmission rates (P = 0.011) compared with nonelective procedures. A significant increase in MitraClip ® procedural volumes occurred post-FDA approval. Overall morbidity and mortality were low and trended downwards. Hospital procedure volume ≥10 cases were associated with lower mortality and overall complication rates. These data suggest a successful roll out of a very complex novel structural heart procedure. © 2017 Wiley Periodicals, Inc.
Kaiser, Jan Christian; Meckbach, Reinhard; Eidemüller, Markus; Selmansberger, Martin; Unger, Kristian; Shpak, Viktor; Blettner, Maria; Zitzelsberger, Horst; Jacob, Peter
2016-12-01
Strong evidence for the statistical association between radiation exposure and disease has been produced for thyroid cancer by epidemiological studies after the Chernobyl accident. However, limitations of the epidemiological approach in order to explore health risks especially at low doses of radiation appear obvious. Statistical fluctuations due to small case numbers dominate the uncertainty of risk estimates. Molecular radiation markers have been searched extensively to separate radiation-induced cancer cases from sporadic cases. The overexpression of the CLIP2 gene is the most promising of these markers. It was found in the majority of papillary thyroid cancers (PTCs) from young patients included in the Chernobyl tissue bank. Motivated by the CLIP2 findings we propose a mechanistic model which describes PTC development as a sequence of rate-limiting events in two distinct paths of CLIP2-associated and multistage carcinogenesis. It integrates molecular measurements of the dichotomous CLIP2 marker from 141 patients into the epidemiological risk analysis for about 13 000 subjects from the Ukrainian-American cohort which were exposed below age 19 years and were put under enhanced medical surveillance since 1998. For the first time, a radiation risk has been estimated solely from marker measurements. Cross checking with epidemiological estimates and model validation suggests that CLIP2 is a marker of high precision. CLIP2 leaves an imprint in the epidemiological incidence data which is typical for a driver gene. With the mechanistic model, we explore the impact of radiation on the molecular landscape of PTC. The model constitutes a unique interface between molecular biology and radiation epidemiology. © The Author 2016. Published by Oxford University Press.
Volder, Astrid; Gifford, Roger M.; Evans, John R.
2015-01-01
Forecasting the effects of climate change on nitrogen (N) cycling in pastures requires an understanding of changes in tissue N. We examined the effects of elevated atmospheric CO2 concentration, atmospheric warming and simulated grazing (clipping frequency) on aboveground and belowground tissue N concentrations and C : N ratios of a C3 pasture grass. Phalaris aquatica L. cv. ‘Holdfast’ was grown in the field in six transparent temperature gradient tunnels (18 × 1.5 × 1.5 m each), three at ambient atmospheric CO2 and three at 759 p.p.m. CO2. Within each tunnel, there were three air temperature treatments: ambient control, +2.2/+4.0 °C above ambient day/night warming and +3.0 °C continuous warming. A frequent and an infrequent clipping treatment were applied to each warming × CO2 combination. Green leaf N concentrations were decreased by elevated CO2 and increased by more frequent clipping. Both warming treatments increased leaf N concentrations under ambient CO2 concentrations, but did not significantly alter leaf N concentrations under elevated CO2 concentrations. Nitrogen resorption from leaves was decreased under elevated CO2 conditions as well as by more frequent clipping. Fine root N concentrations decreased strongly with increasing soil depth and were further decreased at the 10–60 cm soil depths by elevated CO2 concentrations. The interaction between the CO2 and warming treatments showed that leaf N concentration was affected in a non-additive manner. Changes in leaf C : N ratios were driven by changes in N concentration. Overall, the effects of CO2, warming and clipping treatments on aboveground tissue N concentrations were much greater than on belowground tissue. PMID:26272874
Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling.
Shen, Guangping; Zhang, Songning; Bennett, Hunter J; Martin, James C; Crouter, Scott E; Fitzhugh, Eugene C
2018-06-01
Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling.
NASA Astrophysics Data System (ADS)
Ivleva, Vera B.; Schneck, Nicole A.; Gollapudi, Deepika; Arnold, Frank; Cooper, Jonathan W.; Lei, Q. Paula
2018-05-01
CAP256 is one of the highly potent, broadly neutralizing monoclonal antibodies (bNAb) designed for HIV-1 therapy. During the process development of one of the constructs, an unexpected product-related impurity was observed via microfluidics gel electrophoresis. A panel of complementary LC-MS analyses was applied for the comprehensive characterization of CAP256 which included the analysis of the intact and reduced protein, the middle-up approach, and a set of complementary peptide mapping techniques and verification of the disulfide bonds. The designed workflow allowed to identify a clip within a protruding acidic loop in the CDR-H3 region of the heavy chain, which can lead to the decrease of bNAb potency. This characterization explained the origin of the additional species reflected by the reducing gel profile. An intra-loop disulfide bond linking the two fragments was identified, which explained why the non-reducing capillary electrophoresis (CE) profile was not affected. The extensive characterization of CAP256 post-translational modifications was performed to investigate a possible cause of CE profile complexity and to illustrate other structural details related to this molecule's biological function. Two sites of the engineered Tyr sulfation were verified in the antigen-binding loop, and pyroglutamate formation was used as a tool for monitoring the extent of antibody clipping. Overall, the comprehensive LC-MS study was crucial to (1) identify the impurity as sequence clipping, (2) pinpoint the clipping location and justify its susceptibility relative to the molecular structure, (3) lead to an upstream process optimization to mitigate product quality risk, and (4) ultimately re-engineer the sequence to be clip-resistant. [Figure not available: see fulltext.
NASA Astrophysics Data System (ADS)
Mataracioglu, M.; Magnani, M.; DeShon, H. R.; Cox, R. T.
2011-12-01
The Caribbean plate subducts beneath the North American and the South American plates at the Muertos Trough and the South Caribbean Deformed Belt (SCDB), respectively. During subduction, large amount of crustal material may enter the subduction zone with the subducting plate or may be incorporated into the accretionary prism. To investigate the changes in collisional style and structures associated with subduction of the Caribbean Large Igneous Province (CLIP) versus normal oceanic crust, we interpret seismic reflection profiles collected around the northern and southern margins of the Venezuelan Basin. We refine the extent of the CLIP in the central and eastern Caribbean by identifying the structural differences at the top of the acoustic basement (Horizon B") on a dataset of 150 multi-channel seismic time stack and migrated marine reflection profiles acquired in eight cruises from 1975 to 2004, as well as some selected Integrated Ocean Drilling Program (IODP) drilling data. We will also attempt to determine whether sedimentary material enters the trench and is recycled back into the mantle, and therefore characterize the northern and southern subduction zones as accretionary or erosive. Our preliminary results show that the CLIP extends spatially to most of the Venezuelan Basin, the western part of the Columbian Basin, and a part of the Beata Ridge, but that it does not extend as far south as suggested by previous interpretations. Furthermore, some portions of the CLIP at the northern and southern boundaries subduct beneath the North and the South American plates at the Muertos Trough and the SCDB, respectively. The change in nature of the subducting plate (CLIP or normal oceanic crust) causes variations in the collisional style (i.e., accretionary versus erosive) and in structures at the accretionary wedge and on the downgoing plate.
Carvalho, Joana; Pereira, Raquel; Barreto, Diana; Nobre, Pedro J
2017-11-01
The relationship between emotions and sexual functioning has been documented since early sex research. Among other effects, emotions are expected to impact sexual response by shaping individuals' attention to sexual cues; yet, this assumption has not been tested. This study aimed to investigate whether attentional processes to sexual cues are impacted by state emotions, and whether the processes impacted by emotions relate to subjective sexual arousal to a sex film clip. A total of 52 men and 73 women were randomly assigned to one of three experimental conditions: (1) a negative mood induction condition (sadness as dominant emotion), (2) a positive mood induction condition (amusement as dominant emotion), and a (3) neutral/control condition. After mood induction, participants were exposed to a sex film clip while their focus of visual attention was measured using an eye tracker. Three areas of interest (AOI) were considered within the sex clip: background (non-sexual cues), body interaction, and genital interaction. Self-reported attention, thoughts during the sex clip, percent dwell time, and pupil size to AOI were considered as attentional markers. Findings revealed that the attentional processes were not impacted by the mood conditions. Instead, gender effects were found. While men increased their visual attention to the background area of the film clip, women increased attention to the genital area. Also, sexual arousal thoughts during exposure to the sex clip were consistently related to subjective sexual arousal regardless of the momentary emotional state. Findings add to the literature by showing that men and women process the sexual components of a stimulus differently and by challenging the assumption that emotions shape attention to sexual cues.
Zhou, Dong-Sheng; Xu, Li; Luo, Yao-Ling; He, Feng-Ying; Huang, Jun-Ting; Zhang, Yao-Jun; Chen, Min-Shan
2015-01-01
AIM: To compare the prognostic ability of inflammation scores for patients with hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC) undergoing transarterial chemoembolization (TACE). METHODS: Data of 224 consecutive patients who underwent TACE for unresectable HBV-related HCC from September 2009 to November 2011 were retrieved from a prospective database. The association of inflammation scores with clinicopathologic variables and overall survival (OS) were analyzed, and receiver operating characteristic curves were generated, and the area under the curve (AUC) was calculated to evaluate the discriminatory ability of each inflammation score and staging system, including tumor-node-metastasis, Barcelona Clinic Liver Cancer, and Cancer of the Liver Italian Program (CLIP) scores. RESULTS: The median follow-up period was 390 d, the one-, two-, and three-year OS were 38.4%, 18.3%, and 11.1%, respectively, and the median OS was 390 d. The Glasgow Prognostic Score (GPS), modifed GPS, neutrophil-lymphocyte ratio, and Prognostic Index were associated with OS. The GPS consistently had a higher AUC value at 6 mo (0.702), 12 mo (0.676), and 24 mo (0.687) in comparison with other inflammation scores. CLIP consistently had a higher AUC value at 6 mo (0.656), 12 mo (0.711), and 24 mo (0.721) in comparison with tumor-node-metastasis and Barcelona Clinic Liver Cancer staging systems. Multivariate analysis revealed that alanine aminotransferase, GPS, and CLIP were independent prognostic factors for OS. The combination of GPS and CLIP (AUC = 0.777) was superior to CLIP or GPS alone in prognostic ability for OS. CONCLUSION: The prognostic ability of GPS is superior to other inflammation scores for HCC patients undergoing TACE. Combining GPS and CLIP improved the prognostic power for OS. PMID:25987783
DeVries, R. J.; Schramm, Harold L.
2015-01-01
We tested the hypothesis that δ13C and δ15N signatures of pectoral spines would provide measures of δ13C and δ15N similar to those obtained from fin clips for adult shovelnose sturgeon Scaphirhynchus platorynchus. Thirty-two shovelnose sturgeon (fork length [FL] = 500–724 mm) were sampled from the lower Mississippi River, USA on 23 February 2013. Isotopic relationships between the two tissue types were analyzed using mixed model analysis of covariance. Tissue types differed significantly for both δ13C (P < 0.01; spine: mean = −23.83, SD = 0.62; fin clip: mean = −25.74, SD = 0.97) and δ15N (P = 0.01; spine: mean = 17.01, SD = 0.51; fin clip: mean = 17.19, SD = 0.62). Neither FL nor the FL × tissue type interaction had significant (P > 0.05) effects on δ13C. Fin clip δ13C values were highly variable and weakly correlated (r = 0.16, P = 0.40) with those from pectoral spines. We found a significant FL-tissue type interaction for δ15N, reflecting increasing δ15N with FL for spines and decreasing δ15N with FL for fin clips. These results indicate that spines are not a substitute for fin clip tissue for measuring δ13C and δ15N for shovelnose sturgeon in the lower Mississippi River, but the two tissues have different turnover rates they may provide complementary information for assessing trophic position at different time scales.
Cross-modal enhancement of speech detection in young and older adults: does signal content matter?
Tye-Murray, Nancy; Spehar, Brent; Myerson, Joel; Sommers, Mitchell S; Hale, Sandra
2011-01-01
The purpose of the present study was to examine the effects of age and visual content on cross-modal enhancement of auditory speech detection. Visual content consisted of three clearly distinct types of visual information: an unaltered video clip of a talker's face, a low-contrast version of the same clip, and a mouth-like Lissajous figure. It was hypothesized that both young and older adults would exhibit reduced enhancement as visual content diverged from the original clip of the talker's face, but that the decrease would be greater for older participants. Nineteen young adults and 19 older adults were asked to detect a single spoken syllable (/ba/) in speech-shaped noise, and the level of the signal was adaptively varied to establish the signal-to-noise ratio (SNR) at threshold. There was an auditory-only baseline condition and three audiovisual conditions in which the syllable was accompanied by one of the three visual signals (the unaltered clip of the talker's face, the low-contrast version of that clip, or the Lissajous figure). For each audiovisual condition, the SNR at threshold was compared with the SNR at threshold for the auditory-only condition to measure the amount of cross-modal enhancement. Young adults exhibited significant cross-modal enhancement with all three types of visual stimuli, with the greatest amount of enhancement observed for the unaltered clip of the talker's face. Older adults, in contrast, exhibited significant cross-modal enhancement only with the unaltered face. Results of this study suggest that visual signal content affects cross-modal enhancement of speech detection in both young and older adults. They also support a hypothesized age-related deficit in processing low-contrast visual speech stimuli, even in older adults with normal contrast sensitivity.
Gruppen, Tonia; Smith, Molly; Ganss, Andrea
2012-01-01
In the National Athletic Trainers' Association position statement, "Acute Management of the Cervical Spine-Injured Athlete," the technique recommended for face-mask (FM) removal is one that "creates the least head and neck motion, is performed most quickly, is the least difficult, and carries the least chance of failure." Industrial and technological advances in football helmet design and FM attachment systems might influence the efficacy of emergency FM removal. To examine the removal times and success rates of the Quick Release (QR) Face Guard Attachment System (Riddell Sports, Inc, Elyria, OH) throughout and at the conclusion of 1 season of play by a National Collegiate Athletic Association Division III football team competing in the Midwest. Controlled laboratory study. College laboratory. A total of 69 randomly selected Revolution IQ (Riddell Sports, Inc) football helmets fitted with the QR system were used. Each helmet was secured to a spine board, and investigators attempted to remove both of the QR side clips from the helmet with the Riddell insertion tool. Dependent variables included total time for removal of both QR side clips from the FM and success rate for removal of both side clips. The overall success rate for removal of both clips was 94.8% (164/173), whereas the mean times for removal of both clips ranged from 9.92 ± 12.06 seconds to 16.65 ± 20.97 seconds over 4 trial sessions. We found no differences among mean times for trial sessions throughout the season of play among the same helmets or among different helmets (P > .05). Removal time and success rate of the Riddell QR were satisfactory during and after 1 season of play despite use in various temperatures and precipitation.
An SQL query generator for CLIPS
NASA Technical Reports Server (NTRS)
Snyder, James; Chirica, Laurian
1990-01-01
As expert systems become more widely used, their access to large amounts of external information becomes increasingly important. This information exists in several forms such as statistical, tabular data, knowledge gained by experts and large databases of information maintained by companies. Because many expert systems, including CLIPS, do not provide access to this external information, much of the usefulness of expert systems is left untapped. The scope of this paper is to describe a database extension for the CLIPS expert system shell. The current industry standard database language is SQL. Due to SQL standardization, large amounts of information stored on various computers, potentially at different locations, will be more easily accessible. Expert systems should be able to directly access these existing databases rather than requiring information to be re-entered into the expert system environment. The ORACLE relational database management system (RDBMS) was used to provide a database connection within the CLIPS environment. To facilitate relational database access a query generation system was developed as a CLIPS user function. The queries are entered in a CLlPS-like syntax and are passed to the query generator, which constructs and submits for execution, an SQL query to the ORACLE RDBMS. The query results are asserted as CLIPS facts. The query generator was developed primarily for use within the ICADS project (Intelligent Computer Aided Design System) currently being developed by the CAD Research Unit in the California Polytechnic State University (Cal Poly). In ICADS, there are several parallel or distributed expert systems accessing a common knowledge base of facts. Expert system has a narrow domain of interest and therefore needs only certain portions of the information. The query generator provides a common method of accessing this information and allows the expert system to specify what data is needed without specifying how to retrieve it.
Kurogi, Ryota; Kada, Akiko; Nishimura, Kunihiro; Kamitani, Satoru; Nishimura, Ataru; Sayama, Tetsuro; Nakagawara, Jyoji; Toyoda, Kazunori; Ogasawara, Kuniaki; Ono, Junichi; Shiokawa, Yoshiaki; Aruga, Toru; Miyachi, Shigeru; Nagata, Izumi; Matsuda, Shinya; Yoshimura, Shinichi; Okuchi, Kazuo; Suzuki, Akifumi; Nakamura, Fumiaki; Onozuka, Daisuke; Hagihara, Akihito; Iihara, Koji
2018-05-01
OBJECTIVE Although heterogeneity in patient outcomes following subarachnoid hemorrhage (SAH) has been observed across different centers, the relative merits of clipping and coiling for SAH remain unknown. The authors sought to compare the patient outcomes between these therapeutic modalities using a large nationwide discharge database encompassing hospitals with different comprehensive stroke center (CSC) capabilities. METHODS They analyzed data from 5214 patients with SAH (clipping 3624, coiling 1590) who had been urgently hospitalized at 393 institutions in Japan in the period from April 2012 to March 2013. In-hospital mortality, modified Rankin Scale (mRS) score, cerebral infarction, complications, hospital length of stay, and medical costs were compared between the clipping and coiling groups after adjustment for patient-level and hospital-level characteristics by using mixed-model analysis. RESULTS Patients who had undergone coiling had significantly higher in-hospital mortality (12.4% vs 8.7%, OR 1.3) and a shorter median hospital stay (32.0 vs 37.0 days, p < 0.001) than those who had undergone clipping. The respective proportions of patients discharged with mRS scores of 3-6 (46.4% and 42.9%) and median medical costs (thousands US$, 35.7 and 36.7) were not significantly different between the groups. These results remained robust after further adjustment for CSC capabilities as a hospital-related covariate. CONCLUSIONS Despite the increasing use of coiling, clipping remains the mainstay treatment for SAH. Regardless of CSC capabilities, clipping was associated with reduced in-hospital mortality, similar unfavorable functional outcomes and medical costs, and a longer hospital stay as compared with coiling in 2012 in Japan. Further study is required to determine the influence of unmeasured confounders.
Phosphorus runoff from turfgrass as affected by phosphorus fertilization and clipping management.
Bierman, Peter M; Horgan, Brian P; Rosen, Carl J; Hollman, Andrew B; Pagliari, Paulo H
2010-01-01
Phosphorus enrichment of surface water is a concern in many urban watersheds. A 3-yr study on a silt loam soil with 5% slope and high soil test P (27 mg kg(-1) Bray P1) was conducted to evaluate P fertilization and clipping management effects on P runoff from turfgrass (Poa pratensis L.) under frozen and nonfrozen conditions. Four fertilizer treatments were compared: (i) no fertilizer, (ii) nitrogen (N)+potassium (K)+0xP, (iii) N+K+1xP, and (iv) N+K+3xP. Phosphorus rates were 21.3 and 63.9 kg ha(-1) yr(-1) the first year and 7.1 and 21.3 kg ha(-1) yr(-1) the following 2 yr. Each fertilizer treatment was evaluated with clippings removed or clippings recycled back to the turf. In the first year, P runoff increased with increasing P rate and P losses were greater in runoff from frozen than nonfrozen soil. In year 2, total P runoff from the no fertilizer treatment was greater than from treatments receiving fertilizer. This was because reduced turf quality resulted in greater runoff depth from the no fertilizer treatment. In year 3, total P runoff from frozen soil and cumulative total P runoff increased with increasing P rate. Clipping management was not an important factor in any year, indicating that returning clippings does not significantly increase P runoff from turf. In the presence of N and K, P fertilization did not improve turf growth or quality in any year. Phosphorus runoff can be reduced by not applying P to high testing soils and avoiding fall applications when P is needed.
Thiarawat, Peeraphong; Jahromi, Behnam Rezai; Kozyrev, Danil A; Intarakhao, Patcharin; Teo, Mario K; Choque-Velasquez, Joham; Hernesniemi, Juha
2017-05-01
The objectives of this study were to analyze microsurgical techniques and to determine correlations between microsurgical techniques and the radiographic findings in the microneurosurgical treatment of posterior communicating artery aneurysms (PCoAAs). We retrospectively analyzed radiographic findings and videos of surgeries in 64 patients with PCoAAs who underwent microsurgical clipping by the senior author from August 2010 to 2014. From 64 aneurysms, 30 (47%) had acute subarachnoid hemorrhage (SAH) that necessitated lamina terminalis fenestration (odds ratio [OR], 67.67; P < 0.001) and Liliequist membrane fenestration (OR, 19.62; P < 0.001). The low-lying aneurysms significantly necessitated the coagulation of the dura covering the anterior clinoid process (ACP) (OR, 7.43; P = 0.003) or anterior clinoidectomy (OR, 91.0; P < 0.001). We preferred straight clips in 45 (83%) of 54 posterolateral projecting aneurysms (OR, 45.0; P < 0.001), but preferred curved clips for posteromedial projecting aneurysms (OR, 6.39; P = 0.008). The mean operative time from the brain retraction to the final clipping was 17 minutes and 43 seconds. Postoperative computed tomography angiography revealed complete occlusion of 60 (94%) aneurysms. Three (4.6%) patients with acute SAH suffered postoperative lacunar infarction. For ruptured aneurysms, lamina terminalis and Liliequist membrane fenestration are useful for additional cerebrospinal fluid drainage. For low-lying aneurysms, coagulation of the dura covering the ACP or tailored anterior clinoidectomy might be necessary for exposing the proximal aneurysm neck. Type of clips depends on the direction of projection. The microsurgical clipping of the PCoAAs can achieve good immediate complete occlusion rate with low postoperative stroke rate. Copyright © 2017 Elsevier Inc. All rights reserved.
Mori, H; Rafiq, K; Kobara, H; Fujihara, S; Nishiyama, N; Kobayashi, M; Himoto, T; Haba, R; Hagiike, M; Izuishi, K; Okano, K; Suzuki, Y; Masaki, T
2012-07-01
Endoscopic submucosal dissection (ESD) of large gastric lesions results in an extensive artificial ulcer that can lead to marked gastric deformity. The aim of the current study was to evaluate therapeutic efficacy in the prevention of gastric deformity of local triamcinolone acetonide (TCA) injection into the extensive artificial ulcer following ESD. A total of 45 patients who were diagnosed with early gastric cancer were enrolled. Patients were randomly assigned by the sealed-envelope randomization method to either local TCA injections (n = 21) or sham-control (n = 20) groups. Two clips were placed at the two maximum outer edges of the artificial ulcer after the lesion had been resected (Day 0). Local TCA injections were performed on postoperative Day 5 and Day 12. The distance between the two clips was measured by endoscopic measuring forceps on Days 5, 12, 30, and 60. Granulation formation and gastric deformity were evaluated by visual analog scale (VAS) on Days 30 and 60. Local TCA injection did not alter clip-to-clip distance on postoperative Day 60, and formation of flat granulation tissue over the ulcer was followed by regenerative mucosa without any gastric deformity. The sham-control group showed significant shortening of clip-to-clip distance compared with the local steroid-injected group and protruded forms of granulation tissue with mucosal convergence. Histological evaluation revealed prominent growth of neovessels, swelling, and marked increases in endothelial cells in the local steroid-injected group compared with the sham-control group. Local steroid injection into the floor of a post-ESD artificial ulcer promotes the formation of granulation tissue at an early stage of the healing process leading to regeneration of gastric mucosa without mucosal convergence or gastric deformity. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Technical Reports Server (NTRS)
1992-01-01
C Language Integrated Production System (CLIPS) was used by Esse Systems to develop an expert system for clients who want to automate portions of their operations. The resulting program acts as a scheduling expert and automates routine, repetitive scheduling decisions, allowing employees to spend time on more creative projects.
Clip-on wireless wearable microwave sensor for ambulatory cardiac monitoring.
Fletcher, Richard R; Kulkarni, Sarang
2010-01-01
We present a new type of non-contact sensor for use in ambulatory cardiac monitoring. The sensor operation is based on a microwave Doppler technique; however, instead of detecting the heart activity from a distance, the sensor is placed on the patient's chest over the clothing. The microwave sensor directly measures heart movement rather than electrical activity, and is thus complementary to ECG. The primary advantages of the microwave sensor includes small size, light weight, low power, low-cost, and the ability to operate through clothing. We present a sample sensor design that incorporates a 2.4 GHz Doppler circuit, integrated microstrip patch antenna, and microntroller with 12-bit ADC data sampling. The prototype sensor also includes a wireless data link for sending data to a remote PC or mobile phone. Sample data is shown for several subjects and compared to data from a commercial portable ECG device. Data collected from the microwave sensor exhibits a significant amount of features, indicating possible use as a tool for monitoring heart mechanics and detection of abnormalities such as fibrillation and akinesia.
Qiu, Hongyan; Li, Li; Wu, Shangchun; Liang, Hong; Yuan, Wei; He, Yingqin
2011-03-01
To compare the specific effects of 2 female sterilization methods: the modified Uchida technique and the application of silver clips. A total of 2198 women living in rural areas who were still of reproductive age but opting for sterilization were enrolled. The participants were randomly divided into 2 groups, and underwent sterilization by either modified Uchida technique or silver clips. Information on acceptability, operation conditions, effectiveness, adverse effects, and complaints was collected 3, 6, and 12 months after the procedure. No significant difference in effectiveness, adverse effects or chief complaints between the 2 procedures was found. Differences in operative outcome, bleeding volume during the procedure, and operation time were found. A shorter operation time and less bleeding for the silver clip method indicated that female sterilization by this technique was as safe as that by modified Uchida technique. Copyright © 2010 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Decision blocks: A tool for automating decision making in CLIPS
NASA Technical Reports Server (NTRS)
Eick, Christoph F.; Mehta, Nikhil N.
1991-01-01
The human capability of making complex decision is one of the most fascinating facets of human intelligence, especially if vague, judgemental, default or uncertain knowledge is involved. Unfortunately, most existing rule based forward chaining languages are not very suitable to simulate this aspect of human intelligence, because of their lack of support for approximate reasoning techniques needed for this task, and due to the lack of specific constructs to facilitate the coding of frequently reoccurring decision block to provide better support for the design and implementation of rule based decision support systems. A language called BIRBAL, which is defined on the top of CLIPS, for the specification of decision blocks, is introduced. Empirical experiments involving the comparison of the length of CLIPS program with the corresponding BIRBAL program for three different applications are surveyed. The results of these experiments suggest that for decision making intensive applications, a CLIPS program tends to be about three times longer than the corresponding BIRBAL program.
Einstein in Hollywood: Capturing the Scientific Minds of Movie Buffs
NASA Astrophysics Data System (ADS)
Young, Chadwick
2010-10-01
The film industry captures the minds of most students today. Americans spend one-half of their leisure time watching television, and students may often neglect their studies to catch the latest episode of Desperate Housewives or the new release of Leatherheads. Science teachers are challenged to compete with these seemingly unconquerable forces. One alternative to battling the influence of multimedia in its onslaught against the scientific minds of our youth is to embrace these monsters and tame them. By relating what the students know best (who kissed who in Walk the Line) with what they know least (thermodynamics, e.g.), teachers form connections in the minds of their students that will last for many years. In this session, the presenter will demonstrate an inquiry-based method employing clips from popular movies to learn physics. He will show movie clips from several different areas of physics, examine the particular clips in light of those physical principles, and discuss how to use the clips in the classroom.
Light, Sharee N; Moran, Zachary D; Swander, Lena; Le, Van; Cage, Brandi; Burghy, Cory; Westbrook, Cecilia; Greishar, Larry; Davidson, Richard J
2015-01-01
The relation between empathy subtypes and prosocial behavior was investigated in a sample of healthy adults. "Empathic concern" and "empathic happiness", defined as negative and positive vicarious emotion (respectively) combined with an other-oriented feeling of "goodwill" (i.e. a thought to do good to others/see others happy), were elicited in 68 adult participants who watched video clips extracted from the television show Extreme Makeover: Home Edition. Prosocial behavior was quantified via performance on a non-monetary altruistic decision-making task involving book selection and donation. Empathic concern and empathic happiness were measured via self-report (immediately following each video clip) and via facial electromyography recorded from corrugator (active during frowning) and zygomatic (active during smiling) facial regions. Facial electromyographic signs of (a) empathic concern (i.e. frowning) during sad video clips, and (b) empathic happiness (i.e. smiling) during happy video clips, predicted increased prosocial behavior in the form of increased goodwill-themed book selection/donation. Copyright © 2014 Elsevier B.V. All rights reserved.
Light, Sharee N.; Moran, Zachary D.; Swander, Lena; Le, Van; Cage, Brandi; Burghy, Cory; Westbrook, Cecilia; Greishar, Larry; Davidson, Richard J.
2016-01-01
The relation between empathy subtypes and prosocial behavior was investigated in a sample of healthy adults. "Empathic concern" and "empathic happiness," defined as negative and positive vicarious emotion (respectively) combined with an other-oriented feeling of “goodwill” (i.e. a thought to do good to others/see others happy), were elicited in 68 adult participants who watched video clips extracted from the television show Extreme Makeover: Home Edition. Prosocial behavior was quantified via performance on a non-monetary altruistic decision-making task involving book selection and donation. Empathic concern and empathic happiness were measured via self-report (immediately following each video clip) and via facial electromyography recorded from corrugator (active during frowning) and zygomatic (active during smiling) facial regions. Facial electromyographic signs of (a) empathic concern (i.e. frowning) during sad video clips, and (b) empathic happiness (i.e. smiling) during happy video clips, predicted increased prosocial behavior in the form of increased goodwill-themed book selection/donation. PMID:25486408
Pulse-train Stimulation of Primary Somatosensory Cortex Blocks Pain Perception in Tail Clip Test
Lee, Soohyun; Hwang, Eunjin; Lee, Dongmyeong
2017-01-01
Human studies of brain stimulation have demonstrated modulatory effects on the perception of pain. However, whether the primary somatosensory cortical activity is associated with antinociceptive responses remains unknown. Therefore, we examined the antinociceptive effects of neuronal activity evoked by optogenetic stimulation of primary somatosensory cortex. Optogenetic transgenic mice were subjected to continuous or pulse-train optogenetic stimulation of the primary somatosensory cortex at frequencies of 15, 30, and 40 Hz, during a tail clip test. Reaction time was measured using a digital high-speed video camera. Pulse-train optogenetic stimulation of primary somatosensory cortex showed a delayed pain response with respect to a tail clip, whereas no significant change in reaction time was observed with continuous stimulation. In response to the pulse-train stimulation, video monitoring and local field potential recording revealed associated paw movement and sensorimotor rhythms, respectively. Our results show that optogenetic stimulation of primary somatosensory cortex at beta and gamma frequencies blocks transmission of pain signals in tail clip test. PMID:28442945
Object oriented development of engineering software using CLIPS
NASA Technical Reports Server (NTRS)
Yoon, C. John
1991-01-01
Engineering applications involve numeric complexity and manipulations of a large amount of data. Traditionally, numeric computation has been the concern in developing an engineering software. As engineering application software became larger and more complex, management of resources such as data, rather than the numeric complexity, has become the major software design problem. Object oriented design and implementation methodologies can improve the reliability, flexibility, and maintainability of the resulting software; however, some tasks are better solved with the traditional procedural paradigm. The C Language Integrated Production System (CLIPS), with deffunction and defgeneric constructs, supports the procedural paradigm. The natural blending of object oriented and procedural paradigms has been cited as the reason for the popularity of the C++ language. The CLIPS Object Oriented Language's (COOL) object oriented features are more versatile than C++'s. A software design methodology based on object oriented and procedural approaches appropriate for engineering software, and to be implemented in CLIPS was outlined. A method for sensor placement for Space Station Freedom is being implemented in COOL as a sample problem.
Bocher, M; Chisin, R; Parag, Y; Freedman, N; Meir Weil, Y; Lester, H; Mishani, E; Bonne, O
2001-07-01
This study attempted to use PET and 15O-H2O to measure changes in regional cerebral blood flow (rCBF) during sexual arousal evoked in 10 young heterosexual males while they watched a pornographic video clip, featuring heterosexual intercourse. This condition was compared with other mental setups evoked by noisy, nature, and talkshow audiovisual clips. Immediately after each clip, the participants answered three questions pertaining to what extent they thought about sex, felt aroused, and sensed an erection. They scored their answers using a 1 to 10 scale. SPM was used for data analysis. Sexual arousal was mainly associated with activation of bilateral, predominantly right, inferoposterior extrastriate cortices, of the right inferolateral prefrontal cortex and of the midbrain. The significance of those findings is discussed in the light of current theories concerning selective attention, "mind reading" and mirroring, reinforcement of pleasurable stimuli, and penile erection.
Performance Evaluation and Community Application of Low-Cost Sensors for Ozone and Nitrogen Dioxide.
Duvall, Rachelle M; Long, Russell W; Beaver, Melinda R; Kronmiller, Keith G; Wheeler, Michael L; Szykman, James J
2016-10-13
This study reports on the performance of electrochemical-based low-cost sensors and their use in a community application. CairClip sensors were collocated with federal reference and equivalent methods and operated in a network of sites by citizen scientists (community members) in Houston, Texas and Denver, Colorado, under the umbrella of the NASA-led DISCOVER-AQ Earth Venture Mission. Measurements were focused on ozone (O₃) and nitrogen dioxide (NO₂). The performance evaluation showed that the CairClip O₃/NO₂ sensor provided a consistent measurement response to that of reference monitors (r² = 0.79 in Houston; r² = 0.72 in Denver) whereas the CairClip NO₂ sensor measurements showed no agreement to reference measurements. The CairClip O₃/NO₂ sensor data from the citizen science sites compared favorably to measurements at nearby reference monitoring sites. This study provides important information on data quality from low-cost sensor technologies and is one of few studies that reports sensor data collected directly by citizen scientists.
A better way of fitting clips? A comparative study with respect to physical workload.
Gaudez, Clarisse; Wild, Pascal; Aublet-Cuvelier, Agnès
2015-11-01
The clip fitting task is a frequently encountered assembly operation in the car industry. It can cause upper limb pain. During task laboratory simulations, upper limb muscular activity and external force were compared for 4 clip fitting methods: with the bare hand, with an unpowered tool commonly used at a company and with unpowered and powered prototype tools. None of the 4 fitting methods studied induced a lower overall workload than the other three. Muscle activity was lower at the dominant limb when using the unpowered tools and at the non-dominant limb with the bare hand or with the powered tool. Fitting clips with the bare hand required a higher external force than fitting with the three tools. Evaluation of physical workload was different depending on whether external force or muscle activity results were considered. Measuring external force only, as recommended in several standards, is insufficient for evaluating physical workload. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Budak, Gungor; Srivastava, Rajneesh; Janga, Sarath Chandra
2017-06-01
RNA-binding proteins (RBPs) control the regulation of gene expression in eukaryotic genomes at post-transcriptional level by binding to their cognate RNAs. Although several variants of CLIP (crosslinking and immunoprecipitation) protocols are currently available to study the global protein-RNA interaction landscape at single-nucleotide resolution in a cell, currently there are very few tools that can facilitate understanding and dissecting the functional associations of RBPs from the resulting binding maps. Here, we present Seten, a web-based and command line tool, which can identify and compare processes, phenotypes, and diseases associated with RBPs from condition-specific CLIP-seq profiles. Seten uses BED files resulting from most peak calling algorithms, which include scores reflecting the extent of binding of an RBP on the target transcript, to provide both traditional functional enrichment as well as gene set enrichment results for a number of gene set collections including BioCarta, KEGG, Reactome, Gene Ontology (GO), Human Phenotype Ontology (HPO), and MalaCards Disease Ontology for several organisms including fruit fly, human, mouse, rat, worm, and yeast. It also provides an option to dynamically compare the associated gene sets across data sets as bubble charts, to facilitate comparative analysis. Benchmarking of Seten using eCLIP data for IGF2BP1, SRSF7, and PTBP1 against their corresponding CRISPR RNA-seq in K562 cells as well as randomized negative controls, demonstrated that its gene set enrichment method outperforms functional enrichment, with scores significantly contributing to the discovery of true annotations. Comparative performance analysis using these CRISPR control data sets revealed significantly higher precision and comparable recall to that observed using ChIP-Enrich. Seten's web interface currently provides precomputed results for about 200 CLIP-seq data sets and both command line as well as web interfaces can be used to analyze CLIP-seq data sets. We highlight several examples to show the utility of Seten for rapid profiling of various CLIP-seq data sets. Seten is available on http://www.iupui.edu/∼sysbio/seten/. © 2017 Budak et al.; Published by Cold Spring Harbor Laboratory Press for the RNA Society.
Toprak, Cuneyt; Kahveci, Gokhan; Kilicgedik, Alev; Pala, Selcuk; Kirma, Cevat; Tabakci, Mehmet Mustafa; Inanir, Mehmet; Esen, Ali Metin
2016-10-01
The goal of this study was to determine changes in left atrial (LA) function with two-dimensional speckle tracking echocardiography (2DSTE) and real-time full-volume three-dimensional echocardiography (RT3DE) after percutaneous mitral valve repair with the MitraClip system. Furthermore, we investigated whether baseline and/or changes in LA function after MitraClip repair had any impact on prognosis. A total of 25 consecutive patients (age: 57±12 years, 76% male) with moderate-to-severe or severe mitral regurgitation (MR) were included. Patients underwent 2DSTE and RT3DE before the clip implantation and after the 12-month follow-up. Prognostic data were also recorded via the use of telephone calls and follow-up visits for 12 months after the procedure. Compared with the baseline, the LA reservoir strain (LA-Res) (7.66±4.3% vs 11.15±7.5%, P<.001) and LA contraction strain (LA-Pump) (4.64±4.3% vs 7.63±5.8%, P=.001) improved significantly after MitraClip repair; significant improvements were also seen in three-dimensional (3D) minimum LA volume index (LAV min) and maximum LA volume index (LAV max). On the other hand, conventional LA indices did not change. In total, eleven major adverse cardiac events (MACE) were observed at the 1-year follow-up. In univariate analyses, the preprocedural echocardiographic parameters that were associated with the MACE within 1 year after MitraClip repair were 3D-LAV min and LA-Res. Furthermore, these indices significantly correlated with improved functional parameters and MR reduction. In conclusion, a successful MitraClip procedure can reverse the process of LA remodeling within 12 months, and this can be detected by 2DSTE and RT3DE. Also, patients with preprocedural lower LA-Res and higher 3D-LAV min had the worst prognoses at the 1-year follow-up. © 2016, Wiley Periodicals, Inc.
Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling
Shen, Guangping; Zhang, Songning; Bennett, Hunter J.; Martin, James C.; Crouter, Scott E.; Fitzhugh, Eugene C.
2018-01-01
Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling. Key points Varus or valgus alignment did not cause increased frontal-plane knee joint loading, suggesting stationary cycling is a safe exercise. This study supports that using a toe clip did not lead to abnormal frontal-plane knee loading during stationary cycling. Two different knee frontal plane loading patterns, knee abduction and adduction moment, were observed during stationary cycling, which are likely affected by the type of knee alignment. PMID:29769833
Delibegović, Samir; Mehmedovic, Zlatan
2018-05-01
During laparoscopic appendectomy, the base of the appendix is usually secured by loop ligature or stapling device. Hem-o-lok and DS clips have been shown as alternative techniques. The aim of this study was to compare the clinical outcomes of various forms of securing the base of the appendix, in order to find the most suitable method. The study included 120 patients with acute appendicitis randomly divided into four groups with 30 patients in each. In the first group, the base of the appendix was secured using an Endoloop, in the second group using a stapling device, in the third group using Hem-o-lok, and in the fourth group using a DS clip. The primary outcome was overall morbidity following securing the base of the appendix. Secondary outcomes were time of application and operative procedure, total length of stay, and surgical outcome. No morbidity was recorded in any group. The time of application was significantly longer in the Endoloop group than in the Stapler (P < 0.0001), Hem-o-lok (P < 0.0001), and DS clips (P < 0.0001) groups. The time of application in the Stapler group was significantly shorter than in the Hem-o-lok (P < 0.0001) and the DS clips (P < 0.0001) groups. The time of the operative procedure was significantly longer in the Endoloop than in the Stapler group (P < 0.0001). The time of the operative procedure in the Stapler group was significantly shorter than in the DS clips group (P < 0.0001) but did not differ significantly from the Hem-o-lok group (P = 0.199). The time of the operative procedure in the Hem-o-lok group was significantly shorter than in the DS clips group (P = 0.044). All forms of closure of the appendix base are acceptable, but Hem-o-lok and DS clips have the best potential for further development, and will probably become the method of choice in securing the base of the appendix.
Audiological comparison between two different clips prostheses in stapes surgery.
Potena, M; Portmann, D; Guindi, S
2015-01-01
To compare audiometric results and complications of stapes surgery with two different types of piston prosthesis, the Portmann Clip Piston (Medtronic) (PCP) and the Soft Clip Piston (Kurz) (SCP). Study conducted on 64 patients who underwent primary stapedotomy from 2008 to 2011. We matched for each case of stapedotomy with the PCP (Medtronic Xomed Inc. Portmann Clip Piston Stainless Steel/Fluoroplastic) a case with the SCP (Heinz Kurz GmbH Medizintechnik Soft Piston Clip Titanium). Each group consisted of 32 patients, and patients in both groups were matched with respect to gender, age, bilateral or unilateral otosclerosis, otological symptoms (tinnitus, vertigo or dizziness), family history, operated side and the Portmann grading for otosclerosis. The length of the prosthesis used was reported. Post-operative complications such as tinnitus, vertigo, hearing loss and altered taste were documented. Each patient was subjected to a preoperative and postoperative audiogram (follow-up at the second month after the surgery). We used the Student test for statistical analysis. Statistical significance was set at < 0.01. None of the patients experienced a post-operative hearing loss and none required a later revision surgery. No statistically significant difference was found between the two populations regarding demographic data (age, sex, side, bilaterality, family history, stage and lenght of piston) and hearing level (> 0.01) in the air, bone conduction and air-bone gap (ABG). Postoperative complications did not result to be significantly different between the two groups. Also, both groups showed a significant improvement (< 0.01) in the post-operative air, bone conduction and air-bone gap. There was no statistically significant difference (> 0.01) between the post-operative hearing results (bone conduction, air conduction, air-bone gap) using the two pistons. The mean ABG improvement was respectively 16.63 dB in the SCP group and 20.59 dB in the PCP group. The titanium Soft clip piston (SCP) is a good alternative to the Portmann clip piston (PCP). Nevertheless there are some differences in the surgical fixing of these two pistons in the correct position.
NASA Astrophysics Data System (ADS)
Marlowe, Robert Lloyd
The dynamic light scattering technique of photon correlation spectroscopy has been used to investigate the dependence of the mutual diffusion coefficient of a macromolecular system upon concentration. The first part of the research was devoted to the design and construction of a single-clipping autocorrelator based on newly-developed integrated circuits. The resulting 128 channel instrument can perform real time autocorrelation for sample time intervals >(, )10 (mu)s, and batch processed autocorrelation for intervals down to 3 (mu)s. An improved design for a newer, all-digital autocorrelator is given. Homodyne light scattering experiments were then undertaken on monodisperse solutions of polystyrene spheres. The single-mode TEM(,oo) beam of an argon-ion laser ((lamda) = 5145 (ANGSTROM)) was used as the light source; all solutions were studied at room temperature. The scattering angle was varied from 30(DEGREES) to 110(DEGREES). Excellent agreement with the manufacturer's specification for the particle size was obtained from the photon correlation studies. Finally, aqueous solutions of the globular protein ovalbumin, ranging in concentration from 18.9 to 244.3 mg/ml, were illuminated under the same conditions of temperature and wavelength as before; the homodyne scattered light was detected at a fixed scattering angle of 30(DEGREES). The single-clipped photocount autocorrelation function was analyzed using the homodyne exponential integral method of Meneely et al. The resulting diffusion coefficients showed a general linear dependence upon concentration, as predicted by the generalized Stokes-Einstein equation. However, a clear peak in the data was evident at c (TURNEQ) 100 mg/ml, which could not be explained on the basis of a non -interacting particle theory. A semi-quantitative approach based on the Debye-Huckel theory of electrostatic interactions is suggested as the probable cause for the peak's rise, and an excluded volume effect for its decline.
YUCSA: A CLIPS expert database system to monitor academic performance
NASA Technical Reports Server (NTRS)
Toptsis, Anestis A.; Ho, Frankie; Leindekar, Milton; Foon, Debra Low; Carbonaro, Mike
1991-01-01
The York University CLIPS Student Administrator (YUCSA), an expert database system implemented in C Language Integrated Processing System (CLIPS), for monitoring the academic performance of undergraduate students at York University, is discussed. The expert system component in the system has already been implemented for two major departments, and it is under testing and enhancement for more departments. Also, more elaborate user interfaces are under development. We describe the design and implementation of the system, problems encountered, and immediate future plans. The system has excellent maintainability and it is very efficient, taking less than one minute to complete an assessment of one student.
Gafoor, Sameer; Petrescu, O Madalina; Lehr, Eric J; Puls, Charles; Zhang, Ming; Petersen, John L; Olsen, John V; Penev, Irina; Agrawal, Mayank; Sharma, Rahul; Barnhart, Glenn
2017-03-01
Patients who present with both severe mitral and tricuspid regurgitation who are symptomatic despite optimal medical therapy and at prohibitive risk for surgery pose a significant therapeutic challenge. The MitraClip device (Abbott Vascular) is approved for percutaneous mitral valve repair in high-risk and non-operative patients, and has also been used for tricuspid valve repair. Imaging support for percutaneous edge-to-edge tricuspid valve repair has not been reported and is a vital part of the procedure. Here, we present a periprocedural imaging strategy for percutaneous tricuspid valve repair with the MitraClip device using a bicuspidization technique.
Knowledge based translation and problem solving in an intelligent individualized instruction system
NASA Technical Reports Server (NTRS)
Jung, Namho; Biegel, John E.
1994-01-01
An Intelligent Individualized Instruction I(sup 3) system is being built to provide computerized instruction. We present the roles of a translator and a problem solver in an intelligent computer system. The modular design of the system provides for easier development and allows for future expansion and maintenance. CLIPS modules and classes are utilized for the purpose of the modular design and inter module communications. CLIPS facts and rules are used to represent the system components and the knowledge base. CLIPS provides an inferencing mechanism to allow the I(sup 3) system to solve problems presented to it in English.
7 CFR 301.75-4 - Quarantined areas.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Grass, tree, and plant clippings may be moved intrastate from the quarantined area for disposal in a...)(1) of this section, (B) The grass, tree, or plant clippings are completely covered during the... regulated plant and regulated tree, except indoor houseplants and regulated plants and regulated trees at...
FuzzyCLIPS from research to product
NASA Technical Reports Server (NTRS)
Bochsler, Dan; Dohmann, Edgar
1994-01-01
This paper describes the commercial productization of FuzzyCLIPS which was developed under a NASA Phase 2 SBIR contract. The intent of this paper is to provide a general roadmap of the processes that are required to make a viable, marketable product once its concept and development are complete.
Storms and Water Usage; Swine Flu
ERIC Educational Resources Information Center
Edwards, C. C.; Muttiah, Daniel
2009-01-01
This article offers a contemporary, authentic application of quantitative reasoning based on media clips. Students analyze items from the media to answer mathematical questions related to the article. Volumes, economics, and growth rates of a pandemic are featured in the two clips presented. (Contains 4 figures and 1 table.)
Effect of Toe Clips During Bicycle Ergometry on VO2 max.
ERIC Educational Resources Information Center
Moffat, Roger S.; Sparling, Phillip B.
1985-01-01
Eight men participated in three randomized maximal oxygen uptake tests to investigate the hypothesis that the use of toe clips on bicycle ergometers produced a higher VO2 max. No significant difference in mean VO2 max or performance time was observed. (Author/MT)
40 CFR 60.1440 - What is yard waste?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false What is yard waste? 60.1440 Section 60.1440 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED....1440 What is yard waste? Yard waste is grass, grass clippings, bushes, shrubs, and clippings from...
40 CFR 60.1440 - What is yard waste?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false What is yard waste? 60.1440 Section 60.1440 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED....1440 What is yard waste? Yard waste is grass, grass clippings, bushes, shrubs, and clippings from...
Bex, Peter J; Woods, Russell L
2013-01-01
Background Crowdsourcing has become a valuable method for collecting medical research data. This approach, recruiting through open calls on the Web, is particularly useful for assembling large normative datasets. However, it is not known how natural language datasets collected over the Web differ from those collected under controlled laboratory conditions. Objective To compare the natural language responses obtained from a crowdsourced sample of participants with responses collected in a conventional laboratory setting from participants recruited according to specific age and gender criteria. Methods We collected natural language descriptions of 200 half-minute movie clips, from Amazon Mechanical Turk workers (crowdsourced) and 60 participants recruited from the community (lab-sourced). Crowdsourced participants responded to as many clips as they wanted and typed their responses, whereas lab-sourced participants gave spoken responses to 40 clips, and their responses were transcribed. The content of the responses was evaluated using a take-one-out procedure, which compared responses to other responses to the same clip and to other clips, with a comparison of the average number of shared words. Results In contrast to the 13 months of recruiting that was required to collect normative data from 60 lab-sourced participants (with specific demographic characteristics), only 34 days were needed to collect normative data from 99 crowdsourced participants (contributing a median of 22 responses). The majority of crowdsourced workers were female, and the median age was 35 years, lower than the lab-sourced median of 62 years but similar to the median age of the US population. The responses contributed by the crowdsourced participants were longer on average, that is, 33 words compared to 28 words (P<.001), and they used a less varied vocabulary. However, there was strong similarity in the words used to describe a particular clip between the two datasets, as a cross-dataset count of shared words showed (P<.001). Within both datasets, responses contained substantial relevant content, with more words in common with responses to the same clip than to other clips (P<.001). There was evidence that responses from female and older crowdsourced participants had more shared words (P=.004 and .01 respectively), whereas younger participants had higher numbers of shared words in the lab-sourced population (P=.01). Conclusions Crowdsourcing is an effective approach to quickly and economically collect a large reliable dataset of normative natural language responses. PMID:23689038
Optimizing Sampling Efficiency for Biomass Estimation Across NEON Domains
NASA Astrophysics Data System (ADS)
Abercrombie, H. H.; Meier, C. L.; Spencer, J. J.
2013-12-01
Over the course of 30 years, the National Ecological Observatory Network (NEON) will measure plant biomass and productivity across the U.S. to enable an understanding of terrestrial carbon cycle responses to ecosystem change drivers. Over the next several years, prior to operational sampling at a site, NEON will complete construction and characterization phases during which a limited amount of sampling will be done at each site to inform sampling designs, and guide standardization of data collection across all sites. Sampling biomass in 60+ sites distributed among 20 different eco-climatic domains poses major logistical and budgetary challenges. Traditional biomass sampling methods such as clip harvesting and direct measurements of Leaf Area Index (LAI) involve collecting and processing plant samples, and are time and labor intensive. Possible alternatives include using indirect sampling methods for estimating LAI such as digital hemispherical photography (DHP) or using a LI-COR 2200 Plant Canopy Analyzer. These LAI estimations can then be used as a proxy for biomass. The biomass estimates calculated can then inform the clip harvest sampling design during NEON operations, optimizing both sample size and number so that standardized uncertainty limits can be achieved with a minimum amount of sampling effort. In 2011, LAI and clip harvest data were collected from co-located sampling points at the Central Plains Experimental Range located in northern Colorado, a short grass steppe ecosystem that is the NEON Domain 10 core site. LAI was measured with a LI-COR 2200 Plant Canopy Analyzer. The layout of the sampling design included four, 300 meter transects, with clip harvests plots spaced every 50m, and LAI sub-transects spaced every 10m. LAI was measured at four points along 6m sub-transects running perpendicular to the 300m transect. Clip harvest plots were co-located 4m from corresponding LAI transects, and had dimensions of 0.1m by 2m. We conducted regression analyses with LAI and clip harvest data to determine whether LAI can be used as a suitable proxy for aboveground standing biomass. We also compared optimal sample sizes derived from LAI data, and clip-harvest data from two different size clip harvest areas (0.1m by 1m vs. 0.1m by 2m). Sample sizes were calculated in order to estimate the mean to within a standardized level of uncertainty that will be used to guide sampling effort across all vegetation types (i.e. estimated within × 10% with 95% confidence). Finally, we employed a Semivariogram approach to determine optimal sample size and spacing.
Zhang, Daimeng; Wan, Weisong; Kong, Tongtong; Zhang, Ming; Aweya, Jude Juventus; Gong, Yi; Li, Shengkang
2018-05-07
The clip domain serine proteinases (clip-SPs) play vital roles in embryonic development and in various innate immune functions in invertebrates such as antimicrobial activity, cell adhesion, hemolymph clotting, pattern recognition and regulation of the prophenoloxidase system. However, little is known about the role of the clip domain serine proteinase in Scylla paramamosain (designated SpcSP) immunity. In the present study, we cloned a clip-SP from S. paramamosain hemocytes using rapid amplification of cDNA end (RACE) approach. The full-length cDNA of SpcSP was 1823 bp, containing a 5' untranslated region (UTR) of 334 bp, an open reading frame of 1122 bp, and a 3' UTR of 367 bp. The open reading frame encoded a polypeptide of 373 amino acids with a calculated molecular weight of 39.7 kDa and an isoelectric point of 6.64. Structurally, SpcSP has a predicted 21-residue signal peptide and possessed the characteristic features of the clip domain family of serine proteases, namely one clip domain in the amino-terminal with six highly conserved cysteine residues and one enzyme active serine proteinase domain in the carboxyl-terminal with a highly conserved catalytic triad (His 156 , Asp 226 , Ser 321 ). Phylogenetic analysis showed that SpcSP was clustered together with PtcSP (clip domain serine proteinase from Portunus trituberculatus). Quantitative real-time PCR (qPCR) analysis showed that the mRNA of SpcSP was constitutively expressed at different levels in all tested tissues in untreated S. paramamosain, with hemocytes and skin expressing the most. The transcriptional level of SpcSP in hemocytes was significantly up-regulated upon challenge with V. parahaemolyticus and LPS, indicating its involvement in antibacterial immune response. Indirect immunofluorescence analysis showed that SpcSP was expressed in the cytoplasm of all three hemocyte cell types (hyaline, semigranular and granular cells). Further, recombinant SpcSP protein exhibited strong binding ability and has antimicrobial activity against both Gram-positive and Gram-negative bacteria as well as fungi. Moreover, knockdown of SpcSP resulted in increased hemolymph clotting time and decreased the mRNA expression of SpproPO mRNA in hemocytes. These findings therefore suggest that SpcSP plays an important role in the antimicrobial defense mechanism of S. paramamosain by regulating the expression of SpproPO and hemolymph clotting in S. paramamosain. Copyright © 2018. Published by Elsevier Ltd.
Choi, Won Jung; Moon, Jin-Hee; Min, Jae Seok; Song, Yong Keun; Lee, Seung A; Ahn, Jin Woo; Lee, Sang Hun; Jung, Ha Chul
2018-03-01
During minimally invasive surgery (MIS), it is impossible to directly detect marked clips around tumors via palpation. Therefore, we developed a novel method and device using Radio Frequency IDentification (RFID) technology to detect the position of clips during minimally invasive gastrectomy or colectomy. The feasibility of the RFID-based detection system was evaluated in an animal experiment consisting of seven swine. The primary outcome was to successfully detect the location of RFID clips in the stomach and colon. The secondary outcome measures were to detect time (time during the intracorporeal detection of the RFID clip), and accuracy (distance between the RFID clip and the detected site). A total of 25 detection attempts (14 in the stomach and 11 in the colon) using the RFID antenna had a 100% success rate. The median detection time was 32.5 s (range, 15-119 s) for the stomach and 28.0 s (range, 8-87 s) for the colon. The median detection distance was 6.5 mm (range, 4-18 mm) for the stomach and 6.0 mm (range, 3-13 mm) for the colon. We demonstrated favorable results for a RFID system that detects the position of gastric and colon tumors in real-time during MIS. © 2017 Wiley Periodicals, Inc.
Spanos, William C; Brookes, James T; Smith, Mark C; Burkhart, Harold M; Bell, Edward F; Smith, Richard J H
2009-10-01
We investigated risk factors associated with unilateral iatrogenic vocal fold paralysis (IVFP) in the context of ligation of patent ductus arteriosus (PDA) and compared the rates of paralysis between vascular clip and suture ligation procedures. We performed a prospective examination of infants with isolated PDA treated surgically during 1995 to 2005. Statistical significance was determined with a 2-tailed t-test. Of 68 PDA ligations, 13 cases of left-sided IVFP were diagnosed, for an overall incidence of 19%. All cases of IVFP occurred in 55 infants who weighed less than 1 kg at birth. Suture ligature was used in 60% of all PDA ligation patients, and vascular clips in 40%. The incidence of IVFP in patients with vascular clips (19%) was similar to the incidence in those with suture ligature (20%). Hoarseness or stridor was present in 69% of patients with IVFP, compared to 17% of normal controls (p <0.001). The rate of aspiration was not increased in the IVFP group; however, 15% of the patients with IVFP had episodes of decreased oxygen saturation, versus 7% of infants with normal vocal fold mobility. A hoarse infant with a birth weight of less than 1 kg who has undergone PDA ligation should be examined for unilateral IVFP. Vascular clips and suture ligature are associated with similar rates of IVFP.
Discrimination of emotional states from scalp- and intracranial EEG using multiscale Rényi entropy.
Tonoyan, Yelena; Chanwimalueang, Theerasak; Mandic, Danilo P; Van Hulle, Marc M
2017-01-01
A data-adaptive, multiscale version of Rényi's quadratic entropy (RQE) is introduced for emotional state discrimination from EEG recordings. The algorithm is applied to scalp EEG recordings of 30 participants watching 4 emotionally-charged video clips taken from a validated public database. Krippendorff's inter-rater statistic reveals that multiscale RQE of the mid-frontal scalp electrodes best discriminates between five emotional states. Multiscale RQE is also applied to joint scalp EEG, amygdala- and occipital pole intracranial recordings of an implanted patient watching a neutral and an emotionally charged video clip. Unlike for the neutral video clip, the RQEs of the mid-frontal scalp electrodes and the amygdala-implanted electrodes are observed to coincide in the time range where the crux of the emotionally-charged video clip is revealed. In addition, also during this time range, phase synchrony between the amygdala and mid-frontal recordings is maximal, as well as our 30 participants' inter-rater agreement on the same video clip. A source reconstruction exercise using intracranial recordings supports our assertion that amygdala could contribute to mid-frontal scalp EEG. On the contrary, no such contribution was observed for the occipital pole's intracranial recordings. Our results suggest that emotional states discriminated from mid-frontal scalp EEG are likely to be mirrored by differences in amygdala activations in particular when recorded in response to emotionally-charged scenes.