Sample records for cm active length

  1. Evaluation of different captive bolt lengths and breed influence upon post-stun hind limb and forelimb activity in fed cattle at a commercial slaughter facility.

    PubMed

    Martin, Miriam S; Kline, Helen C; Wagner, Dana R; Alexander, Lacey R; Edwards-Callaway, Lily N; Grandin, Temple

    2018-05-03

    The objective of this study was to assess the effects of captive bolt length and breed type on post-stun leg activity in cattle. A total of 2850 Holstein (HOL) and non-Holstein British/Continental bred (NHOL) steers and heifers were observed post-stunning at a large commercial slaughter facility. A pneumatically powered penetrating captive bolt stunner was used with three different bolt lengths: CON, 15.24 cm; MED, 16.51 cm; and LON, 17.78 cm. Hind limb kicking, forelimb activity, take away belt stops, carcass swing and number of knife sticks during exsanguination were recorded for each animal from video recording. Hind limb and forelimb kicks observed ranged from 0 to 25 and 0 to 8, respectively. Analysis of post-stun hind limb and forelimb activity indicated that increasing pneumatically powered penetrating captive bolt length does not decrease post-stun leg activity. There was a higher percentage of cattle experiencing take away belt stops and carcass swing in HOL as compared with NHOL. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Simulations on false gain in recombination-pumped soft-X-ray lasers

    NASA Astrophysics Data System (ADS)

    Ozaki, T.; Kuroda, H.

    1997-10-01

    Numerical investigations are performed on false gain due to axial plasma expansion, which is expected to be important in initial proof-of-principle studies of recombination-pumped soft-X-ray lasers with extended capabilities. Modelling calculations of experiments with slab boron nitride targets reveal large false gain coefficients approaching 20 cm-1 in the case of plasmas with short active medium lengths. The false gain in the case of fiber targets is found to be of equal magnitude to that for slabs in the case of plasmas with less than 0.1 cm active medium lengths. Calculations for slab targets predict that adopting a tolerance of ǃ cm-1 for gain will severely restrict the time and the active medium length of the plasma that can be used for error-free observations, while those for fiber targets are found to be considerably relaxed. The effects of false gain in the 54.2 + Na Balmer ! laser is also investigated, again revealing the importance of this phenomena under optimum gain conditions.

  3. An in vitro study of magnetic particle targeting in small blood vessels

    NASA Astrophysics Data System (ADS)

    Udrea, Laura Elena; Strachan, Norval J. C.; Bădescu, Vasile; Rotariu, Ovidiu

    2006-10-01

    The magnetic guidance and capture of particles inside the human body, via the circulatory system, is a novel method for the targeted delivery of drugs. This experimental study confirms in vitro that a dipolar capturing device, based on high-energy magnets with an active space of 8.7 cm × 10 cm × 10 cm, retains colloidal magnetic particles (MPs) (<30 nm) injected in the capillary tubes, where flow velocities are comparable to that encountered in the capillary beds of tumours (<0.5 cm s-1). The build-up of the deposition of the MPs was investigated using video imaging techniques that enabled continuous monitoring of the blocking of the vessel whilst simultaneously recording the colloid's flow rate. The parameters of practical importance (length of MP deposit, time of capillary blocking) were estimated and were found to be dependent on the initial fluid velocity, the MP concentration and the distance between the capillary tube and the polar magnetic pieces. Although the tube used in this experiment is larger (diameter = 0.75 mm, length = 100 mm) than that of real capillaries (diameter = 0.01 mm, length ~1.5 mm), the flow velocities chosen were similar to those encountered in the capillary beds of tumours and the length/diameter ratio was approximately equal (133 for the present set-up, 100-150 for real capillaries). In these circumstances and using the same magnetic field conditions (intensity, gradient) and MPs, there is close similarity with magnetic capture in a microscopic capillary system. Moreover, the macroscopic system permits analysis of the distribution of MPs in the active magnetic space, and consequently the maximum targetable volume. This study revealed that the capture of particles within the active space was strongly influenced by the gradient of the magnetic field and the flow velocity. Thus, when the magnetic field gradient had medium values (0.1-0.3 T cm-1) and the fluid velocity was small (0.15 cm s-1), the particles were captured in small, compact and stable deposits (L < 4 cm) and the time necessary for blocking of the capillary was <150 s. Doubling the value for the flow velocity did not influence significantly either the length of MP deposits nor the blocking time. However, lower gradients (<0.1 T cm-1) and larger velocities (0.3-0.9 cm s-1) result in the formation of larger deposits (4 cm < L < 10 cm) that are unstable at the beginning of the capture process. These large deposits do become stable given sufficient time for the deposition process to take place in conjunction with a decrease in the flow rate. As a consequence, the time necessary for blocking of the capillary increased up to 450 s. Decreasing the MP concentration from 0.02 g cm-3 to 0.005 g cm-3 decreased the deposit lengths by approximately 20% and doubled the values of the blocking time. The maximum targetable volume obtained by the present method is ~350 cm3, which corresponds to medium-sized tumours. The capillary vessels were blocked only for the situation that occurs for microcirculation within a tumour. This reduces the concentration of MPs trapped within the normal tissues, which occurs when using particles of micrometre size. This work showed the potential of using colloidal MPs and dipolar magnetic devices for treatment of human patients, when the affected sites are positioned at medium distances from the surface of the body (e.g. head, neck, breast, hands and legs).

  4. Factors affecting poor nutritional status after small bowel resection in patients with Crohn disease.

    PubMed

    Jang, Ki Ung; Yu, Chang Sik; Lim, Seok-Byung; Park, In Ja; Yoon, Yong Sik; Kim, Chan Wook; Lee, Jong Lyul; Yang, Suk-Kyun; Ye, Byong Duk; Kim, Jin Cheon

    2016-07-01

    In Crohn disease, bowel-preserving surgery is necessary to prevent short bowel syndrome due to repeated operations. This study aimed to determine the remnant small bowel length cut-off and to evaluate the clinical factors related to nutritional status after small bowel resection in Crohn disease.We included 394 patients (69.3% male) who underwent small bowel resection for Crohn disease between 1991 and 2012. Patients who were classified as underweight (body mass index < 17.5) or at high risk of nutrition-related problems (modified nutritional risk index < 83.5) were regarded as having a poor nutritional status. Preliminary remnant small bowel length cut-offs were determined using receiver operating characteristic curves. Variables associated with poor nutritional status were assessed retrospectively using Student t tests, chi-squared tests, Fisher exact tests, and logistic regression analyses.The mean follow-up period was 52.9 months and the mean patient ages at the time of the last bowel surgery and last follow-up were 31.2 and 35.7 years, respectively. The mean remnant small bowel length was 331.8 cm. Forty-three patients (10.9%) underwent ileostomy, 309 (78.4%) underwent combined small bowel and colon resection, 111 (28.2%) had currently active disease, and 105 (26.6%) underwent at least 2 operations for recurrent disease. The mean body mass index and modified nutritional risk index were 20.6 and 100.8, respectively. The independent factors affecting underweight status were remnant small bowel length ≤240 cm (odds ratio: 4.84, P < 0.001), ileostomy (odds ratio: 4.70, P < 0.001), and currently active disease (odds ratio: 4.16, P < 0.001). The independent factors affecting high nutritional risk were remnant small bowel length ≤230 cm (odds ratio: 2.84, P = 0.012), presence of ileostomy (odds ratio: 3.36, P = 0.025), and currently active disease (odds ratio: 4.90, P < 0.001).Currently active disease, ileostomy, and remnant small bowel length ≤230 cm are risk factors affecting the poor nutritional status of patients with Crohn disease after small bowel resection.

  5. Mechanics of smooth muscle in isolated single microvessels.

    PubMed

    Gore, R W; Davis, M J

    1984-01-01

    In vivo studies on frog mesenteric arterioles (4) indicate that segmental differences in the response of microvessels to physical and chemical stimuli can be explained simply in terms of the length-tension characteristics of vascular smooth muscle at different points along the vascular tree. Studies on single, isolated arterioles in vitro were initiated to examine more closely the validity of this explanation for regional response differences. This paper reports some of the results. First-, second-, and third-order arterioles (18-60 micron i.d.) were dissected from hamster cheek pouches. The vessels were cannulated with a modified Burg microperfusion system, and their mechanical properties studied using the methods described by Duling and Gore. Vessels were activated in four stages with K+ and norepinephrine. During activation, transmural pressures were adjusted to minimize vascular smooth-muscle shortening. Active pressure-diameter curves were recorded while adjusting transmural pressure through the range 5 to 400 cm H20 in 5-25 cm steps. Vessel dimensions were measured with a videomicrometer. Passive curves were obtained after equilibration overnight in Ca2+-free medium. The vessels were then fixed and prepared for histologic sectioning, and measurements of vessel-wall composition were made. The Laplace relationship was used to construct length-tension diagrams, and the histologic data were used to normalize the dimensional data to smooth-muscle lengths. Maximum active tension of second-order arterioles (1,170 dynes/cm) was two times previous values reported by Gore et al. This was due presumably to refinements in techniques and dissection procedures. Maximum active stress averaged 3.9 X 10(+6) dynes/cm2 for second-order arterioles. This number is identical to data obtained from hog carotid strips by Dillon et al.

  6. Estimation of laceration length by emergency department personnel.

    PubMed

    Bourne, Christina L; Jenkins, M Adams; Brewer, Kori L

    2014-11-01

    Documentation and billing for laceration repair involves a description of wound length. We designed this study to test the hypothesis that emergency department (ED) personnel can accurately estimate wound lengths without the aid of a measuring device. This was a single-center prospective observational study performed in an academic ED. Seven wounds of varying lengths were simulated by creating lacerations on purchased pigs' ears and feet. We asked healthcare providers, defined as nurses and physicians working in the ED, to estimate the length of each wound by visual inspection. Length estimates were given in centimeters (cm) and inches. Estimated lengths were considered correct if the estimate was within 0.5 cm or 0.2 inches of the actual length. We calculated the differences between estimated and actual laceration lengths for each laceration and compared the accuracy of physicians to nurses using an unpaired t-test. Thirty-two physicians (nine faculty and 23 residents) and 16 nurses participated. All subjects tended to overestimate in cm and inches. Physicians were able to estimate laceration length within 0.5 cm 36% of the time and within 0.2 inches 29% of the time. Physicians were more accurate at estimating wound lengths than nurses in both cm and inches. Both physicians and nurses were more accurate at estimating shorter lengths (<5.0 cm) than longer (>5.0 cm). ED personnel are often unable to accurately estimate wound length in either cm or inches and tend to overestimate laceration lengths when based solely on visual inspection.

  7. Bending effects and temperature dependence of magnetic properties in a Fe-rich amorphous wire

    NASA Astrophysics Data System (ADS)

    Bordin, G.; Buttino, G.; Poppi, M.

    2001-08-01

    Amorphous wires with composition Fe 77.5Si 7.5B 15 exhibit a very peculiar magnetization process characterized by a single and quite large Barkhausen jump. This gives rise to a squared hysteresis loop at a critical magnetic field. The bistable behaviour, widely studied in wires with typical length of 10 cm and diameter of 125 μm, appears above a length of about 7 cm in straight wires and disappears for curvature radius within the range 2-12 cm in bent wires. In this work it is shown that bistability occurs in bent wires, whatever their curvature is, provided the wires are long enough. To this purpose spiral-shaped samples with several turns are considered. However, when the wire length is not a integer number of turns the magnetization reverses through many large Barkhausen jumps. In this condition, varying the measuring temperature can activate the energy barriers for the jumps.

  8. Life-stages, exploitation status and habitat use of Lutjanus goreensis (Perciformes: Lutjanidae) in coastal marine environments of Lagos, SW Nigeria.

    PubMed

    Kafayat, A Fakoya; Martins, A Anetekhai; Shehu, L Akintola; Abdulwakil, O Sabal; Abass, Mikhail A

    2015-03-01

    The Gorean snapper, Lutanus goreensis is an important component of artisanal fisheries and trawl landings in the Gulf of Guinea. Despite its economic importance, there is a dearth of information on size structure and life history strategies of the species. Therefore, the objectives of this study were to provide baseline data on the life stages, exploitation status and habitat use for the species in Nigeria. Monthly samples were obtained from artisanal and trawl catches in Five Cowrie Creek and Lagos coastal waters between December 2008 and December 2010, respectively. Length-frequency distributions of the fishes caught were analysed to provide preliminary information on mean and modal lengths at capture and life-history strategies based on habitat use and estuarine-dependency for L. goreensis. A total of 822 specimens of L. goreensis were collected from Five Cowrie Creek while 377 specimens were collected from Lagos coastal waters. Total length varied between 7.90-34.90 cm for creek samples and from 21.90-56.10 cm for marine samples. Length-frequency histograms showed polymodal size distributions in creek and marine samples. Length-frequency distributions of L. goreensis showed a high abundance ofjuveniles (<20 cm) and sub-adults (20-35 cm) which accounted for 84.1% and 68.4% of creek and marine samples examined, respectively. For the creek samples, fish in modal length class of 13.00-13.99 cm were the most exploited while in the marine samples, length classes of 29.00-30.99 cm and 31.00-32.99cm constituted the most frequently exploited fishes. Increase in total lengths from the creek (mean +/- SD; 16.19 +/- 3.73 cm) to the marine habitat samples (32.89 +/- 6.14 cm) indicated ontogenetic shift in habitat use. Occurrence of a predominant juvenile population in Five Cowrie Creek by L. goreensis suggests estuarine-dependency and is indicative of a temporary juvenile habitat or a migratory corridor. In conclusion, data from the presently reported study and previous studies demonstrated that juvenile L. goreensis displays estuarine dependency and habitat flexibility. Hence, this underscores the importance of preserving estuarine environments as essential fish habitats to prevent overfishing. The study also concludes that the species is vulnerable to recruitment overfishing in the marine environment especially as a consequence of shrimping. Consequently, it advocates for ban on all fishing activities during peak spawning periods in breeding grounds and shrimp ground assemblage.

  9. Management of fibular hemimelia using the Ilizarov method at Siriraj Hospital in Thailand.

    PubMed

    Unprasert, Prangthong; Kaewpornsawan, Kamolporn; Chotigavanichaya, Chatupon; Eamsobhana, Perajit

    2014-09-01

    Fibular hemimelia is one of the most common congenital longitudinal bone deficiencies. Previous treatment protocols called for amputation of the deficient limb; while others made attempts to save the limb. The objective of treatment is to restore function and achieve patient satisfaction. The authors evaluated the outcomes of the Ilizarov technique for the treatment of leg-length discrepancy and bone associated deformities in patients with fibular hemimelia. The present study also evaluated and assessed complications, knee and ankle function, and patient satisfaction with the treatment. Nine patients with fibular hemimelia who underwent tibial lengthening using the Ilizarov method were reviewed in the present study. Initial condition data, including age, gender type offibular hemimelia, initial limb-length discrepancy, predicted limb-length discrepancy, and the data were collected and analyzed. Activity level, patient satisfaction, complications, and residual leg-length discrepancy were assessed at the end of treatment. According to Achterman and Kalamchi classification, there were 4 patients with Type IA, 3 patients with Type IB, and 2 patients with Type II. In Type IA, the affected leg-length discrepancy and mean age at the initial treatment were 3.25 cm and 7.75 years, respectively. In type IB, the affected leg-length discrepancy and mean age at the initial treatment were 5.83 cm and 4.3 years, respectively. In Type II, the affected leg-length discrepancy and mean age at the initial treatment were 5.5 cm and 5 years, respectively. The mean follow-up was 5 years (range: 7-10). The mean lengthening was 7.52 cm (range: 4-13). The lengthening index was 1.28 mo/cm. The mean residual leg-length discrepancy was 0.94 cm. There was ankle joint stiffness and mild equinous foot in type II cases, but patients could walk well without gait aid. No patients were experiencing pain by the end of treatment. All patients expressed satisfaction with this technique. The Ilizarov technique for bone lengthening of the tibia has shown satisfactory results in the treatment of all types of congenital fibular hemimelia and should be considered an attractive alternative to amputation, as measureable functional improvement can be expected.

  10. Antimicrobial activity and agricultural properties of bitter melon (Momordica charantia L.) grown in northern parts of Turkey: a case study for adaptation.

    PubMed

    Yaldız, Gülsüm; Sekeroglu, Nazım; Kulak, Muhittin; Demirkol, Gürkan

    2015-01-01

    This study was designed to determine the adaptation capability of bitter melon (Momordica charantia L.), which is widely grown in tropical and subtropical climates, in northern parts of Turkey. In this study, plant height, number of fruits, fruit length, fruit width, number of seeds and fruit weight of bitter melon grown in field conditions were determined. The antimicrobial effect of the ethanol extract of fruit and seeds against Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus, Salmonella typhi, Aspergillus niger and Candida albicans microorganisms was tested in vitro by the disc diffusion method. In conclusion, plant height (260 cm), number of fruits (16 per  plant), number of seeds (30.2  per fruit), fruit width (3.8 cm), fruit length (10.6 cm) and fruit weight (117.28 g fruit(- 1)) were determined; fruits were found to have antimicrobial activity against A. niger; oil and seeds were found to have antimicrobial activity against A. niger and E. coli.

  11. Life-history traits of the long-nosed skate Dipturus oxyrinchus.

    PubMed

    Bellodi, A; Porcu, C; Cannas, R; Cau, Al; Marongiu, M F; Mulas, A; Vittori, S; Follesa, M C

    2017-03-01

    This work investigates life-history traits of the long-nosed skate Dipturus oxyrinchus, which is a common by-catch in Sardinian waters. The reproductive variables were analysed from 979 specimens sampled during scientific and commercial hauls. Females (10·4-117·5 cm total length, L T ) attained larger sizes than males (14·5-99·5 cm L T ). To evaluate age and growth, a sub-sample of 130 individuals (76 females and 54 males) were used. The age was estimated by annuli counts of sectioned vertebral centra. Four models were used for the length-at-age data: the von Bertalanffy, the exponential, the Gompertz and the logistic functions. According to the Akaike's information criterion, the Gompertz model seemed to provide the best fitting curve (L ∞ mean ± s.e.: 127·55 ± 4·90 cm, k: 0·14 ± 0·09, IP: 3·97 ± 0·90 years). The oldest female and male were aged 17 (115·5 cm L T ) and 15 years (96·0 cm L T ), respectively. Lengths at maturity were 103·5 cm for females and 91·0 cm for males, corresponding to 90% of the maximum observed length in both sexes. The monthly distribution of maturity stages highlighted an extended reproductive cycle, with spawning females and active males being present almost throughout the year, as confirmed by the gonado-somatic index. Ovarian fecundity reached a maximum of 26 yolked follicles with a mean ± s.e. size of 19·7 ± 6·5 mm. © 2016 The Fisheries Society of the British Isles.

  12. [Effects of water storage in deeper soil layers on the root growth, root distribution and economic yield of cotton in arid area with drip irrigation under mulch].

    PubMed

    Luo, Hong-Hai; Zhang, Hong-Zhi; Zhang, Ya-Li; Zhang, Wang-Feng

    2012-02-01

    Taking cotton cultivar Xinluzao 13 as test material, a soil column culture expenment was conducted to study the effects of water storage in deeper (> 60 cm) soil layer on the root growth and its relations with the aboveground growth of the cultivar in arid area with drip irrigation under mulch. Two levels of water storage in 60-120 cm soil layer were installed, i. e., well-watered and no watering, and for each, the moisture content in 0-40 cm soil layer during growth period was controlled at two levels, i.e., 70% and 55% of field capacity. It was observed that the total root mass density of the cultivar and its root length density and root activity in 40-120 cm soil layer had significant positive correlations with the aboveground dry mass. When the moisture content in 0-40 cm soil layer during growth season was controlled at 70% of field capacity, the total root mass density under well-watered and no watering had less difference, but the root length density and root activity in 40-120 cm soil layer under well-watered condition increased, which enhanced the water consumption in deeper soil layer, increased the aboveground dry mass, and finally, led to an increased economic yield and higher water use efficiency. When the moisture content in 0-40 cm soil layer during growth season was controlled at 55% of field capacity and the deeper soil layer was well-watered, the root/shoot ratio and root length density in 40-120 cm soil layer and the root activity in 80-120 cm soil layer were higher, the water consumption in deeper soil layer increased, but it was still failed to adequately compensate for the negative effects of water deficit during growth season on the impaired growth of roots and aboveground parts, leading to a significant decrease in the economic yield, as compared with that at 70% of field capacity. Overall, sufficient water storage in deeper soil layer and a sustained soil moisture level of 65% -75% of field capacity during growth period could promote the downward growth of cotton roots, which was essential for achieving water-saving and high-yielding cultivation of cotton with drip irrigation under mulch.

  13. Undoped polythiophene field-effect transistors with mobility of 1 cm2 V-1 s-1

    NASA Astrophysics Data System (ADS)

    Hamadani, B. H.; Gundlach, D. J.; McCulloch, I.; Heeney, M.

    2007-12-01

    We report on charge transport in organic field-effect transistors based on poly(2,5-bis(3-tetradecylthiophen-2-yl)thieno[3,2-b]thiophene) as the active polymer layer with saturation field-effect mobilities as large as 1cm2V-1s-1. This is achieved by employing Pt instead of the commonly used Au as the contacting electrode and allows for a significant reduction in the metal/polymer contact resistance. The mobility increases as a function of decreasing channel length, consistent with a Poole-Frenkel model of charge transport, and reaches record mobilities of 1cm2V-1s-1 or more at channel lengths on the order of few microns in an undoped solution-processed polymer cast on an oxide gate dielectric.

  14. Uterine length and fertility outcomes: a cohort study in the IVF population.

    PubMed

    Hawkins, L K; Correia, K F; Srouji, S S; Hornstein, M D; Missmer, S A

    2013-11-01

    What is the relationship between pre-cycle uterine length and IVF outcome (chemical pregnancy, clinical pregnancy, spontaneous abortion and live birth)? Women at extremes of uterine length (<7.0 or >9.0 cm) were less likely to achieve live birth and women with uterine lengths <6.0 cm were also more likely to experience spontaneous abortion. A prospective study of 807 women published in 2000 found that implantation and clinical pregnancy rates were highest in women with uterine lengths between 7.0 and 9.0 cm, though the difference was not significant. The relationship between pre-cycle uterine length and live birth has not been evaluated. A retrospective cohort study of all cycles performed after uterine length measurement at an academic hospital IVF clinic from 2001 to 2012. A total of 8981 fresh cycles were performed in 5120 adult women with normal uterine anatomy. Women with uterine anomalies (unicornuate, bicornuate, septate or uterus exposed to diethylstilbestrol) were excluded and women with fibroids were identified for subanalysis. Uterine length was measured by uterine sounding. Cycles were divided by uterine length into groups: <6.0 cm (very short, n = 76), 6.0-6.9 cm (short, n = 2014), 7.0-7.9 cm (referent, n = 4984), 8.0-8.9 cm (long, n = 1664) and ≥9 cm (very long, n = 243). Multivariate logistic regression (first-cycle analyses) and generalized estimating equations (all-cycle analyses) were adjusted for age, fibroids and ART treatment (assisted hatching, intracytoplasmic sperm injection) to generate relative risk (RR) of cycle outcomes by uterine length. Median uterine length in the IVF population was 7.0 cm (interquartile range 7.0-7.8) and was positively associated with BMI (P < 0.001) and fibroids (P = 0.02). Compared with the referent group, women with uterine lengths <6.0 cm were half as likely to achieve live birth (RR: 0.53; 95% confidence interval (CI): 0.35-0.81) and women with lengths of 6.0-6.9 cm were also less likely (RR: 0.91; CI: 0.85-0.98). Cubic regression spline identified a significant inverse U-shaped association whereby women with uterine lengths <7.0 or >9.0 cm were less likely to achieve live birth. Women with lengths <6.0 cm were also more likely to experience spontaneous abortion (RR: 2.16; CI: 1.23-3.78). Results remained consistent when excluding women with a uterine factor diagnosis (n = 8823), when limiting to the first cycle at our institution (n = 5120) and when further restricting to first-ever cycles (n = 3941). Optimal assessment of uterine length by ultrasound was not feasible due to time and cost limitations, though uterine sounding is a clinically relevant measurement allowing for results with practical implications. Findings from our predominantly Caucasian clinic population may not be generalizable to infertile populations with different ethnic compositions. Reproducibility of results would solidify findings and inform patient counseling in women undergoing IVF. No funding was sought for this investigation. MD declares relationships with UpToDate (royalties) and WINFertlity (consultant).

  15. Thermal neutron flux mapping in a head phantom

    NASA Astrophysics Data System (ADS)

    Lee, C. L.; Zhou, X.-L.; Harmon, J. F.; Bartholomay, R. W.; Harker, Y. D.; Kudchadker, R. J.

    1999-02-01

    Boron neutron capture therapy (BNCT) is a binary cancer treatment modality in which a boron-containing compound is preferentially loaded into a tumor, followed by irradiation by thermal neutrons. In accelerator-based BNCT, neutrons are produced by charged particle-induced reactions such as 7Li(p, n) 7Be. For deeply seated brain tumors, epithermal (1 eV to 10 kev) neutrons are needed to penetrate the skull cap and subsequently thermalize at the tumor location. Cell damage in BNCT is caused by the high linear energy transfer (LET) products from the 10B(n, α) 7Li reaction. Because the cross section for this reaction is of 1/ v character, the dose due to 10B has essentially the same spatial distribution as the thermal neutron flux. A cylindrical acrylic head phantom (15.24 cm diameter by 21.59 cm length) has been constructed to simulate the patient's head and neck, and acrylic spacers of varying width allow placement of small (active sizes: 0.635 cm diameter by 1.27 cm length and 1.5875 cm diameter by 2.54 cm length) BF 3 proportional counters at nearly all radial and axial locations. Measurements of the thermal flux have also been benchmarked with gold and indium foils (bare and cadmium covered), as well as MCNP simulations. Measurement of the thermal neutron flux using these small BF 3 counters is shown to be adequate for experimentally determining the spatial variation of the 10B dose in head phantoms for accelerator-based BNCT.

  16. Critical swimming speeds of wild bull trout

    USGS Publications Warehouse

    Mesa, M.G.; Weiland, L.K.; Zydlewski, G.B.

    2004-01-01

    We estimated the critical swimming speeds (Ucrit) of wild bull trout at 6??, 11??, and 15??C in laboratory experiments. At 11??C, 5 fish ranging from 11 to 19 cm in length had a mean Ucrit of 48.24 cm/s or 3.22 body lengths per second (BL/s). Also at 11??C , 6 fish from 32 to 42 cm had a mean Ucrit of 73.99 cm/s or 2.05 BL/s. At 15??C, 5 fish from 14 to 23 cm had a mean Ucrit of 54.66 cm/s or 2.88 BL/s. No fish successfully swam at 6??C. Swim speed was significantly influenced by fish length. Many bull trout performed poorly in our enclosed respirometers: of 71 Ucrit tests we attempted, only the 16 described above were successful. Bull trout that refused to swim held station within tunnels by using their pectoral fins as depressors, or they rested and later became impinged against a downstream screen. Several common techniques did not stimulate consistent swimming activity in these fish. Our estimates of U crit for bull trout provide an understanding of their performance capacity and will be useful in modeling efforts aimed at improving fish passage structures. We recommend that fishway or culvert designers concerned with bull trout passage maintain velocities within their structures at or below our estimates of Ucrit, thus taking a conservative approach to ensuring that these fish can ascend migratory obstacles safely.

  17. A comprehensive, prospective study of penile dimensions in Chinese men of multiple ethnicities.

    PubMed

    Chen, X B; Li, R X; Yang, H N; Dai, J C

    2014-01-01

    This study aimed to establish a reference range of penile length and circumference of adult males in China, and to compare the penile dimensions of different ethnical backgrounds. To do this, penile length and circumference measurements were obtained from 5196 healthy males attending the Urology Counseling Clinic. The mean value of penile dimensions was a flaccid length of 6.5 ± 0.7 cm, a stretched length of 12.9 ± 1.2 cm and a flaccid circumference of 8.0 ± 0.8 cm. In the subgroup of 311 males, the mean erectile length was 12.9 ± 1.3 cm and the mean erectile circumference was 10.5 ± 0.9 cm, the mean flaccid and erectile glans lengths were 2.7 ± 0.3 and 3.4 ± 0.4 cm, respectively, and the mean flaccid and erectile glans diameters were 2.6 ± 0.2 and 3.4 ± 0.4 cm, respectively. We found that flaccid penile length and circumference varied among different ethnicities. This study established a reference range for penile dimensions, which will help when counseling patients worried about their penile size or seeking penis enlargement surgery. We also found that penile dimensions are different in different ethnicities, but further investigations are needed to validate this.

  18. Penile length and circumference: an Indian study.

    PubMed

    Promodu, K; Shanmughadas, K V; Bhat, S; Nair, K R

    2007-01-01

    Apprehension about the normal size of penis is a major concern for men. Aim of the present investigation is to estimate the penile length and circumference of Indian males and to compare the results with the data from other countries. Results will help in counseling the patients worried about the penile size and seeking penis enlargement surgery. Penile length in flaccid and stretched conditions and circumference were measured in a group of 301 physically normal men. Erected length and circumference were measured for 93 subjects. Mean flaccid length was found to be 8.21 cm, mean stretched length 10.88 cm and circumference 9.14 cm. Mean erected length was found to be 13.01 cm and erected circumference was 11.46 cm. Penile dimensions are found to be correlated with anthropometric parameters. Insight into the normative data of penile size of Indian males obtained. There are significant differences in the mean penile length and circumference of Indian sample compared to the data reported from other countries. Study need to be continued with a large sample to establish a normative data applicable to the general population.

  19. Pole lengths influence O2-cost during double poling in highly trained cross-country skiers.

    PubMed

    Carlsen, Camilla Høivik; Rud, Bjarne; Myklebust, Håvard; Losnegard, Thomas

    2018-02-01

    In elite cross-country skiing, double poling is used in different terrain. This study compared O 2 -cost and kinematics during double poling with four different pole lengths [self-selected (SS), SS - 5 cm, SS + 5 cm, SS + 10 cm] at Low versus Moderate incline. Thirteen highly trained male cross-country skiers (mean ± SD 23 ± 3 years; 182 ± 4 cm; 77 ± 6 kg) completed eight submaximal trials with roller skis on a treadmill at two conditions: "Low incline" (1.7°; 4.5 m s -1 ) and "Moderate incline" (4.5°; 2.5 m s -1 ) with each of the four pole lengths. O 2 -cost and 3D body kinematics were assessed in each trial. In Low incline, SS + 10 cm induced a lower O 2 -cost than all the other pole lengths [P < 0.05; effect size (ES) 0.5-0.8], whereas no differences were found between the remaining pole lengths (P > 0.05; ES 0.2-0.4). In Moderate incline, significant differences between all pole lengths were found for O 2 -cost, with SS - 5 cm > SS > SS + 5 cm > SS + 10 cm (P < 0.05; ES 0.6-1.8). The relative differences in O 2 -cost between SS and the other pole lengths were greater in Moderate incline than Low incline (SS - 5 cm; 1.5%, ES 0.8, SS + 5 cm; 1.3%, ES 1.0, and SS + 10 cm; 1.9%, ES 1.0, all P < 0.05). No difference was found in cycle, poling or reposition times between pole lengths. However, at both conditions a smaller total vertical displacement of center of mass was observed with SS + 10 cm compared to the other pole lengths. Increasing pole length from SS - 5 cm to SS + 10 cm during double poling induced lower O 2 -cost and this advantage was greater in Moderate compared to Low incline.

  20. Behavioral study of ultradian activity periods of mice enclosed in experimental cages of different dimensions

    NASA Technical Reports Server (NTRS)

    Guillot, A.

    1982-01-01

    Male mice are enclosed in cages of different dimensions (cage A - 23x8x8 cm., cage B - 36x27x17 cm.), in an alternating light/dark regimen, at an ambient temperature of 22 to 23 C. The successions of the behavioral sequences of ultradian activity periods are noticed by direct observation during 11 consecutive hours in light. The experimental situation modifies the mean duration time and the behavioral organization of each activity period. However, the comparison of the overall activity time lengths and the comparison of the overall behavioral frequencies suggest that the energy spent per mouse is constant.

  1. Determination of carrier diffusion length in GaN

    NASA Astrophysics Data System (ADS)

    Hafiz, Shopan; Zhang, Fan; Monavarian, Morteza; Avrutin, Vitaliy; Morkoç, Hadis; Özgür, Ümit; Metzner, Sebastian; Bertram, Frank; Christen, Jürgen; Gil, Bernard

    2015-01-01

    Diffusion lengths of photo-excited carriers along the c-direction were determined from photoluminescence (PL) and cross-sectional cathodoluminescence (CL) measurements in p- and n-type GaN epitaxial layers grown on c-plane sapphire by metal-organic chemical vapor deposition. The investigated samples incorporate a 6 nm thick In0.15Ga0.85N active layer capped with either 500 nm p-GaN or 1500 nm n-GaN. The top GaN layers were etched in steps and PL from the InGaN active region and the underlying layers was monitored as a function of the top GaN thickness upon photo-generation near the surface region by above bandgap excitation. Taking into consideration the absorption in the top GaN layer as well as active and underlying layers, the diffusion lengths at 295 K and at 15 K were measured to be 93 ± 7 nm and 70 ± 7 nm for Mg-doped p-type GaN and 432 ± 30 nm and 316 ± 30 nm for unintentionally doped n-type GaN, respectively, at photogenerated carrier densities of 4.2 × 1018 cm-3 using PL spectroscopy. CL measurements of the unintentionally doped n-type GaN layer at much lower carrier densities of 1017 cm-3 revealed a longer diffusion length of 525 ± 11 nm at 6 K.

  2. Shortened penis post penile prosthesis implantation treated with subcutaneous soft silicone penile implant: case report.

    PubMed

    Shirvanian, V; Lemperle, G; Araujo Pinto, C; Elist, J J

    2014-01-01

    Penile prosthesis surgery for erectile dysfunction has the highest satisfaction rates among all treatment options but is often associated with subjective and objective loss of penile length and girth following surgery. To present a novel technique using a subcutaneous soft silicone implant for reversal of penile shortening and narrowing after prosthesis surgery, with additional gains in overall penile length and girth. Nine patients were treated with the insertion of a subcutaneous soft silicone penile implant. All patients had previously reported a loss in penile length (0.5-2 cm), and seven of nine patients also reported a loss in penile girth (0.5-2.6 cm) after penile prosthesis surgery. During a follow-up period of 4-24 months, penile length and girth measurements showed a mean increase in length of 2.4 cm (±0.75 cm) and a mean increase in girth of 3.4 cm (±0.94 cm). The additional insertion of a subcutaneous soft silicone implant in patients with decreased penile length and girth after penile prosthesis surgery is an effective treatment option that provides reversal of lost penile length and girth.

  3. Dual active layer a-IGZO TFT via homogeneous conductive layer formation by photochemical H-doping

    PubMed Central

    2014-01-01

    In this study, InGaZnO (IGZO) thin film transistors (TFTs) with a dual active layer (DAL) structure are fabricated by inserting a homogeneous embedded conductive layer (HECL) in an amorphous IGZO (a-IGZO) channel with the aim of enhancing the electrical characteristics of conventional bottom-gate-structure TFTs. A highly conductive HECL (carrier concentration at 1.6 × 1013 cm-2, resistivity at 4.6 × 10-3 Ω∙cm, and Hall mobility at 14.6 cm2/Vs at room temperature) is fabricated using photochemical H-doping by irradiating UV light on an a-IGZO film. The electrical properties of the fabricated DAL TFTs are evaluated by varying the HECL length. The results reveal that carrier mobility increased proportionally with the HECL length. Further, a DAL TFT with a 60-μm-long HECL embedded in an 80-μm-long channel exhibits comprehensive and outstanding improvements in its electrical properties: a saturation mobility of 60.2 cm2/Vs, threshold voltage of 2.7 V, and subthreshold slope of 0.25 V/decade against the initial values of 19.9 cm2/Vs, 4.7 V, and 0.45 V/decade, respectively, for a TFT without HECL. This result confirms that the photochemically H-doped HECL significantly improves the electrical properties of DAL IGZO TFTs. PMID:25435832

  4. Dual active layer a-IGZO TFT via homogeneous conductive layer formation by photochemical H-doping.

    PubMed

    Jeong, Seung-Ki; Kim, Myeong-Ho; Lee, Sang-Yeon; Seo, Hyungtak; Choi, Duck-Kyun

    2014-01-01

    In this study, InGaZnO (IGZO) thin film transistors (TFTs) with a dual active layer (DAL) structure are fabricated by inserting a homogeneous embedded conductive layer (HECL) in an amorphous IGZO (a-IGZO) channel with the aim of enhancing the electrical characteristics of conventional bottom-gate-structure TFTs. A highly conductive HECL (carrier concentration at 1.6 × 10(13) cm(-2), resistivity at 4.6 × 10(-3) Ω∙cm, and Hall mobility at 14.6 cm(2)/Vs at room temperature) is fabricated using photochemical H-doping by irradiating UV light on an a-IGZO film. The electrical properties of the fabricated DAL TFTs are evaluated by varying the HECL length. The results reveal that carrier mobility increased proportionally with the HECL length. Further, a DAL TFT with a 60-μm-long HECL embedded in an 80-μm-long channel exhibits comprehensive and outstanding improvements in its electrical properties: a saturation mobility of 60.2 cm(2)/Vs, threshold voltage of 2.7 V, and subthreshold slope of 0.25 V/decade against the initial values of 19.9 cm(2)/Vs, 4.7 V, and 0.45 V/decade, respectively, for a TFT without HECL. This result confirms that the photochemically H-doped HECL significantly improves the electrical properties of DAL IGZO TFTs.

  5. Active Protection of an MgB2 Test Coil

    PubMed Central

    Park, Dong Keun; Hahn, Seungyong; Bascuñán, Juan; Iwasa, Yukikazu

    2011-01-01

    This paper presents results of a study, experimental and computational, of a detect-and-activate-the-heater protection technique applied to a magnesium diboride (MgB2) test coil operated in semi-persistent mode. The test coil with a winding ID of 25 cm and wound with ~500-m long reacted MgB2 wire was operated at 4.2 K immersed in a bath of liquid helium. In this active technique, upon the initiation of a “hot spot” of a length ~10 cm, induced by a “quench heater,” a “protection heater” (PH) of ~600-cm long planted within the test coil is activated. The normal zone created by the PH is large enough to absorb the test coil’s entire initial stored energy and still keeps the peak temperature within the winding below ~260 K. PMID:22081754

  6. Properties of coronal arches

    NASA Technical Reports Server (NTRS)

    Davis, J. M.; Krieger, A. S.

    1982-01-01

    The properties of coronal arches located on the peripheries of active regions, observed during a sounding rocket flight on March 8, 1973, are discussed. The arches are found to overlie filament channels and their footpoints are traced on locations on the perimeters of supergranulation cells. The arches have a wide range of lengths although their widths are well approximated by the value 2.2 x 10 to the 9th cm. Comparison of the size of the chromospheric footprint with the arc width indicates that arches do not always expand as they ascend into the corona. The electron temperatures and densities of the plasma contained in the arches were measured and the pressure calculated; typical values are 2-million K, 1 x 10 to the 9th/cu cm, and 0.2 dyne/sq cm, respectively. The variation of these parameters with position along the length of the arch indicates that the arches are not in hydrostatic equilibrium.

  7. Vascular geometry of the extracranial carotid arteries: an analysis of length, diameter, and tortuosity.

    PubMed

    Choudhry, Farooq A; Grantham, John T; Rai, Ansaar T; Hogg, Jeffery P

    2016-05-01

    Stable access is essential for successful intracranial interventions. Quantifying variations in extracranial carotid arteries may help in the selection and development of access catheters. This study describes the vascular dimensions from the aortic arch to the skull base. CT angiography analysis was performed on 100 patients. The lengths, diameters, and tortuosity of the common carotid artery (CCA) and internal carotid artery (ICA) were measured from the aortic arch to the skull base. The mean±SD length of the carotid artery from the aortic arch to the skull base was 22.2±2.2 cm for the right side and 20.8±1.9 cm for the left side (p<0.0001). The length of the right CCA was 13.6±1.2 cm and the length of the left CCA was 12.4±1.4 cm (p<0.0001). The length of the right ICA was 8.6±1.4 cm compared with 8.4±1.4 cm for the left ICA (p=0.3). The ICA length in men and women was 8.9±1.3 cm and 8.2±1.3 cm, respectively (p=0.0001), and the CCA length in men and women was 13.6±1.5 cm and 12.3±1.6 cm, respectively (p<0.0001). The lengths of the CCA and ICA in patients aged ≥60 years were 13.3±1.7 cm and 8.9±1.5 cm, respectively compared with 12.8±1.7 cm and 8.2±1.1 cm, respectively, for patients aged <60 years (p=0.04 for CCA, p=0.0002 for ICA). Tortuosity of the CCA and ICA was 1.2±0.2 and 1.3±0.1, respectively, in patients aged ≥60 years compared with 1.1±0.1 for both the ICA and CCA in patients aged <60 years (p<0.0001 for both). There was a consistent ratio of CCA/ICA length of 1.6±0.3 on the right and 1.5±0.3 on the left (p<0.0001). The arterial diameters did not show any significant difference. The distance from the aortic arch to the skull base is longer on the right than on the left side. Both the CCA and ICA are longer in men and in patients aged ≥60 years. The tortuosity of both segments significantly increases with age. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Axial deformity correction in children via distraction osteogenesis.

    PubMed

    Antoci, Valentin; Ono, Craig M; Antoci, Valentin; Raney, Ellen M

    2006-08-01

    We performed a retrospective analysis of the results of 62 tibial and 54 femoral lengthenings in 88 consecutive patients. The patients mean age was 13.5 years and mean follow-up was four years. There was a significant difference between metaphyseal (27+/-1.2 days/cm) and diaphyseal (39.4+/-1.7 days/cm), tibial (34+/-1.7 days/cm) and femoral (31+/-1.4 days/cm) lengthening (P<0.05), but no significant difference among the lengthening indexes when treating one-, two-, or three-dimensional deformities, congenital (34+/-2.4 days/cm) and acquired (32+/-1.0 days/cm) limb length discrepancy (LLD) (P>0.05). The lengthening index was 33+/-1.1 days/cm, distraction regenerate length 6+/-0.4 cm, and lengthening percentage 21+/-2.1. The scatter plots of new regenerate length against time and the scatter plots of neurological complication, residual deformities, broken pins, joint contractures, and hypertension rate against lengthening percentage showed a positive linear relationship (r=0.8). We found the correlations between quantitative and qualitative parameters that should help to predict the treatment outcomes. Lengthening index depends on the amount of length gained. Higher length of new bone regenerate leads to a decrease in lengthening index. Expected gain in bone length can aid in estimating the duration of treatment. The lengthening percentage correlates very well with the complication rate and can be used to predict the complication rate.

  9. Motor units in the human medial gastrocnemius muscle are not spatially localized or functionally grouped.

    PubMed

    Héroux, Martin E; Brown, Harrison J; Inglis, J Timothy; Siegmund, Gunter P; Blouin, Jean-Sébastien

    2015-08-15

    Human medial gastrocnemius (MG) motor units (MUs) are thought to occupy small muscle territories or regions, with low-threshold units preferentially located distally. We used intramuscular recordings to measure the territory of muscle fibres from MG MUs and determine whether these MUs are grouped by recruitment threshold or joint action (ankle plantar flexion and knee flexion). The territory of MUs from the MG muscle varied from somewhat localized to highly distributed, with approximately half the MUs spanning at least half the length and width of the muscle. There was also no evidence of regional muscle activity based on MU recruitment thresholds or joint action. The CNS does not have the means to selectively activate regions of the MG muscle based on task requirements. Human medial gastrocnemius (MG) motor units (MUs) are thought to occupy small muscle territories, with low-threshold units preferentially located distally. In this study, subjects (n = 8) performed ramped and sustained isometric contractions (ankle plantar flexion and knee flexion; range: ∼1-40% maximal voluntary contraction) and we measured MU territory size with spike-triggered averages from fine-wire electrodes inserted along the length (seven electrodes) or across the width (five electrodes) of the MG muscle. Of 69 MUs identified along the length of the muscle, 32 spanned at least half the muscle length (≥ 6.9 cm), 11 of which spanned all recording sites (13.6-17.9 cm). Distal fibres had smaller pennation angles (P < 0.05), which were accompanied by larger territories in MUs with fibres located distally (P < 0.05). There was no distal-to-proximal pattern of muscle activation in ramp contraction (P = 0.93). Of 36 MUs identified across the width of the muscle, 24 spanned at least half the muscle width (≥ 4.0 cm), 13 of which spanned all recording sites (8.0-10.8 cm). MUs were not localized (length or width) based on recruitment threshold or contraction type, nor was there a relationship between MU territory size and recruitment threshold (Spearman's rho = -0.20 and 0.13, P > 0.18). MUs in the human MG have larger territories than previously reported and are not localized based on recruitment threshold or joint action. This indicates that the CNS does not have the means to selectively activate regions of the MG muscle based on task requirements. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

  10. Does smooth muscle in an intact airway undergo length adaptation during a sustained change in transmural pressure?

    PubMed

    Ansell, Thomas K; McFawn, Peter K; McLaughlin, Robert A; Sampson, David D; Eastwood, Peter R; Hillman, David R; Mitchell, Howard W; Noble, Peter B

    2015-03-01

    In isolated airway smooth muscle (ASM) strips, an increase or decrease in ASM length away from its current optimum length causes an immediate reduction in force production followed by a gradual time-dependent recovery in force, a phenomenon termed length adaptation. In situ, length adaptation may be initiated by a change in transmural pressure (Ptm), which is a primary physiological determinant of ASM length. The present study sought to determine the effect of sustained changes in Ptm and therefore, ASM perimeter, on airway function. We measured contractile responses in whole porcine bronchial segments in vitro before and after a sustained inflation from a baseline Ptm of 5 cmH2O to 25 cmH2O, or deflation to -5 cmH2O, for ∼50 min in each case. In one group of airways, lumen narrowing and stiffening in response to electrical field stimulation (EFS) were assessed from volume and pressure signals using a servo-controlled syringe pump with pressure feedback. In a second group of airways, lumen narrowing and the perimeter of the ASM in situ were determined by anatomical optical coherence tomography. In a third group of airways, active tension was determined under isovolumic conditions. Both inflation and deflation reduced the contractile response to EFS. Sustained Ptm change resulted in a further decrease in contractile response, which returned to baseline levels upon return to the baseline Ptm. These findings reaffirm the importance of Ptm in regulating airway narrowing. However, they do not support a role for ASM length adaptation in situ under physiological levels of ASM lengthening and shortening. Copyright © 2015 the American Physiological Society.

  11. Effects of horizontal vs vertical vaginal cuff closure techniques on vagina length after vaginal hysterectomy: a prospective randomized study.

    PubMed

    Cavkaytar, Sabri; Kokanali, Mahmut Kuntay; Topcu, Hasan Onur; Aksakal, Orhan Seyfi; Doganay, Melike

    2014-01-01

    To compare the effects of horizontal and vertical vaginal cuff closure techniques on vagina length after vaginal hysterectomy. Prospective randomized study (Canadian Task Force classification I). Teaching and research hospital, a tertiary center. Fifty-two women with POP-Q stage 0 or 1 uterine prolapse were randomized into 2 groups using vertical (n = 26) or horizontal (n = 26) vaginal cuff closure. All patients underwent vaginal hysterectomy. Vagina length in the 2 groups was compared preoperatively, immediately after surgery, and at 6 weeks postoperatively. Mean (SD) preoperative vagina length in the horizontal and vertical groups was similar (7.87 [0.92] cm vs 7.99 [0.78] cm; p = .41). Immediately postoperatively, the vagina was significantly shorter in the horizontal group than in the vertical group (6.61 [0.89] cm vs 7.51 [0.74] cm; p < .001). At 6 weeks postoperatively, the vagina was still significantly shorter in the horizontal group (6.55 [0.89] cm vs 7.42 (0.73) cm; p < .001). The mean difference in vagina length before and after surgery was also significantly higher in the horizontal group than in the vertical group (-1.26 [0.12] cm vs 0.49 [0.11] cm; p < .001). Vertical cuff closure during vaginal hysterectomy seems to preserve vagina length better than does horizontal cuff closure. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  12. CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Xinhua; Zhang, Da; Liu, Bob, E-mail: bliu7@mgh.harvard.edu

    2015-06-15

    Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D{sub L}(0) and its rise-to-the-equilibrium curve H(L) = D{sub L}(0)/D{sub eq} from computed tomography (CT) scanning, where D{sub eq} is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessedmore » H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm{sup 3} thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E{sub in}/E or E{sub out}/E) on the phantom central and peripheral axes, where E = LD{sub eq} was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose ratios changed with beam aperture and phantom axis but were insensitive to tube voltage. H(L) was insensitive to tube voltage and CT scanner model. As phantom diameter increased from 6 to 55 cm, E{sub in}/E generally decreased but asymptotically approached constant levels on the peripheral axes of large phantoms. The curve of E{sub in}/E versus scan length was almost identical to that of H(L). Similarly, E{sub out}/E increased with scan length and asymptotically approached the equilibrium for large scan lengths. E{sub out}/D{sub eq} was much less than the equilibrium length L{sub eq} where H(L) = 0.98, even with scan lengths much larger than L{sub eq}. Conclusions: The polyethylene phantom designed by ICRU Report No. 87 Committee and AAPM Task Group 200 is adequately long for assessing the midpoint dose and its equilibration in CT scanning. The short-to-long phantom dose ratios and the H(L) data provided in this paper allow easy evaluations of the midpoint dose, longitudinal dose distribution, and energy absorption in polyethylene phantoms. The results of dose equilibration and energy absorption presented herein may be insightful for the clinical CT scans with various subject sizes and scan lengths.« less

  13. Physiological cross-sectional area of human leg muscles based on magnetic resonance imaging

    NASA Technical Reports Server (NTRS)

    Fukunaga, T.; Roy, R. R.; Shellock, F. G.; Hodgson, J. A.; Day, M. K.; Lee, P. L.; Kwong-Fu, H.; Edgerton, V. R.

    1992-01-01

    Magnetic resonance imaging techniques were used to determine the physiological cross-sectional areas (PCSAs) of the major muscles or muscle groups of the lower leg. For 12 healthy subjects, the boundaries of each muscle or muscle group were digitized from images taken at 1-cm intervals along the length of the leg. Muscle volumes were calculated from the summation of each anatomical CSA (ACSA) and the distance between each section. Muscle length was determined as the distance between the most proximal and distal images in which the muscle was visible. The PCSA of each muscle was calculated as muscle volume times the cosine of the angle of fiber pinnation divided by fiber length, where published fiber length:muscle length ratios were used to estimate fiber lengths. The mean volumes of the major plantarflexors were 489, 245, and 140 cm3 for the soleus and medial (MG) and lateral (LG) heads of the gastrocnemius. The mean PCSA of the soleus was 230 cm2, about three and eight times larger than the MG (68 cm2) and LG (28 cm2), respectively. These PCSA values were eight (soleus), four (MG), and three (LG) times larger than their respective maximum ACSA. The major dorsiflexor, the tibialis anterior (TA), had a muscle volume of 143 cm2, a PCSA of 19 cm2, and an ACSA of 9 cm2. With the exception of the soleus, the mean fiber length of all subjects was closely related to muscle volume across muscles. The soleus fibers were unusually short relative to the muscle volume, thus potentiating its force potential.(ABSTRACT TRUNCATED AT 250 WORDS).

  14. PERINEAL BODY STRETCH DURING LABOR DOES NOT PREDICT PERINEAL LACERATION, POSTPARTUM INCONTINENCE, OR POSTPARTUM SEXUAL FUNCTION: A COHORT STUDY

    PubMed Central

    MERIWETHER, Kate V.; ROGERS, Rebecca G.; DUNIVAN, Gena C.; ALLDREDGE, Jill K.; QUALLS, Clifford; MIGLIACCIO, Laura; LEEMAN, Lawrence

    2017-01-01

    Introduction The perineum stretches naturally during obstetrical labor, but it is unknown if this stretch has a negative impact on pelvic floor outcomes after a vaginal birth (VB). We aimed to evaluate whether perineal stretch was associated with postpartum pelvic floor dysfunction. Materials and Methods This was a prospective cohort study of primiparous women who had a VB. Perineal body (PB) length was measured antepartum, during labor, and 6 months postpartum. We determined the maximum PB (PB Max) measurements during the second stage of labor and PB change (ΔPB) between time points. Women completed functional questionnaires and had a POP-Q exam 6 months postpartum. We analyzed the relationship of PB measurements to perineal lacerations and postpartum outcomes including urinary, anal, or fecal incontinence, sexual activity and function, and POP-Q measurements. Results 448 women with VB had a mean age of 24 ± 5.0 years and rare (5%) third or fourth degree lacerations. During the second stage of labor, 270/448 (60%) had perineal measurements. Mean antepartum PB length was 3.7 ± 0.8 cm with a maximum mean PB length (PB Max) during the second stage of 6.1 ± 1.5 cm, an increase of 65%. The change in PB length (ΔPB) from antepartum to 6 months postpartum was a net decrease (−0.39 ± 1.02 cm). PB at any time point and PB Max were not associated with perineal lacerations or outcomes postpartum (all p>0.05). Discussion PB stretch during labor is unrelated to perineal laceration or postpartum incontinence, sexual activity, or sexual function. PMID:26874524

  15. Effect aquadest-extracted Gloriosa superba seed as mutagen on morphology of Artemisia annua

    NASA Astrophysics Data System (ADS)

    Rahmawati, S. I.; Susilowati, A.; Yunus, A.; Widyastuti, Y.

    2018-03-01

    Gloriosa superba is a plant that contains colchicine in all parts of organs, especially in the seeds. Its extract is as a mutagen to produce plants with polyploid cells. Artemisia annua is a plant that produces active ingredients artemisinin as malarial drugs, hemorrhoids therapy, aromatherapy, antiviral, anticancer, and anti-bacterial. The aims of this research was to determine the effect aquadest-extracted Gloriosa superba seed as a mutagen to Artemisia annua morphology. Extraction of Gloriosa superba seeds obtained from Sukoharjo using maceration method with aquadest solvent (1: 1). The extracts were diluted (0, 25, 50, 75 and 100%) for Artemisia annua sprinkling with different times (0, 30, 60 and 90 minutes). Observations of morphology Artemisia annua included height, stem circumference, number of branches, number of leaves, leaf width and leaf length. The treatments did not affect plant morphology observation included height, stem circumference, number of branches, number of leaves, leaf width, and leaf length. The EB treatment (100%, 30 minutes) was higher (120 cm) than other. In all treatments stem circumference about 2.5 cm, number of branches ranged between 40-50, leaves width ranged 9-16c m, and leaf length ranged 8-15 cm.

  16. Best Stent Length Predicted by Simple CT Measurement Rather than Patient Height.

    PubMed

    Barrett, Keith; Foell, Kirsten; Lantz, Andrea; Ordon, Michael; Lee, Jason Y; Pace, Kenneth T; Honey, R John D'A

    2016-09-01

    Ureteral stent length is important, as stents that are too long might worsen symptoms and too short are at higher risk of migration. The purpose of this study was to determine if patient or radiologic parameters correlate with directly measured ureteral length and if directly measured ureteral length predicts proper stent positioning. During stent placement, ureteral length (ureteropelvic junction to ureterovesical junction distance) was directly measured by endoscopically viewing a ureteral catheter (with 1-cm marking) emanating from the ureteral orifice. A 22, 24, or 26 cm stent was chosen to be closest to the measured ureteral length. For ureters >26 cm, a 26 cm stent was chosen. Ends of an "ideally positioned" stent were fully curled in the renal pelvis and bladder, without crossing the bladder midline. Rates of ideal stent position were compared between patients with matching stent and ureteral lengths and those with stent lengths differing by ≥1 cm (mismatched). The measured ureteral length was correlated with patient height, L1-L5 height, and length measured on CT. Fifty-nine ureters from 57 patients were included. Height was reasonably correlated with L1-L5 height (Spearman correlation coefficient [rho] = 0.79), although both were poorly correlated with directly measured ureteral length (rho = 0.18 for height and 0.32 for lumbar height). Ureteral lengths measured on CT correlated well with direct measurement (rho = 0.63 for axial cuts and rho = 0.64 for coronal cuts). Matched stent length was associated with higher rates of ideal stent position than mismatched (100% vs 70.9%, p = 0.006). CT measurements, rather than height, correlate well with measured length and could be used to choose the appropriate stent length. Stents matching directly measured ureteral lengths are associated with high rates of ideal stent position.

  17. Diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women

    PubMed Central

    Alijahan, Rahele; Kordi, Masoumeh; Poorjavad, Munira; Ebrahimzadeh, Saeed

    2014-01-01

    Background: Dystocia is one of the important causes of maternal morbidity and mortality in low-income countries. This study was aimed to determine the diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women. Materials and Methods: This prospective cohort study was conducted on 447 nulliparous women who referred to Omolbanin hospital. Several maternal anthropometric measurements such as height, transverse and vertical diameters of Michaelis sacral rhomboid area, foot length, head circumference, vertebral and lower limb length, symphysio-fundal height, and abdominal girth were taken in cervical dilatation ≤ 5 cm. Labor progression was controlled by a researcher blind to these measurements. After delivery, the accuracy of individual and combined measurements in prediction of dystocia was analyzed. Dystocia was defined as cesarean section and vacuum or forceps delivery for abnormal progress of labor (cervical dilatation less than 1 cm/h in the active phase for 2 h, and during the second stage, beyond 2 h or fetal head descend less than 1 cm/h). Results: Among the different anthropometric measurements, transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm, maternal height ≤ 155 cm, height to symphysio-fundal height ratio ≤4.7, lower limb length ≤78 cm, and head circumference to height ratio ≥ 35.05 with accuracy of 81.2%, 68.2%, 65.5%, 63.3%, and 61.5%, respectively, were better predictors. The best predictor was obtained by combination of maternal height ≤155 cm or the transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm and Johnson's formula estimated fetal weight ≥3255 g, with an accuracy of 90.5%, sensitivity of 70%, and specificity of 93.7%. Conclusions: Combination of other anthropometric measurements and estimated fetal weight with maternal height in comparison to maternal height alone leads to a better predictor for dystocia. PMID:24554954

  18. Diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women.

    PubMed

    Alijahan, Rahele; Kordi, Masoumeh; Poorjavad, Munira; Ebrahimzadeh, Saeed

    2014-01-01

    Dystocia is one of the important causes of maternal morbidity and mortality in low-income countries. This study was aimed to determine the diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women. This prospective cohort study was conducted on 447 nulliparous women who referred to Omolbanin hospital. Several maternal anthropometric measurements such as height, transverse and vertical diameters of Michaelis sacral rhomboid area, foot length, head circumference, vertebral and lower limb length, symphysio-fundal height, and abdominal girth were taken in cervical dilatation ≤ 5 cm. Labor progression was controlled by a researcher blind to these measurements. After delivery, the accuracy of individual and combined measurements in prediction of dystocia was analyzed. Dystocia was defined as cesarean section and vacuum or forceps delivery for abnormal progress of labor (cervical dilatation less than 1 cm/h in the active phase for 2 h, and during the second stage, beyond 2 h or fetal head descend less than 1 cm/h). Among the different anthropometric measurements, transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm, maternal height ≤ 155 cm, height to symphysio-fundal height ratio ≤4.7, lower limb length ≤78 cm, and head circumference to height ratio ≥ 35.05 with accuracy of 81.2%, 68.2%, 65.5%, 63.3%, and 61.5%, respectively, were better predictors. The best predictor was obtained by combination of maternal height ≤155 cm or the transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm and Johnson's formula estimated fetal weight ≥3255 g, with an accuracy of 90.5%, sensitivity of 70%, and specificity of 93.7%. Combination of other anthropometric measurements and estimated fetal weight with maternal height in comparison to maternal height alone leads to a better predictor for dystocia.

  19. Laboratory on Legs: An Architecture for Adjustable Morphology with Legged Robots

    DTIC Science & Technology

    2012-04-01

    fit within the body of the robot. Additional capabilities will largely depend upon a given activity, and should be easily reconfigurable to maximize...mobile robots, the essential units of actuation, computation, and sensing must be designed to fit within the body of the robot. Additional...PackBot,36 among others. Two parallel rails, 40 cm long and spaced at a center-to-center distance of 14 cm, span the length of the each robot’s body

  20. Preliminary genetic linkage map of the abalone Haliotis diversicolor Reeve

    NASA Astrophysics Data System (ADS)

    Shi, Yaohua; Guo, Ximing; Gu, Zhifeng; Wang, Aimin; Wang, Yan

    2010-05-01

    Haliotis diversicolor Reeve is one of the most important mollusks cultured in South China. Preliminary genetic linkage maps were constructed with amplified fragment length polymorphism (AFLP) markers. A total of 2 596 AFLP markers were obtained from 28 primer combinations in two parents and 78 offsprings. Among them, 412 markers (15.9%) were polymorphic and segregated in the mapping family. Chi-square tests showed that 151 (84.4%) markers segregated according to the expected 1:1 Mendelian ratio ( P<0.05) in the female parent, and 200 (85.8%) in the male parent. For the female map, 179 markers were used for linkage analysis and 90 markers were assigned to 17 linkage groups with an average interval length of 25.7 cm. For the male map, 233 markers were used and 94 were mapped into 18 linkage groups, with an average interval of 25.0 cm. The estimated genome length was 2 773.0 cm for the female and 2 817.1 cm for the male map. The observed length of the linkage map was 1 875.2 cm and 1 896.5 cm for the female and male maps, respectively. When doublets were considered, the map length increased to 2 152.8 cm for the female and 2 032.7 cm for the male map, corresponding to genome coverage of 77.6% and 72.2%, respectively.

  1. Crustal dynamics project session 4 validation and intercomparison experiments 1979-1980 report

    NASA Technical Reports Server (NTRS)

    Liebrecht, P.; Kolenkiewicz, R.; Ryan, J.; Hothem, L.

    1983-01-01

    As part of the Crustal Dynamics Project, an experiment was performed to verify the ability of Satellite Laser Ranging (SLR), Very Long Baseline interferometry (VLBI) and Doppler Satellite Positioning System (Doppler) techniques to estimate the baseline distances between several locations. The Goddard Space Flight Center (GSFC) lasers were in operation at all five sites available to them. The ten baselines involved were analyzed using monthly orbits and various methods of selecting data. The standard deviation of the monthly SLR baseline lengths was at the 7 cm level. The GSFC VLBI (Mark III) data was obtained during three separate experiments. November 1979 at Haystack and Owens Valley, and April and July 1980 at Haystack, Owens Valley, and Fort Davis. Repeatability of the VLBI in determining baseline lengths was calculated to be at the 2 cm level. Jet Propulsion Laboratory (JPL) VLBI (Mark II) data was acquired on the Owens Valley to Goldstone baseline on ten occasions between August 1979 and November 1980. The repeatability of these baseline length determinations was calculated to be at the 5 cm level. National Geodetic Survey (NGS) Doppler data was acquired at all five sites in January 1980. Repeatability of the Doppler determined baseline lengths results were calculated at approximately 30 cm. An intercomparison between baseline distances and associated parameters was made utilizing SLR, VLBI, and Doppler results on all available baselines. The VLBI and SLR length determinations were compared on four baselines with a resultant mean difference of -1 cm and a maximum difference of 12 cm. The SLR and Doppler length determinations were compared on ten baselines with a resultant mean difference of about 30 cm and a maximum difference of about 60 cm. The VLBI and Doppler lengths from seven baselines showed a resultant mean difference of about 30 cm and maximum difference of about 1 meter. The intercomparison of baseline orientation parameters were consistent with past analysis.

  2. Analysis of the age of Panax ginseng based on telomere length and telomerase activity.

    PubMed

    Liang, Jiabei; Jiang, Chao; Peng, Huasheng; Shi, Qinghua; Guo, Xiang; Yuan, Yuan; Huang, Luqi

    2015-01-23

    Ginseng, which is the root of Panax ginseng (Araliaceae), has been used in Oriental medicine as a stimulant and dietary supplement for more than 7,000 years. Older ginseng plants are substantially more medically potent, but ginseng age can be simulated using unscrupulous cultivation practices. Telomeres progressively shorten with each cell division until they reach a critical length, at which point cells enter replicative senescence. However, in some cells, telomerase maintains telomere length. In this study, to determine whether telomere length reflects ginseng age and which tissue is best for such an analysis, we examined telomerase activity in the main roots, leaves, stems, secondary roots and seeds of ginseng plants of known age. Telomere length in the main root (approximately 1 cm below the rhizome) was found to be the best indicator of age. Telomeric terminal restriction fragment (TRF) lengths, which are indicators of telomere length, were determined for the main roots of plants of different ages through Southern hybridization analysis. Telomere length was shown to be positively correlated with plant age, and a simple mathematical model was formulated to describe the relationship between telomere length and age for P. ginseng.

  3. 16 CFR 1220.1 - Scope, compliance dates, and definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...; (iii) Has an interior length dimension either greater than 139.7 cm (55 in.) or smaller than 126.3 cm (49 3/4 in.), or, an interior width dimension either greater than 77.7 cm (305/8 in.) or smaller than... crib—a non-full-size baby crib with an interior length dimension smaller than 126.3 cm (493/4 in.), or...

  4. The natural history of penile length after radical prostatectomy: a long-term prospective study.

    PubMed

    Vasconcelos, Juliana Souza; Figueiredo, Rui Teófilo; Nascimento, Fabio Luis Branco; Damião, Ronaldo; da Silva, Eloisio Alexsandro

    2012-12-01

    To describe the penile length after radical prostatectomy (RP) in a long-term follow-up. We evaluated prospectively the penile length of 105 patients with localized prostate cancer treated by open RP. Participants using therapy for penile rehabilitation were excluded from statistical analysis. Measurements of the stretched penis were taken preoperatively and at 3, 6, 12, 24, 36, 48, and 60 months postoperatively. The International Index of Erectile Function-Erectile Function (IIEF-EF) questionnaire was used to evaluate erectile function. The penile anthropometric measure used was the stretched length of the flaccid penis, from the pubopenile skin angle to the end of the glans, after the prepubic fat was depressed under maximum manual traction. The mean stretched penile length 3 months after RP decreased an average of 1 cm from baseline (P <.001). This mean difference persisted until 24 months. At 36 months, the penile length differed 0.6 cm. At 48 months (-0.3 cm) and 60 months (+0.4 cm), the mean differences in penile length before and after RP were not significant (P = .080 and P = .065, respectively). Erectile function was a predictor for early return of penile length. Nearly 1 cm of penile shortening after RP may be expected up to 12 months. However, a trend toward recovery of penile length occurs after 24 months of follow-up and is completely re-established after 48 months. The preserved erectile function after RP is a predictor for penile length recovery. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. SU-F-J-48: Effect of Scan Length On Magnitude of Imaging Dose in KV CBCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deshpande, S; Naidu, S; Sutar, A

    Purpose: To study effect of scan length on magnitude of imaging dose deposition in Varian kV CBCT for head & neck and pelvis CBCT. Methods: To study effect of scan length we measured imaging dose at depth of 8 cm for head and neck Cone Beam Computed Tomography (CBCT) acquisition ( X ray beam energy is used 100kV and 200 degree of gantry rotation) and at 16 cm depth for pelvis CBCT acquisition ( X ray beam energy used is 125 kV and 360 degree of gantry rotation) in specially designed phantom. We used farmer chamber which was calibrated inmore » kV X ray range for measurements .Dose was measured with default field size, and reducing field size along y direction to 10 cm and 5 cm. Results: As the energy of the beam decreases the scattered radiation increases and this contributes significantly to the dose deposited in the patient. By reducing the scan length to 10 Cm from default 20.6 cm we found a dose reduction of 14% for head and neck CBCT protocol and a reduction of 26% for pelvis CBCT protocol. Similarly for a scan length of 5cm compared to default the dose reduction in head and neck CBCT protocol is 36% while in the pelvis CBCT protocol the dose reduction is 50%. Conclusion: By limiting the scan length we can control the scatter radiation generated and hence the dose to the patient. However the variation in dose reduction for same length used in two protocols is because of the scan geometry. The pelvis CBCT protocol uses a full rotation and head and neck CBCT protocol uses partial rotation.« less

  6. Potential of solar-simulator-pumped alexandrite lasers

    NASA Technical Reports Server (NTRS)

    Deyoung, Russell J.

    1990-01-01

    An attempt was made to pump an alexandrite laser rod using a Tamarak solar simulator and also a tungsten-halogen lamp. A very low optical laser cavity was used to achieve the threshold minimum pumping-power requirement. Lasing was not achieved. The laser threshold optical-power requirement was calculated to be approximately 626 W/sq cm for a gain length of 7.6 cm, whereas the Tamarak simulator produces 1150 W/sq cm over a gain length of 3.3 cm, which is less than the 1442 W/sq cm required to reach laser threshold. The rod was optically pulsed with 200 msec pulses, which allowed the alexandrite rod to operate at near room temperature. The optical intensity-gain-length product to achieve laser threshold should be approximately 35,244 solar constants-cm. In the present setup, this product was 28,111 solar constants-cm.

  7. SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, X; Yang, K; Liu, B

    Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length wasmore » used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.« less

  8. Customization of biliopancreatic limb length to modulate and sustain antidiabetic effect of gastric bypass surgery.

    PubMed

    Pal, A; Rhoads, D B; Tavakkoli, A

    2018-02-01

    Although Roux-en-Y Gastric Bypass (RYGB) remains the most effective treatment for obesity and type 2 diabetes (T2D), many patients fail to achieve remission, or relapse. Increasing intestinal limb lengths of RYGB may improve outcomes, but the mechanistic basis for this remains unclear. We hypothesize biliopancreatic (BP) limb length modulates the antidiabetic effect of RYGB. Rats underwent RYGB with a 20-cm (RYGB-20cm) or 40-cm (RYGB-40cm) BP limb and were compared with control animals. After 2 and 4 wk, portal and systemic blood was sampled during intestinal glucose infusion. Portosystemic gradient was used to calculate intestinal glucose utilization (G util ), absorption (G absorp ), and hormone secretion. Intestinal morphology and gene expression were assessed. At 2 wk, G absorp progressively decreased with increasing BP limb length; this pattern persisted at 4 wk. G util increased ≈70% in both RYGB-20cm and -40cm groups at 2 wk. At 4 wk, G util progressively increased with limb length. Furthermore, Roux limb weight, and expression of hexokinase and preproglucagon, exhibited a similar progressive increase. At 4 wk, glucagon-like peptide-1 and -2 levels were higher after RYGB-40cm, with associated increased secretion. We conclude that BP limb length modulates multiple antidiabetic mechanisms, analogous to the dose-response relationship of a drug. Early postoperatively, a longer BP limb reduces G absorp . Later, G util , Roux limb hypertrophy, hormone secretion, and hormone levels are increased with longer BP limb. Sustained high incretin levels may prevent weight regain and T2D relapse. These data provide the basis for customizing BP limb length according to patient characteristics and desired metabolic effect. NEW & NOTEWORTHY Biliopancreatic limb length in gastric bypass modulates multiple antidiabetic mechanisms, analogous to the dose-response relationship of a drug. With a longer biliopancreatic limb, Roux limb hypertrophy, increased glucose utilization, reduced glucose absorption, and sustained high incretin levels may prevent weight regain and diabetes relapse.

  9. A simple on-line arterial time-activity curve detector for [O-15] water PET studies

    NASA Astrophysics Data System (ADS)

    Wollenweber, S. D.; Hichwa, R. D.; Ponto, L. L. B.

    1997-08-01

    A simple, automated on-line detector system has been fabricated and implemented to detect the arterial time-activity curve (TAG) for bolus-injection [O-15] water PET studies. This system offers two significant improvements over existing systems: a pump mechanism is not required to control arterial blood flow through the detector and dispersion correction of the time-activity curve for dispersion in external tubing is unnecessary. The [O-15] positrons emanating from blood within a thin-walled, 0.134 cm inner-diameter plastic tube are detected by a 0.5 cm wide by 1.0 cm long by 0.1 cm thick plastic scintillator mounted to a miniature PMT. Photon background is reduced to insignificant levels by a 2.0 cm thick cylindrical lead shield. Mean cerebral blood flow (mCBF) determined from an autoradiographic model and from the TAC measured by 1-second automated sampling was compared to that calculated from a TAC acquired using 5-second integrated manual samples. Improvements in timing resolution (1-sec vs. 5-sec) cause small but significant differences between the two sampling methods. Dispersion is minimized due to small tubing diameters, short lengths of tubing between the radial arterial sampling site and the detector and the presence of a 3-way valve 10 cm proximal to the detector.

  10. External hyphal production of vesicular-arbuscular mycorrhizal fungi in pasture and tallgrass prairie communities.

    PubMed

    Miller, R M; Jastrow, J D; Reinhardt, D R

    1995-07-01

    External hyphae of vesicular-arbuscular mycorrhizal (VAM) fungi were quantified over a growing season in a reconstructed tallgrass prairie and an ungrazed cool-season pasture. In both sites, hyphal lengths increased throughout the growing season. Peak external hyphal lengths were 111 m cm -3 of soil in the prairie and 81 m cm -3 of soil in the pasture. These hyphal lengths calculate to external hyphal dry weights of 457 μg cm -3 and 339 μg cm -3 of soil for prairie and pasture communities, respectively. The relationships among external hyphal length, root characteristics, soil P and soil moisture were also determined. Measures of gross root morphology [e.g., specific root length (SRL) and root mass] have a strong association with external hyphal length. Over the course of the study, both grassland communities experienced a major drought event in late spring. During this period a reduction in SRL occurred in both the pasture and prairie without a measured reduction in external hyphal length. Recovery for both the pasture and prairie occurred not by increasing SRL, but rather by increasing external hyphal length. This study suggests that growth is coordinated between VAM hyphae and root morphology, which in turn, are constrained by plant community composition and soil nutrient and moisture conditions.

  11. Effect of cane length and swing arc width on drop-off and obstacle detection with the long cane

    PubMed Central

    Kim, Dae Shik; Emerson, Robert Wall; Naghshineh, Koorosh

    2017-01-01

    A repeated-measures design with block randomization was used for the study, in which 15 adults with visual impairments attempted to detect the drop-offs and obstacles with the canes of different lengths, swinging the cane in different widths (narrow vs wide). Participants detected the drop-offs significantly more reliably with the standard-length cane (79.5% ± 6.5% of the time) than with the extended-length cane (67.6% ± 9.1%), p <.001. The drop-off detection threshold of the standard-length cane (4.1 ± 1.1 cm) was also significantly smaller than that of the extended-length cane (6.5±1.8cm), p <.001. In addition, participants detected drop-offs at a significantly higher percentage when they swung the cane approximately 3 cm beyond the widest part of the body (78.6% ± 7.6%) than when they swung it substantially wider (30 cm; 68.5% ± 8.3%), p <.001. In contrast, neither cane length (p =.074) nor cane swing arc width (p =.185) had a significant effect on obstacle detection performance. The findings of the study may help orientation and mobility specialists recommend appropriate cane length and cane swing arc width to visually impaired cane users. PMID:29276326

  12. Effect of cane length and swing arc width on drop-off and obstacle detection with the long cane.

    PubMed

    Kim, Dae Shik; Emerson, Robert Wall; Naghshineh, Koorosh

    2017-09-01

    A repeated-measures design with block randomization was used for the study, in which 15 adults with visual impairments attempted to detect the drop-offs and obstacles with the canes of different lengths, swinging the cane in different widths (narrow vs wide). Participants detected the drop-offs significantly more reliably with the standard-length cane (79.5% ± 6.5% of the time) than with the extended-length cane (67.6% ± 9.1%), p <.001. The drop-off detection threshold of the standard-length cane (4.1 ± 1.1 cm) was also significantly smaller than that of the extended-length cane (6.5±1.8cm), p <.001. In addition, participants detected drop-offs at a significantly higher percentage when they swung the cane approximately 3 cm beyond the widest part of the body (78.6% ± 7.6%) than when they swung it substantially wider (30 cm; 68.5% ± 8.3%), p <.001. In contrast, neither cane length ( p =.074) nor cane swing arc width ( p =.185) had a significant effect on obstacle detection performance. The findings of the study may help orientation and mobility specialists recommend appropriate cane length and cane swing arc width to visually impaired cane users.

  13. Ergonomics study on the handle length and lift angle for the culinary spatula.

    PubMed

    Wu, Swei-Pi; Hsieh, Chang-Sheng

    2002-09-01

    The culinary spatula (turning shovel) is one of the most common cooking tools used in the kitchen in Asia. However, the culinary spatula has seldom been ergonomically investigated. When a person uses a spatula to cook food, the operations involve repetitive bent-wrist motions, such as dorsiflexion, palmary flexion, and radial and ulnar deviations. These movements may cause cumulative trauma disorders in the upper extremities, and in particular carpal tunnel syndrome. A poorly designed culinary spatula will be ergonomically inefficient and cause injury to the hand and wrist. The purpose of this study was to investigate the effects of spatula handle length and lift angle on food-frying, food-turning, and food-shoveling performance. Eight female subjects were tested using 16 different culinary spatulas, with four different handle lengths (20, 25, 30 and 35 cm) and four different lift angles (15 degrees, 25 degrees, 35 degrees and 45 ). The criterion measures included cooking performance, and rating of perceived exertion. The subjects ranked their preference after all of the tasks in the tests were completed. The results showed that: (1) The handle length had a significant influence on the cooking performance, and rating of perceived exertion. The optimal handle lengths for frying food, turning food, and shoveling food were 20, 25 and 25 cm, respectively. (2) The lift angle significantly affected the cooking performance, and rating of perceived exertion. The optimal lift angles for frying food, turning food, and shoveling food were 15 degrees, 15 degrees and 25 degrees, respectively. (3) Both the handle length and lift angle had significant effects on subjective preference. For the handle length, the 20 cm length was the best. For the lift angle, the 25 angle was the best. (4) In general, a spatula with a 20 cm handle length and 25 degrees lift angle was the best. A spatula with a 25 cm handle length and 15 lift angle was the second most preferred. (5) However, to prevent subjects from touching the edge of a hot pan, a spatula with a 25 cm handle length and 25 lift angle is suggested.

  14. Optimal Guiding Catheter Length for Endovascular Coiling of Intracranial Aneurysms in Anterior Circulation in Era of Flourishing Distal Access System

    PubMed Central

    Jia, Zhen Yu; Lee, Sang Hun; Kim, Young Eun; Choi, Joon Ho; Hwang, Sun Moon; Lee, Ga Young; Youn, Jin Ho

    2017-01-01

    Purpose To determine the minimum required guiding catheter length for embolization of various intracranial aneurysms in anterior circulation and to analyze the effect of various patient factors on the required catheter length and potential interaction with its stability. Materials and Methods From December 2016 to March 2017, 90 patients with 93 anterior circulation aneurysms were enrolled. Three types of guiding catheters (Envoy, Envoy DA, and Envoy DA XB; Codman Neurovascular, Raynham, MA, USA) were used. We measured the in-the-body length of the catheter and checked the catheter tip location in the carotid artery. We analyzed factors affecting the in-the-body length and stability of the guiding catheter system. Results The average (±standard deviation) in-the-body length of the catheter was 84.2±5.9 cm. The length was significantly longer in men (89.1±5.6 vs. 82.1±4.6 cm, P<0.001), patients older than 65 years (87.7±7.8 vs. 82.7±4.2 cm, P<0.001), patients with a more tortuous arch (arch type 2 and 3) (87.5±7.4 vs. 82.7±4.4 cm, P<0.001), and patients with a distal aneurysm location (distal group) (86.2±5.0 vs. 82.7±6.1 cm, P=0.004). A shift in the tip location was noted in 19 patients (20.4%); there was no significant different among the 3 catheters (P=0.942). Conclusion The minimum required length of a guiding catheter was 84 cm on average for elective anterior-circulation aneurysm embolization. The length increased in men older than 65 years with a more tortuous arch. We could reach a higher position with distal access catheters with little difference in the stability once we reached the target location. PMID:28955511

  15. Dismantling of Radium-226 Coal Level Gauges: Encountered Problems and How to Solve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Punnachaiya, M.; Nuanjan, P.; Moombansao, K.

    2006-07-01

    This paper describes the techniques for dismantling of disused-sealed Radium-226 (Ra-226) coal level gauges which the source specifications and documents were not available, including problems occurred during dismantling stage and the decision making in solving all those obstacles. The 2 mCi (20 pieces), 6 mCi (20 pieces) and 6.6 mCi (30 pieces) of Ra-226 hemi-spherically-shaped with lead-filled coal level gauges were used in industrial applications for electric power generation. All sources needed to be dismantled for further conditioning as requested by the International Atomic Energy Agency (IAEA). One of the 2 mCi Ra-226 source was dismantled under the supervision ofmore » IAEA expert. Before conditioning period, each of the 6 mCi and 6.6 mCi sources were dismantled and inspected. It was found that coal level gauges had two different source types: the sealed cylindrical source (diameter 2 cm x 2 cm length) locked with spring in lead housing for 2 mCi and 6.6 mCi; while the 6 mCi was an embedded capsule inside source holder stud assembly in lead-filled housing. Dismantling Ra-226 coal level gauges comprised of 6 operational steps: confirmation of the surface dose rate on each source activity, calculation of working time within the effective occupational dose limit, cutting the weld of lead container by electrical blade, confirmation of the Ra-226 embedded capsule size using radiation scanning technique and gamma radiography, automatic sawing of the source holder stud assembly, and transferring the source to store in lead safe box. The embedded length of 6 mCi Ra-226 capsule in its diameter 2 cm x 14.7 cm length stud assembly was identified, the results from scanning technique and radiographic film revealed the embedded source length of about 2 cm, therefore all the 6 mCi sources were safely cut at 3 cm using the automatic saw. Another occurring problem was one of the 6.6 mCi spring type source stuck inside its housing because the spring was deformed and there was previously a leakage on inner source housing. Thus, during manufacturing the filled-lead for shielding passed through this small hole and fixed the deformed spring together with the source. The circular surface of inner hole was measured and slowly drilled at a diameter 2.2 cm behind shielding, till the spring and the fixed lead sheet were cut, therefore the source could be finally hammered out. The surface dose rate of coal level gauges before weld cutting was 10-15 mR/hr and the highest dose rate at the position of the weld cutter was 2.5 mR/hr. The total time for each weld cutting and automatic sawing was 2-3 minutes and 1 minute, respectively. The source was individually and safely transferred to store in lead safe box using a 1-meter length tong and a light container with 1 meter length handle. The total time for Ra-226 (70 pieces) dismantling, including the encountered problems and their troubles shooting took 4 days operation in which the total dose obtained by 18 operators were ranged from 1-38 {mu}Sv. The dismantling team safely completed the activities within the effective dose limit for occupational exposure of 20 mSv/year (80 {mu}Sv/day). (authors)« less

  16. Chain length effects of p-oligophenyls with comparison of benzene by Raman scattering

    NASA Astrophysics Data System (ADS)

    Zhang, Kai; Chen, Xiao-Jia

    2018-02-01

    Raman scattering measurements are performed on benzene and a number of p-oligophenyls including biphenyl, p-terphenyl, p-quaterphenyl, p-quinquephenyl, and p-sexiphenyl at ambient conditions. The vibrational modes of the intra- and intermolecular terms in these materials are analyzed and compared. Chain length effects on the vibrational properties are examined for the C-H in-plane bending mode and the inter-ring C-C stretching mode at around 1200 cm-1 and 1280 cm-1, respectively, and the C-C stretching modes at around 1600 cm-1. The complex and fluctuating properties of these modes result in an imprecise estimation of the chain length of these molecules. Meanwhile, the obtained ratio of the intensities of the 1200 cm-1 mode and 1280 cm-1 mode is sensitive to the applied lasers. A librational motion mode with the lowest energy is found to have a monotonous change with the increase in the chain length. This mode is simply relevant to the c axis of the unit cell. Such an obvious trend makes it a better indicator for determining the chain length effects on the physical and chemical properties in these molecules.

  17. Racial/ethnic variations in perineal length and association with perineal lacerations: a prospective cohort study.

    PubMed

    Yeaton-Massey, Amanda; Wong, Luchin; Sparks, Teresa N; Handler, Stephanie J; Meyer, Michelle R; Granados, Jesus M; Stasenko, Marina; Sit, Anita; Caughey, Aaron B

    2015-02-01

    To examine the association between race/ethnicity, perineal length and the risk of perineal laceration. This is a prospective cohort study of a diverse group of women with singleton gestations in the third trimester of pregnancy. Perineal length was measured and mean values calculated for several racial/ethnic groups. Chi-squared analyses were used to examine rates of severe perineal laceration (third or fourth degree laceration) by race/ethnicity among women considered to have a short perineal length. Further, subgroup analyses were performed comparing nulliparas to multiparas. Among 344 study participants, there was no statistically significant difference in mean perineal length by race/ethnicity (White 4.0 ± 1.1 cm, African-American 3.7 ± 1.0 cm, Latina 4.1 ± 1.1 cm, Asian 3.8 ± 1.0 cm, and other/unknown 4.0 ± 0.9 cm). Considering parity, more multiparous Asian and African-American women had a short perineal length (20.7 and 23.5%, respectively, p = 0.05). Finally, the rate of severe perineal lacerations in our cohort was 2.6% overall, but was 8.2% among Asian women (p = 0.04). We did not find a relationship between short perineal length and risk of severe perineal laceration with vaginal delivery, or a difference in mean perineal length by maternal race/ethnicity. However, we did find that women of different racial/ethnic groups have varying rates of severe perineal laceration, with Asian women comprising the highest proportion.

  18. A new large-volume metal reference standard for radioactive waste management.

    PubMed

    Tzika, F; Hult, M; Stroh, H; Marissens, G; Arnold, D; Burda, O; Kovář, P; Suran, J; Listkowska, A; Tyminski, Z

    2016-03-01

    A new large-volume metal reference standard has been developed. The intended use is for calibration of free-release radioactivity measurement systems and is made up of cast iron tubes placed inside a box of the size of a Euro-pallet (80 × 120 cm). The tubes contain certified activity concentrations of (60)Co (0.290 ± 0.006 Bq g(-1)) and (110m)Ag (3.05 ± 0.09 Bq g(-1)) (reference date: 30 September 2013). They were produced using centrifugal casting from a smelt into which (60)Co was first added and then one piece of neutron irradiated silver wire was progressively diluted. The iron castings were machined to the desirable dimensions. The final material consists of 12 iron tubes of 20 cm outer diameter, 17.6 cm inner diameter, 40 cm length/height and 245.9 kg total mass. This paper describes the reference standard and the process of determining the reference activity values. © The Author 2015. Published by Oxford University Press.

  19. Leg length, sitting height, and body proportions references for achondroplasia: New tools for monitoring growth.

    PubMed

    Del Pino, Mariana; Ramos Mejía, Rosario; Fano, Virginia

    2018-04-01

    Achondroplasia is the most common form of inherited disproportionate short stature. We report leg length, sitting height, and body proportion curves for achondroplasia. Seven centile format of sitting height, leg length, sitting height/leg length ratio, sitting height/height ratio, and head circumference/height ratio were estimated by the LMS method. The Q-test was applied to assess the goodness of fit. For comparison, centiles of sitting height and leg length were graphed using Argentine national growth references for achondroplasia and non-achondroplasia populations. The sample consisted of 342 children with achondroplasia (171 males, 171 females) aged 0-18 years. The median (interquartile range) number of measurements per child was 6 (3, 12) for sitting height and 8 (3, 13) for head circumference. Median leg length increased from 14 cm at age 1 week to 44 and 40 cm (males and females, respectively) in achondroplasia adolescents which is 3.5 cm shorter than non-achondroplasia children at age 1 week and, 38 cm shorter at adolescence. Median sitting height increased from 34 cm at birth to 86 and 81 in adolescents' boys and girls respectively, only 5 cm shorter than non-achondroplasia children. Sitting height/leg length decreased from 2.61 at birth to approximately 1.90 at adolescent. Median head circumference/height ratio decreased from 0.79 at birth to 0.46 at 18 years in both sexes. Growth of lower limbs is affected early in life and becomes more noticeable throughout childhood. The disharmonic growth between the less affected trunk and the severely affected limbs determine body disproportion in achondroplasia. © 2018 Wiley Periodicals, Inc.

  20. Microdose acquisition in adolescent leg length discrepancy using a low-dose biplane imaging system.

    PubMed

    Jensen, Janni; Mussmann, Bo R; Hjarbæk, John; Al-Aubaidi, Zaid; Pedersen, Niels W; Gerke, Oke; Torfing, Trine

    2017-09-01

    Background Children with leg length discrepancy often undergo repeat imaging. Therefore, every effort to reduce radiation dose is important. Using low dose preview images and noise reduction software rather than diagnostic images for length measurements might contribute to reducing dose. Purpose To compare leg length measurements performed on diagnostic images and low dose preview images both acquired using a low-dose bi-planar imaging system. Material and Methods Preview and diagnostic images from 22 patients were retrospectively collected (14 girls, 8 boys; mean age, 12.8 years; age range, 10-15 years). All images were anonymized and measured independently by two musculoskeletal radiologists. Three sets of measurements were performed on all images; the mechanical axis lines of the femur and the tibia as well as the anatomical line of the entire extremity. Statistical significance was tested with a paired t-test. Results No statistically significant difference was found between measurements performed on the preview and on the diagnostic image. The mean tibial length difference between the observers was -0.06 cm (95% confidence interval [CI], -0.12 to 0.01) and -0.08 cm (95% CI, -0.21 to 0.05), respectively; 0.10 cm (95% CI, 0.02-0.17) and 0.06 cm (95% CI, -0.02 to 0.14) for the femoral measurements and 0.12 cm (95% CI, -0.05 to 0.26) and 0.08 cm (95% CI, -0.02 to 0.19) for total leg length discrepancy. ICCs were >0.99 indicating excellent inter- and intra-rater reliability. Conclusion The data strongly imply that leg length measurements performed on preview images from a low-dose bi-planar imaging system are comparable to measurements performed on diagnostic images.

  1. [Reproductive biology of Lutjanus guttatus (Perciformes: Lutjanidae) in Utria National Park, Colombian Pacific].

    PubMed

    Correa-Herrera, Tatiana; Jiménez-Segura, Luz Fernanda

    2013-06-01

    Protected areas are important for natural population conservation since they work as refuge, feeding and breeding areas, where specimens should be exempt from human pressure. The generation of better criteria for management decisions and conservation of fishery resources, is based on the reproductive aspects of species that support fishing activities, since this information is related to the abundance, size and frequency of capture. With this aim, the reproductive biology of the spotted snapper Lutjanus guttatus was studied from April 2008 and February 2009 at the Utría National Park, Colombian Pacific. For this, we analyzed the volume of catch, size structure, sex ratio, fecundity, maturity size, breeding areas and seasons (n = 278), of daily landings of 21 units of artisanal fisheries in ten fishing grounds in the Park. Form all landings, we evaluated a total of 4319 individuals belonging to 84 species. Based on the number of individuals, Lutjanus guttatus ranked third in catches representing 6.4% (278 individuals), and 16th with 1.8% (95.79kg), based on catch biomass. The average weight was 0.34 kg +/- 0.25 kg, while 29 cm +/- 6.4 cm for total length. The total length-weight relationship had the best fit (Kruskal-Wallis, p < 0.05, n = 272) with the equation P(T) = 0.00000885* LT3.09. The occurrence of mature fish and high condition factors suggested a spawning season in June, September and October in sandy and rocky shores. This species showed an asynchronical gonadal development, with a mean sexual maturity size estimated in 23.5cm total length, and an absolute fecundity of 156 253.11 oocytes (mode of 4 microm diameter). We concluded that L. guttatus medium sizes observed indicated a fishing pressure on small size specimens (the minimum size being 18cm); thus, we recommend the implementation of minimum catch sizes based on the criterion of size at maturity LT100 (25.5 cm) and to apply seasonal fishing closures during the highest reproductive activity (June-October). However, it is necessary to obtain additional biological information with multi-year monitoring to improve fisheries management criteria in the area.

  2. Approximate sample sizes required to estimate length distributions

    USGS Publications Warehouse

    Miranda, L.E.

    2007-01-01

    The sample sizes required to estimate fish length were determined by bootstrapping from reference length distributions. Depending on population characteristics and species-specific maximum lengths, 1-cm length-frequency histograms required 375-1,200 fish to estimate within 10% with 80% confidence, 2.5-cm histograms required 150-425 fish, proportional stock density required 75-140 fish, and mean length required 75-160 fish. In general, smaller species, smaller populations, populations with higher mortality, and simpler length statistics required fewer samples. Indices that require low sample sizes may be suitable for monitoring population status, and when large changes in length are evident, additional sampling effort may be allocated to more precisely define length status with more informative estimators. ?? Copyright by the American Fisheries Society 2007.

  3. Stress studies in EFG

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Electrical characterization of defects induced in FZ and CZ silicon stress in four-point bending above 1200 C was started. Techniques to study electrical activity that will permit correlation of defect activity with diffusion length and with room and low temperature EBIC are being developed. Preliminary characterization of defects in ribbon grown at very low speeds of less than 1 cm/min shows that the dislocation density is very low over significant regions of cross section, while regions of high dislocation density (approx. 5 x 10(6)/cm(2)) occur in bands in a number of places. Addition measurements of stress distributions in EFG material were obtained at the University of Illinois using shadow-Moire interferometry.

  4. Perineal body stretch during labor does not predict perineal laceration, postpartum incontinence, or postpartum sexual function: a cohort study.

    PubMed

    Meriwether, Kate V; Rogers, Rebecca G; Dunivan, Gena C; Alldredge, Jill K; Qualls, Clifford; Migliaccio, Laura; Leeman, Lawrence

    2016-08-01

    The perineum stretches naturally during obstetrical labor, but it is unknown whether this stretch has a negative impact on pelvic floor outcomes after a vaginal birth (VB). We aimed to evaluate whether perineal stretch was associated with postpartum pelvic floor dysfunction, and we hypothesized that greater perineal stretch would correlate with worsened outcomes. This was a prospective cohort study of primiparous women who had a VB. Perineal body (PB) length was measured antepartum, during labor, and 6 months postpartum. We determined the maximum PB (PBmax) measurements during the second stage of labor and PB change (ΔPB) between time points. Women completed functional questionnaires and had a Pelvic Organ Prolapse Quantification (POP-Q) system exam 6 months postpartum. We analyzed the relationship of PB measurements to perineal lacerations and postpartum outcomes, including urinary, anal, and fecal incontinence, sexual activity and function, and POP-Q measurements. Four hundred and forty-eight women with VB and a mean age of 24 ± 5.0 years with rare (5 %) third- or fourth-degree lacerations were assessed. During the second stage of labor, 270/448 (60 %) had perineal measurements. Mean antepartum PB length was 3.7 ± 0.8 cm, with a maximum mean PB length (PBmax) during the second stage of 6.1 ± 1.5 cm, an increase of 65 %. The change in PB length (ΔPB) from antepartum to 6 months postpartum was a net decrease (-0.39 ± 1.02 cm). PB change and PBmax were not associated with perineal lacerations or outcomes postpartum (all p > 0.05). PB stretch during labor is unrelated to perineal laceration, postpartum incontinence, sexual activity, or sexual function.

  5. Reproductive biology of the two deep-sea chimaerids, longnose spookfish (Harriotta raleighana) and Pacific spookfish (Rhinochimaera pacifica)

    NASA Astrophysics Data System (ADS)

    Finucci, B.; Dunn, M. R.; Jones, E. G.; Anderson, J.

    2017-02-01

    The family Rhinochimaeridae, the long-nose chimaerids, consists of eight species across three genera, two of which occur in New Zealand waters. Very little is known about the biology of the rhinochimaerids. Longnose spookfish, (Harriotta raleighana, Goode and Bean, 1895), and Pacific spookfish, (Rhinochimaera pacifica,Mitsukuri, 1895), were collected from research trawl surveys and by commercial fishing vessels around New Zealand at depths between 400 and 1300 m. A total of 300 H. raleighana were caught which varied in length from 18.7 to 90.4 cm chimaera length (CL), and 168 R. pacifica at lengths of 20.9-139.9 cm CL. External assessment of male claspers and female gonad mass and oviducal gland width were the best indicators for maturity. Both species matured at a large proportion of their maximum length. Length at maturity was estimated at 62.8 cm CL and 75.8 cm CL for male and female H. raleighana respectively, and 105.3 cm CL and 125.0 cm CL for male and female R. pacifica. Fecundity was low and measured up to 27 eggs for H. raleighana, and 31 eggs for R. pacifica. Sperm storage was confirmed in females of both species. Sexual dimorphism in snout length was found in H. raleighana, where male relative snout size increased at sexual maturity, suggesting the snout is a secondary sexual characteristic. This study contributes to a better understanding of the life histories of H. raleighana and R. pacifica and their vulnerability to exploitation as fisheries bycatch.

  6. In situ biasing and off-axis electron holography of a ZnO nanowire

    NASA Astrophysics Data System (ADS)

    den Hertog, Martien; Donatini, Fabrice; McLeod, Robert; Monroy, Eva; Sartel, Corinne; Sallet, Vincent; Pernot, Julien

    2018-01-01

    Quantitative characterization of electrically active dopants and surface charges in nano-objects is challenging, since most characterization techniques using electrons [1-3], ions [4] or field ionization effects [5-7] study the chemical presence of dopants, which are not necessarily electrically active. We perform cathodoluminescence and voltage contrast experiments on a contacted and biased ZnO nanowire with a Schottky contact and measure the depletion length as a function of reverse bias. We compare these results with state-of-the-art off-axis electron holography in combination with electrical in situ biasing on the same nanowire. The extension of the depletion length under bias observed in scanning electron microscopy based techniques is unusual as it follows a linear rather than square root dependence, and is therefore difficult to model by bulk equations or finite element simulations. In contrast, the analysis of the axial depletion length observed by holography may be compared with three-dimensional simulations, which allows estimating an n-doping level of 1 × 1018 cm-3 and negative sidewall surface charge of 2.5 × 1012 cm-2 of the nanowire, resulting in a radial surface depletion to a depth of 36 nm. We found excellent agreement between the simulated diameter of the undepleted core and the active thickness observed in the experimental data. By combining TEM holography experiments and finite element simulation of the NW electrostatics, the bulk-like character of the nanowire core is revealed.

  7. Histogenesis and disappearance of the teeth of the Mekong giant catfish, Pangasianodon gigas (Teleostei).

    PubMed

    Kakizawa, Yoshiko; Meenakarn, Wanpen

    2003-12-01

    Juveniles of the Mekong giant catfish, Pangasianodon gigas (Teleostei), have 3 sorts of tooth-upper and lower jaw teeth, palatal teeth, and pharyngeal teeth--but adults are toothless. To investigate the histogenesis and disappearance of the teeth, we made serial sections of the mouth and teeth of juvenile fish at 10 developmental stages (from ca. 8.5 to ca. 30 cm in total length) and examined them under scanning electron microscope and light microscope. Observations of teeth and surrounding tissues in the serial sections revealed the process of tooth resorption by active odontoclast-like cells. Numbers of jaw and palatal teeth decreased with age. When the fish reached ca. 14 cm in total length, the numbers of functional upper jaw teeth and successional tooth germs decreased rapidly, and the developmental rate of successional tooth germs slowed. When the fish reached ca. 24 cm, no teeth existed in the upper jaw. It is clear that tooth disappearance results from the shedding of functional teeth and the lack of replacement tooth germs.

  8. Plant-based torsional actuator with memory

    Treesearch

    Nayomi Plaza; Samuel L. Zelinka; Don S. Stone; Joseph E. Jakes

    2013-01-01

    A bundle of a few loblolly pine (Pinus taeda) cells are moisture-activated torsional actuators that twist multiple revolutions per cm length in direct proportion to moisture content. The bundles generate 10 N m kg􀀀1 specific torque during both twisting and untwisting, which is higher than an electric motor. Additionally, the bundles exhibit a moisture-...

  9. Experimental investigation of cooling perimeter and disturbance length effect on stability of Nb3Sn cable-in-conduit conductors

    NASA Astrophysics Data System (ADS)

    Armstrong, J. R.

    1992-02-01

    The stability of three coils, with similar parameters besides having differing strand diameters, was investigated experimentally using inductive heaters to input disturbances. One of the coils stability was also tested by doubling the inductive heated disturbance length to 10 cm. By computationally deriving approximate inductive heater input energy at 12 T, stability curves show fair agreement with zero-dimensional and one-dimensional computer predictions. Quench velocity and limiting currents also show good agreement with earlier work. Also, the stability measured on one of the coils below its limiting current by disturbing a 10 cm length of conductor was much less than the same samples stability using a 5 cm disturbance length.

  10. Cracking of Clay Due to Contact with Waste Chlorinated Solvents

    NASA Astrophysics Data System (ADS)

    Otero, M.; Ayral, D.; Shipan, J.; Goltz, M. N.; Huang, J.; Demond, A. H.

    2012-12-01

    Clays are known to crack upon desiccation. Desiccation cracks of up to 3 cm wide have been reported in natural soils. This raises the question if a similar behavior is seen when a dense non-aqueous phase liquids (DNAPL) waste is in contact with clay. The contact with organic liquids causes the clay structure to shrink, leading to the formation of cracks. Moreover, DNAPL waste not only contains the organic liquid solvent but also includes surface-active solutes or surfactants. Such solutes can enhance the interaction of the organic solvents with the clay. This research will assess whether or not contact with chlorinated organic waste causes cracking. In order to evaluate the possibility of cracking in the clay, microcosms have been constructed that mimic aquifer systems, consisting of a saturated layer of sand, a saturated layer of bentonite clay and a 2.5 cm layer of either pure chlorinated solvents or DNAPL waste. The onset of cracking for the microcosm with tetrachloroethylene (PCE) waste as the DNAPL layer occurred after ten days of contact. Similarly, at eight days, cracks were observed in a microcosm containing trichloroethylene (TCE) waste . Forty-four days later, the length and number of cracks have grown considerably; with a total crack length of 50 cm on a surface of 80 cm2 in the microcosm containing PCE waste. On the other hand it took approximately 161 days for the clay layer in the microcosm containing pure PCE to crack. To quantity the degree of cracking, crack maps were developed using the image software, Image J. Characteristics like crack length, crack aperture, and the percentage of total length for a range of apertures were calculated using this software. For example, for the PCE waste microcosm, it was calculated that 3.7% of the crack length had an aperture of 100-300 microns, 15.1% of the crack length had an aperture of 300-500 microns, 29.7% of the crack length had an aperture of 500-700 microns, 40.1% of the crack length had an aperture of 700-900 microns, 6.3% had an aperture of 900-1,100 microns and 5.1% had an aperture of over 1,100 microns. These data suggest that aquitards in the field might crack when in contact with the DNAPL waste. Moreover, it is apparent that the waste contains solutes that accelerate the cracking of the clay layer. Thus, models examining the impact of storage in low permeability layers need to consider the possible impact of cracking.

  11. Specific force of the vastus lateralis in adults with achondroplasia.

    PubMed

    Sims, David T; Onambélé-Pearson, Gladys L; Burden, Adrian; Payton, Carl; Morse, Christopher I

    2018-03-01

    Achondroplasia is a clinical condition defined by shorter stature and disproportionate limb length. Force production in able-bodied individuals (controls) is proportional to muscle size, but given the disproportionate nature of achondroplasia, normalizing to anatomical cross-sectional area (ACSA) is inappropriate. The aim of this study was to assess specific force of the vastus lateralis (VL) in 10 adults with achondroplasia (22 ± 3 yr) and 18 sex-matched controls (22 ± 2 yr). Isometric torque (iMVCτ) of the dominant knee extensors (KE) and in vivo measures of VL muscle architecture, volume, activation, and patella tendon moment arm were used to calculate VL physiological CSA (PCSA), fascicle force, and specific force in both groups. Achondroplasic muscle volume was 53% smaller than controls (284 ± 36 vs. 604 ± 102 cm 3 , P < 0.001). KE iMVCτ was 63% lower in achondroplasia compared with controls (95 ± 24 vs. 256 ± 47 N⋅m, P < 0.001). Activation and moment arm length were similar between groups ( P > 0.05), but coactivation of bicep femoris of achondroplasic subjects was 70% more than controls (43 ± 20 vs. 13 ± 5%, P < 0.001). Achondroplasic subjects had 58% less PCSA (43 ± 10 vs. 74.7 ± 14 cm 2 , P < 0.001), 29% lower fascicle force (702 ± 235 vs. 1704 ± 303 N, P < 0.001), and 29% lower specific force than control subjects (17 ± 6 vs. 24 ± 6 N⋅cm -2 , P = 0.012). The smaller VL specific force in achondroplasia may be attributed to infiltration of fat and connective tissue, rather than to any difference in myofilament function. NEW & NOTEWORTHY The novel observation of this study was the measurement of normalized force production in a group of individuals with disproportionate limb length-to-torso ratios.

  12. Long-term outcomes in males with disorders of sex development.

    PubMed

    van der Zwan, Yvonne G; Callens, Nina; van Kuppenveld, Jet; Kwak, Karen; Drop, Stenvert L S; Kortmann, Barbara; Dessens, Arianne B; Wolffenbuttel, Katja P

    2013-09-01

    Indications that the prenatal action of testosterone in the brain is an important determinant of gender development and improved reconstructive techniques have caused a shift in male gender assignments in patients with 46XY disorders of sex development. We report long-term outcome data on psychosexual development and sexual function of these individuals in a cross-sectional study. Physical status of 14 men with a mean age of 25 years with disorders of sex development was assessed by structured interview and physical examination. Psychosexual outcome was evaluated by questionnaires and compared to a control group of 46 healthy, age matched men. A total of 13 men underwent 1 to 6 (mean 2) genital surgeries. Mean age at first surgery was 2.7 years. Mean penile length was 6.6 cm. All men reported erections and were able to experience orgasms. Ejaculatory dysfunction was reported by 7 men. Mean penile length was 7.9 cm in patients who were able to achieve penetrative intercourse and 4.9 cm in those who were not. Meatus was glanular in 5 patients, coronal in 7 and at the distal shaft in 1. Compared to controls, men with disorders of sex development were less satisfied with the appearance of the penis and scrotum but not with total body image. These patients reported decreased sexual desire and activities. Outcome in this group of men with disorders of sex development was poor regarding penile length, ejaculation, satisfaction with external genitalia and frequency of sexual activity. Other aspects, such as overall body image and psychosexual functioning, showed no difference from controls. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. 16 CFR 500.12 - Measurement of commodities by length and width, how expressed.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... square foot (929 cm2) be expressed in terms of length and width in linear measure. The customary inch... of 1 square foot (929 cm2) or more, but less than 4 square feet (37.1 dm2), be expressed in terms of... in square inches with length and width expressed in the largest whole unit (yard or foot) with any...

  14. 16 CFR 500.12 - Measurement of commodities by length and width, how expressed.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... square foot (929 cm2) be expressed in terms of length and width in linear measure. The customary inch... of 1 square foot (929 cm2) or more, but less than 4 square feet (37.1 dm2), be expressed in terms of... in square inches with length and width expressed in the largest whole unit (yard or foot) with any...

  15. 16 CFR 500.12 - Measurement of commodities by length and width, how expressed.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... square foot (929 cm2) be expressed in terms of length and width in linear measure. The customary inch... of 1 square foot (929 cm2) or more, but less than 4 square feet (37.1 dm2), be expressed in terms of... in square inches with length and width expressed in the largest whole unit (yard or foot) with any...

  16. 16 CFR 500.12 - Measurement of commodities by length and width, how expressed.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... square foot (929 cm2) be expressed in terms of length and width in linear measure. The customary inch... of 1 square foot (929 cm2) or more, but less than 4 square feet (37.1 dm2), be expressed in terms of... in square inches with length and width expressed in the largest whole unit (yard or foot) with any...

  17. Environmental tobacco smoke exposure and perinatal outcomes: a systematic review and meta-analyses.

    PubMed

    Salmasi, Giselle; Grady, Rosheen; Jones, Jennifer; McDonald, Sarah D

    2010-01-01

    While active maternal tobacco smoking has well established adverse perinatal outcomes, the effects of passive maternal smoking, also called environmental tobacco exposure (ETS), are less well studied and less consistent. To determine to the effect of ETS on perinatal outcomes. Medline, EMBASE and reference lists were searched. Studies comparing ETS-exposed pregnant women with those unexposed which adequately addressed active maternal smoking. Two reviewers independently assessed titles, abstracts, full studies, extracted data and assessed quality. Dichotomous data were pooled using odds ratios (OR) and continuous data with weighted mean differences (WMD) using a random effects model. Seventy-six articles were included with a total of 48,439 ETS-exposed women and 90,918 unexposed women. ETS-exposed infants weighed less [WMD -60 g, 95% confidence interval (CI) -80 to -39 g], with a trend towards increased low birthweight (LBW, < 2,500 g; RR 1.16; 95% CI 0.99-1.36), although the duration of gestation and preterm delivery were similar (WMD 0.02 weeks, 95% CI -0.09 to 0.12 weeks and RR 1.07; 95% CI 0.93-1.22). ETS-exposed infants had longer infant lengths (1.75 cm; 95% CI 1.37-2.12 cm), increased risks of congenital anomalies (OR 1.17; 95% CI 1.03-1.34) and a trend towards smaller head circumferences (-0.11 cm; 95% CI -0.22 to 0.01 cm). ETS-exposed women have increased risks of infants with lower birthweight, congenital anomalies, longer lengths, and trends towards smaller head circumferences and LBW.

  18. A statistical model that predicts the length from the left subclavian artery to the celiac axis; towards accurate intra aortic balloon sizing.

    PubMed

    Parissis, Haralabos; Soo, Alan; Leotsinidis, Michalis; Dougenis, Dimitrios

    2011-08-09

    Ideally the length of the Intraaortic balloon membrane (22-27.5 cm) should match to the distance from the left subclavian artery (LSA) to the celiac axis (CA), (LSA - CA). By being able to estimate this distance, better guidance regarding IABP sizing could be recommended. Internal aortic lengths and demographic values were collected from a series of 40 cadavers during autopsy. External somatometric measurements were also obtained.There were 23 males and 17 females. The mean age was 73.1+/-13.11 years, weight 56.75+/-12.51 kg and the height 166+/-9.81 cm. Multiple regression analysis revealed the following predictor variables (R2 > 0.70) for estimating the length from LSA to CA: height (standardized coefficient (SRC) = 0.37, p = 0.004), age (SRC = 0.35, p < 0.001), sex (SRC = 0.21, p = 0.088) and the distance from the jugular notch to trans-pyloric plane (SRC = 0.61, p < 0.001). If LSA-CA < 21.9 cm use 34 cc IABP & if LSA-CA > 26.3 cm use 50 cc IABP. However if LSA-CA = 21.9- 26.3 cm use 40 cc, but be aware that it could be "aortic length-balloon membrane length" mismatching. Routinely, IABP size selection is being dictated by the patient's height. Inevitably, this leads to pitfalls. We reported a mathematical model of accurate intraaortic balloon sizing, which is easy to be applied and has a high predictive value.

  19. Electromyographic evaluation of masseter muscle activity in horses fed (i) different types of roughage and (ii) maize after different hay allocations.

    PubMed

    Vervuert, I; Brüssow, N; Bochnia, M; Cuddeford, D; Coenen, M

    2013-06-01

    The aims of this study were to monitor electromyographic (EMG) activity of masseter muscle in healthy horses fed (i) different types of roughage and (ii) maize after different hay allocations. Four horses were offered the following three diets ad libitum: hay, haylage or straw/alfalfa chaff (SAC). In a second trial, four horses were fed cracked maize (CM) and hay in three different orders: (i) CM after a 12-h overnight fast; (ii) CM immediately after restricted hay intake (0.6 kg hay/100 kg BW); or 3) CM after hay intake ad libitum. The activity of the masseter muscle was determined by EMG (IED(®) ), and the following were measured: amplitude (muscle action potential = MAP, maximum voltage) and duration of MAP (s). The intake of hay or haylage was associated with intense masseter muscle activity (MAP: hay, 10 ± 1.7 V; haylage, 11 ± 3.3 V; and duration of MAP: hay, 0.31 ± 0.04 s; haylage, 0.30 ± 0.04 s). Similar intense chewing was measured for SAC (MAP 13 ± 3.8 V), although duration of the chewing cycle was relatively short (0.22 ± 0.03 s, diet p < 0.05), which is possibly related to the shorter fibre length. CM was consumed rapidly, with less intense masseter muscle activity (MAP 6.0 ± 1.5 V). Hay intake before CM did not affect chewing force of CM, but duration of chewing cycle was significantly prolonged by feeding hay ad libitum before CM was fed. The consumption of hay, haylage or SAC was associated with intensive masseter muscle activity that was likely to stimulate salivary flow rate. In contrast to roughage, concentrates like CM are consumed rapidly with less intensive masseter muscle activity. This situation is associated with a low salivary flow that may have an adverse effect on gastric function. © 2012 Blackwell Verlag GmbH.

  20. Phototherapy of Barrett's esophagus

    NASA Astrophysics Data System (ADS)

    Wang, Kenneth K.; Gutta, Kumar; Laukka, Mark A.

    1994-07-01

    Barrett's esophagus is a common premalignant disease. The aim of this study is to determine if low dose photodynamic therapy is capable of ablating Barrett's epithelium allowing regrowth of normal squamous mucosa. Methods: Patients with specialized Barrett's esophagus of at least 3 cm length were given 1.5-1.75 mg/kg of hematoporphyrin derivative intravenously. After 48 hours, esophagoscopy and videotaping of the Barrett's was performed. A 1.0-1.5 cm cylindrical diffusing fiber delivered light of 630 nm in a dose of 150-200 J/cm using a tunable dye laser at a power of 400 mW/cm. Following entry, patients were placed on omeprazole 20 mg/day for six months. Results: Twelve patients (8 men) mean age of 62 +/- 4 have had repeat endoscopy performed at 25 +/- 2 weeks following entry. The Barrett's segment length decreased from 8+/- 1 to 5+/- 1 cm after PDT (p < 0.01) with a corresponding change in the appearance and location of the squamocolumnar junction. Six (50%) of the patients had a 4 cm or more decrease in the length of their Barrett's esophagus with normal squamous mucosa on biopsy. Adverse events included transient odynophagia, minor sunburn, and transient chest pain. Conclusions: Photodynamic therapy of Barrett's esophagus can cause a regression in length of the Barrett's segment with replacement by normal squamous epithelium.

  1. Alternative splicing: a novel mechanism of regulation identified in the chorismate mutase gene of the potato cyst nematode Globodera rostochiensis.

    PubMed

    Lu, Shun-Wen; Tian, Duanhua; Borchardt-Wier, Harmony B; Wang, Xiaohong

    2008-11-01

    Chorismate mutase (CM) secreted from the stylet of plant-parasitic nematodes plays an important role in plant parasitism. We isolated and characterized a new nematode CM gene (Gr-cm-1) from the potato cyst nematode, Globodera rostochiensis. The Gr-cm-1 gene was found to exist in the nematode genome as a single-copy gene that has two different alleles, Gr-cm-1A and Gr-cm-1B, both of which could give rise to two different mRNA transcripts of Gr-cm-1 and Gr-cm-1-IRII. In situ mRNA hybridization showed that the Gr-cm-1 gene was exclusively expressed within the subventral oesophageal gland cells of the nematode. Gr-cm-1 was demonstrated to encode a functional CM (GR-CM-1) potentially having a dimeric structure as the secreted bacterial *AroQ CMs. Gr-cm-1-IRII, generated by retention of intron 2 of the Gr-cm-1 pre-mRNA through alternative splicing (AS), would encode a truncated protein (GR-CM-1t) lacking the CM domain with no CM activity. The quantitative real-time reverse transcription-PCR assay revealed that splicing of the Gr-cm-1 gene was developmentally regulated; Gr-cm-1 was up-regulated whereas Gr-cm-1-IRII was down-regulated in early nematode parasitic stages compared to the preparasitic juvenile stage. Low-temperature SDS-PAGE analysis revealed that GR-CM-1 could form homodimers when expressed in Escherichia coli and the dimerization domain was retained in the truncated GR-CM-1t protein. The specific interaction between the two proteins was demonstrated in yeast. Our data suggested that the novel splice variant might function as a dominant negative isoform through heterodimerization with the full-length GR-CM-1 protein and that AS may represent an important mechanism for regulating CM activity during nematode parasitism.

  2. Burst Speed of Wild Fishes under High-Velocity Flow Conditions Using Stamina Tunnel with Natural Guidance System in River

    NASA Astrophysics Data System (ADS)

    Izumi, Mattashi; Yamamoto, Yasuyuki; Yataya, Kenichi; Kamiyama, Kohhei

    Swimming experiments were conducted on wild fishes in a natural guidance system stamina tunnel (cylindrical pipe) installed in a fishway of a local river under high-velocity flow conditions (tunnel flow velocity : 211 to 279 cm·s-1). In this study, the swimming characteristics of fishes were observed. The results show that (1) the swimming speeds of Tribolodon hakonensis (Japanese dace), Phoxinus lagowshi steindachneri (Japanese fat-minnow), Plecoglossus altivelis (Ayu), and Zacco platypus (Pale chub) were in proportion to their body length under identical water flow velocity conditions; (2) the maximum burst speed of Japanese dace and Japanese fat-minnow (measuring 4 to 6 cm in length) was 262 to 319 cm·s-1 under high flow velocity conditions (225 to 230 cm·s-1), while the maximum burst speed of Ayu and Pale chub (measuring 5 cm to 12 cm in length) was 308 to 355 cm·s-1 under high flow velocity conditions (264 to 273 cm·s-1) ; (3) the 50cm-maximum swimming speed of swimming fishes was 1.07 times faster than the pipe-swimming speed; (4) the faster the flow velocity, the shorter the swimming distance became.

  3. A fully resolved fluid-structure-muscle-activation model for esophageal transport

    NASA Astrophysics Data System (ADS)

    Kou, Wenjun; Bhalla, Amneet P. S.; Griffith, Boyce E.; Johnson, Mark; Patankar, Neelesh A.

    2013-11-01

    Esophageal transport is a mechanical and physiological process that transfers the ingested food bolus from the pharynx to the stomach through a multi-layered esophageal tube. The process involves interactions between the bolus, esophageal wall composed of mucosal, circular muscle (CM) and longitudinal muscle (LM) layers, and neurally coordinated muscle activation including CM contraction and LM shortening. In this work, we present a 3D fully-resolved model of esophageal transport based on the immersed boundary method. The model describes the bolus as a Newtonian fluid, the esophageal wall as a multi-layered elastic tube represented by springs and beams, and the muscle activation as a traveling wave of sequential actuation/relaxation of muscle fibers, represented by springs with dynamic rest lengths. Results on intraluminal pressure profile and bolus shape will be shown, which are qualitatively consistent with experimental observations. Effects of activating CM contraction only, LM shortening only or both, for the bolus transport, are studied. A comparison among them can help to identify the role of each type of muscle activation. The support of grant R01 DK56033 and R01 DK079902 from NIH is gratefully acknowledged.

  4. Colorectal anatomy in adults at computed tomography colonography: normal distribution and the effect of age, sex, and body mass index.

    PubMed

    Khashab, M A; Pickhardt, P J; Kim, D H; Rex, D K

    2009-08-01

    Computed tomography colonography (CTC) is an accurate tool for assessing the large intestinal anatomy. Our aims were to determine the normal distribution of in vivo colorectal anatomy and to investigate the effect of age, sex, and body mass index (BMI) on colorectal length. Asymptomatic adults who underwent primary CTC examination at a single institution over an 8-month period were evaluated. The interactive three-dimensional map was used to determine total and segmental lengths and number of acute-angle flexures. The two-dimensional multiplanar display was used to measure luminal diameters. The effects of age, sex, and BMI on colorectal lengths were examined. The study cohort consisted of 505 consecutive adults (266 women, mean age 56.6 years). Mean total colorectal length was 189.5 +/- 26.3 cm and mean number of acute-angle flexures was 10.9 +/- 2.4. Total length for older adults (> 60 years) did not significantly differ from those who were younger than 60 years ( P = 0.22), although the transverse colon was significantly longer in older adults ( P = 0.04). Women had significantly longer colons than men (193.3 cm vs. 185.4 cm, P = 0.002), whereas overweight adults (BMI > 25) had significantly shorter colons compared with those with BMI

  5. Effect of penile-extender device in increasing penile size in men with shortened penis: preliminary results.

    PubMed

    Nikoobakht, Mohammadreza; Shahnazari, Alireza; Rezaeidanesh, Maedeh; Mehrsai, Abdolrasoul; Pourmand, Gholamreza

    2011-11-01

    It has been suggested that the application of penile-extender devices increases penile length and circumference. However, there are a few scientific studies in this field. The aim of this study was to assess the efficacy of a penile-extender (Golden Erect(®) , Ronas Tajhiz Teb, Tehran, Iran) in increasing penile size. This prospective study was performed on subjects complaining about "short penis" who were presented to our clinic between September 15, 2008 and December 15, 2008. After measuring the penile length in flaccid and stretched forms and penile circumference, patients were instructed to wear Golden Erect(®) , 4-6 hours per day during the first 2 weeks and then 9 hours per day until the end of the third month. The subjects were also trained how to increase the force of the device during determined intervals. The patients were visited at the end of the first and third months, and penile length and circumference were measured and compared with baseline. The primary end point of the study was changes in flaccid and stretched penile lengths compared with the baseline size during the 3 months follow-up. Twenty-three cases with a mean age of 26.5 ± 8.1 years entered the study. The mean flaccid penile length increased from 8.8 ± 1.2 cm to 10.1 ± 1.2 cm and 10.5 ± 1.2 cm, respectively, in the first and third months of follow-up, which was statistically significant (P < 0.05). Mean stretched penile length also significantly increased from 11.5 ± 1.0 cm to, respectively, 12.4 ± 1.3 cm and 13.2 ± 1.4 cm during the first and second follow-up (P < 0.05). No significant difference was found regarding proximal penile girth. However, it was not the same regarding the circumference of the glans penis (9.3 ± 0.86 cm vs. 8.8 ± 0.66 cm, P < 0.05). Our findings supported the efficacy of the device in increasing penile length. Our result also suggested the possibility of glans penis girth enhancement using penile extender. Performing more studies is recommended. © 2010 International Society for Sexual Medicine.

  6. Thermal Cyclic Resistance Polyester Resin Composites Reinforce Fiber Nut Shell

    NASA Astrophysics Data System (ADS)

    Fahmi, Hendriwan

    2017-12-01

    The purpose of study is to determine the effect of fiber length and thermal cyclic of the bending strength of polyester resin composite reinforced by fibers nut shell. The materials used in this study is a nut shell fibers with fiber length of 1 cm, 2 cm and 3 cm and polyester resin with composition 70-30%wt. Fiber nut shell treated soaking in NaOH 30% for 30 minutes, then rinse with clean water so that the fiber free of alkali and then dried. Furthermore, the composite is heated in an oven to a temperature of 100°C for 1 hour and then cooled in the open with a variety of thermal cyclic 30, 40, and 50 times. Bending properties of composites known through the testing process using a three-point bending test equipment universal testing machine. The test results show that the bending strength bending highest in fiber length of 3 cm with 30 treatment cycles of thermal to the value of 53.325 MPa, while the lowest occurred in bending strength fiber length of 1 cm with no cycles of thermal treatment to the value of 30.675 MPa.

  7. Am I normal? A systematic review and construction of nomograms for flaccid and erect penis length and circumference in up to 15,521 men.

    PubMed

    Veale, David; Miles, Sarah; Bramley, Sally; Muir, Gordon; Hodsoll, John

    2015-06-01

    To systematically review and create nomograms of flaccid and erect penile size measurements. Study key eligibility criteria: measurement of penis size by a health professional using a standard procedure; a minimum of 50 participants per sample. samples with a congenital or acquired penile abnormality, previous surgery, complaint of small penis size or erectile dysfunction. Synthesis methods: calculation of a weighted mean and pooled standard deviation (SD) and simulation of 20,000 observations from the normal distribution to generate nomograms of penis size. Nomograms for flaccid pendulous [n = 10,704, mean (SD) 9.16 (1.57) cm] and stretched length [n = 14,160, mean (SD) 13.24 (1.89) cm], erect length [n = 692, mean (SD) 13.12 (1.66) cm], flaccid circumference [n = 9407, mean (SD) 9.31 (0.90) cm], and erect circumference [n = 381, mean (SD) 11.66 (1.10) cm] were constructed. Consistent and strongest significant correlation was between flaccid stretched or erect length and height, which ranged from r = 0.2 to 0.6. relatively few erect measurements were conducted in a clinical setting and the greatest variability between studies was seen with flaccid stretched length. Penis size nomograms may be useful in clinical and therapeutic settings to counsel men and for academic research. © 2014 The Authors. BJU International © 2014 BJU International.

  8. SU-E-T-579: Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, H; Gopalakrishnan, M; Lee, P

    2014-06-01

    Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according tomore » the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.« less

  9. A methodology for direct quantification of over-ranging length in helical computed tomography with real-time dosimetry.

    PubMed

    Tien, Christopher J; Winslow, James F; Hintenlang, David E

    2011-01-31

    In helical computed tomography (CT), reconstruction information from volumes adjacent to the clinical volume of interest (VOI) is required for proper reconstruction. Previous studies have relied upon either operator console readings or indirect extrapolation of measurements in order to determine the over-ranging length of a scan. This paper presents a methodology for the direct quantification of over-ranging dose contributions using real-time dosimetry. A Siemens SOMATOM Sensation 16 multislice helical CT scanner is used with a novel real-time "point" fiber-optic dosimeter system with 10 ms temporal resolution to measure over-ranging length, which is also expressed in dose-length-product (DLP). Film was used to benchmark the exact length of over-ranging. Over-ranging length varied from 4.38 cm at pitch of 0.5 to 6.72 cm at a pitch of 1.5, which corresponds to DLP of 131 to 202 mGy-cm. The dose-extrapolation method of Van der Molen et al. yielded results within 3%, while the console reading method of Tzedakis et al. yielded consistently larger over-ranging lengths. From film measurements, it was determined that Tzedakis et al. overestimated over-ranging lengths by one-half of beam collimation width. Over-ranging length measured as a function of reconstruction slice thicknesses produced two linear regions similar to previous publications. Over-ranging is quantified with both absolute length and DLP, which contributes about 60 mGy-cm or about 10% of DLP for a routine abdominal scan. This paper presents a direct physical measurement of over-ranging length within 10% of previous methodologies. Current uncertainties are less than 1%, in comparison with 5% in other methodologies. Clinical implantation can be increased by using only one dosimeter if codependence with console readings is acceptable, with an uncertainty of 1.1% This methodology will be applied to different vendors, models, and postprocessing methods--which have been shown to produce over-ranging lengths differing by 125%.

  10. Chronic endurance exercise affects paracrine action of CD31+ and CD34+ cells on endothelial tube formation

    PubMed Central

    Landers-Ramos, Rian Q.; Sapp, Ryan M.; Jenkins, Nathan T.; Murphy, Anna E.; Cancre, Lucile; Chin, Eva R.; Spangenburg, Espen E.

    2015-01-01

    We aimed to determine if chronic endurance-exercise habits affected redox status and paracrine function of CD34+ and CD34−/CD31+ circulating angiogenic cells (CACs). Subjects were healthy, nonsmoking men and women aged 18–35 yr and categorized by chronic physical activity habits. Blood was drawn from each subject for isolation and culture of CD34+ and CD34−/CD31+ CACs. No differences in redox status were found in any group across either cell type. Conditioned media (CM) was generated from the cultured CACs and used in an in vitro human umbilical vein endothelial cell-based tube assay. CM from CD34+ cells from inactive individuals resulted in tube structures that were 29% shorter in length (P < 0.05) and 45% less complex (P < 0.05) than the endurance-trained group. CD34−/CD31+ CM from inactive subjects resulted in tube structures that were 26% shorter in length (P < 0.05) and 42% less complex (P < 0.05) than endurance-trained individuals. Proteomics analyses identified S100A8 and S100A9 in the CM. S100A9 levels were 103% higher (P < 0.05) and S100A8 was 97% higher in the CD34−/CD31+ CM of inactive subjects compared with their endurance-trained counterparts with no significant differences in either protein in the CM of CD34+ CACs as a function of training status. Recombinant S100A8/A9 treatment at concentrations detected in inactive subjects' CD34−/CD31+ CAC CM also reduced tube formation (P < 0.05). These findings are the first, to our knowledge, to demonstrate a differential paracrine role in CD34+ and CD34−/CD31+ CACs on tube formation as a function of chronic physical activity habits and identifies a differential secretion of S100A9 by CD34−/CD31+ CACs due to habitual exercise. PMID:26055789

  11. Nonequilibrium transport in superconducting filaments

    NASA Technical Reports Server (NTRS)

    Arutyunov, K. YU.; Danilova, N. P.; Nikolaeva, A. A.

    1995-01-01

    The step-like current-voltage characteristics of highly homogeneous single-crystalline tin and indium thin filaments has been measured. The length of the samples L approximately 1 cm was much greater than the nonequilibrium quasiparticle relaxation length Lambda. It was found that the activation of a successive i-th voltage step occurs at current significantly greater than the one derived with the assumption that the phase slip centers are weakly interacting on a scale L much greater than Lambda. The observation of 'subharmonic' fine structure on the voltage-current characteristics of tin filaments confirms the hypothesis of the long-range phase slip centers interaction.

  12. Assessment of the quality of cervical mucus among users of the levonorgestrel-releasing intrauterine system at different times of use.

    PubMed

    Moraes, Leticia G; Marchi, Nadia M; Pitoli, Ana C; Hidalgo, Maria M; Silveira, Carolina; Modesto, Waleska; Bahamondes, Luis

    2016-08-01

    The quality of cervical mucus (CM) among the levonorgestrel-releasing intrauterine system (LNG-IUS) users is controversial. The objectives were to assess CM compared to the levels of oestradiol (E2) and the frequency of cycles with luteal activity among users of the LNG-IUS. In total, 224 LNG-IUS users for between two months and five years were recruited at a Brazilian family planning clinic. For the cross-sectional part of the study, we enrolled 175 LNG-IUS users at 2, 6 12, 24, 36, 48, and 60 months after insertion (25 women in each group), and we performed one evaluation. For the prospective part of the study, we enrolled 49 LNG-IUS users at the same lengths of use after insertion (7 women in each group), and we evaluated these women once a week for five consecutive weeks. . Mean (± SEM) CM scores of all evaluations among women with single and weekly evaluations were between 3.3 ± 0.9 and 8.5 ± 0.3, respectively independently of the length of use of the LNG-IUS. Mean E2 values ranged from 45.5 ± 6.8 to 472.5 ± 34.7 pg/ml and the maximum ovarian follicle diameter on the days of evaluation varied from 14.0 ± 1.3 to 31.2 ± 0.4 mm. The mean CM score of all evaluations, independent of the length of use of the LNG-IUS and normal levels of serum E2, was below 10 was according to the WHO is inadequate for sperm penetration.

  13. Results of the Imager for Mars Pathfinder windsock experiment

    USGS Publications Warehouse

    Sullivan, R.; Greeley, R.; Kraft, M.; Wilson, G.; Golombek, M.; Herkenhoff, K.; Murphy, J.; Smith, P.

    2000-01-01

    The Imager for Mars Pathfinder (IMP) windsock experiment measured wind speeds at three heights within 1.2 m of the Martian surface during Pathfinder landed operations. These wind data allowed direct measurement of near-surface wind profiles on Mars for the first time, including determination of aerodynamic roughness length and wind friction speeds. Winds were light during periods of windsock imaging, but data from the strongest breezes indicate aerodynamic roughness length of 3 cm at the landing site, with wind friction speeds reaching 1 m/s. Maximum wind friction speeds were about half of the threshold-of-motion friction speeds predicted for loose, fine-grained materials on smooth Martian terrain and about one third of the threshold-of-motion friction speeds predicted for the same size particles over terrain with aerodynamic roughness of 3 cm. Consistent with this, and suggesting that low wind speeds prevailed when the windsock array was not imaged and/or no particles were available for aeolian transport, no wind-related changes to the surface during mission operations have been recognized. The aerodynamic roughness length reported here implies that proposed deflation of fine particles around the landing site, or activation of duneforms seen by IMP and Sojourner, would require wind speeds >28 m/s at the Pathfinder top windsock height (or >31 m/s at the equivalent Viking wind sensor height of 1.6 m) and wind speeds >45 m/s above 10 m. These wind speeds would cause rock abrasion if a supply of durable particles were available for saltation. Previous analyses indicate that the Pathfinder landing site probably is rockier and rougher than many other plains units on Mars, so aerodynamic roughness length elsewhere probably is less than the 3-cm value reported for the Pathfinder site. Copyright 2000 by the American Geophysical Union.

  14. Measuring New Born Foot Length to Identify Small Babies in Need of Extra Care: a Cross-Sectional Hospital Based Study

    PubMed Central

    Mukherjee, Satarupa; Roy, Prithwish; Mitra, Souvik; Samanta, Moumita; Chatterjee, Sukanta

    2013-01-01

    Objective The neonatal mortality rate (NMR) continues to remain quite high, one important cause being preterm deliveries. The main obstacle in the pathway towards decreasing NMR is identification of babies in need of extra care. To analyze the utility of newborn foot length as a proxy measure for birth weight and gestational age. Methods A cross-sectional study done in a hospital of eastern India with 351 babies during 4 months. Right foot length of each recorded using a plastic, stiff ruler. Findings 48.1% babies were preterm, 51.8% low birth weight (LBW) and 33.3% very low birth weight (VLBW). Foot length less than 7.75 cm has 92.3% sensitivity and 86.3% specificity for identification of preterm neonates. For identification of LBW babies (<2500 gm) a foot length less than 7.85cm has 100% sensitivity and 95.3% specificity. Foot length less than 6.85 cm has 100% sensitivity and 94.9% specifity for identification of VLBW babies (<1500 gm). Conclusion Foot length may be used in the identification of LBW and preterm babies who are in need of extra care. PMID:24800008

  15. Detection of tightly closed flaws by nondestructive testing (NDT) methods in steel and titanium

    NASA Technical Reports Server (NTRS)

    Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Tedrow, T. L.; Mullen, S. J.

    1976-01-01

    X-radiographic, liquid penetrant, ultrasonic, eddy current and magnetic particle testing techniques were optimized and applied to the evaluation of 4340 steel (180 KSI-UTS) and 6Al-4V titanium (STA) alloy specimens. Sixty steel specimens containing a total of 176 fatigue cracks and 60 titanium specimens containing a total of 135 fatigue cracks were evaluated. The cracks ranged in length from .043 cm (0.017 inch) to 1.02 cm (.400 inch) and in depth from .005 cm (.002 inch) to .239 cm (.094 inch) for steel specimens. Lengths ranged from .048 cm (0.019 inch) to 1.03 cm (.407 inch) and depths from 0.010 cm (.004 inch) to .261 cm (0.103 inch) for titanium specimens. Specimen thicknesses were nominally .152 cm (0.060 inch) and 0.635 cm (0.250 inch) and surface finishes were nominally 125 rms. Specimens were evaluated in the "as machined" surface condition, after etch surface and after proof loading in a randomized inspection sequence.

  16. InAs-based interband-cascade-lasers emitting around 7 μm with threshold current densities below 1 kA/cm{sup 2} at room temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dallner, Matthias; Hau, Florian; Kamp, Martin

    2015-01-26

    Interband cascade lasers (ICLs) grown on InAs substrates with threshold current densities below 1 kA/cm{sup 2} are presented. Two cascade designs with different lengths of the electron injector were investigated. Using a cascade design with 3 InAs quantum wells (QWs) in the electron injector, a device incorporating 22 stages in the active region exhibited a threshold current density of 940 A/cm{sup 2} at a record wavelength of 7 μm for ICLs operating in pulsed mode at room temperature. By investigating the influence of the number of stages on the device performance for a cascade design with 2 QWs in the electron injector, amore » further reduction of the threshold current density to 800 A/cm{sup 2} was achieved for a 30 stage device.« less

  17. The mechanism and realization of a band-agile coaxial relativistic backward-wave oscillator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ge, Xingjun; Zhang, Jun; Zhong, Huihuang

    2014-11-03

    The mechanism and realization of a band-agile coaxial relativistic backward-wave oscillator (RBWO) are presented. The operation frequency tuning can be easily achieved by merely altering the inner-conductor length. The key effects of the inner-conductor length contributing to the mechanical frequency tunability are investigated theoretically and experimentally. There is a specific inner-conductor length where the operation frequency can jump from one mode to another mode, which belongs to a different operation band. In addition, the operation frequency is tunable within each operation band. During simulation, the L-band microwave with a frequency of 1.61 GHz is radiated when the inner-conductor length ismore » 39 cm. Meanwhile, the S-band microwave with a frequency of 2.32 GHz is radiated when the inner-conductor length is 5 cm. The frequency adjustment bandwidths of L-band and S-band are about 8.5% and 2%, respectively. Moreover, the online mechanical tunability process is described in detail. In the initial experiment, the generated microwave frequencies remain approximately 1.59 GHz and 2.35 GHz when the inner-conductor lengths are 39 cm and 5 cm. In brief, this technical route of the band-agile coaxial RBWO is feasible and provides a guide to design other types of band-agile high power microwaves sources.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Q. G.; Chen, N.; Zhang, M.

    Five IDs will be built for the Shanghai Synchrotron Radiation Facility (SSRF). Two identical mini-gap undulators with the period length 25mm and the minimum gap 6mm will use the in-vacuum technology and can operate in tapered mode. Two wigglers with the period lengths 7.9cm and 14cm and the same minimum gap 14mm will produce the peak fields of 1.2T and 1.94T. A variable polarization undulator of the APPLE-II type with 4.2m long and the period length 10cm can provide linearly, circularly and elliptically polarized radiation in a wide spectral range. This paper describes the magnet designs and the mechanical structuremore » designs of these IDs.« less

  19. The effect of keyboard key spacing on typing speed, error, usability, and biomechanics, Part 2: Vertical spacing.

    PubMed

    Pereira, Anna; Hsieh, Chih-Ming; Laroche, Charles; Rempel, David

    2014-06-01

    The objective was to evaluate the effects of vertical key spacing on a conventional computer keyboard on typing speed, percentage error, usability, forearm muscle activity, and wrist posture for both females with small fingers and males with large fingers. Part I evaluated primarily horizontal key spacing and found that for male typists with large fingers, productivity and usability were similar for spacings of 17, 18, and 19 mm but were reduced for spacings of 16 mm. Few other key spacing studies are available, and the international standards that specify the spacing between keys on a keyboard have been mainly guided by design convention. Experienced female typists (n = 26) with small fingers (middle finger length < or = 7.71 cm or finger breadth of < or = 1.93 cm) and male typists (n = 26) with large fingers (middle finger length > or = 8.37 cm or finger breadth of > or = 2.24 cm) typed on five keyboards that differed primarily in vertical key spacing (17 x 18, 17 x 17, 17 x 16, 17 x 15.5, and 18 x 16 mm) while typing speed, error, fatigue, preference, forearm muscle activity, and wrist posture were recorded. Productivity and usability ratings were significantly worse for the keyboard with 15.5 mm vertical spacing compared to the other keyboards for both groups.There were few significant differences on usability ratings between the other keyboards. Reducing vertical key spacing,from 18 to 17 to 16 mm, had no significant effect on productivity or usability. The findings support the design of keyboards with vertical key spacings of 16, 17, or 18 mm. These findings may influence keyboard design and standards.

  20. SBIR-Long fluoride fiber

    NASA Astrophysics Data System (ADS)

    Jaeger, Raymond E.; Vacha, Lubos J.

    1987-08-01

    This report summarizes results obtained under a program aimed at developing new techniques for fabricating long lengths of heavy metal fluoride glass (HMFG) optical fiber. A new method for overcladding conventional HMFG preforms with a low melting oxide glass was developed, and improvements in the rotational casting method were made to increase preform length. The resulting composite glass canes consist of a fluoride glass overcoat layer to enhance strength and chemical durability. To show feasibility, prototype optical fiber preforms up to 1.6 cm in diameter with lengths of 22 cm were fabricated. These were drawn into optical fibers with lengths up to 900 meters.

  1. Women's Preferences for Penis Size: A New Research Method Using Selection among 3D Models

    PubMed Central

    Park, Jaymie; Leung, Shannon

    2015-01-01

    Women’s preferences for penis size may affect men’s comfort with their own bodies and may have implications for sexual health. Studies of women’s penis size preferences typically have relied on their abstract ratings or selecting amongst 2D, flaccid images. This study used haptic stimuli to allow assessment of women’s size recall accuracy for the first time, as well as examine their preferences for erect penis sizes in different relationship contexts. Women (N = 75) selected amongst 33, 3D models. Women recalled model size accurately using this method, although they made more errors with respect to penis length than circumference. Women preferred a penis of slightly larger circumference and length for one-time (length = 6.4 inches/16.3 cm, circumference = 5.0 inches/12.7 cm) versus long-term (length = 6.3 inches/16.0 cm, circumference = 4.8 inches/12.2 cm) sexual partners. These first estimates of erect penis size preferences using 3D models suggest women accurately recall size and prefer penises only slightly larger than average. PMID:26332467

  2. Women's Preferences for Penis Size: A New Research Method Using Selection among 3D Models.

    PubMed

    Prause, Nicole; Park, Jaymie; Leung, Shannon; Miller, Geoffrey

    2015-01-01

    Women's preferences for penis size may affect men's comfort with their own bodies and may have implications for sexual health. Studies of women's penis size preferences typically have relied on their abstract ratings or selecting amongst 2D, flaccid images. This study used haptic stimuli to allow assessment of women's size recall accuracy for the first time, as well as examine their preferences for erect penis sizes in different relationship contexts. Women (N = 75) selected amongst 33, 3D models. Women recalled model size accurately using this method, although they made more errors with respect to penis length than circumference. Women preferred a penis of slightly larger circumference and length for one-time (length = 6.4 inches/16.3 cm, circumference = 5.0 inches/12.7 cm) versus long-term (length = 6.3 inches/16.0 cm, circumference = 4.8 inches/12.2 cm) sexual partners. These first estimates of erect penis size preferences using 3D models suggest women accurately recall size and prefer penises only slightly larger than average.

  3. Numerical Investigations of an Optimized Airfoil with a Rotary Cylinder

    NASA Astrophysics Data System (ADS)

    Gada, Komal; Rahai, Hamid

    2015-11-01

    Numerical Investigations of an optimized thin airfoil with a rotary cylinder as a control device for reducing separation and improving lift to drag ratio have been performed. Our previous investigations have used geometrical optimization for development of an optimized airfoil with increased torque for applications in a vertical axis wind turbine. The improved performance was due to contributions of lift to torque at low angles of attack. The current investigations have been focused on using the optimized airfoil for micro-uav applications with an active flow control device, a rotary cylinder, to further control flow separation, especially during wind gust conditions. The airfoil has a chord length of 19.66 cm and a width of 25 cm with 0.254 cm thickness. Previous investigations have shown flow separation at approximately 85% chord length at moderate angles of attack. Thus the rotary cylinder with a 0.254 cm diameter was placed slightly downstream of the location of flow separation. The free stream mean velocity was 10 m/sec. and investigations have been performed at different cylinder's rotations with corresponding tangential velocities higher than, equal to and less than the free stream velocity. Results have shown more than 10% improvement in lift to drag ratio when the tangential velocity is near the free stream mean velocity. Graduate Assistant, Center for Energy and Environmental Research and Services (CEERS), College of Engineering, California State University, Long Beach.

  4. Mechanism of continence after repair of posterior urethral disruption: evidence of rhabdosphincter activity.

    PubMed

    Whitson, Jared M; McAninch, Jack W; Tanagho, Emil A; Metro, Michael J; Rahman, Nadeem U

    2008-03-01

    Controversy exists regarding continence mechanisms in patients who undergo posterior urethral reconstruction after pelvic fracture. Some evidence suggests that continence after posterior urethroplasty is maintained by the bladder neck or proximal urethral mechanism without a functioning distal mechanism. We studied distal urethral sphincter activity in patients who have undergone posterior urethroplasty for pelvic fracture. A total of 12 patients who had undergone surgical repair of urethral disruption involving the prostatomembranous region underwent videourodynamics with urethral pressure profiles at rest, and during stress and hold maneuvers. Bladder pressure and urethral pressure, including proximal and distal urethral sphincter activity and pressure, were assessed in each patient. All 12 patients had daytime continence of urine postoperatively with a followup after anastomotic urethroplasty of 12 to 242 months (mean 76). Average maximum urethral pressure was 71 cm H2O. Average maximum urethral closure pressure was 61 cm H2O. The average urethral pressure seen during a brief hold maneuver was 111 cm H2O. Average functional sphincteric length was 2.5 cm. Six of the 12 patients had clear evidence of distal urethral sphincter function, as demonstrated by the profile. Continence after anastomotic urethroplasty for posttraumatic urethral strictures is maintained primarily by the proximal bladder neck. However, there is a significant contribution of the rhabdosphincter in many patients.

  5. A case report of coup de sabre patient with hair transplantation.

    PubMed

    Dai, Yeqin; Xu, Ai-E; He, Junhua

    2017-09-01

    Treatment of coup de sabre must remain conservative until the disease is no longer in an active state. When activity has ceased, some operative intervention is safe and effective for the correction of deformity. While hair transplantation showed high survival rates for the correction of cicatricial alopecia, it has rarely reported to be performed for the correction of coup de sabre. To assess the therapeutic possibility of hair transplantation for the correction of coup de sabre. Follicular units consisting of two to three hairs from the patient's occipital scalp were transplanted and followed-up for 12 months. After 12 months of follow-up, treatment outcomes showed an 86.7% survival rate and 12-16 cm (mean 14 cm) length of the transplanted hairs. When coup de sabre is no longer in an active state, hair transplantation is a useful method for cosmetic improvement of the alopecia.

  6. Creation of short microwave ablation zones: in vivo characterization of single and paired modified triaxial antennas.

    PubMed

    Lubner, Meghan G; Ziemlewicz, Tim J; Hinshaw, J Louis; Lee, Fred T; Sampson, Lisa A; Brace, Christopher L

    2014-10-01

    To characterize modified triaxial microwave antennas configured to produce short ablation zones. Fifty single-antenna and 27 paired-antenna hepatic ablations were performed in domestic swine (N = 11) with 17-gauge gas-cooled modified triaxial antennas powered at 65 W from a 2.45-GHz generator. Single-antenna ablations were performed at 2 (n = 16), 5 (n = 21), and 10 (n = 13) minutes. Paired-antenna ablations were performed at 1-cm and 2-cm spacing for 5 (n = 7 and n = 8, respectively) and 10 minutes (n = 7 and n = 5, respectively). Mean transverse width, length, and aspect ratio of sectioned ablation zones were measured and compared. For single antennas, mean ablation zone lengths were 2.9 cm ± 0.45, 3.5 cm ± 0.55, and 4.2 cm ± 0.40 at 2, 5, and 10 minutes, respectively. Mean widths were 1.8 cm ± 0.3, 2.0 cm ± 0.32, and 2.5 cm ± 0.25 at 2, 5, and 10 minutes, respectively. For paired antennas, mean length at 5 minutes with 1-cm and 2-cm spacing and 10 minutes with 1-cm and 2-cm spacing was 4.2 cm ± 0.9, 4.9 cm ± 1.0, 4.8 cm ± 0.5, and 4.8 cm ± 1.3, respectively. Mean width was 3.1 cm ± 1.0, 4.4 cm ± 0.7, 3.8 cm ± 0.4, and 4.5 cm ± 0.7, respectively. Paired-antenna ablations were more spherical (aspect ratios, 0.72-0.79 for 5-10 min) than single-antenna ablations (aspect ratios, 0.57-0.59). For paired-antenna ablations, 1-cm spacing appeared optimal, with improved circularity and decreased clefting compared with 2-cm spacing (circularity, 0.85 at 1 cm, 0.78 at 2 cm). Modified triaxial antennas can generate relatively short, spherical ablation zones. Paired-antenna ablations were rounder and larger in transverse dimension than single antenna ablations, with 1-cm spacing optimal for confluence of the ablation zone. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  7. THE DIFFUSION LENGTH OF THERMAL NEUTRONS IN PORTLAND CONCRETE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dugdale, R.A.; Healy, E.

    1957-10-01

    A measurement of the diffusion length of thermal neutrons in Portland concrete, originally raade by Salmon two years previously, has been repeated. An apparent decrease from 7.04 cm to 6.61 cm has oocurred. This change, which is only four times the standard deviation of the result, could be due to a small increase in water content. In assessing the amount required, a discrepancy between calculated and measured diffusion length was found. Possible explanations of the discrepancy are discussed. (auth)

  8. Species Profiles: Life Histories and Environmental Requirements of Coastal Fishes and Invertebrates (Pacific Southwest). Pile Perch, Striped Seaperch, and Rubberlip Seaperch

    DTIC Science & Technology

    1989-07-01

    The largest of the teeth on vomer or palatines . surfperches, reaching a maximum length Branchiostegals 5-6; gill membranes of 47 cm TL (Eschmeyer et...Fritzsche 1982). dorsal surface. Fins dusky (Tarp 1952). Maximum length 44 cm total length (TL) (Eschmeyer et al. 1983). LIFE HISTORY Embiotoca lateralis...developed, shore. From 1958 to 1961, sport fused pharyngeal tooth plates that fishermen caught an estimated 5,000 enable the fish to crush hard-shelled

  9. Effects of saline drinking water on early gosling development

    USGS Publications Warehouse

    Stolley, D.S.; Bissonette, J.A.; Kadlec, J.A.; Coster, D.

    1999-01-01

    Relatively high levels of saline drinking water may adversely affect the growth, development, and survival of young waterfowl. Saline drinking water was suspect in the low survival rate of Canada goose (Branta canadensis) goslings at Fish Springs National Wildlife Refuge (FSNWR) in western Utah. Hence, we investigated the effects of saline drinking water on the survival and growth of captive, wild-strain goslings from day 1-28 following hatch. We compared survival and growth (as measured by body mass, wing length, and culmen length) between a control group on tap water with a mean specific conductivity of 650 ??S/cm, and 2 saline water treatments: (1) intermediate level (12,000 ??S/cm), and (2) high level (18,000 ??S/cm). Gosling mortality occurred only in the 18,000 ??S/cm treatment group (33%; n = 9). Slopes of regressions of mean body mass, wing length, and culmen length on age were different from each other (P < 0.05), except for culmen length for the intermediate and high treatment levels. We predict that free-ranging wild goslings will experience mortality at even lower salinity levels than captive goslings because of the combined effects of depressed growth and environmental stresses, including hot desert temperatures and variable food quality over summer.

  10. The impact of gastric distension on the lower esophageal sphincter and its exposure to acid gastric juice.

    PubMed

    Ayazi, Shahin; Tamhankar, Anand; DeMeester, Steven R; Zehetner, Joerg; Wu, Calvin; Lipham, John C; Hagen, Jeffrey A; DeMeester, Tom R

    2010-07-01

    The lower esophageal sphincter (LES) in patients with gastroesophageal reflux disease often has a low resting pressure and a short abdominal length. The mechanism by which this occurs is unknown. We hypothesize that gastric distension causes progressive effacement of the abdominal portion of the LES, exposing it to acid injury resulting in mucosal and sphincter damage. Our aim was to assess in normal subjects the effect of gastric distension on the LES length and pressure and its exposure to acid gastric juice. Eleven asymptomatic volunteers had their LES length and pressure measured before and during gastric distension. The location of the pH step-up point (shift from gastric pH to a pH >4) was also measured before and after distension. Progressive gastric distension with air resulted in progressive shortening of LES (R = 0.89, P < 0.0001). After infusion of 750 cc of air there was a significant reduction in the median LES length from 4 to 2.6 cm (P = 0.001). This change occurred in the abdominal length of the LES (2.6-1.4 cm [P = 0.001]) and not in the thoracic length. At rest the pH step-up point was 0.5 cm above the lower border of the LES and with distension moved a median of 1 cm cephalad within the LES. Simultaneously with the loss of length there was a reduction in LES pressure (27.4-23.4 mm Hg, P = 0.02). Gastric distension causes progressive shortening of the abdominal length of the LES and a reduction in its pressure. The process exposes the effaced mucosa and sphincter to acid gastric juice.

  11. Experiment of Burst Speed of Fingerling Masu salmon, Oncorhynchus, with Stamina Tunnel in The River

    NASA Astrophysics Data System (ADS)

    Izumi, Mattashi; Yamamoto, Yasuyuki; Yataya, Kenichi; Kamiyama, Kohhei

    A swimming experiment of cultured fingerling masu salmon (Oncorhynchus masou masou) (measuring 3cm to 6cm in length) was conducted in a round stamina tunnel (cylindrical pipe) installed in a fishway of a local river with a water flow velocity of 64cm·s-1 to 218cm·s-1 in order to study the burst speed of the masu salmon.The results show that: (1) the faster the swimming speed,the swimming time of the fingerling masu salmon shortened, and the ground speed also decreased as the flow velocity increased; (2)the faster the flow velocity,the shorter the swimming distance became; (3) the burst speed was calculated for the fingerling masu salmon with the considerably excellent swimming ability(measuring 4.6cm to 6.2cm in mean length) in conditions of a high velocity(218cm·s-1), and the result was: mean burst speed:229cm·s-1(S.D.8cm·s-1) to 232cm·s-1(S.D.:8cm·s-1).

  12. [Arthrodesis without bone fusion with an intramedullary modular nail for revision of infected total knee arthroplasty].

    PubMed

    Miralles-Muñoz, F A; Lizaur-Utrilla, A; Manrique-Lipa, C; López-Prats, F A

    2014-01-01

    To evaluate the outcome of knee fixation without bone fusion using an intramedullary modular nail and interposed cement. Retrospective study of 29 infected total knee arthroplasties with prospective data collection and a mean follow-up of 4.2 years (3-5). Complications included 2 recurrent infections, 1 peri-implant fracture, and 1 cortical erosion due to the tip of the femoral component. All of these were revised with successful results. The mean limb length discrepancy was 0.8 cm, with 24<1cm. Twenty-five patients reported no pain. The mean WOMAC-pain was 86.9, WOMAC-function 56.4, SF12-physical 45.1, and SF12-mental 53.7. Four patients needed a walking frame, and only two were dependent for daily activities. The Endo-Model Link nail is an effective method for knee fixation that restores the anatomical alignment of the limb with adequate leg length. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  13. Experimental study on burning rates of square/rectangular gasoline and methanol pool fires under longitudinal air flow in a wind tunnel.

    PubMed

    Hu, L H; Liu, S; Peng, W; Huo, R

    2009-09-30

    Square pool fires with length of 5, 7.5, 10, 15, 20, 25 and 30 cm and rectangular pool fires with dimensions of 10 cm x 20 cm and 10 cm x 40 cm were burned in a wind tunnel, under a longitudinal air flow ranged from 0 to 3m/s with incremental change of about 0.5m/s. Methanol and gasoline were burned and compared, with results indicated that their burning rates showed different response to the longitudinal air flow. With the increase of the longitudinal air flow speed, the burning rates of methanol pool fires, except the 5 cm square one, first decreased and then increased, but those of the 5 cm methanol square one and the gasoline pool fires increased monotonously. The burning rate of smaller square pool fires increased more significantly than that of the larger ones, as well as the enlargement of their flame attachment length along the ground. The burning rate of a rectangular pool fire with longer rim parallel to the longitudinal flow increased faster, but the flame attachment length seemed to increase more gradually, with the increase of the longitudinal air flow speed than that perpendicular to.

  14. Diffusion lengths in irradiated N/P InP-on-Si solar cells

    NASA Technical Reports Server (NTRS)

    Wojtczuk, Steven; Colerico, Claudia; Summers, Geoffrey P.; Walters, Robert J.; Burke, Edward A.

    1996-01-01

    Indium phosphide (InP) solar cells were made on silicon (Si) wafers (InP/Si) by to take advantage of both the radiation-hardness properties of the InP solar cell and the light weight and low cost of Si wafers. The InP/Si cell application is for long duration and/or high radiation orbit space missions. Spire has made N/P InP/Si cells of sizes up to 2 cm by 4 cm with beginning-of-life (BOL) AM0 efficiencies over 13% (one-sun, 28C). These InP/Si cells have higher absolute efficiency and power density after a high radiation dose than gallium arsenide (GaAs) or silicon (Si) solar cells after a fluence of about 2e15 1 MeV electrons/sq. cm. In this work, we investigate the minority carrier (electron) base diffusion lengths in the N/P InP/Si cells. A quantum efficiency model was constructed for a 12% BOL AM0 N/P InP/Si cell which agreed well with the absolutely measured quantum efficiency and the sun-simulator measured AM0 photocurrent (30.1 mA/sq. cm). This model was then used to generate a table of AM0 photocurrents for a range of base diffusion lengths. AM0 photocurrents were then measured for irradiations up to 7.7e16 1 MeV electrons/sq. cm (the 12% BOL cell was 8% after the final irradiation). By comparing the measured photocurrents with the predicted photocurrents, base diffusion lengths were assigned at each fluence level. A damage coefficient K of 4e-8 and a starting (unirradiated) base electron diffusion length of 0.8 microns fits the data well. The quantum efficiency was measured again at the end of the experiment to verify that the photocurrent predicted by the model (25.5 mA/sq. cm) agreed with the simulator-measured photocurrent after irradiation (25.7 mA/sq. cm).

  15. 16 CFR § 1220.1 - Scope, compliance dates, and definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... affecting commerce and other purposes; (iii) Has an interior length dimension either greater than 139.7 cm (55 in.) or smaller than 126.3 cm (49 3/4 in.), or, an interior width dimension either greater than 77... components. (D) Undersize crib—a non-full-size baby crib with an interior length dimension smaller than 126.3...

  16. 16 CFR 1220.1 - Scope, compliance dates, and definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... affecting commerce and other purposes; (iii) Has an interior length dimension either greater than 139.7 cm (55 in.) or smaller than 126.3 cm (49 3/4 in.), or, an interior width dimension either greater than 77... components. (D) Undersize crib—a non-full-size baby crib with an interior length dimension smaller than 126.3...

  17. 16 CFR 1220.1 - Scope, compliance dates, and definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... affecting commerce and other purposes; (iii) Has an interior length dimension either greater than 139.7 cm (55 in.) or smaller than 126.3 cm (49 3/4 in.), or, an interior width dimension either greater than 77... components. (D) Undersize crib—a non-full-size baby crib with an interior length dimension smaller than 126.3...

  18. 50 CFR 660.704 - Vessel identification.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF COMMERCE (CONTINUED) FISHERIES OFF WEST COAST STATES Highly Migratory Fisheries... (25.40 cm) in height for vessels more than 25 ft (7.62 m) but equal to or less than 65 ft (19.81 m) in length; and 18 inches (45.72 cm)in height for vessels longer than 65 ft (19.81 m) in length. Markings...

  19. The influence of curvature configuration on the characteristic of alcohol gel insertion jacket of polymer optical fiber liquid level sensor

    NASA Astrophysics Data System (ADS)

    Arumnika, N.; Kuswanto, H.

    2018-04-01

    This study aimed to determine the effect of curvature configuration to sensitivities and linearities of Polymer Optical Fiber (POF) water level sensor. POF type SH-4001-1.3 has been used in this study. The jacket of POF of 20 cm was removed. Transparent piped inserted by alcohol gel has been used to replace the jacket. This is head of a sensor. The head of a sensor is curved with variations of the specified path length, peel length, the width of curvature, the height of curvature and waveform. Configuration A (20 cm, 34 cm, 6 cm, 2 cm, 1 wave), configuration B (20 cm, 34 cm, 8 cm, 2 cm, 1 wave), configuration C (20 cm, 34 cm, 9 cm, 2 cm, ½ wave), configuration D (20 cm, 34 cm, 10 cm, 2 cm, ½ wave). The head of a sensor inserted into the water tank. The light source inserted to one end POF is a He-Ne laser light with a power of 5 mW and a wavelength of 632.8 nm. Power output at the other end received by the Optical Power Meter (OPM). The curvature configuration the head sensor of POF affects the output. Configuration A has good sensitivity, however good linearity given by configuration.

  20. Evaluation of Kidney Stones with Reduced-Radiation Dose CT: Progress from 2011-2012 to 2015-2016-Not There Yet.

    PubMed

    Weisenthal, Karrin; Karthik, Priyadarshini; Shaw, Melissa; Sengupta, Debapriya; Bhargavan-Chatfield, Mythreyi; Burleson, Judy; Mustafa, Adel; Kalra, Mannudeep; Moore, Christopher

    2018-02-01

    Purpose To determine if the use of reduced-dose computed tomography (CT) for evaluation of kidney stones increased in 2015-2016 compared with that in 2011-2012, to determine variability in radiation exposure according to facility for this indication, and to establish a current average radiation dose for CT evaluation for kidney stones by querying a national dose registry. Materials and Methods This cross-sectional study was exempt from institutional review board approval. Data were obtained from the American College of Radiology dose registry for CT examinations submitted from July 2015 to June 2016. Study descriptors consistent with single-phase unenhanced CT for evaluation of kidney stones and associated RadLex® Playbook identifiers (RPIDs) were retrospectively identified. Facilities actively submitting data on kidney stone-specific CT examinations were included. Dose metrics including volumetric CT dose index, dose-length product, and size-specific dose estimate, when available, were reported, and a random effects model was run to account for clustering of CT examinations at facilities. A z-ratio was calculated to test for a significant difference between the proportion of reduced-radiation dose CT examinations (defined as those with a dose-length product of 200 mGy · cm or less) performed in 2015-2016 and the proportion performed in 2011-2012. Results Three hundred four study descriptors for kidney stone CT corresponding to data from 328 facilities that submitted 105 334 kidney stone CT examinations were identified. Reduced-dose CT examinations accounted for 8040 of 105 334 (7.6%) CT examinations, a 5.6% increase from the 1010 of 49 903 (2%) examinations in 2011-2012 (P < .001). Mean overall dose-length product was 689 mGy · cm (95% confidence interval: 667, 712), decreased from the mean of 746 mGy · cm observed in 2011-2012. Median facility dose-length product varied up to sevenfold, from less than 200 mGy · cm to greater than 1600 mGy · cm. Conclusion Use of reduced-radiation dose CT for evaluation of kidney stones has increased since 2011-2012, but remains low; variability of radiation dose according to facility continues to be wide. National mean CT radiation exposure for evaluation of renal colic during 2015-2016 decreased relative to 2011-2012 values, but remained well above what is reasonably achievable. © RSNA, 2017.

  1. 50 CFR 648.83 - Multispecies minimum fish sizes.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... vessels are subject to the following minimum fish sizes, determined by total length (TL): Minimum Fish Sizes (TL) for Commercial Vessels Species Size(inches) Cod 22 (55.9 cm) Haddock 18 (45.7 cm) Pollock 19 (48.3 cm) Witch flounder (gray sole) 14 (35.6 cm) Yellowtail flounder 13 (33.0 cm) American plaice...

  2. 50 CFR 648.83 - Multispecies minimum fish sizes.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... vessels are subject to the following minimum fish sizes, determined by total length (TL): Minimum Fish Sizes (TL) for Commercial Vessels Species Size(inches) Cod 19 (48.3 cm) Haddock 16 (40.6 cm) Pollock 19 (48.3 cm) Witch flounder (gray sole) 13 (33 cm) Yellowtail flounder 12 (30.5 cm) American plaice (dab...

  3. 50 CFR 648.83 - Multispecies minimum fish sizes.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... vessels are subject to the following minimum fish sizes, determined by total length (TL): Minimum Fish Sizes (TL) for Commercial Vessels Species Size(inches) Cod 19 (48.3 cm) Haddock 16 (40.6 cm) Pollock 19 (48.3 cm) Witch flounder (gray sole) 13 (33 cm) Yellowtail flounder 12 (30.5 cm) American plaice (dab...

  4. 50 CFR 648.83 - Multispecies minimum fish sizes.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... vessels are subject to the following minimum fish sizes, determined by total length (TL): Minimum Fish Sizes (TL) for Commercial Vessels Species Size(inches) Cod 22 (55.9 cm) Haddock 18 (45.7 cm) Pollock 19 (48.3 cm) Witch flounder (gray sole) 14 (35.6 cm) Yellowtail flounder 13 (33.0 cm) American plaice...

  5. Kinetic study of cytochrome P450 3A4 activity on warfarin by capillary electrophoresis with fluorescence detection.

    PubMed

    Zhang, Jie; Ha, Pham Thi Thanh; Lou, Yijia; Hoogmartens, Jos a; Van Schepdael, Ann

    2005-08-05

    The use of capillary electrophoresis (CE) for the determination of cytochrome P450 3A4 (CYP3A4) activity with R-warfarin as a substrate was investigated. CYP3A4 activity was determined by the quantitation of the product, 10-hydroxywarfarin, based on separation by CE. The separation conditions were as follows: capillary, 80.5 cm (75 microm i.d., 60 cm effective length); 50 mM sodium phosphate buffer (pH 6.5); 23 kV (90 microA) applied voltage; fluorescence detection, excitation wavelength, 310 nm, emission wavelength, 418 nm; capillary temperature, 37 degrees C. With the developed CYP3A4 activity assay and the Lineweaver-Burk equation, the Michaelis-Menten parameters Km and Vmax for formation of 10-hydroxywarfarin from R-warfarin in the presence of CYP3A4 were calculated to be 166 +/- 12 microM and 713 +/- 14 pmol/min/nmol (or 91.4 pmol/min/mg) CYP3A4, respectively.

  6. Grey water treatment in urban slums by a filtration system: optimisation of the filtration medium.

    PubMed

    Katukiza, A Y; Ronteltap, M; Niwagaba, C B; Kansiime, F; Lens, P N L

    2014-12-15

    Two uPVC columns (outer diameter 160 cm, internal diameter 14.6 cm and length 100 cm) were operated in parallel and in series to simulate grey water treatment by media based filtration at unsaturated conditions and constant hydraulic loading rates (HLR). Grey water from bathroom, laundry and kitchen activities was collected from 10 households in the Bwaise III slum in Kampala (Uganda) in separate containers, mixed in equal proportions followed by settling, prior to transferring the influent to the tanks. Column 1 was packed with lava rock to a depth of 60 cm, while column 2 was packed with lava rock (bottom 30 cm) and silica sand, which was later replaced by granular activated carbon (top 30 cm) to further investigate nutrient removal from grey water. Operating the two filter columns in series at a HLR of 20 cm/day resulted in a better effluent quality than at a higher (40 cm/day) HLR. The COD removal efficiencies by filter columns 1 and 2 in series amounted to 90% and 84% at HLR of 20 cm/day and 40 cm/day, respectively. TOC and DOC removal efficiency amounted to 77% and 71% at a HLR of 20 cm/day, but decreased to 72% and 67% at a HLR of 40 cm/day, respectively. The highest log removal of Escherichia coli, Salmonella sp. and total coliforms amounted to 3.68, 3.50 and 3.95 at a HLR of 20 cm/day respectively. The overall removal of pollutants increased with infiltration depth, with the highest pollutant removal efficiency occurring in the top 15 cm layer. Grey water pre-treatment followed by double filtration using coarse and fine media has the potential to reduce the grey water pollution load in slum areas by more than 60%. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Development of the areola in the early placenta of the one-humped camel (Camelus dromedarius): a light, scanning and transmission electron microscopical study.

    PubMed

    Abd-Elnaeim, M M M; Saber, A; Hassan, A; Abou-Elmagd, A; Klisch, K; Jones, C J P; Leiser, R

    2003-12-01

    This study aimed to elucidate development of the areola in the early dromedary placenta in comparison with that of the pig and mare. Placental tissues from 25 pregnant camels were obtained from Cairo abattoir and prepared for light, scanning and transmission electron microscopy by routine methods. Vascular casts were made by injection of 4 : 1 liquid plastic mixture of mercox and methylmethacrylate. Areolar formation was first observed at 4.5 cm curved-crown-rump CVR length, while by 5-9 cm CVR length, the endometrial surface was uneven and studded with numerous uterine gland openings, where corresponding foetal areolae were barely detectable and the foetal areolar cells were of variable appearance and covered with long microvilli. At 10-13 cm CVR length the uterine gland openings developed irregular folds and the maternal areolar cells showed numerous apical blebs. At 14-29 cm CVR length the foetal areolae showed a great increase in height at the expense of their width. At 30-34 cm (CVR) length the maternal areolae appeared discoid and sharply demarcated from the surrounding inter-areolar tissues and the foetal areolae were rounded to irregular in shape with well-developed areolar rims. The vascular casts showed a widely meshed capillary network on the maternal areola, connecting with the pre- and post-capillary vessels, whereas the foetal side showed a relatively dense capillary meshwork. These studies indicate that the areola in the placenta of the one-humped camel is of the regular type like in the pig, and is poorly vascularized.

  8. In situ growth rates of deep-water octocorals determined from 3D photogrammetric reconstructions

    NASA Astrophysics Data System (ADS)

    Bennecke, Swaantje; Kwasnitschka, Tom; Metaxas, Anna; Dullo, Wolf-Christian

    2016-12-01

    Growth rates of deep-water corals provide important information on the recovery potential of these ecosystems, for example from fisheries-induced impacts. Here, we present in situ growth dynamics that are currently largely unknown for deep-water octocorals, calculated by applying a non-destructive method. Videos of a boulder harbouring multiple colonies of Paragorgia arborea and Primnoa resedaeformis in the Northeast Channel Coral Conservation Area at the entrance to the Gulf of Maine at 863 m depth were collected in 2006, 2010 and 2014. Photogrammetric reconstructions of the boulder and the fauna yielded georeferenced 3D models for all sampling years. Repeated measurements of total length and cross-sectional area of the same colonies allowed the observation of growth dynamics. Growth rates of total length of Paragorgia arborea decreased over time with higher rates between 2006 and 2010 than between 2010 and 2014, while growth rates of cross-sectional area remained comparatively constant. A general trend of decreasing growth rates of total length with size of the coral colony was documented. While no growth was observed for the largest colony (165 cm in length) between 2010 and 2014, a colony 50-65 cm in length grew 3.7 cm yr-1 between 2006 and 2010. Minimum growth rates of 1.6-2.7 cm yr-1 were estimated for two recruits (<23 cm in 2014) of Primnoa resedaeformis. We successfully extracted biologically meaningful data from photogrammetric models and present the first in situ growth rates for these coral species in the Northwest Atlantic.

  9. [Growth in terms of length of Chilean infants of low socioeconomic status: 1978-1992].

    PubMed

    Pizarro, F; Olivares, M; Hertrampf, E; Walter, T

    1996-06-01

    In Chile infant malnutrition is better reflected by the length/age indicator than by weight/length. In this study we will present the progression of length during the first year of life from the year 1978 through 1992 of infants of low socioeconomic status. We selected healthy infants with > 3000 g birth weight and birth length > 0.5 z. According to type of milk feedings they were defined as CM (cow milk) those who were weaned before 4 months of life and EM (exclusive breast milk) those who continued exclusive breast milk (as only source of milk solids permitted) past 6 months. Infants CM of the 1978-80 cohort had a length at birth z +0.21 reaching 1 year with z -0.65, a loss of 0.86 z. Infants from the cohorts of 1982-86 and 1988-92 fell from z +0.15 to z -0.37 (a loss of -0.52 z) and +0.16 to -0.19 (a loss of -0.45 z) between birth and 12 months respectively. EBM infants length also fell significantly (delta z: -1.12, -0.69 and 0.59 respectively). Proteincalorie nutrition was adequate confirmed with weight/age or length/weight curves with means of +0.52 throughout the first year. Analysis of the length curves by regression shows that the slopes of the 3 cohorts are significantly different (< 0.01) for CM and EBM favoring the most recent cohorts. Multiple regression analysis identified association of length at 1 year with birth weight (p < 0.05), birth length (p < 0.01) and socioeconomic index (p < 0.01). We suggest that there is an improvement in the trend of Chilean infants growth in length for the past 20 years, likely due to improvement in socioeconomic level.

  10. Effect of root length on epicotyl dormancy release in seeds of Paeonia ludlowii, Tibetan peony.

    PubMed

    Hao, Hai-ping; He, Zhi; Li, Hui; Shi, Lei; Tang, Yu-Dan

    2014-02-01

    Epicotyl dormancy break in seeds that have deep simple epicotyl morphophysiological dormancy (MPD) requires radicle emergence and even a certain root length in some species. However, the mechanisms by which root length affects epicotyl dormancy break are not clear at present. This study aims to explore the relationship between root length and epicotyl dormancy release in radicle-emerged seeds of Tibetan peony, Paeonia ludlowii, with discussion of the possible mechanisms. Radicle-emerged seeds (radicle length 1.5, 3.0, 4.5 and 6.0 cm) were incubated at 5, 10 and 15 °C. During the stratification, some seeds were transferred to 15 °C and monitored for epicotyl-plumule growth. Hormone content was determined by ELISA, and the role of hormones in epicotyl dormancy release was tested by exogenous hormone and embryo culture. Cold stratification did not break the epicotyl dormancy until the root length was ≥6 cm. The indole-3-actic acid (IAA) and GA3 contents of seeds having 6 cm roots were significantly higher than those of seeds with other root lengths, but the abscisic acid (ABA) content was lowest among radicle-emerged seeds. GA3 (400 mg L(-1)) could break epicotyl dormancy of all radicle-emerged seeds, while IAA (200 mg L(-1)) had little or no effect. When grown on MS medium, radicles of naked embryos grew and cotyledons turned green, but epicotyls did not elongate. Naked embryos developed into seedlings on a mixed medium of MS + 100 mg L(-1) GA3. A root length of ≥6.0 cm is necessary for epicotyl dormancy release by cold stratification. The underlying reason for root length affecting epicotyl dormancy release is a difference in the GA3/ABA ratio in the epicotyl within radicle-emerged seeds, which is mainly as a result of a difference in ABA accumulation before cold stratification.

  11. Effect of root length on epicotyl dormancy release in seeds of Paeonia ludlowii, Tibetan peony

    PubMed Central

    Hao, Hai-ping; He, Zhi; Li, Hui; Shi, Lei; Tang, Yu-Dan

    2014-01-01

    Background and Aims Epicotyl dormancy break in seeds that have deep simple epicotyl morphophysiological dormancy (MPD) requires radicle emergence and even a certain root length in some species. However, the mechanisms by which root length affects epicotyl dormancy break are not clear at present. This study aims to explore the relationship between root length and epicotyl dormancy release in radicle-emerged seeds of Tibetan peony, Paeonia ludlowii, with discussion of the possible mechanisms. Methods Radicle-emerged seeds (radicle length 1·5, 3·0, 4·5 and 6·0 cm) were incubated at 5, 10 and 15 °C. During the stratification, some seeds were transferred to 15 °C and monitored for epicotyl–plumule growth. Hormone content was determined by ELISA, and the role of hormones in epicotyl dormancy release was tested by exogenous hormone and embryo culture. Key Results Cold stratification did not break the epicotyl dormancy until the root length was ≥6 cm. The indole-3-actic acid (IAA) and GA3 contents of seeds having 6 cm roots were significantly higher than those of seeds with other root lengths, but the abscisic acid (ABA) content was lowest among radicle-emerged seeds. GA3 (400 mg L−1) could break epicotyl dormancy of all radicle-emerged seeds, while IAA (200 mg L−1) had little or no effect. When grown on MS medium, radicles of naked embryos grew and cotyledons turned green, but epicotyls did not elongate. Naked embryos developed into seedlings on a mixed medium of MS + 100 mg L−1 GA3. Conclusions A root length of ≥6·0 cm is necessary for epicotyl dormancy release by cold stratification. The underlying reason for root length affecting epicotyl dormancy release is a difference in the GA3/ABA ratio in the epicotyl within radicle-emerged seeds, which is mainly as a result of a difference in ABA accumulation before cold stratification. PMID:24284815

  12. 50 CFR 32.28 - Florida.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... one bass may be over 14 inches (35 cm) in length. 3. We allow fishing south of a line of latitude of... archery season. 18. Hunters may take deer, with one or more antlers at least 5 inches (12.5 cm) in length... limited deer gun hunt and limited youth gun deer hunt, except only one deer may be a buck for each of the...

  13. The estimation of the propagation delay through the troposphere from microwave radiometer data. [very long base interferometry

    NASA Technical Reports Server (NTRS)

    Moran, J. M.; Rosen, B. R.

    1980-01-01

    The uncertainity in propagation delay estimates is due primarily to tropospheric water, the total amount and vertical distribution of which is variable. Because water vapor both delays and attenuates microwave signals, the propagation delay, or wet path length, can be estimated from the microwave brightness temperature near the 22.235 GHz transition of water vapor. The data from a total of 240 radiosonde launches taken simultaneously were analyzed. Estimates of brightness temperature at 19 and 22 GHz and wet path length were made from these data. The wet path length in the zenith direction could be estimated from the surface water vapor density to an accuracy of 5 cm for the summer data and 2 cm for winter data. Using the brightness temperatures, the wet path could be estimated to an accuracy of 0.3 cm. Two dual frequency radiometers were refurbished in order to test these techniques. These radiometers were capable of measuring the difference in the brightness temperature at 30 deg elevation angle and at the zenith to an accuracy of about 1 K. In August 1975, 45 radiosondes were launched over an 11 day period. Brightness temperature measurements were made simultaneously at 19 and 22 GHz with the radiometers. The rms error for the estimation of wet path length from surface meteorological parameters was 3.2 cm, and from the radiometer brightness temperatures, 1.5 cm.

  14. Effects of antenna length and material on output power and detection of miniature radio transmitters

    USGS Publications Warehouse

    Beeman, J.W.; Bower, N.; Juhnke, S.; Dingmon, L.; Van Den, Tillaart; Thomas, T.

    2007-01-01

    The optimal antenna of transmitters used in small aquatic animals is often a compromise between efficient radio wave propagation and effects on animal behavior. Radio transmission efficiency generally increases with diameter and length of the conductor, but increased antenna length or weight can adversely affect animal behavior. We evaluated the effects of changing antenna length and material on the subsequent tag output power, reception, and detection of tagged fish. In a laboratory, we compared the relative signal strengths in water of 150 MHz transmitters over a range of antenna lengths (from 6 to 30 cm) and materials (one weighing about half of the other). The peak relative signal strengths were at 20 and 22 cm, which are approximately one wavelength underwater at the test frequency. The peak relative signal strengths at these lengths were approximately 50% greater than those of 30 cm antennas, a length commonly used in fisheries research. Few significant differences were present in distances for the operator to hear or the telemetry receiver to decode transmitters from a boat-mounted receiving system based on antenna length, but the percent of tagged fish detected passing a hydroelectric dam fitted with an array of receiving systems was significantly greater at the antenna length with peak output power in laboratory tests. This study indicates careful choice of antenna length and material of small transmitters can be used to reduce weight and possible antenna effects on animal behavior, to maximize tag output power and detection, or to balance these factors based on the needs of the application. ?? 2007 Springer Science+Business Media B.V.

  15. Model predictions for atmospheric air breakdown by radio-frequency excitation in large gaps

    NASA Astrophysics Data System (ADS)

    Nguyen, H. K.; Mankowski, J.; Dickens, J. C.; Neuber, A. A.; Joshi, R. P.

    2017-07-01

    The behavior of the breakdown electric field versus frequency (DC to 100 MHz) for different gap lengths has been studied numerically at atmospheric pressure. Unlike previous reports, the focus here is on much larger gap lengths in the 1-5 cm range. A numerical analysis, with transport coefficients obtained from Monte Carlo calculations, is used to ascertain the electric field thresholds at which the growth and extinction of the electron population over time are balanced. Our analysis is indicative of a U-shaped frequency dependence, lower breakdown fields with increasing gap lengths, and trends qualitatively similar to the frequency-dependent field behavior for microgaps. The low frequency value of ˜34 kV/cm for a 1 cm gap approaches the reported DC Paschen limit.

  16. Describing differences in weight and length growth trajectories between white and Pakistani infants in the UK: analysis of the Born in Bradford birth cohort study using multilevel linear spline models.

    PubMed

    Fairley, Lesley; Petherick, Emily S; Howe, Laura D; Tilling, Kate; Cameron, Noel; Lawlor, Debbie A; West, Jane; Wright, John

    2013-04-01

    To describe the growth pattern from birth to 2 years of UK-born white British and Pakistani infants. Birth cohort. Bradford, UK. 314 white British boys, 383 Pakistani boys, 328 white British girls and 409 Pakistani girls. Weight and length trajectories based on repeat measurements from birth to 2 years. Linear spline multilevel models for weight and length with knot points at 4 and 9 months fitted the data well. At birth Pakistani boys were 210 g lighter (95% CI -290 to -120) and 0.5 cm shorter (-1.04 to 0.02) and Pakistani girls were 180 g lighter (-260 to -100) and 0.5 cm shorter (-0.91 to -0.03) than white British boys and girls, respectively. Pakistani infants gained length faster than white British infants between 0 and 4 months (+0.3 cm/month (0.1 to 0.5) for boys and +0.4 cm/month (0.2 to 0.6) for girls) and gained more weight per month between 9 and 24 months (+10 g/month (0 to 30) for boys and +30 g/month (20 to 40) for girls). Adjustment for maternal height attenuated ethnic differences in weight and length at birth, but not in postnatal growth. Adjustment for other confounders did not explain differences in any outcomes. Pakistani infants were lighter and had shorter predicted mean length at birth than white British infants, but gained weight and length quicker in infancy. By age 2 years both ethnic groups had similar weight, but Pakistani infants were on average taller than white British infants.

  17. Towards GPS orbit accuracy of tens of centimeters

    NASA Technical Reports Server (NTRS)

    Lichten, Stephen M.

    1990-01-01

    In this paper, CASA Uno orbit results are presented utilizing data from four continents. Refinements in orbit modeling, combined with the availability of a worldwide tracking network and the dense distribution of tracking sites in North and South America, have improved orbit determination precision to about 60 cm (per component) for four of the seven GPS satellites tracked in CASA Uno. The orbit results are consistent with California baseline repeatabilities, which are at the few mm level in horizontal and length, and 1-2 cm in the vertical. Baseline comparisons with VLBI provide a measure of orbit accuracy, showing sub-cm agreement in length and 1.5 cm agreement in the horizontal.

  18. Nonlinear optical properties of flux growth KTiOPO4

    NASA Astrophysics Data System (ADS)

    Stolzenberger, Richard A.

    1988-09-01

    The properties of large flux grown KTiOPO4 second harmonic generators were measured. A technique which provides a sensitive assessment of crystal uniformity is described. Optically perfect second harmonic generation crystals of up to 1 cu cm were found to have nonlinear optical properties comparable with those grown by other methods. A Q-switched Nd:YAG laser was used to determine temperature acceptance width-length product (20 C cm), angular acceptance width-length product (13 mrad cm), and doubling efficiency (50 percent). Spectral bandwidth (4.5 A cm) and wavefront distortion (1/4 wave at 633 nm) were also measured. The dependence of these properties on crystal homogeneity is demonstrated.

  19. Laser guiding of Tesla coil high voltage discharges.

    PubMed

    Henriksson, Markus; Daigle, Jean-Francois; Théberge, Francis; Châteauneuf, Marc; Dubois, Jacques

    2012-06-04

    We have investigated the guiding and triggering of discharges from a Tesla coil type 280 kHz AC high voltage source using filaments created by a femtosecond Terawatt laser pulse. Without the laser the discharges were maximum 30 cm long. With the laser straight, guided discharges up to 110 cm length were detected. The discharge length was limited by the voltage amplitude of the Tesla coil.

  20. 16 CFR 500.12 - Measurement of commodities by length and width, how expressed.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... remainder in inches or common or decimal fractions of the yard or foot except that a dimension of less than... dimension of less than 2 feet (60.96 cm) may be stated in inches. (4) For any commodity for which the... square foot (929 cm2) be expressed in terms of length and width in linear measure. The customary inch...

  1. Maternal body burden of cadmium and offspring size at birth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romano, Megan E., E-mail: megan_romano@brown.edu; Enquobahrie, Daniel A.; Center for Perinatal Studies, Swedish Medical Center, Seattle, WA

    Increasing evidence suggests an inverse association between cadmium (Cd) and size at birth, potentially greatest among female neonates. We evaluated whether greater maternal body burden of Cd is associated with reduced neonatal anthropometry (birthweight, birth length, head circumference, and ponderal index) and assessed whether these associations differ by infant sex. The analytic sample for the present study (n=396) was derived from a subcohort of 750 women randomly drawn from among all participants (N=4344) in the Omega Study, a prospective pregnancy cohort. Creatinine-corrected Cd in maternal clean-catch spot urine samples (U-Cd) was quantified by inductively coupled plasma mass spectrometry. Continuous log{submore » 2}-transformed Cd (log{sub 2}-Cd) and U-Cd tertiles (low<0.29 μg/g creatinine, middle 0.29–0.42 μg/g creatinine, high≥0.43 μg/g creatinine) were used in multivariable linear regression models. Females had reduced birth length with greater U-Cd tertile, whereas males birth length marginally increased [β(95% CI) females: low=reference, middle=−0.59 cm (−1.37, 0.19), high=−0.83 cm (−1.69, 0.02), p-trend=0.08; males: low=reference, middle=0.18 cm (−0.59, 0.95), high=0.78 cm (–0.04, 1.60), p-trend=0.07; p for interaction=0.03]. The log{sub 2}-Cd by infant sex interaction was statistically significant for ponderal index [p=0.003; β(95% CI): female=0.25 kg/m{sup 3} (−0.20, 0.70); male=−0.63 kg/m{sup 3} (−1.01, −0.24)] and birth length [p<0.001; β(95% CI): female=−0.47 cm (−0.74, −0.20), male=0.32 cm (0.00, 0.65)]. Our findings suggest potential sex-specific reversal of Cd’s associations on birth length and contribute to the evidence suggesting Cd impairs fetal growth. - Highlights: • Cadmium levels in the general population potentially adversely affect size at birth. • Maternal urinary cadmium was inversely related to birth length among female infants. • For male infants, maternal cadmium was positively associated with birth length. • Maternal cadmium was also inversely related to ponderal index among male infants.« less

  2. Beam test of novel n-in-p strip sensors for high radiation environment

    NASA Astrophysics Data System (ADS)

    Kubota, T.; Kishida, T.; Jinnouchi, O.; Ikegami, Y.; Unno, Y.; Terada, S.; Mitsui, S.; Tamii, A.; Aoi, T.; Hanagaki, K.; Hara, K.; Kimura, N.; Takashima, R.; Takubo, Y.; Tojo, J.; Nagai, K.; Nakano, I.; Yorita, K.

    2013-12-01

    Highly radiation tolerant n-in-p strip sensors have been developed for the high-luminosity LHC (HL-LHC). This paper reports the results of measurements with 392 MeV kinetic energy proton beam at RCNP in December 2011. The data was taken with a new DAQ system consisting of an universal read-out board ‘SEABAS’ and beam tracking telescopes whose spacial resolution is better than 5 μm. The aim of this beam test is to evaluate the new 1 cm×1 cm n-in-p miniature sensors before and after 1015 neq cm-2 irradiation. The median charge of un-irradiated sensor is 6.2 fC at full depletion voltage, while the median charge after 1015 neq cm-2 irradiation of the sensor is 4.2 fC. The novel Punch-Through-Protection (PTP) has been implemented in these sensors. The length of active region of the sensor around PTP is observed to be decreased by 12 μm in the irradiated sensors at 1015 neq cm-2.

  3. Maternal smoking during pregnancy and genetic polymorphisms in the Ah receptor, CYP1A1 and GSTM1 affect infant birth size in Japanese subjects.

    PubMed

    Sasaki, S; Kondo, T; Sata, F; Saijo, Y; Katoh, S; Nakajima, S; Ishizuka, M; Fujita, S; Kishi, R

    2006-02-01

    Genetic susceptibility to tobacco smoke might have relation to adverse pregnancy outcomes. To estimate the effects of maternal smoking and genetic polymorphisms on infant birth weight and length, we conducted a prospective cohort study of 293 women who delivered singleton live births in Sapporo, Japan. Birth weight and length were significantly lower among infants born to continuously smoking women having the aryl hydrocarbon receptor (AhR) wild type genotype (Arg/Arg; 211 g +/- 76 g; 1.2 cm +/- 0.4 cm, p < 0.01 and p < 0.01, respectively), the CYP1A1 variant genotype (m1/m2 + m2/m2; 170 g +/- 64 g, 0.8 cm +/- 0.3 cm, p < 0.01 and p < 0.05, respectively), or the GSTM1 null genotype (171 g +/- 58 g, 0.6 cm +/- 0.3 cm, p < 0.01 and p < 0.05, respectively). When combinations of these genotypes were considered, birth weight and length were significantly lower for infants of continuously smoking women in the AhR wild type + CYP1A1 variant group (315 g +/- 116 g; 1.7 cm +/- 0.6 cm, p < 0.01 and p < 0.01, respectively) and in the CYP1A1 variant + GSTM1 null group (237 g +/- 92 g; 1.3 cm +/- 0.5 cm, p < 0.05 and p < 0.01, respectively). These genotypes did not confer adverse effects among women who had never smoked; therefore, maternal smoking in combination with maternal AhR, CYP1A1 and GSTM1 genetic polymorphisms may adversely affect infant birth size.

  4. Weight-for-length/height growth curves for children and adolescents in China in comparison with body mass index in prevalence estimates of malnutrition.

    PubMed

    Zong, Xinnan; Li, Hui; Zhang, Yaqin; Wu, Huahong

    2017-05-01

    It is important to update weight-for-length/height growth curves in China and re-examine their performance in screening malnutrition. To develop weight-for-length/height growth curves for Chinese children and adolescents. A total of 94 302 children aged 0-19 years with complete sex, age, weight and length/height data were obtained from two cross-sectional large-scaled national surveys in China. Weight-for-length/height growth curves were constructed using the LMS method before and after average spermarcheal/menarcheal ages, respectively. Screening performance in prevalence estimates of wasting, overweight and obesity was compared between weight-for-height and body mass index (BMI) criteria based on a test population of 21 416 children aged 3-18. The smoothed weight-for-length percentiles and Z-scores growth curves with length 46-110 cm for both sexes and weight-for-height with height 70-180 cm for boys and 70-170 cm for girls were established. The weight-for-height and BMI-for-age had strong correlation in screening wasting, overweight and obesity in each age-sex group. There was no striking difference in prevalence estimates of wasting, overweight and obesity between two indicators except for obesity prevalence at ages 6-11. This set of smoothed weight-for-length/height growth curves may be useful in assessing nutritional status from infants to post-pubertal adolescents.

  5. Comparative morphometry of the antebrachial and crural interosseous membranes: preliminary study for the use of the crural interosseous membrane in the surgical repair of the antebrachial interosseous membrane tears.

    PubMed

    Elamrani, Driss; Aumar, Aurélien; Wavreille, Guillaume; Fontaine, Christian

    2014-05-01

    Traumatic tears of the antebrachial interosseous membrane (AIOM) on its whole length are difficult to treat, particularly in the Essex-Lopresti syndrome. The number of ligamentoplasty techniques described in the literature witnesses the difficulty of its reconstruction and the absence of reliable and satisfying procedure. The aim of this study was to explore a new way of treatment, which consists in replacing the AIOM by the crural interosseous membrane (CIOM), harvested from the same patient. A morphometric study of the AIOM and CIOM has been conducted on both sides of 15 formalin preserved corpses (i.e. 30 AIOM and 30 CIOM). Studied data were: length of forearms and legs, length and width (at different locations) of the membranes, in situ and after harvesting, and orientation of their fibers. The thickness of membrane was also measured but only after harvesting. Concerning the AIOM, the mean length was 13.3 cm in situ and 12.8 cm after harvesting. Its width was maximal at the union of middle and distal thirds with an average value of 1.7 cm in situ and 1.45 cm after harvesting. Mean thickness was 1 mm. Anterior fibers were oblique distally and medially (20.5° ± 0.95°), and posterior fibers were oblique distally and laterally (40° ± 3.4°). Concerning the CIOM, the mean length was 24.75 cm in situ and 23.9 cm after harvesting. Its width was maximal at the union of proximal and middle thirds with an average value of 2.3 cm in situ and 1.85 cm after harvesting. Mean thickness was 0.5 mm. Obliquity of its fibers was reverse of that of the AIOM: the anterior fibers were quite oblique distally and laterally (13° ± 2.6°), and the posterior fibers oblique were oblique distally and medially (24.2° ± 2.48°). From these results, one may conclude that the largest length and width of the CIOM allow its use as substitute for the injured AIOM. The orientation of its fibers should necessitate either its reversal while using the same side or the use of the CIOM of the opposite side; its relative sharpness could signify that its biomechanical properties could be worse. A biomechanical study is necessary to evaluate how this new way of replacing the AIOM could resist to the strains imposed on the forearm.

  6. A Simple Laparoscopic Procedure to Restore a Normal Vaginal Length After Colpohysterectomy With Large Upper Colpectomy for Cervical and/or Vaginal Neoplasia.

    PubMed

    Leblanc, Eric; Bresson, Lucie; Merlot, Benjamin; Puga, Marco; Kridelka, Frederic; Tsunoda, Audrey; Narducci, Fabrice

    2016-01-01

    Colpohysterectomy is sometimes associated with a large upper colpectomy resulting in a shortened vagina, potentially impacting sexual function. We report on a preliminary experience of a laparoscopic colpoplasty to restore a normal vaginal length. Patients with shortened vaginas after a laparoscopic colpohysterectomy were considered for a laparoscopic modified Davydov's procedure to create a new vaginal vault using the peritoneum of the rectum and bladder. From 2010 to 2014, 8 patients were offered this procedure, after informed preoperative consent. Indications were 2 extensive recurrent vaginal intraepithelial neoplasias grade 3 and 6 radical hysterectomies for cervical cancer. Mean vaginal length before surgery was 3.8 cm (standard deviation, 1.6). Median operative time was 50 minutes (range, 45-90). Blood loss was minimal (50-100 mL). No perioperative complications occurred. Median vaginal length at discharge was 11.3 cm (range, 9-13). Sexual intercourse could be resumed around 10 weeks after surgery. At a median follow-up of 33.8 months (range, 2.4-51.3), 6 patients remained sexually active but 2 had stopped. Although this experience is small, this laparoscopic modified Davydov's procedure seems to be an effective procedure, adaptable to each patient's anatomy. If the initial postoperative regular self-dilatation is carefully observed, vaginal patency is durably restored and enables normal sexual function. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  7. Active Plasma Lensing for Relativistic Laser-Plasma-Accelerated Electron Beams

    DOE PAGES

    van Tilborg, J.; Steinke, S.; Geddes, C. G. R.; ...

    2015-10-28

    The compact, tunable, radially symmetric focusing of electrons is critical to laser-plasma accelerator (LPA) applications. Experiments are presented demonstrating the use of a discharge-capillary active plasma lens to focus 100-MeV-level LPA beams. The lens can provide tunable field gradients in excess of 3000 T/m, enabling cm-scale focal lengths for GeV-level beam energies and allowing LPA-based electron beams and light sources to maintain their compact footprint. For a range of lens strengths, excellent agreement with simulation was obtained.

  8. Is short stature associated with short cervical length?

    PubMed

    Gagel, Caroline K; Rafael, Timothy J; Berghella, Vincenzo

    2010-10-01

    We sought to estimate if there is a correlation between maternal height and cervical length in women at high risk for preterm birth. We studied a retrospective cohort of women with singleton gestation and risk factors for preterm birth. Maternal height was categorized as short (<157.5 cm) or not short stature (≥157.5 cm). Cervical length at 14 to 24 weeks was evaluated. Primary outcomes were incidence of initial cervical length <30 mm and incidence of shortest cervical length <25 mm. Four hundred sixteen women met the inclusion criteria. Twenty-two (22.6%) of the short women and 79 (24.5%) of the nonshort women had an initial cervical length <30 mm ( P = 0.81). Twenty-two (23.7%) of the short women and 104 (32.2%) of the nonshort women had a cervical length <25 mm for shortest cervical length measurement ( P = 0.15). In women with singleton gestation and risk factors for preterm birth, no statistically significant relationship exists between maternal height and initial or shortest cervical length. © Thieme Medical Publishers.

  9. The phototoxic effects of fluoranthene on bullfrog tadpoles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, S.E.; Taylor, D.H.; Oris, J.T.

    1995-12-31

    The objective of this study was to determine the phototoxic effects of fluoranthene on bullfrog larvae by examining the relationship between median time to death and fluoranthene concentration and by examining the effects of short-term sublethal fluoranthene exposure on behavior and body condition. To determine the relationship between median time to death and fluoranthene concentration, tadpoles were exposed to either 0, 60, 80, 100 or 120 mg fluoranthene/L, and monitored for 144h under SUVR (40--50 mW/cm{sup 2} UVA, 4--6 mW/cm{sup 2} UVB). To examine the effects of fluoranthene on behavior and body condition, 20 tadpoles were exposed to either 0,more » 10, or 40 mg fluoranthene/L with simulated SUVR for either 48 or 96 h. At either 48 or 96 h ten individuals were removed and their locomotor activity was monitored and the body length and mass determined. Median time to death decreased with increased fluoranthene concentration and appears to do so in a linear fashion. Body condition was determined using a ratio index (mass/length{sup 3}) and a residual index was determined using the residuals of a regression of body length and body mass. Both exposure time and concentration affected both condition indices. Body burden was significantly affected at 10 mg fluoranthene/L. Exposure to fluoranthene for 48 h caused no significant effect on locomotor activity. However, at 96 h hyperactivity was noted in the highest fluoranthene exposure concentration. These results indicate that exposure to fluoranthene under environmentally realistic conditions can cause both lethal and sublethal effects on amphibian larvae.« less

  10. Impact of direct substitution of arm span length for current standing height in elderly COPD.

    PubMed

    Pothirat, Chaicharn; Chaiwong, Warawut; Phetsuk, Nittaya

    2015-01-01

    Arm span length is related to standing height and has been studied as a substitute for current standing height for predicting lung function parameters. However, it has never been studied in elderly COPD patients. To evaluate the accuracy of substituting arm span length for current standing height in the evaluation of pulmonary function parameters and severity classification in elderly Thai COPD patients. Current standing height and arm span length were measured in COPD patients aged >60 years. Postbronchodilator spirometric parameters, forced vital capacity (FVC), forced expiratory volume in first second (FEV1), and ratio of FEV1/FVC (FEV1%), were used to classify disease severity according to global initiative for chronic obstructive lung disease criteria. Predicted values for each parameter were also calculated separately utilizing current standing height or arm span length measurements. Student's t-tests and chi-squared tests were used to compare differences between the groups. Statistical significance was set at P<0.05. A total of 106 COPD patients with a mean age of 72.1±7.8 years, mean body mass index of 20.6±3.8 kg/m(2), and mean standing height of 156.4±8.3 cm were enrolled. The mean arm span length exceeded mean standing height by 7.7±4.6 cm (164.0±9.0 vs 156.4±8.3 cm, P<0.001), at a ratio of 1.05±0.03. Percentages of both predicted FVC and FEV1 values based on arm span length were significantly lower than those using current standing height (76.6±25.4 vs 61.6±16.8, P<0.001 and 50.8±25.4 vs 41.1±15.3, P<0.001). Disease severity increased in 39.6% (42/106) of subjects using arm span length over current standing height for predicted lung function. Direct substitution of arm span length for current standing height in elderly Thai COPD patients should not be recommended in cases where arm span length exceeds standing height by more than 4 cm.

  11. Measuring newborn foot length to identify small babies in need of extra care: a cross sectional hospital based study with community follow-up in Tanzania.

    PubMed

    Marchant, Tanya; Jaribu, Jennie; Penfold, Suzanne; Tanner, Marcel; Armstrong Schellenberg, Joanna

    2010-10-19

    Neonatal mortality because of low birth weight or prematurity remains high in many developing country settings. This research aimed to estimate the sensitivity and specificity, and the positive and negative predictive values of newborn foot length to identify babies who are low birth weight or premature and in need of extra care in a rural African setting. A cross-sectional study of newborn babies in hospital, with community follow-up on the fifth day of life, was carried out between 13 July and 16 October 2009 in southern Tanzania. Foot length, birth weight and gestational age were estimated on the first day and foot length remeasured on the fifth day of life. In hospital 529 babies were recruited and measured within 24 hours of birth, 183 of whom were also followed-up at home on the fifth day. Day one foot length <7 cm at birth was 75% sensitive (95%CI 36-100) and 99% specific (95%CI 97-99) to identify very small babies (birth weight <1500 grams); foot length <8 cm had sensitivity and specificity of 87% (95%CI 79-94) and 60% (95%CI 55-64) to identify those with low birth weight (<2500 grams), and 93% (95%CI 82-99) and 58% (95%CI 53-62) to identify those born premature (<37 weeks). Mean foot length on the first day was 7.8 cm (standard deviation 0.47); the mean difference between first and fifth day foot lengths was 0.1 cm (standard deviation 0.3): foot length measured on or before the fifth day of life identified more than three-quarters of babies who were born low birth weight. Measurement of newborn foot length for home births in resource poor settings has the potential to be used by birth attendants, community volunteers or parents as a screening tool to identify low birth weight or premature newborns in order that they can receive targeted interventions for improved survival.

  12. [Effects of tillage practices on root spatial distribution and yield of spring wheat and pea in the dry land farming areas of central Gansu, China].

    PubMed

    Zhang, Ming Jun; Li, Ling Ling; Xie, Jun Hong; Peng, Zheng Kai; Ren, Jin Hu

    2017-12-01

    A field experiment was conducted to explore the mechanism of cultivation measures in affecting crop yield by investigating root distribution in spring wheat-pea rotation based on a long-term conservation tillage practices in a farming region of Gansu. The results showed that with the develo-pment of growth period, the total root length, root surface area of spring wheat and pea showed a consistent trend of increase after initial decrease and reached the maximum at flowering stage. Higher root distribution was found in the 0-10 cm soil layer at seedling and 10-30 cm soil layer at flowering and maturity stages in spring wheat, while in the field pea, higher root distribution was found in the 0-10 cm soil layer at seedling and maturity, and in the 10-30 cm soil layer at flowering stages. No tillage with straw mulching and plastic mulching increased the root length and root surface area. Compared with conventional tillage in spring wheat and field pea, root length increased by 35.9% to 92.6%, and root surface area increased by 43.2% to 162.4%, respectively. No tillage with straw mulching and plastic mulching optimized spring wheat and pea root system distribution, compared with conventional tillage, increased spring wheat and field pea root length and root surface area ratio at 0-10 cm depths at the seedling stage, the root distribution at deeper depths increased significantly at flowering and maturity stages, and no tillage with straw mulching increased root length and root surface area ratio by 3.3% and 9.7% respectively, in 30-80 cm soil layer at the flowering stage. The total root length, root surface area and yield had significantly positive correlation for spring wheat in each growth period, and the total root length and pea yield also had significant positive correlation. No tillage with straw mulching and plastic mulching boosted yield of spring wheat and pea by 23.4%-38.7% compared with the conventional tillage, and the water use efficiency was increased by 13.7%-28.5%. It was concluded that no-till farming and straw mulching (plastic) could increase crop root length and root surface area, optimize the spatial distribution of roots in the soil, enhance crop root layer absorption ability, so as to improve crop yield and water utilization.

  13. Reconstruction of juxta-articular huge defects of distal femur with vascularized fibular bone graft and Ilizarov's distraction osteogenesis.

    PubMed

    Lai, Davy; Chen, Chuan-Mu; Chiu, Fang-Yao; Chang, Ming-Chau; Chen, Tain-Hsiung

    2007-01-01

    We evaluate the effect of reconstructing huge defects (mean, 15.8 cm) of the distal femur with Ilizarov's distraction osteogenesis and free twin-barreled vascularized fibular bone graft (TVFG). We retrospectively reviewed a consecutive series of five patients who had cases of distal femoral fractures with huge defects and infection that were treated by the Ilizarov's distraction osteogenesis. After radical debridement, two of the five cases had free TVFG and monolocal distraction osteogenesis, and another two cases had multilocal distraction osteogenesis with knee fusion because of loss of the joint congruity. The other case with floating knee injury had bilocal distraction osteogenesis and a preserved knee joint. The mean defect of distal femur was 15.8 cm (range, 14-18 cm) in length. The mean length of distraction osteogenesis by Ilizarov's apparatus was 8.2 cm. The mean length of TVFG was 8 cm. The average duration from application of Ilizarov's apparatus to achievement of bony union was 10.2 months (range, 8-13 months). At the end of the follow-up, ranges of motion of three knees were 0 to 45 degrees, 0 to 60 degrees, and 0 to 90 degrees. Two cases had knee arthrodesis with bony fusion because of loss of the joint congruity. There were no leg length discrepancies in all five patients. In addition, three patients had pin tract infections and one case had a 10 degree varus deformity of the femur. Juxta-articular huge defect (>10 cm) of distal femur remains a challenge to orthopedic surgeons. Ilizarov's technique provides the capability to maintain stability, eradicate infection, restore leg length, and to perform adjuvant reconstructive procedure easily. In this study, we found that combining Ilizarov's distraction osteogenesis with TVFG results in improved patient outcome for patients with injuries such as supracondylar or intercondylar infected fractures or nonunion of distal femur with huge bone defect.

  14. Transoral robotic resection of a large schwannoma in the retropharyngeal space.

    PubMed

    Gungadeen, A; Lisseter, R; Manickavasagam, J; Paleri, V

    2016-04-01

    External approaches have been traditionally used for the complete excision of large retropharyngeal space lesions. This paper describes a case of a large schwannoma of the retropharyngeal space excised transorally with the use of a robotic system. This lesion measured 2.7 × 1.2 cm in axial dimensions and over 5.8 cm in craniocaudal length. The lesion was delivered en bloc with an intact capsule. No peri- or post-operative complications were encountered. The procedure allowed quick resumption of an oral diet and a return to normal activity for the patient. This is, to our knowledge, the first report of this technique used in the excision of a large retropharyngeal space mass.

  15. Some observations on the biology of two rarely seen deep-sea chimaerids, Chimaera carophila and Hydrolagus homonycteris.

    PubMed

    Finucci, B; Stevens, D W; Jones, E G; Dunn, M R

    2017-05-01

    Chimaera carophila (n = 45) and Hydrolagus homonycteris (n = 11), two deep-sea chimaerids rarely caught in the waters off New Zealand, were collected from research trawl catches and commercial fishery catches around New Zealand at depths between 400 and 1300 m, between 2014 and 2016. Additional preserved specimens of both species (n = 58) from museum collections were analysed for size, sex and maturity. External assessment of male claspers and a combination of internal assessments of female gonad mass and oviducal gland width, were used to determine maturity. For both species, length at first maturity was 0·70-0·82 of their maximum observed chimaera length (L C ), with females maturing at a larger size. Length at maturity for C. carophila (L C range: 28·7-103·9 cm) was estimated at 72·5 cm L C for males (n = 163) and 82·5 L C for females (n = 58). In H. homonycteris, length at maturity (length range: 78·6-99·8 cm L C ) was estimated at 79·1 cm L C for males (n = 51) and 80·1 cm L C for females (n = 17). Ovarian fecundity was up to 31 for C. carophila and sperm storage was confirmed in the oviducal gland of this species. Both species preyed on benthic invertebrates. Some C. carophila and H. homonycteris inhabit depths beyond most current fisheries, but both species appear to be relatively rare and have reproductive parameters characteristic of low productivity, which may make these species vulnerable to population decline if mortality was to increase in the future. © 2017 The Fisheries Society of the British Isles.

  16. The deep layer of the tractus iliotibialis and its relevance when using the direct anterior approach in total hip arthroplasty: a cadaver study.

    PubMed

    Putzer, David; Haselbacher, Matthias; Hörmann, Romed; Klima, Günter; Nogler, Michael

    2017-12-01

    Surgical approaches through smaller incisions reveal less of the underlying anatomy, and therefore, detailed knowledge of the local anatomy and its variations is important in minimally invasive surgery. The aim of this study was to determine the location, extension, and histomorphology of the deep layer of the iliotibial band during minimally invasive hip surgery using the direct anterior approach (DAA). The morphology of the iliotibial tract was determined in this cadaver study on 40 hips with reference to the anterior superior iliac spine and the tibia. The deep layer of the tractus iliotibialis was exposed up to the hip-joint capsule and length and width measurements taken. Sections of the profound iliotibial tract were removed from the hips and the thickness of the sections was determined microscopically after staining. The superficial tractus iliotibialis had a length of 50.1 (SD 3.8) cm, while tensor fasciae latae total length was 18 (SD 2) cm [unattached 15 (SD 2.5) cm]. Length and width of the deep layer of the tractus iliotibialis were 10.4 (SD 1.3) × 3.3 (SD 0.6) cm. The deep iliotibial band always extended from the distal part of the tensor fascia latae (TFL) muscle to the lateral part of the hip capsule (mean maximum thickness 584 μm). Tractus iliotibialis deep layer morphology did not correlate to other measurements taken (body length, thigh length, and TFL length). The length of the deep layer is dependent on the TFL, since the profound part of the iliotibial band reaches from the TFL to the hip-joint capsule. The deep layer covers the hip-joint capsule, rectus, and lateral vastus muscles in the DAA interval. To access the precapsular fat pad and the hip-joint capsule, the deep layer has to be split in all approaches that use the direct anterior interval.

  17. Study of the amplified spontaneous emission spectral width and gain coefficient for a KrF laser in unsaturated and saturated conditions

    NASA Astrophysics Data System (ADS)

    Hariri, A.; Sarikhani, S.

    2014-01-01

    On the basis of a model of a geometrically dependent gain coefficient, the amplified spontaneous emission (ASE) spectral width was calculated analytically for the nearly resonant transition of ν ˜ ν0, and also numerically for a wide range of transition frequencies. For this purpose, the intensity rate equation was used under unsaturated and saturated conditions. For verifying the proposed model, reported measurements of the ASE energy versus the excitation length for a KrF laser were used. For the excitation length of l = 84 cm corresponding to single-path propagation, the ASE spectral width for the homogeneously broadened transition was calculated to be 6.28 Å, to be compared with the measured 4.1 Å spectral width reported for a KrF oscillator utilizing a two-mirror resonator. With the gain parameters obtained from the ASE energy measurements, the unsaturated and saturated gain coefficients for l = 84 cm were calculated to be 0.042 cm-1 and 0.014 cm-1, respectively. These values of the gain coefficient are comparable to but slightly lower than the measured gain coefficient for laser systems of 80-100 cm excitation lengths reported from different laboratories.

  18. SU-E-J-49: Distal Edge Activity Fall Off Of Proton Therapy Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elmekawy, A; Ewell, L; Butuceanu, C

    2014-06-01

    Purpose: To characterize and quantify the distal edge activity fall off, created in a phantom by a proton therapy beam Method and Materials: A 30x30x10cm polymethylmethacrylate phantom was irradiated with a proton therapy beam using different ranges and beams. The irradiation volume is approximated by a right circular cylinder of diameter 7.6cm and varying lengths. After irradiation, the phantom was scanned via a Philips Gemini Big Bore™ PET-CT for isotope activation. Varian Eclipse™ treatment planning system as well as ImageJ™ were used to analyze the resulting PET and CT scans. The region of activity within the phantom was longitudinally measuredmore » as a function of PET slice number. Dose estimations were made via Monte Carlo (GATE) simulation. Results: For both the spread out Bragg peak (SOBP) and the mono-energetic pristine Bragg peak proton beams, the proximal activation rise was steep: average slope −0.735 (average intensity/slice number) ± 0.091 (standard deviation) for the pristine beams and −1.149 ± 0.117 for the SOBP beams. In contrast, the distal fall offs were dissimilar. The distal fall off in activity for the pristine beams was fit well by a linear curve: R{sup 2} (Pierson Product) was 0.9968, 0.9955 and 0.9909 for the 13.5, 17.0 and 21.0cm range beams respectively. The good fit allows for a slope comparison between the different ranges. The slope varied as a function of range from 1.021 for the 13.5cm beam to 0.8407 (average intensity/slice number) for the 21.0cm beam. This dependence can be characterized: −0.0234(average intensity/slice number/cm range). For the SOBP beams, the slopes were significantly less and were also less linear: average slope 0.2628 ± 0.0474, average R{sup 2}=0.9236. Conclusion: The distal activation fall off edge for pristine proton beams was linear and steep. The corresponding quantities for SOBP beams were shallower and less linear. Philips has provided support for this work.« less

  19. Laser Ablation Mass Spectrometer (LAMS) as a Standoff Analyzer in Space Missions for Airless Bodies

    NASA Technical Reports Server (NTRS)

    Li, X.; Brinckerhoff, W. B.; Managadze, G. G.; Pugel, D. E.; Corrigan, C. M.; Doty, J. H.

    2012-01-01

    A laser ablation mass spectrometer (LAMS) based on a time-of-flight (TOF) analyzer with adjustable drift length is proposed as a standoff elemental composition sensor for space missions to airless bodies. It is found that the use of a retarding potential analyzer in combination with a two-stage reflectron enables LAMS to be operated at variable drift length. For field-free drift lengths between 33 cm to 100 cm, at least unit mass resolution can be maintained solely by adjustment of internal voltages, and without resorting to drastic reductions in sensitivity. Therefore, LAMS should be able to be mounted on a robotic arm and analyze samples at standoff distances of up to several tens of cm, permitting high operational flexibility and wide area coverage of heterogeneous regolith on airless bodies.

  20. Design study of imaging techniques for the Starprobe mission

    NASA Technical Reports Server (NTRS)

    Bottema, M.

    1981-01-01

    A 10 cm aperture, off-axis aplanatic gregorian telescope is investigated as a candidate instrument for imaging from Starprobe in the 115 nm to 900 nm wavelength range. Focal lengths of 300 cm (f/30) and 150 cm (f/15) are compared in terms of optical performance, compatibility with the Starprobe spacecraft and response to the thermal environment in a 20-hour time interval, centered on perihelion. Ultraviolet/visible imaging from Starprobe concluded should be technically feasible. A 10 cm aperture telescope with focal length close to 300 cm is recommended for further study. This instrument should be capable of a detector-limited angular resoluton of about 2 arc sec. The estimated overall dimensions should not exceed 105 cm by 40 cm by 25 cm and its mass be less than 28 kg. The recommended concept assumes solid blank ULE mirrors, a graphite-epoxy optical bench, and an aluminum thermal enclosure, covered with multilayer insulation. These materials must be carefully selected to minimize the risk of UV photopolymerization of contaminants at the mirror surfaces during observtions.

  1. On Short-Time Estimation of Vocal Tract Length from Formant Frequencies

    PubMed Central

    Lammert, Adam C.; Narayanan, Shrikanth S.

    2015-01-01

    Vocal tract length is highly variable across speakers and determines many aspects of the acoustic speech signal, making it an essential parameter to consider for explaining behavioral variability. A method for accurate estimation of vocal tract length from formant frequencies would afford normalization of interspeaker variability and facilitate acoustic comparisons across speakers. A framework for considering estimation methods is developed from the basic principles of vocal tract acoustics, and an estimation method is proposed that follows naturally from this framework. The proposed method is evaluated using acoustic characteristics of simulated vocal tracts ranging from 14 to 19 cm in length, as well as real-time magnetic resonance imaging data with synchronous audio from five speakers whose vocal tracts range from 14.5 to 18.0 cm in length. Evaluations show improvements in accuracy over previously proposed methods, with 0.631 and 1.277 cm root mean square error on simulated and human speech data, respectively. Empirical results show that the effectiveness of the proposed method is based on emphasizing higher formant frequencies, which seem less affected by speech articulation. Theoretical predictions of formant sensitivity reinforce this empirical finding. Moreover, theoretical insights are explained regarding the reason for differences in formant sensitivity. PMID:26177102

  2. Effect of 1.5 MeV electron irradiation on β-Ga2O3 carrier lifetime and diffusion length

    NASA Astrophysics Data System (ADS)

    Lee, Jonathan; Flitsiyan, Elena; Chernyak, Leonid; Yang, Jiancheng; Ren, Fan; Pearton, Stephen J.; Meyler, Boris; Salzman, Y. Joseph

    2018-02-01

    The influence of 1.5 MeV electron irradiation on minority transport properties of Si doped β-Ga2O3 vertical Schottky rectifiers was observed for fluences up to 1.43 × 1016 cm-2. The Electron Beam-Induced Current technique was used to determine the minority hole diffusion length as a function of temperature for each irradiation dose. This revealed activation energies related to shallow donors at 40.9 meV and radiation-induced defects with energies at 18.1 and 13.6 meV. Time-resolved cathodoluminescence measurements showed an ultrafast 210 ps decay lifetime and reduction in carrier lifetime with increased irradiation.

  3. Comparison of the effect of the rotation palatoplasty and V-Y pushback palatoplasty techniques on palate elongation with magnetic resonance imaging.

    PubMed

    Isik, D; Bora, A; Yuce, S; Davran, R; Kocak, O F; Canbaz, Y; Avcu, S; Atik, B

    2015-06-01

    Most surgical techniques used in cleft palate repair require the extension of the palate to the pharynx. However, no adequate information exists regarding the extent to which this elongation obtained during operation continues in late postoperative period. In this study, we compared and measured palate elongation in patients with a cleft palate who underwent a V-Y pushback or rotation palatoplasty, by means of magnetic resonance images obtained before and 1 year after surgery. The hard palate, soft palate, and total palate lengths were measured for all of the patients, and the velopharyngeal opening area width was calculated. In patients who underwent the V-Y pushback technique (n=13), the total palate and soft palate lengths were shortened by an average of 0.10 and 0.14cm after surgery, respectively. However, the hard palate length was elongated by an average of 0.13cm. In the rotation palatoplasty group (n=13), the total palate, hard palate, and soft palate lengths were elongated by 0.57, 0.10, and 0.49cm, respectively. The velopharyngeal opening was narrowed by 0.06cm(2) using the V-Y pushback technique and by 0.29cm(2) using the rotational palatoplasty. This study demonstrated that the palate does not elongate during the V-Y pushback technique, as expected. However, rotational palatoplasty elongates the soft palate. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. The effect of incremental distal gastric myotomy lengths on EGJ distensibility during POEM for achalasia

    PubMed Central

    Teitelbaum, Ezra N.; Sternbach, Joel M.; Khoury, Rym El; Soper, Nathaniel J.; Pandolfino, John E.; Kahrilas, Peter J.; Lin, Zhiyue; Hungness, Eric S.

    2015-01-01

    Background During peroral esophageal myotomy (POEM) for the treatment of achalasia, the optimal distal gastric myotomy length is unknown. In this study we used a functional lumen imaging probe (FLIP) to intraoperatively measure the effect of variable distal myotomy lengths on esophagogastric junction (EGJ) distensibility. Methods EGJ distensibility index (DI) (minimum cross-sectional area divided by intra-bag pressure) was measured with FLIP after each operative step. Each patient's myotomy was performed in four increments from proximal to distal: 1) an esophageal myotomy (from 6cm proximal to the EGJ, to 1cm proximal to it), 2) a myotomy ablating the lower esophageal sphincter (LES) complex (from 1cm proximal to the EGJ, to 1cm distal to it), 3) an initial gastric extension (from 1cm distal to the EGJ, to 2cm distal), and 4) a final gastric extension (from 2cm distal to the EGJ, to 3cm distal). Results Measurements were performed in 16 achalasia patients during POEM. POEM resulted in an overall increase in DI (pre 1.2 vs. post 7.2 mm2/mmHg, p<.001). Initial creation of the submucosal tunnel resulted in a 3-fold increase in DI (1.2 vs. 3.6 mm2/mmHg, p<.001). When the myotomy was then performed in a stepwise fashion from proximal to distal, the initial esophageal myotomy component had no effect on DI. Subsequent myotomy extension across the LES complex resulted in an increase in DI, as did the initial gastric myotomy extension (to 2cm distal to the EGJ). The final gastric myotomy extension (to 3cm distal) had no further effect. Conclusions During POEM, creation of the submucosal tunnel prior to myotomy resulted in a marked improvement in EGJ physiology. Myotomy extension across the LES complex and to 2cm onto the gastric wall resulted in normalization of EGJ distensibility, whereas subsequent extension to 3cm distal to the EGJ did not increase compliance further. PMID:26092005

  5. Growth to Age 18 Months Following Prenatal Supplementation with Docosahexaenoic Acid Differs by Maternal Gravidity in Mexico1234

    PubMed Central

    Stein, Aryeh D; Wang, Meng; Martorell, Reynaldo; Neufeld, Lynnette M.; Flores-Ayala, Rafael; Rivera, Juan A.; Ramakrishnan, Usha

    2011-01-01

    Little is known about the long-term effects of DHA intake during pregnancy. Offspring of primagravid Mexican women who received 400 mg/d DHA from wk 20 of gestation through delivery were heavier and had larger head circumferences at birth than children whose mothers received placebo; no effect was observed in offspring of multigravidae. We have followed these children (n = 739; 76% of the birth cohort), measuring length, weight, and head circumference at 1, 3, 6, 9, 12, and 18 mo. At 18 mo, intent-to-treat differences between placebo and DHA, adjusted for maternal height and child sex and age at measurement, were: length, −0.21 cm (95% CI = −0.58, 0.15); weight, −0.03 kg (95% CI =−0.19, 0.13); and head circumference, 0.02 cm (95% CI = −0.18, 0.21) (all P > 0.05). There was heterogeneity of associations by maternal gravidity for weight (P < 0.08), length (P < 0.02), and head circumference (P < 0.05). Among offspring of primagravid women, length at 18 mo was increased by 0.72 cm (95% CI = 0.11, 1.33) following DHA supplementation, representing 0.26 length-for-age Z-score units; among offspring of multigravidae, the estimate was −0.13 cm (95% CI = −0.59, 0.32) (P > 0.5). Maternal DHA supplementation during the second half of gestation may enhance growth through 18 mo of children born to primagravid women. PMID:21178082

  6. Growth to age 18 months following prenatal supplementation with docosahexaenoic acid differs by maternal gravidity in Mexico.

    PubMed

    Stein, Aryeh D; Wang, Meng; Martorell, Reynaldo; Neufeld, Lynnette M; Flores-Ayala, Rafael; Rivera, Juan A; Ramakrishnan, Usha

    2011-02-01

    Little is known about the long-term effects of DHA intake during pregnancy. Offspring of primagravid Mexican women who received 400 mg/d DHA from wk 20 of gestation through delivery were heavier and had larger head circumferences at birth than children whose mothers received placebo; no effect was observed in offspring of multigravidae. We have followed these children (n = 739; 76% of the birth cohort), measuring length, weight, and head circumference at 1, 3, 6, 9, 12, and 18 mo. At 18 mo, intent-to-treat differences between placebo and DHA, adjusted for maternal height and child sex and age at measurement, were: length, -0.21 cm (95% CI = -0.58, 0.15); weight, -0.03 kg (95% CI =-0.19, 0.13); and head circumference, 0.02 cm (95% CI = -0.18, 0.21) (all P > 0.05). There was heterogeneity of associations by maternal gravidity for weight (P < 0.08), length (P < 0.02), and head circumference (P < 0.05). Among offspring of primagravid women, length at 18 mo was increased by 0.72 cm (95% CI = 0.11, 1.33) following DHA supplementation, representing 0.26 length-for-age Z-score units; among offspring of multigravidae, the estimate was -0.13 cm (95% CI = -0.59, 0.32) (P > 0.5). Maternal DHA supplementation during the second half of gestation may enhance growth through 18 mo of children born to primagravid women.

  7. Optimization of the artificial urinary sphincter: modelling and experimental validation

    NASA Astrophysics Data System (ADS)

    Marti, Florian; Leippold, Thomas; John, Hubert; Blunschi, Nadine; Müller, Bert

    2006-03-01

    The artificial urinary sphincter should be long enough to prevent strangulation effects of the urethral tissue and short enough to avoid the improper dissection of the surrounding tissue. To optimize the sphincter length, the empirical three-parameter urethra compression model is proposed based on the mechanical properties of the urethra: wall pressure, tissue response rim force and sphincter periphery length. In vitro studies using explanted animal or human urethras and different artificial sphincters demonstrate its applicability. The pressure of the sphincter to close the urethra is shown to be a linear function of the bladder pressure. The force to close the urethra depends on the sphincter length linearly. Human urethras display the same dependences as the urethras of pig, dog, sheep and calf. Quantitatively, however, sow urethras resemble best the human ones. For the human urethras, the mean wall pressure corresponds to (-12.6 ± 0.9) cmH2O and (-8.7 ± 1.1) cmH2O, the rim length to (3.0 ± 0.3) mm and (5.1 ± 0.3) mm and the rim force to (60 ± 20) mN and (100 ± 20) mN for urethra opening and closing, respectively. Assuming an intravesical pressure of 40 cmH2O, and an external pressure on the urethra of 60 cmH2O, the model leads to the optimized sphincter length of (17.3 ± 3.8) mm.

  8. Performance of juvenile steelhead trout (Oncorhynchus mykiss) produced from untreated and cryopreserved milt

    USGS Publications Warehouse

    Hayes, Michael C.; Rubin, Stephen P.; Hensleigh, Jay E.; Reisenbichler, Reginald R.; Wetzel, Lisa A.

    2005-01-01

    Despite the expanding use of milt cryopreservation in aquaculture, the performance of fish produced from this technique has not been fully explored beyond initial rearing stages. We compared the performance of juvenile steelhead Oncorhynchus mykiss produced from untreated (UM) and cryopreserved milt (CM) and reared for 4–9 months. For the 1996 brood, CM alevins were heavier (∼ 1.7%, P < 0.01) than UM alevins and length was influenced by a significant milt-by-family interaction (P < 0.03) suggesting a greater treatment effect for some families. No significant differences were found in length or weight (P > 0.05) for 1997 brood alevins and percent yolk was similar for both broods (P > 0.34). In growth and survival experiment I (GSE-I, 1996), UM and CM juveniles reared in separate tanks and fed to satiation (130 days) showed no significant differences in survival, length or weight (P > 0.05) between milt groups. In contrast, for UM and CM siblings reared in the same tank for 210 days on a low food ration (GSE-II), survival was similar (P > 0.05), but length (UM 4% > CM, P < 0.05) and possibly weight (UM 15% > CM, P = 0.08), were influenced by cryopreservation. Fish from the 1997 brood (GSE-III) were reared for 313 days in a repeat of GSE-II and no differences were found in survival (P = 0.47), length (P = 0.75) or weight (P = 0.76) suggesting considerable heterogeneity between broods. Performance of the 1996 brood was also tested for response to stress and a disease challenge. Cortisol responses of juveniles exposed to acute stress were not significantly different (P = 0.19), but mean cortisol was consistently and significantly greater (P < 0.01) for CM than UM fish exposed to a 48-h stress (increased density). After exposure to three dosages of the bacteria, Listonella anguillarum, we found similar mortality proportions (P = 0.72) for UM and CM fish. Variable juvenile performance for the parameters tested indicated significant differences among broods and families and suggests a cautionary approach to the widespread use of cryopreservation for steelhead.

  9. A morphological and morphometric study of proximal and distal ends of dry radii with its clinical implications.

    PubMed

    Gupta, Chandni; Kalthur, Sneha Guruprasad; Malsawmzuali, J C; D'souza, Antony Sylvan

    2015-01-01

    Knowledge of the size and shape of radial head is essential for construction of radial head prosthesis. Further, the measurements of bicipital tuberosity and its angular relationship to radial head are significant in surgical techniques, like in the reconstruction of biceps tendon. Even the morphometry of the distal radius is significant in numerous clinical orthopedic situations such as reduction of distal radius fractures and in the design of distal radius prosthesis. So, the aim of the study was to determine the morphometric parameters of proximal and distal radius in dry adult Indian radius. Fifty intact adult Indian radius (right = 23, left = 27) were chosen, and the various parameters of proximal and distal ends of radius were studied. Student's t-test was done to correlate all these parameters on the right and left sides. The mean length of radius, height of head at medial and lateral ends, head anteroposterior and transverse diameter, head thickness at ventral, dorsal, and lateral ends were 23.5, 0.90, 0.75, 1.91, 1.85, 0.42, 0.32, and 0.30 cm, respectively. The mean depth of articular facet, length of neck, proximal and distal neck diameter, width and length of bicipital tuberosity, and radial circumference at bicipital tuberosity were 0.19, 1.19, 1.36, 1.31, 1.23, 1.97, and 4.54 cm, respectively. The mean length of styloid process, oblique and transverse width of lower end, anteroposterior diameter of lower end, and angle of radial inclination were 0.98cm, 2. 81cm, 2.59cm, 1.86cm, and 25.05°, respectively. This study will be useful for orthopedic surgeons in making prosthesis for the proximal and distal ends of radius.

  10. SU-C-16A-04: Dosimetric Validation of a Partially-Shielded Gd-153 Brachytherapy Concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, X; Adams, Q; Flynn, R

    Purpose: To demonstrate by measurement that using partially shielded Gd-153 sources for rotating-shield brachytherapy (RSBT) is feasible. RSBT is a potentially superior alternative to conventional high-dose-rate brachytherapy and provides the opportunity to dramatically improve tumor dose conformity for the treatment of, for example, prostate cancer. Methods: A custom-built, stainless steel encapsulated 150 mCi Gd-153 capsule with an outer length of 12.8 mm, outer diameter of 2.10 mm, active length of 9.98 mm, and active diameter of 1.53 mm was used. A partially shielded catheter was constructed with a 500 μm platinum shield and a 500 μm aluminum emission window, bothmore » with 180° azimuthal coverage. An acrylic phantom was constructed to measure the dose distributions from the shielded catheter in the transverse plane using Gafchromic EBT3 films. Film calibration curves were generated from 50, 70, and 100 kVp x-ray beams with NIST-traceable air kerma values to account for energy variation. Results: The transmission ratios of platinum to aluminum shielding at 1 cm off-axis are 7.5% and 7.6% for Monte Carlo (MCNP5) predicted and experimental results, respectively. The predicted/measured relative dose rates at 1 cm, 2 cm and 3 cm off-axis through the Al window were 100%/92.9%, 28.6%/27.0% and 13.8%/12.7%, respectively. Through the Pt shield, the predicted/measured relative dose rates were 7.5%/7.1%, 3.8%/3.0% and 2.4%/1.7%, respectively. Conclusion: Using partially-shielded Gd-153 sources for RSBT is a promising approach to improving brachytherapy dose distributions. The next step in making Gd-153 based RSBT a reality is developing a Gd-153 source that is small enough such that the source, shield, and catheter all fit within a 16 gauge needle, which has a 1.65 mm diameter. University of Iowa Research Foundation.« less

  11. Flow rate of some pharmaceutical diluents through die-orifices relevant to mini-tableting.

    PubMed

    Kachrimanis, K; Petrides, M; Malamataris, S

    2005-10-13

    The effects of cylindrical orifice length and diameter on the flow rate of three commonly used pharmaceutical direct compression diluents (lactose, dibasic calcium phosphate dihydrate and pregelatinised starch) were investigated, besides the powder particle characteristics (particle size, aspect ratio, roundness and convexity) and the packing properties (true, bulk and tapped density). Flow rate was determined for three different sieve fractions through a series of miniature tableting dies of different orifice diameter (0.4, 0.3 and 0.2 cm) and thickness (1.5, 1.0 and 0.5 cm). It was found that flow rate decreased with the increase of the orifice length for the small diameter (0.2 cm) but for the large diameter (0.4 cm) was increased with the orifice length (die thickness). Flow rate changes with the orifice length are attributed to the flow regime (transitional arch formation) and possible alterations in the position of the free flowing zone caused by pressure gradients arising from the flow of self-entrained air, both above the entrance in the die orifice and across it. Modelling by the conventional Jones-Pilpel non-linear equation and by two machine learning algorithms (lazy learning, LL, and feed-forward back-propagation, FBP) was applied and predictive performance of the fitted models was compared. It was found that both FBP and LL algorithms have significantly higher predictive performance than the Jones-Pilpel non-linear equation, because they account both dimensions of the cylindrical die opening (diameter and length). The automatic relevance determination for FBP revealed that orifice length is the third most influential variable after the orifice diameter and particle size, followed by the bulk density, the difference between bulk and tapped densities and the particle convexity.

  12. Impact of Preoperative Patient Characteristics on Posturethroplasty Recurrence: The Significance of Stricture Length and Prior Treatments

    PubMed Central

    Bello, Jibril Oyekunle

    2016-01-01

    Introduction: Urethral strictures are common in urologic practice of Sub-Saharan Africa including Nigeria. We determine the rate of stricture recurrence following urethroplasty for anterior urethral strictures and evaluate preoperative variables that predict of stricture recurrence in our practice. Subjects and Methods: Thirty-six men who had urethroplasty for proven anterior urethral stricture disease between February 2012 and January 2015 were retrospectively analyzed. Preoperative factors including age, socioeconomic factors, comorbidities, etiology of strictures, stricture location, stricture length, periurethral spongiofibrosis, and prior stricture treatments were assessed for independent predictors of stricture recurrence. Results: The median age was 49.5 years (range 21-90), median stricture length was 4 cm (range 1-18 cm) and the overall recurrence rate was 27.8%. Postinfectious strictures, pan urethral strictures or multiple strictures involving the penile and bulbar urethra were more common. Most patients had penile circular fasciocutaneous flap urethroplasty. Following univariate analysis of potential preoperative predictors of stricture recurrence, stricture length, and prior treatments with dilations or urethrotomies were found to be significantly associated with stricture recurrence. On multivariate analysis, they both remained statistically significant. Patients who had prior treatments had greater odds of having a recurrent stricture (odds ratio 18, 95% confidence interval [CI] 1.4–224.3). Stricture length was dichotomized based on receiver operating characteristic (ROC) analysis, and strictures of length ≥5 cm had significantly greater recurrence (area under ROC curve of 0.825, 95% CI 0.690–0.960, P = 0.032). Conclusion: Patients who had prior dilatations or urethrotomies and those with long strictures particularly strictures ≥5 cm have significantly greater odds of developing a recurrence following urethroplasty in Nigerian urology practice. PMID:27843271

  13. An Annotated Bibliography Of U.S. Army Natick Anthropology (1947-1991).

    DTIC Science & Technology

    1991-08-01

    designers of lasts and shoes for the Army. In order to provide greater detail and also more directly applicable information, ari intensive analysis of the...individual simultaneous computations. These five measuremrnts are: length of cranium 4 cm above Na-S, sinus breadth, total facial height, bigonial and...implications of using the Army’s personal equipment are examined in light of the present and projected demographic ccupsition of the Army active duty

  14. Neo-phalloplasty with re-innervated latissimus dorsi free flap: a functional study of a novel technique.

    PubMed

    Ranno, R; Veselý, J; Hýza, P; Stupka, I; Justan, I; Dvorák, Z; Monni, N; Novák, P; Ranno, S

    2007-01-01

    Twenty two patients with gender dysphoria underwent neo-phalloplasties using a novel technique. Latissimus dorsi musculocutaneus re-innervated free flap was used to allow voluntary rigidity of the neo-penis. From the first 22 patients, 18 have obtained motoric function of reconstructed penis; the "paradox erection" was obtained. 14 patients came for examination after a follow-up period of mean 26.4 months. We evaluated the motility and shape changes of neo-phallus measuring its different size and dimension during relax and muscle contraction. The range of neo-phallus length in relaxed position was between 7 and 17 cm (mean 12.2 cm), its circumference in the same position had a range between 13 and 20 cm (mean 13.7 cm). All patients were able to contract the muscle with an average length reduction of 3.08 cm and an average circumference enlargement of 4 cm. In this study, the dimensions and motility were quantified demonstrating the neo-phallus function and size changes during sexual intercourse.

  15. [The penis prolongation and augmentation combined with autologous granular fat injection and silicone implantation].

    PubMed

    Xie, Yang-chun; Zhang, Yang; Fan, Jin-cai; Liu, Yuan-bo; Liu, Li-qiang; Wang, Qian

    2007-07-01

    To prevent the retraction of the penis after prolongation and augmentation. After all the superficial and part of the deep suspensory ligament amputation, we implanted the silicon sheet (the length 2.3-3.6 cm, the width 1.5-2.5 cm, the thickness 2-3 mm) and injected autologous granular fat (30-48 ml) into penis. 16 patients (age 22-63 years, averagely 38 years) underwent this kind operation, the prolongation length is 1.8-5.1 cm, the average was 2.91 cm, the increased diameter of penis was 0.6-1 cm, the average is 0.85 cm, the following period is 3 months to 2 years. The results are satisfactory with the penis retraction less than 8%, and less than 10% decrease in diameter. This method is an ideal way of the penis prolongation and augmentation, the implantation of the silicon sheet is effective way to prevent the retraction of the penis.

  16. Relationship of the length of the first stage of labor to the length of the second stage.

    PubMed

    Nelson, David B; McIntire, Donald D; Leveno, Kenneth J

    2013-07-01

    To evaluate the relationship between the lengths of the first and second stages of labor. In this observational study of women delivering at our hospital, the onset of the first stage of labor was defined as admission at 3-cm to 4-cm dilatation in the presence of uterine contractions with or without rupture of membranes. This study was limited to nulliparous women with a singleton, cephalic live birth at 37 0/7 weeks of gestation or more. Women presenting with more advanced cervical dilatation (greater than 4 cm), prior cesarean delivery, diabetes, hypertension, and placental accidents were excluded. Each woman was analyzed based on her specific lengths of first and second stages of labor, that is, paired observations for each woman. Between January 1, 2001, and June 30, 2012, a total of 172,522 women were delivered and 12,523 (7.3%) met the inclusion criteria. The 95 percentile was 15.6 and 2.9 hours for the first and second stages, respectively. Women with first stages greater than the 95 percentile had a 16.3% rate of a second-stage length greater than the 95 percentile compared with 4.5% (P<.001) in women with first stages less than the 95 percentile. This relationship persisted when analyzed for variables influencing labor to include neonate birth weight, epidural analgesia, or maternal size. Overall, the length of the second stage significantly increased concomitantly with increasing length of the first stage (P<.001). II.

  17. Muscle force loss and soreness subsequent to maximal eccentric contractions depend on the amount of fascicle strain in vivo.

    PubMed

    Guilhem, G; Doguet, V; Hauraix, H; Lacourpaille, L; Jubeau, M; Nordez, A; Dorel, S

    2016-06-01

    Defining the origins of muscle injury has important rehabilitation and exercise applications. However, current knowledge of muscle damage mechanics in human remains unclear in vivo. This study aimed to determine the relationships between muscle-tendon unit mechanics during maximal eccentric contractions and the extent of subsequent functional impairments induced by muscle damage. The length of the muscle-tendon unit, fascicles and tendinous tissues was continuously measured on the gastrocnemius medialis using ultrasonography, in time with torque, during 10 sets of 30 maximal eccentric contractions of plantar flexors at 45°s(-1) , in seventeen participants. Muscle-tendon unit, fascicles and tendinous tissues were stretched up to 4.44 ± 0.33 cm, 2.31 ± 0.64 cm and 1.92 ± 0.61 cm respectively. Fascicle stretch length, lengthening amplitude and negative fascicle work beyond slack length were significantly correlated with the force decrease 48 h post-exercise (r = 0.51, 0.47 and 0.68, respectively; P < 0.05). This study demonstrates that the strain applied to human muscle fibres during eccentric contractions strongly influences the magnitude of muscle damage in vivo. Achilles tendon compliance decreases the amount of strain, while architectural gear ratio may moderately contribute to attenuating muscle fascicle lengthening and hence muscle damage. Further studies are necessary to explore the impact of various types of task to fully understand the contribution of muscle-tendon interactions during active lengthening to muscle damage. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  18. Fetal laceration injury during cesarean section and its long-term sequelae: a case report.

    PubMed

    Gajjar, Ketan; Spencer, Chris

    2009-10-01

    This case report illustrates the cosmetic outcome of a scalpel-related laceration injury sustained to a newborn infant that occurred during the course of an elective cesarean section for breech presentation. This buttock laceration was noted to be 2 cm in length at the time of birth. Twelve years later, the same scar had migrated in a cephalad direction and had increased to 10 cm in length.

  19. Multi-chord fiber-coupled interferometer with a long coherence length laser

    NASA Astrophysics Data System (ADS)

    Merritt, Elizabeth C.; Lynn, Alan G.; Gilmore, Mark A.; Hsu, Scott C.

    2012-03-01

    This paper describes a 561 nm laser heterodyne interferometer that provides time-resolved measurements of line-integrated plasma electron density within the range of 1015-1018 cm-2. Such plasmas are produced by railguns on the plasma liner experiment, which aims to produce μs-, cm-, and Mbar-scale plasmas through the merging of 30 plasma jets in a spherically convergent geometry. A long coherence length, 320 mW laser allows for a strong, sub-fringe phase-shift signal without the need for closely matched probe and reference path lengths. Thus, only one reference path is required for all eight probe paths, and an individual probe chord can be altered without altering the reference or other probe path lengths. Fiber-optic decoupling of the probe chord optics on the vacuum chamber from the rest of the system allows the probe paths to be easily altered to focus on different spatial regions of the plasma. We demonstrate that sub-fringe resolution capability allows the interferometer to operate down to line-integrated densities of the order of 5 × 1015 cm-2.

  20. Needle thoracostomy in the treatment of a tension pneumothorax in trauma patients: what size needle?

    PubMed

    Zengerink, Imme; Brink, Peter R; Laupland, Kevin B; Raber, Earl L; Zygun, Dave; Kortbeek, John B

    2008-01-01

    A tension pneumothorax requires immediate decompression using a needle thoracostomy. According to advanced trauma life support guidelines this procedure is performed in the second intercostal space (ICS) in the midclavicular line (MCL), using a 4.5-cm (2-inch) catheter (5-cm needle). Previous studies have shown a failure rate of up to 40% using this technique. Case reports have suggested that this high failure rate could be because of insufficient length of the needle. To analyze the average chest wall thickness (CWT) at the second ICS in the MCL in a trauma population and to evaluate the length of the needle used in needle thoracostomy for emergency decompression of tension pneumothoraces. Retrospective review of major trauma admissions (Injury Severity Score >12) at the Foothills Medical Centre in Calgary, Canada, who underwent a computed tomography chest scan admitted in the period from October 2001 until March 2004. Subgroup analysis on men and women, <40 years of age and >/=40 years of age was defined a priori. CWT was measured to the nearest 0.01 cm at the second ICS in the MCL. The mean CWT in the 604 male patients and 170 female patients studied averaged 3.50 cm at the left second ICS MCL and 3.51 cm on the right. The mean CWT was significantly higher for women than men (p < 0.0001). About 9.9% to 19.3% of the men had a CWT >4.5 cm and 24.1% to 35.4% of the women studied. A catheter length of 4.5 cm may not penetrate the chest wall of a substantial amount (9.9%-35.4%) of the population, depending on age and gender. This study demonstrates the need for a variable needle length for relief of a tension pneumothorax in certain population groups to improve effectiveness of needle thoracostomy.

  1. Estimation of body density based on hydrostatic weighing without head submersion in young Japanese adults.

    PubMed

    Demura, S; Sato, S; Kitabayashi, T

    2006-06-01

    This study examined a method of predicting body density based on hydrostatic weighing without head submersion (HWwithoutHS). Donnelly and Sintek (1984) developed a method to predict body density based on hydrostatic weight without head submersion. This method predicts the difference (D) between HWwithoutHS and hydrostatic weight with head submersion (HWwithHS) from anthropometric variables (head length and head width), and then calculates body density using D as a correction factor. We developed several prediction equations to estimate D based on head anthropometry and differences between the sexes, and compared their prediction accuracy with Donnelly and Sintek's equation. Thirty-two males and 32 females aged 17-26 years participated in the study. Multiple linear regression analysis was performed to obtain the prediction equations, and the systematic errors of their predictions were assessed by Bland-Altman plots. The best prediction equations obtained were: Males: D(g) = -164.12X1 - 125.81X2 - 111.03X3 + 100.66X4 + 6488.63, where X1 = head length (cm), X2 = head circumference (cm), X3 = head breadth (cm), X4 = head thickness (cm) (R = 0.858, R2 = 0.737, adjusted R2 = 0.687, standard error of the estimate = 224.1); Females: D(g) = -156.03X1 - 14.03X2 - 38.45X3 - 8.87X4 + 7852.45, where X1 = head circumference (cm), X2 = body mass (g), X3 = head length (cm), X4 = height (cm) (R = 0.913, R2 = 0.833, adjusted R2 = 0.808, standard error of the estimate = 137.7). The effective predictors in these prediction equations differed from those of Donnelly and Sintek's equation, and head circumference and head length were included in both equations. The prediction accuracy was improved by statistically selecting effective predictors. Since we did not assess cross-validity, the equations cannot be used to generalize to other populations, and further investigation is required.

  2. Inert gas ion thruster

    NASA Technical Reports Server (NTRS)

    Ramsey, W. D.

    1980-01-01

    Inert gas performance with three types of 12 cm diameter magnetoelectrostatic containment (MESC) ion thrusters was tested. The types tested included: (1) a hemispherical shaped discharge chamber with platinum cobalt magnets; (2) three different lengths of the hemispherical chambers with samarium cobalt magnets; and (3) three lengths of the conical shaped chambers with aluminum nickel cobalt magnets. The best argon performance was produced by a 8.0 cm long conical chamber with alnico magnets. The best xenon high mass utilization performance was obtained with the same 8.0 cm long conical thruster. The hemispherical thruster obtained 75 to 87% mass utilization at 185 to 205 eV/ion of singly charged ion equivalent beam.

  3. Length-weight and length-length relationships of common carp (Cyprinus carpio L.) in the middle and southern Iraq provinces

    NASA Astrophysics Data System (ADS)

    Al-jebory, Taymaa A.; Das, Simon K.; Usup, Gires; Bakar, Y.; Al-saadi, Ali H.

    2018-04-01

    In this study, length-weight and length-length relationships of common carp (Cyprinus carpio L.) in the middle and southern Iraq provinces were determined. Fish specimens were procured from seven provinces from July to December, 2015. A negative and positive allometric growth pattern was obtained, where the total length (TL) ranged from 25.60 cm to 33.53 cm, and body weight (BW) ranged from 700 g to 1423 g. Meanwhile, the lowest of 1.03 and highest of 3.54 in "b" value was recorded in group F and group C, respectively. Therefore, Fulton condition factor (K) range from 2.57 to 4.94. While, relative condition factor (Kn) was in the ranged of 0.95 to 1.01. A linear relationship between total length (TL) and standard length (SL) among the provinces for fish groups was obtained. The variances in "b" value ranged from 0.10 to 0.93 with correlation coefficient (r2) of 0.02 to 0.97. This research could be used as a guide to study the ecology and biology of common Carp (Cyprinus carpio L.) in the middle and southern Iraq provinces.

  4. Proper catheter selection for needle thoracostomy: a height and weight-based criteria.

    PubMed

    Powers, William F; Clancy, Thomas V; Adams, Ashley; West, Tonnya C; Kotwall, Cyrus A; Hope, William W

    2014-01-01

    Obesity increases the incidence of mortality in trauma patients. Current Advanced Trauma Life Support guidelines recommend using a 5-cm catheter at the second intercostal (ICS) space in the mid-clavicular line to treat tension pneumothoraces. Our study purpose was to determine whether body mass index (BMI) predicted the catheter length needed for needle thoracostomy. We retrospectively reviewed trauma patients undergoing chest computed tomography scans January 2004 through September 2006. A BMI was calculated for each patient, and the chest wall thickness (CWT) at the second ICS in the mid-clavicular line was measured bilaterally. Patients were grouped by BMI as underweight (≤ 18.5 kg/m2), normal weight (18.6-24.9 kg/m(2)), overweight (25-29.9 kg/m(2)), or obese (≥ 30 kg/m(2)). Three hundred twenty-six patients were included in the study; 70% were male. Ninety-four percent of patients experienced blunt trauma. Sixty-three percent of patients were involved in a motor vehicle collision. The average BMI was 29 [SD 7.8]. The average CWT was 6.2 [SD 1.9]cm on the right and 6.3 [SD 1.9]cm on the left. As BMI increased, a statistically significant (p<0.0001) CWT increase was observed in all BMI groups. There were no significant differences in ISS, ventilator days, ICU length of stay, or overall length of stay among the groups. As BMI increases, there is a direct correlation to increasing CWT. This information could be used to quickly select an appropriate needle length for needle thoracostomy. The average patient in our study would require a catheter length of 6-6.5 cm to successfully decompress a tension pneumothorax. There are not enough regionally available data to define the needle lengths needed for needle thoracostomy. Further study is required to assess the feasibility and safety of using varying catheter lengths. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Prognostic role of initial pan-endoscopic tumor length at diagnosis in operable esophageal squamous cell carcinoma undergoing esophagectomy with or without neoadjuvant concurrent chemoradiotherapy

    PubMed Central

    Lin, Chen-Sung; Liu, Chao-Yu; Cheng, Chih-Tao; Tsai, Yu-Chen; Chiou, Lun-Wei; Lee, Ming-Yuan

    2017-01-01

    Background The objective of this study was to appraise the prognostic role of initial pan-endoscopic tumor length at diagnosis within or between operable esophageal squamous cell carcinoma (ESCC) undergoing upfront esophagectomy or neoadjuvant concurrent chemoradiotherapy (nCCRT) followed by esophagectomy. Methods Between Jan 2001 and Dec 2013 in Koo-Foundation Sun Yat-sen Cancer Center in Taiwan, 101 ESCC patients who underwent upfront esophagectomy (surgery group) and 128 nCCRT followed by esophagectomy (nCCRT-surgery group) were retrospectively collected. Prognostic variables, including initial pan-endoscopic tumor length at diagnosis (sub-grouped ≤3, 3–5 and >5 cm), status of circumferential resection margin (CRM), and pathological T/N/M-status and cancer stage, were appraised within or between surgery and nCCRT-surgery groups. Results Within surgery group, longer initial pan-endoscopic tumor length at diagnosis (≤3, 3–5 and >5 cm; HR =1.000, 1.688 and 4.165; P=0.007) was an independent prognostic factor that correlated with advanced T/N/M-status, late cancer stage, and CRM invasion (all’s P<0.001). Based on the initial pan-endoscopic tumor length at diagnosis ≤3, 3–5 and >5 cm, nCCRT-surgery group had a poorer (P=0.039), similar (P=0.447) and better (P<0.001) survivals than did surgery group, respectively. For those with initial pan-endoscopic tumor length at diagnosis >5 cm, nCCRT-surgery group had more percentage of T0/N0-status and stage 0 (all’s P<0.05), and fewer rate of CRM invasion (P=0.036) than did surgery group. Conclusions Initial pan-endoscopic tumor length at diagnosis could be a criterion to select proper ESCC cases for nCCRT followed by esophagectomy to improve survival and reduce CRM invasion. PMID:29221296

  6. Proximal hamstring morphology and morphometry in men: an anatomic and MRI investigation.

    PubMed

    Storey, R N; Meikle, G R; Stringer, M D; Woodley, S J

    2016-12-01

    The proximal musculo-tendinous junction (MTJ) is a common site of hamstring strain injury but the anatomy of this region is not well defined. A morphometric analysis of the proximal MTJs of biceps femoris long head (BFlh), semitendinosus (ST), and semimembranosus (SM) was undertaken from dissection of 10 thighs from five male cadavers and magnetic resonance imaging of 20 thighs of 10 active young men. The length, volume, and cross-sectional area of the proximal tendon, MTJ and muscle belly, and muscle-tendon interface area were calculated. In both groups, MTJs were reconstructed three-dimensionally. The proximal tendons and MTJs were expansive, particularly within SM and BFlh. Morphology varied between muscles although length measurements within individual muscles were similar in cadavers and young men. Semimembranosus had the longest proximal tendon (cadavers: mean 33.6 ± 2.0 cm; young men: mean 31.7 ± 1.6 cm) and MTJ (>20 cm in both groups) and the greatest muscle-tendon interface area, followed by BFlh and ST. Mean muscle belly volumes were more than three times greater in young men than elderly male cadavers (P < 0.001). These unique morphometric data contribute to a better understanding of hamstring anatomy, an important factor in the pathogenesis of hamstring strain injury. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Geodesy by radio interferometry - Effects of atmospheric modeling errors on estimates of baseline length

    NASA Technical Reports Server (NTRS)

    Davis, J. L.; Herring, T. A.; Shapiro, I. I.; Rogers, A. E. E.; Elgered, G.

    1985-01-01

    Analysis of very long baseline interferometry data indicates that systematic errors in prior estimates of baseline length, of order 5 cm for approximately 8000-km baselines, were due primarily to mismodeling of the electrical path length of the troposphere and mesosphere ('atmospheric delay'). Here observational evidence for the existence of such errors in the previously used models for the atmospheric delay is discussed, and a new 'mapping' function for the elevation angle dependence of this delay is developed. The delay predicted by this new mapping function differs from ray trace results by less than approximately 5 mm, at all elevations down to 5 deg elevation, and introduces errors into the estimates of baseline length of less than about 1 cm, for the multistation intercontinental experiment analyzed here.

  8. Predicting active-layer soil thickness using topographic variables at a small watershed scale

    PubMed Central

    Li, Aidi; Tan, Xing; Wu, Wei; Liu, Hongbin; Zhu, Jie

    2017-01-01

    Knowledge about the spatial distribution of active-layer (AL) soil thickness is indispensable for ecological modeling, precision agriculture, and land resource management. However, it is difficult to obtain the details on AL soil thickness by using conventional soil survey method. In this research, the objective is to investigate the possibility and accuracy of mapping the spatial distribution of AL soil thickness through random forest (RF) model by using terrain variables at a small watershed scale. A total of 1113 soil samples collected from the slope fields were randomly divided into calibration (770 soil samples) and validation (343 soil samples) sets. Seven terrain variables including elevation, aspect, relative slope position, valley depth, flow path length, slope height, and topographic wetness index were derived from a digital elevation map (30 m). The RF model was compared with multiple linear regression (MLR), geographically weighted regression (GWR) and support vector machines (SVM) approaches based on the validation set. Model performance was evaluated by precision criteria of mean error (ME), mean absolute error (MAE), root mean square error (RMSE), and coefficient of determination (R2). Comparative results showed that RF outperformed MLR, GWR and SVM models. The RF gave better values of ME (0.39 cm), MAE (7.09 cm), and RMSE (10.85 cm) and higher R2 (62%). The sensitivity analysis demonstrated that the DEM had less uncertainty than the AL soil thickness. The outcome of the RF model indicated that elevation, flow path length and valley depth were the most important factors affecting the AL soil thickness variability across the watershed. These results demonstrated the RF model is a promising method for predicting spatial distribution of AL soil thickness using terrain parameters. PMID:28877196

  9. Characterization of nitrosoalkane binding and activation of soluble guanylate cyclase.

    PubMed

    Derbyshire, Emily R; Tran, Rosalie; Mathies, Richard A; Marletta, Michael A

    2005-12-13

    Soluble guanylate cyclase (sGC) is the primary receptor for the signaling agent nitric oxide (NO). Electronic absorption and resonance Raman spectroscopy were used to show that nitrosoalkanes bind to the heme of sGC to form six-coordinate, low-spin complexes. In the sGC-nitrosopentane complex, a band assigned to an Fe-N stretching vibration is observed at 543 cm(-)(1) which is similar to values reported for other six-coordinate NO-bound hemoproteins. Nitrosoalkanes activate sGC 2-6-fold and synergize with YC-1, a synthetic benzylindazole derivative, to activate the enzyme 11-47-fold. In addition, the observed off-rates of nitrosoalkanes from sGC were found to be dependent on the alkyl chain length. A linear correlation was found between the observed off-rates and the alkyl chain length which suggests that the sGC heme has a large hydrophobic distal ligand-binding pocket. Together, these data show that nitrosoalkanes are a novel class of heme-based sGC activators and suggest that heme ligation is a general requirement for YC-1 synergism.

  10. Study on the role of active radicals on plasma sterilization inside small diameter flexible polymeric tubes

    NASA Astrophysics Data System (ADS)

    Mstsuura, Hiroto; Fujiyama, Takatomo; Okuno, Yasuki; Furuta, Masakazu; Okuda, Shuichi; Takemura, Yuichiro

    2015-09-01

    Recently, atmospheric pressure discharge plasma has gathered attention in various fields. Among them, plasma sterilization with many types of plasma source has studied for decades and its mechanism is still an open question. If active radicals produced in plasma has main contribution of killing bacterias, direct contact of the so-called plasma flame might not be necessary. To confirm this, sterilization inside small diameter flexible polymeric tubes is studied in present work. DBD type plasma jet is produce by flowing helium gas in a glass tube. A long polymeric tube is connected and plasma jet is introduced into it. Plasma flame length depends on helium gas flow rate, but limited to about 10 cm in our experimental condition. E.colis set at the exit plasma source is easily killed during 10 min irradiation. At the tube end (about 20 cm away from plasma source exit), sterilization is possible with 30 min operation. This result shows that active radical is produced with helium plasma and mist contained in sample, and it can be transferred more than 20 cm during it life time. More plasma diagnostic data will also be shown at the conference. This work was partially supported by the ''ZE Research Program, IAE(ZE27B-4).

  11. Distribution of Pb-210 in Spanish Soils: Study of the Atmospheric Contribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrera, M.; Romero, M. L.; Valino, F.

    The vertical distribution of activity and inventories of atmospheric Pb-210 is being studied in Spanish soils, aiming to establish the reference levels in the zone, based on the type of soil and the annual rainfall. A homogeneous distribution grid (approx. 150x150 km each cell) has been established covering the peninsular land, trying to combine the varying soil types (remaining undisturbed for the last 50 years) and the closeness to meteorological stations. Sampling has been performed by extracting undisturbed soil cylinders of 6 cm diameter and 120 cm length, with an impact penetrometer, and the soil cores have been sectioned inmore » slices of 3 cm thick. The analysis of Pb-210 has been performed using a gamma spectrometry system with coaxial HPGe detector sensitive at low energies (46.5 keV emission). The geometry of measured samples is thin enough (approx. 2 cm) to minimize self-absorption corrections. The work presents the results obtained so far. The Pb-210 activity profiles exhibit the characteristic decreasing shape with depth, showing maximum levels at the surface, and reaching the equilibrium activity with Ra-226 at a maximum depth depending on different environmental conditions. The unsupported Pb-210 inventory values are in the usual range (1000-5000 Bq/m{sup 2}), showing a positive correlation with the averaged annual rainfall. These reference levels could be used in posterior studies of anthropogenic alteration of soils, evaluation of erosion and desertification processes.« less

  12. Creation of short microwave ablation zones: In Vivo Characterization of single and paired Modified Triaxial Antennas Laboratory Investigation

    PubMed Central

    Lubner, Meghan G.; Ziemlewicz, Tim J; Hinshaw, J. Louis; Lee, Fred T.; Sampson, Lisa J.; Brace, Chris L.

    2014-01-01

    Purpose To characterize modified triaxial microwave antennas configured to produce short ablation zones. Materials and Methods 50 single- and 27 paired-antenna hepatic ablations were performed in domestic swine (n=11) with 17-gauge, gas-cooled modified triaxial antennas powered at 65W from a 2.45 GHz generator. Single-antenna ablations were performed at 2 (n=16), 5 (n=21), and 10 (n=13) minutes. Paired-antenna ablations were performed at 1-cm and 2-cm spacing for 5 (n=7, n=8) and 10 minutes (n=7, n=5). Mean transverse width, length and aspect ratio of sectioned ablation zones were measured and compared. Results For single antennas, mean ablation zone length was 2.9±0.45, 3.5±0.55 and 4.2±0.40 cm at 2, 5, and 10 minutes respectively. Mean width was 1.8±0.3, 2.0±0.32, 2.5±0.25 cm at 2, 5, and 10 minutes. For paired antennas, mean length at 5 min 1 and 2 cm and 10 min 1 and 2 cm spacing was 4.2±0.9, 4.4±0.9, 4.8±0.5 and 4.3±0.9 cm respectively. Mean width was 3.1±1.0, 4.0±0.8 and 3.8±0.4, 4.2±0.6 cm respectively. Paired-antenna ablations were more spherical (aspect ratios 0.72-0.79 for 5-10 min) than single-antenna ablations (0.57-0.59). For paired-antenna ablations, 1 cm spacing appeared optimal, with improved circularity and decreased clefting compared to 2 cm spacing (circ 1 cm 0.85, 2 cm 0.78). Conclusion Modified triaxial antennas can generate relatively short, spherical ablation zones. Paired-antenna ablations were rounder and larger in transverse dimension compared to single antenna ablations, with 1 cm spacing optimal for confluence of the ablation zone. PMID:25156644

  13. Stereological and Morphometric Analysis of MRI Chiari Malformation Type-1

    PubMed Central

    Alkoç, Ozan Alper; Songur, Ahmet; Eser, Olcay; Toktas, Muhsin; Esi, Ertap; Haktanir, Alpay

    2015-01-01

    Objective In this study, we aimed to investigate the underlying ethiological factors in chiari malformation (CM) type-I (CMI) via performing volumetric and morphometric length-angle measurements. Methods A total of 66 individuals [33 patients (20-65 years) with CMI and 33 control subjects] were included in this study. In sagittal MR images, tonsillar herniation length and concurrent anomalies were evaluated. Supratentorial, infratentorial, and total intracranial volumes were measured using Cavalieri method. Various cranial distances and angles were used to evaluate the platybasia and posterior cranial fossa (PCF) development. Results Tonsillar herniation length was measured 9.09±3.39 mm below foramen magnum in CM group. Tonsillar herniation/concurrent syringomyelia, concavity/defect of clivus, herniation of bulbus and fourth ventricle, basilar invagination and craniovertebral junction abnormality rates were 30.3, 27, 18, 2, 3, and 3 percent, respectively. Absence of cisterna magna was encountered in 87.9% of the patients. Total, IT and ST volumes and distance between Chamberlain line and tip of dens axis, Klaus index, clivus length, distance between internal occipital protuberance and opisthion were significantly decreased in patient group. Also in patient group, it was found that Welcher basal angle/Boogard angle increased and tentorial slope angle decreased. Conclusion Mean cranial volume and length-angle measurement values significantly decreased and there was a congenital abnormality association in nearly 81.5 percent of the CM cases. As a result, it was concluded that CM ethiology can be attributed to multifactorial causes. Moreover, congenital defects can also give rise to this condition. PMID:26713146

  14. B-mode ultrasonography biometry of the Amazon Parrot (Amazona aestiva) eye.

    PubMed

    Lehmkuhl, Ricardo C; Almeida, Mariana F; Mamprim, Maria J; Vulcano, Luiz C

    2010-09-01

    Ultrasonographic evaluation of the eye is a relatively recent addition to routine ophthalmic diagnostics in small animal ophthalmology. Some parameters for ophthalmic biometry have been established. There are few studies in clinical avian ophthalmology that describe ultrasound images of eye in some nocturnal avian species and in other birds that do not belong to the Brazilian fauna, but the psittacine family is not represented. The purpose of this study was to describe the following measurements: the distances between cornea and anterior lens capsule (D1) between the anterior and posterior lens capsule (D2), between posterior lens capsule and optic papilla (D3) and the axial length. Sixty four transpalpebral ocular ultrasound examinations were performed on 32 Blue fronted Amazon parrots (Amazona aestiva) with no history of previous ophthalmic disease. The measurements were taken in sagital planes using a 10 MHz linear probe without a standoff pad. The mean values for the left eye were; D1 0.17 ± 0.03 cm, D2 0.35 ± 0.02 cm, D3 0.73 ± 0.04 cm and the axial length 1.26 ± 0.06 cm. In the right eye D1 0.17 ± 0.02 cm, D2 0.34 ± 0.02 cm, D3 0.74 ± 0.03 cm and the axial length 1.25 ± 0.05 cm. No significant statistical difference was observed among the birds or between the left and right eye. The description of these parameters will allow the veterinary practitioner to evaluate the structural changes that specific diseases may cause in these animals.

  15. Accuracy of Jump-Mat Systems for Measuring Jump Height.

    PubMed

    Pueo, Basilio; Lipinska, Patrycja; Jiménez-Olmedo, José M; Zmijewski, Piotr; Hopkins, Will G

    2017-08-01

    Vertical-jump tests are commonly used to evaluate lower-limb power of athletes and nonathletes. Several types of equipment are available for this purpose. To compare the error of measurement of 2 jump-mat systems (Chronojump-Boscosystem and Globus Ergo Tester) with that of a motion-capture system as a criterion and to determine the modifying effect of foot length on jump height. Thirty-one young adult men alternated 4 countermovement jumps with 4 squat jumps. Mean jump height and standard deviations representing technical error of measurement arising from each device and variability arising from the subjects themselves were estimated with a novel mixed model and evaluated via standardization and magnitude-based inference. The jump-mat systems produced nearly identical measures of jump height (differences in means and in technical errors of measurement ≤1 mm). Countermovement and squat-jump height were both 13.6 cm higher with motion capture (90% confidence limits ±0.3 cm), but this very large difference was reduced to small unclear differences when adjusted to a foot length of zero. Variability in countermovement and squat-jump height arising from the subjects was small (1.1 and 1.5 cm, respectively, 90% confidence limits ±0.3 cm); technical error of motion capture was similar in magnitude (1.7 and 1.6 cm, ±0.3 and ±0.4 cm), and that of the jump mats was similar or smaller (1.2 and 0.3 cm, ±0.5 and ±0.9 cm). The jump-mat systems provide trustworthy measurements for monitoring changes in jump height. Foot length can explain the substantially higher jump height observed with motion capture.

  16. Reconstruction with distraction osteogenesis for juxta-articular nonunions with bone loss.

    PubMed

    Kabata, Tamon; Tsuchiya, Hiroyuki; Sakurakichi, Keisuke; Yamashiro, Teruhisa; Watanabe, Koji; Tomita, Kasuro

    2005-06-01

    Nonunions of a juxta-articular lesion with bone loss, which represent a challenging therapeutic problem, were treated using external fixation and distraction osteogenesis. Seven juxta-articular nonunions (five septic and two aseptic) were treated. The location of the nonunion was the distal femur in four patients, the proximal tibia in one patient, and the distal tibia in two patients. All of them were located within 5 cm from the affected joints. Preoperative limb shortening was present in six cases, averaging 2.9 cm (range, 1-7 cm). The reconstructive procedure consisted of refreshment of the nonunion site, deformity correction, stabilization by external fixation, and lengthening to eliminate leg length discrepancy or to fill the defect. Shortening-distraction was applied to six patients and bone transport to one patient for reconstruction. Intramedullary nailing to reduce the duration of external fixation was simultaneously performed in two cases. All the patients had at least 1 year of follow-up evaluation. Osseous union without angular deformity or leg length discrepancy greater than 1 cm was achieved in all patients. The mean amount of lengthening was 5.8 cm (range, 2.2-10.0 cm). The mean external fixation period was 219 days (range, 98-317 days), and the mean external fixation index was 34.4 days/cm (range, 24.5-47.6 days/cm). All patients reported excellent pain reduction. There were no recurrences of infection in five patients with prior history of osteomyelitis. The functional results were categorized as excellent in two, good in three, and fair in two. Despite the length of postoperative external fixation, distraction osteogenesis can be a valuable alternative for the treatment of juxta-articular nonunions.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, S St.; Argento, D; Stewart, R

    Purpose: The University of Washington Medical Center offers neutron therapy for the palliative and definitive treatment of selected cancers. In vivo field verification has the potential to improve the safe and effective delivery of neutron therapy. We propose a portal imaging method that relies on the creation of positron emitting isotopes (11C and 15O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects annihilation photons. The spatial pattern of activity produced in the PMMA plate provides information to reconstruct themore » neutron fluence map needed to confirm treatment delivery. Methods: We used MCNP to simulate the accumulation of 11C activity in a slab of PMMA 2 mm thick, and GATE was used to simulate the sensitivity and spatial resolution of a prototype imaging system. BGO crystal thicknesses of 1 cm, 2 cm and 3 cm were simulated with detector separations of 2 cm. Crystal pitches of 2 mm and 4 mm were evaluated. Back-projection of the events was used to create a planar image. The spatial resolution was taken to be the FWHM of the reconstructed point source image. Results: The system sensitivity for a point source in the center of the field of view was found to range from 58% for 1 cm thick BGO with 2 mm crystal pitch to 74% for the 3 cm thick BGO crystals with 4 mm crystal pitch. The spatial resolution at the center of the field of view was found to be 1.5 mm for the system with 2 mm crystal pitch and 2.8 mm for the system with the 4 mm crystal pitch. Conclusion: BGO crystals with 4 mm crystal pitch and 3 cm length would offer the best sensitivity reader.« less

  18. Growth, mortality and reproduction of the blue tilapia Oreochromis aureus (Perciformes: Cichlidae) in the Aguamilpa Reservoir, Mexico.

    PubMed

    Peña Messina, Emilio; Tapia Varela, Raul; Velázquez Abunader, José Iván; Orbe Mendoza, Alma Araceli; Velazco Arce, Javier Marcial de Jesús Ruiz

    2010-12-01

    Tilapia production has increased in Aguamilpa Reservoir, in Nayarit, Mexico, in the last few years and represents a good economic activity for rural communities and the country. We determined growth parameters, mortality and reproductive aspects for 2413 specimens of blue tilapia Oreochromis aureus in this reservoir. Samples were taken monthly from July 2000 through June 2001, of which 1 371 were males and 1 042 were females. Standard length (SL) and total weight (TW) were measured in each organism. The SL/TW relationships through power models for sexes were determined. The growth parameters L infinity k, and t0 of the von Bertalanffy equation were estimated using frequency distribution of length through ELEFAN-I computer program. Finally the reproductive cycle and size of first maturity were established using morph chromatic maturity scale. The results suggested that the males and females had negative allometric growth (b < 3). Significant differences were found between SL/TW model for the sexes, suggesting separate models for males and females. Results indicate that there are no differences in growth rates between sexes; the proposed parameters were L infinity = 43.33 cm standard length, k = 0.36/year and t0 = -0.43 years. Natural and fishing mortality coefficients were 0.83/year and 1.10/year, respectively. The estimated exploitation rate (0.57/year) suggested that during the study period the fishery showed signs of overfishing. Blue tilapia reproduces year-round; the highest activity occurs from January through May and size of first maturity was 23 cm SL. We conclude that it is necessary to establish a minimum catch size in this reservoir based on the reproductive behavior of this species.

  19. Optical mode engineering and high power density per facet length (>8.4 kW/cm) in tilted wave laser diodes

    NASA Astrophysics Data System (ADS)

    Ledentsov, N. N.; Shchukin, V. A.; Maximov, M. V.; Gordeev, N. Y.; Kaluzhniy, N. A.; Mintairov, S. A.; Payusov, A. S.; Shernyakov, Yu. M.

    2016-03-01

    Tilted Wave Lasers (TWLs) based on optically coupled thin active waveguide and thick passive waveguide offer an ultimate solution for thick-waveguide diode laser, preventing catastrophic optical mirror damage and thermal smile in laser bars, providing robust operation in external cavity modules thus enabling wavelength division multiplexing and further increase in brightness enabling direct applications of laser diodes in the mainstream material processing. We show that by proper engineering of the waveguide one can realize high performance laser diodes at different tilt angles of the vertical lobes. Two vertical lobes directed at various angles (namely, +/-27° or +/-9°) to the junction plane are experimentally realized by adjusting the compositions and the thicknesses of the active and the passive waveguide sections. The vertical far field of a TWL with the two +/-9° vertical beams allows above 95% of all the power to be concentrated within a vertical angle below 25°, the fact which is important for laser stack applications using conventional optical coupling schemes. The full width at half maximum of each beam of the value of 1.7° evidences diffraction- limited operation. The broad area (50 μm) TWL chips at the cavity length of 1.5 mm reveal a high differential efficiency ~90% and a current-source limited pulsed power >42W for as-cleaved TWL device. Thus the power per facet length in a laser bar in excess of 8.4 kW/cm can be realized. Further, an ultimate solution for the smallest tilt angle is that where the two vertical lobes merge forming a single lobe directed at the zero angle is proposed.

  20. Maternal hypothalamus-pituitary-adrenal (HPA) system activity and stress during pregnancy: Effects on gestational age and infant's anthropometric measures at birth.

    PubMed

    Gilles, Maria; Otto, Henrike; Wolf, Isabell A C; Scharnholz, Barbara; Peus, Verena; Schredl, Michael; Sütterlin, Marc W; Witt, Stephanie H; Rietschel, Marcella; Laucht, Manfred; Deuschle, Michael

    2018-04-22

    Prenatal maternal stress might be a risk for the developing fetus and may have long-lasting effects on child and adult vulnerability to somatic and psychiatric disease. Over-exposure of the unborn to excess glucocorticoids and subsequent alteration of fetal development is hypothesized to be one of the key mechanisms linking prenatal stress with negative child outcome. In this prospective longitudinal study, mothers-to-be (n = 405) in late pregnancy (36.8 ± 1.9 weeks of gestational age) and their singleton neonates were studied. We investigated the impact of different prenatal stress indices derived from six stress variables (perceived stress, specific prenatal worries, negative life events, symptoms of depression, trait anxiety, neuroticism) and diurnal maternal saliva cortisol secretion on gestational age and anthropometric measures at birth. Maternal prenatal distress during late gestation was associated with significant reduction in birth weight (-217 g; p = .005), birth length (-1.2 cm; p = .005) and head circumference (-0.8 cm; p = .001). Prenatal stress was modestly but significantly associated with altered diurnal cortisol pattern (flattened cortisol decline and higher evening cortisol), which in turn was significantly related to reduced length of gestation. No evidence for a profound interaction between maternal cortisol level in late pregnancy and infant's anthropometric measures at birth (i.e., birth weight, length, head circumference) was found. Prenatal stress is associated with flattened circadian saliva cortisol profiles and reduced infant's anthropometric measures at birth. HPA system activity during pregnancy may be related to low gestational age. The effect of prenatal stress might be partly mediated by maternal-placental-fetal neuroendocrine mechanisms especially the dysregulation of diurnal cortisol profile. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Effects of consumption-oriented versus trophy-oriented fisheries on Muskellunge population size structure in northern Wisconsin

    USGS Publications Warehouse

    Faust, Matthew D.; Hansen, Michael J.

    2016-01-01

    To determine whether a consumption-oriented fishery was compatible with a trophy-oriented fishery for Muskellunge Esox masquinongy, we modeled effects of a spearing fishery and recreational angling fishery on population size structure (i.e., numbers of fish ≥ 102, 114, and 127 cm) in northern Wisconsin. An individual-based simulation model was used to quantify the effect of harvest mortality at currently observed levels of recreational angling and tribal spearing fishery exploitation, along with simulated increases in exploitation, for three typical growth potentials (i.e., low, moderate, and high) of Muskellunge in northern Wisconsin across a variety of minimum length limits (i.e., 71, 102, 114, and 127 cm). Populations with moderate to high growth potential and minimum length limits ≥ 114 cm were predicted to have lower declines in numbers of trophy Muskellunge when subjected to angling-only and mixed fisheries at observed and increased levels of exploitation, which suggested that fisheries with disparate motivations may be able to coexist under certain conditions such as restrictive length limits and low levels of exploitation. However, for most Muskellunge populations in northern Wisconsin regulated by a 102-cm minimum length limit, both angling and spearing fisheries may reduce numbers of trophy Muskellunge as larger declines were predicted across all growth potentials. Our results may be useful if Muskellunge management options in northern Wisconsin are re-examined in the future.

  2. Spatial orientation and mechanical properties of the human trachea: a computed tomography study.

    PubMed

    Zanella, Alberto; Cressoni, Massimo; Ferlicca, Daniela; Chiurazzi, Chiara; Epp, Myra; Rovati, Cristina; Chiumello, Davide; Pesenti, Antonio; Gattinoni, Luciano; Kolobow, Theodor

    2015-04-01

    The literature generally describes the trachea as oriented toward the right and back, but there is very little detailed characterization. Therefore, the aim of this study was to precisely determine the spatial orientation and to better characterize the physical properties of the human trachea. We analyzed lung computed tomography scans of 68 intubated and mechanically ventilated subjects suffering from acute lung injury/ARDS at airway pressures (Paw) of 5, 15, and 45 cm H2O. At each Paw, the inner edge of the trachea from the subglottal space to the carina was captured. Tracheal length and diameter were measured. Tracheal orientation and compliance were estimated from processing barycenter and surface tracheal sections. Tracheal orientation at a Paw of 5 cm H2O showed a 4.2 ± 5.3° angle toward the right and a 20.6 ± 6.9° angle downward toward the back, which decreased significantly while increasing Paw (19.4 ± 6.9° at 15 cm H2O and 17.1 ± 6.8° at 45 cm H2O, P < .001). Tracheal compliance was 0.0113 ± 0.0131 mL/cm H2O/cm of trachea length from 5 to 15 cm H2O and 0.004 ± 0.0041 mL/cm H2O/cm of trachea length from 15 to 45 cm H2O (P < .001). Tracheal diameter was 19.6 ± 3.4 mm on the medial-lateral axis and 21.0 ± 4.3 mm on the sternal-vertebral axis. The trachea is oriented downward toward the back at a 20.6 ± 6.9° angle and slightly toward the right at a 4.2 ± 5.3° angle. Understanding tracheal orientation may help in enhancing postural drainage and respiratory physiotherapy, and knowing the physical properties of the trachea may aid in endotracheal tube cuff design. Copyright © 2015 by Daedalus Enterprises.

  3. Minimizing Leg Length Discrepancy After Intramedullary Nailing of Comminuted Femoral Shaft Fractures: A Quality Improvement Initiative Using the Scout Computed Tomography Scanogram.

    PubMed

    Gheraibeh, Petra; Vaidya, Rahul; Hudson, Ian; Meehan, Robert; Tonnos, Frederick; Sethi, Anil

    2018-05-01

    To prevent leg length discrepancy (LLD) after locked femoral nailing in patients with comminuted femoral shaft fractures. Prospective consecutive case series aimed at quality improvement. Level 1 Trauma Center PATIENTS:: Ninety-eight consecutive patients with a comminuted femoral shaft fracture underwent statically locked intramedullary nailing, with a focused attempt at minimizing LLD during surgery. A computed tomography scanogram of both legs was performed on postoperative day 1 to assess for residual LLD. Patients were offered the option to have LLD >1.5 cm corrected before discharge. LLD >1.5 cm. Twenty-one patients (21.4%) were found to have an LLD >1.5 cm. An LLD >1.5 cm occurred in 10/55 (18%) antegrade nail patients and 11/43 (26%) retrograde nail patients (P = 0.27). No difference was noted based on the mechanism of injury, surgeon training and OTA/AO type B versus C injury. Ninety of 98 patients left with <1.5 cm LLD, 13/21 had a correction all to ≤0.6 cm, and 8 decided to accept the LLD and declined early correction. No patient left the hospital with an LLD >1.5 cm after locked intramedullary nailing for a comminuted femoral shaft fracture without being informed and the option of early correction. We recommend using a full-length computed tomography scanogram after IM nailing of comminuted femur fractures to prevent iatrogenic LLD. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  4. 50 CFR Appendix D to Part 622 - Specifications for Certified BRDs

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (7.6-cm) piece of 1/2-inch (1.3-cm) aluminum pipe and pressed with a 3/8-inch (0.95-cm) die to form a... must be constructed of either number 60 twine 80 inches (203.2 cm) in length or 3/8-inch (0.95-cm... excluder device (TED) grid; and, (4) the area of the escape opening must total at least 864 in2 (5,574.2...

  5. Oxygen Generating Biomaterials Preserve Skeletal Muscle Homeostasis under Hypoxic and Ischemic Conditions

    DTIC Science & Technology

    2013-08-26

    muscles comprised of predominantly slow oxidative and fast glycolytic fibers [18], [19], [20]. In response to hypoxia (or anoxia), ATP concentrations are...is 1.06 g/cm and the EDL fiber to muscle length ratio is 0.44 [30], [31], [32]. Unless otherwise indicated, active specific forces are reported (peak...during acute hypoxia of resting muscle . Under oxygenated conditions (95% O – 5% CO ), isometric tetanic force as a function of the stimulation

  6. Contemporary Labor Patterns: The Impact of Maternal Body Mass Index

    PubMed Central

    KOMINIAREK, Michelle A.; ZHANG, Jun; VANVELDHUISEN, Paul; TROENDLE, James; BEAVER, Julie; HIBBARD, Judith U.

    2011-01-01

    Objective To compare labor patterns by body mass index (BMI). Study Design 118,978 gravidas with a singleton term cephalic gestation were studied. Repeated-measures analysis constructed average labor curves by parity and BMI categories for those that reached 10cm. Interval censored regression analysis determined median traverse times adjusting for covariates in vaginal deliveries and intrapartum cesareans. Results For nulliparas, the time difference to reach 10 cm was 1.2 hours from the lowest to highest BMI category. Multiparas entered active phase by 6 cm, but reaching this point took longer for BMI≥40.0 (3.4hours) compared to BMI<25.0 (2.4hours). Progression by centimeter (P<0.001) except from 7–9cm in multiparas (P>0.05), and from 4–10cm (P<0.001) increased as BMI increased for nulliparas and multiparas. Second stage length with and without an epidural was similar among BMI categories for nulliparas (P>0.05), but decreased as BMI increased for multiparas (P<0.001). Conclusion Labor proceeds more slowly as BMI increases suggesting that labor management be tailored to allow for these differences. PMID:21798510

  7. Architectural properties of the neuromuscular compartments in selected forearm skeletal muscles

    PubMed Central

    Liu, An-Tang; Liu, Ben-Li; Lu, Li-Xuan; Chen, Gang; Yu, Da-Zhi; Zhu, Lie; Guo, Rong; Dang, Rui-Shan; Jiang, Hua

    2014-01-01

    The purposes f this study were to (i) explore the possibility of splitting the selected forearm muscles into separate compartments in human subjects; (ii) quantify the architectural properties of each neuromuscular compartment; and (iii) discuss the implication of these properties in split tendon transfer procedures. Twenty upper limbs from 10 fresh human cadavers were used in this study. Ten limbs of five cadavers were used for intramuscular nerve study by modified Sihler's staining technique, which confirmed the neuromuscular compartments. The other 10 limbs were included for architectural analysis of neuromuscular compartments. The architectural features of the compartments including muscle weight, muscle length, fiber length, pennation angle, and sarcomere length were determined. Physiological cross-sectional area and fiber length/muscle length ratio were calculated. Five of the selected forearm muscles were ideal candidates for splitting, including flexor carpi ulnaris, flexor carpi radials, extensor carpi radialis brevis, extensor carpi ulnaris and pronator teres. The humeral head of pronator teres contained the longest fiber length (6.23 ± 0.31 cm), and the radial compartment of extensor carpi ulnaris contained the shortest (2.90 ± 0.28 cm). The ulnar compartment of flexor carpi ulnaris had the largest physiological cross-sectional area (5.17 ± 0.59 cm2), and the ulnar head of pronator teres had the smallest (0.67 ± 0.06 cm2). Fiber length/muscle length ratios of the neuromuscular compartments were relatively low (average 0.27 ± 0.09, range 0.18–0.39) except for the ulnar head of pronator teres, which had the highest one (0.72 ± 0.05). Using modified Sihler's technique, this research demonstrated that each compartment of these selected forearm muscles has its own neurovascular supply after being split along its central tendon. Data of the architectural properties of each neuromuscular compartment provide insight into the ‘design’ of their functional capability. In addition to improving our understanding of muscle anatomy and function, elucidation of forearm neuromuscular compartments architecture may ultimately provide information useful for selection of muscle subdivisions used in tendon transfer. PMID:24836406

  8. Cutting efficiency of conventional and martensitic nickel-titanium instruments for coronal flaring.

    PubMed

    Morgental, Renata Dornelles; Vier-Pelisser, Fabiana Vieira; Kopper, Patrícia Maria Poli; de Figueiredo, José Antonio Poli; Peters, Ove A

    2013-12-01

    This study aimed at evaluating the influence of rotational speed and number of uses on the cutting efficiency of 4 nickel-titanium coronal flaring instruments against 2 substrates, bovine dentin and acrylic blocks. BioRaCe BR0, HyFlex CM1, ProFile OS#2, and ProTaper Sx were used in simulated lateral action against both substrates at 250 and 500 rpm up to 5 times, producing 5 notches in each block. Notch areas and lengths were measured under a stereomicroscope, and data were compared by using parametric tests (α = 0.05). Against both substrates, HyFlex CM1 and ProFile OS#2 were the most and the least cutting efficient instruments, respectively (P < .05). Against acrylic, area and length values at 500 rpm were significantly higher than those at 250 rpm for all brands. Against dentin, significant differences were detected between 250 and 500 rpm for HyFlex CM1 and ProTaper Sx (area) and for BioRace BR0, HyFlex CM1, and ProTaper Sx (length). Regarding cutting efficiency loss, area and length for notches 1 and 2 (first notches) and 4 and 5 (last notches) were similar against acrylic. Against dentin, length values for notches 1 and 2 were significantly higher than those for notches 4 and 5 in ProFile OS#2 and ProTaper Sx. A strong correlation was detected between the overall results obtained on acrylic and dentin for area and length (P < .0001), although further analysis showed that data against acrylic were a poor predictor of data against dentin after repeated use. HyFlex CM1 was the most cutting efficient instrument in lateral action. An increase in rotational speed improved the cutting efficiency. Results against acrylic showed a high correlation to data against dentin, but acrylic may not be a proper substrate when the intention is to assess cutting efficiency loss with repeated use. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. Thermal probe design for Europa sample acquisition

    NASA Astrophysics Data System (ADS)

    Horne, Mera F.

    2018-01-01

    The planned lander missions to the surface of Europa will access samples from the subsurface of the ice in a search for signs of life. A small thermal drill (probe) is proposed to meet the sample requirement of the Science Definition Team's (SDT) report for the Europa mission. The probe is 2 cm in diameter and 16 cm in length and is designed to access the subsurface to 10 cm deep and to collect five ice samples of 7 cm3 each, approximately. The energy required to penetrate the top 10 cm of ice in a vacuum is 26 Wh, approximately, and to melt 7 cm3 of ice is 1.2 Wh, approximately. The requirement stated in the SDT report of collecting samples from five different sites can be accommodated with repeated use of the same thermal drill. For smaller sample sizes, a smaller probe of 1.0 cm in diameter with the same length of 16 cm could be utilized that would require approximately 6.4 Wh to penetrate the top 10 cm of ice, and 0.02 Wh to collect 0.1 g of sample. The thermal drill has the advantage of simplicity of design and operations and the ability to penetrate ice over a range of densities and hardness while maintaining sample integrity.

  10. Differences in lateral ankle laxity measured via stress ultrasonography in individuals with chronic ankle instability, ankle sprain copers, and healthy individuals.

    PubMed

    Croy, Theodore; Saliba, Susan A; Saliba, Ethan; Anderson, Mark W; Hertel, Jay

    2012-07-01

    Cross-sectional. To use stress ultrasonography to measure the change in anterior talofibular ligament length during the simulated anterior drawer and ankle inversion stress tests. In approximately 30% of individuals, ankle sprains may eventually develop into chronic ankle instability (CAI) with recurrent symptoms. Individuals with CAI and those who have a history of ankle sprain (greater than 1 year prior) without chronic instability (copers) may or may not have mechanical laxity. Sixty subjects (n=60 ankles) were divided into 3 groups: 1) Control subjects without ankle injury history (n=20; mean ± SD age; 24.8 ± 4.8 years; height, 173.7 ± 9.4 cm; weight, 77.2 ± 19.5 kg), ankle sprain copers (n=20; 22.3 ± 2.9 years; 172.8 ± 11.3 cm; 72.4 ± 14.3 kg), and subjects with CAI (n=20; 23.5 ± 4.2 years; 174.6 ± 9.6 cm; 74.8 ± 17.3 kg). Ligament length change with the anterior drawer and end range ankle inversion was calculated from ultrasound images. The Foot and Ankle Ability Measure (FAAM) was used to quantify self-reported function on activities-of-daily living (ADL) and sports. The anterior drawer test resulted in length changes that were greater (F₂,₅₇=6.2, P=.004) in the CAI (mean ± SD length change, 15.6 ± 15.1%, P=.006) and the coper groups (14.0 ± 15.9%, P=.016) compared to the control group (1.3 ± 10.7%); however the length change for the CAI and coper groups were not different (P=.93). Ankle inversion similarly resulted in greater ligament length change (F₂,₅₇=6.5, P=.003) in the CAI (25.3 ± 15.5%, P=.003) and coper groups (20.2 ± 19.6%, P=.039) compared to the control group (7.4 ± 12.9%); with no difference in length change between the copers and CAI groups (P=.59). The CAI group had a lower score on the FAAM-ADL (87.4 ± 13.4%) and FAAM-Sports (74.2 ± 17.8%) when compared to the control (98.8 ± 2.9% and 98.9 ± 3.1%, P<.0001) and coper groups (99.4 ± 1.8% and 94.6 ± 8.8%, P<.0001). Stress ultrasonography identified greater length changes of the anterior talofibular ligament in both the coper and CAI groups compared to the control group. Only subjects with CAI had reductions in self-reported function.

  11. [Renal length measured by ultrasound in adult mexican population].

    PubMed

    Oyuela-Carrasco, J; Rodríguez-Castellanos, F; Kimura, E; Delgado-Hernández, R; Herrera-Félix, J P

    2009-01-01

    Renal length estimation by ultrasound is an important parameter in clinical evaluation of kidney disease and healthy donors. Changes in renal volume may be a sign of kidney disease. Correct interpretation of renal length requires the knowledge of normal limits, these have not been described for Latin American population. To describe normal renal length (RL) by ultrasonography in a group of Mexican adults. Ultrasound measure of RL in 153 healthy Mexican adults stratified by age. Describe the association of RL to several anthropometric variables. A total of 77 males and 76 females were scanner. The average age for the group was 44.12 +/- 15.44 years. The mean weight, body mass index (BMI) and height were 68.87 +/- 11.69 Kg, 26.77 +/- 3.82 kg/m2 and 160 +/- 8.62 cm respectively. Dividing the population by gender, showed a height of 166 +/- 6.15 cm for males and 154.7 +/- 5.97 cm for females (p =0.000). Left renal length (LRL) in the whole group was 105.8 +/- 7.56 mm and right renal length (RRL) was 104.3 +/- 6.45 mm (p = 0.000.) The LRL for males was 107.16 +/- 6.97 mm and for females was 104.6 +/- 7.96 mm. The average RRL for males was 105.74 +/- 5.74 mm and for females 102.99 +/- 6.85 mm (p = 0.008.) We noted that RL decreased with age and the rate of decline accelerates alter 60 years of age. Both lengths correlated significantly and positively with weight, BMI and height. The RL was significantly larger in males than in females in both kidneys (p = 0.036) in this Mexican population. Renal length declines after 60 years of age and specially after 70 years.

  12. After-hours or weekend rehabilitation improves outcomes and increases physical activity but does not affect length of stay: a systematic review.

    PubMed

    Scrivener, Katharine; Jones, Taryn; Schurr, Karl; Graham, Petra L; Dean, Catherine M

    2015-04-01

    In adults undergoing inpatient rehabilitation, does additional after-hours rehabilitation decrease length of stay and improve functional outcome, activities of daily living performance and physical activity? Systematic review with meta-analysis of randomised trials. Adults participating in an inpatient rehabilitation program. Additional rehabilitation provided after hours (evening or weekend). Function was measured with tests such as the Motor Assessment Scale, 10-m walk test, the Timed Up and Go test, and Berg Balance Scale. Performance on activities of daily living was measured with the Barthel index or the Functional Independence Measure. Length of stay was measured in days. Physical activity levels were measured as number of steps or time spent upright. Standardised mean differences (SMD) or mean differences (MD) were used to combine these outcomes. Adverse events were summarised using relative risks (RR). Study quality was assessed using PEDro scores. Seven trials were included in the review. All trials had strong methodological quality, scoring 8/10 on the PEDro scale. Among the measures of function, only balance showed a significant effect: the MD was 14 points better (95% CI 5 to 23) with additional after-hours rehabilitation on a 0-to-56-point scale. The improvement in activities of daily living performance with additional after-hours rehabilitation was of borderline statistical significance (SMD 0.10, 95% CI 0.00 to 0.21). Hospital length of stay did not differ significantly (MD -1.8 days, 95% CI -5.1 to 1.6). Those receiving additional rehabilitation had significantly higher step counts and spent significantly more time upright. Overall, the risk of adverse events was not increased by the provision of after-hours or weekend rehabilitation (RR 0.87, 95% CI 0.70 to 1.10). Additional after-hours rehabilitation can increase physical activity and may improve activities of daily living, but does not seem to affect the hospital length of stay. PROSPERO CRD42014007648. [Scrivener K, Jones T, Schurr K, Graham PL, Dean CM (2015) After-hours or weekend rehabilitation improves outcomes and increases physical activity but does not affect length of stay: a systematic review.Journal of Physiotherapy61: 61-67]. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  13. Consistent latencies of vestibular evoked myogenic potentials.

    PubMed

    Wang, Shou-Jen; Yeh, Te-Huei; Chang, Chun-Hsiang; Young, Yi-Ho

    2008-12-01

    This study investigated the association between neck length and vestibular evoked myogenic potential (VEMP) latencies in healthy children, adolescents, and adults to elucidate when VEMP latencies reach consistent levels. Findings of VEMP tests in 14 healthy children, seven healthy adolescents, and 14 healthy adults were analyzed for correlations with neck length, which was measured as the distance of a line dropping vertically from the mastoid tip to the horizontal plane passing through the clavicle. All healthy children, adolescents, and adults exhibited present VEMP responses. Children, adolescents, and adults significantly differed in p13 latency, n23 latency, and p13-n23 interval. According to receiver operating characteristic curve analysis, the optimal cutoff values of p13 and n23 latencies between children and adults were 12.6 and 19.8 msec, respectively. Because the odds ratio of p13 latency was less than that of n23 latency, n23 latency was used to discriminate VEMP latencies between children and adults. Accordingly, a cutoff value of 15.3 cm for neck length was proposed as a criterion for predicting VEMP latency within the adult range. Consequently, a positive correlation between neck length and VEMP latency was observed when neck length was <15.3 cm, while above which level one need not account for neck length in evaluating VEMP latency. The intra-subject variability of norms can be enhanced if the normative data for VEMP characteristic parameters take structural variance into account. This study suggests that the adult range of VEMP latencies can be anticipated if neck length is >15.3 cm.

  14. Contemporary labor patterns: the impact of maternal body mass index.

    PubMed

    Kominiarek, Michelle A; Zhang, Jun; Vanveldhuisen, Paul; Troendle, James; Beaver, Julie; Hibbard, Judith U

    2011-09-01

    We sought to compare labor patterns by body mass index (BMI). A total of 118,978 gravidas with a singleton term cephalic gestation were studied. Repeated-measures analysis constructed mean labor curves by parity and BMI categories for those who reached 10 cm. Interval-censored regression analysis determined median traverse times, adjusting for covariates in vaginal deliveries and intrapartum cesareans. In the labor curves, the time difference to reach 10 cm was 1.2 hours from the lowest to highest BMI category for nulliparas. Multiparas entered active phase by 6 cm, but reaching this point took longer for BMI ≥40.0 (3.4 hours) compared to BMI <25.0 (2.4 hours). Progression by centimeter (P < .001 for nulliparas) and from 4-10 cm (P < .001 for nulliparas and multiparas) increased as BMI increased. Second stage length, with and without an epidural, was similar among BMI categories for nulliparas (P > .05) but decreased as BMI increased for multiparas (P < .001). Labor proceeds more slowly as BMI increases, suggesting that labor management be altered to allow longer time for these differences. Copyright © 2011 Mosby, Inc. All rights reserved.

  15. Rational Water and Nitrogen Management Improves Root Growth, Increases Yield and Maintains Water Use Efficiency of Cotton under Mulch Drip Irrigation

    PubMed Central

    Zhang, Hongzhi; Khan, Aziz; Tan, Daniel K. Y.; Luo, Honghai

    2017-01-01

    There is a need to optimize water-nitrogen (N) applications to increase seed cotton yield and water use efficiency (WUE) under a mulch drip irrigation system. This study evaluated the effects of four water regimes [moderate drip irrigation from the third-leaf to the boll-opening stage (W1), deficit drip irrigation from the third-leaf to the flowering stage and sufficient drip irrigation thereafter (W2), pre-sowing and moderate drip irrigation from the third-leaf to the boll-opening stage (W3), pre-sowing and deficit drip irrigation from the third-leaf to the flowering stage and sufficient drip irrigation thereafter (W4)] and N fertilizer at a rate of 520 kg ha-1 in two dressing ratios [7:3 (N1), 2:8 (N2)] on cotton root morpho-physiological attributes, yield, WUE and the relationship between root distribution and dry matter production. Previous investigations have shown a strong correlation between root activity and water consumption in the 40–120 cm soil layer. The W3 and especially W4 treatments significantly increased root length density (RLD), root volume density (RVD), root mass density (RMD), and root activity in the 40–120 cm soil layer. Cotton RLD, RVD, RMD was decreased by 13.1, 13.3, and 20.8%, respectively, in N2 compared with N1 at 70 days after planting (DAP) in the 0–40 cm soil layer. However, root activity in the 40–120 cm soil layer at 140 DAP was 31.6% higher in N2 than that in N1. Total RMD, RLD and root activity in the 40–120 cm soil were significantly and positively correlated with shoot dry weight. RLD and root activity in the 40–120 cm soil layer was highest in the W4N2 treatments. Therefore increased water consumption in the deep soil layers resulted in increased shoot dry weight, seed cotton yield and WUE. Our data can be used to develop a water-N management strategy for optimal cotton yield and high WUE. PMID:28611817

  16. An analysis of travel costs on transport of load and nest building in golden hamster.

    PubMed

    Guerra, Rogerio F.; Ades, Cesar

    2002-03-28

    We investigated the effects of travel costs on transporting nest material and nest-building activity in golden hamsters. Nest-deprived animals were submitted to run alleys 30, 90 and 180 cm long to access a source containing paper strips as nest material (Experiment 1) or were submitted to the same travel costs in 24-h experimental sessions (Experiment 2). We noted that increased travel costs were related to a decreased number of trips to the source, larger amounts (cm(2)) of nest material transported per trip (although total loads also decreased in longer alleys), longer intervals between trips, and increased time spent at the source and in nest building activity. Foraging efficiency (i.e. size of load divided by the time spent at the source) decreased as a function of travel costs, and animals transported their loads in two fundamental ways: in 30-cm alleys, they simply used their mouth to pull the paper strips, but in 90- or 180-cm alleys they transported the loads in their cheek pouches. The animals were faster when returning to the home-cage and their running speed (cm/s) increased as a function of the length of the alley, showing that animals are under different environmental pressures when searching for resources and subsequently running back with the load to the nest. Both male and female subjects were sensitive to travel costs, but males engaged in nest building activity more promptly and exhibited higher mean performances in most measures. We conclude that nest material is a good reinforcer, and our major results are in accordance with the predictions of microeconomic and optimal foraging theories.

  17. Vertical small scale variations of sorption and mineralization of three herbicides in subsurface limestone and sandy aquifer

    NASA Astrophysics Data System (ADS)

    Janniche, G. S.; Mouvet, C.; Albrechtsen, H.-J.

    2011-04-01

    Vertical variation in sorption and mineralization potential of mecoprop (MCPP), isoproturon and acetochlor were investigated at low concentrations (μg-range) at the cm-scale in unsaturated sub-surface limestone samples and saturated sandy aquifer samples from an agricultural catchment in Brévilles, France. From two intact core drills, four heterogenic limestone sections were collected from 4.50 to 26.40 m below surface (mbs) and divided into 12 sub-samples of 8-25 cm length, and one sandy aquifer section from 19.20 to 19.53 m depth divided into 7 sub-samples of 4-5 cm length. In the sandy aquifer section acetochlor and isoproturon sorption increased substantially with depth; in average 78% (acetochlor) and 61% (isoproturon) per 5 cm. Also the number of acetochlor and isoproturon degraders (most-probable-number) was higher in the bottom half of the aquifer section (93-> 16 000/g) than in the upper half (4-71/g). One 50 cm long limestone section with a distinct shift in color showed a clear shift in mineralization, number of degraders and sorption: In the two brown, uppermost samples, up to 31% mecoprop and up to 9% isoproturon was mineralized during 231 days, the numbers of mecoprop and isoproturon degraders were 1300 to > 16 000/g, and the sorption of both isoproturon and acetochlor was more than three times higher, compared to the two deeper, grayish samples just below where mineralization (≤ 4%) and numbers of degraders (1-520/g) were low for all three herbicides. In both unsaturated limestone and sandy aquifer, variations and even distinct shifts in both mineralization, number of specific degraders and sorption were seen within just 4-15 cm of vertical distance. A simple conceptual model of herbicides leaching to groundwater through a 10 m unsaturated limestone was established, and calculations showed that a 30 cm active layer with the measured sorption and mineralization values hardly impacted the fate of the investigated herbicides, whereas a total thickness of layers of 1 m would substantially increase natural attenuation.

  18. Electrospray of 1-Butyl-3-Methylimidazolium Dicyanamide Under Variable Flow Rate Operations

    DTIC Science & Technology

    2014-06-27

    cm length. The capillary needle is stainless steel with a tapered tip of 50 μm inner diameter and 3.5 cm length. Both capillaries are commercially...connected. Figure 8 shows the emission current results of a 50 μm stainless - steel tip over the same IL flow rate range as Fig. 5. The emitter... fuming nitric acid, resulting in an ignition delay time of 47 ms, longer than the desired maximumof 5ms.Numerical predictions byBerg andRovey [18,19

  19. Plasma influence on the dispersion properties of finite-length, corrugated waveguides

    NASA Astrophysics Data System (ADS)

    Shkvarunets, A.; Kobayashi, S.; Weaver, J.; Carmel, Y.; Rodgers, J.; Antonsen, T. M., Jr.; Granatstein, V. L.; Destler, W. W.; Ogura, K.; Minami, K.

    1996-03-01

    We present an experimental study of the electromagnetic properties of transverse magnetic modes in a corrugated-wall cavity filled with a radially inhomogeneous plasma. The shifts of the resonant frequencies of a finite-length, corrugated cavity were measured as a function of the background plasma density and the dispersion diagram was reconstructed up to a peak plasma density of 1012 cm-3. Good agreement with a calculated dispersion diagram is obtained for plasma densities below 5×1011 cm-3.

  20. Site Characterization and Analysis Penetrometer System (SCAPS) Heavy Metal Sensors

    DTIC Science & Technology

    2003-04-01

    gigawatts per square centimeter (GW/cm2). Within the small volume about the focal point, rapid heating, vaporization, and ionization of a small amount of the...2001). Briefly, the light emitted from the fiber in the probe is collimated, turned by a quartz prism, and focused by a short- focal -length quartz 5...are decoupled using the configuration shown in Figure 1. The excitation beam is focused by a 25-cm focal length lens through a 2-inch aluminum mirror

  1. Mapping variability of soil water content and flux across 1-1000 m scales using the Actively Heated Fiber Optic method

    NASA Astrophysics Data System (ADS)

    Sayde, Chadi; Buelga, Javier Benitez; Rodriguez-Sinobas, Leonor; El Khoury, Laureine; English, Marshall; van de Giesen, Nick; Selker, John S.

    2014-09-01

    The Actively Heated Fiber Optic (AHFO) method is shown to be capable of measuring soil water content several times per hour at 0.25 m spacing along cables of multiple kilometers in length. AHFO is based on distributed temperature sensing (DTS) observation of the heating and cooling of a buried fiber-optic cable resulting from an electrical impulse of energy delivered from the steel cable jacket. The results presented were collected from 750 m of cable buried in three 240 m colocated transects at 30, 60, and 90 cm depths in an agricultural field under center pivot irrigation. The calibration curve relating soil water content to the thermal response of the soil to a heat pulse of 10 W m-1 for 1 min duration was developed in the lab. This calibration was found applicable to the 30 and 60 cm depth cables, while the 90 cm depth cable illustrated the challenges presented by soil heterogeneity for this technique. This method was used to map with high resolution the variability of soil water content and fluxes induced by the nonuniformity of water application at the surface.

  2. Design of a variable-focal-length optical system

    NASA Technical Reports Server (NTRS)

    Ricks, D.; Shannon, R. R.

    1984-01-01

    Requirements to place an entire optical system with a variable focal length ranging from 20 to 200 cm within a overall length somewhat less than 100 cm placed severe restrictions on the design of a zoom lens suitable for use on a comet explorer. The requirements of a wavelength range of 0.4 to 1.0 microns produced even greater limitations on the possibilities for a design that included a catadioptric (using mirrors and glass) front and followed by a zooming refractive portion. Capabilities available commercial zoom lenses as well as patents of optical systems are reviewed. Preliminary designs of the refractive optics zoom lens and the catadioptric system are presented and evaluated. Of the two, the latter probably has the best chance of success, so long as the shortest focal lengths are not really needed.

  3. [Pedicle flaps based on the sphenopalatine artery: anatomical and surgical study].

    PubMed

    Gras-Cabrerizo, Juan R; Gras-Albert, Juan R; Monjas-Canovas, Irene; García-Garrigós, Elena; Montserrat-Gili, Joan R; Sánchez del Campo, Francisco; Kolanczak, Katarzyna; Massegur-Solench, Humbert

    2014-01-01

    Local pedicle flaps based on the sphenopalatine artery make it possible to reconstruct large defects of the skull base (SB). From January 2008 to January 2013, 64 lesions with involvement of SB were analysed. These lesions were treated using endoscopic endonasal approach and required a pedicle flap based on the sphenopalatine artery. In addition, measurements and flexibility of the flaps were examined in 4 cadaveric nasal cavities. Surgical group. Sixty-four nasoseptal flaps (NSF) were used, in 4 cases associated with a middle turbinate flap (MTF), and in 1 case supplemented with an inferior turbinate flap (ITF). Five cerebrospinal fluid fistulas (8%) were noted. Among patients with initial lesions, 7% presented an anosmia. Cadaveric group. The length of the NSF varied between 5.2 cm and 7.7 cm and the width ranged from 3 cm to 4.5 cm. The ITF provided an anterior-posterior distance between 4.2 cm and 5 cm, with a width between 1.2 cm and 2.8 cm. The mean length of MTFs varied between 3.5 cm and 4.2 cm, with a width between 1.4 cm and 1.9 cm. The most versatile local flap for the reconstruction of skull base defects is the NSF, and flaps pedicled to the posterolateral nasal artery offer an excellent alternative. Copyright © 2013 Elsevier España, S.L. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  4. Characterization and optimization of the HyperV PLX- α coaxial-gun plasma jet

    NASA Astrophysics Data System (ADS)

    Case, Andrew; Brockington, Sam; Cruz, Edward; Witherspoon, F. Douglas

    2017-10-01

    We present results from characterizing and optimizing performance of the contoured gap coaxial plasma guns under development for the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. Plasma jet diagnostics include fast photodiodes for velocimetry and interferometry for line integrated density. Additionally we present results from spectroscopy, both time resolved high resolution spectroscopy using a novel detector and time integrated survey spectroscopy, for measurements of velocity and temperature as well as impurities. Fast imaging gives plume geometry and time integrated imaging gives overall light emission. Results from a novel long record length camera developed by HyperV will also be presented. Experimental results are compared to the desired target parameters for the plasma jets. The target values for the plasmoid are velocity of 50 km/s, mass of 3.5 mg, and length of 10 cm. The best results so far from the exploration of parameter space for gun operation are: 4 mg at >50 km/s, with a length of 10 cm. Peak axial density 34 cm downstream from the muzzle is 2 ×1016 cm-3. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566.

  5. [Penile augmentation and elongation using autologous dermal-fat strip grafting].

    PubMed

    Yang, Zhe; Li, Yang-qun; Tang, Yong; Chen, Wen; Li, Qiang; Zhou, Chuan-de; Zhao, Mu-xin; Hu, Chun-mei

    2012-05-01

    To investigate the effect of autologous dermal-fat strip grafting in penile augmentation and elongation. From May 2004 to December 2010, 24 patients underwent penile enhancement with free dermal-fat strip grafting. Through suprapubic incision, the superior suspensory ligament and part deep suspensory ligament are cutted off to lengthen the penis. The resulted dead space is filled with the autologous dermal-fat strip (6.0-9.5 cm in length, 1.2-1.5 cm in width and 0.6-0.8 cm in depth) to enhance the penis. Primary healing was achieved in 23 cases. Incisional fat liquefaction happened in one case which healed after dressing change. The penile appearance was satisfactory both at rest or erection. The penile length and circumference increased by 2.5-4.8 cm (average, 3.2 cm) and 1.8-3.0 cm (average, 2.4 cm), respectively. 18 patients were followed up for 3 months to 5 years. All the patients were satisfactory on the cosmetic and functional results. No complication happened. It is safe and effective for penile augmention and elongation with autologous dermal-fat strip grafting and disconnection of penile suspensory ligament.

  6. Do parental heights influence pregnancy length?: a population-based prospective study, HUNT 2

    PubMed Central

    2013-01-01

    Background The objective of this study was to examine the association of maternal and paternal height with pregnancy length, and with the risk of pre- and post-term birth. In addition we aimed to study whether cardiovascular risk factors could explain possible associations. Methods Parents who participated in the Nord-Trøndelag Health Study (HUNT 2; 1995–1997) were linked to offspring data from the Medical Birth Registry of Norway (1997–2005). The main analyses included 3497 women who had delivered 5010 children, and 2005 men who had fathered 2798 pregnancies. All births took place after parental participation in HUNT 2. Linear regression was used to estimate crude and adjusted differences in pregnancy length according to parental heights. Logistic regression was used to estimate crude and adjusted associations of parental heights with the risk of pre- and post-term births. Results We found a gradual increase in pregnancy length by increasing maternal height, and the association was essentially unchanged after adjustment for maternal cardiovascular risk factors, parental age, offspring sex, parity, and socioeconomic measures. When estimated date of delivery was based on ultrasound, the difference between mothers in the lower height quintile (<163 cm cm) and mothers in the upper height quintile (≥ 173 cm) was 4.3 days, and when estimated date of delivery was based on last menstrual period (LMP), the difference was 2.8 days. Shorter women (< 163 cm) had lower risk of post-term births, and when estimated date of delivery was based on ultrasound they also had higher risk of pre-term births. Paternal height was not associated with pregnancy length, or with the risks of pre- and post-term births. Conclusions Women with shorter stature had shorter pregnancy length and lower risk of post-term births than taller women, and when EDD was based on ultrasound, they also had higher risk of preterm births. The effect of maternal height was generally stronger when pregnancy length was based on second trimester ultrasound compared to last menstrual period. The association of maternal height with pregnancy length could not be explained by cardiovascular risk factors. Paternal height was neither associated with pregnancy length nor with the risk of pre- and post-term birth. PMID:23383756

  7. Putting POP-Q to the test: does C - D = cervical length?

    PubMed

    Williams, Kathryn S; Rosen, Lisa; Pilkinton, Marjorie L; Dhariwal, Laura; Winkler, Harvey A

    2018-06-01

    We investigated the correlation between calculated cervical length (CCL) and gross specimen cervical length (GCL) after total vaginal hysterectomy (TVH) at the time of surgery for pelvic organ prolapse (POP). This was a retrospective chart review of patients who had undergone TVH with reconstructive surgery for POP between 2013 and 2015. Patients without an intact specimen or documented cervical length in the pathology report were excluded. CCL was defined as the absolute difference between Pelvic Organ Prolapse Quantification (POP-Q) points C and D. GCL was obtained from the pathology report as the distance from the external to the internal os. The Bland-Altman method was used to assess the accuracy of POP-Q measurements with a priori ranges. Symptom severity was evaluated using the PFDI-20 questionnaire. Analysis of variance was used to model both GCL and CCL as a function of prolapse stage and the leading compartment. The final analysis included 202 subjects. Of the CCL measurements, 56.93% were within ±2 cm of GCL, while 36.14% were within ±1 cm. POP stage was significantly associated with GCL (P < 0.0024). CCL was significantly longer in patients with stage 4 POP (3.57 cm, 95% CI 3.13-4.00) than in those with stage 2 POP (P < 0.0017; mean 2.68 cm, 95% CI 2.45-2.92) and stage 3 POP (P < 0.0300; mean 2.94 cm, 95% CI 2.73-3.15). There were no significant correlations between PFDI scores and CCL or GCL. The agreement between POP-Q CCL (|C - D|) and GCL decreases with increasing POP-Q stage. There was no correlation between POP symptom severity and GCL or CCL. GCL significantly increased with increasing POP stage.

  8. Searching for Last Glacial Deep-Sea Polar Carbonates in the Ross Sea Continental slope and Their Relevance to Chronological Constraints

    NASA Astrophysics Data System (ADS)

    Brambati, A.; Bonaccorsi, R.; Quaia, T.; Busetti, M.

    2003-12-01

    Ice-proximal glacial marine sediments from the Antarctic continental margin retain ice rafting events as proxy record for change in the volume and extension of the Antarctic ice sheet throughout glacial-interglacial cycles. However, the sedimentary sequences from the Ross Sea continental margin remain relatively poorly understood and most research has been focused mainly on continental shelf sequences during the last past decades. We present a data set (i.e., X-ray lithology, Multi Sensor Core Logger physical data, and preservation of biogenic carbonates), obtained from six deep-sea cores (1991-1999 Italian Antarctic Research Programme, PNRA - Summer cruises). Specifically, the cores were collected from a) the central Eastern sector (i.e., Core ANTA95-89C, depth: 2056 m, length: 401 cm and Core ANTA99-c22, depth: 2650 m, length: 851 cm); b) the central Western sector (i.e., Core ANTA99-c23; water depth: 2158 m, length: 548 cm; and ANTA99-c24, water depth: 2750 m, length: 811 cm); and c) the North Western sector (i.e., Core ANTA91-08C, and ANTA91-02C) of the Ross Sea Continental slope. Well-preserved calcareous foraminifers (N. pachyderma, sx) in coarse-grained IRD materials sparsely occur and/or are concentrated in discrete layers (i.e., up to 22 cm-thick) of at least three cores (i.e., Cores ANTA91-08, ANTA91-02, and ANTA95-89C, e.g., at 217-238 cm-depth). Some carbonate layers were deposited during a period of time bracketing Stage3/Stage2. In Core 89C foraminifers are associated to multiple ice rafting episodes and likely occurred with oceanographic changes in the properties of slope water masses. The search of well-preserved, in situ-deposited, polar carbonates is demanded for a reliable C-14 AMS dating of late Pleistocene events in the Ross Sea.

  9. Yields and Nutritional of Greenhouse Tomato in Response to Different Soil Aeration Volume at two depths of Subsurface drip irrigation

    PubMed Central

    Li, Yuan; Niu, Wenquan; Dyck, Miles; Wang, Jingwei; Zou, Xiaoyang

    2016-01-01

    This study investigated the effects of 4 aeration levels (varied by injection of air to the soil through subsurface irrigation lines) at two subsurface irrigation line depths (15 and 40 cm) on plant growth, yield and nutritional quality of greenhouse tomato. In all experiments, fruit number, width and length, yield, vitamin C, lycopene and sugar/acid ratio of tomato markedly increased in response to the aeration treatments. Vitamin C, lycopene, and sugar/acid ratio increased by 41%, 2%, and 43%, respectively, in the 1.5 times standard aeration volume compared with the no-aeration treatment. An interaction between aeration level and depth of irrigation line was also observed with yield, fruit number, fruit length, vitamin C and sugar/acid ratio of greenhouse tomato increasing at each aeration level when irrigation lines were placed at 40 cm depth. However, when the irrigation lines were 15 cm deep, the trend of total fruit yields, fruit width, fruit length and sugar/acid ratio first increased and then decreased with increasing aeration level. Total soluble solids and titrable acid decreased with increasing aeration level both at 15 and 40 cm irrigation line placement. When all of the quality factors, yields and economic benefit are considered together, the combination of 40 cm line depth and “standard” aeration level was the optimum combination. PMID:27995970

  10. Conservation status of an endangered annual fish Hypsolebias antenori (Rivulidae) from Northeastern Brazil.

    PubMed

    Nascimento, W S; Yamamoto, M E; Chellappa, N T; Rocha, O; Chellappa, S

    2015-05-01

    This work presents information regarding the biology and state of conservation of an endangered annual fish Hypsolebias antenori. Fish were captured from small seasonal pools located in Northeastern Brazil. The total body length, body mass, sex ratio, first sexual maturity were investigated. The sampled population showed sexual dimorphism. There was a predominance of females (60%) over males (40%) with a sex ratio of 1: 1.4 and males were bigger and heavier than the females. Amplitude of total length of males ranged from 2.6 to 7.1cm (4.1 ± 1.15) and that of females from 2.2 to 5.4 cm (3.6 ± 0.9). Amplitude of body mass of males varied from 0.25 to 7 g (1.3 g ± 1.4) and that of females from 0.12 to 2.1g (0.7 g ± 0.5). The total weight-length equation of males was Wt = 0.0108Lt3.172 with r = 0.9826 and of females was Wt = 0.0122Lt3.0114 with r = 0.9608. Females attained first sexual maturity at 3.2 cm (± 0.25) total length and males at 3.3 cm (± 0.08) total length. All temporary pools surveyed in Northeastern Brazil were in a high degree of degradation, suffering due to anthropogenic action. Reduced rainfall resulting from global climate change prevents the filling up of these pools, thus preventing the completion of the reproductive cycle of annual fishes. One factor hindering development of conservation strategies is limited literature on biology and conservation status of annual fishes. There is a need for conservation measures to protect annual fish populations, especially creation of protected areas in the Brazilian semiarid region.

  11. Importance of colonic support for energy absorption as small-bowel failure proceeds.

    PubMed

    Nordgaard, I; Hansen, B S; Mortensen, P B

    1996-08-01

    Digestive processes in the human colon are affected by the bacterial fermentation of malabsorbed carbohydrates and protein to short-chain fatty acids, which are absorbed and supply energy. Energy absorption was measured by assessing fecal bomb calorimetry in 148 patients with extremely different small-bowel lengths. Colectomy increased fecal loss of energy by 0.8 MJ/d and carbohydrate excretion fivefold in patients with a small-bowel length between normal and 150-200 cm. Patients with 100-150 cm small bowel, with and without a colon, excreted 1.3 +/- 0.3 and 4.7 +/- 0.5 MJ/d, respectively (P = 0.002), a difference of 3.4 MJ/d. Patients with < 100 cm small bowel excreted 3.1 +/- 0.4 and 8.0 +/- 1.3 MJ/d, respectively (P = 0.03), a difference of 4.9 MJ/d. Similar and highly significant differences were calculated by linear-regression analysis. Considerably less energy was excreted as carbohydrate than as fat in patients with preserved colonic function, probably because fermentation removed carbohydrate as absorbed short-chain fatty acids, whereas a comparable amount of energy was lost as carbohydrate and fat in patients without colonic function. The correlation between malabsorbed energy and small-bowel length was poor (r = -0.41) but increased when data for patients with and without a colon were separated (r = -0.56 and r = -0.58, respectively). Small-bowel length, however, was still an inaccurate measure of intestinal failure to absorb nutrient energy. In conclusion, colonic digestion may support energy supply with up to approximately 4.2 MJ/d as small-bowel failure proceeds, but it is of minor importance in patients with a small-bowel length > 200 cm or malabsorption < 2.1 MJ/d.

  12. The GLC8 - A miniature low cost ring laser gyroscope

    NASA Astrophysics Data System (ADS)

    Godart, D.-F.; Peghaire, J.-P.

    SAGEM is enlarging its family of ring laser gyros (RLG) which already includes a triangular 32-cm path-length gyro and a square 16-cm path-length gyro, in order to meet the increasing demand for low cost, medium accuracy strap-down inertial measurement units for applications such as short- and medium-range tactical missiles as well as aided navigation systems for aircrafts and land vehicles. Based on the experience acquired in the past 13 years in the RLG field, and especially in mirror manufacturing, SAGEM developed the GLC8 which has a square 8-cm path length cavity, central piezoelectric dither. It incorporates two cathodes, a single anode, and is technologically designed to minimize production-costs while optimizing the performance to global device size ratio. This gyro is characterized by a bias and a scale-factor stability respectively better than 0.5 deg/h and 100 ppm (1 sigma), and has an operating lifetime compatible with the most demanding relevant applications and a high robustness to mechanical environments.

  13. Effects of wind velocity and slope on fire behavior

    Treesearch

    D.R. Weise; G.S. Biging

    1994-01-01

    Effects of wind velocity and slope on fire spread rate and flame length were examined. Fuel beds of vertical sticks (13.97 cm x 0.455 cm x 0.1 10 cm) and coarse excelsior were burned in an open-topped tilting wind tunnel. Mean fuel moisture content of sticks and excelsior was 11% and 12%, respectively. Mean surface area to volume ratio was 23 cm-! Five slopes (negative...

  14. Across-Gimbal and Miniaturized Cryogenic Loop Heat Pipes

    NASA Astrophysics Data System (ADS)

    Bugby, D.; Marland, B.; Stouffer, C.; Kroliczek, E.

    2003-01-01

    This paper describes the development status of three advanced cryogenic loop heat pipes (CLHP) for solving important problems in cryogenic integration. The three devices described herein are: (1) an across-gimbal CLHP; (2) a short transport length miniaturized CLHP; and (3) a long transport length miniaturized CLHP. The across-gimbal CLHP, which is baselined for operation from 80-100 K with nitrogen, provides a low weight, low torque, high conductance solution for gimbaled cryogenic systems wishing to mount their cryocoolers off-gimbal. The short transport length miniaturized CLHP, which is baselined for operation near 35 K with neon, combines localized thermal transport, flexibility, and thermal switching into one device that can be directly mounted to a cryocooler cold head and a cryogenic component just a short distance (10-20 cm) away. The long transport length miniaturized CLHP, which is also baselined for operation near 35 K with neon, adds to the capabilities of the short transport length miniaturized CLHP by increasing the transport length to over 250 cm to meet cryogenic heat transport device requirements of future NASA and DoD spacecraft.

  15. Dual-layer electrode-driven liquid crystal lens with electrically tunable focal length and focal plane

    NASA Astrophysics Data System (ADS)

    Zhang, Y. A.; Lin, C. F.; Lin, J. P.; Zeng, X. Y.; Yan, Q.; Zhou, X. T.; Guo, T. L.

    2018-04-01

    Electric-field-driven liquid crystal (ELC) lens with tunable focal length and their depth of field has been extensively applied in 3D display and imaging systems. In this work, a dual-layer electrode-driven liquid crystal (DELC) lens with electrically tunable focal length and controllable focal plane is demonstrated. ITO-SiO2-AZO electrodes with the dual-layer staggered structure on the top substrate are used as driven electrodes within a LC cell, which permits the establishment of an alternative controllability. The focal length of the DELC lens can be adjusted from 1.41 cm to 0.29 cm when the operating voltage changes from 15 V to 40 V. Furthermore, the focal plane of the DELC lens can selectively move by changing the driving method of the applied voltage to the next driven electrodes. This work demonstrates that the DELC lens has potential applications in imaging systems because of electrically tunable focal length and controllable focal plane.

  16. A meta-analysis of the effect of hospital-based case management on hospital length-of-stay and readmission.

    PubMed

    Kim, Young-Ju; Soeken, Karen L

    2005-01-01

    Although many hospital-based case management (CM) interventions have been studied, there is little work summarizing the effectiveness of these studies. The purpose of this study was to investigate the effect of hospital-based CM compared with usual care on length of hospital stay and readmission rate. A meta-analytic method was employed to analyze the effect sizes of CM intervention on outcomes. Eligible studies were retrieved using computerized database searches, footnote chasing, and contact with content experts. The authors reviewed the final 12 studies, and the effect size, 95% confidence interval (CI), sensitivity, homogeneity, and publication bias were analyzed. The overall average weighted effect size on length of stay (LOS) was 0.094 with a 95% CI of -0.032 to 0.220. The overall odds ratio for readmission was 0.87 with a 95% CI of 0.69 to 1.04. Overall, hospital-based CM interventions were not significantly effective in reducing LOS and readmissions. However, CM for patients with heart failure (effect size of 0.241 with a 95% CI of 0.012 to 0.470) was significantly effective in reducing LOS, although it was not effective for stroke patients (effect size of -0.226 with a 95% CI of -0.542 to 0.089) and frail elders (effect size of 0.126 with a 95% CI of -0.073 to 0.324). Analysis indicated that in this meta-analysis publication bias was unlikely. The findings of this meta-analysis demonstrate a 6% decrease in readmission rate for patients who received hospital-based CM interventions. Further meta-analytic studies are needed to investigate the effectiveness of CM on other outcomes.

  17. Contamination levels of mercury in the muscle of female and male spiny dogfishes (Squalus acanthias) caught off the coast of Japan.

    PubMed

    Endo, Tetsuya; Hisamichi, Yohsuke; Kimura, Osamu; Kotaki, Yuichi; Kato, Yoshihisa; Ohta, Chiho; Koga, Nobuyuki; Haraguchi, Koichi

    2009-11-01

    We analyzed the total mercury (T-Hg) and stable isotopes of (13)C and (15)N in the muscle of spiny dogfish (Squalus acanthias) caught off the coast of Japan. The average body length of the female spiny dogfish sampled (94.9+/-20.2 cm, 50.5-131.0 cm, n=40) was significantly larger than that of the males sampled (77.8+/-10.8 cm, 55.5-94.0 cm, n=35), although the ages of the samples were unknown. The T-Hg concentration in the muscle samples rapidly increased after maturity in the females (larger than about 120 cm) and males (larger than about 90 cm), followed by a continued gradual increase. Contamination level of T-Hg in female muscle samples (0.387+/-0.378 microg(wet g)(-1), n=40) was slightly higher than that in male muscle samples (0.316+/-0.202 microg(wet g)(-1), n=35), probably due to the greater longevity of females. In contrast, the contamination level of T-Hg in females smaller than 94.0 cm in length (0.204+/-0.098 microg(wet g)(-1), n=20) was slightly lower than that in the males, probably due to the faster growth rate of females. Although the partial differential(13)C and partial differential(15)N values in the muscle samples increased with an increase in body length, there were no significant differences between the females (-17.2+/-0.4 per thousand and 12.4+/-0.9 per thousand, respectively) and males (-17.3+/-0.4 per thousand and 12.4+/-0.8 per thousand, respectively). A positive correlation was found between partial differential(13)C and partial differential(15)N values, suggesting trophic enrichment due to the growth.

  18. Influence of position and length of uterus on implantation and clinical pregnancy rates in IVF and embryo transfer treatment cycles.

    PubMed

    Egbase, P E; Al-Sharhan, M; Grudzinskas, J G

    2000-09-01

    In a prospective study of 807 consecutive women shown to have an apparently normal uterus after hysterosalpingography, hysteroscopy or pelvic ultrasonography prior to IVF or intracytoplasmic sperm injection (ICSI) and embryo transfer, the position and length of the uterine cavity was measured routinely at a pre-treatment mock transfer procedure. The apparent length of the uterine cavity was <7 cm in 128 women (group 1), 7-9 cm in 594 women (group 2) and >9 cm in 85 women (group 3). The uterus was noted to be retroverted in 38. 2% (308) women. The embryo transfer catheter was advanced to 5 mm from the uterine fundus based on the previously determined cavity length in all the embryo transfer procedures at 48 h after oocyte collection. Implantation and clinical pregnancy rates were not significantly different with respect to position of the uterus, difficulties encountered in passage of the catheter, mean age of the women, aetiology or duration of infertility or embryology events. An apparently greater cavity length was seen in older and/or parous women, but the difference was not statistically significant. Although the highest implantation and clinical pregnancy rates were seen in women with a cavity length of 7-9 cm (group 2) the differences were not statistically significant: group 1, 18.9 and 36. 7%; group 2, 21.0 and 46.5%; and group 3, 17.3 and 32.9% respectively. The incidence of ectopic pregnancy per reported clinical pregnancy was highest in group 1 women, being 14.9% (7/47) in comparison with group 2 (1.8%, 5/276) and group 3 (0%, 0/27) (P: < 0.0005), suggesting that the size of the uterus is a critical factor in the aetiology of ectopic pregnancy in IVF/ICSI-embryo transfer.

  19. Pylorus preserving loop duodeno-enterostomy with sleeve gastrectomy - preliminary results

    PubMed Central

    2014-01-01

    Background Bariatric operations mostly combine a restrictive gastric component with a rerouting of the intestinal passage. The pylorus can thereby be alternatively preserved or excluded. With the aim of performing a “pylorus-preserving gastric bypass”, we present early results of a proximal postpyloric loop duodeno-jejunostomy associated with a sleeve gastrectomy (LSG) compared to results of a parallel, but distal LSG with a loop duodeno-ileostomy as a two-step procedure. Methods 16 patients underwent either a two-step LSG with a distal loop duodeno-ileostomy (DIOS) as revisional bariatric surgery or a combined single step operation with a proximal duodeno-jejunostomy (DJOS). Total small intestinal length was determined to account for inter-individual differences. Results Mean operative time for the second-step of the DIOS operation was 121 min and 147 min for the combined DJOS operation. The overall intestinal length was 750.8 cm (range 600-900 cm) with a bypassed limb length of 235.7 cm in DJOS patients. The mean length of the common channel in DIOS patients measured 245.6 cm. Overall excess weight loss (%EWL) of the two-step DIOS procedure came to 38.31% and 49.60%, DJOS patients experienced an %EWL of 19.75% and 46.53% at 1 and 6 months, resp. No complication related to the duodeno-enterostomy occurred. Conclusions Loop duodeno-enterosomies with sleeve gastrectomy can be safely performed and may open new alternatives in bariatric surgery with the possibility for inter-individual adaptation. PMID:24725654

  20. Discovery of Nascent Vents and Recent Colonization Associated with(Re)activated Hydrothermal Vent Fields by the GALREX 2011 Expedition on the Galápagos Rift

    NASA Astrophysics Data System (ADS)

    Shank, T. M.; Holden, J. F.; Herrera, S.; Munro, C.; Muric, T.; Lin, J.; Stuart, L.

    2011-12-01

    GALREX 2011 was a NOAA OER telepresence cruise that explored the diverse habitats and geologic settings of the deep Galápagos region. The expedition made12 Little Hercules ROV dives in July 2011.Abundant corals and a strong depth zonation of species (including deepwater coral communities) were found near 500 m depth on Paramount Seamount, likely influenced by past low sea level states, wave-cut terrace processes, and the historical presence of shallow reef structures. At fresh lava flows with associated (flocculent) hydrothermal venting near 88° W, now known as Uka Pacha and Pegasus Vent Fields, rocks were coated with white microbial mat and lacked sessile fauna, with few mobile fauna (e.g., bythograeid crabs, alvinocarid shrimp, polynoid worms, zoarcid fish, and dirivultid copepods). This suggests a recent creation of hydrothermal habitats through volcanic eruptions and/or diking events, which may have taken place over a 15 km span separating the two vent fields. The Rosebud vent field at 86°W was not observed and may have been covered with lava since last visited in 2005. A hydrothermal vent field near 86°W was discovered that is one of the largest vent fields known on the Rift (120m by 40m). Low-temperature vent habitats were colonized by low numbers of tubeworms including Riftia, Oasisia, and a potential Tevnia species (the latter not previously observed on the Galapagos Rift). Patches of tubeworms were observed with individuals less than 2cm in length, and the relatively few large Riftia had tube lengths near 70cm long. Large numbers of small (< 3cm long) bathymodiolin mussels lined cracks and crevices throughout the active part of the field. Live clams, at least four species of gastropod limpets, three species of polynoid polychaetes, juvenile and adult alvinocarid shrimp, actinostolid anemones, and white microbial communities were observed on the underside and vertical surfaces of basalt rock surfaces. There were at least 13 species of vent-endemic fauna. The active colonization was observed on relatively older basalt pillows and lobate lavas ringed by and amidst a large dead bed of Calyptogena clams (most with broken and dissolving shells greater than 25 cm in length, with a few of the same size living amongst the dissolving shells). Scattered pockets of living adult mussels were observed among these dead clams. The margins of the field were ringed with large numbers of dandelion siphonophores. This field, named Tempus Fugit Vent Field, was once a massive clam bed (> 20 years old) and now, while hosting mature mussel communities and adult clams (> 2 years old), is being actively colonized by vent-endemic fauna that can be considered to be recent arrivals and colonizers (less than a few months) at Galapagos vent fields. These findings not only provide strong evidence of recent volcanic activity between 85° W and 88° W on the Galapagos Rift, but provide evidence that the rates of hydrothermal habitat turnover via eruption, dike injection, or venting cessation may be considerably higher than previously thought along the Galápagos Rift.

  1. 50 CFR 622.436 - Size limits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... intact. (a) Yellowtail snapper. The minimum size limit for yellowtail snapper is 12 inches (30.5 cm), TL... inches (20.3 cm), fork length. [78 FR 22952, Apr. 17, 2013, as amended at 78 FR 45896, July 30, 2013] ...

  2. 50 CFR 622.436 - Size limits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... intact. (a) Yellowtail snapper. The minimum size limit for yellowtail snapper is 12 inches (30.5 cm), TL... inches (20.3 cm), fork length. [78 FR 22952, Apr. 17, 2013, as amended at 78 FR 45896, July 30, 2013] ...

  3. Granularity in the magnetic field structure of M83

    NASA Technical Reports Server (NTRS)

    Allen, R. J.; Sukumar, S.

    1990-01-01

    Researchers recently reported Very Large Array (VLA) 20 cm continuum polarization observations of the bright, nearly face-on southern spiral galaxy M83 (NGC 5236) at a spatial resolution of 2 kpc (Sukumar and Allen 1989). The strongest linearly-polarized emission is found in two giant arcs, with typical lengths of about 30 kpc, which are situated roughly opposite each other in the dark outer regions of the galaxy at a radius of 12 kpc from the center. These regions of high polarized intensity (and hence highly-uniform magnetic field) do not coincide with any prominent spiral-arm tracers, in contrast to the expectations of simple models for the large-scale compression of magnetic field in density-wave shock fronts. From a comparison of the data with previous results at 6 cm, the authors concluded that the low polarization in the central regions of the galaxy is a result of disorder in the interstellar magnetic field. The most likely cause of this disorder is the greater star formation activity observed in the inner parts of the galaxy. The intrinsic direction of the magnetic field in the outer parts of the galaxy has also recently been determined on a length scale of 6.5 kpc from a comparison of the VLA 20 cm results with 6.3 cm observations obtained earlier with the Effelsberg telescope (Sukumar et al. 1989). There is very little Faraday rotation in the regions of the highly-polarized arcs of emission. The magnetic field in these polarized arcs is parallel to the general spiral arm structure seen in the usual optical tracers (dust, HII regions) in the bright inner parts of the galaxy disk. The maximum observed polarization at 2 kpc resolution is about 50 percent.

  4. Hamstring injury prevention in soccer: Before or after training?

    PubMed

    Lovell, R; Knox, M; Weston, M; Siegler, J C; Brennan, S; Marshall, P W M

    2018-02-01

    We examined the effects of a 12-week program of Nordic hamstring exercises (NHE), administered before or after football training, upon eccentric hamstring strength, muscle activity, and architectural adaptations. Amateur soccer players were randomized into three groups. The control group (CON; n=11) undertook core stability exercises, whereas a periodized NHE program was delivered either before (NHE BEF ; n=10) or after (NHE AFT ; n=14) biweekly training sessions. Outcome measures included peak torque and concomitant normalized peak surface electromyography signals (sEMG) of the biceps femoris (BF) and medial hamstring (MH) muscles during knee flexor maximal eccentric contractions, performed at 30°·s -1 . Ultrasonography was used to determine BF muscle thickness, muscle fiber pennation angle, and fascicle length. Performing the NHE derived likely moderate peak torque increases in both NHE BEF (+11.9%; 90% confidence interval: 3.6%-20.9%) and NHE AFT (+11.6%; 2.6%-21.5%) vs CON. Maximum sEMG increases were moderately greater in the BF of both NHE training groups vs CON. There were likely moderate increases in BF muscle thickness (+0.17 cm; 0.05-0.29 cm) and likely small pennation angle increases (+1.03°; -0.08° to 2.14°) in NHE AFT vs CON and NHE BEF . BF fascicle length increases were likely greater in NHE BEF (+1.58 cm; 0.48-2.68 cm; small effect) vs CON and NHE AFT . A 12-week eccentric hamstring strengthening program increased strength and sEMG to a similar magnitude irrespective of its scheduling relative to the football training session. However, architectural adaptations to support the strength gains differed according to the timing of the injury prevention program. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Is increased residual shank length a competitive advantage for elite transtibial amputee long jumpers?

    PubMed

    Nolan, Lee; Patritti, Benjamin L; Stana, Laura; Tweedy, Sean M

    2011-07-01

    The purpose of this study was to evaluate the extent to which residual shank length affects long jump performance of elite athletes with a unilateral transtibial amputation. Sixteen elite, male, long jumpers with a transtibial amputation were videoed while competing in major championships (World Championships 1998, 2002 and Paralympic Games, 2004). The approach, take-off, and landing of each athlete's best jump was digitized to determine residual and intact shank lengths, jump distance, and horizontal and vertical velocity of center of mass at touchdown. Residual shank length ranged from 15 cm to 38 cm. There were weak, nonsignificant relationships between residual shank length and (a) distance jumped (r = 0.30), (b) horizontal velocity (r = 0.31), and vertical velocity (r = 0.05). Based on these results, residual shank length is not an important determinant of long jump performance, and it is therefore appropriate that all long jumpers with transtibial amputation compete in the same class. The relationship between residual shank length and key performance variables was stronger among athletes that jumped off their prosthetic leg (N = 5), and although this result must be interpreted cautiously, it indicates the need for further research.

  6. Responses to two-way selection on growth in mass-spawned F1 progeny of Argopecten irradians concentricus (Say)

    NASA Astrophysics Data System (ADS)

    Wang, Hui; Liu, Jin; Li, Yanhong; Zhu, Xiaowen; Liu, Zhigang

    2014-03-01

    In the present study, the effect of one-generation divergent selection on the growth and survival of the bay scallop ( Argopecten irradians concentricus) was examined to evaluate the efficacy of a selection program currently being carried out in Beibu Bay in the South China Sea. A total of 146 adult scallops were randomly selected from the same cultured population of A. i. concentricus, and divided into two groups in shell length (anterior-posterior measurement): large (4.91-6.02 cm, n=74) and small (3.31-4.18 cm, n=72). At the same time, a control group was also randomly sampled (4.21-4.88 cm, n =80). Mass-spawned F 1 progenies from the three size groups were obtained and reared under identical conditions at all growth phases. The effects of two-way (or upward-downward) selection on fertilization rate, hatching rate, survival rate, daily growth in shell length and body weight were assessed in the three size groups. Results show that significant differences ( P<0.01) were found in hatching rate, survival rate and daily growth of F1 progenies, but not in fertilization rate ( P>0.05), among the three groups. The hatching rate, survival rate and daily growth of the progeny of large-sized parents were greater than those of the control group ( P<0.05), which in turn were larger than those of small-sized group ( P<0.05). Responses to selection by shell length and body weight were 0.32 ± 0.04 cm and 2.18 ± 0.05 g, respectively, for the upward selection, and -0.14 ± 0.03 cm and -2.77 ± 0.06 g, respectively, for the downward selection. The realized heritability estimates of shell length and body weight were 0.38 ± 0.06 cm and 0.22 ± 0.07 g for the upward selection, and 0.24 ± 0.06 cm and 0.37 ± 0.09 g for the downward selection, respectively. The change in growth by bidirectional selection suggests that high genetic variation may be present in the cultured bay scallop population in China.

  7. Comparative Analyses of Cuticular Waxes on Various Organs of Potato (Solanum tuberosum L.).

    PubMed

    Guo, Yanjun; Jetter, Reinhard

    2017-05-17

    Complex mixtures of cuticular waxes coat plant surfaces to seal them against environmental stresses, with compositions greatly varying between species and possibly organs. This paper reports comprehensive analyses of the waxes on both above- and below-ground organs of potato, where total wax coverages varied between petals (2.6 μg/cm 2 ), leaves, stems, and tubers (1.8-1.9 μg/cm 2 ), and rhizomes (1.1 μg/cm 2 ). The wax mixtures on above-ground organs were dominated by alkanes, occurring in homologous series of isomeric C 25 -C 35 n-alkanes, C 25 -C 35 2-methylalkanes, and C 26 -C 34 3-methylalkanes. In contrast, below-ground organs had waxes rich in monoacylglycerols (C 22 -C 28 acyls) and C 18 -C 30 alkyl ferulates, together with fatty acids (rhizomes) or primary alcohols (tubers). The organ-specific wax coverages, compound class distribution, and chain length profiles suggest highly regulated activities of wax biosynthesis enzymes, likely related to organ-specific ecophysiological functions.

  8. Ultra-low specific contact resistivity (1.4 × 10-9 Ω.cm2) for metal contacts on in-situ Ga-doped Ge0.95Sn0.05 film

    NASA Astrophysics Data System (ADS)

    Wu, Ying; Luo, Sheng; Wang, Wei; Masudy-Panah, Saeid; Lei, Dian; Liang, Gengchiau; Gong, Xiao; Yeo, Yee-Chia

    2017-12-01

    A heavily Ga-doped Ge0.95Sn0.05 layer was grown on the Ge (100) substrate by molecular beam epitaxy (MBE), achieving an active doping concentration of 1.6 × 1020 cm-3 without the use of ion implantation and high temperature annealing that could cause Sn precipitation or surface segregation. An advanced nano-scale transfer length method was used to extract the specific contact resistivity ρc between the metal and the heavily doped p-Ge0.95Sn0.05 layer. By incorporating Sn into Ge and in-situ Ga doping during the MBE growth, an ultra-low ρc of 1.4 × 10-9 Ω.cm2 was achieved, which is 50% lower than the ρc of p+-Ge control and is also the lowest value obtained for metal/p-type semiconductor contacts.

  9. The effect of stochastic modeling of ionospheric effect on the various lengths of baseline determination

    NASA Astrophysics Data System (ADS)

    Kwon, J.; Yang, H.

    2006-12-01

    Although GPS provides continuous and accurate position information, there are still some rooms for improvement of its positional accuracy, especially in the medium and long range baseline determination. In general, in case of more than 50 km baseline length, the effect of ionospheric delay is the one causing the largest degradation in positional accuracy. For example, the ionospheric delay in terms of double differenced mode easily reaches 10 cm with baseline length of 101 km. Therefore, many researchers have been tried to mitigate/reduce the effect using various modeling methods. In this paper, the optimal stochastic modeling of the ionospheric delay in terms of baseline length is presented. The data processing has been performed by constructing a Kalman filter with states of positions, ambiguities, and the ionospheric delays in the double differenced mode. Considering the long baseline length, both double differenced GPS phase and code observations are used as observables and LAMBDA has been applied to fix the ambiguities. Here, the ionospheric delay is stochastically modeled by well-known Gaussian, 1st and 3rd order Gauss-Markov process. The parameters required in those models such as correlation distance and time is determined by the least-square adjustment using ionosphere-only observables. Mainly the results and analysis from this study show the effect of stochastic models of the ionospheric delay in terms of the baseline length, models, and parameters used. In the above example with 101 km baseline length, it was found that the positional accuracy with appropriate ionospheric modeling (Gaussian) was about ±2 cm whereas it reaches about ±15 cm with no stochastic modeling. It is expected that the approach in this study contributes to improve positional accuracy, especially in medium and long range baseline determination.

  10. Progress in second-generation HTS wire development and manufacturing

    NASA Astrophysics Data System (ADS)

    Selvamanickam, V.; Chen, Y.; Xiong, X.; Xie, Y.; Zhang, X.; Rar, A.; Martchevskii, M.; Schmidt, R.; Lenseth, K.; Herrin, J.

    2008-09-01

    2007 has marked yet another year of continued rapid progress in developing and manufacturing high-performance, long-length second-generation (2G) HTS wires at high speeds. Using ion beam assisted deposition (IBAD) MgO and associated buffer sputtering processes, SuperPower has now exceeded piece lengths of 1000 m of fully buffered tape reproducibly with excellent in-plane texture of 6-7 degrees and uniformity of about 2%. These kilometer lengths are produced at high speeds of about 350 m/h of 4 mm wide tape. In combination with metal organic chemical vapor deposition (MOCVD), 2G wires up to single piece lengths to 790 m with a minimum critical current value of 190 A/cm corresponding to a Critical current × Length performance of 150,100 Am have been achieved. Tape speeds up to 180 m/h have been reached MOCVD while maintaining critical currents above 200 A/cm in 100+ m lengths. Thick film MOCVD technology has been transitioned to Pilot manufacturing system where a minimum critical current of 320 A/cm has been demonstrated over a length of 155 m processed at a speed of 70 m/h in 4 mm width. Finally, nearly 10,000 m of 2G wire has been produced, exhaustively tested, and delivered to the Albany Cable project. The average minimum critical current of the wire delivered in 225 segments of 43-44 m is 70 A in 4 mm widths. A 30 m cable has been fabricated with this wire by Sumitomo Electric and has been installed in the power grid of National Grid in downtown Albany and is the world’s first 2G device installed in the grid.

  11. Spatial ecology of coastal Atlantic cod Gadus morhua associated with parasite load.

    PubMed

    Aalvik, I M; Moland, E; Olsen, E M; Stenseth, N C

    2015-08-01

    Acoustic tags and receivers were used to investigate the spatial ecology of coastal Atlantic cod Gadus morhua (n = 32, mean fork length: 50 cm, range: 33-80 cm) on the Norwegian Skagerrak coast in 2012. Monthly home ranges (HR), swimming activity and depth use varied considerably among individuals and through the months of June, July and August. HR sizes for the period ranged from 0.25 to 5.20 km2 (mean = 2.30 km2. Two thirds of the tagged G. morhua were infected with black spot disease Cryptocotyle lingua parasites; these fish had larger HRs and occupied deeper water compared with non-infected fish. The infected fish also tended to be more active in terms of horizontal swimming. From an ecological and evolutionary perspective, any environmental change that modifies G. morhua behaviour may therefore also alter the parasite load of the population, and its conservation and fishery status. © 2015 The Fisheries Society of the British Isles.

  12. Wing shielding of high velocity jet and shock-associated noise with cold and hot flow jets

    NASA Technical Reports Server (NTRS)

    Vonglahn, U.; Groesbeck, D.; Wagner, J.

    1976-01-01

    Jet exhaust noise shielding data are presented for cold and hot flows (ambient to 1,100 K) and pressure ratios from 1.7 to 2.75. A nominal 9.5-cm diameter conical nozzle was used with simple shielding surfaces that were varied in length from 28.8 to 114.3 cm. The nozzle was located 8.8 cm above the surfaces. The acoustic data with the various sheilding lengths are compared to each other and to that for the nozzle alone. In general, short shielding surfaces that provided shielding for subsonic jets did not provide as much shielding for jets with shock noise, however, long shielding surfaces did shield shock noise effectively.

  13. Sensitive detection of methane at 3.3 μm using an integrating sphere and interband cascade laser

    NASA Astrophysics Data System (ADS)

    Davis, N. M.; Hodgkinson, J.; Francis, D.; Tatam, R. P.

    2016-04-01

    Detection of methane at 3.3μm using a DFB Interband Cascade Laser and gold coated integrating sphere is performed. A 10cm diameter sphere with effective path length of 54.5cm was adapted for use as a gas cell. A comparison between this system and one using a 25cm path length single-pass gas cell is made using direct TDLS and methane concentrations between 0 and 1000 ppm. Initial investigations suggest a limit of detection of 1.0ppm for the integrating sphere and 2.2ppm for the single pass gas cell. The system has potential applications in challenging or industrial environments subject to high levels of vibration.

  14. Palm top plasma focus device as a portable pulsed neutron source.

    PubMed

    Rout, R K; Niranjan, Ram; Mishra, P; Srivastava, R; Rawool, A M; Kaushik, T C; Gupta, Satish C

    2013-06-01

    Development of a palm top plasma focus device generating (5.2 ± 0.8) × 10(4) neutrons∕pulse into 4π steradians with a pulse width of 15 ± 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 μF capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 μF, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of (3)He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

  15. Palm top plasma focus device as a portable pulsed neutron source

    NASA Astrophysics Data System (ADS)

    Rout, R. K.; Niranjan, Ram; Mishra, P.; Srivastava, R.; Rawool, A. M.; Kaushik, T. C.; Gupta, Satish C.

    2013-06-01

    Development of a palm top plasma focus device generating (5.2 ± 0.8) × 104 neutrons/pulse into 4π steradians with a pulse width of 15 ± 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 μF capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 μF, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of 3He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

  16. Coordinated Body Bending Improves Performance of a Salamander-like Robot

    NASA Astrophysics Data System (ADS)

    Ozkan Aydin, Yasemin; Chong, Baxi; Gong, Chaohui; Rieser, Jennifer M.; Choset, Howie; Goldman, Daniel I.

    Analyzing body morphology and limb-body coordination in animals that can both swim and walk is important to understand the evolutionary transition from an aquatic to a terrestrial environment. Based on previous salamander experiments (a modern analog to early tetrapods and performed by Hutchinson's group at RVC in the UK) we built a robophysical model of a salamander and tested its performance on yielding granular media (GM) of poppy seeds. Our servo-driven robot (405 g, 38 cm long) has four limbs, a flexible body, and an active tail. Each limb has two servo motors to control up/down and fore/aft positions of limb. A joint in the middle of the body controls horizontal bending. We assessed performance of the robot by changing the body bending limit from 0°to 90°and measured body displacement and power consumption over a few limb cycles at 0°and 10°sandy slope. We fixed the angle of the legs according to body to test the effect of body bending directly. On GM, step length increased from 0 to 9.5 cm at 0° and 0 to 7 cm at 10°slope while the average power consumption increased 50 % . A geometric mechanics model revealed that on level GM body bending was most beneficial when phase offset 180°from leg movements; increasing the maximum body angular bend from 45°to 90° led to step length increases of up to 90 % .

  17. Efficiency enhancement of solution-processed inverted organic solar cells with a carbon-nanotube-doped active layer

    NASA Astrophysics Data System (ADS)

    Lin, Wen-Kai; Su, Shui-Hsiang; Yeh, Meng-Cheng; Huang, Yang-Chan; Yokoyama, Meiso

    2016-01-01

    Solution-processed titanium-doped ZnO (TZO) is synthesized by the sol-gel method to be the electron-transporting layer (ETL) in an inverted organic solar cell (IOSC). Carbon nanotubes (CNTs) are doped into an active layer of poly(3-hexylthiophene):[6,6]-phenyl C 61 butyric acid methyl ester (P3HT:PCBM). The addition of CNTs in the P3HT:PCBM composite increases the conjugation length of P3HT:PCBM:CNTs, which simultaneously enhances the capacity of the composite to absorb solar energy radiation. Vanadium oxide (V2O5) was spin-coated onto the active layer to be a hole-transporting layer (HTL). The power conversion efficiency (PCE) results indicate that the V2O5 nanobelt structure possesses better phase separation and provides a more efficient surface area for the P3HT:PCBM:CNT active layer to increase photocurrent. The optimized IOSCs exhibited an open circuit voltage (Voc), a short-circuit current density (Jsc), a fill factor (FF), and a PCE of 0.55 V, 6.50 mA/cm2, 58.34%, and 2.20%, respectively, under simulated AM1.5G illumination of 100 mW/cm2.

  18. Acute toxicity of organochlorine insecticide endosulfan to the giant freshwater prawn Macrobrochium rosenbergii

    NASA Astrophysics Data System (ADS)

    Dai, Xilin; Xiong, Zhaodi; Xie, Jian; Ding, Fujiang

    2014-01-01

    Endosulfan, an organochlorine pesticide, is highly toxic and effective at controlling pests in agriculture, horticulture, and public health programs. In this study, static bioassays were used to evaluate the toxicity of endosulfan to freshwater prawns ( Macrobrachium rosenbergii) of various lengths (1.5±0.03, 4±0.08, and 7±0.06 cm). Additionally, the activities of peroxidase (POD), acid phosphatase (ACP), alkaline phosphatase, acetylcholinesterase (AChE), and Na+/K+-ATPase were analyzed to reflect the effects of endosulfan exposure. The 96 h LC50 of endosulfan for prawns 1.5, 4, and 7 cm long were 1.86, 4.53, and 6.09 μg/L, respectively, improved tolerance to endosulfan with growth. The POD activities of test organisms exposed to low concentrations of endosulfan were inhibited, indicating the presence of oxygen damaged tissue. Moreover, a notable decrease in AChE activity was observed due to overstimulation of neurotransmission, which might result in abnormal behavior. The effect caused by endosulfan on phosphatase production in the hepatopancreas of prawns 1.5, 4, and 7 cm long was different because the ability of nonspecific immune regulation increased with growth. The 96 h LC50 values obtained in this study could be used in the formulation of water-quality criteria in China. Moreover, the changes in enzymes activities of M. rosenbergii under stress of endosulfan could be applied in the establishment of early warning indicators for bio-safety.

  19. A clinical correlation between stature and posterior tooth length.

    PubMed

    Reddy, Smitha; Shome, Bhuvan; Patil, Jayaprakash; Koppolu, Pradeep

    2017-01-01

    Exploration and determination of the relationship between stature and length of tooth is essential in Paleontology, Forensic Odontology and Endodontology. This study aimed to determine any association between stature and posterior tooth length in a group of patients who required root canal treatment. Age, sex and standing height of adults were considered for posterior tooth length measurement. Molars and Premolars of apparently normal males (n=115 for molars, n= 75 for premolars) and females (n=124 for molars, n=80 for premolars), aged 20-50 years with intact cuspal morphology, which required RCT were selected for this study. Females and males were divided into 2 groups each based on their heights females > 155 cm and ≤ 155 cm, males > 165.10 and ≤ 165.10cm. The tooth length of permanent molars and premolars in both groups were measured using RVG and Electronic apex locator. Measurements obtained were compared separately for males and females using descriptive statistics and Pearson correlation coefficient. In females MB, ML, D roots of molar showed significant association (P=0.021), (P=0.027), (P=0.010) and roots of premolars showed significant association (P=0.002), (P=0.006) between both the groups respectively In males MB, ML, D roots of molar showed significant association (P=0.009), (P=0.004), (P=0.015) and roots of premolars showed significant association (P=0.006), (P=0.020) between both the groups respectively. The present clinical study reveals that there is a positive association between stature and posterior tooth length in both males and females.

  20. Magnetic Design Guidelines for Electronic Power Supplies.

    DTIC Science & Technology

    1986-09-30

    henries ",= peak flux density in gauss d = wire (conductor) dia in mils CM = d2 = circular mi’s Irms = RMS current in amperes Idc = DC current in...component lac = RMS ac current in the inductor f = minimum frequency in hertz L = inductance in henries Then Eac 2 16.83 x 2, x 760 x .05 10 Eac 1 168.3 x 2...duty cycle x 1/f L inductance in henries *permeability in gauss/oersted H magnetizing force in oersteds ’. i g length of air gap in cm ic length of

  1. Mechanism of Action of the Transobturator Sling for Post-Radical Prostatectomy Incontinence: A Multi-institutional Prospective Study Using Dynamic Magnetic Resonance Imaging.

    PubMed

    Kahokehr, Arman A; Selph, John P; Belsante, Michael J; Bashir, Mustafa; Sofue, Keitaro; Tausch, Timothy J; Brand, Timothy C; Lloyd, Jessica C; Goldsmith, Zachariah G; Walter, Jack R; Peterson, Andrew C

    2018-06-01

    To compare the length of the membranous (functional) urethra in male patients who underwent the male transobturator sling (TOS) for postradical prostatectomy urinary incontinence (PPI). The TOS is in established use for treatment of PPI; however, the precise mechanism of action is unknown. This is a prospective case-controlled study on men undergoing male TOS surgery from 2008 to 2014. The comparison arm included patients without incontinence after radical prostatectomy. All participants underwent dynamic magnetic resonance imaging (MRI) at baseline and this was repeated after TOS placement for those who underwent the procedure. Three standardized points were measured using MRI and compared in both groups in addition to clinical measures. Thirty-nine patients were enrolled and 31 patients completed the protocols. The controls (N = 14) had a longer vesicourethral anastomosis to urethra measured at the penile bulb (functional urethral length) distance compared to the pre-TOS group at rest (1.92 cm controls vs 1.27 cm pre-TOS, P = .0018) and at Valsalva (2.13 cm controls vs 1.72 cm pre-TOS, P = .0371). Placement of the sling (N = 17) increased the functional urethral length distance at rest (1.92 cm control vs 1.53 cm post-TOS, P = .09) and at Valsalva (1.94 cm post-TOS vs 2.13 cm control, P = .61), so that the difference was no longer statistically significant. We identified that one possible mechanism in improvement in stress urinary incontinence post-TOS placement is the lengthening of the vesicourethral anastomosis to bulbar-urethra distance. This is the first such study utilizing dynamics MRI in post prostatectomy controls, incontinent pre-TOS, and post-TOS to assess and show these findings. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Crustal deformation associated with east Mediterranean strike-slip earthquakes: The 8 June 2008 Movri (NW Peloponnese), Greece, earthquake (M w6.4)

    NASA Astrophysics Data System (ADS)

    Papadopoulos, Gerassimos A.; Karastathis, Vassilis; Kontoes, Charalambos; Charalampakis, Marinos; Fokaefs, Anna; Papoutsis, Ioannis

    2010-09-01

    The 2008 mainshock ( Mw = 6.4) was the first modern, strong strike-slip earthquake in the Greek mainland. The fault strikes NE-SW, dips ˜ 85°NW while the motion was right-lateral with small reverse component. Historical seismicity showed no evidence that the fault ruptured in the last 300 years. For rectangular planar fault we estimated fault dimensions from aftershock locations. Dimensions are consistent with that a buried fault was activated, lateral expansion occurred only along length and the rupture stopped at depth ˜ 20 km implying that more rupture along length was favoured. We concluded that no major asperities remained unbroken and that the aftershock activity was dominated rather by creeping mechanism than by the presence of locked patches. For Mo = 4.56 × 10 25 dyn cm we calculated average slip of 76 cm and stress drop Δσ ˜ 13 bars. This Δσ is high for Greek strike-slip earthquakes, due rather to increased rigidity because of the relatively long recurrence ( Τ > 300 years) of strong earthquakes in the fault, than to high slip. Values of Δσ and Τ indicated that the fault is neither a typical strong nor a typical weak fault. Dislocation modeling of a buried fault showed uplift of ˜ 8.0 cm in Kato Achaia ( Δ ˜ 20 km) at the hanging wall of the reverse fault component. DInSAR analysis detected co-seismic motion only in Kato Achaia where interferogram fringes pattern showed vertical displacement from 3.0 to 6.0 cm. From field-surveys we estimated maximum intensity of VIII in Kato Achaia. The most important liquefaction spots were also observed there. These observations are attributable neither to surface fault-breaks nor to site effects but possibly to high ground acceleration due to the co-seismic uplift. The causal association between displacement and earthquake damage in the hanging wall described for dip-slip faults in Taiwan, Greece and elsewhere, becomes possible also for strike-slip faults with dip-slip component, as the 2008 earthquake.

  3. Effect of ultrasonic stimulation on particle transport and fate over different lengths of porous media

    NASA Astrophysics Data System (ADS)

    Chen, Xingxin; Wu, Zhonghan; Cai, Qipeng; Cao, Wei

    2018-04-01

    It is well established that seismic waves traveling through porous media stimulate fluid flow and accelerate particle transport. However, the mechanism remains poorly understood. To quantify the coupling effect of hydrodynamic force, transportation distance, and ultrasonic stimulation on particle transport and fate in porous media, laboratory experiments were conducted using custom-built ultrasonic-controlled soil column equipment. Three column lengths (23 cm, 33 cm, and 43 cm) were selected to examine the influence of transportation distance. Transport experiments were performed with 0 W, 600 W, 1000 W, 1400 W, and 1800 W of applied ultrasound, and flow rates of 0.065 cm/s, 0.130 cm/s, and 0.195 cm/s, to establish the roles of ultrasonic stimulation and hydrodynamic force. The laboratory results suggest that whilst ultrasonic stimulation does inhibit suspended-particle deposition and accelerate deposited-particle release, both hydrodynamic force and transportation distance are the principal controlling factors. The median particle diameter for the peak concentration was approximately 50% of that retained in the soil column. Simulated particle-breakthrough curves using extended traditional filtration theory effectively described the experimental curves, particularly the curves that exhibited a higher tailing concentration.

  4. An AFLP genetic linkage map of pacific abalone ( Haliotis discus hannai)

    NASA Astrophysics Data System (ADS)

    Qi, Li; Yanhong, Xu; Ruihai, Yu; Akihiro, Kijima

    2007-07-01

    A genetic linkage map of Pacific abalone ( Haliotis discus hannai) was constructed using AFLP markers based on a two-way pseudo-testeross strategy in a full-sib family. With 33 primer combinations, a total of 455 markers (225 from the female parent and 230 from the male parent) segregated in a 1:1 ratio, corresponding to DNA polymorphism: heterozygous in one parent and null in the other. The female framework map consisted of 174 markers distributed in 18 linkage groups, equivalent to the H. discus hannai haploid chromosome number, and spanning a total length of 2031.4 cM, with an average interval of 13.0 cM between adjacent markers. The male framework map consisted of 195 markers mapped on 19 linkage groups, spanning a total length of 2273.4 cM, with an average spacing of 12.9 cM between adjacent markers. The estimated coverage for the framework linkage maps was 81.2% for the female and 82.1% for the male, on the basis of two estimates of genome length. Fifty-two markers (11.4%) remained unlinked. The level of segregation distortion observed in this cross was 20.4%. These linkage maps will serve as a starting point for linkage studies in the Pacific abalone with potential application for marker-assisted selection in breeding programs.

  5. Multidetector row computed tomography evaluation of the micropig kidney as a potential renal donor.

    PubMed

    Yoon, Woong; Lee, Min Young; Ryu, Jung Min; Moon, Yong Ju; Lee, Sang Hun; Park, Jae Hong; Yun, Seung Pil; Jang, Min Woo; Park, Sung Su; Han, Ho Jae

    2010-03-01

    Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 +/- 0.05 and 4.51 +/- 0.55 cm on the right side and 0.46 +/- 0.06 and 3.36 +/- 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 +/- 0.52 and 4.22 +/- 1.29 cm on the right side and 1.38 +/- 0.17 and 5.15 +/- 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 +/- 14.5 mL and of the left kidney was 78.0 +/- 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.

  6. Application of Atmospheric-Pressure Microwave Line Plasma for Low Temperature Process

    NASA Astrophysics Data System (ADS)

    Suzuki, Haruka; Nakano, Suguru; Itoh, Hitoshi; Sekine, Makoto; Hori, Masaru; Toyoda, Hirotaka

    2015-09-01

    Atmospheric pressure (AP) plasmas have been given much attention because of its high cost benefit and a variety of possibilities for industrial applications. In various kinds of plasma production technique, pulsed-microwave discharge plasma using slot antenna is attractive due to its ability of high-density and stable plasma production. In this plasma source, however, size of the plasma has been limited up to a few cm in length due to standing wave inside a waveguide. To solve this, we have proposed a newly-developed AP microwave plasma source that utilizes not standing wave but travelling wave. By using this plasma source, spatially-uniform AP line plasma with 40 cm in length was realized by pure helium discharge in 60 cm slot and with nitrogen gas additive of 1%. Furthermore, gas temperature as low as 400 K was realized in this device. In this study, as an example of low temperature processes, hydrophilic treatment of PET films was performed. Processing speed increased with pulse frequency and a water contact angle of ~20° was easily obtained within 5 s with no thermal damage to the substrate. To evaluate treatment-uniformity of long line length, PET films were treated by 90 cm slot-antenna plasma and uniform treatment performance was confirmed.

  7. [The importance of handprint morphometry for determining the human body length].

    PubMed

    Grigor'eva, M A

    2018-01-01

    Handprint morphometry for the purpose of personality identification still remains a relatively novel approach. The methods employed for the measurements are not infrequently difficult to reproduce and therefore cause controversy. The objective of the present study was to introduce the system of methods for the measurement of handprints suitable for the reliable determination of the human body length. The study included the measurement of the size of 40 handprints left by124 adult subjects (52 men and 72 women). Two methods of the regression analysis, stepwise and forced inclusion, were applied to the combined group of handprints to select the equations with the high (R>0.800) coefficients of multiple correlation with the body length. 13 equations of multiple regression were obtained and analyzed. The standard error of estimating (SEE) varied from 4.30 to 5.19 cm. The best results were obtained with the equations constructed from the sizes I, II, and III of the rays without their distal phalanges. It was shown that the body length can be successfully reconstructed within the height range from 168 to 183 cm for men and from 157 to 176 cm for women. The examples of the use of the equations for the purpose of expertise of illegible and incomplete handprints are presented.

  8. A Novel Concept of Amino Acid Supplementation to Improve the Growth of Young Malnourished Male Rats.

    PubMed

    Furuta, Chie; Murakami, Hitoshi

    2018-01-01

    This study was aimed at understanding the relationship between plasma amino acids and protein malnutrition and at determining whether amino acid supplementation associated with malnutrition and growth improves linear growth in growing rats. Body length and plasma amino acids were measured in young male rats that were fed the following diet for 3 weeks, mimicking a low and imbalanced protein diets based on maize, a major staple consumed in developing countries: a 70% calorically restricted cornmeal-based diet (C), C + micronutrients (CM), CM + casein (CMC), CM + soy protein (CMS) or CMS + 0.3% lysine. A correlation analysis of linear growth and plasma amino acids indicated that lysine, tryptophan, branched-chain amino acids, methionine, and phenylalanine significantly correlated with body length. Supplementation with these 5 amino acids (AA1) significantly improved the body length in rats compared to CMC treatment whereas, nitrogen-balanced amino acid supplemented controls (AA2) did not (CM +1.2 ± 0.2, CMC +2.7 ± 0.3, CMS +2.1 ± 0.3, AA1 +2.8 ± 0.2, and AA2 +2.5 ± 0.3 cm). With securing proper amino acid balance, supplementing growth-related amino acids is more effective in improving linear growth in malnourished growing male rats. Analysis of the correlation between plasma amino acids and growth represents a powerful tool to determine candidate amino acids for supplementation to prevent malnutrition. This technology is adaptable to children in developing countries. © 2018 S. Karger AG, Basel.

  9. Life history of the silvertip shark Carcharhinus albimarginatus from Papua New Guinea

    NASA Astrophysics Data System (ADS)

    Smart, Jonathan J.; Chin, Andrew; Baje, Leontine; Tobin, Andrew J.; Simpfendorfer, Colin A.; White, William T.

    2017-06-01

    Growth and maturity of the silvertip shark Carcharhinus albimarginatus from Papua New Guinea were estimated to form the basis of future population assessments. Samples were collected from commercial longline vessels targeting sharks in the Bismarck and Solomon Seas. A total of 48 C. albimarginatus—28 males (95-219 cm total length, TL) and 20 females (116-250 cm TL)—provided data for the analyses. Employing back-calculation techniques accounted for missing juvenile length classes and supplemented the sample size. A multi-model framework incorporating the Akaike information criterion was used to estimate growth parameters. The von Bertalanffy growth function (VBGF) provided the best-fit growth estimates. Parameter estimates were L 0 = 72.1 cm TL, k = 0.04 yr-1 and L ∞ = 311.3 cm TL for males; and L 0 = 70.8 cm TL, k = 0.02 yr-1 and L ∞ = 497.9 cm TL for females. The biologically implausible L ∞ occurred for females as their growth did not asymptote; a typical trait of large shark species. The maximum age estimated from vertebral analysis was 18 yr for both sexes, while the calculated longevity from the VBGF parameters was 27.4 yr for males and 32.2 yr for females. Males matured at 174.7 cm TL and 10.5 yr old, while females matured at 208.9 cm TL and 14.8 yr old.

  10. Natural Fiber Cut Machine Semi-Automatic Linear Motion System for Empty Fiber Bunches: Re-designing for Local Use

    NASA Astrophysics Data System (ADS)

    Asfarizal; Kasim, Anwar; Gunawarman; Santosa

    2017-12-01

    Empty Palm bunches of fiber is local ingredient in Indonesia that easy to obtain. Empty Palm bunches of fiber can be obtained from the palm oil industry such as in West Pasaman. The character of the empty Palm bunches of fiber that is strong and pliable has high-potential for particle board. To transform the large quantities of fiber become particles in size 0-10 mm requires a specially designed cut machine. Therefore, the machine is designed in two-stage system that is mechanical system, structure and cutting knife. Components that have been made, assembled and then tested to reveal the ability of the machine to cut. The results showed that the straight back and forth motion cut machine is able to cut out the empty oil palm bunches of fiber with a length 0-1 cm, 2 cm, 8 cm and the surface of the cut is not stringy. The cutting capacity is at a length of 2 cm in the result 24.4 (kg/h) and 8 cm obtained results of up to 84 (kg/h)

  11. Genetic Mutations, Birth Lengths, Weights and Head Circumferences of Children with IGF-I Receptor Defects. Comparison with other Congenital Defects in the GH/IGF-I axis.

    PubMed

    Essakow, Jenna Lee; Lauterpacht, Aharon; Lilos, Pearl; Kauli, Rivka; Laron, Zvi

    2016-09-01

    In recent years more and more genetic defects along the GHRH-GH-IGF-I axis have been reported. Mutations of the IGF-I receptor (R) are a rare abnormality of whom only the heterozygote progenies survive. To summarize, from the literature, data on birth length, weight and head circumference of neonates with IGF-I-R mutations, and to correlate the data with that of other types of mutations in the GH/IGF-I axis. Sixty seven neonates from 24 published articles were included and forty seven different mutations of the IGF-I (R) located on chromosome 15 have been identified. Mean (±SD) birth length (BL), available for 26, (10 M, 16F) neonates with a gestational age of 34-41weeks, was 44.2±4cm; one was premature (30cm at 31 weeks). There was a significant correlation between birth length and gestational age (GA) r=0.71 (p>.001). Mean birth weight (BW) of 41 neonates (18M, 23F) was 2388±743gr. Two premature neonates weighed 650gr and 950gr respectively. The BW correlated significantly with gestational age, (males: r=0.68; p=0.007, females: r=0.49; p=0.024). The BMI of 25 neonates ranged from 6 to 13. In 22 records marked microcephaly was ascertained or stated. Nine of 16 mothers were short (133 -148cm), m±SD = 150.5±7.3cm. Copyright© of YS Medical Media ltd.

  12. Tolerability and efficacy of newly developed penile injection of cross-linked dextran and polymethylmethacrylate mixture on penile enhancement: 6 months follow-up.

    PubMed

    Yang, D Y; Lee, W K; Kim, S C

    2013-05-01

    Cross-linked dextran and polymethylmethacrylate mixture (Lipen-10) is newly developed tissue filler. The purpose of this study was to evaluate tolerability and efficacy of Lipen-10 on penile enhancement. Twenty adult males were included in this study. Lipen-10 was injected into the subcutaneous tissue of the penile shaft. The penile girth and length were measured in the flaccid state, before and 1, 3 and 6 months after the injection. The circumference increased by 3.7±1.2 cm (50.8%, P<0.0001) at penile base, 4.2±0.9 cm (59.0%, P<0.001) at mid-shaft, and 3.8±1.0 cm (53.2%, P<0.0001) at distal shaft and the length increased by 2.3±1.4 cm (63.2%, P<0.001). There was, however, no significant difference between 3 and 6 months post-treatment in girth and length (P-values: 0.796, 0.498, 0.600 and 0.084 for penile base, mid- and distal-shaft and length, respectively). The complications were only one mild asymmetry of penile shape and one 5-mm-sized nodule in the injected site. There were no clinically significant adverse events in all subjects. Penile injection of Lipen-10 led to a significant increase in penile size, showed a good durability and was well-tolerated, without serious adverse events. These results suggest that penile injection of Lipen-10 may be a new effective method for penile enhancement.

  13. Testing a model of componential processing of multi-symbol numbers-evidence from measurement units.

    PubMed

    Huber, Stefan; Bahnmueller, Julia; Klein, Elise; Moeller, Korbinian

    2015-10-01

    Research on numerical cognition has addressed the processing of nonsymbolic quantities and symbolic digits extensively. However, magnitude processing of measurement units is still a neglected topic in numerical cognition research. Hence, we investigated the processing of measurement units to evaluate whether typical effects of multi-digit number processing such as the compatibility effect, the string length congruity effect, and the distance effect are also present for measurement units. In three experiments, participants had to single out the larger one of two physical quantities (e.g., lengths). In Experiment 1, the compatibility of number and measurement unit (compatible: 3 mm_6 cm with 3 < 6 and mm < cm; incompatible: 3 cm_6 mm with 3 < 6 but cm > mm) as well as string length congruity (congruent: 1 m_2 km with m < km and 2 < 3 characters; incongruent: 2 mm_1 m with mm < m, but 3 > 2 characters) were manipulated. We observed reliable compatibility effects with prolonged reaction times (RT) for incompatible trials. Moreover, a string length congruity effect was present in RT with longer RT for incongruent trials. Experiments 2 and 3 served as control experiments showing that compatibility effects persist when controlling for holistic distance and that a distance effect for measurement units exists. Our findings indicate that numbers and measurement units are processed in a componential manner and thus highlight that processing characteristics of multi-digit numbers generalize to measurement units. Thereby, our data lend further support to the recently proposed generalized model of componential multi-symbol number processing.

  14. Predicting paddlefish roe yields using an extension of the Beverton–Holt equilibrium yield-per-recruit model

    USGS Publications Warehouse

    Colvin, M.E.; Bettoli, Phillip William; Scholten, G.D.

    2013-01-01

    Equilibrium yield models predict the total biomass removed from an exploited stock; however, traditional yield models must be modified to simulate roe yields because a linear relationship between age (or length) and mature ovary weight does not typically exist. We extended the traditional Beverton-Holt equilibrium yield model to predict roe yields of Paddlefish Polyodon spathula in Kentucky Lake, Tennessee-Kentucky, as a function of varying conditional fishing mortality rates (10-70%), conditional natural mortality rates (cm; 9% and 18%), and four minimum size limits ranging from 864 to 1,016mm eye-to-fork length. These results were then compared to a biomass-based yield assessment. Analysis of roe yields indicated the potential for growth overfishing at lower exploitation rates and smaller minimum length limits than were suggested by the biomass-based assessment. Patterns of biomass and roe yields in relation to exploitation rates were similar regardless of the simulated value of cm, thus indicating that the results were insensitive to changes in cm. Our results also suggested that higher minimum length limits would increase roe yield and reduce the potential for growth overfishing and recruitment overfishing at the simulated cm values. Biomass-based equilibrium yield assessments are commonly used to assess the effects of harvest on other caviar-based fisheries; however, our analysis demonstrates that such assessments likely underestimate the probability and severity of growth overfishing when roe is targeted. Therefore, equilibrium roe yield-per-recruit models should also be considered to guide the management process for caviar-producing fish species.

  15. Musculoaponeurotic Area of the Hip and Clinicophotographic Scaling System

    PubMed Central

    Mena-Chávez, J. Alejandro

    2015-01-01

    Background: With the evolution of body contouring, few innovative alternatives have been developed for cosmetic treatment in the hip area. Methods: A multicenter controlled study was conducted, including a prior review of the literature regarding the hip area. Dissections were performed on 4 male cadavers, outlining the “musculoaponeurotic area of the hip.” The area was subdivided into anterior and posterior surfaces. A clinical study was conducted in 79 patients, obtaining a scale by using the most prominent points on the sides of both thighs as the main reference. With the lines marked on photographs and the measurements, a “clinicophotographic scaling system” was designed. Results: The anterior surface corresponds to the tensor fasciae latae and its tendon as well as to the aponeurosis of the gluteus medius. The posterior surface corresponds with the iliotibial tract and the tendon insertions of the gluteus maximus. The average dimensions of the cadaver “musculoaponeurotic area of the hip” are as follows: length, 17.5 cm, and width, 11.5 cm. Using the “clinicophotographic scaling system,” the dimensions are as follows: length, 14.9 cm, and width, 10.3 cm. Conclusions: The “musculoaponeurotic area of the hip” was defined involving muscles, tendons, aponeurosis, fascia, subcutaneous cellular tissue, and skin. The borders were established using important anatomical points that determine the length and width of the area. The “clinicophotographic scaling system” was used to clinically calculate the length and width of the area. By examination and palpation, the borders and dimensions of this area could be determined. PMID:26180724

  16. Ecological-site based assessments of wind and water erosion: informing management of accelerated soil erosion in rangelands

    NASA Astrophysics Data System (ADS)

    Webb, N.; Herrick, J.; Duniway, M.

    2013-12-01

    This work explores how soil erosion assessments can be structured in the context of ecological sites and site dynamics to inform systems for managing accelerated soil erosion. We evaluated wind and water erosion rates for five ecological sites in southern New Mexico, USA, using monitoring data and rangeland-specific wind and water erosion models. Our results show that wind and water erosion can be highly variable within and among ecological sites. Plots in shrub-encroached and shrub-dominated states were consistently susceptible to both wind and water erosion. However, grassland plots and plots with a grass-succulent mix had a high indicated susceptibility to wind and water erosion respectively. Vegetation thresholds for controlling erosion are identified that transcend the ecological sites and their respective states. The thresholds define vegetation cover levels at which rapid (exponential) increases in erosion rates begin to occur, suggesting that erosion in the study ecosystem can be effectively controlled when bare ground cover is <20% of a site or total ground cover is >50%. Similarly, our results show that erosion can be controlled when the cover of canopy interspaces >50 cm in length reaches ~50%, the cover of canopy interspaces >100 cm in length reaches ~35% or the cover of canopy interspaces >150 cm in length reaches ~20%. This process-based understanding can be applied, along with knowledge of the differential sensitivity of vegetation states, to improve erosion management systems. Land use and management activities that alter cover levels such that they cross thresholds, and/or drive vegetation state changes, may increase the susceptibility of sites to erosion. Land use impacts that are constrained within the natural variability of sites should not result in accelerated soil erosion. Evaluating land condition against the erosion thresholds and natural variability of ecological sites will enable improved identification of where and when accelerated soil erosion occurs and the development of practical management solutions.

  17. Electropolymerized polyazulene as active material in flexible supercapacitors

    NASA Astrophysics Data System (ADS)

    Suominen, Milla; Lehtimäki, Suvi; Yewale, Rahul; Damlin, Pia; Tuukkanen, Sampo; Kvarnström, Carita

    2017-07-01

    We report the capacitive behavior of electrochemically polymerized polyazulene films in different ionic liquids. The ionic liquids in this study represent conventional imidazolium based ionic liquids with tetrafluoroborate and bis(trifluoromethylsulfonyl)imide anions as well as an unconventional choline based ionic liquid. The effect of different ionic liquids on the polymerization and capacitive performance of polyazulene films is demonstrated by cyclic voltammetry and electrochemical impedance spectroscopy in a 3-electrode cell configuration. The films exhibit the highest capacitances in the lowest viscosity ionic liquid (92 mF cm-2), while synthesis in high viscosity ionic liquid shortens the conjugation length and results in lower electroactivity (25 mF cm-2). The obtained films also show good cycling stabilities retaining over 90% of their initial capacitance over 1200 p-doping cycles. We also demonstrate, for the first time, flexible polyazulene supercapacitors of symmetric and asymmetric configurations using the choline based ionic liquid as electrolyte. In asymmetric configuration, capacitance of 55 mF (27 mF cm-2) with an equivalent series resistance of 19 Ω is obtained at operating voltage of 1.5 V. Upon increasing the operating voltage up to 2.4 V, the capacitance increases to 72 mF (36 mF cm-2).

  18. Silicon enhances suberization and lignification in roots of rice (Oryza sativa).

    PubMed

    Fleck, Alexander T; Nye, Thandar; Repenning, Cornelia; Stahl, Frank; Zahn, Marc; Schenk, Manfred K

    2011-03-01

    The beneficial element silicon (Si) may affect radial oxygen loss (ROL) of rice roots depending on suberization of the exodermis and lignification of sclerenchyma. Thus, the effect of Si nutrition on the oxidation power of rice roots, suberization and lignification was examined. In addition, Si-induced alterations of the transcript levels of 265 genes related to suberin and lignin synthesis were studied by custom-made microarray and quantitative Real Time-PCR. Without Si supply, the oxidation zone of 12 cm long adventitious roots extended along the entire root length but with Si supply the oxidation zone was restricted to 5 cm behind the root tip. This pattern coincided with enhanced suberization of the exodermis and lignification of sclerenchyma by Si supply. Suberization of the exodermis started, with and without Si supply, at 4-5 cm and 8-9 cm distance from the root tip (drt), respectively. Si significantly increased transcript abundance of 12 genes, while two genes had a reduced transcript level. A gene coding for a leucine-rich repeat protein exhibited a 25-fold higher transcript level with Si nutrition. Physiological, histochemical, and molecular-biological data showing that Si has an active impact on rice root anatomy and gene transcription is presented here.

  19. Extracellular enzyme activity in a willow sewage treatment system.

    PubMed

    Brzezinska, Maria Swiontek; Lalke-Porczyk, Elżbieta; Kalwasińska, Agnieszka

    2012-12-01

    This paper presents the results of studies on the activity of extra-cellular enzymes in soil-willow vegetation filter soil which is used in the post-treatment of household sewage in an onsite wastewater treatment system located in central Poland. Wastewater is discharged from the detached house by gravity into the onsite wastewater treatment system. It flows through a connecting pipe into a single-chamber septic tank and is directed by the connecting pipe to a control well to be further channelled in the soil-willow filter by means of a subsurface leaching system. Soil samples for the studies were collected from two depths of 5 cm and 1 m from three plots: close to the wastewater inflow, at mid-length of the plot and close to its terminal part. Soil samples were collected from May to October 2009. The activity of the extra-cellular enzymes was assayed by the fluorometric method using 4-methylumbelliferyl and 7-amido-4-methylcoumarin substrate. The ranking of potential activity of the assayed enzymes was the same at 5 cm and 1 m soil depths, i.e. esterase > phosphmomoesterase > leucine-aminopeptidase > β-glucosidase > α-glucosidase. The highest values of enzymatic activity were recorded in the surface layer of the soil at the wastewater inflow and decreased with increasing distance from that point.

  20. Historical trend in heavy metal pollution in core sediments from the Masan Bay, Korea.

    PubMed

    Cho, Jinhyung; Hyun, Sangmin; Han, J-H; Kim, Suhyun; Shin, Dong-Hyeok

    2015-06-15

    The spatiotemporal distribution and their mass accumulation rate (MAR) of heavy metals were investigated to evaluate the time-dependent historical trends of heavy metal concentration. The three short cores used for this study were collected from the catchment area (MS-PC5, 60cm length), the central part (MS-PC4, 40cm length) and the offshore (MS-PC2, 60cm length) of the Masan Bay, Korea. The concentration of heavy metals (Co, Ni, Cu, Zn, Cr and Pb) in catchment area is as much as 1.5-2 times higher than central part of the Bay, and about 2 times higher than offshore area approximately. In particular, MAR of metals (Cu, Zn and Pb) show clear spatiotemporal variation, so that MAR's of heavy metal may provide more accurate information in evaluating the degree of pollution. Temporally, the heavy metal concentration had been increased since the late 1970s, but it seems to decrease again since the 2004yr in catchment area. This may came from concentrated efforts for the government to reduce industrial waste release. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. A high-sensitivity temperature sensor based on Sagnac interferometer employing photonic crystal fiber fully filled with ethanol

    NASA Astrophysics Data System (ADS)

    Shi, Min; Li, Shuguang; Chen, Hailiang

    2018-06-01

    A high-sensitivity temperature sensor based on photonic crystal fiber Sagnac interferometer is proposed and studied. All holes of the PCF are filled with ethanol with capillarity. The cladding air holes are uniform arrangements. The two air holes around the core are removed to form new core modes with high birefringence. The sensitivities of the temperature can be up to -8.7657 and 16.8142 nm/°C when temperature rises from 45 to 75 °C and the fiber length is 5.05 cm. And when temperature rises from 10 to 45 °C, the sensitivity can reach -7.848 and 16.655 nm/°C with fiber length 2.11 cm. The performance of the selective-filled and the fully-filled PCF with temperature from 45 to 75 °C and fiber length 5.05 cm are analyzed and compared. The fully filling can better achieve PCF's sensing performance. The simple structure and high sensitivities make the temperature sensor easy to achieve. The temperature sensor with high sensitivities and good linearity has great application value for environmental temperature detecting.

  2. A 10-cm Discharge-Length He-ZnII White Light Laser

    NASA Astrophysics Data System (ADS)

    Sasaki, Wakao; Itani, Kimihiko; Ohta, Tatehisa

    1989-06-01

    We demonstrate a unique, efficient white light laser source realized by the He-Zn mixture with substantially short discharge length of 10 cm. The white laser light can be made up of only two wavelengths at simultaneous oscillation --- 492.4 nm (4f2Fo712_4d2D5/2) and 610.2 nm (5d 2D 512 -5 2p03/2 The ideal white color region for human eyes lies just between these two wavelengths in the chromaticity diagram. Therefore, such a compact white light laser will be useful for some specific purposes such as a white color standard. Moreover, we have analyzed the proper relation between the electron energy and the discharge sustaining voltage which appears as a function of the Zn vapor pressure measured at the terminal of the tube, considering the Druyvesteyn distribution of electron energy. Then we succeeded to operate a He-Zn laser tube in white light with 10-cm discharge length. The derived output beam was estimated to be about 0.5 mW.

  3. End-compensated magnetostatic cavity for polarized 3He neutron spin filters.

    PubMed

    McIver, J W; Erwin, R; Chen, W C; Gentile, T R

    2009-06-01

    We have expanded upon the "Magic Box" concept, a coil driven magnetic parallel plate capacitor constructed out of mu-metal, by introducing compensation sections at the ends of the box that are tuned to limit end-effects similar to those of short solenoids. This ability has reduced the length of the magic box design without sacrificing any loss in field homogeneity, making the device far more applicable to the often space limited neutron beam line. The appeal of the design beyond affording longer polarized 3He lifetimes is that it provides a vertical guide field, which facilitates neutron spin transport for typical polarized beam experiments. We have constructed two end-compensated magic boxes of dimensions 28.4 x 40 x 15 cm3 (length x width x height) with measured, normalized volume-averaged transverse field gradients ranging from 3.3 x 10(-4) to 6.3 x 10(-4) cm(-1) for cell sizes ranging from 8.1 x 6.0 to 12.0 x 7.9 cm2 (diameter x length), respectively.

  4. Tricuspid Annular Plane Systolic Excursion and Its Association with Mortality in Critically Ill Patients.

    PubMed

    Gajanana, Deepakraj; Seetha Rammohan, Harish; Alli, Oluseun; Romero-Corral, Abel; Purushottam, Bhaskar; Ponamgi, Shiva; Figueredo, Vincent M; Pressman, Gregg S

    2015-08-01

    Transient left ventricular dysfunction can occur under conditions of extreme emotional or physiological stress. There is little data on right ventricular function in such situations. One hundred twenty patients admitted to an ICU with a noncardiac illness were studied. Those with documented coronary disease, ejection fraction <40%, sepsis, or intracranial hemorrhage were excluded. Echocardiograms were performed within 24 hours of admission. Tricuspid annular plane systolic excursion (TAPSE) was measured to assess right ventricular systolic function. Plasma catecholamines (norepinephrine, epinephrine, dopamine) were measured on admission. Clinical and demographic data were collected, along with data on ICU length of stay (LOS), hospital LOS, and in-hospital and long-term mortality. TAPSE was tested for correlation with adverse outcomes and length of stay. Mean TAPSE for the group was 2.05 ± 0.66 cm. Based on area under the ROC curve analysis, TAPSE <2.4 cm was the best cutoff for predicting in-hospital and long-term mortality. There were 13 in-hospital deaths, 12 in the group with TAPSE <2.4 cm and one among those with TAPSE ≥2.4 cm. On multivariate analysis, TAPSE <2.4 cm was a significant predictor of in-hospital mortality (χ(2)  = 4.6, P = 0.03). When tested against hospital LOS, an inverse correlation was found (P = 0.04). No association was found between TAPSE and catecholamine levels. Right ventricular systolic function, as assessed by TAPSE, has important prognostic value in critically ill patients. Mean values were lower in patients who died in-hospital versus those who survived to discharge. In addition, patients with TAPSE <2.4 cm had a longer hospital length of stay. © 2015, Wiley Periodicals, Inc.

  5. Palm top plasma focus device as a portable pulsed neutron source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rout, R. K.; Niranjan, Ram; Srivastava, R.

    2013-06-15

    Development of a palm top plasma focus device generating (5.2 {+-} 0.8) Multiplication-Sign 10{sup 4} neutrons/pulse into 4{pi} steradians with a pulse width of 15 {+-} 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is ofmore » 2 {mu}F capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 {mu}F, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of {sup 3}He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.« less

  6. Heat dissipation sensors of variable length for the measurement of sap flow in trees with deep sapwood.

    PubMed

    James, Shelley A; Clearwater, Michael J; Meinzer, Frederick C; Goldstein, Guillermo

    2002-03-01

    Robust thermal dissipation sensors of variable length (3 to 30 cm) were developed to overcome limitations to the measurement of radial profiles of sap flow in large-diameter tropical trees with deep sapwood. The effective measuring length of the custom-made sensors was reduced to 1 cm at the tip of a thermally nonconducting shaft, thereby minimizing the influence of nonuniform sap flux density profiles across the sapwood. Sap flow was measured at different depths and circumferential positions in the trunks of four trees at the Parque Natural Metropolitano canopy crane site, Panama City, Republic of Panama. Sap flow was detected to a depth of 24 cm in the trunks of a 1-m-diameter Anacardium excelsum (Bertero & Balb. ex Kunth) Skeels tree and a 0.65-m-diameter Ficus insipida Willd. tree, and to depths of 7 cm in a 0.34-m-diameter Cordia alliodora (Ruiz & Pav.) Cham. trunk, and 17 cm in a 0.47-m-diameter Schefflera morototoni (Aubl.) Maguire, Steyerm. & Frodin trunk. Sap flux density was maximal in the outermost 4 cm of sapwood and declined with increasing sapwood depth. Considerable variation in sap flux density profiles was observed both within and among the trees. In S. morototoni, radial variation in sap flux density was associated with radial variation in wood properties, particularly vessel lumen area and distribution. High variability in radial and circumferential sap flux density resulted in large errors when measurements of sap flow at a single depth, or a single radial profile, were used to estimate whole-plant water use. Diurnal water use ranged from 750 kg H2O day-1 for A. excelsum to 37 kg H2O day-1 for C. alliodora.

  7. Endoscopic Skipping of the Terminal Ileum in Pediatric Crohn Disease.

    PubMed

    Mansuri, Ishrat; Fletcher, Joel G; Bruining, David H; Kolbe, Amy B; Fidler, Jeff L; Samuel, Sunil; Tung, Jeanne

    2017-06-01

    Pediatric small-bowel (SB) Crohn disease (CD) may be missed if the terminal ileum (TI) appears normal at endoscopy and SB imaging is not performed. We sought to estimate the prevalence and clinical characteristics of pediatric patients with CD and endoscopic skipping of the TI-that is, pediatric patients with active SB or upper gut inflammation and an endoscopically normal TI. This retrospective study included pediatric patients with CD who underwent both CT enterography (CTE) or MR enterography (MRE) and ileocolonoscopy within a 30-day period between July 2004 and April 2014. The physician global assessment was used as the reference standard for SB CD activity. Radiologists reviewed the CTE and MRE studies for inflammatory parameters; severity, length, and multifocality of SB inflammation; and the presence of penetrating complications. Of 170 patients who underwent ileal intubation, the TI was macroscopically normal or showed nonspecific inflammation in 73 patients (43%). Nearly half (36/73, 49%) of the patients with normal or nonspecific findings at ileocolonoscopy had radiologically active disease with a median length of SB involvement of 20 cm (range, 1 to > 100 cm). Seventeen (47%) of these patients had multifocal SB involvement and five (14%) had penetrating complications. Overall, endoscopic TI skipping was present in 43 (59%) patients with normal or nonspecific ileocolonoscopic findings: 20 with histologic inflammation (17 with positive imaging findings), 14 with inflammation at imaging only, and nine with proximal disease (upper gut, jejunum, or proximal ileum). There were no significant differences in the clinical parameters of the patients with and those without endoscopic TI skipping. Ileocolonoscopy may miss SB CD in pediatric patients that is due to isolated histologic, intramural, or proximal inflammation. Enterography is complementary to ileocolonoscopy in the evaluation of pediatric CD.

  8. Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos).

    PubMed

    Kim, Hee Man; Yang, Sungwook; Kim, Jinseok; Park, Semi; Cho, Jae Hee; Park, Jeong Youp; Kim, Tae Song; Yoon, Eui-Sung; Song, Si Young; Bang, Seungmin

    2010-08-01

    Capsule endoscopy that could actively move and approach a specific site might be more valuable for the diagnosis or treatment of GI diseases. We tested the performance of active locomotion of a novel wired capsule endoscope with a paddling-based locomotion mechanism, using 3 models: a silicone tube, an extracted porcine colon, and a living pig. In vitro, ex vivo, and in vivo experiments in a pig model. Study in an animal laboratory. For the in vitro test, the locomotive capsule was controlled to actively move from one side of a silicone tube to the other by a controller-operated automatic traveling program. The velocity was calculated by following a video recording. We performed ex vivo tests by using an extracted porcine colon in the same manner we performed the in vitro test. In in vivo experiments, the capsule was inserted into the rectum of a living pig under anesthesia, and was controlled to move automatically forward. After 8 consecutive trials, the velocity was calculated. Elapsed time, velocity, and mucosal damage. The locomotive capsule showed stable and active movement inside the lumen both in vitro and ex vivo. The velocity was 60 cm/min in the silicone tube, and 36.8 and 37.5 cm/min in the extracted porcine colon. In the in vivo experiments, the capsule stably moved forward inside the colon of a living pig without any serious complications. The mean velocity was 17 cm/min over 40 cm length. We noted pinpoint erythematous mucosal injuries in the colon. Porcine model experiments, wired capsule endoscope. The novel paddling-based locomotive capsule endoscope performed fast and stable movement in a living pig colon with consistent velocity. Further investigation is necessary for practical use in humans. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  9. Determination of the appropriate catheter length for needle thoracostomy by using computed tomography scans of trauma patients in Japan.

    PubMed

    Yamagiwa, Takeshi; Morita, Seiji; Yamamoto, Rie; Seki, Tomoko; Sugimoto, Katsuhiko; Inokuchi, Sadaki

    2012-01-01

    Previous studies reported a high failure rate in relieving tension pneumothorax by needle thoracostomy, because the catheter was not sufficiently long to access the pleural space. The Advanced Trauma Life Support guideline recommends needle thoracostomy at the second intercostal space in the middle clavicular line using a 5.0-cm catheter, whereas the corresponding guideline in Japan does not mention a catheter length. It is necessary to measure the chest wall thickness (CWT) and determine the appropriate catheter length taking the differences of habitus in race and region into consideration. This study was designed to analyse CWT in Japanese trauma patients by computed tomography and to determine the percentage of patients whose pleural space would be accessible using a 5.0-cm catheter. We performed a retrospective review of chest computed tomography of 256 adult Japanese trauma patients who were admitted to the level 1 trauma centre of Tokai University Hospital in Kanagawa, Japan between January and July 2008. In 256 patients, the CWT at 512 sites (left and right sides) was measured by chest computed tomography at the second intercostal space in the middle clavicular line. The frequency of measurement sites <5.0 cm was calculated simultaneously. The samples were divided according to gender, side (left and right), abbreviated injury scale (<3, ≧3), arm position during examination (up/down), and the existence or non-existence of associated injuries (pneumothorax, subcutaneous emphysema, and fracture of the sternum and ribs); the CWT of each group was compared. The mean CWT measured in 192 males and 64 females was 3.06±1.02 cm. The CWT values at 483 sites (94.3%) were less than 5.0 cm. The CWT of females was significantly greater than that of males (3.66 cm vs. 2.85 cm, p<0.0001), and patients with subcutaneous emphysema had greater CWTs than those without it (4.16 cm vs. 3.01 cm, p<0.0001). The mean CWT at the second intercostal space in the middle clavicular line was 3.06 cm. It is likely that over 94% of Japanese trauma patients could be treated with a 5.0-cm catheter. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. Perineal body length and perineal lacerations during delivery in primigravid patients

    PubMed Central

    Lane, T. Lance; Chung, Christopher P.; Yandell, Paul M.; Kuehl, Thomas J.

    2017-01-01

    This study assessed the relation between perineal body length and the risk of perineal laceration extending into the anal sphincter during vaginal delivery in primigravid patients at an institution with a low utilization of episiotomy. This was a prospective study of primigravid patients in active labor. Primigravid women with singleton pregnancies who were in the first stage of labor at 37 weeks gestation or greater were recruited, and the admitting physician measured the length of the perineal body. The degree of perineal laceration and other delivery characteristics were recorded. Data were analyzed using univariate analyses, receiver-operator curve analyses, and multiple logistic regression for factors associated with increased severity of vaginal lacerations. The perineal body length, duration of second stage of labor, type of delivery, and patient age were associated (P < 0.1) with third- and fourth-degree (severe) perineal lacerations in primigravid women using receiver-operator curve analysis. Using logistic regression, only the duration of second stage of labor and length of the perineal body were significant (P < 0.04) predictors of third- and fourth-degree lacerations, with odds ratios of 32 (1.3 to 807 as 95% CI) and 24 (1.3 to 456), respectively. Both a perineal body length of ≤3.5 cm and a duration of second stage of labor >99 minutes were associated with an increased risk of third- and fourth-degree lacerations in primigravid patients. PMID:28405063

  11. The Effects of Angular Orientation on Flame Spread over Thin Materials

    DTIC Science & Technology

    1999-12-01

    Notation 7 5 Upward Spread With Burnout 8 6a Observed Flame Lengths on Napkins, Increments 2.5 cm 9 6b Observed Flame Lengths on Pet Film, Increments...Frequency of Extinguishment During Flame Spread 21 15 Flame Spread Velocity 21 VI 16 Flame Length Measured Parallel to the Surface 22 17 Comparison of... flame length (Lf) were measured from a video recording of the test. Despite erratic burn fronts with discontinuous flaming regions, the maximum

  12. Numerical approach to describe complementary drying of banana slices osmotically dehydrated

    NASA Astrophysics Data System (ADS)

    da Silva Júnior, Aluízio Freire; da Silva, Wilton Pereira; de Farias Aires, Juarez Everton; Farias Aires, Kalina Lígia C. A.

    2018-02-01

    In this work, diffusion model was used to describe the water loss in the complementary drying process of cylindrical slices of banana pretreated by osmotic dehydration. A numerical solution has been proposed for the diffusion equation in cylindrical coordinates, which was obtained through the Finite Volume Method. The diffusion equation was discretized assuming that the effective water diffusivity and the dimensions of a finite cylinder may vary; also considering the boundary condition of the third kind. The banana slices were cut in length of about 1.00 cm and average radius 1.70 cm before osmotic pretreatment, and completed the pretreatment with length of about 0.74 cm and average radius 1.40 cm. The complementary drying was carried out in a kiln with circulation and air exchange. Drying temperatures were the same as used in the osmotic pretreatment (40 to 70 °C). The proposed model described well the water loss, with good statistical indicators for all fits.

  13. Excitation-dependent carrier lifetime and diffusion length in bulk CdTe determined by time-resolved optical pump-probe techniques

    NASA Astrophysics Data System (ADS)

    Ščajev, Patrik; Miasojedovas, Saulius; Mekys, Algirdas; Kuciauskas, Darius; Lynn, Kelvin G.; Swain, Santosh K.; JarašiÅ«nas, Kestutis

    2018-01-01

    We applied time-resolved pump-probe spectroscopy based on free carrier absorption and light diffraction on a transient grating for direct measurements of the carrier lifetime and diffusion coefficient D in high-resistivity single crystal CdTe (codoped with In and Er). The bulk carrier lifetime τ decreased from 670 ± 50 ns to 60 ± 10 ns with increase of excess carrier density N from 1016 to 5 × 1018 cm-3 due to the excitation-dependent radiative recombination rate. In this N range, the carrier diffusion length dropped from 14 μm to 6 μm due to lifetime decrease. Modeling of in-depth (axial) and in-plane (lateral) carrier diffusion provided the value of surface recombination velocity S = 6 × 105 cm/s for the untreated surface. At even higher excitations, in the 1019-3 × 1020 cm-3 density range, D increase from 5 to 20 cm2/s due to carrier degeneracy was observed.

  14. Eye lens radiocarbon reveals centuries of longevity in the Greenland shark (Somniosus microcephalus).

    PubMed

    Nielsen, Julius; Hedeholm, Rasmus B; Heinemeier, Jan; Bushnell, Peter G; Christiansen, Jørgen S; Olsen, Jesper; Ramsey, Christopher Bronk; Brill, Richard W; Simon, Malene; Steffensen, Kirstine F; Steffensen, John F

    2016-08-12

    The Greenland shark (Somniosus microcephalus), an iconic species of the Arctic Seas, grows slowly and reaches >500 centimeters (cm) in total length, suggesting a life span well beyond those of other vertebrates. Radiocarbon dating of eye lens nuclei from 28 female Greenland sharks (81 to 502 cm in total length) revealed a life span of at least 272 years. Only the smallest sharks (220 cm or less) showed signs of the radiocarbon bomb pulse, a time marker of the early 1960s. The age ranges of prebomb sharks (reported as midpoint and extent of the 95.4% probability range) revealed the age at sexual maturity to be at least 156 ± 22 years, and the largest animal (502 cm) to be 392 ± 120 years old. Our results show that the Greenland shark is the longest-lived vertebrate known, and they raise concerns about species conservation. Copyright © 2016, American Association for the Advancement of Science.

  15. Monitoring Radionuclide Transport and Spatial Distribution with a 1D Gamma-Ray Scanner

    NASA Astrophysics Data System (ADS)

    Dozier, R.; Erdmann, B.; Sams, A.; Barber, K.; DeVol, T. A.; Moysey, S. M.; Powell, B. A.

    2016-12-01

    Understanding radionuclide movement in the environment is important for informing strategies for radioactive waste management and disposal. A 1-dimensional (1D) gamma-ray emission scanning system was developed to investigate radionuclide transport behavior within soils. Two case studies illustrate the use of the system for non-destructively monitoring transport processes within a soil column. The first case study explores the system capabilities for simultaneously detecting technetium-99m (99mTc), iodine-131 (131I), and sodium-22 (22Na) moving through a column (length = 14.1 cm, diameter = 3.8 cm) packed with soil from the Department of Energy's Savannah River Site. A sodium iodide (NaI) detector was placed at 4 cm above the influent and a Bismuth germanate (BGO) detector at about 10 cm above the influent. The NaI detector results show 99mTc, 131I, and 22Na having similar breakthrough curves with the tail of 99mTc being lower than that of 131I and 22Na. NaCl tracer results compliment the gamma-ray emission measurements. These results are promising because we are able to monitor movement of the isotopes in the column in real-time. In the second case study, the 1D gamma scanner was used to quantify radionuclide mobility within a lysimeter (length = 51 cm, diameter = 10 cm). A cementitious waste form containing cobalt-60 (60Co), barium-133 (133Ba), cesium-137 (137Cs), and europium-152 (152Eu), with the amount of each contained in the cement ranging from 3 to 8.5 MBq, was placed at the midpoint of the lysimeter. The lysimeter was then exposed to natural rainfall and environmental conditions and effluent samples were collected and quantified on a quarterly basis. Following 3.3 years of exposure, the radionuclide distribution in the lysimeter was quantified with a 0.64 cm collimated high-purity germanium gamma-ray spectrometer. Diffusion of 137Cs away from the cementitious wasteform was observed. No movement was seen for 133Ba, 60Co, or 152Eu within the detection limits of the spectrometer. An activity balance was used to quantify the detection efficiency of the spectrometer as a function of gamma-ray energy.

  16. Effect of the doped fibre length on soliton pulses of a bidirectional mode-locked fibre laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmad, H; Alwi Kutty, N A; Zulkifli, M Z

    A passively bidirectional mode-locked fibre laser is demonstrated using a highly concentrated erbium-doped fibre (EDF) as a gain medium. To accomplish mode-locked operation in a short cavity, use is made of carbon nanotubes (CNTs) as a saturable absorber. Soliton pulses are obtained at a wavelength of 1560 nm with a repetition rate ranging from 43.92 MHz to 46.97 MHz and pulse width stretching from 0.56 ps to 0.41 ps as the EDF length is reduced from 60 cm to 30 cm. (lasers)

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qin, Kun; Hu, Shuren; Retterer, Scott T.

    Our design, fabrication, and characterization of a label-free Mach–Zehnder interferometer (MZI) optical biosensor that incorporates a highly dispersive one-dimensional (1D) photonic crystal in one arm are presented. The sensitivity of this slow light MZI-based sensor scales with the length of the slow light photonic crystal region. The numerically simulated sensitivity of a MZI sensor with a 16 μm long slow light region is 115,000 rad/RIU-cm, which is sevenfold higher than traditional MZI biosensors with millimeter-length sensing regions. Moreover, the experimental bulk refractive index detection sensitivity of 84,000 rad/RIU-cm is realized and nucleic acid detection is also demonstrated.

  18. Association between patterns of maternal substance use and infant birth weight, length, and head circumference.

    PubMed

    Shankaran, Seetha; Das, Abhik; Bauer, Charles R; Bada, Henrietta S; Lester, Barry; Wright, Linda L; Smeriglio, Vincent

    2004-08-01

    To determine the effects of patterns of drug use during term pregnancy on infant growth parameters at birth. Histories of cocaine, opiate, alcohol, tobacco, and marijuana use during the 3-month period before pregnancy and the 3 trimesters of pregnancy were recorded at the infants' 1-month visit. Patterns of use were categorized as consistently high, moderate, or low/none or increasing/decreasing, and effects on growth parameters were analyzed in multivariate linear regression analyses, with adjustment for clinical site, maternal age, prepregnancy weight, multidrug use, and socioeconomic status. A total of 241 cocaine-exposed women and 410 non-cocaine-exposed women participated in the study. In the cocaine-exposed group, 75% used alcohol, 90% used tobacco, and 53% used marijuana; in the non-cocaine-exposed group, 57% used alcohol, 34% used tobacco, and 19% used marijuana. Birth weight, birth length, and head circumference were significantly greater among infants born to women who used no drugs, compared with women with any cocaine, opiate, alcohol, tobacco, or marijuana use, and were greater among infants born to cocaine nonusers, compared with cocaine users. With adjustment for confounders, birth weight was significantly affected by cocaine (deficit of 250 g with consistently low pattern) and tobacco (deficits of 232 g with consistently high pattern, 173 g with consistently moderate pattern, 153 g with decreasing pattern, and 103 g with consistently low pattern). Head size was affected by cocaine (deficit of 0.98 cm with consistently moderate pattern) and tobacco (deficits of 0.72 cm with consistently high pattern and 0.89 cm with consistently moderate pattern). Birth length was affected by tobacco use only (deficits of 0.82 cm with consistently high pattern and 0.98 cm with decreasing use). Patterns of tobacco use during pregnancy affect birth weight, length, and head circumference, whereas cocaine affects birth weight and head size, when adjustments are made for confounders, including multidrug use.

  19. [Effects of irrigation with different length micro-sprinkling hoses on soil water distribution, water consumption characteristics of winter wheat, and its grain yield].

    PubMed

    Man, Jian-guo; Wang, Dong; Yu, Zhen-wen; Zhang, Yong-li; Shi, Yu

    2013-08-01

    Taking the high-yielding winter wheat variety Jimai 22 as test material, a field experiment was conducted in 2010-2012 to study the effects of irrigation with different length micro-sprinkling hoses on the soil water distribution in winter wheat growth period and the water consumption characteristics and grain yield of winter wheat. Three micro-sprinkling hose lengths were designed, i. e., 40 m (T40), 60 m (T60) and 80 m (T80). Under the micro-sprinkling irrigation at jointing and anthesis stages, the uniformity of the horizontal distribution of irrigation water in soil increased significantly with the decrease of hose length from 80 to 40 m. When irrigated at jointing stage, the water content of 0-200 cm soil layer in each space of wheat rows had no significant difference within the 0-40 m distanced from the border initial in treatments T40 and T60. When measured at the 38-40 m, 58-60 m, and 78-80 m distanced from the border initial in treatment T80 at jointing and anthesis stages, the water content in 0-200 cm soil layer had the same change pattern, i. e., decreased with the increasing distance from micro-sprinkling hose. The water consumption amounts in 40-60 cm soil layer from jointing to anthesis stages and in 20-80 cm soil layer from anthesis to maturing stages were higher in treatment T40 than in treatments T60 and T80. However, the soil water consumption amount, irrigation amount at anthesis stage, total irrigation amount, and total water consumption amount were significantly lower in treatment T40 than in treatments T60 and T80. The grain yield, yield water use efficiency increased with the hose length decreased from 80 to 40 m, but the flow decreased. Therefore, the effective irrigation area per unit time decreased with the same irrigation amounts. Considering the grain yield, water use efficiency, and the flow through micro-sprinkling hose, 40 and 60 m were considered to be the appropriate micro-sprinkling hose lengths under this experimental condition.

  20. Effect of AgNO3 and BAP on Root as a Novel Explant in Date Palm (Phoenix dactylifera cv. Medjool) Somatic Embryogenesis.

    PubMed

    Roshanfekrrad, Marjan; Zarghami, Reza; Hassani, Hassan; Zakizadeh, Hedayat; Salari, Ali

    2017-01-01

    Somatic embryogenesis techniques are used for cloning a wide range of varieties of date palms around the world. The aim of the present study was to develop an efficient method with the lowest cost and the greatest potential to obtain in vitro plantlets of date palm cv. Medjool. Also, produce embryogenic callus and somatic embryos without using 2,4-dichlorophenoxyacetic acid (2,4-D). In this study, produced plantlets through somatic embryogenesis were used in vitro roots as explant cultured on Murashige and Skoog (MS) media containing three level of Silver Nitrate (AgNO3) (0, 3 and 6 mg L-1) plus two level of 6-benzylaminopurine (BAP) (0 and 2 mg L-1) plus 0.1 mg L-1 1-naphthylacetic acid (NAA) for callus induction. After 12 weeks of culture, callus induction and after 16 weeks, production of embryogenic callus and embryos were occurred from root explants. According to the results, medium containing 2 mg L-1 BAP and 3 mg L-1 silver nitrate+0.1 mg L-1 NAA showed the highest amount of embryogenic callus fresh weight (1.38 g). This treatment also cause the highest number and length of embryos by production of 90.04 embryogenic callus with length of 11.18 mm. On the other hand, shoots were appeared from germinated embryos and white roots began to appear within 8 weeks. Medium contains 3 mg L-1 BAP and 0.1 mg L-1 NAA with average of 12.27 cm shoot length and 15.48 cm root length was the best. Control treatment had the lowest average shoot (3.71 cm) and root (5.03 cm) length. This study showed that certain concentration of silver nitrate and BAP has stimulating effect on growth of produced embryonic callus from root segments of Medjool cultivar of date palm.

  1. The reliability of a newborn foot length measurement tool used by community volunteers to identify low birth weight or premature babies born at home in southern Tanzania.

    PubMed

    Marchant, Tanya; Penfold, Suzanne; Mkumbo, Elibariki; Shamba, Donat; Jaribu, Jennie; Manzi, Fatuma; Schellenberg, Joanna

    2014-08-20

    Low birthweight babies need extra care, and families need to know whether their newborn is low birthweight in settings where many births are at home and weighing scales are largely absent. In the context of a trial to improve newborn health in southern Tanzania, a counselling card was developed that incorporated a newborn foot length measurement tool to screen newborns for low birth weight and prematurity. This was used by community volunteers at home visits and shows a scale picture of a newborn foot with markers for a 'short foot' (<8 cm). The tool built on previous hospital based research that found newborn foot length <8 cm to have sensitivity and specificity to identify low birthweight (<2500 g) of 87% and 60% respectively. Reliability of the tool used by community volunteers to identify newborns with short feet was tested. Between July-December 2010 a researcher accompanied volunteers to the homes of babies younger than seven days and conducted paired measures of newborn foot length using the counselling card tool and using a plastic ruler. Intra-method reliability of foot length measures was assessed using kappa scores, and differences between measurers were analysed using Bland and Altman plots. 142 paired measures were conducted. The kappa statistic for the foot length tool to classify newborns as having small feet indicated that it was moderately reliable when applied by volunteers, with a kappa score of 0.53 (95% confidence interval 0.40 - 0.66) . Examination of differences revealed that community volunteers systematically underestimated the length of newborn feet compared to the researcher (mean difference -0.26 cm (95% confidence interval -0.31-0.22), thus overestimating the number of newborns needing extra care. The newborn foot length tool used by community volunteers to identify small babies born at home was moderately reliable in southern Tanzania where a large number of births occur at home and scales are not available. Newborn foot length is not the best anthropometric proxy for birthweight but was simple to implement at home in the first days of life when the risk of newborn death is highest.

  2. Biodegradation of toluene by a lab-scale biofilter inoculated with Pseudomonas putida DK-1.

    PubMed

    Park, D W; Kim, S S; Haam, S; Ahn, I S; Kim, E B; Kim, W S

    2002-03-01

    The biodegradation of toluene by biofiltration inoculated with Pseudomonas putida DK-1 was investigated with variation of the several environmental parameters, such as temperature, bed length, gas flow rate and optimal humidity zone. The optimal temperature range to treat toluene gas was found to be 32-35 degrees C. Increasing the gas flow rate showed an inverse effect on the elimination capacity and the removal efficiency. The optimal gas flow rate was obtained at 65 ml min(-1) from the relation between the removal efficiency and the elimination capacity. The biodegradation rate of the toluene with respect to the bed lengths (3, 6, 9, 12 and 15 cm) increased up to 80 h but was then independent of the bed lengths after 80 h except for the 3 cm bed length. The elimination capacity was improved by about 70% compared with that reported in other literature and was also in agreement with theoretical models.

  3. Global geodesy using GPS without fiducial sites

    NASA Technical Reports Server (NTRS)

    Heflin, Michael; Bertiger, Willy; Blewitt, Geoff; Freedman, Adam; Hurst, Ken; Lichten, Steve; Lindqwister, Ulf; Vigue, Yvonne; Webb, Frank; Yunck, Tom

    1992-01-01

    Baseline lengths and geocentric radii have been determined from GPS data without the use of fiducial sites. Data from the first GPS experiment for the IERS and Geodynamics (GIG '91) have been analyzed with a no-fiducial strategy. A baseline length daily repeatability of 2 mm + 4 parts per billion was obtained for baselines in the Northern Hemisphere. Comparison of baseline lengths from GPS and the global VLBI solution GLB659 (Caprette et al. 1990) show rms agreement of 2.1 parts per billion. The geocentric radius mean daily repeatability for all sites was 15 cm. Comparison of geocentric radii from GPS and SV5 (Murray et al. 1990) show rms agreement of 3.8 cm. Given n globally distributed stations, the n(n - 1)/2 baseline lengths and n geocentric radii uniquely define a rigid closed polyhedron with a well-defined center of mass. Geodetic information can be obtained by examining the structure of the polyhedron and its change with time.

  4. Effect of sieving polymer concentration on separation of 100 bp DNA Ladder by capillary gel electrophoresis

    NASA Astrophysics Data System (ADS)

    Nakazumi, T.; Hara, Y.

    2017-09-01

    We studied the effect of sieving polymer concentration on separation of a 100 bp DNA Ladder by capillary gel electrophoresis (CGE) using hydroxyethyl cellulose (HEC) with a molecular size of 1000 k. For measurement purposes, we selected a fused silica capillary with total length of 15 cm and effective length of 7.5 cm; this was applied to compact CGE equipment for a Point-Care-Testing (POCT) system. Measurement results of the 100 bp DNA Ladder sample indicated that small DNA separation was significantly affected by HEC sieving polymer concentration. This was due to the level of entanglement between small DNA molecules and the sieving polymer chain significantly influencing migration time, mobility, and resolution length of the CGE process. We concluded that 1.0 w/v % HEC sieving polymer concentration was optimal for CGE separation of DNA ≥1000bp in the 100 bp DNA Ladder (100-1500 bp) when using the short-length capillary.

  5. Size of testes, ovaries, uterus and breast buds by ultrasound in healthy full-term neonates ages 0–3 days

    PubMed Central

    Kaplan, SL; Edgar, JC; Ford, EG; Adgent, MA; Schall, JI; Kelly, A; Umbach, DM; Rogan, WJ; Stallings, VA; Darge, K

    2017-01-01

    Background Hormonally-sensitive organs in the neonate can change size within days of birth as circulating maternal estrogen wanes. Although several reports document the size of these organs through infancy, few focus on the near-birth period. Clinical and research evaluation of hormonal and genitourinary disorders would benefit from reference size standards. Objective We describe the size of the uterus, ovaries, testes, and breast buds in healthy term neonates. Materials and Methods As part of the Infant Feeding and Early Development (IFED) study, we sonographically measured the largest diameter of these organs in sagittal, transverse, and anterior-posterior planes for 194 female and 204 male newborns up to 3 days old. We calculated mean, median, and percentiles for longest axis length and for volume calculated from measured diameters. We evaluated size differences by laterality, sex, and race and compared our observations to published values. Results Mean length and volume, respectively, were: uterus, 4.2 cm and 10.0 cm3; ovary, 1.0 cm and 0.2 cm3; testis, 1.1 cm and 0.3 cm3 (0.4 cm3 Lambert volume); female breast bud, 1.2 cm and 0.7 cm3; male breast bud, 1.1 cm and 0.6 cm3. Breast buds were larger in females than males. Laterality differences were typically below the precision of clinical measurement. No significant race differences were detected. Conclusion Using data from our large cohort together with published values, we provide guidelines for evaluating the size of reproductive organs within the first 3 days of life. Discrepancies between our results and published values are likely attributable to technique. PMID:27580909

  6. Development of a New Growth Standard for Breastfed Chinese Infants: What Is the Difference from the WHO Growth Standards?

    PubMed

    Huang, Xiaona; Chang, Jenjen; Feng, Weiwei; Xu, Yiqun; Xu, Tao; Tang, He; Wang, Huishan; Pan, Xiaoping

    2016-01-01

    The objectives of this longitudinal study were to examine the trajectory of breastfed infants' growth in China to update growth standards for early childhood, and to compare these updated Chinese growth standards with the growth standards recommended by the World Health Organization (WHO) in 2006.This longitudinal cohort study enrolled 1,840 healthy breastfed infants living in an "optimal" environment favorable to growth and followed up until one year of age from 2007 to 2010. The study subjects were recruited from 60 communities in twelve cities in China. A participating infant's birth weight was measured within the first hour of the infant's life, and birth length and head circumference within 24 hours after birth. Repeated weekly and monthly anthropometric measurements were also taken. Multilevel (ML) modelling via MLwiN2.25 was fitted to estimate the growth curves of weight-for-age (WFA), length-for-age (LFA), and head circumference-for-age (HFA) for the study sample as a whole and by child sex, controlling for mode of delivery, the gravidity and parity of the mother, infant's physical measurements at birth, infant's daily food intaking frequency per day, infant's medical conditions, the season when the infant's physical measurement was taken, parents' ages, heights, and attained education, and family structure and income per month. During the first four weeks after birth, breastfed infants showed an increase in weight, length, and head circumference of 1110g, 4.9 cm, and 3.2 cm, respectively, among boys, and 980 g, 4.4 cm, and 2.8 cm, respectively, among girls. Throughout infancy, the total growth for these three was 6930 g, 26.4 cm, and 12.5 cm, respectively, among boys, and 6480 g, 25.5 cm, and 11.7 cm, respectively, among girls. As expected, there was a significant sex difference in growth during the first year. In comparison with the WHO growth standards, breastfed children in our study were heavier in weight, longer in length, and bigger in head circumference, with the exception of a few age points during the first two to four months on the upper two percentile curves.Our data suggested the growth curves for breastfed infants in China were significantly different in comparison with those based on the WHO standards. The adoption of the WHO infant growth standards among Chinese infants, as well as the methods used in the development of such growth standards in China, need careful and coordinated consideration.

  7. Development of a New Growth Standard for Breastfed Chinese Infants: What Is the Difference from the WHO Growth Standards?

    PubMed Central

    Chang, Jenjen; Feng, Weiwei; Xu, Yiqun; Xu, Tao; Tang, He; Wang, Huishan; Pan, Xiaoping

    2016-01-01

    The objectives of this longitudinal study were to examine the trajectory of breastfed infants’ growth in China to update growth standards for early childhood, and to compare these updated Chinese growth standards with the growth standards recommended by the World Health Organization (WHO) in 2006.This longitudinal cohort study enrolled 1,840 healthy breastfed infants living in an "optimal" environment favorable to growth and followed up until one year of age from 2007 to 2010. The study subjects were recruited from 60 communities in twelve cities in China. A participating infant’s birth weight was measured within the first hour of the infant’s life, and birth length and head circumference within 24 hours after birth. Repeated weekly and monthly anthropometric measurements were also taken. Multilevel (ML) modelling via MLwiN2.25 was fitted to estimate the growth curves of weight-for-age (WFA), length-for-age (LFA), and head circumference-for-age (HFA) for the study sample as a whole and by child sex, controlling for mode of delivery, the gravidity and parity of the mother, infant’s physical measurements at birth, infant’s daily food intaking frequency per day, infant’s medical conditions, the season when the infant’s physical measurement was taken, parents’ ages, heights, and attained education, and family structure and income per month. During the first four weeks after birth, breastfed infants showed an increase in weight, length, and head circumference of 1110g, 4.9 cm, and 3.2 cm, respectively, among boys, and 980 g, 4.4 cm, and 2.8 cm, respectively, among girls. Throughout infancy, the total growth for these three was 6930 g, 26.4 cm, and 12.5 cm, respectively, among boys, and 6480 g, 25.5 cm, and 11.7 cm, respectively, among girls. As expected, there was a significant sex difference in growth during the first year. In comparison with the WHO growth standards, breastfed children in our study were heavier in weight, longer in length, and bigger in head circumference, with the exception of a few age points during the first two to four months on the upper two percentile curves.Our data suggested the growth curves for breastfed infants in China were significantly different in comparison with those based on the WHO standards. The adoption of the WHO infant growth standards among Chinese infants, as well as the methods used in the development of such growth standards in China, need careful and coordinated consideration. PMID:27977706

  8. A new analysis method using Bragg curve spectroscopy for a Multi-purpose Active-target Particle Telescope for radiation monitoring

    NASA Astrophysics Data System (ADS)

    Losekamm, M. J.; Milde, M.; Pöschl, T.; Greenwald, D.; Paul, S.

    2017-02-01

    Traditional radiation detectors can either measure the total radiation dose omnidirectionally (dosimeters), or determine the incoming particles characteristics within a narrow field of view (spectrometers). Instantaneous measurements of anisotropic fluxes thus require several detectors, resulting in bulky setups. The Multi-purpose Active-target Particle Telescope (MAPT), employing a new detection principle, is designed to measure particle fluxes omnidirectionally and be simultaneously a dosimeter and spectrometer. It consists of an active core of scintillating fibers whose light output is measured by silicon photomultipliers, and fits into a cube with an edge length of 10 cm. It identifies particles using extended Bragg curve spectroscopy, with sensitivity to charged particles with kinetic energies above 25 MeV. MAPT's unique layout results in a geometrical acceptance of approximately 800 cm2 sr and an angular resolution of less than 6°, which can be improved by track-fitting procedures. In a beam test of a simplified prototype, the energy resolution was found to be less than 1 MeV for protons with energies between 30 and 70 MeV. Possible applications of MAPT include the monitoring of radiation environments in spacecraft and beam monitoring in medical facilities.

  9. Measurements and FLUKA simulations of bismuth and aluminium activation at the CERN Shielding Benchmark Facility (CSBF)

    NASA Astrophysics Data System (ADS)

    Iliopoulou, E.; Bamidis, P.; Brugger, M.; Froeschl, R.; Infantino, A.; Kajimoto, T.; Nakao, N.; Roesler, S.; Sanami, T.; Siountas, A.

    2018-03-01

    The CERN High Energy AcceleRator Mixed field facility (CHARM) is located in the CERN Proton Synchrotron (PS) East Experimental Area. The facility receives a pulsed proton beam from the CERN PS with a beam momentum of 24 GeV/c with 5 ṡ1011 protons per pulse with a pulse length of 350 ms and with a maximum average beam intensity of 6.7 ṡ1010 p/s that then impacts on the CHARM target. The shielding of the CHARM facility also includes the CERN Shielding Benchmark Facility (CSBF) situated laterally above the target. This facility consists of 80 cm of cast iron and 360 cm of concrete with barite concrete in some places. Activation samples of bismuth and aluminium were placed in the CSBF and in the CHARM access corridor in July 2015. Monte Carlo simulations with the FLUKA code have been performed to estimate the specific production yields for these samples. The results estimated by FLUKA Monte Carlo simulations are compared to activation measurements of these samples. The comparison between FLUKA simulations and the measured values from γ-spectrometry gives an agreement better than a factor of 2.

  10. Design and fabrication of segmented-in-series solid oxide fuel cells

    NASA Astrophysics Data System (ADS)

    Lai, Tammy S.

    Segmented-in-series solid oxide fuel cells (SS-SOFC) consist of several thick film cells deposited onto a porous, flattened tubular substrate. SS-SOFCs have a reduced need for gas-tight seals relative to planar SOFCs and can have a short current path compared to tubular SOFCs, limiting electrode ohmic resistance. Like tubular SOFCs, SS-SOFCs are suitable for stationary power generation. Their potentially small cell size makes them candidates for portable applications as well. The goals of this thesis project were to develop SS-SOFCs with 1-2 mm cell lengths and to analyze the effects of cell geometry and support current shunting on performance. Standard SOFC materials were chosen for the active components: yttria stabilized zirconia (YSZ) electrolyte; Ni-YSZ cermet anode; and (La,Sr)MnO 3-based cathode. A Pt-YSZ cermet was used as the interconnect material. Screen printing was the deposition method for all layers due to its low cost and patterning ability. A power density of >900 mW/cm2 was achieved with a cathode sheet resistance of ≈3 O/□ (≈90 mum LSM thickness). A D-optimal study was conducted to find processing conditions yielding substrates with ≥30 vol% porosity and high strength. Uniaxially pressed partially stabilized zirconia (PSZ) with 15 wt% starch pore former met the requirements, though 20 wt% graphite pore former was later found to give a smoother surface that improved screen printed layer quality. Calculations presented in this thesis take into account losses due to cell resistances, electrode ohmic resistances, interconnect resistance, and shunting by a weakly-conductive support material. Power density was maximized at an optimal cell length---it decreased at larger cell lengths due to electrode lateral resistance loss and at smaller cell lengths due to a decreasing fraction of cell active area. Assuming dimensions expected for screen printing and typical area specific resistances (RAS), optimal cell lengths typically ranged from 1 to 3 mm. The calculated and experimental values for the array RAS (active and inactive areas) showed similar dependences on cathode sheet resistance. The impact of shunting current increased with decreasing cell lengths. Shunting current was predicted to decrease array current by ˜10% for a 1.5 mm active cell length, though experimental measurements suggest that the calculation may overestimate the shunting effect.

  11. Determination of vanillin in vanilla perfumes and air by capillary electrophoresis.

    PubMed

    Minematsu, Saaya; Xuan, Guang-Shan; Wu, Xing-Zheng

    2013-12-01

    The present study investigated capillary electrophoretic detection of vanillin in vanilla perfume and air. An UV-absorbance detector was used in a home-made capillary electrophoretic instrument. A fused silica capillary (outer diameter: 364 μm, inner diameter: 50 μm) was used as a separation capillary, and a high electric voltage (20 kV) was applied across the two ends of the capillary. Total length of the capillary was 70 cm, and the effective length was 55 cm. Experimental results showed that the vanillin peak was detected at about 600, 450, and 500 seconds when pH of running buffers in CE were 7.2, 9.3, and 11.5, respectively. The peak area of vanillin was proportional to its concentration in the range of 0-10(-2) mol/L. The detection limit was about 10(-5) mol/L. Vanillin concentration in a 1% vanilla perfume sample was determined to be about 3×10(-4) mol/L, agreed well with that obtained by a HPLC method. Furthermore, determination of vanillin in air by combination of CE and active carbon adsorption method was investigated. Copyright © 2013 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  12. Reliability of anthropometric measurements in young male and female artistic gymnasts.

    PubMed

    Siatras, Theophanis; Skaperda, Malamati; Mameletzi, Dimitra

    2010-12-01

    Body dimensions and body composition of children participating in artistic activities, such as gymnastics and many types of dancing, are important factors in performance improvement. The present study aimed to determine the reliability of a series of selected anthropometric measurements in young male and female gymnasts. Segment lengths, body breadths, circumferences, and skinfold thickness were measured in 20 young gymnasts by the same experienced examiner, using portable and easy-to-use instruments. All parameters were measured twice (test-retest) under the same conditions within a week's period. The high intra-class correlation coefficient (ICC) values ranging from 0.87 to 0.99, as well as the low coefficient of variation (CV) values (<5.3%), affirmed that the selected measurements were highly reliable. The technical error of measurement (TEM) values for lengths and breadths were 0.15 to 0.80 cm, for circumferences 0.22 to 1 cm, and for skinfold thickness 0.33 to 0.58 mm. The high test-retest ICC and the low CV and TEM values confirmed the reliability of all anthropometric measurements in young artistic gymnasts. Therefore, these measurements could contribute to further research in this field of investigation, helping to monitor young artistic gymnasts' growth status and identify specific characteristics for increased performance in this sport.

  13. Electrochemically oxidized electronic and ionic conducting nanostructured block copolymers for lithium battery electrodes.

    PubMed

    Patel, Shrayesh N; Javier, Anna E; Balsara, Nitash P

    2013-07-23

    Block copolymers that can simultaneously conduct electronic and ionic charges on the nanometer length scale can serve as innovative conductive binder material for solid-state battery electrodes. The purpose of this work is to study the electronic charge transport of poly(3-hexylthiophene)-b-poly(ethylene oxide) (P3HT-PEO) copolymers electrochemically oxidized with lithium bis(trifluoromethanesulfonyl) imide (LiTFSI) salt in the context of a lithium battery charge/discharge cycle. We use a solid-state three-terminal electrochemical cell that enables simultaneous conductivity measurements and control over electrochemical doping of P3HT. At low oxidation levels (ratio of moles of electrons removed to moles of 3-hexylthiophene moieties in the electrode), the electronic conductivity (σe,ox) increases from 10(-7) S/cm to 10(-4) S/cm. At high oxidation levels, σe,ox approaches 10(-2) S/cm. When P3HT-PEO is used as a conductive binder in a positive electrode with LiFePO4 active material, P3HT is electrochemically active within the voltage window of a charge/discharge cycle. The electronic conductivity of the P3HT-PEO binder is in the 10(-4) to 10(-2) S/cm range over most of the potential window of the charge/discharge cycle. This allows for efficient electronic conduction, and observed charge/discharge capacities approach the theoretical limit of LiFePO4. However, at the end of the discharge cycle, the electronic conductivity decreases sharply to 10(-7) S/cm, which means the "conductive" binder is now electronically insulating. The ability of our conductive binder to switch between electronically conducting and insulating states in the positive electrode provides an unprecedented route for automatic overdischarge protection in rechargeable batteries.

  14. Rod Photopigment Kinetics After Photodisruption of the Retinal Pigment Epithelium

    PubMed Central

    Masella, Benjamin D.; Hunter, Jennifer J.; Williams, David R.

    2014-01-01

    Purpose. Advances in retinal imaging have led to the discovery of long-lasting retinal changes caused by light exposures below published safety limits, including disruption of the RPE. To investigate the functional consequences of RPE disruption, we combined adaptive optics ophthalmoscopy with retinal densitometry. Methods. A modified adaptive optics scanning light ophthalmoscope (AOSLO) measured the apparent density and regeneration rate of rhodopsin in two macaques before and after four different 568-nm retinal radiant exposures (RREs; 400–3200 J/cm2). Optical coherence tomography (OCT) was used to measure the optical path length through the photoreceptor outer segments before and after RPE disruption. Results. All tested RREs caused visible RPE disruption. Apparent rhodopsin density was significantly reduced following 1600 (P = 0.01) and 3200 J/cm2 (P = 0.007) exposures. No significant change in apparent density was observed in response to 800 J/cm2. Surprisingly, exposure to 400 J/cm2 showed a significant increase in apparent density (P = 0.047). Rhodopsin recovery rate was not significantly affected by these RREs. Optical coherence tomography measurements showed a significant decrease in the optical path length through the photoreceptor outer segments for RREs above 800 J/cm2 (P < 0.001). Conclusions. At higher RREs, optical path length through the outer segments was reduced. However, the rate of photopigment regeneration was unchanged. While some ambiguity remains as to the correlation between measured reflectivity and absolute rhodopsin density; at the lowest RREs, RPE disruption appears not to be accompanied by a loss of apparent rhodopsin density, which would have been indicative of functional loss. PMID:25316724

  15. Dorsal Phalloplasty to Preserve Penis Length after Penile Prosthesis Implantation

    PubMed Central

    Shaeer, Osama; Shaeer, Kamal; Rahman, Islam A.

    2017-01-01

    Objectives Following penile prosthesis implantation (PPI), patients may complain of a decrease in visible penis length. A dorsal phalloplasty defines the penopubic junction by tacking pubic skin to the pubis, revealing the base of the penis. This study aimed to evaluate the efficacy of a dorsal phalloplasty in increasing the visible penis length following PPI. Methods An inflatable penile prosthesis was implanted in 13 patients with severe erectile dysfunction (ED) at the Kamal Shaeer Hospital, Cairo, Egypt, from January 2013 to May 2014. During the surgery, nonabsorbable tacking sutures were used to pin the pubic skin to the pubis through the same penoscrotal incision. Intraoperative penis length was measured before and after the dorsal phalloplasty. Overall patient satisfaction was measured on a 5-point rating scale and patients were requested to subjectively compare their postoperative penis length with memories of their penis length before the onset of ED. Results Intraoperatively, the dorsal phalloplasty increased the visible length of the erect penis by an average of 25.6%. The average length before and after tacking was 10.2 ± 2.9 cm and 13.7 ± 2.8 cm, respectively (P <0.002). Postoperatively, seven patients (53.8%) reported a longer penis, five patients (38.5%) reported no change in length and one patient (7.7%) reported a slightly shorter penis. The mean overall patient satisfaction score was 4.9 ± 0.3. None of the patients developed postoperative complications. Conclusion A dorsal phalloplasty during PPI is an effective method of increasing visible penis length, therefore minimising the impression of a shorter penis after implantation. PMID:28417025

  16. Plantar fascia coronal length: a new parameter for plantar fascia assessment.

    PubMed

    Sari, Ahmet Sinan; Demircay, Emre; Cakmak, Gokhan; Sahin, M Sukru; Tuncay, I Cengiz; Altun, Suleyman

    2015-01-01

    The effects of gender and various anthropometric variables were previously reported as significant predictors of plantar fascia thickness. Although a strong correlation between either the body weight or body mass index (BMI) and plantar fascia thickness were not demonstrated, a moderate relation was stated. We retrospectively investigated the role of gender, height, weight, and body mass index on plantar fascia thickness at the calcaneal origin (PFCO) and 1 cm distal from the calcaneal origin (PF1cm) and the coronal length of the plantar fascia at the calcaneal origin (CLPF) in healthy subjects. The PFCO, PF1cm, and CLPF were retrospectively measured from magnetic resonance images of 100 healthy subjects. The gender, height, weight, and body mass index of the participants were also noted. Gender was a predictive factor for the length of the CLPF. The subjects with a BMI >25 kg/m(2) had a significantly greater PFCO, PF1cm, and CLPF. Height was mildly and BMI and weight were moderately related to the PFCO. However the CLPF showed a better correlation with height, BMI, and weight than that of plantar fascia thickness. CLPF better reflected the role of weight, BMI, and height than its thickness. It is a new parameter that could be valuable in the evaluation of plantar fascia disorders. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Reproduction and growth of the painted comber Serranus scriba (Serranidae) of the Marine Reserve of Lanzarote Island (Central-Eastern Atlantic)

    NASA Astrophysics Data System (ADS)

    Tuset, V. M.; García-Díaz, M. M.; González, J. A.; Lorente, M. J.; Lozano, I. J.

    2005-08-01

    The population biology of painted comber Serranus scriba (Linnaeus, 1758) of the Canary Islands coast was studied to estimate gonad morphology, sexuality, age and growth. Analysis of gonad organization and development revealed that it is a functional simultaneous hermaphrodite. Its anatomy and growth pattern of the reproductive cells is similar to that described in other species of the genus Serranus, although the sequence of vesicles appearing varies during vitellogenesis. Spawning season occurred from January to September with a peak in June. Individuals reached 50% maturity at 17.3 cm TL and 95% at 22.7 cm TL. Length-weight relationship was described by the following parameters: a = 0.01 and b = 3.10, being allometric positive. Age was determined from annuli in whole forming an opaque zone and a translucent zone in each annulus per year. The high percentage of otoliths with translucent zone during the annual cycle indicated that this species presents continuous growth throughout the year. Age range was 2-11 years for fish measuring 15.0-29.4 cm TL. This species is slow-growing and long lived. The growth parameters obtained were L∞ = 34.18 cm TL, k = 0.13 years -1, and to = -2.50 years. Otolith length was the best predictor of fish length, while the otolith weight was the best predictor of age.

  18. Comparative Dispositions of Ofloxacin in Human Head, Axillary, and Pubic Hairs

    PubMed Central

    Kosuge, Kazuhiro; Uematsu, Toshihiko; Araki, Sei-Ichi; Matsuno, Hiroyuki; Ohashi, Kyoichi; Nakashima, Mitsuyoshi

    1998-01-01

    The distribution of ofloxacin (OFLX) along the shaft of each of three hair types, i.e., head, axillary and pubic, was investigated and compared among five healthy male volunteers 1 to 4 months after ingestion of OFLX for 1 or 2 days (total dose, 200 or 600 mg). Five strands of each hair type were sectioned together into successive 0.5-cm lengths starting from the dermal end, over a length of ≤6 cm, and the OFLX concentration in each hair section was measured by high-pressure liquid chromatography with fluorescence detection. The distribution of OFLX along the head hair shaft was narrow, having a single peak even 3 to 4 months after administration, suggesting a rather uniform growth rate among hair strands. On the other hand, the OFLX distribution along axillary or pubic hair shafts tended to be broad, even having two apparent peaks, and the growth rate did not seem uniform. Since axillary hair seemed to stop growing after having gained a length of ≤4 to 5 cm, it was suggested to enter a resting stage after the growth of ≤3 cm over the 2 to 4 months after OFLX incorporation. These findings indicate that head hair is the most suitable for analysis of individual drug use and the larger growth rate and cycle stage variabilities of strands of the other types of hair should be taken into account. PMID:9593174

  19. Comparative dispositions of ofloxacin in human head, axillary, and pubic hairs.

    PubMed

    Kosuge, K; Uematsu, T; Araki, S I; Matsuno, H; Ohashi, K; Nakashima, M

    1998-05-01

    The distribution of ofloxacin (OFLX) along the shaft of each of three hair types, i.e., head, axillary and pubic, was investigated and compared among five healthy male volunteers 1 to 4 months after ingestion of OFLX for 1 or 2 days (total dose, 200 or 600 mg). Five strands of each hair type were sectioned together into successive 0.5-cm lengths starting from the dermal end, over a length of < or = 6 cm, and the OFLX concentration in each hair section was measured by high-pressure liquid chromatography with fluorescence detection. The distribution of OFLX along the head hair shaft was narrow, having a single peak even 3 to 4 months after administration, suggesting a rather uniform growth rate among hair strands. On the other hand, the OFLX distribution along axillary or pubic hair shafts tended to be broad, even having two apparent peaks, and the growth rate did not seem uniform. Since axillary hair seemed to stop growing after having gained a length of < or = 4 to 5 cm, it was suggested to enter a resting stage after the growth of < or = 3 cm over the 2 to 4 months after OFLX incorporation. These findings indicate that head hair is the most suitable for analysis of individual drug use and the larger growth rate and cycle stage variabilities of strands of the other types of hair should be taken into account.

  20. Laboratory trials of fatty acids as repellents or antifeedants against houseflies, horn flies and stable flies (Diptera: Muscidae).

    PubMed

    Mullens, Bradley A; Reifenrath, William G; Butler, Sarah M

    2009-12-01

    Straight-chain, saturated fatty acids (particularly C8, C9 and C10) have some known behavioral effects on insects such as mosquitoes, and were tested in combination for potential repellency/antifeedant activity in bioassays against three significant muscoid flies of medical/veterinary importance: houseflies, horn flies and stable flies. Mixtures of C8, C9 and C10 (1:1:1; 15% total actives in formulation) were highly repellent to houseflies and horn flies at or below 1 mg formulation cm(-2). Repellency time varied from < 1 day for houseflies to usually at least 3 days for horn flies. Individual longer-chain-length fatty acids were tested, and C11 repelled houseflies for up to 5-8 days, while C12 lasted 2 days. Minimum statistically significant repellency levels of the C8, C9 and C10 mixture (3 h after application) against horn flies were 0.06-0.12 mg cm(-2). A liquid formulation of the 15% C8, C9 and C10 mixture in a silicone oil carrier (at 2.8 mg AI cm(-2)) was highly repellent against hungry stable flies in a blood-feeding membrane bioassay for at least 8 h. The low toxicity and reasonable activity and persistence of these carboxylic acids make them good candidates for development as protective materials against pest flies in livestock settings. (c) 2009 Society of Chemical Industry.

  1. Stick balancing with reflex delay in case of parametric forcing

    NASA Astrophysics Data System (ADS)

    Insperger, Tamas

    2011-04-01

    The effect of parametric forcing on a PD control of an inverted pendulum is analyzed in the presence of feedback delay. The stability of the time-periodic and time-delayed system is determined numerically using the first-order semi-discretization method in the 5-dimensional parameter space of the pendulum's length, the forcing frequency, the forcing amplitude, the proportional and the differential gains. It is shown that the critical length of the pendulum (that can just be balanced against the time-delay) can significantly be decreased by parametric forcing even if the maximum forcing acceleration is limited. The numerical analysis showed that the critical stick length about 30 cm corresponding to the unforced system with reflex delay 0.1 s can be decreased to 18 cm with keeping maximum acceleration below the gravitational acceleration.

  2. Effects of arbuscular mycorrhizal fungi on seedling growth and development of two wetland plants, Bidens frondosa L., and Eclipta prostrata (L.) L., grown under three levels of water availability.

    PubMed

    Stevens, Kevin J; Wall, Christopher B; Janssen, Joel A

    2011-05-01

    To identify the importance of arbuscular mycorrhizal fungi (AMF) colonizing wetland seedlings following flooding, we assessed the effects of AMF on seedling establishment of two pioneer species, Bidens frondosa and Eclipta prostrata grown under three levels of water availability and ask: (1) Do inoculated seedlings differ in growth and development from non-inoculated plants? (2) Are the effects of inoculation and degree of colonization dependent on water availability? (3) Do plant responses to inoculation differ between two closely related species? Inoculation had no detectable effects on shoot height, or plant biomass but did affect biomass partitioning and root morphology in a species-specific manner. Shoot/root ratios were significantly lower in non-inoculated E. prostrata plants compared with inoculated plants (0.381 ± 0.066 vs. 0.683 ± 0.132). Root length and surface area were greater in non-inoculated E. prostrata (259.55 ± 33.78 cm vs. 194.64 ± 27.45 cm and 54.91 ± 7.628 cm(2) vs. 46.26 ± 6.8 cm(2), respectively). Inoculation had no detectable effect on B. frondosa root length, volume, or surface area. AMF associations formed at all levels of water availability. Hyphal, arbuscular, and vesicular colonization levels were greater in dry compared with intermediate and flooded treatments. Measures of mycorrhizal responsiveness were significantly depressed in E. prostrata compared with B. frondosa for total fresh weight (-0.3 ± 0.18 g vs. 0.06 ± 0.06 g), root length (-0.78 ± 0.28 cm vs.-0.11 ± 0.07 cm), root volume (-0.49 ± 0.22 cm(3) vs. 0.06 ± 0.07 cm(3)), and surface area (-0.59 ± 0.23 cm(2) vs.-0.03 ± 0.08 cm(2)). Given the disparity in species response to AMF inoculation, events that alter AMF prevalence in wetlands could significantly alter plant community structure by directly affecting seedling growth and development.

  3. Micro-computed Tomographic Analysis of Apical Microcracks before and after Root Canal Preparation by Hand, Rotary, and Reciprocating Instruments at Different Working Lengths.

    PubMed

    de Oliveira, Bruna Paloma; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Heck, Richard John; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes

    2017-07-01

    This study aimed to compare apical microcrack formation after root canal shaping by hand, rotary, and reciprocating files at different working lengths using micro-computed tomographic analysis. Sixty mandibular incisors were randomly divided into 6 experimental groups (n = 10) according to the systems and working lengths used for the root canal preparation: ProTaper Universal for Hand Use (Dentsply Maillefer, Ballaigues, Switzerland), HyFlex CM (Coltene-Whaledent, Allstetten, Switzerland), and Reciproc (VDW, Munich, Germany) files working at the apical foramen (AF) and 1 mm short of the AF (AF - 1 mm). The teeth were imaged with micro-computed tomographic scanning at an isotropic resolution of 14 μm before and after root canal preparation, and the cross-sectional images generated were assessed to detect microcracks in the apical portion of the roots. Overall, 17 (28.3%) specimens presented microcracks before instrumentation. Apical microcracks were present in 1 (ProTaper Universal for Hand Use), 3 (Hyflex CM), and 2 (Reciproc) specimens when the instrumentation terminated at the AF. When instrumentation was terminated at AF - 1 mm, apical microcracks were detected in 3 (ProTaper Universal for Hand Use) and 4 (Hyflex CM and Reciproc) specimens. All these microcracks detected after root canal preparation were already present before instrumentation, and no new apical microcrack was visualized. For all groups, the number of slices presenting microcracks after root canal preparation was the same as before canal preparation. Root canal shaping with ProTaper Universal for Hand Use, HyFlex CM, and Reciproc systems, regardless of the working length, did not produce apical microcracks. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Development of a 1-m plasma source for heavy ion beam charge neutralization

    NASA Astrophysics Data System (ADS)

    Efthimion, Philip C.; Gilson, Erik P.; Grisham, Larry; Davidson, Ronald C.; Yu, Simon; Waldron, William; Grant Logan, B.

    2005-05-01

    Highly ionized plasmas are being employed as a medium for charge neutralizing heavy ion beams in order to focus to a small spot size. Calculations suggest that plasma at a density of 1-100 times the ion beam density and at a length ˜0.1-1 m would be suitable for achieving a high level of charge neutralization. A radio frequency (RF) source was constructed at the Princeton Plasma Physics Laboratory (PPPL) in support of the joint Neutralized Transport Experiment (NTX) at the Lawrence Berkeley National Laboratory (LBNL) to study ion beam neutralization. Pulsing the source enabled operation at pressures ˜10 -6 Torr with plasma densities of 10 11 cm -3. Near 100% ionization was achieved. The plasma was 10 cm in length, but future experiments require a source 1 m long. The RF source does not easily scale to the length. Consequently, large-volume plasma sources based upon ferroelectric ceramics are being considered. These sources have the advantage of being able to increase the length of the plasma and operate at low neutral pressures. The source will utilize the ferroelectric ceramic BaTiO 3 to form metal plasma. A 1 m long section of the drift tube inner surface of NTX will be covered with ceramic. A high voltage (˜1-5 kV) is applied between the drift tube and the front surface of the ceramic by placing a wire grid on the front surface. Plasma densities of 10 12 cm -3 and neutral pressures ˜10 -6 Torr are expected. A test stand to produce 20 cm long plasma is being constructed and will be tested before a 1 m long source is developed.

  5. Staged lengthening arthroplasty for pediatric osteosarcoma around the knee.

    PubMed

    Kong, Chang-Bae; Lee, Soo-Yong; Jeon, Dae-Geun

    2010-06-01

    Orthopaedic oncologists often must address leg-length discrepancy after resection of tumors in growing patients with osteosarcoma. There are various alternatives to address this problem. We describe a three-stage procedure: (1) temporary arthrodesis, (2) lengthening by Ilizarov apparatus, and (3) tumor prosthesis. We asked (1) to what extent are affected limbs actually lengthened; (2) how many of the patients who undergo a lengthening procedure eventually achieve joint arthroplasty; and (3) can the three-stage procedure give patients a functioning joint with equalization of limb length? We reviewed 56 patients (younger than 14 years) with osteosarcoma who had staged lengthening arthroplasty between 1991 and 2004. Thirty-five of the 56 patients (63%) underwent soft tissue lengthening, and of these 35, 28 (50% of the original group of 56) had implantation of a mobile joint. Three of the 28 prostheses were later removed owing to infection after arthroplasty. The overall average length gained was 7.8 cm (range, 4-14 cm), and 25 (71%) of the 35 patients had a mobile joint at final followup. The average Musculoskeletal Tumor Society functional score was 23.2 (range, 15-28) and limb-length discrepancy at final followup was 2.6 cm (range, 0-6.5 cm). Although most mobile joints had an acceptable ROM (average, 74.2 degrees ; range, 35 degrees -110 degrees ), extension lag was frequent. Our approach is one option for skeletally immature patients, especially in situations where an expandable prosthesis is not available. However, this technique requires multiple stages and would be inappropriate for patients who cannot accept prolonged functional deficit owing to a limited lifespan or other reasons. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  6. [Treatment of juvenile scoliosis: Increasing the lengthening interval with the growing rod technique should not necessarily compromise thoracic growth].

    PubMed

    Pizones, J; Rodríguez-López, T; Zúñiga, L; Sánchez-Mariscal, F; Álvarez-González, P; Izquierdo, E

    2014-01-01

    Serial lengthening with growing rods is recommended every six months for the treatment of early onset scoliosis. The objective of this study was to evaluate the longitudinal growth of the thorax and control of the deformity in a series of patients with juvenile scoliosis when time intervals were increased between lengthenings. Retrospective study of eight patients. The following variables were measured: the Cobb angle, the apical vertebral translation, the coronal balance, thoracic T1-L1 length, thoracic T5-T12 kyphosis, the proximal junctional kyphosis (PJK) angle, and the lumbar lordosis. Complications were recorded. Five idiopathic and three syndromic scoliosis cases (mean age 9.4 ± 1.5 years) were evaluated. The initial surgery was followed by with an average of two distractions per patient. The mean time between distractions was 15.7 months. The final coronal main curve correction was 58%. Apical translation and coronal balance were improved and maintained after the surgeries. The thoracic (T1-L1) preoperative length was 20.8 cm, the postoperative length was 24.4 cm, and the final length was 26 cm. At the end of follow-up, the average growth of the thorax was 5.2 cm. The preoperative (T5-T12) kyphosis was 33.5°, and final 32.1°. The change in the PJK angle was 2.5° at the end of follow-up. Most complications were related to instrumentation. Two superficial wound infections were encountered. For less severe juvenile scoliosis patients treated with growing rods, spacing out lengthenings over more than a year can decrease the number of surgeries, while still controlling the deformity and allowing longitudinal thoracic growth. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  7. Emerging methanol-tolerant AlN nanowire oxygen reduction electrocatalyst for alkaline direct methanol fuel cell.

    PubMed

    Lei, M; Wang, J; Li, J R; Wang, Y G; Tang, H L; Wang, W J

    2014-08-11

    Replacing precious and nondurable Pt catalysts with cheap materials is a key issue for commercialization of fuel cells. In the case of oxygen reduction reaction (ORR) catalysts for direct methanol fuel cell (DMFC), the methanol tolerance is also an important concern. Here, we develop AlN nanowires with diameters of about 100-150 nm and the length up to 1 mm through crystal growth method. We find it is electrochemically stable in methanol-contained alkaline electrolyte. This novel material exhibits pronounced electrocatalytic activity with exchange current density of about 6.52 × 10(-8) A/cm(2). The single cell assembled with AlN nanowire cathodic electrode achieves a power density of 18.9 mW cm(-2). After being maintained at 100 mA cm(-2) for 48 h, the AlN nanowire-based single cell keeps 92.1% of the initial performance, which is in comparison with 54.5% for that assembled with Pt/C cathode. This discovery reveals a new type of metal nitride ORR catalyst that can be cheaply produced from crystal growth method.

  8. Benchtop Energetics: Research Progress, Concept Evaluation, and Apparatus Development

    DTIC Science & Technology

    2012-01-31

    have removed the relay imaging optics, and currently use a single 40 cm focal length lens, placed ≈ 48 cm from the target surface, to image the...24 1. Photographic Flyer Velocity Measurements ......................................... 24 2. Impact Luminescence Flyer...27 4. Time-Resolved Impact Luminescence Spectroscopy ........................... 28 E. Mass Spectrometric Diagnostics

  9. Wire-type MnO2/Multilayer graphene/Ni electrode for high-performance supercapacitors

    NASA Astrophysics Data System (ADS)

    Hu, Minglei; Liu, Yuhao; Zhang, Min; Wei, Helin; Gao, Yihua

    2016-12-01

    Commercially available wearable energy storage devices need a wire-type electrode with high strength, conductivity and electrochemical performance, as well as stable structure under deformation. Herein, we report a novel wire-type electrode of hierarchically structure MnO2 on Ni wire with multilayer graphene (MGr) as a buffer layer to enhance the electrical conductivity of the MnO2 and interface contact between the MnO2 and Ni wire. Thus, the wire-type MnO2/MGr/Ni electrode has a stable and high quality interface. The wire-type supercapacitor (WSC) based on wire-type MnO2/MGr/Ni electrode exhibits good electrochemical performance, high rate capability, extraordinary flexibility, and superior cycle lifetime. Length (area, volumetric) specific capacitance of the WSC reaches 6.9 mF cm-1 (73.2 mF cm-2, 9.8 F cm-3). Maximum length (volumetric) energy density of the WSC based on MnO2/MGr/Ni reaches 0.62 μWh cm-1 (0.88 mWh cm-3). Furthermore, the WSC has a short time constant (0.5-400 ms) and exhibits minimal change in capacitance under different bending shapes.

  10. Composition of Apollo 17 core 76001

    NASA Technical Reports Server (NTRS)

    Korotev, Randy L.; Bishop, Kaylynn M.

    1993-01-01

    Core 76001 is a single drive tube containing a column of regolith taken at the base of the North Massif, station 6, Apollo 17. The core material is believed to have accumulated through slow downslope mass wasting from the massif. As a consequence, the core soil is mature throughout its length. Results of INAA for samples taken every half centimeter along the length of the core indicate that there is only minor systematic compositional variation with depth. Concentrations of elements primarily associated with mare basalt (Sc, Fe) and noritic impact melt breccia (Sm) decrease slightly with depth, particularly between 20 cm and the bottom of the core at 32 cm depth. This is consistent with petrographic studies that indicate a greater proportion of basalt and melt breccia in the top part of the core. However, Sm/Sc and La/Sm ratios are remarkably constant with depth, indicating no variation in the ratio of mare material to Sm-rich highlands material with depth. Other than these subtle changes, there is no compositional evidence for the two stratigraphic units (0-20 cm and 20-32 cm) defined on the basis of modal petrography, although all samples with anomalously high Ni concentrations (Fe-Ni metal nuggets) occur above 20 cm depth.

  11. Ecology of juvenile hawksbills (Eretmochelys imbricata) at Buck Island Reef National Monument, US Virgin Islands

    USGS Publications Warehouse

    Hart, Kristen M.; Sartain-Iverson, Autumn R.; Hillis-Starr, Zandy; Phillips, Brendalee; Mayor, Philippe A.; Roberson, Kimberly; Pemberton, Roy A.; Allen, Jason B.; Lundgren, Ian; Musick, Susanna

    2013-01-01

    Surveys of juvenile hawksbills around Buck Island Reef National Monument, US Virgin Islands from 1994 to 1999 revealed distributional patterns and resulted in a total of 75 individual hawksbill captures from all years; turtles ranged from 23.2 to 77.7 cm curved carapace length (CCL; mean 42.1 ± 12.3 cm SD). Juveniles concentrated where Zoanthid cover was highest. Length of time between recaptures, or presumed minimum site residency, ranged from 59 to 1,396 days (mean 620.8 ± 402.4 days SD). Growth rates for 23 juveniles ranged from 0.0 to 9.5 cm year−1 (mean 4.1 ± 2.4 cm year−1SD). Annual mean growth rates were non-monotonic, with the largest mean growth rate occurring in the 30–39 cm CCL size class. Gastric lavages indicated that Zoanthids were the primary food source for hawksbills. These results contribute to our understanding of juvenile hawksbill ecology and serve as a baseline for future studies or inventories of hawksbills in the Caribbean.

  12. NASA-STD-6001B Test 1 Upward Flame Propagation; Sample Length Impact on MOC Investigation

    NASA Technical Reports Server (NTRS)

    Harper, Susana Tapia; Juarez, Alfredo; Woods, Brenton L.; Beeson, Harold D.

    2017-01-01

    Understanding the combustion behavior of materials in the elevated oxygen environments of habitable spacecraft is of utmost importance to crew safety and mission success. Currently, certification for unrestricted flight usage of a material with respect to flammability involves passing the Upward Flame Propagation Test of NASA-STD-6001B (Test 1). This test evaluates materials in a standardized test configuration for two failure criteria: self-extinguishment within 15 cm (6 in.) and the propensity of flame propagation by means of flaming material transfer. By the NASA standard, full-length samples are 30 cm (12 in.) in length; however, factors independent of the test method such as limited material availability or various nonstandard test configurations limit the full pretest sample lengths available for test. This paper characterizes the dependence, if any, of pretest sample length on NASA-STD-6001B Test 1 results. Testing was performed using the Maximum Oxygen Concentration (MOC) Threshold Method to obtain a data set for each sample length tested. In addition, various material types, including cloth (Nomex), foam (TA-301) and solids (Ultem), were tested to investigate potential effects of test specimen types. Though additional data needs to be generated to provide statistical confidence, preliminary findings are that use of variable sample lengths has minimal impact on NASA-STD-6001B flammability performance and MOC determination.

  13. Minnesota wolf ear lengths as possible indicators of taxonomic differences

    USGS Publications Warehouse

    Mech, L. David

    2011-01-01

    Genetic findings suggest that 2 types of wolves, Canis lupus (Gray Wolf) and C. lycaon (Eastern Wolf), and/or their hybrids occupy Minnesota (MN), and this study examines adult wolf ear lengths as a possible distinguisher between these two. Photographic evidence suggested that the Eastern Wolf possesses proportionately longer ears than Gray Wolves. Ear lengths from 22 northwestern MN wolves from the early 1970s and 22 Alaskan wolves were used to represent Gray Wolves, and the greatest length of the sample (12.8 cm) was used as the least length to demarcate Eastern Wolf from Gray Wolf influence in the samples. Twenty-three percent of 112 adult wolves from Algonquin Park in eastern Ontario and 30% of 106 recent adult wolves in northeastern MN possessed ears >12.8 cm. The northeastern MN sample differed significantly from that of current and past northwestern MN wolves. Ear-lengths of wolves in the eastern half of the northeastern MN wolf population were significantly longer than those in the western half of that study area, even though the mean distance between the 2 areas was only 40 km, and the mean length of my 2004–2009 sample was significantly longer than that of 1999–2003. These findings support the hypothesis that Eastern Wolves tend to possess longer ears than do Gray Wolves and suggest a dynamic hybridization process is still underway in MN.

  14. African hair length in a school population: a clue to disease pathogenesis?

    PubMed

    Khumalo, N P; Gumedze, F

    2007-09-01

    Anecdotal data suggest that combed natural African hair reaches a length steady state. Easier grooming and anticipated long hair have made relaxers popular. These hypotheses were tested in a cross-sectional survey of 1042 school children using a piloted questionnaire and hair length measurements done on four scalp regions. Participants included 45% boys and 55% girls. Girls consider length important for hairstyle choice (P < 0.0001). There was no difference in mean length at 2 to 5 vs. > 5 years (P = 0.3) and at 1 to < 2 vs. 2 to 5 years (P = 0.99), suggesting that a steady state is reached within 1 year after a hair cut for combed natural hair [mean, 5.1 cm (4.3)]. Relaxed hair reached length steady state > 2 years after a haircut [mean, 10.9 cm (3.6)], was longer than natural hair (P < 0.0001), shorter than expected, and significantly shorter on the occiput than the rest of the scalp (P < 0.0001). Persistently short combed natural hair years after a hair cut suggests that breakage eventually equals new growth (i.e., steady state), which is likely to be variable. Relaxed hair, irrespective of last haircut, is also short; chemical damage as a limit to potential lengths needs confirmation. Relatively short occipital relaxed hair could be a clue to disease pathogenesis.

  15. Analysis of the arterial anatomical variations of thyroid gland: anatomic guide for surgical neck dissection.

    PubMed

    Ray, B; Pugazhandhi, B; D'Souza, A S; Saran, S; Fasil, M; Srinivasa, R S

    2012-01-01

    Aim of this study was to establish preliminary data on the variations of arterial supply of thyroid gland in Karnataka population. The anterior triangles in the neck of formalin fixed cadavers were dissected. The length, branching pattern, number and length of branches of superior thyroid artery (STA) were noted. We measured the length of inferior thyroid artery (ITA) from its point of emergence from thyrocervical trunk (TCT) to lower pole of thyroid gland. The length of the external carotid artery (ECA), TCT from the point of its emergence to the point of its branching was noted. We noted the number of branches from ITA and TCT. Presence of any additional artery supplying the thyroid gland was searched for. Difference in the length of STA and ITA between the two sexes and sides were noted. Statistical analysis was done by Student's t-test. In our study the maximum length of STA was 5.34cm and that of ITA was 5.07cm and there were no statistically significant side-to-side differences in level of bifurcation. Observations of the present study on the course and branching pattern of arteries around thyroid gland will help in easier approach during thyroid surgeries and interventional techniques (Tab. 1, Fig. 3, Ref. 38).

  16. A proposed STAR microvertex detector using Active Pixel Sensors with some relevant studies on APS performance

    NASA Astrophysics Data System (ADS)

    Kleinfelder, S.; Li, S.; Bieser, F.; Gareus, R.; Greiner, L.; King, J.; Levesque, J.; Matis, H. S.; Oldenburg, M.; Ritter, H. G.; Retiere, F.; Rose, A.; Schweda, K.; Shabetai, A.; Sichtermann, E.; Thomas, J. H.; Wieman, H. H.; Bichsel, H.

    2006-09-01

    A vertex detector that can measure particles with charm or bottom quarks would dramatically expand the physics capability of the STAR detector at RHIC. To accomplish this, we are proposing to build the Heavy Flavor Tracker (HFT) using 2×2 cm Active Pixels Sensors (APS). Ten of these APS chips will be arranged on a ladder (0.28% of a radiation length) at radii of 1.5 and at 5.0 cm. We have examined several properties of APS chips, so that we can characterize the performance of this detector. Using 1.5 GeV/ c electrons, we have measured the charge collected and compared it to the expected charge. To achieve high efficiency, we have considered two different cluster finding algorithms and found that the choice of algorithm is dependent on noise level. We have demonstrated that a Scanning Electron Microscope can probe properties of an APS chip. In particular, we studied several position resolution algorithms. Finally, we studied the properties of pixel pitches from 5 to 30 μm.

  17. Relationship between the surrogate anthropometric measures, foot length and chest circumference and birth weight among newborns of Sarlahi, Nepal.

    PubMed

    Mullany, L C; Darmstadt, G L; Khatry, S K; Leclerq, S C; Tielsch, J M

    2007-01-01

    Classification of infants into low birth weight (LBW, <2500 g) or very low birth weight (VLBW, <2000 g) categories is a crucial step in targeting interventions to high-risk infants. To compare the validity of chest circumference and foot length as surrogate anthropometric measures for the identification of LBW and VLBW infants. Newborn infants (n=1640) born between March and June 2004 in 30 Village Development Committees of Sarlahi district, Nepal. Chest circumference, foot length and weight (SECA 727, precise to 2 g) of newborns were measured within 72 h after birth. The sensitivity, specificity and predictive values for a range of cutoff points of the anthropometric measures were estimated using the digital scale measurements as the gold standard. Among LBW infants (469/1640, 28.6%), chest circumference measures <30.3 cm were 91% sensitive and 83% specific. Similar levels of sensitivity for foot length were achieved only with considerable loss of specificity (<45%). Foot length measurements <6.9 cm were 88% sensitive and 86% specific for the identification of VLBW infants. Chest circumference was superior to foot length in classification of infants into birth weight categories. For the identification of VLBW infants, foot length performed well, and may be preferable to chest circumference, as the former measure does not require removal of infant swaddling clothes. In the absence of more precise direct measures of birth weight, chest circumference is recommended over foot length for the identification of LBW infants.

  18. ELECTRICAL AEROSOL DETECTOR (EAD) MEASUREMENTS AT THE ST. LOUIS SUPERSITE

    EPA Science Inventory

    The Model 3070A Electrical Aerosol Detector (EAD) measures a unique aerosol parameter called total aerosol length. Reported as mm/cm3, aerosol length can be thought of as a number concentration times average diameter, or simply as d1 weighting. This measurement falls between nu...

  19. Trough Coating Solar Cells Without Spillover

    NASA Technical Reports Server (NTRS)

    Heaps, J. D.

    1986-01-01

    Problem with trough coating of silicon on ceramic - spillover of molten silicon - overcome by combination of redesigned heaters and tiltable trough. Modifications make it possible to coat virtually any length of ceramic with film of solar-cell-grade silicon. Previously, maximum length coated before spillover occurred was 2 inches (5.1 cm).

  20. EFFECT OF SIZE OF INTESTINAL DIVERSIONS IN OBESE PATIENTS WITH METABOLIC SYNDROME SUBMITTED TO GASTRIC BYPASS.

    PubMed

    Ramos, Rafael Jacques; Mottin, Cláudio Corá; Alves, Letícia Biscaino; Benzano, Daniela; Padoin, Alexandre Vontobel

    There is no consensus on the ideal size of intestinal loops in gastric bypass of bariatric surgeries. To evaluate the metabolic outcome of patients submitted to gastric bypass with alimentary and biliopancreatic loops of different sizes. Was conducted a retrospective cohort study in diabetic obese patients (BMI≥35 kg/m2) with metabolic syndrome submitted to gastric bypass. The patients were divided into three groups according to the size of the intestinal loop: group 1, biliopancreatic limb 50 cm length and alimentary limb 100 cm length; group 2 , biliopancreatic limb 50 cm length and alimentary limb 150 cm length; and group 3, biliopancreatic limb 100 cm length and alimentary limb 150 cm length. The effect of gastric bypass with different sizes of intestinal loops in relation to the parameters that define metabolic syndrome was determined. Sixty-three patients were evaluated, and they had a mean age of 44.7±9.4 years. All were diabetics, with 62 (98.4%) being hypertensive and 51 (82.2%) dyslipidemic. The three groups were homogeneous in relation to the variables. In 24 months, there was a remission of systemic arterial hypertension in 65% of patients in group 1, 62.5% in group 2 and 68.4% in group 3. Remission of diabetes occurred in 85% of patients in group 1, 83% in group 2 and 84% in group 3. There was no statistical difference in %LEW between the groups, and waist measurements decreased in a homogeneous way in all groups. The size of loops also had no influence on the improvement in dyslipidemia. Variation in size of intestinal loops does not appear to influence improvement in metabolic syndrome in this group of patients. Não há consenso sobre o tamanho ideal das alças intestinais no bypass gástrico em Y-de-Roux em cirurgias bariátricas. Avaliar os desfechos metabólicos de pacientes submetidos ao bypass gástrico com alça intestinal alimentar e biliopancreática de tamanhos diferentes. Realizou-se coorte retrospectiva em pacientes obesos (IMC≥35 kg/m2) diabéticos com síndrome metabólica submetidos ao bypass gástrico em Y-de-Roux. Foram divididos em três grupos conforme a dimensão das alças intestinais: grupo 1, alça biliopancreática de 50 cm e alça alimentar de 100 cm; grupo 2, alça biliopancreática de 50 cm e alça alimentar de 150 cm e grupo 3, alça biliopancreática de 100 cm e alça alimentar de 150 cm. Foram avaliados os parâmetros que compõem a síndrome metabólica. Incluíram-se 63 pacientes, com média de idade de 44.7±9.4 anos. Todos eram diabéticos, 62 (98.4%) hipertensos e 51 (82.2%) dislipidêmicos. Os três grupos eram homogêneos em relação às variáveis estudadas. Em 24 meses houve remissão da hipertensão arterial sistêmica em 65% do grupo 1, 62.5% no grupo 2 e 68.4% no grupo 3. A remissão do diabete melito tipo 2 ocorreu em 85% dos pacientes do grupo 1, 83% no grupo 2, e 84% no grupo 3. Não houve diferença estatística na porcentagem de perda do excesso de peso entre os grupos e as medidas da cintura abdominal reduziram de forma homogênea em todos os grupos. A dimensão das alças também não influenciou na melhora da dislipidemia. A variação da dimensão das alças intestinais não influenciou na melhora da síndrome metabólica neste grupo de pacientes.

  1. Measurements and FLUKA Simulations of Bismuth, Aluminium and Indium Activation at the upgraded CERN Shielding Benchmark Facility (CSBF)

    NASA Astrophysics Data System (ADS)

    Iliopoulou, E.; Bamidis, P.; Brugger, M.; Froeschl, R.; Infantino, A.; Kajimoto, T.; Nakao, N.; Roesler, S.; Sanami, T.; Siountas, A.; Yashima, H.

    2018-06-01

    The CERN High energy AcceleRator Mixed field (CHARM) facility is situated in the CERN Proton Synchrotron (PS) East Experimental Area. The facility receives a pulsed proton beam from the CERN PS with a beam momentum of 24 GeV/c with 5·1011 protons per pulse with a pulse length of 350 ms and with a maximum average beam intensity of 6.7·1010 protons per second. The extracted proton beam impacts on a cylindrical copper target. The shielding of the CHARM facility includes the CERN Shielding Benchmark Facility (CSBF) situated laterally above the target that allows deep shielding penetration benchmark studies of various shielding materials. This facility has been significantly upgraded during the extended technical stop at the beginning of 2016. It consists now of 40 cm of cast iron shielding, a 200 cm long removable sample holder concrete block with 3 inserts for activation samples, a material test location that is used for the measurement of the attenuation length for different shielding materials as well as for sample activation at different thicknesses of the shielding materials. Activation samples of bismuth, aluminium and indium were placed in the CSBF in September 2016 to characterize the upgraded version of the CSBF. Monte Carlo simulations with the FLUKA code have been performed to estimate the specific production yields of bismuth isotopes (206 Bi, 205 Bi, 204 Bi, 203 Bi, 202 Bi, 201 Bi) from 209 Bi, 24 Na from 27 Al and 115 m I from 115 I for these samples. The production yields estimated by FLUKA Monte Carlo simulations are compared to the production yields obtained from γ-spectroscopy measurements of the samples taking the beam intensity profile into account. The agreement between FLUKA predictions and γ-spectroscopy measurements for the production yields is at a level of a factor of 2.

  2. [Growth assessment of children with neonatal short bowel syndrome (SBS)].

    PubMed

    Dalieri, M; Fabeiro, M; Prozzi, M; Barcellandi, P; Martínez, M; Galarraga, M; Fernández, A

    2007-01-01

    SBS is a complex entity with high morbimortality. Survival following extent intestinal resection during the neonatal period is higher than 90%. Nutritional support is paramount during the periods of high growth. To assess growth of children with neonatal SBS neonatal having received during the first two years of life. A retrospective study was done on patients assisted at the Nutrition Department of the Children's Hospital of La Plata. The following parameters were gathered: gestational age (GA), diagnosis, length of the remnant bowel, liver impairment, duration of PN and EN, and socio-economical profile of the patients. Growth assessment was done by: weight (W), height (H) at two years (Control I), and at the last follow-up visit done at the Department (Control II), using the NCHS tables. Weight and height were expressed as the Z score (Z) and the percentage of W/H, and were related to need of long-term NS. Patients were categorized into three groups according to NS requirement at the time of Control II: PN-dependent, EN-dependent, and those not requiring nutritional support (WOS). Eighteen patients were included. Length of the remnant bowel was: 45 cm. (r 10-80 cm.), length was < 40 cm in 11 pts. (61%) (massive resection). The ileocecal valve was resected in 9 pts. (50%) and 3 pts. (16 %) required partial colon resection and 2 pts. (11%) total resection. Mean Z scores for W/A, H/A, %W/H, Z W/H yielded values < -2 SD, and the percentage of W/H appropriateness was > 90% in both controls. Twenty seven percent of the patients at two years of age, and 33% at the last control showed height < -2 SD. Two patients (11%) died while on PN from liver failure, both with 10 cm of remnant bowel and without VIC. At Control II, 4 patients (22%) remained PN-dependent. Mean length of the remnant bowel in this group was 33 cm (r: 17-50) and mean follow-up duration with PN was 2176 days (r: 750-4380). Six patients (33%) remained EN-dependent at Control II, with a mean intestinal length of 41 cm (r: 20-75) and 2 out of 6 pts. did not have VIC. This group of patients required PN as the initial therapy with a mean duration of 629 days. Follow-up time while on EN was 627 days (r: 210-3010). Six patients (33%) achieved nutritional support independence (WOS) with a mean intestinal length of 60 cm (r: 27-80) after a mean duration of NS of 791 days, being assisted with dietary recommendations and vitamins and minerals supplementation. The group showing the greatest growth impairment was the EN-dependent group since we consider that early withdrawal of PN was decided based on inappropriate socio-environmental conditions. According to the present study, we conclude that is may be possible to achieve a normal growth in children with neonatal SBS under nutritional support and that complications related to this nutritional therapy or difficulties for adequately implementing it at home may affect the final height.

  3. Theoretical study on the potential energy surfaces of CaNC and CaCN

    NASA Astrophysics Data System (ADS)

    Ishii, Keisaku; Taketsugu, Tetsuya; Hirano, Tsuneo

    2003-06-01

    The potential energy surfaces of CaNC ( overlineX2Σ+) and CaCN ( overlineX2Σ+) have been investigated by the highly correlated ab initio molecular orbital methods. The bending potential for CaNC is shallow, and shows quite anharmonic and anomalous character, which can explain why the centrifugal distortion constants up to the tenth order were required for the analysis of its rotational spectrum. The reaction path for the isomerization reaction of CaNC and CaCN was also determined: The activation barrier is 2111 cm -1 from the CaNC side, and 602 cm -1 from the CaCN side. Core-core and core-valence correlation contributions of Ca M-shell electrons make the Ca-N (for CaNC) and Ca-C (for CaCN) bond lengths shorter by 0.05 and 0.04 Å, respectively, which indicates the significance of these core-correlation effects.

  4. Visualization of light propagation in visible Chinese human head for functional near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Li, Ting; Gong, Hui; Luo, Qingming

    2011-04-01

    Using the visible Chinese human data set, which faithfully represents human anatomy, we visualize the light propagation in the head in detail based on Monte Carlo simulation. The simulation is verified to agree with published experimental results in terms of a differential path-length factor. The spatial sensitivity profile turns out to seem like a fat tropical fish with strong distortion along the folding cerebral surface. The sensitive brain region covers the gray matter and extends to the superficial white matter, leading to a large penetration depth (>3 cm). Finally, the optimal source-detector separation is suggested to be narrowed down to 3-3.5 cm, while the sensitivity of the detected signal to brain activation reaches the peak of 8%. These results indicate that the cerebral cortex folding geometry actually has substantial effects on light propagation, which should be necessarily considered for applications of functional near-infrared spectroscopy.

  5. Experimental Observation of Near-Field Deterioration Induced by Stimulated Rotational Raman Scattering in Long Air Paths

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Zhang, Xiao-Min; Han, Wei; Li, Fu-Quan; Zhou, Li-Dan; Feng, Bin; Xiang, Yong

    2011-08-01

    We report the experimental investigation of a stimulated rotational Raman scattering effect in long air paths on SG-III TIL, with a 1053 nm, 20-cm-diameter, linearly polarized, 3 ns flat-topped laser pulse. An intense speckle pattern of near field with thickly dotted hot spots is observed at the end of propagation with an intensity-length product above 17TW/cm. The Stokes developing from the scattering of the laser beam by quantum fluctuations is characterized by a combination of high spatial frequency components. The observed speckle pattern with small-diameter hot spots results from the combination of the nonlinear Raman amplification and the linear diffraction propagation effect of the Stokes with a noise pattern arising from the spontaneous Raman scattering. A new promising suppression concept based on the special characteristic of the Stokes, called active and selective filtering of Stokes, is proposed.

  6. A Planar Source of Atmospheric-Pressure Plasma Jet

    NASA Astrophysics Data System (ADS)

    Zhdanova, O. S.; Kuznetsov, V. S.; Panarin, V. A.; Skakun, V. S.; Sosnin, E. A.; Tarasenko, V. F.

    2018-01-01

    In a single-barrier discharge with voltage sharpening and low gas consumption (up to 1 L/min), plane atmospheric pressure plasma jets with a width of up to 3 cm and length of up to 4 cm in air are formed in the slit geometry of the discharge zone. The energy, temperature, and spectral characteristics of the obtained jets have been measured. The radiation spectrum contains intense maxima corresponding to vibrational transitions of the second positive system of molecular nitrogen N2 ( C 3Π u → B 3Π g ) and comparatively weak transition lines of the first positive system of the N 2 + ion ( B 2Σ u + → X 2Σ g ). By an example of inactivation of the Staphylococcus aureus culture (strain ATCC 209), it is shown that plasma is a source of chemically active particles providing the inactivation of microorganisms.

  7. The optimal thickness of a transmission-mode GaN photocathode

    NASA Astrophysics Data System (ADS)

    Wang, Xiao-Hui; Shi, Feng; Guo, Hui; Hu, Cang-Lu; Cheng, Hong-Chang; Chang, Ben-Kang; Ren, Ling; Du, Yu-Jie; Zhang, Jun-Ju

    2012-08-01

    A 150-nm-thick GaN photocathode with a Mg doping concentration of 1.6 × 1017 cm-3 is activated by Cs/O in an ultrahigh vacuum chamber, and a quantum efficiency (QE) curve of the negative electron affinity transmission-mode (t-mode) of the GaN photocathode is obtained. The maximum QE reaches 13.0% at 290 nm. According to the t-mode QE equation solved from the diffusion equation, the QE curve is fitted. From the fitting results, the electron escape probability is 0.32, the back-interface recombination velocity is 5 × 104 cm·s-1, and the electron diffusion length is 116 nm. Based on these parameters, the influence of GaN thickness on t-mode QE is simulated. The simulation shows that the optimal thickness of GaN is 90 nm, which is better than the 150-nm GaN.

  8. Experimental and numerical investigations of effect of column length on retardation factor determination: a case study of cesium transport in crushed granite.

    PubMed

    Li, Ming-Hsu; Wang, Tsing-Hai; Teng, Shi-Ping

    2009-02-15

    This study investigated breakthrough curves (BTCs) from a series of column experiments, including different column lengths and flow rates, of a conservative tracer, tritium oxide (HTO), and a radionuclide, cesium, in crushed granite using a reactive transport model. Results of the short column, with length of 2cm, showed an underestimation of the retardation factor and the corresponding HTO BTCs cannot be successfully modeled even with overestimated fluid dispersivity. Column supporting elements, including filters and rings, on both ends of packed granite were shown to be able to induce additional dispersive mixing, thus significantly affecting BTCs of short columns while those of the long column, with length of 8cm, were less affected. By increasing flow rates from 1mL/min to 5mL/min, the contribution of structural dispersive mixing to the false tilting of short column BTCs still cannot be detached. To reduce the influence of structural dispersivity on BTCs, the equivalent pore volume of column supporting materials should be much smaller than that of packed porous medium. The total length of column supporting structures should be greatly shorter than that of porous medium column.

  9. To what extent is coherence lost in tissue?

    NASA Astrophysics Data System (ADS)

    Hode, Tomas; Jenkins, Peter; Jordison, Stefan; Hode, Lars

    2011-03-01

    In a series of experiments we investigated the extent to which coherence is preserved in tissue. We investigated whether the decrease in coherence length is dependent upon the coherence length of the illuminating light and possibly also if the light is polarized. We compared highly coherent light from a HeNe laser, and less coherent light from a semiconductor laser, in scattering media such as raw ground beef. We studied the laser speckle contrast after passing through 1 - 2 cm of meat. The conclusion is that the laser light is still coherent enough to form laser speckles after passing through a 2 cm thickness of meat.

  10. Cavity ring-down spectroscopy in the liquid phase

    NASA Astrophysics Data System (ADS)

    Xu, Shucheng; Sha, Guohe; Xie, Jinchun

    2002-02-01

    A new application for cavity ring-down spectroscopic (CRDS) technique using a pulsed polarized light source has been developed in the absorption measurement of liquids for "colorless" organic compounds using both a single sample cell and double sample cells inserted in an optical cavity at Brewster angle. At present an experimental capability of measuring absorption coefficients as small as 2-5×10-7 cm-1 has been demonstrated by measurement of the absorption baselines. The first spectra for CRDS in the liquid phase, the C-H stretching fifth vibrational overtones of benzene in the pure liquid and hexane solution are obtained. The optical absorption length for liquids in both a single sample cell and double sample cells of 1 cm length is up to 900 cm due to multipass of light within an optical cavity. Compared to the thermal lens and optoacoustic spectroscopic techniques, the sensitivity for CRDS mainly depends on the optical absorption path of the sample (single passing path of the sample times multipass times), is not determined by the laser power and the length of the sample cell. The absolute absorption coefficient and band intensity for the sample are determined directly by the spectroscopy.

  11. Relative dosimetrical verification in high dose rate brachytherapy using two-dimensional detector array IMatriXX

    PubMed Central

    Manikandan, A.; Biplab, Sarkar; David, Perianayagam A.; Holla, R.; Vivek, T. R.; Sujatha, N.

    2011-01-01

    For high dose rate (HDR) brachytherapy, independent treatment verification is needed to ensure that the treatment is performed as per prescription. This study demonstrates dosimetric quality assurance of the HDR brachytherapy using a commercially available two-dimensional ion chamber array called IMatriXX, which has a detector separation of 0.7619 cm. The reference isodose length, step size, and source dwell positional accuracy were verified. A total of 24 dwell positions, which were verified for positional accuracy gave a total error (systematic and random) of –0.45 mm, with a standard deviation of 1.01 mm and maximum error of 1.8 mm. Using a step size of 5 mm, reference isodose length (the length of 100% isodose line) was verified for single and multiple catheters of same and different source loadings. An error ≤1 mm was measured in 57% of tests analyzed. Step size verification for 2, 3, 4, and 5 cm was performed and 70% of the step size errors were below 1 mm, with maximum of 1.2 mm. The step size ≤1 cm could not be verified by the IMatriXX as it could not resolve the peaks in dose profile. PMID:21897562

  12. Genetic Parameters And Selection Response For Yield Traits In Bread Wheat Under Irrigated And Rainfed Environments

    NASA Astrophysics Data System (ADS)

    Khalil, Iftikhar Hussain; at-ur-Rahman, Hiday; Khan, Imran

    2008-01-01

    A set of 22 F5:7 experimental wheat lines along with four check cultivars (Dera-98, Fakhr-e-Sarhad, Ghaznavi-98 and Tatara) were evaluated as independent experiments under irrigated and rainfed environments using a randomized complete block design at NWFP Agricultural University, Peshawar during 2004-05. The two environments were statistically different for days to heading and spike length only. Highly significant genetic variability existed among the wheat lines (P<0.01) in the combined analysis across environments for all traits. Genotype×environment interactions were non-significant for all traits except 1000-grain weight indicating consistent performance of wheat genotypes across the two environments. Wheat lines and check cultivars were 2 to 5 days early in heading under rainfed environment compared to the irrigated. Plant height, spike length, 1000-grain weight, biological and grain yields were generally reduced under rainfed environment. Genetic variances were of greater magnitude than environmental variances for most of the traits in both environments. The heritability estimates were of higher magnitude (0.74 to 0.96) for days to heading, plant height, spike length, biological and grain yield, while medium (0.31 to 0.51) for 1000-grain weight. Selection differentials were negative for heading (-7.3 days in irrigated vs -9.4 days in rainfed) and plant height (-9.0 cm in irrigated vs -8.7 cm in rainfed) indicating possibility of selecting wheat genotypes with early heading and short plant stature. Positive selection differentials of 1.3 vs 1.6 cm for spike length, 3.8 vs 3.4 g for 1000-grain weight, 2488.2 vs 3139.7 kg ha-1 for biological yield and 691.6 vs 565.4 kg ha-1 for grain yield at 20% selection intensity were observed under irrigated and rainfed environments, respectively. Expected selection responses were 7.98 vs 8.91 days for heading, 8.20 vs 9.52 cm for plant height, 1.01 vs 1.61 cm for spike length, 2.12 vs 1.15 g for 1000-grain weight, 1655.8 vs 2317.2 kg ha-1 for biological yield and 691.6 vs 565.4 kg ha-1 for grain yield under the two test environments, respectively. The differential heritability and selection responses for yield and related traits suggest the simultaneous evaluation and selection of wheat lines under the two environments.

  13. Recombination properties of dislocations in GaN

    NASA Astrophysics Data System (ADS)

    Yakimov, Eugene B.; Polyakov, Alexander Y.; Lee, In-Hwan; Pearton, Stephen J.

    2018-04-01

    The recombination activity of threading dislocations in n-GaN with different dislocation densities and different doping levels was studied using electron beam induced current (EBIC). The recombination velocity on a dislocation, also known as the dislocation recombination strength, was calculated. The results suggest that dislocations in n-GaN giving contrast in EBIC are charged and surrounded by a space charge region, as evidenced by the observed dependence of dislocation recombination strength on dopant concentration. For moderate (below ˜108 cm-2) dislocation densities, these defects do not primarily determine the average diffusion length of nonequilibrium charge carriers, although locally, dislocations are efficient recombination sites. In general, it is observed that the effect of the growth method [standard metalorganic chemical vapor deposition (MOCVD), epitaxial lateral overgrowth versions of MOCVD, and hydride vapor phase epitaxy] on the recombination activity of dislocations is not very pronounced, although the average diffusion lengths can widely differ for various samples. The glide of basal plane dislocations at room temperature promoted by low energy electron irradiation does not significantly change the recombination properties of dislocations.

  14. Energy harvesting device based on a metallic glass/PVDF magnetoelectric laminated composite

    NASA Astrophysics Data System (ADS)

    Lasheras, A.; Gutiérrez, J.; Reis, S.; Sousa, D.; Silva, M.; Martins, P.; Lanceros-Mendez, S.; Barandiarán, J. M.; Shishkin, D. A.; Potapov, A. P.

    2015-06-01

    A flexible, low-cost energy-harvesting device based on the magnetoelectric (ME) effect was designed using Fe64Co17Si7B12 as amorphous magnetostrictive ribbons and polyvinylidene fluoride (PVDF) as the piezoelectric element. A 3 cm-long sandwich-type laminated composite was fabricated by gluing the ribbons to the PVDF with an epoxy resin. A voltage multiplier circuit was designed to produce enough voltage to charge a battery. The power output and power density obtained were 6.4 μW and 1.5 mW cm-3, respectively, at optimum load resistance and measured at the magnetomechanical resonance of the laminate. The effect of the length of the ME laminate on power output was also studied: the power output exhibited decays proportionally with the length of the ME laminate. Nevertheless, good performance was obtained for a 0.5 cm-long device working at 337 KHz within the low radio frequency (LRF) range.

  15. Growth charts for Australian children with achondroplasia.

    PubMed

    Tofts, Louise; Das, Sandeep; Collins, Felicity; Burton, Karen L O

    2017-08-01

    Achondroplasia is an autosomal dominant disorder, the most common genetic cause of short stature in humans. Reference curves for head circumference, weight, height, and BMI are needed in clinical practice but none exist for the Australian population. This study aimed to produce head circumference, height, weight, and BMI reference percentile curves for Australian children and adolescents with achondroplasia. Measurements of head circumference, height and weight taken at clinical visits were retrospectively extracted from the electronic medical record. Age was corrected for prematurity. Patients were excluded from head circumference analysis if they had significant neurosurgical complications and from the weight and BMI analysis when they had a clinical diagnosis of overweight. Measurements were available on 138 individuals (69 males and 69 females) taken between 1970 and 2015, with over 50% collected since 2005. A total of 3,352 data points were available. The LMS method was used to produce growth charts with estimated centiles (10, 25, 50, 75, and 90th) separately for males and females. For females birth weight was 3 kg (2.5-3.5 kg), birth length 48 cm (44-50 cm) and head circumference 37.5 cm (36-39 cm), adult height was 125 cm (116-132 cm), weight 42 kg (34-54 kg), and head circumference 58 cm (55.5-60.5 cm) all 50th centile (10-90th). For males birth weight was 3.5 kg (3-4 kg), length 49 cm (46-52 cm) and head circumference 38.5 cm (36-41 cm), adult height was 134 cm (125-141 cm), weight 41 kg (24.5-57 kg) and head circumference 61 cm (58-64 cm). The curves are similar to previously published reference data from the USA and have expected population wide variation from curves from an Argentinian population. Despite limitations of our curves for adolescents (12 years and older) due to data paucity, these Australian growth charts for children and adolescents with achondroplasia will be a useful reference in clinical practice. © 2017 Wiley Periodicals, Inc.

  16. Effect of leg length inequality on body weight distribution during walking with load: A pilot study

    NASA Astrophysics Data System (ADS)

    Zabri, S. W. K. Ali; Basaruddin, K. S.; Salleh, A. F.; Rusli, W. M. R.; Daud, R.

    2017-09-01

    This paper presents a pilot study on the effect of leg length inequality (LLI) on the body weight distribution. Plywood block was used to mimic the artificial LLI. The height of the plywood was increased up to 4.0 cm with 0.5 cm increment. Hence, eight different height of LLI was considered in order to investigate which height of LLI initiated the significant effect. The experiment was conducted on a healthy subject that walking on the force plate in two conditions; with a load of 2 kg (carried by a backpack worn by the subject) and without load. Qualisys Track Manager (QTM) system was employed for data processing. The results showed that the short leg subjected to more weight compared to the long leg during walking with inequality of leg length especially when carrying additional load.

  17. Broad bandwidth and 600 μm length photonic crystal fiber polarization filter at the communication window of 1.55 μm

    NASA Astrophysics Data System (ADS)

    Zhang, Zhen; Li, Shuguang; Liu, Qiang; Zhang, Shuhuan; Wang, Yujun; Wu, Junjun

    2018-02-01

    A broad bandwidth and 600-μm length photonic crystal fiber polarization filter at the communication window of 1.55 μm is proposed. The physical parameters are analyzed by the finite element method. In the structure, the loss is 705.81 dB/cm for y-polarized mode and 24.06 dB/cm for x-polarized mode at the wavelength of 1.55 μm; the y-polarized mode will be filtered out because of this property. The bandwidth of an extinction ratio (ER) better than -20 dB is 65 nm when the filter length is 600 μm, and the ER is -41 dB at the communication wavelength of 1.55 μm. The filter structure is simple and easy to produce, and it can be used to produce a single-polarization filter.

  18. Efficacy of passive capillary samplers for estimating soil water drainage in the vadose zone

    USDA-ARS?s Scientific Manuscript database

    The efficacy and accuracy of PCAP samplers were evaluated for continuous estimating of soil water drainage and fluxes below the rootzone of a sugarbeet-potato-barley rotation under two irrigation frequencies. Twelve automated PCAPs with outside sampling surface dimensions of 91 cm length x 31 cm wid...

  19. Heteroptera attracted to butterfly traps baited with fish or shrimp carrion

    USDA-ARS?s Scientific Manuscript database

    Records of Heteroptera collected at butterfly traps baited with fish or shrimp carrion during collecting trips to Bolivia, Brazil, Colombia, Ecuador, and Peru are presented. Traps consisted of a cylinder of net fabric (about 35 cm diam, 75 cm length) attached on the top and bottom to square pieces ...

  20. Undulatory Swimming Performance and Body Stiffness Modulation in a Soft Robotic Fish-Inspired Physical Model.

    PubMed

    Jusufi, Ardian; Vogt, Daniel M; Wood, Robert J; Lauder, George V

    2017-09-01

    Undulatory motion of the body is the dominant mode of locomotion in fishes, and numerous studies of body kinematics and muscle activity patterns have provided insights into the mechanics of swimming. However, it has not been possible to investigate how key parameters such as the extent of bilateral muscle activation affect propulsive performance due to the inability to manipulate muscle activation in live, freely swimming fishes. In this article we extend previous work on passive flexible mechanical models of undulatory propulsion by using actively controlled pneumatic actuators attached to a flexible foil to gain insight into undulatory locomotion and mechanisms for body stiffness control. Two soft actuators were attached on each side of a flexible panel with stiffness comparable to that of a fish body. To study how bilateral contraction can be used to modify axial body stiffness during swimming, we ran a parameter sweep of actuator contraction phasing and frequency. Thrust production by the soft pneumatic actuators was tested at cyclic undulation frequencies ranging from 0.3 to 1.2 Hz in a recirculating flow tank at flow speeds up to 28 cm/s. Overall, this system generated more thrust at higher tail beat frequencies, with a plateau in thrust above 0.8 Hz. Self-propelled speed was found to be 0.8 foil lengths per second or ∼13 cm/s when actuated at 0.55 Hz. This active pneumatic model is capable of producing substantial trailing edge amplitudes with a maximum excursion equivalent to 1.4 foil lengths, and of generating considerable thrust. Altering the extent of bilateral co-contraction in a range from -22% to 17% of the cycle period showed that thrust was maximized with some amount of simultaneous left-right actuation of ∼3% to 6% of the cycle period. When the system is exposed to water flow, thrust was substantially reduced for conditions of greatest antagonistic overlap in left-right actuation, and also for the largest latencies introduced. This experimental platform provides a soft robotic testbed for studying aquatic propulsion with active control of undulatory kinematics.

  1. Self Induced Buoyant Blow Off in Upward Flame Spread on Thin Solid Fuels

    NASA Technical Reports Server (NTRS)

    Johnston, Michael C.; T'ien, James S.; Muff, Derek E.; Olson, Sandra L.; Ferkul, Paul V.

    2013-01-01

    Upward flame spread experiments were conducted on a thin fabric cloth consisting of 75% cotton and 25% fiberglass. The sample is sandwiched symmetrically with stainless steel plates with the exposed width varying between 2 to 8.8 cm from test to test and >1.5m tall. The bottom edge was ignited resulting in a symmetric two sided flame. For the narrower samples (. 5cm), two sided flame growth would proceed until reaching some limiting value (15-30 cm depending on sample width). Fluctuation or instability of the flame base on one side would initially become visible and then the flame base would retreat downstream and cause extinguishment on one side. Detailed examination of the still images shows that the fuel continues to vaporize from the extinguished side due to the thermally thin nature of the fuel. But, due to the remaining inert fiberglass mesh, which acts as a flashback arrestor, the extinguished side was not able to be reignited by the remaining flame. The remaining flame would then shrink in length due to the reduced heat transfer to the solid to a shorter length. The one-sided flame will spread stably with a constant speed and a constant flame length to the end of the sample. A constant length flame implies that the pyrolysis front and the burnt out fronts move at the same speed. For the wider samples (. 7cm), no one-sided extinction is observed. Two-sided flames spread all the way to the top of the sample. For these wider widths, the flames are still growing and have not reached their limiting length if it exists. Care was taken to minimize the amount of non-symmetries in the experimental configuration. Repeated tests show that blow-off can occur on either side of the sample. The flame growth is observed to be very symmetric during the growth phase and grew to significant length (>10cm) before extinction of the flame on one side. Our proposed explanation of this unusual phenomenon (i.e. stronger two ]sided flame cannot exist but weaker one-sided flame can) is as follows: The observed one-sided extinction is a blow- off induced by buoyant entrainment. It is known that the flammable diffusion flame regime is bounded by quenching and blow ]off limits when varying incoming air velocity. The narrowest samples tested (between 2 and 5 cm) begin within the flammable range, but as the flame grows, the buoyancy driven air velocity increases at the neighborhood of the flame base. The initially stable flame crosses the extinguishment boundary resulting in a flame blow-off. When one-side of the flame extinguishes, the remaining side shrinks due to the reduced heat transfer to the solid. This reduces the induced velocity and the flame becomes stable. It is proposed that this may have implications to upward flame growth beyond this experiment.

  2. Improved performance of the microbial electrolysis desalination and chemical-production cell with enlarged anode and high applied voltages.

    PubMed

    Ye, Bo; Luo, Haiping; Lu, Yaobin; Liu, Guangli; Zhang, Renduo; Li, Xiao

    2017-11-01

    The aim of this study was to improve performance of the microbial electrolysis desalination and chemical-production cell (MEDCC) using enlarged anode and high applied voltages. MEDCCs with anode lengths of 9 and 48cm (i.e., the 9cm-anode MEDCC and 48cm-anode MEDCC, respectively) were tested under different voltages (1.2-3.0V). Our results demonstrated for the first time that the MEDCC could maintain high performance even under the applied voltage higher than that for water dissociation (i.e., 1.8V). Under the applied voltage of 2.5V, the maximum current density in the 48cm-anode MEDCC reached 32.8±2.6A/m 2 , which is one of the highest current densities reported so far in the bioelectrochemical system (BES). The relative abundance of Geobacter was changed along the anode length. Our results show the great potential of the BES with enlarged anode and high applied voltages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Efficient Carrier Multiplication in Colloidal Silicon Nanorods

    DOE PAGES

    Stolle, Carl Jackson; Lu, Xiaotang; Yu, Yixuan; ...

    2017-08-01

    In this study, auger recombination lifetimes, absorption cross sections, and the quantum yields of carrier multiplication (CM), or multiexciton generation (MEG), were determined for solvent-dispersed silicon (Si) nanorods using transient absorption spectroscopy (TAS). Nanorods with an average diameter of 7.5 nm and aspect ratios of 6.1, 19.3, and 33.2 were examined. Colloidal Si nanocrystals of similar diameters were also studied for comparison. The nanocrystals and nanorods were passivated with organic ligands by hydrosilylation to prevent surface oxidation and limit the effects of surface trapping of photoexcited carriers. All samples used in the study exhibited relatively efficient photoluminescence. The Auger lifetimesmore » increased with nanorod length, and the nanorods exhibited higher CM quantum yield and efficiency than the nanocrystals with a similar band gap energy E g. Beyond a critical length, the CM quantum yield decreases. Finally, nanorods with the aspect ratio of 19.3 had the highest CM quantum yield of 1.6 ± 0.2 at 2.9E g, which corresponded to a multiexciton yield that was twice as high as observed for the spherical nanocrystals.« less

  4. Excitation-dependent carrier lifetime and diffusion length in bulk CdTe determined by time-resolved optical pump-probe techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ščajev, Patrik; Miasojedovas, Saulius; Mekys, Algirdas

    We applied time-resolved pump-probe spectroscopy based on free carrier absorption and light diffraction on a transient grating for direct measurements of the carrier lifetime and diffusion coefficient D in high-resistivity single crystal CdTe (codoped with In and Er). The bulk carrier lifetime t decreased from 670 +/-50 ns to 60 +/- 10 ns with increase of excess carrier density N from 10 16 to 5 x 10 18cm -3 due to the excitation-dependent radiative recombination rate. In this N range, the carrier diffusion length dropped from 14 um to 6 um due to lifetime decrease. Modeling of in-depth (axial) andmore » in-plane (lateral) carrier diffusion provided the value of surface recombination velocity S = 6 x 10 5 cm/s for the untreated surface. At even higher excitations, in the 10 19-3 x 10 20 cm -3 density range, D increase from 5 to 20 cm^2/s due to carrier degeneracy was observed.« less

  5. Excitation-dependent carrier lifetime and diffusion length in bulk CdTe determined by time-resolved optical pump-probe techniques

    DOE PAGES

    Ščajev, Patrik; Miasojedovas, Saulius; Mekys, Algirdas; ...

    2018-01-14

    We applied time-resolved pump-probe spectroscopy based on free carrier absorption and light diffraction on a transient grating for direct measurements of the carrier lifetime and diffusion coefficient D in high-resistivity single crystal CdTe (codoped with In and Er). The bulk carrier lifetime t decreased from 670 +/-50 ns to 60 +/- 10 ns with increase of excess carrier density N from 10 16 to 5 x 10 18cm -3 due to the excitation-dependent radiative recombination rate. In this N range, the carrier diffusion length dropped from 14 um to 6 um due to lifetime decrease. Modeling of in-depth (axial) andmore » in-plane (lateral) carrier diffusion provided the value of surface recombination velocity S = 6 x 10 5 cm/s for the untreated surface. At even higher excitations, in the 10 19-3 x 10 20 cm -3 density range, D increase from 5 to 20 cm^2/s due to carrier degeneracy was observed.« less

  6. Development of high-density helicon plasma sources and their applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shinohara, Shunjiro; Hada, Tohru; Motomura, Taisei

    2009-05-15

    We report on the development of unique, high-density helicon plasma sources and describe their applications. Characterization of one of the largest helicon plasma sources yet constructed is made. Scalings of the particle production efficiency are derived from various plasma production devices in open literature and our own data from long and short cylinder devices, i.e., high and low values of the aspect ratio A (the ratio of the axial length to the diameter), considering the power balance in the framework of a simple diffusion model. A high plasma production efficiency is demonstrated, and we clarify the structures of the excitedmore » waves in the low A region down to 0.075 (the large device diameter of 73.8 cm with the axial length as short as 5.5 cm). We describe the application to plasma propulsion using a new concept that employs no electrodes. A very small diameter (2.5 cm) helicon plasma with 10{sup 13} cm{sup -3} density is produced, and the preliminary results of electromagnetic plasma acceleration are briefly described.« less

  7. High-speed registration of phonation-related glottal area variation during artificial lengthening of the vocal tract.

    PubMed

    Laukkanen, Anne-Maria; Pulakka, Hannu; Alku, Paavo; Vilkman, Erkki; Hertegård, Stellan; Lindestad, Per-Ake; Larsson, Hans; Granqvist, Svante

    2007-01-01

    Vocal exercises that increase the vocal tract impedance are widely used in voice training and therapy. The present study applies a versatile methodology to investigate phonation during varying artificial extension of the vocal tract. Two males and one female phonated into a hard-walled plastic tube (phi 2 cm), whose physical length was randomly pair-wise changed between 30 cm, 60 cm and 100 cm. High-speed image (1900 f/sec) sequences of the vocal folds were obtained via a rigid endoscope. Acoustic and electroglottographic signals (EGG) were recorded. Oral pressure during shuttering of the tube was used to give an estimate of subglottic pressure (Psub). The only trend observed was that with the two longer tubes compared to the shortest one, fundamental frequency was lower, open time of the glottis shorter, and Psub higher. The results may partly reflect increased vocal tract impedance as such and partly the increased vocal effort to compensate for it. In other parameters there were individual differences in tube length-related changes, suggesting complexity of the coupling between supraglottic space and the glottis.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stolle, Carl Jackson; Lu, Xiaotang; Yu, Yixuan

    In this study, auger recombination lifetimes, absorption cross sections, and the quantum yields of carrier multiplication (CM), or multiexciton generation (MEG), were determined for solvent-dispersed silicon (Si) nanorods using transient absorption spectroscopy (TAS). Nanorods with an average diameter of 7.5 nm and aspect ratios of 6.1, 19.3, and 33.2 were examined. Colloidal Si nanocrystals of similar diameters were also studied for comparison. The nanocrystals and nanorods were passivated with organic ligands by hydrosilylation to prevent surface oxidation and limit the effects of surface trapping of photoexcited carriers. All samples used in the study exhibited relatively efficient photoluminescence. The Auger lifetimesmore » increased with nanorod length, and the nanorods exhibited higher CM quantum yield and efficiency than the nanocrystals with a similar band gap energy E g. Beyond a critical length, the CM quantum yield decreases. Finally, nanorods with the aspect ratio of 19.3 had the highest CM quantum yield of 1.6 ± 0.2 at 2.9E g, which corresponded to a multiexciton yield that was twice as high as observed for the spherical nanocrystals.« less

  9. High-displacement spiral piezoelectric actuators

    NASA Astrophysics Data System (ADS)

    Mohammadi, F.; Kholkin, A. L.; Jadidian, B.; Safari, A.

    1999-10-01

    A high-displacement piezoelectric actuator, employing spiral geometry of a curved piezoelectric strip is described. The monolithic actuators are fabricated using a layered manufacturing technique, fused deposition of ceramics, which is capable of prototyping electroceramic components with complex shapes. The spiral actuators (2-3 cm in diameter) consisted of 4-5 turns of a lead zirconate titanate ceramic strip with an effective length up to 28 cm. The width was varied from 0.9 to 1.75 mm with a height of 3 mm. When driven by the electric field applied across the width of the spiral wall, the tip of the actuator was found to displace in both radial and tangential directions. The tangential displacement of the tip was about 210 μm under the field of 5 kV/cm. Both the displacement and resonant frequency of the spirals could be tailored by changing the effective length and wall width. The blocking force of the actuator in tangential direction was about 1 N under the field of 5 kV/cm. These properties are advantageous for high-displacement low-force applications where bimorph or monomorph actuators are currently employed.

  10. Comparison of preparation of curved root canals with Hyflex CM and Revo-S rotary nickel-titanium instruments.

    PubMed

    Bürklein, S; Börjes, L; Schäfer, E

    2014-05-01

    To compare the shaping ability of three different nickel-titanium rotary instruments during the preparation of curved root canals in extracted teeth. A total of 60 root canals with curvatures ranging between 25° and 35° were divided into three groups of 20 canals. Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the radius of canal curvature. Canals were prepared to a final apical size of 35 using Mtwo, Hyflex CM, and Revo-S. Using pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis program. Preparation time, changes of working length and instrument failures were also recorded. These data were analysed statistically using anova and Student-Newman-Keuls test. During preparation, no file fractured. Mtwo and Hyflex CM maintained the original canal curvature significantly better than Revo-S (P < 0.05). Instrumentation with Mtwo and Hyflex CM was significantly faster than with Revo-S and resulted in less loss of working length (P < 0.05), whilst no significant differences were obtained between Mtwo and Hyflex CM (P > 0.05). Under the conditions of this study, Mtwo and Hyflex CM respected the original canal curvature well and were safe to use. The use of Revo-S instruments required more time to prepare the curved canals and resulted in more pronounced canal straightening compared with Mtwo and Hyflex CM. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  11. [Longitudinal preputial pedicled flap urethroplasty for chordee of Donnahoo type IV].

    PubMed

    Zeng, Li; Shan, Wei; Yuan, Miao; Huang, Guizhen; Huang, Lugang

    2012-11-01

    To investigate the effectiveness of longitudinal preputial pedicled flap urethroplasty for chordee of Donnahoo IV type. Between June 1994 and October 2011, 30 patients with chordee (Donnahoo type IV) underwent longitudinal preputial pedicled flap urethroplasty. The patients' age ranged from 2 to 16 years (mean, 5.8 years). The morphology of the balanus-navicular fossa-external urethral orifice ranged normal; the penis length was 2.5-6.8 cm (mean, 4.3 cm); the penis bending angle was 35-70 degrees (mean, 40.1 degrees). Primary and secondary operation was 27 cases and 3 cases, respectively. The size of flap ranged from 1.5 cm x 1.3 cm to 4.0 cm x 2.0 cm. After correction, the penis length was 3.0-8.5 cm (mean, 6.6 cm); the penis bending angle was 0-10 degrees (mean, 1.2 degrees). All patients were followed up 6 months to 12 years (mean, 33 months). No recurrence, stabbing pain of the balanus, or foreign body sensation occurred during follow-up. Of them, 4 patients (13.33%) had urinary fistular, they had satisfactory results after the second operation; 2 patients (6.67%) had urethral stricture 1 month after operation, they also had satisfactory results after arethral dilatation. The other patients showed no scattering urinary flow and good direction without complication. Six patients had satisfactory sexual function after puberty without erection disorder, pain, or dyspareunia. Longitudinal preputial pedicled flap urethroplasty can achieve maximum utilization of prepuce and aesthetic and functional improvement with less complication, so it is a relatively ideal mean for treating chordee of Donnahoo type IV.

  12. Orally administered betaine reduces photodamage caused by UVB irradiation through the regulation of matrix metalloproteinase-9 activity in hairless mice.

    PubMed

    Im, A-Rang; Lee, Hee Jeong; Youn, Ui Joung; Hyun, Jin Won; Chae, Sungwook

    2016-01-01

    Betaine is widely distributed in plants, microorganisms, in several types of food and in medical herbs, including Lycium chinense. The administration of 100 mg betaine/kg body weight/day is an effective strategy for preventing ultraviolet irradiation‑induced skin damage. The present study aimed to determine the preventive effects of betaine on ultraviolet B (UVB) irradiation‑induced skin damage in hairless mice. The mice were divided into three groups: Control (n=5), UVB‑treated vehicle (n=5) and UVB‑treated betaine (n=5) groups. The level of irradiation was progressively increased between 60 mJ/cm2 per exposure at week 1 (one minimal erythematous dose = 60 mJ/cm2) and 90 mJ/cm2 per exposure at week 7. The formation of wrinkles significantly increased following UVB exposure in the UVB‑treated vehicle group. However, treatment with betaine suppressed UVB‑induced wrinkle formation, as determined by the mean length, mean depth, number, epidermal thickness and collagen damage. Furthermore, oral administration of betaine also inhibited the UVB‑induced expression of mitogen‑activated protein kinase kinase (MEK), extracellular signal‑regulated kinase (ERK), and matrix metalloproteinase‑9 (MMP‑9). These findings suggested that betaine inhibits UVB‑induced skin damage by suppressing increased expression of MMP‑9 through the inhibition of MEK and ERK.

  13. Treatment room length-of-stay and patient throughput with radioiodine thyroid remnant ablation in differentiated thyroid cancer: comparison of thyroid-stimulating hormone stimulation methods.

    PubMed

    Vallejo Casas, Juan Antonio; Mena Bares, Luisa M; Gálvez, María Angeles; Marlowe, Robert J; Latre Romero, José M; Martínez-Paredes, María

    2011-09-01

    We sought to empirically compare treatment room length-of-stay and patient throughput for recombinant human thyroid-stimulating hormone (rhTSH)-aided thyroid remnant ablation with thyroid hormone withdrawal (THW)-aided ablation in patients with differentiated thyroid carcinoma (DTC). We retrospectively reviewed charts of all eligible (near) totally thyroidectomized patients with DTC undergoing ablation and 1-year ablation success evaluation at our tertiary referral centre from January 2003 to February 2009 (N=274). M1 disease caused exclusion unless discovered by a postablation scan or present when rhTSH was the only tolerable stimulation method. We extracted data on the length-of-stay, defined as the time between treatment room admission and discharge, and patient throughput, defined as patients ablated per treatment room per week. The treatment room discharge criterion was a whole-body dose rate of less than 60 μSv/h at 50 cm. The treatment groups (rhTSH, n=187; THW, n=87) had mostly statistically similar characteristics, but differed in primary tumour status distribution. In addition, at ablation, the rhTSH patients had a greater prevalence of prior diagnostic scintigraphy, higher mean serum TSH, and shorter interval since surgery, and received a 5.6% larger mean ablation activity. On average, rhTSH patients had a significantly lower peak whole-body dose rate (57.1 vs. 83.4 μSv/h at 50 cm; P<0.0001) and a significantly shorter treatment room stay than did the THW patients (1.41 vs. 2.02 days; P<0.001). rhTSH use allowed significantly more patients to be ablated per room per week (2.7 vs. 1.2; P<0.001). Relative to THW, rhTSH use to aid ablation reduced mean treatment room length-of-stay by almost one-third and more than doubled the average weekly patient throughput, both of which were significant differences.

  14. Overestimation of femoral tunnel length during anterior cruciate ligament reconstruction using the retrograde outside-in drilling technique.

    PubMed

    Okazaki, Ken; Osaki, Kanji; Nishikawa, Kazutaka; Matsubara, Hirokazu; Tashiro, Yasutaka; Iwamoto, Yukihide

    2016-08-01

    When the femoral tunnel socket is reamed in an oblique direction from the wall of inter-condylar notch in anterior cruciate ligament (ACL) reconstruction, the tunnel length can be shorter at the periphery than at the centre. Because surgeons can manipulate the direction of tunnel in the outside-in femoral tunnel drilling technique, this length mismatch would vary depending on the direction of the tunnel. The purpose of this study was to investigate this length mismatch when reamed in various directions. In total of thirteen points were defined as femoral drilling entry points on concentric lines with 0, 1, 2, and 3 cm radius from the lateral epicondyle of a three-dimensional bone model from 40 subjects. Femoral tunnel drilling was simulated on the models by connecting the centre of the ACL footprint with each defined point on the lateral femoral surface. The mismatch length was measured between the centre and the shortest peripheral side of the tunnel socket. When the distance between the drilling entry point on the lateral femoral surface and the lateral epicondyle was increased to anterior proximal direction, there was a significant increase in the mismatch length. The mismatch length became more than 2 mm when the entry point was located more than 2 cm away from the lateral epicondyle. When the drilling entry point is set far away from the lateral epicondyle, a significant increase was observed in tunnel length mismatch between the centre of the tunnel and its shortest peripheral side. Because the tunnel length is measured with a guide pin introduced at the centre of the tunnel before reaming in retrograde outside-in technique, this length mismatch could cause an overestimation of the tunnel length. Surgeons should recognise this mismatch when preparing the length of graft and socket to optimise the graft insertion length into the socket.

  15. NASA Subsonic Jet Transport Noise Reduction Research

    DTIC Science & Technology

    2000-09-01

    optical and acoustical interference. Figure 7 shows the concept and data from the installation of arrays of Herschel- Quincke tubes in the duct...tube row 16 tube row Herschel- Quincke Tube Tube length 12.5cm d = 3.8cm L = 9.2cm 2250 2350 2450 2500...Blade passage frequency, Hz R el at iv e p o w er , d B JT15D Turbofan Engine 4 d B Figure 7. Application of Herschel- Quincke tubes for

  16. Generation of Bright Phase-matched Circularly-polarized Extreme Ultraviolet High Harmonics

    DTIC Science & Technology

    2014-12-08

    circularly-polarized laser pulses field-ionize a gas in a hollow - core waveguide. We use this new light source for magnetic circular dichroism...polarized with opposite helicity in a gas-filled hollow waveguide (see Supplementary Section 6 for details on the important features of this source...mJ/pulse) driving lasers are focused into a 150-µm-diameter, 2-cm-long gas-filled hollow waveguide using lenses with focal lengths of 50 cm and 75 cm

  17. 77 FR 21679 - Shrimp Fisheries of the Gulf of Mexico and South Atlantic; Revisions of Bycatch Reduction Device...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-11

    ... extension, the BRD escape openings must be no more than 5\\1/2\\ meshes from the posterior edge of the grid... read as follows: Authority: 16 U.S.C. 1801 et seq. 0 2. In Sec. 622.34, the second sentence of... constructed of \\5/16\\-inch (0.79-cm) or \\3/8\\-inch (0.95-cm) cable 34\\1/2\\ inches (87.6 cm) in length. The...

  18. Hamstring Injuries in Professional Soccer Players: Extent of MRI-Detected Edema and the Time to Return to Play.

    PubMed

    Crema, Michel D; Godoy, Ivan R B; Abdalla, Rene J; de Aquino, Jose Sanchez; Ingham, Sheila J McNeill; Skaf, Abdalla Y

    Discrepancies exist in the literature regarding the association of the extent of injuries assessed on magnetic resonance imaging (MRI) with recovery times. MRI-detected edema in grade 1 hamstring injuries does not affect the return to play (RTP). Retrospective cohort study. Level 4. Grade 1 hamstring injuries from 22 professional soccer players were retrospectively reviewed. The extent of edema-like changes on fluid-sensitive sequences from 1.5-T MRI were evaluated using craniocaudal length, percentage of cross-sectional area, and volume. The time needed to RTP was the outcome. Negative binomial regression analysis tested the measurements of MRI-detected edema-like changes as prognostic factors. The mean craniocaudal length was 7.6 cm (SD, 4.9 cm; range, 0.9-19.1 cm), the mean percentage of cross-sectional area was 23.6% (SD, 20%; range, 4.4%-89.6%), and the mean volume was 33.1 cm 3 (SD, 42.6 cm 3 ; range, 1.1-161.3 cm 3 ). The mean time needed to RTP was 13.6 days (SD, 8.9 days; range, 3-32 days). None of the parameters of extent was associated with RTP. The extent of MRI edema in hamstring injuries does not have prognostic value. Measuring the extent of edema in hamstring injuries using MRI does not add prognostic value in clinical practice.

  19. Simple Anchoring of the Penopubic Skin to the Prepubic Deep Fascia in Surgical Correction of Buried Penis

    PubMed Central

    Jung, Eun-hong; Jang, Seok-heun; Lee, Jae-won

    2011-01-01

    Purpose The aim of this study was to categorize concealed penis and buried penis by preoperative physical examination including the manual prepubic compression test and to describe a simple surgical technique to correct buried penis that was based on surgical experience and comprehension of the anatomical components. Materials and Methods From March 2007 to November 2010, 17 patients were diagnosed with buried penis after differentiation of this condition from concealed penis. The described surgical technique consisted of a minimal incision and simple fixation of the penile shaft skin and superficial fascia to the prepubic deep fascia, without degloving the penile skin. Results The mean age of the patients was 10.2 years, ranging from 8 years to 15 years. The median follow-up was 19 months (range, 5 to 49 months). The mean penile lengths were 1.8 cm (range, 1.1 to 2.5 cm) preoperatively and 4.5 cm (range, 3.3 to 5.8 cm) postoperatively. The median difference between preoperative and postoperative penile lengths was 2.7 cm (range, 2.1 to 3.9 cm). There were no serious intra- or postoperative complications. Conclusions With the simple anchoring of the penopubic skin to the prepubic deep fascia, we obtained successful subjective and objective outcomes without complications. We suggest that this is a promising surgical method for selected patients with buried penis. PMID:22195270

  20. Volumetric Growth of the Liver in the Human Fetus: An Anatomical, Hydrostatic, and Statistical Study.

    PubMed

    Szpinda, Michał; Paruszewska-Achtel, Monika; Woźniak, Alina; Mila-Kierzenkowska, Celestyna; Elminowska-Wenda, Gabriela; Dombek, Małgorzata; Szpinda, Anna; Badura, Mateusz

    2015-01-01

    Using anatomical, hydrostatic, and statistical methods, liver volumes were assessed in 69 human fetuses of both sexes aged 18-30 weeks. No sex differences were found. The median of liver volume achieved by hydrostatic measurements increased from 6.57 cm(3) at 18-21 weeks through 14.36 cm(3) at 22-25 weeks to 20.77 cm(3) at 26-30 weeks, according to the following regression: y = -26.95 + 1.74 × age ± Z × (-3.15 + 0.27 × age). The median of liver volume calculated indirectly according to the formula liver volume = 0.55 × liver length × liver transverse diameter × liver sagittal diameter increased from 12.41 cm(3) at 18-21 weeks through 28.21 cm(3) at 22-25 weeks to 49.69 cm(3) at 26-30 weeks. There was a strong relationship (r = 0.91, p < 0.001) between the liver volumes achieved by hydrostatic (x) and indirect (y) methods, expressed by y = -0.05 + 2.16x ± 7.26. The liver volume should be calculated as follows liver volume = 0.26 × liver length × liver transverse diameter × liver sagittal diameter. The age-specific liver volumes are of great relevance in the evaluation of the normal hepatic growth and the early diagnosis of fetal micro- and macrosomias.

  1. Vocal cords-carina distance in anaesthetised Caucasian adults and its clinical implications for tracheal intubation.

    PubMed

    Pang, G; Edwards, M J; Greenland, K B

    2010-11-01

    Previous work has assessed vocal cords-carina distance in Chinese patients and compared it to commonly used tracheal tubes. In addition, an attempt was made to identify surface anatomy measurements with short tracheas. We have examined the length of tracheas in Caucasian patients and compared it with currently used tracheal tubes. We have investigated a wider range of surface anatomy measurements in an attempt to correlate measurements with vocal cords-carina distance and identifying patients who may be at risk of endobronchial intubation. In this study, the vocal cords-carina distance was measured in 150 anaesthetised Caucasian patients with a fibreoptic bronchoscope. We also attempted to correlate height and various surface anatomy measurements on the patients' chest, neck and limb regions to predict those patients at risk of endobronchial intubation. The mean vocal cords-carina distance was 12.7 cm (standard deviation 1.6 cm). The best predictors in our study of vocal cords-carina distance less than 11.3 cm were a height of < or = 182 cm, an ulnar length of < or = 31.2 cm or a thyroid to xiphisternum distance of < or = 31.8 cm. This correlation is poor however and prediction of vocal cords-carina distance remains difficult clinically. It was therefore concluded that surface anatomy measurements are a poor predictor of vocal cords-carina distance.

  2. Using Point Clouds Generated from Unmanned Aerial Vehicles Imagery Processed with Structure from Motion to Address Tsunami vs Storm Wave Boulder Deposition in Watu Karung, Indonesia

    NASA Astrophysics Data System (ADS)

    Uribe, A. T.; Bunds, M. P.; Andreini, J.; Horns, D. M.; Harris, R. A.; Prasetyadi, C.; Yulianto, E.; Putra, P. S.

    2017-12-01

    Tsunamis pose a major hazard to coastal communities along the south coast of much of Indonesia due its location on the Australian-Sunda arc. Furthermore, tsunamis and high-energy wave events are the principal drivers of geomorphic change in the area and it is difficult to distinguish the effects of each. A potentially useful indicator of past tsunami activity is coastal imbricated boulder deposits. To address whether an imbricated boulder deposit located on a beach in Watu Karung (Java, Indonesia) could have been formed by non-tsunami wave activity and to investigate coastal geomorphic change, we generated three pairs of digital surface models (DSMs) over an approximately one year period using photographs taken from a small unmanned aerial vehicle and structure-from-motion photogrammetry. The first two DSMs were made from photographs taken on 7/30-31/2016 and 8/2/2016, immediately before and after a significant 4.2 m swell struck the beach during a +2.5 m spring high tide. The third DSM pair was made from imagery collected 7/12/2017. Each pair of DSMs consists of a 1 cm pixel DSM of the boulder deposit and a 4 cm DSM of the larger beach area that surrounds the boulders. In addition, prior to the 2016 wave event 21 boulders up to 75 kg were marked and hand-placed shoreward of the boulder deposit; their movement was tracked with RTK GPS measurements. In the 2016 wave event, every hand-placed boulder moved, with an average displacement of 27.6 m. At the same time, approximately 20 of 650 naturally - occurring boulders, up to 2 m in length, moved more than 10 cm and up to 5.6 m. Between 2016 and 2017, approximately 300 of 650 naturally - occurring boulders with an average length of 1.6 m moved varying distances of at least 10 cm and up to 30 m. In addition, changes in beach sand volume occurred in ten 25 m2 localized zones on the beach with an average volume change of approximately 65 m2. Changes in both boulder position and sand volume occurred during the 2016 to 2017 time period when no tsunamis affected Watu Karung—thus indicating that all changes were the result of storm wave events.

  3. Simple, safe, and satisfactory secondary penile enhancement after near-total oncologic amputation.

    PubMed

    Hage, J Joris

    2009-06-01

    After oncologic penile amputation, the penile stump may prove of insufficient length, causing poor personal hygiene and scrotal excoriation and an inability to void while standing. In these cases, penile enhancement by uncovering its subcutaneous parts may offer a simple and satisfactory solution.From August 2003 to August 2007, penile enhancement was performed in 6 patients with a mean age of 63 years (range, 51-69 years) and only 1 cm (range, 0-1.5 cm) of remaining penile length when standing up.The skin on the penile stump was used to recreate a neoglans. The subcutaneously covered penile shaft was dissected deep to Buck's fascia up into the deep suspensory ligament. Ventrally, the bulbospongeous muscle was laid bare over 1 to 2 cm. After resection of pubic subcutaneous fat, the pubic and scrotal skin edges were anchored to the suspensory ligament, bulbospongious fascia, and tunica albuginea. The resulting bare surface of the penile shaft was covered by a skin graft.Partial neoglandular skin slough was observed in 2 patients and could be treated conservatively in both. Penile lymphedema was observed in the 1 patient whom had previously undergone radiotherapy. This was treated by secondary subcutaneous resection and skin tightening. At a mean follow-up of 2.5 years (range, 1-5 years), the cosmetic appearance was acceptable in all patients and their penile length ranged from 7.5 to 9 cm. All were able to void while standing without soiling themselves.

  4. Age, Growth, Reproduction and Feeding of the Spurdog ( Squalus acanthias Linnaeus, 1758) in the South-eastern Black Sea

    NASA Astrophysics Data System (ADS)

    Avsar, D.

    2001-02-01

    Life-history parameters and diet of spurdog ( Squalus acanthias) sampled from the SE Black Sea were studied. Spurdog from age classes I to XIV were identified, with a dominance of age class VIII for both sexes. The length-weight relationship was W=0·0040*L 2·95and the mean annual growth rates in length and weight were 7·2 cm and 540·1 g, respectively. The estimated von Bertalanffy growth parameters were: W ∞=12021 (g), L ∞=157 (cm), K=0·12 (year -1) and t 0=-1·30 (year). The size at first maturity was 82 cm for males and 88 cm for females. Mean biennial fecundity was also found to be 8 pups/female. The relationships between fecundity-length, fecundity-weight and fecundity-age were found to be: F=-17·0842+0·2369*L (R=0·93), F=0·3780+0·0018*W (R=0·89) and F =-0·7859+1·1609*A (R=0·94) respectively. The spurdog can be considered an opportunistic feeder. Their natural diet was composed mainly of teleost fishes, followed by Crustaceans, Nematodes and Actinarians (=sea anemones). Whiting ( Merlangius merlangus euxinus) was the predominant prey item among their fish prey. Demersal teleosts formed the majority of the diet, and there was no difference ( P>0·05) among the food items of immature, maturing and mature individuals of both sexes.

  5. Quantitative Infrared Image Analysis Of Simultaneous Upstream and Downstream Microgravity Flame Spread over Thermally-Thin Cellulose in Low Speed Forced Flow

    NASA Technical Reports Server (NTRS)

    Olson, S. L.; Lee, J. R.; Fujita, O.; Kikuchi, M.; Kashiwagi, T.

    2013-01-01

    The effect of low velocity forced flow on microgravity flame spread is examined using quantitative analysis of infrared video imaging. The objective of the quantitative analysis is to provide insight into the mechanisms of flame spread in microgravity where the flame is able to spread from a central location on the fuel surface, rather than from an edge. Surface view calibrated infrared images of ignition and flame spread over a thin cellulose fuel were obtained along with a color video of the surface view and color images of the edge view using 35 mm color film at 2 Hz. The cellulose fuel samples were mounted in the center of a 12 cm wide by 16 cm tall flow duct and were ignited in microgravity using a straight hot wire across the center of the 7.5 cm wide by 14 cm long samples. Four cases, at 1 atm. 35%O2 in N2, at forced flows from 2 cm/s to 20 cm/s are presented here. This flow range captures flame spread from strictly upstream spread at low flows, to predominantly downstream spread at high flow. Surface temperature profiles are evaluated as a function of time, and temperature gradients for upstream and downstream flame spread are measured. Flame spread rates from IR image data are compared to visible image spread rate data. IR blackbody temperatures are compared to surface thermocouple readings to evaluate the effective emissivity of the pyrolyzing surface. Preheat lengths and pyrolysis lengths are evaluated both upstream and downstream of the central ignition point. A surface energy balance estimates the net heat flux from the flame to the fuel surface along the length of the fuel. Surface radiative loss and gas-phase radiation from soot are measured relative to the net heat feedback from the flame. At high surface heat loss relative to heat feedback, the downstream flame spread does not occur.

  6. GATE Simulations of Small Animal SPECT for Determination of Scatter Fraction as a Function of Object Size

    NASA Astrophysics Data System (ADS)

    Konik, Arda; Madsen, Mark T.; Sunderland, John J.

    2012-10-01

    In human emission tomography, combined PET/CT and SPECT/CT cameras provide accurate attenuation maps for sophisticated scatter and attenuation corrections. Having proven their potential, these scanners are being adapted for small animal imaging using similar correction approaches. However, attenuation and scatter effects in small animal imaging are substantially less than in human imaging. Hence, the value of sophisticated corrections is not obvious for small animal imaging considering the additional cost and complexity of these methods. In this study, using GATE Monte Carlo package, we simulated the Inveon small animal SPECT (single pinhole collimator) scanner to find the scatter fractions of various sizes of the NEMA-mouse (diameter: 2-5.5 cm , length: 7 cm), NEMA-rat (diameter: 3-5.5 cm, length: 15 cm) and MOBY (diameter: 2.1-5.5 cm, length: 3.5-9.1 cm) phantoms. The simulations were performed for three radionuclides commonly used in small animal SPECT studies:99mTc (140 keV), 111In (171 keV 90% and 245 keV 94%) and 125I (effective 27.5 keV). For the MOBY phantoms, the total Compton scatter fractions ranged (over the range of phantom sizes) from 4-10% for 99mTc (126-154 keV), 7-16% for 111In (154-188 keV), 3-7% for 111In (220-270 keV) and 17-30% for 125I (15-45 keV) including the scatter contributions from the tungsten collimator, lead shield and air (inside and outside the camera heads). For the NEMA-rat phantoms, the scatter fractions ranged from 10-15% (99mTc), 17-23% 111In: 154-188 keV), 8-12% (111In: 220-270 keV) and 32-40% (125I). Our results suggest that energy window methods based on solely emission data are sufficient for all mouse and most rat studies for 99mTc and 111In. However, more sophisticated methods may be needed for 125I.

  7. Using specific length amplified fragment sequencing to construct the high-density genetic map for Vitis (Vitis vinifera L. × Vitis amurensis Rupr.).

    PubMed

    Guo, Yinshan; Shi, Guangli; Liu, Zhendong; Zhao, Yuhui; Yang, Xiaoxu; Zhu, Junchi; Li, Kun; Guo, Xiuwu

    2015-01-01

    In this study, 149 F1 plants from the interspecific cross between 'Red Globe' (Vitis vinifera L.) and 'Shuangyou' (Vitis amurensis Rupr.) and the parent were used to construct a molecular genetic linkage map by using the specific length amplified fragment sequencing technique. DNA sequencing generated 41.282 Gb data consisting of 206,411,693 paired-end reads. The average sequencing depths were 68.35 for 'Red Globe,' 63.65 for 'Shuangyou,' and 8.01 for each progeny. In all, 115,629 high-quality specific length amplified fragments were detected, of which 42,279 were polymorphic. The genetic map was constructed using 7,199 of these polymorphic markers. These polymorphic markers were assigned to 19 linkage groups; the total length of the map was 1929.13 cm, with an average distance of 0.28 cm between each maker. To our knowledge, the genetic maps constructed in this study contain the largest number of molecular markers. These high-density genetic maps might form the basis for the fine quantitative trait loci mapping and molecular-assisted breeding of grape.

  8. Separation of delta-, gamma- and alpha-tocopherols by CEC.

    PubMed

    Fanali, Salvatore; Catarcini, Paolo; Quaglia, Maria Giovanna; Camera, Emanuela; Rinaldi, Mariarosa; Picardo, Mauro

    2002-08-01

    In this study capillary electrochromatography (CEC) was used for the separation of three tocopherols (TOHs), namely delta-, gamma- and alpha-TOH and the antioxidant compound, butylated hydroxytoluene (BHT). The CEC experiments were carried out using an octadecylsilica (ODS) stationary phase packed, in our laboratory, in a fused-silica capillary (100 microm I.D., 365 microm O.D. x 33 cm of total length and 24.6 or 8.4 cm effective length). The mobile phase was composed by a mixture of methanol (MeOH) and acetonitrile (ACN), at different concentrations and 0.01% (w/v) of ammonium acetate. Retention time (t(R)), retention factor (k), resolution (R(s)) of the three TOHs were strongly influenced by the organic solvent composition of the run buffer and by the effective length of the capillary. Optimum experimental conditions were found even employing the short effective length of the capillary achieving the baseline separation of the studied analytes in a relatively short time (less than 5 min). The optimized method was applied to the qualitative analysis of vitamin E (alpha-TOH) present in a human serum extract.

  9. Associations between birth size and later height from infancy through adulthood: An individual based pooled analysis of 28 twin cohorts participating in the CODATwins project.

    PubMed

    Jelenkovic, Aline; Yokoyama, Yoshie; Sund, Reijo; Hur, Yoon-Mi; Harris, Jennifer R; Brandt, Ingunn; Nilsen, Thomas Sevenius; Ooki, Syuichi; Ullemar, Vilhelmina; Almqvist, Catarina; Magnusson, Patrik K E; Saudino, Kimberly J; Stazi, Maria A; Fagnani, Corrado; Brescianini, Sonia; Nelson, Tracy L; Whitfield, Keith E; Knafo-Noam, Ariel; Mankuta, David; Abramson, Lior; Cutler, Tessa L; Hopper, John L; Llewellyn, Clare H; Fisher, Abigail; Corley, Robin P; Huibregtse, Brooke M; Derom, Catherine A; Vlietinck, Robert F; Bjerregaard-Andersen, Morten; Beck-Nielsen, Henning; Sodemann, Morten; Krueger, Robert F; McGue, Matt; Pahlen, Shandell; Alexandra Burt, S; Klump, Kelly L; Dubois, Lise; Boivin, Michel; Brendgen, Mara; Dionne, Ginette; Vitaro, Frank; Willemsen, Gonneke; Bartels, Meike; van Beijsterveld, Catharina E M; Craig, Jeffrey M; Saffery, Richard; Rasmussen, Finn; Tynelius, Per; Heikkilä, Kauko; Pietiläinen, Kirsi H; Bayasgalan, Gombojav; Narandalai, Danshiitsoodol; Haworth, Claire M A; Plomin, Robert; Ji, Fuling; Ning, Feng; Pang, Zengchang; Rebato, Esther; Tarnoki, Adam D; Tarnoki, David L; Kim, Jina; Lee, Jooyeon; Lee, Sooji; Sung, Joohon; Loos, Ruth J F; Boomsma, Dorret I; Sørensen, Thorkild I A; Kaprio, Jaakko; Silventoinen, Karri

    2018-05-01

    There is evidence that birth size is positively associated with height in later life, but it remains unclear whether this is explained by genetic factors or the intrauterine environment. To analyze the associations of birth weight, length and ponderal index with height from infancy through adulthood within mono- and dizygotic twin pairs, which provides insights into the role of genetic and environmental individual-specific factors. This study is based on the data from 28 twin cohorts in 17 countries. The pooled data included 41,852 complete twin pairs (55% monozygotic and 45% same-sex dizygotic) with information on birth weight and a total of 112,409 paired height measurements at ages ranging from 1 to 69 years. Birth length was available for 19,881 complete twin pairs, with a total of 72,692 paired height measurements. The association between birth size and later height was analyzed at both the individual and within-pair level by linear regression analyses. Within twin pairs, regression coefficients showed that a 1-kg increase in birth weight and a 1-cm increase in birth length were associated with 1.14-4.25 cm and 0.18-0.90 cm taller height, respectively. The magnitude of the associations was generally greater within dizygotic than within monozygotic twin pairs, and this difference between zygosities was more pronounced for birth length. Both genetic and individual-specific environmental factors play a role in the association between birth size and later height from infancy to adulthood, with a larger role for genetics in the association with birth length than with birth weight. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Maize varieties released in different eras have similar root length density distributions in the soil, which are negatively correlated with local concentrations of soil mineral nitrogen.

    PubMed

    Ning, Peng; Li, Sa; White, Philip J; Li, Chunjian

    2015-01-01

    Larger, and deeper, root systems of new maize varieties, compared to older varieties, are thought to have enabled improved acquisition of soil resources and, consequently, greater grain yields. To compare the spatial distributions of the root systems of new and old maize varieties and their relationships with spatial variations in soil concentrations of available nitrogen (N), phosphorus (P) and potassium (K), two years of field experiments were performed using six Chinese maize varieties released in different eras. Vertical distributions of roots, and available N, P and K in the 0-60 cm soil profile were determined in excavated soil monoliths at silking and maturity. The results demonstrated that new maize varieties had larger root dry weight, higher grain yield and greater nutrient accumulation than older varieties. All varieties had similar total root length and vertical root distribution at silking, but newer varieties maintained greater total root length and had more roots in the 30-60 cm soil layers at maturity. The spatial variation of soil mineral N (Nmin) in each soil horizon was larger than that of Olsen-P and ammonium-acetate-extractable K, and was inversely correlated with root length density (RLD), especially in the 0-20 cm soil layer. It was concluded that greater acquisition of mineral nutrients and higher yields of newer varieties were associated with greater total root length at maturity. The negative relationship between RLD and soil Nmin at harvest for all varieties suggests the importance of the spatial distribution of the root system for N uptake by maize.

  11. Effect of hoof boots and toe-extension shoes on the forelimb kinetics of horses during walking.

    PubMed

    Amitrano, Fernando N; Gutierrez-Nibeyro, Santiago D; Schaeffer, David J

    2016-05-01

    OBJECTIVE To determine and compare the effect of hoof boots (HBs) and shoes with a toe extension on stance duration, ground reaction force, and sole length in contact with the ground in nonlame horses during walking. ANIMALS 6 nonlame Standardbreds. PROCEDURES Force plate gait analyses of the forelimbs were performed while the horses were walking barefoot before manipulation of feet (baseline), while the horses were walking fitted with HBs, while the horses were walking shod with toe-extension shoes, and while the horses were walking barefoot after shoe removal. Horses underwent radiography of both forelimb feet to determine the sole length in contact with the ground when barefoot, wearing HBs, and shod with toe-extension shoes. Stance duration, ground reaction force, and sole length were compared among the various walking sessions. RESULTS Compared with baseline findings, stance duration increased significantly when horses were fitted with HBs (7%) or toe-extension shoes (5%). Peak forelimb ground reaction force was similar among walking sessions; however, time of braking force peak was significantly greater during the stance phase only when horses wore HBs. Also, the sole length in contact with the ground was significantly longer in horses fitted with HBs (14.3 cm) or shod with the toe-extension shoes (17.6 cm), compared with that for one of the barefoot hooves (12.7 cm). CONCLUSIONS AND CLINICAL RELEVANCE In nonlame horses, use of HBs prolonged the stance time and time of braking force peak, which is indicative of a slower deceleration phase during limb impact with the ground. Also, the use of HBs prolonged the deceleration phase of the stride and increased the sole length in contact with the ground.

  12. Maize Varieties Released in Different Eras Have Similar Root Length Density Distributions in the Soil, Which Are Negatively Correlated with Local Concentrations of Soil Mineral Nitrogen

    PubMed Central

    Ning, Peng; Li, Sa; White, Philip J.; Li, Chunjian

    2015-01-01

    Larger, and deeper, root systems of new maize varieties, compared to older varieties, are thought to have enabled improved acquisition of soil resources and, consequently, greater grain yields. To compare the spatial distributions of the root systems of new and old maize varieties and their relationships with spatial variations in soil concentrations of available nitrogen (N), phosphorus (P) and potassium (K), two years of field experiments were performed using six Chinese maize varieties released in different eras. Vertical distributions of roots, and available N, P and K in the 0–60 cm soil profile were determined in excavated soil monoliths at silking and maturity. The results demonstrated that new maize varieties had larger root dry weight, higher grain yield and greater nutrient accumulation than older varieties. All varieties had similar total root length and vertical root distribution at silking, but newer varieties maintained greater total root length and had more roots in the 30–60 cm soil layers at maturity. The spatial variation of soil mineral N (Nmin) in each soil horizon was larger than that of Olsen-P and ammonium-acetate-extractable K, and was inversely correlated with root length density (RLD), especially in the 0–20 cm soil layer. It was concluded that greater acquisition of mineral nutrients and higher yields of newer varieties were associated with greater total root length at maturity. The negative relationship between RLD and soil Nmin at harvest for all varieties suggests the importance of the spatial distribution of the root system for N uptake by maize. PMID:25799291

  13. Effects of atmospheric nonthermal plasma on invasion of colorectal cancer cells

    NASA Astrophysics Data System (ADS)

    Kim, Chul-Ho; Kwon, Seyeoul; Bahn, Jae Hoon; Lee, Keunho; Jun, Seung Ik; Rack, Philip D.; Baek, Seung Joon

    2010-06-01

    The effect that the gas content and plasma power of atmospheric, nonthermal plasma has on the invasion activity in colorectal cancer cells has been studied. Helium and helium plus oxygen plasmas were induced through a nozzle and operated with an ac power of less than 10 kV which exhibited a length of 2.5 cm and a diameter of 3-4 mm in ambient air. Treatment of cancer cells with the plasma jet resulted in a decrease in cell migration/invasion with higher plasma intensity and the addition of oxygen to the He flow gas.

  14. Cutaneous Emergence of Eustrongylides in Two Persons from South Sudan

    PubMed Central

    Eberhard, Mark L.; Ruiz-Tiben, Ernesto

    2014-01-01

    Two large, living worms were collected as they emerged from the lower limb of each of two persons in South Sudan. The worms were observed by staff of the South Sudan Guinea Worm Eradication Program during surveillance activities in communities at-risk for cases of Guinea worm disease (dracunculiasis). The worms measured 7 and 8 cm in length and were identified as fourth-stage larvae of Eustrongylides. This is the first report of such worms emerging from the skin; all five previous reports of human infection involved surgical removal of worms from the peritoneal cavity. PMID:24379241

  15. Neodymium-doped phosphate fiber lasers with an all-solid microstructured inner cladding.

    PubMed

    Zhang, Guang; Zhou, Qinling; Yu, Chunlei; Hu, Lili; Chen, Danping

    2012-06-15

    We report on high-power fiber lasers based on index-guiding, all-solid neodymium-doped (Nd-doped) phosphate photonic crystal fiber (PCF) with a hexagonal-shaped inner cladding. The optimum fiber laser with a 36 cm length active fiber, generated up to 7.92 W output power at 1053 nm, which benefited from a high absorption coefficient for pump power due to its noncircular inner cladding. The guiding properties of the all-solid PCF were also investigated. A stable mode with a donut-shaped profile and a power-dependent laser beam quality have been observed experimentally and analyzed.

  16. Reproductive biology of cuckoo ray Leucoraja naevus.

    PubMed

    Maia, C; Erzini, K; Serra-Pereira, B; Figueiredo, I

    2012-09-01

    The present study is the first to provide data on the reproductive biology of cuckoo ray Leucoraja naevus in Portuguese continental waters. No difference in size at maturity was detected between sexes, which was estimated as 56 cm total length. Spawning occurs all year round, but maximum activity was during winter months. Maximum fecundity is c. 63 eggs female(-1) year(-1). Encapsulated eggs are released in batches, nine in total with a mean number of seven extruded eggs in each batch. © 2012 The Authors. Journal of Fish Biology © 2012 The Fisheries Society of the British Isles.

  17. Maternal height and length of gestation: does this impact on preterm labour in Asian women?

    PubMed

    Chan, Ben Chong-Pun; Lao, Terence Tzu-Hsi

    2009-08-01

    Both maternal height and ethnicity may influence the gestation length, but their independent effect is unclear. This study was performed to examine the relationship between maternal height and gestational length in women with singleton pregnancies in a Chinese and southeast Asian population. A retrospective cohort study was performed on women carrying singleton pregnancies with spontaneous labour in a 48-month period managed under our department to determine the relationship between maternal height, expressed in quartiles, with the mean gestational age and incidence of preterm labour. Of the 16 384 women who delivered within this period, the 25th, 50th and 75th percentile values of maternal height were 153 cm, 156 cm and 160 cm respectively. Excluded from analysis were 6597 women because of multifetal pregnancy, teenage pregnancy (maternal age < or = 19 years old), induction of labour or elective caesarean section, or incomplete data due to no antenatal booking in our hospital. Significant differences were found in the maternal weight and body mass index, incidences of multiparity and smokers, gestational age and birthweight among the four quartiles. There was significantly increased incidence of preterm birth between 32 and 37 weeks gestation in women with shorter stature. In our population, maternal height has an influence on gestational length, and the lower three quartiles was associated with increased odds of labour at > 32 to < 37 weeks. This effect should be taken into consideration in the adoption of international recommendations in obstetric management and intervention.

  18. Key performance indicators in intensive care medicine. A retrospective matched cohort study.

    PubMed

    Kastrup, M; von Dossow, V; Seeling, M; Ahlborn, R; Tamarkin, A; Conroy, P; Boemke, W; Wernecke, K-D; Spies, Claudia

    2009-01-01

    Expert panel consensus was used to develop evidence-based process indicators that were independent risk factors for the main clinical outcome parameters of length of stay in the intensive care unit (ICU) and mortality. In a retrospective, matched data analysis of patients from five ICUs at a tertiary university hospital, agreed process indicators (sedation monitoring, pain monitoring, mean arterial pressure [MAP] >or= 60 mmHg, tidal volume [TV] or= 80 and or= 60 mmHg and BG >or= 80 mg/dl were relevant for survival. Linear regression of the 634 patients showed that analgesia monitoring, PIP or= 60 mmHg, BG >or= 80 mg/dl and

  19. Polymer thermal optical switch for a flexible photonic circuit.

    PubMed

    Sun, Yue; Cao, Yue; Wang, Qi; Yi, Yunji; Sun, Xiaoqiang; Wu, Yuanda; Wang, Fei; Zhang, Daming

    2018-01-01

    Flexible and wearable optoelectronic devices are the new trend for an active lifestyle. These devices are polymer-based for flexibility. We demonstrated flexible polymer waveguide optical switches for a flexible photonic integrated circuit. The optical switches are composed of a single-mode inverted waveguide with dimensions of 5 μm waveguide width, 3 μm ridge height, and 3 μm slab height. A Mach-Zehnder structure was used in the device, with the Y-branch horizontal length of 0.1 cm, the distance between two heating branches of 30 μm, and the heating branch length of 1 cm. The optical field of the device was simulated by beam propagation to optimize the electrode position. The switching properties of the flexible optical switch with different working conditions, such as contact to the polymer, silicon, and skin, were simulated. The device was prepared based on the photo curved polymer and lithography method. The end faces of the flexible film device were processed using an excimer laser with optimized parameters of 28  mJ/cm 2 and 15 Hz. The response rise time and fall time on the PMMA substrate were measured as 1.98 ms and 2.71 ms, respectively. The power consumption was 16 mW and the extinction ratio was 11 dB. The response rise and fall times on the Si substrate were measured as 1.08 ms and 1.62 ms, respectively. The power consumption was 17 mW and the extinction ratio was 11 dB. The demonstrated properties indicate that this flexible optical waveguide structure can be used in the light control area of a wearable device.

  20. Amorphous and crystalline TiO2 nanotube arrays for enhanced Li-ion intercalation properties.

    PubMed

    Guan, Dongsheng; Cai, Chuan; Wang, Ying

    2011-04-01

    We have employed a simple process of anodizing Ti foils to prepare TiO2 nanotube arrays which show enhanced electrochemical properties for applications as Li-ion battery electrode materials. The lengths and pore diameters of TiO2 nanotubes can be finely tuned by varying voltage, electrolyte composition, or anodization time. The as-prepared nanotubes are amorphous and can be converted into anatase nanotubes with heat treatment at 480 degrees C. Rutile crystallites emerge in the anatase nanotube when the annealing temperature is increased to 580 degrees C, resulting in TiO2 nanotubes of mixed phases. The morphological features of nanotubes remain unchanged after annealing. Li-ion insertion performance has been studied for amorphous and crystalline TiO2 nanotube arrays. Amorphous nanotubes with a length of 3.0 microm and an outer diameter of 125 nm deliver a capacity of 91.2 microA h cm(-2) at a current density of 400 microA cm(-2), while those with a length of 25 microm and an outer diameter of 158 nm display a capacity of 533 microA h cm-2. When the 3-microm long nanotubes become crystalline, they deliver lower capacities: the anatase nanotubes and nanotubes of mixed phases show capacities of 53.8 microA h cm-2 and 63.1 microA h cm(-2), respectively at the same current density. The amorphous nanotubes show excellent capacity retention ability over 50 cycles. The cycled nanotubes show little change in morphology compared to the nanotubes before electrochemical cycling. All the TiO2 nanotubes demonstrate higher capacities than amorphous TiO2 compact layer reported in literature. The amorphous TiO2 nanotubes with a length of 1.9 microm exhibit a capacity five times higher than that of TiO2 compact layer even when the nanotube array is cycled at a current density 80 times higher than that for the compact layer. These results suggest that anodic TiO2 nanotube arrays are promising electrode materials for rechargeable Li-ion batteries.

  1. Virulence of Hymenoscyphus albidus and H. fraxineus on Fraxinus excelsior and F. pennsylvanica

    PubMed Central

    Kowalski, Tadeusz; Bilański, Piotr; Holdenrieder, Ottmar

    2015-01-01

    European ash (Fraxinus excelsior) is currently battling an onslaught of ash dieback, a disease emerging in the greater part of its native area, brought about by the introduction of the ascomycete Hymenoscyphus fraxineus (= Hymenoscyphus pseudoalbidus). The closely-related fungus Hymenoscyphus albidus, which is indigenous to Europe, is non-pathogenic when in contact with F. excelsior, but could pose a potential risk to exotic Fraxinus species. The North American green ash (Fraxinus pennsylvanica) is planted widely throughout Europe and regenerates naturally within this environment but little is known about the susceptibility of this species to ash dieback. We performed wound inoculations with both fungi (nine strains of H. fraxineus and three strains of H. albidus) on rachises and stems of F. excelsior and F. pennsylvanica under field conditions in Southern Poland. Necrosis formation was evaluated after two months on the rachises and after 12 months on the stems. After inoculation of H. albidus, only small lesions (of up to 1.3 cm in length) developed on the F. excelsior and F. pennsylvanica rachises, but with no significant distinction from the controls. Hymenoscyphus albidus did not cause necrotic lesions on the stems of either Fraxinus species. In contrast, H. fraxineus induced necroses on all inoculated rachises of both ash species with mean lengths of 8.4 cm (F. excelsior) and 1.9 cm (F. pennsylvanica). Necroses also developed on all of the inoculated F. excelsior stems (mean length 18.0 cm), whereas on F. pennsylvanica such lesions only occurred on about 5% of the stems (mean length 1.9 cm). The differences between strains were negligible. No necroses were observed on the control plants. Reisolations of H. albidus were only successful in around 8–11% of the cases, while H. fraxineus was reisolated from 50–70% of the inoculated organs showing necrotic lesions. None of the Hymenoscyphus species were isolated from the control plants. Our data confirm H. fraxineus’ high virulence with regards to F. excelsior and demonstrate a low virulence in relation to F. pennsylvanica under field conditions in Poland. Hymenoscyphus albidus did not express any perceivable pathogenicity on both host species. PMID:26517266

  2. Optimizing micropropagation of drought resistant Pyrus boissieriana Buhse.

    PubMed

    Zakavi, Maryam; Askari, Hossein; Irvani, Neda

    2016-10-01

    The present study concentrated on introducing a micropropagation protocol for a drought resistant genotype from Pyrus boissieriana , which is the second most naturally widespread pear species in Iran with proper physiological and medicinal properties. Proliferating microshoot cultures were obtained by placing nodal segments on MS medium supplemented with BAP and IBA or NAA. The highest number of shoots (27 shoots per explant) were obtained with 1.5 mg l -1 BAP and 0.05 mg l -1 IBA, but this combination did not produce shoots of desirable length (>1.7 cm). Combination of 1.75 mg l -1 BAP and 0.07 mg l -1 IBA was the best for the shoot multiplication in P. boissieriana with a sufficient number of shoot production (22.33 shoots per explant) and relatively more appropriate shoot length. The larger and greenish leaves were obtained when PG was added to the best multiplication treatment. Microshoot elongation was carried out in 1/2 and 1/4 MS medium containing 50-100 mg l -1 PG with different concentrations of IBA or NAA at intervals of 30-60 days. Significant increase in shoot length was detected after 45-60 days of culture in the presence of PG. The highest shoot length (8 cm) was recorded on 1/2 MS medium supplemented with 0.5 mg l -1 IBA and 100 mg l -1 PG. GA 3 negatively affected number and length of shoots and generally caused generation of red leaves. The highest percentage of root induction (100%) and root length (9 cm) were obtained on 1/6 strength MS medium supplemented with 0.005 mg l -1 IBA. All plantlets were hardened when transferred to ex vitro conditions through a period of 25-30 days. The results suggest axillary shoot proliferation of P. boissieriana could successfully be employed for propagation of candidate drought resistant seedling.

  3. Measurement of Two-Plasmon-Decay Dependence on Plasma Density Scale Length

    NASA Astrophysics Data System (ADS)

    Haberberger, D.

    2013-10-01

    An accurate understanding of the plasma scale-length (Lq) conditions near quarter-critical density is important in quantifying the hot electrons generated by the two-plasmon-decay (TPD) instability in long-scale-length plasmas. A novel target platform was developed to vary the density scale length and an innovative diagnostic was implemented to measure the density profiles above 1021 cm-3 where TPD is expected to have the largest growth. A series of experiments was performed using the four UV (351-nm) beams on OMEGA EP that varied the Lq by changing the radius of curvature of the target while maintaining a constant Iq/Tq. The fraction of laser energy converted to hot electrons (fhot) was observed to increase rapidly from 0.005% to 1% by increasing the plasma scale length from 130 μm to 300 μm, corresponding to target diameters of 0.4 mm to 8 mm. A new diagnostic was developed based on refractometry using angular spectral filters to overcome the large phase accumulation in standard interferometric techniques. The angular filter refractometer measures the refraction angles of a 10-ps, 263-nm probe laser after propagating through the plasma. An angular spectral filter is used in the Fourier plane of the probe beam, where the refractive angles of the rays are mapped to space. The edges of the filter are present in the image plane and represent contours of constant refraction angle. These contours are used to infer the phase of the probe beam, which are used to calculate the plasma density profile. In long-scale-length plasmas, the diagnostic currently measures plasma densities from ~1019 cm-3 to ~2 × 1021 cm-3. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944. In collaboration with D. H. Edgell, S. X. Hu, S. Ivancic, R. Boni, C. Dorrer, and D. H. Froula (Laboratory for Laser Energetics, U. of Rochester).

  4. Cervical Length in Patients at Risk for Placenta Accreta.

    PubMed

    Rac, Martha W F; McIntire, Donald D; Wells, C Edward; Moschos, Elysia; Twickler, Diane D

    2017-07-01

    To evaluate cervical length measurements in women with placenta accreta compared to women with a nonadherent low-lying placenta or placenta previa and evaluate this relationship in terms of vaginal bleeding, preterm labor, and preterm birth. We conducted a retrospective cohort study between 1997 and 2011 of gravidas with more than 1 prior cesarean delivery who had a transvaginal ultrasound examination between 24 and 34 weeks for a low-lying placenta or placenta previa. Cervical length was measured from archived images in accordance with national guidelines by a single investigator, who was blinded to outcomes and ultrasound reports. The diagnosis of placental accreta was based on histologic confirmation. For study purposes, preterm birth was defined as less than 36 weeks, and cervical lengths of 3 cm or less were considered short. Standard statistical analyses were used. A total of 125 patients met inclusion criteria. The cohort was divided into patients with (n = 43 [34%]) and without (n = 82 [66%]) placenta accreta and stratified by gestational age at the ultrasound examinations. Women with placenta accreta had shorter cervical length measurements during their 32- to 34-week ultrasound examinations (mean ± SD, 3.23 ± 0.98 versus 3.95 ± 1.0 cm; P < .01) and were more likely to have a short cervix of 3 cm or less (P = .001). However, these findings did not correlate with the degree of invasion (P = .3), or higher rates of vaginal bleeding and preterm labor (P = .19) resulting in preterm birth before 36 weeks (P = .64). Women with placenta accreta had shorter cervical lengths at 32 to 34 weeks than women with a nonadherent low-lying placenta or placenta previa, but this finding did not correlate with a higher risk of vaginal bleeding or preterm labor resulting in preterm birth before 36 weeks. © 2017 by the American Institute of Ultrasound in Medicine.

  5. Imaging of patent foramen ovale with 64-section multidetector CT.

    PubMed

    Saremi, Farhood; Channual, Stephanie; Raney, Aidan; Gurudevan, Swaminatha V; Narula, Jagat; Fowler, Steven; Abolhoda, Amir; Milliken, Jeffrey C

    2008-11-01

    To investigate the feasibility of 64-section multidetector computed tomography (CT) by using CT angiography (a) to demonstrate anatomic detail of the interatrial septum pertinent to the patent foramen ovale (PFO), and (b) to visually detect left-to-right PFO shunts and compare these findings in patients who also underwent transesophageal echocardiography (TEE). In this institutional review board-approved HIPAA-compliant study, electrocardiographically gated coronary CT angiograms in 264 patients (159 men, 105 women; mean age, 60 years) were reviewed for PFO morphologic features. The length and diameter of the opening of the PFO tunnel, presence of atrial septal aneurysm (ASA), and PFO shunts were evaluated. A left-to-right shunt was assigned a grade according to length of contrast agent jet (grade 1, 1 cm to 2 cm; grade 3, >2 cm). In addition, 23 patients who underwent both modalities were compared (Student t test and linear regression analysis). A difference with P < .05 was significant. A flap valve, seen in 101 (38.3%) patients, was patent at the entry into the right atrium (PFO) in 62 patients (61.4% of patients with flap valve, 23.5% of total patients). A left-to-right shunt was detected in 44 (16.7% of total) patients (grade 1, 61.4%; grade 2, 34.1%; grade 3, 4.5%). No shunt was seen in patients without a flap valve. Mean length of PFO tunnel was 7.1 mm in 44 patients with a shunt and 12.1 mm in 57 patients with a flap valve without a shunt (P < .0001). In patients with a tunnel length of 6 mm or shorter, 92.6% of the shunts were seen. ASA was seen in 11 (4.2%) patients; of these patients, a shunt was seen in seven (63.6%). In 23 patients who underwent CT angiography and TEE, both modalities showed a PFO shunt in seven. Multidetector CT provides detailed anatomic information about size, morphologic features, and shunt grade of the PFO. Shorter tunnel length and septal aneurysms are frequently associated with left-to-right shunts in patients with PFO. (c) RSNA, 2008.

  6. Prenatal Exposure to Organophosphorous Pesticides and Fetal Growth: Pooled Results from Four Longitudinal Birth Cohort Studies.

    PubMed

    Harley, Kim G; Engel, Stephanie M; Vedar, Michelle G; Eskenazi, Brenda; Whyatt, Robin M; Lanphear, Bruce P; Bradman, Asa; Rauh, Virginia A; Yolton, Kimberly; Hornung, Richard W; Wetmur, James G; Chen, Jia; Holland, Nina T; Barr, Dana Boyd; Perera, Frederica P; Wolff, Mary S

    2016-07-01

    Organophosphorous (OP) pesticides are associated with reduced fetal growth in animals, but human studies are inconsistent. We pooled data from four cohorts to examine associations of prenatal OP exposure with birth weight (n = 1,169), length (n = 1,152), and head circumference (n = 1,143). Data were from the CHAMACOS, HOME, Columbia, and Mount Sinai birth cohorts. Concentrations of three diethyl phosphate (ΣDEP) and three dimethyl phosphate (ΣDMP) metabolites of OP pesticides [summed to six dialkyl phosphates (ΣDAPs)] were measured in maternal urine. Linear regression and mixed-effects models were used to examine associations with birth outcomes. We found no significant associations of ΣDEP, ΣDMP, or ΣDAPs with birth weight, length, or head circumference overall. However, among non-Hispanic black women, increasing urinary ΣDAP and ΣDMP concentrations were associated with decreased birth length (β = -0.4 cm; 95% CI: -0.9, 0.0 and β = -0.4 cm; 95% CI: -0.8, 0.0, respectively, for each 10-fold increase in metabolite concentration). Among infants with the PON1192RR genotype, ΣDAP and ΣDMP were negatively associated with length (β = -0.4 cm; 95% CI: -0.9, 0.0 and β = -0.5 cm; 95% CI: -0.9, -0.1). This study confirms previously reported associations of prenatal OP exposure among black women with decreased infant size at birth, but finds no evidence of smaller birth weight, length, or head circumference among whites or Hispanics. Contrary to our hypothesis, we found stronger inverse associations of DAPs and birth outcome in infants with the less susceptible PON1192RR genotype. The large pooled data set facilitated exploration of interactions by race/ethnicity and PON1 genotype, but was limited by differences in study populations. Harley KG, Engel SM, Vedar MG, Eskenazi B, Whyatt RM, Lanphear BP, Bradman A, Rauh VA, Yolton K, Hornung RW, Wetmur JG, Chen J, Holland NT, Barr DB, Perera FP, Wolff MS. 2016. Prenatal exposure to organophosphorous pesticides and fetal growth: pooled results from four longitudinal birth cohort studies. Environ Health Perspect 124:1084-1092; http://dx.doi.org/10.1289/ehp.1409362.

  7. MO-G-17A-02: Computer Simulation Studies for On-Board Functional and Molecular Imaging of the Prostate Using a Robotic Multi-Pinhole SPECT System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, L; Duke University Medical Center, Durham, NC; Fudan University Shanghai Cancer Center, Shanghai

    Purpose: To investigate prostate imaging onboard radiation therapy machines using a novel robotic, 49-pinhole Single Photon Emission Computed Tomography (SPECT) system. Methods: Computer-simulation studies were performed for region-of-interest (ROI) imaging using a 49-pinhole SPECT collimator and for broad cross-section imaging using a parallel-hole SPECT collimator. A male XCAT phantom was computersimulated in supine position with one 12mm-diameter tumor added in the prostate. A treatment couch was added to the phantom. Four-minute detector trajectories for imaging a 7cm-diameter-sphere ROI encompassing the tumor were investigated with different parameters, including pinhole focal length, pinhole diameter and trajectory starting angle. Pseudo-random Poisson noise wasmore » included in the simulated projection data, and SPECT images were reconstructed by OSEM with 4 subsets and up to 10 iterations. Images were evaluated by visual inspection, profiles, and Root-Mean- Square-Error (RMSE). Results: The tumor was well visualized above background by the 49-pinhole SPECT system with different pinhole parameters while it was not visible with parallel-hole SPECT imaging. Minimum RMSEs were 0.30 for 49-pinhole imaging and 0.41 for parallelhole imaging. For parallel-hole imaging, the detector trajectory from rightto- left yielded slightly lower RMSEs than that from posterior to anterior. For 49-pinhole imaging, near-minimum RMSEs were maintained over a broader range of OSEM iterations with a 5mm pinhole diameter and 21cm focal length versus a 2mm diameter pinhole and 18cm focal length. The detector with 21cm pinhole focal length had the shortest rotation radius averaged over the trajectory. Conclusion: On-board functional and molecular prostate imaging may be feasible in 4-minute scan times by robotic SPECT. A 49-pinhole SPECT system could improve such imaging as compared to broadcross-section parallel-hole collimated SPECT imaging. Multi-pinhole imaging can be improved by considering pinhole focal length, pinhole diameter, and trajectory starting angle. The project is supported by the NIH grant 5R21-CA156390.« less

  8. [Diet, selectivity and trophic overlap between the sizes of silverside Menidia humboldtiana (Atheriniformes: Atherinopsidae) in the reservoir Tiacaque, Mexico].

    PubMed

    Sánchez, Regina; Ochoa, Abigahil; Mendoza, Angélica

    2013-06-01

    D Menidia humboldtiana, a native species of Mexico, is a common inhabitant of local reservoirs. It represents a highly appreciated fish of economic importance in the central part of the country because of its delicate flavor. Trophic behavior of this species is important to understand the relationships with other fish species in reservoirs. With the aim to study this specific topic, the trophic spectrum, selectivity coefficient and overlap, were determined among different sizes of the Silverside M humboldtiana. For this, both zooplankton and fish samples were taken during four different seasons of 1995. Zooplankton samples were taken through a mesh (125 micron), and all organisms were identified to generic level. Fish were captured and grouped into standard length intervals per season, and the stomach contents were obtained and analyzed. Trophic interactions included the stomach contents analysis (Laevastu method), the coefficient of selection (Chesson) and the trophic overlap (Morisita index modified by Horn) between sizes. A total of 14 zooplankton genera were identified, of which Bosmina was the most abundant (29 625 ind./10 L) followed by Cyclops (9496 ind./10 L), during the spring. Small size fishes (1-4.9cm) consumed high percentages of Cyclops in the spring (61.24%) and winter (69.82%). Ceriodaphnia was consumed by fish sizes of 3-10.9cm (72.41%) and 13-14.9cm (95.5%) during the summer; while in autumn, small sizes (1-4.9cm) ingested Mastigodiaptomus and Ceriodaphnia; Daphnia and Bosmina were consumed by fishes of 5-8.9cm and the biggest sizes (9-14.9 cm) feed on Ceriodaphnia. M. humboldtiana makes a selective predation by the genera Ceriodaphnia, Daphnia, Mastigodiaptomus, Bosmina and Cyclops, depending on the size length interval. The trophic overlap was very marked among all sizes on spring, autumn and winter, unlike in summer fish of 1-2.9 and 11-12.9 cm did not show overlap with other length intervals. M humboldtiana is a zooplanktivore species, which performs a selective predation and a marked trophic overlap between the different fish sizes.

  9. [Effects of light intensity on Quercus liaotungensis seed germination and seedling growth].

    PubMed

    Yan, Xing-fu; Wang, Jian-li; Zhou, Li-biao

    2011-07-01

    This paper studied the effects of different shading (55.4%, 18.9%, 5.5%, 2.2%, 0.5% , and 0.3% natural sunlight) on the seed germination and seedling growth of Quercus liaotungensis. The seed germination rate and germination index were the highest (72.5% and 0.22, respectively) at 55.4% natural sunlight, declined with decreasing light intensity, and were the lowest (42.5% and 0.11, respectively) at 0.3% natural sunlight. Strong light had definite delaying effect on the germination. The index of germination vigor increased with decreasing light intensity, being the maximum at 0.5% natural sunlight. The delay of seed germination under strong light could be the selective tradeoff on varied seed fates. Strong light benefited the basal stem diameter and root system growth and dry mass accumulation of Q. liaotunensis seedling, but resulted in the minimum seedlings height (6.06 cm). Greater morphological plasticity was observed for the seedlings under different shading, which lent support to the higher adaptability of the seedlings to light environment. For example, the specific leaf area, specific shoot length, specific root length, and chlorophyll b and total chlorophyll contents were the maximum at 0.5% natural sunlight, being 142.57 cm2 x g(-1), 156.86 cm x g(-1), 271.87 cm x g(-1), 0.07 g x cm(-2), and 0.24 g x cm(-2), respectively, and the minimum at 55.4% natural sunlight, being 44.89 cm2 x g(-1), 52.84 cm x g(-1), 101.98 cm x g(-1), 0.04 g x cm(-2), and 0.15 g x cm(-2), respectively. The variation of the root/shoot ratio of Q. liaotungensis seedlings under different shading could be the effects of the combination of light intensity and water availability.

  10. How Big is Too Big? The Girth of Bestselling Insertive Sex Toys to Guide Maximal Neophallus Dimensions.

    PubMed

    Isaacson, Dylan; Aghili, Roxana; Wongwittavas, Non; Garcia, Maurice

    2017-11-01

    In our practice we have encountered 4 female-to-male transgender patients seeking neophallus revision surgery for girth precluding penetrative vaginal or anal intercourse. Despite this, there is little evidence available to guide transitioning patients in neophallus sizing. In this work we examined the dimensions of bestselling realistic dildos, presuming that the most popular dimensions would reflect population preferences for penetrative toys and phalluses. To determine a maximal upper limit for girth compatible with penetrative intercourse based on measurements of bestselling realistic dildos and published erect penile dimensions. We collected measurements for "realistic dildos" designated as bestsellers for the top 5 Alexa.com-rated online adult retailers in the United States and for Amazon.com. We compared these with measurements of dildos available at Good Vibrations in San Francisco and with studies of erect natal dimensions. We compared all data with measurements of 4 index patients whose neophallus girth prevented penetrative intercourse. Length and circumference of overall bestselling and largest bestselling realistic dildos as reported on top websites and measured by investigators. The average insertive length of the compiled dildos (16.7 ± 1.6 cm) was 1 SD longer than natal functional erect penile length as reported in the literature (15.7 ± 2.6 cm); however, their average circumference (12.7 ± 0.8 cm) mirrored natal erect penile girth (12.3 ± 1.3). The average girth of vendors' top 3 largest-girth dildos was 15.1 ± 0.9 cm, 2 SD wider than natal erect penile girth. Index patients had an average length of 16.3 ± 3.2 cm and an average girth of 17.6 ± 1.3 cm. Index patient girth was 4 to 5 SD wider than the average natal erect girth. Based on our data, we suggest that a surgically created neophallus should have a girth no wider than 15.1 cm after implantation of an inflatable penile prosthesis. This corresponds to 2 SD wider than the average natal man's erect girth. Strengths include in-person measurements of patients whose girth prevented penetrative intercourse, the large number of dildos assessed, and correlations with in-person measurements. Limitations include the inability to account for the pliability of different materials, whether dildos were used for vaginal and/or anal insertion, the limited sample of 4 transmen for in-person measurement, and the absence of implanted inflatable penile prostheses in index neophalluses. Neophallus girth wider than 15.1 cm could lead to difficulty in penetrative intercourse for many individuals. A conservative recommendation for neophallus girth is 13 to 14 cm, or 0.5 to 1.5 SD wider than natal erect penile girth. Isaacson D, Aghili R, Wongwittavas N, Garcia M. How Big is Too Big? The Girth of Bestselling Insertive Sex Toys to Guide Maximal Neophallus Dimensions. J Sex Med 2017;14:1455-1461. Copyright © 2017. Published by Elsevier Inc.

  11. The Geoid Slope Validation Survey 2014 and GRAV-D airborne gravity enhanced geoid comparison results in Iowa

    NASA Astrophysics Data System (ADS)

    Wang, Y. M.; Becker, C.; Mader, G.; Martin, D.; Li, X.; Jiang, T.; Breidenbach, S.; Geoghegan, C.; Winester, D.; Guillaume, S.; Bürki, B.

    2017-10-01

    Three Geoid Slope Validation Surveys were planned by the National Geodetic Survey for validating geoid improvement gained by incorporating airborne gravity data collected by the "Gravity for the Redefinition of the American Vertical Datum" (GRAV-D) project in flat, medium and rough topographic areas, respectively. The first survey GSVS11 over a flat topographic area in Texas confirmed that a 1-cm differential accuracy geoid over baseline lengths between 0.4 and 320 km is achievable with GRAV-D data included (Smith et al. in J Geod 87:885-907, 2013). The second survey, Geoid Slope Validation Survey 2014 (GSVS14) took place in Iowa in an area with moderate topography but significant gravity variation. Two sets of geoidal heights were computed from GPS/leveling data and observed astrogeodetic deflections of the vertical at 204 GSVS14 official marks. They agree with each other at a {± }1.2 cm level, which attests to the high quality of the GSVS14 data. In total, four geoid models were computed. Three models combined the GOCO03/5S satellite gravity model with terrestrial and GRAV-D gravity with different strategies. The fourth model, called xGEOID15A, had no airborne gravity data and served as the benchmark to quantify the contribution of GRAV-D to the geoid improvement. The comparisons show that each model agrees with the GPS/leveling geoid height by 1.5 cm in mark-by-mark comparisons. In differential comparisons, all geoid models have a predicted accuracy of 1-2 cm at baseline lengths from 1.6 to 247 km. The contribution of GRAV-D is not apparent due to a 9-cm slope in the western 50-km section of the traverse for all gravimetric geoid models, and it was determined that the slopes have been caused by a 5 mGal bias in the terrestrial gravity data. If that western 50-km section of the testing line is excluded in the comparisons, then the improvement with GRAV-D is clearly evident. In that case, 1-cm differential accuracy on baselines of any length is achieved with the GRAV-D-enhanced geoid models and exhibits a clear improvement over the geoid models without GRAV-D data. GSVS14 confirmed that the geoid differential accuracies are in the 1-2 cm range at various baseline lengths. The accuracy increases to 1 cm with GRAV-D gravity when the west 50 km line is not included. The data collected by the surveys have high accuracy and have the potential to be used for validation of other geodetic techniques, e.g., the chronometric leveling. To reach the 1-cm height differences of the GSVS data, a clock with frequency accuracy of 10^{-18} is required. Using the GSVS data, the accuracy of ellipsoidal height differences can also be estimated.

  12. Influence of Gender and Age on Upper-Airway Length During Development

    PubMed Central

    Ronen, Ohad; Malhotra, Atul; Pillar, Giora

    2008-01-01

    OBJECTIVE Obstructive sleep apnea has a strong male predominance in adults but not in children. The collapsible portion of the upper airway is longer in adult men than in women (a property that may increase vulnerability to collapse during sleep). We sought to test the hypothesis that in prepubertal children, pharyngeal airway length is equal between genders, but after puberty boys have a longer upper airway than girls, thus potentially contributing to this change in apnea propensity. METHODS Sixty-nine healthy boys and girls who had undergone computed tomography scans of their neck for other reasons were selected from the computed tomography archives of Rambam and Carmel hospitals. The airway length was measured in the midsagittal plane and defined as the length between the lower part of the posterior hard palate and the upper limit of the hyoid bone. Airway length and normalized airway length/body height were compared between the genders in prepubertal (4- to 10-year-old) and postpubertal (14- to 19-year-old) children. RESULTS In prepubertal children, airway length was similar between boys and girls (43.2 ± 5.9 vs 46.8 ± 7.7 mm, respectively). When normalized to body height, airway length/body height was significantly shorter in prepubertal boys than in girls (0.35 ± 0.03 vs 0.38 ± 0.04 mm/cm). In contrast, postpubertal boys had longer upper airways (66.5 ± 9.2 vs 52.2 ± 7.0 mm) and normalized airway length/body height (0.38 ± 0.05 vs 0.33 ± 0.05 mm/cm) than girls. CONCLUSIONS Although boys have equal or shorter airway length compared with girls among prepubertal children, after puberty, airway length and airway length normalized for body height are significantly greater in boys than in girls. These data suggest that important anatomic changes at puberty occur in a gender-specific manner, which may be important in explaining the male predisposition to pharyngeal collapse in adults. PMID:17908723

  13. Functional magnetic stimulation of the abdominal muscles in humans.

    PubMed

    Polkey, M I; Luo, Y; Guleria, R; Hamnegård, C H; Green, M; Moxham, J

    1999-08-01

    Functional magnetic stimulation (FMS) of the thoracic nerve roots to simulate cough has been suggested as a treatment approach in patients unable to voluntarily activate the abdominal muscles. However, factors that could influence the efficacy of FMS in clinical use have not been evaluated. In the present investigation we studied train length, posture, and frequency to determine the optimal stimulation protocol. We also evaluated the use of a valve at the mouth to enhance glottic function and investigated whether lung volume at the time of stimulation would influence the tension generated by the abdominal muscles. Studies were performed using a Magstim rapid stimulator augmented by four booster packs in nine healthy subjects; we measured the change in gastric (DeltaPga(FMS)), esophageal (DeltaPes(FMS)), and mouth pressure and expiratory flow. With our apparatus pressure generation was maximized by having a train length of at least 300 ms and a frequency of 25 Hz. Posture and valve use were not important determinants of DeltaPga(FMS) or DeltaPes(FMS). Lung volume exerted only a minor influence on DeltaPga(FMS), but the ratio DeltaPes(FMS):DeltaPga(FMS) was increased at TLC compared with FRC. Expiratory flow was increased by adopting a seated posture and using an occlusion valve with an opening threshold close to the maximum DeltaPes(FMS) generated by the stimulus train; however, expiratory flow was susceptible to interference from glottic incoordination. Representative results (with train length 600 ms, 25 Hz, and 100% power, seated) were mean DeltaPga(FMS), 166 cm H(2)O; mean DeltaPes(FMS), 108 cm H(2)O; and mean expiratory flow, 311 L/min. We confirm that FMS of the abdominal muscles can generate a substantial positive intra-abdominal and intrathoracic pressure and, consequently, expiratory flow in normal subjects.

  14. Near Work Related Parameters and Myopia in Chinese Children: the Anyang Childhood Eye Study

    PubMed Central

    Li, Shi-Ming; Li, Si-Yuan; Kang, Meng-Tian; Zhou, Yuehua; Liu, Luo-Ru; Li, He; Wang, Yi-Peng; Zhan, Si-Yan; Gopinath, Bamini; Mitchell, Paul; Wang, Ningli

    2015-01-01

    Purpose To examine the associations of near work related parameters with spherical equivalent refraction and axial length in Chinese children. Methods A total of 1770 grade 7 students with mean age of 12.7 years were examined with cycloplegic autorefraction and axial length. Questions were asked regarding time spent in near work and outdoors per day, and near work related parameters. Results Multivariate models revealed the following associations with greater odds of myopia: continuous reading (> 45min), odds ratio [OR], 1.4; 95% confidence interval [CI], 1.1-1.8; close television viewing distance (≤ 3m), OR, 1.7; 95% CI, 1.2-2.3; head tilt when writing, OR, 1.3; 95% CI, 1.1-1.7, and desk lighting using fluorescent vs. incandescent lamp, OR, 1.5; 95% CI, 1.2-2.0. These factors, together with close reading distance and close nib-to-fingertip distance were significantly associated with greater myopia (P<0.01). Among near work activities, only reading more books for pleasure was significantly associated with greater myopia (P=0.03). Television viewing distance (≤ 3 m), fluorescent desk light, close reading distance (≤20 cm) and close nib-to-fingertip distance (≤ 2 cm) were significantly associated with longer axial length (P<0.01). Reading distance, desk light, and reading books for pleasure had significant interaction effects with parental myopia. Conclusions Continuous reading, close distances of reading, television viewing and nib-to-fingertip, head tilt when writing, reading more books for pleasure and use of fluorescent desk light were significantly associated with myopia in 12-year-old Chinese children, which indicates that visual behaviors and environments may be important factors mediating the effects of near work on myopia. PMID:26244865

  15. The correlation between structural properties, geometrical features, and photoactivity of freestanding TiO2 nanotubes in comparative degradation of 2,4-dichlorophenol and methylene blue

    NASA Astrophysics Data System (ADS)

    Vahabzadeh Pasikhani, Javad; Gilani, Neda; Ebrahimian Pirbazari, Azadeh

    2018-02-01

    Freestanding TiO2 nanotubes (FSNTs) with various physical dimensions were fabricated by two-step anodization process with different voltages and anodization times. The detachment method employed in this study involved voltage reduction at the end of the second step and ultrasonic chemical treatment. The results demonstrated that this detachment method is a beneficial technique to create thin open-mouthed and closed-end FSNTs (with lengths of 6-14 μm). Moreover, the influences of anodization conditions on photocatalytic activity, structural properties and geometrical features of FSNTs in comparative degradation of two non-colored (2,4-dichlorophenol) and colored (methylene blue) pollutants were investigated. Findings revealed that the quantity of the photocatalyst utilized is an effective parameter and using the optimum weight (10 mg/100 ml of 2,4-dichlorophenol) could increase the efficiency of the process up to 21%. Further, the results demonstrated that if equal optimum weights of FSNTs are chosen, decreases in voltage and anodization time significantly influence the structural properties, geometrical features, and photodegradation efficiency. The enhancement achieved in the degradation of both 2,4-dichlorophenol and methylene blue using the nanotubes with the shortest diameter (54 nm) and length (6.5 μm), which possess the lowest porosity (0.5) and also the highest surface area (0.53 m2 g-1), nanotubes’ density (19 cm2 cm-2) and wall thickness to length ratio (2). In addition, the results obtained indicated that the degradation reactions follow first-order kinetics in the degradation of the both pollutants. The apparent degradation rate constant of methylene blue was approximately 1.2 times greater than of the 2,4-dichlorophenol due to the negative charge of the nanotubes’ surface and electrostatic adsorptions.

  16. Slow light Mach-Zehnder interferometer as label-free biosensor with scalable sensitivity

    DOE PAGES

    Qin, Kun; Hu, Shuren; Retterer, Scott T.; ...

    2016-02-05

    Our design, fabrication, and characterization of a label-free Mach–Zehnder interferometer (MZI) optical biosensor that incorporates a highly dispersive one-dimensional (1D) photonic crystal in one arm are presented. The sensitivity of this slow light MZI-based sensor scales with the length of the slow light photonic crystal region. The numerically simulated sensitivity of a MZI sensor with a 16 μm long slow light region is 115,000 rad/RIU-cm, which is sevenfold higher than traditional MZI biosensors with millimeter-length sensing regions. Moreover, the experimental bulk refractive index detection sensitivity of 84,000 rad/RIU-cm is realized and nucleic acid detection is also demonstrated.

  17. Effect of high-pitch dual-source CT to compensate motion artifacts: a phantom study.

    PubMed

    Farshad-Amacker, Nadja A; Alkadhi, Hatem; Leschka, Sebastian; Frauenfelder, Thomas

    2013-10-01

    To evaluate the potential of high-pitch, dual-source computed tomography (DSCT) for compensation of motion artifacts. Motion artifacts were created using a moving chest/cardiac phantom with integrated stents at different velocities (from 0 to 4-6 cm/s) parallel (z direction), transverse (x direction), and diagonal (x and z direction combined) to the scanning direction using standard-pitch (SP) (pitch = 1) and high-pitch (HP) (pitch = 3.2) 128-detector DSCT (Siemens, Healthcare, Forchheim, Germany). The scanning parameters were (SP/HP): tube voltage, 120 kV/120 kV; effective tube current time product, 300 mAs/500 mAs; and a pitch of 1/3.2. Motion artifacts were analyzed in terms of subjective image quality and object distortion. Image quality was rated by two blinded, independent observers using a 4-point scoring system (1, excellent; 2, good with minor object distortion or blurring; 3, diagnostically partially not acceptable; and 4, diagnostically not acceptable image quality). Object distortion was assessed by the measured changes of the object's outer diameter (x) and length (z) and a corresponding calculated distortion vector (d) (d = √(x(2) + z(2))). The interobserver agreement was excellent (k = 0.91). Image quality using SP was diagnostically not acceptable with any motion in x direction (scores 3 and 4), in contrast to HP DSCT where it remained diagnostic up to 2 cm/s (scores 1 and 2). For motion in the z direction only, image quality remained diagnostic for SP and HP DSCT (scores 1 and 2). Changes of the object's diameter (x), length (z), and distortion vectors (d) were significantly greater with SP (overall: x = 1.9 cm ± 1.7 cm, z = 0.6 cm ± 0.8 cm, and d = 1.4 cm ± 1.5 cm) compared to HP DSCT (overall: x = 0.1 cm ± 0.1 cm, z = 0.0 cm ± 0.1 cm, and d = 0.1 cm ± 0.1 cm; each P < .05). High-pitch DSCT significantly decreases motion artifacts in various directions and improves image quality. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  18. Efficacy of three insecticides applied to bark to control Agrilus planipennis (Coleoptera: Buprestidae)

    Treesearch

    Toby R. Petrice; Robert A. Haack

    2006-01-01

    Emerald ash borer (EAB), Agrilus planipennis Fairmaire (Coleoptera: Buprestidae), is a serious exotic pest of ash (Fraxinus) trees in North America. In 2003 and 2004, we tested the efficacy of different insecticides sprayed on the bark of cut ash logs for killing emerging EAB adults. Logs (means: length = 30 cm; diam. = 16 cm) were...

  19. Precision Atomic Beam Spectroscopy Using Stabilized Lasers.

    DTIC Science & Technology

    1985-06-30

    spacer (a Zerodur rod 15 cm dia. by 30 cm length) under ir I MN, M A 9 differentials of its own weight. A powerful tilt stabilization concept has been...1120-2523 (1936). 3504. Jo L. Hell, No Len -Sheng and G. Kramer,’Prinuiples of *ptical phase lock ng: :ith eppr catien to internal mirror Ne-o

  20. 50 CFR 32.28 - Florida.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... limit is five black bass per person, per day, where only one bass may be over 14 inches (35 cm) in... shot no larger than #4 birdshot when hunting. The refuge retains the discretion to allow the use of a... one or more antlers at least 5 inches (12.5 cm) in length visible above the hairline, and feral hog...

  1. 50 CFR 32.28 - Florida.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... limit is five black bass per person, per day, where only one bass may be over 14 inches (35 cm) in... shot no larger than #4 birdshot when hunting. The refuge retains the discretion to allow the use of a... one or more antlers at least 5 inches (12.5 cm) in length visible above the hairline, and feral hog...

  2. Conservation implications of spur length variation in long-spur columbines (Aquilegia longissima)

    Treesearch

    Christopher J. Stubben; Brook G. Milligan

    2007-01-01

    Populations of long-spur columbine (Aquilegia longissima) with spurs 10-16 cm long are known only from a few populations in Texas, a historical collection near Baboquivari Peak, Arizona, and scattered populations in Coahuila, Chihuahua, and Nuevo Leon, Mexico. Populations of yellow columbine with spurs 7-10 cm long are also found in Arizona, Texas,...

  3. A Novel Method for Measurement and Characterization of Soil Macroporosity

    Treesearch

    Christopher Barton; Tasos Karathanasis

    2002-01-01

    Quantitative macropore characterizations were performed in large zero-tension soil lysimeters of a Maury silt loam (fine, mixed, mesic Typic Paleudalf) and a Loradale silt loam (fine, silty, mixed, mesic Typic Axgiudoll) soil in an effort to assess potential colloid transport. Steel pipe sections (50 cm diameter X 100 cm length) were hydraulically driven into the soil...

  4. Strategies for obstacle avoidance during walking in the cat.

    PubMed

    Chu, Kevin M I; Seto, Sandy H; Beloozerova, Irina N; Marlinski, Vladimir

    2017-08-01

    Avoiding obstacles is essential for successful navigation through complex environments. This study aimed to clarify what strategies are used by a typical quadruped, the cat, to avoid obstacles during walking. Four cats walked along a corridor 2.5 m long and 25 or 15 cm wide. Obstacles, small round objects 2.5 cm in diameter and 1 cm in height, were placed on the floor in various locations. Movements of the paw were recorded with a motion capture and analysis system (Visualeyez, PTI). During walking in the wide corridor, cats' preferred strategy for avoiding a single obstacle was circumvention, during which the stride direction changed while stride duration and swing-to-stride duration ratio were preserved. Another strategy, stepping over the obstacle, was used during walking in the narrow corridor, when lateral deviations of walking trajectory were restricted. Stepping over the obstacle involved changes in two consecutive strides. The stride preceding the obstacle was shortened, and swing-to-stride ratio was reduced. The obstacle was negotiated in the next stride of increased height and normal duration and swing-to-stride ratio. During walking on a surface with multiple obstacles, both strategies were used. To avoid contact with the obstacle, cats placed the paw away from the object at a distance roughly equal to the diameter of the paw. During obstacle avoidance cats prefer to alter muscle activities without altering the locomotor rhythm. We hypothesize that a choice of the strategy for obstacle avoidance is determined by minimizing the complexity of neuro-motor processes required to achieve the behavioral goal. NEW & NOTEWORTHY In a study of feline locomotor behavior we found that the preferred strategy to avoid a small obstacle is circumvention. During circumvention, stride direction changes but length and temporal structure are preserved. Another strategy, stepping over the obstacle, is used in narrow walkways. During overstepping, two strides adjust. A stride preceding the obstacle decreases in length and duration. The following stride negotiating the obstacle increases in height while retaining normal temporal structure and nearly normal length. Copyright © 2017 the American Physiological Society.

  5. Optimizing Soft Tissue Management and Spacer Design in Segmental Bone Defects

    DTIC Science & Technology

    2016-12-01

    proximal and distal bone segments. 3. Debride 10 grams of tibialis anterior and gastrocnemius muscles. 4. Place an interlocking intramedullary nail ...using a custom spacer to maintain 5-cm defect length. 5. Place a pre-molded 5 cm long x 2 cm diameter PMMA spacer around the nail in the defect. 6...tibia. 3. Open the IM surrounding the PMMA spacer using a “bomb bay door opening”. 4. Remove the spacer without damaging the membrane or nail . 5

  6. Thermodynamic, Transport and Chemical Properties of Reference JP-8

    DTIC Science & Technology

    2006-06-01

    external diameter, 0.18 cm internal diameter) that are sealed on one end with a stainless steel plug welded by a clean tungsten-inert-gas ( TIG ) 15...tubing with an internal diameter of 0.02 cm, also TIG welded to the cell. Each cell and valve is capable of withstanding a pressure in excess of 105... process . Each cell is connected to a high-pressure high-temperature valve at the other end with a short length of 0.16 cm diameter 316 stainless steel

  7. Variability of 137Cs inventory at a reference site in west-central Iran.

    PubMed

    Bazshoushtari, Nasim; Ayoubi, Shamsollah; Abdi, Mohammad Reza; Mohammadi, Mohammad

    2016-12-01

    137 Cs technique has been widely used for the evaluation rates and patterns of soil erosion and deposition. This technique requires an accurate estimate of the values of 137 Cs inventory at the reference site. This study was conducted to evaluate the variability of the inventory of 137 Cs regarding to the sampling program including sample size, distance and sampling method at a reference site located in vicinity of Fereydan district in Isfahan province, west-central Iran. Two 3 × 8 grids were established comprising large grid (35 m length and 8 m width), and small grid (24 m length and 6 m width). At each grid intersection two soil samples were collected from 0 to 15 cm and 15-30 cm depths, totally 96 soil samples from 48 sampling points. Coefficients of variation for 137 Cs inventory in the soil samples was relatively low (CV = 15%), and the sampling distance and methods used did not significantly affect the 137 Cs inventories across the studied reference site. To obtain a satisfactory estimate of the mean 137 Cs activity in the reference sites, particularly those located in the semiarid regions, it is recommended to collect at least four samples along in a grid pattern 3 m apart. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. 50 CFR 648.72 - Minimum surf clam size.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Atlantic Surf Clam and Ocean Quahog Fisheries § 648.72 Minimum surf clam size. (a) Minimum length. The minimum length for surf clams is 4.75 inches (12.065 cm). (b) Determination of compliance. No more than 50... 50 Wildlife and Fisheries 8 2010-10-01 2010-10-01 false Minimum surf clam size. 648.72 Section 648...

  9. Components of height and blood pressure in childhood

    PubMed Central

    Regnault, Nolwenn; Kleinman, Ken P; Rifas-Shiman, Sheryl L; Langenberg, Claudia; Lipshultz, Steven E; Gillman, Matthew W

    2014-01-01

    Background In children being taller is associated with higher blood pressure (BP), but few studies have divided height into its components: trunk and leg length. We examined the associations of total height, trunk length and leg length with systolic BP (SBP), diastolic BP (DBP) and pulse pressure (PP) at early childhood and mid-childhood visits, as well as change between the two visits. Methods We obtained five measures of SBP and DBP at the early childhood visit (N = 1153, follow-up rate = 54%) and at the mid-childhood visit (N = 1086, follow-up rate = 51%) respectively, in Project Viva, a US cohort study. We measured total height and sitting height (a measure of trunk length that includes head and neck) and calculated leg length as the difference between the two. Using mixed models, we adjusted the cross-sectional analyses for leg length when trunk length was the exposure of interest, and vice versa. We also adjusted for maternal race/ethnicity, child age, sex, overall adiposity and BP measurement conditions. Results At the mid-childhood visit, total height was positively associated with SBP [0.34 (0.24; 0.45) mmHg/cm] but not with DBP [0.07 (−0.003; 0.15)]. In models examining trunk and leg length separately, each was positively associated with SBP [0.72 (0.52; 0.92) and 0.33 (0.16; 0.49) respectively]. In a fully adjusted model with both leg and trunk length, only trunk length remained associated with BP. For a given leg length, a 1-cm increment in trunk length was associated with a 0.63-mmHg (0.42; 0.83) higher SBP and a 0.17-mmHg (0.02; 0.31) higher DBP. For a given trunk length, however, the associations of leg length with SBP [0.13 (−0.03; 0.30)] and with DBP [0.002 (−0.11; 0.12)] were null. These patterns were similar at the early childhood visit. Conclusions Children with greater trunk lengths have higher BPs, perhaps because of the additional pressure needed to overcome gravity to perfuse the brain. PMID:24413933

  10. Association of Body Length with Ocular Parameters in Mice

    PubMed Central

    Chakraborty, Ranjay; Park, Han na; Tan, Christopher C.; Weiss, Paul; Prunt, Megan C.; Pardue, Machelle T.

    2017-01-01

    Purpose To determine the association between changes in body length with ocular refraction, corneal radii, axial length, and lens thickness in two different mouse strains. Methods Body length, ocular refraction, corneal radii, axial length, and lens thickness were measured for two inbred mouse strains: 129S1/SvJ (n=7) and C57BL/6J (n=10) from 4 to 12 weeks of age. Body length, from tip of nose to base of tail was obtained using a digital camera. Biometric parameters, corneal radii and refractions were measured using spectral-domain optical coherence tomography, automated keratometry and infrared photorefraction, respectively. A mixed model ANOVA was performed to examine the changes in ocular parameters as a function of body length and strain in mice controlling for age, gender and weight over time. Results C57BL/6J mice had significantly longer body length (average body length at 10 weeks, 8.60 ± 0.06 cm) compared 129S1/SvJ mice (8.31 ± 0.05 cm) during development (p<0.001). C57BL/6J mice had significantly hyperopic refractions compared to 129S1/SvJ mice across age (mean refraction at 10 weeks, 129S1/SvJ: +0.99 ± 0.44 D versus C57BL/6J: +6.24 ± 0.38 D, p<0.001). Corneal radius of curvature, axial length and lens thickness (except 10 weeks lens thickness) were similar between the two strains throughout the measurement. In the mixed model ANOVA, changes in body length showed an independent and significant association with the changes in refraction (p=0.002) and corneal radii (p=0.016) for each mouse strain. No significant association was found between the changes in axial length (p=0.925) or lens thickness (p=0.973) as a function of body length and strain. Conclusions Changes in body length are significantly associated with the changes in ocular refraction and corneal radii in different mouse strains. Future studies are needed to determine if the association between body length and ocular refraction are related to changes in corneal curvature in mice. PMID:28005683

  11. Neonatal outcomes following exposure in utero to fallout from Chernobyl.

    PubMed

    Hatch, Maureen; Little, Mark P; Brenner, Alina V; Cahoon, Elizabeth K; Tereshchenko, Valery; Chaikovska, Ludmyla; Pasteur, Igor; Likhtarov, Ilya; Bouville, Andre; Shpak, Victor; Bolshova, Olena; Zamotayeva, Galyna; Grantz, Katherine; Sun, Liping; Mabuchi, Kiyohiko; Albert, Paul; Tronko, Mykola

    2017-12-01

    Iodine 131 (I-131), the principal component of nuclear fallout from the Chernobyl accident, concentrates in the thyroid gland and may pose risks to fetal development. To evaluate this, neonatal outcomes following the accident in April of 1986 were investigated in a cohort of 2582 in utero-exposed individuals from northern Ukraine for whom estimates of fetal thyroid I-131 dose were available. We carried out a retrospective review of cohort members' prenatal, delivery and newborn records. The relationships of dose with neonatal anthropometrics and gestational length were modeled via linear regression with adjustment for potentially confounding variables. We found similar, statistically significant dose-dependent reductions in both head circumference (-1.0 cm/Gy, P = 0.005) and chest circumference (-0.9 cm/Gy, P = 0.023), as well as a similar but non-significant reduction in neonatal length (-0.6 cm/Gy, P = 0.169). Gestational length was significantly increased with increasing fetal dose (0.5 wks/Gy, P = 0.007). There was no significant (P > 0.1) effect of fetal dose on birth weight. The observed associations of radioiodine exposure with decreased head and chest circumference are consistent with those observed in the Japanese in utero-exposed atomic bomb survivors.

  12. New method of limb deformities correction in children.

    PubMed Central

    Atar, D.; Lehman, W. B.; Grant, A. D.; Strongwater, A.; Frankel, V. H.; Posner, M.; Golyakhovsky, V.

    1992-01-01

    A new "bloodless" technique (Ilizarov) was used to correct 36 limb deformities in 29 children. There were six leg length discrepancies, five achondroplasias, four deformed feet, five joint contractures, one rotational deformity of tibia, and in three the apparatus was used as an external fixator after corrective osteotomy. Lengthening was accomplished in 15 of the 16 procedures (93%). Average increase in femur length was 10 cm (32%), in tibial length 7.5 cm (30%), in humerus 11 cm (40%). Bony union was achieved in two out of five pseudoarthroses. Four deformed feet were fully corrected. Joint contractures were corrected in four out of five. The complication rate is as high as in other methods but with the Ilizarov apparatus, longer segments of bone were lengthened and more complex deformities were treated. Complications lessened as experience was gained. Images Fig. 1a,b Fig. 1 Fig. 1c Fig. 1d Fig. 1e Fig. 2a Fig. 2b Fig. 2c Fig. 2d Fig. 2e Fig. 3a Fig. 3b Fig. 3c Fig. 3d Fig. 4a Fig. 4b Fig. 4c Fig. 4d Fig. 4e Fig. 5a Fig. 5b Fig. 5c Fig. 5d PMID:1490205

  13. Near ultraviolet photodissociation spectroscopy of Mn+(H2O) and Mn+(D2O)

    NASA Astrophysics Data System (ADS)

    Pearson, Wright L.; Copeland, Christopher; Kocak, Abdulkadir; Sallese, Zachary; Metz, Ricardo B.

    2014-11-01

    The electronic spectra of Mn+(H2O) and Mn+(D2O) have been measured from 30 000 to 35 000 cm-1 using photodissociation spectroscopy. Transitions are observed from the 7A1 ground state in which the Mn+ is in a 3d54s1 electronic configuration, to the 7B2 (3d54py) and 7B1 (3d54px) excited states with T0 = 30 210 and 32 274 cm-1, respectively. Each electronic transition has partially resolved rotational and extensive vibrational structure with an extended progression in the metal-ligand stretch at a frequency of ˜450 cm-1. There are also progressions in the in-plane bend in the 7B2 state, due to vibronic coupling, and the out-of-plane bend in the 7B1 state, where the calculation illustrates that this state is slightly non-planar. Electronic structure computations at the CCSD(T)/aug-cc-pVTZ and TD-DFT B3LYP/6-311++G(3df,3pd) level are also used to characterize the ground and excited states, respectively. These calculations predict a ground state Mn-O bond length of 2.18 Å. Analysis of the experimentally observed vibrational intensities reveals that this bond length decreases by 0.15 ± 0.015 Å and 0.14 ± 0.01 Å in the excited states. The behavior is accounted for by the less repulsive px and py orbitals causing the Mn+ to interact more strongly with water in the excited states than the ground state. The result is a decrease in the Mn-O bond length, along with an increase in the H-O-H angle. The spectra have well resolved K rotational structure. Fitting this structure gives spin-rotation constants ɛaa″ = -3 ± 1 cm-1 for the ground state and ɛaa' = 0.5 ± 0.5 cm-1 and ɛaa' = -4.2 ± 0.7 cm-1 for the first and second excited states, respectively, and A' = 12.8 ± 0.7 cm-1 for the first excited state. Vibrationally mediated photodissociation studies determine the O-H antisymmetric stretching frequency in the ground electronic state to be 3658 cm-1.

  14. Weather and children's physical activity; how and why do relationships vary between countries?

    PubMed

    Harrison, Flo; Goodman, Anna; van Sluijs, Esther M F; Andersen, Lars Bo; Cardon, Greet; Davey, Rachel; Janz, Kathleen F; Kriemler, Susi; Molloy, Lynn; Page, Angie S; Pate, Russ; Puder, Jardena J; Sardinha, Luis B; Timperio, Anna; Wedderkopp, Niels; Jones, Andy P

    2017-05-30

    Globally most children do not engage in enough physical activity. Day length and weather conditions have been identified as determinants of physical activity, although how they may be overcome as barriers is not clear. We aim to examine if and how relationships between children's physical activity and weather and day length vary between countries and identify settings in which children were better able to maintain activity levels given the weather conditions they experienced. In this repeated measures study, we used data from 23,451 participants in the International Children's Accelerometry Database (ICAD). Daily accelerometer-measured physical activity (counts per minute; cpm) was matched to local weather conditions and the relationships assessed using multilevel regression models. Multilevel models accounted for clustering of days within occasions within children within study-cities, and allowed us to explore if and how the relationships between weather variables and physical activity differ by setting. Increased precipitation and wind speed were associated with decreased cpm while better visibility and more hours of daylight were associated with increased cpm. Models indicated that increases in these variables resulted in average changes in mean cpm of 7.6/h of day length, -13.2/cm precipitation, 10.3/10 km visibility and -10.3/10kph wind speed (all p < 0.01). Temperature showed a cubic relationship with cpm, although between 0 and 20 degrees C the relationship was broadly linear. Age showed interactions with temperature and precipitation, with the associations larger among younger children. In terms of geographic trends, participants from Northern European countries and Melbourne, Australia were the most active, and also better maintained their activity levels given the weather conditions they experienced compared to those in the US and Western Europe. We found variation in the relationship between weather conditions and physical activity between ICAD studies and settings. Children in Northern Europe and Melbourne, Australia were not only more active on average, but also more active given the weather conditions they experienced. Future work should consider strategies to mitigate the impacts of weather conditions, especially among young children, and interventions involving changes to the physical environment should consider how they will operate in different weather conditions.

  15. Low-birthweight rates higher among Bangladeshi neonates measured during active birth surveillance compared to national survey data.

    PubMed

    Klemm, Rolf D W; Merrill, Rebecca D; Wu, Lee; Shamim, Abu Ahmed; Ali, Hasmot; Labrique, Alain; Christian, Parul; West, Keith P

    2015-10-01

    Birth size is an important gauge of fetal and neonatal health. Birth size measurements were collected within 72 h of life for 16 290 live born, singleton infants in rural Bangladesh from 2004 to 2007. Gestational age was calculated based on the date of last menstrual period. Newborns were classified as small-for-gestational age (SGA) based on a birthweight below the 10th percentile for gestational age, using three sets of US reference data. Birth size distributions were explored based on raw values as well as after z-score standardisation in reference to World Health Organization (WHO) 2006 growth standards. Mean (SD) birthweight (g), length (cm) and head circumference (cm) measurements, completed within [median (25th, 75th percentile)] 15 (8, 23) h of life, were 2433 (425), 46.4 (2.4) and 32.4 (1.6), respectively. Twenty-two per cent were born preterm. Over one-half (55.3%) of infants were born low birthweight; 46.6%, 37.0% and 33.6% had a weight, length and head circumference below -2 z-scores of the WHO growth standard at birth; and 70.9%, 72.2% and 59.8% were SGA for weight based on Alexander et al., Oken et al. and Olsen et al. references, respectively. Infants in this typical rural Bangladesh setting were commonly born small, reflecting a high burden of fetal growth restriction and preterm birth. Our findings, produced by active birth surveillance, suggest that low birthweight is far more common than suggested by cross-sectional survey estimates. Interventions that improve fetal growth during pregnancy may have the largest impact on reducing SGA rates. © 2013 John Wiley & Sons Ltd.

  16. Synthesis, crystal structure and high temperature phase transition in the new organic-inorganic hybrid [N(C4H9)4]3Zn2Cl7H2O crystals

    NASA Astrophysics Data System (ADS)

    Ben Gzaiel, Malika; Oueslati, Abderrazek; Lhoste, Jérôme; Gargouri, Mohamed; Bulou, Alain

    2015-06-01

    The present paper accounts for the synthesis, crystal structure, differential scanning calorimetry and vibrational spectroscopy of a new compound tri-tetrabutylammonium heptachloro-dizincate (I) grown at room temperature by slow evaporation of aqueous solution. From X-ray diffraction data collected at room temperature, it is concluded that it crystallizes in the monoclinic system (P21/n space group) containing ZnCl42- and ZnCl3H2O1- tetrahedra. The atomic arrangement can be described by an alternation of organic and organic-inorganic layers stacked along the c direction. Differential scanning calorimetry (DSC) in the range 250-450 K disclosed a reversible structural phase transition of order-disorder type at 358 K, prior to the melting at 395 K. The temperature dependence of the Raman spectra of [N(C4H9)4]3Zn2Cl7H2O single crystals was studied in the spectral range 100-3500 cm-1 and for temperatures between 300 and 386 K. The most important changes are observed for the line at 261 cm-1 issued from ν1(ZnCl4). The analysis of the wavenumber, intensity and the line width based on an order-disorder model allowed to obtain information relative to the activation energy and the correlation length. The decrease of the activation energy with increasing temperature has been interpreted in term of a change in the re-orientation motion of the anionic parts. The assumption of cluster fluctuations also allowed the critical exponents to be obtained for the transition δ = 0.011 and the correlation length ξ0 = 598 Å.

  17. Constant DI pacing suppresses cardiac alternans formation in numerical cable models

    NASA Astrophysics Data System (ADS)

    Zlochiver, S.; Johnson, C.; Tolkacheva, E. G.

    2017-09-01

    Cardiac repolarization alternans describe the sequential alternation of the action potential duration (APD) and can develop during rapid pacing. In the ventricles, such alternans may rapidly turn into life risking arrhythmias under conditions of spatial heterogeneity. Thus, suppression of alternans by artificial pacing protocols, or alternans control, has been the subject of numerous theoretical, numerical, and experimental studies. Yet, previous attempts that were inspired by chaos control theories were successful only for a short spatial extent (<2 cm) from the pacing electrode. Previously, we demonstrated in a single cell model that pacing with a constant diastolic interval (DI) can suppress the formation of alternans at high rates of activation. We attributed this effect to the elimination of feedback between the pacing cycle length and the last APD, effectively preventing restitution-dependent alternans from developing. Here, we extend this idea into cable models to study the extent by which constant DI pacing can control alternans during wave propagation conditions. Constant DI pacing was applied to ventricular cable models of up to 5 cm, using human kinetics. Our results show that constant DI pacing significantly shifts the onset of both cardiac alternans and conduction blocks to higher pacing rates in comparison to pacing with constant cycle length. We also demonstrate that constant DI pacing reduces the propensity of spatially discordant alternans, a precursor of wavebreaks. We finally found that the protective effect of constant DI pacing is stronger for increased electrotonic coupling along the fiber in the sense that the onset of alternans is further shifted to higher activation rates. Overall, these results support the potential clinical applicability of such type of pacing in improving protocols of implanted pacemakers, in order to reduce the risk of life-threatening arrhythmias. Future research should be conducted in order to experimentally validate these promising results.

  18. Determination of carrier lifetime and diffusion length in Al-doped 4H-SiC epilayers by time-resolved optical techniques

    NASA Astrophysics Data System (ADS)

    Liaugaudas, Gediminas; Dargis, Donatas; Kwasnicki, Pawel; Arvinte, Roxana; Zielinski, Marcin; Jarašiūnas, Kęstutis

    2015-01-01

    A series of p-type 4H-SiC epilayers with aluminium concentration ranging from 2  ×  1016 to 8  ×  1019 cm-3 were investigated by time-resolved optical techniques in order to determine the effect of aluminium doping on high-injection carrier lifetime at room temperature and the diffusion coefficient at different injections (from ≈3  ×  1018 to ≈5  ×  1019 cm-3) and temperatures (from 78 to 730 K). We find that the defect limited carrier lifetime τSRH decreases from 20 ns in the low-doped samples down to ≈0.6 ns in the heavily doped epilayers. Accordingly, the ambipolar diffusion coefficient decreases from Da = 3.5 cm2 s-1 down to ≈0.6 cm2 s-1, corresponding to the hole mobility of µh = 70 cm2 Vs-1 and 12 cm2 Vs-1, respectively. In the highly doped epilayers, the injection-induced decrease of the diffusion coefficient, due to the transition from the minority carrier diffusion to the ambipolar diffusion, provided the electron diffusion coefficient of De ≈ 3 cm2 s-1. The Al-doping resulted in the gradual decrease of the ambipolar diffusion length, from LD = 2.7 µm down to LD = 0.25 µm in the epilayers with the lowest and highest aluminium concentrations.

  19. Percutaneous epiphysiodesis using transphyseal screws for limb-length discrepancies: high variability among growth predictor models.

    PubMed

    Monier, Bryan C; Aronsson, David D; Sun, Michael

    2015-10-01

    Percutaneous epiphysiodesis using transphyseal screws (PETS) was developed as a minimally invasive outpatient procedure to address limb-length discrepancy (LLD) that allowed immediate postoperative weight bearing and was potentially reversible by removing the screws. The aims of our study were to report our results using PETS for LLD and evaluate the accuracy of three growth predictor models. Sixteen patients with an average age of 14 years were treated for LLD using PETS. Thirteen patients had screws inserted in a parallel fashion and 3 had crossed screws. We compared the predicted LLD at skeletal maturity using the three growth predictor methods with the actual LLD at skeletal maturity and preoperative LLD with the final LLD at skeletal maturity. The mean LLD at skeletal maturity between the predicted and final measurements was 0.2 cm using the Green-Anderson method, 1.4 cm using the Moseley method, and -0.1 cm using the Paley method. The mean preoperative LLD of 3.1 cm was corrected to 1.7 cm at skeletal maturity (p < 0.001). Six patients complained of pain over the screw heads; however, no patient developed an infection or angular deformity. The three growth predictor methods predicted the final LLD within an average of 1.4 cm, but there was high variability. Although PETS improved the LLD by a mean of 1.4 cm, we believe the results would have been better if PETS was performed at an earlier skeletal age.

  20. Fully covered self-expanding metallic stent placement for benign refractory esophageal strictures.

    PubMed

    Kahalekar, Vinit; Gupta, Deepak Trilokinath; Bhatt, Pratin; Shukla, Akash; Bhatia, Shobna

    2017-05-01

    Treatment options for benign refractory esophageal stricture are limited. We retrospectively analyzed data of 11 patients who underwent fully covered self-expanding metallic stent (FC-SEMS) placement for refractory benign esophageal stricture at our institute. Refractory benign esophageal stricture was defined as inability to dilate a stricture to a diameter of 14 mm after a minimum of five sessions at 2-week intervals or inability to maintain diameter of 14 mm for at least 4 weeks. Eleven patients with refractory benign esophageal stricture (corrosive-6, peptic-3, and post-sclerotherapy-2) underwent FC-SEMS placement. The stent was removed after 4-6 weeks as per manufacturer's recommendation. Patients were followed up for 1 year. Three patients with peptic strictures [length of stricture 2, 3, and 3 cm] and two patients with post-sclerotherapy stricture [length 2 and 1.5 cm] had complete response. Two of 6 patients with corrosive stricture (10 cm, 12 cm) developed recurrence of symptoms within 1 month of stent removal, and two after 2 months (8 cm, 3 cm). One patient with corrosive stricture (6 cm) had recurrence after 6 months, and responded to single session of dilatation. One patient with corrosive stricture was asymptomatic for last 12 months. Four stents were migrated. Four patients developed severe retrosternal pain following stent placement, which was managed with analgesics. There were no serious adverse events after placement of stent and removal of stent. Fully covered SEMS is safe and effective for refractory benign non-corrosive esophageal strictures.

  1. Tolerability of donkey's milk in 92 highly-problematic cow's milk allergic children.

    PubMed

    Monti, G; Viola, S; Baro, C; Cresi, F; Tovo, P A; Moro, G; Ferrero, M P; Conti, A; Bertino, E

    2012-01-01

    Not exclusively breastfed children with cow's milk allergy (CMA) require a formula or other alternative food, but past and present guidelines differ concerning the best choice. Our aim was to investigate the clinical tolerability, palatability and nutritional adequacy of donkey's milk (DM) in children with proven CMA. It was important to identify a CM replacement for these children, highly problematic from the feeding standpoint, in spite of their age. A prospective study was conducted on 92 children with CMA, diagnosed through a CM elimination diet, followed by double-blind, placebo-controlled food challenge (DBPCFC) unless contraindicated. Maternal milk was unavailable and current CM substitutes could not be used. Moreover, 89 percent were affected by multiple FA, and subjected to very restricted diets. Within 3 months after the last CM challenge, DBPCFC for DM was performed. CM or DM skin prick test and sIgE determination preceded the CM or DM challenge, respectively. Native electrophoresis and immunoblotting were used to identify CM and DM cross-reactive proteins. Z-scores of weight and length/stature for age were calculated at DM food challenge (T0) and during DM assumption. 83 children (90.2 percent) liked and tolerated DM, at challenge and during follow-up, with increased Z-score for weight and length/stature and improved nutritional parameters. Bovine beta-lactoglobulin was identified as the cross-reacting protein among the DM allergic patients. DM was found to be a valid alternative foodstuff, in terms of clinical tolerability, palatability and nutritional adequacy, in subjects with CMA who were highly problematic from the feeding standpoint.

  2. Active phase correction of high resolution silicon photonic arrayed waveguide gratings

    DOE PAGES

    Gehl, M.; Trotter, D.; Starbuck, A.; ...

    2017-03-10

    Arrayed waveguide gratings provide flexible spectral filtering functionality for integrated photonic applications. Achieving narrow channel spacing requires long optical path lengths which can greatly increase the footprint of devices. High index contrast waveguides, such as those fabricated in silicon-on-insulator wafers, allow tight waveguide bends which can be used to create much more compact designs. Both the long optical path lengths and the high index contrast contribute to significant optical phase error as light propagates through the device. Thus, silicon photonic arrayed waveguide gratings require active or passive phase correction following fabrication. We present the design and fabrication of compact siliconmore » photonic arrayed waveguide gratings with channel spacings of 50, 10 and 1 GHz. The largest device, with 11 channels of 1 GHz spacing, has a footprint of only 1.1 cm 2. Using integrated thermo-optic phase shifters, the phase error is actively corrected. We present two methods of phase error correction and demonstrate state-of-the-art cross-talk performance for high index contrast arrayed waveguide gratings. As a demonstration of possible applications, we perform RF channelization with 1 GHz resolution. In addition, we generate unique spectral filters by applying non-zero phase offsets calculated by the Gerchberg Saxton algorithm.« less

  3. Active phase correction of high resolution silicon photonic arrayed waveguide gratings.

    PubMed

    Gehl, M; Trotter, D; Starbuck, A; Pomerene, A; Lentine, A L; DeRose, C

    2017-03-20

    Arrayed waveguide gratings provide flexible spectral filtering functionality for integrated photonic applications. Achieving narrow channel spacing requires long optical path lengths which can greatly increase the footprint of devices. High index contrast waveguides, such as those fabricated in silicon-on-insulator wafers, allow tight waveguide bends which can be used to create much more compact designs. Both the long optical path lengths and the high index contrast contribute to significant optical phase error as light propagates through the device. Therefore, silicon photonic arrayed waveguide gratings require active or passive phase correction following fabrication. Here we present the design and fabrication of compact silicon photonic arrayed waveguide gratings with channel spacings of 50, 10 and 1 GHz. The largest device, with 11 channels of 1 GHz spacing, has a footprint of only 1.1 cm2. Using integrated thermo-optic phase shifters, the phase error is actively corrected. We present two methods of phase error correction and demonstrate state-of-the-art cross-talk performance for high index contrast arrayed waveguide gratings. As a demonstration of possible applications, we perform RF channelization with 1 GHz resolution. Additionally, we generate unique spectral filters by applying non-zero phase offsets calculated by the Gerchberg Saxton algorithm.

  4. Biological observations on the crocodile shark Pseudocarcharias kamoharai.

    PubMed

    Dai, X J; Zhu, J F; Chen, X J; Xu, L X; Chen, Y

    2012-04-01

    Sex ratios and gravid characteristics were analysed for the crocodile shark Pseudocarcharias kamoharai from the tropical eastern Pacific Ocean. Gravid females ranged from 80 to 102 cm fork length (L(F) ). The mode litter size was four (two embryos per uterus), mean embryo length was linearly correlated with maternal length (r = 0·465, n = 32); there was no significant difference in L(F) between female and male embryos. © 2011 The Authors. Journal of Fish Biology © 2011 The Fisheries Society of the British Isles.

  5. Urethroplasty for treatment of long anterior urethral stricture: buccal mucosa graft versus penile skin graft-does the stricture length matter?

    PubMed

    Hussein, Mohamed M; Almogazy, Hazem; Mamdouh, Ahmed; Farag, Fawzy; Rashed, Elnesr; Gamal, Wael; Rashed, Ahmed; Zaki, Mohamed; Salem, Esam; Ryad, Ahmed

    2016-11-01

    To investigate the surgical outcomes of dorsal onlay urethroplasty (DOU) using buccal mucosa graft (BMG) or penile skin graft (PSG) and to assess the effect of stricture length in men with anterior urethral strictures. A prospective cohort included men with anterior urethral strictures between 2008 and 2015. Patients underwent DOU using PSG or BMG. Patients had urethrography and uroflowmetry at 0, 3, 6, 12 months, and urethroscopy when needed. Student's t test, Mann-Whitney U tests, and Pearson's Chi-square test were used for analysis. Sixty-nine patients (43 ± 14 year) were included, 31 received BMG, and 38 received PSG. Mean stricture length was 8 ± 3 cm, mean operative time was 145 ± 31 min, and mean follow-up was 56 ± 10 mo. Success rate was 87 % (90 % BMG vs. 84 % PSG, p = 0.4). Mean operative time was significantly shorter in PSG group (136 ± 29 min vs. 256 ± 58 min, p = 0.0005). Complications of grade I developed in 36 % (wound infection = 10 %, postvoiding dribbling = 18.8 %). Thirty of 69 patients (43 %) had strictures ≥8 cm, and 39 (57 %) had strictures <8 cm-success rate was equal for both subgroups (87 %). Mean blood loss, mean operative time, and incidence of postvoid dribbling were significantly lower in strictures <8 cm. BMG and PSG have comparable success rates in treatment of long anterior urethral strictures. Operative time is significantly longer in BMG. Long-segment strictures are associated with longer operative time, more blood loss, and more occurrence of postvoid dribbling. However, the length of the stricture has no influence on the success rate and functional outcomes of DOU.

  6. Effects of Including Misidentified Sharks in Life History Analyses: A Case Study on the Grey Reef Shark Carcharhinus amblyrhynchos from Papua New Guinea

    PubMed Central

    Smart, Jonathan J.; Chin, Andrew; Baje, Leontine; Green, Madeline E.; Appleyard, Sharon A.; Tobin, Andrew J.; Simpfendorfer, Colin A.; White, William T.

    2016-01-01

    Fisheries observer programs are used around the world to collect crucial information and samples that inform fisheries management. However, observer error may misidentify similar-looking shark species. This raises questions about the level of error that species misidentifications could introduce to estimates of species’ life history parameters. This study addressed these questions using the Grey Reef Shark Carcharhinus amblyrhynchos as a case study. Observer misidentification rates were quantified by validating species identifications using diagnostic photographs taken on board supplemented with DNA barcoding. Length-at-age and maturity ogive analyses were then estimated and compared with and without the misidentified individuals. Vertebrae were retained from a total of 155 sharks identified by observers as C. amblyrhynchos. However, 22 (14%) of these were sharks were misidentified by the observers and were subsequently re-identified based on photographs and/or DNA barcoding. Of the 22 individuals misidentified as C. amblyrhynchos, 16 (73%) were detected using photographs and a further 6 via genetic validation. If misidentified individuals had been included, substantial error would have been introduced to both the length-at-age and the maturity estimates. Thus validating the species identification, increased the accuracy of estimated life history parameters for C. amblyrhynchos. From the corrected sample a multi-model inference approach was used to estimate growth for C. amblyrhynchos using three candidate models. The model averaged length-at-age parameters for C. amblyrhynchos with the sexes combined were  L¯∞ = 159 cm TL and  L¯0 = 72 cm TL. Females mature at a greater length (l50 = 136 cm TL) and older age (A50 = 9.1 years) than males (l50 = 123 cm TL; A50 = 5.9 years). The inclusion of techniques to reduce misidentification in observer programs will improve the results of life history studies and ultimately improve management through the use of more accurate data for assessments. PMID:27058734

  7. Atherectomy-Associated Complications in the Southern California Vascular Outcomes Improvement Collaborative.

    PubMed

    Azar, Yara; DeRubertis, Brian; Baril, Donald; Woo, Karen

    2018-05-01

    Atherectomy has become an increasingly utilized modality for the endovascular treatment of peripheral arterial occlusive disease. The objective of this study was to determine the incidence and risk factors for atherectomy-associated complications. A retrospective review was performed for all atherectomy procedures performed between January 2011 and December 2015 in the Southern California Vascular Outcomes Improvement Collaborative. Atherectomy was defined as laser, orbital, or excisional atherectomy. Complications were dissection, perforation, and distal embolization. Seven hundred twenty-nine atherectomy procedures were performed at 7 institutions by 27 practitioners. The mean age was 73 years with 415 (57%) males. Four hundred nineteen (57%) were diabetic, 673 (92%) hypertensive, 457 (63%) smokers, and 244 (34%) had coronary artery disease. Dissection occurred in 51 (7%) procedures, embolization in 23 (3.1%), and perforation in 12 (1.6%). The mean number of lesions treated per artery was the same at 1.6 in patients with any complication and no complication (P = 0.77). The total occluded length was 7.4 cm for complications versus 7.2 cm for no complication (P = 0.73). The total treated length was 12.9 cm for complications versus 11.3 cm for no complication (P = 0.03). The incidence of complications for Trans-Atlantic Inter-Society Consensus (TASC) C/D lesions were 13% compared to 10% for TASC A/B lesions (P = 0.05). The incidence of complications in superficial femoral/popliteal lesions was 12.9% vs. 10.4% in tibial lesions (P = 0.13). In multivariable analysis, treatment length was associated with a small increased risk of complication (odds ratio = 1.02, 95% confidence interval = 1.0-1.04). Increased treatment length is associated with an increased risk of atherectomy-associated complications. Demographic factors and comorbidities were not predictors of complications. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Effects of Including Misidentified Sharks in Life History Analyses: A Case Study on the Grey Reef Shark Carcharhinus amblyrhynchos from Papua New Guinea.

    PubMed

    Smart, Jonathan J; Chin, Andrew; Baje, Leontine; Green, Madeline E; Appleyard, Sharon A; Tobin, Andrew J; Simpfendorfer, Colin A; White, William T

    2016-01-01

    Fisheries observer programs are used around the world to collect crucial information and samples that inform fisheries management. However, observer error may misidentify similar-looking shark species. This raises questions about the level of error that species misidentifications could introduce to estimates of species' life history parameters. This study addressed these questions using the Grey Reef Shark Carcharhinus amblyrhynchos as a case study. Observer misidentification rates were quantified by validating species identifications using diagnostic photographs taken on board supplemented with DNA barcoding. Length-at-age and maturity ogive analyses were then estimated and compared with and without the misidentified individuals. Vertebrae were retained from a total of 155 sharks identified by observers as C. amblyrhynchos. However, 22 (14%) of these were sharks were misidentified by the observers and were subsequently re-identified based on photographs and/or DNA barcoding. Of the 22 individuals misidentified as C. amblyrhynchos, 16 (73%) were detected using photographs and a further 6 via genetic validation. If misidentified individuals had been included, substantial error would have been introduced to both the length-at-age and the maturity estimates. Thus validating the species identification, increased the accuracy of estimated life history parameters for C. amblyrhynchos. From the corrected sample a multi-model inference approach was used to estimate growth for C. amblyrhynchos using three candidate models. The model averaged length-at-age parameters for C. amblyrhynchos with the sexes combined were L∞ = 159 cm TL and L0 = 72 cm TL. Females mature at a greater length (l50 = 136 cm TL) and older age (A50 = 9.1 years) than males (l50 = 123 cm TL; A50 = 5.9 years). The inclusion of techniques to reduce misidentification in observer programs will improve the results of life history studies and ultimately improve management through the use of more accurate data for assessments.

  9. Novel measurements of the length of the subglottic airway in infants and young children.

    PubMed

    Sirisopana, Metee; Saint-Martin, Christine; Wang, Ning Nan; Manoukian, John; Nguyen, Lily H P; Brown, Karen A

    2013-08-01

    To date, the lengths of the subglottic and tracheal airway segments have been measured from autopsy specimens. Images of the head and neck obtained from computerized tomography (CT) provide an alternate method. Our objective in this study was to identify anatomic landmarks from CT scans in infants and young children to estimate the lengths of the subglottic and tracheal airway segments and to correlate these lengths with age. We performed a retrospective analysis of CT images of the neck for various diagnostic indications in children ≤3 years. We obtained planes of reconstruction at the level of the vocal cords (VCs), cricoid cartilage, and carina (C) which were parallel to each other and perpendicular to sagittal long axis of the trachea. The lengths of the subglottic airway (LengthSG) and total length of the laryngotracheal airway (LengthVC-C) were measured from the distance between, respectively, the VC versus cricoid cartilage and the VC versus C planes of reconstruction. Tracheal length was then calculated as the difference between LengthVC-C and LengthSG. Fifty-six children met the inclusion criteria. There were 29 boys. The median weight was 10.7 kg (range 3.1-19.0 kg). Regression analysis yielded mean LengthSG (mm) = 7.8 + 0.03·corrected age (months), r(2) = 0.07, P = 0.056; lower and upper 95% confidence interval for β = 0.03 were -0.001 and 0061. The mean LengthSG was 8.4 mm with an SD of 1.4 mm. The 95th percentile for LengthSG was 10.8 mm, and the 5% to 95% interquartile range was 4.9 mm. The estimate for the 95% confidence interval of the 95th percentile was between 10.2 and 11.3 mm. The LengthVC-C increased with age: mean LengthVC-C (cm) = 5.3 + 0.05·corrected age (months), r(2) = 0.7, P < 0.001. Tracheal length also increased with age: mean tracheal length (cm) = 4.5 + 0.05·corrected age (months), r(2) = 0.6, P < 0.001. We report a novel estimate method for the lengths of the airway segments between the VC and C in 56 infants and young children and suggest that the growth characteristics of the subglottic and tracheal airway may differ.

  10. [Effect of highly active anti-retroviral therapy on prevention of mother to child transmission of HIV and on infant growth and development].

    PubMed

    He, Yan; Luo, Yan; Ding, Yi-ling; Zheng, Yu-huang; Li, Jing; Huang, Jian; Li, Jie-min

    2011-10-01

    To identify the effect of highly active anti-retroviral therapy (HAART) on prevention of mother to child transmission (PMTCT) of HIV and on infant growth and development. A total of 16 HIV-infected women or pregnant women selected in this study received HAART before or 18 - 24 weeks after pregnancy. The treatment included taking Zidovudine (AZT) 0.3 g each time, twice a day, Lamivudine (3TC) 0.3 g each time, once a day and Nevirapine (NVP) 0.2 g each time, twice a day or Efavirenz (EFV) 0.6 g each time, once a day, as well as labor intervention and artificial feeding. The growth index for 17 infants from HIV-infected mothers (experimental group) and 16 normal infants (control group) were observed for 18 months. Neonatal hemoglobin (Hb), liver and kidney function, serum iron and calcium were detected at neonatal period and at 12(th) month, respectively. All the pregnant women were in good conditions and had tolerance with HAART. The birth weight, length and Apgar score of the newborns in the experimental group were (3.5 ± 0.9) kg, (54.2 ± 3.8) cm and 7 - 10 scores respectively, however those in the control group were (3.6 ± 0.8) kg, (55.6 ± 3.6) cm and 8 - 10 scores (t(weight) = 1.01, t(length) = 6.98, P > 0.05). Weight and length of infants in experimental group were (9.36 ± 1.8) kg and (76.3 ± 2.7) cm at 12(th) month, while those in control group were (9.86 ± 2.5) kg and (76.8 ± 2.9) cm (t(weight) = 0.83, t(length) = 1.00, P > 0.05). The level of Hb in experimental group was (126.2 ± 16.7) g/L, and was (148.6 ± 20.5) g/L in control group (t = -5.89, P = 0.11). At 12(th) month, the levels of Hb and the total bilirubin (TB) were (125.9 ± 19.8) g/L and (11.7 ± 3.5) µmol/L in experimental group; and those in the control group were (130.1 ± 18.7) g/L and (13.2 ± 3.7) µmol/L (t(Hb) = -3.82, t(TB) = -2.14, P > 0.05). Serum iron and calcium were (25.4 ± 5.7) µmol/L and (26.4 ± 7.2) µmol/L at neonatal period and were (2.3 ± 0.6) mol/L and (2.8 ± 0.6) mol/L at 12(th) month in experimental group, while those were (26.2 ± 4.9) µmol/L and (28.1 ± 6.9) µmol/L at neonatal period and were (2.6 ± 0.5) mol/L and (3.1 ± 0.5) mol/L at 12(th) month in the control group (t(Fe) = 0.80 and t(Ca) = -3.00 in neonatal period, t(Fe) = -1.50 and t(Ca) = -1.00 at 12(th) month, P > 0.05). All infants of HIV-infected mothers were not infected with HIV when they were 18 months old. HAART can prevent mother to child transmission of HIV and it was not found to influence the baby's growth and development in this study.

  11. Volumetric Growth of the Liver in the Human Fetus: An Anatomical, Hydrostatic, and Statistical Study

    PubMed Central

    Szpinda, Michał; Paruszewska-Achtel, Monika; Mila-Kierzenkowska, Celestyna; Elminowska-Wenda, Gabriela; Dombek, Małgorzata; Szpinda, Anna; Badura, Mateusz

    2015-01-01

    Using anatomical, hydrostatic, and statistical methods, liver volumes were assessed in 69 human fetuses of both sexes aged 18–30 weeks. No sex differences were found. The median of liver volume achieved by hydrostatic measurements increased from 6.57 cm3 at 18–21 weeks through 14.36 cm3 at 22–25 weeks to 20.77 cm3 at 26–30 weeks, according to the following regression: y = −26.95 + 1.74 × age ± Z  × (−3.15 + 0.27 × age). The median of liver volume calculated indirectly according to the formula liver volume = 0.55 × liver length × liver transverse diameter × liver sagittal diameter increased from 12.41 cm3 at 18–21 weeks through 28.21 cm3 at 22–25 weeks to 49.69 cm3 at 26–30 weeks. There was a strong relationship (r = 0.91, p < 0.001) between the liver volumes achieved by hydrostatic (x) and indirect (y) methods, expressed by y = −0.05 + 2.16x  ± 7.26. The liver volume should be calculated as follows liver volume = 0.26 × liver length × liver transverse diameter × liver sagittal diameter. The age-specific liver volumes are of great relevance in the evaluation of the normal hepatic growth and the early diagnosis of fetal micro- and macrosomias. PMID:26413551

  12. Flexible nine-channel photodetector probe facilitated intraspinal multisite transcutaneous photobiomodulation therapy dosimetry in cadaver dogs

    NASA Astrophysics Data System (ADS)

    Piao, Daqing; Sypniewski, Lara A.; Bailey, Christian; Dugat, Danielle; Burba, Daniel J.; De Taboada, Luis

    2018-01-01

    Noninvasive photobiomodulation therapy (PBMT) of spinal cord disease remains speculative due to the lack of evidence for whether photobiomodulatory irradiances can be transcutaneously delivered to the spinal cord under a clinically acceptable PBMT surface irradiation protocol. We developed a flexible nine-channel photodetection probe for deployment within the spinal canal of a cadaver dog after hemilaminectomy to measure transcutaneously transmitted PBMT irradiance at nine sites over an eight-cm spinal canal length. The probe was built upon a 6.325-mm tubular stem, to the surface of which nine photodiodes were epoxied at approximately 1 cm apart. The photodiode has a form factor of 4.80 mm×2.10 mm×1.15 mm (length×width×height). Each photodiode was individually calibrated to deliver 1 V per 7.58 μW/cm2 continuous irradiance at 850 nm. The outputs of eight photodiodes were logged concurrently using a data acquisition module interfacing eight channels of differential analog signals, while the output of the ninth photodiode was measured by a precision multimeter. This flexible probe rendered simultaneous intraspinal (nine-site) measurements of transcutaneous PBMT irradiations at 980 nm in a pilot cadaver dog model. At a surface continuous irradiance of 3.14 W/cm2 applied off-contact between L1 and L2, intraspinal irradiances picked up by nine photodiodes had a maximum of 327.48 μW/cm2 without the skin and 5.68 μW/cm2 with the skin.

  13. Giant midline abdominal incisional herniae repair through combined retro-rectus mesh placement and components separation: experience from a single centre.

    PubMed

    Kumar, R; Shrestha, A K; Basu, S

    2014-10-01

    Giant midline abdominal wall incisional herniae require repair/reconstruction to restore the structural and functional continuity of the anterior abdominal wall. We describe here our approach to these demanding cases through a combined retro-rectus mesh placement and components separation and their overall functional outcome. A retrospective analysis of a prospectively collected data was carried out and 28 patients who underwent giant (≥15 cm) midline incisional hernia reconstruction were identified in a large district general hospital between 2007 and 2013 with a median follow-up of 34 (6-76) months. Demographic data of our series include age of 60 (median) (30-87) years with a M:F ratio of 12:16, length of symptomatic hernia 18 (median) (12-36) months, more than two previous laparotomies (15), bowel obstructive symptoms (7) and recurrent herniation (7). BMI recorded was 32 (median) (24-46) and ASA of II (median) (I-III). Co-morbidities included cardiac disease (6), diabetes (6), respiratory disease (4) and systemic immunocompromise (2). Operative and technical details showed operative duration to be 180 (median) min, cranio-caudal rectus sheath defect 21 (median) cm, transverse rectus sheath defect 15 (median) cm, cross-sectional area of fascial defect 300 (median) cm(2) and size of mesh 690 (median) cm(2). Seven (25 %) developed short-term post operative complications: grade I seromata all resolving spontaneously (5); grade II superficial wound infections (2). Twenty-five (89 %) were completely asymptomatic at 34 (median) months' follow-up; 2 (7 %) reported mild pain, but not limiting any activity; 1 (4 %) described pain occasionally limiting activity. There was no clinical recurrence with one patient developing global bulging. Our series is comparable to the literature in patient cohort demographics, co-morbidity and risk factor profile; however, we demonstrate an excellent intermediate term outcome with no clinical recurrence and an improvement in quality of life, through their ability to perform normal day to day activities.

  14. Evaluation of factors affecting soil carbon sequestration services of stormwater wet retention ponds in varying climate zones.

    PubMed

    Merriman, L S; Moore, T L C; Wang, J W; Osmond, D L; Al-Rubaei, A M; Smolek, A P; Blecken, G T; Viklander, M; Hunt, W F

    2017-04-01

    The carbon sequestration services of stormwater wet retention ponds were investigated in four different climates: U.S., Northern Sweden, Southern Sweden, and Singapore, representing a range of annual mean temperatures, growing season lengths and rainfall depths: geographic factors that were not statistically compared, but have great effect on carbon (C) accumulation. A chronosequence was used to estimate C accumulations rates; C accumulation and decomposition rates were not directly measured. C accumulated significantly over time in vegetated shallow water areas (0-30cm) in the USA (78.4gCm -2 yr -1 ), in vegetated temporary inundation zones in Sweden (75.8gCm -2 yr -1 ), and in all ponds in Singapore (135gCm -2 yr -1 ). Vegetative production appeared to exert a stronger influence on relative C accumulation rates than decomposition. Comparing among the four climatic zones, the effects of increasing rainfall and growing season lengths (vegetative production) outweighed the effects of higher temperature on decomposition rates. Littoral vegetation was a significant source to the soil C pool relative to C sources draining from watersheds. Establishment of vegetation in the shallow water zones of retention ponds is vital to providing a C source to the soil. Thus, the width of littoral shelves containing this vegetation along the perimeter may be increased if C sequestration is a design goal. This assessment establishes that stormwater wet retention ponds can sequester C across different climate zones with generally annual rainfall and lengths of growing season being important general factors for C accumulation. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Reference charts of fetal biometric parameters in 31,476 Brazilian singleton pregnancies.

    PubMed

    Araujo Júnior, Edward; Martins Santana, Eduardo Félix; Martins, Wellington P; Júnior, Julio Elito; Ruano, Rodrigo; Pires, Claudio Rodrigues; Filho, Sebastião Marques Zanforlin

    2014-07-01

    The purpose of this study was to establish reference charts of fetal biometric parameters measured by 2-dimensional sonography in a large Brazilian population. A cross-sectional retrospective study was conducted including 31,476 low-risk singleton pregnancies between 18 and 38 weeks' gestation. The following fetal parameters were measured: biparietal diameter, head circumference, abdominal circumference, femur length, and estimated fetal weight. To assess the correlation between the fetal biometric parameters and gestational age, polynomial regression models were created, with adjustments made by the determination coefficient (R(2)). The means ± SDs of the biparietal diameter, head circumference, abdominal circumference, femur length, and estimated fetal weight measurements at 18 and 38 weeks were 4.2 ± 2.34 and 9.1 ± 4.0 cm, 15.3 ± 7.56 and 32.3 ± 11.75 cm, 13.3 ± 10.42 and 33.4 ± 20.06 cm, 2.8 ± 2.17 and 7.2 ± 3.58 cm, and 256.34 ± 34.03 and 3169.55 ± 416.93 g, respectively. Strong correlations were observed between all fetal biometric parameters and gestational age, best represented by second-degree equations, with R(2) values of 0.95, 0.96, 0.95, 0.95, and 0.95 for biparietal diameter, head circumference, abdominal circumference, femur length, and estimated fetal weight. Fetal biometric parameters were determined for a large Brazilian population, and they may serve as reference values in cases with a high risk of intrauterine growth disorders. © 2014 by the American Institute of Ultrasound in Medicine.

  16. 40 CFR 61.346 - Standards: Individual drain systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Each junction box shall be equipped with a cover and may have a vent pipe. The vent pipe shall be at least 90 cm (3 ft) in length and shall not exceed 10.2 cm (4 in) in diameter. (i) Junction box covers... inspection and maintenance. (ii) One of the following methods shall be used to control emissions from the...

  17. 40 CFR 61.346 - Standards: Individual drain systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Each junction box shall be equipped with a cover and may have a vent pipe. The vent pipe shall be at least 90 cm (3 ft) in length and shall not exceed 10.2 cm (4 in) in diameter. (i) Junction box covers... inspection and maintenance. (ii) One of the following methods shall be used to control emissions from the...

  18. 40 CFR 61.346 - Standards: Individual drain systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Each junction box shall be equipped with a cover and may have a vent pipe. The vent pipe shall be at least 90 cm (3 ft) in length and shall not exceed 10.2 cm (4 in) in diameter. (i) Junction box covers... inspection and maintenance. (ii) One of the following methods shall be used to control emissions from the...

  19. Growth responses of mature loblolly pine to dead wood manipulations

    Treesearch

    Michael D. Ulyshen; Scott Horn; James L. Hanula

    2012-01-01

    Large-scale manipulations of dead wood in mature Pinus taeda L. stands in the southeastern United States included a major one-time input of logs (fivefold increase in log volume) created by felling trees onsite, annual removals of all dead wood above ≥10 cm in diameter and ≥60 cm in length, and a reference in which no...

  20. Root diversity in alpine plants: root length, tensile strength and plant age

    NASA Astrophysics Data System (ADS)

    Pohl, M.; Stroude, R.; Körner, C.; Buttler, A.; Rixen, C.

    2009-04-01

    A high diversity of plant species and functional groups is hypothesised to increase the diversity of root types and their subsequent effects for soil stability. However, even basic data on root characteristics of alpine plants are very scarce. Therefore, we determined important root characteristics of 13 plant species from different functional groups, i.e. grasses, herbs and shrubs. We excavated the whole root systems of 62 plants from a machine-graded ski slope at 2625 m a.s.l. and analysed the rooting depth, the horizontal root extension, root length and diameter. Single roots of plant species were tested for tensile strength. The age of herbs and shrubs was determined by growth-ring analysis. Root characteristics varied considerably between both plant species and functional groups. The rooting depth of different species ranged from 7.2 ± 0.97 cm to 20.5 ± 2.33 cm, but was significantly larger in the herb Geum reptans (70.8 ± 10.75 cm). The woody species Salix breviserrata reached the highest horizontal root extensions (96.8 ± 25.5 cm). Most plants had their longest roots in fine diameter classes (0.5

  1. Uncertainty budgets for liquid waveguide CDOM absorption measurements.

    PubMed

    Lefering, Ina; Röttgers, Rüdiger; Utschig, Christian; McKee, David

    2017-08-01

    Long path length liquid waveguide capillary cell (LWCC) systems using simple spectrometers to determine the spectral absorption by colored dissolved organic matter (CDOM) have previously been shown to have better measurement sensitivity compared to high-end spectrophotometers using 10 cm cuvettes. Information on the magnitude of measurement uncertainties for LWCC systems, however, has remained scarce. Cross-comparison of three different LWCC systems with three different path lengths (50, 100, and 250 cm) and two different cladding materials enabled quantification of measurement precision and accuracy, revealing strong wavelength dependency in both parameters. Stable pumping of the sample through the capillary cell was found to improve measurement precision over measurements made with the sample kept stationary. Results from the 50 and 100 cm LWCC systems, with higher refractive index cladding, showed systematic artifacts including small but unphysical negative offsets and high-frequency spectral perturbations due to limited performance of the salinity correction. In comparison, the newer 250 cm LWCC with lower refractive index cladding returned small positive offsets that may be physically correct. After null correction of measurements at 700 nm, overall agreement of CDOM absorption data at 440 nm was found to be within 5% root mean square percentage error.

  2. A software-based tool for video motion tracking in the surgical skills assessment landscape.

    PubMed

    Ganni, Sandeep; Botden, Sanne M B I; Chmarra, Magdalena; Goossens, Richard H M; Jakimowicz, Jack J

    2018-01-16

    The use of motion tracking has been proved to provide an objective assessment in surgical skills training. Current systems, however, require the use of additional equipment or specialised laparoscopic instruments and cameras to extract the data. The aim of this study was to determine the possibility of using a software-based solution to extract the data. 6 expert and 23 novice participants performed a basic laparoscopic cholecystectomy procedure in the operating room. The recorded videos were analysed using Kinovea 0.8.15 and the following parameters calculated the path length, average instrument movement and number of sudden or extreme movements. The analysed data showed that experts had significantly shorter path length (median 127 cm vs. 187 cm, p = 0.01), smaller average movements (median 0.40 cm vs. 0.32 cm, p = 0.002) and fewer sudden movements (median 14.00 vs. 21.61, p = 0.001) than their novice counterparts. The use of software-based video motion tracking of laparoscopic cholecystectomy is a simple and viable method enabling objective assessment of surgical performance. It provides clear discrimination between expert and novice performance.

  3. Evaluation of an omental pedicle extension technique in the dog.

    PubMed

    Ross, W E; Pardo, A D

    1993-01-01

    A two-step omental pedicle extension technique was performed on 10 dogs. Step 1 of the pedicle extension involved release of the dorsal leaf of the omentum from its pancreatic attachment, whereas step 2 consisted of an inverse L-shaped incision to double the length of the pedicle. The pedicle dimensions were measured and the distance reached when extended toward the hind limb, forelimb, and the muzzle recorded after each stage of the procedure. The vascular patency of the pedicle was determined by intravenous injection of fluorescein dye after the second stage of omental extension. Mean pedicle lengths were 44.5 cm with the first stage of extension and 82.0 cm after full extension. The mean width at the caudal extent of the pedicles after dorsal and full extension was 30.4 cm and 17.2 cm, respectively. Eight of the 10 pedicles were patent after full extension. The fully extended omental pedicles reached and, in most cases, extended beyond the distal extremities and the muzzle. The findings in this study suggest that the canine omentum can be extended to any part of the body without being detached from its vascular supply.

  4. HARP targets pion production cross section and yield measurements: Implications for MiniBooNE neutrino flux

    NASA Astrophysics Data System (ADS)

    Wickremasinghe, Don Athula Abeyarathna

    The prediction of the muon neutrino flux from a 71.0 cm long beryllium target for the MiniBooNE experiment is based on a measured pion production cross section which was taken from a short beryllium target (2.0 cm thick - 5% nuclear interaction length) in the Hadron Production (HARP) experiment at CERN. To verify the extrapolation to our longer target, HARP also measured the pion production from 20.0 cm and 40.0 cm beryllium targets. The measured production yields on targets of 50% and 100% nuclear interaction lengths in the kinematic rage of momentum from 0.75 GeV/c to 6.5 GeV/c and the range of angle from 30 mrad to 210 mrad are presented along with an update of the short target cross sections. The best fitted extended Sanford-Wang (SW) model parameterization for updated short beryllium target positive pion production cross section is presented. Yield measurements for all three targets are also compared with that from the Monte Carlo predictions in the MiniBooNE experiment for different SW parameterization. The comparisons of muon neutrino flux predictions for updated SW model is presented.

  5. Growth, feeding and reproduction of the catfish Eremophilus mutisii (Pisces: Trichomycteridae), from artificial reservoirs in Colombia.

    PubMed

    Pinilla, Gabriel; Abril, Maritza; González, Esperanza

    2006-06-01

    The catfish, Eremophilus mutisii, was cultured under different densities in artificial rainfall reservoirs at Caldas, Boyacá, Colombia. At capture, the average total length of the animals was 10 cm and the weight ranged between 9 and 10 g. These fish were in initial stages of sexual development. After a year in the reservoirs, they had increased in length and weight as follows (densities in parentheses): 5.22 cm and 27.23 g (0.5 individuals/m2); 1.98 cm and 8.79 g (1 individual/m2), and 2.45 cm and 0.82 g (2 individuals/m2). They were at the early stages of sexual maturity, and their condition factor fluctuated between 0.61 and 0.96. They preferably ingested insect larvae that were found in benthic and littoral communities of the reservoirs. The benthos was dominated by ephippia of Daphnia, lumbriculids, and chironomid larvae. The biomass of benthic organisms ranged between 0.1126 and 1.3847 g/m2. In the littoral community aquatic insects were the most important component, especially the hemipterans. The biomass of the littoral fauna ranged between 0.14 and 4.05 g/m2.

  6. Avoidance behavior of juvenile lake sturgeon (Acipenser fulvescens) exposed to Bayluscide 3.2% Granular Sea Lamprey Larvicide

    USGS Publications Warehouse

    Boogaard, Michael A; Rivera, Jane E; Gaikowski, Mark P

    2008-01-01

    Avoidance of juvenile lake sturgeons < 100 mm in length in response to application of the Bayluscide 3.2% Granular Sea Lamprey Larvicide was assessed. Clear plexiglas columns (107 cm in height, 30.5 cm in diameter) to evaluate the potential for the normally bottom-dwelling fishes to move vertically in the water column to avoid niclosamide dissolving from the Bayluscide granules. Vertical migration of lake sturgeons to > 15 cm off the bottom of the column was considered avoidance. Lake sturgeons began displaying avoidance behaviors within 4 to 8 min after the granules were applied and continued for up to 60 min. After 60 min, most or all of the sturgeons were near the surface in the treated columns. In contrast, little movement above the 15-cm mark was observed at any time in any of the control columns. The results of this study are similar to a previous study where juvenile lake sturgeons > 100 mm in length showed the ability to avoid granular Bayluscide. Taken together, we conclude that juvenile lake sturgeons of any size range can detect and avoid granular Bayluscide applications.

  7. Maximum permissible voltage of YBCO coated conductors

    NASA Astrophysics Data System (ADS)

    Wen, J.; Lin, B.; Sheng, J.; Xu, J.; Jin, Z.; Hong, Z.; Wang, D.; Zhou, H.; Shen, X.; Shen, C.

    2014-06-01

    Superconducting fault current limiter (SFCL) could reduce short circuit currents in electrical power system. One of the most important thing in developing SFCL is to find out the maximum permissible voltage of each limiting element. The maximum permissible voltage is defined as the maximum voltage per unit length at which the YBCO coated conductors (CC) do not suffer from critical current (Ic) degradation or burnout. In this research, the time of quenching process is changed and voltage is raised until the Ic degradation or burnout happens. YBCO coated conductors test in the experiment are from American superconductor (AMSC) and Shanghai Jiao Tong University (SJTU). Along with the quenching duration increasing, the maximum permissible voltage of CC decreases. When quenching duration is 100 ms, the maximum permissible of SJTU CC, 12 mm AMSC CC and 4 mm AMSC CC are 0.72 V/cm, 0.52 V/cm and 1.2 V/cm respectively. Based on the results of samples, the whole length of CCs used in the design of a SFCL can be determined.

  8. Temporal artery biopsy size does not matter.

    PubMed

    Kaptanis, Sarantos; Perera, Joanne K; Halkias, Constantine; Caton, Nadine; Alarcon, Lida; Vig, Stella

    2014-12-01

    This study aimed to clarify whether positive temporal artery biopsies had a greater sample length than negative biopsies in temporal arteritis. It has been suggested that biopsy length should be at least 1 cm to improve diagnostic accuracy. A retrospective review of 149 patients who had 151 temporal artery biopsies was conducted. Twenty biopsies were positive (13.3%), 124 negative (82.1%) and seven samples were insufficient (4.6%). There was no clinically significant difference in the mean biopsy size between positive (0.7 cm) and negative samples (0.65 cm) (t-test: p = .43 NS). Ninety-four patients fulfilled all three ACR criteria prior to biopsy (62.3%) and four patients (2.6%) changed ACR score from 2 to 3 after biopsy. Treatment should not be delayed in anticipation of the biopsy or withheld in the case of a negative biopsy if the patient's symptoms improve. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Size-dependent, sex-dependent and seasonal changes in insulin-lige growth-factor-I in the loggerhead sea turtle

    USGS Publications Warehouse

    Crain, D.A.; Bolten, A.B.; Bjorndal, K.A.; Guillette, L.J.; Gross, T.S.

    1995-01-01

    This study examines size-dependent, sex-dependent, and seasonal fluctuations in plasma insulin-like growth factor-I (IGF-I) concentrations in loggerhead sea turtles (Caretta caretta). Loggerhead turtles (n = 158) were captured in shrimp trawler nets during a 12-month survey in Cape Canaveral Channel, Florida. Plasma samples were analyzed using a validated heterologous radioimmunoassay. Large turtles (>75 cm straight-line carapace length) had significantly higher plasma IGF-I concentrations than small turtles (⩽75 cm; P < 0.0001). Plasma IGF-I concentrations did not vary seasonally in small turtles, but large turtles had significantly higher plasma IGF-I concentrations during the spring and summer months (P < 0.005). Within the large turtles, adult males had significantly lower IGF-I concentrations than females and subadult males (P < 0.05). These results and a review of loggerhead turtle natural history suggest that the seasonal fluctuations in plasma IGF-I of adult turtles are due to elevated IGF-I levels in reproductively active female turtles. Further research is needed to examine correlations between reproductive activities and plasma IGF-I concentrations in reptiles.

  10. Calibrator tests of heat flux gauges mounted in SSME blades

    NASA Technical Reports Server (NTRS)

    Liebert, Curt H.

    1989-01-01

    Measurements of heat flux to space shuttle main engine (SSME) turbine blade surfaces are being made in the Lewis heat flux calibration facility. Surface heat flux information is obtained from transient temperature measurements taken at points within the gauge. A 100-kW Vortek arc lamp is used as a source of thermal radiant energy. Thermoplugs, with diameters of about 0.190 cm and lengths varying from about 0.190 to 0.320 cm, are being investigated. The thermoplug is surrounded on all surfaces except the active surface by a pocket of air located in the circular annulus and under the back cover. Since the thermoplug is insulated, it is assumed that heat is conducted in a one-dimensional manner from the hot active surface to the cooler back side of the thermoplug. It is concluded that the miniature plug-type gauge concept is feasible for measurement of blade surface heat flux. It is suggested that it is important to measure heat flux near the hub on the suction surface and at the throat on SSME blades rotating in engines because stress and heat transfer coefficients are high in this region.

  11. Synthesis and Characterization of Pt–Ag Alloy Nanocages with Enhanced Activity and Durability toward Oxygen Reduction

    DOE PAGES

    Yang, Xuan; Roling, Luke T.; Vara, Madeline; ...

    2016-09-23

    Engineering the elemental composition of metal nanocrystals offers an effective strategy for the development of catalysts or electrocatalysts with greatly enhanced activity. Herein, we report the synthesis of Pt–Ag alloy nanocages with an outer edge length of 18 nm and a wall thickness of about 3 nm. Such nanocages with a composition of Pt 19Ag 81 could be readily prepared in one step through the galvanic replacement reaction between Ag nanocubes and a Pt(II) precursor. Here, after 10 000 cycles of potential cycling in the range of 0.60–1.0 V as in an accelerated durability test, the composition of the nanocagesmore » changed to Pt 56Ag 44, together with a specific activity of 1.23 mA cm –2 toward oxygen reduction, which was 3.3 times that of a state-of-the-art commercial Pt/C catalyst (0.37 mA cm –2) prior to durability testing. Density functional theory calculations attributed the increased activity to the stabilization of the transition state for breaking the O–O bond in molecular oxygen. Even after 30 000 cycles of potential cycling, the mass activity of the nanocages only dropped from 0.64 to 0.33 A mg –1 Pt, which was still about two times that of the pristine Pt/C catalyst (0.19 A mg –1 Pt).« less

  12. Synthesis and Characterization of Pt–Ag Alloy Nanocages with Enhanced Activity and Durability toward Oxygen Reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xuan; Roling, Luke T.; Vara, Madeline

    Engineering the elemental composition of metal nanocrystals offers an effective strategy for the development of catalysts or electrocatalysts with greatly enhanced activity. Herein, we report the synthesis of Pt–Ag alloy nanocages with an outer edge length of 18 nm and a wall thickness of about 3 nm. Such nanocages with a composition of Pt 19Ag 81 could be readily prepared in one step through the galvanic replacement reaction between Ag nanocubes and a Pt(II) precursor. Here, after 10 000 cycles of potential cycling in the range of 0.60–1.0 V as in an accelerated durability test, the composition of the nanocagesmore » changed to Pt 56Ag 44, together with a specific activity of 1.23 mA cm –2 toward oxygen reduction, which was 3.3 times that of a state-of-the-art commercial Pt/C catalyst (0.37 mA cm –2) prior to durability testing. Density functional theory calculations attributed the increased activity to the stabilization of the transition state for breaking the O–O bond in molecular oxygen. Even after 30 000 cycles of potential cycling, the mass activity of the nanocages only dropped from 0.64 to 0.33 A mg –1 Pt, which was still about two times that of the pristine Pt/C catalyst (0.19 A mg –1 Pt).« less

  13. Deficits in heel-rise height and achilles tendon elongation occur in patients recovering from an Achilles tendon rupture.

    PubMed

    Silbernagel, Karin Grävare; Steele, Robert; Manal, Kurt

    2012-07-01

    Whether an Achilles tendon rupture is treated surgically or not, complications such as muscle weakness, decrease in heel-rise height, and gait abnormalities persist after injury. The purpose of this study was to evaluate if side-to-side differences in maximal heel-rise height can be explained by differences in Achilles tendon length. Case series; level of evidence, 4. Eight patients (mean [SD] age of 46 [13] years) with acute Achilles tendon rupture and 10 healthy subjects (mean [SD] age of 28 [8] years) were included in the study. Heel-rise height, Achilles tendon length, and patient-reported outcome were measured 3, 6, and 12 months after injury. Achilles tendon length was evaluated using motion analysis and ultrasound imaging. The Achilles tendon length test-retest reliability (intraclass correlation coefficient = 0.97) was excellent. For the healthy subjects, there were no side-to-side differences in tendon length and heel-rise height. Patients with Achilles tendon ruptures had significant differences between the injured and uninjured side for both tendon length (mean [SD] difference, 2.6-3.1 [1.2-1.4] cm, P = .017-.028) and heel-rise height (mean [SD] difference, -4.1 to -6.1 [1.7-1.8] cm, P = .012-.028). There were significant negative correlations (r = -0.943, P = .002, and r = -0.738, P = .037) between the side-to-side difference in heel-rise height and Achilles tendon length at the 6- and 12-month evaluations, respectively. The side-to-side difference found in maximal heel-rise height can be explained by a difference in Achilles tendon length in patients recovering from an Achilles tendon rupture. Minimizing tendon elongation appears to be an important treatment goal when aiming for full return of function.

  14. Relationship between the surrogate anthropometric measures, foot length and chest circumference and birth weight among newborns of Sarlahi, Nepal

    PubMed Central

    Mullany, LC; Darmstadt, GL; Khatry, SK; LeClerq, SC; Tielsch, JM

    2008-01-01

    Background Classification of infants into low birth weight (LBW, <2500 g) or very low birth weight (VLBW, <2000 g) categories is a crucial step in targeting interventions to high-risk infants. Objective To compare the validity of chest circumference and foot length as surrogate anthropometric measures for the identification of LBW and VLBW infants. Subjects and setting Newborn infants (n = 1640) born between March and June 2004 in 30 Village Development Committees of Sarlahi district, Nepal. Design Chest circumference, foot length and weight (SECA 727, precise to 2 g) of newborns were measured within 72 h after birth. The sensitivity, specificity and predictive values for a range of cutoff points of the anthropometric measures were estimated using the digital scale measurements as the gold standard. Results Among LBW infants (469/1640, 28.6%), chest circumference measures <30.3 cm were 91% sensitive and 83% specific. Similar levels of sensitivity for foot length were achieved only with considerable loss of specificity (<45%). Foot length measurements <6.9 cm were 88% sensitive and 86% specific for the identification of VLBW infants. Conclusion Chest circumference was superior to foot length in classification of infants into birth weight categories. For the identification of VLBW infants, foot length performed well, and may be preferable to chest circumference, as the former measure does not require removal of infant swaddling clothes. In the absence of more precise direct measures of birth weight, chest circumference is recommended over foot length for the identification of LBW infants. Sponsorship The National Institute of Child Health and Human Development; the Saving Newborn Lives Initiative, Save the Children – US and the Office of Heath and Nutrition, United States Agency for International Development (see Acknowledgements). PMID:16885929

  15. Effect of Channel Thickness, Annealing Temperature and Channel Length on Nanoscale Ga2O3-In2O3-ZnO Thin Film Transistor Performance.

    PubMed

    Kumaresan, Yogeenth; Pak, Yusin; Lim, Namsoo; Lee, Ryeri; Song, Hui; Kim, Tae Heon; Choi, Boran; Jung, Gun Young

    2016-06-01

    We demonstrated the effect of active layer (channel) thickness and annealing temperature on the electrical performances of Ga2O3-In2O3-ZnO (GIZO) thin film transistor (TFT) having nanoscale channel width (W/L: 500 nm/100 μm). We found that the electron carrier concentration of the channel was decreased significantly with increasing the annealing temperature (100 degrees C to 300 degrees C). Accordingly, the threshold voltage (V(T)) was shifted towards positive voltage (-12.2 V to 10.8 V). In case of channel thickness, the V(T) was shifted towards negative voltage with increasing the channel thickness. The device with channel thickness of 90 nm annealed at 200 degrees C revealed the best device performances in terms of mobility (10.86 cm2/Vs) and V(T) (0.8 V). The effect of channel length was also studied, in which the channel width, thickness and annealing temperature were kept constant such as 500 nm, 90 nm and 200 degrees C, respectively. The channel length influenced the on-current level significantly with small variation of V(T), resulting in lower value of on/off current ratio with increasing the channel length. The device with channel length of 0.5 μm showed enhanced on/off current ratio of 10(6) with minimum V(T) of 0.26 V.

  16. Full-length U-xPu-10Zr (x = 0, 8, 19 wt.%) fast reactor fuel test in FFTF

    NASA Astrophysics Data System (ADS)

    Porter, D. L.; Tsai, Hanchung

    2012-08-01

    The Integral Fast Reactor-1 (IFR-1) experiment performed in the Fast Flux Test Facility (FFTF) was the only U-Pu-10Zr (Pu-0, 8 and 19 wt.%) metallic fast reactor test with commercial-length (91.4-cm active fuel-column length) conducted to date. With few remaining test reactors, there is little opportunity for performing another test with a long active fuel column. The assembly was irradiated to the goal burnup of 10 at.%. The beginning-of-life (BOL) peak cladding temperature of the hottest pin was 608 °C, cooling to 522 °C at end-of-life (EOL). Selected fuel pins were examined non-destructively using neutron radiography, precision axial gamma scanning, and both laser and spiral contact cladding profilometry. Destructive exams included plenum gas pressure, volume, and gas composition determinations on a number of pins followed by optical metallography, electron probe microanalysis (EPMA), and alpha and beta-gamma autoradiography on a single U-19Pu-10Zr pin. The post-irradiation examinations (PIEs) showed very few differences compared to the short-pin (34.3-cm fuel column) testing performed on fuels of similar composition in Experimental Breeder Reactor-II (EBR-II). The fuel column grew axially slightly less than observed in the short pins, but with the same pattern of decreasing growth with increasing Pu content. There was a difference in the fuel-cladding chemical interaction (FCCI) in that the maximum cladding penetration by interdiffusion with fuel/fission products did not occur at the top of the fuel column where the cladding temperature is highest, as observed in EBR-II tests. Instead, the more exaggerated fission-rate profile of the FFTF pins resulted in a peak FCCI at ˜0.7 X/L axial location along the fuel column. This resulted from a higher production of rare-earth fission products at this location and a higher ΔT between fuel center and cladding than at core center, together providing more rare earths at the cladding and more FCCI. This behavior could actually help extend the life of a fuel pin in a "long pin" reactor design to a higher peak fuel burnup.

  17. [Micropterus salmoides (Pisces: Centrarchidae) reproduction in the Gustavo Diaz Ordaz reservoir, Sinaloa, México].

    PubMed

    Beltrán Alvarez, Rigoberto; Sánchez Palacios, Jesús; Ramírez Lozano, Juan Pedro; Ortega Salas, Adolfo-Armando

    2013-09-01

    Micropterus salmoides is an important fish species for sport fishing activities, condition that has promoted its introduction to different reservoirs in Mexico and worldwide. With the aim to improve its fisheries management, this research dealt with some reproductive aspects of this species in the Gustavo Diaz Ordaz reservoir, where it was studied from August 2008 through March 2011. To this end, we obtained 938 specimens, with gillnets of different sizes, to determine their total length (Lt, in cm), weight (Pt, in g), sex, gonadosomatic index, condition factor, fecundity and size at first maturity. Lt and Pt ranged from 15.9 to 63 cm (37.4 +/- 78.0) and 57 to 4431 g (731.7 +/- 619.0), respectively. The Pt-Lt relationship showed a positive allometric growth, with no significant difference between males and females (F = 0.9955, p = 0.3187). The male: female ratio obtained was 1:0.83. Mass spawning lasted from December to April. Size at first maturity was 33.7 cm and average fecundity was 32294 +/- 12878.7 oocytes/female. The gonadosomatic index was low from May through November, and increased between January and March. The condition factor was high before the spawning season and decreased after the reproductive period. We recommend a fishing ban from January to March, and to allow the capture size between 33 and 40 cm.

  18. Plasma Deposited SiO2 for Planar Self-Aligned Gate Metal-Insulator-Semiconductor Field Effect Transistors on Semi-Insulating InP

    NASA Technical Reports Server (NTRS)

    Tabory, Charles N.; Young, Paul G.; Smith, Edwyn D.; Alterovitz, Samuel A.

    1994-01-01

    Metal-insulator-semiconductor (MIS) field effect transistors were fabricated on InP substrates using a planar self-aligned gate process. A 700-1000 A gate insulator of Si02 doped with phosphorus was deposited by a direct plasma enhanced chemical vapor deposition at 400 mTorr, 275 C, 5 W, and power density of 8.5 MW/sq cm. High frequency capacitance-voltage measurements were taken on MIS capacitors which have been subjected to a 700 C anneal and an interface state density of lxl0(exp 11)/eV/cq cm was found. Current-voltage measurements of the capacitors show a breakdown voltage of 107 V/cm and a insulator resistivity of 10(exp 14) omega cm. Transistors were fabricated on semi-insulating InP using a standard planar self-aligned gate process in which the gate insulator was subjected to an ion implantation activation anneal of 700 C. MIS field effect transistors gave a maximum extrinsic transconductance of 23 mS/mm for a gate length of 3 microns. The drain current drift saturated at 87.5% of the initial current, while reaching to within 1% of the saturated value after only 1x10(exp 3). This is the first reported viable planar InP self-aligned gate transistor process reported to date.

  19. Overview of the Conceptual Design of the Future VENUS Neutron Imaging Beam Line at the Spallation Neutron Source

    NASA Astrophysics Data System (ADS)

    Bilheux, Hassina; Herwig, Ken; Keener, Scott; Davis, Larry

    VENUS (Versatile Neutron Imaging Beam line at the Spallation Neutron Source) will be a world-class neutron-imaging instrument that will uniquely utilize the Spallation Neutron Source (SNS) time-of-flight (TOF) capabilities to measure and characterize objects across several length scales (mm to μm). When completed, VENUS will provide academia, industry and government laboratories with the opportunity to advance scientific research in areas such as energy, materials, additive manufacturing, geosciences, transportation, engineering, plant physiology, biology, etc. It is anticipated that a good portion of the VENUS user community will have a strong engineering/industrial research focus. Installed at Beam line 10 (BL10), VENUS will be a 25-m neutron imaging facility with the capability to fully illuminate (i.e., umbra illumination) a 20 cm x 20 cm detector area. The design allows for a 28 cm x 28 cm field of view when using the penumbra to 80% of the full illumination flux. A sample position at 20 m will be implemented for magnification measurements. The optical components are comprised of a series of selected apertures, T0 and bandwidth choppers, beam scrapers, a fast shutter to limit sample activation, and flight tubes filled with Helium. Techniques such as energy selective, Bragg edge and epithermal imaging will be available at VENUS.

  20. Characterization of copper and nichrome wires for safety fuse

    NASA Astrophysics Data System (ADS)

    Murdani, E.

    2016-11-01

    Fuse is an important component of an electrical circuit to limiting the current through the electrical circuit for electrical equipment safety. Safety fuses are made of a conductor such as copper and nichrome wires. The aim of this research was to determine the maximum current that can flow in the conductor wires (copper and nichrome). In the experiment used copper and nichrome wires by varying the length of wires (0.2 cm to 20 cm) and diameter of wires (0.1, 0.2, 0.3, 0.4 and 0.5) mm until maximum current reached that marked by melted or broken wire. From this experiment, it will be obtained the dependences data of maximum current to the length and diameter of wires. All data are plotted and it's known as a standard curve. The standard curve will provide an alternative choice of replacing fuse wire according to the maximum current requirement, including the wire type (copper and nichrome wires) and wire dimensions (length and diameter of wire).

  1. Experimental Study of Fillets to Reduce Corner Effects in an Oblique Shock-Wave/Boundary Layer Interaction

    NASA Technical Reports Server (NTRS)

    Hirt, Stefanie M.

    2015-01-01

    A test was conducted in the 15 cm x 15 cm supersonic wind tunnel at NASA Glenn Research Center that focused on corner effects of an oblique shock-wave/boundary-layer interaction. In an attempt to control the interaction in the corner region, eight corner fillet configurations were tested. Three parameters were considered for the fillet configurations: the radius, the fillet length, and the taper length from the square corner to the fillet radius. Fillets effectively reduced the boundary-layer thickness in the corner; however, there was an associated penalty in the form of increased boundary-layer thickness at the tunnel centerline. Larger fillet radii caused greater reductions in boundary-layer thickness along the corner bisector. To a lesser, but measureable, extent, shorter fillet lengths resulted in thinner corner boundary layers. Overall, of the configurations tested, the largest radius resulted in the best combination of control in the corner, evidenced by a reduction in boundary-layer thickness, coupled with minimal impacts at the tunnel centerline.

  2. Penile suspensory ligament division for penile augmentation: indications and results.

    PubMed

    Li, Chi-Ying; Kayes, Oliver; Kell, Phillip D; Christopher, Nim; Minhas, Suks; Ralph, David J

    2006-04-01

    This study assessed the management of patients requesting penile length enhancement by division of the penile suspensory ligament. From September 1998 to January 2005, 42 patients with a variety of etiologies were included; all underwent division of the penile suspensory ligament. The outcome was assessed objectively based on increase in flaccid stretched penile length (SPL) and subjectively using the rates of patient satisfaction. The mean increase in SPL was 1.3+/-0.9 cm (range, -1 to +3 cm), with the addition of a silicone spacer placed between the pubis and penis giving a better outcome (p<0.05). The overall patient satisfaction rate was 35% but lower in the group with penile dysmorphic disorder at 27%. Division of the penile suspensory ligament or other augmentation techniques may increase penile length but usually not to a degree that satisfies the patient. Men with penile dysmorphic disorder often have unrealistic expectations regarding the outcome of surgical intervention and should be encouraged to seek psychological help primarily, with surgery reserved as the last resort.

  3. East Butte: A volcanic dome of the Eastern Snake River Plain, Idaho

    NASA Technical Reports Server (NTRS)

    Bretches, J. E.; King, J. S.

    1984-01-01

    Preliminary mapping shows East Butte to be a single, large cumulo-dome composed dominantly of rhyolite which can be classified into three main groups based on color and structure. The rhyolite of East Butte is aphanitic with phenocrysts of sanidine and quartz which vary from 1 to 5 mm in length. Vesicular reddish black inclusions of basalt up to 10 cm in length, found in all varieties of the East Butte rhyolites are believed to have originated from fragmentation of the basalt walls of the conduit by rhyolitic magma as it was emplaced. Most of the inclusions contain plagioclase phenocrysts. These phenocrysts measure up to 1 to 2 cm in length and have a typical euhedral, tabular habit. A 250-m diameter depression which has the appearance of a crater is located at the top of East Butte. Evidence supporting the fact that the depression is a crater is displayed by three small (3 to 5 m in height) mounds of massive rhyolite which border the depression.

  4. Diffusion lengths in irradiated N/P InP-on-Si solar cells

    NASA Technical Reports Server (NTRS)

    Wojtczuk, Steven; Colerico, Claudia; Summers, Geoffrey P.; Walters, Robert J.; Burke, Edward A.

    1995-01-01

    Indium phosphide (InP) solar cells are being made on silicon (Si) wafers (InP/Si) to take advantage of both the radiation-hardness properties of the InP solar cell and the light weight and low cost of Si wafers compared to InP or germanium (Ge) wafers. The InP/Si cell application is for long duration and/or high radiation orbit space missions. InP/Si cells have higher absolute efficiency after a high radiation dose than gallium arsenide (GaAs) or silicon (Si) solar cells. In this work, base electron diffusion lengths in the N/P cell are extracted from measured AM0 short-circuit photocurrent at various irradiation levels out to an equivalent 1 MeV fluence of 1017 1 MeV electrons/sq cm for a 1 sq cm 12% BOL InP/Si cell. These values are then checked for consistency by comparing measured Voc data with a theoretical Voc model that includes a dark current term that depends on the extracted diffusion lengths.

  5. Twisted, multifilament Nb3Sn superconductive ribbon

    NASA Technical Reports Server (NTRS)

    Coles, W. D.

    1972-01-01

    An experimental study of superconductor stabilization has resulted in the successful application of the concepts of filamentary structure and conductor twist to Nb3Sn ribbon. The Nb3Sn is formed in parallel, helical paths, which are continuous around the ribbon. Short lengths (12-18cm) of 1.27 cm wide superconductive ribbon were produced. The filamentary and twist characteristics are incorporated in the ribbon by means of an inert mask formed on the ribbon surface early in the fabrication process. Diffusion reaction of the niobium and tin is prevented at the filament boundaries. Described are the conductor methods of fabrication, and test results obtained. The technology required to adapt the processes for the production of long lengths of ribbon is available.

  6. Scavenging energy from human motion with tubular dielectric polymer

    NASA Astrophysics Data System (ADS)

    Jean-Mistral, Claire; Basrour, Skandar

    2010-04-01

    Scavenging energy from human motion is a challenge to supply low consumption systems for sport or medical applications. A promising solution is to use electroactive polymers and especially dielectric polymers to scavenge mechanical energy during walk. In this paper, we present a tubular dielectric generator which is the first step toward an integration of these structures into textiles. For a 10cm length and under a strain of 100%, the structure is able to scavenge 1.5μJ for a poling voltage of 200V and up to 40μJ for a poling voltage of 1000V. A 30cm length structure is finally compared to our previous planar structure, and the power management module for those structures is discussed.

  7. Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research

    NASA Astrophysics Data System (ADS)

    Bergeron, Mélanie; Cadorette, Jules; Tétrault, Marc-André; Beaudoin, Jean-François; Leroux, Jean-Daniel; Fontaine, Réjean; Lecomte, Roger

    2014-02-01

    The LabPET is an avalanche photodiode (APD) based digital PET scanner with quasi-individual detector read-out and highly parallel electronic architecture for high-performance in vivo molecular imaging of small animals. The scanner is based on LYSO and LGSO scintillation crystals (2×2×12/14 mm3), assembled side-by-side in phoswich pairs read out by an APD. High spatial resolution is achieved through the individual and independent read-out of an individual APD detector for recording impinging annihilation photons. The LabPET exists in three versions, LabPET4 (3.75 cm axial length), LabPET8 (7.5 cm axial length) and LabPET12 (11.4 cm axial length). This paper focuses on the systematic characterization of the three LabPET versions using two different energy window settings to implement a high-efficiency mode (250-650 keV) and a high-resolution mode (350-650 keV) in the most suitable operating conditions. Prior to measurements, a global timing alignment of the scanners and optimization of the APD operating bias have been carried out. Characteristics such as spatial resolution, absolute sensitivity, count rate performance and image quality have been thoroughly investigated following the NEMA NU 4-2008 protocol. Phantom and small animal images were acquired to assess the scanners' suitability for the most demanding imaging tasks in preclinical biomedical research. The three systems achieve the same radial FBP spatial resolution at 5 mm from the field-of-view center: 1.65/3.40 mm (FWHM/FWTM) for an energy threshold of 250 keV and 1.51/2.97 mm for an energy threshold of 350 keV. The absolute sensitivity for an energy window of 250-650 keV is 1.4%/2.6%/4.3% for LabPET4/8/12, respectively. The best count rate performance peaking at 362 kcps is achieved by the LabPET12 with an energy window of 250-650 keV and a mouse phantom (2.5 cm diameter) at an activity of 2.4 MBq ml-1. With the same phantom, the scatter fraction for all scanners is about 17% for an energy threshold of 250 keV and 10% for an energy threshold of 350 keV. The results obtained with two energy window settings confirm the relevance of high-efficiency and high-resolution operating modes to take full advantage of the imaging capabilities of the LabPET scanners for molecular imaging applications.

  8. Severe perineal lacerations in nulliparous women and episiotomy type.

    PubMed

    Aytan, Hakan; Tapisiz, Omer L; Tuncay, Gorkem; Avsar, Filiz A

    2005-07-01

    To determine the patient-related factors associated with severe perineal lacerations in nulliparous women and to evaluate the effect of episiotomy type on the risk of severe perineal tears. In all, 400 nulliparous women admitted in labor between June and December 2001 were prospectively enrolled. Maternal height, perineal length, fetal birth weight, fetal head circumference, and severe perineal lacerations (third and fourth degrees) were recorded. The rate of severe perineal lacerations was 2% (8/400); 3% with midline, 1% with mediolateral groups. In patients with severe lacerations, perineal length was significantly (p < 0.001) shorter and the head circumference of their babies in the midline significantly (p < 0.05) greater than normal, and birth weights were also significantly (p < 0.05) greater in the mediolateral group. A cut-off value for perineal length of 3.05 cm was found for severe lacerations in the midline group. If episiotomy is to be performed, it must be borne in mind that patients with a perineal length of < or = 3 cm have an elevated risk of severe perineal lacerations, and if clinical or ultrasound examination suggests that the fetal head is large, mediolateral episiotomy may be preferred. Otherwise, midline episiotomy must be considered.

  9. Using specific length amplified fragment sequencing to construct the high-density genetic map for Vitis (Vitis vinifera L. × Vitis amurensis Rupr.)

    PubMed Central

    Guo, Yinshan; Shi, Guangli; Liu, Zhendong; Zhao, Yuhui; Yang, Xiaoxu; Zhu, Junchi; Li, Kun; Guo, Xiuwu

    2015-01-01

    In this study, 149 F1 plants from the interspecific cross between ‘Red Globe’ (Vitis vinifera L.) and ‘Shuangyou’ (Vitis amurensis Rupr.) and the parent were used to construct a molecular genetic linkage map by using the specific length amplified fragment sequencing technique. DNA sequencing generated 41.282 Gb data consisting of 206,411,693 paired-end reads. The average sequencing depths were 68.35 for ‘Red Globe,’ 63.65 for ‘Shuangyou,’ and 8.01 for each progeny. In all, 115,629 high-quality specific length amplified fragments were detected, of which 42,279 were polymorphic. The genetic map was constructed using 7,199 of these polymorphic markers. These polymorphic markers were assigned to 19 linkage groups; the total length of the map was 1929.13 cm, with an average distance of 0.28 cm between each maker. To our knowledge, the genetic maps constructed in this study contain the largest number of molecular markers. These high-density genetic maps might form the basis for the fine quantitative trait loci mapping and molecular-assisted breeding of grape. PMID:26089826

  10. DNA electrophoresis in agarose gels: effects of field and gel concentration on the exponential dependence of reciprocal mobility on DNA length.

    PubMed

    Rill, Randolph L; Beheshti, Afshin; Van Winkle, David H

    2002-08-01

    Electrophoretic mobilities of DNA molecules ranging in length from 200 to 48 502 base pairs (bp) were measured in agarose gels with concentrations T = 0.5% to 1.3% at electric fields from E = 0.71 to 5.0 V/cm. This broad data set determines a range of conditions over which the new interpolation equation nu(L) = (beta+alpha(1+exp(-L/gamma))(-1) can be used to relate mobility to length with high accuracy. Mobility data were fit with chi(2) > 0.999 for all gel concentrations and fields ranging from 2.5 to 5 V/cm, and for lower fields at low gel concentrations. Analyses using so-called reptation plots (Rousseau, J., Drouin, G., Slater, G. W., Phys. Rev. Lett. 1997, 79, 1945-1948) indicate that this simple exponential relation is obeyed well when there is a smooth transition from the Ogston sieving regime to the reptation regime with increasing DNA length. Deviations from this equation occur when DNA migration is hindered, apparently by entropic-trapping, which is favored at low fields and high gel concentrations in the ranges examined.

  11. A case of 45,X/47,XXX mosaic Turner syndrome with limb length discrepancy.

    PubMed

    Hishimura-Yonemaru, Nozomi; Okuhara, Koji; Takahashi, Nobuhiro; Tonoki, Hidefumi; Iizuka, Susumu; Tajima, Toshihiro

    2017-01-01

    Patients with Turner syndrome (TS) frequently show short stature and skeletal deformities, such as kyphosis and scoliosis. However, to the best of our knowledge, limb length discrepancy (LLD) has not yet been reported in patients with TS. The case of a 12-yr-old girl with 45,X/47,XXX mosaic TS showing LLD is herein presented. She was on GH therapy for short stature and was noted to have scoliosis in the standing position at a regular examination; however, the scoliosis became less evident in the supine position, which is indicative of LLD. The length of the left leg was 5.0 cm shorter than that of the right leg when measured. She was referred to orthopedics and underwent right distal femoral and right proximal tibial staple epiphysiodesis to shorten the abnormally long limb at 10 yr 6 mo of age. One year after the operation, the LLD decreased from 5.0 to 1.5 cm. During this period, GH was continued. LLD is a rare complication in TS, but when patients with TS show scoliosis in the standing position, re-evaluation for scoliosis in the supine position should be performed and the lengths of both legs should be measured.

  12. Asymmetry in the Discrimination of Length During Spatial Learning

    PubMed Central

    2013-01-01

    The ability of rats to solve a discrimination between two objects that differ in length was investigated in five experiments. Using a rectangular swimming pool, Experiment 1 revealed it is easier to locate a submerged platform when it is near the center of a long rather than a short wall. For Experiments 2–4, the objects were black or white panels pasted onto the gray walls of a square pool, with two long panels pasted to two opposing walls and two short panels pasted to the remaining walls. The platform was easier to locate when it was placed near the middle of a long rather than a short panel. This effect was found when the long panels were twice (Experiments 2–4) or four times the length of the short panels (Experiment 4). Experiment 5 demonstrated that rats can solve a discrimination between panels of length 15 and 45 cm more readily than when they are 70 and 100 cm. The results are consistent with the claim that generalization gradients based on stimulus magnitude are steeper for stimuli that are weaker rather than stronger than the stimulus used for the original training. PMID:23668184

  13. Progress in long scale length laser plasma interactions

    NASA Astrophysics Data System (ADS)

    Glenzer, S. H.; Arnold, P.; Bardsley, G.; Berger, R. L.; Bonanno, G.; Borger, T.; Bower, D. E.; Bowers, M.; Bryant, R.; Buckman, S.; Burkhart, S. C.; Campbell, K.; Chrisp, M. P.; Cohen, B. I.; Constantin, C.; Cooper, F.; Cox, J.; Dewald, E.; Divol, L.; Dixit, S.; Duncan, J.; Eder, D.; Edwards, J.; Erbert, G.; Felker, B.; Fornes, J.; Frieders, G.; Froula, D. H.; Gardner, S. D.; Gates, C.; Gonzalez, M.; Grace, S.; Gregori, G.; Greenwood, A.; Griffith, R.; Hall, T.; Hammel, B. A.; Haynam, C.; Heestand, G.; Henesian, M.; Hermes, G.; Hinkel, D.; Holder, J.; Holdner, F.; Holtmeier, G.; Hsing, W.; Huber, S.; James, T.; Johnson, S.; Jones, O. S.; Kalantar, D.; Kamperschroer, J. H.; Kauffman, R.; Kelleher, T.; Knight, J.; Kirkwood, R. K.; Kruer, W. L.; Labiak, W.; Landen, O. L.; Langdon, A. B.; Langer, S.; Latray, D.; Lee, A.; Lee, F. D.; Lund, D.; MacGowan, B.; Marshall, S.; McBride, J.; McCarville, T.; McGrew, L.; Mackinnon, A. J.; Mahavandi, S.; Manes, K.; Marshall, C.; Menapace, J.; Mertens, E.; Meezan, N.; Miller, G.; Montelongo, S.; Moody, J. D.; Moses, E.; Munro, D.; Murray, J.; Neumann, J.; Newton, M.; Ng, E.; Niemann, C.; Nikitin, A.; Opsahl, P.; Padilla, E.; Parham, T.; Parrish, G.; Petty, C.; Polk, M.; Powell, C.; Reinbachs, I.; Rekow, V.; Rinnert, R.; Riordan, B.; Rhodes, M.; Roberts, V.; Robey, H.; Ross, G.; Sailors, S.; Saunders, R.; Schmitt, M.; Schneider, M. B.; Shiromizu, S.; Spaeth, M.; Stephens, A.; Still, B.; Suter, L. J.; Tietbohl, G.; Tobin, M.; Tuck, J.; Van Wonterghem, B. M.; Vidal, R.; Voloshin, D.; Wallace, R.; Wegner, P.; Whitman, P.; Williams, E. A.; Williams, K.; Winward, K.; Work, K.; Young, B.; Young, P. E.; Zapata, P.; Bahr, R. E.; Seka, W.; Fernandez, J.; Montgomery, D.; Rose, H.

    2004-12-01

    The first experiments on the National Ignition Facility (NIF) have employed the first four beams to measure propagation and laser backscattering losses in large ignition-size plasmas. Gas-filled targets between 2 and 7 mm length have been heated from one side by overlapping the focal spots of the four beams from one quad operated at 351 nm (3ω) with a total intensity of 2 × 1015 W cm-2. The targets were filled with 1 atm of CO2 producing up to 7 mm long homogeneously heated plasmas with densities of ne = 6 × 1020 cm-3 and temperatures of Te = 2 keV. The high energy in an NIF quad of beams of 16 kJ, illuminating the target from one direction, creates unique conditions for the study of laser-plasma interactions at scale lengths not previously accessible. The propagation through the large-scale plasma was measured with a gated x-ray imager that was filtered for 3.5 keV x-rays. These data indicate that the beams interact with the full length of this ignition-scale plasma during the last ~1 ns of the experiment. During that time, the full aperture measurements of the stimulated Brillouin scattering and stimulated Raman scattering show scattering into the four focusing lenses of 3% for the smallest length (~2 mm), increasing to 10-12% for ~7 mm. These results demonstrate the NIF experimental capabilities and further provide a benchmark for three-dimensional modelling of the laser-plasma interactions at ignition-size scale lengths.

  14. Infant head circumference growth is saltatory and coupled to length growth.

    PubMed

    Lampl, Michelle; Johnson, Michael L

    2011-05-01

    Rapid growth rates of head circumference and body size during infancy have been reported to predict developmental pathologies that emerge during childhood. This study investigated whether growth in head circumference was concordant with growth in body length. Forty infants (16 males) were followed between the ages of 2 days and 21 months for durations ranging from 4 to 21 months (2616 measurements). Longitudinal anthropometric measurements were assessed weekly (n=12), semi-weekly (n=24) and daily (n=4) during home visits. Individual head circumference growth was investigated for the presence of saltatory patterns. Coincident analysis tested the null hypothesis that head growth was randomly coupled to length growth. Head circumference growth during infancy is saltatory (p<0.05), characterized by median increments of 0.20 cm (95% confidence interval, 0.10-0.30 cm) in 24-h, separated by intervals of no growth ranging from 1 to 21 days. Daily assessments identified that head growth saltations were coupled to length growth saltations within a median time frame of 2 days (interquartile 0-4, range 1-8 days). Assessed at semi-weekly and weekly intervals, an average 82% (SD 0.13) of head growth saltations was non-randomly concordant with length growth (p≤0.006). Normal infant head circumference grows by intermittent, episodic saltations that are temporally coupled to growth in total body length by a process of integrated physiology that remains to be described. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Impact of fetal gender on the labor curve.

    PubMed

    Cahill, Alison G; Roehl, Kimberly A; Odibo, Anthony O; Zhao, Qiuhong; Macones, George A

    2012-04-01

    We sought to estimate the association between fetal gender and first-stage labor curve at term. Within a large, retrospective cohort study of consecutive, singleton term labor patients who delivered in the second stage, we compared the active phase of first-stage labor by fetal gender. The primary outcome was length of active stage 1. Interval-censored regression was used to estimate the effect of fetal gender on the duration of active first stage (4-10 cm) and was adjusted for relevant covariates. Of 2400 women, 2373 women had complete labor information and were available for this analysis. Male gender was associated with both a statistically significantly longer active first stage of labor (4.6 vs 4.0 hours; P = .002) and stratified analyses by parity and labor type. Male fetuses are associated with longer active phase of the first stage of labor and, specifically, may need to be considered in the setting of arrest diagnoses. Copyright © 2012 Mosby, Inc. All rights reserved.

  16. Comparison of GEANT4 Physics Models with Measured Beta Particle Data in Aluminum using a Strontium-90 Source

    NASA Astrophysics Data System (ADS)

    Everett, Samantha

    2010-10-01

    A transmission curve experiment was carried out to measure the range of beta particles in aluminum in the health physics laboratory located on the campus of Texas Southern University. The transmission count rate through aluminum for varying radiation lengths was measured using beta particles emitted from a low activity (˜1 μCi) Sr-90 source. The count rate intensity was recorded using a Geiger Mueller tube (SGC N210/BNC) with an active volume of 61 cm^3 within a systematic detection accuracy of a few percent. We compared these data with a realistic simulation of the experimental setup using the Geant4 Monte Carlo toolkit (version 9.3). The purpose of this study was to benchmark our Monte Carlo for future experiments as part of a more comprehensive research program. Transmission curves were simulated based on the standard and low-energy electromagnetic physics models, and using the radioactive decay module for the electrons primary energy distribution. To ensure the validity of our measurements, linear extrapolation techniques were employed to determine the in-medium beta particle range from the measured data and was found to be 1.87 g/cm^2 (˜0.693 cm), in agreement with literature values. We found that the general shape of the measured data and simulated curves were comparable; however, a discrepancy in the relative count rates was observed. The origin of this disagreement is still under investigation.

  17. Electron beam extraction on plasma cathode electron sources system

    NASA Astrophysics Data System (ADS)

    Purwadi, Agus; Taufik, M., Lely Susita R.; Suprapto, Saefurrochman, H., Anjar A.; Wibowo, Kurnia; Aziz, Ihwanul; Siswanto, Bambang

    2017-03-01

    ELECTRON BEAM EXTRACTION ON PLASMA CATHODE ELECTRON SOURCES SYSTEM. The electron beam extraction through window of Plasma Generator Chamber (PGC) for Pulsed Electron Irradiator (PEI) device and simulation of plasma potential has been studied. Plasma electron beam is extracted to acceleration region for enlarging their power by the external accelerating high voltage (Vext) and then it is passed foil window of the PEI for being irradiated to any target (atmospheric pressure). Electron beam extraction from plasma surface must be able to overcome potential barrier at the extraction window region which is shown by estimate simulation (Opera program) based on data of plasma surface potential of 150 V with Ueks values are varied by 150 kV, 175 kV and 200 kV respectively. PGC is made of 304 stainless steel with cylindrical shape in 30 cm of diameter, 90 cm length, electrons extraction window as many as 975 holes on the area of (15 × 65) cm2 with extraction hole cell in 0.3 mm of radius each other, an cylindrical shape IEP chamber is made of 304 stainless steel in 70 cm diameter and 30 cm length. The research result shown that the acquisition of electron beam extraction current depends on plasma parameters (electron density ne, temperature Te), accelerating high voltage Vext, the value of discharge parameter G, anode area Sa, electron extraction window area Se and extraction efficiency value α.

  18. Effects of biological and technical factors on brain and muscle cholinesterases in Nile tilapia, Oreochromis niloticus: implications for biomonitoring neurotoxic contaminations.

    PubMed

    Pathiratne, A; Chandrasekera, L W H U; De Seram, P K C

    2008-02-01

    Influence of body length, body weight, gender, sexual maturity, and tissue storage on brain and muscle cholinesterases (ChE) in Nile tilapia was evaluated considering its potential use in biomonitoring neurotoxic contaminations in tropical environments. Results show that ChE activities in both tissues decreased significantly with increased total length (4-24.5 cm) or body weight (1-186 g) of the fish and the relationships were curvilinear. Comparisons of the slopes and elevations of the regression lines of the logarithmic ChE and body size relationships of males with those of females indicated that gender had no significant effect on the body size-specific ChE activities. Response of the ChE of sexually mature males to chlorpyrifos exposure was similar to that of females. Gonadal maturity stage of this fish does not seem to influence ChE activities. Storage of tissues at -80 degrees C for 28 days had no significant effect on ChE activities in the control fish and the fish exposed to carbofuran. However, a partial reactivation of brain ChE activities was observed in the fish exposed to carbosulfan after 28 days of storage. The results emphasize the importance of consideration of body size of the fish and storage time of the tissues in order to formulate accurate conclusions about the neurotoxic chemical exposure when ChE of the fish is used in biomonitoring programs.

  19. Optimization of Soft Tissue Management, Spacer Design, and Grafting Strategies for Large Segmental Bone Defects using the Chronic Caprine Tibial Defect Model

    DTIC Science & Technology

    2016-12-01

    gastrocnemius muscles. 4. Place an interlocking intramedullary nail using a custom spacer to maintain 5-cm defect length. 5. Place a pre-molded 5 cm long x...2 cm diameter PMMA spacer around the nail in the defect. 6. Irrigate the wound with normal (0.9 %) saline and close the wound. The Treatment...PMMA spacer using a “bomb bay door opening”. 4. Remove the spacer without damaging the membrane or nail . 5. Collect appropriate IM samples as

  20. Multi-Disciplinary Research for High Energy Chemical Lasers, Closed-Cycle ElectricOIL Technology

    DTIC Science & Technology

    2007-10-31

    flow iodine from one reservoir and trap it in another. The principal advantage of the hybrid EOIL system is trading a small fixed mass in electrical...rapidly modulate the production of the 02(a) which have motivated investigations into methods to produce significant amounts of 02(a) using flowing...RF power is used for the production of ChC’Ag) in a cylindrical tube (R=2.54 cm and length of 10 cm) with a volume of 200 cm3 at 4.2 torr of pure O2

Top