Sample records for cm12 microscope operating

  1. Compact multi-band fluorescent microscope with an electrically tunable lens for autofocusing

    PubMed Central

    Wang, Zhaojun; Lei, Ming; Yao, Baoli; Cai, Yanan; Liang, Yansheng; Yang, Yanlong; Yang, Xibin; Li, Hui; Xiong, Daxi

    2015-01-01

    Autofocusing is a routine technique in redressing focus drift that occurs in time-lapse microscopic image acquisition. To date, most automatic microscopes are designed on the distance detection scheme to fulfill the autofocusing operation, which may suffer from the low contrast of the reflected signal due to the refractive index mismatch at the water/glass interface. To achieve high autofocusing speed with minimal motion artifacts, we developed a compact multi-band fluorescent microscope with an electrically tunable lens (ETL) device for autofocusing. A modified searching algorithm based on equidistant scanning and curve fitting is proposed, which no longer requires a single-peak focus curve and then efficiently restrains the impact of external disturbance. This technique enables us to achieve an autofocusing time of down to 170 ms and the reproductivity of over 97%. The imaging head of the microscope has dimensions of 12 cm × 12 cm × 6 cm. This portable instrument can easily fit inside standard incubators for real-time imaging of living specimens. PMID:26601001

  2. A Case Report of Human Infection with Dioctophyma Renale from Iran.

    PubMed

    Norouzi, Roghayeh; Manochehri, Arman; Hanifi, Mustafa

    2017-03-16

    A 75-year-old man from Kurdistan province, western part of Iran was diagnosed with a mass in the right kidney by ultrasound and computed tomography. In operation, a parasitic helminth, 30 cm long and 1.2 cm in diameter consistent with D. renale was found in the right kidney. Microscopic examination revealed that the male Dioctophyma renale. Following removal of worm, the symptoms completely resolved within a few hours. Generally, parasitism by D. renale in human is a necropsy finding, nevertheless imaging techniques as ultrasound and computed tomography have been proven to be important tool to achieve diagnosis.

  3. Structural analysis of ion-implanted chemical-vapor-deposited diamond by transmission electron microscope

    NASA Astrophysics Data System (ADS)

    Jiang, N.; Deguchi, M.; Wang, C. L.; Won, J. H.; Jeon, H. M.; Mori, Y.; Hatta, A.; Kitabatake, M.; Ito, T.; Hirao, T.; Sasaki, T.; Hiraki, A.

    1997-04-01

    A transmission electron microscope (TEM) study of ion-implanted chemical-vapor-deposited (CVD) diamond is presented. CVD diamond used for transmission electron microscope observation was directly deposited onto Mo TEM grids. As-deposited specimens were irradiated by C (100 keV) ions at room temperature with a wide range of implantation doses (10 12-10 17/cm 2). Transmission electron diffraction (TED) patterns indicate that there exists a critical dose ( Dc) for the onset of amorphization of CVD diamond as a result of ion induced damage and the value of critical dose is confirmed to be about 3 × 10 15/cm 2. The ion-induced transformation process is clearly revealed by high resolution electron microscope (HREM) images. For a higher dose implantation (7 × 10 15/cm 2) a large amount of diamond phase is transformed into amorphous carbon and many tiny misoriented diamond blocks are found to be left in the amorphous solid. The average size of these misoriented diamond blocks is only about 1-2 nm. Further bombardment (10 17/cm 2) almost kills all of the diamond phase within the irradiated volume and moreover leads to local formation of micropolycrystalline graphite.

  4. Operational Test Instrumentation Guide.

    DTIC Science & Technology

    1981-11-01

    Water Vapor 1 oz/100 in2/day +0.02 gm/100 Transmission (25 gm/645 cm2 /day) in2/day H-12 Parameter Range Accuracy Corrosion Weight Loss Unlimited +10 mg...Abrasion Resistance Unlimited ( weight loss ) +10 mg Metallographic Microscope up to 1,500X Magnification Examination Rockwell Hardness Any +1 point...S-band conversion is possible in approximately 30 days. b Limitations. (o Large data errors at elevation angles below 3 degrees. A-21 o Loss of

  5. Invasive vulvar carcinoma and the question of the surgical margin.

    PubMed

    Palaia, Innocenza; Bellati, Filippo; Calcagno, Marco; Musella, Angela; Perniola, Giorgia; Panici, Pierluigi B

    2011-08-01

    To assess the discrepancy between width of surgical margin measured with the naked eye/ruler by a surgeon before removing an invasive vulvar carcinoma, and width of margin measured under microscope by pathologist after fixation of the resected lesion with formalin. Potential relationships between discrepancy and disease recurrence were also investigated. This prospective study was conducted with resected lesions from 86 women who underwent surgery for primary/recurrent invasive vulvar carcinoma. After the surgeon removed the lesions surrounded by 1-2-cm margins, the pathologist determined margin width at the 4 cardinal points of 86 lesions (for a total of 344 margin assessments), first macroscopically and then under the microscope. A safety margin of 0.8 cm on microscopic view was achieved in 83% of cases (112 of 135) when the macroscopic measurement was 1cm, in 91% of cases (58 of 64) when it was 1.5 cm, and 98% of cases (105 of 107) when it was 2 cm. There was a small discrepancy between the surgeon's intent and the microscopic margin measurement, mostly related to tissue shrinkage. A 1-cm surgical margin corresponded to a 0.8-cm margin in microscopic view (the "safe margin") in most cases. Copyright © 2011 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  6. Comparison of surgical outcomes after anterior cervical discectomy and fusion: does the intra-operative use of a microscope improve surgical outcomes.

    PubMed

    Adogwa, Owoicho; Elsamadicy, Aladine; Reiser, Elizabeth; Ziegler, Cole; Freischlag, Kyle; Cheng, Joseph; Bagley, Carlos A

    2016-03-01

    The primary aim of this study was to assess and compare the complications profile as well as long-term clinical outcomes between patients undergoing an Anterior Cervical Discectomy and Fusion (ACDF) procedure with and without the use of an intra-operative microscope. One hundred and forty adult patients (non-microscope cohort: 81; microscope cohort: 59) undergoing ACDF at a major academic medical center were included in this study. Enrollment criteria included available demographic, surgical and clinical outcome data. All patients had prospectively collected patient-reported outcomes measures and a minimum 2-year follow-up. Patients completed the neck disability index (NDI), short-form 12 (SF-12) and visual analog pain scale (VAS) before surgery, then at 3, 6, 12, and 24 months after surgery. Clinical outcomes and complication rates were compared between both patient cohorts. Baseline characteristics were similar between both cohorts. The mean ± standard deviation duration of surgery was longer in the microscope cohort (microscope: 169±34 minutes vs. non-microscope: 98±42 minutes, P<0.001). There was no significant difference between cohorts in the incidence of nerve root injury (P=0.99) or incidental durotomy (P=0.32). At 3 months post-operatively, both cohorts demonstrated similar improvement in VAS-neck pain (P=0.69), NDI (P=0.86), SF-12 PCS (P=0.84) and SF-12 MCS (P=0.75). At 2-year post-operatively, both the microscope and non-microscope cohorts demonstrated similar improvement from base line in NDI (microscope: 13.52±25.77 vs. non-microscope: 19.51±27.47, P<0.18), SF-12 PCS (microscope: 4.15±26.39 vs. non-microscope: 11.98±22.96, P<0.07), SF-12 MCS (microscope: 9.47±32.38 vs. non-microscope: 16.19±30.44, P<0.21). Interestingly at 2 years, the change in VAS neck pain score was significantly different between cohorts (microscope: 2.22±4.00 vs. non-microscope: 3.69±3.61, P<0.02). Our study demonstrates that the intra-operative use of a microscope does not improve overall surgery-related outcomes, nor does it lead to superior long-term outcomes in pain and functional disability, 2 years after index surgery.

  7. Comparison of surgical outcomes after anterior cervical discectomy and fusion: does the intra-operative use of a microscope improve surgical outcomes

    PubMed Central

    Elsamadicy, Aladine; Reiser, Elizabeth; Ziegler, Cole; Freischlag, Kyle; Cheng, Joseph; Bagley, Carlos A.

    2016-01-01

    Background The primary aim of this study was to assess and compare the complications profile as well as long-term clinical outcomes between patients undergoing an Anterior Cervical Discectomy and Fusion (ACDF) procedure with and without the use of an intra-operative microscope. Methods One hundred and forty adult patients (non-microscope cohort: 81; microscope cohort: 59) undergoing ACDF at a major academic medical center were included in this study. Enrollment criteria included available demographic, surgical and clinical outcome data. All patients had prospectively collected patient-reported outcomes measures and a minimum 2-year follow-up. Patients completed the neck disability index (NDI), short-form 12 (SF-12) and visual analog pain scale (VAS) before surgery, then at 3, 6, 12, and 24 months after surgery. Clinical outcomes and complication rates were compared between both patient cohorts. Results Baseline characteristics were similar between both cohorts. The mean ± standard deviation duration of surgery was longer in the microscope cohort (microscope: 169±34 minutes vs. non-microscope: 98±42 minutes, P<0.001). There was no significant difference between cohorts in the incidence of nerve root injury (P=0.99) or incidental durotomy (P=0.32). At 3 months post-operatively, both cohorts demonstrated similar improvement in VAS-neck pain (P=0.69), NDI (P=0.86), SF-12 PCS (P=0.84) and SF-12 MCS (P=0.75). At 2-year post-operatively, both the microscope and non-microscope cohorts demonstrated similar improvement from base line in NDI (microscope: 13.52±25.77 vs. non-microscope: 19.51±27.47, P<0.18), SF-12 PCS (microscope: 4.15±26.39 vs. non-microscope: 11.98±22.96, P<0.07), SF-12 MCS (microscope: 9.47±32.38 vs. non-microscope: 16.19±30.44, P<0.21). Interestingly at 2 years, the change in VAS neck pain score was significantly different between cohorts (microscope: 2.22±4.00 vs. non-microscope: 3.69±3.61, P<0.02). Conclusions Our study demonstrates that the intra-operative use of a microscope does not improve overall surgery-related outcomes, nor does it lead to superior long-term outcomes in pain and functional disability, 2 years after index surgery. PMID:27683692

  8. Very low risk of light-induced retinal damage during Boston keratoprosthesis surgery: a rabbit study.

    PubMed

    Salvador-Culla, Borja; Behlau, Irmgard; Sayegh, Rony R; Stacy, Rebecca C; Dohlman, Claes H; Delori, François

    2014-02-01

    The aim of this study was to assess the possibility of light damage to the retina by a surgical microscope during implantation of a Boston Keratoprosthesis (B-KPro) in rabbits. The retinal irradiance from a Zeiss OPMI Lumera S7 operating microscope was measured at the working distance (16.5 cm). Light transmittance through an isolated B-KPro was measured. A B-KPro was implanted into 1 eye of 12 rabbits with the optic covered during the procedure. The operated eyes were then continuously exposed to a fixed light intensity under the microscope for 1 hour. Fluorescein angiography was carried out on days 2 and 9 postsurgery, after which the animals were euthanized. Further, we compared the potential of these retinal exposures to well-accepted light safety guidelines applicable to humans. Light transmittance of B-KPro revealed a blockage of short wavelengths (<390 nm) and of long wavelengths (1660-1750 nm) of light. In addition, the surgical microscope filtered a part of the blue, ultraviolet, and infrared wavelengths. Neither fluorescein angiography nor a histological examination showed any morphological retinal changes in our rabbits. Moreover, the retinal exposures were well below the safety limits. Modern surgical microscopes have filters incorporated in them that block the most damaging wavelengths of light. The B-KPro is made of 100% poly(methyl methacrylate), which makes it in itself a blocker of short wavelengths of light. No damage could be demonstrated in the animal study, and the retinal exposures were well below the safety limits. Together, these results suggest that light exposures during B-KPro surgery present a low risk of photochemical damage to the retina.

  9. Thermal effects of white light illumination during microsurgery: clinical pilot study on the application safety of surgical microscopes.

    PubMed

    Hibst, Raimund; Saal, David; Russ, Detlef; Kunzi-Rapp, Karin; Kienle, Alwin; Stock, Karl

    2010-01-01

    Modern operating microscopes offer high power illumination to ensure optimal visualization, but can also cause thermal damage. The aim of our study is to quantify the thermal effects in vivo and discuss conditions for safe use. In a pilot study on volunteers, we measured the temperature at the skin surface during microscope illumination, including the influence of anaesthesia and the effects of staining, draping, or moistening of the skin. Irradiation within the limit given by safety regulations (200 mW/cm(2)) results in skin surface temperature of 43 degrees C. Higher intensities (forearm 335 mW/cm(2), back 250 mW/cm(2)) are tolerated, resulting in reversible hyperaemia. At a very high illumination intensity (750 mW/cm(2)), pain occurs within 30 s at temperatures of 46 degrees C+/-1 degrees C (hand and forearm), and 43 degrees C+/-2 degrees C (back), respectively. Anaesthesia has no distinct effect on the temperature, whereas staining and drapes result in much higher temperatures (>100 degrees C). Moistening at practicable flow rates can reduce temperature efficiently when combined with a light absorbing and water absorbent drape. In conclusion, surgeons must be aware that surgical microscope illumination without protective means can cause skin temperatures to rise much above pain threshold, which in our study serves as a (conservative) benchmark for potential damage.

  10. Thermal effects of white light illumination during microsurgery: clinical pilot study on the application safety of surgical microscopes

    NASA Astrophysics Data System (ADS)

    Hibst, Raimund; Saal, David; Russ, Detlef; Kunzi-Rapp, Karin; Kienle, Alwin; Stock, Karl

    2010-07-01

    Modern operating microscopes offer high power illumination to ensure optimal visualization, but can also cause thermal damage. The aim of our study is to quantify the thermal effects in vivo and discuss conditions for safe use. In a pilot study on volunteers, we measured the temperature at the skin surface during microscope illumination, including the influence of anaesthesia and the effects of staining, draping, or moistening of the skin. Irradiation within the limit given by safety regulations (200 mW/cm2) results in skin surface temperature of 43 °C. Higher intensities (forearm 335 mW/cm2, back 250 mW/cm2) are tolerated, resulting in reversible hyperaemia. At a very high illumination intensity (750 mW/cm2), pain occurs within 30 s at temperatures of 46 °C+/-1 °C (hand and forearm), and 43 °C+/-2 °C (back), respectively. Anaesthesia has no distinct effect on the temperature, whereas staining and drapes result in much higher temperatures (>100 °C). Moistening at practicable flow rates can reduce temperature efficiently when combined with a light absorbing and water absorbent drape. In conclusion, surgeons must be aware that surgical microscope illumination without protective means can cause skin temperatures to rise much above pain threshold, which in our study serves as a (conservative) benchmark for potential damage.

  11. Infrared Pyrometry From Room Temperature To 700 Degrees C

    NASA Technical Reports Server (NTRS)

    Wheeler, Donald R.; Jones, William R., Jr.; Pepper, Stephen V.

    1989-01-01

    Consistent readings obtained when specimens prepared appropriately. New method largely overcomes limitations. Transmission of infrared increased by replacing customary metal-coated glass viewing port with quartz viewing port covered with tantalum mesh. Commercially available infrared microscope with focal distance of 53 cm focuses on spot only 1 mm wide on specimen. Microscope operated as radiometer. Output of detector varies by several orders of magnitude, processed by logarithmic amplifier before reading.

  12. Effect of operating microscope light on brain temperature during craniotomy.

    PubMed

    Gayatri, Parthasarathi; Menon, Girish G; Suneel, Puthuvassery R

    2013-07-01

    Operating microscopes used during neurosurgery are fitted with xenon light. Burn injuries have been reported because of xenon microscope lighting as the intensity of xenon light is 300 W. We designed this study to find out if the light of operating microscope causes an increase in temperature of the brain tissue, which is exposed underneath. Twenty-one adult patients scheduled for elective craniotomies were enrolled. Distal esophageal temperature (T Eso), brain temperature under the microscope light (T Brain), and brain temperature under dura mater (T Dura) were measured continuously at 15-minute intervals during microscope use. The irrigation fluid temperature, room temperature, intensity of the microscope light, and the distance of the microscope from the brain surface were kept constant. The average age of the patients was 44±15 years (18 males and 3 females). The mean duration of microscope use was 140±39 minutes. There were no significant changes in T Brain and T Dura and T Eso over time. T Dura was significantly lower than T Brain both at time 0 and 60 minutes but not at 90 minutes. T Brain was significantly lower than T Eso both at time 0 and 60 minutes but not at 90 minutes. The T Dura remained significantly lower than T Eso at 0, 60, and 90 minutes. Our study shows that there is no significant rise in brain temperature under xenon microscope light up to 120 minutes duration, at intensity of 60% to 70%, from a distance of 20 to 25 cm from the brain surface.

  13. Collaborative Research and Development (CR&D). Delivery Order 0051: Atomic Scale Transmission Electron Microscope Image Modeling and Application to Semiconductor Heterointerface Characterization

    DTIC Science & Technology

    2008-01-01

    information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD...microscopy ( AEM ), to characterize a variety of III-V semiconductor thin films. The materials investigated include superlattices based on the InAs- GaSb...technique. TEM observations were performed using a Philips-CM 200 FEG transmission electron microscope equipped with a field emission gun, operated at an

  14. Resonant Cavity Enhanced On-Chip Raman Spectrometer Array with Precisely Positioned Metallic Nano-Gaps for Single Molecule Detection

    DTIC Science & Technology

    2011-03-22

    the nanogaps are engraved on. Simulations show that smaller diameters of the nanowires should provide higher enhancement factors for SERS signal...Inverted Microscope with lasers of wavelengths of 512 to 633 nm as the excitation source. The signal was collected and analyzed by a 50cm Spectrometer...the optical path which can selectively pass the Raman signals and reject the excitation lasers . Figure 2.12 Custom built Raman microscope for the

  15. Confocal Raman microscopy and multivariate statistical analysis for determination of different penetration abilities of caffeine and propylene glycol applied simultaneously in a mixture on porcine skin ex vivo.

    PubMed

    Mujica Ascencio, Saul; Choe, ChunSik; Meinke, Martina C; Müller, Rainer H; Maksimov, George V; Wigger-Alberti, Walter; Lademann, Juergen; Darvin, Maxim E

    2016-07-01

    Propylene glycol is one of the known substances added in cosmetic formulations as a penetration enhancer. Recently, nanocrystals have been employed also to increase the skin penetration of active components. Caffeine is a component with many applications and its penetration into the epidermis is controversially discussed in the literature. In the present study, the penetration ability of two components - caffeine nanocrystals and propylene glycol, applied topically on porcine ear skin in the form of a gel, was investigated ex vivo using two confocal Raman microscopes operated at different excitation wavelengths (785nm and 633nm). Several depth profiles were acquired in the fingerprint region and different spectral ranges, i.e., 526-600cm(-1) and 810-880cm(-1) were chosen for independent analysis of caffeine and propylene glycol penetration into the skin, respectively. Multivariate statistical methods such as principal component analysis (PCA) and linear discriminant analysis (LDA) combined with Student's t-test were employed to calculate the maximum penetration depths of each substance (caffeine and propylene glycol). The results show that propylene glycol penetrates significantly deeper than caffeine (20.7-22.0μm versus 12.3-13.0μm) without any penetration enhancement effect on caffeine. The results confirm that different substances, even if applied onto the skin as a mixture, can penetrate differently. The penetration depths of caffeine and propylene glycol obtained using two different confocal Raman microscopes are comparable showing that both types of microscopes are well suited for such investigations and that multivariate statistical PCA-LDA methods combined with Student's t-test are very useful for analyzing the penetration of different substances into the skin. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Apparatus for measuring Seebeck coefficient and electrical resistivity of small dimension samples using infrared microscope as temperature sensor.

    PubMed

    Jaafar, W M N Wan; Snyder, J E; Min, Gao

    2013-05-01

    An apparatus for measuring the Seebeck coefficient (α) and electrical resistivity (ρ) was designed to operate under an infrared microscope. A unique feature of this apparatus is its capability of measuring α and ρ of small-dimension (sub-millimeter) samples without the need for microfabrication. An essential part of this apparatus is a four-probe assembly that has one heated probe, which combines the hot probe technique with the Van der Pauw method for "simultaneous" measurements of the Seebeck coefficient and electrical resistivity. The repeatability of the apparatus was investigated over a temperature range of 40 °C-100 °C using a nickel plate as a standard reference. The results show that the apparatus has an uncertainty of ±4.9% for Seebeck coefficient and ±5.0% for electrical resistivity. The standard deviation of the apparatus against a nickel reference sample is -2.43 μVK(-1) (-12.5%) for the Seebeck coefficient and -0.4 μΩ cm (-4.6%) for the electrical resistivity, respectively.

  17. Ice crystal growth in a dynamic thermal diffusion chamber

    NASA Technical Reports Server (NTRS)

    Keller, V. W.

    1980-01-01

    Ice crystals were grown in a supersaturated environment produced by a dynamic thermal diffusion chamber, which employed two horizontal plates separated by a distance of 2.5 cm. Air was circulated between and along the 1.2 m length of the plates past ice crystals which nucleated and grew from a fiber suspended vertically between the two plates. A zoom stereo microscope with a magnification which ranged from 3X to 80X and both 35 mm still photographs and 16 mm time lapse cine films taken through the microscope were used to study the variation of the shape and linear growth rate of ice crystals as a function of the ambient temperature, the ambient supersaturation, and the forced ventilation velocity. The ambient growth conditions were varied over the range of temperature 0 to -40 C, over the range of supersaturation 4% to 50% with respect to ice, and over the range of forced ventilation velocities 0 cm/s to 20 cm/s.

  18. Real-time restoration of white-light confocal microscope optical sections

    PubMed Central

    Balasubramanian, Madhusudhanan; Iyengar, S. Sitharama; Beuerman, Roger W.; Reynaud, Juan; Wolenski, Peter

    2009-01-01

    Confocal microscopes (CM) are routinely used for building 3-D images of microscopic structures. Nonideal imaging conditions in a white-light CM introduce additive noise and blur. The optical section images need to be restored prior to quantitative analysis. We present an adaptive noise filtering technique using Karhunen–Loéve expansion (KLE) by the method of snapshots and a ringing metric to quantify the ringing artifacts introduced in the images restored at various iterations of iterative Lucy–Richardson deconvolution algorithm. The KLE provides a set of basis functions that comprise the optimal linear basis for an ensemble of empirical observations. We show that most of the noise in the scene can be removed by reconstructing the images using the KLE basis vector with the largest eigenvalue. The prefiltering scheme presented is faster and does not require prior knowledge about image noise. Optical sections processed using the KLE prefilter can be restored using a simple inverse restoration algorithm; thus, the methodology is suitable for real-time image restoration applications. The KLE image prefilter outperforms the temporal-average prefilter in restoring CM optical sections. The ringing metric developed uses simple binary morphological operations to quantify the ringing artifacts and confirms with the visual observation of ringing artifacts in the restored images. PMID:20186290

  19. Mid-infrared Study of Stones from the Sutters Mill Meteorite

    NASA Technical Reports Server (NTRS)

    Nuevo, Michel; Sandford, Scott A.; Flynn, George; Wirick, Sue

    2013-01-01

    The Sutter's Mill meteorite fell in northern California on April 22, 2012, and numerous pieces have been recovered and studied with several analytical techniques [1]. We present a Fourier-transform infrared (FTIR) spectroscopy analysis of fragments from several stones of the meteorite. Methods and analysis: Infrared spectra of samples SM2 and SM12 were recorded with a Nicolet iN10 MX FTIR microscope in the mid-IR range (4000-650/cm; spectral resolution 4/cm), while samples SM20 and SM30 were analyzed with a synchrotron-based Nicolet Continuum IR microscope in the same range. Samples were deposited on a clean glass slide, crushed with either a stainless steel roller tool or between 2 slides, and placed directly on the focal plane of the microscopes. Results: IR spectra of non-fusion crust samples show several absorption features associated with minerals such as olivines, phyllosilicates, carbonates (calcite and dolomite), and pyroxenes, as well as organics [2]. The carbonates display a main, broad band centered at 1433/cm, with additional bands at 2515/cm, 1797/cm, 882/cm, and 715/cm. Features associated with phyllosilicates include a symmetric Si-O stretching mode band centered at 1011/cm and several O-H stretching mode bands?a broad band centered at 3415/cm that is probably due to adsorbed H2O, and occasionally a much weaker, narrower feature centered near 3680/cm due to structural O-H. Features observed in the 2985-2855/cm range suggest the presence of aliphatic -CH3 and -CH2- groups. However, some of these bands show unusual relative intensities, mainly because of carbonate overtone bands that fall in the same spectral range, which can make the identification of C-H stretching bands problematic. The positions and relative strengths of the aliphatic -CH2- and -CH3 features, where they can be distinguished from overlapping carbonate bands, are consistent with those in interplanetary dust particles (IDPs) and Murchison. Finally, the absence of a strong C=O absorption feature near 1700/cm distinguishes the organics in the Sutter's Mill meteorite from that in most IDPs and in Murchison, but is consistent with the organic matter in Tagish Lake.

  20. Changes in quantity and spectroscopic properties of water-extractable organic matter during soil aquifer treatment.

    PubMed

    Xue, S; Zhao, Q L; Wei, L L; Ma, X P; Tie, M

    2013-01-01

    The aim of this study was to identify qualitative and quantitative changes in the character of water-extractable organic matter (WEOM) in soils as a consequence of soil aquifer treatment (SAT). Soil samples were obtained from a soil-column system with a 2-year operation, and divided into seven layers from top to bottom: CS1 (0-12.5 cm), CS2 (12.5-25 cm), CS3 (25-50 cm), CS4 (50-75 cm), CS5 (75-100 cm), CS6 (100-125 cm) and CS7 (125-150 cm). A sample of the original soil used to pack the columns was also analysed to determine the effects of SAT. Following 2 years of SAT operation, both soil organic carbon and water-extractable organic carbon were shown to accumulate in the top soil layer (0-12.5 cm), and to decrease in soil layers deeper than 12.5 cm. The WEOM in the top soil layer was characterized by low aromaticity index (AI), low emission humification index (HIX) and low fluorescence efficiency index (F(eff)). On the other hand, the WEOM in soil layers deeper than 12.5 cm had increased values of HIX and F(eff), as well as decreased AI values relative to the original soil before SAT. In all soil layers, the percentage of hydrophobic and transphilic fractions decreased, while that of the hydrophilic fraction increased, as a result of SAT. The production of the amide-2 functional groups was observed in the top soil layer. SAT operation also led to the enrichment of hydrocarbon and amide-1 functional groups, as well as the depletion of oxygen-containing functional groups in soil layers deeper than 12.5 cm.

  1. Liquid-phase epitaxy grown PbSnTe distributed feedback laser diodes with broad continuous single-mode tuning range

    NASA Technical Reports Server (NTRS)

    Hsieh, H.-H.; Fonstad, C. G.

    1980-01-01

    Distributed feedback (DFB) pulsed laser operation has been demonstrated in stripe geometry Pb(1-x)Sn(x)Te double-heterostructures grown by liquid-phase epitaxy. The grating structure of 0.79 micron periodicity operates in first order near 12.8 microns and was fabricated prior to the liquid-phase epitaxial growth using holographic exposure techniques. These DFB lasers had moderate thresholds, 3.6 kA/sq cm, and the output power versus current curves exhibited a sharp turn-on free of kinks. Clean, single-mode emission spectra, continuously tunable over a range in excess of 20 per cm, centered about 780 per cm (12.8 microns), and at an average rate of 1.2 per cm-K from 9 to 26 K, were observed. While weaker modes could at times be seen in the spectrum, substantially single-mode operation was obtained over the entire operating range and to over 10 times threshold.

  2. Endocardial fibrosarcoma in a reticulated python (Python reticularis).

    PubMed

    Gumber, Sanjeev; Nevarez, Javier G; Cho, Doo-Youn

    2010-11-01

    A female, reticulated python (Python reticularis) of unknown age was presented with a history of lethargy, weakness, and distended coelom. Physical examination revealed severe dystocia and stomatitis. The reticulated python was euthanized due to a poor clinical prognosis. Postmortem examination revealed marked distention of the reproductive tract with 26 eggs (10-12 cm in diameter), pericardial effusion, and a slightly firm, pale tan mass (3-4 cm in diameter) adhered to the endocardium at the base of aorta. Based on histopathologic and transmission electron microscopic findings, the diagnosis of endocardial fibrosarcoma was made.

  3. Performance capabilities of the 12-centimeter Xenon ion thruster

    NASA Technical Reports Server (NTRS)

    Mantenieks, M.; Schatz, M.

    1984-01-01

    The 8- and 12-cm mercury ion thruster systems were developed primarily to provide N-S station keeping of satellites with masses up to about 1800 to 3600 kg respectively. The on-orbit propulsion requirements of recently proposed Large Space Systems (LSS) are beyond the thrust capabilities of the baseline 8- and 12-cm thruster systems. This paper presents a characterization of the performance capabilities of the 12-cm Xenon ion thruster to enable an evaluation of its application to LSS auxiliary propulsion requirements. With minor thruster modifications and simplifications the thrust was increased to 64 mN, a factor of six over the baseline 12-cm mercury thruster performance. The thruster was operated over a range of specific impulse of about 2000 to 4000 seconds and at total efficiencies up to 68.0 percent. The operating levels reached in this study were found to be close to the operating limits of the thruster design in terms of perveance, grid breakdown voltage and thruster component temperatures such as those of the magnets and cathode baffle.

  4. A Comparison of Coronal Tooth Discoloration Elicited by Various Endodontic Reparative Materials

    DTIC Science & Technology

    2015-06-17

    operating microscope at 12.8x magnification to be completely intact and free of restorations, cracks , and/or defects. Each tooth was stored separately in...microscope. The buccal enamel -dentin thickness was standardized to 3mm using spring calipers. Teeth were irrigated with 6% NaOCl and dried. All

  5. Correlation of hemorrhage, axonal damage, and blood-tissue barrier disruption in brain and retina of Malawian children with fatal cerebral malaria.

    PubMed

    Greiner, Jesse; Dorovini-Zis, Katerina; Taylor, Terrie E; Molyneux, Malcolm E; Beare, Nicholas A V; Kamiza, Steve; White, Valerie A

    2015-01-01

    The retinal and brain histopathological findings in children who died from cerebral malaria (CM) have been recently described. Similar changes occur in both structures, but the findings have not been directly compared in the same patients. In this study, we compared clinical retinal findings and retinal and cerebral histopathological changes in a series of patients in Blantyre, Malawi, who died of CM. The features systematically compared in the same patient were: (1) clinical, gross and microscopic retinal hemorrhages with microscopic cerebral hemorrhages, (2) retinal and cerebral hemorrhage-associated and -unassociated axonal damage, and fibrinogen leakage, and (3) differences in the above features between the pathological categories of CM without microvascular pathology (CM1) and CM with microvascular pathology (CM2) in retina and brain. Forty-seven patients were included: seven CM1, 28 CM2, and 12 controls. In the 35 malaria cases retinal and cerebral pathology correlated in all features except for non-hemorrhage associated fibrinogen leakage. Regarding CM1 and CM2 cases, the only differences were in the proportion of patients with hemorrhage-associated cerebral pathology, and this was expected, based on the definitions of CM1 and CM2. The retina did not show this difference. Non-hemorrhage associated pathology was similar for the two groups. As postulated, histopathological features of hemorrhages, axonal damage and non-hemorrhage associated fibrinogen leakage correlated in the retina and brain of individual patients, although the difference in hemorrhages between the CM1 and CM2 groups was not consistently observed in the retina. These results help to underpin the utility of ophthalmoscopic examination and fundus findings to help in diagnosis and assessment of cerebral malaria patients, but may not help in distinguishing between CM1 and CM2 patients during life.

  6. Fluorescein-guided surgery for grade IV gliomas with a dedicated filter on the surgical microscope: preliminary results in 12 cases.

    PubMed

    Acerbi, Francesco; Broggi, Morgan; Eoli, Marica; Anghileri, Elena; Cuppini, Lucia; Pollo, Bianca; Schiariti, Marco; Visintini, Sergio; Orsi, Chiara; Franzini, Angelo; Broggi, Giovanni; Ferroli, Paolo

    2013-07-01

    Fluorescein is widely used as a fluorescent tracer for many applications. Its capability to accumulate in cerebral areas with blood-brain barrier damage makes it an ideal dye for intraoperative visualization of malignant gliomas (MG). We report our preliminary experience in fluorescein-guided removal of grade IV gliomas using a dedicated filter on the surgical microscope. In September 2011 we started a prospective phase II trial (FLUOGLIO) to evaluate the safety and obtain initial indications about the efficacy of fluorescein-guided surgery for MG. Patients with suspected MG amenable to complete resection of contrast-enhancing areas were eligible to participate in this study. This report is based on a preliminary analysis of the results of 12 patients with grade IV gliomas out of 15 consecutive cases (age range 48-72 years) enrolled since September 2011. Fluorescein was injected intravenously (i.v.) after intubation (5-10 mg/kg). The tumor was removed using a microsurgical technique and fluorescence visualization by BLU 400 or YELLOW 560 filters on a Pentero microscope (Carl Zeiss, Germany). The study was approved by our ethics committee and registered on the European Regulatory Authorities website (EudraCT no. 2011-002527-18). Histological analysis confirmed grade IV gliomas in 12/15 cases. Median preoperative tumor volume was 33.15 cm(3) (9.6-87.8 cm(3)). No adverse reaction related to the administration of fluorescein was registered. Contrast-enhanced tumor was completely removed in 75 % of the patients. This preliminary analysis suggested that the use of intravenous fluorescein during surgery on grade IV gliomas is safe and allows a high rate of complete resection of contrast-enhanced tumor at the early postoperative MRI.

  7. Confirmation of thalamosubthalamic projections by electron microscopic autoradiography.

    PubMed

    Sugimoto, T; Hattori, T

    1983-05-16

    Direct projections from the centre median-parafascicular complex (CM-Pf) to the subthalamic nucleus(STN) were confirmed by electron microscopic autoradiography. [3H]Leucine injections into the rat CM-Pf produced preferential labeling of Gray's type I boutons containing round vesicles in the ipsilateral STN. Further results strongly suggested the existence of some common CM-Pf projections to both the striatum and STN.

  8. Scanning MWCNT-Nanopipette and Probe Microscopy: Li Patterning and Transport Studies.

    PubMed

    Larson, Jonathan M; Bharath, Satyaveda C; Cullen, William G; Reutt-Robey, Janice E

    2015-10-07

    A carbon-nanotube-enabling scanning probe technique/nanotechnology for manipulating and measuring lithium at the nano/mesoscale is introduced. Scanning Li-nanopipette and probe microscopy (SLi-NPM) is based on a conductive atomic force microscope (AFM) cantilever with an open-ended multi-walled carbon nanotube (MWCNT) affixed to its apex. SLi-NPM operation is demonstrated with a model system consisting of a Li thin film on a Si(111) substrate. By control of bias, separation distance, and contact time, attograms of Li can be controllably pipetted to or from the MWCNT tip. Patterned surface Li features are then directly probed via noncontact AFM measurements with the MWCNT tip. The subsequent decay of Li features is simulated with a mesoscale continuum model, developed here. The Li surface diffusion coefficient for a four (two) Li layer thick film is measured as D=8(±1.2)×10(-15) cm(2) s(-1) (D=1.75(±0.15)×10(-15) cm(2) s(-1)). Dual-Li pipetting/measuring with SLi-NPM enables a broad range of time-dependent Li and nanoelectrode characterization studies of fundamental importance to energy-storage research. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Solid state photomultiplier for astronomy, phase 2

    NASA Technical Reports Server (NTRS)

    Besser, P. J.; Hays, K. M.; Laviolette, R. A.

    1989-01-01

    Epitaxial layers with varying donor concentration profiles were grown on silicon substrate wafers using chemical vapor deposition (CVD) techniques, and solid state photomultiplier (SSPM) devices were fabricated from the wafers. Representative detectors were tested in a low background photon flux, low temperature environment to determine the device characteristics for comparison to NASA goals for astronomical applications. The SSPM temperatures varied between 6 and 11 K with background fluxes in the range from less than 5 x 10 to the 6th power to 10 to the 13th power photons/square cm per second at wavelengths of 3.2 and 20 cm. Measured parameters included quantum efficiency, dark count rate and bias current. Temperature for optimal performance is 10 K, the highest ever obtained for SSPMs. The devices exhibit a combination of the lowest dark current and highest quantum efficiency yet achieved. Experimental data were reduced, analyzed and used to generate recommendations for future studies. The background and present status of the microscopic theory of SSPM operation were reviewed and summarized. Present emphasis is on modeling of the avalanche process which is the basis for SSPM operation. Approaches to the solution of the Boltzmann transport equation are described and the treatment of electron scattering mechanisms is presented. The microscopic single-electron transport theory is ready to be implemented for large-scale computations.

  10. Variations of melatonin and stress hormones under extended shifts and radiofrequency electromagnetic radiation.

    PubMed

    Vangelova, Katia Koicheva; Israel, Mishel Salvador

    2005-01-01

    We studied the time-of-day variations in urinary levels of 6-sulphatoxy-melatonin and three stress hormones in operators working fast-rotating extended shifts under radiofrequency electromagnetic radiation (EMR). The excretion rate of the hormones was monitored by radioimmunoassay and spectrofluorimetry at 4-hour intervals in a group of 36 male operators comprising 12 broadcasting station operators, 12 TV station operators, and a control group of 12 satellite station operators. Measuring the time-weighted average (TWA) of EMR exposure revealed a high-level of exposure in broadcasting station operators (TWAmean= 3.10 microW/ cm2, TWAmax = 137.00 microW/cm2), a low-level in TV station operators (TWAmean = 1.89 microW/cm2, TWAmax = 5.24 microW/cm2), and a very low level in satellite station operators. The differences among the groups remained the same after confounding factors were taken into account. Radiofrequency EMR had no effect on the typical diurnal pattern of 6-sulphatoxymelatonin. High-level radiofrequency EMR exposure significantly increased the excretion rates of cortisol (p < 0.001), adrenaline (p = 0.028), and noradrenaline (p < 0.000), whereas changes under low-level exposure did not reach significance. The 24-hour excretion of cortisol and noradrenaline correlated with TWAmean and TWAmax. In conclusion, the excretion of 6-sulphatoxymelatonin retained a typical diurnal pattern under fast-rotating extended shifts and radiofrequency EMR, but showed an exposure-effect relation with stress hormones.

  11. Carbon Nanotube Field Emitters Synthesized on Metal Alloy Substrate by PECVD for Customized Compact Field Emission Devices to Be Used in X-Ray Source Applications.

    PubMed

    Park, Sangjun; Gupta, Amar Prasad; Yeo, Seung Jun; Jung, Jaeik; Paik, Sang Hyun; Mativenga, Mallory; Kim, Seung Hoon; Shin, Ji Hoon; Ahn, Jeung Sun; Ryu, Jehwang

    2018-05-29

    In this study, a simple, efficient, and economical process is reported for the direct synthesis of carbon nanotube (CNT) field emitters on metal alloy. Given that CNT field emitters can be customized with ease for compact and cold field emission devices, they are promising replacements for thermionic emitters in widely accessible X-ray source electron guns. High performance CNT emitter samples were prepared in optimized plasma conditions through the plasma-enhanced chemical vapor deposition (PECVD) process and subsequently characterized by using a scanning electron microscope, tunneling electron microscope, and Raman spectroscopy. For the cathode current, field emission (FE) characteristics with respective turn on (1 μA/cm²) and threshold (1 mA/cm²) field of 2.84 and 4.05 V/μm were obtained. For a field of 5.24 V/μm, maximum current density of 7 mA/cm² was achieved and a field enhancement factor β of 2838 was calculated. In addition, the CNT emitters sustained a current density of 6.7 mA/cm² for 420 min under a field of 5.2 V/μm, confirming good operational stability. Finally, an X-ray generated image of an integrated circuit was taken using the compact field emission device developed herein.

  12. Microscopic analysis of structural changes in diode-laser-welded corneal stroma

    NASA Astrophysics Data System (ADS)

    Matteini, Paolo; Rossi, Francesca; Menabuoni, Luca; Pini, Roberto

    2007-02-01

    Diode laser welding of the cornea is a technique used to provide immediate sealing of corneal wounds: the cut is stained with a water solution of Indocyanine Green and is then irradiated with an 810 nm laser at low power densities (12-16 W/cm2), which induces a localized heating of the stroma in the range 55-66 °C range. In this study, we present a microscopic analysis aimed at evaluating the structural modifications induced in the stromal collagen of pig eyes during the laser welding of corneal wounds. Cornea samples obtained from twenty freshly-enucleated eyes were cut with a pre-calibrated knife and subjected to the laser welding procedure. Histological slices of the laser-welded stroma were examined by means of optical and transmission electron microscopy. These analyses indicated that bridges of lamellar structures crossed the wound edges with no presence of a coagulation effect. After laser welding, collagen fibrils appeared differently oriented among themselves in comparison with those of the control samples, but with similar mean fibril diameters. The laser-induced effect appeared to be confined to the ICG stained area of the cut walls, and no heat damage was observed at the operative power levels of laser corneal welding.

  13. O5.05FLUORESCEIN-GUIDED REMOVAL OF HIGH-GRADE GLIOMAS WITH A DEDICATED FILTER ON THE SURGICAL MICROSCOPE: PRELIMINARY RESULTS OF THE FLUOGLIO STUDY

    PubMed Central

    Acerbi, F.; Broggi, M.; Cavallo, C.; Anghileri, E.; Eoli, M.; Schiariti, M.; Corte, E. La; Pollo, B.; Boffano, C.; Ferroli, P.

    2014-01-01

    BACKGROUND: Fluorescein is a fluorescent tracer that can be used for many applications. It is able to accumulate in brain areas with blood-brain barrier disruption, and thus it can be considered an ideal dye for intraoperative visualization of high-grade gliomas (HGG). We report the preliminary results of a phase II trail (FLUOGLIO) on a new fluorescein-guided technique to remove HHG with a dedicated filter on the surgical microscope. METHODS: In September 2011 we started a prospective phase II-trial (FLUOGLIO) to evaluated safety and obtain initial indications about efficacy of fluorescein-guided surgery for HGG. Patients with suspected HGG amenable to complete resection of contrast-enhancing area were eligible to participate in this study. This report is based on the analysis of the short- and long-term results in 28 consecutive patients with HGG (age range 45-74 years), enrolled since September 2011. Fluorescein was intravenous (i.v.) injected after intubation (5-10 mg/Kg). Tumor was removed with microsurgical technique and fluorescence visualization by BLU400 or YELLOW560 filters on Pentero microscope (Carl Zeiss, Germany). The study was approved by our Ethical Committee and registered on the European Regulatory Authorities website (EudraCT No. 2011-002527-18). RESULTS: Median pre-operative tumor volume was 33.1 cm3 (2.4-87.8 cm3). We found no adverse reaction to fluorescein administration. Tumor was completely removed in 80% of the patients. Median follow-up was 10 months. 6 months Progression-free Survival (PFS) and median survival were respectively 71.4 % and 11 months. CONCLUSION: Our analysis suggested that fluorescein-guided technique with a dedicated filter on the surgical microscope is safe and allows high-rate of complete resection of contrast-enhanced tumor at the early post-operative MRI.

  14. Disease Extent at Secondary Cytoreductive Surgery is Predictive of Progression-free and Overall Survival in Advanced Stage Ovarian Cancer: an NRG Oncology/Gynecologic Oncology Group study

    PubMed Central

    Rose, Peter G.; Java, James J.; Morgan, Mark A.; Secord, Angeles Alvarez; Kesterson, Joshua P.; Stehman, Frederick B.; Warshal, David P.; Creasman, William T.; Hanjani, Parviz; Morris, Robert T.; Copeland, Larry J.

    2017-01-01

    Purpose GOG 152 was a randomized trial of secondary cytoreductive surgery (SCS) in patients with suboptimal residual disease (residual tumor nodule >1 cm in greatest diameter) following primary cytoreductive surgery for advanced stage ovarian cancer. The current analysis was undertaken to evaluate the impact of disease findings at SCS on progression-free survival (PFS) and overall survival (OS). Methods Among the 550 patients enrolled on GOG-152, two-hundred-sixteen patients were randomly assigned following 3 cycles of cisplatin and paclitaxel to receive SCS. In 15 patients (7%) surgery was declined or contraindicated. In the remaining 201 patients the operative and pathology reports were utilized to classify their disease status at the beginning of SCS as; no gross disease/microscopically negative N= 40 (19.9%), no gross disease/microscopically positive N= 8 (4.0%), and gross disease N=153 (76.1%). Results The median PFS for patients with no gross disease/microscopically negative was 16.1 months, no gross disease/microscopically positive was 13.5 months and for gross disease was 11.7 months, p=0.002. The median OS for patients with no gross disease/microscopically negative was 51.5 months, no gross disease/microscopically positive was 42.6 months and for gross disease was 34.9 months, p=0.018. Conclusion Although as previously reported SCS did not change PFS or OS, for those who underwent the procedure, their operative and pathologic findings were predictive of PFS and OS. Surgical/pathological residual disease is a biomarker of response to chemotherapy and predictive of PFS and OS. PMID:27692669

  15. Technology development for phosphoric acid fuel cell powerplant, phase 2

    NASA Technical Reports Server (NTRS)

    Christner, L.

    1981-01-01

    The development of materials, cell components, and reformers for on site integrated energy systems is described. Progress includes: (1) heat-treatment of 25 sq cm, 350 sq cm and 1200 sq cm cell test hardware was accomplished. Performance of fuel cells is improved by using this material; (2) electrochemical and chemical corrosion rates of heat-treated and as-molded graphite/phenolic resin composites in phosphoric acid were determined; (3) three cell, 5 in. x 15 in. stacks operated for up to 10,000 hours and 12 in. x 17 in. five cell stacks were tested for 5,000 hours; (4) a three cell 5 in. x 15 in. stack with 0.12 mg Pt/sq cm anodes and 0.25 mg Pt/sq cm cathodes was operated for 4,500 hours; and (5) an ERC proprietary high bubble pressure matrix, MAT-1, was tested for up to 10,000 hours.

  16. Time-resolved fluorescence imaging of slab gels for lifetime base-calling in DNA sequencing applications.

    PubMed

    Lassiter, S J; Stryjewski, W; Legendre, B L; Erdmann, R; Wahl, M; Wurm, J; Peterson, R; Middendorf, L; Soper, S A

    2000-11-01

    A compact time-resolved near-IR fluorescence imager was constructed to obtain lifetime and intensity images of DNA sequencing slab gels. The scanner consisted of a microscope body with f/1.2 relay optics onto which was mounted a pulsed diode laser (repetition rate 80 MHz, lasing wavelength 680 nm, average power 5 mW), filtering optics, and a large photoactive area (diameter 500 microns) single-photon avalanche diode that was actively quenched to provide a large dynamic operating range. The time-resolved data were processed using electronics configured in a conventional time-correlated single-photon-counting format with all of the counting hardware situated on a PC card resident on the computer bus. The microscope head produced a timing response of 450 ps (fwhm) in a scanning mode, allowing the measurement of subnano-second lifetimes. The time-resolved microscope head was placed in an automated DNA sequencer and translated across a 21-cm-wide gel plate in approximately 6 s (scan rate 3.5 cm/s) with an accumulation time per pixel of 10 ms. The sampling frequency was 0.17 Hz (duty cycle 0.0017), sufficient to prevent signal aliasing during the electrophoresis separation. Software (written in Visual Basic) allowed acquisition of both the intensity image and lifetime analysis of DNA bands migrating through the gel in real time. Using a dual-labeling (IRD700 and Cy5.5 labeling dyes)/two-lane sequencing strategy, we successfully read 670 bases of a control M13mp18 ssDNA template using lifetime identification. Comparison of the reconstructed sequence with the known sequence of the phage indicated the number of miscalls was only 2, producing an error rate of approximately 0.3% (identification accuracy 99.7%). The lifetimes were calculated using maximum likelihood estimators and allowed on-line determinations with high precision, even when short integration times were used to construct the decay profiles. Comparison of the lifetime base calling to a single-dye/four-lane sequencing strategy indicated similar results in terms of miscalls, but reduced insertion and deletion errors using lifetime identification methods, improving the overall read accuracy.

  17. A mini-microscope for in situ monitoring of cells.

    PubMed

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R; Hamilton, Geraldine A; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E; Khademhosseini, Ali

    2012-10-21

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost.

  18. A mini-microscope for in situ monitoring of cells†‡

    PubMed Central

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R.; Hamilton, Geraldine A.; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E.

    2013-01-01

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost. PMID:22911426

  19. Compact very low temperature scanning tunneling microscope with mechanically driven horizontal linear positioning stage.

    PubMed

    Suderow, H; Guillamon, I; Vieira, S

    2011-03-01

    We describe a scanning tunneling microscope for operation in a dilution refrigerator with a sample stage which can be moved macroscopically in a range up to a cm and with an accuracy down to the tens of nm. The position of the tip over the sample as set at room temperature does not change more than a few micrometers when cooling down. This feature is particularly interesting for work on micrometer sized samples. Nanostructures can be also localized and studied, provided they are repeated over micrometer sized areas. The same stage can be used to approach a hard single crystalline sample to a knife and cleave it, or break it, in situ. In situ positioning is demonstrated with measurements at 0.1 K in nanofabricated samples. Atomic resolution down to 0.1 K and in magnetic fields of 8 T is demonstrated in NbSe(2). No heat dissipation nor an increase in mechanical noise has been observed at 0.1 K when operating the slider.

  20. Microscope sterility during spine surgery.

    PubMed

    Bible, Jesse E; O'Neill, Kevin R; Crosby, Colin G; Schoenecker, Jonathan G; McGirt, Matthew J; Devin, Clinton J

    2012-04-01

    Prospective study. Assess the contamination rates of sterile microscope drapes after spine surgery. The use of the operating microscope has become more prevalent in certain spine procedures, providing superior magnification, visualization, and illumination of the operative field. However, it may represent an additional source of bacterial contamination and increase the risk of developing a postoperative infection. This study included 25 surgical spine cases performed by a single spine surgeon that required the use of the operative microscope. Sterile culture swabs were used to obtain samples from 7 defined locations on the microscope drape after its use during the operation. The undraped technician's console was sampled in each case as a positive control, and an additional 25 microscope drapes were swabbed immediately after they were applied to the microscope to obtain negative controls. Swab samples were assessed for bacterial growth on 5% sheep blood Columbia agar plates using a semiquantitative technique. No growth was observed on any of the 25 negative control drapes. In contrast, 100% of preoperative and 96% of postoperative positive controls demonstrated obvious contamination. In the postoperative group, all 7 sites of evaluation were found to be contaminated with rates of 12% to 44%. Four of the 7 evaluated locations were found to have significant contamination rates compared with negative controls, including the shafts of the optic eyepieces on the main surgeon side (24%, P = 0.022), "forehead" portion on both the main surgeon (24%, P = 0.022) and assistant sides (28%, P = 0.010), and "overhead" portion of the drape (44%, P = 0.0002). Bacterial contamination of the operative microscope was found to be significant after spine surgery. Contamination was more common around the optic eyepieces, likely due to inadvertent touching of unsterile portions. Similarly, all regions above the eyepieces also have a propensity for contamination because of unknown contact with unsterile parts of the surgeon. Therefore, we believe that changing gloves after making adjustments to the optic eyepieces and avoid handling any portion of the drape above the eyepieces may decrease the risks of intraoperative contamination and possibly postoperative infection as well.

  1. Fabrication of high quality Cu2SnS3 thin film solar cell with 1.12% power conversion efficiency obtain by low cost environment friendly sol-gel technique

    NASA Astrophysics Data System (ADS)

    Chaudhari, J. J.; Joshi, U. S.

    2018-03-01

    Cu2SnS3 (CTS) is an emerging ternery chalcogenide material with great potential application in thin film solar cells. We present here high quality Cu2SnS3 thin films using a facile spin coating method. The as deposited films of CTS were sulphurized in a graphite box using tubular furnace at 520 °C for 60 min at the rate of 2.83 °C min-1 in argon atmosphere. X-ray diffraction (XRD) and Raman spectroscopy studies confirm tetragonal phase and absence of any secondary phase in sulphurized CTS thin films. X-ray photoelectron spectroscopy (XPS) demonstrates that Cu and Sn are in +1 and +4 oxidation state respectively. Surface morphology of CTS films were analyzed by field emission scanning electron microscope and atomic force microscope (AFM), which revealed a smooth surface with roughness (RMS) of 6.32 nm for sulphurized CTS film. Hall measurements confirmed p-type conductivity with hole concentartion of sulphurized CTS thin film is of 6.5348 × 1020 cm-3. UV-vis spectra revealed a direct energy band gap varies from 1.45 eV to 1.01 eV for as-deposited and sulphurized CTS thin film respectively. Such band gap values are optimum for semiconductor material as an absorber layer of thin film solar cell. The CTS thin film solar cell had following structure: SLG/FTO/ZnO/CTS/Al with short circuit current density of (Jsc) of 11.6 mA cm-2, open circuit voltage (Voc) of 0.276 V, active area of 0.16 cm2, fill factor (FF) of 35% and power conversion efficiency of 1.12% under AM 1.5 (100 mW cm-2) illumination in simulated standard test conditions.

  2. Low-voltage electron microscopy of polymer and organic molecular thin films.

    PubMed

    Drummy, Lawrence F; Yang, Junyan; Martin, David C

    2004-06-01

    We have demonstrated the capabilities of a novel low-voltage electron microscope (LVEM) for imaging polymer and organic molecular thin films. The LVEM can operate in transmission electron microscopy, scanning transmission electron microscopy, scanning electron microscopy, and electron diffraction modes. The microscope operates at a nominal accelerating voltage of 5 kV and fits on a tabletop. A detailed discussion of the electron-sample interaction processes is presented, and the mean free path for total electron scattering was calculated to be 15 nm for organic samples at 5 kV. The total end point dose for the destruction of crystallinity at 5 kV was estimated at 5 x 10(-4) and 3.5 x 10(-2) C/cm2 for polyethylene and pentacene, respectively. These values are significantly lower than those measured at voltages greater than 100 kV. A defocus series of colloidal gold particles allowed us to estimate the experimental contrast transfer function of the microscope. Images taken of several organic materials have shown high contrast for low atomic number elements and a resolution of 2.5 nm. The materials studied here include thin films of the organic semiconductor pentacene, triblock copolymer films, single-molecule dendrimers, electrospun polymer fibers and gold nanoparticles. Copyright 2004 Elsevier B.V.

  3. Ultrafine Particle Distribution and Chemical Composition Assessment during Military Operative Trainings

    PubMed Central

    Campagna, Marcello; Pilia, Ilaria; Marcias, Gabriele; Frattolillo, Andrea; Pili, Sergio; Bernabei, Manuele; d’Aloja, Ernesto; Cocco, Pierluigi; Buonanno, Giorgio

    2017-01-01

    (1) Background: The assessment of airborne particulate matter (PM) and ultrafine particles (UFPs) in battlefield scenarios is a topic of particular concern; (2) Methods: Size distribution, concentration, and chemical composition of UFPs during operative military training activities (target drone launches, ammunition blasting, and inert bomb impact) were investigated using an electric low-pressure impactor (ELPI+) and a scanning electron microscope (SEM), equipped with energy-dispersive spectroscopy (EDS); (3) Results: The median of UFPs, measured for all sampling periods and at variable distance from sources, was between 1.02 × 103 and 3.75 × 103 particles/cm3 for drone launches, between 3.32 × 103 and 15.4 × 103 particles/cm3 for the ammunition blasting and from 7.9 × 103 to 1.3 × 104 particles/cm3 for inert launches. Maximum peak concentrations, during emitting sources starting, were 75.5 × 106 and 17.9 × 106 particles/cm3, respectively. Particles from the drone launches were predominantly composed of silicon (Si), iron (Fe) and calcium (Ca), and those from the blasting campaigns by magnesium (Mg), sulphur (S), aluminum (Al), iron (Fe), barium (Ba) and silicon (Si); (4) Conclusions: The investigated sources produced UFPs with median values lower than other anthropogenic sources, and with a similar chemical composition. PMID:28556812

  4. High temperature superconductor dc SQUID micro-susceptometer for room temperature objects

    NASA Astrophysics Data System (ADS)

    Faley, M. I.; Pratt, K.; Reineman, R.; Schurig, D.; Gott, S.; Atwood, C. G.; Sarwinski, R. E.; Paulson, D. N.; Starr, T. N.; Fagaly, R. L.

    2004-05-01

    We have developed a scanning magnetic microscope (SMM) with 25 µm resolution in spatial position for the magnetic features of room temperature objects. The microscope consists of a high-temperature superconductor (HTS) dc SQUID sensor, suspended in vacuum with a self-adjusting standoff, close spaced liquid nitrogen Dewar, X-Y scanning stage and a computer control system. The HTS SQUIDs were optimized for better spatial and field resolutions for operation at liquid nitrogen temperature. Measured inside a magnetic shield, the 10 pT Hz-1/2 typical noise of the SQUIDs is white down to frequencies of about 10 Hz, increasing up to about 20 pT Hz-1/2 at 1 Hz. The microscope is mounted on actively damped platforms, which negate vibrations from the environment as well as damping internal stepper motor noises. A high-resolution video telescope and a 1 µm precision z-axis positioning system allow a close positioning of the sample under the sensor. The ability of the sensors to operate in unshielded environmental conditions with magnetic fields up to about 15 G allowed us to perform 2D mapping of the local ac and dc susceptibility of the objects.

  5. Synthesis of nanoscale copper nitride thin film and modification of the surface under high electronic excitation.

    PubMed

    Ghosh, S; Tripathi, A; Ganesan, V; Avasthi, D K

    2008-05-01

    Nanoscale (approximately 90 nm) Copper nitride (Cu3N) films are deposited on borosilicate glass and Si substrates by RF sputtering technique in the reactive environment of nitrogen gas. These films are irradiated with 200 MeV Au15+ ions from Pelletron accelerator in order to modify the surface by high electronic energy deposition of heavy ions. Due to irradiation (i) at incident ion fluence of 1 x 10(12) ions/cm2 enhancement of grains, (ii) at 5 x 10912) ions/cm2 mass transport on the films surface, (iii) at 2 x 10(13) ions/cm2 line-like features on Cu3N/glass and nanometallic structures on Cu3N/Si surface are observed. The surface morphology is examined by atomic force microscope (AFM). All results are explained on the basis of a thermal spike model of ion-solid interaction.

  6. Sedimentological Investigations of the Martian Surface using the Mars 2001 Robotic Arm Camera and MECA Optical Microscope

    NASA Technical Reports Server (NTRS)

    Rice, J. W., Jr.; Smith, P. H.; Marshall, J. R.

    1999-01-01

    The first microscopic sedimentological studies of the Martian surface will commence with the landing of the Mars Polar Lander (MPL) December 3, 1999. The Robotic Arm Camera (RAC) has a resolution of 25 um/p which will permit detailed micromorphological analysis of surface and subsurface materials. The Robotic Ann will be able to dig up to 50 cm below the surface. The walls of the trench will also be inspected by RAC to look for evidence of stratigraphic and / or sedimentological relationships. The 2001 Mars Lander will build upon and expand the sedimentological research begun by the RAC on MPL. This will be accomplished by: (1) Macroscopic (dm to cm): Descent Imager, Pancam, RAC; (2) Microscopic (mm to um RAC, MECA Optical Microscope (Figure 2), AFM This paper will focus on investigations that can be conducted by the RAC and MECA Optical Microscope.

  7. Room temperature operation of InxGa1-xSb/InAs type-II quantum well infrared photodetectors grown by MOCVD

    NASA Astrophysics Data System (ADS)

    Wu, D. H.; Zhang, Y. Y.; Razeghi, M.

    2018-03-01

    We demonstrate room temperature operation of In0.5Ga0.5Sb/InAs type-II quantum well photodetectors on an InAs substrate grown by metal-organic chemical vapor deposition. At 300 K, the detector exhibits a dark current density of 0.12 A/cm2 and a peak responsivity of 0.72 A/W corresponding to a quantum efficiency of 23.3%, with the calculated specific detectivity of 2.4 × 109 cm Hz1/2/W at 3.81 μm.

  8. Assessing various Infrared (IR) microscopic imaging techniques for post-mortem interval evaluation of human skeletal remains.

    PubMed

    Woess, Claudia; Unterberger, Seraphin Hubert; Roider, Clemens; Ritsch-Marte, Monika; Pemberger, Nadin; Cemper-Kiesslich, Jan; Hatzer-Grubwieser, Petra; Parson, Walther; Pallua, Johannes Dominikus

    2017-01-01

    Due to the influence of many environmental processes, a precise determination of the post-mortem interval (PMI) of skeletal remains is known to be very complicated. Although methods for the investigation of the PMI exist, there still remains much room for improvement. In this study the applicability of infrared (IR) microscopic imaging techniques such as reflection-, ATR- and Raman- microscopic imaging for the estimation of the PMI of human skeletal remains was tested. PMI specific features were identified and visualized by overlaying IR imaging data with morphological tissue structures obtained using light microscopy to differentiate between forensic and archaeological bone samples. ATR and reflection spectra revealed that a more prominent peak at 1042 cm-1 (an indicator for bone mineralization) was observable in archeological bone material when compared with forensic samples. Moreover, in the case of the archaeological bone material, a reduction in the levels of phospholipids, proteins, nucleic acid sugars, complex carbohydrates as well as amorphous or fully hydrated sugars was detectable at (reciprocal wavelengths/energies) between 3000 cm-1 to 2800 cm-1. Raman spectra illustrated a similar picture with less ν2PO43-at 450 cm-1 and ν4PO43- from 590 cm-1 to 584 cm-1, amide III at 1272 cm-1 and protein CH2 deformation at 1446 cm-1 in archeological bone material/samples/sources. A semi-quantitative determination of various distributions of biomolecules by chemi-maps of reflection- and ATR- methods revealed that there were less carbohydrates and complex carbohydrates as well as amorphous or fully hydrated sugars in archaeological samples compared with forensic bone samples. Raman- microscopic imaging data showed a reduction in B-type carbonate and protein α-helices after a PMI of 3 years. The calculated mineral content ratio and the organic to mineral ratio displayed that the mineral content ratio increases, while the organic to mineral ratio decreases with time. Cluster-analyses of data from Raman microscopic imaging reconstructed histo-anatomical features in comparison to the light microscopic image and finally, by application of principal component analyses (PCA), it was possible to see a clear distinction between forensic and archaeological bone samples. Hence, the spectral characterization of inorganic and organic compounds by the afore mentioned techniques, followed by analyses such as multivariate imaging analysis (MIAs) and principal component analyses (PCA), appear to be suitable for the post mortem interval (PMI) estimation of human skeletal remains.

  9. Assessing various Infrared (IR) microscopic imaging techniques for post-mortem interval evaluation of human skeletal remains

    PubMed Central

    Roider, Clemens; Ritsch-Marte, Monika; Pemberger, Nadin; Cemper-Kiesslich, Jan; Hatzer-Grubwieser, Petra; Parson, Walther; Pallua, Johannes Dominikus

    2017-01-01

    Due to the influence of many environmental processes, a precise determination of the post-mortem interval (PMI) of skeletal remains is known to be very complicated. Although methods for the investigation of the PMI exist, there still remains much room for improvement. In this study the applicability of infrared (IR) microscopic imaging techniques such as reflection-, ATR- and Raman- microscopic imaging for the estimation of the PMI of human skeletal remains was tested. PMI specific features were identified and visualized by overlaying IR imaging data with morphological tissue structures obtained using light microscopy to differentiate between forensic and archaeological bone samples. ATR and reflection spectra revealed that a more prominent peak at 1042 cm-1 (an indicator for bone mineralization) was observable in archeological bone material when compared with forensic samples. Moreover, in the case of the archaeological bone material, a reduction in the levels of phospholipids, proteins, nucleic acid sugars, complex carbohydrates as well as amorphous or fully hydrated sugars was detectable at (reciprocal wavelengths/energies) between 3000 cm-1 to 2800 cm-1. Raman spectra illustrated a similar picture with less ν2PO43−at 450 cm-1 and ν4PO43− from 590 cm-1 to 584 cm-1, amide III at 1272 cm-1 and protein CH2 deformation at 1446 cm-1 in archeological bone material/samples/sources. A semi-quantitative determination of various distributions of biomolecules by chemi-maps of reflection- and ATR- methods revealed that there were less carbohydrates and complex carbohydrates as well as amorphous or fully hydrated sugars in archaeological samples compared with forensic bone samples. Raman- microscopic imaging data showed a reduction in B-type carbonate and protein α-helices after a PMI of 3 years. The calculated mineral content ratio and the organic to mineral ratio displayed that the mineral content ratio increases, while the organic to mineral ratio decreases with time. Cluster-analyses of data from Raman microscopic imaging reconstructed histo-anatomical features in comparison to the light microscopic image and finally, by application of principal component analyses (PCA), it was possible to see a clear distinction between forensic and archaeological bone samples. Hence, the spectral characterization of inorganic and organic compounds by the afore mentioned techniques, followed by analyses such as multivariate imaging analysis (MIAs) and principal component analyses (PCA), appear to be suitable for the post mortem interval (PMI) estimation of human skeletal remains. PMID:28334006

  10. Multimodal Broadband Vibrational Sum Frequency Generation (MM-BB-V-SFG) Spectrometer and Microscope.

    PubMed

    Lee, Christopher M; Kafle, Kabindra; Huang, Shixin; Kim, Seong H

    2016-01-14

    A broadband sum frequency generation (BB-SFG) spectrometer with multimodal (MM) capabilities was constructed, which could be routinely reconfigured for tabletop experiments in reflection, transmission, and total internal reflection (TIR) geometries, as well as microscopic imaging. The system was constructed using a Ti:sapphire amplifier (800 nm, pulse width = 85 fs, repetition rate = 2 kHz), an optical parameter amplification (OPA) system for production of broadband IR pulses tunable between 1000 and 4000 cm(-1), and two Fabry-Pérot etalons arranged in series for production of narrowband 800 nm pulses. The key feature allowing the MM operation was the nearly collinear alignment of the visible (fixed, 800 nm) and infrared (tunable, 1000-4000 cm(-1)) pulses which were spatially separated. Physical insights discussed in this paper include the comparison of spectral bandwidth produced with 40 and 85 fs pump beams, the improvement of spectral resolution using etalons, the SFG probe volume in bulk analysis, the normalization of SFG signals, the stitching of multiple spectral segments, and the operation in different modes for air/liquid and adsorbate/solid interfaces, bulk samples, as well as spectral imaging combined with principle component analysis (PCA). The SFG spectral features obtained with the MM-BB-SFG system were compared with those obtained with picosecond-scanning-SFG system and high-resolution BB-SFG system (HR-BB-SFG) for dimethyl sulfoxide, α-pinene, and various samples containing cellulose (purified commercial products, Cladophora cell wall, cotton and flax fibers, and onion epidermis cell wall).

  11. Light-sheet microscopy for slide-free non-destructive pathology of large clinical specimens

    PubMed Central

    Glaser, Adam K.; Reder, Nicholas P.; Chen, Ye; McCarty, Erin F.; Yin, Chengbo; Wei, Linpeng; Wang, Yu; True, Lawrence D.; Liu, Jonathan T.C.

    2017-01-01

    For the 1.7 million patients per year in the U.S. who receive a new cancer diagnosis, treatment decisions are largely made after a histopathology exam. Unfortunately, the gold standard of slide-based microscopic pathology suffers from high inter-observer variability and limited prognostic value due to sampling limitations and the inability to visualize tissue structures and molecular targets in their native 3D context. Here, we show that an open-top light-sheet microscope optimized for non-destructive slide-free pathology of clinical specimens enables the rapid imaging of intact tissues at high resolution over large 2D and 3D fields of view, with the same level of detail as traditional pathology. We demonstrate the utility of this technology for various applications: wide-area surface microscopy to triage surgical specimens (with ~200 μm surface irregularities), rapid intraoperative assessment of tumour-margin surfaces (12.5 sec/cm2), and volumetric assessment of optically cleared core–needle biopsies (1 mm in diameter, 2 cm in length). Light-sheet microscopy can be a versatile tool for both rapid surface microscopy and deep volumetric microscopy of human specimens. PMID:29750130

  12. Use of an operating microscope during spine surgery is associated with minor increases in operating room times and no increased risk of infection

    PubMed Central

    Basques, Bryce A.; Golinvaux, Nicholas S.; Bohl, Daniel D.; Yacob, Alem; Toy, Jason O.; Varthi, Arya G.; Grauer, Jonathan N.

    2014-01-01

    Study Design Retrospective database review. Objective To evaluate whether microscope use during spine procedures is associated with increased operating room times or increased risk of infection. Summary of Background Data Operating microscopes are commonly used in spine procedures. It is debated whether the use of an operating microscope increases operating room time or confers increased risk of infection. Methods The American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database, which includes data from over 370 participating hospitals, was used to identify patients undergoing elective spinal procedures with and without an operating microscope for the years 2011 and 2012. Bivariate and multivariate linear regressions were used to test the association between microscope use and operating room times. Bivariate and multivariate logistic regressions were similarly conducted to test the association between microscope use and infection occurrence within 30 days of surgery. Results A total of 23,670 elective spine procedures were identified, of which 2,226 (9.4%) used an operating microscope. The average patient age was 55.1 ± 14.4 years. The average operative time (incision to closure) was 125.7 ± 82.0 minutes. Microscope use was associated with minor increases in preoperative room time (+2.9 minutes, p=0.013), operative time (+13.2 minutes, p<0.001), and total room time (+18.6 minutes, p<0.001) on multivariate analysis. A total of 328 (1.4%) patients had an infection within 30 days of surgery. Multivariate analysis revealed no significant difference between the microscope and non-microscope groups for occurrence of any infection, superficial surgical site infection (SSI), deep SSI, organ space infection, or sepsis/septic shock, regardless of surgery type. Conclusions We did not find operating room times or infection risk to be significant deterrents for use of an operating microscope during spine surgery. PMID:25188600

  13. [Longitudinal preputial pedicled flap urethroplasty for chordee of Donnahoo type IV].

    PubMed

    Zeng, Li; Shan, Wei; Yuan, Miao; Huang, Guizhen; Huang, Lugang

    2012-11-01

    To investigate the effectiveness of longitudinal preputial pedicled flap urethroplasty for chordee of Donnahoo IV type. Between June 1994 and October 2011, 30 patients with chordee (Donnahoo type IV) underwent longitudinal preputial pedicled flap urethroplasty. The patients' age ranged from 2 to 16 years (mean, 5.8 years). The morphology of the balanus-navicular fossa-external urethral orifice ranged normal; the penis length was 2.5-6.8 cm (mean, 4.3 cm); the penis bending angle was 35-70 degrees (mean, 40.1 degrees). Primary and secondary operation was 27 cases and 3 cases, respectively. The size of flap ranged from 1.5 cm x 1.3 cm to 4.0 cm x 2.0 cm. After correction, the penis length was 3.0-8.5 cm (mean, 6.6 cm); the penis bending angle was 0-10 degrees (mean, 1.2 degrees). All patients were followed up 6 months to 12 years (mean, 33 months). No recurrence, stabbing pain of the balanus, or foreign body sensation occurred during follow-up. Of them, 4 patients (13.33%) had urinary fistular, they had satisfactory results after the second operation; 2 patients (6.67%) had urethral stricture 1 month after operation, they also had satisfactory results after arethral dilatation. The other patients showed no scattering urinary flow and good direction without complication. Six patients had satisfactory sexual function after puberty without erection disorder, pain, or dyspareunia. Longitudinal preputial pedicled flap urethroplasty can achieve maximum utilization of prepuce and aesthetic and functional improvement with less complication, so it is a relatively ideal mean for treating chordee of Donnahoo type IV.

  14. A modular, open-source, slide-scanning microscope for diagnostic applications in resource-constrained settings

    PubMed Central

    Lu, Qiang; Liu, Guanghui; Xiao, Chuanli; Hu, Chuanzhen; Zhang, Shiwu; Xu, Ronald X.; Chu, Kaiqin; Xu, Qianming

    2018-01-01

    In this paper we report the development of a cost-effective, modular, open source, and fully automated slide-scanning microscope, composed entirely of easily available off-the-shelf parts, and capable of bright field and fluorescence modes. The automated X-Y stage is composed of two low-cost micrometer stages coupled to stepper motors operated in open-loop mode. The microscope is composed of a low-cost CMOS sensor and low-cost board lenses placed in a 4f configuration. The system has approximately 1 micron resolution, limited by the f/# of available board lenses. The microscope is compact, measuring just 25×25×30 cm, and has an absolute positioning accuracy of ±1 μm in the X and Y directions. A Z-stage enables autofocusing and imaging over large fields of view even on non-planar samples, and custom software enables automatic determination of sample boundaries and image mosaicking. We demonstrate the utility of our device through imaging of fluorescent- and transmission-dye stained blood and fecal smears containing human and animal parasites, as well as several prepared tissue samples. These results demonstrate image quality comparable to high-end commercial microscopes at a cost of less than US$400 for a bright-field system, with an extra US$100 needed for the fluorescence module. PMID:29543835

  15. Ultrafine Particle Distribution and Chemical Composition Assessment during Military Operative Trainings.

    PubMed

    Campagna, Marcello; Pilia, Ilaria; Marcias, Gabriele; Frattolillo, Andrea; Pili, Sergio; Bernabei, Manuele; d'Aloja, Ernesto; Cocco, Pierluigi; Buonanno, Giorgio

    2017-05-30

    (1) Background: The assessment of airborne particulate matter (PM) and ultrafine particles (UFPs) in battlefield scenarios is a topic of particular concern; (2) Methods: Size distribution, concentration, and chemical composition of UFPs during operative military training activities (target drone launches, ammunition blasting, and inert bomb impact) were investigated using an electric low-pressure impactor (ELPI+) and a scanning electron microscope (SEM), equipped with energy-dispersive spectroscopy (EDS); (3) Results: The median of UFPs, measured for all sampling periods and at variable distance from sources, was between 1.02 × 10³ and 3.75 × 10³ particles/cm³ for drone launches, between 3.32 × 10³ and 15.4 × 10³ particles/cm³ for the ammunition blasting and from 7.9 × 10³ to 1.3 × 10⁴ particles/cm³ for inert launches. Maximum peak concentrations, during emitting sources starting, were 75.5 × 10⁶ and 17.9 × 10⁶ particles/cm³, respectively. Particles from the drone launches were predominantly composed of silicon (Si), iron (Fe) and calcium (Ca), and those from the blasting campaigns by magnesium (Mg), sulphur (S), aluminum (Al), iron (Fe), barium (Ba) and silicon (Si); (4) Conclusions: The investigated sources produced UFPs with median values lower than other anthropogenic sources, and with a similar chemical composition.

  16. Developing a scalable inert gas ion thruster

    NASA Technical Reports Server (NTRS)

    James, E.; Ramsey, W.; Steiner, G.

    1982-01-01

    Analytical studies to identify and then design a high performance scalable ion thruster operating with either argon or xenon for use in large space systems are presented. The magnetoelectrostatic containment concept is selected for its efficient ion generation capabilities. The iterative nature of the bounding magnetic fields allows the designer to scale both the diameter and length, so that the thruster can be adapted to spacecraft growth over time. Three different thruster assemblies (conical, hexagonal and hemispherical) are evaluated for a 12 cm diameter thruster and performance mapping of the various thruster configurations shows that conical discharge chambers produce the most efficient discharge operation, achieving argon efficiencies of 50-80% mass utilization at 240-310 eV/ion and xenon efficiencies of 60-97% at 240-280 eV/ion. Preliminary testing of the large 30 cm thruster, using argon propellant, indicates a 35% improvement over the 12 cm thruster in mass utilization efficiency. Since initial performance is found to be better than projected, a larger 50 cm thruster is already in the development stage.

  17. Use of an operating microscope during spine surgery is associated with minor increases in operating room times and no increased risk of infection.

    PubMed

    Basques, Bryce A; Golinvaux, Nicholas S; Bohl, Daniel D; Yacob, Alem; Toy, Jason O; Varthi, Arya G; Grauer, Jonathan N

    2014-10-15

    Retrospective database review. To evaluate whether microscope use during spine procedures is associated with increased operating room times or increased risk of infection. Operating microscopes are commonly used in spine procedures. It is debated whether the use of an operating microscope increases operating room time or confers increased risk of infection. The American College of Surgeons National Surgical Quality Improvement Program database, which includes data from more than 370 participating hospitals, was used to identify patients undergoing elective spinal procedures with and without the use of an operating microscope for the years 2011 and 2012. Bivariate and multivariate linear regressions were used to test the association between microscope use and operating room times. Bivariate and multivariate logistic regressions were similarly conducted to test the association between microscope use and infection occurrence within 30 days of surgery. A total of 23,670 elective spine procedures were identified, of which 2226 (9.4%) used an operating microscope. The average patient age was 55.1±14.4 years. The average operative time (incision to closure) was 125.7±82.0 minutes.Microscope use was associated with minor increases in preoperative room time (+2.9 min, P=0.013), operative time (+13.2 min, P<0.001), and total room time (+18.6 min, P<0.001) on multivariate analysis.A total of 328 (1.4%) patients had an infection within 30 days of surgery. Multivariate analysis revealed no significant difference between the microscope and nonmicroscope groups for occurrence of any infection, superficial surgical site infection, deep surgical site infection, organ space infection, or sepsis/septic shock, regardless of surgery type. We did not find operating room times or infection risk to be significant deterrents for use of an operating microscope during spine surgery. 3.

  18. Unwarping confocal microscopy images of bee brains by nonrigid registration to a magnetic resonance microscopy image.

    PubMed

    Rohlfing, Torsten; Schaupp, Frank; Haddad, Daniel; Brandt, Robert; Haase, Axel; Menzel, Randolf; Maurer, Calvin R

    2005-01-01

    Confocal microscopy (CM) is a powerful image acquisition technique that is well established in many biological applications. It provides 3-D acquisition with high spatial resolution and can acquire several different channels of complementary image information. Due to the specimen extraction and preparation process, however, the shapes of imaged objects may differ considerably from their in vivo appearance. Magnetic resonance microscopy (MRM) is an evolving variant of magnetic resonance imaging, which achieves microscopic resolutions using a high magnetic field and strong magnetic gradients. Compared to CM imaging, MRM allows for in situ imaging and is virtually free of geometrical distortions. We propose to combine the advantages of both methods by unwarping CM images using a MRM reference image. Our method incorporates a sequence of image processing operators applied to the MRM image, followed by a two-stage intensity-based registration to compute a nonrigid coordinate transformation between the CM images and the MRM image. We present results obtained using CM images from the brains of 20 honey bees and a MRM image of an in situ bee brain. Copyright 2005 Society of Photo-Optical Instrumentation Engineers.

  19. Evaluation of a completely robotized neurosurgical operating microscope.

    PubMed

    Kantelhardt, Sven R; Finke, Markus; Schweikard, Achim; Giese, Alf

    2013-01-01

    Operating microscopes are essential for most neurosurgical procedures. Modern robot-assisted controls offer new possibilities, combining the advantages of conventional and automated systems. We evaluated the prototype of a completely robotized operating microscope with an integrated optical coherence tomography module. A standard operating microscope was fitted with motors and control instruments, with the manual control mode and balance preserved. In the robot mode, the microscope was steered by a remote control that could be fixed to a surgical instrument. External encoders and accelerometers tracked microscope movements. The microscope was additionally fitted with an optical coherence tomography-scanning module. The robotized microscope was tested on model systems. It could be freely positioned, without forcing the surgeon to take the hands from the instruments or avert the eyes from the oculars. Positioning error was about 1 mm, and vibration faded in 1 second. Tracking of microscope movements, combined with an autofocus function, allowed determination of the focus position within the 3-dimensional space. This constituted a second loop of navigation independent from conventional infrared reflector-based techniques. In the robot mode, automated optical coherence tomography scanning of large surface areas was feasible. The prototype of a robotized optical coherence tomography-integrated operating microscope combines the advantages of a conventional manually controlled operating microscope with a remote-controlled positioning aid and a self-navigating microscope system that performs automated positioning tasks such as surface scans. This demonstrates that, in the future, operating microscopes may be used to acquire intraoperative spatial data, volume changes, and structural data of brain or brain tumor tissue.

  20. Factor Structure of the Piagetian Stage of Concrete Operations.

    ERIC Educational Resources Information Center

    Klausmeier, Herbert J.; Sipple, Thomas S.

    1982-01-01

    The Piagetian developmental stage of concrete operational thought and the theoretical groupement structures underlying children's performance of 12 concrete operations tasks are discussed. Tasks were shown to develop in five related sets. Three factor structures were found in this longitudinal study. (Author/CM)

  1. Robotic autopositioning of the operating microscope.

    PubMed

    Oppenlander, Mark E; Chowdhry, Shakeel A; Merkl, Brandon; Hattendorf, Guido M; Nakaji, Peter; Spetzler, Robert F

    2014-06-01

    Use of the operating microscope has become pervasive since its introduction to the neurosurgical world. Neuronavigation fused with the operating microscope has allowed accurate correlation of the focal point of the microscope and its location on the downloaded imaging study. However, the robotic ability of the Pentero microscope has not been utilized to orient the angle of the microscope or to change its focal length to hone in on a predefined target. To report a novel technology that allows automatic positioning of the operating microscope onto a set target and utilization of a planned trajectory, either determined with the StealthStation S7 by using preoperative imaging or intraoperatively with the microscope. By utilizing the current motorized capabilities of the Zeiss OPMI Pentero microscope, a robotic autopositioning feature was developed in collaboration with Surgical Technologies, Medtronic, Inc. (StealthStation S7). The system is currently being tested at the Barrow Neurological Institute. Three options were developed for automatically positioning the microscope: AutoLock Current Point, Align Parallel to Plan, and Point to Plan Target. These options allow the microscope to pivot around the lesion, hover in a set plane parallel to the determined trajectory, or rotate and point to a set target point, respectively. Integration of automatic microscope positioning into the operative workflow has potential to increase operative efficacy and safety. This technology is best suited for precise trajectories and entry points into deep-seated lesions.

  2. Laser cleaning of ITER's diagnostic mirrors

    NASA Astrophysics Data System (ADS)

    Skinner, C. H.; Gentile, C. A.; Doerner, R.

    2012-10-01

    Practical methods to clean ITER's diagnostic mirrors and restore reflectivity will be critical to ITER's plasma operations. We report on laser cleaning of single crystal molybdenum mirrors coated with either carbon or beryllium films 150 - 420 nm thick. A 1.06 μm Nd laser system provided 220 ns pulses at 8 kHz with typical power densities of 1-2 J/cm^2. The laser beam was fiber optically coupled to a scanner suitable for tokamak applications. The efficacy of mirror cleaning was assessed with a new technique that combines microscopic imaging and reflectivity measurements [1]. The method is suitable for hazardous materials such as beryllium as the mirrors remain sealed in a vacuum chamber. Excellent restoration of reflectivity for the carbon coated Mo mirrors was observed after laser scanning under vacuum conditions. For the beryllium coated mirrors restoration of reflectivity has so far been incomplete and modeling indicates that a shorter duration laser pulse is needed. No damage of the molybdenum mirror substrates was observed.[4pt][1] C.H. Skinner et al., Rev. Sci. Instrum. at press.

  3. Mid-infrared study of stones from the Sutter's Mill meteorite

    NASA Astrophysics Data System (ADS)

    Nuevo, Michel; Sandford, Scott A.; Flynn, George J.; Wirick, Susan

    2014-11-01

    The Sutter's Mill meteorite fell in northern California on April 22, 2012. Several fragments of the meteorite were recovered, some of them shortly after the fall, others several days later after a heavy rainstorm. In this work, we analyzed several samples of four fragments―SM2, SM12, SM20, and SM30―from the Sutter's Mill meteorite with two infrared (IR) microscopes operating in the 4000-650 cm-1 (2.5-15.4 μm) range. Spectra show absorption features associated with minerals such as olivines, phyllosilicates, carbonates, and possibly pyroxenes, as well as organics. Spectra of specific minerals vary from one particle to another within a given stone, and even within a single particle, indicating a nonuniform mineral composition. Infrared features associated with aliphatic CH2 and CH3 groups associated with organics are also seen in several spectra. However, the presence of organics in the samples studied is not clear because these features overlap with carbonate overtone bands. Finally, other samples collected within days after the rainstorm show evidence for bacterial terrestrial contamination, which indicates how quickly meteorites can be contaminated on such small scales.

  4. SEM investigations of the cementum surface after irradiation with a frequency-doubled Alexandrite laser

    NASA Astrophysics Data System (ADS)

    Rechmann, Peter; Hennig, Thomas

    1996-04-01

    During prior studies it could be demonstrated while engaging a frequency doubled Alexandrite-laser (wavelength 380 nm, pulse duration 100 ns, fluence 1 J/cm2, pulse repetition rate 110 Hz) a fast and strictly selective ablation of supra- and subgingival calculus is possible. Even the removal of unstained microbial plaque was observed. First conclusions were drawn after light microscopical investigations on undecalcified sections of irradiated teeth. In the present study the cementum surface after irradiation with a frequency doubled Alexandrite-laser was observed by means of a Scanning Electron Microscope. After irradiation sections of teeth were dried in alcohol and sputtered with gold. In comparison irradiated cementum surfaces of unerupted operatively removed wisdom teeth and tooth surfaces after the selective removal of calculus were investigated. A complete removal of calculus was observed as well as a remaining smooth surface of irradiated cementum.

  5. Electrical conduction of organic ultrathin films evaluated by an independently driven double-tip scanning tunneling microscope.

    PubMed

    Takami, K; Tsuruta, S; Miyake, Y; Akai-Kasaya, M; Saito, A; Aono, M; Kuwahara, Y

    2011-11-02

    The electrical transport properties of organic thin films within the micrometer scale have been evaluated by a laboratory-built independently driven double-tip scanning tunneling microscope, operating under ambient conditions. The two tips were used as point contact electrodes, and current in the range from 0.1 pA to 100 nA flowing between the two tips through the material can be detected. We demonstrated two-dimensional contour mapping of the electrical resistance on a poly(3-octylthiophene) thin films as shown below. The obtained contour map clearly provided an image of two-dimensional electrical conductance between two point electrodes on the poly(3-octylthiophene) thin film. The conductivity of the thin film was estimated to be (1-8) × 10(-6) S cm(-1). Future prospects and the desired development of multiprobe STMs are also discussed.

  6. [Krukenberg ovary tumor pathological clinical study of 56 cases in the Instituto Nacional de Enfermedades Neoplasicas (National Cancer Institute)].

    PubMed

    Sánchez Lihón, Juvenal

    2009-01-01

    We report 56 cases of ovary Krukenberg tumor at Instituto Nacional de Enfermedades NeoplAsicas en relation to microscopic diagnosis, primary origin and clinicopathologic correlation. The patients ranged from 18 to 84 years. The most frecuent primary tumor was stomach 33 (58.9%) cases. Abdominal swelling and pain usually accounted for the clinical presentation. Ascitis, abnormal vaginal bleeding. 21 patients had frozen section.11(52.3%) cases the primary carcinoma was found during an operation for the ovary tumor and the most frecuent was stomach 9/21. 35 cases the tumor was bilateral the largest dimension was 30 x 20 cm microscopic examination showed variety of patterns.the survival data, follow up and prognosis is bad. It is important the correct diagnosis of Krukenberg tumor. We recommended frozen section. The prognosis is very poor.

  7. [Clinical effect of distally-based dorsal thumb neurocutaneous vascular flap on repair of soft tissue defect in thumb].

    PubMed

    Huang, Yixiong; Shen, Zunli; Wang, Yongchun; Zhang, Shimin

    2009-10-01

    To investigate the surgical methods and clinical results of repairing soft tissue defects in the thumb with distally-based dorsal thumb neurocutaneous vascular flap. From January 2006 to October 2007, 23 patients with soft tissue defect in the thumb were treated, including 20 males and 3 females aged 19-46 years old (average 27.5 years old). The defect was caused by crush injury in 1 case, electric planer accident in 6 cases, incised injury in 8 cases, and avulsion injury in 8 cases. The defect was located on the palmar aspect of the thumb distal phalanx in 3 cases, the dorsal-radial aspect of the thumb distal phalanx in 3 cases, and ulnar or dorsal aspect in 17 cases. The defect size ranged from 3.3 cm x 1.2 cm to 4.2 cm x 1.2 cm. Among them, 18 cases were complicated with distal 1/2 nail bed defect or injury. The time between injury and hospital admission was 1-72 hours (average 22 hours). During operation, the defect was repaired with distally-based dorsal-radial neurovenocutaneous vascular flap of the thumb in 3 cases and distally-based dorsal-ulnar neurovenocutaneous vascular flap of the thumb in 20 cases. The size of those flaps was 4.0 cm x 1.6 cm-5.0 cm x 3.0 cm. The donor site underwent direct suture or split thickness skin graft repair. At 10 days after operation, 3 cases suffered from the epidermal necrosis in the distal part of the flap, 2 of them experienced the exfoliation of dark scab 14 days later and the flap survived, and the flap of the rest one survived after dressing change. The other flaps and the skin graft at the donor site all survived uneventfully. The wounds healed by first intention. All the patients were followed up for 10-16 months (average 12.6 months). The flaps were soft in texture and full in appearance. The two-point discrimination value 6 months after operation was 8-10 mm. At 12 months after operation, the growth of the residual fingernail was evident in 18 cases, including 4 cases of curved or hook fingernail. Active flexion and extension of the thumb were normal. The abduction of the first web space reached or surpassed 80 percent of the normal side in 20 cases and was below 80 percent of the normal side in 3 cases. The clinical outcomes were satisfactory in 11 cases, approximately satisfactory in 8 cases, and unsatisfactory in 4 cases according to self-designed evaluation system. The operative method of repairing the soft tissue defects in the thumb with the distally-based dorsal thumb neurocutaneous vascular flap is simple, stable in anatomy, in line with the principle of proximity, and suitable for repairing thumb tip defect 3 cm in size. It can bring a good postoperative appearance of the thumb and little influence on the hand function.

  8. Structural Characterization and Gas Reactions of Small Metal Particles by High Resolution In-situ TEM and TED. [Transmission Electron Microscopy and Transmission Electron Diffraction

    NASA Technical Reports Server (NTRS)

    Heinemann, K.

    1985-01-01

    A commercial electron microscope with flat-plate upper pole piece configuration of the objective lens and top entry specimen introduction was modified to obtain 5 x 10 to the minus 10th power mbar pressure at the site of the specimen while maintaining the convenience of a specimen airlock system that allows operation in the 10 to the 10th power mbar range within 15 minutes after specimen change. The specimen chamber contains three wire evaporation sources, a specimen heater, and facilities for oxygen or hydrogen plasma treatment to clean as-introduced specimens. Evacuation is achieved by dural differential pumping, with fine entrance and exit apertures for the electron beam. With the microscope operating at .000001 mbar, the first differential pumping stage features a high-speed cryopump operating in a stainless steel chamber that can be mildly baked and reaches 1 x 10 to the minus 8th power mbar. The second stage, containing the evaporation sources and a custom ionization gauge within 10 cm from the specimen, is a rigorously uncompromised all-metal uhv-system that is bakable to above 200 C throughout and is pumped with an 80-liter ion pump. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) was achieved.

  9. Handheld White Light Interferometer for Measuring Defect Depth in Windows

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert; Simmons, Stephen; Cox, Robert

    2010-01-01

    Accurate quantification of defects (scratches and impacts) is vital to the certification of flight hardware and other critical components. The amount of damage to a particular component contributes to the performance, reliability, and safety of a system, which ultimately affects the success or failure of a mission or test. The launch-commit criteria on a Space Shuttle Orbiter window are governed by the depth of the defects that are identified by a visual inspection. This measurement of a defect is not easy to obtain given the environment, size of the defect, and location of the window(s). The determination of depth has typically been performed by taking a mold impression and measuring the impression with an optical profiling instrument. Another method of obtaining an estimate of the depth is by using a refocus microscope. To use a refocus microscope, the surface of the glass and bottom of the defect are, in turn, brought into focus by the operator. The amount of movement between the two points corresponds to the depth of the defect. The refocus microscope requires a skilled operator and has been proven to be unreliable when used on Orbiter windows. White light interferometry was chosen as a candidate to replace the refocus microscope. The White Light Interferometer (WLI) was developed to replace the refocus microscope as the instrument used for measuring the depth of defects in Orbiter windows. The WLI consists of a broadband illumination source, interferometer, detector, motion control, displacement sensor, mechanical housing, and support electronics. The illumination source for the WLI is typically a visible light emitting diode (LED) or a near-infrared superluminescent diode (SLD) with power levels of less than a milliwatt. The interferometer is a Michelson configuration consisting of a 1-in. (2.5-cm) cube beam splitter, a 0.5-in. (1.3-cm) optical window as a movable leg (used to closely match the return intensity of the fixed leg from the window), and a mirrored prism to fold the optics into the mechanical housing. The detector may be one of many C-mount CCD (charge-coupled device) cameras. Motion is provided by a commercial nanostepping motor with a serial interface. The displacement sensor is a custom device specifically designed for this application. The mechanical housing and support electronics were designed to integrate the various components into an instrument that could be physically handled by a technician and easily transported.

  10. Preparation and characterization of CdS/Si coaxial nanowires

    NASA Astrophysics Data System (ADS)

    Fu, X. L.; Li, L. H.; Tang, W. H.

    2006-04-01

    CdS/Si coaxial nanowires were fabricated via a simple one-step thermal evaporation of CdS powder in mass scale. Their crystallinities, general morphologies and detailed microstructures were characterized by using X-ray diffraction, scanning electron microscope, transmission electron microscope and Raman spectra. The CdS core crystallizes in a hexagonal wurtzite structure with lattice constants of a=0.4140 nm and c=0.6719 nm, and the Si shell is amorphous. Five Raman peaks from the CdS core were observed. They are 1LO at 305 cm -1, 2LO at 601 cm -1, A 1-TO at 212 cm -1, E 1-TO at 234 cm -1, and E 2 at 252 cm -1. Photoluminescence measurements show that the nanowires have two emission bands around 510 and 590 nm, which originate from the intrinsic transitions of CdS cores and the amorphous Si shells, respectively.

  11. Electric field induced cubic to monoclinic phase transition in multiferroic 0.65Bi(Ni{sub 1/2}Ti{sub 1/2})O{sub 3}-0.35PbTiO{sub 3} solid solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pandey, Rishikesh; Singh, Akhilesh Kumar, E-mail: akhilesh-bhu@yahoo.com

    2014-10-20

    The results of x-ray diffraction studies on 0.65Bi(Ni{sub 1/2}Ti{sub 1/2})O{sub 3}-0.35PbTiO{sub 3} solid solution poled at various electric fields are presented. After poling, significant value of planar electromechanical coupling coefficient (k{sub P}) is observed for this composition having cubic structure in unpoled state. The cubic structure of 0.65Bi(Ni{sub 1/2}Ti{sub 1/2})O{sub 3}-0.35PbTiO{sub 3} transforms to monoclinic structure with space group Pm for the poling field ≥5 kV/cm. Large c-axis microscopic lattice strain (1.6%) is achieved at 30 kV/cm poling field. The variation of the c-axis strain and unit cell volume with poling field shows a drastic jump similar to that observed for strainmore » versus electric field curve in (1 − x)Pb(Mg{sub 1/3}Nb{sub 2/3}) O{sub 3}-xPbTiO{sub 3} and (1 − x)Pb(Zn{sub 1/3}Nb{sub 2/3})O{sub 3}-xPbTiO{sub 3}.« less

  12. [The 80-th anniversary of the use of an operating microscope in otorhinolaryngology. Part II. Technical principle and operation of surgical microscope].

    PubMed

    Mroczkowski, Edward; Wielgosz, Romuald

    2004-01-01

    The first step to microsurgery is getting to know about technical principle and operation of the surgical microscopes. Special attention is paid to those modules and items of microscopes, which surgeon use most frequently, such as objectives, binocular tubes, eyepieces.

  13. Impact of affected lymph nodes on long-term outcome after surgical therapy of alveolar echinococcosis.

    PubMed

    Hillenbrand, Andreas; Beck, Annika; Kratzer, Wolfgang; Graeter, Tilmann; Barth, Thomas F E; Schmidberger, Julian; Möller, Peter; Henne-Bruns, Doris; Gruener, Beate

    2018-06-16

    Alveolar echinococcosis (AE) is a life-threatening helminthic disease. In humans, AE mostly affects the liver; the regional hepatic lymph nodes may be involved, indicating dissemination of AE from the liver. To achieve complete removal of the disease, enlarged hepatic lymph nodes may be resected during surgical treatment. We evaluated the frequency of affected lymph nodes by conventional microscopic and immunohistochemical analyses including detection of small particles of Echinococcus multilocularis (spem). Furthermore, we analyzed the association of resection of enlarged and affected lymph nodes with long-term outcome after surgical therapy of patients who underwent surgery with curative intent. We identified 43 patients who underwent hepatic surgery with curative intent with lymph node resection for AE. We analyzed the cohort for the manifestation of the parasite in the resected lymph nodes by conventional histology and by immunohistochemistry and compared these data with the further course of AE. Microscopically infected lymph nodes (laminar layer visible) were found in 7 out of these 43 patients (16%). In more than three quarters (25/32) of all specimens investigated, lymph nodes showed spems when stained with antibody against Em2G11, a monoclonal antibody specific for the Em2 antigen of the Echinococcus multilocularis metacestode. Most frequently, lymph nodes were resected due to enlargement. The median size of microscopically affected lymph nodes was 2 cm (range, 1.2 to 2.5 cm), the median size of immunohistochemically and non-affected lymph nodes was 1.3 cm each (range, "small" to 2.3 or 2.5 cm, respectively). Median follow-up was 8 years for all patients, 5 years for patients with lymph node resection, and 4 years for patients with infested lymph nodes. Overall, recurrent disease was seen in ten patients (10/109; 9%) after a median period of 1.5 years (range, 4 months to 4 years). None of the seven patients with conventionally microscopically affected lymph nodes suffered from recurrent disease. One patient with negative resected nodes and one patient with spems showed recurrent disease after 4 and 35 months, respectively. Lymph node involvement in AE is frequent, particularly when evaluated by immunohistochemical examination of lymph nodes with the monoclonal antibody Em2G11. Affected lymph nodes tend to be larger in size. Lymph node involvement is not associated with recurrent disease and therefore warrants further analysis of the biological significance of lymph node involvement.

  14. [The Development of First Operating Microscopes from Zeiss Jena and Oberkochen to Series Production].

    PubMed

    Gudziol, H; Gottschall, R; Luther, E

    2017-01-01

    Introduction: The history of the first operating microscopes from Zeiss is often confusing, not painstaking and partly contradictory because of the parallel development of Zeiss Jena (East Germany) and Zeiss Oberkochen (West Germany). Methods: To investigate the early beginnings of the construction of the operating microscopes documents of the Carl Zeiss Archive and the Optical Museum in Jena, the memoirs of Prof. Dr. Rosemarie Albrecht and some relevant publications were used. Results: The development of the first Jena operating microscope was initiated in 1949 by the ENT-physician Prof. Dr. Rosemarie Albrecht in the Soviet occupation zone. The first prototype was tested in the University ENT Clinic, Jena since summer of 1950. On the Leipzig Trade Fair in autumn 1952 the VEB Optik Carl Zeiss Jena presented the first operating microscope nationally and internationally. Series production began in 1953. The first operating microscope of Zeiss Oberkochen was primarily developed by technical designers (H. Littmann) as a colposcope. But in the Carl Zeiss Archive no documents could be found related to the cooperation with gynecologists. 1953 the operating microscope (OPMI 1) came into public and its series production started. From this date on, it was adopted by the otologist Prof. Dr. Horst Ludwig Wullstein to the needs of Otorhinolaryngology. Conclusion: The first Zeiss operating microscope came from Jena. The operating microscope from Zeiss Oberkochen had some advantages for the surgeons and won the competition in the future. © Georg Thieme Verlag KG Stuttgart · New York.

  15. In-Situ atomic force microscopic observation of ion beam bombarded plant cell envelopes

    NASA Astrophysics Data System (ADS)

    Sangyuenyongpipat, S.; Yu, L. D.; Brown, I. G.; Seprom, C.; Vilaithong, T.

    2007-04-01

    A program in ion beam bioengineering has been established at Chiang Mai University (CMU), Thailand, and ion beam induced transfer of plasmid DNA molecules into bacterial cells (Escherichia coli) has been demonstrated. However, a good understanding of the fundamental physical processes involved is lacking. In parallel work, onion skin cells have been bombarded with Ar+ ions at energy 25 keV and fluence1-2 × 1015 ions/cm2, revealing the formation of microcrater-like structures on the cell wall that could serve as channels for the transfer of large macromolecules into the cell interior. An in-situ atomic force microscope (AFM) system has been designed and installed in the CMU bio-implantation facility as a tool for the observation of these microcraters during ion beam bombardment. Here we describe some of the features of the in-situ AFM and outline some of the related work.

  16. Handheld nonlinear microscope system comprising a 2 MHz repetition rate, mode-locked Yb-fiber laser for in vivo biomedical imaging

    PubMed Central

    Krolopp, Ádám; Csákányi, Attila; Haluszka, Dóra; Csáti, Dániel; Vass, Lajos; Kolonics, Attila; Wikonkál, Norbert; Szipőcs, Róbert

    2016-01-01

    A novel, Yb-fiber laser based, handheld 2PEF/SHG microscope imaging system is introduced. It is suitable for in vivo imaging of murine skin at an average power level as low as 5 mW at 200 kHz sampling rate. Amplified and compressed laser pulses having a spectral bandwidth of 8 to 12 nm at around 1030 nm excite the biological samples at a ~1.89 MHz repetition rate, which explains how the high quality two-photon excitation fluorescence (2PEF) and second harmonic generation (SHG) images are obtained at the average power level of a laser pointer. The scanning, imaging and detection head, which comprises a conventional microscope objective for beam focusing, has a physical length of ~180 mm owing to the custom designed imaging telescope system between the laser scanner mirrors and the entrance aperture of the microscope objective. Operation of the all-fiber, all-normal dispersion Yb-fiber ring laser oscillator is electronically controlled by a two-channel polarization controller for Q-switching free mode-locked operation. The whole nonlinear microscope imaging system has the main advantages of the low price of the fs laser applied, fiber optics flexibility, a relatively small, light-weight scanning and detection head, and a very low risk of thermal or photochemical damage of the skin samples. PMID:27699118

  17. Handheld nonlinear microscope system comprising a 2 MHz repetition rate, mode-locked Yb-fiber laser for in vivo biomedical imaging.

    PubMed

    Krolopp, Ádám; Csákányi, Attila; Haluszka, Dóra; Csáti, Dániel; Vass, Lajos; Kolonics, Attila; Wikonkál, Norbert; Szipőcs, Róbert

    2016-09-01

    A novel, Yb-fiber laser based, handheld 2PEF/SHG microscope imaging system is introduced. It is suitable for in vivo imaging of murine skin at an average power level as low as 5 mW at 200 kHz sampling rate. Amplified and compressed laser pulses having a spectral bandwidth of 8 to 12 nm at around 1030 nm excite the biological samples at a ~1.89 MHz repetition rate, which explains how the high quality two-photon excitation fluorescence (2PEF) and second harmonic generation (SHG) images are obtained at the average power level of a laser pointer. The scanning, imaging and detection head, which comprises a conventional microscope objective for beam focusing, has a physical length of ~180 mm owing to the custom designed imaging telescope system between the laser scanner mirrors and the entrance aperture of the microscope objective. Operation of the all-fiber, all-normal dispersion Yb-fiber ring laser oscillator is electronically controlled by a two-channel polarization controller for Q-switching free mode-locked operation. The whole nonlinear microscope imaging system has the main advantages of the low price of the fs laser applied, fiber optics flexibility, a relatively small, light-weight scanning and detection head, and a very low risk of thermal or photochemical damage of the skin samples.

  18. Concordance of gross surgical and final fixed margins in vulvar intraepithelial neoplasia 3 and vulvar cancer.

    PubMed

    DeSimone, Christopher P; Crisp, Meredith P; Ueland, Frederick R; DePriest, Paul D; van Nagell, John R; Lele, Subodh M; Modesitt, Susan C

    2006-08-01

    To prospectively evaluate the concordance of initial surgical vulvar margins and final fixed margins and to determine the amount of microscopic pathology of grossly negative margins in women with vulvar intraepithelial neoplasia (VIN) 3 or vulvar carcinoma. Women with VIN 3 or vulvar carcinoma undergoing surgical excision were identified. Prior to excision, acetic acid was used to highlight the lesions, and 2 sutures were placed, 1 at the edge of gross disease and another 1 cm distal from the first. After specimen removal and fixation, the distance between sutures and microscopic involvement of VIN was determined. Twenty-seven women were enrolled; however, only 19 had final fixed specimens that could be accurately measured. The median fixed distance of the vulvar margin was 0.85 cm (mean, 0.83; SD, 0.19) as compared to the gross, 1-cm margin (p = 0.001). Three subjects (16%) had microscopic involvement by VIN 3 in the grossly negative epithelium between the 2 sutures, but none had a positive peripheral margin. The gross surgical margin after vulvar resection is reduced by 15% when measured in its final fixed state, and a grossly negative 1-cm margin will seldom harbor significant disease.

  19. Operation Urgent Fury - Grenada

    DTIC Science & Technology

    1983-11-01

    Urgent Fury : the planning and execution of joint operations in Grenada, 12 October-2 November 1983 / Ronald H. Cole. p . cm...meeting, Secretary of State George P . Shultz and the Chairman of the Joint Chiefs of Staff, General John W. Vessey, Jr., USA, warned the Special Situation...Group (RIG) of the National Security Council (NSC), on 12 October, Langhorne A. Motley, Assistant Secretary of State for Inter-American Affairs

  20. A frameless stereotaxic operating microscope for neurosurgery.

    PubMed

    Friets, E M; Strohbehn, J W; Hatch, J F; Roberts, D W

    1989-06-01

    A new system, which we call the frameless stereotaxic operating microscope, is discussed. Its purpose is to display CT or other image data in the operating microscope in the correct scale, orientation, and position without the use of a stereotaxic frame. A nonimaging ultrasonic rangefinder allows the position of the operating microscope and the position of the patient to be determined. Discrete fiducial points on the patient's external anatomy are located in both image space and operating room space, linking the image data and the operating room. Physician-selected image information, e.g., tumor contours or guidance to predetermined targets, is projected through the optics of the operating microscope using a miniature cathode ray tube and a beam splitter. Projected images superpose the surgical field, reconstructed from image data to match the focal plane of the operating microscope. The algorithms on which the system is based are described, and the sources and effects of errors are discussed. The system's performance is simulated, providing an estimate of accuracy. Two phantoms are used to measure accuracy experimentally. Clinical results and observations are given.

  1. Design, assembly, and testing of a high-resolution relay lens used for holography with operation at both doubled and tripled Nd:YAG laser wavelengths

    NASA Astrophysics Data System (ADS)

    Malone, Robert M.; Capelle, Gene A.; Cox, Brian C.; Frogget, Brent C.; Grover, Mike; Kaufman, Morris I.; Pazuchanics, Peter; Sorenson, Danny S.; Stevens, Gerald D.; Tibbitts, Aric; Turley, William D.

    2009-08-01

    The design and assembly of a nine-element lens that achieves >2000 lp/mm resolution at a 355-nm wavelength (ultraviolet) has been completed. By adding a doublet to this lens system, operation at a 532-nm wavelength (green) with >1100 lp/mm resolution is achieved. This lens is used with high-power laser light to record holograms of fast-moving ejecta particles from a shocked metal surface located inside a test package. Part of the lens and the entire test package are under vacuum with a 1-cm air gap separation. Holograms have been recorded with both doubled and tripled Nd:YAG laser light. The UV operation is very sensitive to the package window's tilt. If this window is tilted by more than 0.1 degrees, the green operation performs with better resolution than that of the UV operation. The setup and alignment are performed with green light, but the dynamic recording can be done with either UV light or green light. A resolution plate can be temporarily placed inside the test package so that a television microscope located beyond the hologram position can archive images of resolution patterns that prove that the calibration wires, interference filter, holographic plate, and relay lenses are in their correct positions. Part of this lens is under vacuum, at the point where the laser illumination passes through a focus. Alignment and tolerancing of this high-resolution lens are presented. Resolution variation across the 12-mm field of view and throughout the 5-mm depth of field is discussed for both wavelengths.

  2. Automated micromanipulation desktop station based on mobile piezoelectric microrobots

    NASA Astrophysics Data System (ADS)

    Fatikow, Sergej

    1996-12-01

    One of the main problems of present-day research on microsystem technology (MST) is to assemble a whole micro- system from different microcomponents. This paper presents a new concept of an automated micromanipulation desktop- station including piezoelectrically driven microrobots placed on a high-precise x-y-stage of a light microscope, a CCD-camera as a local sensor subsystem, a laser sensor unit as a global sensor subsystem, a parallel computer system with C167 microcontrollers, and a Pentium PC equipped additionally with an optical grabber. The microrobots can perform high-precise manipulations (with an accuracy of up to 10 nm) and a nondestructive transport (at a speed of about 3 cm/sec) of very small objects under the microscope. To control the desktop-station automatically, an advanced control system that includes a task planning level and a real-time execution level is being developed. The main function of the task planning sub-system is to interpret the implicit action plan and to generate a sequence of explicit operations which are sent to the execution level of the control system. The main functions of the execution control level are the object recognition, image processing and feedback position control of the microrobot and the microscope stage.

  3. Study of the toughening mechanisms in bone and biomimetic hydroxyapatite materials using Raman microprobe spectroscopy.

    PubMed

    Pezzotti, Giuseppe; Sakakura, Seiji

    2003-05-01

    A Raman microprobe spectroscopy characterization of microscopic fracture mechanisms is presented for a natural hydroxyapatite material (cortical bovine femur) and two synthetic hydroxyapatite-based materials with biomimetic structures-a hydroxyapatite skeleton interpenetrated with a metallic (silver) or a polymeric (nylon-6) phase. In both the natural and synthetic materials, a conspicuous amount of toughening arose from a microscopic crack-bridging mechanism operated by elasto-plastic stretching of unbroken second-phase ligaments along the crack wake. This mechanism led to a rising R-curve behavior. An additional micromechanism, responsible for stress relaxation at the crack tip, was recognized in the natural bone material and was partly mimicked in the hydroxyapatite/silver composite. This crack-tip mechanism conspicuously enhanced the cortical bone material resistance to fracture initiation. A piezo-spectroscopic technique, based on a microprobe measurement of 980 cm(-1) Raman line of hydroxyapatite, enabled us to quantitatively assess in situ the microscopic stress fields developed during fracture both at the crack tip and along the crack wake. Using the Raman piezo-spectroscopy technique, toughening mechanisms were assessed quantitatively and rationally related to the macroscopic fracture characteristics of hydroxyapatite-based materials. Copyright 2003 Wiley Periodicals, Inc.

  4. Electron Microscopist | Center for Cancer Research

    Cancer.gov

    PROGRAM DESCRIPTION The Cancer Research Technology Program (CRTP) develops and implements emerging technology, cancer biology expertise and research capabilities to accomplish NCI research objectives. The CRTP is an outward-facing, multi-disciplinary hub purposed to enable the external cancer research community and provides dedicated support to NCI’s intramural Center for Cancer Research (CCR). The dedicated units provide electron microscopy, protein characterization, protein expression, optical microscopy and genetics. These research efforts are an integral part of CCR at the Frederick National Laboratory for Cancer Research (FNLCR). CRTP scientists also work collaboratively with intramural NCI investigators to provide research technologies and expertise. KEY ROLES/RESPONSIBILITIES - THIS POSITION IS CONTINGENT UPON FUNDING APPROVAL The Electron Microscopist will: Operate ultramicrotomes (Leica) and other instrumentation related to the preparation of embedded samples for EM (TEM and SEM) Operate TEM microscopes, (specifically Hitachi, FEI T20 and FEI T12) as well as SEM microscopes (Hitachi); task will include loading samples, screening, and performing data collection for a variety of samples: from cells to proteins Manage maintenance for the TEM and SEM microscopes Provide technical advice to investigators on sample preparation and data collection

  5. Operating microscopes: past, present, and future.

    PubMed

    Uluç, Kutluay; Kujoth, Gregory C; Başkaya, Mustafa K

    2009-09-01

    The operating microscope is a fixture of modern surgical facilities, and it is a critically important factor in the success of many of the most complex and difficult surgical interventions used in medicine today. The rise of this key surgical tool reflects advances in understanding the principles of optics and vision that have occurred over centuries. The development of reading spectacles in the late 13th century led to the construction of early compound microscopes in the 16th and 17th centuries by Lippershey, Janssen, Galileo, Hooke, and others. Perhaps surprisingly, Leeuwenhoek's simple microscopes of this era offered improved performance over his contemporaries' designs. The intervening years saw improvements that reduced the spherical and chromatic aberrations present in compound microscopes. By the late 19th century, Carl Zeiss and Ernst Abbe ushered the compound microscope into the beginnings of the modern era of commercial design and production. The introduction of the microscope into the operating room by Nylén in 1921 initiated a revolution in surgical practice that gained momentum throughout the 1950s with multiple refinements, the introduction of the Zeiss OPMI series, and Kurze's application of the microscope to neurosurgery in 1957. Many of the refinements of the last 50 years have greatly improved the handling and practical operation of the surgical microscope, considerations which are equally important to its optical performance. Today's sophisticated operating microscopes allow for advanced real-time angiographic and tumor imaging. In this paper the authors discuss what might be found in the operating rooms of tomorrow.

  6. Laser ablated hard coating for microtools

    DOEpatents

    McLean, W. II; Balooch, M.; Siekhaus, W.J.

    1998-05-05

    Wear-resistant coatings composed of laser ablated hard carbon films, are deposited by pulsed laser ablation using visible light, on instruments such as microscope tips and micro-surgical tools. Hard carbon, known as diamond-like carbon (DLC), films produced by pulsed laser ablation using visible light enhances the abrasion resistance, wear characteristics, and lifetimes of small tools or instruments, such as small, sharp silicon tips used in atomic probe microscopy without significantly affecting the sharpness or size of these devices. For example, a 10--20 nm layer of diamond-like carbon on a standard silicon atomic force microscope (AFM) tip, enables the useful operating life of the tip to be increased by at least twofold. Moreover, the low inherent friction coefficient of the DLC coating leads to higher resolution for AFM tips operating in the contact mode. 12 figs.

  7. Interference experiment with asymmetric double slit by using 1.2-MV field emission transmission electron microscope.

    PubMed

    Harada, Ken; Akashi, Tetsuya; Niitsu, Kodai; Shimada, Keiko; Ono, Yoshimasa A; Shindo, Daisuke; Shinada, Hiroyuki; Mori, Shigeo

    2018-01-17

    Advanced electron microscopy technologies have made it possible to perform precise double-slit interference experiments. We used a 1.2-MV field emission electron microscope providing coherent electron waves and a direct detection camera system enabling single-electron detections at a sub-second exposure time. We developed a method to perform the interference experiment by using an asymmetric double-slit fabricated by a focused ion beam instrument and by operating the microscope under a "pre-Fraunhofer" condition, different from the Fraunhofer condition of conventional double-slit experiments. Here, pre-Fraunhofer condition means that each single-slit observation was performed under the Fraunhofer condition, while the double-slit observations were performed under the Fresnel condition. The interference experiments with each single slit and with the asymmetric double slit were carried out under two different electron dose conditions: high-dose for calculation of electron probability distribution and low-dose for each single electron distribution. Finally, we exemplified the distribution of single electrons by color-coding according to the above three types of experiments as a composite image.

  8. Atmospheric Seeing and Transparency Robotic Observatory

    NASA Astrophysics Data System (ADS)

    Cline, J. D.; Castelaz, M. W.

    2002-12-01

    A robotic 12.7 cm telescope and camera (together called OVIEW) have been designed to do photometry of 50 of the brightest stars in the local sky 24 hours a day. Each star is imaged through a broadband 500 nm filter. Software automatically analyzes the brightness of the star and the stellar seeing disk. The results are published in real-time on a web page. Comparison of stellar brightness with known apparent magnitude is a measure of transparency with instrument resolution of one arcsecond. We will describe the observatory, software, and website. We will also describe other telescopes on the Optical Ridge at the Pisgah Astronomical Research Institute (PARI). On the same pier as OVIEW is a second robotic 12.7 cm telescope and camera that image the sun and moon. The solar and lunar images are published live on the Internet. Also on the Optical Ridge is a robotic 20 cm telescope. This telescope is operated by UNC-Chapel Hill and has been operating on the Optical Ridge for more than 2 years surveying the plane of the Milky Way for binary low mass stars. UNC-Chapel Hill also operates a 25 cm telescope with an IR camera for photometry of gamma ray burst optical afterglows. An additional 25 cm telescope with a new 3.2 megapixel CCD is used for undergraduate research and W UMa binary star photometry. We acknowledge the AAS Small Grant Program for partial support of the solar/lunar telescope.

  9. A Student-Built Scanning Tunneling Microscope

    ERIC Educational Resources Information Center

    Ekkens, Tom

    2015-01-01

    Many introductory and nanotechnology textbooks discuss the operation of various microscopes including atomic force (AFM), scanning tunneling (STM), and scanning electron microscopes (SEM). In a nanotechnology laboratory class, students frequently utilize microscopes to obtain data without a thought about the detailed operation of the tool itself.…

  10. Preventive and therapeutic effects of low level laser irradiation on gentamicin vestibulotoxicity in rat utricle

    NASA Astrophysics Data System (ADS)

    Rhee, Chung-Ku; Oh, Yang Hee; Ahn, Jin-Chul; Jung, Min-Sang; Kim, Yeong-Sik; Suh, Myung-Whan

    2009-02-01

    Purpose: To investigate the effects of low level laser (LLL) irradiation for the prevention and treatment of aminoglycoside-induced vestibular ototoxicity. Materials and Methods: An organotypic culture of 2 to 4 days old rat utricular maculae hair cells was used. The cultured utricular hair cells were divided into 6 groups. Group C: the hair cells were cultured for 14 days. Group G: cultured hair cells were treated with 1 mM gentamicin (GM) for 48 hours. Group L: LLL irradiation with 670 nm diode laser 3 mW/cm2 for 60 min (10.8 J/cm2)/day for 14 days. Group LG: LLL irradiation 10.8 J/ cm2/day for 2 days followed by GM insult. Group GL: treated with GM and followed by LLL irradiation 10.8 J/ cm2/day for 12 days. LGL group: LLL irradiation 10.8 J/ cm2/day for 2 days, then GM insulted, followed by the LLLT 10.8 J/ cm2/day for 10 days. The hair cells in each group were examined and counted by confocal laser scanning electron microscope on 7th and 14th days after FM1-43 staining and observed by scanning electron microscope (SEM). Results: The number of vestibular hair cells of group G was significantly less than those in group C. Group L showed no difference compared to group C. Significantly higher numbers of cells were seen in Group LG and GL comparing to group G. The cells were more in LG than group GL. Group LGL showed the most vestibular hair cells compared to the G, LG, and GL groups. SEM showed damaged hair cells in group G while they were well preserved in groups C, L, LG, GL, and LGL. Conclusion: LLL irradiation before and after GM insult on utricular hair cells were most effective to prevent and treat GM ototoxicity. This study indicates that LLL irradiation may have clinical implications to treat various vestibular and cochlear inner ear diseases.

  11. Ultrasound guided needle localization and microsurgical exploration for incidental nonpalpable testicular tumors.

    PubMed

    Hopps, Carin V; Goldstein, Marc

    2002-09-01

    We describe a technique by which incidental, nonpalpable intratesticular tumors are excised using intraoperative ultrasonography and the operating microscope. Men with impalpable intratesticular tumors incidentally detected by ultrasonography underwent intraoperative ultrasound guided needle localization and microsurgical exploration of the mass. The testis was delivered through an inguinal incision and placed on ice to minimize warm ischemia. Two rubber shod vascular clamps were placed across the spermatic cord. The tumor was identified by ultrasound and localized with a 30 gauge needle, which was placed adjacent to the tumor. An operating microscope providing 6x to 25x magnification was used to excise the lesion with a 2 to 5 mm. margin. Tissue diagnosis was obtained by frozen section. Multiple random biopsies of the remaining parenchyma were done to confirm absent malignancy. Ultrasound showed incidental, nonpalpable testis tumors in 4 of the 65 men who underwent infertility evaluation and were entered into the microsurgical testis biopsy database between January 1995 and December 2001. All lesions were hypoechoic. Frozen section analysis of the lesions revealed 2 Leydig cell tumors, 1 mass with an inconclusive pathological diagnosis and 1 inflammatory mass. On permanent section the latter 2 lesions were seminoma. The seminomas were 1.6 and 0.9 cm. in the greatest diameter, and the Leydig cell tumors were 0.35 and 0.2 cm., respectively. Random biopsies were positive for seminoma and intratubular germ cell neoplasia in both testes with seminoma. These 2 patients subsequently opted to undergo radical orchiectomy. No residual tumor was detected in either radical orchiectomy specimen. Intraoperative ultrasound guided needle localization with microsurgical exploration is a safe and effective approach to even small impalpable testicular masses. This technique provides the opportunity to identify and remove benign and malignant lesions, and preserve the testis when the lesion is benign. In cases of a solitary testis or bilateral synchronous lesions the technique allows a potentially testis sparing operation for small malignancies.

  12. The head-mounted microscope.

    PubMed

    Chen, Ting; Dailey, Seth H; Naze, Sawyer A; Jiang, Jack J

    2012-04-01

    Microsurgical equipment has greatly advanced since the inception of the microscope into the operating room. These advancements have allowed for superior surgical precision and better post-operative results. This study focuses on the use of the Leica HM500 head-mounted microscope for the operating phonosurgeon. The head-mounted microscope has an optical zoom from 2× to 9× and provides a working distance from 300 mm to 700 mm. The headpiece, with its articulated eyepieces, adjusts easily to head shape and circumference, and offers a focus function, which is either automatic or manually controlled. We performed five microlaryngoscopic operations utilizing the head-mounted microscope with successful results. By creating a more ergonomically favorable operating posture, a surgeon may be able to obtain greater precision and success in phonomicrosurgery. Phonomicrosurgery requires the precise manipulation of long-handled cantilevered instruments through the narrow bore of a laryngoscope. The head-mounted microscope shortens the working distance compared with a stand microscope, thereby increasing arm stability, which may improve surgical precision. Also, the head-mounted design permits flexibility in head position, enabling operator comfort, and delaying musculoskeletal fatigue. A head-mounted microscope decreases the working distance and provides better ergonomics in laryngoscopic microsurgery. These advances provide the potential to promote precision in phonomicrosurgery. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  13. Histology confirms that macroscopic evaluation of ovaries is a valid method for the assessment of the reproductive status in wild boar.

    PubMed

    Gethöffer, Friederike; Pfarrer, Christiane; Siebert, Ursula

    2018-06-01

    Research on reproduction and fertility is an essential fundament of management strategies in European wild boar. Concerning the examination of the reproductive tract, methods still lack conformity and comparability. So far the reproductive status of female wild boar has been assessed by ovarian macroscopic examination. In order to find out if this is a valid method, 21 ovaries of 8-34 months old animals covering (early) follicular phase and cyclic inactivity were evaluated microscopically. Number and dimension of follicles as well as the occurrence of atretic follicles were compared and related to age, weight, ovary weight and size of ovary. For this study, 21 ovaries of the right side of each animal were weighed and measured. The diameter of the functional bodies was measured and functional bodies were counted. Size of ovary was calculated by length*width*height (cm 3 ). Macroscopically, follicles were classified into four categories by diameter: F1 (0.2-0.3 cm), F2 (0.4-0.5 cm), F3 (0.6-0.8 cm) and F4 (0.9-1.3 cm). Microscopically, antral follicles of every 10th slice per section of each ovary were counted and classified into three categories by diameter: F0 (≥2 mm), FS (1-2 mm) and FXS (≤1 mm). In follicles with a diameter greater than 2 mm (F0), length and width were measured from the beginning of theca interna. Results showed that age and weight of wild boars were highly correlated (cor = 0.845, p < 0.001). Wild boar of higher age and weight showed higher ovary weight, but this was not significant (p = 0.135 (age), p = 0.329 (weight)). Although the number of macroscopically seen follicles differed widely by animal, microscopically only one ovary showed only small tertiary follicles. Animals with bigger follicles showed a significantly (p = 0.006) smaller number of small and smallest tertiary follicles. The number of tertiary follicles (F0) was not significantly influenced by age or carcass weight (p = 0.460, 0.159). Older and heavier animals showed significantly less FX and FXS (p < 0.001). Comparison of the follicular composition of young wild boar ovaries with domestic pig research allows the conclusion that assessment of cyclic activity and near puberty is possible. However, due to the fact that puberty is a long term biological progress, defining the time of sexual maturity will always be an estimate. Nevertheless, microscopic examination confirmed the macroscopic findings, including follicular dimensions and developmental stage allowing the conclusion that macroscopic evaluation of ovarian functional bodies in wild boar is an easy and reliable way to assess reproductive performance. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Compact Wireless Microscope for In-Situ Time Course Study of Large Scale Cell Dynamics within an Incubator

    NASA Astrophysics Data System (ADS)

    Jin, Di; Wong, Dennis; Li, Junxiang; Luo, Zhang; Guo, Yiran; Liu, Bifeng; Wu, Qiong; Ho, Chih-Ming; Fei, Peng

    2015-12-01

    Imaging of live cells in a region of interest is essential to life science research. Unlike the traditional way that mounts CO2 incubator onto a bulky microscope for observation, here we propose a wireless microscope (termed w-SCOPE) that is based on the “microscope-in-incubator” concept and can be easily housed into a standard CO2 incubator for prolonged on-site observation of the cells. The w-SCOPE is capable of tunable magnification, remote control and wireless image transmission. At the same time, it is compact, measuring only ~10 cm in each dimension, and cost-effective. With the enhancement of compressive sensing computation, the acquired images can achieve a wide field of view (FOV) of ~113 mm2 as well as a cellular resolution of ~3 μm, which enables various forms of follow-up image-based cell analysis. We performed 12 hours time-lapse study on paclitaxel-treated MCF-7 and HEK293T cell lines using w-SCOPE. The analytic results, such as the calculated viability and therapeutic window, from our device were validated by standard cell detection assays and imaging-based cytometer. In addition to those end-point detection methods, w-SCOPE further uncovered the time course of the cell’s response to the drug treatment over the whole period of drug exposure.

  15. Compact Wireless Microscope for In-Situ Time Course Study of Large Scale Cell Dynamics within an Incubator

    PubMed Central

    Jin, Di; Wong, Dennis; Li, Junxiang; Luo, Zhang; Guo, Yiran; Liu, Bifeng; Wu, Qiong; Ho, Chih-Ming; Fei, Peng

    2015-01-01

    Imaging of live cells in a region of interest is essential to life science research. Unlike the traditional way that mounts CO2 incubator onto a bulky microscope for observation, here we propose a wireless microscope (termed w-SCOPE) that is based on the “microscope-in-incubator” concept and can be easily housed into a standard CO2 incubator for prolonged on-site observation of the cells. The w-SCOPE is capable of tunable magnification, remote control and wireless image transmission. At the same time, it is compact, measuring only ~10 cm in each dimension, and cost-effective. With the enhancement of compressive sensing computation, the acquired images can achieve a wide field of view (FOV) of ~113 mm2 as well as a cellular resolution of ~3 μm, which enables various forms of follow-up image-based cell analysis. We performed 12 hours time-lapse study on paclitaxel-treated MCF-7 and HEK293T cell lines using w-SCOPE. The analytic results, such as the calculated viability and therapeutic window, from our device were validated by standard cell detection assays and imaging-based cytometer. In addition to those end-point detection methods, w-SCOPE further uncovered the time course of the cell’s response to the drug treatment over the whole period of drug exposure. PMID:26681552

  16. GFO-1 Geophysical Data Record and Orbit Verifications for Global Change Studies

    NASA Technical Reports Server (NTRS)

    Shum, C. K.

    2000-01-01

    This final report summarizes the research work conducted under NASA's Physical Oceanography Program, entitled, GFO-1 Geophysical Data Record And Orbit Verifications For Global Change Studies, for the investigation time period from December 1, 1997 through November 30, 2000. The primary objectives of the investigation include providing verification and improvement for the precise orbit, media, geophysical, and instrument corrections to accurately reduce U.S. Navy's Geosat-Followon-1 (GFO-1) mission radar altimeter data to sea level measurements. The status of the GFO satellite (instrument and spacecraft operations, orbital tracking and altimeter) is summarized. GFO spacecraft has been accepted by the Navy from Ball Aerospace and has been declared operational since November, 2000. We have participated in four official GFO calibration/validation periods (Cal/Val I-IV), spanning from June 1999 through October 2000. Results of verification of the GFO orbit and geophysical data record measurements both from NOAA (IGDR) and from the Navy (NGDR) are reported. Our preliminary results indicate that: (1) the precise orbit (GSFC and OSU) can be determined to approx. 5 - 6 cm rms radially using SLR and altimeter crossovers; (2) estimated GFO MOE (GSFC or NRL) radial orbit accuracy is approx. 7 - 30 cm and Operational Doppler orbit accuracy is approx. 60 - 350 cm. After bias and tilt adjustment (1000 km arc), estimated Doppler orbit accuracy is approx. 1.2 - 6.5 cm rms and the MOE accuracy is approx. 1.0 - 2.3 cm; (3) the geophysical and media corrections have been validated versus in situ measurements and measurements from other operating altimeters (T/P and ERS-2). Altimeter time bias is insignificant with 0-2 ms. Sea state bias is about approx. 3 - 4.5% of SWH. Wet troposphere correction has approx. 1 cm bias and approx. 3 cm rms when compared with ERS-2 data. Use of GIM and IRI95 provide ionosphere correction accurate to 2-3 cm rms during medium to high solar activities; (4) the noise of the GFO altimeter data (uncorrected SSH) is about 15 mm, compared to 19 min for ERS-2, and 12 min for TOPEX. It is anticipated that the operational GFO-1 altimeter data will contribute to a number of researches in physical oceanography. A list of relevant presentations and publications is attached.

  17. Nano-Welding of Multi-Walled Carbon Nanotubes on Silicon and Silica Surface by Laser Irradiation.

    PubMed

    Yuan, Yanping; Chen, Jimin

    2016-02-24

    In this study, a continuous fiber laser (1064 nm wavelength, 30 W/cm²) is used to irradiate multi-walled carbon nanotubes (MWCNTs) on different substrate surfaces. Effects of substrates on nano-welding of MWCNTs are investigated by scanning electron microscope (SEM). For MWCNTs on silica, after 3 s irradiation, nanoscale welding with good quality can be achieved due to breaking C-C bonds and formation of new graphene layers. While welding junctions can be formed until 10 s for the MWCNTs on silicon, the difference of irradiation time to achieve welding is attributed to the difference of thermal conductivity for silica and silicon. As the irradiation time is prolonged up to 12.5 s, most of the MWCNTs are welded to a silicon substrate, which leads to their frameworks of tube walls on the silicon surface. This is because the accumulation of absorbed energy makes the temperature rise. Then chemical reactions among silicon, carbon and nitrogen occur. New chemical bonds of Si-N and Si-C achieve the welding between the MWCNTs and silicon. Vibration modes of Si₃N₄ appear at peaks of 363 cm -1 and 663 cm -1 . There are vibration modes of SiC at peaks of 618 cm -1 , 779 cm -1 and 973 cm -1 . The experimental observation proves chemical reactions and the formation of Si₃N₄ and SiC by laser irradiation.

  18. InGaAs/GaAsSb Type-II superlattice based photodiodes for short wave infrared detection

    NASA Astrophysics Data System (ADS)

    Uliel, Y.; Cohen-Elias, D.; Sicron, N.; Grimberg, I.; Snapi, N.; Paltiel, Y.; Katz, M.

    2017-08-01

    Short Wave Infra-Red (SWIR) photodetectors operating above the response cutoff of InGaAs- based detectors (1.7-2.5 μm) are required for both defense and civil applications. Type II Super-Lattices (T2SL) were recently proposed For near- room temperature SWIR detection as a possible system enabling bandgap adjustment in the required range. The work presented here focuses on a T2SL with alternating nano-layers of InGaAs and GaAsSb lattice-matched to an InP substrate. A near room temperature SWIR cutoff of 2.4 μm was measured. Electrical junctions were realized using Zn diffusion p-doping process. We realized and studied both mesa- and selective diffusion- based p-i-n photodiodes. Dark currents of mesa-based devices were 1.5 mA/cm2 and 32 μA/cm2 at 300 and 230 K respectively. Dark currents were reduced to 1.2 mA/cm2 and 12 μA/cm2 respectively by utilizing the selective diffusion process. The effect of operating voltage is discussed. At 300 K the quantum efficiency was up to 40% at 2.18 μm in mesa devices. D∗ was 1.7 ×1010cm ·√{Hz } /W at 2 μm.

  19. [Testicular artery-sparing microscopic varicocelectomy combined with Qilin Pills for bilateral varicocele-induced oligoasthenospermia].

    PubMed

    Zhang, Hua-Feng; Zhao, Jia

    2016-10-01

    To explore the clinical effect of testicular artery-sparing microscopic varicocelectomy (MV) in combination with Qilin Pills (QL) in the treatment of bilateral varicocele-induced oligoasthenospermia. Sixty patients with bilateral varicocele-induced oligoasthenospermia were randomly assigned to receive MV (n=30) or MV+QL (n=30), those in the latter group treated with oral QL for 12 weeks postoperatively. At 4, 8, and 12 weeks after operation, we compared the semen volume, sperm concentration, sperm motility, the levels of serum Inh B, luteinizing hormone (LH) and total testosterone (TT), and the testosterone secretion index (TSI) between the two groups. After surgery, all the patients showed disappearance of varicocele symptoms, remarkably improved semen volume, sperm concentration, sperm motility, serum Inh B and TT levels, TSI, decreased LH and FSH (P<0.01). At 12 weeks after treatment, statistically significant differences were found between the MV and MV+QL groups in Inh B (138.96±22.26 vs 129.54±22.23) ng/L, LH (3.17±0.12 vs 3.59±0.11) IU/L, TT (13.98±3.02 vs 12.68±3.12) nmol/L, and TSI (4.41±0.53 vs 3.53±0.51) nmol/ IU (P<0.05). The pregnancy rate was significantly higher in the MV+QL than in the MV group (73.4% vs 36.6%, P<0.05). Testicular artery-sparing microscopic varicocelectomy combined with Qilin Pills is an effective strategy for the treatment of bilateral varicocele-induced oligoasthenospermia by significantly improving the semen quality of the patient.

  20. High-Rate Capable Floating Strip Micromegas

    NASA Astrophysics Data System (ADS)

    Bortfeldt, Jonathan; Bender, Michael; Biebel, Otmar; Danger, Helge; Flierl, Bernhard; Hertenberger, Ralf; Lösel, Philipp; Moll, Samuel; Parodi, Katia; Rinaldi, Ilaria; Ruschke, Alexander; Zibell, André

    2016-04-01

    We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in high-background environments and at very high particle fluxes up to 60 MHz/cm2. Measurement and simulation of the microscopic discharge behavior have demonstrated the excellent discharge tolerance. A floating strip Micromegas with an active area of 48 cm × 50 cm with 1920 copper anode strips exhibits in 120 GeV pion beams a spatial resolution of 50 μm at detection efficiencies above 95%. Pulse height, spatial resolution and detection efficiency are homogeneous over the detector. Reconstruction of particle track inclination in a single detector plane is discussed, optimum angular resolutions below 5° are observed. Systematic deviations of this μTPC-method are fully understood. The reconstruction capabilities for minimum ionizing muons are investigated in a 6.4 cm × 6.4 cm floating strip Micromegas under intense background irradiation of the whole active area with 20 MeV protons at a rate of 550 kHz. The spatial resolution for muons is not distorted by space charge effects. A 6.4 cm × 6.4 cm floating strip Micromegas doublet with low material budget is investigated in highly ionizing proton and carbon ion beams at particle rates between 2 MHz and 2 GHz. Stable operation up to the highest rates is observed, spatial resolution, detection efficiencies, the multi-hit and high-rate capability are discussed.

  1. An apparatus for studying electrical breakdown in liquid helium at 0.4 K and testing electrode materials for the neutron electric dipole moment experiment at the Spallation Neutron Source

    NASA Astrophysics Data System (ADS)

    Ito, T. M.; Ramsey, J. C.; Yao, W.; Beck, D. H.; Cianciolo, V.; Clayton, S. M.; Crawford, C.; Currie, S. A.; Filippone, B. W.; Griffith, W. C.; Makela, M.; Schmid, R.; Seidel, G. M.; Tang, Z.; Wagner, D.; Wei, W.; Williamson, S. E.

    2016-04-01

    We have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and ˜600 Torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of 1-2 cm between them, and a potential up to ±50 kV can be applied to each electrode. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes 12 cm in diameter for a wide range of pressures at 0.4 K. We also measured the current between two electrodes. Our initial results, I < 1 pA at 45 kV, correspond to a lower bound on the effective volume resistivity of liquid helium of ρV > 5 × 1018 Ω cm. This lower bound is 5 times larger than the bound previously measured. We report the design, construction, and operational experience of the apparatus, as well as initial results.

  2. An apparatus for studying electrical breakdown in liquid helium at 0.4 K and testing electrode materials for the neutron electric dipole moment experiment at the Spallation Neutron Source.

    PubMed

    Ito, T M; Ramsey, J C; Yao, W; Beck, D H; Cianciolo, V; Clayton, S M; Crawford, C; Currie, S A; Filippone, B W; Griffith, W C; Makela, M; Schmid, R; Seidel, G M; Tang, Z; Wagner, D; Wei, W; Williamson, S E

    2016-04-01

    We have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and ∼600 Torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of 1-2 cm between them, and a potential up to ±50 kV can be applied to each electrode. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes 12 cm in diameter for a wide range of pressures at 0.4 K. We also measured the current between two electrodes. Our initial results, I < 1 pA at 45 kV, correspond to a lower bound on the effective volume resistivity of liquid helium of ρV > 5 × 10(18) Ω cm. This lower bound is 5 times larger than the bound previously measured. We report the design, construction, and operational experience of the apparatus, as well as initial results.

  3. NASA Marshall Space Flight Center solar observatory report, January - June 1991

    NASA Technical Reports Server (NTRS)

    Smith, James E.

    1991-01-01

    Given here is a summary of the solar vector magnetic field, H-alpha, and white-light observations made at the NASA/Marshall Space Flight Center (MSFC) Solar Observatory during its daily periods of operation. The MSFC Solar Observatory facilities consist of the Solar Magnetograph, an f/13, 30-cm Cassegrain system with a 3.5-cm image of the Sun, housed on top of a 12.8-meter tower; a 12.5-cm Razdow H-alpha telescope housed at the base of the tower; an 18-cm Questar telescope with a full aperture white-light filter mounted at the base of the tower; a 30-cm Cassegrain telescope located in a second metal dome; and a 16.5-cm H-alpha telescope mounted on side of the Solar Vector Magnetograph. A concrete block building provides office space, a darkroom for developing film and performing optical testing, a workshop, video displays, and a computer facility for data reduction.

  4. Compact, light-weight and cost-effective microscope based on lensless incoherent holography for telemedicine applications.

    PubMed

    Mudanyali, Onur; Tseng, Derek; Oh, Chulwoo; Isikman, Serhan O; Sencan, Ikbal; Bishara, Waheb; Oztoprak, Cetin; Seo, Sungkyu; Khademhosseini, Bahar; Ozcan, Aydogan

    2010-06-07

    Despite the rapid progress in optical imaging, most of the advanced microscopy modalities still require complex and costly set-ups that unfortunately limit their use beyond well equipped laboratories. In the meantime, microscopy in resource-limited settings has requirements significantly different from those encountered in advanced laboratories, and such imaging devices should be cost-effective, compact, light-weight and appropriately accurate and simple to be usable by minimally trained personnel. Furthermore, these portable microscopes should ideally be digitally integrated as part of a telemedicine network that connects various mobile health-care providers to a central laboratory or hospital. Toward this end, here we demonstrate a lensless on-chip microscope weighing approximately 46 grams with dimensions smaller than 4.2 cm x 4.2 cm x 5.8 cm that achieves sub-cellular resolution over a large field of view of approximately 24 mm(2). This compact and light-weight microscope is based on digital in-line holography and does not need any lenses, bulky optical/mechanical components or coherent sources such as lasers. Instead, it utilizes a simple light-emitting-diode (LED) and a compact opto-electronic sensor-array to record lensless holograms of the objects, which then permits rapid digital reconstruction of regular transmission or differential interference contrast (DIC) images of the objects. Because this lensless incoherent holographic microscope has orders-of-magnitude improved light collection efficiency and is very robust to mechanical misalignments it may offer a cost-effective tool especially for telemedicine applications involving various global health problems in resource limited settings.

  5. Alignment-free, all-spliced fiber laser source for CARS microscopy based on four-wave-mixing.

    PubMed

    Baumgartl, Martin; Gottschall, Thomas; Abreu-Afonso, Javier; Díez, Antonio; Meyer, Tobias; Dietzek, Benjamin; Rothhardt, Manfred; Popp, Jürgen; Limpert, Jens; Tünnermann, Andreas

    2012-09-10

    An environmentally-stable low-repetition rate fiber oscillator is developed to produce narrow-bandwidth pulses with several tens of picoseconds duration. Based on this oscillator an alignment-free all-fiber laser for multi-photon microscopy is realized using in-fiber frequency conversion based on four-wave-mixing. Both pump and Stokes pulses for coherent anti-Stokes Raman scattering (CARS) microscopy are readily available from one fiber end, intrinsically overlapped in space and time, which drastically simplifies the experimental handling for the user. The complete laser setup is mounted on a home-built laser scanning microscope with small footprint. High-quality multimodal microscope images of biological tissue are presented probing the CH-stretching resonance of lipids at an anti-Stokes Raman-shift of 2845 cm(-1) and second-harmonic generation of collagen. Due to its simplicity, compactness, maintenance-free operation, and ease-of-use the presented low-cost laser is an ideal source for bio-medical applications outside laser laboratories and in particular inside clinics.

  6. Scalable patterning using laser-induced shock waves

    NASA Astrophysics Data System (ADS)

    Ilhom, Saidjafarzoda; Kholikov, Khomidkhodza; Li, Peizhen; Ottman, Claire; Sanford, Dylan; Thomas, Zachary; San, Omer; Karaca, Haluk E.; Er, Ali O.

    2018-04-01

    An advanced direct imprinting method with low cost, quick, and minimal environmental impact to create a thermally controllable surface pattern using the laser pulses is reported. Patterned microindents were generated on Ni50Ti50 shape memory alloys and aluminum using an Nd: YAG laser operating at 1064 nm combined with a suitable transparent overlay, a sacrificial layer of graphite, and copper grid. Laser pulses at different energy densities, which generate pressure pulses up to a few GPa on the surface, were focused through the confinement medium, ablating the copper grid to create plasma and transferring the grid pattern onto the surface. Scanning electron microscope and optical microscope images show that various patterns were obtained on the surface with high fidelity. One-dimensional profile analysis indicates that the depth of the patterned sample initially increases with the laser energy and later levels off. Our simulations of laser irradiation process also confirm that high temperature and high pressure could be generated when the laser energy density of 2 J/cm2 is used.

  7. Screening small-molecule compound microarrays for protein ligands without fluorescence labeling with a high-throughput scanning microscope.

    PubMed

    Fei, Yiyan; Landry, James P; Sun, Yungshin; Zhu, Xiangdong; Wang, Xiaobing; Luo, Juntao; Wu, Chun-Yi; Lam, Kit S

    2010-01-01

    We describe a high-throughput scanning optical microscope for detecting small-molecule compound microarrays on functionalized glass slides. It is based on measurements of oblique-incidence reflectivity difference and employs a combination of a y-scan galvometer mirror and an x-scan translation stage with an effective field of view of 2 cm x 4 cm. Such a field of view can accommodate a printed small-molecule compound microarray with as many as 10,000 to 20,000 targets. The scanning microscope is capable of measuring kinetics as well as endpoints of protein-ligand reactions simultaneously. We present the experimental results on solution-phase protein reactions with small-molecule compound microarrays synthesized from one-bead, one-compound combinatorial chemistry and immobilized on a streptavidin-functionalized glass slide.

  8. Screening small-molecule compound microarrays for protein ligands without fluorescence labeling with a high-throughput scanning microscope

    PubMed Central

    Fei, Yiyan; Landry, James P.; Sun, Yungshin; Zhu, Xiangdong; Wang, Xiaobing; Luo, Juntao; Wu, Chun-Yi; Lam, Kit S.

    2010-01-01

    We describe a high-throughput scanning optical microscope for detecting small-molecule compound microarrays on functionalized glass slides. It is based on measurements of oblique-incidence reflectivity difference and employs a combination of a y-scan galvometer mirror and an x-scan translation stage with an effective field of view of 2 cm×4 cm. Such a field of view can accommodate a printed small-molecule compound microarray with as many as 10,000 to 20,000 targets. The scanning microscope is capable of measuring kinetics as well as endpoints of protein-ligand reactions simultaneously. We present the experimental results on solution-phase protein reactions with small-molecule compound microarrays synthesized from one-bead, one-compound combinatorial chemistry and immobilized on a streptavidin-functionalized glass slide. PMID:20210464

  9. Influence of Noncompliance With Radiation Therapy Protocol Guidelines and Operative Bed Recurrences for Children With Rhabdomyosarcoma and Microscopic Residual Disease: A Report From the Children's Oncology Group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Million, Lynn, E-mail: lynn.million@hci.utah.ed; Anderson, James; Breneman, John

    2011-06-01

    Purpose: Postoperative radiation therapy (RT) is recommended for patients with rhabdomyosarcoma having microscopic disease. Sometimes RT dose/volume is reduced or omitted in an attempt to avoid late effects, particularly in young children. We reviewed operative bed recurrences to determine if noncompliance with RT protocol guidelines influenced local-regional control. Methods and Materials: All operative bed recurrences among 695 Group II rhabdomyosarcoma patients in Intergroup Rhabdomyosarcoma Study Group (IRS) I through IV were reviewed for deviation from RT protocol. Major/minor dose deviation was defined as >10% or 6-10% of the prescribed dose (40-60 Gy), respectively. Major/minor volume deviation was defined as tumormore » excluded from the RT field or treatment volume not covered by the specified margin (preoperative tumor volume and 2- to 5-cm margin), respectively. No RT was a major deviation. Results: Forty-six of 83 (55%) patients with operative bed recurrences did not receive the intended RT (39 major and 7 minor deviations). RT omission was the most frequent RT protocol deviation (19/46, 41%), followed by dose (17/46, 37%), volume (9/46, 20%), and dose and volume deviation (1/46, 2%). Only 7 operative bed recurrences occurred in IRS IV (5% local-regional failure) with only 3 RT protocol deviations. Sixty-three (76%) patients with recurrence died of disease despite retrieval therapy, including 13 of 19 nonirradiated children. Conclusion: Over half of the operative bed recurrences were associated with noncompliance; omission of RT was the most common protocol deviation. Three fourths of children die when local-regional disease is not controlled, emphasizing the importance of RT in Group II rhabdomyosarcoma.« less

  10. Higher operation temperature quadrant photon detectors of 2-11 μm wavelength radiation with large photosensitive areas

    NASA Astrophysics Data System (ADS)

    Pawluczyk, J.; Sosna, A.; Wojnowski, D.; Koźniewski, A.; Romanis, M.; Gawron, W.; Piotrowski, J.

    2017-10-01

    We report on the quadrant photon HgCdTe detectors optimized for 2-11 μm wavelength spectral range and Peltier or no cooling, and photosensitive area of a quad-cell of 1×1 to 4×4 mm. The devices are fabricated as photoconductors or multiple photovoltaic cells connected in series (PVM). The former are characterized by a relatively uniform photosensitive area. The PVM photovoltaic cells are distributed along the wafer surface, comprising a periodical stripe structure with a period of 20 μm. Within each period, there is an insensitive gap/trench < 9 μm wide between stripe mesas. The resulting spatial quantization error prevents positioning of the beam spot of size close to the period, but becomes negligible for the optimal spot size comparable to a quadrant-cell area. The photoconductors produce 1/f noise with about 10 kHz knee frequency, due to bias necessary for their operation. The PVM photodiodes are typically operated at 0 V bias, so they generate no 1/f noise and operation from DC is enabled. At 230 K, upper corner frequency of 16 to 100 MHz is obtained for photoconductor and 60 to 80 MHz for PVM, normalized detectivity D* 6×107 cm×Hz1/2/W to >1.4×108 cm×Hz1/2/W for photoconductor and >1.7×108 cm·Hz1/2/W for PVM, allowing for position control of the radiation beam with submicron accuracy at 16 MHz, 10.6 μm wavelength of pulsed radiation spot of 0.8 mm dia at the close-to-maximal input radiation power density in a range of detector linear operation.

  11. Analysis of the cause of failure in nonsurgical endodontic treatment by microscopic inspection during endodontic microsurgery.

    PubMed

    Song, Minju; Kim, Hyeon-Cheol; Lee, Woocheol; Kim, Euiseong

    2011-11-01

    This study examined the clinical causes of failure and the limitation of a previous endodontic treatment by an inspection of the root apex and resected root surface at 26× magnification during endodontic microsurgery. The data were collected from patients in the Department of Conservative Dentistry at the Dental College, Yonsei University in Seoul, Korea between March 2001 and January 2011. All root-filled cases with symptomatic or asymptomatic apical periodontitis were enrolled in this study. All surgical procedures were performed by using an operating microscope. The surface of the apical root to be resected or the resected root surface after methylene blue staining was examined during the surgical procedure and recorded carefully with 26× magnification to determine the state of the previous endodontic treatment by using an operating microscope. Among the 557 cases with periapical surgery, 493 teeth were included in this study. With the exclusion of unknown cases, the most common possible cause of failure was perceived leakage around the canal filling material (30.4%), followed by a missing canal (19.7%), underfilling (14.2%), anatomical complexity (8.7%), overfilling (3.0%), iatrogenic problems (2.8%), apical calculus (1.8%), and cracks (1.2%). The frequency of possible failure causes differed according to the tooth position (P < .001). An appreciation of the root canal anatomy by using an operating microscope in nonsurgical endodontic treatment can make the prognosis more predictable and favorable. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. [Primary testicular rhabdomyosarcoma: A case report].

    PubMed

    Mejía-Salas, Jesús Alberto; Sánchez-Corona, Hugo; Priego-Niño, Alejandro; Cárdenas-Rodríguez, Edgar; Sánchez-Galindo, José Antonio

    Rhabdomyosarcoma is the most common sarcoma of soft tissues in childhood and adolescence, with an annual incidence of 4-7 cases per million children aged 15. Embryonal rhabdomyosarcoma is common in adults younger than 30 years, and are usually presented as a large painless, palpable mass (> 5cm). Survival in the case of paratesticular sarcoma in men is approximately 50%. Male 27 years of age with no history of importance, was seen in a clinic with an increased, painless, left testicular volume 3 years onset. Intrascrotal left testicle increased volume, with dimensions of 20×12×8cm, a stone and left inguinal node in induratum measuring 2×2cm. Microscopically, it showed a pattern of an embryonal rhabdomyosarcoma with left inguinal node metastases. Early diagnosis of testicular tumours, and especially of primary intratesticular rhabdomyosarcomas, and aggressive surgical treatment in combination with chemotherapy reduces the incidence of local recurrence and may improve the rate of disease-free survival and overall survival in adult patients with metastases. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  13. Cosmic dust particle densities - Evidence for two populations of stony micrometeorites

    NASA Technical Reports Server (NTRS)

    Flynn, G. J.; Sutton, S. R.

    1991-01-01

    The existence of two populations of stony micrometeorites of distinctly different densities would result in significantly different orbital evolution properties for particles from each group. The densities inferred from deceleration of meteors in the earth's atmosphere suggest a substantial amount of the meteoric material has densities of 1 g/cu cm or less (Verniani, 1973). However, measurements of microcraters on lunar rock surfaces led Brownlee et al. (1973) to the conclusion that most micrometeoroids impacting the moon had densities in the 2-4 g/cu cm range, and low-density micrometeoroids were rare. The recovery of stony micrometeorites from the earth's stratosphere after atmospheric deceleration provides the opportunity to resolve the discrepancies. Here, the densities of 12 stony micrometeorites are determined, using synchrotron X-ray fluorescence to infer the particle mass and optical microscope measurements of the volumes. The particles fall into two distinct density groups, with mean values of 0.6 and 1.9 g/cu cm. The factor of 3 difference in the mean densities between the two populations implies differences in the orbital evolution time scales.

  14. An in-vitro animal experiment on metal implants’ thermal effect on radiofrequency ablation

    PubMed Central

    2013-01-01

    Background To explore metal implants’ thermal effect on radiofrequency ablation (RFA) and ascertain distance-thermal relationship between the metal implants and radiofrequency (RF) electrode. Methods Metal implants models were established in seven in-vitro porcine livers using silver clips or 125I seeds. RFA were conducted centering the RF electrode axis1 cm away from them, with one side containing a metal implants model the test group and the other side the control group. The thermometric needles were used to measure multi-point temperatures in order to compare the time-distance-temperature difference between the two groups. The gross scopes of the ablation of the two groups were measured and the tissues were analyzed for microscopic histology. Results At the ablation times of 8, 12, and 15 min, the average multi-point temperatures of the test group and the control group were 48.2±18.07°C, 51.5±19.57°C, 54.6±19.75°C, and 48.6±17.69°C, 52.2±19.73°C, 54.9±19.24°C, respectively, and the differences were not statistically significant (n=126, P>0.05). At the ablation times of 12 and 15 min, the ablation scopes of the test group and the control group were (horizontal/longitudinal diameter) 1.55/3.48 cm, 1.89/3.72 cm, and 1.56/3.48 cm, 1.89/3.72 cm, respectively, and the differences were not statistically significant (n=14, P>0.05). The two groups had the same manifestations in microscopy. Conclusions Metal implants do not cause significant thermal effect on RFA. PMID:23799942

  15. Auricular burns associated with operating microscope use during otologic surgery.

    PubMed

    Latuska, Richard F; Carlson, Matthew L; Neff, Brian A; Driscoll, Colin L; Wanna, George B; Haynes, David S

    2014-02-01

    To raise awareness of the potential hazard of auricular burns associated with operating microscope use during otologic surgery. Retrospective case series and summary of the Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience (MAUDE) database of voluntary adverse event reports pertaining to microscope related auricular thermal injuries. All patients who sustained auricular burns while using the operating microscope during otologic surgery at 2 tertiary academic referral centers. Surgical procedure, microscope model, intensity of illumination, length of procedure, focal length, location and severity of burn, and patient outcome. A total of 4 microscope-related auricular thermal injuries were identified from the authors' institutions. Additionally, 82 unique cases of soft tissue burns associated with the use of an operative microscope have been voluntarily reported to the FDA since 2004. A disproportionately large percent (∼ 30%) of these occurred within the field of otology, the majority of which were during tympanoplasty or tympanomastoidectomy procedures at focal length distances of 300 mm or less with xenon light source microscopes. Simultaneous advancements in light delivery technologies and lens optics have continued to improve the efficiency of the operating microscope; however, these improvements also increase the potential for thermal injuries. Although rare, a review of the FDA MAUDE database suggests that microscope-related soft tissue burns occur more frequently in otology than any other surgical specialty. A variety of factors may help explain this finding, including the unique anatomy of the external ear with thin skin and limited underlying adipose tissue. Preventative measures should be taken to decrease the risk of thermal injuries including use of the lowest comfortable light intensity, adjusting the aperture width to match the operative field, frequent wound irrigation, and covering exposed portions of the pinna with a moist surgical sponge.

  16. Heavy-ion damage of an amorphous metallic alloy

    NASA Astrophysics Data System (ADS)

    Chaki, T. K.; Li, J. C. M.

    1986-09-01

    A Ni base amorphous alloy BN12 (Ni 69.2Cr 6.6Si 13.7B 7.9Fe 2.6 supplied by Allied Corporation), with its shiny surface polished and covered with a 20-30 nm Al film to avoid contamination and sputtering, was irradiated with 70 MeV Ni +6 ions at a dose of about {10 16}/{cm 2}. The Al film was removed by 2 g NaOH dissolved in 1 liter water solution. A Dektak surface profilometer showed surface swelling of the irradiated spot by about 200 nm surrounded by higher ridges. Optical and scanning electron microscopic observations revealed considerable roughness within the irradiated spot. Annealing for 3 h at each 50 K. increment of temperature between 500 and 800 K did not remove the swelling. However, transmission electron microscopic studies gave no indication of voids. It seems that swelling may not associate with structural damage. This important possibility is discussed in the light of generation and disappearance of point defects.

  17. Geomicrobiology of Fe-rich crusts in Lake Superior sediment

    NASA Astrophysics Data System (ADS)

    Dittrich, M.; Monreau, L.; Quazi, S.; Raoof, B.; Chesnyuk, A.; Katsev, S.; Fulthorpe, R.

    2012-04-01

    The limnological puzzles of Lake Superior are increasingly attracting scientists, and very little is known about the sediments and their associated microflora. The sediments are organic poor (less than 5%C) and the lake is deep oligotrophic, with water temperatures at the bottom around 3C. Previous studies reveal Fe-rich layers in the sediments at multiple loccations around the lake. The origin and mechanisms of formation of this layer remain unknown. In this study we investigated geochemical and microbiological processes that may lead to the formation of a two cm thick iron layer about 10 cm below the sediment surface. Sediment cores from two stations (EM, 230m water depth and ED, 310m water depth) in the East Basin were used. We monitored oxygen and pH depth profiles with microsensors, porewater and sediment solid matter were analyzed for nutrient and metal contents. Furthermore, phosphorus and iron sequantial extractions of sediment cores have been perfomed. The total cell count was determined using DAPI epifluoresence microscopy. DNA was extracted from the sediment samples and 16S ribosonal RNA amplicons were analyzed with denaturing gradient gel electrophoresis (DGGE). For a more in depth analysis, DNA samples from 8-10 cm and 10-12 cm were sent to the Research and Testing Lab (Texas) for pyrosequencing of 16S rRNA gene amplicons amplified using barcoded universal primers 27f-519r. The scanning electron microscope (SEM) images from the iron layer 10-12cm show filaments that were encrusted with spheres ca. 20 nm in diameter. SEM observations of thin sections also indicate the presence of very fine particles showing various morphologies. Analyses of the deposit material by SEM and energy dispersive X-ray spectroscopy (EDS) indicate that bacteria cells surfaces served as nucleation surfaces for Fe-oxide formation. EDS line-scans through bacterial cells covered with precipitates reveal phosphorus and carbon peaks at interface between cell surface and Fe-particles. The cluster analysis performed on the DGGE separation of ribosomal RNA gene fragments revealed that the two iron layers were not highly similar to each other. We obtained a total of 26,062 16S rRNA gene sequence reads from the two iron layers and the layers directly above them, which were clustered into operational taxonomic units sharing 80% similarity or more. 64-70% of these clusters could not be classified below the phylum level. While the 8-10 cm sediment layers were dominated (46.5% of reads) by relatives of Paenisporosarcina, the iron layers contained far fewer gram positive organisms, far more proteobacteria, and an a high proportion of Nitrospira species which show relatively high similarity to organisms found in an iron II rich seep.

  18. Analysis of disruptive events and precarious situations caused by interaction with neurosurgical microscope.

    PubMed

    Eivazi, Shahram; Afkari, Hoorieh; Bednarik, Roman; Leinonen, Ville; Tukiainen, Markku; Jääskeläinen, Juha E

    2015-07-01

    Developments in micro-neurosurgical microscopes have improved operating precision and ensured the quality of outcomes. Using the stereoscopic magnified view, however, necessitates frequent manual adjustments to the microscope during an operation. This article reports on an investigation of the interaction details concerning a state-of-the-art micro-neurosurgical microscope. The video data from detailed observations of neurosurgeons' interaction patterns with the microscope were analysed to examine disruptive events caused by adjusting the microscope. The primary findings show that interruptions caused by adjusting the microscope handgrips and mouth switch prolong the surgery time up to 10%. Surgeons, we observed, avoid interaction with the microscope's controls, settings, and configurations by working at the edge of the view, operating on a non-focused view, and assuming unergonomic body postures. The lack of an automatic method for adjusting the microscope is a major problem that causes interruptions during micro-neurosurgery. From this understanding of disruptive events, we discuss the opportunities and limitations of interactive technologies that aim to reduce the frequency or shorten the duration of interruptions caused by microscope adjustment.

  19. Site of potential operating microscope light-induced phototoxicity on the human retina during temporal approach eye surgery.

    PubMed

    Pavilack, M A; Brod, R D

    2001-02-01

    To determine the site of focal illumination on the retina of phakic human cadaver eyes from an operating microscope positioned for temporal approach eye surgery. Experimental study. A Zeiss OPMI-6SFR operating microscope (Zeiss Humphrey Systems, Dublin, CA) was positioned over two phakic human cadaver eyes to measure the site of the focal illumination on the retina by directly observing the illumination on the posterior scleral surface of the globe. External localization of the foveola was made by direct observation using scleral indentation and indirect ophthalmoscopy. Various combinations of microscope angulation and field of view were analyzed. Distance of focal illumination from the operating room microscope relative to the foveola was measured. The diameter of the "hot spot" of focal illumination on the retina was 4.0 mm. With the eye positioned straight ahead and the level operating room microscope positioned for temporal approach eye surgery, the center of retinal illumination was 0.9 and 1.4 mm nasal relative to the foveola when the microscope field of view was centered over the cornea and temporal limbus, respectively. With the microscope angled 5, 10, 15, and 20 degrees temporally (oculars tilted toward surgeon), the center of the illumination was displaced nasal to the foveola by 1.1, 1.5, 3.8, and 5.1 mm, respectively, when the field of view was centered over the cornea and 1.5, 2.6, 4.7, and 6.0 mm, respectively, nasal to the foveola when centered over the temporal limbus. Retinal illumination from an operating microscope positioned for temporal approach eye surgery has the potential for light-induced injury to the fovea. Angulation of the operating microscope by up to 10 degrees temporally when the microscope field of view was centered over the cornea and up to 5 degrees temporally when centered over the temporal limbus was not adequate to displace the focal illumination off the foveola when the eye was in the straight-ahead position. Tilting the operating microscope 15 degrees or more temporally when centered on the pupil and 10 degrees or more when centered over the temporal limbus should safely displace the retinal light exposure away from the fovea during temporal approach surgery. Suggestions for reducing the risk of iatrogenic phototoxicity are reviewed.

  20. Gibberellin Biosynthesis in Developing Pumpkin Seedlings12

    PubMed Central

    Lange, Theo; Kappler, Jeannette; Fischer, Andreas; Frisse, Andrea; Padeffke, Tania; Schmidtke, Sabine; Lange, Maria João Pimenta

    2005-01-01

    A gibberellin (GA) biosynthetic pathway was discovered operating in root tips of 7-d-old pumpkin (Cucurbita maxima) seedlings. Stepwise analysis of GA metabolism in cell-free systems revealed the conversion of GA12-aldehyde to bioactive GA4 and inactive GA34. Highest levels of endogenous GA4 and GA34 were found in hypocotyls and root tips of 3-d-old seedlings. cDNA molecules encoding two GA oxidases, CmGA20ox3 and CmGA3ox3, were isolated from root tips of 7-d-old LAB150978-treated seedlings. Recombinant CmGA20ox3 fusion protein converted GA12 to GA9, GA24 to GA9, GA14 to GA4, and, less efficiently, GA53 to GA20, and recombinant CmGA3ox3 protein oxidized GA9 to GA4. Transcript profiles were determined for four GA oxidase genes from pumpkin revealing relatively high transcript levels for CmGA7ox in shoot tips and cotyledons, for CmGA20ox3 in shoot tips and hypocotyls, and for CmGA3ox3 in hypocotyls and roots of 3-d-old seedlings. Transcripts of CmGA2ox1 were mainly found in roots of 7-d-old seedlings. In roots of 7-d-old seedlings, transcripts of CmGA7ox, CmGA20ox3, and CmGA3ox3 were localized in the cap and the rhizodermis by in situ hybridization. We conclude that hypocotyls and root tips are important sites of GA biosynthesis in the developing pumpkin seedling. PMID:16126862

  1. Superconducting Quantum Interferometers for Nondestructive Evaluation

    PubMed Central

    Kostyurina, E. A.; Kalashnikov, K. V.; Maslennikov, Yu. V.; Koshelets, V. P.

    2017-01-01

    We review stationary and mobile systems that are used for the nondestructive evaluation of room temperature objects and are based on superconducting quantum interference devices (SQUIDs). The systems are optimized for samples whose dimensions are between 10 micrometers and several meters. Stray magnetic fields from small samples (10 µm–10 cm) are studied using a SQUID microscope equipped with a magnetic flux antenna, which is fed through the walls of liquid nitrogen cryostat and a hole in the SQUID’s pick-up loop and returned sidewards from the SQUID back to the sample. The SQUID microscope does not disturb the magnetization of the sample during image recording due to the decoupling of the magnetic flux antenna from the modulation and feedback coil. For larger samples, we use a hand-held mobile liquid nitrogen minicryostat with a first order planar gradiometric SQUID sensor. Low-Tc DC SQUID systems that are designed for NDE measurements of bio-objects are able to operate with sufficient resolution in a magnetically unshielded environment. High-Tc DC SQUID magnetometers that are operated in a magnetic shield demonstrate a magnetic field resolution of ~4 fT/√Hz at 77 K. This sensitivity is improved to ~2 fT/√Hz at 77 K by using a soft magnetic flux antenna. PMID:29210980

  2. Operative record using intraoperative digital data in neurosurgery.

    PubMed

    Houkin, K; Kuroda, S; Abe, H

    2000-01-01

    The purpose of this study was to develop a new method for more efficient and accurate operative records using intra-operative digital data in neurosurgery, including macroscopic procedures and microscopic procedures under an operating microscope. Macroscopic procedures were recorded using a digital camera and microscopic procedures were also recorded using a microdigital camera attached to an operating microscope. Operative records were then recorded digitally and filed in a computer using image retouch software and database base software. The time necessary for editing of the digital data and completing the record was less than 30 minutes. Once these operative records are digitally filed, they are easily transferred and used as database. Using digital operative records along with digital photography, neurosurgeons can document their procedures more accurately and efficiently than by the conventional method (handwriting). A complete digital operative record is not only accurate but also time saving. Construction of a database, data transfer and desktop publishing can be achieved using the intra-operative data, including intra-operative photographs.

  3. Navigation lymphatic supermicrosurgery for the treatment of cancer-related peripheral lymphedema.

    PubMed

    Yamamoto, Takumi; Yamamoto, Nana; Numahata, Takao; Yokoyama, Ai; Tashiro, Kensuke; Yoshimatsu, Hidehiko; Narushima, Mitsunaga; Koshima, Isao

    2014-02-01

    Lymphatic supermicrosurgery is becoming the treatment of choice for refractory lymphedema. Detection and anastomosis of functional lymphatic vessels are important for lymphatic supermicrosurgery. Navigation lymphatic supermicrosurgery was performed using an operating microscope equipped with an integrated near-infrared illumination system (OPMI Pentero Infrared 800; Carl Zeiss, Oberkochen, Germany). Eight patients with extremity lymphedema who underwent navigation lymphatic supermicrosurgery were evaluated. A total of 21 lymphaticovenular anastomoses were performed on 8 limbs through 14 skin incisions. Lymphatic vessels were enhanced by intraoperative microscopic indocyanine green (ICG) lymphography in 12 of the 14 skin incisions, which resulted in early dissection of lymphatic vessels. All anastomoses showed good anastomosis patency after completion of anastomoses. Postoperative extremity lymphedema index decreased in all limbs. Navigation lymphatic supermicrosurgery, in which lymphatic vessels are visualized with intraoperative microscopic ICG lymphography, allows a lymphatic supermicrosurgeon to find and dissect lymphatic vessels earlier and facilitates successful performance of lymphaticovenular anastomosis.

  4. Thermoluminescent response of TLD-100 irradiated with 20 keV electrons and the use of radiochromic dye films for the fluence determination

    NASA Astrophysics Data System (ADS)

    Mercado-Uribe, H.; Brandan, M. E.

    2004-07-01

    We have measured the LiF:Mg,Ti (TLD-100) fluence response and supralinearity function to 20 keV electrons in the fluence interval between 5 × 10 9 and 4 × 10 12 cm -2. TLD-100 shows linear response up to 2 × 10 10 cm -2, followed by supralinearity and saturation after 10 12 cm -2. Peak 5 is slightly supralinear, f( n) max=1.1±0.1, while high temperature peaks reach up to f( n) max≈8. Peak 5 saturates at n≈1×10 11 cm -2, fluence smaller than any of the saturating fluences of the high temperature peaks. We have also measured the glow curve shape of TLD-100 irradiated with 40 keV electrons, beta particles from a 90Sr/ 90Y source and 1.3 and 6.0 MeV electrons from accelerators. Results are interesting and unexpected in that, for a given macroscopic dose, electrons show a smaller relative contribution of high-temperature peaks with respect to peak 5 than heavy ions or X- and γ-rays. The 20 and 40 keV electron irradiations were performed with a scanning electron microscope using radiochromic dye film to measure fluence. Since film calibrations were performed using 60Co γ-rays which expose the totality of the film volume, the use of this method with low energy electrons required to develop a formalism that takes into account the sensitive thickness of the film in relation to the range of the incident particles.

  5. [Comparison of anorectal pressure after procedure for prolapse and hemorrhoids versus Doppler-guided hemorrhoidal artery ligation for grade III hemorrhoids].

    PubMed

    Dong, Xiao-ni; Tang, Ying-chun

    2013-12-01

    To compare the long-term anorectal manometry of patients with grade III hemorrhoids treated by procedure for prolapse and hemorrhoids (PPH) or Doppler-guided hemorrhoidal artery ligation (DGHAL). A total of 114 patients with grade III hemorrhoids in our department in 2010 were prospectively enrolled, and divided into PPH group (63 cases) and DGHAL group (51 cases) according to patient preference. Patients received anorectal pressure examination 2, 6, 12, 18 months after operation, including rectal resting pressure, anal resting pressure, maximal anal contractive pressure and length of high-pressure band. Anorectal manometries between two procedure groups were compared. In every time point of follow-up, as compared to PPH group, DGHAL group presented higher anal resting pressure[postoperative 2 months: (56.2±2.6) mmHg vs. (43.2±3.1) mmHg, postoperative 6 months: (55.2±2.1) mmHg vs. (45.1±2.5) mmHg, postoperative 12 months: (53.2±3.0) mmHg vs. (40.2±3.2) mmHg, postoperative 18 months: (55.3±2.6) mmHg vs. (43.2±2.5) mmHg, all P<0.01], and longer length of high-pressure band [postoperative 2 months: (3.45±0.14) cm vs. (2.95±0.22) cm, postoperative 6 months: (3.46±0.12) cm vs. (2.94±0.26) cm, postoperative 12 months: (3.45±0.12) cm vs. (3.01±0.21) cm, postoperative 18 months: (3.56±0.12) cm vs. (3.02±0.23) cm, all P<0.01]. While no significant differences of maximal anal contractive pressure and rectal resting pressure were found between the two groups. Both PPH and DGHAL are safe procedures and have similar efficacy in the treatment of grade III hemorrhoids, while DGHALpossesses better efficacy in the time of anal function recovery and the maintenance of anal function.

  6. Surface profile measurement by using the integrated Linnik WLSI and confocal microscope system

    NASA Astrophysics Data System (ADS)

    Wang, Wei-Chung; Shen, Ming-Hsing; Hwang, Chi-Hung; Yu, Yun-Ting; Wang, Tzu-Fong

    2017-06-01

    The white-light scanning interferometer (WLSI) and confocal microscope (CM) are the two major optical inspection systems for measuring three-dimensional (3D) surface profile (SP) of micro specimens. Nevertheless, in practical applications, WLSI is more suitable for measuring smooth and low-slope surfaces. On the other hand, CM is more suitable for measuring uneven-reflective and low-reflective surfaces. As for aspect of surface profiles to be measured, the characteristics of WLSI and CM are also different. WLSI is generally used in semiconductor industry while CM is more popular in printed circuit board industry. In this paper, a self-assembled multi-function optical system was integrated to perform Linnik white-light scanning interferometer (Linnik WLSI) and CM. A connecting part composed of tubes, lenses and interferometer was used to conjunct finite and infinite optical systems for Linnik WLSI and CM in the self-assembled optical system. By adopting the flexibility of tubes and lenses, switching to perform two different optical measurements can be easily achieved. Furthermore, based on the shape from focus method with energy of Laplacian filter, the CM was developed to enhance the on focal information of each pixel so that the CM can provide all-in-focus image for performing the 3D SP measurement and analysis simultaneously. As for Linnik WLSI, eleven-step phase shifting algorithm was used to analyze vertical scanning signals and determine the 3D SP.

  7. Absolute infrared intensities for F-113 and F-114 and an assessment of their greenhouse warming potential relative to other chlorofluorocarbons

    NASA Astrophysics Data System (ADS)

    Rogers, Jerry D.; Stephens, Robert D.

    1988-03-01

    The literature concerning the "greenhouse" warming potentials of Chlorofluorocarbons F-11, F-12, F-22, F-113, F-114, F-134a, and F-142b is reviewed. Additionally, infrared intensities are reported for each of the fundamental absorption bands of F-113 (CF2ClCFCl2) and F-114 (CF2ClCF2Cl) in the region between 8 and 20 μm. The measurements were made with a Fourier transform infrared spectrometer operated at 0.04 cm-1 apodized resolution. The total intensities measured for this region were 4905 cm-2 atm-1 for F-113 and 6064 cm-2 atm-1 for F-114, compared to a total intensity of 3404 cm-2 atm-1 for F-12 (CF2Cl2) in the same region. On the basis of these infrared intensities and the atmospheric lifetimes of F-113 and of F-114 relative to F-12, and on a per unit mass basis, F-113 and F-114 are about 0.8 and 1.9 times as effective, respectively, as F-12 in the "greenhouse" warming of the Earth.

  8. Chemical composition and efficacy of some selected plant oils against Pediculus humanus capitis in vitro.

    PubMed

    Yones, Doaa A; Bakir, Hanaa Y; Bayoumi, Soad A L

    2016-08-01

    Natural compounds have been suggested as alternative sources for pediculosis capitis control. We aimed to investigate the chemical composition and evaluate the pediculicidal activity of spearmint, clove, cassia, thyme, eucalyptus, and anise essential oils in addition to sesame oil against human head lice in vitro. A filter paper contact bioassay method was used by applying 0.25 and 0.5 mg/cm(2) of each tested oil to filter paper in Petri dishes with 15 females head lice and another with ten nits. The lice mortalities were reported every 5 min for 180 min. The percentage of inhibition of hatch (PIH) was used to calculate ovicidal activity by daily microscopic inspections 5 days after the hatching of controls. Comparison with the widely used pediculicide (malathion) was performed. The most effective essential oil was spearmint followed by cassia and clove with KT50 values of 4.06, 7.62, and 12.12 at 0.5 mg/cm(2) and 8.84, 11.38, and 19.73 at 0.25 mg/cm(2), respectively. Thyme, eucalyptus, and anise were also effective adulticides with KT50 values of 18.61, 32.65, and 37.34 at 0.5 mg/cm(2) and 29.92, 43.16, and 45.37 at 0.25 mg/cm(2), respectively. Essential oils were also successful in inhibiting nymph emergence. Spearmint oil was the most effective, with a complete inhibition of emergence at 0.5 mg/cm(2). Sesame fixed oil did not show any adulticidal or ovicidal activity against head lice in vitro. The observed insecticidal activity was comparable to malathion. The results herein described the effectiveness of these essential oils as potential pediculicides for head lice control. Incorporation of essential oils in pediculicide formulations needs proper formulation and clinical trials.

  9. [Physiological mechanisms of the etiology of visual fatigue during work involving visual stress].

    PubMed

    Korniushina, T A

    2000-01-01

    Physiological parameters of vision were studied in three professional groups (a total of 1204 subjects): microscope operators, subjects working with magnifying glasses, and computer users. General and specific features of visual system fatigue formation were identified. Because of complete (in microscope operators) or partial (in subjects working with magnifying glasses and display users) "deprivation" of accommodation, these subjects develop early presbyopia (at the age of 30-35 years). In microscope operators long strain of accommodation system leads to professional myopia, while display users develop pseudomyopia. The highest overstrain is observed after 4 years of work in microscope operators, after 5 years in magnifying glass users, and after 6 years in computer users.

  10. Renal ablation using magnetic resonance-guided high intensity focused ultrasound: Magnetic resonance imaging and histopathology assessment.

    PubMed

    Saeed, Maythem; Krug, Roland; Do, Loi; Hetts, Steven W; Wilson, Mark W

    2016-03-28

    To use magnetic resonance-guided high intensity focused ultrasound (MRg-HIFU), magnetic resonance imaging (MRI) and histopathology for noninvasively ablating, quantifying and characterizing ablated renal tissue. Six anesthetized/mechanically-ventilated pigs underwent single/double renal sonication (n = 24) using a 3T-MRg-HIFU (1.1 MHz frequency and 3000J-4400J energies). T2-weighted fast spin echo (T2-W), perfusion saturation recovery gradient echo and contrast enhanced (CE) T1-weighted (T1-W) sequences were used for treatment planning, temperature monitoring, lesion visualization, characterization and quantification, respectively. Histopathology was conducted in excised kidneys to quantify and characterize cellular and vascular changes. Paired Student's t-test was used and a P-value < 0.05 was considered statistically significant. Ablated renal parenchyma could not be differentiated from normal parenchyma on T2-W or non-CE T1-W sequences. Ablated renal lesions were visible as hypoenhanced regions on perfusion and CE T1-W MRI sequences, suggesting perfusion deficits and necrosis. Volumes of ablated parenchyma on CE T1-W images in vivo (0.12-0.36 cm(3) for single sonication 3000J, 0.50-0.84 cm(3), for double 3000J, 0.75-0.78 cm(3) for single 4400J and 0.12-2.65 cm(3) for double 4400J) and at postmortem (0.23-0.52 cm(3), 0.25-0.82 cm(3), 0.45-0.68 cm(3) and 0.29-1.80 cm(3), respectively) were comparable. The ablated volumes on 3000J and 4400J double sonication were significantly larger than single (P < 0.01), thus, the volume and depth of ablated tissue depends on the applied energy and number of sonication. Macroscopic and microscopic examinations confirmed the locations and presence of coagulation necrosis, vascular damage and interstitial hemorrhage, respectively. Contrast enhanced MRI provides assessment of MRg-HIFU renal ablation. Histopathology demonstrated coagulation necrosis, vascular damage and confirmed the volume of damage seen on MRI.

  11. Multi-Target Single Cycle Instrument Placement

    NASA Technical Reports Server (NTRS)

    Pedersen, Liam; Smith, David E.; Deans, Matthew; Sargent, Randy; Kunz, Clay; Lees, David; Rajagopalan, Srikanth; Bualat, Maria

    2005-01-01

    This presentation is about the robotic exploration of Mars using multiple targets command cycle, safe instrument placements, safe operation, and K9 Rover which has a 6 wheel steer rocket-bogey chassis (FIDO, MER), 70% MER size, 1.2 GHz Pentium M laptop running Linux OS, Odometry and compass/inclinometer, CLARAty architecture, 5 DOF manipulator w/CHAMP microscopic camera, SciCams, NavCams and HazCams.

  12. Joint Center for Operational Analysis Journal. Volume 12, Issue 1, Spring 2010

    DTIC Science & Technology

    2010-01-01

    enable research into captured records with “complete openness and rigid adherence to acadamic freedom and integrity.” The CRRC will thereby...various levels of effort in the former area, the latter provides a common ground and opportunities for developing close collaborations. This allows...consequence management (CM) capability, specifi cally the use of the CM Decision Support Tool (DST) developed by the DTRA. Ms. Jessica Iannotti

  13. High performance membrane-electrode assembly based on a surface-modified membrane

    NASA Astrophysics Data System (ADS)

    Han, Sangil; Lee, Jang Woo; Kwak, Chan; Chai, Geun Seok; Son, In Hyuk; Jang, Moon Yup; An, Sung Guk; Cho, Sung Yong; Kim, Jun Young; Kim, Hyung Wook; Serov, Alexey Alexandrovych; Yoo, Youngtai; Nam, Kie Hyun

    A surface-modified membrane is prepared using a sputtering technique that deposits gold directly on a Nafion ® 115 membrane surface that is roughened with silicon carbide paper. The surface-modified membranes are characterized by means of a scanning electron microscope (SEM), differential scanning calorimetry (DSC), and water contact-angle analysis. A single direct methanol fuel cell (DMFC) with a surface-modified membrane exhibits enhanced performance (160 mW cm -2), while a bare Nafion ® 115 cell yields 113 mW cm -2 at 0.4 V and an operating temperature of 70 °C. From FE-SEM images and CO ad stripping voltammograms, it is also found that the gold layer is composed of clusters of porous nodule-like particles, which indicates that an anode with nodule-like gold leads to the preferential oxidation of carbon monoxide. These results suggest that the topology of gold in the interfacial area and its electrocatalytic nature may be the critical factors that affect DMFC performance.

  14. [BIPADDLED SPLIT PECTORALIS MAJOR MYOCUTANEOUS FLAPS FOR IMMEDIATE RECONSTRUCTION OF ORAL MUCOSAL DEFECTS AND NECK DEFECTS AFTER RESECTION OF RECURRENT ORAL CANCER].

    PubMed

    Chen, Jie; Jiang, Canhua; Li, Ning; Gao, Zhengyang; Chen, Lichun; Wu, Xiaoshan; Chen, Xinqun; Jian, Xinchun

    2015-07-01

    To investigate the feasibility of the bipaddled split pectoralis major myocutaneous flap for immediate reconstruction of oral mucosal defects and neck defects after resection of recurrent oral cancer. Six patients with oral mucosal defects combined with neck defects after recurrent oral cancer resection were treated with bipaddled split pectoralis major myocutaneous flap between September 2013 and September 2014. There were 5 males and 1 female with an average age of 54.7 years (range, 45-62 years), including 4 cases of recurrent tongue cancer, 1 case of recurrent mandibular gingival cancer, and 1 case of mouth floor carcinoma. All patients underwent local recurrence at 8 to 14 months after first operation, with no distant metastasis. The defects of the intraoral mucosa was 4.0 cm x 2.5 cm to 6.5 cm x 3.5 cm and the defect of the neck skin was 5.5 cm x 3.5 cm to 7.5 cm x 5.0 cm. The pectoralis major myocutaneous flaps (14.0 cm x 3.5 cm to 17.0 cm x 5.5 cm) were incised at the level of the 3rd to the 4th rib, and then split down along the muscle fiber till about 2 cm away from the thoracoacromial vessels, forming 2 independent skin paddles with 1-2 branch vessels to the pedicles of the distal ones. The distal skin paddles were used for oral reconstruction while the proximal paddles for repair of neck defects. The chest donor sites were sutured directly. Cervical haematoma and infection happened in 1 patient respectively after operation, and were cured after symptomatic treatment. All 6 split pectoralis major myocutaneous flaps with 12 skin paddles completely survived. All patients were followed up 6 to 18 months (mean, 11 months). One patient died of pulmonary metastasis at 8 months after operation and the other 5 survived without relapse or metastasis during follow-up. The intraoral paddles showed good shape with satisfactory speech function and swallowing recovery. The paddles also healed perfectly on the neck with flat outlooks, and all patients obtained full appearance and free movement of the neck. No fistula formed on the submandibular region and neck. The bipaddled split pectoralis major myocutaneous flap can complete simultaneous immediate reconstruction of oral mucosal defect and neck defect. It is very useful in the treatment of recurrent oral cancer.

  15. Atypical myxoma.

    PubMed

    Hwang, J J; Lien, W P; Kuan, P; Hung, C R; How, S W

    1991-08-01

    We report the case of a 38-year-old woman with a large thin-walled cystic mass (6 x 5 x 4.5 cm) filled with arterial blood in the right atrium. The cystic mass with blood content was clearly delineated by transesophageal cross-sectional echocardiography and magnetic resonance imaging of the heart. At operation, a silver-whitish, smooth surfaced cystic mass was found attached to the free wall of the right atrium between the superior vena cava and the right atrial appendage with a broad base. Microscopically, the wall of the cyst was composed of stellate mesenchymal cells embedded within a myxoid matrix which was proved by alcian blue stain. To our knowledge, this type of cardiac myxoma has not been previously reported.

  16. METHOD OF OPPOSING IRRADIATION-INDUCED VISCOSITY INCREASE IN EMPLOYMENT OF ORGANIC FLUIDS

    DOEpatents

    Balt, R.O.

    1961-10-24

    A method is described for conducting mechanical operations necessitating the use of a lubricant in a medium operaject to reactor irradiation of 0.5 x 10/ sup 12/ to 1 x 10/sup 12/ neut rons/ cm/sup 2//sec. A thiopolyether lubricant such as 16, 19-dioxa-13, 22-dithiatetratriacontane is used. (AEC)

  17. Robotic Assisted Microsurgery - RAMS FY'97

    NASA Technical Reports Server (NTRS)

    1997-01-01

    JPL and Microdexterity Systems collaborated to develop new surgical capabilities. They developed a Robot Assisted Microsurgery (RAM) tool for surgeons to use for operating on the eye, ear, brain, and blood vessels with unprecedented dexterity. A surgeon can hold the surgical instrument with motions of 6 degrees of freedom with an accuracy of 25 microns in a 70 cu cm workspace. In 1996 a demonstration was performed to remove a microscopic particle from a simulated eyeball. In 1997, tests were performed at UCLA to compare telerobotics with mechanical operations. In 5 out of 7 tests, the RAM tool performed with a significant improvement of preciseness over mechanical operation. New design features include: (1) amplified forced feedback; (2) simultaneous slave robot instrumentation; (3) index control switch on master handle; and (4) tool control switches. Upgrades include: (1) increase in computational power; and (2) installation of hard disk memory storage device for independent operation and independent operation of forceps. In 1997 a final demonstration was performed using 2 telerobotics simultaneously in a microsurgery suture procedure to close a slit in a thin sheet of latex rubber which extended the capabilities of microsurgery procedures. After completing trials and demonstrations for the FDA the potential benefits for thousands of operations will be exposed.

  18. [Effects of anteriolateral thigh perforator flap and fascia lata transplantation in combination with computed tomography angiography on repair of electrical burn wounds of head with skull exposure and necrosis].

    PubMed

    Li, X Q; Wang, X; Han, Y L; Ji, G; Chen, Z H; Zhang, J; Zhu, J P; Duan, J X; He, Y J; Yang, X M; Liu, W J

    2018-05-20

    Objective: To explore the effects of anteriolateral thigh perforator flap and fascia lata transplantation in combination with computed tomography angiography (CTA) on repair of electrical burn wounds of head with skull exposure and necrosis. Methods: Seven patients with head electrical burns accompanied by skull exposure and necrosis were admitted to our burn center from March 2016 to December 2017. Head CTA was performed before the operation. The diameters of the facial artery and vein or the superficial temporal artery and vein were measured, and their locations were marked on the body surface. Preoperative CTA for flap donor sites in lower extremities were also performed to track the descending branch of the lateral circumflex femoral artery with the similar diameter as the recipient vessels on the head, and their locations were marked on the body surface. Routine wound debridement and skull drilling were performed successively. The size of the wounds after debridement ranged from 12 cm×8 cm to 20 cm×12 cm, and the areas of skull exposure ranged from 8 cm×6 cm to 15 cm×10 cm. Anteriolateral thigh perforator flaps with areas from 13 cm×9 cm to 21 cm×13 cm containing 5-10 cm long vascular pedicles were designed and dissected accordingly. The fascia lata under the flap with area from 5 cm×2 cm to 10 cm×3 cm was dissected according to the length of vascular pedicle. The fascia lata was transplanted to cover the exposed skull, and the anteriolateral thigh perforator flap was transplanted afterwards. The descending branch of the lateral circumflex femoral artery and its accompanying vein of the flap were anastomosed with superficial temporal artery and vein or facial artery and vein before the suture of flap. The flap donor sites were covered by intermediate split-thickness skin graft collected from contralateral thigh or abdomen. Results: The descending branch of the lateral circumflex femoral artery and its accompanying vein were anastomosed with superficial temporal artery and vein in six patients, while those with facial artery and vein in one patient. All the flaps survived after the operation, and no vascular crisis was observed. Wound healing was satisfactory. One patient was lost to follow up. Six patients were followed up for 6 to 10 months. The patients were bald in the head operation area with acceptable appearance. No psychiatric symptom such as headache or epileptic seizure was reported. The flap donor sites were normal in appearance. The muscle strength of the lower extremities all reached grade V. The sensation and movement of the lower extremities were normal. Conclusions: Anterolateral thigh perforator flap with fascia lata transplantation can effectively repair electrical burn wounds of head with skull exposure and necrosis. The fascia lata can be used to protect the vascular pedicle of flaps, which is beneficial to the survival of the flap. Preoperative head and lower extremities CTA can provide reference for intraoperative vascular exploration in donor site and recipient area, so as to shorten operation time.

  19. Measurement of dew droplets in initial deposition at dew point by using a phase-shift interference microscope

    NASA Astrophysics Data System (ADS)

    Matsumoto, Shigeaki; Toyooka, Satoru; Hoshino, Mitsuo

    2002-09-01

    In order to measure the total mass per unit area of dew droplets deposited on a metal plate in the dew-point hygrometer, the shape of a dew droplet deposited on a copper plate was measured accurately by using an interference microscope that employed a phase-shift technique. The microscope was constructed by adding a piezoelectric transducer to an usual interference microscope. A simple method that uses a conventional speaker horn and an optical fiber cable was introduced to depress speckle noise. The shape of a dew droplet deposited on the copper plate surface with 0.1 μm in average roughness was measured with an accuracy of +/-3nm. The mass of a dew droplet could be calculated numerically from the volume of its shape and was of the order of 10-9 g. The total mass of dew droplets deposited per unit area and the deposition velocity were obtained under a gentle wind. The total mass was the order of 10-5 g/cm2 at the beginning of deposition and the deposition velocity was ranged from 2x10-6 to 6x10-5 g/cm2.min.

  20. The measurement of tiny dew droplets at the initial deposition stage and dew point using a phase-shift interference microscope

    NASA Astrophysics Data System (ADS)

    Shigeaki, Matsumoto

    2003-12-01

    The shape of a dew droplet deposited on the mirror surface of a copper plate was measured accurately using an interference microscope that employed a phase-shift technique. The microscope was constructed by adding a piezoelectric transducer to an interference microscope. A simple method that uses a conventional speaker horn and an optical fibre cable was used to depress any speckle noise. The shape of a dew droplet deposited at dew point on the plate surface with average roughness of 0.1 µm was measured with an accuracy of ± 3 nm. The mass of a tiny dew droplet could be determined from the volume of its shape and was of the order of 10-9 g. The total mass of a dew droplet deposited per unit area and the deposition velocity under a gentle wind were also obtained in a similar way. The total mass was of the order of 10-5 g cm-2 at the beginning of deposition and the deposition velocity ranged from 1 × 10-5 to 6 × 10-5 g cm-2 min-1 at room temperature.

  1. Dynamic cooling during laser skin welding

    NASA Astrophysics Data System (ADS)

    Fried, Nathaniel M.; Walsh, Joseph T., Jr.

    1999-06-01

    Cryogen spray cooling of the tissue surface was investigated for laser welding applications. Benefits include reduced thermal damage to the papillary dermis and reduced operation time. Two-cm-long, full-thickness incisions were made on the backs of guinea pigs, in vivo. India ink was used as an absorber and clamps were used to appose the incision edges. Continuous-wave, 1.06-μm, Nd:YAG laser radiation was scanned over the incisions, producing ~100 ms pulses. A 4-mm-diameter laser spot was used with a constant power of 16 W. The total operation time was 60 or 120 s. Cryogen was delivered in spurt durations of 20, 60, or 100 ms, with 2 or 4 s between spurts. The working distance was approximately 12 cm, and the spray covered an area of about 5.0 x 5.0 cm. Control welds were irradiated for 20, 40, or 60 s. Total operation times were reduced from 10 min without dynamic cooling to 1 min with dynamic cooling. Optimal tensile strength was 1.7 +/- 0.7 kg/cm2, comparible to stengths of 2.1 +/- 0.7 kg/cm2 reported in previous studies without cryogen cooling (p>0.25). Thermal damage in the papillary dermis measured 320 +/- 80 μm.

  2. Preparing and Restoring Composite Resin Restorations. The Advantage of High Magnification Loupes or the Dental Surgical Operating Microscope.

    PubMed

    Mamoun, John

    2015-01-01

    Use of magnification, such as 6x to 8x binocular surgical loupes or the surgical operating microscope, combined with co-axial illumination, may facilitate the creation of stable composite resin restorations that are less likely to develop caries, cracks or margin stains over years of service. Microscopes facilitate observation of clinically relevant microscopic visual details, such as microscopic amounts of demineralization or caries at preparation margins; microscopic areas of soft, decayed tooth structure; microscopic amounts of moisture contamination of the preparation during bonding; or microscopic marginal gaps in the composite. Preventing microscope-level errors in composite fabrication can result in a composite restoration that, at initial placement, appears perfect when viewed under 6x to 8x magnification and which also is free of secondary caries, marginal staining or cracks at multi-year follow-up visits.

  3. Disk-accreting magnetic neutron stars as high-energy particle accelerators

    NASA Technical Reports Server (NTRS)

    Hamilton, Russell J.; Lamb, Frederick K.; Miller, M. Coleman

    1994-01-01

    Interaction of an accretion disk with the magnetic field of a neutron star produces large electromotive forces, which drive large conduction currents in the disk-magnetosphere-star circuit. Here we argue that such large conduction currents will cause microscopic and macroscopic instabilities in the magnetosphere. If the minimum plasma density in the magnetosphere is relatively low is less than or aproximately 10(exp 9)/cu cm, current-driven micro-instabilities may cause relativistic double layers to form, producing voltage differences in excess of 10(exp 12) V and accelerating charged particles to very high energies. If instead the plasma density is higher (is greater than or approximately = 10(exp 9)/cu cm, twisting of the stellar magnetic field is likely to cause magnetic field reconnection. This reconnection will be relativistic, accelerating plasma in the magnetosphere to relativistic speeds and a small fraction of particles to very high energies. Interaction of these high-energy particles with X-rays, gamma-rays, and accreting plasma may produce detectable high-energy radiation.

  4. Imaging System for Vaginal Surgery.

    PubMed

    Taylor, G Bernard; Myers, Erinn M

    2015-12-01

    The vaginal surgeon is challenged with performing complex procedures within a surgical field of limited light and exposure. The video telescopic operating microscope is an illumination and imaging system that provides visualization during open surgical procedures with a limited field of view. The imaging system is positioned within the surgical field and then secured to the operating room table with a maneuverable holding arm. A high-definition camera and Xenon light source allow transmission of the magnified image to a high-definition monitor in the operating room. The monitor screen is positioned above the patient for the surgeon and assistants to view real time throughout the operation. The video telescopic operating microscope system was used to provide surgical illumination and magnification during total vaginal hysterectomy and salpingectomy, midurethral sling, and release of vaginal scar procedures. All procedures were completed without complications. The video telescopic operating microscope provided illumination of the vaginal operative field and display of the magnified image onto high-definition monitors in the operating room for the surgeon and staff to simultaneously view the procedures. The video telescopic operating microscope provides high-definition display, magnification, and illumination during vaginal surgery.

  5. Optimizing Aerosol Dispensers for Mating Disruption of Codling Moth, Cydia pomonella L.

    PubMed

    McGhee, Peter S; Miller, James R; Thomson, Donald R; Gut, Larry J

    2016-07-01

    Experiments were conducted in commercial apple orchards to determine if improved efficiencies in pheromone delivery may be realized by using aerosol pheromone dispensers for codling moth (CM), Cydia pomonella L., mating disruption. Specifically, we tested how reducing: pheromone concentration, period of dispenser operation, and frequency of pheromone emission from aerosol dispensers affected orientational disruption of male CM to pheromone-baited monitoring traps. Isomate® CM MIST formulated with 50 % less codlemone (3.5 mg/ emission) provided orientation disruption equal to the standard commercial formulation (7 mg / emission). Decreased periods of dispenser operation (3 and 6 h) and frequency of pheromone emission (30 and 60 min) provided a level of orientational disruption similar to the current standard protocol of releasing pheromone over a 12 h period on a 15 min cycle, respectively. These three modifications provide a means of substantially reducing the amount of pheromone necessary for CM disruption. The savings accompanying pheromone conservation could lead to increased adoption of CM mating disruption and, moreover, provide an opportunity for achieving higher levels of disruption by increasing dispenser densities.

  6. In vitro pediculicidal activity of herbal shampoo base on Thai local plants against head louse (Pediculus humanus capitis De Geer).

    PubMed

    Rassami, Watcharawit; Soonwera, Mayura

    2013-04-01

    Head lice infestation, a worldwide head infestation caused Pediculus humanus capitis De Geer, is an important public health problem in Thailand. Several chemical pediculicides have lost in efficacy due to increasing resistance of lice against insecticide. Therefore, non-toxic alternative products, such as natural products from plants, e.g. plant extract pediculicides, are needed for head lice control. The aims of this study were to evaluate the potential of pediculicidal activity of herbal shampoo base on three species of Thai local plants (Accacia concinna (Willd.) DC, Averrhoa bilimbi Linn. and Tamarindus indica Linn.) against head lice and to compare them with carbaryl shampoo (Hafif shampoo®; 0.6% w/v carbaryl) and non-treatment control in order to assess their in vitro. Doses of 0.12 and 0.25 ml/cm2 of each herbal shampoo were applied to filter paper, and ten head lice were place on the filter paper. The mortalities of head lice on the filter paper were recorded at 1, 5, 10, 30 and 60 min by sterio-microscope. All herbal shampoos at 0.25 ml/cm2 were more effective pediculicide than carbaryl shampoo with 100% mortality at 5 min. The median lethal time (LT50) of all herbal shampoos at 0.25 ml/cm2 showed no significant differences over at 0.12 ml/cm2 (P<0.01). The most effective pediculicide was T. indica extract shampoo, followed by Av. bilimbi extract shampoo and Ac. concinna extract shampoo, with LT50 values<1.0 min. Our data showed that all herbal shampoos have high potential of pediculicide to head lice treatments for schoolchildren.

  7. Safety of laser use under the dental microscope.

    PubMed

    Saegusa, Hidetoshi; Watanabe, Satoshi; Anjo, Tomoo; Ebihara, Arata; Suda, Hideaki

    2010-04-01

    The aim of this study was to investigate the safety of laser use under the dental microscope. Nd:YAG, Er:YAG and diode lasers were used. The end of the tips was positioned at a distance of 5 cm from the objective lens of a dental microscope. Each eye protector was made into a flat disc, which was fixed on the lens of the microscope. The filters were placed in front of the objective lens or behind the eye lens. Transmitted energy through the microscope with or without the filters was measured. No transmitted laser energy was detected when using matched eye protectors. Mismatched eye protectors were not effective for shutting out laser energy, especially for Nd:YAG and diode lasers. None or very little laser energy was detected through the microscope even without any laser filter. Matched filters shut out all laser energy irrespective of their positions.

  8. Measurement area and repeatability of semiautomated assessment of corneal endothelium in the Topcon specular microscope SP-2000P and IMAGEnet system.

    PubMed

    Ding, Xiaohu; Huang, Qunxiao; Zheng, Yingfeng; Jiang, Yuzhen; Huang, Shengsong; He, Mingguang

    2012-10-01

    To investigate the repeatability of the semiautomatic assessment of corneal endothelial cells and its association with the measurement area in the Topcon SP-2000P microscope and IMAGEnet system. Specular microscopic images of 86 healthy subjects were captured and analyzed using the Topcon SP-2000P microscope and IMAGEnet system. The same images were analyzed twice, on separate days, by the same examiner using the built-in measurement tool of the IMAGEnet system. The measurement areas were defined with a frame mounted on a computer screen. Four different-sized measurement areas were chosen for the semiautomatic measurements: box A (5.4 × 13.9 cm(2)), box B (4 × 10 cm(2)), box C (4 × 7 cm(2)), and box D (2 × 5 cm(2)). Average cell size (ACS), endothelial cell density (ECD), coefficient of variance, and hexagonality were measured. Repeatability was assessed based on the limit of agreement (LOA). The means of ACS, ECD, and hexagonality were not statistically different across 4 measurement areas (analysis of variance, P > 0.05). The mean differences (bias) were modest for ACS (range, -1.9∼3.9 μm(2)), ECD (range, -27.2∼14.6 cells per square millimeter), coefficient of variance (range, -0.14∼1.00), and hexagonality (range, -1.3%∼6.8%). Limits of agreement (mean difference ± 1.96× SD) were greater in the measurements with smaller areas: limit of agreement values for ECD were 14.6 ± 99.6, -3.8 ± 101.1, -27.2 ± 179, and -15.8 ± 488 cells per square millimeter for boxes A, B, C, and D, respectively. Similar trends were found in the repeatability of ACS and hexagonality. Repeatability is improved when larger measurement areas are chosen.

  9. Frequency of second mesiobuccal canal in permanent maxillary first molars using the operating microscope and selective dentin removal: A clinical study.

    PubMed

    Das, Suroopa; Warhadpande, Manjusha M; Redij, Saurabh A; Jibhkate, N G; Sabir, Husain

    2015-01-01

    The aim of this study was to investigate whether the combination of operating microscope and selective dentin removal increased the frequency of second mesiobuccal (MB2) canal detection in permanent maxillary first molar teeth. One hundred fifty permanent maxillary first molars indicated for root canal treatment were randomly selected from patients belonging to the age group of 18-45 years irrespective of gender. After access cavity preparation and location of main canals, the MB2 canal orifice was sought in all teeth with an endodontic explorer under direct vision (Stage I), then under magnification with the aid of operating microscope (Stage II) and finally with the combined use of operating microscope and selective dentin removal (Stage III). MB2 canals were detected in 36%, 54% and 72% of the teeth in Stages I-III, respectively. This study demonstrated that dental operating microscope when used along with adjunctive aids such as selective dentin removal/troughing and good clinical knowledge will increase the ability of dental clinician to locate MB2 canals.

  10. Return-to-play outcomes after microscopic lumbar diskectomy in professional athletes.

    PubMed

    Watkins, Robert G; Hanna, Robert; Chang, David; Watkins, Robert G

    2012-11-01

    It has been shown a microscopic lumbar diskectomy (MLD) is effective in getting professional athletes back to their sport after a herniated nucleus pulposus (HNP). There is a need for more information on the time it takes professional athletes to return after surgery. To determine average time for return to play and success in returning to play for professional athletes undergoing MLD. Case series; Level of evidence, 4. Between 1996 and 2010, the senior authors treated 171 professional athletes for lumbar HNP. A retrospective review was performed using patient charts, operative reports, team medical records, and internet search. Eighty-five patients were treated with MLD, and 86 patients were treated nonoperatively. This study focused on the return to play of the operatively treated patients. Primary outcome measures were return rate and average return time, considering only patients whose sport is in season at specific postoperative time points. Of surgically treated patients, 89.3% returned to sport. The average time it took operative patients to return to their sport (return time) was 5.8 months. Progressive return data for surgically treated patients showed the percentage of athletes who returned increased from 50% at 3 months to 72% at 6 months to 77% at 9 months and 84% at 12 months. The chance a player returns to play after MLD is 50% at 3 months, 72% at 6 months, 77% at 9 months, and 84% at 12 months. The overall chance of returning to play at any point is 89%.

  11. Structural and electronic properties of extremely long perylene bisimide nanofibers formed through a stoichiometrically mismatched, hydrogen-bonded complexation.

    PubMed

    Yagai, Shiki; Seki, Tomohiro; Murayama, Haruno; Wakikawa, Yusuke; Ikoma, Tadaaki; Kikkawa, Yoshihiro; Karatsu, Takashi; Kitamura, Akihide; Honsho, Yoshihito; Seki, Shu

    2010-12-06

    Extremely long nanofibers, whose lengths reach the millimeter regime, are generated via co-aggregation of a melamine-appended perylene bisimide semiconductor and a substituted cyanurate, both of which are ditopic triple-hydrogen-bonding building blocks; they co-aggregate in an unexpected stoichiometrically mismatched 1:2 ratio. Various microscopic and X-ray diffraction studies suggest that hydrogen-bonded polymeric chains are formed along the long axis of the nanofibers by the 1:2 complexation of the two components, which further stack along the short axis of the nanofibers. The photocarrier generation mechanism in the nanofibers is investigated by time-of-flight (TOF) experiments under electric and magnetic fields, revealing the birth and efficient recombination of singlet geminate electron-hole pairs. Flash-photolysis time-resolved microwave conductivity (FP-TRMC) measurements revealed intrinsic 1D electron mobilities up to 0.6 cm(2) V(-1) s(-1) within nanofibers.

  12. IMIS: An intelligence microscope imaging system

    NASA Technical Reports Server (NTRS)

    Caputo, Michael; Hunter, Norwood; Taylor, Gerald

    1994-01-01

    Until recently microscope users in space relied on traditional microscopy techniques that required manual operation of the microscope and recording of observations in the form of written notes, drawings, or photographs. This method was time consuming and required the return of film and drawings from space for analysis. No real-time data analysis was possible. Advances in digital and video technologies along with recent developments in article intelligence will allow future space microscopists to have a choice of three additional modes of microscopy: remote coaching, remote control, and automation. Remote coaching requires manual operations of the microscope with instructions given by two-way audio/video transmission during critical phases of the experiment. When using the remote mode of microscopy, the Principal Investigator controls the microscope from the ground. The automated mode employs artificial intelligence to control microscope functions and is the only mode that can be operated in the other three modes as well. The purpose of this presentation is to discuss the advantages and disadvantages of the four modes of of microscopy and how the IMIS, a proposed intelligent microscope imaging system, can be used as a model for developing and testing concepts, operating procedures, and equipment design of specifications required to provide a comprehensive microscopy/imaging capability onboard Space Station Freedom.

  13. Electrically stimulated contractions of Vorticella convallaria

    NASA Astrophysics Data System (ADS)

    Kantha, Deependra; van Winkle, David

    2009-03-01

    The contraction of Vorticella convallaria was triggered by applying a voltage pulse in its host culturing medium. The 50V, 1ms wide pulse was applied across platinum wires separated by 0.7 cm on a microscope slide. The contractions were recorded as cines (image sequences) by a Phantom V5 camera (Vision Research) on a bright field microscope with 20X objective, with the image size of 256 pixels x 128 pixels at 7352 pictures per second. The starting time of the cines was synchronized with the starting of the electrical pulse. We recorded five contractions of each of 12 organisms. The cines were analyzed to obtain the initiation time, defined as the difference in time between the leading edge of the electrical pulse and the first frame showing zooid movement. From multiple contractions of same organism, we found the initiation time is reproducible. In comparing different organisms, we found the average initiation time of 1.73 ms with a standard deviation of 0.63 ms. This research is supported by the state of Florida (MARTECH) and Research Corporation.

  14. Objective Measures for the Assessment of Post-Operative Pain in Bos indicus Bull Calves Following Castration

    PubMed Central

    Musk, Gabrielle C.; Hyndman, Timothy H.; Lehmann, Heidi S.; Tuke, S. Jonathon; Collins, Teresa; Johnson, Craig B.

    2017-01-01

    Simple Summary Surgical castration of cattle is a common husbandry procedure, and although this procedure is known to cause pain in cattle and other species, in some countries it is often performed without anaesthesia or analgesia. Society is increasingly aware of this animal welfare issue and it is creating pressure to drive research into animal welfare science with the aim of identifying practical and economical approaches to pain management in livestock. To effectively manage pain, a pain assessment must be performed. Pain assessment methods are often subjective and therefore influenced by the observer. Ideally, objective assessments that generate consistent and repeatable results between observers should be identified. Bos indicus bull calves were divided into four groups: no castration (NC, n = 6); castration with pre-operative local anaesthetic (CL n = 12); castration with pre-operative anti-inflammatory medication (CM, n = 12); and, castration without pain relief (C, n = 12). A range of objective assessments was performed: bodyweight measurements, activity, and rest levels, and four different compounds in the blood. The results of this study suggest that animals rest for longer periods after the pre-operative administration of anti-inflammatory medication. The other objective assessments measured in this study were not able to consistently differentiate between treatment groups. These findings emphasise the need for alternative quantifiable and objective indicators of pain in Bos indicus bull calves. Abstract The aim of the study was to assess pain in Bos indicus bull calves following surgical castration. Forty-two animals were randomised to four groups: no castration (NC, n = 6); castration with pre-operative lidocaine (CL, n = 12); castration with pre-operative meloxicam (CM, n = 12); and, castration alone (C, n = 12). Bodyweight was measured regularly and pedometers provided data on activity and rest from day −7 (7 days prior to surgery) to 13. Blood was collected for the measurement of serum amyloid A (SAA), haptoglobin, fibrinogen, and iron on days 0, 3 and 6. Bodyweight and pedometry data were analysed with a mixed effect model. The blood results were analysed with repeated measure one-way analysis of variance (ANOVA). There was no treatment effect on bodyweight or activity. The duration of rest was greatest in the CM group and lowest in the C group. There was a significant increase in the concentrations of SAA, haptoglobin, and fibrinogen in all of the groups from day 0 to 3. Iron concentrations were not different at the time points it was measured. The results of this study suggest that animals rest for longer periods after the pre-operative administration of meloxicam. The other objective assessments measured in this study were not able to consistently differentiate between treatment groups. PMID:28956843

  15. VizieR Online Data Catalog: The Fermi-GBM three-year X-ray burst catalog (Jenke+, 2016)

    NASA Astrophysics Data System (ADS)

    Jenke, P. A.; Linares, M.; Connaughton, V.; Beklen, E.; Camero-Arranz, A.; Finger, M. H.; Wilson-Hodge, C. A.

    2018-03-01

    Gamma-ray Burst Monitor (GBM) is an all-sky monitor whose primary objective is to extend the energy range over which gamma-ray bursts are observed in the Large Area Telescope on Fermi (Meegan et al. 2009ApJ...702..791M). GBM consists of 12 NaI detectors with a diameter of 12.7 cm and a thickness of 1.27 cm and two bismuth germanate (BGO) detectors with a diameter and thickness of 12.7 cm. GBM has three continuous data types: CTIME data with nominal 0.256 s time resolution and 8-channel spectral resolution used for event detection and localization, CSPEC data with nominal 4.096 s time resolution and 128-channel spectral resolution, which are used for spectral modeling, and CTTE (continuous-time tagged event) data with time stamps (2 μs precision) on individual events at full 128-channel spectral resolution, which were made available in 2012 November. The Fermi-GBM X-ray Burst Monitor relies on daily inspection of CTIME channel 1 (12-25 keV) data and began operations on 2010 March 12. (3 data files).

  16. Initial results from the NASA Lewis Bumpy Torus experiment. [of steady-state ion heating method based on modified Penning discharge

    NASA Technical Reports Server (NTRS)

    Roth, J. R.; Richardson, R. W.; Gerdin, G. A.

    1973-01-01

    Initial results were obtained from low power operation of the NASA Lewis Bumpy Torus experiment, in which a steady-state ion heating method based on the modified Penning discharge is applied in a bumpy torus confinement geometry. The magnet facility consists of 12 superconducting coils, each 19 cm i.d. and capable of 3.0 T, equally spaced in a toroidal array 1.52 m in major diameter. A 18 cm i.d. anode ring is located at each of the 12 midplanes and is maintained at high positive potentials by a dc power supply. Initial observations indicate electron temperatures from 10 to 150 eV, and ion kinetic temperatures from 200 eV to 1200 eV. Two modes of operation were observed, which depend on background pressure, and have different radial density profiles. Steady state neutron production was observed. The ion heating process in the bumpy torus appears to parallel closely the mechanism observed when the modified Penning discharge was operated in a simple magnetic mirror field.

  17. A variable-temperature nanostencil compatible with a low-temperature scanning tunneling microscope/atomic force microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steurer, Wolfram, E-mail: wst@zurich.ibm.com; Gross, Leo; Schlittler, Reto R.

    2014-02-15

    We describe a nanostencil lithography tool capable of operating at variable temperatures down to 30 K. The setup is compatible with a combined low-temperature scanning tunneling microscope/atomic force microscope located within the same ultra-high-vacuum apparatus. The lateral movement capability of the mask allows the patterning of complex structures. To demonstrate operational functionality of the tool and estimate temperature drift and blurring, we fabricated LiF and NaCl nanostructures on Cu(111) at 77 K.

  18. A variable-temperature nanostencil compatible with a low-temperature scanning tunneling microscope/atomic force microscope.

    PubMed

    Steurer, Wolfram; Gross, Leo; Schlittler, Reto R; Meyer, Gerhard

    2014-02-01

    We describe a nanostencil lithography tool capable of operating at variable temperatures down to 30 K. The setup is compatible with a combined low-temperature scanning tunneling microscope/atomic force microscope located within the same ultra-high-vacuum apparatus. The lateral movement capability of the mask allows the patterning of complex structures. To demonstrate operational functionality of the tool and estimate temperature drift and blurring, we fabricated LiF and NaCl nanostructures on Cu(111) at 77 K.

  19. [Microsurgery, a 'small' surgical revolution in the medical history of the 20th century].

    PubMed

    Haeseker, B

    1999-04-17

    Microsurgery in the twentieth century enabled surgeons to operate on very fine structures, which was impossible before the advent of the microscope. Since 1860 loupe magnification was employed in rare cases. In 1921 Nylén from Sweden transformed an ordinary laboratory microscope into an operation microscope for ear interventions. The eye specialists were the second group of doctors who employed the microscope in the operating theatre during the years 40-50 of this century. Since 1953 Zeiss in Germany has produced highly professional operation microscopes. In the sixties experimental laboratory studies were taken up to develop microsurgical techniques, microinstruments and suture material. Both plastic and reconstructive surgeons and neurosurgeons continued to develop microsurgery and indeed transformed their disciplines a great deal. Microsurgery is here to stay and still experiments are going on with video-assisted systems in order to further miniaturize the instruments for magnification and to gain a more comfortable working position for the surgeon.

  20. DO-increasing effects of a microscopic bubble generating system in a fish farm.

    PubMed

    Endo, Akira; Srithongouthai, Sarawut; Nashiki, Hisatsune; Teshiba, Ichiro; Iwasaki, Takaaki; Hama, Daigo; Tsutsumi, Hiroaki

    2008-01-01

    We have developed a "microscopic bubble generating system for the fish farm" and evaluated its ability to improve the quality of seawater and costs of it in marine cages of red sea bream (Pagrus major) in Kusuura Bay, Japan. Our results revealed that DO concentration of bubbling net pens increased and became significantly higher than the level outside the net pen (between 0.52 and 0.87 mg/L), and the whole water column was nearly saturated. Temperatures of the bubbling net pens decreased slightly between 0.08 and 0.12 degrees C in all the layers. Furthermore, micro-bubbles seemed to reach the deeper water due to the downward flow and diffusion. This study demonstrated that the microscopic bubble generating system developed in our research project could increase efficiently the dissolved oxygen concentration throughout all water layers of the fish farm. A capital and operation costs of the system is recoverable within a year.

  1. Bone Marrow Stem Cells and Ear Framework Reconstruction.

    PubMed

    Karimi, Hamid; Emami, Seyed-Abolhassan; Olad-Gubad, Mohammad-Kazem

    2016-11-01

    Repair of total human ear loss or congenital lack of ears is one of the challenging issues in plastic and reconstructive surgery. The aim of the present study was 3D reconstruction of the human ear with cadaveric ear cartilages seeded with human mesenchymal stem cells. We used cadaveric ear cartilages with preserved perichondrium. The samples were divided into 2 groups: group A (cartilage alone) and group B (cartilage seeded with a mixture of fibrin powder and mesenchymal stem cell [1,000,000 cells/cm] used and implanted in back of 10 athymic rats). After 12 weeks, the cartilages were removed and shape, size, weight, flexibility, and chondrocyte viability were evaluated. P value <0.05 was considered significant. In group A, size and weight of cartilages clearly reduced (P < 0.05) and then shape and flexibility (torsion of cartilages in clockwise and counterclockwise directions) were evaluated, which were found to be significantly reduced (P > 0.05). After staining with hematoxylin and eosin and performing microscopic examination, very few live chondrocytes were found in group A. In group B, size and weight of samples were not changed (P < 0.05); the shape and flexibility of samples were well maintained (P < 0.05) and on performing microscopic examination of cartilage samples, many live chondrocytes were found in cartilage (15-20 chondrocytes in each microscopic field). In samples with human stem cell, all variables (size, shape, weight, and flexibility) were significantly maintained and abundant live chondrocytes were found on performing microscopic examination. This method may be used for reconstruction of full defect of auricles in humans.

  2. Dissolved oxygen as a key parameter to aerobic granule formation.

    PubMed

    Sturm, B S McSwain; Irvine, R L

    2008-01-01

    Much research has asserted that high shear forces are necessary for the formation of aerobic granular sludge in Sequencing Batch Reactors (SBRs). In order to distinguish the role of shear and dissolved oxygen on granule formation, two separate experiments were conducted with three bench-scale SBRs. In the first experiment, an SBR was operated with five sequentially decreasing superficial upflow gas velocities ranging from 1.2 to 0.4 cm s(-1). When less than 1 cm s(-1) shear was applied to the reactor, aerobic granules disintegrated into flocs, with corresponding increases in SVI and effluent suspended solids. However, the dissolved oxygen also decreased from 8 mg L(-1) to 5 mg L(-1), affecting the Feast/Famine regime in the SBR and the substrate removal kinetics. A second experiment operated two SBRs with an identical shear force of 1.2 cm s(-1), but two dissolved oxygen concentrations. Even when supplied a high shear force, aerobic granules could not form at a dissolved oxygen less than 5 mg L(-1), with a Static Fill. These results indicate that the substrate removal kinetics and dissolved oxygen are more significant to granule formation than shear force. Copyright IWA Publishing 2008.

  3. Unified treatment of microscopic boundary conditions and efficient algorithms for estimating tangent operators of the homogenized behavior in the computational homogenization method

    NASA Astrophysics Data System (ADS)

    Nguyen, Van-Dung; Wu, Ling; Noels, Ludovic

    2017-03-01

    This work provides a unified treatment of arbitrary kinds of microscopic boundary conditions usually considered in the multi-scale computational homogenization method for nonlinear multi-physics problems. An efficient procedure is developed to enforce the multi-point linear constraints arising from the microscopic boundary condition either by the direct constraint elimination or by the Lagrange multiplier elimination methods. The macroscopic tangent operators are computed in an efficient way from a multiple right hand sides linear system whose left hand side matrix is the stiffness matrix of the microscopic linearized system at the converged solution. The number of vectors at the right hand side is equal to the number of the macroscopic kinematic variables used to formulate the microscopic boundary condition. As the resolution of the microscopic linearized system often follows a direct factorization procedure, the computation of the macroscopic tangent operators is then performed using this factorized matrix at a reduced computational time.

  4. Primary Renal Sarcomas in the Intergroup Rhabdomyosarcoma Study Group (IRSG) Experience, 1972–2005: A Report from the Children’s Oncology Group

    PubMed Central

    Raney, Beverly; Anderson, James; Arndt, Carola; Crist, Willam; Maurer, Harold; Qualman, Stephen; Wharam, Moody; Meyer, William

    2009-01-01

    Purpose To describe clinical and pathologic characteristics and outcome of patients with renal sarcomas. Patients/Methods The IRSG database includes newly diagnosed patients <21 years old with rhabdomyosarcoma (RMS) or undifferentiated sarcoma (UDS). We identified patients with renal sarcoma and reviewed their charts. Results Ten of the 5,746 eligible IRSG patients enrolled from 1972–2005 had primary renal embryonal RMS (N=6) or UDS (N=4). Anaplasia was present in six (60%) of the tumors. Patients’ ages ranged from 2.6–17.8 years. Tumor diameters ranged from 7–15 cm (median, 12 cm). At diagnosis, seven patients had localized disease: four underwent complete removal of tumor (Group I), two had microscopic residual (Group II), and one had gross residual tumor (Group III). Three patients had distant metastases (Group IV) in lungs and bone. Nine patients received vincristine, actinomycin D and cyclophosphamide (VAC). Two Group I patients received no radiation therapy (XRT); others received XRT to the primary tumor and to some metastatic sites. Nine patients achieved complete disappearance of tumor, six due to the initial operation. Tumors recurred in lung (N=2) or brain (N=1) in Group IV patients; each died within 16 months. The Group III patient died of Aspergillus pneumonia. The six Group I and II patients survive, continuously disease-free, at 2.7 to 17.3 years (median, 4.7 years). Conclusions Patients with renal sarcomas often present with large tumors, many of them containing anaplastic features. Removing all gross disease at diagnosis, if feasible, is a critical component of treatment to curing patients with renal sarcoma. PMID:18523987

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Li; Zhu, Zihua; Yu, Xiao-Ying

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a unique surface analysis technique because it can provide molecular recognition for organic and biological molecules. However, analyzing aqueous solution surfaces by ToF-SIMS is difficult, because ToF-SIMS is a high-vacuum technique, while the vapor pressure of water is about 2.3 kPa at room temperature (20 C). We designed and fabricated a self-contained microfluidic device, enabling in situ analysis of aqueous surfaces by scanning electron microscope (SEM) and ToF-SIMS, which has been briefly reported.1,2 In this study, we report more performance data, focusing on the performance of this device for in situ analysis ofmore » organic molecules at aqueous surfaces using ToF-SIMS. Three representative organic compounds (formic acid, glycerol, and glutamic acid) were tested, and their molecular signals were successfully observed. The device can be self-running in vacuum for 8 hours, and SIMS measurements are feasible at any time in this time range. The stability of this device under primary ion beam bombardment is also impressive. High fluence (6 × 1012 ions cm-2 s-1) measurements can be operated continuously for up to 30 minutes without any significant damage to the aperture. However, extra-high fluence measurements (>1 × 1014 ions cm-2 s-1) may lead to liquid bumping in the aperture, and the aqueous solutions may spread out quickly. Signal reproducibility is reasonably good, and relative standard deviation (RSD) for molecular ion signals can be controlled to be smaller than ±15% for consecutive measurements. Measurements at long time intervals (e.g., 60 min) show RSDs of ±40-50%. In addition, the detection limits of formic acid, glycerol, and glutamic acid are estimated to be 0.04%, 0.008%, and 0.002% (weight ratio), respectively.« less

  6. A useful method for assessing differences of compensatory hypertrophy in the contralateral kidney before and after radical nephrectomy in patients with renal cell carcinoma: ellipsoid formula on computed tomography.

    PubMed

    Park, Bong Hee; Cho, Kang Jun; Kim, Jung Im; Bae, Sang Rak; Lee, Yong Seok; Kang, Sung Hak; Kim, Joon Chul; Han, Chang Hee

    2018-02-01

    To investigate the usefulness of the ellipsoid formula for assessing compensatory hypertrophy of the contralateral kidney on pre-operative and post-operative CT in renal cell carcinoma (RCC) patients. We retrospectively identified 389 patients who had radical nephrectomy for RCC between 2011  and 2015. Contrast-enhanced CT was performed within 3 months pre-operative and at 1 year post-operative. The kidney volumes were calculated from CT using the ellipsoid formula. We subdivided patients into three groups based on tumour size (I: ≤4 cm, II: 4-7 cm, III: >7 cm). Volumetric renal parameters were compared and multivariate analyses were performed to determine predictors associated with pre-operative  and post-operative compensatory hypertrophy. Kidney volume calculation using the ellipsoid  method took a median of 51 s. Group III had a significantly larger median pre-operative contralateral renal volume than Groups I and II (I:  140.4, II: 141.6, III: 166.7 ml, p < 0.05). However, the median ratio of post-operative contralateral renal volume change was significantly higher in Groups I and II than Group III (I: 0.36, II: 0.23, III: 0.12, p < 0.001). On multivariate analysis, tumour size revealed the strongest positive association with pre-operative contralateral kidney volume (partial regression coefficient: β = 30.8, >7 cm) and ratio of post-operative contralateral kidney volume change (β  = 0.214, I vs III; β = 0.168, II vs III). Kidney volume calculation for assessing pre- and post-operative compensatory hypertrophy of the contralateral kidney in RCC patients can be easily and rapidly performed from CT images using the ellipsoid formula. Advances in knowledge: The ellipsoid formula allows reliable method for assessing pre-operative and post-operative compensatory hypertrophy of the contralateral kidney in RCC.

  7. Macroscopic and microscopic analysis of the tongue of the common opossum (Didelphis marsupialis).

    PubMed

    Mançanares, Celina A F; Santos, Amilton C; Piemonte, Maria V; Vasconcelos, Bruno G; Carvalho, Ana F; Miglino, Maria A; Ambrósio, Carlos E; Assis Neto, Antônio C

    2012-10-01

    We performed a macroscopic and microscopic study of the tongues of common opossums, Didelphis marsupialis, from South America. We studied two males and two females. We collected morphometric data on the tongue with precision calipers. For the light microscopy and scanning electron microscopy analyses, we fixed tissue fragments in 10% formaldehyde and 2.5% glutaraldehyde, respectively. The opossum tongues averaged 5.87 ± 0.20 cm in length, 3.27 ± 0.15 cm in width at the lingual body, and 3.82 ± 0.15 cm in width at the root. The mean thickness of the lingual body was 1.8 ± 0.1 cm, and the thickness of the root was 3.82 ± 0.15 cm. Sharp filiform papillae were scattered across the entire tongue; conical filiform papillae occurred on the lingual body and tongue tip; fungiform papillae were scattered among the filiform papillae on the lingual body and tongue tip; and there were three vallate papillae at the root of the tongue. We found two strands of papillary projections in the tongue root. Despite the low variability observed in the lingual papillae, the morphological data obtained in this study may be related to the opossum's diverse food habits and the extensive geographic distribution of the species throughout America. Copyright © 2012 Wiley Periodicals, Inc.

  8. The X-ray microscopy beamline UE46-PGM2 at BESSY

    NASA Astrophysics Data System (ADS)

    Follath, R.; Schmidt, J. S.; Weigand, M.; Fauth, K.

    2010-06-01

    The Max Planck Institute for Metal Physics in Stuttgart and the Helmholtz Center Berlin operate a soft X-ray microscopy beamline at the storage ring BESSY II. A collimated PGM serves as monochromator for a scanning X-ray microscope and a full field X-ray microscope at the helical undulator UE46. The selection between both instruments is accomplished via two switchable focusing mirrors. The scanning microscope (SM) is based on the ALS STXM microscope and fabricated by the ACCEL company. The full field microscope (FFM) is currently in operation at the U41-SGM beamline and will be relocated to its final location this year.

  9. Novel GO-LaSmO2 Nanocomposite as an Effective Electrode Material for Hydrogen Fuel Cells

    NASA Astrophysics Data System (ADS)

    El-Amin, Ayman A.; Othman, Abdelhameed M.

    2016-04-01

    Nano-composites of lanthanum-samarium oxide (LaSmO2) were prepared in the absence and presence of graphene oxide (GO) and characterized as an effective electrode material for hydrogen fuel cells. X-ray and scanning electron microscope investigations revealed grain sizes of 8 nm for LaSmO2 and 12 nm for GO-LaSmO2 composites. The x-ray diffraction pattern showed sharp peaks, indicating a well-crystallized phase indexable to a rhombohedral structure with space group R 3 C , and their structural refinement performed in the hexagonal mode. The ionic conductivity of LaSmO2 was found to be 4.12 × 10-5 S/cm, while in the presence of GO it was enhanced to 5.32 × 10-5 S/cm. The mechanism of conduction in the proposed nano-materials was investigated based on frequency exponent S. The values of S were observed to decrease with increasing temperature. This result was found to be in good agreement with the correlated barrier hopping (CBH) model. The present work revealed GO to be a conductivity enhancer that caused the GO-LaSmO2 composite to be an effective electrode material for hydrogen fuel cells.

  10. Osteoporosis-pseudoglioma syndrome, a disorder affecting skeletal strength and vision, is assigned to chromosome region 11q12-13

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Yaoqin; Liu, Jin; Warman, M.L.

    Osteoporosis-pseudoglioma syndrome (OPS) is an autosomal recessive disorder characterized by severe juvenile-onset osteoporosis and congenital or juvenile-onset blindness. The pathogenic mechanism is not known. Clinical, biochemical, and microscopic analyses suggest that OPS may be a disorder of matrix homeostasis rather than a disorder of matrix structure. Consequently, identification of the OPS gene and its protein product could provide insights regarding common osteoporotic conditions, such as postmenopausal and senile osteoporosis. As a first step toward determining the cause of OPS, we utilized a combination of traditional linkage analysis and homozygosity mapping to assign the OPS locus to chromosome region 11q12-13. Mappingmore » was accomplished by analyzing 16 DNA samples (seven affected individuals) from three different consanguineous kindreds. Studies in 10 additional families narrowed the candidate region, supported locus homogeneity, and did not detect founder effects. The OPS locus maps to a 13-cM interval between D11S1298 and D11S971 and most likely lies in a 3-cM region between GSTP1 and D11S1296. At present, no strong candidate genes colocalize with OPS. 33 refs., 2 figs., 1 tab.« less

  11. Automatic Focus Adjustment of a Microscope

    NASA Technical Reports Server (NTRS)

    Huntsberger, Terrance

    2005-01-01

    AUTOFOCUS is a computer program for use in a control system that automatically adjusts the position of an instrument arm that carries a microscope equipped with an electronic camera. In the original intended application of AUTOFOCUS, the imaging microscope would be carried by an exploratory robotic vehicle on a remote planet, but AUTOFOCUS could also be adapted to similar applications on Earth. Initially control software other than AUTOFOCUS brings the microscope to a position above a target to be imaged. Then the instrument arm is moved to lower the microscope toward the target: nominally, the target is approached from a starting distance of 3 cm in 10 steps of 3 mm each. After each step, the image in the camera is subjected to a wavelet transform, which is used to evaluate the texture in the image at multiple scales to determine whether and by how much the microscope is approaching focus. A focus measure is derived from the transform and used to guide the arm to bring the microscope to the focal height. When the analysis reveals that the microscope is in focus, image data are recorded and transmitted.

  12. Biofilm-Forming Abilities of Listeria monocytogenes Serotypes Isolated from Different Sources

    PubMed Central

    Doijad, Swapnil P.; Barbuddhe, Sukhadeo B.; Garg, Sandeep; Poharkar, Krupali V.; Kalorey, Dewanand R.; Kurkure, Nitin V.; Rawool, Deepak B.; Chakraborty, Trinad

    2015-01-01

    A total of 98 previously characterized and serotyped L. monocytogenes strains, comprising 32 of 1/2a; 20 of 1/2b and 46 of 4b serotype, from clinical and food sources were studied for their capability to form a biofilm. The microtiter plate assay revealed 62 (63.26%) strains as weak, 27 (27.55%) strains as moderate, and 9 (9.18%) strains as strong biofilm formers. Among the strong biofilm formers, 6 strains were of serotype 1/2a and 3 strains were of serotype 1/2b. None of the strain from 4b serotype exhibited strong biofilm formation. No firm correlation (p = 0.015) was noticed between any serotype and respective biofilm formation ability. Electron microscopic studies showed that strong biofilm forming isolates could synthesize a biofilm within 24 h on surfaces important in food industries such as stainless steel, ceramic tiles, high-density polyethylene plastics, polyvinyl chloride pipes, and glass. Cell enumeration of strong, moderate, and weak biofilm was performed to determine if the number of cells correlated with the biofilm-forming capabilities of the isolates. Strong, moderate, and weak biofilm showed 570±127× 103 cells/cm2, 33±26× 103 cells/cm2, 5±3× 103 cells/cm2, respectively, indicating that the number of cells was directly proportional to the strength of the biofilm. The hydrophobicity index (HI) analysis revealed higher hydrophobicity with an increased biofilm formation. Fatty acid methyl esterase analysis revealed the amount of certain fatty acids such as iso-C15:0, anteiso-C15:0, and anteiso-C17:0 fatty acids correlated with the biofilm-forming capability of L. monocytogenes. This study showed that different strains of L. monocytogenes form biofilm of different intensities which did not completely correlate with their serotype; however, it correlated with the number of cells, hydrophobicity, and amount of certain fatty acids. PMID:26360831

  13. Endoscopic vs. microscopic transsphenoidal surgery for Cushing's disease: a systematic review and meta-analysis.

    PubMed

    Broersen, Leonie H A; Biermasz, Nienke R; van Furth, Wouter R; de Vries, Friso; Verstegen, Marco J T; Dekkers, Olaf M; Pereira, Alberto M

    2018-05-16

    Systematic review and meta-analysis comparing endoscopic and microscopic transsphenoidal surgery for Cushing's disease regarding surgical outcomes (remission, recurrence, and mortality) and complication rates. To stratify the results by tumor size. Nine electronic databases were searched in February 2017 to identify potentially relevant articles. Cohort studies assessing surgical outcomes or complication rates after endoscopic or microscopic transsphenoidal surgery for Cushing's disease were eligible. Pooled proportions were reported including 95% confidence intervals. We included 97 articles with 6695 patients in total (5711 microscopically and 984 endoscopically operated). Overall, remission was achieved in 5177 patients (80%), with no clear difference between both techniques. Recurrence was around 10% and short term mortality < 0.5% for both techniques. Cerebrospinal fluid leak occurred more often in endoscopic surgery (12.9 vs. 4.0%), whereas transient diabetes insipidus occurred less often (11.3 vs. 21.7%). For microadenomas, results were comparable between both techniques. For macroadenomas, the percentage of patients in remission was higher after endoscopic surgery (76.3 vs. 59.9%), and the percentage recurrence lower after endoscopic surgery (1.5 vs. 17.0%). Endoscopic surgery for patients with Cushing's disease reaches comparable results for microadenomas, and probably better results for macroadenomas than microscopic surgery. This is present despite the presumed learning curve of the newer endoscopic technique, although confounding cannot be excluded. Based on this study, endoscopic surgery may thus be considered the current standard of care. Microscopic surgery can be used based on neurosurgeon's preference. Endocrinologists and neurosurgeons in pituitary centers performing the microscopic technique should at least consider referring Cushing's disease patients with a macroadenoma.

  14. Dental enamel defect diagnosis through different technology-based devices.

    PubMed

    Kobayashi, Tatiana Yuriko; Vitor, Luciana Lourenço Ribeiro; Carrara, Cleide Felício Carvalho; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Oliveira, Thais Marchini

    2018-06-01

    Dental enamel defects (DEDs) are faulty or deficient enamel formations of primary and permanent teeth. Changes during tooth development result in hypoplasia (a quantitative defect) and/or hypomineralisation (a qualitative defect). To compare technology-based diagnostic methods for detecting DEDs. Two-hundred and nine dental surfaces of anterior permanent teeth were selected in patients, 6-11 years of age, with cleft lip with/without cleft palate. First, a conventional clinical examination was conducted according to the modified Developmental Defects of Enamel Index (DDE Index). Dental surfaces were evaluated using an operating microscope and a fluorescence-based device. Interexaminer reproducibility was determined using the kappa test. To compare groups, McNemar's test was used. Cramer's V test was used for comparing the distribution of index codes obtained after classification of all dental surfaces. Cramer's V test revealed statistically significant differences (P < .0001) in the distribution of index codes obtained using the different methods; the coefficients were 0.365 for conventional clinical examination versus fluorescence, 0.961 for conventional clinical examination versus operating microscope and 0.358 for operating microscope versus fluorescence. The sensitivity of the operating microscope and fluorescence method was statistically significant (P = .008 and P < .0001, respectively). Otherwise, the results did not show statistically significant differences in accuracy and specificity for either the operating microscope or the fluorescence methods. This study suggests that the operating microscope performed better than the fluorescence-based device and could be an auxiliary method for the detection of DEDs. © 2017 FDI World Dental Federation.

  15. Sunrise-driven movements of dust on the Moon: Apollo 12 Ground-truth measurements

    NASA Astrophysics Data System (ADS)

    O'Brien, Brian J.; Hollick, Monique

    2015-12-01

    The first sunrise after Apollo 12 astronauts left the Moon caused dust storms across the site where rocket exhausts had disrupted about 2000 kg of smooth fine dust. The next few sunrises started progressively weaker dust storms, and the Eastern horizon brightened, adding to direct sunlight for half an hour. These Ground truth measurements were made 100 cm above the surface by the 270 g Apollo 12 Dust Detector Experiment we invented in 1966. Dust deposited on the horizontal solar cell during two lunar days after the first sunrise was almost 30% of the total it then measured over 6 years. The vertical east-facing solar cell measured horizon brightening on 14 of the first 17 lunations, with none detected on the following 61 Lunar Days. Based on over 2 million such measurements we propose a new qualitative model of sunrise-driven transport of individual dust particles freed by Apollo 12 activities from strong particle-to-particle cohesive forces. Each sunrise caused sudden surface charging which, during the first few hours, freshly mobilised and lofted the dust remaining free, microscopically smoothing the disrupted local areas. Evidence of reliability of measurements includes consistency among all 6 sensors in measurements throughout an eclipse. We caution Google Lunar XPrize competitors and others planning missions to the Moon and large airless asteroids that, after a spacecraft lands, dust hazards may occur after each of the first few sunrises. Mechanical problems in its first such period stranded Chinese lunar rover Yutu in 2014, although we would not claim yet that the causes were dust. On the other hand, sunrise-driven microscopic smoothing of disturbed areas may offer regular natural mitigations of dust consequences of mining lunar resources and reduce fears that many expeditions might cause excessive fine dust globally around the Moon.

  16. Microsurgical Clipping of an Anterior Communicating Artery Aneurysm Using a Novel Robotic Visualization Tool in Lieu of the Binocular Operating Microscope: Operative Video.

    PubMed

    Klinger, Daniel R; Reinard, Kevin A; Ajayi, Olaide O; Delashaw, Johnny B

    2018-01-01

    The binocular operating microscope has been the visualization instrument of choice for microsurgical clipping of intracranial aneurysms for many decades. To discuss recent technological advances that have provided novel visualization tools, which may prove to be superior to the binocular operating microscope in many regards. We present an operative video and our operative experience with the BrightMatterTM Servo System (Synaptive Medical, Toronto, Ontario, Canada) during the microsurgical clipping of an anterior communicating artery aneurysm. To the best of our knowledge, the use of this device for the microsurgical clipping of an intracranial aneurysm has never been described in the literature. The BrightMatterTM Servo System (Synaptive Medical) is a surgical exoscope which avoids many of the ergonomic constraints of the binocular operating microscope, but is associated with a steep learning curve. The BrightMatterTM Servo System (Synaptive Medical) is a maneuverable surgical exoscope that is positioned with a directional aiming device and a surgeon-controlled foot pedal. While utilizing this device comes with a steep learning curve typical of any new technology, the BrightMatterTM Servo System (Synaptive Medical) has several advantages over the conventional surgical microscope, which include a relatively unobstructed surgical field, provision of high-definition images, and visualization of difficult angles/trajectories. This device can easily be utilized as a visualization tool for a variety of cranial and spinal procedures in lieu of the binocular operating microscope. We anticipate that this technology will soon become an integral part of the neurosurgeon's armamentarium. Copyright © 2017 by the Congress of Neurological Surgeons

  17. Liquid–Liquid Mixing Studies in Annular Centrifugal Contactors Comparing Stationary Mixing Vane Options

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wardle, Kent E.

    2015-11-10

    Comparative studies of multiphase operation of annular centrifugal contactors showing the impact of housing stationary mixing vane configuration. A number of experimental results for several different mixing vane options are reported with selected measurements in a lab-scale 5 cm contactor and 12.5 cm engineering-scale unit. Fewer straight vanes give greater mixingzone hold-up compared to curved vanes. Quantitative comparison of droplet size distribution also showed a significant decrease in mean diameter for four straight vanes versus eight curved vanes. This set of measurements gives a compelling case for careful consideration of mixing vane geometry when evaluating hydraulic operation and extraction processmore » efficiency of annular centrifugal contactors.« less

  18. Large scale infrared imaging of tissue micro arrays (TMAs) using a tunable Quantum Cascade Laser (QCL) based microscope.

    PubMed

    Bassan, Paul; Weida, Miles J; Rowlette, Jeremy; Gardner, Peter

    2014-08-21

    Chemical imaging in the field of vibrational spectroscopy is developing into a promising tool to complement digital histopathology. Applications include screening of biopsy tissue via automated recognition of tissue/cell type and disease state based on the chemical information from the spectrum. For integration into clinical practice, data acquisition needs to be speeded up to implement a rack based system where specimens are rapidly imaged to compete with current visible scanners where 100's of slides can be scanned overnight. Current Fourier transform infrared (FTIR) imaging with focal plane array (FPA) detectors are currently the state-of-the-art instrumentation for infrared absorption chemical imaging, however recent development in broadly tunable lasers in the mid-IR range is considered the most promising potential candidate for next generation microscopes. In this paper we test a prototype quantum cascade laser (QCL) based spectral imaging microscope with a focus on discrete frequency chemical imaging. We demonstrate how a protein chemical image of the amide I band (1655 cm(-1)) of a 2 × 2.4 cm(2) breast tissue microarray (TMA) containing over 200 cores can be measured in 9 min. This result indicates that applications requiring chemical images from a few key wavelengths would be ideally served by laser-based microscopes.

  19. Comparison of skin responses from macroscopic and microscopic UV challenges

    NASA Astrophysics Data System (ADS)

    Seo, InSeok; Bargo, Paulo R.; Chu, Melissa; Ruvolo, Eduardo; Kollias, Nikiforos

    2011-03-01

    The minimal erythema dose induced by solar-simulated radiation is a useful measure of UV sensitivity of skin. Most skin phototests have been conducted by projecting a flat field of UV radiation onto the skin in an area greater than 15 cm × 15 cm with an increment of radiation doses. In this study, we investigated the responses of human skin to solar-simulated radiation of different field sizes. Twelve human subjects of skin phototype I-IV were exposed to solar-simulated radiation (SSR) on their upper inner arm or on their lower back with a series of doses in increments of 20% in order to determine the threshold dose to induce a minimal perceptible erythema response (MED). Each dose was delivered with a liquid light guide (8 mm diameter on the back or 6 mm on the upper inner arm) and with quartz optical fibers of 200 μm diameter. The resulting skin responses were evaluated visually and investigated with a reflectance confocal microscope and imaging. The erythema response to the microscopic challenge was always diffuse with no clear boundaries extending to several times the exposed site diameter at doses greater than 2 MED. The skin returned to normal appearance from the microscopic challenge after two weeks of exposure while change in appearance for the larger areas persisted for several weeks to months. This new modality of testing provides the possibility to study skin at the microscopic level with a rapid recovery following challenge.

  20. A case of incarcerated umbilical hernia in an adult treated by laparoscopic surgery

    PubMed Central

    Tsushimi, Takaaki; Mori, Hirohito; Nagase, Takashi; Harada, Takasuke; Ikeda, Yoshitaka

    2015-01-01

    A 42-year-old, obese woman was admitted to our hospital 3 h after the sudden development of abdominal pain. Her umbilical region was swollen and she was diagnosed with incarceration of an umbilical hernia by computed tomography. Although we tried, we were unable to reduce the hernia with a manipulative procedure. We decided to perform an emergency laparoscopy. Once general anesthesia was induced, we achieved hernia reduction. From a laparoscopic view, the portion of strangulated small intestine was neither necrotic nor perforated. The size of the hernial orifice was ∼2 × 2 cm, and thus, we selected a 12 × 12 cm composite mesh to cover the hernia defect by at least 5 cm in all directions. The surgical procedure was uneventful and the total operation time was 112 min. The patient recovered uneventfully and was discharged on postoperative day 9. She remains free of recurrence 20 months after surgery. PMID:25672973

  1. Curiosity's Mars Hand Lens Imager (MAHLI): Inital Observations and Activities

    NASA Technical Reports Server (NTRS)

    Edgett, K. S.; Yingst, R. A.; Minitti, M. E.; Robinson, M. L.; Kennedy, M. R.; Lipkaman, L. J.; Jensen, E. H.; Anderson, R. C.; Bean, K. M.; Beegle, L. W.; hide

    2013-01-01

    MAHLI (Mars Hand Lens Imager) is a 2-megapixel focusable macro lens color camera on the turret on Curiosity's robotic arm. The investigation centers on stratigraphy, grain-scale texture, structure, mineralogy, and morphology of geologic materials at Curiosity's Gale robotic field site. MAHLI acquires focused images at working distances of 2.1 cm to infinity; for reference, at 2.1 cm the scale is 14 microns/pixel; at 6.9 cm it is 31 microns/pixel, like the Spirit and Opportunity Microscopic Imager (MI) cameras.

  2. The Atomic Force Microscopic (AFM) Characterization of Nanomaterials

    DTIC Science & Technology

    2009-06-01

    Several Types of Microscopes ..................................................................................................7 8 OM on Mica Surface...12 9 AFM on Mica Surface...12 10 OM Images SWNTs on Mica After 1) 30 Minutes, b) 60

  3. [Prevention of side effects and complications after operation for partial ileal bypass].

    PubMed

    Mirchuk, K K; Sedletskiĭ, Iu I

    2014-01-01

    Side effects and complications of the application of partial ileal bypass used for dislipidemia were analyzed in 162 patients with atherosclerosis. It was shown, that the partial ileal bypass operation could lead to the development of series of undesirable side effects such as diarrhea, hypovitaminosis B12, off-state intestine enteritis. The application of modification of partial ileal bypass such as formation of ileo-ileoanastomosis 5-6 cm long near ileocecal valve with the maintenance of its functions disposed the diarrhea and minimized the risk of the development of hypovitaminosis B12 after operation. It is possible to prevent the development of enteritis of off-state loop of the small intestine by using microanastomosis between off-state and functioning iliac intestine. The partial ileal bypass operation didn't influence on body weight, wouldn't increase the risk of stone formation in the gallbladder and kidneys. The risk of the development of hypovitaminosis B12 is minimal after operation.

  4. Performance of a catalytic reactor at simulated gas turbine combustor operating conditions

    NASA Technical Reports Server (NTRS)

    Anderson, D. N.; Tacina, R. R.; Mroz, T. S.

    1975-01-01

    The performance of a catalytic reactor 12 cm in diameter and 17 cm long was evaluated at simulated gas turbine combustor operating conditions using premixed propane and air. Inlet temperatures of 600 and 800 K, pressures of 3 and 6 atm, and reference velocities of 9 to 30 m/s were tested. Data were taken for equivalence ratios as high as 0.43. The operating range was limited on the low-temperature side by very poor efficiency; the minimum exit temperature for good performance ranged from 1400 to 1600 K depending on inlet conditions. As exit temperatures were raised above this minimum, emissions of unburned hydrocarbons decreased, carbon monoxide emissions became generally less than 1 g CO/kg fuel, and nitrogen oxides were less than about 0.1 g NO2/kg fuel.

  5. Various Recrystallizations of CL-20 (HNIW hexanitrohexaazaisowurtzitane).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, Jason Joe

    Impact sensitivity testing was performed using a modified Bureau of Mines (MBOM) impactor manufactured by Safety Management Services, Inc., shown in Figure 1. Type-12 tooling was utilized on this machine with a 2.5kg impactor and matching intermediate mass. This particular machine is capable of a maximum drop height of 115cm with 0.1cm increments, though 1cm increments are typically used. Sample material was placed (35 ± 2mg) onto 1 inch squares of Norton brand 180A Garnet sandpaper. Positive results were detected visually or audibly by the operator as smoke, flash, report, charring/tearing of the sandpaper, etc.

  6. Advantages of using newly developed quartz contact lens with slit illumination from operating microscope.

    PubMed

    Kiyokawa, Masatoshi; Sakuma, Toshiro; Hatano, Noriko; Mizota, Atsushi; Tanaka, Minoru

    2009-06-01

    The purpose of this article is to report the characteristics and advantages of using a newly designed quartz contact lens with slit illumination from an operating microscope for intraocular surgery. The new contact lens is made of quartz. The lens is convex-concave and is used in combination with slit illumination from an operating microscope. The optical properties of quartz make this lens less reflective with greater transmittance. The combination of a quartz contact lens with slit illumination provided a brighter and wider field of view than conventional lenses. This system enabled us to perform bimanual vitrectomy and scleral buckling surgery without indirect ophthalmoscope. Small intraocular structures in the posterior pole or in the periphery were detected more easily. In conclusion, the newly designed quartz lens with slit beam illumination from an operating microscope provided a bright, clear and wide surgical field, and allowed intraocular surgery to be performed more easily.

  7. Micro vs. macrodiscectomy: Does use of the microscope reduce complication rates?

    PubMed

    Murphy, Meghan E; Hakim, Jeffrey S; Kerezoudis, Panagiotis; Alvi, Mohammed Ali; Ubl, Daniel S; Habermann, Elizabeth B; Bydon, Mohamad

    2017-01-01

    A single level discectomy is one of the most common procedures performed by spine surgeons. While some practitioners utilize the microscope, others do not. We postulate improved visualization with an intraoperative microscope decreases complications and inferior outcomes. A multicenter surgical registry was utilized for this retrospective cohort analysis. Patients with degenerative spinal diagnoses undergoing elective single level discectomies from 2010 to 2014 were included. Univariate analysis was performed comparing demographics, patient characteristics, operative data, and outcomes for discectomies performed with and without a microscope. Multivariable logistic regression analysis was then applied to compare outcomes of micro- and macrodiscectomies. Query of the registry yielded 23,583 patients meeting inclusion criteria. On univariate analysis the microscope was used in a greater proportion of the oldest age group as well as Hispanic white patients. Patients with any functional dependency, history of congestive heart failure, chronic corticosteroid use, or anemia (hematocrit<35%) also had greater proportions of microdiscectomies. Thoracic region discectomies more frequently involved use of the microscope than cervical or lumbar discectomies (25.0% vs. 16.4% and 13.0%, respectively, p<0.001). Median operative time (IQR) was increased in microscope cases [80min (60, 108) vs. 74min (54, 102), p<0.001]. Of the patients that required reoperation within 30days, 2.5% of them had undergone a microdiscectomy compared to 1.9% who had undergone a macrodiscectomy, p=0.044. On multivariable analysis, microdiscectomies were more likely to have an operative time in the top quartile of discectomy operative times, ≥103min (OR 1.256, 95% CI 1.151-1.371, p<0.001). In regards to other multivariable outcome models for any complication, surgical site infection, dural tears, reoperation, and readmission, no significant association with microdiscectomy was found. The use of the microscope was found to significantly increase the odds of longer operative time, but not influence rates of postoperative complications. Thus, without evidence from this study that the microscope decreases complications, the use of the microscope should be at the surgeon's discretion, validating the use of both macro and micro approaches to discectomy as acceptable standards of care. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Clinical microscopic analysis of ProTaper retreatment system efficacy considering root canal thirds using three endodontic sealers.

    PubMed

    Só, Marcus Vinícius Reis; De Figueiredo, Jose Antônio Poli; Freitas Fachin, Elaine Vianna; Húngaro Duarte, Marco Antônio; Pereira, Jefferson Ricardo; Kuga, Milton Carlos; Da Rosa, Ricardo Abreu

    2012-09-01

    To evaluate the efficacy of ProTaper Universal rotary retreatment system and the influence of sealer type on the presence of filling debris in the reinstrumented canals viewed in an operative clinical microscope. Forty-five palatal root canals of first molars were filled with gutta-percha and one of the following sealers: G1, EndoFill; G2, AH Plus; G3, Sealapex. The canals were then reinstrumented with ProTaper Universal rotary system. Roots were longitudinally sectioned and examined under an operative clinical microscope (10×), and the amount of filling debris on canal walls was analyzed using the AutoCAD 2004 software. A single operator used a specific software tool to outline the canal area and the filling debris area in each third (cervical, middle, and apical), as well as the total canal area. Data were analyzed by Kruskal-Wallis test and Tukey test at P < 0.05. Sealapex demonstrated significant differences in the average of filling debris area/canal among the 3 thirds. This group revealed that apical third showed more debris than the both cervical and middle third (P < 0.0001). Endofill presented significantly more filling debris than Sealapex in the cervical third (P < 0.05). In the middle (P = 0.12) and apical third (P = 0.10), there were no differences amongst groups. Debris was left in all canal thirds, regardless of the retreatment technique. The greatest differences between techniques and sealers were found in the cervical third. Copyright © 2012 Wiley Periodicals, Inc.

  9. Microscopic Analysis of Activated Sludge. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on the use of a compound microscope to analyze microscope communities, present in wastewater treatment processes, for operational control. Course topics include: sampling techniques, sample handling, laboratory analysis, identification of organisms, data interpretation, and use of the compound microscope.…

  10. A sub-cm micromachined electron microscope

    NASA Technical Reports Server (NTRS)

    Feinerman, A. D.; Crewe, D. A.; Perng, D. C.; Shoaf, S. E.; Crewe, A. V.

    1993-01-01

    A new approach for fabricating macroscopic (approximately 10x10x10 mm(exp 3)) structures with micron accuracy has been developed. This approach combines the precision of semiconductor processing and fiber optic technologies. A (100) silicon wafer is anisotropically etched to create four orthogonal v-grooves and an aperture on each 10x12 mm die. Precision 308 micron optical fibers are sandwiched between the die to align the v-grooves. The fiber is then anodically bonded to the die above and below it. This procedure is repeated to create thick structures and a stack of 5 or 6 die will be used to create a miniature scanning electron microscope (MSEM). Two die in the structure will have a segmented electrode to deflect the beam and correct for astigmatism. The entire structure is UHV compatible. The performance of an SEM improves as its length is reduced and a sub-cm 2 keV MSEM with a field emission source should have approximately 1 nm resolution. A low voltage high resolution MSEM would be useful for the examination of biological specimens and semiconductors with a minimum of damage. The first MSEM will be tested with existing 6 micron thermionic sources. In the future a micromachined field emission source will be used. The stacking technology presented in this paper can produce an array of MSEMs 1 to 30 mm in length with a 1 mm or larger period. A key question being addressed by this research is the optimum size for a low voltage MSEM which will be determined by the required spatial resolution, field of view, and working distance.

  11. Feasibility of Telementoring for Microneurosurgical Procedures Using a Microscope: A Proof-of-Concept Study.

    PubMed

    Ladd, Bryan M; Tackla, Ryan D; Gupte, Akshay; Darrow, David; Sorenson, Jeffery; Zuccarello, Mario; Grande, Andrew W

    2017-03-01

    Our pilot study evaluated the effectiveness of our telementoring-telescripting model to facilitate seamless communication between surgeons while the operating surgeon is using a microscope. As a first proof of concept, 4 students identified 20 anatomic landmarks on a dry human skull with or without telementoring guidance. To assess the ability to communicate operative information, a senior neurosurgery resident evaluated the student's ability and timing to complete a stepwise craniotomy on a cadaveric head, with and without telementoring guidance; a second portion included exposure of the anterior circulation. The mentor was able to annotate directly onto the operator's visual field, which was visible to the operator without looking away from the binocular view. The students showed that they were familiar with half (50% ± 10%) of the structures for identification and none was familiar with the steps to complete a craniotomy before using our system. With the guidance of a remote surgeon projected into the visual field of the microscope, the students were able to correctly identify 100% of the structures and complete a craniotomy. Our system also proved effective in guiding a more experienced neurosurgery resident through complex operative steps associated with exposure of the anterior circulation. Our pilot study showed a platform feasible in providing effective operative direction to inexperienced operators while operating using a microscope. A remote mentor was able to view the visual field of the microscope, annotate on the visual stream, and have the annotated stream appear in the binocular view for the operating mentee. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. An apparatus for studying electrical breakdown in liquid helium at 0.4 K and testing electrode materials for the neutron electric dipole moment experiment at the Spallation Neutron Source

    DOE PAGES

    Ito, T. M.; Ramsey, J. C.; Yao, W.; ...

    2016-04-25

    In this study, we have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and ~600 Torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of 1–2 cm between them, and a potential up to ±50 kV can be applied to each electrode. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes 12 cm in diameter for a widemore » range of pressures at 0.4 K. We also measured the current between two electrodes. Our initial results, I < 1 pA at 45 kV, correspond to a lower bound on the effective volume resistivity of liquid helium of ρ V > 5 × 10 18 Ω cm. This lower bound is 5 times larger than the bound previously measured. Finally, we report the design, construction, and operational experience of the apparatus, as well as initial results« less

  13. Laser selective cutting of biological tissues by impulsive heat deposition through ultrafast vibrational excitations.

    PubMed

    Franjic, Kresimir; Cowan, Michael L; Kraemer, Darren; Miller, R J Dwayne

    2009-12-07

    Mechanical and thermodynamic responses of biomaterials after impulsive heat deposition through vibrational excitations (IHDVE) are investigated and discussed. Specifically, we demonstrate highly efficient ablation of healthy tooth enamel using 55 ps infrared laser pulses tuned to the vibrational transition of interstitial water and hydroxyapatite around 2.95 microm. The peak intensity at 13 GW/cm(2) was well below the plasma generation threshold and the applied fluence 0.75 J/cm(2) was significantly smaller than the typical ablation thresholds observed with nanosecond and microsecond pulses from Er:YAG lasers operating at the same wavelength. The ablation was performed without adding any superficial water layer at the enamel surface. The total energy deposited per ablated volume was several times smaller than previously reported for non-resonant ultrafast plasma driven ablation with similar pulse durations. No micro-cracking of the ablated surface was observed with a scanning electron microscope. The highly efficient ablation is attributed to an enhanced photomechanical effect due to ultrafast vibrational relaxation into heat and the scattering of powerful ultrafast acoustic transients with random phases off the mesoscopic heterogeneous tissue structures.

  14. High-performance PbS quantum dot vertical field-effect phototransistor using graphene as a transparent electrode

    NASA Astrophysics Data System (ADS)

    Che, Yongli; Zhang, Yating; Cao, Xiaolong; Song, Xiaoxian; Zhang, Haiting; Cao, Mingxuan; Dai, Haitao; Yang, Junbo; Zhang, Guizhong; Yao, Jianquan

    2016-12-01

    Solution processed photoactive PbS quantum dots (QDs) were used as channel in high-performance near-infrared vertical field-effect phototransistor (VFEpT) where monolayer graphene embedded as transparent electrode. In this vertical architecture, the PbS QD channel was sandwiched and naturally protected between the drain and source electrodes, which made the device ultrashort channel length (110 nm) simply the thickness of the channel layer. The VFEpT exhibited ambipolar operation with high mobilities of μe = 3.5 cm2/V s in n-channel operation and μh = 3.3 cm2/V s in p-channel operation at low operation voltages. By using the photoactive PbS QDs as channel material, the VFEpT exhibited good photoresponse properties with a responsivity of 4.2 × 102 A/W, an external quantum efficiency of 6.4 × 104% and a photodetectivity of 2.1 × 109 Jones at the light irradiance of 36 mW/cm2. Additionally, the VFEpT showed excellent on/off switching with good stability and reproducibility and fast response speed with a short rise time of 12 ms in n-channel operation and 10.6 ms in p-channel operation. These high mobilities, good photoresponse properties and simplistic fabrication of our VFEpTs provided a facile route to the high-performance inorganic photodetectors.

  15. In-situ investigation of laser surface modifications of WC-Co hard metals inside a scanning electron microscope

    NASA Astrophysics Data System (ADS)

    Mueller, H.; Wetzig, K.; Schultrich, B.; Pompe, Wolfgang; Chapliev, N. I.; Konov, Vitaly I.; Pimenov, S. M.; Prokhorov, Alexander M.

    1989-05-01

    The investigation of laser interaction with solid surfaces and of the resulting mechanism of surface modification are of technical interest to optimize technological processes, and they are also of fundamental scientific importance. Most instructive indormation is available with the ail of the in-situ techniques. For instance, measuring of the photon emission of the irradiated surface ane the plasma torch (if it is produced) simultaneously to laser action, makes it possible to gain a global characterization of the laser-solid interaction. In order to obtain additional information about surface and structure modifications in microscopic detail , a laser and scanning electron microscope were combined in to a tandem equipment (LASEM). Inside this eqiipment the microscopic observation is carried out directly at the laser irradiated area without any displacement of the sample. In this way, the stepwise development of surface modification during multipulse irradiation is visible in microscopic details and much more reliable information about the surface modification process is obtainable in comparison to an external laser irradiation. Such kind of equipments were realized simultaneously and independently in the Institut of General Physics (Moscow) and the Central Institute of Solid State Physics and Material Research (Dresden) using a CO2 and a LTd-glass-laser, respectively. In the following the advantages and possibilities of a LASEM shall be demonstrated by some selected investigations of WC-CO hardmeta. The results were obtained in collaboration by both groups with the aid of the pulsed CO2-laser. The TEA CO2 laser was transmitted through a ZnSe-window into the sample chamber of the SEM and focused ofAo tfte sample surface. It was operated in TEM - oo mode with a repetition rate of about 1 pulse per second. A peak power density of about 160 MW/cm2 was achieved in front of the sample surface.

  16. Treatment of pulp and paper industry bleaching effluent by electrocoagulant process.

    PubMed

    Sridhar, R; Sivakumar, V; Prince Immanuel, V; Prakash Maran, J

    2011-02-28

    The experiments were carried out in an electrocoagulation reactor with aluminum as sacrificial electrodes. The influence of electrolysis time, current density, pH, NaCl concentration, rotational speed of the stirrer and electrode distance on reduction of color, COD and BOD were studied in detail. From the experimental results, 15 mA/cm(2) current density, pH of 7, 1 g/l NaCl, 100 rpm, 28°C temperature and 3 cm electrode distance were found to be optimum for maximum reduction of color, COD and BOD. The reduction of color, COD and BOD under the optimum condition were found to be 94%, 90% and 87% respectively. The electrode energy consumption was calculated and found to be varied from 10.1 to 12.9 kWh/m(3) depending on the operating conditions. Under optimal operating condition such as 15 mA/cm(2) current density, pH of 7, 1 g/l NaCl, 100 rpm, 28°C temperature and 3 cm electrode distance, the operating cost was found to be 1.56 US $/m(3). The experimental results proved that the electrocoagulation is a suitable method for treating bleaching plant effluents for reuse. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. High-performance field emission device utilizing vertically aligned carbon nanotubes-based pillar architectures

    NASA Astrophysics Data System (ADS)

    Gupta, Bipin Kumar; Kedawat, Garima; Gangwar, Amit Kumar; Nagpal, Kanika; Kashyap, Pradeep Kumar; Srivastava, Shubhda; Singh, Satbir; Kumar, Pawan; Suryawanshi, Sachin R.; Seo, Deok Min; Tripathi, Prashant; More, Mahendra A.; Srivastava, O. N.; Hahm, Myung Gwan; Late, Dattatray J.

    2018-01-01

    The vertical aligned carbon nanotubes (CNTs)-based pillar architectures were created on laminated silicon oxide/silicon (SiO2/Si) wafer substrate at 775 °C by using water-assisted chemical vapor deposition under low pressure process condition. The lamination was carried out by aluminum (Al, 10.0 nm thickness) as a barrier layer and iron (Fe, 1.5 nm thickness) as a catalyst precursor layer sequentially on a silicon wafer substrate. Scanning electron microscope (SEM) images show that synthesized CNTs are vertically aligned and uniformly distributed with a high density. The CNTs have approximately 2-30 walls with an inner diameter of 3-8 nm. Raman spectrum analysis shows G-band at 1580 cm-1 and D-band at 1340 cm-1. The G-band is higher than D-band, which indicates that CNTs are highly graphitized. The field emission analysis of the CNTs revealed high field emission current density (4mA/cm2 at 1.2V/μm), low turn-on field (0.6 V/μm) and field enhancement factor (6917) with better stability and longer lifetime. Emitter morphology resulting in improved promising field emission performances, which is a crucial factor for the fabrication of pillared shaped vertical aligned CNTs bundles as practical electron sources.

  18. Four canals in the mesial root of a mandibular first molar. A case report under the operating microscope.

    PubMed

    Kontakiotis, Evangelos G; Tzanetakis, Giorgos N

    2007-08-01

    In this era of microscope-assisted endodontics, finding variations in root canal system anatomy is not uncommon. Operating microscopes combined with careful clinical examination and radiographic interpretation can aid the clinician to successfully treat cases with such internal anatomy. The understanding of this view enables the possible location of additional canals in any tooth requiring endodontic treatment. The present clinical article demonstrates a rare anatomical complexity in the mesial root of a mandibular first molar. Four independent root canal orifices were found in this root by clinical detection with the aid of a dental operating microscope. This case shows that additional canals can be located in any root undergoing endodontic treatment and clinicians should always be aware of aberrant internal anatomy.

  19. Laser versus traditional techniques in cerebral and brain stem gliomas

    NASA Astrophysics Data System (ADS)

    Lombard, Gian F.

    1996-01-01

    In medical literature no significant studies have been published on the effectiveness of laser compared with traditional procedures in two series of cerebral gliomas; for this reason we have studied 220 tumors (200 supratentorial -- 20 brain stem gliomas), 110 operated upon with laser, 100 with conventional techniques. Four surgical protocols have been carried out: (1) traditional techniques; (2) carbon dioxide laser free hand; (3) carbon dioxide laser plus microscope; (4) multiple laser sources plus microscope plus neurosector plus CUSA. Two laser sources have been used alone or in combination (carbon dioxide -- Nd:YAG 1.06 or 1.32). Patients have been monitored for Karnofsky scale before and after operation, 12 - 24 and 36 months later; and for survival rate. Tumors were classified by histological examination, dimensions, vascularization, topography (critical or non critical areas). Results for supratentorial gliomas: survival time is the same in both series (laser and traditional). Post- op morbidity is significantly improved in the laser group (high grade sub-group); long term follow-up shows an improvement of quality of life until 36 months in the low grade sub-group.

  20. Identification of a forensic case using microscopy and forensically informative nucleotide sequencing (FINS): a case study of small Indian civet (Viverricula indica).

    PubMed

    Sahajpal, Vivek; Goyal, S P

    2010-06-01

    The exhibits obtained in wildlife offence cases quite often present a challenging situation for the forensic expert. The selection of proper approach for analysis is vital for a successful analysis. A generalised forensic analysis approach should proceed from the use of non-destructive techniques (morphological and microscopic examination) to partially destructive and finally destructive techniques (DNA analysis). The findings of non-destructive techniques may sometime be inconclusive but they definitely help in steering further forensic analysis in a proper direction. We describe a recent case where a very small dried skin piece (<0.05 mg) with just one small trimmed guard hair (0.4 cm) on it was received for species identification. The single guard hair was examined microscopically to get an indication of the type of species. We also describe the extraction procedure with a lower amount of sample, using an automated extraction method (Qiagen Biorobot EZ1) and PCR amplification of three mitochondrial genes (16s rRNA, 12s rRNA and cytochrome b) for species identification. Microscopic examination of the single hair indicated a viverrid species but the initial DNA analysis with 16s rRNA (through NCBI BLAST) showed the highest homology (93%) with a hyaenid species (Hyaena hyaena). However, further DNA analysis based on 12s rRNA and cytochrome b gene proved that the species was indeed a viverrid i.e. Viverricula indica (small Indian civet). The highest homology shown with a Hyaenid species by the 16s rRNA sequence from the case sample was due to lack of a 16s rRNA sequence for Viverricula indica in the NCBI data base. The case highlights the importance of morphological and microscopic examinations in wildlife offence cases. With respect to DNA extraction technology we found that automatic extraction method of Biorobot EZ1 (Qiagen) is quite useful with less amount of sample (much below recommended amount). Copyright 2009 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Onset of industrial pollution recorded in Mumbai mudflat sediments, using integrated magnetic, chemical, 210Pb dating, and microscopic methods.

    PubMed

    Blaha, U; Basavaiah, N; Deenadayalan, K; Borole, D V; Mohite, R D

    2011-01-15

    The onset and rise of urban and industrial pollution in the Mumbai region was reconstructed from an anthropogenically contaminated mudflat sediment profile from the adjacent Thane creek using magnetic parameters, polycyclic aromatic hydrocarbon (PAH) data, metal contents, and the (210)Pb dating technique. The 1.8 m vertical section at Airoli (Navi Mumbai) reveals an increase of magnetic susceptibility (χ) from background values of (20-50) to (75-100) × 10(-8) [m(3) kg(-1)] in the anthropogenically affected zone above ∼93 cm. A sharp rise of χ from (75-100) to (130-215) × 10(-8) [m(3) kg(-1)] subdivides the anthropogenically affected zone at a depth of ∼63 cm. Characterization with rock magnetic parameters (SIRM, Soft IRM, and S-ratio) reveals a significant contribution of ferri(o)magnetic phases in the upper zone. Based on the magnetic classification sampling intervals for cost-intensive PAH and metal analyses were determined. Steadily increasing contents of PAH and metals of anthropogenic origin are observed above the boundary depth at ∼93 cm. A sediment accumulation rate of 1.2 ± 0.3 cm/yr provided by (210)Pb dating dates the ∼63 cm boundary to 1951. Increasing industrial activity, including the establishment of a coal-fired power plant in 1956, and refineries between 1955 and 1960, correlates well with the substantial increase of χ, PAH, and metal contents. Scanning electron microscopy (SEM) investigation on magnetic extracts from the contaminated zone reveals the presence of magnetic spherules derived from industrial high-temperature processes.

  2. Endometrial carcinoma in a single horn of a bicornuate uterus: A case report.

    PubMed

    Gaballa, Khaled; Cicero, Carla; Gallotta, Valerio; Zannoni, Gianfranco; Scambia, Giovanni

    2018-06-01

    We discuss the diagnosis and the management of endometrial carcinoma in a single horn of bicornuate uterus in a 64-year-old woman as a case report. The case underwent laparoscopic radical hysterectomy and bilateral iliac lymphadenectomy. The gross examination of the uterus revealed a bicornuate uterus with a greater horn of 12 × 9 × 8 cm and a smaller horn of 10 × 3 cm. The cavity of the greater horn showed a neoplastic growth of 10 cm with infiltration of about 1,8 cm of the myometrium from whole thickness of 1.9 cm. while the other horn was free of tumor tissue. The microscopic examination of the uterus revealed G2 endometrioid adenocarcinoma of the endometrium of the greater horn with infiltration of more than 50% of the myometrium. In the presence of bicornuate uterus, a bilateral endometrial biopsy should be performed in order to reduce the risk of delayed or missed diagnosis. The management of a case of bicornuate unicollis uterus with endometrial carcinoma in only one horn is the same as patients with endometrial cancer in single uterus and depends mainly on stage and histological grade of the tumor. The possibility of existence of a separate uterine cavity should always be considered when endometrial cancer is clinically suspected but pathology fails to confirm the diagnosis. This points out the importance of a careful physical examination and radiographic evaluation in such cases. Copyright © 2018. Production and hosting by Elsevier B.V.

  3. Track structure model of microscopic energy deposition by protons and heavy ions in segments of neuronal cell dendrites represented by cylinders or spheres

    PubMed Central

    Alp, Murat; Cucinotta, Francis A.

    2017-01-01

    Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (>100 μm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3He and 12C particles at energies corresponding to a distance of 1 cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch. PMID:28554507

  4. Track structure model of microscopic energy deposition by protons and heavy ions in segments of neuronal cell dendrites represented by cylinders or spheres

    NASA Astrophysics Data System (ADS)

    Alp, Murat; Cucinotta, Francis A.

    2017-05-01

    Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (> 100 μm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3He and 12C particles at energies corresponding to a distance of 1 cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch.

  5. Track structure model of microscopic energy deposition by protons and heavy ions in segments of neuronal cell dendrites represented by cylinders or spheres.

    PubMed

    Alp, Murat; Cucinotta, Francis A

    2017-05-01

    Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (> 100µm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3 He and 12 C particles at energies corresponding to a distance of 1cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch. Copyright © 2017. Published by Elsevier Ltd.

  6. Design of a 300-kV gas environmental transmission electron microscope equipped with a cold field emission gun.

    PubMed

    Isakozawa, Shigeto; Nagaoki, Isao; Watabe, Akira; Nagakubo, Yasuhira; Saito, Nobuhiro; Matsumoto, Hiroaki; Zhang, Xiao Feng; Taniguchi, Yoshifumi; Baba, Norio

    2016-08-01

    A new in situ environmental transmission electron microscope (ETEM) was developed based on a 300 kV TEM with a cold field emission gun (CFEG). Particular caution was taken in the ETEM design to assure uncompromised imaging and analytical performance of the TEM. Because of the improved pumping system between the gun and column, the vacuum of CFEG was largely improved and the probe current was sufficiently stabilized to operate without tip flashing for 2-3 h or longer. A high brightness of 2.5 × 10(9) A/cm(2) sr was measured at 300 kV, verifying the high quality of the CFEG electron beam. A specially designed gas injection-heating holder was used in the in situ TEM study at elevated temperatures with or without gas around the TEM specimen. Using this holder in a 10 Pa gas atmosphere and specimen temperatures up to 1000°C, high-resolution ETEM performance and analysis were achieved. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Column densities resulting from shuttle sublimator/evaporator operation. [optical density of nozzle flow containing water vapor

    NASA Technical Reports Server (NTRS)

    Naumann, R. J.

    1973-01-01

    The proposed disposal of H2O from the shuttle fuel cell operation by ejecting it in vapor form through a supersonic nozzle at the rate of 100 lb/day has been investigated from the point of view of the possible interference to astronomical experiments. If the nozzle is located at the tail and directed along the shuttle longitudinal axis, the resulting column density will be less than 10 to th 12th power molecules/sq cm at viewing angles larger than 48 deg above the longitudinal axis. The molecules in the trail will diffuse rapidly. The column density contribution from molecules expelled on the previous orbit is 1.3 x 10 to the 8th power molecules/sq cm. This contribution diminishes by the inverse square root of the number of orbits since the molecules were expelled. The molecular backscatter from atmospheric molecules is also calculated. If the plume is directed into the flight path, the column density along a perpendicular is found to be 1.5 x 10 to the 11th power molecules/sq cm. The return flux is estimated to be of the order of 10 to the 12th power molecules/sq cm/sec at the stagnation point. With reasonable care in design of experiments to protect them from the backscatter flux of water molecules, the expulsion of 100 lb/day does not appear to create an insurmountable difficulty for the shuttle experiments.

  8. The 30-cm ion thruster power processor

    NASA Technical Reports Server (NTRS)

    Herron, B. G.; Hopper, D. J.

    1978-01-01

    A power processor unit for powering and controlling the 30 cm Mercury Electron-Bombardment Ion Thruster was designed, fabricated, and tested. The unit uses a unique and highly efficient transistor bridge inverter power stage in its implementation. The system operated from a 200 to 400 V dc input power bus, provides 12 independently controllable and closely regulated dc power outputs, and has an overall power conditioning capacity of 3.5 kW. Protective circuitry was incorporated as an integral part of the design to assure failure-free operation during transient and steady-state load faults. The implemented unit demonstrated an electrical efficiency between 91.5 and 91.9 at its nominal rated load over the 200 to 400 V dc input bus range.

  9. Palm top plasma focus device as a portable pulsed neutron source.

    PubMed

    Rout, R K; Niranjan, Ram; Mishra, P; Srivastava, R; Rawool, A M; Kaushik, T C; Gupta, Satish C

    2013-06-01

    Development of a palm top plasma focus device generating (5.2 ± 0.8) × 10(4) neutrons∕pulse into 4π steradians with a pulse width of 15 ± 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 μF capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 μF, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of (3)He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

  10. Palm top plasma focus device as a portable pulsed neutron source

    NASA Astrophysics Data System (ADS)

    Rout, R. K.; Niranjan, Ram; Mishra, P.; Srivastava, R.; Rawool, A. M.; Kaushik, T. C.; Gupta, Satish C.

    2013-06-01

    Development of a palm top plasma focus device generating (5.2 ± 0.8) × 104 neutrons/pulse into 4π steradians with a pulse width of 15 ± 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 μF capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 μF, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of 3He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

  11. LPG sensing characteristics of electrospray deposited SnO2 nanoparticles

    NASA Astrophysics Data System (ADS)

    Gürbüz, Mevlüt; Günkaya, Göktuğ; Doğan, Aydın

    2014-11-01

    In this study, SnO2 films were fabricated on conductive substrate such as aluminum and platinum coated alumina using electro-spray deposition (ESD) method for gas sensor applications. Solution flow rate, coating time, substrate-nozzle distance and solid/alcohol ratio were studied to optimize SnO2 film structure. The morphology of the deposited films was characterized by stereo and scanning electron microscopy (SEM). The gas sensing properties of tin oxide films were investigated using liquid petroleum gas (LPG) for various lower explosive limit (LEL). The results obtained from microscopic analyses show that optimum SnO2 films were evaluated at flow rate of 0.05 ml/min, at distance of 6 cm, for 10 min deposition time, for 20 gSnO2/Lethanol ratio and at 7 kV DC electric field. By the results obtained from the gas sensing behavior, the sensitivity of the films was increased with operating temperature. The films showed better sensitivity for 20 LEL LPG concentration at 450 °C operating temperature.

  12. [Cartilage tissue reconstruction by the polymer biomaterials--early macroscopic and histological results].

    PubMed

    Scierski, Wojciech; Polok, Aleksandra; Namysłowski, Grzegorz; Nozyński, Jerzy; Turecka, Lucyna; Urbaniec, Natalia; Pamuła, Elzbieta

    2009-09-01

    The surgical treatment of large cartilage defects in the region of head and neck is often impossible because of the atrophy of surrounding tissues and lack of suitable material for reconstruction. In the surgical treatment many of methods and reconstructive materials have been used. For many years the suitable synthetic material for the cartilage defects reconstruction has been searched for. Was to evaluate two different biomaterials with proper mechanical and biological features for the cartilage replacement. Two type of biomaterials in this study were used: resorbable polymer - poly(L-lactide-co-glycolide) (PLG) acting as a supportive matrix. A thin layer of sodium hyaluronate (Hyal) was also deposited on the surface as well in the pore walls of PLG scaffolds in order to provide biologically active molecules promoting differentiation and regeneration of the tissue. The studies were performed on the 50 animals--rabbits divided into 2 groups. The animals were operated in the general anaesthesia. The incision was done along the edge of the rabbit's auricle. Perichondrium and cartilage of the auricle on the surface 4 x 3 cm were prepared. Subperichondrically 1 x 1 cm fragment of the cartilage was removed by the scissors. This fragment was then replaced by the biomaterials: PLG in first group of 25 rabbits and PLG-Hyal in second group 25 rabbits. The tissues were sutured with polyglycolide Safil 3-0. The animals obtained Enrofloxacin for three days after the operation. Then 1, 4 and 12 weeks after the surgery the animals were painlessly euthanized by an overdose of Morbital. Implants and surrounding tissues were excised and observed macroscopically and using an optical microscope. In all the observation periods we observed proper macroscopic healing process of biomaterials. We didn't stated strong inflammatory process and necrosis around the implanted biomaterials. The histological and macroscopic examinations indicated that both materials developed in this study have properties similar to cartilaginous tissue and seem to be good for her restoration. Although the quickest tissue regeneration was found after implantation of PLG-Hyal.

  13. Nd and Ru co-doped bismuth titanate polycrystalline thin films with improved ferroelectric properties

    NASA Astrophysics Data System (ADS)

    Sahoo, Kishor Kumar; Singh Rajput, Shailendra; Gupta, Rajeev; Roy, Amritendu; Garg, Ashish

    2018-02-01

    We report the ferroelectric properties of pulsed laser deposited thin films of Nd and Ru co-doped bismuth titanate (Bi4-x Nd x Ti3-y Ru y O12). Structural analysis of the as-grown films, using x-ray diffraction, showed a single-phase formation with a polycrystalline structure. In comparison to un-doped and Nd-doped films, ferroelectric measurements on co-doped films demonstrated improved properties with remnant polarization (P r) ~ 12.5 µC cm-2 and an enhanced electrical fatigue life for Bi3.25Nd0.75Ti2.8Ru0.20O12 films. The enhancement in remanent polarization is attributed to microscopic changes, such as local structural distortion and the modification of the dynamical/effective charges on constituent ions due to chemical strain upon simultaneous Bi- (A) and Ti- (B) site doping with Nd and Ru, which has a far stronger effect than only A-site doping with Nd. Piezoresponse force microscopy further confirmed the polar structure and domain switching at nanoscale. The films exhibit small yet finite magnetization at 10 K resulting from strain.

  14. Hydrothermal solid-gas route to TiO2 nanoparticles/nanotube arrays for high-performance supercapacitors

    NASA Astrophysics Data System (ADS)

    Fan, Haowen; Zhang, He; Luo, Xiaolei; Liao, Maoying; Zhu, Xufei; Ma, Jing; Song, Ye

    2017-07-01

    Although TiO2 nanotube arrays (TNTAs) have shown great promise as supercapacitor materials, their specific capacitances are still not comparable with some typical materials. Here, TiO2 nanoparticles (NPs)/TNTAs hybrid structure has been derived from the anodized TNTAs by a facile hydrothermal solid-gas method (HSGM), which can avoid cracking or curling of the TNTAs from Ti substrate. The obtained NPs/TNTAs hybrid structure can exhibit a ∼4.90 times increase in surface area and a ∼5.49 times increase in areal specific capacitance compared to the TNTAs without HSGM treatment. Besides, the argon-atmosphere annealing can offer improved areal capacitance and cycling stability relative to the air-atmosphere annealing. The hydrothermal vapor pressure is a key factor for controlling microscopic morphologies of TNTAs, the morphology transformations of TNTAs during the HSGM treatment can be accelerated under enhanced vapor pressures. The highest areal capacitance of HSGM-treated TNTAs is up to 76.12 mF cm-2 at 0.5 mA cm-2, well above that of any TiO2 materials reported to date.

  15. Primary Ewing sarcoma of vulva, confirmed with molecular cytogenetic analysis: A rare case report with diagnostic and treatment implications.

    PubMed

    Rekhi, Bharat; Chinnaswamy, Girish; Vora, Tushar; Shah, Sneha; Rangarajan, Venkatesh

    2015-01-01

    Primary vulvar Ewing sarcoma (ES)/PNET is an uncommonly documented tumor, especially with molecular results. A 10-year-old girl presented with left vulvar swelling, a year ago. Her abdominopelvic ultrasound revealed a 12 cm × 8 cm sized, mixed echogenic blood-filled lesion in the left vulva; radiologically considered as a hematoma. Vulvectomy revealed a multinodular grey-brown tumor, microscopically comprising malignant round cells. Immunohistochemically, tumor cells diffusely expressed MIC2/CD99 and Fli1 and subsequently displayed EWSR1 rearrangement, confirming diagnosis of ES/PNET. Subsequently, PET-CT scan revealed residual local lesion with lung metastases. The patient was induced on EFT 2001 chemotherapy protocol. Three months after chemotherapy completion, there was no metabolically active disease on PET scan. Four months later, MRI disclosed recurrent primary and metastatic pulmonary lesions. She was planned for scar excision and adjuvant radiotherapy, but unfortunately defaulted further treatment. This forms the eighth case of primary vulvar ES/PNET confirmed with molecular cytogenetic result, underscoring therapeutic value of objective diagnosis in such cases.

  16. Recent conclusions regarding the reconstructive microsurgery of peripheral nerves

    PubMed Central

    Doina, Dumitrescu-Ionescu

    2008-01-01

    The introducing of reconstructive microsurgery has meant not only the addition of microsurgical microscopes and instruments, but a change, a progress towards a new concept, the concept of the microsurgical reconstruction of tissues. The microscope and the instruments themselves are only a means of utilizing this new concept to good effect since the mere use of the microscope and of the instruments according to the old concept of tissue reconstruction cannot be considered to be reconstructive microsurgery. From December 1979 through to December 2005, more than 3.000 patients with peripheral nerve lesions were operated on by the same microsurgeon, the author Doina Ionescu-Dumitrescu. The conclusions are based on the following: • A huge amount of work involved in carrying out microsurgical reconstructions of over 7,500 peripheral nerves in over 3,000 patients, 1,800 of which were nerve transplants for defects of peripheral nerves of the extremities, for posttraumatic brachial plexus paralyses (91), for replantations and/or revascularizations following partial or complete amputations of the extremities (24 out of which 23 successful) or for free transfers of functional composite tissues (53). For a more accurate picture of such an effort one should consider the operation time that these types of reconstruction involve: between 3 and 12 hours for each patient under general anaesthesia and for both the anaesthetist and the microsurgeon. • Experimental microsurgery on rabbit ears • The results of the histopathological examination of 500 postoperative neuromas of peripheral nerves repaired traditionally • The Moberg test • Pre, intra and postoperative monthly observations of the patients until their full recovery according to the criteria set by the International Reconstructive Microsurgery Society (postoperative intervals of 6-12-24 months) • Taking pictures and recording pre, intra and postoperative stages • The patients’ professional, social and familial reintegration • The patients’ state of mind; level of cooperation • Comparing results with those of classic and palliative repairs • Comparing the data resulting from this experience with the information provided by the specialist literature of the world • Completing the internationally defined reconstructive procedures with the personal ones, to produce a new concept The introducing of reconstructive microsurgery has meant not only the addition of microsurgical microscopes and instruments, but a change, a progress towards a new concept, the concept of the microsurgical reconstruction of tissues. The microscope and the instruments themselves are only a means of utilizing this new concept to good effect since the mere use of the microscope and of the instruments according to the old concept of tissue reconstruction cannot be considered to be reconstructive microsurgery. From December 1979 through to December 2005, more than 3.000 patients with peripheral nerve lesions were operated on by the same microsurgeon, the author Doina Ionescu-Dumitrescu. The conclusions are based on the following: • A huge amount of work involved in carrying out microsurgical reconstructions of over 7,500 peripheral nerves in over 3,000 patients, 1,800 of which were nerve transplants for defects of peripheral nerves of the extremities, for posttraumatic brachial plexus paralyses (91), for replantations and/or revascularizations following partial or complete amputations of the extremities (24 out of which 23 successful) or for free transfers of functional composite tissues (53). For a more accurate picture of such an effort one should consider the operation time that these types of reconstruction involve: between 3 and 12 hours for each patient under general anaesthesia and for both the anaesthetist and the microsurgeon. • Experimental microsurgery on rabbit ears • The results of the histopathological examination of 500 postoperative neuromas of peripheral nerves repaired traditionally • The Moberg test • Pre, intra and postoperative monthly observations of the patients until their full recovery according to the criteria set by the International Reconstructive Microsurgery Society (postoperative intervals of 6-12-24 months) • Taking pictures and recording pre, intra and postoperative stages • The patients’ professional, social and familial reintegration • The patients’ state of mind; level of cooperation • Comparing results with those of classic and palliative repairs • Comparing the data resulting from this experience with the information provided by the specialist literature of the world • Completing the internationally defined reconstructive procedures with the personal ones, to produce a new concept PMID:20108464

  17. [Penile augmentation using acellular dermal matrix].

    PubMed

    Zhang, Jin-ming; Cui, Yong-yan; Pan, Shu-juan; Liang, Wei-qiang; Chen, Xiao-xuan

    2004-11-01

    Penile enhancement was performed using acellular dermal matrix. Multiple layers of acellular dermal matrix were placed underneath the penile skin to enlarge its girth. Since March 2002, penile augmentation has been performed on 12 cases using acellular dermal matrix. Postoperatively all the patients had a 1.3-3.1 cm (2.6 cm in average) increase in penile girth in a flaccid state. The penis had normal appearance and feeling without contour deformities. All patients gained sexual ability 3 months after the operation. One had a delayed wound healing due to tight dressing, which was repaired with a scrotal skin flap. Penile enlargement by implantation of multiple layers of acellular dermal matrix was a safe and effective operation. This method can be performed in an outpatient ambulatory setting. The advantages of the acellular dermal matrix over the autogenous dermal fat grafts are elimination of donor site injury and scar and significant shortening of operation time.

  18. High-operating temperature MWIR photon detectors based on type II InAs/GaSb superlattice

    NASA Astrophysics Data System (ADS)

    Razeghi, Manijeh; Nguyen, Binh-Minh; Delaunay, Pierre-Yves; Abdollahi Pour, Siamak; Huang, Edward Kwei-wei; Manukar, Paritosh; Bogdanov, Simeon; Chen, Guanxi

    2010-01-01

    Recent efforts have been paid to elevate the operating temperature of Type II InAs/GaSb superlattice Mid Infrared photon detectors. Optimized growth parameters and interface engineering technique enable high quality material with a quantum efficiency above 50%. Intensive study on device architecture and doping profile has resulted in almost one order of magnitude of improvement to the electrical performance and lifted up the 300K-background BLIP operation temperature to 166K. At 77K, the ~4.2 μm cut-off devices exhibit a differential resistance area product in excess of the measurement system limit (106 Ohm.cm2) and a detectivity of 3x1013cm.Hz1/2/W. High quality focal plane arrays were demonstrated with a noise equivalent temperature of 10mK at 77K. Uncooled camera is capable to capture hot objects such as soldering iron.

  19. Long-duration high-efficiency operation of a continuously pulsed copper laser utilizing copper bromide as a lasant

    NASA Technical Reports Server (NTRS)

    Chen, C. J.; Bhanji, A. M.; Russell, G. R.

    1978-01-01

    A copper laser utilizing copper bromide as a lasant and neon as the buffer gas has been operated at an average laser power of between 16 and 19.5 W for a period of 68 h. Lasing was attained at a pulsing rate of 16.7 kHz in a quartz discharge tube 2.5-cm in diameter with an electrode separation of 200 cm. The laser energy/pulse and peak power/pulse corresponding to an average power of 19.5 W are 1.2 mJ and 30 kW, respectively. The ratio of laser power at 510.6 and 578.2 nm varied from 3.9 to 1.1 corresponding to a total average laser power of 4 and 18 W, respectively. The highest wall plug and capacitor efficiency measured during 68 h of operation were 0.7 and 1.1%, respectively.

  20. Radio astronomy ultra-low-noise amplifier for operation at 91 cm wavelength in high RFI environment

    NASA Astrophysics Data System (ADS)

    Korolev, A. M.; Zakharenko, V. V.; Ulyanov, O. M.

    2016-02-01

    An ultra-low-noise input amplifier intended for a use in a radio telescope operating at 91 cm wavelength is presented. The amplifier noise temperatures are 12.8 ± 1.5 and 10.0 ± 1.5 K at ambient temperatures of 293 and 263 K respectively. The amplifier does not require cryogenic cooling. It can be quickly put in operation thus shortening losses in the telescope observation time. High linearity of the amplifier (output power at 1 dB gain compression P1dB ≥ 22 dBm, output third order intercept point OIP3 ≥ 37 dBm) enables the telescope operation in highly urbanized and industrialized regions. To obtain low noise characteristics along with high linearity, high-electron-mobility field-effect transistors were used in parallel in the circuit developed. The transistors used in the amplifier are cost-effective and commercially available. The circuit solution is recommended for similar devices working in ultra-high frequency band.

  1. Graphene Dendrimer-stabilized silver nanoparticles for detection of methimazole using Surface-enhanced Raman scattering with computational assignment

    NASA Astrophysics Data System (ADS)

    Saleh, Tawfik A.; Al-Shalalfeh, Mutasem M.; Al-Saadi, Abdulaziz A.

    2016-08-01

    Graphene functionalized with polyamidoamine dendrimer, decorated with silver nanoparticles (G-D-Ag), was synthesized and evaluated as a substrate with surface-enhanced Raman scattering (SERS) for methimazole (MTZ) detection. Sodium borohydride was used as a reducing agent to cultivate silver nanoparticles on the dendrimer. The obtained G-D-Ag was characterized by using UV-vis spectroscopy, scanning electron microscope (SEM), high-resolution transmission electron microscope (TEM), Fourier-transformed infrared (FT-IR) and Raman spectroscopy. The SEM image indicated the successful formation of the G-D-Ag. The behavior of MTZ on the G-D-Ag as a reliable and robust substrate was investigated by SERS, which indicated mostly a chemical interaction between G-D-Ag and MTZ. The bands of the MTZ normal spectra at 1538, 1463, 1342, 1278, 1156, 1092, 1016, 600, 525 and 410 cm-1 were enhanced due to the SERS effect. Correlations between the logarithmical scale of MTZ concentrations and SERS signal intensities were established, and a low detection limit of 1.43 × 10-12 M was successfully obtained. The density functional theory (DFT) approach was utilized to provide reliable assignment of the key Raman bands.

  2. Cell migration under ultrasound irradiations in micrometer scale

    NASA Astrophysics Data System (ADS)

    Murakami, Shinya; Otsuka, Yo; Oshima, Yusuke; Hikita, Atsuhiko; Mitsui, Toshiyuki

    2013-03-01

    Cell movements, migration play an important role in many physiological processes including cell proliferation and differentiation. C2C12, a line of mouse myoblasts is known to differentiate into osteoblast under appropriate conditions. Therefore, C2C12 cells can be chosen for the differentiation studies. However, the movement of the C2C12's has not been fully investigated although the movements may provide a better understanding of the healing processes of bone repair, regeneration and differentiation. In addition, low intensity ultrasound has been thought and used to promote bone fracture healing although the microscopic mechanism of this healing is not well understood. As a first step, we have investigated single cell migration of C2C12 under optical microscopy with and without ultrasound irradiations. The ultrasound is irradiated from an apex of a sharp needle. The frequency is 1.5 MHz and the power intensity is near 24 mW/cm2. These values were similar to the ultrasound treatment values. In this conference, we will show the influence of the ultrasound irradiation on the cell movement by plotting the mean squared displacement and the velocity autocorrelation function as a function of time.

  3. [Effect of hydrostatic pressure on intracellular free calcium concentration and transient receptor potential vanilloid expression in human bladder smooth muscle cells].

    PubMed

    Han, Zhenwei; Wang, Kunjie; Chen, Lin; Wei, Tangqiang; Luo, Deyi; Li, Shengfu

    2012-04-01

    To explore the effect of hydrostatic pressure on intracellular free calcium concentration ([Ca2+]i) and the gene expression of transient receptor potential vanilloid (TRPV) in cultured human bladder smooth muscle cells (hb-SMCs), and to preliminarily probe into the possible molecular mechanism of hb-SMCs proliferation stimulated by hydrostatic pressure. The passage 6-7 hb-SMCs were loaded with Ca2+ indicator Fluo-3/AM. When the hb-SMCs were under 0 cm H2O (1cm H2O = 0.098 kPa) (group A) or 200 cm H2O hydrostatic pressure for 30 minutes (group B) and then removing the 200 cm H2O hydrostatic pressure (group C), the [Ca2+]i was measured respectively by inverted laser scanning confocal microscope. When the hb-SMCs were given the 200 cm H2O hydrostatic pressure for 0 hour, 2 hours, 6 hours, 12 hours, and 24 hours, the mRNA expressions of TRPV1, TRPV2, and TRPV4 were detected by RT-PCR technique. The [Ca2+]i of group A, group B, and group C were (100.808 +/- 1.724), (122.008 +/- 1.575), and (99.918 +/- 0.887) U, respectively; group B was significantly higher than groups A and C (P < 0.001). The [Ca2+]i of group C decreased to the base line level of group A after removing the pressure (t = 0.919, P = 0.394). The TRPV1, TRPV2, and TRPV4 genes expressed in hb-SMCs under 200 cm H2O hydrostatic pressure at 0 hour, 2 hours, 6 hours, 12 hours, and 24 hours, but the expressions had no obvious changes with time. There was no significant difference in the expressions of TRPV1, TRPV2, and TRPV4 among 3 groups (P > 0.05). The [Ca2+]i of hb-SMCs increases significantly under high hydrostatic pressure. As possible genes in stretch-activated cation channel, the TRPV1, TRPV2, and TRPV4 express in hb-SMCs under 200 cm H2O hydrostatic pressure. It is possible that the mechanical pressure regulates the [Ca2+]i of hb-SMCs by opening the stretch-activated cation channel rather than up-regulating its expression.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Q. G.; Chen, N.; Zhang, M.

    Five IDs will be built for the Shanghai Synchrotron Radiation Facility (SSRF). Two identical mini-gap undulators with the period length 25mm and the minimum gap 6mm will use the in-vacuum technology and can operate in tapered mode. Two wigglers with the period lengths 7.9cm and 14cm and the same minimum gap 14mm will produce the peak fields of 1.2T and 1.94T. A variable polarization undulator of the APPLE-II type with 4.2m long and the period length 10cm can provide linearly, circularly and elliptically polarized radiation in a wide spectral range. This paper describes the magnet designs and the mechanical structuremore » designs of these IDs.« less

  5. Assessment of the performance characteristics of a prototype 12-element capacitive contact flexible microstrip applicator (CFMA-12) for superficial hyperthermia.

    PubMed

    Lee, W M; Gelvich, E A; van der Baan, P; Mazokhin, V N; van Rhoon, G C

    2004-09-01

    The electrical performance of the CFMA-12 operating at 433 MHz is assessed under laboratory conditions using a RF network analyser. From measurements of the scattering parameters of the CFMA-12 on both a multi-layered muscle- and fat/muscle-equivalent phantom, the optimal water bolus thickness, at which the transfer of the energy to the phantom configuration is maximal, is determined to be approximately 1 cm. The SAR distribution of the CFMA-12 in a multi-layered muscle-equivalent phantom is characterized using Schottky diode sheets and a TVS-600 IR camera. From the SAR measurements using the Schottky diode sheets it is shown that the contribution of the E(x) component to the SAR (SAR(x)) is maximal 7% of the contribution of the E(y)component to the SAR (SAR(y)) at different layers in both phantom configurations. The complete SAR distribution (SAR(tot)) at different depths is measured using the power pulse technique. From these measurements, it can be seen that SAR(y)at a depth of 0 cm in the muscle-equivalent phantom represents up to 80% of SAR(tot). At 1 and 2 cm depth, SAR(y) is up to 95% of SAR(tot). Therefore, in homogeneous muscle-equivalent phantoms, E(y) is the largest E-field component and measurement of SAR(y) distribution is sufficient to characterize SAR-steering performance of the CFMA-12. SAR steering measurements at 1 cm depth in the muscle-equivalent phantom show that the SAR maximum varies by 40% (1 SD) around the average value of 38.8 W kg(-1) (range 10-65 W kg(-1)) between single antenna elements. The effective fieldsize (E(50)) varies by 14% (1 SD) around the average value of 19.1 cm(2).

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patel, Piyush, E-mail: piyush-patel130@yahoo.com; Vyas, S. M., E-mail: s-m-vyas-gu@hotmail.com; Patel, Vimal

    The III-VI compound semiconductors is important for the fabrication of ionizing radiation detectors, solid-state electrodes, and photosensitive heterostructures, solar cell and ionic batteries. In this paper, In{sub 2}Se{sub 2.7} Sb{sub 0.3} single crystals were grown by the Bridgman method with temperature gradient of 60 °C/cm and the growth velocity 0.5cm/hr. The as-grown crystals were examined under the optical microscope for surface study, a various growth features observed on top free surface of the single crystal which is predominant of layers growth mechanism. The lattice parameters of as-grown crystal was determined by the XRD analysis. A Vickers’ projection microscope were usedmore » for the study of microhardness on the as-cleaved, cold-worked and annealed samples of the crystals, the results were discussed, and reported in detail.« less

  7. A case report of coup de sabre patient with hair transplantation.

    PubMed

    Dai, Yeqin; Xu, Ai-E; He, Junhua

    2017-09-01

    Treatment of coup de sabre must remain conservative until the disease is no longer in an active state. When activity has ceased, some operative intervention is safe and effective for the correction of deformity. While hair transplantation showed high survival rates for the correction of cicatricial alopecia, it has rarely reported to be performed for the correction of coup de sabre. To assess the therapeutic possibility of hair transplantation for the correction of coup de sabre. Follicular units consisting of two to three hairs from the patient's occipital scalp were transplanted and followed-up for 12 months. After 12 months of follow-up, treatment outcomes showed an 86.7% survival rate and 12-16 cm (mean 14 cm) length of the transplanted hairs. When coup de sabre is no longer in an active state, hair transplantation is a useful method for cosmetic improvement of the alopecia.

  8. Histogenesis and disappearance of the teeth of the Mekong giant catfish, Pangasianodon gigas (Teleostei).

    PubMed

    Kakizawa, Yoshiko; Meenakarn, Wanpen

    2003-12-01

    Juveniles of the Mekong giant catfish, Pangasianodon gigas (Teleostei), have 3 sorts of tooth-upper and lower jaw teeth, palatal teeth, and pharyngeal teeth--but adults are toothless. To investigate the histogenesis and disappearance of the teeth, we made serial sections of the mouth and teeth of juvenile fish at 10 developmental stages (from ca. 8.5 to ca. 30 cm in total length) and examined them under scanning electron microscope and light microscope. Observations of teeth and surrounding tissues in the serial sections revealed the process of tooth resorption by active odontoclast-like cells. Numbers of jaw and palatal teeth decreased with age. When the fish reached ca. 14 cm in total length, the numbers of functional upper jaw teeth and successional tooth germs decreased rapidly, and the developmental rate of successional tooth germs slowed. When the fish reached ca. 24 cm, no teeth existed in the upper jaw. It is clear that tooth disappearance results from the shedding of functional teeth and the lack of replacement tooth germs.

  9. Spine surgeon's kinematics during discectomy, part II: operating table height and visualization methods, including microscope.

    PubMed

    Park, Jeong Yoon; Kim, Kyung Hyun; Kuh, Sung Uk; Chin, Dong Kyu; Kim, Keun Su; Cho, Yong Eun

    2014-05-01

    Surgeon spine angle during surgery was studied ergonomically and the kinematics of the surgeon's spine was related with musculoskeletal fatigue and pain. Spine angles varied depending on operation table height and visualization method, and in a previous paper we showed that the use of a loupe and a table height at the midpoint between the umbilicus and the sternum are optimal for reducing musculoskeletal loading. However, no studies have previously included a microscope as a possible visualization method. The objective of this study is to assess differences in surgeon spine angles depending on operating table height and visualization method, including microscope. We enrolled 18 experienced spine surgeons for this study, who each performed a discectomy using a spine surgery simulator. Three different methods were used to visualize the surgical field (naked eye, loupe, microscope) and three different operating table heights (anterior superior iliac spine, umbilicus, the midpoint between the umbilicus and the sternum) were studied. Whole spine angles were compared for three different views during the discectomy simulation: midline, ipsilateral, and contralateral. A 16-camera optoelectronic motion analysis system was used, and 16 markers were placed from the head to the pelvis. Lumbar lordosis, thoracic kyphosis, cervical lordosis, and occipital angle were compared between the different operating table heights and visualization methods as well as a natural standing position. Whole spine angles differed significantly depending on visualization method. All parameters were closer to natural standing values when discectomy was performed with a microscope, and there were no differences between the naked eye and the loupe. Whole spine angles were also found to differ from the natural standing position depending on operating table height, and became closer to natural standing position values as the operating table height increased, independent of the visualization method. When using a microscope, lumbar lordosis, thoracic kyphosis, and cervical lordosis showed no differences according to table heights above the umbilicus. This study suggests that the use of a microscope and a table height above the umbilicus are optimal for reducing surgeon musculoskeletal fatigue.

  10. Final Technical Report: Affordable, High-Performance, Intermediate Temperature Solid Oxide Fuel Cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blackburn, Bryan M.; Bishop, Sean; Gore, Colin

    In this project, we improved the power output and voltage efficiency of our intermediate temperature solid oxide fuel cells (IT-SOFCs) with a focus on ~600 °C operation. At these temperatures and with the increased power density (i.e., fewer cells for same power output), the stack cost should be greatly reduced while extending durability. Most SOFC stacks operate at temperatures greater than 800 °C. This can greatly increase the cost of the system (stacks and BOP) as well as maintenance costs since the most common degradation mechanisms are thermally driven. Our approach uses no platinum group metal (PGM) materials and themore » lower operating temperature allows use of simple stainless steel interconnects and commercial off-the-shelf gaskets in the stack. Furthermore, for combined heating and power (CHP) applications the stack exhaust still provides “high quality” waste heat that can be recovered and used in a chiller or boiler. The anticipated performance, durability, and resulting cost improvements (< $700/kWe) will also move us closer to reaching the full potential of this technology for distributed generation (DG) and residential/commercial CHP. This includes eventual extension to cleaner, more efficient portable generators, auxiliary power units (APUs), and range extenders for transportation. The research added to the understanding of the area investigated by exploring various methods for increasing power density (Watts/square centimeter of active area in each cell) and increasing cell efficiency (increasing the open circuit voltage, or cell voltage with zero external electrical current). The results from this work demonstrated an optimized cell that had greater than 1 W/cm2 at 600 °C and greater than 1.6 W/cm2 at 650 °C. This was demonstrated in large format sizes using both 5 cm by 5 cm and 10 cm by 10 cm cells. Furthermore, this work demonstrated that high stability (no degradation over > 500 hours) can be achieved together with high performance in large format cells as large as 10 cm by 10 cm when operated at ~600 °C. The project culminated in the demonstration of a 12-cell stack using the porous anode-based SOFC technology.« less

  11. 4D microscope-integrated OCT improves accuracy of ophthalmic surgical maneuvers

    NASA Astrophysics Data System (ADS)

    Carrasco-Zevallos, Oscar; Keller, Brenton; Viehland, Christian; Shen, Liangbo; Todorich, Bozho; Shieh, Christine; Kuo, Anthony; Toth, Cynthia; Izatt, Joseph A.

    2016-03-01

    Ophthalmic surgeons manipulate micron-scale tissues using stereopsis through an operating microscope and instrument shadowing for depth perception. While ophthalmic microsurgery has benefitted from rapid advances in instrumentation and techniques, the basic principles of the stereo operating microscope have not changed since the 1930's. Optical Coherence Tomography (OCT) has revolutionized ophthalmic imaging and is now the gold standard for preoperative and postoperative evaluation of most retinal and many corneal procedures. We and others have developed initial microscope-integrated OCT (MIOCT) systems for concurrent OCT and operating microscope imaging, but these are limited to 2D real-time imaging and require offline post-processing for 3D rendering and visualization. Our previously presented 4D MIOCT system can record and display the 3D surgical field stereoscopically through the microscope oculars using a dual-channel heads-up display (HUD) at up to 10 micron-scale volumes per second. In this work, we show that 4D MIOCT guidance improves the accuracy of depth-based microsurgical maneuvers (with statistical significance) in mock surgery trials in a wet lab environment. Additionally, 4D MIOCT was successfully performed in 38/45 (84%) posterior and 14/14 (100%) anterior eye human surgeries, and revealed previously unrecognized lesions that were invisible through the operating microscope. These lesions, such as residual and potentially damaging retinal deformation during pathologic membrane peeling, were visualized in real-time by the surgeon. Our integrated system provides an enhanced 4D surgical visualization platform that can improve current ophthalmic surgical practice and may help develop and refine future microsurgical techniques.

  12. Morphological and structural effects on tungsten targets produced by fusion plasma pulses from a table top plasma focus

    NASA Astrophysics Data System (ADS)

    Inestrosa-Izurieta, M. J.; Ramos-Moore, E.; Soto, L.

    2015-09-01

    A table top plasma focus device operating at hundreds of joules was used to simulate an equivalent damage factor than the obtained on the divertor in tokamak experiments. Using the ejected plasma produced after the pinch disruptions, the effects on tungsten targets from 50 cumulative plasma shocks with power fluxes per shot between 2.6 and 9200 kW cm-2 and with a duration time in the order of tens of nanoseconds (damage factor in the order of 100-103 (W cm-2)s1/2) were studied. Morphological analysis shows an increasing appearance of cracked surfaces with holes, fissures and defects, suggesting a potential progression of stress effects and a fast heat load that melts the surface, ending in thermal contractions that recrystallize the surface of the target. A structural analysis demonstrates a compressive stress development and suggests that part of the energy is released in the melting of the surface in case of a plasma shock with a power flux of 9.2 MW cm-2, 75 ns duration pulse, 2.5   ×   103 (W cm-2)s1/2 damage factor. How to increase the damage factor by one order of magnitude up to the expected value from type I ELMs on the ITER divertor, i.e. 104 (W cm-2)s1/2 is discussed.

  13. Air-Operated Sump Pump

    NASA Technical Reports Server (NTRS)

    Nolt, Gary D.

    1988-01-01

    Pump removes liquid seepage from small, restricted area and against large pressure head. Developed for moving small amounts of water and oil from sump pit 85 ft (25.91 m) deep. Fits in space only 6 1/2 in. (16.5 cm) in diameter and 18 in. (45.7 cm) long. In discharge part of pumping cycle, air forces liquid out of pump chamber through pipe. During filling part of pumping cycle, water enters pump chamber from sump pit. Float in chamber next to pump chamber controls pressurization through timer and solenoid valve.

  14. Elastic scattering and breakup reactions of the exotic nucleus 8B on nuclear targets

    NASA Astrophysics Data System (ADS)

    Lukyanov, V. K.; Kadrev, D. N.; Antonov, A. N.; Zemlyanaya, E. V.; Lukyanov, K. V.; Gaidarov, M. K.; Spasova, K.

    2018-05-01

    Microscopic calculations of the optical potentials (OPs) and elastic scattering cross sections of the proton-rich nucleus 8B on 12C, 58Ni and 208Pb targets are presented. The density distributions of 8B obtained within the variational Monte Carlo (VMC) model and the three-cluster model (3CM) are used to construct the optical potentials (OP). The real part of the hybrid OP (ReOP) is calculated using the folding model with the direct and exchange terms included, while the imaginary part (ImOP) is obtained on the base of the high energy approximation (HEA). In addition, the cluster model, in which 8B consists of a proton halo and a 7Be core is applied to calculate the breakup cross sections of 8B on 9Be, 12C and 197Au targets, as well as the momentum distributions of 7Be fragments. A comparison with the available experimental data is made and a good agreement is obtained.

  15. Surface Characterization of Carbon Fiber Polymer Composites and Aluminum Alloys After Laser Interference Structuring

    NASA Astrophysics Data System (ADS)

    Sabau, Adrian S.; Greer, Clayton M.; Chen, Jian; Warren, Charles D.; Daniel, Claus

    2016-07-01

    The increasing use of carbon fiber-reinforced polymer matrix composites (CFPC) and aluminum alloys as lightweight materials in the automotive and aerospace industries demands enhanced surface preparation and control of surface morphology prior to joining. In this study, surfaces of both composite and aluminum were prepared for joining using an Nd:YAG laser in a two-beam interference setup, enabling the (1) structuring of the AL 5182 surface, (2) removal of the resin layer on top of carbon fibers, and (3) structuring of the carbon fibers. CFPC specimens of T700S carbon fiber, Prepreg—T83 epoxy, 5 ply thick, 0°/90° plaques were used. The effects of laser fluence, scanning speed, and number of shots-per-spot were investigated on the removal rate of the resin without an excessive damage of the fibers. Optical micrographs, 3D imaging, and scanning electron microscope imaging were used to study the effect of the laser processing on the surface morphology. It was found that an effective resin ablation and a low density of broken fibers for CFPC specimens was attained using laser fluences of 1-2 J/cm2 and number of 2-4 pulses per spot. A relatively large area of periodic line structures due to energy interference were formed on the aluminum surface at laser fluences of 12 J/cm2 and number of 4-6 pulses per spot.

  16. CT differentiation of 1-2-cm gallbladder polyps: benign vs malignant.

    PubMed

    Song, E Rang; Chung, Woo-Suk; Jang, Hye Young; Yoon, Minjae; Cha, Eun Jung

    2014-04-01

    To evaluate MDCT findings of 1-2-cm sized gallbladder (GB) polyps for differentiation between benign and malignant polyps. Institutional review board approval was obtained, and informed consent was waived. Portal venous phase CT scans of 1-2-cm sized GB polyps caused by various pathologic conditions were retrospectively reviewed by two blinded observers. Among the 36 patients identified, 21 had benign polyps with the remaining 15 having malignant polyps. Size, margin, and shape of GB polyps were evaluated. Attenuation values of the polyps, including mean attenuation, maximum attenuation, and standard deviation, were recorded. As determined by visual inspection, the degree of polyp enhancement was evaluated. Using these CT findings, each of the two radiologists assessed and recorded individual diagnostic confidence for differentiating benign versus malignant polyps on a 5-point scale. The diagnostic performance of CT was evaluated using a receiver operating characteristic curve analysis. There was no significant difference in size between benign and malignant GB polyps. Ill-defined margin and sessile morphology were significantly associated with malignant polyp. There was a significant difference in mean and maximum attenuation values between benign and malignant GB polyps. Mean standard deviation value of malignant polyps was significantly higher than that of benign polyps. All malignant polyps showed either hyperenhancement or marked hyperenhancement. A z value for the diagnosis of malignant GB polyps was 0.905. Margin, shape, and enhancement degree are helpful in differentiating between benign and malignant polyps of 1-2-cm sizes.

  17. MgB2 Thin-Film Bolometer for Applications in Far-Infrared Instruments on Future Planetary Missions

    NASA Technical Reports Server (NTRS)

    Lakew, B.; Aslam, S.; Brasunas, J.; Cao, N.; Costen, N.; La, A.; Stevenson, T.; Waczynski, A.

    2012-01-01

    A SiN membrane based MgB2 thin-film bolometer, with a non-optimized absorber, has been fabricated that shows an electrical noise equivalent power of 256 fW/square root Hz operating at 30 Hz in the 8.5 - 12.35 micron spectral bandpass. This value corresponds to an electrical specific detectivity of 7.6 x 10(exp 10) cm square root Hz/W. The bolometer shows a measured blackbody (optical) specific detectivity of 8.8 x 10(exp 9) cm square root Hz/W, with a responsivity of 701.5 kV/W and a first-order time constant of 5.2 ms. It is predicted that with the inclusion of a gold black absorber that a blackbody specific detectivity of 6.4 x 10(exp 10) cm/square root Hz/W at an operational frequency of 10 Hz, can be realized for integration into future planetary exploration instrumentation where high sensitivity is required in the 17 - 250 micron spectral wavelength range.

  18. Colour stereociné photography with twin cameras through the operation microscope.

    PubMed

    Phillips, C I; McDonald, A J

    1975-01-01

    Two Beaulieu R16 cinecameras attached toa Zeiss operation microscope, OP Mi2, one for each side, produced colour cine films. When these were projected through polarizing filters on to a silver screen, the audience (wearing appropriately oriented polarizing spectacles) achieved a stereoscopic view.

  19. Microscopic derivation of particle-based coarse-grained dynamics: Exact expression for memory function

    NASA Astrophysics Data System (ADS)

    Izvekov, Sergei

    2017-03-01

    We consider the generalized Langevin equations of motion describing exactly the particle-based coarse-grained dynamics in the classical microscopic ensemble that were derived recently within the Mori-Zwanzig formalism based on new projection operators [S. Izvekov, J. Chem. Phys. 138(13), 134106 (2013)]. The fundamental difference between the new family of projection operators and the standard Zwanzig projection operator used in the past to derive the coarse-grained equations of motion is that the new operators average out the explicit irrelevant trajectories leading to the possibility of solving the projected dynamics exactly. We clarify the definition of the projection operators and revisit the formalism to compute the projected dynamics exactly for the microscopic system in equilibrium. The resulting expression for the projected force is in the form of a "generalized additive fluctuating force" describing the departure of the generalized microscopic force associated with the coarse-grained coordinate from its projection. Starting with this key expression, we formulate a new exact formula for the memory function in terms of microscopic and coarse-grained conservative forces. We conclude by studying two independent limiting cases of practical importance: the Markov limit (vanishing correlations of projected force) and the limit of weak dependence of the memory function on the particle momenta. We present computationally affordable expressions which can be efficiently evaluated from standard molecular dynamics simulations.

  20. [Antegrade extended peroneal artery perforator flap for knee reconstruction].

    PubMed

    Ruan, Hongjiang; Cai, Peihua; Fan, Cunyi; Chai, Yimin; Liu, Shenghe

    2009-03-01

    To investigate the operative technique and clinical results of repairing the soft tissue defects of knee with antegrade extended peroneal artery perforator flap. From October 2007 to January 2008, 3 patients (2 men and 1 woman) with the soft tissue defects of knee were treated, with the ages of 18, 31 and 42 years, respectively. The first case sustained femur and pelvis fractures and soft tissue defect over his right popliteal fossa, which were treated with open reduction and internal fixation (ORIF) and debridement of knee joint 2 weeks ago. The second case was necrosis of skin 3 weeks after ORIF for fracture of tibial plateau. The third case suffered from open fracture of tibial plateau and soft tissue defect, which were treated with external fixation and debridement 3 weeks ago. The defect sizes were 16 cm x 9 cm, 11 cm x 6 cm and 14 cm x 7 cm. The flap was raised by dividing the peroneal artery and veins distally and elevating them proximally, which covered for the defects of knee. The flaps were designed with the size of 18 cm x 10 cm, 12 cm 7 cm and 15 cm x 8 cm. The pure vascular pedicle of the flap was 10 cm to 17 cm in length, including the peroneal vessels and one or two perforator branches. The donor site is covered by a split thickness skin graft. All flaps survived after surgery. The donor sites healed by first intention and the skin grafts survived. After following up for 6, 8 and 11 months, the appearance and function of the flaps were all satisfactory. Based on the modified HSS knee performance system, post-operative knee functional outcomes of three patients were excellent. The antegrade extended peroneal artery perforator flap supplied by a pure vascular pedicle can be a good alternative for reconstruction of knee. The flap, with a long and thin pure vascular pedicle, could provide good texture and contour matching the recipient area.

  1. Anatomy and histology of the frontalis muscle.

    PubMed

    Costin, Bryan R; Plesec, Thomas P; Sakolsatayadorn, Natta; Rubinstein, Tal J; McBride, Jennifer M; Perry, Julian D

    2015-01-01

    To determine the gross and histologic configurations of the medial and lateral frontalis muscle. After making a midcoronal incision and bluntly dissecting to the orbital rim, the frontalis muscle was marked and measured. A protractor was used to measure the frontalis-orbicularis angle (FOA) and, when present, the angle of central bifurcation (AOB). Three strips of full-thickness forehead soft tissue measuring 0.5 cm × 8 cm were excised 3, 4.5, and 6 cm above the supraorbital notch and analyzed histologically for the presence of skeletal muscle fibers. Data were analyzed using 2-sample t tests, paired t tests, Pearson correlations, and mixed effect models. A p value of ≤ 0.05 was considered statistically significant. Sixty-four hemifaces of 32 cadavers (16 males) were dissected. All specimens were Caucasian. The average age was 78.2 years (range, 56-102 years). The average FOA was 88.7° (13.0°), and the average AOB was 90.0° (26.4°). A visible midline bifurcation occurred in 28 of 32 subjects (88%) at an average height of 4.7 cm (range, 2.4-7.2 cm) superior to the supraorbital notch. Continuous skeletal muscle fibers were present within the midline bifurcation histologically in 89%, 75%, and 11% of specimens 3.5, 5.0, and 6.5 cm above the supraorbital notch, respectively. In 46% of individuals, skeletal muscle fibers were continuously present microscopically within the gross bifurcation. While a medial frontalis muscle bifurcation occurs grossly in most senescent Caucasians, muscle fibers exist microscopically within this zone in nearly half of individuals.

  2. Design, Fabrication, and Characterization of Hematite (α-Fe2O3) Nanostructures

    NASA Astrophysics Data System (ADS)

    Jansi Rani, B.; Mageswari, R.; Ravi, G.; Ganesh, V.; Yuvakkumar, R.

    2017-12-01

    The influence of processing parameters on the physicochemical properties of hematite α-Fe2O3 nanostructures was investigated. X-ray diffraction results revealed the hematite phase rhombohedral structure. Scanning electron microscope results explored nanospheres, nanohexagonal platelets, nanoellipsoids, distorted nanocubes, and interconnected platelets nanostructures. Rhombohedral single-phase hematite was confirmed through five Raman active modes. 2 P 3/2 (1) → 2 P 1/2 transition in photoluminescence spectra and Fourier-transform infrared spectroscopy band observed at 555 cm-1 revealed the hematite formation. The highest specific capacitance value of 151.09 F/g for scan rate of 10 mV/s was obtained for the hydrothermal-assisted product using an Fe(NO3)2·9H2O precursor in KOH electrolyte solutions.

  3. Change of magnetic properties of nanocrystalline alloys under influence of external factors

    NASA Astrophysics Data System (ADS)

    Sitek, Jozef; Holková, Dominika; Dekan, Julius; Novák, Patrik

    2016-10-01

    Nanocrystalline (Fe3Ni1)81Nb7B12 alloys were irradiated using different types of radiation and subsequently studied by Mössbauer spectroscopy. External magnetic field of 0.5 T, electron-beam irradiation up to 4 MGy, neutron irradiation up to 1017 neutrons/cm2 and irradiation with Cu ions were applied on the samples. All types of external factors had an influence on the magnetic microstructure manifested as a change in the direction of the net magnetic moment, intensity of the internal magnetic field and volumetric fraction of the constituent phases. The direction of the net magnetic moment was the most sensitive parameter. Changes of the microscopic magnetic parameters were compared after different external influence and results of nanocrystalline samples were compared with their amorphous precursors.

  4. Track reconstruction in the emulsion-lead target of the OPERA experiment using the ESS microscope

    NASA Astrophysics Data System (ADS)

    Arrabito, L.; Bozza, C.; Buontempo, S.; Consiglio, L.; Cozzi, M.; D'Ambrosio, N.; DeLellis, G.; DeSerio, M.; Di Capua, F.; Di Ferdinando, D.; Di Marco, N.; Ereditato, A.; Esposito, L. S.; Fini, R. A.; Giacomelli, G.; Giorgini, M.; Grella, G.; Ieva, M.; Janicsko Csathy, J.; Juget, F.; Kreslo, I.; Laktineh, I.; Manai, K.; Mandrioli, G.; Marotta, A.; Migliozzi, P.; Monacelli, P.; Moser, U.; Muciaccia, M. T.; Pastore, A.; Patrizii, L.; Petukhov, Y.; Pistillo, C.; Pozzato, M.; Romano, G.; Rosa, G.; Russo, A.; Savvinov, N.; Schembri, A.; Scotto Lavina, L.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Strolin, P.; Tioukov, V.; Waelchli, T.

    2007-05-01

    The OPERA experiment, designed to conclusively prove the existence of νμ→ντ oscillations in the atmospheric sector, makes use of a massive lead-nuclear emulsion target to observe the appearance of ντ's in the CNGS νμ beam. The location and analysis of the neutrino interactions in quasi real-time required the development of fast computer-controlled microscopes able to reconstruct particle tracks with sub-micron precision and high efficiency at a speed of ~20 cm2/h. This paper describes the performance in particle track reconstruction of the European Scanning System, a novel automatic microscope for the measurement of emulsion films developed for OPERA.

  5. Fourier transform emission spectroscopy of the F4Δ- X4Φ system of TiF

    NASA Astrophysics Data System (ADS)

    Ram, R. S.; Bernath, P. F.

    2005-06-01

    The emission spectra of TiF have been reinvestigated in the 4200-15 000 cm -1 region using the Fourier transform spectrometer associated with the National Solar Observatory at Kitt Peak. TiF was formed in a microwave discharge lamp operated with 2.5 Torr of He and a trace of TiF 4 vapor, and the spectra were recorded at a resolution of 0.02 cm -1. The TiF bands observed in the 12 000-14 000 cm -1 region have been assigned to a new transition, F4Δ- X4Φ. Each band consists of four sub-bands assigned as, 4Δ 1/2- 4Φ 3/2, 4Δ 3/2- 4Φ 5/2, 4Δ 5/2- 4Φ 7/2, and 4Δ 7/2- 4Φ 9/2. A rotational analysis of the 0-1, 0-0, and 1-0 bands has been obtained and spectroscopic constants have been extracted.

  6. New minimally access hydrocelectomy.

    PubMed

    Saber, Aly

    2011-02-01

    To ascertain the acceptability of minimally access hydrocelectomy through a 2-cm incision and the outcome in terms of morbidity reduction and recurrence rate. Although controversy exists regarding the treatment of hydrocele, hydrocelectomy remains the treatment of choice for hydroceles. However, the standard surgical procedures for hydrocele can cause postoperative discomfort and complications. A total of 42 adult patients, aged 18-56 years, underwent hydrocelectomy as an outpatient procedure using a 2-cm scrotal skin incision and excision of only a small disk of the parietal tunica vaginalis. The operative time was 12-18 minutes (mean 15). The outcome measures included patient satisfaction and postoperative complications. This procedure requires minor dissection and minimal manipulation during treatment. It also resulted in no recurrence and minimal complications and required a short operative time. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Very low cost real time histogram-based contrast enhancer utilizing fixed-point DSP processing

    NASA Astrophysics Data System (ADS)

    McCaffrey, Nathaniel J.; Pantuso, Francis P.

    1998-03-01

    A real time contrast enhancement system utilizing histogram- based algorithms has been developed to operate on standard composite video signals. This low-cost DSP based system is designed with fixed-point algorithms and an off-chip look up table (LUT) to reduce the cost considerably over other contemporary approaches. This paper describes several real- time contrast enhancing systems advanced at the Sarnoff Corporation for high-speed visible and infrared cameras. The fixed-point enhancer was derived from these high performance cameras. The enhancer digitizes analog video and spatially subsamples the stream to qualify the scene's luminance. Simultaneously, the video is streamed through a LUT that has been programmed with the previous calculation. Reducing division operations by subsampling reduces calculation- cycles and also allows the processor to be used with cameras of nominal resolutions. All values are written to the LUT during blanking so no frames are lost. The enhancer measures 13 cm X 6.4 cm X 3.2 cm, operates off 9 VAC and consumes 12 W. This processor is small and inexpensive enough to be mounted with field deployed security cameras and can be used for surveillance, video forensics and real- time medical imaging.

  8. Helium ion microscopy of graphene: beam damage, image quality and edge contrast

    NASA Astrophysics Data System (ADS)

    Fox, D.; Zhou, Y. B.; O'Neill, A.; Kumar, S.; Wang, J. J.; Coleman, J. N.; Duesberg, G. S.; Donegan, J. F.; Zhang, H. Z.

    2013-08-01

    A study to analyse beam damage, image quality and edge contrast in the helium ion microscope (HIM) has been undertaken. The sample investigated was graphene. Raman spectroscopy was used to quantify the disorder that can be introduced into the graphene as a function of helium ion dose. The effects of the dose on both freestanding and supported graphene were compared. These doses were then correlated directly to image quality by imaging graphene flakes at high magnification. It was found that a high magnification image with a good signal to noise ratio will introduce very significant sample damage. A safe imaging dose of the order of 1013 He+ cm-2 was established, with both graphene samples becoming highly defective at doses over 5 × 1014 He+ cm-2. The edge contrast of a freestanding graphene flake imaged in the HIM was then compared with the contrast of the same flake observed in a scanning electron microscope and a transmission electron microscope. Very strong edge sensitivity was observed in the HIM. This enhanced edge sensitivity over the other techniques investigated makes the HIM a powerful nanoscale dimensional metrology tool, with the capability of both fabricating and imaging features with sub-nanometre resolution.

  9. Enhancement of fusion at near-barrier energies for neutron-rich light nuclei: 19O +12 C

    NASA Astrophysics Data System (ADS)

    Singh, Varinderjit; Vadas, J.; Steinbach, T. K.; Wiggins, B. B.; Hudan, S.; Desouza, R. T.; Baby, L. T.; Kuvin, S. A.; Tripathi, Vandana; Wiedenhover, I.; Umar, A. S.

    2017-01-01

    Measuring the fusion excitation function for an isotopic chain of projectile nuclei provides a sensitive test of a microscopic description of fusion. To investigate the theoretically predicted fusion enhancement for neutron-rich light nuclei, an experiment was performed to measure the fusion excitation functions for 19 O +12 C and 18 O +12 C . Using the 18O(d,p) reaction and the RESOLUT mass spectrometer at Florida State University, a beam of 19O was produced with an intensity of 2-4 x 103 p/s. This beam bombarded a 100 μg/cm2 carbon target. Using an approach optimized for the measurement of fusion with a low-intensity beam, evaporation residues (ERs) resulting from the de-excitation of the fusion product were measured. The ERs were identified by measuring their energy and time-of-flight. At near-barrier energies, an enhancement of fusion by a factor of three has been observed for 19 O +12 C in comparison to 18 O +12 C . Comparison of the experimental results with the predictions of a density constrained time-dependent Hartree-Fock (DC-TDHF) model provide evidence for the importance of pairing in the fusion process. Supported by the US DOE under Grant No. DEFG02-88ER-40404.

  10. Palm top plasma focus device as a portable pulsed neutron source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rout, R. K.; Niranjan, Ram; Srivastava, R.

    2013-06-15

    Development of a palm top plasma focus device generating (5.2 {+-} 0.8) Multiplication-Sign 10{sup 4} neutrons/pulse into 4{pi} steradians with a pulse width of 15 {+-} 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is ofmore » 2 {mu}F capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 {mu}F, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of {sup 3}He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.« less

  11. Use of computed tomography to assess volume change after endoscopic orbital decompression for Graves' ophthalmopathy.

    PubMed

    Schiff, Bradley A; McMullen, Caitlin P; Farinhas, Joaquim; Jackman, Alexis H; Hagiwara, Mari; McKellop, Jason; Lui, Yvonne W

    2015-01-01

    Orbital decompression is frequently performed in the management of patients with sight-threatening and disfiguring Graves' ophthalmopathy. The quantitative measurements of the change in orbital volume after orbital decompression procedures are not definitively known. Furthermore, the quantitative effect of septal deviation on volume change has not been previously analyzed. To provide quantitative measurement of orbital volume change after medial and inferior endoscopic decompression and describe a straightforward method of measuring this change using open-source technologies. A secondary objective was to assess the effect of septal deviation on orbital volume change. A retrospective review was performed on all patients undergoing medial and inferior endoscopic orbital decompression for Graves' ophthalmopathy at a tertiary care academic medical center. Pre-operative and post-operative orbital volumes were calculated from computed tomography (CT) data using a semi-automated segmenting technique and Osirix™, an open-source DICOM reader. Data were collected for pre-operative and post-operative orbital volumes, degree of septal deviation, time to follow-up scan, and individual patient Hertel scores. Nine patients (12 orbits) were imaged before and after decompression. Mean pre-operative orbital volume was 26.99 cm(3) (SD=2.86 cm(3)). Mean post-operative volume was 33.07 cm(3) (SD=3.96 cm(3)). The mean change in volume was 6.08 cm(3) (SD=2.31 cm(3)). The mean change in Hertel score was 4.83 (SD=0.75). Regression analysis of change in volume versus follow-up time to imaging indicates that follow-up time to imaging has little effect on change in volume (R=-0.2), and overall mean maximal septal deviation toward the operative side was -0.5mm. Negative values were attributed to deviation away form the operative site. A significant correlation was demonstrated between change in orbital volume and septal deviation distance site (R=0.66), as well as between change in orbital volume and septal deviation angle (R=0.67). Greater volume changes were associated with greater degree of septal deviation away from the surgical site, whereas smaller volume changes were associated with greater degree of septal deviation toward the surgical site. A straightforward, semi-automated segmenting technique for measuring change in volume following endoscopic orbital decompression is described. This method proved useful in determining that a mean increase of approximately 6 cm in volume was achieved in this group of patients undergoing medial and inferior orbital decompression. Septal deviation appears to have an effect on the surgical outcome and should be considered during operative planning. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. A dark-field microscope for background-free detection of resonance fluorescence from single semiconductor quantum dots operating in a set-and-forget mode

    NASA Astrophysics Data System (ADS)

    Kuhlmann, Andreas V.; Houel, Julien; Brunner, Daniel; Ludwig, Arne; Reuter, Dirk; Wieck, Andreas D.; Warburton, Richard J.

    2013-07-01

    Optically active quantum dots, for instance self-assembled InGaAs quantum dots, are potentially excellent single photon sources. The fidelity of the single photons is much improved using resonant rather than non-resonant excitation. With resonant excitation, the challenge is to distinguish between resonance fluorescence and scattered laser light. We have met this challenge by creating a polarization-based dark-field microscope to measure the resonance fluorescence from a single quantum dot at low temperature. We achieve a suppression of the scattered laser exceeding a factor of 107 and background-free detection of resonance fluorescence. The same optical setup operates over the entire quantum dot emission range (920-980 nm) and also in high magnetic fields. The major development is the outstanding long-term stability: once the dark-field point has been established, the microscope operates for days without alignment. The mechanical and optical designs of the microscope are presented, as well as exemplary resonance fluorescence spectroscopy results on individual quantum dots to underline the microscope's excellent performance.

  13. Non-transectional open gastric bypass as the definitive bariatric procedure for 61 patients with BMI of 70 and higher.

    PubMed

    Slotman, Gus J

    2010-01-01

    Technical difficulties in laparoscopic gastric bypass for severely obese patients have led to sleeve gastrectomy first and then laparoscopic gastric bypass as a second stage after significant weight loss. Rather than commit these fragile patients to two operations, we have done open gastric bypass as a definitive surgical treatment for extreme obesity. Office records of 61 patients with body mass index (BMI) of 70 and higher were reviewed. All underwent non-transectional open gastric bypass with a 150 cm Roux limb. Data included age, sex, weight, BMI, co-morbidities, operative information, length of stay (LOS), surgical morbidity, and percent excess weight loss (%XSWL). Data are in median (range). There were 21 (34%) men and 40 (66%) women: age, 37 years (19-53); pre-operative weight, 468 lb (300-650); and pre-operative BMI, 77 (70-95). Co-morbidities were diabetes mellitus, 26 (46%); hypertension, 26 (43%); sleep apnea, 61 (100%); gastroesophageal reflux disease, 20 (33%); and hypothyroid nine (15%). Incision length was 15 cm (12-20), abdominal wall fat thickness was 8 cm (5-13), operative time was 150 min (100-210), and estimated blood loss was 100 ml (25-750); post-op intensive care unit: yes 16 (26%) and no 44 (74%). LOS was 3 days for 44 patients (74%), 4 days for 11 (18%), 5 days for five (8%), and 7 days for one (1.6%). Post-operative morbidity was as follows: zero mortality, splenectomy, stoma leak, deep venous thrombosis, pulmonary embolus, GI bleeding, stomal ulcer, intestinal obstruction, fascial dehiscence, or 30-day readmission; wound infections in one (1.6%); skin wound separation in six (10%); pneumonia in one (1.6%); anemia in nine (14.8%); vitamin B(12) deficiency in six (10%); incisional hernia in 17 (28%); and gastric staple line disruption in two (3.3%). %XSWL were 51% in 1 year (28-84) and 60% in 2 years (27-97). Non-transectional open gastric bypass for patients with BMI of 70 and higher is safe and effective as a one-stage operation for severe obesity.

  14. Cavity ring-down spectroscopy using an EC-QCL operating at 7.5 µm for direct monitoring of methane isotopes in air

    NASA Astrophysics Data System (ADS)

    Maity, Abhijit; Pal, Mithun; Dutta Banik, Gourab; Maithani, Sanchi; Pradhan, Manik

    2017-11-01

    A number of atmospheric pollutants and greenhouse gases have strong fundamental vibrational transitions within the spectral range of 7.5-8 µm, which marks the region as particularly important for trace gas sensing. Here, we report the development of a mid-infrared continuous-wave (cw) cavity ring-down spectroscopy (CRDS) technique coupled with an external-cavity (EC) mode-hop-free quantum cascade laser (QCL) operating at 7.5 µm. We validated the EC-QCL based high-resolution cw-CRDS system by measuring 12CH4 and 13CH4 isotopes of methane (CH4) which served as a benchmark molecule. The direct, quantitative and selective measurements of 12C and 13C isotopes of CH4 in ambient air as well as in human breath samples in the levels of parts per billion by volume were made by probing one of the strongest fundamental vibrational transitions of CH4 arising from the asymmetric bending (ν 4 band) vibrations of the bonds centred at ~1327.244 cm-1 and ~1332.946 cm-1, respectively. We achieved a noise-equivalent absorption coefficient of 1.86  ×  10-9 cm-1 Hz-1/2 with 100 Hz data acquisition rate for the current cw-CRDS spectrometer. The current high-resolution cw-CRDS system could be further exploited to harness the full advantage of the spectral region covering 7.5-8 µm to monitor several other trace molecular species along with their isotopic compositions.

  15. Prospective multicenter registration study of colorectal cancer: significant variations in radicality and oncosurgical quality-Swiss Group for Clinical Cancer Research Protocol SAKK 40/00.

    PubMed

    Maurer, Christoph A; Dietrich, Daniel; Schilling, Martin K; Metzger, Urs; Laffer, Urban; Buchmann, Peter; Lerf, Bruno; Villiger, Peter; Melcher, Gian; Klaiber, Christian; Bilat, Christian; Brauchli, Peter; Terracciano, Luigi; Kessler, Katharina

    2017-01-01

    This study aimed to investigate in a multicenter cohort study the radicality of colorectal cancer resections, to assess the oncosurgical quality of colorectal specimens, and to compare the performance between centers. One German and nine Swiss hospitals agreed to prospectively register all patients with primary colorectal cancer resected between September 2001 and June 2005. The median number of eligible patients with one primary tumor included per center was 95 (range 12-204). The following variations of median values or percentages between centers were found: length of bowel specimen 20-39 cm (25.8 cm), maximum height of mesocolon 6.5-12.5 cm (9.0 cm), number of examined lymph nodes 9-24 (16), distance to nearer bowel resection margin in colon cancer 4.8-12 cm (7 cm), and in rectal cancer 2-3 cm (2.5 cm), central ligation of major artery 40-97 % (71 %), blood loss 200-500 ml (300 ml), need for perioperative blood transfusion 5-40 % (19 %), tumor opened during mobilization 0-11 % (5 %), T4-tumors not en-bloc resected 0-33 % (4 %), inadvertent perforation of mesocolon/mesorectum 0-8 % (4 %), no-touch isolation technique 36-86 % (67 %), abdominoperineal resection for rectal cancer 0-30 % (17 %), rectal cancer specimen with circumferential margin ≤1 mm 0-19 % (10 %), in-hospital mortality 0-6 % (2 %), anastomotic leak or intra-abdominal abscess 0-17 % (7 %), re-operation 0-17 % (8 %). In colorectal cancer, surgery considerable variations between different centers were found with regard to radicality and oncosurgical quality, suggesting a potential for targeted improvement of surgical technique.

  16. Low-velocity collision behaviour of clusters composed of sub-millimetre sized dust aggregates

    NASA Astrophysics Data System (ADS)

    Brisset, J.; Heißelmann, D.; Kothe, S.; Weidling, R.; Blum, J.

    2017-07-01

    Context. The experiment results presented apply to the very first stages of planet formation, when small dust aggregates collide in the protoplanetary disc and grow into bigger clusters. In 2011, before flying on the REXUS 12 suborbital rocket in 2012, the Suborbital Particle and Aggregation Experiment (SPACE) performed drop tower flights. We present the results of this first microgravity campaign. Aims: The experiments presented aim to measure the outcome of collisions between sub-mm sized protoplanetary dust aggregate analogues. We also observed the clusters formed from these aggregates and their collision behaviour. Methods: The experiments were performed at the drop tower in Bremen. The protoplanetary dust analogue materials were micrometre-sized monodisperse and polydisperse SiO2 particles prepared into aggregates with sizes between 120 μm and 250 μm. One of the dust samples contained aggregates that were previously compacted through repeated bouncing. During three flights of 9 s of microgravity each, individual collisions between aggregates and the formation of clusters of up to a few millimetres in size were observed. In addition, the collisions of clusters with the experiment cell walls leading to compaction or fragmentation were recorded. Results: We observed collisions amongst dust aggregates and collisions between dust clusters and the cell aluminium walls at speeds ranging from about 0.1 cm s-1 to 20 cm s-1. The velocities at which sticking occurred ranged from 0.18 to 5.0 cm s-1 for aggregates composed of monodisperse dust, with an average value of 2.1 ± 0.9 cm s-1 for reduced masses ranging from 1.2 × 10-6 to 1.8 × 10-3 g with an average value of 2.2+16-2.1 × 10-4 g. The velocities at which bouncing occurred ranged from 1.9 to 11.9 cm s-1 for the same aggregates with an average of 5.9 ± 3.2 cm s-1 for reduced masses ranging from 2.1 × 10-6 to 2.4 × 10-4 with an average of 7.8 ± 2.4 × 10-5 g. The velocities at which fragmentation occurred ranged from 4.9 to 23.8 cm s-1 for the same aggregates with an average of 10.1 ± 3.2 cm s-1 for reduced masses ranging from 1.2 × 10-5 to 1.2 × 10-3 with an average value of 4.2 ± 2.4 × 10-4 g. From the restructuring and fragmentation of clusters composed of dust aggregates colliding with the aluminium cell walls, we derived a collision recipe for dust aggregates ( 100 μm) following the model of Dominik & Tielens (1997, ApJ, 480, 647) developed for microscopic particles. We measured a critical rolling energy of 1.8 ± 0.9 × 10-13 J and a critical breaking energy of 3.5 ± 1.5 × 10-13 J for 100 μm-sized non-compacted aggregates. A movie associated to Fig. 3 is available at http://www.aanda.org

  17. Design, Fabrication and Testing of Multilayer Coated X-Ray Optics for the Water Window Imaging X-Ray Microscope

    NASA Technical Reports Server (NTRS)

    Spencer, Dwight C.

    1996-01-01

    Hoover et. al. built and tested two imaging Schwarzschild multilayer microscopes. These instruments were constructed as prototypes for the "Water Window Imaging X-Ray Microscope," which is a doubly reflecting, multilayer x-ray microscope configured to operate within the "water window." The "water window" is the narrow region of the x-ray spectrum between the K absorption edges of oxygen (lamda = 23.3 Angstroms) and of carbon (lamda = 43.62 Angstroms), where water is relatively highly transmissive and carbon is highly absorptive. This property of these materials, thus permits the use of high resolution multilayer x-ray microscopes for producing high contrast images of carbon-based structures within the aqueous physiological environments of living cells. We report the design, fabrication and testing of multilayer optics that operate in this regime.

  18. [Injuries after lobectomy: a prospective randomized comparison of video-assisted thoracoscopic surgery and mini-thoracotomy].

    PubMed

    Long, Hao; Lin, Zhi-chao; Situ, Dong-rong

    2008-03-15

    To compare the differences of injuries and recovery between video-assisted thoracoscopic surgery (VATS) and mini-thoracotomy (MT) in patients with clinical early stage non-small cell lung cancer (NSCLC) after lobectomy. From March 2004 to December 2006, 47 consecutive patients with early stage NSCLC with a diameter of tumor less than 6 cm were recruited and randomized to VATS group and MT group. Incision length, duration of operation and intraoperative blood loss were recorded. Postoperative pain was assessed using a visual analogue scale before operation and daily for the first 7 days after operation. The serum levels of interleukin-6 (IL-6) and interleukin-10 (IL-10) were measured by cytometric bead array before operation and at 4, 24, and 48 h after operation. Karnofsky performance status (KPS) was assessed before operation and daily for the first 7 days after operation. Incision length was (6.0 +/- 0. 9) cm in the VATS group and (12.5 +/- 1.5) cm in the MT group. There was no significant difference in duration of operation and intraoperative blood loss between the VATS group and the MT group. Postoperative pain was significantly less in the VATS group in the 5th to 7th day postoperatively (P < 0.05). There was no significant difference of serum concentrations of IL-6 and IL-10 between the VATS group and the MT group at 4, 24, and 48 h after operation. KPS score was significantly higher in the VATS group on 2nd to 7th day postoperatively (P < 0.05). Compared with MT, VATS for lobectomy has less postoperative pain, faster recovery, but can't reduce postoperative release of cytokines.

  19. Optimal debulking targets in women with advanced stage ovarian cancer: a retrospective study of immediate versus interval debulking surgery.

    PubMed

    Altman, Alon D; Nelson, Gregg; Chu, Pamela; Nation, Jill; Ghatage, Prafull

    2012-06-01

    The objective of this study was to examine both overall and disease-free survival of patients with advanced stage ovarian cancer after immediate or interval debulking surgery based on residual disease. We performed a retrospective chart review at the Tom Baker Cancer Centre in Calgary, Alberta of patients with pathologically confirmed stage III or IV ovarian cancer, fallopian tube cancer, or primary peritoneal cancer between 2003 and 2007. We collected data on the dates of diagnosis, recurrence, and death; cancer stage and grade, patients' age, surgery performed, and residual disease. One hundred ninety-two patients were included in the final analysis. The optimal debulking rate with immediate surgery was 64.8%, and with interval surgery it was 85.9%. There were improved overall and disease-free survival rates for optimally debulked disease (< 1 cm) with both immediate and interval surgery (P < 0.001) compared to suboptimally debulked disease. Overall survival rates for optimally debulked disease were not significantly different in patients having immediate and interval surgery (P = 0.25). In the immediate surgery group, patients with microscopic residual disease had better disease-free survival (P = 0.015) and overall survival (P = 0.005) than patients with < 1 cm residual disease. In patients who had interval surgery, those who had microscopic residual disease had more improved disease-free survival than those with < 1 cm disease (P = 0.05), but they did not have more improved overall survival (P = 0.42). Patients with microscopic residual disease who had immediate surgery had a significantly better overall survival rate than those who had interval surgery (P = 0.034). In women with advanced stage ovarian cancer, the goal of surgery should be resection of disease to microscopic residual at the initial procedure. This results in improved overall survival than lesser degrees of resection. Further studies are required to determine optimal surgical management.

  20. Localization and Quantification of Trace-gas Fugitive Emissions Using a Portable Optical Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Eric; Teng, Chu; van Kessel, Theodore

    We present a portable optical spectrometer for fugitive emissions monitoring of methane (CH4). The sensor operation is based on tunable diode laser absorption spectroscopy (TDLAS), using a 5 cm open path design, and targets the 2ν3 R(4) CH4 transition at 6057.1 cm-1 (1651 nm) to avoid cross-talk with common interfering atmospheric constituents. Sensitivity analysis indicates a normalized precision of 2.0 ppmv∙Hz-1/2, corresponding to a noise-equivalent absorption (NEA) of 4.4×10-6 Hz-1/2 and minimum detectible absorption (MDA) coefficient of αmin = 8.8×10-7 cm-1∙Hz-1/2. Our TDLAS sensor is deployed at the Methane Emissions Technology Evaluation Center (METEC) at Colorado State University (CSU) formore » initial demonstration of single-sensor based source localization and quantification of CH4 fugitive emissions. The TDLAS sensor is concurrently deployed with a customized chemi-resistive metal-oxide (MOX) sensor for accuracy benchmarking, demonstrating good visual correlation of the concentration time-series. Initial angle-of-arrival (AOA) results will be shown, and development towards source magnitude estimation will be described.« less

  1. Safety of Microsurgery Under Loupes Versus Microscope: A Head-to-Head Comparison of 2 Surgeons With Similar Experiences.

    PubMed

    Ehanire, Tosan; Singhal, Dhruv; Mast, Bruce; Leyngold, Mark

    2018-01-24

    Microsurgery is performed using either the operating microscope or loupe magnification. Use of the operating microscope is considered the "criterion standard"; however, loupes are emerging as a safe and reliable technique to perform microsurgery. The purpose of this study was to analyze the safety of microsurgery under loupe magnification compared with the microscope. Previous studies discussing the safety of loupe magnification during microsurgery have been published; however, this is the first study to compare free flap outcomes from 2 surgeons at the same institution, each using their respective technique. The outcomes were compared by retrospective chart review of 116 patients, and 148 microvascular free tissue transfers were performed between January 1, 2013, and July 15, 2016, by 2 surgeons (D.S.) and (M.L.). Patients' demographics, free flap failure rate, and other surgical complications were analyzed. Statistical significance was determined by unpaired t test, and χ analysis was used to determine statistical significance in proportions between groups. Thirty-eight percent of flaps were performed under ×3.5 loupe magnification and 62% under the operating microscope. Most free flaps used were deep inferior epigastric perforator or muscle sparing transverse rectus abdominis flaps (52%) for breast reconstruction, remainder of free flaps included ALT, radial forearm, and latissimus dorsi for a variety of reconstructive applications. There was no significant difference between the loupes and microscope groups in intraoperative anastomotic revision rate (27% vs 17%), postoperative arterial or venous thrombosis (4.4% vs 2.6%, 5.4% vs 2.2%), flap loss (3.6% vs 2.2%), or median length of stay (6 days vs 6.5 days). The loupe magnification group had statistically significant shorter setup time (20 minutes, P < 0.01). Consistent with previously reported studies, we found no statistical difference in free flap outcomes and safety under loupe magnification compared with the operating microscope. This is the first study to demonstrate these findings with 2 microsurgeons both in their first 3 years in practice, with similar training and experience, operating at the same institution and given the same resources, each using either microscopes or loupes for microsurgery.

  2. [EFFECTIVENESS OF PREPERITONEAL HERNIORRHAPHY WITH Ultrapro Plug MESH FOR UMBILICAL HERNIA REPAIR IN ADULTS].

    PubMed

    Xie, Yanyan; Ma, Dongyang; Song, Yinghan; Lu, Anqing; Wang, Menghong; Lei, Wenzhang

    2016-06-08

    To explore the effectiveness of preperitoneal herniorrhaphy with Ultrapro Plug (UPP) mesh for umbilical hernia repair in adults. Between September 2011 and June 2015, 71 patients with umbilical hernia underwent preperitoneal herniorrhaphy with UPP mesh. There were 26 males and 45 females, aged 19-92 years (mean, 54.3 years). The disease duration was 45 days to 30 years (median, 18 months). Umbilical hernia was diagnosed through physical examination, ultrasound, and other relevant auxiliary examination. According to American Society of Anesthesiologists (ASA) classification, 12 cases were rated as grade Ⅰ, 34 cases as grade Ⅱ, 21 cases as grade Ⅲ, and 4?cases as grade Ⅳ. The operation time, postoperative hospitalization time, complication, and recurrence were recorded. The diameter of hernia ring ranged 0.5-3.0 cm (mean, 1.8 cm). There was no vessel or intestine injury. The operation time was 12-35 minutes (mean, 22.4 minutes); postoperative hospitalization time was 12-48 hours (mean, 16.3 hours). Fat liquefaction of incision occurred in 2 cases, and primary healing of incision was obtained in the other cases. Sixty-nine patients were followed up 8-51 months (median, 28 months). Hernia recurrence and patch infection occurred in 1 case respectively during follow-up. No postoperative foreign body sensation and chronic pain occurred. Repairing umbilical hernia in adults with UPP mesh should be safe and reliable, because it has the advantages of short operation time, short hospital stay, less complication, and lower incidence of recurrence.

  3. Microdose fluorescence imaging of ABY-029 on an operating microscope adapted by custom illumination and imaging modules.

    PubMed

    Elliott, Jonathan T; Dsouza, Alisha V; Marra, Kayla; Pogue, Brian W; Roberts, David W; Paulsen, Keith D

    2016-09-01

    Fluorescence guided surgery has the potential to positively impact surgical oncology; current operating microscopes and stand-alone imaging systems are too insensitive or too cumbersome to maximally take advantage of new tumor-specific agents developed through the microdose pathway. To this end, a custom-built illumination and imaging module enabling picomolar-sensitive near-infrared fluorescence imaging on a commercial operating microscope is described. The limits of detection and system specifications are characterized, and in vivo efficacy of the system in detecting ABY-029 is evaluated in a rat orthotopic glioma model following microdose injections, showing the suitability of the device for microdose phase 0 clinical trials.

  4. Microdose fluorescence imaging of ABY-029 on an operating microscope adapted by custom illumination and imaging modules

    PubMed Central

    Dsouza, Alisha V.; Marra, Kayla; Pogue, Brian W.; Roberts, David W.; Paulsen, Keith D.

    2016-01-01

    Fluorescence guided surgery has the potential to positively impact surgical oncology; current operating microscopes and stand-alone imaging systems are too insensitive or too cumbersome to maximally take advantage of new tumor-specific agents developed through the microdose pathway. To this end, a custom-built illumination and imaging module enabling picomolar-sensitive near-infrared fluorescence imaging on a commercial operating microscope is described. The limits of detection and system specifications are characterized, and in vivo efficacy of the system in detecting ABY-029 is evaluated in a rat orthotopic glioma model following microdose injections, showing the suitability of the device for microdose phase 0 clinical trials. PMID:27699098

  5. The endocrine polypeptide cells of the human stomach, duodenum, and jejunum

    PubMed Central

    Pearse, A. G. E.; Coulling, I.; Weavers, B.; Friesen, S.

    1970-01-01

    Thirty specimens of stomach, duodenum, and jejunum, removed at operation, were examined by optical microscopical, cytochemical, and electron microscopical techniques. The overall distribution of four types of endocrine polypeptide cell in the stomach, and three in the intestine, was determined. The seven cell types are described by names and letters belonging to a scheme for nomenclature agreed upon at the 1969 Wiesbaden conference on gastrointestinal hormones. The gastrin-secreting G cell was the only cell for which firm identification with a known hormone was possible. Although there was wide variation in the distribution of the various cells, from one case to another, striking differences were nevertheless observable, with respect to the G cell, between antra from carcinoma and from ulcer cases. ImagesFig. 2Fig. 3Fig. 4Fig. 5Fig. 6Fig. 7Fig. 8Fig. 9Fig. 10Fig. 11Fig. 12Fig. 13Fig. 14Fig. 15Fig. 16Fig. 17 PMID:4919258

  6. Giant midline abdominal incisional herniae repair through combined retro-rectus mesh placement and components separation: experience from a single centre.

    PubMed

    Kumar, R; Shrestha, A K; Basu, S

    2014-10-01

    Giant midline abdominal wall incisional herniae require repair/reconstruction to restore the structural and functional continuity of the anterior abdominal wall. We describe here our approach to these demanding cases through a combined retro-rectus mesh placement and components separation and their overall functional outcome. A retrospective analysis of a prospectively collected data was carried out and 28 patients who underwent giant (≥15 cm) midline incisional hernia reconstruction were identified in a large district general hospital between 2007 and 2013 with a median follow-up of 34 (6-76) months. Demographic data of our series include age of 60 (median) (30-87) years with a M:F ratio of 12:16, length of symptomatic hernia 18 (median) (12-36) months, more than two previous laparotomies (15), bowel obstructive symptoms (7) and recurrent herniation (7). BMI recorded was 32 (median) (24-46) and ASA of II (median) (I-III). Co-morbidities included cardiac disease (6), diabetes (6), respiratory disease (4) and systemic immunocompromise (2). Operative and technical details showed operative duration to be 180 (median) min, cranio-caudal rectus sheath defect 21 (median) cm, transverse rectus sheath defect 15 (median) cm, cross-sectional area of fascial defect 300 (median) cm(2) and size of mesh 690 (median) cm(2). Seven (25 %) developed short-term post operative complications: grade I seromata all resolving spontaneously (5); grade II superficial wound infections (2). Twenty-five (89 %) were completely asymptomatic at 34 (median) months' follow-up; 2 (7 %) reported mild pain, but not limiting any activity; 1 (4 %) described pain occasionally limiting activity. There was no clinical recurrence with one patient developing global bulging. Our series is comparable to the literature in patient cohort demographics, co-morbidity and risk factor profile; however, we demonstrate an excellent intermediate term outcome with no clinical recurrence and an improvement in quality of life, through their ability to perform normal day to day activities.

  7. Successful resection of metachronous para-aortic, Virchow lymph node and liver metastatic recurrence of rectal cancer.

    PubMed

    Takeshita, Nobuyoshi; Fukunaga, Toru; Kimura, Masayuki; Sugamoto, Yuji; Tasaki, Kentaro; Hoshino, Isamu; Ota, Takumi; Maruyama, Tetsuro; Tamachi, Tomohide; Hosokawa, Takashi; Asai, Yo; Matsubara, Hisahiro

    2015-11-28

    A 66-year-old female presented with the main complaint of defecation trouble and abdominal distention. With diagnosis of rectal cancer, cSS, cN0, cH0, cP0, cM0 cStage II, Hartmann's operation with D3 lymph node dissection was performed and a para-aortic lymph node and a disseminated node near the primary tumor were resected. Histological examination showed moderately differentiated adenocarcinoma, pSS, pN3, pH0, pP1, pM1 (para-aortic lymph node, dissemination) fStage IV. After the operation, the patient received chemotherapy with FOLFIRI regimen. After 12 cycles of FOLFIRI regimen, computed tomography (CT) detected an 11 mm of liver metastasis in the postero-inferior segment of right hepatic lobe. With diagnosis of liver metastatic recurrence, we performed partial hepatectomy. Histological examination revealed moderately differentiated adenocarcinoma as a metastatic rectal cancer with cut end microscopically positive. After the second operation, the patient received chemotherapy with TS1 alone for 2 years. Ten months after the break, CT detected a 20 mm of para-aortic lymph node metastasis and a 10 mm of lymph node metastasis at the hepato-duodenal ligament. With diagnosis of lymph node metastatic recurrences, we performed lymph node dissection. Histological examination revealed moderately differentiated adenocarcinoma as metastatic rectal cancer in para-aortic and hepato-duodenal ligament areas. After the third operation, we started chemotherapy with modified FOLFOX6 regimen. After 2 cycles of modified FOLFOX6 regimen, due to the onset of neutropenia and liver dysfunction, we switched to capecitabine alone and continued it for 6 mo and then stopped. Eleven months after the break, CT detected two swelling 12 mm of lymph nodes at the left supraclavicular region. With diagnosis of Virchow lymph node metastatic recurrence, we started chemotherapy with capecitabine plus bevacizumab regimen. Due to the onset of neutropenia and hand foot syndrome (Grade 3), we managed to continue capecitabine administration with extension of interval period and dose reduction. After 2 years and 2 mo from starting capecitabine plus bevacizumab regimen, Virchow lymph nodes had slowly grown up to 17 mm. Because no recurrence had been detected besides Virchow lymph nodes for this follow up period, considering the side effects and quality of life, surgical resection was selected. We performed left supraclavicular lymph node dissection. Histological examination revealed moderately differentiated adenocarcinoma as a metastatic rectal cancer. After the fourth operation, the patient selected follow up without chemotherapy. Now we follow up her without recurrence and keep her quality of life high.

  8. Nanoimaging using soft X-ray and EUV laser-plasma sources

    NASA Astrophysics Data System (ADS)

    Wachulak, Przemyslaw; Torrisi, Alfio; Ayele, Mesfin; Bartnik, Andrzej; Czwartos, Joanna; Węgrzyński, Łukasz; Fok, Tomasz; Fiedorowicz, Henryk

    2018-01-01

    In this work we present three experimental, compact desk-top imaging systems: SXR and EUV full field microscopes and the SXR contact microscope. The systems are based on laser-plasma EUV and SXR sources based on a double stream gas puff target. The EUV and SXR full field microscopes, operating at 13.8 nm and 2.88 nm wavelengths are capable of imaging nanostructures with a sub-50 nm spatial resolution and short (seconds) exposure times. The SXR contact microscope operates in the "water-window" spectral range and produces an imprint of the internal structure of the imaged sample in a thin layer of SXR sensitive photoresist. Applications of such desk-top EUV and SXR microscopes, mostly for biological samples (CT26 fibroblast cells and Keratinocytes) are also presented. Details about the sources, the microscopes as well as the imaging results for various objects will be presented and discussed. The development of such compact imaging systems may be important to the new research related to biological, material science and nanotechnology applications.

  9. Measurements and modeling of long-path 12CH4 spectra in the 4800-5300 cm-1 region

    NASA Astrophysics Data System (ADS)

    Nikitin, A. V.; Thomas, X.; Régalia, L.; Daumont, L.; Rey, M.; Tashkun, S. A.; Tyuterev, Vl. G.; Brown, L. R.

    2014-05-01

    A new study of 12CH4 line positions and intensities was performed for the lower portion of the Tetradecad region between 4800 and 5300 cm-1 using long path (1603 m) spectra of normal sample CH4 at three pressures recorded with the Fourier transform spectrometer in Reims, France. Line positions and intensities were retrieved by least square curve-fitting procedures and analyzed using the effective Hamiltonian and the effective Dipole moment expressed in terms of irreducible tensor operators adapted to spherical top molecules. An existing spectrum of enriched 13CH4 was used to discern the isotopic lines. A new measured linelist produced positions and intensities for 5851 features (a factor of two more than prior work). Assignments were made for 46% of these; 2725 experimental line positions and 1764 selected line intensities were fitted with RMS standard deviations of 0.004 cm-1 and 7.3%, respectively. The RMS of prior intensity fits of the lower Tetradecad was previously a factor of two worse. The sum of observed intensities between 4800 and 5300 cm-1 fell within 5% of the predicted value from variational calculations.

  10. Online SEOP polarization of Large Area Neutron Spin Filters

    NASA Astrophysics Data System (ADS)

    Babcock, Earl; Salhi, Zahir; Ioffe, Alexander

    2015-04-01

    The Juelich Center for neutron Science has a program to use SEOP polarized 3He Neutron Spin Filters (3He NSF) on many neutron scattering instruments. The main applications are for polarization analysis of the scattered beam. As such, the devices must operate in close proximity to the neutron sample and sample environment which can include complicated cryostats, humidity and pressure cells, and high field magnets. Thus we have developed novel magnetic cavities to house the 3He NSF cells which allow for simultaneous optical pumping on the instruments. Further we continually develop and redevelop the laser sources which must be relatively narrow band and have long term (i.e. months) stability and robust operation. The first fully operational polarizer has been used continuously for over 2, 60-day reactor cycles at the FRM2. This device uses a 12.5 cm I.D. 3He cell, and has a 3He storage lifetime, including the cells lifetime, in excess of 200 hours with the cell about 60 cm from the sample position inside a 1.2 T electromagnet, and has achieved over 75% 3He polarisation when fully optimized. This talk will describe the magnetic cavities, and laser sources as well as provide a description of the completed 3He polarizer devices.

  11. [Surgical results and monitoring of postoperative atrial myxomas].

    PubMed

    Tarelo-Saucedo, Juan M; Peñaloza-Guadarrama, Mario; Villela-Caleti, Jorge; García-Cruz, Adriana; Arizmendi-Monroy, Dulce K; Reynada-Torres, Jose L; Martinez-Ramirez, Leonel

    2016-01-01

    To analyze the casuistics of left atrial myxoma with emphasis on results and follow-up. We reviewed the clinical records of patients operated in the Hospital Cardiac Myxomas South Central High Specialty (HCSAE) of PEMEX in the last 7 years, with an emphasis on results and follow-up. The analysis showed 10 patients, of whom 60% were female and 40% male, with ages from 12 to 76 years, with a mean age of 50 years. In the clinical characteristics of patients predominated dyspnea in 90%, followed by fatigue (80%) and chest pain (60%). The incidence was 90% for the left atrium and 10% for the right atrium, had tumors less than 3cm to up to over 10cm (average of 6 to 7cm). The pathology report was myxoma in the 100% of cases, the morbidity and early mortality was 0%, with a mean hospital stay of 6 days, and a patient of 12 years of age recurred and underwent surgery five months later. The 5-year survival was 100%. The incidence of myxomas is well known for rare presentation, the experience in this national medical center is one patient for every 350 operations, one case per year with no mortality and excellent survival. Copyright © 2015 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  12. Planar Microwave Sensor for Theranostic Therapy of Organic Tissue Based on Oval Split Ring Resonators

    PubMed Central

    Reimann, Carolin; Puentes, Margarita; Maasch, Matthias; Hübner, Frank; Bazrafshan, Babak; Vogl, Thomas J.; Damm, Christian; Jakoby, Rolf

    2016-01-01

    Microwave sensors in medical environments play a significant role due to the contact-less and non-invasive sensing mechanism to determine dielectric properties of tissue. In this work, a theranostic sensor based on Split Ring Resonators (SRRs) is presented that provides two operation modes to detect and treat tumor cells, exemplary in the liver. For the detection mode, resonance frequency changes due to abnormalities are evaluated, and in the treatment mode, microwave ablation is performed. The planar sensor structure can be integrated into a needle like a surgery tool that evokes challenges concerning size limitations and biocompatibility. To meet the size requirements and provide a reasonable operating frequency, properties of oval shaped SRRs are investigated. By elongating the radius of the SRR in one direction, the resonance frequency can be decreased significantly compared to circular SRR by a factor of two below 12 GHz. In order to validate the detection and treatment characteristics of the sensor, full wave simulations and measurements are examined. Clear resonance shifts are detected for loading the sensor structures with phantoms mimicking healthy and malignant tissue. For treatment mode evaluation, ex vivo beef liver tissue was ablated leading to a lesion zone 1.2 cm × 1 cm × 0.3 cm with a three minute exposure of maximum 2.1 W. PMID:27618050

  13. Sterilization of Surfaces with a Handheld Atmospheric Pressure Plasma

    NASA Astrophysics Data System (ADS)

    Hicks, Robert; Habib, Sara; Chan, Wai; Gonzalez, Eleazar; Tijerina, A.; Sloan, Mark

    2009-10-01

    Low temperature, atmospheric pressure plasmas have shown great promise for decontaminating the surfaces of materials and equipment. In this study, an atmospheric pressure, oxygen and argon plasma was investigated for the destruction of viruses, bacteria, and spores. The plasma was operated at an argon flow rate of 30 L/min, an oxygen flow rate of 20 mL/min, a power density of 101.0 W/cm^3 (beam area = 5.1 cm^2), and at a distance from the surface of 7.1 mm. An average 6log10 reduction of viable spores was obtained after only 45 seconds of exposure to the reactive gas. By contrast, it takes more than 35 minutes at 121^oC to sterilize anthrax in an autoclave. The plasma properties were investigated by numerical modeling and chemical titration with nitric oxide. The numerical model included a detailed reaction mechanism for the discharge as well as for the afterglow. It was predicted that at a delivered power density of 29.3 W/cm^3, 30 L/min argon, and 0.01 volume% O2, the plasma generated 1.9 x 10^14 cm-3 O atoms, 1.6 x 10^12 cm-3 ozone, 9.3 x 10^13 cm-3 O2(^1δg), and 2.9 x 10^12 cm-3 O2(^1σ^+g) at 1 cm downstream of the source. The O atom density measured by chemical titration with NO was 6.0 x 10^14 cm-3 at the same conditions. It is believe that the oxygen atoms and the O2(^1δg) metastables were responsible for killing the anthrax and other microorganisms.

  14. Flexible Ureterorenoscopy versus Mini-Percutaneous Nephrolithotomy for the Treatment of Renal Stones.

    PubMed

    Ergin, Giray; Kirac, Mustafa; Kopru, Burak; Ebiloglu, Turgay; Biri, Hasan

    2018-04-22

    To compare the pain status and stone free rates of flexible ureterorenoscopy (F-URS) versus mini-percutaneousnephrolithotomy (mini-PNL) for the treatment of 1-to 2-cm renal stones. This study was retrospectively designed with match paired method. Between January 2013 and December 2016, 387 patients underwent stone surgery for renal stones, 45 patients underwent FURS and 45 patients underwent mini-PNL. 90 patients were divided into two groups according to the surgical procedures. Group 1 patients underwent F-URS, and Group 2 patients underwent mini-PNL. During the intraoperative andpostoperative periods, pain management for all patients was standardized. Pain scores were determined using a visual analogue scale (VAS) completed at 2, 6, 12 and 24 hours postoperatively. The stone free status, hemoglobin levels, fluoroscopy time (FT), operation time (OT), hospitalization time (HT), return to work time (RWT), and complications were noted for each patient. Of all patients, the mean age was 41.1 ± 12.1 years and the mean stone size was 13.9 ± 2.9 mm. The VAS scores were significantly higher in the mini-PNL group at 2, 6, 12 and 24 hours (P < .05). The stone-free status and complication rates were similar between the two groups (P > .05); however, the hemoglobin decreases and the fluoroscopy, operation, hospitalization and return to work times were higher in the mini-PNL group than in the F-URS group (P < .05). F-URS is less painful than mini-PNL for the treatment of 1- to 2-cm renal stones. However, the stone free rate is similar between the two procedures while mini-PNL is superior in terms of fluoroscopy, operation, hospitalization and return to work duration. We think that F-URS is more comfortable and less painful than mini-PNL and achieves a similar stone free rate for the treatment of 1- to 2-cm renal stones.

  15. Virtual Microscope Views of the Apollo 11, 12, and 15 Lunar Samples

    NASA Technical Reports Server (NTRS)

    Gibson, E. K.; Tindle, A. G.; Kelley, S. P.; Pillinger, J. M.

    2017-01-01

    The Apollo virtual microscope is a means of viewing, over the Internet, polished thin sections of every rock in the Apollo lunar sample collections. It uses software that duplicates many of the functions of a petrological microscope.

  16. Evaluation of breast tissue with confocal strip-mosaicking microscopy: a test approach emulating pathology-like examination

    PubMed Central

    Abeytunge, Sanjee; Larson, Bjorg; Peterson, Gary; Morrow, Monica; Rajadhyaksha, Milind

    2017-01-01

    Abstract. Confocal microscopy is an emerging technology for rapid imaging of freshly excised tissue without the need for frozen- or fixed-section processing. Initial studies have described imaging of breast tissue using fluorescence confocal microscopy with small regions of interest, typically 750×750  μm2. We present exploration with a microscope, termed confocal strip-mosaicking microscope (CSM microscope), which images an area of 2×2  cm2 of tissue with cellular-level resolution in 10 min of excision. Using the CSM microscope, we imaged 34 fresh, human, large breast tissue specimens from 18 patients, blindly analyzed by a board-certified pathologist and subsequently correlated with the corresponding standard fixed histopathology. Invasive tumors and benign tissue were clearly identified in CSM strip-mosaic images. Thirty specimens were concordant for image-to-histopathology correlation while four were discordant. PMID:28327961

  17. Compact scanning tunneling microscope for spin polarization measurements.

    PubMed

    Kim, Seong Heon; de Lozanne, Alex

    2012-10-01

    We present a design for a scanning tunneling microscope that operates in ultrahigh vacuum down to liquid helium temperatures in magnetic fields up to 8 T. The main design philosophy is to keep everything compact in order to minimize the consumption of cryogens for initial cool-down and for extended operation. In order to achieve this, new ideas were implemented in the design of the microscope body, dewars, vacuum chamber, manipulators, support frame, and vibration isolation. After a brief description of these designs, the results of initial tests are presented.

  18. High Electron Mobility Transistor Structures on Sapphire Substrates Using CMOS Compatible Processing Techniques

    NASA Technical Reports Server (NTRS)

    Mueller, Carl; Alterovitz, Samuel; Croke, Edward; Ponchak, George

    2004-01-01

    System-on-a-chip (SOC) processes are under intense development for high-speed, high frequency transceiver circuitry. As frequencies, data rates, and circuit complexity increases, the need for substrates that enable high-speed analog operation, low-power digital circuitry, and excellent isolation between devices becomes increasingly critical. SiGe/Si modulation doped field effect transistors (MODFETs) with high carrier mobilities are currently under development to meet the active RF device needs. However, as the substrate normally used is Si, the low-to-modest substrate resistivity causes large losses in the passive elements required for a complete high frequency circuit. These losses are projected to become increasingly troublesome as device frequencies progress to the Ku-band (12 - 18 GHz) and beyond. Sapphire is an excellent substrate for high frequency SOC designs because it supports excellent both active and passive RF device performance, as well as low-power digital operations. We are developing high electron mobility SiGe/Si transistor structures on r-plane sapphire, using either in-situ grown n-MODFET structures or ion-implanted high electron mobility transistor (HEMT) structures. Advantages of the MODFET structures include high electron mobilities at all temperatures (relative to ion-implanted HEMT structures), with mobility continuously improving to cryogenic temperatures. We have measured electron mobilities over 1,200 and 13,000 sq cm/V-sec at room temperature and 0.25 K, respectively in MODFET structures. The electron carrier densities were 1.6 and 1.33 x 10(exp 12)/sq cm at room and liquid helium temperature, respectively, denoting excellent carrier confinement. Using this technique, we have observed electron mobilities as high as 900 sq cm/V-sec at room temperature at a carrier density of 1.3 x 10(exp 12)/sq cm. The temperature dependence of mobility for both the MODFET and HEMT structures provides insights into the mechanisms that allow for enhanced electron mobility as well as the processes that limit mobility, and will be presented.

  19. Reflectance confocal microscopy of optical phantoms

    PubMed Central

    Jacques, Steven L.; Wang, Bo; Samatham, Ravikant

    2012-01-01

    A reflectance confocal scanning laser microscope (rCSLM) operating at 488-nm wavelength imaged three types of optical phantoms: (1) 100-nm-dia. polystyrene microspheres in gel at 2% volume fraction, (2) solid polyurethane phantoms (INO BiomimicTM), and (3) common reflectance standards (SpectralonTM). The noninvasive method measured the exponential decay of reflected signal as the focus (zf) moved deeper into the material. The two experimental values, the attenuation coefficient μ and the pre-exponential factor ρ, were mapped into the material optical scattering properties, the scattering coefficient μs and the anisotropy of scattering g. Results show that μs varies as 58, 8–24, and 130–200 cm-1 for phantom types (1), (2) and (3), respectively. The g varies as 0.112, 0.53–0.67, and 0.003–0.26, respectively. PMID:22741065

  20. The effect of incremental distal gastric myotomy lengths on EGJ distensibility during POEM for achalasia

    PubMed Central

    Teitelbaum, Ezra N.; Sternbach, Joel M.; Khoury, Rym El; Soper, Nathaniel J.; Pandolfino, John E.; Kahrilas, Peter J.; Lin, Zhiyue; Hungness, Eric S.

    2015-01-01

    Background During peroral esophageal myotomy (POEM) for the treatment of achalasia, the optimal distal gastric myotomy length is unknown. In this study we used a functional lumen imaging probe (FLIP) to intraoperatively measure the effect of variable distal myotomy lengths on esophagogastric junction (EGJ) distensibility. Methods EGJ distensibility index (DI) (minimum cross-sectional area divided by intra-bag pressure) was measured with FLIP after each operative step. Each patient's myotomy was performed in four increments from proximal to distal: 1) an esophageal myotomy (from 6cm proximal to the EGJ, to 1cm proximal to it), 2) a myotomy ablating the lower esophageal sphincter (LES) complex (from 1cm proximal to the EGJ, to 1cm distal to it), 3) an initial gastric extension (from 1cm distal to the EGJ, to 2cm distal), and 4) a final gastric extension (from 2cm distal to the EGJ, to 3cm distal). Results Measurements were performed in 16 achalasia patients during POEM. POEM resulted in an overall increase in DI (pre 1.2 vs. post 7.2 mm2/mmHg, p<.001). Initial creation of the submucosal tunnel resulted in a 3-fold increase in DI (1.2 vs. 3.6 mm2/mmHg, p<.001). When the myotomy was then performed in a stepwise fashion from proximal to distal, the initial esophageal myotomy component had no effect on DI. Subsequent myotomy extension across the LES complex resulted in an increase in DI, as did the initial gastric myotomy extension (to 2cm distal to the EGJ). The final gastric myotomy extension (to 3cm distal) had no further effect. Conclusions During POEM, creation of the submucosal tunnel prior to myotomy resulted in a marked improvement in EGJ physiology. Myotomy extension across the LES complex and to 2cm onto the gastric wall resulted in normalization of EGJ distensibility, whereas subsequent extension to 3cm distal to the EGJ did not increase compliance further. PMID:26092005

  1. Integrated system for point cloud reconstruction and simulated brain shift validation using tracked surgical microscope

    NASA Astrophysics Data System (ADS)

    Yang, Xiaochen; Clements, Logan W.; Luo, Ma; Narasimhan, Saramati; Thompson, Reid C.; Dawant, Benoit M.; Miga, Michael I.

    2017-03-01

    Intra-operative soft tissue deformation, referred to as brain shift, compromises the application of current imageguided surgery (IGS) navigation systems in neurosurgery. A computational model driven by sparse data has been used as a cost effective method to compensate for cortical surface and volumetric displacements. Stereoscopic microscopes and laser range scanners (LRS) are the two most investigated sparse intra-operative imaging modalities for driving these systems. However, integrating these devices in the clinical workflow to facilitate development and evaluation requires developing systems that easily permit data acquisition and processing. In this work we present a mock environment developed to acquire stereo images from a tracked operating microscope and to reconstruct 3D point clouds from these images. A reconstruction error of 1 mm is estimated by using a phantom with a known geometry and independently measured deformation extent. The microscope is tracked via an attached tracking rigid body that facilitates the recording of the position of the microscope via a commercial optical tracking system as it moves during the procedure. Point clouds, reconstructed under different microscope positions, are registered into the same space in order to compute the feature displacements. Using our mock craniotomy device, realistic cortical deformations are generated. Our experimental results report approximately 2mm average displacement error compared with the optical tracking system. These results demonstrate the practicality of using tracked stereoscopic microscope as an alternative to LRS to collect sufficient intraoperative information for brain shift correction.

  2. Wide-band acousto-optic deflectors for large field of view two-photon microscope.

    PubMed

    Jiang, Runhua; Zhou, Zhenqiao; Lv, Xiaohua; Zeng, Shaoqun

    2012-04-01

    Acousto-optic deflector (AOD) is an attractive scanner for two-photon microscopy because it can provide fast and versatile laser scanning and does not involve any mechanical movements. However, due to the small scan range of available AOD, the field of view (FOV) of the AOD-based microscope is typically smaller than that of the conventional galvanometer-based microscope. Here, we developed a novel wide-band AOD to enlarge the scan angle. Considering the maximum acceptable acoustic attenuation in the acousto-optic crystal, relatively lower operating frequencies and moderate aperture were adopted. The custom AOD was able to provide 60 MHz 3-dB bandwidth and 80% peak diffraction efficiency at 840 nm wavelength. Based on a pair of such AOD, a large FOV two-photon microscope was built with a FOV up to 418.5 μm (40× objective). The spatiotemporal dispersion was compensated simultaneously with a single custom-made prism. By means of dynamic power modulation, the variation of laser intensity within the FOV was reduced below 5%. The lateral and axial resolution of the system were 0.58-2.12 μm and 2.17-3.07 μm, respectively. Pollen grain images acquired by this system were presented to demonstrate the imaging capability at different positions across the entire FOV. © 2012 American Institute of Physics

  3. Single-photon counting multicolor multiphoton fluorescence microscope.

    PubMed

    Buehler, Christof; Kim, Ki H; Greuter, Urs; Schlumpf, Nick; So, Peter T C

    2005-01-01

    We present a multicolor multiphoton fluorescence microscope with single-photon counting sensitivity. The system integrates a standard multiphoton fluorescence microscope, an optical grating spectrograph operating in the UV-Vis wavelength region, and a 16-anode photomultiplier tube (PMT). The major technical innovation is in the development of a multichannel photon counting card (mC-PhCC) for direct signal collection from multi-anode PMTs. The electronic design of the mC-PhCC employs a high-throughput, fully-parallel, single-photon counting scheme along with a high-speed electrical or fiber-optical link interface to the data acquisition computer. There is no electronic crosstalk among the detection channels of the mC-PhCC. The collected signal remains linear up to an incident photon rate of 10(8) counts per second. The high-speed data interface offers ample bandwidth for real-time readout: 2 MByte lambda-stacks composed of 16 spectral channels, 256 x 256 pixel image with 12-bit dynamic range can be transferred at 30 frames per second. The modular design of the mC-PhCC can be readily extended to accommodate PMTs of more anodes. Data acquisition from a 64-anode PMT has been verified. As a demonstration of system performance, spectrally resolved images of fluorescent latex spheres and ex-vivo human skin are reported. The multicolor multiphoton microscope is suitable for highly sensitive, real-time, spectrally-resolved three-dimensional imaging in biomedical applications.

  4. New Physics requirements and technological challenges to be confronted by calorimeters in particle physics

    NASA Astrophysics Data System (ADS)

    Cavallari, Francesca

    2015-09-01

    The seminar presents an introduction to calorimetry in particle physics. Initially the purpose of electromagnetic and hadronic calorimeters in particle physics is shown. Then the paper focusses on electromagnetic calorimeters and it describes the microscopic phenomena that drive the formation of electromagnetic showers. Homogeneous and sampling calorimeters are presented and the energy resolution of both is analyzed. A few examples of past and present electromagnetic calorimeters at particle colliders are presented, with particular attention to the ones employed in the Atlas and CMS experiments at the LHC, their design constraints, challenges and adopted choices. Both these calorimeters were designed to operate for a minimum of ten years at the LHC, with an instantaneous luminosity of 1· 1034/cm2/s and for an integrated luminosity of 500/fb. From 2023 a new program will start: the high luminosity LHC (HL-LHC), which is expected to provide an instantaneous luminosity of around 5· 1034/cm2/s and integrate a total luminosity of around 3000/fb in ten years of data taking. The evolution of the CMS and Atlas calorimeters is assessed and needed upgrades are presented.

  5. Ge photocapacitive MIS infrared detectors

    NASA Technical Reports Server (NTRS)

    Binari, S. C.; Miller, W. E.; Tsuo, Y. H.; Miller, W. E.

    1979-01-01

    An undoped Ge photocapacitive detector is reported which has peak normalized detectivities at wavelengh 1.4 microns and chopping frequencies 13-1000 Hz of 9 x 10 to the 12th, 4 x 10 to the 9th cm Hz to the 1/2th/W operating respectively at temperatures 77, 195, and 295 K. The observed temperature, spectral, and frequency response of the signal and noise are explained in terms of the measured space charge and interface state properties of the device.

  6. Long lifetime hollow cathodes for 30-cm mercury ion thrusters

    NASA Technical Reports Server (NTRS)

    Mirtich, M. J.; Kerslake, W. R.

    1976-01-01

    An experimental investigation of hollow cathodes for 30-cm Hg bombardment thrusters was carried out. Both main and neutralizer cathode configurations were tested with both rolled foil inserts coated with low work function material and impregnated porous tungsten inserts. Temperature measurements of an impregnated insert at various positions in the cathode were made. These, along with the cathode thermal profile are presented. A theory for rolled foil and impregnated insert operation and lifetime in hollow cathodes is developed. Several endurance tests, as long as 18000 hours at emission currents of up to 12 amps were attained with no degradation in performance.

  7. CHAMP (Camera, Handlens, and Microscope Probe)

    NASA Technical Reports Server (NTRS)

    Mungas, Greg S.; Boynton, John E.; Balzer, Mark A.; Beegle, Luther; Sobel, Harold R.; Fisher, Ted; Klein, Dan; Deans, Matthew; Lee, Pascal; Sepulveda, Cesar A.

    2005-01-01

    CHAMP (Camera, Handlens And Microscope Probe)is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As a robotic arm-mounted imager, CHAMP supports stereo imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision rangefinding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. CHAMP was originally developed through the Mars Instrument Development Program (MIDP) in support of robotic field investigations, but may also find application in new areas such as robotic in-orbit servicing and maintenance operations associated with spacecraft and human operations. We overview CHAMP'S instrument performance and basic design considerations below.

  8. Chemistry and Microtextures of Melt Pockets in the Los Angeles Basaltic Shergottite

    NASA Astrophysics Data System (ADS)

    Walton, E. L.; Spray, J. G.

    2002-01-01

    Los Angeles is a non-brecciated, highly shocked basaltic shergottite. The shock effects in Los Angeles can be classified into two basic types: (1) mechanical deformations and transformations that take place essentially in the solid state, and (2) localized regions of shock melting forming glassy to microcrystal line enclaves. A brief description of the former type, based largely on optical observations, is given. The complete transformation of plagioclase to maskelynite, mosaicism and planar fracturing of clinopyroxenes, pyrrhotite veins within clinopyroxene, polycrystallinity of some pyrrhotite grains, and a 350 pinlong fault with approximately 15-micrometer displacement is described. These results are in agreement with this study. This work presents a detailed description of the shock-related microtexture and mineralogy of the localized melt pockets which have formed by in situ melting of local mineral phases. The melt pockets range from 3 mm x 3 min 0.07 mm x 1.25 mm, in direct contact with the host matrix. Two polished thin sections of stone 1 (1.3 cm x 1 cm, 2.1 cm x 1.2 cm) have been investigated to determine the mineralogy and microtextures of the shock-induced melt pockets using a JEOL 6400 digital scanning electron microscope equipped with a Link Analytical eXL energy dispersive spectrometer (EDS) fitted with a Si (Li) LZ-4 Pentafet detector, and a FEG-SEM equipped with the In-Lens Thermal FEG which produces high probe current sufficient for EBSP, WDS, and EDS. These instruments are capable of characterizing compositional variations and microtextures of the melt pockets that are unresolvable using optical techniques.

  9. Endometrioid Adenocarcinoma Arising in a Paratubal Cyst: A Case Report and Review of the Literature.

    PubMed

    Chang, Catherine; Matsuo, Koji; Mhawech-Fauceglia, Paulette

    2017-03-01

    A 56-year-old G3P3 postmenopausal woman presented with a 5 month history of abnormal uterine bleeding and pelvic pain. A computed tomographic scan revealed a 5 cm right adnexal cystic mass in addition to a thickened, heterogenous endometrium and leiomyomatous uterus. A total laparascopic hysterectomy and bilateral salpingo-oophorectomy with omental and peritoneal biopsy were performed. Gross examination revealed a 12 week size uterus with small fibroids, normal bilateral atrophic ovaries, and a right paratubal cyst. A 4 cm vegetating mass was found in the right side of the uterine wall. Microscopically, the uterine mass was diagnosed as an endometrioid adenocarcinoma (EAC) FIGO 1 with 70% of myometrial invasion. The remaining endometrium showed a complex atypical hyperplasia. In addition, a 5 cm paratubal cystic mass was found that was separate from the uterus and the right adnexa. The cyst content was a chocolate brown fluid and the cyst wall was smooth with a single solid mass of 2 cm in size. The diagnosis of EAC, FIGO 1 was given. The remaining cyst lining showed endometriotic cyst and foci of endometriosis in the cyst wall. There was no lymphovascular invasion. The entire fallopian tube and ovaries were submitted and they were free of tumor. The patient was diagnosed with primary EAC of the paratubal cyst in addition to EAC of the uterine corpus (pT1b). A close follow-up was recommended. Because of our limited knowledge of carcinomas arising in the paratubal cyst, we will review the literature and discuss their clinical aspects, management, and behavior.

  10. Measurements of the cesium flow from a surface-plasma H/sup -/ ion source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, H.V.; Allison, P.W.

    1979-01-01

    A surface ionization gauge (SIG) was constructed and used to measure the Cs/sup 0/ flow rate through the emission slit of a surface-plasma source (SPS) of H/sup -/ ions with Penning geometry. The equivalent cesium density in the SPS discharge is deduced from these flow measurements. For dc operation the optimum H/sup -/ current occurs at an equivalent cesium density of approx. 7 x 10/sup 12/ cm/sup -3/ (corresponding to an average cesium consumption rate of 0.5 mg/h). For pulsed operation the optimum H/sup -/ current occurs at an equivalent cesium density of approx. 2 x 10/sup 13/ cm/sup -3/more » (1-mg/h average cesium consumption rate). Cesium trapping by the SPS discharge was observed for both dc and pulsed operation. A cesium energy of approx. 0.1 eV is deduced from the observed time of flight to the SIG. In addition to providing information on the physics of the source, the SIG is a useful diagnostic tool for source startup and operation.« less

  11. Photodeposition of Ag2S on TiO2 nanorod arrays for quantum dot-sensitized solar cells

    PubMed Central

    2013-01-01

    Ag2S quantum dots were deposited on the surface of TiO2 nanorod arrays by a two-step photodeposition. The prepared TiO2 nanorod arrays as well as the Ag2S deposited electrodes were characterized by X-ray diffraction, scanning electron microscope, and transmission electron microscope, suggesting a large coverage of Ag2S quantum dots on the ordered TiO2 nanorod arrays. UV–vis absorption spectra of Ag2S deposited electrodes show a broad absorption range of the visible light. The quantum dot-sensitized solar cells (QDSSCs) based on these electrodes were fabricated, and the photoelectrochemical properties were examined. A high photocurrent density of 10.25 mA/cm2 with a conversion efficiency of 0.98% at AM 1.5 solar light of 100 mW/cm2 was obtained with an optimal photodeposition time. The performance of the QDSSC at different incident light intensities was also investigated. The results display a better performance at a lower incident light level with a conversion efficiency of 1.25% at 47 mW/cm2. PMID:23286551

  12. A comprehensive approach to decipher biological computation to achieve next generation high-performance exascale computing.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, Conrad D.; Schiess, Adrian B.; Howell, Jamie

    2013-10-01

    The human brain (volume=1200cm3) consumes 20W and is capable of performing > 10^16 operations/s. Current supercomputer technology has reached 1015 operations/s, yet it requires 1500m^3 and 3MW, giving the brain a 10^12 advantage in operations/s/W/cm^3. Thus, to reach exascale computation, two achievements are required: 1) improved understanding of computation in biological tissue, and 2) a paradigm shift towards neuromorphic computing where hardware circuits mimic properties of neural tissue. To address 1), we will interrogate corticostriatal networks in mouse brain tissue slices, specifically with regard to their frequency filtering capabilities as a function of input stimulus. To address 2), we willmore » instantiate biological computing characteristics such as multi-bit storage into hardware devices with future computational and memory applications. Resistive memory devices will be modeled, designed, and fabricated in the MESA facility in consultation with our internal and external collaborators.« less

  13. Morphoscopic analysis of experimentally produced bony wounds from low-velocity ballistic impact.

    PubMed

    Kieser, Jules A; Tahere, Joy; Agnew, Caitlin; Kieser, David C; Duncan, Warwick; Swain, Michael V; Reeves, Matthew T

    2011-12-01

    Understanding how bone behaves when subjected to ballistic impact is of critical importance for forensic questions, such as the reconstruction of shooting events. Yet the literature addressing microscopic anatomical features of gunshot wounds to different types of bone is sparse. Moreover, a biomechanical framework for describing how the complex architecture of bone affects its failure during such impact is lacking. The aim of this study was to examine the morphological features associated with experimental gunshot wounds in slaughtered pig ribs. We shot the 4th rib of 12 adult pigs with .22 mm subsonic bullets at close range (5 cm) and examined resultant wounds under the light microscope, scanning electron microscope SEM and micro tomograph μCT. In all cases there was a narrow shot channel followed by spall region, with evidence of plastic deformation with burnishing of the surface bone in the former, and brittle fracture around and through individual Haversian systems in the latter. In all but one case, the entrance wounds were characterized by superficially fractured cortical bone in the form of a well-defined collar, while the exit wounds showed delamination of the periosteum. Inorganic residue was evident in all cases, with electron energy dispersive spectroscopy EDS confirming the presence of carbon, phosphate, lead and calcium. This material appeared to be especially concentrated within the fractured bony collar at the entrance. We conclude that gunshot wounds in flat bones may be morphologically divided into a thin burnished zone at the entry site, and a fracture zone at the exit.

  14. Measurement of flow speed in the channels of novel threadlike structures on the surfaces of mammalian organs

    NASA Astrophysics Data System (ADS)

    Sung, Baeckkyoung; Kim, Min Su; Lee, Byung-Cheon; Yoo, Jung Sun; Lee, Sang-Hee; Kim, Youn-Joong; Kim, Ki-Woo; Soh, Kwang-Sup

    2008-02-01

    There have been several reports on novel threadlike structures (NTSs) on the surfaces of the internal organs of rats and rabbits since their first observation by Bonghan Kim in 1963. To confirm this novel circulatory function, it is necessary to observe the flow of liquid through the NTS as well as the structurally corroborating channels in the NTS. In this article, we report on the measurement of the flow speed of Alcian blue solution in the NTSs on the organ surfaces of rabbits, and we present electron microscopic images depicting the cribrous cross-section with channels. The speed was measured as 0.3 ± 0.1 mm/s, and the flow distance was up to 12 cm. The flow was unidirectional, and the phase contrast microscopic images showed that the NTSs were strongly stained with Alcian blue. The ultrastructure of the NTSs revealed by cryo-scanning electron microscopy and high-voltage electron microscopy showed that (1) there were cell-like bodies and globular clumps of matter inside the sinus of the channel with thin strands of segregated zones which is a microscopic evidence of the liquid flow, (2) the sinuses have wall structures surrounded with extracellular matrices of collagenous fibers, and (3) there exists a cribriform structure of sinuses. To understand the mechanism for the circulation, a quantitative analysis of the flow speed has been undertaken applying a simplified windkessel model. In this analysis, it was shown that the liquid flow through the NTSs could be due to peristaltic motion of the NTS itself.

  15. Surface, electrical and mechanical modifications of PMMA after implantation with laser produced iron plasma ions

    NASA Astrophysics Data System (ADS)

    Ahmed, Qazi Salman; Bashir, Shazia; Jalil, Sohail Abdul; Shabbir, Muhammad Kaif; Mahmood, Khaliq; Akram, Mahreen; Khalid, Ayesha; Yaseen, Nazish; Arshad, Atiqa

    2016-07-01

    Laser Produced Plasma (LPP) was employed as an ion source for the modifications in surface, electrical and mechanical properties of poly methyl (methacrylate) PMMA. For this purpose Nd:YAG laser (532 nm, 6 ns, 10 Hz) at a fluence of 12.7 J/cm2 was employed to generate Fe plasma. The fluence and energy measurements of laser produced Fe plasma ions were carried out by employing Thomson Parabola Technique in the presence of magnetic field strength of 0.5 T, using CR-39 as Solid State Nuclear Track Detector (SSNTD). It has been observed that ion fluence ejecting from ablated plasma was maximum at an angle of 5° with respect to the normal to the Fe target surface. PMMA substrates were irradiated with Fe ions of constant energy of 0.85 MeV at various ion fluences ranging from 3.8 × 106 ions/cm2 to 1.8 × 108 ions/cm2 controlled by varying laser pulses from 3000 to 7000. Optical microscope and Scanning Electron Microscope (SEM) were utilized for the analysis of surface features of irradiated PMMA. Results depicted the formation of chain scission, crosslinking, dendrites and star like structures. To explore the electrical behavior, four probe method was employed. The electrical conductivity of ion irradiated PMMA was increased with increasing ion fluence. The surface hardness was measured by shore D hardness tester and results showed the monotonous increment in surface hardness with increasing ion fluence. The increasing trend of surface hardness and electrical conductivity with increasing Fe ion fluence has been well correlated with the surface morphology of ion implanted PMMA. The temperature rise of PMMA surface due to Fe ion irradiation is evaluated analytically and comes out to be in the range of 1.72 × 104 to 1.82 × 104 K. The values of total Linear Energy Transfer (LET) or stopping power of 0.8 MeV Fe ions in PMMA is 61.8 eV/Å and their range is 1.34 μm evaluated by SRIM simulation.

  16. Ultra-high resolution water window x ray microscope optics design and analysis

    NASA Technical Reports Server (NTRS)

    Shealy, David L.; Wang, C.

    1993-01-01

    This project has been focused on the design and analysis of an ultra-high resolution water window soft-x-ray microscope. These activities have been accomplished by completing two tasks contained in the statement of work of this contract. The new results from this work confirm: (1) that in order to achieve resolutions greater than three times the wavelength of the incident radiation, it will be necessary to use spherical mirror surfaces and to use graded multilayer coatings on the secondary in order to accommodate the large variations of the angle of incidence over the secondary when operating the microscope at numerical apertures of 0.35 or greater; (2) that surface contour errors will have a significant effect on the optical performance of the microscope and must be controlled to a peak-to-valley variation of 50-100 A and a frequency of 8 periods over the surface of a mirror; and (3) that tolerance analysis of the spherical Schwarzschild microscope has been shown that the water window operations will require 2-3 times tighter tolerances to achieve a similar performance of operations with 130 A radiation. These results have been included in a manuscript included in the appendix.

  17. Field-Portable Pixel Super-Resolution Colour Microscope

    PubMed Central

    Greenbaum, Alon; Akbari, Najva; Feizi, Alborz; Luo, Wei; Ozcan, Aydogan

    2013-01-01

    Based on partially-coherent digital in-line holography, we report a field-portable microscope that can render lensfree colour images over a wide field-of-view of e.g., >20 mm2. This computational holographic microscope weighs less than 145 grams with dimensions smaller than 17×6×5 cm, making it especially suitable for field settings and point-of-care use. In this lensfree imaging design, we merged a colorization algorithm with a source shifting based multi-height pixel super-resolution technique to mitigate ‘rainbow’ like colour artefacts that are typical in holographic imaging. This image processing scheme is based on transforming the colour components of an RGB image into YUV colour space, which separates colour information from brightness component of an image. The resolution of our super-resolution colour microscope was characterized using a USAF test chart to confirm sub-micron spatial resolution, even for reconstructions that employ multi-height phase recovery to handle dense and connected objects. To further demonstrate the performance of this colour microscope Papanicolaou (Pap) smears were also successfully imaged. This field-portable and wide-field computational colour microscope could be useful for tele-medicine applications in resource poor settings. PMID:24086742

  18. Field-portable pixel super-resolution colour microscope.

    PubMed

    Greenbaum, Alon; Akbari, Najva; Feizi, Alborz; Luo, Wei; Ozcan, Aydogan

    2013-01-01

    Based on partially-coherent digital in-line holography, we report a field-portable microscope that can render lensfree colour images over a wide field-of-view of e.g., >20 mm(2). This computational holographic microscope weighs less than 145 grams with dimensions smaller than 17×6×5 cm, making it especially suitable for field settings and point-of-care use. In this lensfree imaging design, we merged a colorization algorithm with a source shifting based multi-height pixel super-resolution technique to mitigate 'rainbow' like colour artefacts that are typical in holographic imaging. This image processing scheme is based on transforming the colour components of an RGB image into YUV colour space, which separates colour information from brightness component of an image. The resolution of our super-resolution colour microscope was characterized using a USAF test chart to confirm sub-micron spatial resolution, even for reconstructions that employ multi-height phase recovery to handle dense and connected objects. To further demonstrate the performance of this colour microscope Papanicolaou (Pap) smears were also successfully imaged. This field-portable and wide-field computational colour microscope could be useful for tele-medicine applications in resource poor settings.

  19. Soft tissue volume augmentation by the use of collagen-based matrices in the dog mandible -- a histological analysis.

    PubMed

    Thoma, Daniel S; Hämmerle, Christoph H F; Cochran, David L; Jones, Archie A; Görlach, Christoph; Uebersax, Lorenz; Mathes, Stephanie; Graf-Hausner, Ursula; Jung, Ronald E

    2011-11-01

    The aim was to test, whether or not soft tissue volume augmentation with a specifically designed collagen matrix (CM), leads to ridge width gain in chronic ridge defects similar to those obtained by an autogenous subepithelial connective tissue graft (SCTG). In six dogs, soft tissue volume augmentation was performed by randomly allocating three treatment modalities to chronic ridge defects [CM, SCTG and sham-operated control (Control)]. Dogs were sacrificed at 28 (n = 3) and 84 days (n = 3). Descriptive histology and histomorphometric measurements were performed on non-decalcified sections. SCTG and CM demonstrated favourable tissue integration, and subsequent re-modelling over 84 days. The overall mean amount of newly formed soft tissue (NMT) plus bone (NB) amounted to 3.8 ± 1.2 mm (Control), 6.4 ± 0.9 mm (CM) and 7.2 ± 1.2 mm (SCTG) at 28 days. At 84 days, the mean NMT plus NB reached 2.4 ± 0.9 mm (Control), 5.6 ± 1.5 mm (CM) and 6.0 ± 2.1 mm (SCTG). Statistically significant differences were observed between CM/SCTG and Control at both time-points (p < 0.05). Within the limits of this animal model, the CM performed similar to the SCTG, based on histomorphometric outcomes combining NB and NMT. © 2011 John Wiley & Sons A/S.

  20. [Liposuction combined with lymphatico-venous anastomosis for treatment of secondary lymphedema of the lower limbs: a report of 49 cases].

    PubMed

    Chang, K; Xia, S; Sun, Y G; Xin, J F; Shen, W B

    2017-04-01

    Objective: To study the clinical effects of liposuction combined with lymphatico-venous anastomosis for treatment of secondary lymphedema of the lower limbs. Methods: A retrospective analysis was performed for 49 patients who had undergone liposuction combined with lymphatico-venous anastomosis to treat secondary lymphedema of the lower limbs at Department of Lymph Surgery, Beijing Shijitan Hospital from November 2013 to February 2015.All patients were female aging from 31 to 70 years with median age of (52±10)years.All patients had history of pelvic surgery.There were 32 cases with cervical carcinoma, 11 cases with endometrial cancer, 1 case with ovarian cancer who accepted radical hysterectomy, 2 cases with benign tumor who accepted resection, 2 cases accepted inguinal lymph node dissection, 1 case with rectal cancer accepted radical resection.There were 30 cases with history of radiation therapy and 23 cases with history of erysipelas recurrent((2.1±3.9)/year). The limb swelling degree in preoperative and postoperative patients was explored using one-way analysis of variance with replicate measures and paired sample t -test. Meanwhile the incidence of lymphogenous infection was used as an evaluation of operation efficacy. Results: The mean lower limb circumference difference at 7 days, 6 months and 12 months was (0.17±1.36)cm, (1.25±1.62)cm and(1.58±1.56)cm, respectively, which was significantly decreased compared with preoperative((4.92±2.16)cm) ( t =-5.712, -5.777, -5.765; all P <0.01). The mean lower limb volume difference at 7 days, 6 months and 12 months was (522±799)ml, (726±973)ml and (889±895)ml, respectively, which was significantly decreased compared with preoperative((2 729±1 335) ml)( t =-5.905, -6.093, -5.777; all P <0.01). The incidence of erysipelas was 0.0(0.0, 0.0)/6 months within 6 months after operation and 0.0(0.0, 0.0)/6 months within 6-12 months after operation, which was significantly lower than that before operation(0.0(0.0, 2.0)/year). The feeling of tightness and heaviness of the limb was significantly improved compared with preoperative. Conclusion: Liposuction combined with lymphatico-venous anastomosis is an effective method for the treatment of secondary lymphedema of the lower limbs.

  1. Training Medical Novices in Spinal Microsurgery: Does the Modality Matter? A Pilot Study Comparing Traditional Microscopic Surgery and a Novel Robotic Optoelectronic Visualization Tool

    PubMed Central

    Tubbs, R. Shane; Page, Jeni; Chapman, Alexandra; Burgess, Brittni; Laws, Tyler; Warren, Haylie; Oskouian, Rod J

    2016-01-01

    The operative microscope has been a staple instrument in the neurosurgical operating room over the last 50 years. With advances in optoelectronics, options such as robotically controlled high magnification have become available. Such robotically controlled optoelectronic systems may offer new opportunities in surgical technique and teaching. However, traditionally trained surgeons may find it hard to accept newer technologies due to an inherent bias emerging from their previous background. We, therefore, studied how a medically naïve population in a pilot study would meet set microsurgical goals in a cadaver experiment using either a conventional operative microscope or BrightMatter™ Servo system, ​a robotically controlled optoelectronic system (Synaptive Medical, Toronto, Ontario, Canada). We found that the relative ease in teaching medical novices with a robotically controlled optoelectronic system was more valuable when compared to using a modern-day surgical microscope. PMID:26973804

  2. Influence of reaction time on the structural, optical and electrical performance of copper antimony sulfide nanoparticles using solvothermal method

    NASA Astrophysics Data System (ADS)

    John, Bincy; Genifer Silvena, G.; Leo Rajesh, A.

    2018-05-01

    The less toxic and cost effective ternary Cu-Sb-S nanoparticles and thin films were synthesized and deposited using solvothermal and drop casting method. The reactions were carried out at different timings as 12-48 h, in steps of 12 h using ethylene glycol as solvent and polyvinylpyrrolidone (PVP) as surfactant. Systematic analysis revealed that due to the influence of different reaction time, significant and unique changes were occurring on the crystal structure, optical and electrical properties of the material. The synthesized nanopowders and deposited films were characterized by means of X-ray diffraction, Raman analysis, field emission scanning electron microscope with energy dispersive spectrometer, UV-Vis-NIR diffuse reflectance spectroscopy and hall measurement. XRD results showed that as the time increases crystallinity improves and phase transformation from chalcostibite to tetrahedrite occurs. The Optical performance revealed that the bandgap of nanoparticles were in the range of 1.21-1.49 eV. Hall measurements showed that the deposited Cu12Sb4S13 and CuSbS2 films exhibited p-type conductivity with carrier concentration ranging from 1016-1019 cm-3, indicating a promising p-type absorber material for photovoltaic applications.

  3. Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research

    NASA Astrophysics Data System (ADS)

    Bergeron, Mélanie; Cadorette, Jules; Tétrault, Marc-André; Beaudoin, Jean-François; Leroux, Jean-Daniel; Fontaine, Réjean; Lecomte, Roger

    2014-02-01

    The LabPET is an avalanche photodiode (APD) based digital PET scanner with quasi-individual detector read-out and highly parallel electronic architecture for high-performance in vivo molecular imaging of small animals. The scanner is based on LYSO and LGSO scintillation crystals (2×2×12/14 mm3), assembled side-by-side in phoswich pairs read out by an APD. High spatial resolution is achieved through the individual and independent read-out of an individual APD detector for recording impinging annihilation photons. The LabPET exists in three versions, LabPET4 (3.75 cm axial length), LabPET8 (7.5 cm axial length) and LabPET12 (11.4 cm axial length). This paper focuses on the systematic characterization of the three LabPET versions using two different energy window settings to implement a high-efficiency mode (250-650 keV) and a high-resolution mode (350-650 keV) in the most suitable operating conditions. Prior to measurements, a global timing alignment of the scanners and optimization of the APD operating bias have been carried out. Characteristics such as spatial resolution, absolute sensitivity, count rate performance and image quality have been thoroughly investigated following the NEMA NU 4-2008 protocol. Phantom and small animal images were acquired to assess the scanners' suitability for the most demanding imaging tasks in preclinical biomedical research. The three systems achieve the same radial FBP spatial resolution at 5 mm from the field-of-view center: 1.65/3.40 mm (FWHM/FWTM) for an energy threshold of 250 keV and 1.51/2.97 mm for an energy threshold of 350 keV. The absolute sensitivity for an energy window of 250-650 keV is 1.4%/2.6%/4.3% for LabPET4/8/12, respectively. The best count rate performance peaking at 362 kcps is achieved by the LabPET12 with an energy window of 250-650 keV and a mouse phantom (2.5 cm diameter) at an activity of 2.4 MBq ml-1. With the same phantom, the scatter fraction for all scanners is about 17% for an energy threshold of 250 keV and 10% for an energy threshold of 350 keV. The results obtained with two energy window settings confirm the relevance of high-efficiency and high-resolution operating modes to take full advantage of the imaging capabilities of the LabPET scanners for molecular imaging applications.

  4. Primary haemangiopericytoma in the pelvic cavity of a dog.

    PubMed

    Cho, H S; Park, N Y

    2006-05-01

    A 9-year-old female Yorkshire terrier with lameness of the hind leg was examined at the local animal hospital in Gwangju, Republic of Korea on March, 2004. The radiological findings revealed a mass between the urinary bladder and cervix of the uterus. The encapsulated pelvic mass, measuring 4.0 x 3.0 x 2.5 cm was surgically removed. Grossly, the mass was white and firm and microscopically showed a perivascular whorled pattern of spindle cells. By immunohistochemistry, tumour cells tested positive for vimentin and alpha-smooth muscle actin, and negative for desmin, S-100, lysozyme and cytokeratin. The tumour was diagnosed both histologically and immunohistochemically as a haemangiopericytoma. There were no signs of recurrence within 12 months after surgery. This is the first case report of a haemangiopericytoma in the pelvic cavity of a dog.

  5. Renal epithelioid angiomyolipoma with malignant features: Histological evaluation and novel immunohistochemical findings.

    PubMed

    Konosu-Fukaya, Sachiko; Nakamura, Yasuhiro; Fujishima, Fumiyoshi; Kasajima, Atsuko; McNamara, Keely M; Takahashi, Yayoi; Joh, Kensuke; Saito, Hideo; Ioritani, Naomasa; Ikeda, Yoshihiro; Arai, Yoichi; Watanabe, Mika; Sasano, Hironobu

    2014-03-01

    Renal epithelioid angiomyolipoma (EAML) is a potentially malignant tumor type whose characteristics and biomarkers predictive of malignant behavior have not been elucidated. Here, we report three cases of renal EAML with malignant features but without histories of tuberous sclerosis complex. Case 1 involved a 29-year-old man with a 12-cm solid mass in the right kidney who underwent radical right nephrectomy. Case 2 involved a 22-year-old woman with a retroperitoneal mass who underwent radical right nephrectomy and retroperitoneal tumorectomy. Local recurrence was detected 7 years post-surgery. Case 3 involved a 23-year-old man with a 14-cm solid mass in the left kidney who underwent radical left nephrectomy. Microscopically, the tumors in all cases demonstrated proliferation of epithelioid cells with atypia, mitotic activity, necrosis, hemorrhage, and vascular invasion. Epithelioid cells in all cases were immunohistochemically positive for melanocytic and myoid markers and weakly positive for E-cadherin and β-catenin. Immunohistochemistry revealed activation of the mammalian target of rapamycin pathway. Here, we report the morphological and immunohistochemical features of clinically or histologically malignant renal EAML. © 2014 The Authors. Pathology International © 2014 Japanese Society of Pathology and Wiley Publishing Asia Pty Ltd.

  6. Soft x-ray imaging with incoherent sources

    NASA Astrophysics Data System (ADS)

    Wachulak, P.; Torrisi, A.; Ayele, M.; Bartnik, A.; Czwartos, J.; Wegrzyński, Ł.; Fok, T.; Parkman, T.; Vondrová, Š.; Turnová, J.; Odstrcil, M.; Fiedorowicz, H.

    2017-05-01

    In this work we present experimental, compact desk-top SXR microscope, the EUV microscope which is at this stage a technology demonstrator, and finally, the SXR contact microscope. The systems are based on laser-plasma EUV and SXR sources, employing a double stream gas puff target. The EUV and SXR full field microscopes, operating at 13.8 nm and 2.88 nm wavelengths, respectively, are capable of imaging nanostructures with a sub-50 nm spatial resolution with relatively short (seconds) exposure times. The SXR contact microscope operates in the "water-window" spectral range, to produce an imprint of the internal structure of the sample in a thin layer of SXR light sensitive photoresist. Applications of such desk-top EUV and SXR microscopes for studies of variety of different samples - test objects for resolution assessment and other objects such as carbon membranes, DNA plasmid samples, organic and inorganic thin layers, diatoms, algae and carcinoma cells, are also presented. Details about the sources, the microscopes as well as the imaging results for various objects will be presented and discussed. The development of such compact imaging systems may be important to the new research related to biological, material science and nanotechnology applications.

  7. Transpubic posterior urethroplasty via perineal approach in children: a new technique.

    PubMed

    Orabi, Samir

    2012-08-01

    To evaluate a new technique of transpubic urethroplasty via perineal approach for management of pelvic fracture urethral distraction defects (PFUDD) in children. Of 78 children undergoing posterior urethroplasty for PFUDD, 12 (15.4%) had a short urethra that could not bridge the gap (>5 cm) for a tension-free anastomosis. Age ranged from 5.2 to 12 years (median = 8.5 years). The median distraction defect length was 4.8 cm (range 3.7-6.4 cm). For the latter group, the new technique of transpubic posterior urethroplasty via perineal approach was performed. The first follow-up visit was scheduled 1 month after suprapubic catheter removal. Radiological studies and uroflowmetry were repeated at 6-month intervals for 1 year and once yearly thereafter. Patients were followed up for a period of 6 months to 5 years with a mean of 2.7 years. Mean operative time was 2.5 h (range 1.9-3.2 h) with a mean blood loss of 200 ml (range 50-640 cc) and the mean hospital stay was 4 days. All 12 children had a good urinary stream over the follow-up period; 3/12 (25%) developed stress urinary incontinence that resolved within 6 months postoperatively; 9/12 (75%) complained of (retracted) short penis. Transpubic urethroplasty via perineal approach is a feasible technique for management of complex PFUDD in children, and presents many advantages over other routes. Copyright © 2011 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  8. Characterization of exposures to airborne nanoscale particles during friction stir welding of aluminum.

    PubMed

    Pfefferkorn, Frank E; Bello, Dhimiter; Haddad, Gilbert; Park, Ji-Young; Powell, Maria; McCarthy, Jon; Bunker, Kristin Lee; Fehrenbacher, Axel; Jeon, Yongho; Virji, M Abbas; Gruetzmacher, George; Hoover, Mark D

    2010-07-01

    Friction stir welding (FSW) is considered one of the most significant developments in joining technology over the last half century. Its industrial applications are growing steadily and so are the number of workers using this technology. To date, there are no reports on airborne exposures during FSW. The objective of this study was to investigate possible emissions of nanoscale (<100 nm) and fine (<1 microm) aerosols during FSW of two aluminum alloys in a laboratory setting and characterize their physicochemical composition. Several instruments measured size distributions (5 nm to 20 microm) with 1-s resolution, lung deposited surface areas, and PM(2.5) concentrations at the source and at the breathing zone (BZ). A wide range aerosol sampling system positioned at the BZ collected integrated samples in 12 stages (2 nm to 20 microm) that were analyzed for several metals using inductively coupled plasma mass spectrometry. Airborne aerosol was directly collected onto several transmission electron microscope grids and the morphology and chemical composition of collected particles were characterized extensively. FSW generates high concentrations of ultrafine and submicrometer particles. The size distribution was bimodal, with maxima at approximately 30 and approximately 550 nm. The mean total particle number concentration at the 30 nm peak was relatively stable at approximately 4.0 x 10(5) particles cm(-3), whereas the arithmetic mean counts at the 550 nm peak varied between 1500 and 7200 particles cm(-3), depending on the test conditions. The BZ concentrations were lower than the source concentrations by 10-100 times at their respective peak maxima and showed higher variability. The daylong average metal-specific concentrations were 2.0 (Zn), 1.4 (Al), and 0.24 (Fe) microg m(-3); the estimated average peak concentrations were an order of magnitude higher. Potential for significant exposures to fine and ultrafine aerosols, particularly of Al, Fe, and Zn, during FSW may exist, especially in larger scale industrial operations.

  9. Optical Analysis of an Ultra-High resolution Two-Mirror Soft X-Ray Microscope

    NASA Technical Reports Server (NTRS)

    Shealy, David L.; Wang, Cheng; Hoover, Richard B.

    1994-01-01

    This work has summarized for a Schwarzschild microscope some relationships between numerical aperture (NA), magnification, diameter of the primary mirror, radius of curvature of the secondary mirror, and the total length of the microscope. To achieve resolutions better than a spherical Schwarzschild microscope of 3.3 Lambda for a perfectly aligned and fabricated system. it is necessary to use aspherical surfaces to control higher-order aberrations. For an NA of 0.35, the aspherical Head microscope provides diffraction limited resolution of 1.4 Lambda where the aspherical surfaces differ from the best fit spherical surface by approximately 1 micrometer. However, the angle of incidence varies significantly over the primary and the secondary mirrors, which will require graded multilayer coatings to operate near peak reflectivities. For higher numerical apertures, the variation of the angle of incidence over the secondary mirror surface becomes a serious problem which must be solved before multilayer coatings can be used for this application. Tolerance analysis of the spherical Schwarzschild microscope has shown that water window operations will require 2-3 times tighter tolerances to achieve a similar performance for operations with 130 A radiation. Surface contour errors have been shown to have a significant impact on the MTF and must be controlled to a peak-to-valley variation of 50-100 A and a frequency of 8 periods over the surface of a mirror.

  10. Efficacy and safety of non-suture dural closure using a novel dural substitute consisting of polyglycolic acid felt and fibrin glue to prevent cerebrospinal fluid leakage-A non-controlled, open-label, multicenter clinical trial.

    PubMed

    Terasaka, Shunsuke; Taoka, Toshiaki; Kuroda, Satoshi; Mikuni, Nobutaka; Nishi, Toru; Nakase, Hiroyuki; Fujii, Yukihiko; Hayashi, Yasuhiko; Murata, Jun-Ichi; Kikuta, Ken-Ichiro; Kuroiwa, Toshihiko; Shimokawa, Sachie; Houkin, Kiyohiro

    2017-05-01

    The objective of this study is to evaluate the efficacy and safety of non-suture dural closure using a novel dural substitute (GM111) consisting of polyglycolic acid felt with a fibrin-glue-coated area commensurate in size with the dural defect. This was a non-controlled, open-label, multicenter clinical trial. The efficacy evaluation endpoints were (1) GM111's intra-operative capability to close dural defects and (2) prevention of cerebrospinal fluid (CSF) leakage and subcutaneous CSF retention throughout the postoperative period (evaluated by diagnostic imaging). Patients meeting the following three preoperative and two intra-operative selection criteria were enrolled: (1) between 12 and <75 years of age; (2) the dura is surmised to be defective and in need of reconstruction; (3) informed written consent was obtained from the patient; (4) the surgical wound is class 1; and (5) the size of duraplasty is ≥0.2 cm 2 to <100 cm 2 . Sixty patients were enrolled. The craniotomy site was supratentorial in 77.2%, infratentorial in 12.3% and sellar in 10.5%. The GM111 prosthesis size ranged from 0.24 to 42 cm 2 . To evaluate the efficacy, intra-operative closure was confirmed by Valsalva's maneuver, water infusion, etc., in all patients. CSF leakage and subcutaneous CSF retention throughout the postoperative period were found in four patients. Adverse events for which a causal relationship with GM111 could not be ruled out occurred in 8.8% of the patients. There were no instances of postoperative infection due to GM111. GM111 showed good closure capability and safety when used for non-suture dural closure.

  11. Flow-Through Free Fibula Osteocutaneous Flap in Reconstruction of Tibial Bone, Soft Tissue, and Main Artery Segmental Defects.

    PubMed

    Li, Zonghuan; Yu, Aixi; Qi, Baiwen; Pan, Zhenyu; Ding, Junhui

    2017-08-01

    The aim of this report was to present the use of flow-through free fibula osteocutaneous flap for the repair of complex tibial bone, soft tissue, and main artery segmental defects. Five patients with bone, soft tissue, and segmental anterior tibial artery defects were included. The lengths of injured tibial bones ranged from 4 to 7 cm. The sizes of impaired soft tissues were between 9 × 4 and 15 × 6 cm. The lengths of defect of anterior tibial artery segments ranged from 6 to 10 cm. Two patients had distal limb perfusion problems. Flow-through free fibula osteocutaneous flap was performed for all 5 patients. Patients were followed for 12 to 18 months. All wounds healed after 1-stage operation, and all flow-through flaps survived. The distal perfusion after vascular repair was normal in all patients. Superficial necrosis of flap edge was noted in 1 case. After the local debridement and partial thickness skin graft, the flap healed uneventfully, and the surgical operation did not increase injury to the donor site. Satisfactory bone union was achieved in all patients in 2 to 4 months postoperation. Enlargement of fibula graft was observed during follow-up from 12 to 18 months. The functions of adjacent joints were recovered, and all patients were able to walk normally. Flow-through free fibula osteocutaneous flap was shown to be an effective and efficient technique for repairing composite tibial bone, soft tissue, and main artery segmental defects. This 1-stage operation should be useful in clinical practice for the treatment of complex bone, soft tissue, and vessel defects.

  12. Small stack performance of intermediate temperature-operating solid oxide fuel cells using stainless steel interconnects and anode-supported single cell

    NASA Astrophysics Data System (ADS)

    Bae, Joongmyeon; Lim, Sungkwang; Jee, Hyunjin; Kim, Jung Hyun; Yoo, Young-Sung; Lee, Taehee

    We are developing 1 kW class solid oxide fuel cell (SOFC) system for residential power generation (RPG) application supported by Korean Government. Anode-supported single cells with thin electrolyte layer of YSZ (yttria-stabilized zirconia) or ScSZ (scandia-stabilized zirconia) for intermediate temperature operation (650-750 °C), respectively, were fabricated and small stacks were built and evaluated. The LSCF/ScSZ/Ni-YSZ single cell showed performance of 543 mW cm -2 at 650 °C and 1680 mW cm -2 at 750 °C. The voltage of 15-cell stack based on 5 cm × 5 cm single cell (LSM/YSZ/Ni-YSZ) at 150 mW was 12.5 V in hydrogen as fuel of 120 sccm per cell at 750 °C and decreased to about 10.9 V at 500 h operation time. A 5-cell stack based on the LSCF/YSZ/FL/Ni-YSZ showed the maximum power density of 30 W, 25 W and 20 W at 750 °C, 700 °C and 650 °C, respectively. LSCF/ScSZ/Ni-YSZ-based stack showed better performance than LSCF/YSZ/Ni-YSZ stack from the experiment temperature range. I- V characteristics by using hydrogen gas and reformate gas of methane as fuel were investigated at 750 °C in LSCF/ScSZ/FL/Ni-YSZ-based 5-cell stack.

  13. Studies of a plasma with a hot dense core in LAPD

    NASA Astrophysics Data System (ADS)

    van Compernolle, Bart; Gekelman, Walter; Pribyl, Patrick; Cooper, Chris

    2009-11-01

    Recently, considerable effort in the LArge Plasma Device at UCLA (LAPD) has gone into the study of large cathodes which would enable higher discharge currents and higher densities. The new cathode is made out of Lanthanum HexaBoride (LaB6). LaB6 has a low work function and has higher emissivity than Barium oxide coated cathodes. The operating temperature of LaB6 cathodes lies above 1600 degrees Celsius. Tests of this cathode in the Enormous Toroidal Plasma Device (ETPD) showed that densities in excess of 2 10^13 cm-3 and electron temperatures of 12 eV are feasible. Small LaB6 cathodes (3mm - 2cm) have been used before in LAPD in several experiments on heat transport and on magnetized flux ropes. The cathode presented in this paper has a 8 cm diameter, and can be positioned at different radial locations. The cathode will be pulsed into the standard background plasma (ne= 2 10^12 cm-3, .25 <=Te<=6 eV, dia = 60 cm, L = 18 m) creating a plasma with a hot dense core. We present the characterization of the core plasma at different conditions. Studies of the heat transport and density spreading at the interface between the core plasma and background plasma will be done by use of a variety of probes (Langmuir, magnetic, Mach, emissive) as well as fast photography.

  14. Scanning tunneling microscope assembly, reactor, and system

    DOEpatents

    Tao, Feng; Salmeron, Miquel; Somorjai, Gabor A

    2014-11-18

    An embodiment of a scanning tunneling microscope (STM) reactor includes a pressure vessel, an STM assembly, and three spring coupling objects. The pressure vessel includes a sealable port, an interior, and an exterior. An embodiment of an STM system includes a vacuum chamber, an STM reactor, and three springs. The three springs couple the STM reactor to the vacuum chamber and are operable to suspend the scanning tunneling microscope reactor within the interior of the vacuum chamber during operation of the STM reactor. An embodiment of an STM assembly includes a coarse displacement arrangement, a piezoelectric fine displacement scanning tube coupled to the coarse displacement arrangement, and a receiver. The piezoelectric fine displacement scanning tube is coupled to the coarse displacement arrangement. The receiver is coupled to the piezoelectric scanning tube and is operable to receive a tip holder, and the tip holder is operable to receive a tip.

  15. Pollen characters of Firmiana malayana Kostem. (Malvaceae: Sterculoideae) in Malaysia

    NASA Astrophysics Data System (ADS)

    Amirul-Aiman, A. J.; Noraini, T.; Nurul-Aini, C. A. C.; Idris, S.; Suhaniza, R.

    2018-04-01

    Firmiana malayana also known as "Bullocks eye or Mata Lembu" in Malaysia and can be found along riverbanks and open forests in Peninsular Malaysia and seldom planted in populated areas. The flowers of the Firmiana malayana are vivid orange in colour, on tassels up to 12 cm long. Usually this species will shed its leaves after a dry period and remains bare for six to eight weeks. The objective of this study is to determine the pollen morphological characteristics of the Firmiana malayana in order to add more information on the species under the family of Sterculiaceae in Malaysia. Methods for this study includes acetolysis technique for the pollens and viewed under light microscope and scanning electron microscope. Results shown that the pollens of the species Firmiana malayana appeared to be monad and dyad with tricolporate class with both porate and colpus present. The shape of this species is prolate with P/E index of 1.49. This species was considered as medium-size pollens as the pollens ranges from 26 - 36 µm. The ornamentation of the pollen is reticulate where the ornamentation is network-like pattern formed by exine elements of lumen and murus. Based on the results obtained, pollen morphology is a great tool that can aid in plant identification and classification as well having taxonomic values.

  16. Variable-focus microscopy and UV surface dissolution imaging as complementary techniques in intrinsic dissolution rate determination.

    PubMed

    Ward, Adam; Walton, Karl; Box, Karl; Østergaard, Jesper; Gillie, Lisa J; Conway, Barbara R; Asare-Addo, Kofi

    2017-09-15

    This work reports a novel approach to the assessment of the surface properties of compacts used in Surface Dissolution Imaging (SDI). SDI is useful for determining intrinsic dissolution rate (IDR), an important parameter in early stage drug development. Surface topography, post-compaction and post-SDI run, have been measured using a non-contact, optical, three-dimensional microscope based on focus variation, the Alicona Infinite Focus Microscope, with the aim of correlating the IDRs to the surface properties. Ibuprofen (IBU) was used as a model poorly-soluble drug. DSC and XRD were used to monitor possible polymorphic changes that may have occurred post-compaction and post-SDI run. IBUs IDR decreased from 0.033mg/min/cm 2 to 0.022mg/min/cm 2 from 10 to 20min, respectively, during the experiment. XRD and DSC showed no form changes during the SDI run. The surface topography images showed that a distinct imprint was embossed on the surfaces of some compacts which could affect IDRs. Surface parameter values were associated with the SDI experiments which showed strong correlations with the IDR values. The variable-focus microscope can be used as a complimentary tool in the determination of IDR values from the SDI. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  17. Limited Margin Radiation Therapy for Children and Young Adults With Ewing Sarcoma Achieves High Rates of Local Tumor Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talleur, Aimee C.; Navid, Fariba; Spunt, Sheri L.

    Purpose: To determine the rate of local failure using focal conformal, limited margin radiation therapy (RT) and dose escalation for tumors ≥8 cm (greatest dimension at diagnosis) in children and young adults with Ewing sarcoma (EWS). Methods and Materials: Eligible patients with EWS were treated on a phase 2 institutional trial of focal conformal, limited margin RT using conformal or intensity modulated techniques. The treatment volume incorporated a 1-cm constrained margin around the gross tumor. Unresected tumors, <8 cm at diagnosis, received a standard dose of 55.8 Gy and tumors ≥8 cm, an escalated dose to 64.8 Gy. Patients with microscopic residual disease after resectionmore » received adjuvant RT to 50.4 Gy. Adjuvant brachytherapy was permitted in selected patients. Results: Forty-five patients were enrolled: 26 with localized and 19 with metastatic disease. Median (range) age, tumor size, and follow-up were 13.0 years (2.9-24.7 years), 9.0 cm (2.4-17.0 cm), and 54.5 months (1.9-122.2 months), respectively. All patients received systemic chemotherapy. The median (range) RT dose for all patients was 56.1 Gy (45-65.5 Gy). Seventeen patients received adjuvant, 16 standard-dose, and 12 escalated-dose RT. Failures included 1 local, 10 distant, and 1 local/distant. The estimated 10-year cumulative incidence of local failure was 4.4% ± 3.1%, with no statistical difference seen between RT treatment groups and no local failures in the escalated-dose RT treatment group. Conclusions: Treatment with focal conformal, limited margin RT, including dose escalation for larger tumors, provides favorable local tumor control in EWS.« less

  18. Intraoperative use of indocyanine green angiography for selecting the more reliable perforator of the anterolateral thigh flap: A comparison study.

    PubMed

    La Padula, Simone; Hersant, Barbara; Meningaud, Jean Paul

    2018-03-30

    Anatomical variability of anterolateral thigh flap (ALT) perforators has been reported. The aim of this study is to assess if the use of intraoperative indocyanine green angiography (iICGA) can help surgeons to choose the ALT flap best perforator to be preserved. A retrospective study was conducted in 28 patients with open tibial fracture, following a road traffic crash, who had undergone ALT flap. Patients were classified into two groups: ICGA group (iICGA was used to select the more reliable perforator) and control group. The mean tissue loss size of the ICGA group (n = 13, 11 men and 2 women, mean age: 52 ± 6 years) was of 16.6 cm × 12.2 cm. The mean defect size of the control group (n = 15, 14 men and 1 women, mean age: 50 ± 5.52 years) was of 15.3 cm × 11.1 cm. Statistical analysis was performed to analyze and compare the results. ICGA allowed preserving only the most functional perforator, that provided the best ALT flap perfusion in 10 out of the 13 cases (77%). ICGA allowed a significant operative time reduction (160 ± 23 vs. 202 ± 48 minutes; P < .001). One case of distal necrosis was observed in the ICGA group (mean follow-up 12.3 months), while partial skin necrosis occurred in three cases of the control group (mean follow-up 13.1 months); P = .35. No additional coverage was required and a successful bone healing was observed in both groups. These findings suggest that iICGA is an effective method that allows to select the most reliable ALT flap perforators and to reduce operative time. © 2018 Wiley Periodicals, Inc.

  19. Development of a clinical algorithm for treating urethral strictures based on a large retrospective single-center cohort

    PubMed Central

    Tolkach, Yuri; Herrmann, Thomas; Merseburger, Axel; Burchardt, Martin; Wolters, Mathias; Huusmann, Stefan; Kramer, Mario; Kuczyk, Markus; Imkamp, Florian

    2017-01-01

    Aim: To analyze clinical data from male patients treated with urethrotomy and to develop a clinical decision algorithm. Materials and methods: Two large cohorts of male patients with urethral strictures were included in this retrospective study, historical (1985-1995, n=491) and modern cohorts (1996-2006, n=470). All patients were treated with repeated internal urethrotomies (up to 9 sessions). Clinical outcomes were analyzed and systemized as a clinical decision algorithm. Results: The overall recurrence rates after the first urethrotomy were 32.4% and 23% in the historical and modern cohorts, respectively. In many patients, the second procedure was also effective with the third procedure also feasible in selected patients. The strictures with a length ≤ 2 cm should be treated according to the initial length. In patients with strictures ≤ 1 cm, the second session could be recommended in all patients, but not with penile strictures, strictures related to transurethral operations or for patients who were 31-50 years of age. The third session could be effective in selected cases of idiopathic bulbar strictures. For strictures with a length of 1-2 cm, a second operation is possible for the solitary low-grade bulbar strictures, given that the age is > 50 years and the etiology is not post-transurethral resection of the prostate. For penile strictures that are 1-2 cm, urethrotomy could be attempted in solitary but not in high-grade strictures. Conclusions: We present data on the treatment of urethral strictures with urethrotomy from a single center. Based on the analysis, a clinical decision algorithm was suggested, which could be a reliable basis for everyday clinical practice. PMID:28529689

  20. Multichannel FPGA-Based Data-Acquisition-System for Time-Resolved Synchrotron Radiation Experiments

    NASA Astrophysics Data System (ADS)

    Choe, Hyeokmin; Gorfman, Semen; Heidbrink, Stefan; Pietsch, Ullrich; Vogt, Marco; Winter, Jens; Ziolkowski, Michael

    2017-06-01

    The aim of this contribution is to describe our recent development of a novel compact field-programmable gatearray (FPGA)-based data acquisition (DAQ) system for use with multichannel X-ray detectors at synchrotron radiation facilities. The system is designed for time resolved counting of single photons arriving from several-currently 12-independent detector channels simultaneously. Detector signals of at least 2.8 ns duration are latched by asynchronous logic and then synchronized with the system clock of 100 MHz. The incoming signals are subsequently sorted out into 10 000 time-bins where they are counted. This occurs according to the arrival time of photons with respect to the trigger signal. Repeatable mode of triggered operation is used to achieve high statistic of accumulated counts. The time-bin width is adjustable from 10 ns to 1 ms. In addition, a special mode of operation with 2 ns time resolution is provided for two detector channels. The system is implemented in a pocketsize FPGA-based hardware of 10 cm × 10 cm × 3 cm and thus can easily be transported between synchrotron radiation facilities. For setup of operation and data read-out, the hardware is connected via USB interface to a portable control computer. DAQ applications are provided in both LabVIEW and MATLAB environments.

  1. Optical Coherence Tomography for Retinal Surgery: Perioperative Analysis to Real-Time Four-Dimensional Image-Guided Surgery.

    PubMed

    Carrasco-Zevallos, Oscar M; Keller, Brenton; Viehland, Christian; Shen, Liangbo; Seider, Michael I; Izatt, Joseph A; Toth, Cynthia A

    2016-07-01

    Magnification of the surgical field using the operating microscope facilitated profound innovations in retinal surgery in the 1970s, such as pars plana vitrectomy. Although surgical instrumentation and illumination techniques are continually developing, the operating microscope for vitreoretinal procedures has remained essentially unchanged and currently limits the surgeon's depth perception and assessment of subtle microanatomy. Optical coherence tomography (OCT) has revolutionized clinical management of retinal pathology, and its introduction into the operating suite may have a similar impact on surgical visualization and treatment. In this article, we review the evolution of OCT for retinal surgery, from perioperative analysis to live volumetric (four-dimensional, 4D) image-guided surgery. We begin by briefly addressing the benefits and limitations of the operating microscope, the progression of OCT technology, and OCT applications in clinical/perioperative retinal imaging. Next, we review intraoperative OCT (iOCT) applications using handheld probes during surgical pauses, two-dimensional (2D) microscope-integrated OCT (MIOCT) of live surgery, and volumetric MIOCT of live surgery. The iOCT discussion focuses on technological advancements, applications during human retinal surgery, translational difficulties and limitations, and future directions.

  2. Cleft Lip and Palate Repair Using a Surgical Microscope.

    PubMed

    Kato, Motoi; Watanabe, Azusa; Watanabe, Shoji; Utsunomiya, Hiroki; Yokoyama, Takayuki; Ogishima, Shinya

    2017-11-01

    Cleft lip and palate repair requires a deep and small surgical field and is usually performed by surgeons wearing surgical loupes. Surgeons with loupes can obtain a wider surgical view, although headlights are required for the deepest procedures. Surgical microscopes offer comfort and a clear and magnification-adjustable surgical site that can be shared with the whole team, including observers, and easily recorded to further the education of junior surgeons. Magnification adjustments are convenient for precise procedures such as muscle dissection of the soft palate. We performed a comparative investigation of 18 cleft operations that utilized either surgical loupes or microscopy. Paper-based questionnaires were completed by staff nurses to evaluate what went well and what could be improved in each procedure. The operating time, complication rate, and scores of the questionnaire responses were statistically analyzed. The operating time when microscopy was used was not significantly longer than when surgical loupes were utilized. The surgical field was clearly shared with surgical assistants, nurses, anesthesiologists, and students via microscope-linked monitors. Passing surgical equipment was easier when sharing the surgical view, and preoperative microscope preparation did not interfere with the duties of the staff nurses. Surgical microscopy was demonstrated to be useful during cleft operations.

  3. Optical Coherence Tomography for Retinal Surgery: Perioperative Analysis to Real-Time Four-Dimensional Image-Guided Surgery

    PubMed Central

    Carrasco-Zevallos, Oscar M.; Keller, Brenton; Viehland, Christian; Shen, Liangbo; Seider, Michael I.; Izatt, Joseph A.; Toth, Cynthia A.

    2016-01-01

    Magnification of the surgical field using the operating microscope facilitated profound innovations in retinal surgery in the 1970s, such as pars plana vitrectomy. Although surgical instrumentation and illumination techniques are continually developing, the operating microscope for vitreoretinal procedures has remained essentially unchanged and currently limits the surgeon's depth perception and assessment of subtle microanatomy. Optical coherence tomography (OCT) has revolutionized clinical management of retinal pathology, and its introduction into the operating suite may have a similar impact on surgical visualization and treatment. In this article, we review the evolution of OCT for retinal surgery, from perioperative analysis to live volumetric (four-dimensional, 4D) image-guided surgery. We begin by briefly addressing the benefits and limitations of the operating microscope, the progression of OCT technology, and OCT applications in clinical/perioperative retinal imaging. Next, we review intraoperative OCT (iOCT) applications using handheld probes during surgical pauses, two-dimensional (2D) microscope-integrated OCT (MIOCT) of live surgery, and volumetric MIOCT of live surgery. The iOCT discussion focuses on technological advancements, applications during human retinal surgery, translational difficulties and limitations, and future directions. PMID:27409495

  4. Visual detection of particulates in x-ray images of processed meat products

    NASA Astrophysics Data System (ADS)

    Schatzki, Thomas F.; Young, Richard; Haff, Ron P.; Eye, J.; Wright, G.

    1996-08-01

    A study was conducted to test the efficacy of detecting particulate contaminants in processed meat samples by visual observation of line-scanned x-ray images. Six hundred field- collected processed-product samples were scanned at 230 cm2/s using 0.5 X 0.5-mm resolution and 50 kV, 13 mA excitation. The x-ray images were image corrected, digitally stored, and inspected off-line, using interactive image enhancement. Forty percent of the samples were spiked with added contaminants to establish the visual recognition of contaminants as a function of sample thickness (1 to 10 cm), texture of the x-ray image (smooth/textured), spike composition (wood/bone/glass), size (0.1 to 0.4 cm), and shape (splinter/round). The results were analyzed using a maximum likelihood logistic regression method. In packages less than 6 cm thick, 0.2-cm-thick bone chips were easily recognized, 0.1-cm glass splinters were recognized with some difficulty, while 0.4-cm-thick wood was generally missed. Operational feasibility in a time-constrained setting was confirmed. One half percent of the samples arriving from the field contained bone slivers > 1 cm long, 1/2% contained metallic material, while 4% contained particulates exceeding 0.3 cm in size. All of the latter appeared to be bone fragments.

  5. Thermal probe design for Europa sample acquisition

    NASA Astrophysics Data System (ADS)

    Horne, Mera F.

    2018-01-01

    The planned lander missions to the surface of Europa will access samples from the subsurface of the ice in a search for signs of life. A small thermal drill (probe) is proposed to meet the sample requirement of the Science Definition Team's (SDT) report for the Europa mission. The probe is 2 cm in diameter and 16 cm in length and is designed to access the subsurface to 10 cm deep and to collect five ice samples of 7 cm3 each, approximately. The energy required to penetrate the top 10 cm of ice in a vacuum is 26 Wh, approximately, and to melt 7 cm3 of ice is 1.2 Wh, approximately. The requirement stated in the SDT report of collecting samples from five different sites can be accommodated with repeated use of the same thermal drill. For smaller sample sizes, a smaller probe of 1.0 cm in diameter with the same length of 16 cm could be utilized that would require approximately 6.4 Wh to penetrate the top 10 cm of ice, and 0.02 Wh to collect 0.1 g of sample. The thermal drill has the advantage of simplicity of design and operations and the ability to penetrate ice over a range of densities and hardness while maintaining sample integrity.

  6. Comparison of a suspended radiation protection system versus standard lead apron for radiation exposure of a simulated interventionalist.

    PubMed

    Marichal, Daniel A; Anwar, Temoor; Kirsch, David; Clements, Jessica; Carlson, Luke; Savage, Clare; Rees, Chet R

    2011-04-01

    To evaluate the radiation protective characteristics of a system designed to enhance operator protection while eliminating weight to the body and allowing freedom of motion. Radiation doses to a mock interventionalist were measured with calibrated dosimeters in a clinical interventional suite. A standard lead apron (SLA; Pb equivalent, 0.5 mm) was compared with a suspended radiation protection system (ZeroGravity; Zgrav) that shields from the top of the head to the calves (except the right arm and left forearm) with a complex overhead motion system that eliminates weight on the operator and allows freedom of motion. Zgrav included a suspended lead apron with increased lead equivalency, greater length, proximal left arm and shoulder coverage, and a wraparound face shield of 0.5 mm Pb equivalency. A 26-cm-thick Lucite stack (ie, mock patient) created scatter during 10 controlled angiography sequences of 120 exposures each. Parameters included a field of view of 40 cm, table height of 94 cm, 124 cm from the tube to image intensifier, 50 cm from the image center to operator, 66 kVp, and 466-470 mA. Under identical conditions, average doses (SLA vs Zgrav) were 264 versus 3.4 (ratio, 78) to left axilla (P < .001), 456 versus 10.2 (ratio, 45) to left eye (P < .001), 379.4 versus 6.6 (ratio, 57) to right eye (P < .005), and 18.8 versus 1.2 (ratio, 16) to gonad (P < .001). Relative to a conventional lead apron, the Zgrav system provided a 16-78-fold decrease in radiation exposure for a mock interventionalist in a simulated clinical setting. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  7. Radiation hardness of Efratom M-100 rubidium frequency standard

    NASA Technical Reports Server (NTRS)

    English, T. C.; Vorwerk, H.; Rudie, N. J.

    1983-01-01

    The effects of nuclear radiation on rubidium gas cell frequency standards and components are presented, including the results of recent tests where a continuously operating rubidium frequency standard (Effratom, Model M-100) was subjected to simultaneous neutron/gamma radiation. At the highest neutron fluence 7.5 10 to the 12th power n/sq cm and total dose 11 krad(Si) tested, the unit operated satisfactorily; the total frequency change over the 2 1/2 hour test period due to all causes, including repeated retraction from and insertion into the reactor, was less than 1 x 10 to the -10th power. The effects of combined neutron/gamma radiation on rubidium frequency standard physics package components were also studied, and the results are presented.

  8. [Remote Slit Lamp Microscope Consultation System Based on Web].

    PubMed

    Chen, Junfa; Zhuo, Yong; Liu, Zuguo; Chen, Yanping

    2015-11-01

    To realize the remote operation of the slit lamp microscope for department of ophthalmology consultation, and visual display the real-time status of remote slit lamp microscope, a remote slit lamp microscope consultation system based on B/S structure is designed and implemented. Through framing the slit lamp microscope on the website system, the realtime acquisition and transmission of remote control and image data is realized. The three dimensional model of the slit lamp microscope is established and rendered on the web by using WebGL technology. The practical application results can well show the real-time interactive of the remote consultation system.

  9. Influence of interleukin 12 on p53 peptide vaccination against established Meth A sarcoma.

    PubMed Central

    Noguchi, Y; Richards, E C; Chen, Y T; Old, L J

    1995-01-01

    BALB/c murine sarcoma Meth A is known to have three missense point mutations in p53. We previously reported that a nonamer peptide containing the codon 234 mutational product (designated 234CM) elicited 234CM-specific cytotoxic T cells and that immunization with 234CM in adjuvant before tumor challenge inhibited Meth A growth. Because interleukin 12 (IL-12) has been shown to have antitumor activity against established tumors and immuno-modulatory activities, we analyzed its effect on p53 peptide immunization and Meth A growth. Multiple injections of IL-12 alone (4 times a week for 2 weeks) caused regression of established Meth A sarcoma, and this effect was dose dependent. IL-12 treatment prior to Meth A challenge had little or no antitumor activity. To evaluate the effect of IL-12 on the generation of 234CM-specific cytotoxic T lymphocytes, spleen cells from BALB/c mice immunized with 234CM in adjuvant and injected with various doses of IL-12 were sensitized with 234CM in vitro. Multiple injections of 1 ng of IL-12 induced the highest cytotoxicity against target cells pulsed with 234CM. Higher doses of IL-12 suppressed 234CM-specific cytotoxic T-cell generation. Mice immunized with 234CM in QS-21 adjuvant and treated with 1 ng of IL-12 rejected established Meth A sarcoma. Mice comparably treated with 1 ng of IL-12 but immunized with 234CW peptide (the wild-type counterpart to 234CM) in QS-21 or with QS-21 alone showed progressive tumor growth. PMID:7892250

  10. Multi-walled carbon nanotubes: sampling criteria and aerosol characterization

    PubMed Central

    Chen, Bean T.; Schwegler-Berry, Diane; McKinney, Walter; Stone, Samuel; Cumpston, Jared L.; Friend, Sherri; Porter, Dale W.; Castranova, Vincent; Frazer, David G.

    2015-01-01

    This study intends to develop protocols for sampling and characterizing multi-walled carbon nanotube (MWCNT) aerosols in workplaces or during inhalation studies. Manufactured dry powder containing MWCNT’s, combined with soot and metal catalysts, form complex morphologies and diverse shapes. The aerosols, examined in this study, were produced using an acoustical generator. Representative samples were collected from an exposure chamber using filters and a cascade impactor for microscopic and gravimetric analyses. Results from filters showed that a density of 0.008–0.10 particles per µm2 filter surface provided adequate samples for particle counting and sizing. Microscopic counting indicated that MWCNT’s, resuspended at a concentration of 10 mg/m3, contained 2.7 × 104 particles/cm3. Each particle structure contained an average of 18 nanotubes, resulting in a total of 4.9 × 105 nanotubes/cm3. In addition, fibrous particles within the aerosol had a count median length of 3.04 µm and a width of 100.3 nm, while the isometric particles had a count median diameter of 0.90 µm. A combination of impactor and microscopic measurements established that the mass median aerodynamic diameter of the mixture was 1.5 µm. It was also determined that the mean effective density of well-defined isometric particles was between 0.71 and 0.88 g/cm3, and the mean shape factor of individual nanotubes was between 1.94 and 2.71. The information obtained from this study can be used for designing animal inhalation exposure studies and adopted as guidance for sampling and characterizing MWCNT aerosols in workplaces. The measurement scheme should be relevant for any carbon nanotube aerosol. PMID:23033994

  11. Vector sensor for scanning SQUID microscopy

    NASA Astrophysics Data System (ADS)

    Dang, Vu The; Toji, Masaki; Thanh Huy, Ho; Miyajima, Shigeyuki; Shishido, Hiroaki; Hidaka, Mutsuo; Hayashi, Masahiko; Ishida, Takekazu

    2017-07-01

    We plan to build a novel 3-dimensional (3D) scanning SQUID microscope with high sensitivity and high spatial resolution. In the system, a vector sensor consists of three SQUID sensors and three pick-up coils realized on a single chip. Three pick-up coils are configured in orthogonal with each other to measure the magnetic field vector of X, Y, Z components. We fabricated some SQUID chips with one uniaxial pick-up coil or three vector pick-up coils and carried out fundamental measurements to reveal the basic characteristics. Josephson junctions (JJs) of sensors are designed to have the critical current density J c of 320 A/cm2, and the critical current I c becomes 12.5 μA for the 2.2μm × 2.2μm JJ. We carefully positioned the three pickup coils so as to keep them at the same height at the centers of all three X, Y and Z coils. This can be done by arranging them along single line parallel to a sample surface. With the aid of multilayer technology of Nb-based fabrication, we attempted to reduce an inner diameter of the pickup coils to enhance both sensitivity and spatial resolution. The method for improving a spatial resolution of a local magnetic field image is to employ an XYZ piezo-driven scanner for controlling the positions of the pick-up coils. The fundamental characteristics of our SQUID sensors confirmed the proper operation of our SQUID sensors and found a good agreement with our design parameters.

  12. 42 CFR 84.146 - Method of measuring the power and torque required to operate blowers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Method of measuring the power and torque required... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.146 Method of measuring the power and torque... drum, a (13 cm. (5 inches) in diameter is convenient). This drum is wound with about 12 m. (40 feet) of...

  13. Diffuse optical tomography using semiautomated coregistered ultrasound measurements

    NASA Astrophysics Data System (ADS)

    Mostafa, Atahar; Vavadi, Hamed; Uddin, K. M. Shihab; Zhu, Quing

    2017-12-01

    Diffuse optical tomography (DOT) has demonstrated huge potential in breast cancer diagnosis and treatment monitoring. DOT image reconstruction guided by ultrasound (US) improves the diffused light localization and lesion reconstruction accuracy. However, DOT reconstruction depends on tumor geometry provided by coregistered US. Experienced operators can manually measure these lesion parameters; however, training and measurement time are needed. The wide clinical use of this technique depends on its robustness and faster imaging reconstruction capability. This article introduces a semiautomated procedure that automatically extracts lesion information from US images and incorporates it into the optical reconstruction. An adaptive threshold-based image segmentation is used to obtain tumor boundaries. For some US images, posterior shadow can extend to the chest wall and make the detection of deeper lesion boundary difficult. This problem can be solved using a Hough transform. The proposed procedure was validated from data of 20 patients. Optical reconstruction results using the proposed procedure were compared with those reconstructed using extracted tumor information from an experienced user. Mean optical absorption obtained from manual measurement was 0.21±0.06 cm-1 for malignant and 0.12±0.06 cm-1 for benign cases, whereas for the proposed method it was 0.24±0.08 cm-1 and 0.12±0.05 cm-1, respectively.

  14. Time-resolved detection of the CF3 photofragment using chirped QCL radiation.

    PubMed

    Hancock, G; Horrocks, S J; Ritchie, G A D; Helden, J H van; Walker, R J

    2008-10-09

    This paper demonstrates how a quantum cascade laser (QCL) in its intrapulse mode can provide a simple method for probing the products of a photolysis event. The system studied is the 266 nm photodissociation of CF3I with the CF3 fragments subsequently detected using radiation at approximately 1253 cm(-1) generated by a pulsed QCL. The tuning range provided by the frequency down-chirp of the QCL operated in its intrapulse mode allows a approximately 1 cm(-1) segment of the CF3 nu3 band to be measured following each photolysis laser pulse. Identification of features within this spectral region allows the CF3 ( v = 0) number density to be calculated as a function of pump-probe delay, and consequently the processes which populate and deplete this quantum state may be examined. Rate constants for the population cascade from higher vibrational levels into the v = 0 state, k 1, and for the recombination of the CF3 radicals to form C2F6, k2, are measured. The returned values of k1 = (2.3 +/- 0.34) x 10(-12) cm(3) molecule(-1) s(-1) and k2 = (3.9 +/- 0.34) x 10(-12) cm(3) molecule(-1) s(-1) are found to be in good agreement with reported literature values.

  15. A Thomson scattering diagnostic on the Pegasus Toroidal experiment.

    PubMed

    Schlossberg, D J; Schoenbeck, N L; Dowd, A S; Fonck, R J; Moritz, J I; Thome, K E; Winz, G R

    2012-10-01

    By exploiting advances in high-energy pulsed lasers, volume phase holographic diffraction gratings, and image intensified CCD cameras, a new Thomson scattering system has been designed to operate from 532 - 592 nm on the Pegasus Toroidal Experiment. The system uses a frequency-doubled, Q-switched Nd:YAG laser operating with an energy of 2 J at 532 nm and a pulse duration of 7 ns FWHM. The beam path is < 7m, the beam diameter remains ≤ 3 mm throughout the plasma, and the beam dump and optical baffling is located in vacuum but can be removed for maintenance by closing a gate valve. A custom lens system collects scattered photons from 15 cm < R(maj) < 85 cm at ~F∕6 with 14 mm radial resolution. Initial measurements will be made at 12 spatial locations with 12 simultaneous background measurements at corresponding locations. The estimated signal at the machine-side collection optics is ~3.5 × 10(4) photons for plasma densities of 10(19) m(-3). Typical plasmas measured will range from densities of mid-10(18) to mid-10(19) m(-3) with electron temperatures from 10 to 1000 eV.

  16. Hydrodynamic and material properties experiments using pulsed power techniques

    NASA Astrophysics Data System (ADS)

    Reinovsky, R. E.; Trainor, R. J.

    2000-04-01

    Within the last five years, a new approach to the exploration of dynamic material properties and advanced hydrodynamics at extreme conditions has joined the traditional techniques of high velocity guns and explosives. This new application uses electromagnetic energy to accelerate solid density material to produce shocks in a cylindrical target. The principal tool for producing high energy density environments is the high precision, magnetically imploded, near-solid density cylindrical liner. The most attractive pulsed power system for driving such experiments is an ultrahigh current, low impedance, microsecond time scale source that is economical both to build and to operate. Two families of pulsed power systems can be applied to drive such experiments. The 25-MJ Atlas capacitor bank system currently under construction at Los Alamos is the first system of its scale specifically designed to drive high precision solid liners. Delivering 30 MA, Atlas will provide liner velocities 12-15 km/sec and kinetic energies of 1-2 MJ/cm with extensive diagnostics and excellent reproducibility. Explosive flux compressor technology provides access to currents exceeding 100 MA producing liner velocities above 25 km/sec and kinetic energies of 5-20 MJ/cm in single shot operations

  17. Electrochemical study of lithiated transition metal oxide composite for single layer fuel cell

    NASA Astrophysics Data System (ADS)

    Hu, Huiqing; Lin, Qizhao; Muhammad, Afzal; Zhu, Bin

    2015-07-01

    This study analyzed the effect of various semiconductors of transition metal oxides in modified lithiated NiO on the electrochemical performance of a single layer fuel cell (SLFC). A typical ionic conductor Ce0.8Sm0.2O2-δ (SDC) and three types of semiconductors Li0.3Ni0.6Cu0.07Sr0.03O2-δ (LNCuS), Li0.3Ni0.6Mn0.07Sr0.03O2-δ (LNMnS) and Li0.3Ni0.6Co0.07Sr0.03O2-δ (LNCoS), were the fundamental components of the SLFCs. The components were characterized by using X-ray diffraction (XRD), a scanning electron microscope (SEM), and an energy-dispersive X-ray spectrometer (EDS). The stability of the synthesized materials was evaluated using thermal gravity analysis (TGA). The ohmic resistances at 500 °C were 0.36, 0.48 and 0.58 Ω cm2 for 6SDC-4LNMnS, 6SDC-4LNCoS and 6SDC-4LNCuS, respectively. Among the three SLFCs, the single cell with 6SDC-4LNMnS achieves the highest power density (422 mW cm-2) but the lowest temperature stability, while the single cell with 6SDC-4LNCuS achieved the lowest power density (331 mW cm-2) but the highest temperature stability during the operation temperature.

  18. Mid-Infrared Study of Samples from Multiple Stones from the Sutters Mill Meteorite

    NASA Technical Reports Server (NTRS)

    Sandford, S. A.; Nuevo, M.; Flynn, G. J.; Wirick, S.

    2013-01-01

    The Sutter's Mill meteorite fell in N. California on April 22, 2012 and numerous pieces have been recovered and studied. We present Fourier transform infrared (FTIR) spectra of fragments from several stones of the meteorite. Methods and analysis: Infrared spectra of the samples were recorded with a Nicolet iN10 MX FTIR microscope in the mid-IR range (4000-675/cm; spectral resolution 4/cm). All samples were deposited on a clean glass slide, crushed with a stainless steel roller tool, and placed directly on the focal plane of the microscope. IR spectra were collected by averaging 128 scans. Results: Preliminary IR spectra of the non-fusion crust samples show mineral compositions that are dominated by phyllosilicates, carbonates, or mixtures of both [2]. The carbonates display a dominant, broad band centered at 1433/cm, with additional bands at 2515/cm, 1797/cm, 882/cm, and 715/cm). Features associated with phyllosilicates include a symmetric Si-O stretching mode band centered at 1011/cm and several O-H stretching mode bands. The O-H shows up in two forms (1) a broadband centered at 3415/cm that is probably largely due to adsorbed H2O and (2) a much weaker, narrower feature centered near 3680/cm due to structural -OH. Features observed in the 2985-2855/cm range suggest the presence of aliphatic -CH3 and -CH2- groups. The relative intensities of the bands in this range are somewhat unusual. Typically, the asymmetric aliphatic CH stretching bands are stronger than the symmetric stretching bands, but in this case the reverse is true. This unusual pattern is well matched by the aliphatic features seen in the spectrum of a terrestrial calcite (CaCO3) standard. This observation, and the fact that the strength of the carbonate and aliphatic bands seem to correlate, suggest the organics are associated with the carbonates. Conclusions: IR spectra of samples from the Sutter's Mill meteorite show absorption features associated with carbonates, phyllosilicates, and organics. Both the unusual band profile of the aliphatic C-H stretching mode bands and their correlation with the strength of the carbonate bands suggests the organics and the carbonates are associated in some manner.

  19. Great enhancement of pyroelectric properties for Ba{sub 0.65}Sr{sub 0.35}TiO{sub 3} films on Pt-Si substrates by inserting a self-buffered layer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, C. G.; Li, Y. R.; Zhu, J.

    2009-02-15

    (100)-Ba{sub 0.65}Sr{sub 0.35}TiO{sub 3} (BST) films were deposited on Pt/Ti/SiO{sub 2}/Si substrates using a low-temperature self-buffered layer. X-ray diffraction and atomic force microscope investigations show that the microstructure of BST films strongly depends on surface morphology of annealed self-buffered layer. The mechanism of nucleus formation and the growth initiation of BST films on self-buffered layers were proposed. It was found that the pyroelectric properties of BST films can be greatly enhanced. The pyroelectric coefficient and material merit figure of (100)-BST films are 1.16x10{sup 4} {mu}C m{sup -2} K{sup -1} and 2.18x10{sup -4} Pa{sup -1/2}, respectively. The detectivity of 9.4x10{sup 7}more » cm Hz{sup 1/2} W{sup -1} was obtained in the (100)-BST film capacitors thermally isolated by 500 nm SiO{sub 2} films.« less

  20. Endonasal laser-assisted microscopic dacryocystorhinostomy: surgical technique and follow-up results.

    PubMed

    Farzampour, Shahrokh; Fayazzadeh, Ehsan; Mikaniki, Ebrahim

    2010-01-01

    Endonasal dacryocystorhinostomy is known as an increasingly attractive and effective approach for the surgical treatment of nasal duct obstruction with minimal complications and best cosmetic consequences. In a relatively large-scale case-series study over a 5-year period, we describe the surgical technique and 12-month follow-up results of microscopic laser dacryocystorhinostomy with particular regard to the effect of various pre-/postoperational factors (ie, patients' sex, age, symptoms chronicity, previous interventions, duration of silicone intubation) on the surgical outcome. A total of 162 cases in 151 patients with chronic epiphora, mucocele, or recurrent episodes of dacryocystitis were included in the study. Endonasal laser dacryocystorhinostomy was performed using a surgical microscope with transcanalicular lacrimal sac illumination. The laser types used were potassium-titanyl-phosphate and neodymium:yttrium-aluminum-garnet for ablation of nasal mucosa and application to bone, respectively. Patients were evaluated 6 months and 1 year later. Data were analyzed by chi(2) tests. There were no major complications during or after the operations. Complete cure occurred in 89.5% (after 6 months) and 74.2% (after 1 year) of the cases. Anatomical patency was shown by lacrimal system irrigation with fluorescein in 81.5% of the cases after the 12-month follow-up. It was found that patients younger than 55 years, with symptoms lasting less than 1 year, and without history of nasal problems, had significantly higher surgical success rates (P < .05). Moreover, rates of failure were significantly lower in cases whose canaliculi were intubated for 5 to 6 months (P < .05). Endonasal microscopic laser dacryocystorhinostomy is a safe and minimally invasive procedure with reasonable results. It has many advantages over external or other conventional approaches. Successful results could be further enhanced by more wisely selecting the patients and by silicone extubation after 6 months. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  1. ScanImage: flexible software for operating laser scanning microscopes.

    PubMed

    Pologruto, Thomas A; Sabatini, Bernardo L; Svoboda, Karel

    2003-05-17

    Laser scanning microscopy is a powerful tool for analyzing the structure and function of biological specimens. Although numerous commercial laser scanning microscopes exist, some of the more interesting and challenging applications demand custom design. A major impediment to custom design is the difficulty of building custom data acquisition hardware and writing the complex software required to run the laser scanning microscope. We describe a simple, software-based approach to operating a laser scanning microscope without the need for custom data acquisition hardware. Data acquisition and control of laser scanning are achieved through standard data acquisition boards. The entire burden of signal integration and image processing is placed on the CPU of the computer. We quantitate the effectiveness of our data acquisition and signal conditioning algorithm under a variety of conditions. We implement our approach in an open source software package (ScanImage) and describe its functionality. We present ScanImage, software to run a flexible laser scanning microscope that allows easy custom design.

  2. Evaluation of a recently developed noncontact specular microscope in comparison with conventional pachymetry devices.

    PubMed

    Módis, László; Szalai, Eszter; Németh, Gábor; Berta, András

    2010-01-01

    The study was conducted to assess the central corneal thickness (CCT) of the healthy cornea with a recently developed noncontact specular microscope (EM-3000; Tomey) and compare the results with those measured with a contact specular microscope and an ultrasound pachymeter. Agreement between measurements taken by 2 investigators was also studied. The right eyes of 41 healthy individuals who had negative history of contact lens wear, ophthalmic disease, or ocular surgery were examined. The CCT was determined sequentially with a noncontact specular microscope, a contact specular microscope (EM-1000; Tomey), and an ultrasound pachymeter (AL-2000; Tomey). Each evaluation with the specular microscopes was performed by 2 independent operators. A significant difference was detected in pachymetry measurements among the 3 instruments (p=0.01; analysis of variance). The mean CCT values were lower measured with the ultrasound pachymeter (537+/-30 microm) than the contact endothelial microscope (543+/-37 microm, p=0.17, Student t-test) and the noncontact microscope (549+/-33 microm, p<0.0001) (operator 1). There was no statistically significant difference in CCT measurements between the 2 endothelial microscopes (p=0.19). We found significant correlations (p<0.0001) in thickness measurements between each pair of instruments (r=0.91, noncontact microscopy and ultrasound pachymetry; r=0.74, noncontact and contact microscopy; r=0.72, contact microscopy and ultrasound pachymetry; Spearman rank correlation). The strong correlations among the 3 pachymetry devices suggest that the tested instruments provide reliable measurements; however, they cannot be used interchangeably.

  3. CUSUM analysis of learning curves for the head-mounted microscope in phonomicrosurgery.

    PubMed

    Chen, Ting; Vamos, Andrew C; Dailey, Seth H; Jiang, Jack J

    2016-10-01

    To observe the learning curve of the head-mounted microscope in a phonomicrosurgery simulator using cumulative summation (CUSUM) analysis, which incorporates a magnetic phonomicrosurgery instrument tracking system (MPTS). Retrospective case series. Eight subjects (6 medical students and 2 surgeons inexperienced in phonomicrosurgery) operated on phonomicrosurgical simulation cutting tasks while using the head-mounted microscope for 400 minutes total. Two 20-minute sessions occurred each day for 10 total days, with operation quality (Qs ) and completion time (T) being recorded after each session. Cumulative summation analysis of Qs and T was performed by using subjects' performance data from trials completed using a traditional standing microscope as success criteria. The motion parameters from the head-mounted microscope were significantly better than the standing microscope (P < 0.01), but T was longer than that from the standing microscope (P < 0.01). No subject successfully adapted to the head-mounted microscope, as assessed by CUSUM analysis. Cumulative summation analysis can objectively monitor the learning process associated with a phonomicrosurgical simulator system, ultimately providing a tool to assess learning status. Also, motion parameters determined by our MPTS showed that, although the head-mounted microscope provides better motion control, worse Qs and longer T resulted. This decrease in Qs is likely a result of the relatively unstable visual environment that it provides. Overall, the inexperienced surgeons participating in this study failed to adapt to the head-mounted microscope in our simulated phonomicrosurgery environment. 4 Laryngoscope, 126:2295-2300, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Compact, single-tube scanning tunneling microscope with thermoelectric cooling.

    PubMed

    Jobbins, Matthew M; Agostino, Christopher J; Michel, Jolai D; Gans, Ashley R; Kandel, S Alex

    2013-10-01

    We have designed and built a scanning tunneling microscope with a compact inertial-approach mechanism that fits inside the piezoelectric scanner tube. Rigid construction allows the microscope to be operated without the use of external vibration isolators or acoustic enclosures. Thermoelectric cooling and a water-ice bath are used to increase temperature stability when scanning under ambient conditions.

  5. Detection of carbon-fluorine bonds in organofluorine compounds by Raman spectroscopy using a copper-vapor laser

    NASA Astrophysics Data System (ADS)

    Sharts, Clay M.; Gorelik, Vladimir S.; Agoltsov, A. M.; Zlobina, Ludmila I.; Sharts, Olga N.

    1999-02-01

    The Raman spectra of fluoro-organic compounds show specific emission bands for carbon-fluorine bonds in the range 500- 800 wave numbers (cm-1)). With very limited exceptions, biological materials do not contain carbon- fluorine bonds. Fluoro-organic compounds introduced into biological samples can be detected by a Raman emission signal. Normal mode C-F bond bands are observed: (1) at 710- 785 cm -1 for trifluoromethyl groups; (2) at 530-610 cm -1 for aromatic organofluorine bonds; (3) a range centered at 690 cm -1 for difluoromethylene groups. Specific examples of normal mode C-F bond emissions for organofluorine compounds containing trifluoromethyl groups are: 1-bromoperfluorooctane, 726 cm -1; perfluorodecanoic acid, 730 cm -1; triperfluoropropylamine, 750 cm -1; 1,3,5-tris- (trifluoromethyl)-benzene, 730 cm -1; Fluoxetine (Prozac) commercial powdered pill at 782 cm -1. Compounds containing aromatic C-F bonds are: hexafluorobenzene, 569 cm MIN1; pentafluoropyridine, 589 cm -1. Difluoromethylene groups: perfluorodecalin, 692 cm-1; perfluorocyclohexane, 691 cm -1. Raman spectra were observed with a standard single monochromator. The 510.8 nm light source was a copper-vapor laser operated at 3-10 watts with 10-12 nanosecond pulses at 10 kHz repetition rate. Detection was made with a time-gated photomultiplier tube. Resonance Raman spectra were also observed at 255.4 nm, using a frequency doubling crystal. Observed spectra were free of fluorescence with very sharp strong C-F lines.

  6. Gain and energy storage in holmium YLF

    NASA Technical Reports Server (NTRS)

    Storm, Mark E.; Deyst, John P.

    1991-01-01

    It is demonstrated that Q-switched holmium lasers are capable of high-gain and high-energy operation at 300 K. Small-signal gain coefficients of 0.50 and 0.12/cm have been measured in YLF and YAG, respectively. Small-signal gains of 0.50/cm are comparable to those achievable in Nd:YAG and are not typical of low-gain materials. This large gain in the Ho:YLF material is made possible by operating the amplifier in the ground state depletion mode. The amplifier performance data and associated analysis presented demonstrate that efficient energy storage is possible with very high excited state ion densities of the Ho 5I7 upper laser level. This is an important result since upconversion can limit the 5I7 population. Although upconversion was still present in this experiment, it was possible to achieve efficient energy storage, demonstrating that the problem is manageable even at high excitation densities in YLF.

  7. A case of granuloma of the ascending colon due to penetration of Trichuris trichiura.

    PubMed

    Kojima, Y; Sakuma, H; Izumi, R; Nakagawara, G; Miyazaki, I; Yoshimura, H

    1981-01-01

    A 33 year-old woman was admitted with chief complaint of abdominal pain and high fever. A barium-enema showed serration and a tumor was seen in the proximal ascending colon. At laparotomy, a localized tumor about 5 cm in diameter was located in the proximal portion of the ascending colon. The operation was made according to the ileoceal resection. On the macroscopic examination of the resected specimen, a small hole penetrating into the subserosa of the ascending colon was noticed and a tumor measuring approximately 3 x 1.2 x 1 cm was located under the hole. A female worm, Trichuris trichiura, was found to be harbored in the adjacent site of the lesion. Histopathologic examination revealed granulomatous tissue reaction due to penetrating of Trichuris trichiura. The patient is in good health now 20 months after operation.

  8. Engineering model 8-cm thruster subsystem

    NASA Technical Reports Server (NTRS)

    Herron, B. G.; Hyman, J.; Hopper, D. J.; Williamson, W. S.; Dulgeroff, C. R.; Collett, C. R.

    1978-01-01

    An Engineering Model (EM) 8 cm Ion Thruster Propulsion Subsystem was developed for operation at a thrust level 5 mN (1.1 mlb) at a specific impulse 1 sub sp = 2667 sec with a total system input power P sub in = 165 W. The system dry mass is 15 kg with a mercury-propellant-reservoir capacity of 8.75 kg permitting uninterrupted operation for about 12,500 hr. The subsystem can be started from a dormant condition in a time less than or equal to 15 min. The thruster has a design lifetime of 20,000 hr with 10,000 startup cycles. A gimbal unit is included to provide a thrust vector deflection capability of + or - 10 degrees in any direction from the zero position. The EM subsystem development program included thruster optimization, power-supply circuit optimization and flight packaging, subsystem integration, and subsystem acceptance testing including a cyclic test of the total propulsion package.

  9. Combination of hand-held probe and microscopy for fluorescence guided surgery in the brain tumor marginal zone.

    PubMed

    Richter, Johan C O; Haj-Hosseini, Neda; Hallbeck, Martin; Wårdell, Karin

    2017-06-01

    Visualization of the tumor is crucial for differentiating malignant tissue from healthy brain during surgery, especially in the tumor marginal zone. The aim of the study was to introduce a fluorescence spectroscopy-based hand-held probe (HHF-probe) for tumor identification in combination with the fluorescence guided resection surgical microscope (FGR-microscope), and evaluate them in terms of diagnostic performance and practical aspects of fluorescence detection. Eighteen operations were performed on 16 patients with suspected high-grade glioma. The HHF-probe and the FGR-microscope were used for detection of protoporphyrin (PpIX) fluorescence induced by 5-aminolevulinic acid (5-ALA) and evaluated against histopathological analysis and visual grading done through the FGR-microscope by the surgeon. A ratio of PpIX fluorescence intensity to the autofluorescence intensity (fluorescence ratio) was used to quantify the spectra detected by the probe. Fluorescence ratio medians (range 0 - 40) measured by the probe were related to the intensity of the fluorescence in the FGR-microscope, categorized as "none" (0.3, n=131), "weak" (1.6, n=34) and "strong" (5.4, n=28). Of 131 "none" points in the FGR-microscope, 88 (67%) exhibited fluorescence with the HHF-probe. For the tumor marginal zone, the area under the receiver operator characteristics (ROC) curve was 0.49 for the FGR-microscope and 0.65 for the HHF-probe. The probe was integrated in the established routine of tumor resection using the FGR-microscope. The HHF-probe was superior to the FGR-microscope in sensitivity; it detected tumor remnants after debulking under the FGR-microscope. The combination of the HHF-probe and the FGR-microscope was beneficial especially in the tumor marginal zone. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Foam generation and sample composition optimization for the FOAM-C experiment of the ISS

    NASA Astrophysics Data System (ADS)

    Carpy, R.; Picker, G.; Amann, B.; Ranebo, H.; Vincent-Bonnieu, S.; Minster, O.; Winter, J.; Dettmann, J.; Castiglione, L.; Höhler, R.; Langevin, D.

    2011-12-01

    End of 2009 and early 2010 a sealed cell, for foam generation and observation, has been designed and manufactured at Astrium Friedrichshafen facilities. With the use of this cell, different sample compositions of "wet foams" have been optimized for mixtures of chemicals such as water, dodecanol, pluronic, aethoxisclerol, glycerol, CTAB, SDS, as well as glass beads. This development is performed in the frame of the breadboarding development activities of the Experiment Container FOAM-C for operation in the ISS Fluid Science Laboratory (ISS). The sample cell supports multiple observation methods such as: Diffusing-Wave and Diffuse Transmission Spectrometry, Time Resolved Correlation Spectroscopy [1] and microscope observation, all of these methods are applied in the cell with a relatively small experiment volume <3cm3. These units, will be on orbit replaceable sets, that will allow multiple sample compositions processing (in the range of >40).

  11. Normal incidence reflectance of ion beam deposited SiC films in the EUV

    NASA Technical Reports Server (NTRS)

    Keski-Kuha, Ritva A. M.; Osantowski, John F.; Herzig, Howard; Gum, Jeffrey S.; Toft, Albert R.

    1988-01-01

    Results are presented from an experimental investigation of the normal-incidence reflectance at 58.4, 92.0, and 121.6 nm wavelength of 30- and 80-nm-thick SiC films produced by ion-beam deposition on unheated 5 x 5-cm microscope slides. The films were deposited in the 2-m evaporator described by Bradford et al. (1969) with chamber base pressure 1 microtorr, operating pressure 40 microtorr, and a 50-62-mA 750-eV Ar ion beam; the reflectance measurements were obtained in the reflector-monochromator system described by Osantowski (1974). Reflectances of over 30 percent were found at 92 and 121.6 nm, almost equal to those of polished CVD films of SiC and degrading only slightly after aging for 4 months. It is suggested that ion-beam deposition may be the best low-temperature technique for coating EUV optics for space astronomy.

  12. Growth and field emission properties of globe-like diamond microcrystalline-aggregate

    NASA Astrophysics Data System (ADS)

    Gao, Jin-hai; Zhang, Lan; Zhao, Limin; Hao, Haoshan

    2009-02-01

    The globe-like diamond microcrystalline-aggregates were fabricated by microwave plasma chemical vapor deposition (MPCVD) method. The ceramic with a Ti mental layer was used as substrate. The fabricated diamond was evaluated by Raman scattering spectroscopy, X-ray diffraction spectrum (XRD), and scanning electron microscope (SEM). The field emission properties were tested by using a diode structure in a vacuum. A phosphor-coated indium tin oxide (ITO) anode was used for observing and characterizing the field emission. It was found that the globe-like diamond microcrystalline-aggregates exhibited good electron emission properties. The turn-on field was only 0.55 V/μm, and emission current density as high as 11 mA/cm 2 was obtained under an applied field of 2.9 V/μm for the first operation. The growth mechanism and field emission properties of the globe-like diamond microcrystalline-aggregates are discussed relating to microstructure and electrical conductivity.

  13. Advances in Dust Detection and Removal for Tokamaks

    NASA Astrophysics Data System (ADS)

    Campos, A.; Skinner, C. H.; Roquemore, A. L.; Leisure, J. O. V.; Wagner, S.

    2008-11-01

    Dust diagnostics and removal techniques are vital for the safe operation of next step fusion devices such as ITER. An electrostatic dust detector[1] developed in the laboratory is being applied to NSTX. In the tokamak environment, large particles or fibres can fall on the grid potentially causing a permanent short. We report on the development of a gas puff system that uses helium to clear such particles from the detector. Experiments with varying nozzle designs, backing pressures, puff durations, and exit flow orientations have obtained an optimal configuration that effectively removes particles from a 25 cm^2 area. Dust removal from next step tokamaks will be required to meet regulatory dust limits. A tripolar grid of fine interdigitated traces has been designed that generates an electrostatic travelling wave for conveying dust particles to a ``drain.'' First trials have shown particle motion in optical microscope images. [1] C. H. Skinner et al., J. Nucl. Mater., 376 (2008) 29.

  14. Mixed anion materials and compounds for novel proton conducting membranes

    DOEpatents

    Poling, Steven Andrew; Nelson, Carly R.; Martin, Steve W.

    2006-09-05

    The present invention provides new amorphous or partially crystalline mixed anion chalcogenide compounds for use in proton exchange membranes which are able to operate over a wide variety of temperature ranges, including in the intermediate temperature range of about 100 .degree. C. to 300.degree. C., and new uses for crystalline mixed anion chalcogenide compounds in such proton exchange membranes. In one embodiment, the proton conductivity of the compounds is between about 10.sup.-8 S/cm and 10.sup.-1 S/cm within a temperature range of between about -60 and 300.degree. C. and a relative humidity of less than about 12%..

  15. Long lifetime hollow cathodes for 30-cm mercury ion thrusters

    NASA Technical Reports Server (NTRS)

    Mirtich, M. J.; Kerslake, W. R.

    1976-01-01

    An experimental investigation of hollow cathodes for 30-cm Hg bombardment thrusters was carried out. Both main and neutralizer cathode configurations were tested with both rolled foil inserts coated with low work function material and impregnated porous tungsten inserts. Temperature measurements of an impregnated insert at various positions in the cathode were made. These, along with the cathode thermal profile are presented. A theory for rolled foil and impregnated insert operation and lifetime in hollow cathodes is developed. Several endurance tests, as long as 18,000 hours at emission currents of up to 12 amps were attained with no degradation in performance.

  16. Coarse particle speciation at selected locations in the rural continental United States

    NASA Astrophysics Data System (ADS)

    Malm, William C.; Pitchford, Marc L.; McDade, Charles; Ashbaugh, Lowell L.

    A few short-term special studies at National Parks have shown that coarse mass (CM) (2.5- 10μm) may not be just crustal minerals but may consist of a substantial amount ( ≈40-50%) of carbonaceous material and inorganic salts such as calcium nitrate and sodium nitrate. To more fully investigate the composition of coarse particles, a program of coarse particle sampling and speciation analysis at nine of the Interagency Monitoring of Protected Visual Environments (IMPROVE) sites was initiated 19 March 2003 and operated through the year 2004. Only the data for 2004 are reported here. Sites were selected to be representative of the continental United States and were operated according to IMPROVE protocol analytical procedures. Crustal minerals (soil) are the single largest contributor to CM at all but one monitoring location. The average fractional contributions range from a high of 76% at Grand Canyon National Park to a low of 34% at Mount Rainier National Park. The second largest contributor to CM is organic mass, which on an average annual fractional basis is highest at Mount Rainier at 59%. At Great Smoky Mountains National Park, organic mass contributes 40% on average, while at four sites organic mass concentrations contribute between 20% and 30% of the CM. Nitrates are on average the third largest contributor to CM concentrations. The highest fractional contributions of nitrates to CM are at Brigantine National Wildlife Refuge, Great Smoky Mountains, and San Gorgonio wilderness area at 10-12%. Sulfates contribute less than about 5% at all sites.

  17. Microscopic simulation model calibration and validation handbook.

    DOT National Transportation Integrated Search

    2006-01-01

    Microscopic traffic simulation models are widely used in the transportation engineering field. Because of their cost-effectiveness, risk-free nature, and high-speed benefits, areas of use include transportation system design, traffic operations, and ...

  18. Spectral characteristics of iron-bearing phyllosilicates: Comparison to Orgueil (CI1), Murchison and Murray (CM2)

    USGS Publications Warehouse

    Calvin, W.M.; King, T.V.V.

    1997-01-01

    Phyllosilicate alteration minerals are commonly found in low petrologic types of carbonaceous chondrites. Previous spectral studies have examined Mg-bearing phyllosilicates with limited success in matching the spectral properties of CM and CI chondrites. Transmission electron microscope and other analytical techniques suggest that Fe-bearing clays are more abundant in CI and CM chondrites than magnesian varieties. Here, we present the results of an examination of the reflectance spectra of Fe-phyllosilicates, including serpentines and berthierines, of which the latter were formerly known as septechlorites. We have measured the diffuse reflectance spectra of powdered samples from 0.3 to 25 ??m. We find that these minerals provide a better spectral match to many of the features seen in CI and CM chondrites, and simple linear combinations of the spectra of both Fe- and Mg-phyllosilicates closely approximate the spectra of CM and CI chondrites.

  19. Estimation of safe exposure time from an ophthalmic operating microscope with regard to ultraviolet radiation and blue-light hazards to the eye

    NASA Astrophysics Data System (ADS)

    Michael, Ralph; Wegener, Alfred

    2004-08-01

    Hazards from the optical radiation of an operating microscope that cause damage at the corneal, lenticular, and retinal levels were investigated; we considered, in particular, ultraviolet radiation (UVR) and blue light. The spectral irradiance from a Zeiss operation microscope OPMI VISU 200 was measured in the corneal plane between 300 and 1100 nm. Effective irradiance and radiance were calculated with relative spectral effectiveness data from the American Conference for Governmental and Industrial Hygienists. Safe exposure time to avoid UVR injury to the lens and cornea was found to be 2 h without a filter, 4 h with a UVR filter, 200 h with a yellow filter, and 400 h with a filter combination. Safe exposure time to avoid retinal photochemical injury was found to be 3 min without a filter and with a UVR filter, 10 min with a yellow filter, and 49 min with a filter combination. The effective radiance limit for retinal thermal injury was not exceeded. The hazard due to the UVR component from the operating microscope is not critical, and operation time can be safely prolonged with the use of appropriate filters. The retinal photochemical hazard appears critical without appropriate filters, permitting only some minutes of safe exposure time. The calculated safe exposure times are for worst-case conditions and maximal light output and include a safety factor.

  20. Estimation of safe exposure time from an ophthalmic operating microscope with regard to ultraviolet radiation and blue-light hazards to the eye.

    PubMed

    Michael, Ralph; Wegener, Alfred

    2004-08-01

    Hazards from the optical radiation of an operating microscope that cause damage at the corneal, lenticular, and retinal levels were investigated; we considered, in particular, ultraviolet radiation (UVR) and blue light. The spectral irradiance from a Zeiss operation microscope OPMI VISU 200 was measured in the corneal plane between 300 and 1100 nm. Effective irradiance and radiance were calculated with relative spectral effectiveness data from the American Conference for Governmental and Industrial Hygienists. Safe exposure time to avoid UVR injury to the lens and cornea was found to be 2 h without a filter, 4 h with a UVR filter, 200 a yellow filter, and 400 h with a filter combination. Safe exposure time to avoid retinal photochemical injury was found to be 3 min without a filter and with a UVR filter, 10 min with a yellow filter, and 49 min with a filter combination. The effective radiance limit for retinal thermal injury was not exceeded. The hazard due to the UVR component from the operating microscope is not critical, and operation time can be safely prolonged with the use of appropriate filters. The retinal photochemical hazard appears critical without appropriate filters, permitting only some minutes of safe exposure time. The calculated safe exposure times are for worst-case conditions and maximal light output and include a safety factor.

  1. Junctionless Thin-Film Transistors Gated by an H₃PO₄-Incorporated Chitosan Proton Conductor.

    PubMed

    Liu, Huixuan; Xun, Damao

    2018-04-01

    We fabricated an H3PO4-incorporated chitosan proton conductor film that exhibited the electric double layer effect and showed a high specific capacitance of 4.42 μF/cm2. Transparent indium tin oxide thin-film transistors gated by H3PO4-incorporated chitosan films were fabricated by sputtering through a shadow mask. The operating voltage was as low as 1.2 V because of the high specific capacitance of the H3PO4-incorporated chitosan dielectrics. The junctionless transparent indium tin oxide thin film transistors exhibited good performance, including an estimated current on/off ratio and field-effect mobility of 1.2 × 106 and 6.63 cm2V-1s-1, respectively. These low-voltage thin-film electric-double-layer transistors gated by H3PO4-incorporated chitosan are promising for next generation battery-powered "see-through" portable sensors.

  2. [Pedicled superior gluteal artery perforator bilateral quadrilobed flaps for repair of large sacrococcygeal pressure sores].

    PubMed

    Hai, Henglin; Li, Huatao; Chen, Yang; Li, Qiang; Wu, Shenggang; Lili, Wang; Yan, Lei; Xiaoying, Zhou

    2013-03-01

    To investigate the effectiveness of pedicled superior gluteal artery perforator bilateral quadrilobed flaps for repairing large sacrococcygeal pressure sores. Between June 2003 and August 2011, 6 paraplegia patients with large sacrococcygeal pressure sores were repaired with the pedicled superior gluteal artery perforator bilateral quadrilobed flaps. There were 2 males and 4 females with an average age of 45.6 years (range, 37-62 years). The mean disease duration was 8.4 months (range, 3-26 months). According to National Pressure Ulcer Advisory Panel (NPUAP) standard, 6 cases rated as degree IV. The size of pressure sores ranged from 15 cm x 13 cm to 18 cm x 16 cm. The size of flaps ranged from 18 cm x 14 cm to 21 cm x 15 cm. After operation, all flaps survived successfully. The wounds healed by first intention in 5 cases; partial dehiscence of incision occurred in 1 case, which was cured after dressing change for 26 days. Six patients were followed up 6-24 months (mean, 12.5 months). The appearance and texture of the flaps were smooth and soft with good elasticity and no ulceration. Pedicled superior gluteal artery perforator bilateral quadrilobed flaps can repair large sacrococcygeal pressure sores. The appearance of flaps is smooth and has good compression-resistance effect.

  3. Performance evaluation of a slow-release packing material-embedded functional microorganisms for biofiltration.

    PubMed

    Zhu, Rencheng; Li, Shunyi; Wu, Zhenjun; Dumont, Éric

    2017-04-01

    A composite packing material (CM-5) was prepared in this study, mainly consisting of compost with functional microorganisms, calcium carbonate (CaCO 3 ), perlite, cement and plant fiber. To get stronger compressive strength, mass ratios of these components were optimized based on single factor experiments, and finally adding amounts of perlite, cement, plant fiber, CaCO 3 , compost and binder at 18%, 18%, 7%, 13%, 17% and 27%, respectively. According to the optimum proportion, CM-5 was extruded in cylindrical shape (12 mm in diameter and 20 mm in length) with a bulk density of 470 kg m -3 , a moisture retention capacity of 49% and the microbial counts of × 10 5 CFU g -1 of packing material. The cumulative release rates of total organic carbon (TOC) and total nitrogen (TN) from CM-5 were 3.1% and 6.5%, respectively, after 19 times extraction in distilled water. To evaluate the H 2 S removal capacity, CM-5 was compared with an organic (corncob) and an inorganic (ceramsite) packing material in three biofilters. The results showed that CM-5 had higher H 2 S removal capacity compared with corncob and ceramsite. CM-5 could avoid the large fluctuation of pH value and pressure drop during the operation. The maximum H 2 S removal capacity of CM-5 was 12.9 g m -3  h -1 and the removal efficiency could maintain over 95.4% when the inlet H 2 S loading rate was lower than 11.3 g m -3  h -1 without any addition of nutrients and pH buffer substances. Besides, only 2-3 days were needed for the recovery of biofiltration performance after about two weeks of idle period.

  4. An empirical spectroscopic database for acetylene in the regions of 5850-6341 cm-1 and 7000-9415 cm-1

    NASA Astrophysics Data System (ADS)

    Lyulin, O. M.; Campargue, A.

    2017-12-01

    Six studies have been recently devoted to a systematic analysis of the high-resolution near infrared absorption spectrum of acetylene recorded by Cavity Ring Down spectroscopy (CRDS) in Grenoble and by Fourier-transform spectroscopy (FTS) in Brussels and Hefei. On the basis of these works, in the present contribution, we construct an empirical database for acetylene in the 5850-9415 cm-1 region excluding the 6341-7000 cm-1 interval corresponding to the very strong ν1+ν3 manifold. Our database gathers and extends information included in our CRDS and FTS studies. In particular, the intensities of about 1700 lines measured by CRDS in the 7244-7920 cm-1 region are reported for the first time together with those of several bands of 12C13CH2 present in natural isotopic abundance in the acetylene sample. The Herman-Wallis coefficients of most of the bands are derived from a fit of the measured intensity values. A recommended line list is provided with positions calculated using empirical spectroscopic parameters of the lower and upper energy vibrational levels and intensities calculated using the derived Herman-Wallis coefficients. This approach allows completing the experimental list by adding missing lines and improving poorly determined positions and intensities. As a result the constructed line list includes a total of 11113 transitions belonging to 150 bands of 12C2H2 and 29 bands of 12C13CH2. For comparison the HITRAN database in the same region includes 869 transitions of 14 bands, all belonging to 12C2H2. Our weakest lines have an intensity on the order of 10-29 cm/molecule, about three orders of magnitude smaller than the HITRAN intensity cut off. Line profile parameters are added to the line list which is provided in HITRAN format. The comparison of the acetylene database to the HITRAN2012 line list or to results obtained using the global effective operator approach is discussed in terms of completeness and accuracy.

  5. Searches for Kaluza-Klein graviton excitations and microscopic black holes with the aid of the CMS detector at the LHC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Savina, M. V., E-mail: savina@cern.ch

    2015-06-15

    A survey of the results of the Compact Muon Solenoid (CMS) experiment that concern searches for massive Kaluza-Klein graviton excitations and microscopic black holes, quantum black holes, and string balls within models of low-energy multidimensional gravity is presented on behalf of the CMS Collaboration. The analysis in question is performed on the basis of a complete sample of data accumulated for proton-proton collisions at the c.m. energies of 7 and 8 TeV at the Large Hadron Collider (LHC) over the period spanning 2010 and 2012.

  6. Large area Czochralski silicon

    NASA Technical Reports Server (NTRS)

    Rea, S. N.; Gleim, P. S.

    1977-01-01

    The overall cost effectiveness of the Czochralski process for producing large-area silicon was determined. The feasibility of growing several 12 cm diameter crystals sequentially at 12 cm/h during a furnace run and the subsequent slicing of the ingot using a multiblade slurry saw were investigated. The goal of the wafering process was a slice thickness of 0.25 mm with minimal kerf. A slice + kerf of 0.56 mm was achieved on 12 cm crystal using both 400 grit B4C and SiC abrasive slurries. Crystal growth experiments were performed at 12 cm diameter in a commercially available puller with both 10 and 12 kg melts. Several modifications to the puller hoz zone were required to achieve stable crystal growth over the entire crystal length and to prevent crystallinity loss a few centimeters down the crystal. The maximum practical growth rate for 12 cm crystal in this puller design was 10 cm/h, with 12 to 14 cm/h being the absolute maximum range at which melt freeze occurred.

  7. The ablation threshold of Er;Cr:YSGG laser radiation in bone tissue

    NASA Astrophysics Data System (ADS)

    Benetti, Carolina; Zezell, Denise Maria

    2015-06-01

    In laser cut clinical applications, the use of energy densities lower than the ablation threshold causes increase of temperature of the irradiated tissue, which might result in an irreversible thermal damage. Hence, knowing the ablation threshold is crucial for insuring the safety of these procedures. The aim of this study was to determine the ablation threshold of the Er,Cr:YSGG laser in bone tissue. Bone pieces from jaws of New Zealand rabbits were cut as blocks of 5 mm × 8 mm and polished with sandpaper. The Er,Cr:YSGG laser used in this study had wavelength of 2780 nm, 20 Hz of frequency, and the irradiation condition was chosen so as to simulate the irradiation during a surgical procedure. The laser irradiation was performed with 12 different values of laser energy densities, between 3 J/cm2 and 42 J/cm2, during 3 seconds, resulting in the overlap of 60 pulses. This process was repeated in each sample, for all laser energy densities. After irradiation, the samples were analyzed by scanning electron microscope (SEM), and it was measured the crater diameter for each energy density. By fitting a curve that related the ablation threshold with the energy density and the corresponding diameter of ablation crater, it was possible to determine the ablation threshold. The results showed that the ablation threshold of the Er,Cr:YSGG in bone tissue was 1.95+/-0.42 J/cm2.

  8. Analytic Morse/long-range potential energy surfaces and "adiabatic-hindered-rotor" treatment for a symmetric top-linear molecule dimer: A case study of CH3F-H2

    NASA Astrophysics Data System (ADS)

    Zhang, Xiao-Long; Ma, Yong-Tao; Zhai, Yu; Li, Hui

    2018-03-01

    A first effective six-dimensional ab initio potential energy surface (PES) for CH3F-H2 which explicitly includes the intramolecular Q3 stretching normal mode of the CH3F monomer is presented. The electronic structure computations have been carried out at the explicitly correlated coupled cluster level of theory [CCSD(T)-F12a] with an augmented correlation-consistent triple zeta basis set. Five-dimensional analytical intermolecular PESs for ν3(CH3F) = 0 and 1 are then obtained by fitting the vibrationally averaged potentials to the Morse/Long-Range (MLR) potential function form. The MLR function form is applied to the nonlinear molecule-linear molecule case for the first time. These fits to 25 015 points have root-mean-square deviations of 0.74 cm-1 and 0.082 cm-1 for interaction energies less than 0.0 cm-1. Using the adiabatic hindered-rotor approximation, three-dimensional PESs for CH3F-paraH2 are generated from the 5D PESs over all possible orientations of the hydrogen monomer. The infrared and microwave spectra for CH3F-paraH2 dimer are predicted for the first time. These analytic PESs can be used for modeling the dynamical behavior in CH3F-(H2)N clusters, including the possible appearance of microscopic superfluidity.

  9. Feasibility of Pathology-Correlated Lung Imaging for Accurate Target Definition of Lung Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stroom, Joep; Blaauwgeers, Hans; Baardwijk, Angela van

    2007-09-01

    Purpose: To accurately define the gross tumor volume (GTV) and clinical target volume (GTV plus microscopic disease spread) for radiotherapy, the pretreatment imaging findings should be correlated with the histopathologic findings. In this pilot study, we investigated the feasibility of pathology-correlated imaging for lung tumors, taking into account lung deformations after surgery. Methods and Materials: High-resolution multislice computed tomography (CT) and positron emission tomography (PET) scans were obtained for 5 patients who had non-small-cell lung cancer (NSCLC) before lobectomy. At the pathologic examination, the involved lung lobes were inflated with formalin, sectioned in parallel slices, and photographed, and microscopic sectionsmore » were obtained. The GTVs were delineated for CT and autocontoured at the 42% PET level, and both were compared with the histopathologic volumes. The CT data were subsequently reformatted in the direction of the macroscopic sections, and the corresponding fiducial points in both images were compared. Hence, the lung deformations were determined to correct the distances of microscopic spread. Results: In 4 of 5 patients, the GTV{sub CT} was, on average, 4 cm{sup 3} ({approx}53%) too large. In contrast, for 1 patient (with lymphangitis carcinomatosa), the GTV{sub CT} was 16 cm{sup 3} ({approx}40%) too small. The GTV{sub PET} was too small for the same patient. Regarding deformations, the volume of the well-inflated lung lobes on pathologic examination was still, on average, only 50% of the lobe volume on CT. Consequently, the observed average maximal distance of microscopic spread (5 mm) might, in vivo, be as large as 9 mm. Conclusions: Our results have shown that pathology-correlated lung imaging is feasible and can be used to improve target definition. Ignoring deformations of the lung might result in underestimation of the microscopic spread.« less

  10. Urethroplasty for treatment of long anterior urethral stricture: buccal mucosa graft versus penile skin graft-does the stricture length matter?

    PubMed

    Hussein, Mohamed M; Almogazy, Hazem; Mamdouh, Ahmed; Farag, Fawzy; Rashed, Elnesr; Gamal, Wael; Rashed, Ahmed; Zaki, Mohamed; Salem, Esam; Ryad, Ahmed

    2016-11-01

    To investigate the surgical outcomes of dorsal onlay urethroplasty (DOU) using buccal mucosa graft (BMG) or penile skin graft (PSG) and to assess the effect of stricture length in men with anterior urethral strictures. A prospective cohort included men with anterior urethral strictures between 2008 and 2015. Patients underwent DOU using PSG or BMG. Patients had urethrography and uroflowmetry at 0, 3, 6, 12 months, and urethroscopy when needed. Student's t test, Mann-Whitney U tests, and Pearson's Chi-square test were used for analysis. Sixty-nine patients (43 ± 14 year) were included, 31 received BMG, and 38 received PSG. Mean stricture length was 8 ± 3 cm, mean operative time was 145 ± 31 min, and mean follow-up was 56 ± 10 mo. Success rate was 87 % (90 % BMG vs. 84 % PSG, p = 0.4). Mean operative time was significantly shorter in PSG group (136 ± 29 min vs. 256 ± 58 min, p = 0.0005). Complications of grade I developed in 36 % (wound infection = 10 %, postvoiding dribbling = 18.8 %). Thirty of 69 patients (43 %) had strictures ≥8 cm, and 39 (57 %) had strictures <8 cm-success rate was equal for both subgroups (87 %). Mean blood loss, mean operative time, and incidence of postvoid dribbling were significantly lower in strictures <8 cm. BMG and PSG have comparable success rates in treatment of long anterior urethral strictures. Operative time is significantly longer in BMG. Long-segment strictures are associated with longer operative time, more blood loss, and more occurrence of postvoid dribbling. However, the length of the stricture has no influence on the success rate and functional outcomes of DOU.

  11. Effect of soil properties on Hydraulic characteristics under subsurface drip irrigation

    NASA Astrophysics Data System (ADS)

    Fan, Wangtao; Li, Gang

    2018-02-01

    Subsurface drip irrigation (SDI) is a technique that has a high potential in application because of its high efficiency in water-saving. The hydraulic characteristics of SDI sub-unit pipe network can be affected by soil physical properties as the emitters are buried in soils. The related research, however, is not fully explored. The laboratory tests were carried out in the present study to determine the effects of hydraulic factors including operating pressure, initial soil water content, and bulk density on flow rate and its sensitivity to each hydraulic factor for two types of SDI emitters (PLASSIM emitter and Heping emitter). For this purpose, three soils with contrasting textures (i.e., light sand, silt loam, and light clay) were repacked with two soil bulk density (1.25 and1.40 g cm-3) with two initial soil water content (12% and 18%) in plexiglass columns with 40 cm in diameter and 40 cm in height. Drip emitters were buried at depth of 20 cm to measure the flow rates under seven operating pressures (60, 100, 150, 200, 250, 300, and 370 kPa). We found that the operating pressure was the dominating factor of flow rate of the SDI emitter, and flow rate increased with the increase of operating pressure. The initial soil water content and bulk density also affected the flow rate, and their effects were the most notable in the light sand soil. The sensitivity of flow rate to each hydraulic factor was dependent on soil texture, and followed a descending order of light sand>silt loam>light clay for both types of emitters. Further, the sensitivity of flow rate to each hydraulic factor decreased with the increase of operating pressure, initial soil water content, and bulk density. This study may be used to guide the soil specific-design of SDI emitters for optimal water use and management.

  12. Coherent anti-Stokes Raman scattering spectroscope/microscope based on a widely tunable laser source

    NASA Astrophysics Data System (ADS)

    Dementjev, A.; Gulbinas, V.; Serbenta, A.; Kaucikas, M.; Niaura, G.

    2010-03-01

    We present a coherent anti-Stokes Raman scattering (CARS) microscope based on a robust and simple laser source. A picosecond laser operating in a cavity dumping regime at the 1 MHz repetition rate was used to pump a traveling wave optical parametric generator, which serves as a two-color excitation light source for the CARS microscope. We demonstrate the ability of the presented CARS microscope to measure CARS spectra and images by using several detection schemes.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tournadre, Grégoire de, E-mail: gregoire.de-tournadre@univ-reims.fr; Reisdorffer, Frédéric; Simonetti, Olivier

    A scanning surface potential measurement technique suited for thin-film devices operating under high voltages is reported. A commercial atomic force microscope has been customized to enable a feedback-controlled and secure surface potential measurement based on phase-shift detection under ambient conditions. Measurements of the local potential profile along the channel of bottom-gate organic thin-film transistors (TFTs) are shown to be useful to disentangle the contributions from the channel and contacts to the device performance. Intrinsic contact current-voltage characteristics have been measured on bottom-gate, top-contact (staggered) TFTs based on the small-molecule semiconductor dinaphtho[2,3-b:2′,3-f]thieno[3,2-b]thiophene (DNTT) and on bottom-gate, bottom-contact (coplanar) TFTs based onmore » the semiconducting polymer polytriarylamine (PTAA). Injection has been found to be linear in the staggered DNTT TFTs and nonlinear in the coplanar PTAA TFTs. In both types of TFT, the injection efficiency has been found to improve with increasing gate bias in the accumulation regime. Contact resistances as low as 130 Ω cm have been measured in the DNTT TFTs. A method that eliminates the influence of bias-stress-induced threshold-voltage shifts when measuring the local charge-carrier mobility in the channel is also introduced, and intrinsic channel mobilities of 1.5 cm{sup 2} V{sup −1} s{sup −1} and 1.1 × 10{sup −3} cm{sup 2} V{sup −1} s{sup −1} have been determined for DNTT and PTAA. In both semiconductors, the mobility has been found to be constant with respect to the gate bias. Despite its simplicity, the Kelvin probe force microscopy method reported here provides robust and accurate surface potential measurements on thin-film devices under operation and thus paves the way towards more extensive studies of particular interest in emerging fields of solid-state electronics.« less

  14. [Formulation of guidelines for microscopic endodontics suitable for the situation of China].

    PubMed

    Ling, J Q

    2016-08-01

    In order to promote the use of dental operating microscope in endodontics, Society of Cariology and Endodontology of Chinese Stomatological Association formulated these guidelines, after extensive consultation with related authorities and careful reference to the available published materials and literatures. It is hoped that these guidelines will be useful for dental practitioners embarking on microscopic endodontics.

  15. Evaluation of Argonne 9-cm and 10-cm Annular Centrifugal Contactors for SHINE Solution Processing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wardle, Kent E.; Pereira, Candido; Vandegrift, George

    2015-02-01

    Work is in progress to evaluate the SHINE Medical Technologies process for producing Mo-99 for medical use from the fission of dissolved low-enriched uranium (LEU). This report addresses the use of Argonne annular centrifugal contactors for periodic treatment of the process solution. In a letter report from FY 2013, Pereira and Vandegrift compared the throughput and physical footprint for the two contactor options available from CINC Industries: the V-02 and V-05, which have rotor diameters of 5 cm and 12.7 cm, respectively. They suggested that an intermediately sized “Goldilocks” contactor might provide a better balance between throughput and footprint tomore » meet the processing needs for the uranium extraction (UREX) processing of the SHINE solution to remove undesired fission products. Included with the submission of this letter report are the assembly drawings for two Argonne-design contactors that are in this intermediate range—9-cm and 10-cm rotors, respectively. The 9-cm contactor (drawing number CE-D6973A, stamped February 15, 1978) was designed as a single-stage unit and built and tested in the late 1970s along with other size units, both smaller and larger. In subsequent years, a significant effort to developed annular centrifugal contactors was undertaken to support work at Hanford implementing the transuranic extraction (TRUEX) process. These contactors had a 10-cm rotor diameter and were fully designed as multistage units with four stages per assembly (drawing number CMT-E1104, stamped March 14, 1990). From a technology readiness perspective, these 10-cm units are much farther ahead in the design progression and, therefore, would require significantly less re-working to make them ready for UREX deployment. Additionally, the overall maximum throughput of ~12 L/min is similar to that of the 9-cm unit (10 L/min), and the former could be efficiently operated over much of the same range of throughput. As a result, only the 10-cm units are considered here, though drawings are provided for the 9-cm unit for reference.« less

  16. Spatial confinement effects on spectroscopic and morphological studies of nanosecond laser-ablated Zirconium

    NASA Astrophysics Data System (ADS)

    Hayat, Asma; Bashir, Shazia; Rafique, Muhammad Shahid; Ahmad, Riaz; Akram, Mahreen; Mahmood, Khaliq; Zaheer, Ali

    2017-12-01

    Spatial confinement effects on plasma parameters and surface morphology of laser ablated Zr (Zirconium) are studied by introducing a metallic blocker. Nd:YAG laser at various fluencies ranging from 8 J cm-2 to 32 J cm-2 was employed as an irradiation source. All measurements were performed in the presence of Ar under different pressures. Confinement effects offered by metallic blocker are investigated by placing the blocker at different distances of 6 mm, 8 mm and 10 mm from the target surface. It is revealed from LIBS analysis that both plasma parameters i.e. excitation temperature and electron number density increase with increasing laser fluence due to enhancement in energy deposition. It is also observed that spatial confinement offered by metallic blocker is responsible for the enhancement of both electron temperature and electron number density of Zr plasma. This is true for all laser fluences and pressures of Ar. Maximum values of electron temperature and electron number density without blocker are 12,600 K and 14 × 1017 cm-3 respectively whereas, these values are enhanced to 15,000 K and 21 × 1017 cm-3 in the presence of blocker. The physical mechanisms responsible for the enhancement of Zr plasma parameters are plasma compression, confinement and pronounced collisional excitations due to reflection of shock waves. Scanning Electron Microscope (SEM) analysis was performed to explore the surface morphology of laser ablated Zr. It reveals the formation of cones, cavities and ripples. These features become more distinct and well defined in the presence of blocker due to plasma confinement. The optimum combination of blocker distance, fluence and Ar pressure can identify the suitable conditions for defining the role of plasma parameters for surface structuring.

  17. Schottky barrier diode based on β-Ga2O3 (100) single crystal substrate and its temperature-dependent electrical characteristics

    NASA Astrophysics Data System (ADS)

    He, Qiming; Mu, Wenxiang; Dong, Hang; Long, Shibing; Jia, Zhitai; Lv, Hangbing; Liu, Qi; Tang, Minghua; Tao, Xutang; Liu, Ming

    2017-02-01

    The Pt/β-Ga2O3 Schottky barrier diode and its temperature-dependent current-voltage characteristics were investigated for power device application. The edge-defined film-fed growth (EFG) technique was utilized to grow the (100)-oriented β-Ga2O3 single crystal substrate that shows good crystal quality characterized by X-ray diffraction and high resolution transmission electron microscope. Ohmic and Schottky electrodes were fabricated by depositing Ti and Pt metals on the two surfaces, respectively. Through the current-voltage (I-V) measurement under different temperature and the thermionic emission modeling, the fabricated Pt/β-Ga2O3 Schottky diode was found to show good performances at room temperature, including rectification ratio of 1010, ideality factor (n) of 1.1, Schottky barrier height (ΦB) of 1.39 eV, threshold voltage (Vbi) of 1.07 V, ON-resistance (RON) of 12.5 mΩ.cm2, forward current density at 2 V (J@2V) of 56 A/cm2, and saturation current density (J0) of 2 × 10-16 A/cm2. The effective donor concentration Nd - Na was calculated to be about 2.3 × 1014 cm3. Good temperature dependent performance was also found in the device. The Schottky barrier height was estimated to be about 1.3 eV-1.39 eV at temperatures ranging from room temperature to 150 °C. With increasing temperature, parameters such as RON and J@2V become better, proving that the diode can work well at high temperature. The EFG grown β-Ga2O3 single crystal is a promising material to be used in the power devices.

  18. Paper plant effluent revisited-southern Lake Champlain, Vermont and New York

    USGS Publications Warehouse

    Haupt, R.S.; Folger, D.W.

    1993-01-01

    We used geologic and geochemical techniques to document the change with time of the distribution and concentration of contaminated bottom sediments in southern Lake Champlain near an International Paper Company plant. Our work, initiated in 1972, was expanded on behalf of Vermont citizens in a class-action suit against the International Paper Company. To update our 1972-1973 results, we collected nine cores in 1988 upstream and downstream from the paper plant effluent diffuser. Water content, volatile solids, organic carbon, and three ratios, Al/Si, Cl/Si, and S/Si, in addition to megascopic and microscopic observations, were evaluated to identify and trace the distribution of effluent and to measure the thickness of sediment affected by or containing components of effluent. Analyses were carried out on samples from the cores as well as from effluent collected directly from the plant's waste treatment facility. In 1973, two years after the plant opened, we cored near the diffuser; sediment contaminated with effluent was 4.5 cm thick. In 1988, in the same area, sediment contaminated with effluent was 17 cm thick. In 15 years, water content increased from 72 to 85 percent, volatile solids from 7 to 20 percent, and organic carbon from 2 to 12 percent. Cl/Si and S/Si were high only near the diffuser and were zero elsewhere. In the area of the diffuser, contaminated sediment appears to be accumulating at a rate of about 1 cm/yr. At a control location 22 km upstream (south) from the plant, the top, poorly consoli-dated layer was only 1 cm or less thick both in 1973 and in 1988. The class-action suit was settled in favor of the plaintiffs for $5 million. ?? 1993 Springer-Verlag.

  19. Scanning electron microscope/energy dispersive x ray analysis of impact residues on LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Bernhard, Ronald P.; Durin, Christian; Zolensky, Michael E.

    1992-01-01

    To better understand the nature of particulates in low-Earth orbit (LEO), and their effects on spacecraft hardware, we are analyzing residues found in impacts on the Long Duration Exposure Facility (LDEF) tray clamps. LDEF experiment trays were held in place by 6 to 8 chromic-anodized aluminum (6061-T6) clamps that were fastened to the spacecraft frame using three stainless steel hex bolts. Each clamp exposed an area of approximately 58 sq cm (4.8 cm x 12.7 cm x .45 cm, minus the bolt coverage). Some 337 out of 774 LDEF tray clamps were archived at JSC and are available through the Meteoroid & Debris Special Investigation Group (M&D SIG). Optical scanning of clamps, starting with Bay/Row A01 and working toward H25, is being conducted at JSC to locate and document impacts as small as 40 microns. These impacts are then inspected by Scanning Electron Microscopy/Energy Dispersive X-ray Analysis (SEM/EDXA) to select those features which contain appreciable impact residue material. Based upon the composition of projectile remnants, and using criteria developed at JSC, we have made a preliminary discrimination between micrometeoroid and space debris residue-containing impact features. Presently, 13 impacts containing significant amounts of unmelted and semi-melted micrometeoritic residues were forwarded to Centre National d'Etudes Spatiales (CNES) in France. At the CNES facilities, the upgraded impacts were analyzed using a JEOL T330A SEM equipped with a NORAN Instruments, Voyager X-ray Analyzer. All residues were quantitatively characterized by composition (including oxygen and carbon) to help understand interplanetary dust as possibly being derived from comets and asteroids.

  20. Ag induced electromagnetic interference shielding of Ag-graphite/PVDF flexible nanocomposites thinfilms

    NASA Astrophysics Data System (ADS)

    Kumaran, R.; Alagar, M.; Dinesh Kumar, S.; Subramanian, V.; Dinakaran, K.

    2015-09-01

    We report Ag nanoparticle induced Electromagnetic Interference (EMI) shielding in a flexible composite films of Ag nanoparticles incorporated graphite/poly-vinylidene difluoride (PVDF). PVDF nanocomposite thin-films were synthesized by intercalating Ag in Graphite (GIC) followed by dispersing GIC in PVDF. The X-ray diffraction analysis and the high-resolution transmission electron microscope clearly dictate the microstructure of silver nanoparticles in graphite intercalated composite of PVDF matrix. The conductivity values of nanocomposites are increased upto 2.5 times when compared to neat PVDF having a value of 2.70 S/cm at 1 MHz. The presence of Ag broadly enhanced the dielectric constant and lowers the dielectric loss of PVDF matrix proportional to Ag content. The EMI shielding effectiveness of the composites is 29.1 dB at 12.4 GHz for the sample having 5 wt. % Ag and 10 wt. % graphite in PVDF.

  1. Fabrication of hydrophobic structures on coronary stent surface based on direct three-beam laser interference lithography

    NASA Astrophysics Data System (ADS)

    Gao, Long-yue; Zhou, Wei-qi; Wang, Yuan-bo; Wang, Si-qi; Bai, Chong; Li, Shi-ming; Liu, Bin; Wang, Jun-nan; Cui, Cheng-kun; Li, Yong-liang

    2016-05-01

    To solve the problems with coronary stent implantation, coronary artery stent surface was directly modified by three-beam laser interference lithography through imitating the water-repellent surface of lotus leaf, and uniform micro-nano structures with the controllable period were fabricated. The morphological properties and contact angle (CA) of the microstructure were measured by scanning electron microscope (SEM) and CA system. The water repellency of stent was also evaluated by the contact and then separation between the water drop and the stent. The results show that the close-packed concave structure with the period of about 12 μm can be fabricated on the stent surface with special parameters (incident angle of 3°, laser energy density of 2.2 J·cm-2 and exposure time of 80 s) by using the three-beam laser at 1 064 nm, and the structure has good water repellency with CA of 120°.

  2. Effect of high current density to defect generation of blue LED and its characterization with transmission electron microscope

    NASA Astrophysics Data System (ADS)

    Gunawan, R.; Sugiarti, E.; Isnaeni; Purawiardi, R. I.; Widodo, H.; Muslimin, A. N.; Yuliasari; Ronaldus, C. E.; Prastomo, N.; Hastuty, S.

    2018-03-01

    The optical, electrical and structural characteristics of InGaN-based blue light-emitting diodes (LEDs) were investigated to identify the degradation of LED before and after current injection. The sample was injected by high current of 200 A/cm2 for 5 and 20 minutes. It was observed that injection of current shifts light intensity and wavelength characteristics that indicated defect generation. Transmission Electron Microscopy (TEM) characterization was carried out in order to clarify the structure degradation caused by defect in active layer which consisted of 14 quantum well with thickness of about 5 nm and confined with barrier layer with thickness of about 12 nm. TEM results showed pre-existing defect in LED before injection with high current. Furthermore, discontinue and edge defect was found in dark spot region of LED after injection with high current.

  3. Solute-solvent interactions and dynamics probed by THz light

    NASA Astrophysics Data System (ADS)

    Schwaab, Gerhard; Böhm, Fabian; Ma, Chun-Yu; Havenith, Martina

    The THz range (1-12 THz, 30-400 cm-1) is especially suited to probe changes in the solvent dynamics induced by solutes of different character (hydrophobic, hydrophilic, charged, neutral). In recent years we have investigated a large variety of such solutes and found characteristic spectral fingerprints for ions, but also for uncharged solutes, such as alcohols. We will present a status report on our current understanding of the observed spectral changes and how they relate to physico-chemical parameters like hydration shell size or the lifetime of an excited intermolecular oscillation. In addition, we will show, that in some cases the spectral changes are closely related to the partition function yielding access to a microscopic understanding of macroscopic thermodynamic functions. The authors gratefully acknowledge financial support from the Cluster of Excellence RESOLV (Ruhr-Universität, EXC1069) funded by the Deutsche Forschungsgemeinschaft.

  4. Friction and Wear Behavior of Selected Dental Ceramics

    NASA Astrophysics Data System (ADS)

    Park, Jongee; Pekkan, Gurel; Ozturk, Abdullah

    The purpose of this study was to determine the friction coefficients and wear rates of six commercially available dental ceramics including IPS Empress 2 (E2), Cergo Pressable Ceramic (CPC), Cercon Ceram (CCS) and Super porcelain EX-3 (SPE). Bovine enamel (BE) was also tested as a reference material for comparison purposes. Samples of the dental ceramics were prepared according to the instructions described by the manufacturers in disk-shape with nominal dimensions of 12 mm × 2 mm. The wear tests were performed by means of a pin-on-disk type tribometer. The friction coefficients and specific wear rates of the materials were determined at a load of 10 N and rotating speed of 0.25 cm/s without lubrication. Surface morphology of the wear tracks was examined using a scanning electron microscope. Statistical analyses were made using one-way ANOVA and Turkey's HSD (P < 0.05).

  5. [New clinical aspects of cardiac myxomas: a clinical and pathological reappraisal].

    PubMed

    Bordalo, Alvaro D B; Alves, Irina; Nobre, Angelo L; Silva, Fernanda; Lemos, Alberto; Serpa, Carlos; Fernandes, Afonso; Cravino, João

    2012-09-01

    Easy access to echocardiography and its extensive and repeated use (as is the case in Portugal) now facilitates the early diagnosis of cardiac myxoma (CM). To re-evaluate the clinical and pathological profile of CM under current diagnostic conditions. We performed a retrospective study of 40 patients consecutively referred for surgery (between January 2003 and January 2010) with a histologically-confirmed diagnosis of CM - 26 female (F) and 14 male (M), with a mean age of 64±12 years (range 12-81; 53% over 65, 43% over 70); 39 patients were operated (one was not operable due to major neurological deficit). Clinical characteristics, surgical protocols, follow-up records of survivors (range 1-76 months, with serial echocardiograms), and histological data were reviewed. The apparent incidence was 2.6 cases/million/year; the overall F/M ratio was 1.9:1 (1.3:1 in those aged over 65, similar to the general population). The CM was located in the left atrium (LA) in 92.5%, with insertion in the fossa ovalis of the interatrial septum (IAS) in 53% (only 57% of LA myxomas), and outside the IAS in 30%. The mean size was 4.6 x 3.7cm. Asymptomatic tumors occurred in 48% of the total population (sessile and/or atypically inserted in 74%; 63% of large size, over 3 x 3cm), 61% were in patients referred in the last 25 months of the study; 23% of patients showed constitutional symptoms (all with very large CMs - mean 6.7 x 5.1cm), 35% had hemodynamic/obstructive symptoms, and 15% presented with embolic events. There was evidence of CM-related mitral valve (MV) disease in 20% of patients, resulting in moderate to severe mitral regurgitation requiring associated MV surgery in 13%. Significant comorbidities were present in 69%. Surgical procedures included simple excision in 74%; septoplasty/atrioplasty associated with extensive resection of the insertion site in 26%; and combined surgery (CM excision plus other procedures) in 28%. There were significant postoperative complications in 38%. In-hospital mortality was 10%; postoperative mortality was 7.7%. Mean follow-up was 30 months (100% of survivors, 44% for >2 years); late mortality was 5.6% and no CM recurrences were observed. (1) CM has a higher incidence than described in the literature and mainly affects patients aged over 65; the reported predominance of female patients disappears after the age of 65. (2) Most CM cases are now asymptomatic at presentation as a result of earlier diagnosis. (3) CM is the cause of MV disease requiring surgical correction in more than 10% of cases, and is associated with significant postoperative mortality, mainly due to the presence of comorbidities. Copyright © 2011 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  6. Spectrum of the Wilson Dirac operator at finite lattice spacings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akemann, G.; Damgaard, P. H.; Splittorff, K.

    2011-04-15

    We consider the effect of discretization errors on the microscopic spectrum of the Wilson Dirac operator using both chiral perturbation theory and chiral random matrix theory. A graded chiral Lagrangian is used to evaluate the microscopic spectral density of the Hermitian Wilson Dirac operator as well as the distribution of the chirality over the real eigenvalues of the Wilson Dirac operator. It is shown that a chiral random matrix theory for the Wilson Dirac operator reproduces the leading zero-momentum terms of Wilson chiral perturbation theory. All results are obtained for a fixed index of the Wilson Dirac operator. The low-energymore » constants of Wilson chiral perturbation theory are shown to be constrained by the Hermiticity properties of the Wilson Dirac operator.« less

  7. Mesh versus suture repair of umbilical hernia in adults: a randomised, double-blind, controlled, multicentre trial.

    PubMed

    Kaufmann, Ruth; Halm, Jens A; Eker, Hasan H; Klitsie, Pieter J; Nieuwenhuizen, Jeroen; van Geldere, Dick; Simons, Maarten P; van der Harst, Erwin; van 't Riet, Martijne; van der Holt, Bronno; Kleinrensink, Gert Jan; Jeekel, Johannes; Lange, Johan F

    2018-03-03

    Both mesh and suture repair are used for the treatment of umbilical hernias, but for smaller umbilical hernias (diameter 1-4 cm) there is little evidence whether mesh repair would be beneficial. In this study we aimed to investigate whether use of a mesh was better in reducing recurrence compared with suture repair for smaller umbilical hernias. We did a randomised, double-blind, controlled multicentre trial in 12 hospitals (nine in the Netherlands, two in Germany, and one in Italy). Eligible participants were adults aged at least 18 years with a primary umbilical hernia of diameter 1-4 cm, and were randomly assigned (1:1) intraoperatively to either suture repair or mesh repair. In the first 3 years of the inclusion period, blocked randomisation (of non-specified size) was achieved by an envelope randomisation system; after this time computer-generated randomisation was introduced. Patients, investigators, and analysts were masked to the allocated treatment, and participants were stratified by hernia size (1-2 cm and >2-4 cm). At study initiation, all surgeons were invited to training sessions to ensure they used the same standardised techniques for suture repair or mesh repair. Patients underwent physical examinations at 2 weeks, and 3, 12, and 24-30 months after the operation. The primary outcome was the rate of recurrences of the umbilical hernia after 24 months assessed in the modified intention-to-treat population by physical examination and, in case of any doubt, abdominal ultrasound. This trial is registered with ClinicalTrials.gov, number NCT00789230. Between June 21, 2006, and April 16, 2014, we randomly assigned 300 patients, 150 to mesh repair and 150 to suture repair. The median follow-up was 25·1 months (IQR 15·5-33·4). After a maximum follow-up of 30 months, there were fewer recurrences in the mesh group than in the suture group (six [4%] in 146 patients vs 17 [12%] in 138 patients; 2-year actuarial estimates of recurrence 3·6% [95% CI 1·4-9·4] vs 11·4% (6·8-18·9); p=0·01, hazard ratio 0·31, 95% CI 0·12-0·80, corresponding to a number needed to treat of 12·8). The most common postoperative complications were seroma (one [<1%] in the suture group vs five [3%] in the mesh group), haematoma (two [1%] vs three [2%]), and wound infection (one [<1%] vs three [2%]). There were no anaesthetic complications or postoperative deaths. This is the first study showing high level evidence for mesh repair in patients with small hernias of diameter 1-4 cm. Hence we suggest mesh repair should be used for operations on all patients with an umbilical hernia of this size. Department of Surgery, Erasmus University Medical Center, Rotterdam, Netherlands. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Thermophilic co-digestion of cattle manure and food waste supplemented with crude glycerin in induced bed reactor (IBR).

    PubMed

    Castrillón, L; Marañón, E; Fernández-Nava, Y; Ormaechea, P; Quiroga, G

    2013-05-01

    The aim of the present research work was to boost biogas production from cattle manure (CM) by adding food waste (FW) and crude glycerin (Gly) from the biodiesel industry as co-substrates. For this purpose, different quantities of FW and Gly were added to CM and co-digested in an induced bed reactor (IBR) at 55 °C. Sonication pre-treatment was implemented in the CM+Gly mixture, applying 550 kJ/kg TS to enhance the biodegradability of these co-substrates. The best results were obtained with mixtures of 87/10/3 (CM/FW/Gly) (w/w) operating at an organic loading rate of 7 g COD/L day, obtaining 92% COD removal, a specific methane yield of 640 L CH4/kg VS and a methane production rate of 2.6L CH4/L day. These results doubled those obtained in the co-digestion of CM and FW without the addition of Gly (330 L CH4/kg VS and 1.2L CH4/L day). Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Effects of cadmium stress on alternative oxidase and photosystem II in three wheat cultivars.

    PubMed

    Duan, Yong-Ping; Yuan, Shu; Tu, Shi-Hua; Feng, Wen-Qiang; Xu, Fei; Zhang, Zhong-Wei; Chen, Yang-Er; Wang, Xiao; Shang, Jing; Lin, Hong-Hui

    2010-01-01

    The effects of Cd stress (200 micromol/L, 8 days) on respiration and photosynthesis of three wheat cultivars were investigated: Chuanyu 12 (CY12), Chuanmai 42 (CM42), and Chuanmai 47 (CM47). Fifteen-day-old seedlings were exposed to 200 micromol/L CdCl2 for 4 days and 8 days, respectively. The results indicated that Cd was accumulated largely in roots, but little in leaves of all three cultivars. CY12 accumulated the highest level of Cd in roots and showed the weakest resistance. On the contrary, the other two cultivars, CM42 and CM47, adapted better to Cd stress, and their thiobarbituric acid-reactive substances (TBARS) contents were lower than in CY12, but the chlorophyll contents and water contents were higher than in CY12. Additionally, Cd stress prompted the alternative oxidase (AOX) activity and upregulated the cyanide-resistant respiration in CM42 and CM47 after 8 days; no such induction was observed for CY12. The CO2 assimilation rate, leaf stomatal conductance and chlorophyll fluorescence were inhibited by Cd stress in all cultivars, but more severe in the CY12 cultivar. Western blots indicated that the content of the photosystem II proteins LHCII and D1 decreased in CY12, but did not change in CM42 and CM47. While the content of the mitochondrial AOX protein increased markedly in CM42 and CM47, it did not in CY12. These results suggested that AOX and LHCII could be regarded as indicators of plant's resistance to heavy metals.

  10. Recent conclusions regarding the reconstructive microsurgery of peripheral nerves.

    PubMed

    Dumitrescu-Ionescu, Doina

    2008-01-01

    The introducing of reconstructive microsurgery has meant not only the addition of microsurgical microscopes and instruments, but a change, a progress towards a new concept, the concept of the microsurgical reconstruction of tissues. The microscope and the instruments themselves are only a means of utilizing this new concept to good effect since the mere use of the microscope and of the instruments according to the old concept of tissue reconstruction cannot be considered to be reconstructive microsurgery. From December 1979 through to December 2005, more than 3000 patients with peripheral nerve lesions were operated on by the same microsurgeon, the author Doina Ionescu-Dumitrescu. The conclusions are based on the following: A huge amount of work involved in carrying out microsurgical reconstructions of over 7500 peripheral nerves in over 3000 patients, 1800 of which were nerve transplants for defects of peripheral nerves of the extremities, for posttraumatic brachial plexus paralyses (91), for replantations and/or revascularizations following partial or complete amputations of the extremities (24 out of which 23 successful) or for free transfers of functional composite tissues (53). For a more accurate picture of such an effort one should consider the operation time that these types of reconstruction involve: between 3 and 12 hours for each patient under general anaesthesia and for both the anaesthetist and the microsurgeon. Experimental microsurgery on rabbit ears The results of the histopathological examination of 500 postoperative neuromas of peripheral nerves repaired traditionally. The Moberg test. Pre, intra and postoperative monthly observations of the patients until their full recovery according to the criteria set by the International Reconstructive Microsurgery Society (postoperative intervals of 6-12-24 months). Taking pictures and recording pre, intra and postoperative stages. The patients' professional, social and familial reintegration. The patients' state of mind; level of cooperation. Comparing results with those of classic and palliative repairs. Comparing the data resulting from this experience with the information provided by the specialist literature of the world. Completing the internationally defined reconstructive procedures with the personal ones, to produce a new concept.

  11. [Nutrition management in obese patients with type 2 diabetes mellitus after laparoscopic sleeve gastrectomy].

    PubMed

    Tang, Weihong; Chen, Yuhua; Pan, Meizhen; Chen, Lihua; Zhang, Lele; Wang, Tingfeng; Zhang, Xiong; Zhang, Peng; Zheng, Chengzhu; Yu, Bo

    2017-04-25

    To explore the value of nutrition management in obese patients with type 2 diabetes mellitus(T2DM) after laparoscopic sleeve gastrectomy(LSG). Clinical data of 22 obese T2DM patients undergoing LSG from March 2013 to July 2015 in Fudan University Pudong Medical Center were collected. All the patients strictly followed the specialized instruction by nutritionists: diabetic and low calorie diet 3347.2 to 5020.8 kJ (800 to 1200 kcal) per day before the operation; low calorie liquid diet 2510.4 kJ(600 kcal) per day before operation for promoting gastric emptying; fasting diet before postoperative ventilation; clear liquid diet 1673.6 to 2510.4 kJ (400 to 600 kcal) per day after postoperative ventilation (liquid intake >2000 ml); low fat liquid diet 2928.8 to 3765.6 kJ (700 to 900 kcal) per day (protein 60 g per day at least, 2000 ml liquid) 2 weeks after the operation; semi-liquid diet 1 month after operation and gradually normal diet. All the 22 patients were followed up at 1 week, 1, 3, 6 months after operation on time. Changes of body weight, waist circumference, hip circumference, body mass index(BMI), blood glucose indexes induding fasting blood glucose(FBG), 2-hour postparandial blood glucose(PBG), fasting C-peptide, 2-hour postprandial C-peptide, fasting serum inculin(FINS), 2-hour postprandial inculin(INS), HbAlc, blood pressure and blood lipid indexes were observed and analyzed before and 1 week, 1, 3, 6 months after operation. The average age of 22 patients (10 men and 12 women) was 38.6 years (18 to 66 years). The duration of diabetes varied from 1 month to 15 years. Comorbidity included 12 patients of high blood pressure, 14 of fatty liver, 1 of coronary heart disease, 1 of gout, 1 of chronic thyroiditis and 1 of menstrual disorder. LSG was performed successfully in all the patients and no severe complications and transference to laparotomy occurred. As compared to pre-operation, at 6 months after operation, the average body weight decreased from (103.9±20.2) kg to (80.9±12.6) kg (t=6.294, P=0.000), waist circumference from (118.6±13.8) cm to (96.4±8.0) cm (t=6.331, P=0.000), hip circumference from (116.9±12.6) cm to (104.0±7.7) cm (t=3.854, P=0.000), BMI from (36.2±5.9) kg/m 2 to (27.9±3.5) kg/m 2 (t=5.630, P=0.000), showing a decreasing trend over time. There was no underweight patient after 6 months follow-up. As compared to pre-operation, at 6 months after operation, the average FBG reduced from (7.4±1.4) mmol/L to (6.0±0.9) mmol/L (t=3.172, P=0.003), 2 h PBG from (14.1±4.9) mmol/L to (7.5±2.2) mmol/L (t=7.026, P=0.000), FINS from (160.0±71.9) mIU/L to (43.8±20.8) mIU/L (t=7.259, P=0.000), 2-hour postprandial INS from (437.6±261.4) mIU/L to (140.5±104.6) mIU/L (t=5.858, P=0.000), fasting C-peptide from (1.1±0.6) μg/L to (0.7±0.3) μg/L (t=3.560, P=0.000), 2-hour postprandial C-peptide from (2.5±0.9) μg/L to (1.5±0.7) μg/L (t=3.865, P=0.000), HbAlc from (8.0±1.6)% to (5.9±0.6)% (t=5.953, P=0.000), showing a decreasing trend over time except FBG, 2h postprandial C-peptide and HbAlc(all P<0.05). FBG and 2-hour PBG of 16 patients returned to normal 3 months after the operation. Blood pressure and trigly ceride decreased obviously 6 months after operation compared to pre-operation with significant difference(P<0.05). At 6 months after operation, blood pressure of 8 comorbidity patients with high blood pressure became normal (8/12, 66.7%) and of 4 patients improved(4/12, 33.3%); B ultrasound examination revealed normal in 11 comorbidity patients with fatty liver(11/14,78.6%) and improvement in 3 patients (3/14,15.4%). Blood uric acid of the gout patient and the menstruation of the menstrual disorder patient returned to normal 3 months and 1 month after the operation respectively. As for obese patients with T2DM undergoing LSG, reasonable nutrition management is helpful to decrease body weight, and to obtain an ideal improvement of blood glucose and blood lipid levels.

  12. [Reconstruction of chronic Achilles tendon rupture with flexor hallucis longus tendon harvested using a minimally invasive technique].

    PubMed

    Miao, Xudong; Wu, Yongping; Tao, Huimin; Yang, Disheng

    2011-07-01

    To evaluate the effectiveness of flexor hallucis longus tendon harvested using a minimally invasive technique in reconstruction of chronic Achilles tendon rupture. Between July 2006 and December 2009, 22 patients (22 feet) with chronic Achilles tendon rupture were treated, including 16 males and 6 females with a median age of 48 years (range, 28-65 years). The disease duration was 27-1,025 days (median, 51 days). Twenty-one patients had hooflike movement's history and 1 patient had no obvious inducement. The result of Thompson test was positive in 22 cases. The score was 53.04 +/- 6.75 according to American Orthopedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. MRI indicated that the gap of the chronic Achilles tendon rupture was 4.2-8.0 cm. A 3 cm-long incision was made vertically in the plantar aspect of the midfoot and a 1 cm-long transverse incision was made in a plantar flexor crease at the base of the great toe to harvest flexor hallucis longus tendon. The flexor hallucis longus tendon was 10.5-13.5 cm longer from tuber calcanei to the end of the Achilles tendon, and then the tendon was fixed to the tuber calcanei using interface screws or anchor nail after they were woven to form reflexed 3-bundle and sutured. Wound healed by first intention in all patients and no early complication occurred. Twenty-two patients were followed up 12-42 months (mean, 16.7 months). At 12 months after operation, The AOFAS ankle and hindfoot score was 92.98 +/- 5.72, showing significant difference when compared with that before operation (t= -40.903, P=0.000). The results were excellent in 18 cases, good in 2 cases, and fair in 2 cases with an excellent and good rate of 90.9%. No sural nerve injury, posterior tibial nerve injury, plantar painful scar, medial plantar nerve injury, and lateral plantar nerve injury occurred. Chronic Achilles tendon rupture reconstruction with flexor hallucis longus tendon harvested using a minimally invasive technique offers a desirable outcome in operative recovery, tendon fixation, and complications.

  13. Inert gas ion source program

    NASA Technical Reports Server (NTRS)

    Ramsey, W. D.

    1978-01-01

    THe original 12 cm hexagonal magneto-electrostatic containment discharge chamber has been optimized for argon and xenon operation. Argon mass utilization efficiencies of 65 to 77 percent were achieved at keeper-plus-main discharge energy consumptions of 200 to 458 eV/ion, respectively. Xenon performance of 84 to 96 percent mass utilization was realized at 203 to 350 eV/ion. The optimization process and test results are discussed.

  14. Prospective comparative study of miniperc and standard PNL for treatment of 1 to 2 cm size renal stone.

    PubMed

    Mishra, Shashikant; Sharma, Rajan; Garg, Chandrapraksh; Kurien, Abraham; Sabnis, Ravindra; Desai, Mahesh

    2011-09-01

    • To evaluate the results of miniperc vis-à-vis standard PNL in the treatment of stones of 1-2 cm in size. Miniperc may represent a reasonable procedure in patients with nonbulky urolithiasis offering a similar outcome as standard percutaneous nephrolithotomy (PNL) with advantage of reduced morbidity. • 55 procedures including 27 miniperc and 28 standard PNL were performed for renal stones 1-2 cm in size. Pediatric patient, active urinary tract infection, renal malformation, uncorrected coagulopathy and morbid obesity patients were excluded from the study. • The parameters studied were demography, operative time, postoperative analgesic requirement, hemoglobin drop, complications and stone clearance. • Mean tract size was 18.2 ± 2 F (15-20) and 26.8 ± 2 F (24-30), P value <0.0001 in the miniperc and standard PNL, respectively. Holmium LASER and pneumatic lithotripter were the main energy sources used in miniperc and standard PNL, respectively. • Miniperc operative time was longer than that of standard PNL (45.2 ± 12.6 vs 31 ± 16.6 min, P= 0.0008 respectively). • Conversely, there was an advantage of miniperc over standard PNL in terms of a significantly reduced hemoglobin drop (0.8 ± 0.9 vs 1.3 ± 0.4 gram%, P= 0.01), analgesic requirement (55.4 ± 50 vs 70.2 ± 52 mg tramadol, P= 0.29) and hospital stay (3.2 ± 0.8 vs 4.8 ± 0.6 days, P ≤ 0.001), respectively. • Intra- operative conversion of the procedure into a tubeless PNL was significantly more in the miniperc group (P ≤ 0.001). The miniperc and standard PNL group had clearance rates of 96% and 100%, respectively at 1 month follow up. • This study demonstrated significant advantages of the miniperc procedure in terms of reduced bleeding leading to a tubeless procedure and reduced hospital stay. • The stone free rates and the complications were similar in either group. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  15. TU-F-CAMPUS-T-04: An Evaluation of Out-Of-Field Doses for Electron Beams From Modern Varian and Elekta Linear Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cardenas, C; Nitsch, P; Kudchadker, R

    2015-06-15

    Purpose: Accurately determining out-of-field doses when using electron beam radiotherapy is of importance when treating pregnant patients or patients with implanted electronic devices. Scattered doses outside of the applicator field in electron beams have not been broadly investigated, especially since manufacturers have taken different approaches in applicator designs. Methods: In this study, doses outside of the applicator field were measured for electron beams produced by a 10×10 applicator on two Varian 21iXs operating at 6, 9, 12, 16, and 20 MeV, a Varian TrueBeam operating at 6, 9, 12, 16, and 20 MeV, and an Elekta Versa HD operating atmore » 6, 9, 12 and 15 MeV. Peripheral dose profiles and percent depth doses were measured in a Wellhofer water phantom at 100 cm SSD with a Farmer ion chamber. Doses were compared to peripheral photon doses from AAPM’s Task Group #36 report. Results: Doses were highest for the highest electron energies. Doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. Substantial dose differences were observed between different accelerators; the Elekta accelerator had much higher doses than any Varian unit examined. Surprisingly, doses were often similar to, and could be much higher than, doses from photon therapy. Doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. Conclusion: The results of this study indicate that proper shielding may be very important when utilizing electron beams, particularly on a Versa HD, while treating pregnant patients or those with implanted electronic devices. Applying a water equivalent bolus of Emax(MeV)/4 thickness (cm) on the patient would reduce fetal dose drastically for all clinical energies and is a practical solution to manage the potentially high peripheral doses seen from modern electron beams. Funding from NIH Grant number: #CA180803.« less

  16. [Anatomy study on micro transverse flap pedicled with superfical palmar branch of radial artery from palmar wrist].

    PubMed

    Zhao, Min; Tian, Dehu; Shao, Xinzhong; Li, Dacun; Li, Jianfeng; Liu, Jingda; Zhao, Liang; Li, Hailei; Wang, Xiaolei; Zhang, Wentong; Wu, Jinying; Yuan, Zuoxiong

    2013-07-01

    To study the anatomical basis of micro transverse flap pedicled with the superfical palmar branch of radial artery from the palmar wrist for using this free flap to repair soft tissue defect of the finger. Thirty-eight fresh upper limb specimens (22 males and 16 females; aged 26-72 years with an average of 36 years; at left and right sides in 19 limbs respectively) were dissected and observed under operating microscope. Two specimens were made into casting mould of artery with bones, and 2 specimens were injected with red emulsion in radial artery. Thirty-four specimens were injected with 1% gentian violet solution in the superfical palmar branch of the radial artery. A transverse oval flap in the palmar wrist was designed, the axis of the flap was the distal palmar crease. The origin, distribution, and anastomosis of the superfical palmar branch of the radial artery were observed. The superficial palmar branch of the radial artery was constantly existed, it usually arises from the main trunk of the radial artery, 1.09-3.60 cm to proximal styloid process of radius. There were about 2-5 branches between the origin and the tubercle of scaphoid bone. The origin diameter was 1.00-3.00 mm, and the distal diameter at the styloid process of radius was 1.00-2.90 mm. The venous return of flap passed through 2 routes, and the innervations of the flap mainly from the palmar cutaneous branch of the median nerve. The area of the flap was 4 cm x 2 cm-6 cm x 2 cm. The origin and courses of the superficial palmar branch of the radial artery is constant, and its diameter is similar to that of the digital artery. A transverse oval flap pedicled with the superfical palmar branch of radial artery in the palmar wrist can be designed to repair defects of the finger.

  17. Low-intensity pulsed ultrasound treatment improved the rate of autograft peripheral nerve regeneration in rat

    PubMed Central

    Jiang, Wenli; Wang, Yuexiang; Tang, Jie; Peng, Jiang; Wang, Yu; Guo, Quanyi; Guo, Zhiyuan; Li, Pan; Xiao, Bo; Zhang, Jinxing

    2016-01-01

    Low intensity pulsed ultrasound (LIPUS) has been widely used in clinic for the treatment of repairing pseudarthrosis, bone fractures and of healing in various soft tissues. Some reports indicated that LIPUS accelerated peripheral nerve regeneration including Schwann cells (SCs) and injured nerves. But little is known about its appropriate intensities on autograft nerves. This study was to investigate which intensity of LIPUS improved the regeneration of gold standard postsurgical nerves in experimental rat model. Sprague-Dawley rats were made into 10 mm right side sciatic nerve reversed autologous nerve transplantation and randomly treated with 250 mW/cm2, 500 mW/cm2 or 750 mW/cm2 LIPUS for 2–12 weeks after operation. Functional and pathological results showed that LIPUS of 250 mW/cm2 significantly induced faster rate of axonal regeneration. This suggested that autograft nerve regeneration was improved. PMID:27102358

  18. A power device material of corundum-structured α-Ga2O3 fabricated by MIST EPITAXY® technique

    NASA Astrophysics Data System (ADS)

    Kaneko, Kentaro; Fujita, Shizuo; Hitora, Toshimi

    2018-02-01

    Corundum-structured oxides have been attracting much attention as next-generation power device materials. A corundum-structured α-Ga2O3 successfully demonstrated power device operations of Schottky barrier diodes (SBDs) with the lowest on-resistance of 0.1 mΩ cm2. The SBDs as a mounting device of TO220 also showed low switching-loss properties with a capacitance of 130 pF. Moreover, the thermal resistance was 13.9 °C/W, which is comparable to that of the SiC TO220 device (12.5 °C/W). On the other hand, corundum-structured α-(Rh,Ga)2O3 showed p-type conductivity, which was confirmed by Hall effect measurements. The Hall coefficient, carrier density, and mobility were 8.22 cm3/C, 7.6 × 1017/cm3, and 1.0 cm2 V-1 s-1, respectively. These values were acceptable for the p-type layer of pn diodes based on α-Ga2O3.

  19. Electrosynthesis of hydrogen peroxide via the reduction of oxygen assisted by power ultrasound.

    PubMed

    González-García, José; Banks, Craig E; Sljukić, Biljana; Compton, Richard G

    2007-04-01

    The electrosynthesis of hydrogen peroxide using the oxygen reduction reaction has been studied in the absence and presence of power ultrasound in a non-optimized sono-electrochemical flow reactor (20 cm cathodic compartment length with 6.5 cm inner diameter) with reticulated vitreous glassy carbon electrode (30 x 40 x 10 mm, 10 ppi, 7 cm(2)cm(-3)) as the cathode. The effect of several electrochemical operational variables (pH, volumetric flow, potential) and of the sono-electrochemical parameters (ultrasound amplitude and horn-to-electrode distance) on the cumulative concentration of hydrogen peroxide and current efficiency of the electrosynthesis process have been explored. The application of power ultrasound was found to increase both the cumulative concentration of hydrogen peroxide and the current efficiency. The application of ultrasound is therefore a promising approach to the increased efficiency of production of hydrogen peroxide by electrosynthesis, even in the solutions of lower pH (<12). The results demonstrate the feasibility of at-site-of-use green synthesis of hydrogen peroxide.

  20. Design and Assembly of the Magnetized Dusty Plasma Experiment (MDPX)

    NASA Astrophysics Data System (ADS)

    Fisher, Ross; Artis, Darrick; Lynch, Brian; Wood, Keith; Shaw, Joseph; Gilmore, Kevin; Robinson, Daniel; Polka, Christian; Konopka, Uwe; Thomas, Edward; Merlino, Robert; Rosenberg, Marlene

    2013-10-01

    Over the last two years, the Magnetized Dusty Plasma Experiment (MDPX) has been under construction at Auburn University. This new research device, whose assembly will be completed in late Summer, 2013, uses a four-coil, superconducting, high magnetic field system (|B | >= 4 Tesla) to investigate the confinement, charging, transport, and instabilities in a dusty plasma. A new feature of the MDPX device is the ability to operate the magnetic coils independently to allow a variety of magnetic configurations from highly uniform to quadrapole-like. Envisioned as a multi-user facility, the MDPX device features a cylindrical vacuum vessel whose primary experimental region is an octagonal chamber that has a 35.5 cm inner diameter and is 19 cm tall. There is substantial diagnostics and optical access through eight, 10.2 cm × 12.7 cm side ports. The chamber can also be equipped with two 15.2 cm diameter, 76 cm long extensions to allow long plasma column experiments, particularly long wavelength dust wave studies. This presentation will discuss the final design, assembly, and installation of the MDPX device and will describe its supporting laboratory facility. This work is supported by a National Science Foundation - Major Research Instrumentation (NSF-MRI) award, PHY-1126067.

  1. Development of a high efficiency thin silicon solar cell

    NASA Technical Reports Server (NTRS)

    Storti, G.; Culik, J.; Wrigley, C.

    1980-01-01

    Significant improvements in open-circuit voltage and conversion efficiency, even on relatively high bulk resistivity silicon, were achieved by using a screen-printed aluminum paste back surface field. A 4 sq cm 50 micron m thick cell was fabricated from textured 10 omega-cm silicon which had an open-circuit voltage of 595 mV and AMO conversion efficiency at 25 C of 14.3%. The best 4 sq cm 50 micron thick cell (2 omega-cm silicon) produced had an open-circuit voltage of 607 mV and an AMO conversion efficiency of 15%. Processing modifications are described which resulted in better front contact integrity and reduced breakage. These modifications were utilized in the thin cell pilot line to fabricate 4 sq cm cells with an average AMO conversion efficiency at 25 C of better than 12.5% and with lot yields as great as 51% of starts; a production rate of 10,000 cells per month was demonstrated. A pilot line was operated which produced large area (25 cm) ultra-thin cells with an average AMO conversion efficiency at 25 deg of better than 11.5% and a lot yield as high as 17%.

  2. Effect of lung resection on pleuro-pulmonary mechanics and fluid balance.

    PubMed

    Salito, C; Bovio, D; Orsetti, G; Salati, M; Brunelli, A; Aliverti, A; Miserocchi, G

    2016-01-15

    The aim of the study was to determine in human patients the effect of lung resection on lung compliance and on pleuro-pulmonary fluid balance. Pre and post-operative values of compliance were measured in anesthetized patients undergoing resection for lung cancer (N=11) through double-lumen bronchial intubation. Lung compliance was measured for 10-12 cm H2O increase in alveolar pressure from 5 cm H2O PEEP in control and repeated after resection. No air leak was assessed and pleural fluid was collected during hospital stay. A significant negative correlation (r(2)=0.68) was found between compliance at 10 min and resected mass. Based on the pre-operative estimated lung weight, the decrease in compliance following lung resection exceeded by 10-15% that expected from resected mass. Significant negative relationships were found by relating pleural fluid drainage flow to the remaining lung mass and to post-operative lung compliance. Following lung re-expansion, data suggest a causative relationship between the decrease in compliance and the perturbation in pleuro-pulmonary fluid balance. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Performance and emissions of a catalytic reactor with propane, diesel, and Jet A fuels

    NASA Technical Reports Server (NTRS)

    Anderson, D. N.

    1977-01-01

    Tests were made to determine the performance and emissions of a catalytic reactor operated with propane, No. 2 diesel, and Jet A fuels. A 12-cm diameter and 16-cm long catalytic reactor using a proprietary noble metal catalyst was operated at an inlet temperature of 800 K, a pressure of 300,000 Pa and reference velocities of 10 to 15 m/s. No significant differences between the performance of the three fuels were observed when 98.5 percent purity propane was used. The combustion efficiency for 99.8-percent purity propane tested later was significantly lower, however. The diesel fuel contained 135 ppm of bound nitrogen and consequently produced the highest NOx emissions of the three fuels. As much as 85 percent of the bound nitrogen was converted to NOx. Steady-state emissions goals based on half the most stringent proposed automotive standards were met when the reactor was operated at an adiabatic combustion temperature higher than 1350 K with all fuels except the 99.8-percent purity propane. With that fuel, a minimum temperature of 1480 K was required.

  4. Large area silicon sheet by EFG

    NASA Technical Reports Server (NTRS)

    Kalejs, J. P.

    1982-01-01

    Work carried out on the JPL Flat Plate Solar Array Project, for the purpose of developing a method for silicon ribbon production by Edge-defined Film-fed Growth (EEG) for use as low-cost substrate material in terrestrial solar cell manufacture, is described. A multiple ribbon furnace unit that is designed to operate on a continuous basis for periods of at least one week, with melt replenishment and automatic ribbon width control, and to produce silicon sheet at a rate of one square meter per hour, was constructed. Program milestones set for single ribbon furnace operation to demonstrate basic EEG system capabilities with respect to growth speed, thickness and cell performance were achieved for 10 cm wide ribbon: steady-state growth at 4 cm/min and 200 micron thickness over periods of an hour and longer was made routine, and a small area cell efficiency of 13+% demonstrated. Large area cells of average efficiency of 10 to 11%, with peak values of 11 to 12% were also achieved. The integration of these individual performance levels into multiple ribbon furnace operation was not accomplished.

  5. Thickness-dependent multiferroic behavior of BiFe0.75Cr0.25O3 films over Pt(111)/Ti/SiO2/Si substrate

    NASA Astrophysics Data System (ADS)

    William, R. V.; Sivaprakash, P.; Marikani, A.; Reddy, V. Raghavendra; Arumugam, S.

    2018-02-01

    We present here the experimental results of BiFe0.75Cr0.25O3 (BFCO) thin film deposited by sol-gel spin coating technique directly on Pt(111)/Ti/SiO2/Si substrate at different thicknesses. The crystal structure of BFCO has been investigated using X-ray diffraction which acts as a double perovskite structure with high crystallinity obtained at 400 °C. Further microscopic studies such as scanning electron microscope (SEM) with EDAX, transmission electron microscope (TEM) were also used in identifying the grain size and particle distribution over Pt (111) substrate. Atomic force microscopy (AFM) on the films at a different thickness (- 80 to - 250 nm) reveals that the surface roughness and other amplitude parameters increases with the increase in thickness signifying an increase of grain size with thickness. Increase in grain size and substrate clamping effect between the BFCO film and the substrate induces change in ferroelectric polarization and dielectric properties in relation to thickness effect. Similarly, decrease in magnetization from 9.241 emu/cm3 (- 80 nm) to 5.7791 emu/cm3 (- 250 nm) is attributed to the formation of anti-sites and anti-phase boundaries in the films. In addition, temperature dependence of magnetization reveals ferromagnetic super-exchange interaction of BFCO which is unlike the spin structure of antiferromagnetic BiFeO3.

  6. Vertical Alignment of Single-Walled Carbon Nanotubes on Nanostructure Fabricated by Atomic Force Microscope

    DTIC Science & Technology

    2007-05-01

    SWNTs by blending them with liquid crystal,7 assem- bling SWNT films by Langmuir - Blodgett methods,8 and chemical assembly of SWNTs on a large substrate...Ulman, A. An Introduction to Ultrathin Organic Films from Langmuir - Blodgett to Self-Assembly. Academic: New York, (1991). [10] Moon, J.H., Shin, J.W...Fang, J. Langmuir , 16, 2651, (2000). [8] FT-IR data (Bruker IFS48, KBr Pellet): 1720 cm-1 (νC=O, SWNT-COOH) and 1770 cm-1 (νC=O, SWNT- COCl). [9

  7. Pulmonary microvascular dysfunction and pathological changes induced by blast injury in a rabbit model.

    PubMed

    Wu, Si Yu; Han, Geng Fen; Kang, Jian Yi; Zhang, Liang Chao; Wang, Ai Min; Wang, Jian Min

    2016-09-01

    Vascular leakage has been proven to play a critical role in the incidence and development of explosive pulmonary barotrauma. Quantitatively investigated in the present study was the severity of vascular leakage in a gradient blast injury series, as well as ultrastructural evidence relating to pulmonary vascular leakage. One hundred adult male New Zealand white rabbits were randomly divided into 5 groups according to distance from the detonator (10 cm, 15 cm, 20 cm, 30 cm, and sham control). Value of pulmonary vascular leakage was monitored by a radioactive 125I-albumin labeling method. Pathological changes caused by the blast wave were examined under light and electron microscopes. Transcapillary escape rate of 125I-albumin and residual radioactivity in both lungs increased significantly at the distances of 10 cm, 15 cm, and 20 cm, suggesting increased severity of vascular leakage in these groups. Ultrastructural observation showed swelling of pulmonary capillary endothelial cells and widened gap between endothelial cells in the 10-cm and 15-cm groups. Primary blast wave can result in pulmonary capillary blood leakage. Blast wave can cause swelling of pulmonary capillary endothelial cells and widened gap between endothelial cells, which may be responsible for pulmonary vascular leakage.

  8. Measurement of laser absorptivity for operating parameters characteristic of laser drilling regime

    NASA Astrophysics Data System (ADS)

    Schneider, M.; Berthe, L.; Fabbro, R.; Muller, M.

    2008-08-01

    Laser drilling in the percussion regime is commonly used in the aircraft industry to drill sub-millimetre holes in metallic targets. Characteristic laser intensities in the range of 10 MW cm-2 are typically employed for drilling metallic targets. With these intensities the temperature of the irradiated matter is above the vaporization temperature and the drilling process is led by hydrodynamic effects. Although the main physical processes involved are identified, this process is not correctly understood or completely controlled. A major characteristic coefficient of laser-matter interaction for this regime, which is the absorptivity of the laser on the irradiated surface, is still unknown, because of the perturbing effects due to laser beam geometrical trapping inside the drilled hole. So, by using time resolved experiments, this study deals with the direct measurement of the variation of the intrinsic absorption of aluminium, nickel and steel materials, as a function of the incident laser intensity up to 20 MW cm-2. We observe that for this incident intensity, the absorptivity can reach up to 80%. This very high and unexpected value is discussed by considering the microscopic behaviour of the heated matter near the vapour-liquid interface that undergoes possible Rayleigh-Taylor instability or volume absorption.

  9. First Clinical Applications of a High-Definition Three-Dimensional Exoscope in Pediatric Neurosurgery.

    PubMed

    Beez, Thomas; Munoz-Bendix, Christopher; Beseoglu, Kerim; Steiger, Hans-Jakob; Ahmadi, Sebastian A

    2018-01-24

    The ideal visualization tools in microneurosurgery should provide magnification, illumination, wide fields of view, ergonomics, and unobstructed access to the surgical field. The operative microscope was the predominant innovation in modern neurosurgery. Recently, a high-definition three-dimensional (3D) exoscope was developed. We describe the first applications in pediatric neurosurgery. The VITOM 3D exoscope (Karl Storz GmbH, Tuttlingen, Germany) was used in pediatric microneurosurgical operations, along with an OPMI PENTERO operative microscope (Carl Zeiss AG, Jena, Germany). Experiences were retrospectively evaluated with five-level Likert items regarding ease of preparation, image definition, magnification, illumination, field of view, ergonomics, accessibility of the surgical field, and general user-friendliness. Three operations were performed: supratentorial open biopsy in the supine position, infratentorial brain tumor resection in the park bench position, and myelomeningocele closure in the prone position. While preparation and image definition were rated equal for microscope and exoscope, the microscope's field of view, illumination, and user-friendliness were considered superior, while the advantages of the exoscope were seen in ergonomics and the accessibility of the surgical field. No complications attributed to visualization mode occurred. In our experience, the VITOM 3D exoscope is an innovative visualization tool with advantages over the microscope in ergonomics and the accessibility of the surgical field. However, improvements were deemed necessary with regard to field of view, illumination, and user-friendliness. While the debate of a "perfect" visualization modality is influenced by personal preference, this novel visualization device has the potential to become a valuable tool in the neurosurgeon's armamentarium.

  10. Efficient Conversion of Lignin to Electricity Using a Novel Direct Biomass Fuel Cell Mediated by Polyoxometalates at Low Temperatures.

    PubMed

    Zhao, Xuebing; Zhu, J Y

    2016-01-01

    A novel polyoxometalates (POMs) mediated direct biomass fuel cell (DBFC) was used in this study to directly convert lignin to electricity at low temperatures with high power output and Faradaic efficiency. When phosphomolybdic acid H3 PMo12 O40 (PMo12) was used as the electron and proton carrier in the anode solution with a carbon electrode, and O2 was directly used as the final electron acceptor under the catalysis of Pt, the peak power density reached 0.96 mW cm(-2), 560 times higher than that of phenol-fueled microbial fuel cells (MFCs). When the cathode reaction was catalyzed by PMo12, the power density could be greatly enhanced to 5 mW cm(-2). Continuous operation demonstrated that this novel fuel cell was promising as a stable electrochemical power source. Structure analysis of the lignin indicated that the hydroxyl group content was reduced whereas the carbonyl group content increased. Both condensation and depolymerization takes place during the PMo12 oxidation of lignin. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Apollo 12 Astronauts Peer Out of the Mobile Quarantine Facility

    NASA Technical Reports Server (NTRS)

    1969-01-01

    The smiling Apollo 12 astronauts peer out of the window of the mobile quarantine facility aboard the recovery ship, USS Hornet. Pictured (Left to right) are Spacecraft Commander, Charles Conrad; Command Module (CM) Pilot, Richard Gordon; and Lunar Module (LM) Pilot, Alan L. Bean. The crew were housed in the quarantine facility immediately after the Pacific recovery operation took place. The second manned lunar landing mission, Apollo 12 launched from launch pad 39-A at Kennedy Space Center in Florida on November 14, 1969 via a Saturn V launch vehicle. The Saturn V vehicle was developed by the Marshall Space Flight Center (MSFC) under the direction of Dr. Wernher von Braun. The LM, Intrepid, landed astronauts Conrad and Bean on the lunar surface in what's known as the Ocean of Storms while astronaut Richard Gordon piloted the CM, Yankee Clipper, in a parking orbit around the Moon. Lunar soil activities included the deployment of the Apollo Lunar Surface Experiments Package (ALSEP), finding the unmanned Surveyor 3 that landed on the Moon on April 19, 1967, and collecting 75 pounds (34 kilograms) of rock samples. Apollo 12 returned safely to Earth on November 24, 1969.

  12. Single- and two-color infrared focal plane arrays made by MBE in HgCdTe

    NASA Astrophysics Data System (ADS)

    Zanatta, Jean-Paul; Ferret, P.; Loyer, R.; Petroz, G.; Cremer, S.; Chamonal, Jean-Paul; Bouchut, Philippe; Million, Alain; Destefanis, Gerard L.

    2000-12-01

    We present here recent developments obtained at LETI infrared laboratory in the field of infrared detectors made in HgCdTe material and using the molecular beam epitaxial growth technique (MBE). We discuss the metallurgical points (growth temperature and flux control) that lead to achieve excellent quality epitaxial layers grown by MBE. We show a run-to-run reproducibility measured on growth run of more than 15 layers. The crystalline quality, surface morphology, and composition uniformity are excellent. The etch pits density (EPD) are in the low 105.cm-2 when HgCdTe grows on a CdZnTe substrate. Transport properties reveal a low n-type carrier concentration in the 1014 to 1015.cm-3 range with a carrier mobility in excess of 105 cm2/V/sec at 77K for epilayers grown with 10 micrometers cutoff wavelength. We describe the performances of several kinds of our HgCdTe- MBE devices: single color MWIR and LWIR detectors on HgCdTe/CdZnTe operating at 77K in respectively (3-5 micrometers ) and (8-12 micrometers ) wavelength range; single color MWIR detectors on HgCdTe grown on germanium heterosubstrate operating at 77K in the (3-5 micrometers ) wavelength range; two color HgCdTe detectors operating within the MWIR (3-5 micrometers ) band.

  13. Using the scanning electron microscope on the production line to assure quality semiconductors

    NASA Technical Reports Server (NTRS)

    Adolphsen, J. W.; Anstead, R. J.

    1972-01-01

    The use of the scanning electron microscope to detect metallization defects introduced during batch processing of semiconductor devices is discussed. A method of determining metallization integrity was developed which culminates in a procurement specification using the scanning microscope on the production line as a quality control tool. Batch process control of the metallization operation is monitored early in the manufacturing cycle.

  14. Wakata performs microscopic analysis of the NanoRacks Module-38 Petri Dishes

    NASA Image and Video Library

    2014-01-13

    ISS038-E-029082 (12 Jan. 2014) --- Japan Aerospace Exploration Agency astronaut Koichi Wakata, Expedition 38 flight engineer, performs microscopic analysis of the NanoRacks Module-38 Petri Dishes, using Celestron Reflective Microscope, in the Kibo laboratory of the International Space Station. These Module-38 experiments are designed by students as part of a competition sponsored by the International Space School Educational Trust (ISSET). This experiment examines three-dimensional growth of slime mold in petri dishes utilizing the NanoRacks Microscopes Facility.

  15. First, keep it safe: Integration of a complementary medicine service within a hospital.

    PubMed

    Schiff, Elad; Levy, Ilana; Arnon, Zahi; Ben-Arye, Eran; Attias, Samuel

    2018-05-01

    This paper sought to explore risk/safety considerations associated with the integration of a complementary medicine (CM) service within a public academic medical centre in Israel. We reviewed various sources pertaining to the CM service (interviews with CM staff, patients' electronic charts, service guidelines, correspondence with hospital administration) and conducted a thematic analysis to evaluate safety-related incidents during the 7 years of operation. In addition, we systematically assessed the charts for reports of treatment-associated adverse effects, which were documented in an obligatory field on treatment reports. After reviewing transcripts of interviews with 12 CM practitioners and with the director and vice-director of the CM service as well as transcripts of 8560 consultations that included 7383 treatments, we categorised 3 major domains of CM safety management: (i) prevention of safety-related incidents by appropriate selection of CM practitioners and modalities, (ii) actual adverse incidents and (iii) prevention of their recurrence using both hospital and CM service safety protocols. CM staff reported 5 categories of adverse incidents, most of which were minor. Twenty-nine adverse incidents were documented in the 7383 treatment sessions (0.4%). Safety management needs to be addressed both before introducing CM services in hospitals and throughout their integration. Important considerations for the safe integration of CM practices in the hospital include communication between CM and conventional practitioners, adherence to hospital safety rules, implementing a systematic approach for detecting and reporting safety-related incidents and continuous adaptation of the CM service safety protocols. © 2018 John Wiley & Sons Ltd.

  16. Impact of Microscope-Integrated OCT on Ophthalmology Resident Performance of Anterior Segment Surgical Maneuvers in Model Eyes.

    PubMed

    Todorich, Bozho; Shieh, Christine; DeSouza, Philip J; Carrasco-Zevallos, Oscar M; Cunefare, David L; Stinnett, Sandra S; Izatt, Joseph A; Farsiu, Sina; Mruthyunjaya, Privthi; Kuo, Anthony N; Toth, Cynthia A

    2016-07-01

    The integration of swept-source optical coherence tomography (SS-OCT) into the operating microscope enables real-time, tissue-level three-dimensional (3D) imaging to aid in ophthalmic microsurgery. In this prospective randomized controlled study, we evaluated the impact of SS microscope-integrated OCT (MI-OCT) on ophthalmology residents' performance of ophthalmic microsurgical maneuvers. Fourteen ophthalmology residents from a single institution were stratified by year of training and randomized to perform four anterior segment surgical maneuvers on porcine eyes with (MI-OCT+) or without (MI-OCT-) direct intraoperative OCT guidance. Subsequently, both groups repeated the same maneuvers without MI-OCT feedback to test whether initial MI-OCT experience affected subsequent surgical performance. Finally, the MI-OCT- group was crossed over and allowed to repeat the same maneuvers with direct MI-OCT guidance. Each resident completed a survey at the completion of the study. With direct MI-OCT feedback, residents demonstrated enhanced performance in depth-based anterior segment maneuvers (corneal suture passes at 50% and 90% depth and corneal laceration repair) compared with the residents operating without MI-OCT. Microscope-integrated OCT+ residents continued to outperform the controls when both groups subsequently operated without MI-OCT. For clear corneal wound geometry, there was no statistically significant effect of MI-OCT as applied in this study. Overall, the resident surgeons rated their subjective experience of using MI-OCT very favorably. Microscope-integrated OCT feedback enhances performance of ophthalmology residents in select anterior segment surgical maneuvers. Microscope-integrated OCT represents a valuable tool in the surgical education of ophthalmology residents.

  17. Multispectral digital lensless holographic microscopy: from femtosecond laser to white light LED

    NASA Astrophysics Data System (ADS)

    Garcia-Sucerquia, J.

    2015-04-01

    The use of femtosecond laser radiation and super bright white LED in digital lensless holographic microscopy is presented. For the ultrafast laser radiation two different configurations of operation of the microscope are presented and the dissimilar performance of each one analyzed. The microscope operating with a super bright white light LED in combination with optical filters shows very competitive performance as it is compared with more expensive optical sources. The broadband emission of both radiation sources allows the multispectral imaging of biological samples to obtain spectral responses and/or full color images of the microscopic specimens; sections of the head of a Drosophila melanogaster fly are imaged in this contribution. The simple, solid, compact, lightweight, and reliable architecture of digital lensless holographic microscopy operating with broadband light sources to image biological specimens exhibiting micrometer-sized details is evaluated in the present contribution.

  18. Saturn Apollo Program

    NASA Image and Video Library

    1969-11-24

    The smiling Apollo 12 astronauts peer out of the window of the mobile quarantine facility aboard the recovery ship, USS Hornet. Pictured (Left to right) are Spacecraft Commander, Charles Conrad; Command Module (CM) Pilot, Richard Gordon; and Lunar Module (LM) Pilot, Alan L. Bean. The crew were housed in the quarantine facility immediately after the Pacific recovery operation took place. The second manned lunar landing mission, Apollo 12 launched from launch pad 39-A at Kennedy Space Center in Florida on November 14, 1969 via a Saturn V launch vehicle. The Saturn V vehicle was developed by the Marshall Space Flight Center (MSFC) under the direction of Dr. Wernher von Braun. The LM, Intrepid, landed astronauts Conrad and Bean on the lunar surface in what’s known as the Ocean of Storms while astronaut Richard Gordon piloted the CM, Yankee Clipper, in a parking orbit around the Moon. Lunar soil activities included the deployment of the Apollo Lunar Surface Experiments Package (ALSEP), finding the unmanned Surveyor 3 that landed on the Moon on April 19, 1967, and collecting 75 pounds (34 kilograms) of rock samples. Apollo 12 returned safely to Earth on November 24, 1969.

  19. Stimulated penetrating keratoplasty using real-time virtual intraoperative surgical optical coherence tomography

    PubMed Central

    Lee, Changho; Kim, Kyungun; Han, Seunghoon; Kim, Sehui; Lee, Jun Hoon; Kim, Hong kyun; Kim, Chulhong; Jung, Woonggyu; Kim, Jeehyun

    2014-01-01

    Abstract. An intraoperative surgical microscope is an essential tool in a neuro- or ophthalmological surgical environment. Yet, it has an inherent limitation to classify subsurface information because it only provides the surface images. To compensate for and assist in this problem, combining the surgical microscope with optical coherence tomography (OCT) has been adapted. We developed a real-time virtual intraoperative surgical OCT (VISOCT) system by adapting a spectral-domain OCT scanner with a commercial surgical microscope. Thanks to our custom-made beam splitting and image display subsystems, the OCT images and microscopic images are simultaneously visualized through an ocular lens or the eyepiece of the microscope. This improvement helps surgeons to focus on the operation without distraction to view OCT images on another separate display. Moreover, displaying the OCT live images on the eyepiece helps surgeon’s depth perception during the surgeries. Finally, we successfully processed stimulated penetrating keratoplasty in live rabbits. We believe that these technical achievements are crucial to enhance the usability of the VISOCT system in a real surgical operating condition. PMID:24604471

  20. Virtual tape measure for the operating microscope: system specifications and performance evaluation.

    PubMed

    Kim, M Y; Drake, J M; Milgram, P

    2000-01-01

    The Virtual Tape Measure for the Operating Microscope (VTMOM) was created to assist surgeons in making accurate 3D measurements of anatomical structures seen in the surgical field under the operating microscope. The VTMOM employs augmented reality techniques by combining stereoscopic video images with stereoscopic computer graphics, and functions by relying on an operator's ability to align a 3D graphic pointer, which serves as the end-point of the virtual tape measure, with designated locations on the anatomical structure being measured. The VTMOM was evaluated for its baseline and application performances as well as its application efficacy. Baseline performance was determined by measuring the mean error (bias) and standard deviation of error (imprecision) in measurements of non-anatomical objects. Application performance was determined by comparing the error in measuring the dimensions of aneurysm models with and without the VTMOM. Application efficacy was determined by comparing the error in selecting the appropriate aneurysm clip size with and without the VTMOM. Baseline performance indicated a bias of 0.3 mm and an imprecision of 0.6 mm. Application bias was 3.8 mm and imprecision was 2.8 mm for aneurysm diameter. The VTMOM did not improve aneurysm clip size selection accuracy. The VTMOM is a potentially accurate tool for use under the operating microscope. However, its performance when measuring anatomical objects is highly dependent on complex visual features of the object surfaces. Copyright 2000 Wiley-Liss, Inc.

  1. Saturn Apollo Program

    NASA Image and Video Library

    1969-11-24

    Aboard the recovery ship, USS Hornet, Apollo 12 astronauts wave to the crowd as they enter the mobile quarantine facility. The recovery operation took place in the Pacific Ocean after the splashdown of the Command Module capsule. Navy para-rescue men recovered the capsule housing the 3-man Apollo 12 crew. The second manned lunar landing mission, Apollo 12 launched from launch pad 39-A at Kennedy Space Center in Florida on November 14, 1969 via a Saturn V launch vehicle. The Saturn V was developed by the Marshall Space Flight Center (MSFC) under the direction of Dr. Wernher von Braun. Aboard Apollo 12 was a crew of three astronauts: Alan L. Bean, pilot of the Lunar Module (LM), Intrepid; Richard Gordon, pilot of the Command Module (CM), Yankee Clipper; and Spacecraft Commander Charles Conrad. The LM, Intrepid, landed astronauts Conrad and Bean on the lunar surface in what’s known as the Ocean of Storms while astronaut Richard Gordon piloted the CM, Yankee Clipper, in a parking orbit around the Moon. Lunar soil activities included the deployment of the Apollo Lunar Surface Experiments Package (ALSEP), finding the unmanned Surveyor 3 that landed on the Moon on April 19, 1967, and collecting 75 pounds (34 kilograms) of rock samples. Apollo 12 safely returned to Earth on November 24, 1969.

  2. Assessment of incomplete clipping of aneurysms intraoperatively by a near-infrared indocyanine green-video angiography (Niicg-Va) integrated microscope.

    PubMed

    Imizu, S; Kato, Y; Sangli, A; Oguri, D; Sano, H

    2008-08-01

    The objective of this article was to assess the clinical use and the completeness of clipping with total occlusion of the aneurysmal lumen, real-time assessment of vascular patency in the parent, branching and perforating vessels, intraoperative assessment of blood flow, image quality, spatial resolution and clinical value in difficult aneurysms using near infrared indocyanine green video angiography integrated on to an operative Pentero neurosurgical microscope (Carl Zeiss, Oberkochen Germany). Thirteen patients with aneurysms were operated upon. An infrared camera with near infrared technology was adapted on to the OPMI Pentero microscope with a special filter and infrared excitation light to illuminate the operating field which was designed to allow passage of the near infrared light required for excitation of indocyanine green (ICG) which was used as the intravascular marker. The intravascular fluorescence was imaged with a video camera attached to the microscope. ICG fluorescence (700-850 nm) from a modified microscope light source on to the surgical field and passage of ICG fluorescence (780-950 nm) from the surgical field, back into the optical path of the microscope was used to detect the completeness of aneurysmal clipping Incomplete clipping in three patients (1 female and 2 males) with unruptured complicated aneurysms was detected using indocyanine green video angiography. There were no adverse effects after injection of indocyanine green. The completeness of clipping was inadequately detected by Doppler ultrasound miniprobe and rigid endoscopy and was thus complemented by indocyanine green video angiography. The operative microscope-integrated ICG video angiography as a new intraoperative method for detecting vascular flow, was found to be quick, reliable, cost-effective and possibly a substitute or adjunct for Doppler ultrasonography or intraoperative DSA, which is presently the gold standard. The simplicity of the method, the speed with which the investigation can be performed, the quality of the images, and the outcome of surgical procedures have all reduced the need for angiography. This technique may be useful during routine aneurysm surgery as an independent form of angiography and/or as an adjunct to intraoperative or postoperative DSA.

  3. [Effectiveness of dorsal metacarpal island flap for treating scar contracture of finger web].

    PubMed

    Qian, Jun; Rui, Yongjun; Zhang, Quanrong; Xue, Mingyu; Zhang, Zhihai

    2011-11-01

    To investigate the effectiveness of dorsal metacarpal island flap for treating scar contracture of the finger web. Between June 2009 and December 2010, 10 patients with scar contracture of the finger web were treated. There were 6 males and 4 females with an average age of 30 years (range, 14-57 years). Scar contracture was caused by injury in 8 cases, by burn in 1 case, and by operation in 1 case. The locations were the 1st web space in 1 case, the 2nd web space in 3 cases, the 3rd web space in 5 cases, and the 4th web space in 1 case. The disease duration was 3 to 9 months with an average of 5 months. The maximum abduction was 10-20 degrees. After web space scar release, the dorsal metacarpal island flap (3.5 cm x 1.2 cm-4.0 cm x 2.0 cm in size) was used to reconstruct web space (2.0 cm x 1.0 cm-3.0 cm x 1.8 cm in size). The donor site was directly sutured or repaired with local flaps. At 2 days after operation, necrosis occurred in 1 flap, which healed by extractive treatment. The other flaps survived and wound healed by first intention; all the flaps at donor sites survived and incision healed by first intention. Ten patients were followed up 6 to 15 months (mean, 9 months). The reconstructed web space had good appearance, the maximum abduction was 80 degrees in 1 case of the 1st web space scars contracture, and the maximum abduction was 35-45 degrees (mean, 40 degrees) in the other 9 cases. In 8 scar patients causing by injury, no scar contracture recurred during follow-up. It can achieve good results in appearance and function to use dorsal metacarpal island flap for treating scar contracture of the finger web.

  4. [APPLICATION OF PEDICLED LATISSIMUS DORSI KISS FLAP TO REPAIR CHEST WALL SKIN DEFECTS AFTER TUMOR RESECTION].

    PubMed

    Lü, Chunliu; Li, Zan; Zhou, Xiao; Song, Dajiang; Peng, Xiaowei; Zhou, Bo; Yang, Lichang

    2016-12-08

    To investigate the clinical value of pedicled latissimus dorsi Kiss flap in repairing chest wall large skin defect after tumor operation. A retrospective analysis was made on the clinical data from 15 cases of chest wall tumors treated between December 2010 and December 2015. There were 2 males and 13 females with an average age of 51.8 years (range, 43-60 years); there were 11 cases of locally advanced breast cancer, 3 cases of fibrosarcoma in chest wall, and 1 case of chest wall radiation ulcer with a median disease duration of 24.1 months (range, 6 months to 8 years). The area of skin defects was 17 cm×12 cm to 20 cm×18 cm after primary tumor resection; the pedicled latissimus dorsi Kiss flap was designed to repair wounds. The flap was a two-lobed flap at a certain angle on the surface of latissimus dorsi based on the thoracodorsal artery, with a size of 17 cm×6 cm to 20 cm×9 cm for each lobe. The donor site was sutured directly. Fourteen flaps survived with primary healing of wound; delayed healing was observed in 1 flap because of distal necrosis; and healing by first intention was obtained at the donor sites. The follow-up time was from 6 months to 3 years (mean, 21.6 months). The flap had good appearance with no bloated pedicle. The shoulder joint activities were normal. No local recurrence occurred, but distant metastasis in 2 cases. No obvious scar was found at donor sites. The application of pedicled latissimus dorsi Kiss flap to repair chest wall skin defects after tumor resection has important clinical value, because of the advatages of simple operation, minor donor site damage and rapid postoperative recovery, especially for late stage cancer patients.

  5. Systematic analysis of the scatter environment in clinical intra-operative high dose rate (IOHDR) brachytherapy

    NASA Astrophysics Data System (ADS)

    Oh, Moonseong

    Most brachytherapy planning systems are based on a dose calculation algorithm that assumes an infinite scatter environment surrounding the target volume and applicator. In intra-operative high dose rate brachytherapy (IOHDR) where treatment catheters are typically laid either directly on a tumor bed or within applicators that may have little or no scatter material above them, the lack of scatter from one side of the applicator can result in serious underdosage during treatment. Therefore, full analyses of the physical processes such as the photoelectric effect, Rayleigh, and Compton scattering that contribute to dosimetric errors have to be investigated and documented to result in more accurate treatment delivery to patients undergoing IOHDR procedures. Monte Carlo simulation results showed the Compton scattering effect is about 40 times more probable than photoelectric effect for the treated areas of single source, 4 x 4, and 2 x 4 cm2. Also, the dose variations with and without photoelectric effect were 0.3 ˜ 0.7%, which are within the uncertainty in Monte Carlo simulations. Also, Monte Carlo simulation studies were done to verify the following experimental results for quantification of dosimetric errors in clinical IOHDR brachytherapy. The first experimental study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in IOHDR brachytherapy. Treatment plans were developed for 3 different treatment surface areas (4 x 4, 7 x 7, 12 x 12 cm2), each with prescription points located at 3 distances (0.5 cm, 1.0 cm, and 1.5 cm) from the source dwell positions. Measurements showed that the magnitude of the underdosage varies from about 8% to 13% of the prescription dose as the prescription depth is increased from 0.5 cm to 1.5 cm. This treatment error was found to be independent of the irradiated area and strongly dependent on the prescription distance. The study was extended to confirm the underdosage for various shape of treated area (especially, irregular shape), which can be applied in clinical cases. Treatment plans of 10 patients previously treated at Roswell Park Cancer Institute in Buffalo, which had irregular shapes of treated areas, were used. In IOHDR brachytherapy, a 2-dimensional (2-D) planar geometry is typically used without considering the curved shape of target surfaces. In clinical cases, this assumption of the planar geometry may cause the serious dose delivery errors to target volumes. The second study was performed to investigate the dose errors to curved surfaces. Seven rectangular shaped plans (five for 1.0 cm and two for 0.5 cm prescription depth) and archived irregular shaped plans of 2 patients were analyzed. Cylindrical phantoms with six radii (ranged 1.35 to 12.5 cm) were used to simulate the treatment planning geometries, which were calculated in 2-D plans. Actual doses delivered to prescription points were over-estimated up to 15% on the concave side of curved applicators for all cylindrical phantoms with 1.0 cm prescription depth. Also, delivered doses decreased by up to 10% on the convex side of curved applicators for small treated areas (≤ 5catheters), but interestingly, any dose dependence was not shown with large treated areas. Our measurements have shown inaccuracy in dose delivery when the original planar treatment plan was delivered in a curved applicator setting. Dose errors arising due to the tumor curvature may be significant in a clinical set up and merit attention during planning.

  6. Performance of an ion-cyclotron-wave plasma apparatus operated in the radiofrequency sustained mode

    NASA Technical Reports Server (NTRS)

    Swett, C. C.; Woollett, R. R.

    1973-01-01

    An experimental study has been made of an ion-cyclotron-wave apparatus operated in the RF-sustained mode, that is, a mode in which the Stix RF coil both propagates the waves and maintains the plasma. Problems associated with this method of operation are presented. Some factors that are important to the coupling of RF power are noted. In general, the wave propagation and wave damping data agree with theory. Some irregularities in wave fields are observed. Maximum ion temperature is 870 eV at a density of five times 10 to the 12th power cu cm and RF power of 90 kW. Coupling efficiency is 70 percent.

  7. Liquid–liquid mixing studies in annular centrifugal contactors comparing stationary mixing vane options

    DOE PAGES

    Wardle, Kent E.

    2015-09-11

    Comparative studies of multiphase operation of an annular centrifugal contactor show the impact of housing stationary mixing vane configuration. A number of experimental results for several different mixing vane options are reported for operation of a 12.5 cm engineering-scale contactor unit. Fewer straight vanes give greater mixing-zone hold-up compared to curved vanes. Quantitative comparison of droplet size distribution also showed a significant decrease in mean diameter for four straight vanes versus eight curved vanes. This set of measurements gives a compelling case for careful consideration of mixing vane geometry when evaluating hydraulic operation and extraction process efficiency of annular centrifugalmore » contactors.« less

  8. Transoral robotic resection of a large schwannoma in the retropharyngeal space.

    PubMed

    Gungadeen, A; Lisseter, R; Manickavasagam, J; Paleri, V

    2016-04-01

    External approaches have been traditionally used for the complete excision of large retropharyngeal space lesions. This paper describes a case of a large schwannoma of the retropharyngeal space excised transorally with the use of a robotic system. This lesion measured 2.7 × 1.2 cm in axial dimensions and over 5.8 cm in craniocaudal length. The lesion was delivered en bloc with an intact capsule. No peri- or post-operative complications were encountered. The procedure allowed quick resumption of an oral diet and a return to normal activity for the patient. This is, to our knowledge, the first report of this technique used in the excision of a large retropharyngeal space mass.

  9. Sand filter clogging by septic tank effluent.

    PubMed

    Spychała, M; Błazejewski, R

    2003-01-01

    The aim of this study was to characterise conditions and factors affecting fine sand clogging by septic tank effluent on the basis of physical modelling. The physical model consisted of 12 sand columns dosed with sewage from one household (5 persons), preliminary treated in a septic tank. Hydraulic loadings of the sand filters were equal to 82 mm/d. The mean discharge from sand columns, measured as the effluent volume collected during 10 minutes, decreased significantly over the experiment period from 34 cm3/min in August 2000 to 20 cm3/min in August 2001 at the same temperature of about 20 degrees C. First the columns clogged almost completely after 480 days in December 2001, however six columns had remained unclogged till the end of the experiment (March 2002). The temperature had a significant impact on hydraulic conductivity. A vertical distribution of accumulated mass and biomass was investigated in partly clogged sand. Microscopic survey of the clogging layer showed a presence of live micro-organisms, residuals of dead micro-organisms, particularly pieces of small animal armour and many fibres. These particles accelerated the accumulation of solids in the upper clogging layer. The study indicated that temperature impact on the filter hydraulic conductivity was more significant for biological activity, than for sewage viscosity.

  10. [Skin graft combined with thorax wire fastening for repairing postoperative coloboma After resection of chest back giant nevus].

    PubMed

    Zhao, Weimin; Dai, Tao; Yuan, Depin; Zhang, Gongbao

    2011-11-01

    To observe the effectiveness of skin graft combined with thorax wire fastening for repairing postoperative coloboma after resection of chest back giant nevus. Between June 2007 and October 2010, 17 cases of chest back giant nevus were treated. There were 7 males and 10 females, aged from 3 years and 6 months to 15 years (mean, 8 years). The size of giant nevus was 20 cm x 12 cm to 60 cm x 50 cm. Two cases of them were ever treated by laser, while the others were never treated. The check before operation showed ulcer of the skin and effusion in 2 cases, hard skin in 3 cases, hair growth in 7 cases, and normal in 5 cases. Five cases had serious itch. After giant nevus was cut off, thorax wire was fastened to reduce the wound area, and then the intermediate split thickness skin graft of thigh was used to repair the wound. Comprehensive anti-scar treatment was given postoperatively. The wound size was (2 110.74 +/- 725.69) cm2 after resection of giant nevus, and was (1 624.94 +/- 560.57) cm2 after thorax wire fastening, showing significant difference (t = 9.006, P = 0.001). All the grafting skin survived; the incision and wound at donor site healed by first intention. The patients were followed up 6 months to 2 years (mean, 13 months). No scar proliferation or contracture occurred. The skin color and elasticity were similar to the normal skin; the nipple, navel, and other local apparatus were not shifted after operation. It can reduce donor site of skin and postoperative scar, and achieve satisfactory appearance to cover the wound by skin graft combined with thorax wire fastening after chest back giant nevus was cut off.

  11. Cross-sectional transmission electron microscopic study of irradiation induced nano-crystallization of nickel in a W/Ni multilayer.

    PubMed

    Bagchi, Sharmistha; Lalla, N P

    2008-06-11

    The present study reports the cross-sectional transmission electron microscopic investigations of swift heavy ion-irradiation induced nano-size recrystallization of Ni in a nearly immiscible W/Ni multilayer structure. Multilayer structures (MLS) of [W(25 Å)/Ni(25 Å)](10BL) were grown on Si-(100) substrate by the ion-beam sputtering technique. The as-synthesized MLS were subjected to 120 MeV-Au(9+) ion-irradiation to a fluence of ∼5 × 10(13) ions cm(-2). Wide-angle x-ray diffraction studies of pristine as well as irradiated W/Ni multilayers show deterioration of the superlattice structure, whereas x-ray reflectivity (XRR) measurement reveals a nearly unaffected microstructure after irradiation. Analysis of the XRR data using 'Parratt's formalism' does show a significant increase of W/Ni interface roughness. Cross-sectional transmission electron microscopy (TEM) studies carried out in diffraction and imaging modes (including bright-field and dark-field imaging), show that at high irradiation dose the intralayer microstructure of Ni becomes nano-crystalline (1-2 nm). During these irradiation induced changes of the intralayer microstructure, the interlayer definition of the W and Ni layers still remains intact. The observed nano-recrystallization of Ni has been attributed to competition between low miscibility of the W/Ni interface and the ion-beam induced mixing kinetics.

  12. Experience with integrally-cast compressor and turbine components for a small, low-cost, expendable-type turbojet engine

    NASA Technical Reports Server (NTRS)

    Dengler, R. P.

    1975-01-01

    Experiences with integrally-cast compressor and turbine components during fabrication and testing of four engine assemblies of a small (29 cm (11 1/2 in.) maximum diameter) experimental turbojet engine design for an expendable application are discussed. Various operations such as metal removal, welding, and re-shaping of these components were performed in preparation of full-scale engine tests. Engines with these components were operated for a total of 157 hours at engine speeds as high as 38,000 rpm and at turbine inlet temperatures as high as 1256 K (1800 F).

  13. 200 Deg C Demonstration Transformer Operates Efficiently at 50 kHz

    NASA Technical Reports Server (NTRS)

    Niedra, Janis M.; Schwarze, Gene E. (Technical Monitor)

    2003-01-01

    A compact, high temperature demonstration transformer was constructed, using a moly permalloy powder core and Teflon -insulated copper wire. At 50 kHz and 200 C, this 1:2 ratio transformer is capable of 98 percent efficiency when operating at a specific power of 6.1 kW/kg at 4 kW. This roughly 7 cm diameter transformer has a mass of 0.65 kg. Although Teflon is unstable above 200 C, about the same electrical performance was seen at 250 C. A plot of winding loss versus frequency illustrates the need to control these losses at high frequency.

  14. Trans-obturator vaginal tape (TOT) for female stress incontinence: one year follow-up in 120 patients.

    PubMed

    Roumeguère, Thierry; Quackels, Th; Bollens, R; de Groote, A; Zlotta, A; Bossche, M Vanden; Schulman, C

    2005-11-01

    The aim of this study was to evaluate the effectiveness of a new minimally invasive surgical procedure, the Trans-obturator Vaginal Tape (TOT) in the treatment of female urodynamic stress incontinence (USI) and to analyse functional results and quality of life after one year of follow up. 120 consecutive women with stress urinary incontinence underwent the procedure since February 2002 under general or loco-regional anesthesia. Minimum follow up was one year (range 12-30 months). Mean age was 58 years (range 31-86). 70% of the patients had pure USI. 5 patients were previously operated for USI. In 10 cases, concomitant repair of pelvic floor defects was mandatory. Collection of the data included operative time, pre- and post-operative complications. Patients were post-operatively assessed at one week, one month and one year. A validated urinary incontinence-specific measure of Quality of Life (QoL) questionnaire (Contilife) was sent and completed 12 months after surgery. The mean operative time was 12 min (range 6-30) with a catheterisation time of 0,9 day (range 0-2). No severe bleeding was observed. There were 13 minor lateral tears of the vagina without any sequelae. Three perforations of the urethra and one of the bladder occurred during the learning phase. In two cases a re-intervention was necessary for tape removal when the injury was not recognised during the procedure. Two transient urinary retention needed a supra pubic catheter and tape release. Eleven women presented transient voiding outflow obstruction. After one month, 93% patients were cured with no pad and a negative cough test with a full bladder. Uroflowmetry did not show any significant changes between pre- and post-operative time in all the population. De novo urgency occurred only in 2.5% and persistent dysuria (Qmax <10 ml/s and/or post-void residual volume >120 cc) in 4%. 80% of patients were completely dry after one year and 12% were greatly improved. According to the pre-operative maximal urethral closure pressure, continence rate was 86% above 30 cm H2O and 76% below 30 cm H2O respectively. Global satisfaction of women at 1 year was 78% with good scores based on daily and effort activities, self-image, emotional and sexual activities. TOT is a safe and effective new minimal invasive procedure for USI with a low rate of complications. To confirm the success of TOT, longer follow up in large population is mandatory to assess the reliability of this attractive technique.

  15. Placebo-controlled randomized clinical trial of the effect two different low-level laser therapies (LLLT)--intraoral and extraoral--on trismus and facial swelling following surgical extraction of the lower third molar.

    PubMed

    Aras, Mutan Hamdi; Güngörmüş, Metin

    2010-09-01

    The purpose of this study is to compare the effects of extraoral and intraoral low-level laser therapies (LLLT) on postoperative trismus and oedema following the removal of mandibular third molars. Forty-eight patients who were to undergo surgical removal of their lower third molars were studied. Patients were randomly allocated to one of three groups: extraoral LLLT, intraoral LLLT, or placebo. In the study, a Ga-Al-As diode laser device with a continuous wavelength of 808 nm was used, and the laser therapy was applied by using a 1 x 3-cm handpiece. The flat-top laser beam profile was used in this therapy. For both of the LLLT groups, laser energy was applied at 100 mW (0.1 W) for a total of 120 s (0.1 W x 120 s = 12 J). Patients in the extraoral-LLLT group (n = 16) received 12-J (4 J/cm(2)) low-level laser irradiation, and the laser was applied at the insertion point of the masseter muscle immediately after the operation. Patients in the intraoral-LLLT group (n = 16) received 12-J (4 J/cm(2)) low-level laser irradiation intraorally at the operation site 1 cm from the target tissue. In the placebo group (n = 16), the handpiece was inserted intraorally at the operation site and then was touched extraorally to the masseter muscle for 1 min at each site (120 s total), but the laser was not activated. The size of the interincisal opening and facial swelling were evaluated on the second and seventh postoperative days. At the second postoperative day, trismus (29.0 +/- 7.6 mm [p = 0.010]) and swelling (105.3 +/- 5.0 mm [p = 0.047]) in the extraoral-LLLT group were significantly less than in the placebo group (trismus: 21.1 +/- 7.6 mm, swelling: 109.1 +/- 4.4 mm). Trismus (39.6 +/- 9.0 mm [p = 0.002]) in the extraoral-LLLT group at the seventh postoperative day was also significantly less than in the placebo group (29.0 +/- 6.2 mm). However, at the seventh postoperative day in the intraoral-LLLT group, only trismus (35.6 +/- 8.5 [p = 0.002]) was significantly less than in the placebo group (29.0 +/- 6.2 mm). This study demonstrates that extraoral LLLT is more effective than intraoral LLLT for the reduction of postoperative trismus and swelling after extraction of the lower third molar.

  16. SLAC All Access: X-ray Microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Johanna; Liu, Yijin

    2012-08-14

    SLAC physicists Johanna Nelson and Yijin Liu give a brief overview of the X-ray microscope at the Stanford Synchrotron Radiation Lightsource (SSRL) that is helping improve rechargeable-battery technology by letting researchers peek into the inner workings of batteries as they operate.

  17. SLAC All Access: X-ray Microscope

    ScienceCinema

    Nelson, Johanna; Liu, Yijin

    2018-01-16

    SLAC physicists Johanna Nelson and Yijin Liu give a brief overview of the X-ray microscope at the Stanford Synchrotron Radiation Lightsource (SSRL) that is helping improve rechargeable-battery technology by letting researchers peek into the inner workings of batteries as they operate.

  18. A study on modification of nanoporous rice husk silica for hydrophobic nano filter.

    PubMed

    Kim, Hee Jin; So, Soo Jeong; Han, Chong Soo

    2010-05-01

    Nanoporous rice husk silica (RHS) was modified with alkylsilylation reagents, hexamethyldisilazane, diethoxydiphenylsilane, dichlorodimethylsilane and n-octodecyltrimethoxysilane. The silica samples were characterized with Raman spectrometer, thermal gravimetric analyzer, scanning electron microscope, nitrogen adsorption measurement and solid state nuclear magnetic resonance spectrometer. Raman spectra of the modified silica showed growth of the peaks of C-H stretching and CH3 bending at approximateluy 3000 cm(-1) and approximately 1500 cm(-1), respectively. Weight losses of 3 approximately 5% were observed in thermo gravimetric profiles of the modified silica. The microscopic shape of RHS, approximately 20 nm primary particles and their aggregates was almost not changed by the modification but there were colligations of the silica particles in the sample treated with dichlorodimethylsilane or diethoxydiphenylsilane. BET adsorption experiment showed the modification significantly decreased the mean pore size of the silica from approximately 5 nm to approximately 4 nm as well as the pore volume from 0.5 cm3/g to 0.4 cm3/g except the case of treatment with n-octodecyltrimethoxysilane. 29Si Solid NMR Spectra of the silica samples showed that there were decrease in the relative intensities of Q2 and Q3 peaks and large increments in Q4 after the modification except for the case of bulky n-octodecyltrimethoxysilane. From the results, it was concluded that the alkylsilylation reagents reacted with hydroxyl groups on the silica particles as well as in the nano pores while the size of the reagent molecule affected its diffusion and reaction with the hydroxyl groups in the pores.

  19. 0.4 Microns Spatial Resolution with 1 GHz (lambda = 30 cm) Evanescent Microwave Probe

    NASA Technical Reports Server (NTRS)

    Tabib-Azar, M.; Su, D.-P.; Pohar, A.; LeClair, S. R.; Ponchak, George E.

    1999-01-01

    In this article we describe evanescent field imaging of material nonuniformities with a record resolution of 0.4 microns at 1 GHz (lambda(sub g)/750000), using a resonant stripline scanning microwave probe. A chemically etched tip is used as a point-like evanescent field emitter and a probe-sample distance modulation is employed to improve the signal-to-noise ratio. Images obtained by evanescent microwave probe, by optical microscope, and by scanning tunneling microscope are presented for comparison. Probe was calibrated to perform quantitative conductivity measurements. The principal factors affecting the ultimate resolution of evanescent microwave probe are also discussed.

  20. Crystallization of the Zagami Shergottite: An Experimental Study

    NASA Technical Reports Server (NTRS)

    Lofgren, Gary E.; McCoy, Timothy J.

    2000-01-01

    Spherulites are usually rounded or spherical objects found in rhyolitic obsidian. They usually comprise acicular crystals of alkali feldspar that radiate from a single point. The radiating array of crystalline fibers typically have a similar crystallographic orientation such that a branch fiber departs slightly but appreciably from that of its parent fiber. Individual fibers range from 1 to several micrometers in diameter. The spherulites most likely form by heterogeneous nucleation on microscopic seed crystals, bubbles, or some other surface at high degrees of supercooling. They grow very rapidly stabilizing their fibrous habit and typically range in size from microscopic to a few cm in diameter.

  1. Anion-exchange membranes derived from quaternized polysulfone and exfoliated layered double hydroxide for fuel cells

    NASA Astrophysics Data System (ADS)

    Liu, Wan; Liang, Na; Peng, Pai; Qu, Rong; Chen, Dongzhi; Zhang, Hongwei

    2017-02-01

    Layered double hydroxides (LDH) are prepared by controlling urea assisted homogeneous precipitation conditions. Morphology and crystallinity of LDHs are confirmed by X-ray diffraction and scanning electron microscope. After LDHs are incorporated into quaternized polysulfone membranes, transmission electron microscope is used to observe the exfoliated morphology of LDH sheets in the membranes. The properties of the nanocomposite membranes, including water uptake, swelling ratio, mechanical property and ionic conductivity are investigated. The nanocomposite membrane containing 5% LDH sheets shows more balanced performances, exhibiting an ionic conductivity of 2.36×10-2 S cm-1 at 60 °C.

  2. Original technique for penile girth augmentation through porcine dermal acellular grafts: results in a 69-patient series.

    PubMed

    Alei, Giovanni; Letizia, Piero; Ricottilli, Francesco; Simone, Pierfranco; Alei, Lavinia; Massoni, Francesco; Ricci, Serafino

    2012-07-01

    Although different techniques for augmentation phalloplasty have been reported in the medical literature, this issue is still highly controversial, and none of the proposed procedures has been unanimously approved. The aim of this study is to describe an innovative surgical technique for penile girth augmentation with porcine dermal acellular grafts, through a small transverse incision at the penile base, along the penopubic junction. Between 2000 and 2009, 104 patients were referred to our institution for penile enhancement. After a preoperative psychosexual consultation and a general medical assessment, 69 patients were deemed suitable good candidates for surgery. The average penis circumference was measured at the mid-length of the penis and was 8.1 cm (5.4-10.7 cm) and 10.8 cm (6.5-15.8 cm) during flaccidity and erection, respectively. All patients received penile augmentation with porcine dermal acellular grafts. Results evaluation of an innovative technique for penile girth augmentation through exogenous porcine grafts and small penobubic incision. Postoperative measurements were performed at 6 and 12 months. At the 1-year follow-up, the average penis circumference was 11.3 cm (8.2-13.2 cm, 3.1 cm mean increase) during flaccidity and 13.2 cm (8.8-14.5 cm, 2.4 cm mean increase) during erection. No major complications occurred in the series. Minor complications were resolved with conservative treatment within 3 weeks. Sexual activity was resumed from 1 to 2 months after surgery. The psychosexual impact of the operation was beneficial in the majority of cases. Penile girth enlargement with acellular dermal matrix grafts has several advantages over augmentation with autogenous dermis-fat grafts: the elimination of donor site morbidity and a significantly shorter operation time. With this approach, through a short dorsal incision at the base of the penis, the scar is concealed in a crease covered by pubic hair and thus hardly visible. © 2012 International Society for Sexual Medicine.

  3. AccessScope project: Accessible light microscope for users with upper limb mobility or visual impairments.

    PubMed

    Mansoor, Awais; Ahmed, Wamiq M; Samarapungavan, Ala; Cirillo, John; Schwarte, David; Robinson, J Paul; Duerstock, Bradley S

    2010-01-01

    A web-based application was developed to remotely view slide specimens and control all functions of a research-level light microscopy workstation, called AccessScope. Students and scientists with upper limb mobility and visual impairments are often unable to use a light microscope by themselves and must depend on others in its operation. Users with upper limb mobility impairments and low vision were recruited to assist in the design process of the AccessScope personal computer (PC) user interface. Participants with these disabilities were evaluated in their ability to use AccessScope to perform microscopical tasks. AccessScope usage was compared with inspecting prescanned slide images by grading participants' identification and understanding of histological features and knowledge of microscope operation. With AccessScope subjects were able to independently perform common light microscopy functions through an Internet browser by employing different PC pointing devices or accessibility software according to individual abilities. Subjects answered more histology and microscope usage questions correctly after first participating in an AccessScope test session. AccessScope allowed users with upper limb or visual impairments to successfully perform light microscopy without assistance. This unprecedented capability is crucial for students and scientists with disabilities to perform laboratory coursework or microscope-based research and pursue science, technology, engineering, and mathematics fields.

  4. Magnification concepts: The use of video-probe microscopy to stimulate excitement and hands-on discovery in the science classroom K-12

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henk, C.; Garner, J.; Wandersee, J.H.

    1994-12-31

    We acquired and loaned several durable, easy-to use, though expensive video-probe microscopes. This hand-held, automatically focusing instrument can be used by a five year old and provides instant, excellent, in-focus images up to 200X on a video screen visible to all students simultaneously. The teacher is thus freed from the technical and logistic considerations involved in conventional classroom microscopy. K-12 teachers preview our videotape on probe utilization. They assemble and demonstrate the unit in the presence of our personnel, then check out the probe for use in their own classrooms. Extremely enthusiastic students examine samples ranging from their own fingerprintsmore » and clothing (on TV!) to pond water, prepared microscope slides, and microscope polarizing light phenomena. Teachers report heightened interest in conventional microscope use once the {open_quotes}microscopy connection{close_quotes} has been made.« less

  5. High field Nb/sub 3/Sn Axicell insert coils for the Mirror Fusion Test Facility-B (MFTF-B) axicell configuration. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baldi, R.W.; Tatro, R.E.; Scanlan, R.M.

    1984-03-01

    Two 12-tesla superconducting insert coils are being designed by General Dynamics Convair Division for the axicell regions of MFTF-B for Lawrence Livermore National Laboratory. A major challenge of this project is to ensure that combined fabrication and operational strains induced in the conductor are within stringent limitations of the relatively brittle Nb/sub 3/Sn superconductor filaments. These coils are located in the axicell region of MFTF-B. They have a clear-bore diameter of 36.195cm (14.25 inches) and consist of 27 double pancakes (i.e., 54 pancakes per coil) would on an electrically insulated 304LN stainless steel/bobbin helium vessel. Each pancake has 57 turnsmore » separated by G-10CR insulation. The complete winding bundle has 4.6 million ampere-turns and uniform current density of 2007 A/cm/sup 2/. In conjunction with the other magnets in the system, they produce a 12-tesla central field and a 12.52-tesla peak field. A multifilamentary Nb/sub 3/Sn conductor was selected to meet these requirements. The conductor consists of a monolithic insert soldered into a copper stabilizer. Sufficient cross-sectional area and work-hardening of the copper stabilizer has been provided for the conductor to self-react the electromagnetic Lorentz force induced hoop stresses with normal operational tensile strains less than 0.07 percent.« less

  6. Performance and durability of improved air-atomizing splash-cone fuel nozzles

    NASA Technical Reports Server (NTRS)

    Ingebo, R. D.; Norgren, C. T.

    1974-01-01

    An improved design of air-atomizing fuel nozzles was determined from a study of four differently shaped splash-cone fuel nozzles after 56 hr of durability testing in a combustor segment. Test conditions included fuel-air ratios of 0.008 to 0.018, inlet-air total pressures of 41 to 203 N/cm, inlet-air temperatures of 477 to 811 K, and a reference velocity of 21.3 m/sec. Flat-tip fuel nozzles showed the least erosion damage and at a combustor operating condition of 700 K and 101 N/sq cm an oxides-of-nitrogen emission index of 12 and a smoke number of approximately 18 with a fuel-air ratio of 0.018. Emission indices for carbon monoxide and unburned hydrocarbons were 44 and 16, respectively, at simulated idle conditions of 477 K and 41 N/sq cm.

  7. Performance of 10-kW class xenon ion thrusters

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.; Rawlin, Vincent K.

    1988-01-01

    Presented are performance data for laboratory and engineering model 30 cm-diameter ion thrusters operated with xenon propellant over a range of input power levels from approximately 2 to 20 kW. Also presented are preliminary performance results obtained from laboratory model 50 cm-diameter cusp- and divergent-field ion thrusters operating with both 30 cm- amd 50 cm-diameter ion optics up to a 20 kW input power. These data include values of discharge chamber propellant and power efficiencies, as well as values of specific impulse, thruster efficiency, thrust and power. The operation of the 30 cm- and 50 cm-diameter ion optics are also discussed.

  8. Cleaning of inner vacuum surfaces in the Uragan-3M facility by radio-frequency discharges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lozin, A. V., E-mail: alexlozin@meta.ua; Moiseenko, V. E.; Grigor’eva, L. I.

    2013-08-15

    A method for cleaning vacuum surfaces by a low-temperature (T{sub e} ∼ 10 eV) relatively dense (n{sub e} ≈ 10{sup 12} cm{sup −3}) plasma of an RF discharge was developed and successfully applied at the Uragan-3M torsatron. The convenience of the method is that it can be implemented with the same antenna system and RF generators that are used to produce and heat the plasma in the operating mode and does not require retuning the frequencies of the antennas and RF generators. The RF discharge has a high efficiency from the standpoint of cleaning vacuum surfaces. After performing a seriesmore » of cleanings by the low-temperature RF discharge plasma (about 20000 pulses), (i) the intensity of the CIII impurity line was substantially reduced, (ii) a quasi-steady operating mode with a duration of up to 50 ms, a plasma density of n{sub e} ≈ 10{sup 12} cm{sup −3}, and an electron temperature of up to T{sub e} ∼ 1 keV was achieved, and (iii) mass spectrometric analysis of the residual gas in the chamber indicated a significant reduction in the impurity content.« less

  9. Fusion enhancement at near and sub-barrier energies in 19O + 12C

    DOE PAGES

    Singh, Varinderjit; Vadas, J.; Steinbach, T. K.; ...

    2016-12-12

    Measuring the fusion excitation function for an isotopic chain of projectile nuclei provides a stringent test of a microscopic description of fusion. We report the first measurement of the fusion excitation function at near-barrier energies for the 19O+ 12C system. The measured excitation function is compared with the fusion excitation function of 18O+ 12C. A significant enhancement in the fusion probability of 19O ions with a 12C target as compared to 18O ions is observed. As a result, the experimental cross-sections observed at near-barrier energies are compared with a state-of-the-art microscopic model.

  10. Spectroscopy of reflection-asymmetric nuclei with relativistic energy density functionals

    NASA Astrophysics Data System (ADS)

    Xia, S. Y.; Tao, H.; Lu, Y.; Li, Z. P.; Nikšić, T.; Vretenar, D.

    2017-11-01

    Quadrupole and octupole deformation energy surfaces, low-energy excitation spectra, and transition rates in 14 isotopic chains: Xe, Ba, Ce, Nd, Sm, Gd, Rn, Ra, Th, U, Pu, Cm, Cf, and Fm, are systematically analyzed using a theoretical framework based on a quadrupole-octupole collective Hamiltonian (QOCH), with parameters determined by constrained reflection-asymmetric and axially symmetric relativistic mean-field calculations. The microscopic QOCH model based on the PC-PK1 energy density functional and δ -interaction pairing is shown to accurately describe the empirical trend of low-energy quadrupole and octupole collective states, and predicted spectroscopic properties are consistent with recent microscopic calculations based on both relativistic and nonrelativistic energy density functionals. Low-energy negative-parity bands, average octupole deformations, and transition rates show evidence for octupole collectivity in both mass regions, for which a microscopic mechanism is discussed in terms of evolution of single-nucleon orbitals with deformation.

  11. Aberration corrected 1.2-MV cold field-emission transmission electron microscope with a sub-50-pm resolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akashi, Tetsuya; Takahashi, Yoshio; Tanigaki, Toshiaki, E-mail: toshiaki.tanigaki.mv@hitachi.com

    2015-02-16

    Atomic-resolution electromagnetic field observation is critical to the development of advanced materials and to the unveiling of their fundamental physics. For this purpose, a spherical-aberration corrected 1.2-MV cold field-emission transmission electron microscope has been developed. The microscope has the following superior properties: stabilized accelerating voltage, minimized electrical and mechanical fluctuation, and coherent electron emission. These properties have enabled to obtain 43-pm information transfer. On the bases of these performances, a 43-pm resolution has been obtained by correcting lens aberrations up to the third order. Observations of GaN [411] thin crystal showed a projected atomic locations with a separation of 44 pm.

  12. A milliKelvin scanning Hall probe microscope for high resolution magnetic imaging

    NASA Astrophysics Data System (ADS)

    Khotkevych, V. V.; Bending, S. J.

    2009-02-01

    The design and performance of a novel scanning Hall probe microscope for milliKelvin magnetic imaging with submicron lateral resolution is presented. The microscope head is housed in the vacuum chamber of a commercial 3He-refrigerator and operates between room temperature and 300 mK in magnetic fields up to 10 T. Mapping of the local magnetic induction at the sample surface is performed by a micro-fabricated 2DEG Hall probe equipped with an integrated STM tip. The latter provides a reliable mechanism of surface tracking by sensing and controlling the tunnel currents. We discuss the results of tests of the system and illustrate its potential with images of suitable reference samples captured in different modes of operation.

  13. Effect of the angle of the operating microscope light beam on visual recovery after phacoemulsification: Randomized trial.

    PubMed

    Harman, Francesca E; Corbett, Melanie C; Stevens, Julian D

    2010-08-01

    To evaluate differences in visual recovery after phacoemulsification with direct or tilted surgical microscope illumination using a macular photostress test. Western Eye Hospital, Imperial College Health Care National Health Service Trust, London, United Kingdom. This randomized double-masked controlled trial enrolled patients presenting to a daycare unit for single-eye cataract surgery. Inclusion criteria were no ocular pathology other than cataract, corneal keratometric astigmatism less than 1.50 diopters, intended target of emmetropia in the operated eye, and cataract grade 1 to 3 (Lens Opacification Classification System II). Exclusion criteria were an abnormal preoperative photostress test. Patients were randomized to have phacoemulsification with the operating microscope angled 15 degrees nasal to the fovea (study group) or with the operating microscope directly overhead around the optic disc region (control group). The same surgeon performed all phacoemulsification procedures using a standardized technique and topical anesthesia. Outcome measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuity 10 minutes and 60 minutes postoperatively. In the 30 patients evaluated, the mean UDVA 10 minutes postoperatively was 0.40 logMAR +/- 0.26 (SD) in the study group and 0.72 +/- 0.36 logMAR in the control group (P<.01). The mean CDVA was 0.18 +/- 0.26 logMAR and 0.44 +/- 0.30 logMAR, respectively (P = .016). There was no significant between-group difference in acuity at 60 minutes. Tilting the microscope beam away from the fovea resulted in faster visual recovery and less macular photic stress. No author has a financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Quality of life and complications at the different stages of bone transport for treatment infected nonunion of the tibia.

    PubMed

    Wang, Hu; Wei, Xing; Liu, Ping; Fu, Ya-Hui; Wang, Peng-Fei; Cong, Yu-Xuan; Zhang, Bin-Fei; Li, Zhong; Lei, Jin-Lai; Zhang, Kun; Zhuang, Yan

    2017-11-01

    The aim of this study was to assess Physical Component Summary (PCS), Mental Component Summary (MCS) of the Mos 36-item Short Form Health Survey (SF-36) score, and the virtual Analogue Scale (VAS) of pain during the treatment period and the complication rate associated with infected nonunion of the tibia managed surgically by bone transport.This is a retrospective analysis of prospectively collected data in a consecutive patient cohort. Patients suffering from infected nonunion of the tibia were treated by bone transport from 2012 to 2014. Follow-up was for at least 2 years after complete osseous consolidation. Standardized treatment included bacterial eradication by segmental resection, bone transport using Ilizarov apparatus, and docking maneuver. The main outcome measurements consisted of the quality of life (PCS and MCS scores) and the VAS of pain during the different stages of therapy. In addition, all complications were documented.Our series comprised 12 men and 3 women with an average age of 36.9 years (range: 20-55 years). All patients previously undergone an average of 2.9 operations (range: 1-6 operations). In all patients, bone defects were present with a mean size of 7.5 cm (range: 3-12 cm), and all patients were suffering from soft tissue defects (range: 5-17 cm). The mean external fixator time (EFT) was 48 weeks (range: 30-62 weeks) and the mean external fixation index was 43.1 days/cm (range: 33-62 days/cm). All patients achieved bone union, and no recurrence of infection was observed. According to the Paley classification, patients suffered 15 minor and 13 major complications. The average complication rate per patient comprised of 1.0 minor and 0.9 major complications. Bone grafting was required in 6 cases at the docking site. One patient suffered from equinus deformity, and refused any further surgical procedures. We performed 28 operations in 15 patients (average 1.9 operations per patient). After the period of bone transport, PCS and MCS scores increased continuously. After completed consolidation, the average MCS score was comparable to a normal collective, and the average VAS score was 1.87 (range: 0-3).Bone transport is a safe option for the treatment of infected nonunion of the tibia despite the high complication rate. The arduous and demanding nature of this treatment subjects patient to considerable the pain, mental, and physical stress. The average VAS scores, PCS, and MCS scores significantly improve at final follow-up. It is essential to communicate this fact to the patients and their relatives before the application of the frame in order to increase their compliance with the long and emotionally draining treatment.

  15. Theory of a Quantum Scanning Microscope for Cold Atoms

    NASA Astrophysics Data System (ADS)

    Yang, D.; Laflamme, C.; Vasilyev, D. V.; Baranov, M. A.; Zoller, P.

    2018-03-01

    We propose and analyze a scanning microscope to monitor "live" the quantum dynamics of cold atoms in a cavity QED setup. The microscope measures the atomic density with subwavelength resolution via dispersive couplings to a cavity and homodyne detection within the framework of continuous measurement theory. We analyze two modes of operation. First, for a fixed focal point the microscope records the wave packet dynamics of atoms with time resolution set by the cavity lifetime. Second, a spatial scan of the microscope acts to map out the spatial density of stationary quantum states. Remarkably, in the latter case, for a good cavity limit, the microscope becomes an effective quantum nondemolition device, such that the spatial distribution of motional eigenstates can be measured backaction free in single scans, as an emergent quantum nondemolition measurement.

  16. Theory of a Quantum Scanning Microscope for Cold Atoms.

    PubMed

    Yang, D; Laflamme, C; Vasilyev, D V; Baranov, M A; Zoller, P

    2018-03-30

    We propose and analyze a scanning microscope to monitor "live" the quantum dynamics of cold atoms in a cavity QED setup. The microscope measures the atomic density with subwavelength resolution via dispersive couplings to a cavity and homodyne detection within the framework of continuous measurement theory. We analyze two modes of operation. First, for a fixed focal point the microscope records the wave packet dynamics of atoms with time resolution set by the cavity lifetime. Second, a spatial scan of the microscope acts to map out the spatial density of stationary quantum states. Remarkably, in the latter case, for a good cavity limit, the microscope becomes an effective quantum nondemolition device, such that the spatial distribution of motional eigenstates can be measured backaction free in single scans, as an emergent quantum nondemolition measurement.

  17. Virtual microscopes in podiatric medical education.

    PubMed

    Becker, John H

    2006-01-01

    In many medical schools, microscopes are being replaced as teaching tools by computers with software that emulates the use of a light microscope. This article chronicles the adoption of "virtual microscopes" by a podiatric medical school and presents the results of educational research on the effectiveness of this adoption in a histology course. If the trend toward virtual microscopy in education continues, many 21st-century physicians will not be trained to operate a light microscope. The replacement of old technologies by new is discussed. The fundamental question is whether all podiatric physicians should be trained in the use of a particular tool or only those who are likely to use it in their own practice.

  18. Operating characteristics of tube-current-modulation techniques when scanning simple-shaped phantoms

    NASA Astrophysics Data System (ADS)

    Matsubara, Kosuke; Koshida, Kichiro; Lin, Pei-Jan Paul; Fukuda, Atsushi

    2015-07-01

    Our objective was to investigate the operating characteristics of tube current modulation (TCM) in computed tomography (CT) when scanning two types of simple-shaped phantoms. A tissueequivalent elliptical phantom and a homogeneous cylindrical step phantom comprising 16-, 24-, and 32-cm-diameter polymethyl methacrylate (PMMA) phantoms were scanned by using an automatic exposure control system with longitudinal (z-) and angular-longitudinal (xyz-) TCM and with a fixed tube current. The axial dose distribution throughout the elliptical phantom and the longitudinal dose distribution at the center of the cylindrical step phantom were measured by using a solid-state detector. Image noise was quantitatively measured at eight regions in the elliptical phantom and at 90 central regions in contiguous images over the full z extent of the cylindrical step phantom. The mean absorbed doses and the standard deviations in the elliptical phantom with z- and xyz-TCM were 12.3' 3.7 and 11.3' 3.5 mGy, respectively. When TCM was activated, some differences were observed in the absorbed doses of the left and the right measurement points. The average image noises in Hounsfield units (HU) and the standard deviations were 15.2' 2.4 and 15.9' 2.4 HU when using z- and xyz-TCM, respectively. With respect to the cylindrical step phantom under z-TCM, there were sudden decreases followed by increases in image noise at the interfaces with the 24- and 16-cm-diameter phantoms. The image noise of the 24-cm-diameter phantom was, relatively speaking, higher than those of the 16- and 32-cm-diameter phantoms. The simple-shaped phantoms used in this study can be employed to investigate the operating characteristics of automatic exposure control systems when specialized phantoms designed for that purpose are not available.

  19. TH-CD-201-07: Experimentally Investigating Proton Energy Deposition On the Microscopic Scale Using Fluorescence Nuclear Track Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Underwood, T; University College London, London; McFadden, C

    Purpose: In order to further understand the interplay between proton physics and radiobiology it is necessary to consider proton energy deposition on the microscopic scale. In this work we used Fluorescent Nuclear Track Detectors (FNTDs) to experimentally investigate proton energy deposition, track-by-track. Methods: We irradiated 8×4×0.5mm{sup 3} FNTD chips (Landauer Inc) at seven water depths along a pristine proton Bragg peak with range=12cm. After irradiation, the FNTDs were scanned using a confocal microscope (FV1200, Olympus) with a high-power red laser and an oil-immersion objective lens (UPLSAPO60XO, NA=1.35). 10 slice image stacks were acquired with a slice-thickness of 2µm at multiplemore » positions across each FNTD. Image-based analyses of track radius and track “mass” (integrated signal intensity) were performed using trackpy. For comparison, Monte Carlo simulated data were obtained using TOPAS and TOPAS-nBio. Results: Excellent correlation was observed between median track mass and TOPAS dose-averaged linear energy transfer. The resolution of the imaging system was determined insufficient to detect a relationship between track radius and exposure depth. Histograms of track mass (i) displayed strong repeatability across positions within an FNTD and (ii) varied in peak position and shape as a function of depth. TOPAS-nBio simulations implemented on the nanometer scale using physics lists from GEANT4-DNA yielded energy deposition distributions for individual protons and electrons scored within a virtual FNTD. Good agreement was found between these simulated datasets and the FNTD track mass distributions. Conclusion: Robust experimental measurements of the integral energy deposited by individual proton tracks can be performed using FNTDs. Monte Carlo simulations offer an exceedingly powerful approach to the quantification of proton energy deposition on the microscopic scale, but whilst they have been well validated at the macroscopic level, their microscopic validation is far from complete. Our results demonstrate that FNTD-based study can play an important role in addressing this deficit. Tracy Underwood gratefully acknowledges the support of the European Commission under an FP7 Marie Curie International Outgoing Fellowship for Career Development (#630064).« less

  20. Effect of controlling recrystallization from the melt on the residual stress and structural properties of the Silica-clad Ge core fiber

    NASA Astrophysics Data System (ADS)

    Zhao, Ziwen; Cheng, Xueli; He, Ting; Xue, Fei; Zhang, Wei; Chen, Na; Wen, Jianxiang; Zeng, Xianglong; Wang, Tingyun

    2017-09-01

    Effect of controlling recrystallization from the melt (1000 °C) on the residual stress and structural properties of a Ge core fiber via molten core drawing (MCD) method is investigated. Ge core fibers is investigated using Raman spectroscopy, scanning electron microscope (SEM), and X-ray diffraction (XRD). Compared with the as-drawn Ge fiber, the Raman peak of the recrystallized Ge fiber shift from 300 cm-1 to 300.6 cm-1 and full width at half maximum (FWHM) decreased from 5.36 cm-1 to 4.48 cm-1. The Ge crystal grains which sizes are of 200-600 nm were formed during the process of recrystallization; the XRD peak of (1 1 1) plane is observed after recrystallization. These results show that controlling recrystallization allows the release of the thermal stress, and improvement of the crystal quality of Ge core.

  1. One-step synthesis of hybrid inorganic-organic nanocomposite coatings by novel laser adaptive ablation deposition technique

    NASA Astrophysics Data System (ADS)

    Serbezov, Valery; Sotirov, Sotir

    2013-03-01

    A novel approach for one-step synthesis of hybrid inorganic-organic nanocomposite coatings by new modification of Pulsed Laser Deposition technology called Laser Adaptive Ablation Deposition (LAAD) is presented. Hybrid nanocomposite coatings including Mg- Rapamycin and Mg- Desoximetasone were produced by UV TEA N2 laser under low vacuum (0.1 Pa) and room temperature onto substrates from SS 316L, KCl and NaCl. The laser fluence for Mg alloy was 1, 8 J/cm2 and for Desoximetasone 0,176 J/cm2 and for Rapamycin 0,118 J/cm2 were respectively. The threedimensional two-segmented single target was used to adapt the interaction of focused laser beam with inorganic and organic material. Magnesium alloy nanoparticles with sizes from 50 nm to 250 nm were obtained in organic matrices. The morphology of nanocomposites films were studied by Bright field / Fluorescence optical microscope and Scanning Electron Microscope (SEM). Fourier Transform Infrared (FTIR) spectroscopy measurements were applied in order to study the functional properties of organic component before and after the LAAD process. Energy Dispersive X-ray Spectroscopy (EDX) was used for identification of Mg alloy presence in hybrid nanocomposites coatings. The precise control of process parameters and particularly of the laser fluence adjustment enables transfer on materials with different physical chemical properties and one-step synthesis of complex inorganic- organic nanocomposites coatings.

  2. SERS Detection of Dopamine Using Label-Free Acridine Red as Molecular Probe in Reduced Graphene Oxide/Silver Nanotriangle Sol Substrate

    NASA Astrophysics Data System (ADS)

    Luo, Yanghe; Ma, Lu; Zhang, Xinghui; Liang, Aihui; Jiang, Zhiliang

    2015-05-01

    The reduced graphene oxide/silver nanotriangle (rGO/AgNT) composite sol was prepared by the reduction of silver ions with sodium borohydride in the presence of H2O2 and sodium citrate. In the nanosol substrate, the molecular probe of acridine red (AR) exhibited a weak surface-enhanced Raman scattering (SERS) peak at 1506 cm-1 due to its interaction with the rGO of rGO/AgNT. Upon addition of dopamine (DA), the competitive adsorption between DA and AR with the rGO took place, and the AR molecules were adsorbed on the AgNT aggregates with a strong SERS peak at 1506 cm-1 that caused the SERS peak increase. The increased SERS intensity is linear to the DA concentration in the range of 2.5-500 μmol/L. This new analytical system was investigated by SERS, fluorescence, absorption, transmission electron microscope (TEM), and scanning electron microscope (SEM) techniques, and a SERS quantitative analysis method for DA was established, using AR as a label-free molecular probe.

  3. Surface topographical and structural analysis of Ag+-implanted polymethylmethacrylate

    NASA Astrophysics Data System (ADS)

    Arif, Shafaq; Rafique, M. Shahid; Saleemi, Farhat; Naab, Fabian; Toader, Ovidiu; Sagheer, Riffat; Bashir, Shazia; Zia, Rehana; Siraj, Khurram; Iqbal, Saman

    2016-08-01

    Specimens of polymethylmethacrylate (PMMA) were implanted with 400-keV Ag+ ions at different ion fluences ranging from 1 × 1014 to 5 × 1015 ions/cm2 using a 400-kV NEC ion implanter. The surface topographical features of the implanted PMMA were investigated by a confocal microscope. Modifications in the structural properties of the implanted specimens were analyzed in comparison with pristine PMMA by X-ray diffraction (XRD) and Raman spectroscopy. UV-Visible spectroscopy was applied to determine the effects of ion implantation on optical transmittance of the implanted PMMA. The confocal microscopic images revealed the formation of hillock-like microstructures along the ion track on the implanted PMMA surface. The increase in ion fluence led to more nucleation of hillocks. The XRD pattern confirmed the amorphous nature of pristine and implanted PMMA, while the Raman studies justified the transformation of Ag+-implanted PMMA into amorphous carbon at the ion fluence of ⩾5 × 1014 ions/cm2. Moreover, the decrease in optical transmittance of PMMA is associated with the formation of hillocks and ion-induced structural modifications after implantation.

  4. Nanoscale infrared (IR) spectroscopy and imaging of structural lipids in human stratum corneum using an atomic force microscope to directly detect absorbed light from a tunable IR laser source.

    PubMed

    Marcott, Curtis; Lo, Michael; Kjoller, Kevin; Domanov, Yegor; Balooch, Guive; Luengo, Gustavo S

    2013-06-01

    An atomic force microscope (AFM) and a tunable infrared (IR) laser source have been combined in a single instrument (AFM-IR) capable of producing ~200-nm spatial resolution IR spectra and absorption images. This new capability enables IR spectroscopic characterization of human stratum corneum at unprecendented levels. Samples of normal and delipidized stratum corneum were embedded, cross-sectioned and mounted on ZnSe prisms. A pulsed tunable IR laser source produces thermomechanical expansion upon absorption, which is detected through excitation of contact resonance modes in the AFM cantilever. In addition to reducing the total lipid content, the delipidization process damages the stratum corneum morphological structure. The delipidized stratum corneum shows substantially less long-chain CH2 -stretching IR absorption band intensity than normal skin. AFM-IR images that compare absorbances at 2930/cm (lipid) and 3290/cm (keratin) suggest that regions of higher lipid concentration are located at the perimeter of corneocytes in the normal stratum corneum. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Epi-detected quadruple-modal nonlinear optical microscopy for label-free imaging of the tooth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zi; Zheng, Wei; Huang, Zhiwei, E-mail: biehzw@nus.edu.sg

    2015-01-19

    We present an epi-detected quadruple-modal nonlinear optical microscopic imaging technique (i.e., coherent anti-Stokes Raman scattering (CARS), second-harmonic generation (SHG), third-harmonic generation (THG), and two-photon excited fluorescence (TPEF)) based on a picosecond (ps) laser-pumped optical parametric oscillator system for label-free imaging of the tooth. We demonstrate that high contrast ps-CARS images covering both the fingerprint (500–1800 cm{sup −1}) and high-wavenumber (2500–3800 cm{sup −1}) regions can be acquired to uncover the distributions of mineral and organic biomaterials in the tooth, while high quality TPEF, SHG, and THG images of the tooth can also be acquired under ps laser excitation without damaging the samples. Themore » quadruple-modal nonlinear microscopic images (CARS/SHG/THG/TPEF) acquired provide better understanding of morphological structures and biochemical/biomolecular distributions in the dentin, enamel, and the dentin-enamel junction of the tooth without labeling, facilitating optical diagnosis and characterization of the tooth in dentistry.« less

  6. [APPLICATION VALUE OF INDOCYANINE GREEN ANGIOGRAPHY IN FLAP RECONSTRUCTIVE SURGERY].

    PubMed

    Yang, Kai; Mu, Lan; Liu, Yan; Peng, Zhe; Li, Guangxue

    2015-09-01

    To investigate the utility of indocyanine green angiography in flap reconstructive surgery and possibility of decrease the complications. Indocyanine green angiography was performed on 14 patients undergoing flap reconstructive surgery between February and December 2014 to evaluate the blood perfusion of the flap and to adjust the operation plan. Of 14 cases, 2 were male and 12 were female, aged 23-58 years (mean, 35.5 years); 11 flaps were used for breast reconstruction [including 3 free deep inferior epigastric antery perforator (DIEP) flaps, 4 pedicled transverse rectus abdominis myocutaneous flaps (TRAM), 2 pedicled TRAM and free TRAM, and 2 pedicled latissimus dorsi myocutaneous flaps and prosthesis], 1 pedicled latissimus dorsi myocutaneous flap for repairing chest wall defect, 1 pedicled profunda artery perforator (PAP) flap for upper leg defect, and 1 pedicled descending genicular artery perforator flap for knee defect. The size of the flaps ranged from 9 cm x 6 cm to 26 cm x 12 cm. A total of 32 indocyanine green angiography were performed. There was no adverse reactions to the infusion of indocyanine green. The surgery management was adjusted according to results of indocyanine green angiography findings in 5 of 14 cases. The distal part of flap were discarded because of poor perfusion in 3 cases (1 DIEP flap, 1 TRAM, and 1 PAP flap) and the other 2 cases (pedicled TRAM) needed additional free anastomosis to ensure sufficient blood supply (pedicled TRAM and free TRAM); the other flaps were harvested according to preoperative plan and repaired defect successfully. The mean follow-up was 5 months (range, 1-9 months). The other flaps survived without infection or fat necrosis except 1 PAP flap with distal necrosis. Intraoperative indocyanine green angiography can provide real-time information of flap perfusion and then the operation plan can be adjusted in time to ensure the flap survival.

  7. Development of Low-Cost Inverted Microscope to Detect Early Growth of Mycobacterium tuberculosis in MODS Culture

    PubMed Central

    Zimic, Mirko; Velazco, Abner; Comina, Germán; Coronel, Jorge; Fuentes, Patricia; Luna, Carmen G.; Sheen, Patricia; Gilman, Robert H.; Moore, David A. J.

    2010-01-01

    Background The microscopic observation drug susceptibility (MODS) assay for rapid, low-cost detection of tuberculosis and multidrug resistant tuberculosis depends upon visualization of the characteristic cording colonies of Mycobacterium tuberculosis in liquid media. This has conventionally required an inverted light microscope in order to inspect the MODS culture plates from below. Few tuberculosis laboratories have this item and the capital cost of $5,000 for a high-end microscope could be a significant obstacle to MODS roll-out. Methodology We hypothesized that the precise definition provided by costly high-specification inverted light microscopes might not be necessary for pattern recognition. Significance In this work we describe the development of a low-cost artesenal inverted microscope that can operate in both a standard or digital mode to effectively replace the expensive commercial inverted light microscope, and an integrated system that could permit a local and remote diagnosis of tuberculosis. PMID:20351778

  8. Impact of Microscope-Integrated OCT on Ophthalmology Resident Performance of Anterior Segment Surgical Maneuvers in Model Eyes

    PubMed Central

    Todorich, Bozho; Shieh, Christine; DeSouza, Philip J.; Carrasco-Zevallos, Oscar M.; Cunefare, David L.; Stinnett, Sandra S.; Izatt, Joseph A.; Farsiu, Sina; Mruthyunjaya, Privthi; Kuo, Anthony N.; Toth, Cynthia A.

    2016-01-01

    Purpose The integration of swept-source optical coherence tomography (SS-OCT) into the operating microscope enables real-time, tissue-level three-dimensional (3D) imaging to aid in ophthalmic microsurgery. In this prospective randomized controlled study, we evaluated the impact of SS microscope-integrated OCT (MI-OCT) on ophthalmology residents' performance of ophthalmic microsurgical maneuvers. Methods Fourteen ophthalmology residents from a single institution were stratified by year of training and randomized to perform four anterior segment surgical maneuvers on porcine eyes with (MI-OCT+) or without (MI-OCT−) direct intraoperative OCT guidance. Subsequently, both groups repeated the same maneuvers without MI-OCT feedback to test whether initial MI-OCT experience affected subsequent surgical performance. Finally, the MI-OCT− group was crossed over and allowed to repeat the same maneuvers with direct MI-OCT guidance. Each resident completed a survey at the completion of the study. Results With direct MI-OCT feedback, residents demonstrated enhanced performance in depth-based anterior segment maneuvers (corneal suture passes at 50% and 90% depth and corneal laceration repair) compared with the residents operating without MI-OCT. Microscope-integrated OCT+ residents continued to outperform the controls when both groups subsequently operated without MI-OCT. For clear corneal wound geometry, there was no statistically significant effect of MI-OCT as applied in this study. Overall, the resident surgeons rated their subjective experience of using MI-OCT very favorably. Conclusions Microscope-integrated OCT feedback enhances performance of ophthalmology residents in select anterior segment surgical maneuvers. Microscope-integrated OCT represents a valuable tool in the surgical education of ophthalmology residents. PMID:27409466

  9. Hot ion plasma production in HIP-1 using water-cooled hollow cathodes

    NASA Technical Reports Server (NTRS)

    Reinmann, J. J.; Lauver, M. R.; Patch, R. W.; Layman, R. W.; Snyder, A.

    1975-01-01

    The paper reports on hot-ion plasma experiments conducted in a magnetic mirror facility. A steady-state E x B plasma was formed by applying a strong radially inward dc electric field near the mirror throats. Most of the results were for hydrogen, but deuterium and helium plasmas were also studied. Three water-cooled hollow cathodes were operated in the hot-ion plasma mode with the following results: (1) thermally emitting cathodes were not required to achieve the hot-ion mode; (2) steady-state operation (several minutes) was attained; (3) input powers greater than 40 kW were achieved; (4) cathode outside diameters were increased from 1.2 cm (uncooled) to 4.4 cm (water-cooled); (5) steady-state hydrogen plasmas with ion temperatures from 185 to 770 eV and electron temperatures from 5 to 21 eV were produced. Scaling relations were empirically obtained for discharge current, ion temperature, electron temperature, and relative ion density as a function of hydrogen gas feed rate, magnetic field, and cathode voltage.

  10. Use of a Fourier transform spectrometer on a balloon-borne telescope and at the multiple mirror telescope (MMT)

    NASA Technical Reports Server (NTRS)

    Traub, W. A.; Chance, K. V.; Brasunas, J. C.; Vrtilek, J. M.; Carleton, N. P.

    1982-01-01

    The design and use of an infrared Fourier transform spectrometer which has been used for observations of laboratory, stratospheric, and astronomical spectra are described. The spectrometer has a spectral resolution of 0.032/cm and has operated in the mid-infrared (12 to 13 microns) as well as the far-infrared (40 to 140 microns), using both bolometer and photoconductor cryogenic detectors. The spectrometer is optically sized to accept an f/9 beam from the multi-mirror telescope (MMT). The optical and electronic design are discussed, including remote operation of the spectrometer on a balloon-borne 102-cm telescope. The performance of the laser-controlled, screw-driven moving cat's-eye mirror is discussed. Segments of typical far-infrared balloon flight spectra, lab spectra, and mid-infrared MMT spectra are presented. Data reduction, interferogram processing, artifact removal, wavelength calibration, and intensity calibration methods are discussed. Future use of the spectrometer is outlined.

  11. Microscope-aided endodontic treatment of maxillary first premolars with three roots: a case series.

    PubMed

    Karumaran, C S; Gunaseelan, R; Krithikadatta, J

    2011-01-01

    Maxillary premolars have a highly variable root canal morphology. However, the presence of three roots is a rare occurrence. This clinical article describes the unusual anatomy detected in maxillary premolars during routine endodontic treatment using microscope. The diagnosis and clinical management of maxillary first premolars with three roots and canals using radiographic interpretation, access cavity modification and visual enhancement with operative microscopes is discussed in the article.

  12. 16 CFR 500.28 - Variety packages.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... other terms used. Examples: (i) “2 sponges 41/2 ins. × 4 ins. ×3/4 in. (11.4 cm × 10.1 cm × 1.9 cm); 1 sponge 41/2 ins. × 8 ins. ×3/4 in. (11.4 cm × 20.3 cm × 1.9 cm); 4 sponges 21/2 ins. × 4 ins. ×1/2 in. (6.3 cm × 10.1 cm × 1.2 cm) Total: 7 sponges”. (ii) “2 soap bars Net Wt. 3.2 ozs. (90 g) each; 1 soap...

  13. A Study on Field Emission Characteristics of Planar Graphene Layers Obtained from a Highly Oriented Pyrolyzed Graphite Block

    PubMed Central

    2009-01-01

    This paper describes an experimental study on field emission characteristics of individual graphene layers for vacuum nanoelectronics. Graphene layers were prepared by mechanical exfoliation from a highly oriented pyrolyzed graphite block and placed on an insulating substrate, with the resulting field emission behavior investigated using a nanomanipulator operating inside a scanning electron microscope. A pair of tungsten tips controlled by the nanomanipulator enabled electric connection with the graphene layers without postfabrication. The maximum emitted current from the graphene layers was 170 nA and the turn-on voltage was 12.1 V. PMID:20596315

  14. Synthesis and Characterization Materials M-Barium Hexaferrite Doping Ions Co-Mn Nano Particle

    NASA Astrophysics Data System (ADS)

    Susilawati; Doyan, A.; Sahlam

    2017-05-01

    This research has been success in the synthesis of M-Barium hexaferrite (BaM) doping Co-Mn ions using coprecipitation method are expected to be applied as a base material in the coating RADAR. M-Barium hexaferrite (BaM) are BaFe12-2xCoxMnxO19 synthesized with various concentrations (x = 0.0, 0.1, 0.2, 0.3) and the calcinations temperature (T = 400°C, 600°C, 800°C). The materials characterization using a X-Ray Diffraction (XRD), Transmission Electron Microscope (TEM), Inductance Capacitance and resistance (LCR) meter, and Vibrating Sample Magnetometer (VSM) Instruments. The measurement results using XRD shows the material has a hexagonal crystalline structure. The measurement results using a TEM show a sample of nano crystal materials with grain diameters up to 40 nm and spacing of the crystal lattice. The measurement results using a LCR-meter shows the electric conductivity of 1.15 × 10-6 S/cm to BaM without doping, 3.75 × 10-6 S/cm to 0.1 doping concentration calcination temperature of 400 °C, and 1,23 × 10-5 S/cm to 0.3 doping concentration calcination temperature of 800 °C, thus including semiconductor materials. The magnetic properties of materials using a VSM test results show the value of coercivity of 0.1 T; remanence value of 0.06 emu/g; and the saturation value of 0.42 emu/g. The results above show BaM Co-Mn metal doping potential as anti-radar material.

  15. Explicit correlation treatment of the six-dimensional potential energy surface and predicted infrared spectra for OCS-H2

    NASA Astrophysics Data System (ADS)

    Liu, Jing-Min; Zhai, Yu; Li, Hui

    2017-07-01

    An effective six-dimensional ab initio potential energy surface (PES) for H2-OCS which explicitly includes the intramolecular stretch normal modes of carbonyl sulfide (OCS) is presented. The electronic structure computations are carried out using the explicitly correlated coupled cluster [CCSD(T)-F12] method with the augmented correlation-consistent aug-cc-pVTZ basis set, and the accuracy is critically tested by performing a series of benchmark calculations. Analytic four-dimensional PESs are obtained by least-squares fitting vibrationally averaged interaction energies to the Morse/long-range potential model. These fits to 13 485 points have a root-mean-square deviation (RMSD) of 0.16 cm-1. The combined radial discrete variable representation/angular finite basis representation method and the Lanczos algorithm were employed to evaluate the rovibrational energy levels for five isotopic species of the OCS-hydrogen complexes. The predicted transition frequencies and intensities based on the resulting vibrationally averaged PESs are in good agreement with the available experimental values, whose RMSDs are smaller than 0.004 cm-1 for five different species of OCS-hydrogen complexes. The calculated infrared band origin shifts for all five species of OCS-hydrogen complexes are only 0.03 cm-1 smaller than the corresponding experimental values. These validate the high quality of our PESs which can be used for modeling OCS doped in hydrogen clusters to further study quantum solution and microscopic superfluidity. In addition, the analytic coordinate transformation functions between isotopologues are also derived due to the center of mass shifting of different isotope substitutes.

  16. Study of thermal-field emission properties and investigation of temperature dependent noise in the field emission current from vertical carbon nanotube emitters

    NASA Astrophysics Data System (ADS)

    Kolekar, Sadhu; Patole, S. P.; Patil, Sumati; Yoo, J. B.; Dharmadhikari, C. V.

    2017-10-01

    We have investigated temperature dependent field electron emission characteristics of vertical carbon nanotubes (CNTs). The generalized expression for electron emission from well-defined cathode surface is given by Millikan and Lauritsen [1] for the combination of temperature and electric field effect. The same expression has been used to explain the electron emission characteristics from vertical CNT emitters. Furthermore, this has been applied to explain the electron emission for different temperatures ranging from room temperature to 1500 K. The real-time field electron emission images at room temperature and 1500 K are recorded by using Charge Coupled Device (CCD) in order to understand the effect of temperature on distribution of electron emission spots and ring like structures in Field Emission Microscope (FEM) image. The FEM images could be used to calculate the total number of emitters per cm2 for electron emission. The calculated number of emitters per cm2 from FEM image is typically, 4.5 × 107 and the actual number emitters per cm2 present as per Atomic Force Microscopy (AFM) data is 1.2 × 1012. The measured Current-Voltage (I-V) characteristics exhibit non linear Folwer-Nordheim (F-N) type behavior. The fluctuations in the emission current were recorded at different temperatures and Fast Fourier transformed into temperature dependent power spectral density. The latter was found to obey power law relation S(f) = A(Iδ/fξ), where δ and ξ are temperature dependent current and frequency exponents respectively.

  17. Possible Fengyun-1C debris fall

    NASA Astrophysics Data System (ADS)

    Golebiewska, J.; Nowak, M.; Muszyński, A.; Wnuk, E.

    2017-05-01

    A fall of small objects took place on 27th April 2012 in Wargowo village near Oborniki, about 25 km NW from Poznań (Poland). There was only one eye-witness of the fall, who found two separate pieces (ca. 2.7 cm and ca. 2 cm), with several small additional fragments. After microscopic observations and chemical analysis a meteoritic origin of these objects was excluded. They are identified as space debris, therefore man-made. The most probable source of the observed fall was space debris 35127 Fengyun 1C DEB, created during destruction of the Chinese weather satellite Fengyun-1C (FY-1C).

  18. Performance of La 0.75Sr 0.25Cr 0.5Mn 0.5O 3- δ perovskite-structure anode material at lanthanum gallate electrolyte for IT-SOFC running on ethanol fuel

    NASA Astrophysics Data System (ADS)

    Huang, Bo; Wang, S. R.; Liu, R. Z.; Ye, X. F.; Nie, H. W.; Sun, X. F.; Wen, T. L.

    Perovskite-structure La 0.75Sr 0.25Cr 0.5Mn 0.5O 3- δ (LSCM) powders were prepared using a simple combustion process. Thermal analysis was carried out on the perovskite precursor to investigate the oxide-phase formation. The structural phase of the powders was determined by X-ray diffraction. These results showed that the decomposition of the precursors occurs in a two-step reaction and temperatures higher than 1100 °C are required for these decomposition reactions. For the electrochemical characterization, LSCM anode materials and (Pr 0.7Ca 0.3) 0.9MnO 3 (PCM) cathode materials were screen-printed on two sides of dense La 0.8Sr 0.2Ga 0.8Mg 0.2O 3 (LSGM) electrolyte layers prepared by tape casting with a thickness of about 600 μm, respectively. The morphology of the screen-printed La 0.75Sr 0.25Cr 0.5Mn 0.5O 3- δ perovskite thick films (65 μm) was investigated by field emission scanning electron microscope and showed a porous microstructure. In addition, fuel cell tests were carried out using humidified hydrogen or ethanol stream as fuel and oxygen as oxidant. The performance of the conventional electrolyte-supported cell LSCM/LSGM/PCM while operating on humidified hydrogen was modest with a maximum power density of 165, 99 and 62 mW cm -2 at 850, 800 and 750 °C, respectively, the corresponding values for the cell while operating on ethanol stream was 160, 101 and 58 mW cm -2, respectively. Cell stability tests indicate no significant degradation in performance has been observed after 60 h of cell testing when LSCM anode was exposed to ethanol steam at 750 °C, suggesting that carbon deposition was limited during cell operation.

  19. Collision-Induced Spectra: AN Avenue to Investigate Microscopic-Scale Diffusion in Fluids

    NASA Astrophysics Data System (ADS)

    Herrebout, Wouter A.; van der Veken, Benjamin J.; Kouzov, Alexander

    2014-06-01

    New data on the IR spectra induced by intermolecular interactions in liquid cryogenic mixtures at T=89 K (O2 in LAr and LN2 and binary O2-Ar solutions in LN2) are reported. The induced fundamental bands appear as diffuse pedestals (with FWHH≈100 cm-1) on which weak, paradoxically sharp lines (FWHH≈2 cm-1) develop at the 2326 and 1552 cm-1 frequencies of the free-molecule vibrational transitions in N2 and O2, respectively. In LAr and LN2 these lines were carefully separated and studied at varied O2 concentrations up to c=0.23 mole fractions (mf). While the 1552 cm-1 line scales as c[O2]2 and thus is induced by the O2-O2 interactions in a bulk of cryosolvent (Ar, N2), the 2326 cm-1 feature varies linearly with c[O2] and hence is caused by interaction of a guest (O2) with a vibrating host (N_2). The impurity induction mechanism was further supported by our data on the binary O2-Ar solutions in LN2 %for which the spectra were recorded at the fixed c[O2] (0.03 and 0.06 mf) and the varied c% [Ar]≤0.2 mf. Both series revealed the same (linear) enhancement of the sharp N2 line by argon, in an accord with our previous studies of the Ar-LN2 system. The results suggest that the resonance 2326 cm-1 feature is primarily due to the local distortion of the first coordination sphere around a vibrating N_2 by a guest molecule. We also notice that the resonance lines should be due to the dispersion- and overlap-induced dipole moments independent on the rotational degrees of freedom. As our previous studies of the H2-LNe system showed, the unusual line sharpness is a conspicuous manifestation of the relative solvent-solute and solute-solute translations dramatically retarded in a liquid by a fast velocity relaxation, an effect directly related to the microscopic-scale diffusion. The collision-induced spectra thus open up new vistas for studies of microscopic liquid dynamics. W.A. Herrebout, A.A. Stolov, E.J. Sluyts, and B.J. van der Veken, Chem. Phys. Lett. 295, 223 (1998) J.E. Bohr and K.L.C. Hunt, J. Chem. Phys. 86, 5441 (1987) W. A. Herrebout, B. J. van der Veken, and A. P. Kouzov, Phys.Rev. Lett. 101, 093001 (2008) W. A. Herrebout, B. J. van der Veken, and A. P. Kouzov, J. Chem. Phys. 137, 084509 (2012)

  20. Extended Asymmetrical Pedicle Subtraction Osteotomy for Adult Spinal Deformity: 2-Dimensional Operative Video.

    PubMed

    Buell, Thomas J; Buchholz, Avery L; Quinn, John C; Mullin, Jeffrey P; Garces, Juanita; Mazur, Marcus D; Shaffrey, Mark E; Yen, Chun-Po; Shaffrey, Christopher I; Smith, Justin S

    2018-06-16

    Pedicle subtraction osteotomy (PSO) is an effective technique to correct fixed sagittal malalignment. A variation of this technique, the "trans-discal" or "extended" PSO (Schwab grade IV osteotomy), involves extending the posterior wedge resection of the index vertebra to include the superior adjacent disc for radical discectomy. The posterior wedge may be resected in asymmetric fashion to correct concurrent global coronal malalignment.This video illustrates the technical nuances of an extended asymmetrical lumbar PSO for adult spinal deformity. A 62-yr-old female with multiple prior lumbar fusions presented with worsening back pain and posture. Preoperative scoliosis X-rays demonstrated severe global sagittal and coronal malalignment (sagittal vertical axis [SVA, C7-plumbline] of 13.5 cm, pelvic incidence [PI] of 60°, lumbar lordosis [LL] of 14° [in kyphosis], pelvic tilt [PT] of 61°, thoracic kyphosis [TK] of 18°, and rightward coronal shift of 9.3 cm). The patient gave informed consent to surgery and for use of her imaging for medical publication. Briefly, surgery first involved transpedicular instrumentation from T10 to S1 with bilateral iliac screw fixation, and then T11-12 and T12-L1 Smith-Petersen osteotomies were performed. Next, an extended asymmetrical L4 PSO was performed and a 12° lordotic cage (9 × 14 × 40 mm) was placed at the PSO defect. Rods were placed from T10 to iliac bilaterally, and accessory supplemental rods spanning the PSO were attached. Postoperative scoliosis X-rays demonstrated improved alignment: SVA 5.5 cm, PI 60°, LL 55°, PT 36°, TK 37°, and 3.7 cm of rightward coronal shift. The patient had uneventful recovery.

  1. Buccal mucosal graft urethroplasty in long segment anterior urethral stricture - is it gold standard?

    PubMed

    Kumar, Suresh; Bansal, Punit; Vijay, Mukesh K; Dutta, Arindam; Tiwari, Punit; Sharma, Pramod K; Goel, Amit; Bera, Malay K; Kundu, Anup K; Hazra, Avijit

    2013-01-01

    To assess the success of dorsal onlay buccal mucosal graft (BMG) urethroplasty in long segment anterior urethral stricture extending from external meatus to bulbar urethra). We studied 40 patients with long segment anterior urethral stricture, who underwent substitution urethroplasty using dorsal onlay BMG from January 2002 to December 2007. The patients were in the age range of 15-65 years (mean 35 years) in the LS group and 16-63 years (mean 34 years) in the non-lichen sclerosus (NLS) group. The cause of stricture was LS in 20 and NLS (inflammatory and idiopathic) in the other 20 patients. The mean stricture length was 14.5 cm (range 12-17 cm) in the LS group while it was 14.0 cm (range 12-16 cm) in the NLS group. The patients were evaluated with antegrade, retrograde urethrograms and sono-urethrograms and they were followed- up with uroflometery at three months for one year, then six- monthly for two years and then annually. The contrast studies were repeated at six-monthly intervals for one year and then annually for one year. Success was defined as normal voiding pattern without any intervention post-operatively. Median follow-up was 48 months (18-72 months) in the LS group, while it was 42 months (12-72 months) in the NLS group. Among the NLS group patients, three patients developed restricture on follow-up, while seven patients among the LS group developed restricture. We conclude that the high percentage of recurrence of strictures (35%) among the LS group renders BMG urethroplasty in long segment anterior urethral stricture an unacceptable solution, and it needs further study.

  2. Wide spectral range confocal microscope based on endlessly single-mode fiber.

    PubMed

    Hubbard, R; Ovchinnikov, Yu B; Hayes, J; Richardson, D J; Fu, Y J; Lin, S D; See, P; Sinclair, A G

    2010-08-30

    We report an endlessly single mode, fiber-optic confocal microscope, based on a large mode area photonic crystal fiber. The microscope confines a very broad spectral range of excitation and emission wavelengths to a single spatial mode in the fiber. Single-mode operation over an optical octave is feasible. At a magnification of 10 and λ = 900 nm, its resolution was measured to be 1.0 μm (lateral) and 2.5 μm (axial). The microscope's use is demonstrated by imaging single photons emitted by individual InAs quantum dots in a pillar microcavity.

  3. Endoscopy in neuro-otologic surgery.

    PubMed

    Wackym, Phillip A; King, Wesley A; Meyer, Glenn A; Poe, Dennis S

    2002-04-01

    Endoscopy offers several distinct advantages over the operating microscope during neuro-otologic surgery that make it an excellent adjunctive tool to the microscope or independent modality during cranial base surgery. The high magnification gives excellent definition of perforating blood vessels, cranial nerves, and neural structures, which in many cases is superior to that achieved with the microscope. Furthermore, the use of angled or flexible endoscopes allows one to look around corners and behind anatomic structures blocking the view seen via a 0 degree microscope. Endoscopy also has the theoretical advantage that a less invasive operative procedure is required, which should reduce the operative morbidity. Several notable disadvantages of endoscopy include the problems associated with blood soiling the endoscope, making visualization difficult or impossible, the lack of readily available instrumentation designed specifically for endoscopic neuro-otology, and the poor overview of the operative field. This last point is an important one because the endoscope is placed adjacent to the lesion and does not allow one to look backward to prevent [figure: see text] injury to structures next to the shaft of the telescope. Furthermore, the surgeon must be cognizant of potential thermal injury to structures caused by the heat generated by the light source. The present endoscopic technology limits the image that the surgeon sees to two dimensions, which results in certain unique problems when operating in a three-dimensional milieu. Because of this, there is a steep learning curve to acquire endoscopic dexterity and three-dimensional orientation. Finally, bimanual operation requires the use of an articulated endoscope holder or the commitment of the co-surgeon to hold the endoscope. One of the limitations of the operative microscope is that the angle of view is determined by the distance of the lens to the skull, retractor, or obstructing tissue, which is a function of the lens focal length; the longer the focal length, the narrower the viewing angle. During most microsurgical procedures, the focal distance varies between 200 and 400 mm. Using a previous analogy, if one looks through a door's keyhole at close range, nearly the entire room on the opposite side of the door can be seen, although nothing can be seen when the hole is viewed from a long distance. This is similar to what happens when using the endoscope with focal lengths ranging from 5 to 20 mm: a wider angle of view can be achieved. Based on their, experience the authors believe that endoscopes can be used safely during neuro-otologic surgery. As an adjunct to or substitution for the operative microscope, this modality does improve visualization of bony, neural, and vascular structures while minimizing cerebellar retraction.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhlmann, Andreas V.; Houel, Julien; Warburton, Richard J.

    Optically active quantum dots, for instance self-assembled InGaAs quantum dots, are potentially excellent single photon sources. The fidelity of the single photons is much improved using resonant rather than non-resonant excitation. With resonant excitation, the challenge is to distinguish between resonance fluorescence and scattered laser light. We have met this challenge by creating a polarization-based dark-field microscope to measure the resonance fluorescence from a single quantum dot at low temperature. We achieve a suppression of the scattered laser exceeding a factor of 10{sup 7} and background-free detection of resonance fluorescence. The same optical setup operates over the entire quantum dotmore » emission range (920–980 nm) and also in high magnetic fields. The major development is the outstanding long-term stability: once the dark-field point has been established, the microscope operates for days without alignment. The mechanical and optical designs of the microscope are presented, as well as exemplary resonance fluorescence spectroscopy results on individual quantum dots to underline the microscope's excellent performance.« less

  5. MIDAS: Lessons learned from the first spaceborne atomic force microscope

    NASA Astrophysics Data System (ADS)

    Bentley, Mark Stephen; Arends, Herman; Butler, Bart; Gavira, Jose; Jeszenszky, Harald; Mannel, Thurid; Romstedt, Jens; Schmied, Roland; Torkar, Klaus

    2016-08-01

    The Micro-Imaging Dust Analysis System (MIDAS) atomic force microscope (AFM) onboard the Rosetta orbiter was the first such instrument launched into space in 2004. Designed only a few years after the technique was invented, MIDAS is currently orbiting comet 67P Churyumov-Gerasimenko and producing the highest resolution 3D images of cometary dust ever made in situ. After more than a year of continuous operation much experience has been gained with this novel instrument. Coupled with operations of the Flight Spare and advances in terrestrial AFM a set of "lessons learned" has been produced, cumulating in recommendations for future spaceborne atomic force microscopes. The majority of the design could be reused as-is, or with incremental upgrades to include more modern components (e.g. the processor). Key additional recommendations are to incorporate an optical microscope to aid the search for particles and image registration, to include a variety of cantilevers (with different spring constants) and a variety of tip geometries.

  6. [Experimental study of repairing bone defect with tissue engineered bone seeded with autologous red bone marrow and wrapped by pedicled fascial flap].

    PubMed

    Yang, Xinming; Shi, Wei; Du, Yakun; Meng, Xianyong; Yin, Yanlin

    2009-10-01

    To investigate the effect of repairing bone defect with tissue engineered bone seeded with the autologous red bone marrow (ARBM) and wrapped by the pedicled fascial flap and provide experimental foundation for clinical application. Thirty-two New Zealand white rabbits (male and/or female) aged 4-5 months old and weighing 2.0-2.5 kg were used to make the experimental model of bilateral 2 cm defect of the long bone and the periosteum in the radius. The tissue engineered bone was prepared by seeding the ARBM obtained from the rabbits on the osteoinductive absorbing material containing BMP. The left side of the experimental model underwent the implantation of autologous tissue engineered bone serving as the control group (group A). While the right side was designed as the experimental group (group B), one 5 cm x 3 cm fascial flap pedicled on the nameless blood vessel along with its capillary network adjacent to the bone defect was prepared using microsurgical technology, and the autologous tissue engineered bone wrapped by the fascial flap was used to fill the bone defect. At 4, 8, 12, and 16 weeks after operation, X-ray exam, absorbance (A) value test, gross morphology and histology observation, morphology quantitative analysis of bone in the reparative area, vascular image analysis on the boundary area were conducted. X-ray films, gross morphology observation, and histology observation: group B was superior to group A in terms of the growth of blood vessel into the implant, the quantity and the speed of the bone trabecula and the cartilage tissue formation, the development of mature bone structure, the remodeling of shaft structure, the reopen of marrow cavity, and the absorbance and degradation of the implant. A value: there was significant difference between two groups 8, 12, and 16 weeks after operation (P < 0.05), and there were significant differences among those three time points in groups A and B (P < 0.05). For the ratio of neonatal trabecula area to the total reparative area, there were significant differences between two groups 4, 8, 12, and 16 weeks after operation (P < 0.05), and there were significant differences among those four time points in group B (P < 0.05). For the vascular regenerative area in per unit area of the junctional zone, group B was superior to group A 4, 8, 12, and 16 weeks after operation (P < 0.05). Tissue engineered bone, seeded with the ARBM and wrapped by the pedicled fascial flap, has a sound reparative effect on bone defect due to its dual role of constructing vascularization and inducing membrane guided tissue regeneration.

  7. VizieR Online Data Catalog: Astron low resolution UV spectra (Boyarchuk+, 1994)

    NASA Astrophysics Data System (ADS)

    Boyarchuk, A. A.

    2017-05-01

    Astron was a Soviet spacecraft launched on 23 March 1983, and it was operational for eight years as the largest ultraviolet space telescope during its lifetime. Astron's payload consisted of an 80 cm ultraviolet telescope Spica and an X-ray spectroscope. We present 159 low resolution spectra of stars obtained during the Astron space mission (Tables 4, 5; hereafter table numbers in Boyarchuk et al. 1994 are given). Table 4 (observational log, logs.dat) contains data on 142 sessions for 90 stars (sorted in ascending order of RA), where SED was obtained by scanning method, and then data on 17 sessions for 15 stars (also sorted in ascending order of RA), where multicolor photometry was done. Kilpio et al. (2016, Baltic Astronomy 25, 23) presented results of the comparison of Astron data to the modern UV stellar data, discussed Astron precision and accuracy, and made some conclusions on potential application areas of these data. Also 34 sessions of observations of 27 stellar systems (galaxies and globular clusters) are presented. Observational log was published in Table 10 and data were published in Table 11, respectively. Also 16 sessions of observations of 12 nebulae (Table 12 for observational log and Table 13 for data themselves) are presented. Background radiation intensity data (Table 14) are presented in Table 15. At last, data on comets are presented in different forms. We draw your attention that observational data for stars, stellar systems, nebulae and comets are expressed in log [erg/s/cm^2/A], while for comets data 10E-13 erg/s/cm^2/A units are used, hydroxyl band photometric data for comets are expressed in log [erg/s/cm^2], and for the background data it is radiation intensity expressed in log [erg/s/cm^2/A/sr]. Scanned (PDF version of) Boyarchuk et al. (1994) book is available at http://www.inasan.ru/~astron/astron.pdf (12 data files).

  8. Rationale and study design of PROVHILO - a worldwide multicenter randomized controlled trial on protective ventilation during general anesthesia for open abdominal surgery.

    PubMed

    Hemmes, Sabrine N T; Severgnini, Paolo; Jaber, Samir; Canet, Jaume; Wrigge, Hermann; Hiesmayr, Michael; Tschernko, Edda M; Hollmann, Markus W; Binnekade, Jan M; Hedenstierna, Göran; Putensen, Christian; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2011-05-06

    Post-operative pulmonary complications add to the morbidity and mortality of surgical patients, in particular after general anesthesia >2 hours for abdominal surgery. Whether a protective mechanical ventilation strategy with higher levels of positive end-expiratory pressure (PEEP) and repeated recruitment maneuvers; the "open lung strategy", protects against post-operative pulmonary complications is uncertain. The present study aims at comparing a protective mechanical ventilation strategy with a conventional mechanical ventilation strategy during general anesthesia for abdominal non-laparoscopic surgery. The PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure ("PROVHILO") trial is a worldwide investigator-initiated multicenter randomized controlled two-arm study. Nine hundred patients scheduled for non-laparoscopic abdominal surgery at high or intermediate risk for post-operative pulmonary complications are randomized to mechanical ventilation with the level of PEEP at 12 cmH(2)O with recruitment maneuvers (the lung-protective strategy) or mechanical ventilation with the level of PEEP at maximum 2 cmH(2)O without recruitment maneuvers (the conventional strategy). The primary endpoint is any post-operative pulmonary complication. The PROVHILO trial is the first randomized controlled trial powered to investigate whether an open lung mechanical ventilation strategy in short-term mechanical ventilation prevents against postoperative pulmonary complications. ISRCTN: ISRCTN70332574.

  9. Electrical and optical performance of midwave infrared InAsSb heterostructure detectors

    NASA Astrophysics Data System (ADS)

    Gomółka, Emilia; Kopytko, Małgorzata; Markowska, Olga; Michalczewski, Krystian; Kubiszyn, Łukasz; Kębłowski, Artur; Jureńczyk, Jarosław; Gawron, Waldemar; Martyniuk, Piotr Marcin; Piotrowski, Józef; Rutkowski, Jarosław; Rogalski, Antoni

    2018-02-01

    We investigate the high-operating temperature performance of InAsSb/AlSb heterostructure detectors with cutoff wavelengths near 5 μm at 230 K. The devices have been fabricated with different types of absorbing layers: nominally undoped absorber (with n-type conductivity), and both n- and p-type doped. The results show that the device performance strongly depends on absorber layer type. Generally, the p-type absorber provides higher values of current responsivity than the n-type absorber, but at the same time also higher values of dark current. The device with the nominally undoped absorbing layer shows moderate values of both current responsivity and dark current. Resulting detectivities D * of nonimmersed devices vary from 2 × 109 to 5 × 109 cm Hz1/2 W ? 1 at 230 K, which is easily achievable with a two-stage thermoelectric cooler. Optical immersion increases the detectivity up to 5 × 1010 cm Hz1/2 W ? 1.

  10. Millimeter-wave reflectometry for electron density profile and fluctuation measurements on NSTX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kubota, S.; Nguyen, X. V.; Peebles, W. A.

    2001-01-01

    A millimeter-wave reflectometry system for electron density profile and fluctuation measurements is being developed and installed on the National Spherical Torus Experiment. The initial frequency coverage will be in the bands 12--18, 20--32, and 33--50 GHz, provided by frequency-tunable solid-state sources. These frequencies correspond to O-mode cutoff densities ranging from 1.8x10{sup 12} to 3.1x10{sup 13}cm{sup -3}, which will span both the plasma core ({rho}=r/a<0.8) and edge ({rho}>0.8) regions. Operated as a broadband swept-frequency (frequency-modulated continuous-wave) reflectometer, the diagnostic is expected to provide routine (shot-to-shot) time- ({<=}50 {mu}s) and spatially resolved ({approx}1 cm) density profiles. The previous hardware can be easilymore » reconfigured as a fixed-frequency reflectometer for density fluctuation measurements. The combination of measurements would be valuable for studying phenomena such as possible L- to H-mode transitions and edge-localized modes.« less

  11. The intra-umbilical approach in umbilical hernia.

    PubMed

    Arslan, Sukru; Korkut, Ercan

    2014-02-01

    To investigate the "intra-umbilical incision", a smaller incision compared to classic incisions, in cases of umbilical hernia, and which we believe will contribute to patient satisfaction in aesthetic terms, and also the practicability of such operations. The umbilical margins of eight patients with an umbilical hernia were marked between the levels of 6 and 12 o'clock, and a median intra-umbilical skin incision was performed between these two points. In some cases, where exploration could not be performed sufficiently, the incision was extended horizontally from 6 or 12 o'clock. Hernia repair and mesh placement was then performed using an intra-umbilical approach. Patients were investigated according to the defect size and requirement for intra-umbilical incision extension. No requirement for intra-umbilical incision was encountered in six patients with a facial defect diameter smaller than 4 cm, while the incision had to be extended in two patients with defects greater than 4 cm. The intra-umbilical approach in umbilical hernia surgery is aesthetically superior to classical approaches and is a practicable technique.

  12. Histomorphometric and Ultrastructural Evaluation of Long-Term Alpha Lipoic Acid and Vitamin B12 Use After Experimental Sciatic Nerve Injury in Rats.

    PubMed

    Arikan, Murat; Togral, Guray; Hasturk, Askin Esen; Horasanli, Bahriye; Helvacioglu, Fatma; Dagdeviren, Atilla; Tekindal, Mustafa Agah; Parpucu, Murat

    2016-01-01

    To analyze the therapeutic effects of long-term alpha lipoic acid (A-LA) and vitamin B12 use via histomorphometric methods and electron microscopy in the transected sciatic nerves of rats. Forty rats were randomized into five groups (n=8/group). In group I, 1 cm segment of sciatic nerve was resected without any other intervention. In group II (sham), following right sciatic nerve transection, primary epineurial anastomosis was performed by placing the edges of the nerve end-to-end. In group III (saline), after right sciatic nerve transection, the ends of the nerves were brought together and closed after application of intraperitoneal physiologic saline. In group IV, 2 mg/kg of alpha lipoic acid and in group V, 2 mg/kg of vitamin B12 was administered intraperitoneally before surgical intervention. Histomorphometric and electron microscopic analyses revealed that vitamin B12 did not prevent structural changes, abnormal myelination and g-ratio deviations regarding the functional aspects of the sciatic nerve. Alpha lipoic acid was more effective in restructuring the histomorphometric and structural aspects of the nerve with more myelinated fibers with optimal values (0.55-0.68) than vitamin B12 groups, in which the number of myelinated nerve fibers significantly decreased at optimal intervals (0.55-0.68). A-LA administration following peripheral nerve transection injury is more effective in promoting nerve healing regarding the structural aspects of the sciatic nerve compared to vitamin B12 and also myelination of nerve fibers by increasing g-values.

  13. GAP/CL-20-Based Compound Explosive: A New Booster Formulation Used in a Small-Sized Initiation Network

    NASA Astrophysics Data System (ADS)

    Yanju, Wei; Jingyu, Wang; Chongwei, An; Hequn, Li; Xiaomu, Wen; Binshuo, Yu

    2017-01-01

    With ε-2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (CL-20) and glycidyl azide polymer (GAP) as the solid filler and binder, respectively, GAP/CL-20-based compound explosives were designed and prepared. Using micro injection charge technology, the compound explosives were packed into small grooves to explore their application in a small-sized initiation network. The detonation reliability, detonation velocity, mechanical sensitivity, shock sensitivity, and brisance of the explosive were measured and analyzed. The results show that when the solid content of CL-20 is 82 wt%, the explosive charged in the groove has a smooth surface from a macroscopic view. From a microscopic view, a coarse surface is bonded with many CL-20 particles by GAP binder. The GAP/CL-20-based explosive charge successfully generates detonation waves in a groove larger than 0.6 mm × 0.6 mm. When the charge density in the groove is 1.68 g.cm-3 (90% theoretical maximum density), the detonation velocity reaches 7,290 m.s-1. Moreover, this kind of explosive is characterized by low impact and shock sensitivity.

  14. A standard dose of radiation for microscopic disease is not appropriate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marks, L.B.

    1990-12-15

    Elective irradiation of sites of potential occult tumor spread is often part of a patient's radiation therapy program. The required radiation dose (D) depends on the probability that occult disease exists (P(occ)), the number of sites at risk (A), the number of tumor clonogens present (Ni), their radiation sensitivity, and the desired control rate. An exponential model of cell survival is used to quantify the importance of these factors. Control Probability = (1 - Pocc x (1 - e-Ni x (SF2)D/2))A; SF2 = surviving fraction after 2 Gy. Implications for clinical radiation therapy include: 1. Since the number of clonogensmore » in an occult site may vary from 10 degrees to 10(8), Ni is the major determinant of the required dose. The intrinsic radiation sensitivity of the clonogens (SF2) is also extremely important in determining the dose. Other factors are less influential since they vary less. 2. The variability of Ni (8 logs) is larger than the variation in cell number seen with gross disease (1 cm3 versus 1000 cm3, 3 logs). When Ni approximately 10(8), the required dose approaches that needed for small volume gross disease (10(9) cells, 1 cm3). 3. The dose prescribed to elective sites should reflect the risk of occult disease based on the primary tumor site, stage, and grade. 4. Regions where clinicoradiologic evaluation is difficult (e.g., pelvis and obese neck) require higher doses because macroscopic tumor deposits may exist. 5. Relatively low doses (10 to 30 Gy) are often thought to be inadequate for microscopic tumor. However, similar doses have been reported to sterilize microscopic tumor in ovarian, rectal, bladder, breast, and head and neck carcinomas. Relatively low doses should not be discounted since they may be useful in select cases when normal tissue tolerances and/or previous irradiation treatment limit the radiation dose.« less

  15. The Small Whiskbroom Imager for atmospheric compositioN monitorinG (SWING) and its operations from an unmanned aerial vehicle (UAV) during the AROMAT campaign

    NASA Astrophysics Data System (ADS)

    Merlaud, Alexis; Tack, Frederik; Constantin, Daniel; Georgescu, Lucian; Maes, Jeroen; Fayt, Caroline; Mingireanu, Florin; Schuettemeyer, Dirk; Meier, Andreas Carlos; Schönardt, Anja; Ruhtz, Thomas; Bellegante, Livio; Nicolae, Doina; Den Hoed, Mirjam; Allaart, Marc; Van Roozendael, Michel

    2018-01-01

    The Small Whiskbroom Imager for atmospheric compositioN monitorinG (SWING) is a compact remote sensing instrument dedicated to mapping trace gases from an unmanned aerial vehicle (UAV). SWING is based on a compact visible spectrometer and a scanning mirror to collect scattered sunlight. Its weight, size, and power consumption are respectively 920 g, 27 cm × 12 cm × 8 cm, and 6 W. SWING was developed in parallel with a 2.5 m flying-wing UAV. This unmanned aircraft is electrically powered, has a typical airspeed of 100 km h-1, and can operate at a maximum altitude of 3 km. We present SWING-UAV experiments performed in Romania on 11 September 2014 during the Airborne ROmanian Measurements of Aerosols and Trace gases (AROMAT) campaign, which was dedicated to test newly developed instruments in the context of air quality satellite validation. The UAV was operated up to 700 m above ground, in the vicinity of the large power plant of Turceni (44.67° N, 23.41° E; 116 m a. s. l. ). These SWING-UAV flights were coincident with another airborne experiment using the Airborne imaging differential optical absorption spectroscopy (DOAS) instrument for Measurements of Atmospheric Pollution (AirMAP), and with ground-based DOAS, lidar, and balloon-borne in situ observations. The spectra recorded during the SWING-UAV flights are analysed with the DOAS technique. This analysis reveals NO2 differential slant column densities (DSCDs) up to 13±0.6×1016 molec cm-2. These NO2 DSCDs are converted to vertical column densities (VCDs) by estimating air mass factors. The resulting NO2 VCDs are up to 4.7±0.4×1016 molec cm-2. The water vapour DSCD measurements, up to 8±0.15×1022 molec cm-2, are used to estimate a volume mixing ratio of water vapour in the boundary layer of 0.013±0.002 mol mol-1. These geophysical quantities are validated with the coincident measurements.

  16. A 17 GHz molecular rectifier

    PubMed Central

    Trasobares, J.; Vuillaume, D.; Théron, D.; Clément, N.

    2016-01-01

    Molecular electronics originally proposed that small molecules sandwiched between electrodes would accomplish electronic functions and enable ultimate scaling to be reached. However, so far, functional molecular devices have only been demonstrated at low frequency. Here, we demonstrate molecular diodes operating up to 17.8 GHz. Direct current and radio frequency (RF) properties were simultaneously measured on a large array of molecular junctions composed of gold nanocrystal electrodes, ferrocenyl undecanethiol molecules and the tip of an interferometric scanning microwave microscope. The present nanometre-scale molecular diodes offer a current density increase by several orders of magnitude compared with that of micrometre-scale molecular diodes, allowing RF operation. The measured S11 parameters show a diode rectification ratio of 12 dB which is linked to the rectification behaviour of the direct current conductance. From the RF measurements, we extrapolate a cut-off frequency of 520 GHz. A comparison with the silicon RF-Schottky diodes, architecture suggests that the RF-molecular diodes are extremely attractive for scaling and high-frequency operation. PMID:27694833

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Varinderjit; Vadas, J.; Steinbach, T. K.

    Measuring the fusion excitation function for an isotopic chain of projectile nuclei provides a stringent test of a microscopic description of fusion. We report the first measurement of the fusion excitation function at near-barrier energies for the 19O+ 12C system. The measured excitation function is compared with the fusion excitation function of 18O+ 12C. A significant enhancement in the fusion probability of 19O ions with a 12C target as compared to 18O ions is observed. As a result, the experimental cross-sections observed at near-barrier energies are compared with a state-of-the-art microscopic model.

  18. Heat and fuel coupled operation of a high temperature polymer electrolyte fuel cell with a heat exchanger methanol steam reformer

    NASA Astrophysics Data System (ADS)

    Schuller, G.; Vázquez, F. Vidal; Waiblinger, W.; Auvinen, S.; Ribeirinha, P.

    2017-04-01

    In this work a methanol steam reforming (MSR) reactor has been operated thermally coupled to a high temperature polymer electrolyte fuel cell stack (HT-PEMFC) utilizing its waste heat. The operating temperature of the coupled system was 180 °C which is significantly lower than the conventional operating temperature of the MSR process which is around 250 °C. A newly designed heat exchanger reformer has been developed by VTT (Technical Research Center of Finland LTD) and was equipped with commercially available CuO/ZnO/Al2O3 (BASF RP-60) catalyst. The liquid cooled, 165 cm2, 12-cell stack used for the measurements was supplied by Serenergy A/S. The off-heat from the electrochemical fuel cell reaction was transferred to the reforming reactor using triethylene glycol (TEG) as heat transfer fluid. The system was operated up to 0.4 A cm-2 generating an electrical power output of 427 Wel. A total stack waste heat utilization of 86.4% was achieved. It has been shown that it is possible to transfer sufficient heat from the fuel cell stack to the liquid circuit in order to provide the needed amount for vaporizing and reforming of the methanol-water-mixture. Furthermore a set of recommendations is given for future system design considerations.

  19. InAs/Ga(In)Sb type-II superlattices short/middle dual color infrared detectors

    NASA Astrophysics Data System (ADS)

    Shi, Yanli; Hu, Rui; Deng, Gongrong; He, Wenjing; Feng, Jiangmin; Fang, Mingguo; Li, Xue; Deng, Jun

    2015-06-01

    Short wavelength and middle wavelength dual color infrared detector were designed and prepared with InAs/Ga(In)Sb type-II superlattices materials. The Crosslight software was used to calculate the relation between wavelength and material parameter such as thickness of InAs, GaSb, then energy strucutre of 100 periods 8ML/8ML InAs/GaSb and the absorption wavelength was calculated. After fixing InAs/GaSb thickness parameter, devices with nBn and pin structure were designed and prepared to compare performance of these two structures. Comparison results showed both structure devices were available for high temperature operation which black detectivity under 200K were 7.9×108cmHz1/2/W for nBn and 1.9×109cmHz1/2/W for pin respectively. Considering the simultaneous readout requirement for further FPAs application the NIP/PIN InAs/GaSb dual-color structure was grown by MBE method. Both two mesas and one mesa devices structure were designed and prepared to appreciate the short/middle dual color devices. Cl2-based ICP etching combined with phosphoric acid based chemicals were utilized to form mesas, silicon dioxide was deposited via PECVD as passivation layer. Ti/Au was used as metallization. Once the devices were finished, the electro-optical performance was measured. Measurement results showed that optical spectrum response with peak wavelength of 2.7μm and 4.3μm under 77K temperature was gained, the test results agree well with calculated results. Peak detectivity was measured as 2.08×1011cmHz1/2/W and 6.2×1010cmHz1/2/W for short and middle wavelength infrared detector respectively. Study results disclosed that InAs/Ga(In)Sb type-II SLs is available for both short and middle wavelength infrared detecting with good performance by simply altering the thickness of InAs layer and GaSb layer.

  20. Inspection with Robotic Microscopic Imaging

    NASA Technical Reports Server (NTRS)

    Pedersen, Liam; Deans, Matthew; Kunz, Clay; Sargent, Randy; Chen, Alan; Mungas, Greg

    2005-01-01

    Future Mars rover missions will require more advanced onboard autonomy for increased scientific productivity and reduced mission operations cost. One such form of autonomy can be achieved by targeting precise science measurements to be made in a single command uplink cycle. In this paper we present an overview of our solution to the subproblems of navigating a rover into place for microscopic imaging, mapping an instrument target point selected by an operator using far away science camera images to close up hazard camera images, verifying the safety of placing a contact instrument on a sample or finding nearby safe points, and analyzing the data that comes back from the rover. The system developed includes portions used in the Multiple Target Single Cycle Instrument Placement demonstration at NASA Ames in October 2004, and portions of the MI Toolkit delivered to the Athena Microscopic Imager Instrument Team for the MER mission still operating on Mars today. Some of the component technologies are also under consideration for MSL mission infusion.

Top