Sample records for closure evaluation system

  1. Evaluation of Container Closure System Integrity for Frozen Storage Drug Products.

    PubMed

    Nieto, Alejandra; Roehl, Holger; Brown, Helen; Nikoloff, Jonas; Adler, Michael; Mahler, Hanns-Christian

    2016-01-01

    Sometimes, drug product for parenteral administration is stored in a frozen state (e.g., -20 °C or -80 °C), particularly during early stages of development of some biotech molecules in order to provide sufficient stability. Shipment of frozen product could potentially be performed in the frozen state, yet possibly at different temperatures, for example, using dry ice (-80 °C). Container closure systems of drug products usually consist of a glass vial, rubber stopper, and an aluminum crimped cap. In the frozen state, the glass transition temperature (Tg) of commonly used rubber stoppers is between -55 and -65 °C. Below their Tg, rubber stoppers are known to lose their elastic properties and become brittle, and thus potentially fail to maintain container closure integrity in the frozen state. Leaks during frozen temperature storage and transportation are likely to be transient, yet, can possibly risk container closure integrity and lead to microbial contamination. After thawing, the rubber stopper is supposed to re-seal the container closure system. Given the transient nature of the possible impact on container closure integrity in the frozen state, typical container closure integrity testing methods (used at room temperature conditions) are unable to evaluate and thus confirm container closure integrity in the frozen state. Here we present the development of a novel method (thermal physical container closure integrity) for direct assessment of container closure integrity by a physical method (physical container closure integrity) at frozen conditions, using a modified He leakage test. In this study, different container closure systems were evaluated with regard to physical container closure integrity in the frozen state to assess the suitability of vial/stopper combinations and were compared to a gas headspace method. In summary, the thermal physical container closure integrity He leakage method was more sensitive in detecting physical container closure integrity impact than gas headspace and aided identification of an unsuitable container closure system. Sometimes, drug product for parenteral administration is stored in a frozen state (e.g., -20 °C or -80 °C), particularly during early stages of development of some biotech molecules in order to provide sufficient stability. Container closure systems for drug products usually consist of a glass vial, rubber stopper, and an aluminum crimped cap. In the frozen state, the glass transition temperature (Tg) of commonly used rubber stoppers is between -55 and -65 °C. Leaks during frozen temperature storage and transportation are likely to be transient, yet they can possibly risk container closure integrity and lead to microbial contamination and sterility breach. After thawing, the rubber stopper is expected to re-seal the container closure system. Given the transient nature of the possible impact on container closure integrity in the frozen state, typical container closure integrity testing methods (used at room temperature conditions) are unable to evaluate and thus confirm container closure integrity in the frozen state. Here we present the development of a novel method (thermal container closure integrity) for direct measurement of container closure integrity by a physical method (physical container closure integrity) at frozen conditions, using a modified He leakage test. In this study, we found that the thermal container closure integrity He leakage method was more sensitive in detecting physical container closure integrity impact than gas headspace and aided identification of an unsuitable container closure system. © PDA, Inc. 2016.

  2. USER'S GUIDE TO CLOSURE EVALUATION SYSTEM: CES BETA-TEST VERSION 1.0

    EPA Science Inventory

    The Closure Evaluation System (CES) is a decision support tool, developed by the U.S. EPA's Risk Reduction Engineering Laboratory, to assist reviewers and preparers of Resource Conservation and Recovery Act (RCRA) Part B permit applications. CES is designed to serve as a checklis...

  3. Novel application of polyelectrolyte multilayers as nanoscopic closures with hermetic sealing.

    PubMed

    Marcott, Stephanie A; Ada, Sena; Gibson, Phillip; Camesano, Terri A; Nagarajan, R

    2012-03-01

    Closure systems for personnel protection applications, such as protective clothing or respirator face seals, should provide effective permeation barrier to toxic gases. Currently available mechanical closure systems based on the hook and loop types (example, Velcro) do not provide adequate barrier to gas permeation. To achieve hermetic sealing, we propose a nonmechanical, nanoscopic molecular closure system based on complementary polyelectrolyte multilayers, one with a polycation outermost layer and the other with a polyanion outermost layer. The closure surfaces were prepared by depositing polyelectrolyte multilayers under a variety of deposition conditions, on conformable polymer substrates (thin films of polyethylene teraphthalate, PET or polyimide, PI). The hermetic sealing property of the closures was evaluated by measuring the air flow resistance using the dynamic moisture permeation cell (DMPC) at different humidity conditions. The DMPC measurements show that the polyelectrolyte multilayer closures provide significantly large resistance to air flow, approximately 20-800 times larger than that possible with conventional hook and loop type closure systems, at all humidity levels (from 5 to 95% relative humidity). Hence, from the point of view of providing a hermetic seal against toxic gas permeation, the polyelectrolyte multilayer closures are viable candidates for further engineering development. However, the adhesive strength of the multilayer closures measured by atomic force microscopy suggests that the magnitude of adhesion is much smaller than what is possible with mechanical closures. Therefore, we envisage the development of a composite closure system combining the mechanical closure to provide strong adhesion and the multilayer closure to provide hermetic sealing. © 2012 American Chemical Society

  4. A computer analysis of reflex eyelid motion in normal subjects and in facial neuropathy.

    PubMed

    Somia, N N; Rash, G S; Epstein, E E; Wachowiak, M; Sundine, M J; Stremel, R W; Barker, J H; Gossman, D

    2000-12-01

    To demonstrate how computerized eyelid motion analysis can quantify the human reflex blink. Seventeen normal subjects and 10 patients with unilateral facial nerve paralysis were analyzed. Eyelid closure is currently evaluated by systems primarily designed to assess lower/midfacial movements. The methods are subjective, difficult to reproduce, and measure only volitional closure. Reflex closure is responsible for eye hydration, and its evaluation demands dynamic analysis. A 60Hz video camera incorporated into a helmet was used to analyze blinking. Reflective markers on the forehead and eyelids allowed for the dynamic measurement of the reflex blink. Eyelid displacement, velocity and acceleration were calculated. The degree of synchrony between bilateral blinks was also determined. This study demonstrates that video motion analysis can describe normal and altered eyelid motions in a quantifiable manner. To our knowledge, this is the first study to measure dynamic reflex blinks. Eyelid closure may now be evaluated in kinematic terms. This technique could increase understanding of eyelid motion and permit more accurate evaluation of eyelid function. Dynamic eyelid evaluation has immediate applications in the treatment of facial palsy affecting the reflex blink. Relevance No method has been developed that objectively quantifies dynamic eyelid closure. Methods currently in use evaluate only volitional eyelid closure, and are based on direct and indirect observer assessments. These methods are subjective and are incapable of analyzing dynamic eyelid movements, which are critical to maintenance of corneal hydration and comfort. A system that quantifies eyelid kinematics can provide a functional analysis of blink disorders and an objective evaluation of their treatment(s).

  5. Systematization of a set of closure techniques.

    PubMed

    Hausken, Kjell; Moxnes, John F

    2011-11-01

    Approximations in population dynamics are gaining popularity since stochastic models in large populations are time consuming even on a computer. Stochastic modeling causes an infinite set of ordinary differential equations for the moments. Closure models are useful since they recast this infinite set into a finite set of ordinary differential equations. This paper systematizes a set of closure approximations. We develop a system, which we call a power p closure of n moments, where 0≤p≤n. Keeling's (2000a,b) approximation with third order moments is shown to be an instantiation of this system which we call a power 3 closure of 3 moments. We present an epidemiological example and evaluate the system for third and fourth moments compared with Monte Carlo simulations. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Comparison Of Intake Gate Closure Methods At Lower Granite, Little Goose, Lower Monumental, And Mcnary Dams Using Risk-Based Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gore, Bryan F.; Blackburn, Tyrone R.; Heasler, Patrick G.

    2001-01-19

    The objective of this report is to compare the benefits and costs of modifications proposed for intake gate closure systems at four hydroelectric stations on the Lower Snake and Upper Columbia Rivers in the Walla Walla District that are unable to meet the COE 10-minute closure rule due to the installation of fish screens. The primary benefit of the proposed modifications is to reduce the risk of damage to the station and environs when emergency intake gate closure is required. Consequently, this report presents the results and methodology of an extensive risk analysis performed to assess the reliability of powerhousemore » systems and the costs and timing of potential damages resulting from events requiring emergency intake gate closure. As part of this analysis, the level of protection provided by the nitrogen emergency closure system was also evaluated. The nitrogen system was the basis for the original recommendation to partially disable the intake gate systems. The risk analysis quantifies this protection level.« less

  7. Hypernetted-chain-like closure of Ornstein-Zernike equation in multibody dissipative particle dynamics

    NASA Astrophysics Data System (ADS)

    Mo, Chao-jie; Qin, Li-zi; Yang, Li-jun

    2017-10-01

    We have derived a hypernetted-chain-like (HNC-like) approximate closure of the Ornstein-Zernike equation for multibody dissipative particle dynamics (MDPD) system in which the classic closures are not directly practicable. We first point out that the Percus's method is applicable to MDPD system in which particles interact with a density-dependent potential. And then an HNC-like closure is derived using Percus's idea and the saddle-point approximation of particle free energy. This HNC-like closure is compared with results of previous researchers, and in many cases, it demonstrates better agreement with computer simulation results. The HNC-like closure is used to predict the cluster crystallization in MDPD. We determine whether the cluster crystallization will happen in a system utilizing the widely applicable Hansen-Verlet freezing criterion and by observing the radial distribution function. The conclusions drawn from the results of the HNC-like closure are in agreement with computer simulation results. We evaluate different weight functions to determine whether they are prone to cluster crystallization. A new effective density-dependent pairwise potential is also proposed to help to explain the tendency to cluster crystallization of MDPD systems.

  8. A new cable-tie based sternal closure system: description of the device, technique of implantation and first clinical evaluation

    PubMed Central

    2012-01-01

    Background Wire closure still remains the preferred technique despite reasonable disadvantages. Associated complications, such as infection and sternal instability, cause time- and cost-consuming therapies. We present a new tool for sternal closure with its first clinical experience and results. Methods The sternal ZipFixTM System is based on the cable-tie principle. It primarily consists of biocompatible Poly-Ether-Ether-Ketone implants and is predominantly used peristernally through the intercostal space. The system provides a large implant-to-bone contact for better force distribution and for avoiding bone cut through. Results 50 patients were closed with the ZipFixTM system. No sternal instability was observed at 30 days. Two patients developed a mediastinitis that necessitated the removal of the device; however, the ZipFixTM were intact and the sternum remained stable. Conclusions In our initial evaluation, the short-term results have shown that the sternal ZipFixTM can be used safely and effectively. It is fast, easy to use and serves as a potential alternative for traditional wire closure. PMID:22731778

  9. Development of uniform standards for allowable lane closure : final report, September 2008.

    DOT National Transportation Integrated Search

    2008-09-01

    Procedures for determining allowable lane closure hours to perform maintenance, construction, resurfacing, regional permit and major access permit work on the state highway system were evaluated. The current process involves the collection of traffic...

  10. Evaluation of a new tension relief system for securing wound closure: A single-centre, Chinese cohort study

    PubMed Central

    Huahui, Zhang; Dan, Xue; Hongfei, Jiang; Hang, Hu; Chunmao, Han; Haitao, Ren; Jianxin, Yu; Zhiping, Tao

    2016-01-01

    BACKGROUND Wounds that have been closed under excessive tension, and skin defects that cannot be closed primarily, pose a daily challenge for the reconstructive surgeon. OBJECTIVE To evaluate a new tension relief system (TRS) device for skin stretching and secure wound closure. METHODS From September 2013 to March 2014, a consecutive series of 41 Chinese patients with 43 wounds were enrolled for application of 50 cycles of TRS therapy. TRS was used for two main clinical applications: closure of a variety of surgical/traumatic wounds; and securing wound closure after high-tension suture closure. Basic information and details regarding this therapy and its complications were recorded. Follow-up visits were conducted three to six months after wound closure. RESULTS Mean residual wound width decreased approximately 20% every two days during cycles of TRS therapy. Infection was the most common complication (five cases). Other complications included dehiscence (two cases) and pressure ulcer (one case). At the six-month follow-up visit, (21 wounds in 20 patients), both the extent of healing and the scar were acceptable. DISCUSSION There are no absolute contraindications to TRS therapy. The authors have formulated instructions for the prevention and treatment of the most common complications. CONCLUSIONS The results demonstrate that TRS therapy is a simple, effective method for primary closure of difficult wounds, and large skin and soft-tissue defects. Larger randomized studies are required to further evaluate of the effectiveness, indications, complications and cost effectiveness of this innovative TRS therapy. PMID:28439506

  11. Implementation of an Outer Can Welding System for Savannah River Site FB-Line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard, S.R.

    2003-03-27

    This paper details three phases of testing to confirm use of a Gas Tungsten Arc (GTA) system for closure welding the 3013 outer container used for stabilization/storage of plutonium metals and oxides. The outer container/lid closure joint was originally designed for laser welding, but for this application, the gas tungsten arc (GTA) welding process has been adapted. The testing progressed in three phases: (1) system checkout to evaluate system components for operational readiness, (2) troubleshooting to evaluate high weld failure rates and develop corrective techniques, and (3) pre-installation acceptance testing.

  12. High-performance space shuttle auxiliary propellant valve system

    NASA Technical Reports Server (NTRS)

    Smith, G. M.

    1973-01-01

    Several potential valve closures for the space shuttle auxiliary propulsion system (SS/APS) were investigated analytically and experimentally in a modeling program. The most promising of these were analyzed and experimentally evaluated in a full-size functional valve test fixture of novel design. The engineering investigations conducted for both model and scale evaluations of the SS/APS valve closures and functional valve fixture are described. Preliminary designs, laboratory tests, and overall valve test fixture designs are presented, and a final recommended flightweight SS/APS valve design is presented.

  13. Artificial Leaks in Container Closure Integrity Testing: Nonlinear Finite Element Simulation of Aperture Size Originated by a Copper Wire Sandwiched between the Stopper and the Glass Vial.

    PubMed

    Nieto, Alejandra; Roehl, Holger; Brown, Helen; Adler, Michael; Chalus, Pascal; Mahler, Hanns-Christian

    2016-01-01

    Container closure integrity (CCI) testing is required by different regulatory authorities in order to provide assurance of tightness of the container closure system against possible contamination, for example, by microorganisms. Microbial ingress CCI testing is performed by incubation of the container closure system with microorganisms under specified testing conditions. Physical CCI uses surrogate endpoints, such as coloration by dye solution ingress or gas flow (helium leakage testing). In order to correlate microbial CCI and physical CCI test methods and to evaluate the methods' capability to detect a given leak, artificial leaks are being introduced into the container closure system in a variety of different ways. In our study, artificial leaks were generated using inserted copper wires between the glass vial opening and rubber stopper. However, the insertion of copper wires introduces leaks of unknown size and shape. With nonlinear finite element simulations, the aperture size between the rubber stopper and the glass vial was calculated, depending on wire diameter and capping force. The dependency of the aperture size on the copper wire diameter was quadratic. With the data obtained, we were able to calculate the leak size and model leak shape. Our results suggest that the size as well as the shape of the artificial leaks should be taken into account when evaluating critical leak sizes, as flow rate does not, independently, correlate to hole size. Capping force also affected leak size. An increase in the capping force from 30 to 70 N resulted in a reduction of the aperture (leak size) by approximately 50% for all wire diameters. From 30 to 50 N, the reduction was approximately 33%. Container closure integrity (CCI) testing is required by different regulatory authorities in order to provide assurance of tightness of the container closure system against contamination, for example, by microorganisms. Microbial ingress CCI testing is performed by incubation of the container closure system with microorganisms under specified testing conditions. Physical CCI uses surrogate endpoints, such as coloration by dye solution ingress or gas flow. In order to correlate microbial ingress CCI and physical CCI test methods and to evaluate the methods' capability to detect a given leak, artificially created defects (artificial leaks) are being introduced into the container closure system in a variety of different ways. In our study, artificial leaks were generated using inserted copper wires between the glass vial opening and rubber stopper. Up to date, the insertion of copper wires introduced leaks of unknown size and shape. With nonlinear finite element simulations, the effective aperture size between the rubber stopper and the glass vial was calculated, depending on wire diameter and capping force, and the leak shape was modelled. Our results suggest that the size as well as the shape of the artificial leaks should be taken into account when evaluating critical leak sizes, as flow rate does not, independently, correlate to the hole size. © PDA, Inc. 2016.

  14. A Practical Scoring System to Select Optimally Sized Devices for Percutaneous Patent Foramen Ovale Closure.

    PubMed

    Venturini, Joseph M; Retzer, Elizabeth M; Estrada, J Raider; Mediratta, Anuj; Friant, Janet; Nathan, Sandeep; Paul, Jonathan D; Blair, John; Lang, Roberto M; Shah, Atman P

    2016-10-01

    Patent foramen ovale (PFO) has been linked to cryptogenic stroke, and closure has been reported to improve clinical outcomes. However, there are no clear guidelines to direct device sizing. This study sought to use patient characteristics and echocardiographic findings to create a prediction score for device sizing. This was a retrospective review of patients undergoing percutaneous PFO closure at our institution between July 2010 and December 2014. Demographic and clinical characteristics were recorded, and all pre- and intraprocedural echocardiography results were evaluated. Thirty-six patients underwent percutaneous PFO closure during the study period. All procedures were performed using an Amplatzer Septal Occluder "Cribriform" (ASOC) device in one of three disc diameters: 25, 30, or 35 mm. Closure was indicated for cryptogenic stroke/transient ischemic attack in 75% of cases. Every case (100%) was successful with durable shunt correction at the 6-month follow-up without complications of erosion or device embolization. The presence of atrial septal aneurysm (ASA) ( p = 0.027) and PFO tunnel length >10 mm ( p = 0.038) were independently associated with increased device size. A scoring system of 1 point for male sex, 1 point for ASA, and 1 point for PFO tunnel >10 mm long was associated with the size of closure device implanted ( p = 0.006). A simple scoring system may be used to select an optimally sized device for percutaneous PFO closure using the ASOC device.

  15. Novel percutaneous suture-mediated patent foramen ovale closure technique. Early results of the NobleStitch EL Italian Registry.

    PubMed

    Gaspardone, Achille; De Marco, Federico; Sgueglia, Gregory A; De Santis, Antonella; Iamele, Maria; D'Ascoli, Emanuela; Tusa, Maurizio; Corciu, Anca; Mullen, Michael; Nobles, Anthony; Carminati, Mario; Bedogni, Francesco

    2018-04-03

    To assess the efficacy of a novel percutaneous "device-less" suture mediated patent foramen ovale (PFO) closure system. Between June 2016 and October 2017, a prospective registry aimed at assessing the safety and efficacy of the NobleStitch EL (HeartStitch, Fountain Valley, CA) suture-based PFO closure system was carried out at 12 sites in Italy. Among 200 consecutive evaluated patients, 192 were considered suitable for suture-mediated PFO closure (44±13 years, 114 women). Suture of the septum with the NobleStitch EL system was carried out successfully in 186 (96%) patients. Median fluoroscopy time was 16.1 (13.0-22.5) minutes and contrast volume 200 (150-270) ml. At 206±130 days follow-up, microbubbles transthoracic echocardiography with Valsalva maneuver revealed no RLS (grade 0) in 139 (75%) patients and RLS grade ≤1 in 166 (89%) patients. Significant RLS was present in 20 (11%) patients (grade 2 and 3 in 11 and 9 patients, respectively). There were no device-related complications. The early results of this first Italian Registry indicates that the suture mediated "deviceless" closure of PFO is feasible in the majority of septal anatomies, provides an effective closure of PFO comparable to traditional devices with an excellent safety profile at medium term follow-up.

  16. ICPP tank farm closure study. Volume 2: Engineering design files

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-02-01

    Volume 2 contains the following topical sections: Tank farm heel flushing/pH adjustment; Grouting experiments for immobilization of tank farm heel; Savannah River high level waste tank 20 closure; Tank farm closure information; Clean closure of tank farm; Remediation issues; Remote demolition techniques; Decision concerning EIS for debris treatment facility; CERCLA/RCRA issues; Area of contamination determination; Containment building of debris treatment facility; Double containment issues; Characterization costs; Packaging and disposal options for the waste resulting from the total removal of the tank farm; Take-off calculations for the total removal of soils and structures at the tank farm; Vessel off-gas systems; Jet-groutedmore » polymer and subsurface walls; Exposure calculations for total removal of tank farm; Recommended instrumentation during retrieval operations; High level waste tank concrete encasement evaluation; Recommended heavy equipment and sizing equipment for total removal activities; Tank buoyancy constraints; Grout and concrete formulas for tank heel solidification; Tank heel pH requirements; Tank cooling water; Evaluation of conservatism of vehicle loading on vaults; Typical vault dimensions and approximately tank and vault void volumes; Radiological concerns for temporary vessel off-gas system; Flushing calculations for tank heels; Grout lift depth analysis; Decontamination solution for waste transfer piping; Grout lift determination for filling tank and vault voids; sprung structure vendor data; Grout flow properties through a 2--4 inch pipe; Tank farm load limitations; NRC low level waste grout; Project data sheet calculations; Dose rates for tank farm closure tasks; Exposure and shielding calculations for grout lines; TFF radionuclide release rates; Documentation of the clean closure of a system with listed waste discharge; and Documentation of the ORNL method of radionuclide concentrations in tanks.« less

  17. Effectiveness of percutaneous closure of patent foramen ovale for hypoxemia.

    PubMed

    Fenster, Brett E; Nguyen, Bryant H; Buckner, J Kern; Freeman, Andrew M; Carroll, John D

    2013-10-15

    The aim of this study was to evaluate the ability of percutaneous patent foramen ovale (PFO) closure to improve systemic hypoxemia. Although PFO-mediated right-to-left shunt (RTLS) is associated with hypoxemia, the ability of percutaneous closure to ameliorate hypoxemia is unknown. Between 2004 and 2009, 97 patients who underwent PFO closure for systemic hypoxemia and dyspnea that was disproportionate to underlying lung disease were included for evaluation. All patients exhibited PFO-mediated RTLS as determined by agitated saline echocardiography. Procedural success was defined as implantation of a device without major complications and mild or no residual shunt at 6 months. Clinical success was defined as a composite of an improvement in New York Heart Association (NYHA) functional class, reduction of dyspnea symptoms, or decreased oxygen requirement. Procedural success was achieved in 96 of 97 (99%), and clinical success was achieved in 68 of 97 (70%). The presence of any moderate or severe interatrial shunt by agitated saline study (odds ratio [OR] = 4.7; p <0.024), NYHA class at referral (OR = 2.9; p <0.0087), and 10-year increase in age (OR = 1.8; p <0.0017) increased likelihood of clinical success. In contrast, a pulmonary comorbidity (OR = 0.18; p <0.005) and male gender (OR = 0.30; p <0.017) decreased the likelihood of success. In conclusion, based on the largest single-center experience of patients referred for PFO closure for systemic hypoxemia, PFO closure was a mechanically effective procedure with an associated improvement in echocardiographic evidence of RTLS, NYHA functional class, and oxygen requirement. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Parametric Analysis of Life Support Systems for Future Space Exploration Missions

    NASA Technical Reports Server (NTRS)

    Swickrath, Michael J.; Anderson, Molly S.; Bagdigian, Bob M.

    2011-01-01

    The National Aeronautics and Space Administration is in a process of evaluating future targets for space exploration. In order to maintain the welfare of a crew during future missions, a suite of life support technology is responsible for oxygen and water generation, carbon dioxide control, the removal of trace concentrations of organic contaminants, processing and recovery of water, and the storage and reclamation of solid waste. For each particular life support subsystem, a variety competing technologies either exist or are under aggressive development efforts. Each individual technology has strengths and weaknesses with regard to launch mass, power and cooling requirements, volume of hardware and consumables, and crew time requirements for operation. However, from a system level perspective, the favorability of each life support architecture is better assessed when the sub-system technologies are analyzed in aggregate. In order to evaluate each specific life support system architecture, the measure of equivalent system mass (ESM) was employed to benchmark system favorability. Moreover, the results discussed herein will be from the context of loop-closure with respect to the air, water, and waste sub-systems. Specifically, closure relates to the amount of consumables mass that crosses the boundary of the vehicle over the lifetime of a mission. As will be demonstrated in this manuscript, the optimal level of loop closure is heavily dependent upon mission requirements such as duration and the level of extra-vehicular activity (EVA) performed. Sub-system level trades were also considered as a function of mission duration to assess when increased loop closure is practical. Although many additional factors will likely merit consideration in designing life support systems for future missions, the ESM results described herein provide a context for future architecture design decisions toward a flexible path program.

  19. Machine Learning-based discovery of closures for reduced models of dynamical systems

    NASA Astrophysics Data System (ADS)

    Pan, Shaowu; Duraisamy, Karthik

    2017-11-01

    Despite the successful application of machine learning (ML) in fields such as image processing and speech recognition, only a few attempts has been made toward employing ML to represent the dynamics of complex physical systems. Previous attempts mostly focus on parameter calibration or data-driven augmentation of existing models. In this work we present a ML framework to discover closure terms in reduced models of dynamical systems and provide insights into potential problems associated with data-driven modeling. Based on exact closure models for linear system, we propose a general linear closure framework from viewpoint of optimization. The framework is based on trapezoidal approximation of convolution term. Hyperparameters that need to be determined include temporal length of memory effect, number of sampling points, and dimensions of hidden states. To circumvent the explicit specification of memory effect, a general framework inspired from neural networks is also proposed. We conduct both a priori and posteriori evaluations of the resulting model on a number of non-linear dynamical systems. This work was supported in part by AFOSR under the project ``LES Modeling of Non-local effects using Statistical Coarse-graining'' with Dr. Jean-Luc Cambier as the technical monitor.

  20. Packaging Considerations for Biopreservation

    PubMed Central

    Woods, Erik J.; Thirumala, Sreedhar

    2011-01-01

    Summary The packaging system chosen for biopreservation is critical for many reasons. An ideal biopreservation container system must provide for closure integrity, sample stability and ready access to the preserved material. This means the system needs to be hermetically sealed to ensure integrity of the specimen is maintained throughout processing, storage and distribution; the system must remain stable over long periods of time as many biobanked samples may be stored indefinitely; and functionally closed access systems must be used to avoid contamination upon sample withdraw. This study reviews the suitability of a new commercially available vial configuration container utilizing blood bag style closure and access systems that can be hermetically sealed and remain stable through cryopreservation and biobanking procedures. This vial based systems allow for current good manufacturing/tissue practice (cGTP) requirements during processing of samples and may provide the benefit of ease of delivery by a care giver. In this study, the CellSeal® closed system cryovial was evaluated and compared to standard screw cap vials. The CellSeal system was evaluated for durability, closure integrity through transportation and maintenance of functional viability of a cryopreserved mesenchymal stem cell model. The results of this initial proof-of-concept study indicated that the CellSeal vials are highly suitable for biopreservation and biobanking, and provide a suitable container system for clinical and commercial cell therapy products frozen in small volumes. PMID:21566715

  1. Application of empirical and dynamical closure methods to simple climate models

    NASA Astrophysics Data System (ADS)

    Padilla, Lauren Elizabeth

    This dissertation applies empirically- and physically-based methods for closure of uncertain parameters and processes to three model systems that lie on the simple end of climate model complexity. Each model isolates one of three sources of closure uncertainty: uncertain observational data, large dimension, and wide ranging length scales. They serve as efficient test systems toward extension of the methods to more realistic climate models. The empirical approach uses the Unscented Kalman Filter (UKF) to estimate the transient climate sensitivity (TCS) parameter in a globally-averaged energy balance model. Uncertainty in climate forcing and historical temperature make TCS difficult to determine. A range of probabilistic estimates of TCS computed for various assumptions about past forcing and natural variability corroborate ranges reported in the IPCC AR4 found by different means. Also computed are estimates of how quickly uncertainty in TCS may be expected to diminish in the future as additional observations become available. For higher system dimensions the UKF approach may become prohibitively expensive. A modified UKF algorithm is developed in which the error covariance is represented by a reduced-rank approximation, substantially reducing the number of model evaluations required to provide probability densities for unknown parameters. The method estimates the state and parameters of an abstract atmospheric model, known as Lorenz 96, with accuracy close to that of a full-order UKF for 30-60% rank reduction. The physical approach to closure uses the Multiscale Modeling Framework (MMF) to demonstrate closure of small-scale, nonlinear processes that would not be resolved directly in climate models. A one-dimensional, abstract test model with a broad spatial spectrum is developed. The test model couples the Kuramoto-Sivashinsky equation to a transport equation that includes cloud formation and precipitation-like processes. In the test model, three main sources of MMF error are evaluated independently. Loss of nonlinear multi-scale interactions and periodic boundary conditions in closure models were dominant sources of error. Using a reduced order modeling approach to maximize energy content allowed reduction of the closure model dimension up to 75% without loss in accuracy. MMF and a comparable alternative model peformed equally well compared to direct numerical simulation.

  2. Congenital portosystemic shunts: diagnosis and treatment.

    PubMed

    Franchi-Abella, Stéphanie; Gonzales, Emmanuel; Ackermann, Oanez; Branchereau, Sophie; Pariente, Danièle; Guérin, Florent

    2018-05-05

    Congenital portosystemic shunts (CPSS) are rare vascular malformations that create an abnormal connection between portal and systemic veins resulting in complete or partial diversion of the portal flow away from the liver to the systemic venous system. Different anatomic types exist and several classifications have been proposed. They can be associated with other malformations especially cardiac and heterotaxia. The main complications include hepatic encephalopathy, liver tumors, portopulmonary hypertension, and pulmonary arteriovenous shunts. Diagnosis relies on imaging, and prenatal diagnosis is possible. Spontaneous closure of the CPSS is possible in some anatomic forms during the first year of life. When the CPSS remains patent, radiologic or surgical closure of the CPSS may prevent, resolve, or stabilize complications. Interventional radiology plays a key role for both the preoperative evaluation with occlusion test to assess the exact anatomy and to measure portal pressure after occlusion of the CPSS. Endovascular closure is the first option for treatment when possible.

  3. Twenty-four month results from a randomized trial of cyanoacrylate closure versus radiofrequency ablation for the treatment of incompetent great saphenous veins.

    PubMed

    Gibson, Kathleen; Morrison, Nick; Kolluri, Raghu; Vasquez, Michael; Weiss, Robert; Cher, Daniel; Madsen, Monte; Jones, Andrew

    2018-06-15

    We previously reported 3-month and 12-month occlusion rates after treatment of clinically symptomatic saphenous vein reflux with either cyanoacrylate closure (CAC) using the VenaSeal Closure System (Medtronic, Dublin, Ireland) or radiofrequency ablation (RFA) in a randomized, multicenter, clinical trial, VenaSeal Sapheon Closure System vs Radiofrequency Ablation for Incompetent Great Saphenous Veins (VeClose). Herein we report the 24-month follow-up results of the VeClose trial. There were 222 patients with symptomatic great saphenous vein (GSV) incompetence who were randomly assigned to receive either CAC (n = 108) or RFA (n = 114). Patients were not allowed to receive adjunctive treatment of tributary varicosities until after the 3-month visit. Duplex ultrasound of the target vein was performed at day 3 and months 1, 3, 6, 12, and 24 after treatment, and closure was assessed by ultrasound by the treating physician. Overall 24-month success rates were compared; in addition, time to first reopening of the target vein was evaluated using survival analysis. End points such as Venous Clinical Severity Score, EuroQoL-5 Dimension, and Aberdeen Varicose Vein Questionnaire were evaluated. Of 222 randomized patients, 171 completed the 24-month follow-up, which included 87 from the CAC group and 84 from the RFA group. The 24-month complete closure rate was 95.3% in the CAC group and 94.0% in the RFA group, demonstrating continued noninferiority of CAC compared with RFA (P = .0034). Symptoms and quality of life improved similarly in both groups. No clinically significant device- or procedure-related late adverse events occurred. Both CAC and RFA were effective in closure of the target GSV, resulting in similar and significant improvements in the patient's quality of life through 24 months. These results suggest that CAC of the GSV is safe and durable out to 2 years. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Evaluation of Container Closure System Integrity for Storage of Frozen Drug Products: Impact of Capping Force and Transportation.

    PubMed

    Nieto, Alejandra; Roehl, Holger; Adler, Michael; Mohl, Silke

    2018-05-31

    Frozen-state storage and cold-chain transport are key operations in the development and commercialization of biopharmaceuticals. Nowadays, a few marketed drug products are stored (and/or) shipped under frozen conditions to ensure sufficient stability, particularly for live viral vaccines. When these products are stored in glass vials with stoppers, the elastomer of the stopper needs to be flexible enough to seal the vial at the target's lowest temperature to ensure container closure integrity and hence both sterility and safety of the drug product. The container closure integrity assessment in the frozen state (e.g., -20°C, -80°C) should include: Container Closure Integrity (CCI) of the Container Closure System (CCS) itself, impact of processing, e.g. capping process on CCI and impact of shipment and movement on CCI in the frozen state. The objective of this work was an evaluation of the impact of processing and shipment on CCI of a CCS in the frozen state. The impact on other quality attributes was not investigated. In this light, the ThermCCI method was applied to evaluate the impact of shipping stress and variable capping force on CCI of frozen vials and to evaluate the temperature limits of rubber stoppers. In conclusion, retaining CCI during cold storage is mostly a function of vial-stopper combination and temperatures below -40°C may pose a risk to the CCI of a frozen drug product. Variable capping force may have an influence on the CCI of a frozen drug product if not appropriately assessed. Regarding the impact of shipment on the CCI of glass vials, no indication was given either at room temperature, -20°C or -75°C when compared to static storage at such temperatures. Copyright © 2018, Parenteral Drug Association.

  5. Efficient algorithms and implementations of entropy-based moment closures for rarefied gases

    NASA Astrophysics Data System (ADS)

    Schaerer, Roman Pascal; Bansal, Pratyuksh; Torrilhon, Manuel

    2017-07-01

    We present efficient algorithms and implementations of the 35-moment system equipped with the maximum-entropy closure in the context of rarefied gases. While closures based on the principle of entropy maximization have been shown to yield very promising results for moderately rarefied gas flows, the computational cost of these closures is in general much higher than for closure theories with explicit closed-form expressions of the closing fluxes, such as Grad's classical closure. Following a similar approach as Garrett et al. (2015) [13], we investigate efficient implementations of the computationally expensive numerical quadrature method used for the moment evaluations of the maximum-entropy distribution by exploiting its inherent fine-grained parallelism with the parallelism offered by multi-core processors and graphics cards. We show that using a single graphics card as an accelerator allows speed-ups of two orders of magnitude when compared to a serial CPU implementation. To accelerate the time-to-solution for steady-state problems, we propose a new semi-implicit time discretization scheme. The resulting nonlinear system of equations is solved with a Newton type method in the Lagrange multipliers of the dual optimization problem in order to reduce the computational cost. Additionally, fully explicit time-stepping schemes of first and second order accuracy are presented. We investigate the accuracy and efficiency of the numerical schemes for several numerical test cases, including a steady-state shock-structure problem.

  6. Cold Plasma Welding System for Surgical Skin Closure: In Vivo Porcine Feasibility Assessment.

    PubMed

    Harats, Moti; Lam, Amnon; Maller, Michael; Kornhaber, Rachel; Haik, Josef

    2016-09-29

    Cold plasma skin welding is a novel technology that bonds skin edges through soldering without the use of synthetic materials or conventional wound approximation methods such as sutures, staples, or skin adhesives. The cold plasma welding system uses a biological solder applied to the edges of a skin incision, followed by the application of cold plasma energy. The objectives of this study were to assess the feasibility of a cold plasma welding system in approximating and fixating skin incisions compared with conventional methods and to evaluate and define optimal plasma welding parameters and histopathological tissue response in a porcine model. The cold plasma welding system (BioWeld1 System, IonMed Ltd, Yokneam, Israel) was used on porcine skin incisions using variable energy parameters. Wound healing was compared macroscopically and histologically to incisions approximated with sutures. When compared to sutured skin closure, cold plasma welding in specific system parameters demonstrated comparable and favorable wound healing results histopathologically as well as macroscopically. No evidence of epidermal damage, thermal or otherwise, was encountered in the specified parameters. Notably, bleeding, infection, and wound dehiscence were not detected at incision sites. Skin incisions welded at extreme energy parameters presented second-degree burns. Implementation of cold plasma welding has been shown to be feasible for skin closure. Initial in vivo results suggest cold plasma welding might provide equal, if not better, healing results than traditional methods of closure.

  7. Impact of Vial Capping on Residual Seal Force and Container Closure Integrity.

    PubMed

    Mathaes, Roman; Mahler, Hanns-Christian; Roggo, Yves; Ovadia, Robert; Lam, Philippe; Stauch, Oliver; Vogt, Martin; Roehl, Holger; Huwyler, Joerg; Mohl, Silke; Streubel, Alexander

    2016-01-01

    The vial capping process is a critical unit operation during drug product manufacturing, as it could possibly generate cosmetic defects or even affect container closure integrity. Yet there is significant variability in capping equipment and processes, and their relation to potential defects or container closure integrity has not been thoroughly studied. In this study we applied several methods-residual seal force tester, a self-developed system of a piezo force sensor measurement, and computed tomography-to characterize different container closure system combinations that had been sealed using different capping process parameter settings. Additionally, container closure integrity of these samples was measured using helium leakage (physical container closure integrity) and compared to characterization data. The different capping equipment settings lead to residual seal force values from 7 to 115 N. High residual seal force values were achieved with high capping pre-compression force and a short distance between the capping plate and plunge. The choice of container closure system influenced the obtained residual seal force values. The residual seal force tester and piezoelectric measurements showed similar trends. All vials passed physical container closure integrity testing, and no stopper rupture was seen with any of the settings applied, suggesting that container closure integrity was warranted for the studied container closure system with the chosen capping setting ranges. The vial capping process is a critical unit operation during drug product manufacturing, as it could possibly generate cosmetic defects or even affect container closure integrity. Yet there is significant variability in capping equipment and processes, and their relation to potential defects or container closure integrity has not been thoroughly studied. In this study we applied several methods-residual seal force tester, a self-developed system of a piezo force sensor measurement, and computed tomography-to characterize different container closure system combinations that had been sealed using different capping process parameter settings. The residual seal force tester can analyze a variety of different container closure systems independent of the capping equipment. An adequate and safe residual seal force range for each container closure system configuration can be established with the residual seal force tester and additional methods like computed tomography scans and leak testing. In the residual seal force range studied, the physical container closure integrity of the container closure system was warranted. © PDA, Inc. 2016.

  8. System for closure of a physical anomaly

    DOEpatents

    Bearinger, Jane P; Maitland, Duncan J; Schumann, Daniel L; Wilson, Thomas S

    2014-11-11

    Systems for closure of a physical anomaly. Closure is accomplished by a closure body with an exterior surface. The exterior surface contacts the opening of the anomaly and closes the anomaly. The closure body has a primary shape for closing the anomaly and a secondary shape for being positioned in the physical anomaly. The closure body preferably comprises a shape memory polymer.

  9. Site closure management strategies and the responsiveness of conservation outcomes in recreational fishing.

    PubMed

    Gao, Lei; Hailu, Atakelty

    2018-02-01

    We develop and use an empirically based model, which integrates fishing behaviour and a coral reef system, to evaluate outcomes from site closure strategies to manage the effects of recreational fishing. The model is designed to estimate management effects in complex settings with two-way feedback effects (between fishing and ecosystem dynamics) as well as spillover effects where the closure of a site (or sites) leads to the redistribution of fishing effort. An iconic coral reef system is used as a case study. The results demonstrate that some site closure strategies provide little incremental benefits over less stringent approaches. They also show that some strategies targeting more sites are actually inferior to more limited strategies, demonstrating that, in the analysis of complex problems involving feedback effects and substitutions, there is little substitute for the use of empirically based and sound modelling as the basis for informed conservation decision making and stakeholder consultation. These findings have direct relevance not only for policies aimed at improving recreational fishing management but also for securing the supply of marine ecosystem services. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Percutaneous device closure of patent ductus arteriosus with pulmonary artery hypertension: long-term results.

    PubMed

    Vijayalakshmi, Ishwarappa Balekundri; Setty, Natraj; Narasimhan, Chitra; Singla, Vivek; Manjunath, Cholenahalli Nanjappa

    2014-12-01

    Device closure of patent ductus arteriosus (PDA) is treatment of choice. But device closure in presence of pulmonary artery hypertension (PAH) remains a challenge. Data on patient selection, technical considerations, and complications are limited. To know the challenges and efficacy of device closure of PDA with PAH. Out of 1,325 cases of device closure of PDA, 246 (18.6%) with PAH formed the study material. To test the feasibility, chosen device is used to occlude PDA for ten minutes without oxygen inhalation. The device is released only if PAH reduced. PAH decreased in all except in 1 patient after closure with muscular ventricular septal occluder (MVSDO), pulmonary artery pressure (PAP) transiently increased (became supra-systemic), without significant reduction in aortic pressure. Device embolized in 8 patients (3.3%). Percutaneous retrieval was done in 4 (by snare in 2 and by fixing the cable to device in 2) and replaced with bigger devices. The surgical removal of the embolized MVSDO and ligation was done in 4 cases. All patients were on oral sildenafil and bosentan until PAP regressed to normal. Follow up was from 6 months to 9 years. No residual shunt in any patient on follow-up. The PAP regressed to normal in all except 5 cases (2.03%) of Down's syndrome with systemic PAP. Device closure of PDA with PAH is feasible, safe in all age groups. Temporary PDA occlusion with device is effective and time saving for evaluating pulmonary vascular reactivity. Device embolization in aorta is higher with severe PAH. Novel method of retrieval is effective. © 2014, Wiley Periodicals, Inc.

  11. [Evaluation of the external tissue extender (Ete) in secondary wound closure].

    PubMed

    Zutt, Markus; Beckmann, Iris; Kretschmer, Lutz

    2003-09-01

    For surgical closure of large skin defects, elaborate reconstructive plastic surgery or other methods such as internal subcutaneous balloon tissue expanders are required in order to avoid tension on the closure margins. Here we point to the benefits and disadvantages of an improved and simple method of secondary wound closure by secondary sutures. We employed a system called External Tissue Extender (ETE), which consists of silicone strings and plastic stoppers pulling the corresponding surgical sites together and evenly distributing the tension. Possible indications in dermatologic surgery and our experiences with this technique are outlined. Implantation and handling of the ETE are very easy and fast. The functional results are good and the cosmetic outcome satisfactory. More invasive surgical procedures can be avoided by using this method. A major disadvantage is the possibility of developing necrosis under the plastic stoppers. According to our experience, the ETE is a useful alternative indicated in certain dermatosurgical situations.

  12. Corrective Action Decision Document for Corrective Action Unit 428: Area 3 Septic Waste Systems 1 and 5, Tonopah Test Range, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    U.S. Department of Energy, Nevada Operations Office

    2000-02-08

    This Corrective Action Decision Document identifies and rationalizes the US Department of Energy, Nevada Operations Office's selection of a recommended corrective action alternative (CAA) appropriate to facilitate the closure of Corrective Action Unit (CAU) 428, Septic Waste Systems 1 and 5, under the Federal Facility Agreement and Consent Order. Located in Area 3 at the Tonopah Test Range (TTR) in Nevada, CAU 428 is comprised of two Corrective Action Sites (CASs): (1) CAS 03-05-002-SW01, Septic Waste System 1 and (2) CAS 03-05-002- SW05, Septic Waste System 5. A corrective action investigation performed in 1999 detected analyte concentrations that exceeded preliminarymore » action levels; specifically, contaminants of concern (COCs) included benzo(a) pyrene in a septic tank integrity sample associated with Septic Tank 33-1A of Septic Waste System 1, and arsenic in a soil sample associated with Septic Waste System 5. During this investigation, three Corrective Action Objectives (CAOs) were identified to prevent or mitigate exposure to contents of the septic tanks and distribution box, to subsurface soil containing COCs, and the spread of COCs beyond the CAU. Based on these CAOs, a review of existing data, future use, and current operations in Area 3 of the TTR, three CAAs were developed for consideration: Alternative 1 - No Further Action; Alternative 2 - Closure in Place with Administrative Controls; and Alternative 3 - Clean Closure by Excavation and Disposal. These alternatives were evaluated based on four general corrective action standards and five remedy selection decision factors. Based on the results of the evaluation, the preferred CAA was Alternative 3. This alternative meets all applicable state and federal regulations for closure of the site and will eliminate potential future exposure pathways to the contaminated soils at the Area 3 Septic Waste Systems 1 and 5.« less

  13. Efficient algorithms and implementations of entropy-based moment closures for rarefied gases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaerer, Roman Pascal, E-mail: schaerer@mathcces.rwth-aachen.de; Bansal, Pratyuksh; Torrilhon, Manuel

    We present efficient algorithms and implementations of the 35-moment system equipped with the maximum-entropy closure in the context of rarefied gases. While closures based on the principle of entropy maximization have been shown to yield very promising results for moderately rarefied gas flows, the computational cost of these closures is in general much higher than for closure theories with explicit closed-form expressions of the closing fluxes, such as Grad's classical closure. Following a similar approach as Garrett et al. (2015) , we investigate efficient implementations of the computationally expensive numerical quadrature method used for the moment evaluations of the maximum-entropymore » distribution by exploiting its inherent fine-grained parallelism with the parallelism offered by multi-core processors and graphics cards. We show that using a single graphics card as an accelerator allows speed-ups of two orders of magnitude when compared to a serial CPU implementation. To accelerate the time-to-solution for steady-state problems, we propose a new semi-implicit time discretization scheme. The resulting nonlinear system of equations is solved with a Newton type method in the Lagrange multipliers of the dual optimization problem in order to reduce the computational cost. Additionally, fully explicit time-stepping schemes of first and second order accuracy are presented. We investigate the accuracy and efficiency of the numerical schemes for several numerical test cases, including a steady-state shock-structure problem.« less

  14. An evaluation of abdominal wall closure in general surgical and gynecological residents.

    PubMed

    Williams, Z; Williams, S; Easley, H A; Seita, H M; Hope, W W

    2017-12-01

    To evaluate abdominal wall closure knowledge base and technical skills in surgical and OB/GYN residents. Residents consented to participate in a skills laboratory and quiz. The skills portion involved closure of a 10-cm incision on a simulated abdominal wall. Participants were timed, filmed, and graded using a standardized grading system. Thirty surgical and OB/GYN residents participated. All residents reported closing the abdominal wall continuously, 97% preferred slowly absorbing sutures (28/29), 97% preferred taking 1-cm bites (29/30), and 93% spaced bites 1 cm apart (27/29). However, 77% (10/13) of surgery residents identified 4:1 as the ideal suture to wound length ratio; 47% (7/15) of OB/GYN residents believed it to be 2:1, and another 40% (6/15) indicated 3:1 (p < 0.0001). In the simulation, OB/GYN residents used significantly fewer stitches (p = 0.0028), significantly more distance between bites (p < 0.0001), and significantly larger bite size (p < 0.0001) than surgery residents. When graded, there was no significant difference between programs. Despite some knowledge regarding the principles of abdominal wall closure among surgical and OB/GYN residents, more instruction is needed. We identified some differences in knowledge base and techniques for abdominal wall closure among general surgery and OB/GYN residents, which are likely due to differences in educational curriculums.

  15. Subcostal closure technique for prevention of postthoracotomy pain syndrome.

    PubMed

    Hong, Kipyo; Bae, Mikyung; Han, Sora

    2016-09-01

    The purpose of this study was to evaluate the efficacy of our subcostal closure technique in prevention of postthoracotomy pain syndrome. From July 2012 to March 2015, 29 patients in whom a lobectomy was indicated underwent a thoracotomy. The thoracotomy wounds were closed using a subcostal closure technique (subcostal closure group) and outcomes were compared with 31 patients who underwent video-assisted thoracoscopic surgery (thoracoscopy group). The duration of oral opioid consumption was evaluated from medical records, and postoperative pain was evaluated by telephone interview conducted by a trained nurse practitioner who was unaware of the patient's group. Pain scores were higher in the thoracoscopy group compared to the subcostal closure group, reaching statistical significance (Numeric Rating Scale 0.55 ± 0.948 in the subcostal closure group vs. 1.84 ± 1.614 in the thoracoscopy group; p < 0.001, Clinical Pain Scale 0.24 ± 0.435 in the subcostal closure group vs. 0.81 ± 0.703 in the thoracoscopy group; p < 0.001). The number of patients who consumed oral opioids for longer than 2 months after the operation was significantly greater in the thoracoscopy group than the subcostal closure group (6.9% in the subcostal closure group vs. 32.3% in the thoracoscopy group; p = 0.022). The subcostal closure technique is useful to prevent postthoracotomy pain syndrome. © The Author(s) 2016.

  16. 40 CFR 280.70 - Temporary closure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (UST) Out-of-Service UST Systems and Closure § 280.70 Temporary closure. (a) When an UST system is... the UST system is empty. The UST system is empty when all materials have been removed using commonly... the total capacity of the UST system, remain in the system. (b) When an UST system is temporarily...

  17. 40 CFR 280.70 - Temporary closure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (UST) Out-of-Service UST Systems and Closure § 280.70 Temporary closure. (a) When an UST system is... the UST system is empty. The UST system is empty when all materials have been removed using commonly... the total capacity of the UST system, remain in the system. (b) When an UST system is temporarily...

  18. 40 CFR 280.70 - Temporary closure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (UST) Out-of-Service UST Systems and Closure § 280.70 Temporary closure. (a) When an UST system is... the UST system is empty. The UST system is empty when all materials have been removed using commonly... the total capacity of the UST system, remain in the system. (b) When an UST system is temporarily...

  19. 40 CFR 280.70 - Temporary closure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (UST) Out-of-Service UST Systems and Closure § 280.70 Temporary closure. (a) When an UST system is... the UST system is empty. The UST system is empty when all materials have been removed using commonly... the total capacity of the UST system, remain in the system. (b) When an UST system is temporarily...

  20. 40 CFR 280.70 - Temporary closure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (UST) Out-of-Service UST Systems and Closure § 280.70 Temporary closure. (a) When an UST system is... the UST system is empty. The UST system is empty when all materials have been removed using commonly... the total capacity of the UST system, remain in the system. (b) When an UST system is temporarily...

  1. Near-wall effects for momentum, heat and mass transport in gas-particle suspensions at moderate Reynolds numbers

    NASA Astrophysics Data System (ADS)

    Radl, Stefan; Municchi, Federico; Goniva, Christoph

    2016-11-01

    Understanding transport phenomena in fluid-particle systems is of primary importance for the design of large-scale equipment, e.g., in the chemical industry. Typically, the analysis of such systems is performed by numerically solving a set of partial differential equations modeling the particle phase and the fluid phase as interpenetrating continua. Such models require a number of closure models that are often constructed via spatial filtering of data obtained from particle-resolved direct numerical simulations (PR-DNS). In the present work we make use of PR-DNS to evaluate corrections to existing closure models. Specifically, we aim on accounting for wall effects on the fluid-particle drag force and the particle-individual Nusselt number. We then propose an improved closure model to be used in particle-unresolved Euler-Lagrange (PU-EL) simulations. We demonstrate that such an advanced closure should account for a dimensionless filter size, as well as a normalized distance from the wall. In addition, we make an attempt to model the filtered fluid velocity profile in wall-bounded suspension flows. The authors acknowledge funding from the European Commission through FP7 Grant Agreement No. 604656, as well as VSC-3 and dcluster.tugraz.at.

  2. Construction of a wireless communication contact closure system for liquid chromatography with multiple parallel mass spectrometers and other detectors

    USDA-ARS?s Scientific Manuscript database

    A contact closure system has been constructed and implemented that utilizes two contact closure sender boards that communicate wirelessly to four contact closure receiver boards to distribute start signals from two or three liquid chromatographs to fourteen instruments, pumps, detectors, or other co...

  3. Practical operational implementation of Teton Pass avalanche monitoring infrasound system.

    DOT National Transportation Integrated Search

    2008-12-01

    Highway snow avalanche forecasting programs typically rely on weather and field observations to make road closure and hazard : evaluations. Recently, infrasonic avalanche monitoring technology has been developed for practical use near Teton Pass, WY ...

  4. Full closure strategic analysis.

    DOT National Transportation Integrated Search

    2014-07-01

    The full closure strategic analysis was conducted to create a decision process whereby full roadway : closures for construction and maintenance activities can be evaluated and approved or denied by CDOT : Traffic personnel. The study reviewed current...

  5. Evaluation of New Zealand’s High-Seas Bottom Trawl Closures Using Predictive Habitat Models and Quantitative Risk Assessment

    PubMed Central

    Penney, Andrew J.; Guinotte, John M.

    2013-01-01

    United Nations General Assembly Resolution 61/105 on sustainable fisheries (UNGA 2007) establishes three difficult questions for participants in high-seas bottom fisheries to answer: 1) Where are vulnerable marine systems (VMEs) likely to occur?; 2) What is the likelihood of fisheries interaction with these VMEs?; and 3) What might qualify as adequate conservation and management measures to prevent significant adverse impacts? This paper develops an approach to answering these questions for bottom trawling activities in the Convention Area of the South Pacific Regional Fisheries Management Organisation (SPRFMO) within a quantitative risk assessment and cost : benefit analysis framework. The predicted distribution of deep-sea corals from habitat suitability models is used to answer the first question. Distribution of historical bottom trawl effort is used to answer the second, with estimates of seabed areas swept by bottom trawlers being used to develop discounting factors for reduced biodiversity in previously fished areas. These are used in a quantitative ecological risk assessment approach to guide spatial protection planning to address the third question. The coral VME likelihood (average, discounted, predicted coral habitat suitability) of existing spatial closures implemented by New Zealand within the SPRFMO area is evaluated. Historical catch is used as a measure of cost to industry in a cost : benefit analysis of alternative spatial closure scenarios. Results indicate that current closures within the New Zealand SPRFMO area bottom trawl footprint are suboptimal for protection of VMEs. Examples of alternative trawl closure scenarios are provided to illustrate how the approach could be used to optimise protection of VMEs under chosen management objectives, balancing protection of VMEs against economic loss to commercial fishers from closure of historically fished areas. PMID:24358162

  6. Evaluation of New Zealand's high-seas bottom trawl closures using predictive habitat models and quantitative risk assessment.

    PubMed

    Penney, Andrew J; Guinotte, John M

    2013-01-01

    United Nations General Assembly Resolution 61/105 on sustainable fisheries (UNGA 2007) establishes three difficult questions for participants in high-seas bottom fisheries to answer: 1) Where are vulnerable marine systems (VMEs) likely to occur?; 2) What is the likelihood of fisheries interaction with these VMEs?; and 3) What might qualify as adequate conservation and management measures to prevent significant adverse impacts? This paper develops an approach to answering these questions for bottom trawling activities in the Convention Area of the South Pacific Regional Fisheries Management Organisation (SPRFMO) within a quantitative risk assessment and cost : benefit analysis framework. The predicted distribution of deep-sea corals from habitat suitability models is used to answer the first question. Distribution of historical bottom trawl effort is used to answer the second, with estimates of seabed areas swept by bottom trawlers being used to develop discounting factors for reduced biodiversity in previously fished areas. These are used in a quantitative ecological risk assessment approach to guide spatial protection planning to address the third question. The coral VME likelihood (average, discounted, predicted coral habitat suitability) of existing spatial closures implemented by New Zealand within the SPRFMO area is evaluated. Historical catch is used as a measure of cost to industry in a cost : benefit analysis of alternative spatial closure scenarios. Results indicate that current closures within the New Zealand SPRFMO area bottom trawl footprint are suboptimal for protection of VMEs. Examples of alternative trawl closure scenarios are provided to illustrate how the approach could be used to optimise protection of VMEs under chosen management objectives, balancing protection of VMEs against economic loss to commercial fishers from closure of historically fished areas.

  7. AN EVALUATION OF TWO GROUND-BASED CROWN CLOSURE ESTIMATION TECHNIQUES COMPARED TO CROWN CLOSURE ESTIMATES DERIVED FROM HIGH RESOLUTION IMAGERY

    EPA Science Inventory

    Two ground-based canopy closure estimation techniques, the Spherical Densitometer (SD) and the Vertical Tube (VT), were compared for the effect of deciduous understory on dominantlco-dominant crown closure estimates in even-aged loblolly (Pinus taeda) pine stands located in the N...

  8. AN EVALUATION OF TWO GROUND-BASED CROWN CLOSURE ESTIMATION TECHNIQUES COMPARED TO CROWN CLOSURE ESTIMATES DERIVED FROM HIGH RESOLUTION IMAGERY

    EPA Science Inventory

    Two ground-based canopy closure estimation techniques, the Spherical Densitometer (SD) and the Vertical Tube (VT), were compared for the effect of deciduous understory on dominant/co-dominant crown closure estimates in even-aged loblolly (Pinus taeda) pine stands located in the N...

  9. The Evaluator's Role in Recommending Program Closure: A Model for Decision Making and Professional Responsibility

    ERIC Educational Resources Information Center

    Eddy, Rebecca M.; Berry, Tiffany

    2009-01-01

    Evaluators face challenges when programs consistently fail to meet expectations for performance or improvement and consequently, evaluators may recommend that closing a program is the most prudent course of action. However, the evaluation literature provides little guidance regarding when an evaluator might recommend program closure. Given…

  10. Transcatheter closure of patent ductus arteriosus with severe pulmonary arterial hypertension in adults.

    PubMed

    Yan, C; Zhao, S; Jiang, S; Xu, Z; Huang, L; Zheng, H; Ling, J; Wang, C; Wu, W; Hu, H; Zhang, G; Ye, Z; Wang, H

    2007-04-01

    Surgical closure of patent ductus arteriosus (PDA) with severe pulmonary arterial hypertension in adults carries higher risk than in children. To investigate the application of self-expandable occluders for transcatheter closure of PDA associated with severe pulmonary arterial hypertension in adults, and the assessment of immediate and short-term results. 29 adult patients (6 men, 23 women) underwent attempted transcatheter closure of PDA at a mean (standard deviation (SD)) age of 31.1 (11.4) years (range 18-58 years) and a mean (SD) weight of 54.1 (7.1) kg (range 42-71 kg). On the basis of haemodynamic and clinical data obtained before and after trial occlusion, the final duct occlusion was determined and carried out. Radiographs of the chest, electrocardiograms and echocardiograms were used for follow-up evaluation of the treatment within 1 day, 1 month and 3-6 months after successful closure. 20 of the 29 patients had successful occlusion (group 1), and 9 patients failed (named group 2). In group 1, in which occlusion was successful, mean (SD) pulmonary arterial pressures decreased markedly after trial occlusion: 78 (19.3) mm Hg (range 50-125 mm Hg) before occlusion and 41 (13.8) mm Hg (range 23-77 mm Hg) after occlusion. Systemic arterial oxygen saturation was found to be >90% in 19 patients and <90% in the remaining patient before inhalation of oxygen, and >95% during inhalation of oxygen or after occlusion in all 20 patients. In group 2, the occlusion was not successful, because in two patients the device was not available; another two patients showed worsening of symptoms. The other five patients showed increased pulmonary arterial pressures after trial closure; their mean (SD) pulmonary arterial pressures increased by 10.3 (6) mm Hg (4-16 mm Hg) after trial occlusion, and systemic arterial oxygen saturation was 85.5% (2.6%) (range 82.6-88%) before inhalation of oxygen and 94.7% (1.7%) (range 90.7-99.1%) during inhalation of oxygen. In group 1, the dimensions of the left atrium, left ventricle and pulmonary artery increased considerably in 3-6-months of follow-up compared with those of preocclusion. Transcatheter closure is an effective treatment for adults with PDA associated with reversible severe pulmonary arterial hypertension. Further research is needed for the evaluation of long-term results.

  11. System Level Health Disparities in California Emergency Departments: Minorities and Medicaid Patients are at Higher Risk of Losing Their EDs

    PubMed Central

    Hsia, Renee Y.; Srebotnjak, Tanja; Kanzaria, Hemal K.; McCulloch, Charles; Auerbach, Andrew D.

    2015-01-01

    Study Objective Emergency Department (ED) closures threaten community access to emergency services, but few data exist to describe factors associated with closure. We evaluated factors associated with ED closure in California and sought to determine if hospitals serving more vulnerable populations have a higher rate of ED closure. Methods Retrospective cohort study of California hospital EDs between 1998 and 2008, using hospital and patient level data from the California Office of Statewide Planning and Development (OSHPD), as well as OSHPD Patient Discharge Data. We examined the effects of hospital and patient factors on the hospital's likelihood of ED closure using Cox proportional hazards models. Results In 4,411 hospital-years of observation, 29 of 401 (7.2%) EDs closed. In a model adjusted for total ED visits, hospital discharges, trauma center and teaching status, ownership, operating margin, and urbanicity, hospitals with more black patients (OR 1.41 per increase in proportion of blacks by 0.1, 95% CI 1.16-1.72) and Medi-Cal recipients (OR 1.17 per increase in proportion insured by Medi-Cal by 0.1, 95% CI 1.02-1.34) had higher odds for ED closure, as did for-profit institutions (OR 1.65, 95% CI 1.13-2.41). Conclusion The population served by EDs and hospitals’ profit model are associated with ED closure. Whether our findings are a manifestation of poorer reimbursement in at-risk EDs is unclear. PMID:22093435

  12. Closedure - Mine Closure Technologies Resource

    NASA Astrophysics Data System (ADS)

    Kauppila, Päivi; Kauppila, Tommi; Pasanen, Antti; Backnäs, Soile; Liisa Räisänen, Marja; Turunen, Kaisa; Karlsson, Teemu; Solismaa, Lauri; Hentinen, Kimmo

    2015-04-01

    Closure of mining operations is an essential part of the development of eco-efficient mining and the Green Mining concept in Finland to reduce the environmental footprint of mining. Closedure is a 2-year joint research project between Geological Survey of Finland and Technical Research Centre of Finland that aims at developing accessible tools and resources for planning, executing and monitoring mine closure. The main outcome of the Closedure project is an updatable wiki technology-based internet platform (http://mineclosure.gtk.fi) in which comprehensive guidance on the mine closure is provided and main methods and technologies related to mine closure are evaluated. Closedure also provides new data on the key issues of mine closure, such as performance of passive water treatment in Finland, applicability of test methods for evaluating cover structures for mining wastes, prediction of water effluents from mine wastes, and isotopic and geophysical methods to recognize contaminant transport paths in crystalline bedrock.

  13. 40 CFR 281.36 - Out-of-service UST systems and closure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Out-of-service UST systems and closure... § 281.36 Out-of-service UST systems and closure. In order to be considered no less stringent than the... and corrective action requirements must be complied with. (c) All UST systems taken out of service...

  14. 40 CFR 281.36 - Out-of-service UST systems and closure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Out-of-service UST systems and closure... § 281.36 Out-of-service UST systems and closure. In order to be considered no less stringent than the... and corrective action requirements must be complied with. (c) All UST systems taken out of service...

  15. 40 CFR 281.36 - Out-of-service UST systems and closure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Out-of-service UST systems and closure... § 281.36 Out-of-service UST systems and closure. In order to be considered no less stringent than the... and corrective action requirements must be complied with. (c) All UST systems taken out of service...

  16. 40 CFR 281.36 - Out-of-service UST systems and closure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Out-of-service UST systems and closure... § 281.36 Out-of-service UST systems and closure. In order to be considered no less stringent than the... and corrective action requirements must be complied with. (c) All UST systems taken out of service...

  17. 40 CFR 281.36 - Out-of-service UST systems and closure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Out-of-service UST systems and closure... § 281.36 Out-of-service UST systems and closure. In order to be considered no less stringent than the... and corrective action requirements must be complied with. (c) All UST systems taken out of service...

  18. 77 FR 19055 - Morgan Olson, LLC, Receipt of Petition for Decision of Inconsequential Noncompliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-29

    ... noncompliance is that the affected vehicles do not contain a primary door latch system or door closure warning... for either a primary door latch system or door closure warning system applied only to its vehicles... latched position. Nor are these vehicles equipped with a door closure warning system. Rule text: Paragraph...

  19. CELSS Transportation Analysis

    NASA Technical Reports Server (NTRS)

    Olson, R. L.; Gustan, E. A.; Vinopal, T. J.

    1985-01-01

    Regenerative life support systems based on the use of biological material was considered for inclusion in manned spacecraft. Biological life support systems are developed in the controlled ecological life support system (CELSS) program. Because of the progress achieved in the CELSS program, it is determined which space missions may profit from use of the developing technology. Potential transportation cost savings by using CELSS technology for selected future manned space missions was evaluated. Six representative missions were selected which ranged from a low Earth orbit mission to those associated with asteroids and a Mars sortie. The crew sizes considered varied from four persons to five thousand. Other study parameters included mission duration and life support closure percentages, with the latter ranging from complete resupply of consumable life support materials to 97% closure of the life support system. The analytical study approach and the missions and systems considered, together with the benefits derived from CELSS when applicable are described.

  20. Endoscopic closure of persistent gastrocutaneous fistulae, after percutaneous endoscopic gastrostomy (PEG) tube placement, using the over-the-scope-clip system

    PubMed Central

    Changela, Kinesh; Culliford, Andrea; Duddempudi, Sushil; Krishnaiah, Mahesh; Anand, Sury

    2015-01-01

    Objectives: The Over-The-Scope-Clip (OTSC) has had an evolving role in endoscopic closure of gastrointestinal wall defects, in hemostasis of primary or postinterventional bleeding, and approximation of postbariatric surgery defects. Rapid and effective closure of gastrocutaneous (GC) fistulae using this device has been recently described in the literature. The aim of this study was to evaluate the technical feasibility, efficacy and safety of OTSC as an effective tool in the management of persistent GC fistulae secondary to a complication of percutaneous endoscopic gastrostomy (PEG) tube placement. Method: In this multicenter prospective observational study, we describe our experience with OTSC in the closure of persistent GC fistulas secondary to PEG tube placement. Patients with GC fistulas were sequentially enrolled with a mean age of 84 years. Primary treatment outcome was the immediate successful closure of GC fistula and resolution of leak. Secondary outcome was no recurrence of the fistula and leaks on follow up. Results: A total of 10 patients were enrolled over the study period. Mean age was 84.4 ± 8.75 years. The primary treatment outcome was achieved in all the patients undergoing this intervention. Secondary outcome was observed in 9/10 (90%) subjects. No procedural complications were reported. Larger fistulae (>2.5 cm) and those with significant fibrosis were more difficult to close with the OTSC system. The mean follow-up time after OTSC application was 43.7 ± 20.57 days. A limitation of this study was that there was no control group. Conclusions: OTSC application is a safe and effective endoscopic approach for the closure of persistent GC fistulae secondary to a complication of PEG tube placement. PMID:26136836

  1. Endoscopic closure of persistent gastrocutaneous fistulae, after percutaneous endoscopic gastrostomy (PEG) tube placement, using the over-the-scope-clip system.

    PubMed

    Singhal, Shashideep; Changela, Kinesh; Culliford, Andrea; Duddempudi, Sushil; Krishnaiah, Mahesh; Anand, Sury

    2015-07-01

    The Over-The-Scope-Clip (OTSC) has had an evolving role in endoscopic closure of gastrointestinal wall defects, in hemostasis of primary or postinterventional bleeding, and approximation of postbariatric surgery defects. Rapid and effective closure of gastrocutaneous (GC) fistulae using this device has been recently described in the literature. The aim of this study was to evaluate the technical feasibility, efficacy and safety of OTSC as an effective tool in the management of persistent GC fistulae secondary to a complication of percutaneous endoscopic gastrostomy (PEG) tube placement. In this multicenter prospective observational study, we describe our experience with OTSC in the closure of persistent GC fistulas secondary to PEG tube placement. Patients with GC fistulas were sequentially enrolled with a mean age of 84 years. Primary treatment outcome was the immediate successful closure of GC fistula and resolution of leak. Secondary outcome was no recurrence of the fistula and leaks on follow up. A total of 10 patients were enrolled over the study period. Mean age was 84.4 ± 8.75 years. The primary treatment outcome was achieved in all the patients undergoing this intervention. Secondary outcome was observed in 9/10 (90%) subjects. No procedural complications were reported. Larger fistulae (>2.5 cm) and those with significant fibrosis were more difficult to close with the OTSC system. The mean follow-up time after OTSC application was 43.7 ± 20.57 days. A limitation of this study was that there was no control group. OTSC application is a safe and effective endoscopic approach for the closure of persistent GC fistulae secondary to a complication of PEG tube placement.

  2. Online Student Evaluation Improves Course Experience Questionnaire Results in a Physiotherapy Program

    ERIC Educational Resources Information Center

    Tucker, Beatrice; Jones, Sue; Straker, Leon

    2008-01-01

    This paper reports the use of an online student evaluation system, Course Experience on the Web (CEW), in a physiotherapy program to improve their Course Experience Questionnaire (CEQ) results. CEW comprises a course survey instrument modeled on the CEQ and a tailored unit survey instrument. Closure of the feedback loop is integral in the CEW…

  3. Trial occlusion to assess the risk of persistent pulmonary arterial hypertension after closure of a large patent ductus arteriosus in adolescents and adults with elevated pulmonary artery pressure.

    PubMed

    Zhang, Duan-Zhen; Zhu, Xian-Yang; Lv, Bei; Cui, Chun-Sheng; Han, Xiu-Min; Sheng, Xiao-Tang; Wang, Qi-Guang; Zhang, Po

    2014-08-01

    No method is available to predict whether patients with patent ductus arteriosus (PDA) and severe pulmonary arterial hypertension (PAH) will show persistent postprocedural PAH (PP-PAH) after PDA closure. This study evaluated the usefulness of trial occlusion for predicting PP-PAH after transcatheter PDA closure in patients with severe PAH. Trial occlusion was performed in 137 patients (age ≥12 years) with PDA and severe PAH. All patients undergoing trial occlusion had a mean pulmonary artery pressure ≥45 mm Hg, pulmonary:systemic flow (Qp/Qs) ratio >1.5, and pulmonary:systemic resistance (Rp/Rs) ratio <0.7. A total of 135 patients (98%) showing stable hemodynamics during occlusion trial underwent successful device closure. Linear correlation analysis revealed weak or moderate relationships between the baseline and post-trial pulmonary artery pressures and pulmonary:systemic pressure (Pp/Ps) ratios. Patients were followed up for 1 to 10 years (median: 5 years). PP-PAH (systolic pulmonary artery pressure >50 mm Hg by Doppler echocardiography) was detected in 17 patients (13%), who displayed no significant differences in sex and age compared with patients without PP-PAH. According to discriminant analysis, the strongest discriminators between patients with and without PP-PAH were the baseline left ventricular end-diastolic volume and the baseline and post-trial systolic Pp/Ps ratios. In particular, a post-trial systolic Pp/Ps ratio >0.5 correctly classified 100% of the PP-PAH and non-PAH patients. Trial occlusion is a feasible method to predict PP-PAH in patients with PDA and severe PAH. A post-trial systolic Pp/Ps ratio >0.5 indicates a high risk of PP-PAH occurrence after device closure. © 2014 American Heart Association, Inc.

  4. Closure of skin incisions in rabbits by laser soldering: I: Wound healing pattern.

    PubMed

    Simhon, David; Brosh, Tamar; Halpern, Marisa; Ravid, Avi; Vasilyev, Tamar; Kariv, Naam; Katzir, Abraham; Nevo, Zvi

    2004-01-01

    Temperature-controlled tissue laser soldering is an innovative sutureless technique awaiting only solid experimental data to become the gold-standard surgical procedure for incision closure. The goals of the current study were: (1) to define the optimal laser soldering conditions, (2) to explore the immediate skin reparative healing events after sealing the wound, and (3) to determine the long-term trajectory of skin wound healing. Skin incisions were generated over rabbit dorsa and were closed using different wound-closure interventions, in three groups: (a) closure, using a temperature-controlled infrared fiberoptic CO2 laser system, employing 47% bovine serum albumin as a solder; (b) wound closure by cyanoacrylate glues; and (c) wound closure by sutures. The reparative outcomes were evaluated macroscopically and microscopically, employing semi-quantitative grading indices. Laser soldering of incisions at T = 65 degrees C emerged as the optimal method achieving immediate wound sealing. This in turn induced accelerated reparative events characterized by a reduced inflammatory reaction, followed by minimal scarring and leading to a fine quality healing. Temperature-controlled laser soldering offers an accelerated wound reparative process with numerous advantages over the conventional methods. Further investigations may reveal additional benefits in the spectrum of advantages that this innovative surgical technology has to offer. This can introduce new scientific insight that will pave the way for clinical use.

  5. Study design of the CLOSURE I Trial: a prospective, multicenter, randomized, controlled trial to evaluate the safety and efficacy of the STARFlex septal closure system versus best medical therapy in patients with stroke or transient ischemic attack due to presumed paradoxical embolism through a patent foramen ovale.

    PubMed

    Furlan, Anthony J; Reisman, Mark; Massaro, Joseph; Mauri, Laura; Adams, Harold; Albers, Gregory W; Felberg, Robert; Herrmann, Howard; Kar, Saibal; Landzberg, Michael; Raizner, Albert; Wechsler, Lawrence

    2010-12-01

    Some strokes of unknown etiology may be the result of a paradoxical embolism traversing through a nonfused foramen ovale (patent foramen ovale [PFO]). The utility of percutaneously placed devices for treatment of patients with cryptogenic stroke or transient ischemic attack (TIA) and PFO is unknown. In addition, there are no clear data about the utility of medical interventions or other surgical procedures in this situation. Despite limited data, many patients are being treated with PFO closure devices. Thus, there is a strong need for clinical trials that test the potential efficacy of PFO occlusive devices in this situation. To address this gap in medical knowledge, we designed the CLOSURE I trial, a randomized, clinical trial comparing the use of a percutaneously placed PFO occlusive device and best medical therapy versus best medical therapy alone for prevention of recurrent ischemic neurologic symptoms among persons with TIA or ischemic stroke. This prospective, multicenter, randomized, controlled trial has finished enrollment. Two-year follow-up for all 910 patients is required. The primary end point is the 2-year incidence of stroke or TIA, all-cause mortality for the first 30 days, and neurologic mortality from ≥ 31 days of follow-up, as adjudicated by a panel of physicians who are unaware of treatment allocation. This article describes the rationale and study design of CLOSURE I. This trial should provide information as to whether the STARFlex septal closure system is safe and more effective than best medical therapy alone in preventing recurrent stroke/TIA and mortality in patients with PFO and whether the STARFlex septal closure device can demonstrate superiority compared with best medical therapy alone. Clinical Trial Registration-URL: http://www.clinicaltrials.gov. Unique identifier: NCT00201461.

  6. Echocardiographic evaluation of myocardial changes observed after closure of patent ductus arteriosus in dogs.

    PubMed

    Hamabe, L; Kim, S; Yoshiyuki, R; Fukayama, T; Nakata, T M; Fukushima, R; Tanaka, R

    2015-01-01

    Closure of PDA can be associated with echocardiographic changes including deterioration of LV systolic function. Although PDA is commonly encountered in dogs, few comprehensive reports of echocardiographic changes in dogs with PDA closure are available. To evaluate the short-term echocardiographic changes observed after PDA closure in dogs using strain analysis. Seventeen client-owned dogs with left-to-right PDA. Echocardiographic evaluations, including standard echocardiography and two-dimensional tissue tracking (2DTT), were performed before and within 3 days of PDA closure. Preclosure examination showed LV and left atrial dilatation indicating volume overload as a result of PDA. Closure of PDA resulted in significant reduction of LVIDd (<.0001) and LA/Ao (0.01) without change in LVIDs, suggestive of decreased preload. Postclosure LV systolic dysfunction was observed with significant decreased in FS (<.0001) and strain values (P = .0039 for radial strains, P = .0005 for circumferential strains). Additionally, significant LV dyssynchrony (P = .0162) was observed after closure of PDA. Closure of PDA resulted in decreased preload as a result of alleviation of LV volume overload, which in turn caused transient deterioration of LV systolic function. Additionally, this study demonstrated that strain analysis is load dependent. Therefore, care should be taken when interpreting strain measurements as an indicator of LV systolic function. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of American College of Veterinary Internal Medicine.

  7. UV fluorescence excitation imaging of healing of wounds in skin: Evaluation of wound closure in organ culture model.

    PubMed

    Wang, Ying; Gutierrez-Herrera, Enoch; Ortega-Martinez, Antonio; Anderson, Richard Rox; Franco, Walfre

    2016-09-01

    Molecules native to tissue that fluoresce upon light excitation can serve as reporters of cellular activity and protein structure. In skin, the fluorescence ascribed to tryptophan is a marker of cellular proliferation, whereas the fluorescence ascribed to cross-links of collagen is a structural marker. In this work, we introduce and demonstrate a simple but robust optical method to image the functional process of epithelialization and the exposed dermal collagen in wound healing of human skin in an organ culture model. Non-closing non-grafted, partial closing non-grafted, and grafted wounds were created in ex vivo human skin and kept in culture. A wide-field UV fluorescence excitation imaging system was used to visualize epithelialization of the exposed dermis and quantitate wound area, closure, and gap. Histology (H&E staining) was also used to evaluate epithelialization. The endogenous fluorescence excitation of cross-links of collagen at 335 nm clearly shows the dermis missing epithelium, while the endogenous fluorescence excitation of tryptophan at 295 nm shows keratinocytes in higher proliferating state. The size of the non-closing wound was 11.4 ± 1.8 mm and remained constant during the observation period, while the partial-close wound reached 65.5 ± 4.9% closure by day 16. Evaluations of wound gaps using fluorescence excitation images and histology images are in agreement. We have established a fluorescence imaging method for studying epithelialization processes, evaluating keratinocyte proliferation, and quantitating closure during wound healing of skin in an organ culture model: the dermal fluorescence of pepsin-digestible collagen cross-links can be used to quantitate wound size, closure extents, and gaps; and, the epidermal fluorescence ascribed to tryptophan can be used to monitor and quantitate functional states of epithelialization. UV fluorescence excitation imaging has the potential to become a valuable tool for research, diagnostic and educational purposes on evaluating the healing of wounds. Lasers Surg. Med. 48:678-685, 2016. © 2016 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc. © 2016 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.

  8. The Grell-Freitas Convection Parameterization: Recent Developments and Applications Within the NASA GEOS Global Model

    NASA Technical Reports Server (NTRS)

    Freitas, Saulo R.; Grell, Georg; Molod, Andrea; Thompson, Matthew A.

    2017-01-01

    We implemented and began to evaluate an alternative convection parameterization for the NASA Goddard Earth Observing System (GEOS) global model. The parameterization is based on the mass flux approach with several closures, for equilibrium and non-equilibrium convection, and includes scale and aerosol awareness functionalities. Recently, the scheme has been extended to a tri-modal spectral size approach to simulate the transition from shallow, mid, and deep convection regimes. In addition, the inclusion of a new closure for non-equilibrium convection resulted in a substantial gain of realism in model simulation of the diurnal cycle of convection over the land. Here, we briefly introduce the recent developments, implementation, and preliminary results of this parameterization in the NASA GEOS modeling system.

  9. Evaluation of left ventricular function by tissue Doppler and speckle-derived strain rate echocardiography after percutaneous ductus closure.

    PubMed

    Amoogzar, Hamid; Shakiba, Ali Mohammad; Derakhshan, Dorna; Ajami, Gholamhossein; Cheriki, Sirous; Borzouee, Mohammad; Edraki, Mohammad Reza; Mehdizadegan, Nima

    2015-01-01

    The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P < 0.05). After 1 month, both improved significantly; ultimately, after 1 month no change was observed in systolic function measures compared with the pre-closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P < 0.05). Both early tissue Doppler early velocity of lateral mitral annulus (E'M) and early to late velocity ratio (E'M/A'M) of lateral mitral annulus decreased significantly (P = 0.02) in early post-closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P < 0.001 for both occasions). Global and segmental longitudinal strain measures reduced significantly early after PDA closure (P < 0.05) but it improved remarkably in the subsequent month. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.

  10. 38 CFR 4.79 - Schedule of ratings-eye.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... retina. 6009Unhealed eye injury. General Rating Formula for Diagnostic Codes 6000 through 6009 Evaluate... irregularities, if this would result in a higher evaluation. 6012Angle-closure glaucoma: Evaluate on the basis of either visual impairment due to angle-closure glaucoma or incapacitating episodes, whichever results in a...

  11. 38 CFR 4.79 - Schedule of ratings-eye.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... retina. 6009Unhealed eye injury. General Rating Formula for Diagnostic Codes 6000 through 6009 Evaluate... irregularities, if this would result in a higher evaluation. 6012Angle-closure glaucoma: Evaluate on the basis of either visual impairment due to angle-closure glaucoma or incapacitating episodes, whichever results in a...

  12. 38 CFR 4.79 - Schedule of ratings-eye.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... retina. 6009Unhealed eye injury. General Rating Formula for Diagnostic Codes 6000 through 6009 Evaluate... irregularities, if this would result in a higher evaluation. 6012Angle-closure glaucoma: Evaluate on the basis of either visual impairment due to angle-closure glaucoma or incapacitating episodes, whichever results in a...

  13. Two consecutive microtubule-based epithelial seaming events mediate dorsal closure in the scuttle fly Megaselia abdita.

    PubMed

    Fraire-Zamora, Juan Jose; Jaeger, Johannes; Solon, Jérôme

    2018-03-14

    Evolution of morphogenesis is generally associated with changes in genetic regulation. Here, we report evidence indicating that dorsal closure, a conserved morphogenetic process in dipterans, evolved as the consequence of rearrangements in epithelial organization rather than signaling regulation. In Drosophila melanogaster , dorsal closure consists of a two-tissue system where the contraction of extraembryonic amnioserosa and a JNK/Dpp-dependent epidermal actomyosin cable result in microtubule-dependent seaming of the epidermis. We find that dorsal closure in Megaselia abdita, a three-tissue system comprising serosa, amnion and epidermis, differs in morphogenetic rearrangements despite conservation of JNK/Dpp signaling. In addition to an actomyosin cable, M. abdita dorsal closure is driven by the rupture and contraction of the serosa and the consecutive microtubule-dependent seaming of amnion and epidermis. Our study indicates that the evolutionary transition to a reduced system of dorsal closure involves simplification of the seaming process without changing the signaling pathways of closure progression. © 2018, Fraire-Zamora et al.

  14. Two consecutive microtubule-based epithelial seaming events mediate dorsal closure in the scuttle fly Megaselia abdita

    PubMed Central

    Jaeger, Johannes

    2018-01-01

    Evolution of morphogenesis is generally associated with changes in genetic regulation. Here, we report evidence indicating that dorsal closure, a conserved morphogenetic process in dipterans, evolved as the consequence of rearrangements in epithelial organization rather than signaling regulation. In Drosophila melanogaster, dorsal closure consists of a two-tissue system where the contraction of extraembryonic amnioserosa and a JNK/Dpp-dependent epidermal actomyosin cable result in microtubule-dependent seaming of the epidermis. We find that dorsal closure in Megaselia abdita, a three-tissue system comprising serosa, amnion and epidermis, differs in morphogenetic rearrangements despite conservation of JNK/Dpp signaling. In addition to an actomyosin cable, M. abdita dorsal closure is driven by the rupture and contraction of the serosa and the consecutive microtubule-dependent seaming of amnion and epidermis. Our study indicates that the evolutionary transition to a reduced system of dorsal closure involves simplification of the seaming process without changing the signaling pathways of closure progression. PMID:29537962

  15. Pore formation and pore closure in poly(D,L-lactide-co-glycolide) films.

    PubMed

    Fredenberg, Susanne; Wahlgren, Marie; Reslow, Mats; Axelsson, Anders

    2011-03-10

    Pore formation and pore closure in poly(D,L-lactide-co-glycolide)-based drug delivery systems are two important processes as they control the release of the encapsulated drug. The phenomenon pore closure was investigated by studying the effects of the pH and the temperature of the release medium, and the properties of the polymer. Poly(D,L-lactide-co-glycolide) (PLG) films were subjected to a pore forming pre-treatment, and then pore closure was observed simultaneously with changes in glass transition temperature, wettability (contact angle), water absorption and mass remaining. To further understand the effect of pH, combined pore formation and pore closure were studied at different pH values. Pore closure was increased in a release medium with low pH, with a low-molecular-weight PLG of relatively low degree of hydrophobicity, or at high temperature. Pore closure occurred by two different mechanisms, one based on polymer-polymer interactions and one on polymer-water interactions. The mobility of the PLG chains also played an important role. The surface of the PLG films were more porous at pH 5-6 than at lower or higher pH, as pore formation was relatively fast and pore closure were less pronounced in this pH range. The pH had a significant impact on the porous structure, which should be kept in mind when evaluating experimental results, as the pH may be significantly decreased in vitro, in vivo and in situ. The results also show that the initial porosity is very important when using a high-molecular-weight PLG. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Comparison of EyeCam and anterior segment optical coherence tomography in detecting angle closure.

    PubMed

    Baskaran, Mani; Aung, Tin; Friedman, David S; Tun, Tin A; Perera, Shamira A

    2012-12-01

    To compare the diagnostic performance of EyeCam (Clarity Medical Systems, Pleasanton, CA, USA) and anterior segment optical coherence tomography (ASOCT, Visante; Carl Zeiss Meditec, Dublin, CA, USA) in detecting angle closure, using gonioscopy as the reference standard. Ninety-eight phakic patients, recruited from a glaucoma clinic, underwent gonioscopy by a single examiner, and EyeCam and ASOCT imaging by another examiner. Another observer, masked to gonioscopy findings, graded EyeCam and ASOCT images. For both gonioscopy and EyeCam, a closed angle in a particular quadrant was defined if the posterior trabecular meshwork was not visible. For ASOCT, angle closure was defined by any contact between the iris and angle anterior to the scleral spur. An eye was diagnosed as having angle closure if ≥2 quadrants were closed. Agreement and area under the receiver operating characteristic curves (AUC) were evaluated. The majority of subjects were Chinese (69/98, 70.4%) with a mean age of 60.6 years. Angle closure was diagnosed in 39/98 (39.8%) eyes with gonioscopy, 40/98 (40.8%) with EyeCam and 56/97 (57.7%) with ASOCT. The agreement (kappa statistic) for angle closure diagnosis for gonioscopy versus EyeCam was 0.89; gonioscopy versus ASOCT and EyeCam versus ASOCT were both 0.56. The AUC for detecting eyes with gonioscopic angle closure with EyeCam was 0.978 (95% CI: 0.93-1.0) and 0.847 (95% CI: 0.76-0.92, p < 0.01) for ASOCT. The diagnostic performance of EyeCam was better than ASOCT in detecting angle closure when gonioscopic grading was used as the reference standard. The agreement between the two imaging modalities was moderate. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  17. Environmental Assessment for the Closure of the High-Level Waste Tanks in F- & H-Areas at the Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    N /A

    1996-07-31

    This Environmental Assessment (EA) has been prepared by the Department of Energy (DOE) to assess the potential environmental impacts associated with the closure of 51 high-level radioactive waste tanks and tank farm ancillary equipment (including transfer lines, evaporators, filters, pumps, etc) at the Savannah River Site (SRS) located near Aiken, South Carolina. The waste tanks are located in the F- and H-Areas of SRS and vary in capacity from 2,839,059 liters (750,000 gallons) to 4,921,035 liters (1,300,000 gallons). These in-ground tanks are surrounded by soil to provide shielding. The F- and H-Area High-Level Waste Tanks are operated under the authoritymore » of Industrial Wastewater Permits No.17,424-IW; No.14520, and No.14338 issued by the South Carolina Department of Health and Environmental Control (SCDHEC). In accordance with the Permit requirements, DOE has prepared a Closure Plan (DOE, 1996) and submitted it to SCDHEC for approval. The Closure Plan identifies all applicable or relevant and appropriate regulations, statutes, and DOE Orders for closing systems operated under the Industrial Wastewater Permits. When approved by SCDHEC, the Closure Plan will present the regulatory process for closing all of the F- and H-Area High Level Waste Tanks. The Closure Plan establishes performance objectives or criteria to be met prior to closing any tank, group of tanks, or ancillary tank farm equipment. The proposed action is to remove the residual wastes from the tanks and to fill the tanks with a material to prevent future collapse and bind up residual waste, to lower human health risks, and to increase safety in and around the tanks. If required, an engineered cap consisting of clay, backfill (soil), and vegetation as the final layer to prevent erosion would be applied over the tanks. The selection of tank system closure method will be evaluated against the following Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) criteria described in 40 CFR 300.430(e)(9): ( 1) overall protection of human health and the environment; (2) compliance with applicable or relevant and appropriated requirement: (ARARs); (3) long-term effectiveness and permanence; (4) reduction of toxicity, mobility, or volume through treatment; (5) short-term effectiveness; (6) implementability; (7) cost; (8) state acceptable; and (9) community acceptance. Closure of each tank involves two separate operations after bulk waste removal has been accomplished: (1) cleaning of the tank (i.e., removing the residual contaminants), and (2) the actual closure or filling of the tank with an inert material, (e.g., grout). This process would continue until all the tanks and ancillary equipment and systems have been closed. This is expected to be about year 2028 for Type I, II, and IV tanks and associated systems. Subsequent to that, Type III tanks and systems will be closed.« less

  18. 75 FR 28655 - Rexam Closure Systems, Inc. a Subsidiary of Rexam PLC Including On-Site Leased Workers From...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-21

    ..., Inc. a Subsidiary of Rexam PLC Including On-Site Leased Workers From Addeco Employment Services..., applicable to the workers of Rexam Closure Systems, Inc., a subsidiary of Rexam PLC, Hamlet, North Carolina... Rexam Closure Systems, Inc., a subsidiary of Rexam PLC purchased Owens Illinois Manufacturing. Some...

  19. Influence of glottal closure configuration on vocal efficacy in young normal-speaking women.

    PubMed

    Schneider, Berit; Bigenzahn, Wolfgang

    2003-12-01

    Posterior closure insufficiency of the glottis is often mentioned in connection with permanent voice disorders. Recently published studies have revealed that an incomplete closure of the glottis can be found also in normal-speaking voices, especially in women. However, the effect of glottal closure configuration on vocal efficacy is not sufficiently clarified. The purpose of this study was to determine the effect of glottal closure configuration on singing and speaking voice characteristics. Overall, 520 young female normal-speaking subjects were examined by videostroboscopy for different phonation conditions in the combination of soft, loud, low, and/or high phonation and by voice range profile measurements. According to the videostroboscopic analysis, the subjects were subdivided into four groups: complete closure of the vocal folds already in soft phonation (group 1), closure of the vocal fold with increasing intensity (group 2), persistent closure insufficiencies despite increasing intensity (group 3), and hourglass-shaped closure in subjects with vocal nodules (group 4). Subjects in which the glottal closure could not be evaluated sufficiently were subclassified into group 5 (missing values). Selected criteria of the singing and speaking voice were evaluated and statistically processed according to the mentioned subclassification. Group 1 reached significantly the highest sound pressure levels (SPLmax) for the singing voice as well as for the shouting voice. Group 3 showed a limited capacity to increase the intensity of the singing and speaking voice. The results gathered in this study objectify the relationship of insufficient glottal closure and reduced vocal capabilities. As long as no conclusive data on long-term consequences of insufficient glottal closure are available, a prophylactic improvement of the laryngeal situation especially in female professional voice users by voice therapy should be recommended.

  20. Corrective Action Decision Document/Corrective Action Plan for the 92-Acre Area and Corrective Action Unit 111: Area 5 WMD Retired Mixed Waste Pits, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    This Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) has been prepared for the 92-Acre Area, the southeast quadrant of the Radioactive Waste Management Site, located in Area 5 of the Nevada National Security Site (NNSS). The 92-Acre Area includes Corrective Action Unit (CAU) 111, 'Area 5 WMD Retired Mixed Waste Pits.' Data Quality Objectives (DQOs) were developed for the 92-Acre Area, which includes CAU 111. The result of the DQO process was that the 92-Acre Area is sufficiently characterized to provide the input data necessary to evaluate corrective action alternatives (CAAs) without the collection of additional data. The DQOs aremore » included as Appendix A of this document. This CADD/CAP identifies and provides the rationale for the recommended CAA for the 92-Acre Area, provides the plan for implementing the CAA, and details the post-closure plan. When approved, this CADD/CAP will supersede the existing Pit 3 (P03) Closure Plan, which was developed in accordance with Title 40 Code of Federal Regulations (CFR) Part 265, 'Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities.' This document will also serve as the Closure Plan and the Post-Closure Plan, which are required by 40 CFR 265, for the 92-Acre Area. After closure activities are complete, a request for the modification of the Resource Conservation and Recovery Act Permit that governs waste management activities at the NNSS will be submitted to the Nevada Division of Environmental Protection to incorporate the requirements for post-closure monitoring. Four CAAs, ranging from No Further Action to Clean Closure, were evaluated for the 92-Acre Area. The CAAs were evaluated on technical merit focusing on performance, reliability, feasibility, safety, and cost. Based on the evaluation of the data used to develop the conceptual site model; a review of past, current, and future operations at the site; and the detailed and comparative analysis of the potential CAAs, Closure in Place with Administrative Controls is the preferred CAA for the 92-Acre Area. Closure activities will include the following: (1) Constructing an engineered evapotranspiration cover over the 92-Acre Area; (2) Installing use restriction (UR) warning signs, concrete monuments, and subsidence survey monuments; (3) Establishing vegetation on the cover; (4) Implementing a UR; and (5) Implementing post-closure inspections and monitoring. The Closure in Place with Administrative Controls alternative meets all requirements for the technical components evaluated, fulfills all applicable federal and state regulations for closure of the site, and will minimize potential future exposure pathways to the buried waste at the site.« less

  1. Corrective Action Decision Document/Corrective Action Plan for the 92-Acre Area and Corrective Action Unit 111: Area 5 WMD Retired Mixed Waste Pits, Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2009-07-31

    This Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) has been prepared for the 92-Acre Area, the southeast quadrant of the Radioactive Waste Management Site, located in Area 5 of the Nevada Test Site (NTS). The 92-Acre Area includes Corrective Action Unit (CAU) 111, 'Area 5 WMD Retired Mixed Waste Pits.' Data Quality Objectives (DQOs) were developed for the 92-Acre Area, which includes CAU 111. The result of the DQO process was that the 92-Acre Area is sufficiently characterized to provide the input data necessary to evaluate corrective action alternatives (CAAs) without the collection of additional data. The DQOs are includedmore » as Appendix A of this document. This CADD/CAP identifies and provides the rationale for the recommended CAA for the 92-Acre Area, provides the plan for implementing the CAA, and details the post-closure plan. When approved, this CADD/CAP will supersede the existing Pit 3 (P03) Closure Plan, which was developed in accordance with Title 40 Code of Federal Regulations (CFR) Part 265, 'Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities.' This document will also serve as the Closure Plan and the Post-Closure Plan, which are required by 40 CFR 265, for the 92-Acre Area. After closure activities are complete, a request for the modification of the Resource Conservation and Recovery Act Permit that governs waste management activities at the NTS will be submitted to the Nevada Division of Environmental Protection to incorporate the requirements for post-closure monitoring. Four CAAs, ranging from No Further Action to Clean Closure, were evaluated for the 92-Acre Area. The CAAs were evaluated on technical merit focusing on performance, reliability, feasibility, safety, and cost. Based on the evaluation of the data used to develop the conceptual site model; a review of past, current, and future operations at the site; and the detailed and comparative analysis of the potential CAAs, Closure in Place with Administrative Controls is the preferred CAA for the 92-Acre Area. Closure activities will include the following: (1) Constructing an engineered evapotranspiration cover over the 92-Acre Area; (2) Installing use restriction (UR) warning signs, concrete monuments, and subsidence survey monuments; (3) Establishing vegetation on the cover; (4) Implementing a UR; and (5) Implementing post-closure inspections and monitoring. The Closure in Place with Administrative Controls alternative meets all requirements for the technical components evaluated, fulfills all applicable federal and state regulations for closure of the site, and will minimize potential future exposure pathways to the buried waste at the site.« less

  2. Substantial Impact of School Closure on the Transmission Dynamics during the Pandemic Flu H1N1-2009 in Oita, Japan

    PubMed Central

    2015-01-01

    Background School closure is considered as an effective measure to prevent pandemic influenza. Although Japan has implemented many class, grade, and whole school closures during the early stage of the pandemic 2009, the effectiveness of such a school closure has not been analysed appropriately. In addition, analysis based on evidence or data from a large population has yet to be performed. We evaluated the preventive effect of school closure against the pandemic (H1N1) 2009 and examined efficient strategies of reactive school closure. Materials and Methods Data included daily reports of reactive school closures and the number of infected students in the pandemic in Oita City, Japan. We used a regression model that incorporated a time delay to analyse the daily data of school closure based on a time continuous susceptible-exposed-infected-removed model of infectious disease spread. The delay was due to the time-lag from transmission to case reporting. We simulated the number of students infected daily with and without school closure and evaluated the effectiveness. Results The model with a 3-day delay from transmission to reporting yielded the best fit using R 2 (the coefficient of determination). This result suggests that the recommended period of school closure is more than 4 days. Moreover, the effect of school closure in the simulation of school closure showed the following: the number of infected students decreased by about 24% at its peak, and the number of cumulative infected students decreased by about 8.0%. Conclusions School closure was an effective intervention for mitigating the spread of influenza and should be implemented for more than 4 days. School closure has a remarkable impact on decreasing the number of infected students at the peak, but it does not substantially decrease the total number of infected students. PMID:26669757

  3. Comparison of cost-effectiveness and postoperative outcome of device closure and open surgery closure techniques for treatment of patent ductus arteriosus.

    PubMed

    Ahmadi, Alireza; Sabri, Mohammadreza; Bigdelian, Hamid; Dehghan, Bahar; Gharipour, Mojgan

    2014-01-01

    Various devices have been recently employed for percutaneous closure of the patent ductus arteriosus (PDA). Although the high effectiveness of device closure techniques has been clearly determined, a few studies have focused on the cost-effectiveness and also postoperative complications of these procedures in comparison with open surgery. The present study aimed to evaluate the clinical outcome and cost-effectiveness of PDA occlusion by Amplatzer and coil device in comparisong with open surgery. In this cross-sectional study, a randomized sample of 201 patients aged 1 month to 16 years (105 patients with device closure and 96 patients with surgical closure) was selected. The ratio of total pulmonary blood flow to total systemic blood flow, the Qp/Qs ratio, was measured using a pulmonary artery catheter. The cost analysis included direct medical care costs associated with device implantation and open surgery, as well as professional fees. All costs were calculated in Iranian Rials and then converted to US dollars. There was no statistical difference in mean Qp/Qs ratio before the procedure between the device closure group and the open surgery group (2.1 ± 0.7 versus 1.7 ± 0.6, P = 0.090). The mean measured costs were overall higher in the device closure group than in open closure group (948.87 ± 548.76 US$ versus 743.70 ± 696.91 US$, P < 0.001). This difference remained significant after adjustment for age and gender (Standardized Beta = 0.160, P = 0.031). PDA closure with the Amplatzer ductal occluder (1053.05 ± 525.73 US$) or with Nit-Occlud coils (PFM) (912.73 ± 565.94 US$, P < 0.001) was more expensive than that via open surgery. However, the Cook detachable spring coils device closure (605.65 ± 194.62 US$, P = 0.650) had a non-significant cost difference with open surgery. No event was observed in the device closure group regarding in-hospital mortality or morbidity; however, in another group, 2 in-hospital deaths occurred, two patients experienced pneumonia and seizure, and one suffered electrolyte abnormalities including hyponatremia and hypocalcemia. Although open surgery seems to be less expensive than device closure technique, because of lower mortality and morbidity, the latter group is more preferable.

  4. Negative pressure wound therapy management of the “open abdomen” following trauma: a prospective study and systematic review

    PubMed Central

    2013-01-01

    Introduction The use of Negative Pressure Wound Therapy (NPWT) for temporary abdominal closure of open abdomen (OA) wounds is widely accepted. Published outcomes vary according to the specific nature and the aetiology that resulted in an OA. The aim of this study was to evaluate the effectiveness of a new NPWT system specifically used OA resulting from abdominal trauma. Methods A prospective study on trauma patients requiring temporary abdominal closure (TAC) with grade 1or 2 OA was carried out. All patients were treated with NPWT (RENASYS AB Smith & Nephew) to achieve TAC. The primary outcome measure was time taken to achieve fascial closure and secondary outcomes were complications and mortality. Results A total of 20 patients were included. Thirteen patients (65%) achieved fascial closure following a median treatment period of 3 days. Four patients (20%) died of causes unrelated to NPWT. Complications included fistula formation in one patient (5%) with spontaneous resolution during NPWT), bowel necrosis in a single patient (5%) and three cases of infection (15%). No fistulae were present at the end of NPWT. Conclusion This new NPWT kit is safe and effective and results in a high rate of fascial closure and low complication rates in the severely injured trauma patient. PMID:23305306

  5. Immunogenicity of therapeutic proteins. Part 2: impact of container closures.

    PubMed

    Sharma, Basant

    2007-01-01

    Immunogenicity as a potential consequence of therapeutic protein administration is increasingly being scrutinized in the biopharmaceuticals industry, particularly with the imminent introduction of biosimilar products. Immunogenicity is an important safety aspect requiring rigorous investigation to fully appreciate its impact. Factors involved in product handling, such as storage temperature, light exposure, and shaking, have been implicated in immunogenicity, while container closure systems are no less important. Intended to provide a stable environment for the dosage form, container closures may also interact with a product, affecting performance and potentially enhancing immunogenicity. Glass surfaces, air-liquid interfaces, and lubricants can mediate protein denaturation, while phthalates in plastics and latex rubber are sources of extractables and leachates that may contaminate a product, causing allergic reactions and increasing immunogenicity. The manufacture of therapeutic proteins therefore requires rigorous safety evaluations not just in the context of the product, but also product containment.

  6. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  7. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  8. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  9. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  10. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  11. 10 CFR 60.112 - Overall system performance objective for the geologic repository after permanent closure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... repository after permanent closure. 60.112 Section 60.112 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH-LEVEL RADIOACTIVE WASTES IN GEOLOGIC REPOSITORIES Technical Criteria Performance Objectives § 60.112 Overall system performance objective for the geologic repository after permanent closure...

  12. A simple model for closure temperature of a trace element in cooling bi-mineralic systems

    NASA Astrophysics Data System (ADS)

    Liang, Yan

    2015-09-01

    Closure temperature is defined as the lower temperature limit at which the element of interest effectively ceases diffusive exchange with its surrounding medium during cooling. Here we generalize the classic equation of Dodson (1973) for cooling mono-mineralic systems to cooling bi-mineralic aggregates by considering diffusive exchange of a trace element between the two minerals in a closed system. We present a simple analytical model that includes key parameters affecting the closure temperature of a trace element in cooling bi-mineralic systems: cooling rate, temperature-dependent diffusion coefficients for the trace element in the two minerals, temperature-dependent partition coefficient of the trace element between the two minerals, effective grain sizes of the two minerals, and volume proportions of the minerals in the system. We show that closure temperatures of a trace element in cooling bi-mineralic systems are bounded by the closure temperatures of the trace element in the two mono-mineralic systems and that our generalized model reduces to Dodson's equation when one of the mineral serves as "an effective infinite" reservoir to the other mineral. Application to closure temperatures of REE in orthopyroxene and clinopyroxene bi-mineralic systems highlights the importance of REE diffusion and partitioning in the pyroxenes as well as clinopyroxene modal abundance and grain size in the systems. Closure temperatures for REE in two-pyroxene bearing equigranular rocks are controlled primarily by diffusion in orthopyroxene unless the modal abundance of clinopyroxene is very small. This has important bearings on the interpretation of temperatures derived from the REE-in-two-pyroxene thermometer.

  13. Space ecosynthesis: An approach to the design of closed ecosystems for use in space

    NASA Technical Reports Server (NTRS)

    Macelroy, R. D.; Averner, M. M.

    1978-01-01

    The use of closed ecological systems for the regeneration of wastes, air, and water is discussed. It is concluded that such systems, if they are to be used for the support of humans in space, will require extensive mechanical and physico-chemical support. The reason for this is that the buffering capacity available in small systems is inadequate, and that natural biological and physical regulatory mechanisms rapidly become inoperative. It is proposed that mathematical models of the dynamics of a closed ecological system may provide the best means of studying the initial problems of ecosystem closure. A conceptual and mathematical model of a closed ecosystem is described which treats the biological components as a farm, calculates the rates of flow of elements through the system by mass-balance techniques and control theory postulates, and can evaluate the requirements for mechanical buffering activities. It is suggested that study of the closure of ecosystems can significantly aid in the establishment of general principles of ecological systems.

  14. Life Support System Technologies for NASA Exploration Missions

    NASA Technical Reports Server (NTRS)

    Ewert, Michael K.

    2007-01-01

    The Lunar Mars Life Support Test series successfully demonstrated integration and operation of advanced technologies for closed-loop life support systems, including physicochemical and biological subsystems. Increased closure was obtained when targeted technologies, such as brine dewatering subsystems, were added to further process life support system byproducts to recover resources. Physicochemical and biological systems can be integrated satisfactorily to achieve desired levels of closure. Imbalances between system components, such as differences in metabolic quotients between human crews and plants, must be addressed. Each subsystem or component that is added to increase closure will likely have added costs, ranging from initial launch mass, power, thermal, crew time, byproducts, etc., that must be factored into break even analysis. Achieving life support system closure while maintaining control of total mass and system complexity will be a challenge.

  15. Cyanoacrylate closure of incompetent great, small and accessory saphenous veins without the use of post-procedure compression: Initial outcomes of a post-market evaluation of the VenaSeal System (the WAVES Study).

    PubMed

    Gibson, Kathleen; Ferris, Brian

    2017-04-01

    Purpose Cyanoacrylate closure of the great saphenous vein with the VenaSeal™ Closure System is a relatively new modality. Studies have been limited to moderate-sized great saphenous veins and some have mandated postoperative compression stockings. We report the results of a prospective study of cyanoacrylate closure for the treatment of great saphenous vein, small saphenous veins, and/or accessory saphenous veins up to 20 mm in diameter. Methods Fifty subjects with symptomatic great saphenous vein, small saphenous veins, and/or accessory saphenous veins incompetence were each treated at a single session. Compression stockings were not used post-procedure. Subjects returned to clinic at week 1 and again at one month. Post-procedure evaluations were performed at seven days and one month and included numerical pain rating score, revised venous clinical severity score, the Aberdeen Varicose Vein Questionnaire score, and time to return to work and normal activities. Duplex ultrasound was performed at each visit. Findings Procedural pain was mild (numerical pain rating scale 2.2 ± 1.8). All treated veins (48 great saphenous vein, 14 accessory saphenous veins, and 8 small saphenous veins) had complete closure by duplex ultrasound at seven days and one month. Mean time to return to work and normal activities was 0.2 ± 1.1 and 2.4 ± 4.1 days, respectively. The revised venous clinical severity score was improved to 1.8 ± 1.4 ( p < .001) and Aberdeen Varicose Vein Questionnaire score to 8.9 ± 6.6 ( p < .001) at one month. Phlebitis in the treatment area or side branches occurred in 10 subjects (20%) and completely resolved in all but one subject (2%) by one month; 98% of subjects were "completely" or "somewhat" satisfied, and 2% "unsatisfied" with the procedure at one month, despite the protocol disallowance of concomitant side branch treatment. Conclusions Cyanoacrylate closure is safe and effective for the treatment of one or more incompetent saphenous or accessory saphenous veins. Closure rates were high even in the absence of the use of compression stockings or side branch treatment. Time back to work or normal activities was short and improvements in venous severity scores and QOL were significant, comparing favorably with alternative treatment methods.

  16. Performance of four turbulence closure models implemented using a generic length scale method

    USGS Publications Warehouse

    Warner, J.C.; Sherwood, C.R.; Arango, H.G.; Signell, R.P.

    2005-01-01

    A two-equation turbulence model (one equation for turbulence kinetic energy and a second for a generic turbulence length-scale quantity) proposed by Umlauf and Burchard [J. Marine Research 61 (2003) 235] is implemented in a three-dimensional oceanographic model (Regional Oceanographic Modeling System; ROMS v2.0). These two equations, along with several stability functions, can represent many popular turbulence closures, including the k-kl (Mellor-Yamada Level 2.5), k-??, and k-?? schemes. The implementation adds flexibility to the model by providing an unprecedented range of turbulence closure selections in a single 3D oceanographic model and allows comparison and evaluation of turbulence models in an otherwise identical numerical environment. This also allows evaluation of the effect of turbulence models on other processes such as suspended-sediment distribution or ecological processes. Performance of the turbulence models and sediment-transport schemes is investigated with three test cases for (1) steady barotropic flow in a rectangular channel, (2) wind-induced surface mixed-layer deepening in a stratified fluid, and (3) oscillatory stratified pressure-gradient driven flow (estuarine circulation) in a rectangular channel. Results from k-??, k-??, and gen (a new closure proposed by Umlauf and Burchard [J. Marine Research 61 (2003) 235]) are very similar for these cases, but the k-kl closure results depend on a wall-proximity function that must be chosen to suit the flow. Greater variations appear in simulations of suspended-sediment concentrations than in salinity simulations because the transport of suspended-sediment amplifies minor variations in the methods. The amplification is caused by the added physics of a vertical settling rate, bottom stress dependent resuspension, and diffusive transport of sediment in regions of well mixed salt and temperature. Despite the amplified sensitivity of sediment to turbulence models in the estuary test case, the four closures investigated here all generated estuarine turbidity maxima that were similar in their shape, location, and concentrations. 

  17. Effectiveness and costs of overland skid trail BMPs

    Treesearch

    Clay Sawyers; W. Michael Aust; M. Chad Bolding; William A. Lakel III

    2012-01-01

    Forestry Best Management Practices (BMPs) are designed to protect water quality; however, little data exists comparing the efficacy and costs of different BMP options for skid trail closure. Study objectives were to evaluate erosion control effectiveness and implementation costs of five overland skid trail closure techniques. Closure techniques were: waterbar only (...

  18. Material balance and diet in bioregenerative life support systems: connection with coefficient of closure.

    PubMed

    Manukovsky, N S; Kovalev, V S; Somova, L A; Gurevich, Yu L; Sadovsky, M G

    2005-01-01

    Bioregenerative life support systems (BLSS) with different coefficients of closure are considered. The 66.2% coefficient of closure achieved in "BIOS-3" facility experiments has been taken as a base value. The increase in coefficient of closure up to 72.6-93.0% is planned due to use of soil-like substrate (SLS) and concentrating of urine. Food values were estimated both in a base variant ("BIOS-3"), and with increases in the coefficient of closure. It is shown that food requirements will be more fully satisfied by internal crop production with an increase in the coefficient of closure of the BLSS. Changes of massflow rates on an 'input-output' and inside BLSS are considered. Equations of synthesis and degradation of organic substances in BLSS were examined using a stoichiometric model. The paper shows that at incomplete closure of BLSS containing SLS there is a problem of nitrogen balancing. To compensate for the removal of nitrogen from the system in urine and feces, it is necessary to introduce food and a nitrogen-containing additive. c2005 COSPAR. Published by Elsevier Ltd. All rights reserved.

  19. Self-testing security sensor for monitoring closure of vault doors and the like

    DOEpatents

    Cawthorne, Duane C.

    1997-05-27

    A self-testing device is provided for a monitoring system for monitoring whether a closure member such as a door or window is closed. The monitoring system includes a switch unit mounted on the frame of the closure member being monitored and including magnetically biased switches connected in one or more electrical monitoring circuits, and a door magnet unit mounted on the closure member being monitored. The door magnet includes one or more permanent magnets that produce a magnetic field which, when the closure member is closed, cause said switches to assume a first state. When the closure member is opened, the switches switch to a second, alarm state. The self-testing device is electrically controllable from a remote location and produces a canceling or diverting magnetic field which simulates the effect of movement of the closure member from the closed position thereof without any actual movement of the member.

  20. Self-testing security sensor for monitoring closure of vault doors and the like

    DOEpatents

    Cawthorne, D.C.

    1997-05-27

    A self-testing device is provided for a monitoring system for monitoring whether a closure member such as a door or window is closed. The monitoring system includes a switch unit mounted on the frame of the closure member being monitored and including magnetically biased switches connected in one or more electrical monitoring circuits, and a door magnet unit mounted on the closure member being monitored. The door magnet includes one or more permanent magnets that produce a magnetic field which, when the closure member is closed, cause said switches to assume a first state. When the closure member is opened, the switches switch to a second, alarm state. The self-testing device is electrically controllable from a remote location and produces a canceling or diverting magnetic field which simulates the effect of movement of the closure member from the closed position thereof without any actual movement of the member. 5 figs.

  1. Evaluation of the Momentum Closure Schemes in MPAS-Ocean

    NASA Astrophysics Data System (ADS)

    Zhao, Shimei; Liu, Yudi; Liu, Wei

    2018-04-01

    In order to compare and evaluate the performances of the Laplacian viscosity closure, the biharmonic viscosity closure, and the Leith closure momentum schemes in the MPAS-Ocean model, a variety of physical quantities, such as the relative reference potential energy (RPE) change, the RPE time change rate (RPETCR), the grid Reynolds number, the root mean square (RMS) of kinetic energy, and the spectra of kinetic energy and enstrophy, are calculated on the basis of results of a 3D baroclinic periodic channel. Results indicate that: 1) The RPETCR demonstrates a saturation phenomenon in baroclinic eddy tests. The critical grid Reynolds number corresponding to RPETCR saturation differs between the three closures: the largest value is in the biharmonic viscosity closure, followed by that in the Laplacian viscosity closure, and that in the Leith closure is the smallest. 2) All three closures can effectively suppress spurious dianeutral mixing by reducing the grid Reynolds number under sub-saturation conditions of the RPETCR, but they can also damage certain physical processes. Generally, the damage to the rotation process is greater than that to the advection process. 3) The dissipation in the biharmonic viscosity closure is strongly dependent on scales. Most dissipation concentrates on small scales, and the energy of small-scale eddies is often transferred to large-scale kinetic energy. The viscous dissipation in the Laplacian viscosity closure is the strongest on various scales, followed by that in the Leith closure. Note that part of the small-scale kinetic energy is also transferred to large-scale kinetic energy in the Leith closure. 4) The characteristic length scale L and the dimensionless parameter D in the Leith closure are inherently coupled. The RPETCR is inversely proportional to the product of D and L. When the product of D and L is constant, both the simulated RPETCR and the inhibition of spurious dianeutral mixing are the same in all tests using the Leith closure. The dissipative scale in the Leith closure depends on the parameter L, and the dissipative intensity depends on the parameter D. 5) Although optimal results may not be achieved by using the optimal parameters obtained from the 2D barotropic model in the 3D baroclinic simulation, the total energies are dissipative in all three closures. Dissipation is the strongest in the biharmonic viscosity closure, followed by that in the Leith closure, and that in the Laplacian viscosity closure is the weakest. Mesoscale eddies develop the fastest in the biharmonic viscosity closure after the baroclinic adjustment process finishes, and the kinetic energy reaches its maximum, which is attributed to the smallest dissipation of enstrophy in the biharmonic viscosity closure. Mesoscale eddies develop the slowest, and the kinetic energy peak value is the smallest in the Laplacian viscosity closure. Results in the Leith closure are between that in the biharmonic viscosity closure and the Laplacian viscosity closure.

  2. Severe Accident Sequence Analysis Program: Anticipated transient without scram simulations for Browns Ferry Nuclear Plant Unit 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dallman, R J; Gottula, R C; Holcomb, E E

    1987-05-01

    An analysis of five anticipated transients without scram (ATWS) was conducted at the Idaho National Engineering Laboratory (INEL). The five detailed deterministic simulations of postulated ATWS sequences were initiated from a main steamline isolation valve (MSIV) closure. The subject of the analysis was the Browns Ferry Nuclear Plant Unit 1, a boiling water reactor (BWR) of the BWR/4 product line with a Mark I containment. The simulations yielded insights to the possible consequences resulting from a MSIV closure ATWS. An evaluation of the effects of plant safety systems and operator actions on accident progression and mitigation is presented.

  3. Outcomes of mechanical stapling for postlaryngectomy open pharyngotomy closure.

    PubMed

    Paddle, Paul; Husain, Inna; McHugh, Lauren; Franco, Ramon

    2017-03-01

    A total laryngectomy (TL) is performed as a primary or salvage therapy for laryngeal carcinoma. Pharyngotomy closure after TL is typically performed using manual sutures. Automatic stapling devices are routinely used in thoracoabdominal surgery, but have not been widely accepted for use in pharyngotomy closure. Previously described closed stapling techniques of pharyngeal closure do not allow direct evaluation of surgical margins and are limited to endolaryngeal disease. We describe an open technique for pharyngotomy closure using a mechanical stapling device. Retrospective review. A review was conducted of 16 total laryngectomies performed from May 2008 to August 2015 utilizing an Ethicon Endopath ETS Compact-Flex 45 stapler. Sixteen patients (15 male, one female), mean age 69 years, received open TL (14 salvage, two primary) with endostapler pharyngeal closure and primary tracheoesophageal puncture (TEP). Surgical time averaged 218 minutes. Median time to swallowing was 4 days (range, 2-240 days) and mean hospital stay 6 days (range, 3-10 days). Fistula incidence was 31% (5/16) overall and 36% (5/14) in the postradiation patients. Mechanical stapling is a simple method for postlaryngectomy open pharyngotomy closure. This technique allows evaluation of margins, easy primary TEP, and the opportunity for early swallowing and shorter hospital stays. In addition, it can be performed for closure of salvage laryngectomies with rates of fistula formation similar to that found in the literature using suture closure techniques. Future studies are necessary to compare oncological results and surgical complications between the open and closed stapling techniques and to traditional suture closure. 4 Laryngoscope, 127:605-610, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  4. 300 Area waste acid treatment system closure plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LUKE, S.N.

    1999-05-17

    The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (document number DOERL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion includes closure plan documentation submitted for individual, treatment, storage, and/or disposal units undergoing closure, such as the 300 Area Waste Acid Treatment System. Documentation contained in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units (e.g., the glossary provided in the General Information Portion). Whenever appropriate, 300 Area Waste Acid Treatment System documentation makes cross-reference to themore » General Information Portion, rather than duplicating text. This 300 Area Waste Acid Treatment System Closure Plan (Revision 2) includes a Hanford Facility Dangerous Waste Permit Application, Part A, Form 3. Information provided in this closure plan is current as of April 1999.« less

  5. Solidifying Segregation or Promoting Diversity? School Closure and Rezoning in an Urban District

    ERIC Educational Resources Information Center

    Siegel-Hawley, Genevieve; Bridges, Kimberly; Shields, Thomas J.

    2017-01-01

    Purpose: Layered with myriad considerations, school closure and rezoning processes in urban school systems are politically fraught with the potential for damaging consequences. This article explores the politics and impacts of a closure and rezoning process in Richmond, Virginia, through the lens of themes applicable to urban school systems and…

  6. Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.

    PubMed

    Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz

    2015-06-01

    The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.

  7. Post-Closure Strategy for Use-Restricted Sites on the Nevada National Security Site, Nevada Test and Training Range, and Tonopah Test Range, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silvas, A. J.

    The purpose of this Post-Closure Strategy is to provide a consistent methodology for continual evaluation of post-closure requirements for use-restricted areas on the Nevada National Security Site (NNSS), Nevada Test and Training Range (NTTR), and Tonopah Test Range (TTR) to consolidate, modify, or streamline the program. In addition, this document stipulates the creation of a single consolidated Post-Closure Plan that will detail the current post-closure requirements for all active use restrictions (URs) and outlines its implementation and subsequent revision. This strategy will ensure effective management and control of the post-closure sites. There are currently over 200 URs located on themore » NNSS, NTTR, and TTR. Post-closure requirements were initially established in the Closure Report for each site. In some cases, changes to the post-closure requirements have been implemented through addenda, errata sheets, records of technical change, or letters. Post-closure requirements have been collected from these multiple sources and consolidated into several formats, such as summaries and databases. This structure increases the possibility of inconsistencies and uncertainty. As more URs are established and the post-closure program is expanded, the need for a comprehensive approach for managing the program will increase. Not only should the current requirements be obtainable from a single source that supersedes all previous requirements, but the strategy for modifying the requirements should be standardized. This will enable more effective management of the program into the future. This strategy document and the subsequent comprehensive plan are to be implemented under the assumption that the NNSS and outlying sites will be under the purview of the U.S. Department of Energy, National Nuclear Security Administration for the foreseeable future. This strategy was also developed assuming that regulatory control of the sites remains static. The comprehensive plan is not intended to be a permanent long-term stewardship plan. However, it is intended to clarify requirements and identify components to effectively manage the sites until regulatory requirements are met or management of the site changes. The Environmental Management Program is required to manage these sites until the NNSS Environmental Restoration program is completed, currently planned for 2030. Prior to completion of the Environmental Restoration program, additional planning will be conducted to ensure that long-term stewardship of the sites is maintained. A comprehensive post-closure plan can be transitioned effectively into any future site-wide long-term stewardship program that may be developed. Therefore, the post-closure plan will include current aspects of the post-closure program that are also important aspects of long-term stewardship, including the following: • Management of physical and engineering controls such as fences, signs, and soil covers • Management of institutional and administrative controls such as use restrictions and real estate systems • Management of monitoring and maintenance programs • Management of information related to the sites such as geographic information system data and related documentation The strategy will also allow for periodic review and modification of any aspect of the program to ensure continued effectiveness.« less

  8. Evaluation of innovative devices to control traffic entering from low-volume access points within a land closure.

    DOT National Transportation Integrated Search

    2014-04-01

    This report describes the methodology and results of analyses performed to identify and evaluate : alternative methods to control traffic entering a lane closure on a two-lane, two-way road from low-volume : access points. Researchers documented the ...

  9. Evaluation of Unintended Social and Economic Consequences of an Unplanned School Closure in Rural Illinois

    ERIC Educational Resources Information Center

    Tsai, Victoria; Khan, Nomana M.; Shi, Jianrong; Rainey, Jeanette; Gao, Hongjiang; Zheteyeva, Yenlik

    2017-01-01

    Background: School closure is one of the primary measures considered during severe influenza pandemics and other emergencies. However, prolonged school closures may cause unintended adverse consequences to schools, students, and their families. A better understanding of these consequences will inform prepandemic planning, and help public health…

  10. Speckle-Tracking Echocardiography in Dogs With Patent Ductus Arteriosus: Effect of Percutaneous Closure on Cardiac Mechanics.

    PubMed

    Spalla, I; Locatelli, C; Zanaboni, A M; Brambilla, P; Bussadori, C

    2016-05-01

    Patent ductus arteriosus (PDA) is 1 of the most common congenital heart defects in dogs and percutaneous closure is effective in achieving ductal closure; PDA closure is associated with abrupt hemodynamic changes. A marked decrease in standard parameters of systolic function as assessed by M- or B-mode echocardiography after PDA closure was identified in previous studies. Speckle tracking echocardiography can provide further insight into the effect of PDA closure on cardiac mechanics in dogs affected by PDA. Twenty-five client-owned dogs with PDA. Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed before and 24 hours after PDA closure, including standard (end-diastolic volumes indexed to body surface area in B- and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B- and M-mode [ESVIB /M ], allometric scaling in diastole [AlloD] and systole [AlloS], pulmonary flow to systemic flow [Qs/Qp], ejection fraction [EF], and fractional shortening [FS]), and advanced speckle-tracking echocardiography (STE): global longitudinal, radial, circumferential and transverse strain (S), and strain rate (SR). Patent ductus arteriosus closure was associated with statistically significant decreases in EDVIM /B and ESVIM /B , AlloD and AlloS, SI, EF, and FS. A statistically significant decrease in the absolute values of radial, transverse, and circumferential S and SR was observed, whereas longitudinal S and SR did not change significantly. Patent ductus arteriosus closure by percutaneous approach is associated with marked decreases of conventional echocardiographic parameters as a result of the changes in loading conditions, but no evidence of systolic dysfunction was identified by means of STE, as none of the S and SR values were below reference ranges. In the short term, contractility is enhanced in the long axis (long S/SR values were not statistically different before and after closure) and decreases to normal values in short axis (circumferential, radial, and transversal S/SR decreased to normal reference range). Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  11. Natural orifice transluminal endoscopic surgery gastrotomy closure with an over-the-endoscope clip: a randomized, controlled porcine study (with videos).

    PubMed

    von Renteln, Daniel; Schmidt, Arthur; Vassiliou, Melina C; Gieselmann, Maria; Caca, Karel

    2009-10-01

    Secure endoscopic closure of transgastric natural orifice transluminal endoscopic surgery (NOTES) access is of paramount importance. The over-the-scope clip (OTSC) system has previously been shown to be effective for NOTES gastrotomy closure. To compare OTSC gastrotomy closure with surgical closure. Randomized, controlled animal study. Animal facility laboratory. Thirty-six female domestic pigs. Gastrotomies were created by using a needle-knife and an 18-mm balloon. The animals were subsequently randomized to either open surgical repair with interrupted sutures or endoscopic repair with 12-mm OTSCs. In addition, pressurized leak tests were performed in ex vivo specimens of 18-mm scalpel incisions closed with suture (n = 14) and of intact stomachs (n = 10). The mean time for endoscopic closure was 9.8 minutes (range 3-22, SD 5.5). No complications occurred during either type of gastrotomy closure. At necropsy, examination of all OTSC and surgical closures demonstrated complete sealing of gastrotomy sites without evidence of injury to adjacent organs. Pressurized leak tests showed a mean burst pressure of 83 mm Hg (range 30-140, SD 27) for OTSC closures and 67 mm Hg (range 30-130, SD 27.7) for surgical sutures. Ex vivo hand-sewn sutures of 18-mm gastrotomies (n = 14) exhibited a mean burst pressure of 65 mm Hg (range 20-140, SD 31) and intact ex vivo stomachs (n = 10) had a mean burst pressure of 126 mm Hg (range 90-170, SD 28). The burst pressure of ex vivo intact stomachs was significantly higher compared with OTSC closures (P < .01), in vivo surgical closures (P < .01), and ex vivo hand-sewn closures (P < .01). There was a trend toward higher burst pressures in the OTSC closures compared with surgical closures (P = .063) and ex vivo hand-sewn closures (P = .094). In vivo surgical closures demonstrated similar burst pressures compared with ex vivo hand-sewn closures (P = .848). Nonsurvival setting. Endoscopic closure by using the OTSC system is comparable to surgical closure in a nonsurvival porcine model. This technique is easy to perform and is suitable for NOTES gastrotomy closure.

  12. [The prevalence of blindness caused by primary angle closure glaucoma in middle-aged Chinese population: a systematic review and meta-analysis].

    PubMed

    Liu, M L; Wang, Y X

    2017-05-11

    Objective: To evaluate the rate of blindness caused by primary angle closure glaucoma (PACG) in Chinese population of more than 40 years old, and to explore the effectiveness of a prevention and treatment system on PACG. Methods: We searched the databases of Pubmed, ScienceDirect, Springer Link, CNKI and Wanfang Data and collected all the original studies of the prevalence and blindness of angle closure glaucoma in China. The population was limited to over 40 years old. The research site was limited to the community-based, while the published time was not limited. Two researchers completed the literature search, data extraction and methodological quality assessment independently, with same criteria. Meta analysis was performed using R software. Results: Five papers were included in this study finally. A total of 26 437 cases of natural population over the age of 40 were observed, and 306 cases of angle closure glaucoma were found, of which 113 cases had binocular or monocular blindness caused by PACG. The random effect model meta-analysis results showed that the overall blindness rate was 38.3% [95% CI (28.1%, 49.6%)]. In Beijing, where the prevention and treatment system was well established, the blindness rate was far lower than that in the areas where the system was poorly established. Compared with the past, the blindness rate caused by PACG in Beijing decreased sharply. Conclusions: The rate of blindness caused by PACG is still high in the mainland of China. The prevention and treatment system is effective and worth promoting. (Chin J Ophthalmol, 2017, 53: 373 - 377) .

  13. A biomechanical comparison of three sternotomy closure techniques.

    PubMed

    Cohen, David J; Griffin, Lanny V

    2002-02-01

    A biomechanical study of three sternotomy closure techniques (figure-of-eight stainless-steel wires, Pectofix Dynamic Sternal Fixation [DSF] stainless-steel plates, and figure-of-eight stainless-steel cables) was conducted to compare strength and stiffness variables in three clinically relevant loading modes (anterior-posterior shear, longitudinal shear, and lateral distraction). All tests were conducted on polyurethane foam sternal models that simulate the properties of cancellous bone. Each model was divided longitudinally and reconstructed using one of the sternotomy closure repair techniques. Tests were performed using a materials testing system that applies a continuously increasing amount of force in one direction to the model until it catastrophically breaks. A total of six trials of each fixation type in each of three test groups were prepared and tested, for a total of 54 tests. Strength and stiffness variables as well as a post-yield analysis of failure were evaluated. Sternums repaired using the DSF plate system are a more rigid construct than sternums repaired using the stainless-steel wires or cables in the distraction and transverse shear modes and they are not significantly different from sternums repaired with wires or cables in the longitudinal shear mode. The DSF plate system offers a 25% improvement in resistance to failure (yield) compared to wires when a transverse shear force is applied to the model. The cable system had a higher resistance to failure than the wires in all modes although the differences were not statistically significant. Additionally, the DSF plate system provides substantial reduction of the implant's cutting into the sternal model under loading as evidenced by the post-yield displacement when compared with either cables or wires for the distraction and longitudinal shear modes. For the transverse shear mode, the cables or wires would completely fail at the load for which cutting begins for the DSF. Both the DSF plate system and the stainless-steel cable system offer important advantages over figure-of-eight wire for sternal closure.

  14. Magnetohydrodynamic motion of a two-fluid plasma

    DOE PAGES

    Burby, Joshua W.

    2017-07-21

    Here, the two-fluid Maxwell system couples frictionless electron and ion fluids via Maxwell’s equations. When the frequencies of light waves, Langmuir waves, and single-particle cyclotron motion are scaled to be asymptotically large, the two-fluid Maxwell system becomes a fast-slow dynamical system. This fast-slow system admits a formally-exact single-fluid closure that may be computed systematically with any desired order of accuracy through the use of a functional partial differential equation. In the leading order approximation, the closure reproduces magnetohydrodynamics (MHD). Higher order truncations of the closure give an infinite hierarchy of extended MHD models that allow for arbitrary mass ratio, asmore » well as perturbative deviations from charge neutrality. The closure is interpreted geometrically as an invariant slow manifold in the infinite-dimensional two-fluid phase space, on which two-fluid motions are free of high-frequency oscillations. This perspective shows that the full closure inherits a Hamiltonian structure from two-fluid theory. By employing infinite-dimensional Lie transforms, the Poisson bracket for the all-orders closure may be obtained in closed form. Thus, conservative truncations of the single-fluid closure may be obtained by simply truncating the single-fluid Hamiltonian. Moreover, the closed-form expression for the all-orders bracket gives explicit expressions for a number of the full closure’s conservation laws. Notably, the full closure, as well as any of its Hamiltonian truncations, admits a pair of independent circulation invariants.« less

  15. Magnetohydrodynamic motion of a two-fluid plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burby, Joshua W.

    Here, the two-fluid Maxwell system couples frictionless electron and ion fluids via Maxwell’s equations. When the frequencies of light waves, Langmuir waves, and single-particle cyclotron motion are scaled to be asymptotically large, the two-fluid Maxwell system becomes a fast-slow dynamical system. This fast-slow system admits a formally-exact single-fluid closure that may be computed systematically with any desired order of accuracy through the use of a functional partial differential equation. In the leading order approximation, the closure reproduces magnetohydrodynamics (MHD). Higher order truncations of the closure give an infinite hierarchy of extended MHD models that allow for arbitrary mass ratio, asmore » well as perturbative deviations from charge neutrality. The closure is interpreted geometrically as an invariant slow manifold in the infinite-dimensional two-fluid phase space, on which two-fluid motions are free of high-frequency oscillations. This perspective shows that the full closure inherits a Hamiltonian structure from two-fluid theory. By employing infinite-dimensional Lie transforms, the Poisson bracket for the all-orders closure may be obtained in closed form. Thus, conservative truncations of the single-fluid closure may be obtained by simply truncating the single-fluid Hamiltonian. Moreover, the closed-form expression for the all-orders bracket gives explicit expressions for a number of the full closure’s conservation laws. Notably, the full closure, as well as any of its Hamiltonian truncations, admits a pair of independent circulation invariants.« less

  16. 40 CFR 280.71 - Permanent closure and changes-in-service.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.71 Permanent closure and changes... sludges. All tanks taken out of service permanently must also be either removed from the ground or filled with an inert solid material. (c) Continued use of an UST system to store a non-regulated substance is...

  17. 40 CFR 280.71 - Permanent closure and changes-in-service.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.71 Permanent closure and changes... sludges. All tanks taken out of service permanently must also be either removed from the ground or filled with an inert solid material. (c) Continued use of an UST system to store a non-regulated substance is...

  18. 40 CFR 280.71 - Permanent closure and changes-in-service.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.71 Permanent closure and changes... sludges. All tanks taken out of service permanently must also be either removed from the ground or filled with an inert solid material. (c) Continued use of an UST system to store a non-regulated substance is...

  19. 40 CFR 280.71 - Permanent closure and changes-in-service.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.71 Permanent closure and changes... sludges. All tanks taken out of service permanently must also be either removed from the ground or filled with an inert solid material. (c) Continued use of an UST system to store a non-regulated substance is...

  20. Fenestrated Transcatheter ASD Closure in Adults with Diastolic Dysfunction and/or Pulmonary Hypertension: Case Series and Review of the Literature.

    PubMed

    Abdelkarim, Ayman; Levi, Daniel S; Tran, Bao; Ghobrial, Joanna; Aboulhosn, Jamil

    2016-12-01

    This study aims to evaluate the safety and efficacy of transcatheter fenestrated ASD closure and to summarize the literature regarding the published techniques and outcomes of transcatheter partial ASD closure. Patients with left ventricular diastolic dysfunction (LVDD) or right ventricular (RV) dysfunction and/or pulmonary hypertension (PHT) may suffer untoward consequences of complete closure of an ostium secundum atrial septal defect (ASD). Therefore, for patients that fall under these categories we suggest partial occlusion of the defect, which may be better tolerated than complete defect closure. After obtaining IRB approval, a search for patients that have undergone percutaneous ASD closure was performed in the Ahmanson/UCLA Adult Congenital Heart Disease Center database to identify which patients received a fenestrated ASD closure device. Eight consecutive patients ranging between 22 and 83 years of age (mean 48 years) with PHT and/or LVDD or RV dysfunction who underwent fenestrated transcatheter ASD closure at UCLA were identified. None of the subjects experienced complications related to the procedure. Postprocedure clinical evaluation showed improvement in symptoms and exercise capacity. Available follow-up transthoracic echocardiography data (mean 4 months, range 0-20 months) demonstrated patent fenestrations in four of eight patients. None of the patients had thromboembolic or infectious complications and there were no device migrations, erosions or embolizations. Partial ASD occlusion in patients with diastolic dysfunction or RV dysfunction and/or PHT is safe and may be better tolerated than complete ASD closure in selected patients. © 2016 Wiley Periodicals, Inc.

  1. Evaluation of the effectiveness of octreotide in the conservative treatment of postoperative enterocutaneous fistulas.

    PubMed

    Alivizatos, Vassilos; Felekis, Dimitrios; Zorbalas, Athanasios

    2002-01-01

    The aim of this study was to evaluate the effectiveness of Octreotide as an adjunct treatment to total parenteral nutrition in the spontaneous closure of postoperative enterocutaneous fistulas. Medical records of 39 patients with postoperative enterocutaneous fistulas treated in our Department between January 1988 and August 2000 were reviewed. Sixteen patients had duodenal fistulas and 23 had jejunal or ileal fistulas. According to the daily output, there were 20 low fistula output and 19 high fistula output. Conservative treatment consisted of nutritional support with total parenteral nutrition in all the patients. Administration of Octreotide (100 micrograms every 8 hours, subcutaneously) was done in 21 consecutive patients until spontaneous closure of the fistulas or their subsequent surgical closure. The occurrence of fistulas closure was compared using the Fisher's exact test. A mean reduction of 50% of fistula output was noted in all the patients who received Octreotide, within 24 hours of its administration. Spontaneous closure was achieved in 13 patients of the Octreotide group (mean closure time: 15.3 days, range: 6-35) and in 12 patients treated only with total parenteral nutrition (mean closure time: 13.9 days, range: 7-25); this difference was not significant (P = 0.5). Also, the fistula closure rate was not influenced by the anatomic site, the high or low output, and the age of the patient. The results of this study suggest that, as an adjunct treatment to total parenteral nutrition, Octreotide reduces rapidly the fistula output without significant influence in the spontaneous closure rate.

  2. Reliability of excess-flow check-valves in turbine lubrication systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dundas, R.E.

    1996-12-31

    Reliability studies on excess-flow check valves installed in a gas turbine lubrication system for prevention of spray fires subsequent to fracture or separation of lube lines were conducted. Fault-tree analyses are presented for the case of failure of a valve to close when called upon by separation of a downstream line, as well as for the case of accidental closure during normal operation, leading to interruption of lubricating oil flow to a bearing. The probabilities of either of these occurrences are evaluated. The results of a statistical analysis of accidental closure of excess-flow check valves in commercial airplanes in themore » period 1986--91 are also given, as well as a summary of reliability studies on the use of these valves in residential gas installations, conducted under the sponsorship of the Gas Research Institute.« less

  3. Goose-neck snare-assisted transcatheter ASD closure: A safety procedure for large and complex ASDs.

    PubMed

    Butera, Gianfranco; Lovin, Nicusor; Basile, Domenica Paola; Carminati, Mario

    2016-04-01

    To report on a new technique that increases the safety of percutaneous atrial septal defect (ASD) closure using a goose-neck snare system. ASD transcatheter closure is a widespread procedure. However, in some cases, ASDs may be large and with soft rims. In these situation, a potential risk exists for device malposition or embolization. When transesophageal echocardiography (TEE) evaluation and balloon sizing showed large defects with floppy rims the chosen Amplatzer device was implanted in a standard way. In large defects with floppy rims, before release a 5-mm goose-neck snare with its 4 Fr catheter was placed across the delivery cable and fixed to catch the screwing mechanism of implanted Amplatzer device. The delivery cable was unscrewed and the device reached its final position without any tension. If the position was considered satisfactory the device was released from the goose-neck snare. Thirteen patients had a snare-assisted ASD transcatheter closure. Median device size was 24 mm (range 14-38 mm). Retrieval or repositioning of the device using the goose-neck snare was performed in four cases: in three patients, because of device malposition after delivery cable release and in one patient, because of unsuitability of closure of a second significant defect. Furthermore, in two subjects with multiple ASDs, a second fenestration looked quite significant with the device still attached to the delivery cable while it appeared smaller after release. Snare-assisted Amplatzer ASD device placement is a new method for ASD percutaneous closure and adds safety to the procedure. © 2016 Wiley Periodicals, Inc.

  4. Strain-energy release rate analysis of a laminate with a postbuckled delamination

    NASA Technical Reports Server (NTRS)

    Whitcomb, John D.; Shivakumar, K. N.

    1987-01-01

    The objectives are to present the derivation of the new virtual crack closure technique, evaluate the accuracy of the technique, and finally to present the results of a limited parametric study of laminates with a postbuckled delamination. Although the new virtual crack closure technique is general, only homogeneous, isotropic laminates were analyzed. This was to eliminate the variation of flexural stiffness with orientation, which occurs even for quasi-isotropic laminates. This made it easier to identify the effect of geometrical parameters on G. The new virtual crack closure technique is derived. Then the specimen configurations are described. Next, the stress analyses is discussed. Finally, the virtual crack closure technique is evaluated and then used to calculate the distribution of G along the delamination front of several laminates with a postbuckled delamination.

  5. The open abdomen and temporary abdominal closure systems--historical evolution and systematic review.

    PubMed

    Quyn, A J; Johnston, C; Hall, D; Chambers, A; Arapova, N; Ogston, S; Amin, A I

    2012-08-01

    Several techniques for temporary abdominal closure have been developed. We systematically review the literature on temporary abdominal closure to ascertain whether the method can be tailored to the indication. Medline, Embase, the Cochrane Central Register of Controlled Trials and relevant meeting abstracts until December 2009 were searched using the following headings: open abdomen, laparostomy, VAC (vacuum assisted closure), TNP (topical negative pressure), fascial closure, temporary abdominal closure, fascial dehiscence and deep wound dehiscence. The data were analysed by closure technique and aetiology. The primary end-points included delayed fascial closure and in-hospital mortality. The secondary end-points were intra-abdominal complications. The search identified 106 papers for inclusion. The techniques described were VAC (38 series), mesh/sheet (30 series), packing (15 series), Wittmann patch (eight series), Bogotá bag (six series), dynamic retention sutures (three series), zipper (15 series), skin only and locking device (one series each). The highest facial closure rates were seen with the Wittmann patch (78%), dynamic retention sutures (71%) and VAC (61%). Temporary abdominal closure has evolved from simple packing to VAC based systems. In the absence of sepsis Wittmann patch and VAC offered the best outcome. In its presence VAC had the highest delayed primary closure and the lowest mortality rates. However, due to data heterogeneity only limited conclusions can be drawn from this analysis. © 2012 The Authors. Colorectal Disease © 2012 The Association of Coloproctology of Great Britain and Ireland.

  6. Constraint Embedding Technique for Multibody System Dynamics

    NASA Technical Reports Server (NTRS)

    Woo, Simon S.; Cheng, Michael K.

    2011-01-01

    Multibody dynamics play a critical role in simulation testbeds for space missions. There has been a considerable interest in the development of efficient computational algorithms for solving the dynamics of multibody systems. Mass matrix factorization and inversion techniques and the O(N) class of forward dynamics algorithms developed using a spatial operator algebra stand out as important breakthrough on this front. Techniques such as these provide the efficient algorithms and methods for the application and implementation of such multibody dynamics models. However, these methods are limited only to tree-topology multibody systems. Closed-chain topology systems require different techniques that are not as efficient or as broad as those for tree-topology systems. The closed-chain forward dynamics approach consists of treating the closed-chain topology as a tree-topology system subject to additional closure constraints. The resulting forward dynamics solution consists of: (a) ignoring the closure constraints and using the O(N) algorithm to solve for the free unconstrained accelerations for the system; (b) using the tree-topology solution to compute a correction force to enforce the closure constraints; and (c) correcting the unconstrained accelerations with correction accelerations resulting from the correction forces. This constraint-embedding technique shows how to use direct embedding to eliminate local closure-loops in the system and effectively convert the system back to a tree-topology system. At this point, standard tree-topology techniques can be brought to bear on the problem. The approach uses a spatial operator algebra approach to formulating the equations of motion. The operators are block-partitioned around the local body subgroups to convert them into aggregate bodies. Mass matrix operator factorization and inversion techniques are applied to the reformulated tree-topology system. Thus in essence, the new technique allows conversion of a system with closure-constraints into an equivalent tree-topology system, and thus allows one to take advantage of the host of techniques available to the latter class of systems. This technology is highly suitable for the class of multibody systems where the closure-constraints are local, i.e., where they are confined to small groupings of bodies within the system. Important examples of such local closure-constraints are constraints associated with four-bar linkages, geared motors, differential suspensions, etc. One can eliminate these closure-constraints and convert the system into a tree-topology system by embedding the constraints directly into the system dynamics and effectively replacing the body groupings with virtual aggregate bodies. Once eliminated, one can apply the well-known results and algorithms for tree-topology systems to solve the dynamics of such closed-chain system.

  7. Mass extraction container closure integrity physical testing method development for parenteral container closure systems.

    PubMed

    Yoon, Seung-Yil; Sagi, Hemi; Goldhammer, Craig; Li, Lei

    2012-01-01

    Container closure integrity (CCI) is a critical factor to ensure that product sterility is maintained over its entire shelf life. Assuring the CCI during container closure (C/C) system qualification, routine manufacturing and stability is important. FDA guidance also encourages industry to develop a CCI physical testing method in lieu of sterility testing in a stability program. A mass extraction system has been developed to check CCI for a variety of container closure systems such as vials, syringes, and cartridges. Various types of defects (e.g., glass micropipette, laser drill, wire) were created and used to demonstrate a detection limit. Leakage, detected as mass flow in this study, changes as a function of defect length and diameter. Therefore, the morphology of defects has been examined in detail with fluid theories. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it has been verified that the method was robust, and capable of determining the acceptance limit using 3σ for syringes and 6σ for vials. Sterile products must maintain their sterility over their entire shelf life. Container closure systems such as those found in syringes and vials provide a seal between rubber and glass containers. This seal must be ensured to maintain product sterility. A mass extraction system has been developed to check container closure integrity for a variety of container closure systems such as vials, syringes, and cartridges. In order to demonstrate the method's capability, various types of defects (e.g., glass micropipette, laser drill, wire) were created in syringes and vials and were tested. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it was verified that the method showed consistent results, and was able to determine the acceptance limit using 3σ for syringes and 6σ for vials.

  8. Skin closure using staples and nylon sutures: a comparison of results.

    PubMed

    Stockley, I; Elson, R A

    1987-03-01

    A disposable skin stapler (Elite: Auto Suture UK Ltd) and Nylon vertical mattress sutures have been used for skin closure. The complications related to each method were evaluated in 129 wounds. There was a higher incidence of inflammation, discomfort on removal and spreading of the healing scar associated with staples. The only advantage of staples was speed of wound closure.

  9. Nickel-Titanium Wire as Suture Material: A New Technique for the Fixation of Skin.

    PubMed

    Li, Haidong; Song, Tao

    2018-01-29

    To introduce nickel-titanium wire as suture material for closure of incisions in cleft lip procedures. Closure of skin incisions using nickel-titanium wire as suture material, with postoperative follow-up wound evaluation. There was excellent patient satisfaction and good cosmetic outcome. Nickel-titanium wire is an excellent alternative for suture closure of cleft lip surgical incisions.

  10. Modified nondestructive colorimetric method to evaluate the variability of oxygen diffusion rate through wine bottle closures.

    PubMed

    Brotto, Laura; Battistutta, Franco; Tat, Lara; Comuzzo, Piergiorgio; Zironi, Roberto

    2010-03-24

    Some modifications to a previous nondestructive colorimetric method that permits evaluation of the oxygen diffusion rate through wine closures were proposed. The method is based on the reaction of indigo carmine solution with oxygen and the tristimulus measurement of the consequent color change. Simplified preparation and measurement procedures were set up, allowing the analysis of a large number of samples simultaneously. The method was applied to the evaluation of the variability within the lot of 20 different types of stoppers (synthetic, produced by molding, and natural cork). The closures were tested at a storage temperature of 26 degrees C. With regard to oxygen permeability, the natural cork stopper showed a low homogeneity within the lot, especially during the first month after bottling, whereas the synthetic closure showed a greater steadiness in the performance. The limits of the colorimetric method were also analyzed, and three possible causes of degradation of the indigo carmine solution were identified: oxygen, light, and heat.

  11. Pan-nitinol occluder and special delivery device for closure of patent ductus arteriosus: a canine-model feasibility study.

    PubMed

    Jiang, Hai-bin; Bai, Yuan; Zong, Gang-jun; Han, Lin; Li, Wei-ping; Lu, Yang; Qin, Yong-wen; Zhao, Xian-xian

    2013-01-01

    The aim of this study was to evaluate a new type of occluder for patent ductus arteriosus. Patent ductus arteriosus was established in a canine model by anastomosing a length of autologous jugular vein to the descending aorta and the left pulmonary artery in an end-to-side fashion. Transcatheter closure of each patent ductus arteriosus was performed on 10 dogs, which were then monitored for as long as 6 months with aortography, echocardiography, and histologic evaluation. Transcatheter closure with use of the novel pan-nitinol device was successful in all canine models. Postoperative echocardiography showed that the location and shape of the occluders were normal, without any residual shunting. Further histologic evaluation confirmed that the occluder surface was completely endothelialized 3 months after implantation. Transcatheter patent ductus arteriosus closure with the pan-nitinol occluder can be performed safely and successfully in a canine model and shows good biological compatibility and low mortality rates.

  12. Application of the cohesive zone model for the evaluation of stiffness losses in a rotor with a transverse breathing crack

    NASA Astrophysics Data System (ADS)

    Toni Liong, Rugerri; Proppe, Carsten

    2013-04-01

    The breathing mechanism of a transversely cracked rotor and its influence on a rotor system that appears due to shaft weight and inertia forces is studied. A method is proposed for the evaluation of the stiffness losses in the cross-section that contains the crack. This method is based on a cohesive zone model (CZM) instead of linear elastic fracture mechanics (LEFM). The CZM is developed for mode-I plane strain conditions and accounts explicitly for triaxiality of the stress state by using constitutive relations. The breathing crack is modelled by a parabolic shape. As long as the relative crack depth is small, a crack closure straight line model may be used, while the crack closure parabolic line should be used in the case of a deep crack. The CZM is also implemented in a one-dimensional continuum rotor model by means of finite element (FE) discretisation in order to predict and to analyse the dynamic behavior of a cracked rotor. The proposed method provides a useful tool for the analysis of rotor systems containing cracks.

  13. Permanent Closure of MFC Biodiesel Underground Storage Tank 99ANL00013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerry L. Nisson

    2012-10-01

    This closure package documents the site assessment and permanent closure of the Materials and Fuels Complex biodiesel underground storage tank 99ANL00013 in accordance with the regulatory requirements established in 40 CFR 280.71, “Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.”

  14. Effect Of N = 40 Shell Closure On Barrier Distributions In 18O+58,60Ni Reactions

    NASA Astrophysics Data System (ADS)

    Danu, L. S.; Nayak, B. K.; Saxena, A.; Biswas, D. C.; John, B. V.; Thomas, R. G.; Gupta, Y. K.; Choudhury, R. K.

    2009-03-01

    The quasi-elastic scattering measurements for 18O+58,62Ni systems have been carried out at Θlab = 150° around Coulomb barrier energies to investigate the effect of nuclear shell closure on the barrier distributions. The 18O+58Ni system leads to N = 40 neutron shell closure and 18O+62Ni system is having N = 44 in the compound system. It is observed that target 2+ and 3-, projectile 2+ inelastic and 2n-transfer couplings are required in coupled-channels fusion model (CCFULL) calculations to get good comparison with the experimental barrier distribution of 18O+62Ni system, whereas projectile 2+ inelastic state coupling is not required for 18O+58Ni system. However, the low energy structure observed in the barrier distribution of 18O+58Ni system is not reproduced by coupled-channels calculations. This suggests, a possible additional effect due to N = 40 shell closure in the compound system not accounted for in coupled-channels calculations.

  15. Performance Assessment Program for the Savannah River Site Liquid Waste Facilities - 13610

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberger, Kent H.

    2013-07-01

    The Liquid Waste facilities at the U.S. Department of Energy's (DOE) Savannah River Site (SRS) are operated by Liquid Waste Operations contractor Savannah River Remediation LLC (SRR). A separate Performance Assessment (PA) is prepared to support disposal operations at the Saltstone Disposal Facility and closure evaluations for the two liquid waste tank farm facilities at SRS, F-Tank Farm and H-Tank Farm. A PA provides the technical basis and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements identified in operations and closure regulatory guidance. The Saltstone Disposal Facility is subject to a State of Southmore » Carolina industrial solid waste landfill permit and the tank farms are subject to a state industrial waste water permit. The three Liquid Waste facilities are also subject to a Federal Facility Agreement approved by the State, DOE and the Environmental Protection Agency (EPA). Due to the regulatory structure, a PA is a key technical document reviewed by the DOE, the State of South Carolina and the EPA. As the waste material disposed of in the Saltstone Disposal Facility and the residual material in the closed tank farms is also subject to reclassification prior to closure via a waste determination pursuant to Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005, the U.S. Nuclear Regulatory Commission (NRC) is also a reviewing agency for the PAs. Pursuant to the Act, the NRC also has a continuing role to monitor disposal actions to assess compliance with stated performance objectives. The Liquid Waste PA program at SRS represents a continual process over the life of the disposal and closure operations. When the need for a PA or PA revision is identified, the first step is to develop a conceptual model to best represent the facility conditions. The conceptual model will include physical dimensions of the closed system, both the engineered and natural system, and modeling input parameters associated with the modeled features, both initial values (at the time of facility closure) and degradation rates/values. During the development of the PA, evaluations are conducted to reflect not only the results associated with the best available information at the time but also to evaluate potential uncertainties and sensitivities associated with the modeled system. While the PA will reflect the modeled system results from the best available information, it will also identify areas for future work to reduce overall PA uncertainties moving forward. DOE requires a PA Maintenance Program such that work continues to reduce model uncertainties, thus bolstering confidence in PA results that support regulatory decisions. This maintenance work may include new Research and Development activities or modeling as informed by previous PA results and other new information that becomes available. As new information becomes available, it is evaluated against previous PAs and appropriate actions are taken to ensure continued confidence in the regulatory decisions. Therefore, the PA program is a continual process that is not just the development of a PA but seeks to incorporate new information to reduce overall model uncertainty and provide continuing confidence in regulatory decisions. (author)« less

  16. Concomitant surgical closure of left atrial appendage: A systematic review and meta-analysis.

    PubMed

    Ando, Masahiko; Funamoto, Masaki; Cameron, Duke E; Sundt, Thoralf M

    2018-03-12

    Although percutaneous closure of the left atrial appendage is supported as a potential alternative to lifelong anticoagulation in patients with atrial fibrillation, comprehensive evidence on surgical left atrial appendage closure in heart surgery is limited. We conducted a meta-analysis of studies comparing patients who underwent open cardiac surgery with or without left atrial appendage closure. A literature search was performed on PubMed, Embase, and Cochrane Trials databases. Outcomes of interest were 30-day/in-hospital mortality and cerebrovascular accident. I 2 statistics were used to evaluate heterogeneity, and publication bias was evaluated by Begg's and Egger's tests. We reviewed 1284 articles and selected for main analysis 7 articles including 3897 patients (1963 in the left atrial appendage closure group and 1934 in the non-left atrial appendage closure group). Among the 7 studies, 3 were randomized-controlled studies, 3 were propensity-matched studies, and 1 was a case-matching study. At 30-day/in-hospital follow-up, left atrial appendage closure was significantly associated with decreased risk of mortality and cerebrovascular accident (odds ratio, 0.384, 95% confidence interval, 0.233-0.631 for mortality, and odds ratio, 0.622, 95% confidence interval, 0.388-0.998 for cerebrovascular accident). Stratified analysis demonstrated that this association was more prominent in preoperative atrial fibrillation strata. Concomitant surgical left atrial appendage closure should be considered at the time of open cardiac surgery, particularly among those in atrial fibrillation preoperatively. The benefit of left atrial appendage closure for patients not in atrial fibrillation and for those undergoing nonvalvular surgery is still unclear. Further prospective investigations are indicated. Copyright © 2018. Published by Elsevier Inc.

  17. Endoscopic closure of duodenal perforations by using an over-the-scope clip: a randomized, controlled porcine study.

    PubMed

    von Renteln, Daniel; Rudolph, Hans-Ulrich; Schmidt, Arthur; Vassiliou, Melina C; Caca, Karel

    2010-01-01

    Duodenal perforations during diagnostic upper endoscopy are rare; however, when therapeutic techniques are performed, the reported incidence is as great as 2.8%. Surgical repair is usually mandated, but it is associated with significant morbidity and mortality. To compare closure of duodenal perforations by using an over-the-scope clip (OTSC) with a surgical closure. Randomized, controlled animal study. Animal facility laboratory. Domestic pigs (24 females). Large (10-mm) duodenal perforations were created by using an endoscopic needle-knife. The animals were randomly assigned to either open surgical repair (n=12) or endoscopic closure by using the OTSC system (n=12). Pressurized leak tests were performed during necropsy. One major bleed occurred because of a liver injury during creation of the duodenotomy. Mean time for endoscopic closure was 5 minutes (range, 3-8 min; SD +/- 2). No complications occurred during any of the closure procedures. At necropsy, all OTSC and surgical closures demonstrated complete sealing of duodenotomy sites. Pressurized leak tests demonstrated a mean burst pressure of 166 mm Hg (range, 80-260; SD +/- 65) for OTSC closures and 143 mm Hg (range, 30-300, SD +/- 83) for surgical sutures. Ex vivo intact duodenal specimens exhibited a mean burst pressure of 247 mm Hg (range, 200-300; SD +/- 35), which was significantly higher compared with in vivo OTSC and surgical closures (P < .01). There were no significant differences between burst pressures of OTSC and surgical closures (P = .461). Nonsurvival setting. Endoscopic closure of duodenal perforations by using the OTSC system is comparable with surgical closure in a nonsurvival porcine model. This technique is easy to perform and seems suitable for repairing duodenal perforations. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  18. Occupancy estimation and the closure assumption

    USGS Publications Warehouse

    Rota, Christopher T.; Fletcher, Robert J.; Dorazio, Robert M.; Betts, Matthew G.

    2009-01-01

    1. Recent advances in occupancy estimation that adjust for imperfect detection have provided substantial improvements over traditional approaches and are receiving considerable use in applied ecology. To estimate and adjust for detectability, occupancy modelling requires multiple surveys at a site and requires the assumption of 'closure' between surveys, i.e. no changes in occupancy between surveys. Violations of this assumption could bias parameter estimates; however, little work has assessed model sensitivity to violations of this assumption or how commonly such violations occur in nature. 2. We apply a modelling procedure that can test for closure to two avian point-count data sets in Montana and New Hampshire, USA, that exemplify time-scales at which closure is often assumed. These data sets illustrate different sampling designs that allow testing for closure but are currently rarely employed in field investigations. Using a simulation study, we then evaluate the sensitivity of parameter estimates to changes in site occupancy and evaluate a power analysis developed for sampling designs that is aimed at limiting the likelihood of closure. 3. Application of our approach to point-count data indicates that habitats may frequently be open to changes in site occupancy at time-scales typical of many occupancy investigations, with 71% and 100% of species investigated in Montana and New Hampshire respectively, showing violation of closure across time periods of 3 weeks and 8 days respectively. 4. Simulations suggest that models assuming closure are sensitive to changes in occupancy. Power analyses further suggest that the modelling procedure we apply can effectively test for closure. 5. Synthesis and applications. Our demonstration that sites may be open to changes in site occupancy over time-scales typical of many occupancy investigations, combined with the sensitivity of models to violations of the closure assumption, highlights the importance of properly addressing the closure assumption in both sampling designs and analysis. Furthermore, inappropriately applying closed models could have negative consequences when monitoring rare or declining species for conservation and management decisions, because violations of closure typically lead to overestimates of the probability of occurrence.

  19. The impact of primary packaging on the quality of parenteral products.

    PubMed

    Solomun, Ljiljana; Ibric, Svetlana; Boltic, Zorana; Djuric, Zorica; Stupar, Biljana

    2008-11-04

    The unique approach in manufacturing of pharmaceutical dosage forms of active substances known to be unstable in aqueous solution is the introduction of lyophilization process. Nevertheless, these products must be reconstituted using the diluent from a separate container before application. The possible solution for this problem is the application of dual chamber vials comprising the freeze-dried product in a lower compartment of the vial and the solution for reconstitution in the upper chamber. The main issue in development of such product is the choice of contact packaging (rubber closures, glass vials and the container closure system as a whole). The most important parameter used for evaluation of the influence of contact material on product quality was the pH value. The results have shown that the type of vials (moulded or tubular glass) has no impact on pH shift of the solution for reconstitution (tested solution-TS), while significant differences in pH value of the TS were observed depending on the rubber closures formulation used (with some formulations, the pH shift during the test was 6.5-9.14). Benzyl alcohol assay during the tests remained unchanged. Integrity tests of the container closure system (CCS) have demonstrated the adequacy of the selected packaging system. The quality of the CCS of choice was confirmed in the course of stability studies, only parameters directly influenced by CCS being presented in this work: loss on drying and pH value. On the basis of these results, no changes in loss on drying were connected to CCS, and the pH value of the reconstituted solution remains unchanged in samples tested both ex-tempore and after in-use period of 48 h.

  20. The etiology and determinants of hospital closure.

    PubMed

    Longo, D R; Sohn, M W; Shortell, S M

    1996-01-01

    This article examines the etiology of hospital closure and the correlates of hospital closure and the extent of similarity in this organizational outcome between pre- and post-Prospective Payment System (PPS) implementation. It also replicates a study from an earlier time period. Findings support the study's main hypotheses: in more stringent and turbulent markets, institutional and strategic variables are more important determinants of hospital closure. Merger acquisitions are found to be similar to both system acquisitions and autonomous hospitals. Standard Metropolitan Statistical Area (SMSA) status and regulation show an effect on hospital closure and merger acquisition. While many similarities exist when compared to the replicated study and findings prior to PPS implementation, it appears that sufficient differences exist to support the hypothesis that the PPS has an impact upon hospital organizational outcome.

  1. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.

    PubMed

    Simonetti, Andrea; Amari, Filippo

    2015-01-01

    In reaction to the limitations of the traditional sterility test methods, in 2008, the U.S. Food and Drug Administration issued the guidance "Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products" encouraging sterile drug manufacturers to use properly validated physical methods, apart from conventional microbial challenge testing, to confirm container closure integrity as part of the stability protocol. The case study presented in this article investigated the capability of four container closure integrity testing methods to detect simulated defects of different sizes and types on glass syringes, prefilled both with drug product intended for parenteral administration and sterile water. The drug product was a flu vaccine (Agrippal, Novartis Vaccines, Siena, Italy). Vacuum decay, pharmacopoeial dye ingress test, Novartis specific dye ingress test, and high-voltage leak detection were, in succession, the methods involved in the comparative studies. The case study execution was preceded by the preparation of two independent sets of reference prefilled syringes, classified, respectively, as examples of conforming to closure integrity requirements (negative controls) and as defective (positive controls). Positive controls were, in turn, split in six groups, three of with holes laser-drilled through the prefilled syringe glass barrel, while the other three with capillary tubes embedded in the prefilled syringe plunger. These reference populations were then investigated by means of validated equipment used for container closure integrity testing of prefilled syringe commercial production; data were collected and analyzed to determine the detection rate and the percentage of false results. Results showed that the vacuum decay method had the highest performance in terms of detection sensitivity and also ensured the best reliability and repeatability of measurements. An innovative technical solution, preventing possible prefilled syringe plunger movement during container closure integrity testing execution, is presented as well. The growing need to meet sterile drug products' regulatory, quality, and safety expectations has progressively driven new developments and improvements both in container closure integrity testing methods and in the respective equipment, over the last years. Indeed, container closure integrity testing establishes the container closure system capability to provide required protection to the drug product and to demonstrate maintenance of product sterility over its shelf life. This article describes the development of four container closure integrity testing approaches for the evaluation of glass prefilled syringe closure integrity, including two destructive (pharmacopoeial and Novartis specific dye ingress test) and two non-destructive (vacuum decay and high-voltage leak detection) methods. The important finding from the validation of comparative studies was that the vacuum decay method resulted in the most effective, reliable and repeatable detection of defective samples, whether the defect was exposed to sterile water, to drug product, or to air. Complete sets of known defects were created for this purpose (5 μm, 10 μm, 20 μm certified leakages by laser drilled holes and capillary tubes). All investigations and studies were conducted at Bonfiglioli Engineering S.r.l. (Vigarano Pieve, Ferrara, Italy) and at Novartis Vaccines (Sovicille, Siena, Italy). © PDA, Inc. 2015.

  2. Meta-analysis of the Efficacy and Safety of Latanoprost Monotherapy in Patients With Angle-closure Glaucoma.

    PubMed

    Chen, Ru; Yang, Ke; Zheng, Zhong; Ong, Moh-Lim; Wang, Ning-Li; Zhan, Si-Yan

    2016-03-01

    To systematically evaluate the safety and efficacy of latanoprost monotherapy for the treatment of patients with angle-closure glaucoma. We searched EMBASE, Medline, Cochrane Library, Chinese Journal Full-text Database (CNKI), Chinese Science and Technology Periodical Database (VIP), and Wang Fang using the search terms "latanoprost" (or its commercial name, Xalatan) and "angle-closure glaucoma." Resulting articles were then screened using preset inclusion criteria. Subgroup and sensitivity analyses were performed to evaluate the impact of research population, research type (blinded or controlled), and withdrawal/loss to follow-up. A total of 17 studies (n=807) were included in this meta-analysis. The primary outcome measure was intraocular pressure (IOP). Changes in the mean, peak, and trough IOP from baseline were used as effect measures. As I statistic revealed statistical heterogeneity, the random-effects model was applied. With the exception of 2 non-Asian populations from Australia and Peru, all 13 countries included in this study were from Asia. Latanoprost reduced mean IOP by 7.9 mm Hg (32.4%), peak IOP by 7.4 mm Hg (29.8%), and trough IOP by 7.9 mm Hg (32.5%). The most frequent ocular adverse effects were ocular hyperemia, discomfort (including eye irritation, ocular discomfort, foreign body sensation, and itching), and blurred vision with a total incidence rate of 9.4%, 8.7%, and 5.2%, respectively. Systemic adverse effects encompass rhinitis, dizziness, headache, and nonspecific skin pigmentation. Latanoprost is effective at reducing the IOP of patients with angle-closure glaucoma. Adverse reactions associated with latanoprost were mainly ocular in nature.

  3. 40 CFR 264.310 - Closure and post-closure care.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... settling, subsidence, erosion, or other events; (2) Continue to operate the leachate collection and removal system until leachate is no longer detected; (3) Maintain and monitor the leak detection system in...

  4. 40 CFR 264.310 - Closure and post-closure care.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... settling, subsidence, erosion, or other events; (2) Continue to operate the leachate collection and removal system until leachate is no longer detected; (3) Maintain and monitor the leak detection system in...

  5. 40 CFR 264.310 - Closure and post-closure care.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... settling, subsidence, erosion, or other events; (2) Continue to operate the leachate collection and removal system until leachate is no longer detected; (3) Maintain and monitor the leak detection system in...

  6. 40 CFR 264.310 - Closure and post-closure care.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... settling, subsidence, erosion, or other events; (2) Continue to operate the leachate collection and removal system until leachate is no longer detected; (3) Maintain and monitor the leak detection system in...

  7. 40 CFR 264.310 - Closure and post-closure care.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... settling, subsidence, erosion, or other events; (2) Continue to operate the leachate collection and removal system until leachate is no longer detected; (3) Maintain and monitor the leak detection system in...

  8. Intraoperative angiography provides objective assessment of skin perfusion in complex knee reconstruction.

    PubMed

    Wyles, Cody C; Taunton, Michael J; Jacobson, Steven R; Tran, Nho V; Sierra, Rafael J; Trousdale, Robert T

    2015-01-01

    Wound necrosis is a potentially devastating complication of complex knee reconstruction. Laser-assisted indocyanine green angiography (LA-ICGA) is a technology that has been described in the plastic surgery literature to provide an objective assessment of skin perfusion in the operating room. This novel technology uses a plasma protein bound dye (ICG) and a camera unit that is calibrated to view the frequency emitted by the dye. The intention of this technology is to offer real-time visualization of blood flow to skin and soft tissue in a way that might help surgeons make decisions about closure or coverage of a surgical site based on blood flow, potentially avoiding soft tissue reconstruction while preventing skin necrosis or wound breakdown after primary closures, but its efficacy is untested in the setting of complex TKA. The purpose of this study was to evaluate perfusion borders and tension ischemia in a series of complex knee reconstructions to guide optimal wound management. Beginning in mid-2011, an LA-ICGA system was used to evaluate soft tissue viability in knee reconstruction procedures that were considered high risk for wound complications. Seven patients undergoing complex primary or revision TKA from 2011 to 2013 were included. These patients were chosen as a convenience sample of knee reconstruction procedures for which we obtained consultation with the plastic surgery service. The perfusion of skin and soft tissue coverage was evaluated intraoperatively for all patients with the LA-ICGA system, and the information was used to guide wound management. Followup was at a mean of 9 months (range, 6-17 months), no patients were lost to followup, and the main study endpoint was uneventful healing of the surgical incision. All seven closures went on to heal without necrosis. One patient, however, was subsequently revised for a deep periprosthetic infection 4 months after their knee reconstruction and underwent flap coverage at the time of that revision. Implementation of LA-ICGA provides an objective intraoperative assessment of soft tissue perfusion. This technology may help guide the surgeon's decisions about wound closure in real-time to accommodate the perfusion challenges unique to each patient. Specifically, patients with medical risk factors for poor perfusion or wound healing (such as diabetes, peripheral vascular disease, tobacco use, corticosteroid therapy, infection) or anatomical/surgical risk factors (ie, previous surgery about the reconstruction site, trauma wounds, or reconstruction of severe deformity) may benefit from objective intraoperative information regarding perfusion of the wound site. Furthermore, LA-ICGA could be used to prospectively evaluate the physiologic impact of different wound closure techniques. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  9. Proppant flowback control additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, P.D.; Weaver, J.D.; Parker, M.A.

    1996-12-31

    This paper describes the laboratory and field development of thermoplastic film materials used to reduce proppant flowback that can occur after fracturing treatments. The paper provides a summary of flowback mechanism theories and laboratory tests comparing flowback tendency for various types of treating procedures and materials. Some of these materials include angular proppant, proppant/fiber mixtures, and proppant with film strips tested over a wide range of temperature, closure stress, and flow-rate conditions. Field treatment procedures are discussed, and several case histories are presented. All of the methods evaluated were effective in reducing proppant flowback under certain conditions. Heat-shrink film cutmore » into thin slivers proved to provide flowback reduction over broad temperature and closure stress ranges and was found to cause little impairment to fracture conductivity with some dependency on use concentration, temperature, and closure stress. The film materials were more resistant to damage caused by blending and pumping than all other materials evaluated. In addition, proppant packs, including consolidated packs, were significantly more tolerant of large, repeated stress changes. Field results indicate that the use of the heat-shrink film material as a flowback control agent permits more aggressive bean-up procedures following conventional fracturing treatments. Conventional dry-additive metering systems were used to add the film material to the fracturing fluid proppant slurry.« less

  10. Evaluating the use of fibrin glue for sealing low-output enterocutaneous fistulas: study protocol for a randomized controlled trial.

    PubMed

    Wu, Xiuwen; Ren, Jianan; Wang, Gefei; Wang, Jianzhong; Wang, Feng; Fan, Yueping; Li, Yuanxin; Han, Gang; Zhou, Yanbing; Song, Xiaofei; Quan, Bin; Yao, Min; Li, Jieshou

    2015-10-07

    The management of an enterocutaneous fistula poses a significant challenge to surgeons and is often associated with a costly hospital stay and long-term discomfort. The use of fibrin glue in the fistula tract has been shown to promote closure of low output enterocutaneous fistulas. Our previous nonrandomized study demonstrated that autologous platelet-rich fibrin glue treatment significantly decreased time to fistula closure and promoted closure rates. However, there are several limitations in the study, which may lead to bias in our conclusion. Thus, a multicenter, randomized, controlled clinical trial is required. The study is designed as a randomized, open-label, three-arm, multicenter study in nine Chinese academic hospitals for evaluating the efficacy and safety of fibrin glue for sealing low-output fistulas. An established number of 171 fistula patients will undergo prospective random assignment to autologous fibrin glue, commercial porcine fibrin sealants or drainage cessation (1:1:1). The primary endpoint is fistula closure time (defined as the interval between the day of enrollment and day of fistula closure) during the 14-day treatment period. To our knowledge, this is the first study to evaluate the safety and efficacy of both autologous and commercial fibrin glue sealing for patients with low-output volume fistulas. NCT01828892 . Registration date: April 2013.

  11. A review of near-wall Reynolds-stress

    NASA Technical Reports Server (NTRS)

    So, R. M. C.; Lai, Y. G.; Zhang, H. S.; Hwang, B. C.

    1991-01-01

    The advances made in second-order near-wall turbulence closures are summarized. All closures examined are based on some form of high Reynolds number models for the Reynolds stress and the turbulent kinetic energy dissipation rate equations. Consequently, most near-wall closures proposed to data attempt to modify the high Reynolds number models for the dissipation rate equation so that the resultant models are applicable all the way to the wall. The near-wall closures are examined for their asymptotic behavior so that they can be compared with the proper near-wall behavior of the exact equations. A comparison of the closure's performance in the calculation of a low Reynolds number plane channel flow is carried out. In addition, the closures are evaluated for their ability to predict the turbulence statistics and the limiting behavior of the structure parameters compared to direct simulation data.

  12. Evaluation of Sorbents for Acetylene Separation in Atmosphere Revitalization Loop Closure

    NASA Technical Reports Server (NTRS)

    Abney, Morgan B.; Miller, Lee A.; Barton, Katherine

    2012-01-01

    State-of-the-art carbon dioxide reduction technology uses a Sabatier reactor to recover water from metabolic carbon dioxide. In order to maximize oxygen loop closure, a byproduct of the system, methane, must be reduced to recover hydrogen. NASA is currently exploring a microwave plasma methane pyrolysis system for this purpose. The resulting product stream of this technology includes unreacted methane, product hydrogen, and acetylene. The hydrogen and the small amount of unreacted methane resulting from the pyrolysis process can be returned to the Sabatier reactor thereby substantially improving the overall efficiency of the system. However, the acetylene is a waste product that must be removed from the pyrolysis product. Two materials have been identified as potential sorbents for acetylene removal: zeolite 4A, a commonly available commercial sorbent, and HKUST-1, a newly developed microporous metal. This paper provides an explanation of the rationale behind acetylene removal and the results of separation testing with both materials

  13. Evaluation of Sorbents for Acetylene Separation in Atmosphere Revitalization Loop Closure

    NASA Technical Reports Server (NTRS)

    Abney, Morgan B.; Miller, Lee A.; Barton, Katherine

    2011-01-01

    State-of-the-art carbon dioxide reduction technology uses a Sabatier reactor to recover water from metabolic carbon dioxide. In order to maximize oxygen loop closure, a byproduct of the system, methane, must be reduced to recover hydrogen. NASA is currently exploring a microwave plasma methane pyrolysis system for this purpose. The resulting product stream of this technology includes unreacted methane, product hydrogen, and acetylene. The hydrogen and the small amount of unreacted methane resulting from the pyrolysis process can be returned to the Sabatier reactor thereby substantially improving the overall efficiency of the system. However, the acetylene is a waste product that must be removed from the pyrolysis product. Two materials have been identified as potential sorbents for acetylene removal: zeolite 4A, a commonly available commercial sorbent, and HKUST-1, a newly developed microporous metal. This paper provides an explanation of the rationale behind acetylene removal and the results of separation testing with both materials.

  14. 300 Area waste acid treatment system closure plan. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-03-01

    This section provides a description of the Hanford Site, identifies the proposed method of 300 Area Waste Acid Treatment System (WATS) closure, and briefly summarizes the contents of each chapter of this plan.

  15. Perventricular double-device closure of wide-spaced multi-hole perimembranous ventricular septal defect.

    PubMed

    Liang, Fei; Hongxin, Li; Zhang, Hai-Zhou; Wenbin, Guo; Zou, Cheng-Wei; Farhaj, Zeeshan

    2017-04-17

    Device closure of a wide-spaced multi-hole PmVSD is difficult to succeed in percutaneous approach. This study is to evaluate the feasibility, safety and efficacy of perventricular device closure of wide-spaced multi-hole PmVSD using a double-device implanting technique. Sixteen patients with wide-spaced multi-hole PmVSD underwent perventricular closure with two devices through an inferior median sternotomy approach under transesophageal echocardiographic guidance. The largest hole and its adjacent small holes were occluded with an optimal-sized device. The far-away residual hole was occluded with the other device using a probe-assisted delivery system. All patients were followed up for a period of 1 to 4 years to determine the residual shunt, atrioventricular block and the adjacent valvular function. The number of the holes of the PmVSD was 2 to 4. The maximum distance between the holes was 5.0 to 10.0 mm (median, 6.4 mm). The diameter of the largest hole was 2.5 to 7.0 mm (median, 3.6 mm). The success rate of double-device closure was 100%. Immediate residual shunts were found in 6 patients (38%), and incomplete right bundle branch block at discharge occurred in 3 cases (19%). Both complications decreased to 6% at 1-year follow-up. Neither of them had a severe device-related complication. Perventricular closure of a wide-spaced multi-hole PmVSD using a double-device implanting technique is feasible, safe, and efficacious. In multi-hole PmVSDs with the distance between the holes of more than 5 mm, double-device implantation may achieve a complete occlusion.

  16. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    PubMed

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P < .0001, Wilcoxon signed rank test). Overall, gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  17. The influence of injury severity on complication rates after primary closure or colostomy for penetrating colon trauma.

    PubMed Central

    Nelken, N; Lewis, F

    1989-01-01

    The management of penetrating colon injury has been frequently debated in the literature, yet few reports have evaluated primary closure versus diverting colostomy in similarly injured patients. Diverting colostomy is the standard of care when mucosal penetration is present, but primary closure in civilian practice has generally had excellent results, although it has been restricted to less severely injured patients. Because the degree of injury may influence choice of treatment in modern practice, various indices of injury severity have been proposed for assessment of patients with penetrating colon trauma. As yet, however, there has been no cross-comparison of repair type versus injury severity. A retrospective study 76 patients who sustained penetrating colon trauma between January 1, 1979 and December 31, 1985 and who survived for at least 24 hours was conducted. Different preferences among attending surgeons and a more aggressive approach to the use of primary closure during the years of study led to an essentially random use of primary closure and diverting colostomy for moderate levels of colon injury, with mandatory colostomy reserved for the most serious injuries. Primary closure was performed in 37 patients (three having resection and anastomosis), and colostomy was performed in 39 patients. Severity of injury was evaluated by the Injury Severity Score (ISS), Penetrating Abdominal Trauma Index (PATI), and the Flint Colon Injury Score. Complications and outcome were evaluated as a function of severity of injury, and primary closure and colostomy were compared. Demographic profiles of the two groups did not differ regarding age, sex, mechanism of injury, shock, or delay between injury and operation. The mortality rate was 2.6% for each group. Major morbidity, including septic complications, occurred in 11% of the patients of the primary closure group and in 49% of those of the colostomy group. When PATI was less than 25, the Flint score was less than or equal to 2, or when the ISS was less than 25, primary closure resulted in fewer complications than did colostomy. Of the injury severity indices examined, the PATI most reliably predicted complications and specifically identified patients who whose outcome would be good with primary repair. These results suggest that the use of primary closure should be expanded in civilian penetrating colon trauma and that, even with moderate degrees of colon injury, primary closure provides an outcome equivalent to that provided by colostomy. In addition, the predictive value of the PATI suggests that it should be included along with other injury severity indices in trauma data bases. Images Fig. 3. Fig. 4. PMID:2930290

  18. Improvement of tricuspid regurgitation after transcatheter ASD closure in older patients.

    PubMed

    Chen, L; Shen, J; Shan, X; Wang, F; Kan, T; Tang, X; Zhao, X; Qin, Y

    2017-07-19

    Adult patients with undiagnosed atrial septal defect (ASD) may have right heart cavity enlargement and functional tricuspid valve insufficiency. Moderate or more severe tricuspid regurgitation has been associated with a worse prognosis, and more serious complications are typically seen in older patients. This study aimed to evaluate the improvement in functional tricuspid regurgitation and heart geometry after transcatheter ASD closure in older patients. The data of 111 patients over 60 years of age with moderate or severe tricuspid regurgitation before ASD closure were analyzed. At the 1‑month and 6‑month follow-up after closure, both tricuspid regurgitation jet area and right atrial volume decreased significantly. Right ventricular volume decreased 1 month after closure, showing a further decrease at the end of the 6‑month follow-up. However, 24 patients (21.6%) still had persistent severe tricuspid regurgitation after the procedure. Multivariate analysis revealed that patient age at ASD closure and pulmonary artery systolic pressure determined by echocardiography before closure were predictors of persistent tricuspid regurgitation after closure. Transcatheter ASD closure in older patients could significantly decrease tricuspid regurgitation and improve right heart geometry.

  19. Assessment of a simple, novel endoluminal method for gastrotomy closure in NOTES.

    PubMed

    Lee, Sang Soo; Oelschlager, Brant K; Wright, Andrew S; Soares, Renato V; Sinan, Huseyin; Montenovo, Martin I; Hwang, Joo Ha

    2011-10-01

    A reliable method for gastrotomy closure in NOTES will be essential for NOTES to become viable clinically. However, methods using existing and widely available endoscopic accessories have been ineffective. The objective of this study was to evaluate the feasibility and safety of a new simple method for gastric closure (retracted clip-assisted loop closure) that uses existing endoscopic accessories with minor modifications. The retracted clip-assisted loop closure technique involves deploying 3-4 Resolution(®) clips (modified by attaching a 90-cm length of suture to the end of each clip) along the margin of the gastrotomy with one jaw on the serosal surface and the other jaw on the mucosal surface. The suture strings are threaded through an endoloop. Traction is then applied to the strings causing the gastric wall to tent. The endoloop is secured below the tip of the clips, completing a full-thickness gastrotomy closure. The main outcome measures were feasibility, efficacy, and safety of the new retracted clip-assisted loop closure technique for NOTES gastrotomy closure. An air-tight seal was achieved in 100% (n = 9) of stomachs. The mean leak pressure was 116.3 (±19.4) mmHg. The retracted clip-assisted loop closure technique can be used to perform NOTES gastrotomy closure by using existing endoscopic accessories with minor modifications.

  20. Percutaneous closure of patent ductus arteriosus in children: Immediate and short-term changes in left ventricular systolic and diastolic function.

    PubMed

    Gupta, Saurabh Kumar; Krishnamoorthy, Km; Tharakan, Jaganmohan A; Sivasankaran, S; Sanjay, G; Bijulal, S; Anees, T

    2011-07-01

    To evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA) on left ventricular (LV) systolic and diastolic function in children. Limited studies are available on alteration in LV hemodynamics, especially diastolic function, after PDA closure. Thirty-two consecutive children with isolated PDA treated by trans-catheter closure were studied. The LV systolic and diastolic function were assessed by two-dimensional (2D) echocardiography and tissue Doppler imaging 1 day before the PDA closure, on day 1, and on follow-up. At baseline, none of the patients had LV systolic dysfunction. On day 1 post-PDA closure, 8 (25%) children developed LV systolic dysfunction. The baseline LV ejection fraction (LVEF), LV end-systolic dimension (LVESD), and PDA diastolic gradient predicted the post-closure LVEF. Patients who developed post-closure LV systolic dysfunction had poorer LV diastolic function than those who did not. LV diastolic properties improved after PDA closure; however, the improvement in LV diastolic properties lagged behind the improvement in the LV systolic function. All children were asymptomatic and had normal LVEF on follow up of >3 months. Percutaneous closure of PDA is associated with the reversible LV systolic dysfunction. Improvement in the LV diastolic function lags behind that in the LV systolic function.

  1. Analytic closures for M1 neutrino transport

    DOE PAGES

    Murchikova, E. M.; Abdikamalov, E.; Urbatsch, T.

    2017-04-25

    Carefully accounting for neutrino transport is an essential component of many astrophysical studies. Solving the full transport equation is too expensive for most realistic applications, especially those involving multiple spatial dimensions. For such cases, resorting to approximations is often the only viable option for obtaining solutions. One such approximation, which recently became popular, is the M1 method. It utilizes the system of the lowest two moments of the transport equation and closes the system with an ad hoc closure relation. The accuracy of the M1 solution depends on the quality of the closure. Several closures have been proposed in themore » literature and have been used in various studies. We carry out an extensive study of these closures by comparing the results of M1 calculations with precise Monte Carlo calculations of the radiation field around spherically symmetric protoneutron star models. We find that no closure performs consistently better or worse than others in all cases. The level of accuracy that a given closure yields depends on the matter configuration, neutrino type and neutrino energy. As a result, given this limitation, the maximum entropy closure by Minerbo on average yields relatively accurate results in the broadest set of cases considered in this work.« less

  2. Type of closure prevents microbial contamination of cosmetics during consumer use.

    PubMed Central

    Brannan, D K; Dille, J C

    1990-01-01

    The dispensing closure used for containers plays an important role in protecting cosmetics from in-use microbial contamination. This hypothesis was tested by aseptically packing unpreserved shampoo and skin lotion into containers with three different closure types which provided various degrees of protection against consumer and environmental microbial insults. Shampoo was packed in containers with slit-cap (n = 25), flip-cap (n = 25), or screw-cap (n = 28) closures. Skin lotion was packed in containers with pump-top (n = 21), flip-cap (n = 18), or screw-cap (n = 21) closures. The products were then used by volunteers under actual in-use conditions for 3 (shampoo) or 2 (skin lotion) weeks. After use, the products were evaluated for microbial contamination by using standard methods for enumeration and identification. The standard screw-cap closure provided only minimal protection against microbial contamination of both the shampoo (29% contamination incidence) and the skin lotion (71%). The slit-cap closure on the shampoo container and the flip-cap closure on the skin lotion container provided slightly enhanced degrees of protection (21 and 39% contamination incidence, respectively). The greatest amount of protection (i.e., lowest contamination incidence) was provided by the flip-cap closure for the shampoo container (0%) and the pump-top closure for the skin lotion container (10%). As a result, closure type plays an important role in protecting poorly preserved products from in-use microbial contamination. Images PMID:2339896

  3. Contemporary Approach to the Diagnosis and Management of Primary Angle-Closure Disease.

    PubMed

    Razeghinejad, M Reza; Myers, Jonathan S

    2018-05-16

    Primary angle closure disease spectrum varies from a narrow angle to advanced glaucoma. A variety of imaging technologies may assist the clinician in determining the pathophysiology and diagnosis of primary angle closure, but gonioscopy remains a mainstay of clinical evaluation. Laser iridotomy effectively eliminates the pupillary block component of angle closure; however, studies show that in many patients the iridocorneal angle remains narrow from underlying anatomic issues, and increasing lens size often leads to further narrowing over time. Recent studies have further characterized the role of the lens in angle closure disease, and cataract or clear lens extraction is increasingly used earlier in its management. As a first surgical step in angle closure glaucoma, lens extraction alone often effectively controls the pressure with less risk of complications than concurrent or stand alone glaucoma surgery, but may not be sufficient in more advanced or severe disease. We provide a comprehensive review on the primary angle-closure disease nomenclature, imaging, and current laser and surgical management. Copyright © 2018. Published by Elsevier Inc.

  4. Reducing the risk of contamination of sterile parenteral products via ready-to-use closure components.

    PubMed

    Curry, Wayne; Conway, Samuel; Goodfield, Clara; Miller, Kimberly; Mueller, Ronald L; Polini, Eugene

    2010-12-01

    The preparation of sterile parenteral products requires careful control of all ingredients, materials, and processes to ensure the final product has the identity and strength, and meets the quality and purity characteristics that it purports to possess. Contamination affecting these critical properties of parenteral products can occur in many ways and from many sources. The use of closures supplied by manufacturers in a ready-to-use state can be an effective method for reducing the risk of contamination and improving the quality of the drug product. This article will address contamination attributable to elastomeric container closure components and the regulatory requirements associated with container closure systems. Possible contaminants, including microorganisms, endotoxins, and chemicals, along with the methods by which these contaminants can enter the product will be reviewed. Such methods include inappropriate material selection, improper closure preparation processes, compromised container closure integrity, degradation of closures, and leaching of compounds from the closures.

  5. Comparison of V-Loc™ 180 wound closure device and Quill™ PDO knotless tissue-closure device for intradermal closure in a porcine in vivo model: evaluation of biomechanical wound strength.

    PubMed

    Gingras, Kristen; Zaruby, Jeffrey; Maul, Don

    2012-05-01

    The objective of this study was to compare the biomechanical strength of two barbed suture devices: V-Loc™ 180 Wound Closure Device and Quill™ PDO Knotless Tissue-Closure Device following primary cosmetic skin closures in a porcine dermal model. This prospective randomized, controlled in vivo trial compared size 3/0 V-Loc™ 180 device to size 2/0 Quill™ PDO device. Both products were tested for dermal closure in adult porcine models and evaluated at five timepoints. At postoperative days 0, 3, 7, 14, and 28 sutured tissue regions were excised post mortem and tested for intradermal wound holding strength. Wounds closed with V-Loc™ 180 device were stronger than Quill™ PDO device at days 0, 3, 7, and 14 with these differences being significant (p < 0.05) at days 3 and 7. At day 3, the average maximum load of V-Loc™ 180 was 13.53 kgf and Quill™ PDO was 10.38 kgf (p = 0.002). At day 7, the average maximum load of V-Loc™ 180 was 10.4 kgf and Quill™ PDO was 7.56 kgf (p = 0.001). Throughout the duration of the study, there was no suture extrusion or tissue distortion and all wounds healed with no major complications. In this study, V-Loc™ 180 device was significantly stronger than Quill™ PDO device during the critical phases of wound healing in skin. Copyright © 2012 Wiley Periodicals, Inc.

  6. WASTE PACKAGE REMEDIATION SYSTEM DESCRIPTION DOCUMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    N.D. Sudan

    2000-06-22

    The Waste Package Remediation System remediates waste packages (WPs) and disposal containers (DCs) in one of two ways: preparation of rejected DC closure welds for repair or opening of the DC/WP. DCs are brought to the Waste Package Remediation System for preparation of rejected closure welds if testing of the closure weld by the Disposal Container Handling System indicates an unacceptable, but repairable, welding flaw. DC preparation of rejected closure welds will require removal of the weld in such a way that the Disposal Container Handling System may resume and complete the closure welding process. DCs/WPs are brought to themore » Waste Package Remediation System for opening if the Disposal Container Handling System testing of the DC closure weld indicates an unrepairable welding flaw, or if a WP is recovered from the subsurface repository because suspected damage to the WP or failure of the WP has occurred. DC/WP opening will require cutting of the DC/WP such that a temporary seal may be installed and the waste inside the DC/WP removed by another system. The system operates in a Waste Package Remediation System hot cell located in the Waste Handling Building that has direct access to the Disposal Container Handling System. One DC/WP at a time can be handled in the hot cell. The DC/WP arrives on a transfer cart, is positioned within the cell for system operations, and exits the cell without being removed from the cart. The system includes a wide variety of remotely operated components including a manipulator with hoist and/or jib crane, viewing systems, machine tools for opening WPs, and equipment used to perform pressure and gas composition sampling. Remotely operated equipment is designed to facilitate DC/WP decontamination and hot cell equipment maintenance, and interchangeable components are provided where appropriate. The Waste Package Remediation System interfaces with the Disposal Container Handling System for the receipt and transport of WPs and DCs. The Waste Handling Building System houses the system, and provides the facility, safety, and auxiliary systems required to support operations. The system receives power from the Waste Handling Building Electrical System. The system also interfaces with the various DC systems.« less

  7. Fatigue Crack Closure Analysis Using Digital Image Correlation

    NASA Technical Reports Server (NTRS)

    Leser, William P.; Newman, John A.; Johnston, William M.

    2010-01-01

    Fatigue crack closure during crack growth testing is analyzed in order to evaluate the critieria of ASTM Standard E647 for measurement of fatigue crack growth rates. Of specific concern is remote closure, which occurs away from the crack tip and is a product of the load history during crack-driving-force-reduction fatigue crack growth testing. Crack closure behavior is characterized using relative displacements determined from a series of high-magnification digital images acquired as the crack is loaded. Changes in the relative displacements of features on opposite sides of the crack are used to generate crack closure data as a function of crack wake position. For the results presented in this paper, remote closure did not affect fatigue crack growth rate measurements when ASTM Standard E647 was strictly followed and only became a problem when testing parameters (e.g., load shed rate, initial crack driving force, etc.) greatly exceeded the guidelines of the accepted standard.

  8. In vitro comparison of intra-abdominal hypertension development after different temporary abdominal closure techniques.

    PubMed

    Benninger, Emanuel; Labler, Ludwig; Seifert, Burkhardt; Trentz, Otmar; Menger, Michael D; Meier, Christoph

    2008-01-01

    To compare volume reserve capacity (VRC) and development of intra-abdominal hypertension after different in vitro temporary abdominal closure (TAC) techniques. A model of the abdomen was designed. The abdominal wall was simulated with polychloroprene, a synthetic rubber compound. A lentil-shaped defect of 150 cm(2) was cut into the anterior aspect of the abdominal wall. TAC of this defect was performed by a zipper system (ZS), a bag silo closure (BSC), or a vacuum assisted closure (VAC) with subatmospheric pressures ranging from 0- to 200 mmHg. The model with intact abdominal wall served as reference. The model was filled with water to baseline level. The intra-abdominal pressure was increased in 2 mmHg steps from baseline level (6 mmHg) to 40 mmHg by adding volume to the system according to a standardized protocol. VRC with corresponding intra-abdominal pressure were analyzed and compared for the different TAC techniques. VRC was the highest after BSC at all pressure levels studied (P < 0.05). VAC and ZS resulted in significantly lower VRC compared with BSC and reference (P < 0.05). The magnitude of negative pressure on the VAC did not significantly influence the VRC. In the present in vitro model, BSC demonstrated the highest VRC of all evaluated TAC techniques. Different levels of subatmospheric pressures applied to the VAC did not affect VRC. The results for ZS and VAC indicate that these TAC techniques may increase the risk for recurrent intra-abdominal hypertension and should therefore not be used in high-risk patients during the initial phase after abdominal decompression.

  9. Management of hidradenitis suppurativa wounds with an internal vacuum-assisted closure device.

    PubMed

    Chen, Y Erin; Gerstle, Theodore; Verma, Kapil; Treiser, Matthew D; Kimball, Alexandra B; Orgill, Dennis P

    2014-03-01

    Hidradenitis suppurativa is a chronic, debilitating disease that is difficult to treat. Once medical management fails, wide local excision offers the best chance for cure. However, the resultant wound often proves too large or contaminated for immediate closure. The authors performed a retrospective chart review of hidradenitis cases managed surgically between 2005 and 2010. Data collected included patient characteristics, management method, and outcomes. Approximately half of the patients received internal vacuum-assisted closure therapy using the vacuum-assisted closure system and delayed closure and half of the patients received immediate primary closure at the time of their excision. Delayed closure consisted of closing the majority of the wound in a linear fashion following internal vacuum-assisted closure while accepting healing by means of secondary intention for small wound areas. Patients managed with internal vacuum-assisted closure had wounds on average four times larger in area than patients managed without internal vacuum-assisted closure. In both groups, all wounds were eventually closed primarily. Healing times averaged 2.2 months with internal vacuum-assisted closure and 2.7 months without. At an average follow-up time of 2.3 months, all patients with internal vacuum-assisted closure had no recurrence of their local disease. Severe hidradenitis presents a treatment challenge, as surgical excisions are often complicated by difficult closures and unsatisfactory recurrence rates. This study demonstrates that wide local excision with reasonable outcomes can be achieved using accelerated delayed primary closure. This method uses internal vacuum-assisted closure as a bridge between excision and delayed primary closure, facilitating closure without recurrence in large, heavily contaminated wounds. Therapeutic, III.

  10. Sutureless circumcision using 2-Octyl cyanoacrylate results in more rapid and less painful procedures with excellent cosmetic satisfaction.

    PubMed

    Van Haute, C; Tailly, T; Klockaerts, K; Ringoir, Y

    2015-06-01

    Circumcision is the most common surgical procedure in male children in the world and is performed because of cultural, religious or medical reasons. Traditionally, interrupted sutures are used to close the wound, but 2-Octyl cyanoacrylate (2-OCA) tissue glue can be used as an alternative method to close the circumcision wound. To compare the use of 2-OCA with absorbable sutures in circumcision wound closure in prepubescent patients in terms of operative time, complication rate, postoperative pain and cosmetic results. We retrospectively evaluated 662 circumcision procedures using sutures and 609 procedures using 2-OCA for wound closure in prepubescent boys. All circumcision procedures were performed by 2 surgeons in a single centre. Operative time was collected from the hospital surgical software system. 62% of the patients in the suture group and 59% of the patients in the 2-OCA group presented for a postoperative check-up 6 weeks after the circumcision. Data regarding postoperative pain, need for analgesia, cosmetic satisfaction and the ease of wound care were collected through questionnaires completed by 25% of the boy's parents in the suture group and 53% of the parents in the 2-OCA group. Mean operative time was significantly shorter in the 2-OCA group (13 min) than in the suture group (17 min). Complications were comparable and mostly minor. Reintervention was only required in 3 cases. According to the parents, the degree of postoperative pain and the postoperative need for analgesics was significantly lower in the 2-OCA group. Wounds closed with 2-OCA were easier to care for. The cosmetic results after 1 day, after 1 week and after 1 month in the 2-OCA group were significantly superior than in the suture group, according to the parents' evaluation. The use of 2-OCA in circumcision wound closure has been reported before. Previous studies with mainly limited patient numbers report less pain, shorter procedure times and a higher surgeon satisfaction in terms of cosmetic results. This study is the largest study comparing the use of 2-OCA and interrupted sutures in circumcision wound closure. The retrospective character of the study, the lack of a validated questionnaire tool for the cosmetic evaluation and the use of the parent's evaluation are the limitations of this study. The use of 2-OCA in circumcision wound closure results in a shorter operative time, in less postoperative pain, in easy postoperative wound care and in excellent cosmesis when compared to interrupted absorbable sutures. 2-OCA is our current technique of choice in circumcision wound closure. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  11. Early decision-analytic modeling - a case study on vascular closure devices.

    PubMed

    Brandes, Alina; Sinner, Moritz F; Kääb, Stefan; Rogowski, Wolf H

    2015-10-27

    As economic considerations become more important in healthcare reimbursement, decisions about the further development of medical innovations need to take into account not only medical need and potential clinical effectiveness, but also cost-effectiveness. Already early in the innovation process economic evaluations can support decisions on development in specific indications or patient groups by anticipating future reimbursement and implementation decisions. One potential concept for early assessment is value-based pricing. The objective is to assess the feasibility of value-based pricing and product design for a hypothetical vascular closure device in the pre-clinical stage which aims at decreasing bleeding events. A deterministic decision-analytic model was developed to estimate the cost-effectiveness of established vascular closure devices from the perspective of the Statutory Health Insurance system. To identify early benchmarks for pricing and product design, three strategies of determining the product's value are explored: 1) savings from complications avoided by the new device; 2) valuation of the avoided complications based on an assumed willingness-to-pay-threshold (the efficiency frontier approach); 3) value associated with modifying the care pathways within which the device would be applied. Use of established vascular closure devices is dominated by manual compression. The hypothetical vascular closure device reduces overall complication rates at higher costs than manual compression. Maximum cost savings of only about €4 per catheterization could be realized by applying the hypothetical device. Extrapolation of an efficiency frontier is only possible for one subgroup where vascular closure devices are not a dominated strategy. Modifying care in terms of same-day discharge of patients treated with vascular closure devices could result in cost savings of €400-600 per catheterization. It was partially feasible to calculate value-based prices for the novel closure device which can be used to inform product design. However, modifying the care pathway may generate much more value from the payers' perspective than modifying the device per se. Manufacturers should thus explore the feasibility of combining reimbursement of their product with arrangements that make same-day discharge attractive also for hospitals. Due to the early nature of the product, the results are afflicted with substantial uncertainty.

  12. Storm related closures of I-5 and I-90 : freight transportation economic impact assessment report, winter 2007-2008.

    DOT National Transportation Integrated Search

    2008-09-01

    This report documents the economic impact analysis undertaken by WSDOTs Freight Systems Division in response to the : storm-related closures of I-5 and I-90 in the winter 2007-2008. The closures were the result of severe weather that : overwhelmed...

  13. 36 CFR 13.1120 - Bartlett Cove Developed Area closures and restrictions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... closures and restrictions. 13.1120 Section 13.1120 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and Preserve Bartlett Cove § 13.1120 Bartlett Cove Developed Area closures and restrictions...

  14. 36 CFR 13.1120 - Bartlett Cove Developed Area closures and restrictions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... closures and restrictions. 13.1120 Section 13.1120 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and Preserve Bartlett Cove § 13.1120 Bartlett Cove Developed Area closures and restrictions...

  15. 36 CFR 13.1120 - Bartlett Cove Developed Area closures and restrictions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... closures and restrictions. 13.1120 Section 13.1120 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and Preserve Bartlett Cove § 13.1120 Bartlett Cove Developed Area closures and restrictions...

  16. CORRRECTIVE ACTION DECISION DOCUMENT FOR CORRECTIVE ACTION UNIT 427: AREA 3 SEPTIC WASTE SYSTEMS 2 AND 6, TONOPAH TEST RANGE, NEVADA, REVISION 0, JUNE 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ITLV.

    1998-06-01

    This Corrective Action Decision Document has been prepared for the Area 3 Septic Waste Systems 2 and 6 (Corrective Action Unit 427) in accordance with the Federal Facility Agreement and Consent Order of 1996 (FFACO, 1996). Corrective Action Unit 427 is located at the Tonopah Test Range, Nevada, and is comprised of the following Corrective Action Sites, each an individual septic waste system (DOE/NV, 1996a): Septic Waste System 2 is Corrective Action Site Number 03-05-002-SW02. Septic Waste System 6 is Corrective Action Site Number 03-05-002-SW06. The purpose of this Corrective Action Decision Document is to identify and provide a rationalemore » for the selection of a recommended corrective action alternative for each Corrective Action Site. The scope of this Correction Action Decision Document consists of the following tasks: Develop corrective action objectives. Identify corrective action alternative screening criteria. Develop corrective action alternatives. Perform detailed and comparative evaluations of the corrective action alternatives in relation to the corrective action objectives and screening criteria. Recommend and justify a preferred corrective action alternative for each CAS. From November 1997 through January 1998, a corrective action investigation was performed as set forth in the Corrective Action Investigation Plan for Corrective Action Unit No. 427: Area 3 Septic Waste System Numbers 2 and 6, Tonopah Test Range, Nevada (DOE/NV, 1997b). Details can be found in Appendix A of this document. The results indicated that contamination is present in some portions of the CAU and not in others as described in Table ES-1 and shown in Figure A.2-2 of Appendix A. Based on the potential exposure pathways, the following corrective action objectives have been identified for Corrective Action Unit 427: Prevent or mitigate human exposure to subsurface soils containing TPH at concentrations greater than 100 milligrams per kilogram (NAC, 1996b). Close Septic Tank 33-5 in accordance with Nevada Administrative Code 459 (NAC, 1996c). Prevent adverse impacts to groundwater quality. Based on the review of existing data, future land use, and current operations at the Tonopah Test Range, the following alternatives were developed for consideration at the Area 3 Septic Waste Systems 2 and 6: Alternative 1 - No Further Action Alternative 2 - Closure of Septic Tank 33-5 and Administrative Controls Alternative 3 - Closure of Septic Tank 33-5, Excavation, and Disposal The corrective action alternatives were evaluated based on four general corrective action standards and five remedy selection decision factors. Based on the results of this evaluation, the preferred alternative for Corrective Action Unit 427 is Alternative 2, Closure of Septic Tank 33-5 and Administrative Controls. The preferred corrective action alternative was evaluated on technical merit, focusing on performance, reliability, feasibility, and safety. The alternative was judged to meet all requirements for the technical components evaluated. The alternative meets all applicable state and federal regulations for closure of the site and will reduce potential future exposure pathways to the contaminated soils. During corrective action implementation, this alternative will present minimal potential threat to site workers who come in contact with the waste. However, procedures will be developed and implemented to ensure worker health and safety.« less

  17. Skin closure using staples and nylon sutures: a comparison of results.

    PubMed Central

    Stockley, I.; Elson, R. A.

    1987-01-01

    A disposable skin stapler (Elite: Auto Suture UK Ltd) and Nylon vertical mattress sutures have been used for skin closure. The complications related to each method were evaluated in 129 wounds. There was a higher incidence of inflammation, discomfort on removal and spreading of the healing scar associated with staples. The only advantage of staples was speed of wound closure. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:3566131

  18. Steady state conductance in a double quantum dot array: the nonequilibrium equation-of-motion Green function approach.

    PubMed

    Levy, Tal J; Rabani, Eran

    2013-04-28

    We study steady state transport through a double quantum dot array using the equation-of-motion approach to the nonequilibrium Green functions formalism. This popular technique relies on uncontrolled approximations to obtain a closure for a hierarchy of equations; however, its accuracy is questioned. We focus on 4 different closures, 2 of which were previously proposed in the context of the single quantum dot system (Anderson impurity model) and were extended to the double quantum dot array, and develop 2 new closures. Results for the differential conductance are compared to those attained by a master equation approach known to be accurate for weak system-leads couplings and high temperatures. While all 4 closures provide an accurate description of the Coulomb blockade and other transport properties in the single quantum dot case, they differ in the case of the double quantum dot array, where only one of the developed closures provides satisfactory results. This is rationalized by comparing the poles of the Green functions to the exact many-particle energy differences for the isolate system. Our analysis provides means to extend the equation-of-motion technique to more elaborate models of large bridge systems with strong electronic interactions.

  19. Automated method for determining Instron Residual Seal Force of glass vial/rubber closure systems.

    PubMed

    Ludwig, J D; Nolan, P D; Davis, C W

    1993-01-01

    Instron Residual Seal Force (IRSF) of glass vial/rubber closure systems was determined using an Instron 4501 Materials Testing System. Computer programs were written to process raw data and calculate IRSF values. Preliminary experiments indicated both the appearance of the stress-deformation curves and precision of the derived IRSF values were dependent on the internal dimensions and top surface geometry of the cap anvil. Therefore, a series of five cap anvils varying in shape and dimensions were machined to optimize performance and precision. Vials capped with West 4416/50 PURCOAT button closures or Helvoet compound 6207 lyophilization closures were tested with each cap anvil. Cap anvils with spherical top surfaces and narrow internal dimensions produced more precise results and more uniform stress-deformation curves than cap anvils with flat top surfaces and wider internal dimensions.

  20. 10 CFR 960.5-1 - System guidelines.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REPOSITORY Preclosure Guidelines § 960.5-1 System guidelines. (a) Qualifying conditions—(1) Preclosure... radioactive materials to restricted and unrestricted areas during repository operation and closure shall meet... repository siting, construction, operation, closure, and decommissioning the public and the environment shall...

  1. Laceration of the Common Femoral Artery Following Deployment of the StarClose{sup TM} Vascular Closure System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonsalves, Michael, E-mail: drmag1975@gmail.com; Walkden, Miles, E-mail: rwalkden@nhs.net; Belli, Anna Maria, E-mail: Anna.Belli@stgeorges.nhs.u

    2008-07-15

    StarClose is a novel arterial closure device which achieves hemostasis, following arteriotomy, via a nitinol clip deployed on the outer arterial wall. Since its introduction to the market, several studies have shown StarClose to be both safe and effective, with few major complications encountered. We report a case of common femoral artery laceration following deployment of the StarClose vascular closure system. We conclude that the injury occurred secondary to intravascular misplacement of the nitinol clip.

  2. Simulating school closure policies for cost effective pandemic decision making

    PubMed Central

    2012-01-01

    Background Around the globe, school closures were used sporadically to mitigate the 2009 H1N1 influenza pandemic. However, such closures can detrimentally impact economic and social life. Methods Here, we couple a decision analytic approach with a mathematical model of influenza transmission to estimate the impact of school closures in terms of epidemiological and cost effectiveness. Our method assumes that the transmissibility and the severity of the disease are uncertain, and evaluates several closure and reopening strategies that cover a range of thresholds in school-aged prevalence (SAP) and closure durations. Results Assuming a willingness to pay per quality adjusted life-year (QALY) threshold equal to the US per capita GDP ($46,000), we found that the cost effectiveness of these strategies is highly dependent on the severity and on a willingness to pay per QALY. For severe pandemics, the preferred strategy couples the earliest closure trigger (0.5% SAP) with the longest duration closure (24 weeks) considered. For milder pandemics, the preferred strategies also involve the earliest closure trigger, but are shorter duration (12 weeks for low transmission rates and variable length for high transmission rates). Conclusions These findings highlight the importance of obtaining early estimates of pandemic severity and provide guidance to public health decision-makers for effectively tailoring school closures strategies in response to a newly emergent influenza pandemic. PMID:22713694

  3. Cost-Effectiveness of Percutaneous Closure of the Left Atrial Appendage in Atrial Fibrillation Based on Results From PROTECT AF Versus PREVAIL.

    PubMed

    Freeman, James V; Hutton, David W; Barnes, Geoffrey D; Zhu, Ruo P; Owens, Douglas K; Garber, Alan M; Go, Alan S; Hlatky, Mark A; Heidenreich, Paul A; Wang, Paul J; Al-Ahmad, Amin; Turakhia, Mintu P

    2016-06-01

    Randomized trials of left atrial appendage (LAA) closure with the Watchman device have shown varying results, and its cost effectiveness compared with anticoagulation has not been evaluated using all available contemporary trial data. We used a Markov decision model to estimate lifetime quality-adjusted survival, costs, and cost effectiveness of LAA closure with Watchman, compared directly with warfarin and indirectly with dabigatran, using data from the long-term (mean 3.8 year) follow-up of Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation (PROTECT AF) and Prospective Randomized Evaluation of the Watchman LAA Closure Device in Patients With Atrial Fibrillation (PREVAIL) randomized trials. Using data from PROTECT AF, the incremental cost-effectiveness ratios compared with warfarin and dabigatran were $20 486 and $23 422 per quality-adjusted life year, respectively. Using data from PREVAIL, LAA closure was dominated by warfarin and dabigatran, meaning that it was less effective (8.44, 8.54, and 8.59 quality-adjusted life years, respectively) and more costly. At a willingness-to-pay threshold of $50 000 per quality-adjusted life year, LAA closure was cost effective 90% and 9% of the time under PROTECT AF and PREVAIL assumptions, respectively. These results were sensitive to the rates of ischemic stroke and intracranial hemorrhage for LAA closure and medical anticoagulation. Using data from the PROTECT AF trial, LAA closure with the Watchman device was cost effective; using PREVAIL trial data, Watchman was more costly and less effective than warfarin and dabigatran. PROTECT AF enrolled more patients and has substantially longer follow-up time, allowing greater statistical certainty with the cost-effectiveness results. However, longer-term trial results and postmarketing surveillance of major adverse events will be vital to determining the value of the Watchman in clinical practice. © 2016 American Heart Association, Inc.

  4. Effectiveness of viable cryopreserved placental membranes for management of diabetic foot ulcers in a real world setting.

    PubMed

    Raspovic, Katherine M; Wukich, Dane K; Naiman, Daniel Q; Lavery, Lawrence A; Kirsner, Robert S; Kim, Paul J; Steinberg, John S; Attinger, Christopher E; Danilkovitch, Alla

    2018-04-23

    In a multicenter randomized controlled trial (RCT), the use of viable cryopreserved placental membrane (vCPM) for chronic diabetic foot ulcers (DFUs) resulted in a higher proportion of wound closure in comparison to good wound care: 62% vs. 21% (p < 0.01). However, patients in RCTs are not representative of daily physician practice. Healthcare databases serve as a valuable tool to evaluate therapy effectiveness and to supplement evidence from RCTs. The objective of this study was to evaluate the effectiveness of vCPM for DFU management using Net Health's WoundExpert ® electronic health records (EHR). The primary endpoint was the proportion of DFUs that achieved complete closure. Other endpoints included time and number of grafts to closure, probability of wound closure by week 12, and the number of wound-related infections and amputations. De-identified EHR data for 360 patients with 441 wounds treated with vCPM were extracted from the database. Average patient age was 63.7 years with a mean wound size of 5.1 cm 2 and an average wound duration of 102 days prior to vCPM treatment. For evaluation of clinical outcomes, 350 DFUs larger than 0.25 cm 2 at baseline were analyzed. Closure at the end of treatment was achieved in 59.4% of wounds with a median treatment duration of 42.0 days and 4 applications of vCPM. The probability of wound closure at week 12 was 71%, and the number of amputations and wound-related infections was 13 (3.0%) and 9 (2.0%), respectively. Data also demonstrated a correlation between wound size and closure rate as well as a correlation between > 50% wound area reduction by week 4 and wound closure by week 12. The results of this study mirror previous RCT efficacy data, supporting the benefits of vCPM for DFU management. These results can also influence policy and treatment decisions regarding advanced vCPM technology. This article is protected by copyright. All rights reserved. © 2018 by the Wound Healing Society.

  5. Re-design and fabrication of titanium multi-wall Thermal Protection System (TPS) test panels

    NASA Technical Reports Server (NTRS)

    Blair, W.; Meaney, J. E., Jr.; Rosenthal, H. A.

    1984-01-01

    The Titanium Multi-wall Thermal Protection System (TIPS) panel was re-designed to incorporate Ti-6-2-4-2 outer sheets for the hot surface, ninety degree side closures for ease of construction and through panel fastness for ease of panel removal. Thermal and structural tests were performed to verify the design. Twenty-five panels were fabricated and delivered to NASA for evaluation at Langley Research Center and Johnson Space Center.

  6. Parabolic dish test site: History and operating experience

    NASA Technical Reports Server (NTRS)

    Selcuk, M. K. (Compiler)

    1985-01-01

    The parabolic dish test site (PDTS) was established for testing point-focusing solar concentrator systems operating at temperatures approaching 1650 C. Among tests run were evaluation and performance characterization of parabolic dish concentrators, receivers, power conversion units, and solar/fossil-fuel hybrid systems. The PDTS was fully operational until its closure in June, 1984. The evolution of the test program, a chronological listing of the experiments run, and data summaries for most of the tests conducted are presented.

  7. Closure Report for Corrective Action Unit 516: Septic Systems and Discharge Points

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    Corrective Action Unit (CAU) 516 is located in Areas 3, 6, and 22 of the Nevada Test Site. CAU 516 is listed in the Federal Facility Agreement and Consent Order of 1996 as Septic Systems and Discharge Points, and is comprised of six Corrective Action Sites (CASs): {sm_bullet} CAS 03-59-01, Bldg 3C-36 Septic System {sm_bullet} CAS 03-59-02, Bldg 3C-45 Septic System {sm_bullet} CAS 06-51-01, Sump and Piping {sm_bullet} CAS 06-51-02, Clay Pipe and Debris {sm_bullet} CAS 06-51-03, Clean Out Box and Piping {sm_bullet} CAS 22-19-04, Vehicle Decontamination Area The Nevada Division of Environmental Protection (NDEP)-approved corrective action alternative for CASsmore » 06-51-02 and 22-19-04 is no further action. The NDEP-approved corrective action alternative for CASs 03-59-01, 03-59-02, 06-51-01, and 06-51-03 is clean closure. Closure activities included removing and disposing of total petroleum hydrocarbon (TPH)-impacted septic tank contents, septic tanks, distribution/clean out boxes, and piping. CAU 516 was closed in accordance with the NDEP-approved CAU 516 Corrective Action Plan (CAP). The closure activities specified in the CAP were based on the recommendations presented in the CAU 516 Corrective Action Decision Document (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2004). This Closure Report documents CAU 516 closure activities. During closure activities, approximately 186 tons of hydrocarbon waste in the form of TPH-impacted soil and debris, as well as 89 tons of construction debris, were generated and managed and disposed of appropriately. Waste minimization techniques, such as field screening of soil samples and the utilization of laboratory analysis to characterize and classify waste streams, were employed during the performance of closure work.« less

  8. Economic comparison of methods of wound closure: wound closure strips vs. sutures and wound adhesives.

    PubMed

    Zempsky, William T; Zehrer, Cindy L; Lyle, Christopher T; Hedbloom, Edwin C

    2005-09-01

    Our objective was to review and assess the treatment of low-tension wounds and evaluate the cost-effectiveness of wound closure methods. We used a health economic model to estimate cost/closure of adhesive wound closure strips, tissue adhesives and sutures. The model incorporated cost-driving variables: application time, costs and the likelihood and costs of dehiscence and infection. The model was populated with variable estimates derived from the literature. Cost estimates and cosmetic results were compared. Parameter values were estimated using national healthcare and labour statistics. Sensitivity analyses were used to verify the results. Our analysis suggests that adhesive wound closure strips had the lowest average cost per laceration ($7.54), the lowest cost per infected laceration ($53.40) and the lowest cost per laceration with dehiscence ($25.40). The costs for sutures were $24.11, $69.91 and $41.91, respectively; the costs for tissue adhesives were $28.77, $74.68 and $46.68, respectively. The cosmetic outcome for all three treatments was equivalent. We conclude adhesive wound closure strips were both a cost-saving and a cost-effective alternative to sutures and tissue adhesives in the closure of low-tension lacerations.

  9. 46 CFR 64.41 - Stop valve closure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Stop valve closure. 64.41 Section 64.41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Standards for an MPT § 64.41 Stop valve closure. A stop valve that operates by a screwed...

  10. Mechanics of Wound Closure: Emerging Tape-Based Wound Closure Technology vs. Traditional Methods.

    PubMed

    Levi, Kemal; Ichiryu, Kei; Kefel, Pelin; Keller, Juergen; Grice, Jon; Belson, Ori; Storne, Eric; Safa, Bauback

    2016-10-12

    To date, there is still a lack of understanding of how wound closure methods perform comparatively under daily bodily movement during the course of healing and how they affect the mechanics of healing. The present study is a first step in understanding and objectively quantifying the gap. The study provides both a new method of metrology for noninvasive evaluation of skin mechanics at the onset of wound healing and an emerging tape-based wound closure technology. The latter shows better performance with respect to commonly used staples and sutures, holding the wound intact and providing uniform mechanical support across the incision.

  11. Tissue loads applied by a novel medical device for closing large wounds.

    PubMed

    Katzengold, Rona; Topaz, Moris; Gefen, Amit

    2016-02-01

    Closure of large soft tissue defects following surgery or trauma as well as closure of large chronic wounds constitutes substantial but common reconstructive challenges. In such cases, an attempt to use conventional suturing will result in high-tension closure, therefore alternative external skin stretching systems were developed. These types of devices were meant to reduce local mechanical loads in the skin and the underlying tissues, taking advantage of the viscoelastic properties of the skin, especially mechanical creep, for primary wound closure. Studies have shown the clinical advantages of skin stretching systems, however, quantitative bioengineering models, demonstrating closure of large wounds, are lacking. Here we present finite element (FE) modeling of the TopClosure(®) tension relief system (TRS) and its biomechanical efficacy in three (real) wound cases, compared with the alternative of a conventional surgical suturing closure technique. Our simulations showed that peak effective stresses on the skin were at least an order of magnitude greater (and sometimes nearly 2 orders-of-magnitude greater) when tension sutures were used with respect to the corresponding TRS data. For the tension suture simulations, the tensile stress was in the range of 415-648 MPa and in the TRS simulations, it was 16-30 MPa. Based on the present computational FE modeling, the TRS reduces localized tissue deformations and stress concentrations in skin and underlying tissues while closing large wounds, compared to the deformations and stresses that are inflicted during the process of suturing. This substantial reduction of loads allows surgeons to better employ the viscoelastic properties of the skin for primary wound closure. Copyright © 2015 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  12. Long-term outcome in dogs with patent ductus arteriosus: 520 cases (1994-2009).

    PubMed

    Saunders, A B; Gordon, S G; Boggess, M M; Miller, M W

    2014-01-01

    Published information regarding survival and long-term cardiac remodeling after patent ductus arteriosus (PDA) closure in dogs is limited. To report outcome and identify prognostic variables in dogs with PDA, and to identify risk factors for persistent remodeling in dogs with a minimum of 12 months of follow-up after closure. Five hundred and twenty client-owned dogs. Retrospective review of medical records of 520 dogs with PDA. Outcome was determined by contacting owners and veterinarians. Dogs with PDA closure and ≥ 12 months of follow-up were asked to return for a re-evaluation. In multivariable analysis of 506 dogs not euthanized at the time of diagnosis, not having a PDA closure procedure negatively affected survival (HzR = 16.9, P < .001). In 444 dogs undergoing successful PDA closure, clinical signs at presentation (HzR = 17, P = .02), concurrent congenital heart disease (HD) (HzR = 4.8, P = .038), and severe mitral regurgitation (MR) documented within 24 hours of closure (HzR = 4.5, P = .028) negatively affected survival. Seventy-one dogs with ≥ 12 months follow-up demonstrated a significant reduction in radiographic and echocardiographic measures of heart size (P = 0) and increased incidence of acquired HD (P = .001) at re-evaluation. Dogs with increased left ventricular size and low fractional shortening at baseline were more likely to have persistent remodeling at re-evaluation. Patent ductus arteriosus closure confers important survival benefits and results in long-term reverse remodeling in most dogs. Clinical signs at presentation, concurrent congenital HD, and severe MR negatively affect survival. Increased left ventricular systolic dimensions and systolic dysfunction at baseline correlated significantly with persistent remodeling. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  13. 40 CFR 265.228 - Closure and post-closure care.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... detection system in accordance with §§ 264.221(c)(2)(iv) and (3) of this chapter and 265.226(b) and comply with all other applicable leak detection system requirements of this part; (3) Maintain and monitor the... or operator must: (1) Remove or decontaminate all waste residues, contaminated containment system...

  14. Corrective Action Decision Document/Closure Report for Corrective Action Unit 567: Miscellaneous Soil Sites - Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, Patrick

    2014-12-01

    This Corrective Action Decision Document/Closure Report presents information supporting the closure of Corrective Action Unit (CAU) 567: Miscellaneous Soil Sites, Nevada National Security Site, Nevada. The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation that no further corrective action is needed for CAU 567 based on the implementation of the corrective actions. The corrective actions implemented at CAU 567 were developed based on an evaluation of analytical data from the CAI, the assumed presence of COCs at specific locations, and the detailed and comparative analysis of the CAAs. The CAAs weremore » selected on technical merit focusing on performance, reliability, feasibility, safety, and cost. The implemented corrective actions meet all requirements for the technical components evaluated. The CAAs meet all applicable federal and state regulations for closure of the site. Based on the implementation of these corrective actions, the DOE, National Nuclear Security Administration Nevada Field Office provides the following recommendations: • No further corrective actions are necessary for CAU 567. • The Nevada Division of Environmental Protection issue a Notice of Completion to the DOE, National Nuclear Security Administration Nevada Field Office for closure of CAU 567. • CAU 567 be moved from Appendix III to Appendix IV of the FFACO.« less

  15. Hypertrophied tonsils impair velopharyngeal function after palatoplasty.

    PubMed

    Abdel-Aziz, Mosaad

    2012-03-01

    When tonsillar hypertrophy obstructing the airway is encountered in a child with a repaired cleft palate and velopharyngeal insufficiency, the surgeon may opt for tonsillectomy to relieve the airway obstruction, with possible effects on velopharyngeal closure. The aim of this study was to assess the impact of hypertrophied tonsils on velopharyngeal function in children with repaired cleft palate and to measure the effect of tonsillectomy on velopharyngeal closure and speech resonance. Case series. Twelve children with repaired cleft palate and tonsillar hypertrophy underwent tonsillectomy to relieve airway obstruction. Preoperative and postoperative evaluation of velopharyngeal function was performed. Auditory perceptual assessment of speech and nasalance scores were measured, and velopharyngeal closure was evaluated by flexible nasopharyngoscopy. Preoperative impairment of velopharyngeal function was detected. However, significant postoperative improvement of speech parameters (hypernasality, nasal emission of air, and weak pressure consonants measured with auditory perceptual assessment) was achieved, and the overall postoperative nasalance score was improved significantly for nasal and oral sentences. Reduction of velopharyngeal gap size was detected after removal of hypertrophied tonsils. Although the improvement of velopharyngeal closure was not significant, three cases demonstrated complete postoperative closure with no gap. Hypertrophied tonsils may impair velopharyngeal function in children with repaired cleft palate, and tonsillectomy is beneficial for such patients as it can improve the velopharyngeal closure and speech resonance. Secondary corrective surgery may be avoided in some cases after tonsillectomy. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  16. Primary closure versus delayed closure for non bite traumatic wounds within 24 hours post injury.

    PubMed

    Eliya-Masamba, Martha C; Banda, Grace W

    2013-10-22

    Acute traumatic wounds are one of the common reasons why people present to the emergency department. Primary closure has traditionally been reserved for traumatic wounds presenting within six hours of injury and considered 'clean' by the attending surgeon, with the rest undergoing delayed primary closure as a means of controlling wound infection. Primary closure has the potential benefit of rapid wound healing but poses the potential threat of increased wound infection. There is currently no evidence to guide clinical decision-making on the best timing for closure of traumatic wounds. To determine the effect on time to healing of primary closure versus delayed closure for non bite traumatic wounds presenting within 24 hours post injury. To explore the adverse effects of primary closure compared with delayed closure for non bite traumatic wounds presenting within 24 hours post injury. In May 2013, for this first update we searched the Cochrane Wounds Group Specialised Register; the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. There were no restrictions with respect to language, date of publication or study setting. Randomised controlled trials comparing primary closure with delayed closure of non bite traumatic wounds. Two review authors independently evaluated the results of the searches against the inclusion criteria. No studies met the inclusion criteria for this review. Since no studies met the inclusion criteria, neither a meta-analysis nor a narrative description of studies was possible. There is currently no systematic evidence to guide clinical decision-making regarding the timing for closure of traumatic wounds. There is a need for robust research to investigate the effect of primary closure compared with delayed closure for non bite traumatic wounds presenting within 24 hours of injury.

  17. Clinical evaluation of neodymium-iron-boron (Ne2Fe14B) rare earth magnets in the treatment of mid line diastemas

    PubMed Central

    Manoj-Kumar, Mitta; Gowri-Sankar, Singaraju; Chaitanya, Nellore; Vivek-Reddy, Ganugapanta; Venkatesh, Nettam

    2016-01-01

    Background To evaluate the closure of midline diastema using the Neodymium-Iron-Boron magnets and to compare the treatment duration of midline diastemas with the use of magnets compared to regular orthodontic treatment. Material and Methods Thirty patients with age group 12 to 30 years with the midline diastema ranging from 0.5 to 3mm were selected. These patients were divided into two groups. Diastema closure in one group was accomplished by conventional method, in other group was done with Ne2Fe14B magnets. These magnets were fitted to the labial surfaces of the maxillary central incisors such a way that the opposite poles of the magnets face each other. At each appointment, study models and radiographs were taken for study subjects and the midline diastema was measured using digital vernier calipers on the study models obtained. Descriptive statistics carried out using Paired t-test. Results Subjects treated with Ne2Fe14B magnets showed a significant difference compared to fixed orthodontic appliance subjects with respect to time of closure, rate of space closure and incisal inclination. Significant difference between 2 groups with reduction of 64.6 days in time to diastema closure in subjects treated with Ne2Fe14B magnets (P<0.05). Conclusions Ne2Fe14B magnets more efficient in complete closure of mid line diastema in less duration of time. Key words:Midline diastema, Ne2Fe14B magnets, rare earth magnets, space closure. PMID:27034757

  18. Preliminary experience with a new device for delayed sternal closure strategy in cardiac surgery.

    PubMed

    Santini, Francesco; Onorati, Francesco; Telesca, Mariassunta; Faggian, Giuseppe; Mazzucco, Alessandro

    2012-06-01

    Open chest management with delayed sternal closure (DSC) is a valuable strategy in the management of patients with postcardiotomy hemodynamic instability or severe coagulopathy. The conventional extemporized material available for off-label sternal stenting however may limit its efficacy. We evaluated outcomes of patients with refractory severe postcardiotomy cardiogenic shock (SPCCS) treated with DSC using a novel temporary sternal spreader (NTSS) which allows myocardial recovery by progressive controlled approximation of the sternal edges. Seven patients (4 male, mean age 66.5 ± 5 years) with refractory SPCCS showing acute hemodynamic instability at sternal closure, were implanted with the NTSS, consisting of stainless-steel branches linked to 2 diverging plates of polyether-ether ketone, whose progressive opening/closing mechanism can be controlled from outside the chest with a rotating steel wire. The sternal wound was closed by an elastic membrane to achieve a sterile field. Swan-Ganz monitoring was employed, and clinical outcomes evaluated. The device was successfully implanted in all patients without device-related complications or failures. Progressive approximation of sternal edges, titrated on cardiac index values, was successfully completed allowing subsequent uneventful sternal closure in all. Mean time from SPCCS to sternal closure was 70 ± 21 hours. No patient developed infective complications or late hemodynamic instability after device removal and sternal closure. One patient (14%) died of multiorgan failure on postoperative day 9. Despite the limited number of patients enrolled, the NTSS proved safe and effective in allowing complete myocardial recovery after SPCCS, avoiding hemodynamic instability related to abrupt sternal closure, with no occurrence of infective complications.

  19. Don't Trust a Management Metric, Especially in Life Support

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2014-01-01

    Goodhart's law states that metrics do not work. Metrics become distorted when used and they deflect effort away from more important goals. These well-known and unavoidable problems occurred when the closure and system mass metrics were used to manage life support research. The intent of life support research should be to develop flyable, operable, reliable systems, not merely to increase life support system closure or to reduce its total mass. It would be better to design life support systems to meet the anticipated mission requirements and user needs. Substituting the metrics of closure and total mass for these goals seems to have led life support research to solve the wrong problems.

  20. Axiomatic Design of Space Life Support Systems

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2017-01-01

    Systems engineering is an organized way to design and develop systems, but the initial system design concepts are usually seen as the products of unexplained but highly creative intuition. Axiomatic design is a mathematical approach to produce and compare system architectures. The two axioms are:- Maintain the independence of the functional requirements.- Minimize the information content (or complexity) of the design. The first axiom generates good system design structures and the second axiom ranks them. The closed system human life support architecture now implemented in the International Space Station has been essentially unchanged for fifty years. In contrast, brief missions such as Apollo and Shuttle have used open loop life support. As mission length increases, greater system closure and increased recycling become more cost-effective.Closure can be gradually increased, first recycling humidity condensate, then hygiene wastewater, urine, carbon dioxide, and water recovery brine. A long term space station or planetary base could implement nearly full closure, including food production. Dynamic systems theory supports the axioms by showing that fewer requirements, fewer subsystems, and fewer interconnections all increase system stability. If systems are too complex and interconnected, reliability is reduced and operations and maintenance become more difficult. Using axiomatic design shows how the mission duration and other requirements determine the best life support system design including the degree of closure.

  1. Effectiveness of closure of public places with time delay in disease control.

    PubMed

    Wang, Zhenggang; Szeto, Kwok Yip; Leung, Frederick Chi-Ching

    2008-08-25

    A theoretical basis for the evaluation of the effciency of quarantine measure is developed in a SIR model with time delay. In this model, the effectiveness of the closure of public places such as schools in disease control, modeled as a high degree node in a social network, is evaluated by considering the effect of the time delay in the identification of the infected. In the context of the SIR model, the relation between the number of infectious individuals who are identified with time delay and then quarantined and those who are not identified and continue spreading the virus are investigated numerically. The social network for the simulation is modeled by a scale free network. Closure measures are applied to those infected nodes with high degrees. The effectiveness of the measure can be controlled by the present value of the critical degree K(C): only those nodes with degree higher than K(C) will be quarantined. The cost C(Q) incurred for the closure measure is assumed to be proportional to the total links rendered inactive as a result of the measure, and generally decreases with K(C), while the medical cost C(Q) incurred for virus spreading increases with K(C). The total social cost (C(M) + C(Q)) will have a minimum at a critical K(*), which depends on the ratio of medical cost coeffcient alpha(M) and closure cost coeffcient alpha(Q). Our simulation results demonstrate a mathematical procedure to evaluate the effciency of quarantine measure. Although the numerical work is based on a scale free network, the procedure can be readily generalized and applied to a more realistic social network to determine the proper closure measure in future epidemics.

  2. CLOSURE REPORT FOR CORRECTIVE ACTION UNIT165: AREA 25 AND 26 DRY WELL AND WASH DOWN AREAS, NEVADA TEST SITE, NEVADA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BECHTEL NEVADA

    This Closure Report (CR) documents the closure activities for Corrective Action Unit (CAU) 165, Area 25 and 26 Dry Well and Washdown Areas, according to the Federal Facility Agreement and Consent Order (FFACO) of 1996. CAU 165 consists of 8 Corrective Action Sites (CASs) located in Areas 25 and 26 of the Nevada Test Site (NTS). The NTS is located approximately 105 kilometers (65 miles) northwest of Las Vegas, nevada. Site closure activities were performed according to the Nevada Division of Environmental Protection (NDEP)-approved Corrective Action Plan (CAP) for CAU 165. CAU 165 consists of the following CASs: (1) CASmore » 25-07-06, Train Decontamination Area; (2) CAS 25-07-07, Vehicle Washdown; (3) CAS 25-20-01, Lab Drain Dry Well; (4) CAS 25-47-01, Reservoir and French Drain; (5) CAS 25-51-02, Drywell; (6) CAS 25-59-01, Septic System; (7) CAS 26-07-01, Vehicle Washdown Station; and (8) CAS 26-59-01, Septic System. CAU 165, Area 25 and 26 Dry Well and Washdown Areas, consists of eight CASs located in Areas 25 and 26 of the NTS. The approved closure alternatives included No Further Action, Clean Closure, and Closure in Place with Administrative Controls.« less

  3. Space life sciences: closed ecological systems: earth and space applications.

    PubMed

    2005-01-01

    This issue contains peer-reviewed papers from a workshop on Closed Ecological Systems: Earth and Space Applications at the 35th COSPAR General Assembly in Paris, France, convened in July 2004. The contributions reflected the wide range of international work in the field, especially Europe, Russia, Japan, and the United States. The papers are arranged according to four main themes: 1) Methods of evaluation and theory of closed ecological systems; 2) Reports from recent experiments in closed ecological system facilities; 3) Bioregenerative technologies to advance degree of closure and cycling; and 4) Laboratory studies of small closed ecological systems.

  4. Amnioserosa cell constriction but not epidermal actin cable tension autonomously drives dorsal closure.

    PubMed

    Pasakarnis, Laurynas; Frei, Erich; Caussinus, Emmanuel; Affolter, Markus; Brunner, Damian

    2016-11-01

    Tissue morphogenesis requires coordination of multiple force-producing components. During dorsal closure in fly embryogenesis, an epidermis opening closes. A tensioned epidermal actin/MyosinII cable, which surrounds the opening, produces a force that is thought to combine with another MyosinII force mediating apical constriction of the amnioserosa cells that fill the opening. A model proposing that each force could autonomously drive dorsal closure was recently challenged by a model in which the two forces combine in a ratchet mechanism. Acute force elimination via selective MyosinII depletion in one or the other tissue shows that the amnioserosa tissue autonomously drives dorsal closure while the actin/MyosinII cable cannot. These findings exclude both previous models, although a contribution of the ratchet mechanism at dorsal closure onset remains likely. This shifts the current view of dorsal closure being a combinatorial force-component system to a single tissue-driven closure event.

  5. Pericardium closure after heart operations: a safety option?

    PubMed

    Dantas, Carlos Eduardo Pereira; Sá, Mauro Paes Leme de; Bastos, Eduardo Sergio; Magnanini, Monica M F

    2010-01-01

    Primary pericardium closure may reduce the risk of cardiac injury during chest re opening, especially the right ventricle, aorta and coronary bypass grafts. Nevertheless, concern about adverse hemodynamic effects prevents most heart surgeons of closuring the pericardium. We evaluated 48 patients undergoing open heart surgery consecutively which the pericardium was closed in 30 patients (group A) and 18 patients, as a control group (group B) in which the pericardium was left open. All patients underwent posteroanterior and lateral chest roentgenograms before surgery and one week postoperatively. Postoperative evaluation also included echocardiograms, ECG and postoperative enzyme analysis. There were no deaths or any complications in both groups (acute myocardial infarction, stroke, bleeding or cardiac tamponate). It was observed statistically differences between both groups especially in echocardiogram parameters and cardiothoracic ratio without clinical impact. Pericardium closure is a simple method to facilitate resternotomy during subsequent re operative procedures. However, cardiac surgeons should be aware of the transient deterioration in hemodynamics associated with it, even thought there was no clinical significance in this study.

  6. Corrective Action Decision Document/Closure Report for Corrective Action Unit 274: Septic Systems, Nevada Test Site, Nevada, Rev. No.: 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grant Evenson

    2006-09-01

    This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit 274, Septic Systems, Nevada Test Site (NTS), Nevada in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit (CAU) 274 is comprised of five corrective action sites (CASs): (1) CAS 03-02-01, WX-6 ETS Building Septic System; (2) CAS 06-02-01, Cesspool; (3) CAS 09-01-01, Spill Site; (4) CAS 09-05-01, Leaching Pit; and (5) CAS 20-05-01, Septic System. The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the closure of CAU 274 with no further corrective action. Tomore » achieve this, corrective action investigation (CAI) activities were performed from November 14 through December 17, 2005 as set forth in the CAU 274 Corrective Action Investigation Plan. The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: (1) Determine whether contaminants of concern (COCs) are present. (2) If contaminants of concern are present, determine their nature and extent. (3) Provide sufficient information and data to complete appropriate corrective actions. The CAU 274 dataset from the investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the quality and acceptability of the dataset for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against final action levels (FALs) established in this document. No analytes were detected at concentrations exceeding the FALs. No COCs have been released to the soil at CAU 274, and corrective action is not required. Therefore, the DQO data needs were met, and it was determined that no corrective action based on risk to human receptors is necessary for the site. All FALs were calculated using the industrial site worker scenario except for benzo(a)pyrene, which was calculated based on the occasional use scenario. Benzo(a)pyrene was detected above the preliminary action level at CAS 20-05-01; however, it was not identified as a COC because the concentration was below the FAL. As a best management practice and to ensure that future site workers are not exposed to this site contaminant for more than this decision-basis exposure duration, an administrative use restriction was established around the leachfield at CAS 20-05-01. In addition, the removal of the septic tanks and septic tank contents at CASs 03-02-01, 06-02-01, and 20-05-01 was performed.« less

  7. Use of a counterfactual approach to evaluate the effect of area closures on fishing location in a tropical tuna fishery

    PubMed Central

    Davies, Tim K.; Mees, Chris C.; Milner-Gulland, E. J.

    2017-01-01

    Spatial closures are widely used in marine conservation and fisheries management and it is important to understand their contribution to achieving management objectives. Many previous evaluations of closed area effects have used before-after comparisons, which, without controlling for a full range of factors, cannot ascribe changes in fleet behaviour to area closures per se. In this study we used a counterfactual approach to disentangle the effect of two closed areas on fishing location from other competing effects on the behaviour of the Indian Ocean tuna purse seine fishery. Our results revealed an inconsistent effect of the one of the closed areas between years, after taking into account the influence of environmental conditions on fleet behaviour. This suggests that the policy of closing the area per se was not the main driver for the fleet allocating its effort elsewhere. We also showed a marked difference in effect between the two closed areas resulting from their different locations in the fishery area. These findings highlight the need to account for other key fleet behavioural drivers when predicting or evaluating the contribution of area closures to achieving conservation and fishery management objectives. PMID:28355269

  8. Use of a counterfactual approach to evaluate the effect of area closures on fishing location in a tropical tuna fishery.

    PubMed

    Davies, Tim K; Mees, Chris C; Milner-Gulland, E J

    2017-01-01

    Spatial closures are widely used in marine conservation and fisheries management and it is important to understand their contribution to achieving management objectives. Many previous evaluations of closed area effects have used before-after comparisons, which, without controlling for a full range of factors, cannot ascribe changes in fleet behaviour to area closures per se. In this study we used a counterfactual approach to disentangle the effect of two closed areas on fishing location from other competing effects on the behaviour of the Indian Ocean tuna purse seine fishery. Our results revealed an inconsistent effect of the one of the closed areas between years, after taking into account the influence of environmental conditions on fleet behaviour. This suggests that the policy of closing the area per se was not the main driver for the fleet allocating its effort elsewhere. We also showed a marked difference in effect between the two closed areas resulting from their different locations in the fishery area. These findings highlight the need to account for other key fleet behavioural drivers when predicting or evaluating the contribution of area closures to achieving conservation and fishery management objectives.

  9. Effectiveness of Recombinant Human Growth Hormone for Pharyngocutaneous Fistula Closure.

    PubMed

    Kucuk, Nurten; Sari, Murat; Midi, Ahmet; Yumusakhuylu, Ali Cemal; Findik, Ozan; Binnetoglu, Adem

    2015-12-01

    In laryngeal cancer, which comprises 25% of head and neck cancer, chemotherapy has come into prominence with the increase in organ-protective treatments. With such treatment, salvage surgery has increased following recurrence; the incidence of pharyngocutaneous fistula has also increased in both respiratory and digestive system surgery. We investigated the effects of recombinant human growth hormone on pharyngocutaneous fistula closure in Sprague-Dawley rats, based on an increase in amino acid uptake and protein synthesis for wound healing, an increase in mitogenesis, and enhancement of collagen formation by recombinant human growth hormone. This study was experimental animal study. Forty Sprague-Dawley rats were separated into two groups, and pharyngoesophagotomy was performed. The pharyngoesophagotomy was sutured with vicryl in both groups. Rats in group 1 (control group) received no treatment, while those in group 2 were administered a subcutaneous injection of recombinant human growth hormone daily. On day 14, the pharynx, larynx, and upper oesophagus were excised and examined microscopically. Pharyngocutaneous fistula exhibited better closure macroscopically in the recombinant human growth hormone group. There was a significant difference in collagen formation and epithelisation in the recombinant human growth hormone group compared to the control group. This study is believed to be the first in which the effect of recombinant human growth hormone on pharyngocutaneous fistula closure was evaluated, and the findings suggest the potential of use of growth hormone for treatment of pharyngocutaneous fistula.

  10. Space Station evolution study oxygen loop closure

    NASA Technical Reports Server (NTRS)

    Wood, M. G.; Delong, D.

    1993-01-01

    In the current Space Station Freedom (SSF) Permanently Manned Configuration (PMC), physical scars for closing the oxygen loop by the addition of oxygen generation and carbon dioxide reduction hardware are not included. During station restructuring, the capability for oxygen loop closure was deferred to the B-modules. As such, the ability to close the oxygen loop in the U.S. Laboratory module (LAB A) and the Habitation A module (HAB A) is contingent on the presence of the B modules. To base oxygen loop closure of SSF on the funding of the B-modules may not be desirable. Therefore, this study was requested to evaluate the necessary hooks and scars in the A-modules to facilitate closure of the oxygen loop at or subsequent to PMC. The study defines the scars for oxygen loop closure with impacts to cost, weight and volume and assesses the effects of byproduct venting. In addition, the recommended scenarios for closure with regard to topology and packaging are presented.

  11. Negative pressure wound therapy combined with acoustic pressure wound therapy for infected post surgery wounds: a case series.

    PubMed

    Howell-Taylor, Melania; Hall, Macy G; Brownlee Iii, William J; Taylor, Mary

    2008-09-01

    Acute infection of surgical incision sites often requires specialized wound care in preparation for surgical closure. Optimal therapy for preparing such wounds for a secondary closure procedure remains uncertain. The authors report wound outcomes after administering acoustic pressure wound therapy in conjunction with negative pressure wound therapy with reticulated open-cell foam dressing changes to assist with bacteria removal from open, infected surgical-incision sites in preparation for secondary surgical closure in three patients. Before incorporating acoustic pressure wound therapy at the authors' facility, the average negative pressure wound therapy with reticulated open-cell foam dressing course prior to secondary surgical closure was 30 days; with its addition, two of three patients underwent successful surgical closure with no postoperative complications after 21 and 14 days, respectively; one patient succumbed to nonwound-related complications before wound closure. Larger, prospective studies are needed to evaluate combining negative pressure wound therapy with reticulated open-cell foam dressing and acoustic pressure wound therapy for infected, acute post surgery wounds.

  12. Biomechanical Testing and Histologic Examination of Intradermal Skin Closure in Dogs Using Barbed Suture Device and Non-Barbed Monofilament Suture.

    PubMed

    Law, Andy Y; Butler, James R; Patnaik, Sourav S; Cooley, James A; Elder, Steven H

    2017-01-01

    To compare the biomechanical strength and histologic features of 3-0 Glycomer™ 631 barbed suture (V-LOC™ 90 Absorbable Wound Closure Device, Covidien, Mansfield, MA) to non-barbed 3-0 Glycomer™ 631 suture (Biosyn™, Covidien) for intradermal skin wound closure in the dog. Randomized, factorial, in vivo. Eighteen purpose-bred, mature male, and female hound dogs. Eighteen adult hound dogs were randomly assigned to 1 of 3 groups designated by postoperative day of assessment. Six skin incisions were made along the dorsum in the thoracolumbar region of each dog with an equal number (n=3) randomly assigned to closure with barbed or non-barbed suture. Six dogs were euthanatized on postoperative days 3, 10, and 14, respectively. Two additional incisions were made on each dog after euthanasia for baseline data (Day 0). The skin incision specimens were harvested for biomechanical testing and histologic evaluation. Non-barbed closure had significantly higher maximum load at failure (P<.001) and stiffness (P<.001) than barbed closure regardless of day. The average tissue reaction score was significantly higher for barbed closure (P=.008), regardless of day. Suturing time for barbed closures was significantly shorter. There was no significant difference in frequency of complications between closures. Barbed Glycomer™ 631 closures had a significantly lower maximum load at failure and stiffness, and higher average tissue reaction scores, but showed no difference in short term outcome for intradermal closure of dorsally located skin incisions in dogs. © 2016 The American College of Veterinary Surgeons.

  13. Laser tissue melding: use of 1.32-μm computerized Nd:YAG laser, results of leak/burst strength studies in microsurgical procedures

    NASA Astrophysics Data System (ADS)

    Anderson, Dallas W.; Hsu, Tung M.; Halpern, Steven J.; Honaker, Arnold

    1993-07-01

    The ProClosureTM System (PCS) consists of a low power 1.32micrometers Nd:YAG laser coupled to a handheld disposable fiber optic device. The system has been designed to perform a wide range of tissue welding applications such as cosmetic skin closure,vascular surgery, and minimally invasive surgical procedures normally performed with sutures and staples. Utilizing a wavelength for tissue fusion that is least distracted by medium in the surgical field coupled with a computerized delivery system allows for a more precise application (+/- 5%) of laser energy to the tissue. The study design involved the micro-surgical anastomosis of twenty Sprague-Dawley rats (vas deferens) and twenty-one Sprague-Dawley rats (femoral arteries). Each rat is its own contralateral control. Laser repair time is approximately one-third that of conventional suturing. Postoperative dissection and burst strength testing was conducted at day 0, 1, 7, and 14. At each postoperative interval, the mean leak/burst strength for laser-assisted closure v. control, was markedly higher. The precise application of energy fluence resulting from ProClosure's computerized system yields an initial strength and a fluid static seal that is superior to conventional suture closure.

  14. [Vacuum-assisted therapy for various wound types including diabetic foot ulcer].

    PubMed

    Farah, Raymond; Gantus, Maher; Kogan, Leonid

    2011-03-01

    Vacuum is a noninvasive system that creates a localized controlled negative pressure environment. In this study, vacuum was provided by the V.A.C. Therapy system, which promotes wound healing by delayed primary or secondary intention through creating a moist wound environment, preparing the wound bed for closure, reducing edema, and promoting formation and perfusion of granulation tissue. Vacuum-assisted closure therapy is indicated for use in all care settings and for a variety of wound types including diabetic foot ulcers. The purpose of this study was to evaluate safety and clinical efficacy of negative pressure wound therapy (NPWT) compared with advanced moist wound therapy and standard treatment to treat foot ulcers in diabetic patients. This trial enrolled 43 patients; most of them were diabetic patients at any age with various skin ulcers and diabetic foot. These patients were divided into two groups, 17 patients were treated with vacuum and the 26 patients in the control group were treated with standard therapy including debridement. A greater proportion of foot and skin ulcers achieved complete ulcer closure with vacuum-assisted therapy p<0.001 compared with the standard therapy. Vacuum therapy significantly decreased the duration and frequency of admission p=0.032 and decreased the rate of amputation p<0.001. Results of our trial support other studies and demonstrate that vacuum is as safe as and more efficacious than standard therapy in the treatment of diabetic foot ulcers. A significantly greater number of patients achieved complete ulcer closure and granulation tissue formation with this therapy. The study group showed a significant reduction in the median time needed to heal ulcers, reduction of the number of admissions and amputation frequency.

  15. Teaching advanced wound closure techniques using cattle digits.

    PubMed

    Khalil, Philipe N; Kanz, Karl-Georg; Siebeck, Matthias; Mutschler, Wolf

    2011-03-01

    To evaluate a model used to impart advanced wound closure skills because available models do not meet the necessary requirements to a substantial degree. Seventy-one residents were asked to evaluate a 75-minute-long skills course using cadaveric cattle digits to learn Z-plasty, V-Y-plasty, and oval-shaped rotational flaps. A short film and the course instructor demonstrated each technique first. A Likert rating scale ranging from 1 to 6 was used for questions in the survey given to the residents. There was strong agreement among residents (1.65 ± 1.17 years of experience) that advanced wound closure training courses are necessary (5.73 ± 0.73), which corresponded to the residents' low level of knowledge and self-assessment of practical skills and present experience (2.84 ± 1.01). The course was evaluated with high acceptance, even though it was found to be demanding for the trainees (5.84 ± 0.40). This might also be related to the high rating of the model itself, which was found to be a suitable method for teaching advanced wound closure techniques (5.50 ± 0.71) that was easily comprehensible (5.73 ± 0.53). Skills training courses for young trainees are warranted to impart advanced wound closure techniques. The curriculum using cattle digits presented here is recommended. The authors have indicated no significant interest with commercial supporters. © 2011 by the American Society for Dermatologic Surgery, Inc.

  16. Spontaneous closure of traumatic macular hole.

    PubMed

    Sanjay, Srinivasan; Yeo, Tun Kuan; Au Eong, Kah-Guan

    2012-07-01

    Macular hole formation is a well-known complication following ocular trauma. Less commonly recognised is the spontaneous closure of such holes. A 27-year-old man presented with a history of blunt trauma to his left eye. Eye evaluation showed conjunctival laceration, diffuse retinal oedema and multiple retinal haemorrhages in that eye. A month later, he developed a full thickness macular hole. Two months later, there was spontaneous complete closure of the full-thickness macular hole in the left eye as confirmed on optical coherence tomography. Spontaneous closure of hole is not uncommon. Observation for a period of up to 12 months is a reasonable management option. Macular hole surgery for traumatic macular holes may be delayed in such cases.

  17. Modified energy cascade model adapted for a multicrop Lunar greenhouse prototype

    NASA Astrophysics Data System (ADS)

    Boscheri, G.; Kacira, M.; Patterson, L.; Giacomelli, G.; Sadler, P.; Furfaro, R.; Lobascio, C.; Lamantea, M.; Grizzaffi, L.

    2012-10-01

    Models are required to accurately predict mass and energy balances in a bioregenerative life support system. A modified energy cascade model was used to predict outputs of a multi-crop (tomatoes, potatoes, lettuce and strawberries) Lunar greenhouse prototype. The model performance was evaluated against measured data obtained from several system closure experiments. The model predictions corresponded well to those obtained from experimental measurements for the overall system closure test period (five months), especially for biomass produced (0.7% underestimated), water consumption (0.3% overestimated) and condensate production (0.5% overestimated). However, the model was less accurate when the results were compared with data obtained from a shorter experimental time period, with 31%, 48% and 51% error for biomass uptake, water consumption, and condensate production, respectively, which were obtained under more complex crop production patterns (e.g. tall tomato plants covering part of the lettuce production zones). These results, together with a model sensitivity analysis highlighted the necessity of periodic characterization of the environmental parameters (e.g. light levels, air leakage) in the Lunar greenhouse.

  18. Evaluation of high-performance fiber-reinforced concrete for bridge deck connections, closure pours, and joints : final report.

    DOT National Transportation Integrated Search

    2017-01-01

    Connections, closure pours, and joints in bridges are often sources of distress because of cracks and openings. Wide separation facilitates the penetration of harmful solutions that can lead to costly repairs. Cracks are caused by volumetric changes ...

  19. Assessing Hydrologic Impacts of Land Configuration Changes Using an Integrated Hydrologic Model at the Rocky Flats Environmental Technology Site, Colorado

    NASA Astrophysics Data System (ADS)

    Prucha, R. H.; Dayton, C. S.; Hawley, C. M.

    2002-12-01

    The Rocky Flats Environmental Technology Site (RFETS) in Golden, Colorado, a former Department of Energy nuclear weapons manufacturing facility, is currently undergoing closure. The natural semi-arid interaction between surface and subsurface flow at RFETS is complex and complicated by the industrial modifications to the flow system. Using a substantial site data set, a distributed parameter, fully-integrated hydrologic model was developed to assess the hydrologic impact of different hypothetical site closure configurations on the current flow system and to better understand the integrated hydrologic behavior of the system. An integrated model with this level of detail has not been previously developed in a semi-arid area, and a unique, but comprehensive, approach was required to calibrate and validate the model. Several hypothetical scenarios were developed to simulate hydrologic effects of modifying different aspects of the site. For example, some of the simulated modifications included regrading the current land surface, changing the existing surface channel network, removing subsurface trenches and gravity drain flow systems, installing a slurry wall and geotechnical cover, changing the current vegetative cover, and converting existing buildings and pavement to permeable soil areas. The integrated flow model was developed using a rigorous physically-based code so that realistic design parameters can simulate these changes. This code also permitted evaluation of changes to complex integrated hydrologic system responses that included channelized and overland flow, pond levels, unsaturated zone storage, groundwater heads and flow directions, and integrated water balances for key areas. Results generally show that channel flow offsite decreases substantially for different scenarios, while groundwater heads generally increase within the reconfigured industrial area most of which is then discharged as evapotranspiration. These changes have significant implications to site closure and operation.

  20. Comparison of Free-Beam- and Fiber-Type CO2 Laser Delivery Systems in Stapes Surgery.

    PubMed

    Chang, Mun Young; Choi, Hyun Seok; Lee, Sang-Youp; Koo, Ja-Won

    2017-07-01

    A free-beam-type CO 2 laser, which use a micromanipulator mounted on a microscope as the delivery system, has the merit of not being affected by hand tremor at the time of shooting. However, this delivery system has several disadvantages, including a restricted operation range and a risk of incorrect focusing. A fiber-type CO 2 laser uses a hand-held delivery system and has the opposite merits and demerits. We compared the results of stapes surgery with free-beam and fiber type delivery systems. The study enrolled 36 patients who underwent stapedotomy with free-beam- (n=26) or fiber- (n=10) type CO 2 lasers. The air-bone (AB) gap closure, bone conduction (BC) change, and operating time were evaluated. The AB gap closure was calculated by subtracting the preoperative BC thresholds from the postoperative air conduction thresholds. The BC change was calculated by subtracting the postoperative BC thresholds from the preoperative BC thresholds. The mean operating time was significantly ( p =0.035) shorter in the fiber-type group (72.5±8.2 min) than in the free-beam-type group (80.5±11.4 min). The mean AB gap closure did not differ significantly ( p =0.297) between the free-beamand fiber-type groups (5.8±10.1 and 1.4±6.8 dB, respectively). The mean BC change did not differ significantly ( p =0.873) between the free-beam- and fiber-type groups (2.4±6.9 and 2.8±5.3 dB, respectively). The hearing outcomes did not differ significantly between the two groups. Operating times were significantly shorter using the fiber-type CO 2 laser, while hearing outcomes did not differ significantly between the two groups.

  1. Trace Contaminant Control for the International Space Station's Node 1- Analysis, Design, and Verification

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    2017-01-01

    Trace chemical contaminant generation inside crewed spacecraft cabins is a technical and medical problem that must be continuously evaluated. Although passive control through materials selection and active control by adsorption and catalytic oxidation devices is employed during normal operations of a spacecraft, contaminant buildup can still become a problem. Buildup is particularly troublesome during the stages between the final closure of a spacecraft during ground processing and the time that a crewmember enters for the first time during the mission. Typically, the elapsed time between preflight closure and first entry on orbit for spacecraft such as Spacelab modules was 30 days. During that time, the active contamination control systems are not activated and contaminants can potentially build up to levels which exceed the spacecraft maximum allowable concentrations (SMACs) specified by NASA toxicology experts. To prevent excessively high contamination levels at crew entry, the Spacelab active contamination control system was operated for 53 hours just before launch.

  2. Cystic Duct Closure by Sealing With Bipolar Electrocoagulation

    PubMed Central

    Damgaard, B.; Jorgensen, L. N.; Larsen, S. S.; Kristiansen, V. B.

    2010-01-01

    Background: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure®) for closure of the cystic duct. Methods: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. Results: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. Conclusion: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. PMID:20412641

  3. Analysis of Mining-induced Valley Closure Movements

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Mitra, R.; Oh, J.; Hebblewhite, B.

    2016-05-01

    Valley closure movements have been observed for decades in Australia and overseas when underground mining occurred beneath or in close proximity to valleys and other forms of irregular topographies. Valley closure is defined as the inward movements of the valley sides towards the valley centreline. Due to the complexity of the local geology and the interplay between several geological, topographical and mining factors, the underlying mechanisms that actually cause this behaviour are not completely understood. A comprehensive programme of numerical modelling investigations has been carried out to further evaluate and quantify the influence of a number of these mining and geological factors and their inter-relationships. The factors investigated in this paper include longwall positional factors, horizontal stress, panel width, depth of cover and geological structures around the valley. It is found that mining in a series passing beneath the valley dramatically increases valley closure, and mining parallel to valley induces much more closure than other mining orientations. The redistribution of horizontal stress and influence of mining activity have also been recognised as important factors promoting valley closure, and the effect of geological structure around the valley is found to be relatively small. This paper provides further insight into both the valley closure mechanisms and how these mechanisms should be considered in valley closure prediction models.

  4. 40 CFR 266.102 - Permit standards for burners.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...

  5. 40 CFR 266.102 - Permit standards for burners.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...

  6. 40 CFR 266.102 - Permit standards for burners.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...

  7. 40 CFR 266.102 - Permit standards for burners.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...

  8. 40 CFR 266.102 - Permit standards for burners.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...

  9. A computable expression of closure to efficient causation.

    PubMed

    Mossio, Matteo; Longo, Giuseppe; Stewart, John

    2009-04-07

    In this paper, we propose a mathematical expression of closure to efficient causation in terms of lambda-calculus; we argue that this opens up the perspective of developing principled computer simulations of systems closed to efficient causation in an appropriate programming language. An important implication of our formulation is that, by exhibiting an expression in lambda-calculus, which is a paradigmatic formalism for computability and programming, we show that there are no conceptual or principled problems in realizing a computer simulation or model of closure to efficient causation. We conclude with a brief discussion of the question whether closure to efficient causation captures all relevant properties of living systems. We suggest that it might not be the case, and that more complex definitions could indeed create crucial some obstacles to computability.

  10. Efficacy and safety of non-suture dural closure using a novel dural substitute consisting of polyglycolic acid felt and fibrin glue to prevent cerebrospinal fluid leakage-A non-controlled, open-label, multicenter clinical trial.

    PubMed

    Terasaka, Shunsuke; Taoka, Toshiaki; Kuroda, Satoshi; Mikuni, Nobutaka; Nishi, Toru; Nakase, Hiroyuki; Fujii, Yukihiko; Hayashi, Yasuhiko; Murata, Jun-Ichi; Kikuta, Ken-Ichiro; Kuroiwa, Toshihiko; Shimokawa, Sachie; Houkin, Kiyohiro

    2017-05-01

    The objective of this study is to evaluate the efficacy and safety of non-suture dural closure using a novel dural substitute (GM111) consisting of polyglycolic acid felt with a fibrin-glue-coated area commensurate in size with the dural defect. This was a non-controlled, open-label, multicenter clinical trial. The efficacy evaluation endpoints were (1) GM111's intra-operative capability to close dural defects and (2) prevention of cerebrospinal fluid (CSF) leakage and subcutaneous CSF retention throughout the postoperative period (evaluated by diagnostic imaging). Patients meeting the following three preoperative and two intra-operative selection criteria were enrolled: (1) between 12 and <75 years of age; (2) the dura is surmised to be defective and in need of reconstruction; (3) informed written consent was obtained from the patient; (4) the surgical wound is class 1; and (5) the size of duraplasty is ≥0.2 cm 2 to <100 cm 2 . Sixty patients were enrolled. The craniotomy site was supratentorial in 77.2%, infratentorial in 12.3% and sellar in 10.5%. The GM111 prosthesis size ranged from 0.24 to 42 cm 2 . To evaluate the efficacy, intra-operative closure was confirmed by Valsalva's maneuver, water infusion, etc., in all patients. CSF leakage and subcutaneous CSF retention throughout the postoperative period were found in four patients. Adverse events for which a causal relationship with GM111 could not be ruled out occurred in 8.8% of the patients. There were no instances of postoperative infection due to GM111. GM111 showed good closure capability and safety when used for non-suture dural closure.

  11. Performance characteristics of a novel blood bag in-line closure device and subsequent product quality assessment

    PubMed Central

    Serrano, Katherine; Levin, Elena; Culibrk, Brankica; Weiss, Sandra; Scammell, Ken; Boecker, Wolfgang F; Devine, Dana V

    2010-01-01

    BACKGROUND In high-volume processing environments, manual breakage of in-line closures can result in repetitive strain injury (RSI). Furthermore, these closures may be incorrectly opened causing shear-induced hemolysis. To overcome the variability of in-line closure use and minimize RSI, Fresenius Kabi developed a new in-line closure, the CompoFlow, with mechanical openers. STUDY DESIGN AND METHODS The consistency of the performance of the CompoFlow closure device was assessed, as was its effect on component quality. A total of 188 RBC units using CompoFlow blood bag systems and 43 using the standard bag systems were produced using the buffy coat manufacturing method. Twenty-six CompoFlow platelet (PLT) concentrates and 10 control concentrates were prepared from pools of four buffy coats. RBCs were assessed on Days 1, 21, and 42 for cellular variables and hemolysis. PLTs were assessed on Days 1, 3, and 7 for morphology, CD62P expression, glucose, lactate, and pH. A total of 308 closures were excised after processing and the apertures were measured using digital image analysis. RESULTS The use of the CompoFlow device significantly improved the mean extraction time with 0.46 ± 0.11 sec/mL for the CompoFlow units and 0.52 ± 0.13 sec/mL for the control units. The CompoFlow closures showed a highly reproducible aperture after opening (coefficient of variation, 15%) and the device always remained opened. PLT and RBC products showed acceptable storage variables with no differences between CompoFlow and control. CONCLUSIONS The CompoFlow closure devices improved the level of process control and processing time of blood component production with no negative effects on product quality. PMID:20529007

  12. Evaluation of airway protection: Quantitative timing measures versus penetration/aspiration score.

    PubMed

    Kendall, Katherine A

    2017-10-01

    Quantitative measures of swallowing function may improve the reliability and accuracy of modified barium swallow (MBS) study interpretation. Quantitative study analysis has not been widely instituted, however, secondary to concerns about the time required to make measures and a lack of research demonstrating impact on MBS interpretation. This study compares the accuracy of the penetration/aspiration (PEN/ASP) scale (an observational visual-perceptual assessment tool) to quantitative measures of airway closure timing relative to the arrival of the bolus at the upper esophageal sphincter in identifying a failure of airway protection during deglutition. Retrospective review of clinical swallowing data from a university-based outpatient clinic. Swallowing data from 426 patients were reviewed. Patients with normal PEN/ASP scores were identified, and the results of quantitative airway closure timing measures for three liquid bolus sizes were evaluated. The incidence of significant airway closure delay with and without a normal PEN/ASP score was determined. Inter-rater reliability for the quantitative measures was calculated. In patients with a normal PEN/ASP score, 33% demonstrated a delay in airway closure on at least one swallow during the MBS study. There was no correlation between PEN/ASP score and airway closure delay. Inter-rater reliability for the quantitative measure of airway closure timing was nearly perfect (intraclass correlation coefficient = 0.973). The use of quantitative measures of swallowing function, in conjunction with traditional visual perceptual methods of MBS study interpretation, improves the identification of airway closure delay, and hence, potential aspiration risk, even when no penetration or aspiration is apparent on the MBS study. 4. Laryngoscope, 127:2314-2318, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Evaluation of Elber's Crack Closure Model as an Explanation of Train Load Sequence Effects on Crack Growth Rates

    DOT National Transportation Integrated Search

    1990-06-01

    Elber's crack closure model is studied in relation to the results of laboratory spectrum crack growth tests on compact tension specimens (CTS) fabricated from rail effected by mean of an analysis of a center cracked panel (CCP) subjected to an equiva...

  14. DETERMINATION OF OPTIMAL TOXICANT LOADING FOR BIOLOGICAL CLOSURE OF A HAZARDOUS WASTE SITE

    EPA Science Inventory

    Information on Phase I and Phase Il of a multitask effort to achieve biological closure of an abandoned hazardous waste site. aste materials, in the form of buried sludges and lagoon wastes, were examined. ptimal loading levels were evaluated on the basis of biodegradative potent...

  15. The effect of tourniquet and knee position during wound closure after total knee arthroplasty on early recovery of range of motion: a prospective, randomized study.

    PubMed

    Şükür, Erhan; Öztürkmen, Yusuf; Akman, Yunus Emre; Senel, Ahmet; Azboy, İbrahim

    2016-12-01

    There is no consensus on the position of the knee joint while performing wound closure after total knee arthroplasty (TKA). Further, there are no studies focusing on the association between early functional outcomes and different wound closure strategies. Therefore, we investigated the effects of tourniquet and knee position during wound closure on early recovery of range of motion (ROM) after primary TKA. To our knowledge, this is the first study to evaluate the influence of both tourniquet and knee position during wound closure in primary TKA. One hundred-twenty eligible patients were consecutively enrolled in this study and randomly divided into four groups according to wound closure strategy. Wound closure was either performed with the knee in flexion at 90° or in full extension, with the combination of an inflated or deflated tourniquet. Visual analogue score (VAS), knee ROM, ROM recovery, knee society score (KSS), and wound complications were evaluated in the early postoperative period. After the first postoperative week, ROM recovery in the group with knee in extension and inflated tourniquet was significantly lesser than the two groups with deflated tourniquets. Between the first and fourth postoperative weeks, ROM recovery in the group with knee inflection and deflated tourniquet was significantly higher than the two groups with knee in extension. After the first postoperative week, the visual analog score (VAS) for pain in the group with knee inflection and deflated tourniquet was significantly lesser than the two groups with inflated tourniquets. The differences in the outcomes between the four groups were not significant after the fourth postoperative week. The incidence of wound complications and KSS were not significantly different between the four groups. Following TKA, wound closure with the knee in flexion and after deflating the tourniquet significantly decreased postoperative pain and promoted the recovery of ROM in the early postoperative period.

  16. Closure Report for Corrective Action Unit 356: Mud Pits and Disposal Sites, Nevada Test Site, Nevada with Errata Sheet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NNSA /NV

    2002-11-12

    This Closure Report (CR) has been prepared for Corrective Action Unit (CAU) 356, Mud Pits and Disposal Sites, in accordance with the Federal Facility Agreement and Consent Order. This CAU is located in Areas 3 and 20 of the Nevada Test Site (NTS) approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 356 consists of seven Corrective Action Sites (CASs): 03-04-01, Area 3 Change House Septic System; 03-09-01, Mud Pit Spill Over; 03-09-03, Mud Pit; 03-09-04, Mud Pit; 03-09-05, Mud Pit; 20-16-01, Landfill; and 20-22-21, Drums. This CR identifies and rationalizes the U.S. Department of Energy (DOE), Nationalmore » Nuclear Security Administration Nevada Operations Office's (NNSA/NV's) recommendation that no further corrective action and closure in place is deemed necessary for CAU 356. This recommendation is based on the results of field investigation/closure activities conducted November 20, 2001, through January 3, 2002, and March 11 to 14, 2002. These activities were conducted in accordance with the Streamlined Approach for Environmental Restoration Plan (SAFER) for CAU 356. For CASs 03-09-01, 03-09-03, 20-16-01, and 22-20-21, analytes detected in soil during the corrective action investigation were evaluated against Preliminary Action Levels (PALs) and it was determined that no Contaminants of Concern (COCs) were present. Therefore, no further action is necessary for the soil at these CASs. For CASs 03-04-01, 03-09-04, and 03-09-05, analytes detected in soil during the corrective action investigation were evaluated against PALs and identifies total petroleum hydrocarbons (TPHs) and radionuclides (i.e., americium-241 and/or plutonium 239/240) as COCs. The nature, extent, and concentration of the TPH and radionuclide COCs were bounded by sampling and shown to be relatively immobile. Therefore, closure in place is recommended for these CASs in CAU 356. Further, use restrictions are not required at this CAU beyond the NTS use restrictions identified in the SAFER Plan. In addition, the septic tank associated with CAU 356 will be closed in accordance with applicable regulations.« less

  17. Corporate social responsibility for regional sustainability after mine closure: a case study of mining company in Indonesia

    NASA Astrophysics Data System (ADS)

    Syarif, Andi Erwin; Hatori, Tsuyoshi

    2017-06-01

    Creating a soft-landing path for mine closure is key to the sustainability of the mining region. In this research, we presents a case of mine closure in Soroako, a small mining town in the north-east of South Sulawesi province, in the center of Sulawesi Island in Indonesia. Especially we investigates corporate social responsibility (CSR) programs of a mining company, PT Vale Indonesia Tbk (PTVI), towards a soft-landing of mine closure in this region. The data of the CSR programs are gathered from in-depth interviews, the annual reports and managerial reports. Furthermore we presents an integrated view of CSR to close mining in a sustainable manner. We then evaluate CSR strategies of the company and its performance from this viewpoint. Based on these steps, the way to improve the CSR mine closure scenario for enhancing the regional sustainability is discussed and recommended.

  18. A quantitative investigation of the fracture pump-in/flowback test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plahn, S.V.; Nolte, K.G.; Thompson, L.G.

    1997-02-01

    Fracture-closure pressure is an important parameter for fracture treatment design and evaluation. The pump-in/flowback (PIFB) test is frequently used to estimate its magnitude. The test is attractive because bottomhole pressures (BHP`s) during flowback develop a distinct and repeatable signature. This is in contrast to the pump-in/shut-in test, where strong indications of fracture closure are rarely seen. Various techniques are used to extract closure pressure from the flowback-pressure response. Unfortunately, these techniques give different estimates for closure pressure, and their theoretical bases are not well established. The authors present results that place the PIFB test on a firmer foundation. A numericalmore » model is used to simulate the PIFB test and glean physical mechanisms contributing to the response. On the basis of their simulation results, they propose interpretation techniques that give better estimates of closure pressure than existing techniques.« less

  19. A quantitative investigation of the fracture pump-in/flowback test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plahn, S.V.; Nolte, K.G.; Miska, S.

    1995-12-31

    Fracture closure pressure is an important parameter for fracture treatment design and evaluation. The pump-in/flowback (PIFB) test is frequently used to estimate its magnitude. The test is attractive because bottomhole pressures during flowback develop a distinct and repeatable signature. This is in contrast to the pump-in/shut-in test where strong indications of fracture closure are rarely seen. Various techniques exist for extracting closure pressure from the flowback pressure response. Unfortunately, these procedures give different estimates for closure pressure and their theoretical bases are not well established. We present results that place the PIFB test on a more solid foundation. A numericalmore » model is used to simulate the PIFB test and glean physical mechanisms contributing to the response. Based on our simulation results, we propose an interpretation procedure which gives better estimates for closure pressure than existing techniques.« less

  20. Limited utility of preoperative studies in preparation for colostomy closure.

    PubMed

    Pokorny, R M; Heniford, T; Allen, J W; Tuckson, W B; Galandiuk, S

    1999-04-01

    Numerous diagnostic and therapeutic practices are used in an attempt to reduce the morbidity of colostomy closures. Our principal aim was to evaluate the role of preoperative studies, specifically barium enemas and endoscopic examinations, performed before colostomy closures. Additionally, we wished to identify other practices involved in the perioperative management of patients undergoing colostomy closure that influenced morbidity. The records of 100 consecutive patients who underwent elective colostomy closure at University of Louisville Hospital between January 1989 and July 1995 were reviewed. Wound infection was the most common complication (12%). Various bowel preparations were equivalent in efficacy and did not influence the complication rate. Intermittent wound irrigation with antibiotics for 3 days postoperatively, via subcutaneous drains, was associated with a low incidence of incision infection. Preoperative barium enema or sigmoidoscopy were often performed but rarely useful. Performing these examinations merely increased hospital cost without a corresponding decline in morbidity.

  1. Oral versus intravenous paracetamol: which is better in closure of patent ductus arteriosus in very low birth weight infants?

    PubMed

    Sancak, Selim; Gokmen Yildirim, Tulin; Topcuoglu, Sevilay; Yavuz, Taner; Karatekin, Guner; Ovali, Fahri

    2016-01-01

    To compare the efficacy of oral and intravenous paracetamol for closure of hemodynamically significant patent ductus arteriosus (HSPDA) in very low birth weight (VLBW) preterm infants. Eighteen VLBW infants with HSPDA treated with either intravenous (n = 10) or oral (n = 8) paracetamol at 60 mg/kg/d for three consecutive days were analysed retrospectively. Ductal closure rate and evaluation of liver function tests were the major outcomes. After two courses of treatment, HSPDA closure rate was higher in oral paracetamol group than that in the intravenous paracetamol group (88% versus 70%), but it was not statistically significant (p = 0.588). Liver function tests were normal after the treatment. Although it was not statistically significant, the cumulative closure rates were higher in oral paracetamol group than those in the intravenous group. Larger trials are needed to confirm these data.

  2. Open abdomen treatment for septic patients with gastrointestinal fistula: from fistula control to definitive closure.

    PubMed

    Ren, Jianan; Yuan, Yujie; Zhao, Yunzhao; Gu, Guosheng; Wang, Gefei; Chen, Jun; Fan, Chaogang; Wang, Xinbo; Li, Jieshou

    2014-04-01

    The use of open abdomen in the management of gastrointestinal fistula complicated with severe intra-abdominal infection is uncommon. This study was designed to evaluate outcomes of our staged approach for the infected open abdomen. Patients who had gastrointestinal fistula and underwent open abdomen treatment were retrospectively reviewed. Various materials such as polypropylene mesh and a modified sandwich package were used to achieve temporary abdominal closure followed by skin grafting when the granulation bed matured. A delayed definitive operation was performed for final abdominal closure without implant of prosthetic mesh. Between 1999 and 2009, 56 (68.3%) of 82 patients survived through this treatment. Among them, 42 patients achieved final abdominal closure. Spontaneous fistula closure occurred in 16 patients with secondary fistula recorded in six patients. Besides, wound complications occurred in 13 patients with two cases for pulmonary infection. Within a 12-month follow-up period after definitive closure, no additional fistula was recorded excluding planned ventral hernia repair. Open abdomen treatment was effective for gastrointestinal fistula complicated by severe intra-abdominal infection. A delayed and deliberate operative strategy aiming at fistula excision and fascial closure, with simultaneous abdominal wall reconstruction, was required for the infected open abdomen.

  3. Multidisciplinary management of patent foramen ovale (PFO) and cryptogenic stroke/TIA

    PubMed Central

    Mirzada, Naqibullah; Ladenvall, Per; Hansson, Per-Olof; Eriksson, Peter; Dellborg, Mikael

    2013-01-01

    Purpose Patent foramen ovale (PFO) has been implicated as a risk factor for cryptogenic ischemic stroke (CS). However, there is still a lack of widely accepted, undisputed indications for PFO closure. The present study describes the concept of the multidisciplinary PFO conference and a decision making process for closure versus no closure that was developed into a formalized clinical algorithm, and presents the results of implementing these, in terms of number and proportion of PFO closures as well as repeat referrals. Design Five specialists in neurology, cardiology, internal medicine, thromboembolism, and echocardiography evaluated the clinical data of 311 patients at PFO conferences during 2006 to 2009. The main criteria for closure were patients with first-ever CS with PFO and atrial septal aneurysm, or patients with recurrent CS and PFO without atrial septal aneurysm. Results A total of 143 patients (46%) were accepted for closure and 167 patients were rejected. Patients accepted for closure were younger (mean 50 years versus 58 years) (P < 0.001). The acceptance rate for PFO closure was similar throughout these years, with an average of 45%. Three of 167 patients (1.8%) initially rejected for PFO closure were re-referred due to recurrent stroke, and the PFO closure was subsequently performed. Conclusion The acceptance rate of less than 50% in the present study underscores the complex relationship between CS and PFO. Whatever the criteria used for PFO closure, any unit caring for these patients needs to have a rigorous process to avoid overtreatment as well as undertreatment and to ensure that personal preferences and economic incentives do not steer the selection process. Our algorithm provides a stable acceptance rate and a low rate of repeat referrals. PMID:24082787

  4. Analysis of randomly time varying systems by gaussian closure technique

    NASA Astrophysics Data System (ADS)

    Dash, P. K.; Iyengar, R. N.

    1982-07-01

    The Gaussian probability closure technique is applied to study the random response of multidegree of freedom stochastically time varying systems under non-Gaussian excitations. Under the assumption that the response, the coefficient and the excitation processes are jointly Gaussian, deterministic equations are derived for the first two response moments. It is further shown that this technique leads to the best Gaussian estimate in a minimum mean square error sense. An example problem is solved which demonstrates the capability of this technique for handling non-linearity, stochastic system parameters and amplitude limited responses in a unified manner. Numerical results obtained through the Gaussian closure technique compare well with the exact solutions.

  5. Final closure of a low level waste disposal facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potier, J.M.

    1995-12-31

    The low-level radioactive waste disposal facility operated by the Agence Nationale pour la Gestion des Dechets Radioactifs near La Hague, France was opened in 1969 and is scheduled for final closure in 1996. The last waste package was received in June 1994. The total volume of disposed waste is approximately 525,000 m{sup 3}. The site closure consists of covering the disposal structures with a multi-layer impervious cap system to prevent rainwater from infiltrating the waste isolation system. A monitoring system has been set up to verify the compliance of infiltration rates with hydraulic performance objectives (less than 10 liters permore » square meter and per year).« less

  6. Predictors of transient left ventricular dysfunction following transcatheter patent ductus arteriosus closure in pediatric age.

    PubMed

    Agha, Hala Mounir; Hamza, Hala S; Kotby, Alyaa; Ganzoury, Mona E L; Soliman, Nanies

    2017-10-01

    To evaluate the left ventricular function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure, and to identify the predictors of myocardial dysfunction post-PDA closure if present. Transcatheter PDA closure; conventional, Doppler, and tissue Doppler imaging; and speckle tracking echocardiography. To determine the feasibility and reliability of tissue Doppler and myocardial deformation imaging for evaluating myocardial function in children undergoing transcatheter PDA closure. Forty-two children diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler, and tissue Doppler imaging, and speckle-derived strain rate echocardiography were performed at preclosure and at 48 hours, 1 month, and 6 months postclosure. Tissue Doppler velocities of the lateral and septal mitral valve annuli were obtained. Global and regional longitudinal peak systolic strain values were determined using two-dimensional speckle tracking echocardiography. The median age of the patients was 2 years and body weight was 15 kg, with the mean PDA diameter of 3.11 ± 0.99 mm. M-mode measurements (left ventricular end diastolic diameter, left atrium diameter to aortic annulus ratio, ejection fraction, and shortening fraction) reduced significantly early after PDA closure ( p  < 0.001). After 1 month, left ventricular end diastolic diameter and left atrium diameter to aortic annulus ratio continued to decrease, while ejection fraction and fractional shortening improved significantly. All tissue Doppler velocities showed a significant decrease at 48 hours with significant prolongation of global myocardial function ( p  < 0.001) and then were normalized within 1 month postclosure. Similarly, global longitudinal strain significantly decreased at 48 hours postclosure ( p  < 0.001), which also recovered at 1 month follow-up. Preclosure global longitudinal strain showed a good correlation with the postclosure prolongation of the myocardial performance index. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure, which recovers completely within 1 month. Preclosure global longitudinal strain can be a predictor of postclosure myocardial dysfunction.

  7. Comparison of two spectral domain optical coherence tomography devices for angle-closure assessment.

    PubMed

    Quek, Desmond T; Narayanaswamy, Arun K; Tun, Tin A; Htoon, Hla M; Baskaran, Mani; Perera, Shamira A; Aung, Tin

    2012-08-03

    To compare two spectral domain optical coherence tomography (SD-OCT) devices for the identification of angle structures and the presence of angle closure. This was a prospective comparative study. Consecutive patients underwent gonioscopy and anterior segment imaging using two SD-OCT devices (iVue and Cirrus). Images were evaluated for the ability to detect angle structures such as Schwalbe's line (SL), trabecular meshwork (TM), Schlemm's canal (SC), and scleral spur (SS), and the presence of angle closure. Angle closure was defined as iris contact with the angle wall anterior to the SS on SD-OCT, and nonvisibility of the posterior TM on gonioscopy. Angle closure in an eye was defined as ≥two quadrants of closed angles. AC1 statistic was used to assess the agreement between devices. Of the 69 subjects studied (46.4% male, 84.1% Chinese, mean age 64.0 ± 10.5 years), 40 subjects (40 eyes, 58.0%) had angle closure on gonioscopy. The most identifiable structure on Cirrus SD-OCT was the SS (82.2%) and SL on iVue SD-OCT (74.5%). Angle closure was indeterminable in 14.5% and 50.7% of Cirrus and iVue scans (P < 0.001), respectively. Interdevice agreement for angle closure was moderately strong (AC1 = 0.67), but agreement with gonioscopy was only fair (AC1 = 0.35 and 0.50 for Cirrus and iVue, respectively). It was more difficult to determine angle closure status with iVue compared with Cirrus SD-OCT. There was fair agreement between both devices with gonioscopy for identifying angle closure.

  8. Qualitative evaluation of the iris and ciliary body by ultrasound biomicroscopy in subjects with angle closure.

    PubMed

    Ku, Judy Y; Nongpiur, Monisha E; Park, Judy; Narayanaswamy, Arun K; Perera, Shamira A; Tun, Tin A; Kumar, Rajesh S; Baskaran, Mani; Aung, Tin

    2014-12-01

    To qualitatively analyze anterior chamber structures imaged by ultrasound biomicroscopy (UBM) in primary angle-closure patients. Subjects diagnosed as primary angle-closure suspect (PACS), primary angle-closure glaucoma (PACG), and previous acute primary angle closure (APAC) were recruited prospectively along with a group of normal controls. UBM was performed under standardized dark room conditions and qualitative assessment was carried out using a set of reference photographs of standard UBM images to categorize the various anatomic features related to angle configuration. These included overall and basal iris thicknesses, iris convexity, iris angulation, ciliary body size, and ciliary sulcus. A total of 60 PACS, 114 PACG, 41 APAC, and 33 normal controls were included. Patients were predominantly older Chinese females. After controlling the confounding effect of age and sex, eyes with overall thicker irides [medium odds ratio (OR) 3.58, thick OR 2.84] when compared with thin irides have a significantly higher likelihood of having PACS/PACG/APAC versus controls. Thicker basal iris component (medium OR 4.13, thick OR 3.39) also have higher likelihood of having angle closure when compared with thin basal iris thickness. Subjects with basal iris insertion, mild iris angulation, and large ciliary body have a higher OR of having angle closure. In contrast, the presence/absence of a ciliary sulcus did not influence the likelihood of angle closure. Eyes with thicker overall and basal iris thicknesses are more likely to have angle closure than controls. Other features that increase the likelihood of angle closure include basal iris insertion, mild iris angulation, and large ciliary body.

  9. New laser soldering-based closures: a promising method in natural orifice transluminal endoscopic surgery.

    PubMed

    Bogni, Serge; Ortner, Maria-Anna; Vajtai, Istvan; Jost, Christian; Reinert, Michael; Dallemagne, Bernard; Frenz, Martin

    2012-07-01

    Complete closure of gastrotomy is the linchpin of safe natural orifice transgastric endoscopic surgery. To evaluate feasibility and efficacy of a new method of gastrotomy closure by using a sutureless laser tissue-soldering (LTS) technique in an ex vivo porcine stomach. In vitro experiment. Experimental laboratory. Histological analysis and internal and external liquid pressure with and without hydrochloric acid exposure were determined comparing gastrotomy closure with LTS and with hand-sewn surgical sutures. Comparison of LTS and hand-sewn surgical gastrotomy closure. The primary outcome parameter was the internal leak pressure. Secondary parameters were the difference between internal and external leak pressures, the impact of an acid environment on the device, histological changes, and feasibility of endoscopic placement. The internal liquid leak pressure after LTS was almost twice as high as after hand-sewn surgical closure (416 ± 53 mm Hg vs 229 ± 99 mm Hg; P = .01). The internal leak pressure (416 ± 53 mm Hg) after LTS was higher than the external leak pressure (154 ± 46 mm Hg; P < .0001). An acidic environment did not affect leak pressure after LTS. Endoscopic LTS closure was feasible in all experiments. Histopathology revealed only slight alterations beneath the soldering plug. In vitro experiments. Leak pressure after LTS closure of gastrotomy is higher than after hand-sewn surgical closure. LTS is a promising technique for closure of gastrotomies and iatrogenic perforations. Further experiments, in particular survival studies, are mandatory. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  10. California Emergency Department Closures Are Associated With Increased Inpatient Mortality At Nearby Hospitals

    PubMed Central

    Liu, Charles; Srebotnjak, Tanja; Hsia, Renee Y.

    2014-01-01

    Between 1996 and 2009 the annual number of emergency department (ED) visits in the United States increased by 51 percent while the number of EDs nationwide decreased by 6 percent, which placed unprecedented strain on the nation’s EDs. To investigate the effects of an ED closing on surrounding communities, we identified all ED closures in California during the period 1999–2010 and examined their association with inpatient mortality rates at nearby hospitals. We found that 24.9 percent of hospital admissions in this period occurred near an ED closure, and that these admissions had 5 percent higher odds of inpatient mortality than admissions not occurring near a closure. This association persisted whether we considered ED closures as affecting all future nearby admissions or only those occurring in the subsequent two years. These results suggest that ED closures have ripple effects on patient outcomes that should be considered when health systems and policy makers decide how to regulate ED closures. PMID:25092832

  11. Effect of a part-span variable inlet guide vane on the performance of a high-bypass turbofan engine

    NASA Technical Reports Server (NTRS)

    Bobula, G. A.; Soeder, R. H.; Burkardt, L. A.

    1981-01-01

    The ability of a part span variable inlet guide vane (VIGV) to modulate the thrust of a high bypass turbofan engine was evaluated at altitude/Mach number conditions of 4572 m/0.6 and 9144 m/0.93. Fan tip, gas generator and supercharger performance were also determined, both on operating lines and during fan duct throttling. The evaluation was repeated with the bypass splitter extended forward to near the fan blade trailing edge. Gross thrust attentuation of over 50 percent was achieved with 50 degree VIGV closure at 100 percent corrected fan speed. Gas generator supercharger performance fell off with VIGV closure, but this loss was reduced when a splitter extension was added. The effect of VIVG closure on gas generator performance was minimal.

  12. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery.

    PubMed

    Oh, You Na; Ha, Keong Jun; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won

    2015-08-01

    Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578), major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99), minor wound complications (3.6% vs. 2.0%, p=0.279), or mediastinitis (0.8% vs. 1.0%, p=1.00). Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068). The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  13. Increased patient delays in care after the closure of Martin Luther King Hospital: implications for monitoring health system changes.

    PubMed

    Walker, Kara Odom; Leng, Mei; Liang, Li-Jung; Forge, Nell; Morales, Leo; Jones, Loretta; Brown, Arleen

    2011-01-01

    The safety net system remains an important part of the health care system for uninsured and minority populations, however, the closure of safety net hospitals changes the availability of care. Using community-based participatory research methods, we explored the impact of hospital closure among late middle aged and elderly racial/ethnic minorities in South Los Angeles. Telephone survey of participants in both 2008, after hospital closure, and 2003, before hospital closure, who self-identified as African American or Latino, were over the age of 50 and lived in zip codes of South Los Angeles. We developed multiple logistic regression models on imputed data sets weighted for non-response and adjusted for self-reported measures of demographic and clinical characteristics to examine the odds of reporting delays in care. After adjusting for covariates known to influence access to care and distributed differently in the two survey samples, we found significantly greater delays in care. Following the closure of the Martin Luther King, Jr. safety net hospital, the adjusted odds ratios were 1.70 (95% CI 1.01, 2.87) for delays in care, 1.88 (95% Cl 1.06, 3.13) for problems receiving needed medical care, and 2.62 (95% CI 1.46, 4.67) for seeing a specialist. Our survey of older minority adults in South Los Angeles found increased delays in access to care for needed medical services after the closure of Martin Luther King, Jr. Hospital. As health care reform unfolds, monitoring for changes in access to care that may result from new policies will be important to address future disparities, particularly for vulnerable populations.

  14. Opening up closure. Semiotics across scales

    PubMed

    Lemke

    2000-01-01

    The dynamic emergence of new levels of organization in complex systems is related to the semiotic reorganization of discrete/continuous variety at the level below as continuous/discrete meaning for the level above. In this view both the semiotic and the dynamic closure of system levels is reopened to allow the development and evolution of greater complexity.

  15. 10 CFR 63.113 - Performance objectives for the geologic repository after permanent closure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Performance objectives for the geologic repository after permanent closure. 63.113 Section 63.113 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH... and an engineered barrier system. (b) The engineered barrier system must be designed so that, working...

  16. 10 CFR 63.113 - Performance objectives for the geologic repository after permanent closure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Performance objectives for the geologic repository after permanent closure. 63.113 Section 63.113 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH... and an engineered barrier system. (b) The engineered barrier system must be designed so that, working...

  17. 10 CFR 63.113 - Performance objectives for the geologic repository after permanent closure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Performance objectives for the geologic repository after permanent closure. 63.113 Section 63.113 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH... and an engineered barrier system. (b) The engineered barrier system must be designed so that, working...

  18. 10 CFR 63.113 - Performance objectives for the geologic repository after permanent closure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Performance objectives for the geologic repository after permanent closure. 63.113 Section 63.113 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH... and an engineered barrier system. (b) The engineered barrier system must be designed so that, working...

  19. Mass exchange in an experimental new-generation life support system model based on biological regeneration of environment.

    PubMed

    Tikhomirov, A A; Ushakova, S A; Manukovsky, N S; Lisovsky, G M; Kudenko, Yu A; Kovalev, V S; Gubanov, V G; Barkhatov, Yu V; Gribovskaya, I V; Zolotukhin, I G; Gros, J B; Lasseur, Ch

    2003-01-01

    An experimental model of a biological life support system was used to evaluate qualitative and quantitative parameters of the internal mass exchange. The photosynthesizing unit included the higher plant component (wheat and radish), and the heterotrophic unit consisted of a soil-like substrate, California worms, mushrooms and microbial microflora. The gas mass exchange involved evolution of oxygen by the photosynthesizing component and its uptake by the heterotroph component along with the formation and maintaining of the SLS structure, growth of mushrooms and California worms, human respiration, and some other processes. Human presence in the system in the form of "virtual human" that at regular intervals took part in the respirative gas exchange during the experiment. Experimental data demonstrated good oxygen/carbon dioxide balance, and the closure of the cycles of these gases was almost complete. The water cycle was nearly 100% closed. The main components in the water mass exchange were transpiration water and the watering solution with mineral elements. Human consumption of the edible plant biomass (grains and roots) was simulated by processing these products by a unique physicochemical method of oxidizing them to inorganic mineral compounds, which were then returned into the system and fully assimilated by the plants. The oxidation was achieved by "wet combustion" of organic biomass, using hydrogen peroxide following a special procedure, which does not require high temperature and pressure. Hydrogen peroxide is produced from the water inside the system. The closure of the cycle was estimated for individual elements and compounds. Stoichiometric proportions are given for the main components included in the experimental model of the system. Approaches to the mathematical modeling of the cycling processes are discussed, using the data of the experimental model. Nitrogen, as a representative of biogenic elements, shows an almost 100% closure of the cycle inside the system. The proposed experimental model of a biological system is discussed as a candidate for potential application in the investigations aimed at creating ecosystems with largely closed cycles of the internal mass exchange. The formation and maintenance of sustainable cycling of vitally important chemical elements and compounds in biological life support systems (BLSS) is an extremely pressing problem. To attain the stable functioning of biological life support systems (BLSS) and to maintain a high degree of closure of material cycles in than, it is essential to understand the character of mass exchange processes and stoichiometnc proportions of the initial and synthesized components of the system. c2003 COSPAR. Published by Elsevier Science Ltd. All rights reserved.

  20. Unilateral angle-closure glaucoma with ciliochoroidal effusion after the consumption of cannabis: a case report.

    PubMed

    Hanna, Rana; Tiosano, Beatrice; Dbayat, Noora; Gaton, Dan

    2014-01-01

    A 35-year-old male patient, diagnosed with acute angle-closure glaucoma, did not improve despite intensive treatment with antiglaucoma medications. Ultrasound biomicroscopy revealed a ciliochoroidal effusion. Due to his past history of drug abuse, a urine test was analyzed and found to be positive for cannabis. After topical cycloplegia and oral steroid therapy, his symptoms improved substantially. The present case highlights the role of ultrasound biomicroscopy in evaluating patients with acute angle-closure glaucoma and the role of cannabis abuse in the development of ciliochoroidal effusion.

  1. Evaluation of a novel technique for wound closure using a barbed suture.

    PubMed

    Murtha, Amy P; Kaplan, Andrew L; Paglia, Michael J; Mills, Benjie B; Feldstein, Michael L; Ruff, Gregory L

    2006-05-01

    Suture knots present several disadvantages in wound closure, because they are tedious to tie and place ischemic demands on tissue. Bulky knots may be a nidus for infection, and they may extrude through skin weeks after surgery. Needle manipulations during knot-tying predispose the surgeon to glove perforation. A barbed suture was developed that is self-anchoring, requiring no knots or slack management for wound closure. The elimination of knot tying may have advantages over conventional wound closure methods. This prospective, randomized, controlled trial was designed to show that the use of barbed suture in dermal closure of the Pfannenstiel incision during nonemergent cesarean delivery surgery produces scar cosmesis at 5 weeks that is no worse than that observed with conventional closure using 3-0 polydioxanone suture. Cosmesis was assessed by review of postoperative photographs by a blinded, independent plastic surgeon using the modified Hollander cosmesis score. Secondary endpoints included infection, dehiscence, pain, closure time, and other adverse events. The study enrolled 195 patients, of whom 188 were eligible for analysis. Cosmesis scores did not significantly differ between the barbed suture group and the control group. Rates of infection, dehiscence, and other adverse events did not significantly differ between the two groups. Closure time and pain scores were comparable between the groups. The barbed suture represents an innovative option for wound closure. With a cosmesis and safety profile that is similar to that of conventional suture technique, it avoids the drawbacks inherent to suture knots.

  2. Spontaneous closure of traumatic macular hole

    PubMed Central

    Sanjay, Srinivasan; Yeo, Tun Kuan; Au Eong, Kah-Guan

    2012-01-01

    Macular hole formation is a well-known complication following ocular trauma. Less commonly recognised is the spontaneous closure of such holes. A 27-year-old man presented with a history of blunt trauma to his left eye. Eye evaluation showed conjunctival laceration, diffuse retinal oedema and multiple retinal haemorrhages in that eye. A month later, he developed a full thickness macular hole. Two months later, there was spontaneous complete closure of the full-thickness macular hole in the left eye as confirmed on optical coherence tomography. Spontaneous closure of hole is not uncommon. Observation for a period of up to 12 months is a reasonable management option. Macular hole surgery for traumatic macular holes may be delayed in such cases. PMID:23961017

  3. Effective time closures: quantifying the conservation benefits of input control for the Pacific chub mackerel fishery.

    PubMed

    Ichinokawa, Momoko; Okamura, Hiroshi; Watanabe, Chikako; Kawabata, Atsushi; Oozeki, Yoshioki

    2015-09-01

    Restricting human access to a specific wildlife species, community, or ecosystem, i.e., input control, is one of the most popular tools to control human impacts for natural resource management and wildlife conservation. However, quantitative evaluations of input control are generally difficult, because it is unclear how much human impacts can actually be reduced by the control. We present a model framework to quantify the effectiveness of input control using day closures to reduce actual fishing impact by considering the observed fishery dynamics. The model framework was applied to the management of the Pacific stock of the chub mackerel (Scomber japonicus) fishery, in which fishing was suspended for one day following any day when the total mackerel catch exceeded a threshold level. We evaluated the management measure according to the following steps: (1) we fitted the daily observed catch and fishing effort data to a generalized linear model (GLM) or generalized autoregressive state-space model (GASSM), (2) we conducted population dynamics simulations based on annual catches randomly generated from the parameters estimated in the first step, (3) we quantified the effectiveness of day closures by comparing the results of two simulation scenarios with and without day closures, and (4) we conducted additional simulations based on different sets of explanatory variables and statistical models (sensitivity analysis). In the first step, we found that the GASSM explained the observed data far better than the simple GLM. The model parameterized with the estimates from the GASSM demonstrated that the day closures implemented from 2004 to 2009 would have decreased exploitation fractions by ~10% every year and increased the 2009 stock biomass by 37-46% (median), relative to the values without day closures. The sensitivity analysis revealed that the effectiveness of day closures was particularly influenced by autoregressive processes in the fishery data and by positive relationships between fishing effort and total biomass. Those results indicated the importance of human behavioral dynamics under input control in quantifying the conservation benefit of natural resource management and the applicability of our model framework to the evaluation of the input controls that are actually implemented.

  4. Achieving Closure for Bioregenerative Life Support Systems: Engineering and Ecological Challenges, Research Opportunities

    NASA Astrophysics Data System (ADS)

    Dempster, William; Allen, John P.

    Closed systems are desirable for a number of purposes: space life support systems where precious life-supporting resources need to be kept inside; biospheric systems; where global ecological pro-cesses can be studied in great detail and testbeds where research topics requiring isolation from the outside (e.g. genetically modified organisms; radioisotopes) can be studied in isolation from the outside environment and where their ecological interactions and fluxes can be studied. But to achieve and maintain closure raises both engineering and ecological challenges. Engineering challenges include methods of achieving closure for structures of different materials, and devel-oping methods of allowing energy (for heating and cooling) and information transfer through the materially closed structure. Methods of calculating degree of closure include measuring degradation rates of inert trace gases introduced into the system. An allied problem is devel-oping means of locating where leaks are located so that they may be repaired and degree of closure maintained. Once closure is achieved, methods of dealing with the pressure differen-tials between inside and outside are needed: from inflatable structures which might adjust to the pressure difference to variable volume chambers attached to the life systems component. These issues are illustrated through the engineering employed at Biosphere 2, the Biosphere 2 Test Module and the Laboratory Biosphere and a discussion of methods used by other closed ecological system facility engineers. Ecological challenges include being able to handle faster cycling rates and accentuated daily and seasonal fluxes of critical life elements such as carbon dioxide, oxygen, water, macro-and mico-nutrients. The problems of achieving sustainability in closed systems for life support include how to handle atmospheric dynamics including trace gases, producing a complete human diet and recycling nutrients and maintaining soil fertility, healthy air and water and preventing the loss of crucial elements from active circulation. In biospheric facilities the challenge is also to produce analogue to natural biomes and ecosys-tems, studying processes of self-organization and adaptation in systems that allow specification or determination of state variables and cycles which may be followed through all interactions from atmosphere to soils.

  5. Complexity VIII. Ontology of closure in complex systems: The C* hypothesis and the O° notation

    NASA Astrophysics Data System (ADS)

    Chandler, Jerry LR

    1999-03-01

    Closure is a common characteristic of mathematical, natural and socio-cultural systems. Whether one is describing a graph, a molecule, a cell, a human, or a nation state, closure is implicitly understood. An objective of this paper is to continue a construction of a systematic framework for closure which is sufficient for future quantitative transdisciplinary investigations. A further objective is to extend the Birkhoff-von Neumann criterion for quantum systems to complex natural objects. The C* hypothesis is being constructed to be consistent with algebraic category theory (Ehresmann and Vanbremeersch, 1987, 1997, Chandler, 1990, 1991, Chandler, Ehresmann and Vanbremeersch, 1996). Five aspects of closure will be used to construct a framework for categories of complex systems: 1. Truth functions in mathematics and the natural sciences 2. Systematic descriptions in the mks and O° notations 3. Organizational structures in hierarchical scientific languages 4. Transitive organizational pathways in the causal structures of complex behaviors 5. Composing additive, multiplicative and exponential operations in complex systems Truth functions can be formal or objective or subjective, depending on the complexity of the system and on our capability to represent the fine structure of the system symbolically, observationally or descriptively. "Complete" material representations of the fine structure of a system may allow truth functions to be created over sets of one to one correspondences. Less complete descriptions can support less stringent truth functions based on coherence or subjective judgments. The role of human values in creating and perpetuating truth functions can be placed in context of the degree of fine structure in the system's description. The organization of complex systems are hypothesized to be categorizable into degrees relative to one another, thereby creating an ordering relationship. This ordering relationship is denoted by the symbols: O°1, O°2,O°3... For example, for material systems, an ordering relation such as particles, atoms, molecules, cells, tissues, organs, individuals and social groups might be assigned to classify observations for medical purposes. The C* hypothesis asserts that any complex system can be described in terms of four enumerable concepts: closure, conformation, concatenation and cyclicity. Mappings between objects are constructed within a notation for organization. Causality is organized within C* as pathways of relationships in time. The notation of organizational degrees is used to distinguish a directionality for causality: 1. bottom-up (energy flows) 2. top-down (control processes or dominating variables), 3. outside — inward (ecoment on organism) and 4. inside — outward (organism on ecoment). Closures are asserted to emerge from evolutionary cooperation. It is asserted that truth functions emerged from the necessity of an organism to identify ecoments where life can prosper. For example, basic truth functions of mathematics (operations of addition, multiplication and exponentiation) are made operationally consistent within the biochemical operations of sustaining exponential cellular growth. These fundamental mathematical functions can provide a logical basis (in conjunction with conservation rules) for a construction of complex material categories at higher degrees of organization. It is remarked that these simple functions suggests a biochemical origin for the intuitionistic philosophy of mathematics. The emergence and success of mathematics is conjectured to result from the need to acquire a consistent basis for communication among individuals seeking to cooperate socially. This suggests a cultural closure over a collection of individual closures.

  6. Common side closure type, but not stapler brand or oversewing, influences side-to-side anastomotic leak rates.

    PubMed

    Fleetwood, V A; Gross, K N; Alex, G C; Cortina, C S; Smolevitz, J B; Sarvepalli, S; Bakhsh, S R; Poirier, J; Myers, J A; Singer, M A; Orkin, B A

    2017-03-01

    Anastomotic leak (AL) increases costs and cancer recurrence. Studies show decreased AL with side-to-side stapled anastomosis (SSA), but none identify risk factors within SSAs. We hypothesized that stapler characteristics and closure technique of the common enterotomy affect AL rates. Retrospective review of bowel SSAs was performed. Data included stapler brand, staple line oversewing, and closure method (handsewn, HC; linear stapler [Barcelona technique], BT; transverse stapler, TX). Primary endpoint was AL. Statistical analysis included Fisher's test and logistic regression. 463 patients were identified, 58.5% BT, 21.2% HC, and 20.3% TX. Covidien staplers comprised 74.9%, Ethicon 18.1%. There were no differences between stapler types (Covidien 5.8%, Ethicon 6.0%). However, AL rates varied by common side closure (BT 3.7% vs. TX 10.6%, p = 0.017), remaining significant on multivariate analysis. Closure method of the common side impacts AL rates. Barcelona technique has fewer leaks than transverse stapled closure. Further prospective evaluation is recommended. Copyright © 2017. Published by Elsevier Inc.

  7. Evaluation of muscle hyperactivity of the grimacing muscles by unilateral tight eyelid closure and stapedius muscle tone.

    PubMed

    Shiba, Masato; Matsuo, Kiyoshi; Ban, Ryokuya; Nagai, Fumio

    2012-10-01

    Muscle hyperactivity of grimacing muscles, including the orbicularis oculi and corrugator supercilii muscles that cause crow's feet and a glabellar frown line with ageing, cannot be accurately evaluated by surface observation. In 71 subjects, this study investigated the extent to which grimacing muscles are innervated by the bilateral motor cortices, whether the corticofacial projection to the grimacing muscles affects the facially innervated stapedius muscle tone by measuring static compliance of the tympanic membrane, and whether unilateral tight eyelid closure with contraction of the grimacing muscles changes static compliance. Unilateral tight eyelid closure and its subsequent change in the contralateral vertical medial eyebrow position revealed that motor neurons of the orbicularis oculi and corrugator supercilii muscles were innervated by the bilateral motor cortices with weak-to-strong contralateral dominance. The orbicularis oculi, corrugator supercilii, and stapedius muscles innervated by the bilateral motor cortices had increased muscle hyperactivity, which lowered the vertical medial eyebrow position and decreased the static compliance of the tympanic membrane more than those innervated by the unilateral motor cortex. Unilateral enhanced tight eyelid closure with contraction of the grimacing muscles in certain subjects ipsilaterally decreased the static compliance with increased contraction of the stapedius muscle, which probably occurs to immobilise the tympanic membrane and protect the inner ear from loud sound. Evaluation of unilateral tight eyelid closure and the subsequent change in the contralateral vertical medial eyebrow position as well as a measurement of the static compliance for the stapedius muscle tone has revealed muscle hyperactivity of grimacing muscles.

  8. Model-Based Comprehensive Analysis of School Closure Policies for Mitigating Influenza Epidemics and Pandemics

    PubMed Central

    Fumanelli, Laura; Ajelli, Marco; Merler, Stefano; Ferguson, Neil M.; Cauchemez, Simon

    2016-01-01

    School closure policies are among the non-pharmaceutical measures taken into consideration to mitigate influenza epidemics and pandemics spread. However, a systematic review of the effectiveness of alternative closure policies has yet to emerge. Here we perform a model-based analysis of four types of school closure, ranging from the nationwide closure of all schools at the same time to reactive gradual closure, starting from class-by-class, then grades and finally the whole school. We consider policies based on triggers that are feasible to monitor, such as school absenteeism and national ILI surveillance system. We found that, under specific constraints on the average number of weeks lost per student, reactive school-by-school, gradual, and county-wide closure give comparable outcomes in terms of optimal infection attack rate reduction, peak incidence reduction or peak delay. Optimal implementations generally require short closures of one week each; this duration is long enough to break the transmission chain without leading to unnecessarily long periods of class interruption. Moreover, we found that gradual and county closures may be slightly more easily applicable in practice as they are less sensitive to the value of the excess absenteeism threshold triggering the start of the intervention. These findings suggest that policy makers could consider school closure policies more diffusely as response strategy to influenza epidemics and pandemics, and the fact that some countries already have some experience of gradual or regional closures for seasonal influenza outbreaks demonstrates that logistic and feasibility challenges of school closure strategies can be to some extent overcome. PMID:26796333

  9. Model-Based Comprehensive Analysis of School Closure Policies for Mitigating Influenza Epidemics and Pandemics.

    PubMed

    Fumanelli, Laura; Ajelli, Marco; Merler, Stefano; Ferguson, Neil M; Cauchemez, Simon

    2016-01-01

    School closure policies are among the non-pharmaceutical measures taken into consideration to mitigate influenza epidemics and pandemics spread. However, a systematic review of the effectiveness of alternative closure policies has yet to emerge. Here we perform a model-based analysis of four types of school closure, ranging from the nationwide closure of all schools at the same time to reactive gradual closure, starting from class-by-class, then grades and finally the whole school. We consider policies based on triggers that are feasible to monitor, such as school absenteeism and national ILI surveillance system. We found that, under specific constraints on the average number of weeks lost per student, reactive school-by-school, gradual, and county-wide closure give comparable outcomes in terms of optimal infection attack rate reduction, peak incidence reduction or peak delay. Optimal implementations generally require short closures of one week each; this duration is long enough to break the transmission chain without leading to unnecessarily long periods of class interruption. Moreover, we found that gradual and county closures may be slightly more easily applicable in practice as they are less sensitive to the value of the excess absenteeism threshold triggering the start of the intervention. These findings suggest that policy makers could consider school closure policies more diffusely as response strategy to influenza epidemics and pandemics, and the fact that some countries already have some experience of gradual or regional closures for seasonal influenza outbreaks demonstrates that logistic and feasibility challenges of school closure strategies can be to some extent overcome.

  10. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    PubMed

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing has recently gained industry attention due to increased regulatory agency scrutiny regarding the analytical rigor of container closure integrity testing methods and expectations to use container closure integrity testing in lieu of sterility tests in stability programs. Methylene blue dye is often used for dye ingress testing of container closure integrity, but we found it unsuitable for reliable detection of small breaches in prefilled syringes of drug product. This work describes the suitability and advantages of using a fluorescent dye and spectroscopic detection for a robust, sensitive, and quality control-friendly container closure integrity testing method for prefilled syringes. © PDA, Inc. 2016.

  11. iLid: Low-power Sensing of Fatigue and Drowsiness Measures on a Computational Eyeglass

    PubMed Central

    ROSTAMINIA, SOHA; MAYBERRY, ADDISON; GANESAN, DEEPAK; MARLIN, BENJAMIN; GUMMESON, JEREMY

    2018-01-01

    The ability to monitor eye closures and blink patterns has long been known to enable accurate assessment of fatigue and drowsiness in individuals. Many measures of the eye are known to be correlated with fatigue including coarse-grained measures like the rate of blinks as well as fine-grained measures like the duration of blinks and the extent of eye closures. Despite a plethora of research validating these measures, we lack wearable devices that can continually and reliably monitor them in the natural environment. In this work, we present a low-power system, iLid, that can continually sense fine-grained measures such as blink duration and Percentage of Eye Closures (PERCLOS) at high frame rates of 100fps. We present a complete solution including design of the sensing, signal processing, and machine learning pipeline; implementation on a prototype computational eyeglass platform; and extensive evaluation under many conditions including illumination changes, eyeglass shifts, and mobility. Our results are very encouraging, showing that we can detect blinks, blink duration, eyelid location, and fatigue-related metrics such as PERCLOS with less than a few percent error. PMID:29417956

  12. Leg ulcer treatment outcomes with new ovine collagen extracellular matrix dressing: a retrospective case series.

    PubMed

    Bohn, Gregory A; Gass, Kimberly

    2014-10-01

    The purpose of this study was to describe the rate of closure observed in venous leg ulcers during treatment with ovine collagen extracellular matrix dressings and compression. Fourteen patients with 23 wounds were retrospectively evaluated with respect to healing rates, time to closure, and weekly facility charge fees.

  13. An Evaluation and Analysis of Past Landfill Closures in Puerto Rico as Guidance for Current and Future Closures

    EPA Science Inventory

    The island of Puerto Rico has faced several challenges related to the issue of closed landfills – historically, many municipal landfills in Puerto Rico were not closed properly or abandoned, while others were closed in accordance with applicable rules but have sustained physical ...

  14. Engineering study for closure of 209E facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brevick, C.H.; Heys, W.H.; Johnson, E.D.

    1997-07-07

    This document is an engineering study for evaluating alternatives to determine the most cost effective closure plan for the 209E Facility, Critical Mass Laboratory. This laboratory is located in the 200 East Area of the Hanford Site and contains a Critical Assembly Room and a Mix room were criticality experiments were once performed.

  15. EVALUATION OF MASS FLUX TO AND FROM GROUND WATER USING A VERTICAL FLUX MODEL (VFLUX): APPLICATION TO THE SOIL VACUUM EXTRACTION CLOSURE PROBLEM

    EPA Science Inventory

    Site closure for soil vacuum extraction (SVE) application typically requires attainment of specified soil concentration standards based on the premise that mass flux from the vadose zone to ground water not result in levels exceeding maximum contaminant levels (MCLSs). Unfortuna...

  16. Angle closure in younger patients.

    PubMed Central

    Chang, Brian M; Liebmann, Jeffrey M; Ritch, Robert

    2002-01-01

    PURPOSE: Angle-closure glaucoma is rare in children and young adults. Only scattered cases associated with specific clinical entities have been reported. We evaluated the findings in patients in our database aged 40 or younger with angle closure. METHODS: Our database was searched for patients with angle closure who were 40 years old or younger. Data recorded included age at initial consultation; age at the time of diagnosis; gender; results of slit-lamp examination, gonioscopy, and ultrasound biomicroscopy (from 1993 onward); clinical diagnosis; and therapy. Patients with previous incisional surgery were excluded, as were patients with anterior chamber proliferative mechanisms leading to angle closure. RESULTS: Sixty-seven patients (49 females, 18 males) met entry criteria. Mean age (+/- SD) at the time of consultation was 34.4 +/- 9.4 years (range, 3-68 years). Diagnoses included plateau iris syndrome (35 patients), iridociliary cysts (8 patients), retinopathy of prematurity (7 patients), uveitis (5 patients), isolated nanophthalmos (3 patients), relative pupillary block (2 patients), Weill-Marchesani syndrome (3 patients), and 1 patient each with Marfan syndrome, miotic-induced angle closure, persistent hyperplastic primary vitreous, and idiopathic lens subluxation. CONCLUSION: The etiology of angle closure in young persons is different from that in the older population and is typically associated with structural or developmental ocular anomalies rather than relative pupillary block. Following laser iridotomy, these eyes should be monitored for recurrent angle closure and the need for additional laser or incisional surgical intervention. PMID:12545694

  17. [Velopharyngeal closure pattern and speech performance among submucous cleft palate patients].

    PubMed

    Heng, Yin; Chunli, Guo; Bing, Shi; Yang, Li; Jingtao, Li

    2017-06-01

    To characterize the velopharyngeal closure patterns and speech performance among submucous cleft palate patients. Patients with submucous cleft palate visiting the Department of Cleft Lip and Palate Surgery, West China Hospital of Stomatology, Sichuan University between 2008 and 2016 were reviewed. Outcomes of subjective speech evaluation including velopharyngeal function, consonant articulation, and objective nasopharyngeal endoscopy including the mobility of soft palate, pharyngeal walls were retrospectively analyzed. A total of 353 cases were retrieved in this study, among which 138 (39.09%) demonstrated velopharyngeal competence, 176 (49.86%) velopharyngeal incompetence, and 39 (11.05%) marginal velopharyngeal incompetence. A total of 268 cases were subjected to nasopharyngeal endoscopy examination, where 167 (62.31%) demonstrated circular closure pattern, 89 (33.21%) coronal pattern, and 12 (4.48%) sagittal pattern. Passavant's ridge existed in 45.51% (76/167) patients with circular closure and 13.48% (12/89) patients with coronal closure. Among the 353 patients included in this study, 137 (38.81%) presented normal articulation, 124 (35.13%) consonant elimination, 51 (14.45%) compensatory articulation, 36 (10.20%) consonant weakening, 25 (7.08%) consonant replacement, and 36 (10.20%) multiple articulation errors. Circular closure was the most prevalent velopharyngeal closure pattern among patients with submucous cleft palate, and high-pressure consonant deletion was the most common articulation abnormality. Articulation error occurred more frequently among patients with a low velopharyngeal closure rate.

  18. Reactor refueling containment system

    DOEpatents

    Gillett, J.E.; Meuschke, R.E.

    1995-05-02

    A method of refueling a nuclear reactor is disclosed whereby the drive mechanism is disengaged and removed by activating a jacking mechanism that raises the closure head. The area between the barrier plate and closure head is exhausted through the closure head penetrations. The closure head, upper drive mechanism, and bellows seal are lifted away and transported to a safe area. The barrier plate acts as the primary boundary and each drive and control rod penetration has an elastomer seal preventing excessive tritium gases from escaping. The individual instrumentation plugs are disengaged allowing the corresponding fuel assembly to be sealed and replaced. 2 figs.

  19. Reactor refueling containment system

    DOEpatents

    Gillett, James E.; Meuschke, Robert E.

    1995-01-01

    A method of refueling a nuclear reactor whereby the drive mechanism is disengaged and removed by activating a jacking mechanism that raises the closure head. The area between the barrier plate and closure head is exhausted through the closure head penetrations. The closure head, upper drive mechanism, and bellows seal are lifted away and transported to a safe area. The barrier plate acts as the primary boundary and each drive and control rod penetration has an elastomer seal preventing excessive tritium gases from escaping. The individual instrumentation plugs are disengaged allowing the corresponding fuel assembly to be sealed and replaced.

  20. A clinical review of infected wound treatment with Vacuum Assisted Closure (V.A.C.) therapy: experience and case series.

    PubMed

    Gabriel, Allen; Shores, Jaimie; Bernstein, Brent; de Leon, Jean; Kamepalli, Ravi; Wolvos, Tom; Baharestani, Mona M; Gupta, Subhas

    2009-10-01

    Over the last decade Vacuum Assisted Closure((R)) (KCI Licensing, Inc., San Antonio, TX) has been established as an effective wound care modality for managing complex acute and chronic wounds. The therapy has been widely adopted by many institutions to treat a variety of wound types. Increasingly, the therapy is being used to manage infected and critically colonized, difficult-to-treat wounds. This growing interest coupled with practitioner uncertainty in using the therapy in the presence of infection prompted the convening of an interprofessional expert advisory panel to determine appropriate use of the different modalities of negative pressure wound therapy (NPWT) as delivered by V.A.C.((R)) Therapy and V.A.C. Instill((R)) with either GranuFoam() or GranuFoam Silver() Dressings. The panel reviewed infected wound treatment methods within the context of evidence-based medicine coupled with experiential insight using V.A.C.((R)) Therapy Systems to manage a variety of infected wounds. The primary objectives of the panel were 1) to exchange state-of-practice evidence, 2) to review and evaluate the strength of existing data, and 3) to develop practice recommendations based on published evidence and clinical experience regarding use of the V.A.C.((R)) Therapy Systems in infected wounds. These recommendations are meant to identify which infected wounds will benefit from the most appropriate V.A.C.((R)) Therapy System modality and provide an infected wound treatment algorithm that may lead to a better understanding of optimal treatment strategies.

  1. Associations with duration of compensation following whiplash sustained in a motor vehicle crash.

    PubMed

    Casey, Petrina P; Feyer, Anne Marie; Cameron, Ian D

    2015-09-01

    Continued exposure to compensation systems has been reported as deleterious to the health of participants. Understanding the associations with time to claim closure could allow for targeted interventions aimed at minimising the time participants are exposed to the compensation system. To identify the associations of extended time receiving compensation benefits with the aim of developing a prognostic model that predicts time to claim closure. Prospective cohort study in people with whiplash associated disorder. Time to claim closure, in a privately underwritten fault based third party traffic crash insurance scheme in New South Wales, Australia. Cox proportional hazard regression modelling. Of the 246 participants, 25% remained in the compensation system longer than 24 months with 15% remaining longer than three years. Higher initial disability (Functional Rating Index≥25 at baseline) (HRR: 95% CI, 1.916: 1.324-2.774, p<0.001); and lower initial mental health as measured by SF-36 Mental Component Score (HRR: 95% CI, 0.973: 0.960-0.987, p<0.001) were significantly and independently associated with an increased time-to-claim closure. Shorter time to claim closure was associated with having no legal involvement (HRR: 95% CI, 1.911: 1.169-3.123, p=0.009); and, not having a prior claim for compensation (HRR: 95% CI, 1.523: 1.062-2.198, p=0.022). Health and insurance related factors are independently associated with time to claim closure. Both factors need to be considered by insurers in their assessment of complexity of claims. Interventions aimed at minimising the impact of these factors could reduce claimants' exposure to the compensation system. In turn insurers can potentially reduce claims duration and cost, while improving the health outcomes of claimants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Phase closure nulling: Theory and practice

    NASA Astrophysics Data System (ADS)

    Chelli, A.; Duvert, G.; Malbet, F.; Kern, P.

    2009-11-01

    We provide a complete theory of the phase closure of a binary system in which a small, feeble, and unresolved companion acts as a perturbing parameter on the spatial frequency spectrum of a dominant, bright, resolved source. We demonstrate that the influence of the companion can be measured with precision by measuring the phase closure of the system near the nulls of the primary visibility function. In these regions of phase closure nulling, frequency intervals always exist where the phase closure signature of the companion is larger than any systematic error and can thus be measured. We show that this technique allows retrieval of many astrophysically relevant properties of faint and close companions such as flux, position, and in favorable cases, spectrum. As a proof of concept, using the AMBER/VLTI instrument with 3 auxiliary telescopes of 1.8 m and only 15 minutes of on-sky integration, we detected the five magnitudes fainter companion of HD 59717 at only 3.5 stellar radii distance from the primary. This is one of the highest contrast detected by interferometry between a companion and its parent star. We conclude by a rapid study of the potentialities of phase closure nulling observations with current interferometers and explore the requirements for a new type of dedicated instrument.

  3. Effectiveness of Recombinant Human Growth Hormone for Pharyngocutaneous Fistula Closure

    PubMed Central

    Sari, Murat; Midi, Ahmet; Yumusakhuylu, Ali Cemal; Findik, Ozan; Binnetoglu, Adem

    2015-01-01

    Objectives In laryngeal cancer, which comprises 25% of head and neck cancer, chemotherapy has come into prominence with the increase in organ-protective treatments. With such treatment, salvage surgery has increased following recurrence; the incidence of pharyngocutaneous fistula has also increased in both respiratory and digestive system surgery. We investigated the effects of recombinant human growth hormone on pharyngocutaneous fistula closure in Sprague-Dawley rats, based on an increase in amino acid uptake and protein synthesis for wound healing, an increase in mitogenesis, and enhancement of collagen formation by recombinant human growth hormone. Methods This study was experimental animal study. Forty Sprague-Dawley rats were separated into two groups, and pharyngoesophagotomy was performed. The pharyngoesophagotomy was sutured with vicryl in both groups. Rats in group 1 (control group) received no treatment, while those in group 2 were administered a subcutaneous injection of recombinant human growth hormone daily. On day 14, the pharynx, larynx, and upper oesophagus were excised and examined microscopically. Results Pharyngocutaneous fistula exhibited better closure macroscopically in the recombinant human growth hormone group. There was a significant difference in collagen formation and epithelisation in the recombinant human growth hormone group compared to the control group. Conclusion This study is believed to be the first in which the effect of recombinant human growth hormone on pharyngocutaneous fistula closure was evaluated, and the findings suggest the potential of use of growth hormone for treatment of pharyngocutaneous fistula. PMID:26622960

  4. Photodynamic therapy with PhotoPoint photosensitiser MV6401, indium chloride methyl pyropheophorbide, achieves selective closure of rat corneal neovascularisation and rabbit choriocapillaris

    PubMed Central

    Ciulla, T A; Criswell, M H; Snyder, W J; Small, W

    2005-01-01

    Aim: The new photosensitiser PhotoPoint MV6401, indium chloride methyl pyropheophorbide, was assessed as a possible ocular photodynamic therapy agent in a rat model of experimentally induced corneal neovascularisation and in choriocapillaris closure in the rabbit. Optimal drug and light activation parameters were determined. Methods: MV6401 (Miravant Pharmaceuticals, Inc, Santa Barbara, CA, USA) was activated at 664 nm using a DD3-0665 (Miravant Systems Inc) 0.5 W diode laser. Corneal neovascularisation in rats was induced using an N-heptanol technique. The evaluated drug dosages, light dosages, and post-injection activation times ranged from 0.01–0.1 μmol/kg, 5–25 J/cm2, and 10–60 minutes, respectively. The efficacy of MV6401 on normal choriocapillaris and choroidal vessels was evaluated in rabbits with indirect ophthalmoscopy, fundus photography, fluorescein angiography, and histology. In rabbits, the evaluated drug dosages, light dosages, and post-injection activation times ranged from 0.025–0.25 μmol/kg, 3.3–20 J/cm2, and 10 minutes, respectively. Results: In the rat corneal neovascularisation model, an optimal intravenous drug dosage of 0.075 μmol/kg was activated by a 20 J/cm2 light dose at 10 minutes after drug administration, the results of which demonstrated early evidence of efficacy in ocular neovascularisation. In rabbits, closure of the normal choriocapillaris was selectively achieved at a drug dosage of 0.15 μmol/kg using light doses from 3.3 to 20 J/cm2. Conclusion: PhotoPoint MV6401 is a potent photosensitiser that demonstrates both efficacy and selectivity in experimental ocular models. PMID:15615758

  5. Photodynamic therapy with PhotoPoint photosensitiser MV6401, indium chloride methyl pyropheophorbide, achieves selective closure of rat corneal neovascularisation and rabbit choriocapillaris.

    PubMed

    Ciulla, T A; Criswell, M H; Snyder, W J; Small, W

    2005-01-01

    The new photosensitiser PhotoPoint MV6401, indium chloride methyl pyropheophorbide, was assessed as a possible ocular photodynamic therapy agent in a rat model of experimentally induced corneal neovascularisation and in choriocapillaris closure in the rabbit. Optimal drug and light activation parameters were determined. MV6401 (Miravant Pharmaceuticals, Inc, Santa Barbara, CA, USA) was activated at 664 nm using a DD3-0665 (Miravant Systems Inc) 0.5 W diode laser. Corneal neovascularisation in rats was induced using an N-heptanol technique. The evaluated drug dosages, light dosages, and post-injection activation times ranged from 0.01-0.1 micromol/kg, 5-25 J/cm(2), and 10-60 minutes, respectively. The efficacy of MV6401 on normal choriocapillaris and choroidal vessels was evaluated in rabbits with indirect ophthalmoscopy, fundus photography, fluorescein angiography, and histology. In rabbits, the evaluated drug dosages, light dosages, and post-injection activation times ranged from 0.025-0.25 micromol/kg, 3.3-20 J/cm(2), and 10 minutes, respectively. In the rat corneal neovascularisation model, an optimal intravenous drug dosage of 0.075 micromol/kg was activated by a 20 J/cm(2) light dose at 10 minutes after drug administration, the results of which demonstrated early evidence of efficacy in ocular neovascularisation. In rabbits, closure of the normal choriocapillaris was selectively achieved at a drug dosage of 0.15 micromol/kg using light doses from 3.3 to 20 J/cm(2). PhotoPoint MV6401 is a potent photosensitiser that demonstrates both efficacy and selectivity in experimental ocular models.

  6. Pure natural orifice transluminal endoscopic surgery (NOTES) with ultrasonography-guided transgastric access and over-the-scope-clip closure: a porcine feasibility and survival study.

    PubMed

    Donatsky, Anders Meller; Andersen, Luise; Nielsen, Ole Lerberg; Holzknecht, Barbara Juliane; Vilmann, Peter; Meisner, Søren; Jørgensen, Lars Nannestad; Rosenberg, Jacob

    2012-07-01

    Most natural orifice transluminal endoscopic surgery (NOTES) procedures to date rely on the hybrid technique with simultaneous laparoscopic access to protect against access-related complications and to achieve adequate triangulation for dissection. This is done at the cost of the potential benefits of this new minimally invasive technique. This study aimed to evaluate the feasibility and safety of a transgastric (TG) pure-NOTES procedure in a diagnostic setting. A TG pure-NOTES procedure with endoscopic ultrasonograpy (EUS)-guided access and over-the-scope-clip (OTSC) closure was performed for 10 pigs in a survival and feasibility study. A full macroscopic necropsy with subsequent histologic evaluation was performed on postoperative day (POD) 14. The outcome parameters were uncomplicated follow-up assessment, survival, intraoperative complications, intraabdominal pathology, macroscopic full-thickness closure, and histology-proven full-thickness healing of the gastrotomy. An uncomplicated postoperative course was reported for 9 of the 10 pigs, and survival was reported for all 10 pigs. For all the pigs, EUS-guided access was performed successfully with a median duration of 25 min (range, 12-62 min) and without intraoperative complications or access-related lesions at necropsy. An OTSC closure was achieved with a median duration of 11 min (range, 3-28 min). The OTSC provided immediate closure, but according to the authors' definition of a full-thickness healing evaluated by histologic examination, this was not achieved in any of the cases. Although all the animals survived until POD 14, intraabdominal chronic abscesses were present in 3 of the 10 pigs at necropsy. The EUS-guided TG access proved to be feasible without access-related complications. Although OTSC provided an immediate closure, the histopathology raised concerns regarding the risk of perforation. Together with the high risk of intraabdominal infection, TG pure-NOTES is not yet ready for routine clinical practice.

  7. Multivariate moment closure techniques for stochastic kinetic models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lakatos, Eszter, E-mail: e.lakatos13@imperial.ac.uk; Ale, Angelique; Kirk, Paul D. W.

    2015-09-07

    Stochastic effects dominate many chemical and biochemical processes. Their analysis, however, can be computationally prohibitively expensive and a range of approximation schemes have been proposed to lighten the computational burden. These, notably the increasingly popular linear noise approximation and the more general moment expansion methods, perform well for many dynamical regimes, especially linear systems. At higher levels of nonlinearity, it comes to an interplay between the nonlinearities and the stochastic dynamics, which is much harder to capture correctly by such approximations to the true stochastic processes. Moment-closure approaches promise to address this problem by capturing higher-order terms of the temporallymore » evolving probability distribution. Here, we develop a set of multivariate moment-closures that allows us to describe the stochastic dynamics of nonlinear systems. Multivariate closure captures the way that correlations between different molecular species, induced by the reaction dynamics, interact with stochastic effects. We use multivariate Gaussian, gamma, and lognormal closure and illustrate their use in the context of two models that have proved challenging to the previous attempts at approximating stochastic dynamics: oscillations in p53 and Hes1. In addition, we consider a larger system, Erk-mediated mitogen-activated protein kinases signalling, where conventional stochastic simulation approaches incur unacceptably high computational costs.« less

  8. Framework for culturally competent decisionmaking in child welfare.

    PubMed

    Cohen, Elena P

    2003-01-01

    This article provides a framework to understand the cultural, social, political, and economic factors that affect decisionmaking when working with ethnically and racially diverse families in the child welfare system. The article describes external factors affecting the decisionmaking process, including community environment, agency structure, and family characteristics. It then reviews the core stages of the casework process, describing key decisions during intake, assessment, service planning, implementation, evaluation, and closure. Although the framework is based on casework process in the child welfare system, it can be adapted to other child-serving systems, including education, mental health, and juvenile justice.

  9. Alterations of papilla dimensions after orthodontic closure of the maxillary midline diastema: a retrospective longitudinal study.

    PubMed

    Jeong, Jin-Seok; Lee, Seung-Youp; Chang, Moontaek

    2016-06-01

    The aim of this study was to evaluate alterations of papilla dimensions after orthodontic closure of the diastema between maxillary central incisors. Sixty patients who had a visible diastema between maxillary central incisors that had been closed by orthodontic approximation were selected for this study. Various papilla dimensions were assessed on clinical photographs and study models before the orthodontic treatment and at the follow-up examination after closure of the diastema. Influences of the variables assessed before orthodontic treatment on the alterations of papilla height (PH) and papilla base thickness (PBT) were evaluated by univariate regression analysis. To analyze potential influences of the 3-dimensional papilla dimensions before orthodontic treatment on the alterations of PH and PBT, a multiple regression model was formulated including the 3-dimensional papilla dimensions as predictor variables. On average, PH decreased by 0.80 mm and PBT increased after orthodontic closure of the diastema (P<0.01). Univariate regression analysis revealed that the PH (P=0.002) and PBT (P=0.047) before orthodontic treatment influenced the alteration of PH. With respect to the alteration of PBT, the diastema width (P=0.045) and PBT (P=0.000) were found to be influential factors. PBT before the orthodontic treatment significantly influenced the alteration of PBT in the multiple regression model. PH decreased but PBT increased after orthodontic closure of the diastema. The papilla dimensions before orthodontic treatment influenced the alterations of PH and PBT after closure of the diastema. The PBT increased more when the diastema width before the orthodontic treatment was larger.

  10. Impact of radiofrequency ablation for patients with varicose veins on the budget of the German statutory health insurance system

    PubMed Central

    2013-01-01

    Objectives In contrast to other countries, surgery still represents the common invasive treatment for varicose veins in Germany. However, radiofrequency ablation, e.g. ClosureFast, becomes more and more popular in other countries due to potential better results and reduced side effects. This treatment option may cause less follow-up costs and is a more convenient procedure for patients, which could justify an introduction in the statutory benefits catalogue. Therefore, we aim at calculating the budget impact of a general reimbursement of ClosureFast in Germany. Methods To assess the budget impact of including ClosureFast in the German statutory benefits catalogue, we developed a multi-cohort Markov model and compared the costs of a “World with ClosureFast” with a “World without ClosureFast” over a time horizon of five years. To address the uncertainty of input parameters, we conducted three different types of sensitivity analysis (one-way, scenario, probabilistic). Results In the Base Case scenario, the introduction of the ClosureFast system for the treatment of varicose veins saves costs of about 19.1 Mio. € over a time horizon of five years in Germany. However, the results scatter in the sensitivity analyses due to limited evidence of some key input parameters. Conclusions Results of the budget impact analysis indicate that a general reimbursement of ClosureFast has the potential to be cost-saving in the German Statutory Health Insurance. PMID:23551943

  11. Swatch Testing at Elevated Wind Speeds

    DTIC Science & Technology

    2014-07-17

    closures, for improved system performance. 15. SUBJECT TERMS Swatch Testing; Individual Protective Equipment (IPE) 16. SECURITY CLASSIFICATION...new wind tunnel swatch technique allows the systematic testing IPE components, such as fasteners, seams, and closures, for improved system...protective overgarment) achieve this isolation by sealing users in a chemically impermeable garment . Heat stress becomes a major problem with this

  12. Simulated precipitation diurnal cycles over East Asia using different CAPE-based convective closure schemes in WRF model

    NASA Astrophysics Data System (ADS)

    Yang, Ben; Zhou, Yang; Zhang, Yaocun; Huang, Anning; Qian, Yun; Zhang, Lujun

    2018-03-01

    Closure assumption in convection parameterization is critical for reasonably modeling the precipitation diurnal variation in climate models. This study evaluates the precipitation diurnal cycles over East Asia during the summer of 2008 simulated with three convective available potential energy (CAPE) based closure assumptions, i.e. CAPE-relaxing (CR), quasi-equilibrium (QE), and free-troposphere QE (FTQE) and investigates the impacts of planetary boundary layer (PBL) mixing, advection, and radiation on the simulation by using the weather research and forecasting model. The sensitivity of precipitation diurnal cycle to PBL vertical resolution is also examined. Results show that the precipitation diurnal cycles simulated with different closures all exhibit large biases over land and the simulation with FTQE closure agrees best with observation. In the simulation with QE closure, the intensified PBL mixing after sunrise is responsible for the late-morning peak of convective precipitation, while in the simulation with FTQE closure, convective precipitation is mainly controlled by advection cooling. The relative contributions of different processes to precipitation formation are functions of rainfall intensity. In the simulation with CR closure, the dynamical equilibrium in the free troposphere still can be reached, implying the complex cause-effect relationship between atmospheric motion and convection. For simulations in which total CAPE is consumed for the closures, daytime precipitation decreases with increased PBL resolution because thinner model layer produces lower convection starting layer, leading to stronger downdraft cooling and CAPE consumption. The sensitivity of the diurnal peak time of precipitation to closure assumption can also be modulated by changes in PBL vertical resolution. The results of this study help us better understand the impacts of various processes on the precipitation diurnal cycle simulation.

  13. To close or not to close: contemporary indications for patent foramen ovale closure.

    PubMed

    Zier, Lucas S; Sievert, Horst; Mahadevan, Vaikom S

    2016-11-01

    Patent foramen ovale (PFO) is a common congenital cardiac abnormality and that has been associated with several disease processes including transient ischemic attacks (TIA), stroke, migraine headaches with aura, decompression sickness, platypnea-orthodeoxia syndrome, and shunt induced cyanosis. Controversy exists regarding closure of PFO as a therapeutic treatment modality for these disease processes. This review addresses the contemporary clinical indications for PFO closure. Areas covered: We conducted a comprehensive literature search of contemporary research studies focusing on randomized trials and meta-analyses comparing medical therapy and device closure of PFOs for the treatment of PFO associated clinical syndromes. We synthesized this literature into a review addressing indications for PFO closure in stroke, TIA, migraine headaches with aura, decompression sickness, platypnea-orthodeoxia syndrome, and shunt induced cyanosis. Expert commentary: Because in many PFO associated conditions it can be difficult to determine the degree to which the PFO is a causative factor in the disease process, we recommend a comprehensive diagnostic evaluation to exclude other obvious etiologies of PFO associated conditions before implicating the PFO and proceeding with closure. However in the properly selected patient population there is growing clinical experience and experimental evidence suggesting that closure of PFO is a safe and effective treatment modality.

  14. Failure of mesenteric defect closure after Roux-en-Y gastric bypass.

    PubMed

    Hope, William W; Sing, Ronald F; Chen, Albert Y; Lincourt, Amy E; Gersin, Keith S; Kuwada, Timothy S; Heniford, B Todd

    2010-01-01

    Bowel obstructions following Roux-en-Y gastric bypass (RYGB) are a significant issue often caused by internal herniation. Controversy continues as to whether mesenteric defect closure is necessary to decrease the incidence of internal hernias after RYGB. Our purpose was to evaluate the effectiveness of closing the mesenteric defect at the jejunojejunostomy in patients who underwent RYGB by examining this potential space at reoperation for any reason. We retrospectively reviewed medical records of patients undergoing surgery after RYGB from August 1999 to October 2008 to determine the status of the mesentery at the jejunojejunostomy. Eighteen patients underwent surgery 2 to 19 months after open (n=8) or laparoscopic (n=10) RYGB. All patients had documented suture closure of their jejunojejunostomy at the time of RYGB. Permanent (n=12) or absorbable (n=6) sutures were used for closures. Patients lost 23.6 kg to 62.1 kg before a reoperation was required for a ventral hernia (n=8), cholecystectomy (n=4), abdominal pain (n=4), or small bowel obstruction (n=2). Fifteen of the 18 patients had open mesenteric defects at the jejunojejunostomy despite previous closure; none were the cause for reoperation. Routine suture closure of mesenteric defects after RYGB may not be an effective permanent closure likely due to the extensive fat loss and weight loss within the mesentery.

  15. Primary closure of lawn mower injuries to the foot: a case series.

    PubMed

    Goldsmith, Jon R; Massa, Eric G

    2007-01-01

    The standard initial treatment of lawn mower injuries to the foot consists of prompt administration of parenteral antibiotics, debridement of devitalized tissue, irrigation, repair of traumatized vascular structures, and stabilization of osseous fractures. The primary closure of these wounds at the initial operation is a controversial concept. The authors performed a retrospective study of 9 lawn mower injuries in which primary closure was performed. Medical records were evaluated, and 7 patients were reached for follow-up interviews. The hospital courses for this patient population were remarkably lower than those previously reported in the literature. No patient required further admission to the hospital or surgical intervention. The postinjury functional evaluation mean score was 97.6%. The results demonstrate that this treatment method can be an effective means for treating this mutilating injury in the foot.

  16. Loop-anchor purse-string closure of gastrotomy in NOTES(R) procedures: survival studies in a porcine model.

    PubMed

    Romanelli, John R; Desilets, David J; Chapman, Christopher N; Surti, Vihar C; Lovewell, Carolanne; Earle, David B

    2010-12-01

    Transgastric NOTES(®) procedures remain without a simple method to close the gastrotomy. In four survival swine studies, we have tested a novel gastric closure device: the loop-anchor purse-string (LAPS) closure system. In four anesthetized pigs, an endoscopic gastrotomy was performed. Four loop anchors were arrayed in a 2-cm square pattern around the gastrotomy. The endoscope was passed into the abdominal cavity, and the gastrotomy was cinched closed. Procedure times ranged from 50-180 minutes. Three pigs survived 14 days. One animal was sacrificed early due to signs of sepsis. Another animal developed fevers and was treated with antibiotics. At necropsy, there were no abscesses, including in the septic animal. Histologic examination revealed evidence of healing in all animals. The LAPS system holds promise with early success in an animal model. Future human studies are needed to determine viability as a human visceral closure device.

  17. Method and apparatus for active tamper indicating device using optical time-domain reflectometry

    DOEpatents

    Smith, D. Barton; Muhs, Jeffrey D.; Pickett, Chris A.; Earl, D. Duncan

    1999-01-01

    An optical time-domain reflectometer (OTDR) launches pulses of light into a link or a system of multiplexed links and records the waveform of pulses reflected by the seals in the link(s). If a seal is opened, the link of cables will become a discontinuous transmitter of the light pulses and the OTDR can immediately detect that a seal has been opened. By analyzing the waveform, the OTDR can also quickly determine which seal(s) were opened. In this way the invention functions as a system of active seals. The invention is intended for applications that require long-term surveillance of a large number of closures. It provides immediate tamper detection, allows for periodic access to secured closures, and can be configured for many different distributions of closures. It can monitor closures in indoor and outdoor locations and it can monitor containers or groups of containers located many kilometers apart.

  18. Uncertainty Analysis for Angle Calibrations Using Circle Closure

    PubMed Central

    Estler, W. Tyler

    1998-01-01

    We analyze two types of full-circle angle calibrations: a simple closure in which a single set of unknown angular segments is sequentially compared with an unknown reference angle, and a dual closure in which two divided circles are simultaneously calibrated by intercomparison. In each case, the constraint of circle closure provides auxiliary information that (1) enables a complete calibration process without reference to separately calibrated reference artifacts, and (2) serves to reduce measurement uncertainty. We derive closed-form expressions for the combined standard uncertainties of angle calibrations, following guidelines published by the International Organization for Standardization (ISO) and NIST. The analysis includes methods for the quantitative evaluation of the standard uncertainty of small angle measurement using electronic autocollimators, including the effects of calibration uncertainty and air turbulence. PMID:28009359

  19. Fish allergy causing angioedema and secondary angle-closure glaucoma.

    PubMed

    Calder, Donovan; Calder, Jennifer

    2013-03-06

    A 56-year-old woman with a history of primary angle-closure glaucoma presented with acute generalised swelling, and facial angioedema following a fish meal. She complained of nausea, vomiting, headache, pain in both eyes and acute loss of vision. Her visual acuity was reduced and intraocular pressures (IOP) were elevated. Gonioscopy revealed complete angle closure in the left eye and complete to partial closure in the right eye. Through existing peripheral iridotomies the anterior capsules were seen pressed up against the iris of both eyes. A diagnosis of angle-closure glaucoma was made, medications were started to reduce the elevated intraocular pressure and systemic antihistamine to counter the allergic reaction. She was hospitalised for further management. A follow-up at 2 years revealed her visual acuities and IOP had remained normal.

  20. The urethral closure function in continent and stress urinary incontinent women assessed by urethral pressure reflectometry.

    PubMed

    Saaby, Marie-Louise

    2014-02-01

    Stress urinary incontinence (SUI) occurs when the bladder pressure exceeds the urethral pressure in connection with physical effort or exertion or when sneezing or coughing and depends both on the strength of the urethral closure function and the abdominal pressure to which it is subjected. The urethral closure function in continent women and the dysfunction causing SUI are not known in details. The currently accepted view is based on the concept of a sphincteric unit and a support system. Our incomplete knowledge relates to the complexity of the closure apparatus and to inadequate assessment methods which so far have not provided robust urodynamic diagnostic tools, severity measures, or parameters to assess outcome after intervention. Urethral Pressure Reflectometry (UPR) is a novel method that measures the urethral pressure and cross-sectional area (by use of sound waves) simultaneously. The technique involves insertion of only a small, light and flexible polyurethane bag in the urethra and therefore avoids the common artifacts encountered with conventional methods. The UPR parameters can be obtained at a specific site of the urethra, e.g. the high pressure zone, and during various circumstances, i.e. resting and squeezing. During the study period, we advanced the UPR technique to enable faster measurement (within 7 seconds by the continuous technique) which allowed assessment during increased intra-abdominal pressure induced by physical straining. We investigated the urethral closure function in continent and SUI women during resting and straining by the "fast" UPR technique. Thereby new promising urethral parameters were provided that allowed characterization of the closure function based on the permanent closure forces (primarily generated by the sphincteric unit, measured by the Po-rest) and the adjunctive closure forces (primarily generated by the support system, measured by the abdominal to urethral pressure impact ratio (APIR)). The new parameters enabled a more detailed description of the efficiency of the closure function and the extent and nature of a possible dysfunction in the individual woman. The urethral closure equation (UCE) and urethral opening pressure at an abdominal pressure of 50 cm H2O (Po-Abd 50), respectively, which combine the permanent and the adjunctive closure forces, could separate continent and SUI women and thus appear to be excellent diagnostic tests. Moreover, the parameters showed highly significant negative correlation with ICIQ-SF, pad test and the number of incontinence episodes per week and are therefore valid as urodynamic severity measures. UPR in SUI women before and after TVT demonstrated a more efficient urethral closure function after the operation. The Po-rest was unchanged suggesting that the sphincteric unit was virtually unaltered and hence the permanent closure forces unchanged. However, the resting opening elastance increased by 18% indicating that at the resting state the TVT somewhat improves the closure function by providing increased resistance against the dilation of the urethra, which probably explains the decreased maximum urine flow rate found after TVT in this and previous studies. The APIR increased in all patients after TVT suggesting that the support system was re-established and thus the adjunctive closure forces improved, regardless of the type of pre-operative dysfunction. The new UPR parameters may be used as outcome measures after treatment.

  1. The TopClosure® 3S System, for skin stretching and a secure wound closure.

    PubMed

    Topaz, Moris; Carmel, Narin-Nard; Silberman, Adi; Li, Ming Sen; Li, Yong Zhong

    2012-07-01

    The principle of stretching wound margins for primary wound closure is commonly practiced and used for various skin defects, leading at times to excessive tension and complications during wound closure. Different surgical techniques, skin stretching devices and tissue expanders have been utilized to address this issue. Previously designed skin stretching devices resulted in considerable morbidity. They were invasive by nature and associated with relatively high localized tissue pressure, frequently leading to necrosis, damage and tearing of skin at the wound margins. To assess the clinical effectiveness and performance and, to determine the safety of TopClosure® for gradual, controlled, temporary, noninvasive and invasive applications for skin stretching and secure wound closing, the TopClosure® device was applied to 20 patients for preoperative skin lesion removal and to secure closure of a variety of wound sizes. TopClosure® was reinforced with adhesives, staples and/or surgical sutures, depending on the circumstances of the wound and the surgeon's judgment. TopClosure® was used prior to, during and/or after surgery to reduce tension across wound edges. No significant complications or adverse events were associated with its use. TopClosure® was effectively used for preoperative skin expansion in preparation for dermal resection (e.g., congenital nevi). It aided closure of large wounds involving significant loss of skin and soft tissue by mobilizing skin and subcutaneous tissue, thus avoiding the need for skin grafts or flaps. Following surgery, it was used to secure closure of wounds under tension, thus improving wound aesthetics. A sample case study will be presented. We designed TopClosure®, an innovative device, to modify the currently practiced concept of wound closure by applying minimal stress to the skin, away from damaged wound edges, with flexible force vectors and versatile methods of attachment to the skin, in a noninvasive or invasive manner.

  2. WHAT ARE THE BEST MEANS TO ASSESS CONTAMINANT TRANSPORT AND BIODEGRADATION AND MOVE TOWARD CLOSURE, USING APPROPRIATE SITE-SPECIFIC RISK EVALUATIONS?

    EPA Science Inventory

    Site remedy and closure decisions are made from a mixture of site data, literature values, and model results. Often assessment of this information is difficult for State Agency case managers because conventional approaches to site characterization do not yield a clear and strai...

  3. Best management practices for erosion control from bladed skid trails

    Treesearch

    Charles R. Wade; W. Michael Aust; M. Chad Bolding; William A. Lakel III

    2012-01-01

    Sediment from forest operations is primarily associated with roads and skid trails. We evaluated five skid trail closure treatments applied to bladed skid trails in the Virginia Piedmont. Closure treatments were Waterbars, Seed, Mulch, Pine slash, and Hardwood slash. Sediment traps were used to collect monthly sediment samples for one year. The Mulch, Pine slash, and...

  4. Impacts of tree height on leaf hydraulic architecture and stomatal control in Douglas-fir.

    Treesearch

    D.R. Woodruff; K.A. McCulloh; J.M. Warren; F.C. Meinzer; B.L. Gartner

    2007-01-01

    We investigated the mechanisms involved in the regulation of stomatal closure in Douglas-fir and evaluated the potential compensatory adjustments in response to increasing tree height. Stomatal closure was initiated at values of leaf water potential corresponding to nearly complete loss of leaf hydraulic conductance. Cryogenic scanning electron microscopic images...

  5. Semantic Evaluation of Syntactic Structure: Evidence from Eye Movements

    ERIC Educational Resources Information Center

    Frazier, Lyn; Carminati, Maria Nella; Cook, Anne E.; Majewski, Helen; Rayner, Keith

    2006-01-01

    An eye movement study of temporarily ambiguous closure sentences confirmed that the early closure penalty in a sentence like "While John hunted the frightened deer escaped" is larger for a simple past verb ("hunted") than for a past progressive verb ("was hunting"). The results can be explained by the observation that simple past tense verbs…

  6. Unilateral Angle-Closure Glaucoma with Ciliochoroidal Effusion after the Consumption of Cannabis: A Case Report

    PubMed Central

    Hanna, Rana; Tiosano, Beatrice; Dbayat, Noora; Gaton, Dan

    2014-01-01

    A 35-year-old male patient, diagnosed with acute angle-closure glaucoma, did not improve despite intensive treatment with antiglaucoma medications. Ultrasound biomicroscopy revealed a ciliochoroidal effusion. Due to his past history of drug abuse, a urine test was analyzed and found to be positive for cannabis. After topical cycloplegia and oral steroid therapy, his symptoms improved substantially. The present case highlights the role of ultrasound biomicroscopy in evaluating patients with acute angle-closure glaucoma and the role of cannabis abuse in the development of ciliochoroidal effusion. PMID:25606036

  7. Development and Testing of a Mobile Platform for Tank Remediation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nance, T.A.

    2001-01-16

    The Department of Energy (DOE) is committed to removing millions of gallons of high level radioactive waste from waste storage tanks at the Savannah River Site (SRS). SRS was the first site in the DOE complex to have emptied and closed high level waste tanks. Tank closure at the Site is now progressing to tanks containing waste composed of liquid and large deposits of solids, including a tank that has a potential ''heel''. A heel is a hardened mass of solid waste material spread across the tank bottom. Tank closure requires breaking up this heel and moving the material tomore » the intake of a pumping system for transfer from the tank. In the past, overhead spray systems have been used with some success at moving waste. But the limited number of risers restricts the coverage area of the overhead spray system. Therefore, a floor- level spray system will be used to separate manageable size chunks of the material from the heel. The chunks will be guided into the pump's intake to be remove from the tank. The floor-level spray system movement will be accomplished by using a mobile platform, a crawler, which provides transport to nearly every point on the tank floor. Transport of the spray system will allow the system to ''corral'' the waste away from the tank walls and control the movement of the material across the tank floor. Because the available access riser is small, and a wide crawler platform is required to support the spray system, the crawler's frame must fold to enter the tank. After entry into the tank, the crawler unfolds on the tank floor using the crawler drive tracks to expand the frame and position the mobile platform under the entry riser. The spray system will then be lowered separately through the entry riser and mated onto the crawler on the tank floor. The crawler and spray system are tethered and controlled remotely by personnel at the control station. Motorized cable reels will also be remotely controlled to pay out, retrieve, and manage the tethers as the mobile platform moves the spray system across the tank floor. Both the crawler and spray systems are designed to be retrievable. Development of the tank cleaning system was evaluated using a performance test program. The tests evaluated the spray system dynamics, the crawler's fit through the riser, the crawler landing in mocked up tank with simulant, the crawler's traction, and the crawler and spray system mating. Initial testing verified the crawler platform was compatible with the dynamics produced by the spray system. The riser fit test confirmed that a dedicated riser is required for deployment of the crawler and the spray system. The crawler traction test defined the capabilities of the crawler at different levels of simulant. Deployment testing through a mockup riser verified the basic system processes. Finally, testing of the complete system in a full-scale mockup with sludge simulant was performed to evaluate the tank cleaning ability of the crawler. This paper describes th e tank conditions, the tank closure process, the development of the crawler and spray system, and the testing program and results used to evaluate the mobile platform and spray system.« less

  8. Ethnic differences in primary angle-closure glaucoma.

    PubMed

    Yip, Jennifer L Y; Foster, Paul J

    2006-04-01

    Observational studies from different countries have shown that populations of East Asian origin have a higher frequency of primary angle-closure glaucoma compared with those of European or African descent. As half of all cases of glaucoma reside in Asia, and with primary angle-closure glaucoma carrying a higher rate of visual morbidity, primary angle-closure glaucoma poses an important public health problem; however, the inconsistent use of techniques and definitions to detect and diagnose primary angle-closure glaucoma has resulted in difficulties in interpreting the accuracy and comparability of such data. Therefore it is important to review these studies in the light of a consistent classification system. There are increasing reports that support previous findings on the incidence and prevalence of primary angle-closure glaucoma in different ethnic groups. There have also been further investigations into the mechanism and natural history of primary angle-closure glaucoma in Asian populations. International investigations into primary angle-closure glaucoma have demonstrated reproducible evidence that ethnic variations do exist. Cross-sectional studies in this area have also suggested that differences in anterior chamber depth, together with its association with peripheral anterior synechiae, may be part of the underlying mechanism behind these differences. The ideas generated need to be further explored with longitudinal data of changes in anterior chamber depth and peripheral anterior synechiae in different populations. The detailed mechanisms behind the development of angle-closure and primary angle-closure glaucoma should also be investigated.

  9. 75 FR 34172 - Rexam Closure Systems, Inc., a Subsidiary of Rexam PLC, Including On-Site Leased Workers From...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-16

    ..., Inc., a Subsidiary of Rexam PLC, Including On-Site Leased Workers From Addeco Employment Services and... PLC, Hamlet, North Carolina. The notice was published in the Federal Register on April 23, 2010 (75 FR... at the Hamlet, North Carolina location of Rexam Closure Systems, Inc., a subsidiary of Rexam PLC. The...

  10. A comparative anchorage control study between conventional and self-ligating bracket systems using differential moments.

    PubMed

    de Almeida, Marcio Rodrigues; Herrero, Francisco; Fattal, Amine; Davoody, Amirparviz R; Nanda, Ravindra; Uribe, Flavio

    2013-11-01

    To compare the efficiency in anchorage preservation of conventional and self-ligating brackets after the extraction of first maxillary premolars using differential moment mechanics. Thirty-eight patients requiring extraction of maxillary first premolars and maximum anchorage during space closure were evaluated based on bracket type. Group 1, comprising 23 patients, was bonded with preadjusted conventional brackets (CBs) with a slot of 0.022-inch × 0.030-inch. Group 2 comprised 15 patients who were bonded with 0.022 inch preadjusted self-ligating brackets (SLBs). Patients in both groups received a nickel titanium (NiTi) intrusion arch and a 150 g NiTi closing coil spring for separate canine retraction, followed by a continuous mushroom loop archwire to retract the incisors. Lateral cephalograms were available at the start of treatment (T1) and at the completion of space closure (T2). Statistical comparisons were performed with paired and unpaired Student's t-tests. No significant differences were found between the groups in maxillary molars anchorage loss (3.87 ± 1.35 mm and 3.65 ± 1.73 mm for the CB and SLB groups, respectively). Only the mean vertical movement of the tip of the incisor was significantly different between the groups (CB  =  -0.92 ± 1.46 mm; SLB  =  0.56 ± 1.65 mm). There were no significant differences in the amount of anchorage loss of the maxillary first molars between SLB and CB systems during space closure using differential moments.

  11. Left atrial appendage closure with the Watchman device in patients with a contraindication for oral anticoagulation: the ASAP study (ASA Plavix Feasibility Study With Watchman Left Atrial Appendage Closure Technology).

    PubMed

    Reddy, Vivek Y; Möbius-Winkler, Sven; Miller, Marc A; Neuzil, Petr; Schuler, Gerhard; Wiebe, Jens; Sick, Peter; Sievert, Horst

    2013-06-25

    The purpose of this study was to assess the safety and efficacy of left atrial appendage (LAA) closure in nonvalvular atrial fibrillation (AF) patients ineligible for warfarin therapy. The PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) trial demonstrated that LAA closure with the Watchman device (Boston Scientific, Natick, Massachusetts) was noninferior to warfarin therapy. However, the PROTECT AF trial only included patients who were candidates for warfarin, and even patients randomly assigned to the LAA closure arm received concomitant warfarin for 6 weeks after Watchman implantation. A multicenter, prospective, nonrandomized study was conducted of LAA closure with the Watchman device in 150 patients with nonvalvular AF and CHADS₂ (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, and prior stroke or transient ischemic attack) score ≥1, who were considered ineligible for warfarin. The primary efficacy endpoint was the combined events of ischemic stroke, hemorrhagic stroke, systemic embolism, and cardiovascular/unexplained death. The mean CHADS₂ score and CHA₂DS₂-VASc (CHADS₂ score plus 2 points for age ≥75 years and 1 point for vascular disease, age 65 to 74 years, or female sex) score were 2.8 ± 1.2 and 4.4 ± 1.7, respectively. History of hemorrhagic/bleeding tendencies (93%) was the most common reason for warfarin ineligibility. Mean duration of follow-up was 14.4 ± 8.6 months. Serious procedure- or device-related safety events occurred in 8.7% of patients (13 of 150 patients). All-cause stroke or systemic embolism occurred in 4 patients (2.3% per year): ischemic stroke in 3 patients (1.7% per year) and hemorrhagic stroke in 1 patient (0.6% per year). This ischemic stroke rate was less than that expected (7.3% per year) based on the CHADS₂ scores of the patient cohort. LAA closure with the Watchman device can be safely performed without a warfarin transition, and is a reasonable alternative to consider for patients at high risk for stroke but with contraindications to systemic oral anticoagulation. (ASA Plavix Feasibility Study With Watchman Left Atrial Appendage Closure Technology [ASAP]; NCT00851578). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Closure measures for coarse-graining of the tent map.

    PubMed

    Pfante, Oliver; Olbrich, Eckehard; Bertschinger, Nils; Ay, Nihat; Jost, Jürgen

    2014-03-01

    We quantify the relationship between the dynamics of a time-discrete dynamical system, the tent map T and its iterations T(m), and the induced dynamics at a symbolical level in information theoretical terms. The symbol dynamics, given by a binary string s of length m, is obtained by choosing a partition point [Formula: see text] and lumping together the points [Formula: see text] s.t. T(i)(x) concurs with the i - 1th digit of s-i.e., we apply a so called threshold crossing technique. Interpreting the original dynamics and the symbolic one as different levels, this allows us to quantitatively evaluate and compare various closure measures that have been proposed for identifying emergent macro-levels of a dynamical system. In particular, we can see how these measures depend on the choice of the partition point α. As main benefit of this new information theoretical approach, we get all Markov partitions with full support of the time-discrete dynamical system induced by the tent map. Furthermore, we could derive an example of a Markovian symbol dynamics whose underlying partition is not Markovian at all, and even a whole hierarchy of Markovian symbol dynamics.

  13. Method Development for Container Closure Integrity Evaluation via Headspace Gas Ingress by Using Frequency Modulation Spectroscopy.

    PubMed

    Victor, Ken G; Levac, Lauren; Timmins, Michael; Veale, James

    2017-01-01

    USP <1207.1> Section 3.5 states that "A deterministic leak test method having the ability to detect leaks at the product's maximum allowable leakage limit is preferred when establishing the inherent integrity of a container-closure system." Ideally, container closure integrity of parenteral packaging would be evaluated by measuring a physical property that is sensitive to the presence of any package defect that breaches package integrity by increasing its leakage above its maximum allowable leakage limit. The primary goals of the work presented herein were to demonstrate the viability of the nondestructive, deterministic method known as laser-based gas headspace analysis for evaluating container closure integrity and to provide a physical model for predicting leak rates for a variety of container volumes, headspace conditions, and defect sizes. The results demonstrate that laser-based headspace analysis provides sensitive, accurate, and reproducible measurements of the gas ingress into glass vial-stopper package assemblies that are under either diffusive or effusive leak conditions. Two different types of positive controls were examined. First, laser-drilled micro-holes in thin metal disks that were crimped on top of 15R glass vials served as positive controls with a well-characterized defect geometry. For these, a strong correlation was observed between the measured ingress parameter and the size of the defect for both diffusive and effusive conditions. Second, laser-drilled holes in the wall of glass vials served as controls that more closely simulate real-world defects. Due to their complex defect geometries, their diffusive and effusive ingress parameters did not necessarily correlate; this is an important observation that has significant implications for standardizing the characterization of container defects. Regardless, laser-based headspace analysis could readily differentiate positive and negative controls for all leak conditions, and the results provide a guide for method development of container closure integrity tests. LAY ABSTRACT: The new USP 39 <1207>, "Package Integrity Evaluation-Sterile Products", states in section 3.4.1: "tracer gas tests performed using … laser-based gas headspace analysis [have] been shown to be sensitive enough to quantitatively analyze leakage through the smallest leak paths found to pose the smallest chance of liquid leakage or microbial ingress in rigid packaging." In addition, USP <1207> also states that "for such methods, the limit of detection can be mathematically predicted on the basis of gas flow kinetics." Using the above statements as a foundation, this paper presents a theoretical basis for predicting the gas ingress through well-defined defects in product vials sealed under a variety of headspace conditions. These calculated predictions were experimentally validated by comparing them to measurements of changes in the headspace oxygen content or total pressure for several different positive controls using laser-based headspace analysis. The results demonstrated that laser-based headspace analysis can, by readily differentiating between negative controls and positive controls with a range of defect sizes on the micron scale, be used to assess container closure integrity. The work also demontrated that caution must be used when attempting to correlate a leak rate to an idealized defect-size parameter. © PDA, Inc. 2017.

  14. Does velopharyngeal closure pattern affect the success of pharyngeal flap pharyngoplasty?

    PubMed

    Armour, Alexis; Fischbach, Simone; Klaiman, Paula; Fisher, David M

    2005-01-01

    Historically at The Hospital for Sick Children in Toronto, pharyngeal flap pharyngoplasty has been the treatment of choice for treatment of velopharyngeal insufficiency, regardless of velopharyngeal closure pattern. The authors hypothesize that pharyngeal flap pharyngoplasty is more effective in treating velopharyngeal insufficiency in patients with circular or sagittal velopharyngeal closure and less effective in treating the coronal closure pattern. Ninety-three patients who underwent superiorly based pharyngeal flap surgery for velopharyngeal insufficiency were evaluated in a retrospective chart review. Closure pattern was determined preoperatively by nasopharyngoscopy or multiview videofluoroscopy. Nasalance was assessed preoperatively and at 6 weeks and 1 year postoperatively. Nasalance during nonnasal speech was decreased on average, for all closure patterns, postoperatively. However, a significantly higher percentage of patients were corrected to normal nasalance scores in thenoncoronal group than in the coronal group (57 percent versus 35 percent, respectively) at 1 year postoperatively (p < 0.05). Surgical overcorrection, as determined by postoperative hyponasality, occurred at a rate of 13 percent in the coronal group versus 7 percent in the noncoronal group (not statistically significant). The results demonstrate that hypernasality in patients with a coronal velopharyngeal closure pattern can be improved by pharyngeal flap pharyngoplasty. This procedure, however, is more frequently effective in correcting noncoronal closure pattern velopharyngeal insufficiency than coronal pattern velopharyngeal insufficiency. The authors are now more selective in their approach to the management of velopharyngeal insufficiency and are more inclined to treat coronal pattern velopharyngeal insufficiency with sphincter pharyngoplasty.

  15. Intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency: a safe alternative to surgical repair.

    PubMed

    Chen, Qiang; Chen, Liang-Wan; Cao, Hua; Zhang, Gui-Can; Chen, Dao-Zhong; Zhang, Hui

    2011-03-01

    Our objective was to evaluate the safety and feasibility of intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency. From January 2005 to December 2008, we enrolled 65 patients who had a secundum atrial septal defect with inferior vena cava rim deficiency closure in our institution. Patients were divided into 2 groups: 35 patients in group I underwent intraoperative device closure with a right lateral minithoracotomy and 30 in group II underwent open cardiac repair with a right lateral thoracotomy and cardiopulmonary bypass. Intraoperative device closure involved a minimal intercostal incision that was performed after full evaluation of the atrial septal defect by transthoracic echocardiography and the insertion of the device through the delivery sheath to occlude the atrial septal defect. The procedure was successful in all patients. In group I, the diameter of the atrial septal defect ranged from 30 to 44 mm (mean, 35.3 ± 3.9 mm), and the size of the implanted occluder ranged from 34 to 48 mm (mean, 40 ± 2.1 mm). The total occlusion rate was 82.9% immediately after the operation, 97.1% at 3 months, and 100% at 12 and 24 months of follow-up. In group II, all patients had successful closure. A follow-up period of 12 to 24 months was obtained in both groups. During the follow-up, there was no recurrence, thrombosis, or device failure. In our comparative studies, group II had significantly longer operative time, intensive care unit stay, and hospital stay than group I (P < .001). The cost of group I was less than that of group II (20,450.9 ± 840.8 RMB vs 25,884.9 ± 701.8; P < .001). Intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency is a safe and feasible technique. It has the advantages of cost savings, cosmetic results, and less trauma than surgical closure. Early and midterm results are encouraging. Crown Copyright © 2011. Published by Mosby, Inc. All rights reserved.

  16. Prospective Randomized Study of the Effect of Music on the Efficiency of Surgical Closures.

    PubMed

    Lies, Shelby R; Zhang, Andrew Y

    2015-09-01

    Music is commonly played in operating theaters. Some surgeons believe music reduces stress and operative time, while others think music is a distraction and should be avoided. There is limited published evidence evaluating the effects of music on surgical performance. The goal of this study is to evaluate the effect of music on simple wound closure. Plastic surgery residents were asked to perform layered closures on pigs' feet with and without their preferred music playing. Simple randomization was used to assign residents to the music playing first or music playing second group. The time to complete the repair was measured and repairs were graded by blinded faculty. Results were analyzed to determine significant differences in time to complete the task and quality of repair. Participants were retested in a second session with music played in the opposite order to evaluate consistency. Listening to preferred music decreased repair time by 8% for all plastic surgery residents (p = 0.009). Subgroup analysis demonstrated even more significant improvement in speed for senior residents (PGY 4-6), resulting in a 10% decrease in repair time (p = 0.006). The quality of repair was also better in the music group, at 3.3 versus 3.1 (p = 0.047). Retesting revealed results remained significant whether music was played first or second. Playing preferred music made plastic surgery residents faster in completing wound closure with a 10% improvement in senior residents. Music also improved quality of repair as judged by blinded faculty. Our study showed that music improves efficiency of wound closure, which may translate to healthcare cost savings. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  17. System-Scale Model of Aquifer, Vadose Zone, and River Interactions for the Hanford 300 Area - Application to Uranium Reactive Transport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rockhold, Mark L.; Bacon, Diana H.; Freedman, Vicky L.

    2013-10-01

    This report represents a synthesis and integration of basic and applied research into a system-scale model of the Hanford 300 Area groundwater uranium plume, supported by the U.S. Department of Energy’s Richland Operations (DOE-RL) office. The report integrates research findings and data from DOE Office of Science (DOE-SC), Office of Environmental Management (DOE-EM), and DOE-RL projects, and from the site remediation and closure contractor, Washington Closure Hanford, LLC (WCH). The three-dimensional, system-scale model addresses water flow and reactive transport of uranium for the coupled vadose zone, unconfined aquifer, and Columbia River shoreline of the Hanford 300 Area. The system-scale modelmore » of the 300 Area was developed to be a decision-support tool to evaluate processes of the total system affecting the groundwater uranium plume. The model can also be used to address “what if” questions regarding different remediation endpoints, and to assist in design and evaluation of field remediation efforts. For example, the proposed cleanup plan for the Hanford 300 Area includes removal, treatment, and disposal of contaminated sediments from known waste sites, enhanced attenuation of uranium hot spots in the vadose and periodically rewetted zone, and continued monitoring of groundwater with institutional controls. Illustrative simulations of polyphosphate infiltration were performed to demonstrate the ability of the system-scale model to address these types of questions. The use of this model in conjunction with continued field monitoring is expected to provide a rigorous basis for developing operational strategies for field remediation and for defining defensible remediation endpoints.« less

  18. Percutaneous Closure of Patent Foramen Ovale in Patients With Migraine: The PREMIUM Trial.

    PubMed

    Tobis, Jonathan M; Charles, Andrew; Silberstein, Stephen D; Sorensen, Sherman; Maini, Brijeshwar; Horwitz, Phillip A; Gurley, John C

    2017-12-05

    Migraine is a prevalent and disabling disorder. Patent foramen ovale (PFO) has been associated with migraine, but its role in the disorder remains poorly understood. This study examined the efficacy of percutaneous PFO closure as a therapy for migraine with or without aura. The PREMIUM (Prospective, Randomized Investigation to Evaluate Incidence of Headache Reduction in Subjects With Migraine and PFO Using the AMPLATZER PFO Occluder to Medical Management) was a double-blind study investigating migraine characteristics over 1 year in subjects randomized to medical therapy with a sham procedure (right heart catheterization) versus medical therapy and PFO closure with the Amplatzer PFO Occluder device (St. Jude Medical, St. Paul, Minnesota). Subjects had 6 to 14 days of migraine per month, had failed at least 3 migraine preventive medications, and had significant right-to-left shunt defined by transcranial Doppler. Primary endpoints were responder rate defined as 50% reduction in migraine attacks and adverse events. Secondary endpoints included reduction in migraine days and efficacy in patients with versus without aura. Of 1,653 subjects consented, 230 were enrolled. There was no difference in responder rate in the PFO closure (45 of 117) versus control (33 of 103) groups. One serious adverse event (transient atrial fibrillation) occurred in 205 subjects who underwent PFO closure. Subjects in the PFO closure group had a significantly greater reduction in headache days (-3.4 vs. -2.0 days/month, p = 0.025). Complete migraine remission for 1 year occurred in 10 patients (8.5%) in the treatment group versus 1 (1%) in the control group (p = 0.01). PFO closure did not meet the primary endpoint of reduction in responder rate in patients with frequent migraine. (Prospective, Randomized Investigation to Evaluate Incidence of Headache Reduction in Subjects With Migraine and PFO Using the AMPLATZER PFO Occluder to Medical Management [PREMIUM]; NCT00355056). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Safety and feasibility of intra-operative device closure of atrial septal defect with transthoracic minimal invasion.

    PubMed

    Chen, Qiang; Cao, Hua; Zhang, Gui-Can; Chen, Liang-Wan; Chen, Dao-Zhong

    2012-01-01

    The study aims to evaluate the safety and feasibility of intra-operative device closure of atrial septal defect with transthoracic minimal invasion. From May 2006 to June 2009, 252 patients with secundum-type atrial septal defect closure were enrolled in our institution. The patients were divided into two groups, with 182 patients in group I with intra-operative device closure and 72 in group II with surgical closure. In group I, the patients' age ranged from 3 months to 62 years (mean±standard deviation, 19.0±16.7 years). This approach involved a transthoracic minimal invasion that was performed after full evaluation of the atrial septal defect by transthoracic echocardiography, deploying the device through the delivery sheath to occlude the atrial septal defect. In group I, 180 patients were occluded successfully under this approach. The size of the occluder device implanted ranged from 6 to 48 mm. Minor complications occurred, which included transient arrhythmias (n=23) and pleural effusion (n=15). Two patients with postoperative cardiac arrest were successfully cardiopulmonary resuscitated. Another two patients with occluder dislodged back into the right atrium were turned to surgical repair with cardiopulmonary bypass on the postoperative day. In group II, all patients were occluded successfully, and almost all patients needed blood transfusion and suffered from various minor complications. All discharged patients were followed up for 1-5 years. During this period, we found no recurrence, no thrombosis, even no device failure. In our comparative studies, group II had significantly longer intensive care unit (ICU) stay and hospital stay than group I (p<0.05). The cost for group I was less than group II (p<0.05). Intra-operative device closure of atrial septal defect with transthoracic minimal invasion is a safe and feasible technique. It had the advantages of cost savings, yielding better cosmetic results, and leaving less trauma than surgical closure.

  20. Potential supplementary utility of combined PFA-100 and functional von Willebrand factor testing for the laboratory assessment of desmopressin and factor concentrate therapy in von Willebrand disease.

    PubMed

    Favaloro, Emmanuel J; Thom, Jim; Patterson, David; Just, Sarah; Baccala, Maria; Dixon, Tracy; Meiring, Muriel; Koutts, Jerry; Rowell, John; Baker, Ross

    2009-09-01

    We performed a retrospective audit of cross-laboratory testing of desmopressin and factor concentrate therapy to assess the potential utility of supplementary testing using the PFA-100 with functional von Willebrand factor (VWF) activity testing. Data were evaluated for a large number of patients with von Willebrand disease of type 1, type 2A or type 2M, as well as a comparative subset of individuals with haemophilia or carriers of haemophilia. Laboratory testing comprised pre and postdesmopressin, or pre and postconcentrate, evaluation of factor VIII, VWF antigen (VWF:Ag) and VWF ristocetin cofactor activity as traditionally performed, supplemented with collagen-binding (VWF:CB) testing and PFA-100 closure times. In brief, both therapies tended to normalize VWF test parameters and closure times in individuals with type 1 von Willebrand disease, with the level of correction in closure times related to the level of normalization of VWF, particularly the VWF:CB. However, although occasional correction of closure times was observed in patients with type 2A or type 2M von Willebrand disease, these did not in general normalize PFA-100 closure times either with desmopressin or factor concentrate therapy. In these patients, improvement in closure times was more likely in those in whom VWF:CB values normalized or when VWF:CB/VWF:Ag ratios normalized. This study confirms that there is a strong relationship between the presenting levels of plasma VWF and PFA-100 closure times, and that the supplementary combination of PFA-100 and VWF:CB testing might provide added clinical utility to current broadly applied testing strategies limited primarily to VWF:Ag, VWF ristocetin cofactor and factor VIII:coagulant. Future prospective investigations are warranted to validate these relationships and to investigate their therapeutic implications.

  1. Development of a Novel System to Measure a Clearance of a Passenger Platform

    NASA Astrophysics Data System (ADS)

    Shimizu, M.; Oizumi, J.; Matsuoka, R.; Takeda, H.; Okukura, H.; Ooya, A.; Koike, A.

    2016-06-01

    Clearances of a passenger platform at a railway station should be appropriately maintained for safety of both trains and passengers. In most Japanese railways clearances between a platform and a train car is measured precisely once or twice a year. Because current measurement systems operate on a track, the closure of the track is unavoidable. Since the procedure of the closure of a track is time-consuming and bothersome, we decided to develop a new system to measure clearances without the closure of a track. A new system is required to work on a platform and the required measurement accuracy is less than several millimetres. We have adopted a 3D laser scanner and stop-and-go operation for a new system. The current systems on a track measure clearances continuously at walking speed, while our system on a platform measures clearances at approximately ten metres intervals. The scanner controlled by a PC acquires a set of point data at each measuring station. Edge points of the platform, top and side points of two rails are detected from the acquired point data. Finally clearances of the platform are calculated by using the detected feature points of the platform and the rails. The results of an experiment using a prototype of our system show that the measurement accuracy by our system would be satisfactory, but our system would take more time than the current systems. Since our system requires no closure of a track, we conclude that our system would be convenient and effective.

  2. Probabilistic density function method for nonlinear dynamical systems driven by colored noise.

    PubMed

    Barajas-Solano, David A; Tartakovsky, Alexandre M

    2016-05-01

    We present a probability density function (PDF) method for a system of nonlinear stochastic ordinary differential equations driven by colored noise. The method provides an integrodifferential equation for the temporal evolution of the joint PDF of the system's state, which we close by means of a modified large-eddy-diffusivity (LED) closure. In contrast to the classical LED closure, the proposed closure accounts for advective transport of the PDF in the approximate temporal deconvolution of the integrodifferential equation. In addition, we introduce the generalized local linearization approximation for deriving a computable PDF equation in the form of a second-order partial differential equation. We demonstrate that the proposed closure and localization accurately describe the dynamics of the PDF in phase space for systems driven by noise with arbitrary autocorrelation time. We apply the proposed PDF method to analyze a set of Kramers equations driven by exponentially autocorrelated Gaussian colored noise to study nonlinear oscillators and the dynamics and stability of a power grid. Numerical experiments show the PDF method is accurate when the noise autocorrelation time is either much shorter or longer than the system's relaxation time, while the accuracy decreases as the ratio of the two timescales approaches unity. Similarly, the PDF method accuracy decreases with increasing standard deviation of the noise.

  3. Complete closure of artificial gastric ulcer after endoscopic submucosal dissection by combined use of a single over-the-scope clip and through-the-scope clips (with videos).

    PubMed

    Maekawa, Satoshi; Nomura, Ryosuke; Murase, Takayuki; Ann, Yasuyoshi; Harada, Masaru

    2015-02-01

    A 5-7 day hospital stay is usually needed after endoscopic submucosal dissection (ESD) of gastric tumor because of the possibility of delayed perforation or bleeding. The aim of this study was to evaluate the efficacy of combined use of a single over-the-scope clip (OTSC) and through-the-scope clips (TTSCs) to achieve complete closure of artificial gastric ulcer after ESD. We prospectively studied 12 patients with early gastric cancer or gastric adenoma. We performed complete closure of post-ESD artificial gastric ulcer using a combination of a single OTSC and TTSCs. Mean size of post-ESD artificial ulcer was 54.6 mm. The mean operating time for the closure procedure was 15.2 min., and the success rate was 91.7 % (11/12). Patients who underwent complete closure of post-ESD artificial gastric ulcer could be discharged the day after ESD and the closing procedure. Complete closure of post-ESD artificial gastric ulcer using a combination of a single OTSC and TTSCs is useful for shortening the period of hospitalization and reducing treatment cost.

  4. Corrective Action Decision Document/Closure Report for Corrective Action 405: Area 3 Septic Systems, Tonopah Test Range, Nevada Rev. No.: 0, April 2002

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    IT Coroporation, Las Vegas, NV

    2002-04-17

    This Corrective Action Decision Document/Closure Report (CADD/CR) has been prepared for Corrective Action Unit (CAU) 405, Area 3 Septic Systems, in accordance with the Federal Facility Agreement and Consent Order. Located on the Tonopah Test Range (TTR) approximately 235 miles north of Las Vegas, Nevada, CAU 405 consists of three Corrective Action Sites (CASs): 03-05-002-SW03, Septic Waste System (aka: Septic Waste System [SWS] 3); 03-05-002-SW04, Septic Waste System (aka: SWS 4); 03-05-002-SW07, Septic Waste System (aka: SWS 7). The CADD and CR have been combined into one report because no further action is recommended for this CAU, and this reportmore » provides specific information necessary to support this recommendation. The CAU consists of three leachfields and associated collection systems that were installed in or near Area 3 for wastewater disposal. These systems were used until a consolidated sewer system was installed in 1990. Historically, operations within various buildin gs in and near Area 3 of the TTR generated sanitary and industrial wastewaters. There is a potential that contaminants of concern (COCs) were present in the wastewaters and were disposed of in septic tanks and leachfields. The justification for closure of this CAU without further action is based on process knowledge and the results of the investigative activities. Closure activities were performed at these CASs between January 14 and February 2, 2002, and included the removal and proper disposal of media containing regulated constituents and proper closure of septic tanks. No further action is appropriate because all necessary activities have been completed. No use restrictions are required to be imposed for these sites since the investigation showed no evidence of COCs identified in the soil for CAU 405.« less

  5. Closure Report for Corrective Action Unit 562: Waste Systems, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2012-08-15

    This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 562, Waste Systems, and provides documentation supporting the completed corrective actions and confirmation that closure objectives for CAU 562 were met. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 as amended). CAU 562 consists of the following 13 Corrective Action Sites (CASs), located in Areas 2, 23, and 25 of the Nevadamore » National Security Site: · CAS 02-26-11, Lead Shot · CAS 02-44-02, Paint Spills and French Drain · CAS 02-59-01, Septic System · CAS 02-60-01, Concrete Drain · CAS 02-60-02, French Drain · CAS 02-60-03, Steam Cleaning Drain · CAS 02-60-04, French Drain · CAS 02-60-05, French Drain · CAS 02-60-06, French Drain · CAS 02-60-07, French Drain · CAS 23-60-01, Mud Trap Drain and Outfall · CAS 23-99-06, Grease Trap · CAS 25-60-04, Building 3123 Outfalls Closure activities began in October 2011 and were completed in April 2012. Activities were conducted according to the Corrective Action Plan for CAU 562 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2011). The corrective actions included No Further Action and Clean Closure. Closure activities generated sanitary waste and hazardous waste. Some wastes exceeded land disposal limits and required offsite treatment prior to disposal. Other wastes met land disposal restrictions and were disposed in appropriate onsite or offsite landfills. NNSA/NSO requests the following: · A Notice of Completion from the Nevada Division of Environmental Protection to NNSA/NSO for closure of CAU 562 · The transfer of CAU 562 from Appendix III to Appendix IV, Closed Corrective Action Units, of the FFACO« less

  6. Experience With Wound VAC and Delayed Primary Closure of Contaminated Soft Tissue Injuries in Iraq

    DTIC Science & Technology

    2006-11-01

    wound was definitively closed by delayed primary closure, flap mobilization, or split-thickness skin grafting . The VAC system was also used...postoperatively for 3 to 5 days over skin grafts , then removed at the bedside to assess graft take. Granulation tissue was not a prerequisite for wound closure...hospital until the closed wounds were clean and dry with good skin graft incorporation. All patients were scheduled for follow-up in our outpatient

  7. Deformable Bullnose Energy Absorbing System (BEAS). Report 2: Head-On Impact with a Deformable BEAS and Introducing a Collapsible Arch

    DTIC Science & Technology

    2011-07-01

    gate operations at Belleville Locks and Dam. ........................... 105 Figure 5.20 The non-linear costs for full closure of the locks and dam...Super Cone Fender Front Arch Results ................................................. 96 Table 5.3 Costs Over Time for Full Closure at Particular Corps...Corps Navigation Economics PDT tabulation of costs over time for full closure at the Corps lock and dam structures. Bob Willis also supplied the

  8. 40 CFR 265.112 - Closure plan; amendment of plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... residues and contaminated containment system components, equipment, structures, and soils during partial... contaminated soils, methods for sampling and testing surrounding soils, and criteria for determining the extent of decontamination necessary to satisfy the closure performance standard; and (5) A detailed...

  9. 40 CFR 264.112 - Closure plan; amendment of plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... residues and contaminated containment system components, equipment, structures, and soils during partial... contaminated soils, methods for sampling and testing surrounding soils, and criteria for determining the extent of decontamination required to satisfy the closure performance standard; and (5) A detailed...

  10. 40 CFR 264.178 - Closure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Closure. 264.178 Section 264.178 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR... from the containment system. Remaining containers, liners, bases, and soil containing or contaminated...

  11. 40 CFR 265.228 - Closure and post-closure care.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 265.228 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... or operator must: (1) Remove or decontaminate all waste residues, contaminated containment system...

  12. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.

    PubMed

    McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J

    2014-01-01

    A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P < .01). At follow-up (median, 312 days; range, 0-1429 days), the mean aortic insufficiency score remained low for the patients with central aortic valve closure (0.27 ± 0.46) in contrast to those without central aortic valve closure who experienced aortic insufficiency progression (0.78 ± 0.89; P = .02). In addition, the proportion of patients with more than mild aortic insufficiency was significantly less in the central aortic valve closure group (0% vs 18%; P = .05). The patients in the central aortic valve closure group were significantly older and had a greater incidence of renal failure at baseline. The 30-day mortality was greater in the central aortic valve closure group, but the late survival was similar between the 2 groups. No reoperations were required for recurrent aortic insufficiency. The results of our study have shown that repair of aortic insufficiency with a simple central coaptation stitch is effective and durable in left ventricular assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  13. Alterations of papilla dimensions after orthodontic closure of the maxillary midline diastema: a retrospective longitudinal study

    PubMed Central

    2016-01-01

    Purpose The aim of this study was to evaluate alterations of papilla dimensions after orthodontic closure of the diastema between maxillary central incisors. Methods Sixty patients who had a visible diastema between maxillary central incisors that had been closed by orthodontic approximation were selected for this study. Various papilla dimensions were assessed on clinical photographs and study models before the orthodontic treatment and at the follow-up examination after closure of the diastema. Influences of the variables assessed before orthodontic treatment on the alterations of papilla height (PH) and papilla base thickness (PBT) were evaluated by univariate regression analysis. To analyze potential influences of the 3-dimensional papilla dimensions before orthodontic treatment on the alterations of PH and PBT, a multiple regression model was formulated including the 3-dimensional papilla dimensions as predictor variables. Results On average, PH decreased by 0.80 mm and PBT increased after orthodontic closure of the diastema (P<0.01). Univariate regression analysis revealed that the PH (P=0.002) and PBT (P=0.047) before orthodontic treatment influenced the alteration of PH. With respect to the alteration of PBT, the diastema width (P=0.045) and PBT (P=0.000) were found to be influential factors. PBT before the orthodontic treatment significantly influenced the alteration of PBT in the multiple regression model. Conclusions PH decreased but PBT increased after orthodontic closure of the diastema. The papilla dimensions before orthodontic treatment influenced the alterations of PH and PBT after closure of the diastema. The PBT increased more when the diastema width before the orthodontic treatment was larger. PMID:27382507

  14. Outcomes of Percutaneous Closure of Patent Ductus Arteriosus Accompanied With Unilateral Absence of Pulmonary Artery.

    PubMed

    Yang, Yankun; Zheng, Hong; Xu, Zhongying; Zhang, Gejun; Jin, Jinglin; Hu, Haibo; Tian, Tao; Zhou, Xianliang

    2017-04-01

    Limited data have reported the outcomes of percutaneous closure of patent ductus arteriosus (PDA) in patients with unilateral absence of pulmonary artery (UAPA). This study aimed to evaluate the symptomatology, diagnosis and therapy, especially the transcatheter closure of PDA in patients with PDA associated with UAPA. Patients diagnosed with PDA and UAPA were retrospectively enrolled from August 2010 through January 2016. Clinical data, treatment and follow-up information were evaluated. Thirteen patients (6 males and 7 females) were diagnosed with PDA associated with UAPA. Percutaneous closure was successfully conducted in 6 patients successfully. The median age was 7 years (7 months to 37 years). The mean diameter of the PDA and occluders were 4.7 ± 1.8mm (2-7mm) and 11.3 ± 3.9mm (6-14mm), respectively. The mean pulmonary artery pressure was 41.5 ± 13.5mmHg (25-62mmHg). The diameter of PDA has no relationship with the degree of pulmonary artery pressure (r = 0.239, P = 0.648). In 4 patients, systolic pulmonary arterial pressure decreased significantly after closure with 69.0 ± 10.7 versus 48.0 ± 11.3mmHg (P = 0.146), and also the mean pulmonary arterial pressure was 54.5 ± 5.7 mm Hg versus 30.5 ± 3.9mmHg (P = 0.04). In all, 1 patient had a trace residual shunt, which disappeared within 24 hours. In appropriate patients with PDA associated with UAPA, transcatheter closure of PDA has the potential to improve the pulmonary artery hypertension. Further follow-up is required to monitor the long-term outcomes. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  15. An evaluation of oxygen-hydrogen propulsion systems for the Space Station

    NASA Technical Reports Server (NTRS)

    Klemetson, R. W.; Garrison, P. W.; Hannum, N. P.

    1985-01-01

    Conceptual designs for O2/H2 chemical and resistojet propulsion systems for the space station was developed and evaluated. The evolution of propulsion requirements was considered as the space station configuration and its utilization as a space transportation node change over the first decade of operation. The characteristics of candidate O2/H2 auxiliary propulsion systems are determined, and opportunities for integration with the OTV tank farm and the space station life support, power and thermal control subsystems are investigated. OTV tank farm boiloff can provide a major portion of the growth station impulse requirements and CO2 from the life support system can be a significant propellant resource, provided it is not denied by closure of that subsystem. Waste heat from the thermal control system is sufficient for many propellant conditioning requirements. It is concluded that the optimum level of subsystem integration must be based on higher level space station studies.

  16. Application of the E - Turbulence Closure Model to the Neutral and Stable Atmospheric Boundary Layer.

    NASA Astrophysics Data System (ADS)

    Duynkerke, P. G.

    1988-03-01

    In the E - turbulence model an eddy-exchange coefficient is evaluated from the turbulent kinetic energy E and viscous dissipation . In this study we will apply the E - model to the stable and neutral atmospheric boundary layer. A discussion is given on the equation for , which terms should be included and how we have evaluated the constants. Constant cooling rate results for the stable atmospheric boundary layer are compared with a second-order closure study. For the neutral atmospheric boundary layer a comparison is made with observations, large-eddy simulations and a second-order closure study. It is shown that a small stability effect can change the neutral atmospheric boundary layer quite drastically, and therefore, it will be difficult to observe a neutral boundary layer in the atmosphere.

  17. Secure closure of the tracheal incision after natural orifice transluminal endoscopic surgery with a surgical sealant (CoSeal).

    PubMed

    Liu, Yun-Hen; Wu, Yi-Cheng; Chen, Tzu-Ping; Ko, Po-Jen

    2011-09-01

    To evaluate the effectiveness of surgical sealant (CoSeal) in sealing the tracheal assess sites after transtracheal thoracoscopy. Two dogs underwent transtracheal thoracic exploration and pericardial window creation. The thoracic cavity was approached with flexible bronchoscope through a 9-mm tracheal incision. The pericardial window was performed with a needle knife via the working channel of the bronchoscope, and the tracheal assess site was closed with CoSeal using a rubber catheter. The integrity of tracheal healing was evaluated under positive pressure ventilation. Transtracheal creation of pericardial window and closure of tracheal incision with CoSeal was successfully performed in both dogs. There was no evidence of air leaks from the chest tube during positive pressure ventilation. Autopsy revealed no injury to the mediastinum and intrathoracic structure. Endoscopic closure of tracheal access site of NOTES with CoSeal appears to be a feasible technique.

  18. Evaluating Rifean Corridor Closure using Detrital Zircon Sediment Provenance of the Taza-Guercif Basin, Morocco

    NASA Astrophysics Data System (ADS)

    Pratt, J. R.; Barbeau, D. L.; Emran, A.

    2013-12-01

    In the late Miocene, the connection between the Mediterranean Sea and Atlantic Ocean was tectonically severed leading to severe evaporative draw down of Mediterranean sea level such that the entire basin was desiccated or near desiccated in an event from ~5.96-5.33 Ma known as the Messinian Salinity Crisis (MSC). The MSC sequestered 6% of global ocean salinity into evaporite deposits, created a deep, dry and hot basin that altered global atmospheric circulation, opened passageways for mammal migration between Europe, Africa and Arabia and ended in the largest flood observed in the geologic record. The combined effects of the Messinian Salinity Crisis make it the most important oceanic event in the last 20 million years, yet despite the dramatic ramifications of the MSC, the exact nature of its cause has remained both elusive and controversial. By examining the sedimentary provenance of Rifean Corridor, this research evaluates the progression of corridor closure and the tectonic context of the initiation of the Messinian Salinity Crisis. The difficulty in evaluating the progression of closure is due to the tectonic complexity of the Africa-Eurasia convergent plate boundary in north-central Morocco. The shortening associated with the tectonic convergence is accommodated by two genetically and tectonically distinct orogenic systems, the Rif and Atlas mountain belts, which lie in juxtaposition to the slab-rollback dominated Alboran Sea. The basins of the Rifean corridor lie between these two orogens and as such shortening and uplift associated with either or both ranges could be the cause of the corridor closure. Several hypotheses have been posited for the tectonic controls on basin emergence including slab-rollback related delamination on the Alboran margin, domal uplift of the Middle Atlas as well as a more traditional propagation of the Rifean orogenic wedge. This research provides the first quantitative provenance data for the Taza-Guercif basin in the form of LA-ICP-MS detrital zircon analysis of 10 samples from the basin-fill and 3 samples from two separate domains within the Rif. The new data reveal a lack of dramatic shifts in provenance within the basin-fill tied to corridor closure but instead reveal more subtle changes in peak zircon ages. Peak age shifts from 600 Ma to 700 Ma periodically within the strata in both open marine marls and within turbidites derived from the Middle Atlas in a pattern consistent with changes in basin bathymetry. Basin samples show an age-distribution consistent with the Rifean samples, which acquire an slight overprinting of Middle Atlas ages in the latter half of the succession. The data point to a progressive closure of the corridor through the advancement of the Rifean orogenic wedge with minor influence from uplift within the core of the Middle Atlas without a major shift in provenance during rapid basin emergence.

  19. Closure Report for Corrective Action Unit 573: Alpha Contaminated Sites Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, Patrick

    This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 573: Alpha Contaminated Sites, Nevada National Security Site, Nevada. CAU 573 comprises the two corrective action sites (CASs): 05-23-02-GMX Alpha Contaminated Are-Closure in Place and 05-45-01-Atmospheric Test Site - Hamilton- Clean Closure. The purpose of this CR is to provide justification and documentation supporting the recommendation that no further corrective action is needed for CAU 573 based on the implementation of the corrective actions. Corrective action activities were performed at Hamilton from May 25 through June 30, 2016; and at GMX from May 25 to Octobermore » 27, 2016, as set forth in the Corrective Action Decision Document (CADD)/Corrective Action Plan (CAP) for Corrective Action Unit 573: Alpha Contaminated Sites; and in accordance with the Soils Activity Quality Assurance Plan, which establishes requirements, technical planning, and general quality practices. Verification sample results were evaluated against data quality objective criteria developed by stakeholders that included representatives from the Nevada Division of Environmental Protection and the DOE, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) during the corrective action alternative (CAA) meeting held on November 24, 2015. Radiological doses exceeding the final action level were assumed to be present within the high contamination areas associated with CAS 05-23-02, thus requiring corrective action. It was also assumed that radionuclides were present at levels that require corrective action within the soil/debris pile associated with CAS 05-45-01. During the CAU 573 CAA meeting, the CAA of closure in place with a use restriction (UR) was selected by the stakeholders as the preferred corrective action of the high contamination areas at CAS 05-23-02 (GMX), which contain high levels of removable contamination; and the CAA of clean closure was selected by the stakeholders as preferred corrective action for the debris pile at CAS 05-45-01 (Hamilton). The closure in place was accomplished by posting signs containing a warning label on the existing contamination area fence line; and recording the FFACO UR and administrative UR in the FFACO database, the NNSA/NFO CAU/CAS files, and the management and operating contractor Geographic Information Systems. The clean closure was accomplished by excavating the soil/debris pile, disposing of the contents at the Area 5 Radioactive Waste Management Complex, and collecting verification samples. The corrective actions were implemented as stipulated in the CADD/CAP, and verification sample results confirm that the criteria for the completion of corrective actions have been met. Based on the implementation of these corrective actions, NNSA/NFO provides the following recommendations: No further corrective actions are necessary for CAU 573; The Nevada Division of Environmental Protection should issue a Notice of Completion to NNSA/NFO for closure of CAU 573; CAU 573 should be moved from Appendix III to Appendix IV of the FFACO.« less

  20. Electrical velocimetry for non-invasive monitoring of the closure of the ductus arteriosus in preterm infants.

    PubMed

    Rodríguez Sánchez de la Blanca, Ana; Sánchez Luna, M; González Pacheco, N; Arriaga Redondo, M; Navarro Patiño, N

    2018-02-01

    Closure of a patent ductus arteriosus (PDA) in preterm infants modifies cardiac output and induces adaptive changes in the hemodynamic situation. The present study aims to analyze those changes, through a non-invasive cardiac output monitor based on blood electrical velocimetry, in preterm babies. A prospective observational study of preterm infants with a gestational age of less than 28 weeks, and a hemodynamic significant PDA, requires intravenous ibuprofen or surgical closure. All patients were monitored with electrical velocimetry before treatment and through the following 72 h. Two groups were defined, ibuprofen and surgical closure. Variations of cardiac output were analyzed from the basal situation and at 1, 8, 24, 48, and 72 h on each group. During a 12-month period, 18 patients were studied. The median gestational age in the ibuprofen group (12/18) was 26 +5  weeks (25 +5 -27 +3 ) with a median birth weight of 875 (670-1010) g. The cardiac output index (CI) value was 0.29 l/kg/min (0.24-0.34). Among the patients with confirmed ductus closure (50%), a significant CI decrease was shown (0.24 vs 0.29 l/kg/min; P 0.03) after 72 h (three ibuprofen doses). A statistically significant decrease in systolic volume (SVI) was found: 1.62 vs 1.88 ml/kg, P 0.03 with a decrease in contractility (ICON), 85 vs 140, P 0.02. The gestational age in the surgical group (6/18) was 25 +2  weeks (24-26 +3 ) with a median weight of 745 (660-820) g. All patients in this group showed a decrease in the immediate postoperative CI (1 h after surgery) 0.24 vs 0.30 l/kg/min, P 0.05, and a significant decrease in contractility (ICON 77 vs 147, P 0.03). In addition, a no statistically significant decrease in SVI (1.54 vs 1.83 ml/kg, P 0.06), as well as an increase in systemic vascular resistance (10,615 vs 8797 dyn/cm 2 , P 0.08), were detected. This deterioration was transient without significant differences in the remaining periods of time evaluated. The surgical closure of the PDA in preterm infants causes a transient deterioration of cardiac function linked to a documented decrease in the left ventricular output. The hemodynamic changes detected after pharmacological PDA closure are similar but those patients present a better clinical tolerance to changes in the cardiac output. What is Known: • Surgical ductus closure generates acute hemodynamic changes in cardiac output and left ventricular function. What is New: • The hemodynamic changes detected after pharmacological ductus closure are similar to those found in the surgical closure. Electrical velocimetry can detect those changes.

  1. Evaluation of age determination techniques for gray wolves

    USGS Publications Warehouse

    Landon, D.B.; Waite, C.A.; Peterson, R.O.; Mech, L.D.

    1998-01-01

    We evaluated tooth wear, cranial suture fusion, closure of the canine pulp cavity, and cementum annuli as methods of age determination for known- and unknown-age gray wolves (Canis lupus) from Alaska, Minnesota, Ontario, and Isle Royale, Michigan. We developed age classes for cranial suture closure and tooth wear. We used measurement data obtained from known-age captive and wild wolves to generate a regression equation to predict age based on the degree of closure of the canine pulp cavity. Cementum annuli were studied in known- and unknown-age animals, and calcified, unstained thin sections were found to provide clear annulus patterns under polarized transmitted light. Annuli counts varied among observers, partly because of variation in the pattern of annuli in different regions of the cementum. This variation emphasizes the need for standardized models of cementum analysis. Cranial suture fusion is of limited utility in age determination, while tooth wear can be used to estimate age of adult wolves within 4 years. Wolves lt 7 years old could be aged to within 13 years with the regression equation for closure of the canine pulp cavity. Although inaccuracy remains a problem, cementum-annulus counts were the most promising means of estimating age for gray wolves.

  2. Influence of Different Container Closure Systems and Capping Process Parameters on Product Quality and Container Closure Integrity (CCI) in GMP Drug Product Manufacturing.

    PubMed

    Mathaes, Roman; Mahler, Hanns-Christian; Roggo, Yves; Huwyler, Joerg; Eder, Juergen; Fritsch, Kamila; Posset, Tobias; Mohl, Silke; Streubel, Alexander

    2016-01-01

    Capping equipment used in good manufacturing practice manufacturing features different designs and a variety of adjustable process parameters. The overall capping result is a complex interplay of the different capping process parameters and is insufficiently described in literature. It remains poorly studied how the different capping equipment designs and capping equipment process parameters (e.g., pre-compression force, capping plate height, turntable rotating speed) contribute to the final residual seal force of a sealed container closure system and its relation to container closure integrity and other drug product quality parameters. Stopper compression measured by computer tomography correlated to residual seal force measurements.In our studies, we used different container closure system configurations from different good manufacturing practice drug product fill & finish facilities to investigate the influence of differences in primary packaging, that is, vial size and rubber stopper design on the capping process and the capped drug product. In addition, we compared two large-scale good manufacturing practice manufacturing capping equipment and different capping equipment settings and their impact on product quality and integrity, as determined by residual seal force.The capping plate to plunger distance had a major influence on the obtained residual seal force values of a sealed vial, whereas the capping pre-compression force and the turntable rotation speed showed only a minor influence on the residual seal force of a sealed vial. Capping process parameters could not easily be transferred from capping equipment of different manufacturers. However, the residual seal force tester did provide a valuable tool to compare capping performance of different capping equipment. No vial showed any leakage greater than 10(-8)mbar L/s as measured by a helium mass spectrometry system, suggesting that container closure integrity was warranted in the residual seal force range tested for the tested container closure systems. Capping equipment used in good manufacturing practice manufacturing features different designs and a variety of adjustable process parameters. The overall capping result is a complex interplay of the different capping process parameters and is insufficiently described in the literature. It remains poorly studied how the different capping equipment designs and capping equipment process parameters contribute to the final capping result.In this study, we used different container closure system configurations from different good manufacturing process drug product fill & finish facilities to investigate the influence of the vial size and the rubber stopper design on the capping process. In addition, we compared two examples of large-scale good manufacturing process capping equipment and different capping equipment settings and their impact on product quality and integrity, as determined by residual seal force. © PDA, Inc. 2016.

  3. Results from extrapleural clipping of a patent ductus arteriosus in seriously ill preterm infants.

    PubMed

    Demirturk, Orhan; Güvener, Murat; Coşkun, Isa; Tünel, Hüseyin Ali

    2011-12-01

    Minithoracotomy for extrapleural closure of the patent ductus arteriosus (PDA) in seriously ill patients offers a fast and less invasive alternative to conventional transpleural ductal closure. This study reports the immediate postoperative clinical outcomes for 24 extrapleurally clipped premature infants presenting with congestive heart failure in high-risk comorbidity status between March 2007 and November 2010. The demographics, preoperative clinical characteristics, and postoperative outcomes of the patients, including echocardiographic assessments, were evaluated. No surgery-related mortalities occurred. Four mortalities occurred after surgery due to sepsis and bleeding diathesis. All 20 surviving patients exhibited normal left ventricular dimensions and systolic function in the immediate follow-up period. The study shows that extrapleural clip closure in seriously ill premature infants has an acceptable overall short-term mortality and complication rate with a high rate of ductal closure.

  4. Variability in school closure decisions in response to 2009 H1N1: a qualitative systems improvement analysis

    PubMed Central

    2011-01-01

    Background School closure was employed as a non-pharmaceutical intervention against pandemic 2009 H1N1, particularly during the first wave. More than 700 schools in the United States were closed. However, closure decisions reflected significant variation in rationales, decision triggers, and authority for closure. This variability presents the opportunity for improved efficiency and decision-making. Methods We identified media reports relating to school closure as a response to 2009 H1N1 by monitoring high-profile sources and searching Lexis-Nexis and Google news alerts, and reviewed reports for key themes. News stories were supplemented by observing conference calls and meetings with health department and school officials, and by discussions with decision-makers and community members. Results There was significant variation in the stated goal of closure decision, including limiting community spread of the virus, protecting particularly vulnerable students, and responding to staff shortages or student absenteeism. Because the goal of closure is relevant to its timing, nature, and duration, unclear rationales for closure can challenge its effectiveness. There was also significant variation in the decision-making authority to close schools in different jurisdictions, which, in some instances, was reflected in open disagreement between school and public health officials. Finally, decision-makers did not appear to expect the level of scientific uncertainty encountered early in the pandemic, and they often expressed significant frustration over changing CDC guidance. Conclusions The use of school closure as a public health response to epidemic disease can be improved by ensuring that officials clarify the goals of closure and tailor closure decisions to those goals. Additionally, authority to close schools should be clarified in advance, and decision-makers should expect to encounter uncertainty disease emergencies unfold and plan accordingly. PMID:21284865

  5. Automated method for determining Instron Residual Seal Force of glass vial/rubber closure systems. Part II. 13 mm vials.

    PubMed

    Ludwig, J D; Davis, C W

    1995-01-01

    Instron Residual Seal Force (IRSF) of 13 mm glass vial/rubber closure systems was determined using an Instron 4501 Materials Testing System and computerized data analysis. A series of three cap anvils varying in shape and dimensions were machined to optimize cap anvil performance. Cap anvils with spherical top surfaces and narrow internal dimensions produced uniform stress-deformation curves from which precise IRSF values were derived.

  6. Experiences with welding multi-assembly sealed baskets at Palisades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agace, S.; Worrell, S.; Stewart, L.

    1995-12-01

    Four utilities were using operational canister-based dry storage facilities at year-end, and seven more have contracts to establish similar facilities. Consumers Power`s Palisades Nuclear Power Plant has successfully completed loading its eighth dry storage canister with the Ventilated Storage Cask (VSC) system, under license to Sierra Nuclear Corporation. The VSC has a Multi-Assembly Sealed Basket (MSB) containing 24 specially-selected and aged spent fuel assemblies. MSB closure occurs when two independent lids are welded at the utility. The canister wall and lids are SA-516 Grade 70 carbon steel. This paper discusses the welding system design, closure operations and MSB closure operationsmore » at Palisades.« less

  7. Evaluation and development plan of NRTA measurement methods for the Rokkasho Reprocessing Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, T.K.; Hakkila, E.A.; Flosterbuer, S.F.

    Near-real-time accounting (NRTA) has been proposed as a safeguards method at the Rokkasho Reprocessing Plant (RRP), a large-scale commercial boiling water and pressurized water reactors spent-fuel reprocessing facility. NRTA for RRP requires material balance closures every month. To develop a more effective and practical NRTA system for RRP, we have evaluated NRTA measurement techniques and systems that might be implemented in both the main process and the co-denitration process areas at RRP to analyze the concentrations of plutonium in solutions and mixed oxide powder. Based on the comparative evaluation, including performance, reliability, design criteria, operation methods, maintenance requirements, and estimatedmore » costs for each possible measurement method, recommendations for development were formulated. This paper discusses the evaluations and reports on the recommendation of the NRTA development plan for potential implementation at RRP.« less

  8. Short-term safety and efficacy of left atrial appendage closure with the WATCHMAN device in patients with small left atrial appendage ostia.

    PubMed

    Venkataraman, Ganesh; Strickberger, S Adam; Doshi, Shephal; Ellis, Christopher R; Lakkireddy, Dhanunjaya; Whalen, S Patrick; Cuoco, Frank

    2018-01-01

    Left atrial appendage (LAA) closure with the WATCHMAN device, according to FDA labelling, is recommended in patients with a maximal LAA ostial width between 17 and 31 mm. The safety and efficacy of LAA closure in patients with a maximal LAA ostial width < 17 mm has not been evaluated. The goal of this study was to determine the acute and short-term safety and efficacy of LAA closure with the WATCHMAN device in patients with a maximal LAA ostial width < 17 mm. Thirty-two consecutive patients with a maximal LAA ostial width < 17 mm as determined by a screening transesophageal echocardiogram (TEE) underwent LAA closure with the WATCHMAN device between March 2015 and November 2016 at five medical centers, and were included in this study. Mean age, body mass index (BMI), and CHA 2 DS 2 -VASC score were 70.8 ± 8.6 years, 29.3 ± 6.5 kg/m 2 , and 3.9 ±1.2, respectively. At the screening TEE, mean maximal LAA ostial width and depth were 15.6 ± 0.6 mm (range 14-16) and 23.2 ± 4.5 mm (range 13-31), respectively. Successful LAA closure with the WATCHMAN device was achieved in 31 of 32 patients (97%), with no major complications. TEE performed 45 days after LAA closure demonstrated no peridevice leak > 5 mm and no device related thrombi. Warfarin was discontinued in all 31 patients 45 days after LAA closure. LAA closure with the WATCHMAN device can be successfully and safely achieved in patients with a maximal LAA ostial width < 17 mm. © 2017 Wiley Periodicals, Inc.

  9. Transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of perimembranous ventricular septal defects in children: a protocol for a network meta-analysis.

    PubMed

    You, Tao; Yi, Kang; Ding, Zhao-Hong; Hou, Xiao-Dong; Liu, Xing-Guang; Wang, Xin-Kuan; Ge, Long; Tian, Jin-Hui

    2017-06-21

    Both transcatheter device closure and surgical repair are effective treatments with excellent midterm outcomes for perimembranous ventricular septal defects (pmVSDs) in children. The mini-invasive periventricular device occlusion technique has become prevalent in research and application, but evidence is limited for the assessment of transcatheter closure, mini-invasive closure and open-heart surgical repair. This study comprehensively compares the efficacy, safety and costs of transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of pmVSDs in children using Bayesian network meta-analysis. A systematic search will be performed using Chinese Biomedical Literature Database, China National Knowledge Infrastructure, PubMed, EMBASE.com and the Cochrane Central Register of Controlled Trials to include random controlled trials, prospective or retrospective cohort studies comparing the efficacy, safety and costs of transcatheter closure, mini-invasive closure and open-heart surgical repair. The risk of bias for the included prospective or retrospective cohort studies will be evaluated according to the risk of bias in non-randomised studies of interventions (ROBINS-I). For random controlled trials, we will use risk of bias tool from Cochrane Handbook version 5.1.0. A Bayesian network meta-analysis will be conducted using R-3.3.2 software. Ethical approval and patient consent are not required since this study is a network meta-analysis based on published trials. The results of this network meta-analysis will be submitted to a peer-reviewed journal for publication. CRD42016053352. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Transcatheter Closure of Patent Foramen Ovale: A Single Center Experience.

    PubMed

    Milev, Ivan; Zafirovska, Planinka; Zimbakov, Zan; Idrizi, Shpend; Ampova-Sokolov, Vilma; Gorgieva, Emilija; Ilievska, Liljana; Tosheski, Goce; Hristov, Nikola; Georgievska-Ismail, Ljubica; Anguseva, Tanja; Mitrev, Zan

    2016-12-15

    Percutaneous transcatheter closure (PTC) of patent foramen ovale (PFO) is implicated in cryptogenic stroke, transitional ischemic attack (TIA) and treatment of a migraine. Our goal was to present our experience in the interventional treatment of PFO, as well as to evaluate the short and mid-term results in patients with closed PFO. Transcatheter closure of PFO was performed in 52 patients (67.3% women, mean age 40.7 ± 11.7 years). Patients were interviewed for subjective grading of the intensity of headaches before and after the PFO closure. During 2 years of follow-up, there was no incidence of new stroke, TIA and/or syncope. Follow-up TCD performed in 35 patients showed complete PFO closure in 20 patients (57.1%). Out of 35 patients, 22 (62.9%) reported having a migraine before the procedure with an intensity of headaches at 8.1 ± 1.9 on a scale from 1 to 10. During 2 years of follow-up, symptoms of a migraine disappeared in 4 (18.2%) and the remaining 18 patients reported the significant decrease in intensity 4.8 ± 2.04 (p = 0.0001). In addition, following PFO closure the incidence of the headaches decreased significantly (p = 0.0001). Percutaneous transcatheter closure of PFO is a safe and effective procedure showing mid-term relief of neurological symptoms in patients as well as significant reduction of migraine symptoms.

  11. Surgical outcomes after application of a liquid adhesive ocular bandage to clear corneal incisions during cataract surgery.

    PubMed

    Uy, Harvey S; Kenyon, Kenneth R

    2013-11-01

    To compare the anatomic and refractive outcomes in eyes having phacoemulsification with 1 of 3 clear corneal incision (CCI) closure methods. Ambulatory surgical center, Makati, Philippines. Prospective randomized clinical trial. Patients having phacoemulsification cataract surgery had wound closure using no additional treatment (control), a single 10-0 nylon suture, or a liquid adhesive ocular bandage (Ocuseal). The main outcome measures were wound-edge closure rates, surgically induced astigmatism (SIA), foreign-body sensation, and intraocular pressure (IOP) 1, 3, 5, 7, and 14 days postoperatively. The study evaluated 90 eyes. There was a significant improvement in wound-edge closure rates in the suture group and the ocular bandage group compared with the control group (P<.001). A significant increase in SIA occurred in the sutured group but not in the control or ocular bandage groups (P<.001). The ocular bandage group had significantly less foreign-body sensation than the control and suture groups (P<.001). There were no significant differences in IOP between the groups (P=.515). The liquid adhesive ocular bandage resulted in improved wound-edge closure, reduced SIA, and diminished foreign-body sensation. Suturing was associated with improved wound-edge closure but increased SIA and foreign-body sensation. Unsutured incisions led to delayed wound-edge closure and increased foreign-body sensation. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Transcatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.

    PubMed

    Djer, Mulyadi M; Idris, Nikmah S; Alwi, Idrus; Wijaya, Ika P

    2014-07-01

    Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the most appropriate technique and device. We would like to report a case of transcatheter closure of residual VSD post Rastelli operation in a patient with double outlet right ventricle (DORV), sub-aortic VSD, severe infundibulum pulmonary stenosis (PS) and single coronary artery. The patient had undergone operations for four times, but he still had intractable heart failure that did not response to medications. On the first attempt. we closed the VSD using a VSD occluder, unfortunately the device embolized into the descending aorta, but fortunately we was able to snare it out. Then we decided to close the VSD using a patent ductus arteriosus (PDA occluder). On transesophageal echocardiography (TEE) and angiography evaluation, the device position was stable. Post transcatheter VSD closure, the patient clinical condition improved significantly and he could finally be discharged after a long post-surgery hospitalization. Based on this experience we concluded that the transcatheter closure of residual VSD in complex CHD using PDA occluder could be an effective alternative treatment.

  13. The impact of rural hospital closures on equity of commuting time for haemodialysis patients: simulation analysis using the capacity-distance model.

    PubMed

    Matsumoto, Masatoshi; Ogawa, Takahiko; Kashima, Saori; Takeuchi, Keisuke

    2012-07-23

    Frequent and long-term commuting is a requirement for dialysis patients. Accessibility thus affects their quality of lives. In this paper, a new model for accessibility measurement is proposed in which both geographic distance and facility capacity are taken into account. Simulation of closure of rural facilities and that of capacity transfer between urban and rural facilities are conducted to evaluate the impacts of these phenomena on equity of accessibility among dialysis patients. Post code information as of August 2011 of all the 7,374 patients certified by municipalities of Hiroshima prefecture as having first or third grade renal disability were collected. Information on post code and the maximum number of outpatients (capacity) of all the 98 dialysis facilities were also collected. Using geographic information systems, patient commuting times were calculated in two models: one that takes into account road distance (distance model), and the other that takes into account both the road distance and facility capacity (capacity-distance model). Simulations of closures of rural and urban facilities were then conducted. The median commuting time among rural patients was more than twice as long as that among urban patients (15 versus 7 minutes, p<0.001). In the capacity-distance model 36.1% of patients commuted to the facilities which were different from the facilities in the distance model, creating a substantial gap of commuting time between the two models. In the simulation, when five rural public facilitiess were closed, Gini coefficient of commuting times among the patients increased by 16%, indicating a substantial worsening of equity, and the number of patients with commuting times longer than 90 minutes increased by 72 times. In contrast, closure of four urban public facilities with similar capacities did not affect these values. Closures of dialysis facilities in rural areas have a substantially larger impact on equity of commuting times among dialysis patients than closures of urban facilities. The accessibility simulations using the capacity-distance model will provide an analytic framework upon which rational resource distribution policies might be planned.

  14. The impact of rural hospital closures on equity of commuting time for haemodialysis patients: simulation analysis using the capacity-distance model

    PubMed Central

    2012-01-01

    Background Frequent and long-term commuting is a requirement for dialysis patients. Accessibility thus affects their quality of lives. In this paper, a new model for accessibility measurement is proposed in which both geographic distance and facility capacity are taken into account. Simulation of closure of rural facilities and that of capacity transfer between urban and rural facilities are conducted to evaluate the impacts of these phenomena on equity of accessibility among dialysis patients. Methods Post code information as of August 2011 of all the 7,374 patients certified by municipalities of Hiroshima prefecture as having first or third grade renal disability were collected. Information on post code and the maximum number of outpatients (capacity) of all the 98 dialysis facilities were also collected. Using geographic information systems, patient commuting times were calculated in two models: one that takes into account road distance (distance model), and the other that takes into account both the road distance and facility capacity (capacity-distance model). Simulations of closures of rural and urban facilities were then conducted. Results The median commuting time among rural patients was more than twice as long as that among urban patients (15 versus 7 minutes, p < 0.001). In the capacity-distance model 36.1% of patients commuted to the facilities which were different from the facilities in the distance model, creating a substantial gap of commuting time between the two models. In the simulation, when five rural public facilitiess were closed, Gini coefficient of commuting times among the patients increased by 16%, indicating a substantial worsening of equity, and the number of patients with commuting times longer than 90 minutes increased by 72 times. In contrast, closure of four urban public facilities with similar capacities did not affect these values. Conclusions Closures of dialysis facilities in rural areas have a substantially larger impact on equity of commuting times among dialysis patients than closures of urban facilities. The accessibility simulations using thecapacity-distance model will provide an analytic framework upon which rational resource distribution policies might be planned. PMID:22824294

  15. International consensus conference on open abdomen in trauma.

    PubMed

    Chiara, Osvaldo; Cimbanassi, Stefania; Biffl, Walter; Leppaniemi, Ari; Henry, Sharon; Scalea, Thomas M; Catena, Fausto; Ansaloni, Luca; Chieregato, Arturo; de Blasio, Elvio; Gambale, Giorgio; Gordini, Giovanni; Nardi, Guiseppe; Paldalino, Pietro; Gossetti, Francesco; Dionigi, Paolo; Noschese, Giuseppe; Tugnoli, Gregorio; Ribaldi, Sergio; Sgardello, Sebastian; Magnone, Stefano; Rausei, Stefano; Mariani, Anna; Mengoli, Francesca; di Saverio, Salomone; Castriconi, Maurizio; Coccolini, Federico; Negreanu, Joseph; Razzi, Salvatore; Coniglio, Carlo; Morelli, Francesco; Buonanno, Maurizio; Lippi, Monica; Trotta, Liliana; Volpi, Annalisa; Fattori, Luca; Zago, Mauro; de Rai, Paolo; Sammartano, Fabrizio; Manfredi, Roberto; Cingolani, Emiliano

    2016-01-01

    A part of damage-control laparotomy is to leave the fascial edges and the skin open to avoid abdominal compartment syndrome and allow further explorations. This condition, known as open abdomen (OA), although effective, is associated with severe complications. Our aim was to develop evidence-based recommendations to define indications for OA, techniques for temporary abdominal closure, management of enteric fistulas, and methods of definitive wall closure. The literature from 1990 to 2014 was systematically screened according to PRISMA [Preferred Reporting Items for Systematic Reviews and Meta-analyses] protocol. Seventy-six articles were reviewed by a panel of experts to assign grade of recommendations (GoR) and level of evidence (LoE) using the GRADE [Grading of Recommendations Assessment, Development, and Evaluation] system, and an international consensus conference was held. OA in trauma is indicated at the end of damage-control laparotomy, in the presence of visceral swelling, for a second look in vascular injuries or gross contamination, in the case of abdominal wall loss, and if medical treatment of abdominal compartment syndrome has failed (GoR B, LoE II). Negative-pressure wound therapy is the recommended temporary abdominal closure technique to drain peritoneal fluid, improve nursing, and prevent fascial retraction (GoR B, LoE I). Lack of OA closure within 8 days (GoR C, LoE II), bowel injuries, high-volume replacement, and use of polypropylene mesh over the bowel (GoR C, LoE I) are risk factors for frozen abdomen and fistula formation. Negative-pressure wound therapy allows to isolate the fistula and protect the surrounding tissues from spillage until granulation (GoR C, LoE II). Correction of fistula is performed after 6 months to 12 months. Definitive closure of OA has to be obtained early (GoR C, LoE I) with direct suture, traction devices, component separation with or without mesh. Biologic meshes are an option for wall reinforcement if bacterial contamination is present (GoR C, LoE II). OA and negative-pressure techniques improve the care of trauma patients, but closure must be achieved early to avoid complications.

  16. A mixed fluid-kinetic solver for the Vlasov-Poisson equations

    NASA Astrophysics Data System (ADS)

    Cheng, Yongtao

    Plasmas are ionized gases that appear in a wide range of applications including astrophysics and space physics, as well as in laboratory settings such as in magnetically confined fusion. There are two prevailing types of modeling strategies to describe a plasma system: kinetic models and fluid models. Kinetic models evolve particle probability density distributions (PDFs) in phase space, which are accurate but computationally expensive. Fluid models evolve a small number of moments of the distribution function and reduce the dimension of the solution. However, some approximation is necessary to close the system, and finding an accurate moment closure that correctly captures the dynamics away from thermodynamic equilibrium is a difficult and still open problem. The main contributions of the present work can be divided into two main parts: (1) a new class of moment closures, based on a modification of existing quadrature-based moment-closure methods, is developed using bi-B-spline and bi-bubble representations; and (2) a novel mixed solver that combines a fluid and a kinetic solver is proposed, which uses the new class of moment-closure methods described in the first part. For the newly developed quadrature-based moment-closure based on bi-B-spline and bi-bubble representation, the explicit form of flux terms and the moment-realizability conditions are given. It is shown that while the bi-delta system is weakly hyperbolic, the newly proposed fluid models are strongly hyperbolic. Using a high-order Runge-Kutta discontinuous Galerkin method together with Strang operator splitting, the resulting models are applied to the Vlasov-Poisson-Fokker-Planck system in the high field limit. In the second part of this work, results from kinetic solver are used to provide a corrected closure to the fluid model. This correction keeps the fluid model hyperbolic and gives fluid results that match the moments as computed from the kinetic solution. Furthermore, a prolongation operation based on the bi-bubble moment-closure is used to make the first few moments of the kinetic and fluid solvers match. This results in a kinetic solver that exactly conserves mass and total energy. This mixed fluid-kinetic solver is applied to standard test problems for the Vlasov-Poisson system, including two-stream-instability problem and Landau damping.

  17. 36 CFR 13.50 - Closure procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Section 13.50 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA General Provisions § 13.50 Closure procedures. (a) Authority. The... cultural or scientific values, subsistence uses, endangered or threatened species conservation, and other...

  18. Feasibility of lane closures using probe data : technical brief.

    DOT National Transportation Integrated Search

    2017-04-01

    This study developed an on-line system analysis tool called the Work Zone Interactive : Management Application - Planning (WIMAP-P), an easy-to-use and easy-to-learn tool for : predicting the traffic impact caused by work zone lane closures on freewa...

  19. Management of Abdominal Wounds in Thermally Injured Patients

    DTIC Science & Technology

    1982-01-01

    my judgment, immediate skin graft closure after 1963. excision of a large burn is similar to closure of a celiotomy in 8. Haxten, H.: The absorption of...Surg. Gynecol. Obstet., 129: preventing skin graft disruption in such cases. Rather than the 758-760, 1969. usual 4 to 5 days required for solid...closure: A tion is necessary to produce a near 100% take when skin graft systems approach. Am. J. Surg., 131: 476-480, 1976.15. Mayo, C. W., Lee, M. J

  20. Navier-Stokes computation of compressible turbulent flows with a second order closure

    NASA Technical Reports Server (NTRS)

    Dingus, C.; Kollmann, W.

    1991-01-01

    The objective was the development of a complete second order closure for wall bounded flows, including all components of the dissipation rate tensor and a numerical solution procedure for the resulting system of equations. The main topics discussed are the closure of the pressure correlations and the viscous destruction terms in the dissipation rate equations and the numerical solution scheme based on a block-tridiagonal solver for the nine equations required for the prediction of plane or axisymmetric flows.

  1. Left Atrial Appendage Eccentricity and Irregularity Are Associated With Residual Leaks After Percutaneous Closure.

    PubMed

    Rajwani, Adil; Shirazi, Masoumeh G; Disney, Patrick J S; Wong, Dennis T L; Teo, Karen S L; Delacroix, Sinny; Chokka, Ramesh G; Young, Glenn D; Worthley, Stephen G

    2015-12-01

    Predictors of residual leak following percutaneous LAA closure were evaluated. Left atrial appendage (LAA) closure aims to exclude this structure from the circulation, typically using a circular occluder. A noncircular orifice is frequently encountered however, and fibrous remodeling of the LAA in atrial fibrillation may restrict orifice deformation. Noncircularity may thus be implicated in the occurrence of residual leak despite an appropriately oversized device. Pre-procedural multislice computerized tomography was used to quantify LAA orifice eccentricity and irregularity. Univariate predictors of residual leak were identified with respect to the orifice, device, and relevant clinical variables, with the nature of any correlations then further evaluated. Eccentricity and irregularity indexes of the orifice in 31 individuals were correlated with residual leak even where the device was appropriately oversized. An eccentricity index of 0.15 predicted a residual leak with 85% sensitivity and 59% specificity. An irregularity index of 0.05 predicted a significant residual leak ≥3 mm with 100% sensitivity and 86% specificity. Orifice size, device size, degree of device oversize, left atrial volume, and pulmonary artery pressure were not predictors of residual leak. Eccentricity and irregularity of the LAA orifice are implicated in residual leak after percutaneous closure even where there is appropriate device over-size. Irregularity index in particular is a novel predictor of residual leak, supporting a closer consideration of orifice morphology before closure. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. A comparison of septal stapler to suture closure in septoplasty: a prospective, randomized trial evaluating the effect on operative time.

    PubMed

    Sowerby, Leigh J; Wright, Erin D

    2013-11-01

    Septoplasty requires coaptation of the mucosal flaps at the conclusion of the procedure; classically this is done with nasal packing. Quilting sutures provide a welcome alternative to packing, but can be time-consuming to place. A septal stapler has recently been developed that provides a rapid alternative to quilting sutures but the timesaving has not been quantified. This study was a prospective, randomized trial comparing a septal stapler to quilting suture for coaptation of mucosal flaps in septoplasty. After meeting inclusion criteria, patients underwent septoplasty and inferior turbinoplasty. The total operative time, surgical segment times, including time for closure was recorded. Preoperative and postoperative Nasal Obstruction Symptom Evaluation (NOSE) scores were recorded. A sample size of 16 was determined to detect a difference of 5 minutes in closure time. A total of 16 patients were enrolled in the study. The mean time for closure with septal stapler was 35 ± 22 seconds vs 7 minutes ± 1 minute 10 seconds for suture closure (p < 0.0001). The mean total operative time using the septal stapler was 28 minutes ± 6 minutes whereas 43 minutes ± 13 minutes was required for suture (p = 0.014). No difference in postoperative complications or mucosal healing was seen; preoperative and postoperative improvement in NOSE scores was comparable. Coaptation of the mucosal flaps in septoplasty with a septal stapler affords a timesaving in the operating room with no difference in operative outcome. © 2013 ARS-AAOA, LLC.

  3. Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes.

    PubMed

    Wong, Hon-Tym; Chua, Jocelyn L L; Sakata, Lisandro M; Wong, Melissa H Y; Aung, Han T; Aung, Tin

    2009-05-01

    To evaluate the effectiveness of slitlamp optical coherence tomography (SL-OCT) and Scanning Peripheral Anterior Chamber depth analyzer (SPAC) in detecting angle closure, using gonioscopy as the reference standard. A total of 153 subjects underwent gonioscopy, SL-OCT, and SPAC. The anterior chamber angle (ACA) was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen; with SL-OCT, closure was determined by contact between the iris and angle wall anterior to the scleral spur; and with SPAC by a numerical grade of 5 or fewer and/or a categorical grade of suspect or potential. A closed ACA was identified in 51 eyes with gonioscopy, 86 eyes with SL-OCT, and 61 eyes with SPAC (gonioscopy vs SL-OCT, P < .001; gonioscopy vs SPAC, P = .10; SL-OCT vs SPAC, P < .001; McNemar test). Of the 51 eyes with a closed ACA on gonioscopy, SL-OCT detected a closed ACA in 43, whereas SPAC identified 41 (P = .79). An open angle in all 4 quadrants was observed in 102 eyes with gonioscopy, but SL-OCT and SPAC identified 43 and 20 of these eyes, respectively, as having angle closure. The overall sensitivity and specificity for SL-OCT were 84% and 58% vs 80% and 80% for SPAC. Using gonioscopy as the reference, SL-OCT and SPAC showed good sensitivity for detecting eyes at risk of angle closure.

  4. Closure Report for Corrective Action Unit 568: Area 3 Plutonium Dispersion Sites Nevada National Security Site, Nevada, Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, Patrick

    The purpose of this CR is to provide documentation and justification that no further corrective action is needed for the closure of CAU 568 based on the implementation of corrective actions. This includes a description of closure activities that were performed and an evaluation of the verification data. The CAP (NNSA/NFO, 2016a) and ROTC-1 (NNSA/NFO, 2016c) provide information relating to the selection of CAAs and the reasoning behind their selection. The CADD (NNSA/NFO, 2015) identifies the release sites that require additional corrective action and presents information supporting the selection of CAAs.

  5. Ecological Data in Support of the Tank Closure and Waste Management Environmental Impact Statement. Part 2: Results of Spring 2007 Field Surveys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sackschewsky, Michael R.; Downs, Janelle L.

    2007-05-31

    This review provides an evaluation of potential impacts of actions that have been proposed under various alternatives to support the closure of the high level waste tanks on the Hanford Site. This review provides a summary of data collected in the field during the spring of 2007 at all of the proposed project sites within 200 East and 200 West Areas, and at sites not previously surveyed. The primary purpose of this review is to provide biological data that can be incorporated into or used to support the Tank Closure and Waste Management Environmental Impact Statement.

  6. Life Support Goals Including High Closure and Low Mass Should Be Reconsidered Using Systems Analysis

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2017-01-01

    Recycling space life support systems have been built and tested since the 1960s and have operated on the International Space Station (ISS) since the mid 2000s. The development of space life support has been guided by a general consensus focused on two important related goals, increasing system closure and reducing launch mass. High closure is achieved by recycling crew waste products such as carbon dioxide and condensed humidity. Recycling directly reduces the mass of oxygen and water for the crew that must be launched from Earth. The launch mass of life support can be further reduced by developing recycling systems with lower hardware mass and reduced power. The life support consensus has also favored using biological systems. The goal of increasing closure using biological systems suggests that food should be grown in space and that biological processors be used for air, water, and waste recycling. The goal of reducing launch mass led to use of Equivalent System Mass (ESM) in life support advocacy and technology selection. The recent consensus assumes that the recycling systems architecture developed in the 1960s and implemented on ISS will be used on all future long missions. NASA and other project organizations use the standard systems engineering process to guide hardware development. The systems process was used to develop ISS life support, but it has been less emphasized in planning future systems for the moon and Mars. Since such missions are far in the future, there has been less immediate need for systems engineering analysis to consider trade-offs, reliability, and Life Cycle Cost (LCC). Preliminary systems analysis suggests that the life support consensus concepts should be revised to reflect systems engineering requirements.

  7. Stomatal closure induced by phytosphingosine-1-phosphate and sphingosine-1-phosphate depends on nitric oxide and pH of guard cells in Pisum sativum.

    PubMed

    Puli, Mallikarjuna Rao; Rajsheel, Pidakala; Aswani, Vetcha; Agurla, Srinivas; Kuchitsu, Kazuyuki; Raghavendra, Agepati S

    2016-10-01

    Phyto-S1P and S1P induced stomatal closure in epidermis of pea ( Pisum sativum ) by raising the levels of NO and pH in guard cells. Phosphosphingolipids, such as phytosphingosine-1-phosphate (phyto-S1P) and sphingosine-1-phosphate (S1P), are important signaling components during drought stress. The biosynthesis of phyto-S1P or S1P is mediated by sphingosine kinases (SPHKs). Although phyto-S1P and S1P are known to be signaling components in higher plants, their ability to induce stomatal closure has been ambiguous. We evaluated in detail the effects of phyto-S1P, S1P and SPHK inhibitors on signaling events leading to stomatal closure in the epidermis of Pisum sativum. Phyto-S1P or S1P induced stomatal closure, along with a marked rise in nitric oxide (NO) and cytoplasmic pH of guard cells, as in case of ABA. Two SPHK inhibitors, DL-threo dihydrosphingosine and N',N'-dimethylsphingosine, restricted ABA-induced stomatal closure and prevented the increase of NO or pH by ABA. Modulators of NO or pH impaired both stomatal closure and increase in NO or pH by phyto-S1P/S1P. The stomatal closure by phyto-S1P/S1P was mediated by phospholipase D and phosphatidic acid (PA). When present, PA elevated the levels of pH, but not NO of guard cells. Our results demonstrate that stomatal closure induced by phyto-S1P and S1P depends on rise in pH as well as NO of guard cells. A scheme of signaling events initiated by phyto-S1P/S1P, and converging to cause stomatal closure, is proposed.

  8. Transcatheter closure of patent foramen ovale for secondary prevention of ischemic stroke: Quantitative synthesis of pooled randomized trial data.

    PubMed

    Hakeem, Abdul; Cilingiroglu, Mehmet; Katramados, Angelos; Boudoulas, Konstantinos Dean; Iliescu, Cezar; Gundogdu, Betul; Marmagkiolis, Konstantinos

    2018-01-14

    To evaluate the safety and efficacy of percutaneous device closure of patent foramen ovale (PFO) for secondary prevention of ischemic stroke BACKGROUND: Stroke remains the leading cause of serious long-term disability in the United States. The effectiveness of a percutaneous PFO closure in the prevention of recurrent cryptogenic strokes has not been established. We performed a literature search using PubMed, EMBASE, Cochrane Central Register of Controlled Trials, Google Scholar, and Internet-based sources from January 2003 to September 2017. Randomized controlled trails (RCTs) comparing percutaneous PFO closure to medical therapy alone. Five RCTs (CLOSURE I, PC Trial, REDUCE, RESPECT, and CLOSE) with 1,829 patients in the device group and 1,611 patients in the medical group met inclusion criteria. The cumulative incidence of recurrent stroke was 2.02% in the PFO closure arm and 4.4% in the medical therapy group (RR 0.42, 95%CI 0.20, 0.91; P = 0.03). There was no difference in the incidence of death [0.7% vs. 0.9%; RR 0.76 (95% CI 0.35, 1.64), P = 0.49] or adverse events during the follow-up period [24.6% vs. 23.7% (RR 1.03; 95% CI 0.91, 1.16), P = 0.65] between the closure and medical therapy groups. Incidence of atrial fibrillation was significantly higher in closure group compared to medical therapy [4% vs. 0.6% (RR 4.73; 95% CI 2.09, 10.70), P = 0.0002]. The comparative effectiveness of PFO closure (compared to medical therapy) was significantly more pronounced in those younger than 45 years, males, larger shunts and disc design platforms (P < 0.05). Based on the results of this analysis of randomized trial data, percutaneous PFO closure appears to be a safe and effective therapeutic option for the secondary prevention of ischemic stroke in patients with PFO and cryptogenic stroke. © 2018 Wiley Periodicals, Inc.

  9. The economics of potential reduction of the rural road system in Kansas.

    DOT National Transportation Integrated Search

    2011-11-01

    Benefitcost analysis was used to examine the question of road closure in the three counties. The cost of road : closure is the additional travel cost of rural residents due to more circuitous routing to their destinations. The benefit is : the avo...

  10. Transportation impacts of the Chicago River closure to prevent an asian carp infestation.

    DOT National Transportation Integrated Search

    2012-07-01

    This project develops a simple linear programming model of the Upper Midwest regions rail transportation network to test : whether a closure of the Chicago River to freight traffic would impact the capacity constraint of the rail system. The result :...

  11. Boundary Closures for Fourth-order Energy Stable Weighted Essentially Non-Oscillatory Finite Difference Schemes

    NASA Technical Reports Server (NTRS)

    Fisher, Travis C.; Carpenter, Mark H.; Yamaleev, Nail K.; Frankel, Steven H.

    2009-01-01

    A general strategy exists for constructing Energy Stable Weighted Essentially Non Oscillatory (ESWENO) finite difference schemes up to eighth-order on periodic domains. These ESWENO schemes satisfy an energy norm stability proof for both continuous and discontinuous solutions of systems of linear hyperbolic equations. Herein, boundary closures are developed for the fourth-order ESWENO scheme that maintain wherever possible the WENO stencil biasing properties, while satisfying the summation-by-parts (SBP) operator convention, thereby ensuring stability in an L2 norm. Second-order, and third-order boundary closures are developed that achieve stability in diagonal and block norms, respectively. The global accuracy for the second-order closures is three, and for the third-order closures is four. A novel set of non-uniform flux interpolation points is necessary near the boundaries to simultaneously achieve 1) accuracy, 2) the SBP convention, and 3) WENO stencil biasing mechanics.

  12. Closure of logging wounds after 10 years

    Treesearch

    H. Clay Smith; Gary W. Miller; Thomas M. Schuler

    1994-01-01

    Closure of logging wounds on 96 sample trees was evaluated after 2, 5, and 10 years for Appalachian hardwood trees in north-central West Virginia. For yellow-poplar, northern red oak, black cherry, and white oak, many small wounds, 1 to 50 square inches in size, closed between 5 and 10 years after logging. For larger wounds, 50 to 200 square inches, it appears that...

  13. Enterocutaneous Fistula: Different Surgical Intervention Techniques for Closure along with Comparative Evaluation of Aluminum Paint, Karaya Gum (Hollister) and Gum Acacia for Peristomal Skin Care

    PubMed Central

    Namrata; Ahmad, Shabi

    2015-01-01

    Introduction Gastrointestinal fistulas are serious complications and are associated with high morbidity and mortality rates. In majority of the patients, fistulas are treatable. However, the treatment is very complex and often multiple therapies are required. These highly beneficial treatment options which could shorten fistula closure time also result in considerable hospital cost savings. Aim This study was planned to study aetiology, clinical presentation, morbidity and mortality of enterocutaneous fistula and to evaluate the different surgical intervention techniques for closure of enterocutaneous fistula along with a comparative evaluation of different techniques for management of peristomal skin with special emphasis on aluminum paint, Karaya gum (Hollister) and Gum Acacia. Materials and Methods This prospective observational study was conducted in the Department of Surgery, M.L.N. Medical College, Allahabad and its associated hospital (S.R.N. Hospital, Allahabad) for a period of five years. Results Majority of enterocutaneous fistula were of small bowel and medium output fistulas (500-1000 ml/24hours). Most of the patients were treated with conservative treatment as compared to surgical intervention. Large bowel fistula has maximum spontaneous closure rate compare to small bowel and duodenum. Number of orifice whether single or multiple does not appear to play statistically significant role in spontaneous closure of fistula. Serum Albumin is a significantly important predictor of spontaneous fistula closure and mortality. Surgical management appeared to be the treatment of choice in distal bowel fistula. The application of karaya gum (Hollister kit), Gum Acacia and Aluminum Paint gave similar outcome. Conclusion Postoperative fistulas are the most common aetiology of enterocutaneous fistula and various factors do play role in management. Peristomal skin care done with Karaya Gum, Gum Acacia and Aluminum Paint has almost equal efficiency in management of skin excoriation. However, role of Gum Acacia was found to be good with inflamed, excoriated and ulcerative skin in comparison to Aluminum Paint and as efficacious as Karaya Gum but at much lower cost. PMID:26816943

  14. 3013 DE INNER CONTAINER CLOSURE WELD CORROSION EVALUATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mickalonis, J.

    Destructive evaluation (DE) of 3013 containers is one part of the U. S. Department of Energy Integrated Surveillance Program. During standard DE of 3013 containers, visual examinations for pitting and stress corrosion cracking (SCC) are performed on the accessible surfaces of the outer, inner, and convenience containers, which make up the 3013 container. As a result of 3013 DE additional analysis, the area near the inner container closure weld has been identified as being a region of increased corrosion susceptibility, which may provide a pathway for corrosive gases to the outer container. This area has a higher residual stress, anmore » altered microstructure, and less corrosion resistant weld oxides as a result of the welding process as well as a lower temperature than other areas of the container, which may increase the absorption of moisture on the surface. The deposition of moisture in this stressed region could lead to pitting and stress corrosion cracking. During FY2013, the inner container closure weld area was more closely evaluated on several archived samples from DE containers. These containers included FY09 DE2, FY12 DE4, FY12 DE6 and FY12 DE7 and the Hanford High Moisture Container. The additional examinations included visual observations with a stereomicroscope, scanning electron microscopy along with energy dispersive spectroscopy for chemical analysis, and serial metallography of the sidewall and lid that are part of the inner container closure weld region. Pitting was observed in all the samples taken from the closure weld regions of the examined inner containers. This pitting was generally less 20 μm with most less than 5m. These pits were similar in depth to those observed in the vapor exposed surfaces of teardrops in the shelf life corrosion testing. Cracking was not observed on either the vapor-exposed surfaces of the teardrop coupons or the inner container closure weld region. Further testing is necessary to determine if the conditions in the welded inner container could support SCC during the 50 year life time for the 3013 container.« less

  15. The Superfund Innovative Technology Evaluation Program SUMMARY AND CLOSURE REPORT

    EPA Science Inventory

    The Superfund Innovative Technology Evaluation (SITE) Program promoted the development, commercialization, and implementation of innovative hazardous waste treatment technologies for 20 years. SITE offered a mechanism for conducting joint technology demonstration and evaluation ...

  16. Hamiltonian closures in fluid models for plasmas

    NASA Astrophysics Data System (ADS)

    Tassi, Emanuele

    2017-11-01

    This article reviews recent activity on the Hamiltonian formulation of fluid models for plasmas in the non-dissipative limit, with emphasis on the relations between the fluid closures adopted for the different models and the Hamiltonian structures. The review focuses on results obtained during the last decade, but a few classical results are also described, in order to illustrate connections with the most recent developments. With the hope of making the review accessible not only to specialists in the field, an introduction to the mathematical tools applied in the Hamiltonian formalism for continuum models is provided. Subsequently, we review the Hamiltonian formulation of models based on the magnetohydrodynamics description, including those based on the adiabatic and double adiabatic closure. It is shown how Dirac's theory of constrained Hamiltonian systems can be applied to impose the incompressibility closure on a magnetohydrodynamic model and how an extended version of barotropic magnetohydrodynamics, accounting for two-fluid effects, is amenable to a Hamiltonian formulation. Hamiltonian reduced fluid models, valid in the presence of a strong magnetic field, are also reviewed. In particular, reduced magnetohydrodynamics and models assuming cold ions and different closures for the electron fluid are discussed. Hamiltonian models relaxing the cold-ion assumption are then introduced. These include models where finite Larmor radius effects are added by means of the gyromap technique, and gyrofluid models. Numerical simulations of Hamiltonian reduced fluid models investigating the phenomenon of magnetic reconnection are illustrated. The last part of the review concerns recent results based on the derivation of closures preserving a Hamiltonian structure, based on the Hamiltonian structure of parent kinetic models. Identification of such closures for fluid models derived from kinetic systems based on the Vlasov and drift-kinetic equations are presented, and connections with previously discussed fluid models are pointed out.

  17. Efficacy of stapler pharyngeal closure after total laryngectomy: A systematic review.

    PubMed

    Aires, Felipe T; Dedivitis, Rogério A; Castro, Mario Augusto F; Bernardo, Wanderley Marques; Cernea, Claudio Roberto; Brandão, Lenine Garcia

    2014-05-01

    Some primary studies compare manual and mechanical pharyngeal closures after total laryngectomy. The purpose of this study was to evaluate the advantages of the mechanical suture in pharyngeal closure. The literature survey included research in MEDLINE, EMBASE, and LILACS. The intervention analyzed was stapler-assisted pharyngeal closure, whereas the control group was manual suture pharyngeal closure. The survey resulted in 319 studies. However, 4 studies were selected (417 patients). In the group of patients in whom the stapler was used, the incidence of pharyngocutaneous fistula was 8.7%, whereas in the other, it was 22.9%, with an absolute risk reduction of 15% (95% confidence interval [CI], 0.02-0.28; p = .02; I(2) = 66%). Regarding the surgical time, the average difference was 80 minutes in favor of the stapler group (95% CI, 23.16-136.58 minutes; p < .006). The difference for starting oral feeding was 8 days in favor of the mechanical suture (95% CI, 4.01-11.73 days; p < .001). Patients who underwent mechanical suture had a shorter hospitalization period. Copyright © 2013 Wiley Periodicals, Inc.

  18. Periodic direct current does not promote wound closure in an in vitro dynamic model of cell migration.

    PubMed

    Godbout, Charles; Frenette, Jérôme

    2006-01-01

    A prevailing paradigm is that electrical fields can promote cell migration and tissue healing. To further validate this paradigm, we tested the hypothesis that periodic direct current (DC) can enhance wound closure using an in vitro dynamic model of cell migration. Layers of primary fibroblasts were wounded and treated with DC under various voltages. Repair area, cell velocity, and directionality as well as lamellipodium area were evaluated at different times. Direct current had no beneficial effect on cell migration. Moreover, prolonged stimulation under the highest voltage led to significant reduction in wound closure and cell velocity. The reduction of membrane protusions in stimulated cells may be associated with the deleterious effect of DC. Contrary to the authors' expectations, they found that periodic DC did not promote wound closure, a finding that emphasizes the need to clarify the complex effects of electrical fields on migrating cells.

  19. Humid site stabilization and closure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cutshall, N.H.

    1981-01-01

    The purpose of the work described here is to identify and evaluate the importance of factors that are expected to dictate the nature of site stabilization and closure requirements. Subsequent efforts will plan for implementation of such requirements. Two principal areas of site stabilization and closure effort will be pursued initially - geological management and vegetation management. The geological effort will focus on chemical weathering and surficial erosion. Such catastrophic geologic events as landslides, flooding, earthquakes, volcanos, etc. are already considered in site selection and operation and these factors will not be emphasized initially. Vegetation management will be designed tomore » control erosion, to minimize nuclide mobilization by roots and to be compatible with natural successional pressures. It is anticipated that the results of this work will be important both to site selection and operation as well as the actual stabilization and closure procedure.« less

  20. Stapler Esophageal Closure During Total Laryngectomy.

    PubMed

    Ismi, Onur; Unal, Murat; Vayisoglu, Yusuf; Yesilova, Mesut; Helvaci, Ilter; Gorur, Kemal; Ozcan, Cengiz

    2017-01-01

    Mechanical esophageal closure with stapler during total laryngectomy has been used by various authors to decrease the surgical time and pharyngocutaneous fistula (PCF) rates. In a few of the studies, surgical site infection (SSI) rates are mentioned and none of the studies emphasize the effect of decreased surgical time on postoperative cardiovascular and cerebrovascular complications. In this study, the authors compared the PCF rates, SSI rates, operation times between 30 mechanical stapler and 40 manual esophageal closure during total laryngectomy for laryngeal cancer patients. National Nasocomial Infections Surveillance system (NNISS) scores were recorded and compared between groups. Total laryngectomy and total operation times were lower in the stapler group patients (P < 0.001 for total laryngectomy time, P = 0.024 for total operation time). There were lower rates of pharyngocutaneous fistula (P = 0.032), surgical site infection (P = 0.019), and NNISS scores (P = 0.009) in the stapler group. There was no statistically significant difference between groups regarding postoperative systemic complications (P = 0.451). In conclusion, stapler esophageal closure decreases operation time, PCF, SSI rates, and NNISS scores but not the systemic complication rates. Comorbid illnesses and prolonged surgical time are risk factors for postoperative systemic complications in total laryngectomy patients, but patients with additional illnesses must not encourage the surgeon to use stapler for decreasing postoperative systemic complications.

  1. Magnetic resonance imaging study of eye congenital birth defects in mouse model

    PubMed Central

    Tucker, Zachary; Mongan, Maureen; Meng, Qinghang; Xia, Ying

    2017-01-01

    Purpose Embryonic eyelid closure is a well-documented morphogenetic episode in mammalian eye development. Detection of eyelid closure defect in humans is a major challenge because eyelid closure and reopen occur entirely in utero. As a consequence, congenital eye defects that are associated with failure of embryonic eyelid closure remain unknown. To fill the gap, we developed a mouse model of defective eyelid closure. This preliminary work demonstrates that the magnetic resonance imaging (MRI) approach can be used for the detection of extraocular muscle abnormalities in the mouse model. Methods Mice with either normal (Map3k1+/−) or defective (Map3k1−/−) embryonic eyelid closure were used in this study. Images of the extraocular muscles were obtained with a 9.4 T high resolution microimaging MRI system. The extraocular muscles were identified, segmented, and measured in each imaging slice using an in-house program. Results In agreement with histological findings, the imaging data show that mice with defective embryonic eyelid closure develop less extraocular muscle than normal mice. In addition, the size of the eyeballs was noticeably reduced in mice with defective embryonic eyelid closure. Conclusions We demonstrated that MRI can potentially be used for the study of extraocular muscle in the mouse model of the eye open-at-birth defect, despite the lack of specificity of muscle group provided by the current imaging resolution. PMID:28848319

  2. 40 CFR 63.962 - Standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... shall control air emissions from the individual drain system using one or a combination of the following... closure device. (3) Junction box control requirements. Each junction box shall be equipped with controls as follows: (i) The junction box shall be equipped with a closure device (e.g., manhole cover, access...

  3. 40 CFR 63.962 - Standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... shall control air emissions from the individual drain system using one or a combination of the following... closure device. (3) Junction box control requirements. Each junction box shall be equipped with controls as follows: (i) The junction box shall be equipped with a closure device (e.g., manhole cover, access...

  4. 40 CFR 63.962 - Standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... shall control air emissions from the individual drain system using one or a combination of the following... closure device. (3) Junction box control requirements. Each junction box shall be equipped with controls as follows: (i) The junction box shall be equipped with a closure device (e.g., manhole cover, access...

  5. 40 CFR 63.962 - Standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... shall control air emissions from the individual drain system using one or a combination of the following... closure device. (3) Junction box control requirements. Each junction box shall be equipped with controls as follows: (i) The junction box shall be equipped with a closure device (e.g., manhole cover, access...

  6. 36 CFR 13.1242 - BCDA closures and restrictions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false BCDA closures and restrictions. 13.1242 Section 13.1242 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Katmai National Park and...

  7. VR closure rates for two vocational models.

    PubMed

    Fraser, Virginia V; Jones, Amanda M; Frounfelker, Rochelle; Harding, Brian; Hardin, Teresa; Bond, Gary R

    2008-01-01

    The Individual Placement and Support (IPS) model of supported employment is an evidence-based practice for individuals with psychiatric disabilities. To be financially viable, IPS programs require funding from the state-federal vocational rehabilitation (VR) system. However, some observers have questioned the compatibility of IPS and the VR system. Using a randomized controlled trial comparing IPS to a well-established vocational program called the Diversified Placement Approach (DPA), we examined rates of VR sponsorship and successful VR closures. We also describe the establishment of an active collaboration between a psychiatric rehabilitation agency and the state VR system to facilitate rapid VR sponsorship for IPS clients. Both IPS and DPA achieved a 44% rate of VR Status 26 closure when considering all clients entering the study. IPS and DPA averaged similar amount of time to achieve VR sponsorship. Time from vocational program entry to Status 26 was 51 days longer on average for IPS. Even though several IPS principles seem to run counter to VR practices, such as zero exclusion and rapid job search, we found IPS closure rates comparable to those for DPA, a vocational model that screens for readiness, provides prevocational preparation, and extensively uses agency-run businesses.

  8. RELAP-7 Closure Correlations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zou, Ling; Berry, R. A.; Martineau, R. C.

    The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The code is based on the INL’s modern scientific software development framework, MOOSE (Multi-Physics Object Oriented Simulation Environment). The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical integration methods, and physical models. The end result will be a reactor systems analysis capability that retains and improves upon RELAP5’s and TRACE’s capabilities and extends their analysis capabilities for all reactor system simulation scenarios. The RELAP-7 codemore » utilizes the well-posed 7-equation two-phase flow model for compressible two-phase flow. Closure models used in the TRACE code has been reviewed and selected to reflect the progress made during the past decades and provide a basis for the colure correlations implemented in the RELAP-7 code. This document provides a summary on the closure correlations that are currently implemented in the RELAP-7 code. The closure correlations include sub-grid models that describe interactions between the fluids and the flow channel, and interactions between the two phases.« less

  9. Simulated Leaching (Migration) Study for a Model Container-Closure System Applicable to Parenteral and Ophthalmic Drug Products.

    PubMed

    Jenke, Dennis; Egert, Thomas; Hendricker, Alan; Castner, James; Feinberg, Tom; Houston, Christopher; Hunt, Desmond G; Lynch, Michael; Nicholas, Kumudini; Norwood, Daniel L; Paskiet, Diane; Ruberto, Michael; Smith, Edward J; Holcomb, Frank; Markovic, Ingrid

    2017-01-01

    A simulating leaching (migration) study was performed on a model container-closure system relevant to parenteral and ophthalmic drug products. This container-closure system consisted of a linear low-density polyethylene bottle (primary container), a polypropylene cap and an elastomeric cap liner (closure), an adhesive label (labeling), and a foil overpouch (secondary container). The bottles were filled with simulating solvents (aqueous salt/acid mixture at pH 2.5, aqueous buffer at pH 9.5, and 1/1 v/v isopropanol/water), a label was affixed to the filled and capped bottles, the filled bottles were placed into the foil overpouch, and the filled and pouched units were stored either upright or inverted for up to 6 months at 40 °C. After storage, the leaching solutions were tested for leached substances using multiple complementary analytical techniques to address volatile, semi-volatile, and non-volatile organic and inorganic extractables as potential leachables.The leaching data generated supported several conclusions, including that (1) the extractables (leachables) profile revealed by a simulating leaching study can qualitatively be correlated with compositional information for materials of construction, (2) the chemical nature of both the extracting medium and the individual extractables (leachables) can markedly affect the resulting profile, and (3) while direct contact between a drug product and a system's material of construction may exacerbate the leaching of substances from that material by the drug product, direct contact is not a prerequisite for migration and leaching to occur. LAY ABSTRACT: The migration of container-related extractables from a model pharmaceutical container-closure system and into simulated drug product solutions was studied, focusing on circumstances relevant to parenteral and ophthalmic drug products. The model system was constructed specifically to address the migration of extractables from labels applied to the outside of the primary container. The study demonstrated that (1) the extractables that do migrate can be correlated to the composition of the materials used to construct the container-closure systems, (2) the extent of migration is affected by the chemical nature of the simulating solutions and the extractables themselves, and (3) even though labels may not be in direct contact with a contained solution, label-related extractables can accumulate as leachables in those solutions. © PDA, Inc. 2017.

  10. Assessment of circumferential angle-closure by the iris-trabecular contact index with swept-source optical coherence tomography.

    PubMed

    Baskaran, Mani; Ho, Sue-Wei; Tun, Tin A; How, Alicia C; Perera, Shamira A; Friedman, David S; Aung, Tin

    2013-11-01

    To evaluate the diagnostic performance of the iris-trabecular contact (ITC) index, a measure of the degree of angle-closure, using swept-source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan) in comparison with gonioscopy. Prospective observational study. A total of 108 normal subjects and 32 subjects with angle-closure. The SSOCT 3-dimensional angle scans, which obtain radial scans for the entire circumference of the angle, were performed under dark conditions and analyzed using customized software by a single examiner masked to the subjects' clinical details. The ITC index was calculated as a percentage of the angle that was closed on SSOCT images. First-order agreement coefficient (AC1) statistics and area under the receiver operating characteristic curve (AUC) analyses were performed for angle-closure on the basis of the ITC index in comparison with gonioscopy. Angle-closure on gonioscopy was defined as nonvisibility of posterior trabecular meshwork for at least 2 quadrants. Agreement of the ITC index with gonioscopically defined angle-closure was assessed using the AC1 statistic. Study subjects were predominantly Chinese (95.7%) and female (70.7%), with a mean age of 59.2 (standard deviation, 8.9) years. The median ITC index was 15.24% for gonioscopically open-angle eyes (n = 108) and 48.5% for closed-angle eyes (n = 32) (P = 0.0001). The agreement for angle-closure based on ITC index cutoffs (>35% and ≥50%) and gonioscopic angle-closure was 0.699 and 0.718, respectively. The AUC for angle-closure detection using the ITC index was 0.83 (95% confidence interval, 0.76-0.89), with an ITC index >35% having a sensitivity of 71.9% and specificity of 84.3%. The ITC index is a summary measure of the circumferential extent of angle-closure as imaged with SSOCT. The index had moderate agreement and good diagnostic performance for angle-closure with gonioscopy as the reference standard. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  11. Skin closure with dye-enhanced laser welding and fibrinogen.

    PubMed

    Wider, T M; Libutti, S K; Greenwald, D P; Oz, M C; Yager, J S; Treat, M R; Hugo, N E

    1991-12-01

    The topical application of wavelength-specific dye and fibrinogen has been used to enhance laser closure of vascular anastomoses. We compared the closure of skin incisions by two different dye-enhanced, fibrinogen-based laser welding systems [argon laser (power density 4.78 W/cm2) with fluorescein isothiocyanate dye (n = 32) and diode laser (power density 9.55 W/cm2) with indocyanine green dye (n = 32)] with closure by interrupted 5-0 nylon suture (n = 64) and examined tensile strength, hydroxyproline production, histology, and cosmesis. Two 3-cm full-thickness incisions were made on the shaved backs of 64 rats. One incision was closed with suture, whereas the other, after treatment with the appropriate dye, was welded with either argon- or diode-lasered fibrinogen. At postoperative days 5, 10, 15, and 28, the closure sites were harvested and sectioned for analysis. Initially, wounds closed with argon-lasered fibrinogen showed less inflammatory response, greater collagen production (34.61 +/- 0.74 mg/gm), and greater mean peak stress at rupture (64.85 lbs/in2) than those closed with suture (16.42 +/- 3.20 mg/gm, 26.68 lbs/in2) (p less than 0.05). By 15 days, both argon and diode laser closures are superior in strength and collagen production to suture closure (p less than 0.05). At 28 days, diode laser closures (1315.60 lbs/in2) are stronger than suture closures (998.09 lbs/in2), whereas both are stronger than argon laser closures (813.16 lbs/in2) (p less than 0.05). Cosmetically, argon-welded wounds consistently appeared finer and lacked cross-hatched suture scars.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Corrective Action Decision Document/Closure Report for Corrective Action Unit 219: Septic Systems and Injection Wells, Nevada Test Site, Nevada, Rev. No.: 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David Strand

    2006-05-01

    This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit (CAU) 219, Septic Systems and Injection Wells, in Areas 3, 16, and 23 of the Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 219 is comprised of the following corrective action sites (CASs): (1) 03-11-01, Steam Pipes and Asbestos Tiles; (2) 16-04-01, Septic Tanks (3); (3) 16-04-02, Distribution Box; (4) 16-04-03, Sewer Pipes; (5) 23-20-01, DNA Motor Pool Sewage and Waste System; and (6) 23-20-02, Injection Well. The purpose of this Corrective Action Decision Document/Closure Report ismore » to provide justification and documentation supporting the recommendation for closure of CAU 219 with no further corrective action beyond the application of a use restriction at CASs 16-04-01, 16-04-02, and 16-04-03. To achieve this, corrective action investigation (CAI) activities were performed from June 20 through October 12, 2005, as set forth in the CAU 219 Corrective Action Investigation Plan and Record of Technical Change No. 1. A best management practice was implemented at CASs 16-04-01, 16-04-02, and 16-04-03, and corrective action was performed at CAS 23-20-01 between January and April 2006. In addition, a use restriction will be applied to CASs 16-04-01, 16-04-02, and 16-04-03 to provide additional protection to Nevada Test Site personnel. The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: (1) Determine whether contaminants of concern (COCs) are present. (2) If COCs are present, determine their nature and extent. (3) Provide sufficient information and data to complete appropriate corrective actions. The CAU 219 dataset from the investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the quality and acceptability of the dataset for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against final action levels (FALs) established in this document. A Tier 2 evaluation was conducted, and a FAL of 185,000 micrograms per kilogram was calculated for chlordane at CASs 16-04-01, 16-04-02, and 16-04-03 based on an occasional use area exposure scenario. This evaluation of chlordane based on the Tier 2 FAL determined that no FALs were exceeded. Therefore, the DQO data needs were met, and it was determined that no corrective action (based on risk to human receptors) is necessary for the site. The following contaminants were determined to be present at concentrations exceeding their corresponding FALs: (1) The surface soil surrounding the main concrete pad at CAS 23-20-01 contained Aroclor-1254, Aroclor-1260, and chlordane above the FALs. This soil, along with the COCs, was subsequently removed at CAS 23-20-01. (2) The sludge in the concrete box of the catch basin at the large concrete pad at CAS 23-20-01 contained lead and benzo(a)pyrene above the FALs. This contamination was limited to the sludge in the concrete box of the catch basin and did not migrate to the subsurface features beneath it. The contaminated and the concrete box of the catch basin were subsequently recovered at CAS 23-20-01.« less

  13. Multifunctional activities of KSLW synthetic antimicrobial decapeptide: Implications for wound healing

    NASA Astrophysics Data System (ADS)

    Williams, Richard Leroy

    Wound healing is a complex process leading to the maintenance of skin integrity. Stress is known to increase susceptibility to bacterial infection, alter proinflammatory cytokine expression, and delay wound closure. Recently, antimicrobial peptides have generated interest due to their prokaryotic selectivity, decreased microbial resistance and multifunctional roles in wound healing, including fibroblast stimulation, keratinocyte migration and leukocyte migration. The objective of this dissertation project was to evaluate the effect of a synthetic antimicrobial decapeptide (KSLW) on bacterial clearance inflammation, and wound closure during stress-impaired healing. SKH-1 mice were randomly assigned to either control or restraint-stressed (RST) groups. Punch biopsy wounds (3.5 mm in diameter) were created bilaterally on the dorsal skin. Wounds were injected with 50 microL of empty carriers or KSLW prepared in Pluronic-F68, phospholipid micelles, or saline. Bacterial assays of harvested wounds were conducted on BHI agar. Wound closure was determined by photoplanimetry. Cytokine and growth factor mRNA expression was assessed with real-time RT-PCR. Human neutrophil migration assays and checkerboard analyses were performed using Transweli plates, and counting on hemacytometer. Oxidative burst activity was measured by spectrophotometric analysis of 2,7-dichlorofluorescein oxidation. KSLW-treatment resulted in significant reductions in bacterial load among RST mice, with no difference from control after 24h. The effect was sustained 5 days post-wounding, in RST mice treated with KSLW-F68. Temporal analysis of gene induction revealed reversals of stress-induced altered expression of growth factors, proinflammatory cytokines, and chemokines essential for favorable wound healing, at various time points. KSLW-treatment in RST mice demonstrated faster wound closure throughout the stress period. KSLW, at micromolar concentrations, demonstrated a significant effect on neutrophil migration and oxidative burst. These data suggest KSLW enhances bacterial clearance and promotes proinflammatory activity during early wound healing in stressed mice. Peptide delivery in Pluronic-F68 demonstrated increased substantivity, with faster wound closure, compared to other delivery systems. In addition to its antimicrobial activity, KSLW was shown to enhance neutrophil chemotaxis and sustain cell viability by inhibition of oxidative burst responses. Taken together, the cationic peptide may be implicated in the management of infection in different systems demonstrating impaired healing, including diabetes, age, hormone-imbalance, and bum models.

  14. Design, permitting, and construction issues associated with closure of the Panna Maria uranium tailings impoundment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strachan, C.L.; Raabe, K.L.

    1997-12-31

    In 1992, Panna Maria Uranium Operations (PMUO) initiated licensing and engineering activities for closure of the Panna Maria mill and 150-acre tailings impoundment located in southeast Texas. Closure of the tailings impoundment is permitted by license amendment through the Texas Natural Resources Conservation Commission (TNRCC), and based on closure criteria outlined in Texas regulations. The closure plan for the Panna Maria tailings impoundment was submitted for Texas regulatory agency review in April 1993, with details of the closure plan modified in 1994, 1995, and 1996. The closure plan included a multi-layered cover over the regraded tailings surface which was designedmore » for long-term isolation of tailings, reduction of radon emanation to regulated levels, and reduction of infiltration to TNRCC-accepted levels. The cover and embankment slope surfaces and surrounding areas were designed to provide acceptable erosional stability as compared to runoff velocities from the Probable Maximum Precipitation event. Cover materials were selected from on-site materials and evaluated for suitability based on permeability, radon attenuation, and soil dispersivity characteristics. Off-site materials were used when necessary. The cover over the tailings has a maximum slope of 0.5 percent, and the regraded embankment slopes outside the perimeter of the impoundment have a maximum slope of 20 percent. All reclaimed slopes are covered with topsoil and revegetated. A riprap-lined channel is to be used to convey runoff from within the perimeter of the reclaimed impoundment to the north of the impoundment.« less

  15. Streamlined Approach for Environmental Restoration Plan for Corrective Action Unit 574: Neptune, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2011-08-31

    This Streamlined Approach for Environmental Restoration (SAFER) Plan identifies the activities required for closure of Corrective Action Unit (CAU) 574, Neptune. CAU 574 is included in the Federal Facility Agreement and Consent Order (FFACO) (1996 [as amended March 2010]) and consists of the following two Corrective Action Sites (CASs) located in Area 12 of the Nevada National Security Site: (1) CAS 12-23-10, U12c.03 Crater (Neptune); (2) CAS 12-45-01, U12e.05 Crater (Blanca). This plan provides the methodology for the field activities that will be performed to gather the necessary information for closure of the two CASs. There is sufficient information andmore » process knowledge regarding the expected nature and extent of potential contaminants to recommend closure of CAU 574 using the SAFER process. Based on historical documentation, personnel interviews, site process knowledge, site visits, photographs, field screening, analytical results, the results of the data quality objective (DQO) process (Section 3.0), and an evaluation of corrective action alternatives (Appendix B), closure in place with administrative controls is the expected closure strategy for CAU 574. Additional information will be obtained by conducting a field investigation to verify and support the expected closure strategy and provide a defensible recommendation that no further corrective action is necessary. This will be presented in a Closure Report that will be prepared and submitted to the Nevada Division of Environmental Protection (NDEP) for review and approval.« less

  16. Transcatheter Closure of Patent Foramen Ovale: A Single Center Experience

    PubMed Central

    Milev, Ivan; Zafirovska, Planinka; Zimbakov, Zan; Idrizi, Shpend; Ampova-Sokolov, Vilma; Gorgieva, Emilija; Ilievska, Liljana; Tosheski, Goce; Hristov, Nikola; Georgievska-Ismail, Ljubica; Anguseva, Tanja; Mitrev, Zan

    2016-01-01

    BACKGROUND: Percutaneous transcatheter closure (PTC) of patent foramen ovale (PFO) is implicated in cryptogenic stroke, transitional ischemic attack (TIA) and treatment of a migraine. AIM: Our goal was to present our experience in the interventional treatment of PFO, as well as to evaluate the short and mid-term results in patients with closed PFO. MATERIAL AND METHODS: Transcatheter closure of PFO was performed in 52 patients (67.3% women, mean age 40.7 ± 11.7 years). Patients were interviewed for subjective grading of the intensity of headaches before and after the PFO closure. RESULTS: During 2 years of follow-up, there was no incidence of new stroke, TIA and/or syncope. Follow-up TCD performed in 35 patients showed complete PFO closure in 20 patients (57.1%). Out of 35 patients, 22 (62.9%) reported having a migraine before the procedure with an intensity of headaches at 8.1 ± 1.9 on a scale from 1 to 10. During 2 years of follow-up, symptoms of a migraine disappeared in 4 (18.2%) and the remaining 18 patients reported the significant decrease in intensity 4.8 ± 2.04 (p = 0.0001). In addition, following PFO closure the incidence of the headaches decreased significantly (p = 0.0001). CONCLUSIONS: Percutaneous transcatheter closure of PFO is a safe and effective procedure showing mid-term relief of neurological symptoms in patients as well as significant reduction of migraine symptoms. PMID:28028400

  17. Vaginal delivery after Misgav-Ladach cesarean section--is the risk of uterine rupture acceptable?

    PubMed

    Hudić, Igor; Fatusić, Zlatan; Kamerić, Lejla; Misić, Mladen; Serak, Indira; Latifagić, Anela

    2010-10-01

    To evaluate whether the single-layer closure as is a routine by the Misgav-Ladach method compared to the double-layer closure as used by the Dörfler cesarean method is associated with an increased risk of uterine rupture in the subsequent pregnancy and delivery. The analysis is retrospective and is based on medical documentation of the Clinic for Gynecology and Obstetrics, University Clinical Centre, Tuzla, Bosnia and Herzegovina. All patients with one previous cesarean section who attempted vaginal birth following cesarean section were managed from 1 January 2002 to 31 December 2008. Exclusion criteria included multiple gestation, greater than one previous cesarean section, previous incision other than low transverse, gestational age at delivery less than 37 weeks and induction of delivery. We identified 448 patients who met inclusion criteria. We found that 303 patients had a single-layer closure (Misgav-Ladach) and 145 had a double-layer closure (Dörffler) of the previous uterine incision. There were 35 cases of uterine rupture. Of those patients with previous single-layer closure, 5.28% (16/303) had a uterine rupture compared to 13.11% (19/145) in the double-layer closure group (p<0.05). We have not found that a Misgav-Ladach cesarean section method (single-layer uterine closure) might be more likely to result in uterine rupture in women who attempted a vaginal birth after a previous cesarean delivery. This cesarean section method should find its confirmation in everyday clinical practice.

  18. The effect of different environmental factors on force degradation of three common systems of orthodontic space closure.

    PubMed

    Oshagh, Morteza; Khajeh, Farzaneh; Heidari, Somayeh; Torkan, Sepideh; Fattahi, Hamid Reza

    2015-01-01

    Different environmental conditions, such as high temperature or exposure to some chemical agents, may affect the force decay of different methods of space closure during orthodontic treatment. The aim of this in vitro study was to evaluate the force decay pattern in the presence of tea as a popular drink in some parts of the world and two mouthwashes that are usually prescribed by the orthodontist once the treatment is in progress. Elastic chain (EC), nickel-titanium (Ni-Ti) closed coil spring and tie-back (TB) method were used as the means of space closure. The specimens were placed in five different media: Hot tea, hot water (65°), chlorhexidine mouthwash, fluoride mouthwash and the control group (water at 37°). The specimens were stretched 25 mm and the elastic force of three systems was measured at the beginning of the study, after 24 h, after 1 week and after 3 weeks. One-way ANOVA was used to compare the results between the groups and Duncan test was carried out to compare the sets of means in different groups (P ≤ 0.05). Tea increases the force decay in the EC and TB groups. Oral mouthwashes also resulted in more rapid force decay than the control group. EC and Ni-Ti groups were not much affected in the presence of oral mouthwashes. Regarding the immersion media, TB method showed the biggest variation in different media and Ni-Ti coil spring was least affected by the type of media.

  19. The effect of different environmental factors on force degradation of three common systems of orthodontic space closure

    PubMed Central

    Oshagh, Morteza; Khajeh, Farzaneh; Heidari, Somayeh; Torkan, Sepideh; Fattahi, Hamid Reza

    2015-01-01

    Background: Different environmental conditions, such as high temperature or exposure to some chemical agents, may affect the force decay of different methods of space closure during orthodontic treatment. The aim of this in vitro study was to evaluate the force decay pattern in the presence of tea as a popular drink in some parts of the world and two mouthwashes that are usually prescribed by the orthodontist once the treatment is in progress. Materials and Methods: Elastic chain (EC), nickel-titanium (Ni-Ti) closed coil spring and tie-back (TB) method were used as the means of space closure. The specimens were placed in five different media: Hot tea, hot water (65°), chlorhexidine mouthwash, fluoride mouthwash and the control group (water at 37°). The specimens were stretched 25 mm and the elastic force of three systems was measured at the beginning of the study, after 24 h, after 1 week and after 3 weeks. One-way ANOVA was used to compare the results between the groups and Duncan test was carried out to compare the sets of means in different groups (P ≤ 0.05). Results: Tea increases the force decay in the EC and TB groups. Oral mouthwashes also resulted in more rapid force decay than the control group. EC and Ni-Ti groups were not much affected in the presence of oral mouthwashes. Conclusion: Regarding the immersion media, TB method showed the biggest variation in different media and Ni-Ti coil spring was least affected by the type of media. PMID:25709675

  20. Supersonic Aftbody Closure Wind-Tunnel Testing, Data Analysis, and Computational Results

    NASA Technical Reports Server (NTRS)

    Allen, Jerry; Martin, Grant; Kubiatko, Paul

    1999-01-01

    This paper reports on the model, test, and results from the Langley Supersonic Aftbody Closure wind tunnel test. This project is an experimental evaluation of the 1.5% Technology Concept Aircraft (TCA) aftbody closure model (Model 23) in the Langley Unitary Plan Wind Tunnel. The baseline TCA design is the result of a multidisciplinary, multipoint optimization process and was developed using linear design and analysis methods, supplemented with Euler and Navier-Stokes numerical methods. After a thorough design review, it was decided to use an upswept blade attached to the forebody as the mounting system. Structural concerns dictated that a wingtip support system would not be feasible. Only the aftbody part of the model is metric. The metric break was chosen to be at the fuselage station where prior aft-sting supported models had been truncated. Model 23 is thus a modified version of Model 20. The wing strongback, flap parts, and nacelles from Model 20 were used, whereas new aftbodies, a common forebody, and some new tails were fabricated. In summary, significant differences in longitudinal and direction stability and control characteristics between the ABF and ABB aftbody geometries were measured. Correcting the experimental data obtained for the TCA configuration with the flared aftbody to the representative of the baseline TCA closed aftbody will result in a significant reduction in longitudinal stability, a moderate reduction in stabilizer effectiveness and directional stability, and a moderate to significant reduction in rudder effectiveness. These reductions in the stability and control effectiveness levels of the baseline TCA closed aftbody are attributed to the reduction in carry-over area.

  1. Quantitative Endoscopic Phototransducer Investigation of Normal Velopharyngeal Physiology

    ERIC Educational Resources Information Center

    Karnell, Michael P.; Moon, Jerald B.; Nakajima, Kengo; Kacmarynski, Deborah S.

    2016-01-01

    Purpose: The purpose of this research was to learn the extent to which healthy individuals vary in their ability to achieve velopharyngeal closure for speech. Method: Twenty healthy adult volunteers (10 women, 10 men) were tested using an endoscopic phototransducer system that tracks variations in velopharyngeal closure during speech production.…

  2. Decision support system for road closures in flash flood emergencies.

    DOT National Transportation Integrated Search

    2013-06-01

    Among all the natural hazards, flash flood ranks as the No. 1 weather-related killer in U.S. More : than half of the deaths in flash flood are due to drowning victims in a traffic environment. So road : closure is critical to save lives from flash fl...

  3. 36 CFR 13.1910 - KNHL and developed area closures and restrictions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false KNHL and developed area closures and restrictions. 13.1910 Section 13.1910 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Wrangell-St...

  4. 36 CFR 13.1328 - EGDA closures and restrictions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false EGDA closures and restrictions. 13.1328 Section 13.1328 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Kenai Fjords National Park Exit...

  5. 36 CFR 13.1120 - Bartlett Cove Developed Area closures and restrictions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false Bartlett Cove Developed Area closures and restrictions. 13.1120 Section 13.1120 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay...

  6. 36 CFR 13.1120 - Bartlett Cove Developed Area closures and restrictions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Bartlett Cove Developed Area closures and restrictions. 13.1120 Section 13.1120 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay...

  7. Hylomorphism and the metabolic closure conception of life.

    PubMed

    DiFrisco, James

    2014-12-01

    This paper examines three exemplary theories of living organization with respect to their common feature of defining life in terms of metabolic closure: autopoiesis, (M, R) systems, and chemoton theory. Metabolic closure is broadly understood to denote the property of organized chemical systems that each component necessary for the maintenance of the system is produced from within the system itself, except for an input of energy. It is argued that two of the theories considered--autopoiesis and (M, R) systems--participate in a hylomorphist pattern of thinking which separates the "form" of the living system from its "matter." The analysis and critique of hylomorphism found in the work of the philosopher Gilbert Simondon is then applied to these two theories, and on the basis of this critique it is argued that the chemoton model offers a superior theory of minimal life which overcomes many of the problems associated with the other two. Throughout, the relationship between hylomorphism and the understanding of living things as machines is explored. The paper concludes by considering how hylomorphism as a background ontology for theories of life fundamentally influences the way life is defined.

  8. Approximations for Quantitative Feedback Theory Designs

    NASA Technical Reports Server (NTRS)

    Henderson, D. K.; Hess, R. A.

    1997-01-01

    The computational requirements for obtaining the results summarized in the preceding section were very modest and were easily accomplished using computer-aided control system design software. Of special significance is the ability of the PDT to indicate a loop closure sequence for MIMO QFT designs that employ sequential loop closure. Although discussed as part of a 2 x 2 design, the PDT is obviously applicable to designs with a greater number of inputs and system responses.

  9. Installation Restoration General Environmental Technology Development. Task 3. Guidelines for In-Place Closure of Dry Lagoons. Volume 2. Evaluation of In-Place Closure Technologies.

    DTIC Science & Technology

    1984-01-01

    fac- turs are described as follows: (a) Basil stability -- Determination of horizontal movement in the slurry wall or the ground behind the wall...SG-l.2) M Acid mine drainage (FeSO4 pH 3) N Liqnin (in Ca++ solution) N Orqanic residues trom pesticide manutacture N Alcohol M/H asiqnificant

  10. Low-level stretching accelerates cell migration into a gap.

    PubMed

    Toume, Samer; Gefen, Amit; Weihs, Daphne

    2017-08-01

    We observed that radially stretching cell monolayers at a low level (3%) increases the rate at which they migrate to close a gap formed by in vitro injury. Wound healing has been shown to accelerate in vivo when deformations are topically applied, for example, by negative pressure wound therapy. However, the direct effect of deformations on cell migration during gap closure is still unknown. Thus, we have evaluated the effect of radially applied, sustained (static) tensile strain on the kinematics of en mass cell migration. Monolayers of murine fibroblasts were cultured on stretchable, linear-elastic substrates that were subjected to different tensile strains, using a custom-designed three-dimensionally printed stretching apparatus. Immediately following stretching, the monolayer was 'wounded' at its centre, and cell migration during gap closure was monitored and quantitatively evaluated. We observed a significant increase in normalised migration rates and a reduction of gap closure time with 3% stretching, relative to unstretched controls or 6% stretch. Interestingly, the initial gap area was linearly correlated with the maximum migration rate, especially when stretching was applied. Therefore, small deformations applied to cell monolayers during gap closure enhance en mass cell migration associated with wound healing and can be used to fine-tune treatment protocols. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  11. Guided treatment improves outcome of patients with enterocutaneous fistulas.

    PubMed

    Visschers, Ruben G J; van Gemert, Wim G; Winkens, Bjorn; Soeters, Peter B; Olde Damink, Steven W M

    2012-10-01

    The present study was designed to evaluate the effects of guided treatment of patients with an enterocutaneous fistula and to evaluate the effect of prolonged period of convalescence on outcome. All consecutive patients with an enterocutaneous fistula treated between 2006 and 2010 were included in this study. Patient information was gathered prospectively. Treatment of patients focused on sepsis control, optimization of nutritional status, wound care, establishing the anatomy of the fistula, timing of surgery, and surgical principles. Outcome included spontaneous and surgical closure, mortality, and postoperative recurrence. The relationship between period of convalescence and recurrence rate was determined by combining the present prospective cohort with a historical cohort from our group. Between 2006 and 2010, 79 patients underwent focused treatment for enterocutaneous fistula. Cox regression analysis showed that period of convalescence related significantly with recurrence of the fistula (hazard ratio 0.99; 95 % confidence interval 0.98-0.999; p = 0.04). Spontaneous closure occurred in 23 (29 %) patients after a median period of convalescence of 39 (range 7-163) days. Forty-nine patients underwent operative repair after median period of 101 (range 7-374) days and achieved closure in 47 (96 %). Overall, eight patients (10 %) died. Prolonging period of convalescence for patients with enterocutaneous fistulas improves spontaneous closure and reduces recurrence rate.

  12. Delineation of First-Order Elastic Property Closures for Hexagonal Metals Using Fast Fourier Transforms

    PubMed Central

    Landry, Nicholas W.; Knezevic, Marko

    2015-01-01

    Property closures are envelopes representing the complete set of theoretically feasible macroscopic property combinations for a given material system. In this paper, we present a computational procedure based on fast Fourier transforms (FFTs) for delineation of elastic property closures for hexagonal close packed (HCP) metals. The procedure consists of building a database of non-zero Fourier transforms for each component of the elastic stiffness tensor, calculating the Fourier transforms of orientation distribution functions (ODFs), and calculating the ODF-to-elastic property bounds in the Fourier space. In earlier studies, HCP closures were computed using the generalized spherical harmonics (GSH) representation and an assumption of orthotropic sample symmetry; here, the FFT approach allowed us to successfully calculate the closures for a range of HCP metals without invoking any sample symmetry assumption. The methodology presented here facilitates for the first time computation of property closures involving normal-shear coupling stiffness coefficients. We found that the representation of these property linkages using FFTs need more terms compared to GSH representations. However, the use of FFT representations reduces the computational time involved in producing the property closures due to the use of fast FFT algorithms. Moreover, FFT algorithms are readily available as opposed to GSH codes. PMID:28793566

  13. Rubber closures for freeze-dried products.

    PubMed

    Hopkins, G H

    1976-10-01

    Once a biological product has been developed to perform its required medical or pharmaceutical function, it is essential that a container-closure system by chosen which will preserve the efficacy of the product up to the point of administration. The general requirements applicable to proper closure function will be reviewed and the suitability of natural and synthetic elastomers to perform these functions will be discussed. The specialized application of elastomeric materials as closures for freeze-dried products presents additional requirements which are superimposed upon those previously discussed. The first of these unique considerations relates to the proper physical design which will permit the outgassing of water vapor during the sublimation step in the lyophilizing chamber. During this outgassing the design must also permit the closure to remain affixed in the neck while only partially inserted. Since these preparations are lyophilized because they are unstable in aqueous solutions, the elastomer used must constitute an effective barrier to the transmission of moisture vapor through the closure. The MVT and gas transmission properties of elastomers will be discussed. Special consideration will be given to the extremely low temperatures used in the sublimation, stoppering, and storage before use of lyophilized products. The phenomenon of glass transition points with different elastomers will be explained as its relation to satisfactory performance of the closure function at low temperatures.

  14. Analysis of an algae-based CELSS. II - Options and weight analysis

    NASA Technical Reports Server (NTRS)

    Holtzapple, Mark T.; Little, Frank E.; Moses, William M.; Patterson, C. O.

    1989-01-01

    Life support components are evaluated for application to an idealized closed life support system which includes an algal reactor for food production. Weight-based trade studies are reported as 'break-even' time for replacing food stores with a regenerative bioreactor. It is concluded that closure of the life support gases (oxygen recovery) depends on the carbon dioxide reduction chemistry and that an algae-based food production can provide an attractive alternative to re-supply for longer duration missions.

  15. Analysis of an algae-based CELSS. Part 2: options and weight analysis

    NASA Technical Reports Server (NTRS)

    Holtzapple, M. T.; Little, F. E.; Moses, W. M.; Patterson, C. O.

    1989-01-01

    Life support components are evaluated for application to an idealized closed life support system which includes an algal reactor for food production. Weight-based trade studies are reported as "break-even" time for replacing food stores with a regenerative bioreactor. It is concluded that closure of the life support gases (oxygen recovery) depends on the carbon dioxide reduction chemistry and that an algae-based food production can provide an attractive alternative to re-supply for longer duration missions.

  16. Department of Clinical Investigation, Annual Research Progress Report, Fiscal Year 2007 (Madigan Army Medical Center)

    DTIC Science & Technology

    2007-09-30

    Midyer Clinical Mtg, Anaheim, CA, December 2006. Hudak ME. Consequences of Triple Therapy: Evaluation of Bleeding and Embolic Events in a Cohort of...6.5 mm cancellous screws in acute Jones fractures . Foot Ankle Int, 27(10): p. 821-5, 2006. Woebkenberg BJ, Devine JG, Rush R, Starnes B, Stinger H...Closure System Versus Best Medical Therapy in Patients with a Stroke and/or Transient Ischemic Attack Due to a Presumed Paradoxical Embolism Through

  17. Corrective Action Decision Document/Closure Report for Corrective Action Unit 371: Johnnie Boy Crater and Pin Stripe Nevada Test Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patrick Matthews

    This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit 371, Johnnie Boy Crater and Pin Stripe, located within Areas 11 and 18 at the Nevada Test Site, Nevada, in accordance with the Federal Facility Agreement and Consent Order (FFACO). Corrective Action Unit (CAU) 371 comprises two corrective action sites (CASs): • 11-23-05, Pin Stripe Contamination Area • 18-45-01, U-18j-2 Crater (Johnnie Boy) The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation that no further corrective action is needed for CAU 371 based on the implementation of correctivemore » actions. The corrective action of closure in place with administrative controls was implemented at both CASs. Corrective action investigation (CAI) activities were performed from January 8, 2009, through February 16, 2010, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 371: Johnnie Boy Crater and Pin Stripe. The approach for the CAI was divided into two facets: investigation of the primary release of radionuclides and investigation of other releases (migration in washes and chemical releases). The purpose of the CAI was to fulfill data needs as defined during the data quality objective (DQO) process. The CAU 371 dataset of investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the dataset is acceptable for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against final action levels (FALs) established in this document. Radiological doses exceeding the FAL of 25 millirem per year were not found to be present in the surface soil. However, it was assumed that radionuclides are present in subsurface media within the Johnnie Boy crater and the fissure at Pin Stripe. Due to the assumption of radiological dose exceeding the FAL, corrective actions were undertaken that consist of implementing a use restriction and posting warning signs at each site. These use restrictions were recorded in the FFACO database; the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Facility Information Management System; and the NNSA/NSO CAU/CAS files. Therefore, NNSA/NSO provides the following recommendations: • No further corrective actions are necessary for CAU 371. • A Notice of Completion to NNSA/NSO is requested from the Nevada Division of Environmental Protection for closure of CAU 371. • Corrective Action Unit 371 should be moved from Appendix III to Appendix IV of the FFACO.« less

  18. Customization of the voice prosthesis to prevent leakage from the enlarged tracheoesophageal puncture: results of a prospective trial.

    PubMed

    Lewin, Jan S; Hutcheson, Katherine A; Barringer, Denise A; Croegaert, Lindsay E; Lisec, Asher; Chambers, Mark S

    2012-08-01

    Customization of the tracheoesophageal (TE) voice prosthesis (VP) is often preferred over surgical closure to prevent aspiration around the VP in laryngectomized patients with an enlarged tracheoesophageal puncture (TEP), but it has not been thoroughly evaluated. Single-institution prospective trial. A prospective trial was conducted to evaluate the effectiveness of a customized VP with the addition of an enlarged tracheal and/or esophageal collar in patients with leakage around an enlarged TEP. Absence of leakage around the VP after placement defined immediate effectiveness. Long-term success was defined by the prevention of adverse events related to leakage during the study period. Events that defined failure included: permanent gastrostomy dependence, aspiration pneumonia, and/or surgical TEP closure. Twenty-one patients with enlarged TEP were enrolled (2003-2006). Insertion of a customized VP was unsuccessful in one patient; 145 customizations were performed in the remaining 20 patients (median, 3.5 customizations) during the trial period. Of the customizations, 77% (112/145) prevented leakage immediately after VP insertion. The most common adverse event was dislodgement of the prosthesis (11%) or the collar alone (7%) in 18% (26/145) of customized VP placements. Six patients who died of disease were not evaluable for long-term outcomes. Long-term success was achieved in 80% (12/15) of evaluable patients who avoided permanent gastrostomy, aspiration pneumonia, and surgical TEP closure. Prosthetic customization offers an effective method to prevent leakage around the VP in many patients with an enlarged TEP, thereby preserving TE voice while avoiding surgical closure in this high-risk population. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  19. Customization of the Voice Prosthesis to Prevent Leakage from the Enlarged Tracheoesophageal Puncture: Results of a Prospective Trial

    PubMed Central

    Lewin, Jan S.; Hutcheson, Katherine A.; Barringer, Denise A.; Croegaert, Lindsay E.; Lisec, Asher; Chambers, Mark S.

    2014-01-01

    Background Customization of the tracheoesophageal (TE) voice prosthesis (VP) is often preferred over surgical closure to prevent aspiration around the VP in laryngectomized patients with an enlarged tracheoesophageal puncture (TEP), but has not been thoroughly evaluated. Study Design Single-institution prospective trial. Methods A prospective trial was conducted to evaluate the effectiveness of a customized VP with the addition of an enlarged tracheal and/or esophageal collar in patients with leakage around an enlarged TEP. Absence of leakage around the VP after placement defined immediate effectiveness. Long-term success was defined by the prevention of adverse events related to leakage during the study period. Events that defined failure included: permanent gastrostomy dependence, aspiration pneumonia, and/or surgical TEP closure. Results Twenty-one patients with enlarged TEP were enrolled (2003-2006). Insertion of a customized VP was unsuccessful in 1 patient; 145 customizations were performed in the remaining 20 patients (median: 3.5 customizations) during the trial period. Seventy-seven percent (112/145) of customizations prevented leakage immediately after VP insertion. The most common adverse event was dislodgement of the prosthesis (11%) or the collar alone (7%) in 18% (26/145) of customized VP placements. Six patients who died of disease were not evaluable for long-term outcomes. Long-term success was achieved in 80% (12/ 15) of evaluable patients who avoided permanent gastrostomy, aspiration pneumonia, and surgical TEP closure. Conclusions Prosthetic customization offers an effective method to prevent leakage around the VP in many patients with an enlarged TEP, thereby preserving TE voice while avoiding surgical closure in this high risk population. PMID:22753122

  20. Automated analysis of angle closure from anterior chamber angle images.

    PubMed

    Baskaran, Mani; Cheng, Jun; Perera, Shamira A; Tun, Tin A; Liu, Jiang; Aung, Tin

    2014-10-21

    To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by κ statistic and comparison of area under receiver operating characteristic curves (AUC). One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (κ = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (κ = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  1. Post-Closure Monitoring Report for Corrective Action Unit 339: Area 12 Fleet Operations Steam Cleaning Effluent Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    K. B. Campbell

    2002-09-01

    The Area 12 Fleet Operations Steam Cleaning Effluent site is located in the southeastern portion of the Area 12 Camp at the Nevada Test Site. This site is identified in the Federal Facility Agreement and Consent Order (1996) as Corrective Action Site (CAS) 12-19-01 and is the only CAS assigned to Corrective Action Unit (CAU) 339. Post-closure sampling and inspection of the site were completed on March 27, 2002. Post-closure monitoring activities were scheduled biennially (every two years) in the Post-Closure Monitoring Plan provided in the Closure Report for CAU 339: Area 12 Fleet Operations Steam Cleaning Effluent, Nevada Testmore » Site (U.S. Department of Energy, Nevada Operations Office [DOEN], 1997). A baseline for the site was established by sampling in 1997. Based on the recommendations from the 1999 post-closure monitoring report (DOE/NV, 1999), samples were collected in 2000, earlier than originally proposed, because the 1999 sample results did not provide the expected decrease in total petroleum hydrocarbon (TPH) concentrations at the site. Sampling results from 2000 (DOE/NV, 2000) and 2001 (DOE/NV, 2001) revealed favorable conditions for natural degradation at the CAU 339 site, but because of differing sample methods and heterogeneity of the soil, data results from 2000 and later were not directly correlated with previous results. Post-closure monitoring activities for 2002 consisted of the following: (1) Soil sample collection from three undisturbed plots (Plots A, B, and C, Figure 2). (2) Sample analysis for TPH as oil and bio-characterization parameters (Comparative Enumeration Assay [CEA] and Standard Nutrient Panel [SNP]). (3) Site inspection to evaluate the condition of the fencing and signs. (4) Preparation and submittal of the Post-Closure Monitoring Report.« less

  2. Association of aortic stiffness to brain natriuretic peptide in children before and after device closure of patent ductus arteriosus

    PubMed Central

    Mahfouz, Ragab A.; Alzaiat, Ahmad; Gad, Marwa

    2014-01-01

    Objectives We evaluated the influence of device closure for patent ductus arteriosus (PDA) on the aortic stiffness index (ASI) and brain natriuretic peptide (BNP) and their association with cardiac function. Patients and methods ASI and echocardiography assessment before and after treatment (16 ± 9 months) in 48 children with PDA (mean age 10 ± 4.5) and 52 control children (mean age 9.7 ± 4.6). BNP level was measured pre-closure for all children, and was measured six months after closure only for children with PDA. Results ASI was higher in PDA patients than in controls (P < 0.001). ASI correlated with age (P < 0.05), LVEF% (P < 0.01), E/E′ (<0.03), pulmonary artery pressure (P < 0.001), and BNP (P < 0.001). ASI and BNP significantly decreased after closure (P < 0.001). ASI and BNP were independent predictors for post-closure systolic dysfunction (P < 0.001and <0.005, respectively). Receiver operating curve (ROC) analysis showed that ASI ⩾ 13.5, BNP level ⩾75 pg/ml and basal mean pulmonary artery pressure (PAP) ⩾ 23 were powerful predictors for post-closure systolic function. Conclusion ASI is significantly associated with BNP and basal PAP in children with PDA. After device closure, aortic distensibility improved significantly and was associated with significant improvement in both systolic and diastolic functions. ASI can be used for monitoring the course of patients with PDA, and may give opportunities for early intervention. PMID:25544819

  3. Transcatheter closure of large patent ductus arteriosus with severe pulmonary arterial hypertension in adults: immediate and two-year follow-up results.

    PubMed

    Zhang, Cao-Jin; Huang, Yi-Gao; Huang, Xin-Sheng; Huang, Tao; Huang, Wen-Hui; Xia, Chun-Li; Mo, Yu-Jing

    2012-11-01

    Transcatheter closure of patent ductus arteriosus (PDA) is a well established procedure and an accepted treatment modality for small to moderate-sized PDA. This study aimed to evaluate the immediate and follow-up results of transcatheter closure of large PDAs with severe pulmonary arterial hypertension (PAH) in adults. After a complete hemodynamic evaluation differentiating from the reversibility of severe PAH, transcatheter closure of PDA was performed. Patients were followed up clinically and echocardiographically at 24 hours, 1 month, 3 months, 6 months, 12 months and 24 months after occlusion. Twenty-nine patients had successful occlusion, pulmonary artery pressure (PAP), left ventricular ejection fraction (LVEF) and fractional shortening (FS) significantly decreased immediately after occlusion ((106 ± 25) mmHg vs. (50 ± 14) mmHg, P < 0.01; (63.7 ± 7.2)% vs. (51.4 ± 10.1)%, P < 0.01 and (36.9 ± 8.2)% vs. (28.9 ± 8.6)%, P < 0.05, respectively). At 1 month after PDA closure, the signs and symptoms improved markedly in all 29 patients, and PDAs were completely closed and remained closed during the follow-up. Eighteen patients having different degrees of dyspnea were treated with angiotensin converting enzyme inhibitor (ACEI) and/or digoxin after occlusion. Nine patients whose pulmonary vascular resistence (PVR) > 6 Wood units accepted targeted PAH therapy. After 1 to 3 months of peroral drug therapy, their exercise tolerance improved from New York Heart Association (NYHA) class III-IV to NYHA class I. During follow-up, no latent arrhythmias were found, the left atrial diameter (LAD), left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), left ventricular mass index (LVMI) and pulmonary artery systolic pressure (PASP) decreased significantly (P < 0.05), and FS and LVEF recovered compared to the immediate postclosure state. However, FS and LVEF remained low compared to the preclosure state. Transcatheter closure of large PDA with severe PAH is feasible, effective, and safe in adults. Significant left ventricular systolic changes may occur after closure of large PDA, and left ventricular function usually recovers within a few months.

  4. Corrective Action Management Unit Report of Post-Closure Care Activities Calendar Year 2017.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ziock, Robert; Little, Bonnie Colleen

    The Corrective Action Management Unit (CAMU) at Sandia National Laboratories, New Mexico (SNL/NM) consists of a containment cell and ancillary systems that underwent regulatory closure in 2003 in accordance with the Closure Plan in Appendix D of the Class 3 Permit Modification (SNL/NM September 1997). The containment cell was closed with wastes in place. On January 27, 2015, the New Mexico Environment Department (NMED) issued the Hazardous Waste Facility Operating Permit (Permit) for Sandia National Laboratories (NMED January 2015). The Permit became effective February 26, 2015. The CAMU is undergoing post-closure care in accordance with the Permit, as revised andmore » updated. This CAMU Report of Post-Closure Care Activities documents all activities and results for Calendar Year (CY) 2017 as required by the Permit. The CAMU containment cell consists of engineered barriers including a cover system, a bottom liner with a leachate collection and removal system (LCRS), and a vadose zone monitoring system (VZMS). The VZMS provides information on soil conditions under the cell for early leak detection. The VZMS consists of three monitoring subsystems, which include the primary subliner (PSL), a vertical sensor array (VSA), and the Chemical Waste Landfill (CWL) sanitary sewer (CSS) line. The PSL, VSA, and CSS monitoring subsystems are monitored quarterly for soil moisture concentration, the VSA is monitored quarterly for soil temperature, and the VSA and CSS monitoring subsystems are monitored annually for volatile organic compound (VOC) concentrations in the soil vapor at various depths. Baseline data for the soil moisture, soil temperature, and soil vapor were established between October 2003 and September 2004.« less

  5. Line drawing extraction from gray level images by feature integration

    NASA Astrophysics Data System (ADS)

    Yoo, Hoi J.; Crevier, Daniel; Lepage, Richard; Myler, Harley R.

    1994-10-01

    We describe procedures that extract line drawings from digitized gray level images, without use of domain knowledge, by modeling preattentive and perceptual organization functions of the human visual system. First, edge points are identified by standard low-level processing, based on the Canny edge operator. Edge points are then linked into single-pixel thick straight- line segments and circular arcs: this operation serves to both filter out isolated and highly irregular segments, and to lump the remaining points into a smaller number of structures for manipulation by later stages of processing. The next stages consist in linking the segments into a set of closed boundaries, which is the system's definition of a line drawing. According to the principles of Gestalt psychology, closure allows us to organize the world by filling in the gaps in a visual stimulation so as to perceive whole objects instead of disjoint parts. To achieve such closure, the system selects particular features or combinations of features by methods akin to those of preattentive processing in humans: features include gaps, pairs of straight or curved parallel lines, L- and T-junctions, pairs of symmetrical lines, and the orientation and length of single lines. These preattentive features are grouped into higher-level structures according to the principles of proximity, similarity, closure, symmetry, and feature conjunction. Achieving closure may require supplying missing segments linking contour concavities. Choices are made between competing structures on the basis of their overall compliance with the principles of closure and symmetry. Results include clean line drawings of curvilinear manufactured objects. The procedures described are part of a system called VITREO (viewpoint-independent 3-D recognition and extraction of objects).

  6. Influence of phase connectivity on the relationship among capillary pressure, fluid saturation, and interfacial area in two-fluid-phase porous medium systems

    DOE PAGES

    McClure, James E.; Berrill, Mark A.; Gray, William G.; ...

    2016-09-02

    Here, multiphase flow in porous medium systems is typically modeled using continuum mechanical representations at the macroscale in terms of averaged quantities. These models require closure relations to produce solvable forms. One of these required closure relations is an expression relating fluid pressures, fluid saturations, and, in some cases, the interfacial area between the fluid phases, and the Euler characteristic. An unresolved question is whether the inclusion of these additional morphological and topological measures can lead to a non-hysteretic closure relation compared to the hysteretic forms that are used in traditional models, which typically do not include interfacial areas, ormore » the Euler characteristic. We develop a lattice-Boltzmann (LB) simulation approach to investigate the equilibrium states of a two-fluid-phase porous medium system, which include disconnected now- wetting phase features. The proposed approach is applied to a synthetic medium consisting of 1,964 spheres arranged in a random, non-overlapping, close-packed manner, yielding a total of 42,908 different equilibrium points. This information is evaluated using a generalized additive modeling approach to determine if a unique function from this family exists, which can explain the data. The variance of various model estimates is computed, and we conclude that, except for the limiting behavior close to a single fluid regime, capillary pressure can be expressed as a deterministic and non-hysteretic function of fluid saturation, interfacial area between the fluid phases, and the Euler characteristic. This work is unique in the methods employed, the size of the data set, the resolution in space and time, the true equilibrium nature of the data, the parameterizations investigated, and the broad set of functions examined. The conclusion of essentially non-hysteretic behavior provides support for an evolving class of two-fluid-phase flow in porous medium systems models.« less

  7. Influence of phase connectivity on the relationship among capillary pressure, fluid saturation, and interfacial area in two-fluid-phase porous medium systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McClure, James E.; Berrill, Mark A.; Gray, William G.

    Here, multiphase flow in porous medium systems is typically modeled using continuum mechanical representations at the macroscale in terms of averaged quantities. These models require closure relations to produce solvable forms. One of these required closure relations is an expression relating fluid pressures, fluid saturations, and, in some cases, the interfacial area between the fluid phases, and the Euler characteristic. An unresolved question is whether the inclusion of these additional morphological and topological measures can lead to a non-hysteretic closure relation compared to the hysteretic forms that are used in traditional models, which typically do not include interfacial areas, ormore » the Euler characteristic. We develop a lattice-Boltzmann (LB) simulation approach to investigate the equilibrium states of a two-fluid-phase porous medium system, which include disconnected now- wetting phase features. The proposed approach is applied to a synthetic medium consisting of 1,964 spheres arranged in a random, non-overlapping, close-packed manner, yielding a total of 42,908 different equilibrium points. This information is evaluated using a generalized additive modeling approach to determine if a unique function from this family exists, which can explain the data. The variance of various model estimates is computed, and we conclude that, except for the limiting behavior close to a single fluid regime, capillary pressure can be expressed as a deterministic and non-hysteretic function of fluid saturation, interfacial area between the fluid phases, and the Euler characteristic. This work is unique in the methods employed, the size of the data set, the resolution in space and time, the true equilibrium nature of the data, the parameterizations investigated, and the broad set of functions examined. The conclusion of essentially non-hysteretic behavior provides support for an evolving class of two-fluid-phase flow in porous medium systems models.« less

  8. Engineering Challenges for Closed Ecological System facilities

    NASA Astrophysics Data System (ADS)

    Dempster, William; Nelson, Mark; Allen, John P.

    2012-07-01

    Engineering challenges for closed ecological systems include methods of achieving closure for structures of different materials, and developing methods of allowing energy (for heating and cooling) and information transfer through the materially closed structure. Methods of calculating degree of closure include measuring degradation rates of inert trace gases introduced into the system. An allied problem is developing means of locating where leaks are located so that they may be repaired and degree of closure maintained. Once closure is achieved, methods of dealing with the pressure differentials between inside and outside are needed: from inflatable structures which might adjust to the pressure difference to variable volume chambers attached to the life systems component. These issues are illustrated through the engineering employed at Biosphere 2, the Biosphere 2 Test Module and the Laboratory Biosphere and a discussion of methods used by other closed ecological system facility engineers. Ecological challenges include being able to handle faster cycling rates and accentuated daily and seasonal fluxes of critical life elements such as carbon dioxide, oxygen, water, macro- and mico-nutrients. The problems of achieving sustainability in closed systems for life support include how to handle atmospheric dynamics including trace gases, producing a complete human diet and recycling nutrients and maintaining soil fertility, healthy air and water and preventing the loss of crucial elements from active circulation. In biospheric facilities the challenge is also to produce analogue to natural biomes and ecosystems, studying processes of self-organization and adaptation in systems that allow specification or determination of state variables and cycles which may be followed through all interactions from atmosphere to soils.

  9. A proof-of-concept study of the VeinScrew: A new percutaneous venous closure device.

    PubMed

    Boersma, Doeke; de Borst, Gert Jan; Moll, Frans L

    2017-02-01

    Objective This study evaluated the concept of percutaneous closure of insufficient veins using the VeinScrew principle. Methods The VeinScrew is designed to place a spring-shaped implant that contracts and clamps around the vein. The ability of the device to occlude adequately was tested in a bench model experiment. The feasibility of accurate placement and adequate venous occlusion was evaluated in an animal experiment and in a human cadaveric experiment. Results The VeinScrew implant occluded up to a pressure of 135 mmHg. In vivo studies confirmed that deployment was challenging but technically feasible, and subsequent phlebography showed closure of the vein. The cadaveric study showed that percutaneous placement of the evolved VeinScrew around the great saphenous vein was feasible and accurate. Conclusions The current studies show the feasibility of the VeinScrew concept. Future developments and translational studies are necessary to determine the potential of this technique as a new option in the phlebologist's toolbox.

  10. Asymptotically inspired moment-closure approximation for adaptive networks

    NASA Astrophysics Data System (ADS)

    Shkarayev, Maxim; Shaw, Leah

    2012-02-01

    Adaptive social networks, in which nodes and network structure co-evolve, are often described using a mean-field system of equations for the density of node and link types. These equations constitute an open system due to dependence on higher order topological structures. We propose a moment-closure approximation based on the analytical description of the system in an asymptotic regime. We apply the proposed approach to two examples of adaptive networks: recruitment to a cause model and epidemic spread model. We show a good agreement between the improved mean-field prediction and simulations of the full network system.

  11. Asymptotically inspired moment-closure approximation for adaptive networks

    NASA Astrophysics Data System (ADS)

    Shkarayev, Maxim

    2013-03-01

    Dynamics of adaptive social networks, in which nodes and network structure co-evolve, are often described using a mean-field system of equations for the density of node and link types. These equations constitute an open system due to dependence on higher order topological structures. We propose a systematic approach to moment closure approximation based on the analytical description of the system in an asymptotic regime. We apply the proposed approach to two examples of adaptive networks: recruitment to a cause model and adaptive epidemic model. We show a good agreement between the mean-field prediction and simulations of the full network system.

  12. Asymptotically inspired moment-closure approximation for adaptive networks

    NASA Astrophysics Data System (ADS)

    Shkarayev, Maxim S.; Shaw, Leah B.

    2013-11-01

    Adaptive social networks, in which nodes and network structure coevolve, are often described using a mean-field system of equations for the density of node and link types. These equations constitute an open system due to dependence on higher-order topological structures. We propose a new approach to moment closure based on the analytical description of the system in an asymptotic regime. We apply the proposed approach to two examples of adaptive networks: recruitment to a cause model and adaptive epidemic model. We show a good agreement between the improved mean-field prediction and simulations of the full network system.

  13. Computation of Anisotropic Bi-Material Interfacial Fracture Parameters and Delamination Creteria

    NASA Technical Reports Server (NTRS)

    Chow, W-T.; Wang, L.; Atluri, S. N.

    1998-01-01

    This report documents the recent developments in methodologies for the evaluation of the integrity and durability of composite structures, including i) the establishment of a stress-intensity-factor based fracture criterion for bimaterial interfacial cracks in anisotropic materials (see Sec. 2); ii) the development of a virtual crack closure integral method for the evaluation of the mixed-mode stress intensity factors for a bimaterial interfacial crack (see Sec. 3). Analytical and numerical results show that the proposed fracture criterion is a better fracture criterion than the total energy release rate criterion in the characterization of the bimaterial interfacial cracks. The proposed virtual crack closure integral method is an efficient and accurate numerical method for the evaluation of mixed-mode stress intensity factors.

  14. Prospective, randomized, controlled trial comparing a tissue adhesive (Dermabond™) with adhesive strips (Steri-Strips™) for the closure of laparoscopic trocar wounds in children.

    PubMed

    Romero, P; Frongia, G; Wingerter, S; Holland-Cunz, S

    2011-05-01

    4 methods are used in pediatric laparoscopic surgery to close trocar wounds. While tissue adhesives or adhesive strips have been shown to produce fewer wound complications and a better cosmetic result compared to trans- or only subcutaneous sutures, the choice of technique is still often based on the surgeon's personal experience. Thus, the objective of this trial was to assess the impact of tissue adhesives (Dermabond™) compared to adhesive strips (Steri-Strip™) on potential complications of wound healing, wound pain, cosmetic outcome, and patient satisfaction after laparoscopic appendectomy in children. 49 patients undergoing laparoscopic appendectomy were enrolled in this prospective randomized trial. In every patient, two 5-mm and one 10-mm port-site incision was closed either with Dermabond™ or Steri-Strip™ after placing subcuticular absorbable sutures (4-0 Vicryl™). Postoperative complications, pain, and patient satisfaction with scars were evaluated at follow-up on day 10 and day 90 after the operation using a questionnaire and a visual analogue scale (VAS). Photographs of scars taken on day 90 were evaluated on a VAS by 2 pediatric surgeons blinded to the closure method used. According to the surgeons' evaluation of the cosmetic outcome, a significant difference between the 2 groups with regard to the cosmetic score was found on day 90 of follow-up, favoring Steri-Strip™ wound closure (p < 0.05). On day 10 and 90 there were no statistical differences between the 2 methods as regards the result of patient evaluations (p > 0.05). Only one wound infection (4%) was observed in the Steri-Strip™ group (n = 25) on day 10. At follow-up on day 90 two patients (9.1%) in the Dermabond™ group and one (4.8%) in the Steri-strip™ group complained of wound pain (p = 0.52). Both tissue adhesives and adhesive strips are excellent "no needle" alternatives for the closure of laparoscopic port-site incisions in children. As regards cosmetic outcome, Steri-Strip™ wound closure seems to be the most suitable and is also the less expensive technique. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Density and composition of microorganisms during long-term (418 day) growth of potato using biologically reclaimed nutrients from inedible plant biomass

    NASA Technical Reports Server (NTRS)

    Garland, J. L.; Cook, K. L.; Johnson, M.; Sumner, R.; Fields, N.; Sager, J. C. (Principal Investigator)

    1997-01-01

    A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard 1/2-strength Hoagland's nutrient solution or solutions including nutrients recycled from inedible plant material. The long term effects of closure and recycling on microbial dynamics were evaluated by monitoring the microbial communities associated with various habitats within the plant growth system (i.e., plant roots, nutrient solution, biofilms within the hydroponic systems, atmosphere, and atmospheric condensate). Plate count methods were used to enumerate and characterize microorganisms. Microscopic staining methods were used to estunate total cell densities. The primary finding was that the density and composition of microbial communities associated with controlled environmental plant growth systems are stable during long term operation. Continuous production resulted in slightly greater stability. Nutrient recycling, despite the addition of soluble organic material from the waste processing system, did not significantly increase microbial density in any of the habitats.

  16. Density and composition of microorganisms during long-term (418 day) growth of potato using biologically reclaimed nutrients from inedible plant biomass

    NASA Astrophysics Data System (ADS)

    Garland, J. L.; Cook, K. L.; Johnson, M.; Sumner, R.; Fields, N.

    1997-01-01

    A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard 1/2-strength Hoagland's nutrient solution or solutions including nutrients recycled from inedible plant material. The long term effects of closure and recycling on microbial dynamics were evaluated by monitoring the microbial communities associated with various habitats within the plant growth system (i.e., plant roots, nutrient solution, biofilms within the hydroponic systems, atmosphere, and atmospheric condensate). Plate count methods were used to enumerate and characterize microorganisms. Microscopic staining methods were used to estimate total cell densities. The primary finding was that the density and composition of microbial communities associated with controlled environmental plant growth systems are stable during long term operation. Continuous production resulted in slightly greater stability. Nutrient recycling, despite the addition of soluble organic material from the waste processing system, did not significantly increase microbial density in any of the habitats.

  17. Density and composition of microorganisms during long-term (418 day) growth of potato using biologically reclaimed nutrients from inedible plant biomass

    NASA Astrophysics Data System (ADS)

    1997-01-01

    A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard 12-strength Hoagland's nutrient solution or solutions including nutrients recycled from inedible plant material. The long term effects of closure and recycling on microbial dynamics were evaluated by monitoring the microbial communities associated with various habitats within the plant growth system (i.e., plant roots, nutrient solution, biofilms within the hydroponic systems, atmosphere, and atmospheric condensate). Plate count methods were used to enumerate and characterize microorganisms. Microscopic staining methods were used to estimate total cell densities. The primary finding was that the density and composition of microbial communities associated with controlled environmental plant growth systems are stable during long term operation. Continuous production resulted in slightly greater stability. Nutrient recycling, despite the addition of soluble organic material from the waste processing system, did not significantly increase microbial density in any of the habitats.

  18. An Algebraic Approach to the Study and Optimization of the Set of Rules of a Conditional Rewrite System

    NASA Astrophysics Data System (ADS)

    Makhortov, S. D.

    2018-03-01

    An algebraic system containing the semantics of a set of rules of the conditional equational theory (or the conditional term rewriting system) is introduced. The following basic questions are considered for the given model: existence of logical closure, structure of logical closure, possibility of equivalent transformations, and construction of logical reduction. The obtained results can be applied to the analysis and automatic optimization of the corresponding set of rules. The basis for the given research is the theory of lattices and binary relations.

  19. Cyanoacrylate medical glue application in intervertebral disc annulus defect repair: Mechanical and biocompatible evaluation.

    PubMed

    Kang, Ran; Li, Haisheng; Lysdahl, Helle; Quang Svend Le, Dang; Chen, Menglin; Xie, Lin; Bünger, Cody

    2017-01-01

    In an attempt to find an ideal closure method during annulus defect repair, we evaluate the use of medical glue by mechanical and biocompatible test. Cyanoacrylate medical glue was applied together with a multilayer microfiber/nanofiber polycaprolactone scaffold and suture in annulus repair. Continuous axial loading and fatigue mechanical test was performed. Furthermore, the in vitro response of mesenchymal stem cell (MSC) to the glue was evaluated by cell viability assay. The in vivo response of annulus tissue to the glue and scaffold was also studied in porcine lumbar spine; histological sections were evaluated after 3 months. Cyanoacrylate glue significantly improved the closure effect in the experimental group with failure load 2825.7 ± 941.6 N, compared to 774.1 ± 281.3 N in the control group without glue application (p < 0.01). The experimental group also withstood the fatigue test. No toxic effect was observed by in vitro cell culture and in vivo implantation. On the basis of this initial evaluation, the use of cyanoacrylate medical glue improves closure effect with no toxicity in annulus defect repair. This method of annulus repair merits further effectiveness study in vivo. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 14-20, 2017. © 2015 Wiley Periodicals, Inc.

  20. Dynamic modelling of costs and health consequences of school closure during an influenza pandemic

    PubMed Central

    2012-01-01

    Background The purpose of this article is to evaluate the cost-effectiveness of school closure during a potential influenza pandemic and to examine the trade-off between costs and health benefits for school closure involving different target groups and different closure durations. Methods We developed two models: a dynamic disease model capturing the spread of influenza and an economic model capturing the costs and benefits of school closure. Decisions were based on quality-adjusted life years gained using incremental cost-effectiveness ratios. The disease model is an age-structured SEIR compartmental model based on the population of Oslo. We studied the costs and benefits of school closure by varying the age targets (kindergarten, primary school, secondary school) and closure durations (1–10 weeks), given pandemics with basic reproductive number of 1.5, 2.0 or 2.5. Results The cost-effectiveness of school closure varies depending on the target group, duration and whether indirect costs are considered. Using a case fatality rate (CFR) of 0.1-0.2% and with current cost-effectiveness threshold for Norway, closing secondary school is the only cost-effective strategy, when indirect costs are included. The most cost-effective strategies would be closing secondary schools for 8 weeks if R0=1.5, 6 weeks if R0=2.0, and 4 weeks if R0= 2.5. For severe pandemics with case fatality rates of 1-2%, similar to the Spanish flu, or when indirect costs are disregarded, the optimal strategy is closing kindergarten, primary and secondary school for extended periods of time. For a pandemic with 2009 H1N1 characteristics (mild severity and low transmissibility), closing schools would not be cost-effective, regardless of the age target of school children. Conclusions School closure has moderate impact on the epidemic’s scope, but the resulting disruption to society imposes a potentially great cost in terms of lost productivity from parents’ work absenteeism. PMID:23140513

  1. Assessment of platelet-derived growth factor using A splinted full thickness dermal wound model in bearded dragons (Pogona vitticeps).

    PubMed

    Keller, Krista A; Paul-Murphy, Joanne; Weber, E P Scott; Kass, Philip H; Guzman, Sanchez-Migallon David; Park, Shin Ae; Raghunathan, Vijay Krishna; Gustavsen, Kate A; Murphy, Christopher J

    2014-12-01

    Wounds in reptiles are a common reason for presentation to a veterinarian. At this time there is limited information on effective topical medications to aid in wound closure. The objectives of this study were to translate the splinted, full-thickness dermal wound model, validated in mice, to the bearded dragon (Pogona vitticeps) and to determine the effect of topical becaplermin (BP), a platelet-derived growth factor (0.01%), on the rate of wound closure. Ten bearded dragons were anesthetized and two full-thickness cutaneous wounds were made on the dorsum of each lizard. Encircling splints were applied surrounding each wound and subsequently covered by a semi-occlusive dressing. Five lizards had one wound treated with BP and the adjacent wound treated with a vehicle control. Five additional lizards had one wound treated with saline and the second wound treated with a vehicle control. Wounds were imaged daily, and the wound area was measured using digital image analysis. The change in percentage wound closure over 17 days and the time to 50% wound closure was compared among the four treatment groups. There was no significant difference in wound closure rates between BP-treated and saline-treated wounds or in the time to 50% wound closure between any treatments. Vehicle-treated wounds adjacent to saline-treated wounds closed significantly slower than did BP (P < 0.010), saline (P < 0.001), and vehicle-treated wounds adjacent to BP-treated wounds (P < 0.013). Our preliminary study indicates that the splinted wound model, with modifications, may be used to determine wound closure rates in bearded dragons. When compared with saline, BP did not have a significant effect on wound closure rates, while the vehicle alone delayed wound closure. Histologic analysis of experimentally created wounds throughout the wound healing process is needed to further evaluate the effects of these treatments on reptile dermal wound healing.

  2. Endoscopic full-thickness resection and defect closure in the colon.

    PubMed

    von Renteln, Daniel; Schmidt, Arthur; Vassiliou, Melina C; Rudolph, Hans-Ulrich; Caca, Karel

    2010-06-01

    Endoscopic full-thickness resection (eFTR) is a minimally invasive method for en bloc resection of GI lesions. The aim of this pilot study was to evaluate the feasibility of a grasp-and-snare technique for eFTR combined with an over-the-scope clip (OTSC) for defect closure. Nonsurvival animal study. Animal laboratory. Fourteen female domestic pigs. The eFTR was performed in porcine colons using a novel tissue anchor in combination with a standard monofilament snare and 14 mm OTSC. In the first group (n = 20), closure of the colonic defects with OTSC was attempted after the resection. In the second group (n = 8), an endoloop was used to secure the resection base before eFTR was performed. In the first group (n = 20), eFTR specimens ranged from 2.4 to 5.5 cm in diameter. Successful closure was achieved in 9 out of 20 cases. Mean burst pressure for OTSC closure was 29.2 mm Hg (range, 2-90; SD, 29.92). Injury to adjacent organs occurred in 3 cases. Lumen obstruction due to the OTSC closure occurred in 3 cases. In the second group (n = 8), the diameter of specimens ranged from 1.2 to 2.2 cm. Complete closure was achieved in all cases, with a mean burst pressure of 76.6 mm Hg (range, 35-120; SD, 31). Lumen obstruction due to the endoloop closure occurred in one case. No other complications or injuries were observed in the second group. Nonsurvival setting. Colonic eFTR using the grasp-and-snare technique is feasible in an animal model. Ligation of the resection base with an endoloop before eFTR seems to reduce complication rates and improve closure success and leak test results despite yielding smaller specimens. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  3. Do we need a femoral artery route for transvenous PDA closure in children with ADO-I?

    PubMed

    Baykan, Ali; Narin, Nazmi; Özyurt, Abdullah; Argun, Mustafa; Pamukçu, Özge; Onan, Sertaç H; Sezer, Sadettin; Baykan, Zeynep; Üzüm, Kazım

    2015-03-01

    The standard procedure in percutaneous closure of patent ductus arteriosus (PDA) with Amplatzer duct occluder-I (ADO-I) is transvenous closure guided by aortic access through femoral artery. The current study aims to compare the procedures for PDA closure with ADO-I: only transvenous access with the standard procedure. This study was designed retrospectively and 101 pediatric patients were included. PDA closure was done by only femoral venous access in 19 of them (group 1), arterial and venous access used in 92 patients (group 2) between 2004 to 2012 years. The position of the device and residual shunt in group1 was evaluated by the guidance of the aortogram obtained during the return phase of the pulmonary artery injection and guidance of transthoracic echocardiography. Shapiro-Wilk's test, Mann-Whitney U, chi-squared tests were used for statistical comparison. The procedure was successful in 18 (95%) patients in group 1 and 90 (98%) patients in group 2. Complications including the pulmonary artery embolization (n=1), protrusion to pulmonary artery (n=1), inguinal hematoma (n=3), bleeding (n=2) were only detected in group 2. In other words, while complications were observed in 7 (7.2%) patients in group 2, no minor/major complication was observed in group 1. Complete closure in group 1 was: in catheterization room 14 (77.8%), at 24th hour in 2 (11.1%), at first month in 2 (11.1%). Complete closure in group 2 was: 66 (73.4%) patients in the catheterization room, 21 (23.3%) at 24th hour, 3 (3.3%) at first month, complete closure occurred at the end of first month. In percutaneouse PDA closure via ADO-I, this technique can be a choice for patients whose femoral artery could not be accessed, or access is impossible/contraindicated. But for the reliability and validity of this method, randomized multicenter clinical studies are necessary.

  4. Do we need a femoral artery route for transvenous PDA closure in children with ADO-I?

    PubMed Central

    Baykan, Ali; Narin, Nazmi; Özyurt, Abdullah; Argun, Mustafa; Pamukçu, Özge; Onan, Sertaç H.; Sezer, Sadettin; Baykan, Zeynep; Üzüm, Kazım

    2015-01-01

    Objective: The standard procedure in percutaneous closure of patent ductus arteriosus (PDA) with Amplatzer duct occluder-I (ADO-I) is transvenous closure guided by aortic access through femoral artery. The current study aims to compare the procedures for PDA closure with ADO-I: only transvenous access with the standard procedure. Methods: This study was designed retrospectively and 101 pediatric patients were included. PDA closure was done by only femoral venous access in 19 of them (group 1), arterial and venous access used in 92 patients (group 2) between 2004 to 2012 years. The position of the device and residual shunt in group1 was evaluated by the guidance of the aortogram obtained during the return phase of the pulmonary artery injection and guidance of transthoracic echocardiography. Shapiro-Wilk’s test, Mann-Whitney U, chi-squared tests were used for statistical comparison. Results: The procedure was successful in 18 (95%) patients in group 1 and 90 (98%) patients in group 2. Complications including the pulmonary artery embolization (n=1), protrusion to pulmonary artery (n=1), inguinal hematoma (n=3), bleeding (n=2) were only detected in group 2. In other words, while complications were observed in 7 (7.2%) patients in group 2, no minor/major complication was observed in group 1. Complete closure in group 1 was: in catheterization room 14 (77.8%), at 24th hour in 2 (11.1%), at first month in 2 (11.1%). Complete closure in group 2 was: 66 (73.4%) patients in the catheterization room, 21 (23.3%) at 24th hour, 3 (3.3%) at first month, complete closure occurred at the end of first month. Conclusion: In percutaneouse PDA closure via ADO-I, this technique can be a choice for patients whose femoral artery could not be accessed, or access is impossible/contraindicated. But for the reliability and validity of this method, randomized multicenter clinical studies are necessary. PMID:25333978

  5. The influence of percutaneous closure of patent ductus arteriosus on left ventricular size and function: a prospective study using two- and three-dimensional echocardiography and measurements of serum natriuretic peptides.

    PubMed

    Eerola, Anneli; Jokinen, Eero; Boldt, Talvikki; Pihkala, Jaana

    2006-03-07

    We aimed to evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA) on left ventricular (LV) hemodynamics. Today, most PDAs are closed percutaneously. Little is known, however, about hemodynamic changes after the procedure. Of 37 children (ages 0.6 to 10.6 years) taken to the catheterization laboratory for percutaneous PDA closure, the PDA was closed in 33. Left ventricular diastolic and systolic dimensions, volumes, and function were examined by two-dimensional (2D) and three-dimensional (3D) echocardiography and serum concentrations of natriuretic peptides measured before PDA closure, on the following day, and 6 months thereafter. Control subjects comprised 36 healthy children of comparable ages. At baseline, LV diastolic diameter measured >+2 SD in 5 of 33 patients. In 3D echocardiography, a median LV diastolic volume measured 54.0 ml/m2 in the control subjects and 58.4 ml/m2 (p < 0.05) in the PDA group before closure and 57.2 ml/m2 (p = NS) 6 months after closure. A median N-terminal brain natriuretic peptide (pro-BNP) concentration measured 72 ng/l in the control group and 141 ng/l in the PDA group before closure (p = 0.001) and 78.5 ng/l (p = NS) 6 months after closure. Patients differed from control subjects in indices of LV systolic and diastolic function at baseline. By the end of follow-up, all these differences had disappeared. Even in the subgroup of patients with normal-sized LV at baseline, the LV diastolic volume decreased significantly during follow-up. Changes in LV volume and function caused by PDA disappear by 6 months after percutaneous closure. Even the children with normal-sized LV benefit from the procedure.

  6. Intrinsic frequency for a systems approach to haemodynamic waveform analysis with clinical applications

    PubMed Central

    Pahlevan, Niema M.; Tavallali, Peyman; Rinderknecht, Derek G.; Petrasek, Danny; Matthews, Ray V.; Hou, Thomas Y.; Gharib, Morteza

    2014-01-01

    The reductionist approach has dominated the fields of biology and medicine for nearly a century. Here, we present a systems science approach to the analysis of physiological waveforms in the context of a specific case, cardiovascular physiology. Our goal in this study is to introduce a methodology that allows for novel insight into cardiovascular physiology and to show proof of concept for a new index for the evaluation of the cardiovascular system through pressure wave analysis. This methodology uses a modified version of sparse time–frequency representation (STFR) to extract two dominant frequencies we refer to as intrinsic frequencies (IFs; ω1 and ω2). The IFs are the dominant frequencies of the instantaneous frequency of the coupled heart + aorta system before the closure of the aortic valve and the decoupled aorta after valve closure. In this study, we extract the IFs from a series of aortic pressure waves obtained from both clinical data and a computational model. Our results demonstrate that at the heart rate at which the left ventricular pulsatile workload is minimized the two IFs are equal (ω1 = ω2). Extracted IFs from clinical data indicate that at young ages the total frequency variation (Δω = ω1 − ω2) is close to zero and that Δω increases with age or disease (e.g. heart failure and hypertension). While the focus of this paper is the cardiovascular system, this approach can easily be extended to other physiological systems or any biological signal. PMID:25008087

  7. Pressure disequilibria induced by rapid valve closure in noble gas extraction lines

    USGS Publications Warehouse

    Morgan, Leah; Davidheiser-Kroll, Brett

    2015-01-01

    Pressure disequilibria during rapid valve closures can affect calculated molar quantities for a range of gas abundance measurements (e.g., K-Ar geochronology, (U-Th)/He geochronology, noble gas cosmogenic chronology). Modeling indicates this effect in a system with a 10 L reservoir reaches a bias of 1% before 1000 pipette aliquants have been removed from the system, and a bias of 10% before 10,000 aliquants. Herein we explore the causes and effects of this problem, which is the result of volume changes during valve closure. We also present a solution in the form of an electropneumatic pressure regulator that can precisely control valve motion. This solution reduces the effect to ∼0.3% even after 10,000 aliquants have been removed from a 10 L reservoir.

  8. Pressure disequilibria induced by rapid valve closure in noble gas extraction lines

    NASA Astrophysics Data System (ADS)

    Morgan, Leah E.; Davidheiser-Kroll, Brett

    2015-06-01

    Pressure disequilibria during rapid valve closures can affect calculated molar quantities for a range of gas abundance measurements (e.g., K-Ar geochronology, (U-Th)/He geochronology, noble gas cosmogenic chronology). Modeling indicates this effect in a system with a 10 L reservoir reaches a bias of 1% before 1000 pipette aliquants have been removed from the system, and a bias of 10% before 10,000 aliquants. Herein we explore the causes and effects of this problem, which is the result of volume changes during valve closure. We also present a solution in the form of an electropneumatic pressure regulator that can precisely control valve motion. This solution reduces the effect to ˜0.3% even after 10,000 aliquants have been removed from a 10 L reservoir.

  9. Effect of anticoagulation on endothermal ablation of the great saphenous vein.

    PubMed

    Sharifi, Mohsen; Mehdipour, Mahshid; Bay, Curt; Emrani, Farnaz; Sharifi, Jalaladdin

    2011-01-01

    A growing number of patients who are on systemic anticoagulation with warfarin require endovenous thermal ablation for reflux disease in the great saphenous vein (GSV). Little is known about the effects of anticoagulation on periprocedural bleeding and long-term closure rates of the treated veins. This study evaluated the effects of uninterrupted anticoagulation in patients undergoing endovenous thermal ablation. In this prospective observational study, 88 limbs of patients on warfarin (anticoagulation group [AG]) who underwent endovenous thermal ablation for GSV reflux disease were compared with 92 limbs in patients receiving no anticoagulation or antiplatelet agents (control group [CG]). Forty percent of AG patients were also receiving antiplatelet therapy. Periprocedural bleeding and closure rate at 1 year were evaluated. No major bleeding occurred in either group. Minor bleeding was noted in 8 of 88 procedures in the AG vs 4 of 92 in the CG (P = 0.24); all in patients receiving radiofrequency ablation. Four of the eight minor bleeds in the AG were noted in patients receiving "triple therapy" with warfarin, aspirin, and clopidogrel or ticlopidine. Triple therapy in the AG was associated with a higher risk of minor bleeding compared with the CG (relative risk, 13.0; 95% confidence interval, 4.10-41.19, P < .001). All treated venous segments remained closed at the 1-year follow-up in both groups. In this relatively small, nonrandomized study comparing endovenous thermal ablation in patients with and without warfarin, no differences were found in periprocedural risk of major bleeding or closure rate of the treated venous segments. Minor bleeding was increased in patients receiving triple therapy with warfarin, aspirin, and a thienopyridine who underwent radiofrequency ablation. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  10. EASApprox® skin-stretching system: A secure and effective method to achieve wound closure.

    PubMed

    Song, Mingzhi; Zhang, Zhen; Liu, Tao; Liu, Song; Li, Gang; Liu, Zhaochang; Huang, Jingyang; Chen, Song; Li, Linan; Guo, Li; Qiu, Yang; Wan, Jiajia; Liu, Yuejian; Wu, Tao; Wang, Xiaoyong; Lu, Ming; Wang, Shouyu

    2017-07-01

    Large skin defects are commonly observed in the clinic and have attracted much attention recently. Therefore, finding an effective solution for large skin defects is a global problem. The objective of the present study was to assess the effectiveness of the EASApprox ® skin-stretching system for closing large skin defects. Skin defects (5×5 cm) were created on the forearms of 9 Bama miniature pigs, which were randomly divided into the following three groups: Direct suture, the new EASApprox ® skin-stretching device and Kirschner wires. Microcirculation was assessed before surgery and after wound closure. Following the different treatments, the defects were sutured, and wound healing was assessed based on a clinical score. Furthermore, microscopic and ultramicroscopic structures were evaluated, including collagen, elastic fibers and the microvessel density. Significant differences in the clinical score and microvessel density were observed among the groups. Additionally, the mean length obtained for elastic fibers was larger than that obtained for the other two groups. Finally, the new EASApprox ® skin-stretching device resulted in successful wound management and with only minor side effects on skin histology and microcirculation. Therefore, this method has the potential to be used for healing large skin defects.

  11. An Optimal Frequency in Ca2+ Oscillations for Stomatal Closure Is an Emergent Property of Ion Transport in Guard Cells.

    PubMed

    Minguet-Parramona, Carla; Wang, Yizhou; Hills, Adrian; Vialet-Chabrand, Silvere; Griffiths, Howard; Rogers, Simon; Lawson, Tracy; Lew, Virgilio L; Blatt, Michael R

    2016-01-01

    Oscillations in cytosolic-free Ca(2+) concentration ([Ca(2+)]i) have been proposed to encode information that controls stomatal closure. [Ca(2+)]i oscillations with a period near 10 min were previously shown to be optimal for stomatal closure in Arabidopsis (Arabidopsis thaliana), but the studies offered no insight into their origins or mechanisms of encoding to validate a role in signaling. We have used a proven systems modeling platform to investigate these [Ca(2+)]i oscillations and analyze their origins in guard cell homeostasis and membrane transport. The model faithfully reproduced differences in stomatal closure as a function of oscillation frequency with an optimum period near 10 min under standard conditions. Analysis showed that this optimum was one of a range of frequencies that accelerated closure, each arising from a balance of transport and the prevailing ion gradients across the plasma membrane and tonoplast. These interactions emerge from the experimentally derived kinetics encoded in the model for each of the relevant transporters, without the need of any additional signaling component. The resulting frequencies are of sufficient duration to permit substantial changes in [Ca(2+)]i and, with the accompanying oscillations in voltage, drive the K(+) and anion efflux for stomatal closure. Thus, the frequency optima arise from emergent interactions of transport across the membrane system of the guard cell. Rather than encoding information for ion flux, these oscillations are a by-product of the transport activities that determine stomatal aperture. © 2016 American Society of Plant Biologists. All Rights Reserved.

  12. An Optimal Frequency in Ca2+ Oscillations for Stomatal Closure Is an Emergent Property of Ion Transport in Guard Cells1[CC-BY

    PubMed Central

    Minguet-Parramona, Carla; Hills, Adrian; Vialet-Chabrand, Silvere; Griffiths, Howard; Lawson, Tracy; Lew, Virgilio L.; Blatt, Michael R.

    2016-01-01

    Oscillations in cytosolic-free Ca2+ concentration ([Ca2+]i) have been proposed to encode information that controls stomatal closure. [Ca2+]i oscillations with a period near 10 min were previously shown to be optimal for stomatal closure in Arabidopsis (Arabidopsis thaliana), but the studies offered no insight into their origins or mechanisms of encoding to validate a role in signaling. We have used a proven systems modeling platform to investigate these [Ca2+]i oscillations and analyze their origins in guard cell homeostasis and membrane transport. The model faithfully reproduced differences in stomatal closure as a function of oscillation frequency with an optimum period near 10 min under standard conditions. Analysis showed that this optimum was one of a range of frequencies that accelerated closure, each arising from a balance of transport and the prevailing ion gradients across the plasma membrane and tonoplast. These interactions emerge from the experimentally derived kinetics encoded in the model for each of the relevant transporters, without the need of any additional signaling component. The resulting frequencies are of sufficient duration to permit substantial changes in [Ca2+]i and, with the accompanying oscillations in voltage, drive the K+ and anion efflux for stomatal closure. Thus, the frequency optima arise from emergent interactions of transport across the membrane system of the guard cell. Rather than encoding information for ion flux, these oscillations are a by-product of the transport activities that determine stomatal aperture. PMID:26628748

  13. Over the scope clip: technique and expanding clinical applications.

    PubMed

    Singhal, Shashideep; Changela, Kinesh; Papafragkakis, Haris; Anand, Sury; Krishnaiah, Mahesh; Duddempudi, Sushil

    2013-10-01

    Advances in endoscopic and surgical techniques have increased the frequency and complexity of these procedures, and thus, the incidence of associated complications. To describe the use and clinical applications of the Over the Scope Clip (OTSC) system. An English language literature search was conducted using the key words "endoscopy" and "over the scope clip" in order to identify human studies evaluating the application of OTSC from January 2001 to August 2012. The indication, efficacy, complications, and limitations were recorded. Overall success rates of OTSC based on current literature range are in the range of 75% to 100% for closure of iatrogenic gastrointestinal perforations, 38% to 100% for closure of gastrointestinal fistulas, 50% to 100% for anastomotic leaks, and 71% to 100% for bleeding lesions. OTSCs have shown 100% success rates in managing postbariatric surgery weight gain secondary to dilation of the gastrojejunal pouch. OTSC is easy to use with good results, thus decreasing the morbidity and mortality associated with the complications secondary to both diagnostic and therapeutic endoscopy and avoiding surgery in many situations.

  14. Autophagy can promote but is not required for epithelial cell extrusion in the amnioserosa of the Drosophila embryo.

    PubMed

    Cormier, Olga; Mohseni, Nilufar; Voytyuk, Iryna; Reed, Bruce H

    2012-02-01

    During Drosophila embryogenesis the majority of the extra-embryonic epithelium known as the amnioserosa (AS) undergoes programmed cell death (PCD) following the completion of the morphogenetic process of dorsal closure. Approximately ten percent of AS cells, however, are eliminated during dorsal closure by extrusion from the epithelium. Using biosensors that report autophagy and caspase activity in vivo, we demonstrate that AS cell extrusion occurs in the context of elevated autophagy and caspase activation. Furthermore, we evaluate AS extrusion rates, autophagy, and caspase activation in embryos in which caspase activity or autophagy are altered by genetic manipulation. This includes using the GAL4/UAS system to drive expression of p35, reaper, dINR (ACT) and Atg1 in the AS; we also analyze embryos lacking both maternal and zygotic expression of Atg1. Based on our results we suggest that autophagy can promote, but is not required for, epithelial extrusion and caspase activation in the amnioserosa.

  15. Immediate tight sealing of skin incisions using an innovative temperature-controlled laser soldering device: in vivo study in porcine skin.

    PubMed

    Simhon, David; Halpern, Marisa; Brosh, Tamar; Vasilyev, Tamar; Ravid, Avi; Tennenbaum, Tamar; Nevo, Zvi; Katzir, Abraham

    2007-02-01

    A feedback temperature-controlled laser soldering system (TCLS) was used for bonding skin incisions on the backs of pigs. The study was aimed: 1) to characterize the optimal soldering parameters, and 2) to compare the immediate and long-term wound healing outcomes with other wound closure modalities. A TCLS was used to bond the approximated wound margins of skin incisions on porcine backs. The reparative outcomes were evaluated macroscopically, microscopically, and immunohistochemically. The optimal soldering temperature was found to be 65 degrees C and the operating time was significantly shorter than with suturing. The immediate tight sealing of the wound by the TCLS contributed to rapid, high quality wound healing in comparison to Dermabond or Histoacryl cyanoacrylate glues or standard suturing. TCLS of incisions in porcine skin has numerous advantages, including rapid procedure and high quality reparative outcomes, over the common standard wound closure procedures. Further studies with a variety of skin lesions are needed before advocating this technique for clinical use.

  16. Cost savings associated with prevention of recurrent lumbar disc herniation with a novel annular closure device: a multicenter prospective cohort study.

    PubMed

    Parker, Scott L; Grahovac, Gordan; Vukas, Duje; Ledic, Darko; Vilendecic, Milorad; McGirt, Matthew J

    2013-09-01

    Same-level recurrent disc herniation is a well-defined complication following lumbar discectomy. Reherniation results in increased morbidity and health care costs. Techniques to reduce these consequences may improve outcomes and reduce cost after lumbar discectomy. In a prospective cohort study, we set out to evaluate the cost associated with surgical management of recurrent, same-level lumbar disc herniation following primary discectomy. Forty-six consecutive European patients undergoing lumbar discectomy for a single-level herniated disc at two institutions were prospectively followed with clinical and radiographic evaluations. A second consecutive cohort of 30 patients undergoing 31 lumbar discectomies with implantation of an annular closure device was followed at the same hospitals and same follow-up intervals. Cost estimates for reherniation were modeled on Medicare national allowable payment amounts (direct cost) and patient work-day losses (indirect cost). Annular closure and control cohorts were matched at baseline. By 2 years follow-up, symptomatic recurrent same-level disc herniation occurred in three (6.5%) patients in the control cohort versus zero (0%) patients in the annular closure cohort. For patients experiencing recurrent disc herniation, mean estimated direct and indirect cost of management of recurrent disc herniation was $34,242 and $3,778, respectively. Use of an annular closure device potentially results in a cost savings of $222,573 per 100 primary discectomy procedures performed (or $2,226 per discectomy), based solely on the reduction of reoperated reherniations when modeled on U.S. Medicare costs. Recurrent disc herniation did not occur in any patients after annular closure within the 12-month follow-up. The reduction in the incidence of reherniation was associated with potentially significant cost savings. Development of novel techniques to prevent recurrent lumbar disc herniation is warranted to decrease the associated morbidity and health care costs associated with this complication. Georg Thieme Verlag KG Stuttgart · New York.

  17. Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results

    PubMed Central

    Sinha, Santosh Kumar; Razi, Mahmadula; Pandey, Rama Niwas; Kumar, Prakash; Krishna, Vinay; Jha, Mukesh Jitendra; Mishra, Vikas; Asif, Mohammad; Abdali, Nasar; Tewari, Pradyot; Thakur, Ramesh; Pandey, Umeshwar; Varma, Chandra Mohan

    2017-01-01

    Objective: To evaluate the feasibility, safety, and efficacy of a novel Cocoon Duct Occluder device for the transcatheter closure (TCC) of large patent ductus arteriosus (PDA). Methods: In this prospective, non-randomized study, consecutive patients with large PDA (narrowest diameter: ≥3.5/4.0 mm in symptomatic/asymptomatic patients, respectively), who underwent TCC with Cocoon Duct Occluder at our institute between November, 2012 and June, 2016 were examined. TCC was performed using the standard technique, and devices were antegradely delivered via 6–10F delivery sheaths. Device embolization, residual shunt, hemolysis, left pulmonary artery (LPA) stenosis, procedural and fluoroscopy time, and mortality were assessed. Patients were followed-up by transthoracic echocardiography with color Doppler imaging at 24 h (D1), 1 month (D30), and 6 months (D180) after implantation. Results: A total of 57 patients (age: 11.7±2.8 years; weight: 22.3±3.5 kg) were enrolled. The mean narrowest diameter was 7.4±0.7 mm. The PDA closure was successfully performed in each patient. Fluoroscopy and procedural time was 6.7±3.2 min and 23.9±2.7 min, respectively. Postprocedural angiography revealed that 49 (85.9%) patients had immediate and complete closure, whereas 8 (14.1%) had residual shunt. Color Doppler imaging at D1 revealed complete closure in 52 (91.3%) patients. At D30, complete closure was reported in all patients and was maintained at D180. Hemolysis, embolization, obstruction of LPA or descending aorta, and death were not reported till D180. Conclusion: TCC using Cocoon Duct Occluder is feasible, safe, and effective in the management of patients with large PDA, with excellent results on short- and medium-term follow-up. PMID:29145233

  18. Effectiveness of a new gelatin sealant system for dural closure.

    PubMed

    Kawai, Hisashi; Nakagawa, Ichiro; Nishimura, Fumihiko; Motoyama, Yasushi; Park, Young-Su; Nakamura, Mitsutoshi; Nakase, Hiroyuki; Suzuki, Shuko; Ikada, Yoshito

    2014-10-01

    Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage. The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n  =  20), fibrin glue (n  =  20), or a polyethylene glycol (PEG)-based hydrogel sealant (n  =  20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n  =  5) or gelatin glue sealant (n  =  5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated. The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P < 0·001) or the PEG-based hydrogel sealant (46·3 ± 20·9 mmHg, P  =  0·007). Bonding strength was higher for the gelatin glue than fibrin glue (P < 0·001) or PEG-based hydrogel sealant (P  =  0·001). The maximum intracranial pressure in the in vivo model was higher for the gelatin glue group (59·0 ± 2·2 mmHg) than the control group (13·8 ± 4·0 mmHg, P < 0·001). Tissue adhesion was lower for the gelatin glue group than the control group (P  =  0·005). The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.

  19. Flexible, liquid core light guide with focusing and light shaping attachments

    DOEpatents

    Wojcik, Randolph Frank; Majewski, Stanislaw; Zorn, Carl John; Kross, Brian

    1999-01-01

    A liquid light guide system for ultraviolet light is disclosed that has a light shaping arrangement for the emitted light, a stable liquid core and sheath and reliable and effective end closures. The end closures include a metal crimping arrangement that utilizes two layers of deformable materials to prevent cracking of endplugs.

  20. 77 FR 59883 - Magnuson-Stevens Fishery Conservation and Management Act Provisions; Fisheries of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-01

    ... are operating without a yellowtail flounder closure cap for the first time. The scallop fleet continues to use a proactive, near real-time system for avoiding yellowtail flounder; however, the negative... AM for GB yellowtail flounder implements time and area closures based on the magnitude of the overage...

  1. Education: The "Business" of America

    ERIC Educational Resources Information Center

    Ahmed, Nuwar

    2013-01-01

    This article offers the author's views about the business aspects of school administration in the U.S., and discusses the mass school closures in Washington, D.C., New York City, and Chicago. These closures were intended to improve the educational systems within those cities, yet none have benefited from these reforms. She also explains the…

  2. 50 CFR 36.16 - Closure to subsistence uses of fish and wildlife.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 9 2014-10-01 2014-10-01 false Closure to subsistence uses of fish and wildlife. 36.16 Section 36.16 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM ALASKA NATIONAL WILDLIFE REFUGES...

  3. 50 CFR 36.16 - Closure to subsistence uses of fish and wildlife.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Closure to subsistence uses of fish and wildlife. 36.16 Section 36.16 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM ALASKA NATIONAL WILDLIFE REFUGES...

  4. 50 CFR 36.16 - Closure to subsistence uses of fish and wildlife.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 9 2013-10-01 2013-10-01 false Closure to subsistence uses of fish and wildlife. 36.16 Section 36.16 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM ALASKA NATIONAL WILDLIFE REFUGES...

  5. 50 CFR 36.16 - Closure to subsistence uses of fish and wildlife.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Closure to subsistence uses of fish and wildlife. 36.16 Section 36.16 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM ALASKA NATIONAL WILDLIFE REFUGES...

  6. 50 CFR 36.16 - Closure to subsistence uses of fish and wildlife.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false Closure to subsistence uses of fish and wildlife. 36.16 Section 36.16 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM ALASKA NATIONAL WILDLIFE REFUGES...

  7. Formulation and closure of compressible turbulence equations in the light of kinetic theory

    NASA Technical Reports Server (NTRS)

    Tsuge, S.; Sagara, K.

    1976-01-01

    Fluid-dynamic moment equations, based on a kinetic hierarchy system, are derived governing the interaction between turbulent and thermal fluctuations. The kinetic theory is shown to reduce the inherent complexity of the conventional formalism of compressible turbulence theory and to minimize arbitrariness in formulating the closure condition.

  8. Achieving and documenting closure in plant growth facilities

    NASA Technical Reports Server (NTRS)

    Knott, W. M.; Sager, John C.; Wheeler, Ray

    1992-01-01

    As NASA proceeds with its effort to develop a Controlled Ecological Life Support System (CELSS) that will provide life support to crews during long duration space missions, it must address the question of facility and system closure. The concept of closure as it pertains to CELSS and engineering specifications, construction problems and monitoring procedures used in the development and operation of a closed plant growth facility for the CELSS program are described. A plant growth facility is one of several modules required for a CELSS. A prototype of this module at Kennedy Space Center is the large (7m tall x 3.5m diameter) Biomass Production Chamber (BPC), the central facility of the CELSS Breadboard Project. The BPC is atmospherically sealed to a leak rate of approximately 5 percent of its total volume per 24 hours. This paper will discuss the requirements for atmospheric closure in the facility, present CO2 and trace gas data from initial tests of the BPC with and without plants, and describe how the chamber was sealed atmospherically. Implications that research conducted in this type of facility will have for the CELSS program are discussed.

  9. Fetal omphalocele ratios predict outcomes in prenatally diagnosed omphalocele.

    PubMed

    Montero, Freddy J; Simpson, Lynn L; Brady, Paula C; Miller, Russell S

    2011-09-01

    The objective of the study was to evaluate whether ratios considering omphalocele diameter relative to fetal biometric measurements perform better than giant omphalocele designation at predicting inability to achieve neonatal primary surgical closure. Cases of fetal omphalocele that underwent evaluation between May 2003 and July 2010 were identified. Inclusion was restricted to live births with plan for postnatal repair. Omphalocele diameter upon antenatal ultrasound was compared with abdominal circumference, femur length, and head circumference, yielding the respective omphalocele (O)/abdominal circumference (AC), O/femur length (FL), and O/head circumference (HC) ratios. The absolute measurements were used to classify giant lesions. Omphalocele ratios and giant omphalocele designations were evaluated as predictors of inability to achieve primary repair. Among 25 included cases, staged or delayed closure occurred in 52%. With an optimal cutoff of 0.21 or greater, O/HC best predicted the primary outcome (sensitivity, 84.6%; specificity, 58.3%; odds ratio, 7.7). The O/HC of 0.21 or greater outperformed giant designations. The O/HC of 0.21 or greater best predicted staged or delayed omphalocele closure. Giant omphalocele designation, regardless of definition, poorly predicted outcome. Copyright © 2011 Mosby, Inc. All rights reserved.

  10. Assessment of dynamic closure for premixed combustion large eddy simulation

    NASA Astrophysics Data System (ADS)

    Langella, Ivan; Swaminathan, Nedunchezhian; Gao, Yuan; Chakraborty, Nilanjan

    2015-09-01

    Turbulent piloted Bunsen flames of stoichiometric methane-air mixtures are computed using the large eddy simulation (LES) paradigm involving an algebraic closure for the filtered reaction rate. This closure involves the filtered scalar dissipation rate of a reaction progress variable. The model for this dissipation rate involves a parameter βc representing the flame front curvature effects induced by turbulence, chemical reactions, molecular dissipation, and their interactions at the sub-grid level, suggesting that this parameter may vary with filter width or be a scale-dependent. Thus, it would be ideal to evaluate this parameter dynamically by LES. A procedure for this evaluation is discussed and assessed using direct numerical simulation (DNS) data and LES calculations. The probability density functions of βc obtained from the DNS and LES calculations are very similar when the turbulent Reynolds number is sufficiently large and when the filter width normalised by the laminar flame thermal thickness is larger than unity. Results obtained using a constant (static) value for this parameter are also used for comparative evaluation. Detailed discussion presented in this paper suggests that the dynamic procedure works well and physical insights and reasonings are provided to explain the observed behaviour.

  11. MEANS: python package for Moment Expansion Approximation, iNference and Simulation.

    PubMed

    Fan, Sisi; Geissmann, Quentin; Lakatos, Eszter; Lukauskas, Saulius; Ale, Angelique; Babtie, Ann C; Kirk, Paul D W; Stumpf, Michael P H

    2016-09-15

    Many biochemical systems require stochastic descriptions. Unfortunately these can only be solved for the simplest cases and their direct simulation can become prohibitively expensive, precluding thorough analysis. As an alternative, moment closure approximation methods generate equations for the time-evolution of the system's moments and apply a closure ansatz to obtain a closed set of differential equations; that can become the basis for the deterministic analysis of the moments of the outputs of stochastic systems. We present a free, user-friendly tool implementing an efficient moment expansion approximation with parametric closures that integrates well with the IPython interactive environment. Our package enables the analysis of complex stochastic systems without any constraints on the number of species and moments studied and the type of rate laws in the system. In addition to the approximation method our package provides numerous tools to help non-expert users in stochastic analysis. https://github.com/theosysbio/means m.stumpf@imperial.ac.uk or e.lakatos13@imperial.ac.uk Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.

  12. Formation of higher plant component microbial community in closed ecological system

    NASA Astrophysics Data System (ADS)

    Tirranen, L. S.

    2001-07-01

    Closed ecological systems (CES) place at the disposal of a researcher unique possibilities to study the role of microbial communities in individual components and of the entire system. The microbial community of the higher plant component has been found to form depending on specific conditions of the closed ecosystem: length of time the solution is reused, introduction of intrasystem waste water into the nutrient medium, effect of other component of the system, and system closure in terms of gas exchange. The higher plant component formed its own microbial complex different from that formed prior to closure. The microbial complex of vegetable polyculture is more diverse and stable than the monoculture of wheat. The composition of the components' microflora changed, species diversity decreased, individual species of bacteria and fungi whose numbers were not so great before the closure prevailed. Special attention should be paid to phytopathogenic and conditionally pathogenic species of microorganisms potentially hazardous to man or plants and the least controlled in CES. This situation can endanger creation of CES and make conjectural existence of preplanned components, man, specifically, and consequently, of CES as it is.

  13. Novel dural closure technique using polyglactin acid sheet prevents cerebrospinal fluid leakage after spinal surgery.

    PubMed

    Sugawara, Taku; Itoh, Yasunobu; Hirano, Yoshitaka; Higashiyama, Naoki; Shimada, Yoichi; Kinouchi, Hiroyuki; Mizoi, Kazuo

    2005-10-01

    Extradural or subcutaneous cerebrospinal fluid (CSF) leakage is a common complication after spinal surgery and is associated with the risks of poor wound healing, meningitis, and pseudomeningocele. Numerous methods to prevent postoperative CSF leakage are available, but pressure-tight dural closure remains difficult, especially with synthetic surgical membranes. The efficacy of a novel dural closure technique was assessed by detecting extradural or subcutaneous CSF leakage on magnetic resonance imaging. The novel dural closure technique using absorbable polyglactin acid sheet and fibrin glue and the conventional procedure using only fibrin glue were evaluated retrospectively by identifying extradural or subcutaneous CSF leakage on magnetic resonance imaging scans in the acute (2-7 d) and chronic (3-6 mo) postoperative stages after spinal intradural surgery in 53 patients. The incidence of extradural and subcutaneous CSF leakage was significantly lower (P < 0.05) in the acute (20%) and chronic (0%) stages using polyglactin acid sheet and fibrin glue in 15 patients compared with that in the acute (81%) and chronic (24%) stages using only fibrin glue in 38 patients. One patient in the fibrin glue-only group required repair surgery for cutaneous CSF leakage. The combination of polyglactin acid sheet and fibrin glue can achieve water-tight closure after spinal intradural surgery and can minimize the risk of intractable postoperative CSF leakage. This simple, economical technique is recommended for dural closure after spinal intradural surgery.

  14. Current topics in surgery for multiple ventricular septal defects.

    PubMed

    Yoshimura, Naoki; Fukahara, Kazuaki; Yamashita, Akio; Doki, Yoshinori; Takeuchi, Katsunori; Higuma, Tomonori; Senda, Kazutaka; Toge, Masayoshi; Matsuo, Tatsuro; Nagura, Saori; Aoki, Masaya; Sakata, Kimimasa; Sakai, Mari

    2016-04-01

    In this review article, we describe several topics, including the sandwich technique, the transatrial re-endocardialization technique, the limited apical left ventriculotomy approach and device closure. The sandwich technique was introduced for the closure of muscular ventricular septal defects (VSD) by sandwiching the septum between two felt patches placed in the left and right ventricle. This technique requires neither the transection of muscular trabeculae nor ventriculotomy. Although the sandwich technique has resulted in the improvement of surgical outcomes, cases of postoperative cardiac dysfunction have been reported. Multiple smaller VSDs have been closed with transatrial re-endocardialization. Septal dysfunction may be avoided through this technique, in which the septal trabeculae are approximated in two layers of superficial, endocardial running sutures. Recently, a number of reports have recommended a limited apical left ventriculotomy approach. With this technique, a much shorter incision of around 1 cm at the apex of the left ventricle may be sufficient for achieving the complete closure of apical muscular VSDs. The transcatheter or perventricular device closure of muscular VSDs has increasingly been performed with good results. Although favorable early and mid-term results of device closure have been reported, this method is not always safer or less invasive than surgical closure. Long-term evaluations should be performed to determine whether the right and left ventricular functions are affected by treatment with relatively large devices in the heart.

  15. Simple Skin-Stretching Device in Assisted Tension-Free Wound Closure.

    PubMed

    Cheng, Li-Fu; Lee, Jiunn-Tat; Hsu, Honda; Wu, Meng-Si

    2017-03-01

    Numerous conventional wound reconstruction methods, such as wound undermining with direct suture, skin graft, and flap surgery, can be used to treat large wounds. The adequate undermining of the skin flaps of a wound is a commonly used technique for achieving the closure of large tension wounds; however, the use of tension to approximate and suture the skin flaps can cause ischemic marginal necrosis. The purpose of this study is to use elastic rubber bands to relieve the tension of direct wound closure for simultaneously minimizing the risks of wound dehiscence and wound edge ischemia that lead to necrosis. This retrospective study was conducted to evaluate our clinical experiences with 22 large wounds, which involved performing primary closures under a considerable amount of tension by using elastic rubber bands in a skin-stretching technique after a wide undermining procedure. Assessment of the results entailed complete wound healing and related complications. All 22 wounds in our study showed fair to good results except for one. The mean success rate was approximately 95.45%. The simple skin-stretching design enabled tension-free skin closure, which pulled the bilateral undermining skin flaps as bilateral fasciocutaneous advancement flaps. The skin-stretching technique was generally successful.

  16. Actomyosin purse strings: renewable resources that make morphogenesis robust and resilient

    PubMed Central

    Rodriguez-Diaz, Alice; Toyama, Yusuke; Abravanel, Daniel L.; Wiemann, John M.; Wells, Adrienne R.; Tulu, U. Serdar; Edwards, Glenn S.; Kiehart, Daniel P.

    2008-01-01

    Dorsal closure in Drosophila is a model system for cell sheet morphogenesis and wound healing. During closure two sheets of lateral epidermis move dorsally to close over the amnioserosa and form a continuous epidermis. Forces from the amnioserosa and actomyosin-rich, supracellular purse strings at the leading edges of these lateral epidermal sheets drive closure. Purse strings generate the largest force for closure and occur during development and wound healing throughout phylogeny. We use laser microsurgery to remove some or all of the purse strings from developing embryos. Free edges produced by surgery undergo characteristic responses as follows. Intact cells in the free edges, which previously had no purse string, recoil away from the incision and rapidly assemble new, secondary purse strings. Next, recoil slows, then pauses at a turning point. Following a brief delay, closure resumes and is powered to completion by the secondary purse strings. We confirm that the assembly of the secondary purse strings requires RhoA. We show that α-actinin alternates with nonmuscle myosin II along purse strings and requires nonmuscle myosin II for its localization. Together our data demonstrate that purse strings are renewable resources that contribute to the robust and resilient nature of closure. PMID:19404432

  17. A nonlocal fluid closure for antiparallel reconnection

    NASA Astrophysics Data System (ADS)

    Ng, J.; Hakim, A.; Bhattacharjee, A.

    2016-12-01

    The integration of kinetic effects in fluid models is an important problem in global simulations of the Earth's magnetosphere and space weather modelling. In particular, it has been shown that ion kinetics play an important role in the dynamics of large reconnecting systems, and that fluid models can account of some of these effects[1,2] . Here we introduce a new fluid model and closure for collisionless magnetic reconnection and more general applications. Taking moments of the kinetic equation, we evolve the full pressure tensor for electrons and ions, which includes the off diagonal terms necessary for reconnection. Kinetic effects are recovered by using a nonlocal heat flux closure, which approximates linear Landau damping in the fluid framework [3]. Using the island coalescence problem as a test, we show how the nonlocal ion closure improves on the typical collisional closures used for ten-moment models and circumvents the need for a colllisional free parameter. Finally, we extend the closure to study guide-field reconnection and discuss the implementation of a twenty-moment model.[1] A. Stanier et al. Phys Rev Lett (2015)[2] J. Ng et al. Phys Plasmas (2015)[3] G. Hammett et al. Phys Rev Lett (1990)

  18. Analysis on influence of guide vanes closure laws of pump-turbine on load rejection transient process

    NASA Astrophysics Data System (ADS)

    Yao, Z.; Bi, H. L.; Huang, Q. S.; Li, Z. J.; Wang, Z. W.

    2013-12-01

    In load rejection transient process, the sudden shut down of guide vanes may cause units speed rise and a sharp increase in water hammer pressure of diversion system, which endangers the safety operation of the power plant. Adopting reasonable guide vane closure law is a kind of economic and effective measurement to reduce the water hammer pressure and limit rotational speed increases. In this paper, combined with Guangzhou Pumped Storage Power Station plant A, the load rejection condition under different guide vanes closure laws is calculated and the key factor of guide vanes closure laws on the impact of the load rejection transition process is analyzed. The different inflection points, which are the closure modes, on the impact of unit speed change, water level fluctuation of surge tank, and the pressure fluctuation of volute inlet and draft tube inlet are further discussed. By compared with the calculation results, a reasonable guide vanes inflection point position can be determined according to security requirements and a reasonable guide vanes closure law can be attained to effectively coordinate the unit speed rise and the rapid pressure change in the load rejection transient process.

  19. Pre/post-closure assessment of groundwater pharmaceutical fate in a wastewater-facility-impacted stream reach.

    PubMed

    Bradley, Paul M; Barber, Larry B; Clark, Jimmy M; Duris, Joseph W; Foreman, William T; Furlong, Edward T; Givens, Carrie E; Hubbard, Laura E; Hutchinson, Kasey J; Journey, Celeste A; Keefe, Steffanie H; Kolpin, Dana W

    2016-10-15

    Pharmaceutical contamination of contiguous groundwater is a substantial concern in wastewater-impacted streams, due to ubiquity in effluent, high aqueous mobility, designed bioactivity, and to effluent-driven hydraulic gradients. Wastewater treatment facility (WWTF) closures are rare environmental remediation events; offering unique insights into contaminant persistence, long-term wastewater impacts, and ecosystem recovery processes. The USGS conducted a combined pre/post-closure groundwater assessment adjacent to an effluent-impacted reach of Fourmile Creek, Ankeny, Iowa, USA. Higher surface-water concentrations, consistent surface-water to groundwater concentration gradients, and sustained groundwater detections tens of meters from the stream bank demonstrated the importance of WWTF effluent as the source of groundwater pharmaceuticals as well as the persistence of these contaminants under effluent-driven, pre-closure conditions. The number of analytes (110 total) detected in surface water decreased from 69 prior to closure down to 8 in the first post-closure sampling event approximately 30 d later, with a corresponding 2 order of magnitude decrease in the cumulative concentration of detected analytes. Post-closure cumulative concentrations of detected analytes were approximately 5 times higher in proximal groundwater than in surface water. About 40% of the 21 contaminants detected in a downstream groundwater transect immediately before WWTF closure exhibited rapid attenuation with estimated half-lives on the order of a few days; however, a comparable number exhibited no consistent attenuation during the year-long post-closure assessment. The results demonstrate the potential for effluent-impacted shallow groundwater systems to accumulate pharmaceutical contaminants and serve as long-term residual sources, further increasing the risk of adverse ecological effects in groundwater and the near-stream ecosystem. Published by Elsevier B.V.

  20. Modified closure technique for reducing sternal dehiscence; a clinical and in vitro assessment.

    PubMed

    John, Lindsay C H

    2008-05-01

    Although the incidence of sternal dehiscence is low its mortality can be high. An alternative technique is described (modified closure) which aims to redistribute the dehiscence force into the longer longitudinal axis rather than the shorter transverse axis, thereby maximising the closure strength. Four ethibond sutures, which interlock anteriorly, are used in addition to eight transverse sternal wires. The aim of the study was to assess the modified closure using both an in vitro and a clinical study. (a) In vitro study: A weight and traction pulley system applied a force of 0.1kN to pairs of silicone rubber hemisterna approximated to each other using alternative closure techniques. The dehiscence tendency (DT) was measured as the amount of separation under tension. Using 10 pairs of hemisterna for each closure technique the measured DT for the modified closure (MC) was compare with those for each of five alternative closures (two figure-of-eight and four transverse sutures (2C), 6 (6T), 8 (8T), 10 (10T) and 12 transverse sutures (12T)). (b) Clinical study: The incidence of sternal dehiscence for the first 4 years of a consultants' practice (using 8T) was compared with the second 4 years (using MC). (a) Measured DT (mean+/-SEM), (MC: 149+/-14; 6T: 256+/-13; 8T: 223+/-9; 10T: 213+/-13; 12T: 203+/-8; 2C: 294+/-15). DT was significantly smaller for MC (p<0.003). (b) The incidence of dehiscence was significantly smaller in the second 4 years (MC) than in the first (8T): 0.2% (1/529) versus 1.6% (13/788); p=0.01 In vitro and clinical studies suggest that the modified closure technique can reduce the incidence of sternal dehiscence.

  1. Dissipative closures for statistical moments, fluid moments, and subgrid scales in plasma turbulence

    NASA Astrophysics Data System (ADS)

    Smith, Stephen Andrew

    1997-11-01

    Closures are necessary in the study physical systems with large numbers of degrees of freedom when it is only possible to compute a small number of modes. The modes that are to be computed, the resolved modes, are coupled to unresolved modes that must be estimated. This thesis focuses on dissipative closures models for two problems that arises in the study of plasma turbulence: the fluid moment closure problem and the subgrid scale closure problem. The fluid moment closures of Hammett and Perkins (1990) were originally applied to a one-dimensional kinetic equation, the Vlasov equation. These closures are generalized in this thesis and applied to the stochastic oscillator problem, a standard paradigm problem for statistical closures. The linear theory of the Hammett- Perkins closures is shown to converge with increasing numbers of moments. A novel parameterized hyperviscosity is proposed for two- dimensional drift-wave turbulence. The magnitude and exponent of the hyperviscosity are expressed as functions of the large scale advection velocity. Traditionally hyperviscosities are applied to simulations with a fixed exponent that must be arbitrarily chosen. Expressing the exponent as a function of the simulation parameters eliminates this ambiguity. These functions are parameterized by comparing the hyperviscous dissipation to the subgrid dissipation calculated from direct numerical simulations. Tests of the parameterization demonstrate that it performs better than using no additional damping term or than using a standard hyperviscosity. Heuristic arguments are presented to extend this hyperviscosity model to three-dimensional (3D) drift-wave turbulence where eddies are highly elongated along the field line. Preliminary results indicate that this generalized 3D hyperviscosity is capable of reducing the resolution requirements for 3D gyrofluid turbulence simulations.

  2. Suitability of Exoseal Vascular Closure Device for Antegrade Femoral Artery Puncture Site Closure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Liebl, Andrea; Poullos, Nektarios

    Purpose. To assess the efficacy and safety of the Exoseal vascular closure device for antegrade puncture of the femoral artery. Methods. In a prospective study from February 2011 to January 2012, a total of 93 consecutive patients received a total of 100 interventional procedures via an antegrade puncture of the femoral artery. An Exoseal vascular closure device (6F) was used for closure in all cases. Puncture technique, duration of manual compression, and use of compression bandages were documented. All patients were monitored by vascular ultrasound and color-coded duplex sonography of their respective femoral artery puncture site within 12 to 36more » h after angiography to check for vascular complications. Results. In 100 antegrade interventional procedures, the Exoseal vascular closure device was applied successfully for closure of the femoral artery puncture site in 96 cases (96 of 100, 96.0 %). The vascular closure device could not be deployed in one case as a result of kinking of the vascular sheath introducer and in three cases because the bioabsorbable plug was not properly delivered to the extravascular space adjacent to the arterial puncture site, but instead fully removed with the delivery system (4.0 %). Twelve to 36 h after the procedure, vascular ultrasound revealed no complications at the femoral artery puncture site in 93 cases (93.0 %). Minor vascular complications were found in seven cases (7.0 %), with four cases (4.0 %) of pseudoaneurysm and three cases (3.0 %) of significant late bleeding, none of which required surgery. Conclusion. The Exoseal vascular closure device was safely used for antegrade puncture of the femoral artery, with a high rate of procedural success (96.0 %), a low rate of minor vascular complications (7.0 %), and no major adverse events.« less

  3. Urethral pressure reflectometry during intra-abdominal pressure increase-an improved technique to characterize the urethral closure function in continent and stress urinary incontinent women.

    PubMed

    Saaby, Marie-Louise; Klarskov, Niels; Lose, Gunnar

    2013-11-01

    to assess the urethral closure function by urethral pressure reflectometry (UPR) during intra-abdominal pressure-increase in SUI and continent women. Twenty-five urodynamically proven SUI women and eight continent volunteer women were assessed by ICIQ-SF, pad-weighing test, incontinence diary, and UPR. UPR was conducted during resting and increased intra-abdominal pressure (P(Abd)) by straining. Related values of P(Abd) and urethral opening pressure (P(o)) were plotted into an abdomino-urethral pressuregram. Linear regression of the values was conducted, and the slope of the line ("APIR") and the intercept with the y-axis found. By the equation of the line, Po was calculated for various values of P(Abd), for example, 50 cm H2O (P(o-Abd 50)). The resting P(o) (P(o-rest)) and APIR, respectively, significantly differed in SUI and continent women but could not separate the two groups. The urethral closure equation (UCE) based on P(o-rest) and APIR provided a more detailed characterization of a woman's closure function based on the permanent closure forces (primarily generated by the urethral sphincteric unit) and the adjunctive closure forces (primarily generated by the support system). P(o-Abd 50) and UCE, respectively, which express the combined permanent and adjunctive closure forces and estimate the efficiency of the closure function, separated SUI and continent women and were highly significantly negatively correlated with ICIQ-SF, pad test, and the number of incontinence episodes. New parameters for characterization of the urethral closure function and possible dysfunctions and its efficiency were provided. P(o-Abd 50) and UCE may be used as diagnostic tests and severity measures. © 2013 Wiley Periodicals, Inc.

  4. Pre/post-closure assessment of groundwater pharmaceutical fate in a wastewater‑facility-impacted stream reach

    USGS Publications Warehouse

    Bradley, Paul M.; Barber, Larry B.; Clark, Jimmy M.; Duris, Joseph W.; Foreman, William T.; Furlong, Edward T.; Givens, Carrie E.; Hubbard, Laura E.; Hutchinson, Kasey J.; Journey, Celeste A.; Keefe, Steffanie H.; Kolpin, Dana W.

    2016-01-01

    Pharmaceutical contamination of contiguous groundwater is a substantial concern in wastewater-impacted streams, due to ubiquity in effluent, high aqueous mobility, designed bioactivity, and to effluent-driven hydraulic gradients. Wastewater treatment facility (WWTF) closures are rare environmental remediation events; offering unique insights into contaminant persistence, long-term wastewater impacts, and ecosystem recovery processes. The USGS conducted a combined pre/post-closure groundwater assessment adjacent to an effluent-impacted reach of Fourmile Creek, Ankeny, Iowa, USA. Higher surface-water concentrations, consistent surface-water to groundwater concentration gradients, and sustained groundwater detections tens of meters from the stream bank demonstrated the importance of WWTF effluent as the source of groundwater pharmaceuticals as well as the persistence of these contaminants under effluent-driven, pre-closure conditions. The number of analytes (110 total) detected in surface water decreased from 69 prior to closure down to 8 in the first post-closure sampling event approximately 30 d later, with a corresponding 2 order of magnitude decrease in the cumulative concentration of detected analytes. Post-closure cumulative concentrations of detected analytes were approximately 5 times higher in proximal groundwater than in surface water. About 40% of the 21 contaminants detected in a downstream groundwater transect immediately before WWTF closure exhibited rapid attenuation with estimated half-lives on the order of a few days; however, a comparable number exhibited no consistent attenuation during the year-long post-closure assessment. The results demonstrate the potential for effluent-impacted shallow groundwater systems to accumulate pharmaceutical contaminants and serve as long-term residual sources, further increasing the risk of adverse ecological effects in groundwater and the near-stream ecosystem.

  5. The Effect on Somatic Growth of Surgical and Catheter Treatment of Secundum Atrial Septal Defects.

    PubMed

    Chlebowski, Meghan M; Dai, Hongying; Kaine, Stephen F

    2017-10-01

    Historical studies suggest an association between atrial septal defect (ASD) and impaired growth with inconsistent improvement following closure. Limited data exist regarding the impact on growth in the era of transcatheter therapy. To evaluate the effect of closure on growth, we conducted a retrospective review of patients undergoing surgical or transcatheter closure during two time periods. Four hundred patients with isolated secundum ASD were divided into three cohorts: early surgical, contemporary surgical, and transcatheter. Data collected included demographics; height, weight, and body mass index (BMI) percentiles; catheterization hemodynamics; and co-morbidities. For all cohorts, there was no significant change in height or weight percentiles during two years after ASD closure. Age at repair was later for contemporary surgical and transcatheter cohorts (p < 0.0001). In the transcatheter cohort, mean Qp:Qs was 1.65 ± 0.54, but there was no correlation between greater Qp:Qs and decreased somatic growth. Subgroup analysis for patients with any initial growth percentile <5th percentile demonstrated a significant change in weight and BMI percentiles in the first two years after closure (p < 0.0004). The advent of transcatheter therapy shifted institutional practice to later age at repair for both surgical and transcatheter closure. There was no significant change in weight and height percentiles during two years after closure. Only patients with initial weight and BMI <5th percentile had improved growth after treatment. Concern for impaired growth should not generally be an indication for early ASD repair. However, early repair may be indicated in children with existing significant growth failure.

  6. A field evaluation of the Eye-Closure Interview with witnesses of serious crimes.

    PubMed

    Vredeveldt, Annelies; Tredoux, Colin G; Nortje, Alicia; Kempen, Kate; Puljević, Cheneal; Labuschagne, Gérard N

    2015-04-01

    Laboratory research shows that eye-closure during memory retrieval improves both the amount and the factual accuracy of memory reports about witnessed events. Based on these findings, we developed the Eye-Closure Interview, and examined its feasibility (in terms of compliance with the instructions) and effectiveness (in terms of the quantity and quality of reported information) in eyewitness interviews conducted by the South African Police Service. Police interviewers from the Facial Identification Unit were randomly assigned to receive Eye-Closure Interview training or no training. We analyzed 95 interviews with witnesses of serious crimes (including robbery, rape, and murder), some of whom were instructed to close their eyes during salient parts of the interview. Witnesses in the control condition rarely spontaneously closed their eyes, but witnesses in the Eye-Closure Interview condition kept their eyes closed during 97% of their descriptions, suggesting that the Eye-Closure Interview would be easy to implement in a field setting. Although witnesses who closed their eyes did not remember more information overall, the information they provided was considered to be of significantly greater forensic relevance (as reflected in 2 independent blind assessments, 1 by a senior police expert and 1 by a senior researcher). Thus, based on the findings from this field study and from previous laboratory research, we conclude that implementation of the Eye-Closure Interview in witness interviews would help police interviewers to elicit more valuable information from witnesses, which could be relevant to the police investigation and/or in court. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  7. Risk factors of stoma re-creation after closure of diverting ileostomy in patients with rectal cancer who underwent low anterior resection or intersphincteric resection with loop ileostomy.

    PubMed

    Song, Ook; Kim, Kyung Hwan; Lee, Soo Young; Kim, Chang Hyun; Kim, Young Jin; Kim, Hyeong Rok

    2018-04-01

    The aim of this study was to identify the risk factors of stoma re-creation after closure of diverting ileostomy in patients with rectal cancer who underwent low anterior resection (LAR) or intersphincteric resection (ISR) with loop ileostomy. We retrospectively reviewed 520 consecutive patients with rectal cancer who underwent LAR or ISR with loop ileostomy from January 2005 to December 2014 at Chonnam National University Hwasun Hospital. Risk factors for stoma re-creation after ileostomy closure were evaluated. Among 520 patients with rectal cancer who underwent LAR or ISR with loop ileostomy, 458 patients underwent stoma closure. Among these patients, 45 (9.8%) underwent stoma re-creation. The median period between primary surgery and stoma closure was 5.5 months (range, 0.5-78.3 months), and the median period between closure and re-creation was 6.8 months (range, 0-71.5 months). Stoma re-creation was performed because of anastomosis-related complications (26, 57.8%), local recurrence (15, 33.3%), and anal sphincter dysfunction (3, 6.7%). Multivariate analysis showed that independent risk factors for stoma re-creation were anastomotic leakage (odds ratio [OR], 4.258; 95% confidence interval [CI], 1.814-9.993), postoperative radiotherapy (OR, 3.947; 95% CI, 1.624-9.594), and ISR (OR, 3.293; 95% CI, 1.462-7.417). Anastomotic leakage, postoperative radiotherapy, and ISR were independent risk factors for stoma re-creation after closure of ileostomy in patients with rectal cancer.

  8. Transcatheter closure of patent ductus arteriosus: 11 years of clinical experience in Cipto Mangunkusumo Hospital, Jakarta, Indonesia.

    PubMed

    Djer, Mulyadi M; Saputro, Dimas Dwi; Putra, Sukman Tulus; Idris, Nikmah Salamia

    2015-06-01

    Transcatheter closure of patent ductus arteriosus (PDA) has been suggested to be the standard treatment of PDA. Although, in general, the procedure shows a high successful rate, outcomes may vary among pediatric cardiology centers. To evaluate the effectiveness of transcatheter closure of PDA in Cipto Mangunkusumo Hospital, Jakarta, Indonesia, this was a retrospective study on patients who underwent transcatheter closure of PDA in Cipto Mangunkusumo Hospital during the period of 2002-2013. Hospital registry was reviewed and data about patients' characteristics, PDA severity, procedure, and outcomes were retrieved. There were 298 patients, of whom 90 were males, who underwent transcatheter closure of PDA during the study period. Median age was 3.4 years (1 months-18 years), and median body weight was 12 (3.6-59) kg. The diameter of PDA ranged from 1.1 to 15.4 mm with a median of 3.7 mm. Device could be deployed in all patients, in which most were the Amplatzer ductal occluder (69.8 %) and the remainders were coils. Median fluoroscopy time was 15.4 (1.5-87) min, and procedure time was 76 (30-200) min. Complete closure was achieved in most patients (97.3 %), whereas device migration occurred in a minority (0.3 %) of patients. No major complication occurred during or after the procedure. Transient anemia and bradycardia were found in 3.7 and 1.3 % patients, respectively. Most patients were discharged from the hospital at 1 day after the procedure. Transcatheter closure method is a safe and effective procedure to close PDA.

  9. Thermic sealing in femoral catheterisation: First experience with the Secure Device.

    PubMed

    Sacherer, Michael; Kolesnik, Ewald; von Lewinski, Friederike; Verheyen, Nicolas; Brandner, Karin; Wallner, Markus; Eaton, Deborah M; Luha, Olev; Zweiker, Robert; von Lewinski, Dirk

    2018-04-03

    Devices currently used to achieve hemostasis of the femoral artery following percutaneous cardiac catheterization are associated with vascular complications and remnants of artificial materials are retained at the puncture site. The SECURE arterial closure device induces hemostasis by utilizing thermal energy, which causes collagen shrinking and swelling. In comparison to established devices, it has the advantage of leaving no foreign material in the body following closing. This study was designed to evaluate the efficacy and safety of the SECURE device to close the puncture site following percutaneous cardiac catheterization. The SECURE device was evaluated in a prospective non-randomized single-centre trial with patients undergoing 6 F invasive cardiac procedures. A total of 67 patients were enrolled and the device was utilized in 63 patients. 50 diagnostic and 13 interventional cases were evaluated. Femoral artery puncture closure was performed immediately after completion of the procedure. Time to hemostasis (TTH), time to ambulation (TTA) and data regarding short-term and 30-day clinical follow-up were recorded. Mean TTH was 4:30 ± 2:15 min in the overall observational group. A subpopulation of patients receiving anticoagulants had a TTH of 4:53 ± 1:43 min. There were two access site complications (hematoma > 5 cm). No major adverse events were identified during hospitalization or at the 30 day follow-up. The new SECURE device demonstrates that it is feasible in diagnostic and interventional cardiac catheterization. With respect to safety, the SECURE device was non-inferior to other closure devices as tested in the ISAR closure trial.

  10. Community-based evaluation of laparoscopic versus open simple closure of perforated peptic ulcers.

    PubMed

    Kuwabara, Kazuaki; Matsuda, Shinya; Fushimi, Kiyohide; Ishikawa, Koichi B; Horiguchi, Hiromasa; Fujimori, Kenji

    2011-11-01

    Several studies have advocated laparoscopic simple closure (LSC) as the treatment of choice for perforated peptic ulcer disease (PUD). However, there has been no comprehensive community-based evaluation of the advantages of using LSC over open simple closure (OSC). Using an administrative database, we evaluated LSC versus OSC for patients with perforated ulcers. From 6,334 patients with perforated ulcers, we identified 2,909 simple closure cases between 2006 and 2010. Study variables were demographics, mortality, co-morbidities, complications, ulcer location, surgical timing, blood transfusion, postoperative ventilation, operating room (OR) time, time to resumption of oral food intake, length of stay (LOS), and total charges. After matching patient baseline variables between OSC and LSC, we performed multivariate analyses to assess the impacts of LSC on mortality, complications, and ventilation administration. A total of 2,073 OSC cases and 836 LSC cases were identified in 670 hospitals. Younger age, duodenal ulcer, and pre-existing PUD were indicators for selection of LSC. Matching analysis indicated a correlation between LSC and lower mortality, less frequent postoperative and overall blood transfusion, shorter LOS, earlier return to oral intake, and longer OR time. There was no difference between OSC and LSC in complication rate or mortality. Longer OR time was correlated with a higher complication rate and the need for ventilation, the latter of which was independently associated with an increase in mortality. Because longer OR time was associated with more frequent complications and ventilation, surgeons should obtain the skills and strategies necessary to accomplish LSC without extending OR time improperly.

  11. Cortical Spreading Depression Closes Paravascular Space and Impairs Glymphatic Flow: Implications for Migraine Headache

    PubMed Central

    Melo-Carrillo, Agustin; Strassman, Andrew M.

    2017-01-01

    Functioning of the glymphatic system, a network of paravascular tunnels through which cortical interstitial solutes are cleared from the brain, has recently been linked to sleep and traumatic brain injury, both of which can affect the progression of migraine. This led us to investigate the connection between migraine and the glymphatic system. Taking advantage of a novel in vivo method we developed using two-photon microscopy to visualize the paravascular space (PVS) in naive uninjected mice, we show that a single wave of cortical spreading depression (CSD), an animal model of migraine aura, induces a rapid and nearly complete closure of the PVS around surface as well as penetrating cortical arteries and veins lasting several minutes, and gradually recovering over 30 min. A temporal mismatch between the constriction or dilation of the blood vessel lumen and the closure of the PVS suggests that this closure is not likely to result from changes in vessel diameter. We also show that CSD impairs glymphatic flow, as indicated by the reduced rate at which intraparenchymally injected dye was cleared from the cortex to the PVS. This is the first observation of a PVS closure in connection with an abnormal cortical event that underlies a neurological disorder. More specifically, the findings demonstrate a link between the glymphatic system and migraine, and suggest a novel mechanism for regulation of glymphatic flow. SIGNIFICANCE STATEMENT Impairment of brain solute clearance through the recently described glymphatic system has been linked with traumatic brain injury, prolonged wakefulness, and aging. This paper shows that cortical spreading depression, the neural correlate of migraine aura, closes the paravascular space and impairs glymphatic flow. This closure holds the potential to define a novel mechanism for regulation of glymphatic flow. It also implicates the glymphatic system in the altered cortical and endothelial functioning of the migraine brain. PMID:28193695

  12. Cortical Spreading Depression Closes Paravascular Space and Impairs Glymphatic Flow: Implications for Migraine Headache.

    PubMed

    Schain, Aaron J; Melo-Carrillo, Agustin; Strassman, Andrew M; Burstein, Rami

    2017-03-15

    Functioning of the glymphatic system, a network of paravascular tunnels through which cortical interstitial solutes are cleared from the brain, has recently been linked to sleep and traumatic brain injury, both of which can affect the progression of migraine. This led us to investigate the connection between migraine and the glymphatic system. Taking advantage of a novel in vivo method we developed using two-photon microscopy to visualize the paravascular space (PVS) in naive uninjected mice, we show that a single wave of cortical spreading depression (CSD), an animal model of migraine aura, induces a rapid and nearly complete closure of the PVS around surface as well as penetrating cortical arteries and veins lasting several minutes, and gradually recovering over 30 min. A temporal mismatch between the constriction or dilation of the blood vessel lumen and the closure of the PVS suggests that this closure is not likely to result from changes in vessel diameter. We also show that CSD impairs glymphatic flow, as indicated by the reduced rate at which intraparenchymally injected dye was cleared from the cortex to the PVS. This is the first observation of a PVS closure in connection with an abnormal cortical event that underlies a neurological disorder. More specifically, the findings demonstrate a link between the glymphatic system and migraine, and suggest a novel mechanism for regulation of glymphatic flow. SIGNIFICANCE STATEMENT Impairment of brain solute clearance through the recently described glymphatic system has been linked with traumatic brain injury, prolonged wakefulness, and aging. This paper shows that cortical spreading depression, the neural correlate of migraine aura, closes the paravascular space and impairs glymphatic flow. This closure holds the potential to define a novel mechanism for regulation of glymphatic flow. It also implicates the glymphatic system in the altered cortical and endothelial functioning of the migraine brain. Copyright © 2017 the authors 0270-6474/17/372904-12$15.00/0.

  13. Prehospital Indicators for Disaster Preparedness and Response: New York City Emergency Medical Services in Hurricane Sandy.

    PubMed

    Smith, Silas W; Braun, James; Portelli, Ian; Malik, Sidrah; Asaeda, Glenn; Lancet, Elizabeth; Wang, Binhuan; Hu, Ming; Lee, David C; Prezant, David J; Goldfrank, Lewis R

    2016-06-01

    We aimed to evaluate emergency medical services (EMS) data as disaster metrics and to assess stress in surrounding hospitals and a municipal network after the closure of Bellevue Hospital during Hurricane Sandy in 2012. We retrospectively reviewed EMS activity and call types within New York City's 911 computer-assisted dispatch database from January 1, 2011, to December 31, 2013. We evaluated EMS ambulance transports to individual hospitals during Bellevue's closure and incremental recovery from urgent care capacity, to freestanding emergency department (ED) capability, freestanding ED with 911-receiving designation, and return of inpatient services. A total of 2,877,087 patient transports were available for analysis; a total of 707,593 involved Manhattan hospitals. The 911 ambulance transports disproportionately increased at the 3 closest hospitals by 63.6%, 60.7%, and 37.2%. When Bellevue closed, transports to specific hospitals increased by 45% or more for the following call types: blunt traumatic injury, drugs and alcohol, cardiac conditions, difficulty breathing, "pedestrian struck," unconsciousness, altered mental status, and emotionally disturbed persons. EMS data identified hospitals with disproportionately increased patient loads after Hurricane Sandy. Loss of Bellevue, a public, safety net medical center, produced statistically significant increases in specific types of medical and trauma transports at surrounding hospitals. Focused redeployment of human, economic, and social capital across hospital systems may be required to expedite regional health care systems recovery. (Disaster Med Public Health Preparedness. 2016;10:333-343).

  14. F-Tank Farm Performance Assessment Updates through the Special Analysis Process at Savannah River Site - 12169

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Layton, Mark H.

    2012-07-01

    The F-Area Tank Farm (FTF) is owned by the U.S. Department of Energy and operated by Savannah River Remediation, LLC (SRR), Liquid Waste Operations contractor at DOE's Savannah River Site (SRS). The FTF is in the north-central portion of the SRS and occupies approximately 22 acres within F-Area. The FTF is an active radioactive waste storage facility consisting of 22 carbon steel waste tanks and ancillary equipment such as transfer lines, evaporators and pump tanks. An FTF Performance Assessment (PA) was prepared to support the eventual closure of the FTF underground radioactive waste tanks and ancillary equipment. The PA providesmore » the technical basis and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements identified below for final closure of FTF. The FTank Farm is subject to a state industrial waste water permit and Federal Facility Agreement. Closure documentation will include an F-Tank Farm Closure Plan and tank-specific closure modules utilizing information from the performance assessment. For this reason, the State of South Carolina and the Environmental Protection Agency must be involved in the performance assessment review process. The residual material remaining after tank cleaning is also subject to reclassification prior to closure via a waste determination pursuant to Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005. The projected waste tank inventories in the FTF PA provide reasonably bounding FTF inventory projections while taking into account uncertainties in the effectiveness of future tank cleaning technologies. As waste is removed from the FTF waste tanks, the residual contaminants will be sampled and the remaining residual inventory is characterized. In this manner, tank specific data for the tank inventories at closure will be available to supplement the waste tank inventory projections currently used in the FTF PA. For FTF, the new tank specific data will be evaluated through the Special Analysis process. The FTF Special Analyses process will be utilized to evaluate information regarding the final residual waste that will be grouted in place in the FTF Tanks and assess the potential impact the new inventory information has on the FTF PA assumptions and results. The Special Analysis can then be used to inform decisions regarding FTF tank closure documents. The purpose of this paper is to discuss the Special Analysis process and share insights gained while implementing this process. An example of an area of interest in the revision process is balancing continuous improvement versus configuration control of agreed upon methodologies. Other subjects to be covered include: 1) defining the scope of the revisions included in the Special Analysis, 2) determining which PA results should be addressed in the Special Analysis, and 3) deciding whether the Special Analysis should utilize more qualitative or quantitative assessments. For the SRS FTF, an FTF PA has been prepared to provide the technical basis and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements for final closure of FTF. The FTF Special Analyses process will be utilized to evaluate the impact new information has on the FTF PA assumptions and results. The Special Analysis can then be used to inform decisions regarding FTF tank closure documents. In preparing SAs, it is crucial that the scope of the SA be well defined within the SA, since the specific scope will vary from SA to SA. Since the SAs are essentially addendums to the PA, the SA scope should utilize the PA as the baseline from which the SA scope is defined. The SA needs to focus on evaluating the change associated with the scope, and not let other changes interfere with the ability to perform that evaluation by masking the impact of the change. In preparing the SA, it is also important to let the scope determine whether the Special Analysis should utilize more qualitative or quantitative assessments and also which results from the PA should be addressed in the Special Analysis. These decisions can vary from SA and should not be predetermined. (author)« less

  15. Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.

    PubMed

    Nolan, Winifred P; See, Jovina L; Chew, Paul T K; Friedman, David S; Smith, Scott D; Radhakrishnan, Sunita; Zheng, Ce; Foster, Paul J; Aung, Tin

    2007-01-01

    To evaluate noncontact anterior segment optical coherence technology (AS-OCT) as a qualitative method of imaging the anterior chamber angle and to determine its ability to detect primary angle closure when compared with gonioscopy in Asian subjects. Prospective observational case series. Two hundred three subjects were recruited from glaucoma clinics in Singapore with diagnoses of primary angle closure, primary open-angle glaucoma, ocular hypertension, or cataract. Both eyes (if eligible) of each patient were included in the study. Exclusion criteria were pseudophakia or previous glaucoma surgery. Images of the nasal, temporal, and inferior angles were obtained with AS-OCT in dark and then light conditions. Gonioscopic angle width was graded using the Spaeth classification for each quadrant in low lighting conditions. Angle closure was defined by AS-OCT as contact between the peripheral iris and angle wall anterior to the scleral spur and by gonioscopy as a Spaeth grade of 0 degree (posterior trabecular meshwork not visible). Comparison of the 2 methods in detecting angle closure was done by eye and by individual. Sensitivities and specificities of AS-OCT were calculated using gonioscopy as the reference standard. Complete data were available for 342 eyes of 200 patients. Of the patients, 70.9% had a clinical diagnosis of treated or untreated primary angle closure. Angle closure in > or =1 quadrants was detected by AS-OCT in 142 (71%) patients (228 [66.7%] eyes) and by gonioscopy in 99 (49.5%) patients (152 [44.4%] eyes). The inferior angle was closed more frequently than the nasal or temporal quadrants using both AS-OCT and gonioscopy. When performed under dark conditions, AS-OCT identified 98% of those subjects found to have angle closure on gonioscopy (95% confidence interval [CI], 92.2-99.6) and led to the characterization of 44.6% of those found to have open angles on gonioscopy to have angle closure as well. With gonioscopy as the reference standard, specificity of AS-OCT in the dark was 55.4% (95% CI, 45.2-65.2) for detecting individuals with angle closure. Anterior segment OCT is a rapid noncontact method of imaging angle structures. It is highly sensitive in detecting angle closure when compared with gonioscopy. More persons are found to have closed angles with AS-OCT than with gonioscopy.

  16. Closure properties of Watson-Crick grammars

    NASA Astrophysics Data System (ADS)

    Zulkufli, Nurul Liyana binti Mohamad; Turaev, Sherzod; Tamrin, Mohd Izzuddin Mohd; Azeddine, Messikh

    2015-12-01

    In this paper, we define Watson-Crick context-free grammars, as an extension of Watson-Crick regular grammars and Watson-Crick linear grammars with context-free grammar rules. We show the relation of Watson-Crick (regular and linear) grammars to the sticker systems, and study some of the important closure properties of the Watson-Crick grammars. We establish that the Watson-Crick regular grammars are closed under almost all of the main closure operations, while the differences between other Watson-Crick grammars with their corresponding Chomsky grammars depend on the computational power of the Watson-Crick grammars which still need to be studied.

  17. Beyond NIMBYs and NOOMBYs: what can wind farm controversies teach us about public involvement in hospital closures?

    PubMed

    Stewart, Ellen; Aitken, Mhairi

    2015-12-01

    Many policymakers, researchers and commentators argue that hospital closures are necessary as health systems adapt to new technological and financial contexts, and as population health needs in developed countries shift. However closures are often unpopular with local communities. Previous research has characterised public opposition as an obstacle to change. Public opposition to the siting of wind farms, often described as NIMBYism (Not In My Back Yard), is a useful comparator issue to the perceived NOOMBYism (Not Out Of My Back Yard) of hospital closure protestors. The analysis of public attitudes to wind farms has moved from a fairly crude characterisation of the 'attitude-behaviour gap' between publics who support the idea of wind energy, but oppose local wind farms, to empirical, often qualitative, studies of public perspectives. These have emphasised the complexity of public attitudes, and revealed some of the 'rational' concerns which lie beneath protests. Research has also explored processes of community engagement within the wind farm decision-making process, and the crucial role of trust between communities, authorities, and developers. Drawing on what has been learnt from studies of opposition to wind farms, we suggest a range of questions and approaches to explore public perspectives on hospital closure more thoroughly. Understanding the range of public responses to service change is an important first step in resolving the practical dilemma of effecting health system transformation in a democratic fashion.

  18. [Stapler and manual bronchial anastomosis--results of a consecutive trial series].

    PubMed

    Junginger, T; Walgenbach, S; Pichlmaier, H

    1989-01-01

    After lobectomy and pneumonectomy in experimental evaluations stapled bronchial closures showed the lowest incidence of inflammatory reaction and the highest strength determined by leakage pressure compared with other suture material. A total of 233 lung resections-performed at Surgical University Clinic Köln-Lindenthal and the Clinic for General and Abdominal Surgery of the Johannes-Gutenberg-Universität Mainz--were reviewed. Mechanical stapling reduced the rate of bronchopleural fistulas to 2.0% compared with 7.1% after manual suturing. In parallel, mortality related to bronchial stump leakage decreased to 0.7%. Main advantages of bronchial closure with staplers are the simplicity of their use, the speed and the uniformity of the closure. Thereby stapling devices are valuable completions in pulmonary surgery.

  19. Interventional Closure of a Patent Ductus Arteriosus Using an Amplatz Canine Duct Occluder in an Alpaca Cria.

    PubMed

    Chapel, E C; Lozier, J; Lakritz, J; Schober, K E

    2017-07-01

    A 6-month old female alpaca cria presented to The Ohio State University for evaluation of a cardiac murmur. Echocardiography revealed a left-to-right shunting patent ductus arteriosus, a restrictive left-to-right shunting perimembranous ventricular septal defect, and secondary moderate left atrial and ventricular dilation. Aortic root angiography demonstrated a type IIA patent ductus arteriosus (PDA). Interventional closure of the PDA was successfully performed, without complication, using an Amplatz canine duct occluder. This case report describes the materials and methods used for interventional closure of a PDA in an alpaca cria. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  20. The macroeconomic impact of pandemic influenza: estimates from models of the United Kingdom, France, Belgium and The Netherlands.

    PubMed

    Keogh-Brown, Marcus Richard; Smith, Richard D; Edmunds, John W; Beutels, Philippe

    2010-12-01

    The 2003 outbreak of severe acute respiratory syndrome (SARS) showed that infectious disease outbreaks can have notable macroeconomic impacts. The current H1N1 and potential H5N1 flu pandemics could have a much greater impact. Using a multi-sector single country computable general equilibrium model of the United Kingdom, France, Belgium and The Netherlands, together with disease scenarios of varying severity, we examine the potential economic cost of a modern pandemic. Policies of school closure, vaccination and antivirals, together with prophylactic absence from work are evaluated and their cost impacts are estimated. Results suggest GDP losses from the disease of approximately 0.5-2% but school closure and prophylactic absenteeism more than triples these effects. Increasing school closures from 4 weeks at the peak to entire pandemic closure almost doubles the economic cost, but antivirals and vaccinations seem worthwhile. Careful planning is therefore important to ensure expensive policies to mitigate the pandemic are effective in minimising illness and deaths.

Top