Simon, Scott; Grey, Casey Paul; Massenzo, Trisha; Simpson, David G; Longest, P Worth
2014-11-01
Current technology for endovascular thrombectomy in ischemic stroke utilizes static loading and is successful in approximately 85% of cases. Existing technology uses either static suction (applied via a continuous pump or syringe) or flow arrest with a proximal balloon. In this paper we evaluate the potential of cyclic loading in aspiration thrombectomy. In order to evaluate the efficacy of cyclic aspiration, a model was created using a Penumbra aspiration system, three-way valve and Penumbra 5Max catheter. Synthetic clots were aspirated at different frequencies and using different aspiration mediums. Success or failure of clot removal and time were recorded. All statistical analyses were based on either a one-way or two-way analysis of variance, Holm-Sidak pairwise multiple comparison procedure (α=0.05). Cyclic aspiration outperformed static aspiration in overall clot removal and removal speed (p<0.001). Within cyclic aspiration, Max Hz frequencies (∼6.3 Hz) cleared clots faster than 1 Hz (p<0.001) and 2 Hz (p=0.024). Loading cycle dynamics (specific pressure waveforms) affected speed and overall clearance (p<0.001). Water as the aspiration medium was more effective at clearing clots than air (p=0.019). Cyclic aspiration significantly outperformed static aspiration in speed and overall clearance of synthetic clots in our experimental model. Within cyclic aspiration, efficacy is improved by increasing cycle frequency, utilizing specific pressure cycle waveforms and using water rather than air as the aspiration medium. These findings provide a starting point for altering existing thrombectomy technology or perhaps the development of new technologies with higher recanalization rates. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Clot stability as a determinant of effective factor VIII replacement in hemophilia A.
Leong, L; Chernysh, I N; Xu, Y; Sim, D; Nagaswami, C; de Lange, Z; Kosolapova, S; Cuker, A; Kauser, K; Weisel, J W
2017-10-01
Factor VIII (FVIII) replacement is standard of care for patients with hemophilia A (HemA); however, patient response does not always correlate with FVIII levels. We hypothesize this may be in part due to the physical properties of clots and contributions of fibrin, platelets, and erythrocytes, which may be important for hemostasis. To understand how FVIII contributes to effective hemostasis in terms of clot structure and mechanical properties. In vitro HemA clots in human plasma or whole blood were analyzed using turbidity waveform analysis, confocal microscopy, and rheometry with or without added FVIII. In vivo clots from saphenous vein puncture in wild-type and HemA mice with varying FVIII levels were examined using scanning electron microscopy. FVIII profoundly affected HemA clot structure and physical properties; added FVIII converted the open and porous fibrin meshwork and low stiffness of HemA clots to a highly branched and dense meshwork with higher stiffness. Platelets and erythrocytes incorporated into clots modulated clot properties. The clots formed in the mouse saphenous vein model contained variable amounts of compressed erythrocytes (polyhedrocytes), fibrin, and platelets depending on the levels of FVIII, correlating with bleeding times. FVIII effects on clot characteristics were dose-dependent and reached a maximum at ~25% FVIII, such that HemA clots formed with this level of FVIII resembled clots from unaffected controls. Effective clot formation can be achieved in HemA by replacement therapy, which alters the architecture of the fibrin network and associated cells, thus increasing clot stiffness and decreasing clot permeability.
The application of large amplitude oscillatory stress in a study of fully formed fibrin clots
NASA Astrophysics Data System (ADS)
Lamer, T. F.; Thomas, B. R.; Curtis, D. J.; Badiei, N.; Williams, P. R.; Hawkins, K.
2017-12-01
The suitability of controlled stress large amplitude oscillatory shear (LAOStress) for the characterisation of the nonlinear viscoelastic properties of fully formed fibrin clots is investigated. Capturing the rich nonlinear viscoelastic behaviour of the fibrin network is important for understanding the structural behaviour of clots formed in blood vessels which are exposed to a wide range of shear stresses. We report, for the first time, that artefacts due to ringing exist in both the sample stress and strain waveforms of a LAOStress measurement which will lead to errors in the calculation of nonlinear viscoelastic properties. The process of smoothing the waveforms eliminates these artefacts whilst retaining essential rheological information. Furthermore, we demonstrate the potential of LAOStress for characterising the nonlinear viscoelastic properties of fibrin clots in response to incremental increases of applied stress up to the point of fracture. Alternating LAOStress and small amplitude oscillatory shear measurements provide detailed information of reversible and irreversible structural changes of the fibrin clot as a consequence of elevated levels of stress. We relate these findings to previous studies involving large scale deformations of fibrin clots. The LAOStress technique may provide useful information to help understand why some blood clots formed in vessels are stable (such as in deep vein thrombosis) and others break off (leading to a life threatening pulmonary embolism).
Kim, S K; Yoon, W; Kim, T S; Kim, H S; Heo, T W; Park, M S
2015-09-01
It is unclear whether clot composition analysis is helpful to predict a stroke mechanism in acute large vessel occlusion. In addition, the relationship between early vessel signs on imaging studies and clot compositions has been poorly understood. The purpose of this study was to elucidate the relationship between clot composition and stroke etiology following mechanical thrombectomy and to investigate the effect of varied clot compositions on gradient-echo MR imaging of clots. Histopathologic analysis of retrieved clots from 37 patients with acute MCA occlusion was performed. Patients underwent gradient-echo imaging before endovascular therapy. Retrieved clots underwent semiquantitative proportion analysis to quantify red blood cells, fibrin, platelets, and white blood cells by area. Correlations between clot compositions and stroke subtypes and susceptibility vessel signs on gradient-echo imaging were assessed. Stroke etiology was classified as cardioembolism in 22 patients (59.4%), large-artery atherosclerosis in 8 (21.6%), and undetermined in 7 (18.9%). The clots from cardioembolism had a significantly higher proportion of red blood cells (37.8% versus 16.9%, P = .031) and a lower proportion of fibrin (32.3% versus 48.5%, P = .044) compared with those from large-artery atherosclerosis. The proportion of red blood cells was significantly higher in clots with a susceptibility vessel sign than in those without it (48.0% versus 1.9%, P < .001), whereas the proportions of fibrin (26.4% versus 57.0%, P < .001) and platelets (22.6% versus 36.9%, P = .011) were significantly higher in clots without a susceptibility vessel sign than those with it. The histologic composition of clots retrieved from cerebral arteries in patients with acute stroke differs between those with cardioembolism and large-artery atherosclerosis. In addition, a susceptibility vessel sign on gradient-echo imaging is strongly associated with a high proportion of red blood cells and a low proportion of fibrin and platelets in retrieved clots. © 2015 by American Journal of Neuroradiology.
Whole blood clot optical clearing for nondestructive 3D imaging and quantitative analysis
Höök, Peter; Brito-Robinson, Teresa; Kim, Oleg; Narciso, Cody; Goodson, Holly V.; Weisel, John W.; Alber, Mark S.; Zartman, Jeremiah J.
2017-01-01
A technological revolution in both light and electron microscopy imaging now allows unprecedented views of clotting, especially in animal models of hemostasis and thrombosis. However, our understanding of three-dimensional high-resolution clot structure remains incomplete since most of our recent knowledge has come from studies of relatively small clots or thrombi, due to the optical impenetrability of clots beyond a few cell layers in depth. Here, we developed an optimized optical clearing method termed cCLOT that renders large whole blood clots transparent and allows confocal imaging as deep as one millimeter inside the clot. We have tested this method by investigating the 3D structure of clots made from reconstituted pre-labeled blood components yielding new information about the effects of clot contraction on erythrocytes. Although it has been shown recently that erythrocytes are compressed to form polyhedrocytes during clot contraction, observations of this phenomenon have been impeded by the inability to easily image inside clots. As an efficient and non-destructive method, cCLOT represents a powerful research tool in studying blood clot structure and mechanisms controlling clot morphology. Additionally, cCLOT optical clearing has the potential to facilitate imaging of ex vivo clots and thrombi derived from healthy or pathological conditions. PMID:28856043
Stachowicz, Aneta; Siudut, Jakub; Suski, Maciej; Olszanecki, Rafał; Korbut, Ryszard; Undas, Anetta; Wiśniewski, Jacek R
2017-01-01
It is well known that fibrin network binds a large variety of proteins, including inhibitors and activators of fibrinolysis, which may affect clot properties, such as stability and susceptibility to fibrinolysis. Specific plasma clot composition differs between individuals and may change in disease states. However, the plasma clot proteome has not yet been in-depth analyzed, mainly due to technical difficulty related to the presence of a highly abundant protein-fibrinogen and fibrin that forms a plasma clot. The aim of our study was to optimize quantitative proteomic analysis of fibrin clots prepared ex vivo from citrated plasma of the peripheral blood drawn from patients with prior venous thromboembolism (VTE). We used a multiple enzyme digestion filter aided sample preparation, a multienzyme digestion (MED) FASP method combined with LC-MS/MS analysis performed on a Proxeon Easy-nLC System coupled to the Q Exactive HF mass spectrometer. We also evaluated the impact of peptide fractionation with pipet-tip strong anion exchange (SAX) method on the obtained results. Our proteomic approach revealed 476 proteins repeatedly identified in the plasma fibrin clots from patients with VTE including extracellular vesicle-derived proteins, lipoproteins, fibrinolysis inhibitors, and proteins involved in immune responses. The MED FASP method using three different enzymes: LysC, trypsin and chymotrypsin increased the number of identified peptides and proteins and their sequence coverage as compared to a single step digestion. Peptide fractionation with a pipet-tip strong anion exchange (SAX) protocol increased the depth of proteomic analyses, but also extended the time needed for sample analysis with LC-MS/MS. The MED FASP method combined with a label-free quantification is an excellent proteomic approach for the analysis of fibrin clots prepared ex vivo from citrated plasma of patients with prior VTE.
Blood coagulation abnormalities in multibacillary leprosy patients.
Silva, Débora Santos da; Teixeira, Lisandra Antonia Castro; Beghini, Daniela Gois; Ferreira, André Teixeira da Silva; Pinho, Márcia de Berredo Moreira; Rosa, Patricia Sammarco; Ribeiro, Marli Rambaldi; Freire, Monica Di Calafiori; Hacker, Mariana Andrea; Nery, José Augusto da Costa; Pessolani, Maria Cristina Vidal; Tovar, Ana Maria Freire; Sarno, Euzenir Nunes; Perales, Jonas; Bozza, Fernando Augusto; Esquenazi, Danuza; Monteiro, Robson Queiroz; Lara, Flavio Alves
2018-03-01
Leprosy is a chronic dermato-neurological disease caused by Mycobacterium leprae infection. In 2016, more than 200,000 new cases of leprosy were detected around the world, representing the most frequent cause of infectious irreversible deformities and disabilities. In the present work, we demonstrate a consistent procoagulant profile on 40 reactional and non-reactional multibacillary leprosy patients. A retrospective analysis in search of signs of coagulation abnormalities among 638 leprosy patients identified 35 leprosy patients (5.48%) which displayed a characteristic lipid-like clot formed between blood clot and serum during serum harvesting, herein named 'leprosum clot'. Most of these patients (n = 16, 45.7%) belonged to the lepromatous leprosy pole of the disease. In addition, formation of the leprosum clot was directly correlated with increased plasma levels of soluble tissue factor and von Willebrand factor. High performance thin layer chromatography demonstrated a high content of neutral lipids in the leprosum clot, and proteomic analysis demonstrated that the leprosum clot presented in these patients is highly enriched in fibrin. Remarkably, differential 2D-proteomics analysis between leprosum clots and control clots identified two proteins present only in leprosy patients clots: complement component 3 and 4 and inter-alpha-trypsin inhibitor family heavy chain-related protein (IHRP). In agreement with those observations we demonstrated that M. leprae induces hepatocytes release of IHRP in vitro. We demonstrated that leprosy MB patients develop a procoagulant status due to high levels of plasmatic fibrinogen, anti-cardiolipin antibodies, von Willebrand factor and soluble tissue factor. We propose that some of these components, fibrinogen for example, presents potential as predictive biomarkers of leprosy reactions, generating tools for earlier diagnosis and treatment of these events.
Chung, Tze-Wen; Lin, Pei-Yi; Wang, Shoei-Shen; Chen, Yen-Fung
2014-01-01
Chitosan nanoparticles (NPs) decorated with adenosine diphosphate (ADP) (ANPs) or fibrinogen (FNPs) were used to fabricate hemostatic NPs that can shorten blood clotting time and prevent severe local hemorrhage. The structure and mechanical properties of the blood clot induced with ANP (clot/ANP) or FNP (clot/FNP) were also investigated. The NPs, ANPs, and FNPs, which had particle sizes of 245.1±14.0, 251.0±9.8, and 326.5±14.5 nm and zeta potentials of 24.1±0.5, 20.6±1.9, and 15.3±1.5 mV (n=4), respectively, were fabricated by ionic gelation and then decorated with ADP and fibrinogen. The zeta potentials and Fourier transform infrared (FTIR) spectroscopy of the NPs confirmed that their surfaces were successfully coated with ADP and fibrinogen. The scanning electron microscope (SEM) micrographs of the structure of the clot induced with “undecorated” chitosan NPs (clot/NP), clot/ANP, and clot/FNP (at 0.05 wt%) were different, after citrated bloods had been recalcified by a calcium chloride solution containing NPs, ANPs, or FNPs. This indicated that many NPs adhered on the membrane surfaces of red blood cells, that ANPs induced many platelet aggregates, and that FNPs were incorporated into the fibrin network in the clots. Measurements of the blood clotting times (Tc) of blood clot/NPs, clot/ANPs, and clot/FNPs, based on 90% of ultimate frequency shifts measured on a quartz crystal microbalance (QCM), were significantly (P<0.05) (n=4) shorter than that of a clot induced by a phosphate-buffered solution (PBS) (clot/PBS) (63.6%±3.1%, 48.3%±6.2%, and 63.2%±4.7%, respectively). The ΔF2 values in the spectra of frequency shifts associated with the propagation of fibrin networks in the clot/ANPs and clot/FNPs were significantly lower than those of clot/PBS. Interestingly, texture profile analysis of the compressional properties showed significantly lower hardness and compressibility in clot/NPs and clot/ANPs (P<0.05 or better) (n=4) compared with clot/PBS and clot/FNPs. Accordingly, among the hemostatic NPs, ANP substantially reduced blood clotting times, ΔF2 values, and compression flow properties of the clot. Hence, ANPs have potential applications for preventing severe local hemorrhage. PMID:24729701
Chung, Tze-Wen; Lin, Pei-Yi; Wang, Shoei-Shen; Chen, Yen-Fung
2014-01-01
Chitosan nanoparticles (NPs) decorated with adenosine diphosphate (ADP) (ANPs) or fibrinogen (FNPs) were used to fabricate hemostatic NPs that can shorten blood clotting time and prevent severe local hemorrhage. The structure and mechanical properties of the blood clot induced with ANP (clot/ANP) or FNP (clot/FNP) were also investigated. The NPs, ANPs, and FNPs, which had particle sizes of 245.1 ± 14.0, 251.0 ± 9.8, and 326.5 ± 14.5 nm and zeta potentials of 24.1 ± 0.5, 20.6 ± 1.9, and 15.3 ± 1.5 mV (n=4), respectively, were fabricated by ionic gelation and then decorated with ADP and fibrinogen. The zeta potentials and Fourier transform infrared (FTIR) spectroscopy of the NPs confirmed that their surfaces were successfully coated with ADP and fibrinogen. The scanning electron microscope (SEM) micrographs of the structure of the clot induced with "undecorated" chitosan NPs (clot/NP), clot/ANP, and clot/FNP (at 0.05 wt%) were different, after citrated bloods had been recalcified by a calcium chloride solution containing NPs, ANPs, or FNPs. This indicated that many NPs adhered on the membrane surfaces of red blood cells, that ANPs induced many platelet aggregates, and that FNPs were incorporated into the fibrin network in the clots. Measurements of the blood clotting times (Tc) of blood clot/NPs, clot/ANPs, and clot/FNPs, based on 90% of ultimate frequency shifts measured on a quartz crystal microbalance (QCM), were significantly (P<0.05) (n=4) shorter than that of a clot induced by a phosphate-buffered solution (PBS) (clot/PBS) (63.6% ± 3.1%, 48.3% ± 6.2%, and 63.2% ± 4.7%, respectively). The ΔF2 values in the spectra of frequency shifts associated with the propagation of fibrin networks in the clot/ANPs and clot/FNPs were significantly lower than those of clot/PBS. Interestingly, texture profile analysis of the compressional properties showed significantly lower hardness and compressibility in clot/NPs and clot/ANPs (P<0.05 or better) (n=4) compared with clot/PBS and clot/FNPs. Accordingly, among the hemostatic NPs, ANP substantially reduced blood clotting times, ΔF2 values, and compression flow properties of the clot. Hence, ANPs have potential applications for preventing severe local hemorrhage.
Soleimani, Sajjad; Dubini, Gabriele; Pennati, Giancarlo
2014-10-01
According to a number of clinical studies, coronary aspiration catheters are useful tools to remove a thrombus (blood clot) blocking a coronary artery. However, these thrombectomy devices may fail to remove the blood clot entirely. Few studies have been devoted to a systematic analysis of factors affecting clot aspiration. The geometric characteristics of the aspiration catheter, the physical properties of the thrombus, and the applied vacuum pressure are crucial parameters. In this study, the aspiration of a blood clot blocking a coronary bifurcation is computationally simulated. The clot is modeled as a highly viscous fluid, and a two-phase (blood and clot) problem is solved. The effects of geometric variations in the tip of the coronary catheter, including lateral hole size and location, are investigated considering different aspiration pressures and clot viscosities. A Bird-Carreau model is adopted for blood viscosity, while a power law model is used to describe the clot rheology. Computational results for blood clot aspiration show that the presence of holes in the lateral part of the tip of the catheter can be beneficial depending on clot viscosity, hole features, and applied aspiration pressure. In general, the holes are beneficial when the clot viscosity is low, while aspiration catheters without any extra lateral holes exhibit better performance for higher clot viscosity. However, when higher aspiration pressures are applied, the catheters tend to behave relatively similarly in removing clots with various viscosities, reducing the role of the clot viscosity. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
2014-01-01
facilitates analysis of fibrin generation and its modulation by clotting factors : implications for hemostasis-enhancing therapies† Alexander Y...investigate the ability of fibrinogen and a recently proposed prothrombin complex concentrate composition, PCC-AT (a combination of the clotting factors II...kinetics. Moreover, the model qualitatively predicted the impact of tissue factor and tPA/tenecteplase level variations on the fibrin output. In the
Masomi-Bornwasser, Julia; Müller-Werkmeister, Hendrik; Kantelhardt, Sven Rainer; König, Jochem; Kempski, Oliver; Giese, Alf
2017-01-01
Hematoma lysis with recombinant tissue plasminogen activator (rtPA) has emerged as an alternative therapy for spontaneous intracerebral hemorrhage (ICH). Optimal dose and schedule are still unclear. The aim of this study was to create a reliable in vitro blood clot model for investigation of optimal drug dose and timing. An in vitro clot model was established, using 25 mL and 50 mL of human blood. Catheters were placed into the clots and three groups, using intraclot application of rtPA, placebo, and catheter alone, were analyzed. Dose-response relationship, repetition, and duration of rtPA treatment and its effectiveness in aged clots were investigated. A significant relative end weight difference was found in rtPA treated clots compared to catheter alone (p = 0.002) and placebo treated clots (p < 0.001). Dose-response analysis revealed 95% effective dose around 1 mg rtPA in 25 and 50 mL clots. Approximately 80% of relative clot lysis could be achieved after 15 min incubation. Lysis of aged clots was less effective. A new clot model for in vitro investigation was established. Our data suggest that current protocols for rtPA based ICH therapy may be optimized by using less rtPA at shorter incubation times. PMID:28459065
Keric, Naureen; Masomi-Bornwasser, Julia; Müller-Werkmeister, Hendrik; Kantelhardt, Sven Rainer; König, Jochem; Kempski, Oliver; Giese, Alf
2017-01-01
Hematoma lysis with recombinant tissue plasminogen activator (rtPA) has emerged as an alternative therapy for spontaneous intracerebral hemorrhage (ICH). Optimal dose and schedule are still unclear. The aim of this study was to create a reliable in vitro blood clot model for investigation of optimal drug dose and timing. An in vitro clot model was established, using 25 mL and 50 mL of human blood. Catheters were placed into the clots and three groups, using intraclot application of rtPA, placebo, and catheter alone, were analyzed. Dose-response relationship, repetition, and duration of rtPA treatment and its effectiveness in aged clots were investigated. A significant relative end weight difference was found in rtPA treated clots compared to catheter alone ( p = 0.002) and placebo treated clots ( p < 0.001). Dose-response analysis revealed 95% effective dose around 1 mg rtPA in 25 and 50 mL clots. Approximately 80% of relative clot lysis could be achieved after 15 min incubation. Lysis of aged clots was less effective. A new clot model for in vitro investigation was established. Our data suggest that current protocols for rtPA based ICH therapy may be optimized by using less rtPA at shorter incubation times.
Endogenous fibrinolysis facilitates clot retraction in vivo.
Samson, Andre L; Alwis, Imala; Maclean, Jessica A A; Priyananda, Pramith; Hawkett, Brian; Schoenwaelder, Simone M; Jackson, Shaun P
2017-12-07
Clot retraction refers to the process whereby activated platelets transduce contractile forces onto the fibrin network of a thrombus, which over time increases clot density and decreases clot size. This process is considered important for promoting clot stability and maintaining blood vessel patency. Insights into the mechanisms regulating clot retraction at sites of vascular injury have been hampered by a paucity of in vivo experimental models. By pairing localized vascular injury with thrombin microinjection in the mesenteric circulation of mice, we have demonstrated that the fibrin network of thrombi progressively compacts over a 2-hour period. This was a genuine retraction process, as treating thrombi with blebbistatin to inhibit myosin IIa-mediated platelet contractility prevented shrinkage of the fibrin network. Real-time confocal analysis of fibrinolysis after recombinant tissue-type plasminogen activator (tPA) administration revealed that incomplete proteolysis of fibrin polymers markedly facilitated clot retraction. Similarly, inhibiting endogenous fibrinolysis with tranexamic acid reduced retraction of fibrin polymers in vivo. In vitro clot retraction experiments indicated that subthreshold doses of tPA facilitated clot retraction through a plasmin-dependent mechanism. These effects correlated with changes in the elastic modulus of fibrin clots. These findings define the endogenous fibrinolytic system as an important regulator of clot retraction, and show that promoting clot retraction is a novel and complementary means by which fibrinolytic enzymes can reduce thrombus size. © 2017 by The American Society of Hematology.
Comparison of fibrin clots derived from peripheral blood and bone marrow.
Shoji, Takeshi; Nakasa, Tomoyuki; Yoshizuka, Masaaki; Yamasaki, Takuma; Yasunaga, Yuji; Adachi, Nobuo; Ochi, Mitsuo
2017-03-01
Autologous fibrin clots derived from peripheral blood (pb-fibrin clot) and bone marrow (bm-fibrin clot) are thought to be effective for tissue regeneration. However, there is no report detailing the amount of growth factors in pb-/bm-fibrin clot. In this study we evaluated the amount of growth factors in human pb-/bm-fibrin clot, and prove the validity of fibrin clot for clinical use. Human pb-/bm-fibrin clots were obtained during surgery. In the first experiment, enzyme-linked immunosorbent assay (ELISA) was performed for detecting the amount of vascular endothelial growth factor (VEGF), epidermal growth factor (EGF), insulin-like growth factor-1 (IGF-1), fibroblast growth factor basic (bFGF), hepatocyte growth factor (HGF), transforming growth factor-beta (TGF-β), platelet derived-growth factors-AB (PDGF-AB), and stromal cell-derived factor-1 (SDF-1). In the second experiment, the efficacy of fibrin clot on the osteogenic differentiation and fibroblast proliferation was evaluated. Pb-/bm-fibrin clots were incubated in human osteoblast derived from mesenchymal stromal cells (MSCs) or human skin fibroblast. Alizarin red staining and real-time PCR (COL1A1, RUNX2) were performed for the detection of osteogenic potential. Cell-growth assay (WST-8) and real-time PCR (COL1A1) were also performed for the detection of the potential of fibroblast proliferation. ELISA analysis revealed that the amount of VEGF, HGF, bFGF, IGF-1, and SDF-1 of bm-fibrin clot group is higher than that of pb-fibrin clot group with statistical differences. Besides, we confirmed that bm-fibrin clot has much potential for the osteogenic differentiation and fibroblast proliferation. The positive outcomes confirm the efficacy of pb-/bm-fibrin clot, and bm-fibrin clot was proved to have much potential for tissue regeneration compared with pb-fibrin clot. The current study showed the potential of a strategy for regenerative medicine using bm-fibrin clot.
Plasma clots gelled by different amounts of calcium for stem cell delivery.
Gessmann, Jan; Seybold, Dominik; Peter, Elvira; Schildhauer, Thomas Armin; Köller, Manfred
2013-01-01
Freshly prepared autologous plasma clots may serve as a carrier matrix for expanded multipotent mesenchymal stromal cells (MSCs) or bone marrow cells. By varying the calcium concentration, plasma clots with different properties can be produced. The purpose of this in vitro study was to determine the optimal calcium concentrations for the clotting process, intra-clot cell viability, and clot lysis. Different plasma clots were prepared by adding an equal volume of RPMI1640 (with or without MSCs) to citrate plasma (either containing platelets or platelet-free). Clotting was initiated by the addition of CaCl(2) (10 g/100 ml H(2)O, 10 % solution). The final concentration of CaCl(2) ranged from 1 to 10 % by volume of plasma. Viability and distribution of the MSCs were analysed by calcein-AM/propidium iodide staining. MSC-embedded plasma clots were dissolved with trypsin (0.25 %), and recovered cells were further incubated for 1 week under cell culture conditions. The viability of MSCs embedded in clots formed by the addition of 1-8 % by volume CaCl2 was not affected by incubation of up to 1 week. In contrast, clots produced by higher volumes of CaCl(2) solutions (9-10 % by volume of plasma) showed decreased numbers of viable cells. Intra-clot cell proliferation was highest in clots produced by addition of 5 % CaCl(2) by plasma volume. Osteocalcin release was not influenced in platelet-free plasma but decreased in platelet-containing plasma. Morphological analysis of stained recovered MSCs revealed that lysis of the plasma clot did not affect cell morphology or subsequent spontaneous proliferation. Clot formation and clot stability can be controlled by changing the concentration of CaCl(2) added to plasma. The addition of 5 % CaCl(2) produced a plasma clot with optimal results for stem cell delivery.
Fibrin network changes in neonates after cardiopulmonary bypass
Brown, Ashley C.; Hannan, Riley; Timmins, Lucas H.; Fernandez, Janet D.; Barker, Thomas H.; Guzzetta, Nina A.
2016-01-01
Background Quantitative and qualitative differences exist between the hemostatic systems of neonates and adults, among them the presence of ‘fetal’ fibrinogen, a qualitatively dysfunctional form of fibrinogen that exists until one year of age. The consequences of ‘fetal’ fibrinogen on clot structure in neonates, particularly in the context of surgical associated bleeding, have not been well characterized. Here we examine the sequential changes in clotting components and resultant clot structure in a small sample of neonates undergoing cardiac surgery and cardiopulmonary bypass (CPB). Methods Blood samples were collected from neonates (n=10) before surgery, immediately after CPB and following the transfusion of cryoprecipitate (i.e. adult fibrinogen component). Clots were formed from patient samples or purified neonatal and adult fibrinogen. Clot structure was analyzed using confocal microscopy. Results Clots formed from plasma obtained after CPB and after transfusion were more porous than baseline clots. Analysis of clots formed from purified neonatal and adult fibrinogen, demonstrated that at equivalent fibrinogen concentrations, neonatal clots lack three-dimensional structure while adult clots were denser with significant three-dimensional structure. Clots formed from a combination of purified neonatal and adult fibrinogen were less homogenous than those formed from either purified adult or neonatal fibrinogen. Conclusions Our results confirm that significant differences exist in clot structure between neonates and adults, and that neonatal and adult fibrinogen may not integrate well. These findings suggest that differential treatment strategies for neonates should be pursued to reduce the demonstrated morbidity of blood product transfusion. PMID:26914227
Evans, Phillip A; Hawkins, Karl; Morris, Roger H K; Thirumalai, Naresh; Munro, Roger; Wakeman, Lisa; Lawrence, Matthew J; Williams, P Rhodri
2010-10-28
Here we report the first application of a fractal analysis of the viscoelastic properties of incipient blood clots. We sought to ascertain whether the incipient clot's fractal dimension, D(f,) could be used as a functional biomarker of hemostasis. The incipient clot is formed at the gel point (GP) of coagulating blood, the GP demarcating a functional change from viscoelastic liquid to a viscoelastic solid. Incipient clots formed in whole healthy blood show a clearly defined value of D(f) within a narrow range that represents an index of clotting in health, where D(f) = 1.74 (± 0.07). A significant relationship is found between the incipient clot formation time, T(GP), and the activated partial thromboplastin time, whereas the association of D(f) with the microstructural characteristics of the incipient clot is supported by its significant correlation with fibrinogen. Our study reveals that unfractionated heparin not only prolongs the onset of clot formation but has a significant effect on its fractal microstructure. A progressive increase in unfractionated heparin concentration results in a linear decrease in D(f) and a corresponding prolongation in T(GP). The results represent a new, quantitative measure of clot quality derived from measurements on whole blood samples.
Removal of Chronic Intravascular Blood Clots using Liquid Plasma
NASA Astrophysics Data System (ADS)
Jung, Jae-Chul; Choi, Myeong; Koo, Il; Yu, Zengqi; Collins, George
2011-10-01
An electrical embolectomy device for removing chronic intravascular blood clots using liquid plasma under saline environment was demonstrated. We employed a proxy experimental blood clot model of deep vein thrombosis (DVT) and actual equine blood clot. Thermal damage to contiguous tissue and the collagen denaturing via the plasma irradiation were investigated by histological analysis using birefringence of the tissue and verified by FT-IR spectroscopic study, respectively, which showed the high removal rate up to 2 mm per minute at room temperature and small thermal damage less than 200 μm.
Co-ordinated spatial propagation of blood plasma clotting and fibrinolytic fronts
Zhalyalov, Ansar S.; Panteleev, Mikhail A.; Gracheva, Marina A.; Ataullakhanov, Fazoil I.
2017-01-01
Fibrinolysis is a cascade of proteolytic reactions occurring in blood and soft tissues, which functions to disintegrate fibrin clots when they are no more needed. In order to elucidate its regulation in space and time, fibrinolysis was investigated using an in vitro reaction-diffusion experimental model of blood clot formation and dissolution. Clotting was activated by a surface with immobilized tissue factor in a thin layer of recalcified blood plasma supplemented with tissue plasminogen activator (TPA), urokinase plasminogen activator or streptokinase. Formation and dissolution of fibrin clot was monitored by videomicroscopy. Computer systems biology model of clot formation and lysis was developed for data analysis and experimental planning. Fibrin clot front propagated in space from tissue factor, followed by a front of clot dissolution propagating from the same source. Velocity of lysis front propagation linearly depended on the velocity clotting front propagation (correlation r2 = 0.91). Computer model revealed that fibrin formation was indeed the rate-limiting step in the fibrinolysis front propagation. The phenomenon of two fronts which switched the state of blood plasma from liquid to solid and then back to liquid did not depend on the fibrinolysis activator. Interestingly, TPA at high concentrations began to increase lysis onset time and to decrease lysis propagation velocity, presumably due to plasminogen depletion. Spatially non-uniform lysis occurred simultaneously with clot formation and detached the clot from the procoagulant surface. These patterns of spatial fibrinolysis provide insights into its regulation and might explain clinical phenomena associated with thrombolytic therapy. PMID:28686711
NASA Technical Reports Server (NTRS)
Reed, G. L.; Matsueda, G. R.; Haber, E.
1992-01-01
Platelet clots resist fibrinolysis by plasminogen activators. We hypothesized that platelet factor XIII may enhance the fibrinolytic resistance of platelet-rich clots by catalyzing the crosslinking of alpha 2-antiplasmin (alpha 2AP) to fibrin. Analysis of plasma clot structure by polyacrylamide gel electrophoresis and immunoblotting revealed accelerated alpha 2AP-fibrin crosslinking in platelet-rich compared with platelet-depleted plasma clots. A similar study of clots formed with purified fibrinogen (depleted of factor XIII activity), isolated platelets, and specific factor XIII inhibitors indicated that this accelerated crosslinking was due to the catalytic activity of platelet factor XIII. Moreover, when washed platelets were aggregated by thrombin, there was evidence of platelet factor XIII-mediated crosslinking between platelet alpha 2AP and platelet fibrin(ogen). Specific inhibition (by a monoclonal antibody) of the alpha 2AP associated with washed platelet aggregates accelerated the fibrinolysis of the platelet aggregate. Thus in platelet-rich plasma clots, and in thrombin-induced platelet aggregates, platelet factor XIII actively formed alpha 2AP-fibrin crosslinks, which appeared to enhance the resistance of platelet-rich clots to fibrinolysis.
van Kempen, Thomas H S; Donders, Wouter P; van de Vosse, Frans N; Peters, Gerrit W M
2016-04-01
The mechanical properties determine to a large extent the functioning of a blood clot. These properties depend on the composition of the clot and have been related to many diseases. However, the various involved components and their complex interactions make it difficult at this stage to fully understand and predict properties as a function of the components. Therefore, in this study, a constitutive model is developed that describes the viscoelastic behavior of blood clots with various compositions. Hereto, clots are formed from whole blood, platelet-rich plasma and platelet-poor plasma to study the influence of red blood cells, platelets and fibrin, respectively. Rheological experiments are performed to probe the mechanical behavior of the clots during their formation. The nonlinear viscoelastic behavior of the mature clots is characterized using a large amplitude oscillatory shear deformation. The model is based on a generalized Maxwell model that accurately describes the results for the different rheological experiments by making the moduli and viscosities a function of time and the past and current deformation. Using the same model with different parameter values enables a description of clots with different compositions. A sensitivity analysis is applied to study the influence of parameter variations on the model output. The relative simplicity and flexibility make the model suitable for numerical simulations of blood clots and other materials showing similar behavior.
Insights into Fourier Synthesis and Analysis: Part 2--A Simplified Mathematics.
ERIC Educational Resources Information Center
Moore, Guy S. M.
1988-01-01
Introduced is an analysis of a waveform into its Fourier components. Topics included are simplified analysis of a square waveform, a triangular waveform, half-wave rectified alternating current (AC), and impulses. Provides the mathematical expression and simplified analysis diagram of each waveform. (YP)
Effect of the association between citric acid and EDTA on root surface etching.
Manzolli Leite, Fabio Renato; Nascimento, Gustavo Giacomelli; Manzolli Leite, Elza Regina; Leite, Amauri Antiquera; Cezar Sampaio, Josá Eduardo
2013-09-01
This study aims to compare the clot stabilization on root surfaces conditioned with citric acid and ethylenediamine-tetraacetic acid (EDTA). Scaled root samples (n = 100) were set in fve groups: group I-control group (saline solution); group II (24% EDTA); group III (25% citric acid); group IV (EDTA + citric acid); group V (citric acid + EDTA). Fifty samples were assessed using the root surface modifcation index (RSMI). The other 50 received a blood drop after conditioning. Clot formation was assessed using blood elements adhesion index (BEAI). A blind examiner evaluated photomicrographs. Statistical analysis considered p < 0.05. Groups-III and G-V attained the best results for RSMI and BEAI in comparison to control. The worst results for clot stabilization were seen in group-II. EDTA employment before citric acid (group-IV) reduced clot formation in comparison to citric acid use alone (group-III). Root conditioning with citric acid alone and before EDTA had the best results for smear layer removal and clot stabilization. EDTA inhibited clot stabilization on root surface and must have a residual activity once it has diminished clot adhesion to root even after citric acid conditioning. Thus, EDTA can be used to neutralize citric acid effects on periodontal cells without affecting clot stabilization. Clinical signifcance: To demonstrate that citric acid use on root surfaces previously affected by periodontal disease may favor clot stabilization and may have a benefcial effect on surgical outcomes. Also, EDTA can be used to neutralize citric acid effects on periodontal cells.
White, Nathan J; Martin, Erika J; Brophy, Donald F; Ward, Kevin R
2011-07-01
A significant proportion of severely injured patients develop early coagulopathy, characterized by abnormal clot formation, which impairs resuscitation and increases mortality. We have previously demonstrated an isolated decrease in clot strength by thrombelastography in a swine model of nonresuscitated traumatic shock. In order to more closely examine platelet-fibrin interactions in this setting, we define the observed decrease in clot strength in terms of platelet-induced clot contraction and clot elastic modulus using the Hemostasis Analysis System (HAS) (Hemodyne Inc., Richmond, Virginia, USA). Whole blood was sampled for HAS measurements, metabolic measurements, cell counts, and fibrinogen concentration at baseline prior to injury and again at a predetermined level of traumatic shock defined by oxygen debt. Male swine (N=17) received femur fracture and controlled arterial hemorrhage to achieve an oxygen debt of 80 ml/kg. Platelet counts were unchanged, but fibrinogen concentration was reduced significantly during shock (167.6 vs. 66.7 mg/dl, P=0.0007). Platelet contractile force generated during clot formation did not change during shock (11.7 vs. 10.4 kdynes, P=0.41), but clot elastic modulus was dynamically altered, resulting in a lower final value (22.9 vs. 17.3 kdynes/cm, P<0.0001). In this model of traumatic shock, platelet function was preserved, whereas terminal clot elastic modulus was reduced during shock in a manner most consistent with early changes in the mechanical properties of the developing fibrin fiber network.
Mechanisms of thrombolysis acceleration by cavitation
NASA Astrophysics Data System (ADS)
Weiss, Hope; Selvaraj, Prashanth; Ahadi, Golnaz; Voie, Arne; Hoelscher, Thilo; Okita, Kohei; Matsumoto, Yoichiro; Szeri, Andrew
2012-11-01
Recent studies, in vitro and in vivo, have shown that High Intensity Focused Ultrasound (HIFU) accelerates thrombolysis, the dissolution of blood clots, for ischemic stroke. Although the mechanisms are not fully understood, cavitation is thought to play an important role in sonothrombolysis. The damage to a blood clot's fibrin fiber network from cavitation in a HIFU field is studied using two independent approaches for an embedded bubble. One method is extended to the more important scenario of a bubble outside a blood clot that collapses asymmetrically creating a jet towards the clot. There is significantly more damage potential from a bubble undergoing cavitation collapse outside the clot compared to a rapidly expanding bubble embedded within the clot structure. Also, the effects of the physical properties of skull bone when a HIFU wave propagates through it are examined by use of computer simulation. The dynamics of a test bubble placed at the focus is used in understanding of the pressure field. All other things being equal, the analysis suggests that skull thickness can alter the wave at the focus, which in turn can change the nature of cavitation bubble dynamics and the amount of energy available for clot damage. Now at MSOE.
Watanabe, Masaki; Majidi, Shahram; Chaudhry, Saqib A; Qureshi, Adnan I
2012-12-01
We performed this study to identify echogenicity changes in clots and their correlations with histologic characteristics over time. B-mode sonography was performed at 2, 6, 24, and 48 hours after clot formation in venous blood from healthy donors. Analysis of echogenicity was performed by grayscale median measurement with normalization. We classified clots into 3 groups: dense, intermediate, and loose according to red blood cell (RBC) density on hematoxylin-eosin staining. Statistically significant chronologic changes in the grayscale median measurements were shown, with a trough at 6 hours and a peak at 24 hours (mean ± SD: 2 hours, 46.8 ± 4.1; 6 hours, 32.2 ± 13.1; 24 hours, 55.4 ± 9.9; 48 hours, 49.0 ± 13.9; P = .027). The grayscale median value was higher in dense RBC clots and lower in loose RBC clots (dense, 61.0 ± 10.6; intermediate, 49.4 ± 13.1; loose, 34.0 ± 12.1; P < .0353). Sonography using the grayscale median showed chronologic echogenicity changes in clots over a 48-hour period, and the grayscale median correlated with RBC density.
A Serpin Released by an Entomopathogen Impairs Clot Formation in Insect Defense System
Hao, YouJin; Balasubramanian, Natesan; Jing, Yingjun; Montiel, Rafael; Faria, Tiago Q.; Brito, Rui M.; Simões, Nelson
2013-01-01
Steinernema carpocapsae is an entomopathogenic nematode widely used for the control of insect pests due to its virulence, which is mainly attributed to the ability the parasitic stage has to overcome insect defences. To identify the mechanisms underlying such a characteristic, we studied a novel serpin-like inhibitor (sc-srp-6) that was detected in a transcriptome analysis. Recombinant Sc-SRP-6 produced in Escherichia coli had a native fold of serpins belonging to the α-1-peptidase family and exhibited inhibitory activity against trypsin and α-chymotrypsin with Ki of 0.42×10−7 M and 1.22×10−7 M, respectively. Functional analysis revealed that Sc-SRP-6 inhibits insect digestive enzymes, thus preventing the hydrolysis of ingested particles. Moreover, Sc-SRP-6 impaired the formation of hard clots at the injury site, a major insect defence mechanism against invasive pathogens. Sc-SRP-6 does not prevent the formation of clot fibres and the activation of prophenoloxidases but impairs the incorporation of the melanin into the clot. Binding assays showed a complex formation between Sc-SRP-6 and three proteins in the hemolymph of lepidopteran required for clotting, apolipophorin, hexamerin and trypsin-like, although the catalytic inhibition occurred exclusively in trypsin-like. This data allowed the conclusion that Sc-SRP-6 promotes nematode virulence by inhibiting insect gut juices and by impairing immune clot reaction. PMID:23874900
Fu, Xia; Liang, Xinling; Song, Li; Huang, Huigen; Wang, Jing; Chen, Yuanhan; Zhang, Li; Quan, Zilin; Shi, Wei
2014-04-01
To develop a predictive model for circuit clotting in patients with continuous renal replacement therapy (CRRT). A total of 425 cases were selected. 302 cases were used to develop a predictive model of extracorporeal circuit life span during CRRT without citrate anticoagulation in 24 h, and 123 cases were used to validate the model. The prediction formula was developed using multivariate Cox proportional-hazards regression analysis, from which a risk score was assigned. The mean survival time of the circuit was 15.0 ± 1.3 h, and the rate of circuit clotting was 66.6 % during 24 h of CRRT. Five significant variables were assigned a predicting score according to the regression coefficient: insufficient blood flow, no anticoagulation, hematocrit ≥0.37, lactic acid of arterial blood gas analysis ≤3 mmol/L and APTT < 44.2 s. The Hosmer-Lemeshow test showed no significant difference between the predicted and actual circuit clotting (R (2) = 0.232; P = 0.301). A risk score that includes the five above-mentioned variables can be used to predict the likelihood of extracorporeal circuit clotting in patients undergoing CRRT.
Identification of quantitative trait loci for fibrin clot phenotypes: The EuroCLOT study
Williams, Frances MK; Carter, Angela M; Kato, Bernet; Falchi, Mario; Bathum, Lise; Surdulescu, Gabriela; Kyvik, Kirsten Ohm; Palotie, Aarno; Spector, Tim D; Grant, Peter J
2012-01-01
Objectives Fibrin makes up the structural basis of an occlusive arterial thrombus and variability in fibrin phenotype relates to cardiovascular risk. The aims of the current study from the EU consortium EuroCLOT were to 1) determine the heritability of fibrin phenotypes and 2) identify QTLs associated with fibrin phenotypes. Methods 447 dizygotic (DZ) and 460 monozygotic (MZ) pairs of healthy UK Caucasian female twins and 199 DZ twin pairs from Denmark were studied. D-dimer, an indicator of fibrin turnover, was measured by ELISA and measures of clot formation, morphology and lysis were determined by turbidimetric assays. Heritability estimates and genome-wide linkage analysis were performed. Results Estimates of heritability for d-dimer and turbidometric variables were in the range 17 - 46%, with highest levels for maximal absorbance which provides an estimate of clot density. Genome-wide linkage analysis revealed 6 significant regions with LOD>3 on 5 chromosomes (5, 6, 9, 16 and 17). Conclusions The results indicate a significant genetic contribution to variability in fibrin phenotypes and highlight regions in the human genome which warrant further investigation in relation to ischaemic cardiovascular disorders and their therapy. PMID:19150881
Automated Analysis, Classification, and Display of Waveforms
NASA Technical Reports Server (NTRS)
Kwan, Chiman; Xu, Roger; Mayhew, David; Zhang, Frank; Zide, Alan; Bonggren, Jeff
2004-01-01
A computer program partly automates the analysis, classification, and display of waveforms represented by digital samples. In the original application for which the program was developed, the raw waveform data to be analyzed by the program are acquired from space-shuttle auxiliary power units (APUs) at a sampling rate of 100 Hz. The program could also be modified for application to other waveforms -- for example, electrocardiograms. The program begins by performing principal-component analysis (PCA) of 50 normal-mode APU waveforms. Each waveform is segmented. A covariance matrix is formed by use of the segmented waveforms. Three eigenvectors corresponding to three principal components are calculated. To generate features, each waveform is then projected onto the eigenvectors. These features are displayed on a three-dimensional diagram, facilitating the visualization of the trend of APU operations.
Szczepaniak, Piotr; Zabczyk, Michał; Undas, Anetta
2015-01-01
Background Formation of compact and poorly lysable clots has been reported in thromboembolic disorders. Little is known about clot properties in bleeding disorders. Objectives We hypothesized that more permeable and lysis-sensitive fibrin clots can be detected in women with heavy menstrual bleeding (HMB). Methods We studied 52 women with HMB of unknown cause and 52 age-matched control women. Plasma clot permeability (Ks), turbidity and efficiency of fibrinolysis, together with coagulation factors, fibrinolysis proteins, and platelet aggregation were measured. Results Women with HMB formed looser plasma fibrin clots (+16% [95%CI 7–18%] Ks) that displayed lower maximum absorbancy (-7% [95%CI -9 – -1%] ΔAbsmax), and shorter clot lysis time (-17% [95%CI -23 – -11%] CLT). The HMB patients and controls did not differ with regard to coagulation factors, fibrinogen, von Willebrand antigen, thrombin generation markers and the proportion of subjects with defective platelet aggregation. The patients had lower platelet count (-12% [95%CI -19 – -2%]), tissue plasminogen activator antigen (-39% [95%CI -41 – -29%] tPA:Ag), and plasminogen activator inhibitor-1 antigen (-28% [95%CI -38 – -18%] PAI-1:Ag) compared with the controls. Multiple regression analysis upon adjustment for age, body mass index, glucose, and fibrinogen showed that decreased tPA:Ag and shortened CLT were the independent predictors of HMB. Conclusions Increased clot permeability and susceptibility to fibrinolysis are associated with HMB, suggesting that altered plasma fibrin clot properties might contribute to bleeding disorders of unknown origin. PMID:25909989
Michalak, Gregory; Kadirvel, Ramanathan; Dai, Daying; Gilvarry, Michael; Duffy, Sharon; Kallmes, David F; McCollough, Cynthia; Leng, Shuai
2017-01-01
Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke. PMID:28604189
Königsbrügge, Oliver; Weigel, Günter; Quehenberger, Peter; Pabinger, Ingrid; Ay, Cihan
2018-02-07
The effect of direct oral anticoagulants (DOACs) on turbidimetric measurements of plasma clot formation and susceptibility to fibrinolysis may facilitate a comparison between different classes of anticoagulants in plasma samples. We obtained 424 citrate plasma samples from 226 atrial fibrillation patients on anticoagulation and 24 samples without anticoagulation serving as controls. As comparators, we measured the international normalized ratio (INR) for phenprocoumon samples (N = 166), anti-Xa for low molecular weight heparin (LMWH) samples (N = 42), and DOAC levels with mass spectrometry (dabigatran N = 40, rivaroxaban N = 110, apixaban N = 42). Plasma clot formation and lysis were recorded continuously on a photometer after addition of an activation mix (tissue factor 2 pmol/l and tissue plasminogen activator 333 ng/ml). We used linear regression and ANCOVA for correlation analysis. Clot formation lag phase was prolonged in the presence of anticoagulants in a concentration-dependent manner for DOACs (dabigatran Spearman r = 0.74; rivaroxaban r = 0.78; apixaban r = 0.72, all p < 0.0001), INR dependent for phenprocoumon (r = 0.59, p < 0.0001), anti-Xa level dependent in LMWH samples (r = 0.90, p < 0.0001). Maximum rate of clot formation and peak clot turbidity were reduced in the presence of anticoagulants, but correlated only moderately with the comparator measures of anticoagulation. The clot lysis time was inversely correlated with DOAC concentrations in the presence of recombinant thrombomodulin. A direct ex vivo comparison between the effects of different classes of anticoagulants is possible with turbidimetric measurement of plasma clot formation and lysis. Anticoagulation inhibited clot formation in a plasma concentration manner for DOACs, INR dependent for phenprocoumon, and anti-Xa dependent for LMWH. Susceptibility to fibrinolysis increased with increasing DOAC concentrations.
Kucheryavykh, Lilia Y; Dávila-Rodríguez, Josué; Rivera-Aponte, David E; Zueva, Lidia V; Washington, A Valance; Sanabria, Priscilla; Inyushin, Mikhail Y
2017-01-01
Platelets contain beta-amyloid precursor protein (APP) as well as Aβ peptide (Aβ) that can be released upon activation. During thrombosis, platelets are concentrated in clots and activated. We used in vivo fluorescent analysis and electron microscopy in mice to determine to what degree platelets are concentrated in clots. We used immunostaining to visualize Aβ after photothrombosis in mouse brains. Both in vivo results and electron microscopy revealed that platelets were 300-500 times more concentrated in clots than in non-clotted blood. After thrombosis in control mice, but not in thrombocytopenic animals, Aβ immunofluorescence was present inside blood vessels in the visual cortex and around capillaries in the entorhinal cortex. The increased concentration of platelets allows enhanced release of Aβ during thrombosis, suggesting an additional source of Aβ in the brains of Alzheimer's patients that may arise if frequent micro-thrombosis events occur in their brains. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Antiplatelet Usage Impacts Clot Density in Acute Anterior Circulation Ischemic Stroke
Pikija, Slaven; Magdic, Jozef; Lukic, Anita; Schreiber, Catharina; Mutzenbach, Johannes Sebastian; McCoy, Mark R.; Sellner, Johann
2016-01-01
We explored whether clot density in middle cerebral artery (MCA) occlusion is related to clinical variables, stroke etiology, blood constituents, and prestroke medication. We performed a retrospective chart review of patients with acute ischemic stroke of the anterior circulation admitted to two Central European stroke centers. The acquisition of non-contrast enhanced CT (NECT) and CT angiography (CTA) within 4.5 h of symptom onset was obligatory. We assessed the site of MCA occlusion as well as density, area, and length of the clot in 150 patients. The Hounsfield unit values for the clot were divided with contralateral MCA segment to yield relative Hounsfield Unit ratio (rHU). The site of the vessel occlusion (M1 vs. M2) and antiplatelet usage, but not stroke etiology, significantly influenced rHU. We found an inverse correlation of rHU with erythrocyte count (p < 0.001). The multivariate analysis revealed that a higher rHU (i.e., clot being more hyperdense) was more likely with the use of antiplatelets (OR 4.24, CI 1.10–16.31, p = 0.036). Erythrocyte (OR 0.18, CI 0.05–0.55, p = 0.003), and thrombocyte counts (OR 0.99, CI 0.98–0.99, p = 0.029) were associated with odds for more hypodense clots (lower rHU). Our study disclosed that antiplatelet therapy impacts the composition of intracranial clots of the anterior circulation. PMID:27563874
Brown, Jonathan; O'Brien, Caroline C; Lopes, Augusto C; Kolandaivelu, Kumaran; Edelman, Elazer R
2018-04-11
Stent thrombosis is a major complication of coronary stent and scaffold intervention. While often unanticipated and lethal, its incidence is low making mechanistic examination difficult through clinical investigation alone. Thus, throughout the technological advancement of these devices, experimental models have been indispensable in furthering our understanding of device safety and efficacy. As we refine model systems to gain deeper insight into adverse events, it is equally important that we continue to refine our measurement methods. We used digital signal processing in an established flow loop model to investigate local flow effects due to geometric stent features and ultimately its relationship to thrombus formation. A new metric of clot distribution on each microCT slice termed normalized clot ratio was defined to quantify this distribution. Three under expanded coronary bare-metal stents were run in a flow loop model to induce clotting. Samples were then scanned in a MicroCT machine and digital signal processing methods applied to analyze geometric stent conformation and spatial clot formation. Results indicated that geometric stent features play a significant role in clotting patterns, specifically at a frequency of 0.6225 Hz corresponding to a geometric distance of 1.606 mm. The magnitude-squared coherence between geometric features and clot distribution was greater than 0.4 in all samples. In stents with poor wall apposition, ranging from 0.27 mm to 0.64 mm maximum malapposition (model of real-world heterogeneity), clots were found to have formed in between stent struts rather than directly adjacent to struts. This early work shows how the combination of tools in the areas of image processing and signal analysis can advance the resolution at which we are able to define thrombotic mechanisms in in vitro models, and ultimately, gain further insight into clinical performance. Copyright © 2018 Elsevier Ltd. All rights reserved.
... News Physician Resources Professions Site Index A-Z Blood Clots Blood clots are semi-solid masses of blood ... evaluated? How are blood clots treated? What are blood clots? Blood clots are semi-solid masses of blood. ...
Shenkman, Boris; Livnat, Tami; Misgav, Mudi; Budnik, Ivan; Einav, Yulia; Martinowitz, Uriel
2012-01-01
Glanzmann's thrombasthenia (GT) is characterized by increased bleeding risk. The treatment options in GT are limited. The aim of this study was to test the effect of GT blood supplementation with fibrinogen and factor XIII on thrombin generation, blood clotting, and fibrinolysis. Whole blood samples of GT patients and normal donors treated with eptifibatide (GT model) were subjected to clotting by CaCl(2) and tissue factor. Thrombin generation was measured in platelet-rich plasma. Clot formation and tPA-induced fibrinolysis were evaluated in whole blood by rotation thromboelastometry (ROTEM). Blood was supplemented with fibrinogen (3 g/L) and/or FXIII (2 IU/mL). Thrombin generation analysis of blood derived from GT model and GT patients revealed decreased endogenous thrombin potential and peak height and extended lag time compared to control. However, this method was not sensitive to blood spiking with fibrinogen and FXIII. ROTEM revealed lower maximum clot firmness (MCF) and area under curve (AUC) in the blood of GT model and GT patients. In the absence of exogenous tPA, blood spiking with fibrinogen markedly enhanced clot quality while FXIII had no effect. Combination of fibrinogen and FXIII did not add to the effect of fibrinogen. In contrast, by the addition of tPA, both fibrinogen and FXIII separately and, to more extent, in combination enhanced clot quality as well as resistance against tPA-induced fibrinolysis (increasing MCF, AUC, and lysis onset time). In conclusion, fibrinogen and FXIII exerted stimulation of blood clotting and inhibition of fibrinolysis. Treating normal blood with eptifibatide mimics the changes of coagulopathy in GT blood.
Waveform fitting and geometry analysis for full-waveform lidar feature extraction
NASA Astrophysics Data System (ADS)
Tsai, Fuan; Lai, Jhe-Syuan; Cheng, Yi-Hsiu
2016-10-01
This paper presents a systematic approach that integrates spline curve fitting and geometry analysis to extract full-waveform LiDAR features for land-cover classification. The cubic smoothing spline algorithm is used to fit the waveform curve of the received LiDAR signals. After that, the local peak locations of the waveform curve are detected using a second derivative method. According to the detected local peak locations, commonly used full-waveform features such as full width at half maximum (FWHM) and amplitude can then be obtained. In addition, the number of peaks, time difference between the first and last peaks, and the average amplitude are also considered as features of LiDAR waveforms with multiple returns. Based on the waveform geometry, dynamic time-warping (DTW) is applied to measure the waveform similarity. The sum of the absolute amplitude differences that remain after time-warping can be used as a similarity feature in a classification procedure. An airborne full-waveform LiDAR data set was used to test the performance of the developed feature extraction method for land-cover classification. Experimental results indicate that the developed spline curve- fitting algorithm and geometry analysis can extract helpful full-waveform LiDAR features to produce better land-cover classification than conventional LiDAR data and feature extraction methods. In particular, the multiple-return features and the dynamic time-warping index can improve the classification results significantly.
Mastalerz, Lucyna; Celińska-Lӧwenhoff, Magdalena; Krawiec, Piotr; Batko, Bogdan; Tłustochowicz, Witold; Undas, Anetta
2015-01-01
Given reports on the increased prevalence of thromboembolic incidents in patients with eosinophilic granulomatosis with polyangiitis (EGPA; Churg-Strauss syndrome), we investigated whether fibrin clot properties are unfavorably altered in EGPA. Ex vivo plasma fibrin clot characteristics, including clot permeability, turbidimetry and efficiency of fibrinolysis using two assays, were investigated in 34 consecutive patients with remission in EGPA according to the Birmingham Vasculitis Activity Score version 3 (23 female, 11 male), aged 48 (range, 21-80) years. The control group comprised 34 age- and sex- matched volunteers. Compared with controls, patients with EGPA were characterized by denser fiber clots (estimated pore size, Ks, 7.30±0.93 vs 10.14±1.07 10-9 cm2), faster fibrin polymerization (lag phase in a turbidimetric curve, 41.8±3.6 vs 47.4±2.9 s), thicker fibrin fibers (maximum absorbance, ΔAbs, 0.87±0.09 vs 0.72±0.07), higher maximum levels of D-dimer released from clots (DDmax 4.10±0.46 vs 3.54±0.35 mg/L), and prolonged clot lysis time (t50%; 9.50±1.45 vs 7.56±0.87 min); all p<0.0001. Scanning electron microscopy images confirmed denser plasma fibrin networks composed of thinner fibers formed in EGPA. Antineutrophil cytoplasmic antibody status and C-reactive protein did not affect clot variables. Multivariate analysis adjusted for fibrinogen showed that Ks was predicted by eosinophil count, peak thrombin generation, factor VIII, and soluble CD40 ligand, whereas eosinophil count, peak thrombin generation and antiplasmin predicted t50%. This study is the first to show that EGPA is associated with prothrombotic plasma fibrin clot phenotype, which may contribute to thromboembolic manifestations reported in this disease.
Mastalerz, Lucyna; Celińska-Lӧwenhoff, Magdalena; Krawiec, Piotr; Batko, Bogdan; Tłustochowicz, Witold; Undas, Anetta
2015-01-01
Objectives Given reports on the increased prevalence of thromboembolic incidents in patients with eosinophilic granulomatosis with polyangiitis (EGPA; Churg-Strauss syndrome), we investigated whether fibrin clot properties are unfavorably altered in EGPA. Methods Ex vivo plasma fibrin clot characteristics, including clot permeability, turbidimetry and efficiency of fibrinolysis using two assays, were investigated in 34 consecutive patients with remission in EGPA according to the Birmingham Vasculitis Activity Score version 3 (23 female, 11 male), aged 48 (range, 21–80) years. The control group comprised 34 age- and sex- matched volunteers. Results Compared with controls, patients with EGPA were characterized by denser fiber clots (estimated pore size, Ks, 7.30±0.93 vs 10.14±1.07 10−9 cm2), faster fibrin polymerization (lag phase in a turbidimetric curve, 41.8±3.6 vs 47.4±2.9 s), thicker fibrin fibers (maximum absorbance, ΔAbs, 0.87±0.09 vs 0.72±0.07), higher maximum levels of D-dimer released from clots (DDmax 4.10±0.46 vs 3.54±0.35 mg/L), and prolonged clot lysis time (t50%; 9.50±1.45 vs 7.56±0.87 min); all p<0.0001. Scanning electron microscopy images confirmed denser plasma fibrin networks composed of thinner fibers formed in EGPA. Antineutrophil cytoplasmic antibody status and C-reactive protein did not affect clot variables. Multivariate analysis adjusted for fibrinogen showed that Ks was predicted by eosinophil count, peak thrombin generation, factor VIII, and soluble CD40 ligand, whereas eosinophil count, peak thrombin generation and antiplasmin predicted t50%. Conclusion This study is the first to show that EGPA is associated with prothrombotic plasma fibrin clot phenotype, which may contribute to thromboembolic manifestations reported in this disease. PMID:26540111
Kallmes, David F; Brinjikji, Waleed
2017-01-01
Background Predicting recanalization success for patients undergoing endovascular treatment for acute ischemic stroke is of significant interest. Studies have previously correlated the success of recanalization with the density of the clot. We evaluated clot density and its relationship to revascularization success and stroke etiology. Methods We conducted a retrospective review of 118 patients undergoing intra-arterial therapy for acute ischemic stroke. Mean and maximum thrombus density was measured by drawing a circular region of interest on an axial slice of a non-contrast computed tomography scan. T-tests were used to compare clot density to recanalization success or to stroke etiology, namely large artery atherosclerosis and cardioembolism. Recanalization success was compared in four device groups: aspiration, stent retriever, aspiration and stent retriever, and all other. Results There was no significant difference in the mean clot density in patients with successful (n = 80) versus unsuccessful recanalization (n = 38, 50.1 ± 7.4 Hounsfield unit (HU) vs. 53 ± 12.7 HU; P = 0.17). Comparing the large artery thromboembolism (n = 35) to the cardioembolic etiology group (n = 56), there was no significant difference in mean clot density (51.5 ± 7.7 HU vs. 49.7 ± 8.5 HU; P = 0.31). A subgroup analysis of middle cerebral artery occlusions (n = 65) showed similar, non-statistically significant differences between groups. There was no difference in the rate of recanalization success in patients with a mean clot density greater than 50 HU or less than 50 HU in each of the four device groups. Conclusions There was no relationship between clot density and revascularization success or stroke etiology in our study. More research is needed to determine if clot density can predict recanalization rates or indicate etiology. PMID:28604188
Sapkal, Gajanan N; Wairagkar, Nitin S; Ayachit, Vijay M; Bondre, Vijay P; Gore, Milind M
2007-12-01
Clinical specimens from an encephalitis outbreak in the Lakhimpur area of Uttar Pradesh, India, were investigated for identification and characterization of the etiologic agent. IgM capture ELISA showed recent Japanese encephalitis virus (JEV) infection. JEV isolation was attempted from white blood cells (WBCs) separated from blood clots of 12 patients (9 IgM positive and 3 negative) by serial co-culturing with phytohemagglutinin P-stimulated peripheral blood mononuclear leukocytes (PBMCs) obtained from pre-screened JEV sero-negative healthy individuals. JEV was isolated from two IgM-positive blood clots. Isolate 014178 was detected in WBCs and in the first passage of PBMCs by ELISA and reverse transcriptase-polymerase chain reaction. Isolate 014173 was detectable only after a second passage in PBMC co-culture. Sequence analysis of 346 nt of the C-prM region showed homology with JEV strain GP78. This is the first report on isolation of JEV from patient blood clots. Our study shows that the co-cultures of PBMCs separated from patient blood clots provide an additional source for JEV isolation.
Whole blood clots are more resistant to lysis than plasma clots--greater efficacy of rivaroxaban.
Varin, Rémi; Mirshahi, Shahsultan; Mirshahi, Pezhman; Klein, Christophe; Jamshedov, Jovid; Chidiac, Jean; Perzborn, Elisabeth; Mirshahi, Massoud; Soria, Claudine; Soria, Jeannette
2013-03-01
Defective thrombolysis, a thrombotic risk factor, can be attributed to the formation of a compact clot poorly accessible to fibrinolytic enzymes. Venous thrombi, rich in red blood cells (RBCs), and arterial thrombi containing various amounts of RBCS, plasma and whole blood (WB) clot permeability and degradability were compared. The effect of rivaroxaban, a potent direct factor Xa inhibitor, was also evaluated. Fibrin permeability was determined by flow measurement through the clot. Clot degradability was evaluated by the amount of D-dimer generated by clot perfusion with plasminogen and tissue plasminogen activator. Fibrin clot structure was assessed by confocal microscopy. WB clot permeability (KS) and degradability were 6.7- and 38-fold lower, respectively, compared with plasma clots. This is attributed to 1) occlusion of fibrin pores by RBCs and 2) a consistent increase in thrombin generation due to platelets and RBCs inducing formation of a tighter clot. Rivaroxaban added to plasma or WB before clotting, in reducing thrombin generation, led to the formation of a looser clot that is more degradable by fibrinolytic enzymes. Permeability and degradability of whole blood clots formed in the presence of rivaroxaban were very similar to those of plasma clots. The resistance to fibrinolysis of WB clots was reduced considerably when clots were formed with rivaroxaban. These results may have implications for the development of antithrombotic agents. Copyright © 2012 Elsevier Ltd. All rights reserved.
Hemostatic potential of natural/synthetic polymer based hydrogels crosslinked by gamma radiation
NASA Astrophysics Data System (ADS)
Barba, Bin Jeremiah D.; Tranquilan-Aranilla, Charito; Abad, Lucille V.
2016-01-01
Various raw materials and hydrogels prepared from their combination were assessed for hemostatic capability using swine whole blood clotting analysis. Initial screening showed efficient coagulative properties from κ-carrageenan and its carboxymethylated form, and α-chitosan, even compared to commercial products like QuikClot Zeolite Powder. Blending natural and synthetic polymers formed into hydrogels using gamma radiation produced materials with improved properties. KC and CMKC hydrogels were found to have the lowest blood clotting index in granulated form and had the higher capacity for platelet adhesion in foamed form compared to GelFoam. Possible mechanisms involved in the evident thrombogenicity of the materials include adsorption of platelets and related proteins that aid in platelet activation (primary hemostasis), absorption of water to concentrate protein factors that control the coagulation cascade, contact activation by its negatively charged surface and the formation of gel-blood clots.
Potas, Jason Robert; de Castro, Newton Gonçalves; Maddess, Ted; de Souza, Marcio Nogueira
2015-01-01
Experimental electrophysiological assessment of evoked responses from regenerating nerves is challenging due to the typical complex response of events dispersed over various latencies and poor signal-to-noise ratio. Our objective was to automate the detection of compound action potential events and derive their latencies and magnitudes using a simple cross-correlation template comparison approach. For this, we developed an algorithm called Waveform Similarity Analysis. To test the algorithm, challenging signals were generated in vivo by stimulating sural and sciatic nerves, whilst recording evoked potentials at the sciatic nerve and tibialis anterior muscle, respectively, in animals recovering from sciatic nerve transection. Our template for the algorithm was generated based on responses evoked from the intact side. We also simulated noisy signals and examined the output of the Waveform Similarity Analysis algorithm with imperfect templates. Signals were detected and quantified using Waveform Similarity Analysis, which was compared to event detection, latency and magnitude measurements of the same signals performed by a trained observer, a process we called Trained Eye Analysis. The Waveform Similarity Analysis algorithm could successfully detect and quantify simple or complex responses from nerve and muscle compound action potentials of intact or regenerated nerves. Incorrectly specifying the template outperformed Trained Eye Analysis for predicting signal amplitude, but produced consistent latency errors for the simulated signals examined. Compared to the trained eye, Waveform Similarity Analysis is automatic, objective, does not rely on the observer to identify and/or measure peaks, and can detect small clustered events even when signal-to-noise ratio is poor. Waveform Similarity Analysis provides a simple, reliable and convenient approach to quantify latencies and magnitudes of complex waveforms and therefore serves as a useful tool for studying evoked compound action potentials in neural regeneration studies.
Potas, Jason Robert; de Castro, Newton Gonçalves; Maddess, Ted; de Souza, Marcio Nogueira
2015-01-01
Experimental electrophysiological assessment of evoked responses from regenerating nerves is challenging due to the typical complex response of events dispersed over various latencies and poor signal-to-noise ratio. Our objective was to automate the detection of compound action potential events and derive their latencies and magnitudes using a simple cross-correlation template comparison approach. For this, we developed an algorithm called Waveform Similarity Analysis. To test the algorithm, challenging signals were generated in vivo by stimulating sural and sciatic nerves, whilst recording evoked potentials at the sciatic nerve and tibialis anterior muscle, respectively, in animals recovering from sciatic nerve transection. Our template for the algorithm was generated based on responses evoked from the intact side. We also simulated noisy signals and examined the output of the Waveform Similarity Analysis algorithm with imperfect templates. Signals were detected and quantified using Waveform Similarity Analysis, which was compared to event detection, latency and magnitude measurements of the same signals performed by a trained observer, a process we called Trained Eye Analysis. The Waveform Similarity Analysis algorithm could successfully detect and quantify simple or complex responses from nerve and muscle compound action potentials of intact or regenerated nerves. Incorrectly specifying the template outperformed Trained Eye Analysis for predicting signal amplitude, but produced consistent latency errors for the simulated signals examined. Compared to the trained eye, Waveform Similarity Analysis is automatic, objective, does not rely on the observer to identify and/or measure peaks, and can detect small clustered events even when signal-to-noise ratio is poor. Waveform Similarity Analysis provides a simple, reliable and convenient approach to quantify latencies and magnitudes of complex waveforms and therefore serves as a useful tool for studying evoked compound action potentials in neural regeneration studies. PMID:26325291
Robinson, Ronald A; Herbertson, Luke H; Das, Srilekha Sarkar; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W
2013-01-01
The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body. PMID:23690701
Robinson, Ronald A; Herbertson, Luke H; Sarkar Das, Srilekha; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W
2013-01-01
The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body.
Artificial Stroke Clots: How Wide is the Gap to the Real World?
Berndt, Maria; Prothmann, Sascha; Maegerlein, Christian; Oberdieck, Paul; Zimmer, Claus; Hegge, Barbara; Pelisek, Jaroslav; Schirmer, Lucas; Poppert, Holger; Boeckh-Behrens, Tobias
2018-02-01
Especially since the establishment of mechanical thrombectomy as part of standard stroke therapy, artificial thrombi have become important in the training of interventionalists as well as for the development and testing of devices. So far, these in vitro clots have lacked direct comparisons with ex vivo thrombi. We therefore compared the histologic appearance of dynamically produced clots with that of stroke thrombi acquired during mechanical recanalization. Thrombi of 145 consecutive patients with stroke with large-vessel occlusions were histologically compared with 10 artificial clots, dynamically created from human blood and pig's blood using a Chandler loop system. Quantified FP/RBC ratios (fibrin/platelets divided by red blood cell fraction) and white blood cell (WBC) fractions were identified and compared between artificial (human and pig) and ex vivo thrombi obtained from patients with various stroke causes. There were no significant differences in the analysis of FP/RBC ratios between artificial thrombi and ex vivo thrombi (P = 0.42) or in the more precise analyses considering etiologic subgroups. Distinct differences were observed for the WBC fraction, with lower values in artificial thrombi (median, 1.34%) than in ex vivo thrombi (median, 5%) (P < 0.001). The main clot components, FP and RBC, are presumably the most influential factors for clot stability and mechanical resistance. Similarities between artificially generated and ex vivo stroke clots (and when considering different stroke subgroups) support the usefulness of these artificial thrombi in the pre-evaluation of thrombus extraction devices and as appropriate training material. Copyright © 2017 Elsevier Inc. All rights reserved.
Erber, Matthias; Lee, Geoffrey
2015-09-01
Lyophilized reagents are used on a daily basis in coagulation diagnostics. They often contain a number of excipients in addition to the active compound. Some of these excipients may, however, influence coagulation dynamics. Besides from plasmatic coagulation bulking agents may influence platelet properties. We therefore studied the influence of a variety of bulking agents (glycine, mannitol, sucrose and trehalose) as well as a surfactant (Tween® 80) on whole blood coagulation using thromboelastometry (ROTEM®) and platelet function analysis (ROTEM® platelet). Both disaccharides as well as Tween® 80 did not influence whole blood coagulation in the concentration range investigated. The addition of glycine and mannitol solutions to the ROTEM® measurement leads to an impaired clot formation as well as overall clot strength while clotting initiation remained barely influenced. Hypertonic glycine and mannitol solutions exhibit different clot formation impairment when correlated to their osmolar concentration and compared to equally osmolar NaCl-solutions. The effect of glycine was assigned to fibrin formation impairment identified with the FIBTEM assay. Platelet function analysis revealed that hypertonic glycine solutions do not alter platelet function but hypertonic mannitol and NaCl solutions do. While the influence observed for glycine may be due to fibrinogen precipitation, the mechanism of mannitol appears to be more complex as platelet function as well as fibrin-based clot formation are influenced. This study therefore demonstrates the necessity to check for coagulation impairment due to compounds contained in lyophilized reagents.
Shrimp Alpha-2-Macroglobulin Prevents the Bacterial Escape by Inhibiting Fibrinolysis of Blood Clots
Chaikeeratisak, Vorrapon; Somboonwiwat, Kunlaya; Tassanakajon, Anchalee
2012-01-01
Proteomic analysis of the hemocytic proteins of Penaeus monodon (Pm) has previously shown that alpha-2-macroglobulin (A2M) was among the proteins that showed substantially altered expression levels upon Vibrio harveyi infection. Therefore, in this study its potentially important role in the response of shrimp to bacterial infection was further characterized. The yeast two-hybrid system revealed that the receptor binding domain of PmA2M interacted with the carboxyl-terminus of one or both of the transglutaminase type II isoforms, which are key enzymes involved in the shrimp clotting system. In accord with this, PmA2M was found to be localized on the extracellular blood clots and to colocalize with clottable proteins. RNA interference (RNAi)-mediated knockdown of A2M transcript levels reduced the PmA2M transcript levels (∼94%) and significantly reduced the bacterial seizing ability of the clotting system, resulting in an up to 3.3-fold higher number of V. harveyi that systemically disseminated into the circulatory system at 5 min post-infection before subsequent clearance by the immune system. Furthermore, an appearance of PmA2M depleted clots in the presence of V. harveyi strikingly demonstrated fibrinolysis zones surrounding the bacteria. This study provides the first evidence of the vital role of PmA2M in enhancing bacterial sequestration by protecting blood clots against fibrinolysis. PMID:23082160
Chaikeeratisak, Vorrapon; Somboonwiwat, Kunlaya; Tassanakajon, Anchalee
2012-01-01
Proteomic analysis of the hemocytic proteins of Penaeus monodon (Pm) has previously shown that alpha-2-macroglobulin (A2M) was among the proteins that showed substantially altered expression levels upon Vibrio harveyi infection. Therefore, in this study its potentially important role in the response of shrimp to bacterial infection was further characterized. The yeast two-hybrid system revealed that the receptor binding domain of PmA2M interacted with the carboxyl-terminus of one or both of the transglutaminase type II isoforms, which are key enzymes involved in the shrimp clotting system. In accord with this, PmA2M was found to be localized on the extracellular blood clots and to colocalize with clottable proteins. RNA interference (RNAi)-mediated knockdown of A2M transcript levels reduced the PmA2M transcript levels (∼94%) and significantly reduced the bacterial seizing ability of the clotting system, resulting in an up to 3.3-fold higher number of V. harveyi that systemically disseminated into the circulatory system at 5 min post-infection before subsequent clearance by the immune system. Furthermore, an appearance of PmA2M depleted clots in the presence of V. harveyi strikingly demonstrated fibrinolysis zones surrounding the bacteria. This study provides the first evidence of the vital role of PmA2M in enhancing bacterial sequestration by protecting blood clots against fibrinolysis.
Effect of clot aging and cholesterol content on ultrasound-assisted thrombolysis.
Zhou, Yufeng; Murugappan, Suresh Kanna; Sharma, Vijay Kumar
2014-10-01
Exposure to 2-MHz transcranial diagnostic ultrasound enhances the thrombolytic activity of intravenously administered tissue plasminogen activator (IV-tPA) in acute ischemic stroke (sonothrombolysis). However, rates of arterial recanalization vary widely, depending upon the clot burden, its location, and stroke subtype. We evaluated the influence of age and cholesterol level of the blood clots on sonothrombolysis in an in vitro model. To "age" the clots, serum was replaced by fresh blood periodically. We increased the cholesterol content of the clots by adding cholesterin to the blood. The clots were lysed by tPA and/or transcranial Doppler ultrasound sonication for 1 h. The extent of thrombolysis induced by various treatment protocols (controls, sonication, tPA, and sonothrombolysis) was evaluated with relative changes in the clot weights and in the clot structure by scanning electron microscopy (SEM) at end of the experiment. Sonothrombolysis induced significantly higher weight reduction in fresh clots (37.3 % in 2-h old clots versus 24.8 % in 10-h ones, p < 0.005) as well as the clots with higher cholesterol levels (41.7 versus 30.6 % in normal cholesterol clots, p < 0.005). SEM demonstrated patterns of clot dissolution among various treatment modalities. Sonothrombolysis induced better clot lysis in fresh thrombi with high cholesterol levels.
Effects of calcium binding and of EDTA and CaEDTA on the clotting of bovine fibrinogen by thrombin.
Perizzolo, K E; Sullivan, S; Waugh, D F
1985-03-01
Studies were carried out at pH 7.0 and gamma/2 0.15 before addition of CaCl2 or EDTA. Clotting time, tau, at 3.03 microM fibrinogen and 0.91 u/ml thrombin was determined for equilibrium systems. With added Ca2+, tau decreases, from tau 0 at 0 added Ca2+ (mean, 29.7 +/- 3 s), by approximately 3 s at 5 mM added Ca2+. With added EDTA, tau increases sigmoidally from tau 0 at 0 EDTA to a maximum (mean tau m = 142 +/- 23 s) at approximately 200 microM EDTA. tau then decreases slightly to a minimum at approximately 1.3 mM and finally increases to infinity at approximately 10 mM EDTA. Between 0 and 1.3 mM EDTA, effects on clotting time are completely reversed by adding Ca2+ and, after equilibration at 400 microM EDTA, tau is independent of EDTA concentration. Thus, up to 400 microM EDTA, effects on clotting time are attributed to decreasing fibrinogen bound Ca2+. Between 5 mM Ca2+ and 200 microM EDTA it is assumed that an equilibrium distribution of fibrinogen species having 3, 2, 1, or 0 bound calcium ions is established and that a clotting time is determined by the sum of products of species fractional abundance and pure species clotting time. Analysis indicates that pure species clotting times increase proportionately with decreasing Ca2+ binding, binding sites are nearly independent, and the microscopic association constant for the first bound Ca2+ is approximately 4.9 X 10(6) M-1. Effects of adding Ca2+ at times t1 after thrombin addition to systems initially equilibrated at 200 microM EDTA were determined. Analysis of the relation between tau and t1 indicates that as Ca2+ binding decreases, rate constants for release of B peptides decrease less than those for release of A peptides. As EDTA concentration is increased above 1.3 mM, inhibitory effects of EDTA and CaEDTA progressively increase.
White, Nathan J.; Newton, Jason C.; Martin, Erika J.; Mohammed, Bassem M.; Contaifer, Daniel; Bostic, Jessica L.; Brophy, Gretchen M.; Spiess, Bruce D.; Pusateri, Anthony E.; Ward, Kevin R.; Brophy, Donald F.
2015-01-01
Introduction Anticoagulation, fibrinogen consumption, fibrinolytic activation, and platelet dysfunction all interact to produce different clot formation responses after trauma. However, the relative contributions of these coagulation components to overall clot formation remains poorly defined. We examined for sources of heterogeneity in clot formation responses after trauma. Methods Blood was sampled in the Emergency Department from patients meeting trauma team activation criteria at an urban trauma center. Plasma prothrombin time (PT) ≥ 18 sec was used to define traumatic coagulopathy. Mean kaolin-activated thrombelastography (TEG) parameters were calculated and tested for heterogeneity using Analysis of Means (ANOM). Discriminant analysis and forward stepwise variable selection with linear regression were used to determine if PT, fibrinogen, platelet contractile force (PCF), and D-Dimer concentration, representing key mechanistic components of coagulopathy, each contribute to heterogeneous TEG responses after trauma. Results Of 95 subjects, 16% met criteria for coagulopathy. Coagulopathic subjects were more severely injured with greater shock, and received more blood products in the first 8 hours compared to non-coagulopathic subjects. Mean (SD) TEG maximal amplitude (MA) was significantly decreased in the coagulopathic group=57.5 (4.7) mm, vs. 62.7 (4.7), T test p<0.001. The MA also exceeded the ANOM predicted upper decision limit for the non-coagulopathic group and the lower decision limit for the coagulopathic group at alpha=0.05, suggesting significant heterogeneity from the overall cohort mean. Fibrinogen and PCF best discriminated TEG MA using discriminant analysis. Fibrinogen, PCF, and D-Dimer were primary covariates for TEG MA using regression analysis. Conclusion Heterogeneity in TEG-based clot formation in Emergency Department trauma patients was linked to changes in MA. Individual parameters representing fibrin polymerization, platelet contractile forces, and fibrinolysis were primarily associated with TEG MA after trauma and should be the focus of early hemostatic therapies. PMID:25643013
Ritch, Chad R; Ordonez, Maria A; Okhunov, Zhamshid; Araujo, Juan; Walsh, Rhonda; Baudin, Vania; Lee, Daniel; Badani, Ketan K; Gupta, Mantu; Landman, Jaime
2009-08-01
The management of urinary clot retention and hematuria involves manual irrigation with sterile water or normal saline via a Foley catheter followed by continuous bladder irrigation. Irrigation may become difficult because of the formation of dense blood clots. Tissue plasminogen activator (t-PA/Alteplase) may be a useful pharmacological agent to improve the efficacy of manual irrigation of large, dense clots. The goal of the current study was to compare t-PA to sterile water for clot irrigation in an in vitro model. In vitro models of clot retention were created using 500-cc urinary leg bags each filled with 80 cc of unpreserved whole blood from a healthy volunteer. Each model was incubated at 25 degrees C for 24 hours to allow clot formation. Four models each with 25 mL solution of t-PA at concentrations of 2, 1, 0.5, and 0.25 mg/mL were evaluated and compared to a control (25 mL sterile water). Models were instilled with solution (t-PA or control) and incubated for 30 minutes at 37 degrees C, and then irrigated with sterile water via 18F Foley by a blinded investigator. Three separate experiments were conducted, and statistical analysis was performed comparing various irrigation parameters. Clot evacuation with 25 mL of t-PA at a concentration of 2 mg/mL (50 mg) was significantly easier (p = 0.05) and faster (p < 0.05) than the sterile water control. The mean time for clot evacuation in this model was 2.7 minutes for t-PA solution 2 mg/mL versus 7.3 minutes for the control (p < 0.05). Compared to the control, irrigation with t-PA solution 2 mg/mL also required less irrigant (180 mL vs. 500 mL) (p < 0.05) for complete evacuation. There was a similar trend in efficacy for the lower doses of t-PA, but this was not statistically significant. In this in vitro study, a single 25 mL instillation of t-PA solution 2 mg/mL is significantly better than sterile water alone for clot evacuation. In vivo animal studies are pending.
Photonic microwave waveforms generation based on pulse carving and superposition in time-domain
NASA Astrophysics Data System (ADS)
Xia, Yi; Jiang, Yang; Zi, Yuejiao; He, Yutong; Tian, Jing; Zhang, Xiaoyu; Luo, Hao; Dong, Ruyang
2018-05-01
A novel photonic approach for various microwave waveforms generation based on time-domain synthesis is theoretically analyzed and experimentally investigated. In this scheme, two single-drive Mach-Zehnder modulators are used for pulses shaping. After shifting the phase and implementing envelopes superposition of the pulses, desired waveforms can be achieved in time-domain. The theoretic analysis and simulations are presented. In the experimental demonstrations, a triangular waveform, square waveform, and half duty cycle sawtooth (or reversed-sawtooth) waveform are generated successfully. By utilizing time multiplexing technique, a frequency-doubled sawtooth (or reversed-sawtooth) waveform with 100% duty cycle can be obtained. In addition, a fundamental frequency sawtooth (or reversed-sawtooth) waveform with 100% duty cycle can also be achieved by the superposition of square waveform and frequency-doubled sawtooth waveform.
Combination of ultrasound and rtPA enhances fibrinolysis in an In Vitro clot system
Winter, Philipp; Müller-Werkmeister, Hendrik; Strand, Susanne; König, Jochem; Kempski, Oliver; Ringel, Florian; Kantelhardt, Sven R.; Keric, Naureen
2017-01-01
Background Catheter-based lysis with recombinant tissue plasminogen activator (rtPA) is a well-established therapy for spontaneous intracerebral hemorrhage (ICH). The effectiveness of this therapy can be increased with ultrasound, but the optimal conditions are not yet clearly established. Using a novel in vitro system of blood clots previously developed by our group, we investigated various parameters of intralesional sonothrombolysis using an endosonography catheter in combination with rtPA. Methods Standardized human blood clots were equipped with a drainage catheter and weighed before and after 4 treatments: control (drainage only), rtPA only, ultrasound only and the combination of rtPA+ultrasound. The effectiveness of ultrasound was further analysed in terms of optimal frequency, duration and distance to the probe. Temperature and acoustic peak rarefaction pressure (APRP) were assessed to analyse potential adverse effects and quantify lysis. Histo-morphological analysis of the treated clots was performed by H&E staining and confocal laser scanning microscopy using fluorescent fibrinogen. Results The combined treatment rtPA+ultrasound achieved the highest lysis rates with a relative weight of 30.3%±5.5% (p≤0.0001) compared to all other groups. Similar results were observed when treating aged clots. Confocal fluorescent microscopy of the treated clots revealed a rarefied fibrin mesh without cavitations. No relevant temperature increase occurred (0.53±0.75°C). The optimal insonation treatment time was 1 hour. APRP measurements showed a lysis threshold of 515.5±113.4 kPa. Application of 10 MHz achieved optimal lysis and lysis radius, while simultaneously proving to be the best frequency for morphologic imaging of the clot and surrounding tissue. Conclusions These promising data provide the basis for an individualized minimal invasive ICH therapy by rtPA and sonothrombolysis independent of ICH age. PMID:29145482
Yang, P; Niu, K; Wu, Y; Struffert, T; Doerfler, A; Holter, P; Aagaard-Kienitz, B; Strother, C; Chen, G-H
2017-04-01
The assessment of collaterals and clot burden in patients with acute ischemic stroke provides important information about treatment options and clinical outcome. Time-resolved C-arm conebeam CT angiography has the potential to provide accurate and reliable evaluations of collaterals and clot burden in the angiographic suite. Experience with this technique is extremely limited, and feasibility studies are needed to validate this technique. Our purpose was to present such a feasibility study. Ten C-arm conebeam CT perfusion datasets from 10 subjects with acute ischemic stroke acquired before endovascular treatment were retrospectively processed to generate time-resolved conebeam CTA. From time-resolved conebeam CTA, 2 experienced readers evaluated the clot burden and collateral flow in consensus by using previously reported scoring systems and assessed the clinical value of this novel imaging technique independently. Interobserver agreement was analyzed by using the intraclass correlation analysis method. Clot burden and collateral flow can be assessed by using the commonly accepted scoring systems for all eligible cases. Additional clinical information (eg, the quantitative dynamic information of collateral flow) can be obtained from this new imaging technique. Two readers agreed that time-revolved C-arm conebeam CTA is the preferred method for evaluating the clot burden and collateral flow compared with other conventional imaging methods. Comprehensive evaluations of clot burden and collateral flow are feasible by using time-resolved C-arm conebeam CTA data acquired in the angiography suite. This technique further enriches the imaging tools in the angiography suite to enable a "one-stop- shop" imaging workflow for patients with acute ischemic stroke. © 2017 by American Journal of Neuroradiology.
Chan, Karen Y T; Zhao, Chunyi; Siren, Erika M J; Chan, Jeanne C Y; Boschman, Jeffrey; Kastrup, Christian J
2016-06-13
The adhesion of blood clots to blood vessels, such as through the adhesion of fibrin, is essential in hemostasis. While numerous strategies for initiating clot formation and preventing clot lysis are being developed to create improved hemostatic agents, strategies for enhancing clot adhesion have not been widely explored. Here, we show that adhesion of blood clots can be increased by adding a previously characterized synthetic polymer that is crosslinked by coagulation factor XIIIa during clotting. Addition of the polymer to normal plasma increased the adhesive strength of clots by 2-fold. It also recovered the adhesive strength of nonadhesive fibrinogen-deficient whole blood clots from <0.06 kPa to 1.9 ± 0.14 kPa, which is similar to the adhesive strength of a fibrinogen-rich clot (1.8 ± 0.64 kPa). The polymer also enabled plasma clots to remain adhered under fibrinolytic conditions. By demonstrating that the adhesive strength of clots can be increased with a synthetic material, this provides a potential strategy for creating advanced hemostatic materials, such as treatments for fibrinogen deficiency in trauma-induced coagulopathy.
Computational analysis of blood clot dissolution using a vibrating catheter tip.
Lee, Jeong Hyun; Oh, Jin Sun; Yoon, Bye Ri; Choi, Seung Hong; Rhee, Kyehan; Jho, Jae Young; Han, Moon Hee
2012-04-01
We developed a novel concept of endovascular thrombolysis that employs a vibrating electroactive polymer actuator. In order to predict the efficacy of thrombolysis using the developed vibrating actuator, enzyme (plasminogen activator) perfusion into a clot was analyzed by solving flow fields and species transport equations considering the fluid structure interaction. In vitro thrombolysis experiments were also performed. Computational results showed that plasminogen activator perfusion into a clot was enhanced by actuator vibration at frequencies of 1 and 5 Hz. Plasminogen activator perfusion was affected by the actuator oscillation frequencies and amplitudes that were determined by electromechanical characteristics of a polymer actuator. Computed plasminogen activator perfused volumes were compared with experimentally measured dissolved clot volumes. The computed plasminogen activator perfusion volumes with threshold concentrations of 16% of the initial plasminogen activator concentration agreed well with the in vitro experimental data. This study showed the effectiveness of actuator oscillation on thrombolysis and the validity of the computational plasminogen activator perfusion model for predicting thrombolysis in complex flow fields induced by an oscillating actuator.
1992-05-15
The laboratory heterogeneity of the lupus anticoagulant (LA) was investigated in a multicentre study using a panel of 78 plasma samples diagnosed as containing a LA. Consecutive samples were collected by 12 participants using various screening tests, and sent to 7 laboratories which performed one or more clotting assays among the following: activated partial thromboplastin time (APTT), dilute Russell viper venom time, kaolin clotting time (KCT), dilute tissue thromboplastin time (dTTI) and a platelet neutralization test. For APTT and dTTI, 10 versions of these tests including standard and mixing procedures were carried out. They varied by reagents, phospholipid concentration or methodology. Cut-off times were determined for each test by comparing the results of the panel to those of a control population. When the data of all clotting assays were pooled, 70 of the 78 selected plasmas were considered to contain LA, 15 of them having a low-titer inhibitor. Sensitivity, defined as the proportion of positive results among LA-containing plasmas, varied from 62 to 100% and was positively related to responsiveness (defined as the mean ratio of clotting time to cut-off time). Laboratory heterogeneity of LA-containing plasma was illustrated by a star symbol plot analysis. Different populations of samples, with LA preferentially recognized by one assay (or group of assays) irrespective of the overall sensitivity of this assay, were identified. Multiple component analysis demonstrated the heterogeneity of low-titer inhibitors, which complicates their recognition in routine laboratory investigation.
Comparative lytic efficacy of rt-PA and ultrasound in porcine versus human clots.
Huang, Shenwen; Shekhar, Himanshu; Holland, Christy K
2017-01-01
Porcine thrombi are employed routinely in preclinical models of ischemic stroke. In this study, we examined the differential lytic susceptibility of porcine and human whole blood clots with and without the use of microbubbles and ultrasound (US) as an adjuvant. An in vitro system equipped with time-lapse microscopy was used to evaluate recombinant tissue-plasminogen activator (rt-PA) lysis of porcine and human clots in the same species or cross species plasma. Human and porcine whole blood clots were treated with rt-PA and an echo contrast agent, Definity®, and exposed to intermittent 120 kHz US. The rt-PA lytic efficacy observed for porcine clots in porcine plasma was 22 times lower than for human clots in human plasma reported previously. Further, porcine clots did not exhibit increased lysis with adjuvant Definity® and US exposure. However, the rt-PA lytic susceptibility of the porcine clots in human plasma was similar to that of human clots in human plasma. Human clots perfused with porcine plasma did not respond to rt-PA, but adjuvant use of Definity® and US enhanced lysis. These results reveal considerable differences in lytic susceptibility of porcine clots and human clots to rt-PA. The use of porcine clot models to test new human thrombolytic therapies may necessitate modulation of coagulation and thrombolytic factors to reflect human hemostasis accurately.
Xu, Shixin; Xu, Zhiliang; Kim, Oleg V; Litvinov, Rustem I; Weisel, John W; Alber, Mark
2017-11-01
Thromboembolism, one of the leading causes of morbidity and mortality worldwide, is characterized by formation of obstructive intravascular clots (thrombi) and their mechanical breakage (embolization). A novel two-dimensional multi-phase computational model is introduced that describes active interactions between the main components of the clot, including platelets and fibrin, to study the impact of various physiologically relevant blood shear flow conditions on deformation and embolization of a partially obstructive clot with variable permeability. Simulations provide new insights into mechanisms underlying clot stability and embolization that cannot be studied experimentally at this time. In particular, model simulations, calibrated using experimental intravital imaging of an established arteriolar clot, show that flow-induced changes in size, shape and internal structure of the clot are largely determined by two shear-dependent mechanisms: reversible attachment of platelets to the exterior of the clot and removal of large clot pieces. Model simulations predict that blood clots with higher permeability are more prone to embolization with enhanced disintegration under increasing shear rate. In contrast, less permeable clots are more resistant to rupture due to shear rate-dependent clot stiffening originating from enhanced platelet adhesion and aggregation. These results can be used in future to predict risk of thromboembolism based on the data about composition, permeability and deformability of a clot under specific local haemodynamic conditions. © 2017 The Author(s).
Hickerson, William L; Nur, Israel; Meidler, Roberto
2011-01-01
The objective of the present study was to compare the mechanical, kinetic, and biochemical properties of fibrin clots produced using EVICEL Fibrin Sealant (Human) and TISSEEL Fibrin Sealant. The stiffness/elasticity and strength of fibrin clots formed with EVICEL and TISSEEL were assessed using applied mechanical force and thromboelastography (TEG). The factor XIII content of the fibrin clots was also evaluated. Mean Young modulus and tensile strength of the fibrin clots produced by EVICEL were significantly higher than those of clots produced by TISSEEL (P < 0.05 for both). The mean time to initial clot formation and mean time to the predefined level of clot formation were numerically shorter for EVICEL compared with TISSEEL. Furthermore, mean maximal amplitude of the clots formed with EVICEL was significantly greater than that for the clots formed with TISSEEL. Mean concentration of factor XIII for the EVICEL fibrinogen samples tested was 9 IU/ml compared with undetectable concentrations of factor XIII for the TISSEEL fibrinogen samples. Fibrin clots formed with EVICEL have a much higher resistance to stretching and tensile strength and are more capable of maintaining their structure against applied force than those formed with TISSEEL. EVICEL also allows more rapid development of fibrin clots than TISSEEL. This superior clot strength and resilience obtained with EVICEL relative to TISSEEL may be due in large part to the presence of factor XIII.
Byrnes, James R; Duval, Cédric; Wang, Yiming; Hansen, Caroline E; Ahn, Byungwook; Mooberry, Micah J; Clark, Martha A; Johnsen, Jill M; Lord, Susan T; Lam, Wilbur A; Meijers, Joost C M; Ni, Heyu; Ariëns, Robert A S; Wolberg, Alisa S
2015-10-15
Factor XIII(a) [FXIII(a)] stabilizes clots and increases resistance to fibrinolysis and mechanical disruption. FXIIIa also mediates red blood cell (RBC) retention in contracting clots and determines venous thrombus size, suggesting FXIII(a) is a potential target for reducing thrombosis. However, the mechanism by which FXIIIa retains RBCs in clots is unknown. We determined the effect of FXIII(a) on human and murine clot weight and composition. Real-time microscopy revealed extensive RBC loss from clots formed in the absence of FXIIIa activity, and RBCs exhibited transient deformation as they exited the clots. Fibrin band-shift assays and flow cytometry did not reveal crosslinking of fibrin or FXIIIa substrates to RBCs, suggesting FXIIIa does not crosslink RBCs directly to the clot. RBCs were retained in clots from mice deficient in α2-antiplasmin, thrombin-activatable fibrinolysis inhibitor, or fibronectin, indicating RBC retention does not depend on these FXIIIa substrates. RBC retention in clots was positively correlated with fibrin network density; however, FXIIIa inhibition reduced RBC retention at all network densities. FXIIIa inhibition reduced RBC retention in clots formed with fibrinogen that lacks γ-chain crosslinking sites, but not in clots that lack α-chain crosslinking sites. Moreover, FXIIIa inhibitor concentrations that primarily block α-, but not γ-, chain crosslinking decreased RBC retention in clots. These data indicate FXIIIa-dependent retention of RBCs in clots is mediated by fibrin α-chain crosslinking. These findings expose a newly recognized, essential role for fibrin crosslinking during whole blood clot formation and consolidation and establish FXIIIa activity as a key determinant of thrombus composition and size. © 2015 by The American Society of Hematology.
Shin, Jong Wook; Jeong, Hye Seon; Kwon, Hyon-Jo; Song, Kyu Sang; Kim, Jei
2018-01-01
We evaluated the composition of individual clots retrieved during intra-arterial thrombectomy in relation to recanalization success, stroke subtype, and the presence of clot signs on initial brain images. We analyzed clot and interventional data from 145 retrieval trials performed for 37 patients (69.5±14.0 years, 20 men, large artery atherosclerosis, n = 7; cardioembolism, n = 22; undetermined etiology, n = 8) who had undergone intra-arterial thrombectomy. Rates of clot retrieval and successful recanalization (Arterial Occlusive Lesion score of 2-3) for separate retrieval trials were evaluated. The area occupied by red blood cell (RBC), fibrin/platelets, and white blood cell (WBC) was measured from digitized images of hematoxylin-eosin stained clots. Compositional differences were compared according to recanalization success, stroke subtype, and the presence of hyperdense clot sign on initial computed tomography and/or blooming artifact on magnetic resonance image. Of the 145 total retrieval trials (3.4±2.4 times per patient), clot was retrieved in 93 trials (64%), while recanalization was successful in 73 (50%). Fibrin/platelets (63%) occupied the greatest area in retrieved clots, followed by RBCs (33%) and WBCs (4%). Clots retrieved from successful recanalization exhibited higher RBC composition (37%) than those retrieved from non-recanalization trials (20%, p = 0.001). RBC composition was higher in cardioembolic stroke (38%) rather than large artery atherosclerosis (23%) and undetermined etiology (26%, p = 0.01). Clots exhibiting clot signs (40%) had higher RBC composition than those without clot signs (19%, p = 0.001). RBC-rich clots were associated with successful recanalization of intra-arterial thrombectomy, cardioembolic stroke, and the presence of clot-signs on initial brain images.
Byrnes, James R.; Duval, Cédric; Wang, Yiming; Hansen, Caroline E.; Ahn, Byungwook; Mooberry, Micah J.; Clark, Martha A.; Johnsen, Jill M.; Lord, Susan T.; Lam, Wilbur A.; Meijers, Joost C. M.; Ni, Heyu; Ariëns, Robert A. S.
2015-01-01
Factor XIII(a) [FXIII(a)] stabilizes clots and increases resistance to fibrinolysis and mechanical disruption. FXIIIa also mediates red blood cell (RBC) retention in contracting clots and determines venous thrombus size, suggesting FXIII(a) is a potential target for reducing thrombosis. However, the mechanism by which FXIIIa retains RBCs in clots is unknown. We determined the effect of FXIII(a) on human and murine clot weight and composition. Real-time microscopy revealed extensive RBC loss from clots formed in the absence of FXIIIa activity, and RBCs exhibited transient deformation as they exited the clots. Fibrin band-shift assays and flow cytometry did not reveal crosslinking of fibrin or FXIIIa substrates to RBCs, suggesting FXIIIa does not crosslink RBCs directly to the clot. RBCs were retained in clots from mice deficient in α2-antiplasmin, thrombin-activatable fibrinolysis inhibitor, or fibronectin, indicating RBC retention does not depend on these FXIIIa substrates. RBC retention in clots was positively correlated with fibrin network density; however, FXIIIa inhibition reduced RBC retention at all network densities. FXIIIa inhibition reduced RBC retention in clots formed with fibrinogen that lacks γ-chain crosslinking sites, but not in clots that lack α-chain crosslinking sites. Moreover, FXIIIa inhibitor concentrations that primarily block α-, but not γ-, chain crosslinking decreased RBC retention in clots. These data indicate FXIIIa-dependent retention of RBCs in clots is mediated by fibrin α-chain crosslinking. These findings expose a newly recognized, essential role for fibrin crosslinking during whole blood clot formation and consolidation and establish FXIIIa activity as a key determinant of thrombus composition and size. PMID:26324704
Shin, Jong Wook; Jeong, Hye Seon; Kwon, Hyon-Jo; Song, Kyu Sang
2018-01-01
We evaluated the composition of individual clots retrieved during intra-arterial thrombectomy in relation to recanalization success, stroke subtype, and the presence of clot signs on initial brain images. We analyzed clot and interventional data from 145 retrieval trials performed for 37 patients (69.5±14.0 years, 20 men, large artery atherosclerosis, n = 7; cardioembolism, n = 22; undetermined etiology, n = 8) who had undergone intra-arterial thrombectomy. Rates of clot retrieval and successful recanalization (Arterial Occlusive Lesion score of 2–3) for separate retrieval trials were evaluated. The area occupied by red blood cell (RBC), fibrin/platelets, and white blood cell (WBC) was measured from digitized images of hematoxylin-eosin stained clots. Compositional differences were compared according to recanalization success, stroke subtype, and the presence of hyperdense clot sign on initial computed tomography and/or blooming artifact on magnetic resonance image. Of the 145 total retrieval trials (3.4±2.4 times per patient), clot was retrieved in 93 trials (64%), while recanalization was successful in 73 (50%). Fibrin/platelets (63%) occupied the greatest area in retrieved clots, followed by RBCs (33%) and WBCs (4%). Clots retrieved from successful recanalization exhibited higher RBC composition (37%) than those retrieved from non-recanalization trials (20%, p = 0.001). RBC composition was higher in cardioembolic stroke (38%) rather than large artery atherosclerosis (23%) and undetermined etiology (26%, p = 0.01). Clots exhibiting clot signs (40%) had higher RBC composition than those without clot signs (19%, p = 0.001). RBC-rich clots were associated with successful recanalization of intra-arterial thrombectomy, cardioembolic stroke, and the presence of clot-signs on initial brain images. PMID:29782513
Formation of blood clot on biomaterial implants influences bone healing.
Shiu, Hoi Ting; Goss, Ben; Lutton, Cameron; Crawford, Ross; Xiao, Yin
2014-12-01
The first step in bone healing is forming a blood clot at injured bones. During bone implantation, biomaterials unavoidably come into direct contact with blood, leading to a blood clot formation on its surface prior to bone regeneration. Despite both situations being similar in forming a blood clot at the defect site, most research in bone tissue engineering virtually ignores the important role of a blood clot in supporting healing. Dental implantology has long demonstrated that the fibrin structure and cellular content of a peri-implant clot can greatly affect osteoconduction and de novo bone formation on implant surfaces. This article reviews the formation of a blood clot during bone healing in relation to the use of platelet-rich plasma (PRP) gels. It is implicated that PRP gels are dramatically altered from a normal clot in healing, resulting in conflicting effect on bone regeneration. These results indicate that the effect of clots on bone regeneration depends on how the clots are formed. Factors that influence blood clot structure and properties in relation to bone healing are also highlighted. Such knowledge is essential for developing strategies to optimally control blood clot formation, which ultimately alter the healing microenvironment of bone. Of particular interest are modification of surface chemistry of biomaterials, which displays functional groups at varied composition for the purpose of tailoring blood coagulation activation, resultant clot fibrin architecture, rigidity, susceptibility to lysis, and growth factor release. This opens new scope of in situ blood clot modification as a promising approach in accelerating and controlling bone regeneration.
Comparative lytic efficacy of rt-PA and ultrasound in porcine versus human clots
Shekhar, Himanshu; Holland, Christy K.
2017-01-01
Introduction Porcine thrombi are employed routinely in preclinical models of ischemic stroke. In this study, we examined the differential lytic susceptibility of porcine and human whole blood clots with and without the use of microbubbles and ultrasound (US) as an adjuvant. Materials and methods An in vitro system equipped with time-lapse microscopy was used to evaluate recombinant tissue-plasminogen activator (rt-PA) lysis of porcine and human clots in the same species or cross species plasma. Human and porcine whole blood clots were treated with rt-PA and an echo contrast agent, Definity®, and exposed to intermittent 120 kHz US. Results and conclusions The rt-PA lytic efficacy observed for porcine clots in porcine plasma was 22 times lower than for human clots in human plasma reported previously. Further, porcine clots did not exhibit increased lysis with adjuvant Definity® and US exposure. However, the rt-PA lytic susceptibility of the porcine clots in human plasma was similar to that of human clots in human plasma. Human clots perfused with porcine plasma did not respond to rt-PA, but adjuvant use of Definity® and US enhanced lysis. These results reveal considerable differences in lytic susceptibility of porcine clots and human clots to rt-PA. The use of porcine clot models to test new human thrombolytic therapies may necessitate modulation of coagulation and thrombolytic factors to reflect human hemostasis accurately. PMID:28545055
Capture of lipopolysaccharide (endotoxin) by the blood clot: a comparative study.
Armstrong, Margaret T; Rickles, Frederick R; Armstrong, Peter B
2013-01-01
In vertebrates and arthropods, blood clotting involves the establishment of a plug of aggregated thrombocytes (the cellular clot) and an extracellular fibrillar clot formed by the polymerization of the structural protein of the clot, which is fibrin in mammals, plasma lipoprotein in crustaceans, and coagulin in the horseshoe crab, Limulus polyphemus. Both elements of the clot function to staunch bleeding. Additionally, the extracellular clot functions as an agent of the innate immune system by providing a passive anti-microbial barrier and microbial entrapment device, which functions directly at the site of wounds to the integument. Here we show that, in addition to these passive functions in immunity, the plasma lipoprotein clot of lobster, the coagulin clot of Limulus, and both the platelet thrombus and the fibrin clot of mammals (human, mouse) operate to capture lipopolysaccharide (LPS, endotoxin). The lipid A core of LPS is the principal agent of gram-negative septicemia, which is responsible for more than 100,000 human deaths annually in the United States and is similarly toxic to arthropods. Quantification using the Limulus Amebocyte Lysate (LAL) test shows that clots capture significant quantities of LPS and fluorescent-labeled LPS can be seen by microscopy to decorate the clot fibrils. Thrombi generated in the living mouse accumulate LPS in vivo. It is suggested that capture of LPS released from gram-negative bacteria entrapped by the blood clot operates to protect against the disease that might be caused by its systemic dispersal.
The effective control of a bleeding injury using a medical adhesive containing batroxobin.
You, Kyung Eun; Koo, Min-Ah; Lee, Dae-Hyung; Kwon, Byeong-Ju; Lee, Mi Hee; Hyon, Suong-Hyu; Seomun, Young; Kim, Jong-Tak; Park, Jong-Chul
2014-04-01
Many types of hemostatic agents have been studied for the effective control of bleeding. In this study, a powdery medical adhesive composed of aldehyded dextran and ε-poly (L-lysine) was used with the recombinant batroxobin. Batroxobin is a venomous component from the snake Bothrops atrox moojeni and catalyzes fibrinogen conversion to form soluble fibrin clots. This research aims to examine the performance of the batroxobin-containing adhesive for hemostasis, and evaluate its potential as a novel hemostatic adhesive. The fibrinogen conversion ability of batroxobin was evaluated by a fibrinogen clotting assay and a whole blood clotting assay. Both experiments demonstrated the effectiveness of the batroxobin-containing adhesive for blood clot formation. Animal experiments were also conducted. After a pricking wound was made in an ICR (imprinting control region) mouse liver, the adhesive and various concentrations of batroxobin were applied. The total amount of blood loss was reduced with increasing concentrations of batroxobin. For excessive bleeding conditions, the femoral artery wound model of SD (Sprague-Dawley) rats was adopted. With higher concentrations of batroxobin, hemostasis was more rapidly achieved. Histological analysis of the liver model also supports the hemostatic effects through fibrin clot formation. In conclusion, batroxobin and medical adhesive effectively facilitate blood coagulation, and could be developed for clinical use.
Adaptive phase k-means algorithm for waveform classification
NASA Astrophysics Data System (ADS)
Song, Chengyun; Liu, Zhining; Wang, Yaojun; Xu, Feng; Li, Xingming; Hu, Guangmin
2018-01-01
Waveform classification is a powerful technique for seismic facies analysis that describes the heterogeneity and compartments within a reservoir. Horizon interpretation is a critical step in waveform classification. However, the horizon often produces inconsistent waveform phase, and thus results in an unsatisfied classification. To alleviate this problem, an adaptive phase waveform classification method called the adaptive phase k-means is introduced in this paper. Our method improves the traditional k-means algorithm using an adaptive phase distance for waveform similarity measure. The proposed distance is a measure with variable phases as it moves from sample to sample along the traces. Model traces are also updated with the best phase interference in the iterative process. Therefore, our method is robust to phase variations caused by the interpretation horizon. We tested the effectiveness of our algorithm by applying it to synthetic and real data. The satisfactory results reveal that the proposed method tolerates certain waveform phase variation and is a good tool for seismic facies analysis.
Hoemann, Caroline D; Marchand, Catherine; Rivard, Georges-Etienne; El-Gabalawy, Hani; Poubelle, Patrice E
2017-11-01
Controlling the blood clot phenotype in a surgically prepared wound is an evolving concept in scaffold-guided tissue engineering. Here, we investigated the effect of added chitosan (80% or 95% Degree of Deacetylation, DDA) or coagulation factors (recombinant human Factor VIIa, Tissue Factor, thrombin) on inflammatory factors released by blood clots. We tested the hypothesis that 80% DDA chitosan specifically enhances leukotriene B 4 (LTB 4 ) production. Human or rabbit whole blood was combined with isotonic chitosan solutions, coagulation factors, or lipopolysaccharide, cultured in vitro at 37°C, and after 4hours the serum was assayed for LTB 4 or inflammatory factors. Only 80% DDA chitosan clots produced around 15-fold more LTB 4 over other clots including 95% DDA chitosan clots. All serum contained high levels of PDGF-BB and CXCL8. Normal clots produced very low type I cytokines compared to lipopolysaccharide clots, with even lower IL-6 and IL-12 and more CCL3/CCL4 produced by chitosan clots. Coagulation factors had no detectable effect on clot phenotype. Conclusion In blood clots from healthy individuals, 80% DDA chitosan has a unique influence of inducing more LTB 4 , a potent neutrophil chemoattractant, with similar production of PDGF-BB and CXCL8, and lower type I cytokines, compared to whole blood clots. Copyright © 2017 Elsevier B.V. All rights reserved.
Dibiasi, Christoph; Plewka, Jacek; Ploszczanski, Leon; Glanz, Veronika; Lichtenegger, Helga; Windberger, Ursula
2018-04-14
Although the coagulation system is evolutionary well preserved, profound species differences exist in viscoelastic as well as in common laboratory tests of coagulation. Evaluating differences in clot formation and material characterisation of clots of four mammalian species on macro-, micro- and nanoscales by the means of rheometry, scanning electron microscopy (SEM) and small angle x-ray scattering (SAXS). Blood samples were collected from healthy human volunteers, laboratory rats (HL/LE inbred strain), warmblood horses and dromedary camels. Clot formation was observed by oscillating shear rheometry until plateau formation of the shear storage modulus G', at which point selected clots were prepared for scanning electron microscopy. SEM images were analysed for fibre diameter and fractal dimension. Additionally, scattering profiles for plasma and whole blood samples were obtained with SAXS. Viscoelasticity of clots showed great interspecies variation: clots of rats and horses exhibited shorter clotting times and higher G' plateau values, when compared to human clots. Camel clots showed unique clotting characteristics with no G' plateau formation in the timeframe observed. Less differentiating features were found with SEM and SAXS, although the rat fibre network appears to be more convoluted and dense, which resulted in a higher fractal dimension. Clotting kinetic differs between the species, which is not only of clinical interest, but could also be an important finding for animal models of blood coagulation.
NASA Astrophysics Data System (ADS)
Hinder, Ian; Buonanno, Alessandra; Boyle, Michael; Etienne, Zachariah B.; Healy, James; Johnson-McDaniel, Nathan K.; Nagar, Alessandro; Nakano, Hiroyuki; Pan, Yi; Pfeiffer, Harald P.; Pürrer, Michael; Reisswig, Christian; Scheel, Mark A.; Schnetter, Erik; Sperhake, Ulrich; Szilágyi, Bela; Tichy, Wolfgang; Wardell, Barry; Zenginoğlu, Anıl; Alic, Daniela; Bernuzzi, Sebastiano; Bode, Tanja; Brügmann, Bernd; Buchman, Luisa T.; Campanelli, Manuela; Chu, Tony; Damour, Thibault; Grigsby, Jason D.; Hannam, Mark; Haas, Roland; Hemberger, Daniel A.; Husa, Sascha; Kidder, Lawrence E.; Laguna, Pablo; London, Lionel; Lovelace, Geoffrey; Lousto, Carlos O.; Marronetti, Pedro; Matzner, Richard A.; Mösta, Philipp; Mroué, Abdul; Müller, Doreen; Mundim, Bruno C.; Nerozzi, Andrea; Paschalidis, Vasileios; Pollney, Denis; Reifenberger, George; Rezzolla, Luciano; Shapiro, Stuart L.; Shoemaker, Deirdre; Taracchini, Andrea; Taylor, Nicholas W.; Teukolsky, Saul A.; Thierfelder, Marcus; Witek, Helvi; Zlochower, Yosef
2013-01-01
The Numerical-Relativity-Analytical-Relativity (NRAR) collaboration is a joint effort between members of the numerical relativity, analytical relativity and gravitational-wave data analysis communities. The goal of the NRAR collaboration is to produce numerical-relativity simulations of compact binaries and use them to develop accurate analytical templates for the LIGO/Virgo Collaboration to use in detecting gravitational-wave signals and extracting astrophysical information from them. We describe the results of the first stage of the NRAR project, which focused on producing an initial set of numerical waveforms from binary black holes with moderate mass ratios and spins, as well as one non-spinning binary configuration which has a mass ratio of 10. All of the numerical waveforms are analysed in a uniform and consistent manner, with numerical errors evaluated using an analysis code created by members of the NRAR collaboration. We compare previously-calibrated, non-precessing analytical waveforms, notably the effective-one-body (EOB) and phenomenological template families, to the newly-produced numerical waveforms. We find that when the binary's total mass is ˜100-200M⊙, current EOB and phenomenological models of spinning, non-precessing binary waveforms have overlaps above 99% (for advanced LIGO) with all of the non-precessing-binary numerical waveforms with mass ratios ⩽4, when maximizing over binary parameters. This implies that the loss of event rate due to modelling error is below 3%. Moreover, the non-spinning EOB waveforms previously calibrated to five non-spinning waveforms with mass ratio smaller than 6 have overlaps above 99.7% with the numerical waveform with a mass ratio of 10, without even maximizing on the binary parameters.
... have hemophilia, you have little or no clotting factor. Clotting factor is a protein needed for normal blood clotting. ... The main treatment is injecting the missing clotting factor into the bloodstream. You may need it on ...
Haworth, Kevin J; Weidner, Christopher R; Abruzzo, Todd A; Shearn, Jason T; Holland, Christy K
2015-01-01
Background Although coil embolization is known to prevent rebleeding from acutely ruptured cerebral aneurysms, the underlying biological and mechanical mechanisms have not been characterized. We sought to determine if microcoil-dependent interactions with thrombus induce structural and mechanical changes in the adjacent fibrin network. Such changes could play an important role in the prevention of aneurysm rebleeding. Methods The stiffness of in vitro human blood clots and coil–clot complexes implanted into aneurysm phantoms were measured immediately after formation and after retraction for 3 days using unconfined uniaxial compression assays. Scanning electron microscopy of the coil–clot complexes showed the effect of coiling on clot structure. Results The coil packing densities achieved were in the range of clinical practice. Bare platinum coils increased clot stiffness relative to clot alone (Young’s modulus 6.9 kPa and 0.83 kPa, respectively) but did not affect fibrin structure. Hydrogel-coated coils prevented formation of a clot and had no significant effect on clot stiffness (Young’s modulus 2 kPa) relative to clot alone. Clot age decreased fiber density by 0.2 fibers/µm2 but not the stiffness of the bare platinum coil–clot complex. Conclusions The stiffness of coil–clot complexes is related to the summative stiffness of the fibrin network and associated microcoils. Hydrogel-coated coils exhibit significantly less stiffness due to the mechanical properties of the hydrogel and the inhibition of fibrin network formation by the hydrogel. These findings have important implications for the design and engineering of aneurysm occlusion devices. PMID:24668257
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wackerbarth, David
Sandia National Laboratories has developed a computer program to review, reduce and manipulate waveform data. PlotData is designed for post-acquisition waveform data analysis. PlotData is both a post-acquisition and an advanced interactive data analysis environment. PlotData requires unidirectional waveform data with both uniform and discrete time-series measurements. PlotData operates on a National Instruments' LabVIEW™ software platform. Using PlotData, the user can capture waveform data from digitizing oscilloscopes over a GPIB, USB and Ethernet interface from Tektronix, Lecroy or Agilent scopes. PlotData can both import and export several types of binary waveform files including, but not limited to, Tektronix .wmf files,more » Lecroy.trc files and xy pair ASCIIfiles. Waveform manipulation includes numerous math functions, integration, differentiation, smoothing, truncation, and other specialized data reduction routines such as VISAR, POV, PVDF (Bauer) piezoelectric gauges, and piezoresistive gauges such as carbon manganin pressure gauges.« less
Freese, John P; Jorgenson, Dawn B; Liu, Ping-Yu; Innes, Jennifer; Matallana, Luis; Nammi, Krishnakant; Donohoe, Rachael T; Whitbread, Mark; Silverman, Robert A; Prezant, David J
2013-08-27
Ventricular fibrillation (VF) waveform properties have been shown to predict defibrillation success and outcomes among patients treated with immediate defibrillation. We postulated that a waveform analysis algorithm could be used to identify VF unlikely to respond to immediate defibrillation, allowing selective initial treatment with cardiopulmonary resuscitation in an effort to improve overall survival. In a multicenter, double-blind, randomized study, out-of-hospital cardiac arrest patients in 2 urban emergency medical services systems were treated with automated external defibrillators using either a VF waveform analysis algorithm or the standard shock-first protocol. The VF waveform analysis used a predefined threshold value below which return of spontaneous circulation (ROSC) was unlikely with immediate defibrillation, allowing selective treatment with a 2-minute interval of cardiopulmonary resuscitation before initial defibrillation. The primary end point was survival to hospital discharge. Secondary end points included ROSC, sustained ROSC, and survival to hospital admission. Of 6738 patients enrolled, 987 patients with VF of primary cardiac origin were included in the primary analysis. No immediate or long-term survival benefit was noted for either treatment algorithm (ROSC, 42.5% versus 41.2%, P=0.70; sustained ROSC, 32.4% versus 33.4%, P=0.79; survival to admission, 34.1% versus 36.4%, P=0.46; survival to hospital discharge, 15.6% versus 17.2%, P=0.55, respectively). Use of a waveform analysis algorithm to guide the initial treatment of out-of-hospital cardiac arrest patients presenting in VF did not improve overall survival compared with a standard shock-first protocol. Further study is recommended to examine the role of waveform analysis for the guided management of VF.
Interactions between individual ultrasound-stimulated microbubbles and fibrin clots.
Acconcia, Christopher; Leung, Ben Y C; Manjunath, Anoop; Goertz, David E
2014-09-01
The use of ultrasound-stimulated microbubbles (USMBs) to promote thrombolysis is well established, but there remains considerable uncertainty about the mechanisms of this process. Here we examine the microscale interactions between individual USMBs and fibrin clots as a function of bubble size, exposure conditions and clot type. Microbubbles (n = 185) were placed adjacent to clot boundaries ("coarse" or "fine") using optical tweezers and exposed to 1-MHz ultrasound as a function of pressure (0.1-0.39 MPa). High-speed (10 kfps) imaging was employed, and clots were subsequently assessed with 2-photon microscopy. For fine clots, 46% of bubbles "embedded" within 10 μm of the clot boundary at pressures of 0.1 and 0.2 MPa, whereas at 0.39 MPa, 53% of bubbles penetrated and transited into the clots with an incidence inversely related to their diameter. A substantial fraction of penetrating bubbles induced fibrin network damage and promoted the uptake of nanobeads. In coarse clots, penetration occurred more readily and at lower pressures than in fine clots. The results therefore provide direct evidence of therapeutically relevant effects of USMBs and indicate their dependence on size, exposure conditions and clot properties. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
... if you get hurt, your body forms a blood clot to stop the bleeding. After the bleeding stops ... some people get too many clots or their blood clots abnormally. Many conditions can cause the blood to ...
NASA Astrophysics Data System (ADS)
Soares, Luiz Guilherme P.; Aciole, Jouber Mateus d. S.; Neves, Bruno Luiz R. C.; Silveira, Landulfo; Pinheiro, Antônio L. B.
2015-03-01
Phototherapies have shown positive effects on the bone repair process, increasing the blood supply to the injured area. The aim of this study was to assess through Raman spectroscopy, the efficacy of laser phototherapy (λ = 780 nm, P = 70 mW, CW, 20.4 J/cm2 per session, 163.2 J/cm2 per treatment) on the bone repair process of osteoporotic rats. The osteoporosis induction was achieved by ovariectomy surgery. Thirty Wistar rats were divided into 4 groups (Basal; OVX, OVX + Clot and OVX + Clot + Laser), then subdivided into 2 subgroups according to the experimental time (15 and 30 days). After the osteoporosis induction time (60 days), a bone defect with 2 mm was created with a trephine drill in the right femur in the animals of groups OVX, Clot and Clot + Laser. After surgery, the irradiation protocol was applied in the same groups on repeated sessions every 48 hours during 15 days. The samples were analyzed by Raman Spectroscopy to assess the inorganic content of phosphate and carbonated hydroxyapatite (~960 and 1070 cm-1, respectively) and organic lipids and proteins (~1454 cm-1). Statistical analysis (ANOVA, Student-T test) showed significant difference between groups Basal, OVX + Clot, and OVX + Clot + Laser for the inorganic content peaks at ~960 (p≤0.001), and ~1070 cm-1 (p≤0.001) in both periods of 15 and 30 days, however on peak at ~1450 cm-1 no differences were detected. It was concluded that the Laser phototherapy increased deposition of HA on bone repair process of osteoporotic rats.
Genetics Home Reference: warfarin sensitivity
... it thins the blood, preventing blood clots from forming . Warfarin is often prescribed to prevent blood clots ... much drug to prevent clots because their clot forming process is already slower than average and can ...
High-speed shaking of frozen blood clots for extraction of human and malaria parasite DNA.
Lundblom, Klara; Macharia, Alex; Lebbad, Marianne; Mohammed, Adan; Färnert, Anna
2011-08-08
Frozen blood clots remaining after serum collection is an often disregarded source of host and pathogen DNA due to troublesome handling and suboptimal outcome. High-speed shaking of clot samples in a cell disruptor manufactured for homogenization of tissue and faecal specimens was evaluated for processing frozen blood clots for DNA extraction. The method was compared to two commercial clot protocols based on a chemical kit and centrifugation through a plastic sieve, followed by the same DNA extraction protocol. Blood clots with different levels of parasitaemia (1-1,000 p/μl) were prepared from parasite cultures to assess sensitivity of PCR detection. In addition, clots retrieved from serum samples collected within two epidemiological studies in Kenya (n = 630) were processed by high speed shaking and analysed by PCR for detection of malaria parasites and the human α-thalassaemia gene. High speed shaking succeeded in fully dispersing the clots and the method generated the highest DNA yield. The level of PCR detection of P. falciparum parasites and the human thalassaemia gene was the same as samples optimally collected with an anticoagulant. The commercial clot protocol and centrifugation through a sieve failed to fully dissolve the clots and resulted in lower sensitivity of PCR detection. High speed shaking was a simple and efficacious method for homogenizing frozen blood clots before DNA purification and resulted in PCR templates of high quality both from humans and malaria parasites. This novel method enables genetic studies from stored blood clots.
Contraction of Blood Clots Is Impaired in Acute Ischemic Stroke.
Tutwiler, Valerie; Peshkova, Alina D; Andrianova, Izabella A; Khasanova, Dina R; Weisel, John W; Litvinov, Rustem I
2017-02-01
Obstructive thrombi or thrombotic emboli are the pathogenic basis of ischemic stroke. In vitro blood clots and in vivo thrombi can undergo platelet-driven contraction (retraction), resulting in volume shrinkage. Clot contraction can potentially reduce vessel occlusion and improve blood flow past emboli or thrombi. The aim of this work was to examine a potential pathogenic role of clot contraction in ischemic stroke. We used a novel automated method that enabled us to quantify time of initiation and extent and rate of clot contraction in vitro. The main finding is that clot contraction from the blood of stroke patients was reduced compared with healthy subjects. Reduced clot contraction correlated with a lower platelet count and their dysfunction, higher levels of fibrinogen and hematocrit, leukocytosis, and other changes in blood composition that may affect platelet function and properties of blood clots. Platelets from stroke patents were spontaneously activated and displayed reduced responsiveness to additional stimulation. Clinical correlations with respect to severity and stroke pathogenesis suggest that the impaired clot contraction has the potential to be a pathogenic factor in ischemic stroke. The changeable ability of clots and thrombi to shrink in volume may be a novel unappreciated mechanism that aggravates or alleviates the course and outcomes of ischemic stroke. The clinical importance of clot or thrombus transformations in vivo and the diagnostic and prognostic value of this blood test for clot contraction need further exploration. © 2016 American Heart Association, Inc.
Contraction of Blood Clots is Impaired in Acute Ischemic Stroke
Tutwiler, Valerie; Peshkova, Alina D.; Andrianova, Izabella A.; Khasanova, Dina R.; Weisel, John W.; Litvinov, Rustem I.
2016-01-01
Objective Obstructive thrombi or thrombotic emboli are the pathogenic basis of ischemic stroke. In vitro blood clots and in vivo thrombi can undergo platelet-driven contraction (retraction), resulting in volume shrinkage. Clot contraction can potentially reduce vessel occlusion and improve blood flow past emboli or thrombi. The aim of this work was to examine a potential pathogenic role of clot contraction in ischemic stroke. Approach and Results We employed a novel automated method that enabled us to quantify time of initiation, extent and rate of clot contraction in vitro. The main finding is clot contraction from the blood of stroke patients was reduced compared to healthy subjects. Reduced clot contraction correlated with a lower platelet count and their dysfunction, higher levels of fibrinogen and hematocrit, leukocytosis and other changes in blood composition that may affect platelet function and properties of blood clots. Platelets from stroke patents were spontaneously activated and displayed reduced responsiveness to additional stimulation. Clinical correlations with respect to severity and stroke etiology suggest that the impaired clot contraction has the potential to be a pathogenic factor in ischemic stroke. Conclusions The changeable ability of clots and thrombi to shrink in volume may be a novel unappreciated mechanism that aggravates or alleviates the course and outcomes of ischemic stroke. The clinical importance of clot or thrombus transformations in vivo and the diagnostic and prognostic value of this blood test for clot contraction needs further exploration. PMID:27908894
Temperature analysis with voltage-current time differential operation of electrochemical sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woo, Leta Yar-Li; Glass, Robert Scott; Fitzpatrick, Joseph Jay
A method for temperature analysis of a gas stream. The method includes identifying a temperature parameter of an affected waveform signal. The method also includes calculating a change in the temperature parameter by comparing the affected waveform signal with an original waveform signal. The method also includes generating a value from the calculated change which corresponds to the temperature of the gas stream.
Cines, Douglas B.; Lebedeva, Tatiana; Nagaswami, Chandrasekaran; Hayes, Vincent; Massefski, Walter; Litvinov, Rustem I.; Rauova, Lubica; Lowery, Thomas J.
2014-01-01
Contraction of blood clots is necessary for hemostasis and wound healing and to restore flow past obstructive thrombi, but little is known about the structure of contracted clots or the role of erythrocytes in contraction. We found that contracted blood clots develop a remarkable structure, with a meshwork of fibrin and platelet aggregates on the exterior of the clot and a close-packed, tessellated array of compressed polyhedral erythrocytes within. The same results were obtained after initiation of clotting with various activators and also with clots from reconstituted human blood and mouse blood. Such close-packed arrays of polyhedral erythrocytes, or polyhedrocytes, were also observed in human arterial thrombi taken from patients. The mechanical nature of this shape change was confirmed by polyhedrocyte formation from the forces of centrifugation of blood without clotting. Platelets (with their cytoskeletal motility proteins) and fibrin(ogen) (as the substrate bridging platelets for contraction) are required to generate the forces necessary to segregate platelets/fibrin from erythrocytes and to compress erythrocytes into a tightly packed array. These results demonstrate how contracted clots form an impermeable barrier important for hemostasis and wound healing and help explain how fibrinolysis is greatly retarded as clots contract. PMID:24335500
Blood thinners are medicines that prevent blood clots from forming. They also keep existing blood clots from getting larger. Clots in your arteries, ... down your body's process of making clots. Antiplatelet drugs, such as aspirin, prevent blood cells called platelets ...
Radar altimeter waveform modeled parameter recovery. [SEASAT-1 data
NASA Technical Reports Server (NTRS)
1981-01-01
Satellite-borne radar altimeters include waveform sampling gates providing point samples of the transmitted radar pulse after its scattering from the ocean's surface. Averages of the waveform sampler data can be fitted by varying parameters in a model mean return waveform. The theoretical waveform model used is described as well as a general iterative nonlinear least squares procedures used to obtain estimates of parameters characterizing the modeled waveform for SEASAT-1 data. The six waveform parameters recovered by the fitting procedure are: (1) amplitude; (2) time origin, or track point; (3) ocean surface rms roughness; (4) noise baseline; (5) ocean surface skewness; and (6) altitude or off-nadir angle. Additional practical processing considerations are addressed and FORTRAN source listing for subroutines used in the waveform fitting are included. While the description is for the Seasat-1 altimeter waveform data analysis, the work can easily be generalized and extended to other radar altimeter systems.
Minamimoto, Ryogo; Hamabe, Yoshimi; Miyaoka, Teiji; Hara, Takamitsu; Yoshida, Keisuke; Oka, Takashi; Inoue, Tomio
2008-12-01
Phase 0 clinical studies, which are known as microdose trials, are expected to promote drug development and reduce development costs. The accelerator mass spectrometry (AMS) system is expected to play an important role in the microdosing tests, as it is a highly sensitive measurement system that can be used to determine the drug concentrations in these tests. Using the AMS system, we measured the background (14)C-concentration in human blood and evaluated the data for use as a reference in microdose studies that administer (14)C-labeled compounds in humans. Blood samples of five healthy Japanese volunteers (three men, two women, median age 40.4 +/- 9.8 years) were collected around the same time and just prior to when the subjects ate a meal (between 12:00 noon and 2:00 pm). Centrifugal separations of blood that was allowed to clot and the plasma were performed at 503 g for 2 min at 4 degrees C. Background (14)C-concentration for each of the samples was measured using the AMS system. The Institute of Accelerator Analysis, which is the first contract research organization in Japan that is capable of providing AMS analysis services for carbon dating and bioanalysis work, performed the AMS analysis. The mean (14)C-concentration in blood was 1.613 +/- 0.125 dpm/ml (men 1.668 +/- 0.114 dpm/ml, women 1.514 +/- 0.076 dpm/ml), in clots 2.373 +/- 0.087 dpm/ml (men 2.381 +/- 0.101 dpm/ml, women 2.357 +/- 0.060 dpm/ ml), and in plasma 0.648 +/- 0.049 dpm/ml (men 0.647 +/- 0.059 dpm/ml, women 0.649 +/- 0.032 dpm/ml). The coefficient variation (CV) for blood was 7.8% (men 6.9%, women 5.0%), for clots 3.7% (men 4.3%, women 2.5%), and for plasma 7.6% (men 9.1%, women 4.9%). The (14)C-concentrations of the clot and blood were higher than those of plasma. The (14)C-concentrations in the blood and plasma were slightly different between individuals when compared with the values for the clot, although the differences were quite small, with a CV value less than 7.8%. Even though the (14)C-concentration differed only slightly between individuals, (14)C-concentrations of the clot and blood were higher than those of the plasma. Therefore, the variation and difference of the background data for blood and plasma might be of use as a reference for microdosing test evaluations.
The hydraulic permeability of blood clots as a function of fibrin and platelet density.
Wufsus, A R; Macera, N E; Neeves, K B
2013-04-16
Interstitial fluid flow within blood clots is a biophysical mechanism that regulates clot growth and dissolution. Assuming that a clot can be modeled as a porous medium, the physical property that dictates interstitial fluid flow is the hydraulic permeability. The objective of this study was to bound the possible values of the hydraulic permeability in clots formed in vivo and present relationships that can be used to estimate clot permeability as a function of composition. A series of clots with known densities of fibrin and platelets, the two major components of a clot, were formed under static conditions. The permeability was calculated by measuring the interstitial fluid velocity through the clots at a constant pressure gradient. Fibrin gels formed with a fiber volume fraction of 0.02-0.54 had permeabilities of 1.2 × 10(-1)-1.5 × 10(-4)μm(2). Platelet-rich clots with a platelet volume fraction of 0.01-0.61 and a fibrin volume fraction of 0.03 had permeabilities over a range of 1.1 × 10(-2)-1.5 × 10(-5)μm(2). The permeability of fibrin gels and of clots with platelet volume fraction of <0.2 were modeled as an array of disordered cylinders with uniform diameters. Clots with a platelet volume fraction of >0.2 were modeled as a Brinkman medium of coarse solids (platelets) embedded in a mesh of fine fibers (fibrin). Our data suggest that the permeability of clots formed in vivo can vary by up to five orders of magnitude, with pore sizes that range from 4 to 350 nm. These findings have important implications for the transport of coagulation zymogens/enzymes in the interstitial spaces during clot formation, as well as the design of fibrinolytic drug delivery strategies. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.
The Hydraulic Permeability of Blood Clots as a Function of Fibrin and Platelet Density
Wufsus, A.R.; Macera, N.E.; Neeves, K.B.
2013-01-01
Interstitial fluid flow within blood clots is a biophysical mechanism that regulates clot growth and dissolution. Assuming that a clot can be modeled as a porous medium, the physical property that dictates interstitial fluid flow is the hydraulic permeability. The objective of this study was to bound the possible values of the hydraulic permeability in clots formed in vivo and present relationships that can be used to estimate clot permeability as a function of composition. A series of clots with known densities of fibrin and platelets, the two major components of a clot, were formed under static conditions. The permeability was calculated by measuring the interstitial fluid velocity through the clots at a constant pressure gradient. Fibrin gels formed with a fiber volume fraction of 0.02–0.54 had permeabilities of 1.2 × 10−1–1.5 × 10−4μm2. Platelet-rich clots with a platelet volume fraction of 0.01–0.61 and a fibrin volume fraction of 0.03 had permeabilities over a range of 1.1 × 10−2–1.5 × 10−5μm2. The permeability of fibrin gels and of clots with platelet volume fraction of <0.2 were modeled as an array of disordered cylinders with uniform diameters. Clots with a platelet volume fraction of >0.2 were modeled as a Brinkman medium of coarse solids (platelets) embedded in a mesh of fine fibers (fibrin). Our data suggest that the permeability of clots formed in vivo can vary by up to five orders of magnitude, with pore sizes that range from 4 to 350 nm. These findings have important implications for the transport of coagulation zymogens/enzymes in the interstitial spaces during clot formation, as well as the design of fibrinolytic drug delivery strategies. PMID:23601328
Martinez, Marissa R; Cuker, Adam; Mills, Angela M; Crichlow, Amanda; Lightfoot, Richard T; Chernysh, Irina N; Nagaswami, Chandrasekaran; Weisel, John W; Ischiropoulos, Harry
2014-03-01
The factors that contribute to pulmonary embolism (PE), a potentially fatal complication of deep vein thrombosis (DVT), remain poorly understood. Whereas fibrin clot structure and functional properties have been implicated in the pathology of venous thromboembolism and the risk for cardiovascular complications, their significance in PE remains uncertain. Therefore, we systematically compared and quantified clot formation and lysis time, plasminogen levels, viscoelastic properties, activated factor XIII cross-linking, and fibrin clot structure in isolated DVT and PE subjects. Clots made from plasma of PE subjects showed faster clot lysis times with no differences in lag time, rate of clot formation, or maximum absorbance of turbidity compared with DVT. Differences in lysis times were not due to alterations in plasminogen levels. Compared with DVT, clots derived from PE subjects showed accelerated establishment of viscoelastic properties, documented by a decrease in lag time and an increase in the rate of viscoelastic property formation. The rate and extent of fibrin cross-linking by activated factor XIII were similar between clots from DVT and PE subjects. Electron microscopy revealed that plasma fibrin clots from PE subjects exhibited lower fiber density compared with those from DVT subjects. These data suggest that clot structure and functional properties differ between DVT and PE subjects and provide insights into mechanisms that may regulate embolization.
Martinez, Marissa R.; Cuker, Adam; Mills, Angela M.; Crichlow, Amanda; Lightfoot, Richard T.; Chernysh, Irina N.; Nagaswami, Chandrasekaran; Weisel, John W.
2014-01-01
The factors that contribute to pulmonary embolism (PE), a potentially fatal complication of deep vein thrombosis (DVT), remain poorly understood. Whereas fibrin clot structure and functional properties have been implicated in the pathology of venous thromboembolism and the risk for cardiovascular complications, their significance in PE remains uncertain. Therefore, we systematically compared and quantified clot formation and lysis time, plasminogen levels, viscoelastic properties, activated factor XIII cross-linking, and fibrin clot structure in isolated DVT and PE subjects. Clots made from plasma of PE subjects showed faster clot lysis times with no differences in lag time, rate of clot formation, or maximum absorbance of turbidity compared with DVT. Differences in lysis times were not due to alterations in plasminogen levels. Compared with DVT, clots derived from PE subjects showed accelerated establishment of viscoelastic properties, documented by a decrease in lag time and an increase in the rate of viscoelastic property formation. The rate and extent of fibrin cross-linking by activated factor XIII were similar between clots from DVT and PE subjects. Electron microscopy revealed that plasma fibrin clots from PE subjects exhibited lower fiber density compared with those from DVT subjects. These data suggest that clot structure and functional properties differ between DVT and PE subjects and provide insights into mechanisms that may regulate embolization. PMID:24414255
Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi
2008-09-01
The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.
Vocal fold vibrations: high-speed imaging, kymography, and acoustic analysis: a preliminary report.
Larsson, H; Hertegård, S; Lindestad, P A; Hammarberg, B
2000-12-01
To evaluate a new analysis system, High-Speed Tool Box (H. Larsson, custom-made program for image analysis, version 1.1, Department of Logopedics and Phoniatrics, Huddinge University Hospital, Huddinge, Sweden, 1998) for studying vocal fold vibrations using a high-speed camera and to relate findings from these analyses to sound characteristics. A Weinberger Speedcam + 500 system (Weinberger AG, Dietikon, Switzerland) was used with a frame rate of 1,904 frames per second. Images were stored and analyzed digitally. Analysis included automatic glottal edge detection and calculation of glottal area variations, as well as kymography. These signals were compared with acoustic waveforms using the Soundswell program (Hitech Development AB, Stockholm, Sweden). The High-Speed Tool Box was applied on two types of high-speed recordings: a diplophonic phonation and a tremor voice. Relations between glottal vibratory patterns and the sound waveform were analyzed. In the diplophonic phonation, the glottal area waveform, as well as the kymogram, showed a specific pattern of repetitive glottal closures, which was also seen in the acoustic waveform. In the tremor voice, fundamental frequency (F0) fluctuations in the acoustic waveform were reflected in slow variations in amplitude in the glottal area waveform. For studying details of mucosal movements during these kinds of abnormal vibrations, the glottal area waveform was particularly useful. Our results suggest that this combined high-speed acoustic-kymographic analysis package is a promising aid for separating and specifying different voice qualities such as diplophonia and voice tremor. Apart from clinical use, this finding should be of help for specification of the terminology of different voice qualities.
Heeremans, J L; Prevost, R; Feitsma, H; Kluft, C; Crommelin, D J
1998-01-01
In this study, the clot accumulation properties of liposome-coupled plasminogen were compared to those of free (non-liposomal) plasminogen in an in vitro, closed-loop, flow-system. After introduction of a clot into the closed system, double-radiolabelled plasminogen-liposomes were administered and the accumulation of radiolabel on the entire clot was measured. Liposomal plasminogen showed improved accumulation over free plasminogen, on both a fibrin clot and a whole blood clot. Moreover, once liposomal plasminogen was fibrin associated, it could not be washed away with buffer, in contrast to free plasminogen. Liposomal plasminogen was able to compete successfully with an excess of free plasminogen. The plateau levels for the accumulated amount of plasminogen depended on the incubated amount of plasminogen and were influenced by partial degradation of the clot. Furthermore, it was shown that a threshold liposomal plasminogen surface-density was needed for optimum clot accumulation.
Diagnosing human blood clotting deficiency.
Ong, Chong Cheen; Gopinath, Subash C B; Rebecca, Leong Wei Xian; Perumal, Veeradasan; Lakshmipriya, Thangavel; Saheed, Mohamed Shuaib Mohamed
2018-05-15
There are different clotting factors present in blood, carries the clotting cascade and excessive bleeding may cause a deficiency in the clotting Diagnosis of this deficiency in clotting drastically reduces the potential fatality. For enabling a sensor to detect the clotting factors, suitable probes such as antibody and aptamer have been used to capture these targets on the sensing surface. Two major clotting factors were widely studied for the diagnosis of clotting deficiency, which includes factor IX and thrombin. In addition, factor IX is considered as the substitute for heparin and the prothrombotic associated with the increased thrombin generation are taking into account their prevalence. The biosensors, surface plasmon resonance, evanescent-field-coupled waveguide-mode sensor, metal-enhanced PicoGreen fluorescence and electrochemical aptasensor were well-documented and improvements have been made for high-performance sensing. We overviewed detecting factor IX and thrombin using these biosensors, for the potential application in medical diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Developing Mesoscale Model of Fibrin-Platelet Network Representing Blood Clotting =
NASA Astrophysics Data System (ADS)
Sun, Yueyi; Nikolov, Svetoslav; Bowie, Sam; Alexeev, Alexander; Lam, Wilbur; Myers, David
Blood clotting disorders which prevent the body's natural ability to achieve hemostasis can lead to a variety of life threatening conditions such as, excessive bleeding, stroke, or heart attack. Treatment of these disorders is highly dependent on understanding the underlying physics behind the clotting process. Since clotting is a highly complex multi scale mechanism developing a fully atomistic model is currently not possible. We develop a mesoscale model based on dissipative particle dynamics (DPD) to gain fundamental understanding of the underlying principles controlling the clotting process. In our study, we examine experimental data on clot contraction using stacks of confocal microscopy images to estimate the crosslink density in the fibrin networks and platelet location. Using this data we reconstruct the platelet rich fibrin network and study how platelet-fibrin interactions affect clotting. Furthermore, we probe how different system parameters affect clot contraction. ANSF CAREER Award DMR-1255288.
Threshold Switchable Particles (TSPs) To Control Internal Hemorrhage
2016-09-01
hemorrhage at local sites. Four collaborating laboratories worked together under this contract to define threshold levels of activators of blood clotting...such that the candidate clotting activators will circulate in the blood at a concentration below the threshold necessary to trigger clotting, but...accumulation of the activators at sites of internal injury/bleeding will cause the local concentration of clotting activators to exceed the clotting
Factor XIII stiffens fibrin clots by causing fiber compaction.
Kurniawan, N A; Grimbergen, J; Koopman, J; Koenderink, G H
2014-10-01
Factor XIII-induced cross-linking has long been associated with the ability of fibrin blood clots to resist mechanical deformation, but how FXIII can directly modulate clot stiffness is unknown. We hypothesized that FXIII affects the self-assembly of fibrin fibers by altering the lateral association between protofibrils. To test this hypothesis, we studied the cross-linking kinetics and the structural evolution of the fibers and clots during the formation of plasma-derived and recombinant fibrins by using light scattering, and the response of the clots to mechanical stresses by using rheology. We show that the lateral aggregation of fibrin protofibrils initially results in the formation of floppy fibril bundles, which then compact to form tight and more rigid fibers. The first stage is reflected in a fast (10 min) increase in clot stiffness, whereas the compaction phase is characterized by a slow (hours) development of clot stiffness. Inhibition of FXIII completely abrogates the slow compaction. FXIII strongly increases the linear elastic modulus of the clots, but does not affect the non-linear response at large deformations. We propose a multiscale structural model whereby FXIII-mediated cross-linking tightens the coupling between the protofibrils within a fibrin fiber, thus making the fiber stiffer and less porous. At small strains, fiber stiffening enhances clot stiffness, because the clot response is governed by the entropic elasticity of the fibers, but once the clot is sufficiently stressed, the modulus is independent of protofibril coupling, because clot stiffness is governed by individual protofibril stretching. © 2014 International Society on Thrombosis and Haemostasis.
High-speed shaking of frozen blood clots for extraction of human and malaria parasite DNA
2011-01-01
Background Frozen blood clots remaining after serum collection is an often disregarded source of host and pathogen DNA due to troublesome handling and suboptimal outcome. Methods High-speed shaking of clot samples in a cell disruptor manufactured for homogenization of tissue and faecal specimens was evaluated for processing frozen blood clots for DNA extraction. The method was compared to two commercial clot protocols based on a chemical kit and centrifugation through a plastic sieve, followed by the same DNA extraction protocol. Blood clots with different levels of parasitaemia (1-1,000 p/μl) were prepared from parasite cultures to assess sensitivity of PCR detection. In addition, clots retrieved from serum samples collected within two epidemiological studies in Kenya (n = 630) were processed by high speed shaking and analysed by PCR for detection of malaria parasites and the human α-thalassaemia gene. Results High speed shaking succeeded in fully dispersing the clots and the method generated the highest DNA yield. The level of PCR detection of P. falciparum parasites and the human thalassaemia gene was the same as samples optimally collected with an anticoagulant. The commercial clot protocol and centrifugation through a sieve failed to fully dissolve the clots and resulted in lower sensitivity of PCR detection. Conclusions High speed shaking was a simple and efficacious method for homogenizing frozen blood clots before DNA purification and resulted in PCR templates of high quality both from humans and malaria parasites. This novel method enables genetic studies from stored blood clots. PMID:21824391
A targeted ferritin-microplasmin based thrombolytic nanocage selectively dissolves blood clots.
Seo, Junyoung; Al-Hilal, Taslim A; Jee, Jun-Goo; Kim, Yong-Lim; Kim, Ha-Jeong; Lee, Byung-Heon; Kim, Soyoun; Kim, In-San
2018-04-01
The use of thrombolytic therapies is limited by an increased risk of systemic hemorrhage due to lysis of hemostatic clots. We sought to develop a plasmin-based thrombolytic nanocage that efficiently dissolves the clot without causing systemic fibrinolysis or disrupting hemostatic clots. Here, we generated a double chambered short-length ferritin (sFt) construct that has an N-terminal region fused to multivalent clot targeting peptides (CLT: CNAGESSKNC) and a C-terminal end fused to a microplasmin (μPn); CLT recognizes fibrin-fibronectin complexes in clots, μPn efficiently dissolves clots, and the assembly of double chambered sFt (CLT-sFt-μPn) into nanocage structure protects the activated-μPn from its circulating inhibitors. Importantly, activated CLT-sFt-μPn thrombolytic nanocage showed a prolonged circulatory life over activated-μPn and efficiently lysed the preexisting clots in both arterial and venous thromboses models. Thus, CLT-sFt-μPn thrombolytic nanocage platform represents the prototype of a targeted clot-busting agent with high efficacy and safety over existing thrombolytic therapies. Copyright © 2018 Elsevier Inc. All rights reserved.
Too much TV causes lung blood clot deaths.
2016-08-10
Lung blood clots - also known as pulmonary embolisms - usually stem from clots in the leg or pelvis after inactivity has slowed blood flow. It is particularly dangerous if the clot travels to the lung and lodges in a small blood vessel.
Activated Monocytes Enhance Platelet-Driven Contraction of Blood Clots via Tissue Factor Expression.
Peshkova, Alina D; Le Minh, Giang; Tutwiler, Valerie; Andrianova, Izabella A; Weisel, John W; Litvinov, Rustem I
2017-07-11
Platelet-driven reduction in blood clot volume (clot contraction or retraction) has been implicated to play a role in hemostasis and thrombosis. Although these processes are often linked with inflammation, the role of inflammatory cells in contraction of blood clots and thrombi has not been investigated. The aim of this work was to study the influence of activated monocytes on clot contraction. The effects of monocytes were evaluated using a quantitative optical tracking methodology to follow volume changes in a blood clot formed in vitro. When a physiologically relevant number of isolated human monocytes pre-activated with phorbol-12-myristate-13-acetate (PMA) were added back into whole blood, the extent and rate of clot contraction were increased compared to addition of non-activated cells. Inhibition of tissue factor expression or its inactivation on the surface of PMA-treated monocytes reduced the extent and rate of clot contraction back to control levels with non-activated monocytes. On the contrary, addition of tissue factor enhanced clot contraction, mimicking the effects of tissue factor expressed on the activated monocytes. These data suggest that the inflammatory cells through their expression of tissue factor can directly affect hemostasis and thrombosis by modulating the size and density of intra- and extravascular clots and thrombi.
Kindell, Daniel Glenn; Keck, Rick Wayne; Jankun, Jerzy
2015-06-01
Plasminogen activator inhibitor (PAI)-1 is a serpin glycoprotein that can stabilize blood clots by inhibiting fibrinolysis. However, wild-type PAI-1 has the disadvantage of a short half-life of ∼2 h. A very long half-life (VLHL) PAI-1 mutant was developed previously with an active-form half-life of >700 h, making it a possible candidate for use in hemorrhagic therapy. Current treatments for mitigating hemorrhage, other than inducers of blood clotting, are limited to lysine analog antifibrinolytics, including 6-aminocaproic acid and tranexamic acid. VLHL PAI-1 has been previously demonstrated to limit bleeding; however, the efficacy of this protein compared with lysine analog antifibrinolytics has not been investigated. The aim of the current study was to compare the clot stabilizing properties of the novel antifibrinolytic VLHL PAI-1 with those of 6-aminocaproic acid in reference plasma. Using thromboelastographic analysis, VLHL PAI-1 exhibited an IC 50 (half maximal inhibitory concentration) of 8.8×10 -8 mol/l, while 6-aminocaproic acid showed an IC 50 of 1.6×10 -4 mol/l. However, at doses of >9.0×10 -7 mol/l, VLHL PAI-1 exhibited a delay in the onset of clot formation, which may be attributed to thrombin inhibition by excess PAI-1. The inhibition of tissue plasminogen activator by VLHL PAI-1 demonstrated improved efficacy over 6-aminocaproic acid in mitigating hemorrhage. In addition, patients with a PAI-1 deficiency, which causes blood clots to lyse rapidly resulting in profuse bleeding, may benefit from the application of VLHL PAI-1 as an antihemorrhagic therapy.
KINDELL, DANIEL GLENN; KECK, RICK WAYNE; JANKUN, JERZY
2015-01-01
Plasminogen activator inhibitor (PAI)-1 is a serpin glycoprotein that can stabilize blood clots by inhibiting fibrinolysis. However, wild-type PAI-1 has the disadvantage of a short half-life of ∼2 h. A very long half-life (VLHL) PAI-1 mutant was developed previously with an active-form half-life of >700 h, making it a possible candidate for use in hemorrhagic therapy. Current treatments for mitigating hemorrhage, other than inducers of blood clotting, are limited to lysine analog antifibrinolytics, including 6-aminocaproic acid and tranexamic acid. VLHL PAI-1 has been previously demonstrated to limit bleeding; however, the efficacy of this protein compared with lysine analog antifibrinolytics has not been investigated. The aim of the current study was to compare the clot stabilizing properties of the novel antifibrinolytic VLHL PAI-1 with those of 6-aminocaproic acid in reference plasma. Using thromboelastographic analysis, VLHL PAI-1 exhibited an IC50 (half maximal inhibitory concentration) of 8.8×10−8 mol/l, while 6-aminocaproic acid showed an IC50 of 1.6×10−4 mol/l. However, at doses of >9.0×10−7 mol/l, VLHL PAI-1 exhibited a delay in the onset of clot formation, which may be attributed to thrombin inhibition by excess PAI-1. The inhibition of tissue plasminogen activator by VLHL PAI-1 demonstrated improved efficacy over 6-aminocaproic acid in mitigating hemorrhage. In addition, patients with a PAI-1 deficiency, which causes blood clots to lyse rapidly resulting in profuse bleeding, may benefit from the application of VLHL PAI-1 as an antihemorrhagic therapy. PMID:26136983
Fiber-based optic sensor for detecting human blood clot: present and future revival
NASA Astrophysics Data System (ADS)
Elshikeri, Nada; Bakhtiar, Hazri
2018-05-01
Sustaining human’s life-frame away from being impeded by the clot - ghost term, we attempt to approach a mobile fiber-based optical sensor (f-s) for detecting blood clot in a blood vessel (intra-arteries/veins). Blood vessels are the part of the circulatory system that transport blood throughout the human body, thus their significance of being protected arise to the monograph focus. MRI (magnetic resonance imaging), X-rays and other medical instruments are diagnostic immobility techniques with a slackest interval. The corer causation of fiber-based optical sensor is to detect a clump of blood in the bloodstream by providing a prompt mobile diagnostic intervals preserving last-minutes-breath of human’s life. The detector (f-s) has been etched by diluting sulphuric acid ~10% at certain zone to sensate its function. The in-vitro monograph peaks its maximal monitoring when the sensor is attached to Raman Spectroscopy (RS) setup. RS quantifies the relative intensities of fibrinogen bond, which is the first type of blood coagulation elements of blood plasma. Blood coagulation parameters are the major concern of the monograph investigation, such as total haemoglobin (tHb), clotting reaction time (t), clot progression time (t2), maximum clot amplitude (ma) and mean refractive index (r). A blood sample will be drawn from the patient and after centrifugation to separate blood plasma from its constituents, then an immediate sloshing of blood plasma in the (f-s) packet which has its plug-in to RS. Estimating the quantitative analysis of blood sample concentration, RS will determine the presence of coagulation in terms of intensity and medical procedures will dominate the treatment process. Thus, the suggestive monograph provides a definite instrument for investigating blood coagulation intra-arteries/veins promptly.
Effect of solvent/detergent-treated pooled plasma on fibrinolysis in reconstituted whole blood.
Saadah, Nicholas H; van der Meer, Pieter F; Brinkman, Herm Jan M; de Korte, Dirk; Bontekoe, Ido J; Korsten, Herbert H; Middelburg, Rutger A; van der Bom, Johanna G; Schipperus, Martin R
2017-10-01
Hyperfibrinolysis has been observed in patients heavily transfused with solvent/detergent-treated pooled plasma (S/D plasma). We compared coagulation and fibrinolytic variables in blood containing S/D plasma with blood containing fresh-frozen plasma (FFP), with and without α2-antiplasmin or tranexamic acid (TXA) supplementation. Whole blood samples were reconstituted from red blood cells, platelet (PLT) concentrates, and varying mixtures of FFP and S/D plasma. Hematocrit and PLT count of reconstituted whole blood samples were varied. For a subset of runs, α2-antiplasmin or TXA was added to S/D plasma whole blood samples. Thromboelastography (TEG) analysis was performed to assess 50% clot lysis time (CLT 50% ), maximum amplitude (MA), and initial clotting time (R-time). The change in CLT 50% of whole blood as the plasma compartment transitions from FFP to S/D plasma was -52% (95% confidence interval [CI], -60% to -45%; p < 0.001). PLT count strengthened the effect, leading to an additional change in CLT 50% of -8% (95% CI, -14% to -2%; p = 0.012) as PLT count increased from 10 × 10 9 to 150 × 10 9 /L. MA and R-time were not associated with fraction of S/D plasma in whole blood. α2-Antiplasmin and TXA restored clot lysis time in S/D plasma whole blood. Whole blood with S/D plasma has shorter clot lysis times in vitro compared to whole blood with FFP. α2-Antiplasmin and TXA restore clot lysis time of S/D plasma whole blood to that of FFP whole blood. Clinicians should be aware of the decreased clot lysis time associated with S/D plasma transfusion. © 2017 AABB.
Time domain reflectometry waveform analysis with second order bounded mean oscillation
USDA-ARS?s Scientific Manuscript database
Tangent-line methods and adaptive waveform interpretation with Gaussian filtering (AWIGF) have been proposed for determining reflection positions of time domain reflectometry (TDR) waveforms. However, the accuracy of those methods is limited for short probe TDR sensors. Second order bounded mean osc...
Pulsed Phase Lock Loop Device for Monitoring Intracranial Pressure During Space Flight
NASA Technical Reports Server (NTRS)
Ueno, Toshiaki; Macias, Brandon R.; Yost, William T.; Hargens, Alan R.
2003-01-01
We have developed an ultrasonic device to monitor ICP waveforms non-invasively from cranial diameter oscillations using a NASA-developed pulsed phase lock loop (PPLL) technique. The purpose of this study was to attempt to validate the PPLL device for reliable recordings of ICP waveforms and analysis of ICP dynamics in vivo. METHODS: PPLL outputs were recorded in patients during invasive ICP monitoring at UCSD Medical Center (n=10). RESULTS: An averaged linear regression coefficient between ICP and PPLL waveform data during one cardiac cycle in all patients is 0.88 +/- 0.02 (mean +/- SE). Coherence function analysis indicated that ICP and PPLL waveforms have high correlation in the lst, 2nd, and 3rd harmonic waves associated with a cardiac cycle. CONCLUSIONS: PPLL outputs represent ICP waveforms in both frequency and time domains. PPLL technology enables in vivo evaluation of ICP dynamics non-invasively, and can acquire continuous ICP waveforms during spaceflight because of compactness and non-invasive nature.
A long source area of the 1906 Colombia-Ecuador earthquake estimated from observed tsunami waveforms
NASA Astrophysics Data System (ADS)
Yamanaka, Yusuke; Tanioka, Yuichiro; Shiina, Takahiro
2017-12-01
The 1906 Colombia-Ecuador earthquake induced both strong seismic motions and a tsunami, the most destructive earthquake in the history of the Colombia-Ecuador subduction zone. The tsunami propagated across the Pacific Ocean, and its waveforms were observed at tide gauge stations in countries including Panama, Japan, and the USA. This study conducted slip inverse analysis for the 1906 earthquake using these waveforms. A digital dataset of observed tsunami waveforms at the Naos Island (Panama) and Honolulu (USA) tide gauge stations, where the tsunami was clearly observed, was first produced by consulting documents. Next, the two waveforms were applied in an inverse analysis as the target waveform. The results of this analysis indicated that the moment magnitude of the 1906 earthquake ranged from 8.3 to 8.6. Moreover, the dominant slip occurred in the northern part of the assumed source region near the coast of Colombia, where little significant seismicity has occurred, rather than in the southern part. The results also indicated that the source area, with significant slip, covered a long distance, including the southern, central, and northern parts of the region.[Figure not available: see fulltext.
Badiei, N; Sowedan, A M; Curtis, D J; Brown, M R; Lawrence, M J; Campbell, A I; Sabra, A; Evans, P A; Weisel, J W; Chernysh, I N; Nagaswami, C; Williams, P R; Hawkins, K
2015-01-01
Incipient clot formation in whole blood and fibrin gels was studied by the rheometric techniques of controlled stress parallel superposition (CSPS) and small amplitude oscillatory shear (SAOS). The effects of unidirectional shear stress on incipient clot microstructure, formation kinetics and elasticity are reported in terms of the fractal dimension (df) of the fibrin network, the gel network formation time (TGP) and the shear elastic modulus, respectively. The results of this first haemorheological application of CSPS reveal the marked sensitivity of incipient clot microstructure to physiologically relevant levels of shear stress, these being an order of magnitude lower than have previously been studied by SAOS. CSPS tests revealed that exposure of forming clots to increasing levels of shear stress produces a corresponding elevation in df, consistent with the formation of tighter, more compact clot microstructures under unidirectional flow. A corresponding increase in shear elasticity was recorded. The scaling relationship established between shear elasticity and df for fibrin clots and whole blood confirms the fibrin network as the dominant microstructural component of the incipient clot in terms of its response to imposed stress. Supplementary studies of fibrin clot formation by rheometry and microscopy revealed the substantial additional network mass required to increase df and provide evidence to support the hypothesis that microstructural changes in blood clotted under unidirectional shear may be attributed to flow enhanced thrombin generation and activation. CSPS also identified a threshold value of unidirectional shear stress above which no incipient clot formation could be detected. CSPS was shown to be a valuable haemorheological tool for the study of the effects of physiological and pathological levels of shear on clot properties.
Activation of platelet-rich plasma using soluble type I collagen.
Fufa, Duretti; Shealy, Blake; Jacobson, May; Kevy, Sherwin; Murray, Martha M
2008-04-01
Platelet-rich plasma (PRP) has recently been found to be a useful delivery system for growth factors important to oral tissue healing. But application of PRP in a liquid form to a wound site within the oral cavity can be complicated by significant loss of the PRP into the surrounding oral space unless gelation through the clotting mechanism is accomplished. Gelation is currently accomplished using bovine thrombin; however, rare but serious complications of this method have led to the search for alternative clotting mechanisms, including the use of soluble collagen as a clotting activator. In this work, our hypothesis was that soluble type I collagen would be as effective as bovine thrombin in causing clotting of the PRP and stimulating growth factor release from the platelets and granulocytes. PRP from human donors was clotted using type I collagen or bovine thrombin. Clot retraction was determined by measuring clot diameters over time. The release of platelet-derived growth factor (PDGF)-AB, transforming growth factor (TGF)-beta1, and vascular endothelial growth factor (VEGF) from both types of clots was measured over 10 days using enzyme-linked immunosorbent assasy. Clots formed using type I collagen exhibited far less retraction than those formed with bovine thrombin. Bovine thrombin and type I collagen stimulated similar release of PDGF-AB and VEGF between 1 and 10 days; however, thrombin activation resulted in a greater release of TGF-beta1 during the first 5 days after activation. The use of type I collagen to activate clotting of PRP may be a safe and effective alternative to bovine thrombin. The use of collagen results in less clot retraction and equal release of PDGF-AB and VEGF compared with currently available methods of clot activation.
ACTIVATION OF PLATELET-RICH PLASMA USING SOLUBLE TYPE I COLLAGEN
Fufa, Duretti; Shealy, Blake; Jacobson, May; Kevy, Sherwin; Murray, Martha M.
2008-01-01
PURPOSE Platelet-rich plasma (PRP) has recently been found to be a useful delivery system for growth factors important in oral tissue healing. However, application of PRP in a liquid form to a wound site within the oral cavity can be complicated by significant loss of the PRP into the surrounding oral space unless gelation via the clotting mechanism is accomplished. Gelation is currently accomplished using bovine thrombin; however, rare but serious complications of this method have led to the search for alternative clotting mechanisms, including the use of soluble collagen as a clotting activator. In this paper, our hypothesis was that soluble Type I collagen would be as effective as bovine thrombin in causing clotting of the PRP and of stimulating growth factor release from the platelets and granulocytes. MATERIALS AND METHODS PRP from human donors was clotted using Type I collagen or bovine thrombin. Clot retraction was determined by measuring clot diameters over time. The release of PDGF-AB, TGF-β1 and VEGF from both types of clots was measured over 10 days using ELISA. RESULTS Clots formed using Type I collagen had far less retraction than those formed with bovine thrombin. Bovine thrombin and Type I collagen stimulated similar release of PDGF-AB and VEGF between 1 and 10 days; however, thrombin activation resulted in a greater release of TGF-β1 during the first five days after activation. CONCLUSIONS The use of Type I collagen to activate clotting of PRP may be a safe and effective alternative to bovine thrombin. The use of collagen results in less clot retraction and equal release of PDGF-AB and VEGF when compared to currently available methods of clot activation. PMID:18355591
Structure, Mechanics, and Instability of Fibrin Clot Infected with Staphylococcus epidermidis.
Ma, Tianhui Maria; VanEpps, J Scott; Solomon, Michael J
2017-11-07
Health care-associated infection, over half of which can be attributed to indwelling medical devices, is a strong risk factor for thromboembolism. Although most experimental models of medical device infection draw upon isolated bacterial biofilms, in fact there is no infection without host protein contribution. Here we study, to our knowledge, a new model for medical device infection-that of an infected fibrin clot-and show that the common blood-borne pathogen Staphylococcus epidermidis influences this in vitro model of a blood clot mechanically and structurally on both microscopic and macroscopic scales. Bacteria present during clot formation produce a visibly disorganized microstructure that increases clot stiffness and triggers mechanical instability over time. Our results provide insight into the observed correlation between medical device infection and thromboembolism; the increase in model clot heterogeneity shows that S. epidermidis can rupture a fibrin clot. The resultant embolization of the infected clot can contribute to the systemic dissemination of the pathogen. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Sutton, Jonathan T.; Ivancevich, Nikolas M.; Perrin, Stephen R.; Vela, Deborah C.; Holland, Christy K.
2013-01-01
Using an FDA-approved contrast agent (Definity®) and thrombolytic drug (rt-PA), we investigated ultrasound-enhanced thrombolysis in two whole-blood clot models. Porcine venous blood was collected from donor hogs and coagulated in two different materials. This method produced clots with differing compositional properties, as determined by routine scanning electron microscopy and histology. Clots were deployed in an ex vivo porcine thrombolysis model, while an intermittent ultrasound scheme previously developed to maximize stable cavitation was applied and acoustic emissions were detected. Exposure of clots to 3.15 μg/mL rt-PA promoted lysis in both clot models, compared to exposure to plasma alone. However, in the presence of rt-PA, Definity®, and ultrasound, only unretracted clots experienced significant enhancement of thrombolysis compared to treatment with rt-PA. In these clots, microscopy studies revealed loose erythrocyte aggregates, a significantly less extensive fibrin network, and a higher porosity, which may facilitate increase penetration of thrombolytics by cavitation. PMID:23453629
Analysis of Waveform Retracking Methods in Antarctic Ice Sheet Based on CRYOSAT-2 Data
NASA Astrophysics Data System (ADS)
Xiao, F.; Li, F.; Zhang, S.; Hao, W.; Yuan, L.; Zhu, T.; Zhang, Y.; Zhu, C.
2017-09-01
Satellite altimetry plays an important role in many geoscientific and environmental studies of Antarctic ice sheet. The ranging accuracy is degenerated near coasts or over nonocean surfaces, due to waveform contamination. A postprocess technique, known as waveform retracking, can be used to retrack the corrupt waveform and in turn improve the ranging accuracy. In 2010, the CryoSat-2 satellite was launched with the Synthetic aperture Interferometric Radar ALtimeter (SIRAL) onboard. Satellite altimetry waveform retracking methods are discussed in the paper. Six retracking methods including the OCOG method, the threshold method with 10 %, 25 % and 50 % threshold level, the linear and exponential 5-β parametric methods are used to retrack CryoSat-2 waveform over the transect from Zhongshan Station to Dome A. The results show that the threshold retracker performs best with the consideration of waveform retracking success rate and RMS of retracking distance corrections. The linear 5-β parametric retracker gives best waveform retracking precision, but cannot make full use of the waveform data.
Waveform shape analysis: extraction of physiologically relevant information from Doppler recordings.
Ramsay, M M; Broughton Pipkin, F; Rubin, P C; Skidmore, R
1994-05-01
1. Doppler recordings were made from the brachial artery of healthy female subjects during a series of manoeuvres which altered the pressure-flow characteristics of the vessel. 2. Changes were induced in the peripheral circulation of the forearm by the application of heat or ice-packs. A sphygmomanometer cuff was used to create graded occlusion of the vessel above and below the point of measurement. Recordings were also made whilst the subjects performed a standardized Valsalva manoeuvre. 3. The Doppler recordings were analysed both with the standard waveform indices (systolic/diastolic ratio, pulsatility index and resistance index) and by the method of Laplace transform analysis. 4. The waveform parameters obtained by Laplace transform analysis distinguished the different changes in flow conditions; they thus had direct physiological relevance, unlike the standard waveform indices.
Radial artery pulse waveform analysis based on curve fitting using discrete Fourier series.
Jiang, Zhixing; Zhang, David; Lu, Guangming
2018-04-19
Radial artery pulse diagnosis has been playing an important role in traditional Chinese medicine (TCM). For its non-invasion and convenience, the pulse diagnosis has great significance in diseases analysis of modern medicine. The practitioners sense the pulse waveforms in patients' wrist to make diagnoses based on their non-objective personal experience. With the researches of pulse acquisition platforms and computerized analysis methods, the objective study on pulse diagnosis can help the TCM to keep up with the development of modern medicine. In this paper, we propose a new method to extract feature from pulse waveform based on discrete Fourier series (DFS). It regards the waveform as one kind of signal that consists of a series of sub-components represented by sine and cosine (SC) signals with different frequencies and amplitudes. After the pulse signals are collected and preprocessed, we fit the average waveform for each sample using discrete Fourier series by least squares. The feature vector is comprised by the coefficients of discrete Fourier series function. Compared with the fitting method using Gaussian mixture function, the fitting errors of proposed method are smaller, which indicate that our method can represent the original signal better. The classification performance of proposed feature is superior to the other features extracted from waveform, liking auto-regression model and Gaussian mixture model. The coefficients of optimized DFS function, who is used to fit the arterial pressure waveforms, can obtain better performance in modeling the waveforms and holds more potential information for distinguishing different psychological states. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Biswas, Deblina; Vasudevan, Srivathsan; Chen, George C. K.; Sharma, Norman
2017-02-01
Formation of blood clots, called thrombus, can happen due to hyper-coagulation of blood. Thrombi, while moving through blood vessels can impede blood flow, an important criterion for many critical diseases like deep vein thrombosis and heart attacks. Understanding mechanical properties of clot formation is vital for assessment of severity of thrombosis and proper treatment. However, biomechanics of thrombus is less known to clinicians and not very well investigated. Photoacoustic (PA) spectral response, a non-invasive technique, is proposed to investigate the mechanism of formation of blood clots through elasticity and also differentiate clots from blood. Distinct shift (increase in frequency) of the PA response dominant frequency during clot formation is reported. In addition, quantitative differentiation of blood clots from blood has been achieved through parameters like dominant frequency and spectral energy of PA spectral response. Nearly twofold increases in dominant frequency in blood clots compared to blood were found in the PA spectral response. Significant changes in energy also help in quantitatively differentiating clots from blood, in the blood. Our results reveal that increase in density during clot formation is reflected in the PA spectral response, a significant step towards understanding the mechanobiology of thrombus formation. Hence, the proposed tool, in addition to detecting thrombus formation, could reveal mechanical properties of the sample through quantitative photoacoustic spectral parameters.
Vukasović, Andreja; Ivković, Alan; Jezek, Davor; Cerovecki, Ivan; Vnuk, Drazen; Kreszinger, Mario; Hudetz, Damir; Pećina, Marko
2011-01-01
Articular cartilage is an avascular and aneural tissue lacking lymph drainage, hence its inability of spontaneous repair following injury. Thus, it offers an interesting model for scientific research. A number of methods have been suggested to enhance cartilage repair, but none has yet produced significant success. The possible application of the aforementioned methods has brought about the necessity to evaluate their results. The objective of this study was to analyze results of a study of the effects of the use of TGF-beta gene transduced bone marrow clot on articular cartilage defects using ICRS visual histological assessment scale. The research was conducted on 28 skeletally mature sheep that were randomly assigned to four groups and surgically inflicted femoral chondral defects. The articular surfaces were then treated with TGF-beta1 gene transduced bone marrow clot (TGF group), GFP transduced bone marrow clot (GFP group), untransduced bone marrow clot (BM group) or left untreated (NC group). The analysis was performed by visual examination of cartilage samples and results were obtained using ICRS visual histological assessment scale. The results were subsequently subjected to statistical assessment using Kruskal-Wallis and Mann-Whitney tests. Kruskal-Wallis test yielded statistically significant difference with respect to cell distribution. Mann-Whitney test showed statistically significant difference between TGF and NC groups (P = 0.002), as well as between BM and NC groups (P = 0.002 with Bonferroni correction). Twenty-six of the twenty-eight samples were subjected to histologic and subsequent statistical analysis; two were discarded due to faulty histology technique. Our results indicated a level of certainty as to the positive effect of TGF-beta1 gene transduced bone marrow clot in restoration of articular cartilage defects. However, additional research is necessary in the field. One of the significant drawbacks on histologic assessment of cartilage samples were the errors in histologic preparation, for which some samples had to be discarded and significantly impaired the analytical quality of the others. Defects of structures surrounding the articular cartilage, e.g., subchondral bone or connective tissue, might also impair the quality of histologic analysis. Additional analyses, i.e. polarizing microscopy should be performed to determine the degree of integration of the newly formed tissue with the surrounding cartilage. The semiquantitative ICRS scale, although of great practical value, has limitations as to the objectivity of the assessment, taking into account the analytical ability of the evaluator, as well as the accuracy of semiquantitative analysis in comparison to the methods of quantitative analysis. Overall results of histologic analysis indicated that the application of TGF-beta1 gene transduced bone marrow clot could have measurable clinical effects on articular cartilage repair. The ICRS visual histological assessment scale is a valuable analytical method for cartilage repair evaluation. In this respect, further analyses of the method value would be of great importance.
Histotripsy Thrombolysis on Retracted Clots
Zhang, Xi; Owens, Gabe E.; Cain, Charles A.; Gurm, Hitinder S.; Macoskey, Jonathan; Xu, Zhen
2016-01-01
Retracted blood clots have been previously recognized to be more resistant to drug-based thrombolysis methods, even with ultrasound and microbubble enhancements. Microtripsy, a new histotripsy approach, has been investigated as a non-invasive, drug-free, and image-guided method that uses ultrasound to break up clots with improved treatment accuracy and a lower risk of vessel damage when compared to the traditional histotripsy thrombolysis approach. Unlike drug-mediated thrombolysis, which is dependent on the permeation of the thrombolytic agents into the clot, microtripsy controls acoustic cavitation to fractionate clots. We hypothesize that microtripsy thrombolysis is effective on retracted clots and that the treatment efficacy can be enhanced using strategies incorporating electronic focal steering. To test our hypothesis, retracted clots were prepared in vitro and the mechanical properties were quantitatively characterized. Microtripsy thrombolysis was applied on the retracted clots in an in vitro flow model using three different strategies: single-focus, electronically-steered multi-focus, and a dual-pass multi-focus strategy. Results show that microtripsy was used to successfully generate a flow channel through the retracted clot and the flow was restored. The multi-focus and the dual-pass treatments incorporating the electronic focal steering significantly increased the recanalized flow channel size compared to the single-focus treatments. The dual-pass treatments achieved a restored flow rate up to 324 mL/min without cavitation contacting the vessel wall. The clot debris particles generated from microtripsy thrombolysis remained within the safe range. The results in this study show the potential of microtripsy thrombolysis for retracted clot recanalization with the enhancement of electronic focal steering. PMID:27166017
Clots Are Potent Triggers of Inflammatory Cell Gene Expression: Indications for Timely Fibrinolysis.
Campbell, Robert A; Vieira-de-Abreu, Adriana; Rowley, Jesse W; Franks, Zechariah G; Manne, Bhanu Kanth; Rondina, Matthew T; Kraiss, Larry W; Majersik, Jennifer J; Zimmerman, Guy A; Weyrich, Andrew S
2017-10-01
Blood vessel wall damage often results in the formation of a fibrin clot that traps inflammatory cells, including monocytes. The effect of clot formation and subsequent lysis on the expression of monocyte-derived genes involved in the development and progression of ischemic stroke and other vascular diseases, however, is unknown. Determine whether clot formation and lysis regulates the expression of human monocyte-derived genes that modulate vascular diseases. We performed next-generation RNA sequencing on monocytes extracted from whole blood clots and using a purified plasma clot system. Numerous mRNAs were differentially expressed by monocytes embedded in clots compared with unclotted controls, and IL-8 (interleukin 8) and MCP-1 (monocyte chemoattractant protein-1) were among the upregulated transcripts in both models. Clotted plasma also increased expression of IL-8 and MCP-1, which far exceeded responses observed in lipopolysaccharide-stimulated monocytes. Upregulation of IL-8 and MCP-1 occurred in a thrombin-independent but fibrin-dependent manner. Fibrinolysis initiated shortly after plasma clot formation (ie, 1-2 hours) reduced the synthesis of IL-8 and MCP-1, whereas delayed fibrinolysis was far less effective. Consistent with these in vitro models, monocytes embedded in unresolved thrombi from patients undergoing thrombectomy stained positively for IL-8 and MCP-1. These findings demonstrate that clots are potent inducers of monocyte gene expression and that timely fibrinolysis attenuates inflammatory responses, specifically IL-8 and MCP-1. Dampening of inflammatory gene expression by timely clot lysis may contribute to the clinically proven efficacy of fibrinolytic drug treatment within hours of stroke onset. © 2017 American Heart Association, Inc.
21 CFR 864.7140 - Activated whole blood clotting time tests.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Activated whole blood clotting time tests. 864....7140 Activated whole blood clotting time tests. (a) Identification. An activated whole blood clotting... pulmonary embolism by measuring the coagulation time of whole blood. (b) Classification. Class II...
21 CFR 864.7140 - Activated whole blood clotting time tests.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Activated whole blood clotting time tests. 864....7140 Activated whole blood clotting time tests. (a) Identification. An activated whole blood clotting... pulmonary embolism by measuring the coagulation time of whole blood. (b) Classification. Class II...
21 CFR 864.7140 - Activated whole blood clotting time tests.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Activated whole blood clotting time tests. 864....7140 Activated whole blood clotting time tests. (a) Identification. An activated whole blood clotting... pulmonary embolism by measuring the coagulation time of whole blood. (b) Classification. Class II...
21 CFR 864.7140 - Activated whole blood clotting time tests.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Activated whole blood clotting time tests. 864....7140 Activated whole blood clotting time tests. (a) Identification. An activated whole blood clotting... pulmonary embolism by measuring the coagulation time of whole blood. (b) Classification. Class II...
21 CFR 864.7140 - Activated whole blood clotting time tests.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Activated whole blood clotting time tests. 864....7140 Activated whole blood clotting time tests. (a) Identification. An activated whole blood clotting... pulmonary embolism by measuring the coagulation time of whole blood. (b) Classification. Class II...
21 CFR 173.150 - Milk-clotting enzymes, microbial.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Milk-clotting enzymes, microbial. 173.150 Section... HUMAN CONSUMPTION Enzyme Preparations and Microorganisms § 173.150 Milk-clotting enzymes, microbial. Milk-clotting enzyme produced by pure-culture fermentation process may be safely used in the production...
21 CFR 173.150 - Milk-clotting enzymes, microbial.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Milk-clotting enzymes, microbial. 173.150 Section... HUMAN CONSUMPTION Enzyme Preparations and Microorganisms § 173.150 Milk-clotting enzymes, microbial. Milk-clotting enzyme produced by pure-culture fermentation process may be safely used in the production...
21 CFR 173.150 - Milk-clotting enzymes, microbial.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Milk-clotting enzymes, microbial. 173.150 Section... (CONTINUED) SECONDARY DIRECT FOOD ADDITIVES PERMITTED IN FOOD FOR HUMAN CONSUMPTION Enzyme Preparations and Microorganisms § 173.150 Milk-clotting enzymes, microbial. Milk-clotting enzyme produced by pure-culture...
21 CFR 173.150 - Milk-clotting enzymes, microbial.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Milk-clotting enzymes, microbial. 173.150 Section... HUMAN CONSUMPTION Enzyme Preparations and Microorganisms § 173.150 Milk-clotting enzymes, microbial. Milk-clotting enzyme produced by pure-culture fermentation process may be safely used in the production...
2007-09-01
waveforms recorded at St. George, Utah, from the Texarkana event. Figure 6. Recorded infrasound waveforms at one of the SGAR array elements...along with its spectrogram, from the Texarkana underground nuclear explosion of February 10, 1989. Preliminary Analysis of Waveform Parameters Related
Gas stream analysis using voltage-current time differential operation of electrochemical sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woo, Leta Yar-Li; Glass, Robert Scott; Fitzpatrick, Joseph Jay
A method for analysis of a gas stream. The method includes identifying an affected region of an affected waveform signal corresponding to at least one characteristic of the gas stream. The method also includes calculating a voltage-current time differential between the affected region of the affected waveform signal and a corresponding region of an original waveform signal. The affected region and the corresponding region of the waveform signals have a sensitivity specific to the at least one characteristic of the gas stream. The method also includes generating a value for the at least one characteristic of the gas stream basedmore » on the calculated voltage-current time differential.« less
Fluid Mechanics of Blood Clot Formation.
Fogelson, Aaron L; Neeves, Keith B
2015-01-01
Intravascular blood clots form in an environment in which hydrodynamic forces dominate and in which fluid-mediated transport is the primary means of moving material. The clotting system has evolved to exploit fluid dynamic mechanisms and to overcome fluid dynamic challenges to ensure that clots that preserve vascular integrity can form over the wide range of flow conditions found in the circulation. Fluid-mediated interactions between the many large deformable red blood cells and the few small rigid platelets lead to high platelet concentrations near vessel walls where platelets contribute to clotting. Receptor-ligand pairs with diverse kinetic and mechanical characteristics work synergistically to arrest rapidly flowing cells on an injured vessel. Variations in hydrodynamic stresses switch on and off the function of key clotting polymers. Protein transport to, from, and within a developing clot determines whether and how fast it grows. We review ongoing experimental and modeling research to understand these and related phenomena.
Fluid Mechanics of Blood Clot Formation
NASA Astrophysics Data System (ADS)
Fogelson, Aaron L.; Neeves, Keith B.
2015-01-01
Intravascular blood clots form in an environment in which hydrodynamic forces dominate and in which fluid-mediated transport is the primary means of moving material. The clotting system has evolved to exploit fluid dynamic mechanisms and to overcome fluid dynamic challenges to ensure that clots that preserve vascular integrity can form over the wide range of flow conditions found in the circulation. Fluid-mediated interactions between the many large deformable red blood cells and the few small rigid platelets lead to high platelet concentrations near vessel walls where platelets contribute to clotting. Receptor-ligand pairs with diverse kinetic and mechanical characteristics work synergistically to arrest rapidly flowing cells on an injured vessel. Variations in hydrodynamic stresses switch on and off the function of key clotting polymers. Protein transport to, from, and within a developing clot determines whether and how fast it grows. We review ongoing experimental and modeling research to understand these and related phenomena.
[Contraction (retraction) of blood clots in patients with ischemic stroke].
Peshkova, A D; Saikhunov, M V; Demin, T V; Lozhkin, A P; Panasyuk, M V; Litvinov, R I; Khasanova, D R
2016-01-01
To study a possible pathogenetic role of the blood clot contraction and its disturbances in the acute stage of ischemic stroke (IS). Using a new instrumental technique to study the dynamics of clot contraction in vitro, the authors have determined quantitative parameters of clot contraction (the extent and rate of contraction, duration of the lag-period) in the blood of 85 patients with acute IS. The contractile activity of blood clots was substantially reduced compared to the blood of healthy subjects. Correlations between hemostatic and contractile parameters suggest that the reduced clot contraction in stroke is due to the lower platelet count and impaired platelet functionality, higher levels of fibrinogen and antithrombin III as well as higher hematocrit and hemoglobin contents, leukocytosis, and changes in the biochemical blood composition. The results show that the reduced ability of clots may be a novel pathogenic mechanism that aggravates the course and outcomes of IS.
Fibrin Clots Are Equilibrium Polymers That Can Be Remodeled Without Proteolytic Digestion
NASA Astrophysics Data System (ADS)
Chernysh, Irina N.; Nagaswami, Chandrasekaran; Purohit, Prashant K.; Weisel, John W.
2012-11-01
Fibrin polymerization is a necessary part of hemostasis but clots can obstruct blood vessels and cause heart attacks and strokes. The polymerization reactions are specific and controlled, involving strong knob-into-hole interactions to convert soluble fibrinogen into insoluble fibrin. It has long been assumed that clots and thrombi are stable structures until proteolytic digestion. On the contrary, using the technique of fluorescence recovery after photobleaching, we demonstrate here that there is turnover of fibrin in an uncrosslinked clot. A peptide representing the knobs involved in fibrin polymerization can compete for the holes and dissolve a preformed fibrin clot, or increase the fraction of soluble oligomers, with striking rearrangements in clot structure. These results imply that in vivo clots or thrombi are more dynamic structures than previously believed that may be remodeled as a result of local environmental conditions, may account for some embolization, and suggest a target for therapeutic intervention.
Porcine pilot study of MRI-guided HIFU treatment for neonatal intraventricular hemorrhage (IVH)
NASA Astrophysics Data System (ADS)
Looi, Thomas; Waspe, Adam; Mougenot, Charles; Amaral, Joao; Temple, Michael; Hynynen, Kullervo; Drake, James
2012-11-01
Intraventricular hemorrhage (IVH) occurs in 15% of premature babies and 50% of IVH cases progress to posthemorrhagic ventricular dilation due to large blood clots forming in the ventricles. Existing treatments such as tissue plasminogen activator (tPA) and surgical intervention have severe side effects in paediatric patients that include excessive bleeding and complications. This study investigates the feasibility of MR-HIFU for sonothrombolysis of blood clots from IVH using natural acoustic windows, known as fontanelles, in the skulls of newborns. The study involved 2 elements: a phantom study to examine beam limitations and acoustic properties, and an in-vivo porcine study. A phantom skull was created from sample patient data and was used to analyze reachability of the Philips Sonavelle system. Acoustic measurements of the phantom (attenuation of 5-14 dB and speed of sound of 1722-2965 m/s) indicated the phantom effectively mimics neonatal skull bone. For the ex-vivo studies, a porcine clot was created and sonicated for 5 mins at 500W with a 0.5% duty cycle. For the in-vivo experiment, a vertex craniotomy was performed and porcine blood was injected into the lateral ventricle under ultrasound guidance. Sonication using the prior parameters induced cavitation and post-sonication T1 and T2 images verified clot lysis. Further H&E analysis showed no presence of blood in the ventricles. These positive results show that MR-HIFU has potential as a noninvasive tool for sonothrombolysis of neonatal IVH clots.
A computer system for analysis and transmission of spirometry waveforms using volume sampling.
Ostler, D V; Gardner, R M; Crapo, R O
1984-06-01
A microprocessor-controlled data gathering system for telemetry and analysis of spirometry waveforms was implemented using a completely digital design. Spirometry waveforms were obtained from an optical shaft encoder attached to a rolling seal spirometer. Time intervals between 10-ml volume changes (volume sampling) were stored. The digital design eliminated problems of analog signal sampling. The system measured flows up to 12 liters/sec with 5% accuracy and volumes up to 10 liters with 1% accuracy. Transmission of 10 waveforms took about 3 min. Error detection assured that no data were lost or distorted during transmission. A pulmonary physician at the central hospital reviewed the volume-time and flow-volume waveforms and interpretations generated by the central computer before forwarding the results and consulting with the rural physician. This system is suitable for use in a major hospital, rural hospital, or small clinic because of the system's simplicity and small size.
NASA Astrophysics Data System (ADS)
Li, Xuelong; Li, Zhonghui; Wang, Enyuan; Feng, Junjun; Chen, Liang; Li, Nan; Kong, Xiangguo
2016-09-01
This study provides a new research idea concerning rock burst prediction. The characteristics of microseismic (MS) waveforms prior to and during the rock burst were studied through the Hilbert-Huang transform (HHT). In order to demonstrate the advantage of the MS features extraction based on HHT, the conventional analysis method (Fourier transform) was also used to make a comparison. The results show that HHT is simple and reliable, and could extract in-depth information about the characteristics of MS waveforms. About 10 days prior to the rock burst, the main frequency of MS waveforms transforms from the high-frequency to low-frequency. What's more, the waveforms energy also presents accumulation characteristic. Based on our study results, it can be concluded that the MS signals analysis through HHT could provide valuable information about the coal or rock deformation and fracture.
Sakai, Yuji; Tsuyuguchi, Toshio; Sugiyama, Harutoshi; Nishikawa, Takao; Kurosawa, Jo; Saito, Masayoshi; Tawada, Katsunobu; Mikata, Rintaro; Tada, Motohisa; Ishihara, Takeshi; Yokosuka, Osamu
2013-08-01
Bleeding following endoscopic sphincterotomy (EST) is a rare but unavoidable complication of the procedure. We routinely perform local injection of hypertonic saline-epinephrine (HSE) for the treatment of post-EST bleeding. Any blood clot is removed only by irrigation with water after local injection of pure ethanol into the blood clot to cause crusting. We evaluated the usefulness of this treatment method. Subjects were 8 patients (1.2%) with post-EST bleeding requiring hemostatic intervention among 682 patients undergoing EST. After determination of the bleeding point, local injection of HSE was performed. When an adherent blood clot was present, pure ethanol was injected into the blood clot and then irrigation with water was performed to remove the blood clot. Endoscopic hemostasis was successfully achieved in all the 8 patients (100%). In 4 patients (50%), the adherent blood clots were successfully removed only with pure ethanol local injection into the blood clot followed by irrigation with water. No complications of the hemostatic procedure occurred in any patients. This study indicated that hemostasis with HSE local injection can be safe and useful for the treatment of post-EST bleeding, and also that blood clot removal with pure ethanol local injection can be useful.
Acousto-mechanical and thermal properties of clotted blooda)
Nahirnyak, Volodymyr M.; Yoon, Suk Wang; Holland, Christy K.
2007-01-01
The efficacy of ultrasound-assisted thrombolysis as an adjunct treatment of ischemic stroke is being widely investigated. To determine the role of ultrasound hyperthermia in the process of blood clot disruption, the acousto-mechanical and thermal properties of clotted blood were measured in vitro, namely, density, speed of sound, frequency-dependent attenuation, specific heat, and thermal conductivity. The amplitude coefficient of attenuation of the clots was determined for 120 kHz, 1.0 MHz, and 3.5 MHz ultrasound at room temperature (20±2 °C). The attenuation coefficient ranged from 0.10 to 0.30 Np/cm in porcine clots and from 0.09 to 0.23 Np/cm in human clots. The experimentally determined values of specific heat and thermal conductivity for porcine clotted blood are (3.2±0.5)×103 J/kg·K and 0.55±0.13 W/m·K, respectively, and for human clotted blood are (3.5±0.8)×103 J/kg·K and 0.59±0.11 W/m·K, respectively. Measurements of the acousto-mechanical and thermal properties of clotted blood can be helpful in theoretical modeling of ultrasound hyperthermia in ultrasound-assisted thrombolysis and other high-intensity focused ultrasound applications. PMID:16838520
ClotChip: A Microfluidic Dielectric Sensor for Point-of-Care Assessment of Hemostasis.
Maji, Debnath; Suster, Michael A; Kucukal, Erdem; Sekhon, Ujjal D S; Gupta, Anirban Sen; Gurkan, Umut A; Stavrou, Evi X; Mohseni, Pedram
2017-12-01
This paper describes the design, fabrication, and testing of a microfluidic sensor for dielectric spectroscopy of human whole blood during coagulation. The sensor, termed ClotChip, employs a three-dimensional, parallel-plate, capacitive sensing structure with a floating electrode integrated into a microfluidic channel. Interfaced with an impedance analyzer, the ClotChip measures the complex relative dielectric permittivity, ϵ r , of human whole blood in the frequency range of 40 Hz to 100 MHz. The temporal variation in the real part of the blood dielectric permittivity at 1 MHz features a time to reach a permittivity peak, , as well as a maximum change in permittivity after the peak, , as two distinct parameters of ClotChip readout. The ClotChip performance was benchmarked against rotational thromboelastometry (ROTEM) to evaluate the clinical utility of its readout parameters in capturing the clotting dynamics arising from coagulation factors and platelet activity. exhibited a very strong positive correlation ( r = 0.99, p < 0.0001) with the ROTEM clotting time parameter, whereas exhibited a strong positive correlation (r = 0.85, p < 0.001) with the ROTEM maximum clot firmness parameter. This paper demonstrates the ClotChip potential as a point-of-care platform to assess the complete hemostatic process using <10 μL of human whole blood.
2014-03-01
waveforms that are easier to measure than ABP (e.g., pulse oximeter waveforms); (3) a NIH SBIR Phase I proposal with Retia Medical to develop automated...the training dataset. Integrating the technique with non-invasive pulse transit time (PTT) was most effective. The integrated technique specifically...the peripheral ABP waveforms in the training dataset. These techniques included the rudimentary mean ABP technique, the classic pulse pressure times
Abraham, Libin; Kapopara, Piyushkumar R.; Lai, Benjamin F. L.; Shenoi, Rajesh A.; Rosell, Federico I.; Conway, Edward M.; Pryzdial, Edward L. G.; Haynes, Charles A.
2017-01-01
Anticoagulant therapy–associated bleeding and pathological thrombosis pose serious risks to hospitalized patients. Both complications could be mitigated by developing new therapeutics that safely neutralize anticoagulant activity and inhibit activators of the intrinsic blood clotting pathway, such as polyphosphate (polyP) and extracellular nucleic acids. The latter strategy could reduce the use of anticoagulants, potentially decreasing bleeding events. However, previously described cationic inhibitors of polyP and extracellular nucleic acids exhibit both nonspecific binding and adverse effects on blood clotting that limit their use. Indeed, the polycation used to counteract heparin-associated bleeding in surgical settings, protamine, exhibits adverse effects. To address these clinical shortcomings, we developed a synthetic polycation, Universal Heparin Reversal Agent (UHRA), which is nontoxic and can neutralize the anticoagulant activity of heparins and the prothrombotic activity of polyP. Sharply contrasting protamine, we show that UHRA does not interact with fibrinogen, affect fibrin polymerization during clot formation, or abrogate plasma clotting. Using scanning electron microscopy, confocal microscopy, and clot lysis assays, we confirm that UHRA does not incorporate into clots, and that clots are stable with normal fibrin morphology. Conversely, protamine binds to the fibrin clot, which could explain how protamine instigates clot lysis and increases bleeding after surgery. Finally, studies in mice reveal that UHRA reverses heparin anticoagulant activity without the lung injury seen with protamine. The data presented here illustrate that UHRA could be safely used as an antidote during adverse therapeutic modulation of hemostasis. PMID:28034889
Histotripsy Thrombolysis on Retracted Clots.
Zhang, Xi; Owens, Gabe E; Cain, Charles A; Gurm, Hitinder S; Macoskey, Jonathan; Xu, Zhen
2016-08-01
Retracted blood clots have been previously recognized to be more resistant to drug-based thrombolysis methods, even with ultrasound and microbubble enhancements. Microtripsy, a new histotripsy approach, has been investigated as a non-invasive, drug-free and image-guided method that uses ultrasound to break up clots with improved treatment accuracy and a lower risk of vessel damage compared with the traditional histotripsy thrombolysis approach. Unlike drug-mediated thrombolysis, which is dependent on the permeation of the thrombolytic agents into the clot, microtripsy controls acoustic cavitation to fractionate clots. We hypothesize that microtripsy thrombolysis is effective on retracted clots and that the treatment efficacy can be enhanced using strategies incorporating electronic focal steering. To test our hypothesis, retracted clots were prepared in vitro and the mechanical properties were quantitatively characterized. Microtripsy thrombolysis was applied on the retracted clots in an in vitro flow model using three different strategies: single-focus, electronically-steered multi-focus and dual-pass multi-focus. Results show that microtripsy was used to successfully generate a flow channel through the retracted clot and the flow was restored. The multi-focus and the dual-pass treatments incorporating the electronic focal steering significantly increased the recanalized flow channel size compared to the single-focus treatments. The dual-pass treatments achieved a restored flow rate up to 324 mL/min without cavitation contacting the vessel wall. The clot debris particles generated from microtripsy thrombolysis remained within the safe range. The results of this study show the potential of microtripsy thrombolysis for retracted clot recanalization with the enhancement of electronic focal steering. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Muthard, Ryan W.; Welsh, John D.; Brass, Lawrence F.; Diamond, Scott L.
2015-01-01
SUMMARY Objective Biological and physical factors interact to modulate blood response in a wounded vessel, resulting in a hemostatic clot or an occlusive thrombus. Flow and pressure differential (ΔP) across the wound from the lumen to the extravascular compartment may impact hemostasis and the observed core/shell architecture. We examined physical and biological factors responsible for regulating thrombin mediated clot growth. Approach and Results Using factor XIIa-inhibited human whole blood perfused in a microfluidic device over collagen/tissue factor at controlled wall shear rate and ΔP, we found thrombin to be highly localized in the P-selectin+ core of hemostatic clots. Increasing ΔP from 9 to 29 mm-Hg (wall shear rate = 400 s−1) reduced P-selectin+ core size and total clot size due to enhanced extravasation of thrombin. Blockade of fibrin polymerization with 5 mM GPRP dysregulated hemostasis by enhancing both P-selectin+ core size and clot size at 400 s−1 (20 mm-Hg). For whole blood flow (no GPRP), the thickness of the P-selectin-negative shell was reduced under arterial conditions (2000 s−1, 20 mm-Hg). Consistent with the antithrombin-1 activity of fibrin implicated with GPRP, anti-γ’-fibrinogen antibody enhanced core-localized thrombin, core size, and overall clot size, especially at venous (100 s−1) but not arterial wall shear rates (2000 s−1). Pathological shear (15,000 s−1) and GPRP synergized to exacerbate clot growth. Conclusions Hemostatic clotting was dependent on core-localized thrombin that (1) triggered platelet P-selectin display and (2) was highly regulated by fibrin and the trans-clot ΔP. Also, γ’-fibrinogen had a role in venous but not arterial conditions. PMID:25614284
Liang, Xiaojun; Chernysh, Irina; Purohit, Prashant K; Weisel, John W
2017-09-15
Blood clots are required to stem bleeding and are subject to a variety of stresses, but they can also block blood vessels and cause heart attacks and ischemic strokes. We measured the compressive response of human platelet-poor plasma (PPP) clots, platelet-rich plasma (PRP) clots and whole blood clots and correlated these measurements with confocal and scanning electron microscopy to track changes in clot structure. Stress-strain curves revealed four characteristic regions, for compression-decompression: (1) linear elastic region; (2) upper plateau or softening region; (3) non-linear elastic region or re-stretching of the network; (4) lower plateau in which dissociation of some newly made connections occurs. Our experiments revealed that compression proceeds by the passage of a phase boundary through the clot separating rarefied and densified phases. This observation motivates a model of fibrin mechanics based on the continuum theory of phase transitions, which accounts for the pre-stress caused by platelets, the adhesion of fibrin fibers in the densified phase, the compression of red blood cells (RBCs), and the pumping of liquids through the clot during compression/decompression. Our experiments and theory provide insights into the mechanical behavior of blood clots that could have implications clinically and in the design of fibrin-based biomaterials. The objective of this paper is to measure and mathematically model the compression behavior of various human blood clots. We show by a combination of confocal and scanning electron microscopy that compression proceeds by the passage of a front through the sample that separates a densified region of the clot from a rarefied region, and that the compression/decompression response is reversible with hysteresis. These observations form the basis of a model for the compression response of clots based on the continuum theory of phase transitions. Our studies may reveal how clot rheology under large compression in vivo due to muscle contraction, platelet retraction and hydrodynamic flow varies under various pathophysiological conditions and could inform the design of fibrin based biomaterials. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Anomalous waveforms observed in laboratory-formed gas hydrate-bearing and ice-bearing sediments
Lee, Myung W.; Waite, William F.
2011-01-01
Acoustic transmission measurements of compressional, P, and shear, S, wave velocities rely on correctly identifying the P- and S-body wave arrivals in the measured waveform. In cylindrical samples for which the sample is much longer than the acoustic wavelength, these body waves can be obscured by high-amplitude waveform features arriving just after the relatively small-amplitude P-body wave. In this study, a normal mode approach is used to analyze this type of waveform, observed in sediment containing gas hydrate or ice. This analysis extends an existing normal-mode waveform propagation theory by including the effects of the confining medium surrounding the sample, and provides guidelines for estimating S-wave velocities from waveforms containing multiple large-amplitude arrivals. PMID:21476628
Pahlevan, Niema M; Rinderknecht, Derek G; Tavallali, Peyman; Razavi, Marianne; Tran, Thao T; Fong, Michael W; Kloner, Robert A; Csete, Marie; Gharib, Morteza
2017-07-01
The study is based on previously reported mathematical analysis of arterial waveform that extracts hidden oscillations in the waveform that we called intrinsic frequencies. The goal of this clinical study was to compare the accuracy of left ventricular ejection fraction derived from intrinsic frequencies noninvasively versus left ventricular ejection fraction obtained with cardiac MRI, the most accurate method for left ventricular ejection fraction measurement. After informed consent, in one visit, subjects underwent cardiac MRI examination and noninvasive capture of a carotid waveform using an iPhone camera (The waveform is captured using a custom app that constructs the waveform from skin displacement images during the cardiac cycle.). The waveform was analyzed using intrinsic frequency algorithm. Outpatient MRI facility. Adults able to undergo MRI were referred by local physicians or self-referred in response to local advertisement and included patients with heart failure with reduced ejection fraction diagnosed by a cardiologist. Standard cardiac MRI sequences were used, with periodic breath holding for image stabilization. To minimize motion artifact, the iPhone camera was held in a cradle over the carotid artery during iPhone measurements. Regardless of neck morphology, carotid waveforms were captured in all subjects, within seconds to minutes. Seventy-two patients were studied, ranging in age from 20 to 92 years old. The main endpoint of analysis was left ventricular ejection fraction; overall, the correlation between ejection fraction-iPhone and ejection fraction-MRI was 0.74 (r = 0.74; p < 0.0001; ejection fraction-MRI = 0.93 × [ejection fraction-iPhone] + 1.9). Analysis of carotid waveforms using intrinsic frequency methods can be used to document left ventricular ejection fraction with accuracy comparable with that of MRI. The measurements require no training to perform or interpret, no calibration, and can be repeated at the bedside to generate almost continuous analysis of left ventricular ejection fraction without arterial cannulation.
A system for rapid analysis of the femoral blood velocity waveform at the bedside.
Capper, W L; Amoore, J N; Clifford, P C; Immelman, E J; Harries-Jones, E P
1986-01-01
The shape of the arterial blood velocity waveform varies with atherosclerotic disease and several methods of quantifying the shape in order to predict the severity of the disease have been described. These methods include pulsatility index, the Laplace transform method, and principal component analysis. This paper describes the development of a system which allows the operator to acquire, display, and store waveforms from each limb and then to quantify the waveforms at the bedside within a few minutes. The system includes a 10 MHz bi-directional Doppler unit, an instantaneous mean frequency processor, and an Apple II microcomputer fitted with an accelerator card. Both the Laplace transform parameters and the pulsatility index are computed and each result is printed in tabular form together with the averaged results of five waveforms from each limb. The printout is suitable for inclusion in the patient's folder. In initial clinical studies Laplace transform analysis exhibited a good correlation with aorto-iliac stenosis as assessed angiographically (R = 0.73 P less than 0.001 t test).
Use of the Kalman Filter for Aortic Pressure Waveform Noise Reduction
Lu, Hsiang-Wei; Wu, Chung-Che; Aliyazicioglu, Zekeriya; Kang, James S.
2017-01-01
Clinical applications that require extraction and interpretation of physiological signals or waveforms are susceptible to corruption by noise or artifacts. Real-time hemodynamic monitoring systems are important for clinicians to assess the hemodynamic stability of surgical or intensive care patients by interpreting hemodynamic parameters generated by an analysis of aortic blood pressure (ABP) waveform measurements. Since hemodynamic parameter estimation algorithms often detect events and features from measured ABP waveforms to generate hemodynamic parameters, noise and artifacts integrated into ABP waveforms can severely distort the interpretation of hemodynamic parameters by hemodynamic algorithms. In this article, we propose the use of the Kalman filter and the 4-element Windkessel model with static parameters, arterial compliance C, peripheral resistance R, aortic impedance r, and the inertia of blood L, to represent aortic circulation for generating accurate estimations of ABP waveforms through noise and artifact reduction. Results show the Kalman filter could very effectively eliminate noise and generate a good estimation from the noisy ABP waveform based on the past state history. The power spectrum of the measured ABP waveform and the synthesized ABP waveform shows two similar harmonic frequencies. PMID:28611850
Huang, Mingbo; Hu, Ding; Yu, Donglan; Zheng, Zhensheng; Wang, Kuijian
2011-12-01
Enhanced extracorporeal counterpulsation (EECP) information consists of both text and hemodynamic waveform data. At present EECP text information has been successfully managed through Web browser, while the management and sharing of hemodynamic waveform data through Internet has not been solved yet. In order to manage EECP information completely, based on the in-depth analysis of EECP hemodynamic waveform file of digital imaging and communications in medicine (DICOM) format and its disadvantages in Internet sharing, we proposed the use of the extensible markup language (XML), which is currently the Internet popular data exchange standard, as the storage specification for the sharing of EECP waveform data. Then we designed a web-based sharing system of EECP hemodynamic waveform data via ASP. NET 2.0 platform. Meanwhile, we specifically introduced the four main system function modules and their implement methods, including DICOM to XML conversion module, EECP waveform data management module, retrieval and display of EECP waveform module and the security mechanism of the system.
NASA Astrophysics Data System (ADS)
Sak, Mark; Duric, Neb; Littrup, Peter; Sherman, Mark; Gierach, Gretchen
2017-03-01
Ultrasound tomography (UST) is an emerging modality that can offer quantitative measurements of breast density. Recent breakthroughs in UST image reconstruction involve the use of a waveform reconstruction as opposed to a raybased reconstruction. The sound speed (SS) images that are created using the waveform reconstruction have a much higher image quality. These waveform images offer improved resolution and contrasts between regions of dense and fatty tissues. As part of a study that was designed to assess breast density changes using UST sound speed imaging among women undergoing tamoxifen therapy, UST waveform sound speed images were then reconstructed for a subset of participants. These initial results show that changes to the parenchymal tissue can more clearly be visualized when using the waveform sound speed images. Additional quantitative testing of the waveform images was also started to test the hypothesis that waveform sound speed images are a more robust measure of breast density than ray-based reconstructions. Further analysis is still needed to better understand how tamoxifen affects breast tissue.
NASA Astrophysics Data System (ADS)
Rodgers, Mel; Smith, Patrick; Pyle, David; Mather, Tamsin
2016-04-01
Understanding the transition between quiescence and eruption at dome-forming volcanoes, such as Soufrière Hills Volcano (SHV), Montserrat, is important for monitoring volcanic activity during long-lived eruptions. Statistical analysis of seismic events (e.g. spectral analysis and identification of multiplets via cross-correlation) can be useful for characterising seismicity patterns and can be a powerful tool for analysing temporal changes in behaviour. Waveform classification is crucial for volcano monitoring, but consistent classification, both during real-time analysis and for retrospective analysis of previous volcanic activity, remains a challenge. Automated classification allows consistent re-classification of events. We present a machine learning (random forest) approach to rapidly classify waveforms that requires minimal training data. We analyse the seismic precursors to the July 2008 Vulcanian explosion at SHV and show systematic changes in frequency content and multiplet behaviour that had not previously been recognised. These precursory patterns of seismicity may be interpreted as changes in pressure conditions within the conduit during magma ascent and could be linked to magma flow rates. Frequency analysis of the different waveform classes supports the growing consensus that LP and Hybrid events should be considered end members of a continuum of low-frequency source processes. By using both supervised and unsupervised machine-learning methods we investigate the nature of waveform classification and assess current classification schemes.
Hwang, Sung Ha; Yoo, Chungkwon; Kim, Yong Yeon; Lee, Dae Young; Nam, Dong Heun; Lee, Jong Yeon
2017-12-01
Glaucoma drainage implant surgery is a treatment option for the management of neovascular glaucoma. However, tube obstruction by blood clot after Ahmed glaucoma valve (AGV) implantation is an unpredictable clinically challenging situation. We report 4 cases using intracameral air injection for the prevention of the tube obstruction of AGV by blood clot. The first case was a 57-year-old female suffering from ocular pain because of a tube obstruction with blood clot after AGV implantation in neovascular glaucoma. Surgical blood clot removal was performed. However, intractable bleeding was noted during the removal of the blood clot, and so intracameral air injection was performed to prevent a recurrent tube obstruction. After the procedure, although blood clots formed around the tube, the tube opening where air could touch remained patent. In 3 cases of neovascular glaucoma with preoperative severe intraocular hemorrhages, intracameral air injection and AGV implantation were performed simultaneously. In all 3 cases, tube openings were patent. It appears that air impeded the blood clots formation in front of the tube opening. Intracameral air injection could be a feasible option to prevent tube obstruction of AGV implant with a blood clot in neovascular glaucoma with high risk of tube obstruction. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Wang, Caroline W; Perez, Matthew J; Helmke, Brian P; Viola, Francesco; Lawrence, Michael B
2015-01-01
Despite the life-preserving function blood clotting serves in the body, inadequate or excessive blood clot stiffness has been associated with life-threatening diseases such as stroke, hemorrhage, and heart attack. The relationship between blood clot stiffness and vascular diseases underscores the importance of quantifying the magnitude and kinetics of blood's transformation from a fluid to a viscoelastic solid. To measure blood plasma clot stiffness, we have developed a method that uses ultrasound acoustic radiation force (ARF) to induce micron-scaled displacements (1-500 μm) on microbeads suspended in blood plasma. The displacements were detected by optical microscopy and took place within a micro-liter sized clot region formed within a larger volume (2 mL sample) to minimize container surface effects. Modulation of the ultrasound generated acoustic radiation force allowed stiffness measurements to be made in blood plasma from before its gel point to the stage where it was a fully developed viscoelastic solid. A 0.5 wt % agarose hydrogel was 9.8-fold stiffer than the plasma (platelet-rich) clot at 1 h post-kaolin stimulus. The acoustic radiation force microbead method was sensitive to the presence of platelets and strength of coagulation stimulus. Platelet depletion reduced clot stiffness 6.9 fold relative to platelet rich plasma. The sensitivity of acoustic radiation force based stiffness assessment may allow for studying platelet regulation of both incipient and mature clot mechanical properties.
Implementation of the Domino Sampling Waveform digitizer in the PIBETA experiment
NASA Astrophysics Data System (ADS)
Wang, Ying
The Domino Sampling Chip(DSC)-Waveform digitization system is a significant addition to electronics arsenal of PIBETA experiment. It is used to digitize waveforms from every photo tube in the detector. Through carefully programmed offline analysis of its raw data collected during regular runtime, better timing and energy resolution are achieved compared with feast's results. And more importantly, the geometric character of the digitized waveform which contains information of energy deposition of particle decays can be utilized for particle identification, a great advantage that regular unit could not possess. In addition to fastbus, incorporate DSC data through its offline analysis including timing and energy offset, scale calibration will contribute a final more precise result of PIBETA experiment.
Lee, Hongyeul; Leem, Cho Sun; Lee, Jae Ho; Lee, Choon-Taek; Cho, Young-Jae
2014-10-01
Acute airway obstruction after hemoptysis occurs due to the presence of blood clots. These conditions may result in life-threatening ventilation impairment. We report a case of obstruction of the large airway by endobronchial blood clots which were removed using bronchoscopic cryotherapy at the bedside of intensive care unit. A 66-year-old female with endometrial cancer who had undergone chemotherapy, was admitted to the intensive care unit due to neutropenic fever. During mechanical ventilation, the minute ventilation dropped to inadequately low levels and chest radiography showed complete opacification of the left hemithorax. Flexible bronchoscopy revealed large blood clots obstructing the proximal left main bronchus. After unsuccessful attempts to remove the clots with bronchial lavage and forceps extraction, blood clots were removed using bronchoscopic cryotherapy. This report shows that cryotherapy via flexible bronchoscopy at the bedside in the intensive of intensive care unit is a simple and effective alternative for the removal of endobronchial blood clots.
Anomalous waveforms observed in laboratory-formed gas hydrate-bearing and ice-bearing sediments
Lee, M.W.; Waite, W.F.
2011-01-01
Acoustic transmission measurements of compressional, P, and shear, S, wave velocities rely on correctly identifying the P- and S-body wave arrivals in the measured waveform. In cylindrical samples for which the sample is much longer than the acoustic wavelength, these body waves can be obscured by high-amplitude waveform features arriving just after the relatively small-amplitude P-body wave. In this study, a normal mode approach is used to analyze this type of waveform, observed in sediment containing gas hydrate or ice. This analysis extends an existing normal-mode waveform propagation theory by including the effects of the confining medium surrounding the sample, and provides guidelines for estimating S-wave velocities from waveforms containing multiple large-amplitude arrivals. ?? 2011 Acoustical Society of America.
WaveformECG: A Platform for Visualizing, Annotating, and Analyzing ECG Data
Winslow, Raimond L.; Granite, Stephen; Jurado, Christian
2017-01-01
The electrocardiogram (ECG) is the most commonly collected data in cardiovascular research because of the ease with which it can be measured and because changes in ECG waveforms reflect underlying aspects of heart disease. Accessed through a browser, WaveformECG is an open source platform supporting interactive analysis, visualization, and annotation of ECGs. PMID:28642673
Wang, Lu; Xu, Lisheng; Feng, Shuting; Meng, Max Q-H; Wang, Kuanquan
2013-11-01
Analysis of pulse waveform is a low cost, non-invasive method for obtaining vital information related to the conditions of the cardiovascular system. In recent years, different Pulse Decomposition Analysis (PDA) methods have been applied to disclose the pathological mechanisms of the pulse waveform. All these methods decompose single-period pulse waveform into a constant number (such as 3, 4 or 5) of individual waves. Furthermore, those methods do not pay much attention to the estimation error of the key points in the pulse waveform. The estimation of human vascular conditions depends on the key points' positions of pulse wave. In this paper, we propose a Multi-Gaussian (MG) model to fit real pulse waveforms using an adaptive number (4 or 5 in our study) of Gaussian waves. The unknown parameters in the MG model are estimated by the Weighted Least Squares (WLS) method and the optimized weight values corresponding to different sampling points are selected by using the Multi-Criteria Decision Making (MCDM) method. Performance of the MG model and the WLS method has been evaluated by fitting 150 real pulse waveforms of five different types. The resulting Normalized Root Mean Square Error (NRMSE) was less than 2.0% and the estimation accuracy for the key points was satisfactory, demonstrating that our proposed method is effective in compressing, synthesizing and analyzing pulse waveforms. Copyright © 2013 Elsevier Ltd. All rights reserved.
The Navy Medical Technology Watch: Hemostatic Dressing Products for the Battlefield
2006-09-09
composition and ingredients, external bleeding cessation agents all work to help the rapid formation of a thrombus (clot) or other blockage at the...clotting agent Contraindicated for internal bleeding or deep tissue wounds Collagen. Collagen-like natural substances are created from chemically...2003) Experimental (swine) Complex groin injury, arterial, venous QuikClot produced 0% mortality; RDH had a 66% mortality rate. QuikClot
Ultrasound has synergistic effects in vitro with tirofiban and heparin for thrombus dissolution.
Birnbaum, Y; Atar, S; Luo, H; Nagai, T; Siegel, R J
1999-12-15
Previous studies have shown synergism between ultrasound and thrombolytic agents or microbubbles on blood clot dissolution. It has not been investigated whether heparin or glycoprotein IIb/IIIa blockers enhance clot lysis by ultrasound. We compared the blood clot dissolution effect of saline, heparin, tissue plasminogen activator (tPA), tirofiban, and an echocardiographic contrast media (Optison) without and with ultrasound application. Human blood clots from four donors, 2 to 4 hours old, were cut into 200- to 400-mg sections, weighed, and immersed for 2 minutes in 1 L of normal saline 0.9% solution containing either heparin 1000 U, tirofiban 150 microg, tPA 20 mg, Optison 0.5 mL, or normal saline alone. Clots were randomized to 2 minutes ultrasound application or immersion alone without ultrasound. Ultrasound was applied with a 19.5 KHz catheter. After treatment, the clots were weighed, and the absolute and percent difference in weight was calculated. Immersion in heparin, tirofiban, and tPA without ultrasound did not augment clot disruption relative to normal saline alone. Immersion in Optison (p = 0.07) tended to result in less lysis than saline alone. Ultrasound enhanced clot dissolution compared to immersion alone with: saline (48.1+/-15.3% vs. 26.0+/-13.8%, p<0.0000002); heparin (60.8+/-17.5% vs. 30.8+/-15.1%, p = 0.000001); tirofiban (61.8+/-13.6% vs. 30.1+/-12.2%, p<0.0000001); tPA (53.1+/-15.3% vs. 30.2+/-11.5%, p<0.000002); and Optison (47.8+/-16.0% vs. 18.4+/-11.5%, p<0.0000001). The combination of tirofiban with ultrasound, as well as heparin with ultrasound, was associated with a significant augmentation of clot dissolution compared with the saline plus ultrasound group (p = 0.002, 0.013, respectively). Ultrasound with tPA or with Optison had no significant augmentation of clot dissolution over the ultrasound + saline effect. This in vitro study of catheter-delivered high-intensity low-frequency ultrasound demonstrates that: (1) tirofiban and heparin, as well as perfluorocarbon microbubbles, augment clot dissolution by ultrasound; (2) augmentation of clot dissolution is evident even after only brief exposure of ultrasound and the drug studied.
2012-01-01
Background Low Frequency Vibro-Percussion (LFVP) assists clearance of thrombi in catheter systems and when applied to the heart and timed to diastole is known to enhance coronary flow. However LFVP on a clotted coronary like vessel given engagement over a chest wall sized barrier (to resemble non-invasive heart attack therapy) requires study. Methods One hour old clots (n=16) were dispensed within a flexible segment of Soft-Flo catheter (4 mm lumen), weighted, interfaced with Heparinized Saline (HS), secured atop a curved dampening base, and photographed. A ~4 cm meat slab was placed over the segment and randomized to receive intermittent LFVP (engaged, - disengaged at 1 second intervals), or no LFVP for 20 minutes. HS was pulsed (~120/80 mmHg), with the diastolic phase coordinated to match LFVP delivery. The segment was then re-photographed and aspirated of fluid to determine post clot weight. The trial was then repeated with 0.5 mls of Streptokinase (15,000 IU/100 microlitre) delivered ~ 2 cm upstream from the clot. Results LFVP - HS only samples (vs. controls) showed; a) development of clot length fluid channels absent in the control group (p < 0.0002); b) enhanced dissolved clot mixing scores ( 5.0 vs. 0.8, p < 2.8 E – 6); and c) increased percent clot dissolution (23.0% vs. 1.8% respectively, p < 8.5 E-6). LFVP - SK samples had a similar comparative clot disruptive profile, however fluid channels developed faster and percent clot dissolution more than doubled (51.0% vs. 3.0%, p< 9.8 E- 6). Conclusion Diastolic timed LFVP (50 Hz) engaged across a chest wall sized barrier enhances clot disruptive effects to an underlying coronary like system. PMID:23146079
Janion-Sadowska, Agnieszka; Natorska, Joanna; Siudut, Jakub; Ząbczyk, Michal; Stanisz, Andrzej; Undas, Anetta
2017-08-30
We sought to investigate whether the G20210A prothrombin mutation modifies plasma fibrin clot properties in patients after venous thromboembolism (VTE) and how rivaroxaban treatment affects these alterations. We studied 34 prothrombin mutation heterozygous carriers and sex- and age-matched 34 non-carriers, all at least three months since the first VTE episode, before and during treatment with rivaroxaban. Clot permeability (K s ) and clot lysis time (CLT) with or without elimination of thrombin activatable fibrinolysis inhibitor (TAFI) were assessed at baseline, 2-6 hours (h) after and 20-25 h after intake of rivaroxaban (20 mg/day). At baseline, the prothrombin mutation group formed denser clots (K s -12 %, p=0.0006) and had impaired fibrinolysis (CLT +14 %, p=0.004, and CLT-TAFI +13 %, p=0.03) compared with the no mutation group and were similar to those observed in 15 healthy unrelated prothrombin mutation carriers. The G20210A prothrombin mutation was the independent predictor for K s and CLT before rivaroxaban intake. At 2-6 h after rivaroxaban intake, clot properties improved in both G20210A carriers and non-carriers (K s +38 %, and +37 %, CLT -25 % and -25 %, CLT-TAFI -20 % and -24 %, respectively, all p<0.001), but those parameters were worse in the prothrombin mutation group (K s -12.8 %, CLT +17 %, CLT-TAFI +13 %, all p<0.001). Rivaroxaban concentration correlated with fibrin clot properties. After 20-25 h since rivaroxaban intake most clot properties returned to baseline. Rivaroxaban-related differences in clot structure were confirmed by scanning electron microscopy images. In conclusion, rivaroxaban treatment, though improves fibrin clot properties, cannot abolish more prothrombotic fibrin clot phenotype observed in prothrombin mutation carriers following VTE.
In vitro evaluation of clot capture efficiency of an absorbable vena cava filter.
Dria, Stephen J; Eggers, Mitchell D
2016-10-01
The purpose of this study was to determine the in vitro clot capture efficiency (CCE) of an investigational absorbable inferior vena cava filter (IVCF) vs the Greenfield IVCF. Investigational absorbable and Greenfield filters were challenged with polyacrylamide clot surrogates ranging from 3 × 5 to 10 × 24 mm (diameter × length) in a flow loop simulating the venous system. Filters were challenged with clots until CCE standard error of 5% or less was achieved under binomial statistics. Pressure gradients across the filters were measured for the largest size clot, enabling calculation of forces on the filter. The in vitro CCE of the absorbable IVCF was statistically similar to that of the Greenfield filter for all clot sizes apart from the 3 × 10-mm clot, for which there was statistically significant difference between filter CCEs (absorbable filter, 59%; Greenfield filter, 31%; P = .0001). CCE ranged from an average 32% for the 3 × 5-mm clot to 100% for 7 × 10-mm and larger clots for the absorbable IVCF. Pressure gradient across the absorbable filter with 10 × 24-mm clot averaged 0.14 mm Hg, corresponding to a net force on the filter of 2.1 × 10(-3) N, compared with 0.39 mm Hg or 5.8 × 10(-3) N (P < .001) for the Greenfield filter. CCE of the absorbable filter was statistically similar to or an improvement on that of the Greenfield stainless steel filter for all clot sizes tested. CCE of the Greenfield filter in this study aligned with data from previous studies. Given the efficacy of the Greenfield filter in attenuating the risk of pulmonary embolism, the current study suggests that the absorbable filter may be a viable candidate for subsequent human testing. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
14-Day thawed plasma retains clot enhancing properties and inhibits tPA-induced fibrinolysis.
Huebner, Benjamin R; Moore, Ernest E; Moore, Hunter B; Shepherd-Singh, Raymond; Sauaia, Angela; Stettler, Gregory R; Nunns, Geoffrey R; Silliman, Christopher C
2017-11-01
Plasma-first resuscitation attenuates trauma-induced coagulopathy (TIC); however, the logistics of plasma-first resuscitation require thawed plasma (TP) be readily available due to the obligatory thawing time of fresh frozen plasma (FFP). The current standard is storage of TP for up to 5 days at 4°C, based on factor levels at outdate, for use in patients at risk for TIC, but there remains a 2.2% outdated wastage rate. However, the multitude of plasma proteins in attenuating TIC remains unknown. We hypothesize that TP retains the ability to enhance clotting and reduce tPA-induced fibrinolysis at 14-day storage. FFP was thawed and stored at 4°C at the following intervals: 14, 10, 7, 5, 3, and 1-day prior to the experiment. Healthy volunteers underwent blood draws followed by 50% dilution with TP stored at previously mentioned intervals as well as FFP, normal saline (NS), albumin, and whole blood (WB) control. Samples underwent tPA-modified (75 ng/mL) thrombelastography (TEG) with analysis of R-time, angle, maximum amplitude (MA), and LY30. TEG properties did not change significantly over the thawed storage. 14-day TP retained the ability to inhibit tPA-induced hyperfibrinolysis (median LY30% 9.6%) similar to FFP (5.6%), WB (14.6%), and superior to albumin (59.3%) and NS (58.1%). 14-day TP also retained faster clot formation (median angle, 66.2°) and superior clot strength (MA, 61.5 mm) to albumin (34.8°, 21.6 mm) and NS (41.6°, 32.2 mm). TP plasma stored for 14 days retains clot-enhancing ability and resistance to clot degradation similar to FFP. A clinical trial is needed to validate these in vitro results. Copyright © 2017 Elsevier Inc. All rights reserved.
Hoemann, C D; Sun, J; McKee, M D; Chevrier, A; Rossomacha, E; Rivard, G-E; Hurtig, M; Buschmann, M D
2007-01-01
We have previously shown that microfractured ovine defects are repaired with more hyaline cartilage when the defect is treated with in situ-solidified implants of chitosan-glycerol phosphate (chitosan-GP) mixed with autologous whole blood. The objectives of this study were (1) to characterize chitosan-GP/blood clots in vitro, and (2) to develop a rabbit marrow stimulation model in order to determine the effects of the chitosan-GP/blood implant and of debridement on the formation of incipient cartilage repair tissue. Blood clots were characterized by histology and in vitro clot retraction tests. Bilateral 3.5 x 4 mm trochlear defects debrided into the calcified layer were pierced with four microdrill holes and filled with a chitosan-GP/blood implant or allowed to bleed freely as a control. At 1 day post-surgery, initial defects were characterized by histomorphometry (n=3). After 8 weeks of repair, osteochondral repair tissues between or through the drill holes were evaluated by histology, histomorphometry, collagen type II expression, and stereology (n=16). Chitosan-GP solutions structurally stabilized the blood clots by inhibiting clot retraction. Treatment of drilled defects with chitosan-GP/blood clots led to the formation of a more integrated and hyaline repair tissue above a more porous and vascularized subchondral bone plate compared to drilling alone. Correlation analysis of repair tissue between the drill holes revealed that the absence of calcified cartilage and the presence of a porous subchondral bone plate were predictors of greater repair tissue integration with subchondral bone (P<0.005), and of a higher total O'Driscoll score (P<0.005 and P<0.01, respectively). Chitosan-GP/blood implants applied in conjunction with drilling, compared to drilling alone, elicited a more hyaline and integrated repair tissue associated with a porous subchondral bone replete with blood vessels. Concomitant regeneration of a vascularized bone plate during cartilage repair could provide progenitors, anabolic factors and nutrients that aid in the formation of hyaline cartilage.
Error analysis of numerical gravitational waveforms from coalescing binary black holes
NASA Astrophysics Data System (ADS)
Fong, Heather; Chu, Tony; Kumar, Prayush; Pfeiffer, Harald; Boyle, Michael; Hemberger, Daniel; Kidder, Lawrence; Scheel, Mark; Szilagyi, Bela; SXS Collaboration
2016-03-01
The Advanced Laser Interferometer Gravitational-wave Observatory (Advanced LIGO) has finished a successful first observation run and will commence its second run this summer. Detection of compact object binaries utilizes matched-filtering, which requires a vast collection of highly accurate gravitational waveforms. This talk will present a set of about 100 new aligned-spin binary black hole simulations. I will discuss their properties, including a detailed error analysis, which demonstrates that the numerical waveforms are sufficiently accurate for gravitational wave detection purposes, as well as for parameter estimation purposes.
[Histopathological changes in human placentas related to hypertensive disorders].
Artico, Luciano Guimarães; Madi, José Mauro; Godoy, Alessandra Eifler Guerra; Coelho, Celso Piccoli; Rombaldi, Renato Luís; Artico, Graziela Rech
2009-01-01
to determine the prevalence of histopathological changes, in human placentas, related to hypertensive syndromes. a transversal study that compares histopathological changes identified in 43 placentae from hypertensive pregnant women (HypPr), with the ones from 33 placentae from normotensive pregnant women (NorPr). The weight, volume and macroscopic and microscopic occurrence of infarctions, clots, hematomas, atherosis (partial obliteration, thickness of layers and presence of blood vessels hyalinization) and Tenney-Parker changes (absent, discreet and prominent), as well as the locating of infarctions and clots (central, peripheral or the association of both) have been analyzed. The chi2 and t Student tests have been used for the statistical analysis, as well as medians, standard deviations and ratios. It has been considered as significant, p<0.05. the macroscopic study of HypPr placentae have presented lower weight (461.1 versus 572.1 g) and volume (437.4 versus 542.0 cm(3)), higher infarction (51.2 versus 45.5%; p<0.05: OR=1.15) and clots (51.2 versus 15.1%; p<0.05; OR=5.4) ratios, as compared to the NorPr's. In the HypPr and NorPr, microscopic clots have occurred in 83.7 versus 45.5% (p<0.05; OR=4.3), respectively. Atherosis and Tenney-Parker changes have been statistically associated to the hypertensive syndromes (p<0.05). the obtained data allow us to associate lower placentary weight and volume, higher ratio of macro and microscopic infarction, clots, atherosis and Tenney-Parker changes to placentae of gestations occurring with hypertensive syndromes.
Dimeski, Goce; Masci, Paul P; Trabi, Manuela; Lavin, Martin F; de Jersey, John
2010-05-01
Obtaining a suitable specimen for analysis in a timely manner is pivotal in clinical chemistry service provision. Serum is recognized as the preferred specimen for most assays, but because of time constraints for completion of clotting and an increasing number of patients on anti-coagulant therapy, latent clotting or no clotting is an outcome which can lead to errors and delay in delivery of critical results. Although lithium heparin plasma has unique problems, it has become an alternative in hospital-based laboratories. The Becton-Dickinson (BD) rapid serum tube (RST) was evaluated in a hospital environment using a total of 53 participants, both healthy and anticoagulated, for 31 analytes against BD PST II and BD SST II tubes measured with Beckman DxC800 and DxI800 analyzers. Most results from the RST tube were comparable with those from the SST II tube. Potassium results were closer to the PST II plasma concentrations. Incomplete and latent clotting was encountered in the RST specimens from participants (cardiac and dialysis) who had received a total of >7000 units of heparin [activated partial thromboplastin time (APTT) >150 s], warfarin/heparin combination, and specimens from cardiac surgery patients who had received a total of >25,000 units of heparin (APTT >200 s) at the time of collection of specimens. The RST tube provides a suitable alternative to lithium heparin plasma tubes for most patients in a hospital environment. However, latent clotting continued to occur in specimens collected from participants who had received high concentrations of anticoagulants.
Atrial Fibrillation: Treatment
... options include medicines, medical procedures, and lifestyle changes. Blood Clot Prevention People who have AFib are at increased ... the heart's upper chambers (the atria), causing a blood clot to form. If the clot breaks off and ...
NASA Astrophysics Data System (ADS)
Wang, Feng; Yang, Dongkai; Zhang, Bo; Li, Weiqiang
2018-03-01
This paper explores two types of mathematical functions to fit single- and full-frequency waveform of spaceborne Global Navigation Satellite System-Reflectometry (GNSS-R), respectively. The metrics of the waveforms, such as the noise floor, peak magnitude, mid-point position of the leading edge, leading edge slope and trailing edge slope, can be derived from the parameters of the proposed models. Because the quality of the UK TDS-1 data is not at the level required by remote sensing mission, the waveforms buried in noise or from ice/land are removed by defining peak-to-mean ratio, cosine similarity of the waveform before wind speed are retrieved. The single-parameter retrieval models are developed by comparing the peak magnitude, leading edge slope and trailing edge slope derived from the parameters of the proposed models with in situ wind speed from the ASCAT scatterometer. To improve the retrieval accuracy, three types of multi-parameter observations based on the principle component analysis (PCA), minimum variance (MV) estimator and Back Propagation (BP) network are implemented. The results indicate that compared to the best results of the single-parameter observation, the approaches based on the principle component analysis and minimum variance could not significantly improve retrieval accuracy, however, the BP networks obtain improvement with the RMSE of 2.55 m/s and 2.53 m/s for single- and full-frequency waveform, respectively.
Erythrocyte migration and gap formation in rabbit blood clots in vitro.
Ueki, T; Yazama, F; Horiuchi, T; Yamada, M
2008-04-01
Thrombolytic agents must be carried by the blood circulation to thrombi to exert their functions. Structural gaps exist between blood vessels and thrombi or in the area surrounding thrombi. Therefore, information about fundamental gap formation at thrombotic areas is critically important for thrombolytic therapy. We previously reported that t-PA accelerates the activities of bovine erythrocytes and hemoglobin (Hb) towards bovine plasminogen activation. Here, we examined gap generation by observing morphological changes during thrombolytic processes in rabbit blood clots deformation of erythrocytes from blood clots and Hb transfer from erythrocytes to serum in vitro. Rabbit venous blood samples (1 ml) were stored under sterile conditions in glass tubes at 37 degrees C for 2, 24, 48 h, 1, and 2 weeks. We examined clot diameter, erythrocyte diameter and number as well as Hb volume in the serum, as well as histological changes in the clots. The diameter of blood clots did not change until 2 weeks after sampling. Erythrocyte diameter decreased within 48 h and at 2 weeks after sampling at the clot surface (p < 0.001) and interior (p < 0.001). The number of erythrocytes in the serum started to increase starting from 24 h after sampling (p < 0.01). Serum Hb volume also gradually increased from 24 h until 2 weeks after sampling (p < 0.01). The erythrocyte envelope became disrupted and cytoplasm started to flow through pores into the serum at 24 h. The results indicated that blood clots are reduced due to clot retraction, erythrocyte dissociation and cytoplasm leakage without a distinct fibrinolytic reaction. These results indicated that gaps start to form between 2 and 24 h after blood clotting.
Impact of Tissue Factor Localization on Blood Clot Structure and Resistance under Venous Shear.
Govindarajan, Vijay; Zhu, Shu; Li, Ruizhi; Lu, Yichen; Diamond, Scott L; Reifman, Jaques; Mitrophanov, Alexander Y
2018-02-27
The structure and growth of a blood clot depend on the localization of tissue factor (TF), which can trigger clotting during the hemostatic process or promote thrombosis when exposed to blood under pathological conditions. We sought to understand how the growth, structure, and mechanical properties of clots under flow are shaped by the simultaneously varying TF surface density and its exposure area. We used an eight-channel microfluidic device equipped with a 20- or 100-μm-long collagen surface patterned with lipidated TF of surface densities ∼0.1 and ∼2 molecules/μm 2 . Human whole blood was perfused at venous shear, and clot growth was continually measured. Using our recently developed computational model of clot formation, we performed simulations to gain insights into the clot's structure and its resistance to blood flow. An increase in TF exposure area resulted not only in accelerated bulk platelet, thrombin, and fibrin accumulation, but also in increased height of the platelet mass and increased clot resistance to flow. Moreover, increasing the TF surface density or exposure area enhanced platelet deposition by approximately twofold, and thrombin and fibrin generation by greater than threefold, thereby increasing both clot size and its viscous resistance. Finally, TF effects on blood flow occlusion were more pronounced for the longer thrombogenic surface than for the shorter one. Our results suggest that TF surface density and its exposure area can independently enhance both the clot's occlusivity and its resistance to blood flow. These findings provide, to our knowledge, new insights into how TF affects thrombus growth in time and space under flow. Copyright © 2018 Biophysical Society. All rights reserved.
NASA Astrophysics Data System (ADS)
Toma, Eiji
2018-06-01
In recent years, as the weight of IT equipment has been reduced, the demand for motor fans for cooling the interior of electronic equipment is on the rise. Sensory test technique by inspectors is the mainstream for quality inspection of motor fans in the field. This sensory test requires a lot of experience to accurately diagnose differences in subtle sounds (sound pressures) of the fans, and the judgment varies depending on the condition of the inspector and the environment. In order to solve these quality problems, development of an analysis method capable of quantitatively and automatically diagnosing the sound/vibration level of a fan is required. In this study, it was clarified that the analysis method applying the MT system based on the waveform information of noise and vibration is more effective than the conventional frequency analysis method for the discrimination diagnosis technology of normal and abnormal items. Furthermore, it was found that due to the automation of the vibration waveform analysis system, there was a factor influencing the discrimination accuracy in relation between the fan installation posture and the vibration waveform.
Izumi, Tatsuya; Hagiwara, Manabu; Hoshina, Takuya; Takeda, Hiroaki; Tsurumi, Takaaki
2012-08-01
We developed a possible method to determine both coefficients of piezoelectricity (d) and electrostriction (M) at the same time by a waveform analysis of current and vibration velocity in the resonance state. The waveforms of the current and vibration velocity were theoretically described using the equations of motion and piezoelectric constitutive equations, considering the dissipation effect. The dissipation factor of the d coefficient and M coefficient is dielectric loss tangent tan δ. The waveforms measured in all of the ceramics, such as Pb(Zr,Ti)O(3) (PZT), Pb(Mg,Nb)O(3) (PMN), and 0.8Pb(Mg(1/3)Nb2/3)O(3)-0.2PbTiO(3) (PMN-PT), were well fitted with the calculated waveform. This fitting produced both the d and M coefficients, which agreed with those determined via the conventional methods. Moreover, the respective contributions of both piezoelectricity and electrostriction to the d value determined in the resonance-antiresonance method were clarified.
Categorisation of full waveform data provided by laser scanning devices
NASA Astrophysics Data System (ADS)
Ullrich, Andreas; Pfennigbauer, Martin
2011-11-01
In 2004, a laser scanner device for commercial airborne laser scanning applications, the RIEGL LMS-Q560, was introduced to the market, making use of a radical alternative approach to the traditional analogue signal detection and processing schemes found in LIDAR instruments so far: digitizing the echo signals received by the instrument for every laser pulse and analysing these echo signals off-line in a so-called full waveform analysis in order to retrieve almost all information contained in the echo signal using transparent algorithms adaptable to specific applications. In the field of laser scanning the somewhat unspecific term "full waveform data" has since been established. We attempt a categorisation of the different types of the full waveform data found in the market. We discuss the challenges in echo digitization and waveform analysis from an instrument designer's point of view and we will address the benefits to be gained by using this technique, especially with respect to the so-called multi-target capability of pulsed time-of-flight LIDAR instruments.
... Dec Faces of Blood Clots Follow Us On Twitter Tweets by @StopTheClot Contact Info Phone: 703.935. ... 255 Vienna, VA 22182 more info Follow us Twitter Facebook Google Plus Email YouTube Pinterest Instagram DISCLAIMER ...
MedlinePlus Videos and Cool Tools
... the external bleeding stops. Clotting factors in the blood cause strands of blood-borne material, called fibrin, to stick together and ... the inside of the wound. Eventually, the cut blood vessel heals, and the blood clot dissolves after ...
Wang, Caroline W.; Perez, Matthew J.; Helmke, Brian P.; Viola, Francesco; Lawrence, Michael B.
2015-01-01
Despite the life-preserving function blood clotting serves in the body, inadequate or excessive blood clot stiffness has been associated with life-threatening diseases such as stroke, hemorrhage, and heart attack. The relationship between blood clot stiffness and vascular diseases underscores the importance of quantifying the magnitude and kinetics of blood’s transformation from a fluid to a viscoelastic solid. To measure blood plasma clot stiffness, we have developed a method that uses ultrasound acoustic radiation force (ARF) to induce micron-scaled displacements (1-500 μm) on microbeads suspended in blood plasma. The displacements were detected by optical microscopy and took place within a micro-liter sized clot region formed within a larger volume (2 mL sample) to minimize container surface effects. Modulation of the ultrasound generated acoustic radiation force allowed stiffness measurements to be made in blood plasma from before its gel point to the stage where it was a fully developed viscoelastic solid. A 0.5 wt % agarose hydrogel was 9.8-fold stiffer than the plasma (platelet-rich) clot at 1 h post-kaolin stimulus. The acoustic radiation force microbead method was sensitive to the presence of platelets and strength of coagulation stimulus. Platelet depletion reduced clot stiffness 6.9 fold relative to platelet rich plasma. The sensitivity of acoustic radiation force based stiffness assessment may allow for studying platelet regulation of both incipient and mature clot mechanical properties. PMID:26042775
EMBOLIC MIDDLE CEREBRAL ARTERY OCCLUSION MODEL USING THROMBIN AND FIBRINOGEN COMPOSED CLOTS IN RAT
Ren, Ming; Lin, Zi-Jing; Qian, Hai; Gourav, Choudhury Roy; liu, Ran; Liu, Hanli; Yang, Shao-Hua
2012-01-01
Ischemic stroke accounts for over 80% in total human stroke which mostly affect middle cerebral artery (MCA) territory. Embolic stroke models induced by injection of homologous clots into the internal carotid artery and MCA closely mimic human stroke and have been commonly used in stroke research. Studies indicate that the size and composition of clots are critical for the reproducibility of the stroke model. In the present study, we modified the homologous clots formation by addition of thrombin and fibrinogen which produced even distribution of fibrin with tight cross linkage of red blood cells. We optimized the embolic MCA occlusion model in rats using different size of the mixed clots. A precise lodgment of the clots at the MCA bifurcation and highly reproducible ischemic lesion in the MCA territory were demonstrated in the embolic MCA occlusion model induced by injection of 10 pieces of 1-mm long mixed clots made in PE-60 catheter. We further tested the effect of recombinant tissue plasminogen activator (rtPA) in this embolic MCA occlusion model. rtPA induced thrombolysis, improved neurological outcome, and significantly reduced ischemic lesion volume when administered at 1 hour after embolism as compared with control. In summary, we have established a reproducible embolic MCA occlusion model using clots made of homologous blood, thrombin and fibrinogen. The mixed clots enable precise lodgment at the MCA bifurcation which is responsive to thrombolytic therapy of rtPA. PMID:22985597
Embolic middle cerebral artery occlusion model using thrombin and fibrinogen composed clots in rat.
Ren, Ming; Lin, Zi-Jing; Qian, Hai; Choudhury, Gourav Roy; Liu, Ran; Liu, Hanli; Yang, Shao-Hua
2012-11-15
Ischemic stroke accounts for over 80% in total human stroke which mostly affect middle cerebral artery (MCA) territory. Embolic stroke models induced by injection of homologous clots into the internal carotid artery and MCA closely mimic human stroke and have been commonly used in stroke research. Studies indicate that the size and composition of clots are critical for the reproducibility of the stroke model. In the present study, we modified the homologous clots formation by addition of thrombin and fibrinogen which produced even distribution of fibrin with tight cross linkage of red blood cells. We optimized the embolic MCA occlusion model in rats using different size of the mixed clots. A precise lodgment of the clots at the MCA bifurcation and highly reproducible ischemic lesion in the MCA territory were demonstrated in the embolic MCA occlusion model induced by injection of 10 pieces of 1-mm long mixed clots made in PE-60 catheter. We further tested the effect of recombinant tissue plasminogen activator (rtPA) in this embolic MCA occlusion model. rtPA induced thrombolysis, improved neurological outcome, and significantly reduced ischemic lesion volume when administered at 1h after embolism as compared with control. In summary, we have established a reproducible embolic MCA occlusion model using clots made of homologous blood, thrombin and fibrinogen. The mixed clots enable precise lodgment at the MCA bifurcation which is responsive to thrombolytic therapy of rtPA. Copyright © 2012 Elsevier B.V. All rights reserved.
Case series: Bladder clot evacuation using a prostate morcellation device.
Doersch, Karen M; Navetta, Andrew F; Bird, Erin T; El Tayeb, Marawan M
2017-07-01
We sought to provide a technical update on the use of a prostate morcellator device (PMD) to manage organized blood clots of the bladder following laser prostatectomy. Herein, we describe our experience in using the Wolf Piranha morcellator in managing organized bladder blood clots supplemented with a retrospective chart review of the patients in whom this procedure was performed. Six patients, all male with a mean age of 75 ± 8.9 years, had organized bladder clots following either holmium laser enucleation or photoselective vaporization of the prostate managed with a PMD. Clots were recognized based on hematuria or urinary retention a median of 3.5 days following the aforementioned procedures. Initial management was attempted with more conservative measures, including a three-way Foley catheter, followed by cystoscopy with an Ellik evacuator, or a glass Tommey syringe. Morcellation times were a mean of 10.2 ± 6.15 minutes (range 2-18). This technique was able to manage clots that were an average of 173.3 ± 115.9 cc in size. The procedure was well-tolerated. No patients experienced intraoperative or morcellator-related complications. Benign prostatic hypertrophy frequently requires surgical endoscopic management and can be complicated by hematuria and bladder blood clot formation. When these clots become organized, this can lead to urinary retention and the required management, evacuation, may be difficult. The use of a Wolf Piranha PMD is a safe, well-tolerated, and effective in evacuating organized blood clots of the bladder.
da Silva, Ronivaldo Rodrigues; Souto, Tatiane Beltramini; de Oliveira, Tássio Brito; de Oliveira, Lilian Caroline Gonçalves; Karcher, Daniel; Juliano, Maria Aparecida; Juliano, Luiz; de Oliveira, Arthur H C; Rodrigues, André; Rosa, Jose C; Cabral, Hamilton
2016-08-01
In this study, we detail the specificity of an aspartic peptidase from Rhizomucor miehei and evaluate the effects of this peptidase on clotting milk using the peptide sequence of k-casein (Abz-LSFMAIQ-EDDnp) and milk powder. Molecular mass of the peptidase was estimated at 37 kDa, and optimum activity was achieved at pH 5.5 and 55 °C. The peptidase was stable at pH values ranging from 3 to 5 and temperatures of up 45 °C for 60 min. Dramatic reductions in proteolytic activity were observed with exposure to sodium dodecyl sulfate, and aluminum and copper (II) chloride. Peptidase was inhibited by pepstatin A, and mass spectrometry analysis identified four peptide fragments (TWSISYGDGSSASGILAK, ASNGGGGEYIFGGYDSTK, GSLTTVPIDNSR, and GWWGITVDRA), similar to rhizopuspepsin. The analysis of catalytic specificity showed that the coagulant activity of the peptidase was higher than the proteolytic activity and that there was a preference for aromatic, basic, and nonpolar amino acids, particularly methionine, with specific cleavage of the peptide bond between phenylalanine and methionine. Thus, this peptidase may function as an important alternative enzyme in milk clotting during the preparation of cheese.
Sersa, I; Vidmar, J; Grobelnik, B; Mikac, U; Tratar, G; Blinc, A
2007-06-07
Axially directed blood plasma flow can significantly accelerate thrombolysis of non-occlusive blood clots. Viscous forces caused by shearing of blood play an essential role in this process, in addition to biochemical fibrinolytic reactions. An analytical mathematical model based on the hypothesis that clot dissolution dynamics is proportional to the power of the flowing blood plasma dissipated along the clot is presented. The model assumes cylindrical non-occlusive blood clots with the flow channel in the centre, in which the flow is assumed to be laminar and flow rate constant at all times during dissolution. Effects of sudden constriction on the flow and its impact on the dissolution rate are also considered. The model was verified experimentally by dynamic magnetic resonance (MR) microscopy of artificial blood clots dissolving in an in vitro circulation system, containing plasma with a magnetic resonance imaging contrast agent and recombinant tissue-type plasminogen activator (rt-PA). Sequences of dynamically acquired 3D low resolution MR images of entire clots and 2D high resolution MR images of clots in the axial cross-section were used to evaluate the dissolution model by fitting it to the experimental data. The experimental data fitted well to the model and confirmed our hypothesis.
Activation of platelet-rich plasma using thrombin receptor agonist peptide.
Landesberg, Regina; Burke, Andrea; Pinsky, David; Katz, Ronald; Vo, Jennifer; Eisig, Sidney B; Lu, Helen H
2005-04-01
This study proposes an alternative preparation method of platelet-rich plasma (PRP). Specifically, we compare the use of thrombin receptor agonist peptide-6 (TRAP) and bovine thrombin as a clotting agent in the preparation of PRP. PRP was prepared by centrifugation and clotted with thrombin or TRAP. In vitro clotting times were monitored as a function of TRAP concentration, and clot retraction was determined by measuring clot diameter over time. Following the optimization of TRAP concentration, experiments were repeated with the addition of several commercially available bone substitutes. The release of PRP-relevant growth factors as a function of PRP preparation was also determined. The most rapid polymerization of PRP takes place with the addition of thrombin, followed by TRAP/Allogro (Ceramed, Lakewood, CO), TRAP/BioGlass (Mo-Sci, Rolla, MN), TRAP/BioOss (Osteohealth, Shirley, NY), and TRAP alone. Thrombin caused considerable clot retraction (43%), whereas TRAP alone resulted in only 15% retraction. TRAP/Allogro, TRAP/BioOss, and TRAP/BioGlass all exhibited minimal retraction (8%). The use of TRAP to activate clot formation in the preparation of PRP may be a safe alternative to bovine thrombin. It results in an excellent working time and significantly less clot retraction than the currently available methods of PRP production.
Waveform generation in the EETS
NASA Astrophysics Data System (ADS)
Wilshire, J. P.
1985-05-01
Design decisions and analysis for the waveform generation portion of an electrical equipment test set are discussed. This test set is unlike conventional ATE in that it is portable and designed to operate in forward area sites for the USMC. It is also unique in that it provides for functional testing for 32 electronic units from the AV-88 Harrier II aircraft. Specific requirements for the waveform generator are discussed, including a wide frequency range, high resolution and accuracy, and low total harmonic distortion. Several approaches to meet these requirements are considered and a specific concept is presented in detail, which consists of a digitally produced waveform that feeds a deglitched analog conversion circuit. Rigorous mathematical analysis is presented to prove that this concept meets the requirements. Finally, design alternatives and enhancements are considered.
Late clotted haemothorax after blunt chest trauma.
Sinha, P; Sarkar, P
1998-01-01
A clotted haemothorax can develop any time after blunt chest trauma. Two cases are described in which late clotted haemothoraces developed which were treated by limited thoracotomy and evacuation of clots. Late clotted haemothorax may occur even in the absence of any abnormal initial clinical findings. Early detection and treatment is important to avoid the complications of fibrothorax and empyema with permanent pulmonary dysfunction. After blunt chest trauma patients should be advised to return to the accident and emergency department for assessment on development of any new chest symptom. Under these circumstances a chest x ray is mandatory to exclude a haemothorax. Images Figure 1 PMID:9639184
Saliba, Christopher M; Clouthier, Allison L; Brandon, Scott C E; Rainbow, Michael J; Deluzio, Kevin J
2018-05-29
Abnormal loading of the knee joint contributes to the pathogenesis of knee osteoarthritis. Gait retraining is a non-invasive intervention that aims to reduce knee loads by providing audible, visual, or haptic feedback of gait parameters. The computational expense of joint contact force prediction has limited real-time feedback to surrogate measures of the contact force, such as the knee adduction moment. We developed a method to predict knee joint contact forces using motion analysis and a statistical regression model that can be implemented in near real-time. Gait waveform variables were deconstructed using principal component analysis and a linear regression was used to predict the principal component scores of the contact force waveforms. Knee joint contact force waveforms were reconstructed using the predicted scores. We tested our method using a heterogenous population of asymptomatic controls and subjects with knee osteoarthritis. The reconstructed contact force waveforms had mean (SD) RMS differences of 0.17 (0.05) bodyweight compared to the contact forces predicted by a musculoskeletal model. Our method successfully predicted subject-specific shape features of contact force waveforms and is a potentially powerful tool in biofeedback and clinical gait analysis.
Genetics Home Reference: protein S deficiency
... by the formation of blood clots within small blood vessels throughout the body. These blood clots disrupt normal blood flow and can lead to death of body tissue (necrosis). Widespread blood clotting uses up all available blood ...
Genetics Home Reference: hereditary antithrombin deficiency
... at higher than average risk for developing abnormal blood clots, particularly a type of clot that occurs in ... in the lungs. In hereditary antithrombin deficiency , abnormal blood clots usually form only in veins, although they may ...
Localization of Short-Chain Polyphosphate Enhances its Ability to Clot Flowing Blood Plasma
NASA Astrophysics Data System (ADS)
Yeon, Ju Hun; Mazinani, Nima; Schlappi, Travis S.; Chan, Karen Y. T.; Baylis, James R.; Smith, Stephanie A.; Donovan, Alexander J.; Kudela, Damien; Stucky, Galen D.; Liu, Ying; Morrissey, James H.; Kastrup, Christian J.
2017-02-01
Short-chain polyphosphate (polyP) is released from platelets upon platelet activation, but it is not clear if it contributes to thrombosis. PolyP has increased propensity to clot blood with increased polymer length and when localized onto particles, but it is unknown whether spatial localization of short-chain polyP can accelerate clotting of flowing blood. Here, numerical simulations predicted the effect of localization of polyP on clotting under flow, and this was tested in vitro using microfluidics. Synthetic polyP was more effective at triggering clotting of flowing blood plasma when localized on a surface than when solubilized in solution or when localized as nanoparticles, accelerating clotting at 10-200 fold lower concentrations, particularly at low to sub-physiological shear rates typical of where thrombosis occurs in large veins or valves. Thus, sub-micromolar concentrations of short-chain polyP can accelerate clotting of flowing blood plasma under flow at low to sub-physiological shear rates. However, a physiological mechanism for the localization of polyP to platelet or vascular surfaces remains unknown.
Fan, Natalie K.; Keegan, Philip M.; Platt, Manu O.; Averett, Rodney D.
2015-01-01
Fibrin is an extracellular matrix protein that is responsible for maintaining the structural integrity of blood clots. Much research has been done on fibrin in the past years to include the investigation of synthesis, structure-function, and lysis of clots. However, there is still much unknown about the morphological and structural features of clots that ensue from patients with disease. In this research study, experimental techniques are presented that allow for the examination of morphological differences of abnormal clot structures due to diseased states such as diabetes and sickle cell anemia. Our study focuses on the preparation and evaluation of fibrin clots in order to assess morphological differences using various experimental assays and confocal microscopy. In addition, a method is also described that allows for continuous, real-time calculation of lysis rates in fibrin clots. The techniques described herein are important for researchers and clinicians seeking to elucidate comorbid thrombotic pathologies such as myocardial infarctions, ischemic heart disease, and strokes in patients with diabetes or sickle cell disease. PMID:25867016
Acute toxicity of diphacinone in Northern bobwhite: Effects on survival and blood clotting
Rattner, Barnett A.; Horak, Katherine E.; Warner, Sarah E.; Johnston, John J.
2010-01-01
The anticoagulant rodenticide diphacinone was slightly toxic (acute oral LD50 2014 mg/kg) to Northern bobwhite (Colinus virginianus) in a 14-day acute toxicity trial. Precise and sensitive assays of blood clotting (prothrombin time, Russell?s Viper venom time, and thrombin clotting time) were adapted for use in quail, and this combination of assays is recommended to measure the effects of anticoagulant rodenticides. A single oral sublethal dose of diphacinone (434 mg/kg body weight) prolonged clotting time at 48 h post-dose compared to controls. At 783 mg/kg (approximate LD02), clotting time was prolonged at both 24 and 48 h post-dose. Prolongation of in vitro clotting time reflects impaired coagulation complex activity, and was detected before overt signs of toxicity were apparent at the greatest dosages (2868 and 3666 mg/kg) in the acute toxicity trial. These clotting time assays and toxicity data will assist in the development of a pharmacodynamic model to predict toxicity, and also facilitate rodenticide hazard and risk assessments in avian species.
Phase-space topography characterization of nonlinear ultrasound waveforms.
Dehghan-Niri, Ehsan; Al-Beer, Helem
2018-03-01
Fundamental understanding of ultrasound interaction with material discontinuities having closed interfaces has many engineering applications such as nondestructive evaluation of defects like kissing bonds and cracks in critical structural and mechanical components. In this paper, to analyze the acoustic field nonlinearities due to defects with closed interfaces, the use of a common technique in nonlinear physics, based on a phase-space topography construction of ultrasound waveform, is proposed. The central idea is to complement the "time" and "frequency" domain analyses with the "phase-space" domain analysis of nonlinear ultrasound waveforms. A nonlinear time series method known as pseudo phase-space topography construction is used to construct equivalent phase-space portrait of measured ultrasound waveforms. Several nonlinear models are considered to numerically simulate nonlinear ultrasound waveforms. The phase-space response of the simulated waveforms is shown to provide different topographic information, while the frequency domain shows similar spectral behavior. Thus, model classification can be substantially enhanced in the phase-space domain. Experimental results on high strength aluminum samples show that the phase-space transformation provides a unique detection and classification capabilities. The Poincaré map of the phase-space domain is also used to better understand the nonlinear behavior of ultrasound waveforms. It is shown that the analysis of ultrasound nonlinearities is more convenient and informative in the phase-space domain than in the frequency domain. Copyright © 2017 Elsevier B.V. All rights reserved.
Seismic waveform classification using deep learning
NASA Astrophysics Data System (ADS)
Kong, Q.; Allen, R. M.
2017-12-01
MyShake is a global smartphone seismic network that harnesses the power of crowdsourcing. It has an Artificial Neural Network (ANN) algorithm running on the phone to distinguish earthquake motion from human activities recorded by the accelerometer on board. Once the ANN detects earthquake-like motion, it sends a 5-min chunk of acceleration data back to the server for further analysis. The time-series data collected contains both earthquake data and human activity data that the ANN confused. In this presentation, we will show the Convolutional Neural Network (CNN) we built under the umbrella of supervised learning to find out the earthquake waveform. The waveforms of the recorded motion could treat easily as images, and by taking the advantage of the power of CNN processing the images, we achieved very high successful rate to select the earthquake waveforms out. Since there are many non-earthquake waveforms than the earthquake waveforms, we also built an anomaly detection algorithm using the CNN. Both these two methods can be easily extended to other waveform classification problems.
Blood Clots and Travel: What You Need to Know
... Icon View public health webinars on blood disorders Blood Clots and Travel: What You Need to Know Language: ... trip. Understand What Can Increase Your Risk for Blood Clots Even if you travel a long distance, the ...
Speech Analysis and Synthesis Based on Pitch-Synchronous Segmentation of the Speech Waveform.
1994-11-09
95.1 Nasality Distinguishes /n/ from /d/, /m/ from /b/, etc. 96.1 99.2 96.9 99.2 Sustention Distinguishes /ffrom /p/, 86.7 91.4 82.8 92.7/b/ from /v...first incoming pitch waveform becomes the first template, and it is stored in memory . Step 2: The amplitude spectrum of the next incoming pitch waveform
Martin, Sara M.; Holle, Lori A.; Cooley, Brian C.; Flick, Matthew J.
2018-01-01
The transglutaminase factor XIII (FXIII) stabilizes clots against mechanical and biochemical disruption and is essential for hemostasis. In vitro and in vivo models of venous thrombosis demonstrate that FXIII mediates clot size by promoting red blood cell (RBC) retention. However, the key source of FXIII and whether FXIII activity can be reduced to suppress thrombosis without imposing deleterious hemostatic consequences are 2 critical unresolved questions. FXIII is present in multiple compartments, including plasma (FXIIIplasma) as a heterotetramer of A2 and B2 subunits and platelets (FXIIIplt) as an A2 homodimer. We determined the role of the FXIII compartment and level in clot contraction, composition, and size in vitro and using in vivo models of hemostasis and venous thrombosis. Reducing overall FXIII levels decreased whole blood clot weight but did not alter thrombin generation or contraction of platelet-rich plasma clots. In reconstituted platelet-rich plasma and whole blood clot contraction assays, FXIIIplasma, but not FXIIIplt, produced high-molecular-weight fibrin crosslinks, promoted RBC retention, and increased clot weights. Genetically imposed reduction of FXIII delayed FXIII activation and fibrin crosslinking, suggesting FXIII levels mediate the kinetics of FXIII activation and activity and that the timing of these processes is a critical determinant of RBC retention during clot formation and contraction. A 50% reduction in FXIIIplasma produced significantly smaller venous thrombi but did not increase bleeding in tail transection or saphenous vein puncture models in vivo. Collectively, these findings suggest that partial FXIII reduction may be a therapeutic strategy for reducing venous thrombosis. PMID:29344582
Kattula, Sravya; Byrnes, James R; Martin, Sara M; Holle, Lori A; Cooley, Brian C; Flick, Matthew J; Wolberg, Alisa S
2018-01-09
The transglutaminase factor XIII (FXIII) stabilizes clots against mechanical and biochemical disruption and is essential for hemostasis. In vitro and in vivo models of venous thrombosis demonstrate that FXIII mediates clot size by promoting red blood cell (RBC) retention. However, the key source of FXIII and whether FXIII activity can be reduced to suppress thrombosis without imposing deleterious hemostatic consequences are 2 critical unresolved questions. FXIII is present in multiple compartments, including plasma (FXIII plasma ) as a heterotetramer of A 2 and B 2 subunits and platelets (FXIII plt ) as an A 2 homodimer. We determined the role of the FXIII compartment and level in clot contraction, composition, and size in vitro and using in vivo models of hemostasis and venous thrombosis. Reducing overall FXIII levels decreased whole blood clot weight but did not alter thrombin generation or contraction of platelet-rich plasma clots. In reconstituted platelet-rich plasma and whole blood clot contraction assays, FXIII plasma , but not FXIII plt , produced high-molecular-weight fibrin crosslinks, promoted RBC retention, and increased clot weights. Genetically imposed reduction of FXIII delayed FXIII activation and fibrin crosslinking, suggesting FXIII levels mediate the kinetics of FXIII activation and activity and that the timing of these processes is a critical determinant of RBC retention during clot formation and contraction. A 50% reduction in FXIII plasma produced significantly smaller venous thrombi but did not increase bleeding in tail transection or saphenous vein puncture models in vivo. Collectively, these findings suggest that partial FXIII reduction may be a therapeutic strategy for reducing venous thrombosis.
Eggers, Jürgen; Ossadnik, Stefan; Hütten, Heiko; Seidel, Günter
2009-12-01
Transcranial "diagnostic" ultrasound (US) has been shown to accelerate thrombolysis related to recombinant tissue-type plasminogen activator (rt-PA). In this in vitro study, we evaluated the potential of US to increase clot dissolution mediated by Abciximab (Abc) compared to rt-PA. The effect of 1.8-MHz pulsed wave (PW) Doppler US on dissolution of whole venous blood clots (WBC) and platelet-rich clots (PRC) treated with Abc and rt-PA was investigated in an in vitro model. Clot dissolution was measured by weight loss. Abc-related WBC dissolution was enhanced by additional US, but the effect was not any more detectable when the US was attenuated by a human temporal bone (US-tb). In PRC there was no additional effect of US on the Abc-related clot lysis. Rt-PA-related clot dissolution was increased by US in WBC and PRC as well, however, US-tb was only effective in WBC. The effect of insonation on WBC dissolution treated with the combination of Abc plus rt-PA was lower compared with those treated with rt-PA. In this in vitro experiment, the additional effect of "diagnostic" US in combination with Abc was only present in WBC and less strong than with rt-PA. The results do not support the use of Abc for sonothrombolysis targeting both, fibrin-rich and platelet-rich clots. In contrast, US when combined with rt-PA increases dissolution in both, WBC and PRC as well.
Three Variations in Rabbit Angiographic Stroke Models
Culp, William C.; Woods, Sean D.; Brown, Aliza T.; Lowery, John D.; Hennings, Leah J.; Skinner, Robert D.; Borrelli, Michael J.; Roberson, Paula K.
2012-01-01
Purpose To develop angiographic models of embolic stroke in the rabbit using pre-formed clot or microspheres to model clinical situations ranging from transient ischemic events to severe ischemic stroke. Materials and Methods New Zealand White rabbits (N=151) received angiographic access to the internal carotid artery (ICA) from a femoral approach. Variations of emboli type and quantity of emboli were tested by injection into the ICA. These included fresh clots (1.0-mm length, 3–6 h), larger aged clots (4.0-mm length, 3 days), and 2 or 3 insoluble microspheres (700–900 μm). Neurological assessment scores (NAS) were based on motor, sensory, balance, and reflex measures. Rabbits were euthanized at 4, 7, or 24 hours after embolization, and infarct volume was measured as a percent of total brain volume using 2,3,5-triphenyltetrazolium chloride (TTC). Results Infarct volume percent at 24 hours after stroke was lower for rabbits embolized with fresh clot (0.45% ± 0.14%), compared with aged clot (3.52% ± 1.31%) and insoluble microspheres (3.39% ± 1.04%). Overall NAS (including posterior vessel occlusions) were positively correlated to infarct volume percent measurements in the fresh clot (r=0.50), aged clot (r=0.65) and microsphere (r=0.62) models (p<0.001). Conclusion The three basic angiographic stroke models may be similar to human transient ischemic attacks (TIA) (fresh clot), major strokes that can be thrombolysed (aged clot), or major strokes with insoluble emboli such as atheromata (microspheres). Model selection can be tailored to specific research needs. PMID:23142182
Blood Clots That Kill: Preventing DVT | NIH MedlinePlus the Magazine
... please turn Javascript on. Feature: Deep Vein Thrombosis Blood Clots That Kill: Preventing DVT Past Issues / Spring 2011 ... Contents Deep vein thrombosis, or DVT, is a blood clot that forms in a vein deep in the ...
Intrapleural fibrinolysis in clotted haemothorax.
Agarwal, R; Aggarwal, A N; Gupta, D
2006-11-01
The immediate treatment of haemothorax is thoracostomy tube insertion. One complication of haemothorax is retained blood and if improperly managed, this can lead to complications such as empyema and fibrothorax. The ideal management of clotted haemothorax is a matter of controversy. Video-assisted thoracoscopic surgery (VATS) is believed to be the best available modality for the management of clotted haemothorax. However, VATS is not routinely available in many centres. One easily available and effective alternative to VATS is the use of intrapleural fibrinolysis. We report the successful management of a post-traumatic clotted haemaothorax in a 34-year-old man, using intrapleural instillation of streptokinase, and review the literature on the management of clotted haemothorax.
Platform for Postprocessing Waveform-Based NDE
NASA Technical Reports Server (NTRS)
Roth, Don
2008-01-01
Taking advantage of the similarities that exist among all waveform-based non-destructive evaluation (NDE) methods, a common software platform has been developed containing multiple- signal and image-processing techniques for waveforms and images. The NASA NDE Signal and Image Processing software has been developed using the latest versions of LabVIEW, and its associated Advanced Signal Processing and Vision Toolkits. The software is useable on a PC with Windows XP and Windows Vista. The software has been designed with a commercial grade interface in which two main windows, Waveform Window and Image Window, are displayed if the user chooses a waveform file to display. Within these two main windows, most actions are chosen through logically conceived run-time menus. The Waveform Window has plots for both the raw time-domain waves and their frequency- domain transformations (fast Fourier transform and power spectral density). The Image Window shows the C-scan image formed from information of the time-domain waveform (such as peak amplitude) or its frequency-domain transformation at each scan location. The user also has the ability to open an image, or series of images, or a simple set of X-Y paired data set in text format. Each of the Waveform and Image Windows contains menus from which to perform many user actions. An option exists to use raw waves obtained directly from scan, or waves after deconvolution if system wave response is provided. Two types of deconvolution, time-based subtraction or inverse-filter, can be performed to arrive at a deconvolved wave set. Additionally, the menu on the Waveform Window allows preprocessing of waveforms prior to image formation, scaling and display of waveforms, formation of different types of images (including non-standard types such as velocity), gating of portions of waves prior to image formation, and several other miscellaneous and specialized operations. The menu available on the Image Window allows many further image processing and analysis operations, some of which are found in commercially-available image-processing software programs (such as Adobe Photoshop), and some that are not (removing outliers, Bscan information, region-of-interest analysis, line profiles, and precision feature measurements).
Lane marking detection based on waveform analysis and CNN
NASA Astrophysics Data System (ADS)
Ye, Yang Yang; Chen, Hou Jin; Hao, Xiao Li
2017-06-01
Lane markings detection is a very important part of the ADAS to avoid traffic accidents. In order to obtain accurate lane markings, in this work, a novel and efficient algorithm is proposed, which analyses the waveform generated from the road image after inverse perspective mapping (IPM). The algorithm includes two main stages: the first stage uses an image preprocessing including a CNN to reduce the background and enhance the lane markings. The second stage obtains the waveform of the road image and analyzes the waveform to get lanes. The contribution of this work is that we introduce local and global features of the waveform to detect the lane markings. The results indicate the proposed method is robust in detecting and fitting the lane markings.
Analysis and Evaluation of Project EVERGREEN Data
1991-09-01
1 9 9c9" 9 9 9 91?t- VI vi rl i v AH AR AA R a- 6 4 h 1" t - 10 i h t -: .4 .a: : t : 3 t : ta at ~ ~’~ M ~4C ~ C0.~b ~ ~ qO ~ Cm @ el 0. z ~M C q f... Anton , Howard and Rorres , Chris, Elementary Linear Algebra with AyDlications, John Wiley and Sons, New York, 1987. 2. Binnall, Eugene P., EVERGREEN... C . ANALYSIS OF INDIVIDUAL WAVEFORMS.........52 1. Directory 5-1-90 . . . . . .. .. .. .. ... 58 a. Waveform NTSO4BO1.WFM............58 b. Waveform
Angular velocity of gravitational radiation from precessing binaries and the corotating frame
NASA Astrophysics Data System (ADS)
Boyle, Michael
2013-05-01
This paper defines an angular velocity for time-dependent functions on the sphere and applies it to gravitational waveforms from compact binaries. Because it is geometrically meaningful and has a clear physical motivation, the angular velocity is uniquely useful in helping to solve an important—and largely ignored—problem in models of compact binaries: the inverse problem of deducing the physical parameters of a system from the gravitational waves alone. It is also used to define the corotating frame of the waveform. When decomposed in this frame, the waveform has no rotational dynamics and is therefore as slowly evolving as possible. The resulting simplifications lead to straightforward methods for accurately comparing waveforms and constructing hybrids. As formulated in this paper, the methods can be applied robustly to both precessing and nonprecessing waveforms, providing a clear, comprehensive, and consistent framework for waveform analysis. Explicit implementations of all these methods are provided in accompanying computer code.
Tutwiler, Valerie; Litvinov, Rustem I; Lozhkin, Andrey P; Peshkova, Alina D; Lebedeva, Tatiana; Ataullakhanov, Fazoil I; Spiller, Kara L; Cines, Douglas B; Weisel, John W
2016-01-07
Platelet-driven blood clot contraction (retraction) is thought to promote wound closure and secure hemostasis while preventing vascular occlusion. Notwithstanding its importance, clot contraction remains a poorly understood process, partially because of the lack of methodology to quantify its dynamics and requirements. We used a novel automated optical analyzer to continuously track in vitro changes in the size of contracting clots in whole blood and in variously reconstituted samples. Kinetics of contraction was complemented with dynamic rheometry to characterize the viscoelasticity of contracting clots. This combined approach enabled investigation of the coordinated mechanistic impact of platelets, including nonmuscle myosin II, red blood cells (RBCs), fibrin(ogen), factor XIIIa (FXIIIa), and thrombin on the kinetics and mechanics of the contraction process. Clot contraction is composed of 3 sequential phases, each characterized by a distinct rate constant. Thrombin, Ca(2+), the integrin αIIbβ3, myosin IIa, FXIIIa cross-linking, and platelet count all promote 1 or more phases of the clot contraction process. In contrast, RBCs impair contraction and reduce elasticity, while increasing the overall contractile stress generated by the platelet-fibrin meshwork. A better understanding of the mechanisms by which blood cells, fibrin(ogen), and platelet-fibrin interactions modulate clot contraction may generate novel approaches to reveal and to manage thrombosis and hemostatic disorders. © 2016 by The American Society of Hematology.
Tutwiler, Valerie; Litvinov, Rustem I.; Lozhkin, Andrey P.; Peshkova, Alina D.; Lebedeva, Tatiana; Ataullakhanov, Fazoil I.; Spiller, Kara L.; Cines, Douglas B.
2016-01-01
Platelet-driven blood clot contraction (retraction) is thought to promote wound closure and secure hemostasis while preventing vascular occlusion. Notwithstanding its importance, clot contraction remains a poorly understood process, partially because of the lack of methodology to quantify its dynamics and requirements. We used a novel automated optical analyzer to continuously track in vitro changes in the size of contracting clots in whole blood and in variously reconstituted samples. Kinetics of contraction was complemented with dynamic rheometry to characterize the viscoelasticity of contracting clots. This combined approach enabled investigation of the coordinated mechanistic impact of platelets, including nonmuscle myosin II, red blood cells (RBCs), fibrin(ogen), factor XIIIa (FXIIIa), and thrombin on the kinetics and mechanics of the contraction process. Clot contraction is composed of 3 sequential phases, each characterized by a distinct rate constant. Thrombin, Ca2+, the integrin αIIbβ3, myosin IIa, FXIIIa cross-linking, and platelet count all promote 1 or more phases of the clot contraction process. In contrast, RBCs impair contraction and reduce elasticity, while increasing the overall contractile stress generated by the platelet-fibrin meshwork. A better understanding of the mechanisms by which blood cells, fibrin(ogen), and platelet-fibrin interactions modulate clot contraction may generate novel approaches to reveal and to manage thrombosis and hemostatic disorders. PMID:26603837
Deprés-Tremblay, Gabrielle; Chevrier, Anik; Tran-Khanh, Nicolas; Nelea, Monica; Buschmann, Michael D
2017-11-10
Platelet-rich plasma (PRP) has been used to treat different orthopedic conditions, however, the clinical benefits of using PRP remain uncertain. Chitosan (CS)-PRP implants have been shown to improve meniscus, rotator cuff and cartilage repair in pre-clinical models. The purpose of this current study was to investigate in vitro and in vivo mechanisms of action of CS-PRP implants. Freeze-dried formulations containing 1% (w/v) CS (80% degree of deacetylation and number average molar mass 38 kDa), 1% (w/v) trehalose as a lyoprotectant and 42.2 mM calcium chloride as a clot activator were solubilized in PRP. Gravimetric measurements and molecular/cellular imaging studies revealed that clot retraction is inhibited in CS-PRP hybrid clots through physical coating of platelets, blood cells and fibrin strands by chitosan, which interferes with platelet aggregation and platelet-mediated clot retraction. Flow cytometry and ELISA assays revealed that platelets are activated and granules secreted in CS-PRP hybrid clots and that cumulative release of platelet-derived growth factor (PDGF-AB) and epidermal growth factor is higher from CS-PRP hybrid clots compared to PRP clots in vitro. Finally, CS-PRP implants resided for up to 6 weeks in a subcutaneous implantation model and induced cell recruitment and granulation tissue synthesis, confirming greater residency and bioactivity compared to PRP in vivo.
USDA-ARS?s Scientific Manuscript database
Adaptive waveform interpretation with Gaussian filtering (AWIGF) and second order bounded mean oscillation operator Z square 2(u,t,r) are TDR analysis methods based on second order differentiation. AWIGF was originally designed for relatively long probe (greater than 150 mm) TDR waveforms, while Z s...
NASA Astrophysics Data System (ADS)
Park, Bumwoo; Furlan, Alessandro; Patil, Amol; Bae, Kyongtae T.
2010-03-01
Pulmonary embolism (PE) is a medical condition defined as the obstruction of pulmonary arteries by a blood clot, usually originating in the deep veins of the lower limbs. PE is a common but elusive illness that can cause significant disability and death if not promptly diagnosed and effectively treated. CT Pulmonary Angiography (CTPA) is the first line imaging study for the diagnosis of PE. While clinical prediction rules have been recently developed to associate short-term risks and stratify patients with acute PE, there is a dearth of objective biomarkers associated with the long-term prognosis of the disease. Clot (embolus) burden is a promising biomarker for the prognosis and recurrence of PE and can be quantified from CTPA images. However, to our knowledge, no study has reported a method for segmentation and measurement of clot from CTPA images. Thus, the purpose of this study was to develop a semi-automated method for segmentation and measurement of clot from CTPA images. Our method was based on Modified Seeded Region Growing (MSRG) algorithm which consisted of two steps: (1) the observer identifies a clot of interest on CTPA images and places a spherical seed over the clot; and (2) a region grows around the seed on the basis of a rolling-ball process that clusters the neighboring voxels whose CT attenuation values are within the range of the mean +/- two standard deviations of the initial seed voxels. The rollingball propagates iteratively until the clot is completely clustered and segmented. Our experimental results revealed that the performance of the MSRG was superior to that of the conventional SRG for segmenting clots, as evidenced by reduced degrees of over- or under-segmentation from adjacent anatomical structures. To assess the clinical value of clot burden for the prognosis of PE, we are currently applying the MSRG for the segmentation and volume measurement of clots from CTPA images that are acquired in a large cohort of patients with PE in an on-going NIH-sponsored clinical trial.
Compaction of fibrin clots reveals the antifibrinolytic effect of factor XIII.
Rijken, D C; Abdul, S; Malfliet, J J M C; Leebeek, F W G; Uitte de Willige, S
2016-07-01
Essentials Factor XIIIa inhibits fibrinolysis by forming fibrin-fibrin and fibrin-inhibitor cross-links. Conflicting studies about magnitude and mechanisms of inhibition have been reported. Factor XIIIa most strongly inhibits lysis of mechanically compacted or retracted plasma clots. Cross-links of α2-antiplasmin to fibrin prevent the inhibitor from being expelled from the clot. Background Although insights into the underlying mechanisms of the effect of factor XIII on fibrinolysis have improved considerably in the last few decades, in particular with the discovery that activated FXIII (FXIIIa) cross-links α2 -antiplasmin to fibrin, the topic remains a matter of debate. Objective To elucidate the mechanisms of the antifibrinolytic effect of FXIII. Methods and Results Platelet-poor plasma clot lysis, induced by the addition of tissue-type plasminogen activator, was measured in the presence or absence of a specific FXIIIa inhibitor. Both in a turbidity assay and in a fluorescence assay, the FXIIIa inhibitor had only a small inhibitory effect: 1.6-fold less tissue-type plasminogen activator was required for 50% clot lysis in the presence of the FXIIIa inhibitor. However, when the plasma clot was compacted by centrifugation, the FXIIIa inhibitor had a strong inhibitory effect, with 7.7-fold less tissue-type plasminogen activator being required for 50% clot lysis in the presence of the FXIIIa inhibitor. In both experiments, the effects of the FXIIIa inhibitor were entirely dependent on the cross-linking of α2 -antiplasmin to fibrin. The FXIIIa inhibitor reduced the amount of α2 -antiplasmin present in the compacted clots from approximately 30% to < 4%. The results were confirmed with experiments in which compaction was achieved by platelet-mediated clot retraction. Conclusions Compaction or retraction of fibrin clots reveals the strong antifibrinolytic effect of FXIII. This is explained by the cross-linking of α2 -antiplasmin to fibrin by FXIIIa, which prevents the plasmin inhibitor from being fully expelled from the clot during compaction/retraction. © 2016 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals, Inc. on behalf of International Society on Thrombosis and Haemostasis.
Mor-Cohen, Ronit; Rosenberg, Nurit; Averbukh, Yulia; Seligsohn, Uri; Lahav, Judith
2014-05-01
Integrin αIIbβ3 mediates platelet adhesion, aggregation and fibrin clot retraction. These processes require activation of αIIbβ3 and post-ligation signaling. Disulfide bond exchanges are involved in αIIbβ3 and αvβ3 activation. In order to investigate the role of integrin activation and disulfide bond exchange during αIIbβ3- and αvβ3-mediated clot retraction, we co-expressed in baby hamster kidney cells wild-type (WT) human αIIb and WT or mutated human β3 that contain single or double cysteine substitutions disrupting C523-C544 or C560-C583 bonds. Flow cytometry was used to measure surface expression and activation state of the integrins. Time-course of fibrin clot retraction was examined. Cells expressed WT or mutated human αIIbβ3 as well as chimeric hamster/human αvβ3. The αIIbβ3 mutants were constitutively active and the thiol blocker dithiobisnitrobenzoic acid (DTNB) did not affect their activation state. WT cells retracted the clot and addition of αvβ3 inhibitors decreased the retraction rate. The active mutants and WT cells activated by anti-LIBS6 antibody retracted the clot faster than untreated WT cells, particularly in the presence of αvβ3 inhibitor. DTNB substantially inhibited clot retraction by WT or double C523S/C544S mutant expressing cells, but minimally affected single C523S, C544S or C560S mutants. Anti-LIBS6-enhanced clot retraction was significantly inhibited by DTNB when added prior to anti-LIBS6. Both αIIbβ3 and αvβ3 contribute to clot retraction without prior activation of the integrins. Activation of αIIbβ3, but not of αvβ3 enhances clot retraction. Both αIIbβ3 activation and post-ligation signaling during clot retraction require disulfide bond exchange. Copyright © 2014 Elsevier Ltd. All rights reserved.
A novel platelet concentrate: titanium-prepared platelet-rich fibrin.
Tunalı, Mustafa; Özdemir, Hakan; Küçükodacı, Zafer; Akman, Serhan; Yaprak, Emre; Toker, Hülya; Fıratlı, Erhan
2014-01-01
We developed a new product called titanium-prepared platelet-rich fibrin (T-PRF). The T-PRF method is based on the hypothesis that titanium may be more effective in activating platelets than the silica activators used with glass tubes in Chouckroun's leukocyte- and platelet-rich fibrin (L-PRF) method. In this study, we aimed to define the structural characteristics of T-PRF and compare it with L-PRF. Blood samples were collected from 10 healthy male volunteers. The blood samples were drawn using a syringe. Nine milliliters was transferred to a dry glass tube, and 9 mL was transferred to a titanium tube. Half of each clot (i.e., the blood that was clotted using T-PRF or L-PRF) was processed with a scanning electron microscope (SEM). The other half of each clot was processed for fluorescence microscopy analysis and light microscopy analysis. The T-PRF samples seemed to have a highly organized network with continuous integrity compared to the other L-PRF samples. Histomorphometric analysis showed that T-PRF fibrin network covers larger area than L-PRF fibrin network; also fibrin seemed thicker in the T-PRF samples. This is the first human study to define T-PRF as an autogenous leukocyte- and platelet-rich fibrin product. The platelet activation by titanium seems to offer some high characteristics to T-PRF.
Solenoid valve performance characteristics studied
NASA Technical Reports Server (NTRS)
Abe, J. T.; Blackburn, S.
1970-01-01
Current and voltage waveforms of a solenoid coil are recorded as the valve opens and closes. Analysis of the waveforms with respect to time and the phase of the valve cycle accurately describes valve performance.
NASA Astrophysics Data System (ADS)
Shahzadi, Iqra; Nadeem, S.
2017-06-01
A genuine neurotic condition is experienced when some blood constituents accumulate on the wall of the artery get withdrew from the wall, again join the circulatory system and coagulation occur. Role of copper nanoparticles and inclined magnetic field on the peristaltic flow of a nanofluid in an annular region of inclined annulus is investigated. We represent the clot model by considering the small artery as an annulus whose outer tube has a wave of sinusoidal nature and inner tube has a clot on its walls. Lubrication approach is used to simplify the problem. Close form solutions are determined for temperature and velocity profile. Impact of related parameters on pressure rise, pressure gradient, velocity and streamlines are interpreted graphically. Comparison among the pure blood and copper blood is presented and analyzed. One main finding of the considered analysis is that the inclusion of copper nanoparticles enlarges the amplitude of the velocity. Therefore, the considered study plays a dominant role in biomedical applications.
Gravitational Radiation Characteristics of Nonspinning Black-Hole Binaries
NASA Technical Reports Server (NTRS)
Kelly, B. J.; Baker, J. G.; Boggs, W. D.; Centrella, J. M.; vanMeter, J. R.; McWilliams, S. T.
2008-01-01
We present a detailed descriptive analysis of the gravitational radiation from binary mergers of non-spinning black holes, based on numerical relativity simulations of systems varying from equal-mass to a 6:1 mass ratio. Our analysis covers amplitude and phase characteristics of the radiation, suggesting a unified picture of the waveforms' dominant features in terms of an implicit rotating source, applying uniformly to the full wavetrain, from inspiral through ringdown. We construct a model of the late-stage frequency evolution that fits the l = m modes, and identify late-time relationships between waveform frequency and amplitude. These relationships allow us to construct a predictive model for the late-time waveforms, an alternative to the common practice of modelling by a sum of quasinormal mode overtones. We demonstrate an application of this in a new effective-one-body-based analytic waveform model.
Enhancing high-order harmonic generation by sculpting waveforms with chirp
NASA Astrophysics Data System (ADS)
Peng, Dian; Frolov, M. V.; Pi, Liang-Wen; Starace, Anthony F.
2018-05-01
We present a theoretical analysis showing how chirp can be used to sculpt two-color driving laser field waveforms in order to enhance high-order harmonic generation (HHG) and/or extend HHG cutoff energies. Specifically, we consider driving laser field waveforms composed of two ultrashort pulses having different carrier frequencies in each of which a linear chirp is introduced. Two pairs of carrier frequencies of the component pulses are considered: (ω , 2 ω ) and (ω , 3 ω ). Our results show how changing the signs of the chirps in each of the two component pulses leads to drastic changes in the HHG spectra. Our theoretical analysis is based on numerical solutions of the time-dependent Schrödinger equation and on a semiclassical analytical approach that affords a clear physical interpretation of how our optimized waveforms lead to enhanced HHG spectra.
Blood Thinners: Can I Still Get Blood Clots?
... get blood clots? If you're taking a blood thinner, is it still possible to get a blood clot? Answers from Rekha Mankad, M.D. Yes. Medications that are commonly called blood thinners — such as aspirin, warfarin (Coumadin, Jantoven), dabigatran ( ...
Deep Vein Thrombosis (DVT) / Pulmonary Embolism (PE) - Blood Clot Forming in a Vein
... Controls Cancel Submit Search the CDC Venous Thromboembolism (Blood Clots) Note: Javascript is disabled or is not supported ... Challenge HA-VTE Data & Statistics HA-VTE Resources Blood Clots and Travel Research and Treatment Centers Data & Statistics ...
Analytic gravitational waveforms for generic precessing compact binaries
NASA Astrophysics Data System (ADS)
Chatziioannou, Katerina; Klein, Antoine; Cornish, Neil; Yunes, Nicolas
2017-01-01
Gravitational waves from compact binaries are subject to amplitude and phase modulations arising from interactions between the angular momenta of the system. Failure to account for such spin-precession effects in gravitational wave data analysis could hinder detection and completely ruin parameter estimation. In this talk I will describe the construction of closed-form, frequency-domain waveforms for fully-precessing, quasi-circular binary inspirals. The resulting waveforms can model spinning binaries of arbitrary spin magnitudes, spin orientations, and masses during the inspiral phase. I will also describe ongoing efforts to extend these inspiral waveforms to the merger and ringdown phases.
Hertle, R W; Maldanado, V K; Maybodi, M; Yang, D
2002-06-01
The infantile nystagmus syndrome (INS) usually begins in infancy and may or may not be associated with visual sensory system abnormalities. Little is known about its specific waveforms in the first 6 months of life or their relation to the developing visual system. This study identifies the clinical and ocular motility characteristics of the INS and establishes the range of waveforms present in the first 6 months of life. 27 infants with involuntary ocular oscillations typical of INS are included in this analysis. They were evaluated both clinically and with motility recordings. Eye movement analysis was performed off line from computer analysis of digitised data. Variables analysed included age, sex, vision, ocular abnormalities, head position, and null zone, neutral zone characteristics, symmetry, conjugacy, waveforms, frequencies, and foveation times. Ages ranged from 3 to 6.5 months (average 4.9 months). 15 patients (56%) had abnormal vision for age, nine (33%) had strabismus, five (19%) had an anomalous head posture, 13 (48%) had oculographic null and neutral positions, nine (33%) had binocular asymmetry, and only two showed consistent dysconjugacy. Average binocular frequency was 3.3 Hz, monocular frequency 6.6 Hz. Average foveation periods were longer and more "jerk" wave forms were observed in those patients with normal vision. Common clinical characteristics and eye movement waveforms of INS begin in the first few months of infancy and waveform analysis at this time may help with both diagnosis and visual status.
Atar, Shaul; Neuman, Yoram; Miyamoto, Takashi; Chen, Ming; Birnbaum, Yochai; Luo, Huai; Kobal, Sergio; Siegel, Robert J
2003-06-01
Aspirin, glycoprotein IIb/IIIa inhibitors and heparin are routinely used in acute coronary syndromes. Previously we showed that there is synergism between ultrasound and heparin and tirofiban in augmenting blood clot disruption. However, there is a little data on a possible synergism of low-frequency ultrasound with aspirin for in-vitro clot dissolution, and especially on the combination of aspirin with heparin and/or glycoprotein IIb/IIIa inhibitors. Human blood clots (n = 320) were incubated for 10 or 20 minutes in saline containing aspirin alone or combined with heparin and/or tirofiban and/or eptifibatide. Clots were randomly treated with low-frequency ultrasound (27.3 kHz) or incubation only. The percent clot weight loss and the incremental effect of ultrasound were calculated. The most significant incremental effect of ultrasound on clot weight reduction was detected with aspirin alone (5.2 +/- 2.3% and 5.2 +/- 2.6% after 10' and 20', p = 0.04 and p = 0.06, respectively) and in combination with heparin (8.8 +/- 2.5% and 11.5 +/- 2.7% after 10' and 20', p = 0.01 and p = 0.0001, respectively). The greatest absolute magnitude of clot weight reduction was observed with ultrasound combined with aspirin and heparin (48.5 +/- 9.5% after 20'). The addition of tirofiban or eptifibatide to aspirin, heparin and ultrasound did not increase clot lysis. However, eptifibatide had significantly better synergism than tirofiban (p = 0.025 and p = 0.015, after 10 and 20 minutes, respectively). Aspirin alone or in combination with heparin results in significant augmentation of clot lysis and is synergistic with application of low-frequency ultrasound for 10 and 20 minutes only. These results may have important implications for a possible use of low-frequency ultrasound in treatment algorithms of acute coronary syndromes.
Making the Right Choice: Optimizing rt-PA and eptifibatide lysis, an in vitro study
Shaw, George J.; Meunier, Jason M.; Lindsell, Christopher J.; Pancioli, Arthur M.; Holland, Christy K.
2010-01-01
Introduction Recombinant tissue plasminogen activator (rt-PA) is the only FDA approved lytic therapy for acute ischemic stroke. However, there can be complications such as intra-cerebral hemorrhage. This has led to interest in adjuncts such as GP IIb-IIIa inhibitors. However, there is little data on combined therapies. Here, we measure clot lysis for rt-PA and eptifibatide in an in vitro human clot model, and determine the drug concentrations maximizing lysis. A pharmacokinetic model is used to compare drug concentrations expected in clinical trials with those used here. The hypothesis is that there is a range of rt-PA and eptifibatide concentrations that maximize in vitro clot lysis. Materials and Methods Whole blood clots were made from blood obtained from 28 volunteers, after appropriate institutional approval. Sample clots were exposed to rt-PA and eptifibatide in human fresh-frozen plasma; rt-PA concentrations were 0, 0.5, 1, and 3.15 μg/ml, and eptifibatide concentrations were 0, 0.63, 1.05, 1.26 and 2.31 μg/ml. All exposures were for 30 minutes at 37 C. Clot width was measured using a microscopic imaging technique and mean fractional clot loss (FCL) at 30 minutes was used to determine lytic efficacy. On average, 28 clots (range: 6-148) from 6 subjects (3-24) were used in each group. Results and Conclusions FCL for control clots was 14% (95% Confidence Interval: 13-15%). FCL was 58% (55-61%) for clots exposed to both drugs at all concentrations, except those at an rt-PA concentration of 3.15 μg/ml, and eptifibatide concentrations of 1.26 μg/ml (Epf) or 2.31 μg/ml. Here, FCL was 43% (36-51) and 35% (32-38) respectively. FCL is maximized at moderate rt-PA and eptifibatide concentration; these values may approximate the average concentrations used in some rt-PA and eptifibatide treatments. PMID:20813398
A novel mechanism for hypofibrinolysis in diabetes: the role of complement C3.
Hess, K; Alzahrani, S H; Mathai, M; Schroeder, V; Carter, A M; Howell, G; Koko, T; Strachan, M W J; Price, J F; Smith, K A; Grant, P J; Ajjan, R A
2012-04-01
Impaired fibrin clot lysis is a key abnormality in diabetes and complement C3 is one protein identified in blood clots. This work investigates the mechanistic pathways linking C3 and hypofibrinolysis in diabetes using ex vivo/in vitro studies. Fibrinolysis and C3 plasma levels were determined in type 1 diabetic patients and healthy controls, and the effects of glycaemia investigated. C3 incorporation into fibrin clots and modulation of fibrinolysis were analysed by ELISA, immunoblotting, turbidimetric assays and electron and confocal microscopy. Clot lysis time was longer in diabetic children than in controls (599 ± 18 and 516 ± 12 s respectively; p < 0.01), C3 levels were higher in diabetic children (0.55 ± 0.02 and 0.43 ± 0.02 g/l respectively; p < 0.01) and both were affected by improving glycaemia. An interaction between C3 and fibrin was confirmed by the presence of lower protein levels in sera compared with corresponding plasma and C3 detection in plasma clots by immunoblot. In a purified system, C3 was associated with thinner fibrin fibres and more prolongation of lysis time of clots made from fibrinogen from diabetic participants compared with controls (244 ± 64 and 92 ± 23 s respectively; p < 0.05). Confocal microscopy showed higher C3 incorporation into diabetic clots compared with controls, and fully formed clot lysis was prolonged by 764 ± 76 and 428 ± 105 s respectively (p < 0.05). Differences in lysis, comparing diabetes and controls, were not related to altered plasmin generation or C3-fibrinogen binding assessed by plasmon resonance. C3 incorporation into clots from diabetic fibrinogen is enhanced and adversely affects fibrinolysis. This may be one novel mechanism for compromised clot lysis in diabetes, potentially offering a new therapeutic target.
In Vitro Assessment of Nanoparticle Effects on Blood Coagulation.
Potter, Timothy M; Rodriguez, Jamie C; Neun, Barry W; Ilinskaya, Anna N; Cedrone, Edward; Dobrovolskaia, Marina A
2018-01-01
Blood clotting is a complex process which involves both cellular and biochemical components. The key cellular players in the blood clotting process are thrombocytes or platelets. Other cells, including leukocytes and endothelial cells, contribute to clotting by expressing the so-called pro-coagulant activity (PCA) complex on their surface. The biochemical component of blood clotting is represented by the plasma coagulation cascade, which includes plasma proteins also known as coagulation factors. The coordinated interaction between platelets, leukocytes, endothelial cells, and plasma coagulation factors is necessary for maintaining hemostasis and for preventing excessive bleeding. Undesirable activation of all or some of these components may lead to pathological blood coagulation and life-threatening conditions such as consumptive coagulopathy or disseminated intravascular coagulation (DIC). In contrast, unintended inhibition of the coagulation pathways may lead to hemorrhage. Thrombogenicity is the property of a test material to induce blood coagulation by affecting one or more elements of the clotting process. Anticoagulant activity refers to the property of a test material to inhibit coagulation. The tendency to cause platelet aggregation, perturb plasma coagulation, and induce leukocyte PCA can serve as an in vitro measure of a nanomaterial's likelihood to be pro- or anticoagulant in vivo. This chapter describes three procedures for in vitro analyses of platelet aggregation, plasma coagulation time, and activation of leukocyte PCA. Platelet aggregation and plasma coagulation procedures have been described earlier. The revision here includes updated details about nanoparticle sample preparation, selection of nanoparticle concentration for the in vitro study, and updated details about assay controls. The chapter is expanded to describe a method for the leukocyte PCA analysis and case studies demonstrating the performance of these in vitro assays.
Banerjee, Anirban; Silliman, Christopher C; Moore, Ernest E; Dzieciatkowska, Monika; Kelher, Marguerite; Sauaia, Angela; Jones, Kenneth; Chapman, Michael P; Gonzalez, Eduardo; Moore, Hunter B; D'Alessandro, Angelo; Peltz, Erik; Huebner, Benjamin E; Einerson, Peter; Chandler, James; Ghasabayan, Arsen; Hansen, Kirk
2018-06-01
Viscoelastic measurements of hemostasis indicate that 20% of seriously injured patients exhibit systemic hyperfibrinolysis, with increased early mortality. These patients have normal clot formation with rapid clot lysis. Targeted proteomics was applied to quantify plasma proteins from hyperfibrinolytic (HF) patients to elucidate potential pathophysiology. Blood samples were collected in the field or at emergency department arrival and thrombelastography (TEG) was used to characterize in vitro clot formation under native and tissue plasminogen activator (tPA)-stimulated conditions. Ten samples were taken from injured patients exhibiting normal lysis time at 30 min (Ly30), "eufibrinolytic" (EF), 10 from HF patients, defined as tPA-stimulated TEG Ly30 >50%, and 10 from healthy controls. Trauma patient samples were analyzed by targeted proteomics and ELISA assays for specific coagulation proteins. HF patients exhibited increased plasminogen activation. Thirty-three proteins from the HF patients were significantly decreased compared with healthy controls and EF patients; 17 were coagulation proteins with anti-protease consumption (p < 0.005). The other 16 decreased proteins indicate activation of the alternate complement pathway, depletion of carrier proteins, and four glycoproteins. CXC7 was elevated in all injured patients versus healthy controls (p < 0.005), and 35 proteins were unchanged across all groups (p > 0.1 and fold change of concentrations of 0.75-1.3). HF patients had significant decreases in specific proteins and support mechanisms known in trauma-induced hyperfibrinolysis and also unexpected decreases in coagulation factors, factors II, X, and XIII, without changes in clot formation (SP, R times, or angle). Decreased clot stability in HF patients was corroborated with tPA-stimulated TEGs. Prognostic, level III.
Solomon, Cristina; Rahe-Meyer, Niels
2015-01-01
Background Administration of fibrinogen concentrate, targeting improved maximum clot firmness (MCF) of the thromboelastometric fibrin-based clot quality test (FIBTEM) is effective as first-line haemostatic therapy in aortic surgery. We performed a post-hoc analysis of data from a randomised, placebo-controlled trial of fibrinogen concentrate, to investigate whether fibrinogen concentrate reduced transfusion requirements for patients with platelet counts over or under 100×109/L. Material and methods Aortic surgery patients with coagulopathic bleeding after cardiopulmonary bypass were randomised to receive either fibrinogen concentrate (n=29) or placebo (n=32). Platelet count was measured upon removal of the aortic clamp, and coagulation and haematology parameters were measured peri-operatively. Transfusion of allogeneic blood components was recorded and compared between groups. Results After cardiopulmonary bypass, haemostatic and coagulation parameters worsened in all groups; plasma fibrinogen level (determined by the Clauss method) decreased by 43–58%, platelet count by 53–64%, FIBTEM maximum clot firmness (MCF) by 38–49%, FIBTEM maximum clot elasticity (MCE) by 43–54%, extrinsically activated test (EXTEM) MCF by 11–22%, EXTEM MCE by 25–41% and the platelet component of the clot by 23–39%. Treatment with fibrinogen concentrate (mean dose 7–9 g in the 4 groups) significantly reduced post-operative allogeneic blood component transfusion requirements when compared to placebo both for patients with a platelet count ≥100×109/L and for patients with a platelet count <100×109/L. Discussion FIBTEM-guided administration of fibrinogen concentrate reduced transfusion requirements when used as a first-line haemostatic therapy during aortic surgery in patients with platelet counts over or under 100×109/L. PMID:25369608
Sutton, Jonathan T; Ivancevich, Nikolas M; Perrin, Stephen R; Vela, Deborah C; Holland, Christy K
2013-05-01
We investigated ultrasound-enhanced thrombolysis in two whole-blood clot models using a Food and Drug Administration-approved contrast agent (Definity, Lantheus Medical Imaging; Billerica, MA USA) and thrombolytic drug (recombinant tissue-type plasminogen activator [rt-PA]) (Genentech; South San Francisco, CA USA). Porcine venous blood was collected from donor hogs and coagulated in vials made of two different materials. This method produced clots with differing compositional properties, as determined by routine scanning electron microscopy and histology. Clots were deployed in an ex vivo porcine thrombosis model, and exposed to an intermittent ultrasound scheme previously developed to maximize stable cavitation while acoustic emissions were detected. Exposure to 3.15 μg/mL rt-PA promoted lysis in both clot models, compared with exposure to plasma alone. However, only unretracted clots experienced significant enhancement of thrombolysis in the presence of rt-PA, Definity, and ultrasound, compared with treatment with rt-PA. In these clots, microscopy revealed loose erythrocyte aggregates, a significantly less extensive fibrin network and a higher porosity, which may facilitate increased penetration of thrombolytics by cavitation. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
A Fictitious Domain Method for Resolving the Interaction of Blood Flow with Clot Growth
NASA Astrophysics Data System (ADS)
Mukherjee, Debanjan; Shadden, Shawn
2016-11-01
Thrombosis and thrombo-embolism cause a range of diseases including heart attack and stroke. Closer understanding of clot and blood flow mechanics provides valuable insights on the etiology, diagnosis, and treatment of thrombotic diseases. Such mechanics are complicated, however, by the discrete and multi-scale phenomena underlying thrombosis, and the complex interactions of unsteady, pulsatile hemodynamics with a clot of arbitrary shape and microstructure. We have developed a computational technique, based on a fictitious domain based finite element method, to study these interactions. The method can resolve arbitrary clot geometries, and dynamically couple fluid flow with static or growing clot boundaries. Macroscopic thrombus-hemodynamics interactions were investigated within idealized vessel geometries representative of the common carotid artery, with realistic unsteady flow profiles as inputs. The method was also employed successfully to resolve micro-scale interactions using a model driven by in-vivo morphology data. The results provide insights into the flow structures and hemodynamic loading around an arbitrarily grown clot at arterial length-scales, as well as flow and transport within the interstices of platelet aggregates composing the clot. The work was supported by AHA Award No: 16POST27500023.
Geisler, David J; Fontaine, Nicolas K; Scott, Ryan P; He, Tingting; Paraschis, Loukas; Gerstel, Ori; Heritage, Jonathan P; Yoo, S J B
2011-04-25
We demonstrate an optical transmitter based on dynamic optical arbitrary waveform generation (OAWG) which is capable of creating high-bandwidth (THz) data waveforms in any modulation format using the parallel synthesis of multiple coherent spectral slices. As an initial demonstration, the transmitter uses only 5.5 GHz of electrical bandwidth and two 10-GHz-wide spectral slices to create 100-ns duration, 20-GHz optical waveforms in various modulation formats including differential phase-shift keying (DPSK), quaternary phase-shift keying (QPSK), and eight phase-shift keying (8PSK) with only changes in software. The experimentally generated waveforms showed clear eye openings and separated constellation points when measured using a real-time digital coherent receiver. Bit-error-rate (BER) performance analysis resulted in a BER < 9.8 × 10(-6) for DPSK and QPSK waveforms. Additionally, we experimentally demonstrate three-slice, 4-ns long waveforms that highlight the bandwidth scalable nature of the optical transmitter. The various generated waveforms show that the key transmitter properties (i.e., packet length, modulation format, data rate, and modulation filter shape) are software definable, and that the optical transmitter is capable of acting as a flexible bandwidth transmitter.
The Fibrin slide assay for detecting urokinase activity in human fetal kidney cells
NASA Technical Reports Server (NTRS)
Sedor, K.
1985-01-01
The Fibrin Slide Technique of Hau C. Kwaan and Tage Astrup is discussed. This relatively simple assay involves two steps: the formation of an artificial clot and then the addition of an enzyme (UKOKINASE) to dissolve the clot. The actual dissolving away of the clot is detected by the appearance of holes (lysis zones) in the stained clot. The procedure of Kwaan and Astrup is repeated, along with modifications and suggestions for improvements based on experience with the technique.
2009-09-01
OF A LINK-16/JTIDS COMPATIBLE WAVEFORM WITH NONCOHERENT DETECTION, DIVERSITY AND SIDE INFORMATION by Ioannis Kagioglidis September 2009... Noncoherent Detection, Diversity and Side Information. 6. AUTHOR Ioannis Kagioglidis 5. FUNDING NUMBERS 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES...baseband waveforms and detected noncoherently . For noncoherent detection, only one five bit symbol is transmitted on both the I and Q components of
Bhatti, M M; Zeeshan, A; Ellahi, R
2016-12-01
In this article, heat transfer analysis on clot blood model of the particle-fluid suspension through a non-uniform annulus has been investigated. The blood propagating along the whole length of the annulus was induced by peristaltic motion. The effects of variable viscosity and slip condition are also taken into account. The governing flow problem is modeled using lubrication approach by taking the assumption of long wavelength and creeping flow regime. The resulting equation for fluid phase and particle phase is solved analytically and closed form solutions are obtained. The physical impact of all the emerging parameters is discussed mathematically and graphically. Particularly, we considered the effects of particle volume fraction, slip parameter, the maximum height of clot, viscosity parameter, average volume flow rate, Prandtl number, Eckert number and fluid parameter on temperature profile, pressure rise and friction forces for outer and inner tube. Numerical computations have been used to determine the behavior of pressure rise and friction along the whole length of the annulus. The present study is also presented for an endoscope as a special case of our study. It is observed that greater influence of clot tends to rise the pressure rise significantly. It is also found that temperature profile increases due to the enhancement in Prandtl number, Eckert number, and fluid parameter. The present study reveals that friction forces for outer tube have higher magnitude as compared to the friction forces for an inner tube. In fact, the results for present study can also be reduced to the Newtonian fluid by taking ζ → ∞. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
A new method for concentration analysis of bacterial endotoxins in perfluorocarbon
NASA Astrophysics Data System (ADS)
Chen, Dan-Dan; Feng, Xiao-Ming; Wang, Chun-Ren; Huang, Qing-Quan; Yang, Zhao-Peng; Meng, Qing-Yuan
2014-12-01
This communication demonstrates the feasibility of the gel-clot method for the analysis of bacterial endotoxins in water extracts of perfluorocarbon which is a water insoluble liquid medical device. Perfluorocarbon (10 mL) was shaken with 10mL water for 15 min at 2000 r/min and the endotoxin present was extracted to the aqueous phase without interference inhibition/enhancement of the product and the recovery of endotoxin added to perfluorocarbon was determined. A validation study confirmed that endotoxins presented in perfluorocarbon pass over into the aqueous phase at concentrations of 20, 10 and 5 EU/mL with recoveries from 86.8% to 96.8%. Therefore, the gel-clot test is suitable for detecting bacterial endotoxins in perfluorocarbon which is a water insoluble medical device.
Pan, Xiaoxi; Gong, Yun Yun; Martinelli, Ida; Angelici, Laura; Favero, Chiara; Bertazzi, Pier Alberto; Mannucci, Pier M; Ariëns, Robert A S; Routledge, Michael N
2016-01-01
Particulate air pollution is a risk factor for cardiovascular diseases and thrombosis. Long-term exposure to particulate matter with a diameter<10μm (PM10) has been associated with an increased risk of venous thrombosis. The aim of this study was to investigate whether or not particulate air pollution alters fibrin clot structure and thus modulates thrombosis risk. We investigated fibrin polymerization by turbidity (maximum absorbance mOD), clot structure by confocal microscopy (fibre number per μm) and fibrin pore size by permeability (Ks×10(-10)cm(2)) in 103 patients with deep vein thrombosis and 121 healthy controls, for whom levels of air pollution exposure had been recorded. Exposure groups were defined by mean PM10 concentrations over the 730days before the event. We found a higher average number of fibres per clot area in patients than controls, but no difference in Ks or fibre thickness. When the two groups were divided into high or low exposure to PM10, a significantly denser fibrin clot network structure with thicker fibres (higher maximum absorbance, p<0.05), decreased permeability (lower Ks value, p<0.05) and higher average fibre numbers per clot area (p<0.05) was observed in patients in the high exposure group compared to those with low exposure. There were no significant differences in fibrin clot structure between the two exposure levels in healthy subjects. PM10 levels are associated with altered fibrin clot structure in patients with deep vein thrombosis but not in controls, suggesting that air pollution may trigger differences in fibrin clot structure only in patients predisposed to thrombotic disease. Copyright © 2016 Elsevier Ltd. All rights reserved.
Le Minh, Giang; Peshkova, Alina D; Andrianova, Izabella A; Sibgatullin, Timur B; Maksudova, Adelia N; Weisel, John W; Litvinov, Rustem I
2018-01-31
The aim of this work was to examine a possible role of clot contraction/retraction in thrombotic complications of systemic lupus erythematosus (SLE). Using a novel automated method, we investigated kinetics of clot contraction in the blood of 51 SLE patients and 60 healthy donors. The functionality of platelets in the SLE patients was assessed using flow cytometry by expression of P-selectin and fibrinogen-binding capacity. The rate and degree of clot contraction were significantly reduced in SLE patients compared with healthy subjects, especially in the patients with higher blood levels of anti-dsDNA antibodies. The reduced platelet contractility correlated with partial refractoriness of platelets isolated from the blood of SLE patients to stimulation induced by the thrombin receptor activating peptide. To test if the anti-dsDNA autoantibodies cause continuous platelet activation, followed by exhaustion and dysfunction of the cells, we added purified exogenous anti-dsDNA autoantibodies from SLE patients to normal blood before clotting. In support of this hypothesis, the antibodies first enhanced clot contraction and then suppressed it in a time-dependent manner. Importantly, a direct correlation of clot contraction parameters with the disease severity suggests that the reduced compactness of intravascular clots and thrombi could be a pathogenic factor in SLE that may exaggerate the impaired blood flow at the site of thrombosis. In conclusion, autoantibodies in SLE can affect platelet contractility, resulting in reduced ability of clots and thrombi to shrink in volume, which increases vessel obstruction and may aggravate the course and outcomes of thrombotic complications in SLE. © 2018 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.
Hess, Katharina; Ajjan, Ramzi; Phoenix, Fladia; Dobó, József; Gál, Péter; Schroeder, Verena
2012-01-01
Background Numerous interactions between the coagulation and complement systems have been shown. Recently, links between coagulation and mannan-binding lectin-associated serine protease-1 (MASP-1) of the complement lectin pathway have been proposed. Our aim was to investigate MASP-1 activation of factor XIII (FXIII), fibrinogen, prothrombin, and thrombin-activatable fibrinolysis inhibitor (TAFI) in plasma-based systems, and to analyse effects of MASP-1 on plasma clot formation, structure and lysis. Methodology/Principal Findings We used a FXIII incorporation assay and specific assays to measure the activation products prothrombin fragment F1+2, fibrinopeptide A (FPA), and activated TAFI (TAFIa). Clot formation and lysis were assessed by turbidimetric assay. Clot structure was studied by scanning electron microscopy. MASP-1 activated FXIII and, contrary to thrombin, induced FXIII activity faster in the Val34 than the Leu34 variant. MASP-1-dependent generation of F1+2, FPA and TAFIa showed a dose-dependent response in normal citrated plasma (NCP), albeit MASP-1 was much less efficient than FXa or thrombin. MASP-1 activation of prothrombin and TAFI cleavage were confirmed in purified systems. No FPA generation was observed in prothrombin-depleted plasma. MASP-1 induced clot formation in NCP, affected clot structure, and prolonged clot lysis. Conclusions/Significance We show that MASP-1 interacts with plasma clot formation on different levels and influences fibrin structure. Although MASP-1-induced fibrin formation is thrombin-dependent, MASP-1 directly activates prothrombin, FXIII and TAFI. We suggest that MASP-1, in concerted action with other complement and coagulation proteins, may play a role in fibrin clot formation. PMID:22536427
Artificial Intelligence Assists Ultrasonic Inspection
NASA Technical Reports Server (NTRS)
Schaefer, Lloyd A.; Willenberg, James D.
1992-01-01
Subtle indications of flaws extracted from ultrasonic waveforms. Ultrasonic-inspection system uses artificial intelligence to help in identification of hidden flaws in electron-beam-welded castings. System involves application of flaw-classification logic to analysis of ultrasonic waveforms.
Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate.
Shelley, Kirk H
2007-12-01
In this article, I examine the source of the photoplethysmograph (PPG), as well as methods of investigation, with an emphasize on amplitude, rhythm, and pulse analysis. The PPG waveform was first described in the 1930s. Although considered an interesting ancillary monitor, the "pulse waveform" never underwent intensive investigation. Its importance in clinical medicine was greatly increased with the introduction of the pulse oximeter into routine clinical care in the 1980s. Its waveform is now commonly displayed in the clinical setting. Active research efforts are beginning to demonstrate a utility beyond oxygen saturation and heart rate determination. Future trends are being heavily influenced by modern digital signal processing, which is allowing a re-examination of this ubiquitous waveform. Key to unlocking the potential of this waveform is an unfettered access to the raw signal, combined with standardization of its presentation, and methods of analysis. In the long run, we need to learn how to consistently quantify the characteristics of the PPG in such a way as to allow the results from research efforts be translated into clinically useful devices.
Arctic lead detection using a waveform mixture algorithm from CryoSat-2 data
NASA Astrophysics Data System (ADS)
Lee, Sanggyun; Kim, Hyun-cheol; Im, Jungho
2018-05-01
We propose a waveform mixture algorithm to detect leads from CryoSat-2 data, which is novel and different from the existing threshold-based lead detection methods. The waveform mixture algorithm adopts the concept of spectral mixture analysis, which is widely used in the field of hyperspectral image analysis. This lead detection method was evaluated with high-resolution (250 m) MODIS images and showed comparable and promising performance in detecting leads when compared to the previous methods. The robustness of the proposed approach also lies in the fact that it does not require the rescaling of parameters (i.e., stack standard deviation, stack skewness, stack kurtosis, pulse peakiness, and backscatter σ0), as it directly uses L1B waveform data, unlike the existing threshold-based methods. Monthly lead fraction maps were produced by the waveform mixture algorithm, which shows interannual variability of recent sea ice cover during 2011-2016, excluding the summer season (i.e., June to September). We also compared the lead fraction maps to other lead fraction maps generated from previously published data sets, resulting in similar spatiotemporal patterns.
Reduced clot debris size using standing waves formed via high intensity focused ultrasound
NASA Astrophysics Data System (ADS)
Guo, Shifang; Du, Xuan; Wang, Xin; Lu, Shukuan; Shi, Aiwei; Xu, Shanshan; Bouakaz, Ayache; Wan, Mingxi
2017-09-01
The feasibility of utilizing high intensity focused ultrasound (HIFU) to induce thrombolysis has been demonstrated previously. However, clinical concerns still remain related to the clot debris produced via fragmentation of the original clot potentially being too large and hence occluding downstream vessels, causing hazardous emboli. This study investigates the use of standing wave fields formed via HIFU to disintegrate the thrombus while achieving a reduced clot debris size in vitro. The results showed that the average diameter of the clot debris calculated by volume percentage was smaller in the standing wave mode than in the travelling wave mode at identical ultrasound thrombolysis settings. Furthermore, the inertial cavitation dose was shown to be lower in the standing wave mode, while the estimated cavitation bubble size distribution was similar in both modes. These results show that a reduction of the clot debris size with standing waves may be attributed to the particle trapping of the acoustic potential well which contributed to particle fragmentation.
Jones, Guy; Hunter, Finnie; Hancock, Hilary A; Kapoor, Ankur; Stone, Michael J; Wood, Bradford J; Xie, Jianwu; Dreher, Matthew R; Frenkel, Victor
2010-01-01
Investigations were carried out on the manner by which pulsed-high intensity focused ultrasound (HIFU) enhances the effectiveness of tissue plasminogen activator (tPA) in whole blood clots, in vitro. Scanning electronic microscope (SEM) of the surface of the clots showed that the exposures increased exposed fibrin, as well as the number of openings to more interior regions. These findings were supported by fluorescent antibody labeling of tPA in frozen sections of clots treated post-HIFU. Here, improved accumulation at the surface and penetration of the tPA into the clots were observed in those treated with HIFU. Fluorescence recovery after photobleaching was also performed, indicating that the diffusion coefficient increased 6.3-fold for fluorescently labeled dextrans, comparable in size to tPA, in the HIFU-treated clots. Improved understanding of the manner by which pulsed--HIFU exposures can improve the effectiveness of thrombolytics will help optimize the exposures for this application and potentially facilitate translation to the clinic.
Jones, Guy; Hunter, Finnie; Hancock, Hilary A.; Kapoor, Ankur; Stone, Michael J.; Wood, Bradford J.; Xie, Jianwu; Dreher, Matthew R.
2012-01-01
Investigations were carried out on the manner by which pulsed–high intensity focused ultrasound (HIFU) enhances the effectiveness of tissue plasminogen activator (tPA) in whole blood clots, in vitro. Scanning electronic microscope (SEM) of the surface of the clots showed that the exposures increased exposed fibrin, as well as the number of openings to more interior regions. These findings were supported by fluorescent antibody labeling of tPA in frozen sections of clots treated post-HIFU. Here, improved accumulation at the surface and penetration of the tPA into the clots were observed in those treated with HIFU. Fluorescence recovery after photobleaching was also performed, indicating that the diffusion coefficient increased 6.3-fold for fluorescently labeled dextrans, comparable in size to tPA, in the HIFU-treated clots. Improved understanding of the manner by which pulsed–HIFU exposures can improve the effectiveness of thrombolytics will help optimize the exposures for this application and potentially facilitate translation to the clinic. PMID:20064753
QuikClot masquerading as Glaser shot: a new forensic pathology artifact?
Moeng, Shirley Faith Angela Portia; Moar, Joshua J
2012-09-01
Although in the forensic sphere, Glaser ammunition or handgun shot cartridges represent one of the most significant advances in firearms ballistics in the past 100 years, the mineral-based zeolite hemostatic agent QuikClot represents a no less significant development in the surgical and clinical context of the trauma-induced management of battlefield wounding and hemorrhage. Because of the essential structural configuration of both Glaser ammunition and QuikClot, consisting as they do of metallic beads on the one hand and mineral-based spherules on the other, the possibility exists that a medicolegal autopsy on a victim of gunshot wounding and on whom surgery has been performed with introduction of QuikClot in an effort to stem bleeding, the spherules of QuikClot might be misinterpreted as the pellets of handgun shot cartridges.We present a case of fatal wounding by a 9-mm handgun in which the discovery of QuikClot in the peritoneal cavity at autopsy initially raised the possibility of wounding by Glaser ammunition.
Hérault, J-P; Cappelle, M; Bernat, A; Millet, L; Bono, F; Schaeffer, P; Herbert, J-M
2003-09-01
Factor (F)Xa and thrombin bound to the clot during its formation contribute to the propensity of thrombi to activate the coagulation system. The aim of this work was to study the inhibition of clot-bound FXa and clot-bound thrombin by SanOrg123781A, a synthetic hexadecasaccharide that enhances the inhibition of thrombin and FXa by antithrombin (AT). SanOrg123781A, designed to exhibit low non-specific binding to proteins other than AT, was compared with heparin. In buffer, heparin and SanOrg123781A inhibited FXa and thrombin at similar concentrations [concentration inhibiting 50% (IC50) of Xa and IIa activity were, respectively: heparin 120 +/- 7 and 3 +/- 1 ng mL-1; SanOrg123781A 77 +/- 5 and 4 +/- 1 ng mL-1]. In human plasma, the activity of both compounds was reduced, although the activity of heparin was much more affected than that of SanOrg123781A (IC50 values for inhibition of FXa and FIIa activity were, respectively: heparin 100 +/- 5 and 800 +/- 40 ng mL-1; SanOrg123781A 10 +/- 5 and 30 +/- 3 ng mL-1). We demonstrated, in agreement with our previous results, that the procoagulant activity of the clot is essentially due to clot-bound FXa and to some extent to clot-bound thrombin. We showed that heparin and SanOrg123781A were able to inhibit fragment F1+2 generation induced by clot-bound FXa with IC50 values of 2 +/- 0.5 micro g mL-1 and 0.6 +/- 0.2 micro g mL-1, respectively. Both compounds also inhibited clot-bound thrombin activity, the IC50 values of heparin and SanOrg123781A being 1 +/- 0.01 micro g mL-1 and 0.1 +/- 0.1 micro g mL-1, respectively. Moreover, both heparin and SanOrg123781A significantly inhibited fibrinopeptide A generated by the action of clot-bound thrombin on fibrinogen but also by free thrombin generated from prothrombin by clot-bound FXa with IC50 values of 4 +/- 0.6 and 1 +/- 0.1 micro g mL-1, respectively. As with clot-bound enzymatic activities, SanOrg123781A was three times more active than heparin in vivo on fibrinogen accretion onto a pre-existing thrombus and as activators of recombinant tissue-type plasminogen activator-induced thrombolysis. In conclusion, due to the specific activities of SanOrg123781A, this compound is much more active than heparin in the presence of plasma proteins, on clot-bound enzymes and in in vivo models of thrombosis/thrombolysis.
Lightning-channel morphology by return-stroke radiation field waveforms
NASA Technical Reports Server (NTRS)
Willett, J. C.; Le Vine, D. M.; Idone, V. P.
1995-01-01
Simultaneous video and wideband electric field recordings of 32 cloud-to-ground lightning flashes in Florida were analyzed to show the formation of new channels to ground can be detected by examination of the return-stroke radiation fields alone. The return-stroke E and dE/dt waveforms were subjectively classified according to their fine structure. Then the video images were examined field by field to identify each waveform with a visible channel to ground. Fifty-five correlated waveforms and channel images were obtained. Of these, all 34 first-stroke waveforms (multiple jagged E peaks, noisy dE/dt), 8 of which were not radiated by the chronologically first stroke in the flash, came from new channels to ground (not previously seen on video). All 18 subsequent-stroke waveforms (smoothly rounded E and quiet dE/dt after initial peak) were radiated by old channels (illuminated by a previous stroke). Two double-ground waveforms (two distinct first-return-stroke pulses separated by tens of microseconds or less) coincided with video fields showing two new channels. One `anomalous-stroke' waveform (beginning like a first stroke and ending like a subsequent) was produced by a new channel segment to ground branching off an old channel. This waveform classification depends on the presence or absence of high-frequency fine structure. Fourier analysis shows that first-stroke waveforms contain about 18 dB more spectral power in the frequency interval from 500 kHz to at least 7 MHz than subsequent-stroke waveforms for at least 13 microseconds after the main peak.
Antibacterial effects of fibrin glue-antibiotic mixtures.
Kram, H B; Bansal, M; Timberlake, O; Shoemaker, W C
1991-02-01
In the present in vitro study, we investigated the duration of action and antibacterial effects of nonautologous fibrin glue (FG) combined with antibiotics (Abs) including Ciprofloxacin, Teicoplanin, Cefoxitin, and Gentamicin; the effect of FG alone on bacterial growth was also evaluated. The rate of Ab diffusion from combined FG-Ab clots was evaluated by separate elution with pooled human serum (HS) and normal saline (NS); supernatants were removed daily and assayed for active concentrations of each Ab. The effects of FG and combined FG-Ab clots on bacterial growth were evaluated by inoculating brain-heart infusion (BHI) with Staphylococcus aureus, followed by the addition of FG or FG-Ab clots; a separate set of studies was also performed with the addition of mouse lung homogenate (MLH) as well. The addition of Ab to FG clots resulted in continuous diffusion of the Ab into the surrounding HS or NS for up to 5 to 7 days; however, more than two-thirds of the Ab diffused out within 2 to 3 days regardless of the Ab used. The antibacterial effects of FG-Ciprofloxacin and FG-Teicoplanin clots were significant compared to those of FG clots not containing Ab. In addition, the presence of FG clots (in BHI) resulted in a reduction in bacterial growth compared to that of BHI alone. The addition of MLH to BHI resulted in increased bacterial growth, but this effect was inhibited by the presence of combined FG-Ab clots.(ABSTRACT TRUNCATED AT 250 WORDS)
Ye, Aiqian; Cui, Jian; Dalgleish, Douglas; Singh, Harjinder
2017-01-01
The effects of homogenization and heat treatment on the formation and the breakdown of clots during gastric digestion of whole milk were investigated using a human gastric simulator. Homogenization and heat treatment led to formation of coagula with fragmented and crumbled structures compared with the coagulum formed from raw whole milk, but a larger fraction of the protein and more fat globules were incorporated into the coagula induced by action of the milk-clotting enzyme pepsin. The fat globules in the whole milk appeared to be embedded in the clots as they formed. After formation of the clot, the greater numbers of pores in the structures of the clots formed with homogenized milk and heated whole milk led to greater rates of protein hydrolysis by pepsin, which resulted in faster release of fat globules from the clots into the digesta. Coalescence of fat globules occurred both in the digesta and within the protein clots no matter whether they were in homogenized or heated milk samples. The formation of clots with different structures and hence the changes in the rates of protein hydrolysis and the release of milk fat into the digesta in the stomach provide important information for understanding the gastric emptying of milk and the potential to use this knowledge to manipulate the bioavailability of fat and other fat-soluble nutrients in dairy products. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Li, Yang; Pan, Chuer; Li, Yunfeng; Kumacheva, Eugenia; Ramachandran, Arun
2017-09-08
Embolic ischemia and pulmonary embolism are health emergencies that arise when a particle such as a blood clot occludes a smaller blood vessel in the brain or the lungs, and restricts flow of blood downstream of the vessel. In this work, the reflow technique (Wang et al. Biomed. Microdevices 2007, 9, 657) was adapted to produce a microchannel network that mimics the occlusion process. The technique was first revisited and a simple geometrical model was developed to quantitatively explain the shapes of the resulting microchannels for different reflow parameters. A critical modification was introduced to the reflow protocol to fabricate nearly circular microchannels of different diameters from the same master, which is not possible with the traditional reflow technique. To simulate the phenomenon of occlusion by clots, a microchannel network with three generations of branches with different diameters and branching angles was fabricated, into which fibrin clots were introduced. At low constant pressure drop (ΔP), a clot blocked a branch entrance only partially, while at higher ΔP, the branch was completely blocked. Instances of simultaneous blocking of multiple channels by clots, and the consequent changes in the flow rates in the unblocked branches of the network, were also monitored. This work provides the framework for a systematic study of the distribution of clots in a network, and the rate of dissolution of embolic clots upon the introduction of a thrombolytic drug into the network.
In vivo flow cytometry of circulating clots using negative photothermal and photoacoustic contrasts.
Galanzha, Ekaterina I; Sarimollaoglu, Mustafa; Nedosekin, Dmitry A; Keyrouz, Salah G; Mehta, Jawahar L; Zharov, Vladimir P
2011-10-01
Conventional photothermal (PT) and photoacousic (PA) imaging, spectroscopy, and cytometry are preferentially based on positive PT/PA effects, when signals are above background. Here, we introduce PT/PA technique based on detection of negative signals below background. Among various new applications, we propose label-free in vivo flow cytometry of circulating clots. No method has been developed for the early detection of clots of different compositions as a source of thromboembolism including ischemia at strokes and myocardial infarction. When a low-absorbing, platelet-rich clot passes a laser-irradiated vessel volume, a transient decrease in local absorption results in an ultrasharp negative PA hole in blood background. Using this phenomenon alone or in combination with positive contrasts, we demonstrated identification of white, red, and mixed clots on a mouse model of myocardial infarction and human blood. The concentration and size of clots were measured with threshold down to few clots in the entire circulation with size as low as 20 μm. This multiparameter diagnostic platform using portable personal high-speed flow cytometer with negative dynamic contrast mode has potential to real-time defining risk factors for cardiovascular diseases, and for prognosis and prevention of stroke or use clot count as a marker of therapy efficacy. Possibility for label-free detection of platelets, leukocytes, tumor cells or targeting themby negative PA probes (e.g., nonabsorbing beads or bubbles) is also highlighted. Copyright © 2011 International Society for Advancement of Cytometry.
Blood clot detection using magnetic nanoparticles
NASA Astrophysics Data System (ADS)
Khurshid, Hafsa; Friedman, Bruce; Berwin, Brent; Shi, Yipeng; Ness, Dylan B.; Weaver, John B.
2017-05-01
Deep vein thrombosis, the development of blood clots in the peripheral veins, is a very serious, life threatening condition that is prevalent in the elderly. To deliver proper treatment that enhances the survival rate, it is very important to detect thrombi early and at the point of care. We explored the ability of magnetic particle spectroscopy (MSB) to detect thrombus via specific binding of aptamer functionalized magnetic nanoparticles with the blood clot. MSB uses the harmonics produced by nanoparticles in an alternating magnetic field to measure the rotational freedom and, therefore, the bound state of the nanoparticles. The nanoparticles' relaxation time for Brownian rotation increases when bound [A.M. Rauwerdink and J. B. Weaver, Appl. Phys. Lett. 96, 1 (2010)]. The relaxation time can therefore be used to characterize the nanoparticle binding to thrombin in the blood clot. For longer relaxation times, the approach to saturation is more gradual reducing the higher harmonics and the harmonic ratio. The harmonic ratios of nanoparticles conjugated with anti-thrombin aptamers (ATP) decrease significantly over time with blood clot present in the sample medium, compared with nanoparticles without ATP. Moreover, the blood clot removed from the sample medium produced a significant MSB signal, indicating the nanoparticles are immobilized on the clot. Our results show that MSB could be a very useful non-invasive, quick tool to detect blood clots at the point of care so proper treatment can be used to reduce the risks inherent in deep vein thrombosis.
Galanzha, Ekaterina I.; Sarimollaoglu, Mustafa; Nedosekin, Dmitry A.; Keyrouz, Salah G.; Mehta, Jawahar L.; Zharov, Vladimir P.
2012-01-01
Conventional photothermal (PT) and photoacousic (PA) imaging, spectroscopy, and cytometry are preferentially based on positive PT/PA effects, when signals are above background. Here, we introduce PT/PA technique based on detection of negative signals below background. Among various new applications, we propose label-free in vivo flow cytometry of circulating clots. No method has been developed for the early detection of clots of different compositions as a source of severe thromboembolisms including ischemia at strokes and myocardial dysfunction at heart attack. When a low-absorbing, platelet-rich clot passes a laser-irradiated vessel volume, a transient decrease in local absorption results in an ultrasharp negative PA hole in blood background. Using this phenomenon alone or in combination with positive contrasts, we demonstrated identification of white, red and mixed clots on a mouse model of myocardial infarction and human blood. The concentration and size of clots were measured with threshold down to few clots in the entire circulation with size as low as 20 µm. This multiparameter diagnostic platform using portable personal high-speed flow cytometer with negative dynamic contrast mode has potential to real-time defining risk factors for cardiovascular diseases, and for prognosis and prevention of stroke or use clot count as a marker of therapy efficacy. Possibility for label-free detection of platelets, leukocytes, tumor cells or targeting them by negative PA probes (e.g., nonabsorbing beads or bubbles) is also highlighted. PMID:21976458
Rediscovering the wound haematoma as a site of haemostasis during major arterial haemorrhage
White, N.J.; Mehic, E.; Wang, X.; Chien, D.; Lim, E.; St. John, A.E.; Stern, S.A.; Mourad, P.D.; Rieger, M.; Fries, D.; Martinowitz, U.
2015-01-01
Background Treatments for major internal bleeding after injury include permissive hypotension to decrease the rate of blood loss, intravenous infusion of plasma or clotting factors to improve clot formation, and rapid surgical haemostasis or arterial embolization to control bleeding vessels. Yet, little is known regarding major internal arterial haemostasis, or how these commonly-used treatments might influence haemostasis. Objectives (1) Use a swine model of femoral artery bleeding to understand the perivascular haemostatic response to contained arterial haemorrhage. (2) Directly confirm the association between hemodynamics and bleeding velocity. (3) Observe the feasibility of delivering an activated clotting factor directly to internal sites of bleeding using a simplified angiographic approach. Methods Ultrasound was used to measure bleeding velocity and in vivo clot formation by elastography in a swine model of contained femoral artery bleeding with fluid resuscitation. A swine model of internal pelvic and axillary artery haemorrhage was also used to demonstrate feasibility of local delivery of an activated clotting factor. Results In this model, clots formed slowly within the peri-wound hematoma , but eventually containing the bleeding. Central hemodynamics correlated positively with bleeding velocity. Infusion of recombinant human activated Factor VII into the injured artery nearby the site of major internal haemorrhage in the pelvis and axillae was feasible. Conclusions We rediscover that clot formation within the peri-wound haematoma is an integral component of haemostasis and a feasible target for treatment of major internal bleeding using activated clotting factors delivered using a simplified angiographic approach. PMID:26414624
Kam, Pca; Liou, Jpc; Yang, Kxf
2017-09-01
We evaluated the effects of haemodilution with either dextran 40 or 0.9% normal saline on coagulation in vitro using rotational thromboelastometry (ROTEM®, Pentapharm Co., Munich, Germany) and multiple electrode aggregometry (Multiplate® Platelet Function Analyser, Dynabyte, Munich, Germany). Venous blood samples obtained from 20 healthy volunteers were diluted in vitro with dextran 40 or normal saline by 5%, 10% and 15%. Fibrinogen concentration, ROTEM-EXTEM® (screening test for the extrinsic coagulation pathway), FIBTEM® (an EXTEM-based assay of the fibrin component of clot) parameters including coagulation time, clot formation time, alpha angle, maximum clot firmness and lysis index were measured in the undiluted sample and at each level of haemodilution. Dextran 40 at 15% haemodilution significantly prolonged coagulation time, clot formation time and significantly decreased the alpha angle and maximal clot firmness (EXTEM amplitude at five minutes [A5] and ten minutes [A10]) compared with normal saline. The FIBTEM assay (maximal clot firmness and FIBTEM A5 and A10) showed a marked decrease in maximal clot firmness at all dilutions suggesting impaired fibrinogen activity and a risk of bleeding. Multiple electrode aggregometry did not demonstrate any platelet dysfunction. Haemodilution with dextran 40 causes significant impairment in clot formation and strength compared to saline haemodilution and undiluted blood. At the levels of in vitro haemodilution designed to reflect the clinical use of dextran infusions, no significant fibrinolysis or platelet inhibition was observed.
Characterization and milk coagulating properties of Cynanchum otophyllum Schneid. proteases.
Luo, Jie; Xiao, Chen; Zhang, Hao; Ren, Fazheng; Lei, Xingen; Yang, Zibiao; Yu, Zhengquan
2018-04-01
The herbaceous plant Cynanchum otophyllum Schneid. is widely used as a milk coagulant to make a Chinese traditional milk product, milk cake. However, the milk-clotting compounds and their mechanism remain unclear. In this study, crude proteases were extracted from the dried leaves of Cynanchum otophyllum Schneid. using citric acid-phosphate buffer and then partially purified by weak anion exchange chromatography. Two proteases, QA and QC, with molecular weights of 14 and 27 kDa, respectively, were shown to exhibit milk-clotting activity. A study of the effects of pH and temperature on the milk-clotting activity and proteolytic activity of the proteases showed that they exhibited good pH stability from pH 5.5 to 7.5 and good thermal stability at temperatures from 50 to 70°C. The QA and QC were the cysteine proteases, able to hydrolyze β-casein and κ-casein completely, and α-casein partially. The cleavage site on κ-casein determined by Orbitrap (Thermo Fisher Scientific, San Jose, CA) analysis showed that QA and QC could cleave κ-casein at Ser132-Thr133. Overall, the results suggest that the Cynanchum otophyllum Schneid. proteases are a promising milk-clotting enzyme that could be used for manufacturing milk cake and cheese. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
How to Spot and Prevent Deep Vein Thrombosis
... leg. But if your symptoms stem from a blood clot deep in your leg, it can be dangerous. Blood clots can happen to anyone, anytime. But some people ... Taking steps to reduce your chances of a blood clot forming in your veins can help you avoid ...
Thermal Blood Clot Formation and use in Microfluidic Device Valving Applications
NASA Technical Reports Server (NTRS)
Tai, Yu-Chong (Inventor); Shi, Wendian (Inventor); Guo, Luke (Inventor)
2014-01-01
The present invention provides a method of forming a blood-clot microvalve by heating blood in a capillary tube of a microfluidic device. Also described are methods of modulating liquid flow in a capillary tube by forming and removing a blood-clot microvalve.
Wavelet analysis of the impedance cardiogram waveforms
NASA Astrophysics Data System (ADS)
Podtaev, S.; Stepanov, R.; Dumler, A.; Chugainov, S.; Tziberkin, K.
2012-12-01
Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt)max) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.
Prakash, J A J; Kavitha, M L; Mathai, E
2011-01-01
Scrub typhus is a zoonotic illness endemic in the Asia-Pacific region. Early diagnosis and appropriate management contribute significantly to preventing adverse outcomes including mortality. Serology is widely used for diagnosing scrub typhus. Recent reports suggest that polymerase chain reaction (PCR) could be a rapid and reliable alternative. This study assessed the utility of these tests for scrub typhus diagnosis. Nested PCR to detect the 56 kDa antigen gene of O. tsutsugamushi was performed on blood clots from 87 individuals with clinically suspected scrub typhus. Weil-Felix test and scrub typhus IgM ELISA were performed on serum samples from the same patients. As a gold standard reference test was not available, latent class analysis (LCA) was used to assess the performance of the three tests. The LCA analysis showed the sensitivity of Weil-Felix test, IgM ELISA and PCR to be 59%, 100% and 58% respectively. The specificity of ELISA was only 73%, whereas those of the Weil-Felix test and PCR were 94% and 100% respectively. Nested PCR using blood clots while specific, lacked sensitivity as compared to IgM ELISA. In resource-poor settings Weil-Felix test still remains valuable despite its moderate sensitivity.
The Influence of Measurement Methodology on the Accuracy of Electrical Waveform Distortion Analysis
NASA Astrophysics Data System (ADS)
Bartman, Jacek; Kwiatkowski, Bogdan
2018-04-01
The present paper covers a review of documents that specify measurement methods of voltage waveform distortion. It also presents measurement stages of waveform components that are uncommon in the classic fundamentals of electrotechnics and signal theory, including the creation process of groups and subgroups of harmonics and interharmonics. Moreover, the paper discusses selected distortion factors of periodic waveforms and presents analyses that compare the values of these distortion indices. The measurements were carried out in the cycle per cycle mode and the measurement methodology that was used complies with the IEC 61000-4-7 norm. The studies showed significant discrepancies between the values of analyzed parameters.
21 CFR 864.7275 - Euglobulin lysis time tests.
Code of Federal Regulations, 2012 CFR
2012-04-01
... time required for the lysis (dissolution) of a clot formed from fibrinogen in the euglobulin fraction (that fraction of the plasma responsible for the formation of plasmin, a clot lysing enzyme). This test evaluates natural fibrinolysis (destruction of a blood clot after bleeding has been arrested). The test also...
21 CFR 864.7275 - Euglobulin lysis time tests.
Code of Federal Regulations, 2013 CFR
2013-04-01
... time required for the lysis (dissolution) of a clot formed from fibrinogen in the euglobulin fraction (that fraction of the plasma responsible for the formation of plasmin, a clot lysing enzyme). This test evaluates natural fibrinolysis (destruction of a blood clot after bleeding has been arrested). The test also...
21 CFR 864.7275 - Euglobulin lysis time tests.
Code of Federal Regulations, 2011 CFR
2011-04-01
... time required for the lysis (dissolution) of a clot formed from fibrinogen in the euglobulin fraction (that fraction of the plasma responsible for the formation of plasmin, a clot lysing enzyme). This test evaluates natural fibrinolysis (destruction of a blood clot after bleeding has been arrested). The test also...
21 CFR 864.7275 - Euglobulin lysis time tests.
Code of Federal Regulations, 2014 CFR
2014-04-01
... time required for the lysis (dissolution) of a clot formed from fibrinogen in the euglobulin fraction (that fraction of the plasma responsible for the formation of plasmin, a clot lysing enzyme). This test evaluates natural fibrinolysis (destruction of a blood clot after bleeding has been arrested). The test also...
42 CFR 410.63 - Hepatitis B vaccine and blood clotting factors: Conditions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Hepatitis B vaccine and blood clotting factors... Other Health Services § 410.63 Hepatitis B vaccine and blood clotting factors: Conditions... under § 410.10, subject to the specified conditions: (a) Hepatitis B vaccine: Conditions. Effective...
Fu, Chih-Yuan; Shih, Chun-Han; Chang, Po-Yen; Hsiao, Chi-Hao; Wang, Yu-Chun; Chen, Ray-Jade
2012-12-01
Most extraperitoneal bladder ruptures can be treated conservatively with catheter drainage only. However, in patients with concomitant intrabladder blood clot formation and extraperitoneal bladder rupture, surgery for blood clot evacuation and bladder repair are usually needed due to occlusion of the urinary catheter. In our patient, we used a ureteral catheter to bypass the clots in the bladder to provide adequate urinary drainage. This procedure serves as a valuable tool in the conservative treatment of extraperitoneal bladder injury.
Kumar, Santosh; Singh, Shivanshu; Parmar, Kalpesh Mahesh; Garg, Nitin
2014-01-01
Clot anuria in a solitary functioning kidney is an emergency situation. Haematuria with clot anuria in an early postoperative period represents a challenge, as treatment options are limited. Manipulation of the anastomotic site may lead to anastomotic disruption and urinoma while use of thrombolytic therapy poses the danger of increasing haematuria. We report a case of anuria due to clot retention in the upper tract following laparoscopic dismembered pyeloplasty in a solitary functioning kidney, managed successfully with double guide wire technique. PMID:25540210
Burke, Emily L; Walvekar, Rohan R; Lin, James; Hagan, Joseph; Kluka, Evelyn A
2009-12-01
To determine the efficacy of common solutions used to dissolve blood clots blocking tympanostomy tubes (TTs) of differing lengths and diameters. An ex vivo experimental study. Ear models were built by the study investigator. Tympanostomy tubes were inserted into the models and blocked with blood clots. Test solutions were applied to the blood clots, and time for clearance was recorded via microscopic visual confirmation. Richards T-tube had higher odds of unclogging than collar button tubes (odds ratio: 2.37, 95% confidence intervals 1.02-5.54, p=0.042). Vinegar and 3% hydrogen peroxide were most effective for Richards T-tubes and collar button tubes, respectively. Common solutions (vinegar and hydrogen peroxide) were more effective than antibiotic drops in clearing blood clot blocking TTs.
Circulating Microparticles Alter Formation, Structure, and Properties of Fibrin Clots.
Zubairova, Laily D; Nabiullina, Roza M; Nagaswami, Chandrasekaran; Zuev, Yuriy F; Mustafin, Ilshat G; Litvinov, Rustem I; Weisel, John W
2015-12-04
Despite the importance of circulating microparticles in haemostasis and thrombosis, there is limited evidence for potential causative effects of naturally produced cell-derived microparticles on fibrin clot formation and its properties. We studied the significance of blood microparticles for fibrin formation, structure, and susceptibility to fibrinolysis by removing them from platelet-free plasma using filtration. Clots made in platelet-free and microparticle-depleted plasma samples from the same healthy donors were analyzed in parallel. Microparticles accelerate fibrin polymerisation and support formation of more compact clots that resist internal and external fibrinolysis. These variations correlate with faster thrombin generation, suggesting thrombin-mediated kinetic effects of microparticles on fibrin formation, structure, and properties. In addition, clots formed in the presence of microparticles, unlike clots from the microparticle-depleted plasma, contain 0.1-0.5-μm size granular and CD61-positive material on fibres, suggesting that platelet-derived microparticles attach to fibrin. Therefore, the blood of healthy individuals contains functional microparticles at the levels that have a procoagulant potential. They affect the structure and stability of fibrin clots indirectly through acceleration of thrombin generation and through direct physical incorporation into the fibrin network. Both mechanisms underlie a potential role of microparticles in haemostasis and thrombosis as modulators of fibrin formation, structure, and resistance to fibrinolysis.
Circulating Microparticles Alter Formation, Structure, and Properties of Fibrin Clots
Zubairova, Laily D.; Nabiullina, Roza M.; Nagaswami, Chandrasekaran; Zuev, Yuriy F.; Mustafin, Ilshat G.; Litvinov, Rustem I.; Weisel, John W.
2015-01-01
Despite the importance of circulating microparticles in haemostasis and thrombosis, there is limited evidence for potential causative effects of naturally produced cell-derived microparticles on fibrin clot formation and its properties. We studied the significance of blood microparticles for fibrin formation, structure, and susceptibility to fibrinolysis by removing them from platelet-free plasma using filtration. Clots made in platelet-free and microparticle-depleted plasma samples from the same healthy donors were analyzed in parallel. Microparticles accelerate fibrin polymerisation and support formation of more compact clots that resist internal and external fibrinolysis. These variations correlate with faster thrombin generation, suggesting thrombin-mediated kinetic effects of microparticles on fibrin formation, structure, and properties. In addition, clots formed in the presence of microparticles, unlike clots from the microparticle-depleted plasma, contain 0.1–0.5-μm size granular and CD61-positive material on fibres, suggesting that platelet-derived microparticles attach to fibrin. Therefore, the blood of healthy individuals contains functional microparticles at the levels that have a procoagulant potential. They affect the structure and stability of fibrin clots indirectly through acceleration of thrombin generation and through direct physical incorporation into the fibrin network. Both mechanisms underlie a potential role of microparticles in haemostasis and thrombosis as modulators of fibrin formation, structure, and resistance to fibrinolysis. PMID:26635081
Anand, S; Kudallur, V; Pitman, E B; Diamond, S L
1997-01-01
A transport-reaction model describing penetration of plasmin by diffusion and permeation into a dissolving fibrin gel was solved numerically to explore mechanisms that lead to the formation and growth of dissolution fingers through blood clots during thrombolytic therapy. Under conditions of fluid permeation driven by arterial pressures, small random spatial variations in the initial fibrin density within clots (+/-4 to 25% peak variations) were predicted by the simulation to result in dramatic dissolution fingers that grew in time. With in vitro experiments, video microscopy revealed that the shape of the proximal face of a fibrin gel, when deformed by pressure-driven permeation, led to lytic breakthrough in the center of the clot, consistent with model predictions of increased velocities in this region leading to cannulation. Computer simulation of lysis of fibrin retracted by platelets (where more permeable regions are expected in the middle of the clot due to retraction) predicted cannulation of the clot during thrombolysis. This residual, annular thrombus was predicted to lyse more slowly, because radial pressure gradients to drive inner clot permeation were quite small. In conjunction with kinetic models of systemic pharmacodynamics and plasminogen activation biochemistry, a two-dimensional transport-reaction model can facilitate the prediction of the time and causes of clot cannulation, poor reperfusion, and embolism during thrombolysis.
Mechanics and contraction dynamics of single platelets and implications for clot stiffening
NASA Astrophysics Data System (ADS)
Lam, Wilbur A.; Chaudhuri, Ovijit; Crow, Ailey; Webster, Kevin D.; Li, Tai-De; Kita, Ashley; Huang, James; Fletcher, Daniel A.
2011-01-01
Platelets interact with fibrin polymers to form blood clots at sites of vascular injury. Bulk studies have shown clots to be active materials, with platelet contraction driving the retraction and stiffening of clots. However, neither the dynamics of single-platelet contraction nor the strength and elasticity of individual platelets, both of which are important for understanding clot material properties, have been directly measured. Here we use atomic force microscopy to measure the mechanics and dynamics of single platelets. We find that platelets contract nearly instantaneously when activated by contact with fibrinogen and complete contraction within 15 min. Individual platelets can generate an average maximum contractile force of 29 nN and form adhesions stronger than 70 nN. Our measurements show that when exposed to stiffer microenvironments, platelets generated higher stall forces, which indicates that platelets may be able to contract heterogeneous clots more uniformly. The high elasticity of individual platelets, measured to be 10 kPa after contraction, combined with their high contractile forces, indicates that clots may be stiffened through direct reinforcement by platelets as well as by strain stiffening of fibrin under tension due to platelet contraction. These results show how the mechanosensitivity and mechanics of single cells can be used to dynamically alter the material properties of physiologic systems.
Caseinolytic and milk-clotting activities from Moringa oleifera flowers.
Pontual, Emmanuel V; Carvalho, Belany E A; Bezerra, Ranilson S; Coelho, Luana C B B; Napoleão, Thiago H; Paiva, Patrícia M G
2012-12-01
This work reports the detection and characterization of caseinolytic and milk-clotting activities from Moringa oleifera flowers. Proteins extracted from flowers were precipitated with 60% ammonium sulphate. Caseinolytic activity of the precipitated protein fraction (PP) was assessed using azocasein, as well as α(s)-, β- and κ-caseins as substrates. Milk-clotting activity was analysed using skim milk. The effects of heating (30-100°C) and pH (3.0-11.0) on enzyme activities were determined. Highest caseinolytic activity on azocasein was detected after previous incubation of PP at pH 4.0 and after heating at 50°C. Milk-clotting activity, detected only in the presence of CaCl(2), was highest at incubation of PP at pH 3.0 and remained stable up to 50°C. The pre-treatment of milk at 70°C resulted in highest clotting activity. Enzyme assays in presence of protease inhibitors indicated the presence of aspartic, cysteine, serine and metallo proteases. Aspartic proteases appear to be the main enzymes involved in milk-clotting activity. PP promoted extensive cleavage of κ-casein and low level of α(s)- and β-caseins hydrolysis. The milk-clotting activity indicates the application of M. oleifera flowers in dairy industry. Copyright © 2012 Elsevier Ltd. All rights reserved.
On the accuracy and precision of numerical waveforms: effect of waveform extraction methodology
NASA Astrophysics Data System (ADS)
Chu, Tony; Fong, Heather; Kumar, Prayush; Pfeiffer, Harald P.; Boyle, Michael; Hemberger, Daniel A.; Kidder, Lawrence E.; Scheel, Mark A.; Szilagyi, Bela
2016-08-01
We present a new set of 95 numerical relativity simulations of non-precessing binary black holes (BBHs). The simulations sample comprehensively both black-hole spins up to spin magnitude of 0.9, and cover mass ratios 1-3. The simulations cover on average 24 inspiral orbits, plus merger and ringdown, with low initial orbital eccentricities e\\lt {10}-4. A subset of the simulations extends the coverage of non-spinning BBHs up to mass ratio q = 10. Gravitational waveforms at asymptotic infinity are computed with two independent techniques: extrapolation and Cauchy characteristic extraction. An error analysis based on noise-weighted inner products is performed. We find that numerical truncation error, error due to gravitational wave extraction, and errors due to the Fourier transformation of signals with finite length of the numerical waveforms are of similar magnitude, with gravitational wave extraction errors dominating at noise-weighted mismatches of ˜ 3× {10}-4. This set of waveforms will serve to validate and improve aligned-spin waveform models for gravitational wave science.
Lawrence, Matthew James; Marsden, Nick; Kaczynski, Jakub; Davies, Gareth; Davies, Nia; Hawkins, Karl; Perumal, Sounder; Brown, Martin Rowan; Morris, Keith; Davidson, Simon J; Williams, Phylip Rhodri; Evans, Phillip Adrian
2016-11-01
Balancing the beneficial effects of resuscitation fluids against their detrimental effect on hemostasis is an important clinical issue. We aim to compare the in vitro effects of 3 different colloid resuscitation fluids (4.5% albumin, hydroxyethyl starch [Voluven 6%], and gelatin [Geloplasma]) on clot microstructure formation using a novel viscoelastic technique, the gel point. This novel hemorheologic technique measures the biophysical properties of the clot and provides an assessment of clot microstructure from its viscoelastic properties. Importantly, in contrast to many assays in routine clinical use, the measurement is performed using unadulterated whole blood in a near-patient setting and provides rapid assessment of coagulation. We hypothesized that different colloids will have a lesser or greater detrimental effect on clot microstructure formation when compared against each other. Healthy volunteers were recruited into the study (n = 104), and a 20-mL sample of whole blood was obtained. Each volunteer was assigned to 1 of the 3 fluids, and the sample was diluted to 1 of 5 different dilutions (baseline, 10%, 20%, 40%, and 60%). The blood was tested using the gel point technique, which measures clot mechanical strength and quantifies clot microstructure (df) at the incipient stages of fibrin formation. df and clot mechanical strength decrease with progressive dilution for all 3 fluids. A significant reduction in df from baseline was recorded at dilutions of 20% for albumin (P < .0001), 40% for starch (P < .0001), and 60% for gelatin (P < .0001). We also observed significant differences, in terms of df, when comparing the different types of colloid (P < .0001). We found that albumin dilution produced the largest changes in clot microstructure, providing the lowest values of df (= 1.41 ± 0.061 at 60% dilution) compared with starch (1.52 ± 0.081) and gelatin (1.58 ± 0.063). We show that dilution with all 3 fluids has a significant effect on coagulation at even relatively low dilution volumes (20% and 40%). Furthermore, we quantify, using a novel viscoelastic technique, how the physiochemical properties of the 3 colloids exert individual changes on clot microstructure.
NASA Technical Reports Server (NTRS)
Chen, F.; Haber, E.; Matsueda, G. R.
1992-01-01
The binding of radiolabeled monoclonal antifibrin antibody 59D8 (specific for fibrin but not fibrinogen) to a series of degraded fibrin clots showed that the availability of the B beta(15-21) epitope (against which 59D8 had been raised) was inversely proportional to the extent of clot lysis. Examination of digest supernatants revealed that the B beta(15-21) epitope was released from clots as a high molecular weight degradation product in the presence of calcium ions but that the generation of low molecular weight peptides occurred in the absence of calcium ions. To address the question of epitope accessibility, we compared levels of fibrin clot binding among four radioactively labeled antibodies: antifibrin monoclonal antibody 59D8, two antifibrinogen monoclonal antibodies that cross-reacted with fibrin, and an affinity-purified polyclonal antifibrinogen antibody. We expected that the antifibrinogen antibodies would show enhanced binding to clots in comparison with the antifibrin antibody. However, the epitope accessibility experiments showed that all four antibody preparations bound fibrin clots at comparable levels. Taken together, these studies demonstrated that one fibrin-specific epitope, B beta(15-21), remains available on clots as they undergo degradation by plasmin and, importantly, that the epitope is not solubilized at a rate faster than the rate at which the clot is itself solubilized. The availability of the B beta(15-21) epitope during the course of plasminolysis assures the potential utility of antifibrin antibodies such as 59D8 for detecting thrombi and targeting plasminogen activators.
Quantification of intraventricular blood clot in MR-guided focused ultrasound surgery
NASA Astrophysics Data System (ADS)
Hess, Maggie; Looi, Thomas; Lasso, Andras; Fichtinger, Gabor; Drake, James
2015-03-01
Intraventricular hemorrhage (IVH) affects nearly 15% of preterm infants. It can lead to ventricular dilation and cognitive impairment. To ablate IVH clots, MR-guided focused ultrasound surgery (MRgFUS) is investigated. This procedure requires accurate, fast and consistent quantification of ventricle and clot volumes. We developed a semi-autonomous segmentation (SAS) algorithm for measuring changes in the ventricle and clot volumes. Images are normalized, and then ventricle and clot masks are registered to the images. Voxels of the registered masks and voxels obtained by thresholding the normalized images are used as seed points for competitive region growing, which provides the final segmentation. The user selects the areas of interest for correspondence after thresholding and these selections are the final seeds for region growing. SAS was evaluated on an IVH porcine model. SAS was compared to ground truth manual segmentation (MS) for accuracy, efficiency, and consistency. Accuracy was determined by comparing clot and ventricle volumes produced by SAS and MS, and comparing contours by calculating 95% Hausdorff distances between the two labels. In Two-One-Sided Test, SAS and MS were found to be significantly equivalent (p < 0.01). SAS on average was found to be 15 times faster than MS (p < 0.01). Consistency was determined by repeated segmentation of the same image by both SAS and manual methods, SAS being significantly more consistent than MS (p < 0.05). SAS is a viable method to quantify the IVH clot and the lateral brain ventricles and it is serving in a large-scale porcine study of MRgFUS treatment of IVH clot lysis.
Pulsed focused ultrasound-induced displacements in confined in vitro blood clots.
Wright, Cameron C; Hynynen, Kullervo; Goertz, David E
2012-03-01
Ultrasound has been shown to potentiate the effects of tissue plasminogen activator to improve clot lysis in a range of in vitro and in vivo studies as well as in clinical trials. One possible mechanism of action is acoustic radiation force-induced clot displacements. In this study, we investigate the temporal and spatial dynamics of clot displacements and strain initiated by focused ultrasound pulses. Displacements were produced by a 1.51 MHz f-number 1 transducer over a range of acoustic powers (1-85 W) in clots constrained within an agar vessel phantom channel. Displacements were tracked during and after a 5.45 ms therapy pulse using a 20 MHz high-frequency ultrasound imaging probe. Peak thrombus displacements were found to be linear as a function of acoustic power up to 60 W before leveling off near 128 μm for the highest transmit powers. The time to peak displacement and recovery time of blood clots was largely independent of acoustic powers with measured values near 2 ms. A linear relationship between peak axial strain and transmit power was observed, reaching a peak value of 11% at 35 W. The peak strain occurred ~0.75 mm from the focal zone for all powers investigated in both lateral and axial directions. These results indicate that substantial displacements can be induced by focused ultrasound in confined blood clots, and that the spatial and temporal displacement patterns are complex and highly dependent on exposure conditions, which has implications for future work investigating their link to clot lysis and for developing approaches to exploit these effects.
Rediscovering the wound hematoma as a site of hemostasis during major arterial hemorrhage.
White, N J; Mehic, E; Wang, X; Chien, D; Lim, E; St John, A E; Stern, S A; Mourad, P D; Rieger, M; Fries, D; Martinowitz, U
2015-12-01
Treatments for major internal bleeding after injury include permissive hypotension to decrease the rate of blood loss, intravenous infusion of plasma or clotting factors to improve clot formation, and rapid surgical hemostasis or arterial embolization to control bleeding vessels. Yet, little is known regarding major internal arterial hemostasis, or how these commonly used treatments might influence hemostasis. (i) To use a swine model of femoral artery bleeding to understand the perivascular hemostatic response to contained arterial hemorrhage. (ii) To directly confirm the association between hemodynamics and bleeding velocity. (iii) To observe the feasibility of delivering an activated clotting factor directly to internal sites of bleeding using a simplified angiographic approach. Ultrasound was used to measure bleeding velocity and in vivo clot formation by elastography in a swine model of contained femoral artery bleeding with fluid resuscitation. A swine model of internal pelvic and axillary artery hemorrhage was also used to demonstrate the feasibility of local delivery of an activated clotting factor. In this model, clots formed slowly within the peri-wound hematoma, but eventually contained the bleeding. Central hemodynamics correlated positively with bleeding velocity. Infusion of recombinant human activated factor VII into the injured artery near the site of major internal hemorrhage in the pelvis and axillae was feasible. We rediscovered that clot formation within the peri-wound hematoma is an integral component of hemostasis and a feasible target for the treatment of major internal bleeding using activated clotting factors delivered using a simplified angiographic approach. © 2015 International Society on Thrombosis and Haemostasis.
Endo, Hidenori; Endo, Toshiki; Nakagawa, Atsuhiro; Fujimura, Miki; Tominaga, Teiji
2017-07-01
In clipping surgery for aneurysmal subarachnoid hemorrhage (aSAH), critical steps include clot removal and dissection of aneurysms without premature rupture or brain injuries. To pursue this goal, a piezo actuator-driven pulsed water jet (ADPJ) system was introduced in this study. This study included 42 patients, who suffered aSAH and underwent clipping surgery. Eleven patients underwent surgery with the assistance of the ADPJ system (ADPJ group). In the other 31 patients, surgery was performed without the ADPJ system (Control group). The ADPJ system was used for clot removal and aneurysmal dissection. The clinical impact of the ADPJ system was judged by comparing the rate of premature rupture, degree of clot removal, and clinical outcomes. Intraoperatively, a premature rupture was encountered in 18.2 and 25.8% of cases in the ADPJ and control groups, respectively. Although the differences were not statistically significant, intraoperative observation suggested that the ADPJ system was effective in clot removal and dissection of aneurysms in a safe manner. Computed tomography scans indicated the achievement of higher degrees of clot removal, especially when the ADPJ system was used for cases with preoperative clot volumes of more than 25 ml (p = 0.047, Mann-Whitney U test). Clinical outcomes, including incidence of postoperative brain injury or symptomatic vasospasm, were similar in both groups. We described our preliminary surgical results using the ADPJ system for aSAH. Although further study is needed, the ADPJ system was considered a safe and effective tool for clot removal and dissection of aneurysms.
Orthogonal Chirp-Based Ultrasonic Positioning
Khyam, Mohammad Omar; Ge, Shuzhi Sam; Li, Xinde; Pickering, Mark
2017-01-01
This paper presents a chirp based ultrasonic positioning system (UPS) using orthogonal chirp waveforms. In the proposed method, multiple transmitters can simultaneously transmit chirp signals, as a result, it can efficiently utilize the entire available frequency spectrum. The fundamental idea behind the proposed multiple access scheme is to utilize the oversampling methodology of orthogonal frequency-division multiplexing (OFDM) modulation and orthogonality of the discrete frequency components of a chirp waveform. In addition, the proposed orthogonal chirp waveforms also have all the advantages of a classical chirp waveform. Firstly, the performance of the waveforms is investigated through correlation analysis and then, in an indoor environment, evaluated through simulations and experiments for ultrasonic (US) positioning. For an operational range of approximately 1000 mm, the positioning root-mean-square-errors (RMSEs) &90% error were 4.54 mm and 6.68 mm respectively. PMID:28448454
Orthogonal Chirp-Based Ultrasonic Positioning.
Khyam, Mohammad Omar; Ge, Shuzhi Sam; Li, Xinde; Pickering, Mark
2017-04-27
This paper presents a chirp based ultrasonic positioning system (UPS) using orthogonal chirp waveforms. In the proposed method, multiple transmitters can simultaneously transmit chirp signals, as a result, it can efficiently utilize the entire available frequency spectrum. The fundamental idea behind the proposed multiple access scheme is to utilize the oversampling methodology of orthogonal frequency-division multiplexing (OFDM) modulation and orthogonality of the discrete frequency components of a chirp waveform. In addition, the proposed orthogonal chirp waveforms also have all the advantages of a classical chirp waveform. Firstly, the performance of the waveforms is investigated through correlation analysis and then, in an indoor environment, evaluated through simulations and experiments for ultrasonic (US) positioning. For an operational range of approximately 1000 mm, the positioning root-mean-square-errors (RMSEs) &90% error were 4.54 mm and 6.68 mm respectively.
Wallops waveform analysis of SEASAT-1 radar altimeter data
NASA Technical Reports Server (NTRS)
Hayne, G. S.
1980-01-01
Fitting a six parameter model waveform to over ocean experimental data from the waveform samplers in the SEASAT-1 radar altimeter is described. The fitted parameters include a waveform risetime, skewness, and track point; from these can be obtained estimates of the ocean surface significant waveheight, the surface skewness, and a correction to the altimeter's on board altitude measurement, respectively. Among the difficulties encountered are waveform sampler gains differing from calibration mode data, and incorporating the actual SEASAT-1 sampled point target response in the fitted wave form. There are problems in using the spacecraft derived attitude angle estimates, and a different attitude estimator is developed. Points raised in this report have consequences for the SEASAT-1 radar altimeter's ocean surface measurements are for the design and calibration of radar altimeters in future oceanographic satellites.
Lewis, Jane Ea; Williams, Paul; Davies, Jane H
2016-01-01
This cross-sectional study aimed to individually and cumulatively compare sensitivity and specificity of the (1) ankle brachial index and (2) pulse volume waveform analysis recorded by the same automated device, with the presence or absence of peripheral arterial disease being verified by ultrasound duplex scan. Patients (n=205) referred for lower limb arterial assessment underwent ankle brachial index measurement and pulse volume waveform recording using volume plethysmography, followed by ultrasound duplex scan. The presence of peripheral arterial disease was recorded if ankle brachial index <0.9; pulse volume waveform was graded as 2, 3 or 4; or if haemodynamically significant stenosis >50% was evident with ultrasound duplex scan. Outcome measure was agreement between the measured ankle brachial index and interpretation of pulse volume waveform for peripheral arterial disease diagnosis, using ultrasound duplex scan as the reference standard. Sensitivity of ankle brachial index was 79%, specificity 91% and overall accuracy 88%. Pulse volume waveform sensitivity was 97%, specificity 81% and overall accuracy 85%. The combined sensitivity of ankle brachial index and pulse volume waveform was 100%, specificity 76% and overall accuracy 85%. Combining these two diagnostic modalities within one device provided a highly accurate method of ruling out peripheral arterial disease, which could be utilised in primary care to safely reduce unnecessary secondary care referrals.
Invadopodia formation in blood clots: Not so SLUGgish after all.
Knowles, Lynn M; Maranchie, Jodi K; Pilch, Jan
2014-01-01
Blood clotting specifically supports the metastatic dissemination of malignant cells to the lung. We have recently demonstrated that 2 tumor types that are prone to form lung metastases, renal cell carcinoma and soft tissue sarcoma, share specific adhesive mechanisms that support the invasion and colonization of blood clots in the pulmonary vasculature.
7 CFR 58.436 - Rennet, pepsin, other milk clotting enzymes and flavor enzymes.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Rennet, pepsin, other milk clotting enzymes and flavor enzymes. 58.436 Section 58.436 Agriculture Regulations of the Department of Agriculture (Continued... clotting enzymes and flavor enzymes. Enzyme preparations used in the manufacture of cheese shall be safe...
7 CFR 58.436 - Rennet, pepsin, other milk clotting enzymes and flavor enzymes.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false Rennet, pepsin, other milk clotting enzymes and flavor enzymes. 58.436 Section 58.436 Agriculture Regulations of the Department of Agriculture (Continued... clotting enzymes and flavor enzymes. Enzyme preparations used in the manufacture of cheese shall be safe...
7 CFR 58.436 - Rennet, pepsin, other milk clotting enzymes and flavor enzymes.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false Rennet, pepsin, other milk clotting enzymes and flavor enzymes. 58.436 Section 58.436 Agriculture Regulations of the Department of Agriculture (Continued... clotting enzymes and flavor enzymes. Enzyme preparations used in the manufacture of cheese shall be safe...
7 CFR 58.436 - Rennet, pepsin, other milk clotting enzymes and flavor enzymes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Rennet, pepsin, other milk clotting enzymes and flavor enzymes. 58.436 Section 58.436 Agriculture Regulations of the Department of Agriculture (Continued... clotting enzymes and flavor enzymes. Enzyme preparations used in the manufacture of cheese shall be safe...
7 CFR 58.436 - Rennet, pepsin, other milk clotting enzymes and flavor enzymes.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Rennet, pepsin, other milk clotting enzymes and flavor enzymes. 58.436 Section 58.436 Agriculture Regulations of the Department of Agriculture (Continued... clotting enzymes and flavor enzymes. Enzyme preparations used in the manufacture of cheese shall be safe...
42 CFR 410.63 - Hepatitis B vaccine and blood clotting factors: Conditions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Hepatitis B vaccine and blood clotting factors... Other Health Services § 410.63 Hepatitis B vaccine and blood clotting factors: Conditions. Notwithstanding the exclusion from coverage of vaccines (see § 405.310 of this chapter) and self-administered...
42 CFR 410.63 - Hepatitis B vaccine and blood clotting factors: Conditions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Hepatitis B vaccine and blood clotting factors... Other Health Services § 410.63 Hepatitis B vaccine and blood clotting factors: Conditions. Notwithstanding the exclusion from coverage of vaccines (see § 405.310 of this chapter) and self-administered...
42 CFR 410.63 - Hepatitis B vaccine and blood clotting factors: Conditions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Hepatitis B vaccine and blood clotting factors... Other Health Services § 410.63 Hepatitis B vaccine and blood clotting factors: Conditions. Notwithstanding the exclusion from coverage of vaccines (see § 405.310 of this chapter) and self-administered...
42 CFR 410.63 - Hepatitis B vaccine and blood clotting factors: Conditions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Hepatitis B vaccine and blood clotting factors... Other Health Services § 410.63 Hepatitis B vaccine and blood clotting factors: Conditions. Notwithstanding the exclusion from coverage of vaccines (see § 405.310 of this chapter) and self-administered...
Aboul-Enein, Basil H; Puddy, William
2016-08-01
This paper reviews the selected historiographic and contemporary literature that discussed the medical and public health contribution of Antoine Barthélémy Clot (Clot Bey) and how these contributions shaped modern public health in Ottoman Egypt, and the major features that led to the development of the public health infrastructure of early modern Egypt based on the contributions of Clot Bey. The literature discussed the establishment of Egypt's first modern public health and medical schools under the direct administration and guidance of Clot Bey, and his major contribution in the fields of vaccination, quarantine, the development of a culturally congruent curriculum for medical students, and the public health policies and practices enacted during the reign of Muhammad Ali Pasha that addressed major communicable diseases affecting Egypt. With considerable support from the viceroy of Egypt despite popular resistance, Clot Bey significantly modernized Egyptian medicine, medical education and reformed the public health infrastructure. He became one of the preeminent medical figures of nineteenth century Ottoman Egypt. © The Author(s) 2016.
Toward a computational model of hemostasis
NASA Astrophysics Data System (ADS)
Leiderman, Karin; Danes, Nicholas; Schoeman, Rogier; Neeves, Keith
2017-11-01
Hemostasis is the process by which a blood clot forms to prevent bleeding at a site of injury. The formation time, size and structure of a clot depends on the local hemodynamics and the nature of the injury. Our group has previously developed computational models to study intravascular clot formation, a process confined to the interior of a single vessel. Here we present the first stage of an experimentally-validated, computational model of extravascular clot formation (hemostasis) in which blood through a single vessel initially escapes through a hole in the vessel wall and out a separate injury channel. This stage of the model consists of a system of partial differential equations that describe platelet aggregation and hemodynamics, solved via the finite element method. We also present results from the analogous, in vitro, microfluidic model. In both models, formation of a blood clot occludes the injury channel and stops flow from escaping while blood in the main vessel retains its fluidity. We discuss the different biochemical and hemodynamic effects on clot formation using distinct geometries representing intra- and extravascular injuries.
Fetal electrocardiogram (ECG) for fetal monitoring during labour.
Neilson, James P
2015-12-21
Hypoxaemia during labour can alter the shape of the fetal electrocardiogram (ECG) waveform, notably the relation of the PR to RR intervals, and elevation or depression of the ST segment. Technical systems have therefore been developed to monitor the fetal ECG during labour as an adjunct to continuous electronic fetal heart rate monitoring with the aim of improving fetal outcome and minimising unnecessary obstetric interference. To compare the effects of analysis of fetal ECG waveforms during labour with alternative methods of fetal monitoring. The Cochrane Pregnancy and Childbirth Group's Trials Register (latest search 23 September 2015) and reference lists of retrieved studies. Randomised trials comparing fetal ECG waveform analysis with alternative methods of fetal monitoring during labour. One review author independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. One review author assessed the quality of the evidence using the GRADE approach. Seven trials (27,403 women) were included: six trials of ST waveform analysis (26,446 women) and one trial of PR interval analysis (957 women). The trials were generally at low risk of bias for most domains and the quality of evidence for ST waveform analysis trials was graded moderate to high. In comparison to continuous electronic fetal heart rate monitoring alone, the use of adjunctive ST waveform analysis made no obvious difference to primary outcomes: births by caesarean section (risk ratio (RR) 1.02, 95% confidence interval (CI) 0.96 to 1.08; six trials, 26,446 women; high quality evidence); the number of babies with severe metabolic acidosis at birth (cord arterial pH less than 7.05 and base deficit greater than 12 mmol/L) (average RR 0.72, 95% CI 0.43 to 1.20; six trials, 25,682 babies; moderate quality evidence); or babies with neonatal encephalopathy (RR 0.61, 95% CI 0.30 to 1.22; six trials, 26,410 babies; high quality evidence). There were, however, on average fewer fetal scalp samples taken during labour (average RR 0.61, 95% CI 0.41 to 0.91; four trials, 9671 babies; high quality evidence) although the findings were heterogeneous and there were no data from the largest trial (from the USA). There were marginally fewer operative vaginal births (RR 0.92, 95% CI 0.86 to 0.99; six trials, 26,446 women); but no obvious difference in the number of babies with low Apgar scores at five minutes or babies requiring neonatal intubation, or babies requiring admission to the special care unit (RR 0.96, 95% CI 0.89 to 1.04, six trials, 26,410 babies; high quality evidence). There was little evidence that monitoring by PR interval analysis conveyed any benefit of any sort. The modest benefits of fewer fetal scalp samplings during labour (in settings in which this procedure is performed) and fewer instrumental vaginal births have to be considered against the disadvantages of needing to use an internal scalp electrode, after membrane rupture, for ECG waveform recordings. We found little strong evidence that ST waveform analysis had an effect on the primary outcome measures in this systematic review.There was a lack of evidence showing that PR interval analysis improved any outcomes; and a larger future trial may possibly demonstrate beneficial effects.There is little information about the value of fetal ECG waveform monitoring in preterm fetuses in labour. Information about long-term development of the babies included in the trials would be valuable.
Micro-elastometry on whole blood clots using actuated surface-attached posts (ASAPs).
Judith, Robert M; Fisher, Jay K; Spero, Richard Chasen; Fiser, Briana L; Turner, Adam; Oberhardt, Bruce; Taylor, R M; Falvo, Michael R; Superfine, Richard
2015-03-07
We present a novel technology for microfluidic elastometry and demonstrate its ability to measure stiffness of blood clots as they form. A disposable micro-capillary strip draws small volumes (20 μL) of whole blood into a chamber containing a surface-mounted micropost array. The posts are magnetically actuated, thereby applying a shear stress to the blood clot. The posts' response to magnetic field changes as the blood clot forms; this response is measured by optical transmission. We show that a quasi-static model correctly predicts the torque applied to the microposts. We experimentally validate the ability of the system to measure clot stiffness by correlating our system with a commercial thromboelastograph. We conclude that actuated surface-attached post (ASAP) technology addresses a clinical need for point-of-care and small-volume elastic haemostatic assays.
Konya, Judit; Al Qaissi, Ahmed; Sathyapalan, Thozhukat; Ajjan, Ramzi; Madden, Leigh; Naseem, Khalid M; Garrett, Andrew Thomas; Kilpatrick, Eric; Atkin, Stephen L
2018-01-01
To determine if clotting, platelet, and endothelial function were affected by simulated short-haul commercial air flight conditions (SF) in participants with type 2 diabetes (T2DM) compared to controls. 10 participants with T2DM (7 females, 3 males) and 10 controls (3 females, 7 males) completed the study. Participants were randomized to either spend 2 h in an environmental chamber at sea level conditions (temperature: 23°C, oxygen concentration 21%, humidity 45%), or subject to a simulated 2-h simulated flight (SF: temperature: 23°C, oxygen concentration 15%, humidity 15%), and crossed over 7 days later. Main outcome measures: clot formation and clot lysis parameters, functional platelet activation markers, and endothelial function measured by reactive hyperemia index (RHI) by EndoPAT and serum microparticles. Comparing baseline with SF conditions, clot maximal absorption was increased in controls (0.375 ± 0.05 vs. 0.39 ± 0.05, p < 0.05) and participants with T2DM (0.378 ± 0.089 vs. 0.397 ± 0.089, p < 0.01), while increased basal platelet activation for both fibrinogen binding and P-selectin expression ( p < 0.05) was seen in participants with T2DM. Parameters of clot formation and clot lysis, stimulated platelet function (stimulated platelet response to ADP and sensitivity to prostacyclin), and endothelial function were unchanged. While SF resulted in the potential of denser clot formation with enhanced basal platelet activation in T2DM, the dynamic clotting, platelet, and endothelial markers were not affected, suggesting that short-haul commercial flying adds no additional hazard for venous thromboembolism for participants with T2DM compared to controls.
Automated seismic waveform location using Multichannel Coherency Migration (MCM)-I. Theory
NASA Astrophysics Data System (ADS)
Shi, Peidong; Angus, Doug; Rost, Sebastian; Nowacki, Andy; Yuan, Sanyi
2018-03-01
With the proliferation of dense seismic networks sampling the full seismic wavefield, recorded seismic data volumes are getting bigger and automated analysis tools to locate seismic events are essential. Here, we propose a novel Multichannel Coherency Migration (MCM) method to locate earthquakes in continuous seismic data and reveal the location and origin time of seismic events directly from recorded waveforms. By continuously calculating the coherency between waveforms from different receiver pairs, MCM greatly expands the available information which can be used for event location. MCM does not require phase picking or phase identification, which allows fully automated waveform analysis. By migrating the coherency between waveforms, MCM leads to improved source energy focusing. We have tested and compared MCM to other migration-based methods in noise-free and noisy synthetic data. The tests and analysis show that MCM is noise resistant and can achieve more accurate results compared with other migration-based methods. MCM is able to suppress strong interference from other seismic sources occurring at a similar time and location. It can be used with arbitrary 3D velocity models and is able to obtain reasonable location results with smooth but inaccurate velocity models. MCM exhibits excellent location performance and can be easily parallelized giving it large potential to be developed as a real-time location method for very large datasets.
Computational Modeling of Blast Wave Transmission Through Human Ear.
Leckness, Kegan; Nakmali, Don; Gan, Rong Z
2018-03-01
Hearing loss has become the most common disability among veterans. Understanding how blast waves propagate through the human ear is a necessary step in the development of effective hearing protection devices (HPDs). This article presents the first 3D finite element (FE) model of the human ear to simulate blast wave transmission through the ear. The 3D FE model of the human ear consisting of the ear canal, tympanic membrane, ossicular chain, and middle ear cavity was imported into ANSYS Workbench for coupled fluid-structure interaction analysis in the time domain. Blast pressure waveforms recorded external to the ear in human cadaver temporal bone tests were applied at the entrance of the ear canal in the model. The pressure waveforms near the tympanic membrane (TM) in the canal (P1) and behind the TM in the middle ear cavity (P2) were calculated. The model-predicted results were then compared with measured P1 and P2 waveforms recorded in human cadaver ears during blast tests. Results show that the model-derived P1 waveforms were in an agreement with the experimentally recorded waveforms with statistic Kurtosis analysis. The FE model will be used for the evaluation of HPDs in future studies.
Kakajiwala, Aadil; Chiotos, Kathleen; Brothers, Julie; Lederman, April; Amaral, Sandra
2016-12-01
One of the greatest problems associated with continuous renal replacement therapy (CRRT) is the early clotting of filters. A literature search revealed three case reports of lipemic blood causing recurrent clotting and reduced CRRT circuit survival time in adult patients, but no reports of cases in children. A 23-month-old male infant with Martinez-Frias syndrome and multivisceral transplant was admitted to the hospital with severe sepsis and hemolytic anemia. He developed acute kidney injury, fluid overload and electrolyte imbalances requiring CRRT and was also administered total parenteral nutrition (TPN) and fat emulsion. The first circuit lasted 60 h before routine change was required. The second circuit showed acute clotting after only 18 h, and brownish-milky fluid was found in the circuit tubing layered between the clotted blood. The patient's serum triglyceride levels were elevated at 988 mg/dL. The lipid infusion was stopped and CRRT restarted. Serum triglyceride levels improved to 363 mg/dL. The new circuit lasted 63 h before routine change was required. Clotting of CRRT circuits due to elevated triglyceride levels is rare and has not been reported in the pediatric population. Physicians should be mindful of this risk in patients receiving TPN who have unexpected clotting of CRRT circuits.
Moringa oleifera Lam.: Protease activity against blood coagulation cascade
Satish, A; Sairam, Sudha; Ahmed, Faiyaz; Urooj, Asna
2012-01-01
Background: The present study evaluated the protease activity of aqueous extracts of Moringa oleifera (Moringaceae) leaf (MOL) and root (MOR). Materials and Methods: Protease activity was assayed using casein, human plasma clot and human fibrinogen as substrates. Results: Caseinolytic activity of MOL was significantly higher (P ≤ 0.05) than that of MOR. Similar observations were found in case of human plasma clot hydrolyzing activity, wherein MOL caused significantly higher (P ≤ 0.05) plasma clot hydrolysis than MOR. Zymographic techniques were used to detect proteolytic enzymes following electrophoretic separation in gels. Further, both the extracts exhibited significant procoagulant activity as reflected by a significant decrease (P ≤ 0.05) in recalcification time, accompanied by fibrinogenolytic and fibrinolytic activities; clotting time was decreased from 180 ± 10 sec to 119 ± 8 sec and 143 ± 10 sec by MOL and MOR, respectively, at a concentration of 2.5 mg/mL. Fibrinogenolytic (human fibrinogen) and fibrinolytic activity (human plasma clot) was determined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), plate method and colorimetric method. Zymographic profile indicated that both the extracts exerted their procoagulant activity by selectively hydrolyzing Aα and Bβ subunits of fibrinogen to form fibrin clot, thereby exhibiting fibrinogenolytic activity. However, prolonged incubation resulted in degradation of the formed fibrin clot, suggesting fibrinolytic like activity. Conclusions: These findings support the traditional usage of M. oleifera extracts for wound healing. PMID:22224061
Moringa oleifera Lam.: Protease activity against blood coagulation cascade.
Satish, A; Sairam, Sudha; Ahmed, Faiyaz; Urooj, Asna
2012-01-01
The present study evaluated the protease activity of aqueous extracts of Moringa oleifera (Moringaceae) leaf (MOL) and root (MOR). Protease activity was assayed using casein, human plasma clot and human fibrinogen as substrates. Caseinolytic activity of MOL was significantly higher (P ≤ 0.05) than that of MOR. Similar observations were found in case of human plasma clot hydrolyzing activity, wherein MOL caused significantly higher (P ≤ 0.05) plasma clot hydrolysis than MOR. Zymographic techniques were used to detect proteolytic enzymes following electrophoretic separation in gels. Further, both the extracts exhibited significant procoagulant activity as reflected by a significant decrease (P ≤ 0.05) in recalcification time, accompanied by fibrinogenolytic and fibrinolytic activities; clotting time was decreased from 180 ± 10 sec to 119 ± 8 sec and 143 ± 10 sec by MOL and MOR, respectively, at a concentration of 2.5 mg/mL. Fibrinogenolytic (human fibrinogen) and fibrinolytic activity (human plasma clot) was determined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), plate method and colorimetric method. Zymographic profile indicated that both the extracts exerted their procoagulant activity by selectively hydrolyzing Aα and Bβ subunits of fibrinogen to form fibrin clot, thereby exhibiting fibrinogenolytic activity. However, prolonged incubation resulted in degradation of the formed fibrin clot, suggesting fibrinolytic like activity. These findings support the traditional usage of M. oleifera extracts for wound healing.
NASA Astrophysics Data System (ADS)
Barba, Bin Jeremiah D.; Aranilla, Charito T.; Relleve, Lorna S.; Cruz, Veriza Rita C.; Vista, Jeanina Richelle; Abad, Lucille V.
2018-03-01
Uncontrolled hemorrhage remains a persistent problem especially in anatomical areas where compression and tourniquet cannot be applied. Hemostatic agents are materials which can achieve control of bleeding in acute, life-threatening traumatic coagulopathy. In this study, we prepared biocompatible hydrogel-based hemostat crosslinked by ionizing radiation. Granules made from carboxymethyl cellulose and dressing from kappa carrageenan and polyethylene oxide were characterized by FT-IR, SEM, and gel analysis. Gamma radiation with a dose of 25 kGy was used for sterilization process. Stability studies indicate that the products remain effective with a shelf life of up to 18 months based on accelerated aging. Both hemostatic agents were demonstrated to be effective in vitro blood clotting assays showing a low blood clotting index, high platelet adhesion capacity and accelerated clotting time. Hemostat granules and dressing were also used in a femoral artery rat bleeding model where hemorrhage control was achieved in 90 s without compression and resulted in 100% survival rate after a 7 and 14-day observation.
ELECTROMAGNETICALLY INDUCED DISTORTION OF A FIBRIN MATRIX WITH EMBEDDED MICROPARTICLES
SCOGIN, TYLER; YESUDASAN, SUMITH; WALKER, MITCHELL L. R.
2018-01-01
Blood clots occur in the human body when they are required to prevent bleeding. In pathological states such as diabetes and sickle cell disease, blood clots can also form undesirably due to hypercoagulable plasma conditions. With the continued effort in developing fibrin therapies for potential life-saving solutions, more mechanical modeling is needed to understand the properties of fibrin structures with inclusions. In this study, a fibrin matrix embedded with magnetic micro particles (MMPs) was subjected to a magnetic field to determine the magnitude of the required force to create plastic deformation within the fibrin clot. Using finite element (FE) analysis, we estimated the magnetic force from an electromagnet at a sample space located approximately 3 cm away from the coil center. This electromagnetic force coupled with gravity was applied on a fibrin mechanical system with MMPs to calculate the stresses and displacements. Using appropriate coil parameters, it was determined that application of a magnetic field of 730 A/m on the fibrin surface was necessary to achieve an electromagnetic force of 36 nN (to engender plastic deformation). PMID:29628543
2009-12-01
with 32 chip baseband waveforms such as Walsh functions. Performance with both coherent and noncoherent detection is analyzed. For noncoherent ...detection, only one five bit symbol is transmitted on the I and Q components of the carrier per symbol duration, so the data throughput for noncoherent ...for coherent and noncoherent demodulation, respectively, when 510bP . Likewise, in an AWGN only environment with a diversity of two, the proposed
Kushnir, Igal; Kushnir, Alon; Serena, Thomas E; Garfinkel, Doron
2016-09-01
The objective of this pilot study was to evaluate the efficacy and safety of a novel method using an autologous whole blood clot formed with the RedDress Wound Care System (RD1, RedDress Ltd, Israel), a provisional whole blood clot matrix used in the treatment of chronic wounds of various etiologies. Patients were treated at the bedside with the whole blood clot matrix. Blood was withdrawn from each patient using citrate, mixed with a calcium gluconate/kaolin suspension, and injected into an RD1 clotting tray. Within 10 minutes, a clot was formed, placed upon the wound, and fixed with primary and secondary dressings. Wounds were redressed weekly with a whole blood clot matrix. Treatment was terminated when complete healing was achieved, or when the clinician determined that the wound could not further improve without additional invasive procedures. Seven patients with multiple and serious comorbidities and 9 chronic wounds were treated with 35 clot matrices. Complete healing was achieved in 7 of 9 wounds (78%). In 1 venous ulcer with a nonhealing fistula, 77% healing was achieved. Treatment was terminated in 1 pressure ulcer at 82% closure, because an unexpected mechanical trauma resulted in deterioration; this was the only adverse event reported, unrelated to the product. No systemic adverse events occurred. This pilot study demonstrates the in vitro autologous whole blood clot matrix is effective and safe for treating patients with chronic wounds of different etiologies. A larger clinical trial is needed to assess the relative success rate of the matrix in different types of wounds in a diverse population with comorbidities.
Optical sensing of anticoagulation status: Towards point-of-care coagulation testing
Tripathi, Markandey M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.
2017-01-01
Anticoagulant overdose is associated with major bleeding complications. Rapid coagulation sensing may ensure safe and accurate anticoagulant dosing and reduce bleeding risk. Here, we report the novel use of Laser Speckle Rheology (LSR) for measuring anticoagulation and haemodilution status in whole blood. In the LSR approach, blood from 12 patients and 4 swine was placed in disposable cartridges and time-varying intensity fluctuations of laser speckle patterns were measured to quantify the viscoelastic modulus during clotting. Coagulation parameters, mainly clotting time, clot progression rate (α-angle) and maximum clot stiffness (MA) were derived from the clot viscoelasticity trace and compared with standard Thromboelastography (TEG). To demonstrate the capability for anticoagulation sensing in patients, blood samples from 12 patients treated with warfarin anticoagulant were analyzed. LSR clotting time correlated with prothrombin and activated partial thromboplastin time (r = 0.57–0.77, p<0.04) and all LSR parameters demonstrated good correlation with TEG (r = 0.61–0.87, p<0.04). To further evaluate the dose-dependent sensitivity of LSR parameters, swine blood was spiked with varying concentrations of heparin, argatroban and rivaroxaban or serially diluted with saline. We observed that anticoagulant treatments prolonged LSR clotting time in a dose-dependent manner that correlated closely with TEG (r = 0.99, p<0.01). LSR angle was unaltered by anticoagulation whereas TEG angle presented dose-dependent diminution likely linked to the mechanical manipulation of the clot. In both LSR and TEG, MA was largely unaffected by anticoagulation, and LSR presented a higher sensitivity to increased haemodilution in comparison to TEG (p<0.01). Our results establish that LSR rapidly and accurately measures the response of various anticoagulants, opening the opportunity for routine anticoagulation monitoring at the point-of-care or for patient self-testing. PMID:28771571
Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee
2017-07-01
For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.
Iliescu, M; Hoemann, C D; Shive, M S; Chenite, A; Buschmann, M D
2008-03-01
Chitosan-based polymers have been extensively studied for biomedical applications. Recently, liquid solutions of chitosan in a glycerol phosphate buffer (chitosan-GP) with physiological pH and osmolality were mixed with autologous blood to form hybrid chitosan-GP/blood implants that improved the repair of articular cartilage lesions in a large animal model. The mixture of chitosan-GP and blood forms a viscous liquid, which solidifies in minutes via normal blood coagulation as well as chitosan-mediated mechanisms. Here we have examined the ultrastructure of these chitosan-GP/blood clots as well as regular blood clots and chitosan-GP gels, the latter produced by heating. Both unfixed and fixed samples of chitosan-GP/blood clots, regular blood clots, and chitosan-GP gels were investigated by environmental scanning electron microscopy (ESEM) in conjunction with energy dispersive X-ray spectrometry (EDS), the former permitting direct observation of the ultrastructure in hydrated conditions simulating the natural state. By examination of unfixed specimens using ESEM we found that chitosan formed a network structure in both chitosan-GP gels and chitosan-GP/blood clots; however this structure was altered by aldehyde fixation to produce artifactual aggregates of chitosan microparticles. We were also able to identify chitosan in chitosan-GP/blood clots by washing samples in low concentration NaCl solutions followed by local EDS analyses to identify excess chloride versus sodium, and thus presence of cationic chitosan in analyzed features. Additional results indicated that the majority of glycerol phosphate diffuses freely from chitosan-GP gels (by EDS of phosphorus) and that hyperosmotic paraformaldehyde-based fixatives (i.e. 4% w/v) significantly disturb erythrocyte morphology in fixed whole blood clots. (c) 2007 Wiley-Liss, Inc.
Wang, Shoei-Shen; Chou, Nai-Kuan; Chung, Tze-Wen
2009-12-01
Accelerated thrombolysis by pressure-driven permeation has been demonstrated in in vitro and in vivo animal models by using plasminogen activators (PAs) encapsulated liposomes or PEG microparticles. Recent reports have also described acceleration of thrombolysis using tissue type PA (t-PA) encapsulated in PLGA nanoparticles (NPs) coated with chitosan (CS) or CS-GRGD by interactions between the NPs and blood clots. However, the permeation through and dissolving patterns in thrombolysis with the aforementioned microparticles or NPs, which may be clinically relevant to the recovery status of the posttreatments, have not been reported. Therefore, this work studied such phenomena in thrombolysis with t-PA encapsulated in NPs. The t-PA solution and the NPs exhibited distinctly different permeation patterns of dissolved clots. Plasma permeates through clots showed a stream flow or burst flow phenomena when lyzed with NPs shelled with CS or CS-GRGD, respectively, whereas a diffusion pattern was observed in those lyzed with t-PA solution. At the outlet position of clots, the clots dissolved with PLGA/CS and PLGA/CS-GRGD NPs revealed extremely rough surfaces to a depth of 100 mum, indicating that a cross-permeation direction of clot lysis occurred, while those dissolved with t-PA solution showed slightly rough surfaces to a depth of 12 mum. Permeation through and clot dissolution patterns of thrombolysis with t-PA encapsulated in NPs shelled with CS or CS-GRGD distinctly differed from those dissolved with t-PA solutions in this in vitro thrombolysis model, These findings may be relevant to posttreatment of patients with conventional PA thrombolysis. Copyright 2008 Wiley Periodicals, Inc.
Kim, Paul Y.; Vu, Trang T.; Leslie, Beverly A.; Stafford, Alan R.; Fredenburgh, James C.; Weitz, Jeffrey I.
2014-01-01
Fibrin (Fn) clots formed from γ′-fibrinogen (γ′-Fg), a variant with an elongated γ-chain, are resistant to lysis when compared with clots formed from the predominant γA-Fg, a finding previously attributed to differences in clot structure due to delayed thrombin-mediated fibrinopeptide (FP) B release or impaired cross-linking by factor XIIIa. We investigated whether slower lysis of γ′-Fn reflects delayed plasminogen (Pg) binding and/or activation by tissue plasminogen activator (tPA), reduced plasmin-mediated proteolysis of γ′-Fn, and/or altered cross-linking. Clots formed from γ′-Fg lysed more slowly than those formed from γA-Fg when lysis was initiated with tPA/Pg when FPA and FPB were both released, but not when lysis was initiated with plasmin, or when only FPA was released. Pg bound to γ′-Fn with an association rate constant 22% lower than that to γA-Fn, and the lag time for initiation of Pg activation by tPA was longer with γ′-Fn than with γA-Fn. Once initiated, however, Pg activation kinetics were similar. Factor XIIIa had similar effects on clots formed from both Fg isoforms. Therefore, slower lysis of γ′-Fn clots reflects delayed FPB release, which results in delayed binding and activation of Pg. When clots were formed from Fg mixtures containing more than 20% γ′-Fg, the upper limit of the normal level, the delay in lysis was magnified. These data suggest that circulating levels of γ′-Fg modulate the susceptibility of clots to lysis by slowing Pg activation by tPA and provide another example of the intimate connections between coagulation and fibrinolysis. PMID:25128532
NASA Astrophysics Data System (ADS)
Acconcia, Christopher N.
The occlusion of blood vessels by thrombus is a major cause of mortality and morbidity in cardiovascular diseases such as deep vein thrombosis, myocardial infarction and ischemic stroke. In these contexts, prompt restoration of blood flow is of the utmost importance and is poorly addressed by current methods in many cases. For example, the treatment standard for ischemic stroke is administration of the thrombolytic agent tissue plasminogen activator, which is only minimally effective and has associated safety issues. There is, therefore, a need for the development of alternative recanalization strategies and amongst these, bubble mediated sonothrombolysis (thrombolysis by ultrasound) has emerged as a promising approach. Though it is well established that ultrasound stimulated microbubbles can potentiate the lysis of blood clots, the mechanisms are not well understood and this lack of understanding is a hindrance to the development of improved ultrasound exposure strategies. This thesis has revealed insights into the mechanisms of bubble mediated sonothrombolysis which can be used to guide the development of improved exposure strategies and contrast agents (i.e. bubble sizes) for sonothrombolysis treatments. The experimental approach involved fast frame optical imaging of ultrasound stimulated microbubbles interacting with clots, and two-photon fluorescence imaging of clots following ultrasound exposure. It was demonstrated that bubbles can penetrate fibrin clots, disrupt the fibrin network, generate patent tunnels, enhance the transport of fluid into the clot and induce clot boundary displacements. Furthermore, the occurrence and extent of these therapeutically relevant effects were shown to be highly dependent on pulse length and bubble size: longer pulses and larger bubbles were associated with greater disruption of fibrin networks and greater fluid transport distances. Finally, it was shown that bubbles can induce the ejection of erythrocytes from blood clots and produce advanced erosion effects which depend on ultrasound exposure conditions.
Bank, Steffen; Nexø, Bjørn Andersen; Andersen, Vibeke; Vogel, Ulla; Andersen, Paal Skytt
2013-06-01
The recovery of biological samples for genetic epidemiological studies can be cumbersome. Blood clots are routinely collected for serological examinations. However, the extraction of DNA from blood clots can be difficult and often results in low yields. The aim was to compare the efficiency of commercial purification kits for extracting DNA from long-term frozen clotted blood. Serum tubes with clotted blood were stored at -20°C for 1 to 2.5 years before DNA extraction. DNA was extracted from 10 blood clot samples using PureGene (Qiagen) with and without glycogen, the QIAamp DNA Micro kit (Qiagen), and the Nucleospin 96 Blood kit (Macherey-Nagel). Furthermore, blood clots from 1055 inflammatory bowel disease patients were purified using the Maxwell 16 Blood purification kit (Promega). The DNA was extracted according to the manufacturers` instructions and real-time PCR and the A(260)/A(280) ratio were used to evaluate the quality of the extracted DNA. The highest DNA yield was obtained by the Maxwell 16 Blood purification kit (Promega) with a median of 4.90 μg (range 0.8-25 μg) pr 300 μL total blood. PureGene with glycogen (Qiagen) had the second highest yield with a median of 0.65 μg (range 0.5-2.6 μg) pr 300 μL total blood. The yield obtained by the different commercial kits varied considerably. Our work demonstrates that high-quality and -quantity DNA can be extracted with the Maxwell 16 Blood purification kit (Promega) from cryopreserved blood clots, even after prolonged storage. The recovered DNA served as a reliable PCR template for single-nucleotide polymorphism assays.
[Decreased retraction of blood clots in patients with venous thromboembolic complications].
Bredikhin, R A; Peshkova, A D; Maliasev, D V; Batrakova, M V; Le Min, J; Panasiuk, M V; Fatkhullina, L S; Ignat'ev, I M; Khaĭrullin, R N; Litvinov, R I
Haemostatic disorders play an important role in the pathogenesis of acute venous thrombosis. One of the least studied reactions of blood coagulation and thrombogenesis is spontaneous contraction of blood clots, which takes place at the expense of the contractility apparatus of activated blood platelets adhered to fibrin fibres. The work was aimed at studying the parameters of contraction of blood clots, formed in vitro, in blood of 41 patients with acute venous thromboses as compared with the same parameters in apparently healthy donors. We used a new instrumental method making it possible to determine the time from initiation to the beginning of contraction, as well as the degree and velocity of clot contraction. It was revealed that in patients with venous thrombosis the ability of clots to shrink was significantly reduced as compared with the control. We detected a statistically significant retardation of and decrease in of blood clot concentration in patients with venous thrombosis complicated by pulmonary artery thromboembolism as compared with contraction in patients with isolated deep vein thrombosis, witch may be important for early diagnosis and determination of the risk of thromboembolism. Besides, we revealed a statistically significant retardation of contraction in patients with proximal thrombosis as compared with contraction in patients with distal thrombosis, with similar values of the degree of contraction. Contraction was statistically significantly reduced in acute thrombosis (less than 21 days), whereas in subacute thrombosis (more than 21 days) the parameters of contraction were closer to normal values. The obtained findings suggest that reduction of blood clot contraction may be a new, hitherto unstudied pathogenetic mechanism deteriorating the course and outcome of venous thrombosis. The clinical significance of contraction and its impairments, as well as the diagnostic and prognostic value of the laboratory test for blood clot contraction would merit further study.
Roberts, Jonathan S; Niu, Jianli; Pastor-Cervantes, Juan A
2017-10-01
Hemostasis following transradial access (TRA) is usually achieved by mechanical compression. We investigated use of the QuikClot Radial hemostasis pad (Z-Medica) compared with the TR Band (Terumo Medical) to shorten hemostasis after TRA. Thirty patients undergoing TRA coronary angiography and/or percutaneous coronary intervention were randomized into three cohorts post TRA: 10 patients received mechanical compression with the TR Band, 10 patients received 30 min of compression with the QuikClot Radial pad, and 10 patients received 60 min of compression with the QuikClot Radial pad. Times to hemostasis and access-site complications were recorded. Radial artery patency was evaluated 1 hour after hemostasis by the reverse Barbeau's test. There were no differences in patient characteristics, mean dose of heparin (7117 ± 1054 IU), or mean activated clotting time value (210 ± 50 sec) at the end of procedure among the three groups. Successful hemostasis was achieved in 100% of patients with both the 30-min and 60-min compression groups using the QuikClot pad. Hemostasis failure occurred in 50% of patients when the TR Band was initially weaned at the protocol-driven time (40 min after sheath removal). Mean compression time for hemostasis with the TR Band was 149.4 min compared with 30.7 min and 60.9 min for the 30-min and 60-min QuikClot groups, respectively. No radial artery occlusion occurred in any subject at the end of the study. Use of the QuikClot Radial pad following TRA in this pilot trial significantly shortened hemostasis times when compared with the TR Band, with no increased complications noted.
Characterisation of clot microstructure properties in stable coronary artery disease.
Sabra, Ahmed; Lawrence, Matthew James; Aubrey, Robert; Obaid, Daniel; Chase, Alexander; Smith, Dave; Thomas, Phillip; Storton, Sharon; Davies, Gareth R; Hawkins, Karl; Williams, Phylip Rhodri; Morris, Keith; Evans, Phillip Adrian
2017-01-01
Coronary artery disease (CAD) is associated with an increased prothrombotic tendency and is also linked to unfavourably altered clot microstructure. We have previously described a biomarker of clot microstructure (d f ) that is unfavourably altered in acute myocardial infarction. The d f biomarker assesses whether the blood will form denser or looser microstructures when it clots. In this study we assessed in patients with stable chest pain whether d f can differentiate between obstructed and unobstructed CAD. A blood sample prior to angiography was obtained from 251 consecutive patients undergoing diagnostic coronary angiography. Patients were categorised based on angiographic findings as presence or absence of obstructive CAD (stenosis ≥50%). The blood sample was assessed using the d f biomarker, standard laboratory markers and platelet aggregometry (Multiplate). A significant difference (p=0.028) in d f was observed between obstructive CAD (1.748±0.057, n=83) and unobstructive CAD (1.732±0.052, n=168), where patients with significant CAD produce denser, more tightly packed clots. d f was also raised in men with obstructive CAD compared with women (1.745±0.055 vs 1.723±0.052, p=0.007). Additionally d f significantly correlated with the platelets response to arachidonic acid as measured by the ASPItest area under the curve readings from platelet aggregometry (correlation coefficient=0.166, p=0.008), a low value of the ASPItest indicating effective aspirin use was associated with looser, less dense clots. For the first time, we characterise clot microstructure, as measured by d f , in patients with stable CAD. d f can potentially be used to risk-stratify patients with stable CAD and assess the efficacy of therapeutic interventions by measuring changes in clot microstructure.
Sørensen, Benny; Asvaldsdottir, Hanna S; Gudmundsdottir, Brynja R; Onundarson, Pall T
2009-12-01
Cardiac surgery involving cardio pulmonary bypass (CPB) may be associated with development of a coagulopathy that increases risk of bleeding. In the present ex vivo study we investigated the influence of fibrinogen and rFVIIa, alone or in combination, on whole blood coagulation thromboelastometry using pre- and postoperative blood samples from 18 consecutive adult patients undergoing CPB surgery. Dynamic thromboelastometric clotting profiles were recorded using citrated whole blood activated with trace amounts of tissue factor (Innovin, final dilution 1:17000). Blood samples were collected before surgery (control) and postoperative samples were obtained following in vivo neutralization of heparin with protamine sulphate. All blood samples were treated with heparinase to ensure neutralization of possible residual heparin effect. The post-operative blood samples were spiked with buffer, rFVIIa (2 microg/mL), fibrinogen (1 mg/mL), or the combination of rFVIIa and fibrinogen. Despite neutralization of heparin, CPB surgery left a measurable coagulopathy that was thromboelastometrically characterized by prolonged onset of clotting, reduced maximum velocity of clot formation (MaxVel), and decreased maximum clot firmness (MCF). Ex vivo spiking of the postoperative samples with rFVIIa shortened the clotting time. Fibrinogen also shortened the clotting time and, in addition, improved the MaxVel, and MCF. Finally, adding the combination of rFVIIa and fibrinogen to the postoperative samples corrected all thromboelastometric parameters to the preoperative range. In conclusion, the correction of whole blood clotting abnormalities that occurs with rFVIIa and/or fibrinogen suggests that future clinical trials on treatment of bleeding during CPB surgery should study the haemostatic effect of fibrinogen or possibly the combination of rFVIIa and fibrinogen.
Roessler, Florian C; Teichert, Andrea; Ohlrich, Marcus; Marxsen, Jan H; Stellmacher, Florian; Tanislav, Christian; Seidel, Günter
2014-11-30
Agreement about the most suitable clot formation protocol for sonothrombolysis investigations is lacking. Lysis rates vary strongly owing to different test conditions and, thus, cannot be compared. We aim to establish a simple but physiologically grounded protocol for in vitro coagulation to enable standardized sonothrombolysis investigations. Clots were generated from platelet-rich plasma (PRP) obtained by centrifugation (10 min, 180 × g) of human venous blood (VB). PRP was mixed with the boundary layer formed between the supernatant and the erythrocyte layer. To achieve clots with different platelet counts, PRP was gradually substituted with platelet-free plasma (PFP), harvested from the supernatant of VB after centrifugation (10 min, 2570 × g). Clot types were examined for histological appearance, hydrodynamic resistance under physiological flows, and lysis rate measured by weight loss after a 2-h treatment with recombinant tissue plasminogen activator (rt-PA) (60 kU/ml). Lysis rates of the most suitable clot were measured after a 1-h treatment with rt-PA (60 kU/ml), and combined treatment with rt-PA and 2-MHz transcranial color-coded sonography (TCCS) (0.179 W/cm(2)) or 2-MHz transcranial Doppler (TCD) (0.457 W/cm(2)). With increased platelet count, the hydrodynamic resistance of the artificial clots increased, their histological appearance became more physiological, and lysis rates decreased. The most suitable clots consisted of 1.5-ml PRP, 2.0-ml PFP, and 0.5-ml boundary layer. Their lysis rates were 36.7 ± 7.8% (rt-PA), 40.8 ± 8.6% (rt-PA+TCCS), and 40.4 ± 8.3% (rt-PA+TCD). These systemic investigations were conducted for the first time. This protocol should be used for standardized sonothrombolysis investigations. Copyright © 2014 Elsevier B.V. All rights reserved.
Degeneracy of gravitational waveforms in the context of GW150914
NASA Astrophysics Data System (ADS)
Creswell, James; Liu, Hao; Jackson, Andrew D.; von Hausegger, Sebastian; Naselsky, Pavel
2018-03-01
We study the degeneracy of theoretical gravitational waveforms for binary black hole mergers using an aligned-spin effective-one-body model. After appropriate truncation, bandpassing, and matching, we identify regions in the mass–spin parameter space containing waveforms similar to the template proposed for GW150914, with masses m1 = 36+5‑4 Msolar and m2 = 29+4‑4 Msolar, using the cross-correlation coefficient as a measure of the similarity between waveforms. Remarkably high cross-correlations are found across broad regions of parameter space. The associated uncertanties exceed these from LIGO's Bayesian analysis considerably. We have shown that waveforms with greatly increased masses, such as m1 = 70 Msolar and m2 = 35 Msolar, and strong anti-aligned spins (χ1 = 0.95 and χ2 = ‑0.95) yield almost the same signal-to-noise ratio in the strain data for GW150914.
NASA Astrophysics Data System (ADS)
Minamikawa, Y.; Sato, H.; Mori, F.; Damayanthi, R. M. T.; Takahashi, H.; Ohno, M.
2008-04-01
We are developing a new x-ray microcalorimeter based on a superconducting transition edge sensor (TES) as an imaging sensor. Our measurement shows unique waveforms which we consider as an expression of thermal nonuniformity of TES films. This arises from the different thermal responses, so that response signal shapes would vary according to the position of the incident x-ray. This position dependency deteriorate the measured energy resolution, but with appropriate waveform analysis, this would be useful for imaging device. For more inspection, we have developed a simulation code which enables a dynamic simulation to obtain a transient response of the TES by finite differential method. Temperature and electric current distributions are calculated. As a result, we successfully obtained waveform signals. The calculated signal waveforms have similar characteristics to the measured signals. This simulation visualized the transition state of the device and will help to design better detector.
NASA Astrophysics Data System (ADS)
Zhu, Hui; Shan, Xuekang; Sun, Xiaohan
2017-10-01
A method for reconstructing the vibration waveform from the optical time-domain backscattering pulses in the distributed optical fiber sensing system (DOFSS) is proposed, which allows for extracting and recovering the external vibration signal from the tested pulses by analog signal processing, so that can obtain vibration location and waveform simultaneously. We establish the response model of DOFSS to the external vibration and analyze the effects of system parameters on the operational performance. The main parts of the DOFSS are optimized, including delay fiber length and wavelength, to improve the sensitivity of the system. The experimental system is set up and the vibration amplitudes and reconstructed waveforms are fit well with the original driving signal. The experimental results demonstrate that the performance of vibration waveform reconstruction is good with SNR of 15 dB whenever the external vibrations with different intensities and frequencies exert on the sensing fiber.
Determination of tumor cell procoagulant activity by Sonoclot analysis in whole blood.
Amirkhosravi, A; Biggerstaff, J P; Warnes, G; Francis, D A; Francis, J L
1996-12-01
Coagulation activation in cancer may be due to expression of procoagulant activity (PCA) by tumor cells. Some PCA activate coagulation, while others influence platelet aggregation. Thus, clotting time assessments of PCA may not reflect the potential for hypercoagulability. We therefore studied the effect of various malignant and non-malignant cells on whole blood coagulation using the Sonoclot Analyzer. Five human (HT29 colon, J82 bladder, MCF-7 breast, BT-474 breast and A375 malignant melanoma) and three rodent (MC28, WEHI-164 and Neuro2a) cell lines were used. Rat thymocytes and peritoneal macrophages and human endotoxin-stimulated mononuclear cells and umbilical vein endothelial cells (HUVEC) were used as non-malignant controls. All tumor cells markedly shortened the recalcification time of citrated blood and the most potent (HT29 and J82) also increased clot rate (P < 0.01). The breast cancer cells MCF-7 and BT-474 expressed only weak PCA and did not affect clotting rate. None of the non-malignant cells significantly affected clotting time or rate in whole blood. J82 and HT29 cells grown in serum-rich media shortened the recalcification time of both normal and FVII-deficient plasmas. However, cells grown in serum-free conditions had significantly less PCA in FVII-deficient plasma. We conclude that the Sonoclot Analyzer is useful for determining cellular PCA; significant PCA is a feature of malignant cells and cells grown in medium containing serum supplements cannot be reliably evaluated for PCA.
Singh, Kunwar Awaneesh; Nayak, Manasa K; Jagannadham, Medicherla V; Dash, Debabrata
2011-08-15
Several anticoagulants, anti-platelet and thrombolytic medications are used for the treatment of thrombotic disorders. Anti-coagulants and anti-platelet agents prevent the formation of blood clots but do not dissolve existing clots, whereas thrombolytic agents are able to dissolve a clot but emboli can form even after successful treatment. Thus, none of them provide a permanent and complete solution. In this regard a single molecule that could both dissolve the clot and prevent the formation of new clots would be useful in the treatment of thrombotic diseases. Crinumin, a stable and active (in many adverse conditions) serine protease, shows plasmin-like fibrinolytic activity and inhibits platelet aggregation and P-selectin exposure, as established by photography, phase contrast microscopy, whole blood optical Lumi-aggregometry and flow cytometry. Crinumin could be an efficient and inexpensive therapeutic agent for the treatment and prevention of thromboembolic diseases. Copyright © 2011 Elsevier Inc. All rights reserved.
Oldenburg, Amy L; Wu, Gongting; Spivak, Dmitry; Tsui, Frank; Wolberg, Alisa S; Fischer, Thomas H
2011-07-21
Improved methods for imaging and assessment of vascular defects are needed for directing treatment of cardiovascular pathologies. In this paper, we employ magnetomotive optical coherence tomography (MMOCT) as a platform both to detect and to measure the elasticity of blood clots. Detection is enabled through the use of rehydrated, lyophilized platelets loaded with superparamagnetic iron oxides (SPIO-RL platelets) that are functional infusion agents that adhere to sites of vascular endothelial damage. Evidence suggests that the sensitivity for detection is improved over threefold by magnetic interactions between SPIOs inside RL platelets. Using the same MMOCT system, we show how elastometry of simulated clots, using resonant acoustic spectroscopy, is correlated with the fibrin content of the clot. Both methods are based upon magnetic actuation and phase-sensitive optical monitoring of nanoscale displacements using MMOCT, underscoring its utility as a broad-based platform to detect and measure the molecular structure and composition of blood clots.
Nabiullina, R M; Mustafin, I G; Ataullakhanov, F I; Litvinov, R I; Zubairova, L D
2015-07-01
The effects of blood microparticles (MPs) on the dynamics of fibrin polymerization, clot structure and susceptibility to fibrinolysis were studied. Kinetics of fibrin polymerization, fibrinolysis, thrombin generation in platelet-free, microparticle-depleted and microparticle-depleted plasma replenished with cephalin, from healthy donors were analyzed in parallel. MPs have profound effects on all stages of fibrin formation, decrease its turbidity. All parameters obtained in the absence of MPs were recovered after reconstitution of phospholipids. Thrombin generation rates were reduced in the absence of MPs. In the presence of MPs the fibrin networks had less poro us structures with thinner fibers, while clots formed in the absence of MPs had larger pores and were built of thicker fibers. Clots formed in the presence of MPs were significantly more resistant to fibrinolysis. Results show that normally circulating MPs can support the formation of stable clots at the sites of vascular injury.
Single-platelet nanomechanics measured by high-throughput cytometry
NASA Astrophysics Data System (ADS)
Myers, David R.; Qiu, Yongzhi; Fay, Meredith E.; Tennenbaum, Michael; Chester, Daniel; Cuadrado, Jonas; Sakurai, Yumiko; Baek, Jong; Tran, Reginald; Ciciliano, Jordan C.; Ahn, Byungwook; Mannino, Robert G.; Bunting, Silvia T.; Bennett, Carolyn; Briones, Michael; Fernandez-Nieves, Alberto; Smith, Michael L.; Brown, Ashley C.; Sulchek, Todd; Lam, Wilbur A.
2017-02-01
Haemostasis occurs at sites of vascular injury, where flowing blood forms a clot, a dynamic and heterogeneous fibrin-based biomaterial. Paramount in the clot's capability to stem haemorrhage are its changing mechanical properties, the major drivers of which are the contractile forces exerted by platelets against the fibrin scaffold. However, how platelets transduce microenvironmental cues to mediate contraction and alter clot mechanics is unknown. This is clinically relevant, as overly softened and stiffened clots are associated with bleeding and thrombotic disorders. Here, we report a high-throughput hydrogel-based platelet-contraction cytometer that quantifies single-platelet contraction forces in different clot microenvironments. We also show that platelets, via the Rho/ROCK pathway, synergistically couple mechanical and biochemical inputs to mediate contraction. Moreover, highly contractile platelet subpopulations present in healthy controls are conspicuously absent in a subset of patients with undiagnosed bleeding disorders, and therefore may function as a clinical diagnostic biophysical biomarker.
Olarte, J L; Glover, M L; Totapally, B R
2001-01-01
We present a case of the use of alteplase for the lysis of a large urinary bladder clot. A neonate presented with respiratory failure, secondary to a left diaphragmatic hernia necessitating the need for extracorporeal membrane oxygenation (ECMO) support. On day 3 of ECMO support, hematuria was noted, and a subsequent urinary bladder ultrasound revealed a significant urinary bladder clot. Alteplase (0.5-1 mg) was instilled into the urinary bladder via a 10 French Foley catheter (Sherwood Medical, St. Louis, MO). The catheter was clamped for 1 hour, followed by irrigation with normal saline. Multiple doses of alteplase were administered, resulting in complete resolution of the bladder clot. No adverse effects were attributed to the use of the intravesical alteplase. Alteplase seems to be safe and effective for the resolution of bladder clots, thereby potentially avoiding more invasive surgical procedures.
Andrião-Escarso, S H; Sampaio, S V; Cunha, O A; Marangoni, S; Oliveira, B; Giglio, J R
1997-07-01
A detailed procedure for the isolation of a new clotting enzyme from the venom of Bothrops jararacussu (common name jararacuçu) is described. The estimated mol. wt of the native protein was 30,100 but 37,500 after reduction by dithiothreitol. Two major close bands corresponding to pI 5.18 and 5.20 were detected by electrofocusing but, after methanolysis, a single band focused at pI 8.20. The mol. wt of the protein moiety of this glycoprotein was 28,500, showing V-V-G-A-D-N-C-N-F-N... as N-terminal sequence. The content of neutral sugar was 4.8% and that of total sugars 5.3%. This clotting factor degraded only the A alpha-chain of the fibrinogen molecule. The stability of the clot, when produced in the presence of aprotinin opens new uses for snake clotting enzymes in the production of fibrin glue.
Wang, Wei; Ackland, David C; McClelland, Jodie A; Webster, Kate E; Halgamuge, Saman
2018-01-01
Quantitative gait analysis is an important tool in objective assessment and management of total knee arthroplasty (TKA) patients. Studies evaluating gait patterns in TKA patients have tended to focus on discrete data such as spatiotemporal information, joint range of motion and peak values of kinematics and kinetics, or consider selected principal components of gait waveforms for analysis. These strategies may not have the capacity to capture small variations in gait patterns associated with each joint across an entire gait cycle, and may ultimately limit the accuracy of gait classification. The aim of this study was to develop an automatic feature extraction method to analyse patterns from high-dimensional autocorrelated gait waveforms. A general linear feature extraction framework was proposed and a hierarchical partial least squares method derived for discriminant analysis of multiple gait waveforms. The effectiveness of this strategy was verified using a dataset of joint angle and ground reaction force waveforms from 43 patients after TKA surgery and 31 healthy control subjects. Compared with principal component analysis and partial least squares methods, the hierarchical partial least squares method achieved generally better classification performance on all possible combinations of waveforms, with the highest classification accuracy . The novel hierarchical partial least squares method proposed is capable of capturing virtually all significant differences between TKA patients and the controls, and provides new insights into data visualization. The proposed framework presents a foundation for more rigorous classification of gait, and may ultimately be used to evaluate the effects of interventions such as surgery and rehabilitation.
NASA Astrophysics Data System (ADS)
Chander, Shard; Ganguly, Debojyoti
2017-01-01
Water level was estimated, using AltiKa radar altimeter onboard the SARAL satellite, over the Ukai reservoir using modified algorithms specifically for inland water bodies. The methodology was based on waveform classification, waveform retracking, and dedicated inland range corrections algorithms. The 40-Hz waveforms were classified based on linear discriminant analysis and Bayesian classifier. Waveforms were retracked using Brown, Ice-2, threshold, and offset center of gravity methods. Retracking algorithms were implemented on full waveform and subwaveforms (only one leading edge) for estimating the improvement in the retrieved range. European Centre for Medium-Range Weather Forecasts (ECMWF) operational, ECMWF re-analysis pressure fields, and global ionosphere maps were used to exactly estimate the range corrections. The microwave and optical images were used for estimating the extent of the water body and altimeter track location. Four global positioning system (GPS) field trips were conducted on same day as the SARAL pass using two dual frequency GPS. One GPS was mounted close to the dam in static mode and the other was used on a moving vehicle within the reservoir in Kinematic mode. In situ gauge dataset was provided by the Ukai dam authority for the time period January 1972 to March 2015. The altimeter retrieved water level results were then validated with the GPS survey and in situ gauge dataset. With good selection of virtual station (waveform classification, back scattering coefficient), Ice-2 retracker and subwaveform retracker both work better with an overall root-mean-square error <15 cm. The results support that the AltiKa dataset, due to a smaller foot-print and sharp trailing edge of the Ka-band waveform, can be utilized for more accurate water level information over inland water bodies.
Cervantes, Felix A; Backus, Elaine A; Godfrey, Larry; Wallis, Christopher; Akbar, Waseem; Clark, Thomas L; Rojas, Maria G
2017-10-01
Probing behavior of Lygus lineolaris (Palisot de Beauvois) has previously been characterized with electropenetrography (EPG). Cell rupturing (CR) and ingestion (I) EPG waveforms were identified as the two main stylet-probing behaviors by adult L. lineolaris. However, characterization and identification of EPG waveforms are not complete until specific events of a particular waveform are correlated to insect probing. With the use of EPG, histology, microscopy, and chemical analysis, probing behavior of L. lineolaris on pin-head cotton squares was studied. Occurrences of waveforms CR and I were artificially terminated during the EPG recording. Histological samples of probed cotton squares were prepared and analyzed to correlate specific types and occurrences of feeding damage location and plant responses to insect feeding. Both CR and I occurred in the staminal column of the cotton square. Cell rupturing events elicited the production of dark-red deposits seen in histological staining that were demonstrated via chemical analysis to contain condensed tannins. We hypothesize that wounding and saliva secreted during CR triggered release of tannins, because tannin production was positively correlated with the number of probes with single CR events performed by L. lineolaris. Degraded plant tissue and tannins were removed from the staminal column during occurrence of waveform I. These results conclude the process of defining CR and I as probing waveforms performed by L. lineolaris on pin-head cotton squares. These biological definitions will now allow EPG to be used to quantitatively compare L. lineolaris feeding among different plant treatments, with the goal of improving pest management tactics against this pest. Published by Oxford University Press on behalf of Entomological Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.
Effect of low frequency ultrasound on combined rt-PA and eptifibatide thrombolysis in human clots.
Meunier, Jason M; Holland, Christy K; Pancioli, Arthur M; Lindsell, Christopher J; Shaw, George J
2009-01-01
Fibrinolytics such as recombinant tissue plasminogen activator (rt-PA) are used to treat thrombotic disease such as acute myocardial infarction (AMI) and ischemic stroke. Interest in increasing efficacy and reducing side effects has led to the study of adjuncts such as GP IIb-IIIa inhibitors and ultrasound (US) enhanced thrombolysis. Currently, GP IIb-IIIa inhibitor and fibrinolytic treatment are often used in AMI, and are under investigation for stroke treatment. However, little is known of the efficacy of combined GP IIb-IIIa inhibitor, fibrinolytic and ultrasound treatment. We measure the lytic efficacy of rt-PA, eptifibatide (Epf) and 120 kHz ultrasound treatment in an in-vitro human clot model. Blood was drawn from 15 subjects after IRB approval. Clots were made in 20 microL pipettes, and placed in a water tank for microscopic visualization during lytic treatment. Clots were exposed to control, rt-PA (rt-PA), eptifibatide (Epf), or rt-PA+eptifibatide (rt-PA + Epf), with (+US) or without (-US) ultrasound for 30 minutes at 37 degrees C in human plasma. Clot lysis was measured over time, using a microscopic imaging technique. The fractional clot loss (FCL) and initial lytic rate (LR) were used to quantify lytic efficacy. LR values for (- US) treated clots were 0.8+/-0.1(control), 1.8+/-0.3 (Epf), 1.5+/-0.2 (rt-PA), and 1.3+/-0.4 (rt-PA + Epf) (% clot width/minute) respectively. In comparison, the (+ US) group exhibited LR values of 1.6+/-0.2 (control), 4.3+/-0.4 (Epf), 6.3+/-0.4 (rt-PA), and 4.6+/-0.6 (rt-PA + Epf). For (- US) treated clots, FCL was 6.0+/-0.8 (control), 9.2+/-2.5 (Epf), 15.6+/-1.7 (rt-PA), and 28.0+/-2.2% (rt-PA + Epf) respectively. FCL for (+ US) clots was 13.5+/-2.4 (control), 20.7+/-6.4 (Epf), 44.4+/-3.6 (rt-PA) and 30.3+/-3.6% (rt-PA + Epf) respectively. Although the addition of eptifibatide enhances the in-vitro lytic efficacy of rt-PA in the absence of ultrasound, the efficacy of ultrasound and rt-PA is greater than that of combined ultrasound, rt-PA and eptifibatide exposure.
Effect of Low Frequency Ultrasound on Combined rt-PA and Eptifibatide Thrombolysis in Human Clots
Meunier, Jason M.; Holland, Christy K.; Pancioli, Arthur M.; Lindsell, Christopher J.; Shaw, George J.
2009-01-01
Introduction Fibrinolytics such as recombinant tissue plasminogen activator (rt-PA) are used to treat thrombotic disease such as acute myocardial infarction (AMI) and ischemic stroke. Interest in increasing efficacy and reducing side effects has led to the study of adjuncts such as GP IIb-IIIa inhibitors and ultrasound (US) enhanced thrombolysis. Currently, GP IIb-IIIa inhibitor and fibrinolytic treatment are often used in AMI, and are under investigation for stroke treatment. However, little is known of the efficacy of combined GP IIb-IIIa inhibitor, fibrinolytic and ultrasound treatment. We measure the lytic efficacy of rt-PA, eptifibatide (Epf) and 120 kHz ultrasound treatment in an in-vitro human clot model. Materials and Methods Blood was drawn from 15 subjects after IRB approval. Clots were made in 20 μL pipettes, and placed in a water tank for microscopic visualization during lytic treatment. Clots were exposed to control, rt-PA (rt-PA), eptifibatide (Epf), or rt-PA+eptifibatide (rt-PA+Epf), with or without ultrasound for 30 minutes at 37°C in human plasma. Clot lysis was measured over time, using a microscopic imaging technique. The fractional clot loss (FCL) and initial lytic rate (LR) were used to quantify lytic efficacy. Results and Conclusions LR values for (−US) treated clots were 0.8±0.1(control), 1.8±0.3 (Epf), 1.5±0.2 (rt-PA), and 1.3±0.4 (rt-PA+Epf) (% clot width/minute) respectively. In comparison, the (+US) group exhibited LR values of 1.6±0.2 (control), 4.3±0.4 (Epf), 6.3±0.4 (rt-PA), and 4.6±0.6 (rt-PA+Epf). For (−US) treated clots, FCL was 6.0±0.8 (control), 9.2±2.5 (Epf), 15.6±1.7 (rt-PA), and 28.0±2.2% (rt-PA+Epf) respectively. FCL for (+US) clots was 13.5±2.4 (control), 20.7±6.4 (Epf), 44.4±3.6 (rt-PA) and 30.3±3.6% (rt-PA+Epf) respectively. Although the addition of eptifibatide enhances the in-vitro lytic efficacy of rt-PA in the absence of ultrasound, the efficacy of ultrasound and rt-PA is greater than that of combined ultrasound, rt-PA and eptifibatide exposure. PMID:18619651
The Waveform Suite: A robust platform for accessing and manipulating seismic waveforms in MATLAB
NASA Astrophysics Data System (ADS)
Reyes, C. G.; West, M. E.; McNutt, S. R.
2009-12-01
The Waveform Suite, developed at the University of Alaska Geophysical Institute, is an open-source collection of MATLAB classes that provide a means to import, manipulate, display, and share waveform data while ensuring integrity of the data and stability for programs that incorporate them. Data may be imported from a variety of sources, such as Antelope, Winston databases, SAC files, SEISAN, .mat files, or other user-defined file formats. The waveforms being manipulated in MATLAB are isolated from their stored representations, relieving the overlying programs from the responsibility of understanding the specific format in which data is stored or retrieved. The waveform class provides an object oriented framework that simplifies manipulations to waveform data. Playing with data becomes easier because the tedious aspects of data manipulation have been automated. The user is able to change multiple waveforms simultaneously using standard mathematical operators and other syntactically familiar functions. Unlike MATLAB structs or workspace variables, the data stored within waveform class objects are protected from modification, and instead are accessed through standardized functions, such as get and set; these are already familiar to users of MATLAB’s graphical features. This prevents accidental or nonsensical modifications to the data, which in turn simplifies troubleshooting of complex programs. Upgrades to the internal structure of the waveform class are invisible to applications which use it, making maintenance easier. We demonstrate the Waveform Suite’s capabilities on seismic data from Okmok and Redoubt volcanoes. Years of data from Okmok were retrieved from Antelope and Winston databases. Using the Waveform Suite, we built a tremor-location program. Because the program was built on the Waveform Suite, modifying it to operate on real-time data from Redoubt involved only minimal code changes. The utility of the Waveform Suite as a foundation for large developments is demonstrated with the Correlation Toolbox for MATLAB. This mature package contains 50+ codes for carrying out various type of waveform correlation analyses (multiplet analysis, clustering, interferometry, …) This package is greatly strengthened by delegating numerous book-keeping and signal processing tasks to the underlying Waveform Suite. The Waveform Suite’s built-in tools for searching arbitrary directory/file structures is demonstrated with matched video and audio from the recent eruption of Redoubt Volcano. These tools were used to find subsets of photo images corresponding to specific seismic traces. Using Waveform’s audio file routines, matched video and audio were assembled to produce outreach-quality eruption products. The Waveform Suite is not designed as a ready-to-go replacement for more comprehensive packages such as SAC or AH. Rather, it is a suite of classes which provide core time series functionality in a MATLAB environment. It is designed to be a more robust alternative to the numerous ad hoc MATLAB formats that exist. Complex programs may be created upon the Waveform Suite’s framework, while existing programs may be modified to take advantage of the Waveform Suites capabilities.
The effects of QuikClot Combat Gauze on hemorrhage control in the presence of hemodilution.
Johnson, Don; Agee, Samantha; Reed, Amanda; Gegel, Brian; Burgert, James; Gasko, John; Loughren, Michael
2012-01-01
Although hemostatic agents may be effective at stopping hemorrhage, they may fail because of hemodilution from intravenous fluids. The purpose of this study was to investigate the effects of QuikClot Combat Gauze (QCG) on rebleeding in a class II hemorrhage in the presence of hemodilution in a lethal femoral injury. This was a prospective experimental, between swine subjects design. Pigs were assigned to one of two groups: QCG (n=15) or control (n=15). Thirty percent of the pig's blood was exsanguinated and then a 3:1 ratio of ringers lactate was administered. A groin injury was created by transecting the femoral artery and vein to simulate a battlefield injury and allowed to bleed for one minute. After one minute of hemorrhage, proximal pressure was applied to the injury, and QCG was placed into the wound followed by standard wound packing. The control group underwent the same procedures with the exception of the hemostatic agent. For both groups, 5 minutes of direct pressure was applied to the wound followed by a standard pressure dressing. Dressings were removed after 30 minutes, and the amount of hemorrhage was calculated in milliliters for each group for a period of 5 minutes. An activated clotting time was used to exclude any pigs with coagulation pathology. A multivariate analysis of variance indicated that there were no significant differences in the groups relative to weight, amount of one minute hemorrhage, fluid deficit replacement, blood volume, and the activated clotting time (P>.05) indicating that the groups were equivalent on these parameters. A t test indicated that there was significantly less bleeding (P=.002) in the QCG group (36 mL±112 mL) compared to the control group (340 mL±297 ml). QCG produces a robust clot that can more effectively tolerate hemodilution compared to a control group.
Improving Free-Piston Stirling Engine Specific Power
NASA Technical Reports Server (NTRS)
Briggs, Maxwell Henry
2014-01-01
This work uses analytical methods to demonstrate the potential benefits of optimizing piston and/or displacer motion in a Stirling Engine. Isothermal analysis was used to show the potential benefits of ideal motion in ideal Stirling engines. Nodal analysis is used to show that ideal piston and displacer waveforms are not optimal in real Stirling engines. Constrained optimization was used to identify piston and displacer waveforms that increase Stirling engine specific power.
Improving Free-Piston Stirling Engine Specific Power
NASA Technical Reports Server (NTRS)
Briggs, Maxwell H.
2015-01-01
This work uses analytical methods to demonstrate the potential benefits of optimizing piston and/or displacer motion in a Stirling engine. Isothermal analysis was used to show the potential benefits of ideal motion in ideal Stirling engines. Nodal analysis is used to show that ideal piston and displacer waveforms are not optimal in real Stirling engines. Constrained optimization was used to identify piston and displacer waveforms that increase Stirling engine specific power.
Global and local waveform simulations using the VERCE platform
NASA Astrophysics Data System (ADS)
Garth, Thomas; Saleh, Rafiq; Spinuso, Alessandro; Gemund, Andre; Casarotti, Emanuele; Magnoni, Federica; Krischner, Lion; Igel, Heiner; Schlichtweg, Horst; Frank, Anton; Michelini, Alberto; Vilotte, Jean-Pierre; Rietbrock, Andreas
2017-04-01
In recent years the potential to increase resolution of seismic imaging by full waveform inversion has been demonstrated on a range of scales from basin to continental scales. These techniques rely on harnessing the computational power of large supercomputers, and running large parallel codes to simulate the seismic wave field in a three-dimensional geological setting. The VERCE platform is designed to make these full waveform techniques accessible to a far wider spectrum of the seismological community. The platform supports the two widely used spectral element simulation programs SPECFEM3D Cartesian, and SPECFEM3D globe, allowing users to run a wide range of simulations. In the SPECFEM3D Cartesian implementation the user can run waveform simulations on a range of pre-loaded meshes and velocity models for specific areas, or upload their own velocity model and mesh. In the new SPECFEM3D globe implementation, the user will be able to select from a number of continent scale model regions, or perform waveform simulations for the whole earth. Earthquake focal mechanisms can be downloaded within the platform, for example from the GCMT catalogue, or users can upload their own focal mechanism catalogue through the platform. The simulations can be run on a range of European supercomputers in the PRACE network. Once a job has been submitted and run through the platform, the simulated waveforms can be manipulated or downloaded for further analysis. The misfit between the simulated and recorded waveforms can then be calculated through the platform through three interoperable workflows, for raw-data access (FDSN) and caching, pre-processing and finally misfit. The last workflow makes use of the Pyflex analysis software. In addition, the VERCE platform can be used to produce animations of waveform propagation through the velocity model, and synthetic shakemaps. All these data-products are made discoverable and re-usable thanks to the VERCE data and metadata management layer. We demonstrate the functionality of the VERCE platform with two use cases, one using the pre-loaded velocity model and mesh for the Maule area of Chile using the SPECFEM3D Cartesian workflow, and one showing the output of a global simulation using the SPECFEM3D globe workflow. It is envisioned that this tool will allow a much greater range of seismologists to access these full waveform inversion tools, and aid full waveform tomographic and source inversion, synthetic shakemap production and other full waveform applications, in a wide range of tectonic settings.
Platelet Counts in Insoluble Platelet-Rich Fibrin Clots: A Direct Method for Accurate Determination.
Kitamura, Yutaka; Watanabe, Taisuke; Nakamura, Masayuki; Isobe, Kazushige; Kawabata, Hideo; Uematsu, Kohya; Okuda, Kazuhiro; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki
2018-01-01
Platelet-rich fibrin (PRF) clots have been used in regenerative dentistry most often, with the assumption that growth factor levels are concentrated in proportion to the platelet concentration. Platelet counts in PRF are generally determined indirectly by platelet counting in other liquid fractions. This study shows a method for direct estimation of platelet counts in PRF. To validate this method by determination of the recovery rate, whole-blood samples were obtained with an anticoagulant from healthy donors, and platelet-rich plasma (PRP) fractions were clotted with CaCl 2 by centrifugation and digested with tissue-plasminogen activator. Platelet counts were estimated before clotting and after digestion using an automatic hemocytometer. The method was then tested on PRF clots. The quality of platelets was examined by scanning electron microscopy and flow cytometry. In PRP-derived fibrin matrices, the recovery rate of platelets and white blood cells was 91.6 and 74.6%, respectively, after 24 h of digestion. In PRF clots associated with small and large red thrombi, platelet counts were 92.6 and 67.2% of the respective total platelet counts. These findings suggest that our direct method is sufficient for estimating the number of platelets trapped in an insoluble fibrin matrix and for determining that platelets are distributed in PRF clots and red thrombi roughly in proportion to their individual volumes. Therefore, we propose this direct digestion method for more accurate estimation of platelet counts in most types of platelet-enriched fibrin matrix.
Platelet Counts in Insoluble Platelet-Rich Fibrin Clots: A Direct Method for Accurate Determination
Kitamura, Yutaka; Watanabe, Taisuke; Nakamura, Masayuki; Isobe, Kazushige; Kawabata, Hideo; Uematsu, Kohya; Okuda, Kazuhiro; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki
2018-01-01
Platelet-rich fibrin (PRF) clots have been used in regenerative dentistry most often, with the assumption that growth factor levels are concentrated in proportion to the platelet concentration. Platelet counts in PRF are generally determined indirectly by platelet counting in other liquid fractions. This study shows a method for direct estimation of platelet counts in PRF. To validate this method by determination of the recovery rate, whole-blood samples were obtained with an anticoagulant from healthy donors, and platelet-rich plasma (PRP) fractions were clotted with CaCl2 by centrifugation and digested with tissue-plasminogen activator. Platelet counts were estimated before clotting and after digestion using an automatic hemocytometer. The method was then tested on PRF clots. The quality of platelets was examined by scanning electron microscopy and flow cytometry. In PRP-derived fibrin matrices, the recovery rate of platelets and white blood cells was 91.6 and 74.6%, respectively, after 24 h of digestion. In PRF clots associated with small and large red thrombi, platelet counts were 92.6 and 67.2% of the respective total platelet counts. These findings suggest that our direct method is sufficient for estimating the number of platelets trapped in an insoluble fibrin matrix and for determining that platelets are distributed in PRF clots and red thrombi roughly in proportion to their individual volumes. Therefore, we propose this direct digestion method for more accurate estimation of platelet counts in most types of platelet-enriched fibrin matrix. PMID:29450197
Acconcia, Christopher; Leung, Ben Y C; Manjunath, Anoop; Goertz, David E
2015-10-01
In previous work, we examined microscale interactions between microbubbles and fibrin clots under exposure to 1 ms ultrasound pulses. This provided direct evidence that microbubbles were capable of deforming clot boundaries and penetrating into clots, while also affecting fluid uptake and inducing fibrin network damage. Here, we investigate the effect of short duration (15 μs) pulses on microscale bubble-clot interactions as function of bubble diameter (3-9 μm) and pressure. Individual microbubbles (n = 45) were placed at the clot boundary with optical tweezers and exposed to 1 MHz ultrasound. High-speed (10 kfps) imaging and 2-photon microscopy were performed during and after exposure, respectively. While broadly similar phenomena were observed as in the 1 ms pulse case (i.e., bubble penetration, network damage and fluid uptake), substantial quantitative differences were present. The pressure threshold for bubble penetration was increased from 0.39 MPa to 0.6 MPa, and those bubbles that did enter clots had reduced penetration depths and were associated with less fibrin network damage and nanobead uptake. This appeared to be due in large part to increased bubble shrinkage relative to the 1 ms pulse case. Stroboscopic imaging was performed on a subset of bubbles (n = 11) and indicated that complex bubble oscillations can occur during this process. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Use of fibrin sealants for the localized, controlled release of cefazolin
Tredwell, Stephen; Jackson, John K.; Hamilton, Donald; Lee, Vivian; Burt, Helen M.
2006-01-01
Background Fibrin sealants are used increasingly in surgery to reduce bleeding and improve wound healing. They have great potential as biocompatible, biodegradable drug delivery systems, because the sealant may adhere to the target tissue and allow controlled release of the drug over an extended period. We investigated the encapsulation, stability and controlled release of erythromycin and cefazolin from Beriplast fibrin sealants (Aventis Behring Canada). Methods Drug-loaded clots were cast in glass vials and allowed to set. We observed the clots for drug precipitation and aggregation, and we assessed the effect of drug encapsulation on clot strength. Drug stability and release from the clots in phosphate buffered saline (PBS) was quantified by ultraviolet and visible violet absorbance spectroscopy and high-performance liquid chromatography. Results Erythromycin was found to release slowly from the fibrin clots over the first 2 hours but then degrade rapidly. Cefazolin was found to be very stable in clots in PBS (97% stable at 2 d and 93% stable at 5 d). The drug released in a controlled manner over 2 days, with most being released during the first day. The dose of drug released could be varied by changing the amount placed in the thrombin solution. Clot thickness had no effect on the rate of cefazolin release. Conclusion Overall, the 2-day release profile and the excellent stability of the drug suggest that cefazolin-loaded fibrin sealants may offer an effective route of postoperative antibiotic delivery. PMID:17152573
Insights into abnormal hemostasis in the Quebec platelet disorder from analyses of clot lysis.
Diamandis, M; Adam, F; Kahr, W H A; Wang, P; Chorneyko, K A; Arsenault, A L; Rivard, G E; Hayward, C P M
2006-05-01
The Quebec platelet disorder (QPD) is inherited and characterized by delayed-onset bleeding following hemostatic challenge. Other characteristics include increased expression and storage of active urokinase-type plasminogen activator (u-PA) in platelets in the setting of normal to increased u-PA in plasma. There is also consumption of platelet plasminogen activator inhibitor-1 and increased generation of plasmin in platelets accompanied by proteolysis of stored alpha-granule proteins, including Factor V. Although fibrinolysis has been proposed to contribute to QPD bleeding, the effects of QPD blood and platelets on clot lysis have not been evaluated. We used thromboelastography (TEG), biochemical evaluations of whole blood clot lysis, assessments of clot ultrastructure, and perfusion of blood over preformed fibrin to gain insights into the disturbed hemostasis in the QPD. Thromboelastography was not sensitive to the increased u-PA in QPD blood. However, there was abnormal plasmin generation in QPD whole blood clots, generated at low shear, with biochemical evidence of increased fibrinolysis. The incorporation of QPD platelets into a forming clot led to progressive disruption of fibrin and platelet aggregates unless drugs were added to inhibit plasmin. In whole blood perfusion studies, QPD platelets showed normal adherence to fibrin, but their adhesion was followed by accelerated fibrinolysis. The QPD is associated with "gain-of-function" abnormalities that increase the lysis of forming or preformed clots. These findings suggest accelerated fibrinolysis is an important contributor to QPD bleeding.
Robust MOE Detector for DS-CDMA Systems with Signature Waveform Mismatch
NASA Astrophysics Data System (ADS)
Lin, Tsui-Tsai
In this letter, a decision-directed MOE detector with excellent robustness against signature waveform mismatch is proposed for DS-CDMA systems. Both the theoretic analysis and computer simulation results demonstrate that the proposed detector can provide better SINR performance than that of conventional detectors.
NASA Astrophysics Data System (ADS)
Ijaz, S.; Shahzadi, Iqra; Nadeem, S.; Saleem, Anber
2017-11-01
In this speculative analysis, our main focused is to address the neurotic condition that occurs due to accumulation of blood components on the wall of the artery that results in blood coagulation. Specifically, to perceive this phenomena clot model is considered. To discuss this analysis mathematical model is formed in the presence of the effective thermal conductivity and variable viscosity of base fluid. Appropriate slip conditions are employed to obtain the close form solutions of temperature and velocity profile. The graphical illustrations have been presented for the assessment of pressure rise, pressure gradient and velocity profile. The effects of several parameters on the flow quantities for theoretical observation are investigated. At the end, the results confirmed that the impulsion of copper and silver nanoparticles as drug agent enlarges the amplitude of the velocity and hence nanoparticles play an important role in engineering and biomedical applications such as drug delivery system.
Arnuntasupakul, Vanlapa; Van Zundert, Tom C R V; Vijitpavan, Amorn; Aliste, Julian; Engsusophon, Phatthanaphol; Leurcharusmee, Prangmalee; Ah-Kye, Sonia; Finlayson, Roderick J; Tran, De Q H
2016-01-01
Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for loss of resistance (LOR): when the needle tip is correctly positioned inside the epidural space, pressure measurement results in a pulsatile waveform. In this randomized trial, we compared conventional and EWA-confirmed LOR in 2 teaching centers. Our research hypothesis was that EWA-confirmed LOR would decrease the failure rate of thoracic epidural blocks. One hundred patients undergoing thoracic epidural blocks for thoracic surgery, abdominal surgery, or rib fractures were randomized to conventional LOR or EWA-LOR. The operator was allowed as many attempts as necessary to achieve a satisfactory LOR (by feel) in the conventional group. In the EWA-LOR group, LOR was confirmed by connecting the epidural needle to a pressure transducer using a rigid extension tubing. Positive waveforms indicated that the needle tip was positioned inside the epidural space. The operator was allowed a maximum of 3 different intervertebral levels to obtain a positive waveform. If waveforms were still absent at the third level, the operator simply accepted LOR as the technical end point. However, the patient was retained in the EWA-LOR group (intent-to-treat analysis).After achieving a satisfactory tactile LOR (conventional group), positive waveforms (EWA-LOR group), or a third intervertebral level with LOR but no waveform (EWA-LOR group), the operator administered a 4-mL test dose of lidocaine 2% with epinephrine 5 μg/mL. Fifteen minutes after the test dose, a blinded investigator assessed the patient for sensory block to ice. Compared with LOR, EWA-LOR resulted in a lower rate of primary failure (2% vs 24%; P = 0.002). Subgroup analysis based on experience level reveals that EWA-LOR outperformed conventional LOR for novice (P = 0.001) but not expert operators. The performance time was longer in the EWA-LOR group (11.2 ± 6.2 vs 8.0 ± 4.6 minutes; P = 0.006). Both groups were comparable in terms of operator's level of expertise, depth of the epidural space, approach, and LOR medium. In the EWA-LOR group, operators obtained a pulsatile waveform with the first level attempted in 60% of patients. However, 40% of subjects required performance at a second or third level. Compared with its conventional counterpart, EWA-confirmed LOR results in a lower failure rate for thoracic epidural blocks (2% vs 24%) in our teaching centers. Confirmatory EWA provides significant benefits for inexperienced operators.
Simulation Analysis of DC and Switching Impulse Superposition Circuit
NASA Astrophysics Data System (ADS)
Zhang, Chenmeng; Xie, Shijun; Zhang, Yu; Mao, Yuxiang
2018-03-01
Surge capacitors running between the natural bus and the ground are affected by DC and impulse superposition voltage during operation in the converter station. This paper analyses the simulation aging circuit of surge capacitors by PSCAD electromagnetic transient simulation software. This paper also analyses the effect of the DC voltage to the waveform of the impulse voltage generation. The effect of coupling capacitor to the test voltage waveform is also studied. Testing results prove that the DC voltage has little effect on the waveform of the output of the surge voltage generator, and the value of the coupling capacitor has little effect on the voltage waveform of the sample. Simulation results show that surge capacitor DC and impulse superimposed aging test is feasible.
A simple computer-based measurement and analysis system of pulmonary auscultation sounds.
Polat, Hüseyin; Güler, Inan
2004-12-01
Listening to various lung sounds has proven to be an important diagnostic tool for detecting and monitoring certain types of lung diseases. In this study a computer-based system has been designed for easy measurement and analysis of lung sound using the software package DasyLAB. The designed system presents the following features: it is able to digitally record the lung sounds which are captured with an electronic stethoscope plugged to a sound card on a portable computer, display the lung sound waveform for auscultation sites, record the lung sound into the ASCII format, acoustically reproduce the lung sound, edit and print the sound waveforms, display its time-expanded waveform, compute the Fast Fourier Transform (FFT), and display the power spectrum and spectrogram.
Aston, Philip J; Christie, Mark I; Huang, Ying H; Nandi, Manasi
2018-03-01
Advances in monitoring technology allow blood pressure waveforms to be collected at sampling frequencies of 250-1000 Hz for long time periods. However, much of the raw data are under-analysed. Heart rate variability (HRV) methods, in which beat-to-beat interval lengths are extracted and analysed, have been extensively studied. However, this approach discards the majority of the raw data. Our aim is to detect changes in the shape of the waveform in long streams of blood pressure data. Our approach involves extracting key features from large complex data sets by generating a reconstructed attractor in a three-dimensional phase space using delay coordinates from a window of the entire raw waveform data. The naturally occurring baseline variation is removed by projecting the attractor onto a plane from which new quantitative measures are obtained. The time window is moved through the data to give a collection of signals which relate to various aspects of the waveform shape. This approach enables visualisation and quantification of changes in the waveform shape and has been applied to blood pressure data collected from conscious unrestrained mice and to human blood pressure data. The interpretation of the attractor measures is aided by the analysis of simple artificial waveforms. We have developed and analysed a new method for analysing blood pressure data that uses all of the waveform data and hence can detect changes in the waveform shape that HRV methods cannot, which is confirmed with an example, and hence our method goes 'beyond HRV'.
Aston, Philip J; Christie, Mark I; Huang, Ying H; Nandi, Manasi
2018-01-01
Abstract Advances in monitoring technology allow blood pressure waveforms to be collected at sampling frequencies of 250–1000 Hz for long time periods. However, much of the raw data are under-analysed. Heart rate variability (HRV) methods, in which beat-to-beat interval lengths are extracted and analysed, have been extensively studied. However, this approach discards the majority of the raw data. Objective: Our aim is to detect changes in the shape of the waveform in long streams of blood pressure data. Approach: Our approach involves extracting key features from large complex data sets by generating a reconstructed attractor in a three-dimensional phase space using delay coordinates from a window of the entire raw waveform data. The naturally occurring baseline variation is removed by projecting the attractor onto a plane from which new quantitative measures are obtained. The time window is moved through the data to give a collection of signals which relate to various aspects of the waveform shape. Main results: This approach enables visualisation and quantification of changes in the waveform shape and has been applied to blood pressure data collected from conscious unrestrained mice and to human blood pressure data. The interpretation of the attractor measures is aided by the analysis of simple artificial waveforms. Significance: We have developed and analysed a new method for analysing blood pressure data that uses all of the waveform data and hence can detect changes in the waveform shape that HRV methods cannot, which is confirmed with an example, and hence our method goes ‘beyond HRV’. PMID:29350622
Efficiency Analysis of Waveform Shape for Electrical Excitation of Nerve Fibers
Wongsarnpigoon, Amorn; Woock, John P.; Grill, Warren M.
2011-01-01
Stimulation efficiency is an important consideration in the stimulation parameters of implantable neural stimulators. The objective of this study was to analyze the effects of waveform shape and duration on the charge, power, and energy efficiency of neural stimulation. Using a population model of mammalian axons and in vivo experiments on cat sciatic nerve, we analyzed the stimulation efficiency of four waveform shapes: square, rising exponential, decaying exponential, and rising ramp. No waveform was simultaneously energy-, charge-, and power-optimal, and differences in efficiency among waveform shapes varied with pulse width (PW) For short PWs (≤ 0.1 ms), square waveforms were no less energy-efficient than exponential waveforms, and the most charge-efficient shape was the ramp. For long PWs (≥0.5 ms), the square was the least energy-efficient and charge-efficient shape, but across most PWs, the square was the most power-efficient shape. Rising exponentials provided no practical gains in efficiency over the other shapes, and our results refute previous claims that the rising exponential is the energy-optimal shape. An improved understanding of how stimulation parameters affect stimulation efficiency will help improve the design and programming of implantable stimulators to minimize tissue damage and extend battery life. PMID:20388602
Numerical Simulation of Rheological, Chemical and Hydromechanical Processes of Thrombolysis
NASA Astrophysics Data System (ADS)
Khramchenkov, E.; Khramchenkov, M.
2015-04-01
Mathematical model of clot lysis in blood vessels is developed on the basis of equations of convection-diffusion. Fibrin of the clot is considered stationary solid phase, and plasminogen, plasmin and plasminogen-activators - as dissolved fluid phases. As a result of numerical solution of the model predictions of lysis process are gained. Important influence of clot swelling on the process of lysis is revealed.
Cloning and expression of clt genes encoding milk-clotting proteases from Myxococcus xanthus 422.
Poza, M; Prieto-Alcedo, M; Sieiro, C; Villa, T G
2004-10-01
The screening of a gene library of the milk-clotting strain Myxococcus xanthus 422 constructed in Escherichia coli allowed the description of eight positive clones containing 26 open reading frames. Only three of them (cltA, cltB, and cltC) encoded proteins that exhibited intracellular milk-clotting ability in E. coli, Saccharomyces cerevisiae, and Pichia pastoris expression systems.
Fealy, Nigel; Aitken, Leanne; du Toit, Eugene; Lo, Serigne; Baldwin, Ian
2017-10-01
To determine whether blood flow rate influences circuit life in continuous renal replacement therapy. Prospective randomized controlled trial. Single center tertiary level ICU. Critically ill adults requiring continuous renal replacement therapy. Patients were randomized to receive one of two blood flow rates: 150 or 250 mL/min. The primary outcome was circuit life measured in hours. Circuit and patient data were collected until each circuit clotted or was ceased electively for nonclotting reasons. Data for clotted circuits are presented as median (interquartile range) and compared using the Mann-Whitney U test. Survival probability for clotted circuits was compared using log-rank test. Circuit clotting data were analyzed for repeated events using hazards ratio. One hundred patients were randomized with 96 completing the study (150 mL/min, n = 49; 250 mL/min, n = 47) using 462 circuits (245 run at 150 mL/min and 217 run at 250 mL/min). Median circuit life for first circuit (clotted) was similar for both groups (150 mL/min: 9.1 hr [5.5-26 hr] vs 10 hr [4.2-17 hr]; p = 0.37). Continuous renal replacement therapy using blood flow rate set at 250 mL/min was not more likely to cause clotting compared with 150 mL/min (hazards ratio, 1.00 [0.60-1.69]; p = 0.68). Gender, body mass index, weight, vascular access type, length, site, and mode of continuous renal replacement therapy or international normalized ratio had no effect on clotting risk. Continuous renal replacement therapy without anticoagulation was more likely to cause clotting compared with use of heparin strategies (hazards ratio, 1.62; p = 0.003). Longer activated partial thromboplastin time (hazards ratio, 0.98; p = 0.002) and decreased platelet count (hazards ratio, 1.19; p = 0.03) were associated with a reduced likelihood of circuit clotting. There was no difference in circuit life whether using blood flow rates of 250 or 150 mL/min during continuous renal replacement therapy.
Panes, Olga; Padilla, Oslando; Matus, Valeria; Sáez, Claudia G; Berkovits, Alejandro; Pereira, Jaime; Mezzano, Diego
2012-01-01
Fibrinolysis dysfunctions cause bleeding or predisposition to thrombosis. Platelets contain several factors of the fibrinolytic system, which could up or down regulate this process. However, the temporal relationship and relative contributions of plasma and platelet components in clot lysis are mostly unknown. We developed a clot lysis time (CLT) assay in platelet-rich plasma (PRP-CLT, with and without stimulation) and compared it to a similar one in platelet-free plasma (PFP) and to another previously reported test in platelet-poor plasma (PPP). We also studied the differential effects of a single dose of tranexamic acid (TXA) on these tests in healthy subjects. PFP- and PPP-CLT were significantly shorter than PRP-CLT, and the three assays were highly correlated (p < 0.0001). PFP- and PPP-, but more significantly PRP-CLT, were positively correlated with age and plasma PAI-1, von Willebrand factor, fibrinogen, LDL-cholesterol, and triglycerides (p < 0.001). All these CLT assays had no significant correlations with platelet aggregation/secretion, platelet counts, and pro-coagulant tests to explore factor X activation by platelets, PRP clotting time, and thrombin generation in PRP. Among all the studied variables, PFP-CLT was independently associated with plasma PAI-1, LDL-cholesterol, and triglycerides and, additionally, stimulated PRP-CLT was also independently associated with plasma fibrinogen. A single 1 g dose of TXA strikingly prolonged all three CLTs, but in contrast to the results without the drug, the lysis times were substantially shorter in non-stimulated or stimulated PRP than in PFP and PPP. This standardized PRP-CLT may become a useful tool to study the role of platelets in clot resistance and lysis. Our results suggest that initially, the platelets enmeshed in the clot slow down the fibrinolysis process. However, the increased clot resistance to lysis induced by TXA is overcome earlier in platelet-rich clots than in PFP or PPP clots. This is likely explained by the display of platelet pro-fibrinolytic effects. Focused research is needed to disclose the mechanisms for the relationship between CLT and plasma cholesterol and its potential pathophysiologic and clinical relevance.
The shift-invariant discrete wavelet transform and application to speech waveform analysis.
Enders, Jörg; Geng, Weihua; Li, Peijun; Frazier, Michael W; Scholl, David J
2005-04-01
The discrete wavelet transform may be used as a signal-processing tool for visualization and analysis of nonstationary, time-sampled waveforms. The highly desirable property of shift invariance can be obtained at the cost of a moderate increase in computational complexity, and accepting a least-squares inverse (pseudoinverse) in place of a true inverse. A new algorithm for the pseudoinverse of the shift-invariant transform that is easier to implement in array-oriented scripting languages than existing algorithms is presented together with self-contained proofs. Representing only one of the many and varied potential applications, a recorded speech waveform illustrates the benefits of shift invariance with pseudoinvertibility. Visualization shows the glottal modulation of vowel formants and frication noise, revealing secondary glottal pulses and other waveform irregularities. Additionally, performing sound waveform editing operations (i.e., cutting and pasting sections) on the shift-invariant wavelet representation automatically produces quiet, click-free section boundaries in the resulting sound. The capabilities of this wavelet-domain editing technique are demonstrated by changing the rate of a recorded spoken word. Individual pitch periods are repeated to obtain a half-speed result, and alternate individual pitch periods are removed to obtain a double-speed result. The original pitch and formant frequencies are preserved. In informal listening tests, the results are clear and understandable.
The shift-invariant discrete wavelet transform and application to speech waveform analysis
NASA Astrophysics Data System (ADS)
Enders, Jörg; Geng, Weihua; Li, Peijun; Frazier, Michael W.; Scholl, David J.
2005-04-01
The discrete wavelet transform may be used as a signal-processing tool for visualization and analysis of nonstationary, time-sampled waveforms. The highly desirable property of shift invariance can be obtained at the cost of a moderate increase in computational complexity, and accepting a least-squares inverse (pseudoinverse) in place of a true inverse. A new algorithm for the pseudoinverse of the shift-invariant transform that is easier to implement in array-oriented scripting languages than existing algorithms is presented together with self-contained proofs. Representing only one of the many and varied potential applications, a recorded speech waveform illustrates the benefits of shift invariance with pseudoinvertibility. Visualization shows the glottal modulation of vowel formants and frication noise, revealing secondary glottal pulses and other waveform irregularities. Additionally, performing sound waveform editing operations (i.e., cutting and pasting sections) on the shift-invariant wavelet representation automatically produces quiet, click-free section boundaries in the resulting sound. The capabilities of this wavelet-domain editing technique are demonstrated by changing the rate of a recorded spoken word. Individual pitch periods are repeated to obtain a half-speed result, and alternate individual pitch periods are removed to obtain a double-speed result. The original pitch and formant frequencies are preserved. In informal listening tests, the results are clear and understandable. .
Pinheiro, Antonio Luiz B; Soares, Luiz Guilherme P; Marques, Aparecida Maria C; Aciole, Jouber Mateus S; de Souza, Renato Aparecido; Silveira, Landulfo
2014-09-05
This work aimed to assess biochemical changes associated to mineralization and remodeling of bone defects filled with Hydroxyapatite+Beta-Beta-tricalcium phosphate irradiated or not with 2 light sources. Ratios of intensities, band position and bandwidth of selected Raman peaks of collagen and apatites were used. Sixty male Wistar rats were divided into 6 groups subdivided into 2 subgroups (15th and 30th days). A standard surgical defect was created on one femur of each animal. In 3 groups the defects were filled with blood clot (Clot, Clot+Laser and Clot+LED groups) and in the remaining 3 groups the defects were filled with biomaterial (Biomaterial, Biomaterial+Laser and Biomaterial+LED groups). When indicated, the defects were irradiated with either Laser (λ780 nm, 70 mW, Φ∼0.4 cm(2)) or LED (λ850±10 nm, 150 mW, Φ∼0.5 cm(2)), 20 J/cm(2) each session, at 48 h intervals/2 weeks (140 J/cm(2) treatment). Following sacrifice, bone fragments were analyzed by Raman spectroscopy. Statistical analysis (ANOVA General Linear Model, p<0.05) showed that both grafting and time were the variables that presented significance for the ratios of ∼1660/∼1670 cm(-1) (collagen maturation), ∼1077/∼854 cm(-1) (mineralization), ∼1077/∼1070 cm(-1) (carbonate substitution) and the position of the ∼960 cm(-1) (bone maturation). At 30th day, the ratios indicated an increased deposition of immature collagen for both Clot and Biomaterial groups. Biomaterial group showed increased collagen maturation. Only collagen deposition was significantly dependent upon irradiation independently of the light source, being the amount of collagen I increased in the Clot group at the end of the experimental time. On the other hand, collagen I deposition was reduced in biomaterial irradiated groups. Raman ratios of selected protein matrix and phosphate and carbonate HA indicated that the use of biphasic synthetic micro-granular HA+Beta-TCP graft improved the repair of bone defects, associated or not with Laser or LED light, because of the increasing deposition of HA. Copyright © 2014 Elsevier B.V. All rights reserved.
Carron, Michele; Bertini, Diana; Prandini, Tancredi; Fanton, Francesca; Foletto, Mirto; Ori, Carlo; Perissinotto, Egle; Simioni, Paolo
2018-02-01
Sugammadex, which is used to reverse rocuronium-induced neuromuscular blockade, has a limited and transient effect on activated partial thromboplastin time and prothrombin time. However, no data are available on the effects of sugammadex on coagulation in morbidly obese patients, as assessed by rotational thromboelastometry (ROTEM®). Sixty patients received sugammadex 2 mg/kg or 4 mg/kg to reverse moderate or deep rocuronium-induced neuromuscular blockade (N.=30/group) at the end of surgery under desflurane anesthesia. Arterial blood samples were collected before and 3 min and 30 min after sugammadex administration for ROTEM® analysis, including measurements of clotting time (CT), clot formation time, α angle, and maximum clot firmness in INTEM, EXTEM, and FIBTEM assays. Major and minor bleeding events were also monitored during the postoperative period. Sugammadex 2 and 4 mg/kg has a limited and transient (<30 min) effect on INTEM CTs of 7.7% (P=0.04) and 10.7% (P<0.0001), respectively. There were no relevant effects on other ROTEM® parameters. A multivariate analysis indicated a significant effect of total sugammadex dose (<250, 250-500, >500 mg) on the INTEM CT (P=0.002). A regression analysis showed a positive relationship between sugammadex dose and INTEM CT value at 3 min after administration (coefficient = 0.052 s; 95% CI: 0.005-0.098 s; P=0.03). No major or minor bleeding events were observed in either group during the postoperative period. Sugammadex produces a slight effect on coagulation in morbidly obese patients, without increasing the risk for postoperative bleeding.
Estimating Extracellular Spike Waveforms from CA1 Pyramidal Cells with Multichannel Electrodes
Molden, Sturla; Moldestad, Olve; Storm, Johan F.
2013-01-01
Extracellular (EC) recordings of action potentials from the intact brain are embedded in background voltage fluctuations known as the “local field potential” (LFP). In order to use EC spike recordings for studying biophysical properties of neurons, the spike waveforms must be separated from the LFP. Linear low-pass and high-pass filters are usually insufficient to separate spike waveforms from LFP, because they have overlapping frequency bands. Broad-band recordings of LFP and spikes were obtained with a 16-channel laminar electrode array (silicone probe). We developed an algorithm whereby local LFP signals from spike-containing channel were modeled using locally weighted polynomial regression analysis of adjoining channels without spikes. The modeled LFP signal was subtracted from the recording to estimate the embedded spike waveforms. We tested the method both on defined spike waveforms added to LFP recordings, and on in vivo-recorded extracellular spikes from hippocampal CA1 pyramidal cells in anaesthetized mice. We show that the algorithm can correctly extract the spike waveforms embedded in the LFP. In contrast, traditional high-pass filters failed to recover correct spike shapes, albeit produceing smaller standard errors. We found that high-pass RC or 2-pole Butterworth filters with cut-off frequencies below 12.5 Hz, are required to retrieve waveforms comparable to our method. The method was also compared to spike-triggered averages of the broad-band signal, and yielded waveforms with smaller standard errors and less distortion before and after the spike. PMID:24391714
A Synthetic Fibrin-Crosslinking Polymer for Modulating Clot Properties and Inducing Hemostasis
Chan, Leslie W.-G.; Wang, Xu; Wei, Hua; Pozzo, Lilo D.; White, Nathan J.; Pun, Suzie H.
2015-01-01
Clotting factor replacement is the standard management of acute bleeding in congenital and acquired bleeding disorders. We present a synthetic approach to hemostasis using an engineered hemostatic polymer (PolySTAT) that circulates innocuously in the blood, identifies sites of vascular injury, and promotes clot formation to stop bleeding. PolySTAT induces hemostasis by crosslinking the fibrin matrix within clots, mimicking the function of the transglutaminase Factor XIII. Furthermore, synthetic PolySTAT binds specifically to fibrin monomers and is uniformly integrated into fibrin fibers during fibrin polymerization, resulting in a fortified, hybrid polymer network with enhanced resistance to enzymatic degradation. In vivo hemostatic activity was confirmed in a rat model of trauma and fluid resuscitation in which intravenous administration of PolySTAT improved survival by reducing blood loss and resuscitation fluid requirements. PolySTAT-induced fibrin crosslinking is a novel approach to hemostasis utilizing synthetic polymers for non-invasive modulation of clot architecture with potentially wide-ranging therapeutic applications. PMID:25739763
Comparison of the milk-clotting properties of three plant extracts.
Mazorra-Manzano, Miguel A; Perea-Gutiérrez, Teresa C; Lugo-Sánchez, María E; Ramirez-Suarez, Juan C; Torres-Llanez, María J; González-Córdova, Aarón F; Vallejo-Cordoba, Belinda
2013-12-01
Several proteases from plant sources have been proposed as milk coagulants, however, limited research has been done on their milk-clotting properties. The effect of temperature on the milk-clotting activity of kiwi fruit, melon and ginger extracts was evaluated, as well as the effects of the different extracts on curd properties. Melon extracts showed high milk-clotting activity over a broad temperature range (45-75 °C) while kiwi fruit and ginger extracts showed high activity over a narrower temperature range, with a maximum at 40 and 63 °C, respectively. Curds produced using kiwi extracts had textural properties comparable with those obtained using commercial rennet, while melon extracts produced a fragile gel and low curd yield. The milk-clotting behavior of the three plant extracts was related to the protease specificity present in these extracts. The kiwi proteases displayed chymosin-like properties and thus hold the best potential for use as a milk coagulant in cheese production. Copyright © 2013 Elsevier Ltd. All rights reserved.
Vankayala, Raviraj; Corber, Samantha R; Mac, Jenny T; Rao, Masaru P; Shafie, Mohammad; Anvari, Bahman
2018-04-01
Ischemic stroke occurs when a blood clot obstructs or narrows the arteries that supply blood to the brain. Currently, tissue plasminogen activator (tPA), a thrombolytic agent, is the only United States Food and Drug Administration (FDA)-approved pharmacologic treatment for ischemic stroke. Despite its effective usage, the major limitation of tPA that stems from its short half-life in plasma (≈5 min) is the potential for increased risk of hemorrhagic complications. To circumvent these limitations, herein, the first proof-of-principle demonstration of a theranostic nanoconstruct system derived from erythrocytes doped with the FDA-approved near-infrared (NIR) imaging agent, indocyanine green, and surface-functionalized with tPA is reported. Using a clot model, the dual functionality of these nanoconstructs in NIR fluorescence imaging and clot lysis is demonstrated. These biomimetic theranostic nanoconstructs may ultimately be effective in imaging and treatment of blood clots involved in ischemic stroke. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tumour imaging by the detection of fibrin clots in tumour stroma using an anti-fibrin Fab fragment.
Obonai, Toshifumi; Fuchigami, Hirobumi; Furuya, Fumiaki; Kozuka, Naoyuki; Yasunaga, Masahiro; Matsumura, Yasuhiro
2016-03-24
The diagnosis of early and aggressive types of cancer is important for providing effective cancer therapy. Cancer-induced fibrin clots exist only within lesions. Previously, we developed a monoclonal antibody (clone 102-10) that recognizes insoluble fibrin but not fibrinogen or soluble fibrin and confirmed that fibrin clots form continuously in various cancers. Here, we describe the development of a Fab fragment probe of clone 102-10 for tumour imaging. The distribution of 102-10 Fab was investigated in genetically engineered mice bearing pancreatic ductal adenocarcinoma (PDAC), and its effect on blood coagulation was examined. Immunohistochemical and ex vivo imaging revealed that 102-10 Fab was distributed selectively in fibrin clots in PDAC tumours 3 h after injection and that it disappeared from the body after 24 h. 102-10 Fab had no influence on blood coagulation or fibrinolysis. Tumour imaging using anti-fibrin Fab may provide a safe and effective method for the diagnosis of invasive cancers by detecting fibrin clots in tumour stroma.
Sánchez-Muñoz, María Alejandra; Valdez-Solana, Mónica Andrea; Avitia-Domínguez, Claudia; Ramírez-Baca, Patricia; Candelas-Cadillo, María Guadalupe; Aguilera-Ortíz, Miguel; Meza-Velázquez, Jorge Armando; Téllez-Valencia, Alfredo; Sierra-Campos, Erick
2017-01-01
In this study, the potential use of Moringa oleifera as a clotting agent of different types of milk (whole, skim, and soy milk) was investigated. M. oleifera seed extract showed high milk-clotting activity followed by flower extract. Specific clotting activity of seed extract was 200 times higher than that of flower extract. Seed extract is composed by four main protein bands (43.6, 32.2, 19.4, and 16.3 kDa). Caseinolytic activity assessed by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) and tyrosine quantification, showed a high extent of casein degradation using M. oleifera seed extract. Milk soy cheese was soft and creamy, while skim milk cheese was hard and crumbly. According to these results, it is concluded that seed extract of M. oleifera generates suitable milk clotting activity for cheesemaking. To our knowledge, this study is the first to report comparative data of M. oleifera milk clotting activity between different types of soy milk. PMID:28783066
Sánchez-Muñoz, María Alejandra; Valdez-Solana, Mónica Andrea; Avitia-Domínguez, Claudia; Ramírez-Baca, Patricia; Candelas-Cadillo, María Guadalupe; Aguilera-Ortíz, Miguel; Meza-Velázquez, Jorge Armando; Téllez-Valencia, Alfredo; Sierra-Campos, Erick
2017-08-05
In this study, the potential use of Moringa oleifera as a clotting agent of different types of milk (whole, skim, and soy milk) was investigated. M. oleifera seed extract showed high milk-clotting activity followed by flower extract. Specific clotting activity of seed extract was 200 times higher than that of flower extract. Seed extract is composed by four main protein bands (43.6, 32.2, 19.4, and 16.3 kDa). Caseinolytic activity assessed by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) and tyrosine quantification, showed a high extent of casein degradation using M. oleifera seed extract. Milk soy cheese was soft and creamy, while skim milk cheese was hard and crumbly. According to these results, it is concluded that seed extract of M. oleifera generates suitable milk clotting activity for cheesemaking. To our knowledge, this study is the first to report comparative data of M. oleifera milk clotting activity between different types of soy milk.
Graham, John B.; Buckwalter, Joseph A.; Hartley, L. J.; Brinkhous, Kenneth M.
1949-01-01
A study was made of the clotting defect and the course of the malady in a group of male dogs with an inherited, sex-linked bleeding disease. The clotting defect is characterized by a prolonged clotting time and a delayed prothrombin utilization, and is corrected by the addition either of thromboplastin or of normal plasma. A plasma protein fraction, fraction I, also corrects the defect. The defect appears to be due to a deficiency of a plasma factor, which normally, in the presence of platelets, makes thromboplastin available in shed blood. The clotting anomaly appears to be identical with that found in human hemophilia. The hemostatic defect is characterized by repeated hemorrhages, usually without obvious relationship to trauma. Hemarthroses occur frequently and may result in permanent joint deformity. The animals usually die early in life from massive hemorrhage. Transfusions with normal blood or plasma correct the clotting defect and readily control the hemorrhagic phenomena. By the use of transfusions, these dogs have been reared to maturity. PMID:18136192
Talin-dependent integrin activation is required for fibrin clot retraction by platelets
Haling, Jacob R.; Monkley, Susan J.; Critchley, David R.
2011-01-01
Talin functions both as a regulator of integrin affinity and as an important mechanical link between integrins and the cytoskeleton. Using genetic deletion of talin, we show for the first time that the capacity of talin to activate integrins is required for fibrin clot retraction by platelets. To further dissect which talin functions are required for this process, we tested clot retraction in platelets expressing a talin1(L325R) mutant that binds to integrins, but exhibits impaired integrin activation ascribable to disruption of the interaction between talin and the membrane-proximal region (MPR) in the β-integrin cytoplasmic domain. Talin-deficient and talin1(L325R) platelets were defective in retracting fibrin clots. However, the defect in clot retraction in talin1(L325R) platelets, but not talin-deficient platelets, was rescued by extrinsically activating integrins with manganese, thereby proving that integrin activation is required and showing that talin1(L325R) can form functional links to the actin cytoskeleton. PMID:20971947
Positive interference in lithium determinations from clot activator in collection container.
Sampson, M; Ruddel, M; Albright, S; Elin, R J
1997-04-01
We describe positive interference with the ion-selective electrode determination of lithium (Lytening 2Z analyzer; Dade) when blood is collected in a 10-mL plain red-top plastic Vacutainer Plus Tube (Becton Dickinson) containing a silica clot activator and silicone surfactant (prod. no. 36-7820). We evaluated both the original tube (blue-labeled) and a new tube formulated to contain less silicone surfactant (striped-labeled). We determined that the interference is from either the silica clot activator or the silicone surfactant used to fix the silica to the tube and is inversely related to the volume of blood in the tube. Long-term intermittent exposure of the Li ion-selective electrode to the silica clot activator or surfactant results in decreased Li values--in terms of both the positive interference by the silica clot activator or surfactant and the actual Li determinations. Moreover, this long-term interference with the Li ion-selective electrode for patient's specimens is undetected by the Dade control material (QCLytes).
Oldenburg, Amy L.; Wu, Gongting; Spivak, Dmitry; Tsui, Frank; Wolberg, Alisa S.; Fischer, Thomas H.
2013-01-01
Improved methods for imaging and assessment of vascular defects are needed for directing treatment of cardiovascular pathologies. In this paper, we employ magnetomotive optical coherence tomography (MMOCT) as a platform both to detect and to measure the elasticity of blood clots. Detection is enabled through the use of rehydrated, lyophilized platelets loaded with superparamagnetic iron oxides (SPIO-RL platelets) that are functional infusion agents that adhere to sites of vascular endothelial damage. Evidence suggests that the sensitivity for detection is improved over threefold by magnetic interactions between SPIOs inside RL platelets. Using the same MMOCT system, we show how elastometry of simulated clots, using resonant acoustic spectroscopy, is correlated with the fibrin content of the clot. Both methods are based upon magnetic actuation and phase-sensitive optical monitoring of nanoscale displacements using MMOCT, underscoring its utility as a broad-based platform to detect and measure the molecular structure and composition of blood clots. PMID:23833549
Raine, Dan; Langley, Philip; Murray, Alan; Dunuwille, Asunga; Bourke, John P
2004-09-01
The aims of this study were to evaluate (1) principal component analysis as a technique for extracting the atrial signal waveform from the standard 12-lead ECG and (2) its ability to distinguish changes in atrial fibrillation (AF) frequency parameters over time and in response to pharmacologic manipulation using drugs with different effects on atrial electrophysiology. Twenty patients with persistent AF were studied. Continuous 12-lead Holter ECGs were recorded for 60 minutes, first, in the drug-free state. Mean and variability of atrial waveform frequency were measured using an automated computer technique. This extracted the atrial signal by principal component analysis and identified the main frequency component using Fourier analysis. Patients were then allotted sequentially to receive 1 of 4 drugs intravenously (amiodarone, flecainide, sotalol, or metoprolol), and changes induced in mean and variability of atrial waveform frequency measured. Mean and variability of atrial waveform frequency did not differ within patients between the two 30-minute sections of the drug-free state. As hypothesized, significant changes in mean and variability of atrial waveform frequency were detected after manipulation with amiodarone (mean: 5.77 vs 4.86 Hz; variability: 0.55 vs 0.31 Hz), flecainide (mean: 5.33 vs 4.72 Hz; variability: 0.71 vs 0.31 Hz), and sotalol (mean: 5.94 vs 4.90 Hz; variability: 0.73 vs 0.40 Hz) but not with metoprolol (mean: 5.41 vs 5.17 Hz; variability: 0.81 vs 0.82 Hz). A technique for continuously analyzing atrial frequency characteristics of AF from the surface ECG has been developed and validated.
Thrombi produced in stagnation point flows have a core-shell structure.
Herbig, Bradley A; Diamond, Scott L
2017-12-01
In regions of flow separation/reattachment within diseased arteries, the local hemodynamics can result in stagnation point flow that provides an atypical environment in atherosclerosis. Impinging flows occur with recirculation eddies distal of coronary stenosis or diseased carotid bifurcations. By perfusing whole blood directly perpendicular to a fibrillar collagen thrombotic surface, a microfluidic device produced a stagnation point flow. Side view visualization of thrombosis in this assay allowed for observation of clot structure and composition at various flow rates and blood biochemistry conditions. For clotting over collagen/tissue factor surfaces, platelet thrombi formed in this device displayed a core-shell architecture with a fibrin-rich, platelet P-selectin-positive core and an outer platelet P-selectin-negative shell. VWF was detected in clots at low and high shear, but when N-acetylcysteine was added to the whole blood, both platelet and VWF deposition were markedly decreased at either low or high flow. To further examine the source of clot stability, 1 mM GPRP was added to prevent fibrin formation while allowing the PAR1/4-cleaving activity of thrombin to progress. The inhibition of fibrin polymerization did not change the overall structure of the clots, demonstrating the stability of these clots without fibrin. Impinging flow microfluidics generate thrombi with a core-shell structure.
Zamolodchikov, Daria
2012-01-01
Alzheimer disease is characterized by the presence of increased levels of the β-amyloid peptide (Aβ) in the brain parenchyma and cerebral blood vessels. This accumulated Aβ can bind to fibrin(ogen) and render fibrin clots more resistant to degradation. Here, we demonstrate that Aβ42 specifically binds to fibrin and induces a tighter fibrin network characterized by thinner fibers and increased resistance to lysis. However, Aβ42-induced structural changes cannot be the sole mechanism of delayed lysis because Aβ overlaid on normal preformed clots also binds to fibrin and delays lysis without altering clot structure. In this regard, we show that Aβ interferes with the binding of plasminogen to fibrin, which could impair plasmin generation and fibrin degradation. Indeed, plasmin generation by tissue plasminogen activator (tPA), but not streptokinase, is slowed in fibrin clots containing Aβ42, and clot lysis by plasmin, but not trypsin, is delayed. Notably, plasmin and tPA activities, as well as tPA-dependent generation of plasmin in solution, are not decreased in the presence of Aβ42. Our results indicate the existence of 2 mechanisms of Aβ42 involvement in delayed fibrinolysis: (1) through the induction of a tighter fibrin network composed of thinner fibers, and (2) through inhibition of plasmin(ogen)–fibrin binding. PMID:22238323
Silva, Raúl F; Carmona, Jorge U; Rezende, Cleuza M F
2013-04-15
The aim of this study was to use transmission electron microscopy to describe the ultrastructural characteristics of clots obtained from canine and feline platelet concentrates (PC) that had been activated with calcium gluconate (CG) or CG plus batroxobin (CGB). Platelets from fibrin clots were classified according their morphological changes. The area of the intercellular space (μm2), the area of the fibrin fibers (μm2), and the width of the fibrin fibers (μm) were determined for the dog clots. The platelet area (μm2), the area of fibrin fibers (μm2), the ratio of the minor and major axes of platelets, the ratio of the major and minor axes of platelets, and the number of α-granules found within platelets were measured for the cat clots. Cat platelets displayed full activation. Dog platelets displayed lysis with loss of normal architecture. In both species, a statistically significant difference was found (P < 0.01) between the fibrin fiber measurements in the PC clots activated with CG and CGB. The findings suggest that activation with CG caused platelet alpha granules to release their contents. In cats, fibrin production was greater when the PC was activated with CG. In dogs, activation with CG produced thick fibrin fibers.
In microfluidico: Recreating in vivo hemodynamics using miniaturized devices
Zhu, Shu; Herbig, Bradley A.; Li, Ruizhi; Colace, Thomas V.; Muthard, Ryan W.; Neeves, Keith B.; Diamond, Scott L.
2016-01-01
Microfluidic devices create precisely controlled reactive blood flows and typically involve: (i) validated anticoagulation/pharmacology protocols, (ii) defined reactive surfaces, (iii) defined flow-transport regimes, and (iv) optical imaging. An 8-channel device can be run at constant flow rate or constant pressure drop for blood perfusion over a patterned collagen, collagen/kaolin, or collagen/tissue factor (TF) to measure platelet, thrombin, and fibrin dynamics during clot growth. A membrane-flow device delivers a constant flux of platelet agonists or coagulation enzymes into flowing blood. A trifurcated device sheaths a central blood flow on both sides with buffer, an ideal approach for on-chip recalcification of citrated blood or drug delivery. A side-view device allows clotting on a porous collagen/TF plug at constant pressure differential across the developing clot. The core-shell architecture of clots made in mouse models can be replicated in this device using human blood. For pathological flows, a stenosis device achieves shear rates of >100,000 s−1 to drive plasma von Willebrand factor (VWF) to form thick long fibers on collagen. Similarly, a micropost-impingement device creates extreme elongational and shear flows for VWF fiber formation without collagen. Overall, microfluidics are ideal for studies of clotting, bleeding, fibrin polymerization/fibrinolysis, cell/clot mechanics, adhesion, mechanobiology, and reaction-transport dynamics. PMID:26600269
Schmidt, David E; Halmin, Märit; Wikman, Agneta; Östlund, Anders; Ågren, Anna
2017-10-01
Massive traumatic haemorrhage is aggravated through the development of trauma-induced coagulopathy, which is managed by plasma transfusion and/or fibrinogen concentrate administration. It is yet unclear whether these treatments are equally potent in ensuring adequate haemostasis, and whether additional factor XIII (FXIII) administration provides further benefits. In this study, we compared ROTEM whole blood coagulation profiles after experimental massive transfusion with different transfusion regimens in an in vitro model of dilution- and transfusion-related coagulopathy. Healthy donor blood was mixed 1 + 1 with six different transfusion regimens. Each regimen contained RBC, platelet concentrate, and either fresh frozen plasma (FFP) or Ringer's acetate (RA). The regimens were further augmented through addition of a low- or medium-dose fibrinogen concentrate and FXIII. Transfusion with FFP alone was insufficient to maintain tissue-factor activated clot strength, coincidental with a deficiency in fibrin-based clot strength. Fibrinogen concentrate conserved, but did not improve coagulation kinetics and overall clot strength. Only combination therapy with FFP and low-dose fibrinogen concentrate improved both coagulation kinetics and fibrin-based clot strength. Administration of FXIII did not result in an improvement of clot strength. In conclusion, combination therapy with both FFP and low-dose fibrinogen concentrate improved clotting time and produced firm clots, representing a possible preferred first-line regimen to manage trauma-induced coagulopathy when RBC and platelets are also transfused. Further research is required to identify optimal first-line transfusion fluids for massive traumatic haemorrhage.
Brinkman, Arinda C M; Romijn, Johannes W A; van Barneveld, Lerau J M; Greuters, Sjoerd; Veerhoek, Dennis; Vonk, Alexander B A; Boer, Christa
2010-06-01
Dilutional coagulopathy as a consequence of cardiopulmonary bypass (CPB) system priming may also be affected by the composition of the priming solution. The direct effects of distinct priming solutions on fibrinogen, one of the foremost limiting factors during dilutional coagulopathy, have been minimally evaluated. Therefore, the authors investigated whether hemodilution with different priming solutions distinctly affects the fibrinogen-mediated step in whole blood clot formation. Prospective observational laboratory study. University hospital laboratory. Eight male healthy volunteers. Blood samples diluted with gelatin-, albumin-, or hydroxyethyl starch (HES)-based priming solutions were ex-vivo evaluated for clot formation by rotational thromboelastometry. The intrinsic pathway (INTEM) coagulation time increased from 186 +/- 19 seconds to 205 +/- 16, 220 +/- 17, and 223 +/- 18 seconds after dilution with gelatin-, albumin-, or HES-containing prime solutions (all p < 0.05 v baseline). The extrinsic pathway (EXTEM) coagulation time was only minimally affected by hemodilution. Moreover, all 3 priming solutions significantly reduced the INTEM and EXTEM maximum clot firmness. The HES-containing priming solution induced the largest decrease in the maximum clot firmness attributed to fibrinogen, from 13 +/- 1 mm (baseline) to 6 +/- 1 mm (p < 0.01 v baseline). All studied priming solutions prolonged coagulation time and decreased clot formation, but the fibrinogen-limiting effect was the most profound for the HES-containing priming solution. These results suggest that the composition of priming solutions may distinctly affect blood clot formation, in particular with respect to the fibrinogen component in hemostasis. Copyright 2010 Elsevier Inc. All rights reserved.
Development of a microplate coagulation assay for Factor V in human plasma.
Tilley, Derek; Levit, Irina; Samis, John A
2011-06-28
Factor V (FV) in its activated form, FVa, is a critical regulator of thrombin generation during fibrin clot formation. There is a need of a simple, fast, and inexpensive microplate-based coagulation assay to measure the functional activity of FV in human plasma. The objective of this study was to develop a microplate-based assay that measures FV coagulation activity during clot formation in human plasma, which is currently not available. The FV assay requires a kinetic microplate reader to measure the change in absorbance at 405nm during fibrin formation in human plasma. The FV assay accurately measures the time, initial rate, and extent of fibrin clot formation in human plasma. The FV microplate assay is simple, fast, economical, sensitive to approx 24-80pM, and multiple samples may be analyzed simultaneously. All the required materials are commercially available. Standard curves of time or initial rate of fibrin clot formation vs FV activity in the 1-stage assay (Without activation by thrombin) may be used to measure FV activity in samples of human plasma. The assay was used to demonstrate that in nine patients with disseminated intravascular coagulation (DIC), the FV 1-stage, 2-stage (With activation by thrombin), and total (2-stage activity - 1-stage activity) activities were decreased, on average, by approximately 54%, 44%, and 42%, respectively, from prolonged clot times when compared to normal pooled human reference plasma (NHP). The results indicate that the FV in the DIC patient plasmas supported both a delayed and slower rate of fibrin clot formation compared with NHP; however, the extent of fibrin clot formation in the DIC patients remained largely unchanged from that observed with NHP. The FV microplate assay may be easily adapted to measure the activity of any coagulation factor using the appropriate factor-deficient plasma and clot initiating reagent. The microplate assay will find use in both research and clinical laboratories to provide measurement of the functional coagulation activity of FV in human plasma.
Pretorius, Etheresia; Bester, Janette
2016-08-09
Type 2 diabetes patients (T2D) have a considerably higher cardiovascular risk, which is closely associated with systemic inflammation, and an accompanying pathologic coagulation system. Due to the complexity of the diabetic profile, we suggest that we need to look at each patient individually and particularly at his or her clotting profile; as the healthiness of the coagulation system gives us an indication of the success of clinical intervention. T2D coagulability varied markedly, although there were no clear difference in medication use and the standards of HbA1c levels. Our sample consisted of 90 poorly controlled T2D and 71 healthy individuals. We investigated the medication use and standards of HbA1c levels of T2D and we used thromboelastography (TEG) and scanning electron microscopy (SEM) to study their clot formation. The latest NIH guidelines suggest that clinical medicine should focus on precision medicine, and the current broad understanding is that precision medicine may in future, provide personalized targets for preventative and therapeutic interventions. Here we suggest a practical example where TEG can be used as an easily accessible point-of-care tool to establish a comprehensive clotting profile analysis for T2D patients; and additionally may provide valuable information that may be used in the envisaged precision medicine approach. Only by closely following each individual patient's progress and healthiness and thereby managing systemic inflammation, will we be able to reduce this pandemic.
NASA Astrophysics Data System (ADS)
Bai, Guang-Fu; Hu, Lin; Jiang, Yang; Tian, Jing; Zi, Yue-Jiao; Wu, Ting-Wei; Huang, Feng-Qin
2017-08-01
In this paper, a photonic microwave waveform generator based on a dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. In this reported scheme, only one radio frequency signal is used to drive the dual-parallel Mach-Zehnder modulator. Meanwhile, dispersive elements or filters are not required in the proposed scheme, which make the scheme simpler and more stable. In this way, six variables can be adjusted. Through the different combinations of these variables, basic waveforms with full duty and small duty cycle can be generated. Tunability of the generator can be achieved by adjusting the frequency of the RF signal and the optical carrier. The corresponding theoretical analysis and simulation have been conducted. With guidance of theory and simulation, proof-of-concept experiments are carried out. The basic waveforms, including Gaussian, saw-up, and saw-down waveforms, with full duty and small duty cycle are generated at the repetition rate of 2 GHz. The theoretical and simulation results agree with the experimental results very well.
Consistency of Post-Newtonian Waveforms with Numerical Relativity
NASA Technical Reports Server (NTRS)
Baker, John G.; vanMeter, James R.; McWilliams, Sean T.; Centrella, Joan; Kelly, Bernard J.
2007-01-01
General relativity predicts the gravitational radiation signatures of mergers of compact binaries,such as coalescing binary black hole systems. Derivations of waveform predictions for such systems are required for optimal scientific analysis of observational gravitational wave data, and have so far been achieved primarily with the aid of the post-Newtonian (PN) approximation. The quaIity of this treatment is unclear, however, for the important late inspiral portion. We derive late-inspiral wave forms via a complementary approach, direct numerical simulation of Einstein's equations, which has recently matured sufficiently for such applications. We compare waveform phasing from simulations covering the last approximately 14 cycles of gravitational radiation from an equal-mass binary system of nonspinning black holes with corresponding 3PN and 3.5PN waveforms. We find phasing agreement consistent with internal error estimates based in either approach, at the level of one radian over approximately 10 cycles. The result suggests that PN waveforms for this system are effective roughly until the system reaches its last stable orbit just prior to the final merger.
Real-time digital signal recovery for a multi-pole low-pass transfer function system.
Lee, Jhinhwan
2017-08-01
In order to solve the problems of waveform distortion and signal delay by many physical and electrical systems with multi-pole linear low-pass transfer characteristics, a simple digital-signal-processing (DSP)-based method of real-time recovery of the original source waveform from the distorted output waveform is proposed. A mathematical analysis on the convolution kernel representation of the single-pole low-pass transfer function shows that the original source waveform can be accurately recovered in real time using a particular moving average algorithm applied on the input stream of the distorted waveform, which can also significantly reduce the overall delay time constant. This method is generalized for multi-pole low-pass systems and has noise characteristics of the inverse of the low-pass filter characteristics. This method can be applied to most sensors and amplifiers operating close to their frequency response limits to improve the overall performance of data acquisition systems and digital feedback control systems.
Consistency of Post-Newtonian Waveforms with Numerical Relativity
NASA Technical Reports Server (NTRS)
Baker, John G.; vanMeter, James R.; McWilliams, Sean T.; Cewntrella, Joan; Kelly, Bernard J.
2006-01-01
General relativity predicts the gravitational radiation signatures of mergers of compact binaries, such as coalescing binary black hole systems. Derivations of waveform predictions for such systems are required for optimal scientific analysis of observational gravitational wave data, and have so far been achieved primarily with the aid of the post-Newtonian (PN) approximation. The quality of this treatment is unclear, however, for the important late inspiral portion. We derive late-inspiral waveforms via a complementary approach, direct numerical simulation of Einstein's equations, which has recently matured sufficiently for such applications. We compare waveform phasing from simulations covering the last approximately 14 cycles of gravitational radiation from an equal-mass binary system of nonspinning black holes with the corresponding 3PN and 3.5PN orbital phasing. We find agreement consistent with internal error estimates based on either approach at the level of one radian over approximately 10 cycles. The result suggests that PN waveforms for this system are effective roughly until the system reaches its last stable orbit just prior to the final merger/
Amiral, Jean; Vissac, Anne Marie; Seghatchian, Jerard
2017-12-01
Activated Protein C Resistance is mainly associated to a factor V mutation (RQ506), which induces a deficient inactivation of activated factor V by activated protein C, and is associated to an increased risk of venous and arterial thrombosis in affected individuals, caused by the prolonged activated factor V survival. Its prevalence is mainly in Caucasians (about 5%), and this mutation is absent in Africans and Asians. Presence of Factor V-Leiden is usually evidenced with clotting methods, using a two-step APTT assay performed without or with APC: prolongation of blood coagulation time is decreased if this factor is present. The R506Q Factor V-Leiden mutation is now usually characterized using molecular biology, and this technique tends to become the first intention assay for characterization of patients. Both techniques are qualitative, and allow classifying tested individuals as heterozygotes or homozygotes for the mutation, when present. A new quantitative assay for Factor V-Leiden, using a one-step clotting method, has been developed, and designed with highly purified human coagulation proteins. Clotting is triggered with human Factor Xa, in presence of calcium and phospholipids (mixture which favours APC action over clotting process). Diluted tested plasma, is supplemented with a clotting mixture containing human fibrinogen, prothrombin, and protein S at a constant concentration. APC is added, and clotting is initiated with calcium. Calibration is performed with a pool of plasmas from patients carrying the R506Q Factor V mutation, and its mixtures with normal plasma. Homozygous patients have clotting times of about <40sec; heterozygous patients have clotting times of about 40-60sec and normal individuals yield clotting times >70sec. Factor V-Leiden concentration is usually >75% in homozygous patients, 30-60% in heterozygous patients and below 5% in normal. The assay is insensitive to clotting factor deficiencies (II, VII, VIII: C, IX, X), dicoumarol or heparin therapies, and has no interference with lupus anticoagulant (LA). This new assay for Factor V-Leiden can be easily used in any coagulation laboratory, is performed as a single test, and is quantitative. This assay has a high robustness, is accurate and presents a good intra- (<3%) and inter-assay (<5%) variability. It contributes solving most of the laboratory issues faced when testing factor V-Leiden. Quantitation of Factor V-L could contribute to a better assessment of thrombotic risk in affected patients, as this complication is first associated to and caused by the presence of a defined amount of FVa. Copyright © 2017 Elsevier Ltd. All rights reserved.
Parks, Nathan A.; Gannon, Matthew A.; Long, Stephanie M.; Young, Madeleine E.
2016-01-01
Analysis of event-related potential (ERP) data includes several steps to ensure that ERPs meet an appropriate level of signal quality. One such step, subject exclusion, rejects subject data if ERP waveforms fail to meet an appropriate level of signal quality. Subject exclusion is an important quality control step in the ERP analysis pipeline as it ensures that statistical inference is based only upon those subjects exhibiting clear evoked brain responses. This critical quality control step is most often performed simply through visual inspection of subject-level ERPs by investigators. Such an approach is qualitative, subjective, and susceptible to investigator bias, as there are no standards as to what constitutes an ERP of sufficient signal quality. Here, we describe a standardized and objective method for quantifying waveform quality in individual subjects and establishing criteria for subject exclusion. The approach uses bootstrap resampling of ERP waveforms (from a pool of all available trials) to compute a signal-to-noise ratio confidence interval (SNR-CI) for individual subject waveforms. The lower bound of this SNR-CI (SNRLB) yields an effective and objective measure of signal quality as it ensures that ERP waveforms statistically exceed a desired signal-to-noise criterion. SNRLB provides a quantifiable metric of individual subject ERP quality and eliminates the need for subjective evaluation of waveform quality by the investigator. We detail the SNR-CI methodology, establish the efficacy of employing this approach with Monte Carlo simulations, and demonstrate its utility in practice when applied to ERP datasets. PMID:26903849
Acute epidural-like appearance of an encapsulated solid non-organized chronic subdural hematoma.
Prieto, Ruth; Pascual, José M; Subhi-Issa, Issa; Yus, Miguel
2010-01-01
We report the exceptional case of an encapsulated solid non-organized chronic subdural hematoma (SDH) in a 67-year-old woman that was admitted with acute hemiplegia followed by rapid deterioration in consciousness 5 months after a minor head trauma. Computed tomography (CT) showed an extracerebral biconvex shaped hyperdense mass that led to the misdiagnosis of an acute epidural hematoma. Urgent craniotomy revealed an encapsulated mass filled with solid fresh clot in the subdural space. Complete evacuation of this SDH, including both its inner and outer membranes, was achieved, and the patient recovered successfully. Histological analysis confirmed that the content of the hematoma corresponded to a newly formed clot that was enclosed between an inner membrane, composed of two collagen layers, and an outer membrane with a three layered structure. Chronic SDH may seldom present as an encapsulated solid non-organized lesion that consists of a fibrous capsule enclosing a fresh clot and lacking the thick fibrous septations that typically connect the inner and outer membranes of organized chronic SDH. This entity mimics the clinical course and radiological appearance of acute epidural hematomas and should be considered in the differential diagnosis of extracerebral hyperdense biconvex shaped lesions.
Mahboubi, Arash; Sadjady, Seyyed Kazem; Mirzaei Saleh Abadi, Mohammad; Azadi, Saeed; Solaimanian, Roya
2012-01-01
DETERMINATION OF STREPTOKINASE ACTIVITY IS USUALLY ACCOMPLISHED THROUGH TWO ASSAY METHODS: a) Clot lysis, b) Chromogenic substrate assay. In this study the biological activity of two streptokinase products, namely Streptase®, which is a native product and Heberkinasa®, which is a recombinant product, was determined against the third international reference standard using the two forementioned assay methods. The results indicated that whilst the activity of Streptase® was found to be 101 ± 4% and 97 ± 5% of the label claim with Clot lysis and Chromogenic substrate assay respectively, for Heberkinasa® the potency values obtained were 42 ± 5% and 92.5 ± 2% of the label claim respectively. To shed some light on the reason for this finding, the n-terminal sequence of the streptokinase molecules present in the two products was determined. The results showed slight differences in the amino acid sequence of the recombinant product in comparison to the native one at the amino terminus. This finding supports those of other workers who found that n-terminal sequence of the streptokinase molecule can have significant effect on the activity of this protein.
NASA Astrophysics Data System (ADS)
Lamb, Frederick K.; Dorris, D.; Clare, A.; Van Wassenhove, S.; Yu, W.; Miller, M. C.
2006-09-01
The spin-frequency behavior of accretion-powered millisecond pulsars is usually inferred by power spectral analysis of their X-ray waveforms. The reported behavior of the spin frequencies of several accretion-powered millisecond pulsars is puzzling in two respects. First, analysis of the waveforms of these pulsars indicates that their spin frequencies are changing faster than predicted by the standard model of accretion torques. Second, there are wild swings of both signs in their apparent spin frequencies that are not correlated with the mass accretion rates inferred from their X-ray fluxes. We have computed the expected X-ray waveforms of pulsars like these, including special and general relativistic effects, and find that the changes in their waveforms produced by physically plausible changes in the flow of accreting matter onto their surfaces can explain their apparently anomalous spin-frequency behavior. This research was supported in part by NASA grant NAG 5-12030, NSF grant AST 0098399, and funds of the Fortner Endowed Chair at Illinois, and NSF grant AST 0098436 at Maryland.
Transition in Pulsatile Pipe Flow
NASA Astrophysics Data System (ADS)
Vlachos, Pavlos; Brindise, Melissa
2016-11-01
Transition has been observed to occur in the aorta, and stenotic vessels, where pulsatile flow exists. However, few studies have investigated the characteristics and effects of transition in oscillating or pulsatile flow and none have utilized a physiological waveform. In this work, we explore transition in pipe flow using three pulsatile waveforms which all maintain the same mean and maximum flow rates and range to zero flow, as is physiologically typical. Velocity fields were obtained using planar particle image velocimetry for each pulsatile waveform at six mean Reynolds numbers ranging between 500 and 4000. Turbulent statistics including turbulent kinetic energy (TKE) and Reynolds stresses were computed. Quadrant analysis was used to identify characteristics of the production and dissipation of turbulence. Coherent structures were identified using the λci method. We developed a wavelet-Hilbert time-frequency analysis method to identify high frequency structures and compared these to the coherent structures. The results of this study demonstrate that the different pulsatile waveforms induce different levels of TKE and high frequency structures, suggesting that the rates of acceleration and deceleration influence the onset and development of transition.
Investigation of Self Triggered Cosmic Ray Detectors using Silicon Photomultiplier
NASA Astrophysics Data System (ADS)
Knox, Adrian; Niduaza, Rommel; Hernandez, Victor; Ruiz, Daniel; Ramos, Daniel; Fan, Sewan; Fatuzzo, Laura; Ritt, Stefan
2015-04-01
The silicon photomultiplier (SiPM) is a highly sensitive light detector capable of measuring single photons. It costs a fraction of the photomultiplier tube and operates slightly above the breakdown voltage. At this conference we describe our investigation of SiPM, the multipixel photon counters (MPPC) from Hamamatsu as readout detectors for plastic scintillators working for detecting cosmic ray particles. Our setup consists of scintillator sheets embedded with blue to green wavelength shifting fibers optically coupled to MPPCs to detect scintillating light. Four detector assemblies would be constructed and arranged to work in self triggered mode. Using custom matching tee boxes, the amplified MPPC signals are fed to discriminators with threshold set to give a reasonable coincidence count rate. Moreover, the detector waveforms are digitized using a 5 Giga Samples per second waveform digitizer, the DRS4, and triggered with the coincidence logic to capture the MPPC waveforms. Offline analysis of the digitized waveforms is accomplished using the CERN package PAW and results of our experiments and the data analysis would also be discussed. US Department of Education Title V Grant Number PO31S090007.
Spatiotemporal Characterization of a Fibrin Clot Using Quantitative Phase Imaging
Gannavarpu, Rajshekhar; Bhaduri, Basanta; Tangella, Krishnarao; Popescu, Gabriel
2014-01-01
Studying the dynamics of fibrin clot formation and its morphology is an important problem in biology and has significant impact for several scientific and clinical applications. We present a label-free technique based on quantitative phase imaging to address this problem. Using quantitative phase information, we characterized fibrin polymerization in real-time and present a mathematical model describing the transition from liquid to gel state. By exploiting the inherent optical sectioning capability of our instrument, we measured the three-dimensional structure of the fibrin clot. From this data, we evaluated the fractal nature of the fibrin network and extracted the fractal dimension. Our non-invasive and speckle-free approach analyzes the clotting process without the need for external contrast agents. PMID:25386701
Stewart, C M; Newlands, S D; Perachio, A A
2004-12-01
Rapid and accurate discrimination of single units from extracellular recordings is a fundamental process for the analysis and interpretation of electrophysiological recordings. We present an algorithm that performs detection, characterization, discrimination, and analysis of action potentials from extracellular recording sessions. The program was entirely written in LabVIEW (National Instruments), and requires no external hardware devices or a priori information about action potential shapes. Waveform events are detected by scanning the digital record for voltages that exceed a user-adjustable trigger. Detected events are characterized to determine nine different time and voltage levels for each event. Various algebraic combinations of these waveform features are used as axis choices for 2-D Cartesian plots of events. The user selects axis choices that generate distinct clusters. Multiple clusters may be defined as action potentials by manually generating boundaries of arbitrary shape. Events defined as action potentials are validated by visual inspection of overlain waveforms. Stimulus-response relationships may be identified by selecting any recorded channel for comparison to continuous and average cycle histograms of binned unit data. The algorithm includes novel aspects of feature analysis and acquisition, including higher acquisition rates for electrophysiological data compared to other channels. The program confirms that electrophysiological data may be discriminated with high-speed and efficiency using algebraic combinations of waveform features derived from high-speed digital records.
Mergers of black-hole binaries with aligned spins: Waveform characteristics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Bernard J.; Department of Physics, University of Maryland, Baltimore County, 1000 Hilltop Circle, Baltimore, Maryland 21250; Baker, John G.
2011-10-15
We conduct a descriptive analysis of the multipolar structure of gravitational-radiation waveforms from equal-mass aligned-spin mergers, following an approach first presented in the complementary context of nonspinning black holes of varying mass ratio [J. G. Baker et al., Phys. Rev. D 78, 044046 (2008).]. We find that, as with the nonspinning mergers, the dominant waveform mode phases evolve together in lock-step through inspiral and merger, supporting the previous waveform description in terms of an adiabatically rigid rotator driving gravitational-wave emission--an implicit rotating source. We further apply the late-time merger-ringdown model for the rotational frequency introduced in [J. G. Baker etmore » al., Phys. Rev. D 78, 044046 (2008).], along with an improved amplitude model appropriate for the dominant (2, {+-}2) modes. This provides a quantitative description of the merger-ringdown waveforms, and suggests that the major features of these waveforms can be described with reference only to the intrinsic parameters associated with the state of the final black hole formed in the merger. We provide an explicit model for the merger-ringdown radiation, and demonstrate that this model agrees to fitting factors better than 95% with the original numerical waveforms for system masses above {approx}150M{sub {center_dot}}. This model may be directly applicable to gravitational-wave detection of intermediate-mass black-hole mergers.« less
A Fiber Bragg Grating Sensor for Radial Artery Pulse Waveform Measurement.
Jia, Dagong; Chao, Jing; Li, Shuai; Zhang, Hongxia; Yan, Yingzhan; Liu, Tiegen; Sun, Ye
2018-04-01
In this paper, we report the design and experimental validation of a novel optical sensor for radial artery pulse measurement based on fiber Bragg grating (FBG) and lever amplification mechanism. Pulse waveform analysis is a diagnostic tool for clinical examination and disease diagnosis. High fidelity radial artery pulse waveform has been investigated in clinical studies for estimating central aortic pressure, which is proved to be predictors of cardiovascular diseases. As a three-dimensional cylinder, the radial artery needs to be examined from different locations to achieve optimal pulse waveform for estimation and diagnosis. The proposed optical sensing system is featured as high sensitivity and immunity to electromagnetic interference for multilocation radial artery pulse waveform measurement. The FBG sensor can achieve the sensitivity of 8.236 nm/N, which is comparable to a commonly used electrical sensor. This FBG-based system can provide high accurate measurement, and the key characteristic parameters can be then extracted from the raw signals for clinical applications. The detecting performance is validated through experiments guided by physicians. In the experimental validation, we applied this sensor to measure the pulse waveforms at various positions and depths of the radial artery in the wrist according to the diagnostic requirements. The results demonstrate the high feasibility of using optical systems for physiological measurement and using this FBG sensor for radial artery pulse waveform in clinical applications.
21 CFR 864.7340 - Fibrinogen determination system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... disseminated intravascular coagulation (nonlocalized clotting within the blood vessels) and primary fibrinolysis (the dissolution of fibrin in a blood clot). (b) Classification. Class II (performance standards...
21 CFR 864.7340 - Fibrinogen determination system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... disseminated intravascular coagulation (nonlocalized clotting within the blood vessels) and primary fibrinolysis (the dissolution of fibrin in a blood clot). (b) Classification. Class II (performance standards...
21 CFR 864.7340 - Fibrinogen determination system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... disseminated intravascular coagulation (nonlocalized clotting within the blood vessels) and primary fibrinolysis (the dissolution of fibrin in a blood clot). (b) Classification. Class II (performance standards...
21 CFR 864.7340 - Fibrinogen determination system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... disseminated intravascular coagulation (nonlocalized clotting within the blood vessels) and primary fibrinolysis (the dissolution of fibrin in a blood clot). (b) Classification. Class II (performance standards...
21 CFR 864.7340 - Fibrinogen determination system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... disseminated intravascular coagulation (nonlocalized clotting within the blood vessels) and primary fibrinolysis (the dissolution of fibrin in a blood clot). (b) Classification. Class II (performance standards...
Seismic facies analysis based on self-organizing map and empirical mode decomposition
NASA Astrophysics Data System (ADS)
Du, Hao-kun; Cao, Jun-xing; Xue, Ya-juan; Wang, Xing-jian
2015-01-01
Seismic facies analysis plays an important role in seismic interpretation and reservoir model building by offering an effective way to identify the changes in geofacies inter wells. The selections of input seismic attributes and their time window have an obvious effect on the validity of classification and require iterative experimentation and prior knowledge. In general, it is sensitive to noise when waveform serves as the input data to cluster analysis, especially with a narrow window. To conquer this limitation, the Empirical Mode Decomposition (EMD) method is introduced into waveform classification based on SOM. We first de-noise the seismic data using EMD and then cluster the data using 1D grid SOM. The main advantages of this method are resolution enhancement and noise reduction. 3D seismic data from the western Sichuan basin, China, are collected for validation. The application results show that seismic facies analysis can be improved and better help the interpretation. The powerful tolerance for noise makes the proposed method to be a better seismic facies analysis tool than classical 1D grid SOM method, especially for waveform cluster with a narrow window.
Kwon, Min-Yong; Kim, Chang-Hyun; Lee, Chang-Young
2016-09-01
The aim of this study is to analyze the differences in the incidence, predicting factors, and clinical course of chronic subdural hematoma (CSDH) following surgical clipping between unruptured (UIA) and ruptured intracranial aneurysm (RIA). We conducted a retrospective analysis of 752 patients (UIA : 368 and RIA : 384) who underwent surgical clipping during 8 years. The incidence and predicting factors of CSDH development in the UIA and RIA were compared according to medical records and radiological data. The incidence of postoperative CSDH was higher in the UIA (10.9%) than in the RIA (3.1%) (p=0.000). In multivariate analysis, a high Hounsfield (HF) unit (blood clots) for subdural fluid collection (SFC), persistence of SFC ≥5 mm and male sex in the UIA and A high HF unit for SFC and SFC ≥5 mm without progression to hydrocephalus in the RIA were identified as the independent predicting factors for CSDH development (p<0.05). There were differences in the incidence and predicting factors for CSDH following surgical clipping between UIA and RIA. Blood clots in the subdural space and persistence of SFC ≥5 mm were predicting factors in both UIA and RIA. However, progression to hydrocephalus may have in part contributed to low CSDH development in the RIA. We suggest that cleaning of blood clots in the subdural space and efforts to minimize SFC ≥5 mm at the end of surgery is helpful to prevent CSDH following aneurysmal clipping.
Lounes, K C; Soria, C; Valognes, A; Turchini, M F; Soria, J; Koopman, J
1999-12-01
A new congenital dysfibrinogen, Fibrinogen Bastia, was discovered in a 20-year-old woman with no clinical symptoms. The plasma thrombin-clotting time was severely prolonged. The functional plasma fibrinogen concentration was low (0.2 mg/ml), whereas the immunological concentration was normal (2.9 mg/ml). Purified fibrinogen Bastia displayed a markedly prolonged thrombin-clotting time related to a delayed thrombin-induced fibrin polymerization. Both the thrombin-clotting time and the fibrin polymerization were partially corrected by the addition of calcium ions. The anomaly of fibrinogen Bastia was found to be located in the gamma-chain since by SDS-PAGE performed according to the method of Laemmli two gamma-chains were detected, one normal and one with an apparently lower molecular weight. Furthermore, analysis of plasmin degradation products demonstrated that calcium ions only partially protect fibrinogen Bastia gamma-chain against plasmin digestion, suggesting that the anomaly is located in the C-terminal part of the gamma-chain. Sequence analysis of PCR-amplified genomic DNA fragments of the propositus demonstrated a single base substitution (G-->T) in the exon VIII of the gamma chain gene, resulting in the amino acid substitution 318 Asp (GAC)-->Tyr (TAC). The PCR clones were recloned and 50% of them contained the mutation, indicating that the patient was heterozygous. These data indicate that residue Asp 318 is important for normal fibrin polymerization and the protective effect of calcium ions against plasmin degradation of the C-terminal part of the gamma-chain.
Intermediate-mass-ratio black-hole binaries: numerical relativity meets perturbation theory.
Lousto, Carlos O; Nakano, Hiroyuki; Zlochower, Yosef; Campanelli, Manuela
2010-05-28
We study black-hole binaries in the intermediate-mass-ratio regime 0.01≲q≲0.1 with a new technique that makes use of nonlinear numerical trajectories and efficient perturbative evolutions to compute waveforms at large radii for the leading and nonleading (ℓ, m) modes. As a proof-of-concept, we compute waveforms for q=1/10. We discuss applications of these techniques for LIGO and VIRGO data analysis and the possibility that our technique can be extended to produce accurate waveform templates from a modest number of fully nonlinear numerical simulations.
Sheffield, William P; Eltringham-Smith, Louise J
2011-12-20
The transglutaminase activated factor XIII (FXIIIa) acts to strengthen pathological fibrin clots and to slow their dissolution, in part by crosslinking active α(2)-antiplasmin (α(2)AP) to fibrin. We previously reported that a yeast-derived recombinant fusion protein comprising α(2)AP residues 13-42 linked to human serum albumin (HSA) weakened in vitro clots but failed to become specifically incorporated into in vivo clots. In this study, our aims were to improve both the stability and clot localization of the HSA fusion protein by replacing α(2)AP residues 13-42 with shorter sequences recognized more effectively by FXIIIa. Expression plasmids were prepared encoding recombinant HSA with the following N-terminal 23 residue extensions: H(6)NQEQVSPLTLLAG(4)Y (designated XL1); H(6)DQMMLPWAVTLG(4)Y (XL2); H(6)WQHKIDLPYNGAG(4)Y (XL3); and their 17 residue non-His-tagged equivalents (XL4, XL5, and XL6). The HSA moiety of XL4- to XL6-HSA proteins was C-terminally His-tagged. All chimerae were efficiently secreted from transformed Pichia pastoris yeast except XL3-HSA, and following nickel chelate affinity purification were found to be intact by amino acid sequencing, as was an N-terminally His-tagged version of α(2)AP(13-42)-HSA. Of the proteins tested, XL5-HSA was cross-linked to biotin pentylamine (BPA) most rapidly by FXIIIa, and was the most effective competitor of α(2)AP crosslinking not only to BPA but also to plasma fibrin clots. In the mouse ferric chloride vena cava thrombosis model, radiolabeled XL5-HSA was retained in the clot to a greater extent than recombinant HSA. In the rabbit jugular vein stasis thrombosis model, XL5-HSA was also retained in the clot, in a urea-insensitive manner indicative of crosslinking to fibrin, to a greater extent than recombinant HSA. Fusion protein XL5-HSA (DQMMLPWAVTLG4Y-HSAH6) was found to be more active as a substrate for FXIIIa-mediated transamidation than seven other candidate fusion proteins in vitro. The improved stability and reactivity of this chimeric protein was further evidenced by its incorporation into in vivo clots formed in thrombosis models in both mice and rabbits.
Arora, Aditya; Kothari, Anjaney; Katti, Dhirendra S
2016-12-01
Matrix stiffness is known to play a pivotal role in cellular differentiation. Studies have shown that soft scaffolds (<2-3kPa) promote cellular aggregation and chondrogenesis, whereas, stiffer ones (>10kPa) show poor chondrogenesis in vitro. In this work we investigated if fibrin matrix from clotted blood can act as a soft surrogate which nullifies the influence of the underlying stiff scaffold, thus promoting chondrogenesis irrespective of bulk scale scaffold stiffness. For this we performed in vitro chondrogenesis on soft (∼1.5kPa) and stiff (∼40kPa) gelatin scaffolds in the presence and absence of pericellular plasma clot. Our results demonstrated that in absence of pericellular plasma clot, chondrocytes showed efficient condensation and cartilaginous matrix secretion only on soft scaffolds, whereas, in presence of pericellular plasma clot, cell rounding and cartilaginous matrix secretion was observed in both soft and stiff scaffolds. More specifically, significantly higher collagen II, chondroitin sulfate and aggrecan deposition was observed in soft scaffolds, and soft and stiff scaffolds with pericellular plasma clot as compared to stiff scaffolds without pericellular plasma clot. Moreover, collagen type I, a fibrocartilage/bone marker was significantly higher only in stiff scaffolds without plasma clot. Therefore, it can be concluded that chondrocytes surrounded by a soft fibrin network were unable to sense the stiffness of the underlying scaffold/substrate and hence facilitate chondrogenesis even on stiff scaffolds. This understanding can have significant implications in the design of scaffolds for cartilage tissue engineering. Cell fate is influenced by the mechanical properties of cell culture substrates. Outside the body, cartilage progenitor cells express significant amounts of cartilage-specific markers on soft scaffolds but not on stiff scaffolds. However, when implanted in joints, stiff scaffolds show equivalent expression of markers as seen in soft scaffolds. This disparity in existing literature prompted our study. Our results suggest that encapsulation of cells in a soft plasma clot, present in any surgical intervention, prevents their perception of stiffness of the underlying scaffold, and hence the ability to distinguish between soft and stiff scaffolds vanishes. This finding would aid the design of new scaffolds that elicit cartilage-like biochemical properties while simultaneously being mechanically comparable to cartilage tissue. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Mergers of Non-spinning Black-hole Binaries: Gravitational Radiation Characteristics
NASA Technical Reports Server (NTRS)
Baker, John G.; Boggs, William D.; Centrella, Joan; Kelly, Bernard J.; McWilliams, Sean T.; vanMeter, James R.
2008-01-01
We present a detailed descriptive analysis of the gravitational radiation from black-hole binary mergers of non-spinning black holes, based on numerical simulations of systems varying from equal-mass to a 6:1 mass ratio. Our primary goal is to present relatively complete information about the waveforms, including all the leading multipolar components, to interested researchers. In our analysis, we pursue the simplest physical description of the dominant features in the radiation, providing an interpretation of the waveforms in terms of an implicit rotating source. This interpretation applies uniformly to the full wavetrain, from inspiral through ringdown. We emphasize strong relationships among the l = m modes that persist through the full wavetrain. Exploring the structure of the waveforms in more detail, we conduct detailed analytic fitting of the late-time frequency evolution, identifying a key quantitative feature shared by the l = m modes among all mass-ratios. We identify relationships, with a simple interpretation in terms of the implicit rotating source, among the evolution of frequency and amplitude, which hold for the late-time radiation. These detailed relationships provide sufficient information about the late-time radiation to yield a predictive model for the late-time waveforms, an alternative to the common practice of modeling by a sum of quasinormal mode overtones. We demonstrate an application of this in a new effective-one-body-based analytic waveform model.
Mergers of nonspinning black-hole binaries: Gravitational radiation characteristics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, John G.; Centrella, Joan; Kelly, Bernard J.
2008-08-15
We present a detailed descriptive analysis of the gravitational radiation from black-hole binary mergers of nonspinning black holes, based on numerical simulations of systems varying from equal mass to a 6 ratio 1 mass ratio. Our primary goal is to present relatively complete information about the waveforms, including all the leading multipolar components, to interested researchers. In our analysis, we pursue the simplest physical description of the dominant features in the radiation, providing an interpretation of the waveforms in terms of an implicit rotating source. This interpretation applies uniformly to the full wave train, from inspiral through ringdown. We emphasizemore » strong relationships among the l=m modes that persist through the full wave train. Exploring the structure of the waveforms in more detail, we conduct detailed analytic fitting of the late-time frequency evolution, identifying a key quantitative feature shared by the l=m modes among all mass ratios. We identify relationships, with a simple interpretation in terms of the implicit rotating source, among the evolution of frequency and amplitude, which hold for the late-time radiation. These detailed relationships provide sufficient information about the late-time radiation to yield a predictive model for the late-time waveforms, an alternative to the common practice of modeling by a sum of quasinormal mode overtones. We demonstrate an application of this in a new effective-one-body-based analytic waveform model.« less
Tree species classification in subtropical forests using small-footprint full-waveform LiDAR data
NASA Astrophysics Data System (ADS)
Cao, Lin; Coops, Nicholas C.; Innes, John L.; Dai, Jinsong; Ruan, Honghua; She, Guanghui
2016-07-01
The accurate classification of tree species is critical for the management of forest ecosystems, particularly subtropical forests, which are highly diverse and complex ecosystems. While airborne Light Detection and Ranging (LiDAR) technology offers significant potential to estimate forest structural attributes, the capacity of this new tool to classify species is less well known. In this research, full-waveform metrics were extracted by a voxel-based composite waveform approach and examined with a Random Forests classifier to discriminate six subtropical tree species (i.e., Masson pine (Pinus massoniana Lamb.)), Chinese fir (Cunninghamia lanceolata (Lamb.) Hook.), Slash pines (Pinus elliottii Engelm.), Sawtooth oak (Quercus acutissima Carruth.) and Chinese holly (Ilex chinensis Sims.) at three levels of discrimination. As part of the analysis, the optimal voxel size for modelling the composite waveforms was investigated, the most important predictor metrics for species classification assessed and the effect of scan angle on species discrimination examined. Results demonstrate that all tree species were classified with relatively high accuracy (68.6% for six classes, 75.8% for four main species and 86.2% for conifers and broadleaved trees). Full-waveform metrics (based on height of median energy, waveform distance and number of waveform peaks) demonstrated high classification importance and were stable among various voxel sizes. The results also suggest that the voxel based approach can alleviate some of the issues associated with large scan angles. In summary, the results indicate that full-waveform LIDAR data have significant potential for tree species classification in the subtropical forests.
Pro blood clotting activity of Scoparia dulcis in rats
Ediriweera, E. R. H. S. S.; Jayakody, J. R. A. C.; Ratnasooriya, W. D.
2011-01-01
Scoparia dulcis Linn (Family: Scrophulariaceae, Sinhala: WalKoththamalli) is a perennial herb growing in many tropical countries including Sri Lanka. Traditional Physicians in rural down south areas apply crushed S. dulcis plant on cuts and bruises to stop bleeding. S. dulcis may also have Rakta Sthambhana property. The study on effect of decoction (water extract) of S. dulcis on blood clotting time in rats was carried out to investigate this. Two groups of rats, 12 males and 42 females were used in this experimental study. Forty-two female rats were assigned into seven equal groups (n = 6/gp). Different doses of DE (25, 50, 100, 1000, 1500 mg/kg) (group 1-5) or 2 ml of distilled water (DW) (group 6) were orally administered. 0.1 ml of vitamin K was injected intramuscularly (group 7) as reference drug to seventh the group. Twelve male rats were assigned into two equal groups (n = 6/gp), 2 ml of distilled water (DW) and doses of DE (1500 mg/kg) were orally administered. Clotting time was determined on the Days 1, 2, and 7 using Lee and White method. In the DE treated groups with all doses, there was no reduction in clotting time on the Day 1 but a significant reduction of clotting time (P < 0.05) was observed on the Days 2 and 7. In the group treated with vitamin K, there was no significant reduction in clotting time on Day 1 or 2, but there was a significant reduction in clotting time on Day 7. It is concluded that S. dulcis has proclotting activity (rakthasthambhana property) and this was faster than vitamin K. PMID:22408315
Pro blood clotting activity of Scoparia dulcis in rats.
Ediriweera, E R H S S; Jayakody, J R A C; Ratnasooriya, W D
2011-04-01
Scoparia dulcis Linn (Family: Scrophulariaceae, Sinhala: WalKoththamalli) is a perennial herb growing in many tropical countries including Sri Lanka. Traditional Physicians in rural down south areas apply crushed S. dulcis plant on cuts and bruises to stop bleeding. S. dulcis may also have Rakta Sthambhana property. The study on effect of decoction (water extract) of S. dulcis on blood clotting time in rats was carried out to investigate this. Two groups of rats, 12 males and 42 females were used in this experimental study. Forty-two female rats were assigned into seven equal groups (n = 6/gp). Different doses of DE (25, 50, 100, 1000, 1500 mg/kg) (group 1-5) or 2 ml of distilled water (DW) (group 6) were orally administered. 0.1 ml of vitamin K was injected intramuscularly (group 7) as reference drug to seventh the group. Twelve male rats were assigned into two equal groups (n = 6/gp), 2 ml of distilled water (DW) and doses of DE (1500 mg/kg) were orally administered. Clotting time was determined on the Days 1, 2, and 7 using Lee and White method. In the DE treated groups with all doses, there was no reduction in clotting time on the Day 1 but a significant reduction of clotting time (P < 0.05) was observed on the Days 2 and 7. In the group treated with vitamin K, there was no significant reduction in clotting time on Day 1 or 2, but there was a significant reduction in clotting time on Day 7. It is concluded that S. dulcis has proclotting activity (rakthasthambhana property) and this was faster than vitamin K.
Identification and characterization of α1 -antitrypsin in fibrin clots.
Talens, S; Malfliet, J J M C; van Hal, P Th W; Leebeek, F W G; Rijken, D C
2013-07-01
Preliminary studies indicated that α1 -antitrypsin (A1AT) is the most abundant protein that is non-covalently bound to fibrin clots prepared from plasma. The aim of this study was to identify and characterize fibrin(ogen)-bound A1AT. Plasma clots were prepared and extensively washed with saline. Clot-bound A1AT could only be extracted using denaturing agents such as urea, thiourea or SDS, pointing to an apparently strong association. Purified fibrinogen, but still containing A1AT as a contaminant, was gel filtered, which showed that the A1AT was bound to fibrinogen. A specific ELISA detected the presence of A1AT-fibrinogen complexes in both purified fibrinogen and pooled normal plasma. Finally, fibrin(ogen)-Sepharose chromatography indicated that A1AT purified from plasma contained a small fraction of fibrin(ogen)-binding A1AT. To study the inhibitory activity of fibrin(ogen)-bound A1AT, both fibrinogen containing A1AT and washed plasma clots were incubated with increasing amounts of elastase. SDS-PAGE and Western blotting showed under both conditions the generation of the A1AT-elastase complex as well as cleaved A1AT. The inhibitory activity of fibrin(ogen)-bound A1AT was also demonstrated by measuring elastase-induced lysis of fibrin clots. Fibrin clots contain strongly bound A1AT, which is functionally active as a serine protease inhibitor (serpin). This A1AT might play a role in the local regulation of proteases involved in coagulation or fibrinolysis and represent a novel link between the inflammatory and hemostatic systems. © 2013 International Society on Thrombosis and Haemostasis.
Jiménez-Aristizabal, Román F; López, Catalina; Álvarez, María E; Giraldo, Carlos; Prades, Marta; Carmona, Jorge U
2017-09-01
To compare the temporal release (over three weeks) of tumor necrosis factor alpha (TNF-α), interleukin 4 (IL-4), IL-1 receptor antagonist (IL-1ra), platelet-derived growth factor BB (PDGF-BB) and transforming growth factor beta-1 (TGF-β 1 ) from two platelet-rich fibrin (PRF) preparations from equine blood obtained at either 240g/8min or 416g/10min. Whole blood from 10 horses was used to obtain PRF clots by two different centrifugation protocols. After 1h of rest, PRF clots were deposited in wells with culture medium, which was changed at 6h, 24h and then every 48h to 21days. Cytokines and GFs were measured by ELISA at 1h (serum supernatants from PRF clots) and all time points of culture medium change. A negative control (plasma) and a positive control (blood lysate) were also included. There were no relevant differences between the two protocols for the temporal release of proteins. However, a significant (p=0.01) effect of time was noted. All cytokines were detected after 6h of PRF clot culture until day 21. GF were detected at 1h until day 21. The concentrations for these proteins diminished gradually over time. A highly significant (p=0.01) correlation was noticed between all the proteins evaluated. Leukocytes enmeshed in PRF clots were able to produce cytokines, TGF-β 1 and PDGF-BB. These findings demonstrate a paramount role of leukocytes in wound healing induced or modified by PRF clots in mammals. Copyright © 2017 Elsevier Ltd. All rights reserved.
Temperature affects thrombolytic efficacy using rt-PA and eptifibatide, an in vitro study.
Meunier, Jason M; Chang, Wan-Tsu W; Bluett, Brent; Wenker, Evan; Lindsell, Christopher J; Shaw, George J
2012-09-01
The potential for hypothermia as a neuroprotectant during stroke has led to its increase in clinical use. At the same time, combination pharmaceutical therapies for ischemic stroke using recombinant tissue plasminogen activator (rt-PA), and GP IIb-IIIa inhibitors, such as Eptifibatide (Epf ), are under study. However, there is little data on how the reactions triggered by these agents are impacted by temperature. Here, clot lysis during exposure to the combination of rt-PA and Epf is measured in an in vitro human clot model at hypothermic temperatures. The hypothesis is that lytic efficacy of rt-PA and Epf decreases with decreasing temperature. Whole blood clots from 31 volunteers were exposed to rt-PA (0.5 μg/mL) and Epf (0.63 μg/mL) in human fresh-frozen plasma (rt-PA+Epf ), rt-PA alone in plasma (rt-PA Alone), or to plasma alone (Control), at temperatures from 30°C to 37°C, for 30 minutes. Clot lysis was measured using a microscopic imaging technique; the mean fractional clot loss (FCL) at 30 minutes was used to determine lytic efficacy. Temperature had a significant impact on FCL in clots exposed to rt-PA+Epf, with the FCL being lower at 30°C to 36°C than at 37°C. The FCL remained significantly higher for rt-PA+Epf–treated clots than Controls regardless of temperature, with the exception of measurements made at 30°C when no significant differences in the FCL were observed between groups. The use of hypothermia as a neuroprotectant may negatively impact the therapeutic benefit of thrombolytic agents.
Temperature Affects Thrombolytic Efficacy Using rt-PA and Eptifibatide, an In Vitro Study
Chang, Wan-Tsu W.; Bluett, Brent; Wenker, Evan; Lindsell, Christopher J.; Shaw, George J.
2012-01-01
The potential for hypothermia as a neuroprotectant during stroke has led to its increase in clinical use. At the same time, combination pharmaceutical therapies for ischemic stroke using recombinant tissue plasminogen activator (rt-PA), and GP IIb-IIIa inhibitors, such as Eptifibatide (Epf ), are under study. However, there is little data on how the reactions triggered by these agents are impacted by temperature. Here, clot lysis during exposure to the combination of rt-PA and Epf is measured in an in vitro human clot model at hypothermic temperatures. The hypothesis is that lytic efficacy of rt-PA and Epf decreases with decreasing temperature. Whole blood clots from 31 volunteers were exposed to rt-PA (0.5 μg/mL) and Epf (0.63 μg/mL) in human fresh-frozen plasma (rt-PA+Epf ), rt-PA alone in plasma (rt-PA Alone), or to plasma alone (Control), at temperatures from 30°C to 37°C, for 30 minutes. Clot lysis was measured using a microscopic imaging technique; the mean fractional clot loss (FCL) at 30 minutes was used to determine lytic efficacy. Temperature had a significant impact on FCL in clots exposed to rt-PA+Epf, with the FCL being lower at 30°C to 36°C than at 37°C. The FCL remained significantly higher for rt-PA+Epf–treated clots than Controls regardless of temperature, with the exception of measurements made at 30°C when no significant differences in the FCL were observed between groups. The use of hypothermia as a neuroprotectant may negatively impact the therapeutic benefit of thrombolytic agents. PMID:23667777
Zolfagharian, Hossein; Mohajeri, Mohammad; Babaie, Mahdi
2015-12-01
Bee venom (BV) is a complex mixture of proteins and contains proteins such as phospholipase and melittin, which have an effect on blood clotting and blood clots. The mechanism of action of honey bee venom (HBV, Apis mellifera) on human plasma proteins and its anti-thrombotic effect were studied. The purpose of this study was to investigate the anti-coagulation effect of BV and its effects on blood coagulation and purification. Crude venom obtained from Apis mellifera was selected. The anti-coagulation factor of the crude venom from this species was purified by using gel filtration chromatography (sephadex G-50), and the molecular weights of the anti-coagulants in this venom estimated by using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Blood samples were obtained from 10 rabbits, and the prothrombin time (PT) and the partial thromboplastin time (PTT) tests were conducted. The approximate lethal dose (LD) values of BV were determined. Crude BV increased the blood clotting time. For BV concentrations from 1 to 4 mg/mL, clotting was not observed even at more than 300 seconds, standard deviations (SDs) = ± 0.71; however, clotting was observed in the control group 13.8 s, SDs = ± 0.52. Thus, BV can be considered as containing anti-coagulation factors. Crude BV is composed 4 protein bands with molecular weights of 3, 15, 20 and 41 kilodalton (kDa), respectively. The LD50 of the crude BV was found to be 177.8 μg/mouse. BV contains anti-coagulation factors. The fraction extracted from the Iranian bees contains proteins that are similar to anti-coagulation proteins, such as phospholipase A2 (PLA2) and melittin, and that can increase the blood clotting times in vitro.
Zolfagharian, Hossein; Mohajeri, Mohammad; Babaie, Mahdi
2015-01-01
Objectives: Bee venom (BV) is a complex mixture of proteins and contains proteins such as phospholipase and melittin, which have an effect on blood clotting and blood clots. The mechanism of action of honey bee venom (HBV, Apis mellifera) on human plasma proteins and its anti-thrombotic effect were studied. The purpose of this study was to investigate the anti-coagulation effect of BV and its effects on blood coagulation and purification. Methods: Crude venom obtained from Apis mellifera was selected. The anti-coagulation factor of the crude venom from this species was purified by using gel filtration chromatography (sephadex G-50), and the molecular weights of the anti-coagulants in this venom estimated by using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Blood samples were obtained from 10 rabbits, and the prothrombin time (PT) and the partial thromboplastin time (PTT) tests were conducted. The approximate lethal dose (LD) values of BV were determined. Results: Crude BV increased the blood clotting time. For BV concentrations from 1 to 4 mg/mL, clotting was not observed even at more than 300 seconds, standard deviations (SDs) = ± 0.71; however, clotting was observed in the control group 13.8 s, SDs = ± 0.52. Thus, BV can be considered as containing anti-coagulation factors. Crude BV is composed 4 protein bands with molecular weights of 3, 15, 20 and 41 kilodalton (kDa), respectively. The LD50 of the crude BV was found to be 177.8 μg/mouse. Conclusion: BV contains anti-coagulation factors. The fraction extracted from the Iranian bees contains proteins that are similar to anti-coagulation proteins, such as phospholipase A2 (PLA2) and melittin, and that can increase the blood clotting times in vitro. PMID:26998384
NASA Astrophysics Data System (ADS)
Schumacher, F.; Friederich, W.
2015-12-01
We present the modularized software package ASKI which is a flexible and extendable toolbox for seismic full waveform inversion (FWI) as well as sensitivity or resolution analysis operating on the sensitivity matrix. It utilizes established wave propagation codes for solving the forward problem and offers an alternative to the monolithic, unflexible and hard-to-modify codes that have typically been written for solving inverse problems. It is available under the GPL at www.rub.de/aski. The Gauss-Newton FWI method for 3D-heterogeneous elastic earth models is based on waveform sensitivity kernels and can be applied to inverse problems at various spatial scales in both Cartesian and spherical geometries. The kernels are derived in the frequency domain from Born scattering theory as the Fréchet derivatives of linearized full waveform data functionals, quantifying the influence of elastic earth model parameters on the particular waveform data values. As an important innovation, we keep two independent spatial descriptions of the earth model - one for solving the forward problem and one representing the inverted model updates. Thereby we account for the independent needs of spatial model resolution of forward and inverse problem, respectively. Due to pre-integration of the kernels over the (in general much coarser) inversion grid, storage requirements for the sensitivity kernels are dramatically reduced.ASKI can be flexibly extended to other forward codes by providing it with specific interface routines that contain knowledge about forward code-specific file formats and auxiliary information provided by the new forward code. In order to sustain flexibility, the ASKI tools must communicate via file output/input, thus large storage capacities need to be accessible in a convenient way. Storing the complete sensitivity matrix to file, however, permits the scientist full manual control over each step in a customized procedure of sensitivity/resolution analysis and full waveform inversion.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.
Kasahara, Kohji; Kaneda, Mizuho; Miki, Toshiaki; Iida, Kazuko; Sekino-Suzuki, Naoko; Kawashima, Ikuo; Suzuki, Hidenori; Shimonaka, Motoyuki; Arai, Morio; Ohno-Iwashita, Yoshiko; Kojima, Soichi; Abe, Mitsuhiro; Kobayashi, Toshihide; Okazaki, Toshiro; Souri, Masayoshi; Ichinose, Akitada; Yamamoto, Naomasa
2013-11-07
Membrane rafts are spatially and functionally heterogenous in the cell membrane. We observed that lysenin-positive sphingomyelin (SM)-rich rafts are identified histochemically in the central region of adhered platelets where fibrin and myosin are colocalized on activation by thrombin. The clot retraction of SM-depleted platelets from SM synthase knockout mouse was delayed significantly, suggesting that platelet SM-rich rafts are involved in clot retraction. We found that fibrin converted by thrombin translocated immediately in platelet detergent-resistant membrane (DRM) rafts but that from Glanzmann's thrombasthenic platelets failed. The fibrinogen γ-chain C-terminal (residues 144-411) fusion protein translocated to platelet DRM rafts on thrombin activation, but its mutant that was replaced by A398A399 at factor XIII crosslinking sites (Q398Q399) was inhibited. Furthermore, fibrin translocation to DRM rafts was impaired in factor XIII A subunit-deficient mouse platelets, which show impaired clot retraction. In the cytoplasm, myosin translocated concomitantly with fibrin translocation into the DRM raft of thrombin-stimulated platelets. Furthermore, the disruption of SM-rich rafts by methyl-β-cyclodextrin impaired myosin activation and clot retraction. Thus, we propose that clot retraction takes place in SM-rich rafts where a fibrin-αIIbβ3-myosin complex is formed as a primary axis to promote platelet contraction.
Thromboelastography Values in Hispaniolan Amazon Parrots ( Amazona ventralis ): A Pilot Study.
Keller, Krista A; Sanchez-Migallon Guzman, David; Acierno, Mark J; Beaufrère, Hugues; Sinclair, Kristin M; Owens, Sean D; Paul-Murphy, Joanne; Tully, Thomas N
2015-09-01
Thromboelastography (TEG) provides a global assessment of coagulation, including the rate of clot initiation, clot kinetics, achievement of maximum clot strength, and fibrinolysis. Thromboelastography (TEG) is used with increasing frequency in the field of veterinary medicine, although its usefulness in avian species has not been adequately explored. The purpose of this preliminary study was to assess the applicability of TEG in psittacine birds. Kaolin-activated TEG was used to analyze citrated whole blood collected routinely from 8 healthy adult Hispaniolan Amazon parrots ( Amazona ventralis ). The minimum and maximum TEG values obtained included time to clot initiation (2.6-15 minutes), clot formation time (4.3-20.8 minutes), α angle (12.7°-47.9°), maximum amplitude of clot strength (26.3-46.2 mm), and percentage of lysis 30 minutes after achievement of maximum amplitude (0%-5.3%). The TEG values demonstrated comparative hypocoagulability relative to published values in canine and feline species. Differences may be explained by either the in vitro temperature at which TEG is standardly performed or the method of activation used in this study. Although TEG may have significant advantages over traditional coagulation tests, including lack of need for species-specific reagents, further evaluation is required in a variety of avian species and while exploring various TEG methodologies before this technology can be recommended for use in clinical cases.
Watanabe, Taisuke; Isobe, Kazushige; Suzuki, Taiji; Kawabata, Hideo; Nakamura, Masayuki; Tsukioka, Tsuneyuki; Okudera, Toshimitsu; Okudera, Hajime; Uematsu, Kohya; Okuda, Kazuhiro; Nakata, Koh; Kawase, Tomoyuki
2017-01-01
Platelet concentrates should be quality-assured of purity and identity prior to clinical use. Unlike for the liquid form of platelet-rich plasma, platelet counts cannot be directly determined in solid fibrin clots and are instead calculated by subtracting the counts in other liquid or semi-clotted fractions from those in whole blood samples. Having long suspected the validity of this method, we herein examined the possible loss of platelets in the preparation process. Blood samples collected from healthy male donors were immediately centrifuged for advanced platelet-rich fibrin (A-PRF) and concentrated growth factors (CGF) according to recommended centrifugal protocols. Blood cells in liquid and semi-clotted fractions were directly counted. Platelets aggregated on clot surfaces were observed by scanning electron microscopy. A higher centrifugal force increased the numbers of platelets and platelet aggregates in the liquid red blood cell fraction and the semi-clotted red thrombus in the presence and absence of the anticoagulant, respectively. Nevertheless, the calculated platelet counts in A-PRF/CGF preparations were much higher than expected, rendering the currently accepted subtraction method inaccurate for determining platelet counts in fibrin clots. To ensure the quality of solid types of platelet concentrates chairside in a timely manner, a simple and accurate platelet-counting method should be developed immediately. PMID:29563413
Ultrasound active nanoscaled lipid formulations for thrombus lysis.
Becker, Andreas; Marxer, Elena; Brüssler, Jana; Hoormann, Anne Sophia; Kuhnt, Daniela; Bakowsky, Udo; Nimsky, Christopher
2011-04-01
In the present study, we investigated the sonothrombolytic effect of new nanoscaled lipid formulations in human blood clots, using diagnostic ultrasound. Human blood clots of 1 ml were incubated with 1 μl of the different lipid dispersions DPPC/CH, DPPC/PEG40S, DSPC/PEG40S and the commercially available ultrasound contrast agent SonoVue®. Clots were stored for 3 days at 5 °C to obtain maximal clot retraction and lytic resistance. Each clot weight was determined before and after continuous insonation for 1h of insonation at 1.4 MHz. The pressure in the insonation chamber was 80 mm Hg to mimic middle arterial blood pressure. There were no significant differences in thrombus weight before insonation. All nanoscaled formulations and SonoVue® were able to reduce thrombus weight compared to the weight loss of clots that were not insonated but kept under pressure for one hour (p < 0.001). We found a highly significant weight reduction with DSPC/PEG40S compared to SonoVue® (p = 0.007). Nanoscaled DSPC/PEG40S dispersion could be a promising formulation in ultrasound enhanced thrombolysis even without thrombolytic drugs. Stable cavitation is a crucial parameter in fragmentation of thrombus architecture. Further studies of physicochemical properties of DSPC/PEG40S are necessary to corroborate our hypothesis. Copyright © 2010 Elsevier B.V. All rights reserved.
Kobayashi, Kazuyoshi; Imagama, Shiro; Ito, Zenya; Ando, Kei; Hida, Tetsuro; Ito, Kenyu; Tsushima, Mikito; Ishikawa, Yoshimoto; Matsumoto, Akiyuki; Nishida, Yoshihiro; Ishiguro, Naoki
2017-01-01
OBJECTIVE Corrective surgery for spinal deformities can lead to neurological complications. Several reports have described spinal cord monitoring in surgery for spinal deformity, but only a few have included patients younger than 20 years with adolescent idiopathic scoliosis (AIS). The goal of this study was to evaluate the characteristics of cases with intraoperative transcranial motor evoked potential (Tc-MEP) waveform deterioration during posterior corrective fusion for AIS. METHODS A prospective database was reviewed, comprising 68 patients with AIS who were treated with posterior corrective fusion in a prospective database. A total of 864 muscles in the lower extremities were chosen for monitoring, and acceptable baseline responses were obtained from 819 muscles (95%). Intraoperative Tc-MEP waveform deterioration was defined as a decrease in intraoperative amplitude of ≥ 70% of the control waveform. Age, Cobb angle, flexibility, operative time, estimated blood loss (EBL), intraoperative body temperature, blood pressure, number of levels fused, and correction rate were examined in patients with and without waveform deterioration. RESULTS The patients (3 males and 65 females) had an average age of 14.4 years (range 11-19 years). The mean Cobb angles before and after surgery were 52.9° and 11.9°, respectively, giving a correction rate of 77.4%. Fourteen patients (20%) exhibited an intraoperative waveform change, and these occurred during incision (14%), after screw fixation (7%), during the rotation maneuver (64%), during placement of the second rod after the rotation maneuver (7%), and after intervertebral compression (7%). Most waveform changes recovered after decreased correction or rest. No patient had a motor deficit postoperatively. In multivariate analysis, EBL (OR 1.001, p = 0.085) and number of levels fused (OR 1.535, p = 0.045) were associated with waveform deterioration. CONCLUSIONS Waveform deterioration commonly occurred during rotation maneuvers and more frequently in patients with a larger preoperative Cobb angle. The significant relationships of EBL and number of levels fused with waveform deterioration suggest that these surgical invasions may be involved in waveform deterioration.
An Investigation of High Intensity Focused Ultrasound Thrombolysis
NASA Astrophysics Data System (ADS)
Wright, Cameron; Hynynen, Kullervo; Goertz, David
2011-09-01
Investigations into high intensity focused ultrasound (HIFU) thrombolysis in vitro and in vivo in a rabbit femoral artery thrombus model were performed. A 1.51 MHz focused transducer was used to treat clots with pulse lengths of 1-10 ms, acoustic powers of 1-300 W and exposure durations of 5-20 s. Our measurements indicate the creation of acoustic radiation force induced clot displacements are insufficient to mechanically fractionate clots, despite reaching displacements >100 μm. Only under the presence of inertial cavitation was HIFU able to disrupt clots. Cavitation thresholds of 160 W in vitro and 215 W in vivo were observed. In vitro, clots insonified at powers above the cavitation threshold eroded regions up to 2.5× the transducer beam width. Successful recanalization in vivo occurred in 5/20 cases for 1ms pulses at powers >215 W. 10 ms pulses created high incidences of symptomatic bleeding while 1 ms pulses did not. These results demonstrate treatment feasibility in vivo, although further work is required to understand the influence of different acoustic parameters on treatment outcome.
Auboire, Laurent; Escoffre, Jean-Michel; Fouan, Damien; Jacquet, Jean-René; Ossant, Frédéric; Grégoire, Jean-Marc; Bouakaz, Ayache
2017-07-24
Thrombosis is a major cause of several diseases, i.e. myocardial infarction, cerebral stroke and pulmonary embolism. Thrombolytic therapies are required to induce fast and efficient recanalization of occluded vessels. To evaluate the in vitro efficacy of these thrombolytic strategies, measuring clot dissolution is essential. This study aimed to evaluate and validate high resolution ultrasound as a tool to assess the exact volume of clots in 3D and in real time during in vitro thrombolytic drug testing. This new method was validated by measuring the effects of concentration range of recombinant tissue type plasminogen activator on a blood clot during complete occlusion or 70% stenosis of a vessel. This study shows that high resolution ultrasound imaging allows for a real-time assessment of the 3D volume of a blood clot with negligible inter- and intra-operator variabilities. The conclusions drawn from this study demonstrate the promising potential of high resolution ultrasound imaging for the in vitro assessment of new thrombolytic drugs.
Na, H S; Chung, Y H; Hwang, J W; Do, S H
2012-08-01
We investigated the effects of magnesium sulphate on blood coagulation profiles using rotational thromboelastometry in gynaecological patients undergoing pelviscopic surgery. Patients were randomly allocated to the magnesium group (n = 20) or control group (n = 20). The magnesium group received magnesium sulphate (50 mg.kg(-1) followed by continuous infusion of 15 mg.kg(-1).h(-1)), whereas the control group received the same volume of isotonic saline according to the same methods. Mean (SD) postoperative serum magnesium levels were 1.58 (0.17) mmol.l(-1) in the magnesium group compared with 0.98 (0.06) mmol.l(-1) in the control group (p < 0.001). Postoperative clotting time, clot formation time, α-angle and maximum clot firmness of INTEM, and clot formation time, α-angle, and maximum clot firmness of EXTEM were significantly different between the two groups (p < 0.05). Intra-operative infusion of magnesium sulphate seems to attenuate postoperative hypercoagulability by maintaining magnesium levels at the upper limit of the normal range. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.
Tumour imaging by the detection of fibrin clots in tumour stroma using an anti-fibrin Fab fragment
Obonai, Toshifumi; Fuchigami, Hirobumi; Furuya, Fumiaki; Kozuka, Naoyuki; Yasunaga, Masahiro; Matsumura, Yasuhiro
2016-01-01
The diagnosis of early and aggressive types of cancer is important for providing effective cancer therapy. Cancer-induced fibrin clots exist only within lesions. Previously, we developed a monoclonal antibody (clone 102-10) that recognizes insoluble fibrin but not fibrinogen or soluble fibrin and confirmed that fibrin clots form continuously in various cancers. Here, we describe the development of a Fab fragment probe of clone 102-10 for tumour imaging. The distribution of 102-10 Fab was investigated in genetically engineered mice bearing pancreatic ductal adenocarcinoma (PDAC), and its effect on blood coagulation was examined. Immunohistochemical and ex vivo imaging revealed that 102-10 Fab was distributed selectively in fibrin clots in PDAC tumours 3 h after injection and that it disappeared from the body after 24 h. 102-10 Fab had no influence on blood coagulation or fibrinolysis. Tumour imaging using anti-fibrin Fab may provide a safe and effective method for the diagnosis of invasive cancers by detecting fibrin clots in tumour stroma. PMID:27009516
Purification and properties of rennin-like enzyme from Aspergillus ochraceus.
Ismail, A A; Foda, M S; Khorshid, M A
1978-01-01
An active milk-clotting enzyme was purified some 40-fold from culture supernatant of Aspergillus ochraceus. The purification steps included ammonium sulfate precipitation, G-100 Sephadex gel filtration, and ion exchange chromatography, using DEAE Cellulose column. The enzyme exhibited milk-clotting activity and proteolytic behaviour, an optimum at pH 6.0 and in the range of 7--8.5, respectively. The purified enzyme was actively proteolytic against casein, haemoglobin, and bovine serum albumin at pH 8. The milk-clotting activity was greatly enhanced by manganous ions and by increasing concentrations of calcium chloride. Copper, zinc, and ammonium ions were potent inhibitors of the milk-curdling activity of the purified enzyme. Significant inhibition was also noted with sodium chloride at concentrations of 3% or more. Under the specified reaction condition, maximum rate of proteolysis against casein was obtained at 0.4% substrate concentration, whereas the milk-clotting time was linear proportional to dry skim milk concentration in the range of 8 to 24%. The results are discussed in comparison with other microbial milk-clotting enzymes, and limitations of applicability are also presented.
... vein thrombosis - D-dimer; Pulmonary embolism - D-dimer; Blood clot to the lungs - D-dimer ... dimer test if you are showing symptoms of blood clots, such as: Swelling, pain, warmth, and changes in ...
... miscarriages or infant deaths. Top of Page Other Concerns Bleeding and Clotting Disorders : Bleeding and clotting disorders ... anyone affected, but pregnant women often have special concerns. Learn more about infections, medications, vaccinations, and toxins ...
... sitting for long periods. If you travel by airplane, walk the aisle periodically. For long car trips, ... Your-Risk-for-Excessive-Blood-Clotting_UCM_448771_Article.jsp. Accessed April 18, 2016. What causes excessive ...
... blood clot to close the lesion or focused irradiation treatment that is designed to damage the blood ... blood clot to close the lesion or focused irradiation treatment that is designed to damage the blood ...
... platelets from sticking together and forming blood clots. Aspirin is the most common type of antiplatelet medicine. ... are recovering from a heart attack are given aspirin to prevent further blood clots from forming in ...
Multifrequency acoustics as a probe of mesoscopic blood coagulation dynamics
NASA Astrophysics Data System (ADS)
Ganesan, Adarsh; Rajendran, Gokulnath; Ercole, Ari; Seshia, Ashwin
2016-08-01
Coagulation is a complex enzymatic polymerisation cascade. Disordered coagulation is common in medicine and may be life-threatening yet clinical assays are typically bulky and/or provide an incomplete picture of clot mechanical evolution. We present the adaptation of an in-plane acoustic wave device: quartz crystal microbalance with dissipation at multiple harmonics to determine the time-evolution of mesoscale mechanical properties of clot formation in vitro. This approach is sensitive to changes in surface and bulk clot structure in various models of induced coagulopathy. Furthermore, we are able to show that clot formation at surfaces has different kinetics and mechanical strength to that in the bulk, which may have implications for the design of bioprosthetic materials. The "Multifrequency acoustics" approach thus enables unique capability to portray biological processes concerning blood coagulation.
Grams, Astrid E; Rehwald, Rafael; Schmittnägel, Charlotte; Schmidt, Thorsten; Tanislav, Christian; Berghoff, Martin; Krombach, Gabriele A; Moritz, Regina; Obert, Martin; Gizewski, Elke R; Glodny, Bernhard
The aim was to identify the factors influencing intracranial vessel density (VD). The Hounsfield units of the dense vessel and the contralateral side were measured in 34 patients with arterial clots, 20 with venous clots, and 196 without clots and correlated with skull thickness, density and dimensions, gender, age, red blood cell count (RBC), hemoglobin (HB), hematocrit (HT), creatinine, and sodium. Positive correlations were found between VD and HT, RBC, HB, creatinine, and occipital bone density. Density differences between the right and left intracranial vessels were more accurate (sensitivity/specificity/accuracy=0.91/0.93/0.93 and 0.75/0.87/0.85, respectively) for detecting clots than VD alone. HT, RBC, and HB are the main factors that correlate with VD. Copyright © 2016 Elsevier Inc. All rights reserved.
Structural properties of fracture haematoma: current status and future clinical implications.
Wang, Xin; Friis, Thor; Glatt, Vaida; Crawford, Ross; Xiao, Yin
2017-10-01
Blood clots (haematomas) that form immediately following a bone fracture have been shown to be vital for the subsequent healing process. During the clotting process, a number of factors can influence the fibrin clot structure, such as fibrin polymerization, growth factor binding, cellular infiltration (including platelet retraction), protein concentrations and cytokines. The modulation of the fibrin clot structure within the fracture site has important clinical implications and could result in the development of multifunctional scaffolds that mimic the natural structure of a haematoma. Artificial haematoma structures such as these can be created from the patient's own blood and can therefore act as an ideal bone defect filling material for potential clinical application to accelerate bone regeneration. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
2010-01-01
Exposure to urban particulate matter has been associated with an increased risk of cardiovascular disease and thrombosis. We studied the effects of transient exposure to diesel particles on fibrin clot structure of 16 healthy individuals (age 21- 44). The subjects were randomly exposed to diesel exhaust and filtered air on two separate occasions. Blood samples were collected before exposure, and 2 and 6 hours after exposure. There were no significant changes on clot permeability, maximum turbidity, lag time, fibre diameter, fibre density and fibrinogen level between samples taken after diesel exhaust exposure and samples taken after filtered air exposure. These data show that there are no prothrombotic changes in fibrin clot structure in young, healthy individuals exposed to diesel exhaust. PMID:20565709
Hoemann, Caroline D; Hurtig, Mark; Rossomacha, Evgeny; Sun, Jun; Chevrier, Anik; Shive, Matthew S; Buschmann, Michael D
2005-12-01
Microfracture is a surgical procedure that is used to treat focal articular cartilage defects. Although joint function improves following microfracture, the procedure elicits incomplete repair. As blood clot formation in the microfracture defect is an essential initiating event in microfracture therapy, we hypothesized that the repair would be improved if the microfracture defect were filled with a blood clot that was stabilized by the incorporation of a thrombogenic and adhesive polymer, specifically, chitosan. The objectives of the present study were to evaluate (1) blood clot adhesion in fresh microfracture defects and (2) the quality of the repair, at six months postoperatively, of microfracture defects that had been treated with or without chitosan-glycerol phosphate/blood clot implants, using a sheep model. In eighteen sheep, two 1-cm2 full-thickness chondral defects were created in the distal part of the femur and treated with microfracture; one defect was made in the medial femoral condyle, and the other defect was made in the trochlea. In four sheep, microfracture defects were created bilaterally; the microfracture defects in one knee received no further treatment, and the microfracture defects in the contralateral knee were filled with chitosan-glycerol phosphate/autologous whole blood and the implants were allowed to solidify. Fresh defects in these four sheep were collected at one hour postoperatively to compare the retention of the chitosan-glycerol phosphate/blood clot with that of the normal clot and to define the histologic characteristics of these fresh defects. In the other fourteen sheep, microfracture defects were made in only one knee and either were left untreated (control group; six sheep) or were treated with chitosan-glycerol phosphate/blood implant (treatment group; eight sheep), and the quality of repair was assessed histologically, histomorphometrically, and biochemically at six months postoperatively. In the defects that were examined one hour postoperatively, chitosan-glycerol phosphate/blood clots showed increased adhesion to the walls of the defects as compared with the blood clots in the untreated microfracture defects. After histological processing, all blood clots in the control microfracture defects had been lost, whereas chitosanglycerol phosphate/blood clot adhered to and was partly retained on the surfaces of the defect. At six months, defects that had been treated with chitosan-glycerol phosphate/blood were filled with significantly more hyaline repair tissue (p < 0.05) compared with control defects. Repair tissue from medial femoral condyle defects that had been treated with chitosan-glycerol phosphate/blood contained more cells and more collagen compared with control defects and showed complete restoration of glycosaminoglycan levels. Solidification of a chitosan-glycerol phosphate/blood implant in microfracture defects improved cartilage repair compared with microfracture alone by increasing the amount of tissue and improving its biochemical composition and cellular organization.
Computational assessment of model-based wave separation using a database of virtual subjects.
Hametner, Bernhard; Schneider, Magdalena; Parragh, Stephanie; Wassertheurer, Siegfried
2017-11-07
The quantification of arterial wave reflection is an important area of interest in arterial pulse wave analysis. It can be achieved by wave separation analysis (WSA) if both the aortic pressure waveform and the aortic flow waveform are known. For better applicability, several mathematical models have been established to estimate aortic flow solely based on pressure waveforms. The aim of this study is to investigate and verify the model-based wave separation of the ARCSolver method on virtual pulse wave measurements. The study is based on an open access virtual database generated via simulations. Seven cardiac and arterial parameters were varied within physiological healthy ranges, leading to a total of 3325 virtual healthy subjects. For assessing the model-based ARCSolver method computationally, this method was used to perform WSA based on the aortic root pressure waveforms of the virtual patients. Asa reference, the values of WSA using both the pressure and flow waveforms provided by the virtual database were taken. The investigated parameters showed a good overall agreement between the model-based method and the reference. Mean differences and standard deviations were -0.05±0.02AU for characteristic impedance, -3.93±1.79mmHg for forward pressure amplitude, 1.37±1.56mmHg for backward pressure amplitude and 12.42±4.88% for reflection magnitude. The results indicate that the mathematical blood flow model of the ARCSolver method is a feasible surrogate for a measured flow waveform and provides a reasonable way to assess arterial wave reflection non-invasively in healthy subjects. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nüesch, Corina; Roos, Elena; Pagenstert, Geert; Mündermann, Annegret
2017-05-24
Inertial sensor systems are becoming increasingly popular for gait analysis because their use is simple and time efficient. This study aimed to compare joint kinematics measured by the inertial sensor system RehaGait® with those of an optoelectronic system (Vicon®) for treadmill walking and running. Additionally, the test re-test repeatability of kinematic waveforms and discrete parameters for the RehaGait® was investigated. Twenty healthy runners participated in this study. Inertial sensors and reflective markers (PlugIn Gait) were attached according to respective guidelines. The two systems were started manually at the same time. Twenty consecutive strides for walking and running were recorded and each software calculated sagittal plane ankle, knee and hip kinematics. Measurements were repeated after 20min. Ensemble means were analyzed calculating coefficients of multiple correlation for waveforms and root mean square errors (RMSE) for waveforms and discrete parameters. After correcting the offset between waveforms, the two systems/models showed good agreement with coefficients of multiple correlation above 0.950 for walking and running. RMSE of the waveforms were below 5° for walking and below 8° for running. RMSE for ranges of motion were between 4° and 9° for walking and running. Repeatability analysis of waveforms showed very good to excellent coefficients of multiple correlation (>0.937) and RMSE of 3° for walking and 3-7° for running. These results indicate that in healthy subjects sagittal plane joint kinematics measured with the RehaGait® are comparable to those using a Vicon® system/model and that the measured kinematics have a good repeatability, especially for walking. Copyright © 2017 Elsevier Ltd. All rights reserved.
... blood to the intestines run directly from the aorta, the main artery from the heart. Hardening of ... clots most often come from the heart or aorta. These clots are more commonly seen in people ...
21 CFR 864.7300 - Fibrin monomer paracoagulation test.
Code of Federal Regulations, 2011 CFR
2011-04-01
... clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II...
... the number of platelets (cells that help the blood clot) to decrease the risk of bleeding in adults ... of the eye that may cause vision problems), blood clots, any condition that increases the risk that you ...
21 CFR 864.7300 - Fibrin monomer paracoagulation test.
Code of Federal Regulations, 2012 CFR
2012-04-01
... clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II...
21 CFR 864.7320 - Fibrinogen/fibrin degradation products assay.
Code of Federal Regulations, 2014 CFR
2014-04-01
... dissolution of the fibrin in a blood clot) and in monitoring therapy for disseminated intravascular coagulation (nonlocalized clotting in the blood vessels). (b) Classification. Class II (performance standards...
21 CFR 864.7300 - Fibrin monomer paracoagulation test.
Code of Federal Regulations, 2010 CFR
2010-04-01
... clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II...
21 CFR 864.7320 - Fibrinogen/fibrin degradation products assay.
Code of Federal Regulations, 2013 CFR
2013-04-01
... dissolution of the fibrin in a blood clot) and in monitoring therapy for disseminated intravascular coagulation (nonlocalized clotting in the blood vessels). (b) Classification. Class II (performance standards...
21 CFR 864.7320 - Fibrinogen/fibrin degradation products assay.
Code of Federal Regulations, 2012 CFR
2012-04-01
... dissolution of the fibrin in a blood clot) and in monitoring therapy for disseminated intravascular coagulation (nonlocalized clotting in the blood vessels). (b) Classification. Class II (performance standards...
21 CFR 864.7300 - Fibrin monomer paracoagulation test.
Code of Federal Regulations, 2014 CFR
2014-04-01
... clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II...
21 CFR 864.7320 - Fibrinogen/fibrin degradation products assay.
Code of Federal Regulations, 2011 CFR
2011-04-01
... dissolution of the fibrin in a blood clot) and in monitoring therapy for disseminated intravascular coagulation (nonlocalized clotting in the blood vessels). (b) Classification. Class II (performance standards...
21 CFR 864.7300 - Fibrin monomer paracoagulation test.
Code of Federal Regulations, 2013 CFR
2013-04-01
... clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II...
... of medication may also prevent new clots from forming. They do not, however, break up existing clots ... to promote blood flow. Anticoagulant therapy lots from forming and diminishes the risk of a pulmonary embolus. ...
... pain. Anti-clotting drugs such as aspirin and clopidogrel (Plavix), ticagrelor (Brilinta) or prasugrel (Effient) can help prevent ... is especially true for anti-clotting drugs (aspirin, clopidogrel, ticagrelor and prasugrel). Your provider may recommend a ...
... A or B may need to have an infusion of clotting factor taken from donated human blood ... for bleeding is serious, a doctor may give infusions of clotting factor to avoid bleeding (preventive infusions) ...
Compression strategies for LiDAR waveform cube
NASA Astrophysics Data System (ADS)
Jóźków, Grzegorz; Toth, Charles; Quirk, Mihaela; Grejner-Brzezinska, Dorota
2015-01-01
Full-waveform LiDAR data (FWD) provide a wealth of information about the shape and materials of the surveyed areas. Unlike discrete data that retains only a few strong returns, FWD generally keeps the whole signal, at all times, regardless of the signal intensity. Hence, FWD will have an increasingly well-deserved role in mapping and beyond, in the much desired classification in the raw data format. Full-waveform systems currently perform only the recording of the waveform data at the acquisition stage; the return extraction is mostly deferred to post-processing. Although the full waveform preserves most of the details of the real data, it presents a serious practical challenge for a wide use: much larger datasets compared to those from the classical discrete return systems. Atop the need for more storage space, the acquisition speed of the FWD may also limit the pulse rate on most systems that cannot store data fast enough, and thus, reduces the perceived system performance. This work introduces a waveform cube model to compress waveforms in selected subsets of the cube, aimed at achieving decreased storage while maintaining the maximum pulse rate of FWD systems. In our experiments, the waveform cube is compressed using classical methods for 2D imagery that are further tested to assess the feasibility of the proposed solution. The spatial distribution of airborne waveform data is irregular; however, the manner of the FWD acquisition allows the organization of the waveforms in a regular 3D structure similar to familiar multi-component imagery, as those of hyper-spectral cubes or 3D volumetric tomography scans. This study presents the performance analysis of several lossy compression methods applied to the LiDAR waveform cube, including JPEG-1, JPEG-2000, and PCA-based techniques. Wide ranges of tests performed on real airborne datasets have demonstrated the benefits of the JPEG-2000 Standard where high compression rates incur fairly small data degradation. In addition, the JPEG-2000 Standard-compliant compression implementation can be fast and, thus, used in real-time systems, as compressed data sequences can be formed progressively during the waveform data collection. We conclude from our experiments that 2D image compression strategies are feasible and efficient approaches, thus they might be applied during the acquisition of the FWD sensors.
Intraoperative bronchoscopic visualization of left ventricular assist device thrombus.
Yost, Gardner; Bhat, Geetha; Modi, Sejal; Pappas, Pat; Tatooles, Antone
2016-07-01
Despite advancements in left ventricular assist device (LVAD) design and clinical management, device thrombosis remains a pertinent complication. Limited imaging makes precise visualization of clot location and shape very challenging. We report the usage of videobronchoscopic exploration of explanted LVADs for direct visualization of clot in two patients. This technique is a rapid and inexpensive means of improving our understanding of LVAD clot formation and may be useful in surgical exploration of inflow and outflow tracts during LVAD exchange. © The Author(s) 2015.
Perez-Ecija, A; Mendoza, F J
2017-11-01
Studies have demonstrated differences in commonly measured haemostatic parameters between donkeys and horses. Whether clotting factors, anticoagulant protein activities and thromboelastography parameters also differ between species is still unknown. To characterise haemostatic parameters in healthy donkeys and to compare these with those in horses. Cross-sectional study. Clotting factors (V, VII, VIII, IX, X, XI and XII), and antithrombin III, Protein C and Protein S activities were measured in 80 healthy Andalusian and crossbred donkeys and 40 healthy Andalusian crossbred horses with assays based on human deficient plasmas. Thromboelastography was performed in 34 donkeys using a coagulation and platelet function analyser. Donkeys had shorter activated partial thromboplastin time (mean ± s.d. 33.4 ± 5.2 s vs. 38.8 ± 4.2 s; P<0.001) and higher Factor VII (1825 ± 206 vs. 1513 ± 174; P<0.001), IX (142 ± 41 vs. 114 ± 28; P<0.05) and XI (59.4 ± 14.0 vs. 27.2 ± 6.3; P<0.001) activities, whereas horses showed higher Factor X (130 ± 32 vs. 145 ± 23; P>0.05) and XII (96 ± 21 vs. 108 ± 15; P<0.001) activities. Antithrombin III (204 ± 26 vs. 174 ± 29; P<0.001), Protein C (33.16 ± 10.0 vs. 7.57 ± 1.70; P<0.001) and Protein S (median [interquartile range]: 7.8 [5.8-9.3] vs. 6.2 [5.2-7.0]; P<0.001) activities were higher in donkeys. Activated clot time (175 [159-189]), time to peak (6.5 [5.8-7.8]) and clot formation rate (26.9 [16.9-36.4]) in donkeys were shorter than reported values in horses. Haemostatic pathways could not be fully evaluated in donkeys because some tests are unavailable. Certain fibrinolytic parameters (plasmin, plasminogen, etc.) have not been characterised in donkeys and this may have affected our results. The haemostatic system in donkeys differs from that in horses and extrapolation of reference values between these species is not appropriate. © 2017 EVJ Ltd.
Rogoff, Edward G; Guirguis, Hany S; Lipton, Richard A; Seremetis, Stephanie V; DiMichele, Donna M; Agnew, George M; Karpatkin, Margaret; Barish, Robert J; Jones, Robert L; Bianco, Celso; Knothe, Barbara D; Lee, Myung-Soo
2002-10-01
Hemophilia is an expensive disease because its treatment is heavily dependent on costly clotting factor drugs. Over the last nine years,a consortium of three Comprehensive Hemophilia Treatment Centers and other hospitals, which purchased clotting factors for their patients, has seen treatment costs escalate on average 17% annually. Currently, new, even more expensive drugs are entering the market. This study analyzes 3,244 purchases that were made over a nine-year period totaling nearly 500 million units of clotting factor, representing every product on the market. Purchases were made both apart from and under the Federal Public Health Service (PHS)discount pricing rules. The main cause of the increases was the move to newer, more expensive products. The average price of existing products increased less than 2%per year, but new products were priced, on average, 47% higher than existing products. Overall consumption increased by an average of 5% per year, likely reflecting prophylactic treatment modalities that require greater amounts of clotting factor. Government pricing programs, such as the PHS program, were ineffective or counterproductive at reducing costs. There is a notable absence of competition in this market, with a few dominant companies having a functional monopoly in the largest segments of the market. Prices of older products are not lowered, even when new products are brought to market. A few products that serve small patient groups have had their prices increased substantially. This escalation is likely to continue as new, more expensive clotting factor drugs are developed. Since these new products are not proven to be any safer or more effective than the current products, this situation creates a risk of intervention by government and insurers to address both treatment costs and exhaustion of patients' insurance caps. Drug companies are not serving the patients by pricing new, but often very similar, products so aggressively. The trends seen in this patient group will likely be seen in other patient groups in the future. Ultimately, doctors and patients will lose treatment options and health care availability unless collaborative strategies are developed to reduce costs.
Code of Federal Regulations, 2010 CFR
2010-04-01
... a bleeding or clotting disorder, or anemia; (2) Blood collection container approved under section... qualifies as a health care entity, any drug indicated for a bleeding or clotting disorder, or anemia, or any...
... a lung artery. The cause is usually a blood clot in the leg called a deep vein thrombosis ... pain or coughing up blood. Symptoms of a blood clot include warmth, swelling, pain, tenderness and redness of ...
Code of Federal Regulations, 2011 CFR
2011-04-01
... a bleeding or clotting disorder, or anemia; (2) Blood collection container approved under section... qualifies as a health care entity, any drug indicated for a bleeding or clotting disorder, or anemia, or any...
Code of Federal Regulations, 2012 CFR
2012-04-01
... a bleeding or clotting disorder, or anemia; (2) Blood collection container approved under section... qualifies as a health care entity, any drug indicated for a bleeding or clotting disorder, or anemia, or any...
Code of Federal Regulations, 2013 CFR
2013-04-01
... a bleeding or clotting disorder, or anemia; (2) Blood collection container approved under section... qualifies as a health care entity, any drug indicated for a bleeding or clotting disorder, or anemia, or any...
Code of Federal Regulations, 2014 CFR
2014-04-01
... a bleeding or clotting disorder, or anemia; (2) Blood collection container approved under section... qualifies as a health care entity, any drug indicated for a bleeding or clotting disorder, or anemia, or any...
Development of a microplate coagulation assay for Factor V in human plasma
2011-01-01
Background Factor V (FV) in its activated form, FVa, is a critical regulator of thrombin generation during fibrin clot formation. There is a need of a simple, fast, and inexpensive microplate-based coagulation assay to measure the functional activity of FV in human plasma. The objective of this study was to develop a microplate-based assay that measures FV coagulation activity during clot formation in human plasma, which is currently not available. Methods The FV assay requires a kinetic microplate reader to measure the change in absorbance at 405nm during fibrin formation in human plasma. The FV assay accurately measures the time, initial rate, and extent of fibrin clot formation in human plasma. Results The FV microplate assay is simple, fast, economical, sensitive to approx 24-80pM, and multiple samples may be analyzed simultaneously. All the required materials are commercially available. Standard curves of time or initial rate of fibrin clot formation vs FV activity in the 1-stage assay (Without activation by thrombin) may be used to measure FV activity in samples of human plasma. The assay was used to demonstrate that in nine patients with disseminated intravascular coagulation (DIC), the FV 1-stage, 2-stage (With activation by thrombin), and total (2-stage activity - 1-stage activity) activities were decreased, on average, by approximately 54%, 44%, and 42%, respectively, from prolonged clot times when compared to normal pooled human reference plasma (NHP). The results indicate that the FV in the DIC patient plasmas supported both a delayed and slower rate of fibrin clot formation compared with NHP; however, the extent of fibrin clot formation in the DIC patients remained largely unchanged from that observed with NHP. Conclusions The FV microplate assay may be easily adapted to measure the activity of any coagulation factor using the appropriate factor-deficient plasma and clot initiating reagent. The microplate assay will find use in both research and clinical laboratories to provide measurement of the functional coagulation activity of FV in human plasma. PMID:21711555
Brusov, O S; Matveev, I A; Kirillov, P S; Faktor, M I; Karpova, N S; Vasilyeva, E F; Katasonov, A B; Zozulya, S A; Klushnik, T P
To assess the risk of thrombotic events in patients with schizophrenia and schizoaffective disorder based on 'fibrinodynamics' technology. A group of 76 women, including 38 with paranoid schizophrenia (F20.0), 18 with schizoaffective disorder (F25.1) in the acute stage, and 20 healthy controls, participated in the study. The technology includes the study of coagulation and fibrinolysis, Karmin author software, and calculation of peak time and hemostasis potential of spontaneous clots. Growth and lysis of fibrin clots were studied in plasma purified from platelets. All preanalytic procedures were conducted within 30 minutes after blood sampling. Blood serum was studied separately using the neuroimmunological test. Dynamic of brightness profiles of the clots was determined and a number of parameters (peak time and hemostasis potential of spontaneous clots) were calculated using the Karmin software. In patients with schizophrenia, the dynamic brightness profile of the clots has two peaks: the first peak is formed as a result of the growth and lysis of the clot initiated by the activator, the second peak is due to the growth and lysis of spontaneous clots in the volume of the measuring cuvette far from the activator. In healthy donors, the second peak under experimental conditions is absent. In the group of schizophrenic patients, a strong negative correlation is observed between the peak time of the second peak and the activity of leukocyte elastase (Spearman R = -0.75, p<0.0001), i.e. the greater the activity of elastase, the earlier the maximum of the second peak is formed and vice versa. In the control group, there is no such correlation. Evaluation of the potential of hemostasis of spontaneous clots showed that in 42% of schizophrenic patients this parameter is shifted above the norm, which indicates an increased risk of thrombosis of small brain arteries in these patients. The developed technology of 'fibrinodynamics' has a good potential for introduction into personalized medicine to identify increased risks of thrombosis of small cerebral vessels in patients with acute schizophrenia leading to the development of cognitive disorders and to control the normalization of hemostasis with antiplatelet or anticoagulant drugs.
Vaidyanathan, Subramanian; Singh, Gurpreet; Selmi, Fahed; Hughes, Peter L; Soni, Bakul M; Oo, Tun
2015-01-01
Laser lithotripsy of vesical calculi in tetraplegic subjects with long-term urinary catheters is fraught with complications because of bladder wall oedema, infection, fragile urothelium, bladder spasms, and autonomic dysreflexia. Severe haematuria should be anticipated; failure to institute measures to minimise bleeding and prevent clot retention can be catastrophic. We present an illustrative case. A tetraplegic patient underwent laser lithotripsy of vesical stone under general anaesthesia. During lithotripsy, severe bladder spasms and consequent rise in blood pressure occurred. Bleeding continued post-operatively resulting in clot retention. CT revealed clots within distended but intact bladder. Clots were sucked out and continuous bladder irrigation was commenced. Bleeding persisted; patient developed repeated clot retention. Cystoscopy was performed to remove clots. Patient developed abdominal distension. Bladder rupture was suspected; bed-side ultrasound scan revealed diffuse small bowel dilatation with mild peritoneal effusion; under-filled bladder containing small clot. Patient developed massive abdominal distension and ileus. Two days later, CT with oral positive contrast revealed intra-peritoneal haematoma at the dome of bladder with perforation at the site of haematoma. Free fluid was noted within the peritoneal cavity. This patient was managed by gastric drainage and intravenous fluids. Patient's condition improved gradually with urethral catheter drainage. Follow-up CT revealed resolution of bladder rupture, perivesical haematoma, and intra-peritoneal free fluid. If bleeding occurs, bladder irrigation should be commenced immediately after surgery to prevent clot retention. When bladder rupture is suspected, CT of abdomen should be done instead of ultrasound scan, which may not reveal bladder perforation. It is debatable whether laparotomy and repair of bladder rupture is preferable to nonoperative management in tetraplegics. Anti-muscarinic drugs should be prescribed prior to lithotripsy to control bladder spasms; aspirin and ibuprofen should be omitted. If significant bleeding occurs during lithotripsy, procedure should be stopped and rescheduled. Percutaneous cystolithotripsy using a wide channel could be quicker to clear stones, as larger fragments could be retrieved; lesser stimulant for triggering autonomic dysreflexia, as it avoids urethral manipulation. But in patients with small, contracted bladder, and protuberant abdomen, percutaneous access to urinary bladder may be difficult and can result in injury to bowels.
The phylogeny of swimming kinematics: The environment controls flagellar waveforms in sperm motility
NASA Astrophysics Data System (ADS)
Guasto, Jeffrey; Burton, Lisa; Zimmer, Richard; Hosoi, Anette; Stocker, Roman
2013-11-01
In recent years, phylogenetic and molecular analyses have dominated the study of ecology and evolution. However, physical interactions between organisms and their environment, a fundamental determinant of organism ecology and evolution, are mediated by organism form and function, highlighting the need to understand the mechanics of basic survival strategies, including locomotion. Focusing on spermatozoa, we combined high-speed video microscopy and singular value decomposition analysis to quantitatively compare the flagellar waveforms of eight species, ranging from marine invertebrates to humans. We found striking similarities in sperm swimming kinematics between genetically dissimilar organisms, which could not be uncovered by phylogenetic analysis. The emergence of dominant waveform patterns across species are suggestive of biological optimization for flagellar locomotion and point toward environmental cues as drivers of this convergence. These results reinforce the power of quantitative kinematic analysis to understand the physical drivers of evolution and as an approach to uncover new solutions for engineering applications, such as micro-robotics.
NASA Technical Reports Server (NTRS)
Collins, W.; Chang, S. H.; Kuo, J. T.
1984-01-01
Data from field surveys and biogeochemical tests conducted in Maine, Montana, and Washington strongly correlate with results obtained using high resolution airborne spectroradiometer which detects an anomalous spectral waveform that appears definitely associated with sulfide mineralization. The spectral region most affected by mineral stress is between 550 nm and 750 nm. Spectral variations observed in the field occur on the wings of the red chlorophyll band centered at about 690 nm. The metal-stress-induced variations on the absorption band wing are most successfully resolved in the high spectral resolution field data using a waveform analysis technique. The development of chlorophyll pigments was retarded in greenhouse plants doped with copper and zinc in the laboratory. The lowered chlorophyll production resulted in changes on the wings of the chlorophyll bands of reflectance spectra of the plants. The airborne spectroradiometer system and waveform analysis remains the most sensitive technique for biogeochemical surveys.
Waveform Analysis Optimization for the 45Ca Beta Decay Experiment
NASA Astrophysics Data System (ADS)
Whitehead, Ryan; 45Ca Collaboration
2017-09-01
The 45Ca experiment is searching for a non-zero Fierz interference term, which would imply a tensor type contribution to the low-energy weak interaction, possibly signaling Beyond-the-Standard-Model (BSM) physics. Beta spectrum measurements are being performed at LANL, using the segmented, large area, Si detectors developed for the Nab and UCNB experiments. 109 events have been recorded, with 38 of the 254 pixels instrumented, during the summers of 2016 and 2017. An important step to extracting the energy spectra is the correction of the waveform for pile-up events. A set of analysis tools has been developed to address this issue. A trapezoidal filter has been characterized and optimized for the experimental waveforms. This filter is primarily used for energy extraction, but, by adjusting certain parameters, it has been modified to identify pile-up events. The efficiency varies with the total energy of the particle and the amount deposited with each detector interaction. Preliminary results of this analysis will be presented.
Alian, Aymen A; Atteya, Gourg; Gaal, Dorothy; Golembeski, Thomas; Smith, Brian G; Dai, Feng; Silverman, David G; Shelley, Kirk
2016-08-01
Scoliosis surgery is often associated with substantial blood loss, requiring fluid resuscitation and blood transfusions. In adults, dynamic preload indices have been shown to be more reliable for guiding fluid resuscitation, but these indices have not been useful in children undergoing surgery. The aim of this study was to introduce frequency-analyzed photoplethysmogram (PPG) and arterial pressure waveform variables and to study the ability of these parameters to detect early bleeding in children during surgery. We studied 20 children undergoing spinal fusion. Electrocardiogram, arterial pressure, finger pulse oximetry (finger PPG), and airway pressure waveforms were analyzed using time domain and frequency domain methods of analysis. Frequency domain analysis consisted of calculating the amplitude density of PPG and arterial pressure waveforms at the respiratory and cardiac frequencies using Fourier analysis. This generated 2 measurements: The first is related to slow mean arterial pressure modulation induced by ventilation (also known as DC modulation when referring to the PPG), and the second corresponds to pulse pressure modulation (AC modulation or changes in the amplitude of pulse oximeter plethysmograph when referring to the PPG). Both PPG and arterial pressure measurements were divided by their respective cardiac pulse amplitude to generate DC% and AC% (normalized values). Standard hemodynamic data were also recorded. Data at baseline and after bleeding (estimated blood loss about 9% of blood volume) were presented as median and interquartile range and compared using Wilcoxon signed-rank tests; a Bonferroni-corrected P value <0.05 was considered statistically significant. There were significant increases in PPG DC% (median [interquartile range] = 359% [210 to 541], P = 0.002), PPG AC% (160% [87 to 251], P = 0.003), and arterial DC% (44% [19 to 84], P = 0.012) modulations, respectively, whereas arterial AC% modulations showed nonsignificant increase (41% [1 to 85], P = 0.12). The change in PPG DC% was significantly higher than that in PPG AC%, arterial DC%, arterial AC%, and systolic blood pressure with P values of 0.008, 0.002, 0.003, and 0.002, respectively. Only systolic blood pressure showed significant changes (11% [4 to 21], P = 0.003) between bleeding phase and baseline. Finger PPG and arterial waveform parameters (using frequency analysis) can track changes in blood volume during the bleeding phase, suggesting the potential for a noninvasive monitor for tracking changes in blood volume in pediatric patients. PPG waveform baseline modulation (PPG DC%) was more sensitive to changes in venous blood volume when compared with respiration-induced modulation seen in the arterial pressure waveform.
NASA Astrophysics Data System (ADS)
Bergen, K.; Yoon, C. E.; OReilly, O. J.; Beroza, G. C.
2015-12-01
Recent improvements in computational efficiency for waveform correlation-based detections achieved by new methods such as Fingerprint and Similarity Thresholding (FAST) promise to allow large-scale blind search for similar waveforms in long-duration continuous seismic data. Waveform similarity search applied to datasets of months to years of continuous seismic data will identify significantly more events than traditional detection methods. With the anticipated increase in number of detections and associated increase in false positives, manual inspection of the detection results will become infeasible. This motivates the need for new approaches to process the output of similarity-based detection. We explore data mining techniques for improved detection post-processing. We approach this by considering similarity-detector output as a sparse similarity graph with candidate events as vertices and similarities as weighted edges. Image processing techniques are leveraged to define candidate events and combine results individually processed at multiple stations. Clustering and graph analysis methods are used to identify groups of similar waveforms and assign a confidence score to candidate detections. Anomaly detection and classification are applied to waveform data for additional false detection removal. A comparison of methods will be presented and their performance will be demonstrated on a suspected induced and non-induced earthquake sequence.
Feasibility study of parallel optical correlation-decoding analysis of lightning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Descour, M.R.; Sweatt, W.C.; Elliott, G.R.
The optical correlator described in this report is intended to serve as an attention-focusing processor. The objective is to narrowly bracket the range of a parameter value that characterizes the correlator input. The input is a waveform collected by a satellite-borne receiver. In the correlator, this waveform is simultaneously correlated with an ensemble of ionosphere impulse-response functions, each corresponding to a different total-electron-count (TEC) value. We have found that correlation is an effective method of bracketing the range of TEC values likely to be represented by the input waveform. High accuracy in a computational sense is not required of themore » correlator. Binarization of the impulse-response functions and the input waveforms prior to correlation results in a lower correlation-peak-to-background-fluctuation (signal-to-noise) ratio than the peak that is obtained when all waveforms retain their grayscale values. The results presented in this report were obtained by means of an acousto-optic correlator previously developed at SNL as well as by simulation. An optical-processor architecture optimized for 1D correlation of long waveforms characteristic of this application is described. Discussions of correlator components, such as optics, acousto-optic cells, digital micromirror devices, laser diodes, and VCSELs are included.« less
Jana, Pradipta; Maiti, Smarajit; Kahn, Nighat N; Sinha, Asru K
2015-04-01
Estriol, an oestrogen, at 0.6 nmol/l was reported to inhibit ADP-induced platelet aggregation through nitric oxide synthesis. As nitric oxide has been reported to cause fibrinolysis due to the activation of plasminogen to plasmin, the role of estriol as a fibrinolytic agent was investigated. Also, the mechanism of estriol-induced nitric oxide synthesis in anucleated platelets was investigated. The estriol-induced lysis of platelet-rich plasma (PRP) clot was determined by photography of the clot lysis and by the assay of fibrin degradation products in the lysate and was obtained by SDS-PAGE. Nitric oxide was determined by methemoglobin method. The platelet membrane protein was isolated from the platelets by using Triton X-100 (0.05% v/v). The binding of estriol to the protein was determined by Scatchard plot by using an ELISA for estriol. Estriol at 0.6 nmol/l was found to lyse the clotted PRP due to fibrinolysis that produced fibrin degradation products in the lysate. The amino acid analysis of the platelet membrane protein, which resembles with nitric oxide synthase (NOS) activity, was activated nearly 10-fold over the control in the presence of estriol and was identified to be a human serum albumin precursor (Mr. 69 kDa) that binds to estriol with Kd1 of 6.0 × 10 mol/l and 39 ± 2 molecules of estriol bound the NOS molecule. The estriol-induced nitric oxide is capable of inducing fibrinolysis of the clotted PRP. The binding of estriol to platelet membrane NOS activated the enzyme in the absence of DNA in the platelet.
Mengoli, Carlo; Springer, Jan; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Klingspor, Lena; Lagrou, Katrien; Melchers, Willem J. G.; Morton, C. Oliver; Barnes, Rosemary A.; Donnelly, J. Peter; White, P. Lewis
2015-01-01
The use of serum or plasma for Aspergillus PCR testing facilitates automated and standardized technology. Recommendations for serum testing are available, and while serum and plasma are regularly considered interchangeable for use in fungal diagnostics, differences in galactomannan enzyme immunoassay (GM-EIA) performance have been reported and are attributed to clot formation. Therefore, it is important to assess plasma PCR testing to determine if previous recommendations for serum are applicable and also to compare analytical performance with that of serum PCR. Molecular methods testing serum and plasma were compared through multicenter distribution of quality control panels, with additional studies to investigate the effect of clot formation and blood fractionation on DNA availability. Analytical sensitivity and time to positivity (TTP) were compared, and a regression analysis was performed to identify variables that enhanced plasma PCR performance. When testing plasma, sample volume, preextraction-to-postextraction volume ratio, PCR volume, duplicate testing, and the use of an internal control for PCR were positively associated with performance. When whole-blood samples were spiked and then fractionated, the analytical sensitivity and TTP were superior when testing plasma. Centrifugation had no effect on DNA availability, whereas the presence of clot material significantly lowered the concentration (P = 0.028). Technically, there are no major differences in the molecular processing of serum and plasma, but the formation of clot material potentially reduces available DNA in serum. During disease, Aspergillus DNA burdens in blood are often at the limits of PCR performance. Using plasma might improve performance while maintaining the methodological simplicity of serum testing. PMID:26085614
Kim, Si Hye; Jung, Jin Tae; Kwon, Joong Goo; Kim, Eun Young; Lee, Dong Wook; Jeon, Seong Woo; Park, Kyung Sik; Lee, Si Hyung; Park, Jeong Bae; Ha, Chang Yoon; Park, Youn Sun
2015-08-01
The optimal management of bleeding peptic ulcer with adherent clot remains controversial. The purpose of this study was to compare clinical outcome between endoscopic therapy and medical therapy. We also evaluated the risk factors of rebleeding in Forrest type IIB peptic ulcer. Upper gastrointestinal (UGI) bleeding registry data from 8 hospitals in Korea between February 2011 and December 2013 were reviewed and categorized according to the Forrest classification. Patients with acute UGI bleeding from peptic ulcer with adherent clots were enrolled. Among a total of 1,101 patients diagnosed with peptic ulcer bleeding, 126 bleedings (11.4%) were classified as Forrest type IIB. Of the 126 patients with adherent clots, 84 (66.7%) received endoscopic therapy and 42 (33.3%) were managed with medical therapy alone. The baseline characteristics of patients in two groups were similar except for higher Glasgow Blatchford Score and pre-endoscopic Rockall score in medical therapy group. Bleeding related mortality (1.2% vs.10%; p=0.018) and all cause mortality (3.7% vs. 20.0%; p=0.005) were significantly lower in the endoscopic therapy group. However, there was no difference between endoscopic therapy and medical therapy regarding rebleeding (7.1% vs. 9.5%; p=0.641). In multivariate analysis, independent risk factors of rebleeding were previous medication with aspirin and/or NSAID (OR, 13.1; p=0.025). In patients with Forrest type IIB peptic ulcer bleeding, endoscopic therapy was associated with a significant reduction in bleeding related mortality and all cause mortality compared with medical therapy alone. Important risk factor of rebleeding was use of aspirin and/or NSAID.
Loeffler, Juergen; Mengoli, Carlo; Springer, Jan; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Klingspor, Lena; Lagrou, Katrien; Melchers, Willem J G; Morton, C Oliver; Barnes, Rosemary A; Donnelly, J Peter; White, P Lewis
2015-09-01
The use of serum or plasma for Aspergillus PCR testing facilitates automated and standardized technology. Recommendations for serum testing are available, and while serum and plasma are regularly considered interchangeable for use in fungal diagnostics, differences in galactomannan enzyme immunoassay (GM-EIA) performance have been reported and are attributed to clot formation. Therefore, it is important to assess plasma PCR testing to determine if previous recommendations for serum are applicable and also to compare analytical performance with that of serum PCR. Molecular methods testing serum and plasma were compared through multicenter distribution of quality control panels, with additional studies to investigate the effect of clot formation and blood fractionation on DNA availability. Analytical sensitivity and time to positivity (TTP) were compared, and a regression analysis was performed to identify variables that enhanced plasma PCR performance. When testing plasma, sample volume, preextraction-to-postextraction volume ratio, PCR volume, duplicate testing, and the use of an internal control for PCR were positively associated with performance. When whole-blood samples were spiked and then fractionated, the analytical sensitivity and TTP were superior when testing plasma. Centrifugation had no effect on DNA availability, whereas the presence of clot material significantly lowered the concentration (P = 0.028). Technically, there are no major differences in the molecular processing of serum and plasma, but the formation of clot material potentially reduces available DNA in serum. During disease, Aspergillus DNA burdens in blood are often at the limits of PCR performance. Using plasma might improve performance while maintaining the methodological simplicity of serum testing. Copyright © 2015 Loeffler et al.
Kocijancic, Marija; Cargonja, Jelena; Delic-Knezevic, Alma
2014-01-01
Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer(®) Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum separation. Our aim was to evaluate the comparability of routine chemistry parameters in BD Vacutainer(®) RST blood collection tube in reference with the BD Vacutainer(®) Serum Separating Tubes II Advance Tube (SST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA). Blood specimens were collected from 90 participants for evaluation on its results, clotting time and stability study of six routine biochemistry parameters: glucose (Glu), aspartate aminotransferase (AST), alanine aminotransferase (ALT), calcium (Ca), lactate dehidrogenase (LD) and potassium (K) measured with Olympus AU2700 analyzer (Beckman Coulter, Tokyo, Japan). The significance of the differences between samples was assessed by paired t-test or Wilcoxon Matched-Pairs Rank test after checking for normality. Clotting process was significantly shorter in the RSTs compared to SSTs (2.49 min vs. 19.47 min, respectively; P < 0.001). There was a statistically significant difference between the RST and SST II tubes for glucose, calcium and LD (P < 0.001). Differences for glucose and LD were also clinically significant. Analyte stability studies showed that all analytes were stable for 24 h at 4 °C. Most results (except LD and glucose) from RST are comparable with those from SST. In addition, RST tube provides shorter clotting time.
Augmented kludge waveforms for detecting extreme-mass-ratio inspirals
NASA Astrophysics Data System (ADS)
Chua, Alvin J. K.; Moore, Christopher J.; Gair, Jonathan R.
2017-08-01
The extreme-mass-ratio inspirals (EMRIs) of stellar-mass compact objects into massive black holes are an important class of source for the future space-based gravitational-wave detector LISA. Detecting signals from EMRIs will require waveform models that are both accurate and computationally efficient. In this paper, we present the latest implementation of an augmented analytic kludge (AAK) model, publicly available at https://github.com/alvincjk/EMRI_Kludge_Suite as part of an EMRI waveform software suite. This version of the AAK model has improved accuracy compared to its predecessors, with two-month waveform overlaps against a more accurate fiducial model exceeding 0.97 for a generic range of sources; it also generates waveforms 5-15 times faster than the fiducial model. The AAK model is well suited for scoping out data analysis issues in the upcoming round of mock LISA data challenges. A simple analytic argument shows that it might even be viable for detecting EMRIs with LISA through a semicoherent template bank method, while the use of the original analytic kludge in the same approach will result in around 90% fewer detections.
Speech waveform perturbation analysis: a perceptual-acoustical comparison of seven measures.
Askenfelt, A G; Hammarberg, B
1986-03-01
The performance of seven acoustic measures of cycle-to-cycle variations (perturbations) in the speech waveform was compared. All measures were calculated automatically and applied on running speech. Three of the measures refer to the frequency of occurrence and severity of waveform perturbations in special selected parts of the speech, identified by means of the rate of change in the fundamental frequency. Three other measures refer to statistical properties of the distribution of the relative frequency differences between adjacent pitch periods. One perturbation measure refers to the percentage of consecutive pitch period differences with alternating signs. The acoustic measures were tested on tape recorded speech samples from 41 voice patients, before and after successful therapy. Scattergrams of acoustic waveform perturbation data versus an average of perceived deviant voice qualities, as rated by voice clinicians, are presented. The perturbation measures were compared with regard to the acoustic-perceptual correlation and their ability to discriminate between normal and pathological voice status. The standard deviation of the distribution of the relative frequency differences was suggested as the most useful acoustic measure of waveform perturbations for clinical applications.
Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure
NASA Astrophysics Data System (ADS)
Zielinski, Todd M.; Hettrick, Doug; Cho, Yong
2010-04-01
Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p < 0.05) comparing baseline VTI to phenylephrine VTI (246 ± .05 ms to 320 ± .07 ms) and baseline admittance waveform maximum to phenylephrine admittance waveform maximum (0.0148 ± .002 siemens to 0.0151 ± .002 siemens). Conclusion: Chronic minimally invasive admittance measurement techniques that monitor relative change in blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.
... Stroke and atherosclerosis There are two types of ischemic stroke caused by blood clots, narrowing of blood vessels ... 2 What Is an Arteriovenous Malformation (AVM)? 3 Ischemic Strokes (Clots) 4 Hemorrhagic Strokes (Bleeds) 5 What You ...
... is used to control bleeding that occurs when blood clots are broken down too quickly. This type of ... doctor if you have or have ever had blood clots or heart, liver or kidney disease.tell your ...
... aortic aneurysm - CTA chest; Venous thromboembolism - CTA lung; Blood clot - CTA lung; Embolus - CTA lung; CT pulmonary angiogram ... angiogram may be done: For symptoms that suggest blood clots in the lungs, such as chest pain, rapid ...
... to the blood vessel as the needle and catheter are inserted Blood clot traveling to the lungs, causing an embolism Excessive bleeding or a blood clot where the catheter is inserted, which can reduce blood flow to ...