Sample records for cm diameter cylindrical

  1. Operating characteristics of tube-current-modulation techniques when scanning simple-shaped phantoms

    NASA Astrophysics Data System (ADS)

    Matsubara, Kosuke; Koshida, Kichiro; Lin, Pei-Jan Paul; Fukuda, Atsushi

    2015-07-01

    Our objective was to investigate the operating characteristics of tube current modulation (TCM) in computed tomography (CT) when scanning two types of simple-shaped phantoms. A tissueequivalent elliptical phantom and a homogeneous cylindrical step phantom comprising 16-, 24-, and 32-cm-diameter polymethyl methacrylate (PMMA) phantoms were scanned by using an automatic exposure control system with longitudinal (z-) and angular-longitudinal (xyz-) TCM and with a fixed tube current. The axial dose distribution throughout the elliptical phantom and the longitudinal dose distribution at the center of the cylindrical step phantom were measured by using a solid-state detector. Image noise was quantitatively measured at eight regions in the elliptical phantom and at 90 central regions in contiguous images over the full z extent of the cylindrical step phantom. The mean absorbed doses and the standard deviations in the elliptical phantom with z- and xyz-TCM were 12.3' 3.7 and 11.3' 3.5 mGy, respectively. When TCM was activated, some differences were observed in the absorbed doses of the left and the right measurement points. The average image noises in Hounsfield units (HU) and the standard deviations were 15.2' 2.4 and 15.9' 2.4 HU when using z- and xyz-TCM, respectively. With respect to the cylindrical step phantom under z-TCM, there were sudden decreases followed by increases in image noise at the interfaces with the 24- and 16-cm-diameter phantoms. The image noise of the 24-cm-diameter phantom was, relatively speaking, higher than those of the 16- and 32-cm-diameter phantoms. The simple-shaped phantoms used in this study can be employed to investigate the operating characteristics of automatic exposure control systems when specialized phantoms designed for that purpose are not available.

  2. Characteristics of Air Core and Surface Velocity for Water Flow in a Vortex Sediment-Extraction Chamber Measured by Using Photo Images and PTV Technique.

    NASA Astrophysics Data System (ADS)

    Yao, Hou Chang; Chyan Deng, Jan; Chao, Hsu Yu; Chih Yuan, Yang

    2017-04-01

    A vortex sediment-extraction chamber, consisted of cylindrical chamber, inflow system, bottom orifice and overflow weir, is used to separate sediment from sediment-laden water flow. A tangential inflow is introduced into a cylindrical chamber with a bottom orifice; thus, a strong vortex flow is produced there. Under actions of gravity and centrifugal force, heavier sediment particles are forced to move towards the bottom orifice, and relatively clear water flows over through the top overflow weir. The flow field in the cylindrical chamber consists of forced vortex and free vortex. When the bottom orifice is opened during the sediment-extraction process, an air core appears and changes with different settings. In this study, the air core and water surface velocity in the cylindrical chamber were measured by using a photo image process and particle tracking velocimetry (PTV), as well as numerically simulated by using a commercial software, Flow-3D.Laboratory experiments were conducted in a vortex chamber, having height of 130 cm and diameter of 48 cm. Five kinds of bottom orifice size from 1.0 cm to 3.0 cm and four kinds of inflow water discharge from 1,300cm3/s to 1,700 cm3/s were used while the inflow pipe of 3 cm in diameter was kept the same for all experiments. The characteristics of the air core and water surface velocity, and the inflow and outflow ratios under different experimental arrangements were observed and discussed so as to provide a better design and application for a vortex sediment-extraction chamber in the future.

  3. Gate simulation of Compton Ar-Xe gamma-camera for radionuclide imaging in nuclear medicine

    NASA Astrophysics Data System (ADS)

    Dubov, L. Yu; Belyaev, V. N.; Berdnikova, A. K.; Bolozdynia, A. I.; Akmalova, Yu A.; Shtotsky, Yu V.

    2017-01-01

    Computer simulations of cylindrical Compton Ar-Xe gamma camera are described in the current report. Detection efficiency of cylindrical Ar-Xe Compton camera with internal diameter of 40 cm is estimated as1-3%that is 10-100 times higher than collimated Anger’s camera. It is shown that cylindrical Compton camera can image Tc-99m radiotracer distribution with uniform spatial resolution of 20 mm through the whole field of view.

  4. Electroform replication of grazing incidence X-ray optics. [spaceborne telescopes

    NASA Technical Reports Server (NTRS)

    Ulmer, M. P.; Purcell, W. R.; Bedford, D.; Simnett, G. R.

    1985-01-01

    Work to produce mirrors via electroform replication is reported. Work on small (6 cm by 9 cm) cylindrical pieces and on 40 cm long by 12 cm wide Wolter shaped mirrors is summarized. It is shown that electroforming is a viable technique for producing relatively inexpensive grazing incidence X-ray optics, as long as modest resolution (1 min of arc) and size (12 cm diameter by 40 cm long) are specified.

  5. 23RD International Conference on Phenomena in Ionized Gases, Volume 5

    DTIC Science & Technology

    1998-12-01

    eNm.f, generated within the plasma is given by section with a 5-cm diameter. The magnetic field was Vof = wh Bt p i vn provided by an iron- core ...cylindrical tungsten probes, of 0.038cm. as impurities can be centrifuged as reported by diameter, insulated by thin glass tube except their tips Bonnevier...Norfolk, VA 213529 1. Discharge modes discharge begins, at several hundred Torr, to change from a hollow cathode discharge into what we Experimental

  6. Microcalcification detectability using a bench-top prototype photon-counting breast CT based on a Si strip detector.

    PubMed

    Cho, Hyo-Min; Ding, Huanjun; Barber, William C; Iwanczyk, Jan S; Molloi, Sabee

    2015-07-01

    To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT system were simulated using a simulation package written in matlab to determine the smallest detectable μCa. A 14 cm diameter cylindrical phantom made of breast tissue with 20% glandularity was used to simulate an average-sized breast. Five different size groups of calcium carbonate grains, from 100 to 180 μm in diameter, were simulated inside of the cylindrical phantom. The images were acquired with a mean glandular dose (MGD) in the range of 0.7-8 mGy. A total of 400 images was used to perform a reader study. Another simulation study was performed using a 1.6 cm diameter cylindrical phantom to validate the experimental results from a bench-top prototype breast CT system. In the experimental study, a bench-top prototype CT system was constructed using a tungsten anode x-ray source and a single line 256-pixels Si strip photon-counting detector with a pixel pitch of 100 μm. Calcium carbonate grains, with diameter in the range of 105-215 μm, were embedded in a cylindrical plastic resin phantom to simulate μCas. The physical phantoms were imaged at 65 kVp with an entrance exposure in the range of 0.6-8 mGy. A total of 500 images was used to perform another reader study. The images were displayed in random order to three blinded observers, who were asked to give a 4-point confidence rating on each image regarding the presence of μCa. The μCa detectability for each image was evaluated by using the average area under the receiver operating characteristic curve (AUC) across the readers. The simulation results using a 14 cm diameter breast phantom showed that the proposed photon-counting breast CT system can achieve high detection accuracy with an average AUC greater than 0.89 ± 0.07 for μCas larger than 120 μm in diameter at a MGD of 3 mGy. The experimental results using a 1.6 cm diameter breast phantom showed that the prototype system can achieve an average AUC greater than 0.98 ± 0.01 for μCas larger than 140 μm in diameter using an entrance exposure of 1.2 mGy. The proposed photon-counting breast CT system based on a Si strip detector can potentially offer superior image quality to detect μCa with a lower dose level than a standard two-view mammography.

  7. Flow rate of some pharmaceutical diluents through die-orifices relevant to mini-tableting.

    PubMed

    Kachrimanis, K; Petrides, M; Malamataris, S

    2005-10-13

    The effects of cylindrical orifice length and diameter on the flow rate of three commonly used pharmaceutical direct compression diluents (lactose, dibasic calcium phosphate dihydrate and pregelatinised starch) were investigated, besides the powder particle characteristics (particle size, aspect ratio, roundness and convexity) and the packing properties (true, bulk and tapped density). Flow rate was determined for three different sieve fractions through a series of miniature tableting dies of different orifice diameter (0.4, 0.3 and 0.2 cm) and thickness (1.5, 1.0 and 0.5 cm). It was found that flow rate decreased with the increase of the orifice length for the small diameter (0.2 cm) but for the large diameter (0.4 cm) was increased with the orifice length (die thickness). Flow rate changes with the orifice length are attributed to the flow regime (transitional arch formation) and possible alterations in the position of the free flowing zone caused by pressure gradients arising from the flow of self-entrained air, both above the entrance in the die orifice and across it. Modelling by the conventional Jones-Pilpel non-linear equation and by two machine learning algorithms (lazy learning, LL, and feed-forward back-propagation, FBP) was applied and predictive performance of the fitted models was compared. It was found that both FBP and LL algorithms have significantly higher predictive performance than the Jones-Pilpel non-linear equation, because they account both dimensions of the cylindrical die opening (diameter and length). The automatic relevance determination for FBP revealed that orifice length is the third most influential variable after the orifice diameter and particle size, followed by the bulk density, the difference between bulk and tapped densities and the particle convexity.

  8. The development of an 85-kW (thermal) steam Rankine solar receiver

    NASA Technical Reports Server (NTRS)

    Wright, C. C.; Bank, H.

    1981-01-01

    The receiver is a once-through monotube boiler designed for steam/electric and process steam applications at pressures up to 17.24 MPa (2500 psia) and temperatures up to 704 C (1300 F). The unit is 76.2 cm (30.0 in.) in diameter and 95.8 cm (37.7 in.) in length; it weighs 220 kg (485 lb). Its heat transfer surface, which is 45.7 cm (18 in.) in diameter by 57 cm (22.4 in.) long, is an Inconel 625, cylindrical, tube-coil assembly composed of primary and reheat sections. A test unit was successfully operated at up to 6.9 MPa (1000 psia) and 704 C (1300 F) with solar input from a 11-m-dia parabolic dish concentrator.

  9. Large-aperture interferometer using local reference beam

    NASA Technical Reports Server (NTRS)

    Howes, W. L.

    1982-01-01

    A large-aperture interferometer was devised by adding a local-reference-beam-generating optical system to a schlieren system. Two versions of the interferometer are demonstrated, one employing 12.7 cm (5 in.) diameter schlieren optics, the other employing 30.48 cm (12 in.) diameter parabolic mirrors in an off-axis system. In the latter configuration a cylindrical lens is introduced near the light source to correct for astigmatism. A zone plate is a satisfactory decollimating element in the reference-beam arm of the interferometer. Attempts to increase the flux and uniformity of irradiance in the reference beam by using a diffuser are discussed.

  10. Investigation of the characteristics of Automatic Exposure Control (AEC) of a Computed Tomography (CT) scanner by utilising cylindrical and anthropomorphic phantoms

    NASA Astrophysics Data System (ADS)

    Rulaidi, W. E. P.; Huri, M. S. N.; Ng, K. H.

    2017-05-01

    One method to optimise the use of x-rays in CT and hence a reduction in patient dose is the application of automatic exposure control (AEC). This study measured the effective mAs, image noise and volume CT dose index (CTDIvol) as the result of changing the AEC index on a Siemens Somatom Definition 64 slices dual source CT scanner. The scans were performed on four phantoms of different geometries, namely the 16 and 32 cm cylindrical CTDI phantoms and two anthropomorphic phantoms, RANDO (20 cm effective diameter) and ATOM (19.8 cm effective diameter). Results showed that the effective mAs increased with increasing tube potential (kVp) and Quality Reference mAs (QRM), therefore increasing CTDIvol while reducing image noise. Meanwhile, no changes of radiation dose and image noise were observed when the pitch was increased. However, for the largest phantom (32 cm effective diameter), a constant effective mAs was found between 120 and 140 kVp. The same trend was also found with increasing QRM from 300 mAs to 400 mAs suggesting a certain limitation of the AEC has been reached. In conclusion, this study showed that AEC is affected by kVp and QRM but not by pitch selection. Further work is required to quantify the characteristics of the AEC system in relation to the mentioned parameters for better optimisation.

  11. Automated Figuring and Polishing of Replication Mandrels for X-Ray Telescopes

    NASA Technical Reports Server (NTRS)

    Krebs, Carolyn (Technical Monitor); Content, David; Fleetwood, Charles; Wright, Geraldine; Arsenovic, Petar; Collela, David; Kolos, Linette

    2003-01-01

    In support of the Constellation X mission the Optics Branch at Goddard Space Flight Center is developing technology for precision figuring and polishing of mandrels used to produce replicated mirrors that will be used in X-Ray telescopes. Employing a specially built machine controlled in 2 axes by a computer, we are doing automated polishing/figuring of 15 cm long, 20 cm diameter cylindrical, conical and Wolter mandrels. A battery of tests allow us to fully characterize all important aspects of the mandrels, including surface figure and finish, mid-frequency errors, diameters and cone angle. Parts are currently being produced with surface roughnesses at the .5nm RMS level, and half-power diameter slope error less than 2 arcseconds.

  12. Electron beam extraction on plasma cathode electron sources system

    NASA Astrophysics Data System (ADS)

    Purwadi, Agus; Taufik, M., Lely Susita R.; Suprapto, Saefurrochman, H., Anjar A.; Wibowo, Kurnia; Aziz, Ihwanul; Siswanto, Bambang

    2017-03-01

    ELECTRON BEAM EXTRACTION ON PLASMA CATHODE ELECTRON SOURCES SYSTEM. The electron beam extraction through window of Plasma Generator Chamber (PGC) for Pulsed Electron Irradiator (PEI) device and simulation of plasma potential has been studied. Plasma electron beam is extracted to acceleration region for enlarging their power by the external accelerating high voltage (Vext) and then it is passed foil window of the PEI for being irradiated to any target (atmospheric pressure). Electron beam extraction from plasma surface must be able to overcome potential barrier at the extraction window region which is shown by estimate simulation (Opera program) based on data of plasma surface potential of 150 V with Ueks values are varied by 150 kV, 175 kV and 200 kV respectively. PGC is made of 304 stainless steel with cylindrical shape in 30 cm of diameter, 90 cm length, electrons extraction window as many as 975 holes on the area of (15 × 65) cm2 with extraction hole cell in 0.3 mm of radius each other, an cylindrical shape IEP chamber is made of 304 stainless steel in 70 cm diameter and 30 cm length. The research result shown that the acquisition of electron beam extraction current depends on plasma parameters (electron density ne, temperature Te), accelerating high voltage Vext, the value of discharge parameter G, anode area Sa, electron extraction window area Se and extraction efficiency value α.

  13. Use of vacuum arc plasma guns for a metal puff Z-pinch system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rousskikh, A. G.; Zhigalin, A. S.; Oreshkin, V. I.

    The performance of a metal puff Z-pinch system has been studied experimentally. In this type of system, the initial cylindrical shell 4 cm in diameter was produced by ten plasma guns. Each gun initiates a vacuum arc operating between magnesium electrodes. The net current of the guns was 80 kA. The arc-produced plasma shell was compressed by using a 450-kA, 450-ns driver, and as a result, a plasma column 0.3 cm in diameter was formed. The electron temperature of the plasma reached 400 eV at an average ion concentration of 1.85 {center_dot} 10{sup 18} cm{sup -3}. The power of themore » Mg K-line radiation emitted by the plasma for 15-30 ns was 300 MW/cm.« less

  14. Development of a collapsible reinforced cylindrical space observation window

    NASA Technical Reports Server (NTRS)

    Khan, A. Q.

    1971-01-01

    Existing material technology was applied to the development of a collapsible transparent window suitable for manned spacecraft structures. The effort reported encompasses the evaluation of flame retardants intended for use in the window matrix polymer, evaluation of reinforcement angle which would allow for a twisting pantographing motion as the cylindrical window is mechanically collapsed upon itself, and evaluation of several reinforcement embedment methods. A fabrication technique was developed to produce a reinforced cylindrical space window of 45.7 cm diameter and 61.0 cm length. The basic technique involved the application of a clear film on a male-section mold; winding axial and girth reinforcements and vacuum casting the outer layer. The high-strength transparent window composite consisted of a polyether urethane matrix reinforced with an orthogonal pattern of black-coated carbon steel wire cable. A thin film of RTV silicone rubber was applied to both surfaces of the urethane. The flexibility, retraction system, and installation system are described.

  15. Nuclear characteristics of a fissioning uranium plasma test reactor with light-water cooling

    NASA Technical Reports Server (NTRS)

    Whitmarsh, C. L., Jr.

    1973-01-01

    An analytical study was performed to determine a design configuration for a cavity test reactor. Test section criteria were that an average flux of 10 to the 15th power neutrons/sq cm/sec (E less than or equal to 0.12 eV) be supplied to a 61-cm-diameter spherical cavity at 200-atm pressure. Design objectives were to minimize required driver power, to use existing fuel-element technology, and to obtain fuel-element life of 10 to 100 full-power hours. Parameter calculations were made on moderator region size and material, driver fuel arrangement, control system, and structure in order to determine a feasible configuration. Although not optimized, a configuration was selected which would meet design criteria. The driver fuel region was a cylindrical annular region, one element thick, of 33 MTR-type H2O-cooled elements (Al-U fuel plate configuration), each 101 cm long. The region between the spherical test cavity and the cylindrical driver fuel region was Be (10 vol. % H2O coolant) with a midplane dimension of 8 cm. Exterior to the driver fuel, the 25-cm-thick cylindrical and axial reflectors were also Be with 10 vol. % H2O coolant. The entire reactor was contained in a 10-cm-thick steel pressure vessel, and the 200-atm cavity pressure was equalized throughout the driver reactor. Fuel-element life was 50 hr at the required driver power of 200 MW. Reactor control would be achieved with rotating poison drums located in the cylindrical reflector region. A control range of about 18 percent delta k/k was required for reactor operation.

  16. Angular and radial dependence of the energy response factor for LIF-TLD micro-rods in 125L permanent implant source.

    PubMed

    Mobit, Paul; Badragan, Iulian

    2006-01-01

    EGSnrc Monte Carlo simulations were used to calculate the angular and radial dependence of the energy response factor for LiF-thermoluminescence dosemeters (TLDs) irradiated with a commercially available (125)I permanent brachytherapy source. The LiF-TLDs were modelled as cylindrical micro-rods of length 6 mm and with diameters of 1 mm and 5 mm. The results show that for a LiF-TLD micro-rod of 1 mm diameter, the energy response relative to (60)Co gamma rays is 1.406 +/- 0.3% for a polar angle of 90 degrees and radial distance of 1.0 cm. When the diameter of the micro-rod is increased from 1 to 5 mm, the energy response decreases to 1.32 +/- 0.3% at the same point. The variation with position of the energy response factor is not >5% in a 6 cm x 6 cm x 6 cm calculation grid for the 5 mm diameter micro-rod. The results show that there is a change in the photon spectrum with angle and radial distance, which causes the variation of the energy response.

  17. A Study of the Electrostatic Interaction Between Insulators and Martian/Lunar Soil Simulants

    NASA Technical Reports Server (NTRS)

    Mantovani, James G.

    2001-01-01

    Using our previous experience with the Mars Environmental Compatibility Assessment (MECA) electrometer, we have designed a new type of aerodynamic electrometer. The goal of the research was to measure the buildup of electrostatic surface charge on a stationary cylindrical insulator after windborne granular particles have collided with the insulator surface in a simulated dust storm. The experiments are performed inside a vacuum chamber. This allows the atmospheric composition and pressure to be controlled in order to simulate the atmospheric conditions near the equator on the Martian surface. An impeller fan was used to propel the dust particles at a cylindrically shaped insulator under low vacuum conditions. We tested the new electrometer in a 10 mbar CO2 atmosphere by exposing two types of cylindrical insulators, Teflon (1.9 cm diameter) and Fiberglass (2.5 cm diameter), to a variety of windborne granular particulate materials. The granular materials tested were JSC Mars-1 simulant, which is a mixture of coarse and fine (<5microns diameter) particle sizes, and some of the major mineral constituents of the Martian soil. The minerals included Ottawa sand (SiO2), iron oxide (Fe2O3), aluminum oxide (Al2O3) and magnesium oxide (MgO). We also constructed a MECA-like electrometer that contained an insulator capped planar electrode for measuring the amount of electrostatic charge produced by rubbing an insulator surface over Martian and lunar soil simulants. The results of this study indicate that it is possible to detect triboelectric charging of insulator surfaces by windborne Martian soil simulant, and by individual mineral constituents of the soil simulant. We have also found that Teflon and Fiberglass insulator surfaces respond in different ways by developing opposite polarity surface charge, which decays at different rates after the particle impacts cease.

  18. Plasma rotation in the Peking University Plasma Test device.

    PubMed

    Xiao, Chijie; Chen, Yihang; Yang, Xiaoyi; Xu, Tianchao; Wang, Long; Xu, Min; Guo, Dong; Yu, Yi; Lin, Chen

    2016-11-01

    Some preliminary results of plasma rotations in a linear plasma experiment device, Peking University Plasma Test (PPT) device, are reported in this paper. PPT has a cylindrical vacuum chamber with 500 mm diameter and 1000 mm length, and a pair of Helmholtz coils which can generate cylindrical or cusp magnetic geometry with magnitude from 0 to 2000 G. Plasma was generated by a helicon source and the typical density is about 10 13 cm -3 for the argon plasma. Some Langmuir probes, magnetic probes, and one high-speed camera are set up to diagnose the rotational plasmas. The preliminary results show that magnetic fluctuations exist during some plasma rotation processes with both cylindrical and cusp magnetic geometries, which might be related to some electromagnetic processes and need further studies.

  19. PHYSICAL EFFECTS OCCURRING DURING GENERATION AND AMPLIFICATION OF LASER RADIATION: Ultimate values of the gain of solid-state rod amplifiers operating under inversion storage conditions

    NASA Astrophysics Data System (ADS)

    Bayanov, V. I.; Vinokurov, G. N.; Zhulin, V. I.; Yashin, V. E.

    1989-02-01

    A numerical calculation is reported of an inversion conservation coefficient of cylindrical rod solid-state amplifiers with the active element diameter from 1.5 to 15 cm operated under continuous pumping conditions. It is shown that the ultimate gain, limited only by superluminescence, exceeds considerably the value usually obtained in experiments. Various methods of eliminating parasitic effects, which limit the gain of real amplifiers, are considered. The degree of influence of these effects on the inversion conservation coefficient is discussed. The results are given of an experimental determination of the gain close to the ultimate value (0.18 cm- 1 for an active element 3 cm in diameter). Calculations are reported of the angular distributions of superluminescence and parasitic modes demonstrating that the latter can be suppressed by spatial filtering.

  20. Experimental investigation of electron guns for THz microwave vacuum amplifiers

    NASA Astrophysics Data System (ADS)

    Burtsev, A. A.; Grigor'ev, Yu. A.; Navrotsky, I. A.; Rogovin, V. I.; Sakhadzhi, G. V.; Shumikhin, K. V.

    2016-05-01

    Single-sheet and multiple beam electron emitters based on thermionic minicathodes for terahertz traveling-wave tubes have been studied. Data are presented for impregnated blade thermionic cathode with dimensions 0.1 × 0.7 mm and a maximum current density of 114 A/cm2 in a pulsed mode. A variant of the five-beam electron gun with 0.25-mm-diameter cylindrical minicathodes in cells of a control grid is proposed that provides a current density of 85.5 A/cm2 at a grid potential of 900-1000 V.

  1. Feasibility of Using Lateral Mode Coupling Method for a Large Scale Ultrasound Phased Array for Noninvasive Transcranial Therapy

    PubMed Central

    Song, Junho; Hynynen, Kullervo

    2009-01-01

    A hemispherical-focused, ultrasound phased array was designed and fabricated using 1372 cylindrical piezoelectric transducers that utilize lateral coupling for noninvasive transcranial therapy. The cylindrical transducers allowed the electrical impedance to be reduced by at least an order of magnitude, such that effective operation could be achieved without electronic matching circuits. In addition, the transducer elements generated the maximum acoustic average surface intensity of 27 W/cm2. The array, driven at the low (306 kHz) or high frequency (840 kHz), achieved excellent focusing through an ex vivo human skull and an adequate beam steering range for clinical brain treatments. It could electronically steer the ultrasound beam over cylindrical volumes of 100 mm in diameter and 60 mm in height at 306 kHz, and 30-mm in diameter and 30-mm in height at 840 kHz. A scanning laser vibrometer was used to investigate the radial and length mode vibrations of the element. The maximum pressure amplitudes through the skull at the geometric focus were predicted to be 5.5 MPa at 306 kHz and 3.7 MPa at 840 kHz for RF power of 1 W on each element. This is the first study demonstrating the feasibility of using cylindrical transducer elements and lateral coupling in construction of ultrasound phased arrays. PMID:19695987

  2. Design and Assembly of the Magnetized Dusty Plasma Experiment (MDPX)

    NASA Astrophysics Data System (ADS)

    Fisher, Ross; Artis, Darrick; Lynch, Brian; Wood, Keith; Shaw, Joseph; Gilmore, Kevin; Robinson, Daniel; Polka, Christian; Konopka, Uwe; Thomas, Edward; Merlino, Robert; Rosenberg, Marlene

    2013-10-01

    Over the last two years, the Magnetized Dusty Plasma Experiment (MDPX) has been under construction at Auburn University. This new research device, whose assembly will be completed in late Summer, 2013, uses a four-coil, superconducting, high magnetic field system (|B | >= 4 Tesla) to investigate the confinement, charging, transport, and instabilities in a dusty plasma. A new feature of the MDPX device is the ability to operate the magnetic coils independently to allow a variety of magnetic configurations from highly uniform to quadrapole-like. Envisioned as a multi-user facility, the MDPX device features a cylindrical vacuum vessel whose primary experimental region is an octagonal chamber that has a 35.5 cm inner diameter and is 19 cm tall. There is substantial diagnostics and optical access through eight, 10.2 cm × 12.7 cm side ports. The chamber can also be equipped with two 15.2 cm diameter, 76 cm long extensions to allow long plasma column experiments, particularly long wavelength dust wave studies. This presentation will discuss the final design, assembly, and installation of the MDPX device and will describe its supporting laboratory facility. This work is supported by a National Science Foundation - Major Research Instrumentation (NSF-MRI) award, PHY-1126067.

  3. Helium temperature measurements in a hot filament magnetic mirror plasma using high resolution Doppler spectroscopy

    NASA Astrophysics Data System (ADS)

    Knott, S.; McCarthy, P. J.; Ruth, A. A.

    2016-09-01

    Langmuir probe and spectroscopic diagnostics are used to routinely measure electron temperature and density over a wide operating range in a reconfigured Double Plasma device at University College Cork, Ireland. The helium plasma, generated through thermionic emission from a negatively biased tungsten filament, is confined by an axisymmetric magnetic mirror configuration using two stacks of NdFeB permanent magnets, each of length 20 cm and diameter 3 cm placed just outside the 15 mm water cooling jacket enclosing a cylindrical vacuum vessel of internal diameter 25 cm. Plasma light is analysed using a Fourier Transform-type Bruker spectrometer with a highest achievable resolution of 0.08 cm-1 . In the present work, the conventional assumption of room temperature ions in the analysis of Langmuir probe data from low temperature plasmas is examined critically using Doppler spectroscopy of the 468.6 nm He II line. Results for ion temperatures obtained from spectroscopic data for a variety of engineering parameters (discharge voltage, gas pressure and plasma current) will be presented.

  4. SU-E-J-17: Evaluation of Metal Artifact Reduction in MVCTs Using a Model Based Image Reconstruction Method.

    PubMed

    Paudel, M; MacKenzie, M; Fallone, B; Rathee, S

    2012-06-01

    To evaluate the performance of a model based image reconstruction in reducing metal artifacts in MVCT systems, and to compare with filtered-back projection (FBP) technique. Iterative maximum likelihood polychromatic algorithm for CT (IMPACT) is used with pair/triplet production process and the energy dependent response of detectors. The beam spectra for in-house bench-top and TomotherapyTM MVCT are modelled for use in IMPACT. The energy dependent gain of detectors is calculated using a constrained optimization technique and measured attenuation produced by 0 - 24 cm thick solid water slabs. A cylindrical (19 cm diameter) plexiglass phantom containing various central cylindrical inserts (relative electron density of 0.28-1.69) between two steel rods (2 cm diameter) is scanned in the bench-top [the bremsstrahlung radiation from 6 MeV electron beam passed through 4 cm solid water on the Varian Clinac 2300C] and TomotherapyTM MVCTs. The FBP reconstructs images from raw signal normalised to air scan and corrected for beam hardening using a uniform plexi-glass cylinder (20 cm diameter). IMPACT starts with FBP reconstructed seed image and reconstructs final image at 1.25 MeV in 150 iterations. FBP produces a visible dark shading in the image between two steel rods that becomes darker with higher density central insert causing 5-8 % underestimation of electron density compared to the case without the steel rods. In the IMPACT image the dark shading connecting the steel rods is nearly removed and the uniform background restored. The average attenuation coefficients of the inserts and the background are very close to the corresponding theoretical values at 1.25 MeV. The dark shading metal artifact due to beam hardening can be removed in MVCT using the iterative reconstruction algorithm such as IMPACT. However, the accurate modelling of detectors' energy dependent response and physical processes are crucial for successful implementation. Funding support for the research is obtained from "Vanier Canada Graduate Scholarship" and "Canadian Institute of Health Research". © 2012 American Association of Physicists in Medicine.

  5. Magnetic Fields of the Cerebral Cortex,

    DTIC Science & Technology

    1980-06-15

    with worm gears on two separate horizontal shafts . One shaft (the declination axle ) near the end of the frame rotates the dewar. The other near the...carriage is fabricated from fiberglass or wood wherever possible. Vertical movement of the dewar is permitted by a 6 cm diameter cylindrical axle of...hardwood that runs between sets of aluminum rollers having double conical shape. The axle is supported by four strands of nylon parachute cord, each

  6. Experimental characterization of HOTNES: A new thermal neutron facility with large homogeneity area

    NASA Astrophysics Data System (ADS)

    Bedogni, R.; Sperduti, A.; Pietropaolo, A.; Pillon, M.; Pola, A.; Gómez-Ros, J. M.

    2017-01-01

    A new thermal neutron irradiation facility, called HOTNES (HOmogeneous Thermal NEutron Source), was established in the framework of a collaboration between INFN-LNF and ENEA-Frascati. HOTNES is a polyethylene assembly, with about 70 cmx70 cm square section and 100 cm height, including a large, cylindrical cavity with diameter 30 cm and height 70 cm. The facility is supplied by a 241Am-B source located at the bottom of this cavity. The facility was designed in such a way that the iso-thermal-fluence surfaces, characterizing the irradiation volume, coincide with planes parallel to the cavity bottom. The thermal fluence rate across a given isofluence plane is as uniform as 1% on a disk with 30 cm diameter. Thermal fluence rate values from about 700 cm-2 s-1 to 1000 cm-2 s-1 can be achieved. The facility design, previously optimized by Monte Carlo simulation, was experimentally verified. The following techniques were used: gold activation foils to assess the thermal fluence rate, semiconductor-based active detector for mapping the irradiation volume, and Bonner Sphere Spectrometer to determine the complete neutron spectrum. HOTNES is expected to be attractive for the scientific community involved in neutron metrology, neutron dosimetry and neutron detector testing.

  7. Thermal neutron flux mapping in a head phantom

    NASA Astrophysics Data System (ADS)

    Lee, C. L.; Zhou, X.-L.; Harmon, J. F.; Bartholomay, R. W.; Harker, Y. D.; Kudchadker, R. J.

    1999-02-01

    Boron neutron capture therapy (BNCT) is a binary cancer treatment modality in which a boron-containing compound is preferentially loaded into a tumor, followed by irradiation by thermal neutrons. In accelerator-based BNCT, neutrons are produced by charged particle-induced reactions such as 7Li(p, n) 7Be. For deeply seated brain tumors, epithermal (1 eV to 10 kev) neutrons are needed to penetrate the skull cap and subsequently thermalize at the tumor location. Cell damage in BNCT is caused by the high linear energy transfer (LET) products from the 10B(n, α) 7Li reaction. Because the cross section for this reaction is of 1/ v character, the dose due to 10B has essentially the same spatial distribution as the thermal neutron flux. A cylindrical acrylic head phantom (15.24 cm diameter by 21.59 cm length) has been constructed to simulate the patient's head and neck, and acrylic spacers of varying width allow placement of small (active sizes: 0.635 cm diameter by 1.27 cm length and 1.5875 cm diameter by 2.54 cm length) BF 3 proportional counters at nearly all radial and axial locations. Measurements of the thermal flux have also been benchmarked with gold and indium foils (bare and cadmium covered), as well as MCNP simulations. Measurement of the thermal neutron flux using these small BF 3 counters is shown to be adequate for experimentally determining the spatial variation of the 10B dose in head phantoms for accelerator-based BNCT.

  8. Velocity profile of water vapor inside a cavity with two axial inlets and two outlets

    NASA Astrophysics Data System (ADS)

    Guadarrama-Cetina, José; Ruiz Chavarría, Gerardo

    2014-03-01

    To study the dynamics of Breath Figure phenomenon, a control of both the rate of flow and temperature of water vapor is required. The experimental setup widely used is a non hermetically closed chamber with cylindrical geometry and axial inlets and outlets. In this work we present measurements in a cylindrical chamber with diameter 10 cm and 1.5 cm height, keeping a constant temperature (10 °C). We are focused in the velocity field when a gradient of the temperatures is produced between the base plate and the vapor. With a flux of water vapor of 250 mil/min at room temperature (21 °C), the Reynolds number measured in one inlet is 755. Otherwise, the temperatures of water vapor varies from 21 to 40 °C. The velocity profile is obtained by hot wire anemometry. We identify the stagnations and the possibly instabilities regions for an empty plate and with a well defined shape obstacle as a fashion sample. Facultad de Ciencias, UNAM.

  9. Analytic drain current model for III-V cylindrical nanowire transistors

    NASA Astrophysics Data System (ADS)

    Marin, E. G.; Ruiz, F. G.; Schmidt, V.; Godoy, A.; Riel, H.; Gámiz, F.

    2015-07-01

    An analytical model is proposed to determine the drain current of III-V cylindrical nanowires (NWs). The model uses the gradual channel approximation and takes into account the complete analytical solution of the Poisson and Schrödinger equations for the Γ-valley and for an arbitrary number of subbands. Fermi-Dirac statistics are considered to describe the 1D electron gas in the NWs, being the resulting recursive Fermi-Dirac integral of order -1/2 successfully integrated under reasonable assumptions. The model has been validated against numerical simulations showing excellent agreement for different semiconductor materials, diameters up to 40 nm, gate overdrive biases up to 0.7 V, and densities of interface states up to 1013eV-1cm-2 .

  10. A simple on-line arterial time-activity curve detector for [O-15] water PET studies

    NASA Astrophysics Data System (ADS)

    Wollenweber, S. D.; Hichwa, R. D.; Ponto, L. L. B.

    1997-08-01

    A simple, automated on-line detector system has been fabricated and implemented to detect the arterial time-activity curve (TAG) for bolus-injection [O-15] water PET studies. This system offers two significant improvements over existing systems: a pump mechanism is not required to control arterial blood flow through the detector and dispersion correction of the time-activity curve for dispersion in external tubing is unnecessary. The [O-15] positrons emanating from blood within a thin-walled, 0.134 cm inner-diameter plastic tube are detected by a 0.5 cm wide by 1.0 cm long by 0.1 cm thick plastic scintillator mounted to a miniature PMT. Photon background is reduced to insignificant levels by a 2.0 cm thick cylindrical lead shield. Mean cerebral blood flow (mCBF) determined from an autoradiographic model and from the TAC measured by 1-second automated sampling was compared to that calculated from a TAC acquired using 5-second integrated manual samples. Improvements in timing resolution (1-sec vs. 5-sec) cause small but significant differences between the two sampling methods. Dispersion is minimized due to small tubing diameters, short lengths of tubing between the radial arterial sampling site and the detector and the presence of a 3-way valve 10 cm proximal to the detector.

  11. Experiments with planar inductive ion source meant for creation of H+ beams.

    PubMed

    Vainionpaa, J H; Kalvas, T; Hahto, S K; Reijonen, J

    2007-06-01

    In this article the effects of different engineering parameters of rf-driven ion sources with an external spiral antenna and a quartz rf window are studied. This article consists of three main topics: the effect of source geometry on the operation gas pressure, the effect of source materials and magnetic confinement on extracted current density and ion species, and the effect of different antenna geometries on the extracted current density. The effect of source geometry was studied using three cylindrical plasma chambers with different inner diameters. The chamber materials were studied using two materials, aluminum (Al) and alumina (Al(2)O(3)). The removable 14 magnet multicusp confinement arrangement enabled us to compare the effects of the two wall materials with and without the magnetic confinement. The highest measured proton fractions were measured using Al(2)O(3) plasma chamber and no multicusp confinement. For the compared ion sources the source with multicusp confinement and Al(2)O(3) plasma chamber yields the highest current densities. Multicusp confinement increased the maximum extracted current by up to a factor of 2. Plasma production with different antenna geometries were also studied. The highest current density was achieved using 4.5 loop solenoid antenna with 6.0 cm diameter. A slightly lower current density with lower pressure was achieved using a tightly wound 3 loop spiral antenna with 3.3 cm inner diameter and 6 cm outer diameter.

  12. Characterization of Siarang Dairi local corn, Regency of Dairi, North Sumatera Province

    NASA Astrophysics Data System (ADS)

    Nasution, L. Z.; Buri, N.

    2018-05-01

    Corn is one of the carbohydrate-producing plants in addition to rice and wheat which contains nutrients that can be used for humans and animals. Local plants have an important role for genetic resources and can create new varieties. So it needs to be preserved and utilized. The purpose of this research is to characterize the local maize of Siarang Dairi. This research uses qualitative method is descriptive analysis. The data collected include the quantitative and qualitative character of agronomic and morphological characters using 5 plant samples. The results showed that the local Siarang Dairi maize had a root falling percentage of 0% and the stem fall percentage of 3.07%. The high of the plant ranged from 236 - 277 cm. The length of the cob were from 16 - 19 cm with an almost homogen diameter of 4 – 4.5 cm. The uppermost form of cylindrical and cylindrical conical. Grain lengths range from 6 - 8 mm, with grain widths ranging from 5 - 9 mm, and grain thicknesses ranging from 3 - 5 mm. The top grain surface shape is jagged, round, and flat. Specific color grains are unique and varied from brown, orange and red color.

  13. Transurethral canine prostatectomy with a cylindrically diffusing fiber

    NASA Astrophysics Data System (ADS)

    Cromeens, Douglas M.; Johnson, Douglas E.; Price, Roger E.

    1994-09-01

    In this study, visual laser ablation of the prostate (VLAP) was performed on eight mongrel dogs utilizing a cylindrically diffusing fiber attached to a 1.06 neodymium:YAG (Nd:YAG) laser. All dogs received one continuous dose totaling 15,000 J (25 W for 10 min) applied from the vesical neck to the colliculus seminalis. There was no visible hemorrhage from the lasing intraoperatively in any dog. Postoperative recovery was uneventful with no dog experiencing urinary incontinence and only one incident of dysuria with urinary retention during their observation period. Gross and histopathologic examinations of serial sections of the prostate were performed from 2 hours to 7 weeks postoperatively and demonstrated a consistent spherical zone of destruction 2.9 cm (average) in diameter. We believe the simplified fiber placement and complete lack of postoperative complications in this small group of dogs suggest that the cylindrically diffusing fiber offers significant advantage over laterally deflecting fibers for transurethral prostatectomies in the dog.

  14. Palm top plasma focus device as a portable pulsed neutron source.

    PubMed

    Rout, R K; Niranjan, Ram; Mishra, P; Srivastava, R; Rawool, A M; Kaushik, T C; Gupta, Satish C

    2013-06-01

    Development of a palm top plasma focus device generating (5.2 ± 0.8) × 10(4) neutrons∕pulse into 4π steradians with a pulse width of 15 ± 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 μF capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 μF, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of (3)He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

  15. Palm top plasma focus device as a portable pulsed neutron source

    NASA Astrophysics Data System (ADS)

    Rout, R. K.; Niranjan, Ram; Mishra, P.; Srivastava, R.; Rawool, A. M.; Kaushik, T. C.; Gupta, Satish C.

    2013-06-01

    Development of a palm top plasma focus device generating (5.2 ± 0.8) × 104 neutrons/pulse into 4π steradians with a pulse width of 15 ± 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 μF capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 μF, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of 3He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

  16. Fabrication and study of cylindrical scintillation counters of the ARES spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baranov, V.A.; Evtukhovich, P.G.; Korenchenko, S.M.

    A method is described for fabricating 600 x 87 x 5 mm plastic scintillation counters which are constituent elements of a 673 mm in diameter cylindrical hodoscope. Results of investigations into the amplitude and temporal characteristics of a separate scintillation are presented. Light losses in the transitional and main lightguides were determined primarily by the absorption length of the organic glass. The time resolution of the counter with the beta source placed at the center of the scintillator equaled 1 nsec; the velocity of propagation of light in the scintillator equals 12.1 cm/nsec. The ARES spectrometer detects electrons and gammamore » rays under conditions of high meson-stopping intensity and will be used for pion and muon rare decay studies.« less

  17. Design study of dedicated brain PET with polyhedron geometry.

    PubMed

    Shi, Han; Du, Dong; Xu, JianFeng; Su, Zhihong; Peng, Qiyu

    2015-01-01

    Despite being the conventional choice, whole body PET cameras with a 76 cm diameter ring are not the optimal means of human brain imaging. In fact, a dedicated brain PET with a better geometrical structure has the potential to achieve a higher sensitivity, a higher signal-to-noise ratio, and a better imaging performance. In this study, a polyhedron geometrical dedicated brain PET (a dodecahedron design) is compared to three other candidates via their geometrical efficiencies by calculating the Solid Angle Fractions (SAF); the three other candidates include a spherical cap design, a cylindrical design, and the conventional whole body PET. The spherical cap and the dodecahedron have an identical SAF that is 58.4% higher than that of a 30 cm diameter cylinder and 5.44 times higher than that of a 76 cm diameter cylinder. The conceptual polygon-shape detectors (including pentagon and hexagon detectors based on the PMT-light-sharing scheme instead of the conventional square-shaped block detector module) are presented for the polyhedron PET design. Monte Carlo simulations are performed in order to validate the detector decoding. The results show that crystals in a pentagon-shape detector can be successfully decoded by Anger Logic. The new detector designs support the polyhedron PET investigation.

  18. Multi-source irradiation facility with improved space configuration for neutron activation analysis: Design optimization.

    PubMed

    Kotb, N A; Solieman, Ahmed H M; El-Zakla, T; Amer, T Z; Elmeniawi, S; Comsan, M N H

    2018-05-01

    A neutron irradiation facility consisting of six 241 Am-Be neutron sources of 30 Ci total activity and 6.6 × 10 7 n/s total neutron yield is designed. The sources are embedded in a cubic paraffin wax, which plays a dual role as both moderator and reflector. The sample passage and irradiation channel are represented by a cylindrical path of 5 cm diameter passing through the facility core. The proposed design yields a high degree of space symmetry and thermal neutron homogeneity within 98% of flux distribution throughout the irradiated spherical sample of 5 cm diameter. The obtained thermal neutron flux is 8.0 × 10 4 n/cm 2 .s over the sample volume, with thermal-to-fast and thermal-to-epithermal ratios of 1.20 and 3.35, respectively. The design is optimized for maximizing the thermal neutron flux at sample position using the MCNP-5 code. The irradiation facility is supposed to be employed principally for neutron activation analysis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. An experimental investigation of the effect of walls on gas-liquid flows through fixed particle beds.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, Marcia A.; Cote, Raymond O.; Torczynski, John Robert

    The effect of particle diameter on downward co-current gas-liquid flow through a fixed bed of particles confined within a cylindrical column is investigated. Several hydrodynamic regimes that depend strongly on the properties of the gas stream, the liquid stream, and the packed particle bed are known to exist within these systems. This experimental study focuses on characterizing the effect of wall confinement on these hydrodynamic regimes as the diameter d of the spherical particles becomes comparable to the column diameter D (or D/d becomes order-unity). The packed bed consists of polished, solid, spherical, monodisperse particles (beads) with mean diameter inmore » the range of 0.64-2.54 cm. These diameters yield D/d values between 15 and 3.75, so this range overlaps and extends the previously investigated range for two-phase flow, Measurements of the pressure drop across the bed and across the pulses are obtained for varying gas and liquid flow rates.« less

  20. Numerical Investigation of Magnetically Driven Isentropic Compression of Solid Aluminum Cylinders with a Semi-Analytical Code

    NASA Astrophysics Data System (ADS)

    Largent, Billy T.

    The state of matter at extremely high pressures and densities is of fundamental interest to many branches of research, including planetary science, material science, condensed matter physics, and plasma physics. Matter with pressures, or energy densities, above 1 megabar (100 gigapascal) are defined as High Energy Density (HED) plasmas. They are directly relevant to the interiors of planets such as Earth and Jupiter and to the dense fuels in Inertial Confinement Fusion (ICF) experiments. To create HEDP conditions in laboratories, a sample may be compressed by a smoothly varying pressure ramp with minimal temperature increase, following the isentropic thermodynamic process. Isentropic compression of aluminum targets has been done using magnetic pressure produced by megaampere, pulsed power currents having 100 ns rise times. In this research project, magnetically driven, cylindrical isentropic compression has been numerically studied. In cylindrical geometry, material compression and pressure become higher than in planar geometry due to geometrical effects. Based on a semi-analytical model for the Magnetized Liner Inertial Fusion (MagLIF) concept, a code called "SA" was written to design cylindrical compression experiments on the 1.0 MA Zebra pulsed power generator at the Nevada Terawatt Facility (NTF). To test the physics models in the code, temporal progresses of rod compression and pressure were calculated with SA and compared with 1-D magnetohydrodynamic (MHD) codes. The MHD codes incorporated SESAME tables, for equation of state and resistivity, or the classical Spitzer model. A series of simulations were also run to find optimum rod diameters for 1.0 MA and 1.8 MA Zebra current pulses. For a 1.0 MA current peak and 95 ns rise time, a maximum compression of 2.35 ( 6.3 g/cm3) and a pressure of 900 GPa within a 100 mum radius were found for an initial diameter of 1.05 mm. For 1.8 MA peak simulations with the same rise time, the initial diameter of 1.3 mm was optimal with 3.32 ( 9.0 g/cm 3) compression.

  1. Characteristics of depth-sensing coplanar grid CdZnTe detectors

    NASA Astrophysics Data System (ADS)

    He, Zhong; Sturm, Ben W.

    2005-12-01

    The latest depth-sensing coplanar grid CdZnTe detectors have been tested. Two of these have dimensions 1.5×1.5×1.0 cm 3 and one is a cylindrical detector with 1.5 cm diameter and 1.0 cm length, all of them using the third-generation coplanar anode design. Energy resolutions of 2.0% and 2.4% FWHM at 662 keV γ-ray energies were obtained. Detector performance has been observed experimentally as a function of depth of the γ-ray interaction, and as a function of radial position near the anode surface. The measured results show the improvement of the third-generation anode design. Material uniformity of CdZnTe crystals manufactured by eV Products have been directly observed and compared on two 1.5×1.5×1.0 cm 3 detectors.

  2. TH-AB-BRA-11: Using 3D Dosimeters for the Investigation of the Electron Return Effect (ERE) in MR-Guided Radiation Therapy: A Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, G; Lee, H; Alqathami, M

    Purpose: To demonstrate the capability of 3D radiochromic PRESAGE and Fricke-type dosimeters to measure the influence of magnetic fields on dose distribution, including the electron return effect (ERE), for MR-guided radiation therapy applications. Methods: Short cylindrical 3D dosimeters with PRESAGE and Fricke-type formulations were created in-house prior to irradiations in a 1.5T/7MV MR-linac. Each dosimeter was prepared with a concentric cylindrical air cavity with diameters of 1.5 cm and 2.5 cm, and the diameters of the dosimeters were 7.2 cm and 8.8 cm for PRESAGE and Fricke-type respectively. The dosimeters were irradiated within the bore of the MR-linac with themore » flat face of the dosimeters perpendicular to the magnetic field. Dosimeters were irradiated to approximately 9 Gy and 29 Gy to the center of dosimeters with a 15×15 cm{sup 2} field. The PRESAGE dosimeter was scanned using an optical-CT 2 hours post-irradiation; the Fricke-type dosimeter was immediately imaged with the MR component of the MR-linac post-irradiation. Results: Axial slices of the dose distributions show a clear demonstration of the dose enhancement due to the ERE above the cavity and the region of reduced dose below the cavity. The regions of increased and reduced dose are rotated with respect to the radiation beam axis due to the average directional change of the electrons. Measurements from line profiles show the dose enhanced up to ∼0.5 cm around the cavity by up to a factor of 1.3 and 1.4 for PRESAGE and Fricke-type dosimeters respectively. Conclusion: PRESAGE and Fricke-type dosimeters are able to qualitatively measure the ERE with good agreement with previously published simulation and 2D dosimetry demonstrations of the ERE. Further investigation of these 3D dosimeters as promising candidates for quality assurance of MR-guided radiation therapy systems is encouraged to assess changes in response and measurement accuracy due to the magnetic field.« less

  3. Fabrication and properties of radially <001>C textured PMN-PT cylinders for transducer applications

    NASA Astrophysics Data System (ADS)

    Poterala, Stephen F.; Meyer, Richard J.; Messing, Gary L.

    2012-07-01

    <001>C Textured PMN-PT ceramics have electromechanical properties (d33 = 850-1050 pm/V, k33 = 0.79-0.83) between those of conventional PZT ceramics and relaxor PMN-PT crystals. In this work, we tailor crystallographic orientation in textured PMN-PT ceramics for transducer designs with non-planar poling surfaces. Specifically, omni-directional cylindrical transducer elements were fabricated using monolithic, radially <001>C textured and poled PMN-PT ceramic. Texture was produced by templated grain growth using NBT-PT templates, which were oriented radially by wrapping green ceramic tapes around a cylindrical mandrel. Finished transducer elements measure ˜5 cm in diameter by ˜2.5 cm in height and demonstrate scalability of textured ceramic fabrication techniques. The fabricated cylinders are ˜50 vol. % textured and show high 31-mode electromechanical properties compared to PZT ceramics (d31 = -259 pm/V, k31 = 0.43, ɛT33 = 3000, and Qm = 350). Frequency bandwidth is related to the square of the hoop mode coupling coefficient kh2, which is ˜60% higher in textured PMN-PT cylinders compared to PZT 5H. Finite element simulations show that this parameter may be further increased by improving texture quality to ≥90 vol. %. Radially textured PMN-PT may thus improve performance in omni-directional cylindrical transducers while avoiding the need for segmented single crystal designs.

  4. A theoretical study of the coupling between a vortex-induced vibration cylindrical resonator and an electromagnetic energy harvester

    NASA Astrophysics Data System (ADS)

    Xu-Xu, J.; Barrero-Gil, A.; Velazquez, A.

    2015-11-01

    This paper presents a theoretical study of the coupling between a vortex-induced vibration (VIV) cylindrical resonator and its associated linear electromagnetic generator. The two-equation mathematical model is based on a dual-mass formulation in which the dominant masses are the stator and translator masses of the generator. The fluid-structure interaction implemented in the model equations follows the so-called ‘advanced forcing model’ whose closure relies on experimental data. The rationale to carry out the study is the fact that in these types of configurations there is a two-way interaction between the moving parts in such a way that their motions influence each other simultaneously, thereby affecting the energy actually harvested. It is believed that instead of mainly resorting to complementary numerical simulations, a theoretical model can shed some light on the nature of the interaction and, at the same time, provide scaling laws that can be used for practical design and optimization purposes. It has been found that the proposed configuration has a maximum hydrodynamic to mechanical to electrical conversion efficiency (based on the VIV resonator oscillation amplitude) of 8%. For a cylindrical resonator 10 cm long with a 2 cm diameter, this translates into an output power of 20 to 160 mW for water stream velocities in the range from 0.5 to 1 m s-1.

  5. Self supporting heat transfer element

    DOEpatents

    Story, Grosvenor Cook; Baldonado, Ray Orico

    2002-01-01

    The present invention provides an improved internal heat exchange element arranged so as to traverse the inside diameter of a container vessel such that it makes good mechanical contact with the interior wall of that vessel. The mechanical element is fabricated from a material having a coefficient of thermal conductivity above about 0.8 W cm.sup.-1.degree. K.sup.-1 and is designed to function as a simple spring member when that member has been cooled to reduce its diameter to just below that of a cylindrical container or vessel into which it is placed and then allowed to warm to room temperature. A particularly important application of this invention is directed to a providing a simple compartmented storage container for accommodating a hydrogen absorbing alloy.

  6. Cylindrical diffuser performance using a truncated plug nozzle

    NASA Technical Reports Server (NTRS)

    Galanga, F. L.; Mueller, T. J.

    1976-01-01

    Cylindrical diffuser performance for a truncated plug nozzle without external flow was tested in a blowdown wind tunnel. The nozzle was designed for an exit Mach number of 1.9 and the plug was conical in shape from the throat and converged to the axis of symmetry at an angle of 10 degrees. The diffuser section was fashioned into two 13.97 cm lengths to facilitate boring of the duct diameter and to allow for testing of two different duct lengths. A slotted hypotube was installed in the base of the diffuser to measure pressure distribution down the centerline of the diffuser. The data obtained included: the typical centerline and sidewall pressure ratio variation along the diffuser, cell pressure ratio vs overall pressure ratio for long and short diffusers and a comparison of minimum experimental cell pressure ratio vs area ratio.

  7. Palm top plasma focus device as a portable pulsed neutron source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rout, R. K.; Niranjan, Ram; Srivastava, R.

    2013-06-15

    Development of a palm top plasma focus device generating (5.2 {+-} 0.8) Multiplication-Sign 10{sup 4} neutrons/pulse into 4{pi} steradians with a pulse width of 15 {+-} 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is ofmore » 2 {mu}F capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 {mu}F, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of {sup 3}He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.« less

  8. Compact low power infrared tube furnace for in situ X-ray powder diffraction

    NASA Astrophysics Data System (ADS)

    Doran, A.; Schlicker, L.; Beavers, C. M.; Bhat, S.; Bekheet, M. F.; Gurlo, A.

    2017-01-01

    We describe the development and implementation of a compact, low power, infrared heated tube furnace for in situ powder X-ray diffraction experiments. Our silicon carbide (SiC) based furnace design exhibits outstanding thermal performance in terms of accuracy control and temperature ramping rates while simultaneously being easy to use, robust to abuse and, due to its small size and low power, producing minimal impact on surrounding equipment. Temperatures in air in excess of 1100 °C can be controlled at an accuracy of better than 1%, with temperature ramping rates up to 100 °C/s. The complete "add-in" device, minus power supply, fits in a cylindrical volume approximately 15 cm long and 6 cm in diameter and resides as close as 1 cm from other sensitive components of our experimental synchrotron endstation without adverse effects.

  9. Turbulent flow in a vessel agitated by side entering inclined blade turbine with different diameter using CFD simulation

    NASA Astrophysics Data System (ADS)

    Fathonah, N. N.; Nurtono, T.; Kusdianto; Winardi, S.

    2018-03-01

    Single phase turbulent flow in a vessel agitated by side entering inclined blade turbine has simulated using CFD. The aim of this work is to identify the hydrodynamic characteristics of a model vessel, which geometrical configuration is adopted at industrial scale. The laboratory scale model vessel is a flat bottomed cylindrical tank agitated by side entering 4-blade inclined blade turbine with impeller rotational speed N=100-400 rpm. The effect of the impeller diameter on fluid flow pattern has been investigated. The fluid flow patterns in a vessel is essentially characterized by the phenomena of macro-instabilities, i.e. the flow patterns change with large scale in space and low frequency. The intensity of fluid flow in the tank increase with the increase of impeller rotational speed from 100, 200, 300, and 400 rpm. It was accompanied by shifting the position of the core of circulation flow away from impeller discharge stream and approached the front of the tank wall. The intensity of fluid flow in the vessel increase with the increase of the impeller diameter from d=3 cm to d=4 cm.

  10. 2.43 kW narrow linewidth linearly polarized all-fiber amplifier based on mode instability suppression

    NASA Astrophysics Data System (ADS)

    Su, Rongtao; Tao, Rumao; Wang, Xiaolin; Zhang, Hanwei; Ma, Pengfei; Zhou, Pu; Xu, Xiaojun

    2017-08-01

    We demonstrate an experimental study on scaling mode instability (MI) threshold in fiber amplifiers based on fiber coiling. The experimental results show that coiling the active fiber in the cylindrical spiral shape is superior to the coiling in the plane spiral shape. When the polarization maintained Yb-doped fiber (PM YDF: with a core/inner-cladding diameter of 20/400 µm) is coiled on an aluminous plate with a bend diameter of 9-16 cm, the MI threshold is ~1.55 kW. When such a PM YDF is coiled on an aluminous cylinder with diameter of 9 cm, no MI is observed at the output power of 2.43 kW, which is limited by the available pump power. The spectral width and polarization extinction ratio is 0.255 nm and 18.3 dB, respectively, at 2.43 kW. To the best of our knowledge, this is the highest output power from a linear polarized narrow linewidth all-fiberized amplifier. By using a theoretical model, the potential MI-free scaling capability in such an amplifier is estimated to be 3.5 kW.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bazalova, M; Ahmad, M; Fahrig, R

    Purpose: To evaluate x-ray fluorescence computed tomography induced with proton beams (pXFCT) for imaging of gold contrast agent. Methods: Proton-induced x-ray fluorescence was studied by means of Monte Carlo (MC) simulations using TOPAS, a MC code based on GEANT4. First, proton-induced K-shell and L-shell fluorescence was studied as a function of proton beam energy and 1) depth in water and 2) size of contrast object. Second, pXFCT images of a 2-cm diameter cylindrical phantom with four 5- mm diameter contrast vials and of a 20-cm diameter phantom with 1-cm diameter vials were simulated. Contrast vials were filled with water andmore » water solutions with 1-5% gold per weight. Proton beam energies were varied from 70-250MeV. pXFCT sinograms were generated based on the net number of gold K-shell or L-shell x-rays determined by interpolations from the neighboring 0.5keV energy bins of spectra collected with an idealized 4π detector. pXFCT images were reconstructed with filtered-back projection, and no attenuation correction was applied. Results: Proton induced x-ray fluorescence spectra showed very low background compared to x-ray induced fluorescence. Proton induced L-shell fluorescence had a higher cross-section compared to K-shell fluorescence. Excitation of L-shell fluorescence was most efficient for low-energy protons, i.e. at the Bragg peak. K-shell fluorescence increased with increasing proton beam energy and object size. The 2% and 5% gold contrast vials were accurately reconstructed in K-shell pXFCT images of both the 2-cm and 20-cm diameter phantoms. Small phantom L-shell pXFCT image required attenuation correction and had a higher sensitivity for 70MeV protons compared to 250MeV protons. With attenuation correction, L-shell pXFCT might be a feasible option for imaging of small size (∼2cm) objects. Imaging doses for all simulations were 5-30cGy. Conclusion: Proton induced x-ray fluorescence CT promises to be an alternative quantitative imaging technique to the commonly considered XFCT imaging with x-ray beams.« less

  12. A collimated neutron detector for RFP plasmas in MST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capecchi, W. J., E-mail: capecchi@wisc.edu; Anderson, J. K.; Bonofiglo, P. J.

    The neutron emissivity profile in the Madison Symmetric Torus is being reconstructed through the use of a collimated neutron detector. A scintillator-photomultiplier tube (PMT) system is employed to detect the fusion neutrons with the plasma viewing volume defined by a 55 cm deep, 5 cm diameter aperture. Effective detection of neutrons from the viewing volume is achieved through neutron moderation using 1300 lbs of high density polyethylene shielding, which modeling predicts attenuates the penetrating flux by a factor of 10{sup 4} or more. A broad spectrum of gamma radiation is also present due to the unconfined fusion proton bombardment ofmore » the thick aluminum vacuum vessel. A 15 cm cylindrical liquid scintillator of 3.8 cm diameter is used to further increase directional sensitivity. A fast (5 ns rise time) preamplifier and digitization at 500 MHz prevent pulse pile-up even at high count rates (∼10{sup 4}/s). The entire neutron camera system is situated on an adjustable inclining base which provides the differing plasma viewing volumes necessary for reconstruction of the neutron emissivity profile. This profile, directly related to the fast-ion population, allows for an investigation of the critical fast-ion pressure gradient required to destabilize a neutral beam driven Alfvénic mode which has been shown to transport fast ions.« less

  13. Measuring Diameters Of Large Vessels

    NASA Technical Reports Server (NTRS)

    Currie, James R.; Kissel, Ralph R.; Oliver, Charles E.; Smith, Earnest C.; Redmon, John W., Sr.; Wallace, Charles C.; Swanson, Charles P.

    1990-01-01

    Computerized apparatus produces accurate results quickly. Apparatus measures diameter of tank or other large cylindrical vessel, without prior knowledge of exact location of cylindrical axis. Produces plot of inner circumference, estimate of true center of vessel, data on radius, diameter of best-fit circle, and negative and positive deviations of radius from circle at closely spaced points on circumference. Eliminates need for time-consuming and error-prone manual measurements.

  14. TH-C-19A-05: Evaluation of a New Reusable 3D Dosimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juang, T; Adamovics, J; Oldham, M

    Purpose: PRESAGE is a radiochromic plastic which has demonstrated strong potential for high resolution single-use 3D dosimetry. This study evaluates a new PRESAGE formulation (Presage-RU) in which the radiochromic response is reversible (the dosimeter optically clears after irradiation), enabling the potential for reusability. Methods: Presage-RU dose response and optical-clearing rates were evaluated in both small volume dosimeters (1×1×4.5cm) and a larger cylindrical dosimeter (8cm diameter, 4.5cm length). All dosimeters were allowed to fully optically clear in dark, room temperature conditions between irradiations. Dose response was determined by irradiating small volume samples from 0–8.0Gy and measuring change in optical density. Themore » cylindrical dosimeter was irradiated with a simple 4-field box plan (parallel opposed pairs of 4cm×4cm AP-PA beams and 2cm×4cm lateral beams) to 20Gy. High resolution 3D dosimetry was achieved utilizing optical-CT readout. Readings were tracked up to 14 days to characterize optical clearing. Results: Initial irradiation yielded a response of 0.0119△OD/(Gy*cm) while two subsequent reirradiations yielded a lower but consistent response of 0.0087△OD/(Gy*cm). Strong linearity of dose response was observed for all irradiations. In the large cylindrical dosimeter, the integral dose within the high dose region exhibited an exponential decay in signal over time (halflife= 23.9 hours), with the dosimeter effectively cleared (0.04% of the initial signal) after 10 days. Subsequent irradiation resulted in 19.5% lower initial signal but demonstrated that the exponential clearing rate remained consistent. Results of additional subsequent irradiations will also be presented. Conclusion: This work introduces a new re-usable radiochromic dosimeter (Presage-RU) compatible with high resolution (sub-millimeter) 3D dosimetry. Sensitivity of the initial radiation was observed to be slightly higher than subsequent irradiations, but the clearing time remained constant, indicating the dosimeter can be re-used after 10 days. Presage-RU has potential to dramatically improve cost-effectiveness and thereby lower the barrier for implementing comprehensive, high resolution 3D dosimetry. John Adamovics is the president of Heuris Inc., which commercializes PRESAGE.« less

  15. Quantitative three-dimensional dynamic imaging of structure and function of the cardiopulmonary and circulatory systems in all regions of the body

    NASA Technical Reports Server (NTRS)

    Sturm, R. E.; Ritman, E. L.; Wood, E. H.

    1975-01-01

    The background for, and design of a third generation, general purpose, all electronic spatial scanning system, the DSR is described. Its specified performance capabilities provide dynamic and stop action three dimensional spatial reconstructions of any portion of the body based on a minimum exposure time of 0.01 second for each 28 multiplanar 180 deg scanning set, a maximum scan repetition rate of sixty 28 multiplane scan sets per second, each scan set consisting of a maximum of 240 parallel cross sections of a minimum thickness of 0.9 mm, and encompassing a maximum cylindrical volume about 23 cm in length and up to 38 cm in diameter.

  16. J-PET: A New Technology for the Whole-body PET Imaging

    NASA Astrophysics Data System (ADS)

    Niedźwiecki, S.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kapłon, Ł.; Kisielewska-Kamińska, D.; Korcyl, G.; Kowalski, P.; Kozik, T.; Krawczyk, N.; Krzemień, W.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Pałka, M.; Raczyński, L.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Shopa, R. Y.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.

    The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.

  17. SU-F-18C-11: Diameter Dependency of the Radial Dose Distribution in a Long Polyethylene Cylinder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakalyar, D; McKenney, S; Feng, W

    Purpose: The radial dose distribution in the central plane of a long cylinder following a long CT scan depends upon the diameter and composition of the cylinder. An understanding of this behavior is required for determining the spatial average of the dose in the central plane. Polyethylene, the material for construction of the TG200/ICRU phantom (30 cm in diameter) was used for this study. Size effects are germane to the principles incorporated in size specific dose estimates (SSDE); thus diameter dependency was explored as well. Method: ssuming a uniform cylinder and cylindrically symmetric conditions of irradiation, the dose distribution canmore » be described using a radial function. This function must be an even function of the radial distance due to the conditions of symmetry. Two effects are accounted for: The direct beam makes its weakest contribution at the center while the contribution due to scatter is strongest at the center and drops off abruptly at the outer radius. An analytic function incorporating these features was fit to Monte Carlo results determined for infinite polyethylene cylinders of various diameters. A further feature of this function is that it is integrable. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. The competing effects described above can Resultin an absolute maximum occurring between the center and outer edge of the cylinders. For the smallest cylinders, the maximum dose may occur at the center. Conclusion: An integrable, analytic function can be used to characterize the radial dependency of dose for cylindrical CT phantoms of various sizes. One use for this is to help determine average dose distribution over the central cylinder plane when equilibrium dose has been reached.« less

  18. Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source.

    PubMed

    Manohar, Nivedh; Reynoso, Francisco J; Cho, Sang Hyun

    2013-08-01

    To develop a proof-of-principle L-shell x-ray fluorescence (XRF) imaging system that locates and quantifies sparse concentrations of gold nanoparticles (GNPs) using a benchtop polychromatic x-ray source and a silicon (Si)-PIN diode x-ray detector system. 12-mm-diameter water-filled cylindrical tubes with GNP concentrations of 20, 10, 5, 0.5, 0.05, 0.005, and 0 mg∕cm3 served as calibration phantoms. An imaging phantom was created using the same cylindrical tube but filled with tissue-equivalent gel containing structures mimicking a GNP-loaded blood vessel and approximately 1 cm3 tumor. Phantoms were irradiated by a 3-mm-diameter pencil-beam of 62 kVp x-rays filtered by 1 mm aluminum. Fluorescence∕scatter photons from phantoms were detected at 90° with respect to the beam direction using a Si-PIN detector placed behind a 2.5-mm-diameter lead collimator. The imaging phantom was translated horizontally and vertically in 0.3-mm steps to image a 6 mm×15 mm region of interest (ROI). For each phantom, the net L-shell XRF signal from GNPs was extracted from background, and then corrected for detection efficiency and in-phantom attenuation using a fluorescence-to-scatter normalization algorithm. XRF measurements with calibration phantoms provided a calibration curve showing a linear relationship between corrected XRF signal and GNP mass per imaged voxel. Using the calibration curve, the detection limit (at the 95% confidence level) of the current experimental setup was estimated to be a GNP mass of 0.35 μg per imaged voxel (1.73×10(-2) cm3). A 2D XRF map of the ROI was also successfully generated, reasonably matching the known spatial distribution as well as showing the local variation of GNP concentrations. L-shell XRF imaging can be a highly sensitive tool that has the capability of simultaneously imaging the spatial distribution and determining the local concentration of GNPs presented on the order of parts-per-million level within subcentimeter-sized ex vivo samples and superficial tumors during preclinical animal studies.

  19. Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source

    PubMed Central

    Manohar, Nivedh; Reynoso, Francisco J.; Cho, Sang Hyun

    2013-01-01

    Purpose: To develop a proof-of-principle L-shell x-ray fluorescence (XRF) imaging system that locates and quantifies sparse concentrations of gold nanoparticles (GNPs) using a benchtop polychromatic x-ray source and a silicon (Si)-PIN diode x-ray detector system. Methods: 12-mm-diameter water-filled cylindrical tubes with GNP concentrations of 20, 10, 5, 0.5, 0.05, 0.005, and 0 mg/cm3 served as calibration phantoms. An imaging phantom was created using the same cylindrical tube but filled with tissue-equivalent gel containing structures mimicking a GNP-loaded blood vessel and approximately 1 cm3 tumor. Phantoms were irradiated by a 3-mm-diameter pencil-beam of 62 kVp x-rays filtered by 1 mm aluminum. Fluorescence/scatter photons from phantoms were detected at 90° with respect to the beam direction using a Si-PIN detector placed behind a 2.5-mm-diameter lead collimator. The imaging phantom was translated horizontally and vertically in 0.3-mm steps to image a 6 mm × 15 mm region of interest (ROI). For each phantom, the net L-shell XRF signal from GNPs was extracted from background, and then corrected for detection efficiency and in-phantom attenuation using a fluorescence-to-scatter normalization algorithm. Results: XRF measurements with calibration phantoms provided a calibration curve showing a linear relationship between corrected XRF signal and GNP mass per imaged voxel. Using the calibration curve, the detection limit (at the 95% confidence level) of the current experimental setup was estimated to be a GNP mass of 0.35 μg per imaged voxel (1.73 × 10−2 cm3). A 2D XRF map of the ROI was also successfully generated, reasonably matching the known spatial distribution as well as showing the local variation of GNP concentrations. Conclusions:L-shell XRF imaging can be a highly sensitive tool that has the capability of simultaneously imaging the spatial distribution and determining the local concentration of GNPs presented on the order of parts-per-million level within subcentimeter-sized ex vivo samples and superficial tumors during preclinical animal studies. PMID:23927295

  20. Technique for fabrication of ultrathin foils in cylindrical geometry for liner-plasma implosion experiments with sub-megaampere currents

    DOE PAGES

    Yager-Elorriaga, D. A.; Steiner, A. M.; Patel, S. G.; ...

    2015-11-19

    In this study, we describe a technique for fabricating ultrathin foils in cylindrical geometry for liner-plasma implosion experiments using sub-MA currents. Liners are formed by wrapping a 400 nm, rectangular strip of aluminum foil around a dumbbell-shaped support structure with a non-conducting center rod, so that the liner dimensions are 1 cm in height, 6.55 mm in diameter, and 400 nm in thickness. The liner-plasmas are imploded by discharging ~600 kA with ~200 ns rise time using a 1 MA linear transformer driver, and the resulting implosions are imaged four times per shot using laser-shadowgraphy at 532 nm. As amore » result, this technique enables the study of plasma implosion physics, including the magneto Rayleigh-Taylor, sausage, and kink instabilities on initially solid, imploding metallic liners with university-scale pulsed power machines.« less

  1. Lineal energy calibration of mini tissue-equivalent gas-proportional counters (TEPC)

    NASA Astrophysics Data System (ADS)

    Conte, V.; Moro, D.; Grosswendt, B.; Colautti, P.

    2013-07-01

    Mini TEPCs are cylindrical gas proportional counters of 1 mm or less of sensitive volume diameter. The lineal energy calibration of these tiny counters can be performed with an external gamma-ray source. However, to do that, first a method to get a simple and precise spectral mark has to be found and then the keV/μm value of this mark. A precise method (less than 1% of uncertainty) to identify this markis described here, and the lineal energy value of this mark has been measured for different simulated site sizes by using a 137Cs gamma source and a cylindrical TEPC equipped with a precision internal 244Cm alpha-particle source, and filled with propane-based tissue-equivalent gas mixture. Mini TEPCs can be calibrated in terms of lineal energy, by exposing them to 137Cesium sources, with an overall uncertainty of about 5%.

  2. Technique for fabrication of ultrathin foils in cylindrical geometry for liner-plasma implosion experiments with sub-megaampere currents

    NASA Astrophysics Data System (ADS)

    Yager-Elorriaga, D. A.; Steiner, A. M.; Patel, S. G.; Jordan, N. M.; Lau, Y. Y.; Gilgenbach, R. M.

    2015-11-01

    In this work, we describe a technique for fabricating ultrathin foils in cylindrical geometry for liner-plasma implosion experiments using sub-MA currents. Liners are formed by wrapping a 400 nm, rectangular strip of aluminum foil around a dumbbell-shaped support structure with a non-conducting center rod, so that the liner dimensions are 1 cm in height, 6.55 mm in diameter, and 400 nm in thickness. The liner-plasmas are imploded by discharging ˜600 kA with ˜200 ns rise time using a 1 MA linear transformer driver, and the resulting implosions are imaged four times per shot using laser-shadowgraphy at 532 nm. This technique enables the study of plasma implosion physics, including the magneto Rayleigh-Taylor, sausage, and kink instabilities on initially solid, imploding metallic liners with university-scale pulsed power machines.

  3. Technique for fabrication of ultrathin foils in cylindrical geometry for liner-plasma implosion experiments with sub-megaampere currents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yager-Elorriaga, D. A.; Steiner, A. M.; Patel, S. G.

    In this study, we describe a technique for fabricating ultrathin foils in cylindrical geometry for liner-plasma implosion experiments using sub-MA currents. Liners are formed by wrapping a 400 nm, rectangular strip of aluminum foil around a dumbbell-shaped support structure with a non-conducting center rod, so that the liner dimensions are 1 cm in height, 6.55 mm in diameter, and 400 nm in thickness. The liner-plasmas are imploded by discharging ~600 kA with ~200 ns rise time using a 1 MA linear transformer driver, and the resulting implosions are imaged four times per shot using laser-shadowgraphy at 532 nm. As amore » result, this technique enables the study of plasma implosion physics, including the magneto Rayleigh-Taylor, sausage, and kink instabilities on initially solid, imploding metallic liners with university-scale pulsed power machines.« less

  4. Ion-Acoustic Wave-Particle Energy Flow Rates

    NASA Astrophysics Data System (ADS)

    Berumen, Jorge; Chu, Feng; Hood, Ryan; Mattingly, Sean; Skiff, Fred

    2017-10-01

    We present an experimental characterization of the energy flow rates for ion acoustic waves. The experiment is performed in a cylindrical, magnetized, singly-ionized Argon, inductively-coupled gas discharge plasma that is weakly collisional with typical conditions: n 109cm-3 Te 9 eV and B 660 kG. A 4 ring antenna with diameter similar to the plasma diameter is used for launching the waves. A survey of the zeroth and first order ion velocity distribution functions (IVDF) is done using Laser-Induced Fluorescence (LIF) as the main diagnostics method. Using these IVDFs along with Vlasov's equation the different energy rates are measured for different values of ion velocity and separation from the antenna. We would like to acknowledge DOE DE-FG02-99ER54543 for their financial support throughout this research.

  5. Development of a vector-tensor system to measure the absolute magnetic flux density and its gradient in magnetically shielded rooms.

    PubMed

    Voigt, J; Knappe-Grüneberg, S; Gutkelch, D; Haueisen, J; Neuber, S; Schnabel, A; Burghoff, M

    2015-05-01

    Several experiments in fundamental physics demand an environment of very low, homogeneous, and stable magnetic fields. For the magnetic characterization of such environments, we present a portable SQUID system that measures the absolute magnetic flux density vector and the gradient tensor. This vector-tensor system contains 13 integrated low-critical temperature (LTc) superconducting quantum interference devices (SQUIDs) inside a small cylindrical liquid helium Dewar with a height of 31 cm and 37 cm in diameter. The achievable resolution depends on the flux density of the field under investigation and its temporal drift. Inside a seven-layer mu-metal shield, an accuracy better than ±23 pT for the components of the static magnetic field vector and ±2 pT/cm for each of the nine components of the gradient tensor is reached by using the shifting method.

  6. Development of a vector-tensor system to measure the absolute magnetic flux density and its gradient in magnetically shielded rooms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voigt, J.; Knappe-Grüneberg, S.; Gutkelch, D.

    2015-05-15

    Several experiments in fundamental physics demand an environment of very low, homogeneous, and stable magnetic fields. For the magnetic characterization of such environments, we present a portable SQUID system that measures the absolute magnetic flux density vector and the gradient tensor. This vector-tensor system contains 13 integrated low-critical temperature (LTc) superconducting quantum interference devices (SQUIDs) inside a small cylindrical liquid helium Dewar with a height of 31 cm and 37 cm in diameter. The achievable resolution depends on the flux density of the field under investigation and its temporal drift. Inside a seven-layer mu-metal shield, an accuracy better than ±23more » pT for the components of the static magnetic field vector and ±2 pT/cm for each of the nine components of the gradient tensor is reached by using the shifting method.« less

  7. Experimental and Numerical Investigation of Adsorption/Desorption in Packed Sorption Beds Under Ideal and Non-Ideal Flows

    NASA Technical Reports Server (NTRS)

    Mohamadinejad, H.; Knox, J. C.; Smith, James E.

    1999-01-01

    The importance of the wall effect on packed beds in the adsorption and desorption of carbon dioxide, nitrogen, and water on molecular sieve 5A of 0.127 cm in radius is examined experimentally and with one-dimensional computer simulations. Experimental results are presented for a 22.5-cm long by 4.5-cm diameter cylindrical column with concentration measurements taken at various radial locations. The set of partial differential equations are solved using finite differences and Newman's method. Comparison of test data with the axial-dispersed, non-isothermal, linear driving force model suggests that a two-dimensional model (submitted to Separation Science and Technology) is required for accurate simulation of the average column breakthrough concentration. Additional comparisons of test data with the model provided information on the interactive effects of carrier gas coadsorption with CO2, as well as CO2-H2O interactions.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brualla, Lorenzo, E-mail: lorenzo.brualla@uni-due.de; Zaragoza, Francisco J.; Sempau, Josep

    Purpose: External beam radiotherapy is the only conservative curative approach for Stage I non-Hodgkin lymphomas of the conjunctiva. The target volume is geometrically complex because it includes the eyeball and lid conjunctiva. Furthermore, the target volume is adjacent to radiosensitive structures, including the lens, lacrimal glands, cornea, retina, and papilla. The radiotherapy planning and optimization requires accurate calculation of the dose in these anatomical structures that are much smaller than the structures traditionally considered in radiotherapy. Neither conventional treatment planning systems nor dosimetric measurements can reliably determine the dose distribution in these small irradiated volumes. Methods and Materials: The Montemore » Carlo simulations of a Varian Clinac 2100 C/D and human eye were performed using the PENELOPE and PENEASYLINAC codes. Dose distributions and dose volume histograms were calculated for the bulbar conjunctiva, cornea, lens, retina, papilla, lacrimal gland, and anterior and posterior hemispheres. Results: The simulated results allow choosing the most adequate treatment setup configuration, which is an electron beam energy of 6 MeV with additional bolus and collimation by a cerrobend block with a central cylindrical hole of 3.0 cm diameter and central cylindrical rod of 1.0 cm diameter. Conclusions: Monte Carlo simulation is a useful method to calculate the minute dose distribution in ocular tissue and to optimize the electron irradiation technique in highly critical structures. Using a voxelized eye phantom based on patient computed tomography images, the dose distribution can be estimated with a standard statistical uncertainty of less than 2.4% in 3 min using a computing cluster with 30 cores, which makes this planning technique clinically relevant.« less

  9. Electron beam charging and arc discharging of spacecraft insulating materials

    NASA Technical Reports Server (NTRS)

    Balmain, K. G.

    1983-01-01

    Samples of Mylar and Teflon film were exposed to combinations of monoenergetic electron and lithium ion fluxes in various ratios. The samples' discharge rates and strengths were found to diminish as the ion proportion increased. Various types of capacitors were exposed in air to beta irradiation from a 100 mCie Strontium-90 radioisotope source located at distances ranging from 2 cm to 5 cm from the capacitors. In these preliminary experiments, no evidence of spontaneous electrical breakdown was noted, nor was any change in RF impedance detectable using the available instrumentation. A decrease in DC resistance was noted, apparently due to radiation-induced conductivity. A cylindrical glass vacuum chamber is being assembled. Its inside dimensions are 44 cm diameter by 100 cm length. All necessary associated components and instruments have been acquired, including electron and ion guns, Trek surface potential probe and turbo-molecular pump. A mass-spectrometer detector for leaks and evolved gases will be ordered shortly.

  10. A Comparison of Four-Image Reconstruction Algorithms for 3-D PET Imaging of MDAPET Camera Using Phantom Data

    NASA Astrophysics Data System (ADS)

    Baghaei, H.; Wong, Wai-Hoi; Uribe, J.; Li, Hongdi; Wang, Yu; Liu, Yaqiang; Xing, Tao; Ramirez, R.; Xie, Shuping; Kim, Soonseok

    2004-10-01

    We compared two fully three-dimensional (3-D) image reconstruction algorithms and two 3-D rebinning algorithms followed by reconstruction with a two-dimensional (2-D) filtered-backprojection algorithm for 3-D positron emission tomography (PET) imaging. The two 3-D image reconstruction algorithms were ordered-subsets expectation-maximization (3D-OSEM) and 3-D reprojection (3DRP) algorithms. The two rebinning algorithms were Fourier rebinning (FORE) and single slice rebinning (SSRB). The 3-D projection data used for this work were acquired with a high-resolution PET scanner (MDAPET) with an intrinsic transaxial resolution of 2.8 mm. The scanner has 14 detector rings covering an axial field-of-view of 38.5 mm. We scanned three phantoms: 1) a uniform cylindrical phantom with inner diameter of 21.5 cm; 2) a uniform 11.5-cm cylindrical phantom with four embedded small hot lesions with diameters of 3, 4, 5, and 6 mm; and 3) the 3-D Hoffman brain phantom with three embedded small hot lesion phantoms with diameters of 3, 5, and 8.6 mm in a warm background. Lesions were placed at different radial and axial distances. We evaluated the different reconstruction methods for MDAPET camera by comparing the noise level of images, contrast recovery, and hot lesion detection, and visually compared images. We found that overall the 3D-OSEM algorithm, especially when images post filtered with the Metz filter, produced the best results in terms of contrast-noise tradeoff, and detection of hot spots, and reproduction of brain phantom structures. Even though the MDAPET camera has a relatively small maximum axial acceptance (/spl plusmn/5 deg), images produced with the 3DRP algorithm had slightly better contrast recovery and reproduced the structures of the brain phantom slightly better than the faster 2-D rebinning methods.

  11. TH-CD-207B-10: Effect of CT Reconstruction Filter On Measured Hounsfield Values in Lung Nodules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, K; Reiser, I; Sanchez, A

    Purpose: Measured Hounsfield numbers in CT are used by radiologists to determine the presence of calcium or fat in lung nodules, either of which suggests a benign diagnosis. However, substantial variations in Hounsfield number may arise due to the use of different reconstruction parameters such as the filter/kernel, leading to measurement inaccuracies. This quality improvement project was developed to demonstrate measurement pitfalls and to identify acceptable conditions for incorporating Hounsfield values as a factor in lung nodule diagnosis. Methods: 12 mm-diameter spheres of polyurethane and urethane foam were placed into an anthropomorphic chest phantom, and 10 mm-diameter tubes with varyingmore » iodine concentrations were placed into a 16 cm PMMA cylindrical phantom. Additionally, 11 mm-diameter PMMA and HDPE spheres were placed in a 10 cm PMMA cylindrical phantom. Phantoms were scanned at 120 kVp using a Siemens Biograph mCT and on a Philips iCT and reconstructed using various reconstruction filters. Results: For the Siemens system, both sharp kernels and smooth kernels altered the Hounsfield numbers. Hounsfield numbers varied within a range of 8.9 HU for urethane foam and varied within 58.7 HU for polyurethane. The iodine measurements varied up to 37.9 HU for the lowest concentration. For the Philips system, Hounsfield numbers were relatively consistent but were higher for the “Detail” and “Lung Enhanced” filters, varying by 36.9 HU for PMMA and 15.9 HU for HDPE. Conclusion: Reconstruction filters can change the measured Hounsfield numbers of nodular objects, especially with detail-enhancing (sharpening) filters commonly used in lung imaging. Measured values should only be used for diagnostic decision support with filters that have demonstrated accuracy and consistency. While filter accuracy statements are available from manufacturers, radiologists are likely not aware of the extent of potential variations that can occur in a clinical setting.« less

  12. Lateral mode coupling to reduce the electrical impedance of small elements required for high power ultrasound therapy phased arrays.

    PubMed

    Hynynen, Kullervo; Yin, Jianhua

    2009-03-01

    A method that uses lateral coupling to reduce the electrical impedance of small transducer elements in generating ultrasound waves was tested. Cylindrical, radially polled transducer elements were driven at their length resonance frequency. Computer simulation and experimental studies showed that the electrical impedance of the transducer element could be controlled by the cylinder wall thickness, while the operation frequency was determined by the cylinder length. Acoustic intensity (averaged over the cylinder diameter) over 10 W / cm(2) (a therapeutically relevant intensity) was measured from these elements.

  13. Standard reference materials: Thermal conductivity of electrolytic iron, SRM 734, from 4 to 300 K

    NASA Technical Reports Server (NTRS)

    Hust, J. G.; Sparks, L. L.

    1971-01-01

    Thermal conductivity data were obtained by the axial one-dimensional heat flow method for a cylindrical rod 3.6 mm in diameter and 23 cm long with an electric heater at one end and a temperature controlled sink at the other. Variability of this iron was studied by means of electrical residual resistivity ratio measurements on 63 specimens. This study showed that with a two-hour anneal at 1000 C one can obtain a thermal conductivity Standard Reference Material that has variability of less than 1% in thermal conductivity.

  14. A Large Tracking Detector In Vacuum Consisting Of Self-Supporting Straw Tubes

    NASA Astrophysics Data System (ADS)

    Wintz, P.

    2004-02-01

    A novel technique to stretch the anode wire simply by the gas over-pressure inside straw drift tubes reduces the necessary straw weight to an absolute minimum. Our detector will consist of more than 3000 straws filling up a cylindrical tracking volume of 1m diameter and 30cm length. The projected spatial resolution is 200μm. The detector with a total mass of less than 15kg will be operated in vacuum, but will have an added wall thickness of 3mm mylar, only. The detector design, production experience and first results will be discussed.

  15. Propagation of detonation wave in hydrogen-air mixture in channels with sound-absorbing surfaces

    NASA Astrophysics Data System (ADS)

    Bivol, G. Yu.; Golovastov, S. V.; Golub, V. V.

    2015-12-01

    The possibility of using sound-absorbing surfaces for attenuating the intensity of detonation waves propagating in hydrogen-air mixtures has been experimentally studied in a cylindrical detonation tube open at one end, with an explosive initiated by spark discharge at the closed end. Sound-absorbing elements were made of an acoustic-grade foamed rubber with density of 0.035 g/cm3 containing open pores with an average diameter of 0.5 mm. The degree of attenuation of the detonation wave front velocity was determined as dependent on the volume fraction of hydrogen in the gas mixture.

  16. Correlation of windage-loss data for a Lundell alternator

    NASA Technical Reports Server (NTRS)

    Kempke, E. E., Jr.; Gorland, S. H.

    1972-01-01

    Viscous torque (windage) of a Lundell-shaped rotor having a major diameter of 20.3 cm (8 in.) rotating within a concentric housing was measured at speeds up to 36,000 rpm. The center cylindrical section of the housing was tested with both a smooth surface and axial slots to simulate alternator winding slots. For concentric cylinders, the range of Reynolds numbers was extended to 70,000. Three radial clearances, 1, 2, and 4 mm (0.04, 0.08, and 0.16in.), corresponding to 1, 2, and 4 percent of the rotor radius, were tested.

  17. Effects of Shell-Buckling Knockdown Factors in Large Cylindrical Shells

    NASA Technical Reports Server (NTRS)

    Hrinda, Glenn A.

    2012-01-01

    Shell-buckling knockdown factors (SBKF) have been used in large cylindrical shell structures to account for uncertainty in buckling loads. As the diameter of the cylinder increases, achieving the manufacturing tolerances becomes increasingly more difficult. Knockdown factors account for manufacturing imperfections in the shell geometry by decreasing the allowable buckling load of the cylinder. In this paper, large-diameter (33 ft) cylinders are investigated by using various SBKF's. An investigation that is based on finite-element analysis (FEA) is used to develop design sensitivity relationships. Different manufacturing imperfections are modeled into a perfect cylinder to investigate the effects of these imperfections on buckling. The analysis results may be applicable to large- diameter rockets, cylindrical tower structures, bulk storage tanks, and silos.

  18. SU-G-IeP4-04: DD-Neutron Source Collimation for Neutron Stimulated Emission Computed Tomography: A Monte Carlo Simulation Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fong, G; Kapadia, A

    Purpose: To optimize collimation and shielding for a deuterium-deuterium (DD) neutron generator for an inexpensive and compact clinical neutron imaging system. The envisioned application is cancer diagnosis through Neutron Stimulated Emission Computed Tomography (NSECT). Methods: Collimator designs were tested with an isotropic 2.5 MeV neutron source through GEANT4 simulations. The collimator is a 52×52×52 cm{sup 3} polyethylene block coupled with a 1 cm lead sheet in sequence. Composite opening was modeled into the collimator to permit passage of neutrons. The opening varied in shape (cylindrical vs. tapered), size (1–5 cm source-side and target-side openings) and aperture placements (13–39 cm frommore » source-side). Spatial and energy distribution of neutrons and gammas were tracked from each collimator design. Parameters analyzed were primary beam width (FWHM), divergence, and efficiency (percent transmission) for different configurations of the collimator. Select resultant outputs were then used for simulated NSECT imaging of a virtual breast phantom containing a 2.5 cm diameter tumor to assess the effect of the collimator on spatial resolution, noise, and scan time. Finally, composite shielding enclosure made of polyethylene and lead was designed and evaluated to block 99.99% of neutron and gamma radiation generated in the system. Results: Analysis of primary beam indicated the beam-width is linear to the aperture size. Increasing source-side opening allowed at least 20% more neutron throughput for all designs relative to the cylindrical openings. Maximum throughput for all designs was 364% relative to cylindrical openings. Conclusion: The work indicates potential for collimating and shielding a DD neutron generator for use in a clinical NSECT system. The proposed collimator designs produced a well-defined collimated neutron beam that can be used to image samples of interest with millimeter resolution. Balance in output efficiency, noise reduction, and scan time should be considered to determine the optimal design for specific NSECT applications.« less

  19. Measurement And Calculation of High-Energy Neutron Spectra Behind Shielding at the CERF 120-GeV/C Hadron Beam Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakao, N.; /SLAC; Taniguchi, S.

    Neutron energy spectra were measured behind the lateral shield of the CERF (CERN-EU High Energy Reference Field) facility at CERN with a 120 GeV/c positive hadron beam (a mixture of mainly protons and pions) on a cylindrical copper target (7-cm diameter by 50-cm long). An NE213 organic liquid scintillator (12.7-cm diameter by 12.7-cm long) was located at various longitudinal positions behind shields of 80- and 160-cm thick concrete and 40-cm thick iron. The measurement locations cover an angular range with respect to the beam axis between 13 and 133{sup o}. Neutron energy spectra in the energy range between 32 MeVmore » and 380 MeV were obtained by unfolding the measured pulse height spectra with the detector response functions which have been verified in the neutron energy range up to 380 MeV in separate experiments. Since the source term and experimental geometry in this experiment are well characterized and simple and results are given in the form of energy spectra, these experimental results are very useful as benchmark data to check the accuracies of simulation codes and nuclear data. Monte Carlo simulations of the experimental set up were performed with the FLUKA, MARS and PHITS codes. Simulated spectra for the 80-cm thick concrete often agree within the experimental uncertainties. On the other hand, for the 160-cm thick concrete and iron shield differences are generally larger than the experimental uncertainties, yet within a factor of 2. Based on source term simulations, observed discrepancies among simulations of spectra outside the shield can be partially explained by differences in the high-energy hadron production in the copper target.« less

  20. Inward electrostatic precipitation of interplanetary particles

    NASA Technical Reports Server (NTRS)

    Rulison, Aaron J.; Flagan, Richard C.; Ahrens, Thomas J.

    1993-01-01

    An inward precipitator collects particles initially dispersed in a gas throughout either a cylindrical or spherical chamber onto a small central planchet. The instrument is effective for particle diameters greater than about 1 micron. One use is the collection of interplanetary dust particles (IDPs) which are stopped in a noble gas (xenon) by drag and ablation after perforating the wall of a thin-walled spacecraft-mounted chamber. First, the particles are positively charged for several seconds by the corona production of positive xenon ions from inward facing needles placed on the chamber wall. Then an electric field causes the particles to migrate toward the center of the instrument and onto the planchet. The collection time (on the order of hours for a 1 m radius spherical chamber) is greatly reduced by the use of optimally located screens which reapportion the electric field. Some of the electric field lines terminate on the wires of the screens so a fraction of the total number of particles in the chamber is lost. The operation of the instrument is demonstrated by experiments which show the migration of carbon soot particles with radius of approximately 1 micron in a 5 cm diameter cylindrical chamber with a single field enhancing screen toward a 3.2 mm central collection rod.

  1. Electron Bernstein Wave Studies in MST

    NASA Astrophysics Data System (ADS)

    Seltzman, Andrew; Anderson, Jay; Forest, Cary; Nonn, Paul; Thomas, Mark; Almagri, Abdulgader; Chapman, Brett; Dubois, Ami; Goetz, John; McCollam, Karsten

    2015-11-01

    The RFP plasma is inaccessible to ECRH, requiring the electron Bernstein wave (EBW) for edge localized heating and current drive. MST is capable of generating RFPs or overdense tokamaks with Bt(0) ~ 0.08-0.14T in which a 5.55 GHz RF source (450kW, 2ms pulse) can heat at fundamental and harmonic EC resonances. The design of a suitable antenna is challenging in the RFP due to a magnetic field geometry that requires a low-field-side launch. The small vacuum gap between the close-fitting conducting shell and plasma leads to substantial antenna-plasma interaction. A minimized port hole size is required to limit error fields. Even so the port hole induced magnetic field perturbation in the antenna near-field that affects the mode conversion process and introduces EC resonances. A 5cm diameter cylindrical antenna centered in 5cm and 11cm diameter portholes is used. A multi-chord time-resolved x-ray detector and GENRAY ray tracing verifies EBW heating at higher harmonics in an MST tokamak with 10-40keV detected x-ray energies. Evidence of RF-induced emission from absorption at higher harmonics (4th / 5th) in low current RFP discharges has been observed. Simultaneous reflected power changes correspond to termination of x-ray emission indicating power limits. Work supported by USDOE.

  2. A study of cylindrical Hall thruster for low power space applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Y. Raitses; N.J. Fisch; K.M. Ertmer

    2000-07-27

    A 9 cm cylindrical thruster with a ceramic channel exhibited performance comparable to the state-of-the-art Hall thrusters at low and moderate power levels. Significantly, its operation is not accompanied by large amplitude discharge low frequency oscillations. Preliminary experiments on a 2 cm cylindrical thruster suggest the possibility of a high performance micro Hall thruster.

  3. Characterization of Briquette from the Corncob Charcoal and Sago Stem Alloys

    NASA Astrophysics Data System (ADS)

    Lestari, Lina; Inda Variani, Viska; Nyoman Sudiana, I.; Purnama Sari, Dewi; Ode Sitti Ilmawati, Wa; Sahaluddin Hasan, Erzam

    2017-05-01

    The briquettes fabricated from charcoal of corncob (zea mays,L) and sago stem (metroxilon sago rottb) have been produced and characterized. The samples were prepared step by step carefully. The charcoal powder filtered by strainer with mesh size of 70-80 to get the homogeneous particle size. Briquettes are made by mixing corncob charcoal powder, sago stem charcoal and sago adhesive with a mass ratio of 4:5:1, 4.5: 4.5: 1, 5:4:1. The materials are mixed with hot water and stirred to get homogeneous blend. Then they are compacted by pressure of 34.66kg/cm2, 69.32kg/cm2, and 103.98kg/cm2 to form a cylindrical shape with diameter of 4 cm. The cylindrical briquettes then were dried at temperature of 60°C for 48 hours. After dried, the samples where then characterized their density and water, ash, volatile matter, fixed carbon contents. The burning rate, combustion temperature, and ignition time were also determined. The experimental results show that the briquettes have average densities from 0.602 to 0.717gr/cm3. The density increase with the increasing of forming pressure. The increasing of pressure also result in the decreasing of moisture content from 2.669% to 0.842%. The ash content is found from 3.459% to 8.766%. Volatile matter and fixed carbon are varies from 13.658% and 21.168% and 67.667% to 80.758% respectively. The lowest burning rate is 0.0898gr/s and the optimum burning temperature is 499.2°C with the lowest ignition time of 1.58 minutes. These briquette’s parameters agree wit the quality standard of industrial briquette.

  4. TU-CD-207-10: Dedicated Cone-Beam Breast CT: Design of a 3-D Beam-Shaping Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vedantham, S; Shi, L; Karellas, A

    2015-06-15

    Purpose: To design a 3 -D beam-shaping filter for cone-beam breast CT for equalizing x-ray photon fluence incident on the detector along both fan and cone angle directions. Methods: The 3-D beam-shaping filter was designed as the sum of two filters: a bow-tie filter assuming cylindrical breast and a 3D difference filter equivalent to the difference in projected thickness between the cylinder and the real breast. Both filters were designed with breast-equivalent material and converted to Al for the targeted x-ray spectrum. The bow-tie was designed for the largest diameter cylindrical breast by determining the fan-angle dependent path-length and themore » filter thickness needed to equalize the fluence. A total of 23,760 projections (180 projections of 132 binary breast CT volumes) were averaged, scaled for the largest breast, and subtracted from the projection of the largest diameter cylindrical breast to provide the 3D difference filter. The 3 -D beam shaping filter was obtained by summing the two filters. Numerical simulations with semi-ellipsoidal breasts of 10–18 cm diameter (chest-wall to nipple length=0.75 x diameter) were conducted to evaluate beam equalization. Results: The proposed 3-D beam-shaping filter showed a 140% -300% improvement in equalizing the photon fluence along the chest-wall to nipple (cone-angle) direction compared to a bow-tie filter. The improvement over bow-tie filter was larger for breasts with longer chest-wall to nipple length. Along the radial (fan-angle) direction, the performance of the 3-D beam shaping filter was marginally better than the bow-tie filter, with 4%-10% improvement in equalizing the photon fluence. For a ray traversing the chest-wall diameter of the breast, the filter transmission ratio was >0.95. Conclusion: The 3-D beam shaping filter provided substantial advantage over bow-tie filter in equalizing the photon fluence along the cone-angle direction. In conjunction with a 2-axis positioner, the filter can accommodate breasts of varying dimensions and chest-wall inclusion. Supported in part by NIH R01 CA128906 and R21 CA134128. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.« less

  5. Numerical and experimental study on buckling and postbuckling behavior of cracked cylindrical shells

    NASA Astrophysics Data System (ADS)

    Saemi, J.; Sedighi, M.; Shariati, M.

    2015-09-01

    The effect of crack on load-bearing capacity and buckling behavior of cylindrical shells is an essential consideration in their design. In this paper, experimental and numerical buckling analysis of steel cylindrical shells of various lengths and diameters with cracks have been studied using the finite element method, and the effect of crack position, crack orientation and the crack length-to-cylindrical shell perimeter ( λ = a/(2 πr)) and shell length-to-diameter ( L/ D) ratios on the buckling and post-buckling behavior of cylindrical shells has been investigated. For several specimens, buckling test was performed using an INSTRON 8802 servo hydraulic machine, and the results of experimental tests were compared to numerical results. A very good correlation was observed between numerical simulation and experimental results. Finally, based on the experimental and numerical results, sensitivity of the buckling load to the shell length, crack length and orientation has also been investigated.

  6. A study on the reproducibility and spatial uniformity of N-isopropylacrylamide polymer gel dosimetry using a commercial 10X fast optical-computed tomography scanner

    NASA Astrophysics Data System (ADS)

    Chang, Y. J.; Lin, J. Q.; Hsieh, B. T.; Chen, C. H.

    2013-06-01

    This study investigated the reproducibility and spatial uniformity of N-isopropylacrylamide (NIPAM) polymer gel as well as the reproducibility of a NIPAM polymer gel dosimeter. A commercial 10X fast optical computed tomography scanner (OCTOPUS-10X, MGS Research, Inc., Madison, CT, USA) was used as the readout tool of the NIPAM polymer gel dosimeter. A cylindrical NIPAM gel phantom measuring 10 cm (diameter) by 10 cm (height) by 3 mm (thickness) was irradiated by the four-field box treatment with a field size of 3 cm × 3 cm. The dose profiles were found to be consistent at the depths of 2.0 cm to 5.0 cm for two independent gel phantom batches, and the average uncertainty was less than 2%. The gamma pass rates were calculated to be between 94% and 95% at depths of 40 mm for two independent gel phantom batches using 4% dose difference and 4 mm distance-to-agreement criterion. The NIPAM polymer gel dosimeter was highly reproducible and spatially uniform. The results highlighted the potential of the NIPAM polymer gel dosimeter in radiotherapy.

  7. Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method.

    PubMed

    Saito, Masatoshi

    2009-08-01

    Dual-energy computed tomography (DECT) has the potential for measuring electron density distribution in a human body to predict the range of particle beams for treatment planning in proton or heavy-ion radiotherapy. However, thus far, a practical dual-energy method that can be used to precisely determine electron density for treatment planning in particle radiotherapy has not been developed. In this article, another DECT technique involving a balanced filter method using a conventional x-ray tube is described. For the spectral optimization of DECT using balanced filters, the author calculates beam-hardening error and air kerma required to achieve a desired noise level in electron density and effective atomic number images of a cylindrical water phantom with 50 cm diameter. The calculation enables the selection of beam parameters such as tube voltage, balanced filter material, and its thickness. The optimized parameters were applied to cases with different phantom diameters ranging from 5 to 50 cm for the calculations. The author predicts that the optimal combination of tube voltages would be 80 and 140 kV with Tb/Hf and Bi/Mo filter pairs for the 50-cm-diameter water phantom. When a single phantom calibration at a diameter of 25 cm was employed to cover all phantom sizes, maximum absolute beam-hardening errors were 0.3% and 0.03% for electron density and effective atomic number, respectively, over a range of diameters of the water phantom. The beam-hardening errors were 1/10 or less as compared to those obtained by conventional DECT, although the dose was twice that of the conventional DECT case. From the viewpoint of beam hardening and the tube-loading efficiency, the present DECT using balanced filters would be significantly more effective in measuring the electron density than the conventional DECT. Nevertheless, further developments of low-exposure imaging technology should be necessary as well as x-ray tubes with higher outputs to apply DECT coupled with the balanced filter method for clinical use.

  8. Inertial migrations of cylindrical particles in rectangular microchannels: Variations of equilibrium positions and equivalent diameters

    NASA Astrophysics Data System (ADS)

    Su, Jinghong; Chen, Xiaodong; Hu, Guoqing

    2018-03-01

    Inertial migration has emerged as an efficient tool for manipulating both biological and engineered particles that commonly exist with non-spherical shapes in microfluidic devices. There have been numerous studies on the inertial migration of spherical particles, whereas the non-spherical particles are still largely unexplored. Here, we conduct three-dimensional direct numerical simulations to study the inertial migration of rigid cylindrical particles in rectangular microchannels with different width/height ratios under the channel Reynolds numbers (Re) varying from 50 to 400. Cylindrical particles with different length/diameter ratios and blockage ratios are also concerned. Distributions of surface force with the change of rotation angle show that surface stresses acting on the particle end near the wall are the major contributors to the particle rotation. We obtain lift forces experienced by cylindrical particles at different lateral positions on cross sections of two types of microchannels at various Re. It is found that there are always four stable equilibrium positions on the cross section of a square channel, while the stable positions are two or four in a rectangular channel, depending on Re. By comparing the equilibrium positions of cylindrical particles and spherical particles, we demonstrate that the equivalent diameter of cylindrical particles monotonously increases with Re. Our work indicates the influence of a non-spherical shape on the inertial migration and can be useful for the precise manipulation of non-spherical particles.

  9. Oscillating plasma bubble and its associated nonlinear studies in presence of low magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Megalingam, Mariammal; Sarma, Bornali; Mitra, Vramori

    Oscillating plasma bubbles have been created around a cylindrical mesh grid of 75% optical transparency in a DC plasma system with a low magnetic field. Plasma bubbles are created by developing ion density gradient around a cylindrical grid of 20 cm in diameter and 25 cm in height, inserted into the plasma. Relaxation and contraction of the plasma bubbles in the presence of external conditions, such as magnetic field and pressure, have been studied. A Langmuir probe has been used to detect the plasma floating potential fluctuations at different imposed experimental conditions. Nonlinear behavior of the system has been characterized by adoptingmore » nonlinear techniques such as Fast Fourier Transform, Phase Space Plot, and Recurrence Plot. It shows that the system creates highly nonlinear phenomena associated with the plasma bubble under the imposed experimental conditions. A theoretical and numerical model has also been developed to satisfy the observed experimental analysis. Moreover, observations are extended further to study the growth of instability associated with the plasma bubbles. The intention of the present work is to correlate the findings about plasma bubbles and their related instability with the one existing in the equatorial F-region of the ionosphere.« less

  10. Recent achievements using chemical vapor composite silicon carbide (CVC SiC)

    NASA Astrophysics Data System (ADS)

    Goodman, William A.; Tanaka, Clifford

    2009-08-01

    This annual review documents our progress towards inexpensive mass production of silicon carbide mirrors and optical structures. Results are provided for a NASA Small Business Technology Transfer (STTR) X-Ray Mirror project. Trex partnered with the University of Alabama-Huntsville Center for Advanced Optics (UAH-CAO) to develop fabrication methods for polished cylindrical and conical chemical vapor composite (CVCTM) SiC mandrels. These mandrels are envisioned as pre-forms for the replication of fused silica x-ray optics to be eventually used in the International X-Ray Observatory (IXO). CVC SiCTM offers superior high temperature stability, thermal and mechanical performance and polishability required for this precision replication process. In this program, Trex fabricated prototype mandrels with design diameters of 10.5cm, 20cm and 45cm. UAH-CAO was Trex's university partner in this effort and worked on polishing and metrology of the unusual x-ray mandrel geometries. UAH-CAO successfully developed an innovative interferometric method for measuring the CVC SiCTM x-ray mandrels based on a precision cylindrical lens system. UAH-CAO also developed finishing and polishing methods for CVC SiCTM that utilized a Zeeko IRP200 computer controlled polishing tool. The three technologies key technologies demonstrated in this program (near net shape forming of CVC SiCTM mandrels, the x-ray mandrel metrology and free-form polishing capability on CVC SiCTM) could enable cost-effective manufacture of the x-ray mandrels required for the International X-Ray Observatory (IXO).

  11. Helium-4 Experiments near T-lambda in a Low-Gravity Simulator

    NASA Technical Reports Server (NTRS)

    Liu, Yuanming; Larson, Melora; Israelsson, Ulf

    2000-01-01

    We report our studies of gravity cancellation in a liquid helium sample cell along the lambda-line using a low-gravity simulator facility. The simulator consists of a superconducting magnet capable of producing B(delta-B/delta-z) = 22squareT)/cm. We have verified experimentally that the simulator can cancel gravity to about 0.01g in a cylindrical sample volume of 0.5 cm in diameter and 0.5 cm in height. This allows us to approach more closely the superfluid transition without entering the normal-superfluid two phase region induced by gravity. We also present the measurements of T-c(Q,P): depression of the superfluid transition temperature by a heat current(Q) along the lambda-line (P). The results are consistent with the Renormalization-group theory calculation. Measurements of thermal expansion coefficient in a heat current will also be discussed. The work has been carried out by JPL, California Institute of Technology under contract to NASA.

  12. Surface Tension Driven Convection Experiment (STDCE)

    NASA Technical Reports Server (NTRS)

    Ostrach, Simon; Kamotani, Y.; Pline, A.

    1994-01-01

    Results are reported of the Surface Tension Driven Convection Experiment (STDCE) aboard the USML-1 (first United States Microgravity Laboratory) Spacelab which was launched on June 25, 1992. In the experiment 10 cSt silicone oil was placed in an open circular container which was 10 cm wide by 5 cm deep. The fluid was heated either by a cylindrical heater (1.11 cm dia.) located along the container centerline or by a CO2 laser beam to induce thermocapillary flow. The flow field was studied by flow visualization. Several thermistor probes were placed in the fluid to measure the temperature distribution. The temperature distribution along the liquid free surface was measured by an infrared imager. Tests were conducted over a range of heating powers, laser beam diameters, and free surface shapes. In conjunction with the experiments an extensive numerical modeling of the flow was conducted. In this paper some results of the velocity and temperature measurements with flat and curved free surfaces are presented and they are shown to agree well with the numerical predictions.

  13. An experimental and theoretical investigation of the liquefaction dynamics of a phase change material in a normal gravity environment

    NASA Technical Reports Server (NTRS)

    Bain, R. L.; Stermole, F. J.; Golden, J. O.

    1972-01-01

    Experimental and theoretical investigations were undertaken to determine the role of gravity-induced free convection upon the liquefaction dynamics of a cylindrical paraffin slab under normal gravity conditions. The experimental equipment consisted of a test cell, a fluid-loop heating system, and a multipoint recorder. The test chamber was annular in shape with an effective radius of 1.585 cm and a length of 5.08 cm. The heating chamber was a 1.906 cm diameter tube going through the center of the test chamber, and connected to the fluid loop heating system. All experimental runs were made with the longitudinal axis of the test cell in the vertical direction to insure that convection was not a function of the angular axis of the cell. Ten melting runs were made at various hot wall temperatures. Also, two pure conduction solidification runs were made to determine an experimental latent heat of fusion.

  14. Measurement of ion beam angular distribution at different helium gas pressures in a plasma focus device by large-area polycarbonate detectors

    NASA Astrophysics Data System (ADS)

    Sohrabi, M.; Habibi, M.; Ramezani, V.

    2017-02-01

    The paper presents an experimental study and analysis of full helium ion density angular distributions in a 4-kJ plasma focus device (PFD) at pressures of 10, 15, 25, and 30 mbar using large-area polycarbonate track detectors (PCTDs) (15-cm etchable diameter) processed by 50-Hz-HV electrochemical etching (ECE). Helium ion track distributions at different pressures, in particular, at the main axis of the PFD are presented. Maximum ion track density of 4.4 × 104 tracks/cm2 was obtained in the PCTD placed 6 cm from the anode. The ion distributions for all pressures applied are ring-shaped, which is possibly due to the hollow cylindrical copper anode used. The large-area PCTD processed by ECE proves, at the present state-of-theart, a superior method for direct observation and analysis of ion distributions at a glance with minimum efforts and time. Some observations of the ion density distributions at different pressures are reported and discussed.

  15. Application Prospects of Multilayer Film Shields for Space Research Instrumentation

    NASA Astrophysics Data System (ADS)

    Nyunt, P. W.; Vlasik, K. F.; Grachev, V. M.; Dmitrenko, V. V.; Novikov, A. S.; Petrenko, D. V.; Ulin, S. E.; Uteshev, Z. M.; Chernysheva, I. V.; Shustov, A. E.

    We have studied the magnetic properties of multilayer film cylindrical configuration shields (MFS) based on NiFe / Cu. The studied samples were prepared by electrode position. MFS were constituted by alternating layers of NiFe and Cu, deposited on an aluminum cylinder with diameter of 4 cm, length of 13 cm and 0.5 cm thickness. The thickness of each ferromagnetic layer varied from 10 to 150 μm, and the thickness of Cu layers was 5 μm. Five-samples in which the number of ferromagnetic layers varied from 3 to 45 and copper - from 2 to 44 were tested. The best shielding efficiency was achieved at the maximum number of layers and comprised about 102. Permalloy multilayer foil shield at the same total thickness has several times less efficiency in comparison with MFS. The description of a prototype of the charged particles telescope for space application is presented. Results of its testing regarding sensitivity to the constant magnetic field are described.

  16. Thrust generation experiments on microwave rocket with a beam concentrator for long distance wireless power feeding

    NASA Astrophysics Data System (ADS)

    Fukunari, Masafumi; Yamaguchi, Toshikazu; Nakamura, Yusuke; Komurasaki, Kimiya; Oda, Yasuhisa; Kajiwara, Ken; Takahashi, Koji; Sakamoto, Keishi

    2018-04-01

    Experiments using a 1 MW-class gyrotron were conducted to examine a beamed energy propulsion rocket, a microwave rocket with a beam concentrator for long-distance wireless power feeding. The incident beam is transmitted from a beam transmission mirror system. The beam transmission mirror system expands the incident beam diameter to 240 mm to extend the Rayleigh length. The beam concentrator receives the beam and guides it into a 56-mm-diameter cylindrical thruster tube. Plasma ignition and ionization front propagation in the thruster were observed through an acrylic window using a fast-framing camera. Atmospheric air was used as a propellant. Thrust generation was achieved with the beam concentrator. The maximum thrust impulse was estimated as 71 mN s/pulse from a pressure history at the thrust wall at the input energy of 638 J/pulse. The corresponding momentum coupling coefficient, Cm was inferred as 204 N/MW.

  17. Tokamak blanket design study, final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-08-01

    A cylindrical module concept was developed, analyzed, and incorporated in a tokamak blanket system that includes piping systems, vacuum boundary sealing, and support structures. The design is based on the use of state-of-the-art structural materials (20% cold-worked type 316 stainless steel), lithium as the breeding material, and pressurized helium as the coolant. The module design consists of nested concentric cylinders (with an outer diameter of 10 cm) and features direct wall cooling by helium flowing between the outer (first-wall) cylinder and the inner (lithium-containing) cylinder. Each cylinder can withstand full coolant pressure, thus enhancing reliability. Results show that stainless steelmore » is a viable material for a first wall subjected to a neutron wall loading of 4 MW/m/sup 2/ and a particle heat flux of 1 MW/m/sup 2/. Lifetime analysis shows that the first-wall design meets the goal of operating at 20-min cycles with 95% duty for 100,000 cycles. To reduce system complexity, a larger 20-cm-diam module also was analyzed for incorporation in the blanket assembly. Reliability assessment indicates that it may be possible to double the module in size from 10 to 20 cm in diameter. With a modest increase in coolant pumping power, a blanket assembly comprising 20-cm-diam modules can still achieve 100,000 operating cycles - equivalent to a 3.6-year design lifetime - with only one or two helium coolant leaks into the plasma.« less

  18. Square lattice honeycomb reactor for space power and propulsion

    NASA Astrophysics Data System (ADS)

    Gouw, Reza; Anghaie, Samim

    2000-01-01

    The most recent nuclear design study at the Innovative Nuclear Space Power and Propulsion Institute (INSPI) is the Moderated Square-Lattice Honeycomb (M-SLHC) reactor design utilizing the solid solution of ternary carbide fuels. The reactor is fueled with solid solution of 93% enriched (U,Zr,Nb)C. The square-lattice honeycomb design provides high strength and is amenable to the processing complexities of these ultrahigh temperature fuels. The optimum core configuration requires a balance between high specific impulse and thrust level performance, and maintaining the temperature and strength limits of the fuel. The M-SLHC design is based on a cylindrical core that has critical radius and length of 37 cm and 50 cm, respectively. This design utilized zirconium hydrate to act as moderator. The fuel sub-assemblies are designed as cylindrical tubes with 12 cm in diameter and 10 cm in length. Five fuel subassemblies are stacked up axially to form one complete fuel assembly. These fuel assemblies are then arranged in the circular arrangement to form two fuel regions. The first fuel region consists of six fuel assemblies, and 18 fuel assemblies for the second fuel region. A 10-cm radial beryllium reflector in addition to 10-cm top axial beryllium reflector is used to reduce neutron leakage from the system. To perform nuclear design analysis of the M-SLHC design, a series of neutron transport and diffusion codes are used. To optimize the system design, five axial regions are specified. In each axial region, temperature and fuel density are varied. The axial and radial power distributions for the system are calculated, as well as the axial and radial flux distributions. Temperature coefficients of the system are also calculated. A water submersion accident scenario is also analyzed for these systems. Results of the nuclear design analysis indicate that a compact core can be designed based on ternary uranium carbide square-lattice honeycomb fuel, which provides a relatively high thrust to weight ratio. .

  19. Highly organised and dense vertical silicon nanowire arrays grown in porous alumina template on <100> silicon wafers

    PubMed Central

    2013-01-01

    In this work, nanoimprint lithography combined with standard anodization etching is used to make perfectly organised triangular arrays of vertical cylindrical alumina nanopores onto standard <100>−oriented silicon wafers. Both the pore diameter and the period of alumina porous array are well controlled and can be tuned: the periods vary from 80 to 460 nm, and the diameters vary from 15 nm to any required diameter. These porous thin layers are then successfully used as templates for the guided epitaxial growth of organised mono-crystalline silicon nanowire arrays in a chemical vapour deposition chamber. We report the densities of silicon nanowires up to 9 × 109 cm−2 organised in highly regular arrays with excellent diameter distribution. All process steps are demonstrated on surfaces up to 2 × 2 cm2. Specific emphasis was made to select techniques compatible with microelectronic fabrication standards, adaptable to large surface samples and with a reasonable cost. Achievements made in the quality of the porous alumina array, therefore on the silicon nanowire array, widen the number of potential applications for this technology, such as optical detectors or biological sensors. PMID:23773702

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, H; Hu, Y; Hwang, Y

    Purpose: This study was to investigate size-specific dose estimates (SSDE) for routine adult abdominal CT examinations in Taiwan. Methods: A national survey was conducted in Taiwan in 2014 to investigate SSDEs for routine adult abdominal CT examinations. The hospitals involved in this study provided CT images of their typical patients. The CT image in the level of the middle liver was selected to record the corresponding tube current, slice mAs or effective mAs. The image was also used to estimate the dimensions of patient as measuring the lengths in the anterior to posterior (AP) and lateral (LAT) directions. The effectivemore » diameter was then calculated from AP and LAT, and used to look up conversion factors in the AAPM 204 report. The volume CTDI (CTDIvol) for each CT unit was measured on sites using a 32-cm cylindrical standard dose phantom and a calibrated pencil-type ionization chamber. Individual patient’s SSDEs were then calculated from the corresponding SSDE conversion factor and the CTDIvol. Results: The study cohort included 111 CT units. The ratio of turning on automatic tube current modulation (ATCM) or not is 88:23. Effective diameters are 258.7±25.1 mm (167–366 mm). 99.3% of typical patients selected by each hospital have smaller effective diameter than the 32-cm dosimetry phantom. Adult abdomenal SSDE is 17.5 ± 8.8 mGy (1.9-58 mGy). The SSDE seems to decrease as the effective diameter increases as the ATCM turns off, and independent with the effective diameter as the ATCM turns on. Conclusion: The SSDE for typical patients in Taiwan was investigated. We continue to complete this investigation in 2015 to include more valid data to establish SSDE reference level in Taiwan. This study was financially supported by the Atomic Energy Council in Taiwan.« less

  1. Cylindrical surface profile and diameter measuring tool and method

    NASA Technical Reports Server (NTRS)

    Currie, James R. (Inventor); Kissel, Ralph R. (Inventor); Smith, Earnest C. (Inventor); Oliver, Charles E. (Inventor); Redmon, John W., Sr. (Inventor); Wallace, Charles C. (Inventor); Swanson, Charles P. (Inventor)

    1987-01-01

    A tool is shown having a cross beam assembly made of beams joined by a center box structure. The assembly is adapted to be mounted by brackets to the outer end of a cylindrical case. The center box structure has a vertical shaft rotatably mounted therein and extending beneath the assembly. Secured to the vertical shaft is a radius arm which is adapted to rotate with the shaft. On the longer end of the radius arm is a measuring tip which contacts the cylindrical surface to be measured and which provides an electric signal representing the radius of the cylindrical surface from the center of rotation of the radius arm. An electric servomotor rotates the vertical shaft and an electronic resolver provides an electric signal representing the angle of rotation of the shaft. The electric signals are provided to a computer station which has software for its computer to calculate and print out the continuous circumference profile of the cylindrical surface, and give its true diameter and the deviations from the ideal circle.

  2. Pressurized water nuclear reactor system with hot leg vortex mitigator

    DOEpatents

    Lau, Louis K. S.

    1990-01-01

    A pressurized water nuclear reactor system includes a vortex mitigator in the form of a cylindrical conduit between the hot leg conduit and a first section of residual heat removal conduit, which conduit leads to a pump and a second section of residual heat removal conduit leading back to the reactor pressure vessel. The cylindrical conduit is of such a size that where the hot leg has an inner diameter D.sub.1, the first section has an inner diameter D.sub.2, and the cylindrical conduit or step nozzle has a length L and an inner diameter of D.sub.3 ; D.sub.3 /D.sub.1 is at least 0.55, D.sub.2 is at least 1.9, and L/D.sub.3 is at least 1.44, whereby cavitation of the pump by a vortex formed in the hot leg is prevented.

  3. Design, fabrication, and test of lightweight shell structure, phase 2

    NASA Technical Reports Server (NTRS)

    1974-01-01

    A cylindrical shell skirt structure 4.57 m (180 in.) in diameter and 3.66 m (144 in.) high was subjected to a design and analysis study using a wide variety of structural materials and concepts. The design loading of 1225.8 N/cm (700 lb/in.) axial compression and 245.2 N/cm (140 lb/in.) torsion is representative of that expected on a typical space tug skirt section. Structural concepts evaluated included honeycomb sandwich, truss, isogrid, and skin/stringer/frame. The materials considered included a wide variety of structural metals as well as glass, graphite, and boron-reinforced composites. The most unique characteristic of the candidate designs is that they involve the use of very thin-gage material. Fabrication and structural test of small panels and components representative of many of the candidate designs served to demonstrate proposed fabrication techniques and to verify design and analysis methods.

  4. Target with a frozen nuclear polarization for experiments at low energies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borisov, N.S.; Matafonov, V.N.; Neganov, A.B.

    1995-09-01

    The short history of the development of frozen spin polarized targets at the Laboratory of Nuclear Problems JINR is given. The latest development is the target with a frozen spin polarization of protons in 1,2- propanediol with a paramagnetic Cr{sup {ital V}} impurity, intended for polarization parameter studies in np-scattering at approximately 15 MeV neutron energy. The target of cylindrical shape of 2 cm diameter and 6 cm long with an initial polarization of 95{plus_minus}3{percent} obtainable by the dynamic polarization technique is placed at a temperature about 20 mK in a magnetic field of 0.37 T generated by a magneticmore » system, which provides a large aperture for scattered particles. The relaxation time for the spin polarization is about 1000 hours. {copyright} {ital 1995 American Institute of Physics.}« less

  5. Testing Moderating Detection Systems with {sup 252}Cf-Based Reference Neutron Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertel, Nolan E.; Sweezy, Jeremy; Sauber, Jeremiah S.

    Calibration measurements were carried out on a probe designed to measure ambient dose equivalent in accordance with ICRP Pub 60 recommendations. It consists of a cylindrical {sup 3}He proportional counter surrounded by a 25-cm-diameter spherical polyethylene moderator. Its neutron response is optimized for dose rate measurements of neutrons between thermal energies and 20 MeV. The instrument was used to measure the dose rate in four separate neutron fields: unmoderated {sup 252}Cf, D{sub 2}O-moderated {sup 252}Cf, polyethylene-moderated {sup 252}Cf, and WEP neutron howitzer with {sup 252}Cf at its center. Dose equivalent measurements were performed at source-detector centerline distances from 50 tomore » 200 cm. The ratio of air-scatter- and room-return-corrected ambient dose equivalent rates to ambient dose equivalent rates calculated with the code MCNP are tabulated.« less

  6. Influence of detector pixel size, TOF resolution and DOI on image quality in MR-compatible whole-body PET.

    PubMed

    Thoen, Hendrik; Keereman, Vincent; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2013-09-21

    The optimization of a whole-body PET system remains a challenging task, as the imaging performance is influenced by a complex interaction of different design parameters. However, it is not always clear which parameters have the largest impact on image quality and are most eligible for optimization. To determine this, we need to be able to assess their influence on image quality. We performed Monte-Carlo simulations of a whole-body PET scanner to predict the influence on image quality of three detector parameters: the TOF resolution, the transverse pixel size and depth-of-interaction (DOI)-correction. The inner diameter of the PET scanner was 65 cm, small enough to allow physical integration into a simultaneous PET-MR system. Point sources were used to evaluate the influence of transverse pixel size and DOI-correction on spatial resolution as function of radial distance. To evaluate the influence on contrast recovery and pixel noise a cylindrical phantom of 35 cm diameter was used, representing a large patient. The phantom contained multiple hot lesions with 5 mm diameter. These lesions were placed at radial distances of 50, 100 and 150 mm from the center of the field-of-view, to be able to study the effects at different radial positions. The non-prewhitening (NPW) observer was used for objective analysis of the detectability of the hot lesions in the cylindrical phantom. Based on this analysis the NPW-SNR was used to quantify the relative improvements in image quality due to changes of the variable detector parameters. The image quality of a whole-body PET scanner can be improved significantly by reducing the transverse pixel size from 4 to 2.6 mm and improving the TOF resolution from 600 to 400 ps and further from 400 to 200 ps. Compared to pixel size, the TOF resolution has the larger potential to increase image quality for the simulated phantom. The introduction of two layer DOI-correction only leads to a modest improvement for the spheres at radial distance of 150 mm from the center of the transaxial FOV.

  7. Cylindrical acoustic levitator/concentrator

    DOEpatents

    Kaduchak, Gregory; Sinha, Dipen N.

    2002-01-01

    A low-power, inexpensive acoustic apparatus for levitation and/or concentration of aerosols and small liquid/solid samples having particulates up to several millimeters in diameter in air or other fluids is described. It is constructed from a commercially available, hollow cylindrical piezoelectric crystal which has been modified to tune the resonance frequency of the breathing mode resonance of the crystal to that of the interior cavity of the cylinder. When the resonance frequency of the interior cylindrical cavity is matched to the breathing mode resonance of the cylindrical piezoelectric transducer, the acoustic efficiency for establishing a standing wave pattern in the cavity is high. The cylinder does not require accurate alignment of a resonant cavity. Water droplets having diameters greater than 1 mm have been levitated against the force of gravity using; less than 1 W of input electrical power. Concentration of aerosol particles in air is also demonstrated.

  8. Development of large volume double ring penning plasma discharge source for efficient light emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prakash, Ram; Vyas, Gheesa Lal; Jain, Jalaj

    In this paper, the development of large volume double ring Penning plasma discharge source for efficient light emissions is reported. The developed Penning discharge source consists of two cylindrical end cathodes of stainless steel having radius 6 cm and a gap 5.5 cm between them, which are fitted in the top and bottom flanges of the vacuum chamber. Two stainless steel anode rings with thickness 0.4 cm and inner diameters 6.45 cm having separation 2 cm are kept at the discharge centre. Neodymium (Nd{sub 2}Fe{sub 14}B) permanent magnets are physically inserted behind the cathodes for producing nearly uniform magnetic fieldmore » of {approx}0.1 T at the center. Experiments and simulations have been performed for single and double anode ring configurations using helium gas discharge, which infer that double ring configuration gives better light emissions in the large volume Penning plasma discharge arrangement. The optical emission spectroscopy measurements are used to complement the observations. The spectral line-ratio technique is utilized to determine the electron plasma density. The estimated electron plasma density in double ring plasma configuration is {approx}2 Multiplication-Sign 10{sup 11} cm{sup -3}, which is around one order of magnitude larger than that of single ring arrangement.« less

  9. Development of large volume double ring penning plasma discharge source for efficient light emissions.

    PubMed

    Prakash, Ram; Vyas, Gheesa Lal; Jain, Jalaj; Prajapati, Jitendra; Pal, Udit Narayan; Chowdhuri, Malay Bikas; Manchanda, Ranjana

    2012-12-01

    In this paper, the development of large volume double ring Penning plasma discharge source for efficient light emissions is reported. The developed Penning discharge source consists of two cylindrical end cathodes of stainless steel having radius 6 cm and a gap 5.5 cm between them, which are fitted in the top and bottom flanges of the vacuum chamber. Two stainless steel anode rings with thickness 0.4 cm and inner diameters 6.45 cm having separation 2 cm are kept at the discharge centre. Neodymium (Nd(2)Fe(14)B) permanent magnets are physically inserted behind the cathodes for producing nearly uniform magnetic field of ~0.1 T at the center. Experiments and simulations have been performed for single and double anode ring configurations using helium gas discharge, which infer that double ring configuration gives better light emissions in the large volume Penning plasma discharge arrangement. The optical emission spectroscopy measurements are used to complement the observations. The spectral line-ratio technique is utilized to determine the electron plasma density. The estimated electron plasma density in double ring plasma configuration is ~2 × 10(11) cm(-3), which is around one order of magnitude larger than that of single ring arrangement.

  10. Ionization assisted self-guiding of femtosecond laser pulses

    NASA Astrophysics Data System (ADS)

    Morozov, A.; Goltsov, A.; Chen, Q.; Scully, M.; Suckewer, S.

    2018-05-01

    We propose a new mechanism for the self-guiding of ultra-intense sub-picosecond laser pulses in gaseous media. It can be realized via optical field ionization by a laser pulse as it propagates inside an expanding cylindrical shock wave launched into ambient gas by a decayed plasma filament. In experiments, the filament was created in a hydrogen jet by a low energy femtosecond laser pre-pulse line focused with axicon lens. We demonstrated ionization-assisted guiding in structures with diameter as small as 14 μm and up to 3.5 mm long. The intensity reached 5 × 1017 W/cm2 in a single mode propagating for more than 100 Rayleigh lengths.

  11. The influence of the blood vessel diameter on the full scattering profile from cylindrical tissues: experimental evidence for the shielding effect.

    PubMed

    Feder, Idit; Duadi, Hamootal; Dreifuss, Tamar; Fixler, Dror

    2016-10-01

    Optical methods for detecting physiological state based on light-tissue interaction are noninvasive, inexpensive, simplistic, and thus very useful. The blood vessels in human tissue are the main cause of light absorbing and scattering. Therefore, the effect of blood vessels on light-tissue interactions is essential for optically detecting physiological tissue state, such as oxygen saturation, blood perfusion and blood pressure. We have previously suggested a new theoretical and experimental method for measuring the full scattering profile, which is the angular distribution of light intensity, of cylindrical tissues. In this work we will present experimental measurements of the full scattering profile of heterogenic cylindrical phantoms that include blood vessels. We show, for the first time that the vessel diameter influences the full scattering profile, and found higher reflection intensity for larger vessel diameters accordance to the shielding effect. For an increase of 60% in the vessel diameter the light intensity in the full scattering profile above 90° is between 9% to 40% higher, depending on the angle. By these results we claim that during respiration, when the blood-vessel diameter changes, it is essential to consider the blood-vessel diameter distribution in order to determine the optical path in tissues. A CT scan of the measured silicon-based phantoms. The phantoms contain the same blood volume in different blood-vessel diameters. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Stress Analysis of Bolted, Segmented Cylindrical Shells Exhibiting Flange Mating-Surface Waviness

    NASA Technical Reports Server (NTRS)

    Knight, Norman F., Jr.; Phillips, Dawn R.; Raju, Ivatury S.

    2009-01-01

    Bolted, segmented cylindrical shells are a common structural component in many engineering systems especially for aerospace launch vehicles. Segmented shells are often needed due to limitations of manufacturing capabilities or transportation issues related to very long, large-diameter cylindrical shells. These cylindrical shells typically have a flange or ring welded to opposite ends so that shell segments can be mated together and bolted to form a larger structural system. As the diameter of these shells increases, maintaining strict fabrication tolerances for the flanges to be flat and parallel on a welded structure is an extreme challenge. Local fit-up stresses develop in the structure due to flange mating-surface mismatch (flange waviness). These local stresses need to be considered when predicting a critical initial flaw size. Flange waviness is one contributor to the fit-up stress state. The present paper describes the modeling and analysis effort to simulate fit-up stresses due to flange waviness in a typical bolted, segmented cylindrical shell. Results from parametric studies are presented for various flange mating-surface waviness distributions and amplitudes.

  13. Preparation and magnetic properties of cylindrical NiFe films and antidot arrays.

    PubMed

    Sanz, R; Navas, D; Vazquez, M; Hernández-Vélez, M; Ross, C A

    2010-10-01

    Continuous NiFe (Permalloy) cylindrical films and arrays of cylindrical NiFe antidots 7 nm thick have been prepared by sputtering onto cylindrical aluminum wires and onto wires anodized to form a porous anodic alumina layer. The antidots are arranged in a close-packed pattern determined by the hexagonal pore arrangement in the porous alumina, with period 103 nm and diameter 42 nm. Hysteresis loops were measured at different angles with respect to the cylinder axis and indicate an easy plane normal to the radius of the wire. The antidots enhance the coercivity compared to the continuous cylindrical film.

  14. Multi-Shock Shield Performance at 15 MJ for Catalogued Debris

    NASA Technical Reports Server (NTRS)

    Miller, J. E.; Davis, B. A.; Christiansen, E. L.; Lear, D. M.

    2015-01-01

    While orbital debris of ten centimeters or more are tracked and catalogued, the difficulty of finding and accurately accounting for forces acting on the objects near the ten centimeter threshold results in both uncertainty of their presence and location. These challenges result in difficult decisions for operators balancing potential costly operational approaches with system loss risk. In this paper, the assessment of the feasibility of protecting a spacecraft from this catalogued debris is described using numerical simulations and a test of a multi-shock shield system against a cylindrical projectile impacting normal to the surface with approximately 15 MJ of kinetic energy. The hypervelocity impact test has been conducted at the Arnold Engineering Development Complex (AEDC) with a 598 g projectile at 6.905 km/s on a NASA supplied multi-shock shield. The projectile used is a hollow aluminum and nylon cylinder with an outside diameter of 8.6 cm and length of 10.3 cm. Figure 1 illustrates the multi-shock shield test article, which consisted of five separate bumpers, four of which are fiberglass fabric and one of steel mesh, and two rear walls, each consisting of Kevlar fabric. The overall length of the test article was 2.65 m. The test article was a 5X scaled-up version of a smaller multi-shock shield previously tested using a 1.4 cm diameter aluminum projectile for an inflatable module project. The distances represented by S1 and S1/2 in the figure are 61 cm and 30.5 cm, respectively. Prior to the impact test, hydrodynamic simulations indicated that some enhancement to the standard multi-shock system is needed to address the effects of the cylindrical shape of the projectile. Based on the simulations, a steel mesh bumper has been added to the shield configuration to enhance the fragmentation of the projectile. The AEDC test occurred as planned, and the modified NASA multi-shock shield successfully stopped 598 g projectile using 85.6 kg/m(exp 2). The fifth bumper layer remained in tact, although it was torn free from its support structure and thrown into the first rear wall. The outer Kevlar layer of the first rear wall tore likely from the impact of the fifth bumper's support structure, but the back of the rear wall was intact. No damage occurred to the second rear wall, or to the witness plate behind the target.

  15. Processing and Testing of Thermoplastic Composite Cylindrical Shells Fabricated by Automated Fiber Placement

    NASA Technical Reports Server (NTRS)

    Hulcher, Anthony Bruce; McGowan, David M.; Grimsley, Brian W.; Johnston, Norman J.; Gordon, Gail H. (Technical Monitor)

    2001-01-01

    Two 61-cm-diameter eight-ply quasi-isotropic IM7/PEEK cylindrical shells were fabricated by automated fiber placement the NASA Langley Research Center using only infrared radiant heat to preheat the substrate and incoming composite uni-tape. The shells were characterized by ultrasonic c-scans for overall consolidation quality, and by optical microscopy and acid digestion for void content. Compression tests were also performed. Although the material used in the study was of generally poor quality due to numerous splits and dry fiber regions, the process was able to achieve a net reduction in void content in the as-placed component. Microscopy of the composite shells revealed well-consolidated, void-free interfaces. The two cylinders were then tested in uni-axial compression in a 1334 kN-capacity hydraulic test machine until buckling occurred. A geometrically nonlinear finite element analysis was conducted, and the differences between the predicted and measured values were 18.0 and 25.8%, respectively. Inclusion of measured imperfections of the cylinder into the analysis is expected to reduce these differences.

  16. Triggering regime of oil-filled trigatron dischargers

    NASA Astrophysics Data System (ADS)

    Kapishnikov, N. K.; Muratov, V. M.

    1986-11-01

    A comparative analysis made in [1, 2] of different types of regulable high-voltage dischargers with liquid insulation showed that trigatrons are currently the most promising for use in high-voltage pulse-operated devices due to their simplicity and reliability. Two basic mechanisms of discharge initiation can be realized in trigatrons — initiation by intensification of the field in the region of the control electrode [2, 3], and triggering by a spark in the ignition gap [4, 5]. The first type of trigatron has been studied sufficiently only for short voltage periods [3, 6, 7], so it is used mainly in switching the pulse-shaping lines of powerful nanosecond pulse generators with “rapid” (0.5 1.5 μsec) charging [8, 9]. Almost no use is now made of the second type of trigatron switch in high-voltage pulse technology due to its unsatisfactory time characteristics. Here we report results of a study of the time characteristics of both types of oil-filled trigatrons operating in a regime whereby they form the leading edge of rectangular voltage pulses with amplitudes up to 800 kV and durations of 1 100 μsec. The goal is to find the optimum conditions for triggering of trigatron dischargers with liquid insulation in the region of microsecond voltage discharges. Experiments were conducted on the unit in [10]. The test discharger was placed in a cylindrical chamber 45 cm in diameter and 27 cm in length. The high-voltage electrode of the discharger was in the form of a cylinder 20 cm in diameter positioned coaxially inside the chamber. The 10-mm-diameter ground electrode was positioned radially in a branch pipe 8 cm long. The control electrode was placed in a 2-cm-diameter hole in the center of the ground electrode. The chamber with the test discharge was filled with transformer oil with a breakdown voltage of about 50 kV. The oil was not replaced or cleaned during the experiment. We did not find that contamination of the oil by discharge products had any effect on the time characteristics of either type of discharger. The results were analyzed by the least squares method, with 50 measurements to a point (it was found that time lag of the discharger triggering conforms approximately to a normal distribution law for both types of discharger).

  17. Disinfection of Mycobacterium avium subspecies hominissuis in drinking tap water using ultraviolet germicidal irradiation.

    PubMed

    Schiavano, Giuditta Fiorella; De Santi, Mauro; Sisti, Maurizio; Amagliani, Giulia; Brandi, Giorgio

    2017-09-13

    Nontuberculous mycobacteria are resistant to conventional water treatments, and are opportunistic human pathogen, particularly in hospitalized patients. The aim of this investigation was to assess the effectiveness of an ultraviolet UV-C lamp treatment against Mycobacterium avium subspecies hominissuis in drinking tap water. Ultraviolet treatments (0-192 mJ/cm 2 ) were performed using UV lamp immerged onto cylindrical glass tubes containing artificially contaminated water. The results showed that susceptibility to UV varied considerably according to the strains and the diameter of the tube. With a dose of 32 mJ/cm 2 , a significant inactivation (p < .05) of 3 log (99.9%) or more was obtained in only 5 of the 14 strains. To obtain a complete inactivation of all strains an irradiation of 192 mJ/cm 2 was needed, a dose that is much higher than the limits recommended by the international standards for UV disinfection of drinking water. In conclusion, it may be difficult to standardize a UV dose for the elimination of waterborne mycobacteria.

  18. Measurement of ion beam angular distribution at different helium gas pressures in a plasma focus device by large-area polycarbonate detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sohrabi, M.; Habibi, M., E-mail: mortezahabibi@gmail.com; Ramezani, V.

    2017-02-15

    The paper presents an experimental study and analysis of full helium ion density angular distributions in a 4-kJ plasma focus device (PFD) at pressures of 10, 15, 25, and 30 mbar using large-area polycarbonate track detectors (PCTDs) (15-cm etchable diameter) processed by 50-Hz-HV electrochemical etching (ECE). Helium ion track distributions at different pressures, in particular, at the main axis of the PFD are presented. Maximum ion track density of ~4.4 × 10{sup 4} tracks/cm{sup 2} was obtained in the PCTD placed 6 cm from the anode. The ion distributions for all pressures applied are ring-shaped, which is possibly due tomore » the hollow cylindrical copper anode used. The large-area PCTD processed by ECE proves, at the present state-of-theart, a superior method for direct observation and analysis of ion distributions at a glance with minimum efforts and time. Some observations of the ion density distributions at different pressures are reported and discussed.« less

  19. Effect of holed reflector on acoustic radiation force in noncontact ultrasonic dispensing of small droplets

    NASA Astrophysics Data System (ADS)

    Tanaka, Hiroki; Wada, Yuji; Mizuno, Yosuke; Nakamura, Kentaro

    2016-06-01

    We investigated the fundamental aspects of droplet dispensing, which is an important procedure in the noncontact ultrasonic manipulation of droplets in air. A holed reflector was used to dispense a droplet from a 27.4 kHz standing-wave acoustic field to a well. First, the relationship between the hole diameter of the reflector and the acoustic radiation force acting on a levitated droplet was clarified by calculating the acoustic impedance of the point just above the hole. When the hole diameter was half of (or equal to) the acoustic wavelength λ, the acoustic radiation force was ∼80% (or 50%) of that without a hole. The maximal diameters of droplets levitated above the holes through flat and half-cylindrical reflectors were then experimentally investigated. For instance, with the half-cylindrical reflector, the maximal diameter was 5.0 mm for a hole diameter of 6.0 mm, and droplets were levitatable up to a hole diameter of 12 mm (∼λ).

  20. Capture-gated Spectroscopic Measurements of Monoenergetic Neutrons with a Composite Scintillation Detector

    NASA Astrophysics Data System (ADS)

    Nattress, Jason; Mayer, M.; Foster, A.; Meddeb, A. Barhoumi; Trivelpiece, C.; Ounaies, Z.; Jovanovic, I.

    2016-04-01

    We report on the measurements of monoenergetic neutrons from DD and DT fusion reactions by use of the capture gating method in a heterogeneous plastic-glass composite scintillation detector. The cylindrical detector is 5.08 cm in diameter and 5.05 cm in height and was fabricated using 1-mm diameter Li-doped glass rods (GS20) and scintillating polyvinyl toluene (EJ-290). Different scintillation decay constants are used to identify energy depositions in two materials constituting the composite scintillator. Geant4 simulations of the neutron thermalization and capture process were conducted, finding a mean capture time of approximately 2.6 μs for both DD and DT neutrons. A capture gating time acceptance window based on simulation results was used to identify the neutron thermalization pulses. The total scintillation light yield produced in neutron thermalization was measured and found to show consistency on event-by-event basis despite the variety of neutron thermalization histories prior to capture. The ratio of light yields from thermalization of 14.1 MeV and 2.45 MeV neutrons in the EJ-290 scintillator was determined to be 14.6, and the light output from 2.45 MeV neutrons was also correlated to its electron equivalent, obtaining a value of 0.58±0.05 MeVee.

  1. Bubble Size Distribution in a Vibrating Bubble Column

    NASA Astrophysics Data System (ADS)

    Mohagheghian, Shahrouz; Wilson, Trevor; Valenzuela, Bret; Hinds, Tyler; Moseni, Kevin; Elbing, Brian

    2016-11-01

    While vibrating bubble columns have increased the mass transfer between phases, a universal scaling law remains elusive. Attempts to predict mass transfer rates in large industrial scale applications by extrapolating laboratory scale models have failed. In a stationary bubble column, mass transfer is a function of phase interfacial area (PIA), while PIA is determined based on the bubble size distribution (BSD). On the other hand, BSD is influenced by the injection characteristics and liquid phase dynamics and properties. Vibration modifies the BSD by impacting the gas and gas-liquid dynamics. This work uses a vibrating cylindrical bubble column to investigate the effect of gas injection and vibration characteristics on the BSD. The bubble column has a 10 cm diameter and was filled with water to a depth of 90 cm above the tip of the orifice tube injector. BSD was measured using high-speed imaging to determine the projected area of individual bubbles, which the nominal bubble diameter was then calculated assuming spherical bubbles. The BSD dependence on the distance from the injector, injector design (1.6 and 0.8 mm ID), air flow rates (0.5 to 5 lit/min), and vibration conditions (stationary and vibration conditions varying amplitude and frequency) will be presented. In addition to mean data, higher order statistics will also be provided.

  2. Radial force distribution changes associated with tangential force production in cylindrical grasping, and the importance of anatomical registration.

    PubMed

    Pataky, Todd C; Slota, Gregory P; Latash, Mark L; Zatsiorsky, Vladimir M

    2012-01-10

    Radial force (F(r)) distributions describe grip force coordination about a cylindrical object. Recent studies have employed only explicit F(r) tasks, and have not normalized for anatomical variance when considering F(r) distributions. The goals of the present study were (i) to explore F(r) during tangential force production tasks, and (ii) to examine the extent to which anatomical registration (i.e. spatial normalization of anatomically analogous structures) could improve signal detectability in F(r) data. Twelve subjects grasped a vertically oriented cylindrical handle (diameter=6 cm) and matched target upward tangential forces of 10, 20, and 30 N. F(r) data were measured using a flexible pressure mat with an angular resolution of 4.8°, and were registered using piecewise-linear interpolation between five manually identified points-of-interest. Results indicate that F(r) was primarily limited to three contact regions: the distal thumb, the distal fingers, and the fingers' metatacarpal heads, and that, while increases in tangential force caused significant increases in F(r) for these regions, they did not significantly affect the F(r) distribution across the hand. Registration was found to substantially reduce between-subject variability, as indicated by both accentuated F(r) trends, and amplification of the test statistic. These results imply that, while subjects focus F(r) primarily on three anatomical regions during cylindrical grasp, inter-subject anatomical differences introduce a variability that, if not corrected for via registration, may compromise one's ability to draw anatomically relevant conclusions from grasping force data. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Collisional disruption of porous weak sintered targets at low impact velocity

    NASA Astrophysics Data System (ADS)

    Setoh, M.; Nakamura, A. M.; Hirata, N.; Hiraoka, K.; Arakawa, M.

    Porous structure is common in asteroids and satellites of outer planets In order to study the relation between structure of the small bodies and their thermal and collisional evolution we prepared porous sintered targets measured the compressive strength and determined their impact strength Previous studies showed using sintered glass beads Love et al 1993 the targets with higher compressive strength have higher impact strength and the targets with higher porosity have higher impact strength However in these experiments the porosity of the targets were changed according to the compressive strength Therefore we fixed the porosity while the compressive strength was varied Our experiments were performed with low impact velocity condition because low impact velocities are common among icy bodies far from the Earth We sintered soda lime glass beads of 50 micron diameter and 2 5g cm -3 nominal density at various temperatures and durations to produce targets with similar porosity sim 40 and different compressive strength 0 2 sim 7 8MPa We performed impact disruption experiments using a low velocity light-gas gun at Kobe University sim 100m s We used cylindrical polycarbonate projectiles 1 5 cm in height and 1 0 cm in diameter We determined the specific energy J kg of projectile kinetic energy per kilo gram initial target mass for the condition that the largest fragment mass being the half of the initial target mass is the threshold energy for collisional disruption Q Fujiwara et al 1989 Holsapple et al

  4. Size-dependent scanning parameters (kVp and mAs) for photon-counting spectral CT system in pediatric imaging: simulation study

    NASA Astrophysics Data System (ADS)

    Chen, Han; Danielsson, Mats; Xu, Cheng

    2016-06-01

    We are developing a photon-counting spectral CT detector with a small pixel size of 0.4× 0.5 mm2, offering a potential advantage for better visualization of small structures in pediatric patients. The purpose of this study is to determine the patient size dependent scanning parameters (kVp and mAs) for pediatric CT in two imaging cases: adipose imaging and iodinated blood imaging. Cylindrical soft-tissue phantoms of diameters between 10-25 cm were used to mimic patients of different ages from 0 to 15 y. For adipose imaging, a 5 mm diameter adipose sphere was assumed as an imaging target, while in the case of iodinated imaging, an iodinated blood sphere of 1 mm in diameter was assumed. By applying the geometry of a commercial CT scanner (GE Lightspeed VCT), simulations were carried out to calculate the detectability index, {{d}\\prime 2} , with tube potentials varying from 40 to 140 kVp. The optimal kVp for each phantom in each imaging case was determined such that the dose-normalized detectability index, {{d}\\prime 2}/ dose, is maximized. With the assumption that the detectability index in pediatric imaging is required the same as in typical adult imaging, the value of mAs at optimal kVp for each phantom was selected to achieve a reference detectability index that was obtained by scanning an adult phantom (30 cm in diameter) in a typical adult CT procedure (120 kVp and 200 mAs) using a modeled energy-integrating system. For adipose imaging, the optimal kVps are 50, 60, 80, and 120 kVp, respectively, for phantoms of 10, 15, 20, and 25 cm in diameter. The corresponding mAs values required to achieve the reference detectability index are only 9%, 23%, 24%, and 54% of the mAs that is used for adult patients at 120 kVp, for 10, 15, 20, and 25 cm diameter phantoms, respectively. In the case of iodinated imaging, a tube potential of 60 kVp was found optimal for all phantoms investigated, and the mAs values required to achieve the reference detectability index are 2%, 9%, 37%, and 109% of the adult mAs. The results also indicate that with the use of respective optimal kVps, the photon-counting spectral system offers up to 30% higher {{d}\\prime 2}/ dose than the modeled energy-integrating system for adipose imaging, and 70% for iodinated imaging.

  5. Monte Carlo modelling of large scale NORM sources using MCNP.

    PubMed

    Wallace, J D

    2013-12-01

    The representative Monte Carlo modelling of large scale planar sources (for comparison to external environmental radiation fields) is undertaken using substantial diameter and thin profile planar cylindrical sources. The relative impact of source extent, soil thickness and sky-shine are investigated to guide decisions relating to representative geometries. In addition, the impact of source to detector distance on the nature of the detector response, for a range of source sizes, has been investigated. These investigations, using an MCNP based model, indicate a soil cylinder of greater than 20 m diameter and of no less than 50 cm depth/height, combined with a 20 m deep sky section above the soil cylinder, are needed to representatively model the semi-infinite plane of uniformly distributed NORM sources. Initial investigation of the effect of detector placement indicate that smaller source sizes may be used to achieve a representative response at shorter source to detector distances. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  6. Performance modeling of a wearable brain PET (BET) camera

    NASA Astrophysics Data System (ADS)

    Schmidtlein, C. R.; Turner, J. N.; Thompson, M. O.; Mandal, K. C.; Häggström, I.; Zhang, J.; Humm, J. L.; Feiglin, D. H.; Krol, A.

    2016-03-01

    Purpose: To explore, by means of analytical and Monte Carlo modeling, performance of a novel lightweight and low-cost wearable helmet-shaped Brain PET (BET) camera based on thin-film digital Geiger Avalanche Photo Diode (dGAPD) with LSO and LaBr3 scintillators for imaging in vivo human brain processes for freely moving and acting subjects responding to various stimuli in any environment. Methods: We performed analytical and Monte Carlo modeling PET performance of a spherical cap BET device and cylindrical brain PET (CYL) device, both with 25 cm diameter and the same total mass of LSO scintillator. Total mass of LSO in both the BET and CYL systems is about 32 kg for a 25 mm thick scintillator, and 13 kg for 10 mm thick scintillator (assuming an LSO density of 7.3 g/ml). We also investigated a similar system using an LaBr3 scintillator corresponding to 22 kg and 9 kg for the 25 mm and 10 mm thick systems (assuming an LaBr3 density of 5.08 g/ml). In addition, we considered a clinical whole body (WB) LSO PET/CT scanner with 82 cm ring diameter and 15.8 cm axial length to represent a reference system. BET consisted of distributed Autonomous Detector Arrays (ADAs) integrated into Intelligent Autonomous Detector Blocks (IADBs). The ADA comprised of an array of small LYSO scintillator volumes (voxels with base a×a: 1.0 <= a <= 2.0 mm and length c: 3.0 <= c <= 6.0 mm) with 5-65 μm thick reflective layers on its five sides and sixth side optically coupled to the matching array of dGAPDs and processing electronics with total thickness of 50 μm. Simulated energy resolution was 10.8% and 3.3% for LSO and LaBr3 respectively and the coincidence window was set at 2 ns. The brain was simulated as a sphere of uniform F-18 activity with diameter of 10 cm embedded in a center of water sphere with diameter of 10 cm. Results: Analytical and Monte Carlo models showed similar results for lower energy window values (458 keV versus 445 keV for LSO, and 492 keV versus 485 keV for LaBr3), and for the relative performance of system sensitivity. Monte Carlo results further showed that the BET geometry had >50% better noise equivalent count (NEC) performance relative to the CYL geometry, and >1100% better performance than a WB geometry for 25 mm thick LSO and LaBr3. For 10 mm thick LaBr3 equivalent mass systems LSO (7 mm thick) performed ~40% higher NEC than LaBr3. Analytic and Monte Carlo simulations also showed that 1×1×3 mm scintillator crystals can achieve ~1.2 mm FWHM spatial resolution. Conclusions: This study shows that a spherical cap brain PET system can provide improved NEC while preserving spatial resolution when compared to an equivalent dedicated cylindrical PET brain camera and shows greatly improved PET performance relative to a conventional whole body PET/CT. In addition, our simulations show that LSO will generally outperform LaBr3 for NEC unless the timing resolution for LaBr3 is considerably smaller than presently used for LSO, i.e. well below 300 ps.

  7. Estimation of Flow Channel Parameters for Flowing Gas Mixed with Air in Atmospheric-pressure Plasma Jets

    NASA Astrophysics Data System (ADS)

    Yambe, Kiyoyuki; Saito, Hidetoshi

    2017-12-01

    When the working gas of an atmospheric-pressure non-equilibrium (cold) plasma flows into free space, the diameter of the resulting flow channel changes continuously. The shape of the channel is observed through the light emitted by the working gas of the atmospheric-pressure plasma. When the plasma jet forms a conical shape, the diameter of the cylindrical shape, which approximates the conical shape, defines the diameter of the flow channel. When the working gas flows into the atmosphere from the inside of a quartz tube, the gas mixes with air. The molar ratio of the working gas and air is estimated from the corresponding volume ratio through the relationship between the diameter of the cylindrical plasma channel and the inner diameter of the quartz tube. The Reynolds number is calculated from the kinematic viscosity of the mixed gas and the molar ratio. The gas flow rates for the upper limit of laminar flow and the lower limit of turbulent flow are determined by the corresponding Reynolds numbers estimated from the molar ratio. It is confirmed that the plasma jet length and the internal plasma length associated with strong light emission increase with the increasing gas flow rate until the rate for the upper limit of laminar flow and the lower limit of turbulent flow, respectively. Thus, we are able to explain the increasing trend in the plasma lengths with the diameter of the flow channel and the molar ratio by using the cylindrical approximation.

  8. Alining Large Cylinders for Welding

    NASA Technical Reports Server (NTRS)

    Ehl, J. H.

    1985-01-01

    Special tooling alines and holds internally-stiffened large-diameter cylindrical parts for welding. Alinement brackets attached to strengthening fins on insides of cylindrical tank sections. Jackscrews on brackets raised or lowered to eliminate mismatches between adjacent sections. Tooling substantially reduces costs while allowing more precise control and improved quality.

  9. Cylindrical surface profile and diameter measuring tool and method

    NASA Technical Reports Server (NTRS)

    Currie, James R. (Inventor); Kissel, Ralph R. (Inventor); Oliver, Charles E. (Inventor); Smith, Earnest C. (Inventor); Redmon, John W. (Inventor); Wallace, Charles C. (Inventor); Swanson, Charles P. (Inventor)

    1989-01-01

    A tool is shown having a cross beam assembly (15) made of beams (18, 19, 20, 21) joined by a center box structure (23). The assembly (15) is adapted to be mounted by brackets (16) to the outer end of a cylindrical case (11). The center box structure (23) has a vertical shaft (25) rotatably mounted therein and extending beneath the assembly (15). Secured to the vertical shaft (25) is a radius arm (28) which is adapted to rotate with shaft (25). On the longer end of the radius arm (28) is a measuring tip (30) which contacts the cylindrical surface to be measured and which provides an electric signal representing the radius of the cylindrical surface from the center of rotation of the radius arm (28). An electric servomotor (49) rotates the vertical shaft (25) and an electronic resolver (61) provides an electric signal representing the angle of rotation of the shaft (25). The electric signals are provided to a computer station (73) which has software for its computer to calculate and print out the continuous circumference profile of the cylindrical surface, and give its true diameter and the deviations from the ideal circle.

  10. Low Gravity venting of Refrigerant 11

    NASA Technical Reports Server (NTRS)

    Labus, T. L.; Aydelott, J. C.; Lacovic, R. F.

    1972-01-01

    An experimental investigation was conducted in a five-second zero gravity facility to examine the effects of venting initially saturated Refrigerant 11 from a cylindrical container (15-cm diameter) under reduced gravitational conditions. The system Bond numbers studied were 0 (weightlessness), 9 and 63; the liquid exhibited a nearly zero-degree contact angle on the container surface. During the venting process, both liquid-vapor interface and liquid bulk vaporization occurred. The temperature of the liquid in the immediate vicinity of the liquid-vapor interface was found to decrease during venting, while the liquid bulk temperature remained constant. Qualitative observations of the effects of system acceleration, vent rate, and vapor volume presented. Quantitative information concerning the ullage pressure decay during low gravity venting is also included.

  11. Experimental Verification of Material Flammability in Space

    NASA Technical Reports Server (NTRS)

    Ivanov, A. V.; Balashov, Y. V.; Andreeva, T. V.; Melikhov, A. S.

    1999-01-01

    The flammability in microgravity of three US-furnished materials, Delrin, polymethylmethacrylate (PMMA), and high-density polyethylene, was determined using a Russian-developed combustion tunnel on Mir. Four 4.5-mm-diameter cylindrical samples of each plastic were ignited under concurrent airflow (in the direction of flame spread) with velocities from no flow to 8.5 cm/s. The test results identify a limiting air-flow velocity V(sub lim) for each material, below which combustion ceases. Nominal values are V(sub lim) < 0.3 cm/s for Delrin, 0.5 cm/s for PMMA, and 0.3 to 0.5 cm/s for polyethylene. These values are lower than those obtained in prior ground testing. Nevertheless, they demonstrate that flow shutoff is effective for extinguishment in the microgravity environment of spacecraft. Microgravity test results also show that the plastic materials maintain a stable melt ball within the spreading flame zone. In general, as the concurrent flow velocity V decreases, the flame-spread rate V(sub F) decreases, from an average (for all three materials) of V(sub F)= 0.5-0.75 mm/s at V = 8.5 cm/s to V(sub F)= 0.05-0.01 mm/s at V = 0.3-0.5 cm/s. Also, as V decreases, the flames become less visible but expand, increasing the probability of igniting an adjacent surface.

  12. A Parameter Study on the Effect of Impactor Size for NASA’s DART Mission

    NASA Astrophysics Data System (ADS)

    Truitt, Amanda; Weaver, Robert; Gisler, Galen

    2018-06-01

    We have modeled the impact of the Double Asteroid Redirection Test (DART) spacecraft into the binary near-Earth asteroid (65803) Didymos. While the primary object is approximately 800 meters across, its secondary body (“moonlet” Didymoon) has a diameter of 150 meters, which is thought to be a much more typical size for the kind of asteroid that would pose a hazard to Earth. DART will be the first demonstration of the kinetic impact technique to change the motion of an asteroid in space, an important consideration for understanding our capabilities in planetary defense of Near-Earth Asteroids. Recent modeling of this impact has used full-density solid aluminum spheres with a mass of approximately 500 kg. Many of the published scaling laws for crater size and diameter as well as ejecta modeling assume this type of impactor, although the actual spacecraft shape being considered for the DART Mission impact is not solid and does not contain a solid dedicated kinetic impactor – rather, the spacecraft itself is considered the impactor. Since the 500 kg hollow spacecraft is significantly larger (~100 x 100 x 200 cm) in size than a solid aluminum sphere (radius ~ 36 cm) the resulting impact dynamics are quite different. Here we have modeled both types of impacts and compare the results of the simulations for crater size, depth, and ejecta for a solid sphere (R = 36 cm) and cylindrical spacecraft (R = 20, 50, and 100 cm), while maintaining a constant mass and material density. This work will allow for a more robust comparison of the momentum enhancement β-factor, which describes the gain in a momentum transfer exerted by the impacting spacecraft on a Near-Earth Object due to ejecta momentum escape. (LA-UR-18-21571)

  13. [Selective breeding research on new cultivar "ChuanPeng 1" of Curcuma phaeocaulis].

    PubMed

    Xia, Qin; Yang, Zhao-wu; Li, Min; Xia, Dong-mei

    2014-11-01

    To breed a new good cultivar of Curcuma phaeocaulis. Three rounds of selection were systematically made for screening the new cultivar using biological technology. Firstly, individual plant selection. Promising individual plant selection was made based on the thousands of Curcuma phaeocaulis resources collected from all over the country. Secondly, strain selection. The promising strain was selected continually from the superior individuals on basis of specificities such as biological characteristics, yield, content of volatile oil and resistance. Thirdly, strain comparison test. The superior strain was selected through strain trial and regional trial. For the new cultivar "ChuanPeng 1" , its main rhizome was in ovoid or spindle shape, and it was fleshy and corpulent. Average amount of rhizome was 4, with 6. 27 cm in length and 3. 37 cm in diameter, while the secondary roots were cylindrical-like, with a yellow green cross section as the main rhizome. Slender root ends were inflated into the fleshy spindle shape, average amount of whose was 25, 3. 20 cm in length and 1. 33 cm in diameter with a yellow green or near white cross section. Average yield of rhizome is 5 314. 5 kg/hm2, while the root is 1 942. 5 kg/hm2, which was 32. 9% and 22. 7% higher than the local main cultivar respectively. The average extract content of rhizome was 15. 41% and content of volatile oil was 2. 82%, which was 15. 60% and 9. 30% higher than the local cultivar respectively. " ChuanPeng 1" has good stability and strong adaptability with high yield and superior internal quality. It can be cultivated and promoted in Jinma River Valley,Sichuan.

  14. Transition Induced by a Streamwise Array of Roughness Elements on a Supersonic Flat Plate

    NASA Technical Reports Server (NTRS)

    Chou, Amanda; Kegerise, Michael A.

    2017-01-01

    Roughness is unavoidable on practical high-speed vehicles, so it is critical to determine its impact on boundary layer transition. The flow field downstream of a streamwise array of cylindrical roughness elements is probed with hot-wire anemometry in this experiment. Mean flow distortion is examined in several measurement planes in the wake of the cylindrical roughness using the streak strength profiles and contour plots of the mass flux and total temperature. The roughness element heights and spacings were varied and their instability modes were examined. Cylindrical roughness elements approximately 140 micron tall produce an odd instability mode that grows weakly with downstream distance in the measurement range of this experiment. Cylindrical roughness elements approximately 280 micron tall produce an even instability mode that grows, becomes nonlinear, and then breaks down. Transition onset remains constant relative to the most downstream roughness in the streamwise array when the 280 micron roughness elements are spaced 2 diameters apart. Transition onset occurs at an earlier upstream location relative to the most downstream roughness in the streamwise array when the roughness elements are spaced 4 diameters appear to recover before the next downstream roughness element, so the location of transition shifts with the location of the most downstream roughness element in the array. When the rough- apart. The wake behind roughness elements spaced 2 diameters apart do not ness elements are spaced 4 diameters apart, the flow behind the first roughness element has enough space to recover before feeding into the second roughness element, and thus, moves transition forward.

  15. Studying the properties and response of a large volume (946 cm3) LaBr3:Ce detector with γ-rays up to 22.5 MeV

    NASA Astrophysics Data System (ADS)

    Mazumdar, I.; Gothe, D. A.; Anil Kumar, G.; Yadav, N.; Chavan, P. B.; Patel, S. M.

    2013-03-01

    This paper presents the results of our measurements and detailed simulations using GEANT4 to investigate the performance of a large volume (946 cm3) cylindrical (3.5 in.diameter×6 in.length) LaBr3:Ce detector. The properties of the detector have been studied using γ-rays from radioactive sources and in-beam reaction, from few hundred keV to 22.5 MeV. The salient features, which have been studied in-depth, are the uniformity and internal activity of the crystal, the energy and timing resolutions, linearity of the response up to 22.5 MeV, and efficiencies. A highly linear response has been observed by extracting the energy signal from a lower dynode and operating the PMT at a low voltage. The detector is to be primarily used for measuring high energy γ-rays spectra from Giant Dipole Resonance (GDR) decay studies.

  16. Surface Tension Driven Convection Experiment (STDCE)

    NASA Technical Reports Server (NTRS)

    Ostrach, S.; Kamotani, Y.

    1996-01-01

    This document reports the results obtained from the Surface Tension Driven Convection Experiment (STDCE) conducted aboard the USML-1 Spacelab in 1992. The experiments used 10 cSt silicone oil placed in an open circular container that was 10 cm wide and 5 cm deep. Thermocapillary flow was induced by using either a cylindrical heater placed along the container centerline or by a CO2 laser. The tests were conducted under various power settings, laser beam diameters, and free surface shapes. Thermistors located at various positions in the test section recorded the temperature of the fluid, heater, walls, and air. An infrared imager was used to measure the free surface temperature. The flow field was studied by flow visualization and the data was analyzed by a PTV technique. The results from the flow visualization and the temperature measurements are compared with the numerical analysis that was conducted in conjunction with the experiment. The compared results include the experimental and numerical velocity vector plots, the streamline plots, the fluid temperature, and the surface temperature distribution.

  17. Primary Dendrite Array Morphology: Observations from Ground-based and Space Station Processed Samples

    NASA Technical Reports Server (NTRS)

    Tewari, Surendra; Rajamure, Ravi; Grugel, Richard; Erdmann, Robert; Poirier, David

    2012-01-01

    Influence of natural convection on primary dendrite array morphology during directional solidification is being investigated under a collaborative European Space Agency-NASA joint research program, "Microstructure Formation in Castings of Technical Alloys under Diffusive and Magnetically Controlled Convective Conditions (MICAST)". Two Aluminum-7 wt pct Silicon alloy samples, MICAST6 and MICAST7, were directionally solidified in microgravity on the International Space Station. Terrestrially grown dendritic monocrystal cylindrical samples were remelted and directionally solidified at 18 K/cm (MICAST6) and 28 K/cm (MICAST7). Directional solidification involved a growth speed step increase (MICAST6-from 5 to 50 micron/s) and a speed decrease (MICAST7-from 20 to 10 micron/s). Distribution and morphology of primary dendrites is currently being characterized in these samples, and also in samples solidified on earth under nominally similar thermal gradients and growth speeds. Primary dendrite spacing and trunk diameter measurements from this investigation will be presented.

  18. Multi-shock Shield Performance at 16.5 MJ for Catalogued Debris

    NASA Technical Reports Server (NTRS)

    Miller, J. E.; Christiansen, E. L.; Davis, B. A.

    2014-01-01

    While orbital debris of ten centimeters or more are tracked and catalogued, the difficulty of finding and accurately accounting for forces acting on the objects near the ten centimeter threshold results in both uncertainty of their presence and location. These challenges result in difficult decisions for operators balancing potential costly operational approaches with system loss risk. In this paper, numerical simulations and an experiment using the multi-shock shield system is described for a cylindrical projectile composed of Nylon, aluminum and void that is approximately 8 cm in diameter and 10 cm in length weighing 670 g impacting the multi-shock shield normal to the surface with approximately 16.5 MJ of kinetic energy. The multi-shock shield system has been optimized to facilitate the fragmentation, spread and deceleration of the projectile remnants using hydrodynamic simulations of the impact event. The characteristics and function of each of the layers of the multi-shock system will be discussed along with considerations for deployment and improvement.

  19. Detection efficiency vs. cathode and anode separation in cylindrical vacuum photodiodes used for measuring x-rays from plasma focus device.

    PubMed

    Borthakur, T K; Talukdar, N; Neog, N K; Rao, C V S; Shyam, A

    2011-10-01

    A qualitative study on the performance of cylindrical vacuum photodiodes (VPDs) for x-ray detection in plasma focus device has been carried out. Various parameters of VPD such as electrode's diameter, electrode's separation, and its sensitivity are experimentally tested in plasma focus environment. For the first time it is found experimentally that the electrode-separation in the lateral direction of the two coaxial electrodes of cylindrical VPD also plays an important role to increase the efficiency of the detector. The efficiency is found to be highest for the detector with smaller cathode-anode lateral gap (1.5 mm) with smaller photo cathode diameter (10 mm). A comparison between our VPD with PIN (BPX-65) diode as an x-ray detector has also been made.

  20. Pipe support for use in a nuclear system

    DOEpatents

    Pollono, Louis P.; Mello, Raymond M.

    1977-01-01

    A pipe support for high temperature, thin-walled vertical piping runs used in a nuclear system. A cylindrical pipe transition member, having the same inside diameter as the thin-walled piping, replaces a portion of the piping where support is desired. The outside diameter of the pipe transition member varies axially along its vertical dimension. For a section of the axial length adjacent the upper and lower terminations of the pipe transition member, the outside diameter is the same as the outside diameter of the thin-walled piping to which it is affixed. Intermediate of the termination sections, the outside diameter increases from the top of the member to the bottom. Adjacent the lower termination section, the diameter abruptly becomes the same as the piping. Thus, the cylindrical transition member is formed to have a generally triangular shaped cross-section along the axial dimension. Load-bearing insulation is installed next to the periphery of the member and is kept in place by an outer ring clamp. The outer ring clamp is connected to pipe hangers, which provide the desired support for the vertical thin-walled piping runs.

  1. Photodynamic therapy for Barrett's esophagus using a 20-mm diameter light-delivery balloon

    NASA Astrophysics Data System (ADS)

    Panjehpour, Masoud; Overholt, Bergein F.; Phan, Mary N.; Haydek, John M.; Robinson, Amy R.

    2002-06-01

    Background and Objective: Patients with high grade dysplasia (HGD) in Barrett's esophagus are at a high risk for developing esophageal adenocarcinoma. Esophagectomy is the standard treatment for such patients. The objective of this study was to evaluate the safety and efficacy of photodynamic therapy (PDT) using an improved light delivery balloon for ablation of Barrett's esophagus with high grade dysplasia and/or early cancer. Materials and Methods: 20 patients with HGD or early cancer (19 with HGD, 1 with T1 cancer) received 2 mg/kg of porfimer sodium, intravenously. Two to three days after the injection, laser light was delivered using a cylindrical diffuser inserted inside a 20-mm diameter reflective esophageal PDT balloon. Initially, the balloon was inflated to a pressure of 80 mm Hg. The balloon pressure was gradually reduced to 30 mm Hg. A KTP/dye laser at 630 nm was used as the light source. Light dose of 115 J/cm was delivered at an intensity of 270 mw/cm. Nodules were pre- treated with an extra 50 J/cm using a short diffuser inserted through the scope. Patients were maintained on PPI therapy to keep the gastric pH higher than 4. Eighteen patients required one treatment, while two patients were treated twice. Follow-up consisted of endoscopy with four quadrant biopsies at every 2 cm of the treated area. Thermal ablation was used to treat small residual islands on the follow-ups. The follow-up endoscopies ranged from 6 to 17 months. Results: On follow-up endoscopy, 12 patients had complete replacement of their Barrett's mucosa with neosquamous mucosa. Five patients had residual non-dysplastic Barrett's mucosa, one had indefinite dysplasia, two had low grad dysplasia. There were no residual HGD or cancers. The average length of Barrett's was reduced from 5.4 cm to 1.2 cm. High balloon pressure resulted in wide variation in PDT response among patients. Lower balloon pressures resulted in more consistent destruction of Barrett's mucosa among patients. Five patients developed strictures which responded well to dilations. One patient developed atrial fibrillation which responded to medications. Conclusions: Photodynamic therapy using a 20 mm diameter balloon was effective for ablation of high grade dysplasia and early cancer in Barrett's esophagus. Low balloon inflation pressure was a critical parameter in producing consistent tissue destruction.

  2. Recirculation cells for granular flow in cylindrical rotating tumblers

    NASA Astrophysics Data System (ADS)

    D'Ortona, Umberto; Thomas, Nathalie; Lueptow, Richard M.

    2018-05-01

    To better understand the velocity field and flowing layer structure, we have performed a detailed discrete element method study of the flow of monodisperse particles in a partially filled three-dimensional cylindrical rotating tumblers. Similar to what occurs near the poles in spherical and conical tumblers, recirculation cells (secondary flows) develop near the flat endwalls of a cylindrical tumbler in which particles near the surface drift axially toward the endwall, while particles deeper in the flowing layer drift axially toward the midlength of the tumbler. Another recirculation cell with the opposite sense develops next to each endwall recirculation cell, extending to the midlength of the tumbler. For a long enough tumbler, each endwall cell is about one quarter of the tumbler diameter in length. Endwall cells are insensitive to tumbler length and relatively insensitive to rotation speed (so long as the flowing layer remains flat and continuously flowing) or fill level (from 25% to 50% full). However, for shorter tumblers (0.5 to 1.0 length/diameter aspect ratio) the endwall cell size does not change much, while center cells reduce their size and eventually disappear for the shortest tumblers. For longer tumblers (length/diameter aspect ratio larger than 2), a stagnation zone appears in between the central cells. These results provide insight into the mixing of monodisperse particles in rotating cylindrical tumblers as well as the frictional effects of the tumbler endwalls.

  3. Thrust and pumping characteristics of cylindrical ejectors using afterburning turbojet gas generator

    NASA Technical Reports Server (NTRS)

    Samanich, N. E.; Huntley, S. C.

    1969-01-01

    Static tests of cylindrical ejectors having ejector to primary diameter ratios from 1.1 to 1.6 and ejector length to primary nozzle diameter ratios from 0.9 to 2.1 are reported. Power setting of the J85-13 turbojet engine was varied from part power to maximum afterburning. Corrected secondary weight flow ratio was varied from 0.02 to 0.08 over a range of exhaust nozzle pressure ratios from 2.0 to 9.0. Secondary flow temperature rise and pressure drop characteristics through the nacelle secondary flow passage were also obtained.

  4. DSTO Landmine Detection Test Targets

    DTIC Science & Technology

    2005-06-01

    cm diameter, 10 cm high. x x GS 32D50 Galvanised steel, pipe, hollow, 32 cm diameter, 50 cm long, ends capped x x GS 45D50 Galvanised Steel, pipe...hollow, 45 cm diameter, 50 cm long, ends capped x x GS 75D50 Galvanised Steel, pipe, hollow, 75 cm diameter, 50 cm long, ends capped x x

  5. Hydraulic properties of coarsely and finely ground woodchips

    NASA Astrophysics Data System (ADS)

    Subroy, Vandana; Giménez, Daniel; Qin, Mingming; Krogmann, Uta; Strom, Peter F.; Miskewitz, Robert J.

    2014-09-01

    Recent evidence suggests that leachate from woodchips stockpiled at recycling facilities could negatively impact water quality. Models that can be used to simulate water movement/leachate production require information on water retention and hydraulic conductivity functions of the stockpiled material. The objectives of this study were to (1) determine water retention and hydraulic conductivity functions of woodchips with particle size distributions (PSDs) representative of field stockpiled material by modeling multistep outflow and (2) assess the performance of three pore structure models for their ability to simulate outflow. Six samples with contrasting PSDs were assessed in duplicate. Samples were packed in cylindrical columns (15.3 cm high, 12.1 cm wide) to measure saturated hydraulic conductivity (Ks), cumulative outflow and water content at equilibrium with pressure potentials of -2, -10 and -40 cm. Water retention at pressure potentials between -200 and -10,000 cm were obtained using pressure plate extractors and used to supplement data from the outflow experiment. Hydraulic parameters of the pore models were derived from these measurements using HYDRUS-1D run by DREAM(ZS). Ks was independent of PSD with values between 55 and 80 cm/h. Cumulative outflow at each pressure potential was correlated with the PSD geometric mean diameters, and was best predicted by a model having two interacting pore domains, each with separate hydraulic conductivity and water retention functions (DPeM). Unsaturated conductivities were predicted to drop on an average to 0.24 cm/h at -10 cm and 3 × 10-3 cm/h at -50 cm for the DPeM model, suggesting that water would move slowly through stockpiles except during intense rainfalls.

  6. Fast DNA sieving through submicrometer cylindrical glass capillary matrix.

    PubMed

    Cao, Zhen; Yobas, Levent

    2014-01-07

    Here, we report on DNA electrophoresis through a novel artificial sieving matrix based on the highly regular submicrometer cylindrical glass capillary segments alternatingly arranged with wells. Such round capillaries pose a higher-order confinement resulting in a lower partition coefficient and greater entropic energy barrier while limiting the driving field strength to a small fraction of the applied electric field. In return, the separation can be performed at high average field strengths (up to 1.6 kV/cm) without encountering the field-dependent loss of resolving power. This leads to fast DNA sieving as demonstrated here on the capillaries of 750 nm in diameter. The 600 bp to 21 kbp long chains are shown to resolve within 4 min after having undergone a fairly limited number of entropic barriers (128 in total). The capillary matrix also exhibits a critical field threshold below which DNA bands fail to launch, and this occurs at a considerably greater magnitude than in other matrixes. The submicrometer capillaries are batch-fabricated on silicon through a fabrication process that does not require high-resolution advanced lithography or well-controlled wafer bonding techniques to define their critical dimension.

  7. A new high-resolution PET scanner dedicated to brain research

    NASA Astrophysics Data System (ADS)

    Watanabe, M.; Shimizu, K.; Omura, T.; Takahashi, M.; Kosugi, T.; Yoshikawa, E.; Sato, N.; Okada, H.; Yamashita, T.

    2002-06-01

    A high-resolution positron emission tomography (PET) scanner dedicated to brain studies has been developed and its physical performance was evaluated. The block detector consists of a new compact position-sensitive photomultiplier tube (PS-PMT, Hamamatsu R7600-C12) and an 8/spl times/4 bismuth germanate (BGO) array. The size of each crystal is 2.8 mm/spl times/6.55 mm/spl times/30 mm. The system has a total of 11 520 crystals arranged in 24 detector rings 508 mm in diameter (480 per ring). The field of view (FOV) is 330 mm in diameter/spl times/163 mm, which is sufficient to measure the entire human brain. The diameter of the scanner's opening is equal to the transaxial FOV (330 mm). The system can be operated in three-dimensional (3-D) data acquisition mode, when the slice septa are retracted. The mechanical motions of the gantry and bed are specially designed to measure the patient in various postures; lying, sitting, and even standing postures. The spatial resolution of 2.9 mm in both the transaxial and axial directions is obtained at the center of the FOV. The total system sensitivity is 6.4 kc/s/kBq/ml in two-dimensional (2-D) mode, with a 20-cm-diameter cylindrical phantom. The imaging capabilities of the scanner were studied with the Hoffman brain phantom and with a normal volunteer.

  8. The study and development of the empirical correlations equation of natural convection heat transfer on vertical rectangular sub-channels

    NASA Astrophysics Data System (ADS)

    Kamajaya, Ketut; Umar, Efrizon; Sudjatmi, K. S.

    2012-06-01

    This study focused on natural convection heat transfer using a vertical rectangular sub-channel and water as the coolant fluid. To conduct this study has been made pipe heaters are equipped with thermocouples. Each heater is equipped with five thermocouples along the heating pipes. The diameter of each heater is 2.54 cm and 45 cm in length. The distance between the central heating and the pitch is 29.5 cm. Test equipment is equipped with a primary cooling system, a secondary cooling system and a heat exchanger. The purpose of this study is to obtain new empirical correlations equations of the vertical rectangular sub-channel, especially for the natural convection heat transfer within a bundle of vertical cylinders rectangular arrangement sub-channels. The empirical correlation equation can support the thermo-hydraulic analysis of research nuclear reactors that utilize cylindrical fuel rods, and also can be used in designing of baffle-free vertical shell and tube heat exchangers. The results of this study that the empirical correlation equations of natural convection heat transfer coefficients with rectangular arrangement is Nu = 6.3357 (Ra.Dh/x)0.0740.

  9. Effect of implant macro-design on primary stability: A prospective clinical study

    PubMed Central

    Lozano-Carrascal, Naroa; Salomó-Coll, Oscar; Gilabert-Cerdà, Marta; Farré-Pagés, Nuria; Hernández-Alfaro, Federico

    2016-01-01

    Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by registering insertion torque values (ITv) and ISQ values by means of Osstell™ Mentor (ISQv) (Integration Diagnostic Ltd., Goteborg, Sweden). Results In the mandible, mean ISQv for tapered implants (TI) was 71.67±5.16 and for cylindrical implants (CI) 57.15±4.83 (p=0.01). Mean insertion torque was 46.67±6.85 Ncm for TI and 35.77±6.72 Ncm for CI (p=0.01). In the maxilla, mean ISQ was 67.2±4.42 for tapered implants and 49.17±15.30 for cylindrical implants (p=0.01). Mean insertion torque for TI was 41.5±6.26 Ncm and for CI 39.17±6.34 Ncm (p>0.05). For tapered implants, no correlation could be found between implant diameter and primary stability. But for cylindrical implants there was a statistically significant correlation between implant diameter and primary stability: ITv (p=0.03); ISQv (p=0.04). Conclusions Within the limits of the present study, tapered shaped implants achieve higher primary stability measured through ISQ and insertion torque values. Moreover, for cylindrical implants positive correlation has been established between implant diameter and primary stability. Key words:Primary stability, tapered, cylindrical, conical, implant macro-design. PMID:26827067

  10. A simulation study of a C-shaped in-beam PET system for dose verification in carbon ion therapy

    NASA Astrophysics Data System (ADS)

    Jung An, Su; Beak, Cheol-Ha; Lee, Kisung; Hyun Chung, Yong

    2013-01-01

    The application of hadrons such as carbon ions is being developed for the treatment of cancer. The effectiveness of such a technique is due to the eligibility of charged particles in delivering most of their energy near the end of the range, called the Bragg peak. However, accurate verification of dose delivery is required since misalignment of the hadron beam can cause serious damage to normal tissue. PET scanners can be utilized to track the carbon beam to the tumor by imaging the trail of the hadron-induced positron emitters in the irradiated volume. In this study, we designed and evaluated (through Monte Carlo simulations) an in-beam PET scanner for monitoring patient dose in carbon beam therapy. A C-shaped PET and a partial-ring PET were designed to avoid interference between the PET detectors and the therapeutic carbon beam delivery. Their performance was compared with that of a full-ring PET scanner. The C-shaped, partial-ring, and full-ring scanners consisted of 14, 12, and 16 detector modules, respectively, with a 30.2 cm inner diameter for brain imaging. Each detector module was composed of a 13×13 array of 4.0 mm×4.0 mm×20.0 mm LYSO crystals and four round 25.4 mm diameter PMTs. To estimate the production yield of positron emitters such as 10C, 11C, and 15O, a cylindrical PMMA phantom (diameter, 20 cm; thickness, 20 cm) was irradiated with 170, 290, and 350 AMeV 12C beams using the GATE code. Phantom images of the three types of scanner were evaluated by comparing the longitudinal profile of the positron emitters, measured along the carbon beam as it passed a simulated positron emitter distribution. The results demonstrated that the development of a C-shaped PET scanner to characterize carbon dose distribution for therapy planning is feasible.

  11. Effect of implant macro-design on primary stability: A prospective clinical study.

    PubMed

    Lozano-Carrascal, Naroa; Salomó-Coll, Oscar; Gilabert-Cerdà, Marta; Farré-Pagés, Nuria; Gargallo-Albiol, Jordi; Hernández-Alfaro, Federico

    2016-03-01

    Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Mehods: A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers' standard protocols. Implant primary stability was measured at the moment of implant placement by registering insertion torque values (ITv) and ISQ values by means of Osstell™ Mentor (ISQv) (Integration Diagnostic Ltd., Goteborg, Sweden). In the mandible, mean ISQv for tapered implants (TI) was 71.67±5.16 and for cylindrical implants (CI) 57.15±4.83 (p=0.01). Mean insertion torque was 46.67±6.85 Ncm for TI and 35.77±6.72 Ncm for CI (p=0.01). In the maxilla, mean ISQ was 67.2±4.42 for tapered implants and 49.17±15.30 for cylindrical implants (p=0.01). Mean insertion torque for TI was 41.5±6.26 Ncm and for CI 39.17±6.34 Ncm (p>0.05). For tapered implants, no correlation could be found between implant diameter and primary stability. But for cylindrical implants there was a statistically significant correlation between implant diameter and primary stability: ITv (p=0.03); ISQv (p=0.04). Within the limits of the present study, tapered shaped implants achieve higher primary stability measured through ISQ and insertion torque values. Moreover, for cylindrical implants positive correlation has been established between implant diameter and primary stability.

  12. Macromolecular shape and interactions in layer-by-layer assemblies within cylindrical nanopores.

    PubMed

    Lazzara, Thomas D; Lau, K H Aaron; Knoll, Wolfgang; Janshoff, Andreas; Steinem, Claudia

    2012-01-01

    Layer-by-layer (LbL) deposition of polyelectrolytes and proteins within the cylindrical nanopores of anodic aluminum oxide (AAO) membranes was studied by optical waveguide spectroscopy (OWS). AAO has aligned cylindrical, nonintersecting pores with a defined pore diameter d(0) and functions as a planar optical waveguide so as to monitor, in situ, the LbL process by OWS. The LbL deposition of globular proteins, i.e., avidin and biotinylated bovine serum albumin was compared with that of linear polyelectrolytes (linear-PEs), both species being of similar molecular weight. LbL deposition within the cylindrical AAO geometry for different pore diameters (d(0) = 25-80 nm) for the various macromolecular species, showed that the multilayer film growth was inhibited at different maximum numbers of LbL steps (n(max)). The value of n(max) was greatest for linear-PEs, while proteins had a lower value. The cylindrical pore geometry imposes a physical limit to LbL growth such that n(max) is strongly dependent on the overall internal structure of the LbL film. For all macromolecular species, deposition was inhibited in native AAO, having pores of d(0) = 25-30 nm. Both, OWS and scanning electron microscopy showed that LbL growth in larger AAO pores (d(0) > 25-30 nm) became inhibited when approaching a pore diameter of d(eff,n_max) = 25-35 nm, a similar size to that of native AAO pores, with d(0) = 25-30 nm. For a reasonable estimation of d(eff,n_max), the actual volume occupied by a macromolecular assembly must be taken into consideration. The results clearly show that electrostatic LbL allowed for compact macromolecular layers, whereas proteins formed loosely packed multilayers.

  13. Background light measurements in the deep ocean

    NASA Astrophysics Data System (ADS)

    Aoki, T.; Kitamura, T.; Matsuno, S.; Mitsui, K.; Ohashi, Y.

    1986-04-01

    The ambient light intensity at depths from 1500 to 4700 m at the DUMAND site near Hawaii is determined experimentally. The instrument (two 5-inch-diameter hemispherical photomultiplier elements enclosed in a glass sphere filled with transparent silicon gel, a cylindrical stainless-steel electronics housing, and an A1/PVC frame) and the data-processing techniques are described, and the results of both ship-suspended and bottom-tethered deployments are presented in graphs and characterized. The bottom-tethered data are shown to be stable, and the absolute flux (218 + 20 or - 60 photons/sq cm s) at 4700 m is considered consistent with the beta decay of K-40. Higher and less stable intensities in the ship-suspended data are attributed to bioluminescence stimulated by the motion of the instrument.

  14. Echocolor Doppler morpho-functional study of the jugulo-subclavian confluence in chronic cerebro-spinal venous insufficiency and multiple sclerosis patients.

    PubMed

    Mandolesi, Sandro; d'Alessandro, Aldo; Desogus, Antonello Ignazio; Ciccone, Marco Matteo; Zito, Annapaola; Stammegna, Immacolata; Niglio, Tarcisio; Orsini, Augusto; Mandolesi, Dimitri; d'Alessandro, Alessandro; Revelli, Luca

    2017-01-01

    The aim of this work is to measure the mean diameter of the confluence jugulo- subclavian, the impact of different types of jugular confluences and the correlation between the types of confluences and the Valsalva maneuver (jugular reflux) in subjects with Chronic Cerebro-Spinal Venous Insufficiency (CCSVI) and Multiple Sclerosis. We investigated by Echo-Color-Doppler (ECD) 103 subjects (67 F 36M) of mean age 45 ± 12 years (a minimum of 22 to a maximum of 79 years, with a median of 44 and a modal value 42 years), mean EDSS of 4.7 and average disease duration of 12 years. The 103 right jugular veins investigated had an average diameter of 8.4 ± 2.4 mm (minimum 4.0, maximum 14.9 mm; median 7.9; modal value 7.6 mm). Three form types were found: 56 cylindrical, 29 conical and 18 funnel. Valsalva maneuver was positive in 30 patients. The 103 left jugular investigated had an average diameter of 8.9 ± 2.4 mm (minimum 2.8, maximum 14.4 mm; median of 8.8; modal value 8.7 mm). The form types were found: 42 cylindrical, 45 conical and 16 funnel. Valsalva maneuver was positive in 30 patients. The mean diameter of the jugular veins was 8.7 mm. Internal jugular veins with cylindrical morphology have a diameter smaller than other forms; this difference is statistically significant. The different morphology of the jugular vein confluence does not increase the possibility of a reflux because the positive Valsalva maneuvers are not statistically significant when compared to the various types. CCSVI, EchoColorDoppler Map, Jugulo-Subclavian Confluence Diameter.

  15. Winding for linear pump

    DOEpatents

    Kliman, G.B.; Brynsvold, G.V.; Jahns, T.M.

    1989-08-22

    A winding and method of winding for a submersible linear pump for pumping liquid sodium are disclosed. The pump includes a stator having a central cylindrical duct preferably vertically aligned. The central vertical duct is surrounded by a system of coils in slots. These slots are interleaved with magnetic flux conducting elements, these magnetic flux conducting elements forming a continuous magnetic field conduction path along the stator. The central duct has placed therein a cylindrical magnetic conducting core, this core having a cylindrical diameter less than the diameter of the cylindrical duct. The core once placed to the duct defines a cylindrical interstitial pumping volume of the pump. This cylindrical interstitial pumping volume preferably defines an inlet at the bottom of the pump, and an outlet at the top of the pump. Pump operation occurs by static windings in the outer stator sequentially conveying toroidal fields from the pump inlet at the bottom of the pump to the pump outlet at the top of the pump. The winding apparatus and method of winding disclosed uses multiple slots per pole per phase with parallel winding legs on each phase equal to or less than the number of slots per pole per phase. The slot sequence per pole per phase is chosen to equalize the variations in flux density of the pump sodium as it passes into the pump at the pump inlet with little or no flux and acquires magnetic flux in passage through the pump to the pump outlet. 4 figs.

  16. Winding for linear pump

    DOEpatents

    Kliman, Gerald B.; Brynsvold, Glen V.; Jahns, Thomas M.

    1989-01-01

    A winding and method of winding for a submersible linear pump for pumping liquid sodium is disclosed. The pump includes a stator having a central cylindrical duct preferably vertically aligned. The central vertical duct is surrounded by a system of coils in slots. These slots are interleaved with magnetic flux conducting elements, these magnetic flux conducting elements forming a continuous magnetic field conduction path along the stator. The central duct has placed therein a cylindrical magnetic conducting core, this core having a cylindrical diameter less than the diameter of the cylindrical duct. The core once placed to the duct defines a cylindrical interstitial pumping volume of the pump. This cylindrical interstitial pumping volume preferably defines an inlet at the bottom of the pump, and an outlet at the top of the pump. Pump operation occurs by static windings in the outer stator sequentially conveying toroidal fields from the pump inlet at the bottom of the pump to the pump outlet at the top of the pump. The winding apparatus and method of winding disclosed uses multiple slots per pole per phase with parallel winding legs on each phase equal to or less than the number of slots per pole per phase. The slot sequence per pole per phase is chosen to equalize the variations in flux density of the pump sodium as it passes into the pump at the pump inlet with little or no flux and acquires magnetic flux in passage through the pump to the pump outlet.

  17. Multiple scattering by infinitely long cylindrical glass inclusions in a saturated Biot porous medium of glass beads.

    PubMed

    Trabelsi, W; Franklin, H; Tinel, A

    2016-05-01

    The resonance spectrum of sets of two to five infinitely long parallel cylindrical glass inclusions in a fluid saturated porous matrix of unconsolidated glass beads is investigated. The ratio of bead diameters to inclusion diameters is 1/5. The far field form functions and the related phase derivatives are calculated by using an exact multiple scattering formalism and by assuming that the porous medium obeys Biot's model. In order to validate this hypothesis, comparisons between theory and experiments are done in the special case of a fast incident wave on a set of two and three inclusions.

  18. Simulation study of poled low-water ionomers with different architectures

    NASA Astrophysics Data System (ADS)

    Allahyarov, Elshad; Taylor, Philip L.; Löwen, Hartmut

    2011-11-01

    The role of the ionomer architecture in the formation of ordered structures in poled membranes is investigated by molecular dynamics computer simulations. It is shown that the length of the sidechain Ls controls both the areal density of cylindrical aggregates Nc and the diameter of these cylinders in the poled membrane. The backbone segment length Lb tunes the average diameter Ds of cylindrical clusters and the average number of sulfonates Ns in each cluster. A simple empirical formula is noted for the dependence of the number density of induced rod-like aggregates on the sidechain length Ls within the parameter range considered in this study.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Magie, Robert J.; Morris, Matthew S.; Ledgerwood, Richard D.

    In 2008, we sampled migrating juvenile Pacific salmonids Oncorhynchus spp. tagged with passive integrated transponder (PIT) tags using a surface pair trawl in the upper Columbia River estuary (rkm 61-83). The cod-end of the trawl was replaced with a cylindrical PIT-tag detection antenna with an 86-cm-diameter fish-passage opening and two detection coils connected in series. The pair trawl was 105 m long with a 91.5-m opening between the wings and a sample depth of 4.9 m. Also during 2008, we finalized the development of a prototype 'matrix' antenna, which was larger than previous antennas by a considerable magnitude. The matrixmore » antenna consisted of 6 coils: a 3-coil front component and a 3-coil rear component, which were separated by 1.5-m of net mesh. The fish-passage opening was 2.5 m wide by 3.0 m tall and was attached to a standard-size pair trawl net. Intermittent sampling with a single crew began on 7 March and targeted yearling Chinook salmon O. tshawytscha and steelhead O. mykiss. Daily sampling using two crews began on 30 April and continued through 14 June; during this period we detected 2.7% of all juvenile salmonids previously detected at Bonneville Dam--a measure of sample efficiency. Sampling with a single crew continued through 20 August and targeted subyearling Chinook salmon. We detected 7,397 yearling Chinook salmon, 2,735 subyearling Chinook salmon, 291 coho salmon O. kisutch, 5,950 steelhead, and 122 sockeye salmon O. nerka in the upper estuary. We deployed the matrix antenna system and the older, cylindrical antenna system (86-cm-diameter fish-passage opening) simultaneously in mid-May 2008 to test matrix detection efficiency. The cylindrical antenna system had been used successfully in 2007 and early 2008. Because distribution of migrating salmonids in the estuary changes rapidly, we felt that a tandem sampling effort between the two systems was the only way to truly evaluate comparative detection efficiency. We deployed both systems within 1 km of each other during a period of high fish densities on 13, 14, and 15 May. Detections of the matrix system surpassed those of the cylindrical system by 53% in 14 h of simultaneous sampling (total detections 716 and 339, respectively). We believe that the higher detection rate observed with the matrix system was due to fewer smolts escaping the trawl entrance and to more smolts readily passing through the larger fish-passage opening. After tandem sampling, we continued exclusive use of the matrix system for the remainder of the 2008 juvenile migration season. Mean survival rates from Lower Granite to Bonneville Dam for yearling Chinook salmon and steelhead were 42% (SE = 3.7%) and 46% (SE = 1.5%), respectively. Over 358,000 PIT-tagged salmonids were transported, and we detected 4,619 of these fish.« less

  20. Analysis of granular flow in a pebble-bed nuclear reactor.

    PubMed

    Rycroft, Chris H; Grest, Gary S; Landry, James W; Bazant, Martin Z

    2006-08-01

    Pebble-bed nuclear reactor technology, which is currently being revived around the world, raises fundamental questions about dense granular flow in silos. A typical reactor core is composed of graphite fuel pebbles, which drain very slowly in a continuous refueling process. Pebble flow is poorly understood and not easily accessible to experiments, and yet it has a major impact on reactor physics. To address this problem, we perform full-scale, discrete-element simulations in realistic geometries, with up to 440,000 frictional, viscoelastic 6-cm-diam spheres draining in a cylindrical vessel of diameter 3.5m and height 10 m with bottom funnels angled at 30 degrees or 60 degrees. We also simulate a bidisperse core with a dynamic central column of smaller graphite moderator pebbles and show that little mixing occurs down to a 1:2 diameter ratio. We analyze the mean velocity, diffusion and mixing, local ordering and porosity (from Voronoi volumes), the residence-time distribution, and the effects of wall friction and discuss implications for reactor design and the basic physics of granular flow.

  1. Experimental Evaluation of the Canadarm2 Residual Flexural Strength After an Orbital Debris Impact

    NASA Astrophysics Data System (ADS)

    Lanouette, Anne-Marie; Potvin, Marie-Josee; Martin, Francis; Mondor, Sylvain; Houle, Dany; Therriault, Daniel

    2014-06-01

    The risk for spacecraft structures of being hit by an orbital debris is constantly increasing due to the steadily augmenting number of objects sent to space while only a fraction of them are deorbited after use. Numerous studies have taken place to characterize the damage of a hypervelocity impact on a space structure; however the structural effect of such impact usually isn't investigated. Four cylindrical samples 35cm in diameter and 2.7mm in thickness of carbon fibers IM7/PEEK, representative of the Canadarm2 structure, covered by thermal blankets, have been subjected to hypervelocity impacts. Projectiles with diameters between 5.0 and 8.0mm and velocities between 6.9 and 7.2km/s were used for the tests. The visible and internal damage on the booms and on the thermal blankets was characterized. The damaged cylinders underwent fatigue bending loading with two different amplitudes to study the residual resistance of a laminate space structure after an orbital debris impact. Damage propagation was detected with the higher amplitude fatigue loading only.

  2. Magnetic properties of cylindrical diameter modulated Ni80Fe20 nanowires: interaction and coercive fields

    NASA Astrophysics Data System (ADS)

    Salem, Mohamed Shaker; Sergelius, Philip; Corona, Rosa M.; Escrig, Juan; Görlitz, Detlef; Nielsch, Kornelius

    2013-04-01

    Magnetic properties of cylindrical Ni80Fe20 nanowires with modulated diameters are investigated theoretically as a function of their geometrical parameters and compared with those produced inside the pores of anodic alumina membranes by pulsed electrodeposition. We observe that the Ni80Fe20 nanowires with modulated diameters reverse their magnetization via the nucleation and propagation of a vortex domain wall. The system begins generating vortex domains in the nanowire ends and in the transition region between the two segments to minimize magnetostatic energy generated by surfaces perpendicular to the initial magnetization of the sample. Besides, we observed an increase of the coercivity for the sample with equal volumes in relation to the sample with equal lengths. Finally, the interaction field is stronger in the case of constant volume segments. These structures could be used to control the motions of magnetic domain walls. In this way, these nanowires with modulated diameters can be an alternative to store information or even perform logic functions.

  3. Measurement of the photoneutron flux density distribution from cylindrical targets

    NASA Astrophysics Data System (ADS)

    Golovkov, V. M.; Basina, T. N.; Yakovlev, M. R.

    1989-09-01

    Measurements are performed of the density of photoneutron fluxes from cylindrical targets of2H2O (diameter 64 and height 86 mm), Be (outer diameter 70, inner diameter 40, height 100mm), and238U (diameter 44.5 mm, height 50 mm) under the action of braking radiation from electrons with energies of 4 to 8 MeV in order to determine the effect of target form and orientation relative to the detector upon the recorded photoneutron level. The fluxes were measured by an “all-wave” neutron detector based on an SNM-11 counter in a paraffin retarder at an angle of 90‡ to the axis of the braking radiation beam for various target orientations relative to the detector. Measurement results are compared to calculations. Photoneutron fluxes from heavy water and beryllium targets of the indicated dimensions were also measured for angles of 90, 135, and 167‡. An isotropic nature was noted in the photoneutron fluxes from both targets.

  4. Preliminary experimental results of tungsten wire-array Z-pinches on primary test stand

    NASA Astrophysics Data System (ADS)

    Huang, Xian-Bin; Zhou, Shao-Tong; Dan, Jia-Kun; Ren, Xiao-Dong; Wang, Kun-Lun; Zhang, Si-Qun; Li, Jing; Xu, Qiang; Cai, Hong-Chun; Duan, Shu-Chao; Ouyang, Kai; Chen, Guang-Hua; Ji, Ce; Wei, Bing; Feng, Shu-Ping; Wang, Meng; Xie, Wei-Ping; Deng, Jian-Jun; Zhou, Xiu-Wen; Yang, Yi

    2015-07-01

    The Primary Test Stand (PTS) developed at the China Academy of Engineering Physics is a 20 TW pulsed power driver, which can deliver a ˜10 MA, 70 ns rise-time (10%-90%) current to a short-circuit load and has important applications in Z-pinch driven inertial confinement fusion and high energy density physics. Preliminary results of tungsten wire-array Z-pinch experiments on PTS are presented. The load geometries investigated include 15-mm-tall cylindrical single and nested arrays with diameter ranging from 13 mm to 30 mm, consisting of 132-300 tungsten wires with 5-10 μm in diameter. Multiple diagnostics were fielded to characterize the x-ray radiation from wire-array Z pinches. The x-ray peak power (˜50 TW) and total radiated energy (˜500 kJ) were obtained from a single 20-mm-diam array with 80-ns stagnation time. The highest x-ray peak power up to 80 TW with 2.4 ns FWHM was achieved by using a nested array with 20-mm outer diameter, and the total x-ray energy from the nested array is comparable to that of single array. Implosion velocity estimated from the time-resolved image measurement exceeds 30 cm/μs. The detailed experimental results and other findings are presented and discussed.

  5. SU-G-JeP2-13: Spatial Accuracy Evaluation for Real-Time MR Guided Radiation Therapy Using a Novel Large-Field MRI Distortion Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antolak, A; Bayouth, J; Bosca, R

    Purpose: Evaluate a large-field MRI phantom for assessment of geometric distortion in whole-body MRI for real-time MR guided radiation therapy. Methods: A prototype CIRS large-field MRI distortion phantom consisting of a PMMA cylinder (33 cm diameter, 30 cm length) containing a 3D-printed orthogonal grid (3 mm diameter rods, 20 mm apart), was filled with 6 mM NiCl{sub 2} and 30 mM NaCl solution. The phantom was scanned at 1.5T and 3.0T on a GE HDxt and Discovery MR750, respectively, and at 0.35T on a ViewRay system. Scans were obtained with and without 3D distortion correction to demonstrate the impact ofmore » such corrections. CT images were used as a reference standard for analysis of geometric distortion, as determined by a fully automated gradient-search method developed in Matlab. Results: 1,116 grid points distributed throughout a cylindrical volume 28 cm in diameter and 16 cm in length were identified and analyzed. With 3D distortion correction, average/maximum displacements for the 1.5, 3.0, and 0.35T systems were 0.84/2.91, 1.00/2.97, and 0.95/2.37 mm, respectively. The percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (73%, 92%, 97%), (54%, 85%, 97%), and (55%, 90%, 99%), respectively. A reduced scan volume of 20 × 20 × 10 cm{sup 3} (representative of a head and neck scan volume) consisting of 420 points was also analyzed. In this volume, the percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (90%, 99%, 100%), (63%, 95%, 100%), and (75%, 96%, 100%), respectively. Without 3D distortion correction, average/maximum displacements were 1.35/3.67, 1.67/4.46, and 1.51/3.89 mm, respectively. Conclusion: The prototype large-field MRI distortion phantom and developed software provide a thorough assessment of 3D spatial distortions in MRI. The distortions measured were acceptable for RT applications, both for the high field strengths and the system configuration developed by ViewRay.« less

  6. Design of a Phase /Doppler Light-Scattering System for Measurement of Small-Diameter Glass Fibers During Fiberglass Manufacturing

    NASA Astrophysics Data System (ADS)

    Schaub, Scott A.; Naqwi, Amir A.; Harding, Foster L.

    1998-01-01

    We present fundamental studies examining the design of a phase /Doppler laser light-scattering system applicable to on-line measurements of small-diameter ( <15 m) fibers during fiberglass manufacturing. We first discuss off-line diameter measurement techniques currently used in the fiberglass industry and outline the limitations and problems associated with these methods. For the phase /Doppler design study we have developed a theoretical computer model for the response of the measurement system to cylindrical fibers, which is based on electromagnetic scattering theory. The model, valid for arbitrary fiber diameters and hardware configurations, generates simulated detector output as a function of time for a finite absorbing, cylindrical fiber oriented perpendicular to the two incident laser beams. Results of experimental measurements are presented, confirming predictions of the theoretical model. Parametric studies have also been conducted using the computer model to identify experimental arrangements that provide linear phase -diameter relationships for small-diameter fibers, within the measurement constraints imposed by the fiberglass production environment. The effect of variations in optical properties of the glass as well as fiber orientation effects are discussed. Through this research we have identified phase /Doppler arrangements that we expect to have future applications in the fiberglass industry for on-line diameter monitoring and process control.

  7. Design of a phase/doppler light-scattering system for measurement of small-diameter glass fibers during fiberglass manufacturing.

    PubMed

    Schaub, S A; Naqwi, A A; Harding, F L

    1998-01-20

    We present fundamental studies examining the design of a phase/Doppler laser light-scattering system applicable to on-line measurements of small-diameter (<15 mum) fibers during fiberglass manufacturing. We first discuss off-line diameter measurement techniques currently used in the fiberglass industry and outline the limitations and problems associated with these methods. For the phase/Doppler design study we have developed a theoretical computer model for the response of the measurement system to cylindrical fibers, which is based on electromagnetic scattering theory. The model, valid for arbitrary fiber diameters and hardware configurations, generates simulated detector output as a function of time for a finite absorbing, cylindrical fiber oriented perpendicular to the two incident laser beams. Results of experimental measurements are presented, confirming predictions of the theoretical model. Parametric studies have also been conducted using the computer model to identify experimental arrangements that provide linear phase-diameter relationships for small-diameter fibers, within the measurement constraints imposed by the fiberglass production environment. The effect of variations in optical properties of the glass as well as fiber orientation effects are discussed. Through this research we have identified phase/Doppler arrangements that we expect to have future applications in the fiberglass industry for on-line diameter monitoring and process control.

  8. Cylindrical fabric-confined soil structures

    NASA Astrophysics Data System (ADS)

    Harrison, Richard A.

    A cylindrical fabric-soil structural concept for implementation on the moon and Mars which provides many advantages is proposed. The most efficient use of fabric is to fashion it into cylindrical tubes, creating cylindrical fabric-confined soil structures. The length, diameter, and curvature of the tubes will depend on the intended application. The cylindrical hoop forces provide radial confinement while end caps provide axial confinement. One of the ends is designed to allow passage of the soil into the fabric tube before sealing. Transportation requirements are reduced due to the low mass and volume of the fabric. Construction requirements are reduced due to the self-erection capability via the pneumatic exoskeleton. Maintenance requirements are reduced due to the passive nature of the concept. The structure's natural ductility is well suited for any seismic activity.

  9. Three Dimensionally Interlinked, Dense, Solid Form of Single-Walled CNT Ropes

    NASA Technical Reports Server (NTRS)

    Smalley, Richard E.

    2012-01-01

    A 3D networked, dense form of single-walled carbon nanotubes (SWNT) has been made through isotropic shrinking of a gel-like SWNT-water paste by very slow evaporation. Approximately 35 g of Raw HiPco nanotubes were cleaned by the method of soft baking (250 C for 15 hours in air saturated with water vapor) in a glass beaker followed by leaching with concentrated hydrochloric acid. Typically, one liter of concentrated hydrochloric acid was added to the soft-baked voluminous mass in the same large beaker, and allowed to digest at room temperature with stirring overnight. The acid-digested SWNT slurry was filtered through a large porcelain Buchner funnel under atmospheric pressure. The slurry was continuously flushed, while still in the funnel, with a very slow but steady stream of deionized water employing a peristaltic pump. This process, referred to as gwashing, h continued until the filtrate water dripping from the Buchner funnel was clear, colorless, and neutral to a pH paper. This took about 15 liters of water to flow through the slurry over a day. At this point, the water pump was stopped and the SWNT-water slurry was allowed to drain the excess water for about 10 hours. The resulting thick paste of SWNT-neutral water was transferred to a beaker. The beaker was covered with aluminum foil with few holes and allowed to dry very slowly in a hood at room temperature. In about eight weeks, the sample gradually dried isotropically to a cylindrical dense mass referred to as a carbon nanotube block (CNB). There was no carbonaceous matter sticking to any of the glass surface where the SWNT-water paste made contact. The approximate dimensions of the cylindrical SWNT block that weighed 28 g were 1.5 in. (.3.8 cm) in diameter and 1.25 in. (.3.2 cm) in height. The bottom portion of the cylinder that was in contact with the beaker surface was slightly wider, indicating some resistance to shrinking. The cylindrical mass also consisted of several pores. The cylindrical mass was very tough and could not be broken with a small hammer using considerable force. The mass of the solid could be polished over a fine grain emery paper or even a smooth, stainless steel surface indicative of alignment at finer levels.

  10. Liquid inflow to a baffled cylindrical tank during weightlessness

    NASA Technical Reports Server (NTRS)

    Staskus, J. V.

    1972-01-01

    An experimental investigation was conducted in which the behavior of liquid inflow to a cylindrical tank containing inlet baffles was observed during weightlessness. A single tank radius (2 cm), inlet radius (0.2 cm), and liquid (ethanol)were used. The inlet end of the tank was hemispherical with a 30 deg convergent inlet. All the baffle configurations tested were cylindrically symmetric and mounted coaxially with the tank within the hemispherical end. Both stable and unstable inflow behavior were observed using each baffle. It was found that, depending on which of the baffles was used, the critical inflow velocity at which a transition to unstable inflow began was from 2.5 to 12 times greater than the corresponding velocity in an unbaffled tank.

  11. An investigation of kV CBCT image quality and dose reduction for volume-of-interest imaging using dynamic collimation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parsons, David, E-mail: david.parsons@dal.ca, E-mail: james.robar@cdha.nshealth.ca; Robar, James L., E-mail: david.parsons@dal.ca, E-mail: james.robar@cdha.nshealth.ca

    2015-09-15

    Purpose: The focus of this work was to investigate the improvements in image quality and dose reduction for volume-of-interest (VOI) kilovoltage-cone beam CT (CBCT) using dynamic collimation. Methods: A prototype iris aperture was used to track a VOI during a CBCT acquisition. The current aperture design is capable of 1D translation as a function of gantry angle and dynamic adjustment of the iris radius. The aperture occupies the location of the bow-tie filter on a Varian On-Board Imager system. CBCT and planar image quality were investigated as a function of aperture radius, while maintaining the same dose to the VOI,more » for a 20 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Corresponding scatter-to-primary ratios (SPR) were determined at the detector plane with Monte Carlo simulation using EGSnrc. Dose distributions for various sizes VOI were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field distributions. Results: SPR was reduced by a factor of 8.4 when decreasing iris diameter from 21.2 to 2.4 cm (at isocenter). Depending upon VOI location and size, dose was reduced to 16%–90% of the full-field value along the central axis plane and down to 4% along the axis of rotation, while maintaining the same dose to the VOI compared to full-field techniques. When maintaining constant dose to the VOI, this change in iris diameter corresponds to a factor increase of approximately 1.6 in image contrast and a factor decrease in image noise of approximately 1.2. This results in a measured gain in contrast-to-noise ratio by a factor of approximately 2.0. Conclusions: The presented VOI technique offers improved image quality for image-guided radiotherapy while sparing the surrounding volume of unnecessary dose compared to full-field techniques.« less

  12. Tracer Movement in a Single Fissure in Granitic Rock: Some Experimental Results and Their Interpretation

    NASA Astrophysics Data System (ADS)

    Neretnieks, Ivars; Eriksen, Tryggve; TäHtinen, PäIvi

    1982-08-01

    Radionuclide migration was studied in a natural fissure in a granite core. The fissure was oriented parallel to the axis in a cylindrical core 30 cm long and 20 cm in diameter. The traced solution was injected at one end of the core and collected at the other. Breakthrough curves were obtained for the nonsorbing tracers, tritiated water, and a large-molecular-weight lignosulphonate molecule and for the sorbing tracers, cesium and strontium. From the breakthrough curves for the nonsorbing tracers it could be concluded that channeling occurs in the single fissure. A `dispersion' model based on channeling is presented. The results from the sorbing tracers indicate that there is substantial diffusion into and sorption in the rock matrix. Sorption on the surface of the fissure also accounts for a part of the retardation effect of the sorbing species. A model which includes the mechanisms of channeling, surface sorption, matrix diffusion, and matrix sorption is presented. The experimental breakthrough curves can be fitted fairly well by this model by use of independently obtained data on diffusivities and matrix sorption.

  13. Status of MSBS Study at NAL in 1995

    NASA Technical Reports Server (NTRS)

    Sawada, Hideo; Suenaga, Hisasi; Kunimasu, Tetuya; Kohno, Takashi

    1996-01-01

    Magnetic field intensity and currents passing through the coils of the National Aerospace Laboratory (NAL) 1O cm Magnetic Suspension and Balance System (MSBS) were measured while a cylindrical model was oscillated along x,y,z and also about y and z axes, respectively. The model was made of alnico 5 and was 8 mm in diameter and 60 mm long. Two kinds of tests were carried out. Amplitude of the oscillation was varied at a frequency of 10 Hz. Frequency was varied from 1 to 50 Hz in the other test. Results of the tests show that the relation between coil currents and magnetic force acting on the model is affected by frequency. They also show that the relation between measured magnetic field intensity and the force in vertical direction is independent of the frequency below 30 Hz. Using the measured magnetic field intensity, the vertical force can be evaluated at the MSBS instantaneously when a model moves at frequencies below 30 Hz. A static drag force calibration test was carried out at the 60 cm MSBS. Obtained relationships between measured drag coil currents and loads shows large hysteresis.

  14. MAGIC polymer gel for dosimetric verification in boron neutron capture therapy

    PubMed Central

    Heikkinen, Sami; Kotiluoto, Petri; Serén, Tom; Seppälä, Tiina; Auterinen, Iiro; Savolainen, Sauli

    2007-01-01

    Radiation‐sensitive polymer gels are among the most promising three‐dimensional dose verification tools developed to date. We tested the normoxic polymer gel dosimeter known by the acronym MAGIC (methacrylic and ascorbic acid in gelatin initiated by copper) to evaluate its use in boron neutron capture therapy (BNCT) dosimetry. We irradiated a large cylindrical gel phantom (diameter: 10 cm; length: 20 cm) in the epithermal neutron beam of the Finnish BNCT facility at the FiR 1 nuclear reactor. Neutron irradiation was simulated with a Monte Carlo radiation transport code MCNP. To compare dose–response, gel samples from the same production batch were also irradiated with 6 MV photons from a medical linear accelerator. Irradiated gel phantoms then underwent magnetic resonance imaging to determine their R2 relaxation rate maps. The measured and normalized dose distribution in the epithermal neutron beam was compared with the dose distribution calculated by computer simulation. The results support the feasibility of using MAGIC gel in BNCT dosimetry. PACS numbers: 87.53.Qc, 87.53.Wz, 87.66.Ff PMID:17592463

  15. The feasibility of polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: a Monte Carlo study.

    PubMed

    Jones, Bernard L; Cho, Sang Hyun

    2011-06-21

    A recent study investigated the feasibility to develop a bench-top x-ray fluorescence computed tomography (XFCT) system capable of determining the spatial distribution and concentration of gold nanoparticles (GNPs) in vivo using a diagnostic energy range polychromatic (i.e. 110 kVp) pencil-beam source. In this follow-up study, we examined the feasibility of a polychromatic cone-beam implementation of XFCT by Monte Carlo (MC) simulations using the MCNP5 code. In the current MC model, cylindrical columns with various sizes (5-10 mm in diameter) containing water loaded with GNPs (0.1-2% gold by weight) were inserted into a 5 cm diameter cylindrical polymethyl methacrylate phantom. The phantom was then irradiated by a lead-filtered 110 kVp x-ray source, and the resulting gold fluorescence and Compton-scattered photons were collected by a series of energy-sensitive tallies after passing through lead parallel-hole collimators. A maximum-likelihood iterative reconstruction algorithm was implemented to reconstruct the image of GNP-loaded objects within the phantom. The effects of attenuation of both the primary beam through the phantom and the gold fluorescence photons en route to the detector were corrected during the image reconstruction. Accurate images of the GNP-containing phantom were successfully reconstructed for three different phantom configurations, with both spatial distribution and relative concentration of GNPs well identified. The pixel intensity of regions containing GNPs was linearly proportional to the gold concentration. The current MC study strongly suggests the possibility of developing a bench-top, polychromatic, cone-beam XFCT system for in vivo imaging.

  16. Track structure model of microscopic energy deposition by protons and heavy ions in segments of neuronal cell dendrites represented by cylinders or spheres

    PubMed Central

    Alp, Murat; Cucinotta, Francis A.

    2017-01-01

    Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (>100 μm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3He and 12C particles at energies corresponding to a distance of 1 cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch. PMID:28554507

  17. Track structure model of microscopic energy deposition by protons and heavy ions in segments of neuronal cell dendrites represented by cylinders or spheres

    NASA Astrophysics Data System (ADS)

    Alp, Murat; Cucinotta, Francis A.

    2017-05-01

    Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (> 100 μm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3He and 12C particles at energies corresponding to a distance of 1 cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch.

  18. Track structure model of microscopic energy deposition by protons and heavy ions in segments of neuronal cell dendrites represented by cylinders or spheres.

    PubMed

    Alp, Murat; Cucinotta, Francis A

    2017-05-01

    Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (> 100µm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3 He and 12 C particles at energies corresponding to a distance of 1cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch. Copyright © 2017. Published by Elsevier Ltd.

  19. Optimization of the Magnetic Field Structure for Sustained Plasma Gun Helicity Injection for Magnetic Turbulence Studies at the Bryn Mawr Plasma Laboratory

    NASA Astrophysics Data System (ADS)

    Cartagena-Sanchez, C. A.; Schaffner, D. A.; Johnson, H. K.; Fahim, L. E.

    2017-10-01

    A long-pulsed magnetic coaxial plasma gun is being implemented and characterized at the Bryn Mawr Plasma Laboratory (BMPL). A cold cathode discharged between the cylindrical electrodes generates and launches plasma into a 24cm diameter, 2m long chamber. Three separately pulsed magnetic coils are carefully positioned to generate radial magnetic field between the electrodes at the gun edge in order to provide stuffing field. Magnetic helicity is continuously injected into the flux-conserving vacuum chamber in a process akin to sustained slow-formation of spheromaks. The aim of this source, however, is to supply long pulses of turbulent magnetized plasma for measurement rather than for sustained spheromak production. The work shown here details the optimization of the magnetic field structure for this sustained helicity injection.

  20. Disassembly time of deuterium-cluster-fusion plasma irradiated by an intense laser pulse.

    PubMed

    Bang, W

    2015-07-01

    Energetic deuterium ions from large deuterium clusters (>10nm diameter) irradiated by an intense laser pulse (>10(16)W/cm(2)) produce DD fusion neutrons for a time interval determined by the geometry of the resulting fusion plasma. We present an analytical solution of this time interval, the plasma disassembly time, for deuterium plasmas that are cylindrical in shape. Assuming a symmetrically expanding deuterium plasma, we calculate the expected fusion neutron yield and compare with an independent calculation of the yield using the concept of a finite confinement time at a fixed plasma density. The calculated neutron yields agree quantitatively with the available experimental data. Our one-dimensional simulations indicate that one could expect a tenfold increase in total neutron yield by magnetically confining a 10-keV deuterium fusion plasma for 10ns.

  1. The sizing of hamstring grafts for anterior cruciate reconstruction: intra- and inter-observer reliability.

    PubMed

    Dwyer, Tim; Whelan, Daniel B; Khoshbin, Amir; Wasserstein, David; Dold, Andrew; Chahal, Jaskarndip; Nauth, Aaron; Murnaghan, M Lucas; Ogilvie-Harris, Darrell J; Theodoropoulos, John S

    2015-04-01

    The objective of this study was to establish the intra- and inter-observer reliability of hamstring graft measurement using cylindrical sizing tubes. Hamstring tendons (gracilis and semitendinosus) were harvested from ten cadavers by a single surgeon and whip stitched together to create ten 4-strand hamstring grafts. Ten sports medicine surgeons and fellows sized each graft independently using either hollow cylindrical sizers or block sizers in 0.5-mm increments—the sizing technique used was applied consistently to each graft. Surgeons moved sequentially from graft to graft and measured each hamstring graft twice. Surgeons were asked to state the measured proximal (femoral) and distal (tibial) diameter of each graft, as well as the diameter of the tibial and femoral tunnels that they would drill if performing an anterior cruciate ligament (ACL) reconstruction using that graft. Reliability was established using intra-class correlation coefficients. Overall, both the inter-observer and intra-observer agreement were >0.9, demonstrating excellent reliability. The inter-observer reliability for drill sizes was also excellent (>0.9). Excellent correlation was seen between cylindrical sizing, and drill sizes (>0.9). Sizing of hamstring grafts by multiple surgeons demonstrated excellent intra-observer and intra-observer reliability, potentially validating clinical studies exploring ACL reconstruction outcomes by hamstring graft diameter when standard techniques are used. III.

  2. The incidence and effect of noncylindrical neck morphology on outcomes after endovascular aortic aneurysm repair in the Global Registry for Endovascular Aortic Treatment.

    PubMed

    Shutze, William; Suominem, Velipekka; Jordan, William; Cao, Piergiorgio; Oweida, Steven; Milner, Ross

    2018-05-23

    The Gore Global Registry for Endovascular Aortic Treatment (GREAT) was designed to evaluate real-world outcomes after treatment with Gore aortic endografts used in a real-world, global setting. We retrospectively analyzed the GREAT data to evaluate the incidence and effects of noncylindrical neck anatomy in patients undergoing endovascular aortic aneurysm repair. The present analysis included patients with data in the GREAT who had been treated with the EXCLUDER endograft from August 2010 to October 2016. A noncylindrical neck was defined when the proximal aortic landing zone diameter had changed ≥2 mm over the first 15 mm of the proximal landing zone, indicating a tapered, conical, or hourglass morphology. Cox multivariate regression analyses were performed for any reintervention (including reinterventions on aortic branch vessels), device-related reinterventions, and reintervention specifically for endoleak. Independent binary (cylindrical vs noncylindrical necks) and continuous (percentage of neck diameter change) variables were assessed. The abdominal aortic aneurysm (AAA) diameter, proximal neck length, maximal infrarenal neck angle, gender, and use of aortic extender cuffs were also assessed. Of 3077 GREAT patients with available proximal aortic landing zone diameter measurements available, 1765 were found to have cylindrical necks and 1312 had noncylindrical necks. The noncylindrical neck cohort had a significantly greater proportion of women (17.4% vs 12.6%; P < .001) and more severe infrarenal angulation (33.8° vs 28.4°; P < .001). A total 14.7% of noncylindrical neck patients and 11.2% cylindrical neck patients underwent implantation outside of the EXCLUDER instructions for use regarding the anatomic inclusion criteria (P = .004). The procedural characteristics were similar between the two cohorts; however, noncylindrical neck patients required significantly more aortic extender cuffs (P = .004). The average follow-up was 21.2 ± 17.5 months and 17.8 ± 15.8 months for the cylindrical and noncylindrical cohorts, respectively (P < .001). The Cox multivariate regression models demonstrated female gender and maximum AAA diameter were significant risk factors for subsequent reintervention (overall, device-related, and endoleak-specific). Women were 2.2 times as likely to require device-related intervention during the follow-up period compared with men (P < .001). Neck shape morphology was not a significant predictor, except for device-related intervention, for which cylindrical necks (binary definition) resulted in a slightly elevated risk (1.5 times; P = .03). Noncylindrical neck morphology was more common in women and was associated with an increased use of aortic extender cuffs but did not increase the risk of intervention. Female gender and AAA diameter were associated with an increased need for reintervention. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  3. Preliminary results from the Small Negative Ion Facility (SNIF) at CCFE

    NASA Astrophysics Data System (ADS)

    Zacks, J.; McAdams, R.; Booth, J.; Flinders, K.; Holmes, A. J. T.; Simmonds, M.; Stevens, B.; Stevenson, P.; Surrey, E.; Warder, S.; Whitehead, A.; Young, D.

    2013-02-01

    At Culham Centre for Fusion Energy, a new beam extraction test facility has been built with the purpose of studying and enhancing negative ion beam production and transport. The multipole hydrogen ion source is based on a RF generated plasma using a continuous 5kW power supply operating at the industrial standard frequency of 13.56MHz. The cylindrical source has a diameter of 30cm and a depth of 20cm, with a flat spiral antenna driving the source through a quartz window. The magnet configuration is arranged to produce a dipole filter field across the ion source close to the plasma grid. The plasma load is matched to the RF generator using a Pi matching network. The accelerator uses a single extraction aperture of 14mm diameter, with a biased insert for electron suppression. The accelerator is a triode design with a beam energy of up to 30kV. The beamline consists of a turbomolecular pumped vacuum tank with an instrumented beam dump and ports for additional diagnostics. The ITER Neutral Beam source operates with the enhancement of caesium, which, when scaled up to a reactor, will be heavily consumed. The small size of SNIF allows for fast turn around of modifications and alternative materials to caesium can be tested. A full description of the facility and planned diagnostics is given. Initial results are presented, including measurements and calculations of the plasma load on the RF generator, and beam extraction measurements.

  4. New Cryogenic Optical Test Capability at Marshall Space Flight Center's Space Optics Manufacturing Technology Center

    NASA Technical Reports Server (NTRS)

    Kegley, Jeff; Burdine, Robert V. (Technical Monitor)

    2002-01-01

    A new cryogenic optical testing capability exists at Marshall Space Flight Center's Space Optics Manufacturing Technology Center (SOMTC). SOMTC has been performing optical wavefront testing at cryogenic temperatures since 1999 in the X-ray Cryogenic Test Facility's (XRCF's) large vacuum chamber. Recently the cryogenic optical testing capability has been extended to a smaller vacuum chamber. This smaller horizontal cylindrical vacuum chamber has been outfitted with a helium-cooled liner that can be connected to the facility's helium refrigeration system bringing the existing kilowatt of refrigeration capacity to bear on a 1 meter diameter x 2 meter long test envelope. Cryogenic environments to less than 20 Kelvin are now possible in only a few hours. SOMTC's existing instruments (the Instantaneous Phase-shifting Interferometer (IPI) from ADE Phase-Shift Technologies and the PhaseCam from 4D Vision Technologies) view the optic under test through a 150 mm clear aperture BK-7 window. Since activation and chamber characterization tests in September 2001, the new chamber has been used to perform a cryogenic (less than 30 Kelvin) optical test of a 22.5 cm diameter x 127 cm radius of curvature Si02 mirror, a cryogenic survival (less than 30 Kelvin) test of an adhesive, and a cryogenic cycle (less than 20 Kelvin) test of a ULE mirror. A vibration survey has also been performed on the test chamber. Chamber specifications and performance data, vibration environment data, and limited test results will be presented.

  5. New Cryogenic Optical Test Capability at Marshall Space Flight Center's Space Optics Manufacturing Technology Center

    NASA Technical Reports Server (NTRS)

    Kegley, Jeff; Stahl, H. Philip (Technical Monitor)

    2002-01-01

    A new cryogenic optical testing capability exists at Marshall Space Flight Center's Space Optics Manufacturing Technology Center (SOMTC). SOMTC has been performing optical wavefront testing at cryogenic temperatures since 1999 in the X-ray Cryogenic Test Facility's (XRCF's) large vacuum chamber. Recently the cryogenic optical testing capability has been extended to a smaller vacuum chamber. This smaller horizontal cylindrical vacuum chamber has been outfitted with a helium-cooled liner that can be connected to the facility's helium refrigeration system bringing the existing kilowatt of refrigeration capacity to bear on a 1 meter diameter x 2 meter long test envelope. Cryogenic environments to less than 20 Kelvin are now possible in only a few hours. SOMTC's existing instruments (the Instantaneous Phase-shifting Interferometer (IPI) from ADE Phase-Shift Technologies and the PhaseCam from 4D Vision Technologies) view the optic under test through a 150 mm clear aperture BK-7 window. Since activation and chamber characterization tests in September 2001, the new chamber has been used to perform a cryogenic (less than 30 Kelvin) optical test of a 22.5 cm diameter x 127 cm radius of curvature SiO2 mirror, a cryogenic survival (less than 30 Kelvin) test of an adhesive, and a cryogenic cycle (less than 20 Kelvin) test of a ULE mirror. A vibration survey has also been performed on the test chamber. Chamber specifications and performance data, vibration environment data, and limited test results will be presented.

  6. Pinhole X-ray fluorescence imaging of gadolinium and gold nanoparticles using polychromatic X-rays: a Monte Carlo study

    PubMed Central

    Jung, Seongmoon; Sung, Wonmo; Ye, Sung-Joon

    2017-01-01

    This work aims to develop a Monte Carlo (MC) model for pinhole K-shell X-ray fluorescence (XRF) imaging of metal nanoparticles using polychromatic X-rays. The MC model consisted of two-dimensional (2D) position-sensitive detectors and fan-beam X-rays used to stimulate the emission of XRF photons from gadolinium (Gd) or gold (Au) nanoparticles. Four cylindrical columns containing different concentrations of nanoparticles ranging from 0.01% to 0.09% by weight (wt%) were placed in a 5 cm diameter cylindrical water phantom. The images of the columns had detectable contrast-to-noise ratios (CNRs) of 5.7 and 4.3 for 0.01 wt% Gd and for 0.03 wt% Au, respectively. Higher concentrations of nanoparticles yielded higher CNR. For 1×1011 incident particles, the radiation dose to the phantom was 19.9 mGy for 110 kVp X-rays (Gd imaging) and 26.1 mGy for 140 kVp X-rays (Au imaging). The MC model of a pinhole XRF can acquire direct 2D slice images of the object without image reconstruction. The MC model demonstrated that the pinhole XRF imaging system could be a potential bioimaging modality for nanomedicine. PMID:28860750

  7. Hypoxia interface behavior of the ctenophore Mnemiopsis leidyi

    NASA Astrophysics Data System (ADS)

    Gentry, L. A.; Moss, A.

    2016-02-01

    The ctenophore Mnemiopsis leidyi is most widely known as a destructive invasive species of the Black and Caspian seas. Ctenophores are also found endemically in oceans worldwide, where their low oxygen tolerances allow many of them to use hypoxic zones to escape predation and hunt disabled prey. Ctenophores have also been observed in the wild and laboratory conditions associating with the interface of hypoxic and normoxic waters, allowing them to feed on the organisms found there. In order to test the ability of M. leidyi to find oxygen interfaces, a 10 cm diameter X 60 cm tall cylindrical tank was designed with a sharp oxycline (<1cm) in the middle, stabilized by a 1 ppt salinity difference. The hypoxic water was produced by nitrogen bubbling prior to the experiment. We found that animals introduced to the tank under oxycline conditions increased their time spent at the interface by over nearly five-fold versus those in a fully normoxic or hypoxic water. These preliminary results would indicate that M. leidyi preferentially associates with the interfaces of hypoxic zones. As human effects such as overfishing, nutrient enrichment of coastal waters, and invasive introduction continue to rise, the complex interactions of these animals and hypoxic zones will become increasingly important to planktonic and pelagic ecosystems worldwide.

  8. Weight and volume equations and tables for six upland hardwoods in southern Illinois.

    Treesearch

    David J. Polak; Donald Raisanen; Richard C. Schlesinger; Les Stortz

    1980-01-01

    This paper presents tables of total tree green weight, green weight to a 5 cm and a 10 cm top diameter, dry weight to both 5 cm and 10 cm top diameter, and green volume to a 5 cm and 10 cm top diameter for six upland hardwood species. Both metric and English unit tables are included.

  9. Stagnation Region Heat Transfer Augmentation at Very High Turbulence Levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ames, Forrest; Kingery, Joseph E.

    A database for stagnation region heat transfer has been extended to include heat transfer measurements acquired downstream from a new high intensity turbulence generator. This work was motivated by gas turbine industry heat transfer designers who deal with heat transfer environments with increasing Reynolds numbers and very high turbulence levels. The new mock aero-combustor turbulence generator produces turbulence levels which average 17.4%, which is 37% higher than the older turbulence generator. The increased level of turbulence is caused by the reduced contraction ratio from the liner to the exit. Heat transfer measurements were acquired on two large cylindrical leading edgemore » test surfaces having a four to one range in leading edge diameter (40.64 cm and 10.16 cm). Gandvarapu and Ames [1] previously acquired heat transfer measurements for six turbulence conditions including three grid conditions, two lower turbulence aero-combustor conditions, and a low turbulence condition. The data are documented and tabulated for an eight to one range in Reynolds numbers for each test surface with Reynolds numbers ranging from 62,500 to 500,000 for the large leading edge and 15,625 to 125,000 for the smaller leading edge. The data show augmentation levels of up to 136% in the stagnation region for the large leading edge. This heat transfer rate is an increase over the previous aero-combustor turbulence generator which had augmentation levels up to 110%. Note, the rate of increase in heat transfer augmentation decreases for the large cylindrical leading edge inferring only a limited level of turbulence intensification in the stagnation region. The smaller cylindrical leading edge shows more consistency with earlier stagnation region heat transfer results correlated on the TRL (Turbulence, Reynolds number, Length scale) parameter. The downstream regions of both test surfaces continue to accelerate the flow but at a much lower rate than the leading edge. Bypass transition occurs in these regions providing a useful set of data to ground the prediction of transition onset and length over a wide range of Reynolds numbers and turbulence intensity and scales.« less

  10. Performance evaluation of a slow-release packing material-embedded functional microorganisms for biofiltration.

    PubMed

    Zhu, Rencheng; Li, Shunyi; Wu, Zhenjun; Dumont, Éric

    2017-04-01

    A composite packing material (CM-5) was prepared in this study, mainly consisting of compost with functional microorganisms, calcium carbonate (CaCO 3 ), perlite, cement and plant fiber. To get stronger compressive strength, mass ratios of these components were optimized based on single factor experiments, and finally adding amounts of perlite, cement, plant fiber, CaCO 3 , compost and binder at 18%, 18%, 7%, 13%, 17% and 27%, respectively. According to the optimum proportion, CM-5 was extruded in cylindrical shape (12 mm in diameter and 20 mm in length) with a bulk density of 470 kg m -3 , a moisture retention capacity of 49% and the microbial counts of × 10 5 CFU g -1 of packing material. The cumulative release rates of total organic carbon (TOC) and total nitrogen (TN) from CM-5 were 3.1% and 6.5%, respectively, after 19 times extraction in distilled water. To evaluate the H 2 S removal capacity, CM-5 was compared with an organic (corncob) and an inorganic (ceramsite) packing material in three biofilters. The results showed that CM-5 had higher H 2 S removal capacity compared with corncob and ceramsite. CM-5 could avoid the large fluctuation of pH value and pressure drop during the operation. The maximum H 2 S removal capacity of CM-5 was 12.9 g m -3  h -1 and the removal efficiency could maintain over 95.4% when the inlet H 2 S loading rate was lower than 11.3 g m -3  h -1 without any addition of nutrients and pH buffer substances. Besides, only 2-3 days were needed for the recovery of biofiltration performance after about two weeks of idle period.

  11. Macrosegregation in Al-7Si alloy caused by abrupt cross-section change during directional solidification

    NASA Astrophysics Data System (ADS)

    Ghods, M.; Johnson, L.; Lauer, M.; Grugel, R. N.; Tewari, S. N.; Poirier, D. R.

    2016-09-01

    Hypoeutectic Al-7 wt .% Si alloys were directionally solidified vertically downward in cylindrical molds that incorporated an abrupt cross-section decrease (9.5 mm to 3.2 mm diameter) which, after 5 cm, reverted back to 9.5 mm diameter in a Bridgman furnace; two constant growth speeds and thermal gradients were investigated. Thermosolutal convection and cross-section-change-induced shrinkage flow effects on macrosegregation were investigated. Dendrite clustering and extensive radial macrosegregation was seen, particularly in the larger cross-sections, before contraction and after expansion, this more evident at the lower growth speed. This alloy shows positive longitudinal macrosegregation near cross-section decrease followed by negative macrosegregation right after it; the extent of macrosegregation, however, decreases with increasing growth speed. Primary dendrite steepling intensified as solidification proceeded into the narrower section and negative longitudinal macrosegregation was seen on the re-entrant shelves at expansion. A two-dimensional model accounting for both shrinkage and thermo-solutal convection was used to simulate solidification and the resulting mushy-zone steepling and macrosegregation. The experimentally observed longitudinal and radial macrosegregation associated with the cross-section changes during directional solidification of an Al-7Si alloy is well captured by the numerical simulations.

  12. How They (Should Have) Built the Pyramids

    NASA Astrophysics Data System (ADS)

    Gallagher, Gregory; West, Joseph; Waters, Kevin

    2014-03-01

    A novel ``polygon method'' is proposed for moving large stone blocks. The method is implemented by the attachment of rods of analytically chosen radii to the block by means of rope. The chosen rods are placed on each side of the square-prism block in order to transform the square prism into a prism of higher order polygon, i.e. octagon, dodecagon etc. Experimental results are presented and compared to other methods proposed by the authors, including a dragging method and a rail method which includes the idea of dragging the block on rails made from arbitrarily chosen rod-shaped ``tracks,'' and to independent work by another group which utilized wooden attachments providing a cylindrical shape. It is found that the polygon method when used on small scale stone blocks across level open ground has an equivalent of a coefficient of friction order of 0.1. For full scale pyramid blocks, the wooden ``rods'' would need to be of order 30 cm in diameter, certainly within reason, given the diameter of wooden masts used on ships in that region during the relevant time period in Egypt. This project also inspired a ``spin-off'' project in which the behavior or rolling polygons is investigated and preliminary data is presented.

  13. Primary experimental results of wire-array Z-pinches on PTS

    NASA Astrophysics Data System (ADS)

    Huang, X. B.; Zhou, S. T.; Ren, X. D.; Dan, J. K.; Wang, K. L.; Zhang, S. Q.; Li, J.; Xu, Q.; Cai, H. C.; Duan, S. C.; Ouyang, K.; Chen, G. H.; Ji, C.; Wang, M.; Feng, S. P.; Yang, L. B.; Xie, W. P.; Deng, J. J.

    2014-12-01

    The Primary Test Stand (PTS) developed at the China Academy of Engineering Physics is a multiterawatt pulsed power driver, which can deliver a ˜10 MA, 70 ns rise-time (10%-90%) current to a short circuit load and has important applications in Z-pinch driven inertial confinement fusion and high energy density physics. In this paper, primary results of tungsten wire-array Z-pinch experiments on PTS are presented. The load geometries investigated include 15-mm-tall cylindrical single and nested arrays with diameter ranging from 14.4-26.4 mm, and consisting of 132˜276 tungsten wires with 5˜10 μm in diameter. Multiple diagnostics were fielded to determine the characteristics of x-ray radiations and to obtain self-emitting images of imploding plasmas. X-ray power up to 80 TW with ˜3 ns FWMH is achieved by using nested wire arrays. The total x-ray energy exceeds 500 kJ and the peak radiation temperature is about 150 eV. Typical velocity of imploding plasmas goes around 3˜5×107 cm/s and the radial convergence ratio is between 10 and 20.

  14. Radiation characteristics and implosion dynamics of tungsten wire array Z-pinches on the YANG accelerator

    NASA Astrophysics Data System (ADS)

    Huang, Xian-Bin; Yang, Li-Bing; Li, Jing; Zhou, Shao-Tong; Ren, Xiao-Dong; Zhang, Si-Qun; Dan, Jia-Kun; Cai, Hong-Chun; Duan, Shu-Chao; Chen, Guang-Hua; Zhang, Zheng-Wei; Ouyang, Kai; Li, Jun; Zhang, Zhao-Hui; Zhou, Rong-Guo; Wang, Gui-Lin

    2012-05-01

    We investigated the radiation characteristics and implosion dynamics of low-wire-number cylindrical tungsten wire array Z-pinches on the YANG accelerator with a peak current 0.8-1.1 MA and a rising time ~ 90 ns. The arrays are made up of (8-32) × 5 μm wires 6/10 mm in diameter and 15 mm in height. The highest X-ray power obtained in the experiments was about 0.37 TW with the total radiation energy ~ 13 kJ and the energy conversion efficiency ~ 9% (24 × 5 μm wires, 6 mm in diameter). Most of the X-ray emissions from tungsten Z-pinch plasmas were distributed in the spectral band of 100-600 eV, peaked at 250 and 375 eV. The dominant wavelengths of the wire ablation and the magneto-Rayleigh—Taylor instability were found and analyzed through measuring the time-gated self-emission and laser interferometric images. Through analyzing the implosion trajectories obtained by an optical streak camera, the run-in velocities of the Z-pinch plasmas at the end of the implosion phase were determined to be about (1.3-2.1) × 107 cm/s.

  15. Rheology of welding: experimental constraints

    NASA Astrophysics Data System (ADS)

    Quane, S. L.; Russell, J. K.; Kennedy, L. A.

    2003-04-01

    The rheological behavior of pyroclastic deposits during welding is incompletely understood and is based on a surprisingly small number of experimental studies. Previous pioneering experimental studies were done on small (1 cm thick) samples of ash/crystal mixtures under constant load. They established minimum welding temperatures between 600 and 700^oC under loads of 0.7 MPa (˜40 m of ignimbrite) to 3.6 MPa (˜250 m depth of ignimbrite). However, these data are neither sufficiently comprehensive nor coherent enough to fully describe the rheology of pyroclastic mixtures. In addition, previous studies did not examine the microstructural and geometric changes associated with welding compaction. Our goal is to provide accurate and comprehensive constitutive relationships between material properties, temperature, load and strain rate for pyroclastic material undergoing welding. Here we present results from a newly designed experimental apparatus. The experimental apparatus consists of a LoadTrac II fully automated uniaxial compression load frame manufactured by Geocomp Corporation. The load frame has a built in displacement transducer and can run both constant strain rate (10-6 to 0.25 cm/s) and constant load (up to 1150 kg) tests to a maximum displacement of 7.5 cm. The sample assembly comprises 5 cm diameter cylindrical upper and lower pistons (insulating ceramic with steel conductive ends) housed in a copper jacket. Samples are 5 cm diameter cores and can vary in length from 1 to 15 cm depending on experimental needs. A fiber insulated tube furnace capable of reaching temperatures ≈1000^oC surrounds the sample assembly. Temperature is measured using a thermocouple located inside the sample through the bottom piston; the furnace controller is capable of maintaining temperature fluctuations to <5^oC. Deformation experiments are performed on pre-fabricated cylinders of soda-lime glass beads and rhyolitic volcanic ash, as well as, cores of pumiceous rhyodacite. Experimental runs use strain rates of 10-4 and 10-5 cm/s and loads of ˜0 to 4.5 MPa. Experiments are run at temperatures between 400 and 850^oC corresponding to below and above the calorimetric glass transition temperatures of the respective materials. Data deriving from constant load and constant strain rate experiments are being used to constrain rheological models for welding of pyroclastic material.

  16. Spectral Analysis of the Shuttle Glow. AIS Science Support

    DTIC Science & Technology

    1992-06-23

    Prism (Total Internal Cylindrical Mirror Lens Reflection) Cylindrical Folding \\ Lens Plane Mirror -Cylindrical Slt Slit Mirror Fig. 7. Cron section...on Zerodur blanks, which width of the FOV to 0.14’ outward from the lens. have a coefficient of thermal expansion near zero. The width of the grating...oummambne toathe window of the iMag hunte~air. 3002. APPLIED OPTICS I VOL 3 .No, 16 / I June I02 68 Vacondry Minrror Prmr Mirror -luterence rlZters cm

  17. The Development of a Pirani Vacuum Gauge with a Platinum Wire in the J-PARC 3-GeV Rapid Cycling Synchrotron

    NASA Astrophysics Data System (ADS)

    Ogiwara, Norio; Hikichi, Yusuke; Yoshinari, Yoji

    The back pressure of Turbo-Molecular Pumps (TMPs) is constantly monitored using Pirani gauges at J-PARC (Japan Proton Accelerator Complex) RCS (3-GeV Rapid Cycling Synchrotron) where they are used not only in rough pumping but also evacuations during beam operations. The gauge head needs to be very resistant to vibration and abrupt air inlet etc. in minimizing exposure to radiation during maintenance and hence a 50 μm in diameter W wire was adopted as the filament. This type of Pirani gauge has worked well in monitoring the back pressure of the TMP but it has become difficult to measure the low pressure of less than several Pa with the gauge, which may have been due to changes in the emissivity of the W surface. An attempt was therefore made to develop a gauge head made of Pt wire in allowing pressures as low as 0.1 Pa to be measured. Platinum is one of the best possible materials to use because it is very stable against oxidization. However, ordinary Pt gauge heads are rather weak when it comes to vibrations and abrupt air inlet due to its low tensile strength. In order to improve its toughness the filament was composed of twelve 100 μm in diameter Pt wires that were 65 mm long, resulting in it being capable of enduring a force of 25 N. All the wires were welded in series on metal poles in two separate glass plates, with the poles being electrically insulated. This resulted in the filament, 78 cm long and about 10 Ω at room temperature, being containable in a 5 cm in diameter and 10 cm long cylindrical envelope. The output from the gauge head was then examined as a function of pressure under constant current as the plan was for it to be controlled using the constant current method. Confirmation then took place that the pressures of 0.1 Pa up to 103 Pa were measurable with the gauge using current control in such way that the set value increased with pressure increases in three stages.

  18. Innovative grinding wheel design for cost-effective machining of advanced ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Licht, R.H.; Kuo, P.; Liu, S.

    2000-05-01

    This Final Report covers the Phase II Innovative Grinding Wheel (IGW) program in which Norton Company successfully developed a novel grinding wheel for cost-effective cylindrical grinding of advanced ceramics. In 1995, Norton Company successfully completed the 16-month Phase I technical effort to define requirements, design, develop, and evaluate a next-generation grinding wheel for cost-effective cylindrical grinding of advanced ceramics using small prototype wheels. The Phase II program was initiated to scale-up the new superabrasive wheel specification to larger diameters, 305-mm to 406-mm, required for most production grinding of cylindrical ceramic parts, and to perform in-house and independent validation grinding tests.

  19. Helical Turing patterns in the Lengyel-Epstein model in thin cylindrical layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bánsági, T.; Taylor, A. F., E-mail: A.F.Taylor@sheffield.ac.uk

    2015-06-15

    The formation of Turing patterns was investigated in thin cylindrical layers using the Lengyel-Epstein model of the chlorine dioxide-iodine-malonic acid reaction. The influence of the width of the layer W and the diameter D of the inner cylinder on the pattern with intrinsic wavelength l were determined in simulations with initial random noise perturbations to the uniform state for W < l/2 and D ∼ l or lower. We show that the geometric constraints of the reaction domain may result in the formation of helical Turing patterns with parameters that give stripes (b = 0.2) or spots (b = 0.37) in two dimensions. For b = 0.2, the helices weremore » composed of lamellae and defects were likely as the diameter of the cylinder increased. With b = 0.37, the helices consisted of semi-cylinders and the orientation of stripes on the outer surface (and hence winding number) increased with increasing diameter until a new stripe appeared.« less

  20. Interaction of Highly Underexpanded Jets with Simulated Lunar Surfaces

    NASA Technical Reports Server (NTRS)

    Stitt, Leonard E.

    1961-01-01

    Pressure distributions and erosion patterns on simulated lunar surfaces (hard and soft) and interference effects between the surface and two representative lunar vehicles (cylindrical and spherical) were obtained with cold-air jets at various descent heights and nozzle total-pressure ratios up to 288,000. Surface pressure distributions were dependent on both nozzle area ratio and, nozzle contour. Peak pressures obtained with a sonic nozzle agreed closely with those predicted theoretically for a near-sonic jet expanding into a vacuum. Short bell-shaped nozzles gave annular pressure distributions; the low center pressure resulted from the coalescence of shocks that originated within the nozzle. The high surface pressures were contained within a circle whose diameter was about 16 throat diameters, regardless of nozzle area ratio or contour. The peak pressure increased rapidly as the vehicle approached the surface; for example, at a descent height of 40 throat diameters the peak pressure was 0.4 percent of the chamber pressure, but increased to 6 percent at 13 throat diameters. The exhaust jet eroded a circular concave hole in white sand at descent heights from about 200 to 600 throat diameters. The hole diameter was about 225 throat diameters, while the depth was approximately 60 throat diameters. The sand particles, which formed a conical sheet at a semivertex angle of 50 deg, appeared to follow a ballistic trajectory and at no time struck the vehicle. An increase in pressure was measured on the base of the cylindrical lunar vehicle when it approached to within 14 throat diameters of the hard, flat surface. No interference effects were noted between the spherical model and the surface to descent heights as low as 8 throat diameters.

  1. Performance Assessment of a Large Scale Pulsejet- Driven Ejector System

    NASA Technical Reports Server (NTRS)

    Paxson, Daniel E.; Litke, Paul J.; Schauer, Frederick R.; Bradley, Royce P.; Hoke, John L.

    2006-01-01

    Unsteady thrust augmentation was measured on a large scale driver/ejector system. A 72 in. long, 6.5 in. diameter, 100 lb(sub f) pulsejet was tested with a series of straight, cylindrical ejectors of varying length, and diameter. A tapered ejector configuration of varying length was also tested. The objectives of the testing were to determine the dimensions of the ejectors which maximize thrust augmentation, and to compare the dimensions and augmentation levels so obtained with those of other, similarly maximized, but smaller scale systems on which much of the recent unsteady ejector thrust augmentation studies have been performed. An augmentation level of 1.71 was achieved with the cylindrical ejector configuration and 1.81 with the tapered ejector configuration. These levels are consistent with, but slightly lower than the highest levels achieved with the smaller systems. The ejector diameter yielding maximum augmentation was 2.46 times the diameter of the pulsejet. This ratio closely matches those of the small scale experiments. For the straight ejector, the length yielding maximum augmentation was 10 times the diameter of the pulsejet. This was also nearly the same as the small scale experiments. Testing procedures are described, as are the parametric variations in ejector geometry. Results are discussed in terms of their implications for general scaling of pulsed thrust ejector systems

  2. An analysis of steady/unsteady electroosmotic flows through charged cylindrical nano-channels

    NASA Astrophysics Data System (ADS)

    Nayak, A. K.

    2013-11-01

    The steady/unsteady electroosmotic flow in an infinitely extended cylindrical channel with diameters ranging from 10 to 100 nm has been investigated. A mixture of (NaCl + H2O) is considered for the numerical calculation of the mass, potential, velocity, and mixing efficiency. Results are obtained for the channel diameters are small, equal, or greater than the electric double layer (EDL) both for steady and unsteady cases. In the present discussion, a symmetrical distribution of mole fractions is considered at the wall interface. Hence, the velocity and potential are symmetrical in nature toward the centerline of the channel, and also identical in nature at maximum and minimum time levels (i.e., at π/2 and 3 π/2 for a periodic function) in the transient case. In case of steady flows, the velocity and potential satisfy the chemical equilibrium condition at the centerline. It is observed that the electric double layer reaches a local equilibrium in the presence of electroosmosis when the channel length is long compared to the characteristic hydraulic diameter and the flow is essentially one-dimensional, which depends only on channel diameter. Comparisons of NP (Nernst Plank) model with PB (Poisson-Boltzmann) model are achieved out for different published results at larger channel diameters.

  3. Apparatus and method for plasma processing of SRF cavities

    NASA Astrophysics Data System (ADS)

    Upadhyay, J.; Im, Do; Peshl, J.; Bašović, M.; Popović, S.; Valente-Feliciano, A.-M.; Phillips, L.; Vušković, L.

    2016-05-01

    An apparatus and a method are described for plasma etching of the inner surface of superconducting radio frequency (SRF) cavities. Accelerator SRF cavities are formed into a variable-diameter cylindrical structure made of bulk niobium, for resonant generation of the particle accelerating field. The etch rate non-uniformity due to depletion of the radicals has been overcome by the simultaneous movement of the gas flow inlet and the inner electrode. An effective shape of the inner electrode to reduce the plasma asymmetry for the coaxial cylindrical rf plasma reactor is determined and implemented in the cavity processing method. The processing was accomplished by moving axially the inner electrode and the gas flow inlet in a step-wise way to establish segmented plasma columns. The test structure was a pillbox cavity made of steel of similar dimension to the standard SRF cavity. This was adopted to experimentally verify the plasma surface reaction on cylindrical structures with variable diameter using the segmented plasma generation approach. The pill box cavity is filled with niobium ring- and disk-type samples and the etch rate of these samples was measured.

  4. LSSA large area silicon sheet task continuous Czochralski process development

    NASA Technical Reports Server (NTRS)

    Rea, S. N.

    1978-01-01

    A Czochralski crystal growing furnace was converted to a continuous growth facility by installation of a premelter to provide molten silicon flow into the primary crucible. The basic furnace is operational and several trial crystals were grown in the batch mode. Numerous premelter configurations were tested both in laboratory-scale equipment as well as in the actual furnace. The best arrangement tested to date is a vertical, cylindrical graphite heater containing small fused silicon test tube liner in which the incoming silicon is melted and flows into the primary crucible. Economic modeling of the continuous Czochralski process indicates that for 10 cm diameter crystal, 100 kg furnace runs of four or five crystals each are near-optimal. Costs tend to asymptote at the 100 kg level so little additional cost improvement occurs at larger runs. For these conditions, crystal cost in equivalent wafer area of around $20/sq m exclusive of polysilicon and slicing was obtained.

  5. Hugoniot Measurements at Low Pressures in Tin Using 800 MeV proton Radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, Cynthia; Hogan, Gary E; King, Nicholas S. P.

    2009-08-05

    A 2cm long 8 mm diameter cylindrical tin target has been shocked to a pressure in the region of the {beta} {yields} {gamma} phase change using a small, low density PETN charge mounted on the opposite side of a stainless steel diaphragm. The density jump and shock velocity were measured radiographically as the shock wave moved through the sample and the pressure dropped, using the proton radiography facility at LANL. This provided a quasi-continuous record of the equations of state along the Hugoniot for the P1 wave from a shock velocity of 3.25 km/sec down to near the sound speed.more » Edge release effects were removed from the data using tomographic techniques. The data show evidence for a phase transition that extends over a broad pressure range. The data and analysis will be presented.« less

  6. Large area plasma source

    NASA Technical Reports Server (NTRS)

    Foster, John (Inventor); Patterson, Michael (Inventor)

    2008-01-01

    An all permanent magnet Electron Cyclotron Resonance, large diameter (e.g., 40 cm) plasma source suitable for ion/plasma processing or electric propulsion, is capable of producing uniform ion current densities at its exit plane at very low power (e.g., below 200 W), and is electrodeless to avoid sputtering or contamination issues. Microwave input power is efficiently coupled with an ionizing gas without using a dielectric microwave window and without developing a throat plasma by providing a ferromagnetic cylindrical chamber wall with a conical end narrowing to an axial entrance hole for microwaves supplied on-axis from an open-ended waveguide. Permanent magnet rings are attached inside the wall with alternating polarities against the wall. An entrance magnet ring surrounding the entrance hole has a ferromagnetic pole piece that extends into the chamber from the entrance hole to a continuing second face that extends radially across an inner pole of the entrance magnet ring.

  7. Central Drift Chamber for Belle-II

    NASA Astrophysics Data System (ADS)

    Taniguchi, N.

    2017-06-01

    The Central Drift Chamber (CDC) is the main device for tracking and identification of charged particles for Belle-II experiment. The Belle-II CDC is cylindrical wire chamber with 14336 sense wires, 2.3 m-length and 2.2 m-diameter. The wire chamber and readout electronics have been completely replaced from the Belle CDC. The new readout electronics system must handle higher trigger rate of 30 kHz with less dead time at the design luminosity of 8 × 1035 cm-2s-1. The front-end electronics are located close to detector and send digitized signal through optical fibers. The Amp-Shaper-Discriminator chips, FADC and FPGA are assembled on a single board. Belle-II CDC with readout electronics has been installed successfully in Belle structure in October 2016. We will present overview of the Belle-II CDC and status of commissioning with cosmic ray.

  8. Disassembly time of deuterium-cluster-fusion plasma irradiated by an intense laser pulse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bang, W.

    Energetic deuterium ions from large deuterium clusters (>10 nm diameter) irradiated by an intense laser pulse (>10¹⁶ W/cm²) produce DD fusion neutrons for a time interval determined by the geometry of the resulting fusion plasma. We show an analytical solution of this time interval, the plasma disassembly time, for deuterium plasmas that are cylindrical in shape. Assuming a symmetrically expanding deuterium plasma, we calculate the expected fusion neutron yield and compare with an independent calculation of the yield using the concept of a finite confinement time at a fixed plasma density. The calculated neutron yields agree quantitatively with the availablemore » experimental data. Our one-dimensional simulations indicate that one could expect a tenfold increase in total neutron yield by magnetically confining a 10 - keV deuterium fusion plasma for 10 ns.« less

  9. Disassembly time of deuterium-cluster-fusion plasma irradiated by an intense laser pulse

    DOE PAGES

    Bang, W.

    2015-07-02

    Energetic deuterium ions from large deuterium clusters (>10 nm diameter) irradiated by an intense laser pulse (>10¹⁶ W/cm²) produce DD fusion neutrons for a time interval determined by the geometry of the resulting fusion plasma. We show an analytical solution of this time interval, the plasma disassembly time, for deuterium plasmas that are cylindrical in shape. Assuming a symmetrically expanding deuterium plasma, we calculate the expected fusion neutron yield and compare with an independent calculation of the yield using the concept of a finite confinement time at a fixed plasma density. The calculated neutron yields agree quantitatively with the availablemore » experimental data. Our one-dimensional simulations indicate that one could expect a tenfold increase in total neutron yield by magnetically confining a 10 - keV deuterium fusion plasma for 10 ns.« less

  10. Performance of 10-kW class xenon ion thrusters

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.; Rawlin, Vincent K.

    1988-01-01

    Presented are performance data for laboratory and engineering model 30 cm-diameter ion thrusters operated with xenon propellant over a range of input power levels from approximately 2 to 20 kW. Also presented are preliminary performance results obtained from laboratory model 50 cm-diameter cusp- and divergent-field ion thrusters operating with both 30 cm- amd 50 cm-diameter ion optics up to a 20 kW input power. These data include values of discharge chamber propellant and power efficiencies, as well as values of specific impulse, thruster efficiency, thrust and power. The operation of the 30 cm- and 50 cm-diameter ion optics are also discussed.

  11. Mechanical properties of friction stir welded butt joint of steel/aluminium alloys: effect of tool geometry

    NASA Astrophysics Data System (ADS)

    Syafiq, W. M.; Afendi, M.; Daud, R.; Mazlee, M. N.; Majid, M. S. Abdul; Lee, Y. S.

    2017-10-01

    This paper described the mechanical properties from hardness testing and tensile testing of Friction Stir Welded (FSW) materials. In this project, two materials of aluminium and steel are welded using conventional milling machine and tool designed with different profile and shoulder size. During welding the temperature along the weld line is collected using thermocouples. Threaded pins was found to produce stronger joints than cylindrical pins. 20 mm diameter shoulder tool welded a slightly stronger joint than 18 mm diameter one, as well as softer nugget zone due to higher heat input. Threaded pins also contributed to higher weld temperature than cylindrical pins due to increase in pin contact surface. Generally, higher temperatures were recorded in aluminium side due to pin offset away from steel.

  12. Computational Analysis Supporting the Design of a New Beamline for the Mines Neutron Radiography Facility

    NASA Astrophysics Data System (ADS)

    Wilson, C.; King, J.

    The Colorado School of Mines installed a neutron radiography system at the United States Geological Survey TRIGA reactor in 2012. An upgraded beamline could dramatically improve the imaging capabilities of this system. This project performed computational analyses to support the design of a new beamline, with the major goals of minimizing beam divergence and maximizing beam intensity. The new beamline will consist of a square aluminum tube with an 11.43 cm (4.5 in) inner side length and 0.635 cm (0.25 in) thick walls. It is the same length as the original beam tube (8.53 m) and is composed of 1.22 m (4 ft) and 1.52 m (5 ft) flanged sections which bolt together. The bottom 1.22 m of the beamline is a cylindrical aluminum pre-collimator which is 0.635 cm (0.25 in) thick, with an inner diameter of 5.08 cm (2 in). Based on Monte Carlo model results, when a pre-collimator is present, the use of a neutron absorbing liner on the inside surface of the beam tube has almost no effect on the angular distribution of the neutron current at the collimator exit. The use of a pre-collimator may result in a non-uniform flux profile at the image plane; however, as long as the collimator is at least three times longer than the pre-collimator, the flux distortion is acceptably low.

  13. Two-point method uncertainty during control and measurement of cylindrical element diameters

    NASA Astrophysics Data System (ADS)

    Glukhov, V. I.; Shalay, V. V.; Radev, H.

    2018-04-01

    The topic of the article is devoted to the urgent problem of the reliability of technical products geometric specifications measurements. The purpose of the article is to improve the quality of parts linear sizes control by the two-point measurement method. The article task is to investigate methodical extended uncertainties in measuring cylindrical element linear sizes. The investigation method is a geometric modeling of the element surfaces shape and location deviations in a rectangular coordinate system. The studies were carried out for elements of various service use, taking into account their informativeness, corresponding to the kinematic pairs classes in theoretical mechanics and the number of constrained degrees of freedom in the datum element function. Cylindrical elements with informativity of 4, 2, 1 and θ (zero) were investigated. The uncertainties estimation of in two-point measurements was made by comparing the results of of linear dimensions measurements with the functional diameters maximum and minimum of the element material. Methodical uncertainty is formed when cylindrical elements with maximum informativeness have shape deviations of the cut and the curvature types. Methodical uncertainty is formed by measuring the element average size for all types of shape deviations. The two-point measurement method cannot take into account the location deviations of a dimensional element, so its use for elements with informativeness less than the maximum creates unacceptable methodical uncertainties in measurements of the maximum, minimum and medium linear dimensions. Similar methodical uncertainties also exist in the arbitration control of the linear dimensions of the cylindrical elements by limiting two-point gauges.

  14. Reaction of Titanium and Zirconium Particles in Cylindrical Explosive Charges

    NASA Astrophysics Data System (ADS)

    Frost, David; Cairns, Malcolm; Goroshin, Samuel; Zhang, Fan

    2007-06-01

    The critical conditions for the reaction of high melting-point metallic particles (Ti, Zr) dispersed during the detonation of long cylindrical explosive charges have been investigated experimentally. The charges consisted of packed beds of either spherical titanium particles (with diameters of 35, 90, or 215 μm; AP&C, Inc.) or nonspherical zirconium particles (250 -- 500 μm or 500 -- 600 μm, Atlantic Equipment Eng., NJ) saturated with sensitized liquid nitromethane. For the titanium particles, a threshold particle diameter exists, above which self-sustained particle reaction is not observed, although some particle reaction occurs immediately behind the detonation front then rapidly quenches. For the smallest particles, the proportion of the conical particle cloud that reacts increases with charge diameter, suggesting that the reaction initiation is a competition between particle heating and expansion cooling of the products. For zirconium particles, no critical conditions exist; particle ignition was observed for all particle and charge diameters tested. In this case, interaction of the high pressure detonation wave with the particles is sufficient to initiate reaction at the particle surface after a delay time (˜ 10's μs), which is much less than the time required for thermal equilibration of the particles.

  15. Sources of scattering in vegetarian and other surfaces and objects

    NASA Technical Reports Server (NTRS)

    Moore, R. K.

    1988-01-01

    The sources of scattering in vegetation and other surfaces and objects were studied. A special radar, SOURCESCAT, that could resolve a cylindrical volume 18 cm in diameter and 11 cm long was built. This system provided the first really fine-resolution measurements of radar backscatter from vegetation. The measurements showed that many of the assumptions used previously in modeling vegetation backscatter were false. Vegetation studied included various field crops, prairie grass, and various trees. Major differences were found in the roles of leaves, branches, stems, and trunks for different species. An artificial tree was studied in the laboratory using the systems. The most significant findings were that the average radar volume scattering coefficient is independent of azimuth, and that slanting of the polarization vector can give useful information not available with ordinary vertical and horizontal polarization. A model for scattering from a single leaf was developed. This model, for the first time, took into account the presence of veins in leaves. The pattern of scatter from a leaf was shown quite different from that for which the veins are ignored. A list of publications and presentations resulting from this project are attached.

  16. Slow dynamics at Re =108 in turbulent Helium flows

    NASA Astrophysics Data System (ADS)

    Burguete, Javier; Roche, Philippe; Rousset, Bernard

    2014-11-01

    The presence of slow dynamics is a recurrent feature of many turbulent flows. This behaviour can be created by instabilities of the mean flow or by other mechanisms. In this work we analyze the behavior of a highly turbulent flow (maximum Reynolds number Re =108 , with a Reynolds based on the Taylor microscale Reλ = 2000). The experimental cell consists on a closed cavity filled with liquid Helium (330 liters) close to the lambda point (between 1.8 and 2.5 K) where two inhomogeneous and strongly turbulent flows collide in a thin region. The cylindrical cavity has a diameter of 78cm and two impellers rotate in opposite directions with rotation frequencies up to 2 Hz. The distance between the propellers is 70 cm. Different experimental runs have been performed, both in the normal and superfluid phases. We have performed velocity measurements using home-made Pitot tubes. Here we would like to present preliminary results on this configuration. The analysis of the data series reveals that below the injection frequencies there are different dynamical regimes with time scales two orders of magnitude below the injection scale. We acknowledge support from the EuHIT network and the SHREK Collaboration.

  17. Design and dosimetry of small animal radiation facilities

    NASA Astrophysics Data System (ADS)

    Rodriguez, Manuel R.

    The aim of this work was to develop an irradiation system for radiobiology studies. We designed a novel image-guided micro-irradiator capable of partial-body zebrafish embryo irradiation. The radiation source is a 50 kV photon beam from a miniature x-ray source (Xoft Inc., CA). The source is inserted in a cylindrical brass collimator, 3 cm in diameter and 3 cm in length. The collimator has a 1 mm-diameter pinhole along the longitudinal axis, which provides a well-focused beam with a sharp penumbra. A photodiode is installed at one exit of the pinhole collimator to monitor the photon dose rate. The source with the collimator is attached under a movable table. A video camera, connected to the computer, is placed above the movable table to record position of the specimens in relation to the pinhole collimator. The captured images are analyzed, and the relative distances between the specimens and the pinhole are calculated. The coordinates are sent to the computer-controlled movable table to accurately position the specimens in the beam. Monte Carlo simulations were performed to characterize dosimetric properties of the system, to determine dosimetric sensitivity, and to help in the design. The image-guidance and high precision of the movable table enable very accurate specimen position. The beam monitoring system provides accurate, fast and easy dose determination. Portability and self-shielding make this system suitable for any radiobiology laboratory. This novel micro-irradiator is appropriate for partial irradiation of zebrafish embryos; however its potential use is much wider like irradiation of cell cultures or other small specimens.

  18. Coupled microstrip line transverse electromagnetic resonator model for high-field magnetic resonance imaging.

    PubMed

    Bogdanov, G; Ludwig, R

    2002-03-01

    The performance modeling of RF resonators at high magnetic fields of 4.7 T and more requires a physical approach that goes beyond conventional lumped circuit concepts. The treatment of voltages and currents as variables in time and space leads to a coupled transmission line model, whereby the electric and magnetic fields are assumed static in planes orthogonal to the length of the resonator, but wave-like along its longitudinal axis. In this work a multiconductor transmission line (MTL) model is developed and successfully applied to analyze a 12-element unloaded and loaded microstrip line transverse electromagnetic (TEM) resonator coil for animal studies. The loading involves a homogeneous cylindrical dielectric insert of variable radius and length. This model formulation is capable of estimating the resonance spectrum, field distributions, and certain types of losses in the coil, while requiring only modest computational resources. The boundary element method is adopted to compute all relevant transmission line parameters needed to set up the transmission line matrices. Both the theoretical basis and its engineering implementation are discussed and the resulting model predictions are placed in context with measurements. A comparison between a conventional lumped circuit model and this distributed formulation is conducted, showing significant departures in the resonance response at higher frequencies. This MTL model is applied to simulate two small-bore animal systems: one of 7.5-cm inner diameter, tuned to 200 MHz (4.7 T for proton imaging), and one of 13.36-cm inner diameter, tuned to both 200 and 300 MHz (7 T). Copyright 2002 Wiley-Liss, Inc.

  19. Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study.

    PubMed

    Dave, M H; Frotzler, A; Spielmann, N; Madjdpour, C; Weiss, M

    2010-10-01

    This study compared the fluid leakage in the new 'tapered' shaped against the classic 'cylindrical' shaped tracheal tube cuffs when placed in different sized tracheas. The 7.5 mm internal diameter (ID) tracheal tube cuffs-Tapered Seal Guard (TSG), Standard Seal Guard (SSG), Hi-Lo, Microcuff, Ruesch, and Portex Profile-were compared in an in vitro apparatus. Vertical artificial tracheas with 16, 20, and 22 mm ID were intubated, 5 ml clear water was applied above the unlubricated tube cuffs, and fluid leakage was measured up to 60 min. Data of tapered vs non-tapered tube cuffs (16 observations) were compared for each tracheal diameter using the Mann-Whitney test. Median (range) fluid leakage (ml) at 60 min was 2.14 (0.05-4.88), 1.14 (0.00-4.84), and 0.13 (0.00-1.32), respectively, for 16, 20, and 22 mm tracheas in the TSG tube studies when compared with 4.58 (0.44-4.88), 2.21 (0.00-4.81), and 0.00 (0.00-4.81) in the SSG tube and 4.54 (1.54-4.82), 0.90 (0.00-4.49), and 4.85 (4.40-4.99) in the Microcuff tube studies. Leakage in all polyvinylchloride (PVC) tube cuffs was almost complete (5 ml) within 5 min (P<0.001). The tapered PU tube cuff was as effective as the cylindrical PU cuffs in smaller tracheal diameters and was more efficient than the cylindrical Microcuff PU tube cuff in larger tracheal diameter in preventing subglottic fluid leakage across the tube cuff tested in this in vitro study. PVC tube cuffs leaked much more and faster than PU cuffs.

  20. The effect of geometry and operation conditions on the performance of a gas-liquid cylindrical cyclone separator with new structure

    NASA Astrophysics Data System (ADS)

    Han, Qing; Zhang, Chi; Xu, Bo; Chen, Jiangping

    2013-07-01

    The hydrodynamic flow behavior, effects of geometry and working conditions of a gas-liquid cylindrical cyclone separator with a new structure are investigated by computational fluid dynamic and experiment. Gas liquid cylindrical cyclone separator is widely used in oil industry, refrigeration system because of its simple structure, high separating efficiency, little maintenance and no moving parts nor internal devices. In this work, a gas liquid cylindrical cyclone separator with new structure used before evaporator in refrigeration system can remove the vapor from the mixture and make evaporator compact by improving its heat exchange efficiency with the lower inlet quality. It also decreases evaporator pressure drop and reduces compressor work. The two pipes are placed symmetrically which makes each of them can be treated as inlet. It means when the fluids flow reverse, the separator performance will not be influence. Four samples with different geometry parameters are tested by experiment with different inlet quality (0.18-0.33), inlet mass flow rate (65-100kg/h). Compared with the experimental data, CFD simulation results show a good agreement. Eulerian multiphase model and Reynolds Stress Turbulence model are applied in the CFD simulation and obtained the inner flow field such as phase path lines, tangential velocity profiles and pressure and volume of fraction distribution contours. The separator body diameter (24, 36, 48mm) and inlet diameter (3.84, 4.8, 5.76mm) decide the maximum tangential velocity which results in the centrifugal force. The tangential velocity profiles are simulated and compared among different models. The higher tangential velocity makes higher quality of gas outlet but high pressure drop at the same time. Decreasing the inlet diameter increases quality of gas outlet pipe and pressure drop. High gas outlet quality is cost at high pressure drop. Increasing of separator diameter makes gas outlet quality increase first and then decrease but the pressure drop decreases all the way. The offset (0, 2.4, 3.6mm) of gas outlet is an insensitive factor which influences the quality and pressure drop little.

  1. A 2D analytical cylindrical gate tunnel FET (CG-TFET) model: impact of shortest tunneling distance

    NASA Astrophysics Data System (ADS)

    Dash, S.; Mishra, G. P.

    2015-09-01

    A 2D analytical tunnel field-effect transistor (FET) potential model with cylindrical gate (CG-TFET) based on the solution of Laplace’s equation is proposed. The band-to-band tunneling (BTBT) current is derived by the help of lateral electric field and the shortest tunneling distance. However, the analysis is extended to obtain the subthreshold swing (SS) and transfer characteristics of the device. The dependency of drain current, SS and transconductance on gate voltage and shortest tunneling distance is discussed. Also, the effect of scaling the gate oxide thickness and the cylindrical body diameter on the electrical parameters of the device is analyzed.

  2. Monolithic integration of fine cylindrical glass microcapillaries on silicon for electrophoretic separation of biomolecules

    PubMed Central

    Cao, Zhen; Ren, Kangning; Wu, Hongkai; Yobas, Levent

    2012-01-01

    We demonstrate monolithic integration of fine cylindrical glass microcapillaries (diameter ∼1 μm) on silicon and evaluate their performance for electrophoretic separation of biomolecules. Such microcapillaries are achieved through thermal reflow of a glass layer on microstructured silicon whereby slender voids are moulded into cylindrical tubes. The process allows self-enclosed microcapillaries with a uniform profile. A simplified method is also described to integrate the microcapillaries with a sample-injection cross without the requirement of glass etching. The 10-mm-long microcapillaries sustain field intensities up to 90 kV/m and limit the temperature excursions due to Joule heating to a few degrees Celsius only. PMID:23874369

  3. Electron Transport and Ion Acceleration in a Low-power Cylindrical Hall Thruster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Smirnov; Y. Raitses; N.J. Fisch

    2004-06-24

    Conventional annular Hall thrusters become inefficient when scaled to low power. Cylindrical Hall thrusters, which have lower surface-to-volume ratio, are therefore more promising for scaling down. They presently exhibit performance comparable with conventional annular Hall thrusters. Electron cross-field transport in a 2.6 cm miniaturized cylindrical Hall thruster (100 W power level) has been studied through the analysis of experimental data and Monte Carlo simulations of electron dynamics in the thruster channel. The numerical model takes into account elastic and inelastic electron collisions with atoms, electron-wall collisions, including secondary electron emission, and Bohm diffusion. We show that in order to explainmore » the observed discharge current, the electron anomalous collision frequency {nu}{sub B} has to be on the order of the Bohm value, {nu}{sub B} {approx} {omega}{sub c}/16. The contribution of electron-wall collisions to cross-field transport is found to be insignificant. The plasma density peak observed at the axis of the 2.6 cm cylindrical Hall thruster is likely to be due to the convergent flux of ions, which are born in the annular part of the channel and accelerated towards the thruster axis.« less

  4. Measurements of Surfactant Squeeze-out Using Magnetically-Levitated Liquid Bridges

    NASA Technical Reports Server (NTRS)

    Rosenblatt, Charles

    2004-01-01

    Liquid bridges: Columns of liquid supported by two solid surfaces. These are generally opposing right circular cylinders in 0g. For a cylindrical bridge of length L and diameter d, in zero g, the maximum slenderness ratio Lambda [L/d] = pi [Rayleigh]. In the presence of gravity the cylindrical shape of an axisymmetric bridge tends to deform. Fluid has a volumetric magnetic susceptibility X. Magnetic levitation has numerous applications in studies of fluids, "soft" and "hard" condensed matter physics, and biophysics

  5. DIFFUSION PUMP

    DOEpatents

    Levenson, L.

    1963-09-01

    A high-vacuum diffusion pump is described, featuring a novel housing geometry for enhancing pumping speed. An upright, cylindrical lower housing portion is surmounted by a concentric, upright, cylindrical upper housing portion of substantially larger diameter; an uppermost nozzle, disposed concentrically within the upper portion, is adapted to eject downwardly a conical sheet of liquid outwardly to impinge upon the uppermost extremity of the interior wall of the lower portion. Preferably this nozzle is mounted upon a pedestal rising coaxially from within the lower portion and projecting up into said upper portion. (AEC)

  6. Axial jet mixing of ethanol in cylindrical containers during weightlessness

    NASA Technical Reports Server (NTRS)

    Aydelott, J. C.

    1979-01-01

    An experimental program was conducted to examine the liquid flow patterns that result from the axial jet mixing of ethanol in 10-centimeter-diameter cylindrical tanks in weightlessness. A convex hemispherically ended tank and two Centaur liquid-hydrogen-tank models were used for the study. Four distinct liquid flow patterns were observed to be a function of the tank geometry, the liquid-jet velocity, the volume of liquid in the tank, and the location of the tube from which the liquid jet exited.

  7. Leakage effect analysis on the performance of a cylindrical adjustable inertance tube

    NASA Astrophysics Data System (ADS)

    Zhou, Wenjie; Pfotenhauer, John M.; Zhi, Xiaoqin

    2018-04-01

    The inertance tube plays a significant role in improving the performance of the Stirling type pulse tube cryocooler by providing the desired phase angle between the mass flow and pressure wave. The phase angle is highly depended on the inertance tube geometry, such as diameter and length. A cylindrical threaded root device with variable thread depth on the outer screw and inner screw creates an adjustable inertance tube whose diameter and length can be adjusted in the real time. However, due to its geometry imperfectness, the performance of this threaded inertance tube is reduced by the leaks through the roots between the two screws. Its phase angle shift ability is decreased by 30% with the leakage clearance thickness of 15.5 μm according to both the theoretical prediction and the experimental verification.

  8. Composite drill pipe and method for forming same

    DOEpatents

    Leslie, James C; Leslie, II, James C; Heard, James; Truong, Liem; Josephson, Marvin

    2014-04-15

    Metal inner and outer fittings configured, the inner fitting configured proximally with an external flange and projecting distally to form a cylindrical barrel and stepped down-in-diameter to form an abutment shoulder and then projecting further distally to form a radially inwardly angled and distally extending tapered inner sleeve. An outer sleeve defining a torque tube is configured with a cylindrical collar to fit over the barrel and is formed to be stepped up in diameter in alignment with the first abutment shoulder to then project distally forming a radially outwardly tapered and distally extending bonding surface to cooperate with the inner sleeve to cooperate with the inner sleeve in forming a annular diverging bonding cavity to receive the extremity of a composite pipe to abut against the abutment shoulders and to be bonded to the respective bonding surfaces by a bond.

  9. Directed self-assembly of diblock copolymers in cylindrical confinement: effect of underfilling and air-polymer interactions on configurations

    NASA Astrophysics Data System (ADS)

    Carpenter, Corinne L.; Delaney, Kris T.; Laachi, Nabil; Fredrickson, Glenn H.

    2015-03-01

    Directed self-assembly (DSA) of block copolymers has attracted attention for its use as a simple, cost- effective patterning tool for creating vertical interconnect access (VIA) channels in nanoelectronic devices.1, 2 This technique supplements existing lithographic technologies to allow for the creation of high-resolution cylindrical holes whose diameter and placement can be precisely controlled. In this study, we use self-consistent field theory (SCFT) simulations to investigate the equilibrium configurations of under-filled DSA systems with air-polymer interactions. We report on a series of SCFT simulations of our three species (PMMA-b-PS diblock and air) model in cylindrical confinement to explore the role of template diameter, under-fill fraction (i.e. volume fraction of air), air-polymer surface interaction and polymer-side wall/substrate interactions on equilibrium morphologies in an under-filled template with a free top surface. We identify parameters and system configurations where a meniscus appears and explore cases with PMMA-attractive, PS-attractive, and all-neutral walls to understand the effects of wall properties on meniscus geometry and DSA morphology. An important outcome is an understanding of the parameters that control the contact angle of the meniscus with the wall, as it is one of the simplest quantitative measures of the meniscus shape. Ultimately, we seek to identify DSA formulations, templates, and surface treatments with predictable central cylinder diameter and a shallow contact angle, as these factors would facilitate broad process windows and ease of manufacturing.

  10. Evaluation de l'effet structurel de l'impact d'un micrometeorite ou d'un debris orbital sur le bras Canadien 2

    NASA Astrophysics Data System (ADS)

    Lanouette, Anne-Marie

    Space structures are more and more likely to be impacted at hypervelocities, velocities greater than 3km/s, as the number of orbital debris has rapidly grown in the last two decades. These debris are mostly composed of pieces jettisoned from a launcher or a satellite during the deployment of a structure, dead spacecrafts and fragmentation debris. Collision between two debris, generating many smaller new debris, are more likely to happen. Large space debris (diameter over 10cm) are tracked by different space organizations and their position at all time is known. It is however impossible to track the smaller debris while several studies have already demonstrated that they can also cause significant damage to structures. It is now more and more common to add a kind of protection against collisions to the space structures, but the great majority of space structures currently in orbit, as the Canadarm2, are not protected against hypervelocity impacts. Damage caused by such impacts to different space materials such as aluminum, sandwich panels and laminates has already been characterized during different studies since the end of the 1980s while no study, dedicated to the experimental evaluation of the mechanical properties of a space structure after an impact, relevant to the case of the Canadarm2, has been published. It is only possible to find, in the literature, studies determining the residual mechanical properties after an impact at much lower velocities; the energy of impact is generally three orders of magnitude smaller. The Canadarm2, or Space Station Remote Manipulator System (SSRMS), is installed on the International Space Station (ISS) since 2001. It had an initial 10-year lifespan, but it is still very useful today for maintenance operations and to capture and release incoming space capsules. Understanding the effects of an orbital debris impact on the Canadarm2 structure is now primordial in order to adequately redefine the load levels that can be applied on the arm as a function of the observable damage on the thermal blankets. The main objectives of this study are: first, to obtain a correlation between the visible damage on the booms and the corresponding internal damage of the structure, second to study the cracks caused by the impact growth under different cyclic loads, and finally to provide considerations on the load levels to be applied on the robotic arm as a function of the observable damage. To achieve these objectives, samples representative of the Canadarm2 structure, four cylindrical samples of carbon fibers IM7/PEEK with an external diameter of 35cm and a thickness of 2.7mm, were obtained and covered by pieces of thermal blankets also representative of the Canadarm2. These four samples were impacted at the University of New Brunswick hypervelocity facility, HIT Dynamics. Two samples were impacted by projectiles 5.556mm in diameter and the two remaining samples were impacted with 7.938mm in diameter projectiles. All projectiles were aluminum spheres travelling at ˜7km/s. The samples underwent ultrasonic scanning thereafter to obtain images of their internal damage. In the case of the 5.556mm diameter projectiles, the damage left on the front side was an entry crater 6.2cm in diameter on the thermal blanket and a crater 14.8mm in diameter on the composite wall accompanied by no visual damage on the opposite side of the cylinder. In the case of the 7.938mm diameter projectiles, the damage left on the front side was an entry crater 9.2cm in diameter on the thermal blanket and a crater 17.0mm in diameter on the composite wall accompanied by visible damage on the opposite side in a zone 25.5cm in diameter. The suggestions given for the utilization of the Canadarm2 after an impact are thus the followings. If a crater ≤ 14mm on the composite wall is visible on one side accompanied by no damage on the opposite side of the structure, then the flight and emergency load levels can be maintained. However, if a crater ≤ 17.0mm on the composite wall is visible on one side accompanied by damage in a zone ≤ 25.5cm on the opposite side of the cylinder, only the flight load level can still be used for any position of the damaged zones. If the emergency level must be used, then the damaged zones must absolutely be positioned close to the bending neutral plan, otherwise the applied loads will aggravate the damage caused by the orbital debris impact. (Abstract shortened by ProQuest.).

  11. The conical stent in coronary artery improves hemodynamics compared with the traditional cylindrical stent.

    PubMed

    Yu, Yi; Zhou, Yujie; Ma, Qian; Jia, Shuo; Wu, Sijing; Sun, Yan; Liu, Xiaoli; Zhao, Yingxin; Liu, Yuyang; Shi, Dongmei

    2017-01-15

    This study sought to explore the efficacy of the conical stent implantation in the coronary artery by comparing the effects of cylindrical and conical stents on wall shear stress (WSS) and velocity of flow and fractional flow reserve (FFR). The traditional cylindrical stent currently used in the percutaneous coronary intervention (PCI) has a consistent diameter, which does not match the physiological change of the coronary artery. On the contrary, as a new patent, the conical stent with tapering lumen is consistent with the physiological change of vascular diameter. However, the effect of the conical stent implantation on the coronary hemodynamics remains unclear. The coronary artery, artery stenosis and two stent models were established by Solidworks software. All models were imported into the computational fluid dynamics (CFD) software ANSYS ICEM-CFD to establish the fluid model. After the boundary conditions were set, CFD analysis was proceeded to compare the effects of two stent implantation on the change of WSS, velocity of flow and FFR. Hemodynamic indexes including FFR, blood flow velocity distribution (BVD) and WSS were improved by either the cylindrical or the conical stent implantation. However, after the conical stent implantation, the change of FFR seemed to be slower and more homogenous; the blood flow velocity was more appropriate without any obvious blood stagnation and direction changes; the WSS after the conical stent implantation was uniform from the proximal to distal side of the stent. Compared with the cylindrical stent, the conical stent implantation in the coronary artery can make the changes of vascular hemodynamic more closer to the physiological condition, which can reduce the incidence of intra-stent restenosis and thrombosis, thus making it more suitable for PCI therapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. SU-F-J-08: Quantitative SPECT Imaging of Ra-223 in a Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yue, J; Hobbs, R; Sgouros, G

    Purpose: Ra-223 therapy of prostate cancer bone metastases is being used to treat patients routinely. However, the absorbed dose distribution at the macroscopic and microscopic scales remains elusive, due to the inability to image the small activities injected. Accurate activity quantification through imaging is essential to calculate the absorbed dose in organs and sub-units in radiopharmaceutical therapy, enabling personalized absorbed dose-based treatment planning methodologies and more effective and optimal treatments. Methods: A 22 cm diameter by 20 cm long cylindrical phantom, containing a 3.52 cm diameter sphere, was used. A total of 2.01 MBq of Ra-223 was placed in themore » phantom with 177.6 kBq in the sphere. Images were acquired on a dual-head Siemens Symbia T16 gamma camera using three 20% full-width energy windows and centered at 84, 154, and 269 keV (120 projections, 360° rotation, 45 s per view). We have implemented reconstruction of Ra-223 SPECT projections using OS-EM (up to 20 iterations of 10 subsets) with compensation for attenuation using CT-based attenuation maps, collimator-detector response (CDR) (including septal penetration, scatter and Pb x-ray modeling), and scatter in the patient using the effective source scatter estimation (ESSE) method. The CDR functions and scatter kernels required for ESSE were computed using the SIMIND MC simulation code. All Ra-223 photon emissions as well as gamma rays from the daughters Rn-219 and Bi-211 were modeled. Results: The sensitivity of the camera in the three combined windows was 107.3 cps/MBq. The visual quality of the SPECT images was reasonably good and the activity in the sphere was 27% smaller than the true activity. This underestimation is likely due to partial volume effect. Conclusion: Absolute quantitative Ra-223 SPECT imaging is achievable with careful attention to compensate for image degrading factors and system calibration.« less

  13. New Laboratory Technique to Determine Thermal Conductivity of Complex Regolith Simulants Under High Vacuum

    NASA Astrophysics Data System (ADS)

    Ryan, A. J.; Christensen, P. R.

    2016-12-01

    Laboratory measurements have been necessary to interpret thermal data of planetary surfaces for decades. We present a novel radiometric laboratory method to determine temperature-dependent thermal conductivity of complex regolith simulants under high vacuum and across a wide range of temperatures. Here, we present our laboratory method, strategy, and initial results. This method relies on radiometric temperature measurements instead of contact measurements, eliminating the need to disturb the sample with thermal probes. We intend to determine the conductivity of grains that are up to 2 cm in diameter and to parameterize the effects of angularity, sorting, layering, composition, and cementation. These results will support the efforts of the OSIRIS-REx team in selecting a site on asteroid Bennu that is safe and meets grain size requirements for sampling. Our system consists of a cryostat vacuum chamber with an internal liquid nitrogen dewar. A granular sample is contained in a cylindrical cup that is 4 cm in diameter and 1 to 6 cm deep. The surface of the sample is exposed to vacuum and is surrounded by a black liquid nitrogen cold shroud. Once the system has equilibrated at 80 K, the base of the sample cup is rapidly heated to 450 K. An infrared camera observes the sample from above to monitor its temperature change over time. We have built a time-dependent finite element model of the experiment in COMSOL Multiphysics. Boundary temperature conditions and all known material properties (including surface emissivities) are included to replicate the experiment as closely as possible. The Optimization module in COMSOL is specifically designed for parameter estimation. Sample thermal conductivity is assumed to be a quadratic or cubic polynomial function of temperature. We thus use gradient-based optimization methods in COMSOL to vary the polynomial coefficients in an effort to reduce the least squares error between the measured and modeled sample surface temperature.

  14. Shock interaction behind a pair of cylindrical obstacles

    NASA Astrophysics Data System (ADS)

    Liu, Heng; Mazumdar, Raoul; Eliasson, Veronica

    2014-11-01

    The body of work focuses on two-dimensional numerical simulations of shock interaction with a pair of cylindrical obstacles, varying the obstacle separation and incident shock strength. With the shock waves propagating parallel to the center-line between the two cylindrical obstacles, the shock strengths simulated vary from a Mach of 1.4 to a Mach of 2.4, against a wide range of obstacle separation distance to their diameters. These cases are simulated via a software package called Overture, which is used to solve the inviscid Euler equations of gas dynamics on overlapping grids with adaptive mesh refinement. The goal of these cases is to find a so-called ``safe'' region for obstacle spacing and varying shock Mach numbers, such that the pressure in the ``safe'' region is reduced downstream of the obstacles. The benefits apply to both building and armor design for the purpose of shock wave mitigation to keep humans and equipment safe. The results obtained from the simulations confirm that the length of the ``safe'' region and the degree of shock wave attenuation depend on the ratio of obstacle separation distance to obstacle diameter. The influence of various Mach number is also discussed.

  15. Microstructure and properties of aluminium-aluminium oxide graded composite materials

    NASA Astrophysics Data System (ADS)

    Kamaruzaman, F. F.; Nuruzzaman, D. M.; Ismail, N. M.; Hamedon, Z.; Iqbal, A. K. M. A.; Azhari, A.

    2018-03-01

    In this research works, four-layered aluminium-aluminium oxide (Al-Al2O3) graded composite materials were fabricated using powder metallurgy (PM) method. In processing, metal-ceramic graded composite materials of 0%, 10%, 20% and 30% weight percentage of ceramic concentration were prepared under 30 ton compaction load using a cylindrical die-punch set made of steel. After that, two-step pressureless sintering was carried out at sintering temperature and time 600°C and 3 hours respectively. It was observed that the sintered cylindrical specimens of 30 mm diameter were prepared successfully. The graded composite specimens were analysed and the properties such as density, microstructure and hardness were measured. It was found that after sintering process, the diameter of the graded cylindrical structure was decreased. Using both Archimedes method and rule of mixture (ROM), he density of structure was measured. The obtained results revealed that the microvickers hardness was increased as the ceramic component increases in the graded layer. Moreover, it was observed that the interface of the graded structure is clearly distinguished within the multilayer stack and the ceramic particles are almost uniformly distributed in the Al matrix.

  16. Numerical approach to describe complementary drying of banana slices osmotically dehydrated

    NASA Astrophysics Data System (ADS)

    da Silva Júnior, Aluízio Freire; da Silva, Wilton Pereira; de Farias Aires, Juarez Everton; Farias Aires, Kalina Lígia C. A.

    2018-02-01

    In this work, diffusion model was used to describe the water loss in the complementary drying process of cylindrical slices of banana pretreated by osmotic dehydration. A numerical solution has been proposed for the diffusion equation in cylindrical coordinates, which was obtained through the Finite Volume Method. The diffusion equation was discretized assuming that the effective water diffusivity and the dimensions of a finite cylinder may vary; also considering the boundary condition of the third kind. The banana slices were cut in length of about 1.00 cm and average radius 1.70 cm before osmotic pretreatment, and completed the pretreatment with length of about 0.74 cm and average radius 1.40 cm. The complementary drying was carried out in a kiln with circulation and air exchange. Drying temperatures were the same as used in the osmotic pretreatment (40 to 70 °C). The proposed model described well the water loss, with good statistical indicators for all fits.

  17. SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, H; Lee, Y; Pokhrel, D

    2015-06-15

    Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm)more » using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.« less

  18. Improved ceramic heat exchanger material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rauch, H.W. Sr.

    Various ceramic materials in the form of small, monolithic bars were screened as candidate materials in heat exchanger structures for automotive gas turbine engines. The material finally selected consists of 60 w/o* petalite (LAS) and 40 w/o of a recrystallizable glass which converts during thermal processing to cordierite (MAS). This new material, GE-3200, was fabricated by Coors Porcelain Company into a circular honeycomb structure 53.3 cm diameter and 10.2 cm thick (21'' x 4'') and having 69.8 holes/cm/sup 2/ (450 holes/in./sup 2/) of rectangular geometry. Dimensions of each cell are about 2.5 mm x 0.5 mm (0.1'' x 0.02'') withmore » wall thicknesses about 0.20 mm (0.008''). Small bar-shaped specimens of the honeycomb were used to measure thermal, chemical, and mechanical properties and for macro- and microstructure examination. Cylindrical honeycomb specimens about 15.2 cm diameter and 10.2 in. thick (6'' x 4'') were sent to Ford Motor Company and are currently being tested in a gas turbine engine. Data obtained from testing the bar-shaped honeycomb specimens of GE-3200 and from testing bar-shaped honeycomb specimens of Corning 9455 were compared. Results indicate that GE-3200 has significantly better resistance to sulfuric acid and to sodium chloride than Corning 9455; thermal expansion of GE-3200 is higher than that of Corning 9455 (1.7 x 10/sup -6///sup 0/C vs. 0.65 x 10/sup -6///sup 0/C over the temperature range 25/sup 0/C to 1000/sup 0/C); mechanical properties of GE-3200 are higher in the tangential direction, but lower in the radial direction than Corning 9455; and during thermal cycling between R.T. 1000/sup 0/C and R.T. -1100/sup 0/C, GE-3200 tends to elongate while Corning 9455 tends to slightly contract. Overall assessment of GE-3200 properties, ease of material preparation, ready adaptability to honeycomb fabrication, and refractoriness qualify this new material as a candidate for heat exchanger application in automotive gas turbine engines.« less

  19. Monolithic Cylindrical Fused Silica Resonators with High Q Factors

    PubMed Central

    Pan, Yao; Wang, Dongya; Wang, Yanyan; Liu, Jianping; Wu, Suyong; Qu, Tianliang; Yang, Kaiyong; Luo, Hui

    2016-01-01

    The cylindrical resonator gyroscope (CRG) is a typical Coriolis vibratory gyroscope whose performance is determined by the Q factor and frequency mismatch of the cylindrical resonator. Enhancing the Q factor is crucial for improving the rate sensitivity and noise performance of the CRG. In this paper, for the first time, a monolithic cylindrical fused silica resonator with a Q factor approaching 8 × 105 (ring-down time over 1 min) is reported. The resonator is made of fused silica with low internal friction and high isotropy, with a diameter of 25 mm and a center frequency of 3974.35 Hz. The structure of the resonator is first briefly introduced, and then the experimental non-contact characterization method is presented. In addition, the post-fabrication experimental procedure of Q factor improvement, including chemical and thermal treatment, is demonstrated. The Q factor improvement by both treatments is compared and the primary loss mechanism is analyzed. To the best of our knowledge, the work presented in this paper represents the highest reported Q factor for a cylindrical resonator. The proposed monolithic cylindrical fused silica resonator may enable high performance inertial sensing with standard manufacturing process and simple post-fabrication treatment. PMID:27483263

  20. Dependence of Initial Oxygen Concentration on Ozone Yield Using Inductive Energy Storage System Pulsed Power Generator

    NASA Astrophysics Data System (ADS)

    Go, Tomio; Tanaka, Yasushi; Yamazaki, Nobuyuki; Mukaigawa, Seiji; Takaki, Koichi; Fujiwara, Tamiya

    Dependence of initial oxygen concentration on ozone yield using streamer discharge reactor driven by an inductive energy storage system pulsed power generator is described in this paper. Fast recovery type diodes were employed as semiconductor opening switch to interrupt a circuit current within 100 ns. This rapid current change produced high-voltage short pulse between a secondary energy storage inductor. The repetitive high-voltage short pulse was applied to a 1 mm diameter center wire electrode placed in a cylindrical pulse corona reactor. The streamer discharge successfully occurred between the center wire electrode and an outer cylinder ground electrode of 2 cm inner diameter. The ozone was produced with the streamer discharge and increased with increasing pulse repetition rate. The ozone yield changed in proportion to initial oxygen concentration contained in the injected gas mixture at 800 ns forward pumping time of the current. However, the decrease of the ozone yield by decreasing oxygen concentration in the gas mixture at 180 ns forward pumping time of the current was lower than the decrease at 800 ns forward pumping time of the current. This dependence of the initial oxygen concentration on ozone yield at 180 ns forward pumping time is similar to that of dielectric barrier discharge reactor.

  1. Longitudinally Controlled Modification of Cylindrical and Conical Track-Etched Poly(ethylene terephthalate) Pores Using an Electrochemically Assisted Click Reaction

    DOE PAGES

    Coceancigh, Herman; Tran-Ba, Khanh-Hoa; Siepser, Natasha; ...

    2017-09-27

    Here in this study, the longitudinally controlled modification of the inner surfaces of poly(ethylene terephthalate) (PET) track-etched pores was explored using an electrochemically assisted Cu(I)-catalyzed azide–alkyne cycloaddition (CuAAC) click reaction. Cylindrical or conical PET track-etched pores were first decorated with ethynyl groups via the amidation of surface -COOH groups, filled with a solution containing Cu(II) and azide-tagged fluorescent dye, and then sandwiched between comb-shaped and planar gold electrodes. Cu(I) was produced at the comb-shaped working electrode by the reduction of Cu(II); it diffused along the pores toward the other electrode and catalyzed CuAAC between an azide-tagged fluorescent dye and amore » pore-tethered ethynyl group. The modification efficiency of cylindrical pores (ca. 1 μm in diameter) was assessed from planar and cross-sectional fluorescence microscope images of modified membranes. Planar images showed that pore modification took place only above the teeth of the comb-shaped electrode with a higher reaction yield for longer Cu(II) reduction times. Cross-sectional images revealed micrometer-scale gradient modification along the pore axis, which reflected a Cu(I) concentration profile within the pores, as supported by finite-element computer simulations. The reported approach was applicable to the asymmetric modification of cylindrical pores with two different fluorescent dyes in the opposite directions and also for the selective visualization of the tip and base openings of conical pores (ca. 3.5 μm in base diameter and ca. 1 μm in tip diameter). Lastly, the method based on electrochemically assisted CuAAC provides a controlled means to fabricate asymmetrically modified nanoporous membranes and, in the future, will be applicable for chemical separations and the development of sequential catalytic reactors.« less

  2. Longitudinally Controlled Modification of Cylindrical and Conical Track-Etched Poly(ethylene terephthalate) Pores Using an Electrochemically Assisted Click Reaction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coceancigh, Herman; Tran-Ba, Khanh-Hoa; Siepser, Natasha

    Here in this study, the longitudinally controlled modification of the inner surfaces of poly(ethylene terephthalate) (PET) track-etched pores was explored using an electrochemically assisted Cu(I)-catalyzed azide–alkyne cycloaddition (CuAAC) click reaction. Cylindrical or conical PET track-etched pores were first decorated with ethynyl groups via the amidation of surface -COOH groups, filled with a solution containing Cu(II) and azide-tagged fluorescent dye, and then sandwiched between comb-shaped and planar gold electrodes. Cu(I) was produced at the comb-shaped working electrode by the reduction of Cu(II); it diffused along the pores toward the other electrode and catalyzed CuAAC between an azide-tagged fluorescent dye and amore » pore-tethered ethynyl group. The modification efficiency of cylindrical pores (ca. 1 μm in diameter) was assessed from planar and cross-sectional fluorescence microscope images of modified membranes. Planar images showed that pore modification took place only above the teeth of the comb-shaped electrode with a higher reaction yield for longer Cu(II) reduction times. Cross-sectional images revealed micrometer-scale gradient modification along the pore axis, which reflected a Cu(I) concentration profile within the pores, as supported by finite-element computer simulations. The reported approach was applicable to the asymmetric modification of cylindrical pores with two different fluorescent dyes in the opposite directions and also for the selective visualization of the tip and base openings of conical pores (ca. 3.5 μm in base diameter and ca. 1 μm in tip diameter). Lastly, the method based on electrochemically assisted CuAAC provides a controlled means to fabricate asymmetrically modified nanoporous membranes and, in the future, will be applicable for chemical separations and the development of sequential catalytic reactors.« less

  3. Heat Transfer to 36.75 and 45 degree Swept Blunt Leading Edges in Free Flight at Mach Numbers from 1.70 to 2.99 and From 2.50 to 4.05

    NASA Technical Reports Server (NTRS)

    ONeal, Robert L.

    1960-01-01

    A flight investigation has been conducted to study the heat transfer to swept-wing leading edges. A rocket-powered model was used for the investigation and provided data for Mach number ranges of 1.78 to 2.99 and 2.50 to 4.05 with corresponding free-stream Reynolds number per foot ranges of 13.32 x 10(exp 6) to 19.90 x 10(exp 6) and 2.85 x 10(exp 6) to 4.55 x 10(exp 6). The leading edges employed were cylindrically blunted wedges ', three of which were swept 450 with leading-edge diameters of 1/4, 1/2, and 3/4 inch and one swept 36-750 with a leading-edge diameter of 1/2 inch. In the high Reynolds number range, measured values of heat transfer were found to be much higher than those predicted by laminar theory and at the larger values of leading-edge diameter were approaching the values predicted by turbulent theory. For the low Reynolds number range a comparison between measured and theoretical heat transfer showed that increasing the leading-edge diameter resulted in turbulent flow on the cylindrical portion of the leading edge.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, J; Sarwan, R; Pavord, D

    Purpose: To quantitatively compare low dose spillage outside of PTV edge in arc therapy modalities Methods: The machines used in the study are Tomotherapy Hi-Arc and Varian 21EX with millennium120 MLC. TPS are TomoPlaning and RayStation for VMAT, respectively. The phantom is a 30cm diameter cylindrical solid water (TOMOTHERAPY, TOMOPHANTOM ASSY). The PTV is 4cm length with ellipsoidal sectional shape with major axis=5cm, minor axis=3cm in the axial plane and reversed in the coronal plane. The PTV volume is created with interpolation. It is located at the center of the phantom. The prescribed dose is 1000x5 cGy to 95% themore » PTV. The isocenter is set co-centered with the PTV. EBT-3 film was used to measure iso-dose lines at the center plane. Film dosimetry is performed with the RIT, v6.2. Results: the study shows: (1) dose falloff gradient is usually uneven, depending on the PTV shape in the gantry rotation plane. For an elliptical shape, the low dose spillage is wider in the minor axis direction than that in the major axis direction. The more a shape is closer to circular, the more even gradient is all directions; (2)for a circular shape (CAX plane in this study), the maximum dose in % of Rx dose at 2cm from PTV is 55% for Tomo, vs. 70% for VMAT (3) the most rapid dose falloff rang is between 95%–80% IDL for both modalities. Conclusion: Tomo has more rapid dose falloff outside of PTV. In some areas, the gradient is double for Tomo helical than that for LINAC VMAT at same points. Future work will examine the differences between optimization of doses and inherent delivery limitations.« less

  5. Formation of hexagonal boron nitride nanoscrolls induced by inclusion and exclusion of self-assembling molecules in solution process

    NASA Astrophysics Data System (ADS)

    Hwang, Da Young; Suh, Dong Hack

    2014-05-01

    Unlike nanoscrolls of 2D graphene, those of 2D h-BN have not been demonstrated, except for only a few experimental reports. Nanoscrolls of h-BN with high yields and reproducibility are first synthesized by a simple solution process. Inner-tube diameters of BNSs including LCAs, N-(2-aminoethyl)-3α-hydroxy-5β-cholan-24-amide, a bile acid derivative and self-assembling material, can be controlled by adjusting the diameter of the LCA fiber which is grown by self-assembly. TEM and SEM images show that BNSs have a tube-like morphology and the inner-tube diameter of BNSs can be controlled in the range from 20 to 60 nm for a smaller diameter, up to 300 nm for a larger diameter by LCA fiber growth inside the BNSs. Finally, open cylindrical BNSs with hollow cores were obtained by dissolving LCAs inside BNSs.Unlike nanoscrolls of 2D graphene, those of 2D h-BN have not been demonstrated, except for only a few experimental reports. Nanoscrolls of h-BN with high yields and reproducibility are first synthesized by a simple solution process. Inner-tube diameters of BNSs including LCAs, N-(2-aminoethyl)-3α-hydroxy-5β-cholan-24-amide, a bile acid derivative and self-assembling material, can be controlled by adjusting the diameter of the LCA fiber which is grown by self-assembly. TEM and SEM images show that BNSs have a tube-like morphology and the inner-tube diameter of BNSs can be controlled in the range from 20 to 60 nm for a smaller diameter, up to 300 nm for a larger diameter by LCA fiber growth inside the BNSs. Finally, open cylindrical BNSs with hollow cores were obtained by dissolving LCAs inside BNSs. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr00897a

  6. Performance of large area xenon ion thrusters for orbit transfer missions

    NASA Technical Reports Server (NTRS)

    Rawlin, Vincent K.

    1989-01-01

    Studies have indicated that xenon ion propulsion systems can enable the use of smaller Earth-launch vehicles for satellite placement which results in significant cost savings. These analyses have assumed the availability of advanced, high power ion thrusters operating at about 10 kW or higher. A program was initiated to explore the viability of operating 50 cm diameter ion thrusters at this power level. Operation with several discharge chamber and ion extraction grid set combinations has been demonstrated and data were obtained at power levels to 16 kW. Fifty cm diameter thrusters using state of the art 30 cm diameter grids or advanced technology 50 cm diameter grids allow discharge power and beam current densities commensurate with long life at power levels up to 10 kW. In addition, 50 cm diameter thrusters are shown to have the potential for growth in thrust and power levels beyond 10 KW.

  7. Evaluation of static resistance of deep foundation [project summary].

    DOT National Transportation Integrated Search

    2017-06-01

    Various types of deep foundations were investigated including steel H-piles, pre-stressed concrete piles, open cylindrical steel and concrete piles with diameters greater than 36 inches, and drilled shafts with partial length permanent casing. : The ...

  8. Development of a miniature double-pass cylindrical mirror electron energy analyzer (DPCMA), and its application to Auger photoelectron coincidence spectroscopy (APECS)

    NASA Astrophysics Data System (ADS)

    Kobayashi, Eiichi; Seo, Junya; Nambu, Akira; Mase, Kazuhiko

    2007-09-01

    We have developed a miniature double-pass cylindrical mirror electron energy analyzer (DPCMA) with an outer diameter of 26 mm. The DPCMA consists of a shield for the electric field, inner and outer cylinders, two pinholes with a diameter of 2.0 mm, and an electron multiplier. By assembling the DPCMA in a coaxially symmetric mirror electron energy analyzer (ASMA) coaxially and confocally we developed an analyzer for Auger photoelectron coincidence spectroscopy (APECS). The performance was estimated by measuring the Si-LVV-Auger Si-1s-photoelectron coincidence spectra of clean Si(1 1 1). The electron-energy resolution of the DPCMA was estimated to be E/Δ E = 20. This value is better than that of the miniature single-pass CMA ( E/Δ E = 12) that was used in the previous APECS analyzer.

  9. Optimization of light dosimetry for photodynamic therapy of Barrett's esophagus

    NASA Astrophysics Data System (ADS)

    Panjehpour, Masoud; Phan, Mary N.; Overholt, Bergein F.; Haydek, John M.

    2004-06-01

    Background and Objective: Photodynamic therapy (PDT) may be used for ablation of high grade dysplasia and/or early cancer (HGD/T1) in Barrett's esophagus. A complication of PDT is esophageal stricture. The objective of this study was to find the lowest light dose to potentially reduce the incidence of strictures while effectively ablating HGD/T1. Materials and Methods: Patients (n=113) with HGD/T1 received an intravenous injection of porfimer sodium (2 mg/kg). Three days later, laser light (630 nm) was delivered using a cylindrical diffuser inserted in a 20 mm.diameter PDT balloon. Patients were treated at light doses of 115 J/cm, 105 J/cm, 95 J/cm and 85 J/cm. The efficacy was determined by four quadrant biopsies of the treated area three months after PDT. The formation of stricture was determined by the incidence of dysphagia and the need for esophageal dilation. Strictures were considered mild if they required less than 6 dilations, and severe if 6 or more dilations were required. Efficacy and incidence of strictures were tabulated as a function of light dose. Results: Using 115 J/cm, there were 17% of patients with residual HGD/T1 after one treatment. However, when the light doses of 105 J/cm, 95 J/cm and 85 J/cm were used, the residual HGD/T1 after one PDT session was increased to 33%, 30%, and 32% respectively. The overall incidence of strictures (mild and severe) was not correlated to the light dose. However, the incidence of severe strictures was directly proportional to the light dose. Using the light dose of 115 J/cm, 15.3% of patients developed severe strictures compared to about 5% in the groups of patients who received the lower light doses. Conclusions: Decreasing the light dose below 115 J/cm doubled the rate of residual HGD/T1 after one treatment while reducing the incidence of severe strictures to one-third of cases from 115 J/cm. The results may be used to evaluate the risks and benefits of different light doses.

  10. Transgressive reef sequences of the Devonian Devils Gate Limestone, Red Hill, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shapiro, R.; Dehler, C.; Flynn, J.

    The Devils Gate Limestone at Red Hill, Simpson Park Range, Eureka Co., Nevada is composed of several conformable transgressive sequences cropping out in a series of step-like cliffs 1--5 m high. The general sequence is as follows: (1) a 1--4 m thick in situ boundstone dominated by large, period rugosans, domical and stratiform stromatoporids and rare, 1--3 cm diameter oncolites. Most of the boundstone is composed of small, cylindrical fossils. Petrographic observation revealed them to be mostly Amphipora and Cladopora. The upper portions of these units are packstones composed of Amphipora/Cladopora and, to a lesser degree, small favositids, round stromatoporoidsmore » (3--4 cm diameter), and rip-up clasts. (2) These beds grade upward into a thinly laminated and/or cross-bedded unfossiliferous mudstone. (3) Stratigraphically above the mudstone or in contact with the packstone, is a cross-bedded and/or bioturbated wackestone containing fossils no greater than 2 mm. In thin section, the mottled reddish-grey wackestone is pelletal, with rare lenses of small crinoid columnals. Disarticulated brachiopod shells of low diversity are found near the tops of some of these layers. Community dominance in the reefal units alternates between Amphipora/Cladopora, colonial rugose, and stromatoporoids. Oncolite mounds are common in the uppermost unit. The typical reef succession consists of domical and digitate stromatoporoids growing on the upper surfaces of in place or disturbed, large rugosans, though the reverse has been noted. Tabulate corals encrusted by stromatoporoids are often found in the packstone. It is important to note that often these successions' can be attributed to juxtaposition along styolites.« less

  11. L-band Dielectric Constant Measurements of Seawater (Oral presentation and SMOS Poster)

    NASA Technical Reports Server (NTRS)

    Lang, Roger H.; Utku, Cuneyt; LeVine, David M.

    2003-01-01

    This paper describes a resonant cavity technique for the measurement of the dielectric constant of seawater as a function of its salinity. Accurate relationships between salinity and dielectric constant (which determines emissivity) are needed for sensor systems such as SMOS and Aquarius that will monitor salinity from space in the near future. The purpose of the new measurements is to establish the dependence of the dielectric constant of seawater on salinity in contemporary units (e.g. psu) and to take advantage of modern instrumentation to increase the accuracy of these measurements. The measurement device is a brass cylindrical cavity 16cm in diameter and 7cm in height. The seawater is introduced into the cavity through a slender glass tube having an inner diameter of 0.1 mm. By assuming that this small amount of seawater slightly perturbs the internal fields in the cavity, perturbation theory can be employed. A simple formula results relating the real part of the dielectric constant to the change in resonant frequency of the cavity. In a similar manner, the imaginary part of the dielectric constant is related to the change in the cavity s Q. The expected accuracy of the cavity technique is better than 1% for the real part and 1 to 2% for the imaginary part. Presently, measurements of methanol have been made and agree with precision measurements in the literature to within 1% in both real and imaginary parts. Measurements have been made of the dielectric constant of seawater samples from Ocean Scientific in the United Kingdom with salinities of 10, 30, 35 and 38 psu. All measurements were made at room temperature. Plans to make measurements at a range of temperatures and salinities will be discussed.

  12. [A parallel-plate small volume chamber for dosimetry of fast electrons and its use].

    PubMed

    Markus, B

    1976-12-01

    The ionization chamber described is designed for dosimetry of electron radiation above ca. 100 keV. It is used for the measurement of the cavity ion dose and of the absorbed dose within solid or water phantoms. Its construction corresponds to a flat chamber in accordance with DIN 6800. The cylindric main body is made of plexiglass (diameter 30 mm, height 14 mm) and encompasses the measuring volume being flush with the surface (diameter 5 mm, height 2 mm; chamber window 2.3 mg/cm2; build up cap for measurements in water 236 mg/cm2). The chamber is constructed with regard to its independency on energy and direction of the incidence as well as to the minimization of the remaining influence quantities, thus answering for the accuracy class "reference-class instrument" (+/- 0.5%). The polarity effect and field perturbation effect are to be neglected, the displacement comes to 0.1 mm, the statistical inaccuracy of measurement to 0.1%. The calibration for the chamber was obtained with a 15 MeV electron beam. The calibration factor for the cavity ion dose is constant, not being related to energy, at least in the range of performance from 2 to 15 MeV according to the primary standard used for calibration (graphic double extrapolation chamber). The overall uncertainty of the calibration factor amounts to +/- 1.5% for the cavity ion dose and to +/- 1.8% for the energy dose. Numerical values of all characteristic quantities and influence quantities which correspond to DIN 6817 and also measurement results for the determination of dose and energy are reported.

  13. A High-Resolution Time-of-Flight Clinical PET Detection System Using a Gapless PMT-Quadrant-Sharing Method

    NASA Astrophysics Data System (ADS)

    Wong, Wai-Hoi; Li, Hongdi; Zhang, Yuxuan; Ramirez, Rocio; An, Shaohui; Wang, Chao; Liu, Shitao; Dong, Yun; Baghaei, Hossain

    2015-10-01

    We developed a high-resolution Photomultiplier-Quadrant-Sharing (PQS) PET system for human imaging. This system is made up of 24 detector panels. Each panel (bank) consists of 3 ×7 detector blocks, and each block has 16 ×16 LYSO crystals of 2.35 ×2.35 ×15.2 mm3. We used a novel detector-grinding scheme that is compatible with the PQS detector-pixel-decoding requirements to make a gapless cylindrical detector ring for maximizing detection efficiency while delivering an ultrahigh spatial-resolution for a whole-body PET camera with a ring diameter of 87 cm and axial field of view of 27.6 cm. This grinding scheme enables two adjacent gapless panels to share one row of the PMTs to extend the PQS configuration beyond one panel and thus maximize the economic benefit (in PMT usage) of the PQS design. The entire detector ring has 129,024 crystals, all of which are clearly decoded using only 576 PMTs (38-mm diameter). Thus, each PMT on average decodes 224 crystals to achieve a high crystal-pitch resolution of 2.44 mm ×2.44 mm. The detector blocks were mass-produced with our slab-sandwich-slice technique using a set of optimized mirror-film patterns (between crystals) to maximize light output and achieve high spatial and timing resolution. This detection system with time-of-flight capability was placed in a human PET/CT gantry. The reconstructed image resolution of the system was about 2.87 mm using 2D-filtered back-projection. The time-of-flight resolution was 473 ps. The preliminary images of phantoms and clinical studies presented in this work demonstrate the capability of this new PET/CT system to produce high-quality images.

  14. Thermodynamic, Transport and Chemical Properties of Reference JP-8

    DTIC Science & Technology

    2006-06-01

    external diameter, 0.18 cm internal diameter) that are sealed on one end with a stainless steel plug welded by a clean tungsten-inert-gas ( TIG ) 15...tubing with an internal diameter of 0.02 cm, also TIG welded to the cell. Each cell and valve is capable of withstanding a pressure in excess of 105... process . Each cell is connected to a high-pressure high-temperature valve at the other end with a short length of 0.16 cm diameter 316 stainless steel

  15. Ant-nest ichnofossils in honeycomb calcretes, Neogene Ogallala Formation, High Plains region of western Kansas, U.S.A.

    USGS Publications Warehouse

    Smith, J.J.; Platt, B.F.; Ludvigson, Greg A.; Thomasson, J.R.

    2011-01-01

    Two new ant-nest trace fossils are described from calcic sandy paleosols of the Neogene Ogallala Formation in western Kansas. The ichnofossils are preserved within and below calcrete beds weathering in positive relief as carbonate-filled casts or as cavities in negative relief. Daimoniobarax ichnogenus nov. is established for burrow systems composed of vertically tiered, horizontally oriented pancake-shaped chambers connected by predominantly vertical and cylindrical shafts ~. 0.8. cm in diameter. Ichnospecies of Daimoniobarax are differentiated based on differences in the plan view outline of chambers, shaft orientation, and junctions between chambers and shafts.Daimoniobarax nephroides ichnospecies nov. is composed of an ~. 24-76. cm long vertical sequence of distinctly lobed chambers (~. 2-20. cm wide and ~. 1. cm high) arranged along sinuous to helical shafts. Chamber shape in plan view ranges from small teardrops to larger kidney- and U-shaped forms. Shafts intersect at chamber edges such that chambers appear to bud from the central shafts. Daimoniobarax nephroides is most similar to the nests of extant seed-harvester ants of the New World genus Pogonomyrmex. Such ants are specialized granivores and prefer sandy soils in arid to semi-arid grassland and desert regions.Daimoniobarax tschinkeli ichnospecies nov. is ~. 30-80. cm in vertical extent. Chambers (~. 2-30. cm wide and ~. 1. cm high) are circular to elongate or pseudopodial in plan view. Vertical shafts are straight to slightly sinuous and intersect most often toward the center of the chambers. The generalized architecture of D. tschinkeli is similar to that of the nests or nest portions of several extant ant genera, though it does not closely resemble any known modern nest.Ant ichnofossils provide valuable information on hidden biodiversity, paleohydrologic regimes, paleopedogenic processes, and paleoclimate during the time of nest occupation. Depth-related changes in chamber size and vertical spacing may also help interpret paleosurfaces and paleodepths, and serve as geopetal features. ?? 2011 Elsevier B.V.

  16. Size Effect and Cylinder test on Several Commercial Explosives

    NASA Astrophysics Data System (ADS)

    Lauderbach, Lisa; Moua, Kou; Garza, Raul; Souers, Clark

    2011-06-01

    The size (diameter) effect and the Cylinder test results for ammonium nitrate/nitromethane, some ammonium nitrate/fuel oil mixes, Red Dot shotgun powder, Semtex 1A and Semtex H will be presented. A generalized detonation velocity format, valid for all detonation rates, will be discussed. A shot in cylindrical symmetry will be compared with the 1-D cylindrical size effect data. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  17. Water-mediated interactions between hydrophobic and ionic species in cylindrical nanopores

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vaitheeswaran, S.; Reddy, G.; Thirumalai, D.

    2009-03-07

    We use Metropolis Monte Carlo and umbrella sampling to calculate the free energies of interaction of two methane molecules and their charged derivatives in cylindrical water-filled pores. Confinement strongly alters the interactions between the nonpolar solutes and completely eliminates the solvent separated minimum (SSM) that is seen in bulk water. The free energy profiles show that the methane molecules are either in contact or at separations corresponding to the diameter and the length of the cylindrical pore. Analytic calculations that estimate the entropy of the solutes, which are solvated at the pore surface, qualitatively explain the shape of the freemore » energy profiles. Adding charges of opposite sign and magnitude 0.4e or e (where e is the electronic charge) to the methane molecules decreases their tendency for surface solvation and restores the SSM. We show that confinement induced ion-pair formation occurs whenever l{sub B}/D{approx}O(1), where l{sub B} is the Bjerrum length and D is the pore diameter. The extent of stabilization of the SSM increases with ion charge density as long as l{sub B}/D<1. In pores with D{<=}1.2 nm, in which the water is strongly layered, increasing the charge magnitude from 0.4e to e reduces the stability of the SSM. As a result, ion-pair formation that occurs with negligible probability in the bulk is promoted. In larger diameter pores that can accommodate a complete hydration layer around the solutes, the stability of the SSM is enhanced.« less

  18. Effect of rotor configuration on guyed tower and foundation designs and estimated costs for intermediate site horizontal axis wind turbines

    NASA Technical Reports Server (NTRS)

    Frederick, G. R.; Winemiller, J. R.; Savino, J. M.

    1982-01-01

    Three designs of a guyed cylindrical tower and its foundation for an intermediate size horizontal axis wind turbine generator are discussed. The primary difference in the three designs is the configuration of the rotor. Two configurations are two-blade rotors with teetering hubs - one with full span pitchable blades, the other with fixed pitch blades. The third configuration is a three-bladed rotor with a rigid hub and fixed pitch blades. In all configurations the diameter of the rotor is 38 meters and the axis of rotation is 30.4 meters above grade, and the power output is 200 kW and 400 kW. For each configuration the design is based upon for the most severe loading condition either operating wind or hurricane conditions. The diameter of the tower is selected to be 1.5 meters (since it was determined that this would provide sufficient space for access ladders within the tower) with guy rods attached at 10.7 meters above grade. Completing a design requires selecting the required thicknesses of the various cylindrical segments, the number and diameter of the guy rods, the number and size of soil anchors, and the size of the central foundation. The lower natural frequencies of vibration are determined for each design to ensure that operation near resonance does not occur. Finally, a cost estimate is prepared for each design. A preliminary design and cost estimate of a cantilever tower (cylindrical and not guyed) and its foundation is also presented for each of the three configurations.

  19. Polyelectrolyte layer-by-layer deposition in cylindrical nanopores.

    PubMed

    Lazzara, Thomas D; Lau, K H Aaron; Abou-Kandil, Ahmed I; Caminade, Anne-Marie; Majoral, Jean-Pierre; Knoll, Wolfgang

    2010-07-27

    Layer-by-layer (LbL) deposition of polyelectrolytes within nanopores in terms of the pore size and the ionic strength was experimentally studied. Anodic aluminum oxide (AAO) membranes, which have aligned, cylindrical, nonintersecting pores, were used as a model nanoporous system. Furthermore, the AAO membranes were also employed as planar optical waveguides to enable in situ monitoring of the LbL process within the nanopores by optical waveguide spectroscopy (OWS). Structurally well-defined N,N-disubstituted hydrazine phosphorus-containing dendrimers of the fourth generation, with peripherally charged groups and diameters of approximately 7 nm, were used as the model polyelectrolytes. The pore diameter of the AAO was varied between 30-116 nm and the ionic strength was varied over 3 orders of magnitude. The dependence of the deposited layer thickness on ionic strength within the nanopores is found to be significantly stronger than LbL deposition on a planar surface. Furthermore, deposition within the nanopores can become inhibited even if the pore diameter is much larger than the diameter of the G4-polyelectrolyte, or if the screening length is insignificant relative to the dendrimer diameter at high ionic strengths. Our results will aid in the template preparation of polyelectrolyte multilayer nanotubes, and our experimental approach may be useful for investigating theories regarding the partitioning of nano-objects within nanopores where electrostatic interactions are dominant. Furthermore, we show that the enhanced ionic strength dependence of polyelectrolyte transport within the nanopores can be used to selectively deposit a LbL multilayer atop a nanoporous substrate.

  20. Common iliac artery aneurysms in patients with abdominal aortic aneurysms.

    PubMed

    Armon, M P; Wenham, P W; Whitaker, S C; Gregson, R H; Hopkinson, B R

    1998-03-01

    To determine the incidence of common iliac artery (CIA) aneurysms in patients with abdominal aortic aneurysms (AAA) and to evaluate the relationship between AAA and CIA diameter. Spiral CT angiography was used to measure the maximum diameters of the abdominal aorta and the common iliac arteries of 215 patients with AAA. The median CIA diameter was 1.7 cm--significantly greater than the published mean of 1.25 (2 S.D. = 0.85-1.65) cm of an age-matched, non-vascular population. Thirty-four patients (16%) had unilateral and 26 patients (12%) bilateral CIA aneurysms > or = 2.4 cm diameter. Eight-six vessels (20%) were affected. Right CIA diameters were wider than left CIA diameters (p < 0.0001, Wilcoxon matched-pairs signed rank test). The correlation between AAA size and CIA diameter was weak. The AAA population has abnormally dilated common iliac arteries. In this population, common iliac artery aneurysms should be defined as those greater than 2.4 cm diameter. 20% of CIAs in patients with AAA are aneurysmal according to this definition.

  1. Investigation of plasma parameters at BATMAN for variation of the Cs evaporation asymmetry and comparing two driver geometries

    NASA Astrophysics Data System (ADS)

    Wimmer, C.; Fantz, U.; Aza, E.; Jovović, J.; Kraus, W.; Mimo, A.; Schiesko, L.

    2017-08-01

    The Neutral Beam Injection (NBI) system for fusion devices like ITER and, beyond ITER, DEMO requires large scale sources for negative hydrogen ions. BATMAN (Bavarian Test Machine for Negative ions) is a test facility attached with the prototype source for the ITER NBI (1/8 source size of the ITER source), dedicated to physical investigations due to its flexible access for diagnostics and exchange of source components. The required amount of negative ions is produced by surface conversion of hydrogen atoms or ions on caesiated surfaces. Several diagnostic tools (Optical Emission Spectroscopy, Cavity Ring-Down Spectroscopy for H-, Langmuir probes, Tunable Diode Laser Absorption Spectroscopy for Cs) allow the determination of plasma parameters in the ion source. Plasma parameters for two modifications of the standard prototype source have been investigated: Firstly, a second Cs oven has been installed in the bottom part of the back plate in addition to the regularly used oven in the top part of the back plate. Evaporation from the top oven only can lead to a vertically asymmetric Cs distribution in front of the plasma grid. Using both ovens, a symmetric Cs distribution can be reached - however, in most cases no significant change of the extracted ion current has been determined for varying Cs symmetry if the source is well-conditioned. Secondly, BATMAN has been equipped with a much larger, racetrack-shaped RF driver (area of 32×58 cm2) instead of the cylindrical RF driver (diameter of 24.5 cm). The main idea is that one racetrack driver could substitute two cylindrical drivers in larger sources with increased reliability and power efficiency. For the same applied RF power, the electron density is lower in the racetrack driver due to its five times higher volume. The fraction of hydrogen atoms to molecules, however, is at a similar level or even slightly higher, which is a promising result for application in larger sources.

  2. SU-E-I-16: Scan Length Dependency of the Radial Dose Distribution in a Long Polyethylene Cylinder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakalyar, D; McKenney, S; Feng, W

    Purpose: The area-averaged dose in the central plane of a long cylinder following a CT scan depends upon the radial dose distribution and the length of the scan. The ICRU/TG200 phantom, a polyethylene cylinder 30 cm in diameter and 60 cm long, was the subject of this study. The purpose was to develop an analytic function that could determine the dose for a scan length L at any point in the central plane of this phantom. Methods: Monte Carlo calculations were performed on a simulated ICRU/TG200 phantom under conditions of cylindrically symmetric conditions of irradiation. Thus, the radial dose distributionmore » function must be an even function that accounts for two competing effects: The direct beam makes its weakest contribution at the center while the scatter begins abruptly at the outer radius and grows as the center is approached. The scatter contribution also increases with scan length with the increase approaching its limiting value at the periphery faster than along the central axis. An analytic function was developed that fit the data and possessed these features. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the ICRU/TG200 phantom. The relative depth of the minimum decreases as the scan length grows and an absolute maximum can occur between the center and outer edge of the cylinders. As the scan length grows, the relative dip in the center decreases so that for very long scan lengths, the dose profile is relatively flat. Conclusion: An analytic function characterizes the radial and scan length dependency of dose for long cylindrical phantoms. The function can be integrated with the results expressed in closed form. One use for this is to help determine average dose distribution over the central cylinder plane for any scan length.« less

  3. Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks

    NASA Astrophysics Data System (ADS)

    Reinhart, Anna Merle; Spindeldreier, Claudia Katharina; Jakubek, Jan; Martišíková, Mária

    2017-06-01

    Carbon ion beam radiotherapy enables a very localised dose deposition. However, even small changes in the patient geometry or positioning errors can significantly distort the dose distribution. A live, non-invasive monitoring system of the beam delivery within the patient is therefore highly desirable, and could improve patient treatment. We present a novel three-dimensional method for imaging the beam in the irradiated object, exploiting the measured tracks of single secondary ions emerging under irradiation. The secondary particle tracks are detected with a TimePix stack—a set of parallel pixelated semiconductor detectors. We developed a three-dimensional reconstruction algorithm based on maximum likelihood expectation maximization. We demonstrate the applicability of the new method in the irradiation of a cylindrical PMMA phantom of human head size with a carbon ion pencil beam of {226} MeV u-1. The beam image in the phantom is reconstructed from a set of nine discrete detector positions between {-80}^\\circ and {50}^\\circ from the beam axis. Furthermore, we demonstrate the potential to visualize inhomogeneities by irradiating a PMMA phantom with an air gap as well as bone and adipose tissue surrogate inserts. We successfully reconstructed a three-dimensional image of the treatment beam in the phantom from single secondary ion tracks. The beam image corresponds well to the beam direction and energy. In addition, cylindrical inhomogeneities with a diameter of {2.85} cm and density differences down to {0.3} g cm-3 to the surrounding material are clearly visualized. This novel three-dimensional method to image a therapeutic carbon ion beam in the irradiated object does not interfere with the treatment and requires knowledge only of single secondary ion tracks. Even with detectors with only a small angular coverage, the three-dimensional reconstruction of the fragmentation points presented in this work was found to be feasible.

  4. Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks.

    PubMed

    Reinhart, Anna Merle; Spindeldreier, Claudia Katharina; Jakubek, Jan; Martišíková, Mária

    2017-06-21

    Carbon ion beam radiotherapy enables a very localised dose deposition. However, even small changes in the patient geometry or positioning errors can significantly distort the dose distribution. A live, non-invasive monitoring system of the beam delivery within the patient is therefore highly desirable, and could improve patient treatment. We present a novel three-dimensional method for imaging the beam in the irradiated object, exploiting the measured tracks of single secondary ions emerging under irradiation. The secondary particle tracks are detected with a TimePix stack-a set of parallel pixelated semiconductor detectors. We developed a three-dimensional reconstruction algorithm based on maximum likelihood expectation maximization. We demonstrate the applicability of the new method in the irradiation of a cylindrical PMMA phantom of human head size with a carbon ion pencil beam of [Formula: see text] MeV u -1 . The beam image in the phantom is reconstructed from a set of nine discrete detector positions between [Formula: see text] and [Formula: see text] from the beam axis. Furthermore, we demonstrate the potential to visualize inhomogeneities by irradiating a PMMA phantom with an air gap as well as bone and adipose tissue surrogate inserts. We successfully reconstructed a three-dimensional image of the treatment beam in the phantom from single secondary ion tracks. The beam image corresponds well to the beam direction and energy. In addition, cylindrical inhomogeneities with a diameter of [Formula: see text] cm and density differences down to [Formula: see text] g cm -3 to the surrounding material are clearly visualized. This novel three-dimensional method to image a therapeutic carbon ion beam in the irradiated object does not interfere with the treatment and requires knowledge only of single secondary ion tracks. Even with detectors with only a small angular coverage, the three-dimensional reconstruction of the fragmentation points presented in this work was found to be feasible.

  5. Testing of a First Order AC Magnetic Susceptometer

    NASA Astrophysics Data System (ADS)

    Fukuda, Ryan; Sunny, Smitha; Ho, Pei-Chun

    2011-11-01

    A first-order AC magnetic susceptometer has been constructed and tested to find the magnetic response of strongly correlated electron materials. The instrument works by using a primary coil to apply a small AC magnetic field of .104 Oe to a sample with a cylindrical coil space of length .635 cm and diameter .355 cm. A lock-in amplifier is used to monitor the induced voltage from a set of secondary coils. By coupling a temperature-controlled system with this instrument, the change in the magnetic signal with respect to temperature is measured. Monitoring the signal changes may indicate the temperature that causes the material to transition to either a ferromagnetic, anti-ferromagnetic, or superconducting state. A 122.47 mg Gd polycrystal was used to test our susceptometer. The data qualitatively agrees with the previous results of magnetization vs. temperature of Gd single crystals by Nigh et al. [1]: there is a steep increase in the pick-up signal at 300 K where Gd becomes ferromagnetic and a peak at 210 K [1]. This susceptometer will be used for our future investigation of magnetic properties of rare earth compounds and nanoparticles in the temperature range of 10 K to 300 K. [4pt] [1] H. E. Nigh, S. Legvold, and F. H. Spedding, Physical Review 132, 1092 (1963)

  6. The radiation dose from a proposed measurement of arsenic and selenium in human skin

    NASA Astrophysics Data System (ADS)

    Gherase, Mihai R.; Mader, Joanna E.; Fleming, David E. B.

    2010-09-01

    Dose measurements following 10 min irradiations with a portable x-ray fluorescence spectrometer composed of a miniature x-ray tube and a silicon PiN diode detector were performed using thermoluminescent dosimeters consisting of LiF:Mg,Ti chips of 3 mm diameter and 0.4 mm thickness. The table-top setup of the spectrometer was used for all measurements. The setup included a stainless steel lid which served as a radiation shield. Two rectangular polyethylene skin/soft tissue phantoms with two cylindrical plaster of Paris bone phantoms were used to study the effect of x-ray beam attenuation and backscatter on the measured dose. Eight different irradiation experiments were performed. The average dose rate values measured with TLD chips within a 1 × 1 cm2 area were between 4.8 and 12.8 mGy min-1. The equivalent dose for a 1 × 1 cm2 skin area was estimated to be 13.2 mSv. The maximum measured dose rate values with a single TLD chip were between 7.5 and 25.1 mGy min-1. The effective dose corresponding to a proposed arsenic/selenium skin measurement was estimated to be 0.13 µSv for a 2 min irradiation.

  7. Perform experiments on LINUS-O and LTX imploding liquid liner fusion systems. Final report 8 Sep 80-30 Sep 81

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scannell, E.P.

    1982-08-27

    The Plasma Physics Division of the Naval Research Laboratory (NRL) has been conducting investigations of imploding liquid liner fusion systems for several years (Reference 1). This effort attained a significant milestone in 1978 with the construction of two machines: HELIUS and LINUS-O. LINUS-O is a 60 MJ rotor system where a cylindrical liquid sodium - potassium (NaK) metal liner is radially compressed from a 30 cm to 1 cm diameter by gas pressure from multiple high explosive charges. These charges act on an annular piston in contact with the liquid NaK liner material. HELIUS is a half-scale vertical axis versionmore » of LINUS-O using high pressure helium to drive the annular piston. HELIUS is designed to be a test bed for new concepts and to permit testing of new modifications to LINUS-O. The principal virtue of HELIUS is its capability for ten to twenty shots per day as compared to two or three shots per day for LINUS-O. In addition, HELIUS is designed to provide higher drive pressures than were previously obtainable with water models for liner hydrodynamic studies and a magnetic flux compression capability up to approx. 100 kG.« less

  8. Headspace sorptive solid phase microextraction (HS-SPME) combined with a spectrophotometry system: A simple glass devise for extraction and simultaneous determination of cyanide and thiocyanate in environmental and biological samples.

    PubMed

    Al-Saidi, H M; Al-Harbi, Sami A; Aljuhani, E H; El-Shahawi, M S

    2016-10-01

    A simple, low cost and efficient headspace sorptive solid phase microextraction (HS-SPME) method for determination of cyanide has been developed. The system comprises of a glass tube with two valves and a moveable glass slide fixed at its centre. It includes an acceptor phase polyurethane foam treated mercury (II) dithizonate [Hg(HDz)2-PUF] complex fixed inside by a septum cap in a cylindrical configuration (5.0cm length and 1.0cm diameter). The extraction is based upon the contact of the acceptor phase to the headspace and subsequently measuring the absorbance of the recovered mercury (II) dithizonate from PUFs sorbent. Unlike other HSSE, extraction and back - extractions was carried out in a closed system, thereby improving the analytical performance by preventing the analyte loss. Under the optimized conditions, a linear calibration plot in the range of 1.0-50.0µmolL(-1) was achieved with limits of detection (LOD) and quantification (LOQ) of 0.34, 1.2µmolL(-1) CN(-), respectively. Simultaneous analysis of cyanide and thiocyanate in saliva was also performed with satisfactory recoveries. Copyright © 2016. Published by Elsevier B.V.

  9. Shockwave Interaction with a Cylindrical Structure

    NASA Astrophysics Data System (ADS)

    Mulligan, Phillip

    2017-06-01

    An increased understanding of the shockwave interaction with a cylindrical structure is the foundation for developing a method to explosively seal a pipe similar to the Deepwater Horizon accident in the Gulf of Mexico. Shockwave interactions with a cylindrical structure have been a reoccurring focus of energetics research. Some of the most notable contributions of non-destructive tests are described in ``The Effects of Nuclear Weapons'' (Glasstone, 1962). The work presented by Glasstone examines shockwave interaction from a 20-megaton bomb with a cylindrical structure. However, the data is limited to a peak overpressure of less than 25 psi, requiring several miles between the structure and the charge. The research presented in the following paper expands on the work Glasstone described by examining the shockwaves from 90, 180, and 270-gram C-4 charges interacting with a 6-inch diameter cylindrical structure positioned 52-inches from the center of the charge. The three charge weights that were tested in this research generated a peak overpressures of approximately 15, 25, and 40 psi, respectively. This research examines the peak pressure and total impulse from each charge acting on the cylindrical structure as well as the formation of vortices on the ``backside'' of the cylinder surface. This paper describes the methodology and findings of this study as well as examines the causality and implications of its results on our understanding of the shockwave interaction with a cylindrical structure.

  10. STS-48 ESC image of the MODE-01 Fluid Test Article (FTA) on OV-103's middeck

    NASA Technical Reports Server (NTRS)

    1991-01-01

    An electronic still camera (ESC) closeup shows the STS-48 Middeck Zero ('0') Gravity Dynamics Experiment 01 (MODE-01) Fluid Test Article (FTA) attached to an experimental support module (ESM) located in a forward middeck locker onboard the earth-orbiting Discovery, Orbiter Vehicle (OV) 103. The FTA is a 3.1-cm diameter cylindrical sealed Lexan tank. The FTA electromagnetic actuator has excited the test article sinusoidally, which causes the fluid inside the tank to slosh. These slosh forces, along with other data such as acceleration levels of the entire assembly, are measured by the force balance and recorded in digital form on an optical disk for later ground analysis. Crewmembers were testing the ESC as part of Development Test Objective (DTO) 648, Electronic Still Photography. The digital image was stored on a removable hard disk or small optical disk, and could be converted to a format suitable for downlink transmission. The ESC is making its initial appearance on this Space Shutt

  11. Experimental observation of standing wave effect in low-pressure very-high-frequency capacitive discharges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Yong-Xin; Gao, Fei; Liu, Jia

    2014-07-28

    Radial uniformity measurements of plasma density were carried out by using a floating double probe in a cylindrical (21 cm in electrode diameter) capacitive discharge reactor driven over a wide range of frequencies (27–220 MHz). At low rf power, a multiple-node structure of standing wave effect was observed at 130 MHz. The secondary density peak caused by the standing wave effect became pronounced and shifts toward the axis as the driving frequency further to increase, indicative of a much more shortened standing-wave wavelength. With increasing rf power, the secondary density peak shift toward the radial edge, namely, the standing-wave wavelength was increased,more » in good qualitative agreement with the previous theory and simulation results. At higher pressures and high frequencies, the rf power was primarily deposited at the periphery of the electrode, due to the fact that the waves were strongly damped as they propagated from the discharge edge into the center.« less

  12. Spherical crystals of Pb 1 - xSn xTe grown in microgravity

    NASA Astrophysics Data System (ADS)

    Kinoshita, Kyoichi; Yamada, Tomoaki

    1996-07-01

    Pb 1- xSn xTe spherical crystals were unintentionally obtained along with a cylindrical Pb 1 - xSn xTe crystal grown during the {SL-J}/{FMPT} mission on board the space shuttle "Endeavor". About 25 spherical crystals ranged from 0.5 to 11 mm in diameter. Melt leaked from the melt reservoir into the spring that plays the role of pushing the melt toward a seed crystal and eliminating free surface areas of the melt. Because of the surface tension of the melt, spherical melt drops formed in the hollow of the spring, then solidified into spherical crystals during the cooling process. Some of the crystals had lower dislocation densities, in the order of 10 4 cm -2, two orders smaller than those of terrestrially grown crystals from a melt. The experiment showed a way of stably positioning a large volume of liquid in microgravity without touching the crucible wall and a way of reducing crystalline defects by such growth.

  13. Automated digital magnetofluidics

    NASA Astrophysics Data System (ADS)

    Schneider, J.; Garcia, A. A.; Marquez, M.

    2008-08-01

    Drops can be moved in complex patterns on superhydrophobic surfaces using a reconfigured computer-controlled x-y metrology stage with a high degree of accuracy, flexibility, and reconfigurability. The stage employs a DMC-4030 controller which has a RISC-based, clock multiplying processor with DSP functions, accepting encoder inputs up to 22 MHz, provides servo update rates as high as 32 kHz, and processes commands at rates as fast as 40 milliseconds. A 6.35 mm diameter cylindrical NdFeB magnet is translated by the stage causing water drops to move by the action of induced magnetization of coated iron microspheres that remain in the drop and are attracted to the rare earth magnet through digital magnetofluidics. Water drops are easily moved in complex patterns in automated digital magnetofluidics at an average speed of 2.8 cm/s over a superhydrophobic polyethylene surface created by solvent casting. With additional components, some potential uses for this automated microfluidic system include characterization of superhydrophobic surfaces, water quality analysis, and medical diagnostics.

  14. Fixed bed pyrolysis of biomass solid waste for bio-oil

    NASA Astrophysics Data System (ADS)

    Islam, Mohammad Nurul; Ali, Mohamed Hairol Md; Haziq, Miftah

    2017-08-01

    Biomass solid waste in the form of rice husk particle is pyrolyzed in a fixed bed stainless steel pyrolysis reactor of 50 mm diameter and 50 cm length. The biomass solid feedstock is prepared prior to pyrolysis. The reactor bed is heated by means of a cylindrical heater of biomass source. A temperature of 500°C is maintained with an apperent vapor residence time of 3-5 sec. The products obtained are liquid bio-oil, solid char and gases. The liquid product yield is found to be 30% by weight of solid biomass feedstock while the solid product yield is found to be 35% by weight of solid biomass feedtock, the rest is gas. The bio-oil is a single-phase brownish color liquid of acrid smell. The heating value of the oil is determined to be 25 MJ/kg. The density and pH value are found to be 1.125 kg/m3 and 3.78 respectively.

  15. Two-phase flow research using the DC-9/KC-135 apparatus

    NASA Technical Reports Server (NTRS)

    McQuillen, John B.; Neumann, Eric S.; Shoemaker, J. Michael

    1996-01-01

    Low-gravity gas-liquid flow research can be conducted aboard the NASA Lewis Research Center DC-9 or the Johnson Space Center KC-135. Air and water solutions serve as the test liquids in cylindrical test sections with constant or variable inner diameters of approximately 2.54 cm and lengths of up to 3.0 m. Superficial velocities range from 0.1 to 1.1 m/sec for liquids and from 0.1 to 25 m/sec for air. Flow rate, differential pressure, void fraction, film thickness, wall shear stress, and acceleration data are measured and recorded at data rates of up to 1000 Hz throughout the 20-sec duration of the experiment. Flow is visualized with a high-speed video system. In addition, the apparatus has a heat-transfer capability whereby sensible heat is transferred between the test-section wall and a subcooled liquid phase so that the heat-transfer characteristics of gas-liquid two-phase flows can be determined.

  16. Laboratory plasma with cold electron temperature of the lower ionosphere

    NASA Astrophysics Data System (ADS)

    Dickson, Shannon; Robertson, Scott

    2009-10-01

    For the first time, plasma with cold electron temperatures less than 300K has been created continuously in the laboratory. The plasma is created in a cylindrical double-walled vacuum chamber in which the inner chamber (18cm in diameter and 30cm long) is wrapped in copper tubing through which vapor from liquid nitrogen flows, providing a cooling mechanism for the neutral gas. The inner chamber has two negatively-biased filaments for plasma generation and a platinum wire Langmuir probe for diagnostic measurements. Neutral gas pressures of 1.6mTorr and a total filament emission current of 2mA are used to obtain plasma densities near 4 x 10^8 cm-3. When carbon monoxide is used as the working gas, decreasing the neutral gas temperature also decreases the cold electron temperatures, yielding cold electrons with 21meV (240K) when the neutral CO is at 150K. The same experiment conducted with H2, He, or Ar results in a doubling of the cold electron temperatures, yielding 80meV (930K) when the neutral gas is at 150K. The lower electron temperature with CO is attributed to the asymmetric CO molecule having a nonzero electric dipole moment which increases the cross section for electron energy exchange. Nitric oxide, a dominant constituent of the ionosphere, has a similar dipole moment and collision cross section as carbon monoxide and is likely to be equally effective at cooling electrons.

  17. Fabrication of cylindrical micro-parts using synchronous rotary scan-projection lithography and chemical etching

    NASA Astrophysics Data System (ADS)

    Ito, Kaiki; Suzuki, Yuta; Horiuchi, Toshiyuki

    2017-07-01

    Lithographical patterning on the surface of a fine pipe with a thin wall is required for fabricating three-dimensional micro-parts. For this reason, a new exposure system for printing patterns on a cylindrical pipe by synchronous rotary scan-projection exposure was developed. Using the exposure system, stent-like resist patterns with a width of 251 μm were printed on a surface of stainless-steel pipe with an outer diameter of 2 mm. The exposure time was 30 s. Next, the patterned pipe was chemically etched. As a result, a stent-like mesh pipe with a line width of 230 μm was fabricated. It was demonstrated that the new method had a potential to be applied to fabrications of stent and other cylindrical micro-parts.

  18. The sagitta and lens thickness: the exact solution and a matrix approximation for lenses with toric, spherical, and cylindrical surfaces.

    PubMed

    Harris, W F

    1989-03-01

    The exact equation for sagitta of spherical surfaces is generalized to toric surfaces which include spherical and cylindrical surfaces as special cases. Lens thickness, therefore, can be calculated accurately anywhere on a lens even in cases of extreme spherical and cylindrical powers and large diameters. The sagittae of tire- and barrel-form toric surfaces differ off the principal meridians, as is shown by a numerical example. The same holds for pulley- and capstan-form toric surfaces. A general expression is given for thickness at an arbitrary point on a toric lens. Approximate expressions are derived and re-expressed in terms of matrices. The matrix provides an elegant means of generalizing equations for spherical surfaces and lenses to toric surfaces and lenses.

  19. Performance Evaluation and Initial Clinical Test of the Positron Emission Mammography System (PEMi)

    NASA Astrophysics Data System (ADS)

    Li, Lin; Gu, Xiao-Yue; Li, Dao-Wu; Huang, Xian-Chao; Chai, Pei; Feng, Bao-Tong; Wang, Pei-Lin; Yun, Ming-Kai; Dai, Dong; Zhang, Zhi-Ming; Yin, Peng-Fei; Xu, Wen-Gui; Wei, Long

    2015-10-01

    A new polygon positron emission mammography imaging system (PEMi) was developed in 2009 by the Institute of High Energy Physics, Chinese Academy of Sciences. PEMi is constructed in a polygon structure with lutetium yttrium orthosilicate crystal arrays mounted on a position-sensitive photomultiplier. The system consists of 64 blocks and each block is arranged in 16 ×16 crystal arrays with a pixel size of 1.9 ×1.9 ×15 mm. The diameter of the detector ring is 166 mm, and the axial length is 128 mm. The transaxial field of view of PEMi is 110 mm. The goal of the initial study was to test PEMi's performance and the clinical imaging ability with a small group of selected subjects. The detectors have a measured intrinsic spatial resolution averaging 1.67 mm. The axial and tangential resolution remained under 2.5-mm full width at half maximum within the central 5-cm diameter of the field of view. The hot rods with a diameter of 1.7 mm can be clearly identified, and the structure of the region containing 1.35-mm diameter rods can also be observed. Using a 6-ns coincidence timing window and a 360 660-keV energy window, the peak sensitivity of the tomograph is 6.88%. The noise-equivalent count rate peak is 110 766 cps for a breast-like cylindrical phantom of 100 mm in diameter at an activity concentration of 0.03 MBq/cc. The recovery coefficients ranged from 0.21 to 0.85 for rods between 1 mm and 5 mm in the image-quality phantom. The reconstructed image resolution achieved an improvement compared with whole-body positron emission tomography (PET), which might reduce the lower threshold on detectable lesion size. Example patient images demonstrate that PEMi is clinically feasible. And more detailed structure information was obtained with PEMi than with the whole-body PET imaging.

  20. Evaluation of collimation and imaging configuration in scintimammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsui, B.M.W.; Frey, E.C.; Wessell, D.E.

    1996-12-31

    Conventional scintimammography (SM) with {sup 99m}Tc sestamibi has been limited to taking a single lateral view of the breast using a parallel-hole high resolution (LEHR) collimator. The collimator is placed close to the breast for best possible spatial resolution. However, the collimator geometry precludes imaging the breast from other views. We evaluated using a pinhole collimator instead of a LEHR collimator in SM for improved spatial resolution and detection efficiency, and to allow additional imaging views. Results from theoretical calculations indicated that pinhole collimators could be designed with higher spatial resolution and detection efficiency than LEHR when imaging small tomore » medium size breasts. The geometrical shape of the pinhole collimator allows imaging of the breasts from both the lateral and craniocaudal views. The dual-view images allow better determination of the location of the tumors within the breast and improved detection of tumors located in the medial region of the breast. A breast model that simulates the shape and composition of the breast and breast tumors with different sizes and locations was added to an existing 3D mathematical cardiac-torso (MCAT) phantom. A cylindrically shaped phantom with 10 cm diameter and spherical inserts with different sizes and {sup 99m}Tc sestamibi uptakes with respect to the background provide physical models of breast with tumors. Simulation studies using the breast and MCAT phantoms and experimental studies using the cylindrical phantom confirmed the utility of the pinhole collimator in SM for improved breast tumor detection.« less

  1. Compensating for Attenuation Differences in Ultrasonic Inspections of Titanium-Alloy Billets

    NASA Astrophysics Data System (ADS)

    Margetan, F. J.; Thompson, R. B.; Keller, Michael; Hassan, Waled

    2004-02-01

    Cylindrical billets of Titanium alloy are ultrasonically inspected prior to use in fabricating rotating jet-engine components. Although each billet has a cylindrical geometry, its ultrasonic properties are not cylindrically symmetric due to asymmetries in the process used to produce the billet from the original cast ingot. In the inspection process, a calibration standard of the same diameter containing flat-bottomed hole (FBH) reflectors is used to set the initial inspection gain (i.e., the signal amplification level). If the ultrasonic attenuation of the billet to be inspected differs significantly from that of the calibration standard, the inspection gain must be adjusted to maintain the desired defect detection sensitivity. In this paper we investigate several schemes for attenuation compensation. The gain adjustments fall into two broad categories: "global" adjustments (in dB/inch units), which are applied uniformly throughout the billet under inspection; and "local adjustments", which vary with axial and circumferential position. The schemes make use of the patterns of reflected back-wall amplitude and backscattered grain noise seen in the calibration standard and test billet. The various compensation schemes are tested using specimens of 6″-diameter Ti-6A1-4V billet into which many FBH targets were drilled. Results are summarized and tentative recommendations for improving billet inspection practices are offered.

  2. Analysis of dry friction damping characteristics for short cylindrical shell structures

    NASA Astrophysics Data System (ADS)

    Wang, Nengmao; Wang, Yanrong

    2018-05-01

    An efficient mathematical model to describe the friction of short cylindrical shell structures with a dry friction damping sleeve is proposed. The frictional force in the circumference and axial direction is caused by the opposing bending strains at the interface. Slipping will occur at part region of the interface and the mathematic model of the slipping region is established. Ignoring the effect of contact stiffness on the vibration analysis, the friction energy dissipation capability of damping sleeve would be calculated. Structural vibration mode, positive pressure at the interface and vibration stress of the short cylindrical shell structures is analyzed as influence factors to the critical damping ratio. The results show that the circumferential friction energy dissipation is more sensitive to the number of nodal diameter, and the circumferential friction damping ratio increases rapidly with the number of nodal diameter. The slipping frictional force would increase along with the positive pressure, but the slipping region would decrease with it. The peak damping ratio keeps nearly constant. But the vibration stress corresponding to peak damping ratio would increases with the positive pressure. The dry friction damping ratio of damping sleeve contains the effect of frictional force in the circumference and axial direction, and the axial friction plays a major role.

  3. Microfluidic step-emulsification in a cylindrical geometry

    NASA Astrophysics Data System (ADS)

    Chakraborty, Indrajit; Leshansky, Alexander M.

    2016-11-01

    The model microfluidic device for high-throughput droplet generation in a confined cylindrical geometry is investigated numerically. The device comprises of core-annular pressure-driven flow of two immiscible viscous liquids through a cylindrical capillary connected co-axially to a tube of a larger diameter through a sudden expansion, mimicking the microfluidic step-emulsifier (1). To study this problem, the numerical simulations of axisymmetric Navier-Stokes equations have been carried out using an interface capturing procedure based on coupled level set and volume-of-fluid (CLSVOF) methods. The accuracy of the numerical method was favorably tested vs. the predictions of the linear stability analysis of core-annular two-phase flow in a cylindrical capillary. Three distinct flow regimes can be identified: the dripping (D) instability near the entrance to the capillary, the step- (S) and the balloon- (B) emulsification at the step-like expansion. Based on the simulation results we present the phase diagram quantifying transitions between various regimes in plane of the capillary number and the flow-rate ratio. MICROFLUSA EU H2020 project.

  4. Cylindrical acoustic levitator/concentrator having non-circular cross-section

    DOEpatents

    Kaduchak, Gregory; Sinha, Dipen N.

    2003-11-11

    A low-power, inexpensive acoustic apparatus for levitation and/or concentration of aerosols and small liquid/solid samples having particulates up to several millimeters in diameter in air or other fluids is described. It is constructed from a commercially available, hollow piezoelectric crystal which has been formed with a cylindrical cross-section to tune the resonance frequency of the breathing mode resonance of the crystal to that of the interior cavity of the cylinder. When the resonance frequency of the interior cylindrical cavity is matched to the breathing mode resonance of the cylindrical piezoelectric transducer, the acoustic efficiency for establishing a standing wave pattern in the cavity is high. By deforming the circular cross-section of the transducer, the acoustic force is concentrated along axial regions parallel to the axis of the transducer. The cylinder does not require accurate alignment of a resonant cavity. The concentrated regions of acoustic force cause particles in the fluid to concentrate within the regions of acoustic force for separation from the fluid.

  5. The prevalence of cervical myelopathy among subjects with narrow cervical spinal canal in a population-based magnetic resonance imaging study: the Wakayama Spine Study.

    PubMed

    Nagata, Keiji; Yoshimura, Noriko; Hashizume, Hiroshi; Muraki, Shigeyuki; Ishimoto, Yuyu; Yamada, Hiroshi; Takiguchi, Noboru; Nakagawa, Yukihiro; Minamide, Akihito; Oka, Hiroyuki; Kawaguchi, Hiroshi; Nakamura, Kozo; Akune, Toru; Yoshida, Munehito

    2014-12-01

    A narrow cervical spinal canal (CSC) is a well-known risk factor for cervical myelopathy (CM). However, no epidemiologic data of the CSC based on a population-based cohort are available. The purpose of the study was to investigate the age-related differences in CSC diameters on plain radiographs and to examine the associated magnetic resonance imaging (MRI) abnormalities including cervical cord compression and increased signal intensity (ISI) as well as the clinical CM with the narrow CSC. This was a cross-sectional study. Data were obtained from the baseline survey of the Wakayama Spine Study that was performed from 2008 to 2010 in a western part of Japan. Finally, a total of 959 subjects (319 men and 640 women; mean age, 66.4 years) were included. The outcome measures included in the study were the CSC diameter at C5 level on plain radiographs, cervical cord compression and ISI on sagittal T2-weighted MRI, and physical signs related to CM (eg, the Hoffmann reflex, hyperreflexia of the patellar tendon, the Babinski reflex, sensory and motor function, and bowel/bladder symptoms). The age-related differences of CSC diameters in men and women were investigated by descriptive statistics. The prevalence of MRI abnormalities and clinical CM was compared among the groups divided by the CSC diameter (less than 13, 13-15, and 15 mm or more). In addition, a logistic regression analysis was performed to determine the association of the CSC diameter with cervical cord compression/clinical CM after overall adjustment for age, sex, and body mass index. The CSC diameter was narrower with increasing age in both men and women. The prevalence of cervical cord compression, ISI, and the clinical CM was significantly higher in the narrower CSC group. The prevalence of cervical cord compression, ISI, and CM among subjects with CSC diameter less than 13 mm was 38.0%, 5.4%, and 10.1%, respectively. In the logistic model, the CSC diameter was a significant predictive factor for the clinical CM (p<.0001). This study firstly confirmed the age-related differences in CSC diameters and the significant association of the narrow CSC diameter with CM in a population-based cohort. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Development of a superconducting bulk magnet for NMR and MRI.

    PubMed

    Nakamura, Takashi; Tamada, Daiki; Yanagi, Yousuke; Itoh, Yoshitaka; Nemoto, Takahiro; Utumi, Hiroaki; Kose, Katsumi

    2015-10-01

    A superconducting bulk magnet composed of six vertically stacked annular single-domain c-axis-oriented Eu-Ba-Cu-O crystals was energized to 4.74 T using a conventional superconducting magnet for high-resolution NMR spectroscopy. Shim coils, gradient coils, and radio frequency coils for high resolution NMR and MRI were installed in the 23 mm-diameter room-temperature bore of the bulk magnet. A 6.9 ppm peak-to-peak homogeneous region suitable for MRI was achieved in the central cylindrical region (6.2 mm diameter, 9.1 mm length) of the bulk magnet by using a single layer shim coil. A 21 Hz spectral resolution that can be used for high resolution NMR spectroscopy was obtained in the central cylindrical region (1.3 mm diameter, 4 mm length) of the bulk magnet by using a multichannel shim coil. A clear 3D MR image dataset of a chemically fixed mouse fetus with (50 μm)(3) voxel resolution was obtained in 5.5 h. We therefore concluded that the cryogen-free superconducting bulk magnet developed in this study is useful for high-resolution desktop NMR, MRI and mobile NMR device. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Development of Ordered, Porous (Sub-25 nm Dimensions) Surface Membrane Structures Using a Block Copolymer Approach.

    PubMed

    Ghoshal, Tandra; Holmes, Justin D; Morris, Michael A

    2018-05-08

    In an effort to develop block copolymer lithography to create high aspect vertical pore arrangements in a substrate surface we have used a microphase separated poly(ethylene oxide) -b- polystyrene (PEO-b-PS) block copolymer (BCP) thin film where (and most unusually) PS not PEO is the cylinder forming phase and PEO is the majority block. Compared to previous work, we can amplify etch contrast by inclusion of hard mask material into the matrix block allowing the cylinder polymer to be removed and the exposed substrate subject to deep etching thereby generating uniform, arranged, sub-25 nm cylindrical nanopore arrays. Briefly, selective metal ion inclusion into the PEO matrix and subsequent processing (etch/modification) was applied for creating iron oxide nanohole arrays. The oxide nanoholes (22 nm diameter) were cylindrical, uniform diameter and mimics the original BCP nanopatterns. The oxide nanohole network is demonstrated as a resistant mask to fabricate ultra dense, well ordered, good sidewall profile silicon nanopore arrays on substrate surface through the pattern transfer approach. The Si nanopores have uniform diameter and smooth sidewalls throughout their depth. The depth of the porous structure can be controlled via the etch process.

  8. Reaction of Titanium and Zirconium Particles in Cylindrical Explosive Charges

    NASA Astrophysics Data System (ADS)

    Frost, David L.; Cairns, Malcolm; Goroshin, Samuel; Zhang, Fan

    2007-12-01

    The critical conditions for the reaction of particles of the transition metals titanium (Ti) and zirconium (Zr) dispersed during the detonation of long cylindrical explosive charges have been investigated experimentally. The charges consisted of packed beds of either spherical Ti particles or irregularly shaped Zr particles saturated with sensitized liquid nitromethane. For the Ti particles, a threshold particle diameter exists of 65±25 μm, above which self-sustained particle reaction is not observed for charge diameters up to 49 mm, although some particle reaction occurs immediately behind the detonation front then rapidly quenches. For the smallest particles (40 μm), the proportion of the conical particle cloud that reacts increases with charge diameter, suggesting that the reaction is a competition between particle heating and expansion cooling of the products. For 375 and 550 μm Zr particles, particle ignition was observed for 19 and 41 mm dia charges. In this case, interaction of the detonation wave with the particles is sufficient to initiate reaction at the particle surface after a delay time (˜5 μs), which is much less than the time required for thermal equilibration of the particles.

  9. Liquid oxygen dicting cleaned by falling film method

    NASA Technical Reports Server (NTRS)

    Paul, H. I.

    1967-01-01

    Principle of a vertical falling film is used to clean contaminated large diameter and length liquid oxygen /LOX/ cylindrical ducting. The cleaning cycle is performed by flowing trichloroethylene in a falling film down a vertically mounted duct for approximately one hour.

  10. Investigation of the Arcjet near Field Plume Using Electrostatic Probes

    NASA Technical Reports Server (NTRS)

    Sankovic, John M.

    1990-01-01

    The near field plume of a 1 kW class arcjet thruster was investigated using electrostatic probes of various geometries. The electron number densities and temperatures were determined in a simulated hydrazine plume at axial distances between 3 cm (1.2 in.) and 15 cm (5.9 in.) and radial distances extending to 10 cm (3.9 in.) off centerline. Values of electron number densities obtained using cylindrical and spherical probes of different geometries agreed very well. The electron density on centerline followed a source flow approximation for axial distances as near as 3 cm (1.2 in.) from the nozzle exit plane. The model agreed well with previously obtained data in the far field. The effects of propellant mass flow rate and input power level were also studied. Cylindrical probes were used to obtain ion streamlines by changing the probe orientation with respect to the flow. The effects of electrical configuration on the plasma characteristics of the plume were also investigated by using a segmented anode/nozzle thruster. The results showed that the electrical configuration in the nozzle affected the distribution of electrons in the plume.

  11. Investigation of the arcjet plume near field using electrostatic probes

    NASA Technical Reports Server (NTRS)

    Sankovic, John M.

    1990-01-01

    The near field plum of a 1 kW class arcjet thruster was investigated using electrostatic probes of various geometries. The electron number densities and temperatures were determined in a simulated hydrazine plume at axial distances between 3 cm (1.2 in) and 15 cm (5.9 in) and radial distances extending to 10 cm (3.9 in) off centerline. Values of electron number densities obtained using cylindrical and spherical probes of different geometries agreed very well. The electron density on centerline followed a source flow approximation for axial distances as near as 3 cm (1.2 in) from the nozzle exit plane. The model agreed well with previously obtained data in the far field. The effects of propellant mass flow rate and input power level were also studied. Cylindrical probes were used to obtain ion streamlines by changing the probe orientation with respect to the flow. The effects of electrical configuration on the plasma characteristics of the plume were also investigated by using a segmented anode/nozzle thruster. The results showed that the electrical configuration in the nozzle affected the distribution of electrons in the plume.

  12. Digital terrestrial photogrammetric methods for tree stem analysis

    Treesearch

    Neil A. Clark; Randolph H. Wynne; Daniel L. Schmoldt; Matt Winn

    2000-01-01

    A digital camera was used to measure diameters at various heights along the stem on 20 red oak trees. Diameter at breast height ranged from 16 to over 60 cm, and height to a 10-cm top ranged from 12 to 20 m. The chi-square maximum anticipated error of geometric mean diameter estimates at the 95 percent confidence level was within ±4 cm for all heights when...

  13. Unique growth strategy in the Earth's first trees revealed in silicified fossil trunks from China.

    PubMed

    Xu, Hong-He; Berry, Christopher M; Stein, William E; Wang, Yi; Tang, Peng; Fu, Qiang

    2017-11-07

    Cladoxylopsida included the earliest large trees that formed critical components of globally transformative pioneering forest ecosystems in the Mid- and early Late Devonian (ca. 393-372 Ma). Well-known cladoxylopsid fossils include the up to ∼1-m-diameter sandstone casts known as Eospermatopteris from Middle Devonian strata of New York State. Cladoxylopsid trunk structure comprised a more-or-less distinct cylinder of numerous separate cauline xylem strands connected internally with a network of medullary xylem strands and, near the base, externally with downward-growing roots, all embedded within parenchyma. However, the means by which this complex vascular system was able to grow to a large diameter is unknown. We demonstrate-based on exceptional, up to ∼70-cm-diameter silicified fossil trunks with extensive preservation of cellular anatomy from the early Late Devonian (Frasnian, ca. 374 Ma) of Xinjiang, China-that trunk expansion is associated with a cylindrical zone of diffuse secondary growth within ground and cortical parenchyma and with production of a large amount of wood containing both rays and growth increments concentrically around individual xylem strands by normal cambia. The xylem system accommodates expansion by tearing of individual strand interconnections during secondary development. This mode of growth seems indeterminate, capable of producing trees of large size and, despite some unique features, invites comparison with secondary development in some living monocots. Understanding the structure and growth of cladoxylopsids informs analysis of canopy competition within early forests with the potential to drive global processes. Published under the PNAS license.

  14. Generation of scalable terahertz radiation from cylindrically focused two-color laser pulses in air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuk, D.; Yoo, Y. J.; Rosenthal, E. W.

    2016-03-21

    We demonstrate scalable terahertz (THz) generation by focusing terawatt, two-color laser pulses in air with a cylindrical lens. This focusing geometry creates a two-dimensional air plasma sheet, which yields two diverging THz lobe profiles in the far field. This setup can avoid plasma-induced laser defocusing and subsequent THz saturation, previously observed with spherical lens focusing of high-power laser pulses. By expanding the plasma source into a two-dimensional sheet, cylindrical focusing can lead to scalable THz generation. This scheme provides an energy conversion efficiency of 7 × 10{sup −4}, ∼7 times better than spherical lens focusing. The diverging THz lobes are refocused withmore » a combination of cylindrical and parabolic mirrors to produce strong THz fields (>21 MV/cm) at the focal point.« less

  15. An inverted cylindrical sputter magnetron as metal vapor supply for electron cyclotron resonance ion sources.

    PubMed

    Weichsel, T; Hartung, U; Kopte, T; Zschornack, G; Kreller, M; Silze, A

    2014-05-01

    An inverted cylindrical sputter magnetron device has been developed. The magnetron is acting as a metal vapor supply for an electron cyclotron resonance (ECR) ion source. FEM simulation of magnetic flux density was used to ensure that there is no critical interaction between both magnetic fields of magnetron and ECR ion source. Spatially resolved double Langmuir probe and optical emission spectroscopy measurements show an increase in electron density by one order of magnitude from 1 × 10(10) cm(-3) to 1 × 10(11) cm(-3), when the magnetron plasma is exposed to the magnetic mirror field of the ECR ion source. Electron density enhancement is also indicated by magnetron plasma emission photography with a CCD camera. Furthermore, photographs visualize the formation of a localized loss-cone - area, when the magnetron is operated at magnetic mirror field conditions. The inverted cylindrical magnetron supplies a metal atom load rate of R > 1 × 10(18) atoms/s for aluminum, which meets the demand for the production of a milliampere Al(+) ion beam.

  16. Fabrication of High Performing PEMFC Catalyst-Coated Membranes with a Low Cost Air-Assisted Cylindrical Liquid Jets Spraying System

    DOE PAGES

    Peng, Xiong; Omasta, Travis; Rigdon, William; ...

    2016-11-15

    In this paper, a low cost air-assisted cylindrical liquid jets spraying (ACLJS) system was developed to prepare high-performance catalyst-coated membranes (CCMs) for proton exchange membrane fuel cells (PEMFCs). The catalyst ink was flowed from a cylindrical orifice and was atomized by an air stream fed from a coaxial slit and sprayed directly onto the membrane, which was suctioned to a heated aluminum vacuum plate. The CCM pore architecture including size, distribution and volume can be controlled using various flow parameters, and the impact of spraying conditions on electrode structure and PEMFC performance was investigated. CCMs fabricated in the fiber-type break-upmore » regime by ACLJS achieved very high performance during PEMFC testing, with the top-performing cells having a current density greater than 1900 mA/cm 2 at 0.7 V under H 2/O 2 flows and 700 mA/cm 2 under H 2/Air at 1.5 bar(absolute) pressure and 60% gas RH, and 80°C cell temperature.« less

  17. Fabrication of High Performing PEMFC Catalyst-Coated Membranes with a Low Cost Air-Assisted Cylindrical Liquid Jets Spraying System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peng, Xiong; Omasta, Travis; Rigdon, William

    In this paper, a low cost air-assisted cylindrical liquid jets spraying (ACLJS) system was developed to prepare high-performance catalyst-coated membranes (CCMs) for proton exchange membrane fuel cells (PEMFCs). The catalyst ink was flowed from a cylindrical orifice and was atomized by an air stream fed from a coaxial slit and sprayed directly onto the membrane, which was suctioned to a heated aluminum vacuum plate. The CCM pore architecture including size, distribution and volume can be controlled using various flow parameters, and the impact of spraying conditions on electrode structure and PEMFC performance was investigated. CCMs fabricated in the fiber-type break-upmore » regime by ACLJS achieved very high performance during PEMFC testing, with the top-performing cells having a current density greater than 1900 mA/cm 2 at 0.7 V under H 2/O 2 flows and 700 mA/cm 2 under H 2/Air at 1.5 bar(absolute) pressure and 60% gas RH, and 80°C cell temperature.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shah, Jainil P., E-mail: jainil.shah@duke.edu; Mann, Steve D.; McKinley, Randolph L.

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source fluxmore » was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.« less

  19. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    PubMed Central

    Shah, Jainil P.; Mann, Steve D.; McKinley, Randolph L.; Tornai, Martin P.

    2015-01-01

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm3 voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements. PMID:26233179

  20. Anatomic characteristics of ruptured abdominal aortic aneurysm on conventional CT scans: Implications for rupture risk.

    PubMed

    Fillinger, Mark F; Racusin, Jessica; Baker, Robert K; Cronenwett, Jack L; Teutelink, Arno; Schermerhorn, Marc L; Zwolak, Robert M; Powell, Richard J; Walsh, Daniel B; Rzucidlo, Eva M

    2004-06-01

    The purpose of this study was to analyze anatomic characteristics of patients with ruptured abdominal aortic aneurysms (AAAs), with conventional two-dimensional computed tomography (CT), including comparison with control subjects matched for age, gender, and size. Records were reviewed to identify all CT scans obtained at Dartmouth-Hitchcock Medical Center or referring hospitals before emergency AAA repair performed because of rupture or acute severe pain (RUP group). CT scans obtained before elective AAA repair (ELEC group) were reviewed for age and gender match with patients in the RUP group. More than 40 variables were measured on each CT scan. Aneurysm diameter matching was achieved by consecutively deleting the largest RUP scan and the smallest ELEC scan to prevent bias. CT scans were analyzed for 259 patients with AAAs: 122 RUP and 137 ELEC. Patients were well matched for age, gender, and other demographic variables or risk factors. Maximum AAA diameter was significantly different in comparisons of all patients (RUP, 6.5 +/- 2 cm vs ELEC, 5.6 +/- 1 cm; P <.0001), and mean diameter of ruptured AAAs was 5 mm smaller in female patients (6.1 +/- 2 cm vs 6.6 +/- 2 cm; P =.007). Two hundred patients were matched for diameter, gender, and age (100 from each group; maximum AAA diameter, 6.0 +/- 1 cm vs 6.0 +/- 1 cm). Analysis of diameter-matched AAAs indicated that most variables were statistically similar in the two groups, including infrarenal neck length (17 +/- 1 mm vs 19 +/- 1 mm; P =.3), maximum thrombus thickness (25 +/- 1 mm vs 23 +/- 1 mm, P =.4), and indices of body habitus, such as [(maximum AAA diameter)/(normal suprarenal aorta diameter)] or [(maximum AAA diameter)/(L3 transverse diameter)]. Multivariate analysis controlling for gender indicated that the most significant variables for rupture were aortic tortuosity (odds ratio [OR] 3.3, indicating greater risk with no or mild tortuosity), diameter asymmetry (OR, 3.2 for a 1-cm difference in major-minor axis), and current smoking (OR, 2.7, with the greater risk in current smokers). When matched for age, gender, and diameter, ruptured AAAs tend to be less tortuous, yet have greater cross-sectional diameter asymmetry. On conventional two-dimensional CT axial sections, it appears that when diameter asymmetry is associated with low aortic tortuosity, the larger diameter on axial sections more accurately reflects rupture risk, and when diameter asymmetry is associated with moderate or severe aortic tortuosity, the smaller diameter on axial sections more accurately reflects rupture risk. Current smoking is significantly associated with rupture, even when controlling for gender and AAA anatomy.

  1. Compressible sleeve provides automatic centering for grinding or turning of cylinders

    NASA Technical Reports Server (NTRS)

    Rohrer, J. A.

    1968-01-01

    Elastomeric sleeve supported on a threaded mandrel automatically centers cylindrical castings for grinding or turning. By expanding the diameter of the sleeve with pressure against the ends, the casting becomes rigidly supported and the surfacing operation can be completed.

  2. Analyzing the Influence of a New Dental Implant Design on Primary Stability.

    PubMed

    Valente, Mariana Lima da Costa; de Castro, Denise Tornavoi; Shimano, Antonio Carlos; Lepri, César Penazzo; dos Reis, Andréa Cândido

    2016-02-01

    The macrogeometry of dental implants strongly influences the primary stability and hence the osseointegration process. Compare the performance of conventional and modified implant models in terms of primary stability. A total of 36 implants (Neodent®) with two different formats (n = 18): Alvim CM (Conical CM, Ø 4.3 mm × 10 mm in length) and Titamax Ti (Cylindrical HE, Ø 4.0 mm × 11 mm in length) were inserted into artificial bone blocks. Nine implants from each set were selected to undergo external geometry changes. The primary stability was quantified by insertion torque and resonance frequency using an Osstell device and the pullout test. One-way analysis of variance and Tukey's test were used for statistical evaluation. The comparative analysis of the implants showed a significant increase of the insertion torque for the modified Conical CM implants (p = 0.000) and Cylindrical HE (p = 0.043); for the resonance frequency the modified Cylindrical HE showed a lower statistical mean (p = 0.002) when compared to the conventional model, and in the pullout test both modified implants showed significant reduction (p = 0.000). Within the limitations of this study, the proposed modification showed good stability levels and advantages when compared to the conventional implants. © 2015 Wiley Periodicals, Inc.

  3. Phospholipid Nonwoven Electrospun Membranes

    NASA Astrophysics Data System (ADS)

    McKee, Matthew G.; Layman, John M.; Cashion, Matthew P.; Long, Timothy E.

    2006-01-01

    Nonwoven fibrous membranes were formed from electrospinning lecithin solutions in a single processing step. As the concentration of lecithin increased, the micellar morphology evolved from spherical to cylindrical, and at higher concentrations the cylindrical micelles overlapped and entangled in a fashion similar to polymers in semi-dilute or concentrated solutions. At concentrations above the onset of entanglements of the wormlike micelles, electrospun fibers were fabricated with diameters on the order of 1 to 5 micrometers. The electrospun phospholipid fibers offer the potential for direct fabrication of biologically based, high-surface-area membranes without the use of multiple synthetic steps, complicated electrospinning designs, or postprocessing surface treatments.

  4. Supercooling Water in Cylindrical Capsules

    NASA Astrophysics Data System (ADS)

    Guzman, J. J. Milón; Braga, S. L.

    2005-11-01

    An experimental apparatus was developed to investigate the supercooling phenomenon of water inside cylindrical capsules used for a cold storage process. The coolant is a water-alcohol mixture controlled by a constant temperature bath (CTB). Temperatures varying with time are measured inside and outside the capsule. Cylinders with an internal diameter and thickness of 45 and 1.5 mm, respectively, were made from four different materials: acrylic, PVC, brass, and aluminum. The supercooling period of the water and the nucleation temperature were investigated for different coolant temperatures. The supercooling and nucleation probabilities are shown as a function of the coolant temperature for the four different materials.

  5. Investigation of Perforated Convergent-divergent Diffusers with Initial Boundary Layer

    NASA Technical Reports Server (NTRS)

    Weinstein, Maynard I

    1950-01-01

    An experimental investigation was made at Mach number 1.90 of the performance of a series of perforated convergent-divergent supersonic diffusers operating with initial boundary layer, which was induced and controlled by lengths of cylindrical inlets affixed to the diffusers. Supercritical mass-flow and peak total-pressure recoveries were decreased slightly by use of the longest inlets (4 inlet diameters in length). Combinations of cylindrical inlets, perforated diffusers, and subsonic diffuser were evaluated as simulated wind tunnels having second throats. Comparisons with noncontracted configurations of similar scale indicated conservatively computed power reductions of 25 percent.

  6. Technical characterization of an ultrasound source for noninvasive thermoablation by high-intensity focused ultrasound.

    PubMed

    Köhrmann, K U; Michel, M S; Steidler, A; Marlinghaus, E; Kraut, O; Alken, P

    2002-08-01

    To develop a generator for high-intensity focused ultrasound (HIFU, a method of delivering ultrasonic energy with resultant heat and tissue destruction to a tight focus at a selected depth within the body), designed for extracorporeal coupling to allow various parenchymal organs to be treated. The ultrasound generated by a cylindrical piezo-ceramic element is focused at a depth of 10 cm using a parabolic reflector with a diameter of 10 cm. A diagnostic B-mode ultrasonographic transducer is integrated into the source to allow the focus to be located in the target area. The field distribution of the sound pressure was measured in degassed water using a needle hydrophone. An ultrasound-force balance was used to determine the acoustic power. These measurements allowed the spatially averaged sound intensity to be calculated. The morphology and extent of tissue necrosis induced by HIFU was examined on an ex-vivo kidney model. The two-dimensional field distribution resulted in an approximately ellipsoidal focus of 32 x 4 mm (- 6 dB). The spatially maximum averaged sound intensity was 8591 W/cm2 at an electrical power of 400 W. The lesion caused to the ex-vivo kidney at this maximum generator power with a pulse duration of 2 s was a clearly delineated ellipsoidal coagulation necrosis up to 8.8 x 2.3 mm (length x width) and with central liquefied necrosis of 7.9 x 1.9 mm. This newly developed ultrasound generator with a focal length of 10 cm can induce clear necrosis in parenchymal tissue. Because of its specific configuration and the available power range of the ultrasound generator, there is potential for therapeutic noninvasive ablation of tissue deep within a patient's body.

  7. In vitro large diameter bowel anastomosis using a temperature controlled laser tissue soldering system and albumin stent.

    PubMed

    Spector, David; Rabi, Yaron; Vasserman, Irena; Hardy, Amos; Klausner, Joseph; Rabau, Micha; Katzir, Abraham

    2009-09-01

    In today's age of advancing surgical technology, there is a need for better and simpler methods of tissue bonding. The use of lasers for tissue welding or soldering is one of these sutureless methods. In 30 years of laser tissue bonding (LTB) research, published reports of cylindrical organ anastomosis were limited to small diameters. The tension resisted by the anastomosis, which is caused by the intraluminal pressure, is also proportional to the organ diameter. Therefore the anastomosis of large diameter organs requires significantly stronger mechanical strength. The aim of this study is to demonstrate such an anastomosis. In vitro anastomosis of porcine small bowel was performed by either LTB or sutures. Anastomosis in the laser group (number of samples, n = 15) included two main stages of soldering. The bowel edges were approximated over a solid albumin stent and heated with a temperature controlled GaAs laser system to 75 degrees C. This was followed by spreading liquid albumin on the anastomotic line and heating by the same system again to 75 degrees C. The control group (n = 5) was sutured anastomosis. All anastomoses were assessed by burst pressure measurement. The burst pressure of the laser group attained 170+/-40 mmHg which was significantly higher than that of the sutured group 83+/-37 mmHg (P < 0.001). This report describes the in vitro LTB anastomosis of a large diameter cylindrical organ. The immediate bond strength, as estimated by burst pressure measurements, was double compared to sutured anastomosis.

  8. Optical distortion correction of a liquid-gas interface and contact angle in cylindrical tubes

    NASA Astrophysics Data System (ADS)

    Darzi, Milad; Park, Chanwoo

    2017-05-01

    Objects inside cylindrical tubes appear distorted as seen outside the tube due to the refraction of the light passing through different media. Such an optical distortion may cause significant errors in geometrical measurements using optical observations of objects (e.g., liquid-gas interfaces, solid particles, gas bubbles) inside the tubes. In this study, an analytical method using a point-by-point correction of the optical distortion was developed. For an experimental validation, the method was used to correct the apparent profiles of the water-air interfaces (menisci) in cylindrical glass tubes with different tube diameters and wall thicknesses. Then, the corrected meniscus profiles were used to calculate the corrected static contact angles. The corrected contact angle shows an excellent agreement with the reference contact angles as compared to the conventional contact angle measurement using apparent meniscus profiles.

  9. Growth characteristics of mangrove seedling in silvofishery pond – the allometric relationship of height, diameter and leaf abundance

    NASA Astrophysics Data System (ADS)

    Dwi Hastuti, Endah; Budi Hastuti, Rini

    2018-03-01

    Dynamic environment condition of the silvofishery pond should provide an effect on the growth of mangrove seedling. This research aimed to observe the morphometric growth rate of mangrove seedling of Avicennia marina and Rhizophora mucronata planted in the silvofishery pond and to analyze the morphometric growth relationship of height, diameter and leaf number development of mangrove seedling. The research was conducted through field experiment involving mangrove species of A. marina and R. mucronata for 18 months during March 2015 to September 2016, both single structured and mixed structure. The observation was conducted every 13 weeks including seedling height, diameter and number of leaves. Data analysis was conducted by regression to provide the statistical relation between the growth of diameter – height, diameter – number of leaves and height – number of leaves. The result showed that the growth rate of A. marina in single structured pond was ranged from 0.38 – 3.00 cm.wk-1, 0.0015 – 0.0969 cm.wk‑1 and 0.1 – 13.7 leaves.wk‑1 respectively for height, diameter and number of leaves, while in mixed structure was 0.23 – 1.69 cm.wk‑1, 0.0169 – 0.0731 cm.wk‑1 and 0.5 – 14.0 leaves.wk-. The growth of R. mucronata respectively in single and mixed structure were 0.08 – 2.00 cm.wk‑1 and 0.15 – 2.62 cm.wk‑1, 0.0031 – 0.1369 cm.wk‑1 and 0.0008 – 0.0831 cm.wk‑1 and 0.0 – 1.9 leaves.wk‑1 and 0.0 – 1.6 leaves.wk-1respectively for height, diameter and number of leaves. Data analysis showed that the growth of seedling height of Avicennia in the mixed structure was significantly affected by its diameter growth and the number of leaves of Avicennia in single structured was significantly affected by its diameter. While the height, diameter and number of leaves of R. mucronata both in mixed and single structured silvofishery ponds were independent to each other. This research concluded that mangrove seedling growth is varied among species and growth environment.

  10. Connector tube for a turbine rotor cooling circuit

    DOEpatents

    Li, Ming Cheng

    2003-06-24

    A tubular connector adapted to extend between two tubular components comprising a tubular body having an internal diameter, a first free end including an annular radial flange having a tapered surface adapted to engage a complementary seating surface on a first of the two tubular components, the internal diameter remaining constant through the first free end; and a second free end having an annular bulbous shape adapted to seat within a cylindrical end of a second of the two tubular components.

  11. Connector tube for a turbine rotor cooling circuit

    DOEpatents

    Li, Ming Cheng

    2002-01-01

    A tubular connector adapted to extend between two tubular components comprising a tubular body having an internal diameter, a first free end including an annular radial flange having a tapered surface adapted to engage a complementary seating surface on a first of the two tubular components, the internal diameter remaining constant through the first free end; and a second free end having an annular bulbous shape adapted to seat within a cylindrical end of a second of the two tubular components.

  12. X-ray optics made from thin plastic foils

    NASA Astrophysics Data System (ADS)

    Schnopper, H. W.; Barbera, M.; Ingram, R.; Silver, E.; Romaine, S.; Bandler, S.; Murray, S.; Christensen, F. E.; Hussain, A.; Collura, A.

    2000-10-01

    New design concepts and materials can be used to produce lightweight, thin foil approximations, to Wolter I and other X-ray optics. Structures are designed around a central hub and spacers that connect two (or three) spoked wheels. Figure defining, thin pins span the distance between the wheels. Thin, metal coated or multilayered, plastic foils can be formed into full cones, cylinders or spirals for X-ray telescopes or lenses. High resolution X-ray scattering data were obtained for single foils at Cu K (8 KeV). Multi-energy (0.28 - 8 KeV) data were obtained with a multichannel plate imager in a 17 m beam line with a point-to-point focusing, cylindrical X-ray lens with 14 shells. The largest shell has a diameter of 175 mm and a length of 100 mm. Typical images have a FWHM of 20 arcsec. The results indicate that a 60 cm diameter, 4.65 m focal length X-ray telescope can have an HPD of considerably less than 2 arcmin. This research is supported, in part by NASA Grant NAG5-5268, ONR Grant N00014-95-1-1248, and by institutional funding from the Smithsonian Astrophysical Observatory. The SAO multilayer facility receives support from NASA Grant NAG5-5095. This work made use of the MRSEC Shared Experimental Facilities at MIT supported by NSF Grant DMR94-00334.

  13. An in vitro comparison of tracheostomy tube cuffs

    PubMed Central

    Maguire, Seamus; Haury, Frances; Jew, Korinne

    2015-01-01

    Introduction The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT]) with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force. Methods Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O), instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site. Results The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05). The taper-shaped cuff also demonstrated a more even, lower pressure distribution along the lateral wall of the model trachea. The average air and fluid seal performance with the taper-shaped cuff was significantly improved, when compared to the cylindrical-shaped cuff, for each tube size tested (P<0.05). The insertion force for the taper-shaped cuff was ~40% less than that for the cylindrical-shaped cuff. Conclusion In a model trachea, the Shiley™ Flexible Adult tracheostomy tube with TaperGuard™ cuff, when compared to the Shiley™ Disposable Inner Cannula Tracheostomy tube with cylindrical cuff, exerted a lower average lateral wall pressure and a more evenly distributed pressure. In addition, it provided more effective fluid and air seals and required less force to insert. PMID:25960679

  14. Optical properties of carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Chen, Gugang

    This thesis addresses the optical properties of novel carbon filamentary nanomaterials: single-walled carbon nanotubes (SWNTs), double-walled carbon nanotubes (DWNTs), and SWNTs with interior C60 molecules ("peapods"). Optical reflectance spectra of bundled SWNTs are discussed in terms of their electronic energy band structure. An Effective Medium Model for a composite material was found to provide a reasonable description of the spectra. Furthermore, we have learned from optical absorption studies of DWNTs and C60-peapods that the host tube and the encapsulant interact weakly; small shifts in interband absorption structure were observed. Resonant Raman scattering studies on SWNTs synthesized via the HiPCO process show that the "zone-folding" approximation for phonons and electrons works reasonably well, even for small diameter (d < 1 nm) tubes. The energy of optical transitions between van Hove singularities in the electronic density of states computed from the "zone-folding" model (with gamma0 = 2.9 eV) agree well with the resonant conditions for Raman scattering. Small diameter tubes were found to exhibit additional sharp Raman bands in the frequency range 500-1200 cm-1 with an, as yet, undetermined origin. The Raman spectrum of a DWNT was found to be well described by a superposition of the Raman spectra expected for inner and outer tubes, i.e., no charge transfer occurs and the weak van der Waals (vdW) interaction between tubes does not have significant impact on the phonons. A ˜7 cm-1 downshift of the small diameter, inner-tube tangential mode frequency was observed, however, but attributed to a tube wall curvature effect, rather than the vdW interaction. Finally, we studied the chemical doping of DWNTs, where the dopant (Br anions) is chemically bound to the outside of the outer tube. The doped DWNT system is a model for a cylindrical molecular capacitor. We found experimentally that 90% of the positive charge resides on the outer tube, so that most of electric field on the inner tube is screened, i.e., we have observed a molecular Faraday cage effect. A self-consistent theoretical model in the tight-binding approximation with a classical electrostatic energy term is in good agreement with our experimental results.

  15. High-Temperature Helical-Tube Solar Receiver

    NASA Technical Reports Server (NTRS)

    Robertson, C. S., Jr.; Mccreight, L.

    1984-01-01

    Solar-thermal receiver used with circular parabolic concentrator to supply about 58 kW thermal power to Brayton engine or industrial process. Solar radiation focused into open end of cylindrical ceramic thermal inertial sleeve 8 in. in diameter that reradiates energy to helical heatexchanger tube surrounding sleeve.

  16. Wetting, meniscus structure, and capillary interactions of microspheres bound to a cylindrical liquid interface.

    PubMed

    Kim, Paul Y; Dinsmore, Anthony D; Hoagland, David A; Russell, Thomas P

    2018-03-14

    Wetting, meniscus structure, and capillary interactions for polystyrene microspheres deposited on constant curvature cylindrical liquid interfaces, constructed from nonvolatile ionic or oligomeric liquids, were studied by optical interferometry and optical microscopy. The liquid interface curvature resulted from the preferential wetting of finite width lines patterned onto planar silicon substrates. Key variables included sphere diameter, nominal (or average) contact angle, and deviatoric interfacial curvature. Menisci adopted the quadrupolar symmetry anticipated by theory, with interfacial deformation closely following predicted dependences on sphere diameter and nominal contact angle. Unexpectedly, the contact angle was not constant locally around the contact line, the nominal contact angle varied among seemingly identical spheres, and the maximum interface deviation did not follow the predicted dependence on deviatoric interfacial curvature. Instead, this deviation was up to an order-of-magnitude larger than predicted. Trajectories of neighboring microspheres visually manifested quadrupole-quadrupole interactions, eventually producing square sphere packings that foreshadow interfacial assembly as a potential route to hierarchical 2D particle structures.

  17. Microcrystalline diamond cylindrical resonators with quality-factor up to 0.5 million

    NASA Astrophysics Data System (ADS)

    Saito, Daisuke; Yang, Chen; Heidari, Amir; Najar, Hadi; Lin, Liwei; Horsley, David A.

    2016-02-01

    We demonstrate high quality-factor 1.5 mm diameter batch-fabricated microcrystalline diamond cylindrical resonators (CR) with quality-factors limited by thermoelastic damping (TED) and surface loss. Resonators were fabricated 2.6 and 5.3 μm thick in-situ boron-doped microcrystalline diamond films deposited using hot filament chemical vapor deposition. The quality-factor (Q) of as-fabricated CR's was found to increase with the resonator diameter and diamond thickness. Annealing the CRs at 700 °C in a nitrogen atmosphere led to a three-fold increase in Q, a result we attribute to thinning of the diamond layer via reaction with residual O2 in the annealing furnace. Post-anneal Q exceeding 0.5 million (528 000) was measured at the 19 kHz elliptical wineglass modes, producing a ring-down time of 8.9 s. A model for Q versus diamond thickness and resonance frequency is developed including the effects of TED and surface loss. Measured quality factors are shown to agree with the predictions of this model.

  18. Design and Construction of a Small Vacuum Furnace

    NASA Astrophysics Data System (ADS)

    Peawbang, P.; Thedsakhulwong, A.

    2017-09-01

    The purpose of this research is designed and constructed of a small vacuum furnace. A cylindrical graphite was chosen as the material of the furnace, the cylinder aluminium and copper sheets were employed to prevent the heat radiation that transfers from the furnace to the chamber wall. A rotary pump used, the pressure of graphite furnace can be pumped up to 30 mTorr and heated up to 700 °C driving by wire and the temperature of the chamber wall is relatively remained too low. In addition, heat loss obtained from the graphite furnace by conduction, convection, and radiation were analyzed. The dominating heat loss was found to be caused by the blackbody radiation, which can thus be used to estimate the relationship between graphite furnace temperature and the drive power needed. The cylindrical graphite furnace has an inner diameter of 44 mm, the outer diameter of 60 mm and 45 mm in height, the 355.5 W of power is needed to drive the furnace to 700 °C.

  19. Direct Cast U-6Nb – 2017 Progress on Cylindrical Castings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aikin, Jr., Robert M.

    2017-10-04

    This report describes work to further develop a sound technical basis and best practices for mold design and process parameters for the Direct Casting of U-6wt%Nb components. One major challenge to the production of U-6Nb components is the propensity for niobium segregation during casting and solidification. This is especially true for cylindrical castings where the vertical side walls allow flotation of Nb resulting in severe inverse macrosegregation. In this work, a small (120 mm diameter by 180 mm tall) and large cylinder (250 mm diameter by 310 mm tall) are examined with a focus on reducing, or eliminating, niobium segregation.more » It is demonstrated that counter gravity casting (top-to-bottom solidification) can be used to minimize segregation in the small cylinder. Attempts to counter gravity cast the large cylinder were unsuccessful, in large part due to size limitations of the current furnace. A path forward for casting of the large cylinders is discussed.« less

  20. Experimental study on acoustic subwavelength imaging of holey-structured metamaterials by resonant tunneling.

    PubMed

    Su, Haijing; Zhou, Xiaoming; Xu, Xianchen; Hu, Gengkai

    2014-04-01

    A holey-structured metamaterial is proposed for near-field acoustic imaging beyond the diffraction limit. The structured lens consists of a rigid slab perforated with an array of cylindrical holes with periodically modulated diameters. Based on the effective medium approach, the structured lens is characterized by multilayered metamaterials with anisotropic dynamic mass, and an analytic model is proposed to evaluate the transmission properties of incident evanescent waves. The condition is derived for the resonant tunneling, by which evanescent waves can completely transmit through the structured lens without decaying. As an advantage of the proposed lens, the imaging frequency can be modified by the diameter modulation of internal holes without the change of the lens thickness in contrast to the lens due to the Fabry-Pérot resonant mechanism. In this experiment, the lens is assembled by aluminum plates drilled with cylindrical holes. The imaging experiment demonstrates that the designed lens can clearly distinguish two sources separated in the distance below the diffraction limit at the tunneling frequency.

  1. Jamming of Cylindrical Grains in Featureless Vertical Channels

    NASA Astrophysics Data System (ADS)

    Baxter, G. William; Barr, Nicholas; Weible, Seth; Friedl, Nicholas

    2013-03-01

    We study jamming of low aspect-ratio cylindrical Delrin grains falling through a featureless vertical channel. With a grain height less than the grain diameter, these grains resemble aspirin tablets, poker chips, or coins. Unidisperse grains are allowed to fall under the influence of gravity through a uniform channel of square cross-section where the channel width is greater than the grain size and constant along the length of the channel. Channel widths are chosen so that no combination of grain heights and diameters is equal to the channel width. Collections of grains sometimes form jams, stable structures in which the grains are supported by the channel walls and not by grains or walls beneath them. The probability of a jam occurring and the jam's strength are influenced by the grain dimensions and channel width. We will present experimental measurements of the jamming probability and jam strength and discuss the relationship of these results to other experiments and theories. Supported by an Undergraduate Research Grant from Penn State Erie, The Behrend College

  2. Economics of ingot slicing with an internal diameter saw for low-cost solar cells

    NASA Technical Reports Server (NTRS)

    Daud, T.; Liu, J. K.; Fiegl, G.

    1981-01-01

    Slicing of silicon ingots using diamond impregnated internal diameter blade saws has been a standard technology of the semiconductor industry. This paper describes work on improvements to this technology for 10 cm diameter ingot slicing. Ingot rotation, dynamic blade edge control with feedback, mechanized blade dressing and development of thinner blades are the approaches tried. A comparison of the results for wafering with and without ingot rotation is also made. A sensitivity analysis of the major cost elements in wafering is performed for 10 cm diameter ingot and extended to the 15 cm diameter ingot case. Various parameter values such as machine cost, feed rate and consumable materials cost are identified both for single and multiple ingot slicing.

  3. Launch and Functional Considerations Guiding the Scaling and Design of Rigid Inflatable Habitat Modules

    NASA Astrophysics Data System (ADS)

    Bell, L.

    2002-01-01

    The Sasakawa International Center for Space Architecture (SICSA) has a long history of projects that involve design of space structures, including habitats for low-Earth orbit (LEO) and planetary applications. Most of these facilities and component systems are planned to comply with size, geometry and mass restrictions imposed by the Space Shuttle Orbiter's payload and lift/landing abort restrictions. These constraints limit launch elements to approximately 15 ft. diameter, 40 ft. long cylindrical dimensions weighing no more than approximately 25 metric tons. It is clear that future success of commercial space programs such as tourism will hinge upon the availability of bigger and more efficient Earth to LEO launch vehicles which can greatly reduce transportation and operational costs. This will enable development and utilization of larger habitat modules and other infrastructure elements which can be deployed with fewer launches and on-orbit assembly procedures. The sizing of these new heavy lift launchers should be scaled to optimize habitat functionality and efficiency, just as the habitat designs must consider optimization of launch vehicle economy. SICSA's planning studies address these vehicle and habitat optimization priorities as parallel and interdependent considerations. The allowable diameter of habitat modules established by launch vehicle capacity dictates functionally acceptable internal configuration options. Analyses of these options relative to practical dimensions for Earth-to-orbit launch vehicle scaling were conducted for two general schemes. The "bologna slice" configuration stacks the floors within a predominately cylindrical or spherical envelope, producing circular areas. The "banana split" approach divides a cylindrical module longitudinally, creating floors that are generally rectangular in shape. The assessments established minimum sizes for reasonable utility and efficiency. The bologna slice option. This configuration is only acceptable for modules with diameters of approximately 45 ft. or more. Smaller dimensions will severely limit maximum sight lines, creating claustrophobic conditions. Equipment racks and other elements typically located around internal parameters will further reduce open areas, and vertical circulation access ways between floor levels will diminish usable space even more. However this scheme can work very well for larger diameter habitats, particularly for surface applications where a relatively wide-based/low height module is to be landed vertically. The banana split option. A longitudinal floor orientation can serve very satisfactorily for modules with diameters of 15 ft. or more. Unlike the bologna slice's circular floors, the rectangular spaces offer considerable versatility to accommodate diverse equipment and functional arrangements. Modules smaller than 15 ft. in diameter (the International Space Station standard) will be incompatible with efficient equipment rack design and layouts due to tight-radius wall curvatures. Beyond the 15 ft. diameters, it is logical to scale the modules at dimensional increments based upon the number of desired floors, allowing approximately 8-9 ft. of height/level. Current SICSA Mars mission planning advocates development of new launchers with payload accommodations for 45 ft. diameter, 200 metric ton cargo elements. This large booster will offer launch economies along with habitat scaling advantages. Launch system design efficiencies are influenced by the amount of functional drag that results as the vehicle passes through the Earth's atmosphere. These drag losses are subject to a "cubed-squared law". As the launchcraft's external dimensions increase, its surface area increases with the square of the dimension, while the volume increases with the cube. Since drag is a function of surface, not volume, increasing the vehicle size will reduce proportional drag losses. For this reason, the huge Saturn V Moon rocket experienced relatively low drag. Module pressure envelope geometries also influence internal layout versatility and functionality. SICSA examined cylindrical and spherical envelope approaches for habitat module application, exploring special advantages and disadvantages each presented. The 45 ft. diameter sphere constrained functional volumes and layouts around the upper level perimeter. A modified scheme was selected which reshaped and expanded the height of that area. SICSA's final plan proposes 45 ft. diameter modules of modified spherical form.

  4. Bias of cylinder diameter estimation from ground-based laser scanners with different beam widths: A simulation study

    NASA Astrophysics Data System (ADS)

    Forsman, Mona; Börlin, Niclas; Olofsson, Kenneth; Reese, Heather; Holmgren, Johan

    2018-01-01

    In this study we have investigated why diameters of tree stems, which are approximately cylindrical, are often overestimated by mobile laser scanning. This paper analyzes the physical processes when using ground-based laser scanning that may contribute to a bias when estimating cylinder diameters using circle-fit methods. A laser scanner simulator was implemented and used to evaluate various properties, such as distance, cylinder diameter, and beam width of a laser scanner-cylinder system to find critical conditions. The simulation results suggest that a positive bias of the diameter estimation is expected. Furthermore, the bias follows a quadratic function of one parameter - the relative footprint, i.e., the fraction of the cylinder width illuminated by the laser beam. The quadratic signature opens up a possibility to construct a compensation model for the bias.

  5. Wavelength dependence of the apparent diameter of retinal blood vessels

    NASA Astrophysics Data System (ADS)

    Park, Robert; Twietmeyer, Karen; Chipman, Russell; Beaudry, Neil; Salyer, David

    2005-04-01

    Imaging of retinal blood vessels may assist in the diagnosis and monitoring of diseases such as glaucoma, diabetic retinopathy, and hypertension. However, close examination reveals that the contrast and apparent diameter of vessels are dependent on the wavelength of the illuminating light. In this study multispectral images of large arteries and veins within enucleated swine eyes are obtained with a modified fundus camera by use of intravitreal illumination. The diameters of selected vessels are measured as a function of wavelength by cross-sectional analysis. A fixed scale with spectrally independent dimension is placed above the retina to isolate the chromatic effects of the imaging system and eye. Significant apparent differences between arterial and venous diameters are found, with larger diameters observed at shorter wavelengths. These differences are due primarily to spectral absorption in the cylindrical blood column.

  6. Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: is there a relationship? An in vitro study.

    PubMed

    Trisi, Paolo; De Benedittis, Simona; Perfetti, Giorgio; Berardi, Davide

    2011-05-01

    Protocols of immediate loading have been reported in several studies. It has also been demonstrated that the cause of failure of immediate loaded implants is due to the micromotion on the bone-implant interface induced by immediate loading. There should be a minimum gap between the implant and the peri-implant bone, without micromotions occurring above a definite threshold risk as they induce bone resorption and fibrosis around the implant. Measurement of the torque necessary to insert an implant in the bone is a parameter for measuring initial stability. The higher the implant insertion torque, the higher the initial stability attained. The aim of this study was to evaluate in vitro the correlation between the micromotion of cylindric screw implants ad modum Branemark and the insertion torque in bone of different densities. The test was carried out on 2 × 2 cm samples of fresh bovine bone of three different densities: hard (H), medium (M) and soft (S). One hundred and fifty hexa implants ad modum Branemark were used, 3.75 mm in diameter and 9 mm long. To screw in the implants, a customized manual key was used, controlled digitally to evaluate the peak insertion torques. Ten implants were prepared for each torque (20, 35, 45, 70 and 100 N/cm). The bone sample was then fixed on a loading device, which allowed evaluating the micromotion. On each sample, we applied a 25 N horizontal force. The results indicate that the peak insertion torque and the implant micromotion are statistically correlated, and statistically significant differences in H and M bone were found compared with S bone. In S bone, we noted a micromotion significantly higher than the risk threshold, and it was not possible to reach peak insertion torque above 35 N/cm. In H and M bone, the micromotion is below the threshold of all insertion torques. Increasing the peak insertion torque, we can reduce the extent of the micromotion between the implant and the bone when submitted to lateral forces in vitro. In soft bone, the micromotion was always high; hence, immediate loading of implants in low-density bone should be evaluated with care. © 2010 John Wiley & Sons A/S.

  7. Axially uniform resonant cavity modes for potential use in electron paramagnetic resonance spectroscopy

    NASA Astrophysics Data System (ADS)

    Mett, Richard R.; Froncisz, Wojciech; Hyde, James S.

    2001-11-01

    This article is concerned with cylindrical transverse electric TE011 and rectangular TE102 microwave cavity resonators commonly used in electron paramagnetic resonance (EPR) spectroscopy. In the cylindrical mode geometry considered here, the sample is along the z axis of the cylinder, dielectric disks of 1/4 wavelength thickness are placed at each end wall, and the diameter of the cylinder is set at the cutoff condition for propagation of microwave energy in a cylindrical waveguide at the desired microwave frequency. The microwave magnetic field is exactly uniform along the sample in the region between the dielectric disks and the resonant frequency is independent of the length of the cylinder without limit. The rectangular TE102 geometry is analogous, but here the microwave magnetic field is exactly uniform in a plane. A uniform microwave field along a line sample is highly advantageous in EPR spectroscopy compared with the usual sinusoidal variation, and these geometries are called "uniform field" modes. Extensive theoretical analysis as well as finite element calculation of field patterns are presented. The perturbation of field patterns caused by sample insertion as functions of the overall length of the resonator and diameter of the sample is analyzed. The article is intended to provide a basis for design of practical structures in the range of 10 to 100 GHz.

  8. Analysis of lunar regolith thermal energy storage

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony J.

    1991-01-01

    The concept of using lunar regolith as a thermal energy storage medium was evaluated. The concept was examined by mathematically modeling the absorption and transfer of heat by the lunar regolith. Regolith thermal and physical properties were established through various sources as functions of temperature. Two cases were considered: a semi-infinite, constant temperature, cylindrical heat source embedded in a continuum of lunar regolith and a spherically shaped molten zone of lunar regolith set with an initial temperature profile. The cylindrical analysis was performed in order to examine the amount of energy which can be stored in the regolith during the day. At night, the cylinder acted as a perfect insulator. This cycling was performed until a steady state situation was reached in the surrounding regolith. It was determined that a cycling steady state occurs after approximately 15 day/night cycles. Results were obtained for cylinders of various diameters. The spherical molten zone analysis was performed to establish the amount of thermal energy, within the regolith, necessary to maintain some molten material throughout a nighttime period. This surrounding temperature profile was modeled after the cycling steady state temperature profile established by the cylindrical analysis. It was determined that a molten sphere diameter of 4.76 m is needed to maintain a core temperature near the low end of the melting temperature range throughout one nighttime period.

  9. Explosion-Induced Implosions of Cylindrical Shell Structures

    NASA Astrophysics Data System (ADS)

    Ikeda, C. M.; Duncan, J. H.

    2010-11-01

    An experimental study of the explosion-induced implosion of cylindrical shell structures in a high-pressure water environment was performed. The shell structures are filled with air at atmospheric pressure and are placed in a large water-filled pressure vessel. The vessel is then pressurized to various levels P∞=αPc, where Pc is the natural implosion pressure of the model and α is a factor that ranges from 0.1 to 0.9. An explosive is then set off at various standoff distances, d, from the model center line, where d varies from R to 10R and R is the maximum radius of the explosion bubble. High-speed photography (27,000 fps) was used to observe the explosion and resulting shell structure implosion. High-frequency underwater blast sensors recorded dynamic pressure waves at 6 positions. The cylindrical models were made from aluminum (diameter D = 39.1 mm, wall thickness t = 0.89 mm, length L = 240 mm) and brass (D = 16.7 mm, t = 0.36 mm, L=152 mm) tubes. The pressure records are interpreted in light of the high-speed movies. It is found that the implosion is induced by two mechanisms: the shockwave generated by the explosion and the jet formed during the explosion-bubble collapse. Whether an implosion is caused by the shockwave or the jet depends on the maximum bubble diameter and the standoff distance.

  10. Cylindrical micelles of a POSS amphiphilic dendrimer as nano-reactors for polymerization.

    PubMed

    Weng, Jing-Ting; Yeh, Tso-Fan; Samuel, Ashok Zachariah; Huang, Yi-Fan; Sie, Jyun-Hao; Wu, Kuan-Yi; Peng, Chi-How; Hamaguchi, Hiro-O; Wang, Chien-Lung

    2018-02-15

    A low generation amphiphilic dendrimer, POSS-AD, which has a POSS core and eight amphiphilic arms, was synthesized and used as a nano-reactor to produce well-defined polymer nano-cylinders. Confirmed by small-angle X-ray scattering (SAXS), Raman and NMR spectrometry, monodispersed cylindrical micelles that contain a hydrophilic cavity with a diameter of 2.09 nm and a length of 4.26 nm were produced via co-assembling POSS-AD with hydrophilic liquids, such as H 2 O and HEMA in hydrophobic solvents. Taking the HEMA/POSS-AD cylindrical micelles as nano-reactors, polymerization of HEMA within the micelles results in polymer nano-cylinders (POSS-ADNPs) with a diameter of 2.24 nm and a length of 5.02 nm. The study confirmed that despite the inability to maintain specific shape in solution, low generation dendrimers form well-defined nano-containers or nano-reactors, which relies on co-assembling with hydrophilic guest molecules. These nano-reactors are robust enough to maintain their shape during the polymerization of the guest molecules. Polymer nano-cylinders with dimensions less than 10 nm can thus be produced from the HEMA/POSS-AD micelles. Since the chemical structure of low-generation dendrimers and the contents of the co-assembled nano-reactors can be easily adjusted, the concept holds the potential for the further developments of low-generation amphiphilic dendrimers.

  11. CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Xinhua; Zhang, Da; Liu, Bob, E-mail: bliu7@mgh.harvard.edu

    2015-06-15

    Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D{sub L}(0) and its rise-to-the-equilibrium curve H(L) = D{sub L}(0)/D{sub eq} from computed tomography (CT) scanning, where D{sub eq} is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessedmore » H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm{sup 3} thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E{sub in}/E or E{sub out}/E) on the phantom central and peripheral axes, where E = LD{sub eq} was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose ratios changed with beam aperture and phantom axis but were insensitive to tube voltage. H(L) was insensitive to tube voltage and CT scanner model. As phantom diameter increased from 6 to 55 cm, E{sub in}/E generally decreased but asymptotically approached constant levels on the peripheral axes of large phantoms. The curve of E{sub in}/E versus scan length was almost identical to that of H(L). Similarly, E{sub out}/E increased with scan length and asymptotically approached the equilibrium for large scan lengths. E{sub out}/D{sub eq} was much less than the equilibrium length L{sub eq} where H(L) = 0.98, even with scan lengths much larger than L{sub eq}. Conclusions: The polyethylene phantom designed by ICRU Report No. 87 Committee and AAPM Task Group 200 is adequately long for assessing the midpoint dose and its equilibration in CT scanning. The short-to-long phantom dose ratios and the H(L) data provided in this paper allow easy evaluations of the midpoint dose, longitudinal dose distribution, and energy absorption in polyethylene phantoms. The results of dose equilibration and energy absorption presented herein may be insightful for the clinical CT scans with various subject sizes and scan lengths.« less

  12. Characterization of the SAR-distribution of the Sigma-60 applicator for regional hyperthermia using a Schottky diode sheet.

    PubMed

    Van Rhoon, G C; Van Der Heuvel, D J; Ameziane, A; Rietveld, P J M; Volenec, K; Van Der Zee, J

    2003-01-01

    Characterization of the performance of an hyperthermia applicator by phantom experiments is an essential aspect of quality assurance in hyperthermia. The objective of this study was to quantitatively characterize the energy distribution of the Sigma-60 applicator of the BSD2000 phased array system operated within the normal frequency range of 70-120 MHz. Additionally, the accuracy of the flexible Schottky diode sheet to measure E-field distributions was assessed. The flexible Schottky diode sheet (SDS) consists of 64 diodes mounted on a flexible 125 microm thick polyester foil. The diodes are connected through high resistive wires to the electronic readout system. With the SDS E-field distributions were measured with a resolution of 2.5 x 2.5 cm in a cylindrical phantom, diameter of 26 cm and filled with saline water (2 g/l). The phantom was positioned symmetrically in the Sigma-60 applicator. RF-power was applied to the 4-channel applicator with increasing steps from 25W to a total output of 400 W. The complete system to measure the E-field distribution worked fine and reliably within the Sigma-60 applicator. The E-field distributions measured showed that the longitudinal length of the E-field distribution is more or less constant, e.g. 21-19 cm, over the frequency range of 70-120 MHz, respectively. As expected, the radial E-field distributions show a better focusing towards the centre of the phantom for higher frequencies, e.g. from 15.3-8.7 cm diameter for 70-120 MHz, respectively. The focusing target could be moved accurately from the left to the right side of the phantom. Further it was found that the sensitivity variation of nine diodes located at the centre of the phantom was very small, e.g. < 3% over the whole frequency range. The SAR distributions of the Sigma-60 applicator are in good agreement with theoretically expected values. The flexible Schottky diode sheet proves to be an excellent tool to make accurate, quantitative measurements of E-field distributions at low (25 W) and medium (400 W) power levels. An important feature of the SDS is that it enables one to significantly improve quantitative quality assurance procedures and to start quantitative comparisons of the performance of the different deep hyperthermia systems used by the various hyperthermia groups.

  13. Measurement of bone mineral density in the tunnel regions for anterior cruciate ligament reconstruction by dual-energy X-ray absorptiometry, computed tomography scan, and the immersion technique based on Archimedes' principle.

    PubMed

    Tie, Kai; Wang, Hua; Wang, Xin; Chen, Liaobin

    2012-10-01

    To determine, for anterior cruciate ligament (ACL) reconstruction, whether the bone mineral density (BMD) of the femoral tunnel was higher than that of the tibial tunnel, to provide objective evidence for choosing the appropriate diameter of interference screws. Two groups were enrolled. One group comprised 30 normal volunteers, and the other comprised 9 patients with ACL rupture. Dual-energy X-ray absorptiometry was used to measure the BMD of the femoral and tibial tunnel regions of the volunteers' right knees by choosing a circular area covering the screw fixation region. The knees were also scanned by spiral computed tomography (CT), and the 3-dimensional reconstruction technique was used to determine the circular sections passing through the longitudinal axis of the femoral and tibial tunnels. Grayscale CT values of the cross-sectional area were measured. Cylindrical cancellous bone blocks were removed from the femoral and tibial tunnels during the ACL reconstruction for the patients. The volumetric BMD of the bone blocks was measured using a standardized immersion technique according to Archimedes' principle. As measured by dual-energy X-ray absorptiometry, the BMD of the femoral and tibial tunnel regions was 1.162 ± 0.034 g/cm(2) and 0.814 ± 0.038 g/cm(2), respectively (P < .01). The CT value of the femoral tunnel region was 211.7 ± 11.5 Hounsfield units, and the value of the tibial tunnel region was 104.9 ± 7.4 Hounsfield units (P < .01). The volumetric BMD of the bone block from the femoral tunnel (2.80 ± 0.88 g/cm(3)) was higher than the value from the tibial tunnel (1.88 ± 0.59 g/cm(3)) (P < .01). Comparing the data between male and female patients, we found no significant difference in both femoral and tibial tunnel regions. For ACL reconstruction, the BMD of the femoral tunnel is higher than that of the tibial tunnel. This implies that a proportionally larger-diameter interference screw should be used for fixation in the proximal tibia than that used for fixation in the distal femur. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. Method for grinding precision components

    DOEpatents

    Ramanath, Srinivasan; Kuo, Shih Yee; Williston, William H.; Buljan, Sergej-Tomislav

    2000-01-01

    A method for precision cylindrical grinding of hard brittle materials, such as ceramics or glass and composites comprising ceramics or glass, provides material removal rates as high as 19-380 cm.sup.3 /min/cm. The abrasive tools used in the method comprise a strong, light weight wheel core bonded to a continuous rim of abrasive segments containing superabrasive grain in a dense metal bond matrix.

  15. Minimization of the hole overcut and cylindricity errors during rotary ultrasonic drilling of Ti-6Al-4V

    NASA Astrophysics Data System (ADS)

    Nasr, M.; Anwar, S.; El-Tamimi, A.; Pervaiz, S.

    2018-04-01

    Titanium and its alloys e.g. Ti6Al4V have widespread applications in aerospace, automotive and medical industry. At the same time titanium and its alloys are regarded as difficult to machine materials due to their high strength and low thermal conductivity. Significant efforts have been dispensed to improve the accuracy of the machining processes for Ti6Al4V. The current study present the use of the rotary ultrasonic drilling (RUD) process for machining high quality holes in Ti6Al4V. The study takes into account the effects of the main RUD input parameters including spindle speed, ultrasonic power, feed rate and tool diameter on the key output responses related to the accuracy of the drilled holes including cylindricity and overcut errors. Analysis of variance (ANOVA) was employed to study the influence of the input parameters on cylindricity and overcut error. Later, regression models were developed to find the optimal set of input parameters to minimize the cylindricity and overcut errors.

  16. Design Considerations of Polishing Lap for Computer-Controlled Cylindrical Polishing Process

    NASA Technical Reports Server (NTRS)

    Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    The future X-ray observatory missions, such as International X-ray Observatory, require grazing incidence replicated optics of extremely large collecting area (3 m2) in combination with angular resolution of less than 5 arcsec half-power diameter. The resolution of a mirror shell depends ultimately on the quality of the cylindrical mandrels from which they are being replicated. Mid-spatial-frequency axial figure error is a dominant contributor in the error budget of the mandrel. This paper presents our efforts to develop a deterministic cylindrical polishing process in order to keep the mid-spatial-frequency axial figure errors to a minimum. Simulation studies have been performed to optimize the operational parameters as well as the polishing lap configuration. Furthermore, depending upon the surface error profile, a model for localized polishing based on dwell time approach is developed. Using the inputs from the mathematical model, a mandrel, having conical approximated Wolter-1 geometry, has been polished on a newly developed computer-controlled cylindrical polishing machine. We report our first experimental results and discuss plans for further improvements in the polishing process.

  17. Optimal condition for employing an axicon-generated Bessel beam to fabricate cylindrical microlens arrays

    NASA Astrophysics Data System (ADS)

    Luo, Zhi; Yin, Kai; Dong, Xinran; Duan, Ji’an

    2018-05-01

    A numerical algorithm, modelling the transformation from a Gaussian beam to a Bessel beam, is presented for the purpose to study the optimal condition for employing an axicon-generated Bessel beam to fabricate cylindrical microlens arrays (CMLAs). By applying the numerical algorithm to simulate the spatial intensity distribution behind the axicon under different defects of a rotund-apex and different diameter ratios of an incident beam to the axicon, we find that the diffraction effects formed by the axicon edge can be almost eliminated when the diameter ratio is less than 1:2, but the spatial intensity distribution is disturbed dramatically even a few tens of microns deviation of the apex, especially for the front part of the axicon-generated Bessel beam. Fortunately, the lateral intensity profile in the rear part still maintains a desirable Bessel curve. Therefore, the rear part of the Bessel area and the less than 1:2 diameter ratio are the optimal choice for employing an axicon-generated Bessel beam to implement surface microstructures fabrication. Furthermore, by applying the optimal conditions to direct writing microstructures on fused silica with a femtosecond (fs) laser, a large area close-packed CMLA is fabricated. The CMLA presents high quality and uniformity and its optical performance is also demonstrated.

  18. Structure and Dynamics of Polymers in Cylindrical Nanoconfinement: A Molecular Dynamics Study

    NASA Astrophysics Data System (ADS)

    Pressly, James; Riggleman, Robert; Winey, Karen

    The structure and dynamics of polymers under nanoconfinement is critical for understanding how polymers behave in applications from hydraulic fracking to fabricating integrated circuits. We previously used simulations to explore the effect of the diameter of cylindrical pores (d = 10-40 σ, where σ is the unit length in reduced units) on polymer end-to-end distance (Ree,perp, Ree,par) , entanglement density, melt diffusion coefficient (D), and local relaxation time (τperp, τpar) at fixed polymer chain length (N = 350). These studies found D, Ree,par, and τperp increased with increasing confinement while entanglement density, Ree,perp, and τpar decreased. Experiments also found that D increased but to a lesser extent. Here, we examine the molecular weight dependence of these properties using N = 25, 50, 100, 200, 350, and 500 confined to pores of diameter 14 σ to examine a range of confinements. Our preliminary results show that as N increases D and Ree,par, increase as well, relative to the unconfined state, while entanglement density and Ree,perp decrease, consistent with our previous work. Interestingly, τ is shown to be independent of chain length indicating the impact of confinement imposed by reducing pore diameter is distinct from that imposed by increasing chain length.

  19. CROSS-DISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Depletion interactions in a cylindric pipeline

    NASA Astrophysics Data System (ADS)

    Huang, Li-Xin; Gao, Hai-Xia; Li, Chun-Shu; Xiao, Chang-Ming

    2009-08-01

    In a colloidal system confined by a small cylindric pipeline, the depletion interaction between two large spheres is different to the system confined by two plates, and the influence on depletion interaction from the pipeline is related to both the size and shape of it. In this paper, the depletion interactions in the systems confined by pipelines of different sizes or different shapes are studied by Monte Carlo simulations. The numerical results show that the influence on depletion force from the cylindric pipeline is stronger than that from two parallel plates, and the depletion force will be strengthened when the diameter of the cylinder is decreased. In addition, we also find that the depletion interaction is rather affected if the shape change of the pipeline is slightly changed, and the influence on depletion force from the shape change is stronger than that from the size change.

  20. Procedure for detecting underground utilities with specific shape

    NASA Astrophysics Data System (ADS)

    Ristic, Aleksandar; Vrtunski, Milan; Govedarica, Miro; Bugarinovic, Zeljko

    2016-04-01

    Nowadays GPR technology is acknowledged as a reliable, fast, non-destructive remote sensing technology whose area of applications is wider every day. One of its most common applications is underground utility detection. Not only it is possible to detect the utility in the field, but using certain algorithms utilities which haven't been detected in the field can be detected in radargrams. There is a number of procedures for automated detection of utility in the radargrams. Further, there are procedures that can estimate certain parameters such as propagation velocity, diameter or even characteristics of the material. However, the majority of these procedures is designed to detect cylindrical shape utilities, which, in a radargram, are represented with hyperbolic reflection. According to geometry of hyperbola, utility parameters can be estimated. In this paper we present a procedure that is designed to estimate characteristics of non-cylindrical utilities. It is worth mentioning that these utilities are not so rare. Some underground tanks and sewage collectors are among them. Heat line is consisted of two insulated pipes of the same diameter, often placed in a concrete channel and covered with plates made from reinforced concrete. Therefore, it can be considered as non-cylindrical utility and such structure has characteristic signature in a radargram. The main idea of the proposed procedure is to detect this signature, and then, based on standardized parameters for the heat lines, to estimate the diameter of the pipes. The proposed procedure is based on artificial neural network. As a training set we made a number of radargrams collected on different locations which contain heat lines of various dimensions. Pipe diameters were in a range from 65 to 250 mm. 400MHz antenna was used since the depth hasn't exceeded 2m. After the network is trained it is validated using radargrams that haven't been used in the training set. Further tests were done with radargrams that contained none, one or several heat lines. Experiments showed that it is possible to automatically detect heating lines in a radargram and later, based on detection results, to estimate the diameter of the pipes using standard heat line dimensions. This paper is a contribution to the 2016 EGU GA Session GI3.1 "Civil Engineering Applications of Ground Penetrating Radar," organized by the COST Action TU1208

  1. Theoretical comparison of two interstitial ultrasound applicators designed to induce cylindrical zones of tissue ablation.

    PubMed

    Lafon, C; Chavrier, F; Prat, F; Chapelon, J Y; Cathignol, D

    1999-05-01

    Although interstitial techniques are invasive, they are still the first-line therapeutic modalities for certain types of tumour. They are mainly relevant to tumours that are either inoperable or located so deep that access is complicated. Of the various types of radiation that can be delivered by the interstitial route, ultrasound is the most suitable for deep heating. The study compares the efficacy of two types of applicator with respect to their ability to induce cylindrical zones of coagulation necrosis. The transducer of the first applicator is tubular, whereas the second is plane and can rotate around its axis. Both have an external diameter of 4 mm, are fitted with surface cooling systems and operate at 10.7 MHz and 14 W.cm-2. Comparison involves mathematical modelling of ablated tissue in the targeted area by resolving the bioheat transfer equation (BHTE) using an algorithm based on finite differences. The BHTE gives a temperature value from which the thermal dose can be determined. It is shown that tissue ablation by tubular transducers is slow, and, in consequence, perfusion disturbs the heating pattern: in vivo, irradiation with a tubular transducer lasting 1081 s would be required to ablate a tissue mass with a radius of 8 mm. The corresponding period using a rotating plane transducer with 20 firing angles is only 618 s. The mean exposure time of each shot lasts 31 +/- 7 s. Therefore perfusion would have much less impact in the case of therapy administered using a plane transducer than that using a tubular one.

  2. An inverted cylindrical sputter magnetron as metal vapor supply for electron cyclotron resonance ion sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weichsel, T., E-mail: tim.weichsel@fep.fraunhofer.de; Hartung, U.; Kopte, T.

    2014-05-15

    An inverted cylindrical sputter magnetron device has been developed. The magnetron is acting as a metal vapor supply for an electron cyclotron resonance (ECR) ion source. FEM simulation of magnetic flux density was used to ensure that there is no critical interaction between both magnetic fields of magnetron and ECR ion source. Spatially resolved double Langmuir probe and optical emission spectroscopy measurements show an increase in electron density by one order of magnitude from 1 × 10{sup 10} cm{sup −3} to 1 × 10{sup 11} cm{sup −3}, when the magnetron plasma is exposed to the magnetic mirror field of themore » ECR ion source. Electron density enhancement is also indicated by magnetron plasma emission photography with a CCD camera. Furthermore, photographs visualize the formation of a localized loss-cone - area, when the magnetron is operated at magnetic mirror field conditions. The inverted cylindrical magnetron supplies a metal atom load rate of R > 1 × 10{sup 18} atoms/s for aluminum, which meets the demand for the production of a milliampere Al{sup +} ion beam.« less

  3. Development and Optimization of a Dedicated, Hybrid Dual-Modality SPECT-CmT System for Improved Breast Lesion Diagnosis

    DTIC Science & Technology

    2009-01-01

    breast are radiotracer uptake by heart and liver. Glandular Tissue Implant Biopsy Clip Streak Artifact Adipose Tissue FIGURE 10: CmT reconstructed... adipose tissue and implants. The cylindrical artifact is due to the offset geometry (further explanation in Task 2(a)). The second patient was...and Image Reconstruction Our emission tomography system is composed of a compact 16x20cm2 field of view cadmium zinc telluride (CZT) LumaGEM

  4. Masses of Fluid for Cylindrical Tanks in Rock With Partial Uplift of Bottom Plate

    PubMed Central

    Taniguchi, Tomoyo; Katayama, Yukihiro

    2016-01-01

    This study proposes the use of a slice model consisting of a set of thin rectangular tanks for evaluating the masses of fluid contributing to the rocking motion of cylindrical tanks; the effective mass of fluid for rocking motion, that for rocking–bulging interaction, effective moment inertia of fluid for rocking motion and its centroid. They are mathematically or numerically quantified, normalized, tabulated, and depicted as functions of the aspect of tanks for different values of the ratio of the uplift width of the tank bottom plate to the diameter of tank for the designer's convenience. PMID:27303110

  5. Effect of multiply charged ions on the performance and beam characteristics in annular and cylindrical type Hall thruster plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Holak; Lim, Youbong; Choe, Wonho, E-mail: wchoe@kaist.ac.kr

    2014-10-06

    Plasma plume and thruster performance characteristics associated with multiply charged ions in a cylindrical type Hall thruster (CHT) and an annular type Hall thruster are compared under identical conditions such as channel diameter, channel depth, propellant mass flow rate. A high propellant utilization in a CHT is caused by a high ionization rate, which brings about large multiply charged ions. Ion currents and utilizations are much different due to the presence of multiply charged ions. A high multiply charged ion fraction and a high ionization rate in the CHT result in a higher specific impulse, thrust, and discharge current.

  6. Timing Characterization of Helium-4 Fast Neutron Detector with EJ-309 Organic Liquid Scintillator

    NASA Astrophysics Data System (ADS)

    Liang, Yinong; Zhu, Ting; Enqvist, Andreas

    2018-01-01

    Recently, the Helium-4 gas fast neutron scintillation detectors is being used in time-sensitive measurements, such time-of-flight and multiplicity counting. In this paper, a set of time aligned signals was acquired in a coincidence measurement using the Helium-4 gas detectors and EJ-309 liquid scintillators. The high-speed digitizer system is implanted with a trigger moving average window (MAW) unit combing with its constant fraction discriminator (CFD) feature. It can calculate a "time offset" to the timestamp value to get a higher resolution timestamp (up to 50 ps), which is better than the digitizer's time resolution (4 ns) [1]. The digitized waveforms were saved to the computer hard drive and post processed with digital analysis code to determine the difference of their arrival times. The full-width at half-maximum (FWHM) of the Gaussian fit was used as to examine the resolution. For the cascade decay of Cobalt-60 (1.17 and 1.33 MeV), the first version of the Helium-4 detector with two Hamamatsu R580 photomultipliers (PMT) installed at either end of the cylindrical gas chamber (20 cm in length and 4.4 cm in diameter) has a time resolution which is about 3.139 ns FWHM. With improved knowledge of the timing performance, the Helium-4 scintillation detectors are excellent for neutron energy spectrometry applications requiring high temporal and energy resolutions.

  7. Mechanical properties of concrete containing a high volume of tire-rubber particles.

    PubMed

    Khaloo, Ali R; Dehestani, M; Rahmatabadi, P

    2008-12-01

    Due to the increasingly serious environmental problems presented by waste tires, the feasibility of using elastic and flexible tire-rubber particles as aggregate in concrete is investigated in this study. Tire-rubber particles composed of tire chips, crumb rubber, and a combination of tire chips and crumb rubber, were used to replace mineral aggregates in concrete. These particles were used to replace 12.5%, 25%, 37.5%, and 50% of the total mineral aggregate's volume in concrete. Cylindrical shape concrete specimens 15 cm in diameter and 30 cm in height were fabricated and cured. The fresh rubberized concrete exhibited lower unit weight and acceptable workability compared to plain concrete. The results of a uniaxial compressive strain control test conducted on hardened concrete specimens indicate large reductions in the strength and tangential modulus of elasticity. A significant decrease in the brittle behavior of concrete with increasing rubber content is also demonstrated using nonlinearity indices. The maximum toughness index, indicating the post failure strength of concrete, occurs in concretes with 25% rubber content. Unlike plain concrete, the failure state in rubberized concrete occurs gently and uniformly, and does not cause any separation in the specimen. Crack width and its propagation velocity in rubberized concrete are lower than those of plain concrete. Ultrasonic analysis reveals large reductions in the ultrasonic modulus and high sound absorption for tire-rubber concrete.

  8. Normal Anal Examination After Penetration: A Case Report.

    PubMed

    Slingsby, Brett; Goldberg, Amy

    2018-03-01

    Physical findings are rare after anal penetration. Furthermore, children delay in disclosing or are reticent to discuss penetration. A 12-year-old boy presented to medical care multiple times over a several-week period complaining of abdominal pain, bloody diarrhea, and poor appetite. On colonoscopy, he was found to have a cylindrical foreign body (measuring 7 cm tall and 7 cm in diameter) in his rectum, which had been present for at least 2 weeks. He initially denied knowing how the object got into his rectum and later stated that he inserted it himself out of curiosity. One week after the object was removed, follow-up examination using video colposcopy revealed a completely normal anal examination; the patient had a normal anal examination despite known anal penetration and removal of the object. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Children can have a normal anal examination despite anal penetration, and do not always disclose anal penetration. The aforementioned concepts can be applied to situations related to child sexual abuse in the emergency department, where physical examinations are frequently normal and children delay in disclosing the abuse. When there is concern for sexual abuse, even in the absence of a disclosure or examination findings, patients should be referred for a child abuse pediatrics evaluation if available. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Coherent perfect absorption and laser modes in a cylindrical structure of conjugate metamaterials

    NASA Astrophysics Data System (ADS)

    Fu, Yangyang; Xu, Yadong; Chen, Huanyang; Cummer, Steven A.

    2018-01-01

    In this work, we theoretically find that coherent perfect absorption (CPA) and laser modes can be realized in a two-dimensional cylindrical structure composed of conjugate metamaterials (CMs). The required phase factors of CMs for achieving CPA and laser modes are determined by the geometric size of the CM cylinder, which is a unique feature compared with other non-Hermitian optical systems. Based on this property, we also demonstrate that CPA and laser modes can exist simultaneously in a CM cylinder with an extremely large size, where the excitations of CPA and laser modes depend on the angular momentum of coherent incident light. Therefore, compared with the well known parity time symmetry, our work opens up a brand-new path to obtaining CPA and laser modes, and is a significant advance in non-Hermitian optical systems.

  10. A 6-GW NEODYMIUM GLASS LASER,

    DTIC Science & Technology

    A 6-GW neodymium glass laser with a simple phototropic Q-switch is described. The laser consists of three cylindrical rods in series, each 250 mm...operation (50-80 microsec. repetition frequency), the total output was 200 j. The use of a phototropic liquid switch and large-diameter neodymium glass

  11. Analytical model for vibration prediction of two parallel tunnels in a full-space

    NASA Astrophysics Data System (ADS)

    He, Chao; Zhou, Shunhua; Guo, Peijun; Di, Honggui; Zhang, Xiaohui

    2018-06-01

    This paper presents a three-dimensional analytical model for the prediction of ground vibrations from two parallel tunnels embedded in a full-space. The two tunnels are modelled as cylindrical shells of infinite length, and the surrounding soil is modelled as a full-space with two cylindrical cavities. A virtual interface is introduced to divide the soil into the right layer and the left layer. By transforming the cylindrical waves into the plane waves, the solution of wave propagation in the full-space with two cylindrical cavities is obtained. The transformations from the plane waves to cylindrical waves are then used to satisfy the boundary conditions on the tunnel-soil interfaces. The proposed model provides a highly efficient tool to predict the ground vibration induced by the underground railway, which accounts for the dynamic interaction between neighbouring tunnels. Analysis of the vibration fields produced over a range of frequencies and soil properties is conducted. When the distance between the two tunnels is smaller than three times the tunnel diameter, the interaction between neighbouring tunnels is highly significant, at times in the order of 20 dB. It is necessary to consider the interaction between neighbouring tunnels for the prediction of ground vibrations induced underground railways.

  12. Formation of hexagonal boron nitride nanoscrolls induced by inclusion and exclusion of self-assembling molecules in solution process.

    PubMed

    Hwang, Da Young; Suh, Dong Hack

    2014-06-07

    Unlike nanoscrolls of 2D graphene, those of 2D h-BN have not been demonstrated, except for only a few experimental reports. Nanoscrolls of h-BN with high yields and reproducibility are first synthesized by a simple solution process. Inner-tube diameters of BNSs including LCAs, N-(2-aminoethyl)-3α-hydroxy-5β-cholan-24-amide, a bile acid derivative and self-assembling material, can be controlled by adjusting the diameter of the LCA fiber which is grown by self-assembly. TEM and SEM images show that BNSs have a tube-like morphology and the inner-tube diameter of BNSs can be controlled in the range from 20 to 60 nm for a smaller diameter, up to 300 nm for a larger diameter by LCA fiber growth inside the BNSs. Finally, open cylindrical BNSs with hollow cores were obtained by dissolving LCAs inside BNSs.

  13. Review of Kaufman thruster development at the Lewis Research Center - 1973

    NASA Technical Reports Server (NTRS)

    Kerslake, W. R.

    1973-01-01

    Work on Kaufman thruster development completed during the years 1971 and 1972 is reviewed. Thrusters tested have ranged in size from 2.5-cm to 150-cm diameters, in thrust from 0.4 to 4300 mN, and in power from 0.03 to 203 kW. A 2.5-cm thruster was briefly tested and found to have surprisingly high thruster efficiency. Emphasis is placed on thruster system reliability and lifetime as previous work has increased thruster efficiency to a high level. Work also proceeds on definition of thruster-spacecraft interactions. Major R&D efforts are directed at present into two areas of thruster size: a 5-cm to 8-cm diameter thruster to be used for station keeping and attitude control of geosynchronous spacecraft; and a 30-cm diameter thruster to be used for primary propulsion in a 3- to 7-thruster array for solar electric propulsion of interplanetary spacecraft.

  14. Elasto-plastic impact of hemispherical shell impacting on hard rigid sphere

    NASA Technical Reports Server (NTRS)

    Raftopoulos, D. D.; Spicer, A. L.

    1976-01-01

    An analysis of plastic stress waves for cylindrical metallic projectile in impact is extended to an analysis of a hemispherical shell suffereing plastic deformation during the process of impact. It is assumed that the hemispherical shell with a prescribed launch velocity impinges a fixed rigid sphere of diameter equal to the internal diameter of the shell. The dynamic biaxial state of stress present in the shell during deformation is investigated. The analysis is valuable for studying the state of stress during large plastic deformation of a hemispherical shell.

  15. JACKETED FISSIONABLE MEMBER

    DOEpatents

    Boller, E.R.; Robinson, J.W.

    1960-09-13

    A fuel element design for a nuclear reactor is presented. The fuel element comprises a cylindrical fuel body having a portion of smaller diameter at each end thereof with an annular flange at the extreme ends of these portions of smaller diameter. An end cap fits over the ends of the fuel body and has an internal annular groove adapted to receive the flange. The fuel body and end caps are disposed in a cup-shaped jacket, a closure disc completing the enclosure of the fuel body, and tht caps are bonded over their entire periphery to the jacket.

  16. Dismantling of Radium-226 Coal Level Gauges: Encountered Problems and How to Solve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Punnachaiya, M.; Nuanjan, P.; Moombansao, K.

    2006-07-01

    This paper describes the techniques for dismantling of disused-sealed Radium-226 (Ra-226) coal level gauges which the source specifications and documents were not available, including problems occurred during dismantling stage and the decision making in solving all those obstacles. The 2 mCi (20 pieces), 6 mCi (20 pieces) and 6.6 mCi (30 pieces) of Ra-226 hemi-spherically-shaped with lead-filled coal level gauges were used in industrial applications for electric power generation. All sources needed to be dismantled for further conditioning as requested by the International Atomic Energy Agency (IAEA). One of the 2 mCi Ra-226 source was dismantled under the supervision ofmore » IAEA expert. Before conditioning period, each of the 6 mCi and 6.6 mCi sources were dismantled and inspected. It was found that coal level gauges had two different source types: the sealed cylindrical source (diameter 2 cm x 2 cm length) locked with spring in lead housing for 2 mCi and 6.6 mCi; while the 6 mCi was an embedded capsule inside source holder stud assembly in lead-filled housing. Dismantling Ra-226 coal level gauges comprised of 6 operational steps: confirmation of the surface dose rate on each source activity, calculation of working time within the effective occupational dose limit, cutting the weld of lead container by electrical blade, confirmation of the Ra-226 embedded capsule size using radiation scanning technique and gamma radiography, automatic sawing of the source holder stud assembly, and transferring the source to store in lead safe box. The embedded length of 6 mCi Ra-226 capsule in its diameter 2 cm x 14.7 cm length stud assembly was identified, the results from scanning technique and radiographic film revealed the embedded source length of about 2 cm, therefore all the 6 mCi sources were safely cut at 3 cm using the automatic saw. Another occurring problem was one of the 6.6 mCi spring type source stuck inside its housing because the spring was deformed and there was previously a leakage on inner source housing. Thus, during manufacturing the filled-lead for shielding passed through this small hole and fixed the deformed spring together with the source. The circular surface of inner hole was measured and slowly drilled at a diameter 2.2 cm behind shielding, till the spring and the fixed lead sheet were cut, therefore the source could be finally hammered out. The surface dose rate of coal level gauges before weld cutting was 10-15 mR/hr and the highest dose rate at the position of the weld cutter was 2.5 mR/hr. The total time for each weld cutting and automatic sawing was 2-3 minutes and 1 minute, respectively. The source was individually and safely transferred to store in lead safe box using a 1-meter length tong and a light container with 1 meter length handle. The total time for Ra-226 (70 pieces) dismantling, including the encountered problems and their troubles shooting took 4 days operation in which the total dose obtained by 18 operators were ranged from 1-38 {mu}Sv. The dismantling team safely completed the activities within the effective dose limit for occupational exposure of 20 mSv/year (80 {mu}Sv/day). (authors)« less

  17. SU-F-P-47: Estimation of Skin Dose by Performing the Measurements On Cylindrical Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosma, S; Sanders, M; Aryal, P

    Purpose: To evaluate the skin dose by performing the measurements on cylindrical phantom with 6X beam. Methods: A cylindrical phantom was used to best model a patient surface. The source to surface distance (SSD) was 100 cm at phantom surface along central axis (CAX). The EBT2 films were cut into 2×2 cm2 pieces. Each piece of film was placed at CAX on phantom surface for each measurement at 0°, 15°, 30°, 45°, 60°, 75°, and 90° gantry angles for field sizes of 5×5, 10×10, 15×15, and 20×20 cm{sup 2} respectively. One hundred monitor units (MU) with 6X beam were deliveredmore » for each set up. Similarly, the measurements were repeated using lithium fluoride (LiF) thermoluminescent dosimeter (TLD) chips (1X1X1 mm{sup 3}). Two TLD chips were placed for each gantry angle and field size. The calibration curves were produced for both film and TLD. The computed tomography (CT) was also performed on the same cylindrical phantom and dose was evaluated at the phantom surface using Eclipse treatment planning system ( AAA algorithm) for skin dose comparison. Results: Data showed small differences at smaller angles among EBT2, TLD and Eclipse treatment planning system. But Eclipse treatment planning system under estimated the skin dose between 20% and 50% at larger gantry angles (between 40° and 80°) at all field sizes before dose differences began to converge. Conclusion: Given this data, we can conclude that Eclipse treatment planning system under estimated the dose especially between 40 and 80 degrees of obliquity compared to the measurements results. Ideally, this study can be applied largely to head and neck patients where contours differ drastically and where skin dose is paramount.« less

  18. Photosynthetic performance of a helical tubular photobioreactor incorporating the cyanobacterium Spirulina platensis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watanabe, Yoshitomo; Hall, D.O.; Nouee, J. De La

    1995-07-20

    The photosynthetic performance of a helical tubular photobioreactor (``Biocoil``), incorporating the filamentous cyanobacterium Spirulina platensis, was investigated. The photobioreactor was constructed in a cylindrical shape with a 0.25-m{sup 2} basal area and a photostage comprising 60 m of transparent PVC tubing of 1.6-cm inner diameter. The inner surface of the cylinder was illuminated with cool white fluorescent lamps; the energy input of photosynthetically active radiation into the photobioreactor was 2,920 kJ per day. An air-lift system incorporating 4% CO{sub 2} was used to circulate the growth medium in the tubing. The maximum productivity achieved in batch culture was 7.18 gmore » dry biomass per day which corresponded to a photosynthetic (PAR) efficiency of 5.45%. The CO{sub 2} was efficiently removed from the gaseous stream; monitoring the CO{sub 2} in the outlet and inlet gas streams showed a 70% removal of CO{sub 2} from the inlet gas over an 8-h period with almost maximum growth rate.« less

  19. [Infinite optical thickness of dentine porcelain of IPS E.max A color series].

    PubMed

    Sun, Ting; Shao, Long-quan; Yi, Yuan-fu; Deng, Bin; Wen, Ning; Zhang, Wei-wei

    2011-02-01

    To determine the infinite optical thickness of dentine porcelain of IPS E.max A color series. Cylindrical dentine porcelain specimens of the IPS E.max A color series were prepared with a diameter of 13 mm and thickness of 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, and 5.0 mm. The chromatic value of all the specimens was determined with CM-5 spectrometer against standard black and white background. The chromatic aberration (deltaE) was calculated by regression equation. The infinite optical thickness of dentine porcelain of the IPS E.max A color series ranged from 2.341 to 3.333 mm for a deltaE of 1.0, and from 2.064 to 2.904 mm for a deltaE of 1.5. As the chromaticity or thickness increased, the influence by the background color decreased, and the color of specimens became gradually close to the intrinsic color. The thickness of the background dentine porcelain specimens must exceed its infinite optical thickness to represent the intrinsic color and avoid the influence by the extrinsic color.

  20. Dioctophyma renale (Goeze, 1782) in the abdominal cavity of a capuchin monkey (Cebus apella), Brazil.

    PubMed

    Ishizaki, Mirian Naomi; Imbeloni, Aline Amaral; Muniz, José Augusto Pereira Carneiro; Scalercio, Sarah Raphaella Rocha de Azevedo; Benigno, Raimundo Nonato Moraes; Pereira, Washington Luiz Assunção; Cunha Lacreta Junior, Antonio Carlos

    2010-10-29

    This study reports a case of parasitism by Dioctophyma renale (Goeze, 1762) encysted in the abdominal cavity of a capuchin monkey (Cebus apella) coming from the Centro Nacional de Primatas, Brazil. The animal was sent to the Veterinary Clinic sector with an increase in abdominal volume and no occurrence of any other clinical signs. Upon palpation, a movable circular mass with a diameter of approximately 10 cm was found. Urinalysis, complete blood count and serum biochemistry were performed without revealing any alterations. The animal was then submitted to an abdominal ultrasound exam. The cyst was punctured and a surgical removal procedure was performed, revealing a brownish-colored cylindrical structure that was already deteriorated, making it impossible to perform morphological analysis and classification. In the sediment of the liquid found, eggs were encountered that had morphological characteristics compatible with D. renale. The objective of this paper is to report the first case of parasitism by D. renale in C. apella (Linnaeus, 1758). Copyright © 2010 Elsevier B.V. All rights reserved.

  1. EPICS Controlled Collimator for Controlling Beam Sizes in HIPPO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Napolitano, Arthur Soriano; Vogel, Sven C.

    2017-08-03

    Controlling the beam spot size and shape in a diffraction experiment determines the probed sample volume. The HIPPO - High-Pressure-Preferred Orientation– neutron time-offlight diffractometer is located at the Lujan Neutron Scattering Center in Los Alamos National Laboratories. HIPPO characterizes microstructural parameters, such as phase composition, strains, grain size, or texture, of bulk (cm-sized) samples. In the current setup, the beam spot has a 10 mm diameter. Using a collimator, consisting of two pairs of neutron absorbing boron-nitride slabs, horizontal and vertical dimensions of a rectangular beam spot can be defined. Using the HIPPO robotic sample changer for sample motion, themore » collimator would enable scanning of e.g. cylindrical samples along the cylinder axis by probing slices of such samples. The project presented here describes implementation of such a collimator, in particular the motion control software. We utilized the EPICS (Experimental Physics Interface and Control System) software interface to integrate the collimator control into the HIPPO instrument control system. Using EPICS, commands are sent to commercial stepper motors that move the beam windows.« less

  2. Secondary aspiration of aerosol particles into thin-walled nozzles facing the wind

    NASA Astrophysics Data System (ADS)

    Lipatov, G. N.; Grinshpun, S. A.; Semenyuk, T. I.; Sutugin, A. G.

    Problems of sampling aerosols from the turbulent atmosphere have been studied experimentally. The research was carried out with such particle sizes, type of samplers and sampling conditions that relate to those encountered in practical occupational hygiene and environmental monitoring. Distortion of the aerosol initial concentration was measured in a wind tunnel by a comparison method. Such distortions were caused by the external aspiration from a turbulent down flow using a vertical thin-walled cylindrical sampler. In addition, inertial errors themselves were determined by the limiting trajectory method. The difference between the results obtained with the help of the above methods showed the presence of secondary aspiration after the particles rebound from the outer nozzle surface for anisokinetical sampling. This fact was established by means of a set of special experiments with nozzles of various properties of the outer surface. Values of the rebound coefficient for Lycopodium particles aspirated into copper samplers over a range of diameters of 0.5-1 cm and anisokinetical coefficients (velocity ratio) of 1-40 were obtained. The conditions under which the efficiency of secondary aspiration is small were also defined.

  3. Numerical Study On Propulsion Performance Of The Parabolic Laser Thruster With Elongate Cylinder Nozzle

    NASA Astrophysics Data System (ADS)

    Cheng, Fuqiang; Hong, Yanji; Li, Qian; Wen, Ming

    2011-11-01

    Laser thrusters with a single nozzle, e.g. parabolic or conical, failed to constrict the flow field of high pressure effectively, resulting in poor propulsive performance. Under the condition of air-breathing mode, parabolic thruster models with an elongate cylinder nozzle were studied numerically by building a physical computation model. Initially, to verify the computation model, the influence of cylinder length on the momentum coupling coefficient was computed and compared with the experiments, which shows a good congruence. A model of diameter 20 mm and cylindrical length 80 mm obtains about 627.7 N/MW at single pulse energy density 1.5 J/cm2. Then, the influence of expanding angle of the parabolic nozzle on propulsion performance was gained for different laser pulse energies, and the evolution process of the flow field was analyzed. The results show: as the expanding angel increases, the momentum coupling coefficient increases remarkably at first and descends relative slowly after reaching a peak value; moreover, the peak positions stay constant around 33° with little variation when laser energy differs.

  4. Charging and discharging Teflon

    NASA Technical Reports Server (NTRS)

    Passenheim, B. C.; Vanlint, V. A. J.

    1981-01-01

    The charging and discharging characteristics of several common satellite materials exposed to 0-30KV electrons are measured. Teflon is discussed because the charging characteristics are radically altered immediately after a spontaneous discharge. The exterior geometry of the test structure is shown. In all cases dielectric samples were 82 cm in diameter mounted on the front of a 120 cm diameter cylinder supported on an 85 cm, 0.95 cm thick plexiglass disc. Dielectric materials investigated were: back surface aluminized Kapton, back surface silvered Teflon, silicon alkyd white thermal control paint, and 50 cm by 50 cm array of 0.030 cm thick MgF2 coated fused silica solar cell cover slips.

  5. Theoretical Modeling of the Interior Ballistics of the Electrothermal Gun

    DTIC Science & Technology

    1993-07-01

    latter one 19 Table 2.1 Parameters Used for Nominal Data Base (after Oberle [2]). Chamber Volume 97.108 cm 3 Projectile Travel 145 cm Bore Diameter 14...at the time when the plasma supply is completed. When this occurs in the case of instantaneous mixing one has the projectile travel reduced by... Travel 400.0 cm Bore Diameter 4.0 cm Projectile Hass 160 g Plasma Energy 2000000 J Plasma Mass 0.0 g Working Fluid 420 g of H20 Density I g/cm. Bulk

  6. Grid-translation beam deflection systems for 5-cm and 30-cm diameter Kaufman thrusters.

    NASA Technical Reports Server (NTRS)

    Lathem, W. C.

    1972-01-01

    A 5-cm grid translation mechanism has been developed capable of 10-deg beam deflection. A 2026-hour endurance test was run at a preset 10-deg deflection angle, and an extrapolated lifetime of better than 10,000 hours was obtained. Response time data for grid translation are presented. Preliminary results for a 30-cm diameter system are given, and results of a theoretical analysis of a dished grid system are discussed.

  7. Grid-translation beam deflection systems for 5-cm and 30-cm diameter Kaufman thrusters

    NASA Technical Reports Server (NTRS)

    Lathem, W. C.

    1972-01-01

    A 5-cm grid translation mechanism has been developed capable of 10 deg beam deflection. A 2026-hour endurance test was run at a preset 10 deg deflection angle and an extrapolated lifetime of better than 10,000 hours obtained. Response time data for grid translation are presented. Preliminary results for a 30-cm diameter system are given and results of a theoretical analysis of a dished grid system are discussed.

  8. Simulation and Testing of a Linear Array of Modified Four-Square Feed Antennas for the Tianlai Cylindrical Radio Telescope

    NASA Astrophysics Data System (ADS)

    Cianciara, Aleksander J.; Anderson, Christopher J.; Chen, Xuelei; Chen, Zhiping; Geng, Jingchao; Li, Jixia; Liu, Chao; Liu, Tao; Lu, Wing; Peterson, Jeffrey B.; Shi, Huli; Steffel, Catherine N.; Stebbins, Albert; Stucky, Thomas; Sun, Shijie; Timbie, Peter T.; Wang, Yougang; Wu, Fengquan; Zhang, Juyong

    A wide bandwidth, dual polarized, modified four-square antenna is presented as a feed antenna for radio astronomical measurements. A linear array of these antennas is used as a line-feed for cylindrical reflectors for Tianlai, a radio interferometer designed for 21cm intensity mapping. Simulations of the feed antenna beam patterns and scattering parameters are compared to experimental results at multiple frequencies across the 650-1420MHz range. Simulations of the beam patterns of the combined feed array/reflector are presented as well.

  9. Brown rot in inner heartwood: why large logs support characteristics saproxylic beetle assemblages of conservation concern

    Treesearch

    Marie Yee; Simon J. Grove; Alastair M.M. Richardson; Caroline L. Mohammed

    2006-01-01

    It is not clear why large diameter logs generally host saproxylic beetle assemblages that are different from those of small diameter logs. In a study in Tasmanian wet eucalypt forest, two size-classes of Eucalyptus obliqua logs (>100cm and 30-60cm diameter) were destructively sampled to assess their beetle fauna and the associations of this fauna...

  10. A comparison of pine height models for the Crossett Experimental Forest

    Treesearch

    D. Bragg

    2008-01-01

    Many models to predict tree height from diameter have been developed, but not all are equally useful. This study compared a set of height diameter models for loblolly (Pinus taeda) and shortleaf (Pinus echinata) pines from Ashley County, Arkansas. Almost 560 trees ranging in diameter at breast height (DBH) from 0.3 cm (both species) to 91.9 cm (for shortleaf) or 108.2...

  11. Experimental investigation of the effect of air cavity size in cylindrical ionization chambers on the measurements in 60Co radiotherapy beams

    NASA Astrophysics Data System (ADS)

    Swanpalmer, John; Johansson, Karl-Axel

    2011-11-01

    In the late 1970s, Johansson et al (1978 Int. Symp. National and International Standardization of Radiation Dosimetry (Atlanta 1977) vol 2 (Vienna: IAEA) pp 243-70) reported experimentally determined displacement correction factors (pdis) for cylindrical ionization chamber dosimetry in 60Co and high-energy photon beams. These pdis factors have been implemented and are currently in use in a number of dosimetry protocols. However, the accuracy of these factors has recently been questioned by Wang and Rogers (2009a Phys. Med. Biol. 54 1609-20), who performed Monte Carlo simulations of the experiments performed by Johansson et al. They reported that the inaccuracy of the pdis factors originated from the normalization procedure used by Johansson et al. In their experiments, Johansson et al normalized the measured depth-ionization curves at the depth of maximum ionization for each of the different ionization chambers. In this study, we experimentally investigated the effect of air cavity size of cylindrical ionization chambers in a PMMA phantom and 60Co γ-beam. Two different pairs of air-filled cylindrical ionization chambers were used. The chambers in each pair had identical construction and materials but different air cavity volume (diameter). A 20 MeV electron beam was utilized to determine the ratio of the mass of air in the cavity of the two chambers in each pair. This ratio of the mass of air in each pair was then used to compare the ratios of the ionizations obtained at different depths in the PMMA phantom and 60Co γ-beam using the two pairs of chambers. The diameter of the air cavity of cylindrical ionization chambers influences both the depth at which the maximum ionization is observed and the ionization per unit mass of air at this depth. The correction determined at depths of 50 mm and 100 mm is smaller than the correction currently used in many dosimetry protocols. The results presented here agree with the findings of Wang and Rogers' Monte Carlo simulations and show that the normalization procedure employed by Johansson et al is not correct.

  12. Rationally designed graphene-nanotube 3D architectures with a seamless nodal junction for efficient energy conversion and storage

    PubMed Central

    Xue, Yuhua; Ding, Yong; Niu, Jianbing; Xia, Zhenhai; Roy, Ajit; Chen, Hao; Qu, Jia; Wang, Zhong Lin; Dai, Liming

    2015-01-01

    One-dimensional (1D) carbon nanotubes (CNTs) and 2D single-atomic layer graphene have superior thermal, electrical, and mechanical properties. However, these nanomaterials exhibit poor out-of-plane properties due to the weak van der Waals interaction in the transverse direction between graphitic layers. Recent theoretical studies indicate that rationally designed 3D architectures could have desirable out-of-plane properties while maintaining in-plane properties by growing CNTs and graphene into 3D architectures with a seamless nodal junction. However, the experimental realization of seamlessly-bonded architectures remains a challenge. We developed a strategy of creating 3D graphene-CNT hollow fibers with radially aligned CNTs (RACNTs) seamlessly sheathed by a cylindrical graphene layer through a one-step chemical vapor deposition using an anodized aluminum wire template. By controlling the aluminum wire diameter and anodization time, the length of the RACNTs and diameter of the graphene hollow fiber can be tuned, enabling efficient energy conversion and storage. These fibers, with a controllable surface area, meso-/micropores, and superior electrical properties, are excellent electrode materials for all-solid-state wire-shaped supercapacitors with poly(vinyl alcohol)/H2SO4 as the electrolyte and binder, exhibiting a surface-specific capacitance of 89.4 mF/cm2 and length-specific capacitance up to 23.9 mF/cm, — one to four times the corresponding record-high capacities reported for other fiber-like supercapacitors. Dye-sensitized solar cells, fabricated using the fiber as a counter electrode, showed a power conversion efficiency of 6.8% and outperformed their counterparts with an expensive Pt wire counter electrode by a factor of 2.5. These novel fiber-shaped graphene-RACNT energy conversion and storage devices are so flexible they can be woven into fabrics as power sources. PMID:26601246

  13. SU-G-206-06: Analytic Dose Function for CT Scans in Infinite Cylinders as a Function of Scan Length and Cylinder Radius

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakalyar, D; Feng, W; McKenney, S

    Purpose: The radiation dose absorbed at a particular radius ρ within the central plane of a long cylinder following a CT scan is a function of the length of the scan L and the cylinder radius R along with kVp and cylinder composition. An analytic function was created that that not only expresses these dependencies but is integrable in closed form over the area of the central plane. This feature facilitates explicit calculation of the planar average dose. The “approach to equilibrium” h(L) discussed in the TG111 report is seamlessly included in this function. Methods: For a cylindrically symmetric radiationmore » field, Monte Carlo calculations were performed to compute the dose distribution to long polyethylene cylinders for scans of varying L for cylinders ranging in radius from 5 to 20 cm. The function was developed from the resultant Monte Carlo data. In addition, the function was successfully fit to data taken from measurements on the 30 cm diameter ICRU/TG200 phantom using a real-time dosimeter. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. There are competing effects as the beam penetrates the cylinder from the outside: attenuation, resulting in a decrease; scatter, abruptly increasing at the circumference. This competition may result in an absolute maximum between the center and outer edge leading to a “gull wing” shape for the radial dependence. For the smallest cylinders, scatter may dominate to the extent that there is an absolute maximum at the center. Conclusion: An integrable, analytic function has been developed that provides the radial dependency of dose for the central plane of a scan of length L for cylinders of varying diameter. Equivalently, we have developed h(L,R,ρ).« less

  14. Rationally designed graphene-nanotube 3D architectures with a seamless nodal junction for efficient energy conversion and storage.

    PubMed

    Xue, Yuhua; Ding, Yong; Niu, Jianbing; Xia, Zhenhai; Roy, Ajit; Chen, Hao; Qu, Jia; Wang, Zhong Lin; Dai, Liming

    2015-09-01

    One-dimensional (1D) carbon nanotubes (CNTs) and 2D single-atomic layer graphene have superior thermal, electrical, and mechanical properties. However, these nanomaterials exhibit poor out-of-plane properties due to the weak van der Waals interaction in the transverse direction between graphitic layers. Recent theoretical studies indicate that rationally designed 3D architectures could have desirable out-of-plane properties while maintaining in-plane properties by growing CNTs and graphene into 3D architectures with a seamless nodal junction. However, the experimental realization of seamlessly-bonded architectures remains a challenge. We developed a strategy of creating 3D graphene-CNT hollow fibers with radially aligned CNTs (RACNTs) seamlessly sheathed by a cylindrical graphene layer through a one-step chemical vapor deposition using an anodized aluminum wire template. By controlling the aluminum wire diameter and anodization time, the length of the RACNTs and diameter of the graphene hollow fiber can be tuned, enabling efficient energy conversion and storage. These fibers, with a controllable surface area, meso-/micropores, and superior electrical properties, are excellent electrode materials for all-solid-state wire-shaped supercapacitors with poly(vinyl alcohol)/H2SO4 as the electrolyte and binder, exhibiting a surface-specific capacitance of 89.4 mF/cm(2) and length-specific capacitance up to 23.9 mF/cm, - one to four times the corresponding record-high capacities reported for other fiber-like supercapacitors. Dye-sensitized solar cells, fabricated using the fiber as a counter electrode, showed a power conversion efficiency of 6.8% and outperformed their counterparts with an expensive Pt wire counter electrode by a factor of 2.5. These novel fiber-shaped graphene-RACNT energy conversion and storage devices are so flexible they can be woven into fabrics as power sources.

  15. SU-F-207-05: Excess Heat Corrections in a Prototype Calorimeter for Direct Realization of CT Absorbed Dose to Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen-Mayer, H; Tosh, R

    2015-06-15

    Purpose: To reconcile air kerma and calorimetry measurements in a prototype calorimeter for obtaining absorbed dose in diagnostic CT beams. While corrections for thermal artifacts are routine and generally small in calorimetry of radiotherapy beams, large differences in relative stopping powers of calorimeter materials at the lower energies typical of CT beams greatly magnify their effects. Work-to-date on the problem attempts to reconcile laboratory measurements with modeling output from Monte Carlo and finite-element analysis of heat transfer. Methods: Small thermistor beads were embedded in a polystyrene (PS) core element of 1 cm diameter, which was inserted into a cylindrical HDPEmore » phantom of 30 cm diameter and subjected to radiation in a diagnostic CT x-ray imaging system. Resistance changes in the thermistors due to radiation heating were monitored via lock-in amplifier. Multiple 3-second exposures were recorded at 8 different dose-rates from the CT system, and least-squares fits to experimental data were compared to an expected thermal response obtained by finite-element analysis incorporating source terms based on semi-empirical modeling and Monte Carlo simulation. Results: Experimental waveforms exhibited large thermal artifacts with fast time constants, associated with excess heat in wires and glass, and smaller steps attributable to radiation heating of the core material. Preliminary finite-element analysis follows the transient component of the signal qualitatively, but predicts a slower decay of temperature spikes. This was supplemented by non-linear least-squares fits incorporating semi-empirical formulae for heat transfer, which were used to obtain dose-to-PS in reasonable agreement with the output of Monte Carlo calculations that converts air kerma to absorbed dose. Conclusion: Discrepancies between the finite-element analysis and our experimental data testify to the very significant heat transfer correction required for absorbed dose calorimetry of diagnostic CT beams. The results obtained here are being used to refine both simulations and design of calorimeter core components.« less

  16. A novel optical detector concept for dedicated and multi-modality in vivo small animal imaging

    NASA Astrophysics Data System (ADS)

    Peter, Jörg; Schulz, Ralf B.; Unholtz, Daniel; Semmler, Wolfhard

    2007-07-01

    An optical detector suitable for inclusion in tomographic arrangements for non-contact in vivo bioluminescence and fluorescence imaging applications is proposed. It consists of a microlens array (MLA) intended for field-of-view definition, a large-field complementary metal-oxide-semiconductor (CMOS) chip for light detection, a septum mask for cross-talk suppression, and an exchangeable filter to block excitation light. Prototype detector units with sensitive areas of 2.5 cm x 5 cm each were assembled. The CMOS sensor constitutes a 512 x 1024 photodiode matrix at 48 μm pixel pitch. Refractive MLAs with plano-convex lenses of 480 μm in diameter and pitch were selected resulting in a 55 x 105 lens matrix. The CMOS sensor is aligned on the focal plane of the MLA at 2.15mm distance. To separate individual microlens images an opaque multi-bore septum mask of 2.1mm in thickness and bore diameters of 400 μm at 480 μm pitch, aligned with the lens pattern, is placed between MLA and CMOS. Intrinsic spatial detector resolution and sensitivity was evaluated experimentally as a function of detector-object distance. Due to its small overall dimensions such detectors can be favorably packed for tomographic imaging (optical diffusion tomography, ODT) yielding complete 2 π field-of-view coverage. We also present a design study of a device intended to simultaneously image positron labeled substrates (positron emission tomography, PET) and optical molecular probes in small animals such as mice and rats. It consists of a cylindrical allocation of optical detector units which form an inner detector ring while PET detector blocks are mounted in radial extension, those gaining complementary information in a single, intrinsically coregistered experimental data acquisition study. Finally, in a second design study we propose a method for integrated optical and magnetic resonance imaging (MRI) which yields in vivo functional/molecular information that is intrinsically registered with the anatomy of the image object.

  17. Selectable-Tip Corrosion-Testing Electrochemical Cell

    NASA Technical Reports Server (NTRS)

    Lomness, Janice; Hintze, Paul

    2008-01-01

    The figure depicts aspects of an electrochemical cell for pitting- corrosion tests of material specimens. The cell is designed to generate a region of corrosion having a pit diameter determined by the diameter of a selectable tip. The average depth of corrosion is controlled by controlling the total electric charge passing through the cell in a test. The cell is also designed to produce minimal artifacts associated with crevice corrosion. There are three selectable tips, having diameters of 0.1 in. (0.254 cm), 0.3 in. (0.762 cm), and 0.6 in. (1.524 cm), respectively.

  18. Microcrystalline diamond cylindrical resonators with quality-factor up to 0.5 million

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saito, Daisuke; Yang, Chen; Lin, Liwei

    2016-02-01

    We demonstrate high quality-factor 1.5 mm diameter batch-fabricated microcrystalline diamond cylindrical resonators (CR) with quality-factors limited by thermoelastic damping (TED) and surface loss. Resonators were fabricated 2.6 and 5.3 μm thick in-situ boron-doped microcrystalline diamond films deposited using hot filament chemical vapor deposition. The quality-factor (Q) of as-fabricated CR's was found to increase with the resonator diameter and diamond thickness. Annealing the CRs at 700 °C in a nitrogen atmosphere led to a three-fold increase in Q, a result we attribute to thinning of the diamond layer via reaction with residual O{sub 2} in the annealing furnace. Post-anneal Q exceeding 0.5 million (528 000)more » was measured at the 19 kHz elliptical wineglass modes, producing a ring-down time of 8.9 s. A model for Q versus diamond thickness and resonance frequency is developed including the effects of TED and surface loss. Measured quality factors are shown to agree with the predictions of this model.« less

  19. Novel cylindrical illuminator tip for ultraviolet light delivery

    NASA Astrophysics Data System (ADS)

    Shangguan, HanQun; Haw, Thomas E.; Gregory, Kenton W.; Casperson, Lee W.

    1993-06-01

    The design, processing, and sequential testing of a novel cylindrical diffusing optical fiber tip for ultraviolet light delivery is described. This device has been shown to uniformly (+/- 15%) illuminate angioplasty balloons, 20 mm in length, that are used in an experimental photochemotherapeutic treatment of swine intimal hyperplasia. Our experiments show that uniform diffusing tips of < 400 micron diameter can be reliably constructed for this and other interstitial applications. Modeling results indicate that this design is scalable to smaller diameters. The diffusing tips are made by stripping the protective buffer and etching away the cladding over a length of 20 mm from the fiber tip and replacing it with a thin layer of optical epoxy mixed with Al2O3 powder. To improve the uniformity and ease of fabrication, we have evaluated a new device configuration where the tip is etched into a modified conical shape, and the distal end face is polished and then coated with an optically opaque epoxy. This is shown to uniformly scatter approximately 70% of the light launched into the fiber without forward transmission.

  20. Real-time continuous-wave terahertz line scanner based on a compact 1 × 240 InGaAs Schottky barrier diode array detector.

    PubMed

    Han, Sang-Pil; Ko, Hyunsung; Kim, Namje; Lee, Won-Hui; Moon, Kiwon; Lee, Il-Min; Lee, Eui Su; Lee, Dong Hun; Lee, Wangjoo; Han, Seong-Tae; Choi, Sung-Wook; Park, Kyung Hyun

    2014-11-17

    We demonstrate real-time continuous-wave terahertz (THz) line-scanned imaging based on a 1 × 240 InGaAs Schottky barrier diode (SBD) array detector with a scan velocity of 25 cm/s, a scan line length of 12 cm, and a pixel size of 0.5 × 0.5 mm². Foreign substances, such as a paper clip with a spatial resolution of approximately 1 mm that is hidden under a cracker, are clearly detected by this THz line-scanning system. The system consists of the SBD array detector, a 200-GHz gyrotron source, a conveyor system, and several optical components such as a high-density polyethylene cylindrical lens, metal cylindrical mirror, and THz wire-grid polarizer. Using the THz polarizer, the signal-to-noise ratio of the SBD array detector improves because the quality of the source beam is enhanced.

  1. Correlation between mass transfer coefficient kLa and relevant operating parameters in cylindrical disposable shaken bioreactors on a bench-to-pilot scale

    PubMed Central

    2013-01-01

    Background Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation. Results A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham’s π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures. Conclusion The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/− 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale. PMID:24289110

  2. Modelling of heat transfer during torrefaction of large lignocellulosic biomass

    NASA Astrophysics Data System (ADS)

    Regmi, Bharat; Arku, Precious; Tasnim, Syeda Humaira; Mahmud, Shohel; Dutta, Animesh

    2018-02-01

    Preparation of feedstock is a major energy intensive process for the thermochemical conversion of biomass into fuel. By eliminating the need to grind biomass prior to the torrefaction process, there would be a potential gain in the energy requirements as the entire step would be eliminated. In regards to a commercialization of torrefaction technology, this study has examined heat transfer inside large cylindrical biomass both numerically and experimentally during torrefaction. A numerical axis-symmetrical 2-D model for heat transfer during torrefaction at 270°C for 1 h was created in COMSOL Multiphysics 5.1 considering heat generation evaluated from the experiment. The model analyzed the temperature distribution within the core and on the surface of biomass during torrefaction for various sizes. The model results showed similarities with experimental results. The effect of L/D ratio on temperature distribution within biomass was observed by varying length and diameter and compared with experiments in literature to find out an optimal range of cylindrical biomass size suitable for torrefaction. The research demonstrated that a cylindrical biomass sample of 50 mm length with L/D ratio of 2 can be torrefied with a core-surface temperature difference of less than 30 °C. The research also demonstrated that sample length has a negligible effect on core-surface temperature difference during torrefaction when the diameter is fixed at 25 mm. This information will help to design a torrefaction processing system and develop a value chain for biomass supply without using an energy-intensive grinding process.

  3. Modelling of heat transfer during torrefaction of large lignocellulosic biomass

    NASA Astrophysics Data System (ADS)

    Regmi, Bharat; Arku, Precious; Tasnim, Syeda Humaira; Mahmud, Shohel; Dutta, Animesh

    2018-07-01

    Preparation of feedstock is a major energy intensive process for the thermochemical conversion of biomass into fuel. By eliminating the need to grind biomass prior to the torrefaction process, there would be a potential gain in the energy requirements as the entire step would be eliminated. In regards to a commercialization of torrefaction technology, this study has examined heat transfer inside large cylindrical biomass both numerically and experimentally during torrefaction. A numerical axis-symmetrical 2-D model for heat transfer during torrefaction at 270°C for 1 h was created in COMSOL Multiphysics 5.1 considering heat generation evaluated from the experiment. The model analyzed the temperature distribution within the core and on the surface of biomass during torrefaction for various sizes. The model results showed similarities with experimental results. The effect of L/D ratio on temperature distribution within biomass was observed by varying length and diameter and compared with experiments in literature to find out an optimal range of cylindrical biomass size suitable for torrefaction. The research demonstrated that a cylindrical biomass sample of 50 mm length with L/D ratio of 2 can be torrefied with a core-surface temperature difference of less than 30 °C. The research also demonstrated that sample length has a negligible effect on core-surface temperature difference during torrefaction when the diameter is fixed at 25 mm. This information will help to design a torrefaction processing system and develop a value chain for biomass supply without using an energy-intensive grinding process.

  4. Correlation between mass transfer coefficient kLa and relevant operating parameters in cylindrical disposable shaken bioreactors on a bench-to-pilot scale.

    PubMed

    Klöckner, Wolf; Gacem, Riad; Anderlei, Tibor; Raven, Nicole; Schillberg, Stefan; Lattermann, Clemens; Büchs, Jochen

    2013-12-02

    Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation. A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham's π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures. The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/- 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale.

  5. Experimental Results for an Acoustic Driver for MTF

    NASA Astrophysics Data System (ADS)

    Laberge, Michel

    2009-06-01

    General Fusion is planning to form an FRC or spheromak of 1017 cm-3, 100 eV, 40 cm diameter by merging two spheromaks with reverse or co-helicity. This target will be further compressed in a 3 m diameter tank filled with liquid PbLi with the plasma in the center. The tank is surrounded with pneumatically powered impact pistons that will send a convergent shock wave in the liquid to compress the plasma to 1020 cm-3, 10 keV, 4 cm diameter for 7 μs. General Fusion has built a 500 kJ, 80 μs, 6 GW pneumatic impact piston capable of developing 2 GPa (300 kpsi). In this paper we will present the performances achieved to date.

  6. Automated estimation of abdominal effective diameter for body size normalization of CT dose.

    PubMed

    Cheng, Phillip M

    2013-06-01

    Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.

  7. Paramagnetic Liquid Bridge in a Gravity-Compensating Magnetic Field

    NASA Technical Reports Server (NTRS)

    Mahajan, Milind P.; Tsige, Mesfin; Taylor, P. L.; Rosenblatt, Charles

    1999-01-01

    Magnetic levitation was used to stabilize cylindrical columns of a paramagnetic liquid in air between two solid supports. The maximum achievable length to diameter ratio R(sub max) was approx. (3.10 +/- 0.07), very close to the Rayleigh-Plateau limit of pi. For smaller R, the stability of the column was measured as a function of the Bond number, which could be continuously varied by adjusting the strength of the magnetic field. Liquid bridges supported by two solid surfaces have been attracting scientific attention since the time of Rayleigh and Plateau. For a cylindrical bridge of length L and diameter d, it was shown theoretically that in zero gravity the maximum slenderness ratio R (identically = L/d) is pi. The stability and ultimate collapse of such bridges is of interest because of their importance in a number of industrial processes and their potential for low gravity applications. In the presence of gravity, however, the cylindrical shape of an axisymmetric bridge tends to deform, limiting its stability and decreasing the maximum achievable value of R. Theoretical studies have discussed the stability and possible shapes of axisymmetric bridges. Experiments typically are performed in either a Plateau tank, in which the bridge is surrounded by a density-matched immiscible fluid, or in a space-borne microgravity environment. It has been shown, for example, that the stability limit R can be pushed beyond pi by using flow stabilization, by acoustic radiation pressure, or by forming columns in the presence of an axial electric field. In this work, magnetic levitation was used to simulate a low gravity environment and create quasi-cylindrical liquid columns in air. Use of a magnetic field permits us to continuously vary the Bond number B identically equal to (g)(rho)d(exp 2)/4(sigma), where g is the gravitational acceleration, rho is the density of the liquid, and sigma is the surface tension of the liquid in air. The dimensionless Bond number represents the relative importance of external forces acting on the liquid column to those due to surface tension. Our central result is that in a large magnetic field gradient we could create and stabilize columns of mixtures of water and paramagnetic manganese chloride tetrahydrate (MnCl2.4H2O), achieving a length to diameter ratio very close to pi.

  8. NMR spectroscopy up to 35.2T using a series-connected hybrid magnet.

    PubMed

    Gan, Zhehong; Hung, Ivan; Wang, Xiaoling; Paulino, Joana; Wu, Gang; Litvak, Ilya M; Gor'kov, Peter L; Brey, William W; Lendi, Pietro; Schiano, Jeffrey L; Bird, Mark D; Dixon, Iain R; Toth, Jack; Boebinger, Gregory S; Cross, Timothy A

    2017-11-01

    The National High Magnetic Field Laboratory has brought to field a Series-Connected Hybrid magnet for NMR spectroscopy. As a DC powered magnet it can be operated at fields up to 36.1T. The series connection between a superconducting outsert and a resistive insert dramatically minimizes the high frequency fluctuations of the magnetic field typically observed in purely resistive magnets. Current-density-grading among various resistive coils was used for improved field homogeneity. The 48mm magnet bore and 42mm outer diameter of the probes leaves limited space for conventional shims and consequently a combination of resistive and ferromagnetic shims are used. Field maps corrected for field instabilities were obtained and shimming achieved better than 1ppm homogeneity over a cylindrical volume of 1cm diameter and height. The magnetic field is regulated within 0.2ppm using an external 7 Li lock sample doped with paramagnetic MnCl 2 . The improved field homogeneity and field regulation using a modified AVANCE NEO console enables NMR spectroscopy at 1 H frequencies of 1.0, 1.2 and 1.5GHz. NMR at 1.5GHz reflects a 50% increase in field strength above the highest superconducting magnets currently available. Three NMR probes have been constructed each equipped with an external lock rf coil for field regulation. Initial NMR results obtained from the SCH magnet using these probes illustrate the very exciting potential of ultra-high magnetic fields. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. NMR spectroscopy up to 35.2 T using a series-connected hybrid magnet

    NASA Astrophysics Data System (ADS)

    Gan, Zhehong; Hung, Ivan; Wang, Xiaoling; Paulino, Joana; Wu, Gang; Litvak, Ilya M.; Gor'kov, Peter L.; Brey, William W.; Lendi, Pietro; Schiano, Jeffrey L.; Bird, Mark D.; Dixon, Iain R.; Toth, Jack; Boebinger, Gregory S.; Cross, Timothy A.

    2017-11-01

    The National High Magnetic Field Laboratory has brought to field a Series-Connected Hybrid magnet for NMR spectroscopy. As a DC powered magnet it can be operated at fields up to 36.1 T. The series connection between a superconducting outsert and a resistive insert dramatically minimizes the high frequency fluctuations of the magnetic field typically observed in purely resistive magnets. Current-density-grading among various resistive coils was used for improved field homogeneity. The 48 mm magnet bore and 42 mm outer diameter of the probes leaves limited space for conventional shims and consequently a combination of resistive and ferromagnetic shims are used. Field maps corrected for field instabilities were obtained and shimming achieved better than 1 ppm homogeneity over a cylindrical volume of 1 cm diameter and height. The magnetic field is regulated within 0.2 ppm using an external 7Li lock sample doped with paramagnetic MnCl2. The improved field homogeneity and field regulation using a modified AVANCE NEO console enables NMR spectroscopy at 1H frequencies of 1.0, 1.2 and 1.5 GHz. NMR at 1.5 GHz reflects a 50% increase in field strength above the highest superconducting magnets currently available. Three NMR probes have been constructed each equipped with an external lock rf coil for field regulation. Initial NMR results obtained from the SCH magnet using these probes illustrate the very exciting potential of ultra-high magnetic fields.

  10. Comparison of epidermal/dermal damage between the long-pulsed 1064 nm Nd:YAG and 755 nm alexandrite lasers under relatively high fluence conditions: quantitative and histological assessments.

    PubMed

    Lee, Ju Hwan; Park, So Ra; Jo, Jeong Ho; Park, Sung Yun; Seo, Young Kwon; Kim, Sung Min

    2014-07-01

    The purpose of this study was to compare degrees of epidermal/dermal tissue damage quantitatively and histologically after laser irradiation, to find ideal treatment conditions with relatively high fluence for skin rejuvenation. A number of recent studies have evaluated the clinical efficacy and safety of therapeutic lasers under relatively low fluence conditions. We transmitted the long-pulsed 1064 nm Nd:YAG and 755 nm Alexandrite lasers into pig skin according to different fluences and spot diameters, and estimated epidermal/dermal temperatures. Pig skin specimens were stained with hematoxylin and eosin for histological assessments. The fluence conditions comprised 26, 30, and 36 J/cm2, and the spot diameter conditions were 5, 8, and 10 mm. Pulse duration was 30 ms for all experiments. Both lasers produced reliable thermal damage on the dermis without any serious epidermal injuries, under relatively high fluence conditions. The 1064 nm laser provided more active fibrous formations than the 755 nm laser, while higher risks for tissue damages simultaneously occurred. The ideal treatment conditions for skin rejuvenation were 8 mm diameter with 30 J/cm2 and 10 mm diameter with 26 J/cm2 for the 1064 nm laser, and 8 mm diameter with 36 J/cm2 and 10 mm diameter with 26 J/cm2 for the 755 nm laser.

  11. Pilot study: safety and effectiveness of simple ultrasound-guided high-intensity focused ultrasound ablating uterine leiomyoma with a diameter greater than 10 cm.

    PubMed

    Hou, Ruijie; Wang, Liwei; Li, Shaoping; Rong, Fengmin; Wang, Yuanyuan; Qin, Xuena; Wang, Shijin

    2018-02-01

    The study aimed to prospectively investigate whether uterine leiomyoma greater than 10 cm in diameter could be treated with simple ultrasound-guided high-intensity focused ultrasound (USgHIFU) in one-time treatment. A total of 36 patients with 36 symptomatic uterine leiomyoma greater than 10 cm in diameter who underwent simple USgHIFU treatment alone were analysed. Enhanced MRI was performed before and after HIFU treatment, and all patients had follow-up for 6 months after treatment. Symptom severity scores, treatment time, treatment speed, ablation rate, energy effect ratio, uterine leiomyoma regression rate, adverse events, liver and kidney functions, coagulation function and routine blood count were included in the study endpoints. The mean diameter of uterine leiomyoma was 11.2 ± 1.3 cm (10.0-14.3 cm). The median treatment time and treatment speed were 104.0 min (90.0-140.0 min) and 118.8 cm 3  h -1  (86.2-247.1 cm 3  h -1 ), respectively. The ablation rate of uterine leiomyoma was 71.9 ± 20.4% (32.1-100.0%), and the regression rate of uterine leiomyoma was 40.8 ± 7.5% (25.6-59.9%) at 6 months after treatment. The mean symptom severity scores decreased by an average of approximately 8.6 ± 2.3 (5-14) points. There were no significant changes in haemogram and blood chemical indexes of patients, except for the transient elevation of aspartate aminotransferase, total bilirubin and white blood cells after treatment. No serious adverse reactions occurred. According to our preliminary results, simple USgHIFU is a safe and effective single-treatment method of treating uterine leiomyoma greater than 10 cm in diameter and is an almost innocuous alternative therapeutic strategy. Advances in knowledge: The conclusions indicate simple USgHIFU is safe and effective as one-time treatment of uterine leiomyoma greater than 10 cm in diameter, it could be a promising therapeutic strategy.

  12. Theoretical analysis of swelling characteristics of cylindrical uranium dioxide fuel pins with a niobium - 1-percent-zirconium clad

    NASA Technical Reports Server (NTRS)

    Saltsman, J. F.

    1973-01-01

    The relations between clad creep strain and fuel volume swelling are shown for cylindrical UO2 fuel pins with a Nb-1Zr clad. These relations were obtained by using the computer code CYGRO-2. These clad-strain - fuel-volume-swelling relations may be used with any fuel-volume-swelling model, provided the fuel volume swelling is isotropic and independent of the clad restraints. The effects of clad temperature (over a range from 118 to 1642 K (2010 to 2960 R)), pin diameter, clad thickness and central hole size in the fuel have been investigated. In all calculations the irradiation time was 500 hours. The burnup rate was varied.

  13. Reactor design for uniform chemical vapor deposition-grown films without substrate rotation

    DOEpatents

    Wanlass, M.

    1985-02-19

    A quartz reactor vessel for growth of uniform semiconductor films includes a vertical, cylindrical reaction chamber in which a substrate-supporting pedestal provides a horizontal substrate-supporting surface spaced on its perimeter from the chamber wall. A cylindrical confinement chamber of smaller diameter is disposed coaxially above the reaction chamber and receives reaction gas injected at a tangent to the inside chamber wall, forming a helical gas stream that descends into the reaction chamber. In the reaction chamber, the edge of the substrate-supporting pedestal is a separation point for the helical flow, diverting part of the flow over the horizontal surface of the substrate in an inwardly spiraling vortex.

  14. Reactor design for uniform chemical vapor deposition-grown films without substrate rotation

    DOEpatents

    Wanlass, Mark

    1987-01-01

    A quartz reactor vessel for growth of uniform semiconductor films includes a vertical, cylindrical reaction chamber in which a substrate-supporting pedestal provides a horizontal substrate-supporting surface spaced on its perimeter from the chamber wall. A cylindrical confinement chamber of smaller diameter is disposed coaxially above the reaction chamber and receives reaction gas injected at a tangent to the inside chamber wall, forming a helical gas stream that descends into the reaction chamber. In the reaction chamber, the edge of the substrate-supporting pedestal is a separation point for the helical flow, diverting part of the flow over the horizontal surface of the substrate in an inwardly spiraling vortex.

  15. Multi-Disciplinary Research for High Energy Chemical Lasers, Closed-Cycle ElectricOIL Technology

    DTIC Science & Technology

    2007-10-31

    flow iodine from one reservoir and trap it in another. The principal advantage of the hybrid EOIL system is trading a small fixed mass in electrical...rapidly modulate the production of the 02(a) which have motivated investigations into methods to produce significant amounts of 02(a) using flowing...RF power is used for the production of ChC’Ag) in a cylindrical tube (R=2.54 cm and length of 10 cm) with a volume of 200 cm3 at 4.2 torr of pure O2

  16. Er:YLF-laser microperforation of the nail plate for drug delivery

    NASA Astrophysics Data System (ADS)

    Belikov, Andrey V.; Skrypnik, Alexei V.; Sergeev, Andrey N.; Smirnov, Sergey N.; Tavalinskaya, Anastasia D.

    2018-04-01

    Laser microperforation of a human nail plate is an effective method to increase the speed of local drugs delivery in the treatment of nail diseases. In this paper we present the study results of the influence of spatial parameters of Er:YLFlaser- produced microhole array in human nail plate (the diameter of microholes and their packing density) on the rate (vsp) of 0.25 % water-alcohol solution of methylene blue penetration through a single microhole and on the time (Tmp) required for uniform distribution of this drug under the nail plate. In experiments, the diameter of microholes was 220 +/- 10 μm, 300 +/- 10 μm or 350 +/- 10 μm. The packing density for microholes of each of these diameters was 100 μholes/cm2, 400 μholes/cm2 and 950 μholes/cm2. It is shown that vsp is mainly determined by the microhole diameter, and the packing density does not have a significant influence on it. It was experimentally established that the rate vsp is maximal for microholes with 350 μm diameter at packing density of 950 μholes/cm2 and reaches a value of 6.3 μm/s, and the time Tmp is minimal and equal to 180 +/- 10 s at the same values of microhole diameter and packing density.

  17. Further development of chemical vapor deposition process for production of large diameter carbon-base monofilaments

    NASA Technical Reports Server (NTRS)

    Hough, R. L.; Richmond, R. D.

    1974-01-01

    The development of large diameter carbon-base monofilament in the 50 micron to 250 micron diameter range using the chemical vapor deposition process is described. The object of this program was to determine the critical process variables which control monofilament strength, monofilament modulus, and monofilament diameter. It was confirmed that wide scatter in the carbon substrate strength is primarily responsible for the scatter in the monofilament strength. It was also shown through etching experiments that defective substrate surface conditions which can induce low strength modular growth in the monofilament layers are best controlled by processing improvements during the synthesis of the substrate. Modulus was found to be linearily proportional to monofilament boron content. Filament modulus was increased to above 27.8MN/sq cm but only by a considerable increase in monofilament boron content to 60 wt. % or more. Monofilament diameter depended upon dwell time in the synthesis apparatus. A monofilament was prepared using these findings which had the combined properties of a mean U.T.S. of 398,000 N/sq cm, a modulus of 18.9 MN/sq cm (24,000,000 psi), and a diameter of 145 microns. Highest measured strength for this fiber was 451,000 N/sq cm (645,000 psi).

  18. Function of membrane protein in silica nanopores: incorporation of photosynthetic light-harvesting protein LH2 into FSM.

    PubMed

    Oda, Ippei; Hirata, Kotaro; Watanabe, Syoko; Shibata, Yutaka; Kajino, Tsutomu; Fukushima, Yoshiaki; Iwai, Satoshi; Itoh, Shigeru

    2006-01-26

    A high amount of functional membrane protein complex was introduced into a folded-sheet silica mesoporous material (FSM) that has nanometer-size pores of honeycomb-like hexagonal cylindrical structure inside. The photosynthetic light-harvesting complex LH2, which is a typical membrane protein, has a cylindrical structure of 7.3 nm diameter and contains 27 bacteriochlorophyll a and nine carotenoid molecules. The complex captures light energy in the anoxygenic thermophilic purple photosynthetic bacterium Thermochromatium tepidum. The amount of LH2 adsorbed to FSM was determined optically and by the adsorption isotherms of N2. The FSM compounds with internal pore diameters of 7.9 and 2.7 nm adsorbed LH2 at 1.11 and 0.24 mg/mg FSM, respectively, suggesting the high specific affinity of LH2 to the interior of the hydrophobic nanopores with a diameter of 7.9 nm. The LH2 adsorbed to FSM showed almost intact absorption bands of bacteriochlorophylls, and was fully active in the capture and transfer of excitation energy. The LH2 complex inside the FSM showed increased heat stability of the exciton-type absorption band of bacteriochlorophylls (B850), suggesting higher circular symmetry. The environment inside the hydrophobic silica nanopores can be a new matrix for the membrane proteins to reveal their functions. The silica-membrane protein adduct will be useful for the construction of new probes and reaction systems.

  19. Continuous-Flow Electrophoresis of DNA and Proteins in a Two-Dimensional Capillary-Well Sieve.

    PubMed

    Duan, Lian; Cao, Zhen; Yobas, Levent

    2017-09-19

    Continuous-flow electrophoresis of macromolecules is demonstrated using an integrated capillary-well sieve arranged into a two-dimensional anisotropic array on silicon. The periodic array features thousands of entropic barriers, each resulting from an abrupt interface between a 2 μm deep well (channel) and a 70 nm capillary. These entropic barriers owing to two-dimensional confinement within the capillaries are vastly steep in relation to those arising from slits featuring one-dimensional confinement. Thus, the sieving mechanisms can sustain relatively large electric field strengths over a relatively small array area. The sieve rapidly sorts anionic macromolecules, including DNA chains and proteins in native or denatured states, into distinct trajectories according to size or charge under electric field vectors orthogonally applied. The baseline separation is achieved in less than 1 min within a horizontal migration length of ∼1.5 mm. The capillaries are self-enclosed conduits in cylindrical profile featuring a uniform diameter and realized through an approach that avoids advanced patterning techniques. The approach exploits a thermal reflow of a layer of doped glass for shape transformation into cylindrical capillaries and for controllably shrinking the capillary diameter. Lastly, atomic layer deposition of alumina is introduced for the first time to fine-tune the capillary diameter as well as to neutralize the surface charge, thereby suppressing undesired electroosmotic flows.

  20. An experimental study of the reflection from spherical and flat ended cylindrical targets suitable for fetal Doppler performance assessment.

    PubMed

    Preston, R C; Bond, A D

    1997-01-01

    The performance of small-diameter targets suitable for use as oscillating targets for testing the sensitivity of Doppler fetal heartbeat detectors has been systematically studied. Experimental results are presented in the 1.6-3.0 MHz frequency range for the plane-wave reflection loss for a total of 16 targets: spherical balls made of stainless steel; hemispherical-ended rods made of PTFE; and flat-ended rods made of stainless steel, PTFE, polycarbonate, and tungsten carbide. Results show that the fine-structure variation of reflection loss with frequency is greatest in the case of spherical ball targets and least for flat-ended targets. It has been shown that, providing care is taken during manufacture, the reflection loss from a flat-ended target can be predicted using a simple theory based on a plane disc reflector. Tungsten carbide targets consisting of a long rod with a diameter of 1.6 mm tapered down to a cylindrical flat end with a diameter of 0.4, 0.5, and 0.6 mm have been shown to provide reflection losses of between 60 and 40 dB, and to have a smooth variation of reflection loss with frequency. They can also be manufactured in a form that allows no significant interference from the supporting structure and, therefore, are ideal targets to meet the requirements of International Electrotechnical Commission 1266:1995.

  1. Portal vein aneurysm associated with Budd-Chiari syndrome treated with transjugular intrahepatic portosystemic shunt: a case report.

    PubMed

    Tsauo, Jiaywei; Li, Xiao

    2015-03-07

    A 65-year-old woman with Budd-Chiari syndrome (BCS) presented with right upper quadrant pain. A computed tomography (CT) scan showed a saccular aneurysm located at the extrahepatic portal vein main branch measuring 3.2 cm in height and 2.5 cm × 2.4 cm in diameter. The aneurysm was thought to be associated with BCS as there was no preceding history of trauma and it had not been present on Doppler ultrasound examination performed 3 years previously. Because of increasing pain and concern for complications due to aneurysm size, the decision was made to relieve the hepatic venous outflow obstruction. Transjugular intrahepatic portosystemic shunt (TIPS) was created without complications. She had complete resolution of her abdominal pain within 2 d and remained asymptomatic after 1 year of follow-up. CT scans obtained after TIPS showed that the aneurysm had decreased in size to 2.4 cm in height and 2.0 cm × 1.9 cm in diameter at 3 mo, and had further decreased to 1.9 cm in height and 1.6 cm × 1.5 cm in diameter at 1 year.

  2. Minimizing Concentration Effects in Water-Based, Laminar-Flow Condensation Particle Counters

    PubMed Central

    Lewis, Gregory S.; Hering, Susanne V.

    2013-01-01

    Concentration effects in water condensation systems, such as used in the water-based condensation particle counter, are explored through numeric modeling and direct measurements. Modeling shows that the condensation heat release and vapor depletion associated with particle activation and growth lowers the peak supersaturation. At higher number concentrations, the diameter of the droplets formed is smaller, and the threshold particle size for activation is higher. This occurs in both cylindrical and parallel plate geometries. For water-based systems we find that condensational heat release is more important than is vapor depletion. We also find that concentration effects can be minimized through use of smaller tube diameters, or more closely spaced parallel plates. Experimental measurements of droplet diameter confirm modeling results. PMID:24436507

  3. A Study of Cavitation Erosion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiromu Isaka; Masatsugu Tsutsumi; Tadashi Shiraishi

    2002-07-01

    The authors performed experimental study for the purpose of the following two items from a viewpoint of cavitation erosion of a cylindrical orifice in view of a problem at the letdown orifice in PWR (Pressurized Water Reactor). 1. To get the critical cavitation parameter of the cylindrical orifice to establish the design criteria for prevention of cavitation erosion, and 2. to ascertain the erosion rate in such an eventuality that the cavitation erosion occurs with the orifice made of stainless steel with precipitation hardening (17-4-Cu hardening type stainless steel), so that we confirm the appropriateness of the design criteria. Regardingmore » the 1. item, we carried out the cavitation tests to get the critical cavitation parameters inside and downstream of the orifice. The test results showed that the cavitation parameter at inception is independent of the length or the diameter of the orifice. Moreover, the design criteria of cavitation erosion of cylindrical orifices have been established. Regarding the 2. item, we tested the erosion rate under high-pressure conditions. The cavitation erosion actually occurred in the cylindrical orifice at the tests that was strongly resemble to the erosion occurred at the plant. It will be seldom to reproduce resemble cavitation erosion in a cylindrical orifice with the hard material used at plants. We could establish the criteria for preventing the cavitation erosion from the test results. (authors)« less

  4. Dimensional analysis of human saphenous vein grafts: Implications for external mesh support.

    PubMed

    Human, Paul; Franz, Thomas; Scherman, Jacques; Moodley, Lovendran; Zilla, Peter

    2009-05-01

    Constrictive external mesh support of vein grafts was shown to mitigate intimal hyperplasia in animal experiments. To determine the degree of constriction required for the elimination of dimensional irregularities in clinically used vein grafts, a detailed anatomic study of human saphenous veins was conducted. In 200 consecutive patients having coronary artery bypass grafting, harvested saphenous veins (length 34.4 +/- 10.8 cm) were analyzed regarding diameter irregularities, side branch distribution, and microstructure. The mean outer diameter of surgically distended saphenous veins was 4.2 +/- 0.6 mm (men, 4.3 +/- 0.6 mm vs women, 3.9 +/- 0.5 mm; P < .0001). Although the outer diameter significantly decreased over the initial 18 cm (-7.6%; P < .0001), the overall increase between malleolus and thigh was not significant (+11.2%). Smaller-diameter veins (<3.5 mm) had more pronounced diameter fluctuations than larger veins (31.8% +/- 11.0% vs 21.2% +/- 8.8%; P < .0001), with more than 71% of all veins showing caliber changes of more than 20%. There was 1 side branch every 5.4 +/- 4.3 cm, with a significantly higher incidence between 20 and 32 cm from the malleolus (P < .0001 to distal, P < .0004 to proximal). Generally, women had more side branches than men (0.30 +/- 0.15 cm(-1) vs 0.25 +/- 0.12 cm(-1); P = .0190). Thick-walled veins (565.7 +/- 138.4 mum) had a significantly higher number of large side branches (P < .0001), and thin-walled veins (398.7 +/- 123.2 mum) had significantly more small side branches (P < .0001). Pronounced intimal thickening ("cushions") was found in 28% of vessels (119.8 +/- 28.0 mum vs 40.1 +/- 18.2 mum; P < .0001). Although the preferential location of side branches may be addressed by the deliberate discarding of infragenicular vein segments, a diameter constriction of 27% on average would eliminate diameter irregularities in 98% of vein grafts.

  5. Optical CT imaging of solid radiochromic dosimeters in mismatched refractive index solutions using a scanning laser and large area detector.

    PubMed

    Dekker, Kurtis H; Battista, Jerry J; Jordan, Kevin J

    2016-08-01

    The practical use of the PRESAGE® solid plastic dosimeter is limited by the inconvenience of immersing it in high-viscosity oils to achieve refractive index matching for optical computed tomography (CT) scanning. The oils are slow to mix and difficult to clean from surfaces, and the dosimeter rotation can generate dynamic Schlieren inhomogeneity patterns in the reference liquid, limiting the rotational and overall scan speed. Therefore, it would be beneficial if lower-viscosity, water-based solutions with slightly unmatched refractive index could be used instead. The purpose of this work is to demonstrate the feasibility of allowing mismatched conditions when using a scanning laser system with a large acceptance angle detector. A fiducial-based ray path measurement technique is combined with an iterative CT reconstruction algorithm to reconstruct images. A water based surrounding liquid with a low viscosity was selected for imaging PRESAGE® solid dosimeters. Liquid selection was optimized to achieve as high a refractive index as possible while avoiding rotation-induced Schlieren effects. This led to a refractive index mismatch of 6% between liquid and dosimeters. Optical CT scans were performed with a fan-beam scanning-laser optical CT system with a large area detector to capture most of the refracted rays. A fiducial marker placed on the wall of a cylindrical sample occludes a given light ray twice. With knowledge of the rotation angle and the radius of the cylindrical object, the actual internal path of each ray through the dosimeter can be calculated. Scans were performed with 1024 projections of 512 data samples each, and rays were rebinned to form 512 parallel-beam projections. Reconstructions were performed on a 512 × 512 grid using 100 iterations of the SIRT iterative CT algorithm. Proof of concept was demonstrated with a uniformly attenuating solution phantom. PRESAGE® dosimeters (11 cm diameter) were irradiated with Cobalt-60 irradiator to achieve either a uniform dose or a 2-level "step-dose" pattern. With 6% refractive index mismatching, a circular field of view of 85% of the diameter of a cylindrical sample can be reconstructed accurately. Reconstructed images of the test solution phantom were uniform (within 3%) inside this radius. However, the dose responses of the PRESAGE® samples were not spatially uniform, with variations of at least 5% in sensitivity. The variation appears as a "cupping" artifact with less sensitivity in the middle than at the periphery of the PRESAGE® cylinder. Polarization effects were also detected for these samples. The fiducial-based ray path measurement scheme, coupled with an iterative reconstruction algorithm, enabled optical CT scanning of PRESAGE® dosimeters immersed in mismatched refractive index solutions. However, improvements to PRESAGE® dose response uniformity are required.

  6. Ecological Importance of Small-Diameter Trees to the Structure, Diversity and Biomass of a Tropical Evergreen Forest at Rabi, Gabon.

    PubMed

    Memiaghe, Hervé R; Lutz, James A; Korte, Lisa; Alonso, Alfonso; Kenfack, David

    2016-01-01

    Tropical forests have long been recognized for their biodiversity and ecosystem services. Despite their importance, tropical forests, and particularly those of central Africa, remain understudied. Until recently, most forest inventories in Central Africa have focused on trees ≥10 cm in diameter, even though several studies have shown that small-diameter tree population may be important to demographic rates and nutrient cycling. To determine the ecological importance of small-diameter trees in central African forests, we used data from a 25-ha permanent plot that we established in the rainforest of Gabon to study the diversity and dynamics of these forests. Within the plot, we censused 175,830 trees ≥1 cm dbh from 54 families, 192 genera, and 345 species. Average tree density was 7,026 trees/ha, basal area 31.64 m2/ha, and above-ground biomass 369.40 Mg/ha. Fabaceae, Ebenaceae and Euphorbiaceae were the most important families by basal area, density and above-ground biomass. Small-diameter trees (1 cm ≥ dbh <10 cm) comprised 93.7% of the total tree population, 16.5% of basal area, and 4.8% of the above-ground biomass. They also had diversity 18% higher at family level, 34% higher at genus level, and 42% higher at species level than trees ≥10 cm dbh. Although the relative contribution of small-diameter trees to biomass was comparable to other forests globally, their contribution to forest density, and diversity was disproportionately higher. The high levels of diversity within small-diameter classes may give these forests high levels of structural resilience to anthropogenic/natural disturbance and a changing climate.

  7. Ecological Importance of Small-Diameter Trees to the Structure, Diversity and Biomass of a Tropical Evergreen Forest at Rabi, Gabon

    PubMed Central

    Memiaghe, Hervé R.; Lutz, James A.; Korte, Lisa; Alonso, Alfonso; Kenfack, David

    2016-01-01

    Tropical forests have long been recognized for their biodiversity and ecosystem services. Despite their importance, tropical forests, and particularly those of central Africa, remain understudied. Until recently, most forest inventories in Central Africa have focused on trees ≥10 cm in diameter, even though several studies have shown that small-diameter tree population may be important to demographic rates and nutrient cycling. To determine the ecological importance of small-diameter trees in central African forests, we used data from a 25-ha permanent plot that we established in the rainforest of Gabon to study the diversity and dynamics of these forests. Within the plot, we censused 175,830 trees ≥1 cm dbh from 54 families, 192 genera, and 345 species. Average tree density was 7,026 trees/ha, basal area 31.64 m2/ha, and above-ground biomass 369.40 Mg/ha. Fabaceae, Ebenaceae and Euphorbiaceae were the most important families by basal area, density and above-ground biomass. Small-diameter trees (1 cm ≥ dbh <10 cm) comprised 93.7% of the total tree population, 16.5% of basal area, and 4.8% of the above-ground biomass. They also had diversity 18% higher at family level, 34% higher at genus level, and 42% higher at species level than trees ≥10 cm dbh. Although the relative contribution of small-diameter trees to biomass was comparable to other forests globally, their contribution to forest density, and diversity was disproportionately higher. The high levels of diversity within small-diameter classes may give these forests high levels of structural resilience to anthropogenic/natural disturbance and a changing climate. PMID:27186658

  8. Influence of multiple brain metastases’ size and number on the quality of SRS - VMAT dose delivery

    NASA Astrophysics Data System (ADS)

    Prentou, G.; Koutsouveli, E.; Pantelis, E.; Papagiannis, P.; Georgiou, E.; Karaiskos, P.

    2017-11-01

    Stereotactic radiosurgery with volumetric modulated arc therapy (SRS-VMAT) has recently been introduced for treatment of multiple brain metastases with a single isocenter. The technique’s high efficiency is nevertheless dependent of metastatic tumors’ characteristics such as size and number. In this work the impact of the metastases’ size and number on the plan quality indices clinically used for plan evaluation and acceptance is investigated. Fifteen targets with a diameter of 1 cm and average volume of 0.7 cm3 and ten targets with a diameter of 2 cm and average volume of 6.5 cm3 were contoured on an anonymized patient CT dataset, in Monaco (Elekta) treatment planning system. VMAT plans for different target volumes (1 and 2 cm in diameter) and various target numbers (1-15) were generated using four non-coplanar arcs and the Agility (Elekta) linear accelerator (5 mm MLC width) using a Monte Carlo dose calculation algorithm and 1mm dose calculation grid resolution. Conformity index (CI), gradient index (GI) and heterogeneity index (HI) were determined for each target. High quality plans were created for both 1 cm and 2 cm in diameter targets for limited (<6) number of targets per plan. For increased number of irradiated targets (>6) both CI and GI, clinically used for plan evaluation and acceptance, were found to deteriorate.

  9. Preliminary Investigations on Therapy Thresholds for Laser Dosimetry, Cryogen Spray Cooling Duration, and Treatment Cycles for Laser Cartilage Reshaping in the New Zealand White Rabbit Auricle

    PubMed Central

    Chlebicki, Cara A.; Protsenko, Dmitry E.; Wong, Brian J.

    2014-01-01

    Previous studies have demonstrated the feasibility of laser irradiation (λ=1.45 μm) in tandem with cryogen spray cooling (CSC) to reshape rabbit auricular cartilage using total energy density of 14 J/cm2. The aim of this study was to further explore and identify the dosimetry parameter space for laser output energy, CSC duration, and treatment cycles required to achieve shape change while limiting skin and cartilage injury. Ten New Zealand white rabbits were treated with the 1.45 μm diode laser combined with cryogen spray cooling (Candela Smoothbeam™, Candela Co., Wayland, MA). The ear's central portion was bent around a cylindrical jig and irradiated in consecutive spots of 6 mm diameter (13 J/cm2 or 14 J/cm2 per spot) along 3 rows encompassing the bend. CSC was delivered during irradiation in cycles consisting of 25-35 ms. At thin and thick portions of the ear, 4-7 and 6-10 treatment cycles were delivered, respectively. After surgery, ears were examined and splinted for 6 weeks. Treatment parameters resulting in acceptable (Grades 1 & 2) and unacceptable (Grade 3) skin injuries for thick and thin regions were identified and shape change was observed. Confocal and histological analysis of cartilage tissue revealed several outcomes correlating to laser dosimetry, CSC duration, and treatment cycles. These outcomes included expansion of cartilage layers (thickening), partial cartilage injuries, and full thickness cartilage injuries. We determined therapy thresholds for laser output energy, cryogen spray cooling duration, and treatment cycles in the rabbit auricular model. These parameters are a starting point for future clinical procedures aimed at correcting external ear deformities. PMID:24202858

  10. Dose evaluation of an NIPAM polymer gel dosimeter using gamma index

    NASA Astrophysics Data System (ADS)

    Chang, Yuan-Jen; Lin, Jing-Quan; Hsieh, Bor-Tsung; Yao, Chun-Hsu; Chen, Chin-Hsing

    2014-11-01

    An N-isopropylacrylamide (NIPAM) polymer gel dosimeter has great potential in clinical applications. However, its three-dimensional dose distribution must be assessed. In this work, a quantitative evaluation of dose distributions was performed to evaluate the NIPAM polymer gel dosimeter using gamma analysis. A cylindrical acrylic phantom filled with NIPAM gel measuring 10 cm (diameter) by 10 cm (height) by 3 mm (thickness) was irradiated by a 4×4 cm2 square light field. The irradiated gel phantom was scanned using an optical computed tomography (optical CT) scanner (OCTOPUS™, MGS Research, Inc., Madison, CT, USA) at 1 mm resolution. The projection data were transferred to an image reconstruction program, which was written using MATLAB (The MathWorks, Natick, MA, USA). The program reconstructed the image of the optical density distribution using the algorithm of a filter back-projection. Three batches of replicated gel phantoms were independently measured. The average uncertainty of the measurements was less than 1%. The gel was found to have a high degree of spatial uniformity throughout the dosimeter and good temporal stability. A comparison of the line profiles of the treatment planning system and of the data measured by optical CT showed that the dose was overestimated in the penumbra region because of two factors. The first is light scattering due to changes in the refractive index at the edge of the irradiated field. The second is the edge enhancement caused by free radical diffusion. However, the effect of edge enhancement on the NIPAM gel dosimeter is not as significant as that on the BANG gel dosimeter. Moreover, the dose uncertainty is affected by the inaccuracy of the gel container positioning process. To reduce the uncertainty of 3D dose distribution, improvements in the gel container holder must be developed.

  11. Design of an exposure chamber to test samplers used in the evaluation of personal exposure to nanoparticles

    NASA Astrophysics Data System (ADS)

    Amin, R.; Izadi, H.; Quémerais, B.

    2015-05-01

    The aim of this study was to design a laboratory size exposure chamber for the testing of samplers used to collect personal exposure samples for nanoparticles. A polyethylene cylindrical container with a diameter of 42 cm and height of 60 cm was used as the testing chamber. The chamber was divided into 2 parts by an aluminium honey comb. Particles generated using a 1 jet Collison nebulizer (BGI) operating at a flow rate of 4L/min were inserted into the chamber via a tube located near to the top of the chamber. A heater was inserted just after the nebulizer to avoid condensation of water in the tubing, and dilution air, running at 10L/min was inserted just after the heater. As particle charge can dramatically affect sampling a particle neutralizer was attached to the generation system so as to neutralize the particles before they enter the chamber. A diffusion dryer was used to remove any water from the air stream prior to enter the chamber. A fan was used to mix and distribute the generated particles. After generation and mixing, the particles passed through the aluminium honeycomb which is essential to eliminate any turbulent or unwanted air flow. Six sampling ports along with a pressure gauge were placed on the walls 15 cm from the bottom of the chamber. The pressure gauge was added to ensure the desired pressure is achieved during sampling. The sampling ports allowed for the connection of five samplers and sampling pumps as well as the connection of an ultrafine particle counter. The exposure chamber was developed to assess various samplers for carbon nanotubes and cellulose nanocrystals. Results showed that the chamber was working properly and that mixing was sufficiently uniform to test samplers.

  12. Comparison of experimental and theoretical normal-force distributions (including Reynolds number effects) on an ogive-cylinder body at Mach number 1.98

    NASA Technical Reports Server (NTRS)

    Perkins, Edward W; Jorgensen, Leland H

    1956-01-01

    Effects of Reynolds number and angle of attack on the pressure distribution and normal-force characteristics of a body of revolution consisting of a fineness ratio 3 ogival nose tangent to a cylindrical afterbody 7 diameters long have been determined. The test Mach number was 1.98 and the angle-of-attack range from 0 degree to 20 degrees. The Reynolds numbers, based on body diameter, were 0.15 x 10(6) and 0.45 x 10(6). The experimental results are compared with theory.

  13. Hydrophilic Electrode For An Alkaline Electrochemical Cell, And Method Of Manufacture

    DOEpatents

    Senyarich, Stephane; Cocciantelli, Jean-Michel

    2000-03-07

    A negative electrode for an alkaline electrochemical cell. The electrode comprises an active material and a hydrophilic agent constituted by small cylindrical rods of polyolefin provided with hydrophilic groups. The mean length of the rods is less than 50 microns and the mean diameter thereof is less than 20 microns. A method of manufacturing a negative electrode in which hydrophilic rods are made by fragmenting long polyolefin fibers having a mean diameter of less than 20 microns by oxidizing them, with the rods being mixed with the active material and the mixture being applied to a current conductor.

  14. Investigation of Some Wake Vortex Characteristics of an Inclined Ogive-Cylinder Body at Mach Number 2

    NASA Technical Reports Server (NTRS)

    Jorgensen, Leland H; Perkins, Edward W

    1958-01-01

    For a body consisting of a fineness-ratio-3 ogival nose tangent to a cylindrical afterbody 7.3 diameters long, pitot-pressure distributions in the flow field, pressure distributions over the body, and downwash distributions along a line through the vortex centers have been measured for angles of attack to 20 degrees. The Reynolds numbers, based on body diameter, were 0.15 x 10 to the 6th power and 0.44 x 10 to the 6th power. Comparisons of computed and measured vortex paths and downwash distributions are made. (author)

  15. A high-performance magnetic shield with large length-to-diameter ratio.

    PubMed

    Dickerson, Susannah; Hogan, Jason M; Johnson, David M S; Kovachy, Tim; Sugarbaker, Alex; Chiow, Sheng-wey; Kasevich, Mark A

    2012-06-01

    We have demonstrated a 100-fold improvement in the magnetic field uniformity on the axis of a large aspect ratio, cylindrical, mumetal magnetic shield by reducing discontinuities in the material of the shield through the welding and re-annealing of a segmented shield. The three-layer shield reduces Earth's magnetic field along an 8 m region to 420 μG (rms) in the axial direction, and 460 and 730 μG (rms) in the two transverse directions. Each cylindrical shield is a continuous welded tube which has been annealed after manufacture and degaussed in the apparatus. We present both experiments and finite element analysis that show the importance of uniform shield material for large aspect ratio shields, favoring a welded design over a segmented design. In addition, we present finite element results demonstrating the smoothing of spatial variations in the applied magnetic field by cylindrical magnetic shields. Such homogenization is a potentially useful feature for precision atom interferometric measurements.

  16. Prosthetic helping hand

    NASA Technical Reports Server (NTRS)

    Vest, Thomas W. (Inventor); Carden, James R. (Inventor); Norton, William E. (Inventor); Belcher, Jewell G. (Inventor)

    1992-01-01

    A prosthetic device for below-the-elbow amputees, having a C-shaped clamping mechanism for grasping cylindrical objects, is described. The clamping mechanism is pivotally mounted to a cuff that fits on the amputee's lower arm. The present invention is utilized by placing an arm that has been amputated below the elbow into the cuff. The clamping mechanism then serves as a hand whenever it becomes necessary for the amputee to grasp a cylindrical object such as a handle, a bar, a rod, etc. To grasp the cylindrical object, the object is jammed against the opening in the C-shaped spring, causing the spring to open, the object to pass to the center of the spring, and the spring to snap shut behind the object. Various sizes of clamping mechanisms can be provided and easily interchanged to accommodate a variety of diameters. With the extension that pivots and rotates, the clamping mechanism can be used in a variety of orientations. Thus, this invention provides the amputee with a clamping mechanism that can be used to perform a number of tasks.

  17. Effect of lung and target density on small-field dose coverage and PTV definition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higgins, Patrick D., E-mail: higgi010@umn.edu; Ehler, Eric D.; Cho, Lawrence C.

    We have studied the effect of target and lung density on block margin for small stereotactic body radiotherapy (SBRT) targets. A phantom (50 × 50 × 50 cm{sup 3}) was created in the Pinnacle (V9.2) planning system with a 23-cm diameter lung region of interest insert. Diameter targets of 1.6, 2.0, 3.0, and 4.0 cm were placed in the lung region of interest and centered at a physical depth of 15 cm. Target densities evaluated were 0.1 to 1.0 g/cm{sup 3}, whereas the surrounding lung density was varied between 0.05 and 0.6 g/cm{sup 3}. A dose of 100 cGy wasmore » delivered to the isocenter via a single 6-MV field, and the ratio of the average dose to points defining the lateral edges of the target to the isocenter dose was recorded for each combination. Field margins were varied from none to 1.5 cm in 0.25-cm steps. Data obtained in the phantom study were used to predict planning treatment volume (PTV) margins that would match the clinical PTV and isodose prescription for a clinical set of 39 SBRT cases. The average internal target volume (ITV) density was 0.73 ± 0.17, average local lung density was 0.33 ± 0.16, and average ITV diameter was 2.16 ± 0.8 cm. The phantom results initially underpredicted PTV margins by 0.35 cm. With this offset included in the model, the ratio of predicted-to-clinical PTVs was 1.05 ± 0.32. For a given target and lung density, it was found that treatment margin was insensitive to target diameter, except for the smallest (1.6-cm diameter) target, for which the treatment margin was more sensitive to density changes than the larger targets. We have developed a graphical relationship for block margin as a function of target and lung density, which should save time in the planning phase by shortening the design of PTV margins that can satisfy Radiation Therapy Oncology Group mandated treatment volume ratios.« less

  18. High-powered microwave ablation with a small-gauge, gas-cooled antenna: initial ex vivo and in vivo results.

    PubMed

    Lubner, Meghan G; Hinshaw, J Louis; Andreano, Anita; Sampson, Lisa; Lee, Fred T; Brace, Christopher L

    2012-03-01

    To evaluate the performance of a gas-cooled, high-powered microwave system. Investigators performed 54 ablations in ex vivo bovine livers using three devices-a single 17-gauge cooled radiofrequency(RF) electrode; a cluster RF electrode; and a single 17-gauge, gas-cooled microwave (MW) antenna-at three time points (n = 6 at 4 minutes, 12 minutes, and 16 minutes). RF power was applied using impedance-based pulsing with maximum 200 W generator output. MW power of 135 W at 2.45 GHz was delivered continuously. An approved in vivo study was performed using 13 domestic pigs. Hepatic ablations were performed using single applicators and the above-mentioned MW and RF generator systems at treatment times of 2 minutes (n = 7 MW, n = 6 RF), 5 minutes (n = 23 MW, n = 8 RF), 7 minutes (n = 11 MW, n = 6 RF), and 10 minutes (n = 7 MW, n = 9 RF). Mean transverse diameter and length of the ablation zones were compared using analysis of variance (ANOVA) with post-hoc t tests and Wilcoxon rank-sum tests. Single ex vivo MW ablations were larger than single RF ablations at all time points (MW mean diameter range 3.5-4.8 cm 4-16 minutes; RF mean diameter range 2.6-3.1 cm 4-16 minutes) (P < .05). There was no difference in mean diameter between cluster RF and MW ablations (RF 3.3-4.4 cm 4-16 minutes; P = .4-.9). In vivo lesion diameters for MW (and RF) were as follows: 2.6 cm ± 0.72 (RF 1.5 cm ± 0.14), 3.6 cm ± 0.89 (RF 2.0 cm ± 0.4), 3.4 cm ± 0.87 (RF 1.8 cm ± 0.23), and 3.8 cm ± 0.74 (RF 2.1 cm ± 0.3) at 2 minutes, 5 minutes, 7 minutes, and 10 minutes (P < .05 all time points). Gas-cooled, high-powered MW ablation allows the generation of large ablation zones in short times. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  19. SU-E-T-598: The Effects of Arm Speed for Quality Assurance and Commissioning Measurements in Rectangular and Cylindrical Scanners

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakhtiari, M; Schmitt, J

    2014-06-01

    Purpose: Cylindrical and rectangular scanning water tanks are examined with different scanning speeds to investigate the TG-106 criteria and the errors induced in the measurements. Methods: Beam profiles were measured in a depth of R50 for a low-energy electron beam (6 MeV) using rectangular and cylindrical tanks. The speeds of the measurements (arm movement) were varied in different profile measurements. Each profile was measured with a certain speed to obtain the average and standard deviation as a parameter for investigating the reproducibility and errors. Results: At arm speeds of ∼0.8 mm/s the errors were as large as 2% and 1%more » with rectangular and cylindrical tanks, respectively. The errors for electron beams and for photon beams in other depths were within the TG-106 criteria of 1% for both tank shapes. Conclusion: The measurements of low-energy electron beams in a depth of R50, as an extreme case scenario, are sensitive to the speed of the measurement arms for both rectangular and cylindrical tanks. The measurements in other depths, for electron beams and photon beams, with arm speeds of less than 1 cm/s are within the TG-106 criteria. An arm speed of 5 mm/s appeared to be optimal for fast and accurate measurements for both cylindrical and rectangular tanks.« less

  20. Ceramic backup ring prevents undesirable weld-metal buildup

    NASA Technical Reports Server (NTRS)

    Leonard, G. E.

    1971-01-01

    Removable ceramic backup material butted against weld zone back prevents weld metal buildup at that site. Method is successful with manual tungsten-inert gas /TIG/ welding of 316 corrosion resistant steel /CRES/ pieces with 0.76 cm throat diameter and 1.57 cm pipe internal diameter.

  1. Method of making monodisperse nanoparticles

    DOEpatents

    Fan, Hongyon; Sun, Zaicheng

    2012-10-16

    A method of making particles of either spherical or cylindrical geometry with a characteristic diameter less than 50 nanometers by mixing at least one structure directing agent dissolved in a solvent with at least one amphiphilic block copolymer dissolved in a solvent to make a solution containing particles, where the particles can be subsequently separated and dispersed in a solvent of choice.

  2. Novel fuelbed characteristics associated with mechanical mastication treatments in northern California and south-western Oregon, USA

    Treesearch

    Jeffrey M. Kane; J. Morgan Varner; Eric E. Knapp

    2009-01-01

    Mechanically masticated fuelbeds are distinct from natural or logging slash fuelbeds, with different particle size distributions, bulk density, and particle shapes, leading to challenges in predicting fire behavior and effects. Our study quantified some physical properties of fuel particles (e.g. squared quadratic mean diameter, proportion of non-cylindrical particles...

  3. 30 CFR 18.66 - Tests of windows and lenses.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of windows and lenses. 18.66 Section 18... Tests § 18.66 Tests of windows and lenses. (a) Impact tests. A 4-pound cylindrical weight with a 1-inch-diameter hemispherical striking surface shall be dropped (free fall) to strike the window or lens in its...

  4. A study on the imaging characteristics of Gold nanoparticles as a contrast agent in X-ray computed tomography

    NASA Astrophysics Data System (ADS)

    Mesbahi, Asghar; Famouri, Fatemeh; Ahar, Mohammad Johari; Ghaffari, Maryam Olade; Ghavami, Seyed Mostafa

    2017-03-01

    Aim: In the current study, some imaging characteristics of AuNPs were quantitatively analyzed and compared with two conventional contrast media (CM) including Iodine and Gadolinium by using of a cylindrical phantom. Methods: AuNPs were synthesized with the mean diameter of 16 nm and were equalized to the concentration of 0.5, 1, 2 and 4 mg/mL in the same volumes. A cylindrical phantom resembling the head and neck was fabricated and drilled to contain small tubes filled with Iodine, Gadolinium, and AuNPs as contrast media. The phantom was scanned in different exposure techniques and CT numbers of three studied contrast media inside test tubes were measured in terms of Hounsfield Unit (HU). The imaging parameters of the noise and contrast to noise ratios (CNR) were calculated for all studied CMs. Results: AuNPs showed 128% and 166% higher CT number in comparison with Iodine and Gadolinium respectively. Also, Iodine had a greater CT number than Gadolinium for the same exposure techniques and concentration. The maximum CT number for AuNPs and studied contrast materials was obtained at the highest mAs and the lowest tube potential. The maximum CT number were 1033±11 (HU) for AuNP, 565±10 (HU) for Iodine, 458±11 for Gadolinium. Moreover, the maximum CNRs of 433±117, 203±53, 145±37 were found for AuNPs, Iodine and Gadolinium respectively. Conclusion: The contrast agent based on AuNPs showed higher imaging quality in terms of contrast and noise relative to other iodine and gadolinium based contrast media in X-ray computed tomography. Application of the AuNPs as a contrast medium in x-ray CT is recommended.

  5. Nuclear reactor heat transport system component low friction support system

    DOEpatents

    Wade, Elman E.

    1980-01-01

    A support column for a heavy component of a liquid metal fast breeder reactor heat transport system which will deflect when the pipes leading coolant to and from the heavy component expand or contract due to temperature changes includes a vertically disposed pipe, the pipe being connected to the heavy component by two longitudinally spaced cycloidal dovetail joints wherein the distal end of each of the dovetails constitutes a part of the surface of a large diameter cylinder and the centerlines of these large diameter cylinders intersect at right angles and the pipe being supported through two longitudinally spaced cycloidal dovetail joints wherein the distal end of each of the dovetails constitutes a part of the surface of a large diameter cylinder and the centerlines of these large diameter cylinders intersect at right angles, each of the cylindrical surfaces bearing on a flat and horizontal surface.

  6. Comparison of Epidermal/Dermal Damage Between the Long-Pulsed 1064 nm Nd:YAG and 755 nm Alexandrite Lasers Under Relatively High Fluence Conditions: Quantitative and Histological Assessments

    PubMed Central

    Lee, Ju Hwan; Park, So Ra; Jo, Jeong Ho; Park, Sung Yun; Seo, Young Kwon

    2014-01-01

    Abstract Objective: The purpose of this study was to compare degrees of epidermal/dermal tissue damage quantitatively and histologically after laser irradiation, to find ideal treatment conditions with relatively high fluence for skin rejuvenation. Background data: A number of recent studies have evaluated the clinical efficacy and safety of therapeutic lasers under relatively low fluence conditions. Methods: We transmitted the long-pulsed 1064 nm Nd:YAG and 755 nm Alexandrite lasers into pig skin according to different fluences and spot diameters, and estimated epidermal/dermal temperatures. Pig skin specimens were stained with hematoxylin and eosin for histological assessments. The fluence conditions comprised 26, 30, and 36 J/cm2, and the spot diameter conditions were 5, 8, and 10 mm. Pulse duration was 30 ms for all experiments. Results: Both lasers produced reliable thermal damage on the dermis without any serious epidermal injuries, under relatively high fluence conditions. The 1064 nm laser provided more active fibrous formations than the 755 nm laser, while higher risks for tissue damages simultaneously occurred. Conclusions: The ideal treatment conditions for skin rejuvenation were 8 mm diameter with 30 J/cm2 and 10 mm diameter with 26 J/cm2 for the 1064 nm laser, and 8 mm diameter with 36 J/cm2 and 10 mm diameter with 26 J/cm2 for the 755 nm laser. PMID:24992273

  7. Long-term diameter growth for trees in the Cinnamon Bay Watershed

    Treesearch

    Peter L. Weaver

    2009-01-01

    From 1983 to 2008, the mean annual diameter growth (MAI) for 1,402 surviving stems of 62 species in the Cinnamon Bay watershed was 0.08¡À0.002 cm yr-1. Long-term MAI ranged from 0.02 cm yr-1 for Randia aculeata to 0.23 cm yr-1 for Inga laurina. Of the 30 species with ¡Ý8 surviving stems, eight averaged ¡Ý0.10 cm yr-1. Hurricane Hugo in 1989, Hurricane Marilyn in 1995,...

  8. Open-Ended Coaxial Dielectric Probe Effective Penetration Depth Determination.

    PubMed

    Meaney, Paul M; Gregory, Andrew P; Seppälä, Jan; Lahtinen, Tapani

    2016-03-01

    We have performed a series of experiments which demonstrate the effect of open-ended coaxial diameter on the depth of penetration. We used a two layer configuration of a liquid and movable cylindrical piece of either Teflon or acrylic. The technique accurately demonstrates the depth in a sample for which a given probe diameter provides a reasonable measure of the bulk dielectric properties for a heterogeneous volume. In addition we have developed a technique for determining the effective depth for a given probe diameter size. Using a set of simulations mimicking four 50 Ω coaxial cable diameters, we demonstrate that the penetration depth in both water and saline has a clear dependence on probe diameter but is remarkably uniform over frequency and with respect to the intervening liquid permittivity. Two different 50 Ω commercial probes were similarly tested and confirm these observations. This result has significant implications to a range of dielectric measurements, most notably in the area of tissue property studies.

  9. Open-Ended Coaxial Dielectric Probe Effective Penetration Depth Determination

    PubMed Central

    Meaney, Paul M.; Gregory, Andrew P.; Seppälä, Jan; Lahtinen, Tapani

    2016-01-01

    We have performed a series of experiments which demonstrate the effect of open-ended coaxial diameter on the depth of penetration. We used a two layer configuration of a liquid and movable cylindrical piece of either Teflon or acrylic. The technique accurately demonstrates the depth in a sample for which a given probe diameter provides a reasonable measure of the bulk dielectric properties for a heterogeneous volume. In addition we have developed a technique for determining the effective depth for a given probe diameter size. Using a set of simulations mimicking four 50 Ω coaxial cable diameters, we demonstrate that the penetration depth in both water and saline has a clear dependence on probe diameter but is remarkably uniform over frequency and with respect to the intervening liquid permittivity. Two different 50 Ω commercial probes were similarly tested and confirm these observations. This result has significant implications to a range of dielectric measurements, most notably in the area of tissue property studies. PMID:27346890

  10. Stripping the Sheath From Stranded Cables

    NASA Technical Reports Server (NTRS)

    Prisk, A. L.; Rotta, J. W.

    1985-01-01

    Device similar to tubing cutter removes tough plastic cover. Insulation stripper is 3 in. (7.6 cm) long and 1.5 (3.8 cm) in diameter. Two rollers are small-diameter bearings. Cutter blade journaled for rotation between pair of similar bearings. Bearings either pin or ball types of suitable dimensions.

  11. Quantifying bone thickness, light transmission, and contrast interrelationships in transcranial photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Lediju Bell, Muyinatu A.; Ostrowski, Anastasia K.; Li, Ke; Kaanzides, Peter; Boctor, Emad

    2015-03-01

    We previously introduced photoacoustic imaging to detect blood vessels surrounded by bone and thereby eliminate the deadly risk of carotid artery injury during endonasal, transsphenoidal surgeries. Light would be transmitted through an optical fiber attached to the surgical drill, while a transcranial probe placed on the temporal region of the skull receives photoacoustic signals. This work quantifies changes in photoacoustic image contrast as the sphenoid bone is drilled. Frontal bone from a human adult cadaver skull was cut into seven 3 cm x 3 cm chips and sanded to thicknesses ranging 1-4 mm. For 700-940 nm wavelengths, the average optical transmission through these specimens increased from 19% to 44% as bone thickness decreased, with measurements agreeing with Monte Carlo simulations within 5%. These skull specimens were individually placed in the optical pathway of a 3.5 mm diameter, cylindrical, vessel-mimicking photoacoustic target, as the laser wavelength was varied between 700-940 nm. The mean optical insertion loss and photoacoustic image contrast loss due to the bone specimens were 56-80% and 46-79%, respectively, with the majority of change observed when the bone was <=2 mm thick. The decrease in contrast is directly proportional to insertion loss over this thickness range by factors of 0.8-1.1 when multiple wavelengths are considered. Results suggest that this proportional relationship may be used to determine the amount of bone that remains to be drilled when the thickness is 2 mm or less.

  12. Electronic noise in CT detectors: Impact on image noise and artifacts.

    PubMed

    Duan, Xinhui; Wang, Jia; Leng, Shuai; Schmidt, Bernhard; Allmendinger, Thomas; Grant, Katharine; Flohr, Thomas; McCollough, Cynthia H

    2013-10-01

    The objective of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.

  13. Preparing silica aerogel monoliths via a rapid supercritical extraction method.

    PubMed

    Carroll, Mary K; Anderson, Ann M; Gorka, Caroline A

    2014-02-28

    A procedure for the fabrication of monolithic silica aerogels in eight hours or less via a rapid supercritical extraction process is described. The procedure requires 15-20 min of preparation time, during which a liquid precursor mixture is prepared and poured into wells of a metal mold that is placed between the platens of a hydraulic hot press, followed by several hours of processing within the hot press. The precursor solution consists of a 1.0:12.0:3.6:3.5 x 10(-3) molar ratio of tetramethylorthosilicate (TMOS):methanol:water:ammonia. In each well of the mold, a porous silica sol-gel matrix forms. As the temperature of the mold and its contents is increased, the pressure within the mold rises. After the temperature/pressure conditions surpass the supercritical point for the solvent within the pores of the matrix (in this case, a methanol/water mixture), the supercritical fluid is released, and monolithic aerogel remains within the wells of the mold. With the mold used in this procedure, cylindrical monoliths of 2.2 cm diameter and 1.9 cm height are produced. Aerogels formed by this rapid method have comparable properties (low bulk and skeletal density, high surface area, mesoporous morphology) to those prepared by other methods that involve either additional reaction steps or solvent extractions (lengthier processes that generate more chemical waste).The rapid supercritical extraction method can also be applied to the fabrication of aerogels based on other precursor recipes.

  14. Preparing Silica Aerogel Monoliths via a Rapid Supercritical Extraction Method

    PubMed Central

    Gorka, Caroline A.

    2014-01-01

    A procedure for the fabrication of monolithic silica aerogels in eight hours or less via a rapid supercritical extraction process is described. The procedure requires 15-20 min of preparation time, during which a liquid precursor mixture is prepared and poured into wells of a metal mold that is placed between the platens of a hydraulic hot press, followed by several hours of processing within the hot press. The precursor solution consists of a 1.0:12.0:3.6:3.5 x 10-3 molar ratio of tetramethylorthosilicate (TMOS):methanol:water:ammonia. In each well of the mold, a porous silica sol-gel matrix forms. As the temperature of the mold and its contents is increased, the pressure within the mold rises. After the temperature/pressure conditions surpass the supercritical point for the solvent within the pores of the matrix (in this case, a methanol/water mixture), the supercritical fluid is released, and monolithic aerogel remains within the wells of the mold. With the mold used in this procedure, cylindrical monoliths of 2.2 cm diameter and 1.9 cm height are produced. Aerogels formed by this rapid method have comparable properties (low bulk and skeletal density, high surface area, mesoporous morphology) to those prepared by other methods that involve either additional reaction steps or solvent extractions (lengthier processes that generate more chemical waste).The rapid supercritical extraction method can also be applied to the fabrication of aerogels based on other precursor recipes. PMID:24637334

  15. Multimaterial Decomposition Algorithm for the Quantification of Liver Fat Content by Using Fast-Kilovolt-Peak Switching Dual-Energy CT: Experimental Validation.

    PubMed

    Hyodo, Tomoko; Hori, Masatoshi; Lamb, Peter; Sasaki, Kosuke; Wakayama, Tetsuya; Chiba, Yasutaka; Mochizuki, Teruhito; Murakami, Takamichi

    2017-02-01

    Purpose To assess the ability of fast-kilovolt-peak switching dual-energy computed tomography (CT) by using the multimaterial decomposition (MMD) algorithm to quantify liver fat. Materials and Methods Fifteen syringes that contained various proportions of swine liver obtained from an abattoir, lard in food products, and iron (saccharated ferric oxide) were prepared. Approval of this study by the animal care and use committee was not required. Solid cylindrical phantoms that consisted of a polyurethane epoxy resin 20 and 30 cm in diameter that held the syringes were scanned with dual- and single-energy 64-section multidetector CT. CT attenuation on single-energy CT images (in Hounsfield units) and MMD-derived fat volume fraction (FVF; dual-energy CT FVF) were obtained for each syringe, as were magnetic resonance (MR) spectroscopy measurements by using a 1.5-T imager (fat fraction [FF] of MR spectroscopy). Reference values of FVF (FVF ref ) were determined by using the Soxhlet method. Iron concentrations were determined by inductively coupled plasma optical emission spectroscopy and divided into three ranges (0 mg per 100 g, 48.1-55.9 mg per 100 g, and 92.6-103.0 mg per 100 g). Statistical analysis included Spearman rank correlation and analysis of covariance. Results Both dual-energy CT FVF (ρ = 0.97; P < .001) and CT attenuation on single-energy CT images (ρ = -0.97; P < .001) correlated significantly with FVF ref for phantoms without iron. Phantom size had a significant effect on dual-energy CT FVF after controlling for FVF ref (P < .001). The regression slopes for CT attenuation on single-energy CT images in 20- and 30-cm-diameter phantoms differed significantly (P = .015). In sections with higher iron concentrations, the linear coefficients of dual-energy CT FVF decreased and those of MR spectroscopy FF increased (P < .001). Conclusion Dual-energy CT FVF allows for direct quantification of fat content in units of volume percent. Dual-energy CT FVF was larger in 30-cm than in 20-cm phantoms, though the effect of object size on fat estimation was less than that of CT attenuation on single-energy CT images. In the presence of iron, dual-energy CT FVF led to underestimateion of FVF ref to a lesser degree than FF of MR spectroscopy led to overestimation of FVF ref . © RSNA, 2016 Online supplemental material is available for this article.

  16. Modeling light scattering in the shadow region behind thin cylinders for diameter analysis

    NASA Astrophysics Data System (ADS)

    Blohm, Werner

    2018-03-01

    In this paper, the scattered light intensities resulting in the shadow region at an observation plane behind monochromatically illuminated circular cylinders are modeled by sinusoidal sequences having a squared dependence on spatial position in the observation plane. Whereas two sinusoidal components appear to be sufficient for modeling the light distribution behind intransparent cylinders, at least three sinusoidal components are necessary for transparent cylinders. Based on this model, a novel evaluation algorithm for a very fast retrieval of the diameter of thin cylindrical products like metallic wires and transparent fibers is presented. This algorithm was tested in a cylinder diameter range typical for these products (d ≈ 70 … 150 μm; n ≈ 1.5). Numerical examples are given to illustrate its application by using both synthetic and experimental scattering data. Diameter accuracies below 0.05 μm could be achieved for intransparent cylinders in the tested diameter range. However, scattering effects due to morphological-dependent resonances (MDRs) are problematical in the diameter analysis of transparent products. In order to incorporate these effects into the model, further investigations are needed.

  17. [Accuracy of Modulation Transfer Function for Target Size and Field of View in a Circular Edge Strategy Using the CT Image Measurement Program].

    PubMed

    Fukunaga, Masaaki; Onishi, Hideo; Matsutomo, Norikazu; Yamamoto, Hiroyuki

    2016-06-01

    The purpose of this study was to evaluate the effects of target diameter and display-field of view (D-FOV) in modulation transfer function (MTF) by circular edge strategy using the computed tomography (CT) image measurement program "CTmeasure". We calculated the MTF (MTF(edge)) using the circular edge strategy applied to cylindrical phantom (200 mmφ) that inserted with cylinders have 10, 20, 30, and 40 mm diameters. The phantom images were reconstructed using filtered back projection method varied with D-FOV (240, 320, 400, and 500 mm). The study compared both MTF(edge) and MTF(wire) at MTF50% and MTF(10%) for target diameter and D-FOV, respectively. The MTF(edge) by the different of target diameter indicated in rough compatibility. However, MTF(edge) of D-FOV diameters (320, 400, and 500 mm) decreased in the high frequency range. The circular edge strategy for MTF depended on the D-FOV, however, it was little dependent on target diameter using the CT image measurement program "CTmeasure".

  18. Characterization of Mechanical Properties of Nuclear Graphite Using Subsize Specimens and Reusing Tested Specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji Hyun, Yoon; Byun, Thak Sang; Strizak, Joe P

    2011-01-01

    The mechanical properties of NBG-18 nuclear grade graphite have been characterized using small specimen test techniques and statistical treatment on the test results. New fracture strength and toughness test techniques were developed to use subsize cylindrical specimens with glued heads and to reuse their broken halves. Three sets of subsize cylindrical specimens with the different diameters of 4 mm, 8 mm, and 12 mm were tested to obtain tensile fracture strength. The longer piece of the broken halves was cracked from side surfaces and tested under three-point bend loading to obtain fracture toughness. Both the strength and fracture toughness datamore » were analyzed using Weibull distribution models focusing on size effect. The mean fracture strength decreased from 22.9 MPa to 21.5 MPa as the diameter increased from 4 mm to 12 mm, and the mean strength of 15.9 mm diameter standard specimen, 20.9 MPa, was on the extended trend line. These fracture strength data indicate that in the given diameter range the size effect is not significant and much smaller than that predicted by the Weibull statistics-based model. Further, no noticeable size effect existed in the fracture toughness data, whose mean values were in a narrow range of 1.21 1.26 MPa. The Weibull moduli measured for fracture strength and fracture toughness datasets were around 10. It is therefore believed that the small or negligible size effect enables to use the subsize specimens and that the new fracture toughness test method to reuse the broken specimens to help minimize irradiation space and radioactive waste.« less

  19. Implosion dynamics of a megampere wire-array Z-pinch with an inner low-density foam shell at the Angara-5-1 facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aleksandrov, V. V.; Bolkhovitinov, E. A.; Volkov, G. S., E-mail: volkov@triniti.ru

    The implosion dynamics of a pinch with a highly inhomogeneous initial axial distribution of the load mass was studied experimentally. A cascade array consisting of a double nested tungsten wire array and a coaxial inner cylindrical shell located symmetrically with respect to the high-voltage electrodes was used as a load of the Angara-5-1 high-current generator. The cylindrical foam shell was half as long as the cathode− anode gap, and its diameter was equal to the diameter of the inner wire array. It is shown experimentally that two stages are typical of the implosion dynamics of such a load: the formationmore » of two separate pinches formed as a result of implosion of the wire array near the cathode and anode and the subsequent implosion of the central part of the load containing the cylindrical foam shell. The conditions are determined at which the implosion of the central part of the pinch with the foam cylinder is preceded by intense irradiation of the foam with the soft X-ray (SXR) emission generated by the near-electrode pinches and converting it into the plasma state. Using such a load, which models the main elements of the scheme of a dynamic hohlraum for inertial confinement fusion, it is possible to increase the efficiency of interaction between the outer accelerated plasma sheath and the inner foam shell by preionizing the foam with the SXR emission of the near-electrode pinches.« less

  20. Robot Hand Grips Cylinders Securely

    NASA Technical Reports Server (NTRS)

    Parma, George F.

    1989-01-01

    Jaws and linkage accommodate various sizes. Robot hand includes two pairs of parallel jaws that grasp rods, pipes, tubes, struts, and other long, heavy cylindrical objects. Hand features compact rotary drive and butterfly configuration simplifying approach and gripping maneuvers of robot. Parallelogram linkages maintain alignment of each jaw with other jaws. One bar of each linkage connected to one of two concentric, counterrotating shafts; rotation of shafts moves jaws in each pair toward or away from each other to grasp or release workpiece. Each jaw includes rigid gripping pad lined with rubber to give firm grip and to prevent damage to workpiece. Inner cylindrical surface (corner) of each jaw tapers off to flat sides. Enables jaw to grasp workpieces with diameters larger than or equal to twice the corner radius.

  1. Performance and safety of holmium: YAG laser optical fibers.

    PubMed

    Knudsen, Bodo E; Glickman, Randolph D; Stallman, Kenneth J; Maswadi, Saher; Chew, Ben H; Beiko, Darren T; Denstedt, John D; Teichman, Joel M H

    2005-11-01

    Lower-pole ureteronephroscopy requires transmission of holmium:YAG energy along a deflected fiber. Current ureteroscopes are capable of high degrees of deflection, which may stress laser fibers beyond safe limits during lower-pole use. We hypothesized that optical fiber and safety measures differ among manufacturers. Small (200-273-microm) and medium-diameter (300-400-microm) Ho:YAG fibers were tested in a straight and 180 degrees bent configuration. Energy transmission was measured by an energy detector. Fiber durability was assessed by firing the laser in sequentially tighter bending diameters. The fibers were bent to 180 degrees with a diameter of 6 cm and run at 200- to 4000-mJ pulse energy to determine the minimum energy required to fracture the fiber. The bending diameter was decreased by 1-cm increments and testing repeated until a bending diameter of 1 cm was reached. The maximum deflection of the ACMI DUR-8E ureteroscope with each fiber in the working channel was recorded. The flow rate through the working channel of the DUR-8E was measured for each fiber. The mean energy transmission differed among fibers (P < 0.001). The Lumenis SL 200 and the InnovaQuartz 400 were the best small and medium-diameter fibers, respectively, in resisting thermal breakdown (P < 0.01). The Dornier Lightguide Super 200 fractured repeatedly at a bend diameter of 2 cm and with the lowest energy (200 mJ). The other small fibers fractured only at a bend diameter of 1 cm. The Sharplan 200 and InnovaQuartz Sureflex 273T were the most flexible fibers, the Lumenis SL 365 the least. The flow rate was inversely proportional to four times the power of the diameter of the fiber. Optical performance and safety differ among fibers. Fibers transmit various amounts of energy to their cladding when bent. During lower-pole nephroscopy with the fiber deflected, there is a risk of fiber fracture from thermal breakdown and laser-energy transmission to the endoscope. Some available laser fibers carry a risk of ureteroscope damage.

  2. Discrimination between neoplastic and non-neoplastic lesions in cirrhotic liver using contrast-enhanced ultrasound

    PubMed Central

    Xu, H-X; Lu, M-D; Liu, L-N; Zhang, Y-F; Guo, L-H; Xu, J-M; Liu, C

    2012-01-01

    Objectives To assess the value of contrast-enhanced ultrasound (CEUS) in differentiating hepatocellular carcinoma (HCC) from non-neoplastic lesion in cirrhotic liver in comparison with baseline ultrasound. Methods A total of 147 nodules (diameter ≤5.0 cm) in 133 cirrhotic patients (mean age±standard deviation: 52±13 years, range 20–82 years; gender: 111 males and 22 females) were examined with CEUS. There were 116 HCCs, 26 macroregenerative nodules and 5 high-grade dysplastic nodules. CEUS was performed with a real-time contrast-specific mode and a sulphur hexafluoride-filled microbubble contrast agent. Results Hypervascularity was observed in 94.8% (110/116) HCCs, 3.8% (1/26) macroregenerative nodules and 60.0% (3/5) high-grade dysplastic nodules during arterial phase on CEUS. Detection rates of typical vascular pattern (i.e. hypervascularity during arterial phase and subsequent washout) in HCCs with a diameter of ≤2.0 cm, 2.1–3.0 cm and 3.1–5.0 cm were 69.2% (27/39), 97.1% (33/34) and 100.0% (43/43), respectively. CEUS significantly improved the sensitivity [88.8% (103/116) vs 37.1% (43/116), p<0.001], negative predictive value [70.5% (31/44) vs 31.5% (29/92), p<0.001], and accuracy [91.2% (134/147) vs 49.0% (72/147), p<0.001] in differentiating HCCs from non-neoplastic lesions when compared with baseline ultrasound. However, the sensitivity and accuracy of CEUS for HCCs ≤2.0 cm in diameter were significantly lower than those for HCCs of 2.1–3.0 cm and 3.1–5.0 cm in diameter. Conclusions CEUS improves diagnostic performance in differentiating HCCs from non-neoplastic nodules in cirrhotic patients compared with baseline ultrasound. Diagnosis of HCCs ≤2.0 cm diameter by CEUS is still a clinical concern, and thus needs further investigation. PMID:22553290

  3. A 20000-hour endurance test of a structurally and thermally integrated 5-cm diameter ion thruster main cathode

    NASA Technical Reports Server (NTRS)

    Wintucky, E. G.

    1975-01-01

    A 5-cm diameter mercury ion thruster main cathode has completed over 20,000 hours of operation in an ongoing lifetime endurance test. The cathode operating parameters remained at acceptable performance levels throughout the test, the first 9175 hours of which were part of a thruster endurance test. After 20,000 hours, the cathode discharge was easily restarted, the tip orifice indicated negligible erosion and the tip heater showed no degradation. The cathode-isolator- vaporizer assembly, a major thruster subsystem, has thus successfully demonstrated an operational lifetime capability of 20,000 hours, which is the lifetime goal of the 8-cm diameter auxiliary propulsion ion thruster.

  4. Ion optics for high power 50-cm-diam ion thrusters

    NASA Technical Reports Server (NTRS)

    Rawlin, Vincent K.; Millis, Marc G.

    1989-01-01

    The process used at the NASA-Lewis to fabricate 30 and 50-cm-diameter ion optics is described. The ion extraction capabilities of the 30 and 50-cm diameter ion optics were evaluated on divergent field and ring-cusp discharge chambers and compared. Perveance was found to be sensitive to the effects of the type and power of the discharge chamber and to the accelerator electrode hole diameter. Levels of up to 0.64 N and 20 kW for thrust and input power, respectively, were demonstrated with the divergent-field discharge chamber. Thruster efficiencies and specific impulse values up to 79 percent and 5000 sec., respectively, were achieved with the ring-cusp discharge chamber.

  5. Temperature compensated sleeve type mirror mount

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The primary mirror of a large (26-inch diameter aperture) solar telescope was made of glass ceramic and designed with an integral hub on the back of the center of the mirror. This permits heat from the mirror to radiate off its back to a nearby cold plate. To permit mounting without high stresses, the hub was ground down to a smooth cylindrical surface 3.5 inch in diameter. The ground surface was then acid-etched to remove 0.007 inch (on the diameter) by immersion for five minutes in a mixture of four parts 92% sulfuric acid and three parts 50% hydrofluoric acid. The acid etching removes microcracks from the ground Cer-Vit surface. An Invar sleeve was fabricated to fit over the hub with about 0.010 inch radial (0.020 inch diametral) clearance.

  6. Transsacral Osseous Corridor Anatomy Is More Amenable To Screw Insertion In Males: A Biomorphometric Analysis of 280 Pelves.

    PubMed

    Gras, Florian; Gottschling, Heiko; Schröder, Manuel; Marintschev, Ivan; Hofmann, Gunther O; Burgkart, Rainer

    2016-10-01

    Percutaneous iliosacral screw placement is the standard procedure for fixation of posterior pelvic ring lesions, although a transsacral screw path is being used more frequently in recent years owing to increased fracture-fixation strength and better ability to fix central and bilateral sacral fractures. However, biomorphometric data for the osseous corridors are limited. Because placement of these screws in a safe and effective manner is crucial to using transsacral screws, we sought to address precise sacral anatomy in more detail to look for anatomic variation in the general population. We asked: (1) What proportion of healthy pelvis specimens have no transsacral corridor at the level of the S1 vertebra owing to sacral dysmorphism? (2) If there is no safe diameter for screw placement in the transsacral S1 corridor, is an increased and thus safe diameter of the transsacral S2 corridor expected? (3) Are there sex-specific differences in sacral anatomy and are these correlated with known anthropometric parameters? CT scans of pelves of 280 healthy patients acquired exclusively for medical indications such as polytrauma (20%), CT angiography (70%), and other reasons (10%), were segmented manually. Using an advanced CT-based image analysis system, the mean shape of all segmented pelves was generated and functioned as a template. On this template, the cylindric transsacral osseous corridor at the level of the S1 and S2 vertebrae was determined manually. Each pelvis then was registered to the template using a free-form registration algorithm to measure the maximum screw corridor diameters on each specimen semiautomatically. Thirty of 280 pelves (11%) had no transsacral S1 corridor owing to sacral dysmorphism. The average of maximum cylindrical diameters of the S1 corridor for the remaining 250 pelves was 12.8 mm (95% CI, 12.1-13.5 mm). A transverse corridor for S2 was found in 279 of 280 pelves, with an average of maximum cylindrical diameter of 11.6 mm (95% CI, 11.3-11.9 mm). Decreasing transsacral S1 corridor diameters are correlated with increasing transsacral S2 corridor diameters (R value for females, -0.260, p < 0.01; for males, -0.311, p < 0.001). Female specimens were more likely to have sacral dysmorphism (defined as a pelvis without a transsacral osseous corridor at the level of the S1 vertebra) than were male specimens (females, 16%; males, 7%; p < 0.003). Furthermore female pelves had smaller-corridor diameters than did male pelves (females versus males for S1: 11.7 mm [95% CI, 10.6-12.8 mm] versus 13.5 mm [95% CI, 12.6-14.4 mm], p < 0.01; and for S2: 10.6 mm [95% CI, 10.1-11.1 mm] versus 12.2 mm [95% CI, 11.8-12.6 mm ], p < 0.0001). Narrow corridors and highly individual, sex-dependent variance of morphologic features of the sacrum make transsacral implant placement technically demanding. Individual preoperative axial-slice CT scan analyses and orthogonal coronal and sagittal reformations are recommended to determine the prevalence of sufficient-sized osseous corridors on both levels for safe screw placements, especially in female patients, owing to their smaller corridor diameters and higher rate of sacral dysmorphism.

  7. Air temperature sensors: dependence of radiative errors on sensor diameter in precision metrology and meteorology

    NASA Astrophysics Data System (ADS)

    de Podesta, Michael; Bell, Stephanie; Underwood, Robin

    2018-04-01

    In both meteorological and metrological applications, it is well known that air temperature sensors are susceptible to radiative errors. However, it is not widely known that the radiative error measured by an air temperature sensor in flowing air depends upon the sensor diameter, with smaller sensors reporting values closer to true air temperature. This is not a transient effect related to sensor heat capacity, but a fluid-dynamical effect arising from heat and mass flow in cylindrical geometries. This result has been known historically and is in meteorology text books. However, its significance does not appear to be widely appreciated and, as a consequence, air temperature can be—and probably is being—widely mis-estimated. In this paper, we first review prior descriptions of the ‘sensor size’ effect from the metrological and meteorological literature. We develop a heat transfer model to describe the process for cylindrical sensors, and evaluate the predicted temperature error for a range of sensor sizes and air speeds. We compare these predictions with published predictions and measurements. We report measurements demonstrating this effect in two laboratories at NPL in which the air flow and temperature are exceptionally closely controlled. The results are consistent with the heat-transfer model, and show that the air temperature error is proportional to the square root of the sensor diameter and that, even under good laboratory conditions, it can exceed 0.1 °C for a 6 mm diameter sensor. We then consider the implications of this result. In metrological applications, errors of the order of 0.1 °C are significant, representing limiting uncertainties in dimensional and mass measurements. In meteorological applications, radiative errors can easily be much larger. But in both cases, an understanding of the diameter dependence allows assessment and correction of the radiative error using a multi-sensor technique.

  8. Investigation of electrodes under flow of a submicrosecond current pulse with linear density up to 3 MA/cm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Branitskii, A. V.; Grabovskii, E. V.; Dzhangobegov, V. V.

    The states of current-carrying elements at the transmission of megaampere current into load are studied. It is determined that the expansion velocity of plasma generated at the outer surface of cylindrical tubes produced of stainless steel, at flowing through them of submicrosecond current pulses with linear density of 3 MA/cm is 5.5 km/s. The evolution of various modes of instability is analyzed.

  9. Effect of CO2 laser on root caries inhibition around composite restorations: an in vitro study.

    PubMed

    de Melo, Jociana Bandeira; Hanashiro, Fernando Seishim; Steagall, Washington; Turbino, Miriam Lacalle; Nobre-dos-Santos, Marinês; Youssef, Michel Nicolau; de Souza-Zaroni, Wanessa Christine

    2014-03-01

    The aim of the present study was to investigate the in vitro effect of CO2 laser on the inhibition of root surface demineralization around composite resin restorations. For this purpose, 30 blocks obtained from human molar roots were divided into three groups: group 1 (negative control), cavity prepared with cylindrical diamond bur + acid etching + adhesive + composite resin restoration; group 2, cavity prepared with cylindrical diamond bur + CO2 laser (5.0 J/cm(2)) + acid etching + adhesive + composite resin; and group 3, cavity prepared with cylindrical diamond bur + CO2 laser (6.0 J/cm(2)) + acid etching + adhesive + composite resin. After this procedure, the blocks were submitted to thermal and pH cycling. Root surface demineralization around the restorations was measured by microhardness analysis. The hardness results of the longitudinally sectioned root surface were converted into percentage of mineral volume, which was used to calculate the mineral loss delta Z (ΔZ). The percentage of mineral volume, ΔZ, and the percentage of demineralization inhibition of the groups were statistically analyzed by using analysis of variance and Tukey-Kramer test. The percentage of mineral volume was higher in the irradiated groups up to 80 μm deep. The ΔZ was significantly lower in the irradiated groups than in the control group. The percentage of reduction in demineralization ranged from 19.73 to 29.21 in position 1 (50 μm), and from 24.76 to 26.73 in position 2 (100 μm), when using 6 and 5 J/cm(2), respectively. The CO2 laser was effective in inhibiting root demineralization around composite resin restorations.

  10. Determination of optical properties in heterogeneous turbid media using a cylindrical diffusing fiber

    NASA Astrophysics Data System (ADS)

    Dimofte, Andreea; Finlay, Jarod C.; Liang, Xing; Zhu, Timothy C.

    2012-10-01

    For interstitial photodynamic therapy (PDT), cylindrical diffusing fibers (CDFs) are often used to deliver light. This study examines the feasibility and accuracy of using CDFs to characterize the absorption (μa) and reduced scattering (μ‧s) coefficients of heterogeneous turbid media. Measurements were performed in tissue-simulating phantoms with μa between 0.1 and 1 cm-1 and μ‧s between 3 and 10 cm-1 with CDFs 2 to 4 cm in length. Optical properties were determined by fitting the measured light fluence rate profiles at a fixed distance from the CDF axis using a heterogeneous kernel model in which the cylindrical diffusing fiber is treated as a series of point sources. The resulting optical properties were compared with independent measurement using a point source method. In a homogenous medium, we are able to determine the absorption coefficient μa using a value of μ‧s determined a priori (uniform fit) or μ‧s obtained by fitting (variable fit) with standard (maximum) deviations of 6% (18%) and 18% (44%), respectively. However, the CDF method is found to be insensitive to variations in μ‧s, thus requiring a complementary method such as using a point source for determination of μ‧s. The error for determining μa decreases in very heterogeneous turbid media because of the local absorption extremes. The data acquisition time for obtaining the one-dimensional optical properties distribution is less than 8 s. This method can result in dramatically improved accuracy of light fluence rate calculation for CDFs for prostate PDT in vivo when the same model and geometry is used for forward calculations using the extrapolated tissue optical properties.

  11. Thirty-Eight Years of Autogenic, Woody Understory Dynamics in a Mature, Temperate Pine-Oak Forest

    Treesearch

    Michael D. Cain; Michael G. Shelton

    1997-01-01

    In 1935, 32 ha of a pine-hardwood forest were set aside from future timber management in southern Arkansas, U.S.A. Old-growth timber had been cut to a 36-cm stump diameter before 1915. Between 1952 and 1993, four inventories were made of the overstory and midstory components (number of live trees 29 cm in diameter breast height (DBH) taken at 1.37 m, by 2.54-cm DBH...

  12. Volumetric Growth of the Liver in the Human Fetus: An Anatomical, Hydrostatic, and Statistical Study.

    PubMed

    Szpinda, Michał; Paruszewska-Achtel, Monika; Woźniak, Alina; Mila-Kierzenkowska, Celestyna; Elminowska-Wenda, Gabriela; Dombek, Małgorzata; Szpinda, Anna; Badura, Mateusz

    2015-01-01

    Using anatomical, hydrostatic, and statistical methods, liver volumes were assessed in 69 human fetuses of both sexes aged 18-30 weeks. No sex differences were found. The median of liver volume achieved by hydrostatic measurements increased from 6.57 cm(3) at 18-21 weeks through 14.36 cm(3) at 22-25 weeks to 20.77 cm(3) at 26-30 weeks, according to the following regression: y = -26.95 + 1.74 × age ± Z × (-3.15 + 0.27 × age). The median of liver volume calculated indirectly according to the formula liver volume = 0.55 × liver length × liver transverse diameter × liver sagittal diameter increased from 12.41 cm(3) at 18-21 weeks through 28.21 cm(3) at 22-25 weeks to 49.69 cm(3) at 26-30 weeks. There was a strong relationship (r = 0.91, p < 0.001) between the liver volumes achieved by hydrostatic (x) and indirect (y) methods, expressed by y = -0.05 + 2.16x ± 7.26. The liver volume should be calculated as follows liver volume = 0.26 × liver length × liver transverse diameter × liver sagittal diameter. The age-specific liver volumes are of great relevance in the evaluation of the normal hepatic growth and the early diagnosis of fetal micro- and macrosomias.

  13. Use of disposable graduated biopsy forceps improves accuracy of polyp size measurements during endoscopy.

    PubMed

    Jin, Hei-Ying; Leng, Qiang

    2015-01-14

    To determine the accuracy of endoscopic polyp size measurements using disposable graduated biopsy forceps (DGBF). Gradations accurate to 1 mm were assessed with the wire of disposable graduated biopsy forceps. When a polyp was noted, endoscopists determined the width of the polyp; then, the graduated biopsy forceps was inserted and the largest diameter of the tumor was measured. After excision, during surgery or endoscopy, the polyp was measured using the vernier caliper. One hundred and thirty-three colorectal polyps from 119 patients were studied. The mean diameter, by post-polypectomy measurement, was 0.92 ± 0.69 cm; 83 were < 1 cm, 36 were between 1 and 2 cm, and 14 were > 2 cm. The mean diameter, by visual estimation, was 1.15 ± 0.88 cm; compared to the actual size measured using vernier calipers, the difference was statistically significant. The mean diameter measured using the DGBF was 0.93 ± 0.68 cm; compared to the actual size measured using vernier calipers, this difference was not statistically significant. The ratio between the mean size estimated by visual estimation and the actual size was significantly different from that between the mean size estimated using the DGBF and the actual size (1.26 ± 0.30 vs 1.02 ± 0.11). The accuracy of polyp size estimation was low by visual assessment; however, it improved when the DGBF was used.

  14. Three-step cylindrical seal for high-performance turbomachines

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.

    1987-01-01

    A three-step cylindrical seal configuration representing the seal for a high performance turbopump (e.g., the space shuttle main engine fuel pump) was tested under static (nonrotating) conditions. The test data included critical mass flux and pressure profiles over a wide range of inlet temperatures and pressures for fluid nitrogen and fluid hydrogen with the seal in concentric and fully eccentric positions. The critical mass flux (leakage rate) was 70% that of an equivalent straight cylindrical seal with a correspondingly higher pressure drop based on the same flow areas of 0.3569 sq cm but 85% that of the straight seal based on the third-step flow area of 0.3044 sq cm. The mass flow rates for the three step cylindrical seal in the fully eccentric and concentric positions were essentially the same, and the trends in flow coefficient followed those of a simple axisymmetric inlet configuration. However, for inlet stagnation temperatures less than the thermodynamic critical temperature the pressure profiles exhibited a flat region throughout the third step of the seal, with the pressure magnitude dependent on the inlet stagnation temperature. Such profiles represent an extreme positive direct stiffness. These conditions engendered a crossover in the pressure profile upstream of the postulated choke that resulted in a local negative stiffness. Flat and crossover profiles resulting from choking within the seal are practically unknown to the seal designer. However, they are of critical importance to turbomachine stability and must be integrated into any dynamic analysis of a seal of this configuration. In addition, choking is highly dependent on geometry, inlet-to-backpressure ratio, and inlet temperature and can occur within the seal even though the backpressure is above the critical pressure.

  15. Performance of a cylindrical phase-change thermal energy storage unit

    NASA Astrophysics Data System (ADS)

    Jacobson, D. L.; Ponnappan, R.

    1983-05-01

    The high-temperature performance of a eutectic salt Phase Change Material (PCM) in a cylindrical Thermal Energy Storage Container (TESC) sample is evaluated by means of an experimental apparatus with a water-circulated calorimeter. The phase change characteristics of the salt during melting and solidification were observed by monitoring the external axial temperature profile of the container, and the analysis of the phase change heat transfer in the cylindrical geometry was based on the modified heat balance integral method of Tien (1980), which provides the solidification rate and time. Melting point (983 K), freezing point (944 K), latent heat of fusion (782.26 J/gm) and thermal diffusivity (0.00799 sq cm/sec) results are in agreement with those found in the literature. The experimental and analytical results of the nondimensionalized heat transfer resistance as a function of the solidified or melted weight fraction are compared.

  16. Infertility associated with persistent hymen in an alpaca and a llama

    PubMed Central

    Tan, Rachel H.H.; Dascanio, John J.

    2008-01-01

    Perforation and dilation of the persistent hymen in an alpaca and a llama, detected by vaginal examination and endoscopy, was achieved by use of a sigmoidoscope and incremental dilation using cylindrical instruments to a maximum diameter of 38 mm. Outcome and subsequent fertility are dependent on length of time the obstruction has been present and secondary uterine disease. PMID:19183735

  17. Polymer dynamics under cylindrical confinement featuring a locally repulsive surface: A quasielastic neutron scattering study.

    PubMed

    Krutyeva, M; Pasini, S; Monkenbusch, M; Allgaier, J; Maiz, J; Mijangos, C; Hartmann-Azanza, B; Steinhart, M; Jalarvo, N; Richter, D

    2017-05-28

    We investigated the effect of intermediate cylindrical confinement with locally repulsive walls on the segmental and entanglement dynamics of a polymer melt by quasielastic neutron scattering. As a reference, the corresponding polymer melt was measured under identical conditions. The locally repulsive confinement was realized by hydrophilic anodic alumina nanopores with a diameter of 20 nm. The end-to-end distance of the hydrophobic infiltrated polyethylene-alt-propylene was close to this diameter. In the case of hard wall repulsion with negligible local attraction, several simulations predicted an acceleration of segmental dynamics close to the wall. Other than in attractive or neutral systems, where the segmental dynamics is slowed down, we found that the segmental dynamics in the nanopores is identical to the local mobility in the bulk. Even under very careful scrutiny, we could not find any acceleration of the surface-near segmental motion. On the larger time scale, the neutron spin-echo experiment showed that the Rouse relaxation was not altered by confinement effects. Also the entanglement dynamics was not affected. Thus at moderate confinement conditions, facilitated by locally repulsive walls, the dynamics remains as in the bulk melt, a result that is not so clear from simulations.

  18. Mamdani-Fuzzy Modeling Approach for Quality Prediction of Non-Linear Laser Lathing Process

    NASA Astrophysics Data System (ADS)

    Sivaraos; Khalim, A. Z.; Salleh, M. S.; Sivakumar, D.; Kadirgama, K.

    2018-03-01

    Lathing is a process to fashioning stock materials into desired cylindrical shapes which usually performed by traditional lathe machine. But, the recent rapid advancements in engineering materials and precision demand gives a great challenge to the traditional method. The main drawback of conventional lathe is its mechanical contact which brings to the undesirable tool wear, heat affected zone, finishing, and dimensional accuracy especially taper quality in machining of stock with high length to diameter ratio. Therefore, a novel approach has been devised to investigate in transforming a 2D flatbed CO2 laser cutting machine into 3D laser lathing capability as an alternative solution. Three significant design parameters were selected for this experiment, namely cutting speed, spinning speed, and depth of cut. Total of 24 experiments were performed with eight (8) sequential runs where they were then replicated three (3) times. The experimental results were then used to establish Mamdani - Fuzzy predictive model where it yields the accuracy of more than 95%. Thus, the proposed Mamdani - Fuzzy modelling approach is found very much suitable and practical for quality prediction of non-linear laser lathing process for cylindrical stocks of 10mm diameter.

  19. Conformal SiO2 coating of sub-100 nm diameter channels of polycarbonate etched ion-track channels by atomic layer deposition

    PubMed Central

    Sobel, Nicolas; Lukas, Manuela; Spende, Anne; Stühn, Bernd; Trautmann, Christina

    2015-01-01

    Summary Polycarbonate etched ion-track membranes with about 30 µm long and 50 nm wide cylindrical channels were conformally coated with SiO2 by atomic layer deposition (ALD). The process was performed at 50 °C to avoid thermal damage to the polymer membrane. Analysis of the coated membranes by small angle X-ray scattering (SAXS) reveals a homogeneous, conformal layer of SiO2 in the channels at a deposition rate of 1.7–1.8 Å per ALD cycle. Characterization by infrared and X-ray photoelectron spectroscopy (XPS) confirms the stoichiometric composition of the SiO2 films. Detailed XPS analysis reveals that the mechanism of SiO2 formation is based on subsurface crystal growth. By dissolving the polymer, the silica nanotubes are released from the ion-track membrane. The thickness of the tube wall is well controlled by the ALD process. Because the track-etched channels exhibited diameters in the range of nanometres and lengths in the range of micrometres, cylindrical tubes with an aspect ratio as large as 3000 have been produced. PMID:25821688

  20. PCA Based Stress Monitoring of Cylindrical Specimens Using PZTs and Guided Waves

    PubMed Central

    Mujica, Luis; Ruiz, Magda; Camacho, Johanatan

    2017-01-01

    Since mechanical stress in structures affects issues such as strength, expected operational life and dimensional stability, a continuous stress monitoring scheme is necessary for a complete integrity assessment. Consequently, this paper proposes a stress monitoring scheme for cylindrical specimens, which are widely used in structures such as pipelines, wind turbines or bridges. The approach consists of tracking guided wave variations due to load changes, by comparing wave statistical patterns via Principal Component Analysis (PCA). Each load scenario is projected to the PCA space by means of a baseline model and represented using the Q-statistical indices. Experimental validation of the proposed methodology is conducted on two specimens: (i) a 12.7 mm (1/2″) diameter, 0.4 m length, AISI 1020 steel rod, and (ii) a 25.4 mm (1″) diameter, 6m length, schedule 40, A-106, hollow cylinder. Specimen 1 was subjected to axial loads, meanwhile specimen 2 to flexion. In both cases, simultaneous longitudinal and flexural guided waves were generated via piezoelectric devices (PZTs) in a pitch-catch configuration. Experimental results show the feasibility of the approach and its potential use as in-situ continuous stress monitoring application. PMID:29194384

  1. Incidence angle bounds for lip flow separation of three 13.97-centimeter-diameter inlets

    NASA Technical Reports Server (NTRS)

    Luidens, R. W.; Abbott, J. M.

    1976-01-01

    Low speed wind tunnel tests were conducted to establish a procedure for determining inlet-lip flow separation and to make preliminary examination of the incidence angle bounds for lip flow separation on inlets intended for the nacelles of STOL (short takeoff and landing) aircraft. Three inlets were tested. Two of the inlets had short centerbodies with lower lip area contraction ratios of 1.30 and 1.44. The third inlet had a cylindrical centerbody extended forward into the inlet throat with a lower lip area contraction ratio of 1.44. The inlets were sized to fit a 13.97 centimeter-diameter fan. For inlet throat Mach numbers less than about 0.43, the lip flow separation angle was increased by either increasing the ratio of throat velocity to freestream velocity (Vt/Vo) or by increasing the lower lip area contraction ratio. For throat Mach numbers greater than a certain value (ranging from 0.43 to 0.52), increasing throat Mach number in some cases resulted in a decrease in the lip flow separation angle. Extending a cylindrical centerbody into the inlet throat increased the flow separation angle for nearly all values of Vt/Vo.

  2. Polymer dynamics under cylindrical confinement featuring a locally repulsive surface: A quasielastic neutron scattering study

    NASA Astrophysics Data System (ADS)

    Krutyeva, M.; Pasini, S.; Monkenbusch, M.; Allgaier, J.; Maiz, J.; Mijangos, C.; Hartmann-Azanza, B.; Steinhart, M.; Jalarvo, N.; Richter, D.

    2017-05-01

    We investigated the effect of intermediate cylindrical confinement with locally repulsive walls on the segmental and entanglement dynamics of a polymer melt by quasielastic neutron scattering. As a reference, the corresponding polymer melt was measured under identical conditions. The locally repulsive confinement was realized by hydrophilic anodic alumina nanopores with a diameter of 20 nm. The end-to-end distance of the hydrophobic infiltrated polyethylene-alt-propylene was close to this diameter. In the case of hard wall repulsion with negligible local attraction, several simulations predicted an acceleration of segmental dynamics close to the wall. Other than in attractive or neutral systems, where the segmental dynamics is slowed down, we found that the segmental dynamics in the nanopores is identical to the local mobility in the bulk. Even under very careful scrutiny, we could not find any acceleration of the surface-near segmental motion. On the larger time scale, the neutron spin-echo experiment showed that the Rouse relaxation was not altered by confinement effects. Also the entanglement dynamics was not affected. Thus at moderate confinement conditions, facilitated by locally repulsive walls, the dynamics remains as in the bulk melt, a result that is not so clear from simulations.

  3. Development of Minimally Invasive Medical Tools Using Laser Processing on Cylindrical Substrates

    NASA Astrophysics Data System (ADS)

    Haga, Yoichi; Muyari, Yuta; Goto, Shoji; Matsunaga, Tadao; Esashi, Masayoshi

    This paper reports micro-fabrication techniques using laser processing on cylindrical substrates for the realization of high-performance multifunctional minimally invasive medical tools with small sizes. A spring-shaped shape memory alloy (SMA) micro-coil with a square cross section has been fabricated by spiral cutting of a Ti-Ni SMA tube with a femtosecond laser. Small diameter active bending catheter which is actuated by hydraulic suction mechanism for intravascular minimally invasive diagnostics and therapy has also been developed. The catheter is made of a Ti-Ni super elastic alloy (SEA) tube which is processed by laser micromachining and a silicone rubber tube which covers the outside of the SEA tube. The active catheter is effective for insertion in branch of blood vessel which diverse in acute angle which is difficult to proceed. Multilayer metallization and patterning have been performed on glass tubes with 2 and 3 mm external diameters using maskless lithography techniques using a laser exposure system. Using laser soldering technique, a integrated circuit parts have been mounted on a multilayer circuit patterned on a glass tube. These fabrication techniques will effective for realization of high-performance multifunctional catheters, endoscopic tools, and implanted small capsules.

  4. Construction of 3.6m ARIES telescope enclosure with eccentric pier at Devasthal, Nainital

    NASA Astrophysics Data System (ADS)

    Bangia, Tarun

    Space optimized enclosure with eccentric pier for 3.6m ARIES telescope presents construction challenges at the unique observing site of Devasthal, Nainital, India. Enclosure comprises of about 16.5m diameter and 14m high insulated steel framed cylindrical dome rotating on a 14m high stationery dome supporting structure and a 24m × 12m extension structure building for accommodating aluminizing plant and ventilation system etc. Great deal of manual and mechanical excavation was carried out at the rocky site using rock breaking and JCB machines. Foundation bolts for columns of dome supporting structure and extension structure building were grouted after alignment with total station. A 7m diameter hollow cylindrical pier isolated from other structures and 1.85m eccentric with dome center designed due to space limitation at site is being casted for mounting 150 MT mass of the largest 3.6m telescope in the country. A 7m diameter template was fabricated for 3.6m pier top. Most of enclosure components are manufactured and tested in works before assembly/erection at site. Dome drive was tested with dummy loads using VVVF drive with 6 drive and 12 idler wheel assemblies at works to simulate dome weight and smooth operation before erection at site. A 4.2m wide motorized windscreen is being manufactured with a special grade synthetic fabric to withstand wind speed up to 15m/s.

  5. De Vega Annuloplasty for Functional Tricupsid Regurgitation: Concept of Tricuspid Valve Orifice Index to Optimize Tricuspid Valve Annular Reduction

    PubMed Central

    Hwang, Ho Young; Chang, Hyoung Woo; Jeong, Dong Seop

    2013-01-01

    We evaluated long-term results of De Vega annuloplasty measured by cylindrical sizers for functional tricuspid regurgitation (FTR) and analyzed the impact of measured annular size on the late recurrence of tricuspid valve regurgitation. Between 2001 and 2011, 177 patients (57.9±10.5 yr) underwent De Vega annuloplasty for FTR. Three cylindrical sizers (actual diameters of 29.5, 31.5, and 33.5 mm) were used to reproducibly reduce the tricuspid annulus. Long-term outcomes were evaluated and risk factor analyses for the recurrence of FTR ≥3+ were performed. Measured annular diameter indexed by patient's body surface area was included in the analyses as a possible risk factor. Operative mortality occurred in 8 patients (4.5%). Ten-year overall and cardiac death-free survivals were 80.5% and 90.8%, respectively. Five and 10-yr freedom rates from recurrent FTR were 96.5% and 93.1%, respectively. Cox proportional hazard model revealed that higher indexed annular size was the only risk factor for the recurrence of FTR (P=0.006). A minimal P value approach demonstrated that indexed annular diameter of 22.5 mm/m2 was a cut-off value predicting the recurrence of FTR. De Vega annuloplasty for FTR results in low rates of recurrent FTR in the long-term. Tricuspid annulus should be reduced appropriately considering patients' body size to prevent recurrent FTR. PMID:24339705

  6. Time history of diesel particle deposition in cylindrical dielectric barrier discharge reactors

    NASA Astrophysics Data System (ADS)

    Talebizadeh, P.; Rahimzadeh, H.; Ahmadi, G.; Brown, R.; Inthavong, K.

    2016-12-01

    Non-thermal plasma (NTP) treatment reactors have recently been developed for elimination of diesel particulate matter for reducing both the mass and number concentration of particles. The role of the plasma itself is obscured by the phenomenon of particle deposition on the reactor surface. Therefore, in this study, the Lagrangian particle transport model is used to simulate the dispersion and deposition of nano-particles in the range of 5 to 500 nm in a NTP reactor in the absence of an electric field. A conventional cylindrical dielectric barrier discharge reactor is selected for the analysis. Brownian diffusion, gravity and Saffman lift forces were included in the simulations, and the deposition efficiencies of different sized diesel particles were studied. The results show that for the studied particle diameters, the effect of Saffman lift is negligible and gravity only affects the motion of particles with a diameter of 500 nm or larger. Time histories of particle transport and deposition were evaluated for one-time injection and a continuous (multiple-time) injection. The results show that the number of deposited particles for one-time injection is identical to the number of deposited particles for multiple-time injections when adjusted with the shift in time. Furthermore, the maximum number of escaped particles occurs at 0.045 s after the injection for all particle diameters. The presented results show that some particle reduction previously ascribed to plasma treatment has ignored contributions from the surface deposition.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kyakuno, Haruka, E-mail: h-kyakuno@kanagawa-u.ac.jp; Institute of Physics, Faculty of Engineering, Kanagawa University, Yokohama 221-8686; Fukasawa, Mamoru

    Single-wall carbon nanotubes (SWCNTs) are a good model system that provides atomically smooth nanocavities. It has been reported that water-SWCNTs exhibit hydrophobicity depending on the temperature T and the SWCNT diameter D. SWCNTs adsorb water molecules spontaneously in their cylindrical pores around room temperature, whereas they exhibit a hydrophilic-hydrophobic transition or wet-dry transition (WDT) at a critical temperature T{sub wd} ≈ 220-230 K and above a critical diameter D{sub c} ≈ 1.4-1.6 nm. However, details of the WDT phenomenon and its mechanism remain unknown. Here, we report a systematic experimental study involving X-ray diffraction, optical microscopy, and differential scanning calorimetry.more » It is found that water molecules inside thick SWCNTs (D > D{sub c}) evaporate and condense into ice Ih outside the SWCNTs at T{sub wd} upon cooling, and the ice Ih evaporates and condenses inside the SWCNTs upon heating. On the other hand, residual water trapped inside the SWCNTs below T{sub wd} freezes. Molecular dynamics simulations indicate that upon lowering T, the hydrophobicity of thick SWCNTs increases without any structural transition, while the water inside thin SWCNTs (D < D{sub c}) exhibits a structural transition, forming an ordered ice. This ice has a well-developed hydrogen bonding network adapting to the cylindrical pores of the SWCNTs. Thus, the unusual diameter dependence of the WDT is attributed to the adaptability of the structure of water to the pore dimension and shape.« less

  8. Segmented lasing tube for high temperature laser assembly

    DOEpatents

    Sawicki, Richard H.; Alger, Terry W.; Finucane, Raymond G.; Hall, Jerome P.

    1996-01-01

    A high temperature laser assembly capable of withstanding operating temperatures in excess of 1500.degree. C. is described comprising a segmented cylindrical ceramic lasing tube having a plurality of cylindrical ceramic lasing tube segments of the same inner and outer diameters non-rigidly joined together in axial alignment; insulation of uniform thickness surround the walls of the ceramic lasing tube; a ceramic casing, preferably of quartz, surrounding the insulation; and a fluid cooled metal jacket surrounds the ceramic casing. In a preferred embodiment, the inner surface of each of the ceramic lasing tube segments are provided with a pair of oppositely spaced grooves in the wall thereof parallel to the center axis of the segmented cylindrical ceramic lasing tube, and both of the grooves and the center axis of the segmented cylindrical ceramic lasing tube lie in a common plane, with the grooves in each ceramic lasing tube segment in circumferential alignment with the grooves in the adjoining ceramic lasing tube segments; and one or more ceramic plates, all lying in a common plane to one another and with the central axis of the segmented ceramic lasing tube, are received in the grooves to provide additional wall area in the segmented ceramic lasing tube for collision and return to ground state of metastable metal atoms within the segmented ceramic lasing tube.

  9. Particle scavenging in a cylindrical ultrasonic standing wave field using levitated drops

    NASA Astrophysics Data System (ADS)

    Merrell, Tyler; Saylor, J. R.

    2015-11-01

    A cylindrical ultrasonic standing wave field was generated in a tube containing a flow of particles and fog. Both the particles and fog drops were concentrated in the nodes of the standing wave field where they combined and then grew large enough to fall out of the system. In this way particles were scavenged from the system, cleaning the air. While this approach has been attempted using a standing wave field established between disc-shaped transducers, a cylindrical resonator has not been used for this purpose heretofore. The resonator was constructed by bolting three Langevin transducers to an aluminum tube. The benefit of the cylindrical geometry is that the acoustic energy is focused. Furthermore, the residence time of the particle in the field can be increased by increasing the length of the resonator. An additional benefit of this approach is that tubes located downstream of the resonator were acoustically excited, acting as passive resonators that enhanced the scavenging process. The performance of this system on scavenging particles is presented as a function of particle diameter and volumetric flow rate. It is noted that, when operated without particles, the setup can be used to remove drops and shows promise for liquid aerosol retention from systems where these losses can be financially disadvantageous and/or hazardous.

  10. Eight-cm mercury ion thruster system technology

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The technology status of 8 cm diameter electron bombardment ion thrusters is presented. Much of the technology resulting from the 5 cm diameter thruster has been adapted and improved upon to increase the reliability, durability, and efficiency of the 8 cm thruster. Technology discussed includes: dependence of neutralizer tip erosion upon neutralizer flow rate; impregnated and rolled-foil insert cathode performance and life testing; neutralizer position studies; thruster ion beam profile measurements; high voltage pulse ignition; high utilization ion machined accelerator grids; deposition internal and external to the thruster; thruster vectoring systems; thruster cycling life testing and thruster system weights for typical mission applications.

  11. Dosimetric effects of saline- versus water-filled balloon applicators for IORT using the model S700 electronic brachytherapy source.

    PubMed

    Redler, Gage; Templeton, Alistair; Zhen, Heming; Turian, Julius; Bernard, Damian; Chu, James C H; Griem, Katherine L; Liao, Yixiang

    The Xoft Axxent Electronic Brachytherapy System (Xoft, Inc., San Jose, CA) is a viable option for intraoperative radiation therapy (IORT) treatment of early-stage breast cancer. The low-energy (50-kVp) X-ray source simplifies shielding and increases relative biological effectiveness but increases dose distribution sensitivity to medium composition. Treatment planning systems typically assume homogenous water for brachytherapy dose calculations, including precalculated atlas plans for Xoft IORT. However, Xoft recommends saline for balloon applicator filling. This study investigates dosimetric differences due to increased effective atomic number (Z eff ) for saline (Z eff  = 7.56) versus water (Z eff  = 7.42). Balloon applicator diameters range from 3 to 6 cm. Monte Carlo N-Particle software is used to calculate dose at the surface (D s ) of and 1 cm away (D 1cm ) from the water-/saline-filled balloon applicator using a single dwell at the applicator center as a simple estimation of the dosimetry and multiple dwells simulating the clinical dose distributions for the atlas plans. Single-dwell plans show a 4.4-6.1% decrease in D s for the 3- to 6-cm diameter applicators due to the saline. Multidwell plans show similar results: 4.9% and 6.4% D s decrease, for 4-cm and 6-cm diameter applicators, respectively. For the single-dwell plans, D 1cm decreases 3.6-5.2% for the 3- to 6-cm diameter applicators. For the multidwell plans, D 1cm decreases 3.3% and 5.3% for the 4-cm and 6-cm applicators, respectively. The dosimetric effect introduced by saline versus water filling for Xoft balloon applicator-based IORT treatments is ∼5%. Users should be aware of this in the context of both treatment planning and patient outcome studies. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. Indoor Light Performance of Coil Type Cylindrical Dye Sensitized Solar Cells.

    PubMed

    Kapil, Gaurav; Ogomi, Yuhei; Pandey, Shyam S; Ma, Tingli; Hayase, Shuzi

    2016-04-01

    A very good performance under low/diffused light intensities is one of the application areas in which dye-sensitized solar cells (DSSCs) can be utilized effectively compared to their inorganic silicon solar cell counterparts. In this article, we have investigated the 1 SUN and low intensity fluorescent light performance of Titanium (Ti)-coil based cylindrical DSSC (C-DSSC) using ruthenium based N719 dye and organic dyes such as D205 and Y123. Electrochemical impedance spectroscopic results were analyzed for variable solar cell performances. Reflecting mirror with parabolic geometry as concentrator was also utilized to tap diffused light for indoor applications. Fluorescent light at relatively lower illumination intensities (0.2 mW/cm2 to 0.5 mW/cm2) were used for the investigation of TCO-less C-DSSC performance with and without reflector geometry. Furthermore, the DSSC performances were analyzed and compared with the commercially available amorphous silicon based solar cell for indoor applications.

  13. Cup Cylindrical Waveguide Antenna

    NASA Technical Reports Server (NTRS)

    Acosta, Roberto J.; Darby, William G.; Kory, Carol L.; Lambert, Kevin M.; Breen, Daniel P.

    2008-01-01

    The cup cylindrical waveguide antenna (CCWA) is a short backfire microwave antenna capable of simultaneously supporting the transmission or reception of two distinct signals having opposite circular polarizations. Short backfire antennas are widely used in mobile/satellite communications, tracking, telemetry, and wireless local area networks because of their compactness and excellent radiation characteristics. A typical prior short backfire antenna contains a half-wavelength dipole excitation element for linear polarization or crossed half-wavelength dipole elements for circular polarization. In order to achieve simultaneous dual circular polarization, it would be necessary to integrate, into the antenna feed structure, a network of hybrid components, which would introduce significant losses. The CCWA embodies an alternate approach that entails relatively low losses and affords the additional advantage of compactness. The CCWA includes a circular cylindrical cup, a circular disk subreflector, and a circular waveguide that serves as the excitation element. The components that make it possible to obtain simultaneous dual circular polarization are integrated into the circular waveguide. These components are a sixpost polarizer and an orthomode transducer (OMT) with two orthogonal coaxial ports. The overall length of the OMT and polarizer (for the nominal middle design frequency of 2.25 GHz) is about 11 in. (approximately equal to 28 cm), whereas the length of a commercially available OMT and polarizer for the same frequency is about 32 in. (approximately equal to 81 cm).

  14. Nesting biology of Trypoxylon (Trypargilum) lactitarse Saussure (Hymenoptera, Crabronidae) in trap-nests in Southern Brazil.

    PubMed

    Buschini, M L T; Niesing, F; Wolff, L L

    2006-08-01

    This study was carried in the Parque Municipal das Araucárias in the municipality of Guarapuava, state of Paraná, Southern Brazil. Three hundred and sixty five nests of T. lactitarse were obtained using trap-nests of 0.7, 1.0, and 1.3 cm in diameter. All of them had similar architecture, regardless of the diameter of the trap-nest. Completed nests consisted of a linear series of brood cells whose average number per nest was of 3.3, 4.0 and 3.6 for the nests with 0.7 cm, 1.0 cm and 1.3 cm in diameter, respectively. They were constructed more often during the summer. T. lactitarse had two types of life cycles: direct development (without diapause), and delayed development (with diapause during winter). Natural enemies included Chrysididae, Sarcophagidae, Dolichopodidae and Ichneumonidae. Out of 1,353 identified spider prey, 1,313 belonged to the Araneidae family.

  15. Heat dissipation sensors of variable length for the measurement of sap flow in trees with deep sapwood.

    PubMed

    James, Shelley A; Clearwater, Michael J; Meinzer, Frederick C; Goldstein, Guillermo

    2002-03-01

    Robust thermal dissipation sensors of variable length (3 to 30 cm) were developed to overcome limitations to the measurement of radial profiles of sap flow in large-diameter tropical trees with deep sapwood. The effective measuring length of the custom-made sensors was reduced to 1 cm at the tip of a thermally nonconducting shaft, thereby minimizing the influence of nonuniform sap flux density profiles across the sapwood. Sap flow was measured at different depths and circumferential positions in the trunks of four trees at the Parque Natural Metropolitano canopy crane site, Panama City, Republic of Panama. Sap flow was detected to a depth of 24 cm in the trunks of a 1-m-diameter Anacardium excelsum (Bertero & Balb. ex Kunth) Skeels tree and a 0.65-m-diameter Ficus insipida Willd. tree, and to depths of 7 cm in a 0.34-m-diameter Cordia alliodora (Ruiz & Pav.) Cham. trunk, and 17 cm in a 0.47-m-diameter Schefflera morototoni (Aubl.) Maguire, Steyerm. & Frodin trunk. Sap flux density was maximal in the outermost 4 cm of sapwood and declined with increasing sapwood depth. Considerable variation in sap flux density profiles was observed both within and among the trees. In S. morototoni, radial variation in sap flux density was associated with radial variation in wood properties, particularly vessel lumen area and distribution. High variability in radial and circumferential sap flux density resulted in large errors when measurements of sap flow at a single depth, or a single radial profile, were used to estimate whole-plant water use. Diurnal water use ranged from 750 kg H2O day-1 for A. excelsum to 37 kg H2O day-1 for C. alliodora.

  16. Technical note: estimating absorbed doses to the thyroid in CT.

    PubMed

    Huda, Walter; Magill, Dennise; Spampinato, Maria V

    2011-06-01

    To describe a method for estimating absorbed doses to the thyroid in patients undergoing neck CT examinations. Thyroid doses in anthropomorphic phantoms were obtained for all 23 scanner dosimetry data sets in the ImPACT CT patient dosimetry calculator. Values of relative thyroid dose [R(thy)(L)], defined as the thyroid dose for a given scan length (L) divided by the corresponding thyroid dose for a whole body scan, were determined for neck CT scans. Ratios of the maximum thyroid dose to the corresponding CTDI(vol) and [D'(thy)], were obtained for two phantom diameters. The mass-equivalent water cylinder of any patient can be derived from the neck cross-sectional area and the corresponding average Hounsfield Unit, and compared to the 16.5-cm diameter water cylinder that models the ImPACT anthropomorphic phantom neck. Published values of relative doses in water cylinders of varying diameter were used to adjust thyroid doses in the anthropomorphic phantom to those of any sized patient. Relative thyroid doses R(thy)(L) increase to unity with increasing scan length and with very small difference between scanners. A 10-cm scan centered on the thyroid would result in a dose that is, nearly 90% of the thyroid dose from a whole body scan when performed using the constant radiographic techniques. At 120 kV, the average value of D'(thy) for the 16-cm diameter was 1.17 +/- 0.05 and was independent of CT vendor and year of CT scanner, and choice of x-ray tube voltage. The corresponding average value of D'(thy) in the 32-cm diameter phantom was 2.28 +/- 0.22 and showed marked variations depending on vendor, year of introduction into clinical practice as well as x-ray tube voltage. At 120 kV, a neck equivalent to a 10-cm diameter cylinder of water would have thyroid doses 36% higher than those in the ImPACT phantom, whereas a neck equivalent to a 25-cm cylinder diameter would have thyroid doses 35% lower. Patient thyroid doses can be estimated by taking into account the amount of radiation used to perform the CT examination (CTDI(vol)) and accounting for scan length and patient anatomy (i.e., neck diameter) at the thyroid location.

  17. Verde plant bug (Hemiptera: Miridae) feeding injury to cotton bolls characterized by boll age, size, and damage ratings.

    PubMed

    Armstrong, J Scott; Brewer, Michael J; Parker, Roy D; Adamczyk, J J

    2013-02-01

    The verde plant bug, Creontiades signatus (Distant), has been present in south Texas for several years but has more recently been documented as an economic threat to cultivated cotton, (Gossypium hirsutum L. Our studies over 2 yr (2009 and 2010) and two locations (Weslaco and Corpus Christi, TX) investigated feeding-injury of the verde plant bug to a range of cotton boll age classes defined by boll diameter and accumulated degree-days (anthesis to the time of infesting) for first-position cotton bolls infested with the plant bugs. The most detrimental damage to younger cotton holls from verde plant bug feeding was boll abscission. Cotton bolls <04 accumulating daily degree-days (ACDD), or a boll diameter of 1.3 cm were subject to 60-70% higher boll abscission when compared with the noninfested controls. Significantly higher boll abscission occurred from verde plant bug injured bolls compared with the controls up to 162 ACDD or a mean boll diameter 2.0 cm. Cotton seed weights were significantly reduced up to 179 ACDD or a boll diameter of 2.0 cm at Weslaco in 2009, and up to 317 ACDD or boll diameter 2.6 cm for Weslaco in 2010 when compared with the noninfested controls. Lint weight per cotton boll for infested and noninfested bolls was significantly reduced up to 262 ACDD or boll diameter 2.5 for Corpus Christi in 2010 and up to 288 ACCD or boll diameter 2.6 cm for Weslaco, TX, in 2010. Damage ratings (dependant variable) regressed against infested and noninfested seed-cotton weights showed that in every instance, the infested cotton bolls had a strong and significant relationship with damage ratings for all age classes of bolls. Damage ratings for the infested cotton bolls that did not abscise by harvest showed visual signs of verde plant bug feeding injury and the subsequent development ofboll rot; however, these two forms of injury causing lint and seed mass loss are hard to differentiate from open or boll-locked cotton bolls. Based on the results of both lint and seed loss over 2 yr and four studies cotton bolls should be protected up to approximately 300 ACDD or a boll diameter of 2.5 cm. This equilibrates to bolls that are 12-14 d of age dependent upon daily maximum and minimum temperatures.

  18. Wave attenuation and mode dispersion in a waveguide coated with lossy dielectric material

    NASA Technical Reports Server (NTRS)

    Lee, C. S.; Chuang, S. L.; Lee, S. W.; Lo, Y. T.

    1984-01-01

    The modal attenuation constants in a cylindrical waveguide coated with a lossy dielectric material are studied as functions of frequency, dielectric constant, and thickness of the dielectric layer. A dielectric material best suited for a large attenuation is suggested. Using Kirchhoff's approximation, the field attenuation in a coated waveguide which is illuminated by a normally incident plane wave is also studied. For a circular guide which has a diameter of two wavelengths and is coated with a thin lossy dielectric layer (omega sub r = 9.1 - j2.3, thickness = 3% of the radius), a 3 dB attenuation is achieved within 16 diameters.

  19. Effect of Slag Impregnation on Macroscopic Deformation of Bauxite-Based Material

    NASA Astrophysics Data System (ADS)

    Coulon, Antoine; De Bilbao, Emmanuel; Michel, Rudy; Bouchetou, Marie-Laure; Brassamin, Séverine; Gazeau, Camille; Zanghi, Didier; Poirier, Jacques

    This work aims at studying the volume change of bauxite corroded by a molten slag. Cylindrical samples were prepared by mixing ground bauxite with slag. Optical measurement at high temperature (1450 °C) of deformation with a high-resolution camera has been developed. Image processing allowed for determining the change in diameter of the sample. We showed that the deformation was induced by the precipitation of new expansive crystallised phases observed by SEM-EDS analyses. Adding pellets of the same slag upon the samples allowed to emphasize the effect of the slag amount on the size change. The change in diameter significantly increased in the impregnated area.

  20. Fine woody fuel particle diameters for improved planar intersect fuel loading estimates in Southern Rocky Mountain ponderosa pine forests

    Treesearch

    Emma Vakili; Chad M. Hoffman; Robert E. Keane

    2016-01-01

    Fuel loading estimates from planar intersect sampling protocols for fine dead down woody surface fuels require an approximation of the mean squared diameter (d2) of 1-h (0-0.63 cm), 10-h (0.63-2.54 cm), and 100-h (2.54-7.62 cm) timelag size classes. The objective of this study is to determine d2 in ponderosa pine (Pinus ponderosa) forests of New Mexico and Colorado,...

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reynoso, F; Cho, S

    Purpose: To develop an external beam surrogate of the Yb-169 brachytherapy source applying a filter-based spectrum modulation technique to 250 kVp x-rays. In-vitro/vivo studies performed with the modulated 250 kVp beam will help gauge the benefits of implementing gold nanoparticle-aided radiotherapy with the Yb-169 source. Methods: A previously validated MCNP5 model of the Phillips RT-250 orthovoltage unit was used to obtain the percentage depth dose (PDD) and filtered photon spectra for a variety of filtration and irradiation conditions. Photon spectra were obtained using the average flux F4 tally in air right after all collimation. A 30 x 30 x 30more » cm{sup 3} water phantom was used to compute the PDD along the central axis (CAX) under the standards conditions of a 10 x 10 cm{sup 2} field size at 50 cm SSD. Cylindrical cells of 4 cm in diameter and the energy deposition F6 tally were used along the CAX to score the doses down to 20 cm depth. The number of particle history was set to 2 x 10{sup 8} in order to keep the relative uncertainty within each cell < 0.3%. The secondary electron spectrum within a gold-loaded tissue due to each photon spectrum was also calculated using EGSnrc and compared with that due to Yb-169 gamma rays. Results: Under the practical constraints for the spectrum modulation task, 250 kVp x-rays filtered by a 0.25 mm Erbium (Er) foil produced the best match with Yb-169 gamma rays, in terms of PDD and, more importantly, secondary electron spectrum. Conclusion: Modulation of 250kVp x-ray spectrum by an Er-filter was found effective in emulating the gamma ray spectrum of Yb-169. Possible benefits as predicted from the current MC model such as enhanced radiosensitization with the Er-filtered beam (as a surrogate of Yb-169) was confirmed with a separate in-vitro study. Supported by DOD/PCRP grant W81XWH-12-1-0198.« less

  2. SU-E-J-35: Using CBCT as the Alternative Method of Assessing ITV Volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, Y; Turian, J; Templeton, A

    2015-06-15

    Purpose To study the accuracy of Internal Target Volumes (ITVs) created on cone beam CT (CBCT) by comparing the visible target volume on CBCT to volumes (GTV, ITV, and PTV) outlined on free breathing (FB) CT and 4DCT. Methods A Quasar Cylindrical Motion Phantom with a 3cm diameter ball (14.14 cc) embedded within a cork insert was set up to simulate respiratory motion with a period of 4 seconds and amplitude of 2cm superioinferiorly and 1cm anterioposteriorly. FBCT and 4DCT images were acquired. A PTV-4D was created on the 4DCT by applying a uniform margin of 5mm to the ITV-CT.more » PTV-FB was created by applying a margin of the motion range plus 5mm, i.e. total of 1.5cm laterally and 2.5cm superioinferiorly to the GTV outlined on the FBCT. A dynamic conformal arc was planned to treat the PTV-FB with 1mm margin. A CBCT was acquired before the treatment, on which the target was delineated. During the treatment, the position of the target was monitored using the EPID in cine mode. Results ITV-CBCT and ITV-CT were measured to be 56.6 and 62.7cc, respectively, with a Dice Coefficient (DC) of 0.94 and disagreement in center of mass (COM) of 0.59 mm. On the other hand, GTV-FB was 11.47cc, 19% less than the known volume of the ball. PTV-FB and PTV-4D were 149 and 116 cc, with a DC of 0.71. Part of the ITV-CT was not enclosed by the PTV-FB despite the large margin. The cine EPID images have confirmed geometrical misses of the target. Similar under-coverage was observed in one clinical case and captured by the CBCT, where the implanted fiducials moved outside PTV-FB. Conclusion ITV-CBCT is in good agreement with ITV-CT. When 4DCT was not available, CBCT can be an effective alternative in determining and verifying the PTV margin.« less

  3. The design and performance of a prototype water Cherenkov optical time-projection chamber

    NASA Astrophysics Data System (ADS)

    Oberla, Eric; Frisch, Henry J.

    2016-04-01

    A first experimental test of tracking relativistic charged particles by 'drifting' Cherenkov photons in a water-based optical time-projection chamber (OTPC) has been performed at the Fermilab Test Beam Facility. The prototype OTPC detector consists of a 77 cm long, 28 cm diameter, 40 kg cylindrical water mass instrumented with a combination of commercial 5.1 × 5.1cm2 micro-channel plate photo-multipliers (MCP-PMT) and 6.7 × 6.7cm2 mirrors. Five MCP-PMTs are installed in two columns along the OTPC cylinder in a small-angle stereo configuration. A mirror is mounted opposite each MCP-PMT on the inner surface of the detector cylinder, effectively increasing the photo-detection efficiency and providing a time-resolved image of the Cherenkov light on the opposing wall. Each MCP-PMT is coupled to an anode readout consisting of thirty 50 Ω microstrips. A 180-channel data acquisition system digitizes the MCP-PMT signals on one end of the microstrips using the PSEC4 waveform sampling-and-digitizing chip operating at a sampling rate of 10.24 Gigasamples-per-second. The single-ended microstrip readout determines the time and position of a photon arrival at the face of the MCP-PMT by recording both the direct signal and the pulse reflected from the unterminated far end of the strip. The detector was installed on the Fermilab MCenter secondary beam-line behind a steel absorber where the primary flux is multi-GeV muons. Approximately 80 Cherenkov photons are detected for a through-going muon track in a total event duration of 2 ns. By measuring the time-of-arrival and the position of individual photons at the surface of the detector to ≤ 100 ps and a few mm, respectively, we have measured a spatial resolution of 15 mm for each MCP-PMT track segment, and, from linear fits over the entire track length of 40 cm, an angular resolution on the track direction of 60 mrad.

  4. Experimental hypervelocity impact into quartz sand - Distribution and shock metamorphism of ejecta

    NASA Technical Reports Server (NTRS)

    Stoeffler, D.; Gault, D. E.; Wedekind, J.; Polkowski, G.

    1975-01-01

    Results are presented for vertical impacts of 0.3-g cylindrical plastic projectiles into noncohesive quartz sand in which vertical and horizontal reference strate were employed by using layers of colored sand. The impacts were performed at velocities of 5.9-6.9 km/sec with a vertical gun ballistic range. The craters, 30-33 cm in diameter, reveal a radial decay of the ejecta mass per unit area with a power of -2.8 to -3.5. Material displaced from the upper 15% of the crater depth d is represented within the whole ejecta blanked, material from deeper than 28% of d is deposited inside 2 crater radii, and no material from deeper than 33% of d was ejected beyond the crater rim. Shock-metamorphosed particles (glassy agglutinates, cataclastic breccias, and comminuted quartz) amount to some 4% of the total displaced mass and indicate progressive zones of decay of shock intensity from a peak pressure of 300 kbar. The shock-metamorphosed particles and the shock-induced change in the grain size distribution of ejected samples have close analogies to the basic characteristics of the lunar regolith. Possible applications to regolith formation and to ejecta formations of large-scale impact craters are discussed.

  5. Measurement and simulation of millimeter wave scattering cross-sections from steel-reinforced concrete

    NASA Astrophysics Data System (ADS)

    Hassan, A. M.; Martys, N. S.; Garboczi, E. J.; McMichael, R. D.; Stiles, M. D.; Plusquellic, D. F.; Stutzman, P. E.; Wang, S.; Provenzano, V.; Surek, J. T.; Novotny, D. R.; Coder, J. B.; Janezic, M. D.; Kim, S.

    2014-02-01

    Some iron oxide corrosion products exhibit antiferromagnetic magnetic resonances (AFMR) at frequencies on the order of 100 GHz at ambient temperatures. AFMR can be detected in laboratory conditions, which serves as the basis for a new non-destructive spectroscopic method for detecting early corrosion. When attempting to measure the steel corrosion in reinforced concrete in the field, rebar geometry must be taken into account. Experiments and numerical simulations have been developed at frequencies near 100 GHz to sort out these effects. The experimental setup involves a vector network analyzer with converter heads to up-convert the output frequency, which is then connected to a horn antenna followed by a 7.5 cm diameter polymer lens to focus the waves on the sample. Two sets of samples were studied: uniform cylindrical rods and rebar corrosion samples broken out of concrete with different kinds of coatings. Electromagnetic scattering from uniform rods were calculated numerically using classical modal expansion. A finite-element electromagnetic solver was used to model more complex rebar geometry and non-uniform corrosion layers. Experimental and numerical data were compared to help quantify and understand the anticipated effect of local geometrical features on AFMR measurements.

  6. Damage of natural stone tablets exposed to exhaust gas under laboratory conditions

    NASA Astrophysics Data System (ADS)

    Farkas, Orsolya; Szabados, György; Török, Ákos

    2016-04-01

    Natural stone tablets were exposed to exhaust gas under laboratory conditions to assess urban stone damage. Cylindrical test specimens (3 cm in diameter) were made from travertine, non-porous limestone, porous limestone, rhyolite tuff, sandstone, andesite, granite and marble. The samples were exposed to exhaust gas that was generated from diesel engine combustion (engine type: RÁBA D10 UTSLL 160, EURO II). The operating condition of the internal combustion engine was: 1300 r/m (app 50%). The exhaust gas was diverted into a pipe system where the samples were placed perpendicular to main flow for 1, 2, 4, 8 and 10 hours, respectively. The exhaust emission was measured by using AVL particulate measurement technology; filter paper method (AVL 415). The stone samples were documented and selective parameters were measured prior to and after exhaust gas exposure. Density, volume, ultrasonic pulse velocity, mineral composition and penetration depth of emission related particulate matter were recorded. The first results indicate that after 10 hours of exposure significant amount of particulate matter deposited on the stone surface independently from the surface properties and porosity. The black soot particles uniformly covered all types of stones, making hard to differentiate the specimens.

  7. Performance Characterization of RaPToRS Systems

    NASA Astrophysics Data System (ADS)

    Shibata, K.; Krieger, M.; Fallica, J.; Henchen, R.; Pogozelski, E.; Padalino, S.; SUNY Geneseo Collaboration; LaboratoryLaser Energetics at University of Rochester Collaboration

    2011-10-01

    The Rapid Pneumatic Transport of Radioactive Samples (RaPToRS) system can quickly and efficiently move radioactive materials from their activation site to a counting station. Facilities such as the NIF and LLE are considering these systems while NRL is currently using one. The system is essentially a 10 cm diameter pneumatic tube with a cylindrical sample carrier. The performance of the system depends on many factors, including the mass of the carrier, length of the tube, angle and difference in height of the tube's endpoints, the carrier's physical design, and the number, type, and distribution of blowers attached to the tube. These factors have been systematically examined to develop the fastest and most reliable system. The most significant factors are the mass and the vertical travel of the carrier. When the carrier mass is low, moving air supports the carrier in the tube, resulting in low friction. The terminal velocity ranges from 13.5 to 2.5 m/s for masses varying from 1 kg to 3 kg. Using a single 1100 W blower, the initial force exerted on the carrier was 11.3 N. This work was supported in part by the US Department of Energy through the LLE.

  8. Magneto Rayleigh-Taylor, Sausage, and Kink Instability Experiments on a MegaAmpere Linear Transformer Driver

    NASA Astrophysics Data System (ADS)

    Yager-Elorriaga, D. A.; Steiner, A. M.; Patel, S. G.; Jordan, N. M.; Gilgenbach, R. M.; Lau, Y. Y.; Weis, M. R.; Zhang, P.

    2015-11-01

    At the Michigan Accelerator for Inductive Z-Pinch Experiments (MAIZE) facility, a 1-MA Linear Transformer Driver (LTD) is being used to deliver 500-600 kA to cylindrical liners in order to study the magneto Rayleigh-Taylor (MRT), sausage, and kink instabilities in imploding and exploding Al plasmas. The liners studied in this experiment had thicknesses of 400 nm to 30 μm, heights of 1-2 cm, and diameters of 1-6 mm. The plasmas were imaged using 4-time-frame, laser shadowgraphy and shearing-interferometry at 532 nm. For imploding liners, the measured acceleration was found to be less than predicted from the current pulse, indicating significant diffusion of the azimuthal magnetic field. A simple experimental configuration is presented for ``end-on'' laser probing in the r- θ plane in order to study the interior of the liner. Finally, the effects of axial magnetic fields are determined by modifying the return current posts and incorporating external coils. Experimental growth rates are determined and discussed. This work was supported by DOE award DE-SC0012328. S.G. Patel supported by Sandia National Labs. D.A. Yager was supported by NSF fellowship grant DGE 1256260.

  9. Evaluation of the polymerization shrinkage of experimental flowable composite resins through optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Carneiro, Vanda S. M.; Mota, Cláudia C. B. O.; Souza, Alex F.; Cajazeira, Marlus R. R.; Gerbi, Marleny E. M. M.; Gomes, Anderson S. L.

    2018-02-01

    This study evaluated the polymerization shrinkage of two experimental flowable composite resins (CR) with different proportions of Urethane dimethacrylate (UDMA)/triethylene glycol dimethacrylate (TEGDMA) monomers in the organic matrix (50:50 and 60:40, respectively). A commercially available flowable CR, Tetric N-Flow (Ivoclair Vivadent, Liechtenstein, Germany), was employed as the control group. The resins were inserted in a cylindrical teflon mold (7 mm diameter, 0.6 mm height) and scanned with OCT before photoactivation, immediately after and 15 minutes after light-curing (Radii-Cal, SDI, Australia, 1,200 mW/cm2 ) exposure. A Callisto SD-OCT system (Thorlabs Inc, USA), operating at 930 nm central wavelength was employed for imaging acquisition. Cross-sectional OCT images were captured with 8 mm transverse scanning (2000x512 matrix), and processed by the ImageJ software, for comparison between the scanning times and between groups. Pearson correlation showed significant shrinkage for all groups in each time analyzed. Kruskal-Wallis test showed greater polymerization shrinkage for the 50:50 UDMA/TEGDMA group (p=0.001), followed by the control group (p=0.018). TEGDMA concentration was proportionally related to the polymerization shrinkage of the flowable composite resins.

  10. Antarctic meteorite descriptions, 1980

    NASA Technical Reports Server (NTRS)

    Score, R.; Schwarz, C. M.; Mason, B.; Bogard, D. D.

    1982-01-01

    Specimens found in the Alan Hills area include 361 ordinary chondrites, 4 carbonaceous chondrites, 6 achondrites, and 2 irons. Thirteen specimens measured over 11 cm in diameter and 69 between 5 to 10 cm in diameter are reported. The remainder of the finds were small, and many were paired. One of the irons was estimated to weigh about 20 kilograms.

  11. Proof of the Feasibility of Coherent and Incoherent Schemes for Pumping a Gamma-ray Laser

    DTIC Science & Technology

    1992-12-31

    the Texas-X was investigated by using metallic indium disks 1.0 cm in diameter and 0.127 mm thick as well as plastic planchettes 5.0 cm in diameter and...Spectral Distribution The spectral distribution was examined by irradiating the full set of the calibration nuclides listed in Table 1. Planchettes

  12. High purity low dislocation GaAs single crystals

    NASA Technical Reports Server (NTRS)

    Chen, R. T.; Holmes, D. E.; Kirkpatrick, C. G.

    1982-01-01

    Recent advances in GaAs bulk crystal growth using the LEC (liquid encapsulated Czochralski) technique are described. The dependence of the background impurity concentration and the dislocation density distribution on the materials synthesis and growth conditions were investigated. Background impurity concentrations as low as 4 x 10 to the 15th power were observed in undoped LEC GaAs. The dislocation density in selected regions of individual ingots was very low, below the 3000 cm .3000/sq cm threshold. The average dislocation density over a large annular ring on the wafers fell below the 10000/sq cm level for 3 inch diameter ingots. The diameter control during the program advanced to a diameter variation along a 3 inch ingot less than 2 mm.

  13. Flow through internal elastic lamina affects shear stress on smooth muscle cells (3D simulations).

    PubMed

    Tada, Shigeru; Tarbell, John M

    2002-02-01

    We describe a three-dimensional numerical simulation of interstitial flow through the medial layer of an artery accounting for the complex entrance condition associated with fenestral pores in the internal elastic lamina (IEL) to investigate the fluid mechanical environment around the smooth muscle cells (SMCs) right beneath the IEL. The IEL was modeled as an impermeable barrier to water flow except for the fenestral pores, which were assumed to be uniformly distributed over the IEL. The medial layer was modeled as a heterogeneous medium composed of a periodic array of cylindrical SMCs embedded in a continuous porous medium representing the interstitial proteoglycan and collagen matrix. Depending on the distance between the IEL bottom surface and the upstream end of the proximal layer of SMCs, the local shear stress on SMCs right beneath the fenestral pore could be more than 10 times higher than that on the cells far removed from the IEL under the conditions that the fenestral pore diameter and area fraction of pores were kept constant at 1.4 microm and 0.05, respectively. Thus these proximal SMCs may experience shear stress levels that are even higher than endothelial cells exposed to normal blood flow (order of 10 dyn/cm(2)). Furthermore, entrance flow through fenestral pores alters considerably the interstitial flow field in the medial layer over a spatial length scale of the order of the fenestral pore diameter. Thus the spatial gradient of shear stress on the most superficial SMC is noticeably higher than computed for endothelial cell surfaces.

  14. Achieving quasi-adiabatic thermal environment to maximize resolution power in very high-pressure liquid chromatography: Theory, models, and experiments.

    PubMed

    Gritti, Fabrice; Gilar, Martin; Jarrell, Joseph A

    2016-04-29

    A cylindrical vacuum chamber (inner diameter 5 cm) housing a narrow-bore 2.1 mm×100 mm column packed with 1.8 μm HSS-T3 fully porous particles was built in order to isolate thermally the chromatographic column from the external air environment. Consistent with statistical physics and the mean free path of air molecules, the experimental results show that natural air convection and conduction are fully eliminated for housing air pressures smaller than 10(-4) Torr. Heat radiation is minimized by wrapping up the column with low-emissivity aluminum-tape (emissivity coefficient ϵ=0.03 vs. 0.28 for polished stainless steel 316). Overall, the heat flux at the column wall is reduced by 96% with respect to standard still-air ovens. From a practical viewpoint, the efficiency of the column run at a flow rate of 0.6 mL/min at a constant 13,000 psi pressure drop (the viscous heat power is around 9 W/m) is improved by up to 35% irrespective of the analyte retention. Models of heat and mass transfer reveal that (1) the amplitude of the radial temperature gradient is significantly reduced from 0.30 to 0.01 K and (2) the observed improvement in resolution power stems from a more uniform distribution of the flow velocity across the column diameter. The eddy dispersion term in the van Deemter equation is reduced by 0.8±0.1 reduced plate height unit, a significant gain in column performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Quantitative, nondestructive estimates of coarse root biomass in a temperate pine forest using 3-D ground-penetrating radar (GPR)

    NASA Astrophysics Data System (ADS)

    Molon, Michelle; Boyce, Joseph I.; Arain, M. Altaf

    2017-01-01

    Coarse root biomass was estimated in a temperate pine forest using high-resolution (1 GHz) 3-D ground-penetrating radar (GPR). GPR survey grids were acquired across a 400 m2 area with varying line spacing (12.5 and 25 cm). Root volume and biomass were estimated directly from the 3-D radar volume by using isometric surfaces calculated with the marching cubes algorithm. Empirical relations between GPR reflection amplitude and root diameter were determined for 14 root segments (0.1-10 cm diameter) reburied in a 6 m2 experimental test plot and surveyed at 5-25 cm line spacing under dry and wet soil conditions. Reburied roots >1.4 cm diameter were detectable as continuous root structures with 5 cm line separation. Reflection amplitudes were strongly controlled by soil moisture and decreased by 40% with a twofold increase in soil moisture. GPR line intervals of 12.5 and 25 cm produced discontinuous mapping of roots, and GPR coarse root biomass estimates (0.92 kgC m-2) were lower than those obtained previously with a site-specific allometric equation due to nondetection of vertical roots and roots <1.5 cm diameter. The results show that coarse root volume and biomass can be estimated directly from interpolated 3-D GPR volumes by using a marching cubes approach, but mapping of roots as continuous structures requires high inline sampling and line density (<5 cm). The results demonstrate that 3-D GPR is viable approach for estimating belowground carbon and for mapping tree root architecture. This methodology can be applied more broadly in other disciplines (e.g., archaeology and civil engineering) for imaging buried structures.

  16. Physical Properties of Venous Stents: An Experimental Comparison.

    PubMed

    Dabir, Darius; Feisst, Andreas; Thomas, Daniel; Luetkens, Julian A; Meyer, Carsten; Kardulovic, Ana; Menne, Matthias; Steinseifer, Ulrich; Schild, Hans H; Kuetting, Daniel L R

    2018-06-01

    Iliocaval obstruction is a substantial contributor to chronic venous insufficiency and is increasingly being treated endovascularly with angioplasty and stent placement. Utilization of an appropriate stent for treatment is pivotal; however, until today, mechanical properties of venous stents remain unknown. We analyzed the radial resistive force, the chronic outward force, as well as the crush resistance of seven stent models [Zilver Vena (Cook, Bjaeverskov, Denmark), Sinus Venous, Sinus Obliquus and Sinus XL Flex (Optimed, Ettlingen, Germany), Vici (Veniti; St. Louis, USA), Wallstent (Boston Scientific, Marlborough, USA), and Venovo (Bard, Tempe, USA)] in vitro using a radial force testing machine (RX-650, Machine Solutions Inc., Flagstaff, AZ, USA) and a hardness testing machine (zwickiLine, Zwick Roell, Ulm, Germany). The Sinus Obliquus revealed the highest radial resistive force (19.41 N/cm) and the highest chronic outward force at 50 and 30% nominal diameter (7.93 N/cm at 50%, 16.97 N/cm at 30%) while the Venovo revealed the highest chronic outward force at 90 and 80% nominal diameter (4.83 N/cm at 90%, 5.37 N/cm at 80%). The radial resistive force and the chronic outward force of the Wallstent greatly depended on whether the stent ends were fixated. The Wallstent revealed the highest crush resistance at nominal diameters of 90% (0.46 N/cm) to 60% (1.16 N/cm). The Sinus Obliquus revealed the highest crush resistance at a nominal diameter of 50% (1.41 N/cm). Venous stents greatly differ regarding their mechanical properties. These results should be considered when choosing an appropriate stent for the treatment of venous obstruction.

  17. Therapeutic analysis of high-dose-rate {sup 192}Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Hualin, E-mail: hualin.zhang@northwestern.edu; Donnelly, Eric D.; Strauss, Jonathan B.

    Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model wasmore » used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0){sup 4} to (13.4){sup 4} for the radiosensitive normal tissue depending on the cylinder size, treatment lengths, prescription depth, and dose as well. However, for a uniform cancer cell distribution, the EUDs were between 6.3 Gy × 4 and 7.1 Gy × 4, and the TRs were found to be between (1.4){sup 4} and (1.7){sup 4}. For the uniformly interspersed cancer and radio-resistant normal cells, the TRs were less than 1. The two VCBT prescription regimens were found to be equivalent in terms of EUDs and TRs. Conclusions: HDR VCBT strongly favors cylindrical target volume with the cancer cell distribution following its dosimetric trend. Assuming a half-Gaussian distribution of cancer cells, the HDR VCBT provides a considerable radiobiological advantage over the external beam radiotherapy (EBRT) in terms of sparing more normal tissues while maintaining the same level of cancer cell killing. But for the uniform cancer cell distribution and radio-resistant normal tissue, the radiobiology outcome of the HDR VCBT does not show an advantage over the EBRT. This study strongly suggests that radiation therapy design should consider the cancer cell distribution inside the target volume in addition to the shape of target.« less

  18. Progress in HTS trapped field magnets: J(sub c), area, and applications

    NASA Technical Reports Server (NTRS)

    Weinstein, Roy; Ren, Yanru; Liu, Jianxiong; Sawh, Ravi; Parks, Drew; Foster, Charles; Obot, Victor; Arndt, G. Dickey; Crapo, Alan

    1995-01-01

    Progress in trapped field magnets is reported. Single YBCO grains with diameters of 2 cm are made in production quantities, while 3 cm, 4 1/2 cm and 6 cm diameters are being explored. For single grain tiles: J(sub c) is approximately 10,000 A/cm(exp 2) for melt textured grains; J(sub c) is approximately 40,000 A/cm2 for light ion irradiation; and J(sub c) is approximately 85,000 A/cm(exp 2) for heavy ion irradiation. Using 2 cm diameter tiles bombarded by light ions, we have fabricated a mini-magnet which trapped 2.25 Tesla at 77K, and 5.3 Tesla at 65K. A previous generation of tiles, 1 cm x 1 cm, was used to trap 7.0 Tesla at 55K. Unirradiated 2.0 cm tiles were used to provide 8 magnets for an axial gap generator, in a collaborative experiment with Emerson Electric Co. This generator delivered 100 Watts to a resistive load, at 2265 rpm. In this experiment activation of the TFMs was accomplished by a current pulse of 15 ms duration. Tiles have also been studied for application as a bumper-tether system for the soft docking of spacecraft. A method for optimizing tether forces, and mechanisms of energy dissipation are discussed. A bus bar was constructed by welding three crystals while melt-texturing, such that their a,b planes were parallel and interleaved. The bus bar, an area of approximately 2 cm(exp 2), carried a transport current of 1000 amps, the limit of the testing equipment available.

  19. Use of disposable graduated biopsy forceps improves accuracy of polyp size measurements during endoscopy

    PubMed Central

    Jin, Hei-Ying; Leng, Qiang

    2015-01-01

    AIM: To determine the accuracy of endoscopic polyp size measurements using disposable graduated biopsy forceps (DGBF). METHODS: Gradations accurate to 1 mm were assessed with the wire of disposable graduated biopsy forceps. When a polyp was noted, endoscopists determined the width of the polyp; then, the graduated biopsy forceps was inserted and the largest diameter of the tumor was measured. After excision, during surgery or endoscopy, the polyp was measured using the vernier caliper. RESULTS: One hundred and thirty-three colorectal polyps from 119 patients were studied. The mean diameter, by post-polypectomy measurement, was 0.92 ± 0.69 cm; 83 were < 1 cm, 36 were between 1 and 2 cm, and 14 were > 2 cm. The mean diameter, by visual estimation, was 1.15 ± 0.88 cm; compared to the actual size measured using vernier calipers, the difference was statistically significant. The mean diameter measured using the DGBF was 0.93 ± 0.68 cm; compared to the actual size measured using vernier calipers, this difference was not statistically significant. The ratio between the mean size estimated by visual estimation and the actual size was significantly different from that between the mean size estimated using the DGBF and the actual size (1.26 ± 0.30 vs 1.02 ± 0.11). CONCLUSION: The accuracy of polyp size estimation was low by visual assessment; however, it improved when the DGBF was used. PMID:25605986

  20. Volumetric Growth of the Liver in the Human Fetus: An Anatomical, Hydrostatic, and Statistical Study

    PubMed Central

    Szpinda, Michał; Paruszewska-Achtel, Monika; Mila-Kierzenkowska, Celestyna; Elminowska-Wenda, Gabriela; Dombek, Małgorzata; Szpinda, Anna; Badura, Mateusz

    2015-01-01

    Using anatomical, hydrostatic, and statistical methods, liver volumes were assessed in 69 human fetuses of both sexes aged 18–30 weeks. No sex differences were found. The median of liver volume achieved by hydrostatic measurements increased from 6.57 cm3 at 18–21 weeks through 14.36 cm3 at 22–25 weeks to 20.77 cm3 at 26–30 weeks, according to the following regression: y = −26.95 + 1.74 × age ± Z  × (−3.15 + 0.27 × age). The median of liver volume calculated indirectly according to the formula liver volume = 0.55 × liver length × liver transverse diameter × liver sagittal diameter increased from 12.41 cm3 at 18–21 weeks through 28.21 cm3 at 22–25 weeks to 49.69 cm3 at 26–30 weeks. There was a strong relationship (r = 0.91, p < 0.001) between the liver volumes achieved by hydrostatic (x) and indirect (y) methods, expressed by y = −0.05 + 2.16x  ± 7.26. The liver volume should be calculated as follows liver volume = 0.26 × liver length × liver transverse diameter × liver sagittal diameter. The age-specific liver volumes are of great relevance in the evaluation of the normal hepatic growth and the early diagnosis of fetal micro- and macrosomias. PMID:26413551