Sample records for closure performance standards

  1. 40 CFR 264.111 - Closure performance standard.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 264.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES... eliminates, to the extent necessary to protect human health and the environment, post-closure escape of...

  2. 40 CFR 264.111 - Closure performance standard.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Section 264.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES... eliminates, to the extent necessary to protect human health and the environment, post-closure escape of...

  3. 40 CFR 264.111 - Closure performance standard.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... eliminates, to the extent necessary to protect human health and the environment, post-closure escape of hazardous waste, hazardous constituents, leachate, contaminated run-off, or hazardous waste decomposition...

  4. 40 CFR 265.111 - Closure performance standard.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Controls, minimizes or eliminates, to the extent necessary to protect human health and the environment, post-closure escape of hazardous waste, hazardous constituents, leachate, contaminated run-off, or...

  5. 40 CFR 264.120 - Certification of completion of post-closure care.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... certification that the post-closure care period for the hazardous waste disposal unit was performed in...) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... later than 60 days after completion of the established post-closure care period for each hazardous waste...

  6. Hanford Facility Dangerous Waste Closure Plan - Plutonium Finishing Plant Treatment Unit Glovebox HA-20MB

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PRIGNANO, A.L.

    2003-06-25

    This closure plan describes the planned activities and performance standards for closing the Plutonium Finishing Plant (PFP) glovebox HA-20MB that housed an interim status ''Resource Conservation and Recovery Act'' (RCRA) of 1976 treatment unit. This closure plan is certified and submitted to Ecology for incorporation into the Hanford Facility RCRA Permit (HF RCRA Permit) in accordance with Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement; TPA) Milestone M-83-30 requiring submittal of a certified closure plan for ''glovebox HA-20MB'' by July 31, 2003. Glovebox HA-20MB is located within the 231-5Z Building in the 200 West Area of the Hanford Facility.more » Currently glovebox HA-20MB is being used for non-RCRA analytical purposes. The schedule of closure activities under this plan supports completion of TPA Milestone M-83-44 to deactivate and prepare for dismantlement the above grade portions of the 234-5Z and ZA, 243-Z, and 291-Z and 291-Z-1 stack buildings by September 30, 2015. Under this closure plan, glovebox HA-20MB will undergo clean closure to the performance standards of Washington Administrative Code (WAC) 173-303-610 with respect to all dangerous waste contamination from glovebox HA-20MB RCRA operations. Because the intention is to clean close the PFP treatment unit, postclosure activities are not applicable to this closure plan. To clean close the unit, it will be demonstrated that dangerous waste has not been left at levels above the closure performance standard for removal and decontamination. If it is determined that clean closure is not possible or is environmentally impractical, the closure plan will be modified to address required postclosure activities. Because dangerous waste does not include source, special nuclear, and by-product material components of mixed waste, radionuclides are not within the scope of this documentation. Any information on radionuclides is provided only for general knowledge. Clearance form only sent to RHA.« less

  7. Development of uniform standards for allowable lane closure : final report, September 2008.

    DOT National Transportation Integrated Search

    2008-09-01

    Procedures for determining allowable lane closure hours to perform maintenance, construction, resurfacing, regional permit and major access permit work on the state highway system were evaluated. The current process involves the collection of traffic...

  8. 40 CFR 265.112 - Closure plan; amendment of plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... residues and contaminated containment system components, equipment, structures, and soils during partial... contaminated soils, methods for sampling and testing surrounding soils, and criteria for determining the extent of decontamination necessary to satisfy the closure performance standard; and (5) A detailed...

  9. 40 CFR 264.112 - Closure plan; amendment of plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... residues and contaminated containment system components, equipment, structures, and soils during partial... contaminated soils, methods for sampling and testing surrounding soils, and criteria for determining the extent of decontamination required to satisfy the closure performance standard; and (5) A detailed...

  10. Assessment of circumferential angle-closure by the iris-trabecular contact index with swept-source optical coherence tomography.

    PubMed

    Baskaran, Mani; Ho, Sue-Wei; Tun, Tin A; How, Alicia C; Perera, Shamira A; Friedman, David S; Aung, Tin

    2013-11-01

    To evaluate the diagnostic performance of the iris-trabecular contact (ITC) index, a measure of the degree of angle-closure, using swept-source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan) in comparison with gonioscopy. Prospective observational study. A total of 108 normal subjects and 32 subjects with angle-closure. The SSOCT 3-dimensional angle scans, which obtain radial scans for the entire circumference of the angle, were performed under dark conditions and analyzed using customized software by a single examiner masked to the subjects' clinical details. The ITC index was calculated as a percentage of the angle that was closed on SSOCT images. First-order agreement coefficient (AC1) statistics and area under the receiver operating characteristic curve (AUC) analyses were performed for angle-closure on the basis of the ITC index in comparison with gonioscopy. Angle-closure on gonioscopy was defined as nonvisibility of posterior trabecular meshwork for at least 2 quadrants. Agreement of the ITC index with gonioscopically defined angle-closure was assessed using the AC1 statistic. Study subjects were predominantly Chinese (95.7%) and female (70.7%), with a mean age of 59.2 (standard deviation, 8.9) years. The median ITC index was 15.24% for gonioscopically open-angle eyes (n = 108) and 48.5% for closed-angle eyes (n = 32) (P = 0.0001). The agreement for angle-closure based on ITC index cutoffs (>35% and ≥50%) and gonioscopic angle-closure was 0.699 and 0.718, respectively. The AUC for angle-closure detection using the ITC index was 0.83 (95% confidence interval, 0.76-0.89), with an ITC index >35% having a sensitivity of 71.9% and specificity of 84.3%. The ITC index is a summary measure of the circumferential extent of angle-closure as imaged with SSOCT. The index had moderate agreement and good diagnostic performance for angle-closure with gonioscopy as the reference standard. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  11. 3718-F Alkali Metal Treatment and Storage Facility Closure Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Since 1987, Westinghouse Hanford Company has been a major contractor to the U.S. Department of Energy-Richland Operations Office and has served as co-operator of the 3718-F Alkali Metal Treatment and Storage Facility, the waste management unit addressed in this closure plan. The closure plan consists of a Part A Dangerous waste Permit Application and a RCRA Closure Plan. An explanation of the Part A Revision (Revision 1) submitted with this document is provided at the beginning of the Part A section. The closure plan consists of 9 chapters and 5 appendices. The chapters cover: introduction; facility description; process information; wastemore » characteristics; groundwater; closure strategy and performance standards; closure activities; postclosure; and references.« less

  12. Repair of Medial Patellofemoral, Ligament Improves Patellar, Tracking in Total Knee Replacement.

    PubMed

    Meneghini, R Michael; Ziemba-Davis, Mary; Smits, Shelly; Bicos, James

    2015-11-01

    The medial patellofemoral ligament (MPFL) is essential to maintain patella stability; however, its role in total knee replacement (TKR) has not been studied. Forty-six consecutive TKRs in 40 patients were reviewed. Standard closure was performed in 29 TKRs. The MPFL was isolated and anatomically re-approximated in 17 subsequent TKRs. Blinded radiographic evaluation of patellar tilt and subluxation was performed preoperatively and 4 months postoperatively. Despite greater preoperative lateral tilt, the MPFL repair group demonstrated greater correction in patellar tilt compared with the standard closure group (p = 0.02). Patellar tracking also was optimized in the MPFL group, despite equivalent preoperative lateral patellar subluxation in the two groups. Simple repair of the MPFL at arthrotomy closure appears to optimize patellar stability radiographically and may improve long-term results by minimizing patellar complications and wear.

  13. Impact of Different Standard Type A7A Drum Closure-Ring Practices on Gasket Contraction and Bolt Closure Distance– 15621

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ketusky, Edward; Blanton, Paul; Bobbitt, John H.

    The Department of Energy, the Savannah River National Laboratory, several manufacturers of specification drums, and the United States Department of Transportation (DOT) are collaborating in the development of a guidance document for DOE contractors and vendors who wish to qualify containers to DOT 7A Type A requirements. Currently, the effort is focused on DOT 7A Type A 208-liter (55-gallons) drums with a standard 12-gauge bolted closure ring. The U.S. requirements, contained in Title 49, Part 178.350 “Specification 7A; general packaging, Type A specifies a competent authority review of the packaging is not required for the transport of (Class 7) radioactivemore » material containing less than Type A quantities of radioactive material. For Type AF drums, a 4 ft. regulatory free drop must be performed, such that the drum “suffers maximum damage.” Although the actual orientation is not defined by the specification, recent studies suggest that maximum damage would result from a shallow angle top impact, where kinetic energy is transferred to the lid, ultimately causing heavy damage to the lid, or even worse, causing the lid to come off. Since each vendor develops closure recommendations/procedures for the drums they manufacture, key parameters applied to drums during closing vary based on vendor. As part of the initial phase of the collaboration, the impact of the closure variants on the ability of the drum to suffer maximum damage is investigated. Specifically, closure testing is performed varying: 1) the amount of torque applied to the closure ring bolt; and, 2) stress relief protocol, including: a) weight of hammer; and, b) orientation that the hammer hits the closure ring. After closure, the amount of drum lid gasket contraction and the distance that the closure bolt moves through the closure ring is measured.« less

  14. Anterior Segment Imaging for Angle Closure.

    PubMed

    Chansangpetch, Sunee; Rojanapongpun, Prin; Lin, Shan C

    2018-04-01

    To summarize the role of anterior segment imaging (AS-imaging) in angle closure diagnosis and management, and the possible advantages over the current standard of gonioscopy. Literature review and perspective. Review of the pertinent publications with interpretation and perspective in relation to the use of AS-imaging in angle closure assessment focusing on anterior segment optical coherence tomography and ultrasound biomicroscopy. Several limitations have been encountered with the reference standard of gonioscopy for angle assessment. AS-imaging has been shown to have performance in angle closure detection compared to gonioscopy. Also, imaging has greater reproducibility and serves as better documentation for long-term follow-up than conventional gonioscopy. The qualitative and quantitative information obtained from AS-imaging enables better understanding of the underlying mechanisms of angle closure and provides useful parameters for risk assessment and possible prediction of the response to laser and surgical intervention. The latest technologies-including 3-dimensional imaging-have allowed for the assessment of the angle that simulates the gonioscopic view. These advantages suggest that AS-imaging has a potential to be a reference standard for the diagnosis and monitoring of angle closure disease in the future. Although gonioscopy remains the primary method of angle assessment, AS-imaging has an increasing role in angle closure screening and management. The test should be integrated into clinical practice as an adjunctive tool for angle assessment. It is arguable that AS-imaging should be considered first-line screening for patients at risk for angle closure. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. A comparison of two endoscopic closures: over-the-scope clip (OTSC) versus KING closure (endoloop + clips) in a randomized long-term experimental study.

    PubMed

    Dolezel, R; Ryska, O; Kollar, M; Juhasova, J; Kalvach, J; Ryska, M; Martinek, J

    2016-11-01

    Both over-the-scope clip (OTSC) and KING (endoloop + clips) closures provide reliable and safe full-thickness endoscopic closure. Nevertheless, OTSC clip demonstrated significantly inferior histological healing in the short-term follow-up. To compare OTSC versus KING closure of a perforation with regard to long-term effectiveness and macroscopic and histological quality of healing. We performed a randomized experimental study with 16 mini-pigs (mean weight 43.2 ± 11.2 kg). A standardized perforation was performed on the anterior sigmoid wall. KING closure (n = 8) was attained by approximation of an endoloop fixed to the margins of a perforation with endoclips. OTSC closure (n = 8) was performed by deploying OTSC (OVESCO) over the defect. Pigs underwent a control sigmoidoscopy 8 months after the closure to assess the macroscopic quality of healing. Then, autopsy was performed and the rectosigmoid was sent for histopathological assessment. All closures were completed successfully without air leaks. The duration of closure was similar in both techniques (OTSC 17.8 ± 7.6 min vs. KING 19.6 ± 8.8 min). At autopsy, all KING closures (100 %) were healed with a flat scar without signs of leakage. Microscopically, no inflammatory changes were observed after KING closure. In the OTSC group, microscopic ulcers were present in two pigs (25 %), cryptal abscesses in three pigs (38 %) and significant neutrophil accumulation in all eight pigs (P < 0.01). Giant cell granulomas, dysplasia or abundant scarification was not observed in either group. Both OTSC and KING closures offer a long-term reliable seal of a gastrointestinal perforation without stenosis or fistulas. KING closure provides long-term histologically superior healing.

  16. Closure of oroantral communications using biodegradable polyurethane foam: a feasibility study.

    PubMed

    Visscher, Susan H; van Minnen, Baucke; Bos, Rudolf R M

    2010-02-01

    The aim of this study was to assess the feasibility of biodegradable polyurethane (PU) foam for closure of oroantral communications (OACs). Ten consecutive patients with OACs (existing <24 hours) were treated with PU foam. Standardized evaluations were performed at 2 weeks and 8 weeks after closure of the OAC. In 5 patients, the OACs were closed successfully without complications. Three patients developed sinusitis, which was conservatively managed with antibiotics in 2 cases. In 1 case the sinus was reopened for irrigation, after which a buccal flap procedure was performed. In 2 patients the OAC recurred and was surgically closed with a buccal flap after thorough irrigation. In this feasibility study, closure was achieved in 7 of the 10 patients without further surgical intervention. Complications of the procedure using PU foam may be related to the fit of the foam in the socket and the size of the perforation. In general, closure of OACs with biodegradable polyurethane foam is feasible and has the potential to spare a large number of patients with OACs a surgical procedure. Furthermore, in case the treatment with PU foam fails to close the OAC, the attending physician can always fall back on the standard surgical procedure. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Comparison of EyeCam and anterior segment optical coherence tomography in detecting angle closure.

    PubMed

    Baskaran, Mani; Aung, Tin; Friedman, David S; Tun, Tin A; Perera, Shamira A

    2012-12-01

    To compare the diagnostic performance of EyeCam (Clarity Medical Systems, Pleasanton, CA, USA) and anterior segment optical coherence tomography (ASOCT, Visante; Carl Zeiss Meditec, Dublin, CA, USA) in detecting angle closure, using gonioscopy as the reference standard. Ninety-eight phakic patients, recruited from a glaucoma clinic, underwent gonioscopy by a single examiner, and EyeCam and ASOCT imaging by another examiner. Another observer, masked to gonioscopy findings, graded EyeCam and ASOCT images. For both gonioscopy and EyeCam, a closed angle in a particular quadrant was defined if the posterior trabecular meshwork was not visible. For ASOCT, angle closure was defined by any contact between the iris and angle anterior to the scleral spur. An eye was diagnosed as having angle closure if ≥2 quadrants were closed. Agreement and area under the receiver operating characteristic curves (AUC) were evaluated. The majority of subjects were Chinese (69/98, 70.4%) with a mean age of 60.6 years. Angle closure was diagnosed in 39/98 (39.8%) eyes with gonioscopy, 40/98 (40.8%) with EyeCam and 56/97 (57.7%) with ASOCT. The agreement (kappa statistic) for angle closure diagnosis for gonioscopy versus EyeCam was 0.89; gonioscopy versus ASOCT and EyeCam versus ASOCT were both 0.56. The AUC for detecting eyes with gonioscopic angle closure with EyeCam was 0.978 (95% CI: 0.93-1.0) and 0.847 (95% CI: 0.76-0.92, p < 0.01) for ASOCT. The diagnostic performance of EyeCam was better than ASOCT in detecting angle closure when gonioscopic grading was used as the reference standard. The agreement between the two imaging modalities was moderate. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  18. A comparison of three algebraic stress closures for combustor flow calculations

    NASA Technical Reports Server (NTRS)

    Nikjooy, M.; So, R. M. C.; Hwang, B. C.

    1985-01-01

    A comparison is made of the performance of two locally nonequilibrium and one equilibrium algebraic stress closures in calculating combustor flows. Effects of four different pressure-strain models on these closure models are also analyzed. The results show that the pressure-strain models have a much greater influence on the calculated mean velocity and turbulence field than the algebraic stress closures, and that the best mean strain model for the pressure-strain terms is that proposed by Launder, Reece and Rodi (1975). However, the equilibrium algebraic stress closure with the Rotta return-to-isotropy model (1951) for the pressure-strain terms gives as good a correlation with measurements as when the Launder et al. mean strain model is included in the pressure-strain model. Finally, comparison of the calculations with the standard k-epsilon closure results show that the algebraic stress closures are better suited for simple turbulent flow calculations.

  19. Cost analysis of negative-pressure wound therapy with instillation for wound bed preparation preceding split-thickness skin grafts for massive (>100 cm(2)) chronic venous leg ulcers.

    PubMed

    Yang, C Kevin; Alcantara, Sean; Goss, Selena; Lantis, John C

    2015-04-01

    Massive (≥100 cm(2)) venous leg ulcers (VLUs) demonstrate very low closure rates with standard compression therapy and are costly to manage. Negative-pressure wound therapy (NPWT), followed by a split-thickness skin graft (STSG), can be a cost-effective alternative to this standard care. We performed a cost analysis of these two treatments. A retrospective review was performed of 10 ulcers treated with surgical debridement, 7 days of inpatient NPWT with topical antiseptic instillation (NPWTi), and STSG, with 4 additional days of inpatient NPWT bolster over the graft. Independent medical cost estimators were used to compare the cost of this treatment protocol with standard outpatient compression therapy. The average length of time ulcers were present before patients entered the study was 38 months (range, 3-120 months). Eight of 10 patients had complete VLU closure by 6 months after NPWTi with STSG. The 6-month costs of the proposed treatment protocol and standard twice-weekly compression therapy were estimated to be $27,000 and $28,000, respectively. NPWTi with STSG treatment is more effective for closure of massive VLUs at 6 months than that reported for standard compression therapy. Further, the cost of the proposed treatment protocol is comparable with standard compression therapy. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  20. Patent Foramen Ovale Closure in the Setting of Cryptogenic Stroke: A Meta-Analysis of Five Randomized Trials.

    PubMed

    Garg, Lohit; Haleem, Affan; Varade, Shweta; Sivakumar, Keithan; Shah, Mahek; Patel, Brijesh; Agarwal, Manyoo; Agrawal, Sahil; Leary, Megan; Kluck, Bryan

    2018-05-24

    The clinical benefit of patent foramen ovale (PFO) closure after cryptogenic stroke has been a topic of debate for decades. Recently, 3 randomized controlled trials of PFO closure in patients with cryptogenic stroke demonstrated a significantly reduced risk of recurrent stroke compared with standard medical therapy alone. This meta-analysis was performed to clarify the efficacy of PFO closure for future stroke prevention in this population. A systematic literature search was undertaken. Published pooled data from 5 large randomized clinical trials (CLOSE, RESPECT, Gore REDUCE, CLOSURE I, and PC) were combined and then subsequently analyzed. Enrolled patients with cryptogenic stroke were assigned to receive standard medical care or to undergo endovascular PFO closure, with a primary outcome of reduction in stroke recurrence rate. Secondary outcomes included rates of transient ischemic attack (TIA), composite outcome of stroke, TIA, and death from all causes, and rates of atrial fibrillation events. We analyzed data for 3412 patients. Transcatheter PFO closure resulted in a statistically significant reduced rate of recurrent stroke, compared with medication alone. Patients undergoing closure were 58% less likely to have another stroke. The number needed to treat with PFO closure to reduce recurrent stroke for 1 patient was 40. Endovascular PFO closure was associated with a reduced risk of recurrent stroke in patients with a prior cryptogenic cerebral infarct. Although the absolute stroke reduction was small, these findings are clinically significant, given the young age of this patient population and the patients' lifetime risk of recurrent stroke. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. Qualitative evaluation of the iris and ciliary body by ultrasound biomicroscopy in subjects with angle closure.

    PubMed

    Ku, Judy Y; Nongpiur, Monisha E; Park, Judy; Narayanaswamy, Arun K; Perera, Shamira A; Tun, Tin A; Kumar, Rajesh S; Baskaran, Mani; Aung, Tin

    2014-12-01

    To qualitatively analyze anterior chamber structures imaged by ultrasound biomicroscopy (UBM) in primary angle-closure patients. Subjects diagnosed as primary angle-closure suspect (PACS), primary angle-closure glaucoma (PACG), and previous acute primary angle closure (APAC) were recruited prospectively along with a group of normal controls. UBM was performed under standardized dark room conditions and qualitative assessment was carried out using a set of reference photographs of standard UBM images to categorize the various anatomic features related to angle configuration. These included overall and basal iris thicknesses, iris convexity, iris angulation, ciliary body size, and ciliary sulcus. A total of 60 PACS, 114 PACG, 41 APAC, and 33 normal controls were included. Patients were predominantly older Chinese females. After controlling the confounding effect of age and sex, eyes with overall thicker irides [medium odds ratio (OR) 3.58, thick OR 2.84] when compared with thin irides have a significantly higher likelihood of having PACS/PACG/APAC versus controls. Thicker basal iris component (medium OR 4.13, thick OR 3.39) also have higher likelihood of having angle closure when compared with thin basal iris thickness. Subjects with basal iris insertion, mild iris angulation, and large ciliary body have a higher OR of having angle closure. In contrast, the presence/absence of a ciliary sulcus did not influence the likelihood of angle closure. Eyes with thicker overall and basal iris thicknesses are more likely to have angle closure than controls. Other features that increase the likelihood of angle closure include basal iris insertion, mild iris angulation, and large ciliary body.

  2. Evaluating Models Of The Neutral, Barotropic Planetary Boundary Layer Using Integral Measures: Part Ii. Modelling Observed Conditions

    NASA Astrophysics Data System (ADS)

    Hess, G. D.; Garratt, J. R.

    The steady-state, horizontally homogeneous, neutral, barotropiccase forms the foundation of our theoretical understanding of the planetary boundary layer (PBL).While simple analytical models and first-order closure models simulate atmospheric observationsof this case well, more sophisticated models, in general, do not. In this paperwe examine how well three higher-order closure models, E - - l, E - l, and LRR - l,which have been especially modified for PBL applications, perform in predicting the behaviour of thecross-isobaric angle 0, the geostrophic drag coefficient Cg, and the integral of the dissipationrate over the boundary layer, as a function of the surface Rossby number Ro. For comparison we alsoexamine the performance of three first-order closure mixing-length models, two proposed byA. K. Blackadar and one by H. H. Lettau, and the performance of the standard model forsecond-order closure and a modification of it designed to reduce the overprediction of turbulence inthe upper part of the boundary layer.

  3. 40 CFR 265.111 - Closure performance standard.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 265.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND...) Controls, minimizes or eliminates, to the extent necessary to protect human health and the environment...

  4. 40 CFR 265.111 - Closure performance standard.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Section 265.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND...) Controls, minimizes or eliminates, to the extent necessary to protect human health and the environment...

  5. Development of a standardized laparoscopic caecum resection model to simulate laparoscopic appendectomy in rats

    PubMed Central

    2014-01-01

    Background Laparoscopic appendectomy (LA) has become one of the most common surgical procedures to date. To improve and standardize this technique further, cost-effective and reliable animal models are needed. Methods In a pilot study, 30 Wistar rats underwent laparoscopic caecum resection (as rats do not have an appendix vermiformis), to optimize the instrumental and surgical parameters. A subsequent test study was performed in another 30 rats to compare three different techniques for caecum resection and bowel closure. Results Bipolar coagulation led to an insufficiency of caecal stump closure in all operated rats (Group 1, n = 10). Endoloop ligation followed by bipolar coagulation and resection (Group 2, n = 10) or resection with a LigaSure™ device (Group 3, n = 10) resulted in sufficient caecal stump closure. Conclusions We developed a LA model enabling us to compare three different caecum resection techniques in rats. In conclusion, only endoloop closure followed by bipolar coagulation proved to be a secure and cost-effective surgical approach. PMID:24934381

  6. [New technology for prevention of embolic events in atrial fibrillation: a systematic review on percutaneous endovascular left atrial appendage closure].

    PubMed

    Danna, Paolo; Sagone, Antonio; Proietti, Riccardo; Arensi, Andrea; Viecca, Maurizio; Santangeli, Pasquale; Di Biase, Luigi; Natale, Andrea

    2012-09-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia. The mortality rate of patients with AF is doubled as compared to non-fibrillating controls. The most relevant complication of AF is a major increase in the risk of stroke. The gold standard in reducing cerebrovascular events in AF is warfarin therapy, which is not free from contraindications and limitations. The left atrial appendage (LAA) is the main source of emboli causing stroke in AF. LAA closure is a seducing approach to stroke risk reduction in AF without anticoagulation. Since 1949, heart surgeons have performed LAA closure or amputation in patients with AF. Percutaneous endovascular LAA closure is a new, less invasive, technique to reach the goal. Several devices have been used to perform this intervention, and the results of published trials are encouraging in terms of effectiveness and relative safety of this attractive technique. In this review we examine the published trials and data on percutaneous LAA closure, with particular attention to the risks and benefits of this procedure.

  7. Dissipative closures for statistical moments, fluid moments, and subgrid scales in plasma turbulence

    NASA Astrophysics Data System (ADS)

    Smith, Stephen Andrew

    1997-11-01

    Closures are necessary in the study physical systems with large numbers of degrees of freedom when it is only possible to compute a small number of modes. The modes that are to be computed, the resolved modes, are coupled to unresolved modes that must be estimated. This thesis focuses on dissipative closures models for two problems that arises in the study of plasma turbulence: the fluid moment closure problem and the subgrid scale closure problem. The fluid moment closures of Hammett and Perkins (1990) were originally applied to a one-dimensional kinetic equation, the Vlasov equation. These closures are generalized in this thesis and applied to the stochastic oscillator problem, a standard paradigm problem for statistical closures. The linear theory of the Hammett- Perkins closures is shown to converge with increasing numbers of moments. A novel parameterized hyperviscosity is proposed for two- dimensional drift-wave turbulence. The magnitude and exponent of the hyperviscosity are expressed as functions of the large scale advection velocity. Traditionally hyperviscosities are applied to simulations with a fixed exponent that must be arbitrarily chosen. Expressing the exponent as a function of the simulation parameters eliminates this ambiguity. These functions are parameterized by comparing the hyperviscous dissipation to the subgrid dissipation calculated from direct numerical simulations. Tests of the parameterization demonstrate that it performs better than using no additional damping term or than using a standard hyperviscosity. Heuristic arguments are presented to extend this hyperviscosity model to three-dimensional (3D) drift-wave turbulence where eddies are highly elongated along the field line. Preliminary results indicate that this generalized 3D hyperviscosity is capable of reducing the resolution requirements for 3D gyrofluid turbulence simulations.

  8. 100-D Ponds closure plan. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petersen, S.W.

    1997-09-01

    The 100-D Ponds is a Treatment, Storage, and Disposal (TSD) unit on the Hanford Facility that received both dangerous and nonregulated waste. This Closure Plan (Rev. 1) for the 100-D Ponds TSD unit consists of a RCRA Part A Dangerous Waste Permit Application (Rev. 3), a RCRA Closure Plan, and supporting information contained in the appendices to the plan. The closure plan consists of eight chapters containing facility description, process information, waste characteristics, and groundwater monitoring data. There are also chapters containing the closure strategy and performance standards. The strategy for the closure of the 100-D Ponds TSD unit ismore » clean closure. Appendices A and B of the closure plan demonstrate that soil and groundwater beneath 100-D Ponds are below cleanup limits. All dangerous wastes or dangerous waste constituents or residues associated with the operation of the ponds have been removed, therefore, human health and the environment are protected. Discharges to the 100-D Ponds, which are located in the 100-DR-1 operable unit, were discontinued in June 1994. Contaminated sediment was removed from the ponds in August 1996. Subsequent sampling and analysis demonstrated that there is no contamination remaining in the ponds, therefore, this closure plan is a demonstration of clean closure.« less

  9. Transcatheter closure of patent ductus arteriosus: past, present and future.

    PubMed

    Baruteau, Alban-Elouen; Hascoët, Sébastien; Baruteau, Julien; Boudjemline, Younes; Lambert, Virginie; Angel, Claude-Yves; Belli, Emre; Petit, Jérôme; Pass, Robert

    2014-02-01

    This review aims to describe the past history, present techniques and future directions in transcatheter treatment of patent ductus arteriosus (PDA). Transcatheter PDA closure is the standard of care in most cases and PDA closure is indicated in any patient with signs of left ventricular volume overload due to a ductus. In cases of left-to-right PDA with severe pulmonary arterial hypertension, closure may be performed under specific conditions. The management of clinically silent or very tiny PDAs remains highly controversial. Techniques have evolved and the transcatheter approach to PDA closure is now feasible and safe with current devices. Coils and the Amplatzer Duct Occluder are used most frequently for PDA closure worldwide, with a high occlusion rate and few complications. Transcatheter PDA closure in preterm or low-bodyweight infants remains a highly challenging procedure and further device and catheter design development is indicated before transcatheter closure is the treatment of choice in this delicate patient population. The evolution of transcatheter PDA closure from just 40 years ago with 18F sheaths to device delivery via a 3F sheath is remarkable and it is anticipated that further improvements will result in better safety and efficacy of transcatheter PDA closure techniques. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  10. [Experience in the treatment of patent ductus arteriosus closure at a mexican hospital].

    PubMed

    Márquez-González, Horacio; Castro-Contreras, Uriel; Cerrud-Sánchez, Carmen Emma; López-Gallegos, Diana; Yáñez-Gutiérrez, Lucelli

    2016-01-01

    The patent ductus arteriosus (PDA) represents one of the most prevalent diseases in hospitals which treat congenital heart diseases (CHD). Currently, in groups of more than 1 year of age percutaneous closure it is the standard therapy. The aim of this paper is to determine the frequency, characteristics and treatment of PCA in congenital heart disease service at the a Cardiology Hospital in Mexico. In clinical CHD our hospital, a descriptive study of 2010-2015 of patients who were treated with percutaneous closure PCA and surgery was performed. They were divided into the following ages: infant, preschool, children, adolescents and adults. The absolute frequencies were recorded. 187 patients of preschool and school which accounted for 60% of the total sample were obtained. Percutaneous closure catheterization was performed in 90%; 2% of complications were recorded. In this clinic, the PCA is treated mostly by interventional catheterization in most stages of the human being with minimal complications.

  11. Primary closure of lawn mower injuries to the foot: a case series.

    PubMed

    Goldsmith, Jon R; Massa, Eric G

    2007-01-01

    The standard initial treatment of lawn mower injuries to the foot consists of prompt administration of parenteral antibiotics, debridement of devitalized tissue, irrigation, repair of traumatized vascular structures, and stabilization of osseous fractures. The primary closure of these wounds at the initial operation is a controversial concept. The authors performed a retrospective study of 9 lawn mower injuries in which primary closure was performed. Medical records were evaluated, and 7 patients were reached for follow-up interviews. The hospital courses for this patient population were remarkably lower than those previously reported in the literature. No patient required further admission to the hospital or surgical intervention. The postinjury functional evaluation mean score was 97.6%. The results demonstrate that this treatment method can be an effective means for treating this mutilating injury in the foot.

  12. 40 CFR 60.111 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...

  13. 40 CFR 60.111 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...

  14. 40 CFR 60.111 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...

  15. 40 CFR 60.111 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...

  16. 40 CFR 60.111 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...

  17. [Perforated peptic ulcer closure: laparoscopic or open?

    PubMed

    Alekberzade, A V; Krylov, N N; Rustamov, E A; Badalov, D A; Popovtsev, M A

    To compare laparoscopic and open closure of perforated peptic ulcer (PPU). The study included 153 patients who underwent PPU suturing. 78 patients underwent laparoscopic closure (laparoscopic group) and open suturing via upper midline laparotomy was performed in 75 cases (open group). Surgery time, postoperative pain severity, time of analgesics intake, postoperative complications, hospital-stay and and cosmetic effect were compared. Laparoscopic PPU closure may be effective and accessible in experienced endoscopic surgeon. It significantly reduces postoperative pain severity, need for analgesics, incidence of postoperative complications and provides excellent cosmetic effect. However, there is greater time of surgery compared with open intervention. There were no significant differences in hspital-stay between groups. Laparoscopic PPU suturing can be considered a good alternative to open surgery. Further researches are needed for standardization, assessment of safety, real advantages and disadvantages of laparoscopic technique.

  18. Performance characteristics of a novel blood bag in-line closure device and subsequent product quality assessment

    PubMed Central

    Serrano, Katherine; Levin, Elena; Culibrk, Brankica; Weiss, Sandra; Scammell, Ken; Boecker, Wolfgang F; Devine, Dana V

    2010-01-01

    BACKGROUND In high-volume processing environments, manual breakage of in-line closures can result in repetitive strain injury (RSI). Furthermore, these closures may be incorrectly opened causing shear-induced hemolysis. To overcome the variability of in-line closure use and minimize RSI, Fresenius Kabi developed a new in-line closure, the CompoFlow, with mechanical openers. STUDY DESIGN AND METHODS The consistency of the performance of the CompoFlow closure device was assessed, as was its effect on component quality. A total of 188 RBC units using CompoFlow blood bag systems and 43 using the standard bag systems were produced using the buffy coat manufacturing method. Twenty-six CompoFlow platelet (PLT) concentrates and 10 control concentrates were prepared from pools of four buffy coats. RBCs were assessed on Days 1, 21, and 42 for cellular variables and hemolysis. PLTs were assessed on Days 1, 3, and 7 for morphology, CD62P expression, glucose, lactate, and pH. A total of 308 closures were excised after processing and the apertures were measured using digital image analysis. RESULTS The use of the CompoFlow device significantly improved the mean extraction time with 0.46 ± 0.11 sec/mL for the CompoFlow units and 0.52 ± 0.13 sec/mL for the control units. The CompoFlow closures showed a highly reproducible aperture after opening (coefficient of variation, 15%) and the device always remained opened. PLT and RBC products showed acceptable storage variables with no differences between CompoFlow and control. CONCLUSIONS The CompoFlow closure devices improved the level of process control and processing time of blood component production with no negative effects on product quality. PMID:20529007

  19. Fatigue Crack Closure Analysis Using Digital Image Correlation

    NASA Technical Reports Server (NTRS)

    Leser, William P.; Newman, John A.; Johnston, William M.

    2010-01-01

    Fatigue crack closure during crack growth testing is analyzed in order to evaluate the critieria of ASTM Standard E647 for measurement of fatigue crack growth rates. Of specific concern is remote closure, which occurs away from the crack tip and is a product of the load history during crack-driving-force-reduction fatigue crack growth testing. Crack closure behavior is characterized using relative displacements determined from a series of high-magnification digital images acquired as the crack is loaded. Changes in the relative displacements of features on opposite sides of the crack are used to generate crack closure data as a function of crack wake position. For the results presented in this paper, remote closure did not affect fatigue crack growth rate measurements when ASTM Standard E647 was strictly followed and only became a problem when testing parameters (e.g., load shed rate, initial crack driving force, etc.) greatly exceeded the guidelines of the accepted standard.

  20. 40 CFR 264.280 - Closure and post-closure care.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 264.280 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land Treatment § 264.280 Closure and post-closure care. (a) During the closure period the owner or...

  1. 40 CFR 264.280 - Closure and post-closure care.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Section 264.280 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land Treatment § 264.280 Closure and post-closure care. (a) During the closure period the owner or...

  2. 40 CFR 264.280 - Closure and post-closure care.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Section 264.280 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land Treatment § 264.280 Closure and post-closure care. (a) During the closure period the owner or...

  3. 40 CFR 264.280 - Closure and post-closure care.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Section 264.280 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land Treatment § 264.280 Closure and post-closure care. (a) During the closure period the owner or...

  4. Optimization and large scale computation of an entropy-based moment closure

    NASA Astrophysics Data System (ADS)

    Kristopher Garrett, C.; Hauck, Cory; Hill, Judith

    2015-12-01

    We present computational advances and results in the implementation of an entropy-based moment closure, MN, in the context of linear kinetic equations, with an emphasis on heterogeneous and large-scale computing platforms. Entropy-based closures are known in several cases to yield more accurate results than closures based on standard spectral approximations, such as PN, but the computational cost is generally much higher and often prohibitive. Several optimizations are introduced to improve the performance of entropy-based algorithms over previous implementations. These optimizations include the use of GPU acceleration and the exploitation of the mathematical properties of spherical harmonics, which are used as test functions in the moment formulation. To test the emerging high-performance computing paradigm of communication bound simulations, we present timing results at the largest computational scales currently available. These results show, in particular, load balancing issues in scaling the MN algorithm that do not appear for the PN algorithm. We also observe that in weak scaling tests, the ratio in time to solution of MN to PN decreases.

  5. Optimization and large scale computation of an entropy-based moment closure

    DOE PAGES

    Hauck, Cory D.; Hill, Judith C.; Garrett, C. Kristopher

    2015-09-10

    We present computational advances and results in the implementation of an entropy-based moment closure, M N, in the context of linear kinetic equations, with an emphasis on heterogeneous and large-scale computing platforms. Entropy-based closures are known in several cases to yield more accurate results than closures based on standard spectral approximations, such as P N, but the computational cost is generally much higher and often prohibitive. Several optimizations are introduced to improve the performance of entropy-based algorithms over previous implementations. These optimizations include the use of GPU acceleration and the exploitation of the mathematical properties of spherical harmonics, which aremore » used as test functions in the moment formulation. To test the emerging high-performance computing paradigm of communication bound simulations, we present timing results at the largest computational scales currently available. Lastly, these results show, in particular, load balancing issues in scaling the M N algorithm that do not appear for the P N algorithm. We also observe that in weak scaling tests, the ratio in time to solution of M N to P N decreases.« less

  6. Transcatheter patent foramen ovale closure versus medical therapy for cryptogenic stroke: a meta-analysis of randomized clinical trials.

    PubMed

    Riaz, Irbaz Bin; Dhoble, Abhijeet; Mizyed, Ahmad; Hsu, Chiu-Hsieh; Husnain, Muhammad; Lee, Justin Z; Lotun, Kapildeo; Lee, Kwan S

    2013-12-11

    There is an association between cryptogenic stroke and patent foramen ovale (PFO). The optimal treatment strategy for secondary prevention remains unclear. The purpose of this study was to analyze aggregate data examining the safety and efficacy of transcatheter device closure versus standard medical therapy in patients with PFO and cryptogenic stroke. A search of published data identified 3 randomized clinical trials for inclusion. The primary outcome was a composite end-point of death, stroke and transient-ischemic attack (TIA). Pre-defined subgroup analysis was performed with respect to baseline characteristics including age, sex, atrial septal aneurysm and shunt size. Data was synthesized using a random effects model and results presented as hazard ratios (HRs) with 95% confidence intervals (CIs). A cohort of 2,303 patients with a history of cryptogenic stroke and PFO were randomized to device closure (n = 1150) and medical therapy (n = 1153). Mean follow-up was 2.5 years. Transcatheter closure was not superior to medical therapy in the secondary prevention of stroke or TIA in intention-to-treat analysis (HR: 0.66, 95% CI: 0.43 to 1.01; p = 0.056). However, the results were statistically significant using per-protocol analysis (HR: 0.64, 95% CI: 0.41 to 0.98; p = 0.043). Males had significant benefit with device closure (HR: 0.48, 95% CI: 0.24 to 0.96; p = 0.038). In this meta-analysis, using intention-to-treat analysis, transcatheter device closure of PFO was not superior to standard medical therapy in the secondary prevention of cryptogenic stroke. Transcatheter closure was superior using per-protocol analysis.

  7. 21 CFR 211.194 - Laboratory records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... specific component, drug product container, closure, in-process material, or drug product, and lot tested... product container, closure, in-process material, or drug product tested. (7) The initials or signature of... of any testing and standardization of laboratory reference standards, reagents, and standard...

  8. Speckle-Tracking Echocardiography in Dogs With Patent Ductus Arteriosus: Effect of Percutaneous Closure on Cardiac Mechanics.

    PubMed

    Spalla, I; Locatelli, C; Zanaboni, A M; Brambilla, P; Bussadori, C

    2016-05-01

    Patent ductus arteriosus (PDA) is 1 of the most common congenital heart defects in dogs and percutaneous closure is effective in achieving ductal closure; PDA closure is associated with abrupt hemodynamic changes. A marked decrease in standard parameters of systolic function as assessed by M- or B-mode echocardiography after PDA closure was identified in previous studies. Speckle tracking echocardiography can provide further insight into the effect of PDA closure on cardiac mechanics in dogs affected by PDA. Twenty-five client-owned dogs with PDA. Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed before and 24 hours after PDA closure, including standard (end-diastolic volumes indexed to body surface area in B- and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B- and M-mode [ESVIB /M ], allometric scaling in diastole [AlloD] and systole [AlloS], pulmonary flow to systemic flow [Qs/Qp], ejection fraction [EF], and fractional shortening [FS]), and advanced speckle-tracking echocardiography (STE): global longitudinal, radial, circumferential and transverse strain (S), and strain rate (SR). Patent ductus arteriosus closure was associated with statistically significant decreases in EDVIM /B and ESVIM /B , AlloD and AlloS, SI, EF, and FS. A statistically significant decrease in the absolute values of radial, transverse, and circumferential S and SR was observed, whereas longitudinal S and SR did not change significantly. Patent ductus arteriosus closure by percutaneous approach is associated with marked decreases of conventional echocardiographic parameters as a result of the changes in loading conditions, but no evidence of systolic dysfunction was identified by means of STE, as none of the S and SR values were below reference ranges. In the short term, contractility is enhanced in the long axis (long S/SR values were not statistically different before and after closure) and decreases to normal values in short axis (circumferential, radial, and transversal S/SR decreased to normal reference range). Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  9. 43 CFR 3809.201 - What should these agreements address?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... Operations must not begin until BLM completes consultation or conferencing under the Endangered Species Act. ... whether Federally proposed or listed threatened or endangered species or their proposed or designated... Policy Act; performance standards; interim management of temporary closure; financial guarantees...

  10. 43 CFR 3809.201 - What should these agreements address?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... Operations must not begin until BLM completes consultation or conferencing under the Endangered Species Act. ... whether Federally proposed or listed threatened or endangered species or their proposed or designated... Policy Act; performance standards; interim management of temporary closure; financial guarantees...

  11. 43 CFR 3809.201 - What should these agreements address?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... Operations must not begin until BLM completes consultation or conferencing under the Endangered Species Act. ... whether Federally proposed or listed threatened or endangered species or their proposed or designated... Policy Act; performance standards; interim management of temporary closure; financial guarantees...

  12. 40 CFR 264.197 - Closure and post-closure care.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 264.197 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES... as hazardous waste, unless § 261.3(d) of this chapter applies. The closure plan, closure activities...

  13. Endoscopic full-thickness resection and defect closure in the colon.

    PubMed

    von Renteln, Daniel; Schmidt, Arthur; Vassiliou, Melina C; Rudolph, Hans-Ulrich; Caca, Karel

    2010-06-01

    Endoscopic full-thickness resection (eFTR) is a minimally invasive method for en bloc resection of GI lesions. The aim of this pilot study was to evaluate the feasibility of a grasp-and-snare technique for eFTR combined with an over-the-scope clip (OTSC) for defect closure. Nonsurvival animal study. Animal laboratory. Fourteen female domestic pigs. The eFTR was performed in porcine colons using a novel tissue anchor in combination with a standard monofilament snare and 14 mm OTSC. In the first group (n = 20), closure of the colonic defects with OTSC was attempted after the resection. In the second group (n = 8), an endoloop was used to secure the resection base before eFTR was performed. In the first group (n = 20), eFTR specimens ranged from 2.4 to 5.5 cm in diameter. Successful closure was achieved in 9 out of 20 cases. Mean burst pressure for OTSC closure was 29.2 mm Hg (range, 2-90; SD, 29.92). Injury to adjacent organs occurred in 3 cases. Lumen obstruction due to the OTSC closure occurred in 3 cases. In the second group (n = 8), the diameter of specimens ranged from 1.2 to 2.2 cm. Complete closure was achieved in all cases, with a mean burst pressure of 76.6 mm Hg (range, 35-120; SD, 31). Lumen obstruction due to the endoloop closure occurred in one case. No other complications or injuries were observed in the second group. Nonsurvival setting. Colonic eFTR using the grasp-and-snare technique is feasible in an animal model. Ligation of the resection base with an endoloop before eFTR seems to reduce complication rates and improve closure success and leak test results despite yielding smaller specimens. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  14. Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.

    PubMed

    Nolan, Winifred P; See, Jovina L; Chew, Paul T K; Friedman, David S; Smith, Scott D; Radhakrishnan, Sunita; Zheng, Ce; Foster, Paul J; Aung, Tin

    2007-01-01

    To evaluate noncontact anterior segment optical coherence technology (AS-OCT) as a qualitative method of imaging the anterior chamber angle and to determine its ability to detect primary angle closure when compared with gonioscopy in Asian subjects. Prospective observational case series. Two hundred three subjects were recruited from glaucoma clinics in Singapore with diagnoses of primary angle closure, primary open-angle glaucoma, ocular hypertension, or cataract. Both eyes (if eligible) of each patient were included in the study. Exclusion criteria were pseudophakia or previous glaucoma surgery. Images of the nasal, temporal, and inferior angles were obtained with AS-OCT in dark and then light conditions. Gonioscopic angle width was graded using the Spaeth classification for each quadrant in low lighting conditions. Angle closure was defined by AS-OCT as contact between the peripheral iris and angle wall anterior to the scleral spur and by gonioscopy as a Spaeth grade of 0 degree (posterior trabecular meshwork not visible). Comparison of the 2 methods in detecting angle closure was done by eye and by individual. Sensitivities and specificities of AS-OCT were calculated using gonioscopy as the reference standard. Complete data were available for 342 eyes of 200 patients. Of the patients, 70.9% had a clinical diagnosis of treated or untreated primary angle closure. Angle closure in > or =1 quadrants was detected by AS-OCT in 142 (71%) patients (228 [66.7%] eyes) and by gonioscopy in 99 (49.5%) patients (152 [44.4%] eyes). The inferior angle was closed more frequently than the nasal or temporal quadrants using both AS-OCT and gonioscopy. When performed under dark conditions, AS-OCT identified 98% of those subjects found to have angle closure on gonioscopy (95% confidence interval [CI], 92.2-99.6) and led to the characterization of 44.6% of those found to have open angles on gonioscopy to have angle closure as well. With gonioscopy as the reference standard, specificity of AS-OCT in the dark was 55.4% (95% CI, 45.2-65.2) for detecting individuals with angle closure. Anterior segment OCT is a rapid noncontact method of imaging angle structures. It is highly sensitive in detecting angle closure when compared with gonioscopy. More persons are found to have closed angles with AS-OCT than with gonioscopy.

  15. Secondary plastic closure of gastroschisis is associated with a lower incidence of mechanical ventilation.

    PubMed

    Dariel, Anne; Poocharoen, Wannisa; de Silva, Nicole; Pleasants, Hazel; Gerstle, Justin Ted

    2015-02-01

    Nonsurgical closure after primary silo placement, secondary plastic closure (SPC), has been used as an alternative to secondary surgical closure (SSC) in gastroschisis. The benefits described were closure without formal surgical procedure, cosmetic aspect, and minimization of intra-abdominal pressures. This study compared requirements for mechanical ventilation and general anesthesia, nutritional care, and outcomes between SPC and SSC. We included patients with primary staged-silo reduction with a 1-year minimum follow-up. SPC was performed at bedside with sedation using a nonadherent dressing. SSC was performed in operating room under general anesthesia using standard surgical techniques. This retrospective study included 64 patients, 23 SPC and 41 SSC. The characteristics of the two groups were comparable. Mechanical ventilation was used for 15 SPC and 41 SSC (p=0.0001) with a comparable median duration (5.5 and 6.0 days, not significant [NS]). General anesthesia was required for 9 SPC and 41 SSC (p<0.0001). Complications included one SPC and six SSC with necrotizing enterocolitis, zero SPC and four SSC with intestinal atresia, two SPC and four SSC with small bowel obstruction, zero SPC and one SSC with abdominal compartment syndrome resulting in a short bowel syndrome (NS). Median duration of parenteral nutrition (30 and 27 days), time to first feeds (14 and 14 days), time at or above minimal enteral feeding (22 and 17 days), time to full feeds (31 and 28 days), length of stay (LOS) in neonatal intensive care unit (24 and 23.5 days) and overall hospital LOS (37 and 36 days) were not statistically different between SPC and SSC patients without complications, respectively. These data were comparable for SPC and SSC patients with complications. Five SPC and six SSC developed an umbilical hernia (NS); two patients in each group required a surgical repair (NS). Plastic closure of gastroschisis after primary silo reduction is simple, safe, reproducible, and associated with a significant lower incidence of mechanical ventilation. Nutritional management and length of hospital stay were similar to conventional surgical closure for patients. Plastic closure allows nonoperative management without general anesthesia at patient's bedside, in comparison with surgical closure that must be performed under general anesthesia in the operating room. Plastic closure does not appear to be associated with more umbilical hernias in this retrospective study. Georg Thieme Verlag KG Stuttgart · New York.

  16. Avoiding Accountability: How Charter Operators Evade Ohio's Automatic Closure Law. K-12 Education

    ERIC Educational Resources Information Center

    DePaoli, Jennifer; van Lier, Piet

    2013-01-01

    Ohio's charter-closure law is touted as one of the toughest in the nation because it requires the automatic closure of charter schools that consistently fail to meet academic standards. Ohio's charter-closure law, which became effective in 2008 and was revised in 2011, calls for automatic closure of schools rated in Academic Emergency for at least…

  17. Avoiding Accountability: How Charter Operators Evade Ohio's Automatic Closure Law. K-12 Education. Executive Summary

    ERIC Educational Resources Information Center

    DePaoli, Jennifer; van Lier, Piet

    2013-01-01

    Ohio's charter-closure law is touted as one of the toughest in the nation because it requires the automatic closure of charter schools that consistently fail to meet academic standards. Ohio's charter-closure law, which became effective in 2008 and was revised in 2011, calls for automatic closure of schools rated in Academic Emergency for at least…

  18. Echocardiographic evaluation of myocardial changes observed after closure of patent ductus arteriosus in dogs.

    PubMed

    Hamabe, L; Kim, S; Yoshiyuki, R; Fukayama, T; Nakata, T M; Fukushima, R; Tanaka, R

    2015-01-01

    Closure of PDA can be associated with echocardiographic changes including deterioration of LV systolic function. Although PDA is commonly encountered in dogs, few comprehensive reports of echocardiographic changes in dogs with PDA closure are available. To evaluate the short-term echocardiographic changes observed after PDA closure in dogs using strain analysis. Seventeen client-owned dogs with left-to-right PDA. Echocardiographic evaluations, including standard echocardiography and two-dimensional tissue tracking (2DTT), were performed before and within 3 days of PDA closure. Preclosure examination showed LV and left atrial dilatation indicating volume overload as a result of PDA. Closure of PDA resulted in significant reduction of LVIDd (<.0001) and LA/Ao (0.01) without change in LVIDs, suggestive of decreased preload. Postclosure LV systolic dysfunction was observed with significant decreased in FS (<.0001) and strain values (P = .0039 for radial strains, P = .0005 for circumferential strains). Additionally, significant LV dyssynchrony (P = .0162) was observed after closure of PDA. Closure of PDA resulted in decreased preload as a result of alleviation of LV volume overload, which in turn caused transient deterioration of LV systolic function. Additionally, this study demonstrated that strain analysis is load dependent. Therefore, care should be taken when interpreting strain measurements as an indicator of LV systolic function. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of American College of Veterinary Internal Medicine.

  19. Uncertainty Analysis for Angle Calibrations Using Circle Closure

    PubMed Central

    Estler, W. Tyler

    1998-01-01

    We analyze two types of full-circle angle calibrations: a simple closure in which a single set of unknown angular segments is sequentially compared with an unknown reference angle, and a dual closure in which two divided circles are simultaneously calibrated by intercomparison. In each case, the constraint of circle closure provides auxiliary information that (1) enables a complete calibration process without reference to separately calibrated reference artifacts, and (2) serves to reduce measurement uncertainty. We derive closed-form expressions for the combined standard uncertainties of angle calibrations, following guidelines published by the International Organization for Standardization (ISO) and NIST. The analysis includes methods for the quantitative evaluation of the standard uncertainty of small angle measurement using electronic autocollimators, including the effects of calibration uncertainty and air turbulence. PMID:28009359

  20. Type of closure prevents microbial contamination of cosmetics during consumer use.

    PubMed Central

    Brannan, D K; Dille, J C

    1990-01-01

    The dispensing closure used for containers plays an important role in protecting cosmetics from in-use microbial contamination. This hypothesis was tested by aseptically packing unpreserved shampoo and skin lotion into containers with three different closure types which provided various degrees of protection against consumer and environmental microbial insults. Shampoo was packed in containers with slit-cap (n = 25), flip-cap (n = 25), or screw-cap (n = 28) closures. Skin lotion was packed in containers with pump-top (n = 21), flip-cap (n = 18), or screw-cap (n = 21) closures. The products were then used by volunteers under actual in-use conditions for 3 (shampoo) or 2 (skin lotion) weeks. After use, the products were evaluated for microbial contamination by using standard methods for enumeration and identification. The standard screw-cap closure provided only minimal protection against microbial contamination of both the shampoo (29% contamination incidence) and the skin lotion (71%). The slit-cap closure on the shampoo container and the flip-cap closure on the skin lotion container provided slightly enhanced degrees of protection (21 and 39% contamination incidence, respectively). The greatest amount of protection (i.e., lowest contamination incidence) was provided by the flip-cap closure for the shampoo container (0%) and the pump-top closure for the skin lotion container (10%). As a result, closure type plays an important role in protecting poorly preserved products from in-use microbial contamination. Images PMID:2339896

  1. Vacuum decay container/closure integrity testing technology. Part 2. Comparison to dye ingress tests.

    PubMed

    Wolf, Heinz; Stauffer, Tony; Chen, Shu-Chen Y; Lee, Yoojin; Forster, Ronald; Ludzinski, Miron; Kamat, Madhav; Mulhall, Brian; Guazzo, Dana Morton

    2009-01-01

    Part 1 of this series demonstrated that a container closure integrity test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method using a VeriPac 325/LV vacuum decay leak tester by Packaging Technologies & Inspection, LLC (PTI) is capable of detecting leaks > or = 5.0 microm (nominal diameter) in rigid, nonporous package systems, such as prefilled glass syringes. The current study compared USP, Ph.Eur. and ISO dye ingress integrity test methods to PTI's vacuum decay technology for the detection of these same 5-, 10-, and 15-microm laser-drilled hole defects in 1-mL glass prefilled syringes. The study was performed at three test sites using several inspectors and a variety of inspection conditions. No standard dye ingress method was found to reliably identify all holed syringes. Modifications to these standard dye tests' challenge conditions increased the potential for dye ingress, and adjustments to the visual inspection environment improved dye ingress detection. However, the risk of false positive test results with dye ingress tests remained. In contrast, the nondestructive vacuum decay leak test method reliably identified syringes with holes > or = 5.0 microm.

  2. The effect of age and sex on facial mimicry: a three-dimensional study in healthy adults.

    PubMed

    Sforza, C; Mapelli, A; Galante, D; Moriconi, S; Ibba, T M; Ferraro, L; Ferrario, V F

    2010-10-01

    To assess sex- and age-related characteristics in standardized facial movements, 40 healthy adults (20 men, 20 women; aged 20-50 years) performed seven standardized facial movements (maximum smile; free smile; "surprise" with closed mouth; "surprise" with open mouth; eye closure; right- and left-side eye closures). The three-dimensional coordinates of 21 soft tissue facial landmarks were recorded by a motion analyser, their movements computed, and asymmetry indices calculated. Within each movement, total facial mobility was independent from sex and age (analysis of variance, p>0.05). Asymmetry indices of the eyes and mouth were similar in both sexes (p>0.05). Age significantly influenced eye and mouth asymmetries of the right-side eye closure, and eye asymmetry of the surprise movement. On average, the asymmetry indices of the symmetric movements were always lower than 8%, and most did not deviate from the expected value of 0 (Student's t). Larger asymmetries were found for the asymmetric eye closures (eyes, up to 50%, p<0.05; mouth, up to 30%, p<0.05 only in the 20-30-year-old subjects). In conclusion, sex and age had a limited influence on total facial motion and asymmetry in normal adult men and women. Copyright © 2010 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Effects of transcatheter closure of Fontan fenestration on exercise tolerance. kidecho@yahoo.com.

    PubMed

    Momenah, Tarek S; Eltayb, Haifa; Oakley, Reida El; Qethamy, Howeida Al; Faraidi, Yahya Al

    2008-05-01

    Baffle fenestration is associated with a significantly better outcome in standard and high-risk patients undergoing completion of Fontan. We report the effects of subsequent transcatheter closure of fenestration on exercise capacity and oxygen saturation. Sixteen patients with a mean age of 10.3 years underwent Amplatzer septal occluder (ASO) device transcatheter closure of Fontan fenestration. All had a fenestrated Fontan operation 6 month to 8 years prior to the procedure. A stress test was performed before and after device closure of fenestration in 14 patients (2 patients did not tolerate stress test before the procedure). The fenestrations in all patients were successfully occluded with the use of the Amplatzer device occluder. No complications occurred during or after the procedure. O2 saturation increased from a mean 85.1 +/- 7.89% to 94.5 +/- 3.63% (p < 0.01) at rest and from 66.2 +/- 12.86% to 87.2 +/- 8.64% (p < 0.01) following exercise. Exercise duration has also increased from 8.22 +/- 2.74 min to 10.29 +/- 1.91 min (p < 0.05). Transcatheter closure of Fontan fenestration increases the duration of exercise capacity and increases O2 saturation at rest and after exercise.

  4. Permanent Closure of MFC Biodiesel Underground Storage Tank 99ANL00013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerry L. Nisson

    2012-10-01

    This closure package documents the site assessment and permanent closure of the Materials and Fuels Complex biodiesel underground storage tank 99ANL00013 in accordance with the regulatory requirements established in 40 CFR 280.71, “Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.”

  5. Development of a score and probability estimate for detecting angle closure based on anterior segment optical coherence tomography.

    PubMed

    Nongpiur, Monisha E; Haaland, Benjamin A; Perera, Shamira A; Friedman, David S; He, Mingguang; Sakata, Lisandro M; Baskaran, Mani; Aung, Tin

    2014-01-01

    To develop a score along with an estimated probability of disease for detecting angle closure based on anterior segment optical coherence tomography (AS OCT) imaging. Cross-sectional study. A total of 2047 subjects 50 years of age and older were recruited from a community polyclinic in Singapore. All subjects underwent standardized ocular examination including gonioscopy and imaging by AS OCT (Carl Zeiss Meditec). Customized software (Zhongshan Angle Assessment Program) was used to measure AS OCT parameters. Complete data were available for 1368 subjects. Data from the right eyes were used for analysis. A stepwise logistic regression model with Akaike information criterion was used to generate a score that then was converted to an estimated probability of the presence of gonioscopic angle closure, defined as the inability to visualize the posterior trabecular meshwork for at least 180 degrees on nonindentation gonioscopy. Of the 1368 subjects, 295 (21.6%) had gonioscopic angle closure. The angle closure score was calculated from the shifted linear combination of the AS OCT parameters. The score can be converted to an estimated probability of having angle closure using the relationship: estimated probability = e(score)/(1 + e(score)), where e is the natural exponential. The score performed well in a second independent sample of 178 angle-closure subjects and 301 normal controls, with an area under the receiver operating characteristic curve of 0.94. A score derived from a single AS OCT image, coupled with an estimated probability, provides an objective platform for detection of angle closure. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    PubMed

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P < .0001, Wilcoxon signed rank test). Overall, gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  7. A programmable quantum current standard from the Josephson and the quantum Hall effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poirier, W., E-mail: wilfrid.poirier@lne.fr; Lafont, F.; Djordjevic, S.

    We propose a way to realize a programmable quantum current standard (PQCS) from the Josephson voltage standard and the quantum Hall resistance standard (QHR) exploiting the multiple connection technique provided by the quantum Hall effect (QHE) and the exactness of the cryogenic current comparator. The PQCS could lead to breakthroughs in electrical metrology like the realization of a programmable quantum current source, a quantum ampere-meter, and a simplified closure of the quantum metrological triangle. Moreover, very accurate universality tests of the QHE could be performed by comparing PQCS based on different QHRs.

  8. To Close or Not to Close: The Very Small Patent Ductus Arteriosus

    PubMed Central

    Fortescue, Elizabeth B.; Lock, James E.; Galvin, Teresa; McElhinney, Doff B.

    2014-01-01

    Patent ductus arteriosus (PDA) accounts for approximately 10% of all congenital heart diseases, with an incidence of at least 2–4 per 1000 term births. Closure of the large, hemodynamically significant PDA is established as the standard of care, and can be performed safely and effectively using either surgical or transcatheter methods. The appropriate management of the very small, hemodynamically insignificant PDA is less clear. Routine closure of such defects has been advocated to eliminate or reduce the risk of infective endocarditis (IE). However, the risk of IE in patients with a small PDA appears to be extremely low, and IE is treatable. Although closure of the small PDA is generally safe and technically successful, it is unknown whether this treatment truly improves the risk : benefit balance compared with observation. In this article, we review the published literature on the natural history and treatment outcomes in individuals with a PDA, the epidemiology and outcomes of IE, particularly in association with PDA, and the rationale and evidence for closure of the very small PDA. PMID:20653702

  9. 43 CFR 3809.420 - What performance standards apply to my notice or plan of operations?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... or facility maintenance after project closure. Long-term, or post-mining, effluent capture and... the Resource Conservation and Recovery Act (42 U.S.C. 6901 et seq.). All garbage, refuse or waste... design. (iv) You must construct a secondary containment system around vats, tanks, or recovery circuits...

  10. 43 CFR 3809.420 - What performance standards apply to my notice or plan of operations?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... or facility maintenance after project closure. Long-term, or post-mining, effluent capture and... the Resource Conservation and Recovery Act (42 U.S.C. 6901 et seq.). All garbage, refuse or waste... design. (iv) You must construct a secondary containment system around vats, tanks, or recovery circuits...

  11. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  12. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  13. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  14. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  15. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  16. Transcatheter closure of atrial septal defects type 2 in children under 3 years of age.

    PubMed

    Knop, Mateusz T; Białkowski, Jacek; Szkutnik, Małgorzata; Fiszer, Roland; Smerdziński, Sebastian; Gałeczka, Michał; Litwin, Linda

    2018-06-04

    Atrial septal defect type II (ASD), according to current standards, is closed percutaneously usually after the child has reached the age of 4-5 years. There are limited data regarding such treatment in smaller infants. To evaluate feasibility, safety and efficacy of percutaneous ASD closure in children under 3 years of age. Overall group of 149 children < 3 years with hemodynamically significant ASD, who underwent effective transcatheter ASD closure in one tertiary center between 1999 and 2014 were included. Mean procedural age of treated children was 2,2 years and weight 12,5 kg. In all nitinol wire mesh devices were applied (mostly Amplatzer Septal Occluders). ASD was closed by standard technique (except few cases when left disc of implant was inserted initially into right pulmonary vein to prevent oblique position of the device). Complications related to the procedure were divided into major and minor ones. There were 97 children with a single ASD and 52 with double/multiple ASD. No death, no implant embolization, and one major complications occurred during procedure and in follow-up. ASD was completely closed in all but 8 patients with double/multiple ASD. Right ventricle diameter normalization occurred in all during 1 year follow-up. In majority of the patients in follow-up an acceleration of physical development and resolution of accompanying morbidity was observed. Percutaneous ASD device closure can be performer safely in children below 3 years of age with low risk of complication during and after the procedure.

  17. Automated analysis of angle closure from anterior chamber angle images.

    PubMed

    Baskaran, Mani; Cheng, Jun; Perera, Shamira A; Tun, Tin A; Liu, Jiang; Aung, Tin

    2014-10-21

    To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by κ statistic and comparison of area under receiver operating characteristic curves (AUC). One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (κ = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (κ = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  18. Speech and phonology in Swedish-speaking 3-year-olds with unilateral complete cleft lip and palate following different methods for primary palatal surgery.

    PubMed

    Klintö, Kristina; Svensson, Henry; Elander, Anna; Lohmander, Anette

    2014-05-01

    Objective : To describe and compare speech and phonology at age 3 years in children born with unilateral complete cleft lip and palate treated with three different methods for primary palatal surgery. Design : Prospective study. Setting : Primary care university hospitals. Participants : Twenty-eight Swedish-speaking children born with nonsyndromic unilateral complete cleft lip and palate. Interventions : Three methods for primary palatal surgery: two-stage closure with soft palate closure between 3.4 and 6.4 months and hard palate closure at mean age 12.3 months (n = 9) or 36.2 months (n = 9) or one-stage closure at mean age 13.6 months (n = 10). Main Outcome Measures : Based on independent judgments performed by two speech-language pathologists from standardized video recordings: percent correct consonants adjusted for age, percent active cleft speech characteristics, total number of phonological processes, number of different phonological processes, hypernasality, and audible nasal air leakage. The hard palate was unrepaired in nine of the children treated with two-stage closure. Results : The group treated with one-stage closure showed significantly better results than the group with an unoperated hard palate regarding percent active cleft speech characteristics and total number of phonological processes. Conclusions : Early primary palatal surgery in one or two stages did not result in any significant differences in speech production at age 3 years. However, children with an unoperated hard palate had significantly poorer speech and phonology than peers who had been treated with one-stage palatal closure at about 13 months of age.

  19. The Integration of the 241-Z Building Decontamination and Decommissioning Under Cercla with RCRA Closure at the Plutonium Finishing Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mattlin, E.; Charboneau, S.; Johnston, G.

    2007-07-01

    The 241-Z treatment and storage tanks, a hazardous waste Treatment, Storage and Disposal (TSD) unit permitted pursuant to the Resource Conservation and Recovery Act of 1976 (RCRA) and Washington State Hazardous Waste Management Act, RCW 70.105, , have been deactivated and are being actively decommissioned under the provisions of the Hanford Federal Facility Agreement and Consent Order (HFFACO), RCRA and Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) 42 U.S.C. 9601 et seq. The 241-Z TSD unit managed non-listed radioactive contaminated waste water, containing trace RCRA characteristic constituents. The 241-Z TSD unit consists of below grade tanks (D-4,more » D-5, D-7, D-8, and an overflow tank) located in a concrete containment vault, sample glovebox GB-2-241-ZA, and associated ancillary piping and equipment. The tank system is located beneath the 241-Z building. The 241-Z building is not a portion of the TSD unit. The sample glovebox is housed in the above-grade building. Waste managed at the TSD unit was received via underground piping from Plutonium Finishing Plant (PFP) sources. Tank D-6, located in the D-6 vault cell, is a past-practice tank that was taken out of service in 1972 and has never operated as a portion of the RCRA TSD unit. CERCLA actions will address Tank D-6, its containment vault cell, and soil beneath the cell that was potentially contaminated during past-practice operations and any other potential past-practice contamination identified during 241-Z closure, while outside the scope of the Hanford Facility Dangerous Waste Closure Plan, 241-Z Treatment and Storage Tanks. Under the RCRA closure plan, the 241-Z TSD unit is anticipated to undergo clean closure to the performance standards of the State of Washington with respect to dangerous waste contamination from RCRA operations. The TSD unit will be clean closed if physical closure activities identified in the plan achieve clean closure standards for all 241-Z locations. Clean closed 241-Z treatment and storage tanks, equipment and/or structures will remain after RCRA clean closure for future disposition in conjunction with PFP decommissioning activities which are integrated with CERCLA. (authors)« less

  20. The influence of injury severity on complication rates after primary closure or colostomy for penetrating colon trauma.

    PubMed Central

    Nelken, N; Lewis, F

    1989-01-01

    The management of penetrating colon injury has been frequently debated in the literature, yet few reports have evaluated primary closure versus diverting colostomy in similarly injured patients. Diverting colostomy is the standard of care when mucosal penetration is present, but primary closure in civilian practice has generally had excellent results, although it has been restricted to less severely injured patients. Because the degree of injury may influence choice of treatment in modern practice, various indices of injury severity have been proposed for assessment of patients with penetrating colon trauma. As yet, however, there has been no cross-comparison of repair type versus injury severity. A retrospective study 76 patients who sustained penetrating colon trauma between January 1, 1979 and December 31, 1985 and who survived for at least 24 hours was conducted. Different preferences among attending surgeons and a more aggressive approach to the use of primary closure during the years of study led to an essentially random use of primary closure and diverting colostomy for moderate levels of colon injury, with mandatory colostomy reserved for the most serious injuries. Primary closure was performed in 37 patients (three having resection and anastomosis), and colostomy was performed in 39 patients. Severity of injury was evaluated by the Injury Severity Score (ISS), Penetrating Abdominal Trauma Index (PATI), and the Flint Colon Injury Score. Complications and outcome were evaluated as a function of severity of injury, and primary closure and colostomy were compared. Demographic profiles of the two groups did not differ regarding age, sex, mechanism of injury, shock, or delay between injury and operation. The mortality rate was 2.6% for each group. Major morbidity, including septic complications, occurred in 11% of the patients of the primary closure group and in 49% of those of the colostomy group. When PATI was less than 25, the Flint score was less than or equal to 2, or when the ISS was less than 25, primary closure resulted in fewer complications than did colostomy. Of the injury severity indices examined, the PATI most reliably predicted complications and specifically identified patients who whose outcome would be good with primary repair. These results suggest that the use of primary closure should be expanded in civilian penetrating colon trauma and that, even with moderate degrees of colon injury, primary closure provides an outcome equivalent to that provided by colostomy. In addition, the predictive value of the PATI suggests that it should be included along with other injury severity indices in trauma data bases. Images Fig. 3. Fig. 4. PMID:2930290

  1. 46 CFR 64.41 - Stop valve closure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Stop valve closure. 64.41 Section 64.41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Standards for an MPT § 64.41 Stop valve closure. A stop valve that operates by a screwed...

  2. 45 CFR 303.11 - Case closure criteria.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... the best interests of the child to establish paternity in a case involving incest or forcible rape, or... 45 Public Welfare 2 2011-10-01 2011-10-01 false Case closure criteria. 303.11 Section 303.11... STANDARDS FOR PROGRAM OPERATIONS § 303.11 Case closure criteria. (a) The IV-D agency shall establish a...

  3. Trends in State Charter School Laws: Authorizers, Caps, Performance-Based Closures and Virtual Schools

    ERIC Educational Resources Information Center

    Christie, Kathy; Millard, Maria; Thomsen, Jennifer; Wixom, Micah

    2014-01-01

    Forty-two states and the District of Columbia have enacted charter school legislation. The Education Commission of the States (ECS) analysts reviewed laws in the 50 states in creating an online database that highlights how state charter school laws vary, particularly in how states establish standards and accountability for charter school…

  4. Closure of hazardous and mixed radioactive waste management units at DOE facilities. [Contains glossary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This is document addresses the Federal regulations governing the closure of hazardous and mixed waste units subject to Resource Conservation and Recovery Act (RCRA) requirements. It provides a brief overview of the RCRA permitting program and the extensive RCRA facility design and operating standards. It provides detailed guidance on the procedural requirements for closure and post-closure care of hazardous and mixed waste management units, including guidance on the preparation of closure and post-closure plans that must be submitted with facility permit applications. This document also provides guidance on technical activities that must be conducted both during and after closure ofmore » each of the following hazardous waste management units regulated under RCRA.« less

  5. Water-tight knee arthrotomy closure: comparison of a novel single bidirectional barbed self-retaining running suture versus conventional interrupted sutures.

    PubMed

    Nett, Michael; Avelar, Rui; Sheehan, Michael; Cushner, Fred

    2011-03-01

    Standard medial parapatellar arthrotomies of 10 cadaveric knees were closed with either conventional interrupted absorbable sutures (control group, mean of 19.4 sutures) or a single running knotless bidirectional barbed absorbable suture (experimental group). Water-tightness of the arthrotomy closure was compared by simulating a tense hemarthrosis and measuring arthrotomy leakage over 3 minutes. Mean total leakage was 356 mL and 89 mL in the control and experimental groups, respectively (p = 0.027). Using 8 of the 10 knees (4 closed with control sutures, 4 closed with an experimental suture), a tense hemarthrosis was again created, and iatrogenic suture rupture was performed: a proximal suture was cut at 1 minute; a distal suture was cut at 2 minutes. The impact of suture rupture was compared by measuring total arthrotomy leakage over 3 minutes. Mean total leakage was 601 mL and 174 mL in the control and experimental groups, respectively (p = 0.3). In summary, using a cadaveric model, arthrotomies closed with a single bidirectional barbed running suture were statistically significantly more water-tight than those closed using a standard interrupted technique. The sample size was insufficient to determine whether the two closure techniques differed in leakage volume after suture rupture.

  6. Catheter Closure Through a Venous Approach of Patent Ductus Arteriosus in Small Pediatric Patients Using Combined Angiographic and Echocardiographic Guidance.

    PubMed

    Thanopoulos, Basil Vasilios D; Ninios, Vlassis; Dardas, Petros; Giannopoulos, Andreas; Deleanou, Dan; Iancovici, Silvia

    2016-11-15

    The standard technique of catheter closure of patent ductus arteriosus (PDA) may be associated with arterial complications particularly in small pediatric patients. The aim of this study was to evaluate whether catheter closure of PDA in small children using an exclusive venous approach is a safe and effective alternative to closure with the standard technique. One hundred-twelve patients, aged 2 to 24 months, were randomly assigned in a 1:1 ratio to catheter closure of PDA using the standard technique (group 1) and an exclusive venous approach (group 2), respectively. In group 2, the procedure was guided using hand injections of contrast media through the delivery sheath and 2-dimensional and color Doppler echocardiography. Group 1: the PDA diameter ranged from 2 to 5.5 mm and the device diameter ranged from 4 to 8 mm. The PDA occluders were permanently implanted in all patients. Five losses of the arterial pulses that were restored with intravenous infusion of heparin and recombinant tissue plasminogen activator (rtPA), and 4 groin hematomas were the main complications of the procedure. Group 2: the mean PDA diameter ranged from 2.5 to 6 mm and the device diameter ranged from 3 to 8 mm. The PDA occluders were permanently implanted in all but 2 patients. There were no complications. Complete echocardiographic closure of PDA at 1-month follow-up was observed in all 110 patients. Exclusive transvenous PDA occlusion is an effective and safe technique that prevents the arterial complications of the standard approach in small children. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. A randomized study comparing skin closure in cesarean sections: staples vs subcuticular sutures.

    PubMed

    Rousseau, Julie-Anne; Girard, Karine; Turcot-Lemay, Lucile; Thomas, Nancy

    2009-03-01

    We sought to compare postoperative pain according to the skin closure method (subcuticular sutures vs staples) after an elective term cesarean section. A randomized controlled trial of 101 women was performed. Women were randomly assigned to subcuticular sutures or staples. Operative technique and postoperative analgesia were standardized. Stratification was used for primary vs repeat cesareans. Analog pain and satisfaction scales ranging from 0-10 were completed at postoperative days 1 and 3, and at 6 weeks postoperatively. A digital photograph of the incision was taken at 6 weeks postoperatively and evaluated by 3 independent blinded observers. Pain at 6 weeks postoperatively was significantly less in the staple group (0.17 vs 0.51; P = .04). Operative time was shorter in that group (24.6 vs 32.9 minutes; P < .0001). No difference was noted for incision appearance and women's satisfaction. Staples are the method of choice for skin closure for elective term cesareans in our population.

  8. Post-Closure Inspection Report for the Tonopah Test Range, Nevada, For Calendar Year 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    This report provides the results of the annual post-closure inspections conducted at the closed Corrective Action Units (CAUs) located on the Tonopah Test Range (TTR), Nevada. This report covers calendar year 2011 and includes inspection and repair activities completed at the following CAUs: (1) CAU 400: Bomblet Pit and Five Points Landfill (TTR); (2) CAU 407: Roller Coaster RadSafe Area (TTR); (3) CAU 424: Area 3 Landfill Complexes (TTR); (4) CAU 453: Area 9 UXO Landfill (TTR); and (5) CAU 487: Thunderwell Site (TTR) Inspections were conducted according to the post-closure plans in the approved Closure Reports. The post-closure inspectionmore » plan for each CAU is included in Appendix B. The inspection checklists are included in Appendix C, field notes are included in Appendix D, and photographs taken during inspections are included in Appendix E. The annual post-closure inspections were conducted May 3 and 4, 2011. Maintenance was performed at CAU 424, CAU 453, and CAU 487. At CAU 424, two surface grade monuments at Landfill Cell A3-3 could not be located during the inspection. The two monuments were located and marked with lava rock on July 13, 2011. At CAU 453, there was evidence of animal burrowing. Animal burrows were backfilled on July 13, 2011. At CAU 487, one use restriction warning sign was missing, and wording was faded on the remaining signs. A large animal burrow was also present. The signs were replaced, and the animal burrow was backfilled on July 12, 2011. As a best management practice, the use restriction warning signs at CAU 407 were replaced with standard Federal Facility Agreement and Consent Order signs on July 13, 2011. Vegetation monitoring was performed at the CAU 400 Five Points Landfill and CAU 407 in June 2011, and the vegetation monitoring report is included in Appendix F.« less

  9. Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results

    PubMed Central

    Sinha, Santosh Kumar; Razi, Mahmadula; Pandey, Rama Niwas; Kumar, Prakash; Krishna, Vinay; Jha, Mukesh Jitendra; Mishra, Vikas; Asif, Mohammad; Abdali, Nasar; Tewari, Pradyot; Thakur, Ramesh; Pandey, Umeshwar; Varma, Chandra Mohan

    2017-01-01

    Objective: To evaluate the feasibility, safety, and efficacy of a novel Cocoon Duct Occluder device for the transcatheter closure (TCC) of large patent ductus arteriosus (PDA). Methods: In this prospective, non-randomized study, consecutive patients with large PDA (narrowest diameter: ≥3.5/4.0 mm in symptomatic/asymptomatic patients, respectively), who underwent TCC with Cocoon Duct Occluder at our institute between November, 2012 and June, 2016 were examined. TCC was performed using the standard technique, and devices were antegradely delivered via 6–10F delivery sheaths. Device embolization, residual shunt, hemolysis, left pulmonary artery (LPA) stenosis, procedural and fluoroscopy time, and mortality were assessed. Patients were followed-up by transthoracic echocardiography with color Doppler imaging at 24 h (D1), 1 month (D30), and 6 months (D180) after implantation. Results: A total of 57 patients (age: 11.7±2.8 years; weight: 22.3±3.5 kg) were enrolled. The mean narrowest diameter was 7.4±0.7 mm. The PDA closure was successfully performed in each patient. Fluoroscopy and procedural time was 6.7±3.2 min and 23.9±2.7 min, respectively. Postprocedural angiography revealed that 49 (85.9%) patients had immediate and complete closure, whereas 8 (14.1%) had residual shunt. Color Doppler imaging at D1 revealed complete closure in 52 (91.3%) patients. At D30, complete closure was reported in all patients and was maintained at D180. Hemolysis, embolization, obstruction of LPA or descending aorta, and death were not reported till D180. Conclusion: TCC using Cocoon Duct Occluder is feasible, safe, and effective in the management of patients with large PDA, with excellent results on short- and medium-term follow-up. PMID:29145233

  10. 10 CFR 60.112 - Overall system performance objective for the geologic repository after permanent closure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... repository after permanent closure. 60.112 Section 60.112 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH-LEVEL RADIOACTIVE WASTES IN GEOLOGIC REPOSITORIES Technical Criteria Performance Objectives § 60.112 Overall system performance objective for the geologic repository after permanent closure...

  11. Deep inferior epigastric artery perforator flap donor-site closure with cannula-assisted, limited undermining, and progressive high-tension sutures versus standard abdominoplasty: complications, sensitivity, and cosmetic outcomes.

    PubMed

    Visconti, Giuseppe; Tomaselli, Federica; Monda, Anna; Barone-Adesi, Liliana; Salgarello, Marzia

    2015-01-01

    In deep inferior epigastric artery perforator (DIEP) flap breast reconstruction, abdominal donor-site cosmetic and sensibility outcomes and the closure technique have drawn little attention in the literature, with many surgeons still following the principles of standard abdominoplasty. In this article, the authors report their experience with the cannula-assisted, limited undermining, and progressive high-tension suture ("CALP") technique of DIEP donor-site closure compared with standard abdominoplasty. Between December of 2008 and January of 2013, 137 consecutive women underwent DIEP flap breast reconstruction. Of these, 82 patients (between December of 2008 and November of 2011) underwent DIEP flap donor-site closure by means of standard abdominoplasty (control group) and 55 patients (from December of 2011 to January of 2013) by means of cannula-assisted, limited undermining, and progressive high-tension suture (study group). The abdominal drainage daily output, donor-site complications, abdominal skin sensitivity at 1-year follow-up, cosmetic outcomes, and patient satisfaction were recorded and analyzed statistically. Daily drainage output was significantly lower in the study group. Donor-site complications were significantly higher in the control group (37.8 percent versus 9 percent). Seroma and wound healing problems were experienced in the control group. Abdominal skin sensibility was better preserved in the study group. Overall, abdominal wall aesthetic outcomes were similar in both groups, except for scar quality (better in the study group). According to the authors' experience, cannula-assisted, limited undermining, and progressive high-tension suture should be always preferred to standard abdominoplasty for DIEP donor-site closure to reduce the complication rate to improve abdominal skin sensitivity and scar quality. Therapeutic, II.

  12. Goose-neck snare-assisted transcatheter ASD closure: A safety procedure for large and complex ASDs.

    PubMed

    Butera, Gianfranco; Lovin, Nicusor; Basile, Domenica Paola; Carminati, Mario

    2016-04-01

    To report on a new technique that increases the safety of percutaneous atrial septal defect (ASD) closure using a goose-neck snare system. ASD transcatheter closure is a widespread procedure. However, in some cases, ASDs may be large and with soft rims. In these situation, a potential risk exists for device malposition or embolization. When transesophageal echocardiography (TEE) evaluation and balloon sizing showed large defects with floppy rims the chosen Amplatzer device was implanted in a standard way. In large defects with floppy rims, before release a 5-mm goose-neck snare with its 4 Fr catheter was placed across the delivery cable and fixed to catch the screwing mechanism of implanted Amplatzer device. The delivery cable was unscrewed and the device reached its final position without any tension. If the position was considered satisfactory the device was released from the goose-neck snare. Thirteen patients had a snare-assisted ASD transcatheter closure. Median device size was 24 mm (range 14-38 mm). Retrieval or repositioning of the device using the goose-neck snare was performed in four cases: in three patients, because of device malposition after delivery cable release and in one patient, because of unsuitability of closure of a second significant defect. Furthermore, in two subjects with multiple ASDs, a second fenestration looked quite significant with the device still attached to the delivery cable while it appeared smaller after release. Snare-assisted Amplatzer ASD device placement is a new method for ASD percutaneous closure and adds safety to the procedure. © 2016 Wiley Periodicals, Inc.

  13. Keyhole Fracture of the Skull

    DTIC Science & Technology

    2008-12-01

    unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Keyhole Fracture of the Skull irrigation and drainage of the penetrating...skull injury without craniotomy , and repair of the laceration via advancement flap Fig. 3. Diagram of forces involved in creation of keyhole...midline shift was noted. Helical CT scan performed the following day after debridement, irrigation, drainage , and closure of the gunshot wound showed

  14. Dynamical System Analysis of Reynolds Stress Closure Equations

    NASA Technical Reports Server (NTRS)

    Girimaji, Sharath S.

    1997-01-01

    In this paper, we establish the causality between the model coefficients in the standard pressure-strain correlation model and the predicted equilibrium states for homogeneous turbulence. We accomplish this by performing a comprehensive fixed point analysis of the modeled Reynolds stress and dissipation rate equations. The results from this analysis will be very useful for developing improved pressure-strain correlation models to yield observed equilibrium behavior.

  15. 40 CFR 265.110 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Closure... through 265.115 (which concern closure) apply to the owners and operators of all hazardous waste...

  16. 40 CFR 264.110 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Closure and Post....115 (which concern closure) apply to the owners and operators of all hazardous waste management...

  17. An estimate of pocket closure and avoided needs of surgery after scaling and root planing with systemic antibiotics: a systematic review.

    PubMed

    Kolakovic, Mirela; Held, Ulrike; Schmidlin, Patrick R; Sahrmann, Philipp

    2014-12-22

    Relevant benefits of adjunctive medication of antibiotica after conventional root surface debridement in terms of enhanced pocket depth (PD) reduction have been shown. However, means and standard deviations of enhanced reductions are difficult to translate into clinical relevant treatment outcomes such as pocket resolution or avoidance of additional surgical interventions. Accordingly, the aim of this systematic review was to calculate odds ratios for relevant cut-off values of PD after mechanical periodontal treatment with and without antibiotics, specifically the combination of amoxicilline and metronidazol, from published studies. As clinical relevant cut-off values "pocket closure" for PD ≤ 3mm and "avoidance of surgical intervention" for PD ≤ 5 mm were determined. The databases PubMed, Embase and Central were searched for randomized clinical studies assessing the beneficial effect of the combination of amoxicillin and metronidazole after non-surgical mechanical debridement. Titles, abstracts and finally full texts were scrutinized for possible inclusion by two independent investigators. Quality and heterogeneity of the studies were assessed and the study designs were examined. From published means and standard deviations for PD after therapy, odds ratios for the clinically relevant cut-off values were calculated using a specific statistical approach. Meta-analyses were performed for the time points 3 and 6 month after mechanical therapy. Generally, a pronounced chance for pocket closure from 3 to 6 months of healing was shown. The administration of antibiotics resulted in a 3.55 and 4.43 fold higher probability of pocket closure after 3 and 6 months as compared to mechanical therapy alone. However, as the estimated risk for residual pockets > 5 mm was 0 for both groups, no odds ratio could be calculated for persistent needs for surgery. Generally, studies showed a moderate to high quality and large heterogeneity regarding treatment protocol, dose of antibiotic medication and maintenance. With the performed statistical approach, a clear benefit in terms of an enhanced chance for pocket closure by co-administration of the combination of amoxicillin and metronidazole as an adjunct to non-surgical mechanical periodontal therapy has been shown. However, data calculation failed to show a benefit regarding the possible avoidance of surgical interventions.

  18. Closure of colostomy.

    PubMed Central

    Beck, P H; Conklin, H B

    1975-01-01

    We analyzed the records of 77 cases of loop colostomy closure in Vietnam War Casualties. All records were complete from the date of injury to discharge following colostomy closure. Simple of the loop colostomy was performed in 44 patients and resection of the stoma and reanastomosis of bowel segments was performed in 33 patients. Average operating time for simple closure of the loop was 70 minutes compared to 115 minutes for resection and anastomosis. Nasogastric suction was used less frequently and for a shorter time with simple loop closure. The total postoperative complication rate was 9% with simple loop closure as compared to 24% for resection and anastomosis. Simple closure of the loop described in this report is technically easier and as safe as resection of the stoma and reanastomosis. Images Fig. 1. PMID:1094967

  19. Generalized kinetic-neoclassical closure for parallel viscosity in a tokamak.

    NASA Astrophysics Data System (ADS)

    Smolyakov, A.; Callen, J. D.; Hegna, C.

    2000-10-01

    We develop a drift-kinetic equation for a Chapman Enskog-type calculations of the parallel viscosity in a tokamak. This approach allows us to uniformly obtain closure relations for the parallel viscosity that include the kinetic effects of wave-particle interactions, such as those of Hammet-Perkins closures, as well as standard neoclassical moment closures induced by collisions and the magnetic field strength variation along field lines. Closures for both these cases can be obtained from our expressions; also, their mutual influences can be investigated. The developed equations allow calculation of parallel vicosity in general kinetic-neoclassical regimes while the main conservation properties remain correct even with an approximate treatment of the collisional operator.

  20. Directly ventricular septal defect closure without using arteriovenous wire loop: Our adult case series using transarterial retrograde approach

    PubMed Central

    Pekel, Nihat; Ercan, Ertuğrul; Özpelit, Mehmet Emre; Özyurtlu, Ferhat; Yılmaz, Akar; Topaloğlu, Caner; Saygı, Serkan; Yakan, Serkan; Tengiz, İstemihan

    2017-01-01

    Objective: The standard transcatheter ventricular septal defects (VSD) closure procedure is established with arteriovenous (AV) loop and is called as antegrade approach. The directly retrograde transarterial VSD closure without using AV loop might be better option as shortens the procedure time and decreases radiation exposure. Methods: Our series consist of twelve sequential adult cases with congenital VSDs (seven with perimembranous, four with muscular, one with postoperative residuel VSD). The mean age was 26.9 (Range 18–58), the mean height was 168.75 cm (Range 155–185cm), and the mean body mass index was 23.4 (Range 17.3–28.4). Maximum and minimum defect sizes were 10 and 5 mm and the mean defect size was 6.24 mm. The procedure was performed with left heart catheterization and advancing the delivery sheath over the stiff exchange wire then VSD occlusion from left side. Results: The defects were successfully closed with this technique in eleven patients. In sixth patient, the defect could not be cannulated by the delivery sheath, as the tip of the sheath did not reach the defect and VSD was closed with same sheath by standard transvenous approach using AV loop. We didn’t encounter any complication releated to semilunar or atrioventricular valves. Atrioventricular conduction system was not affected by the procedure in any patients. The median procedure and fluoroscopy times were 66 and 16.5 minutes respectively. Conclusion: Transarterial retrograde VSD closure without using AV loop simplifies the procedure, decreases the radiation exposure, and shortens the procedure time. The only limitation in adult patients is delivery sheath length. PMID:28315566

  1. Outcomes of mechanical stapling for postlaryngectomy open pharyngotomy closure.

    PubMed

    Paddle, Paul; Husain, Inna; McHugh, Lauren; Franco, Ramon

    2017-03-01

    A total laryngectomy (TL) is performed as a primary or salvage therapy for laryngeal carcinoma. Pharyngotomy closure after TL is typically performed using manual sutures. Automatic stapling devices are routinely used in thoracoabdominal surgery, but have not been widely accepted for use in pharyngotomy closure. Previously described closed stapling techniques of pharyngeal closure do not allow direct evaluation of surgical margins and are limited to endolaryngeal disease. We describe an open technique for pharyngotomy closure using a mechanical stapling device. Retrospective review. A review was conducted of 16 total laryngectomies performed from May 2008 to August 2015 utilizing an Ethicon Endopath ETS Compact-Flex 45 stapler. Sixteen patients (15 male, one female), mean age 69 years, received open TL (14 salvage, two primary) with endostapler pharyngeal closure and primary tracheoesophageal puncture (TEP). Surgical time averaged 218 minutes. Median time to swallowing was 4 days (range, 2-240 days) and mean hospital stay 6 days (range, 3-10 days). Fistula incidence was 31% (5/16) overall and 36% (5/14) in the postradiation patients. Mechanical stapling is a simple method for postlaryngectomy open pharyngotomy closure. This technique allows evaluation of margins, easy primary TEP, and the opportunity for early swallowing and shorter hospital stays. In addition, it can be performed for closure of salvage laryngectomies with rates of fistula formation similar to that found in the literature using suture closure techniques. Future studies are necessary to compare oncological results and surgical complications between the open and closed stapling techniques and to traditional suture closure. 4 Laryngoscope, 127:605-610, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  2. RETINA EXPANSION TECHNIQUE FOR MACULAR HOLE APPOSITION REPORT 2: Efficacy, Closure Rate, and Risks of a Macular Detachment Technique to Close Large Full-Thickness Macular Holes.

    PubMed

    Wong, Roger; Howard, Catherine; Orobona, Giancarlo Dellʼaversana

    2018-04-01

    To describe the safety and efficacy of a technique to close large thickness macular holes. A consecutive retrospective interventional case series of 16 patients with macular holes greater than 650 microns in "aperture" diameter were included. The technique involves vitrectomy, followed by internal limiting membrane peeling. The macula is detached using subretinal injection of saline. Fluid-air exchange is performed to promote detachment and stretch of the retina. After this, the standard fluid-air exchange is performed and perfluoropropane gas is injected. Face-down posturing is advised. Adverse effects, preoperative, and postoperative visual acuities were recorded. Optical coherence tomography scans were also taken. The mean hole size was 739 microns (SD: 62 microns; mean base diameter: 1,311 microns). Eighty-three percent (14 of 16) of eyes had successful hole closure after the procedure. At 12-month follow-up, no worsening in visual acuity was reported, and improvement in visual acuity was noted in 14 of 16 eyes. No patients lost vision because of the procedure. It is possible to achieve anatomical closure of large macular holes using RETMA. No patients experienced visual loss. The level of visual improvement is likely limited because of the size and chronicity of these holes.

  3. The Economic Impact of Closed-Incision Negative-Pressure Therapy in High-Risk Abdominal Incisions: A Cost-Utility Analysis.

    PubMed

    Chopra, Karan; Gowda, Arvind U; Morrow, Chris; Holton, Luther; Singh, Devinder P

    2016-04-01

    Complex abdominal wall reconstruction is beset by postoperative complications. A recent meta-analysis comparing the use of closed-incision negative-pressure therapy to standard dressings found a statistically significant reduction in surgical-site infection. The use of closed-incision negative-pressure therapy is gaining acceptance in this population; however, the economic impact of this innovative dressing remains unknown. In this study, a cost-utility analysis was performed assessing closed-incision negative-pressure therapy and standard dressings following closure of abdominal incisions in high-risk patients. Cost-utility methodology involved reviewing literature related to closed-incision negative-pressure therapy in abdominal wall surgery, obtaining utility estimates to calculate quality-adjusted life-year scores for successful surgery and surgery complicated by surgical-site infection, summing costs using Medicare Current Procedural Terminology codes, and creating a decision tree illuminating the most cost-effective dressing strategy. One-way sensitivity analysis was performed to assess the robustness of the results. The aforementioned meta-analysis comparing closed-incision negative-pressure therapy to standard dressings included a subset of five studies assessing abdominal wall surgery in 829 patients (260 closed-incision negative-pressure therapy and 569 standard dressings). Decision tree analysis revealed an estimated savings of $1546.52 and a gain of 0.0024 quality-adjusted life-year with closed-incision negative-pressure therapy compared with standard dressings; therefore, closed-incision negative-pressure therapy is a dominant treatment strategy. One-way sensitivity analysis revealed that closed-incision negative-pressure therapy is a cost-effective option when the surgical-site infection rate is greater than 16.39 percent. The use of closed-incision negative-pressure therapy is cost-saving following closure of abdominal incisions in high-risk patients.

  4. 40 CFR 264.178 - Closure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Closure. 264.178 Section 264.178 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR... from the containment system. Remaining containers, liners, bases, and soil containing or contaminated...

  5. 40 CFR 265.228 - Closure and post-closure care.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 265.228 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... or operator must: (1) Remove or decontaminate all waste residues, contaminated containment system...

  6. Initial experience with the Cardiva Boomerang vascular closure device in diagnostic catheterization.

    PubMed

    Doyle, Brendan J; Godfrey, Michael J; Lennon, Ryan J; Ryan, James L; Bresnahan, John F; Rihal, Charanjit S; Ting, Henry H

    2007-02-01

    The authors studied the safety and efficacy of the Cardiva Boomerang vascular closure device in patients undergoing diagnostic cardiac catheterization. Conventional vascular closure devices (sutures, collagen plugs, or metal clips) have been associated with catastrophic complications including arterial occlusion and foreign body infections; furthermore, they cannot be utilized in patients with peripheral vascular disease or vascular access site in a vessel other than the common femoral artery. The Cardiva Boomerang device facilitates vascular hemostasis without leaving any foreign body behind at the access site, can be used in peripheral vascular disease, and can be used in vessels other than the common femoral artery A total of 96 patients undergoing transfemoral diagnostic cardiac catheterization were included in this study, including 25 (26%) patients with contraindications to conventional closure devices. Femoral angiography was performed prior to deployment of the Cardiva Boomerang closure device. Patients were ambulated at 1 hr after hemostasis was achieved. The device was successfully deployed and hemostasis achieved with the device alone in 95 (99%) patients. The device failed to deploy in 1 (1%) patient and required conversion to standard manual compression. Minor complications were observed in 5 (5%) patients. No patients experienced major complications including femoral hematoma > 4 cm, red blood cell transfusion, retroperitoneal bleed, arteriovenous fistula, pseudoaneurysm, infection, arterial occlusion, or vascular surgery. The Cardiva Boomerang device is safe and effective in patients undergoing diagnostic cardiac catheterization using the transfemoral approach, facilitating early ambulation with low rates of vascular complications. (c) 2006 Wiley-Liss, Inc.

  7. Contamination of injectable solutions with 2-mercaptobenzothiazole leached from rubber closures.

    PubMed

    Reepmeyer, J C; Juhl, Y H

    1983-11-01

    An impurity, discovered in a sample of digoxin injectable solution commercially packaged in a syringe for single-dose delivery, was found to originate from the rubber closure of the syringe and was identified as 2-mercaptobenzothiazole, a common accelerator for rubber vulcanization. Several similarly packaged injectable solutions of a variety of drugs from various manufacturers were examined and over half contained 2-mercaptobenzothiazole. The compound was identified by UV spectrophotometry (including a pH-dependent shift in its absorbance maximum), by mass spectrometry, and by comparison with standard 2-mercaptobenzothiazole using silica gel and reverse-phase high-performance liquid chromatography (HPLC). The presence of this impurity in injectable solutions may have implications with regard to toxicity and may interfere with the assay of digoxin injectable solution by HPLC.

  8. Prospective, randomized, controlled trial of polymer cable ties versus standard wire closure of midline sternotomy.

    PubMed

    Marasco, Silvana F; Fuller, Louise; Zimmet, Adam; McGiffin, David; Seitz, Michael; Ch'ng, Stephanie; Gangahanumaiah, Shivanand; Bailey, Michael

    2018-04-16

    Midline sternotomy remains the most common access incision for cardiac operations. Traditionally, the sternum is closed with stainless steel wires. Wires are well known to stretch and break, however, leading to pain, nonunion, and potential deep sternal wound infection. We hypothesized that biocompatible plastic cable ties would achieve a more rigid sternal fixation, reducing postoperative pain and analgesia requirements. A prospective, randomized study compared the ZIPFIX (De Puy Synthes, West Chester, Pa) sternal closure system (n = 58) with standard stainless steel wires (n = 60). Primary outcomes were pain and analgesia requirements in the early postoperative period. Secondary outcome was sternal movement, as assessed by ultrasound at the postoperative follow-up visit. Groups were well matched in demographic and operative variables. There were no significant differences between groups in postoperative pain, analgesia, or early ventilatory requirements. Patients in the ZIPFIX group had significantly more movement in the sternum and manubrium on ultrasound at 4 weeks. ZIPFIX sternal cable ties provide reliable closure but no demonstrable benefit in this study in pain or analgesic requirements relative to standard wire closure after median sternotomy. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  9. 40 CFR 265.113 - Closure; time allowed for closure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... includes an amended waste analysis plan, ground-water monitoring and response program, human exposure....113 Section 265.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND...

  10. 40 CFR 265.110 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Closure... the owners and operators of: (1) All hazardous waste disposal facilities; (2) Waste piles and surface... through 265.115 (which concern closure) apply to the owners and operators of all hazardous waste...

  11. Kleene Algebra and Bytecode Verification

    DTIC Science & Technology

    2016-04-27

    computing the star (Kleene closure) of a matrix of transfer functions. In this paper we show how this general framework applies to the problem of Java ...bytecode verification. We show how to specify transfer functions arising in Java bytecode verification in such a way that the Kleene algebra operations...potentially improve the performance over the standard worklist algorithm when a small cutset can be found. Key words: Java , bytecode, verification, static

  12. Randomized controlled multicentre study comparing biological mesh closure of the pelvic floor with primary perineal wound closure after extralevator abdominoperineal resection for rectal cancer (BIOPEX-study)

    PubMed Central

    2014-01-01

    Background Primary perineal wound closure after conventional abdominoperineal resection (cAPR) for rectal cancer has been the standard of care for many years. Since the introduction of neo-adjuvant radiotherapy and the extralevator APR (eAPR), oncological outcome has been improved, but at the cost of increased rates of perineal wound healing problems and perineal hernia. This has progressively increased the use of biological meshes, although not supported by sufficient evidence. The aim of this study is to determine the effectiveness of pelvic floor reconstruction using a biological mesh after standardized eAPR with neo-adjuvant (chemo)radiotherapy compared to primary perineal wound closure. Methods/Design In this multicentre randomized controlled trial, patients with a clinical diagnosis of primary rectal cancer who are scheduled for eAPR after neo-adjuvant (chemo)radiotherapy will be considered eligible. Exclusion criteria are prior radiotherapy, sacral resection above S4/S5, allergy to pig products or polysorbate, collagen disorders, and severe systemic diseases affecting wound healing, except for diabetes. After informed consent, 104 patients will be randomized between standard care using primary wound closure of the perineum and the experimental arm consisting of suturing a biological mesh derived from porcine dermis in the pelvic floor defect, followed by perineal closure similar to the control arm. Patients will be followed for one year after the intervention and outcome assessors and patients will be blinded for the study treatment. The primary endpoint is the percentage of uncomplicated perineal wound healing, defined as a Southampton wound score of less than II on day 30. Secondary endpoints are hospital stay, incidence of perineal hernia, quality of life, and costs. Discussion The BIOPEX-study is the first randomized controlled multicentre study to determine the additive value of using a biological mesh for perineal wound closure after eAPR with neo-adjuvant radiotherapy compared to primary perineal wound closure with regard to perineal wound healing and the occurrence of perineal hernia. Trail registration number NCT01927497 (Clinicaltrial.gov). PMID:25163547

  13. Endoscopic closure of duodenal perforations by using an over-the-scope clip: a randomized, controlled porcine study.

    PubMed

    von Renteln, Daniel; Rudolph, Hans-Ulrich; Schmidt, Arthur; Vassiliou, Melina C; Caca, Karel

    2010-01-01

    Duodenal perforations during diagnostic upper endoscopy are rare; however, when therapeutic techniques are performed, the reported incidence is as great as 2.8%. Surgical repair is usually mandated, but it is associated with significant morbidity and mortality. To compare closure of duodenal perforations by using an over-the-scope clip (OTSC) with a surgical closure. Randomized, controlled animal study. Animal facility laboratory. Domestic pigs (24 females). Large (10-mm) duodenal perforations were created by using an endoscopic needle-knife. The animals were randomly assigned to either open surgical repair (n=12) or endoscopic closure by using the OTSC system (n=12). Pressurized leak tests were performed during necropsy. One major bleed occurred because of a liver injury during creation of the duodenotomy. Mean time for endoscopic closure was 5 minutes (range, 3-8 min; SD +/- 2). No complications occurred during any of the closure procedures. At necropsy, all OTSC and surgical closures demonstrated complete sealing of duodenotomy sites. Pressurized leak tests demonstrated a mean burst pressure of 166 mm Hg (range, 80-260; SD +/- 65) for OTSC closures and 143 mm Hg (range, 30-300, SD +/- 83) for surgical sutures. Ex vivo intact duodenal specimens exhibited a mean burst pressure of 247 mm Hg (range, 200-300; SD +/- 35), which was significantly higher compared with in vivo OTSC and surgical closures (P < .01). There were no significant differences between burst pressures of OTSC and surgical closures (P = .461). Nonsurvival setting. Endoscopic closure of duodenal perforations by using the OTSC system is comparable with surgical closure in a nonsurvival porcine model. This technique is easy to perform and seems suitable for repairing duodenal perforations. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  14. The Influence of Closing Poor Performing Primary Schools on the Educational Attainment of Students

    ERIC Educational Resources Information Center

    De Witte, Kristof; Van Klaveren, Chris

    2014-01-01

    This paper examines whether the closure of poor performing primary schools improved students' educational attainment. It is believed that school closure affects children's educational outcomes positively because children switch to better primary schools. At the same time, school closure creates a social disturbance such that educational outcomes…

  15. THE U.S. EPA'S VISION FOR A BEACH FORECASTING TOOL

    EPA Science Inventory

    Beach closures due to water quality that exceeds standard limits occur frequently in the United States. These beach closures deprive the public of opportunities for recreational activities and can have a significant impact on local economics. Because of the large number of mari...

  16. A novel one-shot circular stapler closure for atrial septal defect in a beating-heart porcine model.

    PubMed

    Tarui, Tatsuya; Tomita, Shigeyuki; Ishikawa, Norihiko; Ohtake, Hiroshi; Watanabe, Go

    2015-02-01

    In surgical atrial septal defect (ASD) closure, there are no techniques or devices that can close the ASD accurately in a short time under a beating heart. We have developed a simple and automatic ASD closure technique using a circular stapler. This study assessed the feasibility and efficacy of a new circular stapler closure for ASD. Under a continuous beating heart, hand-sewn patch plasty ASD closure was performed in 6 pigs (group A) and circular stapler ASD closure was performed in 6 pigs (group B). The time to close the ASD and the effectiveness of the closure were compared. Closure was significantly faster in group B (10.5 ± 1.0 seconds) than in group A (664 ± 10 seconds; p < 0.05). There was no leakage at the closure site, and sufficient tolerance was confirmed. A circular stapler can be used to treat ASD faster than hand-sewn patch plasty, with sufficient pressure tolerance in a beating heart porcine model. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Comparison of W-Plasty vs Traditional Straight-Line Techniques for Primary Paramedian Forehead Flap Donor Site Closure.

    PubMed

    Jáuregui, Emmanuel J; Tummala, Neelima; Seth, Rahul; Arron, Sarah; Neuhaus, Isaac; Yu, Siegrid; Grekin, Roy; Knott, P Daniel

    2016-07-01

    The paramedian forehead flap (PMFF) donor site scar is hard to disguise and may be a source of patient dissatisfaction. To evaluate the aesthetic outcome of W-plasty vs traditional straight-line (SL) closure techniques of the PMFF donor site. A retrospective cohort study was conducted at the University of California, San Francisco Medical Center. Clinical history and operative reports were reviewed for 31 patients who underwent a PMFF procedure performed between November 1, 2011, and May 29, 2014. Blinded photographic analysis of postoperative photographs was performed. The pedicled component of the PMFF was raised primarily with either a W-plasty or traditional SL design. Standard photographs of the donor site, obtained at least 90 days after surgery, were reviewed and scored in a blinded fashion by 4 dermatologic surgeons using a 100-point visual analog scale (from 0 [worst possible outcome] to 100 [best possible outcome]) and a 5-point Likert scale (from very poor to excellent). Interrater reliability was assessed via Cronbach α testing. All 31 forehead flaps survived during this study period; 16 PMFFs were raised with the W-plasty technique and 15 were raised with the SL technique. The W-plasty and SL groups were similar in terms of age, sex, and race/ethnicity (mean [SD] age, 68.4 [12.4] vs 61.8 [11.6] years; 13 [84%] vs 9 [60%] men; and 15 [94%] vs 13 [87%] white). Patients undergoing W-plasty closure had significantly higher mean visual analog scale scores compared with those undergoing SL closure (72.8 [18.3] vs 65.6 [18.1]; P = .03). Mean Likert scale scores for W-plasty were higher than those for SL closure, but the difference was not significant (3.77 [1.02] vs 3.43 [0.98]; P = .08). Overall interrater reliability for the visual analog scale and Likert scale scores were 0.67 and 0.58, respectively. Patients undergoing PMFF donor site closure using a primary W-plasty technique demonstrated better mean scar appearance of the forehead donor site compared with SL closure. The primary W-plasty technique did not result in any PMFF losses and should be considered for appropriate patients. 3.

  18. Expected outcomes from topical haemoglobin spray in non-healing and worsening venous leg ulcers.

    PubMed

    Arenberger, P; Elg, F; Petyt, J; Cutting, K

    2015-05-01

    To evaluate the effect of topical haemoglobin spray on treatment response and wound-closure rates in patients with chronic venous leg ulcers. A linear regression model was used to forecast healing outcomes over a 12-month period. Simulated data were taken from normal distributions based on post-hoc analysis of a 72-patient study in non-healing and worsening wounds (36 patients receiving standard care and 36 receiving standard care plus topical haemoglobin spray). Using a simulated 25,000 'patients' from each group, the proportion of wound closure over time was projected. Simulation results predicted a 55% wound closure rate at six months in the haemoglobin group, compared with 4% in the standard care group. Over a 12-month simulation period, a 43% overall reduction in wound burden was predicted. With the haemoglobin spray, 85% of wounds were expected to heal in 12 months, compared with 13% in the standard care group. Topical haemoglobin spray promises a more effective treatment for chronic venous leg ulcers than standard care alone in wounds that are non-healing or worsening. Further research is required to validate these predictions and to identify achievable outcomes in other chronic wound types.

  19. Safety and feasibility of intra-operative device closure of atrial septal defect with transthoracic minimal invasion.

    PubMed

    Chen, Qiang; Cao, Hua; Zhang, Gui-Can; Chen, Liang-Wan; Chen, Dao-Zhong

    2012-01-01

    The study aims to evaluate the safety and feasibility of intra-operative device closure of atrial septal defect with transthoracic minimal invasion. From May 2006 to June 2009, 252 patients with secundum-type atrial septal defect closure were enrolled in our institution. The patients were divided into two groups, with 182 patients in group I with intra-operative device closure and 72 in group II with surgical closure. In group I, the patients' age ranged from 3 months to 62 years (mean±standard deviation, 19.0±16.7 years). This approach involved a transthoracic minimal invasion that was performed after full evaluation of the atrial septal defect by transthoracic echocardiography, deploying the device through the delivery sheath to occlude the atrial septal defect. In group I, 180 patients were occluded successfully under this approach. The size of the occluder device implanted ranged from 6 to 48 mm. Minor complications occurred, which included transient arrhythmias (n=23) and pleural effusion (n=15). Two patients with postoperative cardiac arrest were successfully cardiopulmonary resuscitated. Another two patients with occluder dislodged back into the right atrium were turned to surgical repair with cardiopulmonary bypass on the postoperative day. In group II, all patients were occluded successfully, and almost all patients needed blood transfusion and suffered from various minor complications. All discharged patients were followed up for 1-5 years. During this period, we found no recurrence, no thrombosis, even no device failure. In our comparative studies, group II had significantly longer intensive care unit (ICU) stay and hospital stay than group I (p<0.05). The cost for group I was less than group II (p<0.05). Intra-operative device closure of atrial septal defect with transthoracic minimal invasion is a safe and feasible technique. It had the advantages of cost savings, yielding better cosmetic results, and leaving less trauma than surgical closure.

  20. Meta-analysis of transcatheter closure versus medical therapy for patent foramen ovale in prevention of recurrent neurological events after presumed paradoxical embolism.

    PubMed

    Agarwal, Shikhar; Bajaj, Navkaranbir Singh; Kumbhani, Dharam J; Tuzcu, E Murat; Kapadia, Samir R

    2012-07-01

    In this study, a meta-analysis of observational studies was performed to compare the rate of recurrent neurological events (RNE) between transcatheter closure and medical management of patients with cryptogenic stroke/transient ischemic attack (TIA) and concomitant patent foramen ovale (PFO). A significant controversy surrounds the optimal strategy for treatment of cryptogenic stroke/TIA and coexistent PFO. We conducted a MEDLINE search with standard search terms to determine eligible studies. Adjusted incidence rates of RNE were 0.8 (95% confidence interval [CI]: 0.5 to 1.1) events and 5.0 (95% CI: 3.6 to 6.9) events/100 person-years (PY) in the transcatheter closure and medical management arms, respectively. Meta-analysis of the limited number of comparative studies and meta-regression analysis suggested that the transcatheter closure might be superior to the medical therapy in prevention of RNE after cryptogenic stroke. Comparison of the anticoagulation and antiplatelet therapy subgroups of the medical arm yielded a significantly lower risk of RNE within patients treated with anticoagulants. Device-related complications were encountered at the rate of 4.1 (95% CI: 3.2 to 5.0) events/100 PY, with atrial arrhythmias being the most frequent complication. After transcatheter closure, RNE did not seem to be related to the pre-treatment shunt size or the presence of residual shunting in the follow-up period. Significant benefit of transcatheter PFO closure was apparent in elderly patients, patients with concomitant atrial septal aneurysm, and patients with thrombophilia. Rates of RNE with transcatheter closure and medical therapy in patients presenting with cryptogenic stroke or TIA were estimated at 0.8 and 5.0 events/100 PY. Further randomized controlled trials are needed to conclusively compare these 2 management strategies. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Transcatheter closure of calcified patent ductus arteriosus in older adult patients: Immediate and 12-month follow-up results.

    PubMed

    Gu, Xinghua; Zhang, Qiuwang; Sun, Hourong; Fei, Jianchun; Zhang, Xiquan; Kutryk, Michael J

    2017-05-01

    To present our experience in transcatheter closure of calcified patent ductus arteriosus (PDA) in older adult patients, which has rarely been reported. From 2009 to 2014, a total of 16 patients (median age 58 years) with calcified PDA underwent transcatheter closure in our center. All patients were symptomatic with major symptoms being exertional dyspnea (in 12), palpitations (in 8), and fatigue (in 5). A continuous murmur was heard in all patients. The median ductus diameter was 4 mm (range 3-7 mm). The median Qp/Qs was 1.6 (range 1.4-2.9). Transcatheter closure was performed for all patients. The size of the occluder selected was 2-3 mm greater than the narrowest portion of PDA. We experienced difficulties in advancing the multipurpose catheter through the calcified duct in about one third of patients (5/16). Considering that calcified tissue has a greater tendency to rupture, hence, to close PDA in these patients, they adopted the retrograde wire-assisted technique and modified the procedure to reduce the shear stress of sheath and avoid any sheath kinking. For the remaining 11 patients, the advancement of the multipurpose catheter through the calcified duct was smooth and the conventional antegrade approach was applied. Clinical examination, standard 12-lead electrocardiography, chest x-ray, and transthoracic echocardiography were performed before hospital discharge, at 1-, 3-, 6-, and 12-months follow-ups. All PDAs were successfully closed. There were no deaths. Three patients had a trivial residual shunt, with one also having intravascular hemolysis. Following pharmacological treatment, hemolysis signs vanished at 7 days postprocedure. The trivial residual shunt disappeared in all three patients at 3-month follow-up. No new-onset residual shunt, device embolization, device dislocation, infective endocarditis, or embolism was observed at all follow-up time points. Successful closure of calcified PDA with few complications in older adult patients was achieved using the duct occluder. © 2016 Wiley Periodicals, Inc.

  2. 40 CFR 63.962 - Standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... shall control air emissions from the individual drain system using one or a combination of the following... closure device. (3) Junction box control requirements. Each junction box shall be equipped with controls as follows: (i) The junction box shall be equipped with a closure device (e.g., manhole cover, access...

  3. 40 CFR 63.962 - Standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... shall control air emissions from the individual drain system using one or a combination of the following... closure device. (3) Junction box control requirements. Each junction box shall be equipped with controls as follows: (i) The junction box shall be equipped with a closure device (e.g., manhole cover, access...

  4. 40 CFR 63.962 - Standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... shall control air emissions from the individual drain system using one or a combination of the following... closure device. (3) Junction box control requirements. Each junction box shall be equipped with controls as follows: (i) The junction box shall be equipped with a closure device (e.g., manhole cover, access...

  5. 40 CFR 63.962 - Standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... shall control air emissions from the individual drain system using one or a combination of the following... closure device. (3) Junction box control requirements. Each junction box shall be equipped with controls as follows: (i) The junction box shall be equipped with a closure device (e.g., manhole cover, access...

  6. 30 CFR 57.4603 - Closure of valves.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Closure of valves. 57.4603 Section 57.4603 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...

  7. 30 CFR 56.4603 - Closure of valves.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Closure of valves. 56.4603 Section 56.4603 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...

  8. 40 CFR 264.113 - Closure; time allowed for closure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....113 Section 264.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES... the final volume of hazardous wastes, or the final volume of non-hazardous wastes if the owner or...

  9. 40 CFR 280.71 - Permanent closure and changes-in-service.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Permanent closure and changes-in-service. 280.71 Section 280.71 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID... for Occupational Safety and Health “Criteria for a Recommended Standard * * * Working in Confined...

  10. Parasitology: United Kingdom National Quality Assessment Scheme.

    PubMed Central

    Hawthorne, M.; Chiodini, P. L.; Snell, J. J.; Moody, A. H.; Ramsay, A.

    1992-01-01

    AIMS: To assess the results from parasitology laboratories taking part in a quality assessment scheme between 1986 and 1991; and to compare performance with repeat specimens. METHODS: Quality assessment of blood parasitology, including tissue parasites (n = 444; 358 UK, 86 overseas), and faecal parasitology, including extra-intestinal parasites (n = 205; 141 UK, 64 overseas), was performed. RESULTS: Overall, the standard of performance was poor. A questionnaire distributed to participants showed that a wide range of methods was used, some of which were considered inadequate to achieve reliable results. Teaching material was distributed to participants from time to time in an attempt to improve standards. CONCLUSIONS: Since the closure of the IMLS fellowship course in 1972, fewer opportunities for specialised training in parasitology are available: more training is needed. Poor performance in the detection of malarial parasites is mainly attributable to incorrect speciation, misidentification, and lack of equipment such as an eyepiece graticule. PMID:1452791

  11. Do we need a femoral artery route for transvenous PDA closure in children with ADO-I?

    PubMed

    Baykan, Ali; Narin, Nazmi; Özyurt, Abdullah; Argun, Mustafa; Pamukçu, Özge; Onan, Sertaç H; Sezer, Sadettin; Baykan, Zeynep; Üzüm, Kazım

    2015-03-01

    The standard procedure in percutaneous closure of patent ductus arteriosus (PDA) with Amplatzer duct occluder-I (ADO-I) is transvenous closure guided by aortic access through femoral artery. The current study aims to compare the procedures for PDA closure with ADO-I: only transvenous access with the standard procedure. This study was designed retrospectively and 101 pediatric patients were included. PDA closure was done by only femoral venous access in 19 of them (group 1), arterial and venous access used in 92 patients (group 2) between 2004 to 2012 years. The position of the device and residual shunt in group1 was evaluated by the guidance of the aortogram obtained during the return phase of the pulmonary artery injection and guidance of transthoracic echocardiography. Shapiro-Wilk's test, Mann-Whitney U, chi-squared tests were used for statistical comparison. The procedure was successful in 18 (95%) patients in group 1 and 90 (98%) patients in group 2. Complications including the pulmonary artery embolization (n=1), protrusion to pulmonary artery (n=1), inguinal hematoma (n=3), bleeding (n=2) were only detected in group 2. In other words, while complications were observed in 7 (7.2%) patients in group 2, no minor/major complication was observed in group 1. Complete closure in group 1 was: in catheterization room 14 (77.8%), at 24th hour in 2 (11.1%), at first month in 2 (11.1%). Complete closure in group 2 was: 66 (73.4%) patients in the catheterization room, 21 (23.3%) at 24th hour, 3 (3.3%) at first month, complete closure occurred at the end of first month. In percutaneouse PDA closure via ADO-I, this technique can be a choice for patients whose femoral artery could not be accessed, or access is impossible/contraindicated. But for the reliability and validity of this method, randomized multicenter clinical studies are necessary.

  12. Do we need a femoral artery route for transvenous PDA closure in children with ADO-I?

    PubMed Central

    Baykan, Ali; Narin, Nazmi; Özyurt, Abdullah; Argun, Mustafa; Pamukçu, Özge; Onan, Sertaç H.; Sezer, Sadettin; Baykan, Zeynep; Üzüm, Kazım

    2015-01-01

    Objective: The standard procedure in percutaneous closure of patent ductus arteriosus (PDA) with Amplatzer duct occluder-I (ADO-I) is transvenous closure guided by aortic access through femoral artery. The current study aims to compare the procedures for PDA closure with ADO-I: only transvenous access with the standard procedure. Methods: This study was designed retrospectively and 101 pediatric patients were included. PDA closure was done by only femoral venous access in 19 of them (group 1), arterial and venous access used in 92 patients (group 2) between 2004 to 2012 years. The position of the device and residual shunt in group1 was evaluated by the guidance of the aortogram obtained during the return phase of the pulmonary artery injection and guidance of transthoracic echocardiography. Shapiro-Wilk’s test, Mann-Whitney U, chi-squared tests were used for statistical comparison. Results: The procedure was successful in 18 (95%) patients in group 1 and 90 (98%) patients in group 2. Complications including the pulmonary artery embolization (n=1), protrusion to pulmonary artery (n=1), inguinal hematoma (n=3), bleeding (n=2) were only detected in group 2. In other words, while complications were observed in 7 (7.2%) patients in group 2, no minor/major complication was observed in group 1. Complete closure in group 1 was: in catheterization room 14 (77.8%), at 24th hour in 2 (11.1%), at first month in 2 (11.1%). Complete closure in group 2 was: 66 (73.4%) patients in the catheterization room, 21 (23.3%) at 24th hour, 3 (3.3%) at first month, complete closure occurred at the end of first month. Conclusion: In percutaneouse PDA closure via ADO-I, this technique can be a choice for patients whose femoral artery could not be accessed, or access is impossible/contraindicated. But for the reliability and validity of this method, randomized multicenter clinical studies are necessary. PMID:25333978

  13. The etiology and determinants of hospital closure.

    PubMed

    Longo, D R; Sohn, M W; Shortell, S M

    1996-01-01

    This article examines the etiology of hospital closure and the correlates of hospital closure and the extent of similarity in this organizational outcome between pre- and post-Prospective Payment System (PPS) implementation. It also replicates a study from an earlier time period. Findings support the study's main hypotheses: in more stringent and turbulent markets, institutional and strategic variables are more important determinants of hospital closure. Merger acquisitions are found to be similar to both system acquisitions and autonomous hospitals. Standard Metropolitan Statistical Area (SMSA) status and regulation show an effect on hospital closure and merger acquisition. While many similarities exist when compared to the replicated study and findings prior to PPS implementation, it appears that sufficient differences exist to support the hypothesis that the PPS has an impact upon hospital organizational outcome.

  14. CLOSURE REPORT FOR CORRECTIVE ACTION UNIT 528: POLYCHLORINATED BIPHENYLS CONTAMINATION NEVADA TEST SITE, NEVADA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BECHTEL NEVADA

    2006-09-01

    This Closure Report (CR) describes the closure activities performed at CAU 528, Polychlorinated Biphenyls Contamination, as presented in the Nevada Division of Environmental Protection (NDEP)-approved Corrective Action Plan (CAP) (US. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSAINSO], 2005). The approved closure alternative was closure in place with administrative controls. This CR provides a summary of the completed closure activities, documentation of waste disposal, and analytical data to confirm that the remediation goals were met.

  15. 50 CFR 622.34 - Gulf EEZ seasonal and/or area closures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...′47″ S 28°30′51″ 82°52′55″ T 28°27′46″ 82°55′09″ U 28°30′51″ 82°52′09″ 1 Crystal River Entrance Light... (l) will begin on the same date and time as the Texas closure unless circumstances dictate otherwise.... the following day. All times are eastern standard time. During these closures, a person aboard a...

  16. 50 CFR 622.34 - Gulf EEZ seasonal and/or area closures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...′47″ S 28°30′51″ 82°52′55″ T 28°27′46″ 82°55′09″ U 28°30′51″ 82°52′09″ 1 Crystal River Entrance Light... (l) will begin on the same date and time as the Texas closure unless circumstances dictate otherwise... day. All times are eastern standard time. During these closures, a person aboard a vessel using or...

  17. 50 CFR 622.34 - Gulf EEZ seasonal and/or area closures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...′47″ S 28°30′51″ 82°52′55″ T 28°27′46″ 82°55′09″ U 28°30′51″ 82°52′09″ 1 Crystal River Entrance Light... same date and time as the Texas closure unless circumstances dictate otherwise. (2) Eastern zone. The... to 6:00 a.m. the following day. All times are eastern standard time. During these closures, a person...

  18. 40 CFR 265.112 - Closure plan; amendment of plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND.... By May 19, 1981, or by six months after the effective date of the rule that first subjects a facility... description of other activities necessary during the partial and final closure periods to ensure that all...

  19. 40 CFR 146.73 - Financial responsibility for post-closure care.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Financial responsibility for post... Standards Applicable to Class I Hazardous Waste Injection Wells § 146.73 Financial responsibility for post-closure care. The owner or operator shall demonstrate and maintain financial responsibility for post...

  20. 40 CFR 146.73 - Financial responsibility for post-closure care.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 24 2013-07-01 2013-07-01 false Financial responsibility for post... Standards Applicable to Class I Hazardous Waste Injection Wells § 146.73 Financial responsibility for post-closure care. The owner or operator shall demonstrate and maintain financial responsibility for post...

  1. 40 CFR 266.102 - Permit standards for burners.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...

  2. 40 CFR 266.102 - Permit standards for burners.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...

  3. 40 CFR 266.102 - Permit standards for burners.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...

  4. 40 CFR 266.102 - Permit standards for burners.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...

  5. 40 CFR 266.102 - Permit standards for burners.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...

  6. 40 CFR 265.120 - Certification of completion of post-closure care.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... each hazardous waste disposal unit, the owner or operator must submit to the Regional Administrator, by registered mail, a certification that the post-closure care period for the hazardous waste disposal unit was...) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT...

  7. 40 CFR 146.73 - Financial responsibility for post-closure care.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Financial responsibility for post... Standards Applicable to Class I Hazardous Waste Injection Wells § 146.73 Financial responsibility for post-closure care. The owner or operator shall demonstrate and maintain financial responsibility for post...

  8. Performance of Kobryn-Gusarov-Kovalenko closure from a thermodynamic viewpoint for one-component Lennard-Jones fluids

    NASA Astrophysics Data System (ADS)

    Miyata, Tatsuhiko; Tange, Kentaro

    2018-05-01

    The performance of Kobryn-Gusarov-Kovalenko (KGK) closure was examined in terms of the thermodynamics for one-component Lennard-Jones fluids. The result was compared to molecular dynamics simulation as well as to hypernetted chain, Kovalenko-Hirata (KH), Percus-Yevick and Verlet-modified closures. As the density increases, the error of KGK closure shows a turnover, regarding the excess internal energy, pressure and isothermal compressibility. On the other hand, it was numerically confirmed that the energy and the virial equations are consistent under both KH and KGK closures. The accuracies of density-derivative and temperature-derivative of the radial distribution function are also discussed.

  9. Technical Feasibility of Enterotomy Closure with Knotless Barbed Suture Material (V-Loc 180) in Esophagojejunostomy Using Linear Stapler during Totally Laparoscopic Total Gastrectomy for Gastric Cancer.

    PubMed

    Kim, Dong Jin; Kim, Wook; Lee, Jun Hyun

    2017-08-01

    Intra-corporeal esophagojejunostomy (EJ) using a linear stapler creates a stapler entry hole that requires secure closure during the totally laparoscopic total gastrectomy (TLTG) procedure for gastric cancer. Since a standard method has not been established yet, the feasibility of using V-loc 180 (Covidien, Mansfield, MA, USA) suture material was evaluated in this study. During January 2012 to March 2015, 25 patients who underwent linear stapling EJ and V-loc 180 closure of remaining enterotomy were included in this study. Basic clinico-pathological characteristics, surgical outcomes, and short-term complications were analyzed. The mean patient age was 60.4 ± 8.5 years. Nineteen males and six females were included in this study. The mean body mass index was 25.3 ± 2.3 kg/m 2 . There were 22 stage-I, 2 stage-II, and 1 stage-III gastric cancer patients. The mean operation time was 240.5 ± 44.6 min, and the time for anastomosis was 38.8 ± 11.2 min. The procedures were successfully performed in all cases without any intra-operative complications. There was one case of EJ leakage that occurred at the corner of EJ staple line and not at the enterotomy closure site. The closure of the remaining enterotomy site using V-loc 180 suture following linear stapler EJ is technically feasible and safe during the TLTG procedure. However, further experience and results from other surgeons are necessary to generalize this procedure.

  10. Hand-suture versus stapling for closure of loop ileostomy: HASTA-Trial: a study rationale and design for a randomized controlled trial

    PubMed Central

    2011-01-01

    Background Colorectal cancer is the second most common tumor in developed countries, with a lifetime prevalence of 5%. About one third of these tumors are located in the rectum. Surgery in terms of low anterior resection with mesorectal excision is the central element in the treatment of rectal cancer being the only option for definite cure. Creating a protective diverting stoma prevents complications like anastomotic failure and meanwhile is the standard procedure. Bowel obstruction is one of the main and the clinically and economically most relevant complication following closure of loop ileostomy. The best surgical technique for closure of loop ileostomy has not been defined yet. Methods/Design A study protocol was developed on the basis of the only randomized controlled mono-center trial to solve clinical equipoise concerning the optimal surgical technique for closure of loop ileostomy after low anterior resection due to rectal cancer. The HASTA trial is a multi-center pragmatic randomized controlled surgical trial with two parallel groups to compare hand-suture versus stapling for closure of loop ileostomy. It will include 334 randomized patients undergoing closure of loop ileostomy after low anterior resection with protective ileostomy due to rectal cancer in approximately 20 centers consisting of German hospitals of all level of health care. The primary endpoint is the rate of bowel obstruction within 30 days after ileostomy closure. In addition, a set of surgical and general variables including quality of life will be analyzed with a follow-up of 12 months. An investigators meeting with a practical session will help to minimize performance bias and enforce protocol adherence. Centers are monitored centrally as well as on-site before and during recruitment phase to assure inclusion, treatment and follow up according to the protocol. Discussion Aim of the HASTA trial is to evaluate the efficacy of hand-suture versus stapling for closure of loop ileostomy in patients with rectal cancer. Trial registration German Clinical Trial Register Number: DRKS00000040 PMID:21303515

  11. School Closures in New York City: Did Students Do Better after Their High Schools Were Closed?

    ERIC Educational Resources Information Center

    Kemple, James J.

    2016-01-01

    Much has been written about the controversy surrounding performance-based school closures, but there has been no rigorous assessment of their impact on student achievement. Does the closure process harm students who are enrolled in a school while it is being phased out? Are future students better-off because a low-performing option has been…

  12. Treatment Strategies in 135 Consecutive Patients with Enterocutaneous Fistulas

    PubMed Central

    Visschers, Ruben G. J.; Damink, Steven W. M. Olde; Winkens, Bjorn; Soeters, Peter B.

    2008-01-01

    Background Enterocutaneous fistulas (ECF) pose a major challenge to every gastrointestinal (GI) surgeon. Based on earlier studies, a standardized treatment guideline was implemented. The focus of the present study was to assess that guideline and determine prognostic factors for outcome of patients with ECF, and to define a more detailed therapeutic approach including the convalescence time before restorative surgery. Methods All patients with ECF treated between 1990 and 2005 were included. Management consisted of controlling Sepsis, Optimization of nutritional state, Wound care, assessment of fistula Anatomy, Timing of surgery, and Surgical strategy (the SOWATS guideline). Prognostic factors were assessed by way of multiple logistic regression analysis. Results A total of 135 patients were treated at our unit. Overall closure was achieved in 118 patients (87.4%). Restorative operations for fistula closure were performed after a median of 53 days (range: 4–270 days). Restorative operations were successful in 97/107 patients (90.7%). Thirteen patients (9.6%) died. An abdominal wall defect was the most predominant negative prognostic factor for spontaneous closure (odds ratio [OR] = 0.195, confidence interval [CI] 0.052–0.726, p = 0.015). A strong relation was found between preoperative albumin level and surgical closure (p < 0.001) and mortality (p < 0.001). Conclusions Application of the SOWATS guideline allowed a favorable outcome after a short convalescence period. Abdominal wall defects and preoperative hypoalbuminemia are important prognostic variables. PMID:18175171

  13. Treatment strategies in 135 consecutive patients with enterocutaneous fistulas.

    PubMed

    Visschers, Ruben G J; Olde Damink, Steven W M; Winkens, Bjorn; Soeters, Peter B; van Gemert, Wim G

    2008-03-01

    Enterocutaneous fistulas (ECF) pose a major challenge to every gastrointestinal (GI) surgeon. Based on earlier studies, a standardized treatment guideline was implemented. The focus of the present study was to assess that guideline and determine prognostic factors for outcome of patients with ECF, and to define a more detailed therapeutic approach including the convalescence time before restorative surgery. All patients with ECF treated between 1990 and 2005 were included. Management consisted of controlling Sepsis, Optimization of nutritional state, Wound care, assessment of fistula Anatomy, Timing of surgery, and Surgical strategy (the SOWATS guideline). Prognostic factors were assessed by way of multiple logistic regression analysis. A total of 135 patients were treated at our unit. Overall closure was achieved in 118 patients (87.4%). Restorative operations for fistula closure were performed after a median of 53 days (range: 4-270 days). Restorative operations were successful in 97/107 patients (90.7%). Thirteen patients (9.6%) died. An abdominal wall defect was the most predominant negative prognostic factor for spontaneous closure (odds ratio [OR]=0.195, confidence interval [CI] 0.052-0.726, p=0.015). A strong relation was found between preoperative albumin level and surgical closure (p<0.001) and mortality (p<0.001). Application of the SOWATS guideline allowed a favorable outcome after a short convalescence period. Abdominal wall defects and preoperative hypoalbuminemia are important prognostic variables.

  14. Effectiveness of early lens extraction for the treatment of primary angle-closure glaucoma (EAGLE): a randomised controlled trial.

    PubMed

    Azuara-Blanco, Augusto; Burr, Jennifer; Ramsay, Craig; Cooper, David; Foster, Paul J; Friedman, David S; Scotland, Graham; Javanbakht, Mehdi; Cochrane, Claire; Norrie, John

    2016-10-01

    Primary angle-closure glaucoma is a leading cause of irreversible blindness worldwide. In early-stage disease, intraocular pressure is raised without visual loss. Because the crystalline lens has a major mechanistic role, lens extraction might be a useful initial treatment. From Jan 8, 2009, to Dec 28, 2011, we enrolled patients from 30 hospital eye services in five countries. Randomisation was done by a web-based application. Patients were assigned to undergo clear-lens extraction or receive standard care with laser peripheral iridotomy and topical medical treatment. Eligible patients were aged 50 years or older, did not have cataracts, and had newly diagnosed primary angle closure with intraocular pressure 30 mm Hg or greater or primary angle-closure glaucoma. The co-primary endpoints were patient-reported health status, intraocular pressure, and incremental cost-effectiveness ratio per quality-adjusted life-year gained 36 months after treatment. Analysis was by intention to treat. This study is registered, number ISRCTN44464607. Of 419 participants enrolled, 155 had primary angle closure and 263 primary angle-closure glaucoma. 208 were assigned to clear-lens extraction and 211 to standard care, of whom 351 (84%) had complete data on health status and 366 (87%) on intraocular pressure. The mean health status score (0·87 [SD 0·12]), assessed with the European Quality of Life-5 Dimensions questionnaire, was 0·052 higher (95% CI 0·015-0·088, p=0·005) and mean intraocular pressure (16·6 [SD 3·5] mm Hg) 1·18 mm Hg lower (95% CI -1·99 to -0·38, p=0·004) after clear-lens extraction than after standard care. The incremental cost-effectiveness ratio was £14 284 for initial lens extraction versus standard care. Irreversible loss of vision occurred in one participant who underwent clear-lens extraction and three who received standard care. No patients had serious adverse events. Clear-lens extraction showed greater efficacy and was more cost-effective than laser peripheral iridotomy, and should be considered as an option for first-line treatment. Medical Research Council. Copyright © 2016 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.

  15. Limited utility of preoperative studies in preparation for colostomy closure.

    PubMed

    Pokorny, R M; Heniford, T; Allen, J W; Tuckson, W B; Galandiuk, S

    1999-04-01

    Numerous diagnostic and therapeutic practices are used in an attempt to reduce the morbidity of colostomy closures. Our principal aim was to evaluate the role of preoperative studies, specifically barium enemas and endoscopic examinations, performed before colostomy closures. Additionally, we wished to identify other practices involved in the perioperative management of patients undergoing colostomy closure that influenced morbidity. The records of 100 consecutive patients who underwent elective colostomy closure at University of Louisville Hospital between January 1989 and July 1995 were reviewed. Wound infection was the most common complication (12%). Various bowel preparations were equivalent in efficacy and did not influence the complication rate. Intermittent wound irrigation with antibiotics for 3 days postoperatively, via subcutaneous drains, was associated with a low incidence of incision infection. Preoperative barium enema or sigmoidoscopy were often performed but rarely useful. Performing these examinations merely increased hospital cost without a corresponding decline in morbidity.

  16. Natural orifice transluminal endoscopic surgery gastrotomy closure with an over-the-endoscope clip: a randomized, controlled porcine study (with videos).

    PubMed

    von Renteln, Daniel; Schmidt, Arthur; Vassiliou, Melina C; Gieselmann, Maria; Caca, Karel

    2009-10-01

    Secure endoscopic closure of transgastric natural orifice transluminal endoscopic surgery (NOTES) access is of paramount importance. The over-the-scope clip (OTSC) system has previously been shown to be effective for NOTES gastrotomy closure. To compare OTSC gastrotomy closure with surgical closure. Randomized, controlled animal study. Animal facility laboratory. Thirty-six female domestic pigs. Gastrotomies were created by using a needle-knife and an 18-mm balloon. The animals were subsequently randomized to either open surgical repair with interrupted sutures or endoscopic repair with 12-mm OTSCs. In addition, pressurized leak tests were performed in ex vivo specimens of 18-mm scalpel incisions closed with suture (n = 14) and of intact stomachs (n = 10). The mean time for endoscopic closure was 9.8 minutes (range 3-22, SD 5.5). No complications occurred during either type of gastrotomy closure. At necropsy, examination of all OTSC and surgical closures demonstrated complete sealing of gastrotomy sites without evidence of injury to adjacent organs. Pressurized leak tests showed a mean burst pressure of 83 mm Hg (range 30-140, SD 27) for OTSC closures and 67 mm Hg (range 30-130, SD 27.7) for surgical sutures. Ex vivo hand-sewn sutures of 18-mm gastrotomies (n = 14) exhibited a mean burst pressure of 65 mm Hg (range 20-140, SD 31) and intact ex vivo stomachs (n = 10) had a mean burst pressure of 126 mm Hg (range 90-170, SD 28). The burst pressure of ex vivo intact stomachs was significantly higher compared with OTSC closures (P < .01), in vivo surgical closures (P < .01), and ex vivo hand-sewn closures (P < .01). There was a trend toward higher burst pressures in the OTSC closures compared with surgical closures (P = .063) and ex vivo hand-sewn closures (P = .094). In vivo surgical closures demonstrated similar burst pressures compared with ex vivo hand-sewn closures (P = .848). Nonsurvival setting. Endoscopic closure by using the OTSC system is comparable to surgical closure in a nonsurvival porcine model. This technique is easy to perform and is suitable for NOTES gastrotomy closure.

  17. 49 CFR 178.707 - Standards for composite IBCs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... materials (i.e., plastic or rubber). (3) A “rigid” inner receptacle is an inner receptacle which retains its general shape when empty without closures in place and without benefit of the outer casing. Any inner... closing is effected by gluing or taping, a water-resistant adhesive must be used. (F) All closures must be...

  18. 49 CFR 178.707 - Standards for composite IBCs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... materials (i.e., plastic or rubber). (3) A “rigid” inner receptacle is an inner receptacle which retains its general shape when empty without closures in place and without benefit of the outer casing. Any inner... closing is effected by gluing or taping, a water-resistant adhesive must be used. (F) All closures must be...

  19. 49 CFR 178.707 - Standards for composite IBCs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... materials (i.e., plastic or rubber). (3) A “rigid” inner receptacle is an inner receptacle which retains its general shape when empty without closures in place and without benefit of the outer casing. Any inner... closing is effected by gluing or taping, a water-resistant adhesive must be used. (F) All closures must be...

  20. EVALUATION OF MASS FLUX TO AND FROM GROUND WATER USING A VERTICAL FLUX MODEL (VFLUX): APPLICATION TO THE SOIL VACUUM EXTRACTION CLOSURE PROBLEM

    EPA Science Inventory

    Site closure for soil vacuum extraction (SVE) application typically requires attainment of specified soil concentration standards based on the premise that mass flux from the vadose zone to ground water not result in levels exceeding maximum contaminant levels (MCLSs). Unfortuna...

  1. Revisiting global mean sea level budget closure : Preliminary results from an integrative study within ESA's Climate Change Initiative -Sea level Budget Closure-Climate Change Initiative

    NASA Astrophysics Data System (ADS)

    Palanisamy, H.; Cazenave, A. A.

    2017-12-01

    The global mean sea level budget is revisited over two time periods: the entire altimetry era, 1993-2015 and the Argo/GRACE era, 2003-2015 using the version '0' of sea level components estimated by the SLBC-CCI teams. The SLBC-CCI is an European Space Agency's project on sea level budget closure using CCI products. Over the entire altimetry era, the sea level budget was performed as the sum of steric and mass components that include contributions from total land water storage, glaciers, ice sheets (Greenland and Antarctica) and total water vapor content. Over the Argo/GRACE era, it was performed as the sum of steric and GRACE based ocean mass. Preliminary budget analysis performed over the altimetry era (1993-2015) results in a trend value of 2.83 mm/yr. On comparison with the observed altimetry-based global mean sea level trend over the same period (3.03 ± 0.5 mm/yr), we obtain a residual of 0.2 mm/yr. In spite of a residual of 0.2 mm/yr, the sea level budget result obtained over the altimetry era is very promising as this has been performed using the version '0' of the sea level components. Furthermore, uncertainties are not yet included in this study as uncertainty estimation for each sea level component is currently underway. Over the Argo/GRACE era (2003-2015), the trend estimated from the sum of steric and GRACE ocean mass amounts to 2.63 mm/yr while that observed by satellite altimetry is 3.37 mm/yr, thereby leaving a residual of 0.7 mm/yr. Here an ensemble GRACE ocean mass data (mean of various available GRACE ocean mass data) was used for the estimation. Using individual GRACE data results in a residual range of 0.5 mm/yr -1.1 mm/yr. Investigations are under way to determine the cause of the vast difference between the observed sea level and the sea level obtained from steric and GRACE ocean mass. One main suspect is the impact of GRACE data gaps on sea level budget analysis due to lack of GRACE data over several months since 2011. The current action plan of the project is to work on an accurate closure of the sea level budget using both the above performed methodologies. We also intend to provide a standardized uncertainty estimation and to correctly identify the causes leading to sea level budget non-closure if that is the case.

  2. Corrective Action Decision Document/Corrective Action Plan for the 92-Acre Area and Corrective Action Unit 111: Area 5 WMD Retired Mixed Waste Pits, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    This Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) has been prepared for the 92-Acre Area, the southeast quadrant of the Radioactive Waste Management Site, located in Area 5 of the Nevada National Security Site (NNSS). The 92-Acre Area includes Corrective Action Unit (CAU) 111, 'Area 5 WMD Retired Mixed Waste Pits.' Data Quality Objectives (DQOs) were developed for the 92-Acre Area, which includes CAU 111. The result of the DQO process was that the 92-Acre Area is sufficiently characterized to provide the input data necessary to evaluate corrective action alternatives (CAAs) without the collection of additional data. The DQOs aremore » included as Appendix A of this document. This CADD/CAP identifies and provides the rationale for the recommended CAA for the 92-Acre Area, provides the plan for implementing the CAA, and details the post-closure plan. When approved, this CADD/CAP will supersede the existing Pit 3 (P03) Closure Plan, which was developed in accordance with Title 40 Code of Federal Regulations (CFR) Part 265, 'Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities.' This document will also serve as the Closure Plan and the Post-Closure Plan, which are required by 40 CFR 265, for the 92-Acre Area. After closure activities are complete, a request for the modification of the Resource Conservation and Recovery Act Permit that governs waste management activities at the NNSS will be submitted to the Nevada Division of Environmental Protection to incorporate the requirements for post-closure monitoring. Four CAAs, ranging from No Further Action to Clean Closure, were evaluated for the 92-Acre Area. The CAAs were evaluated on technical merit focusing on performance, reliability, feasibility, safety, and cost. Based on the evaluation of the data used to develop the conceptual site model; a review of past, current, and future operations at the site; and the detailed and comparative analysis of the potential CAAs, Closure in Place with Administrative Controls is the preferred CAA for the 92-Acre Area. Closure activities will include the following: (1) Constructing an engineered evapotranspiration cover over the 92-Acre Area; (2) Installing use restriction (UR) warning signs, concrete monuments, and subsidence survey monuments; (3) Establishing vegetation on the cover; (4) Implementing a UR; and (5) Implementing post-closure inspections and monitoring. The Closure in Place with Administrative Controls alternative meets all requirements for the technical components evaluated, fulfills all applicable federal and state regulations for closure of the site, and will minimize potential future exposure pathways to the buried waste at the site.« less

  3. Corrective Action Decision Document/Corrective Action Plan for the 92-Acre Area and Corrective Action Unit 111: Area 5 WMD Retired Mixed Waste Pits, Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2009-07-31

    This Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) has been prepared for the 92-Acre Area, the southeast quadrant of the Radioactive Waste Management Site, located in Area 5 of the Nevada Test Site (NTS). The 92-Acre Area includes Corrective Action Unit (CAU) 111, 'Area 5 WMD Retired Mixed Waste Pits.' Data Quality Objectives (DQOs) were developed for the 92-Acre Area, which includes CAU 111. The result of the DQO process was that the 92-Acre Area is sufficiently characterized to provide the input data necessary to evaluate corrective action alternatives (CAAs) without the collection of additional data. The DQOs are includedmore » as Appendix A of this document. This CADD/CAP identifies and provides the rationale for the recommended CAA for the 92-Acre Area, provides the plan for implementing the CAA, and details the post-closure plan. When approved, this CADD/CAP will supersede the existing Pit 3 (P03) Closure Plan, which was developed in accordance with Title 40 Code of Federal Regulations (CFR) Part 265, 'Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities.' This document will also serve as the Closure Plan and the Post-Closure Plan, which are required by 40 CFR 265, for the 92-Acre Area. After closure activities are complete, a request for the modification of the Resource Conservation and Recovery Act Permit that governs waste management activities at the NTS will be submitted to the Nevada Division of Environmental Protection to incorporate the requirements for post-closure monitoring. Four CAAs, ranging from No Further Action to Clean Closure, were evaluated for the 92-Acre Area. The CAAs were evaluated on technical merit focusing on performance, reliability, feasibility, safety, and cost. Based on the evaluation of the data used to develop the conceptual site model; a review of past, current, and future operations at the site; and the detailed and comparative analysis of the potential CAAs, Closure in Place with Administrative Controls is the preferred CAA for the 92-Acre Area. Closure activities will include the following: (1) Constructing an engineered evapotranspiration cover over the 92-Acre Area; (2) Installing use restriction (UR) warning signs, concrete monuments, and subsidence survey monuments; (3) Establishing vegetation on the cover; (4) Implementing a UR; and (5) Implementing post-closure inspections and monitoring. The Closure in Place with Administrative Controls alternative meets all requirements for the technical components evaluated, fulfills all applicable federal and state regulations for closure of the site, and will minimize potential future exposure pathways to the buried waste at the site.« less

  4. Validity evidence for procedural competency in virtual reality robotic simulation, establishing a credible pass/fail standard for the vaginal cuff closure procedure.

    PubMed

    Hovgaard, Lisette Hvid; Andersen, Steven Arild Wuyts; Konge, Lars; Dalsgaard, Torur; Larsen, Christian Rifbjerg

    2018-03-30

    The use of robotic surgery for minimally invasive procedures has increased considerably over the last decade. Robotic surgery has potential advantages compared to laparoscopic surgery but also requires new skills. Using virtual reality (VR) simulation to facilitate the acquisition of these new skills could potentially benefit training of robotic surgical skills and also be a crucial step in developing a robotic surgical training curriculum. The study's objective was to establish validity evidence for a simulation-based test for procedural competency for the vaginal cuff closure procedure that can be used in a future simulation-based, mastery learning training curriculum. Eleven novice gynaecological surgeons without prior robotic experience and 11 experienced gynaecological robotic surgeons (> 30 robotic procedures) were recruited. After familiarization with the VR simulator, participants completed the module 'Guided Vaginal Cuff Closure' six times. Validity evidence was investigated for 18 preselected simulator metrics. The internal consistency was assessed using Cronbach's alpha and a composite score was calculated based on metrics with significant discriminative ability between the two groups. Finally, a pass/fail standard was established using the contrasting groups' method. The experienced surgeons significantly outperformed the novice surgeons on 6 of the 18 metrics. The internal consistency was 0.58 (Cronbach's alpha). The experienced surgeons' mean composite score for all six repetitions were significantly better than the novice surgeons' (76.1 vs. 63.0, respectively, p < 0.001). A pass/fail standard of 75/100 was established. Four novice surgeons passed this standard (false positives) and three experienced surgeons failed (false negatives). Our study has gathered validity evidence for a simulation-based test for procedural robotic surgical competency in the vaginal cuff closure procedure and established a credible pass/fail standard for future proficiency-based training.

  5. 10 CFR 60.111 - Performance of the geologic repository operations area through permanent closure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Performance of the geologic repository operations area... OF HIGH-LEVEL RADIOACTIVE WASTES IN GEOLOGIC REPOSITORIES Technical Criteria Performance Objectives § 60.111 Performance of the geologic repository operations area through permanent closure. (a...

  6. Rubber closures for freeze-dried products.

    PubMed

    Hopkins, G H

    1976-10-01

    Once a biological product has been developed to perform its required medical or pharmaceutical function, it is essential that a container-closure system by chosen which will preserve the efficacy of the product up to the point of administration. The general requirements applicable to proper closure function will be reviewed and the suitability of natural and synthetic elastomers to perform these functions will be discussed. The specialized application of elastomeric materials as closures for freeze-dried products presents additional requirements which are superimposed upon those previously discussed. The first of these unique considerations relates to the proper physical design which will permit the outgassing of water vapor during the sublimation step in the lyophilizing chamber. During this outgassing the design must also permit the closure to remain affixed in the neck while only partially inserted. Since these preparations are lyophilized because they are unstable in aqueous solutions, the elastomer used must constitute an effective barrier to the transmission of moisture vapor through the closure. The MVT and gas transmission properties of elastomers will be discussed. Special consideration will be given to the extremely low temperatures used in the sublimation, stoppering, and storage before use of lyophilized products. The phenomenon of glass transition points with different elastomers will be explained as its relation to satisfactory performance of the closure function at low temperatures.

  7. Initial clinical assessment of a novel wound management system: a case series.

    PubMed

    Reyzelman, Alexander M; Vayser, Dean; Tam, S William; Dove, Cyaandi

    2011-06-01

    The importance of exudate management for maintaining local moisture balance and avoiding maceration in the chronic wound environment is well established. The authors performed the initial clinical testing of a novel wound management system, Sepaderm (Aalnex, Inc, Irvine, California), designed to vertically wick and sequester excess exudate away from wound/periwound tissues to promote a healthy wound environment. In this series of 14 patients with lower-extremity chronic venous leg and diabetic foot ulcers, the 3-component system was well tolerated and demonstrated the ability to prevent exudate leakage onto periwound tissue and reduce existing pain and itching. All ulcers lasting 1.2 to 360 months were previously treated with standard therapies, including human cell-derived skin substitutes in some of the patients. After treatment with the new system for 7 to 174 days, 8 patients had various degrees of wound closure, ranging from 44% to 100%. The 6 patients who failed to show wound closure were treated with the new system for an average of 5.7 days, but demonstrated other clinical benefits. Future studies in larger patient populations with quantitative wound closure assessments, as well as measurements of exudate, periwound maceration, and pain management, are needed.

  8. [Periprocedural and late complications after percutaneous closure of patent foramen ovale: a single centre experience].

    PubMed

    Węglarz, Przemysław; Konarska Kuszewska, Ewa; Spisak Borowska, Katarzyna; Machowski, Jerzy; Drzewiecka-Gerber, Agnieszka; Kuszewski, Piotr; Jackson, Christopher L; Opala, Grzegorz; Trusz Gluza, Maria

    2012-01-01

    Patent foramen ovale (PFO) is a potential risk factor for ischaemic stroke in young individuals. An interventional method of secondary stroke prevention in PFO patients is its percutaneous closure. To assess safety and effectiveness (i.e. lack of residual shunt) of percutaneous PFO closure in patients with history of cryptogenic cerebrovascular event. 149 patients (56 men/93 women), aged 39 ± 12 years, underwent percutaneous PFO closure. The implantation was performed under local anaesthesia, guided by trans-oesophageal echocardiography (TEE) and fluoroscopy. Follow-up trans-thoracic echocardiography (TTE) was performed at 1 month and follow-up TEE at 6-months. In cases of residual shunt, additional TEE was performed after ensuing 6 months. Effective PFO closure (no residual shunt) was achieved in 91.3% patients at 6 months and 95.3% patients at 12 months. In 2 patients transient atrial fibrillation was observed during the procedure. In 2 patients, a puncture site haematoma developed and in 1 patient superficial thrombophlebitis was noted. In 1 patient a small pericardial effusion was observed, which resolved at day 3 post-procedurally, after administration of non-steroidal anti-inflammatory drugs. Percutaneous PFO closure seems to be a safe procedure when performed in a centre with adequate expertise with regard to these procedures.

  9. Linearly exact parallel closures for slab geometry

    NASA Astrophysics Data System (ADS)

    Ji, Jeong-Young; Held, Eric D.; Jhang, Hogun

    2013-08-01

    Parallel closures are obtained by solving a linearized kinetic equation with a model collision operator using the Fourier transform method. The closures expressed in wave number space are exact for time-dependent linear problems to within the limits of the model collision operator. In the adiabatic, collisionless limit, an inverse Fourier transform is performed to obtain integral (nonlocal) parallel closures in real space; parallel heat flow and viscosity closures for density, temperature, and flow velocity equations replace Braginskii's parallel closure relations, and parallel flow velocity and heat flow closures for density and temperature equations replace Spitzer's parallel transport relations. It is verified that the closures reproduce the exact linear response function of Hammett and Perkins [Phys. Rev. Lett. 64, 3019 (1990)] for Landau damping given a temperature gradient. In contrast to their approximate closures where the vanishing viscosity coefficient numerically gives an exact response, our closures relate the heat flow and nonvanishing viscosity to temperature and flow velocity (gradients).

  10. 40 CFR 266.103 - Interim status standards for burners.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... complying with the CO controls of § 266.104(c), the CO limit is established based on the compliance test... testing planned, including a complete copy of the test protocol and Quality Assurance/Quality Control (QA...; (vi) In subpart G (Closure and post-closure), §§ 265.111-265.115; (vii) In subpart H (Financial...

  11. 40 CFR 266.103 - Interim status standards for burners.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... complying with the CO controls of § 266.104(c), the CO limit is established based on the compliance test... testing planned, including a complete copy of the test protocol and Quality Assurance/Quality Control (QA...; (vi) In subpart G (Closure and post-closure), §§ 265.111-265.115; (vii) In subpart H (Financial...

  12. 40 CFR 266.103 - Interim status standards for burners.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... complying with the CO controls of § 266.104(c), the CO limit is established based on the compliance test... testing planned, including a complete copy of the test protocol and Quality Assurance/Quality Control (QA...; (vi) In subpart G (Closure and post-closure), §§ 265.111-265.115; (vii) In subpart H (Financial...

  13. 40 CFR 266.103 - Interim status standards for burners.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... complying with the CO controls of § 266.104(c), the CO limit is established based on the compliance test... testing planned, including a complete copy of the test protocol and Quality Assurance/Quality Control (QA...; (vi) In subpart G (Closure and post-closure), §§ 265.111-265.115; (vii) In subpart H (Financial...

  14. 40 CFR 266.103 - Interim status standards for burners.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... complying with the CO controls of § 266.104(c), the CO limit is established based on the compliance test... testing planned, including a complete copy of the test protocol and Quality Assurance/Quality Control (QA...; (vi) In subpart G (Closure and post-closure), §§ 265.111-265.115; (vii) In subpart H (Financial...

  15. Is size the only determinant of delayed abdominal closure in pediatric liver transplant?

    PubMed

    Khorsandi, Shirin Elizabeth; Day, Arthur William Raven; Cortes, Miriam; Deep, Akash; Dhawan, Anil; Vilca-Melendez, Hector; Heaton, Nigel

    2017-03-01

    The aim was to determine the factors associated with the use of delayed abdominal closure in pediatric liver transplantation (LT) and whether this affected outcome. From a prospectively maintained database, transplants performed in children (≤18 years) were identified (October 2010 to March 2015). Primary abdominal closure was defined as mass closure performed at time of transplant. Delayed abdominal closure was defined as mass closure not initially performed at the same time as transplant; 230 children underwent LT. Of these, 176 (76.5%) had primary closure. Age was similar between the primary and delayed groups (5.0 ± 4.9 versus 3.9 ± 5.0 years; P = 0.13). There was no difference in the graft-to-recipient weight ratio (GRWR) in the primary and delayed groups (3.4 ± 2.8 versus 4.1 ± 2.1; P = 0.12). Children with acute liver failure (ALF) were more likely to experience delayed closure then those with chronic liver disease (CLD; P < 0.001). GRWR was similar between the ALF and CLD (3.4 ± 2.4 versus 3.6 ± 2.7; P = 0.68). Primary closure children had a shorter hospital stay (P < 0.001), spent fewer days in pediatric intensive care unit (PICU; P = 0.001), and required a shorter duration of ventilation (P < 0.001). Vascular complications (arterial and venous) were similar (primary 8.2% versus delayed 5.6%; P = 0.52). Graft (P = 0.42) and child survival (P = 0.65) in the primary and delayed groups were similar. Considering timing of mass closure after transplant, patients in the early delayed closure group (<6 weeks) were found to experience a shorter time of ventilation (P = 0.03) and in PICU (P = 0.003). In conclusion, ALF was the main determinant of delayed abdominal closure rather than GRWR. The optimal time for delayed closure is within 6 weeks. The use of delayed abdominal closure does not adversely affect graft/child survival. Liver Transplantation 23 352-360 2017 AASLD. © 2016 by the American Association for the Study of Liver Diseases.

  16. Pelvic flexure enterotomy closure in the horse with a TA-90 stapling device: A retrospective clinical study of 84 cases (2001–2008)

    PubMed Central

    Rosser, Julie; Brounts, Sabrina; Slone, Don; Lynch, Tim; Livesey, Michael; Hughes, Faith; Clark, Carol

    2012-01-01

    Our objective was to compare survival and complication rates of horses undergoing pelvic flexure enterotomy closure with a TA-90 stapler to those with hand-sewn closure. Medical records of horses undergoing pelvic flexure enterotomy between 2001 and 2008 were reviewed. History, clinical signs, surgical findings, surgical techniques, and post-operative complications were recorded. Long-term outcome was established by telephone questionnaire. Of 84 pelvic flexure enterotomies performed, 70 were stapled and 14 were hand-sewn. Seventy-seven horses survived to discharge (91.7%). There were no significant associations between survival and closure technique (P = 0.69). Follow-up was available for 54 horses; 50 survived long-term (93.0%). No statistical significance was identified between long-term survival and closure method (P = 0.39). Forty horses went on to athletic performance (80.0%). TA-90 stapled closure of pelvic flexure enterotomies is a safe technique resulting in survival and complication rates equivalent to those of hand-sewn closure. PMID:23204584

  17. Cystic Duct Closure by Sealing With Bipolar Electrocoagulation

    PubMed Central

    Damgaard, B.; Jorgensen, L. N.; Larsen, S. S.; Kristiansen, V. B.

    2010-01-01

    Background: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure®) for closure of the cystic duct. Methods: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. Results: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. Conclusion: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. PMID:20412641

  18. Mechanics of Wound Closure: Emerging Tape-Based Wound Closure Technology vs. Traditional Methods.

    PubMed

    Levi, Kemal; Ichiryu, Kei; Kefel, Pelin; Keller, Juergen; Grice, Jon; Belson, Ori; Storne, Eric; Safa, Bauback

    2016-10-12

    To date, there is still a lack of understanding of how wound closure methods perform comparatively under daily bodily movement during the course of healing and how they affect the mechanics of healing. The present study is a first step in understanding and objectively quantifying the gap. The study provides both a new method of metrology for noninvasive evaluation of skin mechanics at the onset of wound healing and an emerging tape-based wound closure technology. The latter shows better performance with respect to commonly used staples and sutures, holding the wound intact and providing uniform mechanical support across the incision.

  19. Defining Higher-Order Turbulent Moment Closures with an Artificial Neural Network and Random Forest

    NASA Astrophysics Data System (ADS)

    McGibbon, J.; Bretherton, C. S.

    2017-12-01

    Unresolved turbulent advection and clouds must be parameterized in atmospheric models. Modern higher-order closure schemes depend on analytic moment closure assumptions that diagnose higher-order moments in terms of lower-order ones. These are then tested against Large-Eddy Simulation (LES) higher-order moment relations. However, these relations may not be neatly analytic in nature. Rather than rely on an analytic higher-order moment closure, can we use machine learning on LES data itself to define a higher-order moment closure?We assess the ability of a deep artificial neural network (NN) and random forest (RF) to perform this task using a set of observationally-based LES runs from the MAGIC field campaign. By training on a subset of 12 simulations and testing on remaining simulations, we avoid over-fitting the training data.Performance of the NN and RF will be assessed and compared to the Analytic Double Gaussian 1 (ADG1) closure assumed by Cloudy Layers Unified By Binormals (CLUBB), a higher-order turbulence closure currently used in the Community Atmosphere Model (CAM). We will show that the RF outperforms the NN and the ADG1 closure for the MAGIC cases within this diagnostic framework. Progress and challenges in using a diagnostic machine learning closure within a prognostic cloud and turbulence parameterization will also be discussed.

  20. The timing of ostomy closure in infants with necrotizing enterocolitis: a systematic review.

    PubMed

    Struijs, Marie-Chantal; Sloots, Cornelius E J; Hop, Wim C J; Tibboel, Dick; Wijnen, Rene M H

    2012-07-01

    The optimal timing of ostomy closure is a matter of debate. We performed a systematic review of outcomes of early ostomy closure (EC, within 8 weeks) and late ostomy closure (LC, after 8 weeks) in infants with necrotizing enterocolitis. PubMed, EMbase, Web-of-Science, and Cinahl were searched for studies that detailed time to ostomy closure, and time to full enteral nutrition (FEN) or complications after ostomy closure. Patients with Hirschsprung's disease or anorectal malformations were excluded. Analysis was performed using SPSS 17 and RevMan 5. Of 778 retrieved articles, 5 met the inclusion criteria. The median score for study quality was 9 [range 8-14 on a scale of 0 to 32 points (Downs and Black, J Epidemiol Community Health 52:377-384, 1998)]. One study described mean time to FEN: 19.1 days after EC (n = 13) versus 7.2 days after LC (n = 24; P = 0.027). Four studies reported complication rates after ostomy closure, complications occurred in 27% of the EC group versus 23% of the LC group. The combined odds ratio (LC vs. EC) was 1.1 [95% CI 0.5, 2.5]. Evidence that supports early or late closure is scarce and the published articles are of poor quality. There is no significant difference between EC versus LC in the complication rate. This systematic review supports neither early nor late ostomy closure.

  1. A comparison of techniques for myelomeningocele defect closure in the neonatal period.

    PubMed

    Kobraei, Edward M; Ricci, Joseph A; Vasconez, Henry C; Rinker, Brian D

    2014-09-01

    Numerous techniques have been described for repair of myelomeningoceles, but outcome data is scarce. A retrospective review was performed in 32 consecutive patients who underwent neonatal myelomeningocele repair and extra-dural closure to determine the influence of repair type on outcome. All procedures for myelomeningocele closure were classified into one of three groups, which included primary closure, myocutaneous flaps, and fasciocutaneous flaps. Defect size ranged from 1 to 48 cm(2). Primary skin closure was performed in 3 patients, fasciocutaneous flaps in 13 patients, and myocutaneous flaps in 16 patients. The overall complication rate was 18%. No difference in the complication rates among the primary closure, myocutaneous, and fasciocutaneous flap groups was observed in our analysis. While not statistically significant, our data documents an association of fasciocutaneous flaps with postoperative complications that were not evident with primary skin closure or myocutaneous flaps (odds ratio 3.8; p = 0.15). The occurrence of one or more complications was associated with a longer hospital stay. Myocutaneous flaps provide a secure repair and should be considered for smaller myelomeningocele defects in addition to the larger defects where they are more traditionally used. We propose a tissue-based classification of closure techniques strictly for multi-institution outcome comparison that may ultimately inform clinical decision-making.

  2. Association of Placebo, Indomethacin, Ibuprofen, and Acetaminophen With Closure of Hemodynamically Significant Patent Ductus Arteriosus in Preterm Infants: A Systematic Review and Meta-analysis.

    PubMed

    Mitra, Souvik; Florez, Ivan D; Tamayo, Maria E; Mbuagbaw, Lawrence; Vanniyasingam, Thuva; Veroniki, Areti Angeliki; Zea, Adriana M; Zhang, Yuan; Sadeghirad, Behnam; Thabane, Lehana

    2018-03-27

    Despite increasing emphasis on conservative management of patent ductus arteriosus (PDA) in preterm infants, different pharmacotherapeutic interventions are used to treat those developing a hemodynamically significant PDA. To estimate the relative likelihood of hemodynamically significant PDA closure with common pharmacotherapeutic interventions and to compare adverse event rates. The databases of MEDLINE, Embase, and the Cochrane Central Register of Controlled Trials were searched from inception until August 15, 2015, and updated on December 31, 2017, along with conference proceedings up to December 2017. Randomized clinical trials that enrolled preterm infants with a gestational age younger than 37 weeks treated with intravenous or oral indomethacin, ibuprofen, or acetaminophen vs each other, placebo, or no treatment for a clinically or echocardiographically diagnosed hemodynamically significant PDA. Data were independently extracted in pairs by 6 reviewers and synthesized with Bayesian random-effects network meta-analyses. Primary outcome: hemodynamically significant PDA closure; secondary: included surgical closure, mortality, necrotizing enterocolitis, and intraventricular hemorrhage. In 68 randomized clinical trials of 4802 infants, 14 different variations of indomethacin, ibuprofen, or acetaminophen were used as treatment modalities. The overall PDA closure rate was 67.4% (2867 of 4256 infants). A high dose of oral ibuprofen was associated with a significantly higher odds of PDA closure vs a standard dose of intravenous ibuprofen (odds ratio [OR], 3.59; 95% credible interval [CrI], 1.64-8.17; absolute risk difference, 199 [95% CrI, 95-258] more per 1000 infants) and a standard dose of intravenous indomethacin (OR, 2.35 [95% CrI, 1.08-5.31]; absolute risk difference, 124 [95% CrI, 14-188] more per 1000 infants). Based on the ranking statistics, a high dose of oral ibuprofen ranked as the best pharmacotherapeutic option for PDA closure (mean surface under the cumulative ranking [SUCRA] curve, 0.89 [SD, 0.12]) and to prevent surgical PDA ligation (mean SUCRA, 0.98 [SD, 0.08]). There was no significant difference in the odds of mortality, necrotizing enterocolitis, or intraventricular hemorrhage with use of placebo or no treatment compared with any of the other treatment modalities. A high dose of oral ibuprofen was associated with a higher likelihood of hemodynamically significant PDA closure vs standard doses of intravenous ibuprofen or intravenous indomethacin; placebo or no treatment did not significantly change the likelihood of mortality, necrotizing enterocolitis, or intraventricular hemorrhage. PROSPERO Identifier: CRD42015015797.

  3. Neutrinoless double-β decay of 48Ca in the shell model: Closure versus nonclosure approximation

    NASA Astrophysics Data System (ADS)

    Sen'kov, R. A.; Horoi, M.

    2013-12-01

    Neutrinoless double-β decay (0νββ) is a unique process that could reveal physics beyond the Standard Model. Essential ingredients in the analysis of 0νββ rates are the associated nuclear matrix elements. Most of the approaches used to calculate these matrix elements rely on the closure approximation. Here we analyze the light neutrino-exchange matrix elements of 48Ca 0νββ decay and test the closure approximation in a shell-model approach. We calculate the 0νββ nuclear matrix elements for 48Ca using both the closure approximation and a nonclosure approach, and we estimate the uncertainties associated with the closure approximation. We demonstrate that the nonclosure approach has excellent convergence properties which allow us to avoid unmanageable computational cost. Combining the nonclosure and closure approaches we propose a new method of calculation for 0νββ decay rates which can be applied to the 0νββ decay rates of heavy nuclei, such as 76Ge or 82Se.

  4. Intra-Operative Surgical Irrigation of the Surgical Incision: What Does the Future Hold-Saline, Antibiotic Agents, or Antiseptic Agents?

    PubMed

    Edmiston, Charles E; Leaper, David J

    2016-12-01

    Intra-operative surgical site irrigation (lavage) is common practice in surgical procedures in general, with all disciplines advocating some form of irrigation before incision closure. This practice, however, has been neither standardized nor is there compelling evidence that it effectively reduces the risk of surgical site infection (SSI). This narrative review addresses the laboratory and clinical evidence that is available to support the practice of irrigation of the abdominal cavity and superficial/deep incisional tissues, using specific irrigation solutions at the end of an operative procedure to reduce the microbial burden at wound closure. Review of PubMed and OVID for pertinent, scientific, and clinical publications in the English language was performed. Incision irrigation was found to afford a three-fold benefit: First, to hydrate the bed; second, to assist in allowing better examination of the area immediately before closure; and finally, by removing superficial and deep incisional contamination and lowering the bioburden, expedite the healing process. The clinical practice of intra-operative peritoneal lavage is highly variable and is dependent solely on surgeon preference. By contrast, intra-operative irrigation after device-related procedures has become a standard of care for the prophylaxis of acute peri-prosthetic infection. The clinical evidence that supports the use of antibiotic irrigation is limited and based on retrospective analysis and few acceptable randomized controlled trials. The results of laboratory and animal studies using aqueous 0.05% chlorhexidine gluconate are favorable, suggesting that further studies are justified to determine its clinical efficacy. The adoption of appropriate and standardized intra-operative irrigation practices into peri-operative care bundles, which include other evidence-based strategies (weight-based antimicrobial prophylaxis, antimicrobial sutures, maintenance of normothermia, and glycemic control), offers an inexpensive and effective method to reduce the risk of post-operative SSI and deserves further evaluation.

  5. Effect of the application of a bundle of three measures (intraperitoneal lavage with antibiotic solution, fascial closure with Triclosan-coated sutures and Mupirocin ointment application on the skin staples) on the surgical site infection after elective laparoscopic colorectal cancer surgery.

    PubMed

    Ruiz-Tovar, Jaime; Llavero, Carolina; Morales, Vicente; Gamallo, Carlos

    2018-01-18

    Surgical site infection (SSI) prevention bundles include the simultaneous use of different measures, which individually have demonstrated an effect on prevention of SSI. The implementation of bundles can yield superior results to the implementation of individual measures. The aim of this study was to address the effect of the application of a bundle including intraperitoneal lavage with antibiotic solution, fascial closure with Triclosan-coated sutures and Mupirocin ointment application on the skin staples, on the surgical site infection after elective laparoscopic colorectal cancer surgery. A prospective, randomized study was performed, including patients with diagnosis of colorectal neoplasms and plans to undergo an elective laparoscopic surgery. The patients were randomized into two groups: those patients following standard bundles (Group 1) and those ones following the experimental bundle with three additional measures, added to the standard bundle. Incisional and organ space SSI were investigated. The study was assessor-blinded. A total of 198 patients were included in the study, 99 in each group. The incisional SSI rate was 16% in Group 1 and 2% in Group 2 [p = 0.007; RR = 5.6; CI 95% (1.4-17.8)]. The organ-space SSI rate was 4% in Group 1 and 0% in Group 2 [p = 0.039; RR = 1.7; CI 95% (1.1-11.6)]. Median hospital stay was 5.5 days in Group 1 and 4 days in Group 2 (p = 0.028). The addition of intraperitoneal lavage with antibiotic solution, fascial closure with Triclosan-coated sutures and Mupirocin ointment application on the skin staples, to a standard bundle of SSI prevention, reduces the incisional and organ-space SSI and consequently the hospital stay, after elective laparoscopic colorectal cancer surgery (ClinicalTrials.gov Identifier: NCT03081962).

  6. [Vacuum-assisted therapy for various wound types including diabetic foot ulcer].

    PubMed

    Farah, Raymond; Gantus, Maher; Kogan, Leonid

    2011-03-01

    Vacuum is a noninvasive system that creates a localized controlled negative pressure environment. In this study, vacuum was provided by the V.A.C. Therapy system, which promotes wound healing by delayed primary or secondary intention through creating a moist wound environment, preparing the wound bed for closure, reducing edema, and promoting formation and perfusion of granulation tissue. Vacuum-assisted closure therapy is indicated for use in all care settings and for a variety of wound types including diabetic foot ulcers. The purpose of this study was to evaluate safety and clinical efficacy of negative pressure wound therapy (NPWT) compared with advanced moist wound therapy and standard treatment to treat foot ulcers in diabetic patients. This trial enrolled 43 patients; most of them were diabetic patients at any age with various skin ulcers and diabetic foot. These patients were divided into two groups, 17 patients were treated with vacuum and the 26 patients in the control group were treated with standard therapy including debridement. A greater proportion of foot and skin ulcers achieved complete ulcer closure with vacuum-assisted therapy p<0.001 compared with the standard therapy. Vacuum therapy significantly decreased the duration and frequency of admission p=0.032 and decreased the rate of amputation p<0.001. Results of our trial support other studies and demonstrate that vacuum is as safe as and more efficacious than standard therapy in the treatment of diabetic foot ulcers. A significantly greater number of patients achieved complete ulcer closure and granulation tissue formation with this therapy. The study group showed a significant reduction in the median time needed to heal ulcers, reduction of the number of admissions and amputation frequency.

  7. Stapler vs suture closure of pancreatic remnant after distal pancreatectomy: a meta-analysis.

    PubMed

    Zhou, Wei; Lv, Ran; Wang, Xianfa; Mou, Yiping; Cai, Xiujun; Herr, Ingrid

    2010-10-01

    Suture closure and stapler closure of the pancreatic remnant after distal pancreatectomy are the techniques used most often. The ideal choice remains a matter of debate. Five bibliographic databases covering 1970 to July 2009 were searched. Sixteen articles met the inclusion criteria. Stapler closure was performed in 671 patients, while suture closure was conducted in 1,615 patients. The pancreatic fistula rate ranged from 0% to 40.0% for stapler closure of the pancreatic stump and from 9.3% to 45.7% for the suture closure technique. There were no significant difference between the stapler and suture closure groups with respect to the pancreatic fistula formation rate (22.1% vs 31.2%; odds ratio, .85; 95% confidence interval, .66-1.08), although there was a trend toward favoring stapler closure. In 4 studies including 437 patients, stapler closure was associated with a trend (not statistically significant) toward a reduction in intra-abdominal abscess (odds ratio, .53; 95% confidence interval, .24-1.15). No significant differences occur between suture and stapler closure with respect to the pancreatic fistula or intra-abdominal abscess after distal pancreatectomy, though there is a trend favoring stapler closure. Copyright © 2010 Elsevier Inc. All rights reserved.

  8. Procedures adopted by orthodontists for space closure and anchorage control.

    PubMed

    Monini, André da Costa; Gandini Júnior, Luiz Gonzaga; dos Santos-Pinto, Ary; Maia, Luiz Guilherme Martins; Rodrigues, Willian Caetano

    2013-01-01

    The aim of this study was to identify the procedures adopted by Brazilian orthodontists in the following situations: extraction space closure, anchorage control in case of necessary anchorage for group A and frequency of skeletal anchorage use, especially in the upper jaw. A questionnaire was sent to the e-mail address of all dentists registered in the Brazilian Federal Council of Dentistry. The results showed that most Brazilian orthodontists usually perform extraction space closure by means of sliding mechanics. The use of palatal bar, inclusion of second molars in the archwire and space closure performed in two phases are the most used techniques for anchorage control in the upper jaw. The skeletal anchorage is referenced by 36.5% of specialists as a routine practice for the upper arch anchorage. There is a wide variety of procedures adopted by Brazilian orthodontists for orthodontic space closure and anchorage control.

  9. Patent ductus arteriosus closure using Occlutech® Duct Occluder, experience in Port Elizabeth, South Africa

    PubMed Central

    Pepeta, Lungile; Greyling, Adele; Nxele, Mahlubandile Fintan; Makrexeni, Zongezile Masonwabe

    2017-01-01

    Background: Percutaneous closure of patent ductus arteriosus (PDA) has become standard therapy. Experience with the Occlutech® Duct Occluder is limited. Methods: Data regarding ductal closure using Occlutech® Duct Occluder were reviewed and prospectively collected. Demographics, hemodynamic and angiographic characteristics, complications, and outcomes were documented. Results: From March 2013 to June 2016, 65 patients (43 females and 22 males) underwent percutaneous closure of the PDA using Occlutech® Duct Occluder. The median age of the patients was 11 months (range, 1–454 months) and the median weight was 8.5 kg (range 2.5–78 kg). The mean pulmonary artery median pressure was 27 mmHg (range, 12–100 mmHg) and the QP: Qs ratio median was 1.8 (range, 1–7.5), with a pulmonary vascular resistance mean of 2.7 WU (standard deviation [SD] ±2.1). Thirty-two patients had Krichenko Type A duct (49%); 7, Type C (11%); 4, Type D (6%); and 22, Type E (34%). The ductal size (narrowest diameter at the pulmonic end) mean was 3.5 mm (SD ± 1.9 mm). The screening time mean was 17.3 min (SD ± 11.6). Out of 63 patients with successful closure of the PDA using Occlutech® Duct Occluder, there were 15 patients with small PDAs; 25 with moderate PDAs, and 23 with large PDAs. In one patient, the device dislodged to the descending aorta, and in two patients, to the right pulmonary artery immediately following deployment, with successful percutaneous (two) and surgical (one) retrieval. Complete ductal occlusion was achieved in all 63 patients on day one. Conclusion: The Occlutech® Duct Occluder is a safe and effective device for closure of ducts in appropriately selected patients. PMID:28566820

  10. Patent ductus arteriosus closure using Occlutech® Duct Occluder, experience in Port Elizabeth, South Africa.

    PubMed

    Pepeta, Lungile; Greyling, Adele; Nxele, Mahlubandile Fintan; Makrexeni, Zongezile Masonwabe

    2017-01-01

    Percutaneous closure of patent ductus arteriosus (PDA) has become standard therapy. Experience with the Occlutech® Duct Occluder is limited. Data regarding ductal closure using Occlutech® Duct Occluder were reviewed and prospectively collected. Demographics, hemodynamic and angiographic characteristics, complications, and outcomes were documented. From March 2013 to June 2016, 65 patients (43 females and 22 males) underwent percutaneous closure of the PDA using Occlutech® Duct Occluder. The median age of the patients was 11 months (range, 1-454 months) and the median weight was 8.5 kg (range 2.5-78 kg). The mean pulmonary artery median pressure was 27 mmHg (range, 12-100 mmHg) and the QP: Qs ratio median was 1.8 (range, 1-7.5), with a pulmonary vascular resistance mean of 2.7 WU (standard deviation [SD] ±2.1). Thirty-two patients had Krichenko Type A duct (49%); 7, Type C (11%); 4, Type D (6%); and 22, Type E (34%). The ductal size (narrowest diameter at the pulmonic end) mean was 3.5 mm (SD ± 1.9 mm). The screening time mean was 17.3 min (SD ± 11.6). Out of 63 patients with successful closure of the PDA using Occlutech® Duct Occluder, there were 15 patients with small PDAs; 25 with moderate PDAs, and 23 with large PDAs. In one patient, the device dislodged to the descending aorta, and in two patients, to the right pulmonary artery immediately following deployment, with successful percutaneous (two) and surgical (one) retrieval. Complete ductal occlusion was achieved in all 63 patients on day one. The Occlutech® Duct Occluder is a safe and effective device for closure of ducts in appropriately selected patients.

  11. Surgical complications associated with primary closure in patients with diabetic foot osteomyelitis

    PubMed Central

    García-Morales, Esther; Lázaro-Martínez, José Luis; Aragón-Sánchez, Javier; Cecilia-Matilla, Almudena; García-Álvarez, Yolanda; Beneit-Montesinos, Juan Vicente

    2012-01-01

    Background The aim of this study was to determine the incidence of complications associated with primary closure in surgical procedures performed for diabetic foot osteomyelitis compared to those healed by secondary intention. In addition, further evaluation of the surgical digital debridement for osteomyelitis with primary closure as an alternative to patients with digital amputation was also examined in our study. Methods Comparative study that included 46 patients with diabetic foot ulcerations. Surgical debridement of the infected bone was performed on all patients. Depending on the surgical technique used, primary surgical closure was performed on 34 patients (73.9%, Group 1) while the rest of the 12 patients were allowed to heal by secondary intention (26.1%, Group 2). During surgical intervention, bone samples were collected for both microbiological and histopathological analyses. Post-surgical complications were recorded in both groups during the recovery period. Results The average healing time was 9.9±SD 8.4 weeks in Group 1 and 19.1±SD 16.9 weeks in Group 2 (p=0.008). The percentage of complications was 61.8% in Group 1 and 58.3% in Group 2 (p=0.834). In all patients with digital ulcerations that were necessary for an amputation, a primary surgical closure was performed with successful outcomes. Discussion Primary surgical closure was not associated with a greater number of complications. Patients who received primary surgical closure had faster healing rates and experienced a lower percentage of exudation (p=0.05), edema (p<0.001) and reinfection, factors that determine the delay in wound healing and affect the prognosis of the surgical outcome. Further research with a greater number of patients is required to better define the cases for which primary surgical closure may be indicated at different levels of the diabetic foot. PMID:23050062

  12. An Optimal Parametrization of Turbulent Scales

    NASA Astrophysics Data System (ADS)

    Thalabard, S.

    2015-12-01

    To numerically capture the large-scale dynamics of atmospheric flows, geophysicists need to rely on reasonable parametrizations of the energy transfers to and from the non-resolved small scale eddies, mediated through turbulence. The task is notoriously not trivial, and is typically solved by ingenious but ad-hoc elaborations on the concept of eddy viscosities. The difficulty is tied into the intrinsic Non-Gaussianity of turbulence, a feature that may explain why standard Quasi-Normal cumulant discard statistical closure strategies can fail dramatically, an example being the development of negative energy spectra in Millionshtchikov's 1941 Quasi-Normal (QN) theory. While Orszag's 1977 Eddy Damped Quasi Normal Markovian closure (EDQNM) provides an ingenious patch to the issue, the reason why the QN theory fails so badly is not so clear. Are closures necessarily either trivial or ad-hoc, when proxies for true ensemble averages are taken to be Gaussian ? The purpose of the talk is to answer negatively, using the lights of a new ``optimal closure framework'' recently exposed by [Turkington,2013]. For turbulence problems, the optimal closure allows a consistent use of a Gaussian Ansatz (and corresponding vanishing third cumulant) that also retains an intrinsic damping. The key to this apparent paradox lies in a clear distinction between the true ensemble averages and their proxies, most easily grasped provided one uses the Liouville equation as a starting point, rather than the cumulant hierarchy. Schematically said, closure is achieved by minimizing a lack-of-fit residual, which retains the intrinsic features of the true dynamics. The optimal closure is not restricted to the Gaussian modeling. Yet, for the sake of clarity, I will discuss the optimal closure on a problem where it can be entirely implemented, and compared to DNS : the relaxation of an arbitrarily far from equilibrium energy shell towards the Gibbs equilibrium for truncated Euler dynamics. Predictive insights are obtained, among which a non-trivial universal relaxation profile for the inverse temperatures (see associated figure). It is associated to a non-standard dissipation operator responsible for the turbulent damping, possibly relevant for atmospheric dynamics.

  13. Refined annotation and assembly of the Tetrahymena thermophila genome sequence through EST analysis, comparative genomic hybridization, and targeted gap closure

    PubMed Central

    Coyne, Robert S; Thiagarajan, Mathangi; Jones, Kristie M; Wortman, Jennifer R; Tallon, Luke J; Haas, Brian J; Cassidy-Hanley, Donna M; Wiley, Emily A; Smith, Joshua J; Collins, Kathleen; Lee, Suzanne R; Couvillion, Mary T; Liu, Yifan; Garg, Jyoti; Pearlman, Ronald E; Hamilton, Eileen P; Orias, Eduardo; Eisen, Jonathan A; Methé, Barbara A

    2008-01-01

    Background Tetrahymena thermophila, a widely studied model for cellular and molecular biology, is a binucleated single-celled organism with a germline micronucleus (MIC) and somatic macronucleus (MAC). The recent draft MAC genome assembly revealed low sequence repetitiveness, a result of the epigenetic removal of invasive DNA elements found only in the MIC genome. Such low repetitiveness makes complete closure of the MAC genome a feasible goal, which to achieve would require standard closure methods as well as removal of minor MIC contamination of the MAC genome assembly. Highly accurate preliminary annotation of Tetrahymena's coding potential was hindered by the lack of both comparative genomic sequence information from close relatives and significant amounts of cDNA evidence, thus limiting the value of the genomic information and also leaving unanswered certain questions, such as the frequency of alternative splicing. Results We addressed the problem of MIC contamination using comparative genomic hybridization with purified MIC and MAC DNA probes against a whole genome oligonucleotide microarray, allowing the identification of 763 genome scaffolds likely to contain MIC-limited DNA sequences. We also employed standard genome closure methods to essentially finish over 60% of the MAC genome. For the improvement of annotation, we have sequenced and analyzed over 60,000 verified EST reads from a variety of cellular growth and development conditions. Using this EST evidence, a combination of automated and manual reannotation efforts led to updates that affect 16% of the current protein-coding gene models. By comparing EST abundance, many genes showing apparent differential expression between these conditions were identified. Rare instances of alternative splicing and uses of the non-standard amino acid selenocysteine were also identified. Conclusion We report here significant progress in genome closure and reannotation of Tetrahymena thermophila. Our experience to date suggests that complete closure of the MAC genome is attainable. Using the new EST evidence, automated and manual curation has resulted in substantial improvements to the over 24,000 gene models, which will be valuable to researchers studying this model organism as well as for comparative genomics purposes. PMID:19036158

  14. Differences in Mathematical Performance, Creativity Potential, and Need for Cognitive Closure between Chinese and Australian Students

    ERIC Educational Resources Information Center

    Ma, Choi-Chi Evelene; Rapee, Ronald M.

    2015-01-01

    Research has shown that Chinese students outperform students from several Western countries on mathematics performance while some evidence has suggested that Western students perform more strongly on tests of creativity. One potential mechanism for these differences may be a higher need for cognitive closure among Chinese students. The current…

  15. Neutrinoless double-β decay of Se82 in the shell model: Beyond the closure approximation

    NASA Astrophysics Data System (ADS)

    Sen'kov, R. A.; Horoi, M.; Brown, B. A.

    2014-05-01

    We recently proposed a method [R. A. Senkov and M. Horoi, Phys. Rev. C 88, 064312 (2013), 10.1103/PhysRevC.88.064312] to calculate the standard nuclear matrix elements for neutrinoless double-β decay (0νββ) of Ca48 going beyond the closure approximation. Here we extend this analysis to the important case of Se82, which was chosen as the base isotope for the upcoming SuperNEMO experiment. We demonstrate that by using a mixed method that considers information from closure and nonclosure approaches, one can get excellent convergence properties for the nuclear matrix elements, which allows one to avoid unmanageable computational costs. We show that in contrast with the closure approximation the mixed approach has a very weak dependence on the average closure energy. The matrix elements for the heavy neutrino-exchange mechanism that could contribute to the 0νββ decay of Se82 are also presented.

  16. 10 CFR 61.44 - Stability of the disposal site after closure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Stability of the disposal site after closure. 61.44 Section 61.44 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Performance Objectives § 61.44 Stability of the disposal site after closure. The disposal...

  17. 10 CFR 61.44 - Stability of the disposal site after closure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Stability of the disposal site after closure. 61.44 Section 61.44 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Performance Objectives § 61.44 Stability of the disposal site after closure. The disposal...

  18. 10 CFR 61.44 - Stability of the disposal site after closure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Stability of the disposal site after closure. 61.44 Section 61.44 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Performance Objectives § 61.44 Stability of the disposal site after closure. The disposal...

  19. 10 CFR 61.44 - Stability of the disposal site after closure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Stability of the disposal site after closure. 61.44 Section 61.44 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Performance Objectives § 61.44 Stability of the disposal site after closure. The disposal...

  20. 10 CFR 61.44 - Stability of the disposal site after closure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Stability of the disposal site after closure. 61.44 Section 61.44 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Performance Objectives § 61.44 Stability of the disposal site after closure. The disposal...

  1. [Velopharyngeal closure pattern and speech performance among submucous cleft palate patients].

    PubMed

    Heng, Yin; Chunli, Guo; Bing, Shi; Yang, Li; Jingtao, Li

    2017-06-01

    To characterize the velopharyngeal closure patterns and speech performance among submucous cleft palate patients. Patients with submucous cleft palate visiting the Department of Cleft Lip and Palate Surgery, West China Hospital of Stomatology, Sichuan University between 2008 and 2016 were reviewed. Outcomes of subjective speech evaluation including velopharyngeal function, consonant articulation, and objective nasopharyngeal endoscopy including the mobility of soft palate, pharyngeal walls were retrospectively analyzed. A total of 353 cases were retrieved in this study, among which 138 (39.09%) demonstrated velopharyngeal competence, 176 (49.86%) velopharyngeal incompetence, and 39 (11.05%) marginal velopharyngeal incompetence. A total of 268 cases were subjected to nasopharyngeal endoscopy examination, where 167 (62.31%) demonstrated circular closure pattern, 89 (33.21%) coronal pattern, and 12 (4.48%) sagittal pattern. Passavant's ridge existed in 45.51% (76/167) patients with circular closure and 13.48% (12/89) patients with coronal closure. Among the 353 patients included in this study, 137 (38.81%) presented normal articulation, 124 (35.13%) consonant elimination, 51 (14.45%) compensatory articulation, 36 (10.20%) consonant weakening, 25 (7.08%) consonant replacement, and 36 (10.20%) multiple articulation errors. Circular closure was the most prevalent velopharyngeal closure pattern among patients with submucous cleft palate, and high-pressure consonant deletion was the most common articulation abnormality. Articulation error occurred more frequently among patients with a low velopharyngeal closure rate.

  2. Closure of a Recurrent Bronchopleural Fistula Using a Matrix Seeded With Patient-Derived Mesenchymal Stem Cells.

    PubMed

    Aho, Johnathon M; Dietz, Allan B; Radel, Darcie J; Butler, Greg W; Thomas, Mathew; Nelson, Timothy J; Carlsen, Brian T; Cassivi, Stephen D; Resch, Zachary T; Faubion, William A; Wigle, Dennis A

    2016-10-01

    : Management of recurrent bronchopleural fistula (BPF) after pneumonectomy remains a challenge. Although a variety of devices and techniques have been described, definitive management usually involves closure of the fistula tract through surgical intervention. Standard surgical approaches for BPF incur significant morbidity and mortality and are not reliably or uniformly successful. We describe the first-in-human application of an autologous mesenchymal stem cell (MSC)-seeded matrix graft to repair a multiply recurrent postpneumonectomy BPF. Adipose-derived MSCs were isolated from patient abdominal adipose tissue, expanded, and seeded onto bio-absorbable mesh, which was surgically implanted at the site of BPF. Clinical follow-up and postprocedural radiological and bronchoscopic imaging were performed to ensure BPF closure, and in vitro stemness characterization of patient-specific MSCs was performed. The patient remained clinically asymptomatic without evidence of recurrence on bronchoscopy at 3 months, computed tomographic imaging at 16 months, and clinical follow-up of 1.5 years. There is no evidence of malignant degeneration of MSC populations in situ, and the patient-derived MSCs were capable of differentiating into adipocytes, chondrocytes, and osteocytes using established protocols. Isolation and expansion of autologous MSCs derived from patients in a malnourished, deconditioned state is possible. Successful closure and safety data for this approach suggest the potential for an expanded study of the role of autologous MSCs in regenerative surgical applications for BPF. Bronchopleural fistula is a severe complication of pulmonary resection. Current management is not reliably successful. This work describes the first-in-human application of an autologous mesenchymal stem cell (MSC)-seeded matrix graft to the repair of a large, multiply recurrent postpneumonectomy BPF. Clinical follow-up of 1.5 years without recurrence suggests initial safety and feasibility of this approach. Further assessment of MSC grafts in these difficult clinical scenarios requires expanded study. ©AlphaMed Press.

  3. Contact behaviour of children and parental employment behaviour during school closures against the pandemic influenza A (H1N1-2009) in Japan.

    PubMed

    Mizumoto, Kenji; Yamamoto, Taro; Nishiura, Hiroshi

    2013-06-01

    To identify epidemiological determinants of the contact behaviour of children and their impact on parental employment, during school closures that took place over the course of the 2009 pandemic influenza (H1N1-2009) in Japan. A retrospective survey was conducted in Japanese households between October 2009 and May 2010 by administration of a standardized questionnaire. Demographic and behavioural variables were explored, in association with the frequency with which children left the home and the risk of parents being absent from work during school closures. Data from 882 eligible households were analysed. A total of 181/882 (20.5%) of households reported that children left the home for nonessential reasons during school closures. No impact on parental working hours was reported by 742/882 (84.1%) of households. Univariate analyses showed that the frequency with which children left the home was dependent on age, extent of school closure and requirement for special childcare arrangements. A greater understanding of age-dependent behaviours, during school closures as a consequence of a pandemic, is required. Consideration of a public policy to permit a paid leave of absence from work for parents during school closures may be beneficial; the cost-effectiveness of such a measure should be assessed in future.

  4. Standardized laryngeal videostroboscopic rating: differences between untrained and trained male and female subjects, and effects of varying sound intensity, fundamental frequency, and age.

    PubMed

    Sulter, A M; Schutte, H K; Miller, D G

    1996-06-01

    To determine the influence of the factors gender, vocal training, sound intensity, pitch, and aging on vocal function, videolaryngostroboscopic images of 214 subjects, subdivided according to gender and status of vocal training, were evaluated by three judges with standardized rating scales, comprising aspects of laryngeal appearance (larynx/pharynx ratio; epiglottal shape; asymmetry arytenoid region; compensatory adjustments; thickness, width, length, and elasticity of vocal folds) and glottal functioning (amplitudes of excursion; duration, percentage, and type of vocal fold closure; phase differences; location of glottal chink). The video registrations were made while the subjects performed a set of phonatory tasks, comprising the utterance of the vowel /i/ at three levels of both fundamental frequency and sound intensity. Analysis of the rating scales showed generally sufficient agreement among judges. With the exception of more frequently observed complete closure and lateral phase differences of vocal fold excursions in trained subjects, no further differences were established between untrained and trained subjects. With an alpha level of p = 0.005, men differed from women with respect to laryngeal appearance (larynx/pharynx ratio, compensatory adjustments, and the presence of omega and deviant-shaped epiglottises), and their vocal folds were rated thicker in the vertical dimension, smaller in the lateral dimension, longer, and more tense, with smaller amplitudes of excursion during vibration. Glottal closure in male subjects was rated more complete, but briefer in duration. Significant effects of the factors pitch, sound intensity, and age on vocal fold appearance and glottal functioning were ascertained. Awareness of the influence of these factors, as well as the factor gender, on the rated scales is essential for an adequate evaluation of laryngostroboscopic images.

  5. Quality of life of ulcerative colitis patients treated surgically with proctocolectomy and J-pouch formation: a comparative study before surgery and after closure of the defunctioning ileostomy.

    PubMed

    Exarchos, Georgios; Gklavas, Antonios; Metaxa, Linda; Papaconstantinou, Ioannis

    2018-01-01

    Ulcerative colitis (UC) is a lifelong disease with a relapse-remission pattern that affects patients' social and psychological wellbeing. Restorative proctocolectomy and J-pouch formation is the gold-standard surgical procedure in cases where symptoms are refractory to currently available medical treatment. The aim of this study was to assess patients' quality of life (QoL) in order to evaluate the efficiency of surgery and patients' symptomatology. We performed a prospective comparative study of the QoL of 47 patients with UC, treated surgically. As research tools, we used the Inflammatory Bowel Disease Questionnaire (IBDQ) and the Cleveland Global Quality of Life (CGQL) questionnaire. Parametric and non-parametric tests were used in order to correlate areas of QoL and other selected factors, such as marital status, sex, age, and education. The mean scores before and after closure of the ileostomy were 153.29 and 178 for the IBDQ (P=0.0025), and 17.4 and 23.42 for the CGQL (P<0.001), suggesting an overall improvement in QoL. The research showed that there was no specific QoL factor, such as intestinal, systemic, emotional or social life symptoms, that improved significantly more than the others (P=0.99). The IBDQ showed that patients aged less than 20 years (P<0.001), female patients (P=0.03) and patients with secondary education (P<0.001) reported the greatest improvement. The QoL in UC patients treated surgically improved following closure of the de-functioning ileostomy. QoL studies are encouraged to optimize and maintain high standards of surgical care, and they could potentially be used for assessment of therapeutic efficacy.

  6. Management of hidradenitis suppurativa wounds with an internal vacuum-assisted closure device.

    PubMed

    Chen, Y Erin; Gerstle, Theodore; Verma, Kapil; Treiser, Matthew D; Kimball, Alexandra B; Orgill, Dennis P

    2014-03-01

    Hidradenitis suppurativa is a chronic, debilitating disease that is difficult to treat. Once medical management fails, wide local excision offers the best chance for cure. However, the resultant wound often proves too large or contaminated for immediate closure. The authors performed a retrospective chart review of hidradenitis cases managed surgically between 2005 and 2010. Data collected included patient characteristics, management method, and outcomes. Approximately half of the patients received internal vacuum-assisted closure therapy using the vacuum-assisted closure system and delayed closure and half of the patients received immediate primary closure at the time of their excision. Delayed closure consisted of closing the majority of the wound in a linear fashion following internal vacuum-assisted closure while accepting healing by means of secondary intention for small wound areas. Patients managed with internal vacuum-assisted closure had wounds on average four times larger in area than patients managed without internal vacuum-assisted closure. In both groups, all wounds were eventually closed primarily. Healing times averaged 2.2 months with internal vacuum-assisted closure and 2.7 months without. At an average follow-up time of 2.3 months, all patients with internal vacuum-assisted closure had no recurrence of their local disease. Severe hidradenitis presents a treatment challenge, as surgical excisions are often complicated by difficult closures and unsatisfactory recurrence rates. This study demonstrates that wide local excision with reasonable outcomes can be achieved using accelerated delayed primary closure. This method uses internal vacuum-assisted closure as a bridge between excision and delayed primary closure, facilitating closure without recurrence in large, heavily contaminated wounds. Therapeutic, III.

  7. In vitro comparison of intra-abdominal hypertension development after different temporary abdominal closure techniques.

    PubMed

    Benninger, Emanuel; Labler, Ludwig; Seifert, Burkhardt; Trentz, Otmar; Menger, Michael D; Meier, Christoph

    2008-01-01

    To compare volume reserve capacity (VRC) and development of intra-abdominal hypertension after different in vitro temporary abdominal closure (TAC) techniques. A model of the abdomen was designed. The abdominal wall was simulated with polychloroprene, a synthetic rubber compound. A lentil-shaped defect of 150 cm(2) was cut into the anterior aspect of the abdominal wall. TAC of this defect was performed by a zipper system (ZS), a bag silo closure (BSC), or a vacuum assisted closure (VAC) with subatmospheric pressures ranging from 0- to 200 mmHg. The model with intact abdominal wall served as reference. The model was filled with water to baseline level. The intra-abdominal pressure was increased in 2 mmHg steps from baseline level (6 mmHg) to 40 mmHg by adding volume to the system according to a standardized protocol. VRC with corresponding intra-abdominal pressure were analyzed and compared for the different TAC techniques. VRC was the highest after BSC at all pressure levels studied (P < 0.05). VAC and ZS resulted in significantly lower VRC compared with BSC and reference (P < 0.05). The magnitude of negative pressure on the VAC did not significantly influence the VRC. In the present in vitro model, BSC demonstrated the highest VRC of all evaluated TAC techniques. Different levels of subatmospheric pressures applied to the VAC did not affect VRC. The results for ZS and VAC indicate that these TAC techniques may increase the risk for recurrent intra-abdominal hypertension and should therefore not be used in high-risk patients during the initial phase after abdominal decompression.

  8. Hidden (end-on) patent ductus arteriosus: recognition and device closure.

    PubMed

    Garg, Naveen; Madan, Bevunahalli Kantharaj

    2016-02-01

    Sometimes, it is difficult to visualize a patent ductus arteriosus and deploy a device in the standard lateral view because of an end-on orientation. The right anterior oblique view may be helpful by separating the ductus arteriosus from the aorta. This study was undertaken to evaluate the incidence of end-on patent ductus arteriosus and the utility of the right anterior oblique view during device closure. Aortography was performed in lateral and right anterior oblique views before, during, and after successful device deployment in 117 consecutive patients. When a ductus arteriosus was not clearly visible in the lateral view due to overlapping by the aorta, it was termed "right anterior oblique view useful". The types of patent ductus arteriosus were A, B, C, and E in 86 (73.5%), 20 (17.1%), 4 (3.4%), and 7 (6.0%) patients, respectively. An end-on ductus arteriosus was present in 24 (20.5%) patients (14 type B, 10 type A). The right anterior oblique view was useful during device closure in 15 (12.8%) cases (all end-on type). Among all cases of end-on patent ductus arteriosus, it was useful in 62.5% (most type B and a few type A). In all of these, the device appeared obliquely oriented and foreshortened in the lateral view but fully profiled in the right anterior oblique view. Recognizing an end-on patent ductus arteriosus and utilizing the right anterior oblique view simplified device closure. For ducts well-profiled in the lateral view, the right anterior oblique view is unnecessary and avoidable. © The Author(s) 2016.

  9. Morphologic changes of the anal sphincter musculature during and after temporary stool deviation.

    PubMed

    Sailer, M; Fein, M; Fuchs, K H; Bussen, D; Grun, C; Thiede, A

    2001-04-01

    Temporary stool deviation, using a stoma, is a well-known surgical principle to protect low colorectal or coloanal anastomoses. The purpose of this study was to evaluate any morphologic changes with regard to the anal sphincter muscles during and after temporary ileostomy. Forty-four patients with rectal carcinomas were studied prospectively. All patients underwent low anterior resection. Reconstruction was performed using either a coloanal pouch or a straight end-to-end anastomosis. A protective stoma was fashioned in all 44 patients (ileostomy n=41; colostomy n=3). Stoma closure was carried out after a median of 85 days (41-330 days). Using a standard protocol, anal-sphincter thickness [m. puborectalis, external anal sphincter (EAS) and internal anal (IAS) sphincter] was assessed by means of endoanal ultrasonography preoperatively, at the time of stoma closure, and every 3 months thereafter for 1 year. The diameter of the puborectal muscle decreased from a median preoperative value of 6.3 mm to 5.7 mm at the time of stoma closure (P=0.03). After 3 months, 6.2 mm was measured. This value remained stable for the complete follow-up period. Similar results were recorded for the EAS. The IAS thickness remained stable throughout the study period, measuring between 2.1 mm and 2.4 mm. Temporary stool deviation does lead to morphologic changes of the anal sphincter. While the smooth muscle remains unchanged, the striated counterpart undergoes atrophic transformation. However, after passage reconstruction, i.e., stoma closure, a rapid regeneration of the voluntary muscles is observed.

  10. 10 CFR 63.111 - Performance objectives for the geologic repository operations area through permanent closure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Performance objectives for the geologic repository... (CONTINUED) DISPOSAL OF HIGH-LEVEL RADIOACTIVE WASTES IN A GEOLOGIC REPOSITORY AT YUCCA MOUNTAIN, NEVADA... repository operations area through permanent closure. (a) Protection against radiation exposures and releases...

  11. Effect of abdominal negative-pressure wound therapy on the measurement of intra-abdominal pressure.

    PubMed

    García, Alberto Federico; Sánchez, Álvaro Ignacio; Gutiérrez, Álvaro José; Bayona, Juan Gabriel; Naranjo, María Paula; Lago, Sebastián; Puyana, Juan Carlos

    2018-07-01

    In critically ill surgical patients undergoing abdominal negative-pressure wound therapy (NPWT), it remains uncertain whether or not intra-abdominal pressure (IAP) measurements should be obtained when NPWT is activated. We aimed to determine agreement between IAP measured with and without NPWT. In this analytic cross-sectional study, critically ill surgical adults (≥18 y) requiring abdominal NPWT for temporary abdominal closure after a damage control laparotomy were selected. Patients with urinary tract injuries or with pelvic packing were excluded. Paired IAP measures were performed in the same patient, with and without NPWT; two different operators performed the measures unaware of the other's result. Bland-Altman methods assessed the agreement between the two measures. Subgroup analyses (trauma and nontrauma) were performed. There were 198 IAP measures (99 pairs) in 38 patients. Mean IAP with and without NPWT were 8.33 (standard deviation 4.01) and 8.65 (standard deviation 4.04), respectively. Mean IAP difference was -0.323 (95% confidence interval -0.748 to 0.101), and reference range for difference was -4.579 to 3.932 (P = 0.864). From 112 IAP measures (56 pairs) in 21 trauma patients, mean IAP difference was -0.268 (95% confidence interval -0.867 to 0.331), and reference range for the difference was -4.740 to 4.204 (P = 0.427). There was no statistically significant disagreement in IAP measures. IAP could be measured with or without NPWT. In critically ill surgical patients with abdominal NPWT for temporary abdominal closure, monitoring and management of IAP either with or without NPWT is recommended. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Prophylactic Mesh Reinforcement versus Sutured Closure to Prevent Incisional Hernias after Open Abdominal Aortic Aneurysm Repair via Midline Laparotomy: A Systematic Review and Meta-Analysis.

    PubMed

    Indrakusuma, Reza; Jalalzadeh, Hamid; van der Meij, Jessica E; Balm, Ron; Koelemay, Mark J W

    2018-04-20

    Incisional hernia is a frequent late complication after open abdominal aortic aneurysm (AAA) repair. We aimed to determine whether prophylactic mesh reinforcement of the abdominal wall at open AAA repair via midline laparotomy reduces the rate of incisional hernia compared to standard sutured closure. A systematic review and meta-analysis was carried out in accordance with the PRISMA statement (PROSPERO registration CRD42017072508). Randomised controlled trials (RCTs) comparing prophylactic mesh reinforcement with standard sutured closure were eligible for inclusion. MEDLINE, Embase, and the Cochrane Library were searched. A meta-analysis with a random effects model was carried out to estimate pooled risk ratios (RR) with 95% confidence intervals (CIs) for the incidence of, and re-operation rate for, incisional hernias. Assessments of methodological quality, quality of evidence, and strength of recommendations were done with the Cochrane Collaboration's tool for assessing risk of bias and the GRADE approach. Four RCTs with a total of 388 patients were included in the meta-analysis. Pooled analysis showed that mesh reinforcement significantly reduced the risk of incisional hernia after AAA repair compared with standard sutured closure (RR 0.27, 95% CI 0.11-0.66). The pooled rate of re-operations was not different between groups (RR 0.23, 95% CI 0.11-1.05). Mesh reinforcement did not cause more intra-operative or post-operative complications than sutured closure. The risk of bias in studies was low and the quality of evidence was rated as moderate. Prophylactic mesh reinforcement of the abdominal wall after open AAA repair via midline laparotomy significantly reduces the risk of incisional hernia. However, no significant difference in re-operation for incisional hernia was found. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  13. Groundwater quality assessment plan for single-shell waste management area B-BX-BY at the Hanford Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SM Narbutovskih

    2000-03-31

    Pacific Northwest National Laboratory conducted a first determination groundwater quality assessment at the Hanford Site. This work was performed for the US Department of Energy, Richland Operations Office, in accordance with the Federal Facility Compliance Agreement during the time period 1996--1998. The purpose of the assessment was to determine if waste from the Single-Shell Tank (SST) Waste Management Area (WMA) B-BX-BY had entered the groundwater at levels above the drinking water standards (DWS). The resulting assessment report documented evidence demonstrating that waste from the WMA has, most likely, impacted groundwater quality. Based on 40 CFR 265.93 [d] paragraph (7), themore » owner-operator must continue to make the minimum required determinations of contaminant level and of rate/extent of migrations on a quarterly basis until final facility closure. These continued determinations are required because the groundwater quality assessment was implemented prior to final closure of the facility.« less

  14. Closure Report for Corrective Action Unit 139: Waste Disposal Sites, Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2009-07-31

    Corrective Action Unit (CAU) 139 is identified in the Federal Facility Agreement and Consent Order (FFACO) as 'Waste Disposal Sites' and consists of the following seven Corrective Action Sites (CASs), located in Areas 3, 4, 6, and 9 of the Nevada Test Site: CAS 03-35-01, Burn Pit; CAS 04-08-02, Waste Disposal Site; CAS 04-99-01, Contaminated Surface Debris; CAS 06-19-02, Waste Disposal Site/Burn Pit; CAS 06-19-03, Waste Disposal Trenches; CAS 09-23-01, Area 9 Gravel Gertie; and CAS 09-34-01, Underground Detection Station. Closure activities were conducted from December 2008 to April 2009 according to the FFACO (1996, as amended February 2008) andmore » the Corrective Action Plan for CAU 139 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2007b). The corrective action alternatives included No Further Action, Clean Closure, and Closure in Place with Administrative Controls. Closure activities are summarized. CAU 139, 'Waste Disposal Sites,' consists of seven CASs in Areas 3, 4, 6, and 9 of the NTS. The closure alternatives included No Further Action, Clean Closure, and Closure in Place with Administrative Controls. This CR provides a summary of completed closure activities, documentation of waste disposal, and confirmation that remediation goals were met. The following site closure activities were performed at CAU 139 as documented in this CR: (1) At CAS 03-35-01, Burn Pit, soil and debris were removed and disposed as LLW, and debris was removed and disposed as sanitary waste. (2) At CAS 04-08-02, Waste Disposal Site, an administrative UR was implemented. No postings or post-closure monitoring are required. (3) At CAS 04-99-01, Contaminated Surface Debris, soil and debris were removed and disposed as LLW, and debris was removed and disposed as sanitary waste. (4) At CAS 06-19-02, Waste Disposal Site/Burn Pit, no work was performed. (5) At CAS 06-19-03, Waste Disposal Trenches, a native soil cover was installed, and a UR was implemented. (6) At CAS 09-23-01, Area 9 Gravel Gertie, a UR was implemented. (7) At CAS 09-34-01, Underground Detection Station, no work was performed.« less

  15. Late Closure of a Stage III Idiopathic Macular Hole after Pars Plana Vitrectomy.

    PubMed

    Afrashi, Filiz; Öztaş, Zafer; Nalçacı, Serhad

    2015-12-01

    A 57-year-old female presented to our hospital with decreased vision in her right eye. Detailed ocular examination was performed, and a macular hole was detected in the right eye. The presence of a full-thickness stage III macular hole was confirmed with optical coherence tomography (OCT) imaging. Pars plana vitrectomy followed by long-acting gas tamponade (C3F8) was performed as treatment. One month after surgery, clinical examination revealed a persistent macular hole, confirmed by an OCT scan. Although the patient was scheduled for reoperation, the surgery was postponed due to personal reasons of the patient. Surprisingly, after five months, a closure pattern with accompanying epiretinal membrane was observed in the macular hole area. The closure of the macular hole was completed without any further intervention 8 months post-surgery. In cases of unclosed macular hole after the first surgery, if a second surgery cannot be performed, follow-up with OCT recommended due to the possibility of spontaneous closure. However, spontaneous closure of a persistent macular hole following PPV is rare, so early diagnosis and surgical repair of unclosed macular holes must remain the primary goal.

  16. Adjunctive treatment of abdominal catastrophes and sepsis with direct peritoneal resuscitation: indications for use in acute care surgery.

    PubMed

    Smith, Jason W; Neal Garrison, R; Matheson, Paul J; Harbrecht, Brian G; Benns, Matthew V; Franklin, Glen A; Miller, Keith R; Bozeman, Matthew C; David Richardson, J

    2014-09-01

    The success of damage-control surgery (DCS) for the treatment of trauma has led to its use in other surgical problems such as abdominal sepsis. Previous studies using direct peritoneal resuscitation (DPR) for the treatment of trauma have yielded promising results. We present the results of the application of this technique to patients experiencing abdominal sepsis. We enrolled 88 DCS patients during a 5 year-period (January 2008 to December 2012) into a propensity-matched study to evaluate the utility of using DPR in addition to standard resuscitation. DPR consisted of peritoneal lavage with 2.5% DELFLEX, and abdominal closure was standardized across both groups. Patients were matched using Acute Physiology and Chronic Health Evaluation II (APACHE II) variables. Univariate and multivariate analyses were performed. There were no differences between the control and experimental groups with regard to age, sex, ethnicity, or APACHE II at 24 hours. Indications for damage control included pancreatitis, perforated hollow viscous, bowel obstruction, and ischemic enterocolitis. Patients undergoing DPR had both a higher rate of (68% vs. 43%, p < 0.03) and a shorter time to definitive fascial closure (5.9 [3.2] days vs. 7.7 [4.1] days, p < 0.02). DPR patients had a decreased APACHE II and Sequential Organ Failure Assessment (SOFA) score compared with the controls at 48 hours. In addition, DPR patients had fewer abdominal complications compared with the controls (RR, 0.57; 95% confidence interval, 0.32-1.01; p = 0.038). Ventilator days and intensive care unit length of stay were both significantly reduced in the DPR group. The DPR group showed a lower overall mortality at 30 days (16% vs. 27%, p = 0.15). DPR reduces time to definitive abdominal closure, increases primary fascial closure, and reduces intra-abdominal complications following DCS. DPR may also attenuate progressive physiologic injury as demonstrated by a reduction in 48-hour intensive care unit severity scores. As a result, DPR following DCS may afford better outcomes to patients experiencing shock. Therapeutic study, level III.

  17. 3013 DE INNER CONTAINER CLOSURE WELD CORROSION EVALUATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mickalonis, J.

    Destructive evaluation (DE) of 3013 containers is one part of the U. S. Department of Energy Integrated Surveillance Program. During standard DE of 3013 containers, visual examinations for pitting and stress corrosion cracking (SCC) are performed on the accessible surfaces of the outer, inner, and convenience containers, which make up the 3013 container. As a result of 3013 DE additional analysis, the area near the inner container closure weld has been identified as being a region of increased corrosion susceptibility, which may provide a pathway for corrosive gases to the outer container. This area has a higher residual stress, anmore » altered microstructure, and less corrosion resistant weld oxides as a result of the welding process as well as a lower temperature than other areas of the container, which may increase the absorption of moisture on the surface. The deposition of moisture in this stressed region could lead to pitting and stress corrosion cracking. During FY2013, the inner container closure weld area was more closely evaluated on several archived samples from DE containers. These containers included FY09 DE2, FY12 DE4, FY12 DE6 and FY12 DE7 and the Hanford High Moisture Container. The additional examinations included visual observations with a stereomicroscope, scanning electron microscopy along with energy dispersive spectroscopy for chemical analysis, and serial metallography of the sidewall and lid that are part of the inner container closure weld region. Pitting was observed in all the samples taken from the closure weld regions of the examined inner containers. This pitting was generally less 20 μm with most less than 5m. These pits were similar in depth to those observed in the vapor exposed surfaces of teardrops in the shelf life corrosion testing. Cracking was not observed on either the vapor-exposed surfaces of the teardrop coupons or the inner container closure weld region. Further testing is necessary to determine if the conditions in the welded inner container could support SCC during the 50 year life time for the 3013 container.« less

  18. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  19. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  20. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  1. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  2. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  3. Port closure techniques.

    PubMed

    Shaher, Z

    2007-08-01

    Laparoscopic trocars do create wounds. This article aims to review and list different techniques used for closure of the fascia incision at trocar sites. A literature search was performed for articles dealing with closure techniques. The author searched this subject in English on Medline by combining the words "trocar" and "hernia," as well as "Deschamps" and "Reverdin." All articles reporting techniques with their references were reviewed. The articles described many techniques in addition to classical closure using curved needles, including Grice needle, Maciol needles, Endoclose device, Carter-Thomason device, Tahoe ligature device, Endo-Judge device, eXit puncture closure device, Lowsley retractor, spinal cord needles, dual hemostat, suture carrier, Riverdin and Deschamps needles, and Gore-Tex closure device. Three main groups of techniques were found with favor of extracorporeal manipulations under direct visualization. Old methods are sufficient and cost-effective.

  4. 49 CFR Appendix A to Part 180 - Internal Self-closing Stop Valve Emergency Closure Test for Liquefied Compressed Gases

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Part 180—Internal Self-closing Stop Valve Emergency Closure Test for Liquefied Compressed Gases 1. In performing this test, all internal self-closing stop valves must be opened. Each emergency discharge control... 49 Transportation 3 2011-10-01 2011-10-01 false Internal Self-closing Stop Valve Emergency Closure...

  5. Post-Closure Inspection Report for the Tonopah Test Range, Nevada, for Calendar Year 2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silvas, A. J.; Lantow, Tiffany A.

    This report provides the results of the annual post-closure inspections conducted at the closed Corrective Action Units (CAUs) located on the Tonopah Test Range (TTR), Nevada. This report covers calendar year 2014 and includes inspection and repair activities completed at the following CAUs; CAU 400: Bomblet Pit and Five Points Landfill (TTR); CAU 407: Roller Coaster RadSafe Area (TTR); CAU 424: Area 3 Landfill Complexes (TTR); CAU 453: Area 9 UXO Landfill (TTR); and CAU 487: Thunderwell Site (TTR) Inspections were conducted according to the post-closure plans in the approved Closure Reports and subsequent correspondence with the Nevada Division ofmore » Environmental Protection. The post-closure inspection plans and subsequent correspondence modifying the requirements for each CAU are included in Appendix B. The inspection checklists are included in Appendix C. Photographs taken during inspections are included in Appendix D. The annual post-closure inspections were conducted on May 28, 2014. Maintenance was required at CAU 407. Animal burrows were backfilled and erosion repairs were performed. Vegetation monitoring was performed at CAU 407 in June 2014. The vegetation monitoring report is included in Appendix E.« less

  6. DEVELOPMENT OF RECOMMENDATIONS AND METHODS TO SUPPORT ASSESSMENT OF SOIL VENTING PERFORMANCE AND CLOSURE: PUBLISHED REPORT

    EPA Science Inventory

    The purpose of this document is to improve the current "state of the art" and "state of the science" of soil venting application. A strategy is proposed for venting closure. A vadose zone paradigm is developed to dynamically link the performance of ground-water remediation to va...

  7. 10 CFR 63.113 - Performance objectives for the geologic repository after permanent closure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Performance objectives for the geologic repository after permanent closure. 63.113 Section 63.113 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH... and an engineered barrier system. (b) The engineered barrier system must be designed so that, working...

  8. 10 CFR 63.113 - Performance objectives for the geologic repository after permanent closure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Performance objectives for the geologic repository after permanent closure. 63.113 Section 63.113 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH... and an engineered barrier system. (b) The engineered barrier system must be designed so that, working...

  9. 10 CFR 63.113 - Performance objectives for the geologic repository after permanent closure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Performance objectives for the geologic repository after permanent closure. 63.113 Section 63.113 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH... and an engineered barrier system. (b) The engineered barrier system must be designed so that, working...

  10. 10 CFR 63.113 - Performance objectives for the geologic repository after permanent closure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Performance objectives for the geologic repository after permanent closure. 63.113 Section 63.113 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH... and an engineered barrier system. (b) The engineered barrier system must be designed so that, working...

  11. John Lumley's Contributions to Turbulence Modeling

    NASA Astrophysics Data System (ADS)

    Pope, Stephen

    2015-11-01

    We recall the contributions that John Lumley made to turbulence modeling in the 1970s and 1980s. In these early days, computer power was feeble by today's standards, and eddy-viscosity models were prevalent in CFD. Lumley recognized, however, that second-moment closures represent the simplest level at which the physics of turbulent flows can reasonably be represented. This is especially true when the velocity field is coupled to scalar fields through buoyancy, as in the atmosphere and oceans. While Lumley was not the first to propose second-moment closures, he can be credited with establishing the rational approach to constructing such closures. This includes the application of various invariance principles and tensor representation theorems, imposing the constraints imposed by realizability, and of course appealing to experimental data in simple, canonical flows. These techniques are now well-accepted and have found application far beyond second-moment closures.

  12. [Comparison of anterior chamber angle examination by UBM, SL-OCT and gonioscopy].

    PubMed

    Liu, Rui-jue; Wang, Men; Xia, Wen-tao; Yu, Xiao-ying; Chen, Jie-min; Zhou, Shu; Peng, Shu-ya; Liu, Dong-mei

    2014-08-01

    To compare the agreement of anterior chamber angle examination by ultrasound biomicroscope (UBM), slit lamp optical coherence tomography (SL-OCT), and gonioscopy in angle recession and angle closure. The anterior chamber angle was measured with UBM, SL-OCT and gonioscopy in turns for temporal, nasal, superior and inferior quadrant in the same dark room. The results were compared with the agreement of the three methods in angle recession and angle closure by χ2 test and Kappa test. There were no statistically significant differences of the three methods in testing angle closure and angle recession (P>0.05). The consistency of UBM and gonioscopy was better (Kappa value of 0.882) than that of SL-OCT and gonioscopy (Kappa value of 0.624). When testing angle recession, UBM is better than SL-OCT with gonioscopy as the standard. When testing angle closure, UBM, SL-OCT and gonioscopy have good agreement.

  13. Effect of a part-span variable inlet guide vane on the performance of a high-bypass turbofan engine

    NASA Technical Reports Server (NTRS)

    Bobula, G. A.; Soeder, R. H.; Burkardt, L. A.

    1981-01-01

    The ability of a part span variable inlet guide vane (VIGV) to modulate the thrust of a high bypass turbofan engine was evaluated at altitude/Mach number conditions of 4572 m/0.6 and 9144 m/0.93. Fan tip, gas generator and supercharger performance were also determined, both on operating lines and during fan duct throttling. The evaluation was repeated with the bypass splitter extended forward to near the fan blade trailing edge. Gross thrust attentuation of over 50 percent was achieved with 50 degree VIGV closure at 100 percent corrected fan speed. Gas generator supercharger performance fell off with VIGV closure, but this loss was reduced when a splitter extension was added. The effect of VIVG closure on gas generator performance was minimal.

  14. Greater Success of Primary Fascial Closure of the Open Abdomen: A Retrospective Study Analyzing Applied Surgical Techniques, Success of Fascial Closure, and Variables Affecting the Results.

    PubMed

    Kääriäinen, M; Kuuskeri, M; Helminen, M; Kuokkanen, H

    2017-06-01

    The open abdomen technique is a standard procedure in the treatment of intra-abdominal catastrophe. Achieving primary abdominal closure within the initial hospitalization is a main objective. This study aimed to analyze the success of closure rate and the effect of negative pressure wound therapy, mesh-mediated medial traction, and component separation on the results. We present the treatment algorithm used in our institution in open abdomen situations based on these findings. Open abdomen patients (n = 61) treated in Tampere University Hospital from May 2005 until October 2013 were included in the study. Patient characteristics, treatment prior to closure, closure technique, and results were retrospectively collected and analyzed. The first group included patients in whom direct or bridged fascial closure was achieved, and the second group included those in whom only the skin was closed or a free skin graft was used. Background variables and variables related to surgery were compared between groups. Most of the open abdomen patients (72.1%) underwent fascial defect repair during the primary hospitalization, and 70.5% of them underwent direct fascial closure. Negative pressure wound therapy was used as a temporary closure method for 86.9% of the patients. Negative pressure wound therapy combined with mesh-mediated medial traction resulted in the shortest open abdomen time (p = 0.039) and the highest fascial repair rate (p = 0.000) compared to negative pressure wound therapy only or no negative pressure wound therapy. The component separation technique was used for 11 patients; direct fascial closure was achieved in 5 and fascial repair by bridging the defect with mesh was achieved in 6. A total of 8 of 37 (21.6%) patients with mesh repair had a mesh infection. The negative pressure wound therapy combined with mesh-mediated medial traction promotes definitive fascial closure with a high closure rate and a shortened open abdomen time. The component separation technique can be used to facilitate fascial repair but it does not guarantee direct fascial closure in open abdomen patients.

  15. Seven-year follow-up of percutaneous closure of patent foramen ovale.

    PubMed

    Mirzada, Naqibullah; Ladenvall, Per; Hansson, Per-Olof; Johansson, Magnus Carl; Furenäs, Eva; Eriksson, Peter; Dellborg, Mikael

    2013-12-01

    Observational studies favor percutaneous closure of patent foramen ovale (PFO) over medical treatment to reduce recurrent stroke while randomized trials fail to demonstrate significant superiority of percutaneous PFO closure. Few long-term studies are available post PFO closure. This study reports long-term clinical outcomes after percutaneous PFO closure. Between 1997 and 2006, 86 consecutive eligible patients with cerebrovascular events, presumably related to PFO, underwent percutaneous PFO closure. All 86 patients were invited to a long-term follow-up, which was carried out during 2011 and 2012. Percutaneous PFO closure was successfully performed in 85 of 86 patients. The follow-up rate was 100%. No cardiovascular or cerebrovascular deaths occurred. Two patients (both women) died from lung cancer during follow-up. Follow-up visits were conducted for 64 patients and the remaining 20 patients were followed up by phone. The mean follow-up time was 7.3 years (5 to 12.4 years). Mean age at PFO closure was 49 years. One patient had a minor stroke one month after PFO closure and a transient ischemic attack (TIA) two years afterwards. One other patient suffered from a TIA six years after closure. No long-term device-related complications were observed. Percutaneous PFO closure was associated with very low risk of recurrent stroke and is suitable in most patients. We observed no mortality and no long-term device-related complications related to PFO closure, indicating that percutaneous PFO closure is a safe and efficient treatment even in the long term.

  16. 40 CFR 267.142 - Cost estimate for closure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... zero cost for hazardous wastes, or non-hazardous wastes that might have economic value. (b) During the... Section 267.142 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES OPERATING UNDER A STANDARDIZED...

  17. 40 CFR 267.142 - Cost estimate for closure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... zero cost for hazardous wastes, or non-hazardous wastes that might have economic value. (b) During the... Section 267.142 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES OPERATING UNDER A STANDARDIZED...

  18. 40 CFR 267.142 - Cost estimate for closure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... zero cost for hazardous wastes, or non-hazardous wastes that might have economic value. (b) During the... Section 267.142 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES OPERATING UNDER A STANDARDIZED...

  19. Vacuum-assisted wound closure and mesh-mediated fascial traction for open abdomen therapy - a systematic review.

    PubMed

    Acosta, Stefan; Björck, Martin; Petersson, Ulf

    2017-01-01

    The aim of this paper was to review the literature on vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) in open abdomen therapy. It was designed as systematic review of observational studies. A Pub Med, EMBASE and Cochrane search from 2007/01-2016/07 was performed combining the Medical Subject Headings "vacuum", "mesh-mediated fascial traction", "temporary abdominal closure", "delayed abdominal closure", "open abdomen", "abdominal compartment syndrome", "negative pressure wound therapy" or "vacuum assisted wound closure". Eleven original studies were found including patients numbering from 7 to 111. Six studies were prospective and five were retrospective. Nine studies were on mixed surgical (n = 9), vascular (n = 6) and trauma (n = 6) patients, while two were exclusively on vascular patients. The primary fascial closure rate per protocol varied from 80-100%. The time to closure of the open abdomen varied between 9-32 days. The entero-atmospheric fistula rate varied from 0-10.0%. The in-hospital survival rate varied from 57-100%. In the largest prospective study, the incisional hernia rate among survivors at 63 months of median follow-up was 54% (27/50), and 16 (33%) repairs out of 48 incisional hernias were performed throughout the study period. The study patients reported lower short form health survey (SF-36) scores than the mean reference population, mainly dependent on the prevalence of major co-morbidities. There was no difference in SF-36 scores or a modified ventral hernia pain questionnaire (VHPQ) at 5 years of follow up between those with versus those without incisional hernias. A high primary fascial closure rate can be achieved with the vacuum-assisted wound closure and meshmediated fascial traction technique in elderly, mainly non-trauma patients, in need of prolonged open abdomen therapy.

  20. Transverse closure of mesenterico-portal vein after vein resection in pancreatoduodenectomy.

    PubMed

    Chua, T C; de Reuver, P R; Staerkle, R F; Neale, M L; Arena, J; Mittal, A; Shanbhag, S T; Gill, A J; Samra, J S

    2016-02-01

    Resection of the involved mesenteric-portal vein (MPV) is increasingly performed in pancreatoduodenectomy. The primary aim of this study is to assess the rate of R0 resection in transverse closure (TC) versus segmental resection with end-to-end (EE) closure and the secondary aims are to assess the short-term morbidity and long-term survival of TC versus EE. Patients undergoing pancreatoduodenectomy with MPV resection were identified from a prospectively database. The reconstruction technique were examined and categorized. Clinical, pathological, short-term and long-term survival outcomes were compared between groups. 110 patients underwent PD with MPV resection of which reconstruction was performed with an end-to-end technique in 92 patients (84%) and transverse closure technique in 18 patients (16%). Patients undergoing transverse closure tended to have had a shorter segment of vein resected (≤2 cm) compared to the end-to-end (83% vs. 43%; P = 0.004) with no difference in R0 rate. Short-term morbidity was similar. The median and 5-year survival was 30.0 months and 18% respectively for patients undergoing transverse closure and 28.6 months and 7% respectively for patients undergoing end-to-end reconstruction (P = 0.766). Without compromising the R0 rate, transverse closure to reconstruct the mesenteric-portal vein is shown to be feasible and safe in the setting when a short segment of vein resection is required during pancreatoduodenectomy. Synopsis - We describe a vein closure technique, transverse closure, which avoids the need for a graft, or re-implantation of the splenic vein when resection of the mesenteric-portal vein confluence is required during pancreatoduodenectomy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Transcatheter Closure of Patent Foramen Ovale: A Single Center Experience.

    PubMed

    Milev, Ivan; Zafirovska, Planinka; Zimbakov, Zan; Idrizi, Shpend; Ampova-Sokolov, Vilma; Gorgieva, Emilija; Ilievska, Liljana; Tosheski, Goce; Hristov, Nikola; Georgievska-Ismail, Ljubica; Anguseva, Tanja; Mitrev, Zan

    2016-12-15

    Percutaneous transcatheter closure (PTC) of patent foramen ovale (PFO) is implicated in cryptogenic stroke, transitional ischemic attack (TIA) and treatment of a migraine. Our goal was to present our experience in the interventional treatment of PFO, as well as to evaluate the short and mid-term results in patients with closed PFO. Transcatheter closure of PFO was performed in 52 patients (67.3% women, mean age 40.7 ± 11.7 years). Patients were interviewed for subjective grading of the intensity of headaches before and after the PFO closure. During 2 years of follow-up, there was no incidence of new stroke, TIA and/or syncope. Follow-up TCD performed in 35 patients showed complete PFO closure in 20 patients (57.1%). Out of 35 patients, 22 (62.9%) reported having a migraine before the procedure with an intensity of headaches at 8.1 ± 1.9 on a scale from 1 to 10. During 2 years of follow-up, symptoms of a migraine disappeared in 4 (18.2%) and the remaining 18 patients reported the significant decrease in intensity 4.8 ± 2.04 (p = 0.0001). In addition, following PFO closure the incidence of the headaches decreased significantly (p = 0.0001). Percutaneous transcatheter closure of PFO is a safe and effective procedure showing mid-term relief of neurological symptoms in patients as well as significant reduction of migraine symptoms.

  2. School closures during the 2009 influenza pandemic: national and local experiences

    PubMed Central

    2014-01-01

    Background School closure is a non-pharmaceutical intervention that was considered in many national pandemic plans developed prior to the start of the influenza A(H1N1)pdm09 pandemic, and received considerable attention during the event. Here, we retrospectively review and compare national and local experiences with school closures in several countries during the A(H1N1)pdm09 pandemic. Our intention is not to make a systematic review of country experiences; rather, it is to present the diversity of school closure experiences and provide examples from national and local perspectives. Methods Data were gathered during and following a meeting, organized by the European Centres for Disease Control, on school closures held in October 2010 in Stockholm, Sweden. A standard data collection form was developed and sent to all participants. The twelve participating countries and administrative regions (Bulgaria, China, France, Hong Kong Special Administrative Region (SAR), Italy, Japan, New Zealand, Serbia, South Africa, Thailand, United Kingdom, and United States) provided data. Results Our review highlights the very diverse national and local experiences on school closures during the A(H1N1)pdm09 pandemic. The processes including who was in charge of making recommendations and who was in charge of making the decision to close, the school-based control strategies, the extent of school closures, the public health tradition of responses and expectations on school closure varied greatly between countries. Our review also discusses the many challenges associated with the implementation of this intervention and makes recommendations for further practical work in this area. Conclusions The single most important factor to explain differences observed between countries may have been the different public health practises and public expectations concerning school closures and influenza in the selected countries. PMID:24739814

  3. 78 FR 10163 - Notice of Availability of Draft Section 3116 Basis for Determination for Closure of H Tank Farm...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-13

    ... isolation in a deep geologic repository for spent fuel or high-level radioactive waste; (2) has had highly... in 10 CFR Part 61, Subpart C and pursuant to a State approved closure plan or State-issued permit; or... with the performance objectives of 10 CFR Part 61, Subpart C; pursuant to a State approved closure plan...

  4. Predictors of transient left ventricular dysfunction following transcatheter patent ductus arteriosus closure in pediatric age.

    PubMed

    Agha, Hala Mounir; Hamza, Hala S; Kotby, Alyaa; Ganzoury, Mona E L; Soliman, Nanies

    2017-10-01

    To evaluate the left ventricular function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure, and to identify the predictors of myocardial dysfunction post-PDA closure if present. Transcatheter PDA closure; conventional, Doppler, and tissue Doppler imaging; and speckle tracking echocardiography. To determine the feasibility and reliability of tissue Doppler and myocardial deformation imaging for evaluating myocardial function in children undergoing transcatheter PDA closure. Forty-two children diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler, and tissue Doppler imaging, and speckle-derived strain rate echocardiography were performed at preclosure and at 48 hours, 1 month, and 6 months postclosure. Tissue Doppler velocities of the lateral and septal mitral valve annuli were obtained. Global and regional longitudinal peak systolic strain values were determined using two-dimensional speckle tracking echocardiography. The median age of the patients was 2 years and body weight was 15 kg, with the mean PDA diameter of 3.11 ± 0.99 mm. M-mode measurements (left ventricular end diastolic diameter, left atrium diameter to aortic annulus ratio, ejection fraction, and shortening fraction) reduced significantly early after PDA closure ( p  < 0.001). After 1 month, left ventricular end diastolic diameter and left atrium diameter to aortic annulus ratio continued to decrease, while ejection fraction and fractional shortening improved significantly. All tissue Doppler velocities showed a significant decrease at 48 hours with significant prolongation of global myocardial function ( p  < 0.001) and then were normalized within 1 month postclosure. Similarly, global longitudinal strain significantly decreased at 48 hours postclosure ( p  < 0.001), which also recovered at 1 month follow-up. Preclosure global longitudinal strain showed a good correlation with the postclosure prolongation of the myocardial performance index. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure, which recovers completely within 1 month. Preclosure global longitudinal strain can be a predictor of postclosure myocardial dysfunction.

  5. Positive Catch & Economic Benefits of Periodic Octopus Fishery Closures: Do Effective, Narrowly Targeted Actions 'Catalyze' Broader Management?

    PubMed

    Oliver, Thomas A; Oleson, Kirsten L L; Ratsimbazafy, Hajanaina; Raberinary, Daniel; Benbow, Sophie; Harris, Alasdair

    2015-01-01

    Eight years of octopus fishery records from southwest Madagascar reveal significant positive impacts from 36 periodic closures on: (a) fishery catches and (b) village fishery income, such that (c) economic benefits from increased landings outweigh costs of foregone catch. Closures covered ~20% of a village's fished area and lasted 2-7 months. Octopus landings and catch per unit effort (CPUE) significantly increased in the 30 days following a closure's reopening, relative to the 30 days before a closure (landings: +718%, p<0.0001; CPUE: +87%, p<0.0001; n = 36). Open-access control sites showed no before/after change when they occurred independently of other management ("no ban", n = 17/36). On the other hand, open-access control sites showed modest catch increases when they extended a 6-week seasonal fishery shutdown ("ban", n = 19/36). The seasonal fishery shutdown affects the entire region, so confound all potential control sites. In villages implementing a closure, octopus fishery income doubled in the 30 days after a closure, relative to 30 days before (+132%, p<0.001, n = 28). Control villages not implementing a closure showed no increase in income after "no ban" closures and modest increases after "ban" closures. Villages did not show a significant decline in income during closure events. Landings in closure sites generated more revenue than simulated landings assuming continued open-access fishing at that site (27/36 show positive net earnings; mean +$305/closure; mean +57.7% monthly). Benefits accrued faster than local fishers' time preferences during 17-27 of the 36 closures. High reported rates of illegal fishing during closures correlated with poor economic performance. We discuss the implications of our findings for broader co-management arrangements, particularly for catalyzing more comprehensive management.

  6. A review of near-wall Reynolds-stress

    NASA Technical Reports Server (NTRS)

    So, R. M. C.; Lai, Y. G.; Zhang, H. S.; Hwang, B. C.

    1991-01-01

    The advances made in second-order near-wall turbulence closures are summarized. All closures examined are based on some form of high Reynolds number models for the Reynolds stress and the turbulent kinetic energy dissipation rate equations. Consequently, most near-wall closures proposed to data attempt to modify the high Reynolds number models for the dissipation rate equation so that the resultant models are applicable all the way to the wall. The near-wall closures are examined for their asymptotic behavior so that they can be compared with the proper near-wall behavior of the exact equations. A comparison of the closure's performance in the calculation of a low Reynolds number plane channel flow is carried out. In addition, the closures are evaluated for their ability to predict the turbulence statistics and the limiting behavior of the structure parameters compared to direct simulation data.

  7. Stretched size of atrial septal defect predicted by intracardiac echocardiography.

    PubMed

    Lin, Ming-Chih; Fu, Yun-Ching; Jan, Sheng-Ling; Ho, Chi-Lin; Hwang, Betau

    2010-01-01

    The stretched size of an atrial septal defect (ASD) is important for device selection during transcatheter closure. However, balloon sizing carries potential risks such as hypotension, bradycardia, or laceration of the atrial septum. The aim of the present study was to investigate the accuracy of the predicted stretched size of ASD by intracardiac echocardiography (ICE). From December 2004 to November 2007, 136 consecutive patients with single secundum type ASD undergoing transcatheter closure of their defect using the Amplatzer septal occluder under ICE guidance were enrolled for analysis. There were 43 males and 93 females. The age ranged from 2.2 to 79.1 years with a median age of 13.4 years. The body weight ranged from 12.1 to 93.2 kg with a median body weight of 45.8 kg. The stretched size of ASD measured by a sizing plate was considered as the standard. ASD sizes measured by ICE in bicaval and short-axis views predicted the stretched size by formulae derived from linear regressions. The predicted stretched sizes obtained using 2 formulae, 1.34 x radicalbicaval xshort axis (formula 1) and 1.22 x larger diameter (formula 2), exhibited good agreement with the standard stretched size with Kappa values of 0.91 and 0.90, respectively. The accuracy rate of predicted stretched sizes within 2 mm, 3 mm, and 4 mm range of the standard size were 32.8%, 45.4%, and 57.7% (formula 1) and 33.1%, 50%, and 63.2% (formula 2). The stretched size of ASD predicted by ICE exhibited good agreement with the standard stretched size. This prediction provides helpful information, especially if balloon sizing cannot be adequately performed.

  8. Resident-performed laser peripheral iridotomy in primary angle closure, primary angle closure suspects, and primary angle closure glaucoma.

    PubMed

    Kam, Jason P; Zepeda, Emily M; Ding, Leona; Wen, Joanne C

    2017-01-01

    To investigate the power use and complication frequency of resident-performed laser peripheral iridotomy (LPI). A retrospective analysis of 196 eyes from 103 patients who underwent neodymium: yttrium-aluminum-garnet laser iridotomy performed by resident physicians from January 1, 2010 through April 30, 2015 at a university-based county hospital was done. All patients were treated for primary angle closure, primary angle closure suspects, and primary angle closure glaucoma. Data were collected on pre- and post-laser intraocular pressure (IOP), ethnicity, laser parameters and complications. Mean power use and frequency of complications were evaluated. Complications included elevated post-laser IOP at 30-45 minutes (≥8 mmHg), hyphema, aborted procedures, and lasering non-iris structures. The number of repeated LPI procedures, was also recorded. Mean total power used for all residents was 78.2±68.7 mJ per eye. Power use by first-year trainees was significantly higher than second- and third-year trainees (103.5±75.5 mJ versus 73.7±73.8 mJ and 67.2±56.4 mJ, respectively, p =0.011). Complications included hyphema or microhyphema in 17.9% (35/196), IOP spikes in 5.1% (10/196), aborted procedures in 1.1% (3/196) and lasering non-iris structures in 0.5% (1/196). LPI was repeated in 22.4% of cases (44/196) with higher incidence of repeat LPI among non-Caucasian compared to the Caucasian subjects ( p =0.02). Complication rates did not differ with increased training ( p =0.16). Total power used for LPI decreased with increased resident training, while the complication rate did not differ significantly among resident classes. Complication rates were comparable to rates reported in the literature for attending-performed LPIs.

  9. Closure Report for Corrective Action Unit 408: Bomblet Target Area Tonopah Test Range (TTR), Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mark Krauss

    2010-09-01

    This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 408: Bomblet Target Area (TTR), Tonopah Test Range, Nevada. This CR complies with the requirements of the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. Corrective Action Unit 408 is located at the Tonopah Test Range, Nevada, and consists of Corrective Action Site (CAS) TA-55-002-TAB2, Bomblet Target Areas. This CAS includes the following seven target areas: • Mid Target • Flightline Bomblet Location •more » Strategic Air Command (SAC) Target Location 1 • SAC Target Location 2 • South Antelope Lake • Tomahawk Location 1 • Tomahawk Location 2 The purpose of this CR is to provide documentation supporting the completed corrective actions and data confirming that the closure objectives for the CAS within CAU 408 were met. To achieve this, the following actions were performed: • Review the current site conditions, including the concentration and extent of contamination. • Implement any corrective actions necessary to protect human health and the environment. • Properly dispose of corrective action and investigation wastes. • Document Notice of Completion and closure of CAU 408 issued by the Nevada Division of Environmental Protection. From July 2009 through August 2010, closure activities were performed as set forth in the Streamlined Approach for Environmental Restoration Plan for CAU 408: Bomblet Target Area, Tonopah Test Range (TTR), Nevada. The purposes of the activities as defined during the data quality objectives process were as follows: • Identify and remove munitions of explosive concern (MEC) associated with DOE activities. • Investigate potential disposal pit locations. • Remove depleted uranium-contaminated fragments and soil. • Determine whether contaminants of concern (COCs) are present. • If COCs are present, determine their nature and extent, implement appropriate corrective actions, and properly dispose of wastes. Analytes detected during the closure activities were evaluated against final action levels to determine COCs for CAU 408. Assessment of the data indicated COCs are not present at CAS TA-55-002-TAB2; therefore, no corrective action is necessary. No use restrictions are required to be placed on this CAU because the investigation showed no evidence of remaining soil contamination or remaining debris/waste upon completion of all investigation activities. The MEC was successfully removed and dispositioned as planned using current best available technologies. As MEC guidance and general MEC standards acknowledge that MEC response actions cannot determine with 100 percent certainty that all MEC and unexploded ordnance (UXO) are removed, the clean closure of CAU 408 will implement a best management practice of posting UXO hazard warning signs near the seven target areas. The signs will warn future land users of the potential for encountering residual UXO hazards. The DOE, National Nuclear Security Administration Nevada Site Office, provides the following recommendations: • A Notice of Completion to the DOE, National Nuclear Security Administration Nevada Site Office, is requested from the Nevada Division of Environmental Protection for closure of CAU 408. • Corrective Action Unit 408 should be moved from Appendix III to Appendix IV of the Federal Facility Agreement and Consent Order.« less

  10. Prognostic significance of pleural lavage cytology after thoracotomy and before closure of the chest in lung cancer.

    PubMed

    Taniguchi, Yuji; Nakamura, Hiroshige; Miwa, Ken; Adachi, Yoshin; Fujioka, Shinji; Haruki, Tomohiro; Horie, Yasushi

    2009-07-01

    Some reports have described pleural lavage cytology (PLC) to be a prognostic factor for non-small cell lung cancer (NSCLC) patients. However, there have only been a few reports describing the findings both immediately after thoracotomy (PLC after thoracotomy) and before the closure of the chest (PLC before closure). From April 2002 to April 2008, both PLC after thoracotomy and PLC before closure were performed in 296 consecutive patients who underwent resections for NSCLC. PLC after thoracotomy was positive in 14 patients. The survival rate in the PLC after thoracotomy positive cases was significantly poorer than in PLC after thoracotomy negative cases (P=0.047). In contrast, there were 26 PLC before closure positive cases. The survival rate in the PLC before closure positive cases was significantly poorer than in the PLC before closure negative cases (P<0.0001). Multivariate analyses revealed that PLC after thoracotomy is not an independent prognostic factor in our study. However, PLC before closure was an independent prognostic factor based on multivariate analyses. We conclude that PLC before closure was found to be a better prognostic factor than PLC after thoracotomy for NSCLC patients.

  11. Eradication of Helicobacter pylori for prevention of ulcer recurrence after simple closure of perforated peptic ulcer: a meta-analysis of randomized controlled trials.

    PubMed

    Wong, Chung-Shun; Chia, Chee-Fah; Lee, Hung-Chia; Wei, Po-Li; Ma, Hon-Ping; Tsai, Shin-Han; Wu, Chih-Hsiung; Tam, Ka-Wai

    2013-06-15

    Eradication of Helicobacter pylori has become part of the standard therapy for peptic ulcer. However, the role of H pylori eradication in perforation of peptic ulcers remains controversial. It is unclear whether eradication of the bacterium confers prolonged ulcer remission after simple repair of perforated peptic ulcer. A systematic review and meta-analysis of randomized controlled trials was performed to evaluate the effects of H pylori eradication on prevention of ulcer recurrence after simple closure of perforated peptic ulcers. The primary outcome to evaluate these effects was the incidence of postoperative ulcers; the secondary outcome was the rate of H pylori elimination. The meta-analysis included five randomized controlled trials and 401 patients. A high prevalence of H pylori infection occurred in patients with perforated peptic ulcers. Eradication of H pylori significantly reduced the incidence of ulcer recurrence at 8 wk (risk ratio 2.97; 95% confidence interval: 1.06-8.29) and 1 y (risk ratio 1.49; 95% confidence interval: 1.10-2.03) postoperation. The rate of H pylori eradication was significantly higher in the treatment group than in the nontreatment group. Eradication therapy should be provided to patients with H pylori infection after simple closure of perforated gastroduodenal ulcers. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Assessment of a simple, novel endoluminal method for gastrotomy closure in NOTES.

    PubMed

    Lee, Sang Soo; Oelschlager, Brant K; Wright, Andrew S; Soares, Renato V; Sinan, Huseyin; Montenovo, Martin I; Hwang, Joo Ha

    2011-10-01

    A reliable method for gastrotomy closure in NOTES will be essential for NOTES to become viable clinically. However, methods using existing and widely available endoscopic accessories have been ineffective. The objective of this study was to evaluate the feasibility and safety of a new simple method for gastric closure (retracted clip-assisted loop closure) that uses existing endoscopic accessories with minor modifications. The retracted clip-assisted loop closure technique involves deploying 3-4 Resolution(®) clips (modified by attaching a 90-cm length of suture to the end of each clip) along the margin of the gastrotomy with one jaw on the serosal surface and the other jaw on the mucosal surface. The suture strings are threaded through an endoloop. Traction is then applied to the strings causing the gastric wall to tent. The endoloop is secured below the tip of the clips, completing a full-thickness gastrotomy closure. The main outcome measures were feasibility, efficacy, and safety of the new retracted clip-assisted loop closure technique for NOTES gastrotomy closure. An air-tight seal was achieved in 100% (n = 9) of stomachs. The mean leak pressure was 116.3 (±19.4) mmHg. The retracted clip-assisted loop closure technique can be used to perform NOTES gastrotomy closure by using existing endoscopic accessories with minor modifications.

  13. Long-Term Follow-Up Study of Young Adults Treated for Unilateral Complete Cleft Lip, Alveolus, and Palate by a Treatment Protocol Including Two-Stage Palatoplasty: Speech Outcomes

    PubMed Central

    Bittermann, Dirk; Janssen, Laura; Bittermann, Gerhard Koendert Pieter; Boonacker, Chantal; Haverkamp, Sarah; de Wilde, Hester; Van Der Heul, Marise; Specken, Tom FJMC; Koole, Ron; Kon, Moshe; Breugem, Corstiaan Cornelis; Mink van der Molen, Aebele Barber

    2017-01-01

    Background No consensus exists on the optimal treatment protocol for orofacial clefts or the optimal timing of cleft palate closure. This study investigated factors influencing speech outcomes after two-stage palate repair in adults with a non-syndromal complete unilateral cleft lip and palate (UCLP). Methods This was a retrospective analysis of adult patients with a UCLP who underwent two-stage palate closure and were treated at our tertiary cleft centre. Patients ≥17 years of age were invited for a final speech assessment. Their medical history was obtained from their medical files, and speech outcomes were assessed by a speech pathologist during the follow-up consultation. Results Forty-eight patients were included in the analysis, with a mean age of 21 years (standard deviation, 3.4 years). Their mean age at the time of hard and soft palate closure was 3 years and 8.0 months, respectively. In 40% of the patients, a pharyngoplasty was performed. On a 5-point intelligibility scale, 84.4% received a score of 1 or 2; meaning that their speech was intelligible. We observed a significant correlation between intelligibility scores and the incidence of articulation errors (P<0.001). In total, 36% showed mild to moderate hypernasality during the speech assessment, and 11%–17% of the patients exhibited increased nasalance scores, assessed through nasometry. Conclusions The present study describes long-term speech outcomes after two-stage palatoplasty with hard palate closure at a mean age of 3 years old. We observed moderate long-term intelligibility scores, a relatively high incidence of persistent hypernasality, and a high pharyngoplasty incidence. PMID:28573094

  14. Comparison of two neonatal indomethacin protocols: efficacy and outcome for patent ductus arteriosus closure.

    PubMed

    Rosito, G; Sum, K; Chorne, N

    2010-10-01

    Indomethacin, a non-selective inhibitor of prostaglandin synthesis, is the gold standard treatment for patent ductus arteriosus (PDA). Indomethacin has been shown to permanently close the ductus and when given prophylactically, it reduces the incidence of PDA (1, 2). This study compares PDA closure and surgical ligation rates between patients using two different indomethacin administration protocols. This is a retrospective comparison analysis of 72 neonates, who received one of two indomethacin administration protocols. Our previous protocol suggested an initial dose of 0·2 mg/kg followed by two 0·1 mg/kg, with doses infused over 4 h and a 24-h dosing interval. A new potentially more useful protocol using the same mg/kg dose regimen but with doses infused over 30 min and a 12-h dosing interval, was evaluated. Each neonate was allowed three courses of treatment before surgical ligation was performed for persistent PDA. There were no statistically significant differences between the two protocol groups when comparing percentages of neonates with gestational age≤28 weeks, birth weight≤1000 g, male gender or receiving indomethacin for the indication of PDA prophylaxis vs. treatment. There was a trend towards a higher PDA closure rate and subsequently a lower PDA ligation rate in the new protocol when compared with the previous protocol. In this small population of premature neonates, there was a trend, but no significant difference, towards increasing PDA closure and lower surgical ligation rates in neonates given indomethacin with more frequent dosing and shorter infusion time. A well-powered randomized controlled trial is now needed. Copyright © 2010 The Authors. JCPT © 2010 Blackwell Publishing Ltd.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eric Larsen; Art Watkins; Timothy R. McJunkin

    The U.S. Department of Energy (DOE) created the National Spent Nuclear Fuel Program (NSNFP) to manage DOE’s spent nuclear fuel (SNF). One of the NSNFP’s tasks is to prepare spent nuclear fuel for storage, transportation, and disposal at the national repository. As part of this effort, the NSNFP developed a standardized canister for interim storage and transportation of SNF. These canisters will be built and sealed to American Society of Mechanical Engineers (ASME) Section III, Division 3 requirements. Packaging SNF usually is a three-step process: canister loading, closure welding, and closure weld verification. After loading SNF into the canisters, themore » canisters must be seal welded and the welds verified using a combination of visual, surface eddy current, and ultrasonic inspection or examination techniques. If unacceptable defects in the weld are detected, the defective sections of weld must be removed, re-welded, and re-inspected. Due to the high contamination and/or radiation fields involved with this process, all of these functions must be performed remotely in a hot cell. The prototype apparatus to perform these functions is a floor-mounted carousel that encircles the loaded canister; three stations perform the functions of welding, inspecting, and repairing the seal welds. A welding operator monitors and controls these functions remotely via a workstation located outside the hot cell. The discussion describes the hardware and software that have been developed and the results of testing that has been done to date.« less

  16. Radiation-induced impairment of osseous healing: Quantitative studies usine a standard drilling defect in rat femur

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, M.; Kummermehr, J.; Trott, K.R.

    1995-07-01

    The femora of adult Wistar rats were locally irradiated with single doses of X rays and 1 day later were wounded by a standardized drilling defect that extended through the diaphyseal cortex into the marrow cavity. Healing of the lesion was followed over 30 weeks to assess the time course of osseous closure. In unirradiated bones healing was complete by week 7. Irradiation with doses up to 15 Gy imparted a dose-dependent delay in the formation of primary callus and its subsequent replacement by more mature bone, while after higher doses healing doses healing remained permanently comprised or even suppressed.more » Using histomorphometry, osseous closure was also measured quantitatively for healing periods of 7, 10, 16 and 30 weeks and the data were expressed as the percentage of responders with {ge}40% fractional closure. the resulting dose-response curves were steep, displaying a large threshold dose and ED{sub 50} values between 16.8 to 17.5 Gy (7 to 16 weeks) and 19.4 Gy (30 weeks), respectively. 35 refs., 4 figs., 2 tabs.« less

  17. On the modelling of non-reactive and reactive turbulent combustor flows

    NASA Technical Reports Server (NTRS)

    Nikjooy, Mohammad; So, Ronald M. C.

    1987-01-01

    A study of non-reactive and reactive axisymmetric combustor flows with and without swirl is presented. Closure of the Reynolds equations is achieved by three models: kappa-epsilon, algebraic stress and Reynolds stress closure. Performance of two locally nonequilibrium and one equilibrium algebraic stress models is analyzed assuming four pressure strain models. A comparison is also made of the performance of a high and a low Reynolds number model for combustor flow calculations using Reynolds stress closures. Effects of diffusion and pressure-strain models on these closures are also investigated. Two models for the scalar transport are presented. One employs the second-moment closure which solves the transport equations for the scalar fluxes, while the other solves the algebraic equations for the scalar fluxes. In addition, two cases of non-premixed and one case of premixed combustion are considered. Fast- and finite-rate chemistry models are applied to non-premixed combustion. Both show promise for application in gas turbine combustors. However, finite rate chemistry models need to be examined to establish a suitable coupling of the heat release effects on turbulence field and rate constants.

  18. Patent foramen ovale closure and medical treatments for secondary stroke prevention: a systematic review of observational and randomized evidence.

    PubMed

    Kitsios, Georgios D; Dahabreh, Issa J; Abu Dabrh, Abd Moain; Thaler, David E; Kent, David M

    2012-02-01

    Patients discovered to have a patent foramen ovale in the setting of a cryptogenic stroke may be treated with percutaneous closure, antiplatelet therapy, or anticoagulants. A recent randomized trial (CLOSURE I) did not detect any benefit of closure over medical treatment alone; the optimal medical therapy is also unknown. We synthesized the available evidence on secondary stroke prevention in patients with patent foramen ovale and cryptogenic stroke. A MEDLINE search was performed for finding longitudinal studies investigating medical treatment or closure, meta-analysis of incidence rates (IR), and IR ratios of recurrent cerebrovascular events. Fifty-two single-arm studies and 7 comparative nonrandomized studies and the CLOSURE I trial were reviewed. The summary IR of recurrent stroke was 0.36 events (95% confidence interval [CI], 0.24-0.56) per 100 person-years with closure versus 2.53 events (95% CI, 1.91-3.35) per 100 person-years with medical therapy. In comparative observational studies, closure was superior to medical therapy (IR ratio=0.19; 95% CI, 0.07-0.54). The IR for the closure arm of the CLOSURE I trial was higher than the summary estimate from observational studies; there was no significant benefit of closure over medical treatment (P=0.002 comparing efficacy estimates between observational studies and the trial). Observational and randomized data (9 studies) comparing medical therapies were consistent and suggested that anticoagulants are superior to antiplatelets for preventing stroke recurrence (IR ratio=0.42; 95% CI, 0.18-0.98). Although further randomized trial data are needed to precisely determine the effects of closure on stroke recurrence, the results of CLOSURE I challenge the credibility of a substantial body of observational evidence strongly favoring mechanical closure over medical therapy.

  19. Use of cartilage grafts for closure of cleft palate fistulae.

    PubMed

    Jeffery, S L; Boorman, J G; Dive, D C

    2000-10-01

    We describe the results of using a free cartilage graft in the closure of cleft palate fistulae in 14 patients with a mean follow-up of 8.6 months. Complete closure of the fistula was achieved in 11 patients (79%), with partial closure in the remaining three patients. This technique is simple, causes relatively little discomfort, involves little tissue dissection and can be performed as a day-case procedure. The success rate is comparable with or better than other methods, and we consider it the treatment of choice for small cleft palate fistulae. Copyright 2000 The British Association of Plastic Surgeons.

  20. Fluid simulation of tokamak ion temperature gradient turbulence with zonal flow closure model

    NASA Astrophysics Data System (ADS)

    Yamagishi, Osamu; Sugama, Hideo

    2016-03-01

    Nonlinear fluid simulation of turbulence driven by ion temperature gradient modes in the tokamak fluxtube configuration is performed by combining two different closure models. One model is a gyrofluid model by Beer and Hammett [Phys. Plasmas 3, 4046 (1996)], and the other is a closure model to reproduce the kinetic zonal flow response [Sugama et al., Phys. Plasmas 14, 022502 (2007)]. By including the zonal flow closure, generation of zonal flows, significant reduction in energy transport, reproduction of the gyrokinetic transport level, and nonlinear upshift on the critical value of gradient scale length are observed.

  1. Fluid simulation of tokamak ion temperature gradient turbulence with zonal flow closure model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamagishi, Osamu, E-mail: yamagisi@nifs.ac.jp; Sugama, Hideo

    Nonlinear fluid simulation of turbulence driven by ion temperature gradient modes in the tokamak fluxtube configuration is performed by combining two different closure models. One model is a gyrofluid model by Beer and Hammett [Phys. Plasmas 3, 4046 (1996)], and the other is a closure model to reproduce the kinetic zonal flow response [Sugama et al., Phys. Plasmas 14, 022502 (2007)]. By including the zonal flow closure, generation of zonal flows, significant reduction in energy transport, reproduction of the gyrokinetic transport level, and nonlinear upshift on the critical value of gradient scale length are observed.

  2. Closedure - Mine Closure Technologies Resource

    NASA Astrophysics Data System (ADS)

    Kauppila, Päivi; Kauppila, Tommi; Pasanen, Antti; Backnäs, Soile; Liisa Räisänen, Marja; Turunen, Kaisa; Karlsson, Teemu; Solismaa, Lauri; Hentinen, Kimmo

    2015-04-01

    Closure of mining operations is an essential part of the development of eco-efficient mining and the Green Mining concept in Finland to reduce the environmental footprint of mining. Closedure is a 2-year joint research project between Geological Survey of Finland and Technical Research Centre of Finland that aims at developing accessible tools and resources for planning, executing and monitoring mine closure. The main outcome of the Closedure project is an updatable wiki technology-based internet platform (http://mineclosure.gtk.fi) in which comprehensive guidance on the mine closure is provided and main methods and technologies related to mine closure are evaluated. Closedure also provides new data on the key issues of mine closure, such as performance of passive water treatment in Finland, applicability of test methods for evaluating cover structures for mining wastes, prediction of water effluents from mine wastes, and isotopic and geophysical methods to recognize contaminant transport paths in crystalline bedrock.

  3. Transcatheter Closure of Patent Foramen Ovale: A Single Center Experience

    PubMed Central

    Milev, Ivan; Zafirovska, Planinka; Zimbakov, Zan; Idrizi, Shpend; Ampova-Sokolov, Vilma; Gorgieva, Emilija; Ilievska, Liljana; Tosheski, Goce; Hristov, Nikola; Georgievska-Ismail, Ljubica; Anguseva, Tanja; Mitrev, Zan

    2016-01-01

    BACKGROUND: Percutaneous transcatheter closure (PTC) of patent foramen ovale (PFO) is implicated in cryptogenic stroke, transitional ischemic attack (TIA) and treatment of a migraine. AIM: Our goal was to present our experience in the interventional treatment of PFO, as well as to evaluate the short and mid-term results in patients with closed PFO. MATERIAL AND METHODS: Transcatheter closure of PFO was performed in 52 patients (67.3% women, mean age 40.7 ± 11.7 years). Patients were interviewed for subjective grading of the intensity of headaches before and after the PFO closure. RESULTS: During 2 years of follow-up, there was no incidence of new stroke, TIA and/or syncope. Follow-up TCD performed in 35 patients showed complete PFO closure in 20 patients (57.1%). Out of 35 patients, 22 (62.9%) reported having a migraine before the procedure with an intensity of headaches at 8.1 ± 1.9 on a scale from 1 to 10. During 2 years of follow-up, symptoms of a migraine disappeared in 4 (18.2%) and the remaining 18 patients reported the significant decrease in intensity 4.8 ± 2.04 (p = 0.0001). In addition, following PFO closure the incidence of the headaches decreased significantly (p = 0.0001). CONCLUSIONS: Percutaneous transcatheter closure of PFO is a safe and effective procedure showing mid-term relief of neurological symptoms in patients as well as significant reduction of migraine symptoms. PMID:28028400

  4. Hemodynamic features of congenital aortic valve stenosis with patent ductus arteriosus in children.

    PubMed

    Xie, Chunhong; Xia, Chengsen; Zhao, Zhengyan; Zhou, Yinbao

    2007-12-01

    The aim of the present paper was to investigate the hemodynamic features of congenital aortic valvar stenosis (AS) associated with patent ductus arteriosus (PDA), and to develop information to guide management of AS with coexistent PDA. Hemodynamic measurements were performed in eight of 11 patients with AS before and following transcatheter closure of a PDA. Doppler cardiac ultrasound and chest X-rays were performed during follow up. In each of the 11 patients, aortic valve gradient was markedly reduced following transcatheter ductal closure. In only one of them was balloon aortic valvuloplasty necessary. Aortic valve gradient was markedly overestimated before closure of PDA. The significance of this finding has focused on selecting appropriate management so that a PDA is not overlooked when intervention for AS is performed.

  5. Comparison of cost-effectiveness and postoperative outcome of device closure and open surgery closure techniques for treatment of patent ductus arteriosus.

    PubMed

    Ahmadi, Alireza; Sabri, Mohammadreza; Bigdelian, Hamid; Dehghan, Bahar; Gharipour, Mojgan

    2014-01-01

    Various devices have been recently employed for percutaneous closure of the patent ductus arteriosus (PDA). Although the high effectiveness of device closure techniques has been clearly determined, a few studies have focused on the cost-effectiveness and also postoperative complications of these procedures in comparison with open surgery. The present study aimed to evaluate the clinical outcome and cost-effectiveness of PDA occlusion by Amplatzer and coil device in comparisong with open surgery. In this cross-sectional study, a randomized sample of 201 patients aged 1 month to 16 years (105 patients with device closure and 96 patients with surgical closure) was selected. The ratio of total pulmonary blood flow to total systemic blood flow, the Qp/Qs ratio, was measured using a pulmonary artery catheter. The cost analysis included direct medical care costs associated with device implantation and open surgery, as well as professional fees. All costs were calculated in Iranian Rials and then converted to US dollars. There was no statistical difference in mean Qp/Qs ratio before the procedure between the device closure group and the open surgery group (2.1 ± 0.7 versus 1.7 ± 0.6, P = 0.090). The mean measured costs were overall higher in the device closure group than in open closure group (948.87 ± 548.76 US$ versus 743.70 ± 696.91 US$, P < 0.001). This difference remained significant after adjustment for age and gender (Standardized Beta = 0.160, P = 0.031). PDA closure with the Amplatzer ductal occluder (1053.05 ± 525.73 US$) or with Nit-Occlud coils (PFM) (912.73 ± 565.94 US$, P < 0.001) was more expensive than that via open surgery. However, the Cook detachable spring coils device closure (605.65 ± 194.62 US$, P = 0.650) had a non-significant cost difference with open surgery. No event was observed in the device closure group regarding in-hospital mortality or morbidity; however, in another group, 2 in-hospital deaths occurred, two patients experienced pneumonia and seizure, and one suffered electrolyte abnormalities including hyponatremia and hypocalcemia. Although open surgery seems to be less expensive than device closure technique, because of lower mortality and morbidity, the latter group is more preferable.

  6. Performance assessment for low-level waste disposal in the UK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashworth, A.B.

    1995-12-31

    British Nuclear Fuels plc (BNFL) operate a site for the disposal of Low Level Radioactive Waste at Drigg in West Cumbria, in North-West England. HMIP are responsible for the regulation of the site with regard to environmental discharges of radioactive materials, both operational and post-closure. This paper is concerned with post-closure matters only. Two post-closure performance assessments have been carried out for this site: one by the National Radiological Protection Board (NRPB) in 1987; and a subsequent one carried out on behalf of HMIP, completed in 1991. Currently, BNFL are preparing a Safety Case for continued operation of the Driggmore » site, and it expected that the core of this Case will comprise BNFL`s own analysis of post-closure performance. HMIP has developed procedures for the assessment of this Case, based upon experience of the previous Drigg assessments, and also upon the experience of similar work carried out in the assessment of Intermediate Level Waste (ILW) disposal at both deep and shallow potential sites. This paper describes the more important features of these procedures.« less

  7. Laparoscopic common bile duct exploration. Lessons learned after 200 cases.

    PubMed

    Abellán Morcillo, Israel; Qurashi, Kamran; Abrisqueta Carrión, Jesús; Martinez Isla, Alberto

    2014-05-01

    Laparoscopic common bile duct exploration (LCBDE) is a reliable, reproducible and cost-effective treatment for common bile duct stones. Several techniques have been described for choledochotomy closure. To present our experience and the lessons learned in more than 200 cases of LCBDE. Between January 1999 and July 2012, 206 patients with common bile duct stones underwent LCBDE. At the beginning of the series, we performed the closure of the CBD over a T-tube (36 patients), subsequently we favoured closure over an antegrade stent (133 patients) but due to a high incidence of acute pancreatitis in the last 16 patients we have performed primary closure. The 3 closure groups were matched for age and sex. Jaundice was the most frequent presentation. A total of 185 (88,5%) patients underwent choledochotomy whereas in 17 (8,7%) patients the transcystic route was used. The group that underwent choledochotomy had a larger size of stones compared to the transcystic group (9,7 vs 7,6mm). In the stented group we found an 11,6% incidence of pancreatitis and 26,1% of hyperamylasemia. In the primary closure group we found a clear improvement of complications and hospital stay. The increased experience of the surgeon and age (younger than 75) had a positive impact on mortality and morbidity. Primary closure of the common bile duct after LCBDE seems to be superior to closure over a T tube and stents. The learning curve seems to have a positive impact on the outcomes making it a safe and reproducible technique especially for patients aged under 75. Copyright © 2013 AEC. Published by Elsevier Espana. All rights reserved.

  8. 40 CFR 267.111 - What general standards must I meet when I stop operating the unit?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to protect human health and the environment, post-closure escape of hazardous waste, hazardous constituents, leachate, contaminated run-off, or hazardous waste decomposition products to the ground or... PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE...

  9. 40 CFR 267.111 - What general standards must I meet when I stop operating the unit?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to protect human health and the environment, post-closure escape of hazardous waste, hazardous constituents, leachate, contaminated run-off, or hazardous waste decomposition products to the ground or... PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE...

  10. Model-Based Comprehensive Analysis of School Closure Policies for Mitigating Influenza Epidemics and Pandemics

    PubMed Central

    Fumanelli, Laura; Ajelli, Marco; Merler, Stefano; Ferguson, Neil M.; Cauchemez, Simon

    2016-01-01

    School closure policies are among the non-pharmaceutical measures taken into consideration to mitigate influenza epidemics and pandemics spread. However, a systematic review of the effectiveness of alternative closure policies has yet to emerge. Here we perform a model-based analysis of four types of school closure, ranging from the nationwide closure of all schools at the same time to reactive gradual closure, starting from class-by-class, then grades and finally the whole school. We consider policies based on triggers that are feasible to monitor, such as school absenteeism and national ILI surveillance system. We found that, under specific constraints on the average number of weeks lost per student, reactive school-by-school, gradual, and county-wide closure give comparable outcomes in terms of optimal infection attack rate reduction, peak incidence reduction or peak delay. Optimal implementations generally require short closures of one week each; this duration is long enough to break the transmission chain without leading to unnecessarily long periods of class interruption. Moreover, we found that gradual and county closures may be slightly more easily applicable in practice as they are less sensitive to the value of the excess absenteeism threshold triggering the start of the intervention. These findings suggest that policy makers could consider school closure policies more diffusely as response strategy to influenza epidemics and pandemics, and the fact that some countries already have some experience of gradual or regional closures for seasonal influenza outbreaks demonstrates that logistic and feasibility challenges of school closure strategies can be to some extent overcome. PMID:26796333

  11. Model-Based Comprehensive Analysis of School Closure Policies for Mitigating Influenza Epidemics and Pandemics.

    PubMed

    Fumanelli, Laura; Ajelli, Marco; Merler, Stefano; Ferguson, Neil M; Cauchemez, Simon

    2016-01-01

    School closure policies are among the non-pharmaceutical measures taken into consideration to mitigate influenza epidemics and pandemics spread. However, a systematic review of the effectiveness of alternative closure policies has yet to emerge. Here we perform a model-based analysis of four types of school closure, ranging from the nationwide closure of all schools at the same time to reactive gradual closure, starting from class-by-class, then grades and finally the whole school. We consider policies based on triggers that are feasible to monitor, such as school absenteeism and national ILI surveillance system. We found that, under specific constraints on the average number of weeks lost per student, reactive school-by-school, gradual, and county-wide closure give comparable outcomes in terms of optimal infection attack rate reduction, peak incidence reduction or peak delay. Optimal implementations generally require short closures of one week each; this duration is long enough to break the transmission chain without leading to unnecessarily long periods of class interruption. Moreover, we found that gradual and county closures may be slightly more easily applicable in practice as they are less sensitive to the value of the excess absenteeism threshold triggering the start of the intervention. These findings suggest that policy makers could consider school closure policies more diffusely as response strategy to influenza epidemics and pandemics, and the fact that some countries already have some experience of gradual or regional closures for seasonal influenza outbreaks demonstrates that logistic and feasibility challenges of school closure strategies can be to some extent overcome.

  12. Corrective Action Decision Document/Closure Report for Corrective Action Unit 105: Area 2 Yucca Flat Atmospheric Test Sites, Nevada National Security Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, Patrick

    2013-09-01

    This Corrective Action Decision Document/Closure Report presents information supporting the closure of Corrective Action Unit (CAU) 105: Area 2 Yucca Flat Atmospheric Test Sites, Nevada National Security Site, Nevada. CAU 105 comprises the following five corrective action sites (CASs): -02-23-04 Atmospheric Test Site - Whitney Closure In Place -02-23-05 Atmospheric Test Site T-2A Closure In Place -02-23-06 Atmospheric Test Site T-2B Clean Closure -02-23-08 Atmospheric Test Site T-2 Closure In Place -02-23-09 Atmospheric Test Site - Turk Closure In Place The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation that nomore » further corrective action is needed for CAU 105 based on the implementation of the corrective actions. Corrective action investigation (CAI) activities were performed from October 22, 2012, through May 23, 2013, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 105: Area 2 Yucca Flat Atmospheric Test Sites; and in accordance with the Soils Activity Quality Assurance Plan, which establishes requirements, technical planning, and general quality practices.« less

  13. Safety of Performing a Delayed Anastomosis During Damage Control Laparotomy in Patients with Destructive Colon Injuries

    PubMed Central

    Ordoñez, Carlos A; Pino, Luis F; Badiel, Marisol; Sánchez, Alvaro I; Loaiza, Jhon; Ballestas, Leonardo; Puyana, Juan Carlos

    2011-01-01

    Background Recent studies report the safety and feasibility of performing delayed anastomosis (DA) in patients undergoing damage control laparotomy (DCL) for destructive colon injuries (DCI). Despite accumulating experience in both civilian and military trauma, questions regarding how to best identify high risk patients and minimize the number of anastomosis-associated complications remain. Our current practice is to perform a definitive closure of the colon during DCL, unless there is persistent acidosis, bowel wall edema, or evidence of intra-abdominal abscess. In this study, we evaluated the safety of this approach by comparing outcomes of patients with DCI who underwent definitive closure of the colon during DCL versus patients managed with colostomy with or without DCL. Methods We performed a retrospective chart review of patients with penetrating DCI during 2003–2009. Severity of injury, surgical management, and clinical outcome were assessed. Results Sixty patients with severe gunshot wounds (GSW) and 3 patients with stab wounds were included in the analysis. DCL was required in 30 patients, all with GSW. Three patients died within the first 48 hours, 3 underwent colostomy, and 24 were managed with DA. Thirty-three patients were managed with standard laparotomy: 26 patients with primary anastomosis, and 7 with colostomy. Overall mortality rate was 9.5%. Three late deaths occurred in the DCL group, and only one death was associated with an anastomotic leak. Conclusions Performing a DA in DCI during DCL is a reliable and feasible approach as long as severe acidosis, bowel wall edema, and/or persistent intra-abdominal infections are not present. PMID:22182861

  14. Safety of performing a delayed anastomosis during damage control laparotomy in patients with destructive colon injuries.

    PubMed

    Ordoñez, Carlos A; Pino, Luis F; Badiel, Marisol; Sánchez, Alvaro I; Loaiza, Jhon; Ballestas, Leonardo; Puyana, Juan Carlos

    2011-12-01

    Recent studies report the safety and feasibility of performing delayed anastomosis (DA) in patients undergoing damage control laparotomy (DCL) for destructive colon injuries (DCIs). Despite accumulating experience in both civilian and military trauma, questions regarding how to best identify high-risk patients and minimize the number of anastomosis-associated complications remain. Our current practice is to perform a definitive closure of the colon during DCL, unless there is persistent acidosis, bowel wall edema, or evidence of intra-abdominal abscess. In this study, we evaluated the safety of this approach by comparing outcomes of patients with DCI who underwent definitive closure of the colon during DCL versus patients managed with colostomy with or without DCL. We performed a retrospective chart review of patients with penetrating DCI during 2003 to 2009. Severity of injury, surgical management, and clinical outcome were assessed. Sixty patients with severe gunshot wounds and three patients with stab wounds were included in the analysis. DCL was required in 30 patients, all with gunshot wounds. Three patients died within the first 48 hours, three underwent colostomy, and 24 were managed with DA. Thirty-three patients were managed with standard laparotomy: 26 patients with primary anastomosis and 7 with colostomy. Overall mortality rate was 9.5%. Three late deaths occurred in the DCL group, and only one death was associated with an anastomotic leak. Performing a DA in DCI during DCL is a reliable and feasible approach as long as severe acidosis, bowel wall edema, and/or persistent intra-abdominal infections are not present.

  15. Post-Closure Monitoring Report for Corrective Action Unit 339: Area 12 Fleet Operations Steam Cleaning Effluent Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    K. B. Campbell

    2002-09-01

    The Area 12 Fleet Operations Steam Cleaning Effluent site is located in the southeastern portion of the Area 12 Camp at the Nevada Test Site. This site is identified in the Federal Facility Agreement and Consent Order (1996) as Corrective Action Site (CAS) 12-19-01 and is the only CAS assigned to Corrective Action Unit (CAU) 339. Post-closure sampling and inspection of the site were completed on March 27, 2002. Post-closure monitoring activities were scheduled biennially (every two years) in the Post-Closure Monitoring Plan provided in the Closure Report for CAU 339: Area 12 Fleet Operations Steam Cleaning Effluent, Nevada Testmore » Site (U.S. Department of Energy, Nevada Operations Office [DOEN], 1997). A baseline for the site was established by sampling in 1997. Based on the recommendations from the 1999 post-closure monitoring report (DOE/NV, 1999), samples were collected in 2000, earlier than originally proposed, because the 1999 sample results did not provide the expected decrease in total petroleum hydrocarbon (TPH) concentrations at the site. Sampling results from 2000 (DOE/NV, 2000) and 2001 (DOE/NV, 2001) revealed favorable conditions for natural degradation at the CAU 339 site, but because of differing sample methods and heterogeneity of the soil, data results from 2000 and later were not directly correlated with previous results. Post-closure monitoring activities for 2002 consisted of the following: (1) Soil sample collection from three undisturbed plots (Plots A, B, and C, Figure 2). (2) Sample analysis for TPH as oil and bio-characterization parameters (Comparative Enumeration Assay [CEA] and Standard Nutrient Panel [SNP]). (3) Site inspection to evaluate the condition of the fencing and signs. (4) Preparation and submittal of the Post-Closure Monitoring Report.« less

  16. Evaluation of left ventricular function by tissue Doppler and speckle-derived strain rate echocardiography after percutaneous ductus closure.

    PubMed

    Amoogzar, Hamid; Shakiba, Ali Mohammad; Derakhshan, Dorna; Ajami, Gholamhossein; Cheriki, Sirous; Borzouee, Mohammad; Edraki, Mohammad Reza; Mehdizadegan, Nima

    2015-01-01

    The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P < 0.05). After 1 month, both improved significantly; ultimately, after 1 month no change was observed in systolic function measures compared with the pre-closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P < 0.05). Both early tissue Doppler early velocity of lateral mitral annulus (E'M) and early to late velocity ratio (E'M/A'M) of lateral mitral annulus decreased significantly (P = 0.02) in early post-closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P < 0.001 for both occasions). Global and segmental longitudinal strain measures reduced significantly early after PDA closure (P < 0.05) but it improved remarkably in the subsequent month. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, Thomas; Patterson, Russell; Camphouse, Chris

    There are two primary regulatory requirements for Panel Closures at the Waste Isolation Pilot Plant (WIPP), the nation's only deep geologic repository for defense related Transuranic (TRU) and Mixed TRU waste. The Federal requirement is through 40 CFR 191 and 194, promulgated by the U.S. Environmental Protection Agency (EPA). The state requirement is regulated through the authority of the Secretary of the New Mexico Environment Department (NMED) under the New Mexico Hazardous Waste Act (HWA), New Mexico Statutes Annotated (NMSA) 1978, chap. 74-4-1 through 74-4-14, in accordance with the New Mexico Hazardous Waste Management Regulations (HWMR), 20.4.1 New Mexico Annotatedmore » Code (NMAC). The state regulations are implemented for the operational period of waste emplacement plus 30 years whereas the federal requirements are implemented from the operational period through 10,000 years. The 10,000 year federal requirement is related to the adequate representation of the panel closures in determining long-term performance of the repository. In Condition 1 of the Final Certification Rulemaking for 40 CFR Part 194, the EPA required a specific design for the panel closure system. The U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) has requested, through the Planned Change Request (PCR) process, that the EPA modify Condition 1 via its rulemaking process. The DOE has also requested, through the Permit Modification Request (PMR) process, that the NMED modify the approved panel closure system specified in Permit Attachment G1. The WIPP facility is carved out of a bedded salt formation 655 meters below the surface of southeast New Mexico. Condition 1 of the Final Certification Rulemaking specifies that the waste panels be closed using Option D which is a combination of a Salado mass concrete (SMC) monolith and an isolation/explosion block wall. The Option D design was also accepted as the panel closure of choice by the NMED. After twelve years of waste handling operations and a greater understanding of the waste and the behavior of the underground salt formation, the DOE has established a revised panel closure design. This revised design meets both the short-term NMED Permit requirements for the operational period, and also the Federal requirements for long-term repository performance. This new design is simpler, easier to construct and has less of an adverse impact on waste disposal operations than the originally approved Option D design. The Panel Closure Redesign is based on: (1) the results of in-situ constructability testing performed to determine run-of-mine salt reconsolidation parameters and how the characteristics of the bedded salt formation affect these parameters and, (2) the results of air flow analysis of the new design to determine that the limit for the migration of Volatile Organic Compounds (VOCs) will be met at the compliance point. Waste panel closures comprise a repository feature that has been represented in WIPP performance assessment (PA) since the original Compliance Certification Application of 1996. Panel closures are included in WIPP PA models principally because they are a part of the disposal system, not because they play a substantive role in inhibiting the release of radionuclides to the outside environment. The 1998 rulemaking that certified WIPP to receive transuranic waste placed conditions on the panel closure design to be implemented in the repository. The revised panel closure design, termed the Run-of-Mine (ROM) Panel Closure System (ROMPCS), is comprised of 30.48 meters of ROM salt with barriers at each end. The ROM salt is generated from ongoing mining operations at the WIPP and may be compacted and/or moistened as it is emplaced in a panel entry. The barriers consist of bulkheads, similar to those currently used in the panels as room closures. A WIPP performance assessment has been completed that incorporates the ROMPCS design into the representation of the repository, and compares repository performance to that achieved with the approved Option D design. Several key physical processes and rock mechanics principles are incorporated into the performance assessment. First, creep closure of the salt rock surrounding a panel entry results in consolidation of the ROM salt emplaced in the entry. Eventually, the ROM salt comprising the ROMPCS will approach a condition similar to intact salt. As the ROM salt reaches higher fractional densities during consolidation, back stress will be imposed on the surrounding rock mass leading to eventual healing of the disturbed rock zone above and below the panel closure. Healing of the disturbed rock zone above and below the ROMPCS reduces the porosity and permeability in those areas. Analysis of the new design demonstrates that: (1) the WIPP continues to meet regulatory compliance requirements when the ROMPCS design is implemented instead of Option D, and (2) there is no impact on the short-term effectiveness of the panel closure to limit the concentration of VOCs at the WIPP site boundary to a fraction of the health-based exposure limits (HBLs) during the operational period. (authors)« less

  18. Modeling Fatigue Damage Onset and Progression in Composites Using an Element-Based Virtual Crack Closure Technique Combined With the Floating Node Method

    NASA Technical Reports Server (NTRS)

    De Carvalho, Nelson V.; Krueger, Ronald

    2016-01-01

    A new methodology is proposed to model the onset and propagation of matrix cracks and delaminations in carbon-epoxy composites subject to fatigue loading. An extended interface element, based on the Floating Node Method, is developed to represent delaminations and matrix cracks explicitly in a mesh independent fashion. Crack propagation is determined using an element-based Virtual Crack Closure Technique approach to determine mixed-mode energy release rates, and the Paris-Law relationship to obtain crack growth rate. Crack onset is determined using a stressbased onset criterion coupled with a stress vs. cycle curve and Palmgren-Miner rule to account for fatigue damage accumulation. The approach is implemented in Abaqus/Standard® via the user subroutine functionality. Verification exercises are performed to assess the accuracy and correct implementation of the approach. Finally, it was demonstrated that this approach captured the differences in failure morphology in fatigue for two laminates of identical stiffness, but with layups containing ?deg plies that were either stacked in a single group, or distributed through the laminate thickness.

  19. Percutaneous closure of atrial septal defects leads to normalisation of atrial and ventricular volumes

    PubMed Central

    Teo, Karen SL; Dundon, Benjamin K; Molaee, Payman; Williams, Kerry F; Carbone, Angelo; Brown, Michael A; Worthley, Matthew I; Disney, Patrick J; Sanders, Prashanthan; Worthley, Stephen G

    2008-01-01

    Background Percutaneous closure of atrial septal defects (ASDs) should potentially reduce right heart volumes by removing left-to-right shunting. Due to ventricular interdependence, this may be associated with impaired left ventricular filling and potentially function. Furthermore, atrial changes post-ASD closure have been poorly understood and may be important for understanding risk of atrial arrhythmia post-ASD closure. Cardiovascular magnetic resonance (CMR) is an accurate and reproducible imaging modality for the assessment of cardiac function and volumes. We assessed cardiac volumes pre- and post-percutaneous ASD closure using CMR. Methods Consecutive patients (n = 23) underwent CMR pre- and 6 months post-ASD closure. Steady state free precession cine CMR was performed using contiguous slices in both short and long axis views through the ASD. Data was collected for assessment of left and right atrial, ventricular end diastolic volumes (EDV) and end systolic volumes (ESV). Data is presented as mean ± SD, volumes as mL, and paired t-testing performed between groups. Statistical significance was taken as p < 0.05. Results There was a significant reduction in right ventricular volumes at 6 months post-ASD closure (RVEDV: 208.7 ± 76.7 vs. 140.6 ± 60.4 mL, p < 0.0001) and RVEF was significantly increased (RVEF 35.5 ± 15.5 vs. 42.0 ± 15.2%, p = 0.025). There was a significant increase in the left ventricular volumes (LVEDV 84.8 ± 32.3 vs. 106.3 ± 38.1 mL, p = 0.003 and LVESV 37.4 ± 20.9 vs. 46.8 ± 18.5 mL, p = 0.016). However, there was no significant difference in LVEF and LV mass post-ASD closure. There was a significant reduction in right atrial volumes at 6 months post-ASD closure (pre-closure 110.5 ± 55.7 vs. post-closure 90.7 ± 69.3 mL, p = 0.019). Although there was a trend to a decrease in left atrial volumes post-ASD closure, this was not statistically significant (84.5 ± 34.8 mL to 81.8 ± 44.2 mL, p = NS). Conclusion ASD closure leads to normalisation of ventricular volumes and also a reduction in right atrial volume. Further follow-up is required to assess how this predicts outcomes such as risk of atrial arrhythmias after such procedures. PMID:19040763

  20. The use of a silicon sheet for gradual wound closure after fasciotomy.

    PubMed

    Walker, Tobias; Gruler, Miriam; Ziemer, Gerhard; Bail, Dorothee H L

    2012-06-01

    We present a silicon sheet for temporary wound covering and gradual wound closure after open fasciotomy. Fasciotomy was performed in a total of 70 limbs with compartment syndrome (CS). The main etiology of CS was predominantly vascular. All patients were treated with a silicon sheet to cover the soft tissue defect and gradually reapproximate the skin margins. In 53% of the patients, a delayed final wound closure was achieved after a mean of 11.9 days. This method allows final closure of fasciotomy wounds without scar contractures, marginal necrosis, infection, or significant pain. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  1. Closure of skin incisions in rabbits by laser soldering: I: Wound healing pattern.

    PubMed

    Simhon, David; Brosh, Tamar; Halpern, Marisa; Ravid, Avi; Vasilyev, Tamar; Kariv, Naam; Katzir, Abraham; Nevo, Zvi

    2004-01-01

    Temperature-controlled tissue laser soldering is an innovative sutureless technique awaiting only solid experimental data to become the gold-standard surgical procedure for incision closure. The goals of the current study were: (1) to define the optimal laser soldering conditions, (2) to explore the immediate skin reparative healing events after sealing the wound, and (3) to determine the long-term trajectory of skin wound healing. Skin incisions were generated over rabbit dorsa and were closed using different wound-closure interventions, in three groups: (a) closure, using a temperature-controlled infrared fiberoptic CO2 laser system, employing 47% bovine serum albumin as a solder; (b) wound closure by cyanoacrylate glues; and (c) wound closure by sutures. The reparative outcomes were evaluated macroscopically and microscopically, employing semi-quantitative grading indices. Laser soldering of incisions at T = 65 degrees C emerged as the optimal method achieving immediate wound sealing. This in turn induced accelerated reparative events characterized by a reduced inflammatory reaction, followed by minimal scarring and leading to a fine quality healing. Temperature-controlled laser soldering offers an accelerated wound reparative process with numerous advantages over the conventional methods. Further investigations may reveal additional benefits in the spectrum of advantages that this innovative surgical technology has to offer. This can introduce new scientific insight that will pave the way for clinical use.

  2. Preliminary results of laser tissue welding in extravesical reimplantation of the ureters.

    PubMed

    Kirsch, A J; Dean, G E; Oz, M C; Libutti, S K; Treat, M R; Nowygrod, R; Hensle, T W

    1994-02-01

    One exciting potential use of laparoscopic technology is the extravesical reimplantation of the ureters. We have assessed the efficacy of laser-activated fibrinogen solder to close vesical muscle flaps over submucosal ureters (Lich-Gregoir technique) in a canine model. Four dogs were subjected to unilateral flap closures via a protein solder (indocyanine green and fibrinogen) applied to the bladder serosa and exposed to 808 nm. continuous wave diode laser energy. Contralateral reimplantation was performed using 4-zero vicryl muscle flap closures (controls). At 7, 14 and 28 days postoperatively, intravenous pyelograms confirmed bilateral ureteral patency. At intravesical pressures above 100 cm. H2O, there was no evidence of wound disruption in either group. Nondisrupted wound closures were sectioned and strained until ultimate breakage to determine tensile strength. At each study interval the laser-welded closures withstood greater stress than the controls. Although these data represent single tissue samples and are not amenable to statistical analysis, laser-welded closures appeared to be stronger at each study interval. In conclusion, laser-welded vesical wound closures appear at least as strong as suture closures in the canine model.

  3. Current topics in surgery for multiple ventricular septal defects.

    PubMed

    Yoshimura, Naoki; Fukahara, Kazuaki; Yamashita, Akio; Doki, Yoshinori; Takeuchi, Katsunori; Higuma, Tomonori; Senda, Kazutaka; Toge, Masayoshi; Matsuo, Tatsuro; Nagura, Saori; Aoki, Masaya; Sakata, Kimimasa; Sakai, Mari

    2016-04-01

    In this review article, we describe several topics, including the sandwich technique, the transatrial re-endocardialization technique, the limited apical left ventriculotomy approach and device closure. The sandwich technique was introduced for the closure of muscular ventricular septal defects (VSD) by sandwiching the septum between two felt patches placed in the left and right ventricle. This technique requires neither the transection of muscular trabeculae nor ventriculotomy. Although the sandwich technique has resulted in the improvement of surgical outcomes, cases of postoperative cardiac dysfunction have been reported. Multiple smaller VSDs have been closed with transatrial re-endocardialization. Septal dysfunction may be avoided through this technique, in which the septal trabeculae are approximated in two layers of superficial, endocardial running sutures. Recently, a number of reports have recommended a limited apical left ventriculotomy approach. With this technique, a much shorter incision of around 1 cm at the apex of the left ventricle may be sufficient for achieving the complete closure of apical muscular VSDs. The transcatheter or perventricular device closure of muscular VSDs has increasingly been performed with good results. Although favorable early and mid-term results of device closure have been reported, this method is not always safer or less invasive than surgical closure. Long-term evaluations should be performed to determine whether the right and left ventricular functions are affected by treatment with relatively large devices in the heart.

  4. A Randomized, Controlled Study Comparing Two Standardized Closure Methods of Laparoscopic Port Sites

    PubMed Central

    Chen, Kai; Klapper, Allan S.; Voige, Hayley

    2010-01-01

    Objectives: To compare octyl-cyanoacrylate tissue adhesive (OCT) with the standard suture technique for the closure of laparoscopic port sites. Methods: This was a randomized clinical trial of 40 patients. All participants had 2 lower abdominal ports, with one port closed using OCT while the opposite port was closed with 4-0 monocryl suture. An evaluation of the wound was performed 2 weeks to 4 weeks after surgery. The Hollander Wound Evaluation Scale (HWES, including step-off of borders, contour irregularities, margin separation, edge inversion, excessive distortion, and overall appearance) was used for cosmetic evaluation. Complications, such as erythema, warmth, tenderness, drainage, and wound infection, were evaluated. Analysis of complications was performed using the chi-square test, and cosmetic evaluation including individual components of the HWES was compared with the t test, P<0.05 considered significant. Results: Eighty wounds were evaluated in 40 patients. The number of patients with complications including erythema (1/40 vs. 16/40), tenderness (1/40 vs. 19/40), and drainage (1/40 vs. 9/40) was lower with OCT than with sutures, respectively (all P<0.001). The ports closed with OCT had higher overall HWES, ie, better cosmetic score (5.92±0.05 vs 5.50±0.13) and lower margin separation (1/40 vs. 10/40) but had higher contour irregularity (6/40 vs. 1/40) (all P<0.05). However, skin contour irregularity was significantly better when OCT was applied using fine tissue forceps (P=0.002). Conclusion: Laparoscopic ports closed with OCT had fewer early complications, such as wound erythema, tenderness, and drainage. Ports closed with OCT had a better cosmetic appearance. PMID:21333194

  5. Patient-specific catheter shaping for the minimally invasive closure of the left atrial appendage.

    PubMed

    Graf, Eva C; Ott, Ilka; Praceus, Julian; Bourier, Felix; Lueth, Tim C

    2018-06-01

    The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the implant landing zone. In this paper, a novel preoperative planning system is proposed that allows patient-individual shaping of catheters to facilitate the correct positioning of the catheter sheath by offering a patient-specific catheter shape. Based on preoperative three-dimensional image data, anatomical points and the planned implant position are marked interactively and a patient-specific catheter shape is calculated if the standard catheter is not considered as suitable. An approach to calculate a catheter shape with four bends by maximization of the bending radii is presented. Shaping of the catheter is supported by a bending form that is automatically generated in the planning program and can be directly manufactured by using additive manufacturing methods. The feasibility of the planning and shaping of the catheter could be successfully shown using six data sets. The patient-specific catheters were tested in comparison with standard catheters by physicians on heart models. In four of the six tested models, the participating physicians rated the patient-individual catheters better than the standard catheter. The novel approach for preoperatively planned and shaped patient-specific catheters designed for the minimally invasive closure of the left atrial appendage could be successfully implemented and a feasibility test showed promising results in anatomies that are difficult to access with the standard catheter.

  6. Tulip deformity with Cera atrial septal defect devices: a report of 3 cases.

    PubMed

    Kohli, Vikas

    2015-02-01

    Device closure of secundum atrial septal defect (ASD) is the treatment of choice when anatomy is favourable. Amplatzer device has remained the gold standard for closure of ASD. Cobra deformity is a well-reported problem with devices. Recently, Tulip deformity has been reported in a single case. We report a series of cases where we noted Tulip deformity along with inability to retract the device in the sheath in Cera Lifetech devices. This resulted in prolongation of procedure, excessive fluoroscopic exposure and additional interventional procedures not usually anticipated in ASD device closure. We believe that the problem is due to the stiffness of the device resulting in its inability to be retracted into the sheath. We also report a unique way of retrieving the device.

  7. Jam proof closure assembly for lidded pressure vessels

    DOEpatents

    Cioletti, Olisse C.

    1992-01-01

    An expendable closure assembly is provided for use (in multiple units) with a lockable pressure vessel cover along its rim, such as of an autoclave. This assembly is suited to variable compressive contact and locking with the vessel lid sealing gasket. The closure assembly consists of a thick walled sleeve insert for retention in the under bores fabricated in the cover periphery and the sleeve is provided with internal threading only. A snap serves as a retainer on the underside of the sleeve, locking it into an under bore retention channel. Finally, a standard elongate externally threaded bolt is sized for mating cooperation with the so positioned sleeve, whereby the location of the bolt shaft in the cover bore hole determines its compressive contact on the underlying gasket.

  8. Transcatheter closure of the left atrial appendage: initial experience with the WATCHMAN device

    PubMed Central

    Ding, Jiandong; Zhu, Jian; Lu, Jing; Ding, Xiuxia; Zhang, Xiaoli; Lu, Wenbin; Ao, Mingqiang; Ma, Genshan

    2015-01-01

    Background: Atrial fibrillation (AF) is the most commonly encountered clinical arrhythmia, accounting for approximately one third of hospitalizations for cardiac rhythm disturbance. In patients with non-valvular AF, approximately 90% of thrombi are thought to arise from the left atrial appendage (LAA). Anticoagulation with warfarin has been the mainstay of therapy to reduce stroke risk in these patients; however, it is not without its complications including bleeding and drug interactions. Percutaneous left atrial appendage closure can be an alternative to warfarin treatment in patients with AF at high risk for thromboembolic events and/or bleeding complications. Methods: Patients with atrial fibrillation and CHADSVASc score ≥ 2, not eligible for anticoagulation, were submitted to left atrial appendage closure using the WATCHMAN device. The procedure was performed under general anaesthesia, and was guided by fluoroscopy and transoesophageal echocardiography. Results: Percutaneous LAA closure with the WATCHMAN device was performed in all patients. At 45-day follow-up no recurrent major adverse events and especially no thromboembolic events occurred. Conclusions: Transcatheter closure of the LAA with the WATCHMAN device is generally safe and feasible. Long-term follow-up will further reveal the risk and benefits of this therapy. PMID:26629008

  9. A comparative evaluation of rate of space closure after extraction using E-chain and stretched modules in bimaxillary dentoalveolar protrusion cases.

    PubMed

    Mitra, Rajat; Londhe, S M; Kumar, Prasanna

    2011-04-01

    Aim of this study was to compare the rate of space closure between E-chain mechanics in one side of upper arch and by elastomeric module with ligature wire on the contralateral side in same patient. Thirty bimaxillary dentoalveolar protrusion cases were taken up for comprehensive fixed orthodontic treatment after extraction of all first premolars to retract both upper and lower anterior teeth. After initial alignment and levelling, alginate impressions were made for upper and lower arches and models constructed. In the upper arch model a vernier caliper was used to measure the extraction space in both sides from middle point of distal surface of canine to the middle most point of mesial surface of second premolar. This is the amount of space present before the onset of retraction mechanics. During space closure procedure two different retracting components were applied in right and left sides of each case. On right side elastic chain (E-chain) applied in both upper and lower arches and on left side elastomeric module with steel ligature (0.010") stretched double its diameter fixed in both arches. Both the mechanisms produced approximately 250-300 g of force as measured by a tension gauge. After onset of retraction mechanism all patients were recalled after every six weeks for three visits. In all these three visits modules and E-chains were changed. In all three visits impression was made, models constructed, and the remaining available space was measured by a vernier caliper up to 0.1 mm level variations. Mean value for total space closure in case of E-chain was 2.777 mm whereas in case of module with ligature wire the value increased to 3.017 mm. Mean value for rate of space closure in case of E-chain was 0.2143 mm, whereas in case of module with ligature wire the value increased to 0.2343 mm with a standard deviation of 0.001104 and 0.001194, respectively. The standard deviation for total space closure was 0.1305 for E-chain and 0.1487 for module with ligature wire. Space closure by elastomeric module with ligature wire is better than the E-chain.

  10. Angle assessment by EyeCam, goniophotography, and gonioscopy.

    PubMed

    Baskaran, Mani; Perera, Shamira A; Nongpiur, Monisha E; Tun, Tin A; Park, Judy; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2012-09-01

    To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) and goniophotography in detecting angle closure, using gonioscopy as the reference standard. In this hospital-based, prospective, cross-sectional study, participants underwent gonioscopy by a single observer, and EyeCam imaging and goniophotography by different operators. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. A masked observer categorized the eyes as per the number of closed quadrants, and an eye was classified as having angle closure if there were 2 or more quadrants of closure. Agreement between the methods was analyzed by κ statistic and comparison of area under receiver operating characteristic curves (AUC). Eighty-five participants (85 eyes) were included, the majority of whom were Chinese. Angle closure was detected in 38 eyes (45%) with gonioscopy, 40 eyes (47%) using EyeCam, and 40 eyes (47%) with goniophotography (P=0.69 in both comparisons, McNemar test). The agreement for angle closure diagnosis (by eye) between gonioscopy and the 2 imaging modalities was high (κ=0.86; 95% Confidence Interval (CI), 0.75-0.97), whereas the agreement between EyeCam and goniophotography was not as good (κ=0.72; 95% CI, 0.57-0.87); largely due to lack of agreement in the nasal and temporal quadrants (κ=0.55 to 0.67). The AUC for detecting eyes with gonioscopic angle closure was similar for goniophotography and EyeCam (AUC 0.93, sensitivity=94.7%, specificity=91.5%; P>0.95). EyeCam and goniophotography have similarly high sensitivity and specificity for the detection of gonioscopic angle closure.

  11. Transcatheter closure of patent ductus arteriosus: 11 years of clinical experience in Cipto Mangunkusumo Hospital, Jakarta, Indonesia.

    PubMed

    Djer, Mulyadi M; Saputro, Dimas Dwi; Putra, Sukman Tulus; Idris, Nikmah Salamia

    2015-06-01

    Transcatheter closure of patent ductus arteriosus (PDA) has been suggested to be the standard treatment of PDA. Although, in general, the procedure shows a high successful rate, outcomes may vary among pediatric cardiology centers. To evaluate the effectiveness of transcatheter closure of PDA in Cipto Mangunkusumo Hospital, Jakarta, Indonesia, this was a retrospective study on patients who underwent transcatheter closure of PDA in Cipto Mangunkusumo Hospital during the period of 2002-2013. Hospital registry was reviewed and data about patients' characteristics, PDA severity, procedure, and outcomes were retrieved. There were 298 patients, of whom 90 were males, who underwent transcatheter closure of PDA during the study period. Median age was 3.4 years (1 months-18 years), and median body weight was 12 (3.6-59) kg. The diameter of PDA ranged from 1.1 to 15.4 mm with a median of 3.7 mm. Device could be deployed in all patients, in which most were the Amplatzer ductal occluder (69.8 %) and the remainders were coils. Median fluoroscopy time was 15.4 (1.5-87) min, and procedure time was 76 (30-200) min. Complete closure was achieved in most patients (97.3 %), whereas device migration occurred in a minority (0.3 %) of patients. No major complication occurred during or after the procedure. Transient anemia and bradycardia were found in 3.7 and 1.3 % patients, respectively. Most patients were discharged from the hospital at 1 day after the procedure. Transcatheter closure method is a safe and effective procedure to close PDA.

  12. Positive Catch & Economic Benefits of Periodic Octopus Fishery Closures: Do Effective, Narrowly Targeted Actions ‘Catalyze’ Broader Management?

    PubMed Central

    Oliver, Thomas A.; Oleson, Kirsten L. L.; Ratsimbazafy, Hajanaina; Raberinary, Daniel; Benbow, Sophie; Harris, Alasdair

    2015-01-01

    Overview Eight years of octopus fishery records from southwest Madagascar reveal significant positive impacts from 36 periodic closures on: (a) fishery catches and (b) village fishery income, such that (c) economic benefits from increased landings outweigh costs of foregone catch. Closures covered ~20% of a village’s fished area and lasted 2-7 months. Fishery Catches from Each Closed Site Octopus landings and catch per unit effort (CPUE) significantly increased in the 30 days following a closure’s reopening, relative to the 30 days before a closure (landings: +718%, p<0.0001; CPUE: +87%, p<0.0001; n = 36). Open-access control sites showed no before/after change when they occurred independently of other management (“no ban”, n = 17/36). On the other hand, open-access control sites showed modest catch increases when they extended a 6-week seasonal fishery shutdown (“ban”, n = 19/36). The seasonal fishery shutdown affects the entire region, so confound all potential control sites. Fishery Income in Implementing Villages In villages implementing a closure, octopus fishery income doubled in the 30 days after a closure, relative to 30 days before (+132%, p<0.001, n = 28). Control villages not implementing a closure showed no increase in income after “no ban” closures and modest increases after “ban” closures. Villages did not show a significant decline in income during closure events. Net Economic Benefits from Each Closed Site Landings in closure sites generated more revenue than simulated landings assuming continued open-access fishing at that site (27/36 show positive net earnings; mean +$305/closure; mean +57.7% monthly). Benefits accrued faster than local fishers’ time preferences during 17-27 of the 36 closures. High reported rates of illegal fishing during closures correlated with poor economic performance. Broader Co-Management We discuss the implications of our findings for broader co-management arrangements, particularly for catalyzing more comprehensive management. PMID:26083862

  13. The TopClosure® 3S System, for skin stretching and a secure wound closure.

    PubMed

    Topaz, Moris; Carmel, Narin-Nard; Silberman, Adi; Li, Ming Sen; Li, Yong Zhong

    2012-07-01

    The principle of stretching wound margins for primary wound closure is commonly practiced and used for various skin defects, leading at times to excessive tension and complications during wound closure. Different surgical techniques, skin stretching devices and tissue expanders have been utilized to address this issue. Previously designed skin stretching devices resulted in considerable morbidity. They were invasive by nature and associated with relatively high localized tissue pressure, frequently leading to necrosis, damage and tearing of skin at the wound margins. To assess the clinical effectiveness and performance and, to determine the safety of TopClosure® for gradual, controlled, temporary, noninvasive and invasive applications for skin stretching and secure wound closing, the TopClosure® device was applied to 20 patients for preoperative skin lesion removal and to secure closure of a variety of wound sizes. TopClosure® was reinforced with adhesives, staples and/or surgical sutures, depending on the circumstances of the wound and the surgeon's judgment. TopClosure® was used prior to, during and/or after surgery to reduce tension across wound edges. No significant complications or adverse events were associated with its use. TopClosure® was effectively used for preoperative skin expansion in preparation for dermal resection (e.g., congenital nevi). It aided closure of large wounds involving significant loss of skin and soft tissue by mobilizing skin and subcutaneous tissue, thus avoiding the need for skin grafts or flaps. Following surgery, it was used to secure closure of wounds under tension, thus improving wound aesthetics. A sample case study will be presented. We designed TopClosure®, an innovative device, to modify the currently practiced concept of wound closure by applying minimal stress to the skin, away from damaged wound edges, with flexible force vectors and versatile methods of attachment to the skin, in a noninvasive or invasive manner.

  14. Substantial Impact of School Closure on the Transmission Dynamics during the Pandemic Flu H1N1-2009 in Oita, Japan

    PubMed Central

    2015-01-01

    Background School closure is considered as an effective measure to prevent pandemic influenza. Although Japan has implemented many class, grade, and whole school closures during the early stage of the pandemic 2009, the effectiveness of such a school closure has not been analysed appropriately. In addition, analysis based on evidence or data from a large population has yet to be performed. We evaluated the preventive effect of school closure against the pandemic (H1N1) 2009 and examined efficient strategies of reactive school closure. Materials and Methods Data included daily reports of reactive school closures and the number of infected students in the pandemic in Oita City, Japan. We used a regression model that incorporated a time delay to analyse the daily data of school closure based on a time continuous susceptible-exposed-infected-removed model of infectious disease spread. The delay was due to the time-lag from transmission to case reporting. We simulated the number of students infected daily with and without school closure and evaluated the effectiveness. Results The model with a 3-day delay from transmission to reporting yielded the best fit using R 2 (the coefficient of determination). This result suggests that the recommended period of school closure is more than 4 days. Moreover, the effect of school closure in the simulation of school closure showed the following: the number of infected students decreased by about 24% at its peak, and the number of cumulative infected students decreased by about 8.0%. Conclusions School closure was an effective intervention for mitigating the spread of influenza and should be implemented for more than 4 days. School closure has a remarkable impact on decreasing the number of infected students at the peak, but it does not substantially decrease the total number of infected students. PMID:26669757

  15. 40 CFR 267.112 - What procedures must I follow?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false What procedures must I follow? 267.112 Section 267.112 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES OPERATING UNDER A STANDARDIZED PERMIT Closure § 267.112 What procedures...

  16. Primary closure versus T-tube drainage in laparoscopic common bile duct exploration: a meta-analysis of randomized clinical trials.

    PubMed

    Wu, Xiangsong; Yang, Yong; Dong, Ping; Gu, Jun; Lu, Jianhua; Li, Maolan; Mu, Jiasheng; Wu, Wenguang; Yang, Jiahua; Zhang, Lin; Ding, Qichen; Liu, Yingbin

    2012-08-01

    To compare the safety and effectiveness of primary closure with those of T-tube drainage in laparoscopic common bile duct exploration (LCBDE) for choledocholithiasis. A comprehensive search was performed in the PubMed, EmBase, and Cochrane Library databases. Only randomized controlled trials comparing primary closure with T-tube drainage in LCBDE were considered eligible for this meta-analysis. The analyzed outcome variables included postoperative mortality, overall morbidity, biliary complication rate, biliary leak rate, reoperation, operating time, postoperative hospital stay, time to abdominal drain removal, and retained stone. All calculations and statistical tests were performed using ReviewerManager 5.1.2 software. A total of 295 patients (148 patients with primary closure and 147 patients with T-tube drainage) from three trials were identified and analyzed. No deaths occurred in any of the trials. Primary closure showed significantly better results in terms of morbidity (risk ratio (RR), 0.51; 95% confidence interval (CI), 0.30 to 0.88), biliary complication without a combination of retained stone (RR, 0.44; 95% CI, 0.20 to 0.97), reoperation (RR, 0.16; 95% CI, 0.03 to 0.87), operating time (mean difference (MD), -20.72; 95% CI, -29.59 to -11.85), postoperative hospital stay (MD, -3.24; 95% CI, -3.96 to -2.52), and time to abdominal drainage removal (MD, -0.45; 95% CI, -0.86 to -0.04). Statistically significant differences were not found between the two methods in terms of biliary leak, biliary complication, and retained stones. The current meta-analysis indicates that primary closure of the common bile duct is safer and more effective than T-tube drainage for LCBDE. Therefore, we do not recommend routine performance of T-tube drainage in LCBDE.

  17. Cutaneous Wound Closure Materials: An Overview and Update

    PubMed Central

    Al-Mubarak, Luluah; Al-Haddab, Mohammed

    2013-01-01

    Introduction: On a daily basis, dermasurgeons are faced with different kinds of wounds that have to be closed. With a plethora of skin closure materials currently available, choosing a solution that combines excellent and rapid cosmetic results with practicality and cost-effectiveness can be difficult, if not tricky. Objectives: We aimed to review the available skin closure materials over the past 20 years and the scientific claims behind their effectiveness in repairing various kinds of wounds. Materials and Methods: The two authors independently searched and scrutinised the literature. The search was performed electronically using Pub Med, the Cochrane Database, Google Scholar and Ovid as search engines to find articles concerning skin closure materials written since 1990. Conclusion: Many factors are involved in the choice of skin closure material, including the type and place of the wound, available materials, physician expertise and preferences, and patient age and health. Evidence-based main uses of different skin closure materials are provided to help surgeons choose the appropriate material for different wounds. PMID:24470712

  18. "When the going gets tough, the tough get going": Motivation towards closure and effort investment in the performance of cognitive tasks.

    PubMed

    Sankaran, Sindhuja; Szumowska, Ewa; Kossowska, Małgorzata

    2017-01-01

    Previous studies have demonstrated that the need for closure (NFC), which refers to an individual's aversion toward uncertainty and the desire to quickly reduce it, leads to reluctance to invest effort in judgments and decision making. However, we argue that NFC may lead to either an increase or a decrease in effort depending on the availability of easy vs. difficult means to achieve closure and perceived importance of the task goal. We found that when closure could be achieved via both less and more demanding means, NFC was associated with decreased effort unless the task was perceived as important (Study 1). However, when attaining closure was possible via demanding means only, NFC was associated with increased effort, regardless of the task importance (Study 2). Moreover, NFC was related to choosing a more instrumental strategy for the goal of closure, even if this strategy required effort (Study 3). The results are discussed in the light of cognitive energetics theory.

  19. Options for Closure of the Infected Abdomen

    PubMed Central

    Campbell, Chris A.; Rosenberger, Laura H.; Politano, Amani D.; Davies, Stephen W.; Riccio, Lin M.; Sawyer, Robert G.

    2012-01-01

    Abstract Background The infected abdomen poses substantial challenges to surgeons, and often, both temporary and definitive closure techniques are required. We reviewed the options available to close the abdominal wall defect encountered frequently during and after the management of complicated intra-abdominal infections. Methods A comprehensive review was performed of the techniques and literature on abdominal closure in the setting of intra-abdominal infection. Results Temporary abdominal closure options include the Wittmann Patch, Bogota bag, vacuum-assisted closure (VAC), the AbThera™ device, and synthetic or biologic mesh. Definitive reconstruction has been described with mesh, components separation, and autologous tissue transfer. Conclusion Reconstructing the infected abdomen, both temporarily and definitively, can be accomplished with various techniques, each of which is associated with unique advantages and disadvantages. Appropriate judgment is required to optimize surgical outcomes in these complex cases. PMID:23216525

  20. Mean-field dynamo action in renovating shearing flows.

    PubMed

    Kolekar, Sanved; Subramanian, Kandaswamy; Sridhar, S

    2012-08-01

    We study mean-field dynamo action in renovating flows with finite and nonzero correlation time (τ) in the presence of shear. Previous results obtained when shear was absent are generalized to the case with shear. The question of whether the mean magnetic field can grow in the presence of shear and nonhelical turbulence, as seen in numerical simulations, is examined. We show in a general manner that, if the motions are strictly nonhelical, then such mean-field dynamo action is not possible. This result is not limited to low (fluid or magnetic) Reynolds numbers nor does it use any closure approximation; it only assumes that the flow renovates itself after each time interval τ. Specifying to a particular form of the renovating flow with helicity, we recover the standard dispersion relation of the α(2)Ω dynamo, in the small τ or large wavelength limit. Thus mean fields grow even in the presence of rapidly growing fluctuations, surprisingly, in a manner predicted by the standard quasilinear closure, even though such a closure is not strictly justified. Our work also suggests the possibility of obtaining mean-field dynamo growth in the presence of helicity fluctuations, although having a coherent helicity will be more efficient.

  1. Sizing of patent ductus arteriosus in adults for transcatheter closure using the balloon pull-through technique.

    PubMed

    Shafi, Nabil A; Singh, Gagan D; Smith, Thomas W; Rogers, Jason H

    2018-05-01

    To describe a novel balloon sizing technique used during adult transcatheter patent ductus arteriosus (PDA) closure. In addition, to determine the clinical and procedural outcomes in six patients who underwent PDA balloon sizing with subsequent deployment of a PDA occluder device. Transcatheter PDA closure in adults has excellent safety and procedural outcomes. However, PDA sizing in adults can be challenging due to variable defect size, high flow state, or anatomical complexity. We describe a series of six cases where the balloon- pull through technique was successfully performed for PDA sizing prior to transcatheter closure. Consecutive adult patients undergoing adult PDA closure at our institution were studied retrospectively. A partially inflated sizing balloon was pulled through the defect from the aorta into the pulmonary artery and the balloon waist diameter was measured. Procedural success and clinical outcomes were obtained. Six adult patients underwent successful balloon pull-through technique for PDA sizing during transcatheter PDA closure, since conventional angiography often gave suboptimal opacification of the defect. All PDAs were treated with closure devices based on balloon PDA sizing with complete closure and no complications. In three patients that underwent preprocedure computed tomography, the balloon size matched the CT derived measurements. The balloon pull-through technique for PDA sizing is a safe and accurate sizing modality in adults undergoing transcatheter PDA closure. © 2017 Wiley Periodicals, Inc.

  2. Evaluation of the Momentum Closure Schemes in MPAS-Ocean

    NASA Astrophysics Data System (ADS)

    Zhao, Shimei; Liu, Yudi; Liu, Wei

    2018-04-01

    In order to compare and evaluate the performances of the Laplacian viscosity closure, the biharmonic viscosity closure, and the Leith closure momentum schemes in the MPAS-Ocean model, a variety of physical quantities, such as the relative reference potential energy (RPE) change, the RPE time change rate (RPETCR), the grid Reynolds number, the root mean square (RMS) of kinetic energy, and the spectra of kinetic energy and enstrophy, are calculated on the basis of results of a 3D baroclinic periodic channel. Results indicate that: 1) The RPETCR demonstrates a saturation phenomenon in baroclinic eddy tests. The critical grid Reynolds number corresponding to RPETCR saturation differs between the three closures: the largest value is in the biharmonic viscosity closure, followed by that in the Laplacian viscosity closure, and that in the Leith closure is the smallest. 2) All three closures can effectively suppress spurious dianeutral mixing by reducing the grid Reynolds number under sub-saturation conditions of the RPETCR, but they can also damage certain physical processes. Generally, the damage to the rotation process is greater than that to the advection process. 3) The dissipation in the biharmonic viscosity closure is strongly dependent on scales. Most dissipation concentrates on small scales, and the energy of small-scale eddies is often transferred to large-scale kinetic energy. The viscous dissipation in the Laplacian viscosity closure is the strongest on various scales, followed by that in the Leith closure. Note that part of the small-scale kinetic energy is also transferred to large-scale kinetic energy in the Leith closure. 4) The characteristic length scale L and the dimensionless parameter D in the Leith closure are inherently coupled. The RPETCR is inversely proportional to the product of D and L. When the product of D and L is constant, both the simulated RPETCR and the inhibition of spurious dianeutral mixing are the same in all tests using the Leith closure. The dissipative scale in the Leith closure depends on the parameter L, and the dissipative intensity depends on the parameter D. 5) Although optimal results may not be achieved by using the optimal parameters obtained from the 2D barotropic model in the 3D baroclinic simulation, the total energies are dissipative in all three closures. Dissipation is the strongest in the biharmonic viscosity closure, followed by that in the Leith closure, and that in the Laplacian viscosity closure is the weakest. Mesoscale eddies develop the fastest in the biharmonic viscosity closure after the baroclinic adjustment process finishes, and the kinetic energy reaches its maximum, which is attributed to the smallest dissipation of enstrophy in the biharmonic viscosity closure. Mesoscale eddies develop the slowest, and the kinetic energy peak value is the smallest in the Laplacian viscosity closure. Results in the Leith closure are between that in the biharmonic viscosity closure and the Laplacian viscosity closure.

  3. 9 CFR 318.301 - Containers and closures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Section 318.301 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... examinations for rigid containers (cans)—(1) Visual examinations. A closure technician shall visually examine... container shall be examined for product leakage or obvious defects. A visual examination shall be performed...

  4. Pan-nitinol occluder and special delivery device for closure of patent ductus arteriosus: a canine-model feasibility study.

    PubMed

    Jiang, Hai-bin; Bai, Yuan; Zong, Gang-jun; Han, Lin; Li, Wei-ping; Lu, Yang; Qin, Yong-wen; Zhao, Xian-xian

    2013-01-01

    The aim of this study was to evaluate a new type of occluder for patent ductus arteriosus. Patent ductus arteriosus was established in a canine model by anastomosing a length of autologous jugular vein to the descending aorta and the left pulmonary artery in an end-to-side fashion. Transcatheter closure of each patent ductus arteriosus was performed on 10 dogs, which were then monitored for as long as 6 months with aortography, echocardiography, and histologic evaluation. Transcatheter closure with use of the novel pan-nitinol device was successful in all canine models. Postoperative echocardiography showed that the location and shape of the occluders were normal, without any residual shunting. Further histologic evaluation confirmed that the occluder surface was completely endothelialized 3 months after implantation. Transcatheter patent ductus arteriosus closure with the pan-nitinol occluder can be performed safely and successfully in a canine model and shows good biological compatibility and low mortality rates.

  5. An alternative assessment of second-order closure models in turbulent shear flows

    NASA Technical Reports Server (NTRS)

    Speziale, Charles G.; Gatski, Thomas B.

    1994-01-01

    The performance of three recently proposed second-order closure models is tested in benchmark turbulent shear flows. Both homogeneous shear flow and the log-layer of an equilibrium turbulent boundary layer are considered for this purpose. An objective analysis of the results leads to an assessment of these models that stands in contrast to that recently published by other authors. A variety of pitfalls in the formulation and testing of second-order closure models are uncovered by this analysis.

  6. Analytic closures for M1 neutrino transport

    DOE PAGES

    Murchikova, E. M.; Abdikamalov, E.; Urbatsch, T.

    2017-04-25

    Carefully accounting for neutrino transport is an essential component of many astrophysical studies. Solving the full transport equation is too expensive for most realistic applications, especially those involving multiple spatial dimensions. For such cases, resorting to approximations is often the only viable option for obtaining solutions. One such approximation, which recently became popular, is the M1 method. It utilizes the system of the lowest two moments of the transport equation and closes the system with an ad hoc closure relation. The accuracy of the M1 solution depends on the quality of the closure. Several closures have been proposed in themore » literature and have been used in various studies. We carry out an extensive study of these closures by comparing the results of M1 calculations with precise Monte Carlo calculations of the radiation field around spherically symmetric protoneutron star models. We find that no closure performs consistently better or worse than others in all cases. The level of accuracy that a given closure yields depends on the matter configuration, neutrino type and neutrino energy. As a result, given this limitation, the maximum entropy closure by Minerbo on average yields relatively accurate results in the broadest set of cases considered in this work.« less

  7. Interferometric Imaging Directly with Closure Phases and Closure Amplitudes

    NASA Astrophysics Data System (ADS)

    Chael, Andrew A.; Johnson, Michael D.; Bouman, Katherine L.; Blackburn, Lindy L.; Akiyama, Kazunori; Narayan, Ramesh

    2018-04-01

    Interferometric imaging now achieves angular resolutions as fine as ∼10 μas, probing scales that are inaccessible to single telescopes. Traditional synthesis imaging methods require calibrated visibilities; however, interferometric calibration is challenging, especially at high frequencies. Nevertheless, most studies present only a single image of their data after a process of “self-calibration,” an iterative procedure where the initial image and calibration assumptions can significantly influence the final image. We present a method for efficient interferometric imaging directly using only closure amplitudes and closure phases, which are immune to station-based calibration errors. Closure-only imaging provides results that are as noncommittal as possible and allows for reconstructing an image independently from separate amplitude and phase self-calibration. While closure-only imaging eliminates some image information (e.g., the total image flux density and the image centroid), this information can be recovered through a small number of additional constraints. We demonstrate that closure-only imaging can produce high-fidelity results, even for sparse arrays such as the Event Horizon Telescope, and that the resulting images are independent of the level of systematic amplitude error. We apply closure imaging to VLBA and ALMA data and show that it is capable of matching or exceeding the performance of traditional self-calibration and CLEAN for these data sets.

  8. Congenital heart surgery: expected versus observed surgical performance according to the Aristotle complexity score.

    PubMed

    Photiadis, J; Sinzobahamvya, N; Arenz, C; Sata, S; Haun, C; Schindler, E; Asfour, B; Hraska, V

    2011-08-01

    The Aristotle score quantifies the complexity involved in congenital heart surgery. It defines surgical performance as complexity score times hospital survival. We studied how expected and observed surgical performance evolved over time. 2312 main procedures carried out between 2006 and 2010 were analyzed. The Aristotle basic score, corresponding hospital survival and related observed surgical performance were estimated. Expected survival was based on the mortality risks published by O'Brien and coauthors. Observed performance divided by expected performance was called the standardized ratio of performance. This should trend towards a figure above 100%. Survival rates and performance are given with 95% confidence intervals. The mean Aristotle basic score was 7.88 ± 2.68. 51 patients died: observed hospital survival was 97.8 % (97.1 %-98.3%). 115 deaths were anticipated: expected survival was 95.2% (93.5%-96.3%). Observed and expected surgical performance reached 7.71 (7.65-7.75) and 7.49 (7.37-7.59), respectively. Therefore the overall standardized ratio of performance was 102.94%. The ratio increased from 2006 (ratio = 101.60%) to 2009 (103.92%) and was 103.42% in 2010. Performance was high for the repair of congenital corrected transposition of the great arteries and ventricular septal defect (VSD) by atrial switch and Rastelli procedure, the Norwood procedure, repair of truncus arteriosus, aortic arch repair and VSD closure, and the Ross-Konno procedure, with corresponding standardized ratios of 123.30%, 116.83%, 112.99%, 110.86% and 110.38%, respectively. With a ratio of 82.87%, performance was low for repair of Ebstein's anomaly. The standardized ratio of surgical performance integrates three factors into a single value: procedure complexity, postoperative observed survival, and comparison with expected survival. It constitutes an excellent instrument for quality monitoring of congenital heart surgery programs over time. It allows an accurate comparison of surgical performance across institutions with different case mixes. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Anterior Segment Imaging Predicts Incident Gonioscopic Angle Closure.

    PubMed

    Baskaran, Mani; Iyer, Jayant V; Narayanaswamy, Arun K; He, Yingke; Sakata, Lisandro M; Wu, Renyi; Liu, Dianna; Nongpiur, Monisha E; Friedman, David S; Aung, Tin

    2015-12-01

    To investigate the incidence of gonioscopic angle closure after 4 years in subjects with gonioscopically open angles but varying degrees of angle closure detected on anterior segment optical coherence tomography (AS OCT; Visante; Carl Zeiss Meditec, Dublin, CA) at baseline. Prospective, observational study. Three hundred forty-two subjects, mostly Chinese, 50 years of age or older, were recruited, of whom 65 were controls with open angles on gonioscopy and AS OCT at baseline, and 277 were cases with baseline open angles on gonioscopy but closed angles (1-4 quadrants) on AS OCT scans. All subjects underwent gonioscopy and AS OCT at baseline (horizontal and vertical single scans) and after 4 years. The examiner performing gonioscopy was masked to the baseline and AS OCT data. Angle closure in a quadrant was defined as nonvisibility of the posterior trabecular meshwork by gonioscopy and visible iridotrabecular contact beyond the scleral spur in AS OCT scans. Gonioscopic angle closure in 2 or 3 quadrants after 4 years. There were no statistically significant differences in age, ethnicity, or gender between cases and controls. None of the control subjects demonstrated gonioscopic angle closure after 4 years. Forty-eight of the 277 subjects (17.3%; 95% confidence interval [CI], 12.8-23; P < 0.0001) with at least 1 quadrant of angle closure on AS OCT at baseline demonstrated gonioscopic angle closure in 2 or more quadrants, whereas 28 subjects (10.1%; 95% CI, 6.7-14.6; P < 0.004) demonstrated gonioscopic angle closure in 3 or more quadrants after 4 years. Individuals with more quadrants of angle closure on baseline AS OCT scans had a greater likelihood of gonioscopic angle closure developing after 4 years (P < 0.0001, chi-square test for trend for both definitions of angle closure). Anterior segment OCT imaging at baseline predicts incident gonioscopic angle closure after 4 years among subjects who have gonioscopically open angles and iridotrabecular contact on AS OCT at baseline. Copyright © 2015 American Academy of Ophthalmology. All rights reserved.

  10. Evaluation of high-performance fiber-reinforced concrete for bridge deck connections, closure pours, and joints : final report.

    DOT National Transportation Integrated Search

    2017-01-01

    Connections, closure pours, and joints in bridges are often sources of distress because of cracks and openings. Wide separation facilitates the penetration of harmful solutions that can lead to costly repairs. Cracks are caused by volumetric changes ...

  11. Evaluation of innovative devices to control traffic entering from low-volume access points within a land closure.

    DOT National Transportation Integrated Search

    2014-04-01

    This report describes the methodology and results of analyses performed to identify and evaluate : alternative methods to control traffic entering a lane closure on a two-lane, two-way road from low-volume : access points. Researchers documented the ...

  12. Age-dependent modulation of the somatosensory network upon eye closure.

    PubMed

    Brodoehl, Stefan; Klingner, Carsten; Witte, Otto W

    2016-02-01

    Eye closure even in complete darkness can improve somatosensory perception by switching the brain to a uni-sensory processing mode. This causes an increased information flow between the thalamus and the somatosensory cortex while decreasing modulation by the visual cortex. Previous work suggests that these modulations are age-dependent and that the benefit in somatosensory performance due to eye closing diminishes with age. The cause of this age-dependency and to what extent somatosensory processing is involved remains unclear. Therefore, we intended to characterize the underlying age-dependent modifications in the interaction and connectivity of different sensory networks caused by eye closure. We performed functional MR-imaging with tactile stimulation of the right hand under the conditions of opened and closed eyes in healthy young and elderly participants. Conditional Granger causality analysis was performed to assess the somatosensory and visual networks, including the thalamus. Independent of age, eye closure improved the information transfer from the thalamus to and within the somatosensory cortex. However, beyond that, we found an age-dependent recruitment strategy. Whereas young participants were characterized by an optimized information flow within the relays of the somatosensory network, elderly participants revealed a stronger modulatory influence of the visual network upon the somatosensory cortex. Our results demonstrate that the modulation of the somatosensory and visual networks by eye closure diminishes with age and that the dominance of the visual system is more pronounced in the aging brain. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Annual Report, Fall 2016: Identifying Cost Effective Tank Waste Characterization Approaches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reboul, S. H.; DiPrete, D. P.

    2016-12-12

    This report documents the activities that were performed during the second year of a project undertaken to improve the cost effectiveness and timeliness of SRNL’s tank closure characterization practices. The activities performed during the first year of the project were previously reported in SRNL-STI-2015-00144. The scope of the second year activities was divided into the following three primary tasks: 1) develop a technical basis and strategy for improving the cost effectiveness and schedule of SRNL’s tank closure characterization program; 2) initiate the design and assembly of a new waste removal system for improving the throughput and reducing the personnel dosemore » associated with extraction chromatography radiochemical separations; and 3) develop and perform feasibility testing of three alternative radiochemical separation protocols holding promise for improving high resource demand/time consuming tank closure sample analysis methods.« less

  14. Ischaemic stroke with patent foramen ovale.

    PubMed

    Jusufovic, Mirza; Thomassen, Lars; Skjelland, Mona

    2014-01-28

    There is no sound scientific documentation of current guidelines for the treatment of cerebral infarction assumed to be due to patent foramen ovale. In this article, we present a young patient with this condition. In addition, we provide a general overview of the prevalence, recommended assessment and indications for treatment of patent foramen ovale in ischaemic stroke patients. The article is based on a non-systematic search in PubMed. We emphasise three recently published randomised trials on the subject. Transoesophageal echocardiography with saline contrast is the gold standard for detecting patent foramen ovale. Just who will benefit from the diagnosis and treatment of this condition remains unclear, however. None of the three randomised studies of antithrombotic treatment versus transcatheter closure in patients who have suffered ischaemic stroke show a difference in outcomes, but subgroup analyses indicate that closure in young patients (age <50 years) with a large foramen ovale reduces the number of recurrent ischaemic events. Two other randomised studies of antithrombotic treatment alone versus closure are presently ongoing. For stroke patients with patent foramen ovale, the choice between lifelong antithrombotic therapy alone and transcatheter closure is a difficult one. Treatment with antiplatelet agents remains the first choice in most cases. Well-designed studies are needed to identify which patients will benefit most from closure.

  15. Multidisciplinary management of patent foramen ovale (PFO) and cryptogenic stroke/TIA

    PubMed Central

    Mirzada, Naqibullah; Ladenvall, Per; Hansson, Per-Olof; Eriksson, Peter; Dellborg, Mikael

    2013-01-01

    Purpose Patent foramen ovale (PFO) has been implicated as a risk factor for cryptogenic ischemic stroke (CS). However, there is still a lack of widely accepted, undisputed indications for PFO closure. The present study describes the concept of the multidisciplinary PFO conference and a decision making process for closure versus no closure that was developed into a formalized clinical algorithm, and presents the results of implementing these, in terms of number and proportion of PFO closures as well as repeat referrals. Design Five specialists in neurology, cardiology, internal medicine, thromboembolism, and echocardiography evaluated the clinical data of 311 patients at PFO conferences during 2006 to 2009. The main criteria for closure were patients with first-ever CS with PFO and atrial septal aneurysm, or patients with recurrent CS and PFO without atrial septal aneurysm. Results A total of 143 patients (46%) were accepted for closure and 167 patients were rejected. Patients accepted for closure were younger (mean 50 years versus 58 years) (P < 0.001). The acceptance rate for PFO closure was similar throughout these years, with an average of 45%. Three of 167 patients (1.8%) initially rejected for PFO closure were re-referred due to recurrent stroke, and the PFO closure was subsequently performed. Conclusion The acceptance rate of less than 50% in the present study underscores the complex relationship between CS and PFO. Whatever the criteria used for PFO closure, any unit caring for these patients needs to have a rigorous process to avoid overtreatment as well as undertreatment and to ensure that personal preferences and economic incentives do not steer the selection process. Our algorithm provides a stable acceptance rate and a low rate of repeat referrals. PMID:24082787

  16. Modeling and Simulating Passenger Behavior for a Station Closure in a Rail Transit Network

    PubMed Central

    Yin, Haodong; Han, Baoming; Li, Dewei; Wu, Jianjun; Sun, Huijun

    2016-01-01

    A station closure is an abnormal operational situation in which the entrances or exits of a rail transit station have to be closed for some time due to an unexpected incident. A novel approach is developed to estimate the impacts of the alternative station closure scenarios on both passenger behavioral choices at the individual level and passenger demand at the disaggregate level in a rail transit network. Therefore, the contributions of this study are two-fold: (1) A basic passenger behavior optimization model is mathematically constructed based on 0–1 integer programming to describe passengers’ responses to alternative origin station closure scenarios and destination station closure scenarios; this model also considers the availability of multi-mode transportation and the uncertain duration of the station closure; (2) An integrated solution algorithm based on the passenger simulation is developed to solve the proposed model and to estimate the effects of a station closure on passenger demand in a rail transit network. Furthermore, 13 groups of numerical experiments based on the Beijing rail transit network are performed as case studies with 2,074,267 records of smart card data. The comparisons of the model outputs and the manual survey show that the accuracy of our proposed behavior optimization model is approximately 80%. The results also show that our model can be used to capture the passenger behavior and to quantitatively estimate the effects of alternative closure scenarios on passenger flow demand for the rail transit network. Moreover, the closure duration and its overestimation greatly influence the individual behavioral choices of the affected passengers and the passenger demand. Furthermore, if the rail transit operator can more accurately estimate the closure duration (namely, as g approaches 1), the impact of the closure can be somewhat mitigated. PMID:27935963

  17. Modeling and Simulating Passenger Behavior for a Station Closure in a Rail Transit Network.

    PubMed

    Yin, Haodong; Han, Baoming; Li, Dewei; Wu, Jianjun; Sun, Huijun

    2016-01-01

    A station closure is an abnormal operational situation in which the entrances or exits of a rail transit station have to be closed for some time due to an unexpected incident. A novel approach is developed to estimate the impacts of the alternative station closure scenarios on both passenger behavioral choices at the individual level and passenger demand at the disaggregate level in a rail transit network. Therefore, the contributions of this study are two-fold: (1) A basic passenger behavior optimization model is mathematically constructed based on 0-1 integer programming to describe passengers' responses to alternative origin station closure scenarios and destination station closure scenarios; this model also considers the availability of multi-mode transportation and the uncertain duration of the station closure; (2) An integrated solution algorithm based on the passenger simulation is developed to solve the proposed model and to estimate the effects of a station closure on passenger demand in a rail transit network. Furthermore, 13 groups of numerical experiments based on the Beijing rail transit network are performed as case studies with 2,074,267 records of smart card data. The comparisons of the model outputs and the manual survey show that the accuracy of our proposed behavior optimization model is approximately 80%. The results also show that our model can be used to capture the passenger behavior and to quantitatively estimate the effects of alternative closure scenarios on passenger flow demand for the rail transit network. Moreover, the closure duration and its overestimation greatly influence the individual behavioral choices of the affected passengers and the passenger demand. Furthermore, if the rail transit operator can more accurately estimate the closure duration (namely, as g approaches 1), the impact of the closure can be somewhat mitigated.

  18. Cost comparison of transcatheter and operative closures of ostium secundum atrial septal defects

    PubMed Central

    O’Byrne, Michael L.; Gillespie, Matthew J.; Shinohara, Russell T.; Dori, Yoav; Rome, Jonathan J.; Glatz, Andrew C.

    2015-01-01

    Background Clinical outcomes for transcatheter and operative closures of atrial septal defects (ASDs) are similar. Economic cost for each method has not been well described. Methods A single-center retrospective cohort study of children and adults <30 years of age undergoing closure for single secundum ASD from January 1, 2007, to April 1, 2012, was performed to measure differences in inflation-adjusted cost of operative and transcatheter closures of ASD. A propensity score weight-adjusted multivariate regression model was used in an intention-to-treat analysis. Costs for reintervention and crossover admissions were included in primary analysis. Results A total of 244 subjects were included in the study (64% transcatheter and 36% operative), of which 2% (n = 5) were ≥18 years. Crossover rate from transcatheter to operative group was 3%. Risk of reintervention (P = .66) and 30-day mortality (P = .37) were not significantly different. In a multivariate model, adjusted cost of operative closure was 2012 US $60,992 versus 2012 US $55,841 for transcatheter closure (P < .001). Components of total cost favoring transcatheter closure were length of stay, medications, and follow-up radiologic and laboratory testing, overcoming higher costs of procedure and echocardiography. Professional costs did not differ. The rate of 30-day readmission was greater in the operative cohort, further increasing the cost advantage of transcatheter closure. Sensitivity analyses demonstrated that costs of follow-up visits influenced relative cost but that device closure remained favorable over a broad range of crossover and reintervention rates. Conclusion For single secundum ASD, cost comparison analysis favors transcatheter closure over the short term. The cost of follow-up regimens influences the cost advantage of transcatheter closure. PMID:25965721

  19. Open abdomen treatment for septic patients with gastrointestinal fistula: from fistula control to definitive closure.

    PubMed

    Ren, Jianan; Yuan, Yujie; Zhao, Yunzhao; Gu, Guosheng; Wang, Gefei; Chen, Jun; Fan, Chaogang; Wang, Xinbo; Li, Jieshou

    2014-04-01

    The use of open abdomen in the management of gastrointestinal fistula complicated with severe intra-abdominal infection is uncommon. This study was designed to evaluate outcomes of our staged approach for the infected open abdomen. Patients who had gastrointestinal fistula and underwent open abdomen treatment were retrospectively reviewed. Various materials such as polypropylene mesh and a modified sandwich package were used to achieve temporary abdominal closure followed by skin grafting when the granulation bed matured. A delayed definitive operation was performed for final abdominal closure without implant of prosthetic mesh. Between 1999 and 2009, 56 (68.3%) of 82 patients survived through this treatment. Among them, 42 patients achieved final abdominal closure. Spontaneous fistula closure occurred in 16 patients with secondary fistula recorded in six patients. Besides, wound complications occurred in 13 patients with two cases for pulmonary infection. Within a 12-month follow-up period after definitive closure, no additional fistula was recorded excluding planned ventral hernia repair. Open abdomen treatment was effective for gastrointestinal fistula complicated by severe intra-abdominal infection. A delayed and deliberate operative strategy aiming at fistula excision and fascial closure, with simultaneous abdominal wall reconstruction, was required for the infected open abdomen.

  20. Composite three-layer closure of oral antral communication with 10 months follow-up-a case study.

    PubMed

    Weinstock, Robert J; Nikoyan, Levon; Dym, Harry

    2014-02-01

    We propose a 3-layer composite closure technique for an oral antral communication (OAC) while avoiding secondary donor site morbidity. A patient had developed a 1-cm OAC after extraction of right maxillary first molar. The patient subsequently developed acute maxillary sinusitis. The patient was taken to the operating room, and a Caldwell-Luc procedure was performed. The bony window from the Caldwell-Luc was "press fit" over the bony OAC defect. Soft tissue closure was then achieved with a buccal fat pad flap and a buccal mucosal advancement flap. The patient was examined on postoperative day 5 and 1, 2, 3, 6, and 10 months postoperatively. The acute sinusitis had resolved. The soft tissue closure was successful. The bone graft remained intact, prevented sinus pneumatization, and restored continuity to the floor of the maxillary sinus. The presented technique for 3-layer closure of OACs allows for the stability of a double-layer closure of OAC with the added benefit of bone grafting from single operative site, achieving stable oral antral closure, bone grafting, and the avoidance of secondary donor site morbidity. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Unstrained and strained flamelets for LES of premixed combustion

    NASA Astrophysics Data System (ADS)

    Langella, Ivan; Swaminathan, Nedunchezhian

    2016-05-01

    The unstrained and strained flamelet closures for filtered reaction rate in large eddy simulation (LES) of premixed flames are studied. The required sub-grid scale (SGS) PDF in these closures is presumed using the Beta function. The relative performances of these closures are assessed by comparing numerical results from large eddy simulations of piloted Bunsen flames of stoichiometric methane-air mixture with experimental measurements. The strained flamelets closure is observed to underestimate the burn rate and thus the reactive scalars mass fractions are under-predicted with an over-prediction of fuel mass fraction compared with the unstrained flamelet closure. The physical reasons for this relative behaviour are discussed. The results of unstrained flamelet closure compare well with experimental data. The SGS variance of the progress variable required for the presumed PDF is obtained by solving its transport equation. An order of magnitude analysis of this equation suggests that the commonly used algebraic model obtained by balancing source and sink in this transport equation does not hold. This algebraic model is shown to underestimate the SGS variance substantially and the implications of this variance model for the filtered reaction rate closures are highlighted.

  2. A method and the results of loop colostomy.

    PubMed

    Browning, G G; Parks, A G

    1983-04-01

    A technique of loop colostomy which avoids a sutured skin wound, employs a deep tension suture with retained polythene sleeve as a bridge, and permits routine use of standard terminal colostomy appliances is described. The clinical results in 51 patients are reported and the advantages of this method of construction discussed. All patients were able to use standard, terminal colostomy appliances routinely from the time of construction. There were no immediate postoperative complications. Delayed complications occurred in 5 (10 per cent) patients. Intraperitoneal closure was performed in 43 patients and was complicated by 1 (2.3 per cent) transient fecal leak and 4 (9.3 per cent) would infections. The absence of a sutured skin wound, the small bridge size, and the circular shape of the stoma facilitate use of accurately fitting, standard terminal colostomy appliances rather than the usual loop colostomy apparatus. This results in an improved skin seal, reduced fecal leakage, easier nursing and stoma care, and better patient morale.

  3. Tympanoplasty for Chronic Tympanic Membrane Perforation in Children: Systematic Review and Meta-analysis.

    PubMed

    Hardman, John; Muzaffar, Jameel; Nankivell, Paul; Coulson, Chris

    2015-06-01

    To study the effectiveness of Type 1 tympanoplasty for chronic tympanic membrane perforations in the pediatric age group and to investigate factors influencing its success. Searches were conducted of the MEDLINE database and the Cochrane Database of Systematic Reviews using terms focused around tympanoplasty and children. Searches were performed on June 23, 2014 and limited to English language entries since January 1, 1997. Studies reporting tympanoplasty closure rates in children 18 years and younger, with a minimum follow-up of 6 months, were included. Studies focusing on more advanced forms of tympanoplasty and revision surgery were excluded. Five hundred sixty-four articles were screened identifying 2,609 cases from 45 eligible studies. Data were collected by consensus of the first two authors with the third author arbitrating disparities of opinion. Success was taken as the closure rate at 12 months where possible. Forest plots with Mantel-Haenszel analyses were used to compare closure rates with respect to perforation size, adenoidectomy, status of contralateral ear, Eustachian tube function, active infection, and graft position. Linear regression and Fisher's exact were used to analyze closure rate with respect to age. The mean weighted closure rate for pediatric tympanoplasty was 83.4%. Subgroup analysis found age not to be a significant factor affecting the closure rate. Tympanoplasties performed on larger perforations or in children with abnormal contralateral ear findings were more likely to fail. Surgery may be best delayed until contralateral otitis media with effusion has settled.

  4. Corporate social responsibility for regional sustainability after mine closure: a case study of mining company in Indonesia

    NASA Astrophysics Data System (ADS)

    Syarif, Andi Erwin; Hatori, Tsuyoshi

    2017-06-01

    Creating a soft-landing path for mine closure is key to the sustainability of the mining region. In this research, we presents a case of mine closure in Soroako, a small mining town in the north-east of South Sulawesi province, in the center of Sulawesi Island in Indonesia. Especially we investigates corporate social responsibility (CSR) programs of a mining company, PT Vale Indonesia Tbk (PTVI), towards a soft-landing of mine closure in this region. The data of the CSR programs are gathered from in-depth interviews, the annual reports and managerial reports. Furthermore we presents an integrated view of CSR to close mining in a sustainable manner. We then evaluate CSR strategies of the company and its performance from this viewpoint. Based on these steps, the way to improve the CSR mine closure scenario for enhancing the regional sustainability is discussed and recommended.

  5. A reliable and safe gastrotomy closure technique assessed in a porcine survival model pilot study: success of the Queen's closure.

    PubMed

    Hookey, L C; Bielawska, B; Samis, A; Jalink, D; Ellis, R; Khokhotva, V; Hurlbut, D; Mercer, D

    2009-06-01

    The evolution of NOTES to clinical implementation has been hampered by lack of a reliable, safe, and easy-to-implement technique for closure of the opening created in accessing the peritoneum. The Queen's closure uses a combination of endoscopic clips and loop devices to seal such defects in the stomach wall. This study aimed to assess the Queen's closure in a porcine survival model. Five 30-kg pigs underwent endoscopic transgastric surgery with exploration of the peritoneum. The endoscope was then withdrawn back into the stomach and the closure performed. The animals were recovered, monitored closely, and underwent endoscopy 1 week after surgery. They were then euthanized at 2 (n = 2) and 3 (n = 3) weeks after surgery with subsequent necropsy. The mean procedure time (from intubation of the esophagus to withdrawal of the endoscope) was 79 minutes (range 45-105 minutes) with a mean time of exploration of the peritoneum of 14 minutes (range 8-25 minutes). All animals recovered well with no apparent pain, distress, or signs of infection. Endoscopic examination 1 week after surgery revealed all the closures to be intact and only identifiable by a small ulcer. At necropsy, the gastrotomy site was identifiable only by minor serosal adhesions. Histological study demonstrated full-thickness closure with minimal inflammation. The Queen's closure is a reliable and safe technique that provides full-thickness gastrotomy closure without any observed complications. The technique has proven to be transferable knowledge that holds promise for clinical implementation.

  6. Arrhythmias after transcatheter closure of perimembranous ventricular septal defects with a modified double-disk occluder: early and long-term results.

    PubMed

    Li, Pan; Zhao, Xian-xian; Zheng, Xing; Qin, Yong-wen

    2012-07-01

    With the development of interventional techniques and devices, transcatheter closure of perimembranous ventricular septal defect has been widely performed. However, there has been a lack of long-term follow-up results about postoperative ECG changes of PmVSD patients. We report our experience of early and late arrhythmias after transcatheter closure of PmVSD with a modified double-disk occluder (MDVO). We performed a retrospective review of 79 patients (47 males, 32 females) between September 2002 and May 2007 who underwent transcatheter closure of perimembranous ventricular septal defect. Symmetric and asymmetric PmVSD occluders were used. The diameter of the evaluated defects ranged from 3 to 12 mm, as measured by TTE and 3 to 15 mm by left ventriculography. Most cases of PmVSD were treated successfully with a single procedure, resulting in a successful closure rate of 97% (77/79 patients). There was no death in any of the patients. After the operation, 79 patients were followed-up for a range of 10-76 months (35.3 ± 17.4 months). In this series, 11 cases of incomplete right bundle branch block and five cases of complete right bundle branch block occurred during the early period after operation. During long-term follow-up, these issues declined in prevalence to five and four cases, respectively. Moreover, reversible third-degree AVB occurred during closure or after the procedure, and two of the three patients with reversible AVB received a temporary heart pacemaker implantation. These patients recovered 1 h, 6 days, and 9 days later, respectively. During 10-76 months of follow-up, no complications occurred in any of the patients, including residual shunt, severe aortic valve, or tricuspid valve regurgitation. Device closure of perimembranous ventricular septal defects with a modified double-disk occluder (MDVO) resulted in excellent closure rates and acceptably low arrhythmia rates.

  7. The effect of tourniquet and knee position during wound closure after total knee arthroplasty on early recovery of range of motion: a prospective, randomized study.

    PubMed

    Şükür, Erhan; Öztürkmen, Yusuf; Akman, Yunus Emre; Senel, Ahmet; Azboy, İbrahim

    2016-12-01

    There is no consensus on the position of the knee joint while performing wound closure after total knee arthroplasty (TKA). Further, there are no studies focusing on the association between early functional outcomes and different wound closure strategies. Therefore, we investigated the effects of tourniquet and knee position during wound closure on early recovery of range of motion (ROM) after primary TKA. To our knowledge, this is the first study to evaluate the influence of both tourniquet and knee position during wound closure in primary TKA. One hundred-twenty eligible patients were consecutively enrolled in this study and randomly divided into four groups according to wound closure strategy. Wound closure was either performed with the knee in flexion at 90° or in full extension, with the combination of an inflated or deflated tourniquet. Visual analogue score (VAS), knee ROM, ROM recovery, knee society score (KSS), and wound complications were evaluated in the early postoperative period. After the first postoperative week, ROM recovery in the group with knee in extension and inflated tourniquet was significantly lesser than the two groups with deflated tourniquets. Between the first and fourth postoperative weeks, ROM recovery in the group with knee inflection and deflated tourniquet was significantly higher than the two groups with knee in extension. After the first postoperative week, the visual analog score (VAS) for pain in the group with knee inflection and deflated tourniquet was significantly lesser than the two groups with inflated tourniquets. The differences in the outcomes between the four groups were not significant after the fourth postoperative week. The incidence of wound complications and KSS were not significantly different between the four groups. Following TKA, wound closure with the knee in flexion and after deflating the tourniquet significantly decreased postoperative pain and promoted the recovery of ROM in the early postoperative period.

  8. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bruckheimer, Elchanan, E-mail: elchananb@bezeqint.net; Dagan, Tamir; Atar, Eli

    2013-12-15

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by {approx}50 %. Recatheterization was performed approximately 3 months later. If the portal pressuremore » was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 {+-} 11.3 to 10.8 {+-} 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 {+-} 0.5 to 4.0 {+-} 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 {+-} 53.6 to 65.7 {+-} 9.6 {mu}mol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.« less

  9. Staged transcatheter treatment of portal hypoplasia and congenital portosystemic shunts in children.

    PubMed

    Bruckheimer, Elchanan; Dagan, Tamir; Atar, Eli; Schwartz, Michael; Kachko, Ludmila; Superina, Riccardo; Amir, Gabriel; Shapiro, Rivka; Birk, Einat

    2013-12-01

    Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by ~50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 ± 11.3 to 10.8 ± 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 ± 0.5 to 4.0 ± 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 ± 53.6 to 65.7 ± 9.6 μmol/L; p = 0.002) with no complications. Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.

  10. Computations of turbulent lean premixed combustion using conditional moment closure

    NASA Astrophysics Data System (ADS)

    Amzin, Shokri; Swaminathan, Nedunchezhian

    2013-12-01

    Conditional Moment Closure (CMC) is a suitable method for predicting scalars such as carbon monoxide with slow chemical time scales in turbulent combustion. Although this method has been successfully applied to non-premixed combustion, its application to lean premixed combustion is rare. In this study the CMC method is used to compute piloted lean premixed combustion in a distributed combustion regime. The conditional scalar dissipation rate of the conditioning scalar, the progress variable, is closed using an algebraic model and turbulence is modelled using the standard k-ɛ model. The conditional mean reaction rate is closed using a first order CMC closure with the GRI-3.0 chemical mechanism to represent the chemical kinetics of methane oxidation. The PDF of the progress variable is obtained using a presumed shape with the Beta function. The computed results are compared with the experimental measurements and earlier computations using the transported PDF approach. The results show reasonable agreement with the experimental measurements and are consistent with the transported PDF computations. When the compounded effects of shear-turbulence and flame are strong, second order closures may be required for the CMC.

  11. Skull Base Cerebrospinal Fluid Leakage Control with a Fibrin-Based Composite Tissue Adhesive

    PubMed Central

    Rock, Jack P.; Sierra, David H.; Castro-Moure, Frederico; Jiang, Feng

    1996-01-01

    Cerebrospinal fluid (CSF) leaks can be responsible for significant patient morbidity and mortality. While the majority of leaks induced after head trauma will seal without intervention, spontaneous or surgically-induced leaks often require operative repair. Many modifications on standard surgical technique are available for repair of CSF fistulae, but none assures adequate closure. We have studied the efficacy of a novel fibrin-based composite tissue adhesive (CTA) for closure of experimentally-induced CSF leaks in rats. Fistulae were created in two groups of animals. Two weeks after creation of the leaks, the animals were sacrificed and analyzed for persistence of leak. A 58% leakage rate was noted in the control group (n = 12), and no leaks were noted in the experimental group closed after application of CTA to the surgical defect followed by skin closure (n = 11). Comparing the control group to the experimental group, results were statistically significant (p = 0.015). These data suggest that CTA may be effective as an adjunct for the closure of CSF fistulae. ImagesFigure 2Figure 3 PMID:17170969

  12. Accuracy of GPS time transfer verified by closure around the world

    NASA Technical Reports Server (NTRS)

    Lewandowski, Wlodimierz W.; Petit, Gerard; Thomas, Claudine

    1992-01-01

    The precision of time transfer over intercontinental distances by the Global Positioning System common-view method, using measurements of ionospheric delays, precise ephemerides provided by the Defense Mapping Agency (DMA) and a consistent set of antenna coordinates, reaches 3 to 4 ns for a single 13-minute measurement, and decreases to 2 ns when averaging several measurements over the period of one day. It is thought that even this level of precision can be bettered by improving the ionospheric measurements, the ephemerides of satellites, and the antenna coordinates. In the same conditions, an estimation of the accuracy is attained by using three intercontinental links encircling the Earth to establish a closure condition; the three independent links should add to zero. We have computed such a closure condition over a period of 13 months using data recorded at the Paris Observatory, at the Communications Research Laboratory in Tokyo, and at the National Institute for Standards and Technology in Boulder, Colorado. The closure condition is verified to within a few nanoseconds, but a bias, varying with time, can be detected.

  13. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder.

    PubMed

    Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng

    2012-11-01

    Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective.

  14. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder

    PubMed Central

    Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng

    2012-01-01

    OBJECTIVE: Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS: We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. RESULTS: Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. CONCLUSION: Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective. PMID:23184204

  15. Vacuum assisted closure for the treatment of sternal wounds: the bridge between débridement and definitive closure.

    PubMed

    Song, David H; Wu, Liza C; Lohman, Robert F; Gottlieb, Lawrence J; Franczyk, Mieczyslawa

    2003-01-01

    A method to refine the treatment of sternal wounds using Vacuum Assisted Closure (V.A.C.) therapy as the bridge between débridement and delayed definitive closure is described. A retrospective review of 35 consecutive patients with sternal wound complications over a 2-year period (March of 1999 to March of 2001) was performed. The treatment of sternal wounds with traditional twice-a-day dressing changes was compared with the treatment with the wound V.A.C. device. An analysis of the number of days between initial débridement and closure, number of dressing changes, number and types of flaps needed for reconstruction, and complications was performed. Eighteen patients were treated with traditional twice-a-day dressing changes and 17 patients were treated with V.A.C. therapy alone. The two groups were similar regarding age, sex, type of cardiac procedure, and type of sternal wound. The V.A.C. therapy group had a trend toward a shorter interval between débridement and closure, with a mean of 6.2 days, whereas the dressing change group had mean of 8.5 days. The V.A.C. therapy group had a significantly lower number of dressing changes, with a mean of three, whereas the twice-a-day dressing change group had a mean of 17 (p < 0.05). Reconstruction required an average of 1.5 soft-tissue flaps per patient treated with traditional dressing changes versus 0.9 soft-tissue flaps per patient for those treated with V.A.C. therapy (p < 0.05). Before closure, there was one death among patients undergoing dressing changes and three in the V.A.C. therapy group, all of which were unrelated to the management of the sternal wound. Patients with sternal wounds who have benefited from V.A.C. therapy alone have a significant decrease in the number of dressing changes and number of soft-tissue flaps needed for closure. Finally, the V.A.C. therapy group had a trend toward a decreased number of days between débridement and closure.

  16. Intracardiac Echocardiography for Structural Heart and Electrophysiological Interventions.

    PubMed

    Basman, Craig; Parmar, Yuvrajsinh J; Kronzon, Itzhak

    2017-09-06

    With an increasing number of interventional procedures performed for structural heart disease and cardiac arrhythmias each year, echocardiographic guidance is necessary for safe and efficient results. The purpose of this review article is to overview the principles of intracardiac echocardiography (ICE) and describes the peri-interventional role of ICE in a variety of structural heart disease and electrophysiological interventions. Both transthoracic (TTE) and transesophageal echocardiography have limitations. ICE provides the advantage of imaging from within the heart, providing shorter image distances and higher resolution. ICE may be performed without sedation and avoids esophageal intubation as with transesophageal echocardiography (TEE). Limitations of ICE include the need for additional venous access with possibility of vascular complications, potentially higher costs, and a learning curve for new operators. Data supports the use of ICE in guiding device closure of interatrial shunts, transseptal puncture, and electrophysiologic procedures. This paper reviews the more recent reports that ICE may be used for primary guidance or as a supplement to TEE in patients undergoing left atrial appendage (LAA) closure, interatrial shunt closure, transaortic valve implantation (TAVI), percutaneous mitral valve repair (PMVR), paravalvular leak (PVL) closure, aortic interventions, transcatheter pulmonary valve replacement (tPVR), ventricular septal defect (VSD), and patent ductus arteriosus (PDA) closure. ICE imaging technology will continue to expand and help improve structural heart and electrophysiology interventions.

  17. Laser tissue melding: use of 1.32-μm computerized Nd:YAG laser, results of leak/burst strength studies in microsurgical procedures

    NASA Astrophysics Data System (ADS)

    Anderson, Dallas W.; Hsu, Tung M.; Halpern, Steven J.; Honaker, Arnold

    1993-07-01

    The ProClosureTM System (PCS) consists of a low power 1.32micrometers Nd:YAG laser coupled to a handheld disposable fiber optic device. The system has been designed to perform a wide range of tissue welding applications such as cosmetic skin closure,vascular surgery, and minimally invasive surgical procedures normally performed with sutures and staples. Utilizing a wavelength for tissue fusion that is least distracted by medium in the surgical field coupled with a computerized delivery system allows for a more precise application (+/- 5%) of laser energy to the tissue. The study design involved the micro-surgical anastomosis of twenty Sprague-Dawley rats (vas deferens) and twenty-one Sprague-Dawley rats (femoral arteries). Each rat is its own contralateral control. Laser repair time is approximately one-third that of conventional suturing. Postoperative dissection and burst strength testing was conducted at day 0, 1, 7, and 14. At each postoperative interval, the mean leak/burst strength for laser-assisted closure v. control, was markedly higher. The precise application of energy fluence resulting from ProClosure's computerized system yields an initial strength and a fluid static seal that is superior to conventional suture closure.

  18. Evaluation of Container Closure System Integrity for Frozen Storage Drug Products.

    PubMed

    Nieto, Alejandra; Roehl, Holger; Brown, Helen; Nikoloff, Jonas; Adler, Michael; Mahler, Hanns-Christian

    2016-01-01

    Sometimes, drug product for parenteral administration is stored in a frozen state (e.g., -20 °C or -80 °C), particularly during early stages of development of some biotech molecules in order to provide sufficient stability. Shipment of frozen product could potentially be performed in the frozen state, yet possibly at different temperatures, for example, using dry ice (-80 °C). Container closure systems of drug products usually consist of a glass vial, rubber stopper, and an aluminum crimped cap. In the frozen state, the glass transition temperature (Tg) of commonly used rubber stoppers is between -55 and -65 °C. Below their Tg, rubber stoppers are known to lose their elastic properties and become brittle, and thus potentially fail to maintain container closure integrity in the frozen state. Leaks during frozen temperature storage and transportation are likely to be transient, yet, can possibly risk container closure integrity and lead to microbial contamination. After thawing, the rubber stopper is supposed to re-seal the container closure system. Given the transient nature of the possible impact on container closure integrity in the frozen state, typical container closure integrity testing methods (used at room temperature conditions) are unable to evaluate and thus confirm container closure integrity in the frozen state. Here we present the development of a novel method (thermal physical container closure integrity) for direct assessment of container closure integrity by a physical method (physical container closure integrity) at frozen conditions, using a modified He leakage test. In this study, different container closure systems were evaluated with regard to physical container closure integrity in the frozen state to assess the suitability of vial/stopper combinations and were compared to a gas headspace method. In summary, the thermal physical container closure integrity He leakage method was more sensitive in detecting physical container closure integrity impact than gas headspace and aided identification of an unsuitable container closure system. Sometimes, drug product for parenteral administration is stored in a frozen state (e.g., -20 °C or -80 °C), particularly during early stages of development of some biotech molecules in order to provide sufficient stability. Container closure systems for drug products usually consist of a glass vial, rubber stopper, and an aluminum crimped cap. In the frozen state, the glass transition temperature (Tg) of commonly used rubber stoppers is between -55 and -65 °C. Leaks during frozen temperature storage and transportation are likely to be transient, yet they can possibly risk container closure integrity and lead to microbial contamination and sterility breach. After thawing, the rubber stopper is expected to re-seal the container closure system. Given the transient nature of the possible impact on container closure integrity in the frozen state, typical container closure integrity testing methods (used at room temperature conditions) are unable to evaluate and thus confirm container closure integrity in the frozen state. Here we present the development of a novel method (thermal container closure integrity) for direct measurement of container closure integrity by a physical method (physical container closure integrity) at frozen conditions, using a modified He leakage test. In this study, we found that the thermal container closure integrity He leakage method was more sensitive in detecting physical container closure integrity impact than gas headspace and aided identification of an unsuitable container closure system. © PDA, Inc. 2016.

  19. Transverse mucoperiosteal flap inset by rotation for cleft palate repair: technique and outcomes.

    PubMed

    Black, Jonathan S; Gampper, Thomas J

    2014-01-01

    Cleft palate is a relatively common deformity with various techniques described for its repair. Most techniques address the hard palate portion of the cleft with bilateral mucoperiosteal flaps transposed to the midline. This results in superimposed, linear closure layers directly over the cleft and may predispose the repair to oronasal fistula formation. This report details an alternative technique of flap rotation with an outcome analysis. A retrospective chart analysis was performed of all patients having undergone primary palatoplasty for cleft palate. Demographics and cleft Veau type were recorded. Postoperative speech outcomes were assessed by standardized speech evaluation performed by 2 speech language pathologists. The presence and location of oronasal fistulae was assessed and recorded by the surgeon and speech language pathologists in follow-up evaluations. The study revealed an overall incidence of velopharyngeal insufficiency of 5.7% using this surgical technique. It also revealed a fistula rate of 8.6%. Secondary surgery has been successful in those patients in which it was indicated. Eleven (31%) patients were diagnosed with Robin sequence. This technique demonstrates excellent early outcomes in a difficult subset of cleft patients including a high proportion of those with Pierre Robin sequence. The technique addresses the inherent disadvantages to a linear closure over the bony cleft. The variability in its design provides the surgeon another option for correction of this deformity.

  20. Device-less patent foramen ovale closure by radiofrequency thermal energy.

    PubMed

    Walpoth, Nazan B; Habermacher, Kathrin; Moarof, Igal; Watson, Sandy; Wahl, Andreas; Windecker, Stephan; Schönenberger, Christa; Meier, Bernhard

    2008-02-23

    The goal of this study was to assess the feasibility, safety and success of a system which uses radiofrequency energy (RFE) rather than a device for percutaneous closure of patent foramen ovale (PFO). Sixteen patients (10 men, 6 women, mean age 50 years) were included in the study. All of them had a proven PFO with documented right-to-left shunt (RLS) after Valsalva manoeuvre (VM) during transoesophageal echocardiography (TEE). The patients had an average PFO diameter of 6 +/- 2 mm at TEE and an average of 23 +/- 4 microembolic signals (MES) in power M-mode transcranial Doppler sonography (pm-TCD), measured over the middle cerebral artery. An atrial septal aneurysm (ASA) was present in 7 patients (44%). Balloon measurement, performed in all patients, revealed a stretched PFO diameter of 8 +/- 3 mm. In 2 patients (stretched diameter 11 and 14 mm respectively, both with ASA >10 mm), radiofrequency was not applied (PFO too large) and the PFO was closed with an Amplatzer PFO occluder instead. A 6-month follow-up TEE was performed in all patients. There were no serious adverse events during the procedure or at follow-up (12 months average). TEE 6 months after the first RFE procedure showed complete closure of the PFO in 50% of the patients (7/14). Closure appeared to be influenced by PFO diameter, complete closure being achieved in 89% (7/8) with a balloon-stretched diameter < or =7 mm but in none of the patients >7 mm. Only one of the complete closure patients had an ASA. Of the remainder, 4 (29%) had an ASA. Although the PFO was not completely closed in this group, some reduction in the diameter of the PFO and in MES was documented by TEE and pm-TCD with VM. Five of the 7 residual shunt patients received an Amplatzer PFO occluder. Except for one patient with a minimal residual shunt, all showed complete closure of PFO at 6-month follow-up TEE and pm-TCD with VM. The other two refused a closure device. The results confirm that radiofrequency closure of the PFO is safe albeit less efficacious and more complex than device closure. The technique in its current state should not be attempted in patients with a balloon-stretched PFO diameter >7 mm and an ASA.

  1. Environmental Assessment of the Muscatatuck Urban Training Center near Butlerville, Indiana, October and November 2005

    USGS Publications Warehouse

    Risch, Martin R.; Ulberg, Amanda L.; Robinson, Bret A.

    2007-01-01

    Concentrations of constituents detected in these samples were compared with regulatory standards (the Indiana Surface-Water-Quality Standards and Indiana Ground-Water-Quality Standards) and guidance criteria from the Indiana Department of Environmental Management's Risk Integrated System of Closures for contaminated soil and ground water. Standards or criteria were exceeded by 17 constituent concentrations in 11 environmental samples from 5 of the 7 geographic study areas. Standards or criteria were exceeded for 10 constituents: ammonia, arsenic, benzo(a)pyrene, beryllium, chloride, chloroform, copper, lead, sulfate, and zinc.

  2. Common side closure type, but not stapler brand or oversewing, influences side-to-side anastomotic leak rates.

    PubMed

    Fleetwood, V A; Gross, K N; Alex, G C; Cortina, C S; Smolevitz, J B; Sarvepalli, S; Bakhsh, S R; Poirier, J; Myers, J A; Singer, M A; Orkin, B A

    2017-03-01

    Anastomotic leak (AL) increases costs and cancer recurrence. Studies show decreased AL with side-to-side stapled anastomosis (SSA), but none identify risk factors within SSAs. We hypothesized that stapler characteristics and closure technique of the common enterotomy affect AL rates. Retrospective review of bowel SSAs was performed. Data included stapler brand, staple line oversewing, and closure method (handsewn, HC; linear stapler [Barcelona technique], BT; transverse stapler, TX). Primary endpoint was AL. Statistical analysis included Fisher's test and logistic regression. 463 patients were identified, 58.5% BT, 21.2% HC, and 20.3% TX. Covidien staplers comprised 74.9%, Ethicon 18.1%. There were no differences between stapler types (Covidien 5.8%, Ethicon 6.0%). However, AL rates varied by common side closure (BT 3.7% vs. TX 10.6%, p = 0.017), remaining significant on multivariate analysis. Closure method of the common side impacts AL rates. Barcelona technique has fewer leaks than transverse stapled closure. Further prospective evaluation is recommended. Copyright © 2017. Published by Elsevier Inc.

  3. Comparison Of Intake Gate Closure Methods At Lower Granite, Little Goose, Lower Monumental, And Mcnary Dams Using Risk-Based Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gore, Bryan F.; Blackburn, Tyrone R.; Heasler, Patrick G.

    2001-01-19

    The objective of this report is to compare the benefits and costs of modifications proposed for intake gate closure systems at four hydroelectric stations on the Lower Snake and Upper Columbia Rivers in the Walla Walla District that are unable to meet the COE 10-minute closure rule due to the installation of fish screens. The primary benefit of the proposed modifications is to reduce the risk of damage to the station and environs when emergency intake gate closure is required. Consequently, this report presents the results and methodology of an extensive risk analysis performed to assess the reliability of powerhousemore » systems and the costs and timing of potential damages resulting from events requiring emergency intake gate closure. As part of this analysis, the level of protection provided by the nitrogen emergency closure system was also evaluated. The nitrogen system was the basis for the original recommendation to partially disable the intake gate systems. The risk analysis quantifies this protection level.« less

  4. Left Atrial Appendage Closure for Stroke Prevention: Devices, Techniques, and Efficacy.

    PubMed

    Iskandar, Sandia; Vacek, James; Lavu, Madhav; Lakkireddy, Dhanunjaya

    2016-05-01

    Left atrial appendage closure can be performed either surgically or percutaneously. Surgical approaches include direct suture, excision and suture, stapling, and clipping. Percutaneous approaches include endocardial, epicardial, and hybrid endocardial-epicardial techniques. Left atrial appendage anatomy is highly variable and complex; therefore, preprocedural imaging is crucial to determine device selection and sizing, which contribute to procedural success and reduction of complications. Currently, the WATCHMAN is the only device that is approved for left atrial appendage closure in the United States. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Robotic laser tissue welding of sclera using chitosan films.

    PubMed

    Garcia, Pablo; Mines, Michael J; Bower, Kraig S; Hill, J; Menon, J; Tremblay, Eric; Smith, Benjamin

    2009-01-01

    To demonstrate the feasibility of scleral wound closure using a novel adhesive made of chitosan film. Five-millimeter scleral lacerations were created in enucleated pig eyes. Casted chitosan films were sized to 7x7 mm patches. Lacerations were sealed with chitosan film alone (7 eyes) or chitosan film followed by laser irradiation using a near infrared laser (1,455 nm) at 350 mW for 6 minutes (7 eyes). Seven eyes were closed with 9-0 nylon suture for comparison (7 eyes). Outcome measures included watertight closure, closure time, and leak pressure. Leak pressure was measured with a pressure transducer attached to tubing continuously monitored intraocular pressure during saline infusion. Watertight closure testing was performed immediately following closure (n = 3 per group) and after 24 hours (n = 3 per group). One eye in each group was fixed in formalin for histology. All wounds were watertight for each closure method. Mean closure time with unlasered chitosan film was 2.24 minutes (range 1.80-3.26, 7 eyes) with a mean leak pressure of 303 mm Hg (range 217-364, 3 eyes). Mean closure time with lasered chitosan was 12.47 minutes (range 11.45-14.15, 7 eyes) with a mean leak pressure of 454.7 mm Hg (range 152-721, 3 eyes). Suture closure required a mean of 4.83 minutes (range 4.03-7.30, 7 eyes) and resulted in a mean leak pressure of 570.3 mm Hg (range 460-646, 3 eyes). Both lasered and unlasered chitosan eyes remained watertight after 24 hours. Histology revealed minimal laser tissue damage in lasered eyes. In this preliminary study chitosan film successfully closed scleral lacerations with and without the application of laser energy. While laser appears to strengthen the closure, it significantly increases the closure time. Chitosan based adhesives hold promise as a scleral wound closure technique.

  6. Percutaneous closure of patent foramen ovale in patients with presumed paradoxical embolism: periprocedural results and midterm risk of recurrent neurologic events.

    PubMed

    Balbi, Manrico; Casalino, Laura; Gnecco, Giovanni; Bezante, Gian Paolo; Pongiglione, Giacomo; Marasini, Maurizio; Del Sette, Massimo; Barsotti, Antonio

    2008-08-01

    To report our data on selected patients with previous paradoxical embolism who underwent transcatheter patent foramen ovale (PFO) closure. Between July 2001 and July 2007, percutaneous PFO closure was performed on 128 patients (65 women, mean age: 46 +/- 12.8 years). Patent foramen ovale closure was recommended for secondary prevention in patients with previous transient ischemic attacks (52.5%), stroke (46%), or peripheral embolism (1.5%). Implantation was successful in all patients, and at the end of intervention, complete PFO closure was achieved in 70.3% of them. There were no "major" complications (ie, deaths, device embolization or thrombosis, need for cardiac surgery). The overall incidence of complications (mostly hemorrhagic) was 7%. The mean follow-up period was 32 months. Complete closure had been achieved in 78.4% and in 82.5% of patients at the third month of transesophageal echocardiography examination and at the sixth month of transcranial Doppler examination, respectively. There were no recurrent thromboembolic events during the follow-up period. Percutaneous closure of PFO is a feasible procedure, but it is not a risk-free technique. However, in correctly selected patients (ie, large PFO and those at risk for neurologic relapse), nearly complete PFO closure seems to provide protection from future neurologic ischaemic events at midterm follow-up.

  7. Safety and efficacy of excision and direct closure in acute burns surgery: outcome analysis in a prospective series of 100 patients and a survey of UK burns surgeons' attitudes.

    PubMed

    Bain, Charles J; Wang, Tim; McArthur, Gordon; Williams, Greg; Atkins, Joanne; Jones, Isabel

    2014-12-01

    Many burns surgeons avoid excision and direct closure of acute burns owing to concerns over wound dehiscence, scarring and infection. There is no evidence in the literature to support this practice. We present outcomes of a prospective series of 100 patients who underwent excision and direct closure of 138 burns over a 2-year period, along with results from a survey sent to 33 senior burns surgeons to gauge attitudes towards direct closure in burns surgery. 47% of survey respondents never perform direct closure. Dehiscence was cited as the most common concern, followed by hypertrophic scarring (HTS). In our cohort, the superficial dehiscence rate was 12% and the HTS rate was 16%, with no scarring contractures. Patients with healing time greater than 14 days were more likely to develop HTS (p=0.008), as were those with wound dehiscence (p=0.014). Patients undergoing part-grafting in addition to direct closure took significantly longer to heal than those undergoing direct closure alone (p=0.0002), with the donor site or graft delaying healing in the majority. Excision and direct closure of acute burn wounds avoids donor site morbidity and has an acceptable complication rate. It is a safe and effective treatment for full thickness burns in selected cases. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  8. Length and pressure of the reconstructed lower esophageal sphincter is determined by both crural closure and Nissen fundoplication.

    PubMed

    Louie, Brian E; Kapur, Seema; Blitz, Maurice; Farivar, Alexander S; Vallières, Eric; Aye, Ralph W

    2013-02-01

    Laparoscopic Nissen fundoplication is comprised of: a wrap thought responsible for the lower esophageal sphincter function and crural closure performed to prevent herniation. We hypothesized gastroesophageal junction competence effected by Nissen fundoplication results from closure of the crural diaphragm and creation of the fundoplication. Patients with uncomplicated reflux undergoing Nissen fundoplication were prospectively enrolled. After hiatal dissection, patients were randomized to crural closure followed by fundoplication (group 1) or fundoplication followed by crural closure (group 2). Intra-operative high-resolution manometry collected sphincter pressure and length data after complete dissection and after each component repair. Eighteen patients were randomized. When compared to the completely dissected hiatus, the mean sphincter length increased 1.3 cm (p < 0.001), and mean sphincter pressure was increased by 13.7 mmHg (p < 0.001). Groups 1 and 2 had similar sphincter length and pressure changes. Crural closure and fundal wrap contribute equally to sphincter length, although crural closure appears to contribute more to sphincter pressure. The Nissen fundoplication restores the function of the gastroesophageal junction and thus the reflux barrier by means of two main components: the crural closure and the construction of a 360° fundal wrap. Each of these components is equally important in establishing both increased sphincter length and pressure.

  9. Corrective Action Decision Document for Corrective Action Unit 428: Area 3 Septic Waste Systems 1 and 5, Tonopah Test Range, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    U.S. Department of Energy, Nevada Operations Office

    2000-02-08

    This Corrective Action Decision Document identifies and rationalizes the US Department of Energy, Nevada Operations Office's selection of a recommended corrective action alternative (CAA) appropriate to facilitate the closure of Corrective Action Unit (CAU) 428, Septic Waste Systems 1 and 5, under the Federal Facility Agreement and Consent Order. Located in Area 3 at the Tonopah Test Range (TTR) in Nevada, CAU 428 is comprised of two Corrective Action Sites (CASs): (1) CAS 03-05-002-SW01, Septic Waste System 1 and (2) CAS 03-05-002- SW05, Septic Waste System 5. A corrective action investigation performed in 1999 detected analyte concentrations that exceeded preliminarymore » action levels; specifically, contaminants of concern (COCs) included benzo(a) pyrene in a septic tank integrity sample associated with Septic Tank 33-1A of Septic Waste System 1, and arsenic in a soil sample associated with Septic Waste System 5. During this investigation, three Corrective Action Objectives (CAOs) were identified to prevent or mitigate exposure to contents of the septic tanks and distribution box, to subsurface soil containing COCs, and the spread of COCs beyond the CAU. Based on these CAOs, a review of existing data, future use, and current operations in Area 3 of the TTR, three CAAs were developed for consideration: Alternative 1 - No Further Action; Alternative 2 - Closure in Place with Administrative Controls; and Alternative 3 - Clean Closure by Excavation and Disposal. These alternatives were evaluated based on four general corrective action standards and five remedy selection decision factors. Based on the results of the evaluation, the preferred CAA was Alternative 3. This alternative meets all applicable state and federal regulations for closure of the site and will eliminate potential future exposure pathways to the contaminated soils at the Area 3 Septic Waste Systems 1 and 5.« less

  10. Percutaneous closure of the left atrial appendage for prevention of thromboembolism in atrial fibrillation for patients with contraindication to or failure of oral anticoagulation: a single-center experience.

    PubMed

    Faustino, Ana; Paiva, Luís; Providência, Rui; Trigo, Joana; Botelho, Ana; Costa, Marco; Leitão-Marques, António

    2013-06-01

    In non-valvular atrial fibrillation 90% of thrombi originate in the left atrial appendage (LAA). Percutaneous LAA closure has been shown to be non-inferior to warfarin for prevention of thromboembolism. To evaluate the initial experience of a single center in percutaneous LAA closure in patients with high thromboembolic risk and in whom oral anticoagulation was impractical or contraindicated or had failed. Patients with non-valvular atrial fibrillation and CHADS2 score ≥2 in whom oral anticoagulation was impractical or contraindicated or had failed underwent percutaneous LAA closure according to the standard technique. After the procedure, dual antiplatelet therapy was maintained for one month, followed by single antiplatelet therapy indefinitely. Patients were followed by clinical assessment and transthoracic and transesophageal echocardiography. The procedure was performed in 22 of the 23 selected patients (95.7%), mean age 70±9 years, CHADS2 score 3.2±0.9 and CHA2DS2-VASC score 4.7±1.4. Intraprocedural device replacement was necessary only in the first patient, due to oversizing. The following periprocedural complications were observed: one femoral pseudoaneurysm, three femoral hematomas and two minor oropharyngeal bleeds, resolved by local hemostatic measures. During a 12±8 month follow-up a mild peri-device flow and a thrombus adhering to the device, resolved under with enoxaparin therapy, were identified. The rate of transient ischemic attack (TIA)/stroke was lower than expected according to the CHADS2 score (0 vs. 6.7±2.2%). In our initial experience, this procedure proved to be a feasible, safe and effective alternative for atrial fibrillation patients in whom oral anticoagulation is not an option. Only relatively minor complications were observed, with a lower than expected TIA/stroke rate. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  11. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder.

    PubMed

    Bilici, Meki; Demir, Fikri; Akın, Alper; Türe, Mehmet; Balık, Hasan; Kuyumcu, Mahir

    2017-12-01

    The aim of this study was to evaluate the feasibility, efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with the Occlutech duct occluder (ODO) in children. We reviewed the clinical records of 71 patients who underwent percutaneous closure of PDA with an ODO between September 2014 and August 2016. The Occlutech duct occluder was applied to 71 patients during the study period (September 2014-August 2016), and the results were analyzed in this study. Forty-two of the patients were female and 29 male. The median age was 20.5 months (range, 6-194 months) and median weight was 16 kg (range, 6-68 kg). The PDA was classified as type A in 54 patients (76.1%), type E in 14 (19.7%), type C in 2 (2.8%) and type B in 1 (1.4%) based on the Krichenko classification. A standard ODO device was used for the transcatheter closure procedure in 66 patients and the long-shank ODO device in 5. In the echocardiographic measurement of PDA, the median smallest diameter was 2.7 mm (range, 1.5-7.0 mm), and in the angiographic measurement, the median smallest diameter was 2.5 mm (range, 1.5-6.5 mm). All 71 patients underwent successful PDA closure with the ODO. Angiography following the procedure showed complete closure in 47 patients (66.2%), mild residual shunt in 13 patients (18.3%) and a trivial shunt in 11 patients (15.5%). Color flow Doppler echocardiogpaphy at 24 h post-implantation showed that complete closure was achieved in 65 patients (91.5%), and 6 patients (8.5%) had mild residual shunt. All patients (100%) had complete closure at 30 days of follow-up. The results of this study showed that the Occlutech PDA occluder device is safe and effective in the closure of PDA. As the pulmonary artery side of the device is wider than the aortic side, protrusion toward the aortic side and embolization are prevented, but there is residual shunt in the early period, although this residual shunt disappeared after a few months.

  12. Efficacy of stapler versus hand-sewn closure after distal pancreatectomy (DISPACT): a randomised, controlled multicentre trial.

    PubMed

    Diener, Markus K; Seiler, Christoph M; Rossion, Inga; Kleeff, Jörg; Glanemann, Matthias; Butturini, Giovanni; Tomazic, Ales; Bruns, Christiane J; Busch, Olivier R C; Farkas, Stefan; Belyaev, Orlin; Neoptolemos, John P; Halloran, Christopher; Keck, Tobias; Niedergethmann, Marco; Gellert, Klaus; Witzigmann, Helmut; Kollmar, Otto; Langer, Peter; Steger, Ulrich; Neudecker, Jens; Berrevoet, Frederik; Ganzera, Silke; Heiss, Markus M; Luntz, Steffen P; Bruckner, Thomas; Kieser, Meinhard; Büchler, Markus W

    2011-04-30

    The ideal closure technique of the pancreas after distal pancreatectomy is unknown. We postulated that standardised closure with a stapler device would prevent pancreatic fistula more effectively than would a hand-sewn closure of the remnant. This multicentre, randomised, controlled, parallel group-sequential superiority trial was done in 21 European hospitals. Patients with diseases of the pancreatic body and tail undergoing distal pancreatectomy were eligible and were randomly assigned by central randomisation before operation to either stapler or hand-sewn closure of the pancreatic remnant. Surgical performance was assessed with intraoperative photo documentation. The primary endpoint was the combination of pancreatic fistula and death until postoperative day 7. Patients and outcome assessors were masked to group assignment. Interim and final analysis were by intention to treat in all patients in whom a left resection was done. This trial is registered, ISRCTN18452029. Between Nov 16, 2006, and July 3, 2009, 450 patients were randomly assigned to treatment groups (221 stapler; 229 hand-sewn closure), of whom 352 patients (177 stapler, 175 hand-sewn closure) were analysed. Pancreatic fistula rate or mortality did not differ between stapler (56 [32%] of 177) and hand-sewn closure (49 [28%] of 175; OR 0·84, 95% CI 0·53–1·33; p=0·56). One patient died within the fi rst 7 days after surgery in the hand-sewn group; no deaths occurred in the stapler group. Serious adverse events did not differ between groups. Stapler closure did not reduce the rate of pancreatic fistula compared with hand-sewn closure for distal pancreatectomy. New strategies, including innovative surgical techniques, need to be identified to reduce this adverse outcome. German Federal Ministry of Education and Research.

  13. Nonlinear closures for scale separation in supersonic magnetohydrodynamic turbulence

    NASA Astrophysics Data System (ADS)

    Grete, Philipp; Vlaykov, Dimitar G.; Schmidt, Wolfram; Schleicher, Dominik R. G.; Federrath, Christoph

    2015-02-01

    Turbulence in compressible plasma plays a key role in many areas of astrophysics and engineering. The extreme plasma parameters in these environments, e.g. high Reynolds numbers, supersonic and super-Alfvenic flows, however, make direct numerical simulations computationally intractable even for the simplest treatment—magnetohydrodynamics (MHD). To overcome this problem one can use subgrid-scale (SGS) closures—models for the influence of unresolved, subgrid-scales on the resolved ones. In this work we propose and validate a set of constant coefficient closures for the resolved, compressible, ideal MHD equations. The SGS energies are modeled by Smagorinsky-like equilibrium closures. The turbulent stresses and the electromotive force (EMF) are described by expressions that are nonlinear in terms of large scale velocity and magnetic field gradients. To verify the closures we conduct a priori tests over 137 simulation snapshots from two different codes with varying ratios of thermal to magnetic pressure ({{β }p}=0.25,1,2.5,5,25) and sonic Mach numbers ({{M}s}=2,2.5,4). Furthermore, we make a comparison to traditional, phenomenological eddy-viscosity and α -β -γ closures. We find only mediocre performance of the kinetic eddy-viscosity and α -β -γ closures, and that the magnetic eddy-viscosity closure is poorly correlated with the simulation data. Moreover, three of five coefficients of the traditional closures exhibit a significant spread in values. In contrast, our new closures demonstrate consistently high correlations and constant coefficient values over time and over the wide range of parameters tested. Important aspects in compressible MHD turbulence such as the bi-directional energy cascade, turbulent magnetic pressure and proper alignment of the EMF are well described by our new closures.

  14. The Evaluator's Role in Recommending Program Closure: A Model for Decision Making and Professional Responsibility

    ERIC Educational Resources Information Center

    Eddy, Rebecca M.; Berry, Tiffany

    2009-01-01

    Evaluators face challenges when programs consistently fail to meet expectations for performance or improvement and consequently, evaluators may recommend that closing a program is the most prudent course of action. However, the evaluation literature provides little guidance regarding when an evaluator might recommend program closure. Given…

  15. Engineering study for closure of 209E facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brevick, C.H.; Heys, W.H.; Johnson, E.D.

    1997-07-07

    This document is an engineering study for evaluating alternatives to determine the most cost effective closure plan for the 209E Facility, Critical Mass Laboratory. This laboratory is located in the 200 East Area of the Hanford Site and contains a Critical Assembly Room and a Mix room were criticality experiments were once performed.

  16. Combined ionizing radiation and thermal injury in the rat. Evaluation of early excision and closure of the burn wound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirsch, E.F.; Vezina, R.; Corbett, S.

    1990-01-01

    The present study was undertaken to establish an animal model of combined whole-body irradiation and thermal injury and to determine the effectiveness of early excision and closure of the burn wound in such a model. Whole-body irradiation over a range of doses resulted in a predictable mortality rate, with an LD50/30 of 783 rad with 95% confidence limits of 737 and 823 rad. A controlled 10% body surface area full-thickness thermal injury resulted in no deaths in 30 animals. When combined with a standard nonlethal 10% thermal injury, varying doses of whole-body irradiation resulted in widely differing LD50/30 values inmore » three separate cohorts of rats. Excision and closure of a 10% burn 24 hours after exposure to 200 rads did not improve survival.« less

  17. Pediatric lower extremity mower injuries.

    PubMed

    Hill, Sean M; Elwood, Eric T

    2011-09-01

    Lawn mower injuries in children represent an unfortunate common problem to the plastic reconstructive surgeon. There are approximately 68,000 per year reported in the United States. Compounding this problem is the fact that a standard treatment algorithm does not exist. This study follows a series of 7 pediatric patients treated for lower extremity mower injuries by a single plastic surgeon. The extent of soft tissue injury varied. All patients were treated with negative pressure wound therapy as a bridge to definitive closure. Of the 7 patients, 4 required skin grafts, 1 required primary closure, 1 underwent a lower extremity amputation secondary to wounds, and 1 was repaired using a cross-leg flap. Function limitations were minimal for all of our patients after reconstruction. Our basic treatment algorithm is presented with initial debridement followed by the simplest method possible for wound closure using negative pressure wound therapy, if necessary.

  18. CLOSURE REPORT FOR CORRECTIVE ACTION UNIT165: AREA 25 AND 26 DRY WELL AND WASH DOWN AREAS, NEVADA TEST SITE, NEVADA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BECHTEL NEVADA

    This Closure Report (CR) documents the closure activities for Corrective Action Unit (CAU) 165, Area 25 and 26 Dry Well and Washdown Areas, according to the Federal Facility Agreement and Consent Order (FFACO) of 1996. CAU 165 consists of 8 Corrective Action Sites (CASs) located in Areas 25 and 26 of the Nevada Test Site (NTS). The NTS is located approximately 105 kilometers (65 miles) northwest of Las Vegas, nevada. Site closure activities were performed according to the Nevada Division of Environmental Protection (NDEP)-approved Corrective Action Plan (CAP) for CAU 165. CAU 165 consists of the following CASs: (1) CASmore » 25-07-06, Train Decontamination Area; (2) CAS 25-07-07, Vehicle Washdown; (3) CAS 25-20-01, Lab Drain Dry Well; (4) CAS 25-47-01, Reservoir and French Drain; (5) CAS 25-51-02, Drywell; (6) CAS 25-59-01, Septic System; (7) CAS 26-07-01, Vehicle Washdown Station; and (8) CAS 26-59-01, Septic System. CAU 165, Area 25 and 26 Dry Well and Washdown Areas, consists of eight CASs located in Areas 25 and 26 of the NTS. The approved closure alternatives included No Further Action, Clean Closure, and Closure in Place with Administrative Controls.« less

  19. Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.

    PubMed

    Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz

    2015-06-01

    The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.

  20. The modern staged repair of classic bladder exstrophy: a detailed postoperative management strategy for primary bladder closure.

    PubMed

    Stec, Andrew A; Baradaran, Nima; Schaeffer, Anthony; Gearhart, John P; Matthews, Ranjiv I

    2012-10-01

    Successful primary bladder closure of classic bladder exstrophy sets the stage for development of adequate bladder capacity and eventual voided continence. The postoperative pathway following primary bladder closure at the authors' institution is quantitatively and qualitatively detailed. Sixty-five consecutive newborns (47 male) undergoing primary closure of classic bladder exstrophy were identified and data were extracted relating to immediate postoperative care. Overall success rate was utilized to validate the pathway. Mean age at time of primary closure was 4.6 days and mean hospital stay was 35.8 days. Osteotomy was performed in 19 patients (mean age 8.8 days), and was not required in 39 infants (mean age 2.9 days). All patients were immobilized for 4 weeks. Tunneled epidural analgesia was employed in 61/65 patients. All patients had ureteral catheters and a suprapubic tube, along with a comprehensive antibiotic regimen. Postoperative total parenteral nutrition was commonly administered, and enteral feedings started around day 4.6. Our success rate of primary closure was 95.4%. A detailed and regimented plan for bladder drainage, immobilization, pain control, nutrition, antimicrobial prophylaxis, and adequate healing time is a cornerstone for the postoperative management of the primary closure of bladder exstrophy. Copyright © 2011 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  1. Quality assurance in melanoma surgery: The evolving experience at a large tertiary referral centre.

    PubMed

    Read, R L; Pasquali, S; Haydu, L; Thompson, J F; Stretch, J R; Saw, R P M; Quinn, M J; Shannon, K; Spillane, A J

    2015-07-01

    The quality of melanoma surgery needs to be assessed by oncological outcome and complication rates. There is no published consensus on complication rates for common melanoma surgeries, namely wide excision (WE), sentinel node biopsy (SNB) and regional lymph node dissection (RLND). Consequently there are no agreed standards by which surgeons can audit their practices. Surgical standards were proposed in 2008 following review of the literature and from expert opinion. Melanoma Institute Australia (MIA) self-reported audit data from 2011 and 2012 were compared with these standards. To quality check the self-reported audit, RLND data were extracted from the MIA database. Six surgeons performed a mean of 568 surgeries each quarter; with a mean of 106 major procedures. Following WE with primary closure or flap repair, wound infection or dehiscence occurred in <1% of cases. When skin grafting was required non-take of >20% of the grafted area was observed in 5.9% of cases. Following SNB wound infection and significant seroma occurred in 1.8% of cases. RLND node counts were below the 90% standard in 4 of 409 procedures. In comparison, data extraction identified 405 RLNDs, with node counts below the 90% standard in eight procedures. Two of these patients had previously undergone surgery removing nodes from the field and two had gross coalescing disease with extensive extra-nodal spread. The quality standards proposed in 2008 have been validated long-term by high volume caseloads. The data presented provide standards by which melanoma surgeons can audit their surgical performance. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Fenestrated Transcatheter ASD Closure in Adults with Diastolic Dysfunction and/or Pulmonary Hypertension: Case Series and Review of the Literature.

    PubMed

    Abdelkarim, Ayman; Levi, Daniel S; Tran, Bao; Ghobrial, Joanna; Aboulhosn, Jamil

    2016-12-01

    This study aims to evaluate the safety and efficacy of transcatheter fenestrated ASD closure and to summarize the literature regarding the published techniques and outcomes of transcatheter partial ASD closure. Patients with left ventricular diastolic dysfunction (LVDD) or right ventricular (RV) dysfunction and/or pulmonary hypertension (PHT) may suffer untoward consequences of complete closure of an ostium secundum atrial septal defect (ASD). Therefore, for patients that fall under these categories we suggest partial occlusion of the defect, which may be better tolerated than complete defect closure. After obtaining IRB approval, a search for patients that have undergone percutaneous ASD closure was performed in the Ahmanson/UCLA Adult Congenital Heart Disease Center database to identify which patients received a fenestrated ASD closure device. Eight consecutive patients ranging between 22 and 83 years of age (mean 48 years) with PHT and/or LVDD or RV dysfunction who underwent fenestrated transcatheter ASD closure at UCLA were identified. None of the subjects experienced complications related to the procedure. Postprocedure clinical evaluation showed improvement in symptoms and exercise capacity. Available follow-up transthoracic echocardiography data (mean 4 months, range 0-20 months) demonstrated patent fenestrations in four of eight patients. None of the patients had thromboembolic or infectious complications and there were no device migrations, erosions or embolizations. Partial ASD occlusion in patients with diastolic dysfunction or RV dysfunction and/or PHT is safe and may be better tolerated than complete ASD closure in selected patients. © 2016 Wiley Periodicals, Inc.

  3. Comparing Gonioscopy With Visante and Cirrus Optical Coherence Tomography for Anterior Chamber Angle Assessment in Glaucoma Patients.

    PubMed

    Hu, Cindy X; Mantravadi, Anand; Zangalli, Camila; Ali, Mohsin; Faria, Bruno M; Richman, Jesse; Wizov, Sheryl S; Razeghinejad, M Reza; Moster, Marlene R; Katz, L Jay

    2016-02-01

    The aim of this study was to compare gonioscopy with Visante and Cirrus optical coherence tomography (OCT) for identifying angle structures and the presence of angle closure in patients with glaucoma. A secondary objective was to assess interrater agreement for gonioscopy grading among 3 independent examiners. Gonioscopy grading using Spaeth Classification and determination of angle-closure risk was performed on 1 randomly selected eye for 50 phakic patients. Images of the same eye using both Visante and Cirrus OCT were obtained in both light and dark conditions. Agreement of angle closure among 3 devices and interrater agreement for gonioscopy were determined using Cohen's κ (K) or Kendall's coefficient of concordance (W). Of the 50 patients, 60% were female, 64% were white, and the mean age was 62 years. Angle closure was detected in 18%, 16%, and 48% of quadrants with Visante, Cirrus, and gonioscopy, respectively. The scleral spur was identified in 56% and 50% of quadrants with Visante and Cirrus OCT, respectively. Visante and Cirrus OCT showed moderate agreement in detecting angle closure (K=0.42 light, K=0.53 dark) but slight-to-fair agreement with gonioscopy (Visante K=0.25, Cirrus K=0.15). Gonioscopy demonstrated substantial agreement in angle closure (K=0.65 to 0.68) and angle-closure risk assessment (W=0.83) among 3 examiners. Visante and Cirrus OCT imaging may have limited ability to identify angle closure because of difficulty identifying angle structures. Gonioscopy by well-trained clinicians had remarkably consistent agreement for identifying angle-closure risk.

  4. Is there a relationship between wound infections and laceration closure times?

    PubMed Central

    2012-01-01

    Background Lacerations account for a large number of ED visits. Is there a “golden period” beyond which lacerations should not be repaired primarily? What type of relationship exists between time of repair and wound infection rates? Is it linear or exponential? Currently, the influence of laceration age on the risk of infection in simple lacerations repaired is not clearly defined. We conducted this study to determine the influence of time of primary wound closure on the infection rate. Methods This is a prospective observational study of patients who presented to the Emergency Department (ED) with a laceration requiring closure from April 2009 to November 2010. The wound closure time was defined as the time interval from when the patient reported laceration occurred until the time of the start of the wound repair procedure. Univariate analysis was performed to determine the factors predictive of infection. A non-parametric Wilcoxon rank-sum test was performed to compare the median differences of time of laceration repair. Chi-square (Fisher's exact) tests were performed to test for infection differences with regard to gender, race, location of laceration, mechanism of injury, co-morbidities, type of anesthesia and type of suture material used. Results Over the study period, 297 participants met the inclusion criteria and were followed. Of the included participants, 224 (75.4%) were male and 73 (24.6%) were female. Ten patients (3.4%) developed a wound infection. Of these infections, five occurred on hands, four on extremities (not hands) and one on the face. One of these patients was African American, seven were Hispanic and two were Caucasian (p = 0.0005). Median wound closure time in the infection group was 867 min and in the non-infection group 330 min (p = 0.03). Conclusions Without controlling various confounding factors, the median wound closure time for the lacerations in the wound infection group was statistically significantly longer than in the non-infection group. PMID:22835090

  5. Pure natural orifice transluminal endoscopic surgery (NOTES) with ultrasonography-guided transgastric access and over-the-scope-clip closure: a porcine feasibility and survival study.

    PubMed

    Donatsky, Anders Meller; Andersen, Luise; Nielsen, Ole Lerberg; Holzknecht, Barbara Juliane; Vilmann, Peter; Meisner, Søren; Jørgensen, Lars Nannestad; Rosenberg, Jacob

    2012-07-01

    Most natural orifice transluminal endoscopic surgery (NOTES) procedures to date rely on the hybrid technique with simultaneous laparoscopic access to protect against access-related complications and to achieve adequate triangulation for dissection. This is done at the cost of the potential benefits of this new minimally invasive technique. This study aimed to evaluate the feasibility and safety of a transgastric (TG) pure-NOTES procedure in a diagnostic setting. A TG pure-NOTES procedure with endoscopic ultrasonograpy (EUS)-guided access and over-the-scope-clip (OTSC) closure was performed for 10 pigs in a survival and feasibility study. A full macroscopic necropsy with subsequent histologic evaluation was performed on postoperative day (POD) 14. The outcome parameters were uncomplicated follow-up assessment, survival, intraoperative complications, intraabdominal pathology, macroscopic full-thickness closure, and histology-proven full-thickness healing of the gastrotomy. An uncomplicated postoperative course was reported for 9 of the 10 pigs, and survival was reported for all 10 pigs. For all the pigs, EUS-guided access was performed successfully with a median duration of 25 min (range, 12-62 min) and without intraoperative complications or access-related lesions at necropsy. An OTSC closure was achieved with a median duration of 11 min (range, 3-28 min). The OTSC provided immediate closure, but according to the authors' definition of a full-thickness healing evaluated by histologic examination, this was not achieved in any of the cases. Although all the animals survived until POD 14, intraabdominal chronic abscesses were present in 3 of the 10 pigs at necropsy. The EUS-guided TG access proved to be feasible without access-related complications. Although OTSC provided an immediate closure, the histopathology raised concerns regarding the risk of perforation. Together with the high risk of intraabdominal infection, TG pure-NOTES is not yet ready for routine clinical practice.

  6. Development of recommendations for arterial lane closures to optimize traffic operations.

    DOT National Transportation Integrated Search

    2013-01-01

    The 2010 FDOT Design Standards provide information regarding traffic control through work zones at multilane arterials. : However, there are currently no quantitative guidelines for optimizing signal control around work zones. The objective of this :...

  7. 40 CFR 63.961 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission... air emissions to the atmosphere by blocking an opening to the individual drain system. Closure devices...

  8. An Optimal Frequency in Ca2+ Oscillations for Stomatal Closure Is an Emergent Property of Ion Transport in Guard Cells.

    PubMed

    Minguet-Parramona, Carla; Wang, Yizhou; Hills, Adrian; Vialet-Chabrand, Silvere; Griffiths, Howard; Rogers, Simon; Lawson, Tracy; Lew, Virgilio L; Blatt, Michael R

    2016-01-01

    Oscillations in cytosolic-free Ca(2+) concentration ([Ca(2+)]i) have been proposed to encode information that controls stomatal closure. [Ca(2+)]i oscillations with a period near 10 min were previously shown to be optimal for stomatal closure in Arabidopsis (Arabidopsis thaliana), but the studies offered no insight into their origins or mechanisms of encoding to validate a role in signaling. We have used a proven systems modeling platform to investigate these [Ca(2+)]i oscillations and analyze their origins in guard cell homeostasis and membrane transport. The model faithfully reproduced differences in stomatal closure as a function of oscillation frequency with an optimum period near 10 min under standard conditions. Analysis showed that this optimum was one of a range of frequencies that accelerated closure, each arising from a balance of transport and the prevailing ion gradients across the plasma membrane and tonoplast. These interactions emerge from the experimentally derived kinetics encoded in the model for each of the relevant transporters, without the need of any additional signaling component. The resulting frequencies are of sufficient duration to permit substantial changes in [Ca(2+)]i and, with the accompanying oscillations in voltage, drive the K(+) and anion efflux for stomatal closure. Thus, the frequency optima arise from emergent interactions of transport across the membrane system of the guard cell. Rather than encoding information for ion flux, these oscillations are a by-product of the transport activities that determine stomatal aperture. © 2016 American Society of Plant Biologists. All Rights Reserved.

  9. An Optimal Frequency in Ca2+ Oscillations for Stomatal Closure Is an Emergent Property of Ion Transport in Guard Cells1[CC-BY

    PubMed Central

    Minguet-Parramona, Carla; Hills, Adrian; Vialet-Chabrand, Silvere; Griffiths, Howard; Lawson, Tracy; Lew, Virgilio L.; Blatt, Michael R.

    2016-01-01

    Oscillations in cytosolic-free Ca2+ concentration ([Ca2+]i) have been proposed to encode information that controls stomatal closure. [Ca2+]i oscillations with a period near 10 min were previously shown to be optimal for stomatal closure in Arabidopsis (Arabidopsis thaliana), but the studies offered no insight into their origins or mechanisms of encoding to validate a role in signaling. We have used a proven systems modeling platform to investigate these [Ca2+]i oscillations and analyze their origins in guard cell homeostasis and membrane transport. The model faithfully reproduced differences in stomatal closure as a function of oscillation frequency with an optimum period near 10 min under standard conditions. Analysis showed that this optimum was one of a range of frequencies that accelerated closure, each arising from a balance of transport and the prevailing ion gradients across the plasma membrane and tonoplast. These interactions emerge from the experimentally derived kinetics encoded in the model for each of the relevant transporters, without the need of any additional signaling component. The resulting frequencies are of sufficient duration to permit substantial changes in [Ca2+]i and, with the accompanying oscillations in voltage, drive the K+ and anion efflux for stomatal closure. Thus, the frequency optima arise from emergent interactions of transport across the membrane system of the guard cell. Rather than encoding information for ion flux, these oscillations are a by-product of the transport activities that determine stomatal aperture. PMID:26628748

  10. Determination of the Porosity Surfaces of the Disposal Room Containing Various Waste Inventories for WIPP PA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Byoung Yoon; Hansen, Francis D.

    2005-07-01

    This report develops a series of porosity surfaces for the Waste Isolation Pilot Plant. The concept of a porosity surface was developed for performance assessment and comprises calculation of room closure as salt creep processes are mitigated by gas generation and back stress created by the waste packages within the rooms. The physical and mechanical characteristics of the waste packaging that has already been disposed--such as the pipe overpack--and new waste packaging--such as the advanced mixed waste compaction--are appreciably different than the waste form upon which the original compliance was based and approved. This report provides structural analyses of roommore » closure with various waste inventories. All of the underlying assumptions pertaining to the original compliance certification including the same finite element code are implemented; only the material parameters describing the more robust waste packages are changed from the certified baseline. As modeled, the more rigid waste tends to hold open the rooms and create relatively more void space in the underground than identical calculations run on the standard waste packages, which underpin the compliance certification. The several porosity surfaces quantified within this report provide possible ranges of pressure and porosity for performance assessment analyses.3 Intentionally blank4 AcknowledgementsThis research is funded by WIPP programs administered by the U.S. Department of Energy. The authors would like to acknowledge the valuable contributions to this work provided by others. Dr. Joshua S. Stein helped explain the hand off between these finite element porosity surfaces and implementation in the performance calculations. Dr. Leo L. Van Sambeek of RESPEC Inc. helped us understand the concepts of room closure under the circumstances created by a rigid waste inventory. Dr. T. William Thompson and Tom W. Pfeifle provided technical review and Mario J. Chavez provided a Quality Assurance review. The paper has been improved by these individuals.Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94Al850005 Intentionally Blank6« less

  11. Communicating Performance Assessments Results - 13609

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Layton, Mark

    2013-07-01

    The F-Area Tank Farms (FTF) and H-Area Tank Farm (HTF) are owned by the U.S. Department of Energy (DOE) and operated by Savannah River Remediation LLC (SRR), Liquid Waste Operations contractor at DOE's Savannah River Site (SRS). The FTF and HTF are active radioactive waste storage and treatment facilities consisting of 51 carbon steel waste tanks and ancillary equipment such as transfer lines, evaporators and pump tanks. Performance Assessments (PAs) for each Tank Farm have been prepared to support the eventual closure of the underground radioactive waste tanks and ancillary equipment. PAs provide the technical bases and results to bemore » used in subsequent documents to demonstrate compliance with the pertinent requirements for final closure of the Tank Farms. The Tank Farms are subject to a number of regulatory requirements. The State regulates Tank Farm operations through an industrial waste water permit and through a Federal Facility Agreement approved by the State, DOE and the Environmental Protection Agency (EPA). Closure documentation will include State-approved Tank Farm Closure Plans and tank-specific closure modules utilizing information from the PAs. For this reason, the State of South Carolina and the EPA must be involved in the performance assessment review process. The residual material remaining after tank cleaning is also subject to reclassification prior to closure via a waste determination pursuant to Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005. PAs are performance-based, risk-informed analyses of the fate and transport of FTF and HTF residual wastes following final closure of the Tank Farms. Since the PAs serve as the primary risk assessment tools in evaluating readiness for closure, it is vital that PA conclusions be communicated effectively. In the course of developing the FTF and HTF PAs, several lessons learned have emerged regarding communicating PA results. When communicating PA results it is important to stress that the primary goal of the PA results is to provide risk understanding, recognizing the magnitude of risk and identifying the conceptual model decisions and critical assumptions that most impact the results. Conceptual models that describe reality using simplified, mathematical approaches, and their roles in arriving at the PA results, must also be communicated. When presenting PA results, evaluations will typically be focused on a single baseline (or Base Case) to provide a foundation for discussion. The PA results are supplemented by other studies (alternate configurations, uncertainty analyses, and sensitivity analyses) which provide a breadth of modeling to supplement the Base Case. The suite of information offered by the various modeling cases and studies provides confidence that the overall risk is understood along with the underlying parameters and conditions that contribute to risk. (author)« less

  12. An evaluation of abdominal wall closure in general surgical and gynecological residents.

    PubMed

    Williams, Z; Williams, S; Easley, H A; Seita, H M; Hope, W W

    2017-12-01

    To evaluate abdominal wall closure knowledge base and technical skills in surgical and OB/GYN residents. Residents consented to participate in a skills laboratory and quiz. The skills portion involved closure of a 10-cm incision on a simulated abdominal wall. Participants were timed, filmed, and graded using a standardized grading system. Thirty surgical and OB/GYN residents participated. All residents reported closing the abdominal wall continuously, 97% preferred slowly absorbing sutures (28/29), 97% preferred taking 1-cm bites (29/30), and 93% spaced bites 1 cm apart (27/29). However, 77% (10/13) of surgery residents identified 4:1 as the ideal suture to wound length ratio; 47% (7/15) of OB/GYN residents believed it to be 2:1, and another 40% (6/15) indicated 3:1 (p < 0.0001). In the simulation, OB/GYN residents used significantly fewer stitches (p = 0.0028), significantly more distance between bites (p < 0.0001), and significantly larger bite size (p < 0.0001) than surgery residents. When graded, there was no significant difference between programs. Despite some knowledge regarding the principles of abdominal wall closure among surgical and OB/GYN residents, more instruction is needed. We identified some differences in knowledge base and techniques for abdominal wall closure among general surgery and OB/GYN residents, which are likely due to differences in educational curriculums.

  13. Closure versus non-closure of the peritoneum at caesarean section: short- and long-term outcomes

    PubMed Central

    Bamigboye, Anthony A; Hofmeyr, G Justus

    2014-01-01

    Background Caesarean section is a very common surgical procedure worldwide. Suturing the peritoneal layers at caesarean section may or may not confer benefit, hence the need to evaluate whether this step should be omitted or routinely performed. Objectives The objective of this review was to assess the effects of non-closure as an alternative to closure of the peritoneum at caesarean section on intraoperative and immediate- and long-term postoperative outcomes. Search methods We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register (1 November 2013). Selection criteria Randomised controlled trials comparing leaving the visceral or parietal peritoneum, or both, unsutured at caesarean section with a technique which involves suturing the peritoneum in women undergoing elective or emergency caesarean section. Data collection and analysis Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked it for accuracy. Main results A total of 29 trials were included in this review and 21 trials (17,276 women) provided data that could be included in an analysis. The quality of the trials was variable. 1. Non-closure of visceral and parietal peritoneum versus closure of both parietal layers Sixteen trials involving 15,480 women, were included and analysed, when both parietal peritoneum was left unclosed versus when both peritoneal surfaces were closed. Postoperative adhesion formation was assessed in only four trials with 282 women, and no difference was found between groups (risk ratio (RR) 0.99, 95% confidence interval (CI) 0.76 to 1.29). There was significant reduction in the operative time (mean difference (MD) -5.81 minutes, 95% CI -7.68 to -3.93). The duration of hospital stay in a total of 13 trials involving 14,906 women, was also reduced (MD -0.26, 95% CI -0.47 to -0.05) days. In a trial involving 112 women, reduced chronic pelvic pain was found in the peritoneal non-closure group. 2. Non-closure of visceral peritoneum only versus closure of both peritoneal surfaces Three trials involving 889 women were analysed. There was an increase in adhesion formation (two trials involving 157 women, RR 2.49, 95% CI 1.49 to 4.16) which was limited to one trial with high risk of bias.There was reduction in operative time, postoperative days in hospital and wound infection. There was no significant reduction in postoperative pyrexia. 3. Non-closure of parietal peritoneum only versus closure of both peritoneal layers The two identified trials involved 573 women. Neither study reported on postoperative adhesion formation. There was reduction in operative time and postoperative pain with no difference in the incidence of postoperative pyrexia, endometritis, postoperative duration of hospital stay and wound infection. In only one study, postoperative day one wound pain assessed by the numerical rating scale, (MD -1.60, 95% CI -1.97 to -1.23) and chronic abdominal pain d by the visual analogue score (MD -1.10, 95% CI -1.39 to -0.81) was reduced in the non-closure group. 4. Non-closure versus closure of visceral peritoneum when parietal peritoneum is closed There was reduction in all the major urinary symptoms of frequency, urgency and stress incontinence when the visceral peritoneum is left unsutured. Authors’ conclusions There was a reduction in operative time across all the subgroups. There was also a reduction in the period of hospitalisation postcaesarean section except in the subgroup where parietal peritoneum only was not sutured where there was no difference in the period of hospitalisation. The evidence on adhesion formation was limited and inconsistent. There is currently insufficient evidence of benefit to justify the additional time and use of suture material necessary for peritoneal closure. More robust evidence on long-term pain, adhesion formation and infertility is needed. Plain Language Summary Closure versus non-closure of the peritoneum at caesarean section: long- and short-term outcome Not stitching the peritoneum after caesarean section takes less theatre time and therefore has less cost, but information on possible long-term disadvantages are limited. There are many ways of performing a caesarean section and the techniques used depend on a number factors including the clinical situation and the preference of the operator. The peritoneum is a thin membrane of cells supported by a thin layer of connective tissue, and during caesarean section these peritoneal surfaces have to be cut through in order to reach the uterus and for the baby to be born. Following a caesarean section, it has been standard practice to close the peritoneum by stitching (suturing) the two layers of tissue that line the abdomen and cover the internal organs, to restore the anatomy. It has however been suggested that peritoneal adhesions may be more likely rather than less likely when the peritoneum is sutured, possibly as a result of a tissue reaction to the suture material. This review of trials sought to address whether to routinely suture these thin layers of tissue or not after delivering a baby by caesarean section. Twenty-nine randomised controlled trials were identified, with differences in their methodological quality; 21 trials involving over 17,000 women contributing data to the review. Several minutes were saved when the peritoneum was not stitched, and with a shorter period of hospital stay in most of the women. Postoperative adhesion formation was assessed in only four trials with 282 women, and no difference was found when leaving both layers of peritoneumunclosed was compared with closure of both. Longer-term outcomes were not adequately assessed, particularly adhesion formation, subfertility and ease of other surgeries in later life. Although the methodological quality of trials was variable, the results were in general consistent between the trials of better and poorer quality. Further studies are needed to further assess all these outcomes. PMID:25110856

  14. Large eddy simulations of compressible magnetohydrodynamic turbulence

    NASA Astrophysics Data System (ADS)

    Grete, Philipp

    2017-02-01

    Supersonic, magnetohydrodynamic (MHD) turbulence is thought to play an important role in many processes - especially in astrophysics, where detailed three-dimensional observations are scarce. Simulations can partially fill this gap and help to understand these processes. However, direct simulations with realistic parameters are often not feasible. Consequently, large eddy simulations (LES) have emerged as a viable alternative. In LES the overall complexity is reduced by simulating only large and intermediate scales directly. The smallest scales, usually referred to as subgrid-scales (SGS), are introduced to the simulation by means of an SGS model. Thus, the overall quality of an LES with respect to properly accounting for small-scale physics crucially depends on the quality of the SGS model. While there has been a lot of successful research on SGS models in the hydrodynamic regime for decades, SGS modeling in MHD is a rather recent topic, in particular, in the compressible regime. In this thesis, we derive and validate a new nonlinear MHD SGS model that explicitly takes compressibility effects into account. A filter is used to separate the large and intermediate scales, and it is thought to mimic finite resolution effects. In the derivation, we use a deconvolution approach on the filter kernel. With this approach, we are able to derive nonlinear closures for all SGS terms in MHD: the turbulent Reynolds and Maxwell stresses, and the turbulent electromotive force (EMF). We validate the new closures both a priori and a posteriori. In the a priori tests, we use high-resolution reference data of stationary, homogeneous, isotropic MHD turbulence to compare exact SGS quantities against predictions by the closures. The comparison includes, for example, correlations of turbulent fluxes, the average dissipative behavior, and alignment of SGS vectors such as the EMF. In order to quantify the performance of the new nonlinear closure, this comparison is conducted from the subsonic (sonic Mach number M s ≈ 0.2) to the highly supersonic (M s ≈ 20) regime, and against other SGS closures. The latter include established closures of eddy-viscosity and scale-similarity type. In all tests and over the entire parameter space, we find that the proposed closures are (significantly) closer to the reference data than the other closures. In the a posteriori tests, we perform large eddy simulations of decaying, supersonic MHD turbulence with initial M s ≈ 3. We implemented closures of all types, i.e. of eddy-viscosity, scale-similarity and nonlinear type, as an SGS model and evaluated their performance in comparison to simulations without a model (and at higher resolution). We find that the models need to be calculated on a scale larger than the grid scale, e.g. by an explicit filter, to have an influence on the dynamics at all. Furthermore, we show that only the proposed nonlinear closure improves higher-order statistics.

  15. Effects of chronic iTBS-rTMS and enriched environment on visual cortex early critical period and visual pattern discrimination in dark-reared rats.

    PubMed

    Castillo-Padilla, Diana V; Funke, Klaus

    2016-01-01

    Early cortical critical period resembles a state of enhanced neuronal plasticity enabling the establishment of specific neuronal connections during first sensory experience. Visual performance with regard to pattern discrimination is impaired if the cortex is deprived from visual input during the critical period. We wondered how unspecific activation of the visual cortex before closure of the critical period using repetitive transcranial magnetic stimulation (rTMS) could affect the critical period and the visual performance of the experimental animals. Would it cause premature closure of the plastic state and thus worsen experience-dependent visual performance, or would it be able to preserve plasticity? Effects of intermittent theta-burst stimulation (iTBS) were compared with those of an enriched environment (EE) during dark-rearing (DR) from birth. Rats dark-reared in a standard cage showed poor improvement in a visual pattern discrimination task, while rats housed in EE or treated with iTBS showed a performance indistinguishable from rats reared in normal light/dark cycle. The behavioral effects were accompanied by correlated changes in the expression of brain-derived neurotrophic factor (BDNF) and atypical PKC (PKCζ/PKMζ), two factors controlling stabilization of synaptic potentiation. It appears that not only nonvisual sensory activity and exercise but also cortical activation induced by rTMS has the potential to alleviate the effects of DR on cortical development, most likely due to stimulation of BDNF synthesis and release. As we showed previously, iTBS reduced the expression of parvalbumin in inhibitory cortical interneurons, indicating that modulation of the activity of fast-spiking interneurons contributes to the observed effects of iTBS. © 2015 Wiley Periodicals, Inc.

  16. Understanding the basis of space closure in Orthodontics for a more efficient orthodontic treatment

    PubMed Central

    Ribeiro, Gerson Luiz Ulema; Jacob, Helder B.

    2016-01-01

    ABSTRACT Introduction: Space closure is one of the most challenging processes in Orthodontics and requires a solid comprehension of biomechanics in order to avoid undesirable side effects. Understanding the biomechanical basis of space closure better enables clinicians to determine anchorage and treatment options. In spite of the variety of appliance designs, space closure can be performed by means of friction or frictionless mechanics, and each technique has its advantages and disadvantages. Friction mechanics or sliding mechanics is attractive because of its simplicity; the space site is closed by means of elastics or coil springs to provide force, and the brackets slide on the orthodontic archwire. On the other hand, frictionless mechanics uses loop bends to generate force to close the space site, allowing differential moments in the active and reactive units, leading to a less or more anchorage control, depending on the situation. Objective: This article will discuss various theoretical aspects and methods of space closure based on biomechanical concepts. PMID:27275623

  17. Understanding the basis of space closure in Orthodontics for a more efficient orthodontic treatment.

    PubMed

    Ribeiro, Gerson Luiz Ulema; Jacob, Helder B

    2016-01-01

    Space closure is one of the most challenging processes in Orthodontics and requires a solid comprehension of biomechanics in order to avoid undesirable side effects. Understanding the biomechanical basis of space closure better enables clinicians to determine anchorage and treatment options. In spite of the variety of appliance designs, space closure can be performed by means of friction or frictionless mechanics, and each technique has its advantages and disadvantages. Friction mechanics or sliding mechanics is attractive because of its simplicity; the space site is closed by means of elastics or coil springs to provide force, and the brackets slide on the orthodontic archwire. On the other hand, frictionless mechanics uses loop bends to generate force to close the space site, allowing differential moments in the active and reactive units, leading to a less or more anchorage control, depending on the situation. This article will discuss various theoretical aspects and methods of space closure based on biomechanical concepts.

  18. [Closure of wide patent ductus arteriosus using a fenestrated muscular VSD occluder device in a pediatric patient with Down syndrome and pulmonary hypertension].

    PubMed

    Güvenç, Osman; Saygı, Murat; Demir, İbrahim Halil; Ödemiş, Ender

    2017-06-01

    Patients with wide patent ductus arteriosus and significant pulmonary hypertension not treated in time constitute a significant problem for cardiologists. For these patients, tests that could aid in decision-making for further planning include reversibility and balloon occlusion tests performed in the catheterization laboratory. Devices developed for the closure of ductus as well as different devices with off-label use may be employed in patients scheduled for transcatheter occlusion. When result of reversibility test is borderline positive, the use of fenestrated device may be applicable for selected patients. Presently described is case of a 10-year-old patient with Down syndrome who had a wide ductus and systemic pulmonary hypertension. Transcatheter closure procedure was performed with off-label use of a fenestrated muscular ventricular septal defect occluder device.

  19. Long-range correlations improve understanding of the influence of network structure on contact dynamics.

    PubMed

    Peyrard, N; Dieckmann, U; Franc, A

    2008-05-01

    Models of infectious diseases are characterized by a phase transition between extinction and persistence. A challenge in contemporary epidemiology is to understand how the geometry of a host's interaction network influences disease dynamics close to the critical point of such a transition. Here we address this challenge with the help of moment closures. Traditional moment closures, however, do not provide satisfactory predictions close to such critical points. We therefore introduce a new method for incorporating longer-range correlations into existing closures. Our method is technically simple, remains computationally tractable and significantly improves the approximation's performance. Our extended closures thus provide an innovative tool for quantifying the influence of interaction networks on spatially or socially structured disease dynamics. In particular, we examine the effects of a network's clustering coefficient, as well as of new geometrical measures, such as a network's square clustering coefficients. We compare the relative performance of different closures from the literature, with or without our long-range extension. In this way, we demonstrate that the normalized version of the Bethe approximation-extended to incorporate long-range correlations according to our method-is an especially good candidate for studying influences of network structure. Our numerical results highlight the importance of the clustering coefficient and the square clustering coefficient for predicting disease dynamics at low and intermediate values of transmission rate, and demonstrate the significance of path redundancy for disease persistence.

  20. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    PubMed

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing has recently gained industry attention due to increased regulatory agency scrutiny regarding the analytical rigor of container closure integrity testing methods and expectations to use container closure integrity testing in lieu of sterility tests in stability programs. Methylene blue dye is often used for dye ingress testing of container closure integrity, but we found it unsuitable for reliable detection of small breaches in prefilled syringes of drug product. This work describes the suitability and advantages of using a fluorescent dye and spectroscopic detection for a robust, sensitive, and quality control-friendly container closure integrity testing method for prefilled syringes. © PDA, Inc. 2016.

  1. 75 FR 19422 - Notice of Closure of Airport Mesa/Carizzo Creek Shooting Area in Eastern San Diego County, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-14

    ...The Bureau of Land Management (BLM) has closed approximately 210 acres of public land described as the Airport Mesa/Carrizo Creek shooting area located in eastern San Diego County, California. The closure order prohibits recreational shooting and target practice. The use of firearms will continue to be allowed for hunting consistent with California Department of Fish and Game regulations and seasons. This closure order is necessary in order to protect U.S. Border Patrol agents as they perform their duties along the top of Airport Mesa.

  2. Perineal Hernia Is an Unusual Complication Post Perineal Bladder Neck Closure: A Case Report.

    PubMed

    Omar, Helmy; Helmy, Tamer E; Hafez, Ashraf T; Dawaba, Mohamed E

    2017-03-01

    Bladder neck closure (BNC) is the ultimate bladder neck reconstruction. If reconstruction fails, closure must be considered as it gives the highest continence rate. The vast majority of BNCs are performed through an abdominal approach (either transvesical or extravesical approach), but perineal approach remains an option for BNC with considerable success rate. Perineal hernia, which is defined as protrusion of abdominal contents through the perineal defect, is a very rare complication after urologic procedures. We report a case of perineal hernia post perineal BNC. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. A new technique for the closure of the lens capsule by laser welding.

    PubMed

    Pini, Roberto; Rossi, Francesca; Menabuoni, Luca; Lenzetti, Ivo; Yoo, Sonia; Parel, Jean-Marie

    2008-01-01

    A new method is presented for the closure of the lens capsule based on laser welding of suitably prepared patches of anterior capsular tissue. Experiments were performed in freshly enucleated porcine eyes. The patches were previously stained with a solution of indocyanine green in sterile water and then welded on the recipient capsule by means of diode laser radiation at 810 nm. The welded tissue revealed mechanical properties comparable to those of healthy tissue. This technique is proposed to repair capsular breaks and to provide the closure of the capsulorhexis in lens refilling procedures.

  4. Closing Schools to Improve Student Achievement: What the Research and Researchers Say. Research Summary

    ERIC Educational Resources Information Center

    American Federation of Teachers (NJ), 2012

    2012-01-01

    School districts close schools for many appropriate reasons. School closure has now evolved into a school improvement strategy. Sometimes the strategy is to close the lowest-performing schools rather than low-enrollment schools and move the students into higher-achieving neighborhood schools. School closure also has become a common strategy to…

  5. Swatch Testing at Elevated Wind Speeds

    DTIC Science & Technology

    2014-07-17

    closures, for improved system performance. 15. SUBJECT TERMS Swatch Testing; Individual Protective Equipment (IPE) 16. SECURITY CLASSIFICATION...new wind tunnel swatch technique allows the systematic testing IPE components, such as fasteners, seams, and closures, for improved system...protective overgarment) achieve this isolation by sealing users in a chemically impermeable garment . Heat stress becomes a major problem with this

  6. Eye-closure-triggered paroxysmal activity and cognitive impairment: a case report.

    PubMed

    Termine, Cristiano; Rubboli, Guido; Veggiotti, Pierangelo

    2006-01-01

    To study the neuropsychological status of an epileptic patient presenting with epileptic activity triggered by eye closure in a 14-year follow-up period. The patient was studied at 12 and 26 years of age; during this period he underwent periodical clinical evaluations and EEG investigations; brain magnetic resonance imaging (MRI) was performed at 12 years of age. A neuropsychological assessment was carried out both at 12 years of age (T0) and at 26 years of age. At T0 and T1, neuropsychological tests (digits and words span, graphoestesia, reactions time to auditory stimuli, sentences repetition, words repetition, digital gnosis, backward counting [i.e.,100-0]) were performed during video-EEG monitoring either with eyes closed or with eyes open, to evaluate possible transitory effects related to ongoing epileptic activity. Moreover, at T0 the patient underwent Wechsler Intelligence Scale for Children-Revised, and at T1 to Wechsler Adult Intelligence Scale-Revised. EEG recordings showed continuous epileptic activity triggered by eye closure, disappearing only with eyes opening, both at T0 and T1 (in this latter case, anteriorly predominant). The results of neuropsychological assessment during eyes closed as compared to performances with eyes open did not show significant differences, at T0 as well as at T1. Wechsler Intelligence scales showed a deterioration of performances at T1 with respect to T0; in addition, at T1, attention and short-term memory abnormalities, impairment in facial recognition and block design, and defective results in Continuous Performance Test and Wisconsin Card Sorting Test were observed. Lack of differences between the results of neuropsychological tests performed with eyes closed as compared to the eyes open condition suggests that in our patient epileptic activity did not cause transitory cognitive abnormalities. Deterioration of Wechsler Intelligence Scales in the follow-up period might be interpreted as the result of a disruption of cognitive processes possibly related to the persistence of a continuous epileptic activity during eye closure over the years. We speculate whether a dysfunction in posterior cortical areas involved in visual processing might be related to the impairment in face recognition and block design tests as well to eye closure sensitivity.

  7. Anatomy of emotion: a 3D study of facial mimicry.

    PubMed

    Ferrario, V F; Sforza, C

    2007-01-01

    Alterations in facial motion severely impair the quality of life and social interaction of patients, and an objective grading of facial function is necessary. A method for the non-invasive detection of 3D facial movements was developed. Sequences of six standardized facial movements (maximum smile; free smile; surprise with closed mouth; surprise with open mouth; right side eye closure; left side eye closure) were recorded in 20 healthy young adults (10 men, 10 women) using an optoelectronic motion analyzer. For each subject, 21 cutaneous landmarks were identified by 2-mm reflective markers, and their 3D movements during each facial animation were computed. Three repetitions of each expression were recorded (within-session error), and four separate sessions were used (between-session error). To assess the within-session error, the technical error of the measurement (random error, TEM) was computed separately for each sex, movement and landmark. To assess the between-session repeatability, the standard deviation among the mean displacements of each landmark (four independent sessions) was computed for each movement. TEM for the single landmarks ranged between 0.3 and 9.42 mm (intrasession error). The sex- and movement-related differences were statistically significant (two-way analysis of variance, p=0.003 for sex comparison, p=0.009 for the six movements, p<0.001 for the sex x movement interaction). Among four different (independent) sessions, the left eye closure had the worst repeatability, the right eye closure had the best one; the differences among various movements were statistically significant (one-way analysis of variance, p=0.041). In conclusion, the current protocol demonstrated a sufficient repeatability for a future clinical application. Great care should be taken to assure a consistent marker positioning in all the subjects.

  8. Fracture Gap Reduction With Variable-Pitch Headless Screws.

    PubMed

    Roebke, Austin J; Roebke, Logan J; Goyal, Kanu S

    2018-04-01

    Fully threaded, variable-pitch, headless screws are used in many settings in surgery and have been extensively studied in this context, especially in regard to scaphoid fractures. However, it is not well understood how screw parameters such as diameter, length, and pitch variation, as well as technique parameters such as depth of drilling, affect gap closure. Acutrak 2 fully threaded variable-pitch headless screws of various diameters (Standard, Mini, and Micro) and lengths (16-28 mm) were inserted into polyurethane blocks of "normal" and "osteoporotic" bone model densities using a custom jig. Three drilling techniques (drill only through first block, 4 mm into second block, or completely through both blocks) were used. During screw insertion, fluoroscopic images were taken and later analyzed to measure gap reduction. The effect of backing the screw out after compression was evaluated. Drilling at least 4 mm past the fracture site reduces distal fragment push-off compared with drilling only through the proximal fragment. There were no significant differences in gap closure in the normal versus the osteoporotic model. The Micro screw had a smaller gap closure than both the Standard and the Mini screws. After block contact and compression with 2 subsequent full forward turns, backing the screw out by only 1 full turn resulted in gapping between the blocks. Intuitively, fully threaded headless variable-pitch screws can obtain compression between bone fragments only if the initial gap is less than the gap closed. Gap closure may be affected by drilling technique, screw size, and screw length. Fragment compression may be immediately lost if the screw is reversed. We describe characteristics of variable-pitch headless screws that may assist the surgeon in screw choice and method of use. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Patent ductus arteriosus in infants <29 weeks gestation--outcomes and factors affecting closure.

    PubMed

    Popat, H; Kapoor, V; Travadi, J

    2012-08-01

    To determine Patent ductus arteriosus (PDA) closure rates for extremely preterm infants in a tertiary care centre, factors affecting response to indomethacin and outcomes of these infants relative to their PDA status. Neonatal intensive care unit in tertiary-care children's hospital. Retrospective medical record review. A retrospective chart review of all infants <29 weeks gestation between 1st Jan 2003 and 30th June 2006 was carried out. Multiple courses of standard intravenous indomethacin (dose: 0.2 mg/kg 12 hourly; 3 doses) followed by a tail course (0.1 mg/kg/day; 3 doses) were used to treat PDA depending on clinical and hemodynamic status. Data on demographic characteristics, PDA status, use of indomethacin, and outcome factors such as chronic lung disease and mortality were collected. A total of 166 infants were identified in the study period, of which 15 were excluded. The median gestation was 27 weeks [IQR (25, 28)] and the mean (SD) birthweight was 950 (244) grams. The remaining infants (n=151) were divided into three groups. Group1 (n=47): no or non-significant PDA, Group 2 (n=91): significant PDA closed after indomethacin treatment (= 1 course) and Group 3 (n=13): significant PDA not responding to indomethacin. The closure rate of PDA with indomethacin treatment (group 2) was 87%. A low gestational age < 26 weeks (OR 5.6, 95% CI 1.6-19.9) and female sex (OR 5.8, 95% CI 1.5-22.8) was associated with poor response to indomethacin in our study population. Multiple indomethacin courses using the standard dosing approach result in high PDA closure rates for infants < 29 weeks gestation.

  10. Positioning In Macular hole Surgery (PIMS): statistical analysis plan for a randomised controlled trial.

    PubMed

    Bell, Lauren; Hooper, Richard; Bunce, Catey; Pasu, Saruban; Bainbridge, James

    2017-06-13

    The treatment of idiopathic full-thickness macular holes involves surgery to close the hole. Some surgeons advise patients to adopt a face-down position to increase the likelihood of successful macular hole closure. However, patients often find the face-down positioning arduous. There is a lack of conclusive evidence that face-down positioning improves the outcome. The 'Positioning In Macular hole Surgery' (PIMS) trial will assess whether advice to position face-down after surgery improves the surgical success rate for the closure of large (≥400 μm) macular holes. The PIMS trial is a multicentre, parallel-group, superiority clinical trial with 1:1 randomisation. Patients (n = 192) with macular holes (≥400 μm) will be randomised after surgery to either face-down positioning or face-forward positioning for at least 8 h (which can be either consecutive or nonconsecutive) a day, for 5 days following surgery. Inclusion criteria are: presence of an idiopathic full-thickness macular hole ≥400 μm in diameter, as measured by optical coherence tomography (OCT) scans, on either or both eyes; patients electing to have surgery for a macular hole, with or without simultaneous phacoemulsification and intraocular lens implant; ability and willingness to position face-down or in an inactive face-forward position; a history of visual loss suggesting a macular hole of 12 months' or less duration. The primary outcome is successful macular hole closure at 3 months post surgery. The treatment effect will be reported as an odds ratio with 95% confidence interval, adjusted for size of macular hole and phakic lens status at baseline. Secondary outcome measures at 3 months are: further surgery for macular holes performed or planned (of those with unsuccessful closure); patient-reported experience of positioning; whether patients report they would still have elected to have the operation given what they know at follow-up; best-corrected visual acuity (BCVA) measured using Snellen charts at a standard distance of 6 m; patient-reported health and quality of life assessed using the National Eye Institute Visual Function Questionnaire (VFQ-25). The PIMS trial is the first multicentre randomised control trial to investigate the value of face-down positioning following macular hole standardised surgery. International Standard Randomised Controlled Trials Number registry, ID: ISRCTN12410596. Registered on 11 February 2015. United Kingdom Clinical Research Network, ID: UKCRN17966 . Registered on 26 November 2014.

  11. 40 CFR 264.603 - Post-closure care.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES... treatment or storage unit has contaminated soils or ground water that cannot be completely removed or...

  12. SPONTANEOUS CLOSURE OF A MACULAR HOLE AFTER FOUR FAILED VITRECTOMIES IN THE SETTING OF NF-1.

    PubMed

    Wannamaker, Kendall W; Sharpe, Robert A; Kylstra, Jan A

    2018-01-01

    To present the case of a patient who developed spontaneous closure of an idiopathic macular hole after four failed attempts at surgical closure. This is a retrospective case review of the medical record of a single patient. No statistical analysis was performed. The patient is a 71-year-old white woman with neurofibromatosis Type 1 who presented to the retina clinic of one of the authors. The patient underwent four vitrectomies with long acting gas by two surgeons over the course of 2 years. After each surgery, the hole either did not close or it closed and then reopened within 1 year. Five months after the last surgery (1 year after the hole last reopened), the patient presented with improved vision and spontaneous closure of the macular hole. The hole has remained closed since then. This case demonstrates that spontaneous closure of a macular hole, associated with excellent visual recovery, can occur after multiple surgical failures. We propose that enhanced scar formation due to neurofibromatosis Type 1 was responsible for both the numerous failures following initially successful surgery (centrifugal traction) and for the spontaneous closure (centripetal traction).

  13. Taking Closure to the Next Level - 13030

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feist, E.T.

    2013-07-01

    The River Corridor Closure Project (RCCP) is the Hanford Site's first closure project and when it is complete, in 2015, it will have cleaned up 220 mi{sup 2} of contaminated land adjacent to the Columbia River. Washington Closure Hanford (WCH) was selected by the DOE to manage the removal and cleanup of Hanford's nuclear legacy along the River Corridor. Work began in 2005 and is now more than 85% complete with more than 2 years left in the contract. A Closure Team was commissioned in December 2009 and has since issued a closure strategy and a disciplined three-phase approach tomore » transition land parcels to DOE, Richland Operations Office (DOE-RL) as cleanup is completed. This process supports DOE-RL objectives for progressive footprint reduction based on the division of the River Corridor into geographical land parcels. It also allows for incremental area-by-area transition and turnover to the Long-Term Stewardship program. Several important milestones stand between now and the successful end of the RCCP. They include overall funding impacts, working with DOE-RL on new scope additions, meeting regulatory milestones, and maintaining a strong safety performance. (authors)« less

  14. Association of Antegrade Pulmonary Artery Diastolic Velocity with Spontaneous Closure of the Patent Ductus Arteriosus in Extremely Low-Birth-Weight Infants.

    PubMed

    Weiss, Dawn M; Kaiser, Jeffrey R; Swearingen, Christopher; Malik, Sadia; Sachdeva, Ritu

    2015-11-01

    This study aims to determine echocardiographic parameters associated with spontaneous patent ductus arteriosus (PDA) closure in extremely low-birth-weight (ELBW) infants. Retrospective demographic review and analysis of echocardiograms from 189 ELBW infants with suspected and confirmed hemodynamically significant PDA identified on an initial echocardiogram was performed. Comparison of echocardiographic parameters was made between infants with spontaneous closure versus those who received treatment. The mean birth weight (787 ± 142 vs. 724 ± 141 g, p = 0.04) and gestational age (27.4 ± 2.8 vs. 26.2 ± 1.6 weeks, p = 0.03) were higher in the spontaneous closure versus the treatment group. Antegrade pulmonary artery (PA) diastolic velocity was lower in infants with spontaneous PDA closure versus those who received treatment (0.15 ± 0.06 vs. 0.22 ± 0.12 m/s, p = 0.009). Heavier and more mature ELBW infants with a lower antegrade PA diastolic velocity were likely to have spontaneous closure of the PDA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, J.; Glucksberg, N.; Fogg, A.

    During the site closure of nuclear facilities where both radionuclides and chemicals are present in environmental media, state and federal regulatory agencies other than the Nuclear Regulatory Commission often have a stake in the regulation of the site closure process. At the Connecticut Yankee Atomic Power Company (CYAPCO) Haddam Neck Plant in Haddam, Connecticut, the site closure process includes both radiological and chemical cleanup which is regulated by two separate divisions within the state and two federal agencies. Each of the regulatory agencies has unique closure criteria which pertain to radionuclides and, consequently, there is overlapping and in some casesmore » disparate regulation of radionuclides. Considerable effort has been expended by CYAPCO to find common ground in meeting the site closure requirements for radionuclides required by each of the agencies. This paper discusses the approaches that have been used by CYAPCO to address radionuclide site closure requirements. Significant lessons learned from these approaches include the demonstration that public health cleanup criteria for most radionuclides of concern at nuclear power generation facilities are protective for chemical toxicity concerns and are protective for ecological receptors and, consequently, performing a baseline ecological risk assessment for radionuclides at power generation facilities is not generally necessary. (authors)« less

  16. Complete closure of artificial gastric ulcer after endoscopic submucosal dissection by combined use of a single over-the-scope clip and through-the-scope clips (with videos).

    PubMed

    Maekawa, Satoshi; Nomura, Ryosuke; Murase, Takayuki; Ann, Yasuyoshi; Harada, Masaru

    2015-02-01

    A 5-7 day hospital stay is usually needed after endoscopic submucosal dissection (ESD) of gastric tumor because of the possibility of delayed perforation or bleeding. The aim of this study was to evaluate the efficacy of combined use of a single over-the-scope clip (OTSC) and through-the-scope clips (TTSCs) to achieve complete closure of artificial gastric ulcer after ESD. We prospectively studied 12 patients with early gastric cancer or gastric adenoma. We performed complete closure of post-ESD artificial gastric ulcer using a combination of a single OTSC and TTSCs. Mean size of post-ESD artificial ulcer was 54.6 mm. The mean operating time for the closure procedure was 15.2 min., and the success rate was 91.7 % (11/12). Patients who underwent complete closure of post-ESD artificial gastric ulcer could be discharged the day after ESD and the closing procedure. Complete closure of post-ESD artificial gastric ulcer using a combination of a single OTSC and TTSCs is useful for shortening the period of hospitalization and reducing treatment cost.

  17. Observations and Models of Highly Intermittent Phytoplankton Distributions

    PubMed Central

    Mandal, Sandip; Locke, Christopher; Tanaka, Mamoru; Yamazaki, Hidekatsu

    2014-01-01

    The measurement of phytoplankton distributions in ocean ecosystems provides the basis for elucidating the influences of physical processes on plankton dynamics. Technological advances allow for measurement of phytoplankton data to greater resolution, displaying high spatial variability. In conventional mathematical models, the mean value of the measured variable is approximated to compare with the model output, which may misinterpret the reality of planktonic ecosystems, especially at the microscale level. To consider intermittency of variables, in this work, a new modelling approach to the planktonic ecosystem is applied, called the closure approach. Using this approach for a simple nutrient-phytoplankton model, we have shown how consideration of the fluctuating parts of model variables can affect system dynamics. Also, we have found a critical value of variance of overall fluctuating terms below which the conventional non-closure model and the mean value from the closure model exhibit the same result. This analysis gives an idea about the importance of the fluctuating parts of model variables and about when to use the closure approach. Comparisons of plot of mean versus standard deviation of phytoplankton at different depths, obtained using this new approach with real observations, give this approach good conformity. PMID:24787740

  18. Multi-Material Closure Model for High-Order Finite Element Lagrangian Hydrodynamics

    DOE PAGES

    Dobrev, V. A.; Kolev, T. V.; Rieben, R. N.; ...

    2016-04-27

    We present a new closure model for single fluid, multi-material Lagrangian hydrodynamics and its application to high-order finite element discretizations of these equations [1]. The model is general with respect to the number of materials, dimension and space and time discretizations. Knowledge about exact material interfaces is not required. Material indicator functions are evolved by a closure computation at each quadrature point of mixed cells, which can be viewed as a high-order variational generalization of the method of Tipton [2]. This computation is defined by the notion of partial non-instantaneous pressure equilibration, while the full pressure equilibration is achieved bymore » both the closure model and the hydrodynamic motion. Exchange of internal energy between materials is derived through entropy considerations, that is, every material produces positive entropy, and the total entropy production is maximized in compression and minimized in expansion. Results are presented for standard one-dimensional two-material problems, followed by two-dimensional and three-dimensional multi-material high-velocity impact arbitrary Lagrangian–Eulerian calculations. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.« less

  19. Evaluation of age determination techniques for gray wolves

    USGS Publications Warehouse

    Landon, D.B.; Waite, C.A.; Peterson, R.O.; Mech, L.D.

    1998-01-01

    We evaluated tooth wear, cranial suture fusion, closure of the canine pulp cavity, and cementum annuli as methods of age determination for known- and unknown-age gray wolves (Canis lupus) from Alaska, Minnesota, Ontario, and Isle Royale, Michigan. We developed age classes for cranial suture closure and tooth wear. We used measurement data obtained from known-age captive and wild wolves to generate a regression equation to predict age based on the degree of closure of the canine pulp cavity. Cementum annuli were studied in known- and unknown-age animals, and calcified, unstained thin sections were found to provide clear annulus patterns under polarized transmitted light. Annuli counts varied among observers, partly because of variation in the pattern of annuli in different regions of the cementum. This variation emphasizes the need for standardized models of cementum analysis. Cranial suture fusion is of limited utility in age determination, while tooth wear can be used to estimate age of adult wolves within 4 years. Wolves lt 7 years old could be aged to within 13 years with the regression equation for closure of the canine pulp cavity. Although inaccuracy remains a problem, cementum-annulus counts were the most promising means of estimating age for gray wolves.

  20. Multi-Material Closure Model for High-Order Finite Element Lagrangian Hydrodynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dobrev, V. A.; Kolev, T. V.; Rieben, R. N.

    We present a new closure model for single fluid, multi-material Lagrangian hydrodynamics and its application to high-order finite element discretizations of these equations [1]. The model is general with respect to the number of materials, dimension and space and time discretizations. Knowledge about exact material interfaces is not required. Material indicator functions are evolved by a closure computation at each quadrature point of mixed cells, which can be viewed as a high-order variational generalization of the method of Tipton [2]. This computation is defined by the notion of partial non-instantaneous pressure equilibration, while the full pressure equilibration is achieved bymore » both the closure model and the hydrodynamic motion. Exchange of internal energy between materials is derived through entropy considerations, that is, every material produces positive entropy, and the total entropy production is maximized in compression and minimized in expansion. Results are presented for standard one-dimensional two-material problems, followed by two-dimensional and three-dimensional multi-material high-velocity impact arbitrary Lagrangian–Eulerian calculations. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.« less

  1. Photographic Standards for Patients With Facial Palsy and Recommendations by Members of the Sir Charles Bell Society.

    PubMed

    Santosa, Katherine B; Fattah, Adel; Gavilán, Javier; Hadlock, Tessa A; Snyder-Warwick, Alison K

    2017-07-01

    There is no widely accepted assessment tool or common language used by clinicians caring for patients with facial palsy, making exchange of information challenging. Standardized photography may represent such a language and is imperative for precise exchange of information and comparison of outcomes in this special patient population. To review the literature to evaluate the use of facial photography in the management of patients with facial palsy and to examine the use of photography in documenting facial nerve function among members of the Sir Charles Bell Society-a group of medical professionals dedicated to care of patients with facial palsy. A literature search was performed to review photographic standards in patients with facial palsy. In addition, a cross-sectional survey of members of the Sir Charles Bell Society was conducted to examine use of medical photography in documenting facial nerve function. The literature search and analysis was performed in August and September 2015, and the survey was conducted in August and September 2013. The literature review searched EMBASE, CINAHL, and MEDLINE databases from inception of each database through September 2015. Additional studies were identified by scanning references from relevant studies. Only English-language articles were eligible for inclusion. Articles that discussed patients with facial palsy and outlined photographic guidelines for this patient population were included in the study. The survey was disseminated to the Sir Charles Bell Society members in electronic form. It consisted of 10 questions related to facial grading scales, patient-reported outcome measures, other psychological assessment tools, and photographic and videographic recordings. In total, 393 articles were identified in the literature search, 7 of which fit the inclusion criteria. Six of the 7 articles discussed or proposed views specific to patients with facial palsy. However, none of the articles specifically focused on photographic standards for the population with facial palsy. Eighty-three of 151 members (55%) of the Sir Charles Bell Society responded to the survey. All survey respondents used photographic documentation, but there was variability in which facial expressions were used. Eighty-two percent (68 of 83) used some form of videography. From these data, we propose a set of minimum photographic standards for patients with facial palsy, including the following 10 static views: at rest or repose, small closed-mouth smile, large smile showing teeth, elevation of eyebrows, closure of eyes gently, closure of eyes tightly, puckering of lips, showing bottom teeth, snarling or wrinkling of the nose, and nasal base view. There is no consensus on photographic standardization to report outcomes for patients with facial palsy. Minimum photographic standards for facial paralysis publications are proposed. Videography of the dynamic movements of these views should also be recorded. NA.

  2. Potential supplementary utility of combined PFA-100 and functional von Willebrand factor testing for the laboratory assessment of desmopressin and factor concentrate therapy in von Willebrand disease.

    PubMed

    Favaloro, Emmanuel J; Thom, Jim; Patterson, David; Just, Sarah; Baccala, Maria; Dixon, Tracy; Meiring, Muriel; Koutts, Jerry; Rowell, John; Baker, Ross

    2009-09-01

    We performed a retrospective audit of cross-laboratory testing of desmopressin and factor concentrate therapy to assess the potential utility of supplementary testing using the PFA-100 with functional von Willebrand factor (VWF) activity testing. Data were evaluated for a large number of patients with von Willebrand disease of type 1, type 2A or type 2M, as well as a comparative subset of individuals with haemophilia or carriers of haemophilia. Laboratory testing comprised pre and postdesmopressin, or pre and postconcentrate, evaluation of factor VIII, VWF antigen (VWF:Ag) and VWF ristocetin cofactor activity as traditionally performed, supplemented with collagen-binding (VWF:CB) testing and PFA-100 closure times. In brief, both therapies tended to normalize VWF test parameters and closure times in individuals with type 1 von Willebrand disease, with the level of correction in closure times related to the level of normalization of VWF, particularly the VWF:CB. However, although occasional correction of closure times was observed in patients with type 2A or type 2M von Willebrand disease, these did not in general normalize PFA-100 closure times either with desmopressin or factor concentrate therapy. In these patients, improvement in closure times was more likely in those in whom VWF:CB values normalized or when VWF:CB/VWF:Ag ratios normalized. This study confirms that there is a strong relationship between the presenting levels of plasma VWF and PFA-100 closure times, and that the supplementary combination of PFA-100 and VWF:CB testing might provide added clinical utility to current broadly applied testing strategies limited primarily to VWF:Ag, VWF ristocetin cofactor and factor VIII:coagulant. Future prospective investigations are warranted to validate these relationships and to investigate their therapeutic implications.

  3. Concomitant surgical closure of left atrial appendage: A systematic review and meta-analysis.

    PubMed

    Ando, Masahiko; Funamoto, Masaki; Cameron, Duke E; Sundt, Thoralf M

    2018-03-12

    Although percutaneous closure of the left atrial appendage is supported as a potential alternative to lifelong anticoagulation in patients with atrial fibrillation, comprehensive evidence on surgical left atrial appendage closure in heart surgery is limited. We conducted a meta-analysis of studies comparing patients who underwent open cardiac surgery with or without left atrial appendage closure. A literature search was performed on PubMed, Embase, and Cochrane Trials databases. Outcomes of interest were 30-day/in-hospital mortality and cerebrovascular accident. I 2 statistics were used to evaluate heterogeneity, and publication bias was evaluated by Begg's and Egger's tests. We reviewed 1284 articles and selected for main analysis 7 articles including 3897 patients (1963 in the left atrial appendage closure group and 1934 in the non-left atrial appendage closure group). Among the 7 studies, 3 were randomized-controlled studies, 3 were propensity-matched studies, and 1 was a case-matching study. At 30-day/in-hospital follow-up, left atrial appendage closure was significantly associated with decreased risk of mortality and cerebrovascular accident (odds ratio, 0.384, 95% confidence interval, 0.233-0.631 for mortality, and odds ratio, 0.622, 95% confidence interval, 0.388-0.998 for cerebrovascular accident). Stratified analysis demonstrated that this association was more prominent in preoperative atrial fibrillation strata. Concomitant surgical left atrial appendage closure should be considered at the time of open cardiac surgery, particularly among those in atrial fibrillation preoperatively. The benefit of left atrial appendage closure for patients not in atrial fibrillation and for those undergoing nonvalvular surgery is still unclear. Further prospective investigations are indicated. Copyright © 2018. Published by Elsevier Inc.

  4. Short-term safety and efficacy of left atrial appendage closure with the WATCHMAN device in patients with small left atrial appendage ostia.

    PubMed

    Venkataraman, Ganesh; Strickberger, S Adam; Doshi, Shephal; Ellis, Christopher R; Lakkireddy, Dhanunjaya; Whalen, S Patrick; Cuoco, Frank

    2018-01-01

    Left atrial appendage (LAA) closure with the WATCHMAN device, according to FDA labelling, is recommended in patients with a maximal LAA ostial width between 17 and 31 mm. The safety and efficacy of LAA closure in patients with a maximal LAA ostial width < 17 mm has not been evaluated. The goal of this study was to determine the acute and short-term safety and efficacy of LAA closure with the WATCHMAN device in patients with a maximal LAA ostial width < 17 mm. Thirty-two consecutive patients with a maximal LAA ostial width < 17 mm as determined by a screening transesophageal echocardiogram (TEE) underwent LAA closure with the WATCHMAN device between March 2015 and November 2016 at five medical centers, and were included in this study. Mean age, body mass index (BMI), and CHA 2 DS 2 -VASC score were 70.8 ± 8.6 years, 29.3 ± 6.5 kg/m 2 , and 3.9 ±1.2, respectively. At the screening TEE, mean maximal LAA ostial width and depth were 15.6 ± 0.6 mm (range 14-16) and 23.2 ± 4.5 mm (range 13-31), respectively. Successful LAA closure with the WATCHMAN device was achieved in 31 of 32 patients (97%), with no major complications. TEE performed 45 days after LAA closure demonstrated no peridevice leak > 5 mm and no device related thrombi. Warfarin was discontinued in all 31 patients 45 days after LAA closure. LAA closure with the WATCHMAN device can be successfully and safely achieved in patients with a maximal LAA ostial width < 17 mm. © 2017 Wiley Periodicals, Inc.

  5. Transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of perimembranous ventricular septal defects in children: a protocol for a network meta-analysis.

    PubMed

    You, Tao; Yi, Kang; Ding, Zhao-Hong; Hou, Xiao-Dong; Liu, Xing-Guang; Wang, Xin-Kuan; Ge, Long; Tian, Jin-Hui

    2017-06-21

    Both transcatheter device closure and surgical repair are effective treatments with excellent midterm outcomes for perimembranous ventricular septal defects (pmVSDs) in children. The mini-invasive periventricular device occlusion technique has become prevalent in research and application, but evidence is limited for the assessment of transcatheter closure, mini-invasive closure and open-heart surgical repair. This study comprehensively compares the efficacy, safety and costs of transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of pmVSDs in children using Bayesian network meta-analysis. A systematic search will be performed using Chinese Biomedical Literature Database, China National Knowledge Infrastructure, PubMed, EMBASE.com and the Cochrane Central Register of Controlled Trials to include random controlled trials, prospective or retrospective cohort studies comparing the efficacy, safety and costs of transcatheter closure, mini-invasive closure and open-heart surgical repair. The risk of bias for the included prospective or retrospective cohort studies will be evaluated according to the risk of bias in non-randomised studies of interventions (ROBINS-I). For random controlled trials, we will use risk of bias tool from Cochrane Handbook version 5.1.0. A Bayesian network meta-analysis will be conducted using R-3.3.2 software. Ethical approval and patient consent are not required since this study is a network meta-analysis based on published trials. The results of this network meta-analysis will be submitted to a peer-reviewed journal for publication. CRD42016053352. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Left ventricular remodeling and change of systolic function after closure of patent ductus arteriosus in adults: device and surgical closure.

    PubMed

    Jeong, Young-Hoon; Yun, Tae-Jin; Song, Jong-Min; Park, Jung-Jun; Seo, Dong-Man; Koh, Jae-Kon; Lee, Se-Whan; Kim, Mi-Jeong; Kang, Duk-Hyun; Song, Jae-Kwan

    2007-09-01

    Left ventricular (LV) remodeling and predictors of LV systolic function late after closure of patent ductus arteriosus (PDA) in adults remain to be clearly demonstrated. In 45 patients with PDA, including 28 patients who received successful occlusion using the Amplatzer device (AD group) (AGA, Golden Valley, MN) and 17 patients who received surgical closure (OP group), echocardiography studies were performed before closure and 1 day (AD group) or within 7 days (OP group) after closure, and then were repeated at > or = 6 months (17 +/- 13 months). In both groups, LV ejection fraction (EF) and end-diastolic volume index were significantly decreased immediately after closure, whereas end-systolic volume index did not change. During the long-term follow-up period, end-systolic as well as end-diastolic volume indices decreased significantly in both groups and LV EF recovered compared to the immediate postclosure state. However, LV EF remained low compared to the preclosure state. Five patients (11.1%) including 3 patients in the AD group and 2 patients in the OP group showed persistent late LV systolic dysfunction (EF <50%). In stepwise, multiple logistic regression analysis, preclosure EF was the only independent predictor of late normal postclosure EF (odds ratio, 1.230; 95% CI, 1.054-1.434; P = .008). Receiver operating characteristic curve analysis showed that preclosure EF > or = 62% had a sensitivity of 72% and a specificity of 83% for predicting late normal LV EF after closure. Left ventricular EF remains low late after PDA closure compared with preclosure state in adults. Preclosure LV EF is the best index to predict late postclosure LV EF.

  7. Use of adhesive surgical tape with the absorbable continuous subcuticular suture.

    PubMed

    Kolt, Jeremy D

    2003-08-01

    The absorbable continuous subcuticular suture is frequently used to close surgical incisions where the aim is healing by primary intention. A form of adhesive surgical tape is commonly also placed over the wound but this combination closure seems to have its development based on anecdotal, rather than experimental evidence. The present study reviews the scientific literature on the development of sutureless wound closure and presents the current evidence for the use of combination wound closure. Review was undertaken of the medical literature using the PubMed Internet database and cross-referencing major -articles on the subject. The following combinations of key words were searched: skin closure, wound closure, suture technique, sutureless, adhesive tape, op-site, staples, subcuticular suture, complication, infection and scars. Taped closure alone has advantages of lower wound infection rates and greater wound tensile strength, but disadvantages of epidermal reaction, skin edge inversion, doubtful safety and time required for meticulous surgical technique. The use of the continuous absorbable subcuticular suture allows accurate skin edge approximation, which increases the safety margin. The combination closure has a slightly superior cosmetic result to sutureless techniques but no study has been performed to compare the results of combination subcuticular suture and tape, with tape or subcuticular suture alone. There is no evidence in the scientific literature to justify or support the practice of closing a surgical wound with both subcuticular suture and adhesive surgical tape.

  8. Bronchial closure methods and risks for bronchopleural fistula in pulmonary resections: how a surgeon may choose the optimum method?

    PubMed

    Uçvet, Ahmet; Gursoy, Soner; Sirzai, Serdar; Erbaycu, Ahmet E; Ozturk, Ali A; Ceylan, Kenan C; Kaya, Seyda O

    2011-04-01

    There is debate about which bronchial closure technique is the best to prevent bronchopleural fistulas (BPFs). We aim to assess the effect of bronchial closure procedures and patients' characteristics on BPF occurrence in pulmonary resections. Bronchial closures in 625 consecutive patients were assessed. Stumps were closed by manual suturing in 204 and by mechanical stapling in 421 cases. In the mechanical stapling group, stapling supported by manual suture was performed in 170 cases. BPFs occurred in 3.8%. Of these, stapling was used in 5.0%, whereas manual suturing was used in 1.5% (P=0.04). BPFs were more prevalent among patients who had undergone pneumonectomy (P<0.01), right pneumonectomy (P<0.01), stapler closure (P<0.01), patients with co-factors (P<0.01), and patients who had undergone preoperative neo-adjuvant (P=0.01) or postoperative adjuvant therapy (P=0.03). There was no difference in the frequency of BPF between patients with and without adjuvant support in the stapling group. The optimum bronchial closure method has to be chosen by considering the patient and bronchus based characteristics. This has to be assessed carefully, especially in pneumonectomy and co-factors. The manual closure seems to be the more preferable method in risky patients. An additive support suture on the bronchial stump does not decrease the risk of BPF.

  9. Granulation tissue formation at the bronchial stump is reduced after stapler closure in comparison to suture closure in dogs.

    PubMed

    Izumi, Yotaro; Kawamura, Masafumi; Gika, Masatoshi; Nomori, Hiroaki

    2010-03-01

    The aim of this study was to compare the morphology of the bronchial stump after lobectomy between mechanical stapler closure and manual suture closure. The effect of fibrin glue application on each method of closure was also observed. Right upper lobectomy was performed in beagles (n=31) using staplers (ST group) or sutures (SU group). In a separate experiment, fibrin glue was sprayed onto the stump after each respective method of closure. After one week, the stump region was examined macroscopically, and also by histology. chi(2)-Test and Mann-Whitney test were used for comparative analysis. The incidence of adhesion formation between the surrounding tissues was significantly reduced in the ST group in comparison to the SU group (22 vs. 80%, P=0.04). The thickness of granulation tissue over the stump was significantly reduced in the ST group in comparison to the SU group (0.8+/-0.2 vs. 2.5+/-0.3 mm, P<0.0001). Vessel density in the granulation tissue was also significantly reduced in the ST group in comparison to the SU group (6+/-2 vs. 16+/-2, P=0.003). Fibrin glue application after stapler closure significantly increased the incidence of adhesion formation, granulation tissue thickness, and vessel density in the granulation tissue over the stump.

  10. Transcatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.

    PubMed

    Djer, Mulyadi M; Idris, Nikmah S; Alwi, Idrus; Wijaya, Ika P

    2014-07-01

    Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the most appropriate technique and device. We would like to report a case of transcatheter closure of residual VSD post Rastelli operation in a patient with double outlet right ventricle (DORV), sub-aortic VSD, severe infundibulum pulmonary stenosis (PS) and single coronary artery. The patient had undergone operations for four times, but he still had intractable heart failure that did not response to medications. On the first attempt. we closed the VSD using a VSD occluder, unfortunately the device embolized into the descending aorta, but fortunately we was able to snare it out. Then we decided to close the VSD using a patent ductus arteriosus (PDA occluder). On transesophageal echocardiography (TEE) and angiography evaluation, the device position was stable. Post transcatheter VSD closure, the patient clinical condition improved significantly and he could finally be discharged after a long post-surgery hospitalization. Based on this experience we concluded that the transcatheter closure of residual VSD in complex CHD using PDA occluder could be an effective alternative treatment.

  11. A Practical Scoring System to Select Optimally Sized Devices for Percutaneous Patent Foramen Ovale Closure.

    PubMed

    Venturini, Joseph M; Retzer, Elizabeth M; Estrada, J Raider; Mediratta, Anuj; Friant, Janet; Nathan, Sandeep; Paul, Jonathan D; Blair, John; Lang, Roberto M; Shah, Atman P

    2016-10-01

    Patent foramen ovale (PFO) has been linked to cryptogenic stroke, and closure has been reported to improve clinical outcomes. However, there are no clear guidelines to direct device sizing. This study sought to use patient characteristics and echocardiographic findings to create a prediction score for device sizing. This was a retrospective review of patients undergoing percutaneous PFO closure at our institution between July 2010 and December 2014. Demographic and clinical characteristics were recorded, and all pre- and intraprocedural echocardiography results were evaluated. Thirty-six patients underwent percutaneous PFO closure during the study period. All procedures were performed using an Amplatzer Septal Occluder "Cribriform" (ASOC) device in one of three disc diameters: 25, 30, or 35 mm. Closure was indicated for cryptogenic stroke/transient ischemic attack in 75% of cases. Every case (100%) was successful with durable shunt correction at the 6-month follow-up without complications of erosion or device embolization. The presence of atrial septal aneurysm (ASA) ( p = 0.027) and PFO tunnel length >10 mm ( p = 0.038) were independently associated with increased device size. A scoring system of 1 point for male sex, 1 point for ASA, and 1 point for PFO tunnel >10 mm long was associated with the size of closure device implanted ( p = 0.006). A simple scoring system may be used to select an optimally sized device for percutaneous PFO closure using the ASOC device.

  12. Reconstructive methods in Mohs micrographic surgery in Uruguay: A bidirectional descriptive cohort analysis.

    PubMed

    Navarrete, J; Magliano, J; Martínez, M; Bazzano, C

    2018-04-01

    The primary goal of Mohs micrographic surgery (MMS) is to completely excise a cancerous lesion and a wide range of reconstructive techniques of varying complexity are used to close the resulting wound. In this study, we performed a descriptive analysis of patients who underwent MMS, with a focus on wound closure methods. We conducted a bidirectional descriptive cohort analysis of all MMS procedures performed by a single surgeon between November 2013 and April 2016. Cosmetic outcomes were photographically assessed by a dermatologist after a minimum follow-up of 90 days. We analyzed 100 MMS procedures in 71 patients with a median age of 73 years. The tumors were basal cell carcinoma (70%), squamous cell carcinoma (29%), and dermatofibrosarcoma protuberans (1%); 75% were located on the head and neck. The reconstructive techniques used were flap closure (48%), simple closure (36%), closure by second intention (11%), and other (5%). Cosmetic outcomes were assessed for 70 procedures (47 patients) and the results were rated as excellent in 20% of cases, very good in 40%, good in 20%, moderate in 17%, and bad/very bad in 2.9%. No significant associations were observed between cosmetic outcome and sex, Fitzpatrick skin type, hypertension, diabetes mellitus, or smoking. Worse outcomes, however, were significantly associated with larger tumor areas and defects, location on the trunk, and flap and second-intention closure. Although there was a tendency to use simple wound closure for lesions located on the trunk and surgical defects of under 4.4cm 2 , the choice of reconstructive technique should be determined by individual circumstances with contemplation of clinical and tumor-related factors and the preference and experience of the surgeon. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Role of macular hole angle in macular hole closure.

    PubMed

    Chhablani, Jay; Khodani, Mitali; Hussein, Abdullah; Bondalapati, Sailaja; Rao, Harsha B; Narayanan, Raja; Sudhalkar, Aditya

    2015-12-01

    To evaluate correlation of various spectral-domain optical coherence tomography (SD-OCT) parameters including macular hole angle as well as various indices with anatomical and visual outcomes after idiopathic macular hole repair surgery. Retrospective study of 137 eyes of 137 patients who underwent idiopathic macular hole repair surgery between January 2008 and January 2014 was performed. Various qualitative parameters such as presence of vitreomacular traction, epiretinal membrane and cystic edges at the macular hole as well as quantitative parameters such as maximum diameter on the apex of the hole, minimum diameter between edges, nasal and temporal vertical height, longest base diameter and macular hole angle between the retinal edge and the retinal pigment epithelium were noted. Indices including hole form factor, Macular Hole Index (MHI), Diameter Hole Index and Tractional Hole Index (THI) were calculated. Univariate and multivariate regression analysis was performed separately for final visual acuity (VA) and type of closure as dependent variable in relation to SD-OCT parameters as independent variables. On multivariate regression only minimum diameter between edges (p≤0.01) and longest base diameter (p≤0.03) were correlated significantly with both, type 1 closure and final VA. Among the indices, significant correlation of MHI (p=0.009) was noted with type of closure and that of THI with final VA (p=0.017). Our study shows no significant correlation between macular hole angle and hole closure. Minimum diameter between the edges and longest diameter of the hole are best predictors of hole closure and postoperative VA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Post-Closure Inspection Report for the Tonopah Test Range, Nevada, for Calendar Year 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silvas, A. J.

    2014-03-03

    This report provides the results of the annual post-closure inspections conducted at the closed Corrective Action Units (CAUs) located on the Tonopah Test Range (TTR), Nevada. This report covers calendar year 2013 and includes inspection and repair activities completed at the following CAUs: • CAU 400: Bomblet Pit and Five Points Landfill (TTR) • CAU 407: Roller Coaster RadSafe Area (TTR) • CAU 424: Area 3 Landfill Complexes (TTR) • CAU 453: Area 9 UXO Landfill (TTR) • CAU 487: Thunderwell Site (TTR) Inspections were conducted according to the post-closure plans in the approved Closure Reports and subsequent correspondence withmore » the Nevada Division of Environmental Protection. The post-closure inspection plans and subsequent correspondence modifying the requirements for each CAU are included in Appendix B. The inspection checklists are included in Appendix C. Field notes are included in Appendix D. Photographs taken during inspections are included in Appendix E. The annual post-closure inspections were conducted on May 14, 2013. Maintenance was performed at CAU 400, CAU 424, and CAU 453. At CAU 400, animal burrows were backfilled. At CAU 424, erosion repairs were completed at Landfill Cell A3-3, subsidence was repaired at Landfill Cell A3-4, and additional lava rock was placed in high-traffic areas to mark the locations of the surface grade monuments at Landfill Cell A3-3 and Landfill Cell A3-8. At CAU 453, two areas of subsidence were repaired and animal burrows were backfilled. Vegetation monitoring was performed at the CAU 400 Five Points Landfill and CAU 407 in June 2013. The vegetation monitoring report is included in Appendix F.« less

  15. Patent foramen ovale closure following cryptogenic stroke or transient ischaemic attack: Long-term follow-up of 301 cases.

    PubMed

    Mirzaali, Mikaeil; Dooley, Maureen; Wynne, Dylan; Cooter, Nina; Lee, Lorraine; Haworth, Peter; Saha, Romi; Gainsborough, Nicola; Hildick-Smith, David

    2015-11-15

    Patent foramen ovale has been identified as a conduit for paradoxical embolism resulting in cryptogenic stroke or transient ischemic attack (TIA). We aimed to establish rates of death, recurrent stroke or TIA among patients undergoing PFO closure for stroke or TIA at our unit. A retrospective analysis of all PFO closure patients was performed between May 2004 and January 2013. Follow up was performed by mortality tracing using the Medical Research Information Service of the Office of National Statistics. With regard to stroke or TIA recurrence, written consent forms and questionnaires were mailed with follow up telephone calls. Medical notes and imaging records were consulted where adverse events were noted. 301 patients aged 48.6 ± 11.0 years, 54.4% male, with ≥1 thromboembolic neurovascular event had percutaneous PFO closure with one of eight devices, with successful implantation in 99% of cases. Follow-up duration was 40.2 ± 26.2 months (range 1.3-105.3); complete in 301 patients for mortality (100%) and 283 patients (94.0%) for neurovascular events. Two patients died during follow-up (respiratory failure n = 1; road traffic accident n = 1). Recurrent stroke (MRI or CT confirmed) was observed in five patients (0.5%; 0.55 per 100 person-years) and TIA in 9 (1.1%; 0.98 per 100 person-years). Atrial fibrillation requiring treatment was documented in 14 patients (1.7%). Percutaneous PFO closure in patients with cryptogenic stroke or TIA is a safe treatment with a low incidence of procedural complications and recurrent neurovascular events. Registry data like these may help to demonstrate the utility of PFO closure in stroke. © 2015 Wiley Periodicals, Inc.

  16. Automated method for determining Instron Residual Seal Force of glass vial/rubber closure systems.

    PubMed

    Ludwig, J D; Nolan, P D; Davis, C W

    1993-01-01

    Instron Residual Seal Force (IRSF) of glass vial/rubber closure systems was determined using an Instron 4501 Materials Testing System. Computer programs were written to process raw data and calculate IRSF values. Preliminary experiments indicated both the appearance of the stress-deformation curves and precision of the derived IRSF values were dependent on the internal dimensions and top surface geometry of the cap anvil. Therefore, a series of five cap anvils varying in shape and dimensions were machined to optimize performance and precision. Vials capped with West 4416/50 PURCOAT button closures or Helvoet compound 6207 lyophilization closures were tested with each cap anvil. Cap anvils with spherical top surfaces and narrow internal dimensions produced more precise results and more uniform stress-deformation curves than cap anvils with flat top surfaces and wider internal dimensions.

  17. A 40-year-old woman with cauda equina syndrome caused by rectothecal fistula arising from an anterior sacral meningocele.

    PubMed

    Bergeron, Eric; Roux, Alain; Demers, Jacques; Vanier, Laurent E; Moore, Lynne

    2010-11-01

    We present a rare case of a rectothecal fistula arising from an anterior sacral meningocele in a patient with Currarino syndrome. The patient was a 40-year-old woman presenting with cauda equina syndrome and ascending meningitis. The meningocele was removed using an anterior abdominal approach. A sigmoid resection was performed with rectal on-table antegrade lavage followed by closure of the rectal fistula, closure of the rectal stump, and proximal colostomy. Closure of the sacral deficit was carried out by suturing a strip of well-vascularized omentum and fibrin glue. We discuss the characteristics, management, and evolution of this unusual case. Prompt surgical management using an anterior approach, resection of the sac, closure of the sacral deficit, and fecal diversion resulted in a satisfactory outcome.

  18. 77 FR 4550 - Promising and Practical Strategies to Increase Postsecondary Success

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-30

    ... Education. Appendix A: Standard Keywords and Tags Accelerated Learning Achievement Gap Closure Adult Education Affordability Assessment Technology Badges Basic Skills Blended Learning Block Scheduling [[Page... Collection/Use Degree Attainment Developmental/Remedial Education Digital Materials Dual Degrees Earn and...

  19. 40 CFR 265.118 - Post-closure plan; amendment of plan.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the wastes, application of advanced technology, or alternative disposal, treatment, or re-use.... 265.118 Section 265.118 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT...

  20. BACTERIA, BEACHES AND SWIMMABLE WATERS: INTRODUCING VIRTUAL BEACH

    EPA Science Inventory

    Safe beaches meet water quality standards and are valued for their aesthetics and the recreational opportunities that they afford. In the United States recreational water quality assessments and beach closure decisions are presently based on samples of enterococci or Escherichia ...

  1. Degrees of Closure and Economic Success in the Norwegian Labour Market: Field of Study and Non-Western Immigrant Performance

    ERIC Educational Resources Information Center

    Drange, Ida

    2016-01-01

    This article compares outcomes in the Norwegian labour market for non-Western immigrants and majority colleagues with professional or master's degrees within three different fields of study: health science, social science and natural science. Professions have a higher degree of occupational closure, which may entail that non-Western immigrants…

  2. Liver Resections Combined with Closure of Loop Ileostomies: A Retrospective Analysis

    PubMed Central

    Lordan, Jeffrey T.; Riga, Angela T.; Karanjia, Nariman D.

    2008-01-01

    Background. The management of patients with colorectal liver metastases and loop ileostomies remains controversial. This study was performed to assess the outcome of combined liver resection and loop ileostomy closure. Methods. Analysis of prospectively collected perioperative data, including morbidity and mortality, of 283 consecutive hepatectomies for colorectal liver metastases was undertaken. Consecutive liver resections were performed from 1996 to 2006 in one centre by a single surgeon (NDK). Fourteen of these patients had combined liver resection and ileostomy closure. Case-matched analysis was undertaken. Results. Six (2.2%) patients died in the hepatectomy only group and none died in the combined group. There was no difference in operative blood loss between the two groups (0.09). Perioperative morbidity was 36% in the combined group and 23% in the hepatectomy alone group (P = 0.33). Mean hospital stay was 14 days in the combined group and 11 days in the hepatectomy only group (P = 0.046). Case-matched analysis showed a significant increase in hospital stay (P = 0.03) and complications (P = 0.049) in the combined group. Conclusion. In patients with CRLM, combined liver resection and closure of ileostomy may be associated with a higher operative morbidity and a prolonged hospital stay. PMID:19096524

  3. Comparing approaches to screening for angle closure in older Chinese adults

    PubMed Central

    Andrews, J; Chang, D S; Jiang, Y; He, M; Foster, P J; Munoz, B; Kashiwagi, K; Friedman, D S

    2012-01-01

    Aims Primary angle-closure glaucoma is expected to account for nearly 50% of bilateral glaucoma blindness by 2020. This study was conducted to assess the performance of the scanning peripheral anterior chamber depth analyzer (SPAC) and limbal anterior chamber depth (LACD) as screening methods for angle closure. Methods This study assessed two clinical populations to compare SPAC, LACD, and gonioscopy: the Zhongshan Angle-closure Prevention Trial, from which 370 patients were eligible as closed-angle participants and the Liwan Eye Study, from which 72 patients were selected as open-angle controls. Eligible participants were assessed by SPAC, LACD, and gonioscopy. Results Angle status was defined by gonioscopy. Area under the receiver operating characteristic curve (AUROC) for SPAC was 0.92 (0.89–0.95) whereas AUROC for LACD was 0.94 (0.92–0.97). Using conventional cutoff points, sensitivity/specificity was 93.0%/70.8% for SPAC and 94.1%/87.5% for LACD. Sequential testing using both SPAC and LACD increased the specificity to 94.4% and decreased the sensitivity to 87.0%. Conclusion SPAC has significantly lower specificity than LACD measurement using conventional cutoffs but interpretation of the findings can be performed by modestly trained personnel. PMID:21997356

  4. Secure closure of the tracheal incision after natural orifice transluminal endoscopic surgery with a surgical sealant (CoSeal).

    PubMed

    Liu, Yun-Hen; Wu, Yi-Cheng; Chen, Tzu-Ping; Ko, Po-Jen

    2011-09-01

    To evaluate the effectiveness of surgical sealant (CoSeal) in sealing the tracheal assess sites after transtracheal thoracoscopy. Two dogs underwent transtracheal thoracic exploration and pericardial window creation. The thoracic cavity was approached with flexible bronchoscope through a 9-mm tracheal incision. The pericardial window was performed with a needle knife via the working channel of the bronchoscope, and the tracheal assess site was closed with CoSeal using a rubber catheter. The integrity of tracheal healing was evaluated under positive pressure ventilation. Transtracheal creation of pericardial window and closure of tracheal incision with CoSeal was successfully performed in both dogs. There was no evidence of air leaks from the chest tube during positive pressure ventilation. Autopsy revealed no injury to the mediastinum and intrathoracic structure. Endoscopic closure of tracheal access site of NOTES with CoSeal appears to be a feasible technique.

  5. Morphologic Characteristics and Relating Factors to the Need of Technical Modification in Transcatheter Closure of Large Atrial Septal Defect (≥25 mm)

    PubMed Central

    Park, Su-Jin; Kim, Nam Kyun; Kim, Jung Ok; Yoo, Byung Won; Sul, Jun Hee

    2010-01-01

    Background and Objectives The rigid coupling between the delivery wire and the right atrial disk has been occasionally encountered during transcatheter closure of atrial septal defect (ASD). Therefore the device frequently makes a perpendicular angle, and the leading edge of left atrial disk slips through the defect and prolapses into right atrium (RA) before it is properly placed in the septum. The purpose of this study is to investigate relating factors to the need of technical modification in transcatheter closure of large ASD and to evaluate relevant morphologic characteristics of atrial septal rim in this situation. Subjects and Methods From July, 2003 to May, 2007, 312 patients underwent transcatheter occlusion of ASD with Amplatzer Septal Occluder® (ASO, AGA medical corporation, Golden Valley, MN, USA) at Yonsei Cardiovascular Center and among them 109 patients had large ASD (≥25 mm) and these patients were enrolled in our study. Patients were divided into two groups according to the deploying methods of the device (Group I: standard method, Group II: modified methods). Assessments of the defects and its surrounding rims were made by echocardiography. Results There were no differences between 2 groups in age, body weight and height except for balloon-stretched diameter (stop-flow technique) and device size. Group II patients with modified methods showed larger balloon-stretched diameter and device size than group I patients with standard method. The mean length of anterosuperior (AS) rim in group II was significantly shorter than group I (p<0.05). As the size of the device used in procedure increased, there was a trend towards increase in the need of modified methods. Conclusion This study shows that AS rim deficiency and the size of ASD may be the relating factors to the need of technical modification in transcatheter closure of ASD. Therefore, when the initial try with standard method is not successful in large ASD with deficient AS rim, we suggest that changing strategy of implantation may save time and efforts and possibly reduce the risk of complications associated with prolonged procedure. PMID:20421960

  6. Precipitation Depth-Duration-Frequency Analysis for the Nevada National Security Site and Surrounding Areas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Li; Miller, Julianne J.

    Accurate precipitation frequency data are important for Environmental Management Soils Activities on the Nevada National Security Site (NNSS). These data are important for environmental assessments performed for regulatory closure of Soils Corrective Action Unit (CAU) Sites, as well as engineering mitigation designs and post-closure monitoring strategies to assess and minimize potential contaminant migration from Soils CAU Sites. Although the National Oceanic and Atmospheric Administration (NOAA) Atlas 14 (Bonnin et al., 2011) provides precipitation frequency data for the NNSS area, the NNSS-specific observed precipitation data were not consistent with the NOAA Atlas 14 predicted data. This is primarily due to themore » NOAA Atlas 14 products being produced from analyses without including the approximately 30 NNSS precipitation gage records, several of which approach or exceed 50 year of record. Therefore, a study of precipitation frequency that incorporated the NNSS precipitation gage records into the NOAA Atlas 14 dataset, was performed specifically for the NNSS to derive more accurate site-specific precipitation data products. Precipitation frequency information, such as the depth-duration-frequency (DDF) relationships, are required to generate synthetic standard design storm hydrographs and assess actual precipitation events. In this study, the actual long-term NNSS precipitation gage records, some of which are the longest gage records in southern and central Nevada, were analyzed to allow for more accurate precipitation DDF estimates to be developed for the NNSS. Gridded maps of precipitation frequency for the NNSS and surrounding areas were then produced.« less

  7. One hospital, one appendectomy: The cost effectiveness of a standardized doctor's preference card.

    PubMed

    Skarda, David E; Rollins, Michael; Andrews, Seth; McFadden, Molly; Barnhart, Doug; Meyers, Rebecka; Scaife, Eric

    2015-06-01

    Appendicitis in children provides a unique opportunity to explore changes that reduce variation, reduce cost, and improve value. In this study we sought to evaluate the effectiveness of standardization of surgical technique and intraoperative disposable device utilization for laparoscopic appendectomy among all surgeons at a tertiary children's hospital. All 6 surgeons at our tertiary children's hospital agreed to standardize to a single technique of performing a laparoscopic appendectomy. We collected data on all pediatric patients who had a laparoscopic appendectomy following implementation of the uniform doctor's preference card (DPC) (March 1, 2013 to February 28, 2014) and compared them to a historical control group. Implementation of the uniform DPC decreased the device cost per appendectomy from $844.11 to $305.32. Operative times (skin incision to skin closure) were 34.8 minutes prior to the uniform DPC and 37.0 minutes using the uniform DPC. There were no significant differences in postappendectomy outcomes. We have demonstrated that implementation of a uniform DPC and technical standardization for laparoscopic appendectomy can significantly reduce cost. Furthermore, this can occur without dramatically increasing operative times, length of stay, or postoperative complications. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Closure Report for the 92-Acre Area and Corrective Action Unit 111: Area 5 WMD Retired Mixed Waste Pits, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2012-02-21

    This Closure Report (CR) presents information supporting closure of the 92-Acre Area, which includes Corrective Action Unit (CAU) 111, 'Area 5 WMD Retired Mixed Waste Pits.' This CR provides documentation supporting the completed corrective actions and confirmation that the closure objectives were met. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) (FFACO, 1996 [as amended March 2010]). Closure activities began in January 2011 and were completed in January 2012. Closure activities were conducted according to Revision 1 of the Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) for the 92-Acre Area and CAU 111more » (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2010). The following closure activities were performed: (1) Construct an engineered evapotranspiration cover over the boreholes, trenches, and pits in the 92-Acre Area; (2) Install use restriction (UR) warning signs, concrete monuments, and subsidence survey monuments; and (3) Establish vegetation on the covers. UR documentation is included as Appendix C of this report. The post-closure plan is presented in detail in Revision 1 of the CADD/CAP for the 92-Acre Area and CAU 111, and the requirements are summarized in Section 5.2 of this document. When the next request for modification of Resource Conservation and Recovery Act Permit NEV HW0101 is submitted to the Nevada Division of Environmental Protection (NDEP), the requirements for post-closure monitoring of the 92-Acre Area will be included. NNSA/NSO requests the following: (1) A Notice of Completion from NDEP to NNSA/NSO for closure of CAU 111; and (2) The transfer of CAU 111 from Appendix III to Appendix IV, Closed Corrective Action Units, of the FFACO.« less

  9. Transcatheter closure of patent foramen ovale for secondary prevention of ischemic stroke: Quantitative synthesis of pooled randomized trial data.

    PubMed

    Hakeem, Abdul; Cilingiroglu, Mehmet; Katramados, Angelos; Boudoulas, Konstantinos Dean; Iliescu, Cezar; Gundogdu, Betul; Marmagkiolis, Konstantinos

    2018-01-14

    To evaluate the safety and efficacy of percutaneous device closure of patent foramen ovale (PFO) for secondary prevention of ischemic stroke BACKGROUND: Stroke remains the leading cause of serious long-term disability in the United States. The effectiveness of a percutaneous PFO closure in the prevention of recurrent cryptogenic strokes has not been established. We performed a literature search using PubMed, EMBASE, Cochrane Central Register of Controlled Trials, Google Scholar, and Internet-based sources from January 2003 to September 2017. Randomized controlled trails (RCTs) comparing percutaneous PFO closure to medical therapy alone. Five RCTs (CLOSURE I, PC Trial, REDUCE, RESPECT, and CLOSE) with 1,829 patients in the device group and 1,611 patients in the medical group met inclusion criteria. The cumulative incidence of recurrent stroke was 2.02% in the PFO closure arm and 4.4% in the medical therapy group (RR 0.42, 95%CI 0.20, 0.91; P = 0.03). There was no difference in the incidence of death [0.7% vs. 0.9%; RR 0.76 (95% CI 0.35, 1.64), P = 0.49] or adverse events during the follow-up period [24.6% vs. 23.7% (RR 1.03; 95% CI 0.91, 1.16), P = 0.65] between the closure and medical therapy groups. Incidence of atrial fibrillation was significantly higher in closure group compared to medical therapy [4% vs. 0.6% (RR 4.73; 95% CI 2.09, 10.70), P = 0.0002]. The comparative effectiveness of PFO closure (compared to medical therapy) was significantly more pronounced in those younger than 45 years, males, larger shunts and disc design platforms (P < 0.05). Based on the results of this analysis of randomized trial data, percutaneous PFO closure appears to be a safe and effective therapeutic option for the secondary prevention of ischemic stroke in patients with PFO and cryptogenic stroke. © 2018 Wiley Periodicals, Inc.

  10. Closure Report for Corrective Action Unit 536: Area 3 Release Site, Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    Corrective Action Unit (CAU) 536 is located in Area 3 of the Nevada Test Site. CAU 536 is listed in the Federal Facility Agreement and Consent Order of 1996 as Area 3 Release Site, and comprises a single Corrective Action Site (CAS): {sm_bullet} CAS 03-44-02, Steam Jenny Discharge The Nevada Division of Environmental Protection (NDEP)-approved corrective action alternative for CAS 03-44-02 is clean closure. Closure activities included removing and disposing of total petroleum hydrocarbon (TPH)- and polyaromatic hydrocarbon (PAH)-impacted soil, soil impacted with plutonium (Pu)-239, and concrete pad debris. CAU 536 was closed in accordance with the NDEP-approved CAU 536more » Corrective Action Plan (CAP), with minor deviations as approved by NDEP. The closure activities specified in the CAP were based on the recommendations presented in the CAU 536 Corrective Action Decision Document (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2004). This Closure Report documents CAU 536 closure activities. During closure activities, approximately 1,000 cubic yards (yd3) of hydrocarbon waste in the form of TPH- and PAH-impacted soil and debris, approximately 8 yd3 of Pu-239-impacted soil, and approximately 100 yd3 of concrete debris were generated, managed, and disposed of appropriately. Additionally, a previously uncharacterized, buried drum was excavated, removed, and disposed of as hydrocarbon waste as a best management practice. Waste minimization techniques, such as the utilization of laboratory analysis to characterize and classify waste streams, were employed during the performance of closure« less

  11. A Scandcleft randomised trials of primary surgery for unilateral cleft lip and palate: 1. Planning and management.

    PubMed

    Semb, Gunvor; Enemark, Hans; Friede, Hans; Paulin, Gunnar; Lilja, Jan; Rautio, Jorma; Andersen, Mikael; Åbyholm, Frank; Lohmander, Anette; Shaw, William; Mølsted, Kirsten; Heliövaara, Arja; Bolund, Stig; Hukki, Jyri; Vindenes, Hallvard; Davenport, Peter; Arctander, Kjartan; Larson, Ola; Berggren, Anders; Whitby, David; Leonard, Alan; Neovius, Erik; Elander, Anna; Willadsen, Elisabeth; Bannister, R Patricia; Bradbury, Eileen; Henningsson, Gunilla; Persson, Christina; Eyres, Philip; Emborg, Berit; Kisling-Møller, Mia; Küseler, Annelise; Granhof Black, Birthe; Schöps, Antje; Bau, Anja; Boers, Maria; Andersen, Helene Søgaard; Jeppesen, Karin; Marxen, Dorte; Paaso, Marjukka; Hölttä, Elina; Alaluusua, Suvi; Turunen, Leena; Humerinta, Kirsti; Elfving-Little, Ulla; Tørdal, Inger Beate; Kjøll, Lillian; Aukner, Ragnhild; Hide, Øydis; Feragen, Kristin Billaud; Rønning, Elisabeth; Skaare, Pål; Brinck, Eli; Semmingsen, Ann-Magritt; Lindberg, Nina; Bowden, Melanie; Davies, Julie; Mooney, Jeanette; Bellardie, Haydn; Schofield, Nina; Nyberg, Jill; Lundberg, Maria; Karsten, Agneta Linder-Aronson; Larson, Margareta; Holmefjord, Anders; Reisæter, Sigvor; Pedersen, Nina-Helen; Rasmussen, Therese; Tindlund, Rolf; Sæle, Paul; Blomhoff, Reidunn; Jacobsen, Gry; Havstam, Christina; Rizell, Sara; Enocson, Lars; Hagberg, Catharina; Najar Chalien, Midia; Paganini, Anna; Lundeborg, Inger; Marcusson, Agneta; Mjönes, Anna-Britta; Gustavsson, Annica; Hayden, Christine; McAleer, Eilish; Slevan, Emma; Gregg, Terry; Worthington, Helen

    2017-02-01

    Longstanding uncertainty surrounds the selection of surgical protocols for the closure of unilateral cleft lip and palate, and randomised trials have only rarely been performed. This paper is an introduction to three randomised trials of primary surgery for children born with complete unilateral cleft lip and palate (UCLP). It presents the protocol developed for the trials in CONSORT format, and describes the management structure that was developed to achieve the long-term engagement and commitment required to complete the project. Ten established national or regional cleft centres participated. Lip and soft palate closure at 3-4 months, and hard palate closure at 12 months served as a common method in each trial. Trial 1 compared this with hard palate closure at 36 months. Trial 2 compared it with lip closure at 3-4 months and hard and soft palate closure at 12 months. Trial 3 compared it with lip and hard palate closure at 3-4 months and soft palate closure at 12 months. The primary outcomes were speech and dentofacial development, with a series of perioperative and longer-term secondary outcomes. Recruitment of 448 infants took place over a 9-year period, with 99.8% subsequent retention at 5 years. The series of reports that follow this introductory paper include comparisons at age 5 of surgical outcomes, speech outcomes, measures of dentofacial development and appearance, and parental satisfaction. The outcomes recorded and the numbers analysed for each outcome and time point are described in the series. ISRCTN29932826.

  12. The impact of the fecal stream and stasis on immunologic reactions in ileal pouch after restorative proctocolectomy for ulcerative colitis: a prospective, pilot study.

    PubMed

    Yamamoto, Takayuki; Umegae, Satoru; Kitagawa, Tatsushi; Matsumoto, Koichi

    2005-10-01

    The etiology of pouch inflammation after restorative proctocolectomy is unknown. The fecal stream and immunological reactions are potential pathological factors. This study was performed to examine the impact of the fecal stream and stasis on immunological reactions in the pouch. Patients who underwent a restorative proctocolectomy with a covering ileostomy for ulcerative colitis were studied. Mucosal biopsy specimens were obtained from both the pouch and the proximal ileum at the time of ileostomy closure, and 3, 6, and 12 months after ileostomy closure. As a control group, normal ileal biopsies were obtained from patients with colonic polyps. At the time of ileostomy closure, mucosal interleukin-1beta, interleukin-6, interleukin-8, and tumor necrosis factor-alpha levels in the pouch and the proximal ileum were not significantly different from those in the normal control group. At 3 months after ileostomy closure, the mucosal cytokine levels in the pouch increased significantly compared with those at ileostomy closure, and their levels were significantly higher than those in the proximal ileum. At 6 and 12 months after ileostomy closure, the mucosal cytokine levels in the pouch did not change significantly compared with those at 3 months after ileostomy closure. The mucosal cytokine levels in the proximal ileum did not change significantly during the entire study. The immunological reactions in the pouch occurred soon after ileostomy closure, and continued for at least 1 yr. The fecal stream and stasis play an important part in the pathogenesis of immunological reactions in the ileal pouch.

  13. Post-Closure Strategy for Use-Restricted Sites on the Nevada National Security Site, Nevada Test and Training Range, and Tonopah Test Range, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silvas, A. J.

    The purpose of this Post-Closure Strategy is to provide a consistent methodology for continual evaluation of post-closure requirements for use-restricted areas on the Nevada National Security Site (NNSS), Nevada Test and Training Range (NTTR), and Tonopah Test Range (TTR) to consolidate, modify, or streamline the program. In addition, this document stipulates the creation of a single consolidated Post-Closure Plan that will detail the current post-closure requirements for all active use restrictions (URs) and outlines its implementation and subsequent revision. This strategy will ensure effective management and control of the post-closure sites. There are currently over 200 URs located on themore » NNSS, NTTR, and TTR. Post-closure requirements were initially established in the Closure Report for each site. In some cases, changes to the post-closure requirements have been implemented through addenda, errata sheets, records of technical change, or letters. Post-closure requirements have been collected from these multiple sources and consolidated into several formats, such as summaries and databases. This structure increases the possibility of inconsistencies and uncertainty. As more URs are established and the post-closure program is expanded, the need for a comprehensive approach for managing the program will increase. Not only should the current requirements be obtainable from a single source that supersedes all previous requirements, but the strategy for modifying the requirements should be standardized. This will enable more effective management of the program into the future. This strategy document and the subsequent comprehensive plan are to be implemented under the assumption that the NNSS and outlying sites will be under the purview of the U.S. Department of Energy, National Nuclear Security Administration for the foreseeable future. This strategy was also developed assuming that regulatory control of the sites remains static. The comprehensive plan is not intended to be a permanent long-term stewardship plan. However, it is intended to clarify requirements and identify components to effectively manage the sites until regulatory requirements are met or management of the site changes. The Environmental Management Program is required to manage these sites until the NNSS Environmental Restoration program is completed, currently planned for 2030. Prior to completion of the Environmental Restoration program, additional planning will be conducted to ensure that long-term stewardship of the sites is maintained. A comprehensive post-closure plan can be transitioned effectively into any future site-wide long-term stewardship program that may be developed. Therefore, the post-closure plan will include current aspects of the post-closure program that are also important aspects of long-term stewardship, including the following: • Management of physical and engineering controls such as fences, signs, and soil covers • Management of institutional and administrative controls such as use restrictions and real estate systems • Management of monitoring and maintenance programs • Management of information related to the sites such as geographic information system data and related documentation The strategy will also allow for periodic review and modification of any aspect of the program to ensure continued effectiveness.« less

  14. Stapedotomy in osteogenesis imperfecta: a prospective study of 32 consecutive cases.

    PubMed

    Vincent, Robert; Wegner, Inge; Stegeman, Inge; Grolman, Wilko

    2014-12-01

    To prospectively evaluate hearing outcomes in patients with osteogenesis imperfecta undergoing primary stapes surgery and to isolate prognostic factors for success. A nonrandomized, open, prospective case series. A tertiary referral center. Twenty-five consecutive patients who underwent 32 primary stapedotomies for osteogenesis imperfecta with evidence of stapes fixation and available postoperative pure-tone audiometry. Primary stapedotomy with vein graft interposition and reconstruction with a regular Teflon piston or bucket handle-type piston. Preoperative and postoperative audiometric evaluation using conventional 4-frequency (0.5, 1, 2, and 4 kHz) audiometry. Air-conduction thresholds, bone-conduction thresholds, and air-bone gap were measured. The overall audiometric results as well as the results of audiometric evaluation at 3 months and at least 1 year after surgery were used. Overall, postoperative air-bone gap closure to within 10 dB was achieved in 88% of cases. Mean (standard deviation) gain in air-conduction threshold was 22 (9.4) dB for the entire case series, and mean (standard deviation) air-bone gap closure was 22 (9.0) dB. Backward multivariate logistic regression showed that a model with preoperative air-bone gap closure and intraoperatively established incus length accurately predicts success after primary stapes surgery. Stapes surgery is a feasible and safe treatment option in patients with osteogenesis imperfecta. Success is associated with preoperative air-bone gap and intraoperatively established incus length.

  15. Closure Report for Corrective Action Unit 568: Area 3 Plutonium Dispersion Sites Nevada National Security Site, Nevada, Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, Patrick

    The purpose of this CR is to provide documentation and justification that no further corrective action is needed for the closure of CAU 568 based on the implementation of corrective actions. This includes a description of closure activities that were performed and an evaluation of the verification data. The CAP (NNSA/NFO, 2016a) and ROTC-1 (NNSA/NFO, 2016c) provide information relating to the selection of CAAs and the reasoning behind their selection. The CADD (NNSA/NFO, 2015) identifies the release sites that require additional corrective action and presents information supporting the selection of CAAs.

  16. The off-label use of the Amplatzer muscular VSD occluder for large patent ductus arteriosus: a case report and review.

    PubMed

    Cubeddu, Roberto J; Babin, Ivan; Inglessis, Ignacio

    2014-07-01

    A percutaneous approach to the closure of patent ductus arteriosus (PDA) is the preferred procedure in the majority of cases. However, there is little experience with percutaneous closure of unusually large PDA. We report the case of a 28-year-old female with moderate left ventricular dilation and pulmonary hypertension resulting from a large 16 mm PDA. Percutaneous closure was successfully performed using an off-label Amplatzer muscular ventricular septal defect occluder after intravascular ultrasound assessment. Technical challenges, including accurate assessment of defect size and device selection are exemplified along with a comprehensive overview of the available literature.

  17. [Closure of pancreas stump after distal and segmental resection : Suture, stapler, coverage or anastomosis?

    PubMed

    Michalski, C W; Tramelli, P; Büchler, M W; Hackert, T

    2017-01-01

    Postoperative pancreatic fistulas represent the most frequent complication after distal and segmental pancreatectomy and occur with a frequency of up to 50 %. There are many technical variations of pancreatic stump treatment for reduction of fistula rates after distal resection. Most of these techniques have only been analyzed in retrospective studies and the evidence for or against a specific technique is low. Several retrospective trials have been conducted with good results to compare suturing with stapled closure of the remnant and to assess the effect of a vascularized falciform ligament patch in reducing postoperative pancreatic fistula; however, in a recently published randomized trial, which analyzed closure of the remnant with a pancreaticojejunostomy compared to standard closure, these results could not be confirmed. Because stapler resection and closure is the most commonly used technique in laparoscopic distal pancreatectomy, there are a large number of studies which assessed various novel methods of improving stapling. Extended stapler compression time and mesh augmentation of the stapler line can be valid methods to reduce fistula rates. Central pancreatectomy is a relatively rarely used procedure where the right-sided pancreatic remnant is closed in the same fashion as during distal pancreatectomy and the left-sided remnant is connected to the intestines with a pancreaticojejunostomy or pancreaticogastrostomy. In conclusion, postoperative pancreatic fistula rates are still a relevant clinical problem after distal pancreatectomy and further studies on potentially improved novel techniques are required.

  18. Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes.

    PubMed

    Wong, Hon-Tym; Chua, Jocelyn L L; Sakata, Lisandro M; Wong, Melissa H Y; Aung, Han T; Aung, Tin

    2009-05-01

    To evaluate the effectiveness of slitlamp optical coherence tomography (SL-OCT) and Scanning Peripheral Anterior Chamber depth analyzer (SPAC) in detecting angle closure, using gonioscopy as the reference standard. A total of 153 subjects underwent gonioscopy, SL-OCT, and SPAC. The anterior chamber angle (ACA) was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen; with SL-OCT, closure was determined by contact between the iris and angle wall anterior to the scleral spur; and with SPAC by a numerical grade of 5 or fewer and/or a categorical grade of suspect or potential. A closed ACA was identified in 51 eyes with gonioscopy, 86 eyes with SL-OCT, and 61 eyes with SPAC (gonioscopy vs SL-OCT, P < .001; gonioscopy vs SPAC, P = .10; SL-OCT vs SPAC, P < .001; McNemar test). Of the 51 eyes with a closed ACA on gonioscopy, SL-OCT detected a closed ACA in 43, whereas SPAC identified 41 (P = .79). An open angle in all 4 quadrants was observed in 102 eyes with gonioscopy, but SL-OCT and SPAC identified 43 and 20 of these eyes, respectively, as having angle closure. The overall sensitivity and specificity for SL-OCT were 84% and 58% vs 80% and 80% for SPAC. Using gonioscopy as the reference, SL-OCT and SPAC showed good sensitivity for detecting eyes at risk of angle closure.

  19. 40 CFR 265.142 - Cost estimate for closure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Section 265.142 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... salvage value that may be realized with the sale of hazardous wastes, or non-hazardous wastes if...

  20. 40 CFR 265.142 - Cost estimate for closure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Section 265.142 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... salvage value that may be realized with the sale of hazardous wastes, or non-hazardous wastes if...

  1. 40 CFR 265.142 - Cost estimate for closure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 265.142 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... salvage value that may be realized with the sale of hazardous wastes, or non-hazardous wastes if...

  2. Left ventricular dysfunction after closure of large patent ductus arteriosus.

    PubMed

    Galal, M Omar; Amin, Mohamed; Hussein, Arif; Kouatli, Amjad; Al-Ata, Jameel; Jamjoom, Ahmed

    2005-03-01

    Changes in left ventricular dimensions and performance were studied in 43 patients after transcatheter occlusion or surgical ligation of patent ductus arteriosus. The patients were assigned to 2 groups based on their ductal diameter: >/= 3.1 mm to group A (n = 27) and

  3. [Bath Plug Closure Method for Cerebrospinal Fluid Leakage by Endoscopic Endonasal Approach:Cooperative Treatment by Neurosurgeons and Otolaryngologists].

    PubMed

    Kawaguchi, Tomohiro; Arakawa, Kazuya; Nomura, Kazuhiro; Ogawa, Yoshikazu; Katori, Yukio; Tominaga, Teiji

    2017-12-01

    Endoscopic endonasal surgery, an innovative surgical technique, is used to approach sinus lesions, lesions of the skull base, and intradural tumors. The cooperation of experienced otolaryngologists and neurosurgeons is important to achieve safe and reliable surgical results. The bath plug closure method is a treatment option for patients with cerebrospinal fluid(CSF)leakage. Although it includes dural and/or intradural procedures, surgery tends to be performed by otolaryngologists because its indications, detailed maneuvers, and pitfalls are not well recognized by neurosurgeons. We reviewed the cases of patients with CSF leakage treated by using the bath plug closure method with an endoscopic endonasal approach at our institution. Three patients were treated using the bath plug closure method. CSF leakage was caused by a meningocele in two cases and trauma in one case. No postoperative intracranial complications or recurrence of CSF leakage were observed. The bath plug closure method is an effective treatment strategy and allows neurosurgeons to gain in-depth knowledge of the treatment options for CSF leakage by using an endoscopic endonasal approach.

  4. Closure of skin incisions by laser-welding with a combination of two near-infrared diode lasers: preliminary study for determination of optimal parameters

    NASA Astrophysics Data System (ADS)

    Hu, Liming; Lu, Zhihua; Wang, Biao; Cao, Junsheng; Ma, Xiaobo; Tian, Zhenhua; Gao, Zhijian; Qin, Li; Wu, Xiaodong; Liu, Yun; Wang, Lijun

    2011-03-01

    Laser welding has the potential to become an effective method for wound closure and healing without sutures. Closure of skin incisions by laser welding with a combination of two near-infrared lasers (980 and 1064 nm), was performed for the first time in this study. One centimeter long, full-thickness incisions were made on the Wistar rat's dorsal skin. The efficiencies of laser-welding with different parameters were investigated. Incision-healing, histology examination, and a tensile strength test of incisions were recorded. Laser welding with the irradiance level of 15.9 W/cm2 for both 980 and 1064-nm lasers and exposure time of 5 s per spot in continuous wave mode yielded a more effective closure and healing with minimal thermal damage, faster recovery, and stronger apposition in comparison with a suturing technique. The conclusion is that skin welding with a combination of two near-infrared diode lasers can be a good candidate for incision closure, and further investigations are in progress for clinical use.

  5. Closure of skin incisions by laser-welding with a combination of two near-infrared diode lasers: preliminary study for determination of optimal parameters.

    PubMed

    Hu, Liming; Lu, Zhihua; Wang, Biao; Cao, Junsheng; Ma, Xiaobo; Tian, Zhenhua; Gao, Zhijian; Qin, Li; Wu, Xiaodong; Liu, Yun; Wang, Lijun

    2011-03-01

    Laser welding has the potential to become an effective method for wound closure and healing without sutures. Closure of skin incisions by laser welding with a combination of two near-infrared lasers (980 and 1064 nm), was performed for the first time in this study. One centimeter long, full-thickness incisions were made on the Wistar rat's dorsal skin. The efficiencies of laser-welding with different parameters were investigated. Incision-healing, histology examination, and a tensile strength test of incisions were recorded. Laser welding with the irradiance level of 15.9 W∕cm(2) for both 980 and 1064-nm lasers and exposure time of 5 s per spot in continuous wave mode yielded a more effective closure and healing with minimal thermal damage, faster recovery, and stronger apposition in comparison with a suturing technique. The conclusion is that skin welding with a combination of two near-infrared diode lasers can be a good candidate for incision closure, and further investigations are in progress for clinical use.

  6. Fracture mechanics analyses of partial crack closure in shell structures

    NASA Astrophysics Data System (ADS)

    Zhao, Jun

    2007-12-01

    This thesis presents the theoretical and finite element analyses of crack-face closure behavior in shells and its effect on the stress intensity factor under a bending load condition. Various shell geometries, such as spherical shell, cylindrical shell containing an axial crack, cylindrical shell containing a circumferential crack and shell with double curvatures, are all studied. In addition, the influence of material orthotropy on the crack closure effect in shells is also considered. The theoretical formulation is developed based on the shallow shell theory of Delale and Erdogan, incorporating the effect of crack-face closure at the compressive edges. The line-contact assumption, simulating the crack-face closure at the compressive edges, is employed so that the contact force at the closure edges is introduced, which can be translated to the mid-plane of the shell, accompanied by an additional distributed bending moment. The unknown contact force is computed by solving a mixed-boundary value problem iteratively, that is, along the crack length, either the normal displacement of the crack face at the compressive edges is equal to zero or the contact pressure is equal to zero. It is found that due to the curvature effects crack closure may not always occur on the entire length of the crack, depending on the direction of the bending load and the geometry of the shell. The crack-face closure influences significantly the magnitude of the stress intensity factors; it increases the membrane component but decreases the bending component. The maximum stress intensity factor is reduced by the crack-face closure. The significant influence of geometry and material orthotropy on rack closure behavior in shells is also predicted based on the analytical solutions. Three-dimensional FEA is performed to validate the theoretical solutions. It demonstrates that the crack face closure occurs actually over an area, not on a line, but the theoretical solutions of the stress intensity factor and the FEA solutions are in good agreement, because the contact area is very small compared with the shell thickness.

  7. [SIMULTANEOUS MEASUREMENT OF INTRAVENTRICULAR AND PARENCHYMAL INTRACRANIAL PRESSURE IN PATIENTS WITH SEVERE TRAUMA BRAIN INJURY].

    PubMed

    Oshorov, A V; Popugaev, K A; Savin, I A; Potapov, A A

    2016-01-01

    "Standard" assessment of ICP by measuring liquor ventricular pressure recently questioned. THE OBJECTIVE OF THE STUDY: Compare the values of ventricular and parenchymal ICP against the closure of open liquor drainage and during active CSF drainage. Examined 7 patients with TBI and intracranial hypertension syndrome, GCS 5.6 ± 1.2 points, 4.2 ± age 33 years. Compared parenchymal and ventricular ICP in three time periods: 1--during closure of ventricular drainage, 2--during of the open drains and drainage at the level of 14-15 mmHg, 3--during the period of active drainage. When comparing two methods of measurement used Bland-Altman method. 1. During time period of the closed drainage correlation coefficient was r = 0.83, p < 0.001. Bland-Altman method: the difference of the two measurements is equal to the minimum and 0.7 mm Hg, the standard deviation of 2.02 mm Hg 2. During time period of the open drainage was reduction of the correlation coefficient to r = 0.46, p < 0.01. Bland-Altman method: an increase in the difference of the two measurements to -0.84 mmHg, standard deviation 2.8 mm Hg 3. During time period of the active drainage of cerebrospinal fluid was marked difference between methods of measurement. Bland-Altman method: the difference was 8.64 mm Hg, and a standard deviation of 2.6 mm Hg. 1. During the closure of the ventricular drainage were good correlation between ventricular and parenchymal ICR 2. During open the liquor drainage correlation between the two methods of measuring the intracranial pressure is reduced. 3. During the active CSF drainage correlation between the two methods of measuring intracranial pressure can be completely lost. Under these conditions, CSF pressure is not correctly reflect the ICP 4. For an accurate and continuous measurement of intracranial pressure on the background of the active CSF drainage should be carried out simultaneous parenchymal ICP measurement.

  8. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips.

    PubMed

    Gill, Amreeta; Shellock, Frank G

    2012-01-09

    Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  9. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    PubMed Central

    2012-01-01

    Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants. PMID:22230200

  10. Loop-anchor purse-string closure of gastrotomy in NOTES(R) procedures: survival studies in a porcine model.

    PubMed

    Romanelli, John R; Desilets, David J; Chapman, Christopher N; Surti, Vihar C; Lovewell, Carolanne; Earle, David B

    2010-12-01

    Transgastric NOTES(®) procedures remain without a simple method to close the gastrotomy. In four survival swine studies, we have tested a novel gastric closure device: the loop-anchor purse-string (LAPS) closure system. In four anesthetized pigs, an endoscopic gastrotomy was performed. Four loop anchors were arrayed in a 2-cm square pattern around the gastrotomy. The endoscope was passed into the abdominal cavity, and the gastrotomy was cinched closed. Procedure times ranged from 50-180 minutes. Three pigs survived 14 days. One animal was sacrificed early due to signs of sepsis. Another animal developed fevers and was treated with antibiotics. At necropsy, there were no abscesses, including in the septic animal. Histologic examination revealed evidence of healing in all animals. The LAPS system holds promise with early success in an animal model. Future human studies are needed to determine viability as a human visceral closure device.

  11. Perforated gastric ulcer--reappraisal of surgical options.

    PubMed

    Madiba, T E; Nair, R; Mulaudzi, T V; Thomson, S R

    2005-08-01

    The available operative procedures for perforated gastric ulcer are gastrectomy, ulcer excision and omental patch closure. This study analysed the outcome of these operative options in a single institution. Seventy-two patients (mean age 43 years, 62 males) with perforated gastric ulcers were managed by laparotomy. There were 34 lesser curve (incisural) and 38 antral ulcers. Partial gastrectomy was performed in 27 patients, ulcer excision in 27 and simple patch closure in 18. Two ulcers were malignant. The mortality rate was 18% (26% for gastrectomy, 19% for ulcer excision and 5% for patch closure). Shock on admission (p = 0.006) and Candida (p = 0.020) in the histological specimen were predictive of poor outcome. Hospital stay was similar in the 3 groups. Omental patch closure and ulcer excision are as effective as gastrectomy in the management of perforated gastric ulcer and merit consideration as first-line therapy in technically applicable cases.

  12. Turbulent flow computation in a circular U-Bend

    NASA Astrophysics Data System (ADS)

    Miloud, Abdelkrim; Aounallah, Mohammed; Belkadi, Mustapha; Adjlout, Lahouari; Imine, Omar; Imine, Bachir

    2014-03-01

    Turbulent flows through a circular 180° curved bend with a curvature ratio of 3.375, defined as the the bend mean radius to pipe diameter is investigated numerically for a Reynolds number of 4.45×104. The computation is performed for a U-Bend with full long pipes at the entrance and at the exit. The commercial ANSYS FLUENT is used to solve the steady Reynolds-Averaged Navier-Stokes (RANS) equations. The performances of standard k-ɛ and the second moment closure RSM models are evaluated by comparing their numerical results against experimental data and testing their capabilities to capture the formation and extend this turbulence driven vortex. It is found that the secondary flows occur in the cross-stream half-plane of such configurations and primarily induced by high anisotropy of the cross-stream turbulent normal stresses near the outer bend.

  13. Serum and Wound Vancomycin Levels After Intrawound Administration in Primary Total Joint Arthroplasty.

    PubMed

    Johnson, Jeremiah D; Nessler, Joseph M; Horazdovsky, Ryan D; Vang, Sandy; Thomas, Avis J; Marston, Scott B

    2017-03-01

    Periprosthetic joint infection is the most common cause of readmissions after total joint arthroplasty (TJA). Intrawound vancomycin powder (VP) has reduced infection rates in spine surgery; however, there are no data regarding VP in primary TJA. Thirty-four TJA patients received 2 g of VP intraoperatively to investigate VP's pharmacokinetics. Serum and wound concentrations were measured at multiple intervals over 24 hours after closure. All serum concentrations were subtherapeutic (<15μg/mL) and peaked 12 hours after closure (4.7μg/mL; standard deviation [SD], 3.2). Wound concentrations were 922 μg/mL (SD, 523) 3 hours after closure and 207 μg/mL (SD, 317) at 24 hours. VP had a half-life of 7.2 hours (95% confidence interval, 7.0-9.3) in TJA wounds. VP produced highly therapeutic intrawound concentrations while yielding low systemic levels in TJA. VP may serve as a safe adjunct in the prevention of periprosthetic joint infection. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Comparison of numerical predictions of horizontal nonisothermal jet in a room with three turbulence models -- {kappa}-{epsilon} EVM, ASM, and DSM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murakami, Shuzo; Kato, Shinsuke; Ooka, Ryozo

    1994-12-31

    A three-dimensional nonisothermal jet in a room is analyzed numerically by the standard {kappa}-{epsilon} eddy viscosity model (EVM) and two second-moment closure models-the algebraic stress model (ASM) (Hossain and Rodi 1982) and the differential stress model (DSM) (Launder et al. 1975). Numerical results given by these turbulence models are compared with experimental results, and the prediction errors existing in the results are examined, thus clarifying the relative structural differences between the {kappa}-{epsilon} EVM and the second-moment closure models. Since the second moment closure models clearly manifest the turbulence structures of the flow field, they are more accurate than the {kappa}-{epsilon}more » EVM. A small difference between the DSM and the ASM -- one based on an inappropriate approximation of the convection and diffusion terms in the Reynolds stress transport equations in the ASM -- is also observed.« less

  15. Feasibility and safety of a new generation of gore septal occluder device in children.

    PubMed

    Lombardi, Maristella; Tagliente, Maria R; Pirolo, Teodoro; Massari, Elena; Milella, Leonardo; Vairo, Ugo

    2016-12-01

    Transcatheter closure of an ostium secundum atrial septal defect (ASD) is now considered the standard care for most of children with the appropriate anatomy, and is a relatively well-tolerated procedure to reduce the clinical sequelae of ASD, with a low complication rate. The present case reports describe our clinical experience of the percutaneous closure of a secundum ASD in 10 children between December 2011 and November 2012, by means of a new generation of device, the GORE Septal Occluder device. The implantation was successful in all except two cases, the device being properly placed and deployed without malposition or embolization in the catheterization laboratory. No complications were related to the procedure. The successful implant was confirmed and no major adverse events were documented in the following 3-12 months. The new GORE Septal Occluder device appears to be a feasible, well-tolerated and successful tool for the closure of an ASD of 15 mm or less in childhood.

  16. Separating Active and Passive Influences on Stomatal Control of Transpiration[OPEN

    PubMed Central

    McAdam, Scott A.M.; Brodribb, Timothy J.

    2014-01-01

    Motivated by studies suggesting that the stomata of ferns and lycophytes do not conform to the standard active abscisic acid (ABA) -mediated stomatal control model, we examined stomatal behavior in a conifer species (Metasequoia glyptostroboides) that is phylogenetically midway between the fern and angiosperm clades. Similar to ferns, daytime stomatal closure in response to moderate water stress seemed to be a passive hydraulic process in M. glyptostroboides immediately alleviated by rehydrating excised shoots. Only after prolonged exposure to more extreme water stress did active ABA-mediated stomatal closure become important, because foliar ABA production was triggered after leaf turgor loss. The influence of foliar ABA on stomatal conductance and stomatal aperture was highly predictable and additive with the passive hydraulic influence. M. glyptostroboides thus occupies a stomatal behavior type intermediate between the passively controlled ferns and the characteristic ABA-dependent stomatal closure described in angiosperm herbs. These results highlight the importance of considering phylogeny as a major determinant of stomatal behavior. PMID:24488969

  17. Separating active and passive influences on stomatal control of transpiration.

    PubMed

    McAdam, Scott A M; Brodribb, Timothy J

    2014-04-01

    Motivated by studies suggesting that the stomata of ferns and lycophytes do not conform to the standard active abscisic acid (ABA) -mediated stomatal control model, we examined stomatal behavior in a conifer species (Metasequoia glyptostroboides) that is phylogenetically midway between the fern and angiosperm clades. Similar to ferns, daytime stomatal closure in response to moderate water stress seemed to be a passive hydraulic process in M. glyptostroboides immediately alleviated by rehydrating excised shoots. Only after prolonged exposure to more extreme water stress did active ABA-mediated stomatal closure become important, because foliar ABA production was triggered after leaf turgor loss. The influence of foliar ABA on stomatal conductance and stomatal aperture was highly predictable and additive with the passive hydraulic influence. M. glyptostroboides thus occupies a stomatal behavior type intermediate between the passively controlled ferns and the characteristic ABA-dependent stomatal closure described in angiosperm herbs. These results highlight the importance of considering phylogeny as a major determinant of stomatal behavior.

  18. High School Closures in New York City: Impacts on Students' Academic Outcomes, Attendance, and Mobility. Brief

    ERIC Educational Resources Information Center

    Kemple, James J.

    2015-01-01

    In the first decade of the 21st century, the New York City (NYC) Department of Education implemented a set of large-scale and much debated high school reforms, which included closing large, low-performing schools, opening new small schools, and extending high school choice to students throughout the district. The school closure process was the…

  19. High School Closures in New York City: Impacts on Students' Academic Outcomes, Attendance, and Mobility. Technical Appendices

    ERIC Educational Resources Information Center

    Kemple, James J.

    2015-01-01

    In the first decade of the 21st century, the New York City (NYC) Department of Education implemented a set of large-scale and much debated high school reforms, which included closing large, low-performing schools, opening new small schools, and extending high school choice to students throughout the district. The school closure process was the…

  20. High School Closures in New York City: Impacts on Students' Academic Outcomes, Attendance, and Mobility. Report

    ERIC Educational Resources Information Center

    Kemple, James J.

    2015-01-01

    In the first decade of the 21st century, the New York City (NYC) Department of Education implemented a set of large-scale and much debated high school reforms, which included closing large, low-performing schools, opening new small schools, and extending high school choice to students throughout the district. The school closure process was the…

  1. Collective Protection (COLPRO) Novel Closures Testing

    DTIC Science & Technology

    2013-03-28

    science and technology programs for future ColPro systems may include interfaces such as novel designs using zippers, hook-and-pile closures, and...necessitate new testing procedures. Additionally, stand- ards of performance must be adjusted as technologies advance. Test procedures and parameters...listed in this TOP may require updating to accommodate new technologies in test items or in test instrumentation. Any variation to the TOP procedures

  2. CORRECTIVE ACTION DECISION DOCUMENT FOR AREA 9 UXO LANDFILL, TONOPAH TEST RNGE, CAU 453, REVISION 0, MARCH 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none

    1998-03-01

    This Corrective Action Decision Document (CADD) has been prepared for the Area 9 Unexploded Ordnance (UXO) Landfill (Corrective Action Unit [CAU] 453) in accordance with the Federal Facility Agreement and Consent Order (FFACO) of 1996. Corrective Action Unit 453 is located at the Tonopah Test Range (TTR), Nevada, and is comprised of three individual landfill cells located northwest of Area 9. The cells are listed as one Corrective Action Site (CAS) 09-55-001-0952. The landfill cells have been designated as: � Cell A9-1 � Cell A9-2 � Cell A9-3 The purpose of this CADD is to identify and provide a rationalemore » for the selection of a recommended corrective action alternative for CAU 453. The scope of this CADD consists of the following tasks: � Develop corrective action objectives. � Identify corrective action alternative screening criteria. � Develop corrective action alternatives. � Perform detailed and comparative evaluations of the corrective action alternatives in relation to the corrective action objectives and screening criteria. � Recommend and justify a preferred corrective action alternative for the CAU. In June and July 1997, a corrective action investigation was performed that consisted of activities set forth in the Corrective Action Investigation Plan (CAIP) (DOE/NV, 1997). Subsurface investigation of the soils surrounding the cells revealed no contaminants of concern (COCs) above preliminary action levels. The cell contents were not investigated due to the potential for live UXO. Details concerning the analytical and investigation results can be found in Appendix A of this CADD. Based on the potential exposure pathways, the following corrective action objectives have been identified for CAU 453: � Prevent or mitigate human exposure to subsurface soils containing COCs, solid waste, and/or UXO. � Prevent adverse impacts to groundwater quality. Based on the review of existing data, future land use, and current operations at the TTR, the following alternatives have been developed for consideration at the Area 9 UXO Landfill CAU: � Alternative 1 - No Further Action � Alternative 2 - Closure in Place by Administrative Controls � Alternative 3 - Closure in Place by Capping � Alternative 4 - Clean Closure by Removal The corrective action alternatives were evaluated based on four general corrective action standards and five remedy selection decision factors. Based on the results of this evaluation, Alternative 2, Closure in Place by Administrative Controls, was selected as the preferred corrective action alternative. The preferred corrective action alternative was evaluated on its technical merits, focusing on performance, reliability, feasibility, and safety. The alternative was judged to meet all requirements for the technical components evaluated and to represent the most cost-effective corrective action. The alternative meets all applicable state and federal regulations for closure of the site and will reduce potential future exposure pathways to the contents of the landfill. During corrective action implementation, this alternative will present minimal potential threat to site workers. However, appropriate health and safety procedures will be developed and implemented.« less

  3. Streamlined Approach for Environmental Restoration Plan for Corrective Action Unit 574: Neptune, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2011-08-31

    This Streamlined Approach for Environmental Restoration (SAFER) Plan identifies the activities required for closure of Corrective Action Unit (CAU) 574, Neptune. CAU 574 is included in the Federal Facility Agreement and Consent Order (FFACO) (1996 [as amended March 2010]) and consists of the following two Corrective Action Sites (CASs) located in Area 12 of the Nevada National Security Site: (1) CAS 12-23-10, U12c.03 Crater (Neptune); (2) CAS 12-45-01, U12e.05 Crater (Blanca). This plan provides the methodology for the field activities that will be performed to gather the necessary information for closure of the two CASs. There is sufficient information andmore » process knowledge regarding the expected nature and extent of potential contaminants to recommend closure of CAU 574 using the SAFER process. Based on historical documentation, personnel interviews, site process knowledge, site visits, photographs, field screening, analytical results, the results of the data quality objective (DQO) process (Section 3.0), and an evaluation of corrective action alternatives (Appendix B), closure in place with administrative controls is the expected closure strategy for CAU 574. Additional information will be obtained by conducting a field investigation to verify and support the expected closure strategy and provide a defensible recommendation that no further corrective action is necessary. This will be presented in a Closure Report that will be prepared and submitted to the Nevada Division of Environmental Protection (NDEP) for review and approval.« less

  4. Pursestring closure of the stoma site leads to fewer wound infections: results from a multicenter randomized controlled trial.

    PubMed

    Lee, Janet T; Marquez, Thao T; Clerc, Daniel; Gie, Olivier; Demartines, Nicolas; Madoff, Robert D; Rothenberger, David A; Christoforidis, Dimitrios

    2014-11-01

    Surgical site infection after stoma reversal is common. The optimal skin closure technique after stoma reversal has been widely debated in the literature. We hypothesized that pursestring near-complete closure of the stoma site would lead to fewer surgical site infections compared with conventional primary closure. This study was a parallel prospective multicenter randomized controlled trial. This study was conducted at 2 university medical centers. Patients (N = 122) presenting for elective colostomy or ileostomy reversal were selected. Pursestring versus conventional primary closure of stoma sites were compared. Stoma site surgical site infection within 30 days of surgery, overall surgical site infection, delayed healing (open wound for >30 days), time to wound epithelialization, and patient satisfaction were the primary outcomes measured. The pursestring group had a significantly lower stoma site infection rate (2% vs 15%, p = 0.01). There was no difference in delayed healing or patient satisfaction between groups. Time to epithelialization was measured in only 51 patients but was significantly longer in the pursestring group (34.6 ± 20 days vs 24.1 ± 17 days, p = 0.02). This study was limited by the variability in procedures and surgeons, the limited follow-up after 30 days, and the inability to perform blinding. Pursestring closure after stoma reversal has a lower risk of stoma site surgical site infection than conventional primary closure, although wounds may take longer to heal with the use of this approach. NCT01713452 (www.clinicaltrials.gov).

  5. Laparoscopic repair of perforated peptic ulcer: simple closure versus omentopexy.

    PubMed

    Lin, Being-Chuan; Liao, Chien-Hung; Wang, Shang-Yu; Hwang, Tsann-Long

    2017-12-01

    This report presents our experience with laparoscopic repair performed in 118 consecutive patients diagnosed with a perforated peptic ulcer (PPU). We compared the surgical outcome of simple closure with modified Cellan-Jones omentopexy and report the safety and benefit of simple closure. From January 2010 to December 2014, 118 patients with PPU underwent laparoscopic repair with simple closure (n = 27) or omentopexy (n = 91). Charts were retrospectively reviewed for demographic characteristics and outcome. The data were compared by Fisher's exact test, Mann-Whitney U test, Pearson's chi-square test, and the Kruskal-Wallis test. The results were considered statistically significant if P < 0.05. No patients died, whereas three incurred leakage. After matching, the simple closure and omentopexy groups had similarity in sex, systolic blood pressure, pulse rate, respiratory rate, Boey score, Charlson comorbidity index, Mannheim peritonitis index, and leakage. There were statistically significant differences in age, length of hospital stay, perforated size, and operating time. Comparison of the operating time in the ≤4.0 mm and 5.0-12 mm groups revealed that the simple closure took less time than omentopexy in both groups (≤4.0 mm, 76 versus 133 minutes, P < 0.0001; 5.0-12 mm, 97 versus 139.5 minutes; P = 0.006). Compared to the omentopexy, laparoscopic simple closure is a safe procedure and shortens the operating time. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  6. 76 FR 81761 - Mine Safety Disclosure

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-28

    ... inspections pursuant to miners' complaints.\\18\\ If violations of safety or health standards are found, MSHA... appropriateness of proposed penalties. Other types of cases include miners' complaints of safety- or health-related discrimination and miners' applications for compensation after a mine has been idled by a closure...

  7. 78 FR 2284 - Methodology for Selecting Job Corps Centers for Closure; Comments Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-10

    ... (GED), and career technical training credentials, including industry-recognized credentials, state... align existing career technical training programs to technical standards established by industries or... technical training. Both PIPs and CAPs are used for continued monitoring and implemented for USDA and...

  8. 49 CFR 178.518 - Standards for woven plastic bags.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... plastic bag; (2) 5H2 for a sift-proof woven plastic bag; and (3) 5H3 for a water-resistant woven plastic... other equally strong method of closure. (3) Bags, sift-proof, 5H2 must be made sift-proof by appropriate...

  9. 40 CFR 264.142 - Cost estimate for closure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 264.142 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES... may be realized with the sale of hazardous wastes, or non-hazardous wastes if applicable under § 264...

  10. 40 CFR 264.142 - Cost estimate for closure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 264.142 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES... may be realized with the sale of hazardous wastes, or non-hazardous wastes if applicable under § 264...

  11. 40 CFR 264.142 - Cost estimate for closure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Section 264.142 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES... may be realized with the sale of hazardous wastes, or non-hazardous wastes if applicable under § 264...

  12. 40 CFR 264.142 - Cost estimate for closure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Section 264.142 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES... may be realized with the sale of hazardous wastes, or non-hazardous wastes if applicable under § 264...

  13. Minimally Invasive Posterior Hamstring Harvest

    PubMed Central

    Wilson, Trent J.; Lubowitz, James H.

    2013-01-01

    Autogenous hamstring harvesting for knee ligament reconstruction is a well-established standard. Minimally invasive posterior hamstring harvest is a simple, efficient, reproducible technique for harvest of the semitendinosus or gracilis tendon or both medial hamstring tendons. A 2- to 3-cm longitudinal incision from the popliteal crease proximally, in line with the semitendinosus tendon, is sufficient. The deep fascia is bluntly penetrated, and the tendon or tendons are identified. Adhesions are dissected. Then, an open tendon stripper is used to release the tendon or tendons proximally; a closed, sharp tendon stripper is used to release the tendon or tendons from the pes. Layered, absorbable skin closure is performed, and the skin is covered with a skin sealant, bolster dressing, and plastic adhesive bandage for 2 weeks. PMID:24266003

  14. Clinical Trial Principles and Endpoint Definitions for Paravalvular Leaks in Surgical Prosthesis: An Expert Statement.

    PubMed

    Ruiz, Carlos E; Hahn, Rebecca T; Berrebi, Alain; Borer, Jeffrey S; Cutlip, Donald E; Fontana, Greg; Gerosa, Gino; Ibrahim, Reda; Jelnin, Vladimir; Jilaihawi, Hasan; Jolicoeur, E Marc; Kliger, Chad; Kronzon, Itzhak; Leipsic, Jonathon; Maisano, Francesco; Millan, Xavier; Nataf, Patrick; O'Gara, Patrick T; Pibarot, Philippe; Ramee, Stephen R; Rihal, Charanjit S; Rodes-Cabau, Josep; Sorajja, Paul; Suri, Rakesh; Swain, Julie A; Turi, Zoltan G; Tuzcu, E Murat; Weissman, Neil J; Zamorano, Jose L; Serruys, Patrick W; Leon, Martin B

    2017-04-25

    The VARC (Valve Academic Research Consortium) for transcatheter aortic valve replacement set the standard for selecting appropriate clinical endpoints reflecting safety and effectiveness of transcatheter devices, and defining single and composite clinical endpoints for clinical trials. No such standardization exists for circumferentially sutured surgical valve paravalvular leak (PVL) closure. This document seeks to provide core principles, appropriate clinical endpoints, and endpoint definitions to be used in clinical trials of PVL closure devices. The PVL Academic Research Consortium met to review evidence and make recommendations for assessment of disease severity, data collection, and updated endpoint definitions. A 5-class grading scheme to evaluate PVL was developed in concordance with VARC recommendations. Unresolved issues in the field are outlined. The current PVL Academic Research Consortium provides recommendations for assessment of disease severity, data collection, and endpoint definitions. Future research in the field is warranted. Copyright © 2017 American College of Cardiology Foundation and European Society of Cardiology. Published by Elsevier Inc. All rights reserved.

  15. Immediate tight sealing of skin incisions using an innovative temperature-controlled laser soldering device: in vivo study in porcine skin.

    PubMed

    Simhon, David; Halpern, Marisa; Brosh, Tamar; Vasilyev, Tamar; Ravid, Avi; Tennenbaum, Tamar; Nevo, Zvi; Katzir, Abraham

    2007-02-01

    A feedback temperature-controlled laser soldering system (TCLS) was used for bonding skin incisions on the backs of pigs. The study was aimed: 1) to characterize the optimal soldering parameters, and 2) to compare the immediate and long-term wound healing outcomes with other wound closure modalities. A TCLS was used to bond the approximated wound margins of skin incisions on porcine backs. The reparative outcomes were evaluated macroscopically, microscopically, and immunohistochemically. The optimal soldering temperature was found to be 65 degrees C and the operating time was significantly shorter than with suturing. The immediate tight sealing of the wound by the TCLS contributed to rapid, high quality wound healing in comparison to Dermabond or Histoacryl cyanoacrylate glues or standard suturing. TCLS of incisions in porcine skin has numerous advantages, including rapid procedure and high quality reparative outcomes, over the common standard wound closure procedures. Further studies with a variety of skin lesions are needed before advocating this technique for clinical use.

  16. Safety of low dose heparin in elective coronary angioplasty.

    PubMed Central

    Koch, K. T.; Piek, J. J.; de Winter, R. J.; David, G. K.; Mulder, K.; Tijssen, J. G.; Lie, K. I.

    1997-01-01

    OBJECTIVES: To evaluate the safety of a low dose of heparin in consecutive stable patients undergoing elective percutaneous transluminal coronary angioplasty (PTCA). DESIGN: Open prospective study in a single centre. PATIENTS: 1375 consecutive patients had elective PTCA (1952 lesions: type A 11%, B1 34%, B2 36%, and C 19%). There were no angiographic exclusion criteria. INTERVENTIONS: A bolus of 5000 IU heparin was used as the standard anticoagulation regimen during PTCA. The sheaths were removed immediately after successful completion of the procedure. Prolongation of heparin treatment was left to the operator's discretion. MAIN OUTCOME MEASURES: Procedural success was defined as < 50% residual stenosis without death from any cause, acute myocardial infarction, urgent coronary bypass surgery, or repeat angioplasty within 48 hours for acute recurrent ischaemia; the need for prolonged heparinisation; and the occurrence of puncture site complications. RESULTS: Procedural success without clinical events was achieved in 90% of patients. Mortality was 0.3%; coronary bypass surgery was performed in 1.7% of the procedures. The rate of myocardial infarction was 3.3%; repeat angioplasty within 48 hours was carried out in 0.7% of patients. A total of 89.1% of the patients were treated according to the protocol. Prolonged treatment with heparin was considered necessary in 123 patients (8.9%). Repeat angioplasty for abrupt closure was performed in two patients shortly after sheath removal and in two during prolonged heparinisation. Puncture site complications occurred in 2.1% of patients (low dose heparin 1.9% and prolonged heparinisation 4.9%). CONCLUSION: Elective PTCA can be safely performed using a low dose of heparin, with a negligible risk for subacute closure. Low dose heparin may reduce the incidence of puncture site complications, shorten hospitalisation, and enable out-patient angioplasty. PMID:9227294

  17. Probabilistic density function method for nonlinear dynamical systems driven by colored noise.

    PubMed

    Barajas-Solano, David A; Tartakovsky, Alexandre M

    2016-05-01

    We present a probability density function (PDF) method for a system of nonlinear stochastic ordinary differential equations driven by colored noise. The method provides an integrodifferential equation for the temporal evolution of the joint PDF of the system's state, which we close by means of a modified large-eddy-diffusivity (LED) closure. In contrast to the classical LED closure, the proposed closure accounts for advective transport of the PDF in the approximate temporal deconvolution of the integrodifferential equation. In addition, we introduce the generalized local linearization approximation for deriving a computable PDF equation in the form of a second-order partial differential equation. We demonstrate that the proposed closure and localization accurately describe the dynamics of the PDF in phase space for systems driven by noise with arbitrary autocorrelation time. We apply the proposed PDF method to analyze a set of Kramers equations driven by exponentially autocorrelated Gaussian colored noise to study nonlinear oscillators and the dynamics and stability of a power grid. Numerical experiments show the PDF method is accurate when the noise autocorrelation time is either much shorter or longer than the system's relaxation time, while the accuracy decreases as the ratio of the two timescales approaches unity. Similarly, the PDF method accuracy decreases with increasing standard deviation of the noise.

  18. EWOLUTION: Design of a registry to evaluate real-world clinical outcomes in patients with AF and high stroke risk-treated with the WATCHMAN left atrial appendage closure technology.

    PubMed

    Boersma, Lucas V A; Schmidt, Boris; Betts, Tim R; Sievert, Horst; Tamburino, Corrado; Teiger, Emmanuel; Stein, Kenneth M; Bergmann, Martin W

    2016-09-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and the rate of ischemic stroke attributed to non-valvular AF is estimated at 5% per year. Several multi-center studies established left atrial appendage closure as a safe and effective alternative to oral anticoagulation, but there is a need for additional real world data. The purpose of this observational, prospective, single-arm, multicenter clinical study is to compile real-world clinical outcome data for WATCHMAN™ LAA (left atrial appendage) Closure Technology. One thousand subjects at up to 70 institutions in Europe, the Middle East, and Russia will be enrolled. Patients will be followed for 2 years after WATCHMAN implantation, according to standard medical practice. Primary endpoints include procedural and long-term data including stroke/embolism, bleeding, and death. This article presents the background of the LAAC device and describes the design of the study. Results for peri-procedural analyses are expected toward the end of 2015; long-term follow-up data are expected in the latter half of 2017. The EWOLUTION study will formally expand knowledge of LAA closure into a broader real world setting. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  19. Secondary closure of alveolar cleft with resorbable collagen membrane and a combination of intraoral autogenous bone graft and deproteinized anorganic bovine bone

    PubMed Central

    Aly, Lobna Abdel Aziz; Hammouda, Nelly

    2016-01-01

    Objects: Secondary alveolar bone grafting is a method that enables an excellent oral rehabilitation of the patients having alveolar cleft. The aim of this work is to report the closure of the alveolar cleft with the use of harvested autogenous bone graft combined with deproteinized anorganic bovine bone (Bio-Oss) under local anesthesia. Settings and Sample Population: Nine patients with age range, 8–11 years were consulted for their unilateral alveolar cleft. Materials and Methods: A combination of symphyseal bone and deproteinized bovine bone mineral (DBBM) was placed into the alveolar cleft defect. Clinical and radiographical assessments were performed at 1, 3, and 6 months postoperatively. Results: The healing period was uneventful in all cases, and no complications, such as membrane exposure, infection, or harvest site morbidity, were observed. All treated defect sites exhibited excellent bone formation, with an average of 5.45 mm (range, 2–9 mm; standard deviation 1.93 mm) of augmentation achieved overall. Conclusion: The treatment of vertically deficient alveolar ridges with guided bone regeneration using a mixture of autogenous bone and DBBM and resorbable collagen membrane can be considered successful, using this technique in an out-patient office setting. PMID:28299252

  20. New method for maximum mobilization of temporalis muscle flap.

    PubMed

    Masic, Tarik; Babajic, Emina; Dervisevic, Almir; Hassouba, Mahmoud

    2012-01-01

    Pedicled temporalis muscle flap presenting a good flap for closing large craniofacial defects. Careful surgeons usually do not mobilize temporalis muscle flap enough to make appropriate use, fully closure, especially if defect exceeds the median line. Temporalis flap was used in 16 patients, ages ranged between 12 and 76. In all cases defect reconstruction was done by useing new method of extending standard temporal muscle flap. During surgical procedure it is very important to keep periosteal elevator in close contact with the bone. Then, there is no risk for pedicle injury. After vascular pedicle is identified elevating temporal muscle has to be continued by releasing the muscle insertion from the coronoid process. By this way, flap length and arc of rotation is increased. The flap remained viable in all instances. Most of the patients experienced no perioperative complications. There was no major complications or mortality as a result of performed procedures. With this division, flap length was increased at least 2 cm wich is enough for covering defects crossing the midline. Instead of using bilateral temporalis muscle flaps for defect closure, unilateral is sufficient. With this extension of the pedicle length now rotation point is not at the level of the zygomatic arch but lower part mandibular neck.

  1. Transition and closeout of the Fernald Closure Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bilson, H.E.; Terry, T.; Reising, J.

    The U.S. Department of Energy (DOE) and Fluor Fernald have completed the majority of the cleanup of the Fernald Site. The over 1,000 acre complex for processing uranium has been demolished and soil contamination has been remediated. With acres of wetlands and prairies replacing the buildings and waste pits. At the end of the project the focus shifted to developing demonstrating the completion of the project and the contract, as well as ensuring a smooth transition of the facility from the DOE's Environmental Management (EM) Program to the DOE's Legacy Management (LM) Program. Working with the DOE, each portion ofmore » the closure contract was examined for specific closure definition. From this negotiation effort the Comprehensive Exit and Transition Plan (CE/T Plan) was written. The CE/T Plan is intended to assist DOE in the analysis that the site is ready for transfer into long-term stewardship (LTS) (also referred to as legacy management) and that Fluor Fernald, Inc. has satisfactorily completed the closure contract statement of work elements. Following the Lessons Learned from the closure of the Rocky Flats Site, the DOE's Legacy Management Program created a matrix of Transition Elements required to ensure adequate information was in place to allow the new prime contractor to perform the Legacy Management scope of work. The transition plan included over 1,000 elements broken down into functional areas and relied on specific Fernald Responsibility Transition Packages (RTPs) for detailed transition actions. The template for Closure and Transition Planning used at the Fernald Site was developed using the best Lessons Learned from across the DOE Complex. The template could be used for other sites, and lessons learned from this closure and transition will be appropriate for all closure projects. (authors)« less

  2. Coincidental Impact of Transcatheter Patent Foramen Ovale Closure on Migraine with and without Aura - A Comprehensive Meta-Analysis.

    PubMed

    Kanwar, Siddak M; Noheria, Amit; DeSimone, Christopher V; Rabinstein, Alejandro A; Asirvatham, Samuel J

    2016-03-01

    We analyzed the literature to assess the coincidental impact on migraines of transcatheter patent foramen ovale (PFO) closure performed for secondary stroke prevention. We searched Medline, EMBASE, and the Cochrane database for studies published up until August 2013. We included English-language studies that provided information on complete resolution or improvement in migraine headaches following PFO closure. Two study authors identified 375 original articles and both independently reviewed 32 relevant manuscripts. Data including study methodology, inclusion criteria, PFO closure and migraine outcomes were extracted manually from all eligible studies. Pooled odds (and probability) of resolution or improvement of migraine headaches were calculated using random-effects models. Twenty studies were analyzed. Most were uncontrolled studies that included a small number of patients with cryptogenic stroke who had undergone PFO closure and had variable time of followup. The probability of complete resolution of migraine with PFO closure (18 studies, 917 patients) was 0.46 (95% confidence interval 0.39, 0.53) and of any improvement in migraine (17 studies, 881 patients) was 0.78 (0.74, 0.82). There was evidence for publication bias in studies reporting on improvement in migraines (Begg's p=0.002), but not for studies on complete resolution of migraine (p=0.3). In patients with aura, the probability of complete resolution of migraine post-PFO closure was 0.54 (0.43, 0.65), and in those without aura, complete resolution occurred in 0.39 (0.29, 0.51). Among patients with unexplained stroke and migraine undergoing transcatheter PFO closure, resolution of headaches occurred in a majority of patients with aura and for a smaller proportion of patients without aura.

  3. Prospective experimental study of transrectal viscerotomy closure using transanal endoscopic suture vs. circular stapler: a step toward NOTES.

    PubMed

    Diana, M; Leroy, J; Wall, J; De Ruijter, V; Lindner, V; Dhumane, P; Mutter, D; Marescaux, J

    2012-06-01

    Endoluminal full-thickness closure of the rectal wall is critical in emerging procedures including endoscopic submucosal dissection and transrectal natural orifice transluminal endoscopic surgery (NOTES). This study aimed to compare manual suture using the transanal endoscopic operation platform (TEO; Karl Storz, Tüttlingen, Germany) with the end-to-end anastomosis hemorrhoid circular stapler (EEA; Covidien, Dublin, Ireland) for closure of the rectal viscerotomy during transrectal NOTES segmental colectomy. A total of 12 swine underwent transrectal hybrid NOTES partial colectomies. Animals were divided into two groups according to the viscerotomy closure technique: 1) TEO manual suture; 2) EEA circular stapler closure. Mean (± SD) viscerotomy closure time was 67.5 ± 59.5 minutes and 31.5 ± 19.6 minutes for TEO and EEA, respectively. There was one conversion to laparoscopy in the TEO group and a misfiring in the EEA group that required a TEO salvage suture. There was one positive air-leak test in each group. Peritoneal fluid collected at the end of the procedure tested positive for bacterial contamination in all cases. A mild stenosis was present in 4 /6 viscerotomies (67 %) in the TEO group and in 1/6 (17 %) in the EEA group on endoscopic control. Inflammatory changes were mild in 3/5 (60 %) and 4/5 (80 %) viscerotomies in the TEO and EEA groups, respectively, whereas severe inflammation was found in 2/5 (TEO) and 1 /5 (EEA). Transrectal viscerotomy closure using the EEA circular stapler technique is feasible, easy to perform, and histologically comparable to suture closure through a TEO platform. It may offer an attractive alternative for NOTES segmental colectomies and endoscopic resections. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography.

    PubMed

    Tay, Elton Lik Tong; Yong, Vernon Khet Yau; Lim, Boon Ang; Sia, Stelson; Wong, Elizabeth Poh Ying; Yip, Leonard Wei Leon

    2015-01-01

    To determine angle closure agreements between gonioscopy and anterior segment optical coherence tomography (AS-OCT), as well as gonioscopy and spectral domain OCT (SD-OCT). A secondary objective was to quantify inter-observer agreements of AS-OCT and SD-OCT assessments. Seventeen consecutive subjects (33 eyes) were recruited from the study hospital's Glaucoma clinic. Gonioscopy was performed by a glaucomatologist masked to OCT results. OCT images were read independently by 2 other glaucomatologists masked to gonioscopy findings as well as each other's analyses of OCT images. Totally 84.8% and 45.5% of scleral spurs were visualized in AS-OCT and SD-OCT images respectively (P<0.01). The agreement for angle closure between AS-OCT and gonioscopy was fair at k=0.31 (95% confidence interval, CI: 0.03-0.59) and k=0.35 (95% CI: 0.07-0.63) for reader 1 and 2 respectively. The agreement for angle closure between SD-OCT and gonioscopy was fair at k=0.21 (95% CI: 0.07-0.49) and slight at k=0.17 (95% CI: 0.08-0.42) for reader 1 and 2 respectively. The inter-reader agreement for angle closure in AS-OCT images was moderate at 0.51 (95% CI: 0.13-0.88). The inter-reader agreement for angle closure in SD-OCT images was slight at 0.18 (95% CI: 0.08-0.45). Significant proportion of scleral spurs were not visualised with SD-OCT imaging resulting in weaker inter-reader agreements. Identifying other angle landmarks in SD-OCT images will allow more consistent angle closure assessments. Gonioscopy and OCT imaging do not always agree in angle closure assessments but have their own advantages, and should be used together and not exclusively.

  5. Closure of tubular patent ductus arteriosus with the Amplatzer Vascular Plug IV: feasibility and safety.

    PubMed

    Baruteau, Alban-Elouen; Lambert, Virginie; Riou, Jean-Yves; Angel, Claude-Yves; Belli, Emre; Petit, Jérôme

    2015-01-01

    Closure of tubular patent ductus arteriosus remains a challenging procedure. Anecdotal use of Amplatzer Vascular Plug IV for tubular ductus closure has been reported but feasibility and safety in a consecutive patients' series remain unknown. We performed a monocenter prospective study at the Marie Lannelongue Hospital in Paris, France. From 2009 to 2014, a total of 47 patients (39 infants, 3 children, and 5 adults) underwent ductus closure with the Plug IV. Ductus morphology was a type E in 34 (72.3%) patients and a type C in 13 (27.7%) patients. Ductus closure occurred in 39 (83.0%) infants at a median age of seven months (range: 3-23 months) and a median weight of 6.9 kg (range: 4.1-17.0 kg). A past history of prematurity and very low birth weight was found in 33 (70.2%) of them. Twelve (25.5%) patients had pulmonary hypertension. Mean Plug IV diameter was 1.9 ± 0.1 mm larger than the mean maximal ductus diameter. Early complete closure of the ductus was obtained in all patients. Early migration of an undersized Plug IV occurred in one (2.1%) patient and was suitable for percutaneous device retrieval. After a mean follow-up of 3.4 ± 1.4 years, all patients are alive and asymptomatic, no late complication occurred. Transcatheter closure of tubular ductus with the Amplatzer Vascular Plug IV can be safe and effective, with a 100% early occlusion rate. This device, suitable for a 4F sheath, is a new alternative for tubular ductus closure in low-body-weight infants. © The Author(s) 2014.

  6. Variation in practice patterns in device closure of atrial septal defects and patent ductus arteriosus: An analysis of data from the IMproving Pediatric and Adult Congenital Treatment (IMPACT) registry.

    PubMed

    O'Byrne, Michael L; Kennedy, Kevin F; Rome, Jonathan J; Glatz, Andrew C

    2018-02-01

    Practice variation is a potentially important measure of healthcare quality. The IMPACT registry provides a representative national sample with which to study practice variation in trans-catheter interventions for congenital heart disease. We studied cases for closure of atrial septal defect (ASD) and patent ductus arteriosus (PDA) in IMPACT between January 1, 2011, and September 30, 2015, using hierarchical multivariate models studying (1) the distribution of indications for closure and (2) in patients whose indication for closure was left (LVVO) or right ventricular volume overload (RVVO), the factors influencing probability of closure of a small defect (either in size or in terms of the magnitude of shunt). Over the study period, 5233 PDA and 4459 ASD cases were performed at 77 hospitals. The indications for ASD closure were RVVO in 84% and stroke prevention in 13%. Indications for PDA closure were LVVO in 57%, endocarditis prevention in 36%, and pulmonary hypertension in 7%. There was statistically significant variability in indications between hospitals for PDA and ASD procedures (median rate ratio (MRR): 1.3 and 1.1; both P<.001). The proportion of cases for volume overload with a Qp:Qs <1.5:1 decreased with increasing PDA and ASD procedural volume (P=.04 and 0.05). For ASD, the proportion was higher at hospitals with a larger proportion of adult cases (P=.0007). There was significant variation in practice in the risk of closing PDA <2 mm for LVVO (MRR: 1.4, P<.001). There is measurable variation in transcatheter closure of PDA and ASD. Further research is necessary to study whether this affects outcomes or resource utilization. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Auditory skills of figure-ground and closure in air traffic controllers.

    PubMed

    Villar, Anna Carolina Nascimento Waack Braga; Pereira, Liliane Desgualdo

    2017-12-04

    To investigate the auditory skills of closure and figure-ground and factors associated with health, communication, and attention in air traffic controllers, and compare these variables with those of other civil and military servants. Study participants were sixty adults with normal audiometric thresholds divided into two groups matched for age and gender: study group (SG), comprising 30 air traffic controllers and control group (CG), composed of 30 other military and civil servants. All participants were asked a number of questions regarding their health, communication, and attention, and underwent the Speech-in-Noise Test (SIN) to assess their closure skills and the Synthetic Sentence Identification Test - Ipsilateral Competitive Message (SSI-ICM) in monotic listening to evaluate their figure-ground abilities. Data were compared using nonparametric statistical tests and logistic regression analysis. More individuals in the SG reported fatigue and/or burnout and work-related stress and showed better performance than that of individuals in the CG for the figure-ground ability. Both groups performed similarly and satisfactorily in the other hearing tests. The odds ratio for participants belonging in the SG was 5.59 and 1.24 times regarding work-related stress and SSI-ICM (right ear), respectively. Results for the variables auditory closure, self-reported health, attention, and communication were similar in both groups. The SG presented significantly better performance in auditory figure-ground compared with that of the CG. Self-reported stress and right-ear SSI-ICM were significant predictors of individuals belonging to the SG.

  8. TANK FARM CLOSURE - A NEW TWIST ON REGULATORY STRATEGIES FOR CLOSURE OF WASTE TANK RESIDUALS FOLLOWING NUREG

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LEHMAN LL

    2008-01-23

    Waste from a number of single-shell tanks (SST) at the U.S. Department of Energy's (DOE) Hanford Site has been retrieved by CH2M HILL Hanford Group to fulfill the requirements of the 'Hanford Federal Facility Agreement and Consent Order (HFFACO) [1]. Laboratory analyses of the Hanford tank residual wastes have provided concentration data which will be used to determine waste classification and disposal options for tank residuals. The closure of tank farm facilities remains one of the most challenging activities faced by the DOE. This is due in part to the complicated regulatory structures that have developed. These regulatory structures aremore » different at each of the DOE sites, making it difficult to apply lessons learned from one site to the next. During the past two years with the passage of the Section 3116 of the 'Ronald Reagan Defense Authorization Act of 2005' (NDAA) [2] some standardization has emerged for Savannah River Site and the Idaho National Laboratory tank residuals. Recently, with the issuance of 'NRC Staff Guidance for Activities Related to US. Department of Energy Waste Determinations' (NUREG-1854) [3] more explicit options may be considered for Hanford tank residuals than are presently available under DOE Orders. NUREG-1854, issued in August 2007, contains several key pieces of information that if utilized by the DOE in the tank closure process, could simplify waste classification and streamline the NRC review process by providing information to the NRC in their preferred format. Other provisions of this NUREG allow different methods to be applied in determining when waste retrieval is complete by incorporating actual project costs and health risks into the calculation of 'technically and economically practical'. Additionally, the NUREG requires a strong understanding of the uncertainties of the analyses, which given the desire of some NRC/DOE staff may increase the likelihood of using probabilistic approaches to uncertainty analysis. The purpose of this paper is to discuss implications of NUREG-1854 and to examine the feasibility and potential benefits of applying these provisions to waste determinations and supporting documents such as future performance assessments for tank residuals.« less

  9. Modified Design of Anterolateral Thigh Flap for Total Pharyngolaryngectomy Reconstruction: A Single-Center Experience.

    PubMed

    Cheng, Li-Yen; Chen, Cha-Chun; Lin, Hwang-Chi; Jeng, Chu-Hsu; Lin, Shang-Hsi; Chen, Wei-Nung Jim; Lin, Yu-Hsien; Hao, Sheng-Po

    2018-07-01

    Defects after total pharyngolaryngectomy for hypopharyngeal cancer often require reconstruction via free tissue transfer. Recently, anterolateral thigh (ALT) flap has become the gold standard in many centers because of its advantages with respect to versatility, minimal donor-site morbidity, good speech quality, and relatively low fistula and anastomotic leakage rates. Moreover, ALT allows 2 surgical teams to work simultaneously. However, the height of the parallelogram in the ALT design for neoesophagus reconstruction is usually set at a minimum of 9.4 cm (circumference, 2πr) for smooth food passage. Because this height exceeds 8 cm, the donor site may not be closed primarily, which highly depends on the patient's body habitus and the skin tone or quality and requires other methods, such as local flap or skin graft for wound closure, which subsequently increase operating time and donor-site complication rate. Thus, we aimed to construct a simple and modified ALT design that will not only include the advantages described earlier but also provide adequate donor-site primary closure without jeopardizing complication rates. Ten patients with hypopharyngeal cancer underwent reconstructive surgery using our modified ALT design after total pharyngolaryngectomy between 2010 and 2017. Our modified ALT design converts this "classical" shape into a parallelogram so that the height of the modified design is always less than 8 cm, thus allowing for easy primary closure of the wound. The donor-site defects of all 10 patients were closed primarily. No donor-site complications and partial or total flap loss were observed. One patient experienced persistent wound infection with dehiscence, for which debridement was performed. The stricture and fistula rates were 10% (n = 1) and 20% (n = 2), respectively. The mean follow-up time is approximately 1 year. Minimizing donor-site morbidity is an important goal in reconstructive surgery. Our modified ALT flap design is simple, enabling easy primary closure of the donor-site defect, with improved results for the patient and operators. Furthermore, this design is also suitable for ALT flaps with widths larger than 8 cm.

  10. Primary closure after carotid endarterectomy is not inferior to other closure techniques.

    PubMed

    Avgerinos, Efthymios D; Chaer, Rabih A; Naddaf, Abdallah; El-Shazly, Omar M; Marone, Luke; Makaroun, Michel S

    2016-09-01

    Primary closure after carotid endarterectomy (CEA) has been much maligned as an inferior technique with worse outcomes than in patch closure. Our purpose was to compare perioperative and long-term results of different CEA closure techniques in a large institutional experience. A consecutive cohort of CEAs between January 1, 2000, and December 31, 2010, was retrospectively analyzed. Closure technique was used to divide patients into three groups: primary longitudinal arteriotomy closure (PRC), patch closure (PAC), and eversion closure (EVC). End points were perioperative events, long-term strokes, and restenosis ≥70%. Multivariate regression models were used to assess the effect of baseline predictors. There were 1737 CEA cases (bilateral, 143; mean age, 71.4 ± 9.3 years; 56.2% men; 35.3% symptomatic) performed during the study period with a mean clinical follow-up of 49.8 ± 36.4 months (range, 0-155 months). More men had primary closure, but other demographic and baseline symptoms were similar between groups. Half the patients had PAC, with the rest evenly distributed between PRC and EVC. The rate of nerve injury was 2.7%, the rate of reintervention for hematoma was 1.5%, and the length of hospital stay was 2.4 ± 3.0 days, with no significant differences among groups. The combined stroke and death rate was 2.5% overall and 3.9% and 1.7% in the symptomatic and asymptomatic cohort, respectively. Stroke and death rates were similar between groups: PRC, 11 (2.7%); PAC, 19 (2.2%); EVC, 13 (2.9%). Multivariate analysis showed baseline symptomatic disease (odds ratio, 2.4; P = .007) and heart failure (odds ratio, 3.1; P = .003) as predictors of perioperative stroke and death, but not the type of closure. Cox regression analysis demonstrated, among other risk factors, no statin use (hazard ratio, 2.1; P = .008) as a predictor of ipsilateral stroke and severe (glomerular filtration rate <30 mL/min/1.73 m(2)) renal insufficiency (hazard ratio, 2.6; P = .032) as the only predictor of restenosis ≥70%. Type of closure did not have any predictive value. In our study, baseline risk factors and statin use, but not the type of closure, affect perioperative and long-term outcomes after CEA. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  11. Final closure of a low level waste disposal facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potier, J.M.

    1995-12-31

    The low-level radioactive waste disposal facility operated by the Agence Nationale pour la Gestion des Dechets Radioactifs near La Hague, France was opened in 1969 and is scheduled for final closure in 1996. The last waste package was received in June 1994. The total volume of disposed waste is approximately 525,000 m{sup 3}. The site closure consists of covering the disposal structures with a multi-layer impervious cap system to prevent rainwater from infiltrating the waste isolation system. A monitoring system has been set up to verify the compliance of infiltration rates with hydraulic performance objectives (less than 10 liters permore » square meter and per year).« less

  12. BetaScint{trademark} fiber-optic sensor for detecting strontium-90 and uranium-238 in soil. Innovative technology summary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-01

    Accurate measurements of radioactivity in soils contaminated with Strontium-90 (Sr-90) or Uranium-238 (U-238) are essential for many DOE site remediation programs. These crucial measurements determine if excavation and soil removal is necessary, where remediation efforts should be focused, and/or if a site has reached closure. Measuring soil contamination by standard EPA laboratory methods typically takes a week (accelerated analytical test turnaround) or a month (standard analytical test turnaround). The time delay extends to operations involving heavy excavation equipment and associated personnel which are the main costs of remediation. This report describes an application of the BetaScint{trademark} fiber-optic sensor that measuresmore » Sr-90 or U-238 contamination in soil samples on site in about 20 minutes, at a much lower cost than time-consuming laboratory methods, to greatly facilitate remediation. This report describes the technology, its performance, its uses, cost, regulatory and policy issues, and lessons learned.« less

  13. Planned secondary wound closure at the circular stapler insertion site after laparoscopic gastric bypass reduces postoperative morbidity, costs, and hospital stay.

    PubMed

    Vetter, Diana; Raptis, Dimitri Aristotle; Giama, Mira; Hosa, Hanna; Muller, Markus K; Nocito, Antonio; Schiesser, Marc; Moos, Rudolf; Bueter, Marco

    2017-12-01

    The aims of the present study were to assess whether planned secondary wound closure at the insertion site of the circular stapler reduces wound infection rate and postoperative morbidity after laparoscopic Roux-en-Y gastric bypass (RYGB) and to identify independent predictive factors increasing the risk for wound infections after RYGB. This paper is a retrospective single-center analysis of a prospectively collected database of 1400 patients undergoing RYGB surgery in circular technique between June 2000 and June 2016. Planned secondary wound closure at the circular stapler introduction site was performed at postoperative day 3 in 291 (20.8%) consecutive patients and compared to a historical control of 1109 (79.2%) consecutive patients with primary wound closure. Independent predictive factors for wound infection were assessed by multivariable analysis. Secondary wound closure significantly decreased wound infection rate from 9.3% (103/1109) to 1% (3/291) (p < 0.001) leading to a shorter hospital stay (mean 9 (SD8) vs. 7 days (SD2), p < 0.001), lower costs (p = 0.039), and reduced postoperative morbidity (mean 90-day Comprehensive Complication Index (CCI) 7.4 (SD14.0) vs. 5.1 (SD11.1) p = 0.008) when compared to primary wound closure. Primary wound closure, dyslipidemia, and preoperative gastritis were independent predictive risk factors for developing wound infections both in the univariate (p < 0.001; p = 0.048; p = 0.003) and multivariable analysis (p < 0.001; p = 0.040; p = 0.012). Further, on multivariable analysis, the female gender was a predictive factor (p = 0.034) for wound infection development. Secondary wound closure at the circular stapler introduction site in laparoscopic RYGB significantly reduces the overall wound infection rate as well as postoperative morbidity, costs, and hospital stay when compared to primary wound closure.

  14. Long-term outcomes of patent foramen ovale closure or medical therapy after cryptogenic stroke: A meta-analysis of randomized trials.

    PubMed

    Abdelaziz, Hesham K; Saad, Marwan; Abuomara, Hossamaldin Z; Nairooz, Ramez; Pothineni, Naga Venkata K; Madmani, Mohamed E; Roberts, David H; Mahmud, Ehtisham

    2018-05-04

    To examine long-term clinical outcomes with transcatheter patent foramen ovale (PFO) closure versus medical therapy alone in patients with cryptogenic stroke. A long-standing debate regarding the optimal approach for the management of patients with PFO after a cryptogenic stroke exists. An electronic search was performed for randomized clinical trials (RCTs) reporting clinical outcomes with PFO closure vs. medical therapy alone after stroke. Random effects DerSimonian-Laird risk ratios (RR) were calculated. The main outcome was recurrence of stroke. Other outcomes included transient ischemic attack (TIA), new-onset atrial fibrillation/flutter (AF/AFL), major bleeding, serious adverse events, and device-related complications. All-cause mortality was also examined. Five RCTs with a total of 3,440 patients were included. At a mean follow-up of 4.02 ± 1.57 years, PFO closure was associated with less recurrence of stroke (RR = 0.43; 95% CI 0.19-0.91; P = .027) compared with medical therapy alone. No difference was observed between both strategies for TIA (P = .21), major bleeding (P = .69), serious adverse events (P = .35), and all-cause death (P = .48). However, PFO closure, was associated with increased new-onset AF/AFL (P < .001), risk of pulmonary embolism (P = .04), and device-related complications (P < .001). On a subgroup analysis, stroke recurrence rate remained lower in PFO closure arm regardless of the type of closure device used (P interaction  = .50), or the presence of substantial shunt in the majority of study population (P interaction  = .13). Transcatheter PFO closure reduces the recurrence of stroke compared with medical therapy alone, with no significant safety concerns. Close follow-up of patients after PFO closure is recommended to detect new-onset atrial arrhythmias. © 2018 Wiley Periodicals, Inc.

  15. Accelerated re-epithelialization of partial-thickness skin wounds by a topical betulin gel: Results of a randomized phase III clinical trials program.

    PubMed

    Barret, Juan P; Podmelle, Fred; Lipový, Břetislav; Rennekampff, Hans-Oliver; Schumann, Hauke; Schwieger-Briel, Agnes; Zahn, Tobias R; Metelmann, Hans-Robert

    2017-09-01

    The clinical significance of timely re-epithelialization is obvious in burn care, since delayed wound closure is enhancing the risk of wound site infection and extensive scarring. Topical treatments that accelerate wound healing are urgently needed to reduce these sequelae. Evidence from preliminary studies suggests that betulin can accelerate the healing of different types of wounds, including second degree burns and split-thickness skin graft wounds. The goal of this combined study program consisting of two randomized phase III clinical trials in parallel is to evaluate whether a topical betulin gel (TBG) is accelerating re-epithelialization of split-thickness skin graft (STSG) donor site wounds compared to standard of care. Two parallel blindly evaluated, randomised, controlled, multicentre phase III clinical trials were performed in adults undergoing STSG surgery (EudraCT nos. 2012-003390-26 and 2012-000777-23). Donor site wounds were split into two equal halves and randomized 1:1 to standard of care (a non-adhesive moist wound dressing) or standard of care plus TBG consisting of 10% birch bark extract and 90% sunflower oil (Episalvan, Birken AG, Niefern-Oeschelbronn, Germany). The primary efficacy assessment was the intra-individual difference in time to wound closure assessed from digital photographs by three blinded experts. A total of 219 patients were included and treated in the two trials. Wounds closed faster with TBG than without it (15.3 vs. 16.5 days; mean intra-individual difference=-1.1 days [95% CI, -1.5 to -0.7]; p<0.0001). This agreed with unblinded direct clinical assessment (difference=-2.1 days [95% CI, -2.7 to -1.5]; p<0.0001). Adverse events possibly related to treatment were mild or moderate and mostly at the application site. TBG accelerates re-epithelialization of partial thickness wounds compared to the current standard of care, providing a well-tolerated contribution to burn care in practice. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. 40 CFR 267.143 - Financial assurance for closure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... procedures engagement in accordance with professional auditing standards and shall describe the procedures... parent corporation of the owner or operator, or a firm with a “substantial business relationship” with... the guarantor is a firm with a “substantial business relationship” with the owner or operator, this...

  17. 40 CFR 264.14 - Security.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Security. 264.14 Section 264.14... Standards § 264.14 Security. (a) The owner or operator must prevent the unknowing entry, and minimize the...) for discussion of security requirements at disposal facilities during the post-closure care period...

  18. 40 CFR 265.14 - Security.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Security. 265.14 Section 265.14... Facility Standards § 265.14 Security. (a) The owner or operator must prevent the unknowing entry, and...) for discussion of security requirements at disposal facilities during the post-closure care period...

  19. 40 CFR 264.14 - Security.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Security. 264.14 Section 264.14... Standards § 264.14 Security. (a) The owner or operator must prevent the unknowing entry, and minimize the...) for discussion of security requirements at disposal facilities during the post-closure care period...

  20. 40 CFR 264.14 - Security.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Security. 264.14 Section 264.14... Standards § 264.14 Security. (a) The owner or operator must prevent the unknowing entry, and minimize the...) for discussion of security requirements at disposal facilities during the post-closure care period...

Top