Sample records for cm2 effective area

  1. Effect of a commercial steam-vacuuming treatment implemented after slaughtering for the decontamination of cattle carcasses

    PubMed Central

    Hochreutener, Mirjam; Zweifel, Claudio; Corti, Sabrina; Stephan, Roger

    2017-01-01

    To assess the antimicrobial effect of a commercial steam-vacuuming system newly implemented after slaughtering, 105 cattle carcasses were examined for total viable counts (TVC) at four different areas. Before steam vacuuming, mean TVC of the excision samples were comparable at the perineal area and brisket (3.0-3.1 log CFU cm-2) or the hind leg and shoulder (2.6-2.7 log CFU cm-2). Steam vacuuming reduced mean TVC by 0.9, 0.7, 0.6, and 0.4 log CFU cm-2 at the perineal area, hind leg, shoulder, and brisket, respectively. With regard to the distribution of counts, steam vacuuming increased the proportion of TVC results <3.0 log CFU cm-2 from 74.8% (62.9-87.6% at carcass areas) to 86.7% (71.4-97.1% at carcass areas). Thus, steam vacuuming after slaughtering might be useful for the reduction of contamination in designated carcass areas, but the effect must not be overestimated and decontamination treatments always must be seen part of an integral food safety system. PMID:29071245

  2. Microwave ablation with multiple simultaneously powered small-gauge triaxial antennas: results from an in vivo swine liver model.

    PubMed

    Brace, Christopher L; Laeseke, Paul F; Sampson, Lisa A; Frey, Tina M; van der Weide, Daniel W; Lee, Fred T

    2007-07-01

    To prospectively investigate the ability of a single generator to power multiple small-diameter antennas and create large zones of ablation in an in vivo swine liver model. Thirteen female domestic swine (mean weight, 70 kg) were used for the study as approved by the animal care and use committee. A single generator was used to simultaneously power three triaxial antennas at 55 W per antenna for 10 minutes in three groups: a control group where antennas were spaced to eliminate ablation zone overlap (n=6; 18 individual zones of ablation) and experimental groups where antennas were spaced 2.5 cm (n=7) or 3.0 cm (n=5) apart. Animals were euthanized after ablation, and ablation zones were sectioned and measured. A mixed linear model was used to test for differences in size and circularity among groups. Mean (+/-standard deviation) cross-sectional areas of multiple-antenna zones of ablation at 2.5- and 3.0-cm spacing (26.6 cm(2) +/- 9.7 and 32.2 cm(2) +/- 8.1, respectively) were significantly larger than individual ablation zones created with single antennas (6.76 cm(2) +/- 2.8, P<.001) and were 31% (2.5-cm spacing group: multiple antenna mean area, 26.6 cm(2); 3 x single antenna mean area, 20.28 cm(2)) to 59% (3.0-cm spacing group: multiple antenna mean area, 32.2 cm(2); 3 x single antenna mean area, 20.28 cm(2)) larger than 3 times the mean area of the single-antenna zones. Zones of ablation were found to be very circular, and vessels as large as 1.1 cm were completely coagulated with multiple antennas. A single generator may effectively deliver microwave power to multiple antennas. Large volumes of tissue may be ablated and large vessels coagulated with multiple-antenna ablation in the same time as single-antenna ablation. (c) RSNA, 2007.

  3. Effective regurgitant orifice area by the color Doppler flow convergence method for evaluating the severity of chronic aortic regurgitation. An animal study.

    PubMed

    Shiota, T; Jones, M; Yamada, I; Heinrich, R S; Ishii, M; Sinclair, B; Holcomb, S; Yoganathan, A P; Sahn, D J

    1996-02-01

    The aim of the present study was to evaluate dynamic changes in aortic regurgitant (AR) orifice area with the use of calibrated electromagnetic (EM) flowmeters and to validate a color Doppler flow convergence (FC) method for evaluating effective AR orifice area and regurgitant volume. In 6 sheep, 8 to 20 weeks after surgically induced AR, 22 hemodynamically different states were studied. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary EM flowmeters balanced against each other. Instantaneous AR orifice areas were determined by dividing these actual AR flow rates by the corresponding continuous wave velocities (over 25 to 40 points during each diastole) matched for each steady state. Echo studies were performed to obtain maximal aliasing distances of the FC in a low range (0.20 to 0.32 m/s) and a high range (0.70 to 0.89 m/s) of aliasing velocities; the corresponding maximal AR flow rates were calculated using the hemispheric flow convergence assumption for the FC isovelocity surface. AR orifice areas were derived by dividing the maximal flow rates by the maximal continuous wave Doppler velocities. AR orifice sizes obtained with the use of EM flowmeters showed little change during diastole. Maximal and time-averaged AR orifice areas during diastole obtained by EM flowmeters ranged from 0.06 to 0.44 cm2 (mean, 0.24 +/- 0.11 cm2) and from 0.05 to 0.43 cm2 (mean, 0.21 +/- 0.06 cm2), respectively. Maximal AR orifice areas by FC using low aliasing velocities overestimated reference EM orifice areas; however, at high AV, FC predicted the reference areas more reliably (0.25 +/- 0.16 cm2, r = .82, difference = 0.04 +/- 0.07 cm2). The product of the maximal orifice area obtained by the FC method using high AV and the velocity time integral of the regurgitant orifice velocity showed good agreement with regurgitant volumes per beat (r = .81, difference = 0.9 +/- 7.9 mL/beat). This study, using strictly quantified AR volume, demonstrated little change in AR orifice size during diastole. When high aliasing velocities are chosen, the FC method can be useful for determining effective AR orifice size and regurgitant volume.

  4. Cutaneous Sensory Block Area, Muscle-Relaxing Effect, and Block Duration of the Transversus Abdominis Plane Block: A Randomized, Blinded, and Placebo-Controlled Study in Healthy Volunteers.

    PubMed

    Støving, Kion; Rothe, Christian; Rosenstock, Charlotte V; Aasvang, Eske K; Lundstrøm, Lars H; Lange, Kai H W

    2015-01-01

    The transversus abdominis plane (TAP) block is a widely used nerve block. However, basic block characteristics are poorly described. The purpose of this study was to assess the cutaneous sensory block area, muscle-relaxing effect, and block duration. Sixteen healthy volunteers were randomized to receive an ultrasound-guided unilateral TAP block with 20 mL 7.5 mg/mL ropivacaine and placebo on the contralateral side. Measurements were performed at baseline and 90 minutes after performing the block. Cutaneous sensory block area was mapped and separated into a medial and lateral part by a vertical line through the anterior superior iliac spine. We measured muscle thickness of the 3 lateral abdominal muscle layers with ultrasound in the relaxed state and during maximal voluntary muscle contraction. The volunteers reported the duration of the sensory block and the abdominal muscle-relaxing effect. The lateral part of the cutaneous sensory block area was a median of 266 cm2 (interquartile range, 191-310 cm2) and the medial part 76 cm 2(interquartile range, 54-127 cm2). In all the volunteers, lateral wall muscle thickness decreased significantly by 9.2 mm (6.9-15.7 mm) during a maximal contraction. Sensory block and muscle-relaxing effect duration were 570 minutes (512-716 minutes) and 609 minutes (490-724 minutes), respectively. Cutaneous sensory block area of the TAP block is predominantly located lateral to a vertical line through the anterior superior iliac spine. The distribution is nondermatomal and does not cross the midline. The muscle-relaxing effect is significant and consistent. The block duration is approximately 10 hours with large variation.

  5. On-ground calibration of the Hitomi Hard X-ray Telescopes

    NASA Astrophysics Data System (ADS)

    Mori, Hideyuki; Miyazawa, Takuya; Awaki, Hisamitsu; Matsumoto, Hironori; Babazaki, Yasunori; Bandai, Ayako; Demoto, Tadatsugu; Furuzawa, Akihiro; Haba, Yoshito; Hayashi, Takayuki; Iizuka, Ryo; Ishibashi, Kazunori; Ishida, Manabu; Ishida, Naoki; Itoh, Masayuki; Iwase, Toshihiro; Kato, Hiroyoshi; Kobayashi, Hiroaki; Kosaka, Tatsuro; Kunieda, Hideyo; Kurashima, Shou; Kurihara, Daichi; Kuroda, Yuuji; Maeda, Yoshitomo; Meshino, Yoshifumi; Mitsuishi, Ikuyuki; Miyata, Yuusuke; Nagano, Housei; Namba, Yoshiharu; Ogasaka, Yasushi; Ogi, Keiji; Okajima, Takashi; Saji, Shigetaka; Shimasaki, Fumiya; Sato, Takuro; Sato, Toshiki; Shima, Naotsugu; Sugita, Satoshi; Suzuki, Yoshio; Tachibana, Kenji; Tachibana, Sasagu; Takizawa, Shun'ya; Tamura, Keisuke; Tawara, Yuzuru; Tomikawa, Kazuki; Torii, Tatsuharu; Uesugi, Kentaro; Yamashita, Koujun; Yamauchi, Shigeo

    2018-01-01

    We present x-ray characteristics of the Hard X-ray Telescopes (HXTs) on board the Hitomi (ASTRO-H) satellite. Measurements were conducted at the SPring-8 BL20B2 beamline and the ISAS/JAXA 27-m beamline. The angular resolution defined by a half-power diameter was 1.9‧ (HXT-1) and 2.1‧ (HXT-2) at 8 keV, 1.9‧ at 30 keV, and 1.8‧ at 50 keV. The effective area was found to be 620 cm2 at 8 keV, 178 cm2 at 30 keV, and 82 cm2 at 50 keV per mirror module. Although the angular resolutions were slightly worse than the requirement (1.7‧), the effective areas sufficiently exceeded the requirements of 150 cm2 at 30 keV and 55 cm2 at 50 keV. The off-axis measurements of the effective areas resulted in the field of view being 6.1‧ at 50 keV, 7.7‧ at 30 keV, and 9.7‧ at 8 keV in diameter. We confirmed that the main component of the stray x-ray light was significantly reduced by mounting the precollimator as designed. Detailed analysis of the data revealed that the angular resolution was degraded mainly by figure errors of mirror foils, and the angular resolution is completely explained by the figure errors, positioning errors of the foils, and conical approximation of the foil shape. We found that the effective areas were ˜80% of the designed values below 40 keV, whereas they steeply decline above 40 keV and become only ˜50%. We investigated this abrupt decline and found that neither the error of the multilayer design nor the errors of the incident angles induced by the positioning errors of the foils can be the cause. The reflection profile of each foil pair from the defocused image strongly suggests that the figure errors of the foils probably bring about the reduction in the effective areas at higher energies.

  6. Echocardiographic Evaluation of the Right Atrial Area Index in Dogs with Pulmonary Hypertension.

    PubMed

    Vezzosi, T; Domenech, O; Iacona, M; Marchesotti, F; Zini, E; Venco, L; Tognetti, R

    2018-01-01

    Right atrial area (RAA) is a prognostic factor in human patients with pulmonary arterial hypertension (PAH). Reference intervals for RAA have been described in healthy dogs. To evaluate RAA indexed to the body surface area in dogs with PAH as an indicator of right atrial size, PAH severity and right-sided congestive heart failure (R-CHF). A total of 119 client-owned dogs, 48 dogs with PAH and 71 control dogs. Prospective observational study. Pulmonary arterial hypertension was classified according to the tricuspid regurgitation pressure gradient (TRPG) as mild (36-50 mmHg), moderate (51-75 mmHg), or severe (>75 mmHg). The RAA index was calculated as the RAA divided by body surface area. The RAA index was higher in dogs with moderate PAH (13.3 cm 2 /m 2 ; range, 3.4-24.7 cm 2 /m 2 ) and severe PAH (12.1 cm 2 /m 2 ; range, 5.4-21.8 cm 2 /m 2 ) than in those with mild PAH (6.7 cm 2 /m 2 ; range, 4.8-10.7 cm 2 /m 2 ) or in controls (7.3 cm 2 /m 2 ; range, 4.2-10.2 cm 2 /m 2 ; P < 0.001). The RAA index was higher (P < 0.0001) in dogs with R-CHF (17.5 cm 2 /m 2 ; range, 12.7-24.7 cm 2 /m 2 ) compared to those without R-CHF (7.6 cm 2 /m 2 ; range, 4.4-19.4 cm 2 /m 2 ). The most accurate cutoff value of the RAA index to identify R-CHF was >12.3 cm 2 /m 2 (sensitivity, 100%; specificity, 89.5%). In dogs with PAH, severity of tricuspid regurgitation (TR) was the only independent predictor of RAA index based on multivariate analysis (P < 0.02). The RAA index can be used to evaluate right atrial size in dogs and may be more effective than TRPG in predicting R-CHF in dogs with PAH. The severity of TR is the main determinant of the RAA index in dogs with PAH. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  7. Quantifying the radiant exposure and effective dose in patients treated for actinic keratoses with topical photodynamic therapy using daylight and LED white light

    NASA Astrophysics Data System (ADS)

    Manley, M.; Collins, P.; Gray, L.; O'Gorman, S.; McCavana, J.

    2018-02-01

    Daylight photodynamic therapy (dl-PDT) is as effective as conventional PDT (c-PDT) for treating actinic keratoses but has the advantage of reducing patient discomfort significantly. Topical dl-PDT and white light-PDT (wl-PDT) differ from c-PDT by way of light sources and methodology. We measured the variables associated with light dose delivery to skin surface and influence of geometry using a radiometer, a spectral radiometer and an illuminance meter. The associated errors of the measurement methods were assessed. The spectral and spatial distribution of the radiant energy from the LED white light source was evaluated in order to define the maximum treatment area, setup and treatment protocol for wl-PDT. We compared the data with two red LED light sources we use for c-PDT. The calculated effective light dose is the product of the normalised absorption spectrum of the photosensitizer, protoporphyrin IX (PpIX), the irradiance spectrum and the treatment time. The effective light dose from daylight ranged from 3  ±  0.4 to 44  ±  6 J cm-2due to varying weather conditions. The effective light dose for wl-PDT was reproducible for treatments but it varied across the treatment area between 4  ±  0.1 J cm-2 at the edge and 9  ±  0.1 J cm-2 centrally. The effective light dose for the red waveband (615-645 nm) was 0.42  ±  0.05 J cm-2 on a clear day, 0.05  ±  0.01 J cm-2 on an overcast day and 0.9  ±  0.01 J cm-2 using the white light. This compares with 0.95  ±  0.01 and 0.84  ±  0.01 J cm-2 for c-PDT devices. Estimated errors associated with indirect determination of daylight effective light dose were very significant, particularly for effective light doses less than 5 J cm-2 (up to 83% for irradiance calculations). The primary source of error is in establishment of the relationship between irradiance or illuminance and effective dose. Use of the O’Mahoney model is recommended using a calibrated logging illuminance meter with the detector in the plane of the treatment area.

  8. Effects of arbuscular mycorrhizal fungi on seedling growth and development of two wetland plants, Bidens frondosa L., and Eclipta prostrata (L.) L., grown under three levels of water availability.

    PubMed

    Stevens, Kevin J; Wall, Christopher B; Janssen, Joel A

    2011-05-01

    To identify the importance of arbuscular mycorrhizal fungi (AMF) colonizing wetland seedlings following flooding, we assessed the effects of AMF on seedling establishment of two pioneer species, Bidens frondosa and Eclipta prostrata grown under three levels of water availability and ask: (1) Do inoculated seedlings differ in growth and development from non-inoculated plants? (2) Are the effects of inoculation and degree of colonization dependent on water availability? (3) Do plant responses to inoculation differ between two closely related species? Inoculation had no detectable effects on shoot height, or plant biomass but did affect biomass partitioning and root morphology in a species-specific manner. Shoot/root ratios were significantly lower in non-inoculated E. prostrata plants compared with inoculated plants (0.381 ± 0.066 vs. 0.683 ± 0.132). Root length and surface area were greater in non-inoculated E. prostrata (259.55 ± 33.78 cm vs. 194.64 ± 27.45 cm and 54.91 ± 7.628 cm(2) vs. 46.26 ± 6.8 cm(2), respectively). Inoculation had no detectable effect on B. frondosa root length, volume, or surface area. AMF associations formed at all levels of water availability. Hyphal, arbuscular, and vesicular colonization levels were greater in dry compared with intermediate and flooded treatments. Measures of mycorrhizal responsiveness were significantly depressed in E. prostrata compared with B. frondosa for total fresh weight (-0.3 ± 0.18 g vs. 0.06 ± 0.06 g), root length (-0.78 ± 0.28 cm vs.-0.11 ± 0.07 cm), root volume (-0.49 ± 0.22 cm(3) vs. 0.06 ± 0.07 cm(3)), and surface area (-0.59 ± 0.23 cm(2) vs.-0.03 ± 0.08 cm(2)). Given the disparity in species response to AMF inoculation, events that alter AMF prevalence in wetlands could significantly alter plant community structure by directly affecting seedling growth and development.

  9. Systematic analysis of the scatter environment in clinical intra-operative high dose rate (IOHDR) brachytherapy

    NASA Astrophysics Data System (ADS)

    Oh, Moonseong

    Most brachytherapy planning systems are based on a dose calculation algorithm that assumes an infinite scatter environment surrounding the target volume and applicator. In intra-operative high dose rate brachytherapy (IOHDR) where treatment catheters are typically laid either directly on a tumor bed or within applicators that may have little or no scatter material above them, the lack of scatter from one side of the applicator can result in serious underdosage during treatment. Therefore, full analyses of the physical processes such as the photoelectric effect, Rayleigh, and Compton scattering that contribute to dosimetric errors have to be investigated and documented to result in more accurate treatment delivery to patients undergoing IOHDR procedures. Monte Carlo simulation results showed the Compton scattering effect is about 40 times more probable than photoelectric effect for the treated areas of single source, 4 x 4, and 2 x 4 cm2. Also, the dose variations with and without photoelectric effect were 0.3 ˜ 0.7%, which are within the uncertainty in Monte Carlo simulations. Also, Monte Carlo simulation studies were done to verify the following experimental results for quantification of dosimetric errors in clinical IOHDR brachytherapy. The first experimental study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in IOHDR brachytherapy. Treatment plans were developed for 3 different treatment surface areas (4 x 4, 7 x 7, 12 x 12 cm2), each with prescription points located at 3 distances (0.5 cm, 1.0 cm, and 1.5 cm) from the source dwell positions. Measurements showed that the magnitude of the underdosage varies from about 8% to 13% of the prescription dose as the prescription depth is increased from 0.5 cm to 1.5 cm. This treatment error was found to be independent of the irradiated area and strongly dependent on the prescription distance. The study was extended to confirm the underdosage for various shape of treated area (especially, irregular shape), which can be applied in clinical cases. Treatment plans of 10 patients previously treated at Roswell Park Cancer Institute in Buffalo, which had irregular shapes of treated areas, were used. In IOHDR brachytherapy, a 2-dimensional (2-D) planar geometry is typically used without considering the curved shape of target surfaces. In clinical cases, this assumption of the planar geometry may cause the serious dose delivery errors to target volumes. The second study was performed to investigate the dose errors to curved surfaces. Seven rectangular shaped plans (five for 1.0 cm and two for 0.5 cm prescription depth) and archived irregular shaped plans of 2 patients were analyzed. Cylindrical phantoms with six radii (ranged 1.35 to 12.5 cm) were used to simulate the treatment planning geometries, which were calculated in 2-D plans. Actual doses delivered to prescription points were over-estimated up to 15% on the concave side of curved applicators for all cylindrical phantoms with 1.0 cm prescription depth. Also, delivered doses decreased by up to 10% on the convex side of curved applicators for small treated areas (≤ 5catheters), but interestingly, any dose dependence was not shown with large treated areas. Our measurements have shown inaccuracy in dose delivery when the original planar treatment plan was delivered in a curved applicator setting. Dose errors arising due to the tumor curvature may be significant in a clinical set up and merit attention during planning.

  10. Randomized clinical trial of facial acupuncture with or without body acupuncture for treatment of melasma.

    PubMed

    Rerksuppaphol, Lakkana; Charoenpong, Theekapun; Rerksuppaphol, Sanguansak

    2016-02-01

    To evaluate the efficacy of acupuncture treatments in treating facial melasma, contrasting treatments involving facial acupuncture with facial/body acupuncture. Women suffering with melasma were randomly assigned into: 1) facial acupuncture (n = 20); or 2) facial/body acupuncture (n = 21). Each group was given 2 sessions per week for 8 weeks. Melasma area and darkness of its pigmentation were assessed using digital images. 95.2% and 90% of participants in facial/body and facial acupuncture, respectively, had decreased melasma areas, with a mean reduction area being 2.6 cm(2) (95%CI 1.6-3.6 cm(2)) and 2.4 cm(2) (95%CI 1.6-3.3 cm(2)), respectively. 66.7% (facial/body acupuncture) and 80.0% (facial acupuncture) of participants had lighter melasma pigmentation compared to their baselines (p-value = 0.482). Facial acupuncture, with or without body acupuncture, was shown to be effective in decreasing the size of melasma areas. This study is registered with the Thai Clinical Trial Registry (TCTR20140903004). Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Contrast-enhanced magnetic resonance angiography: first-pass arterial enhancement as a function of gadolinium-chelate concentration, and the saline chaser volume and injection rate.

    PubMed

    Husarik, Daniela B; Bashir, Mustafa R; Weber, Paul W; Nichols, Eli B; Howle, Laurens E; Merkle, Elmar M; Nelson, Rendon C

    2012-02-01

    To evaluate the effect of the contrast medium (CM) concentration and the saline chaser volume and injection rate on first-pass aortic enhancement characteristics in contrast-enhanced magnetic resonance angiography using a physiologic flow phantom. Imaging was performed on a 3.0-T magnetic resonance system (MAGNETOM Trio, Siemens Healthcare Solutions, Inc, Erlangen, Germany) using a 2-dimensional fast low angle shot T1-weighted sequence (repetition time, 500 milliseconds; echo time, 1.23 milliseconds; flip angle, 8 degrees; 1 frame/s × 60 seconds). The following CM concentrations injected at 2 mL/s were used with 3 different contrast agents (gadolinium [Gd]-BOPTA, Gd-HP-DO3A, Gd-DTPA): 20 mL of undiluted CM (100%) and 80%, 40%, 20%, 10%, 5%, and 2.5% of the full amount, all diluted in saline to a volume of 20 mL to ensure equal bolus volume. The CM was followed by saline chasers of 20 to 60 mL injected at 2 mL/s and 6 mL/s. Aortic signal intensity (SI) was measured, and normalized SI versus time (SI/Tn) curves were generated. The maximal SI (SI(max)), bolus length, and areas under the SI/Tn curve were calculated. Decreasing the CM concentration from 100% to 40% resulted in a decrease of SI(max) to 86.1% (mean). Further decreasing the CM concentration to 2.5% decreased SI(max) to 5.1% (mean). Altering the saline chaser volume had no significant effect on SI(max). Increasing the saline chaser injection rate had little effect (mean increase, 2.2%) on SI(max) when using ≥40% of CM. There was a larger effect (mean increase, 19.6%) when ≤20% of CM were used. Bolus time length was significantly shorter (P < 0.001), and area under the SI/T(n) curve was significantly smaller (P < 0.01) for the CM protocols followed by a saline chaser injected at 6 mL/s compared with a saline chaser injected at 2 mL/s. With 40% of CM and a fast saline chaser, SImax close to that with undiluted CM can be achieved. An increased saline chaser injection rate has a more pronounced effect on aortic enhancement characteristics at lower CM concentrations than at higher CM concentrations.

  12. Graphene-coated carbon fiber cloth for flexible electrodes of glucose fuel cells

    NASA Astrophysics Data System (ADS)

    Hoshi, Kazuki; Muramatsu, Kazuo; Sumi, Hisato; Nishioka, Yasushiro

    2016-02-01

    In this work, we fabricated flexible electrodes for a miniaturized, simple structured, and flexible glucose biofuel cell (BFC) using a graphene-coated carbon fiber cloth (GCFC). The areas of the anode and cathode electrodes were 3 × 10 mm2. The anode area was coated with the enzyme glucose oxidase, and the cathode area was coated with the enzyme bilirubin oxidase. No ion-exchange film was needed because glucose oxidase selectively oxidizes glucose and bilirubin oxidase selectively reduces oxygen. The power density of the BFC with GCFC electrodes in a phosphate buffer solution of 200 mM glucose solution at room temperature was 34.3 µW/cm2 at 0.43 V. The power density of a BFC using carbon fiber cloth (CFC) without graphene modification was 18.5 µW/cm2 at 0.13 V. The BFC with the GCFC electrode continued to function longer than 24 h with a power density higher than 5 µW/cm2. These effects were attributed to the much larger effective surface areas of the GCFC electrodes that maintain more enzymes than those of the CFC electrodes.

  13. Echocardiographic features of the normofunctional Labcor-Santiago pericardial bioprosthesis.

    PubMed

    Gonzalez-Juanatey, J R; Garcia-Bengoechea, J B; Vega, M; Rubio, J; Sierra, J; Duran, D; Amaro, A; Gil, M

    1994-09-01

    Echocardiography was performed in 94 patients with a total of 99 normally functioning Labcor-Santiago bioprostheses, 62 in the aortic and 37 in the mitral position. The following variables were measured: peak and mean transvalvular velocities, peak and mean instantaneous pressure gradients as calculated from the modified Bernoulli equation, pressure half-time, cardiac index, stroke volume and effective orifice area (using continuity and Hatle equations). Regurgitation patterns were sought by transthoracic echocardiography (all valves) and, for selected mitral bioprostheses, by transesophageal echocardiography. Calculated mean aortic pressure gradient ranged from six to 10 mmHg and calculated effective aortic orifice area increased with ring diameter, with means of 1.27 cm2 for the 19 mm valve and 2.58 cm2 for the 27 mm valve. For mitral bioprostheses, mean pressure gradient ranged from 3.0 to 4.5 mmHg and calculated effective orifice area from 2.27 to 2.73 cm2. Only central regurgitation was observed. The Labcor-Santiago pericardial bioprostheses created little resistance to forward flow. In the small aortic root their hemodynamic performance was as good or better than that of other currently available devices. It is hoped that this new design will contribute increased in vivo mechanical durability.

  14. [An investigation of ionizing radiation dose in a manufacturing enterprise of ion-absorbing type rare earth ore].

    PubMed

    Zhang, W F; Tang, S H; Tan, Q; Liu, Y M

    2016-08-20

    Objective: To investigate radioactive source term dose monitoring and estimation results in a manufacturing enterprise of ion-absorbing type rare earth ore and the possible ionizing radiation dose received by its workers. Methods: Ionizing radiation monitoring data of the posts in the control area and supervised area of workplace were collected, and the annual average effective dose directly estimated or estimated using formulas was evaluated and analyzed. Results: In the control area and supervised area of the workplace for this rare earth ore, α surface contamination activity had a maximum value of 0.35 Bq/cm 2 and a minimum value of 0.01 Bq/cm 2 ; β radioactive surface contamination activity had a maximum value of 18.8 Bq/cm 2 and a minimum value of 0.22 Bq/cm 2 . In 14 monitoring points in the workplace, the maximum value of the annual average effective dose of occupational exposure was 1.641 mSv/a, which did not exceed the authorized limit for workers (5 mSv/a) , but exceeded the authorized limit for general personnel (0.25 mSv/a) . The radionuclide specific activity of ionic mixed rare earth oxides was determined to be 0.9. Conclusion: The annual average effective dose of occupational exposure in this enterprise does not exceed the authorized limit for workers, but it exceeds the authorized limit for general personnel. We should pay attention to the focus of the radiation process, especially for public works radiation.

  15. Controlled Growth of Large-Area Aligned Single-Crystalline Organic Nanoribbon Arrays for Transistors and Light-Emitting Diodes Driving

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Wang, Liang; Dai, Gaole; Deng, Wei; Zhang, Xiujuan; Jie, Jiansheng; Zhang, Xiaohong

    2017-10-01

    Organic field-effect transistors (OFETs) based on organic micro-/nanocrystals have been widely reported with charge carrier mobility exceeding 1.0 cm2 V-1 s-1, demonstrating great potential for high-performance, low-cost organic electronic applications. However, fabrication of large-area organic micro-/nanocrystal arrays with consistent crystal growth direction has posed a significant technical challenge. Here, we describe a solution-processed dip-coating technique to grow large-area, aligned 9,10-bis(phenylethynyl) anthracene (BPEA) and 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS-PEN) single-crystalline nanoribbon arrays. The method is scalable to a 5 × 10 cm2 wafer substrate, with around 60% of the wafer surface covered by aligned crystals. The quality of crystals can be easily controlled by tuning the dip-coating speed. Furthermore, OFETs based on well-aligned BPEA and TIPS-PEN single-crystalline nanoribbons were constructed. By optimizing channel lengths and using appropriate metallic electrodes, the BPEA and TIPS-PEN-based OFETs showed hole mobility exceeding 2.0 cm2 V-1 s-1 (average mobility 1.2 cm2 V-1 s-1) and 3.0 cm2 V-1 s-1 (average mobility 2.0 cm2 V-1 s-1), respectively. They both have a high on/off ratio ( I on/ I off) > 109. The performance can well satisfy the requirements for light-emitting diodes driving.

  16. Effect of hoof angle on joint contact area in the equine metacarpophalangeal joint following simulated impact loading ex vivo.

    PubMed

    McCarty, C A; Thomason, J J; Gordon, K; Hurtig, M; Bignell, W

    2015-11-01

    To add to the existing data on impact loading of the metacarpophalangeal (MCP) joint as a precursor to assessing the potential role of impact in joint disease. To examine the effect of impact loading on contact areas of the first phalanx (P1) and proximal sesamoids (PS) with the third metacarpal (McIII) under 3 hoof-strike conditions (toe-first, flat, heel-first). Randomised, repeated controlled experiment using cadaver material. Eight cadaver limbs were subjected to randomised, repeated controlled trials where the hoof was struck by a pendulum impact machine (impact velocity 3.55 m/s) under 3 strike conditions. Data from pressure sensitive film placed over medial and lateral McIII condyles and lateromedially across the dorsal aspect of McIII were quantified: total areas of P1 and PS contact (cm(2) ) at maximum recorded pressure; centroid locations of contact areas relative to the sagittal ridge (cm) and transverse ridge (cm) and dispersion of pixels (cm(4) ) for each McIII condyle (medial/lateral). The effect of the strike conditions on each variable were statistically tested using repeated-measures ANOVA (α = 0.05). Contact area between P1 and McIII condyles fell in well-defined areas bounded by the sagittal and transverse ridge, contact areas from PS were smaller and widely dispersed across McIII palmar border. Ratio of contact area of P1 to PS was 2.83 (P<0001). Hoof strike had no significant effect on contact area (P>0.54) CONCLUSIONS: Contact at impact (primarily from P1 and distally situated on McIII), contrasts with contact areas at midstance from both P1 and PS, symmetrically placed. Under impact, the greatest contact area was on the dorsal aspect of the medial condyle and coincides with the area subjected to the greatest increase in subchondral bone stiffening in joint disease. © 2014 EVJ Ltd.

  17. Chlorhexidine avoids skin bacteria recolonization more than triclosan.

    PubMed

    Macias, Juan H; Alvarez, Mildred F; Arreguin, Virginia; Muñoz, Juan M; Macias, Alejandro E; Alvarez, Jose A

    2016-12-01

    We do not know whether differences exist between the residual effect of 2% chlorhexidine in 70% isopropyl alcohol when compared with 1% triclosan in 70% isopropyl alcohol. Using an analytic, longitudinal, controlled, and comparative experimental trial, with blinded measurements, we recruited healthy, adult volunteers from the University of Guanajuato who completed a stabilization phase of skin microbiota and had no history of skin allergies. Four 25-cm 2 areas of the inner surface of the forearms were designated for study: unscrubbed control for establishing baseline bacterial counts, scrubbed control with tridistilled water, scrubbed with chlorhexidine, and scrubbed with triclosan. Quantitative cultures were taken of all the areas at 0, 3, and 24 hours, using agar plates with neutralizing agents. A total of 135 healthy volunteers were tested. At 24 hours, the unscrubbed control counts were 288 CFU/cm 2 , whereas the scrubbed control counts were 96 CFU/cm 2 ; 24 CFU/cm 2 for chlorhexidine and 96 CFU/cm 2 for triclosan (Kruskal-Wallis χ 2 H = 64.27; P <.001). Chlorhexidine is the best antiseptic option when a prolonged antiseptic effect is needed; for instance, when implanting medical devices or performing surgical procedures. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  18. Do infrared light-emitting diodes have a stimulatory effect on wound healing? From an in-vitro trial to patient treatment

    NASA Astrophysics Data System (ADS)

    Vinck, Elke; Cagnie, B.; Cambier, D.; Cornelissen, M.

    2002-10-01

    Variable effects of different forms of light therapy on wound healing have been reported. This preliminary study covers the efficacy of infrared light emitting diodes (LED) in this domain. Cultured embryonic chicken fibroblasts were treated in a controlled, radomised manner. LED irradiation was performed three consecutive days with a wavelength of 950 nm and a power output of 160 mW, at 0,6 cm distance from the fibroblasts. Each treatment lasted 6 minutes, resulting in a surface energy denstiy of 3,2 J/cm2. The results indicated that LED treatment does not influence fibroblast proliferation at the applied energy density and irradiation frequency (p=0,474). Meanwhile the effects of LED on wound healing in vivo were studied by treating a surgical incision (6 cm) on the lateral side of the right foot in a male patient. The treatment started after 13 days, when initial stitches were being removed. The same parameters as in the in vitro study were used but the treatment was performed five times. The healing could only be evaluated clinically, the irradiated area (2,6 cm) showed a more appropriate contraction, less discoloration and a less hypertrophic scar than the control area (3,4 cm). The used parameters failed to demonstrate any biological effect of LED irradiation in vitro, although the case study on the other hand illustrated a beneficial effect.

  19. Regulation of abdominal adiposity by probiotics (Lactobacillus gasseri SBT2055) in adults with obese tendencies in a randomized controlled trial.

    PubMed

    Kadooka, Y; Sato, M; Imaizumi, K; Ogawa, A; Ikuyama, K; Akai, Y; Okano, M; Kagoshima, M; Tsuchida, T

    2010-06-01

    In spite of the much evidence for the beneficial effects of probiotics, their anti-obesity effects have not been well examined. We evaluated the effects of the probiotic Lactobacillus gasseri SBT2055 (LG2055) on abdominal adiposity, body weight and other body measures in adults with obese tendencies. We conducted a multicenter, double-blind, randomized, placebo-controlled intervention trial. Subjects (n=87) with higher body mass index (BMI) (24.2-30.7 kg/m(2)) and abdominal visceral fat area (81.2-178.5 cm(2)) were randomly assigned to receive either fermented milk (FM) containing LG2055 (active FM; n=43) or FM without LG2055 (control FM; n=44), and were asked to consume 200 g/day of FM for 12 weeks. Abdominal fat area was determined by computed tomography. In the active FM group, abdominal visceral and subcutaneous fat areas significantly (P<0.01) decreased from baseline by an average of 4.6% (mean (confidence interval): -5.8 (-10.0, -1.7) cm(2)) and 3.3% (-7.4 (-11.6, -3.1) cm(2)), respectively. Body weight and other measures also decreased significantly (P<0.001) as follows: body weight, 1.4% (-1.1 (-1.5, -0.7) kg); BMI, 1.5% (-0.4 (-0.5, -0.2) kg/m(2)); waist, 1.8% (-1.7 (-2.1, -1.4) cm); hip, 1.5% (-1.5 (-1.8, -1.1) cm). In the control group, by contrast, none of these parameters decreased significantly. High-molecular weight adiponectin in serum increased significantly (P<0.01) in the active and control groups by 12.7% (0.17 (0.07, 0.26) microg/ml) and 13.6% (0.23 (0.07, 0.38) microg/ml), respectively. The probiotic LG2055 showed lowering effects on abdominal adiposity, body weight and other measures, suggesting its beneficial influence on metabolic disorders.

  20. Effects of breathing variation on gating window internal target volume in respiratory gated radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cai Jing; McLawhorn, Robert; Read, Paul W.

    Purpose: To investigate the effects of breathing variation on gating window internal target volume (ITV{sub GW}) in respiratory gated radiation therapy. Method and Materials: Two-dimensional dynamic MRI (dMRI) of lung motion was acquired in ten volunteers and eight lung cancer patients. Resorted dMRI using 4DCT acquisition method (RedCAM) was generated for selected subjects by simulating the image rebinning process. A dynamic software generated phantom (dSGP) was created by moving a solid circle (to mimic the ''tumor'') with dMRI-determined motion trajectories. The gating window internal target area (ITA{sub GW}, 2D counterpart of ITV{sub GW}) was determined from both RedCAM and dSGP/dMRI.more » Its area (A), major axis (L1), minor axis (L2), and similarity (S) were calculated and compared. Results: In the phantom study of 3 cm tumor, measurements of the ITA{sub GW} from dSGP (A=10.0{+-}1.3 cm{sup 2}, L1=3.8{+-}0.4 cm, and L2=3.3{+-}0.1 cm) are significantly (p<0.001) greater than those from RedCAM (A=8.5{+-}0.7 cm{sup 2}, L1=3.5{+-}0.2 cm, and L2=3.1{+-}0.1 cm). Similarly, the differences are significantly greater (p<0.001) for the 1 cm tumor (A=1.9{+-}0.5 cm{sup 2}, L1=1.9{+-}0.4 cm, and L2=1.3{+-}0.1 cm in dSGP; A=1.3{+-}0.1 cm{sup 2}, L1=1.5{+-}0.2 cm, and L2=1.1{+-}0.1 cm in RedCAM). In patient studies, measurements of the ITA{sub GW} from dMRI (A=15.5{+-}8.2 cm{sup 2}, L1=5.0{+-}1.1 cm, and L2=3.8{+-}1.2 cm) are also significantly greater (p<0.05) than those from RedCAM (A=13.2{+-}8.5 cm{sup 2}, L1=4.3{+-}1.4 cm, and L2=3.7{+-}1.2 cm). Similarities were 0.9{+-}0.1, 0.8{+-}0.1, and 0.8{+-}0.1 in the 3 cm tumor phantom, 1 cm tumor phantom, and patient studies, respectively. Conclusion: ITV{sub GW} can be underestimated by 4DCT due to breathing variations. An additional margin may be needed to account for this potential error in generating a PTV{sub GW}. Cautions need to be taken when generating ITV{sub GW} from 4DCT in respiratory gated radiation therapy, especially for small tumors (<3 cm) with a large motion range (>1 cm).« less

  1. Anthropic influences on the sedimentation rates of lakes situated in different geographic areas.

    PubMed

    Simon, Hedvig; Kelemen, Szabolcs; Begy, Róbert-Csaba

    2017-07-01

    The aim of this study is to determine the effects of natural and anthropic events occurring in the last 30 years in the catchment areas of four Romanian lakes (St. Anna Lake, Red Lake, Vârşolţ Lake and Matiţa Lake) originating from four different geomorphologic areas. A total of eleven sediment cores have been processed for age and sedimentation rate determination using the 210 Pb dating method. Total 210 Pb was measured via alpha spectrometry by 210 Po using PIPS detectors, while supported 210 Pb was measured by 226 Ra using HPGe detectors. Ages and sedimentation rates were calculated using the CRS model. The values of the sedimentation rates have grown multiply in the last three decades: 2.66 times in case of the St. Anna Lake (from 0.06 ± 0.01 g/cm 2 y to 0.16 ± 0.02 g/cm 2 y), up to 6.72 times in case of Red Lake (0.36 ± 0.04 g/cm 2 y to 2.42 ± 0.36 g/cm 2 y), 4.02 times in case of Vârşolţ Lake (04 g/cm 2 y to 1.53 ± 0.18 g/cm 2 y) and up to 16.18 times in case of Matiţa Lake (0.27 ± 0.03 g/cm 2 y to 4.37 ± 0.32). Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Environmental assessment for the Satellite Power System (SPS): studies of honey bees exposed to 2. 45 GHz continuous-wave electromagnetic energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary, N E; Westerdahl, B B

    1980-12-01

    A system for small animal exposure was developed for treating honey bees, Apis mellifera L., in brood and adult stages, with 2.45 GHz continuous wave microwaves at selected power densities and exposure times. Post-treatment brood development was normal and teratological effects were not detected at exposures of 3 to 50 mw/cm/sup 2/ for 30 minutes. Post-treatment survival, longevity, orientation, navigation, and memory of adult bees were also normal after exposures of 3 to 50 mw/cm/sup 2/ for 30 minutes. Post-treatment longevity of confined bees in the laboratory was normal after exposures of 3 to 50 mw/cm/sup 2/ for 24 hours.more » Thermoregulation of brood nest, foraging activity, brood rearing, and social interaction were not affected by chronic exposure to 1 mw/cm/sup 2/ during 28 days. In dynamic behavioral bioassays the frequency of entry and duration of activity of unrestrained, foraging adult bees was identical in microwave-exposed (5 to 40 mw/cm/sup 2/) areas versus control areas.« less

  3. Effect of organic loading rates and proton exchange membrane surface area on the performance of an up-flow cylindrical microbial fuel cell.

    PubMed

    Jana, Partha S; Behera, Manaswini; Ghangrekar, M M

    2012-01-01

    The effect of organic loading rates (OLRs) and proton exchange membrane (PEM) surface area on the performance of microbial fuel cells (MFCs) was evaluated. Three MFCs (MFC-1, MFC-2 and MFC-3) having PEM surface area of 10 cm2, 20 cm2 and 40 cm2, respectively, were used in the study. The MFCs were operated at influent chemical oxygen demand (COD) of 500 mg L(-1) and hydraulic retention time (HRT) of 20 h, 17 h, 13 h and 6 h in experimental Run-1 to Run-4. MFC-3, with highest PEM surface area showed highest power generation throughout the study. The optimum performancewas obtained at HRT of 13 h. In Run-5 and Run-6, the influent COD was increased to 1000 mg L(-1) and 1500 mg L(-1), respectively, maintaining the HRT at 13 h. Maximum volumetric powers of 4.26 W m(-3), 9.41 W m(-3) and 17.24 W m(-3) were obtained in MFC-1, MFC-2 and MFC-3, respectively, in Run-5 under the OLR of 1.84 kg COD m(-3) d(-1). These power values are among the higher values reported in literature; MFCs with higher PEM surface area showed better electricity generation, which clearly demonstrates that proton mass transfer is the main constraint in the MFCs which limits the power output. Combined effect of influent COD and HRT was found on electricity generation.

  4. Effect of systemic morphine on the responses of convergent neurons to noxious heat stimuli applied over graded surface areas.

    PubMed

    Gall, O; Bouhassira, D; Chitour, D; Le Bars, D

    1999-04-01

    Stimulus intensity is a major determinant of the antinociceptive activity of opiates. This study focused on the influence of the spatial characteristics of nociceptive stimuli, on opiate-induced depressions of nociceptive transmission at the level of the spinal cord. Anesthetized rats were prepared to allow extracellular recordings to be made from convergent neurons in the lumbar dorsal horn. The effects of systemic morphine (1 and 10 mg/kg) were compared with those of saline for thermal stimuli of constant intensity, applied to the area of skin surrounding the excitatory receptive field (1.9 cm2) or to a much larger adjacent area (18 cm2). The responses (mean +/- SD) elicited by the 1.9-cm2 stimulus were not modified by 1 mg/kg intravenous morphine, although they were decreased by the 10-mg/kg dose (to 11+/-4% of control values compared with saline; P < 0.05). In contrast, when the 18-cm2 stimulus was applied, 1 mg/kg intravenous morphine produced a paradoxical facilitation of the neuronal responses (159+/-36% of control values; P < 0.05) and 10 mg/kg intravenous morphine resulted in a weaker depression of the responses (to 42+/-24% of control values; P < 0.05) than was observed with the smaller stimulus. Doses of systemic morphine in the analgesic range for rats had dual effects on nociceptive transmission at the level of the spinal cord, depending on the surface area that was stimulated. Such effects are difficult to explain in terms of accepted pharmacodynamic concepts and may reflect an opioid-induced depression of descending inhibitory influences triggered by spatial summation.

  5. Root coverage using porcine collagen matrix with fibroblast growth factor-2: a pilot study in dogs.

    PubMed

    Cha, Jae Kook; Sun, Yoo-Kyung; Lee, Jung-Seok; Choi, Seong-Ho; Jung, Ui-Won

    2017-01-01

    The aim of this study was to evaluate the effect of fibroblast growth factor-2 (FGF-2) in combination with porcine collagen matrix (CM) for coverage of gingival recession defects in dogs. In five male mongrel dogs, labial gingival recession defects were surgically created in the lower-third incisors bilaterally. The defects were randomly assigned to the CM/FGF-2 group (experimental) or the CM-only group (control). Standardized clinical photographs and silicone impressions were taken at 4 and 16 weeks of healing to calculate the remaining recession area. The dogs were euthanized after 16 weeks for histometric analysis. At 4 weeks, the recession area of the CM/FGF-2 group was significantly smaller than that of the CM-only group (2.55 ± 0.66 and 4.92 ± 1.05 mm 2 , respectively, p = 0.023), However, no significant difference was observed at 16 weeks. Histometrically, the amount of newly formed cementum was larger in the CM/FGF-2 group than in the CM-only group at 16 weeks (1.55 ± 0.44 and 0.88 ± 0.51 mm, respectively, p = 0.024). The combination of CM/FGF-2 may enhance the early wound healing and may promote cementum formation to a higher extent compared to the use of CM alone. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. In Vitro Study of Dentin Hypersensitivity Treated by 980-nm Diode Laser.

    PubMed

    Liu, Ying; Gao, Jie; Gao, Yan; Xu, Shuaimei; Zhan, Xueling; Wu, Buling

    2013-01-01

    To investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (DH). Twenty extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into four areas and was irradiated by 980-nm diode laser under different parameters: Group A: control group, 0 J/cm(2); Group B: 2 W/CW (continuous mode), 166 J/cm(2); Group C: 3W/CW, 250 J/cm(2); and Group D: 4W/CW, 333 J/cm(2). Ten additional extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into two areas and was irradiated by 980-nm diode laser: Group E: control group, 0 J/cm(2); and Group F: 2.0 W/CW, 166 J/cm(2). The morphological alterations of the dentin surfaces and odontoblasts were examined with scanning electron microscopy (SEM), and the morphological alterations of the dental pulp tissue irradiated by laser were observed with an upright microscope. The study demonstrated that dentinal tubules can be entirely blocked after irradiation by 980-nm diode laser, regardless of the parameter setting. Diode laser with settings of 2.0 W and 980-nm sealed exposed dentin tubules effectively, and no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. Irradiation with 980-nm diode laser could be effective for routine clinical treatment of DH, and 2.0W/CW (166 J/cm(2)) was a suitable energy parameter due to its rapid sealing of the exposed dentin tubules and its safety to the odontoblasts and pulp tissue.

  7. In Vitro Study of Dentin Hypersensitivity Treated by 980-nm Diode Laser

    PubMed Central

    Liu, Ying; Gao, Jie; Gao, Yan; XU, Shuaimei; Zhan, Xueling; Wu, Buling

    2013-01-01

    Introduction: To investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (DH). Methods: Twenty extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into four areas and was irradiated by 980-nm diode laser under different parameters: Group A: control group, 0 J/cm2; Group B: 2 W/CW (continuous mode), 166 J/cm2; Group C: 3W/CW, 250 J/cm2; and Group D: 4W/CW, 333 J/cm2. Ten additional extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into two areas and was irradiated by 980-nm diode laser: Group E: control group, 0 J/cm2; and Group F: 2.0 W/CW, 166 J/cm2. The morphological alterations of the dentin surfaces and odontoblasts were examined with scanning electron microscopy (SEM), and the morphological alterations of the dental pulp tissue irradiated by laser were observed with an upright microscope. Results: The study demonstrated that dentinal tubules can be entirely blocked after irradiation by 980-nm diode laser, regardless of the parameter setting. Diode laser with settings of 2.0 W and 980-nm sealed exposed dentin tubules effectively, and no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. Conclusions: Irradiation with 980-nm diode laser could be effective for routine clinical treatment of DH, and 2.0W/CW (166 J/cm2) was a suitable energy parameter due to its rapid sealing of the exposed dentin tubules and its safety to the odontoblasts and pulp tissue. PMID:25606318

  8. Right Ventricle before and after Atrial Septal Defect Device Closure.

    PubMed

    Akula, Vidya Sagar; Durgaprasad, Rajasekhar; Velam, Vanajakshamma; Kasala, Latheef; Rodda, Madhavi; Erathi, Harsha Vardhan

    2016-09-01

    Percutaneous atrial septal defect (ASD) device closure is a safe and effective means of reducing or eliminating interatrial shunting. The response of the right heart to device closure is incompletely understood. To evaluate the effects of transcatheter closure of secundum ASD on right ventricle size and function, that is, both systolic and diastolic by transthoracic echocardiography (TTE) over a 6-month period. Seventy-three patients had 73 device implantations. The patients were assessed with echocardiography before and at 1 and 6 months after procedure. Mean age was 26 ± 17 years. Mean ASD size indexed to body surface area (BSA) was 19.1 ± 8.6 mm/m(2) . The device size ranged from 12 to 42 mm. One month after closure, there were statistically significant decreases in right ventricular (RV) basal diameter (3.5 ± 0.7 cm vs. 4.2 ± 0.8 cm), RV/LV end-diastolic diameter ratio (0.9 ± 0.1 vs. 1.2 ± 0.2), left ventricular eccentricity index (LVEI) (1.0 ± 0.1 vs. 1.2 ± 0.2), right atrial (RA) major dimension (4.4 ± 0.8 cm vs. 4.8 ± 1.0 cm), RA end-systolic area (13.2 ± 4.6 cm(2) vs. 18.5 ± 6.7 cm(2) ), tricuspid annular plane systolic excursion (TAPSE) (2.2 ± 1.8 cm vs. 2.8 ± 0.5 cm), tricuspid annular systolic velocity (TASV or S') (13.1 ± 3.0 cm/sec vs. 16.0 ± 2.8 cm/sec), E/A (1.4 ± 0.3 vs. 1.7 ± 0.5), and E/e' (5.9 ± 5.0 vs. 7.2 ± 2.0) in comparison with baseline. Six months after closure, there were statistically significant decreases in RV major dimension (5.9 ± 1.1 cm vs. 6.3 ± 1.0 cm), RV/LV end-diastolic diameter ratio (0.8 ± 0.1 vs. 0.9 ± 0.1), RA major dimension (4.1 ± 0.8 cm vs. 4.4 ± 0.8 cm), and RA end-systolic area (11.4 ± 3.8 cm(2) vs. 13.2 ± 4.6 cm(2) ) in comparison with 1 month post-device closure. After 6 months, there was a statistically insignificant increase in both TASV (13.7 ± 2.8 cm/sec vs. 13.1 ± 3.0 cm/sec) and TAPSE (2.5 ± 1.6 cm/sec vs. 2.2 ± 1.8 cm/sec). There was no significant change in tissue Doppler MPI at baseline, 1 month, and 6 months after closure (0.38 ± 0.19 vs. 0.35 ± 0.15 vs. 0.38 ± 0.13). There was significant decrease in E/e' from baseline to 1 month and 1 month to 6 months after closure (7.2 ± 2.0 vs. 5.9 ± 5.0 vs. 4.7 ± 1.5). RV volumes decreased significantly in the first month after ASD device closure and continued up to 6 months. There was no change in global right ventricular systolic function but a high basal RV systolic function decreased after closure. Some patients had impaired diastolic function before closure of defect, which reversed to normal within 6 months after closure. Diastolic dysfunction in older age-group may be a cause for long duration taken by right heart chambers to regress and deserves further investigation. © 2016, Wiley Periodicals, Inc.

  9. VizieR Online Data Catalog: Soft X-ray standards (Beuermann+, 2006)

    NASA Astrophysics Data System (ADS)

    Beuermann, K.; Burwitz, V.; Rauch, T.

    2006-08-01

    Table A1 contains the area correction functions to the Chandra LETG+HRCS effective areas for the negative and positive dispersion directions, alphaneg, alphapos, and their area-weighted mean alpha as well as the corrected effective areas for a gravity of HZ43A of logg=7.90. Tables A2 and A3 are for logg=7.80 and 8.00, respectively. The corrected area A is obtained as the recommended area of the Chandra November 2004 release (http://cxc.harvard.edu/cal/Letg, LETG/HRC-S Effective Area, updated November 2004), referred to as A0 in the paper, multiplied with the correction function alpha (see Section 4.4.1 of the paper for further explanation). The variation of the correction functions alpha and the corrected areas A between the three tables indicate their systematic errors around the nominal values of Table A1 which are depicted in Fig. 5 of the paper. The columns of Tables A1 to A3 provide the wavelength Lambda ({AA}), alphaneg, alphapos, alpha, Aneg (cm2), Apos (cm2), and A (cm2). The header to each Table contains the parameters of the respective fit. Table A4 contains the best-fit incident soft X-ray spectra of HZ43A, SiriusB, and RXJ1856-37 for a gravity of HZ43A of logg=7.90 as shown in Fig. 6 of the paper (see also Table 3 of the paper). Tables A5 and A6 are for logg=7.80 and 8.00, respectively. The best-fit spectra are based on the most recent version of the Tuebingen Model Atmosphere Package TMAP (Werner et al. 2003, in: Workshop on Stellar Atmosphere Modeling, eds. I. Hubeny, D. Mihalas, K. Werner, ASP Conf. Ser. 288, 31; Rauch & Deetjen 2003, ASP Conf. Ser. 288, 103). The columns of Tables A1 to A3 provide the wavelength Lambda ({AA}) and the photon fluxes of the three stars in photons/cm2/s/{AA}. The header to each Table contains the parameters of the respective fit. (6 data files).

  10. Echocardiography underestimates stroke volume and aortic valve area: implications for patients with small-area low-gradient aortic stenosis.

    PubMed

    Chin, Calvin W L; Khaw, Hwan J; Luo, Elton; Tan, Shuwei; White, Audrey C; Newby, David E; Dweck, Marc R

    2014-09-01

    Discordance between small aortic valve area (AVA; < 1.0 cm(2)) and low mean pressure gradient (MPG; < 40 mm Hg) affects a third of patients with moderate or severe aortic stenosis (AS). We hypothesized that this is largely due to inaccurate echocardiographic measurements of the left ventricular outflow tract area (LVOTarea) and stroke volume alongside inconsistencies in recommended thresholds. One hundred thirty-three patients with mild to severe AS and 33 control individuals underwent comprehensive echocardiography and cardiovascular magnetic resonance imaging (MRI). Stroke volume and LVOTarea were calculated using echocardiography and MRI, and the effects on AVA estimation were assessed. The relationship between AVA and MPG measurements was then modelled with nonlinear regression and consistent thresholds for these parameters calculated. Finally the effect of these modified AVA measurements and novel thresholds on the number of patients with small-area low-gradient AS was investigated. Compared with MRI, echocardiography underestimated LVOTarea (n = 40; -0.7 cm(2); 95% confidence interval [CI], -2.6 to 1.3), stroke volumes (-6.5 mL/m(2); 95% CI, -28.9 to 16.0) and consequently, AVA (-0.23 cm(2); 95% CI, -1.01 to 0.59). Moreover, an AVA of 1.0 cm(2) corresponded to MPG of 24 mm Hg based on echocardiographic measurements and 37 mm Hg after correction with MRI-derived stroke volumes. Based on conventional measures, 56 patients had discordant small-area low-gradient AS. Using MRI-derived stroke volumes and the revised thresholds, a 48% reduction in discordance was observed (n = 29). Echocardiography underestimated LVOTarea, stroke volume, and therefore AVA, compared with MRI. The thresholds based on current guidelines were also inconsistent. In combination, these factors explain > 40% of patients with discordant small-area low-gradient AS. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  11. The immediate effects of deep breathing exercises on atelectasis and oxygenation after cardiac surgery.

    PubMed

    Westerdahl, Elisabeth; Lindmark, Birgitta; Eriksson, Tomas; Hedenstierna, Göran; Tenling, Arne

    2003-12-01

    Objective--To investigate the effects of deep breathing performed on the second postoperative day after coronary artery bypass graft surgery. Design--The immediate effects of 30 deep breaths performed without a mechanical device (n = 21), with a blow bottle device (n = 20) and with an inspiratory resistance-positive expiratory pressure mask (n = 20) were studied. Spiral computed tomography and arterial blood gas analyses were performed immediately before and after the intervention. Results--Deep breathing caused a significant decrease in atelectatic area from 12.3 +/- 7.3% to 10.2 +/- 6.7% (p < 0.0001) of total lung area 1 cm above the diaphragm and from 3.9 +/- 3.5% to 3.3 +/- 3.1% (p < 0.05) 5 cm above the diaphragm. No difference between the breathing techniques was found. The aerated lung area increased by 5% (p < 0.001). The PaO (2) increased by 0.2 kPa (p < 0.05), while PaCO (2) was unchanged in the three groups. Conclusion--A significant decrease of atelectatic area, increase in aerated lung area and a small increase in PaO (2) were found after performance of 30 deep breaths. No difference between the three breathing techniques was found.

  12. The effect of woven roving fiberglass total layers on resin infusion time in vacuum infusion

    NASA Astrophysics Data System (ADS)

    Saputra, A. H.; Ibrahim, R. H.

    2018-04-01

    Composite material consists of reinforcement materials and resin as a matrix. Vacuum infusion isone of composite material manufacturing process. This process is to minimize the air cavity on composite material. The composite material will have good mechanical properties. There is a problem in vacuum infusion related to resin gelling time that must be considered. In this study, the area as well as the reinforcement layers are variated. Unsaturated polyester was used as resin and woven roving fiberglass was used as reinforcement. This study was obtained that resin infusion time data for woven roving, 15x20 cm of size, in two until six layers are 55 seconds to 78 seconds; whereas, the infusion times for 15x25 cm of size,in two until six layers are 119 seconds to 235 seconds; whereas the infusion time for 15x35 cm of size, in two until six layers are 181 seconds to 303 seconds. By data processing, the maximum fiber area that resin still can flow, for 6 layers, is 0,4391 m2 (or 15 cm x 2.92m). Maximum fiber total layers for the specimen with 15x20cm2, 15x25cm2 and 15x35 cm2 of areaare 147, 145 and 125 layers respectively.

  13. The effect of incremental distal gastric myotomy lengths on EGJ distensibility during POEM for achalasia

    PubMed Central

    Teitelbaum, Ezra N.; Sternbach, Joel M.; Khoury, Rym El; Soper, Nathaniel J.; Pandolfino, John E.; Kahrilas, Peter J.; Lin, Zhiyue; Hungness, Eric S.

    2015-01-01

    Background During peroral esophageal myotomy (POEM) for the treatment of achalasia, the optimal distal gastric myotomy length is unknown. In this study we used a functional lumen imaging probe (FLIP) to intraoperatively measure the effect of variable distal myotomy lengths on esophagogastric junction (EGJ) distensibility. Methods EGJ distensibility index (DI) (minimum cross-sectional area divided by intra-bag pressure) was measured with FLIP after each operative step. Each patient's myotomy was performed in four increments from proximal to distal: 1) an esophageal myotomy (from 6cm proximal to the EGJ, to 1cm proximal to it), 2) a myotomy ablating the lower esophageal sphincter (LES) complex (from 1cm proximal to the EGJ, to 1cm distal to it), 3) an initial gastric extension (from 1cm distal to the EGJ, to 2cm distal), and 4) a final gastric extension (from 2cm distal to the EGJ, to 3cm distal). Results Measurements were performed in 16 achalasia patients during POEM. POEM resulted in an overall increase in DI (pre 1.2 vs. post 7.2 mm2/mmHg, p<.001). Initial creation of the submucosal tunnel resulted in a 3-fold increase in DI (1.2 vs. 3.6 mm2/mmHg, p<.001). When the myotomy was then performed in a stepwise fashion from proximal to distal, the initial esophageal myotomy component had no effect on DI. Subsequent myotomy extension across the LES complex resulted in an increase in DI, as did the initial gastric myotomy extension (to 2cm distal to the EGJ). The final gastric myotomy extension (to 3cm distal) had no further effect. Conclusions During POEM, creation of the submucosal tunnel prior to myotomy resulted in a marked improvement in EGJ physiology. Myotomy extension across the LES complex and to 2cm onto the gastric wall resulted in normalization of EGJ distensibility, whereas subsequent extension to 3cm distal to the EGJ did not increase compliance further. PMID:26092005

  14. Efficacy and safety of a new 5% minoxidil formulation in male androgenetic alopecia: A randomized, placebo-controlled, double-blind, noninferiority study.

    PubMed

    Blume-Peytavi, Ulrike; Issiakhem, Zahida; Gautier, Stephanie; Kottner, Jan; Wigger-Alberti, Walter; Fischer, Tobias; Hoffmann, Rolf; Tonner, Françoise; Bouroubi, Athmane; Voisard, Jean-Jacques

    2018-04-16

    Androgenetic alopecia (AGA) is the most common cause of hair loss in men. Topical minoxidil solutions can help to treat AGA but have to be applied continuously to be effective. A new minoxidil formulation with improved cosmetic characteristics (DC0120, Pierre-Fabre Dermatologie) was tested for noninferiority vs a comparator minoxidil product (ALOSTIL ® , Johnson & Johnson) in stimulating hair growth in men with AGA. Two 10 cm 2 areas on the scalp of each subject were randomized to receive DC0120, the comparator, or one of their corresponding vehicles, applied twice per day for 16 weeks. Nonvellus target area hair count (TAHC) was measured within treatment areas at baseline (day 1) and after 8 and 16 weeks by digital phototrichogram. Two hundred and twenty subjects were included and randomized, of which 210 completed the study. The mean change in nonvellus TAHC between baseline and week 16 was +22.0 hairs/cm 2 (95% CI: 18.1; 25.9) in the DC0120 group and +20.5 hairs/cm 2 (95% CI: 16.6; 24.4) in the comparator group. The adjusted mean difference in TAHC changes between the two treatments was +1.5 hairs/cm 2 (95% CI -2.3; 5.2), with the lower 95% confidence interval above the noninferiority threshold of -7 hairs/cm 2 . This indicated that DC0120 was noninferior to the comparator. Both minoxidil treatments also increased nonvellus TAHC compared to vehicle groups at 8 and 16 weeks. No new safety signals were observed. DC0120 was as safe and effective as a similar marketed minoxidil product for stimulating hair growth in men with AGA. © 2018 Wiley Periodicals, Inc.

  15. Dye anchored ZnO nanoparticles: The positive and negative photoluminescence quenching effects

    NASA Astrophysics Data System (ADS)

    Ganesh, T.; Kim, Jong Hoon; Yoon, Seog Joon; Lee, Sangjin; Lee, Wonjoo; Mane, Rajaram S.; Han, Jin Wook; Han, Sung-Hwan

    2009-10-01

    The positive and negative photoluminescence quenching effects in dye [BCMoxo and BCtCM (curcumin-derived molecules)] anchored ZnO nanoparticles (NPs) are investigated using the optical and electronic properties. The photoluminescence, band gap (BCMoxo, 2.2 eV; BCtCM, 2.3 eV), and wettability studies confirm an optical quenching, well-matched electronic structure and relative hydrophobic nature, respectively, in the presence of dicarboxylic anchor groups (BCtCM) on ZnO NPs in contrast to that of keto groups (BCMoxo). Systematic change in UV-visible absorption band edge is noticeable for the BCtCM and BCMoxo-anchored ZnO NPs. The atomic absorption spectroscopy and inductively coupled-mass-spectroscopy analysis quantitatively verifies the amount of BCtCM dye molecules present on ZnO NPs surface area about three times higher than that of BCMoxo dye molecule without anchor groups.

  16. Effect of preweaning nutritional management on yearling weight response in an open-herd selection program.

    PubMed

    Hough, J D; Benyshek, L L

    1988-10-01

    Records on 276 progeny were collected in the final 2 yr (1984 and 1985) of an 8-yr Hereford cattle selection project. Selection was practiced using the top sires from the American Hereford Association's National Cattle Evaluation based on yearling weight expected progeny difference. An unselected control line was maintained to monitor environmental change. One-half of each line was creep-fed during the preweaning period for the last 2 yr to evaluate genotype x environment interactions. Direct response to yearling weight selection averaged 28 +/- 8 kg. Correlated response to selection amounted to .057 +/- .028 kg/d in preweaning ADG, 14 +/- 6 kg in weaning weight, .085 +/- .033 kg/d in postweaning ADG, 4.6 +/- 1.5 cm in yearling hip height and 11.2 +/- 3.0 cm2 in yearling pelvic area. Yearling fat thickness and scrotal circumference were not significantly affected by selection. Significant effects of creep feeding were observed for yearling weight (15 +/- 3 kg), preweaning ADG (.067 +/- .012 kg/d), weaning weight (13 +/- 2 kg), yearling hip height (1.2 +/- .5 cm) and yearling fat thickness (.07 +/- .03 cm). Postweaning ADG, yearling pelvic area and yearling scrotal circumference were not affected by creep feeding. No significant genetic group x creep feeding effects were found for any of the traits analyzed, indicating calves genetically superior for growth did not gain any additional advantage from creep feeding.

  17. Proton exchange membrane and electrode surface areas as factors that affect power generation in microbial fuel cells.

    PubMed

    Oh, Sang-Eun; Logan, Bruce E

    2006-03-01

    Power generation in microbial fuel cells (MFCs) is a function of the surface areas of the proton exchange membrane (PEM) and the cathode relative to that of the anode. To demonstrate this, the sizes of the anode and cathode were varied in two-chambered MFCs having PEMs with three different surface areas (A (PEM)=3.5, 6.2, or 30.6 cm(2)). For a fixed anode and cathode surface area (A (An)=A (Cat)=22.5 cm(2)), the power density normalized to the anode surface area increased with the PEM size in the order 45 mW/m(2) (A (PEM)=3.5 cm(2)), 68 mW/m(2) (A (PEM)=6.2 cm(2)), and 190 mW/m(2) (A (PEM)=30.6 cm(2)). PEM surface area was shown to limit power output when the surface area of the PEM was smaller than that of the electrodes due to an increase in internal resistance. When the relative cross sections of the PEM, anode, and cathode were scaled according to 2A (Cat)=A(PEM)=2A (An), the maximum power densities of the three different MFCs, based on the surface area of the PEM (A (PEM)=3.5, 6.2, or 30.6 cm(2)), were the same (168+/-4.53 mW/m(2)). Increasing the ionic strength and using ferricyanide at the cathode also increased power output.

  18. Evaluation of the effects of sildenafil citrate (viagra) on vertebral artery blood flow in patients with vertebro-basilar insufficiency.

    PubMed

    Bozgeyik, Zulkif; Berilgen, Sait; Ozdemir, Huseyin; Tekatas, Aslan; Ogur, Erkin

    2008-01-01

    To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 +/- 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm(2) to 10.80 cm(2) at 45 minutes and 10.81 cm(2) at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs.

  19. Role of morphologic characteristics of the uterine septum in the prediction and prevention of abnormal healing outcomes after hysteroscopic metroplasty

    PubMed Central

    Ludwin, A.; Ludwin, I.; Pityński, K.; Banas, T.; Jach, R.

    2014-01-01

    STUDY QUESTION Can morphologic measurements (width, length and surface area) of the uterine septum predict healing-dependent abnormal anatomic results [ARs; residual septum (RS) and intrauterine adhesions in other locations (IUA-OLs)] after complete hysteroscopic metroplasty (HM)? SUMMARY ANSWER Significant predictors of ARs are the septal width and, to a lesser extent, septal surface area. WHAT IS KNOWN ALREADY Anatomic results after hysteroscopic metroplasty have very large variation. A RS >1 cm and IUA-OLs can aggravate reproductive outcomes, resulting in the need for reoperation. New criteria for diagnosing a uterine septum according to the European Society of Human Reproduction and Embryology (ESHRE) and European Society for Gynaecological Endoscopy (ESGE) have been suggested (ESHRE-ESGE criteria). Autocross-linked hyaluronic acid gel (autocross-linked polysaccharide) has an antiadhesive effect. STUDY DESIGN, SIZE, DURATION A prospective, observational cohort study was performed with 96 women consecutively enrolled between 2007 and 2012. PARTICIPANTS/MATERIALS, SETTING, METHODS Women who had uterine septum and previous miscarriage or infertility presented for evaluation at a university hospital, private hospital or private medical center were included. Preoperative septal width, length and surface area were determined with three-dimensional sonohysterography. Women were treated by hysteroscopy in a standardized manner with three- or four-dimensional transrectal ultrasound guidance (complete resection). Patients received either no adhesion barrier (49 patients) or adhesion barrier with autocross-linked polysaccharide (47 patients). Anatomic results were assessed with three-dimensional sonohysterography and second-look hysteroscopy. Healing-dependent ARs were reported using both American Society of Reproductive Medicine (ASRM) criterion of RS length >1 cm (ASRM>1 cm criterion) and ESHRE-ESGE criteria. Univariate and multivariate logistic regression were used to identify predictors of RS, IUA-OLs and ARs. MAIN RESULTS AND ROLE OF CHANCE In patients who had no adhesion barrier, ARs were diagnosed in 11 of 49 patients (23%) using the ASRM > 1 cm criterion and in 20 of 49 patients (41%) using the ESHRE-ESGE criteria for RS [odds ratio (OR)ESHRE-ESGE:ASRM, 2.4, P = 0.05]. In the patients who had autocross-linked polysaccharide, ARsASRM > 1 cm were diagnosed in 2 of 47 patients (4%) and ARsESHRE-ESGE in 4 of 47 patients (9%). RSESHRE-ESGE was diagnosed significantly more often than RSASRM > 1 cm 19 of 96 (20%) versus 5 of 96 (5%) in all patients (ORESHRE-ESGE:ASRM > 1 cm = 4.5, P < 0.01). In patients who had no adhesion barrier, logistic regression with ASRM > 1 cm and ESHRE-ESGE criteria showed that the width and surface area were predictors of ARs. Models adjusted by patient group confirmed the significance of width as a predictor of ARsASRM > 1 cm [OR for width, 3.5 (P < 0.01); OR for group, 0.22 (P < 0.01)], width as a predictor of ARsESHRE-ESGE [OR for width, 2.2 (P < 0.01); OR for group, 0.26 (P < 0.01)] and surface area as a predictor of ARsASRM > 1 cm [OR for surface area, 1.5 (P < 0.01)]; OR for group, 0.32 (P < 0.01). In patients who had autocross-linked polysaccharide, these predictors were not significant. Receiver-operating characteristic curves showed cutoff values for ARsASRM > 1 cm (septal width, 3.42 cm; septal surface area, 4.68cm2) and ARsESHRE-ESGE (septal width, 3.42 cm; septal surface area, 3.51cm2). LIMITATIONS AND REASONS FOR CAUTION Patients were enrolled in the adhesion barrier group in a time-dependent, consecutive and non-randomized manner. WIDER IMPLICATIONS OF THE FINDINGS A wide septum and large surface area may be indications for adhesion barrier. The use of autocross-linked polysaccharide reduces the risk of ARs. The ESHRE-ESGE criteria may cause greater frequency of recognition of RS than the ASRM > 1 cm criterion, which could result in more frequent reoperations with use of the ESHRE-ESGE criteria, possibly without any significant effect on reproductive performance. STUDY FUNDING/COMPETING INTEREST(S) This work was supported by Jagiellonian University (grant no. K/ZDS/003821). The authors have no competing interest to declare. PMID:24838703

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    González, M. A. Pagnan, E-mail: miguelangel.pagnan@hotmail.com; Mitsoura, E., E-mail: meleni@uaemex.mx; Oviedo, J.O. Hernández

    Mycosis fungoides is a cutaneous lymphoma that accounts for 2–3% of all lymphomas. Several clinical studies have demonstrated the effectiveness of TSEBT (Total Skin Electron Beam Therapy) in patients with mycosis fungoides. It is important to develop this technique and make it available to a larger number of patients in Mexico. Because large fields for electron TSEBT are required in order to cover the entire body of the patient, beam characterization at conventional treatment distances is not sufficient and a calibration distance of 500cm or higher is required. Materials and methods: Calibration of radiochromic Gafchromic® EBT2 film (RCF) for electronsmore » was performed in a solid water phantom (Scanditronix Wellhöfer) at a depth of 1.4cm and a Source Axis Distance (SAD) of 100cm. A polynomial fit was applied to the calibration curve, in order to obtain the equation relating dose response with optical density. The spatial distribution is obtained in terms of percentage of the dose, placing 3×3cm samples of RCF on the acrylic screen, which is placed in front of the patient in order to obtain maximum absorbed dose on the skin, covering an area of 200×100cm{sup 2}. The Percentage Depth Dose (PDD) curve was obtained placing RCF samples at depths of 0, 1, 1.2, 1.4, 1.5, 2, 3, 4, 5, 6, 7, 8 and 9cm in the solid water phantom, irradiated with an ELEKTA SINERGY Linear Accelerator electron beam, with an energy of 6 MeV, at a Source Skin Distance (SSD) of 500cm, with 1000MU = 100Gy, with a cone of 40×40cm and gantry angle of 90°. The RCFs were scanned on a flatbed scanner (EPSON EXPRESSION 10000 XL) and the images were processed with the ImageJ program using a region of interest (ROI) of 1×1cm{sup 2}. Results: The relative spatial dose distribution and the percentage depth dose for a SSD of 500±0.5cm, over an area of 200×100cm{sup 2} was obtained, resulting to an effective maximum dose depth (Z{sub ref}) for electrons of 1.4±0.05cm. Using the same experimental data, horizontal and vertical beam profiles were also graphed, showing a horizontal symmetry of ±035%, horizontal flatness of ±3.62%, vertical symmetry of ±2.1% and vertical flatness of ±14.2%. Conclusions: The electron beam was characterized and the data obtained were useful to determine the spatial dose distribution to a SSD of 500±0.5cm, in an area of 200×100cm{sup 2}. Dose profiles were obtained both horizontally and vertically, thus allowing to assess electron beam symmetry and flatness. PDD analysis up to a depth of 9±0.05cm, has made possible to establish the depth of electron penetration, assuring an only skin irradiation treatment.« less

  1. Effect of organic matter and roots in soil respiration in a Mediterranean riparian areas in Central Spain

    NASA Astrophysics Data System (ADS)

    Gonzalez-Garrido, Laura; Delgado, Juan Antonio; Martinez, Teodora

    2010-05-01

    Soil respiration is one of the largest carbon flux components within terrestrial ecosystems, and small changes in the magnitude of soil respiration could have a large effect on the concentration of CO2 in the atmosphere. The main objective is evaluating the factors controlling soil respiration on the global carbon cycle in riparian areas of Henares River. We evaluated total soil respiration as it was affected by soil temperature, soil moisture, root respiration and organic matter in four areas differing in vegetation cover. We specifically assessed the contribution of soil organic matter and fine root biomass (≤1 mm.) in soil carbon dioxide flux. The study area is located on the riverbanks of Henares River where it passes through the municipal term of Alcala de Henares (Madrid) in Central Spain. Measurements were performed in spring and autumn of 2009. The study was conducted on four different types of riparian vegetation: natural Mediterranean riparian forest, reforestation of 1994, reforestation of 1999 and riparian grassland without trees. In each area of study 3, 25x25 m, plots were delimited and within each plot three sampling units of 50x50 cm were selected at random. The temperature of the ground was taken during the measures from respiration using a Multi-thermometer (-50°C - +300°C) at 5 cm depth. The moisture content of the ground was measured at 5 cm of depth with a HH2 Moisture meter (Delta Devices, Cambridge, UK). The measures of respiration of the ground were realised in field by means of LCI portable (LC pro ADC Bioscientific, Ltd. UK) connected to a ground respiration camera. We introduced the camera 3 cm into the soil just after eliminating the vegetation grass of the surface of measurement cutting carefully the aerial part, without damaging the roots. Soil CO2 flux measurements were registered after stabilization. Immediately after CO2 measurements, we obtained soil samples by means of a drill of 2.18 cm of diameter taking samples to 10 cm and 20 cm depth. Soil samples were dried to the air with the aim of preserving the roots the sample contained. They were extracted manually by means of very fine tweezers. We separate roots by diameter (Fine roots ≤ 1mm; rest of roots > 1mm) and dead from alive using texture and colour as clues. Finally the dry weight of roots was taking with a precision balance +-0.0001. Soil organic matter to 10 and 20 cm of depth were measure in laboratory using the method of Walkley and Black (1934). Differences in Soil CO2 flux, organic matter, fine root biomass, temperature and moisture between areas were analyzed using one-way ANOVAs. Our results suggest that fine root biomass present a larger impact than soil organic matter in soil CO2 flux values. Natural riparian forest presented higher values of soil CO2 flux than the rest of areas even when differences in root biomass and soil organic matter were controlled. Between the grassy area and both reforestations there were no differences in soil CO2 flux. In addition, we found that soil CO2 flux in our study area was more affected by soil temperature than by moisture, which could be relevant in the interpretation of the possible effects of global change. Key words: riparian forest, fine roots, carbon cycle, soil CO2 flux, root respiration. Acknowledgements: Research projects, n°FP08-AG02 IMIDRA and RTA 2006-00101-00-00 INIA and predoctoral scholarship FPI-INIA.

  2. Does pelvicaliceal system anatomy affect success of percutaneous nephrolithotomy?

    PubMed

    Binbay, Murat; Akman, Tolga; Ozgor, Faruk; Yazici, Ozgur; Sari, Erhan; Erbin, Akif; Kezer, Cem; Sarilar, Omer; Berberoglu, Yalcın; Muslumanoglu, Ahmet Yaser

    2011-10-01

    To investigate the effect of the pelvicaliceal system (PCS) anatomy on the percutaneous nephrolithotomy (PCNL) success rate. Although the caliceal anatomy is effective for stone clearance after shock wave lithotripsy and retrograde intrarenal lithotripsy, the effect of the caliceal anatomy after PCNL has not been evaluated to date. A total of 498 patients who had undergone PCNL and preoperative intravenous urography were enrolled in our study. Kidney-related anatomic factors, such as the PCS surface area and type, degree of hydronephrosis, infundibulopelvic angle, upper-lower calix angle, infundibular length, and infundibular width were calculated using intravenous urography. The association between the PCNL success rate and kidney-related anatomic factors was retrospectively analyzed using chi-square tests, Fisher's exact test, Mann-Whitney U test, and forward stepwise regression analysis. A success rate of 78.1% was achieved. No difference was seen the success rates among the PCS types. The mean PCS surface area was 20.1 ± 9.7 cm(2) in patients with successful outcomes and 24.5 ± 10.2 cm(2) in patients with remaining stones (P = .001). The mean infundibulopelvic angle, upper-lower calix angle, infundibular length, and infundibular width were similar in both groups. Multivariate binary logistic regression analysis showed that stone configuration and PCS surface area were independent factors affecting the PCNL success rates. The results of our study have shown that the PCS surface area is the only anatomic factor that affects the PCNL success rate and patients with a PCS surface area <20.5 cm(2) have greater PCNL success. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Chlorhexidine droplet splash from a skin preparation gallipot: effect of height of pouring.

    PubMed

    Evans, L; Cunningham, M; Tilakaratna, P

    2013-12-01

    Chlorhexidine contamination of equipment used in central neuraxial anaesthesia has been implicated in causing adhesive arachnoiditis. We measured the extent of chlorhexidine splash during pouring into a gallipot (antiseptic skin preparation container) from heights of 5 cm, 10 cm, 15 cm and 20 cm. Twenty experiments were performed at each height. Measurements made up to a horizontal distance of 40 cm radius from the gallipot showed a median (IQR [range]) maximum spread of splash droplets ≥ 2 mm diameter of 26.2 (10.2-36.4 [0-40]) cm. The 40-cm radius measurement area was divided into 5-cm-wide zones to assess spread. At pouring heights of 15 cm and 20 cm, all zones were contaminated. These results demonstrate that pouring chlorhexidine into a gallipot generates significant splash, and we recommend that this should be avoided near equipment used for neuraxial anaesthesia. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  4. Highly Efficient and Uniform 1 cm2 Perovskite Solar Cells with an Electrochemically Deposited NiOx Hole-Extraction Layer.

    PubMed

    Park, Ik Jae; Kang, Gyeongho; Park, Min Ah; Kim, Ju Seong; Seo, Se Won; Kim, Dong Hoe; Zhu, Kai; Park, Taiho; Kim, Jin Young

    2017-06-22

    Given that the highest certified conversion efficiency of the organic-inorganic perovskite solar cell (PSC) already exceeds 22 %, which is even higher than that of the polycrystalline silicon solar cell, the significance of new scalable processes that can be utilized for preparing large-area devices and their commercialization is rapidly increasing. From this perspective, the electrodeposition method is one of the most suitable processes for preparing large-area devices because it is an already commercialized process with proven controllability and scalability. Here, a highly uniform NiO x layer prepared by electrochemical deposition is reported as an efficient hole-extraction layer of a p-i-n-type planar PSC with a large active area of >1 cm 2 . It is demonstrated that the increased surface roughness of the NiO x layer, achieved by controlling the deposition current density, facilitates the hole extraction at the interface between perovskite and NiO x , and thus increases the fill factor and the conversion efficiency. The electrochemically deposited NiO x layer also exhibits extremely uniform thickness and morphology, leading to highly efficient and uniform large-area PSCs. As a result, the p-i-n-type planar PSC with an area of 1.084 cm 2 exhibits a stable conversion efficiency of 17.0 % (19.2 % for 0.1 cm 2 ) without showing hysteresis effects. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Highly Efficient and Uniform 1 cm 2 Perovskite Solar Cells with an Electrochemically Deposited NiO x Hole-Extraction Layer

    DOE PAGES

    Park, Ik Jae; Kang, Gyeongho; Park, Min Ah; ...

    2017-05-10

    Here, given that the highest certified conversion efficiency of the organic-inorganic perovskite solar cell (PSC) already exceeds 22%, which is even higher than that of the polycrystalline silicon solar cell, the significance of new scalable processes that can be utilized for preparing large-area devices and their commercialization is rapidly increasing. From this perspective, the electrodeposition method is one of the most suitable processes for preparing large-area devices because it is an already commercialized process with proven controllability and scalability. Here, a highly uniform NiO x layer prepared by electrochemical deposition is reported as an efficient hole-extraction layer of a p-i-n-typemore » planar PSC with a large active area of >1 cm 2. It is demonstrated that the increased surface roughness of the NiO x layer, achieved by controlling the deposition current density, facilitates the hole extraction at the interface between perovskite and NiO x, and thus increases the fill factor and the conversion efficiency. The electrochemically deposited NiO x layer also exhibits extremely uniform thickness and morphology, leading to highly efficient and uniform large-area PSCs. As a result, the p-i-n-type planar PSC with an area of 1.084 cm 2 exhibits a stable conversion efficiency of 17.0% (19.2% for 0.1 cm 2) without showing hysteresis effects.« less

  6. Optimization of active cell area on the dye-sensitized solar cell efficiency

    NASA Astrophysics Data System (ADS)

    Putri, A. W.; Nurosyid, F.; Supriyanto, Agus

    2017-11-01

    This study is aimed to obtain optimal active area producing high efficiency of DSSC module. The DSSC structure is constructed of TiO2 as working electrode, dye as photosensitizer, platinum as counter electrode, and electrolyte as electron transfer media. TiO2 paste was deposited on Fluorine-doped Tin Oxide (FTO) by screen printing method. Meanwhile, platinum was also coated on FTO via brush painting method. Keithley I-V meter was performed to characterize DSSC electrical property. The active area of each cell was varied of 4.5 cm2, 9 cm2, and 13.5 cm2. Each cell was assembled into a module using an external series connection of Z type. The module was consisted of 12 cells, 6 cells, and 4 cells with module active area of 54 cm2. The optimal active area of DSSC cell is 4.5 cm2 resulting 0.4149% efficiency. In addition, the highest efficiency of DSSC module is 0.2234% acquired by 6 cells assembling.

  7. Helium-induced hardening effect in polycrystalline tungsten

    NASA Astrophysics Data System (ADS)

    Kong, Fanhang; Qu, Miao; Yan, Sha; Zhang, Ailin; Peng, Shixiang; Xue, Jianming; Wang, Yugang

    2017-09-01

    In this paper, helium induced hardening effect of tungsten was investigated. 50 keV He2+ ions at fluences vary from 5 × 1015 cm-2 to 5 × 1017 cm-2 were implanted into polycrystalline tungsten at RT to create helium bubble-rich layers near the surface. The microstructure and mechanical properties of the irradiated specimens were studied by TEM and nano-indentor. Helium bubble rich layers are formed in near surface region, and the layers become thicker with the rise of fluences. Helium bubbles in the area of helium concentration peak are found to grow up, while the bubble density is almost unchanged. Obvious hardening effect is induced by helium implantation in tungsten. Micro hardness increases rapidly with the fluence firstly, and more slowly when the fluence is above 5 × 1016 cm-2. The hardening effect of tungsten can be attributed to helium bubbles, which is found to be in agreement with the Bacon-Orowan stress formula. The growing diameter is the major factor rather than helium bubbles density (voids distance) in the process of helium implantation at fluences below 5 × 1017 cm-2.

  8. 3D MnO2-graphene composites with large areal capacitance for high-performance asymmetric supercapacitors

    NASA Astrophysics Data System (ADS)

    Zhai, Teng; Wang, Fuxin; Yu, Minghao; Xie, Shilei; Liang, Chaolun; Li, Cheng; Xiao, Fangming; Tang, Renheng; Wu, Qixiu; Lu, Xihong; Tong, Yexiang

    2013-07-01

    In this paper, we reported an effective and simple strategy to prepare large areal mass loading of MnO2 on porous graphene gel/Ni foam (denoted as MnO2/G-gel/NF) for supercapacitors (SCs). The MnO2/G-gel/NF (MnO2 mass: 13.6 mg cm-2) delivered a large areal capacitance of 3.18 F cm-2 (234.2 F g-1) and good rate capability. The prominent electrochemical properties of MnO2/G-gel/NF are attributed to the enhanced conductivities and improved accessible area for ions in electrolytes. Moreover, an asymmetric supercapacitor (ASC) based on MnO2/G-gel/NF (MnO2 mass: 6.1 mg cm-2) as the positive electrode and G-gel/NF as the negative electrode achieved a remarkable energy density of 0.72 mW h cm-3. Additionally, the fabricated ASC device also exhibited excellent cycling stability, with less than 1.5% decay after 10 000 cycles. The ability to effectively develop SC electrodes with high mass loading should open up new opportunities for SCs with high areal capacitance and high energy density.In this paper, we reported an effective and simple strategy to prepare large areal mass loading of MnO2 on porous graphene gel/Ni foam (denoted as MnO2/G-gel/NF) for supercapacitors (SCs). The MnO2/G-gel/NF (MnO2 mass: 13.6 mg cm-2) delivered a large areal capacitance of 3.18 F cm-2 (234.2 F g-1) and good rate capability. The prominent electrochemical properties of MnO2/G-gel/NF are attributed to the enhanced conductivities and improved accessible area for ions in electrolytes. Moreover, an asymmetric supercapacitor (ASC) based on MnO2/G-gel/NF (MnO2 mass: 6.1 mg cm-2) as the positive electrode and G-gel/NF as the negative electrode achieved a remarkable energy density of 0.72 mW h cm-3. Additionally, the fabricated ASC device also exhibited excellent cycling stability, with less than 1.5% decay after 10 000 cycles. The ability to effectively develop SC electrodes with high mass loading should open up new opportunities for SCs with high areal capacitance and high energy density. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr01589k

  9. Cracking and Exfoliation of TiO2 Film Irradiated with Excimer Laser

    NASA Astrophysics Data System (ADS)

    Qian, H. X.; Zhou, W.; Zheng, H. Y.

    TiO2 film deposited on glass was irradiated in air with single-shot KrF excimer laser pulse. The surface roughened as the result of the laser ablation. It is further noted that single-pulse irradiation with fluence ranging from 400 to 1200 mJ/cm2 gave rise to protrusion of the irradiated surface above the original surface, which is in contrast to usual expectation that irradiated surface is below the unirradiated surface. The surface protrusion is mainly attributed to the effect of surface tension. At the laser fluence of 1000 mJ/cm2, cracks were formed in the irradiated area and severe film exfoliation was observed at the periphery of the irradiated area due to the release of internal stress. With higher laser fluence above 1000 mJ/cm2, patches of film were observed to peel off within the irradiated areas. Hydrodynamic ablation is proposed to account for film exfoliation. The observed phenomenon is useful for further understanding how TiO2 film reacts to strong UV laser irradiation.

  10. Simulation of 1.5-mm-thick and 15-cm-diameter gated silicon drift X-ray detector operated with a single high-voltage source

    NASA Astrophysics Data System (ADS)

    Matsuura, Hideharu

    2015-04-01

    High-resolution silicon X-ray detectors with a large active area are required for effectively detecting traces of hazardous elements in food and soil through the measurement of the energies and counts of X-ray fluorescence photons radially emitted from these elements. The thicknesses and areas of commercial silicon drift detectors (SDDs) are up to 0.5 mm and 1.5 cm2, respectively. We describe 1.5-mm-thick gated SDDs (GSDDs) that can detect photons with energies up to 50 keV. We simulated the electric potential distributions in GSDDs with a Si thickness of 1.5 mm and areas from 0.18 to 168 cm2 at a single high reverse bias. The area of a GSDD could be enlarged simply by increasing all the gate widths by the same multiple, and the capacitance of the GSDD remained small and its X-ray count rate remained high.

  11. [Effects of light intensity on Quercus liaotungensis seed germination and seedling growth].

    PubMed

    Yan, Xing-fu; Wang, Jian-li; Zhou, Li-biao

    2011-07-01

    This paper studied the effects of different shading (55.4%, 18.9%, 5.5%, 2.2%, 0.5% , and 0.3% natural sunlight) on the seed germination and seedling growth of Quercus liaotungensis. The seed germination rate and germination index were the highest (72.5% and 0.22, respectively) at 55.4% natural sunlight, declined with decreasing light intensity, and were the lowest (42.5% and 0.11, respectively) at 0.3% natural sunlight. Strong light had definite delaying effect on the germination. The index of germination vigor increased with decreasing light intensity, being the maximum at 0.5% natural sunlight. The delay of seed germination under strong light could be the selective tradeoff on varied seed fates. Strong light benefited the basal stem diameter and root system growth and dry mass accumulation of Q. liaotunensis seedling, but resulted in the minimum seedlings height (6.06 cm). Greater morphological plasticity was observed for the seedlings under different shading, which lent support to the higher adaptability of the seedlings to light environment. For example, the specific leaf area, specific shoot length, specific root length, and chlorophyll b and total chlorophyll contents were the maximum at 0.5% natural sunlight, being 142.57 cm2 x g(-1), 156.86 cm x g(-1), 271.87 cm x g(-1), 0.07 g x cm(-2), and 0.24 g x cm(-2), respectively, and the minimum at 55.4% natural sunlight, being 44.89 cm2 x g(-1), 52.84 cm x g(-1), 101.98 cm x g(-1), 0.04 g x cm(-2), and 0.15 g x cm(-2), respectively. The variation of the root/shoot ratio of Q. liaotungensis seedlings under different shading could be the effects of the combination of light intensity and water availability.

  12. Effects of the administration of 2,3-butanedione monoxime during conventional cardiopulmonary resuscitation on ischaemic contracture and resuscitability in a pig model of out-of-hospital cardiac arrest.

    PubMed

    Lee, Byung Kook; Jeung, Kyung Woon; Choi, Sung Soo; Park, Sang Wook; Yun, Seong Woo; Lee, Sung Min; Kim, Nan Yeol; Heo, Tag; Min, Yong Il

    2015-02-01

    Ischaemic contracture compromises the haemodynamic effectiveness of cardiopulmonary resuscitation and resuscitability. 2,3-Butanedione monoxime (BDM) reduced ischaemic contracture by inhibiting actin-myosin crossbridge formation in an isolated heart model. We investigated the effects of BDM on ischaemic contracture and resuscitation outcomes in a pig model of out-of-hospital cardiac arrest (OHCA). After 15min of untreated ventricular fibrillation, followed by 8min of basic life support, 16 pigs were randomised to receive either 2mlkg(-1) of BDM solution (25gl(-1)) or 2mlkg(-1) of saline during advanced cardiac life support (ACLS). During the ACLS, the control group showed an increase in left ventricular (LV) wall thickness from 10.0mm (10.0-10.8) to 13.0mm (13.0-13.0) and a decrease in LV chamber area from 8.13cm(2) (7.59-9.29) to 7.47cm(2) (5.84-8.43). In contrast, the BDM group showed a decrease in the LV wall thickness from 10mm (9.0-10.8) to 8.5mm (7.0-9.8) and an increase in the LV chamber area from 9.86cm(2) (7.22-12.39) to 12.15 cm(2) (8.02-14.40). Mixed model analyses of the LV wall thickness and LV chamber area revealed significant group effects and group-time interactions. Spontaneous circulation was restored in four (50%) animals in the control group and in eight (100%) animals in the BDM group (p=0.077). All the resuscitated animals survived during an intensive care period of 4h. BDM administered during cardiopulmonary resuscitation reversed ischaemic contracture in a pig model of OHCA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Comparison of peak flow velocity through the left ventricular outflow tract and effective orifice area indexed to body surface area in Golden Retriever puppies to predict development of subaortic stenosis in adult dogs.

    PubMed

    Javard, Romain; Bélanger, Marie-Claude; Côté, Etienne; Beauchamp, Guy; Pibarot, Philippe

    2014-12-15

    To evaluate the usefulness of Doppler-derived peak flow velocity through the left ventricular outflow tract (LVOT Vmax) and effective orifice area indexed to body surface area (EOAi) in puppies to predict development of subaortic stenosis (SAS) in the same dogs as adults. Prospective, longitudinal, observational study. 38 Golden Retrievers. Cardiac auscultation and echocardiography were performed on 2- to 6-month-old puppies, then repeated at 12 to 18 months. Subaortic stenosis was diagnosed when LVOT Vmax was ≥ 2.3 m/s in adult dogs with left basilar systolic murmurs. All puppies with EOAi < 1.46 cm(2)/m(2) had SAS as adults. All adults with EOAi < 1.29 cm(2)/m(2) had SAS. An LVOT Vmax > 2.3 m/s in puppyhood was 63% sensitive and 100% specific for SAS in adulthood. In puppies, LVOT Vmax was more strongly associated with a future diagnosis of SAS (area under the curve [AUC], 0.89) than was EOAi (AUC, 0.80). In puppies, the combination of LVOT Vmax and EOAi yielded slightly higher sensitivity (69%) and specificity (100%) for adult SAS than did LVOT Vmax alone. In unaffected and affected dogs, LVOT Vmax increased significantly from puppyhood to adulthood but EOAi did not. In Golden Retriever puppies, LVOT Vmax > 2.3 m/s and EOAi < 1.46 cm(2)/m(2) were both associated with a diagnosis of SAS at adulthood. The combination of these 2 criteria may result in higher sensitivity for SAS screening. Unlike LVOT Vmax, EOAi did not change during growth in either unaffected Golden Retrievers or those with SAS.

  14. [Excimer laser therapy of alopecia areata--side-by-side evaluation of a representative area].

    PubMed

    Raulin, Christian; Gündogan, Cüneyt; Greve, Bärbel; Gebert, Susanne

    2005-07-01

    We report for the first time on hair regrowth in alopecia areata of the scalp achieved with the 308-nm xenon-chloride excimer laser in a prospective side-by-side trial. The alopecia areata had shown progression over a period of three years, and various treatments had not been effective. Out of a number of affected areas, one representative lesion was chosen; one half of it was treated, the other half remained untreated. After 27 sessions (200 - 4000 mJ/cm2, cumulative dose 52.6 J/cm2) over 3 months, only the treated area showed hair growth; which suggests that this was most probably not a spontaneous remission.

  15. Effect of therapeutic ultrasound intensity on subcutaneous tissue temperature and ulnar nerve conduction velocity.

    PubMed

    Kramer, J F

    1985-02-01

    Twenty subjects completed 5 min. periods of sonation, at each of six US intensities, over the ulnar nerve in the proximal forearm. All posttreatment NCV's differed significantly from the respective pretreatment velocities. The immediate posttreatment NCV associated with placebo US was significantly (p less than 0.01) less than that observed immediately pretreatment (2.81 m/s), while the five clinical US intensities produced significantly increased immediate posttreatment velocities: 0.5 w/cm2 (2.23 m/s) at (p less than 0.05), and 1.0 w/cm2 (2.78 m/s), 1.5 w/cm2 (3.15 m/s), 2.0 w/cm2 (4.47 m/s) and 2.5 w/cm2 (2.97 m/s) at (p less than 0.01). The posttreatment velocities associated with the five clinical intensities were all significantly greater (p less than 0.01) than that associated with placebo US. Subcutaneous tissue temperatures were directly related to the intensity of US. Not until US intensity had reached 1.5 w/cm2 did the heating effect of US negate the cooling effect of the US transmission gel, to produce significantly increased subcutaneous tissue temperatures after 5 min. sonation. The decreased ulnar motor NCV's associated with placebo US are attributed to the cooling effect of the US transmission gel. The increased ulnar motor NCV's associated with the clinical intensities of US are attributed to the deep heating effect of US. The breakdown of this linear relationship at 2.5 w/cm2 intensity suggests that at this point heating on the nerve and/or the mechanical effects of US were of sufficient magnitude so as to limit the increase in conduction velocity. Sonation over an area of approximately 4.5 times the soundhead for 5 min., along the proximal forearm, at clinical intensities did not have a bipositive effect on motor NCV.

  16. Functional mitral stenosis after surgical annuloplasty for ischemic mitral regurgitation: Importance of subvalvular tethering in the mechanism and dynamic deterioration during exertion

    PubMed Central

    Kubota, Kayoko; Otsuji, Yutaka; Ueno, Tetsuya; Koriyama, Chihaya; Levine, Robert A.; Sakata, Ryuzo; Tei, Chuwa

    2010-01-01

    Objective Diastolic subvalvular mitral leaflet tethering by left ventricular remodeling that restricts leaflet opening in the presence of annular size reduction by surgery for ischemic mitral regurgitation potentially causes functional mitral stenosis in the absence of organic leaflet lesions. Exercise, known to worsen systolic tethering and ischemic mitral regurgitation, might also dynamically exacerbate such mitral stenosis by increasing tethering. This study evaluates the mechanism and response of such mitral stenosis to exercise. Methods We measured the diastolic mitral valve area, annular area, and peak and mean transmitral pressure gradient by echocardiography in 20 healthy individuals and 31 patients who underwent surgical annuloplasty for ischemic mitral regurgitation. Results Although the mitral valve area and annular area did not significantly differ in healthy individuals (4.7 ± 0.6 cm2 vs 5.2 ± 0.6 cm2, not significant), mitral valve area was significantly smaller than the annular area in patients after annuloplasty (1.6 ± 0.2 cm2 vs 3.3 ± 0.5 cm2, P < .01). The mitral valve area was less than 1.5 cm2 only after the surgery (P < .01) and was significantly correlated with restricted leaflet opening (r2 = 0.74, P <.001), left ventricular dilatation (r2 = 0.17, P <.05), and New York Heart Association functional class (P <. 05). Exercise stress echocardiography of 12 patients demonstrated dynamic worsening in functional mitral stenosis (mitral valve area: 2.0 ± 0.5 cm2 to 1.4 ± 0.2 cm2, P < .01; mean pressure gradient: 1.5 ± 0.9 mm Hg to 6.0 ± 2.2 mm Hg, P < .01). Conclusions Persistent subvalvular leaflet tethering in the presence of annular size reduction by surgery in ischemic mitral regurgitation frequently causes functional mitral stenosis at the leaflet tip level, which is related to heart failure symptoms and can be dynamic with significant exercise-induced worsening. PMID:20122701

  17. Semi-transparent photovoltaic glazing based on electrodeposited CIGS solar cells on patterned molybdenum/glass substrates

    NASA Astrophysics Data System (ADS)

    Sidali, Tarik; Bou, Adrien; Coutancier, Damien; Chassaing, Elisabeth; Theys, Bertrand; Barakel, Damien; Garuz, Richard; Thoulon, Pierre-Yves; Lincot, Daniel

    2018-03-01

    In this paper, a new way of preparing semi-transparent solar cells using Cu(In1-xGax)Se2 (CIGS) chalcopyrite semiconductors as absorbers for BIPV applications is presented. The key to the elaboration process consists in the co-electrodeposition of Cu-In-Ga mixed oxides on submillimetric hole-patterned molybdenum substrate, followed by thermal reduction to metallic alloys and selenisation. This method has the advantage of being a selective deposition technique where the thin film growth is carried out only on Mo covered areas. Thus, after annealing, the transparency of the sample is always preserved, allowing light to pass through the device. A complete device (5 × 5 cm2) with 535 μm diameter holes and total glass aperture of around 35% shows an open circuit voltage (VOC) of 400 mV. Locally, the I-V curves reveal a maximum efficiency of 7.7%, VOC of 460 mV, JSC of 24 mA.cm-2 in an area of 0.1 cm2 with 35% aperture. This efficiency on the semi-transparent area is equivalent to a record efficiency of 11.9% by taking into account only the effective area.

  18. Simulation of strong ground motion parameters of the 1 June 2013 Gulf of Suez earthquake, Egypt

    NASA Astrophysics Data System (ADS)

    Toni, Mostafa

    2017-06-01

    This article aims to simulate the ground motion parameters of the moderate magnitude (ML 5.1) June 1, 2013 Gulf of Suez earthquake, which represents the largest instrumental earthquake to be recorded in the middle part of the Gulf of Suez up to now. This event was felt in all cities located on both sides of the Gulf of Suez, with minor damage to property near the epicenter; however, no casualties were observed. The stochastic technique with the site-dependent spectral model is used to simulate the strong ground motion parameters of this earthquake in the cities located at the western side of the Gulf of Suez and north Red Sea namely: Suez, Ain Sokhna, Zafarana, Ras Gharib, and Hurghada. The presence of many tourist resorts and the increase in land use planning in the considered cities represent the motivation of the current study. The simulated parameters comprise the Peak Ground Acceleration (PGA), Peak Ground Velocity (PGV), and Peak Ground Displacement (PGD), in addition to Pseudo Spectral Acceleration (PSA). The model developed for ground motion simulation is validated by using the recordings of three accelerographs installed around the epicenter of the investigated earthquake. Depending on the site effect that has been determined in the investigated areas by using geotechnical data (e.g., shear wave velocities and microtremor recordings), the investigated areas are classified into two zones (A and B). Zone A is characterized by higher site amplification than Zone B. The ground motion parameters are simulated at each zone in the considered areas. The results reveal that the highest values of PGA, PGV, and PGD are observed at Ras Gharib city (epicentral distance ∼ 11 km) as 67 cm/s2, 2.53 cm/s, and 0.45 cm respectively for Zone A, and as 26.5 cm/s2, 1.0 cm/s, and 0.2 cm respectively for Zone B, while the lowest values of PGA, PGV, and PGD are observed at Suez city (epicentral distance ∼ 190 km) as 3.0 cm/s2, 0.2 cm/s, and 0.05 cm/s respectively for Zone A, and as 1.3 cm/s2, 0.1 cm/s, and 0.024 cm respectively for Zone B. Also the highest PSA values are observed in Ras Gharib city as 200 cm/s2 and 78 cm/s2 for Zone A and Zone B respectively, while the lowest PSA values are observed in Suez city as 7 cm/s2 and 3 cm/s2 for Zone A and Zone B respectively. These results show a good agreement with the earthquake magnitude, epicentral distances, and site characterizations as well.

  19. Stability Analysis of Active Landslide Region in Gerze (Sinop), NW Turkey

    NASA Astrophysics Data System (ADS)

    Çellek, S.; Bulut, F.

    2009-04-01

    Landslides occurring in Turkey causes loss of life and property like many countries of the world. In Turkey, especially Black sea region, landslides are investigated in scale of village, province and city. In this study, Gerze town of Sinop located in Western Black sea was chosen as study area. The study area has some sensitive regions to landslides because of geology, geomorphology and climate conditions. Landslides occur due to heavy rains happen and snow melts in spring time. Recent, landslides occurring in costal areas have effected on choosing the Gerze area. In order to determine the landslides occurring in Gerze, field and laboratory studies have been carried out. 30 sample location was choose as 5 sample per each km2. After determining landslide areas, distributed and undistributed samples were taken for laboratory experiments and clay content. Based on field studies and laboratory experiment, five landslides were determined, called Deniz Feneri, Zenginler Sitesi, Bedre, Mezbahane and Ucuk. These landslides are still active, and their slopes are unstable. So, tension crakes are still seen behind of landslide main mirrors. Of them, The Uçuk landslide has two different secondary slope surfaces and is also reactive landslide. Springs are observed in both slope surface of the Uçuk landslide. The Mezbahane landslide has circular slope plane and tongue shape. The Deniz Feneri and Zenginler Sitesi landslides show different types of, activity and water content so they maybe classified as complex structure. The Deniz Feneri landslide has some tension crack, between 60 cm and 80 cm in depth. The Bedre landslide has half moon shape. GPS measurements in The Deniz Feneri and The Uçuk landslides were calculated to find out safety factors stable5 program according to Janbu and Bishop methods. The safety factors of the Deniz Feneri and The Uçuk landslides are between 0.489 -0.418 and 0.635-0.608, respectively. Since these landslides were affected negatively by Samsun-Sinop highway, load and brook, these negative effects were eliminated and safety factors recalculated. The recalculated safety factors between 0.855-0.889 and 0.976-0.905, respectively. It was determined that water content and loads have effected negatively to these landslides. The study area consists of sedimentary rocks. Most of landslides in study area occurred in weathered soil. Geotechnical properties of the soil samples collected; the specific unit weight 2.60 and 2.80 gr/cm3, water content 15% and 33%, natural unit weight 2.610 and 2.09 gr/cm3, dry unit weight, 1.28 and 1.86 gr/cm3, porosity 29% and 61%. The soil samples contain 27.49% clay, 29.92% silt, 11.08% sand, and 11.33% gravel based on grain size distribution. Soil samples have liquid limit values between 36% and 75% and plasticity index values, between 13% and 45%. The Soil samples for the study area show high and very high plasticity, called solid and very solid. According to USCS most of the soil samples were determined unctuous clay. Clays can be classified normal and non-active and their swelling potential medium-high. Cohesion of soils the samples are between 0.027 and 0.579 kg/cm2, internal friction angels are between 29.5 and 7.53, free compressive strength are between 1.89 and 5.5 kg/ cm2.

  20. Electrical properties of toad sartorius muscle fibres in summer and winter.

    PubMed

    Dulhunty, A F; Gage, P W

    1973-05-01

    1. The area and circumference of surface fibres of sartorius muscles were measured from photomicrographs of frozen sections of whole muscles, and compared with the values obtained assuming a circular cross-section. The latter assumption gave an over-estimate of the mean area of 28%, but only a 2% over-estimate of the circumference. In isolated, single fibres, the assumption gave over-estimates of 25 and 6%, of area and circumference respectively.2. The passive electrical properties of fibres were different in summer and winter. The mean internal resistivity, membrane resistance and membrane capacitance were 147 Omega.cm, 7.6 kOmega.cm(2) and 4 muF/cm(2) in summer, and 194 Omega.cm, 3.9 kOmega.cm(2) and 6.7 muF/cm(2) in winter, in fibres of comparable diameters in situ. In single fibres in summer, the mean values were 120 Omega.cm, 8.6 kOmega.cm(2) and 3.6 muF/cm(2).3. In glycerol-treated fibres the mean specific membrane capacitance was 1.0 muF/cm(2) in summer and 2.0 muF/cm(2) in winter. The internal resistivity and specific membrane resistance were 167 Omega.cm and 8.9 kOmega.cm(2) in summer, and 232 Omega.cm and 3.9 kOmega.cm(2) in winter.4. Early after-depolarizations were recorded in glycerol-treated fibres which had a low membrane capacitance, did not twitch and showed little ;creep'. Electron micrographs of glycerol-treated fibres showed disruption of the transverse tubular system and sarcoplasmic reticulum.5. After exposure of muscles to 400 mM urea or acetamide for 1 hr, muscle fibres did not twitch and had a reduced membrane capacitance in Ringer solution.

  1. Evaluation of the Effects of Sildenafil Citrate (Viagra) on Vertebral Artery Blood Flow in Patients with Vertebro-Basilar Insufficiency

    PubMed Central

    Berilgen, Sait; Ozdemir, Huseyin; Tekatas, Aslan; Ogur, Erkin

    2008-01-01

    Objective To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). Materials and Methods The study included 21 patients with VBI (aged 31-76; mean 61.0 ± 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Results Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm2 to 10.80 cm2 at 45 minutes and 10.81 cm2 at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Conclusion Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs. PMID:19039262

  2. Phosphorous doped p-type MoS2 polycrystalline thin films via direct sulfurization of Mo film

    NASA Astrophysics Data System (ADS)

    Momose, Tomohiro; Nakamura, Atsushi; Daniel, Moraru; Shimomura, Masaru

    2018-02-01

    We report on the successful synthesis of a p-type, substitutional doping at S-site, MoS2 thin film using Phosphorous (P) as the dopant. MoS2 thin films were directly sulfurized for molybdenum films by chemical vapor deposition technique. Undoped MoS2 film showed n-type behavior and P doped samples showed p-type behavior by Hall-effect measurements in a van der Pauw (vdP) configuration of 10×10 mm2 area samples and showed ohmic behavior between the silver paste contacts. The donor and the acceptor concentration were detected to be ˜2.6×1015 cm-3 and ˜1.0×1019 cm-3, respectively. Hall-effect mobility was 61.7 cm2V-1s-1 for undoped and varied in the range of 15.5 ˜ 0.5 cm2V-1s-1 with P supply rate. However, the performance of field-effect transistors (FETs) declined by double Schottky barrier contacts where the region between Ni electrodes on the source/drain contact and the MoS2 back-gate cannot be depleted and behaves as a 3D material when used in transistor geometry, resulting in poor on/off ratio. Nevertheless, the FETs exhibit hole transport and the field-effect mobility showed values as high as the Hall-effect mobility, 76 cm2V-1s-1 in undoped MoS2 with p-type behavior and 43 cm2V-1s-1 for MoS2:P. Our findings provide important insights into the doping constraints for transition metal dichalcogenides.

  3. Commissioning of a PTW 34070 large-area plane-parallel ionization chamber for small field megavoltage photon dosimetry.

    PubMed

    Kupfer, Tom; Lehmann, Joerg; Butler, Duncan J; Ramanathan, Ganesan; Bailey, Tracy E; Franich, Rick D

    2017-11-01

    This study investigates a large-area plane-parallel ionization chamber (LAC) for measurements of dose-area product in water (DAP w ) in megavoltage (MV) photon fields. Uniformity of electrode separation of the LAC (PTW34070 Bragg Peak Chamber, sensitive volume diameter: 8.16 cm) was measured using high-resolution microCT. Signal dependence on angle α of beam incidence for square 6 MV fields of side length s = 20 cm and 1 cm was measured in air. Polarity and recombination effects were characterized in 6, 10, and 18 MV photons fields. To assess the lateral setup tolerance, scanned LAC profiles of a 1 × 1 cm 2 field were acquired. A 6 MV calibration coefficient, N D ,w, LAC , was determined in a field collimated by a 5 cm diameter stereotactic cone with known DAP w . Additional calibrations in 10 × 10 cm 2 fields at 6, 10, and 18 MV were performed. Electrode separation is uniform and agrees with specifications. Volume-averaging leads to a signal increase proportional to ~1/cos(α) in small fields. Correction factors for polarity and recombination range between 0.9986 to 0.9996 and 1.0007 to 1.0024, respectively. Off-axis displacement by up to 0.5 cm did not change the measured signal in a 1 × 1 cm 2 field. N D ,w, LAC was 163.7 mGy cm -2 nC -1 and differs by +3.0% from the coefficient derived in the 10 × 10 cm 2 6 MV field. Response in 10 and 18 MV fields increased by 1.0% and 2.7% compared to 6 MV. The LAC requires only small correction factors for DAP w measurements and shows little energy dependence. Lateral setup errors of 0.5 cm are tolerated in 1 × 1 cm 2 fields, but beam incidence must be kept as close to normal as possible. Calibration in 10 × 10 fields is not recommended because of the LAC's over-response. The accuracy of relative point-dose measurements in the field's periphery is an important limiting factor for the accuracy of DAP w measurements. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  4. Ultrasonic prediction of carcass merit in beef cattle: evaluation of technician effects on ultrasonic estimates of carcass fat thickness and longissimus muscle area.

    PubMed

    Perkins, T L; Green, R D; Hamlin, K E; Shepard, H H; Miller, M F

    1992-09-01

    The objective of this study was to determine technician effects of live animal ultrasonic estimates of fat thickness (FTU) and longissimus muscle area (LMAU). Steers (n = 36) representing four breed-types (Brown Swiss, Average Zebu-cross Mexican, Corriente Mexican, and typical British crossbred) of commercial slaughter cattle were isonified to estimate accuracy and repeatability of fat thickness (FT) and longissimus muscle area (LMA) measurements by two experienced technicians. Repeated measures of FTU and LMAU were taken by technicians on two consecutive days with an Aloka 500V ultrasound unit equipped with a 3.5-MHz, 172-mm scanning width, linear-array transducer. Ultrasonic estimates of fat thickness and LMAU were taken at the 12th and 13th rib interface 48 h before slaughter; carcass fat thickness (FTC) and longissimus muscle area (LMAC) were measured 48 h postmortem. Means for FTU, FTC, LMAU, and LMAC were .91 +/- .36 cm, .82 +/- .40 cm, 70.7 +/- 9.43 cm2, and 72.4 +/- 8.9 cm2, respectively. Ultrasound and carcass measures of FT and LMA were different (P less than .01) among breed-types but were not different (P greater than .10) between technicians or for technician x breed-type interactions. Pooled simple correlation coefficients (P less than .01) were .87 and .86 between FTU and FTC and .76 and .82 between LMAU and LMAC for Technicians 1 and 2, respectively. Repeatabilities estimated by intraclass correlation methods were .91 +/- .03 and .81 +/- .06 for images repeated over 2 d and .95 +/- .02 and .83 +/- .05 for images repeated by two technicians for FT and LMA, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. The effect of weight change on changes in breast density measures over menopause in a breast cancer screening cohort.

    PubMed

    Wanders, Johanna Olga Pauline; Bakker, Marije Fokje; Veldhuis, Wouter Bernard; Peeters, Petra Huberdina Maria; van Gils, Carla Henrica

    2015-05-30

    High weight and high percentage mammographic breast density are both breast cancer risk factors but are negatively correlated. Therefore, we wanted to obtain more insight into this apparent paradox. We investigated in a longitudinal study how weight change over menopause is related to changes in mammographic breast features. Five hundred ninety-one participants of the EPIC-NL cohort were divided into three groups according to their prospectively measured weight change over menopause: (1) weight loss (more than -3.0 %), (2) stable weight (between -3.0 % and +3.0 %), and (3) weight gain (more than 3.0 %). SPSS GLM univariate analysis was used to determine both the mean breast measure changes in, and the trend over, the weight change groups. Over a median period of 5 years, the mean changes in percent density in these groups were -5.0 % (95 % confidence interval (CI) -8.0; -2.1), -6.8 % (95 % CI -9.0; -4.5), and -10.2 % (95 % CI -12.5; -7.9), respectively (P-trend = 0.001). The mean changes in dense area were -16.7 cm(2) (95 % CI -20.1; -13.4), -16.4 cm(2) (95 % CI -18.9; -13.9), and -18.1 cm(2) (95 % CI -20.6; -15.5), respectively (P-trend = 0.437). Finally, the mean changes in nondense area were -6.1 cm(2) (95 % CI -11.9; -0.4), -0.6 cm(2) (95 % CI -4.9; 3.8), and 5.3 cm(2) (95 % CI 0.9; 9.8), respectively (P-trend < 0.001). Going through menopause is associated with a decrease in both percent density and dense area. Owing to an increase in the nondense tissue, the decrease in percent density is largest in women who gain weight. The decrease in dense area is not related to weight change. So the fact that both high percent density and high weight or weight gain are associated with high postmenopausal breast cancer risk can probably not be explained by an increase (or slower decrease) of dense area in women gaining weight compared with women losing weight or maintaining a stable weight. These results suggest that weight and dense area are presumably two independent postmenopausal breast cancer risk factors.

  6. A ventilation strategy during general anaesthesia to reduce postoperative atelectasis.

    PubMed

    Edmark, Lennart; Auner, Udo; Hallén, Jan; Lassinantti-Olowsson, Lena; Hedenstierna, Göran; Enlund, Mats

    2014-08-01

    Atelectasis is common during and after general anaesthesia. We hypothesized that a ventilation strategy, without recruitment manoeuvres, using a combination of continuous positive airway pressure (CPAP) or positive end-expiratory pressure (PEEP) and a reduced end-expiratory oxygen fraction (FETO2) before ending mask ventilation with CPAP after extubation would reduce the area of postoperative atelectasis. Thirty patients were randomized into three groups. During induction and emergence, inspiratory oxygen fractions (FIO2) were 1.0 in the control group and 1.0 or 0.8 in the intervention groups. No CPAP/PEEP was used in the control group, whereas CPAP/PEEP of 6 cmH2O was used in the intervention groups. After extubation, FIO2 was set to 0.30 in the intervention groups and CPAP was applied, aiming at FETO2 < 0.30. Atelectasis was studied by computed tomography 25 min postoperatively. The median area of atelectasis was 5.2 cm(2) (range 1.6-12.2 cm(2)) and 8.5 cm(2) (3-23.1 cm(2)) in the groups given FIO2 1.0 with or without CPAP/PEEP, respectively. After correction for body mass index the difference between medians (2.9 cm(2)) was statistically significant (confidence interval 0.2-7.6 cm(2), p = 0.04). In the group given FIO2 0.8, in which seven patients were ex- or current smokers, the median area of atelectasis was 8.2 cm(2) (1.8-14.7 cm(2)). Compared with conventional ventilation, after correction for obesity, this ventilation strategy reduced the area of postoperative atelectasis in one of the intervention groups but not in the other group, which included a higher proportion of smokers.

  7. A ventilation strategy during general anaesthesia to reduce postoperative atelectasis

    PubMed Central

    Auner, Udo; Hallén, Jan; Lassinantti-Olowsson, Lena; Hedenstierna, Göran; Enlund, Mats

    2014-01-01

    Background Atelectasis is common during and after general anaesthesia. We hypothesized that a ventilation strategy, without recruitment manoeuvres, using a combination of continuous positive airway pressure (CPAP) or positive end-expiratory pressure (PEEP) and a reduced end-expiratory oxygen fraction (FETO2) before ending mask ventilation with CPAP after extubation would reduce the area of postoperative atelectasis. Methods Thirty patients were randomized into three groups. During induction and emergence, inspiratory oxygen fractions (FIO2) were 1.0 in the control group and 1.0 or 0.8 in the intervention groups. No CPAP/PEEP was used in the control group, whereas CPAP/PEEP of 6 cmH2O was used in the intervention groups. After extubation, FIO2 was set to 0.30 in the intervention groups and CPAP was applied, aiming at FETO2 < 0.30. Atelectasis was studied by computed tomography 25 min postoperatively. Results The median area of atelectasis was 5.2 cm2 (range 1.6–12.2 cm2) and 8.5 cm2 (3–23.1 cm2) in the groups given FIO2 1.0 with or without CPAP/PEEP, respectively. After correction for body mass index the difference between medians (2.9 cm2) was statistically significant (confidence interval 0.2–7.6 cm2, p = 0.04). In the group given FIO2 0.8, in which seven patients were ex- or current smokers, the median area of atelectasis was 8.2 cm2 (1.8–14.7 cm2). Conclusion Compared with conventional ventilation, after correction for obesity, this ventilation strategy reduced the area of postoperative atelectasis in one of the intervention groups but not in the other group, which included a higher proportion of smokers. PMID:24758245

  8. Comparison of water wash, trimming, and combined hot water and lactic acid treatments for reducing bacteria of fecal origin on beef carcasses.

    PubMed

    Castillo, A; Lucia, L M; Goodson, K J; Savell, J W; Acuff, G R

    1998-07-01

    Cleaning treatments, such as high-pressure water wash at 35 degrees C or trim, alone and combined with sanitizing treatments, such as hot water (95 degrees C at the source), warm (55 degrees C) 2% lactic acid spray, and combinations of these two sanitizing methods, were compared for their effectiveness in reducing inoculated numbers (5.0 to 6.0 log CFU/cm2) of Salmonella typhimurium, Escherichia coli O157:H7, aerobic plate counts, Enterobacteriaceae, total coliforms, thermotolerant coliforms, and generic E. coli on hot beef carcass surface areas in a model carcass spray cabinet. Log reductions in numbers of all tested organisms by water wash or trim alone were significantly smaller than the log reductions obtained by the different combined treatments. Regardless of the cleaning treatment (water wash or trim) or surface area, the range for mean log reductions by hot water was from 4.0 to > 4.8 log CFU/cm2, by lactic acid spray was from 4.6 to > 4.9 log CFU/cm2, by hot water followed by lactic acid spray was from 4.5 to > 4.9 log CFU/cm2, and by lactic acid spray followed by hot water was from 4.4 to > 4.6 log CFU/cm2, for S. typhimurium and E. coli O157:H7. Identical reductions were obtained for thermotolerant coliforms and generic E. coli. No differences in bacterial reductions were observed for different carcass surface regions. Water wash and trim treatments caused spreading of the contamination to other areas of the carcass surface while providing an overall reduction in fecal or pathogenic contamination on carcass surface areas. This relocated contamination after either water wash or trim was most effectively reduced by following with hot water and then lactic acid spray. This combined treatment yielded 0% positive samples for S. typhimurium, E. coli O157:H7, thermotolerant coliforms, and generic E. coli on areas outside the inoculated areas, whereas percent positive samples after applying other combined treatments ranged from 22 to 44% for S. typhimurium, 0 to 44% for E. coli O157:H7, and 11 to 33% for both thermotolerant coliforms and generic E. coli. From data collected in this study, it is possible to choose an effective, inexpensive treatment to reduce bacterial contamination on beef carcasses. In addition, the similar reduction rates of total coliforms, thermotolerant coliforms, or generic E. coli may be useful in identifying an indicator to verify the effectiveness of the selected treatment as a critical control point in a Hazard Analysis and Critical Control Point program.

  9. Cardiac valve orifice equation independent of valvular flow intervals: application to mitral valve area computation in mitral stenosis and comparison with the Gorlin formula and direct anatomical measurements.

    PubMed

    Seitz, W; Marino, P; Zanolla, L; Buonanno, C; McIlroy, M; Spiel, M

    1984-11-01

    An orifice equation is developed which relates the effective mitral valve area (A), the average mitral valve pressure gradient (dP), the cardiac output (Q) and the heart frequency (f) through considerations of momentum conservation across the mitral valve. The form of the new equation is A = (4.75 X 10(-5)Qf/dP, where A, Q, and dP are expressed in cm2, ml X min-1 and mmHg respectively. Mitral valve areas computed with the new orifice formula are found to correlate with those computed by the Gorlin formula in conditions of equilibrium associated with the resting state at a level of r = 0.95, SE = 0.15 cm2, with autopsy measurements at a level of r = 0.85, SE = 0.18 cm2 and with direct anatomical measurements of excised valves at a level of r = 0.78, SE = 0.41 cm2. The results suggest that the new formula may be considered as an independent orifice equation enjoying a similar domain of validity as the Gorlin formula. The new equation offers the possibility of deriving additional useful haemodynamic relationships when used in combination with established cardiological formulas.

  10. Investigation of the radiation resistance of triple-junction a-Si:H alloy solar cells irradiated with 1.00 MeV protons

    NASA Technical Reports Server (NTRS)

    Lord, Kenneth R., II; Walters, Michael R.; Woodyard, James R.

    1993-01-01

    The effect of 1.00 MeV proton irradiation on hydrogenated amorphous silicon alloy triple-junction solar cells is reported for the first time. The cells were designed for radiation resistance studies and included 0.35 cm(sup 2) active areas on 1.0 by 2.0 cm(sup 2) glass superstrates. Three cells were irradiated through the bottom contact at each of six fluences between 5.10E12 and 1.46E15 cm(sup -2). The effect of the irradiations was determined with light current-voltage measurements. Proton irradiation degraded the cell power densities from 8.0 to 98 percent for the fluences investigated. Annealing irradiated cells at 200 C for two hours restored the power densities to better than 90 percent. The cells exhibited radiation resistances which are superior to cells reported in the literature for fluences less than 1E14 cm(sup -2).

  11. Design of a transportable high efficiency fast neutron spectrometer

    DOE PAGES

    Roecker, C.; Bernstein, A.; Bowden, N. S.; ...

    2016-04-12

    A transportable fast neutron detection system has been designed and constructed for measuring neutron energy spectra and flux ranging from tens to hundreds of MeV. The transportability of the spectrometer reduces the detector-related systematic bias between different neutron spectra and flux measurements, which allows for the comparison of measurements above or below ground. The spectrometer will measure neutron fluxes that are of prohibitively low intensity compared to the site-specific background rates targeted by other transportable fast neutron detection systems. To measure low intensity high-energy neutron fluxes, a conventional capture-gating technique is used for measuring neutron energies above 20 MeV andmore » a novel multiplicity technique is used for measuring neutron energies above 100 MeV. The spectrometer is composed of two Gd containing plastic scintillator detectors arranged around a lead spallation target. To calibrate and characterize the position dependent response of the spectrometer, a Monte Carlo model was developed and used in conjunction with experimental data from gamma ray sources. Multiplicity event identification algorithms were developed and used with a Cf-252 neutron multiplicity source to validate the Monte Carlo model Gd concentration and secondary neutron capture efficiency. The validated Monte Carlo model was used to predict an effective area for the multiplicity and capture gating analyses. For incident neutron energies between 100 MeV and 1000 MeV with an isotropic angular distribution, the multiplicity analysis predicted an effective area of 500 cm 2 rising to 5000 cm 2. For neutron energies above 20 MeV, the capture-gating analysis predicted an effective area between 1800 cm 2 and 2500 cm 2. As a result, the multiplicity mode was found to be sensitive to the incident neutron angular distribution.« less

  12. Effects of Mitral Annulus Remodeling Following MitraClip Procedure on Reduction of Functional Mitral Regurgitation.

    PubMed

    Hidalgo, Francisco; Mesa, Dolores; Ruiz, Martín; Delgado, Mónica; Rodríguez, Sara; Pardo, Laura; Pan, Manuel; López, Amador; Romero, Miguel A; Suárez de Lezo, José

    2016-11-01

    The percutaneous mitral valve repair procedure (MitraClip) appears to reduce mitral annulus diameter in patients with functional mitral regurgitation, but the relationship between this and regurgitation severity has not been demonstrated. The aim of this study was to determine the effect of mitral annulus remodeling on the reduction of mitral regurgitation in patients with functional etiology. The study included all patients with functional mitral regurgitation treated with MitraClip at our hospital until January 2015. Echocardiogram (iE33 model, Philips) was performed in all patients immediately after device positioning. Changes in the mitral annulus correlated with mitral regurgitation severity, as assessed using the effective regurgitant orifice area. The study included 23 patients (age, 65±14 years; 74% men; left ventricular ejection fraction, 31%±13%; systolic pulmonary artery pressure, 47±10 mmHg). After the procedure, the regurgitant orifice area decreased by 0.30 cm 2 ±0.04 cm 2 (P<.0005), from a baseline of 0.49 cm 2 ±0.09 cm 2 . Anteroposterior diameter decreased by 3.14 mm±1.01 mm (P<.0005) from a baseline of 28.27 mm±4.9 mm, with no changes in the intercommissural diameter (0.50 mm±0.91 mm vs 40.68 mm±4.7 mm; P=.26). A significant association was seen between anteroposterior diameter reduction and regurgitant orifice area reduction (r=.49; P=.020). In patients with functional mitral regurgitation, the MitraClip device produces an immediate reduction in the anteroposterior diameter. This remodeling may be related to the reduction in mitral regurgitation. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roecker, C.; Bernstein, A.; Bowden, N. S.

    A transportable fast neutron detection system has been designed and constructed for measuring neutron energy spectra and flux ranging from tens to hundreds of MeV. The transportability of the spectrometer reduces the detector-related systematic bias between different neutron spectra and flux measurements, which allows for the comparison of measurements above or below ground. The spectrometer will measure neutron fluxes that are of prohibitively low intensity compared to the site-specific background rates targeted by other transportable fast neutron detection systems. To measure low intensity high-energy neutron fluxes, a conventional capture-gating technique is used for measuring neutron energies above 20 MeV andmore » a novel multiplicity technique is used for measuring neutron energies above 100 MeV. The spectrometer is composed of two Gd containing plastic scintillator detectors arranged around a lead spallation target. To calibrate and characterize the position dependent response of the spectrometer, a Monte Carlo model was developed and used in conjunction with experimental data from gamma ray sources. Multiplicity event identification algorithms were developed and used with a Cf-252 neutron multiplicity source to validate the Monte Carlo model Gd concentration and secondary neutron capture efficiency. The validated Monte Carlo model was used to predict an effective area for the multiplicity and capture gating analyses. For incident neutron energies between 100 MeV and 1000 MeV with an isotropic angular distribution, the multiplicity analysis predicted an effective area of 500 cm 2 rising to 5000 cm 2. For neutron energies above 20 MeV, the capture-gating analysis predicted an effective area between 1800 cm 2 and 2500 cm 2. As a result, the multiplicity mode was found to be sensitive to the incident neutron angular distribution.« less

  14. Effects of low level laser in the morphology of the skeletal muscle fiber during compensatory hypertrophy in plantar muscle of rats

    NASA Astrophysics Data System (ADS)

    Terena, Stella Maris Lins; Fernandes, Kristianne Porta Santos; Kalil, Sandra; Alves, Agnelo Neves; Mesquita Ferrari, Raquel Agnelli

    2015-06-01

    The hypertrophy is known as an increase the cross-sectional area of the muscle as a result of a muscular work against an overload, and it is compensatory because the overload is induced by functional elimination of synergistic muscles. The importance of study the compensatory hypertrophy is understand how this process can be influenced by the irradiation with regard to the weight and muscle cross-sectional area, to assist in the rehabilitation process and the effectiveness functional return. The aim was evaluate the effects of low-level laser irradiation on morphological aspects of muscle tissue, comparing the weight and cross-sectional area in rat skeletal muscle. Wistar rats were divided into three groups: control, hypertrophy group without irradiation (right plantar muscle) and hypertrophy group and irradiation (left plantar muscle), both analyzed after 7 and 14 days. The irradiation was performed daily immediately after the surgery. The parameters were: λ = 780nm, beam spot of 0.04 cm2, output power of 40mW, power density of 1W/cm2, energy density of 10J / cm2 and 10s exposure time with a total energy of 3.2 J. The results revealed that low level laser irradiation an increase the weight of the plantaris muscle after 7 and 14 days with a difference of 7.06% and 11.51% respectively. In conclusion, low level laser irradiation has an effect on compensatory hypertrophy to produce increased muscle weight and promoted an increase in cross-sectional area of muscle fibers in the compensatory hypertrophy model after 14 days with parameters cited above.

  15. Treatment of burning mouth syndrome with a low-level energy diode laser.

    PubMed

    Yang, Hui-Wen; Huang, Yu-Feng

    2011-02-01

    To test the therapeutic efficacy of low-level energy diode laser on burning mouth syndrome. Burning mouth syndrome is characterized by burning and painful sensations in the mouth, especially the tongue, in the absence of significant mucosal abnormalities. Although burning mouth syndrome is relatively common, little is known regarding its etiology and pathophysiology. As a result, no treatment is effective in all patients. Low-level energy diode laser therapy has been used in a variety of chronic and acute pain conditions, including neck, back and myofascial pain, degenerative osteoarthritis, and headache. A total of 17 patients who had been diagnosed with burning mouth syndrome were treated with an 800-nm wavelength diode laser. A straight handpiece was used with an end of 1-cm diameter with the fiber end standing 4 cm away from the end of handpiece. When the laser was applied, the handpiece directly contacted or was immediately above the symptomatic lingual surface. The output used was 3 W, 50 msec intermittent pulsing, and a frequency of 10 Hz, which was equivalent to an average power of 1.5 W/cm(2) (3 W × 0.05 msec × 10 Hz = 1.5 W/cm(2)). Depending on the involved area, laser was applied to a 1-cm(2) area for 70 sec until all involved area was covered. Overall pain and discomfort were analyzed with a 10-cm visual analogue scale. All patients received diode laser therapy between one and seven times. The average pain score before the treatment was 6.7 (ranging from 2.9 to 9.8). The results showed an average reduction in pain of 47.6% (ranging from 9.3% to 91.8%). The burning sensation remained unchanged for up to 12 months. Low-level energy diode laser may be an effective treatment for burning mouth syndrome.

  16. Surface States and Effective Surface Area on Photoluminescent P-Type Porous Silicon

    NASA Technical Reports Server (NTRS)

    Weisz, S. Z.; Porras, A. Ramirez; Resto, O.; Goldstein, Y.; Many, A.; Savir, E.

    1997-01-01

    The present study is motivated by the possibility of utilizing porous silicon for spectral sensors. Pulse measurements on the porous-Si/electrolyte system are employed to determine the surface effective area and the surface-state density at various stages of the anodization process used to produce the porous material. Such measurements were combined with studies of the photoluminescence spectra. These spectra were found to shift progressively to the blue as a function of anodization time. The luminescence intensity increases initially with anodization time, reaches a maximum and then decreases with further anodization. The surface state density, on the other hand, increases with anodization time from an initial value of about 2 x 10(exp 12)/sq cm surface to about 1013 sq cm for the anodized surface. This value is attained already after -2 min anodization and upon further anodization remains fairly constant. In parallel, the effective surface area increases by a factor of 10-30. This behavior is markedly different from the one observed previously for n-type porous Si.

  17. [Simultaneous determination of multiple elements in airborne particulate samples by X-ray fluorescence spectrometry].

    PubMed

    Takada, T; Hitosugi, M; Kadowaki, T; Kudo, M

    1983-07-01

    An energy dispersive X-ray fluorescence spectrometer (EDX) has been applied to determine multielements in the workplace air. The standards for X-ray fluorescence analysis were prepared by the chelate precipitation method on polyvinyl chloride (PVC) membrane filter. And, the specimens were prepared to deposit various metal compounds of different chemical forms by the suspension method on PVC membrane filter, and they were determined with EDX and atomic absorption spectrometer (AAS). The results obtained were as follows. Though there is a difference by each element, an amount less than 3 microgram/cm2 per unit area makes it possible to undergo multielement analysis, that is, is has no influence on fine particle effect (particle size; under 5 microns). Then, effects of the X-ray intensity by different chemical forms are negligible. At the presence the neighboring element and other elements this technique showed greater precision by carrying out on corrective treatment, etc. The coefficient of variation of this technique was in the range of 2.5-6.5% at DDTC-Cu of 0.5-5.0 micrograms/cm2, with the limit of detection for As : 0.002 microgram/cm2, Zn : 0.003 microgram/cm2, Pb : 0.003 microgram/cm2, Cu : 0.004 microgram/cm2, Ni : 0.003 microgram/cm2, Fe : 0.005 microgram/cm2, Mn : 0.008 microgram/cm2, Cr : 0.013 microgram/cm2, respectively. Aerosols collected at the workplace were analyzed with EDX and AAS, and the obtained results showed good agreement with such regression line as y = 1.04 chi + 0.04, the coefficient of correlation being r = 0.995. From these results, this technique was found to be a very excellent method for monitoring of multielements in the workplace air.

  18. Outstanding supercapacitive properties of Mn-doped TiO2 micro/nanostructure porous film prepared by anodization method

    PubMed Central

    Ning, Xuewen; Wang, Xixin; Yu, Xiaofei; Zhao, Jianling; Wang, Mingli; Li, Haoran; Yang, Yang

    2016-01-01

    Mn-doped TiO2 micro/nanostructure porous film was prepared by anodizing a Ti-Mn alloy. The film annealed at 300 °C yields the highest areal capacitance of 1451.3 mF/cm2 at a current density of 3 mA/cm2 when used as a high-performance supercapacitor electrode. Areal capacitance retention is 63.7% when the current density increases from 3 to 20 mA/cm2, and the capacitance retention is 88.1% after 5,000 cycles. The superior areal capacitance of the porous film is derived from the brush-like metal substrate, which could greatly increase the contact area, improve the charge transport ability at the oxide layer/metal substrate interface, and thereby significantly enhance the electrochemical activities toward high performance energy storage. Additionally, the effects of manganese content and specific surface area of the porous film on the supercapacitive performance were also investigated in this work. PMID:26940546

  19. Clinical efficacies of shampoos containing ciclopirox olamine (1.5%) and ketoconazole (2.0%) in the treatment of seborrhoeic dermatitis.

    PubMed

    Ratnavel, Ravi C; Squire, Ruth A; Boorman, Graham C

    2007-01-01

    Ciclopirox olamine (CPO) is a broad-spectrum antifungal with anti-inflammatory properties effective against the yeast implicated in seborrhoeic dermatitis, Malassezia spp. This study compared 1.5% CPO shampoo with 2.0% ketoconazole shampoo and placebo in scalp seborrhoeic dermatitis. A randomized, double-blind, 4-week treatment period was preceded by a 2-week run-in period and followed by a 2-week run-out period. A total of 350 patients (150 CPO, 150 ketoconazole, 50 placebo) were enrolled. Assessments included scalp area affected, the severity of scaling, erythema, itching and scaling, and overall signs and symptoms. Both shampoos were significantly more effective than placebo in reducing the area affected. The mean reduction from baseline to end of treatment was 48.2 cm(2) with CPO, 41.4 cm(2) with ketoconazole and 20.0 cm(2) with placebo. Patients rated the CPO shampoo as superior to placebo (p<0.001) and ketoconazole shampoo (p<0.05) on the basis of overall signs and symptoms. Assessments of itching and scaling were also significantly in favour of the CPO shampoo over placebo at the end of treatment. All three shampoos were well tolerated. CPO shampoo was superior to placebo and at least as effective as ketoconazole shampoo in treating scalp seborrhoeic dermatitis. Patients rated the overall improvement as better with CPO than with ketoconazole shampoo.

  20. Seasonal variability of hydro-physical conditions in Faxinal system subtropical climate in southern Brazil.

    NASA Astrophysics Data System (ADS)

    Antoneli, Valdemir; Thomaz, Edivaldo; Berdnaz, João

    2015-04-01

    The Faxinal System is a form of peasant organization, existing in the Center-South region of Paraná State which is subject to extensive livestock breeding in a common breeding site; forest harvesting within the common breeding site and subsistence feeding polyculture out of faxinal limits. The organization of Faxinal occurs through the fencing of the entire area of faxinal, without boundaries between the properties where the common breeding works. All owners have the right to raise their animals (bovine, equine, etc.) roaming free. The breeding site consists of outdoor areas (natural pastures) and secondary forest areas. The form of creation without properties restriction (roaming free) is identified as the main factor of soil erosion and land degradation due to constant grazing. The trampling ends up compacting and influencing the physical conditions of the soil which lead to the reduction of leakage and increasing the erosive processes. Based on the above considerations, the objective of this study was to evaluate the compression and water infiltration to the soil in a Faxinal in the South Central Region of Paraná - Brazil. The presented data was collected in a pasture site and secondary forest, both with constant grazing (breeding area) and an area with uncounted animals (control area) out of Faxinal limits. Two collection campaigns were carried out as follows: August (winter) and January (summer). In each collection campaign ten (10) infiltration repetitions were made in each area. In each infiltration test 15 compression collections were performed in each infiltration area, totaling 150 repetitions in each campaign. For the evaluation of water infiltration into the soil, a manual concentric cylindrics infiltrometer was used with readings each 5 minutes during one hour. The Compression was collected with the aid of a pocket penetrometer with a value of 4.5 kgf / cm2. The Infiltration in August was of 26.7 cm / h in secondary forest, 19.1 cm / h in grassland, and 46.1 cm / h in Native Forest. The infiltration in the secondary forest in January was of 32.3 cm / h (29.9% higher than in August). The pasture indicated infiltration of 12.8 cm / h (32.9% lower) and 49.2 cm / h native forest (6.3% higher). Soil compaction in August was of 2.9 kgf / cm2 in the secondary forest, 3.7 kgf / cm2 in the pasture, and 1.4 kgf / cm2 in the Native Forest. In January, compression was of 2.1 in Secondary Forest (27.6% less than in August), 4.0 kgf / cm2 in the pasture (7.5% higher) and 1.3 kgf / cm2 in the native Forest (7.1% lower). These variations may be associated to the climatic conditions which cause some frost in winter promoting greater mobilization of animals looking for food in secondary forest areas due to reduced pasture. The springs from the pasture in summer enhances the time animals stay in the pasture areas. The influence of animals on hydrogeomorphic conditions in faxinal areas was evident, especially when comparing the data from the two areas with the ones indicated by the Native Forest.

  1. In situ quantitative analysis of individual H2O-CO2 fluid inclusions by laser Raman spectroscopy

    USGS Publications Warehouse

    Azbej, T.; Severs, M.J.; Rusk, B.G.; Bodnar, R.J.

    2007-01-01

    Raman spectral parameters for the Raman ??1 (1285??cm- 1) and 2??2 (1388??cm- 1) bands for CO2 and for the O-H stretching vibration band of H2O (3600??cm- 1) were determined in H2O-CO2 fluid inclusions. Synthetic fluid inclusions containing 2.5 to 50??mol% CO2 were analyzed at temperatures equal to or greater than the homogenization temperature. The results were used to develop an empirical relationship between composition and Raman spectral parameters. The linear peak intensity ratio (IR = ICO2/(ICO2 + IH2O)) is related to the CO2 concentration in the inclusion according to the relation:Mole % C O2 = e- 3.959 IR2 + 8.0734 IRwhere ICO2 is the intensity of the 1388 cm- 1 peak and IH2O is the intensity of the 3600 cm- 1 peak. The relationship between linear peak intensity and composition was established at 350????C for compositions ranging from 2.5 to 50??mol% CO2. The CO2-H2O linear peak intensity ratio (IR) varies with temperature and the relationship between composition and IR is strictly valid only if the inclusions are analyzed at 350????C. The peak area ratio is defined as AR = ACO2/(ACO2 + AH2O), where ACO2 is the integrated area under the 1388??cm- 1 peak and AH2O is the integrated area under the 3600??cm- 1 peak. The relationship between peak area ratio (AR) and the CO2 concentration in the inclusions is given as:Mole % C O2 = 312.5 AR. The equation relating peak area ratio and composition is valid up to 25??mol% CO2 and from 300 to 450????C. The relationship between linear peak intensity ratio and composition should be used for inclusions containing ??? 50??mol% CO2 and which can be analyzed at 350????C. The relationship between composition and peak area ratios should be used when analyzing inclusions at temperatures less than or greater than 350????C (300-450) but can only be used for compositions ??? 25??mol% CO2. Note that this latter relationship has a somewhat larger standard deviation compared to the intensity ratio relationship. Calibration relationships employing peak areas for both members of the Fermi diad (??1 at 1285??cm- 1 and 2??2 at 1388??cm- 1) were slightly poorer than those using only the 2??2 (1388??cm- 1) member owing to interference from quartz peak at approximately 1160??cm- 1. The technique has been applied to natural low-salinity H2O-CO2 inclusions from the Butte, Montana, porphyry copper-molybdenum deposit. Carbon dioxide concentrations obtained range from below detection to 4.2??mol% CO2, and are in good agreement with concentrations determined previously based on microthermometric and petrographic observations. ?? 2007 Elsevier B.V. All rights reserved.

  2. Environmental assessment for the Satellite Power System (SPS): Studies of honey bees exposed to 2.45 GHz continuous wave electromagnetic energy

    NASA Technical Reports Server (NTRS)

    Gary, N. E.; Westerdahl, B. B.

    1980-01-01

    Post treatment brood development was normal and teratological effects were not detected at exposures of 3 to 50 mw sq cm for 30 minutes. Post treatment survival, longevity, orientation, navigation, and memory of adult bees were also normal after exposures of 3 to 50 mw sq cm for 30 minutes. Post treatment longevity of confined bees in the laboratory was normal after exposures of 3 to 50 mw sq cm for 24 hours. Thermoregulation of brood nest, foraging activity, brood rearing, and social interaction were not affected by chronic exposure to 1 mw sq cm during 28 days. In dynamic behavioral bioassays the frequency of entry and duration of activity of unrestrained, foraging adult bees was identical in microwave exposed areas versus control areas.

  3. 5 × 5 cm2 silicon photonic crystal slabs on glass and plastic foil exhibiting broadband absorption and high-intensity near-fields

    PubMed Central

    Becker, C.; Wyss, P.; Eisenhauer, D.; Probst, J.; Preidel, V.; Hammerschmidt, M.; Burger, S.

    2014-01-01

    Crystalline silicon photonic crystal slabs are widely used in various photonics applications. So far, the commercial success of such structures is still limited owing to the lack of cost-effective fabrication processes enabling large nanopatterned areas (≫ 1 cm2). We present a simple method for producing crystalline silicon nanohole arrays of up to 5 × 5 cm2 size with lattice pitches between 600 and 1000 nm on glass and flexible plastic substrates. Exclusively up-scalable, fast fabrication processes are applied such as nanoimprint-lithography and silicon evaporation. The broadband light trapping efficiency of the arrays is among the best values reported for large-area experimental crystalline silicon nanostructures. Further, measured photonic crystal resonance modes are in good accordance with light scattering simulations predicting strong near-field intensity enhancements greater than 500. Hence, the large-area silicon nanohole arrays might become a promising platform for ultrathin solar cells on lightweight substrates, high-sensitive optical biosensors, and nonlinear optics. PMID:25073935

  4. Microwave ablation versus radiofrequency ablation in the kidney: high-power triaxial antennas create larger ablation zones than similarly sized internally cooled electrodes.

    PubMed

    Laeseke, Paul F; Lee, Fred T; Sampson, Lisa A; van der Weide, Daniel W; Brace, Christopher L

    2009-09-01

    To determine whether microwave ablation with high-power triaxial antennas creates significantly larger ablation zones than radiofrequency (RF) ablation with similarly sized internally cooled electrodes. Twenty-eight 12-minute ablations were performed in an in vivo porcine kidney model. RF ablations were performed with a 200-W pulsed generator and either a single 17-gauge cooled electrode (n = 9) or three switched electrodes spaced 1.5 cm apart (n = 7). Microwave ablations were performed with one (n = 7), two (n = 3), or three (n = 2) 17-gauge triaxial antennas to deliver 90 W continuous power per antenna. Multiple antennas were powered simultaneously. Temperatures 1 cm from the applicator were measured during two RF and microwave ablations each. Animals were euthanized after ablation and ablation zone diameter, cross-sectional area, and circularity were measured. Comparisons between groups were performed with use of a mixed-effects model with P values less than .05 indicating statistical significance. No adverse events occurred during the procedures. Three-electrode RF (mean area, 14.7 cm(2)) and single-antenna microwave (mean area, 10.9 cm(2)) ablation zones were significantly larger than single-electrode RF zones (mean area, 5.6 cm(2); P = .001 and P = .0355, respectively). No significant differences were detected between single-antenna microwave and multiple-electrode RF. Ablation zone circularity was similar across groups (P > .05). Tissue temperatures were higher during microwave ablation (maximum temperature of 123 degrees C vs 100 degrees C for RF). Microwave ablation with high-power triaxial antennas created larger ablation zones in normal porcine kidneys than RF ablation with similarly sized applicators.

  5. Efficient Monolithic Perovskite/Silicon Tandem Solar Cell with Cell Area >1 cm(2).

    PubMed

    Werner, Jérémie; Weng, Ching-Hsun; Walter, Arnaud; Fesquet, Luc; Seif, Johannes Peter; De Wolf, Stefaan; Niesen, Bjoern; Ballif, Christophe

    2016-01-07

    Monolithic perovskite/crystalline silicon tandem solar cells hold great promise for further performance improvement of well-established silicon photovoltaics; however, monolithic tandem integration is challenging, evidenced by the modest performances and small-area devices reported so far. Here we present first a low-temperature process for semitransparent perovskite solar cells, yielding efficiencies of up to 14.5%. Then, we implement this process to fabricate monolithic perovskite/silicon heterojunction tandem solar cells yielding efficiencies of up to 21.2 and 19.2% for cell areas of 0.17 and 1.22 cm(2), respectively. Both efficiencies are well above those of the involved subcells. These single-junction perovskite and tandem solar cells are hysteresis-free and demonstrate steady performance under maximum power point tracking for several minutes. Finally, we present the effects of varying the intermediate recombination layer and hole transport layer thicknesses on tandem cell photocurrent generation, experimentally and by transfer matrix simulations.

  6. Preparation and Characterization of Impregnated Commercial Rice Husks Activated Carbon with Piperazine for Carbon Dioxide (CO2) Capture

    NASA Astrophysics Data System (ADS)

    Masoum Raman, S. N.; Ismail, N. A.; Jamari, S. S.

    2017-06-01

    Development of effective materials for carbon dioxide (CO2) capture technology is a fundamental importance to reduce CO2 emissions. This work establishes the addition of amine functional group on the surface of activated carbon to further improve the adsorption capacity of CO2. Rice husks activated carbon were modified using wet impregnation method by introducing piperazine onto the activated carbon surfaces at different concentrations and mixture ratios. These modified activated carbons were characterized by using X-Ray Diffraction (XRD), Brunauer, Emmett and Teller (BET), Fourier Transform Infrared Spectroscopy (FTIR) and Field Emission Scanning Electron Microscopy (FESEM). The results from XRD analysis show the presence of polyethylene butane at diffraction angles of 21.8° and 36.2° for modified activated carbon with increasing intensity corresponding to increase in piperazine concentration. BET results found the surface area and pore volume of non-impregnated activated carbon to be 126.69 m2/g and 0.081 cm3/g respectively, while the modified activated carbons with 4M of piperazine have lower surface area and pore volume which is 6.77 m2/g and 0.015 cm3/g respectively. At 10M concentration, the surface area and pore volume are the lowest which is 4.48 m2/g and 0.0065 cm3/g respectively. These results indicate the piperazine being filled inside the activated carbon pores thus, lowering the surface area and pore volume of the activated carbon. From the FTIR analysis, the presence of peaks at 3312 cm-1 and 1636 cm-1 proved the existence of reaction between carboxyl groups on the activated carbon surfaces with piperazine. The surface morphology of activated carbon can be clearly seen through FESEM analysis. The modified activated carbon contains fewer pores than non-modified activated carbon as the pores have been covered with piperazine.

  7. Accurate Measurements of the Skin Surface Area of the Healthy Auricle and Skin Deficiency in Microtia Patients

    PubMed Central

    van Doremalen, Rob F. M.; Melchels, Ferry P. W.; Kolodzynski, Michail N.; Pouran, Behdad; Malda, Jos; Kon, Moshe; Breugem, Corstiaan C.

    2016-01-01

    Background: The limited cranial skin covering auricular implants is an important yet underrated factor in auricular reconstruction for both reconstruction surgery and tissue engineering strategies. We report exact measurements on skin deficiency in microtia patients and propose an accessible preoperative method for these measurements. Methods: Plaster ear models (n = 11; male:female = 2:1) of lobular-type microtia patients admitted to the University Medical Center Utrecht in The Netherlands were scanned using a micro-computed tomographic scanner or a cone-beam computed tomographic scanner. The resulting images were converted into mesh models from which the surface area could be calculated. Results: The mean total skin area of an adult-size healthy ear was 47.3 cm2, with 49.0 cm2 in men and 44.3 cm2 in women. Microtia ears averaged 14.5 cm2, with 15.6 cm2 in men and 12.6 cm2 in women. The amount of skin deficiency was 25.4 cm2, with 26.7 cm2 in men and 23.1 cm2 in women. Conclusions: This study proposes a novel method to provide quantitative data on the skin surface area of the healthy adult auricle and the amount of skin deficiency in microtia patients. We demonstrate that the microtia ear has less than 50% of skin available compared with healthy ears. Limited skin availability in microtia patients can lead to healing problems after auricular reconstruction and poses a significant challenge in the development of tissue-engineered cartilage implants. The results of this study could be used to evaluate outcomes and investigate new techniques with regard to tissue-engineered auricular constructs. PMID:28293505

  8. Effects of high thermal and high fast fluences on the mechanical properties of type 6061 aluminum in the HFBR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weeks, J.R.; Czajkowski, C.J.; Tichler, P.R.

    The High Flux Beam Reactor (HFBR) at Brookhaven National Laboratory (BNL) is an epithermal, externally moderated (by D/sub 2/O) facility designed to produce neutron beams for research. Type 6061 T-6 aluminum was used for the beam tubes, pressure vessel, fuel cladding, and most other components in the high flux area. The HFBR has operated since 1965. The epithermal, external moderation of the HFBR means that materials irradiated in different areas of the facility receive widely different flux spectra. Thus, specimens from a control rod drive follower tube (CRDF) have received 1.5 /times/ 10/sup 22/ n/cm/sup 2/ (E > 0.1 MeV)more » and 3.2 /times/ 10/sup 23/ n/cm/sup 2/ thermal fluence, while those from a vertical thimble flow shroud received 1.9 /times/ 10/sup 23/ n/cm/sup 2/ (E > 0.1 MeV) and 1.0 /times/ 10/sup 23/ n/cm/sup 2/ thermal. These numbers correspond to fast to thermal fluence ratios ranging from 0.05 to 1.9. Irradiations are occurring at approximately 333/degree/K. The data indicate that the increase in tensile strength and decrease in ductility result primarily from the thermal fluence, i.e., the transmutation of aluminum to silicon. These effects appear to be saturating at fluences above approximately 1.8 /times/ 10/sup 23/ n/cm/sup 2/ thermal at values of 90,000 psi (6700 Kg/mm/sup 2/) and 9%, respectively. The specimens receiving the highest fluence ratios appear to have less increase in tensile strength and less decrease in ductility than specimens with a lower fast to thermal fluence ratio and the same thermal fluence, suggesting a possible beneficial effect of the high energy neutrons in preventing formation of silicon crystallites. 7 refs., 11 figs., 3 tabs.« less

  9. Effect of Positive End-Expiratory Pressure on Central Venous Pressure in Patients under Mechanical Ventilation.

    PubMed

    Shojaee, Majid; Sabzghabaei, Anita; Alimohammadi, Hossein; Derakhshanfar, Hojjat; Amini, Afshin; Esmailzadeh, Bahareh

    2017-01-01

    Finding the probable governing pattern of PEEP and CVP changes is an area of interest for in-charge physicians and researchers. Therefore, the present study was designed with the aim of evaluating the relationship between the mentioned pressures. In this quasi-experimental study, patients under mechanical ventilation were evaluated with the aim of assessing the effect of PEEP change on CVP. Non-trauma patients, over 18 years of age, who were under mechanical ventilation and had stable hemodynamics, with inserted CV line were entered. After gathering demographic data, patients underwent 0, 5, and 10 cmH 2 O PEEPs and the respective CVPs of the mentioned points were recorded. The relationship of CVP and PEEP in different cut points were measured using SPSS 21.0 statistical software. 60 patients with the mean age of 73.95 ± 11.58 years were evaluated (68.3% male). The most frequent cause of ICU admission was sepsis with 45.0%. 5 cmH 2 O increase in PEEP led to 2.47 ± 1.53 mean difference in CVP level. If the PEEP baseline is 0 at the time of 5 cmH 2 O increase, it leads to a higher raise in CVP compared to when the baseline is 5 cmH 2 O (2.47 ± 1.53 vs. 1.57 ± 1.07; p = 0.039). The relationship between CVP and 5 cmH 2 O (p = 0.279), and 10 cmH 2 O (p = 0.292) PEEP changes were not dependent on the baseline level of CVP. The findings of this study revealed the direct relationship between PEEP and CVP. Approximately, a 5 cmH 2 O increase in PEEP will be associated with about 2.5 cmH 2 O raise in CVP. When applying a 5 cmH 2 O PEEP increase, if the baseline PEEP is 0, it leads to a significantly higher raise in CVP compared to when it is 5 cmH 2 O (2.5 vs. 1.6). It seems that sex, history of cardiac failure, baseline CVP level, and hypertension do not have a significant effect in this regard.

  10. 3D MnO2-graphene composites with large areal capacitance for high-performance asymmetric supercapacitors.

    PubMed

    Zhai, Teng; Wang, Fuxin; Yu, Minghao; Xie, Shilei; Liang, Chaolun; Li, Cheng; Xiao, Fangming; Tang, Renheng; Wu, Qixiu; Lu, Xihong; Tong, Yexiang

    2013-08-07

    In this paper, we reported an effective and simple strategy to prepare large areal mass loading of MnO2 on porous graphene gel/Ni foam (denoted as MnO2/G-gel/NF) for supercapacitors (SCs). The MnO2/G-gel/NF (MnO2 mass: 13.6 mg cm(-2)) delivered a large areal capacitance of 3.18 F cm(-2) (234.2 F g(-1)) and good rate capability. The prominent electrochemical properties of MnO2/G-gel/NF are attributed to the enhanced conductivities and improved accessible area for ions in electrolytes. Moreover, an asymmetric supercapacitor (ASC) based on MnO2/G-gel/NF (MnO2 mass: 6.1 mg cm(-2)) as the positive electrode and G-gel/NF as the negative electrode achieved a remarkable energy density of 0.72 mW h cm(-3). Additionally, the fabricated ASC device also exhibited excellent cycling stability, with less than 1.5% decay after 10,000 cycles. The ability to effectively develop SC electrodes with high mass loading should open up new opportunities for SCs with high areal capacitance and high energy density.

  11. Serial Surgical Debridement of Common Pressure Injuries in the Nursing Home Setting: Outcomes and Findings.

    PubMed

    Anvar, Bardia; Okonkwo, Henry

    2017-07-01

    This study examined the efficacy of bedside surgical debridement in a nursing home population. A retrospective chart review was performed of sacrum, sacrococcyx, coccyx, ischium, and trochanter (SSCIT) region pressure injuries in the Skilled Wound Care practice (Los Angeles, CA). The patient population was refined from 2128 to 227 patients visited 8 or more times during nursing home stays found to have 1 or more SSCIT pressure injuries. Of the 227 patients, there were approximately 319 individual SSCIT wounds, with an average of 1.4 SSCIT wounds per patient. Bedside surgical debridement was performed using a sharp excisional technique on 190 of 319 (59.5%) SSCIT wounds. An analysis of the square surface area of the 190 debrided wound sites revealed a mean ulcer surface area of 20.76 cm2. Of those 190 wound sites, 138 (73%) had a reduction in square surface area, and 52 (27%) had no change or an increase in square surface area and were categorized as nonresponders. Of the wounds that did improve by a reduction in wound surface area, the average wound surface area reduction was 6.81 cm2 at 4 weeks (25%), 8.91 cm2 reduction at 8 weeks (33%), and 10.87 cm2 reduction at 12 weeks (40%). From the 190 wound sites, there were a total of 43 (23%) wounds that had a square surface area of 0 (reepithelialized), which has a healing rate of 23%. Traditional bedside debridement provides excellent results in reducing the square surface area for a majority of wounds. Whether used alone or as an adjunct to any treatment plan, the use of surgical sharp equipment aids in achieving good wound healing and advancing the rate of wound closure. Although wound healing requires many components, sharp debridement can effectively remove devitalized tissue and is a proven significant component to advancing wound closure.

  12. Considerations for applying VARSKIN mod 2 to skin dose calculations averaged over 10 cm2.

    PubMed

    Durham, James S

    2004-02-01

    VARSKIN Mod 2 is a DOS-based computer program that calculates the dose to skin from beta and gamma contamination either directly on skin or on material in contact with skin. The default area for calculating the dose is 1 cm2. Recently, the U.S. Nuclear Regulatory Commission issued new guidelines for calculating shallow dose equivalent from skin contamination that requires the dose be averaged over 10 cm2. VARSKIN Mod 2 was not filly designed to calculate beta or gamma dose estimates averaged over 10 cm2, even though the program allows the user to calculate doses averaged over 10 cm2. This article explains why VARSKIN Mod 2 overestimates the beta dose when applied to 10 cm2 areas, describes a manual method for correcting the overestimate, and explains how to perform reasonable gamma dose calculations averaged over 10 cm2. The article also describes upgrades underway in Varskin 3.

  13. The Effect of Skin Sebum, pH, and Moisture on Demodex Infestation in Acne Vulgaris and Rosacea Patients.

    PubMed

    Turan, Nergiz; Kapıcıoğlu, Yelda; Saraç, Gülbahar

    2017-09-01

    Acne vulgaris is an inflammatory disease involving the pilosebaceous unit. Rosacea is a chronic inflammatory skin disease that affects the face in particular. This study aimed to determine if skin sebum, pH, and moisture affect the number of Demodex spp. in acne vulgaris and rosacea patients. This study focused on 30 patients each with acne vulgaris and rosacea. As a control group, 60 healthy individuals were included. In acne vulgaris patients, when compared to those with Demodex mite more than 5 /cm2 in each area, less than 5/cm2 were found to be oily, acidic, dry or very dry. However, there was no significant difference in moisture value. In patients with rosacea, the skin was acidic and dry in patients those with more than 5/cm2 Demodex mites when compared to those with demodex mite less than 5 /cm2 in patients in each of the right cheek and nose areas. There was no difference in skin oil level. The oily, acidic, dry, and very dry skin of the acne vulgaris patients and the oily, acidic, and very dry skin of the rosacea patients are factors facilitating the development of Demodex ssp.

  14. Nanostructuring effect of multi-walled carbon nanotubes on electrochemical properties of carbon foam as constructive electrode for lead acid battery

    NASA Astrophysics Data System (ADS)

    Kumar, Rajeev; Kumari, Saroj; Mathur, Rakesh B.; Dhakate, Sanjay R.

    2015-01-01

    In the present study, nanostructuring effect of multi-walled carbon nanotubes (MWCNTs) on electrochemical properties of coal tar pitch (CTP) based carbon foam (CFoam) was investigated. The different weight fractions of MWCNTs were mixed with CTP and foam was developed from the mixture of CTP and MWCNTs by sacrificial template technique and heat treated at 1,400 and 2,500 °C in inert atmosphere. These foams were characterized by scanning electron microscopy, X-ray diffraction, and potentiostat PARSTAT for cyclic voltammetry. It was observed that, bulk density of CFoam increases with increasing MWCNTs content and decreases after certain amount. The MWCNTs influence the morphology of CFoam and increase the width of ligaments as well as surface area. During the heat treatment, stresses exerting at MWCNTs/carbon interface accelerate ordering of the graphene layer which have positive effect on the electrochemical properties of CFoam. The current density increases from 475 to 675 mA/cm2 of 1,400 °C heat treated and 95 to 210 mA/cm2 of 2,500 °C heat-treated CFoam with 1 wt% MWCNTs. The specific capacitance was decreases with increasing the scan rate from 100 to 1,000 mV/s. In case of 1 % MWCNTs content CFoam the specific capacitance at the scan rate 100 mV/s was increased from 850 to 1,250 μF/cm2 and 48 to 340 μF/cm2 of CFoam heat treated at 1,400 °C and 2,500 °C respectively. Thus, the higher value surface area and current density of MWCNTs-incorporated CFoam heat treated to 1,400 °C can be suitable for lead acid battery electrode with improved charging capability.

  15. Effect of phenylephrine bolus administration on left ventricular function during postural hypotension in anesthetized patients.

    PubMed

    Goertz, A W; Schmidt, M; Lindner, K H; Seefelder, C; Georgieff, M

    1993-01-01

    To investigate the effect of intravenous (IV) phenylephrine (PHE) bolus administration on left ventricular function in patients who developed postural hypotension during isoflurane anesthesia in the head-up tilt (reverse Trendelenburg) position. Prospective "before-after" trial. Operation theater of a university medical center. 15 ASA physical status I and II patients without cardiovascular disorders. The anesthetized patients were tilted from a supine horizontal to a 30-degree reverse-Trendelenburg position. Once a steady state was achieved, PHE 3 micrograms/kg was administered as an IV bolus dose. Transesophageal echocardiography was used to assess left ventricular function. We measured blood pressure (BP); heart rate; left ventricular end-systolic and end-diastolic area, diameter, and wall thickness; and ejection time at baseline and after tilt, immediately before and for a period of 3 minutes after PHE injection. We calculated fractional area change (FAC), mean velocity of circumferential fiber shortening (mVcf), and end-systolic wall stress. Head-up tilt caused a reduction of mean arterial pressure [from 68 to 54 mmHg (mean)], end-systolic and end-diastolic left ventricular area (from 9.7 to 6.5 cm2 and from 19.2 to 13.1 cm2, respectively) and end-systolic wall stress (from 56 to 33 10(3).dyne/cm2). FAC and mVcf remained unaltered. PHE administration restored baseline values or overcompensated the changes caused by tilt. FAC slightly decreased in response to PHE (from 0.51 to 0.43), end-systolic wall stress increased to 83 10(3).dyne/cm2, and mVcf remained unchanged. PHE bolus administration effectively restored BP and cardiac filling, which were reduced after head-up tilt, without causing a relevant impairment of left ventricular function or an increase in end-systolic wall stress above the upper normal limit.

  16. Pregnancy prediction on the day of embryo transfer (Day 7) and Day 14 by measuring luteal blood flow in dairy cows.

    PubMed

    Kanazawa, Tomomi; Seki, Motohide; Ishiyama, Keiki; Kubo, Tomoaki; Kaneda, Yoshiyuki; Sakaguchi, Minoru; Izaike, Yoshiaki; Takahashi, Toru

    2016-10-01

    This study aimed to assess the suitability of luteal blood flow analyses measured by color Doppler ultrasonography (CDUS), to predict pregnancy at pre- and post-embryo transfer (ET) in dairy cows, and to compare with the established criterion like luteal size and plasma progesterone (P4) concentrations. Lactating Holstein cows (n = 65) with spontaneous (n = 34) or synchronized estrus (n = 31) were examined. Cows with a CL greater than or equal to 20 mm in diameter (n = 58) received embryo transfer on Day 7 (Day 0 = estrus). Brightness mode images were captured for calculation of the CL area, luteal cavity area, and dominant follicle area on Days 3, 5, 7, and 14. Color Doppler ultrasonography examinations were conducted to determine the blood flow area (BFA) within the CL at the maximum diameter and the time-averaged maximum velocity (TAMV) of the base of the spiral artery on the same days. Plasma P4 concentrations were determined from blood samples collected at each ultrasound examination. Pregnancy was diagnosed by an ultrasound on Day 30. There was no significant difference in the proportion of cows received embryo (91.2% vs. 87.1%, P = 0.70) and pregnancy rate (58.1% vs. 59.3%, P = 1.00) between the spontaneous estrus and synchronized groups. The BFA values of the pregnant group (n = 34) were approximately 1.42 and 1.54 times higher than those of the nonpregnant group (n = 24) on Days 7 (0.54 ± 0.04 cm(2) vs. 0.38 ± 0.02 cm(2); P < 0.01) and 14 (0.80 ± 0.23 cm(2) vs. 0.52 ± 0.22 cm(2); P < 0.01), respectively. The TAMV of the pregnant group was approximately 1.45 times higher than that of the nonpregnant group on Day 14 (57.8 ± 3.5 cm/s vs. 40.0 ± 3.3 cm/s; P < 0.01). However, no differences were found in the CL area, CL tissue area, dominant follicle area, and plasma P4 concentrations among these groups. In addition, the best logistic regression model to predict pregnancy included scores for BFA on Day 7, BFA and TAMV on Day 14. Setting the cutoff value of BFA at 0.43 cm(2) yielded the highest sensitivity (79.4%) and specificity (75.0%) on Day 7, indicating the effectiveness of using BFA data for predicting pregnancy on Day 7. Furthermore, setting the cutoff value at one obtained from a sample with BFA 0.63 cm(2) and TAMV 50.60 cm/s yielded the highest sensitivity (85.3%) and specificity (91.7%) on Day 14. In conclusion, the evaluations of BFA on Day 7, and paired BFA and TAMV on Day 14 represent reliable predictors of pregnancy in the cow. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Effect of tree line advance on carbon storage in NW Alaska

    USGS Publications Warehouse

    Wilmking, M.; Harden, J.; Tape, K.

    2006-01-01

    We investigated the size, distribution, and temporal dynamics of ecosystem carbon (C) pools in an area of recent tree line advance, northwest Alaska. Repeat aerial photographs show forest cover increased ???10% in our study area since 1949. We sampled C pools of four principal ecosystem types, tussock tundra, shrub tundra, woodland, and forest, all located on a 600-800 year old river terrace. Significant differences between ecosystem C pools, both above ground and below ground existed. Tundra sites store >22.2 kg C/m2, shrub tundra sites and woodland sites store 9.7 kg C/m2 and 14.3 kg C/m2, respectively, and forest sites store 14.4 kg C/m2. Landscape variation of total ecosystem C was primarily due to organic soil C and was secondarily due to C stored in trees. Soil C/N profiles of shrub tundra sites and woodland sites showed similarities with forest site soils at surface and tundra site soils at depth. We hypothesize that tundra systems transformed to forest systems in this area under a progression of permafrost degradation and enhanced drainage. On the basis of C pool estimates for the different ecosystem types, conversion of tundra sites to forest may have resulted in a net loss of > 7.8 kg C/m2, since aboveground C gains were more than offset by belowground C losses to decomposition in the tundra sites. Tree line advance therefore might not increase C storage in high-latitude ecosystems and thus might not, as previously suggested, act as a negative feedback to warming. Key to this hypothesis and to its projection to future climate response is the fate of soil carbon upon warming and permafrost drainage. Copyright 2006 by the American Geophysical Union.

  18. [Effects of anteriolateral thigh perforator flap and fascia lata transplantation in combination with computed tomography angiography on repair of electrical burn wounds of head with skull exposure and necrosis].

    PubMed

    Li, X Q; Wang, X; Han, Y L; Ji, G; Chen, Z H; Zhang, J; Zhu, J P; Duan, J X; He, Y J; Yang, X M; Liu, W J

    2018-05-20

    Objective: To explore the effects of anteriolateral thigh perforator flap and fascia lata transplantation in combination with computed tomography angiography (CTA) on repair of electrical burn wounds of head with skull exposure and necrosis. Methods: Seven patients with head electrical burns accompanied by skull exposure and necrosis were admitted to our burn center from March 2016 to December 2017. Head CTA was performed before the operation. The diameters of the facial artery and vein or the superficial temporal artery and vein were measured, and their locations were marked on the body surface. Preoperative CTA for flap donor sites in lower extremities were also performed to track the descending branch of the lateral circumflex femoral artery with the similar diameter as the recipient vessels on the head, and their locations were marked on the body surface. Routine wound debridement and skull drilling were performed successively. The size of the wounds after debridement ranged from 12 cm×8 cm to 20 cm×12 cm, and the areas of skull exposure ranged from 8 cm×6 cm to 15 cm×10 cm. Anteriolateral thigh perforator flaps with areas from 13 cm×9 cm to 21 cm×13 cm containing 5-10 cm long vascular pedicles were designed and dissected accordingly. The fascia lata under the flap with area from 5 cm×2 cm to 10 cm×3 cm was dissected according to the length of vascular pedicle. The fascia lata was transplanted to cover the exposed skull, and the anteriolateral thigh perforator flap was transplanted afterwards. The descending branch of the lateral circumflex femoral artery and its accompanying vein of the flap were anastomosed with superficial temporal artery and vein or facial artery and vein before the suture of flap. The flap donor sites were covered by intermediate split-thickness skin graft collected from contralateral thigh or abdomen. Results: The descending branch of the lateral circumflex femoral artery and its accompanying vein were anastomosed with superficial temporal artery and vein in six patients, while those with facial artery and vein in one patient. All the flaps survived after the operation, and no vascular crisis was observed. Wound healing was satisfactory. One patient was lost to follow up. Six patients were followed up for 6 to 10 months. The patients were bald in the head operation area with acceptable appearance. No psychiatric symptom such as headache or epileptic seizure was reported. The flap donor sites were normal in appearance. The muscle strength of the lower extremities all reached grade V. The sensation and movement of the lower extremities were normal. Conclusions: Anterolateral thigh perforator flap with fascia lata transplantation can effectively repair electrical burn wounds of head with skull exposure and necrosis. The fascia lata can be used to protect the vascular pedicle of flaps, which is beneficial to the survival of the flap. Preoperative head and lower extremities CTA can provide reference for intraoperative vascular exploration in donor site and recipient area, so as to shorten operation time.

  19. Effect of low-level laser treatment of tissue-engineered skin substitutes: contraction of collagen lattices

    NASA Astrophysics Data System (ADS)

    Ho, Gideon; Barbenel, Joseph; Grant, M. Helen

    2009-05-01

    Fibroblast-populated collagen lattices (FPCL) are widely used in tissue-engineered artificial skin substitutes, but their main drawback is that interaction of fibroblasts and matrix causes contraction of the lattice, reducing it to about 20% of its original area. The effect of low-level laser treatment (LLLT) on the behavior of 3T3 fibroblasts seeded in collagen lattices containing 20% chondroitin-6-sulphate was investigated to determine whether LLLT could control the contraction of FPCL. A He-Ne laser was used at 632.8 nm to deliver a 5-mW continuous wave with fluences from 1 to 4 J/cm2. Laser treatment at 3 J/cm2 increased contraction of collagen lattices in the absence of cells but decreased contraction of cell seeded lattices over a 7-day period. The effect was energy dependent and was not observed at 1, 2, or 4 J/cm2. There was no alteration in fibroblast viability, morphology, or mitochondrial membrane potential after any laser treatments, but the distribution of actin fibers within the cells and collagen fibers in the matrices was disturbed at 3 J/cm2. These effects contribute to the decrease in contraction observed. LLLT may offer a means to control contraction of FPCL used as artificial skin substitutes.

  20. Effects of topography on simulated net primary productivity at landscape scale.

    PubMed

    Chen, X F; Chen, J M; An, S Q; Ju, W M

    2007-11-01

    Local topography significantly affects spatial variations of climatic variables and soil water movement in complex terrain. Therefore, the distribution and productivity of ecosystems are closely linked to topography. Using a coupled terrestrial carbon and hydrological model (BEPS-TerrainLab model), the topographic effects on the net primary productivity (NPP) are analyzed through four modelling experiments for a 5700 km(2) area in Baohe River basin, Shaanxi Province, northwest of China. The model was able to capture 81% of the variability in NPP estimated from tree rings, with a mean relative error of 3.1%. The average NPP in 2003 for the study area was 741 gCm(-2)yr(-1) from a model run including topographic effects on the distributions of climate variables and lateral flow of ground water. Topography has considerable effect on NPP, which peaks near 1350 m above the sea level. An elevation increase of 100 m above this level reduces the average annual NPP by about 25 gCm(-2). The terrain aspect gives rise to a NPP change of 5% for forests located below 1900 m as a result of its influence on incident solar radiation. For the whole study area, a simulation totally excluding topographic effects on the distributions of climatic variables and ground water movement overestimated the average NPP by 5%.

  1. High-Rate Capable Floating Strip Micromegas

    NASA Astrophysics Data System (ADS)

    Bortfeldt, Jonathan; Bender, Michael; Biebel, Otmar; Danger, Helge; Flierl, Bernhard; Hertenberger, Ralf; Lösel, Philipp; Moll, Samuel; Parodi, Katia; Rinaldi, Ilaria; Ruschke, Alexander; Zibell, André

    2016-04-01

    We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in high-background environments and at very high particle fluxes up to 60 MHz/cm2. Measurement and simulation of the microscopic discharge behavior have demonstrated the excellent discharge tolerance. A floating strip Micromegas with an active area of 48 cm × 50 cm with 1920 copper anode strips exhibits in 120 GeV pion beams a spatial resolution of 50 μm at detection efficiencies above 95%. Pulse height, spatial resolution and detection efficiency are homogeneous over the detector. Reconstruction of particle track inclination in a single detector plane is discussed, optimum angular resolutions below 5° are observed. Systematic deviations of this μTPC-method are fully understood. The reconstruction capabilities for minimum ionizing muons are investigated in a 6.4 cm × 6.4 cm floating strip Micromegas under intense background irradiation of the whole active area with 20 MeV protons at a rate of 550 kHz. The spatial resolution for muons is not distorted by space charge effects. A 6.4 cm × 6.4 cm floating strip Micromegas doublet with low material budget is investigated in highly ionizing proton and carbon ion beams at particle rates between 2 MHz and 2 GHz. Stable operation up to the highest rates is observed, spatial resolution, detection efficiencies, the multi-hit and high-rate capability are discussed.

  2. Effect of obstructive sleep apnea on mitral valve tenting.

    PubMed

    Pressman, Gregg S; Figueredo, Vincent M; Romero-Corral, Abel; Murali, Ganesan; Kotler, Morris N

    2012-04-01

    Obstructive apneas produce high negative intrathoracic pressure that imposes an afterload burden on the left ventricle. Such episodes might produce structural changes in the left ventricle over time. Doppler echocardiograms were obtained within 2 months of attended polysomnography. Patients were grouped according to apnea-hypopnea index (AHI): mild/no obstructive sleep apnea (OSA; AHI <15) and moderate/severe OSA (AHI ≥15). Mitral valve tenting height and area, left ventricular (LV) long and short axes, and LV end-diastolic volume were measured in addition to tissue Doppler parameters. Comparisons of measurements at baseline and follow-up between and within groups were obtained; correlations between absolute changes (Δ) in echocardiographic parameters were also performed. After a mean follow-up of 240 days mitral valve tenting height increased significantly (1.17 ± 0.12 to 1.28 ± 0.17 cm, p = 0.001) in moderate/severe OSA as did tenting area (2.30 ± 0.41 to 2.66 ± 0.60 cm(2), p = 0.0002); Δtenting height correlated with ΔLV end-diastolic volume (rho 0.43, p = 0.01) and Δtenting area (rho 0.35, p = 0.04). In patients with mild/no OSA there was no significant change in tenting height; there was a borderline significant increase in tenting area (2.20 ± 0.44 to 2.31 ± 0.43 cm(2), p = 0.05). Septal tissue Doppler early diastolic wave decreased (8.04 ± 2.49 to 7.10 ± 1.83 cm/s, p = 0.005) in subjects with moderate/severe OSA but not in in those with mild/no OSA. In conclusion, in patients with moderate/severe OSA, mitral valve tenting height and tenting area increase significantly over time. This appears to be related, at least in part, to changes in LV geometry. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Soft x-ray free-electron laser induced damage to inorganic scintillators

    DOE PAGES

    Burian, Tomáš; Hájková, Věra; Chalupský, Jaromír; ...

    2015-01-07

    An irreversible response of inorganic scintillators to intense soft x-ray laser radiation was investigated at the FLASH (Free-electron LASer in Hamburg) facility. Three ionic crystals, namely, Ce:YAG (cerium-doped yttrium aluminum garnet), PbWO4 (lead tungstate), and ZnO (zinc oxide), were exposed to single 4.6 nm ultra-short laser pulses of variable pulse energy (up to 12 μJ) under normal incidence conditions with tight focus. Damaged areas produced with various levels of pulse fluences, were analyzed on the surface of irradiated samples using differential interference contrast (DIC) and atomic force microscopy (AFM). The effective beam area of 22.2 ± 2.2 μm2 was determinedmore » by means of the ablation imprints method with the use of poly(methyl methacrylate) - PMMA. Applied to the three inorganic materials, this procedure gave almost the same values of an effective area. The single-shot damage threshold fluence was determined for each of these inorganic materials. The Ce:YAG sample seems to be the most radiation resistant under the given irradiation conditions, its damage threshold was determined to be as high as 660.8 ± 71.2 mJ/cm2. Contrary to that, the PbWO4 sample exhibited the lowest radiation resistance with a threshold fluence of 62.6 ± 11.9 mJ/cm2. The threshold for ZnO was found to be 167.8 ± 30.8 mJ/cm2. Both interaction and material characteristics responsible for the damage threshold difference are discussed in the article.« less

  4. Evaluation of Chemical Warfare Agent Wipe Sampling ...

    EPA Pesticide Factsheets

    Report This investigation tested specific (CWAs), including sarin (GB), soman (GD), cyclosarin (GF), sulfur mustard (HD), and O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate (VX) on the non-ideal (e.g., porous and permeable) surfaces of drywall, vinyl tile, wood, laminate, and coated glass. Pesticides (diazinon and malathion) were used so that a comparison is possible with existing literature data (1). Experiments included testing with coupons having surface areas of 10 cm2 and 100 cm2. The 10-cm2 coupons were of a size that could easily be extracted in a 2 oz jar (to provide comparative data for CWA recoveries generated by direct extraction) and the 100-cm2 coupons better represented the area of a surface that might typically be sampled by wipe extraction. In addition, CWA, at a normalized surface concentration of 0.1 µg per cm2 surface area, were spiked on coupons of the tested surfaces. Wipes were wetted with either dichloromethane (DCM) or isopropanol (IPA) before sampling for CWA. Experimental parameters include multiple wipe types, porous/permeable surfaces, coupon surface area, solvent used to wet the wipe (i.e., wetting solvent), and the utility of VX-d14 as an extracted internal standard.

  5. Effect of load, area of contact, and contact stress on the wear mechanisms of a bonded solid lubricant film

    NASA Technical Reports Server (NTRS)

    Fusaro, R. L.

    1980-01-01

    A pin on disk type of friction and wear apparatus was used to study the effect of load, contact stress and rider area of contact on the friction and wear properties of polyimide bonded graphite fluoride films. Different rider area contacts were obtained by initially generating flats (with areas of 0.0035, 0.0071, 0.0145, and 0.0240 cm) on 0.476-cm radius hemispherically tipped riders. Different projected contact stresses were obtained by applying loads of 2.5- to 58.8-N to the flats. Two film wear mechanisms were observed. The first was found to be a linear function of contact stress and was independent of rider area of contact. The second was found to increase exponentially as the stress increased. The second also appeared to be a function of rider contact area. Wear equations for each mechanism were empirically derived from the experimental data. In general, friction coefficients increased with increasing rider contact area and with sliding duration. This was related to the build up of thick rider transfer films.

  6. Effect of load, area of contact, and contact stress on the tribological properties of polyimide bonded graphite fluoride films

    NASA Technical Reports Server (NTRS)

    Fusaro, R. L.

    1981-01-01

    A pin-on-disk type of friction and wear apparatus was used to study the effect of load, contact stress and rider area of contact on the friction and wear properties of polyimide-bonded graphite fluoride films. Different rider area contacts were obtained by initially generating flats (with areas of 0.0035, 0.0071, 0.0145, and 0.0240 cm) on 0.476-cm radius hemispherically-tipped riders. Different projected contact stresses were obtained by applying loads of 2.5-to 58.8-N to the flats. Two film wear mechanisms were observed. The first was found to be a linear function of contact stress and was independent of rider area of contact. The second was found to increase exponentially as the stress increased. The second also appeared to be a function of rider contact area. Wear equations for each mechanism were empirically derived from the experimental data. In general, friction coefficients increased with increasing rider contact area and with sliding duration. This was related to the build-up of thick rider transfer films.

  7. Automated array assembly, phase 2

    NASA Technical Reports Server (NTRS)

    Carbajal, B. G.

    1979-01-01

    Tasks of scaling up the tandem junction cell (TJC) from 2 cm x 2 cm to 6.2 cm and the assembly of several modules using these large area TJC's are described. The scale-up of the TJC was based on using the existing process and doing the necessary design activities to increase the cell area to an acceptably large area. The design was carried out using available device models. The design was verified and sample large area TJCs were fabricated. Mechanical and process problems occurred causing a schedule slippage that resulted in contract expiration before enough large-area TJCs were fabricated to populate the sample tandem junction modules (TJM). A TJM design was carried out in which the module interconnects served to augment the current collecting buses on the cell. No sample TJMs were assembled due to a shortage of large-area TJCs.

  8. Climate and land use changes effects on soil organic carbon stocks in a Mediterranean semi-natural area.

    PubMed

    Lozano-García, Beatriz; Muñoz-Rojas, Miriam; Parras-Alcántara, Luis

    2017-02-01

    A thorough knowledge of the effects of climate and land use changes on the soil carbon pool is critical to planning effective strategies for adaptation and mitigation in future scenarios of global climate and land use change. In this study, we used CarboSOIL model to predict changes in soil organic carbon stocks in a semi-natural area of Southern Spain in three different time horizons (2040, 2070, 2100), considering two general circulation models (BCM2 and ECHAM5) and three IPCC scenarios (A1b, A2, B2). The effects of potential land use changes from natural vegetation (Mediterranean evergreen oak woodland) to agricultural land (olive grove and cereal) on soil organic carbon stocks were also evaluated. Predicted values of SOC contents correlated well those measured (R2 ranging from 0.71 at 0-25cm to 0.97 at 50-75cm) showing the efficiency of the model. Results showed substantial differences among time horizons, climate and land use scenarios and soil depth with larger decreases of soil organic carbon stocks in the long term (2100 time horizon) and particularly in olive groves. The combination of climate and land use scenarios (in particular conversion from current 'dehesa' to olive groves) resulted in yet higher losses of soil organic carbon stocks, e.g. -30, -15 and -33% in the 0-25, 25-50 and 50-75cm sections respectively. This study shows the importance of soil organic carbon stocks assessment under both climate and land use scenarios at different soil sections and point towards possible directions for appropriate land use management in Mediterranean semi natural areas. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Hemocompatibility Comparison of Biomedical Grade Polymers Using Rabbit Thrombogenicity Model for Preparing Nonthrombogenic Nitric Oxide Releasing Surfaces

    PubMed Central

    Handa, Hitesh; Major, Terry C.; Brisbois, Elizabeth J.; Amoako, Kagya A.; Meyerhoff, Mark E.; Bartlett, Robert H.

    2014-01-01

    Nitric oxide (NO) is an endogenous vasodilator as well as natural inhibitor of platelet adhesion/activation. Nitric oxide releasing (NOrel) materials can be prepared by doping an NO donor species, such as diazeniumdiolated dibutylhexanediamine (DBHD/N2O2), within a polymer coating. The inherent hemocompatibility properties of the base polymer can also influence the efficiency of such NO release coatings. In this study, four biomedical grade polymers were evaluated in a 4 h rabbit model of thrombogenicity for their effects on extracorporeal circuit thrombus formation and circulating platelet count. At the end of 4 h, Elast-Eon E2As was found to preserve 58% of baseline platelets versus 48, 40, and 47% for PVC/DOS, Tecophilic SP-60D-60, and Tecoflex SG80A, respectively. Elast-Eon also had significantly lower clot area of 5.2 cm2 compared to 6.7, 6.1, and 6.9 cm2 for PVC/DOS, SP-60D-60, and SG80A, respectively. Based on the results obtained for the base polymer comparison study, DBHD/N2O2-doped E2As was evaluated in short-term (4 h) rabbit studies to observe the NO effects on prevention of clotting and preservation of platelet function. Platelet preservation for this optimal NO release formulation was 97% of baseline after 4 h, and clot area was 0.9 cm2 compared to 5.2 cm2 for controls, demonstrating that combining E2As with NO release provides a truly advanced hemocompatible polymer coating for extracorporeal circuits and potentially other blood contacting applications. PMID:24634777

  10. Feasibility of using a dose-area product ratio as beam quality specifier for photon beams with small field sizes.

    PubMed

    Pimpinella, Maria; Caporali, Claudio; Guerra, Antonio Stefano; Silvi, Luca; De Coste, Vanessa; Petrucci, Assunta; Delaunay, Frank; Dufreneix, Stéphane; Gouriou, Jean; Ostrowsky, Aimé; Rapp, Benjamin; Bordy, Jean-Marc; Daures, Josiane; Le Roy, Maïwenn; Sommier, Line; Vermesse, Didier

    2018-01-01

    To investigate the feasibility of using the ratio of dose-area product at 20 cm and 10 cm water depths (DAPR 20,10 ) as a beam quality specifier for radiotherapy photon beams with field diameter below 2 cm. Dose-area product was determined as the integral of absorbed dose to water (D w ) over a surface larger than the beam size. 6 MV and 10 MV photon beams with field diameters from 0.75 cm to 2 cm were considered. Monte Carlo (MC) simulations were performed to calculate energy-dependent dosimetric parameters and to study the DAPR 20,10 properties. Aspects relevant to DAPR 20,10 measurement were explored using large-area plane-parallel ionization chambers with different diameters. DAPR 20,10 was nearly independent of field size in line with the small differences among the corresponding mean beam energies. Both MC and experimental results showed a dependence of DAPR 20,10 on the measurement setup and the surface over which D w is integrated. For a given setup, DAPR 20,10 values obtained using ionization chambers with different air-cavity diameters agreed with one another within 0.4%, after the application of MC correction factors accounting for effects due to the chamber size. DAPR 20,10 differences among the small field sizes were within 1% and sensitivity to the beam energy resulted similar to that of established beam quality specifiers based on the point measurement of D w . For a specific measurement setup and integration area, DAPR 20,10 proved suitable to specify the beam quality of small photon beams for the selection of energy-dependent dosimetric parameters. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. Transperineal ultrasound in the assessment of haemorrhoids and haemorrhoidectomy: a pilot study.

    PubMed

    Zbar, A P; Murison, R

    2010-06-01

    The purpose of the study was the measurement of the anal cushion area using static transperineal ultrasound in a group of patients with symptomatic grade III and IV haemorrhoids about to undergo haemorrhoidectomy and compare them with a group of age-matched normals and the measured area following haemorrhoidectomy. Transperineal sonography was performed using a linear transducer measuring the anal cushion area by subtracting the measured luminal diameter of the undisturbed anal canal from the inner border of the internal anal sphincter. Measures were made 6 weeks following haemorrhoidectomy. Comparisons were made between 22 normals and 36 patients with haemorrhoids (31 evaluable post-operatively). The median area of normals was 0.78 cm², that of pre-operative patients 2.25 cm² and that of post-operative cases 1.20 cm². There was a significant difference between pre- and post-operative cases with cushion areas of normal patients being significantly lower than post-operative cases. Variance of measurement in all 3 groups was negligible. Static transperineal sonography measuring the anal cushion area is reproducible and shows marked differences between normals and patients with symptomatic haemorrhoids. There is a marked effect on measured area resultant from haemorrhoidectomy.

  12. Fabrication and electrochemical properties of hemisphere structured 3D Li(Li0.2Mn0.54Co0.13Ni0.13)O2 cathode thin film for all-solid-state lithium battery.

    PubMed

    Yim, H; Kong, W Y; Yoon, S J; Kim, Y C; Choi, J W

    2013-05-01

    The Li[Li0.2Mn0.54Ni0.13Co0.13]O2 cathode thin films were deposited on planar, hemisphere, linked hemisphere, and isolated hemisphere structured Pt current collector thin films to investigate the effect of 3-dimensional (3-D) structure for the electrochemical properties of active cathode thin films. The films of linked hemisphere structure shows the highest initial discharge capacity of 140 microA h/cm2-microm which is better than those of planar (62 microA h/cm2-microm), hemisphere (94.6 microA h/cm2-microm), and isolated hemisphere (135 microA h/cm2-microm) films due to increase of surface area for cathode thin films. Linked hemisphere shows the biggest capacity and the best retention rate because 6 nanobridges of each hemisphere bring strong connection.

  13. Schottky barrier diode and method thereof

    NASA Technical Reports Server (NTRS)

    Aslam, Shahid (Inventor); Franz, David (Inventor)

    2008-01-01

    Pt/n.sup.-GaN Schottky barrier diodes are disclosed that are particularly suited to serve as ultra-violet sensors operating at wavelengths below 200 nm. The Pt/n.sup.-GaN Schottky barrier diodes have very large active areas, up to 1 cm.sup.2, which exhibit extremely low leakage current at low reverse biases. Very large area Pt/n.sup.-GaN Schottky diodes of sizes 0.25 cm.sup.2 and 1 cm.sup.2 have been fabricated from n.sup.-/n.sup.+ GaN epitaxial layers grown by vapor phase epitaxy on single crystal c-plane sapphire, which showed leakage currents of 14 pA and 2.7 nA, respectively for the 0.25 cm.sup.2 and 1 cm.sup.2 diodes both configured at a 0.5V reverse bias.

  14. Carboxymethyl Cellulose, Trichloroacetic Acid, and Unna Boot for Healing Venous Ulcers: A Comparative Study of Their Efficacy and Socioeconomic Impact.

    PubMed

    Carneiro, Sueli; Januário, Virginia; Oliveira, Maria Leide W; de Oliveira Teixeira, Maria Luiza; Maciel, Solange; Macedo, João Carlos; Ramos-E-Silva, Marcia

    2017-01-01

    Chronic ulcers are defined as a breakdown of the long-term cutaneous barrier or frequent recurrence of breakdowns. Dressings are a form of treatment and, in view of the variety and high cost of the products on the market, three agents were selected for this investigation, regarding their efficacy and cost/benefit ratio. The objective of the investigation was to evaluate and compare the efficacy, costs, and benefits of carboxymethylcellulose in paste at 20% (CMC 20%), trichloroacetic acid at 90% (TCA 90%), and Unna boot for treatment of chronic venous ulcers. Three groups of 30 patients each were chosen randomly for ambulatory treatment with TCA 90% (G1), CMC 20% (G2), and Unna boot (G3). The evolution of the cicatricial process of each group separately and between groups was analyzed with measurement of the lesion areas in square centimeters (cm2) and observation of the amount of exudate from observation of the photographic record, until their healing, in the maximum period of 20 weeks. A significant reduction of lesion areas in all groups was observed ( P =.0001), with a median reduction of 7.6 cm 2 (38.1%) for G1, 3.9 cm 2 (38.8%) for G2, and 16.2 cm 2 (77.8%) for G3. There was a significant difference in the absolute delta of the lesion areas ( P =.0001) of the groups. The three types of treatments promoted effective improvement, with acquisition and utilization of all three products in the public health services being recommended.

  15. Optimizing Hill Seeding Density for High-Yielding Hybrid Rice in a Single Rice Cropping System in South China

    PubMed Central

    Wang, Danying; Chen, Song; Wang, Zaiman; Ji, Chenglin; Xu, Chunmei; Zhang, Xiufu; Chauhan, Bhagirath Singh

    2014-01-01

    Mechanical hill direct seeding of hybrid rice could be the way to solve the problems of high seeding rates and uneven plant establishment now faced in direct seeded rice; however, it is not clear what the optimum hill seeding density should be for high-yielding hybrid rice in the single-season rice production system. Experiments were conducted in 2010 and 2011 to determine the effects of hill seeding density (25 cm×15 cm, 25 cm×17 cm, 25 cm×19 cm, 25 cm×21 cm, and 25 cm×23 cm; three to five seeds per hill) on plant growth and grain yield of a hybrid variety, Nei2you6, in two fields with different fertility (soil fertility 1 and 2). In addition, in 2012 and 2013, comparisons among mechanical hill seeding, broadcasting, and transplanting were conducted with three hybrid varieties to evaluate the optimum seeding density. With increases in seeding spacing from 25 cm×15 cm to 25 cm×23 cm, productive tillers per hill increased by 34.2% and 50.0% in soil fertility 1 and 2. Panicles per m2 declined with increases in seeding spacing in soil fertility 1. In soil fertility 2, no difference in panicles per m2 was found at spacing ranging from 25 cm×17 cm to 25 cm×23 cm, while decreases in the area of the top three leaves and aboveground dry weight per shoot at flowering were observed. Grain yield was the maximum at 25 cm×17 cm spacing in both soil fertility fields. Our results suggest that a seeding density of 25 cm×17 cm was suitable for high-yielding hybrid rice. These results were verified through on-farm demonstration experiments, in which mechanical hill-seeded rice at this density had equal or higher grain yield than transplanted rice. PMID:25290342

  16. Large-area high-efficiency flexible PHOLED lighting panels

    NASA Astrophysics Data System (ADS)

    Pang, Huiqing; Mandlik, Prashant; Levermore, Peter A.; Silvernail, Jeff; Ma, Ruiqing; Brown, Julie J.

    2012-09-01

    Organic Light Emitting Diodes (OLEDs) provide various attractive features for next generation illumination systems, including high efficiency, low power, thin and flexible form factor. In this work, we incorporated phosphorescent emitters and demonstrated highly efficient white phosphorescent OLED (PHOLED) devices on flexible plastic substrates. The 0.94 cm2 small-area device has total thickness of approximately 0.25 mm and achieved 63 lm/W at 1,000 cd/m2 with CRI = 85 and CCT = 2920 K. We further designed and fabricated a 15 cm x 15 cm large-area flexible white OLED lighting panels, finished with a hybrid single-layer ultra-low permeability single layer barrier (SLB) encapsulation film. The flexible panel has an active area of 116.4 cm2, and achieved a power efficacy of 47 lm/W at 1,000 cd/m2 with CRI = 83 and CCT = 3470 K. The efficacy of the panel at 3,000 cd/m2 is 43 lm/W. The large-area flexible PHOLED lighting panel is to bring out enormous possibilities to the future general lighting applications.

  17. Three-dimensional Evaluation of Nasal Surgery in Patients with Obstructive Sleep Apnea.

    PubMed

    Cui, Dan-Mo; Han, De-Min; Nicolas, Busaba; Hu, Chang-Long; Wu, Jun; Su, Min-Min

    2016-03-20

    Obstructive sleep apnea (OSA) is a common sleep disorder and is characterized by airway collapse at multiple levels of upper airway. The effectiveness of nasal surgery has been discussed in several studies and shows a promising growing interest. In this study, we intended to evaluate the effects of nasal surgery on the upper airway dimensions in patients with OSA using three-dimensional (3D) reconstruction of cone-beam computed tomography (CT). Twelve patients with moderate to severe OSA who underwent nasal surgery were included in this study. All patients were diagnosed with OSA using polysomnography (PSG) in multi sleep health centers associated with Massachusetts General Hospital, Massachusetts Eye and Ear Infirmary and the Partners Health Care from May 31, 2011 to December 14, 2013. The effect of nasal surgery was evaluated by the examination of PSG, subjective complains, and 3D reconstructed CT scan. Cross-sectional area was measured in eleven coronal levels, and nasal cavity volume was evaluated from anterior nasal spine to posterior nasal spine. The thickness of soft tissue in oral pharynx region was also measured. Five out of the 12 patients were successfully treated by nasal surgery, with more than 50% drop of apnea-hypopnea index. All the 12 patients showed significant increase of cross-sectional area and volume postoperatively. The thickness of soft tissue in oral pharynx region revealed significant decrease postoperatively, which decreased from 19.14 ± 2.40 cm 2 and 6.11 ± 1.76 cm 2 to 17.13 ± 1.91 cm 2 and 5.22 ± 1.20 cm 2 . Nasal surgery improved OSA severity as measured by PSG, subjective complaints, and 3D reconstructed CT scan. 3D assessment of upper airway can play an important role in the evaluation of treatment outcome.

  18. Glove use among hairdressers: difficulties in the correct use of gloves among hairdressers and the effect of education.

    PubMed

    Oreskov, Katia W; Søsted, Heidi; Johansen, Jeanne D

    2015-06-01

    Hand eczema is frequent among Danish hairdressers, and they are advised to use gloves as protection. However, studies indicate that a significant proportion use gloves inappropriately. To determine whether hairdressers and apprentices use protective gloves in the correct way, and to determine whether a demonstration of correct use could cause an improvement. Forty-three hairdressers and apprentices were asked to perform a hair wash while wearing gloves. The shampoo used was contaminated with an ultraviolet (UV) trace material. Two rounds of hair washing were carried out by each person, interrupted by a demonstration of how to use gloves correctly. Photographs were taken to compare UV contamination before and after the demonstration. All of the participants (100%) had their hands contaminated during the first round; the area ranged between 0.02 and 101.37 cm(2) (median 3.62 cm(2)). In the second round, 55.8% were contaminated (range 0.00-3.08 cm(2) ; median 0.01 cm(2)). The reduction in contaminated skin areas was statistically significant (p < 0.001), proving an effect of the glove demonstration. There were no significant differences between hairdressers and apprentices. Hairdressers and apprentices lack knowledge on how to handle gloves correctly. A short demonstration of correct glove use made a significant difference in the skin protection provided by gloves. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Chronic Pseudomonas aeruginosa infection and respiratory muscle impairment in cystic fibrosis.

    PubMed

    Dassios, Theodore G; Katelari, Anna; Doudounakis, Stavros; Dimitriou, Gabriel

    2014-03-01

    Chronic infection with Pseudomonas aeruginosa in patients with cystic fibrosis (CF) is associated with increased morbidity. Chronic infection can cause limb and respiratory muscle compromise. Respiratory muscle function can be assessed via maximal inspiratory pressure (PImax), maximal expiratory pressure (PEmax), and the pressure-time index of the respiratory muscles (PTImus). We studied the effect of chronic P. aeruginosa infection on respiratory muscle function in patients with CF. This cross-sectional study assessed PImax, PEmax, PTImus, FEV1, FVC, maximum expiratory flow during the middle half of the FVC maneuver, body mass index, and upper arm muscle area in 122 subjects with CF, in 4 subgroups matched for age and sex at different stages of P. aeruginosa infection, according to the Leeds criteria. We compared respiratory muscle function in the subgroups according to P. aeruginosa infection state. Median PImax was significantly lower in CF subjects with chronic P. aeruginosa infection (PImax = 62 cm H2O), compared to subjects who were never infected (PImax = 86 cm H2O, P = .02), free of infection (PImax = 74 cm H2O, P = .01), or intermittently infected (PImax = 72 cm H2O, P = .02). Median PTImus was significantly increased in CF subjects with chronic P. aeruginosa infection (PTImus = .142), compared to subjects who were free of infection (PTImus = .102, P = .006). Median upper-arm muscle area was significantly lower in CF subjects with chronic P. aeruginosa infection (upper-arm muscle area = 2,219 mm(2)), compared to subjects who were never infected (2,754 mm(2), P = .03), free of infection (2,678 mm(2), P = .01), or intermittently infected (2,603 mm(2), P = .04). Multivariate logistic regression revealed P. aeruginosa state of infection as a significant determinant of PTImus (P = .03) independently of sex, upper-arm muscle area, and FEV1. CF subjects with chronic P. aeruginosa infection exhibited impaired respiratory muscle function and decreased inspiratory muscle strength, and chronic P. aeruginosa infection independently impacts respiratory muscle function in subjects with CF.

  20. [Repair of cervical postradiation ulcer following radical mastectomy with lower trapezius myocutaneous flap].

    PubMed

    Ning, Fanggang; Qin, Fengjun; Chen, Xin; Zhang, Guoan

    2015-12-01

    To explore the clinical effects of ipsilateral lower trapezius myocutaneous flap for repairing cervical ulcer as a result of radiotherapy after radical mastectomy. Six patients with cervical ulcers as a result of radiotherapy after radical mastectomy were hospitalized from March 2010 to February 2015, suffering from persistent pain in different degrees. The wound area ranged from 6 cm × 4 cm to 10 cm × 6 cm before debridement, 8 cm × 5 cm to 16 cm × 10 cm after debridement. Ipsilateral lower trapezius myocutaneous flap was used to repair the wound after thorough debridement, with the area ranging from 10 cm × 7 cm to 20 cm × 13 cm. The donor sites were sutured directly or covered with medium-thickness skin graft obtained from the back. Pain was obviously relieved in all the patients 2 days after surgery. The wounds in five patients were healed, while necrosis of superficial skin approximately 1 cm in diameter appeared at the distal end of one myocutaneous flap, and it healed after dressing change. During the follow-up period of 3 to 18 months, no recurrence of ulcer was found, the texture of the myocutaneous flaps was soft with good appearance, and the donor sites healed well. On the basis of thorough debridement, it is feasible to repair the cervical ulcer as a result of radiotherapy after radical mastectomy with the ipsilateral lower trapezius myocutaneous flap.

  1. Determination of the amount of physical adsorption of water vapour on platinum-iridium surfaces

    NASA Astrophysics Data System (ADS)

    Mizushima, S.; Ueda, K.; Ooiwa, A.; Fujii, K.

    2015-08-01

    This paper presents the measurement of the physical adsorption of water vapour on platinum-iridium surfaces using a vacuum mass comparator. This value is of importance for redefining the kilogram, which will be realized under vacuum in the near future. Mirror-polished artefacts, consisting of a reference artefact and a test artefact, were manufactured for this experiment. The surface area difference between the reference and test artefacts was 226.2 cm2. This surface area difference was approximately 3.2 times the geometric surface area of the prototype of the kilogram made of platinum-iridium (71.7 cm2). The measurement results indicate that the amount of physical adsorption at a relative humidity of 50% is 0.0129 μg cm{{-}2} , with a standard uncertainty of 0.0016 μg cm{{-}2} . This value is 0.03 to 0.16 times that observed in other studies.

  2. Impact of sampling area and location on measurement of indicator organisms during beef carcass interventions

    USDA-ARS?s Scientific Manuscript database

    The effect of sponge sample collection site on the recovery of multiple indicator organisms from beef carcass surfaces was evaluated. Two 4,000 cm2 samples were collected from pre-evisceration carcasses (n=248), one from the inside and outside round area (top site) and one from the navel-plate-bris...

  3. Ethnic Differences in Mammographic Densities: An Asian Cross-Sectional Study

    PubMed Central

    Mariapun, Shivaani; Li, Jingmei; Yip, Cheng Har; Taib, Nur Aishah Mohd; Teo, Soo-Hwang

    2015-01-01

    Background Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. Methods A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. Results Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0%) compared to Malay (24.2%; 95% CI 22.5%, 26.0%) and Indian (24.3%; 95% CI 22.8%, 25.7%) women (p<0.001), after adjustment for age, BMI, menopausal status, parity and age at first full term pregnancy. Correspondingly, adjusted nondense area was significantly lower in Chinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2) women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2) and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2) women (p<0.001), but dense area did not differ across the three ethnic groups. Conclusions Our study shows that higher percent density and lower nondense area reflect the higher incidence of breast cancer in Chinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort. PMID:25659139

  4. Ethnic differences in mammographic densities: an Asian cross-sectional study.

    PubMed

    Mariapun, Shivaani; Li, Jingmei; Yip, Cheng Har; Taib, Nur Aishah Mohd; Teo, Soo-Hwang

    2015-01-01

    Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0%) compared to Malay (24.2%; 95% CI 22.5%, 26.0%) and Indian (24.3%; 95% CI 22.8%, 25.7%) women (p<0.001), after adjustment for age, BMI, menopausal status, parity and age at first full term pregnancy. Correspondingly, adjusted nondense area was significantly lower in Chinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2) women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2) and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2) women (p<0.001), but dense area did not differ across the three ethnic groups. Our study shows that higher percent density and lower nondense area reflect the higher incidence of breast cancer in Chinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort.

  5. Large-area thin self-supporting carbon foils with MgO coatings

    NASA Astrophysics Data System (ADS)

    Stolarz, Anna; Maier-Komor, Peter

    2002-03-01

    Large area self-supporting carbon foils in the thickness of range of 8-22 μg/cm 2, coated with approximately 4 μg/cm 2 MgO have been prepared by e-gun evaporation. They were mounted on frames with apertures of 130 cm 2. Problems related to the parting agent preparation, floating procedure, and mounting onto frames are discussed. Special precautions necessary to avoid damage during foil drying, storage and transportation are suggested.

  6. Electrical Stimulation During Gait Promotes Increase of Muscle Cross-sectional Area in Quadriplegics: A Preliminary Study

    PubMed Central

    Cliquet, Alberto; Rondina, Jane Maryan; Cendes, Fernando

    2008-01-01

    Increases in muscular cross-sectional area (CSA) occur in quadriplegics after training, but the effects of neuromuscular electrical stimulation (NMES) along with training are unknown. Thus, we addressed two questions: (1) Does NMES during treadmill gait training increase the quadriceps CSA in complete quadriplegics?; and (2) Is treadmill gait training alone enough to observe an increase in CSA? Fifteen quadriplegics were divided into gait (n = 8) and control (n = 7) groups. The gait group performed training with NMES for 6 months twice a week for 20 minutes each time. After 6 months of traditional therapy, the control group received the same gait training protocol but without NMES for an additional 6 months. Axial images of the thigh were acquired at the beginning of the study, at 6 months (for both groups), and at 12 months for the control group to determine the average quadriceps CSA. After 6 months, there was an increase of CSA in the gait group (from 49.8 ± 9.4 cm2 to 57.3 ± 10.3 cm2), but not in the control group (from 43.6 ± 7.6 cm2 to 41.8 ± 8.4 cm2). After another 6 months of gait without NMES in the control group, the CSA did not change (from 41.8 ± 8.4 cm2 to 41.7 ± 7.9 cm2). The increase in quadriceps CSA after gait training in patients with chronic complete quadriplegia appears associated with NMES. PMID:18791775

  7. Electrochemotherapy under tumescent local anesthesia for the treatment of cutaneous metastases.

    PubMed

    Kendler, Michael; Micheluzzi, Martin; Wetzig, Tino; Simon, Jan C

    2013-07-01

    The surgical management of cutaneous metastasis (CM) is challenging, particularly in elderly patients, in whom general anesthesia can be difficult because of comorbidity. To test the effectiveness of tumescent local anesthesia (TLA) to achieve adequate anesthesia during the treatment of extensive CM with electrochemotherapy (ECT), previously only performed under general anesthesia. We conducted five ECT treatments of CM with intralesional bleomycin under TLA. We examined pain scores before, during, and after treatment; analgesic use; and side effects. The intention of the treatment was palliative in all cases. We treated four patients (ages 75-88) with CM with a mean area of 126 cm(2) (range 12-198 cm(2) ) with 356 mL of TLA per treatment (range 180-450 mL). The ECT treatment under TLA demonstrated that anesthesia was adequate, with moderate pain during and slight pain after the procedure as measured on a visual analog scale (VAS). In this proof-of-principle study, we demonstrated that ECT can be performed under TLA; TLA might be a useful new anesthesia option for patients treated with ECT. © 2013 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  8. A new large area scintillator screen for X-ray imaging

    NASA Astrophysics Data System (ADS)

    Nagarkar, V. V.; Miller, S. R.; Tipnis, S. V.; Lempicki, A.; Brecher, C.; Lingertat, H.

    2004-01-01

    We report on the development of a new, large area, powdered scintillator screen based on Lu 2O 3(Eu). As reported earlier, the transparent ceramic form of this material has a very high density of 9.4 g/cm 3, a high light output comparable to that of CsI(Tl), and emits in a narrow spectral band centered at about 610 nm. Research into fabrication of this ceramic scintillator in a large area format is currently underway, however the process is not yet practical for large scale production. Here we have explored fabrication of large area screens using precursor powders from which the ceramics are fabricated. To date we have produced up to 16 × 16 cm 2 area screens with thickness in the range of 18 mg/cm 2. This paper outlines the screen fabrication technique and presents its imaging performance in comparison with a commercial Gd 2O 2S:Tb (GOS) screen.

  9. [Effects of simulated nitrogen deposition on soil microbial biomass carbon and nitrogen in natural evergreen broad-leaved forest in the Rainy Area of West China].

    PubMed

    Zhou, Shi Xing; Zou, Cheng; Xiao, Yong Xiang; Xiang, Yuan Bin; Han, Bo Han; Tang, Jian Dong; Luo, Chao; Huang, Cong de

    2017-01-01

    To understand the effects of increasing nitrogen deposition on soil microbial biomass carbon (MBC) and nitrogen(MBN), an in situ experiment was conducted in a natural evergreen broad-leaved forest in Ya'an City, Sichuan Province. Four levels of nitrogen deposition were set: i.e., control (CK, 0 g N·m -2 ·a -1 ), low nitrogen (L, 5 g N·m -2 ·a -1 ), medium nitrogen (M, 15 g N·m -2 ·a -1 ), and high nitrogen (H, 30 g N·m -2 ·a -1 ). The results indicated that nitrogen deposition significantly decreased MBC and MBN in the 0-10 cm soil layer, and as N de-position increased, the inhibition effect was enhanced. L and M treatments had no significant effect on MBC and MBN in the 10-20 cm soil layer, while H treatment significantly reduced. The influence of N deposition on MBC and MBN was weakened with the increase of soil depth. MBC and MBN had obvious seasonal dynamic, which were highest in autumn and lowest in summer both in the 0-10 and 10-20 cm soil layers. The fluctuation ranges of soil microbial biomass C/N were respectively 10.58-11.19 and 9.62-12.20 in the 0-10 cm and 10-20 cm soil layers, which indicated that the fungi hold advantage in the soil microbial community in this natural evergreen broad-leaved forest.

  10. Do magnetic resonance imaging and computed tomography provide equivalent measures of rotator cuff muscle size in glenohumeral osteoarthritis?

    PubMed

    Chalmers, Peter N; Beck, Lindsay; Stertz, Irene; Aleem, Alexander; Keener, Jay D; Henninger, Heath B; Tashjian, Robert Z

    2018-05-10

    Rotator cuff muscle volume is associated with outcomes after cuff repair and total shoulder arthroplasty. Muscle area on select magnetic resonance imaging (MRI) slices has been shown to be a surrogate for muscle volume. The purpose of this study was to determine whether computed tomography (CT) provides an equivalent measurement of cuff muscle area to a previously validated MRI measurement. We included 30 patients before they were undergoing total shoulder arthroplasty with both preoperative CT and MRI scans performed within 30 days of one another at 1 institution using a consistent protocol. We reoriented CT sagittal and MRI sagittal T1 series orthogonal to the scapular plane. On both CT and MRI scans, we measured the area of the supraspinatus, infraspinatus-teres minor, and subscapularis on 2 standardized slices as previously described. We calculated intraclass correlation coefficients and mean differences. For the 30 subjects included, when MRI and CT were compared, the mean intraclass correlation coefficients were 0.989 (95% confidence interval [CI], 0.976-0.995) for the supraspinatus, 0.978 (95% CI, 0.954-0.989) for the infraspinatus-teres minor, and 0.977 (95% CI, 0.952-0.989) for the subscapularis. The mean differences were 0.2 cm 2 (95% CI, 0.0-0.4 cm 2 ) for the supraspinatus (P = .052), 0.8 cm 2 (95% CI, 0.1-1.4 cm 2 ) for the infraspinatus-teres minor (P = .029), and -0.3 cm 2 (95% CI, -1.2 to 0.5 cm 2 ) for the subscapularis (P = .407). CT provides nearly equivalent measures of cuff muscle area to an MRI technique with previously validated reliability and accuracy. While CT underestimates the infraspinatus area as compared with MRI, the difference is less than 1 cm 2 and thus likely clinically insignificant. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Wall shear stress in portal vein of cirrhotic patients with portal hypertension.

    PubMed

    Wei, Wei; Pu, Yan-Song; Wang, Xin-Kai; Jiang, An; Zhou, Rui; Li, Yu; Zhang, Qiu-Juan; Wei, Ya-Juan; Chen, Bin; Li, Zong-Fang

    2017-05-14

    To investigate wall shear stress (WSS) magnitude and distribution in cirrhotic patients with portal hypertension using computational fluid dynamics. Idealized portal vein (PV) system models were reconstructed with different angles of the PV-splenic vein (SV) and superior mesenteric vein (SMV)-SV. Patient-specific models were created according to enhanced computed tomography images. WSS was simulated by using a finite-element analyzer, regarding the blood as a Newtonian fluid and the vessel as a rigid wall. Analysis was carried out to compare the WSS in the portal hypertension group with that in healthy controls. For the idealized models, WSS in the portal hypertension group (0-10 dyn/cm 2 ) was significantly lower than that in the healthy controls (10-20 dyn/cm 2 ), and low WSS area (0-1 dyn/cm 2 ) only occurred in the left wall of the PV in the portal hypertension group. Different angles of PV-SV and SMV-SV had different effects on the magnitude and distribution of WSS, and low WSS area often occurred in smaller PV-SV angle and larger SMV-SV angle. In the patient-specific models, WSS in the cirrhotic patients with portal hypertension (10.13 ± 1.34 dyn/cm 2 ) was also significantly lower than that in the healthy controls ( P < 0.05). Low WSS area often occurred in the junction area of SV and SMV into the PV, in the area of the division of PV into left and right PV, and in the outer wall of the curving SV in the control group. In the cirrhotic patients with portal hypertension, the low WSS area extended to wider levels and the magnitude of WSS reached lower levels, thereby being more prone to disturbed flow occurrence. Cirrhotic patients with portal hypertension show dramatic hemodynamic changes with lower WSS and greater potential for disturbed flow, representing a possible causative factor of PV thrombosis.

  12. Wall shear stress in portal vein of cirrhotic patients with portal hypertension

    PubMed Central

    Wei, Wei; Pu, Yan-Song; Wang, Xin-Kai; Jiang, An; Zhou, Rui; Li, Yu; Zhang, Qiu-Juan; Wei, Ya-Juan; Chen, Bin; Li, Zong-Fang

    2017-01-01

    AIM To investigate wall shear stress (WSS) magnitude and distribution in cirrhotic patients with portal hypertension using computational fluid dynamics. METHODS Idealized portal vein (PV) system models were reconstructed with different angles of the PV-splenic vein (SV) and superior mesenteric vein (SMV)-SV. Patient-specific models were created according to enhanced computed tomography images. WSS was simulated by using a finite-element analyzer, regarding the blood as a Newtonian fluid and the vessel as a rigid wall. Analysis was carried out to compare the WSS in the portal hypertension group with that in healthy controls. RESULTS For the idealized models, WSS in the portal hypertension group (0-10 dyn/cm2) was significantly lower than that in the healthy controls (10-20 dyn/cm2), and low WSS area (0-1 dyn/cm2) only occurred in the left wall of the PV in the portal hypertension group. Different angles of PV-SV and SMV-SV had different effects on the magnitude and distribution of WSS, and low WSS area often occurred in smaller PV-SV angle and larger SMV-SV angle. In the patient-specific models, WSS in the cirrhotic patients with portal hypertension (10.13 ± 1.34 dyn/cm2) was also significantly lower than that in the healthy controls (P < 0.05). Low WSS area often occurred in the junction area of SV and SMV into the PV, in the area of the division of PV into left and right PV, and in the outer wall of the curving SV in the control group. In the cirrhotic patients with portal hypertension, the low WSS area extended to wider levels and the magnitude of WSS reached lower levels, thereby being more prone to disturbed flow occurrence. CONCLUSION Cirrhotic patients with portal hypertension show dramatic hemodynamic changes with lower WSS and greater potential for disturbed flow, representing a possible causative factor of PV thrombosis. PMID:28566887

  13. Separate first- and second-order processing is supported by spatial summation estimates at the fovea and eccentrically.

    PubMed

    Sukumar, Subash; Waugh, Sarah J

    2007-03-01

    We estimated spatial summation areas for the detection of luminance-modulated (LM) and contrast-modulated (CM) blobs at the fovea, 2.5, 5 and 10 deg eccentrically. Gaussian profiles were added or multiplied to binary white noise to create LM and CM blob stimuli and these were used to psychophysically estimate detection thresholds and spatial summation areas. The results reveal significantly larger summation areas for detecting CM than LM blobs across eccentricity. These differences are comparable to receptive field size estimates made in V1 and V2. They support the notion that separate spatial processing occurs for the detection of LM and CM stimuli.

  14. Composting of empty fruit bunches in the tower composter - effect of air intake holes

    NASA Astrophysics Data System (ADS)

    Irvan; Husaini, T.; Trisakti, B.; Batubara, F.; Daimon, H.

    2018-02-01

    The process of composting empty fruit bunches (EFB) by mixing with activated liquid organic fertilizer (ALOF) is an alternative utilization of solid waste generated from palm oil mill. This study aims to find composting techniques of EFB and to obtain degradation data of composting EFB by varying the air intake holes to produce good quality compost. Composting process was carried out by tearing the EFB into four shreds, then put into the tower composter while adding ALOF until it reached the optimum moisture content of 55 -65%. During the composting process, we maintained moisture content at optimum conditions by adding ALOF. Variations of air intake holes area to the outer surface area of the composter are 0/44.314; 72.39/44.314 and 144.78/44.314 (cm2/cm2). Composting is carried out for forty days, however, based on the result, compost began to mature on the 10th day. The results revealed that there was an influence of air intake holes to the composting process. The best degradation of EFB was obtained on the variation of air intake holes 72.39/44.314 (cm2/cm2), pH 8.1, moisture content 79.14%, water holding capacity 60%, electrical conductivity 4.725 dS/m and C/N ratio 20.97.

  15. The new Labcor-Santiago pericardial bioprosthesis.

    PubMed

    Garcia-Bengochea, J B; Casagrande, I; Gonzalez-Juanatey, J R; Puig, L; Rubio, J; Duran, D; Sierra, J

    1991-12-01

    The Labcor-Santiago pericardial valve has been designed to minimize mechanical stress and to avoid abrasion wear, at the same time preserving the concept of mounting the pericardium outside the posts for full orifice opening. The new design has preserved the traditional superior hemodynamic performance of pericardial valves, avoiding abrasion by careful padding of the stents and introducing a new concept of cusp attachment in order to increase mechanical durability. Since June 1990, 40 patients received 46 Labcor-Santiago valves: 29 in the aortic position and 17 in the mitral position. Mean age was 65.6 years. Eighty percent of the patients were women. New York Heart Association Functional Class III-IV was present in 76% of patients. Hospital mortality has been 12.5%, with 31% undergoing concomitant procedures. No anticoagulation was administered and there has been one thromboembolic event. Echo-Doppler assessment yielded the following in the aortic position: effective orifice area for 19-mm size = 1 cm2; for 21-mm size = 1.2 cm2. Mean systolic gradient for 19-mm size = 14.7 mmHg; for 21-mm size = 11.2 mmHg. In the mitral position: effective orifice area for 27-mm size = 2 cm2; for 29-mm size = 2.3 cm2. Mean diastolic gradients for 27-mm size = 4.6 mmHg; for 29-mm size = 3.3 mmHg. The low-profile flexible stent, the streamlined shape without outside prosthetic material, and the anatomical sewing rim allow a comfortable implantation of the Labcor-Santiago valve, particularly in the small aortic annulus. It is hoped that this new design will contribute to an increase in in vivo mechanical durability.

  16. Effects of contrast media on the hepato-pancreato-biliary system

    PubMed Central

    Topcu, Omer; Kurt, Atilla; Nadir, Isilay; Arici, Sema; Koyuncu, Ayhan; Aydin, Cengiz

    2009-01-01

    AIM: To determine the effects of high osmolarity contrast media (HOCM) and iso-osmolar contrast media (CM) application, with or without pressure, on hepato-pancreato-biliary (HPB) system. METHODS: Sixty rats were divided into six equal groups as follows: Group 1: (0.9% NaCl, control), Group 2: (diatrizoate meglumine Na, ionic HOCM, Urographin®), Group 3: (iodixanol, iso-osmolar non-ionic CM, Visipaque®); each of which was applied without pressure, whereas the animals of the remaining three groups (1p, 2p, 3p) were subjected to the same CM with pressure. We performed a duodenal puncture and introduced a catheter into the ampulla. After the catheterization, 0.2 mL CM or 0.9% NaCl was injected with or without pressure. Blood samples were taken for biochemical evaluations. The histopathological examinations of liver, common bile duct, and pancreas were performed. RESULTS: There were no significant differences between the six groups for blood amylase, alanine aminotransferases, aspartate aminotransferases, bilirubin levels (P > 0.05). Alkaline phosphatase and γ glutamyl transaminase levels were higher (P < 0.05) in the Urographin® groups (2, 2p) than the Visipaque® groups (3, 3p), or control groups (1, 1p). Hepatocyte necrosis, portal area inflammation, and Kupffer’s cell hyperplasia were higher (P < 0.05) in the study groups than the control group. However, there were no significant differences (P > 0.05) between HOCM (2, 2p) and iso-osmolar CM (3, 3p) groups. Bile duct proliferation and regeneration in the Urographin® groups (2, 2p) were significantly higher (P < 0.05) than the Visipaque® groups (3, 3p) or the control groups (1, 1p). Although CM caused minor damage to the pancreas, there were no statistically significant differences (P > 0.05) between the groups. Application of the CM with pressure did not cause additional damage to the HPB system. CONCLUSION: Iso-osmolar, non-ionic CM could be more reliable than the ionic HOCM, whereas the application of pressure during the CM application had no effect on the HPB system. PMID:19824112

  17. The Gas-Absorption/Chemical-Reaction Method for Measuring Air-Water Interfacial Area in Natural Porous Media

    NASA Astrophysics Data System (ADS)

    Lyu, Ying; Brusseau, Mark L.; El Ouni, Asma; Araujo, Juliana B.; Su, Xiaosi

    2017-11-01

    The gas-absorption/chemical-reaction (GACR) method used in chemical engineering to quantify gas-liquid interfacial area in reactor systems is adapted for the first time to measure the effective air-water interfacial area of natural porous media. Experiments were conducted with the GACR method, and two standard methods (X-ray microtomographic imaging and interfacial partitioning tracer tests) for comparison, using model glass beads and a natural sand. The results of a series of experiments conducted under identical conditions demonstrated that the GACR method exhibited excellent repeatability for measurement of interfacial area (Aia). Coefficients of variation for Aia were 3.5% for the glass beads and 11% for the sand. Extrapolated maximum interfacial areas (Am) obtained with the GACR method were statistically identical to independent measures of the specific solid surface areas of the media. For example, the Am for the glass beads is 29 (±1) cm-1, compared to 32 (±3), 30 (±2), and 31 (±2) cm-1 determined from geometric calculation, N2/BET measurement, and microtomographic measurement, respectively. This indicates that the method produced accurate measures of interfacial area. Interfacial areas determined with the GACR method were similar to those obtained with the standard methods. For example, Aias of 47 and 44 cm-1 were measured with the GACR and XMT methods, respectively, for the sand at a water saturation of 0.57. The results of the study indicate that the GACR method is a viable alternative for measuring air-water interfacial areas. The method is relatively quick, inexpensive, and requires no specialized instrumentation compared to the standard methods.

  18. Coaxial fiber supercapacitor using all-carbon material electrodes.

    PubMed

    Le, Viet Thong; Kim, Heetae; Ghosh, Arunabha; Kim, Jaesu; Chang, Jian; Vu, Quoc An; Pham, Duy Tho; Lee, Ju-Hyuck; Kim, Sang-Woo; Lee, Young Hee

    2013-07-23

    We report a coaxial fiber supercapacitor, which consists of carbon microfiber bundles coated with multiwalled carbon nanotubes as a core electrode and carbon nanofiber paper as an outer electrode. The ratio of electrode volumes was determined by a half-cell test of each electrode. The capacitance reached 6.3 mF cm(-1) (86.8 mF cm(-2)) at a core electrode diameter of 230 μm and the measured energy density was 0.7 μWh cm(-1) (9.8 μWh cm(-2)) at a power density of 13.7 μW cm(-1) (189.4 μW cm(-2)), which were much higher than the previous reports. The change in the cyclic voltammetry characteristics was negligible at 180° bending, with excellent cycling performance. The high capacitance, high energy density, and power density of the coaxial fiber supercapacitor are attributed to not only high effective surface area due to its coaxial structure and bundle of the core electrode, but also all-carbon materials electrodes which have high conductivity. Our coaxial fiber supercapacitor can promote the development of textile electronics in near future.

  19. 50 CFR Appendix D to Part 622 - Specifications for Certified BRDs

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (7.6-cm) piece of 1/2-inch (1.3-cm) aluminum pipe and pressed with a 3/8-inch (0.95-cm) die to form a... must be constructed of either number 60 twine 80 inches (203.2 cm) in length or 3/8-inch (0.95-cm... excluder device (TED) grid; and, (4) the area of the escape opening must total at least 864 in2 (5,574.2...

  20. Comparison of the effects of topical application of UMF20 and UMF5 manuka honey with a generic multifloral honey on wound healing variables in an uncontaminated surgical equine distal limb wound model.

    PubMed

    Tsang, A S; Dart, A J; Sole-Guitart, A; Dart, C M; Perkins, N R; Jeffcott, L B

    2017-09-01

    To compare the effect of application of manuka honey with unique manuka factor (UMF) 5 or 20 with a generic multifloral honey on equine wound healing variables. Two full-thickness skin wounds (2.5 × 2.5 cm) were created on the metatarsus of both hindlimbs of eight Standardbred horses. The wounds on each horse were assigned to 1 of 4 treatments: UMF20 (UMF20) and UMF5 (UMF5) manuka honey; generic multifloral honey (GH); and a saline control. Bandages were changed daily for 12 days, after which treatment was stopped and the bandages were removed. Wound area was measured on day 1, then weekly until day 42. Overall wound healing rate (cm 2 /day) and time to complete healing were recorded. There was no difference in wound area for any of the treatments on any measurement day except for day 21, where the mean wound area for wounds treated with UMF20 was smaller than the mean wound area for the UMF5-treated wounds (P = 0.031). There was no difference in mean (± SE) overall healing rate (cm 2 /day) among the treatment groups. There were differences in mean (± SE) days to complete healing. Wounds treated with UMF20 healed faster than wounds treated with GH (P = 0.02) and control wounds (P = 0.01). Treatment of wounds with UMF20 reduced overall wound healing time compared with wounds treated with GH and control wounds. However, using this model the difference in the overall time to complete healing was small. © 2017 Australian Veterinary Association.

  1. Comparison of valvular resistance, stroke work loss, and Gorlin valve area for quantification of aortic stenosis. An in vitro study in a pulsatile aortic flow model.

    PubMed

    Voelker, W; Reul, H; Nienhaus, G; Stelzer, T; Schmitz, B; Steegers, A; Karsch, K R

    1995-02-15

    Valvular resistance and stroke work loss have been proposed as alternative measures of stenotic valvular lesions that may be less flow dependent and, thus, superior over valve area calculations for the quantification of aortic stenosis. The present in vitro study was designed to compare the impacts of valvular resistance, stroke work loss, and Gorlin valve area as hemodynamic indexes of aortic stenosis. In a pulsatile aortic flow model, rigid stenotic orifices in varying sizes (0.5, 1.0, 1.5 and 2.0 cm2) and geometry were studied under different hemodynamic conditions. Ventricular and aortic pressures were measured to determine the mean systolic ventricular pressure (LVSPm) and the transstenotic pressure gradient (delta Pm). Transvalvular flow (Fm) was assessed with an electromagnetic flowmeter. Valvular resistance [VR = 1333.(delta Pm/Fm)] and stroke work loss [SWL = 100.(delta Pm/LVSPm)] were calculated and compared with aortic valve area [AVA = Fm/(50 square root of delta Pm)]. The measurements were performed for a large range of transvalvular flows. At low-flow states, flow augmentation (100-->200 mL/s) increased calculated valvular resistance between 21% (2.0 cm2 orifice) and 66% (0.5-cm2 orifice). Stroke work loss demonstrated an increase from 43% (2.0 cm2) to 100% (1.0 cm2). In contrast, Gorlin valve area revealed only a moderate change from 29% (2.0 cm2) to 5% (0.5 cm2). At physiological flow rates, increase in transvalvular flow (200-->300 mL/s) did not alter calculated Gorlin valve area, whereas valvular resistance and stroke work loss demonstrated a continuing increase. Our experimental results were adopted to interpret the results of three clinical studies in aortic stenosis. The flow-dependent increase of Gorlin valve area, which was found in the cited clinical studies, can be elucidated as true further opening of the stenotic valve but not as a calculation error due to the Gorlin formula. Within the physiological range of flow, calculated aortic valve area was less dependent on hemodynamic conditions than were valvular resistance and stroke work loss, which varied as a function of flow. Thus, for the assessment of the severity of aortic stenosis, the Gorlin valve area is superior over valvular resistance and stroke work loss, which must be indexed for flow to adequately quantify the hemodynamic severity of the obstruction.

  2. Intussusception reduction: Effect of air vs. liquid enema on radiation dose.

    PubMed

    Kaplan, Summer L; Magill, Dennise; Felice, Marc A; Edgar, J Christopher; Anupindi, Sudha A; Zhu, Xiaowei

    2017-10-01

    Both air and radiopaque liquid contrast are used to reduce ileocolic intussusception under fluoroscopy. Some suggest air lowers radiation dose due to shorter procedure times. However, air enema likely lowers radiation dose regardless of fluoroscopy time due to less density over the automatic exposure control cells. We test the hypothesis that air enema reduction of ileocolic intussusception results in lower radiation dose than liquid contrast enema independent of fluoroscopy time. We describe a role for automatic exposure control in this dose difference. We retrospectively evaluated air and liquid intussusception reductions performed on a single digital fluoroscopic unit during a 26-month period. We compared patient age, weight, gender, exam time of day and year, performing radiologist(s), radiographic image acquisitions, grid and magnification use, fluoroscopy time and dose area product. We compared categorical and continuous variables statistically using chi-square and Mann-Whitney U tests, respectively. The mean dose area product was 2.7-fold lower for air enema, 1.3 ± 0.9 dGy·cm 2 , than for liquid, 3.5 ± 2.5 dGy·cm 2 (P<0.005). The mean fluoroscopy time was similar between techniques. The mean dose area product/min was 2.3-fold lower for air, 0.6 ± 0.2 dGy·cm 2 /min, than for liquid, 1.4 ± 0.5 dGy·cm 2 /min (P<0.001). No group differences were identified in other measured dose parameters. Fluoroscopic intussusception reduction using air enema uses less than half the radiation dose of liquid contrast enema. Dose savings are independent of fluoroscopy time and are likely due to automatic exposure control interaction.

  3. The potential for translocation of marine species via small-scale disruptions to antifouling surfaces.

    PubMed

    Piola, Richard F; Johnston, Emma L

    2008-01-01

    Vessel hull fouling is a major vector for the translocation of nonindigenous species (NIS). Antifouling (AF) paints are the primary method for preventing the establishment and translocation of fouling species. However, factors such as paint age, condition and method of application can all reduce the effectiveness of these coatings. Areas of hull that escape AF treatment (through limited application or damage) constitute key areas that may be expected to receive high levels of fouling. The investigation focused on whether small-scale (mm(2) to cm(2)) areas of unprotected surface or experimental 'scrapes' provided sufficient area for the formation of fouling assemblages within otherwise undamaged AF surfaces. Recruitment of fouling taxa such as algae, spirorbids and hydroids was recorded on scrapes as narrow as 0.5 cm wide. The abundance and species richness of fouling assemblages developing on scrapes > or =1 cm often equalled or surpassed levels observed in reference assemblages totally unprotected by AF coatings. Experiments were conducted at three sites within the highly protected and isolated marine park surrounding Lady Elliott Island at the southernmost tip of the Great Barrier Reef, Australia. Several NIS were recorded on scrapes of AF coated surfaces at this location, with 1-cm scrapes showing the greatest species richness and abundance of NIS relative to all other treatments (including controls) at two of the three sites investigated. Slight disruptions to newly antifouled surfaces may be all that is necessary for the establishment of fouling organisms and the translocation of a wide range of invasive taxa to otherwise highly protected marine areas.

  4. EFFECTS OF LASER RADIATION ON MATTER: Efficient surface-erosion plasma formation in air due to the action of pulse-periodic laser radiation

    NASA Astrophysics Data System (ADS)

    Min'ko, L. Ya; Chumakou, A. N.; Bosak, N. A.

    1990-11-01

    A study was made of the interaction of a series of periodic laser (λ = 1.06 μm) pulses with a number of materials (aluminum, copper, graphite, ebonite) in air at laser radiation power densities q = 107-109 W/cm2 and repetition frequencies f<=50 kHz. The radiation was concentrated in spots of ~ 10 - 2 cm2 area. Efficient formation of plasma as a result of laser erosion (q > 2 × 108 W/cm2, f>=5 kHz) was observed. A screening layer of an air plasma created by the first pulse of the series was expelled from the interaction zone and this was followed by erosion plasma formation under conditions of slight screening of the target during the action of the subsequent laser pulses.

  5. Local Helicity Injection Systems for Non-solenoidal Startup in the PEGASUS Toroidal Experiment

    NASA Astrophysics Data System (ADS)

    Perry, J. M.; Barr, J. L.; Bongard, M. W.; Fonck, R. J.; Hinson, E. T.; Lewicki, B. T.; Redd, A. J.

    2013-10-01

    Local helicity injection is being developed in the PEGASUS Toroidal Experiment for non-solenoidal startup in spherical tokamaks. The effective loop voltage due to helicity injection scales with the area of the injectors, requiring the development of electron current injectors with areas much larger than the 2 cm2 plasma arc injectors used to date. Solid and gas-effused metallic electrodes were found to be unusable due to reduced injector area utilization from localized cathode spots and narrow operational regimes. An integrated array of 8 compact plasma arc sources is thus being developed for high current startup. It employs two monolithic power systems, for the plasma arc sources and the bias current extraction system. The array effectively eliminates impurity fueling from plasma-material interaction by incorporating a local scraper-limiter and conical-frustum bias electrodes to mitigate the effects of cathode spots. An energy balance model of helicity injection indicates that the resulting 20 cm2 of total injection area should provide sufficient current drive to reach 0.3 MA. At that level, helicity injection drive exceeds that from poloidal induction, which is the relevant operational regime for large-scale spherical tokamaks. Future placement of the injector array near an expanded boundary divertor region will test simultaneous optimization of helicity drive and the Taylor relaxation current limit. Work supported by US DOE Grant DE-FG02-96ER54375.

  6. Precise computation of the direct and indirect topographic effects of Helmert's 2nd method of condensation using SRTM30 digital elevation model

    NASA Astrophysics Data System (ADS)

    Wang, Y.

    2011-01-01

    The direct topographic effect (DTE) and indirect topographic effect (ITE) of Helmert's 2nd method of condensation are computed using the digital elevation model (DEM) SRTM30 in 30 arc-seconds globally. The computations assume a constant density of the topographic masses. Closed formulas are used in the inner zone of half degree, and Nagy's formulas are used in the innermost column to treat the singularity of integrals. To speed up the computations, 1-dimensional fast Fourier transform (1D FFT) is applied in outer zone computations. The computation accuracy is limited to 0.1 mGal and 0.1cm for the direct and indirect effect, respectively. The mean value and standard deviation of the DTE are -0.8 and ±7.6 mGal over land areas. The extreme value -274.3 mGal is located at latitude -13.579° and longitude 289.496°, at the height of 1426 meter in the Andes Mountains. The ITE is negative everywhere and has its minimum of -235.9 cm at the peak of Himalayas (8685 meter). The standard deviation and mean value over land areas are ±15.6 cm and -6.4 cm, respectively. Because the Stokes kernel does not contain the zero and first degree spherical harmonics, the mean value of the ITE can't be compensated through the remove-restore procedure under the Stokes-Helmert scheme, and careful treatment of the mean value in the ITE is required.

  7. Large area, low cost space solar cells with optional wraparound contacts

    NASA Technical Reports Server (NTRS)

    Michaels, D.; Mendoza, N.; Williams, R.

    1981-01-01

    Design parameters for two large area, low cost solar cells are presented, and electron irradiation testing, thermal alpha testing, and cell processing are discussed. The devices are a 2 ohm-cm base resistivity silicon cell with an evaporated aluminum reflector produced in a dielectric wraparound cell, and a 10 ohm-cm silicon cell with the BSF/BSR combination and a conventional contact system. Both cells are 5.9 x 5.9 cm and require 200 micron thick silicon material due to mission weight constraints. Normalized values for open circuit voltage, short circuit current, and maximum power calculations derived from electron radiation testing are given. In addition, thermal alpha testing values of absorptivity and emittance are included. A pilot cell processing run produced cells averaging 14.4% efficiencies at AMO 28 C. Manufacturing for such cells will be on a mechanized process line, and the area of coverslide application technology must be considered in order to achieve cost effective production.

  8. Facile Co-Electrodeposition Method for High-Performance Supercapacitor Based on Reduced Graphene Oxide/Polypyrrole Composite Film.

    PubMed

    Chen, Junchen; Wang, Yaming; Cao, Jianyun; Liu, Yan; Zhou, Yu; Ouyang, Jia-Hu; Jia, Dechang

    2017-06-14

    A facile co-electrodeposition method has been developed to fabricate reduced graphene oxide/polypyrrole (rGO/PPy) composite films, with sodium dodecyl benzene sulfonate as both a surfactant and supporting electrolyte in the precursor solution. The introduction of rGO into the PPy films forms porous structure and enhances the conductivity across the film, leading to superior electrochemical performance. By controlling the deposition time and rGO concentration, the highest area capacitance can reach 411 mF/cm 2 (0.2 mA/cm 2 ) for rGO/PPy films, whereas optimized specific capacitance is as high as 361 F/g (0.2 mA/cm 2 ). All of the composite films exhibit excellent rate capability (at least 175 F/g at the current density of 12 mA/cm 2 ) compared with pure PPy film (only 12 F/g at the current density of 12 mA/cm 2 ). The rGO/PPy composite exhibits excellent cycling stability that maintains 104% of its initial capacitance after cycling for 2000 cycles and 80% for 5000 cycles. The two-electrode solid-state supercapacitor (SC) based on rGO/PPy composite electrodes demonstrates good rate performance, excellent cycling stability, as well as a high area capacitance of 222 mF/cm 2 . The solid-state planar SC based on the rGO/PPy composite exhibits an area capacitance of 9.4 mF/cm 2 , demonstrating great potential for fabrication of microsupercapacitors.

  9. Combining axial and radial nanowire heterostructures: radial Esaki diodes and tunnel field-effect transistors.

    PubMed

    Dey, Anil W; Svensson, Johannes; Ek, Martin; Lind, Erik; Thelander, Claes; Wernersson, Lars-Erik

    2013-01-01

    The ever-growing demand on high-performance electronics has generated transistors with very impressive figures of merit (Radosavljevic et al., IEEE Int. Devices Meeting 2009, 1-4 and Cho et al., IEEE Int. Devices Meeting 2011, 15.1.1-15.1.4). The continued scaling of the supply voltage of field-effect transistors, such as tunnel field-effect transistors (TFETs), requires the implementation of advanced transistor architectures including FinFETs and nanowire devices. Moreover, integration of novel materials with high electron mobilities, such as III-V semiconductors and graphene, are also being considered to further enhance the device properties (del Alamo, Nature 2011, 479, 317-323, and Liao et al., Nature 2010, 467, 305-308). In nanowire devices, boosting the drive current at a fixed supply voltage or maintaining a constant drive current at a reduced supply voltage may be achieved by increasing the cross-sectional area of a device, however at the cost of deteriorated electrostatics. A gate-all-around nanowire device architecture is the most favorable electrostatic configuration to suppress short channel effects; however, the arrangement of arrays of parallel vertical nanowires to address the drive current predicament will require additional chip area. The use of a core-shell nanowire with a radial heterojunction in a transistor architecture provides an attractive means to address the drive current issue without compromising neither chip area nor device electrostatics. In addition to design advantages of a radial transistor architecture, we in this work illustrate the benefit in terms of drive current per unit chip area and compare the experimental data for axial GaSb/InAs Esaki diodes and TFETs to their radial counterparts and normalize the electrical data to the largest cross-sectional area of the nanowire, i.e. the occupied chip area, assuming a vertical device geometry. Our data on lateral devices show that radial Esaki diodes deliver almost 7 times higher peak current, Jpeak = 2310 kA/cm(2), than the maximum peak current of axial GaSb/InAs(Sb) Esaki diodes per unit chip area. The radial TFETs also deliver high peak current densities Jpeak = 1210 kA/cm(2), while their axial counterparts at most carry Jpeak = 77 kA/cm(2), normalized to the largest cross-sectional area of the nanowire.

  10. Measurements of tropospheric NO2 in Romania using a zenith-sky mobile DOAS system and comparisons with satellite observations.

    PubMed

    Constantin, Daniel-Eduard; Merlaud, Alexis; Van Roozendael, Michel; Voiculescu, Mirela; Fayt, Caroline; Hendrick, François; Pinardi, Gaia; Georgescu, Lucian

    2013-03-20

    In this paper we present a new method for retrieving tropospheric NO2 Vertical Column Density (VCD) from zenith-sky Differential Optical Absorption Spectroscopy (DOAS) measurements using mobile observations. This method was used during three days in the summer of 2011 in Romania, being to our knowledge the first mobile DOAS measurements peformed in this country. The measurements were carried out over large and different areas using a mobile DOAS system installed in a car. We present here a step-by-step retrieval of tropospheric VCD using complementary observations from ground and space which take into account the stratospheric contribution, which is a step forward compared to other similar studies. The detailed error budget indicates that the typical uncertainty on the retrieved NO2tropospheric VCD is less than 25%. The resulting ground-based data set is compared to satellite measurements from the Ozone Monitoring Instrument (OMI) and the Global Ozone Monitoring Experiment-2 (GOME-2). For instance, on 18 July 2011, in an industrial area located at 47.03°N, 22.45°E, GOME-2 observes a tropospheric VCD value of (3.4 ± 1.9) × 1015 molec./cm2, while average mobile measurements in the same area give a value of (3.4 ± 0.7) × 10(15) molec./cm2. On 22 August 2011, around Ploiesti city (44.99°N, 26.1°E), the tropospheric VCD observed by satellites is (3.3 ± 1.9) × 10(15) molec./cm2 (GOME-2) and (3.2 ± 3.2) × 10(15) molec./cm2 (OMI), while average mobile measurements give (3.8 ± 0.8) × 10(15) molec./cm2. Average ground measurements over "clean areas", on 18 July 2011, give (2.5 ± 0.6) × 10(15) molec./cm2 while the satellite observes a value of (1.8 ± 1.3) × 10(15) molec./cm2.

  11. Use of conventional tomography to evaluate changes in the nasal cavity with rapid palatal expansion.

    PubMed

    Palaisa, Jacqueline; Ngan, Peter; Martin, Chris; Razmus, Thomas

    2007-10-01

    The relationship between nasal airway resistance and the use of rapid palatal expansion appliances remains controversial. The purpose of this study was to use conventional tomography to determine the anatomical changes in the nasal cavity after maxillary expansion. Nineteen patients (aged 8-15 years) were included in the study. Tomograms were taken before expansion (T1), immediately after expansion (T2), and 3 months after expansion (T3). Areas for the left and right anterior, middle, and posterior nasal cavity and total volume were calculated by using the computer software, AutoCAD LT 2005. Data were analyzed with paired t tests. Significant increases in area were found in the anterior nasal cavity from T1 to T2 (0.85 +/- 1.19 cm2, 11.7% increase), T2 to T3 (1.18 +/- 1.2 cm2, 22.2% increase), and T1 to T3 (2.6 +/- 1.7 cm2, 35.7% increase) (P <.05). Similar increases were found in the middle and posterior nasal cavity. Significant increases in volume were found from T1 to T2 (2.1 +/- 2.7 cm3, 10.7% increase), T2 to T3 (4.9 +/- 2.3 cm3, 22.6% increase), and T1 to T3 (6.99 +/- 2.45 cm3, 27.8% increase). No significant differences were found in the area or the volume of the left and right sides of the nasal cavity. Individual variations in response to maxillary expansion were large for most of the parameters tested. These data suggest that rapid palatal expansion is usually accompanied by increases in area and volume of the nasal cavity, and these changes remain stable 3 months after maxillary expansion.

  12. Comparable Effects of High-Intensity Interval Training and Prolonged Continuous Exercise Training on Abdominal Visceral Fat Reduction in Obese Young Women.

    PubMed

    Zhang, Haifeng; Tong, Tom K; Qiu, Weifeng; Zhang, Xu; Zhou, Shi; Liu, Yang; He, Yuxiu

    2017-01-01

    This study compared the effect of prolonged moderate-intensity continuous training (MICT) on reducing abdominal visceral fat in obese young women with that of work-equivalent (300 kJ/training session) high-intensity interval training (HIIT). Forty-three participants received either HIIT ( n = 15), MICT ( n = 15), or no training (CON, n = 13) for 12 weeks. The abdominal visceral fat area (AVFA) and abdominal subcutaneous fat area (ASFA) of the participants were measured through computed tomography scans preintervention and postintervention. Total fat mass and the fat mass of the android, gynoid, and trunk regions were assessed through dual-energy X-ray absorptiometry. Following HIIT and MICT, comparable reductions in AVFA (-9.1, -9.2 cm 2 ), ASFA (-35, -28.3 cm 2 ), and combined AVFA and ASFA (-44.7, -37.5 cm 2 , p > 0.05) were observed. Similarly, reductions in fat percentage (-2.5%, -2.4%), total fat mass (-2.8, -2.8 kg), and fat mass of the android (-0.3, -0.3 kg), gynoid (-0.5, -0.7 kg), and trunk (-1.6, -1.2 kg, p > 0.05) regions did not differ between HIIT and MICT. No variable changed in CON. In conclusion, MICT consisting of prolonged sessions has no quantitative advantage, compared with that resulting from HIIT, in abdominal visceral fat reduction. HIIT appears to be the predominant strategy for controlling obesity because of its time efficiency.

  13. Evaluation of healing of infected cutaneous wounds treated with different energy densities

    NASA Astrophysics Data System (ADS)

    Santos, Nicole R. S.; Cangussú, Maria C. T.; N. dos Santos, Jean; Pinheiro, Antonio L. B.

    2011-03-01

    We aimed assess the effects of different energy densities of the association of red/IR laser light on the healing of cutaneous wounds infected Staphylococcus aureus. Background: Wound infection is the most common complication on healing wounds and cause both vascular and cellular responses on the tissue. Several therapeutics is used for improving wound healing including the use of different light sources, such as the Laser. Some energy densities present positive photobiological effects on the healing process. Material and Methods: 24 young adult male Wistar rats, under general anesthesia, had their dorsum shaven, cleaned and a 1 x 1cm cutaneous wound created with a scalpel and left without no suturing or dressings. The wounds were infected with Staphylococcus aureus and were randomly divided in 8 subgroups of 3 animals in each: Control, Group 10J/cm2, Group 20J/cm2, and Group 30J/cm2, 7 and 14 days each group. Laser phototherapy was carried out with a diode (λ680nm/790nm, P= 30mW/40mW, CW, Laser, Ø = 3mm, PD=424mW/cm2 and 566mW/cm2, t=11.8/ 8.8 sec, E=0.35J) and started immediately after surgery and repeated at every other day during 7 days. Laser light was applied on 4 points around wounded area. The animals were killed at either 8th or 15th day after contamination. Specimens were taken, routinely cut and processed to wax, stained and underwent histological analysis. The results were statistically analyzed. Results: Both 20 and 30J/cm2 caused intense collagen deposition at the end of the experimental time. But, when 20 J/cm2 was used the fibers were also well organized. Conclusion: Our results indicate that irradiated subjects showed improved wound healing being the 20 J/cm2 the energy the caused better histological response.

  14. Real-time {sup 90}Sr Counter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaneko, Naomi; Kawai, Hideyuki; Kodama, Satoshi

    2015-07-01

    Radioisotopes have been emitted around Japan due to a nuclear accident at the Fukushima Daiichi nuclear power station in March 2011. A problem is the contaminated water including the atomic nucleus which relatively has a long half- life time and soluble such as {sup 90}Sr, {sup 137}Cs. Internal exposures by {sup 90}Sr are more dangerous than {sup 137}Cs's because Sr has effective half-life time of 18 years and property of accumulation in a born. We have developed real-time {sup 90}Sr counter which is sensitive beta-ray of maximum kinematic energy of 2.28 MeV from {sup 90}Sr and insensitive of beta-ray ofmore » maximum kinematic energy of 1.17 MeV and gamma-ray from {sup 90}Sr by Cherenkov detection. This counter composes of Cerenkov counter, trigger scintillation counter and veto counter. Silica aerogel for Cherenkov counter can obtain refractive index between 1.017 and 1.049 easily. And wavelength shifting fiber (WLSF) is used as a light guide for extending effective area and producing lower cost. A mechanism of the identification of {sup 90}Sr is explained in following. In case of {sup 90}Sr, when the trigger counter reacts on the beta-ray from {sup 90}Sr, aerogel emits the Cherenkov light and WLSF reacts and read the Cherenkov light. On the other hand, in case of {sup 137}Cs, the trigger counter reacts on the beta-ray, aerogel stops the beta- ray and Cherenkov light is not emitted. Therefore, aerogel has a function as a radiator and shielding material. the gamma-ray is not reacted on the lower density detector. Cosmic rays would be also reacted by the veto counter. A prototype counter whose the effective area is 30 cm x 10 cm was obtained (2.0±1.2){sup 3} of mis-identification as {sup 137}Cs/{sup 90}Sr. Detection limit in the surface contamination inspection depends on measurement time and effective area mainly. The sensitivity of wide range, 10{sup -2} - 10{sup 4} Bq/cm{sup 2}, is obtained by adjustment of detection level in circuit of this counter. A lower radioactive sample (< 10{sup -2} Bq/cm{sup 2}) allows be detected significantly by heating treatment to evaporate water shielding the beta-rays. (authors)« less

  15. Integration of 3D imaging data in the assessment of aortic stenosis: impact on classification of disease severity.

    PubMed

    O'Brien, Bridget; Schoenhagen, Paul; Kapadia, Samir R; Svensson, Lars G; Rodriguez, Leonardo; Griffin, Brian P; Tuzcu, E Murat; Desai, Milind Y

    2011-09-01

    In patients with aortic stenosis (AS), precise assessment of severity is critical for treatment decisions. Estimation of aortic valve area (AVA) with transthoracic echocardiographic (TTE)-continuity equation (CE) assumes a circular left ventricular outflow tract (LVOT). We evaluated incremental utility of 3D multidetector computed tomography (MDCT) over TTE assessment of AS severity. We included 51 patients (age, 81±8 years; 61% men; mean gradient, 42 ± 12 mm Hg) with calcific AS who underwent evaluation for treatment options. TTE parameters included systolic LVOT diameter (D) and continuous and pulsed wave (CW and PW) velocity-time integrals (VTI) through the LVOT and mean transaortic gradient. MDCT parameters included systolic LVOT area, ratio of maximal to minimal LVOT diameter (eccentricity index), and aortic planimetry (AVA(p)). TTE-CE AVA [(D(2)×0.786×VTIpw)/VTIcw] and dimensionless index (DI) [VTIpw/VTIcw] were calculated. Corrected AVA was calculated by substituting MDCT LVOT area into CE. The majority (96%) of patients had eccentric LVOT. LVOT area, measured on MDCT, was higher than on TTE (3.84 ± 0.8 cm(2) versus 3.03 ± 0.5 cm(2), P<0.01). TTE-AVA was smaller than AVA(p) and corrected AVA (0.67 ± 0.1cm(2), 0.82 ± 0.3 cm(2), and 0.86 ± 0.3 cm(2), P<0.01). Using TTE measurements alone, 73% of patients had congruence for severe AS (DI ≤0.25 and CE AVA <0.8 cm(2)), which increased to 92% using corrected CE. In patients with suspected severe AS, incorporation of MDCT-LVOT area into CE improves congruence for AS severity.

  16. Interaction of high voltage surfaces with the space plasma. [solar arrays

    NASA Technical Reports Server (NTRS)

    Kaufman, H. R.; Robinson, R. S.

    1979-01-01

    Tests were conducted using plasma densities of approximately 10 to the 5th power - 10 to the 6th power/cu cm. Insulating materials tested were polyimide (Dapton), mica and glass. Surface-area effects were found to be substantially reduced from those previously reported at lower plasma densities. The difference in typical plasma density was felt to be the major cause of this change, although a saturation effect may also be involved. At the 10 to the 5th power/cu cm plasma density range, surface effects on collection current appear limited to roughly 1 cm from the hole. A factor of several reduction of collected current was obtained with both surface scribing and a 2 x 2 cm conducting mesh. It appears possible that the effects of surface treatment might be more significant at lower plasma densities. Effects of repeated tests were also noted, with current collection decreasing with successive tests. Depending on the materials involved, the effect appeared due to either the smoothing of the inside of the insulator hole or the sputtering of insulator on the exposed conductor. A general conclusion was made from a variety of observations, that the generation of vapor is a major factor in the enhancement of collected current.

  17. Aggregate Stability and Erodibility of Purple Soil on Sloping Farmland as affected by different Soil Thickness

    NASA Astrophysics Data System (ADS)

    Huang, Xinjun; Zhang, Qingwen; Chen, Shanghong; Dong, Yuequn; Xiao, Meijia; Hamed, Lamy Mamdoh Mohamed

    2017-04-01

    Soil thickness is basic limiting condition for purple soil, not only due to its effect on crop production, but also its effect on soil structure. Steady-state of soil thickness will be achieved over time, as result the soil aggregate which the key factor of soil erodibility can be enhanced as well. However, the effect of soil thickness on aggregates stability and the characteristics of soil erodibility in sloping land have not yet fully understood.A field survey was conducted in hilly area of Sichuan region located in southeast China to study the relationship between soil aggregate stability and soil erodibility on sloping farmland under different four thickness (100cm, 80cm, 60cm, 30cm) of purple soil. Based on two different sieving methods (Dry and Wet sieving), we analyzed soil aggregate stability and its effect on soil erodibility within depth of 0-30cm soil layers. The results indicated that: Water stable aggregate on sloping farmland was ranged between 37.9% to 58.6%, where it increased with increasing the soil thickness. Moreover, fractal dimension calculated from dry-sieving and wet-sieving was 2.06-2.49 and 2.70-2.85 respectively, where it decreased with decreasing the soil thickness. The overall soil erodibility was 0.05-1.00 and a negative significant correlation was found between soil aggregate stability and erodibility(P<0.01). Moreover, farmland with thick soil profile tended to be high in soil erodibility within the top soil layer (0-30cm). The results reveal that soil thickness can affect soil aggregate stability as well as erodibility. As soil thickness increased, the top soil became more stable and less erodible. Keywords:purple soil; soil thickness; soil aggregate;soil erodibility

  18. Influence of specific surface area on coal dust explosibility using the 20-L chamber.

    PubMed

    Zlochower, Isaac A; Sapko, Michael J; Perera, Inoka E; Brown, Connor B; Harris, Marcia L; Rayyan, Naseem S

    2018-07-01

    The relationship between the explosion inerting effectiveness of rock dusts on coal dusts, as a function of the specific surface area (cm 2 /g) of each component is examined through the use of 20-L explosion chamber testing. More specifically, a linear relationship is demonstrated for the rock dust to coal dust (or incombustible to combustible) content of such inerted mixtures with the specific surface area of the coal and the inverse of that area of the rock dust. Hence, the inerting effectiveness, defined as above, is more generally linearly dependent on the ratio of the two surface areas. The focus on specific surface areas, particularly of the rock dust, provide supporting data for minimum surface area requirements in addition to the 70% less than 200 mesh requirement specified in 30 CFR 75.2.

  19. Effect of environment on fatigue failure of controlled memory wire nickel-titanium rotary instruments.

    PubMed

    Shen, Ya; Qian, Wei; Abtin, Houman; Gao, Yuan; Haapasalo, Markus

    2012-03-01

    This study examined the fatigue behavior of 2 types of nickel-titanium (NiTi) instruments made from a novel controlled memory NiTi wire (CM wire) under various environment conditions. Three conventional superelastic NiTi instruments of ProFile (Dentsply Maillefer, Ballaigues, Switzerland), Typhoon (Clinician's Choice Dental Products, New Milford, CT), and DS-SS0250425NEYY (Clinician's Choice Dental Products) and 2 new CM wire instruments of Typhoon CM and DS-SS0250425NEYY CM were subjected to rotational bending at the curvature of 35° in air, deionized water, 17% EDTA, or deionized water after immersion in 6% sodium hypochlorite for 25 minutes, and the number of revolutions of fracture (N(f)) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. The crack-initiation sites and the percentage of dimple area to the whole fracture cross-section were noted. Two new CM Wire instruments yielded an improvement of >4 to 9 times in N(f) than conventional NiTi files with the same design under various environments (P < .05). The fatigue life of 3 conventional superelastic NiTi instruments was similar under various environments, whereas the N(f) of 2 new CM Wire instruments was significantly longer in liquid media than in air (P < .05). The vast majority of CM instruments showed multiple crack origins, whereas most instruments made from conventional NiTi wire had one crack origin. The values of the area fraction occupied by the dimple region were significantly smaller on CM NiTi instruments than in conventional NiTi instruments under various environments (P < .05). Within the limitations of this study, the type of NiTi metal alloy (CM files vs conventional superelastic NiTi files) influences the cyclic fatigue resistance under various environments. The fatigue life of CM instruments is longer in liquid media than in air. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Quick Fabrication of Large-area Organic Semiconductor Single Crystal Arrays with a Rapid Annealing Self-Solution-Shearing Method

    PubMed Central

    Li, Yunze; Ji, Deyang; Liu, Jie; Yao, Yifan; Fu, Xiaolong; Zhu, Weigang; Xu, Chunhui; Dong, Huanli; Li, Jingze; Hu, Wenping

    2015-01-01

    In this paper, we developed a new method to produce large-area single crystal arrays by using the organic semiconductor 9, 10-bis (phenylethynyl) anthracene (BPEA). This method involves an easy operation, is efficient, meets the demands of being low-cost and is independent of the substrate for large-area arrays fabrication. Based on these single crystal arrays, the organic field effect transistors exhibit the superior performance with the average mobility extracting from the saturation region of 0.2 cm2 V−1s−1 (the highest 0.47 cm2 V−1s−1) and on/off ratio exceeding 105. In addition, our single crystal arrays also show a very high photoswitch performance with an on/off current ratio up to 4.1 × 105, which is one of the highest values reported for organic materials. It is believed that this method provides a new way to fabricate single crystal arrays and has the potential for application to large area organic electronics. PMID:26282460

  1. Progress in HTS trapped field magnets: J(sub c), area, and applications

    NASA Technical Reports Server (NTRS)

    Weinstein, Roy; Ren, Yanru; Liu, Jianxiong; Sawh, Ravi; Parks, Drew; Foster, Charles; Obot, Victor; Arndt, G. Dickey; Crapo, Alan

    1995-01-01

    Progress in trapped field magnets is reported. Single YBCO grains with diameters of 2 cm are made in production quantities, while 3 cm, 4 1/2 cm and 6 cm diameters are being explored. For single grain tiles: J(sub c) is approximately 10,000 A/cm(exp 2) for melt textured grains; J(sub c) is approximately 40,000 A/cm2 for light ion irradiation; and J(sub c) is approximately 85,000 A/cm(exp 2) for heavy ion irradiation. Using 2 cm diameter tiles bombarded by light ions, we have fabricated a mini-magnet which trapped 2.25 Tesla at 77K, and 5.3 Tesla at 65K. A previous generation of tiles, 1 cm x 1 cm, was used to trap 7.0 Tesla at 55K. Unirradiated 2.0 cm tiles were used to provide 8 magnets for an axial gap generator, in a collaborative experiment with Emerson Electric Co. This generator delivered 100 Watts to a resistive load, at 2265 rpm. In this experiment activation of the TFMs was accomplished by a current pulse of 15 ms duration. Tiles have also been studied for application as a bumper-tether system for the soft docking of spacecraft. A method for optimizing tether forces, and mechanisms of energy dissipation are discussed. A bus bar was constructed by welding three crystals while melt-texturing, such that their a,b planes were parallel and interleaved. The bus bar, an area of approximately 2 cm(exp 2), carried a transport current of 1000 amps, the limit of the testing equipment available.

  2. Numerical simulation of a mini PEMFC stack

    NASA Astrophysics Data System (ADS)

    Liu, Zhixiang; Mao, Zongqiang; Wang, Cheng; Zhuge, Weilin; Zhang, Yangjun

    Fuel cell modeling and simulation has aroused much attention recently because it can probe transport and reaction mechanism. In this paper, a computational fuel cell dynamics (CFCD) method was applied to simulate a proton exchange membrane fuel cell (PEMFC) stack for the first time. The air cooling mini fuel cell stack consisted of six cells, in which the active area was 8 cm 2 (2 cm × 4 cm). With reasonable simplification, the computational elements were effectively reduced and allowed a simulation which could be conducted on a personal computer without large-scale parallel computation. The results indicated that the temperature gradient inside the fuel cell stack was determined by the flow rate of the cooling air. If the air flow rate is too low, the stack could not be effectively cooled and the temperature will rise to a range that might cause unstable stack operation.

  3. High-performance all-solid-state flexible supercapacitors based on two-step activated carbon cloth

    NASA Astrophysics Data System (ADS)

    Jiang, Shulan; Shi, Tielin; Zhan, Xiaobin; Long, Hu; Xi, Shuang; Hu, Hao; Tang, Zirong

    2014-12-01

    A simple and effective strategy is proposed to activate carbon cloth for the fabrication of flexible and high-performance supercapacitors. Firstly, the carbon cloth surface is exfoliated as nanotextures through wet chemical treatment, then an annealing process is applied at H2/N2 atmosphere to reduce the surface oxygen functional groups which are mainly introduced from the first step. The activated carbon cloth electrode shows excellent wettablity, large surface area and delivers remarkable electrochemical performance. A maximum areal capacitance of 485.64 mF cm-2 at the current density of 2 mA cm-2 is achieved for the activated carbon cloth electrode, which is considerably larger than the resported results for carbon cloth. Furthermore, the flexible all-solid-state supercapacitor, which is fabricated based on the activated carbon cloth electrodes, shows high areal capacitance, superior cycling stability as well as stable electrochemical performance even under constant bending or twisting conditions. An areal capacitance of 161.28 mF cm-2 is achieved at the current density of 12.5 mA cm-2, and 104% of its initial capacitance is retained after 30,000 charging/discharging cycles. This study would also provide an effective way to boost devices' electrochemical performance by accommodating other active materials on the activated carbon cloth.

  4. Improving the Fabrication of Semiconductor Bragg Lasers

    NASA Astrophysics Data System (ADS)

    Chen, Eric Ping Chun

    Fabrication process developments for Bragg reflection lasers have been optimized in this thesis using resources available to the group. New e-beam lithography and oxide etch recipes have been developed to minimize sidewall roughness and residues. E-beam evaporated metal contacts for semiconductor diode laser utilizing oblique angle deposition have also been developed in-house for the first time. Furthermore, improvement in micro-loading effect of DFB laser etching has been demonstrated where the ratio of tapered portion of the sidewall to total etch depth is reduced by half, from 33% to 15%. Electrical, optical and thermal performance of the fabricated lasers are characterized. Comparing the results to previous generation lasers, average dynamic resistance is decreased drastically from 14 Ohms to 7 Ohms and threshold current density also reduced from 1705A/cm2 to 1383A/ cm2. Improvement in laser performance is result of reduced loss from optimized fabrication processes. BRL bow-tie tapered lasers is then fabricated for the first time and output power of 18mW at 200mA input is measured. Benefiting from the increased effective area and better carrier utilization, reduction in threshold current density from 1383A/cm 2 to 712A/cm2 is observed.

  5. Topical corticosteroids in the treatment of acute sunburn: a randomized, double-blind clinical trial.

    PubMed

    Faurschou, Annesofie; Wulf, Hans C

    2008-05-01

    To examine the effect of topical corticosteroid treatment on acute sunburn. Randomized, double-blind clinical trial. University dermatology department. Twenty healthy volunteers with Fitzpatrick skin types I (highly sensitive, always burns easily, tans minimally) through III (sun-sensitive skin, sometimes burns, slowly tans to light brown). Seven 34-cm(2) areas were marked on the upper aspect of the back of each participant. An untreated area was tested to determine UV sensitivity. Two areas were treated with excess amounts (2 mg/cm(2)) of either a moderate-potency corticosteroid or a high-potency corticosteroid 30 minutes before UV-B exposure as controls. Six or 23 hours after exposure to radiation, the remaining areas were treated with the 2 corticosteroid preparations. The sunburn improvement factor (SIF) was determined by the following equation: SIF = MED (minimal erythema dose) on treated skin/MED on nontreated skin. An SIF greater than 1 indicated an effect of topical corticosteroids in sunburn relief. The SIFs in the areas treated with either topical corticosteroid 30 minutes before UV-B exposure or high-potency corticosteroid 6 hours after UV-B exposure were significantly different from SIFs in areas that received no treatment (SIF 1.1-1.7; P < .05). Only the median SIF of 1.7 in the areas treated with high-potency corticosteroid 30 minutes before UV-B exposure was clinically relevant. The areas treated 23 hours after UV-B exposure and the areas treated with a moderate-potency corticosteroid 6 hours after UV-B exposure showed no significant reduction in redness. Treatment with topical moderate-potency or high-potency corticosteroids does not provide a clinically useful decrease in the acute sunburn reaction when applied 6 or 23 hours after UV exposure.

  6. Intra-articular calcaneal fractures: effect of open reduction and internal fixation on the contact characteristics of the subtalar joint.

    PubMed

    Mulcahy, D M; McCormack, D M; Stephens, M M

    1998-12-01

    Intra-articular calcaneal fractures are associated with significant long-term morbidity, and considerable controversy exists regarding the optimum method of treating them. The contact characteristics in the intact subtalar joint were determined at known loads and for different positions of the ankle and subtalar joint, using pressure-sensitive film (Super Low; Fuji, Itochu Canada Ltd, Montreal, Quebec). We measured the contact area to joint area ratio (pressure > 5 kg force/cm2 [kgf/cm2]) which normalizes for differences in joint size and the ratio of high pressure zone (>20 kgf/cm2) as a reflection of overall increase in joint pressure. Three simulated fracture patterns were then created and stabilized with either 1 or 2 mm of articular incongruity. Eight specimens were prepared with a primary fracture line through the posterior facet, eight with a joint depression-type fracture, and six with a central joint depression fracture. A measure of 1 to 2 mm of incongruity in the posterior facet for all three fracture patterns produced significant unloading of the depressed fragment, with a redistribution of the overall pattern of pressure distribution to parts of the facet that were previously unloaded.

  7. Effects of wind velocity and slope on fire behavior

    Treesearch

    D.R. Weise; G.S. Biging

    1994-01-01

    Effects of wind velocity and slope on fire spread rate and flame length were examined. Fuel beds of vertical sticks (13.97 cm x 0.455 cm x 0.1 10 cm) and coarse excelsior were burned in an open-topped tilting wind tunnel. Mean fuel moisture content of sticks and excelsior was 11% and 12%, respectively. Mean surface area to volume ratio was 23 cm-! Five slopes (negative...

  8. Effectiveness of Epidural Analgesia, Continuous Surgical Site Analgesia, and Patient-Controlled Analgesic Morphine for Postoperative Pain Management and Hyperalgesia, Rehabilitation, and Health-Related Quality of Life After Open Nephrectomy: A Prospective, Randomized, Controlled Study.

    PubMed

    Capdevila, Xavier; Moulard, Sebastien; Plasse, Christian; Peshaud, Jean-Luc; Molinari, Nicolas; Dadure, Christophe; Bringuier, Sophie

    2017-01-01

    There is no widely recognized effective technique to optimally reduce pain scores and prevent persistent postoperative pain after nephrectomy. We compared continuous surgical site analgesia (CSSA), epidural analgesia (EA), and a control group (patient-controlled analgesic morphine) in patients undergoing open nephrectomy. Sixty consecutive patients were randomized to be part of EA, CSSA, or control groups postoperatively for 72 hours. All patients received patient-controlled analgesic morphine, if needed. Hyperalgesia was assessed on the first, second, and third postoperative days. Chronic pain characteristics and quality of life were analyzed at 1 and 3 months. The primary outcome was the pain score at 24 hours. Secondary outcomes were morphine consumption, postoperative rehabilitation, hyperalgesia, chronic pain incidence, and quality-of-life parameters. At 24 hours, mean ± standard deviation pain values at rest (2.4 ± 1.7, 2.2 ± 1.2, and 4.2 ± 1.2, respectively, in EA, CSSA, and control groups, P <.001) and during coughing was lower in the EA and CSSA groups. Total morphine consumption was higher in the control group. Rehabilitation parameters improved sooner in the EA and CSSA groups. Median values of area of hyperalgesia differed at 48 hours between the EA group and the control group (36.4 cm) and (52 cm) (P = .01) and at 72 hours among the EA group, CSSA group, and the control group (40 cm, 39.5 cm, and 59 cm, respectively; P = .002). CSSA reduced the severity of pain and hyperalgesia at 1 month and optimized quality of life 3 months after surgery (role physical scores, P = .005). CSSA and EA significantly improve postoperative analgesia, reduce postoperative morphine consumption, area of wound hyperalgesia, and accelerate patient rehabilitation after open nephrectomy. CSSA significantly reduces the severity of residual pain 1 month after surgery and optimizes quality-of-life parameters 3 months after surgery.

  9. Variability in effective radiating area and output power of new ultrasound transducers at 3 MHz.

    PubMed

    Johns, Lennart D; Straub, Stephen J; Howard, Samuel M

    2007-01-01

    Spatial average intensity (SAI) is often used by clinicians to gauge therapeutic ultrasound dosage, yet SAI measures are not directly regulated by US Food and Drug Administration (FDA) standards. Current FDA guidelines permit a possible 50% to 150% minimum to maximum range of SAI values, potentially contributing to variability in clinical outcomes. To measure clinical values that describe ultrasound transducers and to determine the degree of intramanufacturer and intermanufacturer variability in effective radiating area, power, and SAI when the transducer is functioning at 3 MHz. A descriptive and interferential approach was taken to this quasi-experimental design. Measurement laboratory. Sixty-six 5-cm(2) ultrasound transducers were purchased from 6 different manufacturers. All transducers were calibrated and then assessed using standardized measurement techniques; SAI was normalized to account for variability in effective radiating area, resulting in an nSAI. Effective radiating area, power, and nSAI. All manufacturers with the exception of Omnisound (P = .534) showed a difference between the reported and measured effective radiating area values (P < .001). All transducers were within FDA guidelines for power (+/-20%). Chattanooga (0.85 +/- 0.05 W/cm(2)) had a lower nSAI (P < .05) than all other manufacturers functioning at 3 MHz. Intramanufacturer variability in SAI ranged from 16% to 35%, and intermanufacturer variability ranged from 22% to 61%. Clinicians should consider treatment values of each individual transducer, regardless of the manufacturer. In addition, clinicians should scrutinize the power calibration and recalibration record of the transducer and adjust clinical settings as needed for the desired level of heating. Our data may aid in explaining the reported heating differences among transducers from different manufacturers. Stricter FDA standards regarding effective radiating area and total power are needed, and standards regulating SAI should be established.

  10. Treatment of oily bilge water by electrocoagulation process using aluminum electrodes

    NASA Astrophysics Data System (ADS)

    Soeprijanto, Perdani, Adela Dea; Nury, Dennis Farina; Pudjiastuti, Lily

    2017-05-01

    Electrocoagulation is electrochemical water and wastewater treatment technology which is the simplest technology using an electrochemical cell where the supply of DC power is applied to the electrodes, made of aluminum metals, and the electrolyte is oily bilge water. The electrocoagulation of oily bilge water was experimentally conducted in a batch system. Aluminum plates with dimensions of 20 cm ×8 cm × 0.2 cm were used for electrodes and mounted vertically with a distance of 4 cm. These electrodes were then connected to the direct current power supply of 10 V and 10 A. The total area of the effective working plate was 160 cm2 when immersed at a depth of 10 cm to the solutions. The results showed that total dissolved Solids (TDS) decreased from 31.2 to 7.54 mg/l and formation of sludge increased up to 12.54 g/l with oil concentration of 50 g/l for 15 min. The largest oil removal of 99.5% was obtained using the initial oil concentration of 55 g/l and the lowest of 96.25% was obtained with the initial oil concentration of 146.04 g/l. A current density of 62.3 mA/cm2 was achieved for a maximum oil removal.

  11. Effects of the led therapy on the global DNA methylation and the expression of Dnmt1 and Dnmt3a genes in a rat model of skin wound healing.

    PubMed

    Gomes, Marcus Vinícius de Matos; Manfredo, Marcelo Henrique; Toffoli, Leandro Vaz; Castro-Alves, Daniellen Christine; do Nascimento, Lucas Magnoni; da Silva, Wyllian Rafael; Kashimoto, Roberto Kiyoshi; Rodrigues, Gelson Marcos; Estrada, Viviane Batista; Andraus, Rodrigo Antonio; Pelosi, Gislaine Garcia

    2016-09-01

    The use of light emitting diodes (LED) as a therapeutic resource for wound healing has increased over the last years; however, little is still known about the molecular pathways associated to LED exposure. In the present study, we verified the effects of LED therapy on DNA methylation and expression of the DNA methyltransferase (Dnmt) genes, Dnmt1 and Dnmt3a, in an in vivo model of epithelial wound healing. Male Wistar rats were submitted to epithelial excision in the dorsal region and subsequently distributed within the experimental groups: group 1, animals that received irradiation of 0.8 J/cm(2) of LED (604 nm); group 2, animals that received 1.6 J/cm(2) of LED (604 nm); control (CTL), animals not submitted to therapeutic intervention. LED applications were performed during 7 days, and tissues from the periphery of the wound area were obtained for molecular analysis. The Image-J software was used for analysis of the wound area. DNA methylation was evaluated by ELISA-based method and gene expressions were quantified by real-time PCR. Decrease on global DNA methylation profile was observed in all experimental groups (CTL, 1, and 2) revealing the participation of DNA methylation in the healing process. Significant decrease in the wound area accompanied by increase in the Dnmt3a expression was associated to group 2. Based on our findings, we propose that DNA methylation is an important molecular mechanism associated to wound healing and that irradiation with 1.6 J/cm(2) of LED evokes an increase in the expression of the Dnmt3a that might associates to the efficiency of the epithelial wound healing.

  12. 250-W RF-excited slab CO2 lasers using gold catalyst

    NASA Astrophysics Data System (ADS)

    Kyun, V. V.; Samorodov, V. G.; Shishkanov, E. F.

    2003-11-01

    The investigations and constructions of compact RF-excitation CO2 lasers with slab discharge channel geometry and unstable-waveguide resonators are described. The output average power scale up to 260 W from electrode area of 198 cm2 have been obtained in sealed-off mode because use a catalyst effect in discharge volume.

  13. [The cross-sectional area of the median nerve by sonography in the diagnosis of carpal tunnel syndrome].

    PubMed

    Sabag-Ruiz, Enrique; Higuera-Lugo, Cirilo Omar; Ornelas-Aguirre, José Manuel; Gómez-Alcalá, Alejandro V

    2009-01-01

    To measure the median nerve cross-sectional area (MNCSA) at the carpal tunnel (CT) level by sonography (S) in a Mexican population. A comparative cross-sectional design study with a nonprobabilistic sampling with 50 women and 50 men in good health were submitted for measuring MNCSA at the level of the CT. Other variables like sex; side and degree of daily hand activity were also studied. The analysis was made by descriptive statistics, and Mann-Whitney U or Kruskal-Wallis tests. The mean MNCSA was 0.063 +/- 0.015 cm(2), in women; in men it was 0.072 +/- 0.018 cm(2); the difference was significant (p < 0.004). The median MNCSA among women was 0.062 cm(2) in the right side and 0.060 cm(2) in the left (90th percentile for both hands of 0.084 cm(2)); in men, it was of 0.070 cm(2) in the right hand and of 0.069 cm(2) in the left (90th percentile for both hands of 0.097 cm(2)). The difference between women and men was significant in each side, but not between right and left hands (p = 0.21). There was no correlation between age and MNCSA on either side, or with hand activity. A MNCSA value of 0.1 cm(2) for men and 0.09 cm(2) for women is proposed as a standard parameter for the Mexican population.

  14. Photomatrix LED therapy of extensive cutaneous pathology

    NASA Astrophysics Data System (ADS)

    Zharov, Vladimir P.; Menyaev, Yulian A.; Zharova, I. Z.; Leviev, Dmitry O.; Tsarev, V. N.; Sarantsev, V. P.; Krusic, Joze

    2000-05-01

    Standard sources of radiation have not sufficient efficiency at treating spatially extended pathology, especially when pathologic areas involve opposite sides of the human being's body or when they are uneven in shape. The typical examples of such pathology are extensive burns, oedema, inflammatory processes, infectious wounds, actinic keratosis, psoriasis, arthritis and neurological diseases. Superbright LEDs gathered in a matrix and grasping the area of irradiation are the most suitable sources of radiation. This article presents the result of investigation of the effectiveness of various types of the blue-to-infrared spectrum range LED array that allow irradiating a surface with an area from several cm2 to several thousand cm2 including the whole human being's body with the intensity varying from 1 to 100 mW/cm2. Besides the matrixes, composed of separate light diodes, modular systems with separate monolithic hybrid chips with a high density of positioning the sources of radiation are considered. The peculiarities and results of applying such systems to treat oedema, cancer, weight regulation, neurological diseases, different infections diseases in combination with PDT, stomatitis and paradontosis are analyzed. The parameters of the photomatrix LED for different spectral regions and different geometry from flat shape to semispherical and cylindrical are presented. The perspective combination photomatrix LED with another therapeutical devices including photovacuum and photomagnetic therapy are considered.

  15. 10 CFR 835.205 - Determination of compliance for non-uniform exposure of the skin.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 100 cm 2 or more. The non-uniform equivalent dose received during the year shall be averaged over the... irradiated is 10 cm 2 or more, but is less than 100 cm 2. The non-uniform equivalent dose (H) to the... less than 0.1 be used. (3) Area of skin irradiated is less than 10 cm 2. The non-uniform equivalent...

  16. 10 CFR 835.205 - Determination of compliance for non-uniform exposure of the skin.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 100 cm 2 or more. The non-uniform equivalent dose received during the year shall be averaged over the... irradiated is 10 cm 2 or more, but is less than 100 cm 2. The non-uniform equivalent dose (H) to the... less than 0.1 be used. (3) Area of skin irradiated is less than 10 cm 2. The non-uniform equivalent...

  17. 10 CFR 835.205 - Determination of compliance for non-uniform exposure of the skin.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 100 cm 2 or more. The non-uniform equivalent dose received during the year shall be averaged over the... irradiated is 10 cm 2 or more, but is less than 100 cm 2. The non-uniform equivalent dose (H) to the... less than 0.1 be used. (3) Area of skin irradiated is less than 10 cm 2. The non-uniform equivalent...

  18. 10 CFR 835.205 - Determination of compliance for non-uniform exposure of the skin.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 100 cm 2 or more. The non-uniform equivalent dose received during the year shall be averaged over the... irradiated is 10 cm 2 or more, but is less than 100 cm 2. The non-uniform equivalent dose (H) to the... less than 0.1 be used. (3) Area of skin irradiated is less than 10 cm 2. The non-uniform equivalent...

  19. 10 CFR 835.205 - Determination of compliance for non-uniform exposure of the skin.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 100 cm 2 or more. The non-uniform equivalent dose received during the year shall be averaged over the... irradiated is 10 cm 2 or more, but is less than 100 cm 2. The non-uniform equivalent dose (H) to the... less than 0.1 be used. (3) Area of skin irradiated is less than 10 cm 2. The non-uniform equivalent...

  20. Right Ventricular Tissue Doppler Assessment in Space During Circulating Volume Modification using the Braslet-M Device

    NASA Technical Reports Server (NTRS)

    Hamilton, D. R.; Sargsyan, A. E.; Fincke, E. M.; Magnus, S. H.; Lonchakov, Y. V.; Alferova, I. V.; Dulchavsky, S. A.; Ebert, D.; Garcia, K.; Martin, D.; hide

    2009-01-01

    This joint U.S. - Russian work aims to establish a methodology for assessing cardiac function in microgravity in association with manipulation of central circulating volume. Russian Braslet-M occlusion cuffs were used to temporarily increase the volume of blood in the lower extremities, which effectively reduces the volume returning to the heart in the central circulation. A novel methodology was tested on the International Space Station (ISS) to assess the volume status of crewmembers by evaluating the responses to application and release of the Braslet-on-occlusion cuffs, as well as to modified Valsalva and Mueller maneuvers. Baseline echocardiographic tissue Doppler imaging (TDI) of the right ventricular free wall with no Braslet applied shows early diastolic E' (16 cm/sec), late diastolic A' (14 cm/sec), and systolic (12 cm/sec) velocities compatible with normal subjects on Earth. TDI of the RV free wall with Braslet applied shows that early diastolic E' decreased by 50% (8 cm/sec), late diastolic A' increased by 45%, and systolic S' remains unchanged. TDI of the RV free wall approximately 8 beats after the Braslet was released shows early diastolic E' (8 cm/sec), late diastolic A' (12 cm/sec), and systolic S' (13 cm/sec) velocities. During this portion of the release, early diastolic E' did not recover to baseline values but late diastolic A' and systolic S' recovered to pre-Braslet values. The pre-systolic cross-sectional area of the internal jugular vein with Braslet off was 1.07 cm(sup 2) and 1.13 cm(sup 2) 10 min after the Braslet was applied. The presystolic cross-sectional area of the common femoral vein with Braslet off was 0.50 cm(sup 2), and was 0.54 cm(sup 2) 10 min after the Braslet was applied. The right ventricular myocardial performance Tei index also was calculated for comparison with typical values found in healthy subjects on Earth. Baseline and Braslet-on values for Tei index were 0.25 and 0.22 respectively. Braslet Tei indices are within normal ranges found in healthy subjects and temporarily become greater than 0.4 during the dynamic Braslet release portion of this study. Tissue Doppler imaging of the right ventricle revealed that the Braslet influenced cardiac preload and that fluid was sequestered in the lower-extremity interstitial and vascular space after only 10 minutes of application. This report demonstrates that Braslet application affects right ventricular physiology in long-duration space flight based on TDI and that this effect is in part due to venous hemodynamics.

  1. Raman spectroscopic study of leptospiral glycolipoprotein

    NASA Astrophysics Data System (ADS)

    Bao, PeiDi; Bao, Lang; Huang, TianQuan; Liu, XinMing

    1998-04-01

    The Raman scattering spectra of two different samples of Leptospiral Glycoipoprotein (GLP-1 and GLP-2) which have different toxic effects have been obtained and investigated. Leptospirosis is one of the most harmful zoonosis. It is a serious public health issue in some area of Sichusan province. The two samples offer different structural informations of GLP molecules, it would be important to find the difference in contents, structures and the amino acid side - chains environment of the molecules between the two samples of GLP for understanding the different toxic effects. The intense Am I at 1651 cm-1 and weak Am III at 1283 cm-1 show that GLP-1 has a predominantly (alpha) -helix secondary structure. The intense Am I at 1674 cm-1 and intense Am III at 1246 cm-1 show that the conformation of GLP-2 has a high content of (Beta) - sheet and a low content of random - coil secondary structure. Strong Raman scattering occurs in the range 920- 980 cm-1, belong to the C-COO vibration and the stretching of the peptide backbone. The molecules of GLP-1 has trans-gauche-trans configuration of the C-S-S-C-C linkage and the molecules of GLP-2 has trans-gauche-gauche configuration of the C-C-S-S-C-C linkage. The intensity ratio of the two tyrosine liens at 830 cm-1 and 850 cm-1 is 1.1 and 1.23, indicate their tyrosine reduces environment respectively. Other side-chain environment in the two samples were discussed.

  2. Evaluation of a New Environmental Sampling Protocol for Detection of Human Norovirus on Inanimate Surfaces

    PubMed Central

    Lee, David; Treffiletti, Aimee; Hrsak, Mario; Shugart, Jill; Vinjé, Jan

    2015-01-01

    Inanimate surfaces are regarded as key vehicles for the spread of human norovirus during outbreaks. ISO method 15216 involves the use of cotton swabs for environmental sampling from food surfaces and fomites for the detection of norovirus genogroup I (GI) and GII. We evaluated the effects of the virus drying time (1, 8, 24, or 48 h), swab material (cotton, polyester, rayon, macrofoam, or an antistatic wipe), surface (stainless steel or a toilet seat), and area of the swabbed surface (25.8 cm2 to 645.0 cm2) on the recovery of human norovirus. Macrofoam swabs produced the highest rate of recovery of norovirus from surfaces as large as 645 cm2. The rates of recovery ranged from 2.2 to 36.0% for virus seeded on stainless-steel coupons (645.0 cm2) to 1.2 to 33.6% for toilet seat surfaces (700 cm2), with detection limits of 3.5 log10 and 4.0 log10 RNA copies. We used macrofoam swabs to collect environmental samples from several case cabins and common areas of a cruise ship where passengers had reported viral gastroenteritis symptoms. Seventeen (18.5%) of 92 samples tested positive for norovirus GII, and 4 samples could be sequenced and had identical GII.1 sequences. The viral loads of the swab samples from the cabins of the sick passengers ranged from 80 to 31,217 RNA copies, compared with 16 to 113 RNA copies for swab samples from public spaces. In conclusion, our swab protocol for norovirus may be a useful tool for outbreak investigations when no clinical samples are available to confirm the etiology. PMID:26116675

  3. [Responses of soil organic carbon and its labile fractions to nitrogen and phosphorus additions in Cunninghamia lanceolata plantations in subtropical China.

    PubMed

    Zhang, Xiu Lan; Wang, Fang Chao; Fang, Xiang Min; He, Ping; Zhang, Yu Fei; Chen, Fu Sheng; Wang, Hui Min

    2017-02-01

    A series of nitrogen (N) and phosphorus (P) addition experiments using treatments of N 0 (0 kg N·hm -2 ·a -1 ), N 1 (50 kg N·hm -2 ·a -1 ), N 2 (100 kg N·hm -2 ·a -1 ), P (50 kg P·hm -2 ·a -1 ), N 1 P and N 2 P were conducted at Cunninghamia lanceolata plantations in subtropical China. The responses of soil organic carbon (SOC), particulate organic carbon (POC) and water-soluble organic carbon (WSOC) to the nutrient addition treatments after 3 years were determined. The results showed that N and P additions had no significant effects on SOC concentration in 0-20 cm soil layer, while P addition significantly decreased soil POC content in 0-5 cm soil layer by 26.1%. The responses of WSOC to N and P addition were mainly found in 0-5 cm soil layer, and low level N and P addition significantly increased the WSOC content in 0-5 cm soil layer. Nitrogen addition had no significant effect on POC/SOC, while the POC/SOC significantly decreased by 15.9% in response to P addition in 0-5 cm soil layer. In 5-10 cm and 10-20 cm soil layers, POC/SOC was not significantly altered in N and P addition treatments. Therefore, the forest soil C stability was mainly controlled by P content in subtropical areas. P addition was liable to cause the decomposition of surface soil active organic C and increased the soil C stability in the short term treatment.

  4. Effects of crop load on distribution and utilization of 13C and 15N and fruit quality for dwarf apple trees.

    PubMed

    Ding, Ning; Chen, Qian; Zhu, Zhanling; Peng, Ling; Ge, Shunfeng; Jiang, Yuanmao

    2017-10-26

    In order to define the effects of fruit crop load on the distribution and utilization of carbon and nitrogen in dwarf apple trees, we conducted three crop load levels (High-crop load, 6 fruits per trunk cross-sectional area (cm 2 , TCA)), Medium-crop load (4 fruits cm -2 TCA), Low-crop load (2 fruits cm -2 TCA)) in 2014 and 2015. The results indicated that the 15 N derived from fertilizer (Ndff) values of fruits decreased with the reduction of crop load, but the Ndff values of annual branches, leaves and roots increased. The plant 15 N-urea utilization rates on Medium and Low-crop load were 1.12-1.35 times higher than the High-crop load. With the reduction of crop load, the distribution rate of 13 C and 15 N in fruits was gradually reduced, but in contrast, the distribution of 13 C and 15 N gradually increased in annual branches, leaves and roots. Compared with High-crop load, the Medium and Low-crop load significantly improved fruit quality p < 0.05. Hence, controlling fruit load effectively regulated the distribution of carbon and nitrogen in plants, improved the nitrogen utilization rate and fruit quality. The appropriate crop load level for mature M.26 interstocks apple orchards was deemed to be 4.0 fruits cm -2 TCA.

  5. Whispering--a single-subject study of glottal configuration and aerodynamics.

    PubMed

    Sundberg, Johan; Scherer, Ronald; Hess, Markus; Müller, Frank

    2010-09-01

    Whisper productions were produced by a single adult male subject over a wide range of subglottal pressures, glottal areas, and glottal flows. Dimensional measurements were made of these three variables, including glottal perimeter. Subglottal pressure was directly obtained by a pressure transducer in a tracheal catheter, and wide-band flow with a pneumotach mask. Four types of whispers were used-hyperfunctional, hypofunctional, neutral, and postphonation-in addition to three levels of loudness (soft, medium, loud). Sequences of the /pae/ syllable were used. Video recordings of the larynx were made. The glottis was outlined by hand with extrapolation for unseen parts, and area and perimeter were obtained through image analysis software. The whisper tokens resulted in the following wide ranges: subglottal pressure: 1.3-17 cm H2O; glottal flow: 0.9-1.71 L/s; glottal area: 0.065-1.76 m2; and glottal perimeter: 1.09-6.55 cm. Hyperfunctional whisper tended to have higher subglottal pressures and lower areas and flows than hypofunctional whisper, with neutral and postphonation whisper values in between. An important finding is that glottal flow changed more for small changes of area when the area was already small, and did not create much flow change when area was changed for already larger areas; that is, whisper is "more sensitive" to airflow changes for smaller glottal areas. A general equation for whisper aerodynamics was obtained, namely, P (subglottal pressure [cm H2O])=C X F (glottal flow [cm(3)/s]), where C = 0.052 x A(4) - 0.1913 x A(3) + 0.2577 x A(2) - 0.1523 x A+0.0388, where A is the glottal area (cm(2)). Another general equation for nondimensional terms (pressure coefficient vs Reynolds number) also is offered. Implications for whisper flow resistance and aerodynamic power are given. These results give insight into whisper aerodynamics and offer equations relevant to speech synthesis. Copyright © 2010 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  6. Effect of Low-Level Laser Therapy and Strength Training Protocol on Hand Grip by Dynamometry

    PubMed Central

    Barbosa, Rafael; Marcolino, Alexandre; Souza, Vitor; Bertolino, Guilherme; Fonseca, Marisa; Guirro, Rinaldo

    2017-01-01

    Introduction: The purpose of this study was to investigate the effect of low-level laser therapy (LLLT) – 660 nm and 904 nm - before grip strength protocol in healthy subjects. Methods: The study included 45 healthy volunteers with an average age of 22.7 (±1.4) years, subdivided into the following groups, control group: grip strength training associated with placebo LLLT; 660 nm group: LLLT (660 nm, 20 J/cm2, power of 30 mW, and beam area of 0.06 cm2, continuous, energy 1.2 J, and exposure time 40 seconds per point) before grip strength training and 904 nm group: LLLT (904 nm, 10 J/cm2, peak power of 70 W and 0.13 cm2 beam area, with pulsed beam 9.500 Hz and 30 seconds of exposure time per point and emitted energy 1.2 J) before grip strength training. The LLLT was timed to contact 10 points located in the region of the superficial and deep flexor muscles of the fingers, with a total energy of 12.0 J per session. For the strength training protocol, the volunteer exercised their fingers with the dominant hand on a small table, elbow flexed at 90°, forearm in neutral, using a light extension handle. The Oxford protocol was performed during four weeks. The grip strength was assessed using a dynamometer (Jamar™). The data were evaluated by the analysis of variance (ANOVA) statistical method. Results: In the comparison of intragroup evaluation, only the 904 nm group showed a difference compared to the baseline assessment after 4 weeks (P < 0.05), in the final intergroup evaluation, a difference was observed in the comparison between the control and 904 nm groups Conclusion: In conclusion, LLLT (904 nm) applied before resistance training was effective in gaining grip strength when compared to LLLT (660 nm) and isolated strength training after 4 weeks. PMID:29123629

  7. Effects of positive end-expiratory pressure titration and recruitment maneuver on lung inflammation and hyperinflation in experimental acid aspiration-induced lung injury.

    PubMed

    Ambrosio, Aline M; Luo, Rubin; Fantoni, Denise T; Gutierres, Claudia; Lu, Qin; Gu, Wen-Jie; Otsuki, Denise A; Malbouisson, Luiz M S; Auler, Jose O C; Rouby, Jean-Jacques

    2012-12-01

    In acute lung injury positive end-expiratory pressure (PEEP) and recruitment maneuver are proposed to optimize arterial oxygenation. The aim of the study was to evaluate the impact of such a strategy on lung histological inflammation and hyperinflation in pigs with acid aspiration-induced lung injury. Forty-seven pigs were randomly allocated in seven groups: (1) controls spontaneously breathing; (2) without lung injury, PEEP 5 cm H2O; (3) without lung injury, PEEP titration; (4) without lung injury, PEEP titration + recruitment maneuver; (5) with lung injury, PEEP 5 cm H2O; (6) with lung injury, PEEP titration; and (7) with lung injury, PEEP titration + recruitment maneuver. Acute lung injury was induced by intratracheal instillation of hydrochloric acid. PEEP titration was performed by incremental and decremental PEEP from 5 to 20 cm H2O for optimizing arterial oxygenation. Three recruitment maneuvers (pressure of 40 cm H2O maintained for 20 s) were applied to the assigned groups at each PEEP level. Proportion of lung inflammation, hemorrhage, edema, and alveolar wall disruption were recorded on each histological field. Mean alveolar area was measured in the aerated lung regions. Acid aspiration increased mean alveolar area and produced alveolar wall disruption, lung edema, alveolar hemorrhage, and lung inflammation. PEEP titration significantly improved arterial oxygenation but simultaneously increased lung inflammation in juxta-diaphragmatic lung regions. Recruitment maneuver during PEEP titration did not induce additional increase in lung inflammation and alveolar hyperinflation. In a porcine model of acid aspiration-induced lung injury, PEEP titration aimed at optimizing arterial oxygenation, substantially increased lung inflammation. Recruitment maneuvers further improved arterial oxygenation without additional effects on inflammation and hyperinflation.

  8. Snare-assisted anterograde balloon mitral and aortic valvotomy using Inoue balloon catheter.

    PubMed

    Krishnan, Mangalath N; Syamkumar, M D; Sajeev, C G; Venugopal, K; Johnson, Francis; Vinaykumar, D; Velayudhan, C C; Jayakumar, T G

    2007-01-02

    We performed concurrent antegrade mitral and aortic valvotomy using Inoue dilatation catheter in 3 cases of combined rheumatic mitral and aortic stenosis. Following mitral valvotomy by standard procedure, aortic valve was crossed with the help of a floatation catheter. Stiff long length guide wire was fixed in descending aorta using a snare. Inoue catheter was threaded over the wire across the aortic valve and aortic valvotomy completed. Mitral valve area increased from mean 1 cm2 to 2 cm2; aortic gradient dropped from mean of 97 mm to 36 mm. Concurrent anterograde balloon mitral and aortic valvotomy may be effective and safe.

  9. Association of subcutaneous and visceral fat mass with serum concentrations of adipokines in subjects with type 2 diabetes mellitus.

    PubMed

    Saito, Tomoyuki; Murata, Miho; Otani, Taeko; Tamemoto, Hiroyuki; Kawakami, Masanobu; Ishikawa, San-E

    2012-01-01

    The goal of the study was to examine the association of subcutaneous and visceral fat mass with serum concentrations of adipokines in 130 subjects with type 2 diabetes mellitus. The levels of serum high sensitivity C-reactive protein (HS-CRP), adiponectin, high-molecular-weight (HMW) adiponectin, interleukin-18, and retinol-binding protein 4 were measured. Percentage body fat was determined by dual energy X-ray absorptiometry, and subcutaneous and visceral fat areas were measured by abdominal CT. HS-CRP had significant positive correlations with percentage body fat and subcutaneous fat area, and a particularly significant positive correlation with visceral fat area. Serum adiponectin had a negative correlation with the subcutaneous and visceral fat areas, with the strongest correlation with the visceral fat area. Similar results were obtained for HMW adiponectin. Serum adiponectin had a negative correlation with visceral fat area in subjects with a visceral fat area < 100 cm², but not in those with a visceral fat area ≥ 100 cm². In contrast, serum HS-CRP showed a positive correlation with visceral fat area in subjects with visceral fat area ≥ 100 cm², but not in those with a visceral fat area < 100 cm². These findings indicate that an increased visceral fat area is associated with inflammatory changes, and that inflammatory reactions may alter the functional properties of visceral fat in type 2 diabetes mellitus.

  10. [Two compartment model of body composition and abdominal fat area in postmenopausal women - pilot study].

    PubMed

    Milewska, Magdalena; Mioduszewska, Milena; Pańczyk, Mariusz; Kucharska, Alicja; Sińska, Beata; Dąbrowska-Bender, Marta; Michota-Katulska, Ewa; Zegan, Magdalena; Szabla, Anna

    2016-01-01

    Both menopausal period and aging have influence on body composition, increase of total body fat and visceral fat in particular. We should be aware that changes in body composition, mainly fat translocation to abdominal region, can occur without significant changes in body weight. Therefore quantitative abdominal fat assessment should be our aim. Body composition analysis based on two compartment model and abdominal fat area assessment in cross section. Subjects in postmenopausal period (41 women) were recruited for this study and divided into 2 groups: group 1 - women aged 45-56 years and group 2 - women aged 57-79 years. Body composition analysis and abdominal fat area assessment were conducted by using bioelectrical impedance method with BioScan 920 (Maltron int.) accordingly with standardized procedure. Women in early postmenopausal stage (Group 1) had statistically significant lower total body fat percentage in comparison with women in late postmenopausal period (Group 2) (41.09 ± 7.72% vs. 50.7 ± 9.88%, p=0.0021). Also women in group 1 were characterized by significant lower visceral fat area (VAT) as well as subcutaneous fat area (SAT) in comparison with group 2 (respectively VAT 119.25 ± 30.09 cm2 vs. 199.36 ± 87.38 cm2, p=0.0011; SAT 175.19 ±57.67 cm2 vs. 223.4±74.29 cm2, p=0.0336). According to VAT criteria (>120 cm2), 44% of women in group 1 and 80% in group 2 had excess of visceral fat. Both total body fat and intra-abdominal fat increased with age, independently of weight changes.

  11. Effects of DanceSport on walking balance and standing balance among the elderly.

    PubMed

    Sohn, Jeehoon; Park, Sung-Ha; Kim, Sukwon

    2018-05-04

    Dancesport is a popular activity among older adults who look for fun and fitness in Korea. Studies reported positive sociological and psychological effects of dancesport. But, little studies were performed to evaluate the effects of dancesport on balance performances. The objective of the present study was to evaluate the effects of dancesport for 15 weeks on walking balance and standing balance of older adults. Older adults regularly participated in the dancesport program 3 times a week for 15 weeks. The program included Rumba, Cha-cha-cha, and Jive. They exercised the prescribed dancesport at intermediate level for 50-60 mins for each time. A total 22 reflective markers were placed on the anatomical landmarks and 8 cameras were used to measure 3-D positions of participants. Also, center of pressure (COP) data were measured to analyze standing balance using a ground reaction board at 1200 Hz for 30 seconds. One-way analysis of variance (ANOVA) was performed to test the effects of 15 weeks of dancesport on walking balance and standing balance. The results suggested that, after 15 weeks of dancesport participation, older adults' walking balance (48.3 ± 20.3 cm2 vs 38.2 ± 18.2 cm2) and standing balance (COP area: 189.4 ± 85.4 mm2 vs 103.5 ± 55.4mm2, COP distance: 84.2 ± 34.4 cm vs 76.5 ± 21.4 cm) were significantly improved. Performing dancesport would require moving center of mass rapidly and frequently while maintaining posture. This may result in improving walking balance and standing balance in the present study. The study concluded that dancesport would be an effective exercise method in enhancing postural stability of older adults.

  12. Comments on shielding for dual energy accelerators.

    PubMed

    Rossi, M C; Lincoln, H M; Quarin, D J; Zwicker, R D

    2008-06-01

    Determination of shielding requirements for medical linear accelerators has been greatly facilitated by the publication of the National Council on Radiation Protection and Measurements (NCRP) latest guidelines on this subject in NCRP Report No. 151. In the present report the authors review their own recent experience with patient treatments on conventional dual energy linear accelerators to examine the various input parameters needed to follow the NCRP guidelines. Some discussion is included of workloads, occupancy, use factors, and field size, with the effects of intensity modulated radiotherapy (IMRT) treatments included. Studies of collimator settings showed average values of 13.1 x 16.2 cm2 for 6 MV and 14.1 x 16.8 cm2 for 18 MV conventional ports, and corresponding average unblocked areas of 228 and 254 cm2, respectively. With an average of 77% of the field area unblocked, this gives a mean irradiated area of 196 cm2 for the 18 MV beam, which dominates shielding considerations for most dual energy machines. Assuming conservatively small room dimensions, a gantry bin angle of 18 degrees was found to represent a reasonable unit for tabulation of use factors. For conventional 18 MV treatments it was found that the usual treatment angles of 0, 90, 180, and 270 degrees were still favored, and use factors of 0.25 represent reasonable estimates for these beams. As expected, the IMRT fields (all at 6 MV) showed a high degree of gantry angle randomization, with no bin having a use factor in excess of 0.10. It is concluded that unless a significant number of patients are treated with high energy IMRT, the traditional use factors of 0.25 are appropriate for the dominant high energy beam.

  13. The effect of break of runoff connectivity on SOC concentration in loess catchment of the Lublin Upland (Poland)

    NASA Astrophysics Data System (ADS)

    Rejman, Jerzy; Rafalska-Przysucha, Anna; Paluszek, Jan

    2014-05-01

    Soil erosion processes lead to redistribution of soils and soil organic carbon (SOC) in the landscape. In this study, we aimed to evaluate the effect of runoff connectivity on horizontal and vertical SOC concentration in the catchment. SOC concentration was examined in a small agricultural catchment located in deep loess area of the Lublin Upland, Poland (51019'55"N, 22023'16"E). The catchment area of 5.6 ha is divided into 11 parcels. Conventional tillage is performed on each of the parcel and plow includes of 1-2 moldboard and 1 cultivator operations per year. Tillage is performed along the longest side of parcels. Crop rotation includes wheat, barley, sugar beets, potatoes and maize. Connectivity of temporal overland flow in the catchment is disturbed by grassed borders of the parcels. SOC concentration was studied in 151 sampling points in a grid 20 by 20 m. Structure of soil profile was studied in each of the sampling points, and soil cores were taken from two soil layers of 0-25 and 25-50 cm, and from 7 profiles located within the closed depression and the areas where line of temporary overland flow cross the grassed parcel borders. SOC concentration in soil samples was determined by wet combustion with dichromate solution. Depositional soils represented 57 profiles in the catchment. The thickness of accumulated soil layer varied from 20 to 151 cm with a mean of 55 cm. SOC concentration ranged from 8.4 to 15.0 g kg-1 (with a mean of 11.0 g kg-1) in the upper and from 2.9 to 14.5 g kg-1 (7.5) in the deeper soil layer. Coefficient of variation was 12.9% in the layer 0-25 cm, and 44.5% in the layer 25-50 cm. To find the reasons of high variability of SOC concentration in deeper soil layer, the location of depositional soils in the catchment was analyzed. The analysis enabled to distinguish two groups of depositional soils of different SOC concentration at the depth of 25-50 cm. Depositional soils located in the zones of temporal stagnation of overland flow (i.e. closed depressions and the areas where the lines of concentrated flow cross the parcel borders) characterized higher SOC concentration with a mean of 10.10 g kg-1, and depositional soils located on slopes - lower (4.10 g kg-1). The first group represented 33 profiles, the second 24. Coefficient of variation in each group of soil was 19%. Vertical SOC concentration showed a large variation in profiles of depositional soils, with layers of higher and smaller SOC concentration at different depth. Soils located in the zones where lines of concentrated temporary flow cross the field borders showed a high SOC enrichment in buried Ab horizons (at the depth >80 cm) in comparison to soils located in closed depressions. The difference could be a result of larger area that contributes to overland flow in the case of sites located at lines of flow in comparison to the contribution area of closed depressions. The exception is a profile SP6, where the SOC concentration in Ab is similar to the Ab horizon in depressions. The SP6 profile is located in the lower part of the catchment at the end of a parcel of the length of 110 m. The other profiles (SP2, and SP5) are in the areas were distance between the parcel borders is 40-60 m, and SP7 is at the catchment outlet. It seems that the difference in SOC concentration in Ab between SP6 and SP2-SP5 is a result of more effective decrease of velocity of overland flow by closely located grassed borders of the parcels. The studies showed that grassed parcel borders fill an effective role in an increase of soil carbon stock in the areas where lines of temporary overland flow cross the parcel border. The effectiveness of SOC accumulation was larger in the past, as it is proved by high SOC concentration in buried Ab horizon, and was dependent on the distance between the grassed borders.

  14. Fabrication and characterization of AlN metal-insulator-semiconductor grown Si substrate

    NASA Astrophysics Data System (ADS)

    Mahyuddin, A.; Azrina, A.; Mohd Yusoff, M. Z.; Hassan, Z.

    2017-11-01

    An experimental investigation was conducted to explore the effect of inserting a single AlGaN interlayer between AlN epilayer and GaN/AlN heterostructures on Si (111) grown by molecular beam epitaxy (MBE). It is confirmed from the scanning electron microscopy (SEM) that the AlGaN interlayer has a remarkable effect on reducing the tensile stress and dislocation density in AlN top layer. Capacitance-voltage (C-V) measurements were conducted to study the electrical properties of AlN/GaN heterostructures. While deriving the findings through the calculation it is suggested that the AlGaN interlayer can significantly reduce the value of effective oxide charge density and total effective number of charges per unit area which are 1.37 × 10-6C/cm2 and 8.55 × 1012cm-2, respectively.

  15. EFFECTIVE DOSE IN TWO DIFFERENT DENTAL CBCT SYSTEMS: NEWTOM VGi AND PLANMECA 3D MID.

    PubMed

    Ghaedizirgar, Mohammad; Faghihi, Reza; Paydar, Reza; Sina, Sedigheh

    2017-11-01

    Cone beam computed tomography, CBCT, is a kind of CT scanner producing conical diverging X-rays, in which a large area of a two-dimensional detector is irradiated in each rotation. Different investigations have been performed on dosimetry of dental CBCT. As there is no special protocol for dental CBCT, CT scan protocols are used for dosimetry. The purpose of this study is measurement of dose to head and neck organs in two CBCT systems, i.e. Planmeca 3D Mid (PM) and NewTom VGi (NT), using thermoluminescence dosimetry and Rando phantom. The thermoluminescent dosimetry (TLD)-100 chips were put at the position of different organs of the head and neck. Two TLD-100 chips were inserted at each position, the dose values were measured for several different field sizes, i.e. 8 × 8, 12 × 8 and 15 × 15 cm2 for NewTom, and 10 × 10 and 20 × 17 cm2 for Planmeca systems. According to the results, the average effective dose in PM is much more than the NT system in the same field size, because of the greater mAs values. For routine imaging protocols used for NT, the effective dose values are 70, 73 and 121 µSv for 8 × 8, 12 × 8 and 15 × 15 cm2 field sizes, respectively. In PM, the effective dose in 10 × 10 cm2 and 17 × 20 cm2 is 259 and 341 µSv, respectively. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. The effect of holes in long-lasting insecticidal nets on malaria in Malawi: results from a case-control study.

    PubMed

    Minta, Anna A; Landman, Keren Z; Mwandama, Dyson A; Shah, Monica P; Eng, Jodi L Vanden; Sutcliffe, James F; Chisaka, Joseph; Lindblade, Kim A; Mathanga, Don P; Steinhardt, Laura C

    2017-10-02

    Long-lasting insecticidal nets (LLINs) are a cornerstone of malaria prevention. Holes develop in LLINs over time and compromise their physical integrity, but how holes affect malaria transmission risk is not well known. After a nationwide mass LLIN distribution in July 2012, a study was conducted to assess the relationship between LLIN damage and malaria. From March to September 2013, febrile children ages 6-59 months who consistently slept under LLINs (every night for 2 weeks before illness onset) were enrolled in a case-control study at Machinga District Hospital outpatient department. Cases were positive for Plasmodium falciparum asexual parasites by microscopy while controls were negative. Digital photographs of participants' LLINs were analysed using an image-processing programme to measure holes. Total hole area was classified by quartiles and according to the World Health Organization's proportionate hole index (pHI) cut-offs [< 79 cm 2 (good), 80-789 cm 2 (damaged), and > 790 cm 2 (too torn)]. Number of holes by location and size, and total hole area, were compared between case and control LLINs using non-parametric analyses and logistic regression. Of 248 LLINs analysed, 97 (39%) were from cases. Overall, 86% of LLINs had at least one hole. The median number of holes of any size was 9 [interquartile range (IQR) 3, 22], and most holes were located in the lower halves of the nets [median 7 (IQR 2, 16)]. There were no differences in number or location of holes between LLINs used by cases and controls. The median total hole area was 10 cm 2 (IQR 2, 125) for control LLINs and 8 cm 2 (IQR 2, 47) for case LLINs (p = 0.10). Based on pHI, 109 (72%) control LLINs and 83 (86%) case LLINs were in "good" condition. Multivariable modeling showed no association between total hole area and malaria, controlling for child age, caregiver education, and iron versus thatched roof houses. LLIN holes were not associated with increased odds of malaria in this study. However, most of the LLINs were in relatively good condition 1 year after distribution. Future studies should examine associations between LLIN holes and malaria risk with more damaged nets.

  17. Shallow magma system of Kilauea volcano investigated using L-band synthetic aperture radar data

    NASA Astrophysics Data System (ADS)

    Fukushima, Y.; Sinnett, D. K.; Segall, P.

    2009-12-01

    L-band synthetic aperture radar (SAR) images on Kilauea volcano have been archived by Japanese JERS-1 (1992-1998) and ALOS (2006-) satellites. L-band interferometric SAR (InSAR) can measure displacements in a broader region compared to C-band, thanks to higher phase coherence on vegetated areas. We made InSAR analyses on Kilauea using the following L-band data sets: J1) two JERS-1 images, acquired on 20 Oct. 1992 and 1 Mar. 1993 from a descending orbit (RSP path 589) with off-nadir angle of 34.3 degrees, J2) three JERS-1 images, acquired between 8 Oct. 1993 and 3 Jul. 1997 from a descending orbit (RSP path 590) with off-nadir angle of 34.3 degrees, A1) 13 ALOS images, acquired between 24 Jun. 2006 and 14 Feb. 2009 from an ascending orbit with off-nadir angle 9.9 degrees, and A2) 11 ALOS images, acquired between 21 May 2006 and 26 Feb. 2009 from a descending orbit with off-nadir angle 9.9 degrees. One-second SRTM digital elevation data were used to remove the topographic phase. The interferogram of the data set J1 contains signals of 1) a maximum of about 30 cm of range decrease resulting from a dike intrusion in the Makaopuhi crater area, 2) about 10 cm of maximum range increase in the Pu`u `O`o crater area, and 3) a few cm of range increase along the East Rift Zone (ERZ) between the summit and Pu`u `O`o craters. An interferogram (8 Oct. 1993 - 3 Jul. 1997) of the data set J2 indicates 1) range increase (maximum 7 cm/yr) in both the summit and Pu`u `O`o areas, 2) range increase (maximum 5 cm/yr) along the ERZ between the summit and Makaopuhi crater, and 3) range decrease (maximum 6cm/yr) on the southern flank near the coast that is consistent with a seaward movement of the southern flank. A small baseline subset InSAR time-series analysis was performed using all the images of the data sets A1 and A2, assuming that the data acquisitions had been made in pure vertical direction. The analysis period includes the 2007 Father's day dike intrusion. A preliminary result indicates the followings. Pre-eruption period (9 months): 12 cm/yr of uplift in an area of a few km SW of the summit caldera and 3 cm/yr of subsidence along the ERZ between the summit and Napau craters. Co-eruption period (7 months): 15 cm of subsidence in the summit crater and a few tens of cm of uplift associated with the diking. Post-eruption period (17 months): more than 2 cm/yr of subsidence in the summit area and at least 1 cm/yr of subsidence in the Pu`u `O`o area, where the spatial extensions of the two subsiding areas are comparable. While the obtained subsidence signals can be attributed to lava compactions and to artifacts due to errors in the digital elevation model, our results may indicate a developed shallow magma reservoir under the Pu`u `O`o crater, and also smaller shallow reservoirs distributed along the ERZ between the summit and Pu`u `O`o.

  18. Influence of Soil Tillage Systems on Soil Respiration and Production on Wheat, Maize and Soybean Crop

    NASA Astrophysics Data System (ADS)

    Moraru, P. I.; Rusu, T.

    2012-04-01

    Soil respiration leads to CO2 emissions from soil to the atmosphere, in significant amounts for the global carbon cycle. Soil capacity to produce CO2 varies depending on soil, season, intensity and quality of agrotechnical tillage, soil water, cultivated plant, fertilizer etc. The data presented in this paper were obtained on argic-stagnic Faeoziom (SRTS, 2003). These areas were was our research, presents a medium multiannual temperature of 8.20C, medium of multiannual rain drowns: 613 mm. The experimental variants chosen were: A. Conventional system (CS): V1-reversible plough (22-25 cm)+rotary grape (8-10 cm); B. Minimum tillage system (MT): V2 - paraplow (18-22 cm) + rotary grape (8-10 cm); V3 - chisel (18-22 cm) + rotary grape (8-10 cm);V4 - rotary grape (10-12 cm); C. No-Tillage systems (NT): V5 - direct sowing. The experimental design was a split-plot design with three replications. In one variant the area of a plot was 300 m2. The experimental variants were studied in the 3 years crop rotation: maize - soy-bean - autumn wheat. To soil respiration under different tillage practices, determinations were made for each crop in four vegetative stages (spring, 5-6 leaves, bean forming, harvest) using ACE Automated Soil CO2 Exchange System. Soil respiration varies throughout the year for all three crops of rotation, with a maximum in late spring (1383 to 2480 mmoli m-2s-1) and another in fall (2141 to 2350 mmoli m-2s-1). The determinations confirm the effect of soil tillage system on soil respiration, the daily average is lower at NT (315-1914 mmoli m-2s-1), followed by MT (318-2395 mmoli m-2s-1) and is higher in the CS (321-2480 mmol m-2s-1). Productions obtained at MT and NT don't have significant differences at wheat and are higher at soybean. The differences in crop yields are recorded at maize and can be a direct consequence of loosening, mineralization and intensive mobilization of soil fertility. Acknowledgments: This work was supported by CNCSIS-UEFISCSU, project number PN II-RU 273/2010.

  19. Survey Of CO{sub 2} Laser Ablation Propulsion With Polyoxymethylene Propellant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinko, John E.; Sasoh, Akihiro

    Polyoxymethylene (POM) has been widely studied as a laser propulsion propellant paired to CO{sub 2} laser radiation. POM is a good test case for studying ablation properties of polymer materials, and within limits, for study of general trends in laser ablation-induced impulse. Despite many studies, there is no general understanding of POM ablation that takes into account the ambient pressure, spot area, fluence, and effects from confinement and combustion. This paper reviews and synthesizes CO{sub 2} laser ablation propulsion research using POM targets. Necessary directions for future study are indicated to address incomplete regions of the various parameter spaces. Literaturemore » data is compared in terms of propulsion parameters such as momentum coupling coefficient and specific impulse, within a range of fluences from about 1-500 J/cm{sup 2}, ambient pressures from about 10{sup -2}-10{sup 5} Pa, and laser spot areas from about 0.01-10 cm{sup 2}.« less

  20. The influence of vegetation cover and soil physical properties on deflagration of shallow landslides - Nova Friburgo, RJ / Brazil

    NASA Astrophysics Data System (ADS)

    de Oliveira Marques, Maria Clara; Silva, Roberta; Fraga, Joana; Luiza Coelho Netto, Ana; Mululo Sato, Anderson

    2017-04-01

    In 2011, the mountainous region of the State of Rio de Janeiro (Brazil) suffered enormous social and economic losses due to thousands of landslides caused by an extreme rainfall event. The mapping of the scars of these landslides in an area of 421 km2 in the municipality of Nova Friburgo, RJ - Brazil resulted in a total of 3622, and 89% of these scars were located in areas covered by grasses and forests. Despite the unexpected result (64% of scars in forest areas), field evidence has shown that most of the forest fragments in the municipality are in the initial stages of succession and in different states of degradation, evidencing the need for a better understanding of the role of these forests in the detonation and propagation of landslides. Two slope forest areas with different ages (20 and 50 years) were evaluated in relation to the vegetative aspects that influence the stability of the slopes in each area. Hydrological monitoring, including precipitation, interception by manual and automatic method, soil moisture and subsurface flows were performed in two different areas: forest and grass. Soil moisture was monitored by granular matrix sensors and flows by collecting troughs in trenches at depths of 0 cm, 20 cm, 50 cm, 100 cm, 150 cm and 220 cm, which were also analyzed for biomass and length of thick roots (> 2 mm diameter) and thin roots (< 2 mm diameter) and for the soil physical properties (particle size, aggregate stability, porosity and hydraulic conductivity in situ). In the grass area, the lower soil structure in relation to the forest areas makes it difficult to transmit the water through the soil matrix. During the monitoring period, that area preserved the moisture in depths of 100 cm, 150 cm and 220 cm. The fasciculate root system of the grasses increased the infiltration of water at the top of the soil, favouring the formation of more superficial saturation zones in the heavy rains, due to the hydraulic discontinuities. In forest areas, infiltration by preferential paths allows the concentration of water in the depths in which they are terminal increasing the pore water pressure. Soil saturation in this area also occurred in heavy rains, but more deeply due to the rapid movement and redirection of water in depth by tree roots. This process was also responsible for the higher subsurface flows found in the forest, that is, the greater aggregation of the soil, the existence of interconnected macropores, ducts and roots facilitate the transmission of water in depth. Associated with the high rainfall and high relative humidity, these vegetation favoured the formation of saturation zones and increased pore pressures of the water, causing landslides on lands between 0.5 m and 2.0 m. The results of hydraulic conductivity show that the difference (lateritic = 10-4 cm/s; saprolitic = 10-5 cm/s) between the layers of the soil can generate zones of hydraulic discontinuity in extreme rainfall events, which would justify the predominance of shallow translational landslides at these same depths.

  1. Galvanic corrosion behaviors of Cu connected to Au on a printed circuit board in ammonia solution

    NASA Astrophysics Data System (ADS)

    Oh, SeKwon; Kim, YoungJun; Jung, KiMin; Park, MiSeok; Shon, MinYoung; Kwon, HyukSang

    2018-01-01

    During etching treatments of printed circuit board (PCB) with ammnioa solution, galvanic corrosion occurs between electrically connected gold and copper, and resulting in unexpected over-etching problems. Herein, we determine corrosion of galvanic coupled Cu to Au quantitatively in ammonia solutions, and evaluate factors influencing corrosion of galvanic coupled Cu to Au (i.e., area ratio of anode to cathode and stirring speed). The difference of the corrosion rate (Δi = icouple, (Cu-Au)-icorr, Cu) of Cu connected to Au (117 μA/cm2) and of single Cu (86 μA/cm2) infers the amount of over-etching of Cu resulting from galvanic corrosion in ammonia solution (Δi = 0.31 μA/cm2). As the stirring speed increases from 0 to 400 rpm, the corrosion rate of galvanic coupled Cu to Au increases from 36 to 191 μA/cm2. Furthermore, we confirm that an increase in the area ratio (Au/Cu) from 0.5 to 25 results in a higher rate of corrosion of Cu connected to Au. The corrosion rate of galvanic coupled Cu to Au is approximately 20 times higher when the area ratio of Au to Cu is 25 (1360 μA/cm2) than when the ratio is 0.5 (67 μA/cm2).

  2. Are the surgeons safe during UV-A radiation exposure in collagen cross-linking procedure?

    PubMed

    Shetty, Rashmi; Shetty, Rohit; Mahendradas, Padmamalini; Shetty, Bhujang K

    2012-02-01

    To quantify the effect of scattered UV-A radiation used in the collagen cross-linking (CXL) procedure and the amount of radiation reaching the surgeon and the surrounding area and to estimate the dampening effect by various protective devices. In this case series, 3 patients [aged 25-30 (±2.5) years] with keratoconus underwent a CXL procedure with UV-A light and riboflavin. Irradiance was measured using a spectrometer (Model USB2000; Ocean Optics, Inc) for various distances from the source, at various angles, and for different durations of radiation. The spectrometer was also used to measure the dampening effect produced by gown, latex gloves, and UV-protective glasses. Maximum UV-A radiation (1.4 × 10(-9) mW/cm(2)) was measured at 2 cm from the limbus, when the probe was held at a 45-degree angle to the floor. UV-A radiation reaching the surgeon's eye and the abdomen was 3.403 × 10(-11) and 2.36 × 10(-11) mW/cm(2), respectively. Gown, latex gloves, and UV-protective glasses showed dampening effects of 99.58%, 95.01%, and 99.73%, respectively. CXL appears to be a safe procedure with respect to UV-A radiation exposure to the surgeon. Further safety can be ensured by UV-protective devices.

  3. Silicon oxycarbide glass-graphene composite paper electrode for long-cycle lithium-ion batteries.

    PubMed

    David, Lamuel; Bhandavat, Romil; Barrera, Uriel; Singh, Gurpreet

    2016-03-30

    Silicon and graphene are promising anode materials for lithium-ion batteries because of their high theoretical capacity; however, low volumetric energy density, poor efficiency and instability in high loading electrodes limit their practical application. Here we report a large area (approximately 15 cm × 2.5 cm) self-standing anode material consisting of molecular precursor-derived silicon oxycarbide glass particles embedded in a chemically-modified reduced graphene oxide matrix. The porous reduced graphene oxide matrix serves as an effective electron conductor and current collector with a stable mechanical structure, and the amorphous silicon oxycarbide particles cycle lithium-ions with high Coulombic efficiency. The paper electrode (mass loading of 2 mg cm(-2)) delivers a charge capacity of ∼588 mAh g(-1)electrode (∼393 mAh cm(-3)electrode) at 1,020th cycle and shows no evidence of mechanical failure. Elimination of inactive ingredients such as metal current collector and polymeric binder reduces the total electrode weight and may provide the means to produce efficient lightweight batteries.

  4. High-intensity Interval Training Frequency: Cardiometabolic Effects and Quality of Life.

    PubMed

    Stavrinou, Pinelopi S; Bogdanis, Gregory C; Giannaki, Christoforos D; Terzis, Gerasimos; Hadjicharalambous, Marios

    2018-02-01

    The effects of high intensity interval training (HIIT) frequency on cardiometabolic health and quality of life were examined in 35 healthy inactive adults (age: 31.7±2.6 yrs, VO 2 peak: 32.7±7.4 ml·: kg -1 ·: min -1 ). Participants were randomly assigned to a control (CON) and two training groups, which performed 10×60-s cycling at ~83% of peak power, two (HIIT-2) or three times per week (HIIT-3) for eight weeks. Compared with CON, both training regimes resulted in similar improvements in VO 2 peak (HIIT-2: 10.8%, p=0.048, HIIT-3: 13.6%, p=0.017), waist circumference (HIIT-2: -1.4 cm, p=0.048, HIIT-3: -2.4 cm, p=0.028), thigh cross-sectional area (HIIT-2: 11.4 cm 2 , p=0.001, HIIT-3: 9.3 cm 2 , p=0.001) and the physical health component of quality of life (HIIT-2: 8.4, p=0.001, HIIT-3: 12.2, p=0.001). However, HIIT-3 conferred additional health-related benefits by reducing total body and trunk fat percentage (p<0.05, compared with CON), total cholesterol and low-density lipoprotein-cholesterol (p<0.02, compared with CON) and by improving the mental component of quality of life (p=0.045, compared with CON). In conclusion, performing HIIT only twice per week is effective in promoting cardiometabolic health-related adaptations and quality of life in inactive adults. However, higher HIIT frequency is required for an effect on fat deposits, cholesterol and mental component of well-being. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Evaluation of wound healing in diabetic foot ulcer using platelet-rich plasma gel: A single-arm clinical trial.

    PubMed

    Mohammadi, Mohammad Hossein; Molavi, Behnam; Mohammadi, Saeed; Nikbakht, Mohsen; Mohammadi, Ashraf Malek; Mostafaei, Shayan; Norooznezhad, Amir Hossein; Ghorbani Abdegah, Ali; Ghavamzadeh, Ardeshir

    2017-04-01

    The aim of the present study was to evaluate the effectiveness of using autologous platelet-rich plasma (PRP) gel for treatment of diabetic foot ulcer (DFU) during the first 4 weeks of the treatment. In this longitudinal and single-arm trial, 100 patients were randomly selected after meeting certain inclusion and exclusion criteria; of these 100 patients, 70 (70%) were enrolled in the trial. After the primary care actions such as wound debridement, the area of each wound was calculated and recorded. The PRP therapy (2mL/cm 2 of ulcers) was performed weekly until the healing time for each patient. We used one sample T-test for healing wounds and Bootstrap resampling approach for reporting confidence interval with 1000 Bootstrap samples. The p-value<0.05 were considered statistically significant. The mean (SD) of DFU duration was 19.71 weeks (4.94) for units sampling. The ratio of subjects who withdrew from the study was calculated to be 2 (2.8%). Average area of 71 ulcers in the mentioned number of cases was calculated to be 6.11cm 2 (SD: 4.37). Also, the mean, median (SD) of healing time was 8.7, 8 weeks (SD: 3.93) except for 2 mentioned cases. According to one sample T-test, wound area (cm 2 ), on average, significantly decreased to 51.9% (CI: 46.7-57.1) through the first four weeks of therapy. Furthermore, significant correlation (0.22) was not found between area of ulcers and healing duration (p-value>0.5). According to the results, PRP could be considered as a candidate treatment for non-healing DFUs as it may prevent future complications such as amputation or death in this pathological phenomenon. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Effect of load alterations on the effective regurgitant orifice area in chronic aortic regurgitation.

    PubMed

    Kim, Y J; Jones, M; Shiota, T; Tsujino, H; Qin, J X; Bauer, F; Sitges, M; Kwan, J; Cardon, L A; Zetts, A D; Thomas, J D

    2002-10-01

    To evaluate the load dependence of effective regurgitant orifice area (ROA) in an animal model of chronic aortic regurgitation. Eight sheep were studied 10-20 weeks after the surgical creation of aortic regurgitation. After baseline studies, 500 ml of blood, angiotensin II, and nitroprusside were infused sequentially. Electromagnetic flow meters were used as reference standards to determine aortic regurgitation volume. The time-velocity integral was acquired using the continuous wave Doppler method. Baseline aortic regurgitant volume varied from 8 ml (regurgitant fraction 28%) to 29 ml (59%), with a mean (SD) value of 17 (8) ml; mean ROA was 0.15 (0.05) cm2. During angiotensin II infusion, aortic regurgitation volume (20 (8) ml) and mean diastolic aortoventricular pressure gradient (62 (18) mm Hg) increased by 26 (16)% and 48 (64)%, respectively (p < 0.01 for both). ROA did not change (0.16 (0.06) cm(2), p = 0.15). During nitroprusside infusion, aortic regurgitant volume (13 (7) ml, p = 0.05) and diastolic pressure gradient (25 (13) mm Hg, p < 0.05) decreased. ROA did not change (0.15 (0.05) cm2). When analysing 32 stages together, aortic regurgitant volume (r = 0.78, p < 0.01) and regurgitant fraction (r = 0.55, p < 0.01) correlated well with ROA. However, diastolic pressure gradient (r = 0.28) was not significantly correlated with ROA. In an animal model of chronic aortic regurgitation, ROA did not change with load alterations.

  7. Comparable Effects of High-Intensity Interval Training and Prolonged Continuous Exercise Training on Abdominal Visceral Fat Reduction in Obese Young Women

    PubMed Central

    Zhang, Haifeng; Tong, Tom K.; Qiu, Weifeng; Zhang, Xu; Zhou, Shi

    2017-01-01

    This study compared the effect of prolonged moderate-intensity continuous training (MICT) on reducing abdominal visceral fat in obese young women with that of work-equivalent (300 kJ/training session) high-intensity interval training (HIIT). Forty-three participants received either HIIT (n = 15), MICT (n = 15), or no training (CON, n = 13) for 12 weeks. The abdominal visceral fat area (AVFA) and abdominal subcutaneous fat area (ASFA) of the participants were measured through computed tomography scans preintervention and postintervention. Total fat mass and the fat mass of the android, gynoid, and trunk regions were assessed through dual-energy X-ray absorptiometry. Following HIIT and MICT, comparable reductions in AVFA (−9.1, −9.2 cm2), ASFA (−35, −28.3 cm2), and combined AVFA and ASFA (−44.7, −37.5 cm2, p > 0.05) were observed. Similarly, reductions in fat percentage (−2.5%, −2.4%), total fat mass (−2.8, −2.8 kg), and fat mass of the android (−0.3, −0.3 kg), gynoid (−0.5, −0.7 kg), and trunk (−1.6, −1.2 kg, p > 0.05) regions did not differ between HIIT and MICT. No variable changed in CON. In conclusion, MICT consisting of prolonged sessions has no quantitative advantage, compared with that resulting from HIIT, in abdominal visceral fat reduction. HIIT appears to be the predominant strategy for controlling obesity because of its time efficiency. PMID:28116314

  8. Transistors and tunnel diodes enabled by large-scale MoS2 nanosheets grown on GaN

    NASA Astrophysics Data System (ADS)

    San Yip, Pak; Zou, Xinbo; Cho, Wai Ching; Wu, Kam Lam; Lau, Kei May

    2017-07-01

    We report growth, fabrication, and device results of MoS2-based transistors and diodes implemented on a single 2D/3D material platform. The 2D/3D platform consists of a large-area MoS2 thin film grown on SiO2/p-GaN substrates. Atomic force microscopy, scanning electron microscopy, and Raman spectroscopy were used to characterize the thickness and quality of the as-grown MoS2 film, showing that the large-area MoS2 nanosheet has a smooth surface morphology constituted by small grains. Starting from the same material, both top-gated MoS2 field effect transistors and MoS2/SiO2/p-GaN heterojunction diodes were fabricated. The transistors exhibited a high on/off ratio of 105, a subthreshold swing of 74 mV dec-1, field effect mobility of 0.17 cm2 V-1 s-1, and distinctive current saturation characteristics. For the heterojunction diodes, current-rectifying characteristics were demonstrated with on-state current density of 29 A cm-2 and a current blocking property up to -25 V without breakdown. The reported transistors and diodes enabled by the same 2D/3D material stack present promising building blocks for constructing future nanoscale electronics.

  9. Transport of atrazine and dicamba through silt and loam soils

    USGS Publications Warehouse

    Tindall, James A.; Friedel, Michael J.

    2016-01-01

    The objectives of this research were to determine the role of preferential flow paths in the transport of atrazine (2-chloro-4-(ethylamino)-6-(isopropylamino)-s-triazine) and dicamba (3-6-dichloro-2-methoxybenzoic acid) through silt and loam soils overlying the High Plains aquifer in Nebraska. In a previous study, 3 of 6 study areas demonstrated high percentages of macropores; those three areas were used in this study for analysis of chemical transport. As a subsequent part of the study, 12 intact soil cores (30-cm diameter by 40-cm height), were excavated sequentially, two from each of the following depths: 0-40cm and 40-80cm. These cores were used to study preferential flow characteristics using dye staining and to determine hydraulic properties. Two undisturbed experimental field plots, each with a 3-m2 surface area, were installed in three study areas in Nebraska. Each was instrumented with suction lysimeters and tensiometers at depths of 10cm to 80cm in 10-cm increments. Additionally, each plot was planted with corn (Zea mays). A neutron probe access tube was installed in each plot to determine soil w ater content at 15-cm intervals. All plots were enclosed w ith a raised frame (of 8-cm height) to prevent surface runoff. All suction lysimeters were purged monthly for three months and were sampled immediately prior to pre-plant herbicide application to obtain background chemical concentrations. Atrazine and dicamba moved rapidly through the soil, but only after a heavy rainfall event, probably owing to the presence of preferential flow paths and lack of microbial degradation in these soil areas. Staining of laboratory cores showed a positive correlation between the percent area stained by depth and the subsequent breakthrough of Br- in the laboratory and leaching of field-applied herbicides owing to large rainfall events. Suction lysimeter samples in the field showed increases in concentrations of herbicides at depths where laboratory data indicated greater percentages of what appeared to be preferential flow paths. Concentrations of atrazine and dicamba exceeding 0.30 and 0.05µg m1-1 were observed at depths of 10-30cm and 50-70cm after two months following heavy rainfall events. It appears from the laboratory experiment that preferential flow paths were a significant factor in transport of atrazine and dicamba.

  10. The effect of cathode felt geometries on electrochemical characteristics of sodium sulfur (NaS) cells: Planar vs. tubular

    NASA Astrophysics Data System (ADS)

    Kim, Goun; Park, Yoon-Cheol; Lee, Younki; Cho, Namung; Kim, Chang-Soo; Jung, Keeyoung

    2016-09-01

    Two sodium sulfur (NaS) cells, one with a planar design and the other with a tubular design, were subject to discharge-charge cycles in order to investigate the effect of cathode felt geometries on electrochemical characteristics of NaS cells. Their discharge-charge behaviors over 200 cycles were evaluated at the operation temperature of 350 °C with the current densities of 100 mA cm-2 for discharge and 80 mA cm-2 for charge. The results showed that the deviation from theoretical open circuit voltage changes of a planar cell was smaller than those of a tubular cell resulting in potential specific power loss reduction during operation. In order to understand the effect, a three dimensional statistically representative matrix for a cathode felt has been generated using experimentally measured data. It turns out that the area specific fiber number density in the outer side area of a tubular cathode felt is smaller than that of a planar felt resulting in occurrence of larger voltage drops via retarded convection of cathode melts during cell operation.

  11. The fabrication of ZnO nanowire field-effect transistors by roll-transfer printing

    NASA Astrophysics Data System (ADS)

    Chang, Yi-Kuei; Hong, Franklin Chau-Nan

    2009-05-01

    A method with the potential to fabricate large-area nanowire field-effect transistors (NW-FETs) was demonstrated in this study. Using a high-speed roller (20-80 cm min-1), transfer printing was successfully employed to transfer vertically aligned zinc oxide (ZnO) nanowires grown on a donor substrate to a polydimethylsiloxane (PDMS) stamp and then print the ordered ZnO nanowire arrays on the received substrate for the fabrication of NW-FETs. ZnO NW-FETs fabricated by this method exhibit high performances with a threshold voltage of around 0.25 V, a current on/off ratio as high as 105, a subthreshold slope of 360 mV/dec, and a field-effect mobility of around 90 cm2 V-1 s-1. The excellent device characteristics suggest that the roll-transfer printing technique, which is compatible with the roll-to-roll (R2R) process and operated in atmosphere, has a good potential for the high-speed fabrication of large-area nanowire transistors for flexible devices and flat panel displays.

  12. The fabrication of ZnO nanowire field-effect transistors by roll-transfer printing.

    PubMed

    Chang, Yi-Kuei; Hong, Franklin Chau-Nan

    2009-05-13

    A method with the potential to fabricate large-area nanowire field-effect transistors (NW-FETs) was demonstrated in this study. Using a high-speed roller (20-80 cm min(-1)), transfer printing was successfully employed to transfer vertically aligned zinc oxide (ZnO) nanowires grown on a donor substrate to a polydimethylsiloxane (PDMS) stamp and then print the ordered ZnO nanowire arrays on the received substrate for the fabrication of NW-FETs. ZnO NW-FETs fabricated by this method exhibit high performances with a threshold voltage of around 0.25 V, a current on/off ratio as high as 10(5), a subthreshold slope of 360 mV/dec, and a field-effect mobility of around 90 cm(2) V(-1) s(-1). The excellent device characteristics suggest that the roll-transfer printing technique, which is compatible with the roll-to-roll (R2R) process and operated in atmosphere, has a good potential for the high-speed fabrication of large-area nanowire transistors for flexible devices and flat panel displays.

  13. Application of large area SiPMs for the readout of a plastic scintillator based timing detector

    NASA Astrophysics Data System (ADS)

    Betancourt, C.; Blondel, A.; Brundler, R.; Dätwyler, A.; Favre, Y.; Gascon, D.; Gomez, S.; Korzenev, A.; Mermod, P.; Noah, E.; Serra, N.; Sgalaberna, D.; Storaci, B.

    2017-11-01

    In this study an array of eight 6 mm × 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm × 6 cm × 1 cm and 120 cm × 11 cm × 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided in light of the results.

  14. High-Temperature-Short-Time Annealing Process for High-Performance Large-Area Perovskite Solar Cells.

    PubMed

    Kim, Minjin; Kim, Gi-Hwan; Oh, Kyoung Suk; Jo, Yimhyun; Yoon, Hyun; Kim, Ka-Hyun; Lee, Heon; Kim, Jin Young; Kim, Dong Suk

    2017-06-27

    Organic-inorganic hybrid metal halide perovskite solar cells (PSCs) are attracting tremendous research interest due to their high solar-to-electric power conversion efficiency with a high possibility of cost-effective fabrication and certified power conversion efficiency now exceeding 22%. Although many effective methods for their application have been developed over the past decade, their practical transition to large-size devices has been restricted by difficulties in achieving high performance. Here we report on the development of a simple and cost-effective production method with high-temperature and short-time annealing processing to obtain uniform, smooth, and large-size grain domains of perovskite films over large areas. With high-temperature short-time annealing at 400 °C for 4 s, the perovskite film with an average domain size of 1 μm was obtained, which resulted in fast solvent evaporation. Solar cells fabricated using this processing technique had a maximum power conversion efficiency exceeding 20% over a 0.1 cm 2 active area and 18% over a 1 cm 2 active area. We believe our approach will enable the realization of highly efficient large-area PCSs for practical development with a very simple and short-time procedure. This simple method should lead the field toward the fabrication of uniform large-scale perovskite films, which are necessary for the production of high-efficiency solar cells that may also be applicable to several other material systems for more widespread practical deployment.

  15. Rehabilitating gravel areas with short-hair sedge sod plugs and fertilizer

    Treesearch

    Raymond D. Ratliff

    1985-01-01

    Tests to rehabilitate gravel areas in high value recreation sites were carried out by transplanting short-hair sedge (Carex exserta) plugs. The plugs were 1.9 cm (0.75 inch) and 5.1 cm (2.0 inches) in diameter, 10 cm (4.0 inches) deep, and were transplanted in September 1981, with and without papier-mache pots. The test site was Siberian Outpost, in...

  16. Large Area, High Reliability Liquid Dielectric Systems: Provisional Design Criteria and Experimental Approaches to More Realistic Projections

    DTIC Science & Technology

    2001-06-01

    illustrated in Fig. 1, where the regions of highly-stressed electrodes in the water and oil are indicated. There will be of the order first tests...will be on oil. We will be able to test only ∧ 104 cm2 of electrode compared with ~108 cm2 in the power plant, and even if we are able to accelerate...the data in Ref. 3 further illustrates this question and how it might be tested. For a 100 cm2 electrode area in water, the stress cor- responding to

  17. Experimental study of CO/sub 2/-laser-induced histological effects on human fallopian tube: determination of CO/sub 2/ laser parameters to be used in microsurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foulot, H.; Lefebvre, G.; Jagueux, M.

    This experiment investigates CO/sub 2/-laser-induced histological effects on fallopian tubes obtained during hysterectomies in women. Tubal transversal sections were performed at isthmic and ampullar sites. Forty strips were available for histological study of the cut section area. The role of different parameters such as radiation power and beam fractionation (continuous versus pulsed) on tissue lesions was assessed. In tubal microsurgery, the CO/sub 2/ laser can be used as a scalpel with the predominant advantage of minimal tissular alterations. As a result of this study, our recommended parameters are the following: radiation power, 7-10 W; beam focalization zone, 0.2 mm; energymore » density, 20,000-35,000 W/cm2; continuous operation; moving speed, 1 cm/s.« less

  18. Morphological changes produced by acid dissolution in Er:YAG laser irradiated dental enamel.

    PubMed

    Manuela Díaz-Monroy, Jennifer; Contreras-Bulnes, Rosalía; Fernando Olea-Mejía, Oscar; Emma Rodríguez-Vilchis, Laura; Sanchez-Flores, Ignacio

    2014-06-01

    Several scientific reports have shown the effects of Er:YAG laser irradiation on enamel morphology. However, there is lack of information regarding the morphological alterations produced by the acid attack on the irradiated surfaces. The aim of this study was to evaluate the morphological changes produced by acid dissolution in Er:YAG laser irradiated dental enamel. Forty-eight enamel samples were divided into four groups (n = 12). GI (control); Groups II, III, and IV were irradiated with Er:YAG at 100 mJ (12.7 J/cm(2) ), 200 mJ (25.5 J/cm(2) ), and 300 mJ (38.2 J/cm(2) ), respectively, at 10 Hz without water irrigation. Enamel morphology was evaluated before-irradiation, after-irradiation, and after-acid dissolution, by scanning electron microscopy (SEM). Sample coating was avoided and SEM analysis was performed in a low-vacuum mode. To facilitate the location of the assessment area, a reference point was marked. Morphological changes produced by acid dissolution of irradiated enamel were observed, specifically on laser-induced undesired effects. These morphological changes were from mild to severe, depending on the presence of after-irradiation undesired effects. © 2014 Wiley Periodicals, Inc.

  19. Evaluation of the performance of small diode pumped UV solid state (DPSS) Nd:YAG lasers as new radiation sources for atmospheric pressure laser ionization mass spectrometry (APLI-MS).

    PubMed

    Kersten, Hendrik; Lorenz, Matthias; Brockmann, Klaus J; Benter, Thorsten

    2011-06-01

    The performance of a KrF* bench top excimer laser and a compact diode pumped UV solid state (DPSS) Nd:YAG laser as photo-ionizing source in LC-APLI MS is compared. The commonly applied bench-top excimer laser, operating at 248 nm, provides power densities of the order of low MW/cm(2) on an illuminated area of 0.5 cm(2) (8 mJ/pulse, 5 ns pulse duration, beam waist area 0.5 cm(2), 3 MW/cm(2)). The DPSS laser, operating at 266 nm, provides higher power densities, however, on a two orders of magnitude smaller illuminated area (60 μJ/pulse, 1 ns pulse duration, beam waist area 2 × 10(-3) cm(2), 30 MW/cm(2)). In a common LC-APLI MS setup with direct infusion of a 10 nM pyrene solution, the DPSS laser yields a significantly smaller ion signal (0.9%) and signal to noise ratio (1.4%) compared with the excimer laser. With respect to the determined low detection limits (LODs) for PAHs of 0.1 fmol using an excimer laser, LODs in DPSS laser LC-APLI MS in the low pmol regime are expected. The advantages of the DPSS laser with respect to applicability (size, cost, simplicity) may render this light source the preferred one for APLI applications not focusing on ultimately high sensitivities. Furthermore, the impact of adjustable ion source parameters on the performance of both laser systems is discussed in terms of the spatial sensitivity distribution described by the distribution of ion acceptance (DIA) measurements. Perspectives concerning the impact on future APLI-MS applications are given.

  20. Characterization of HgCdTe Films Grown on Large-Area CdZnTe Substrates by Molecular Beam Epitaxy

    NASA Astrophysics Data System (ADS)

    Arkun, F. Erdem; Edwall, Dennis D.; Ellsworth, Jon; Douglas, Sheri; Zandian, Majid; Carmody, Michael

    2017-09-01

    Recent advances in growth of Hg1- x Cd x Te films on large-area (7 cm × 7.5 cm) CdZnTe (CZT) substrates is presented. Growth of Hg1- x Cd x Te with good uniformity on large-area wafers is achieved using a Riber 412 molecular beam epitaxy (MBE) tool designed for growth of Hg1- x Cd x Te compounds. The reactor is equipped with conventional CdTe, Te, and Hg sources for achieving uniform exposure of the wafer during growth. The composition of the Hg1- x Cd x Te compound is controlled in situ by employing a closed-loop spectral ellipsometry technique to achieve a cutoff wavelength ( λ co) of 14 μm at 78 K. We present data on the thickness and composition uniformity of films grown for large-format focal-plane array applications. The composition and thickness nonuniformity are determined to be <1% over the area of a 7 cm × 7.5 cm wafer. The films are further characterized by Fourier-transform infrared spectroscopy, optical microscopy, and Hall measurements. Additionally, defect maps show the spatial distribution of defects generated during the epitaxial growth of the Hg1- x Cd x Te films. Microdefect densities are in the low 103 cm-2 range, and void defects are below 500 cm-2. Dislocation densities less than 5 × 105 cm-2 are routinely achieved for Hg1- x Cd x Te films grown on CZT substrates. HgCdTe 4k × 4k focal-plane arrays with 15 μm pitch for astronomical wide-area infrared imagers have been produced using the recently developed MBE growth process at Teledyne Imaging Sensors.

  1. A cost-effective nanoporous ultrathin film electrode based on nanoporous gold/IrO2 composite for proton exchange membrane water electrolysis

    NASA Astrophysics Data System (ADS)

    Zeng, Yachao; Guo, Xiaoqian; Shao, Zhigang; Yu, Hongmei; Song, Wei; Wang, Zhiqiang; Zhang, Hongjie; Yi, Baolian

    2017-02-01

    A cost-effective nanoporous ultrathin film (NPUF) electrode based on nanoporous gold (NPG)/IrO2 composite has been constructed for proton exchange membrane (PEM) water electrolysis. The electrode was fabricated by integrating IrO2 nanoparticles into NPG through a facile dealloying and thermal decomposition method. The NPUF electrode is featured in its 3D interconnected nanoporosity and ultrathin thickness. The nanoporous ultrathin architecture is binder-free and beneficial for improving electrochemical active surface area, enhancing mass transport and facilitating releasing of oxygen produced during water electrolysis. Serving as anode, a single cell performance of 1.728 V (@ 2 A cm-2) has been achieved by NPUF electrode with a loading of IrO2 and Au at 86.43 and 100.0 μg cm-2 respectively, the electrolysis voltage is 58 mV lower than that of conventional electrode with an Ir loading an order of magnitude higher. The electrolysis voltage kept relatively constant up to 300 h (@250 mA cm-2) during the course of durability test, manifesting that NPUF electrode is promising for gas evolution.

  2. The influence of water resistance therapy on vocal fold vibration: a high-speed digital imaging study.

    PubMed

    Guzman, Marco; Laukkanen, Anne-Maria; Traser, Louisa; Geneid, Ahmed; Richter, Bernhard; Muñoz, Daniel; Echternach, Matthias

    2017-10-01

    This study investigated the influence of tube phonation into water on vocal fold vibration. Eight participants were analyzed via high-speed digital imaging while phonating into a silicon tube with the free end submerged into water. Two test sequences were studied: (1) phonation pre, during, and post tube submerged 5 cm into water; and (2) phonation into tube submerged 5 cm, 10 cm, and 18 cm into water. Several glottal area parameters were calculated using phonovibrograms. The results showed individual differences. However, certain trends were possible to identify based on similar results found for the majority of participants. Amplitude-to-length ratio, harmonic-to-noise ratio, and spectral flatness (derived from glottal area) decreased for all tube immersion depths, while glottal closing quotient increased for 10 cm immersion and contact quotient for 18 cm immersion. Closed quotient decreased during phonation into the tube at 5 cm depth, and jitter decreased during and after it. Results suggest that the depth of tube submersion appears to have an effect on phonation. Shallow immersion seems to promote smoother and more stable phonation, while deeper immersion may involve increased respiratory and glottal effort to compensate for the increased supraglottal resistance. This disparity, which is dependent upon the degree of flow resistance, should be considered when choosing treatment exercises for patients with various diagnoses, namely hyperfunctional or hypofunctional dysphonia.

  3. Postural Instability Induced by Visual Motion Stimuli in Patients With Vestibular Migraine

    PubMed Central

    Lim, Yong-Hyun; Kim, Ji-Soo; Lee, Ho-Won; Kim, Sung-Hee

    2018-01-01

    Patients with vestibular migraine are susceptible to motion sickness. This study aimed to determine whether the severity of posture instability is related to the susceptibility to motion sickness. We used a visual motion paradigm with two conditions of the stimulated retinal field and the head posture to quantify postural stability while maintaining a static stance in 18 patients with vestibular migraine and in 13 age-matched healthy subjects. Three parameters of postural stability showed differences between VM patients and controls: RMS velocity (0.34 ± 0.02 cm/s vs. 0.28 ± 0.02 cm/s), RMS acceleration (8.94 ± 0.74 cm/s2 vs. 6.69 ± 0.87 cm/s2), and sway area (1.77 ± 0.22 cm2 vs. 1.04 ± 0.25 cm2). Patients with vestibular migraine showed marked postural instability of the head and neck when visual stimuli were presented in the retinal periphery. The pseudo-Coriolis effect induced by head roll tilt was not responsible for the main differences in postural instability between patients and controls. Patients with vestibular migraine showed a higher visual dependency and low stability of the postural control system when maintaining quiet standing, which may be related to susceptibility to motion sickness. PMID:29930534

  4. Postural Instability Induced by Visual Motion Stimuli in Patients With Vestibular Migraine.

    PubMed

    Lim, Yong-Hyun; Kim, Ji-Soo; Lee, Ho-Won; Kim, Sung-Hee

    2018-01-01

    Patients with vestibular migraine are susceptible to motion sickness. This study aimed to determine whether the severity of posture instability is related to the susceptibility to motion sickness. We used a visual motion paradigm with two conditions of the stimulated retinal field and the head posture to quantify postural stability while maintaining a static stance in 18 patients with vestibular migraine and in 13 age-matched healthy subjects. Three parameters of postural stability showed differences between VM patients and controls: RMS velocity (0.34 ± 0.02 cm/s vs. 0.28 ± 0.02 cm/s), RMS acceleration (8.94 ± 0.74 cm/s 2 vs. 6.69 ± 0.87 cm/s 2 ), and sway area (1.77 ± 0.22 cm 2 vs. 1.04 ± 0.25 cm 2 ). Patients with vestibular migraine showed marked postural instability of the head and neck when visual stimuli were presented in the retinal periphery. The pseudo-Coriolis effect induced by head roll tilt was not responsible for the main differences in postural instability between patients and controls. Patients with vestibular migraine showed a higher visual dependency and low stability of the postural control system when maintaining quiet standing, which may be related to susceptibility to motion sickness.

  5. Quantification of instantaneous flow rate and dynamically changing effective orifice area using a geometry independent three-dimensional digital color Doppler method: An in vitro study mimicking mitral regurgitation.

    PubMed

    Li, Xiaokui; Wanitkun, Suthep; Li, Xiang-Ning; Hashimoto, Ikuo; Mori, Yoshiki; Rusk, Rosemary A; Hicks, Shannon E; Sahn, David J

    2002-10-01

    Our study was intended to test the accuracy of a 3-dimensional (3D) digital color Doppler flow convergence (FC) method for assessing the effective orifice area (EOA) in a new dynamic orifice model mimicking a variety of mitral regurgitation. FC surface area methods for detecting EOA have been reported to be useful for quantifying the severity of valvular regurgitation. With our new 3D digital direct FC method, all raw velocity data are available and variable Nyquist limits can be selected for computation of direct FC surface area for computing instantaneous flow rate and temporal change of EOA. A 7.0-MHz multiplane transesophageal probe from an ultrasound system (ATL HDI 5000) was linked and controlled by a computer workstation to provide 3D images. Three differently shaped latex orifices (zigzag, arc, and straight slit, each with cutting-edge length of 1 cm) were used to mimic the dynamic orifice of mitral regurgitation. 3D FC surface computation was performed on parallel slices through the 3D data set at aliasing velocities (14-48 cm/s) selected to maximize the regularity and minimize lateral dropout of the visualized 3D FC at 5 points per cardiac cycle. Using continuous wave velocity for each, 3D-calculated EOA was compared with EOA determined by using continuous wave Doppler and the flow rate from a reference ultrasonic flow meter. Simultaneous digital video images were also recorded to define the actual orifice size for 9 stroke volumes (15-55 mL/beat with maximum flow rates 45-182 mL/s). Over the 9 pulsatile flow states and 3 orifices, 3D FC EOAs (0.05-0.63 cm(2)) from different phases of the cardiac cycle in each pump setting correlated well with reference EOA (r = 0.89-0.92, SEE = 0.027-0.055cm(2)) and they also correlated well with digital video images of the actual orifice peak (r = 0.97-0.98, SEE = 0.016-0.019 cm(2)), although they were consistently smaller, as expected by the contraction coefficient. The digital 3D FC method can accurately predict flow rate, and, thus, EOA (in conjunction with continuous wave Doppler), because it allows direct FC surface measurement despite temporal variability of FC shape.

  6. Model tests for the efficacy of disinfectants on surfaces. IV. Communication: dependence of test results on the amount of contamination and the kind of active substance.

    PubMed

    Peters, J; Spicher, G

    1998-12-01

    In the assessment of efficacy of surface disinfectants, many influencing factors have to be taken into account. One essential item is whether the surface to be disinfected is clean or soiled. Among the feasible soilings, the blood is of particular consequences because it ads impediments to many disinfecting agents. This paper shows to what extent the impairment of the efficacy of typical active agents depends on the blood burden of the surfaces. Therefore, test surfaces (varnished plywood) were contaminated with 0.01 to 0.08 ml of coagulating blood per test area (3 cm2). The blood contained cells of Staphylococcus aureus as test germs. The disinfection was effected by immersing the test objects in the disinfecting solution for 5 seconds and mingling the adhering disinfecting solution (about 0.02 ml) with the coagulated blood on the test surface with a glass spatula for about 20 seconds. Subsequently, the test objects remained in a horizontal position at room conditions for 4 hours and then the numbers of surviving test germs were determined. The graphical representation of the results shows that the efficacy curves of formaldehyde and phenol lie very closely together, i.e. their effect is hardly impaired by the different blood burdens of the test areas. The efficacy curves of glutaraldehyde, peracetic acid, chloramine T, and quaternary ammonium compounds lie very far apart from each other. To achieve the same microbicidal effect (log N/N0 = -5) when the contaminating amount is raised from 10 microliters/3 cm2 to 80 microliters/3 cm2, the concentration of chloramine T has to be raised by a factor of 5.4, peracetic acid by a factor of 9, glutaraldehyde by a factor of 24, quaternary ammonium compound even by a factor of 67. Ethanol and sodium hypochlorite showed a divergent behaviour. For ethanol, the efficacy diminution produced by increasing the contamination amount by a factor of 4 can be compensated by raising the concentration from 50% to about 70%. But again and again, there were test objects on which the number of germs able to reproduce had only been lowered by a factor of about 10(-3). At the highest contamination of 80 microliters/3 cm2, even 95% ethanol proved to be completely insufficient. With sodium hypochlorite even at the lowest contamination of 10 microliters/3 cm2, a microbicidal effect of only about 10(-5) was obtained. With increasing contamination, the highest achievable microbicidal effect clearly decreased. It is remarkable that the microbicidal effect of this active agent decreased with increasing concentrations. The results show how important it is in testing the efficacy of disinfecting agents to exactly lay down the amount of contaminating substances. To find out how safely an agent works under harder circumstances, the dependence of the microbicidal effect from the amount of contaminating substances per test area has to be determined.

  7. Sediment studies associated with drilling activity on a tropical shallow shelf.

    PubMed

    Souza, Claudete R; Vital, Helenice; Melo, Germano; Souza, Cleuneide R; da Silva Nogueira, Mary Lucia; Tabosa, Werner Farkatt

    2015-02-01

    Environmental monitoring studies were developed in an area located on the outer shelf in the Potiguar Basin, Brazilian equatorial margin. This tropical shelf represents a modern, highly dynamic mixed carbonate-siliciclastic system. Field sampling was carried out during 3 cruises surrounding a shallow-water exploratory well to compare sediment properties of the seafloor, including grain size, texture, mineral composition, carbonate content, and organic matter, prior to drilling with samples obtained 3 and 12 months after drilling. The sample grid used had 16 stations located along 4 radials from 50 m the well up to a distance of 500 m. Sediments were analyzed in the first 0-2 cm and 0-10 cm layers. The results show that sedimentary cover around the well is dominated by bioclastic sediments, poor to very poorly sorted. Only minor sedimentological variations occurred in the area affected by drilling operations. The most noticeable effects were observed during the second cruise, in terms of a change in grain size distribution associated to a slight increase in siliciclastic content. This impact occurred in the most surficial sediment (0-2 cm), in the radials closest to the well (50 m), and could suggest the effects of drilling. However, in the third cruise, 1 year after drilling, the sediments return to show the same characteristics as in the first cruise. These results show no significant sedimentological variations due to drilling activity and indicate that ocean dynamics in this area was high enough to recover the environment original characteristics.

  8. Responses of bluegills and black crappies to dissolved oxygen, temperature, and current in backwater lakes of the upper Mississippi River during winter

    USGS Publications Warehouse

    Knights, B.C.; Johnson, B.L.; Sandheinrich, M.B.

    1995-01-01

    We conducted a radiotelemetry study to examine the effects of dissolved oxygen (DO), water temperature, and current velocity on winter habitat selection by bluegills Lepomis macrochirus and black crappies Pomoxis nigromaculatus in the Finger Lakes backwater complex, Pool 5, on the upper Mississippi River. When DO was above 2 mg/L, both species selected areas with water temperature greater than 1 degree C and undetectable current. As dissolved oxygen concentrations fell below 2 mg/L, fish moved to areas with higher DO, despite water temperatures of 1 degree C and lower and current velocities of 1 cm/s. Areas with water temperature less than 1 degree C and current velocity greater than 1 cm/s were avoided. To incorporate the winter habitat requirements of bluegills and black crappies into habitat restoration projects, we recommend designs that allow the inflow of oxygenated water to maintain adequate DO without substantially decreasing temperature and increasing current velocity.

  9. Bald eagle winter roost characteristics in Lava Beds National Monument, California

    USGS Publications Warehouse

    Stohlgren, Thomas J.

    1993-01-01

    This study provided a survey of bald eagle (Haliaeetus leucocephalus) winter roost habitat (in 4 km2 of potential roost areas) in southern Lava Beds National Monument, California. A systematic-clustered sampling design (n=381 plots) was used to compare forest stand characteristics in two primary roost areas (Caldwell Butte and Eagle Nest Butte) and two potential roost areas (Hidden Valley and Island Butte). A 100 percent inventory of roost trees in Caldwell Butte (n=103 trees) and Eagle Nest Butte (n=44 trees) showed they were spatially clumped and restricted to 12.7 percent and 2.8 percent, respectively, of the study areas. Roost trees, primarily ponderosa pine (Pinus ponderosa), averaged 81.1 ± 1.3 cm dbh (mean ± 1 S.E.) compared to non-roost trees (>35 cm dbh) that averaged 52.2 ± 1.0 cm dbh. Roost trees were generally taller and more open-structured than non-roost trees. All four study sites had adequate numbers of mid-sized trees (10 to 50 cm dbh) to replace the current stock of older, larger roost trees. However, seedling and small trees (<10 cm dbh) in the roost areas were spatially clumped and few, suggesting that maintaining a continuous population of roost trees may be a problem in the distant future. Long-term studies of changing winter roost habitat and eagle use are essential to protect the bald eagle in the northwestern US.

  10. Final report on bilateral supplementary comparison APMP.M.P-S5 in hydraulic gauge pressure from 1 MPa to 10 MPa

    NASA Astrophysics Data System (ADS)

    Yue, J.; Yang, Y.; Sabuga, W.

    2016-01-01

    This report summarizes the results of the Asia-Pacific Metrology Programme (APMP) supplementary comparison APMP.M.P-S5 for hydraulic gauge pressure in the range of 1 MPa to 10 MPa, which is a bilateral comparison carried out at the National Institute of Metrology, China (NIM) and the Physikalisch-Technische Bundesanstalt, Germany (PTB) during the period June 2014 to June 2015. NIM piloted the comparison and provided the transfer standard, which was a piston-cylinder assembly (PCA) of 1 cm2 nominal effective area built in a hydraulic pressure balance manufactured by Fluke Corporation. The laboratory standards of NIM and PTB are both hydraulic pressure balances equipped with PCAs, of which the nominal effective area is 1 cm2 for NIM and 5 cm2 for PTB. The results of the comparison successfully demonstrated that the hydraulic gauge pressure standards of NIM and PTB in the range of 1 MPa to 10 MPa are equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Effect of different flooring systems on weight and pressure distribution on claws of dairy cows.

    PubMed

    Telezhenko, E; Bergsten, C; Magnusson, M; Ventorp, M; Nilsson, C

    2008-05-01

    Weight and pressure distribution on the claw were studied in Swedish Holsteins housed in different flooring systems. A total of 127 cows housed in different sections of the experimental barn were used. Each section had different flooring in the walking and standing areas. There were rubber mats or abrasive mastic asphalt flooring on the alleys or a low-abrasive slatted concrete floor. Some sections had feed-stalls equipped with rubber mats; other sections did not. The vertical ground reaction force, contact area, and average contact pressure were determined on the left hind foot using the I-Scan system and analyzed with the F-scan system. These determinations were made in each of the following 3 zones of the claw: bulb, wall, and sole. Most of the weight on claws exposed to concrete floors was carried by the bulb (37.4 +/- 3.5 and 18.3 +/- 2.9% of weight exerted on the foot in the lateral and medial claw, respectively) and the wall zone (20.0 +/- 2.6 and 13.4 +/- 2.4% on lateral and medial claw, respectively). The weight and pressure distribution in cows kept on sections with rubber covered alleys but passing daily over the asphalt floor on their way to the milking parlor did not differ in any zones, except for lateral bulbs, compared with those exposed to slatted concrete alone. Still, the weight bearing of the sole zone in cows kept on rubber mats without access to asphalt was less than that of cows kept on concrete slatted floors (5.1 +/- 0.7 vs. 12.7 +/- 1.1% and 1.1 +/- 0.5 vs. 8.7 +/- 0.7% in lateral and medial claws, respectively). In cows kept on asphalt flooring without feed-stalls, most weight was exerted to the sole zone (36.2 +/- 2.9 and 22.2 +/- 1.8% in lateral and medial claws, respectively). Feed-stalls in combination with asphalt flooring yielded a decreased total contact area (30.1 +/- 1.2 cm(2)) compared with asphalt floors without feed-stalls (35.7 +/- 1.2 cm(2)). The largest total contact area was obtained on the asphalt floor without feed-stalls, resulting in a lower contact pressure (39.8 +/- 2.3 N/cm(2)) than in claws exposed to concrete (66.0 +/- 2.7 N/ cm(2)) or rubber mats (56.7 +/- 1.7 N/cm(2)). In conclusion, housing with abrasive floors resulted in claws with increased contact area at the sole surface and therefore, decreased contact pressure, but reduced the weight-bearing role of the strongest part of the claw capsule, the claw wall.

  12. Sensitive Precise p H Measurement with Large-Area Graphene Field-Effect Transistors at the Quantum-Capacitance Limit

    NASA Astrophysics Data System (ADS)

    Fakih, Ibrahim; Mahvash, Farzaneh; Siaj, Mohamed; Szkopek, Thomas

    2017-10-01

    A challenge for p H sensing is decreasing the minimum measurable p H per unit bandwidth in an economical fashion. Minimizing noise to reach the inherent limit imposed by charge fluctuation remains an obstacle. We demonstrate here graphene-based ion-sensing field-effect transistors that saturate the physical limit of sensitivity, defined here as the change in electrical response with respect to p H , and achieve a precision limited by charge-fluctuation noise at the sensing layer. We present a model outlining the necessity for maximizing the device carrier mobility, active sensing area, and capacitive coupling in order to minimize noise. We encapsulate large-area graphene with an ultrathin layer of parylene, a hydrophobic polymer, and deposit an ultrathin, stoichiometric p H -sensing layer of either aluminum oxide or tantalum pentoxide. With these structures, we achieve gate capacitances ˜0.6 μ F /cm2 , approaching the quantum-capacitance limit inherent to graphene, along with a near-Nernstian p H response of ˜55 ±2 mV /p H . We observe field-effect mobilities as high as 7000 cm2 V-1 s-1 with minimal hysteresis as a result of the parylene encapsulation. A detection limit of 0.1 m p H in a 60-Hz electrical bandwidth is observed in optimized graphene transistors.

  13. Wearable Fabrics with Self-Branched Bimetallic Layered Double Hydroxide Coaxial Nanostructures for Hybrid Supercapacitors.

    PubMed

    Nagaraju, Goli; Chandra Sekhar, S; Krishna Bharat, L; Yu, Jae Su

    2017-11-28

    We report a flexible battery-type electrode based on binder-free nickel cobalt layered double hydroxide nanosheets adhered to nickel cobalt layered double hydroxide nanoflake arrays on nickel fabric (NC LDH NFAs@NSs/Ni fabric) using facile and eco-friendly synthesis methods. Herein, we utilized discarded polyester fabric as a cost-effective substrate for in situ electroless deposition of Ni, which exhibited good flexibility, light weight, and high conductivity. Subsequently, the vertically aligned NC LDH NFAs were grown on Ni fabric by means of a hot-air oven-based method, and fluffy-like NC LDH NS branches are further decorated on NC LDH NFAs by a simple electrochemical deposition method. The as-prepared core-shell-like nanoarchitectures improve the specific surface area and electrochemical activity, which provides the ideal pathways for electrolyte diffusion and charge transportation. When the electrochemical performance was tested in 1 M KOH aqueous solution, the core-shell-like NC LDH NFAs@NSs/Ni fabric electrode liberated a maximum areal capacity of 536.96 μAh/cm 2 at a current density of 2 mA/cm 2 and excellent rate capability of 78.3% at 30 mA/cm 2 (420.5 μAh/cm 2 ) with a good cycling stability. Moreover, a fabric-based hybrid supercapacitor (SC) was assembled, which achieves a stable operational potential window of 1.6 V, a large areal capacitance of 1147.23 mF/cm 2 at 3 mA/cm 2 , and a high energy density of 0.392 mWh/cm 2 at a power density of 2.353 mW/cm 2 . Utilizing such high energy storage abilities and flexible properties, the fabricated hybrid SC operated the wearable digital watch and electric motor fan for real-time applications.

  14. Association between abdominal fat distribution and atherosclerotic changes in the carotid artery.

    PubMed

    Oike, Miki; Yokokawa, Hirohide; Fukuda, Hiroshi; Haniu, Tomomi; Oka, Fukuko; Hisaoka, Teruhiko; Isonuma, Hiroshi

    2014-01-01

    We aimed to evaluate the association between abdominal fat distribution (e.g., abdominal visceral fat area [VFA], subcutaneous fat area [SFA], and total fat area [TFA]), waist circumference (WC), or body mass index (BMI) and atherosclerotic changes in the carotid artery after adjusting for common risk factors. The present study is a hospital-based, cross-sectional study. Study participants included 223 Japanese individuals who underwent a medical health checkup at Juntendo University Hospital, Tokyo, between December 2005 and August 2011. Multivariate logistic regression analysis was used to examine the association between abdominal VFA, SFA, TFA, the VFA/SFA ratio, WC, or BMI and intima-media thickness [IMT] (mean IMT≥1.1mm or maximum IMT≥1.2mm) as atherosclerotic changes in the carotid artery. Multivariate logistic regression analysis showed that VFA (OR for ≥150cm(2) versus <100cm(2), 3.88; 95% CI, 1.39-10.85), BMI (OR for ≥27.6kg/m(2) versus <25kg/m(2), 5.22; 95% CI, 1.69-16.16), and TFA (OR for 200-285cm(2) versus <200cm(2), 4.15; 95% CI, 1.34-12.86: OR for ≥285cm(2) versus <200cm(2), 5.53; 95% CI, 1.76-17.35) were significantly associated with atherosclerotic changes in men. After adjustment for BMI, only TFA (OR for ≥285cm(2) versus <200cm(2), 3.76; 95%CI, 1.03-13.79) in men was significantly associated with atherosclerotic changes in the carotid artery. Our results indicate that VFA, TFA, and BMI are independently associated with atherosclerotic changes in Japanese men. TFA may be considered as a valuable measure of atherosclerotic changes. Copyright © 2013 Asian Oceanian Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  15. Can Pillow Height Effect the Body Pressure Distribution and Sleep Comfort: a Study of Quinquagenarian Women

    NASA Astrophysics Data System (ADS)

    Li, Xinzhu; Hu, Huimin; Liao, Su

    2018-03-01

    A proper sleeping pillow can relax the neck muscles during sleep, yet does not impose stress on the spine or other tissues. By analyzing the different body pressure and subjective comfort evaluation of quinquagenarian women with different pillow heights (3cm, 7cm, 11cm and 15cm), this paper found that as the pillow height increased, the neck contact pressure, contact area and force increased at the same time, as well as the peak force and peak contact pressure gradually shifted from the head to the hip area. It was shown that the pillow with a height of 7cm was the most comfortable for supine positions.

  16. Imaging Radar in the Mojave Desert-Death Valley Region

    NASA Technical Reports Server (NTRS)

    Farr, Tom G.

    2001-01-01

    The Mojave Desert-Death Valley region has had a long history as a test bed for remote sensing techniques. Along with visible-near infrared and thermal IR sensors, imaging radars have flown and orbited over the area since the 1970's, yielding new insights into the geologic applications of these technologies. More recently, radar interferometry has been used to derive digital topographic maps of the area, supplementing the USGS 7.5' digital quadrangles currently available for nearly the entire area. As for their shorter-wavelength brethren, imaging radars were tested early in their civilian history in the Mojave Desert-Death Valley region because it contains a variety of surface types in a small area without the confounding effects of vegetation. The earliest imaging radars to be flown over the region included military tests of short-wavelength (3 cm) X-band sensors. Later, the Jet Propulsion Laboratory began its development of imaging radars with an airborne sensor, followed by the Seasat orbital radar in 1978. These systems were L-band (25 cm). Following Seasat, JPL embarked upon a series of Space Shuttle Imaging Radars: SIRA (1981), SIR-B (1984), and SIR-C (1994). The most recent in the series was the most capable radar sensor flown in space and acquired large numbers of data swaths in a variety of test areas around the world. The Mojave Desert-Death Valley region was one of those test areas, and was covered very well with 3 wavelengths, multiple polarizations, and at multiple angles. At the same time, the JPL aircraft radar program continued improving and collecting data over the Mojave Desert Death Valley region. Now called AIRSAR, the system includes 3 bands (P-band, 67 cm; L-band, 25 cm; C-band, 5 cm). Each band can collect all possible polarizations in a mode called polarimetry. In addition, AIRSAR can be operated in the TOPSAR mode wherein 2 antennas collect data interferometrically, yielding a digital elevation model (DEM). Both L-band and C-band can be operated in this way, with horizontal resolution of about 5 m and vertical errors less than 2 m. The findings and developments of these earlier investigations are discussed.

  17. Wind Turbine Drivetrain Condition Monitoring During GRC Phase 1 and Phase 2 Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, S.; Link, H.; LaCava, W.

    2011-10-01

    This report will present the wind turbine drivetrain condition monitoring (CM) research conducted under the phase 1 and phase 2 Gearbox Reliability Collaborative (GRC) tests. The rationale and approach for this drivetrain CM research, investigated CM systems, test configuration and results, and a discussion on challenges in wind turbine drivetrain CM and future research and development areas, will be presented.

  18. Simulation and Experimental Study of Bipolar Plate on the Performance PEM Fuel cell

    NASA Astrophysics Data System (ADS)

    Chinnasa, Pornchai; Khamsuk, Pattama; Seechalee, Sarunya; Swatsitang, Ekaphan

    2017-09-01

    This research is a simulated and experimental study on effects of bipolar electrodes of a PEM fuel cell on its power conversion efficiency. The PEM fuel cell structure consists of bipolar electrodes, proton exchange membrane with catalysts, flow channels of gases. This research used fuel cell of 49 cm2 in active area as a research sample and the Comsol 4.4 was employed to simulate flow channels which are serpentine pattern for anode and parallel pattern for cathode. The parameters used were calculated effects of such parameters using Comsol 4.4. After the calculation has been completed, the prototype of the PEM fuel cell were fabricated using graphite plate as electrodes which had the channel height of 0.20 cm, proton exchange membrane using carbon-platinum catalyst. Finally, further it was found that the effect of temperature on the power conversion efficiency is not severely. And for anode, the concentration of hydrogen gas was reduced 64 wt% due to the reaction whereas in parallel channel of cathode the oxygen concentration was reduced by only 6 wt% from 23 wt% at the entrance to 17 wt% at the end. The maximum power output of the prototype operated under such condition was 0.28 W/cm2 calculated from maximum power output voltage (Vmp) of 0.70 V and maximum power output current density of 0.42 A/cm2 which was in good agreement with that simulated using Comsol 4.4 which revealed the power output of 0.29 W/cm2.

  19. Monopolar radiofrequency facial tightening: a retrospective analysis of efficacy and safety in over 600 treatments.

    PubMed

    Weiss, Robert A; Weiss, Margaret A; Munavalli, Girish; Beasley, Karen L

    2006-09-01

    Monopolar radiofrequency skin heating coupled with cryogen cooling of facial skin for skin tightening has been utilized on over 10,000 patients since 2002. In order to establish the actual rate and degree of side effects in our clinical experience, a retrospective chart review was performed. Charts and clinical images of over 600 consecutive patient treatments between May 2002 and June 2006 using a monopolar radiofrequency device (Thermacool, Thermage, Haywood, CA) for skin tightening at the Maryland Laser, Skin and Vein Institute were retrospectively reviewed. The primary presentation for treatment was skin laxity of the lower face. Treatment was delivered with a 1-cm2 standard tip at fluences of 81 to 124 J/cm2 (level of 12.5 to 15), a 1-cm2 "fast" tip at fluences of 62 to 109 J/cm2 (level of 72.0 to 76.0), a 1.5-cm2 "big fast" tip at fluences of 75 to 130 J/cm2 (level of 61.5 to 65), and a 3-cm2 "bigger" tip at equivalent fluences as each became available. As treatment algorithms evolved over 4 years, the algorithm of multiple passes at lower fluence associated with better clinical outcomes and greater patient acceptance has been adopted. The most common immediate and expected clinical effects were erythema and edema lasting less than 24 hours, although 6 patients reported edema lasting for up to 1 week. There were no permanent side effects. In total, 2.7% of treatments resulted in temporary side effects, the most significant of which was a slight depression on the cheek (n = 1), which completely resolved within 3.5 months. Other side effects included localized areas of acneiform subcutaneous erythematous papules (n = 4) and a linear superficial crust (n = 1) with the original tip, all of which resolved within 1 week. One patient reported small erythematous subcutaneous nodules resolving in 17 days. Tenderness of the neck lasting from 2 weeks (n = 2) to 3 weeks (n = 1) was also reported. Our data, obtained in an office setting without injectable anesthetic or i.v. sedation, indicate that monopolar RF for skin tightening is a very safe procedure. The treatment algorithm and tips have evolved over several years leading to increased safety and efficacy. Side effects are infrequent, self-limited, and minor, comparing favorably to other nonablative devices utilized for facial rejuvenation.

  20. Characterization of X-ray Lobster Optics with a Hybrid CMOS sensor

    NASA Astrophysics Data System (ADS)

    Chattopadhyay, Tanmoy; Falcone, Abraham; Burrows, David N.; Bray, Evan; McQuaide, Maria; Kern, Matthew; Wages, Mitchell; Hull, Samuel; Inneman, Adolf; Hudec, Rene; Stehlikova, Veronika

    2018-01-01

    X-ray lobster optics provide a unique way to focus X-rays onto a small focal plane imager with wide field of view imaging. Such an instrument with angular resolution of a few arcminutes can be used to study GRB afterglows, as well as the variability and spectroscopic characteristics for various astrophysical objects. At Penn State University, we have characterized a lobster optic with an H1RG X-Ray hybrid CMOS detector (100 μm thick Silicon with 18 μm pixel size). The light-weight compact lobster optic with a 25 cm focal length provides two dimensional imaging with ~25 cm2 effective area at 2 keV. We utilize a 47 meter long X-ray beam line at Penn state University to do our experiments where we characterize the overall effective area of the instrument at 1.5 - 8 keV for both on-axis and off-axis angles. In this presentation, we will describe the characterization test stand and methods, as well as the detailed results. While this is simply a proof-of-concept experiment, such an instrument with significant collecting area can be explored for future rocket or CubeSat experiments.

  1. Progress in HTS Trapped Field Magnets: J(sub c), Area, and Applications

    NASA Technical Reports Server (NTRS)

    Weinstein, Roy; Ren, Yanru; Liu, Jian-Xiong; Sawh, Ravi; Parks, Drew; Foster, Charles; Obot, Victor; Arndt, G. Dickey; Crapo, Alan

    1995-01-01

    Progress in trapped field magnets is reported. Single YBCO grains with diameters of 2 cm are made in production quantities, while 3 cm, 4 1/2 cm and 6 cm diameters are being explored. For single grain tiles: J(sub c) - 10,000 A/sq cm for melt textured grains; J(sub c) - 40,000 A/sq cm for light ion irradiation; and J(sub c) - 85,000 A/J(sub c) for heavy ion irradiation. Using 2 cm diameter tiles bombarded by light ions, we have fabricated a mini-magnet which trapped 2.25 Tesla at 77K, and 5.3 Tesla at 65K. A previous generation of tiles, 1 cm x 1 cm, was used to trap 7.0 Tesla at 55K. Unirradiated 2.0 cm tiles were used to provide 8 magnets for an axial gap generator, in a collaborative experiment with Emerson Electric Co. This generator delivered 100 Watts to a resistive load, at 2265 rpm. In this experiment, activation of the TFMs was accomplished by a current pulse of 15 ms duration. Tiles have also been studied for application as a bumper-tether system for the soft docking of spacecraft. A method for optimizing tether forces, and mechanisms of energy dissipation are discussed. A bus bar was constructed by welding three crystals while melt-texturing, such that their a,b planes were parallel and interleaved. The bus bar, of area approx. 2 sq cm, carried a transport current of 1000 amps, the limit of the testing equipment available.

  2. Development and application of a perioral force measurement system for infants with cleft lip and palate.

    PubMed

    Zhang, Lixian; Zheng, Yaqi; Rong, Qiong; Wu, Guofeng

    2017-11-01

    Muscles converge or intertweave around the perioral area, and this can be treated with sequential therapy in infants with cleft lip and palate (CLP). The force of perioral muscles has a great influence on maxillary development and morphology. Perioral force in infants with CLP has not been well studied, and accurate and reliable measurement of perioral force in infants remains a challenge. This study aimed to investigate a new way to accurately and reliably measure perioral force in infants with unilateral CLP (UCLP) and explore the change before and after cheiloplasty. A perioral force measurement system was developed and applied to measure perioral force at labial frenum area and the commissures on both the normal and the cleft sides of four infants with UCLP before and after cheiloplasty. The results were analyzed using the SPSS 19.0 software. The perioral force measurement system appears to produce valid results in infants with UCLP. Before cheiloplasty, the perioral force of labial frenum area was 1.79 ± 0.94 g/cm 2 and that of commissure on the normal and cleft sides was 5.41 ± 1.01 g/cm 2 and 3.12 ± 1.55 g/cm 2 , respectively (P < 0.05). After cheiloplasty, perioral force of labial frenum area was 12.73 ± 3.51 g/cm 2 and that of commissure on the normal and cleft sides was 7.64 ± 1.64 g/cm 2 and 7.27 ± 1.89 g/cm 2 , respectively (P > 0.05). Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Defining the value of injection current and effective electrical contact area for EGaIn-based molecular tunneling junctions.

    PubMed

    Simeone, Felice C; Yoon, Hyo Jae; Thuo, Martin M; Barber, Jabulani R; Smith, Barbara; Whitesides, George M

    2013-12-04

    Analysis of rates of tunneling across self-assembled monolayers (SAMs) of n-alkanethiolates SCn (with n = number of carbon atoms) incorporated in junctions having structure Ag(TS)-SAM//Ga2O3/EGaIn leads to a value for the injection tunnel current density J0 (i.e., the current flowing through an ideal junction with n = 0) of 10(3.6±0.3) A·cm(-2) (V = +0.5 V). This estimation of J0 does not involve an extrapolation in length, because it was possible to measure current densities across SAMs over the range of lengths n = 1-18. This value of J0 is estimated under the assumption that values of the geometrical contact area equal the values of the effective electrical contact area. Detailed experimental analysis, however, indicates that the roughness of the Ga2O3 layer, and that of the Ag(TS)-SAM, determine values of the effective electrical contact area that are ~10(-4) the corresponding values of the geometrical contact area. Conversion of the values of geometrical contact area into the corresponding values of effective electrical contact area results in J0(+0.5 V) = 10(7.6±0.8) A·cm(-2), which is compatible with values reported for junctions using top-electrodes of evaporated Au, and graphene, and also comparable with values of J0 estimated from tunneling through single molecules. For these EGaIn-based junctions, the value of the tunneling decay factor β (β = 0.75 ± 0.02 Å(-1); β = 0.92 ± 0.02 nC(-1)) falls within the consensus range across different types of junctions (β = 0.73-0.89 Å(-1); β = 0.9-1.1 nC(-1)). A comparison of the characteristics of conical Ga2O3/EGaIn tips with the characteristics of other top-electrodes suggests that the EGaIn-based electrodes provide a particularly attractive technology for physical-organic studies of charge transport across SAMs.

  4. All-solid-state Al-air batteries with polymer alkaline gel electrolyte

    NASA Astrophysics Data System (ADS)

    Zhang, Zhao; Zuo, Chuncheng; Liu, Zihui; Yu, Ying; Zuo, Yuxin; Song, Yu

    2014-04-01

    Aluminum-air (Al-air) battery is one of the most promising candidates for next-generation energy storage systems because of its high capacity and energy density, and abundance. The polyacrylic acid (PAA)-based alkaline gel electrolyte is used in all-solid-state Al-air batteries instead of aqueous electrolytes to prevent leakage. The optimal gel electrolyte exhibits an ionic conductivity of 460 mS cm-1, which is close to that of aqueous electrolytes. The Al-air battery peak capacity and energy density considering only Al can reach 1166 mAh g-1-Al and 1230 mWh g-1-Al, respectively, during constant current discharge. The battery prototype also exhibits a high power density of 91.13 mW cm-2. For the battery is a laminated structure, area densities of 29.2 mAh cm-2 and 30.8 mWh cm-2 are presented to appraise the performance of the whole cell. A novel design to inhibit anodic corrosion is proposed by separating the Al anode from the gel electrolyte when not in use, thereby effectively maintaining the available capacity of the battery.

  5. A comparative study of retentive strengths of zinc phosphate, polycarboxylate and glass ionomer cements with stainless steel crowns - an in vitro study.

    PubMed

    Raghunath Reddy, M H; Subba Reddy, V V; Basappa, N

    2010-01-01

    An in vitro study was conducted to compare the retentive strengths of zinc phosphate, polycarboxylate and glass ionomer cements using Instron universal testing machine. Thirty preformed and pretrimmed stainless steel crowns were used for cementation on 30 extracted human primary molars which were divided into three groups of 10 teeth in each group. Then the teeth were stored in artificial saliva and incubated at 37°C for 24 h. A load was applied on to the crown and was gradually increased till the crown showed dislodgement, and then the readings were recorded using Instron recorder and analyzed for statistical significance. The surface area of crown was measured by graphical method. The retentive strength was expressed in terms of kg/cm 2 , which was calculated by the equation load divided by area. Retentive strengths of zinc phosphate (ranged from a minimum of 16.93 to amaximum of 28.13 kg/cm 2 with mean of 21.28 kg/cm 2 ) and glass ionomer cement (minimum of 13.69 - 28.15 kg/cm 2 with mean of 20.69 kg/cm 2 ) were greater than that of polycarboxylate cement (minimum of 13.26 - 22.69 kg/cm 2 with mean of 16.79 kg/cm 2 ). Negligible difference (0.59 kg/cm 2 ) of retentive strength was observed between zinc phosphate (21.28 kg/cm 2 ) and glass ionomer cements (20.69 kg/cm 2 ). Glass ionomer cements can be recommended for cementation of stainless steel crowns because of its advantages and the retentive strength was almost similar to that of zinc phosphate cement.

  6. Measurements of Tropospheric NO2 in Romania Using a Zenith-Sky Mobile DOAS System and Comparisons with Satellite Observations

    PubMed Central

    Constantin, Daniel-Eduard; Merlaud, Alexis; Van Roozendael, Michel; Voiculescu, Mirela; Fayt, Caroline; Hendrick, François; Pinardi, Gaia; Georgescu, Lucian

    2013-01-01

    In this paper we present a new method for retrieving tropospheric NO2 Vertical Column Density (VCD) from zenith-sky Differential Optical Absorption Spectroscopy (DOAS) measurements using mobile observations. This method was used during three days in the summer of 2011 in Romania, being to our knowledge the first mobile DOAS measurements peformed in this country. The measurements were carried out over large and different areas using a mobile DOAS system installed in a car. We present here a step-by-step retrieval of tropospheric VCD using complementary observations from ground and space which take into account the stratospheric contribution, which is a step forward compared to other similar studies. The detailed error budget indicates that the typical uncertainty on the retrieved NO2tropospheric VCD is less than 25%. The resulting ground-based data set is compared to satellite measurements from the Ozone Monitoring Instrument (OMI) and the Global Ozone Monitoring Experiment-2 (GOME-2). For instance, on 18 July 2011, in an industrial area located at 47.03°N, 22.45°E, GOME-2 observes a tropospheric VCD value of (3.4 ± 1.9) × 1015 molec./cm2, while average mobile measurements in the same area give a value of (3.4 ± 0.7) × 1015 molec./cm2. On 22 August 2011, around Ploiesti city (44.99°N, 26.1°E), the tropospheric VCD observed by satellites is (3.3 ± 1.9) × 1015 molec./cm2 (GOME-2) and (3.2 ± 3.2) × 1015 molec./cm2 (OMI), while average mobile measurements give (3.8 ± 0.8) × 1015 molec./cm2. Average ground measurements over “clean areas”, on 18 July 2011, give (2.5 ± 0.6) × 1015 molec./cm2 while the satellite observes a value of (1.8 ± 1.3) × 1015 molec./cm2. PMID:23519349

  7. CROSS-DISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Excellent Passivation of p-Type Si Surface by Sol-Gel Al2O3 Films

    NASA Astrophysics Data System (ADS)

    Xiao, Hai-Qing; Zhou, Chun-Lan; Cao, Xiao-Ning; Wang, Wen-Jing; Zhao, Lei; Li, Hai-Ling; Diao, Hong-Wei

    2009-08-01

    Al2O3 films with a thickness of about 100 nm synthesized by spin coating and thermally treated are applied for field-induced surface passivation of p-type crystalline silicon. The level of surface passivation is determined by techniques based on photoconductance. An effective surface recombination velocity below 100 cm/s is obtained on 10Ω ·cm p-type c-Si wafers (Cz Si). A high density of negative fixed charges in the order of 1012 cm-2 is detected in the Al2O3 films and its impact on the level of surface passivation is demonstrated experimentally. Furthermore, a comparison between the surface passivation achieved for thermal SiO2 and plasma enhanced chemical vapor deposition SiNx:H films on the same c-Si is presented. The high negative fixed charge density explains the excellent passivation of p-type c-Si by Al2O3.

  8. Radiation induced COX-2 expression and mutagenesis at non-targeted lung tissues of gpt delta transgenic mice

    PubMed Central

    Chai, Y; Calaf, G M; Zhou, H; Ghandhi, S A; Elliston, C D; Wen, G; Nohmi, T; Amundson, S A; Hei, T K

    2013-01-01

    Background: Although radiation-induced bystander effects have been confirmed using a variety of endpoints, the mechanism(s) underlying these effects are not well understood, especially for in vivo study. Methods: A 1-cm2 area (1 cm × 1 cm) in the lower abdominal region of gpt delta transgenic mice was irradiated with 5 Gy of 300 keV X-rays, and changes in out-of-field lung and liver were observed. Results: Compared with sham-treated controls, the Spi− mutation frequency increased 2.4-fold in non-targeted lung tissues at 24 h after partial body irradiation (PBIR). Consistent with dramatic Cyclooxygenase 2 (COX-2) induction in the non-targeted bronchial epithelial cells, increasing levels of prostaglandin, together with 8-hydroxydeoxyguanosine, in the out-of-field lung tissues were observed after PBIR. In addition, DNA double-strand breaks and apoptosis were induced in bystander lung tissues after PBIR. Conclusion: The PBIR induces DNA damage and mutagenesis in non-targeted lung tissues, especially in bronchial epithelial cells, and COX-2 has an essential role in bystander mutagenesis. PMID:23321513

  9. Nitrogen Dioxide pollution and hazardous household environment: what impacts more congenital malformations.

    PubMed

    Landau, D; Novack, L; Yitshak-Sade, M; Sarov, B; Kloog, I; Hershkovitz, R; Grotto, I; Karakis, I

    2015-11-01

    Nitrogen Dioxide (NO2) is a product of fuel combustion originating mainly from industry and transportation. Studies suggest an association between NO2 and congenital malformations (CM). We investigated an independent effect of NO2 on CM by adjusting to individual factors and household environment in 1024 Bedouin-Arab pregnant women in southern Israel. This population is characterised by high rates of CMs, frequent consanguineous marriages, paternal smoking, temporary housing and usage of open fire for heat cooking. Information on household risk factors was collected during an interview. Ambient measurements of 24-h average NO2 and meteorological conditions were obtained from 13 local monitors. Median value of daily NO2 measured in the area was 6.78ppb. CM was diagnosed in 8.0% (82) of offspring. Maternal NO2 exposure during the 1st trimester >8.6ppb was significantly associated with minor CM (RR=2.68, p=0.029). Major CM were independently associated with maternal juvenile diabetes (RR=9.97, p-value=0.002) and heating by open fire (RR=2.00, p-value=0.049), but not NO2 exposure. We found that NO2 emissions had an independent impact only on minor malformations, whereas major malformations depended mostly on the household environment. Antepartum deaths were associated by maternal morbidity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Efficiency and concentration ratio measurements of fluorescent solar concentrators using a xenon measurement system.

    PubMed

    Heidler, K

    1981-03-01

    An indoor test stand for fluorescent planar concentrator-collectors (FPC) with a 1.6-kW xenon light source, irradiating a rectangular triangle (active area 400 cm(2)) with 82 mW cm(-2), and a typical homogeneity of +/-10% is described in detail. Conditions and definitions for the efficiency measurements are discussed, taking intensity and reflection effects into account. As an illustration FPC efficiency and concentration ratios are reported (best optical efficiency was 7.5% for a single-plate one-dye FPC), the influence of thickness variation is discussed, and an enhancement in solar cell efficiency is demonstrated.

  11. Radial tunnel diodes based on InP/InGaAs core-shell nanowires

    NASA Astrophysics Data System (ADS)

    Tizno, Ofogh; Ganjipour, Bahram; Heurlin, Magnus; Thelander, Claes; Borgström, Magnus T.; Samuelson, Lars

    2017-03-01

    We report on the fabrication and characterization of radial tunnel diodes based on InP(n+)/InGaAs(p+) core-shell nanowires, where the effect of Zn-dopant precursor flow on the electrical properties of the devices is evaluated. Selective and local etching of the InGaAs shell is employed to access the nanowire core in the contact process. Devices with an n+-p doping profile show normal diode rectification, whereas n+-p+ junctions exhibit typical tunnel diode characteristics with peak-to-valley current ratios up to 14 at room temperature and 100 at 4.2 K. A maximum peak current density of 28 A/cm2 and a reverse current density of 7.3 kA/cm2 at VSD = -0.5 V are extracted at room temperature after normalization with the effective junction area.

  12. Response of pigmented porcine skin (Sus scrofa domestica) to single 3.8-micron laser radiation pulses

    NASA Astrophysics Data System (ADS)

    Bostick, Anthony C.; Johnson, Thomas E.; Randolph, Donald Q.; Winston, Golda C. H.

    2005-04-01

    Background and purpose: The purpose of this study is to determine the impact of melanin on skin response to single 3.8 micron, eight microsecond laser pulses and the difference in lesion formation thresholds for input into laser safety standards. Williams et al., performed a study examining laser tissue interaction from 3.8-micron lasers in lightly pigmented Yorkshire pigs (Sus scrofa domestica). However, studies performed by Eggleston et al comparing pigmented and lightly pigmented skin with human skin found that the Yucatan mini-pig is a superior model for laser skin exposures. Methods: Five Yucatan mini-pigs under general anesthesia were exposed to 3.8 micron laser pulses ranging from 0.8 J/cm2 to 93 J/cm2. Gross examinations were done acutely and 24 hours after laser exposure. Skin biopsies were then collected at various times post exposure, and histologic examinations were conducted. Results: The 24 hour ED50 was determined to be 4.5 J/cm2 with fiducial limits of 6.2 and 2.2 J/cm2. As deposited energy was increased, the lesion presentation ranged from whitening of the epidermis (4 J/cm2) to whitening with inflammatory centers (14 J/cm2), and at the highest energy levels inflammatory areas were replaced with an epidermal ulcerated central area (>21 J/cm2). Conclusion: Preliminary findings suggest pigmentation or melanin may play a minor role in the mechanism of laser-tissue damage. The ED50 of Yorkshire pigs was 2.6 J/cm2. The ED50 of the Yucatan mini-pig was found to be 3.6 J/cm2, and although it was higher, it is still within the 95% fiducial limits.

  13. Distribution of Thyroid Cancer in the Eastern Part of Turkey 27 Years After the Chernobyl Accident.

    PubMed

    Sahin, Serap Baydur; Yucel, Ahmet Fikret; Gucer, Hasan; Pergel, Ahmet; Bedir, Recep; Aydin, Ibrahim; Sehitoglu, Ibrahim; Sahin, Dursun Ali; Sahin, Osman Zikrullah

    2013-12-01

    The Chernobyl accident caused widespread effects across Europe and huge areas where radiocontaminated. The effects of the Chernobyl accident on thyroid cancer have been investigated in most European countries. According to the data of the Turkish Atomic Energy Authority, the eastern part of the Black Sea region was the most radiocontaminated area in Turkey at the time of Chernobyl accident. We therefore aimed to examine the data of thyroid cancers at our center, Rize city which is located in the eastern Black Sea region. This retrospective study included the patients with histologically proven thyroid cancer at our center between January 2008 and May 2012. Pathologic examinations of thyroidectomy materials were reviewed. We evaluated patients' age, gender, size of the primary tumor (all sizes, < 1 cm, 1 - 2.9 cm, 3 - 3.9 cm and ≥ 4 cm), multicentricity, histologic subtypes of thyroid cancer, the presence of lymphatic, vascular, capsule and the extrathyroidal invasion. Five hundred and forty-seven of the 3,556 patients were diagnosed with thyroid cancer. The mean age of the patients was 49.31 ± 0.49 years. The histopathologic diagnosis of patients was papillary carcinoma in 533 (97.4%) and the tumor size was < 1 cm in 53.6% of the patients. The presence of multicentricity was detected in 47% of the patients. The portion of thyroid carcinomas in all thyroidectomies was 15.4% in our institution 27 years after the Chernobyl accident.

  14. Distribution of Thyroid Cancer in the Eastern Part of Turkey 27 Years After the Chernobyl Accident

    PubMed Central

    Sahin, Serap Baydur; Yucel, Ahmet Fikret; Gucer, Hasan; Pergel, Ahmet; Bedir, Recep; Aydin, Ibrahim; Sehitoglu, Ibrahim; Sahin, Dursun Ali; Sahin, Osman Zikrullah

    2013-01-01

    Background The Chernobyl accident caused widespread effects across Europe and huge areas where radiocontaminated. The effects of the Chernobyl accident on thyroid cancer have been investigated in most European countries. According to the data of the Turkish Atomic Energy Authority, the eastern part of the Black Sea region was the most radiocontaminated area in Turkey at the time of Chernobyl accident. We therefore aimed to examine the data of thyroid cancers at our center, Rize city which is located in the eastern Black Sea region. Methods This retrospective study included the patients with histologically proven thyroid cancer at our center between January 2008 and May 2012. Pathologic examinations of thyroidectomy materials were reviewed. We evaluated patients’ age, gender, size of the primary tumor (all sizes, < 1 cm, 1 - 2.9 cm, 3 - 3.9 cm and ≥ 4 cm), multicentricity, histologic subtypes of thyroid cancer, the presence of lymphatic, vascular, capsule and the extrathyroidal invasion. Results Five hundred and forty-seven of the 3,556 patients were diagnosed with thyroid cancer. The mean age of the patients was 49.31 ± 0.49 years. The histopathologic diagnosis of patients was papillary carcinoma in 533 (97.4%) and the tumor size was < 1 cm in 53.6% of the patients. The presence of multicentricity was detected in 47% of the patients. Conclusion The portion of thyroid carcinomas in all thyroidectomies was 15.4% in our institution 27 years after the Chernobyl accident. PMID:29147362

  15. Tailored minimally invasive management of complex calculi in horseshoe kidney.

    PubMed

    Ding, Jie; Zhang, Yuanyuan; Cao, Qifeng; Huang, Tao; Xu, Wei; Huang, Kai; Fang, Jing; Bai, Qiang; Qi, Jun; Huang, Yunteng

    2015-01-01

    Complex calculi in horseshoe kidney (HK) present a significant management challenge. Here, we report the clinical efficacy of extracorporeal shock wave lithotripsy (ESWL), minimally invasive percutaneous nephrolithotomy (MPCNL) and flexible ureteroscopy (FURS), combined with holmium laser lithotripsy, in the treatment of calculi in HK. From January 2005 to May 2014, 62 HK patients with renal calculi were reviewed in terms of medical history, treatment modality and therapeutic outcome in a single tertiary care hospital. Among the patients, 11 with a solitary stone ≤ 1.5 cm in diameter received ESWL, leading to overall stone-free rate of 72.7%; 18 with stone diameter ≤ 2-3 cm received retrograde flexible ureteroscopy, with a recorded mean digitized surface area (DSA) of 339.6 ± 103.9 mm2, mean operation time of 93.1 ± 11.5 minutes and overall stone-free rate of 88.9%; and 33 with staghorn or complex calculi (d ≥ 2 cm) had MPCNL or MPCNL-FURS, with a recorded mean DSA of 691.0 ± 329.9 vs. 802.9 ± 333.3 mm2, mean operation time of 106.4 ± 16.6 vs. 124.4 ± 15.1 min and overall stone-free rate of 89.5% vs. 92.9%. For complex calculi (d ≥ 2 cm), MPCNL combined with antegrade FURS was superior in terms of reducing number of tracts, controlling mean hemoglobin drop, but required longer operation time, comparing with MPCNL alone. As minimally invasive treatments, a combination of MPCNL and antegrade FURS provides a safe and effective modality in the management of staghorn or complex calculi (d ≥ 2 cm) in HK with significantly reduced blood loss comparing to MPCNL alone, and retrograde FURS alone is favorable for stones with a diameter ≤ 2-3 cm. ESWL is effective for viable small solitary stones (d ≤ 1.5 cm). Treatment modality should be tailored based on individual condition.

  16. A SPECT Scanner for Rodent Imaging Based on Small-Area Gamma Cameras

    NASA Astrophysics Data System (ADS)

    Lage, Eduardo; Villena, José L.; Tapias, Gustavo; Martinez, Naira P.; Soto-Montenegro, Maria L.; Abella, Mónica; Sisniega, Alejandro; Pino, Francisco; Ros, Domènec; Pavia, Javier; Desco, Manuel; Vaquero, Juan J.

    2010-10-01

    We developed a cost-effective SPECT scanner prototype (rSPECT) for in vivo imaging of rodents based on small-area gamma cameras. Each detector consists of a position-sensitive photomultiplier tube (PS-PMT) coupled to a 30 x 30 Nal(Tl) scintillator array and electronics attached to the PS-PMT sockets for adapting the detector signals to an in-house developed data acquisition system. The detector components are enclosed in a lead-shielded case with a receptacle to insert the collimators. System performance was assessed using 99mTc for a high-resolution parallel-hole collimator, and for a 0.75-mm pinhole collimator with a 60° aperture angle and a 42-mm collimator length. The energy resolution is about 10.7% of the photopeak energy. The overall system sensitivity is about 3 cps/μCi/detector and planar spatial resolution ranges from 2.4 mm at 1 cm source-to-collimator distance to 4.1 mm at 4.5 cm with parallel-hole collimators. With pinhole collimators planar spatial resolution ranges from 1.2 mm at 1 cm source-to-collimator distance to 2.4 mm at 4.5 cm; sensitivity at these distances ranges from 2.8 to 0.5 cps/μCi/detector. Tomographic hot-rod phantom images are presented together with images of bone, myocardium and brain of living rodents to demonstrate the feasibility of preclinical small-animal studies with the rSPECT.

  17. Cerebral malaria as a risk factor for the development of epilepsy and other long-term neurological conditions: a meta-analysis.

    PubMed

    Christensen, Stephanie S; Eslick, Guy D

    2015-04-01

    Cerebral malaria (CM) is the most common and severe acute neurological manifestation of Plasmodium falciparum malaria. Children living in malaria-endemic areas of sub-Saharan Africa are at the highest risk of developing CM, and the long-term effect of CM on neurological function is uncertain. We conducted a meta-analysis to quantitatively assess the association between CM and development of long-term neurological impairment. We performed a systematic search through PubMed (including MEDLINE; 1946 to December 2014) and EMBASE (1974 to January 2015) to identify relevant articles. Eligible studies assessed the association between CM and neurological sequelae and were included if they met the criteria allowing a complete extraction of data. Eight studies were included in the final analysis, and in total, 2005 individuals were analysed (cases: n=842, controls: n=1163), most of whom were children. CM was associated with an increased risk of epilepsy (OR 4.68, 95% CI: 2.52-8.70), an increased risk of intelligence quotient (IQ) impairment (OR 4.72, 95% CI: 0.78-28.49), an increased risk of neurodisabilities (OR 16.16, 95% CI: 1.34-195.45), and an increased risk of behavioural disorder (OR 8.47, 95% CI: 2.75-26.04). Our findings suggest that children who survive CM are at increased risk of long-term neurological adverse outcome, including epilepsy. This may present a major public health problem in terms of education and development in malaria-endemic areas. Measures to avoid neurological morbidity are warranted. © The Author 2015. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. The Effect of Commonly Performed Exercises on the Levator Hiatus Area and the Length and Strength of Pelvic Floor Muscles in Postpartum Women.

    PubMed

    Siff, Lauren N; Hill, Audra J; Walters, Samantha J; Walters, Ginny; Walters, Mark D

    2018-05-02

    The aim oft his study was to compare the effects of 10 common exercises to traditional pelvic floor muscle (PFM) contractions (Kegel) on levator hiatus (LH) area and PFM length and strength. This is a cross-sectional study of 15 healthy postpartum women. Ten exercises were studied. These were common variations of leg, core, and back exercises used in yoga, Pilates, strength training, and physical therapy. Each participant performed all 10 exercises at a single visit in 2 examination settings: transperineal ultrasound and perineometry. Ultrasound measured the LH area and PFM length, and perineometry measured the muscle strength (peak squeeze pressure). Kegel generates an increase in squeeze pressure (24.3 cm H2O), shortens the muscles (-0.46 cm) and narrows the LH (-0.13 cm). The bird-dog and plank exercises were not different from Kegel in any measurement. While the leg-lift ultrasound dimensions are similar to Kegel, leg lifts generated peak squeeze pressures stronger than any other exercise (including Kegel). Whereas ultrasound dimensions were similar to Kegel, tucked and untucked squats and thigh adductions generated weaker contractions than Kegel. While crunch generated a squeeze pressure similar to Kegel, the ultrasound dimensions showed a significantly wider LH and longer muscle than Kegel. Bridge, clam, and plié exercises affected the PFMs differently than Kegel in all measures. Bird-dog, plank, and leg-lift exercises should be evaluated as alternative exercises to Kegel as they affect PFM strength and length and LH area similarly to Kegel, and leg lifts generate a stronger contraction than Kegel.

  19. Loblolly pine regeneration and competing vegetation 5 years after implementing uneven-aged silviculture

    Treesearch

    Michael G. Shelton; Paul A. Murphy

    1994-01-01

    Thc effects of three basal areas (9.2, 133, and 18.4 m2/ha), maximum diameters (30.5. 40.6, and 50.8 cm), and site indices (24.6, 24.7-27.4, and >27.5 m at 50 years) on establishment and development of loblolly pine (Pinus taeda L.) regeneration and competing vegetation were...

  20. Membrane lateral compressibility determined by NMR and x-ray diffraction: effect of acyl chain polyunsaturation.

    PubMed Central

    Koenig, B W; Strey, H H; Gawrisch, K

    1997-01-01

    The elastic area compressibility modulus, Ka, of lamellar liquid crystalline bilayers was determined by a new experimental approach using 2H-NMR order parameters of lipid hydrocarbon chains together with lamellar repeat spacings measured by x-ray diffraction. The combination of NMR and x-ray techniques yields accurate determination of lateral area per lipid molecule. Samples of saturated, monounsaturated, and polyunsaturated phospholipids were equilibrated with polyethylene glycol (PEG) 20,000 solutions in water at concentrations from 0 to 55 wt % PEG at 30 degrees C. This procedure is equivalent to applying 0 to 8 dyn/cm lateral pressure to the bilayers. The resulting reductions in area per lipid were measured with a resolution of +/-0.2 A2 and the fractional area decrease was proportional to applied lateral pressure. For 1,2-dimyristoyl(d54)-sn-glycero-3-phosphocholine, 1-stearoyl(d35)-2-oleoyl-sn-glycero-3-phosphocholine (SOPC-d35), and 1-stearoyl(d35)-2-docosahexaenoyl-sn-glycero-3-phosphocholine (SDPC-d35) cross-sectional areas per molecule in excess water of 59.5, 61.4, and 69.2 A2 and bilayer elastic area compressibility moduli of 141, 221, and 121 dyn/cm were determined, respectively. Combining NMR and x-ray results enables the determination of compressibility differences between saturated and unsaturated hydrocarbon chains. In mixed-chain SOPC-d35 both chains have similar compressibility moduli; however, in mixed-chain polyunsaturated SDPC-d35, the saturated stearic acid chain appears to be far less compressible than the polyunsaturated docosahexaenoic acid chain. Images FIGURE 3 FIGURE 5 PMID:9336191

  1. Effects of experimental warming on soil temperature, moisture and respiration in northern Mongolia

    NASA Astrophysics Data System (ADS)

    Sharkhuu, A.; Plante, A. F.; Casper, B. B.; Helliker, B. R.; Liancourt, P.; Boldgiv, B.; Petraitis, P.

    2010-12-01

    Mean annual air temperature in the Lake Hövsgöl region of northern Mongolia has increased by 1.8 °C over the last 40 years, greater than global average temperature increases. A decrease of soil moisture due to changes in precipitation regime is also predicted over the northern region of Mongolia. Warmer temperatures generally result in higher soil CO2 efflux, but responses of soil efflux to climate change may differ among ecosystems due to response variations in soil temperature and moisture regime. The objectives of our study were to examine the environmental responses (soil temperature and moisture) to experimental warming, and to test responses of soil CO2 efflux to experimental warming, in three different ecozones. The experimental site is located in Dalbay Valley, on the eastern shore of Lake Hövsgöl in northern Mongolia (51.0234° N 100.7600° E; 1670 m elevation). Replicate plots with ITEX-style open-top passive warming chambers (OTC) and non-warmed control areas were installed in three ecosystems: (1) semi-arid grassland on the south-facing slope not underlain by permafrost, (2) riparian zone, and (3) larch forest on the north-facing slope underlain by permafrost. Aboveground air temperature and belowground soil temperature and moisture (10 and 20 cm) were monitored using sensors and dataloggers. Soil CO2 efflux was measured periodically using a portable infra-red gas analyzer with an attached soil respiration chamber. The warming chambers were installed and data collected during the 2009 and 2010 growing seasons. Passive warming chambers increased nighttime air temperatures; more so in grassland compared to the forest. Increases in daytime air temperatures were observed in the grassland, but were not significant in the riparian and forest areas. Soil temperatures in warmed plots were consistently higher in all three ecozones at 10 cm depth but not at 20 cm depth. Warming chambers had a slight drying effect in the grassland, but no consistent effect in forest and riparian areas. Measured soil CO2 efflux rates were highest in riparian area, and lowest in the grassland. Initial results of soil efflux measurements suggest that the effect of warming treatment significantly depends on the ecosystem type: soil efflux rates differed between warming treatments in forest plots, but not in riparian and grassland plots.

  2. Development of on-site PAFC stacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hotta, K.; Matsumoto, Y.; Horiuchi, H.

    1996-12-31

    PAFC (Phosphoric Acid Fuel Cell) has been researched for commercial use and demonstration plants have been installed in various sites. However, PAFC don`t have a enough stability yet, so more research and development must be required in the future. Especially, cell stack needs a proper state of three phases (liquid, gas and solid) interface. It is very difficult technology to keep this condition for a long time. In the small size cell with the electrode area of 100 cm{sup 2}, gas flow and temperature distributions show uniformity. But in the large size cell with the electrode area of 4000 cm{supmore » 2}, the temperature distributions show non-uniformity. These distributions would cause to be shorten the cell life. Because these distributions make hot-spot and gas poverty in limited parts. So we inserted thermocouples in short-stack for measuring three-dimensional temperature distributions and observed effects of current density and gas utilization on temperature.« less

  3. SU-E-CAMPUS-I-01: Nanometric Organic Photovoltaic Thin Film X-Ray Detectors for Clinical KVp Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elshahat, Bassem; Gill, Hardeep; Kumar, Jayant

    2014-06-15

    Purpose: To fabricate and test nanometric organic photovoltaic (OPV) cells made of various active-layer/electrode thicknesses and sizes; to determine the optimal material combinations and geometries suitable for dose measurements in clinical kilovoltage x-ray beams. Methods: The OPV consisted of P3HT:PCBM photoactive materials sandwiched between aluminum and Indium Tin Oxide (ITO) electrodes. Direct conversion of xrays in the active layer composed of donor and acceptor semiconducting organic materials generated signal in photovoltaic mode (without external voltage bias). OPV cells were fabricated with different active layer thicknesses (150, 270, 370 nm) and electrode areas (0.4, 0.7, 0.9, 1.4, 2.6 cm{sup 2}). Amore » series of experiments were preformed in the energy range of 60–150 kVp. The net current per unit area (nA/cm{sup 2}) was measured using 200 mAs time-integrated beam current. Results: The net OPV current as function of beam energy (kVp) was proportional to ∼E{sup 0,4} {sup 5} when adjusted for beam output. The best combination of parameters for these cells was 270 nm active layer thicknesses for 0.7 cm{sup 2} electrode area. The measured current ranged from 0.69 to 2.43 nA/cm{sup 2} as a function of x-ray energy between 60 and 150 kVp, corresponding to 0.09 – 0.06 nA/cm{sup 2}/mGy, respectively, when adjusted for the beam output. Conclusion: The experiments indicate that OPV detectors possessing 270 nm active layer and 0.7 cm{sup 2} Al electrode areas have sensitivity by a factor of 2.5 greater than commercial aSi thin film PV. Because OPV can be made flexible and they do not require highvoltage bias supply, they open the possibility for using as in-vivo detectors in radiation safety in x-ray imaging beams.« less

  4. Aspen height, stem-girth and survivorship in an area of high ungulate use

    USGS Publications Warehouse

    Keigley, R.B.; Frisina, M.R.

    2008-01-01

    An increase in ungulate population size potentially exposes aspen suckers, saplings, and trees to increased use. This study examined how stem height and girth influenced the selection of stems by ungulates for browsing, rubbing, and gnawing, and reconstructed the history of ungulate use for the study area. Transects were run through each of three aspen clones growing in southwestern Montana to determine height, circumference, and the surface area from which bark was totally and partially removed by rubbing and gnawing. Stems 20-250 cm tall were browsed. Stems 2-13 cm diameter were preferentially selected for rubbing and gnawing. The area of totally removed bark on dead saplings was twice the area of removed bark on live stems of similar diameter, suggesting that bark removal played a major role in the death of some stems. Based on an analysis of stem height and age, ungulate browsing was inferred to have increased from a light-to-moderate level to an intense level in 1991. The depth of scars was used to date scarring events. An increase in rubbing and gnawing was determined to have occurred about 1985. We concluded that elk were primarily responsible for the observed impacts. The combined effect of rubbing, gnawing, and browsing affects a broader span of ages compared to the effect of browsing alone. If prescribed fire is used to rejuvenate aspen stands, the resulting young stems should be protected from heavy browsing, rubbing and gnawing until they reach about 13 cm diameter and have grown out of the browse zone.

  5. Effect of facility variation on the acoustic characteristics of three single stream nozzles

    NASA Technical Reports Server (NTRS)

    Gutierrez, O. A.

    1980-01-01

    The characteristics of the jet noise produced by three single stream nozzles were investigated statistically at the NASA-Lewis Research Center outdoor jet acoustic facility. The nozzles consisted of a 7.6 cm diameter convergent conical, a 10.2 cm diameter convergent conical and an 8-lobe daisy nozzle with 7.6 cm equivalent diameter flow area. The same nozzles were tested previously at cold flow conditions in other facilities such as the Royal Aircraft Establishment (RAE) 7.3 m acoustic wind tunnel. The acoustic experiments at NASA covered pressure ratios from 1.4 to 2.5 at total temperatures of 811 K and ambient. The data obtained with four different microphone arrays are compared. The results are also compared with data taken at the RAE facility and with a NASA prediction procedure.

  6. Electrostatic modulation of the electronic properties of Dirac semimetal Na3Bi thin films

    NASA Astrophysics Data System (ADS)

    Hellerstedt, Jack; Yudhistira, Indra; Edmonds, Mark T.; Liu, Chang; Collins, James; Adam, Shaffique; Fuhrer, Michael S.

    2017-10-01

    Large-area thin films of topological Dirac semimetal Na3Bi are grown on amorphous SiO2:Si substrates to realize a field-effect transistor with the doped Si acting as a back gate. As-grown films show charge carrier mobilities exceeding 7 000 cm2/V s and carrier densities below 3 ×1018cm-3 , comparable to the best thin-film Na3Bi . An ambipolar field effect and minimum conductivity are observed, characteristic of Dirac electronic systems. The results are quantitatively understood within a model of disorder-induced charge inhomogeneity in topological Dirac semimetals. The hole mobility is significantly larger than the electron mobility in Na3Bi which we ascribe to the inverted band structure. When present, these holes dominate the transport properties.

  7. Second generation large area microchannel plate flat panel phototubes

    NASA Astrophysics Data System (ADS)

    Ertley, C. D.; Siegmund, O. H. W.; Jelinsky, S. R.; Tedesco, J.; Minot, M. J.; O'Mahony, A.; Craven, C. A.; Popecki, M.; Lyashenko, A. V.; Foley, M. R.

    2016-07-01

    Very large (20 cm × 20 cm) flat panel phototubes are being developed which employ novel microchannel plates (MCPs). The MCPs are manufactured using borosilicate microcapillary arrays which are functionalized by the application of resistive and secondary emissive layers using atomic layer deposition (ALD). This allows the operational parameters to be set by tailoring sequential ALD deposition processes. The borosilicate substrates are robust, including the ability to be produced in large formats (20 cm square). ALD MCPs have performance characteristics (gain, pulse amplitude distributions, and imaging) that are equivalent or better than conventional MCPs. They have low intrinsic background (0.045 events cm-2 sec-1)., high open area ratios (74% for the latest generation of borosilicate substrates), and stable gain during >7 C cm-2 charge extraction after preconditioning (vacuum bake and burn-in). The tube assemblies use a pair of 20 cm × 20 cm ALD MCPs comprised of a borosilicate entrance window, a proximity focused bialkali photocathode, and a strip-line readout anode. The second generation design employs an all glass body with a hot indium seal and a transfer photocathode. We have achieved >20% quantum efficiency and good gain uniformity over the 400 cm2 field of view, spatial resolution of <1 cm and obtained event timing accuracy of close to 100 ps FWHM.

  8. Proton radiation effect on performance of InAs/GaSb complementary barrier infrared detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soibel, Alexander; Rafol, Sir B.; Khoshakhlagh, Arezou

    In this work, we investigated the effect of proton irradiation on the performance of long wavelength infrared InAs/GaSb photodiodes (λ{sub c} = 10.2 μm), based on the complementary barrier infrared detector design. We found that irradiation with 68 MeV protons causes a significant increase of the dark current from j{sub d} = 5 × 10{sup −5} A/cm{sup 2} to j{sub d} = 6 × 10{sup −3} A/cm{sup 2}, at V{sub b} = 0.1 V, T = 80 K and fluence 19.2 × 10{sup 11 }H{sup +}/cm{sup 2}. Analysis of the dark current as a function of temperature and bias showed that the dominant contributor to the dark current in these devices changes from diffusion current to tunneling current after proton irradiation.more » This change in the dark current mechanism can be attributed to the onset of surface leakage current, generated by trap-assisted tunneling processes in proton displacement damage areas located near the device sidewalls.« less

  9. Low-cost superior solid-state symmetric supercapacitors based on hematite nanocrystals.

    PubMed

    Peng, Shaomin; Yu, Lin; Lan, Bang; Sun, Ming; Cheng, Gao; Liao, Shuhuan; Cao, Han; Deng, Yulin

    2016-11-22

    We present a facile method for the fabrication of hematite nanocrystal-carbon cloth (Fe 2 O 3 -CC) composite. Hierarchical manganite is chosen as the sacrificial precursor, that does not contribute to the component of final iron oxide but can be in situ dissolved by the acid produced from the Fe 3+ hydrolysis. This method effectively enhances the specific surface area and conductivity of hematite (Fe 2 O 3 ) by attaching Fe 2 O 3 nanocrystals (around 5 nm) firmly on the surface of carbon fibers. The obtained Fe 2 O 3 -CC can be directly used as a binder-free electrode for a supercapacitor. Interestingly, the composite electrode exhibits synergistic electrochemical capacitance (electrochemical double-layer capacitance and pseudo-capacitance). It manifests a very high areal capacitance of 1.66 F cm -2 (1660 F g -1 ) at 2 mA cm -2 and excellent cycling performance at large current densities (88.6% retention at 30 mA cm -2 after 5000 cycles) in a three-electrode testing system, which is among the best performances reported in the literature. Importantly, when fabricated as a solid-state flexible symmetric supercapacitor it still shows a maximum energy density of 8.74 mW h cm -3 and power density of 253.9 mW cm -3 . Additionally, its good flexibility makes it suitable for portable devices.

  10. Low-cost superior solid-state symmetric supercapacitors based on hematite nanocrystals

    NASA Astrophysics Data System (ADS)

    Peng, Shaomin; Yu, Lin; Lan, Bang; Sun, Ming; Cheng, Gao; Liao, Shuhuan; Cao, Han; Deng, Yulin

    2016-12-01

    We present a facile method for the fabrication of hematite nanocrystal-carbon cloth (Fe2O3-CC) composite. Hierarchical manganite is chosen as the sacrificial precursor, that does not contribute to the component of final iron oxide but can be in situ dissolved by the acid produced from the Fe3+ hydrolysis. This method effectively enhances the specific surface area and conductivity of hematite (Fe2O3) by attaching Fe2O3 nanocrystals (around 5 nm) firmly on the surface of carbon fibers. The obtained Fe2O3-CC can be directly used as a binder-free electrode for a supercapacitor. Interestingly, the composite electrode exhibits synergistic electrochemical capacitance (electrochemical double-layer capacitance and pseudo-capacitance). It manifests a very high areal capacitance of 1.66 F cm-2 (1660 F g-1) at 2 mA cm-2 and excellent cycling performance at large current densities (88.6% retention at 30 mA cm-2 after 5000 cycles) in a three-electrode testing system, which is among the best performances reported in the literature. Importantly, when fabricated as a solid-state flexible symmetric supercapacitor it still shows a maximum energy density of 8.74 mW h cm-3 and power density of 253.9 mW cm-3. Additionally, its good flexibility makes it suitable for portable devices.

  11. Dermal absorption of kerosene components in rats and the influence of its amount and area of exposure.

    PubMed

    Tsujino, Yoshio; Hieda, Yoko; Kimura, Kojiro; Dekio, Satoshi

    2003-04-23

    The influences of amount and area of dermal exposure to kerosene upon the levels of kerosene components in biological samples were examined in vivo and in vitro. Thirty-two rats were randomly divided into four groups and exposed to kerosene through the abdominal skin for 2h. The amounts (soaked in cotton) and area of kerosene exposed were 1 ml/4 cm(2) in Group I, 4 ml/4 cm(2) in Group II, 4 ml/16 cm(2) in Group III and 16 ml/64 cm(2) in Group IV. Before, then 5, 10, 20, 30, 45, 60, 90 and 120 min after exposure, 0.5 ml of blood was collected. Solid tissue samples, including the exposed skin area, were harvested at 120 min. Kerosene components were analyzed by gas chromatography/mass spectrometry. Trimethylbenzens (TMBs) that are easily absorbed kerosene components, appeared at 5-20 min. The time course changes in TMB levels in blood were significantly different between Groups I and II or Groups I and III, and almost identical between Groups II and III. Similar trends were observed in tissue samples at 120 min. High concentrations of aliphatic hydrocarbons (AHCs) were detected in the exposed skin and the AHC levels were dependent on the amount of kerosene exposed per unit area. These results suggest that (1) dermal absorption of kerosene occurs soon after dermal exposure started, (2) absorption of TMBs is influenced by the total amount of kerosene rather than area of exposure, and (3) AHCs remaining in the skin at significant levels are influenced by the amount of kerosene per unit area exposed.

  12. Monitoring spatial variations in soil organic carbon using remote sensing and geographic information systems

    NASA Astrophysics Data System (ADS)

    Jaber, Salahuddin M.

    Soil organic carbon (SOC) sequestration is a component of larger strategies to control the accumulation of greenhouse gases that may be causing global warming. To implement this approach, it is necessary to improve the methods of measuring SOC content. Among these methods are indirect remote sensing and geographic information systems (GIS) techniques that are required to provide non-intrusive, low cost, and spatially continuous information that cover large areas on a repetitive basis. The main goal of this study is to evaluate the effects of using Hyperion hyperspectral data on improving the existing remote sensing and GIS-based methodologies for rapidly, efficiently, and accurately measuring SOC content on farmland. The study area is Big Creek Watershed (BCW) in Southern Illinois. The methodology consists of compiling a GIS database (consisting of remote sensing and soil variables) for 303 composite soil samples collected from representative pixels along the Hyperion coverage area of the watershed. Stepwise procedures were used to calibrate and validate linear multiple regression models where SOC was regarded as the response and the other remote sensing and soil variables as the predictors. Two models were selected. The first was the best all variables model and the second was the best only raster variables model. Map algebra was implemented to extrapolate the best only raster variables model and produce a SOC map for the BGW. This study concluded that Hyperion data marginally improved the predictability of the existing SOC statistical models based on multispectral satellite remote sensing sensors with correlation coefficient of 0.37 and root mean square error of 3.19 metric tons/hectare to a 15-cm depth. The total SOC pool of the study area is about 225,232 metric tons to 15-cm depth. The nonforested wetlands contained the highest SOC density (34.3 metric tons/hectare/15cm) with total SOC content of about 2,003.5 metric tons to 15-cm depth, where croplands had the lowest SOC density (21.6 metric tons/hectare/15cm) with total SOC content of about 44,571.2 metric tons to 15-cm depth.

  13. Carborane-Based Metal-Organic Framework with High Methane and Hydrogen Storage Capacities

    DTIC Science & Technology

    2013-01-01

    guest solvent molecules were removed via supercritical CO2 (see the Supporting Information for activation details),30,31 the samples were further...unique geometry of the carborane unit, NU-135 has a very high volumetric BET surface area of ca. 1900 m2/cm3. CH4, CO2 , and H2 adsorption isotherms...NU-135 has a very high volumetric BET surface area of ca. 1900 m2/cm3. CH4, CO2 , and H2 adsorption isotherms were measured over a broad range of

  14. Effect of Capacitive Radiofrequency on the Fibrosis of Patients with Cellulite

    PubMed Central

    Valentim da Silva, Rodrigo Marcel; Barichello, Priscila Arend; Medeiros, Melyssa Lima; de Mendonça, Waléria Cristina Miranda; Dantas, Jung Siung Camel; Ronzio, Oscar Ariel; Froes, Patricia Meyer

    2013-01-01

    Background. Cellulite is a type of lipodystrophy that develops primarily from an alteration in blood circulation or of the lymphatic system that causes structural changes in subcutaneous adipose tissue, collagen, and adjacent proteoglycans. The radiofrequency devices used for cutaneous applications have shown different physiological treatment effects, but there is controversy about the suitable parameters for this type of treatment. Objectives. The aim of this study was to evaluate the effects of low-temperature radiofrequency to confirm the thinning of the collagen tissue and interlobular septa and consequent improvement of cellulite. Methods. A sample of eight women was used to collect ultrasonographic data with a 12 MHz probe that measured collagen fiber thickness. The Vip Electromedicina (Argentina) device, frequency of 0.55 MHz and active electrode 3.5 cm in diameter (area = 9.61 cm2), was applied to a 10 cm2 region of the gluteal region for 2 minutes per area of active electrode, during 10 biweekly sessions. Results. The Wilcoxon matched paired test was applied using GraphPad InStat 3.01 for Win95-NT software. Pre- and posttreatment mean collagen fiber thickness showed a 24.66% reduction from 1.01 to 0.67 mm. Statistical analysis using the Wilcoxon matched paired test obtained a significant two-tailed P value of 0.0391. Conclusion. It was concluded that the use of more comfortable temperatures favored a reduction in fibrous septum thickness and consequent cellulite improvement, evidenced by the lower degree of severity and decrease in interlobular septal thickness. PMID:24223586

  15. Variability in Effective Radiating Area and Output Power of New Ultrasound Transducers at 3 MHz

    PubMed Central

    Johns, Lennart D; Straub, Stephen J; Howard, Samuel M

    2007-01-01

    Context: Spatial average intensity (SAI) is often used by clinicians to gauge therapeutic ultrasound dosage, yet SAI measures are not directly regulated by US Food and Drug Administration (FDA) standards. Current FDA guidelines permit a possible 50% to 150% minimum to maximum range of SAI values, potentially contributing to variability in clinical outcomes. Objective: To measure clinical values that describe ultrasound transducers and to determine the degree of intramanufacturer and intermanufacturer variability in effective radiating area, power, and SAI when the transducer is functioning at 3 MHz. Design: A descriptive and interferential approach was taken to this quasi-experimental design. Setting: Measurement laboratory. Patients or Other Participants: Sixty-six 5-cm2 ultrasound transducers were purchased from 6 different manufacturers. Intervention(s): All transducers were calibrated and then assessed using standardized measurement techniques; SAI was normalized to account for variability in effective radiating area, resulting in an nSAI. Main Outcome Measure(s): Effective radiating area, power, and nSAI. Results: All manufacturers with the exception of Omnisound (P = .534) showed a difference between the reported and measured effective radiating area values (P < .001). All transducers were within FDA guidelines for power (±20%). Chattanooga (0.85 ± 0.05 W/cm2) had a lower nSAI (P < .05) than all other manufacturers functioning at 3 MHz. Intramanufacturer variability in SAI ranged from 16% to 35%, and intermanufacturer variability ranged from 22% to 61%. Conclusions: Clinicians should consider treatment values of each individual transducer, regardless of the manufacturer. In addition, clinicians should scrutinize the power calibration and recalibration record of the transducer and adjust clinical settings as needed for the desired level of heating. Our data may aid in explaining the reported heating differences among transducers from different manufacturers. Stricter FDA standards regarding effective radiating area and total power are needed, and standards regulating SAI should be established. PMID:17597939

  16. A shape-adaptive thin-film-based approach for 50% high-efficiency energy generation through micro-grating sliding electrification.

    PubMed

    Zhu, Guang; Zhou, Yu Sheng; Bai, Peng; Meng, Xian Song; Jing, Qingshen; Chen, Jun; Wang, Zhong Lin

    2014-06-18

    Effectively harvesting ambient mechanical energy is the key for realizing self-powered and autonomous electronics, which addresses limitations of batteries and thus has tremendous applications in sensor networks, wireless devices, and wearable/implantable electronics, etc. Here, a thin-film-based micro-grating triboelectric nanogenerator (MG-TENG) is developed for high-efficiency power generation through conversion of mechanical energy. The shape-adaptive MG-TENG relies on sliding electrification between complementary micro-sized arrays of linear grating, which offers a unique and straightforward solution in harnessing energy from relative sliding motion between surfaces. Operating at a sliding velocity of 10 m/s, a MG-TENG of 60 cm(2) in overall area, 0.2 cm(3) in volume and 0.6 g in weight can deliver an average output power of 3 W (power density of 50 mW cm(-2) and 15 W cm(-3)) at an overall conversion efficiency of ∼ 50%, making it a sufficient power supply to regular electronics, such as light bulbs. The scalable and cost-effective MG-TENG is practically applicable in not only harvesting various mechanical motions but also possibly power generation at a large scale. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Alaska/Yukon Geoid Improvement by a Data-Driven Stokes's Kernel Modification Approach

    NASA Astrophysics Data System (ADS)

    Li, Xiaopeng; Roman, Daniel R.

    2015-04-01

    Geoid modeling over Alaska of USA and Yukon Canada being a trans-national issue faces a great challenge primarily due to the inhomogeneous surface gravity data (Saleh et al, 2013) and the dynamic geology (Freymueller et al, 2008) as well as its complex geological rheology. Previous study (Roman and Li 2014) used updated satellite models (Bruinsma et al 2013) and newly acquired aerogravity data from the GRAV-D project (Smith 2007) to capture the gravity field changes in the targeting areas primarily in the middle-to-long wavelength. In CONUS, the geoid model was largely improved. However, the precision of the resulted geoid model in Alaska was still in the decimeter level, 19cm at the 32 tide bench marks and 24cm on the 202 GPS/Leveling bench marks that gives a total of 23.8cm at all of these calibrated surface control points, where the datum bias was removed. Conventional kernel modification methods in this area (Li and Wang 2011) had limited effects on improving the precision of the geoid models. To compensate the geoid miss fits, a new Stokes's kernel modification method based on a data-driven technique is presented in this study. First, the method was tested on simulated data sets (Fig. 1), where the geoid errors have been reduced by 2 orders of magnitude (Fig 2). For the real data sets, some iteration steps are required to overcome the rank deficiency problem caused by the limited control data that are irregularly distributed in the target area. For instance, after 3 iterations, the standard deviation dropped about 2.7cm (Fig 3). Modification at other critical degrees can further minimize the geoid model miss fits caused either by the gravity error or the remaining datum error in the control points.

  18. CT-based manual segmentation and evaluation of paranasal sinuses.

    PubMed

    Pirner, S; Tingelhoff, K; Wagner, I; Westphal, R; Rilk, M; Wahl, F M; Bootz, F; Eichhorn, Klaus W G

    2009-04-01

    Manual segmentation of computed tomography (CT) datasets was performed for robot-assisted endoscope movement during functional endoscopic sinus surgery (FESS). Segmented 3D models are needed for the robots' workspace definition. A total of 50 preselected CT datasets were each segmented in 150-200 coronal slices with 24 landmarks being set. Three different colors for segmentation represent diverse risk areas. Extension and volumetric measurements were performed. Three-dimensional reconstruction was generated after segmentation. Manual segmentation took 8-10 h for each CT dataset. The mean volumes were: right maxillary sinus 17.4 cm(3), left side 17.9 cm(3), right frontal sinus 4.2 cm(3), left side 4.0 cm(3), total frontal sinuses 7.9 cm(3), sphenoid sinus right side 5.3 cm(3), left side 5.5 cm(3), total sphenoid sinus volume 11.2 cm(3). Our manually segmented 3D-models present the patient's individual anatomy with a special focus on structures in danger according to the diverse colored risk areas. For safe robot assistance, the high-accuracy models represent an average of the population for anatomical variations, extension and volumetric measurements. They can be used as a database for automatic model-based segmentation. None of the segmentation methods so far described provide risk segmentation. The robot's maximum distance to the segmented border can be adjusted according to the differently colored areas.

  19. Handbook of Sonar Transducer Passive Materials

    DTIC Science & Technology

    1981-10-30

    Water A sorption 570 -19 days 4.3 1.6 (mg/cm ) Water Permeability 38°C 44 (01 10gI 2 0Cm/cm 2 /cm-hr -torr) ൪ . .7- a. Compounding Recipe The gum...materials in sonar transducers I are discussed. Factors in the compounding and processing of elastorneric materials which affect end-product performance~ are...A. Scope of the Handbook ................ B. Problems r.,f General Consideration ............ C. Compounding of Elastomers

  20. Ablation spot area and impulse characteristics of polymers induced by burst irradiation of 1 μm laser pulses

    NASA Astrophysics Data System (ADS)

    Tsuruta, Hisashi; Dondelewski, Oskar; Katagiri, Yusuke; Wang, Bin; Sasoh, Akihiro

    2017-07-01

    The ablation spot area and impulse characteristics of various polymers were experimentally investigated against burst irradiation of Nd: YLF laser pulses with a pulse repetition frequency of 1 kHz, wavelength of 1047 nm, temporal pulse width of 10 ns, and single-pulse fluence of 6.1 J/cm2 to 17.1 J/cm2. The dependences of ablation area on the pulse energy from 0.72 to 7.48 mJ and the number of pulses from 10 pulses to 1000 pulses were investigated. In order to characterize their impulse performance as a function of fluence, which should not depend on ablation material, an effective ablation spot area was defined as that obtained against aluminum, 1050 A, as the reference material. An impulse that resulted from a single burst of 200 pulses was measured with a torsion-type impulse stand. Various impulse dependences on the fluence, which were not readily predicted from the optical properties of the material without ablation, were obtained. By fitting the experimentally measured impulse performance to Phipps and Sinko's model in the vapor regime, the effective absorption coefficient with laser ablation was evaluated, thereby resulting in three to six orders of magnitude larger than that without ablation. Among the polymers examined using polytetrafluoroethylene (PTFE) as the best volume absorbers, the highest momentum coupling coefficient of 66 μNs/J was obtained with an effective absorption coefficient more than six times smaller than that of the other polymers.

  1. Effects of SP6 Acupuncture Point Stimulation on Labor Pain and Duration of Labor

    PubMed Central

    Yesilcicek Calik, Kiymet; Komurcu, Nuran

    2014-01-01

    Background: Acupressure has been used frequently to improve labor, manage labor pain, and shorten delivery time. However, there has been little research-based evidence to support the positive effects of acupressure in the obstetric area and obstetric nursing. Objectives: The aim of this study was to evaluate the effects of SP6 acupressure on labor pain and delivery time in primigravida women in labor. Patients and Methods: The study was conducted at the Trabzon Maternity Hospital in Turkey. Its design was a randomized controlled clinical trial study using a single-blinded method. One hundred (100) primigravida women in labor were randomly assigned to either the SP6 acupressure (n = 50) or control group (n = 50). Acupressure was practiced 35 times in total on the SP6 point of both legs in the SP6 acupressure group; 15 times (during contraction) when cervical dilation was 2-3 cm, 10 times when cervical dilation was 5-6 cm and 10 times at 9-10 cm dilation, while the women in the control group received standard care. Labor pain was measured five times using a structured questionnaire of a subjective labor pain scale (visual analogue scale-VAS) when dilation was 2-3 cm (VAS 2), 5-6 cm (VAS 3) and 8-9 cm (VAS 4) before and after acupressure was applied to the SP6 point (VAS 1), and finally at the early postpartum period (VAS 5). The duration of labor in both groups was measured with a partograph and the length of delivery time was calculated in two stages: from 3 cm cervical dilation to full cervical dilation, and from full cervical dilation to delivery. Results: There were significant differences between the groups in subjective labor pain scores (except VAS 4) (P < 0.001). The duration of the Phase one (3 cm dilatation to full dilatation) and Phase two (full dilatation to birth) in the acupressure group was shorter than the control group (Phase one, 225 min and 320 min, respectively; Phase two, 15 min and 20 min, respectively; both P < 0.001). Conclusions: It was determined that SP6 acupressure was effective in decreasing pain and duration of labor. PMID:25558386

  2. Performance Analysis of Web-Based Ppp Services with DİFFERENT Visibility Conditions

    NASA Astrophysics Data System (ADS)

    Albayrak, M.; Erkaya, H.; Ozludemir, M. T.; Ocalan, T.

    2016-12-01

    GNSS is being used effectively to precise position for many measuring and geodetic purposes at the present time. There is an increasing variety of these systems including the post-processing calculations in terms of number, quality and features and many different techniques are developed to determine position. Precise positioning intend to derive requires user experience and scientific or commercial software with costly license fees. However, in recent years important alternatives to this software that are user friendly and offer free web-based online precise point positioning service have become widely used in geodetic applications. The aim of this study is to test the performance of PPP techniques on ground control points with different visibility conditions. Within this framework, static observations were carried out for three hours a day repeatedly for six days, in YTU Davutpasa Campus on three different ground control points. The locations of these stations were selected by taking into account the impact of natural (trees, etc.) and artificial (buildings, etc.) obstacles. In order to compare the obtained GPS observations with PPP performances, first of all the accurate coordinates of the control points were computed with relative positioning technique in connection with the IGS stations using Bernese v5.0 software. Afterwards, three different web-based positioning services (CSRS-PPP, magicGNSS, GAPS) were used to analyze the GPS observations via PPP technique. To compare all of the obtained results, ITRF2008 datum measurement epoch coordinates were preferred by taking the service result criteria into consideration. In coordinate comparison, for the first station located nearby a building and possibly subjected to multipath effect horizontal discrepancies vary between 2-14.5 cm while vertical differences are between 3.5-16 cm. For the second point located partly in a forestry area, the discrepancies have been obtained as 1.5-8 cm and 2-10 cm for horizontal and vertical components, respectively. For the third point located in an area with no obstacles, 1.5-7 cm horizontal and 1-7 cm vertical differences have been obtained. The results show that the PPP technique could be used effectively in several positioning applications.

  3. Sarcopenia as a predictor of mortality in elderly blunt trauma patients: Comparing the masseter to the psoas using computed tomography.

    PubMed

    Wallace, James D; Calvo, Richard Y; Lewis, Paul R; Brill, Jason B; Shackford, Steven R; Sise, Michael J; Sise, C Beth; Bansal, Vishal

    2017-01-01

    Sarcopenia, or age-related loss of muscle mass, is measurable by computed tomography (CT). In elderly trauma patients, increased mortality is associated with decreased psoas muscle cross-sectional area (P-Area) on abdominal CT. Fall is the leading cause of injury in the elderly, and head CT is more often obtained. Masseter muscle cross-sectional area (M-Area) is readily measured on head CT. Hypothesizing that M-Area is a satisfactory surrogate for P-Area, we compared the two as markers of sarcopenia and increased mortality in elderly trauma patients. All blunt-injured patients aged 65 years or older admitted to our trauma center during 2010 were included. Two-year postdischarge mortality was identified by matching records to county, state, and national death indices. Bilateral M-Area was measured on admission head CT at 2 cm below the zygomatic arch. Bilateral P-Area was measured on abdominal CT at the fourth vertebral body. Average M-Area and P-Area values were calculated for each patient. Cox proportional hazards models evaluated the relationship of M-Area and P-Area with mortality. Model predictive performance was calculated using concordance statistics. Among 487 patients, 357 with M-Area and 226 with P-Area were identified. Females had smaller M-Area (3.43 cm vs 4.18 cm; p < 0.050) and P-Area (6.50 cm vs 10.9 cm; p < 0.050) than males. Masseter muscle cross-sectional area correlated with P-Area (rho, 0.38; p < 0.001). Adjusted Cox regression models revealed decreased survival associated with declining M-Area (hazard ratio, 0.76; 95% confidence interval, 0.60-0.96) and P-Area (hazard ratio, 0.68; 95% confidence interval, 0.46-1.00). Masseter muscle cross-sectional area and P-Area discriminated equally well in best-fit models. In elderly trauma patients, M-Area is an equally valid and more readily available marker of sarcopenia and 2-year mortality than P-Area. Future study should validate M-Area as a metric to identify at-risk patients who may benefit from early intervention. Prognostic study, level III.

  4. TTI CM/AQ evaluation model user`s guide and workshop training materials. Interim research report, September 1993-August 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-08-01

    The TTI CM/AQ Evaluation Model evaluates potential projects based on the following criteria: eligibility, travel impacts, emission impacts, and cost-effectiveness. To compare independent projects within a region during the decision process for CM/AQ funding, each project evaluated with this model is given an overall score based on the project`s effects for the criteria listed above. Training workshops were held by TTI in the first quarter of 1995 to teach metropolitan planning organization, state department of transportation, and regional air quality organization staff how to use this model. Basics of sketch-planning applications were also taught. The DRCOG and TTI CM/AQ Evaluationmore » Models represent significant steps toward the development of analytical methodologies for selecting projects for CM/AQ funding. Because the needs of nonattainment and attainment areas change over time, this model is particularly useful as key evaluation criteria can be modified to reflect the changing needs of a metropolitan area.« less

  5. Large area, surface discharge pumped, vacuum ultraviolet light source

    DOEpatents

    Sze, Robert C.; Quigley, Gerard P.

    1996-01-01

    Large area, surface discharge pumped, vacuum ultraviolet (VUV) light source. A contamination-free VUV light source having a 225 cm.sup.2 emission area in the 240-340 nm region of the electromagnetic spectrum with an average output power in this band of about 2 J/cm.sup.2 at a wall-plug efficiency of approximately 5% is described. Only ceramics and metal parts are employed in this surface discharge source. Because of the contamination-free, high photon energy and flux, and short pulse characteristics of the source, it is suitable for semiconductor and flat panel display material processing.

  6. Suppressing the Coffee-Ring Effect in Semitransparent MnO2 Film for a High-Performance Solar-Powered Energy Storage Window.

    PubMed

    Jin, Huanyu; Qian, Jiasheng; Zhou, Limin; Yuan, Jikang; Huang, Haitao; Wang, Yu; Tang, Wing Man; Chan, Helen Lai Wa

    2016-04-13

    We introduce a simple and effective method to deposit a highly uniform and semitransparent MnO2 film without coffee-ring effect (CRE) by adding ethanol into MnO2 ink for transparent capacitive energy storage devices. By carefully controlling the amount of ethanol added in the MnO2 droplet, we could significantly reduce the CRE and thus improve the film uniformity. The electrochemical properties of supercapacitor (SC) devices using semitransparent MnO2 film electrodes with or without CRE were measured and compared. The SC device without CRE shows a superior capacitance, high rate capability, and lower contact resistance. The CRE-free device could achieve a considerable volumetric capacitance of 112.2 F cm(-3), resulting in a high volumetric energy density and power density of 10 mWh cm(-3) and 8.6 W cm(-3), respectively. For practical consideration, both flexible SC and large-area rigid SC devices were fabricated to demonstrate their potential for flexible transparent electronic application and capacitive energy-storage window application. Moreover, a solar-powered energy storage window which consists of a commercial solar cell and our studied semitransparent MnO2-film-based SCs was assembled. These SCs could be charged by the solar cell and light up a light emitting diode (LED), demonstrating their potential for self-powered systems and energy-efficient buildings.

  7. Effect of Propolis on Experimental Cutaneous Wound Healing in Dogs

    PubMed Central

    2015-01-01

    This study evaluates clinically the effect of propolis paste on healing of cutaneous wound in dogs. Under general anesthesia and complete aseptic conditions, two full thickness skin wounds (3 cm diameter) were created in each side of the chest in five dogs, one dorsal and one ventral, with 10 cm between them. These wounds were randomly allocated into two groups, control group (10 wounds) and propolis group (10 wounds). Both groups were represented in each dog. The wounds were cleaned with normal saline solution and dressed with macrogol ointment in control group and propolis paste in propolis group, twice daily till complete wound healing. Measurement of the wound area (cm2) was monitored planimetrically at 0, 7, 14, 21, 28, and 35 days after injury. The data were analyzed statistically. The results revealed a significant reduction in the wound surface area in the propolis group after 14 and 21 days compared to control group. The wound reepithelization, contraction, and total wound healing were faster in propolis group than in control group during five weeks of study. In conclusion, propolis paste has a positive impact on cutaneous wound healing and it may be suggested for treating various types of wounds in animals. PMID:26783495

  8. [Signal loss in magnetic resonance imaging caused by intraoral anchored dental magnetic materials].

    PubMed

    Blankenstein, F H; Truong, B; Thomas, A; Schröder, R J; Naumann, M

    2006-08-01

    To measure the maximum extent of the signal loss areas in the center of the susceptibility artifacts generated by ferromagnetic dental magnet attachments using three different sequences in the 1.5 and 3.0 Tesla MRI. Five different pieces of standard dental magnet attachments with volumes of 6.5 to 31.4 mm(3) were used: a NdFeB magnet with an open magnetic field, a NdFeB magnet with a closed magnetic field, a SmCo magnet with an open magnetic field, a stainless steel keeper (AUM-20) and a PdCo piece. The attachments were placed between two cylindrical phantoms and examined in 1.5 and 3.0 Tesla MRI using gradient echo and T1- and T2-weighted spin echoes. We measured the maximum extent of the generated signal loss areas parallel and perpendicular to the direction of B (O). In gradient echoes the artifacts were substantially larger and symmetrically adjusted around the object. The areas with total signal loss were mushroom-like with a maximum extent of 7.4 to 9.7 cm parallel to the direction of B (O) and 6.7 to 7.4 cm perpendicular to B (O). In spin echoes the signal loss areas were obviously smaller, but not centered. The maximum values ranged between 4.9 and 7.2 cm (parallel B (O)) and 3.6 and 7.0 cm (perpendicular B (O)). The different ferromagnetic attachments had no clinically relevant influence on the signal loss neither in 1.5 T nor 3.0 T MRI. Ferromagnetic materials used in dentistry are not intraorally standardized. To ensure, that the area of interest is not affected by the described artifacts, the maximum extent of the signal loss area should be assumed: a radius of up to 7 cm in 1.5 and 3.0 T MRI by T1 and T2 sequences, and a radius of up to 10 cm in T2* sequences. To decide whether magnet attachments have to be removed before MR imaging, physicians should consider both the intact retention of the keepers and the safety distance between the ferromagnetic objects and the area of interest.

  9. Blue Light Phototherapy Kills Methycillin Resistant Staphylococcus Aureus (MRSA)

    NASA Astrophysics Data System (ADS)

    Enwemeka, Chukuka S.; Williams, Debora; Enwemeka, Sombiri K.; Hollosi, Steve; Yens, David

    2010-05-01

    Background: Methycillin resistant staphylococcus aureus (MRSA) bacteria continue to defy most available antibiotics. As a result infections with MRSA remain a growing public health concern. As a paradigm shift and a significant departure from the on-going trend to develop stronger drug-based therapies, we studied the effect of 405 nm and 470 nm wavelengths of blue light on two strains of MRSA—US-300 strain of CA-MRSA and the IS853 strain of HA-MRSA—in vitro. Methods: We cultured and plated each strain, following which bacteria colonies were irradiated with 0, 1, 3, 5, 7, 9, 11, 13, 15, 17, 19, 25, 30, 35, 40, 45, 50, 55, or 60 Jcm-2 energy densities—just once. Specimens were incubated at 35° C for 24 h. Then, digital images obtained were quantified to obtain colony counts and the aggregate area occupied by bacteria colonies. Results: Each wavelength produced a statistically significant dose-dependent reduction in both the number and the aggregate area of colonies formed by each bacteria strain (P<0.001). Maximum eradication of the US-300 (92.1%) and the IS-853 colonies (93.5%) was achieved within 10 minutes of irradiation with each wavelength. The longer the irradiation the more bacteria were eradicated. However, the effect was non-linear as increases of energy densities between 1.0 and 15 J cm-2 resulted in more bacteria death than similar increases between 15 J cm-2 and 60 J cm-2. Conclusion: At low doses, blue light photo-destroys HA-MRSA and CA-MRSA in vitro; raising the prospect that phototherapy may be an effective clinical tool in the on-going effort to stem MRSA infections.

  10. Land management effects on soil carbon in olive groves of Mediterranean areas

    NASA Astrophysics Data System (ADS)

    Fernández-Romero, Maria Luisa; Parras-Alcántara, Luis; Lozano-García, Beatriz; Clark, Joanna; Collins, Chris

    2015-04-01

    The study analysed soil organic carbon (SOC) and hot-water extractable carbon (HWC) in an agricultural Mediterranean area of Southern Spain under different land management: Conventional tillage (CT); Conventional tillage with the addition of oil mill waste, also known as alperujo (A); Conventional tillage with the addition of oil mill waste olive leaves (L); No tillage with chipped pruned branches (NT1); and No tillage with chipped pruned branches and weeds (NT2). SOC values in CT, A, NT1 and NT2 decreased with depth. In L, SOC also decreased with depth, although there was an increase of 89% from the first (0-10 cm) to the second horizon (10-16 cm). Total SOC stock (considering the entire soil profile) was very similar under A (101.9 Mg ha-1), CT (101.7 Mg ha-1), NT1 (105.8 Mg ha-1) and NT2 (111.3 Mg ha-1). However, SOC under L was significantly higher (p

  11. Effects of "short" photoperiods on seedling growth of Pinus brutia.

    PubMed

    Iakovoglou, V; Radoglou, K; Kostopoulou, P; Dini-Papanastasi, O

    2012-03-01

    This study investigated how nurseries could benefit by inducing "short" photoperiods as low as 4 hr to produce "better" seedlings characterized by more vigorous roots; a substantial feature to overcome transplanting stress. The carryover effect of the photoperiod was also investigated on seedlings that grew for 30 days more underthe consistent 14 hr photoperiod. Seedlings of Pinus brutia were subjected to 4, 6, 8 and 14 hr photoperiod for 3 week. Fifteen seedlings were used to evaluate the leaf area, the root and shoot dry weight and their ratio. Six and sixteen seedlings were used to evaluate the shoot electrolyte leakage and the root growth potential, respectively. Based on the results, the 6 and 8 hr photoperiod indicated greater root allocation (4.8 and 4.9 mg, respectively) and chlorophyll content (3.7 and 4.4, respectively). They also indicated greater leaf area values (3.3 and 3.5 cm2, respectively) along with the 14 hr (3.4 cm2). The photoperiod effect continued even after seedlings were subjected at consistent photoperiod. Overall, "short" photoperiods could provide "better" P. brutia seedlings to accommodate immediate massive reforestation and afforestation needs.

  12. Affective valence, stimulus attributes, and P300: color vs. black/white and normal vs. scrambled images.

    PubMed

    Cano, Maya E; Class, Quetzal A; Polich, John

    2009-01-01

    Pictures from the International Affective Picture System (IAPS) were selected to manipulate affective valence (unpleasant, neutral, pleasant) while keeping arousal level the same. The pictures were presented in an oddball paradigm, with a visual pattern used as the standard stimulus. Subjects pressed a button whenever a target was detected. Experiment 1 presented normal pictures in color and black/white. Control stimuli were constructed for both the color and black/white conditions by randomly rearranging 1 cm square fragments of each original picture to produce a "scrambled" image. Experiment 2 presented the same normal color pictures with large, medium, and small scrambled condition (2, 1, and 0.5 cm squares). The P300 event-related brain potential demonstrated larger amplitudes over frontal areas for positive compared to negative or neutral images for normal color pictures in both experiments. Attenuated and nonsignificant valence effects were obtained for black/white images. Scrambled stimuli in each study yielded no valence effects but demonstrated typical P300 topography that increased from frontal to parietal areas. The findings suggest that P300 amplitude is sensitive to affective picture valence in the absence of stimulus arousal differences, and that stimulus color contributes to ERP valence effects.

  13. N,N-diethyl phenylacetamide (DEPA): A safe and effective repellent for personal protection against hematophagous arthropods.

    PubMed

    Kalyanasundaram, Muthuswami; Mathew, Nisha

    2006-05-01

    Repellents play an important role in protecting humans from the bites of insect pests. An effective and safe repellent will be useful in reducing human-vector contact and thereby help in the interruption of vector borne disease transmission. Because of the unavailability of m-toluic acid in India for the manufacture of N,N-diethyl m-toluamide (DEET), there is a need to develop an alternate effective and safe insect repellent. In total, 120 substituted amides were synthesized and tested for repellency at 1.0 mg/cm2 under laboratory conditions. Among these amides, N,N-diethyl phenylacetamide (DEPA), applied at 1.0 mg/cm2 in different oil bases, was found to exhibit promising repellency (6-8 h) in the laboratory when tested against Aedes aegypti (L.) The repellent DEPA was evaluated on army personnel in comparison with dimethylphthalate (DMP) and DEET against mosquitoes, black flies, and land leeches under field condition in the North-East Frontier area of India. Both DEPA and DEET displayed broad-spectrum repellency. DEPA was more effective than DMP against all test organisms. However, no significant difference was noticed between DEPA and DEET for repellency at 0.25 and 0.5 mg/cm2 against black flies and mosquitoes. DMP was the least effective among the three compounds in the field studies. The relative potency of DEPA in comparison with DEET and DMP for repellency against Phlebotomine sand flies also was determined. At 0.1 mg/cm2, both DEPA and DEET were found to be equally effective with a protection time from 4.37 +/- 0.08 to 4.45 +/- 0.15 h. Both compounds were significantly more effective than DMP. At 0.2 mg/cm2, DEPA and DEET provided protection times of 6.52 +/- 0.08 and 7.15 +/- 0.15 h, respectively. DEPA was formulated into a vanishing cream, a pharmacologically safe polymer-based liquid, and a liposphere lotion. The vanishing cream and the two-polymer liquid formulations enhanced protection times from 4.4 to 6.5 and 7.13 h, respectively, compared with an alcohol solution applied at 0.5 mg/cm2 on the forearm of human volunteers. Formulations of DEPA and DEET applied at 0.5 mg/cm2 on rabbits exposed to Ae. aegypti enhanced protection times compared with an alcohol solution and the liposphere lotion from 4.0 to 6.0 h and 4.0 to 5.0 h, respectively. Comparison of mean protection times of DEET and DEPA applied at a rate of 0.3 mg/cm2 to human volunteers exposed to Cx. quinque-fasciatus under field conditions indicated that the lotion formulations of DEET and DEPA provided significantly (Duncan's multiple-range test, P < 0.05) higher protection times than did alcohol solutions. Toxicological studies revealed that DEPA is safe.

  14. Sediment texture and metal contamination in the Venice Lagoon (Italy): A snapshot before the installation of the MOSE system

    NASA Astrophysics Data System (ADS)

    Zonta, Roberto; Botter, Margherita; Cassin, Daniele; Bellucci, Luca Giorgio; Pini, Roberto; Dominik, Janusz

    2018-05-01

    Sediments of the Venice Lagoon down to 50 cm depth were investigated to assess sediment texture and metal contamination status, before the construction and activation of the MOSE system, which is intended to prevent the periodical flood events affecting the lagoon and the city of Venice. 380 cores were collected in shallow-water areas of the lagoon, and analysed along their vertical profile to determine grain-size distribution and concentrations of some major and trace elements (Al, As, Cr, Cu, Fe, Hg, Mn, Ni, Pb and Zn), total carbon and organic carbon. Radionuclide analyses (137Cs, 210Pb) were performed on 15 cores in an attempt to establish sediment chronology and determine radionuclide inventories in erosional and depositional areas. On the whole-lagoon scale, strong depletion of particles <31 μm in diameter (from medium silt to clay fractions) was observed in sediments down to 10 cm depth in comparison to deeper layers. This depletion characterised both erosional and depositional areas, and may be caused by increased water dynamics and resuspension of sediment due to anthropogenic activities. The apparent sediment accumulation rate determined with 210Pbxs in depositional areas was estimated at 0.2-0.4 cm y-1. In the majority of cores, 210Pbxs inventories were lower than expected from atmospheric fallout, suggesting its export along with fine particles. The different sediment characteristics in terms of grain-size distribution and organic carbon content observed in the upper layer with respect to the deeper ones reflect the modification of the sedimentary balance in recent years. The loss of fine particles, even from sediments in depositional areas of the northern part of the lagoon, may herald changes in local sediment texture leading to a further depletion of morphodiversity, which in turn may lead to the reduction or loss of important lagoon habitats. On the whole-lagoon scale, the prevalently lithogenic elements (Al, As, Cr, Fe, Mn, Ni) decreased towards the top of the cores, reflecting the depletion of fine particles in the upper sediment layer due to winnowing in non-confined lagoon areas. In contrast, partly anthropogenic elements (Cu, Hg, Pb, Zn) increased up to the subsurface sediment layers (5-10 and/or 10-20 cm) as an effect of increasing pollutant inputs until a certain time in the past. Enrichment Factors (EF) were calculated from 9 cores, comparing concentrations in the "pre-industrial" (>100 years ago) and recent (surface layer, 0-5 cm) sediments. The mostly lithogenic elements were not enriched (EF ˜ 1), whereas the partly anthropogenic elements showed slight (Cu and Pb, EF ˜ 1.2) to significant (Hg and Zn, EF ˜ 2) enrichment. The shallow waters on the landward side (particularly close to freshwater inputs), the area nearby the industrial district of Porto Marghera and a small zone adjacent to the city of Chioggia were identified as the main pollutant accumulation sites. Mercury was the only element potentially harmful for aquatic life. Its concentration in the biologically active surface sediment layer (0-5 cm) exceeded the NOAA Effects Range-Median (ERM) value in 27% of samples, corresponding to 20% of the shallow-water surface area. The collected data set represents a valuable reference for monitoring the impact of the construction and operation of the MOSE system on the sediment features of the Venice Lagoon.

  15. Visual acuity measured with luminance-modulated and contrast-modulated noise letter stimuli in young adults and adults above 50 years old

    PubMed Central

    Woi, Pui Juan; Kaur, Sharanjeet; Waugh, Sarah J.; Hairol, Mohd Izzuddin

    2016-01-01

    The human visual system is sensitive in detecting objects that have different luminance level from their background, known as first-order or luminance-modulated (LM) stimuli. We are also able to detect objects that have the same mean luminance as their background, only differing in contrast (or other attributes). Such objects are known as second-order or contrast-modulated (CM), stimuli. CM stimuli are thought to be processed in higher visual areas compared to LM stimuli, and may be more susceptible to ageing. We compared visual acuities (VA) of five healthy older adults (54.0±1.83 years old) and five healthy younger adults (25.4±1.29 years old) with LM and CM letters under monocular and binocular viewing. For monocular viewing, age had no effect on VA [F(1, 8)= 2.50, p> 0.05]. However, there was a significant main effect of age on VA under binocular viewing [F(1, 8)= 5.67, p< 0.05].  Binocular VA with CM letters in younger adults was approximately two lines better than that in older adults. For LM, binocular summation ratios were similar for older (1.16±0.21) and younger (1.15±0.06) adults. For CM, younger adults had higher binocular summation ratio (1.39±0.08) compared to older adults (1.12±0.09). Binocular viewing improved VA with LM letters for both groups similarly. However, in older adults, binocular viewing did not improve VA with CM letters as much as in younger adults. This could reflect a decline of higher visual areas due to ageing process, most likely higher than V1, which may be missed if measured with luminance-based stimuli alone. PMID:28184281

  16. Study on growth of large area mercuric iodide polycrystalline film and its x-ray imaging

    NASA Astrophysics Data System (ADS)

    Xu, Gang; Guo, Yanfei; Xi, Zengzhe; Gu, Zhi; Zhang, Lan; Yu, Wentao; Ma, Xuming; Li, Bo

    2014-11-01

    Tetragonal mercuric iodide, as a group of wide band gap semiconductors, has been widely investigation during most of the last half-century, applied on room-temperature X-ray and gamma-ray spectrometers. Up to the present, Mercuric iodide (HgI2) is still thought to be one of the most outstanding vitality semiconductor materials because of its wide band gap, for which the device was required to be high resistivity, high atomic number, adequate mechanical strength, long carrier lifetimes and high mobility-lifetime produces. Now, HgI2 polycrystalline films are being developed as a new detector technology for digital x-ray imaging. In this research, HgI2 polycrystalline films with different surface areas of 1 and 36 cm2 were grown by vapor sublimation method within a self-design growth furnace. XRD, SEM and J-V analysis were used to characterize the properties of these as-grown films. The results of XRD show that the ratio of (001) / (hkl) on all as-grown films is amount to be 90% for the area of 1 cm2 films. Grain size of 1 cm2 films was measured to be 120-150 μm. Their electrical resistivity were also determined to be about 1011 Ω·cm operated at the bias voltage of ~100 V by I-V characteristic measurement. Utilizing the polycrystalline film with the area of 36 cm2 deposited on TFT, we then prepared the direct image detector after capsulation for non-corrosive steel screw imaging. The results indicated that profile of screw was distinctly exhibited in digital x-ray imaging systems.

  17. The chemical and catalytic properties of nanocrystalline metal oxides prepared through modified sol-gel synthesis

    NASA Astrophysics Data System (ADS)

    Carnes, Corrie Leigh

    The goal of this research was to synthesize, characterize and study the chemical properties of nanocrystalline metal oxides. Nanocrystalline (NC) ZnO, CuO, NiO, Al2O3, and the binary Al2O 3/MgO and ZnO/CuO were prepared through modified sol gel methods. These NC metal oxides were studied in comparison to the commercial (CM) metal oxides. The samples were characterized by XRD, TGA, FTIR, BET, and TEM. The NC samples were all accompanied by a significant increase in surface area and decrease in crystallite size. Several chemical reactions were studied to compare the NC samples to the CM samples. One of the reactions involved a high temperature reaction between carbon tetrachloride and the oxide to form carbon dioxide and the corresponding metal chloride. A similar high temperature reaction was conducted between the metal oxide and hydrogen sulfide to form water and the corresponding metal sulfide. A room temperature gas phase adsorption was studied where SO2 was adsorbed onto the oxide. A liquid phase adsorption conducted at room temperature was the destructive adsorption of paraoxon (a toxic insecticide). In all reactions the NC samples exhibited greater activity, destroying or adsorbing a larger amount of the toxins compared to the CM samples. To better study surface area effects catalytic reactions were also studied. The catalysis of methanol was studied over the nanocrystalline ZnO, CuO, NiO, and ZnO/CuO samples in comparison to their commercial counterparts. In most cases the NC samples proved to be more active catalysts, having higher percent conversions and turnover numbers. A second catalytic reaction was also studied, this reaction was investigated to look at the support effects. The catalysis of cyclopropane to propane was studied over Pt and Co catalysts. These catalysts were supported onto NC and CM alumina by impregnation. By observing differences in the catalytic behavior, support effects have become apparent.

  18. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    PubMed

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  19. Comparison of two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam.

    PubMed

    Whitaker, Thomas J; Beltran, Chris; Tryggestad, Erik; Bues, Martin; Kruse, Jon J; Remmes, Nicholas B; Tasson, Alexandria; Herman, Michael G

    2014-08-01

    Delayed charge is a small amount of charge that is delivered to the patient after the planned irradiation is halted, which may degrade the quality of the treatment by delivering unwarranted dose to the patient. This study compares two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam. The delivery of several treatment plans was simulated by applying a normally distributed value of delayed charge, with a mean of 0.001(SD 0.00025) MU, to each spot. Two correction methods were used to account for the delayed charge. Method one (CM1), which is in active clinical use, accounts for the delayed charge by adjusting the MU of the current spot based on the cumulative MU. Method two (CM2) in addition reduces the planned MU by a predicted value. Every fraction of a treatment was simulated using each method and then recomputed in the treatment planning system. The dose difference between the original plan and the sum of the simulated fractions was evaluated. Both methods were tested in a water phantom with a single beam and simple target geometry. Two separate phantom tests were performed. In one test the dose per fraction was varied from 0.5 to 2 Gy using 25 fractions per plan. In the other test the number fractions were varied from 1 to 25, using 2 Gy per fraction. Three patient plans were used to determine the effect of delayed charge on the delivered dose under realistic clinical conditions. The order of spot delivery using CM1 was investigated by randomly selecting the starting spot for each layer, and by alternating per layer the starting spot from first to last. Only discrete spot scanning was considered in this study. Using the phantom setup and varying the dose per fraction, the maximum dose difference for each plan of 25 fractions was 0.37-0.39 Gy and 0.03-0.05 Gy for CM1 and CM2, respectively. While varying the total number of fractions, the maximum dose difference increased at a rate of 0.015 Gy and 0.0018 Gy per fraction for CM1 and CM2, respectively. For CM1, the largest dose difference was found at the location of the first spot in each energy layer, whereas for CM2 the difference in dose was small and showed no dependence on location. For CM1, all of the fields in the patient plans had an area where their excess dose overlapped. No such correlation was found when using CM2. Randomly selecting the starting spot reduces the maximum dose difference from 0.708 to 0.15 Gy. Alternating between first and last spot reduces the maximum dose difference from 0.708 to 0.37 Gy. In the patient plans the excess dose scaled linearly at 0.014 Gy per field per fraction for CM1 and standard delivery order. The predictive model CM2 is superior to a cumulative irradiation model CM1 for minimizing the effects of delayed charge, particularly when considering maximal dose discrepancies and the potential for unplanned hot-spots. This study shows that the dose discrepancy potentially scales at 0.014 Gy per field per fraction for CM1.

  20. [Soil seed bank research in China: present status, progress and challenges].

    PubMed

    Shen, You-Xin; Zhao, Chun-Yan

    2009-02-01

    By searching soil seed bank (SSB) papers from http://www.cqvip.com (1989-2006) and Web of Science (1985-2006), the information on SSB density, species richness, and research methods were summarized according to the 29 classified vegetation types in Vegetation of China. In total, the data of 238 sites with 14 vegetation types were collected. The results showed that the research methods adopted by different researchers and the obtained data of SSB density and species richness varied greatly. In related researches, sampling work was mostly conducted in April and October, sampling plot number ranged from 2 to 480, plot area ranged from 78 cm2 to 10,000 cm2, with 10 cm x 10 cm and 20 cm x 20 cm as most common, and total sampling area ranged from 600 cm2 to 500,000 cm2, with the most being 1,000-10,000 cm2. SSB density varied from 8 ind x m(-2) (desert) to 65,355 ind x m(-2) (tropical rain forest), and species richness varied from 1 (secondary bare alkali-saline patch in temperate) to 74 (tropical seasonal rain forest) per site. SSB density and species richness were higher in tropical rain forest and seasonal rain forest than in temperate coniferous forest, and in manmade forest than in agricultural land or barren land. Grassland, desert, and meadow had smaller species richness. In future, the SSB research should be extended both in scope and in deepness, with the focus on the long term research and strategy research of some important ecosystems, and the research should be incorporated into vegetation regeneration and restoration studies. The related methodological research should be also emphasized in the future.

  1. Efficacy of adhesive strips to reduce postoperative periorbital edema and ecchymosis following rhinoplasty

    PubMed

    Tatar, Sedat; Bulam, Mehmet Hakan; Özmen, Selahattin

    2018-02-23

    Background/aim: Periorbital edema and ecchymosis may develop following rhinoplasty. The aim of this study was to assess the efficacy of adhesive strip application on the upper and lower eyelids to reduce postoperative edema and ecchymosis following rhinoplasty. Materials and methods: The eyelids of one side were randomly selected, and an adhesive strip of standard size and number was applied at the end of the operation. The strips were removed at postoperative day 3; photos of the eyes were taken at days 3 and 7. Edema and ecchymosis were graded on a scale from 1 to 4. The ecchymosis areas on the lower and upper eyelids were measured and compared in square centimeters. Results: The mean ecchymosis area of the lower eyelid on the side of the adhesive strip and on the side without the strip was 1.63 cm2 and 3.32 cm2 in the early period, respectively. It was 1.15 cm2 on the upper eyelid on the side of the adhesive strip, and 1.87 cm2 on the side without the strip. It was 0.224 cm2 on the side of the adhesive strip, and 0.498 cm2 on the side without the adhesive strip in the late period. Conclusion: Applying adhesive strips reduces periorbital edema and ecchymosis.

  2. The effect of Nafion membrane thickness on performance of all tungsten-cobalt heteropoly acid redox flow battery

    NASA Astrophysics Data System (ADS)

    Liu, Yiyang; Wang, Haining; Xiang, Yan; Lu, Shanfu

    2018-07-01

    Recently, we have reported a new all tungsto-cobalt heteropoly acid redox flow battery (all H6[CoW12O40] RFB) with high coulombic efficiency. Because of the relatively large ion size and high negative charge, the tungsto-cobalt heteropoly acid anion is difficult to cross Nafion membrane, which makes it possible to employ thinner Nafion membrane in all H6[CoW12O40] RFB. In this study, three types of Nafion membranes with different thickness, namely, N212 (50 μm), N211 (25 μm), and N-17 (home-made, 17 μm) are used as polymer electrolyte to investigate its effects on the performance of all H6[CoW12O40] RFB. The ion permeability increases while the area specific resistanceas decreases as reducing the membrane thickness. As a result, the RFB with N211 membrane exhibits best comprehensive performance, which exhibites the energy efficiency of 88.6% at current density of 0.10 A cm-2 and the power density of 0.56 W cm-2 at 0.60 A cm-2. Moreover, the battery delivers impressive cycling performance of 100 cycles with an average coulombic efficiency of 99.4%, energy efficiency of 80.0%, and capacity retention of 99.98% per cycle at current density of 0.20 A cm-2.

  3. Industrial ion source technology

    NASA Technical Reports Server (NTRS)

    Kaufman, H. R.; Robinson, R. S.

    1979-01-01

    In reactive ion etching of Si, varying amounts of O2 were added to the CF4 background. The experimental results indicated an etch rate less than that for Ar up to an O2 partial pressure of about .00006 Torr. Above this O2 pressure, the etch rate with CF4 exceeded that with Ar alone. For comparison the random arrival rate of O2 was approximately equal to the ion arrival rate at a partial pressure of about .00002 Torr. There were also ion source and ion pressure gauge maintenance problems as a result of the use of CF4. Large scale (4 sq cm) texturing of Si was accomplished using both Cu and stainless steel seed. The most effective seeding method for this texturing was to surround the sample with large inclined planes. Designing, fabricating, and testing a 200 sq cm rectangular beam ion source was emphasized. The design current density was 6 mA/sq cm with 500 eV argon ions, although power supply limitations permitted operation to only 2 mA/sq cm. The use of multiple rectangular beam ion sources for continuous processing of wider areas than would be possible with a single source was also studied. In all cases investigated, the most uniform coverage was obtained with 0 to 2 cm beam overlay. The maximum departure from uniform processing at optimum beam overlap was found to be +15%.

  4. Effect of electrode intrusion on pressure drop and electrochemical performance of an all-vanadium redox flow battery

    NASA Astrophysics Data System (ADS)

    Kumar, S.; Jayanti, S.

    2017-08-01

    In this paper, we present a study of the effect of electrode intrusion into the flow channel in an all-vanadium redox flow battery. Permeability, pressure drop and electrochemical performance have been measured in a cell with active area 100 cm2and 414 cm2 fitted with a carbon felt electrode of thickness of 3, 6 or 9 mm compressed to 1.5, 2.5 or 4 mm, respectively, during assembly. Results show that the pressure drop is significantly higher than what can be expected in the thick electrode case while its electrochemical performance is lower. Detailed flow analysis using computational fluid dynamics simulations in two different flow fields shows that both these results can be attributed to electrode intrusion into the flow channel leading to increased resistance to electrolyte flow through the electrode. A correlation is proposed to evaluate electrode intrusion depth as a function of compression.

  5. The pro‐inflammatory effects of low‐toxicity low‐solubility particles, nanoparticles and fine particles, on epithelial cells in vitro: the role of surface area

    PubMed Central

    Monteiller, Claire; Tran, Lang; MacNee, William; Faux, Steve; Jones, Alan; Miller, Brian; Donaldson, Ken

    2007-01-01

    Objective Rats exposed to high airborne mass concentrations of low‐solubility low‐toxicity particles (LSLTP) have been reported to develop lung disease such as fibrosis and lung cancer. These particles are regulated on a mass basis in occupational settings, but mass might not be the appropriate metric as animal studies have shown that nanoparticles (ultrafine particles) produce a stronger adverse effect than fine particles when delivered on an equal mass basis. Methods This study investigated whether the surface area is a better descriptor than mass of LSLTP of their ability to stimulate pro‐inflammatory responses in vitro. In a human alveolar epithelial type II‐like cell line, A549, we measured interleukin (IL)‐8 mRNA, IL8 protein release and glutathione (GSH) depletion as markers of pro‐inflammatory effects and oxidative stress after treatment with a range of LSLTP (fine and nanoparticles) and DQ12 quartz, a particle with a highly reactive surface. Results In all the assays, nanoparticle preparations of titanium dioxide (TiO2‐np) and of carbon black (CB‐np) produced much stronger pro‐inflammatory responses than the same mass dose of fine TiO2 and CB. The results of the GSH assay confirmed that oxidative stress was involved in the response to all the particles, and two ultra‐fine metal dusts (cobalt and nickel) produced GSH depletion similar to TiO2‐np, for similar surface‐area dose. As expected, DQ12 quartz was more inflammatory than the low toxicity dusts, on both a mass and surface‐area basis. Conclusion Dose–response relationships observed in the in vitro assays appeared to be directly comparable with dose–response relationships in vivo when the doses were similarly standardised. Both sets of data suggested a threshold in dose measured as surface area of particles relative to the surface area of the exposed cells, at around 1–10 cm2/cm2. These findings are consistent with the hypothesis that surface area is a more appropriate dose metric than mass for the pro‐inflammatory effects of LSLTP in vitro and in vivo, and consequently that the high surface area of nanoparticles is a key factor in their inflammogenicity. PMID:17409182

  6. In vitro toxicity of photodynamic antimicrobial chemotherapy on human keratinocytes proliferation.

    PubMed

    Migliario, Mario; Rizzi, Manuela; Rocchetti, Vincenzo; Cannas, Mario; Renò, Filippo

    2013-02-01

    This in vitro experimental study has been designed to assess the effects of photodynamic antimicrobial chemotherapy (PACT) on human keratinocytes proliferation. Human keratinocytes (HaCaT) monolayers (∼0.5 cm(2)) have been irradiated with 635 nm red laser light with a fluence of 82.5 or 112.5 J/cm(2) in the absence or presence of toluidine (TB). Cell proliferation, monolayer area coverage, cytokeratin 5 (K5) and filaggrin (Fil) expression, and metalloproteinase (MMP)-2 and MMP-9 activity were measured after 72 h from laser irradiation. HaCaT proliferation was reduced by TB staining. Cell exposure to both low- and high-fluence laser irradiation in both presence and absence of TB staining reduced their proliferation and monolayer area extension. Moreover both laser treatments were able to reduce K5 and Fil expression and MMP-9 production in keratinocytes not treated with TB. These data indicate that PACT could exert toxic effects on normal proliferating keratinocytes present around parodontal pockets. The observed reduced cell proliferation along with a reduced production of enzymes involved in wound healing could alter the clinical outcome of the patients treated with PACT.

  7. Ecological risk assessment of the Assaluyeh and Bassatin estuaries (northern Persian Gulf) using sediment quality indices

    NASA Astrophysics Data System (ADS)

    Davoodi, Hamid; Gharibreza, Mohammadreza; Negarestan, Hossein; Mortazavi, Mohammad Sedigh; Lak, Razieh

    2017-06-01

    The Assaluyeh and Bassatin estuaries are located in Nayband Bay in the northern Persian Gulf, which faces long-term contamination and ecological risks. The research objectives of this study were designed to assess the ecological risks for human health and aquatic life and to evaluate impacts on environmental changes. Accordingly, an index analysis approach (using the contamination factor Cf, contamination degree Cd, potential ecological risk factor for individual metals Er, and potential ecological risk index for the basin, RI) in conjunction with the enrichment factor (Ef) and sediment quality levels (comprised of the threshold effect level, TEL, the probable effect level, PEL, and the effects range medium, ERM) were employed. In total, 147 sediment samples were tested to determine the content of organic matter and sulfur, as well as the concentrations of terrestrial and rare earth elements (REEs) and toxic metals, namely As, Cd, Cr, Cu, Ni and Hg, using inductively coupled plasma optical emission spectroscopy (ICP-OES). Gulf War oil spills in addition to oil and gas industries of the Pars South Especial Economic Zone (PSEEZ) were identified as the primary source of pollution in the study area. Gulf War contamination in the study area is highlighted by increased levels of Cd and RI at key horizons at 29 cm, 35 cm and 49 cm depth in the sedimentary columns of the Assaluyeh and Bassatin estuaries and Gavbandi River, respectively. Adverse effects of PSEEZ were revealed by increasing concentrations of toxic metals, P and S in the top 25-30 cm of the sedimentary columns. As a result, superficial sediments have been severely polluted by As, Ni, Cd, Cu and Cr, while the entire sedimentary column of the Assaluyeh estuary has been polluted by Hg. Based on the locations of the key horizons, the sedimentation rates of the previous decade at the Assaluyeh and Bassatin estuaries and the Gavbandi River were calculated to be 1.26 cm, 1.52 cm, and 2.13 cm, respectively. The capability of the index analysis approach, as well as of certain lanthanides, for highlighting environmental evolutionary trends in catchments in which extensive land use changes have occurred was demonstrated by the present investigation. The present research concluded that aquatic life and human health in the study area have been subjected to different ranges of hazards by toxic metals due to regional and local anthropogenic activities.

  8. In situ growth of NiCo2S4 nanotube arrays on Ni foam for supercapacitors: Maximizing utilization efficiency at high mass loading to achieve ultrahigh areal pseudocapacitance

    NASA Astrophysics Data System (ADS)

    Chen, Haichao; Jiang, Jianjun; Zhang, Li; Xia, Dandan; Zhao, Yuandong; Guo, Danqing; Qi, Tong; Wan, Houzhao

    2014-05-01

    Self-standing NiCo2S4 nanotube arrays have been in situ grown on Ni foam by the anion-exchange reaction and directly used as the electrode for supercapacitors. The NiCo2S4 nanotube in the arrays effectively reduces the inactive material and increases the electroactive surface area because of the ultrathin wall, which is quite competent to achieve high utilization efficiency at high electroactive materials mass loading. The NiCo2S4 nanotube arrays hybrid electrode exhibits an ultrahigh specific capacitance of 14.39 F cm-2 at 5 mA cm-2 with excellent rate performance (67.7% retention for current increases 30 times) and cycling stability (92% retention after 5000 cycles) at a high mass loading of 6 mg cm-2. High areal capacitance (4.68 F cm-2 at 10 mA cm-2), high energy density (31.5 Wh kg-1 at 156.6 W kg-1) and high power density (2348.5 W kg-1 at 16.6 Wh kg-1) can be achieved by assembling asymmetric supercapacitor with reduced graphene oxide at a total active material mass loading as high as 49.5 mg. This work demonstrates that NiCo2S4 nanotube arrays structure is a superior electroactive material for high-performance supercapacitors even at a mass loading of potential application-specific scale.

  9. Comparison of Marine Boundary Layer Cloud Properties From CERES-MODIS Edition 4 and DOE ARM AMF Measurements at the Azores

    NASA Astrophysics Data System (ADS)

    Dong, X.; Xi, B.; Minnis, P.; Sun-Mack, S.

    2014-12-01

    Marine Boundary Layer (MBL) cloud properties derived for the NASA CERES Project using Terra and Aqua MODIS data are compared with observations taken at DOE ARM Mobile Facility at the Azores site from Jun. 2009 to Dec. 2010. Cloud properties derived from ARM ground-based observations were averaged over a 1-hour interval centered at the satellite overpass time, while the CERES-MODIS (CM) results were averaged within a 30×30 km2 grid box centered over the Azores site. A total of 63 daytime and 92 nighttime single-layered overcast MBL cloud cases were selected from 19 months of ARM radar-lidar and satellite observations. The CM cloud-top/base heights (Htop/Hbase) were determined from cloud-top/base temperatures (Ttop/Tbase) using a regional boundary-layer lapse rate method. For daytime comparisons, the CM-derived Htop (Hbase), on average, is 0.063 km (0.068 km) higher (lower) than its ARM radar-lidar observed counterpart, and the CM-derived Ttop and Tbase are 0.9 K less and 2.5 K greater than the surface values with high correlations (R2=0.82 and 0.84, respectively). In general, the cloud-top comparisons agree better than cloud-base comparisons because the CM Tbase and Hbase are secondary product determined from Ttop and Htop. No significant day-night difference was found in the analyses. The comparisons of microphysical properties reveal that, when averaged over a 30x30 km2 area, the CM-retrieved cloud-droplet effective radius (re) is 1.3 µm larger than that from the ARM retrievals (12.8 µm). While the CM-retrieved cloud liquid water path (LWP) is 13.5 gm-2 less than its ARM counterpart (114.2 gm-2) due to its small optical depth (τ, 9.6 vs. 13.7). The differences are reduced by 50% when the CM averages are computed only using the MODIS pixel nearest the AMF site. Using effective radius retrieved at 2.1-µm channel to calculate LWP can reduce the difference between the CM and ARM from -13.7 to 2.1 gm-2. The 10% differences between the ARM and CM LWP and re retrievals are within the uncertainties of the ARM LWP (~ 20 gm-2) and re (~ 10%) retrievals, however, the 30% difference in τ is significant. Possible reasons contributed to this discrepancy increased sensitivities in τ from both surface retrievals when τ ~ 10 and topography. The τ differences vary with wind direction and are consistent with the island orography.

  10. Decreased Anticipatory Postural Adjustments During Gait Initiation Acutely Postconcussion.

    PubMed

    Buckley, Thomas A; Oldham, Jessie R; Munkasy, Barry A; Evans, Kelsey M

    2017-10-01

    To investigate anticipatory postural adjustments (APAs) during the transitional movement task of gait initiation (GI) in individuals acutely after a concussion. Cohort study. University research center. A population-based sample of participants (N=84) divided into 2 equal groups of acutely postconcussion and healthy student athletes. Participants were tested on 2 occasions: a preinjury baseline test and then the concussion group was retested acutely postconcussion and the healthy student athlete group again at a similar time. All participants completed 5 trials of GI on 4 forceplates. The dependent variables were the displacement and velocity of the center of pressure (COP) during the APA phase and initial step kinematics. Comparisons were made with a 2 (group) × 2 (time) repeated-measures analysis of variance. There was a significant interaction for COP posterior displacement (P<.001) and lateral displacement (P<.001). Posteriorly, post hoc testing identified a significant reduction in the concussion group (pretest: 5.7±1.6cm; posttest: 2.6±2.1cm; P<.001), but no difference in the healthy student athlete group (pretest: 4.0±1.6cm; posttest: 4.0±2.5cm; P=.921). Laterally, post hoc testing identified a significant reduction in the concussion group (pretest: 5.8±2.1cm; posttest: 3.8±1.8cm; P<.001), but no difference in the healthy student athlete group (pretest: 5.0±2.5cm; posttest: 5.2±2.4cm; P=.485). The results of this study suggest difficulty in the planning and execution of GI acutely postconcussion, and posterior APA displacement and velocity are highly effective measures of impaired postural control. Finally, the APA phase is linked to the supplementary motor area, which suggests a supraspinal contribution to postconcussion impaired postural control. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. Differences of skin morphology in Bos indicus, Bos taurus, and their crossbreds

    NASA Astrophysics Data System (ADS)

    Jian, Wang; Duangjinda, M.; Vajrabukka, C.; Katawatin, Suporn

    2014-08-01

    Cutaneous evaporation is the main avenue by which cattle dissipate heat via the involvement of sweat glands and other skin components. The difference in skin morphology between B. indicus and B. taurus has been recognized, as well as differences in their ability to tolerate heat. The objective of this study was to compare skin morphology between B. indicus, B. taurus, and their crossbreds. Skin samples of Sahiwal ( B. indicus) ( n = 10, reddish brown skin) and Holstein Friesian (HF) ( B. taurus) ( n = 10, black and white skin) and crossbred of HF75% ( n = 10, black and white skin) and HF87.5 % ( n = 10, black and white skin) were biopsied for histological study, followed by measurement of skin components. The results indicated that breed significantly affected sweat gland morphology. The shape of the sweat gland, as indicated by the ratio of length/diameter, in Sahiwal was baggier in shape compared to HF (5.99 and 9.52) while values for crossbreds were intermediate (7.82, 8.45). The density and volume of sweat glands in Sahiwal (1,058 glands/cm2; 1.60 μ3 × 10-6) were higher than in HF (920 glands/cm2; 0.51 μ3x10-6) and crossbreds, both HF 75 % (709 glands/cm2; 0.68 μ3 × 10-6) and HF 87.5 % (691 glands/cm2; 0.61 μ3 × 10-6) respectively. However, capillary surface area was greater for HF (2.07 cm2) compared to Sahiwal (1.79 cm2); accordingly, the lower genetic fraction of HF in crossbred cattle showed less capillary surface area (1.83 and 1.9 cm2 for HF75% and HF87.5 %) ( P < 0.01). Nerve density was not significantly different between Sahiwal and HF but was higher in the crossbred ( P < 0.01) cattle. Moreover, the effect of skin color (black and white) was evaluated and it was found that there was an interaction ( P < 0.01) between breed and skin color on the skin components. This study reveals that there are differences in skin morphology among B. indicus, B. taurus and their crossbreds, with these differences being more or less related to the genetic fraction of HF. This may imply that capability for cutaneous evaporative heat loss and tolerance to heat in crossbred cattle could be related to skin morphology.

  12. On the Spectral Variance of MGS TES Spectra in the 300-500 cm-1 Range

    NASA Astrophysics Data System (ADS)

    Altieri, F.; Bellucci, G.

    2001-11-01

    The Thermal Emission Spectrometer (TES) aboard NASA mission Mars Global Surveyor (MGS) is collecting 200 - 1600 cm-1 thermal emission spectra since September 1997. The principal purpose of TES is to determine and map the Mars surface composition. Spectral features directly ascribable to surface minerals have been identified in the 300 - 500 cm-1 spectral range. Outcrops of hematite have been localized in Sinus Meridiani, Aram Chaos and Valles Marineris [1, 2] and areas with olivine have been individuated in Nili Fossae and in other limited regions [3]. On the other hand, TES spectra show, in general, significant variance between 300 and 500 cm-1; this variance is not directly attributable to surface mineralogical components. In this study we report some examples of spectra with typical hematite and olivine bands and spectra with a different spectral contrast. The spectral masking effect of a dust layer is suggested to explain this behaviour. Spectra characterized by hematite features have been localized also inside a crater near Baldet Crater. The MOC narrow-angle image M02-0039 acquired on the same area shows dark layers at the crater bottom. References: [1] Christensen P. R., et al., JGR, 105, 9623-9642, 2000. [2] Christensen P. R., et al., JGR, in press., 2001. [3] Hoefen T. M. and Clark R. N., LPS XXXII, 2049, 2001.

  13. Measurement area and repeatability of semiautomated assessment of corneal endothelium in the Topcon specular microscope SP-2000P and IMAGEnet system.

    PubMed

    Ding, Xiaohu; Huang, Qunxiao; Zheng, Yingfeng; Jiang, Yuzhen; Huang, Shengsong; He, Mingguang

    2012-10-01

    To investigate the repeatability of the semiautomatic assessment of corneal endothelial cells and its association with the measurement area in the Topcon SP-2000P microscope and IMAGEnet system. Specular microscopic images of 86 healthy subjects were captured and analyzed using the Topcon SP-2000P microscope and IMAGEnet system. The same images were analyzed twice, on separate days, by the same examiner using the built-in measurement tool of the IMAGEnet system. The measurement areas were defined with a frame mounted on a computer screen. Four different-sized measurement areas were chosen for the semiautomatic measurements: box A (5.4 × 13.9 cm(2)), box B (4 × 10 cm(2)), box C (4 × 7 cm(2)), and box D (2 × 5 cm(2)). Average cell size (ACS), endothelial cell density (ECD), coefficient of variance, and hexagonality were measured. Repeatability was assessed based on the limit of agreement (LOA). The means of ACS, ECD, and hexagonality were not statistically different across 4 measurement areas (analysis of variance, P > 0.05). The mean differences (bias) were modest for ACS (range, -1.9∼3.9 μm(2)), ECD (range, -27.2∼14.6 cells per square millimeter), coefficient of variance (range, -0.14∼1.00), and hexagonality (range, -1.3%∼6.8%). Limits of agreement (mean difference ± 1.96× SD) were greater in the measurements with smaller areas: limit of agreement values for ECD were 14.6 ± 99.6, -3.8 ± 101.1, -27.2 ± 179, and -15.8 ± 488 cells per square millimeter for boxes A, B, C, and D, respectively. Similar trends were found in the repeatability of ACS and hexagonality. Repeatability is improved when larger measurement areas are chosen.

  14. Role of Firing Temperature, Sheet Resistance, and Contact Area in Contact Formation on Screen-Printed Metal Contact of Silicon Solar Cell

    NASA Astrophysics Data System (ADS)

    Ahmad, Samir Mahmmod; Leong, Cheow Siu; Sopian, K.; Zaidi, Saleem H.

    2018-03-01

    Formation of an Ohmic contact requires a suitable firing temperature, appropriate doping profile, and contact dimensions within resolution limits of the screen-printing process. In this study, the role of the peak firing temperature in standard rapid thermal annealing (RTA) six-zone conveyor belt furnace (CBF) and two inexpensive alternate RTA systems [a custom-designed, three-zone, 5″-diameter quartz tube furnace (QTF) and a tabletop, 3″-diameter rapid thermal processing (RTP)] has been investigated. In addition, the role of sheet resistance and contact area in achieving low-resistance ohmic contacts has been examined. Electrical measurements of ohmic contacts between silver paste/ n +-emitter layer with varying sheet resistances and aluminum paste/ p-doped wafer were carried out in transmission line method configuration. Experimental measurements of the contact resistivity ( ρ c) exhibited the lowest values for CBF at 0.14 mΩ cm2 for Ag and 100 mΩ cm2 for Al at a peak firing temperature of 870°C. For the QTF configuration, lowest measured contact resistivities were 3.1 mΩ cm2 for Ag and 74.1 mΩ cm2 for Al at a peak firing temperature of 925°C. Finally, for the RTP configuration, lowest measured contact resistivities were 1.2 mΩ cm2 for Ag and 68.5 mΩ cm2 for Al at a peak firing temperature of 780°C. The measured contact resistivity exhibits strong linear dependence on sheet resistance. The contact resistivity for Ag decreases with contact area, while for Al the opposite behavior is observed.

  15. Large-area flexible monolithic ITO/WO3/Nb2O5/NiVOχ/ITO electrochromic devices prepared by using magnetron sputter deposition

    NASA Astrophysics Data System (ADS)

    Tang, Chien-Jen; Ye, Jia-Ming; Yang, Yueh-Ting; He, Ju-Liang

    2016-05-01

    Electrochromic devices (ECDs) have been applied in smart windows to control the transmission of sunlight in green buildings, saving up to 40-50% electricity consumption and ultimately reducing carbon dioxide emissions. However, the high manufacturing costs and difficulty of transportation of conventional massive large area ECDs has limited widespread applications. A unique design replacing the glass substrate commonly used in the ECD windows with inexpensive, light-weight and flexible polymeric substrate materials would accelerate EC adoption allowing them to be supplemented for regular windows without altering window construction. In this study, an ITO/WO3/Nb2O5/NiVOχ/ITO all-solid-state monolithic ECD with an effective area of 24 cm × 18 cm is successfully integrated on a PET substrate by using magnetron sputter deposition. The electrochromic performance and bending durability of the resultant material are also investigated. The experimental results indicate that the ultimate response times for the prepared ECD is 6 s for coloring at an applied voltage of -3 V and 5 s for bleaching at an applied voltage of +3 V, respectively. The optical transmittances for the bleached and colored state at a wavelength of 633 nm are 53% and 11%, respectively. The prepared ECD can sustain over 8000 repeated coloring and bleaching cycles, as well as tolerate a bending radius of curvature of 7.5 cm.

  16. Transport of atrazine, 2,4-D, and dicamba through preferential flowpaths in an unsaturated claypan soil near Centralia, Missouri

    NASA Astrophysics Data System (ADS)

    Tindall, James A.; Vencill, William K.

    1995-03-01

    The objectives were to determine how atrazine (2-chloro-4-(ethylamino)-6-(isopropylamino)- s-triazine), dicamba (3-6-dichloro-2-methoxybenzoic acid), and 2,4-D (2,4-dichlorophenoxy-acetic acid) move through claypan soils (fine montmorillonitic, mesic Udollic Ochraqualf Mollic albaqualf, Mexico silty loam) at the Missouri Management System Evaluation Area (MSEA) near Centralia in Boone County, Missouri, and the role of preferential flowpaths in that movement. Twelve intact soil cores (30 cm diameter by 40 cm height), were excavated sequentially, four from each of the following depths: 0-40 cm, 40-80 cm, and 80-120 cm. These cores were used to study preferential flow characteristics using dye staining experiments and to determine hydraulic properties. Six undisturbed experimental field plots, with a 1 m 2 surface area (two sets of three each), were instrumented at the Missouri MSEA on 11 May 1991: 1 m 2 zero-tension pan lysimeters were installed at 1.35 m depths in Plots 1-3 and at 1.05 m depths in Plots 4-6. Additionally, each plot was planted with soybeans ( Glycine max L.) and instrumented with suction lysimeters and tensiometers at 15 cm depth increments. A neutron probe access tube was installed in each plot to determine soil water content at 15 cm intervals. All plots were enclosed with a raised frame (of 8 cm height) to prevent surface runoff, and were allowed to equilibrate for a year before data collection. During this waiting period, all suction and pan lysimeters were purged monthly and were sampled immediately prior to herbicide application in May 1992 to obtain background concentrations. Atrazine, 2,4-D, and dicamba moved rapidly through the soil, probably owing to the presence of preferential flowpaths. Staining of laboratory cores showed a positive correlation between the per cent area stained by depth and the subsequent breakthrough of Br - in the laboratory and leaching of field-applied herbicides owing to large rainfall events. Suction lysimeter samples in the field showed increases in concentrations of herbicides at depths where laboratory data indicated greater percentages of what appeared to be preferential flowpaths. Concentrations of atrazine, 2,4-D, and dicamba exceeding 0.50, 0.1, and 0.15 μg ml -1 were observed with depth (45-135 cm, 60-125 cm and 60-135 cm) after several months following rainfall events. Preferential flowpaths were a major factor in transport of atrazine, 2,4-D, and dicamba at the site.

  17. Floor space covered by broiler chickens kept at stocking densities according to Council Directive 2007/43/EC.

    PubMed

    Giersberg, M F; Hartung, J; Kemper, N; Spindler, B

    2016-07-30

    It is controversially discussed whether the stocking densities set by the EU Directive 2007/43/EC allow a species-appropriate housing of broiler chickens. To calculate the exact area broilers occupy due to their physical size and shape, planimetric measurements using a colour-contrast method were carried out. In total, 1949 photographs of standing and 1482 of squatting chickens, taken from a top view, were analysed. A computer program counted the pixels representing the previously weighed animal in the photograph and calculated the animal area. The average area covered by chickens with 400 g live weight was 116.64±13.12 cm(2) in a standing and 138.61±12.92 cm(2) in a squatting position. These areas increased linearly as a function of live weight to 452.57±58.89 cm(2) (R(2)=0.90 standing) and 513.54±42.70 cm(2) (R(2)=0.82 squatting) at the end of the study (3200 g live weight). Squatting chickens occupied more space compared with a standing position in most of the tested weight classes (P<0.05). Depending on target weights, stocking densities and body positions, broilers occupied 48.5-77.7 per cent of 1 m(2) Thus, from a physical point of view, simultaneous resting is possible at any stocking density provided by the EU Directive and at common target weights. British Veterinary Association.

  18. SU-F-T-75: Dosimetry Considerations in the Use of Hanging-Eye Block for Lesions of the Conjunctiva

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grelewicz, Z; Lee, B; Cutright, D

    Purpose: Superficial lesions in the conjunctiva are frequently treated with en face electrons, using a hanging block to spare dose to the lens of the eye. Dose to the tumor and lens depend on the design and setup of the block and supporting apparatus. We performed in phantom measurements in order to characterize the dose sparing effects of the block as well as the under-dosing effect under the supporting apparatus for 6 MeV treatment. Methods: The commercial hanging block studied uses a 1.2 cm diameter tungsten cylinder supported by a 3 mm diameter acrylic rod. Point dose measurements under themore » hanging block, under an unblocked part of the field, and under the acrylic rod were performed using MOSFET detectors. In addition, EBT3 film was used for both PDD and profile measurements at a depth in phantom of 3 mm for both 105 and 103 cm SSD. Results: MOSFET measurements reported a dose reduction of 95% under the tungsten block when using an SSD of 103 cm, and 86% when using an SSD of 105 cm at a depth in phantom of 3 mm. Film measurements showed that the area under the acrylic rod may be under-dosed by as much as 30% when using 103 SSD. MOSFET measurements confirmed that when using an SSD of 103 cm, the area under the acrylic rod is under-dosed by up to 30% at 3mm depth, compared to the unblocked part of the field. Conclusion: The effectiveness of the commercial hanging block apparatus depends on setup, with 95% lens sparing possible with an SSD of 103 cm. This short SSD is necessary for sharp penumbra. At this SSD, substantial under-dosing under the acrylic support rod is possible. This must be mitigated with either feathering, or using an alternative method of support for the tungsten block.« less

  19. 4H-SiC UV Photo Detector with Large Area and Very High Specific Detectivity

    NASA Technical Reports Server (NTRS)

    Yan, Feng; Shahid, Aslam; Franz, David; Xin, Xiaobin; Zhao, Jian H.; Zhao, Yuegang; Winer, Maurice

    2004-01-01

    Pt/4H-SiC Schottky photodiodes have been fabricated with the device areas up to 1 sq cm. The I-V characteristics and photo-response spectra have been measured and analyzed. For a 5 mm x 5 mm area device leakage current of 1 x 10(exp 15)A at zero bias and 1.2 x 10(exp 14)A at -IV have been established. The quantum efficiency is over 30% from 240nm to 320nm. The specific detectivity, D(sup *), has been calculated from the directly measured leakage current and quantum efficiency data and are shown to be higher than 10(exp 15) cmHz(sup 1/2)/W from 210nm to 350nm with a peak D(sup *) of 3.6 x 10(exp 15)cmH(sup 1/2)/W at 300nm.

  20. The effect of voxel size on dose distribution in Varian Clinac iX 6 MV photon beam using Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Yani, Sitti; Dirgayussa, I. Gde E.; Rhani, Moh. Fadhillah; Haryanto, Freddy; Arif, Idam

    2015-09-01

    Recently, Monte Carlo (MC) calculation method has reported as the most accurate method of predicting dose distributions in radiotherapy. The MC code system (especially DOSXYZnrc) has been used to investigate the different voxel (volume elements) sizes effect on the accuracy of dose distributions. To investigate this effect on dosimetry parameters, calculations were made with three different voxel sizes. The effects were investigated with dose distribution calculations for seven voxel sizes: 1 × 1 × 0.1 cm3, 1 × 1 × 0.5 cm3, and 1 × 1 × 0.8 cm3. The 1 × 109 histories were simulated in order to get statistical uncertainties of 2%. This simulation takes about 9-10 hours to complete. Measurements are made with field sizes 10 × 10 cm2 for the 6 MV photon beams with Gaussian intensity distribution FWHM 0.1 cm and SSD 100.1 cm. MC simulated and measured dose distributions in a water phantom. The output of this simulation i.e. the percent depth dose and dose profile in dmax from the three sets of calculations are presented and comparisons are made with the experiment data from TTSH (Tan Tock Seng Hospital, Singapore) in 0-5 cm depth. Dose that scored in voxels is a volume averaged estimate of the dose at the center of a voxel. The results in this study show that the difference between Monte Carlo simulation and experiment data depend on the voxel size both for percent depth dose (PDD) and profile dose. PDD scan on Z axis (depth) of water phantom, the big difference obtain in the voxel size 1 × 1 × 0.8 cm3 about 17%. In this study, the profile dose focused on high gradient dose area. Profile dose scan on Y axis and the big difference get in the voxel size 1 × 1 × 0.1 cm3 about 12%. This study demonstrated that the arrange voxel in Monte Carlo simulation becomes important.

  1. Self-expanding Portico Valve Versus Balloon-expandable SAPIEN XT Valve in Patients With Small Aortic Annuli: Comparison of Hemodynamic Performance.

    PubMed

    Del Trigo, María; Dahou, Abdellaziz; Webb, John G; Dvir, Danny; Puri, Rishi; Abdul-Jawad Altisent, Omar; Campelo-Parada, Francisco; Thompson, Chris; Leipsic, Jonathon; Stub, Dion; DeLarochellière, Robert; Paradis, Jean-Michel; Dumont, Eric; Doyle, Daniel; Mohammadi, Siamak; Pasian, Sergio; Côté, Melanie; Pibarot, Philippe; Rodés-Cabau, Josep

    2016-05-01

    The self-expanding Portico valve is a new transcatheter aortic valve system yielding promising preliminary results, yet there are no comparative data against earlier generation transcatheter aortic valve systems. The aim of this study was to compare the hemodynamic performance of the Portico and balloon-expandable SAPIEN XT valves in a case-matched study with echocardiographic core laboratory analysis. Twenty-two patients underwent transcatheter aortic valve implantation with the Portico 23-mm valve and were matched for aortic annulus area and mean diameter measured by multidetector computed tomography, left ventricular ejection fraction, body surface area, and body mass index with 40 patients treated with the 23-mm SAPIEN XT. Mean aortic annulus diameters were 19.6±1.3mm by transthoracic echocardiography and 21.4±1.2mm by computed tomography, with no significant between-group differences. Doppler echocardiographic images were collected at baseline and at 1-month of follow-up and were analyzed in a central echocardiography core laboratory. There were no significant between-group differences in residual mean transaortic gradients (SAPIEN XT: 10.4±3.7mmHg; Portico: 9.8±1.1mmHg; P=.49) and effective orifice areas (SAPIEN XT: 1.36±0.27cm(2); Portico, 1.37±.29cm(2); P=.54). Rates of severe prosthesis-patient mismatch (effective orifice area<0.65cm(2)/m(2)) were similar (SAPIEN XT: 13.5%; Portico: 10.0%; P=.56). No between-group differences were found in the occurrence of moderate-severe paravalvular leaks (5.0% vs 4.8% of SAPIEN XT and Portico respectively; P=.90). Transcatheter aortic valve implantation with the self-expanding Portico system yielded similar short-term hemodynamic performance compared with the balloon-expandable SAPIEN XT system for treating patients with severe aortic stenosis and small annuli. Further prospective studies with longer-term follow-up and in patients with larger aortic annuli are required. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  2. Treatment of Carpal Tunnel Syndrome in pregnancy with Polarized Polychromatic Non-coherent Light (Bioptron Light): A Preliminary, Prospective, Open Clinical Trial.

    PubMed

    Dimitrios, Stasinopoulos; Stasinopoulos, Loannis

    2017-12-31

    The aim of this trial was to assess the efficacy of polarized polychromatic noncoherent light (Bioptron light) in the treatment of Carpal Tunnel Syndrome (CTS) in pregnancy. An uncontrolled experimental study was conducted in pregnant patients with CTS who visited our clinic from January 2006 to January 2010. Bioptron light (480-3400 nm; 95% polarization; 40 mW/cm 2 ; and 2.4 J/cm 2 ) was administered perpendicular to the carpal tunnel area. The irradiation time for each session was 6 min at an operating distance of 5-10 cm from the carpal tunnel area, twice each day, five days per week for 2 weeks. Pain and paraesthesia using a visual analogue scale (VAS) and finger pinch strength were evaluated at the end of treatment (week 2) and 1-month (week 6) after the end of treatment. The Student'sttest was used and p values < 0.05 were accepted as statistically significant. 46 patients participated in the study. The mean age of subjects was 27.6 years (range 22-37). The patient population had a mean duration of CTS of 2.3 months (range 1-4). All patients were in the third trimester. Pain and paraesthesia decreased at the end of treatment and at the 1-month follow-up, whereas the finger pinch strength increased at the end of treatment and at the 1-month follow-up. In conclusion, the results of the present study suggest that Bioptron light is a reliable, safe, and effective treatment option in pregnant patients with CTS. Controlled clinical trials are needed to establish the absolute and relative effectiveness of this intervention.

  3. Radiometric and geometric characteristics of Pleiades images

    NASA Astrophysics Data System (ADS)

    Jacobsen, K.; Topan, H.; Cam, A.; Özendi, M.; Oruc, M.

    2014-11-01

    Pleiades images are distributed with 50 cm ground sampling distance (GSD) even if the physical resolution for nadir images is just 70 cm. By theory this should influence the effective GSD determined by means of point spread function at image edges. Nevertheless by edge enhancement the effective GSD can be improved, but this should cause enlarged image noise. Again image noise can be reduced by image restoration. Finally even optimized image restoration cannot improve the image information from 70 cm to 50 cm without loss of details, requiring a comparison of Pleiades image details with other very high resolution space images. The image noise has been determined by analysis of the whole images for any sub-area with 5 pixels times 5 pixels. Based on the standard deviation of grey values in the small sub-areas the image noise has been determined by frequency analysis. This leads to realistic results, checked by test targets. On the other hand the visual determination of image noise based on apparently homogenous sub-areas results in too high values because the human eye is not able to identify small grey value differences - it is limited to just approximately 40 grey value steps over the available gray value range, so small difference in grey values cannot be seen, enlarging results of a manual noise determination. A tri-stereo combination of Pleiades 1A in a mountainous, but partially urban, area has been analyzed and compared with images of the same area from WorldView-1, QuickBird and IKONOS. The image restoration of the Pleiades images is very good, so the effective image resolution resulted in a factor 1.0, meaning that the effective resolution corresponds to the nominal resolution of 50 cm. This does not correspond to the physical resolution of 70 cm, but by edge enhancement the steepness of the grey value profile across the edge can be enlarged, reducing the width of the point spread function. Without additional filtering edge enhancement enlarges the image noise, but the average image noise of approximately 1.0 grey values related to 8 bit images is very small, not indicating the edge enhancement and the down sampling of the GSD from 70 cm to 50 cm. So the direct comparison with the other images has to give the answer if the image quality of Pleiades images is on similar level as corresponding to the nominal resolution. As expected with the image geometry there is no problem. This is the case for all used space images in the test area, where the point identification limits the accuracy of the scene orientation.

  4. Chemical Vapor-Deposited Hexagonal Boron Nitride as a Scalable Template for High-Performance Organic Field-Effect Transistors

    DOE PAGES

    Lee, Tae Hoon; Kim, Kwanpyo; Kim, Gwangwoo; ...

    2017-02-27

    Organic field-effect transistors have attracted much attention because of their potential use in low-cost, large-area, flexible electronics. High-performance organic transistors require a low density of grain boundaries in their organic films and a decrease in the charge trap density at the semiconductor–dielectric interface for efficient charge transport. In this respect, the role of the dielectric material is crucial because it primarily determines the growth of the film and the interfacial trap density. Here, we demonstrate the use of chemical vapor-deposited hexagonal boron nitride (CVD h-BN) as a scalable growth template/dielectric for high-performance organic field-effect transistors. The field-effect transistors based onmore » C60 films grown on single-layer CVD h-BN exhibit an average mobility of 1.7 cm 2 V –1 s –1 and a maximal mobility of 2.9 cm 2 V –1 s –1 with on/off ratios of 10 7. The structural and morphology analysis shows that the epitaxial, two-dimensional growth of C 60 on CVD h-BN is mainly responsible for the superior charge transport behavior. In conclusion, we believe that CVD h-BN can serve as a growth template for various organic semiconductors, allowing the development of large-area, high-performance flexible electronics.« less

  5. Chemical Vapor-Deposited Hexagonal Boron Nitride as a Scalable Template for High-Performance Organic Field-Effect Transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Tae Hoon; Kim, Kwanpyo; Kim, Gwangwoo

    Organic field-effect transistors have attracted much attention because of their potential use in low-cost, large-area, flexible electronics. High-performance organic transistors require a low density of grain boundaries in their organic films and a decrease in the charge trap density at the semiconductor–dielectric interface for efficient charge transport. In this respect, the role of the dielectric material is crucial because it primarily determines the growth of the film and the interfacial trap density. Here, we demonstrate the use of chemical vapor-deposited hexagonal boron nitride (CVD h-BN) as a scalable growth template/dielectric for high-performance organic field-effect transistors. The field-effect transistors based onmore » C60 films grown on single-layer CVD h-BN exhibit an average mobility of 1.7 cm 2 V –1 s –1 and a maximal mobility of 2.9 cm 2 V –1 s –1 with on/off ratios of 10 7. The structural and morphology analysis shows that the epitaxial, two-dimensional growth of C 60 on CVD h-BN is mainly responsible for the superior charge transport behavior. In conclusion, we believe that CVD h-BN can serve as a growth template for various organic semiconductors, allowing the development of large-area, high-performance flexible electronics.« less

  6. Electrical, spectral and optical performance of yellow-green and amber micro-pixelated InGaN light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Gong, Z.; Liu, N. Y.; Tao, Y. B.; Massoubre, D.; Xie, E. Y.; Hu, X. D.; Chen, Z. Z.; Zhang, G. Y.; Pan, Y. B.; Hao, M. S.; Watson, I. M.; Gu, E.; Dawson, M. D.

    2012-01-01

    Micro-pixelated InGaN LED arrays operating at 560 and 600 nm, respectively, are demonstrated for what the authors believe to be the first time. Such devices offer applications in areas including bioinstrumentation, visible light communications and optoelectronic tweezers. The devices reported are based on new epitaxial structures, retaining conventional (0 0 0 1) orientation, but incorporating electron reservoir layers which enhance the efficiency of radiative combination in the active regions. A measured output optical power density up to 8 W cm-2 (4.4 W cm-2) has been achieved from a representative pixel of the yellow-green (amber) LED array, substantially higher than that from conventional broad-area reference LEDs fabricated from the same wafer material. Furthermore, these micro-LEDs can sustain a high current density, up to 4.5 kA cm-2, before thermal rollover. A significant blueshift of the emission wavelength with increasing injection current is observed, however. This blueshift saturates at 45 nm (50 nm) for the yellow-green (amber) LED array, and numerical simulations have been used to gain insight into the responsible mechanisms in this microstructured format of device. In the relatively low-current-density regime (<3.5 kA cm-2) the blueshift is attributable to both the screening of the piezoelectric field by the injected carriers and the band-filling effect, whereas in the high-current regime, it is mainly due to band-filling. Further development of the epitaxial wafer material is expected to improve the current-dependent spectral stability.

  7. AuCl3 doping-induced conductive unstability for CVD-grown graphene on glass substrate

    NASA Astrophysics Data System (ADS)

    Wang, Jiaqing; Liu, Xianming; Cao, Xueying; Zhang, Peng; Lei, Xiaohua; Chen, Weimin

    2017-09-01

    Graphene is a candidate material for next-generation high performance transparent conducting film (TCF) to replace indium tin oxide (ITO) materials. However, the sheet resistance of large area graphene obtained by the chemical vapor deposition (CVD) method is higher than other kinds of TCFs. The main strategies for improving the electrical conductivity of graphene films have been based on various doping treatments. AuCl3 is one of the most effective dopants. In this paper, we investigate the influence of AuCl3 doping on the conductive stability of CVD-grown graphene. Large area graphene film synthesized by CVD and transferred to glass substrates is taken as experimental sample. AuCl3 in nitromethane is used to dope the graphene films to improve the electrical conductivity. Another sample without doping is prepared for comparison. The resistances of graphene under periodic visible light irradiation with and without AuCl3 doping are measured. Results show that the resistances for all samples increase exponentially under lighting, while decrease slowly in an exponential form as well after the light is switched off. The relative resistance changes for undoped and doped samples are compared under 445nm light irradiation with 40mW/cm2, 60mW/cm2, 80mW/cm2, 100mW/cm2 in atmosphere and vacuum. The change rate and degree for doped graphene are greater than that of undoped graphene. It is evident from the experimental data that AuCl3 doping may induce conductive unstability for CVD-grown graphene on glass substrate.

  8. Snow depth on Arctic sea ice from historical in situ data

    NASA Astrophysics Data System (ADS)

    Shalina, Elena V.; Sandven, Stein

    2018-06-01

    The snow data from the Soviet airborne expeditions Sever in the Arctic collected over several decades in March, April and May have been analyzed in this study. The Sever data included more measurements and covered a much wider area, particularly in the Eurasian marginal seas (Kara Sea, Laptev Sea, East Siberian Sea and Chukchi Sea), compared to the Soviet North Pole drifting stations. The latter collected data mainly in the central part of the Arctic Basin. The following snow parameters have been analyzed: average snow depth on the level ice (undisturbed snow) height and area of sastrugi, depth of snow dunes attached to ice ridges and depth of snow on hummocks. In the 1970s-1980s, in the central Arctic, the average depth of undisturbed snow was 21.2 cm, the depth of sastrugi (that occupied about 30 % of the ice surface) was 36.2 cm and the average depth of snow near hummocks and ridges was about 65 cm. For the marginal seas, the average depth of undisturbed snow on the level ice varied from 9.8 cm in the Laptev Sea to 15.3 cm in the East Siberian Sea, which had a larger fraction of multiyear ice. In the marginal seas the spatial variability of snow depth was characterized by standard deviation varying between 66 and 100 %. The average height of sastrugi varied from 23 cm to about 32 cm with standard deviation between 50 and 56 %. The average area covered by sastrugi in the marginal seas was estimated to be 36.5 % of the total ice area where sastrugi were observed. The main result of the study is a new snow depth climatology for the late winter using data from both the Sever expeditions and the North Pole drifting stations. The snow load on the ice observed by Sever expeditions has been described as a combination of the depth of undisturbed snow on the level ice and snow depth of sastrugi weighted in proportion to the sastrugi area. The height of snow accumulated near the ice ridges was not included in the calculations because there are no estimates of the area covered by those features from the Sever expeditions. The effect of not including that data can lead to some underestimation of the average snow depth. The new climatology refines the description of snow depth in the central Arctic compared to the results by Warren et al. (1999) and provides additional detailed data in the marginal seas. The snow depth climatology is based on 94 % Sever data and 6 % North Pole data. The new climatology shows lower snow depth in the central Arctic comparing to Warren climatology and more detailed data in the Eurasian seas.

  9. Physical Activation of Oil Palm Empty Fruit Bunch via CO2 Activation Gas for CO2 Adsorption

    NASA Astrophysics Data System (ADS)

    Joseph, C. G.; Quek, K. S.; Daud, W. M. A. W.; Moh, P. Y.

    2017-06-01

    In this study, different parameters for the preparation of activated carbon were investigated for their yield and CO2 capture capabilities. The activated carbon was prepared from Oil Palm Empty Fruit Bunch (OPEFB) via a 2-step physical activation process. The OPEFB was pyrolyzed under inert conditions at 500 °C and activated via CO2. A 2-factorial design was employed and the effects of activation temperature, activation dwell time and gas flow rate on yield and CO2 capture capabilities were compared and studied. The yield obtained ranged from between 20 - 26, whereby the temperature was determined to be the most significant factor in influencing CO2 uptake. The CO2 capture capacity was determined using Temperature Programmed Desorption (TPD) technique. The CO2 uptake of EFB activated carbon achieved was between 1.85 - 2.09 mmol/g. TPD analysis has shown that the surface of AC were of basic nature. AC was found to be able to withhold the CO2 up to 663°C before maximum desorption occurs. The surface area and pore size of OPEFB obtained from BET analysis is 2.17 m2 g-1 and 0.01 cm3 g-1. After activation, both surface area and pore size increased with a maximum observed surface area and pore size of 548.07 m2 g-1 and 0.26 cm3 g-1. Surface morphology, functional groups, pore size and surface area were analyzed using SEM, FT-IR, TPD and BET.

  10. Effect of reclamation on soil organic carbon pools in coastal areas of eastern China

    NASA Astrophysics Data System (ADS)

    Li, Jianguo; Yang, Wenhui; Li, Qiang; Pu, Lijie; Xu, Yan; Zhang, Zhongqi; Liu, Lili

    2018-04-01

    The coastal wetlands of eastern China form one of the most important carbon sinks in the world. However, reclamation can significantly alter the soil carbon pool dynamics in these areas. In this study, a chronosequence was constructed for four reclamation zones in Rudong County, Jiangsu Province, eastern China (reclaimed in 1951, 1974, 1982, and 2007) and a reference salt marsh to identify both the process of soil organic carbon (SOC) evolution, as well as the effect of cropping and soil properties on SOC with time after reclamation. The results show that whereas soil nutrient elements and SOC increased after reclamation, the electrical conductivity of the saturated soil extract (ECe), pH, and bulk density decreased within 62 years following reclamation and agricultural amendment. In general, the soil's chemical properties remarkably improved and SOC increased significantly for approximately 30 years after reclamation. Reclamation for agriculture (rice and cotton) significantly increased the soil organic carbon density (SOCD) in the top 60 cm, especially in the top 0-30 cm. However, whereas the highest concentration of SOCD in rice-growing areas was in the top 0-20 cm of the soil profile, it was greater at a 20-60 cm depth in cottongrowing areas. Reclamation also significantly increased heavy fraction organic carbon (HFOC) levels in the 0-30 cm layer, thereby enhancing the stability of the soil carbon pool. SOC can thus increase significantly over a long time period after coastal reclamation, especially in areas of cultivation, where coastal SOC pools in eastern China tend to be more stable.

  11. Effect of reclamation on soil organic carbon pools in coastal areas of eastern China

    NASA Astrophysics Data System (ADS)

    Li, Jianguo; Yang, Wenhui; Li, Qiang; Pu, Lijie; Xu, Yan; Zhang, Zhongqi; Liu, Lili

    2018-06-01

    The coastal wetlands of eastern China form one of the most important carbon sinks in the world. However, reclamation can significantly alter the soil carbon pool dynamics in these areas. In this study, a chronosequence was constructed for four reclamation zones in Rudong County, Jiangsu Province, eastern China (reclaimed in 1951, 1974, 1982, and 2007) and a reference salt marsh to identify both the process of soil organic carbon (SOC) evolution, as well as the effect of cropping and soil properties on SOC with time after reclamation. The results show that whereas soil nutrient elements and SOC increased after reclamation, the electrical conductivity of the saturated soil extract (ECe), pH, and bulk density decreased within 62 years following reclamation and agricultural amendment. In general, the soil's chemical properties remarkably improved and SOC increased significantly for approximately 30 years after reclamation. Reclamation for agriculture (rice and cotton) significantly increased the soil organic carbon density (SOCD) in the top 60 cm, especially in the top 0-30 cm. However, whereas the highest concentration of SOCD in rice-growing areas was in the top 0-20 cm of the soil profile, it was greater at a 20-60 cm depth in cottongrowing areas. Reclamation also significantly increased heavy fraction organic carbon (HFOC) levels in the 0-30 cm layer, thereby enhancing the stability of the soil carbon pool. SOC can thus increase significantly over a long time period after coastal reclamation, especially in areas of cultivation, where coastal SOC pools in eastern China tend to be more stable.

  12. Aortic valve orifice equation independent of valvular flow intervals: application to aortic valve area computation in aortic stenosis and comparison with the Gorlin formula.

    PubMed

    Seitz, W; Oppenheimer, L; McIlroy, M; Nelson, D; Operschall, J

    1986-12-01

    An orifice equation is derived relating the effective aortic valve area, A, the average aortic valve pressure gradient, dP, the stroke volume, SV, and the heart frequency, FH, through considerations of momentum conservation across the aortic valve. This leads to a formula consistent with Newton's second law of motion. The form of the new equation is A = (7.5 X 10(-5)) SV FH2/Pd, where A, VS, FH and Pd are expressed in cm2, ml, s-1 and mmHg, respectively. Aortic valve areas computed with the new orifice equation are found to correlate with those computed by the Gorlin formula in conditions of resting haemodynamic states at a level of r = 0.86, SE = 0.25 cm2, N = 120. The results suggest that the new formula may be considered as an independent orifice equation having a similar domain of validity as the Gorlin formula. The new equation offers the possibility of deriving additional useful haemodynamic relationships through combination with established cardiological formulas and applying it in a noninvasive Doppler ultrasonic or echocardiographic context.

  13. Piezoelectricity in two dimensions: Graphene vs. molybdenum disulfide

    NASA Astrophysics Data System (ADS)

    Song, Xiaoxue; Hui, Fei; Knobloch, Theresia; Wang, Bingru; Fan, Zhongchao; Grasser, Tibor; Jing, Xu; Shi, Yuanyuan; Lanza, Mario

    2017-08-01

    The synthesis of piezoelectric two-dimensional (2D) materials is very attractive for implementing advanced energy harvesters and transducers, as these materials provide enormously large areas for the exploitation of the piezoelectric effect. Among all 2D materials, molybdenum disulfide (MoS2) has shown the largest piezoelectric activity. However, all research papers in this field studied just a single material, and this may raise concerns because different setups could provide different values depending on experimental parameters (e.g., probes used and areas analyzed). By using conductive atomic force microscopy, here we in situ demonstrate that the piezoelectric currents generated in MoS2 are gigantic (65 mA/cm2), while the same experiments in graphene just showed noise currents. These results provide the most reliable comparison yet reported on the piezoelectric effect in graphene and MoS2.

  14. Effect of processing time delay on the dose response of Kodak EDR2 film.

    PubMed

    Childress, Nathan L; Rosen, Isaac I

    2004-08-01

    Kodak EDR2 film is a widely used two-dimensional dosimeter for intensity modulated radiotherapy (IMRT) measurements. Our clinical use of EDR2 film for IMRT verifications revealed variations and uncertainties in dose response that were larger than expected, given that we perform film calibrations for every experimental measurement. We found that the length of time between film exposure and processing can affect the absolute dose response of EDR2 film by as much as 4%-6%. EDR2 films were exposed to 300 cGy using 6 and 18 MV 10 x 10 cm2 fields and then processed after time delays ranging from 2 min to 24 h. An ion chamber measured the relative dose for these film exposures. The ratio of optical density (OD) to dose stabilized after 3 h. Compared to its stable value, the film response was 4%-6% lower at 2 min and 1% lower at 1 h. The results of the 4 min and 1 h processing time delays were verified with a total of four different EDR2 film batches. The OD/dose response for XV2 films was consistent for time periods of 4 min and 1 h between exposure and processing. To investigate possible interactions of the processing time delay effect with dose, single EDR2 films were irradiated to eight different dose levels between 45 and 330 cGy using smaller 3 x 3 cm2 areas. These films were processed after time delays of 1, 3, and 6 h, using 6 and 18 MV photon qualities. The results at all dose levels were consistent, indicating that there is no change in the processing time delay effect for different doses. The difference in the time delay effect between the 6 and 18 MV measurements was negligible for all experiments. To rule out bias in selecting film regions for OD measurement, we compared the use of a specialized algorithm that systematically determines regions of interest inside the 10 x 10 cm2 exposure areas to manually selected regions of interest. There was a maximum difference of only 0.07% between the manually and automatically selected regions, indicating that the use of a systematic algorithm to determine regions of interest in large and fairly uniform areas is not necessary. Based on these results, we recommend a minimum time of 1 h between exposure and processing for all EDR2 film measurements.

  15. Analyses of surface coloration on TiO 2 film irradiated with excimer laser

    NASA Astrophysics Data System (ADS)

    Zheng, H. Y.; Qian, H. X.; Zhou, W.

    2008-01-01

    TiO 2 film of around 850 nm in thickness was deposited on a soda-lime glass by PVD sputtering and irradiated using one pulse of krypton-fluorine (KrF) excimer laser (wavelength of 248 nm and pulse duration of 25 ns) with varying fluence. The color of the irradiated area became darker with increasing laser fluence. Irradiated surfaces were characterized using optical microscopy, scanning electron microscopy, Raman spectroscopy and atomic force microscopy. Surface undergoes thermal annealing at low laser fluence of 400 and 590 mJ/cm 2. Microcracks at medium laser fluence of 1000 mJ/cm 2 are attributed to surface melting and solidification. Hydrodynamic ablation is proposed to explain the formation of micropores and networks at higher laser fluence of 1100 and 1200 mJ/cm 2. The darkening effect is explained in terms of trapping of light in the surface defects formed rather than anatase to rutile phase transformation as reported by others. Controlled darkening of TiO 2 film might be used for adjustable filters.

  16. Large area, surface discharge pumped, vacuum ultraviolet light source

    DOEpatents

    Sze, R.C.; Quigley, G.P.

    1996-12-17

    Large area, surface discharge pumped, vacuum ultraviolet (VUV) light source is disclosed. A contamination-free VUV light source having a 225 cm{sup 2} emission area in the 240-340 nm region of the electromagnetic spectrum with an average output power in this band of about 2 J/cm{sup 2} at a wall-plug efficiency of approximately 5% is described. Only ceramics and metal parts are employed in this surface discharge source. Because of the contamination-free, high photon energy and flux, and short pulse characteristics of the source, it is suitable for semiconductor and flat panel display material processing. 3 figs.

  17. Large area silicon sheet by EFG

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Recent advances toward silicon growth stations and improved electronic quality of multiplesilicon are discussed. These advances were made in large measure by studies in which the composition of the gas environment around the meniscus area was varied. By introducing gases such as CO2, CO, and CH4 into this region, reproducible increases in diffusion length and cell performance were realized, with the best large area (5 cm x 10 cm) cells exceeding 11% efficiency.

  18. 3D Printing of Preoperative Simulation Models of a Splenic Artery Aneurysm: Precision and Accuracy.

    PubMed

    Takao, Hidemasa; Amemiya, Shiori; Shibata, Eisuke; Ohtomo, Kuni

    2017-05-01

    Three-dimensional (3D) printing is attracting increasing attention in the medical field. This study aimed to apply 3D printing to the production of hollow splenic artery aneurysm models for use in the simulation of endovascular treatment, and to evaluate the precision and accuracy of the simulation model. From 3D computed tomography (CT) angiography data of a splenic artery aneurysm, 10 hollow models reproducing the vascular lumen were created using a fused deposition modeling-type desktop 3D printer. After filling with water, each model was scanned using T2-weighted magnetic resonance imaging for the evaluation of the lumen. All images were coregistered, binarized, and then combined to create an overlap map. The cross-sectional area of the splenic artery aneurysm and its standard deviation (SD) were calculated perpendicular to the x- and y-axes. Most voxels overlapped among the models. The cross-sectional areas were similar among the models, with SDs <0.05 cm 2 . The mean cross-sectional areas of the splenic artery aneurysm were slightly smaller than those calculated from the original mask images. The maximum mean cross-sectional areas calculated perpendicular to the x- and y-axes were 3.90 cm 2 (SD, 0.02) and 4.33 cm 2 (SD, 0.02), whereas those calculated from the original mask images were 4.14 cm 2 and 4.66 cm 2 , respectively. The mean cross-sectional areas of the afferent artery were, however, almost the same as those calculated from the original mask images. The results suggest that 3D simulation modeling of a visceral artery aneurysm using a fused deposition modeling-type desktop 3D printer and computed tomography angiography data is highly precise and accurate. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  19. Rapid culture-independent microbial analysis aboard the International Space Station (ISS).

    PubMed

    Maule, Jake; Wainwright, Norm; Steele, Andrew; Monaco, Lisa; Morris, Heather; Gunter, Daniel; Damon, Michael; Wells, Mark

    2009-10-01

    A new culture-independent system for microbial monitoring, called the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS), was operated aboard the International Space Station (ISS). LOCAD-PTS was launched to the ISS aboard Space Shuttle STS-116 on December 9, 2006, and has since been used by ISS crews to monitor endotoxin on cabin surfaces. Quantitative analysis was performed within 15 minutes, and sample return to Earth was not required. Endotoxin (a marker of Gram-negative bacteria) was distributed throughout the ISS, despite previous indications that mostbacteria on ISS surfaces were Gram-positive [corrected].Endotoxin was detected at 24 out of 42 surface areas tested and at every surface site where colony-forming units (cfu) were observed, even at levels of 4-120 bacterial cfu per 100 cm(2), which is below NASA in-flight requirements (<10,000 bacterial cfu per 100 cm(2)). Absent to low levels of endotoxin (<0.24 to 1.0 EU per 100 cm(2); defined in endotoxin units, or EU) were found on 31 surface areas, including on most panels in Node 1 and the US Lab. High to moderate levels (1.01 to 14.7 EU per 100 cm(2)) were found on 11 surface areas, including at exercise, hygiene, sleeping, and dining facilities. Endotoxin was absent from airlock surfaces, except the Extravehicular Hatch Handle (>3.78 EU per 100 cm(2)). Based upon data collected from the ISS so far, new culture-independent requirements (defined in EU) are suggested, which are verifiable in flight with LOCAD-PTS yet high enough to avoid false alarms. The suggested requirements are intended to supplement current ISS requirements (defined in cfu) and would serve a dual purpose of safeguarding crew health (internal spacecraft surfaces <20 EU per 100 cm(2)) and monitoring forward contamination during Constellation missions (surfaces periodically exposed to the external environment, including the airlock and space suits, <0.24 EU per 100 cm(2)).

  20. Rapid Culture-Independent Microbial Analysis Aboard the International Space Station (ISS)

    NASA Astrophysics Data System (ADS)

    Maule, Jake; Wainwright, Norm; Steele, Andrew; Monaco, Lisa; Morris, Heather; Gunter, Daniel; Damon, Michael; Wells, Mark

    2009-10-01

    A new culture-independent system for microbial monitoring, called the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS), was operated aboard the International Space Station (ISS). LOCAD-PTS was launched to the ISS aboard Space Shuttle STS-116 on December 9, 2006, and has since been used by ISS crews to monitor endotoxin on cabin surfaces. Quantitative analysis was performed within 15 minutes, and sample return to Earth was not required. Endotoxin (a marker of Gram-negative bacteria and fungi) was distributed throughout the ISS, despite previous indications that most bacteria on ISS surfaces were Gram-positive. Endotoxin was detected at 24 out of 42 surface areas tested and at every surface site where colony-forming units (cfu) were observed, even at levels of 4-120 bacterial cfu per 100 cm2, which is below NASA in-flight requirements (<10,000 bacterial cfu per 100 cm2). Absent to low levels of endotoxin (<0.24 to 1.0 EU per 100 cm2; defined in endotoxin units, or EU) were found on 31 surface areas, including on most panels in Node 1 and the US Lab. High to moderate levels (1.01 to 14.7 EU per 100 cm2) were found on 11 surface areas, including at exercise, hygiene, sleeping, and dining facilities. Endotoxin was absent from airlock surfaces, except the Extravehicular Hatch Handle (>3.78 EU per 100 cm2). Based upon data collected from the ISS so far, new culture-independent requirements (defined in EU) are suggested, which are verifiable in flight with LOCAD-PTS yet high enough to avoid false alarms. The suggested requirements are intended to supplement current ISS requirements (defined in cfu) and would serve a dual purpose of safeguarding crew health (internal spacecraft surfaces <20 EU per 100 cm2) and monitoring forward contamination during Constellation missions (surfaces periodically exposed to the external environment, including the airlock and space suits, <0.24 EU per 100 cm2).

  1. Large area Czochralski silicon

    NASA Technical Reports Server (NTRS)

    Rea, S. N.; Gleim, P. S.

    1977-01-01

    The overall cost effectiveness of the Czochralski process for producing large-area silicon was determined. The feasibility of growing several 12 cm diameter crystals sequentially at 12 cm/h during a furnace run and the subsequent slicing of the ingot using a multiblade slurry saw were investigated. The goal of the wafering process was a slice thickness of 0.25 mm with minimal kerf. A slice + kerf of 0.56 mm was achieved on 12 cm crystal using both 400 grit B4C and SiC abrasive slurries. Crystal growth experiments were performed at 12 cm diameter in a commercially available puller with both 10 and 12 kg melts. Several modifications to the puller hoz zone were required to achieve stable crystal growth over the entire crystal length and to prevent crystallinity loss a few centimeters down the crystal. The maximum practical growth rate for 12 cm crystal in this puller design was 10 cm/h, with 12 to 14 cm/h being the absolute maximum range at which melt freeze occurred.

  2. The effect of curcumin and its nanoformulation on adjuvant-induced arthritis in rats.

    PubMed

    Zheng, Zhaoling; Sun, YanHua; Liu, Ziliang; Zhang, Mingqin; Li, Chunqing; Cai, Hui

    2015-01-01

    Rheumatoid arthritis (RA), induced by the prolonged inappropriate inflammatory responses, is one of the most prevalent of all chronic inflammatory joint diseases. Curcumin (CM), a yellow hydrophobic polyphenol derived from the herb turmeric, has various pharmacological activities against many chronic diseases and acts by inhibiting cell proliferation and metastasis and downregulating various factors, including nuclear factor kappa B, interleukin-1β and TNF-α. Given the pathogenesis of RA, we hypothesized that the drug also has antiarthritic effects. The aims of the present study included the following: 1) examining the therapeutic effect of CM administered via intravenous (iv) injection on RA and 2) formulating the drug into oil-water nanoemulsions (Ns) to overcome the low oral bioavailability of CM and achieve oral delivery of the drug. The effect of CM administered through iv injection on adjuvant-induced arthritis in rats was studied in terms of paw swelling, weight indices of the thymus and spleen, and pathological changes in nuclear factor kappa B expression and inflammatory cytokines. Methotrexate was used as a positive control. The CM-Ns were prepared using a high-pressure homogenizing method and characterized with respect to the particle size and morphology. The stability of the CM-Ns in simulated gastrointestinal (GI) fluids and in vitro release were also investigated. A pharmacokinetic study of the CM-Ns and suspensions in which the plasma levels were determined using an high performance liquid chromatography method and the pharmacokinetic parameters were calculated based on a statistical moment theory was also performed in rats. CM administered via iv injection had a therapeutic effect on RA similar to methotrexate. CM-Ns with a diameter of approximately 150 nm were successfully prepared, and the drug was well encapsulated into the Ns without degradation in simulated GI conditions. The area under the curve (AUC) and Cmax for the CM-Ns were more than threefold greater than those for the suspensions; moreover, similar decreases in the levels of TNF-α and interleukin-1β in both synovial fluid and blood serum were obtained from oral administration of CM-Ns and iv injection. CM was an effective antiarthritic agent, and the present N formulation appeared to be a promising system that allowed RA therapy with CM to be converted from iv to oral administration.

  3. Geographically correlated errors observed from a laser-based short-arc technique

    NASA Astrophysics Data System (ADS)

    Bonnefond, P.; Exertier, P.; Barlier, F.

    1999-07-01

    The laser-based short-arc technique has been developed in order to avoid local errors which affect the dynamical orbit computation, such as those due to mismodeling in the geopotential. It is based on a geometric method and consists in fitting short arcs (about 4000 km), issued from a global orbit, with satellite laser ranging tracking measurements from a ground station network. Ninety-two TOPEX/Poseidon (T/P) cycles of laser-based short-arc orbits have then been compared to JGM-2 and JGM-3 T/P orbits computed by the Precise Orbit Determination (POD) teams (Service d'Orbitographie Doris/Centre National d'Etudes Spatiales and Goddard Space Flight Center/NASA) over two areas: (1) the Mediterranean area and (2) a part of the Pacific (including California and Hawaii) called hereafter the U.S. area. Geographically correlated orbit errors in these areas are clearly evidenced: for example, -2.6 cm and +0.7 cm for the Mediterranean and U.S. areas, respectively, relative to JGM-3 orbits. However, geographically correlated errors (GCE) which are commonly linked to errors in the gravity model, can also be due to systematic errors in the reference frame and/or to biases in the tracking measurements. The short-arc technique being very sensitive to such error sources, our analysis however demonstrates that the induced geographical systematic effects are at the level of 1-2 cm on the radial orbit component. Results are also compared with those obtained with the GPS-based reduced dynamic technique. The time-dependent part of GCE has also been studied. Over 6 years of T/P data, coherent signals in the radial component of T/P Precise Orbit Ephemeris (POE) are clearly evidenced with a time period of about 6 months. In addition, impact of time varying-error sources coming from the reference frame and the tracking data accuracy has been analyzed, showing a possible linear trend of about 0.5-1 mm/yr in the radial component of T/P POE.

  4. Combined Study of Snow Depth Determination and Winter Leaf Area Index Retrieval by Unmanned Aerial Vehicle Photogrammetry

    NASA Astrophysics Data System (ADS)

    Lendzioch, Theodora; Langhammer, Jakub; Jenicek, Michal

    2017-04-01

    A rapid and robust approach using Unmanned Aerial Vehicle (UAV) digital photogrammetry was performed for evaluating snow accumulation over different small localities (e.g. disturbed forest and open area) and for indirect field measurements of Leaf Area Index (LAI) of coniferous forest within the Šumava National Park, Czech Republic. The approach was used to reveal impacts related to changes in forest and snowpack and to determine winter effective LAI for monitoring the impact of forest canopy metrics on snow accumulation. Due to the advancement of the technique, snow depth and volumetric changes of snow depth over these selected study areas were estimated at high spatial resolution (1 cm) by subtracting a snow-free digital elevation model (DEM) from a snow-covered DEM. Both, downward-looking UAV images and upward-looking digital hemispherical photography (DHP), and additional widely used LAI-2200 canopy analyser measurements were applied to determine the winter LAI, controlling interception and transmitting radiation. For the performance of downward-looking UAV images the snow background instead of the sky fraction was used. The reliability of UAV-based LAI retrieval was tested by taking an independent data set during the snow cover mapping campaigns. The results showed the potential of digital photogrammetry for snow depth mapping and LAI determination by UAV techniques. The average difference obtained between ground-based and UAV-based measurements of snow depth was 7.1 cm with higher values obtained by UAV. The SD of 22 cm for the open area seemed competitive with the typical precision of point measurements. In contrast, the average difference in disturbed forest area was 25 cm with lower values obtained by UAV and a SD of 36 cm, which is in agreement with other studies. The UAV-based LAI measurements revealed the lowest effective LAI values and the plant canopy analyser LAI-2200 the highest effective LAI values. The biggest bias of effective LAI was observed between LAI-2200 and UAV-based analyses. Since the LAI parameter is important for snowpack modelling, this method presents the potential of simplifying LAI retrieval and mapping of snow dynamics while reducing running costs and time.

  5. Do transmitters affect survival and body condition of American beavers Castor canadensis?

    USGS Publications Warehouse

    Smith, Joshua B.; Windels, Steve K.; Wolf, Tiffany; Klaver, Robert W.; Belant, Jerrold L.

    2016-01-01

    One key assumption often inferred with using radio-equipped individuals is that the transmitter has no effect on the metric of interest. To evaluate this assumption, we used a known fate model to assess the effect of transmitter type (i.e. tail-mounted or peritoneal implant) on short-term (one year) survival and a joint live—dead recovery model and results from a mark—recapture study to compare long-term (eight years) survival and body condition of ear-tagged only American beavers Castor canadensis to those equipped with radio transmitters in Voyageurs National Park, Minnesota, USA. Short-term (1-year) survival was not influenced by transmitter type (wi = 0.64). Over the 8-year study period, annual survival was similar between transmitter-equipped beavers (tail-mounted and implant transmitters combined; 0.76; 95% CI = 0.45–0.91) versus ear-tagged only (0.78; 95% CI = 0.45–0.93). Additionally, we found no difference in weight gain (t9 = 0.25, p = 0.80) or tail area (t11 = 1.25, p = 0.24) from spring to summer between the two groups. In contrast, winter weight loss (t22 = - 2.03, p = 0.05) and tail area decrease (t30 = - 3.04, p = 0.01) was greater for transmitterequipped (weight = - 3.09 kg, SE = 0.55; tail area = - 33.71 cm2, SE = 4.80) than ear-tagged only (weight = - 1.80 kg, SE = 0.33; tail area = - 12.38 cm2, SE = 5.13) beavers. Our results generally support the continued use of transmitters on beavers for estimating demographic parameters, although we recommend additional assessments of transmitter effects under different environmental conditions.

  6. The use of optical fiber in endodontic photodynamic therapy. Is it really relevant?

    PubMed

    Garcez, Aguinaldo S; Fregnani, Eduardo R; Rodriguez, Helena M; Nunez, Silvia C; Sabino, Caetano P; Suzuki, Hideo; Ribeiro, Martha S

    2013-01-01

    This study analyzed the necessity of use of an optical fiber/diffusor when performing antimicrobial photodynamic therapy (PDT) associated with endodontic therapy. Fifty freshly extracted human single-rooted teeth were used. Conventional endodontic treatment was performed using a sequence of ProTaper (Dentsply Maillefer Instruments), the teeth were sterilized, and the canals were contaminated with Enterococcus faecalis 3 days' biofilm. The samples were divided into five groups: group 1--ten roots irradiated with a laser tip (area of 0.04 cm(2)), group 2--ten roots irradiated with a smaller laser tip (area of 0.028 cm(2)), and group 3--ten teeth with the crown, irradiate with the laser tip with 0.04 cm(2) of area. The forth group (G4) followed the same methodology as group 3, but the irradiation was performed with smaller tip (area of 0.028 cm(2)) and G5 ten teeth with crown were irradiated using a 200-mm-diameter fiber/diffusor coupled to diode laser. Microbiological samples were taken after accessing the canal, after endodontic therapy, and after PDT. Groups 1 and 2 showed a reduction of two logs (99%), groups 3 and 4 of one log (85% and 97%, respectively), and group 5 of four logs (99.99%). Results suggest that the use of PDT added to endodontic treatment in roots canals infected with E. faecalis with the optical fiber/diffusor is better than when the laser light is used directed at the access of cavity.

  7. 16 CFR 500.19 - Conversion of SI metric quantities to inch/pound quantities and inch/pound quantities to SI...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... centimeter=0.393 701 in. 1 yard=0.9144m* 1 meter=3.280 84 ft. Area 1 square inch=6.4516 cm2* 1 square centimeter=0.155 000 in2. 1 square foot=929.0304 cm2* 1 square decimeter=0.107 639 ft2. =9.290 304 dm2 1 square meter=10.763 9 ft2. 1 square yard=0.836 127 m2 Volume or Capacity 1 cubic inch=16.3871 cm3 1 cubic...

  8. 16 CFR 500.19 - Conversion of SI metric quantities to inch/pound quantities and inch/pound quantities to SI...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... centimeter=0.393 701 in. 1 yard=0.9144m* 1 meter=3.280 84 ft. Area 1 square inch=6.4516 cm2* 1 square centimeter=0.155 000 in2. 1 square foot=929.0304 cm2* 1 square decimeter=0.107 639 ft2. =9.290 304 dm2 1 square meter=10.763 9 ft2. 1 square yard=0.836 127 m2 Volume or Capacity 1 cubic inch=16.3871 cm3 1 cubic...

  9. 16 CFR 500.19 - Conversion of SI metric quantities to inch/pound quantities and inch/pound quantities to SI...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... centimeter=0.393 701 in. 1 yard=0.9144m* 1 meter=3.280 84 ft. Area 1 square inch=6.4516 cm2* 1 square centimeter=0.155 000 in2. 1 square foot=929.0304 cm2* 1 square decimeter=0.107 639 ft2. =9.290 304 dm2 1 square meter=10.763 9 ft2. 1 square yard=0.836 127 m2 Volume or Capacity 1 cubic inch=16.3871 cm3 1 cubic...

  10. 16 CFR 500.19 - Conversion of SI metric quantities to inch/pound quantities and inch/pound quantities to SI...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... centimeter=0.393 701 in. 1 yard=0.9144m* 1 meter=3.280 84 ft. Area 1 square inch=6.4516 cm2* 1 square centimeter=0.155 000 in2. 1 square foot=929.0304 cm2* 1 square decimeter=0.107 639 ft2. =9.290 304 dm2 1 square meter=10.763 9 ft2. 1 square yard=0.836 127 m2 Volume or Capacity 1 cubic inch=16.3871 cm3 1 cubic...

  11. [Aesthetic effect of wound repair with flaps].

    PubMed

    Tan, Qian; Zhou, Hong-Reng; Wang, Shu-Qin; Zheng, Dong-Feng; Xu, Peng; Wu, Jie; Ge, Hua-Qiang; Lin, Yue; Yan, Xin

    2012-08-01

    To investigate the aesthetic effect of wound repair with flaps. One thousand nine hundred and ninety-six patients with 2082 wounds hospitalized from January 2004 to December 2011. These wounds included 503 deep burn wounds, 268 pressure sores, 392 soft tissue defects caused by trauma, 479 soft tissue defects due to resection of skin cancer and mole removal, 314 soft tissue defects caused by scar excision, and 126 other wounds. Wound area ranged from 1.5 cm x 1.0 cm to 30.0 cm x 22.0 cm. Sliding flaps, expanded flaps, pedicle flaps, and free flaps were used to repair the wounds in accordance with the principle and timing of wound repair with flaps. Five flaps showed venous congestion within 48 hours post-operation, 2 flaps of them improved after local massage. One flap survived after local heparin wet packing and venous bloodletting. One flap survived after emergency surgical embolectomy and bridging with saphenous vein graft. One flap showed partial necrosis and healed after skin grafting. The other flaps survived well. One thousand three hundred and twenty-one patients were followed up for 3 months to 2 years, and flaps of them were satisfactory in shape, color, and elasticity, similar to that of normal skin. Some patients underwent scar revision later with good results. Application of suitable flaps in wound repair will result in quick wound healing, good function recovery, and satisfactory aesthetic effect.

  12. Actinic defect counting statistics over 1-cm2 area of EUVL mask blank

    NASA Astrophysics Data System (ADS)

    Jeong, Seongtae; Lai, Chih-wei; Rekawa, Senajith; Walton, Christopher C.; Bokor, Jeffrey

    2000-07-01

    As a continuation of comparison experiments between EUV inspection and visible inspection of defects on EUVL mask blanks, we report on the result of an experiment where the EUV defect inspection tool is used to perform at-wavelength defect counting over 1 cm2 of EUVL mask blank. Initial EUV inspection found five defects over the scanned area and the subsequent optical scattering inspection was able to detect all of the five defects. Therefore, if there are any defects that are only detectable by EUV inspection, the density is lower than the order of unity per cm2. An upgrade path to substantially increase the overall throughput of the EUV inspection system is also identified in the manuscript.

  13. The radiation dose from a proposed measurement of arsenic and selenium in human skin

    NASA Astrophysics Data System (ADS)

    Gherase, Mihai R.; Mader, Joanna E.; Fleming, David E. B.

    2010-09-01

    Dose measurements following 10 min irradiations with a portable x-ray fluorescence spectrometer composed of a miniature x-ray tube and a silicon PiN diode detector were performed using thermoluminescent dosimeters consisting of LiF:Mg,Ti chips of 3 mm diameter and 0.4 mm thickness. The table-top setup of the spectrometer was used for all measurements. The setup included a stainless steel lid which served as a radiation shield. Two rectangular polyethylene skin/soft tissue phantoms with two cylindrical plaster of Paris bone phantoms were used to study the effect of x-ray beam attenuation and backscatter on the measured dose. Eight different irradiation experiments were performed. The average dose rate values measured with TLD chips within a 1 × 1 cm2 area were between 4.8 and 12.8 mGy min-1. The equivalent dose for a 1 × 1 cm2 skin area was estimated to be 13.2 mSv. The maximum measured dose rate values with a single TLD chip were between 7.5 and 25.1 mGy min-1. The effective dose corresponding to a proposed arsenic/selenium skin measurement was estimated to be 0.13 µSv for a 2 min irradiation.

  14. Current density and catalyst-coated membrane resistance distribution of hydro-formed metallic bipolar plate fuel cell short stack with 250 cm2 active area

    NASA Astrophysics Data System (ADS)

    Haase, S.; Moser, M.; Hirschfeld, J. A.; Jozwiak, K.

    2016-01-01

    An automotive fuel cell with an active area of 250 cm2 is investigated in a 4-cell short stack with a current and temperature distribution device next to the bipolar plate with 560 current and 140 temperature segments. The electrical conductivities of the bipolar plate and gas diffusion layer assembly are determined ex-situ with this current scan shunt module. The applied fuel cell consists of bipolar plates constructed of 75-μm-thick, welded stainless-steel foils and a graphitic coating. The electrical conductivities of the bipolar plate and gas diffusion layer assembly are determined ex-situ with this module with a 6% deviation in in-plane conductivity. The current density distribution is evaluated up to 2.4 A cm-2. The entire cell's investigated volumetric power density is 4.7 kW l-1, and its gravimetric power density is 4.3 kW kg-1 at an average cell voltage of 0.5 V. The current density distribution is determined without influencing the operating cell. In addition, the current density distribution in the catalyst-coated membrane and its effective resistivity distribution with a finite volume discretisation of Ohm's law are evaluated. The deviation between the current density distributions in the catalyst-coated membrane and the bipolar plate is determined.

  15. Optimized delivery of skin keratinocytes by aerosolization and suspension in fibrin tissue adhesive.

    PubMed

    Harkin, Damien G; Dawson, Rebecca A; Upton, Zee

    2006-01-01

    Aerosolized suspensions of keratinocytes provide a potential therapy for wounds, but the effects of aerosolization on cell viability remain unclear. Likewise, little is known of the resulting cell distribution pattern and how this compares to the density required for epithelialization. The potential benefits of cospraying cells in the presence of fibrin adhesive are equally uncertain. Thus, in the present study we have optimized conditions for the aerosolization of cultured keratinocytes using a device (Tissomat) that supports the option for coapplication with fibrin (Tisseel). Cell viability was unaffected when sprayed at 10 psi, but a significant reduction in metabolic activity, as determined by the methylthiazoyldiphenol-tetrazolium assay, was observed at higher pressure. Bursts of 0.2 mL cell suspension (1.5x10(6)/mL) delivered from a height of 10 cm was sufficient to epithelialize an area of 10-15 cm2 within 7 days in vitro. Confluent areas corresponded to those with a density of 5,000-10,000 cells/cm2 at 24 hours. Optimal cell growth in Tisseel was achieved through dilution of fibrinogen (1-3 mg/mL) and thrombin (2-5 IU/mL). This optimized formulation eliminated fluid run-off postspraying and stimulated a twofold increase in cellular response. Therefore, our in vitro data supports the theory that aerosolized suspensions of keratinocytes in fibrin will benefit healing.

  16. The Effect of Various Oral Hygiene Products on Bacterial Growth

    NASA Astrophysics Data System (ADS)

    Viswanath, S.; Aggrawal, A.; Vazirani, S.

    2017-12-01

    In this experiment, we tested the antimicrobial effectiveness of six different oral hygiene products. We used three natural cleansing products (coconut oil, sea salt, and baking soda), as well as three synthetic products, which were the Colgate toothpaste varieties of sensitivity, cavity protection, and whitening. We mixed water with each of the products to create a paste that could be uniformly applied to the surface of a disc. We then dipped the discs into the solutions and placed them in petri dishes that were pre-treated with bacterial cells. After 72 hours, we measured the area around the disc that was bacteria-free, which is known as the zone of inhibition. This experiment was repeated twice, with one petri dish per product for each trial, and two different types of agar. We were surprised to discover that almost all the products had no zone of inhibition, with bacteria growing throughout the petri dish, and to the disc. The only cleaning product that showed a significant antibacterial result was the Colgate sensitivity toothpaste. During the two trials, the sensitivity toothpaste had a zone of inhibition of 14.8 cm2 and 8.7 cm2, respectively. Coconut oil was the only other product to have a measurable zone of inhibition with an area of 0.3 cm2. We concluded that only the sensitivity toothpaste was effective in killing bacteria, perhaps due to its different hygienic goal of protecting the tooth's nerves. This toothpaste contains ingredients called potassium nitrate and strontium chloride, which blocks tubules in the dentin, the hard, bony tissue beneath the enamel. Sensitivity toothpaste strengthens the tooth, by blocking decaying substances such as oral bacteria (Knights, 2014).

  17. Managing an invasive corallimorph at Palmyra Atoll National Wildlife Refuge, Line Islands, Central Pacific

    USGS Publications Warehouse

    Work, Thierry M.; Aeby, Greta S.; Neal, Benjamin P.; Price, Nichole N.; Conklin, Eric; Pollock, Amanda

    2018-01-01

    In 2007, a phase shift from corals to corallimorpharians (CM) centered around a shipwreck was documented at Palmyra Atoll, Line Islands. Subsequent surveys revealed CM to be overgrowing the reef benthos, including corals and coralline algae, potentially placing coral ecosystems in the atoll at risk. This prompted the U.S. Fish and Wildlife Service, the lead management agency of the atoll, to remove the shipwreck. Subsequent surveys showed reductions in CM around the ship impact site. We explain patterns of spread of the CM in terms of both life history and local currents and show with a pilot study that pulverized bleach may be an effective tool to eradicate CM on a local scale. If applied strategically, particularly in heavily infested (> 66% cover) areas, active intervention such as this could be an effective management tool to reduce CM impact on localized areas and decrease colonization rate of remaining reefs. This is the first documentation of the response of an invasive cnidarian to shipwreck removal. While this was a singular event in Palmyra, the spatial and temporal patterns of this invasion and the eradications lessons described herein, are useful for anticipating and controlling similar situations elsewhere.

  18. Error rate of automated calculation for wound surface area using a digital photography.

    PubMed

    Yang, S; Park, J; Lee, H; Lee, J B; Lee, B U; Oh, B H

    2018-02-01

    Although measuring would size using digital photography is a quick and simple method to evaluate the skin wound, the possible compatibility of it has not been fully validated. To investigate the error rate of our newly developed wound surface area calculation using digital photography. Using a smartphone and a digital single lens reflex (DSLR) camera, four photographs of various sized wounds (diameter: 0.5-3.5 cm) were taken from the facial skin model in company with color patches. The quantitative values of wound areas were automatically calculated. The relative error (RE) of this method with regard to wound sizes and types of camera was analyzed. RE of individual calculated area was from 0.0329% (DSLR, diameter 1.0 cm) to 23.7166% (smartphone, diameter 2.0 cm). In spite of the correction of lens curvature, smartphone has significantly higher error rate than DSLR camera (3.9431±2.9772 vs 8.1303±4.8236). However, in cases of wound diameter below than 3 cm, REs of average values of four photographs were below than 5%. In addition, there was no difference in the average value of wound area taken by smartphone and DSLR camera in those cases. For the follow-up of small skin defect (diameter: <3 cm), our newly developed automated wound area calculation method is able to be applied to the plenty of photographs, and the average values of them are a relatively useful index of wound healing with acceptable error rate. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Effect of the laser and light-emitting diode (LED) phototherapy on midpalatal suture bone formation after rapid maxilla expansion: a Raman spectroscopy analysis.

    PubMed

    Rosa, Cristiane Becher; Habib, Fernando Antonio Lima; de Araújo, Telma Martins; Aragão, Juliana Silveira; Gomes, Rafael Soares; Barbosa, Artur Felipe Santos; Silveira, Landulfo; Pinheiro, Antonio L B

    2014-05-01

    The aim of this study was to analyze the effect of laser or light-emitting diode (LED) phototherapy on the bone formation at the midpalatal suture after rapid maxilla expansion. Twenty young adult male rats were divided into four groups with 8 days of experimental time: group 1, no treatment; group 2, expansion; group 3, expansion and laser irradiation; and group 4, expansion and LED irradiation. In groups 3 and 4, light irradiation was in the first, third, and fifth experimental days. In all groups, the expansion was accomplished with a helicoid 0.020" stainless steel orthodontic spring. A diode laser (λ780 nm, 70 mW, spot of 0.04 cm(2), t = 257 s, spatial average energy fluence (SAEF) of 18 J/cm(2)) or a LED (λ850 nm, 150 mW ± 10 mW, spot of 0.5 cm(2), t = 120 s, SAEF of 18 J/cm(2)) were used. The samples were analyzed by Raman spectroscopy carried out at midpalatal suture and at the cortical area close to the suture. Two Raman shifts were analyzed: ∼ 960 (phosphate hydroxyapatite) and ∼ 1,450 cm(-1) (lipids and protein). Data was submitted to statistical analysis. Significant statistical difference (p ≤ 0.05) was found in the hydroxyapatite (CHA) peaks among the expansion group and the expansion and laser or LED groups. The LED group presented higher mean peak values of CHA. No statistical differences were found between the treated groups as for collagen deposition, although LED also presented higher mean peak values. The results of this study using Raman spectral analysis indicate that laser and LED light irradiation improves deposition of CHA in the midpalatal suture after orthopedic expansion.

  20. Biologics formulation factors affecting metal leachables from stainless steel.

    PubMed

    Zhou, Shuxia; Schöneich, Christian; Singh, Satish K

    2011-03-01

    An area of increasing concern and scientific scrutiny is the potential contamination of drug products by leachables entering the product during manufacturing and storage. These contaminants may either have a direct safety impact on the patients or act indirectly through the alteration of the physicochemical properties of the product. In the case of biotherapeutics, trace amounts of metal contaminants can arise from various sources, but mainly from contact with stainless steel (ss). The effect of the various factors, buffer species, solution fill volume per unit contact surface area, metal chelators, and pH, on metal leachables from contact with ss over time were investigated individually. Three major metal leachables, iron, chromium, and nickel, were monitored by inductively coupled plasma-mass spectrometry because they are the major components of 316L ss. Iron was primarily used to evaluate the effect of each factor since it is the most abundant. It was observed that each studied factor exhibited its own effect on metal leachables from contact with ss. The effect of buffer species and pH exhibited temperature dependence over the studied temperature range. The metal leachables decreased with the increased fill volume (mL) per unit contact ss surface area (cm(2)) but a plateau was achieved at approximately 3 mL/cm(2). Metal chelators produced the strongest effect in facilitating metal leaching. In order to minimize the metal leachables and optimize biological product stability, each formulation factor must be evaluated for its impact, to balance its risk and benefit in achieving the target drug product shelf life. © 2011 American Association of Pharmaceutical Scientists

  1. Experimental determination of drag coefficients in low-density polyurethane foam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, M L

    2006-04-18

    We describe several experiments performed at the LLNL Site 300 firing range and on the LLNL 1/3 scale gun to investigate the deceleration of small projectiles (l {approx} 3-5 [mm]) in low-density foam ({rho} {approx} 0.08-0.32 [g/cm{sup 3}]). The experiments at the firing range researched a passive velocity diagnostic based on Faraday's law of induction, while experiments on the 1/3 scale gun investigated the effects of varying projectile surface area, projectile shape, and foam density on the drag coefficient c{sub d}. Analysis shows that the velocity diagnostic has an uncertainty on the order of 1 percent for projectiles with velocitymore » v {approx} 0.8-1.2 [km/s]. The 1/3 scale gun experiments, dubbed the Krispy Kreme series, included nine shots considering the combinations of 3 projectile surface areas with 3 target densities. The experiments used Tantalum square surface area block projectiles (with an initial velocity v{sub 0} {approx} 1.2 [km/s], a common thickness T = 2.67 [mm], and square side lengths of 3, 4, and 5 [mm]) decelerating in polyurethane foams (with densities {rho}{sub f} of 0.08, 0.16 and 0.32 [g/cm{sup 3}]). Standard fluid models of the Krispy Kreme experiments predict Reynolds numbers Re {approx} 10{sup 5} - 10{sup 6}, Mach numbers Ma {approx} 0.5-2.0, and drag coefficients c{sub d} {approx} 2-3. However, the data indicate that c{sub d} = 1.1-1.2 (c{sub d} = 1.7) for all three block projectiles in the 0.08 and 0.16 [g/cm{sup 3}] targets (0.32 [g/cm{sup 3}] target). First, we conclude that the drag force on projectiles in solid polyurethane foam is less than in fluids with equivalent dimensionless parameters. This result is also supported by an additional Krispy Kreme experiment that used a disk projectile (with diameter d = 4.51 [mm] and thickness T = 2.67 [mm]) penetrating a target with density {rho} = 0.16 [g/cm{sup 3}], i.e., the fluid-like c{sub d} = 1.15 while the measured c{sub d} = 0.63. Second, we conclude that the measured drag coefficient in the lower density foam targets is less than in the larger density foam target. This result is corroborated by firing range experiments with M855 NATO bullets (with diameter 5.56 [mm], mass 4.1 [g], and initial velocity {nu}{sub 0} {approx} 800 [m/s]) fired from an M16 rifle, i.e., c{sub d} = 0.3 (c{sub d} = 0.6) in the 0.16 [g/cm{sup 3}] (0.32 [g/cm{sup 3}]) target. We propose future 1/3 scale gun experiments using a passive velocity diagnostic with increased spatial resolution as well as simple spherical projectiles with 0.5 and 1.0 [cm] diameters.« less

  2. Effects of different hydrostatic pressure on lesions in ex vivo bovine livers induced by high intensity focused ultrasound.

    PubMed

    He, Min; Zhong, Zhiqiang; Li, Xing; Gong, Xiaobo; Wang, Zhibiao; Li, Faqi

    2017-05-01

    It is well-known that acoustic cavitation associated with the high intensity focused ultrasound (HIFU) treatment often would change the morphology and size of lesions in its treatment. In most studies reported in literature, high ambient hydrostatic pressure was used to suppress the cavitation completely. Investigation of the effects by varying the ambient hydrostatic pressure (P stat ) is still lacking. In this paper, the effects of HIFU on lesions in ex vivo bovine liver specimens under various P stat are systematically investigated. A 1MHz HIFU transducer, with an aperture diameter of 70mm and a focal length of 55mm, was used to generate two groups US exposure of different acoustic intensities and exposure time (6095W/cm 2 ×8s and 9752W/cm 2 ×5s), while keeping the same acoustic energies per unit area (48760J/cm 2 ). The peak acoustic negative pressures (p - ) of the two groups were p 1 - =9.58MPa and p 2 - =10.82MPa, respectively, with the difference p d - =p 2 - -p 1 - =1.24MPa. A passive cavitation detection (PCD) was used to monitor the ultrasonic cavitation signal during exposure of the two groups. The US exposures were done under the following ambient hydrostatic pressures, P stat : atmospheric pressure, 0.5MPa, 1.0MPa, 1.5MPa, 2.0MPa, 2.5MPa and3.0MPa, respectively. The result of PCD showed that there was a statistically significant increase above background noise level in broadband emissions at dose of 9752W/cm 2 ×5s, but not at dose of 6095W/cm 2 ×8s under atmospheric pressure; i.e., the acoustic cavitation took place for p 2 - but not for p 1 - when under atmospheric pressure. The results also showed that there was no statistically difference of the morphology and size of lesions for 6095W/cm 2 ×8s exposure under the aforementioned different ambient hydrostatic pressures. But the lesions generated at 9752W/cm 2 ×5s exposure under P stat =atmospheric pressure, 0.5MPa, 1.0MPa (all of them are less than p d - ), were larger than those under 1.5MPa, 2.0MPa, 2.5MPa and 3.0MPa (all of them are over than p d - ) which were consistence with 6095W/cm 2 ×8s group. It was concluded that when P stat >p d - , the acoustic cavitation was suppressed and prompted that there was no need to elevate P stat higher than p - to suppress the acoustic cavitation in tissue, just need P stat higher than p d - . Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Hybrid Physical-Chemical Vapor Deposition of Bi2Se3 Thin films on Sapphire

    NASA Astrophysics Data System (ADS)

    Brom, Joseph; Ke, Yue; Du, Renzhong; Gagnon, Jarod; Li, Qi; Redwing, Joan

    2012-02-01

    High quality thin films of topological insulators continue to garner much interest. We report on the growth of highly-oriented thin films of Bi2Se3 on c-plane sapphire using hybrid physical-chemical vapor deposition (HPCVD). The HPCVD process utilizes the thermal decomposition of trimethyl bismuth (TMBi) and evaporation of elemental selenium in a hydrogen ambient to deposit Bi2Se3. Growth parameters including TMBi flow rate and decomposition temperature and selenium evaporation temperature were optimized, effectively changing the Bi:Se ratio, to produce high quality films. Glancing angle x- ray diffraction measurements revealed that the films were c-axis oriented on sapphire. Trigonal crystal planes were observed in atomic force microscopy images with an RMS surface roughness of 1.24 nm over an area of 2μmx2μm. Variable temperature Hall effect measurements were also carried out on films that were nominally 50-70 nm thick. Over the temperature range from 300K down to 4.2K, the carrier concentration remained constant at approximately 6x10^18 cm-3 while the mobility increased from 480 cm^2/Vs to 900 cm^2/Vs. These results demonstrate that the HPCVD technique can be used to deposit Bi2Se3 films with structural and electrical properties comparable to films produced by molecular beam epitaxy.

  4. Effect of polymer residues on the electrical properties of large-area graphene–hexagonal boron nitride planar heterostructures

    DOE PAGES

    Voyloy, Dimitry; Lassiter, Matthew G.; Sokolov, Alexei P.; ...

    2017-06-19

    Polymer residue plays an important role in the performance of 2D heterostructured materials. Herein, we study the effect of polymer residual impurities on the electrical properties of graphene–boron nitride planar heterostructures. Large-area graphene (Gr) and hexagonal boron nitride (h-BN) monolayers were synthesized using chemical vapor deposition techniques. Atomic van-der-Waals heterostructure layers based on varied configurations of Gr and h-BN layers were assembled. The average interlayer resistance of the heterojunctions over a 1 cm 2 area for several planar heterostructure configurations was assessed by impedance spectroscopy and modeled by equivalent electrical circuits. As a result, conductive AFM measurements showed that themore » presence of polymer residues on the surface of the Gr and h-BN monolayers resulted in significant resistance deviations over nanoscale regions.« less

  5. Effect of polymer residues on the electrical properties of large-area graphene–hexagonal boron nitride planar heterostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voyloy, Dimitry; Lassiter, Matthew G.; Sokolov, Alexei P.

    Polymer residue plays an important role in the performance of 2D heterostructured materials. Herein, we study the effect of polymer residual impurities on the electrical properties of graphene–boron nitride planar heterostructures. Large-area graphene (Gr) and hexagonal boron nitride (h-BN) monolayers were synthesized using chemical vapor deposition techniques. Atomic van-der-Waals heterostructure layers based on varied configurations of Gr and h-BN layers were assembled. The average interlayer resistance of the heterojunctions over a 1 cm 2 area for several planar heterostructure configurations was assessed by impedance spectroscopy and modeled by equivalent electrical circuits. As a result, conductive AFM measurements showed that themore » presence of polymer residues on the surface of the Gr and h-BN monolayers resulted in significant resistance deviations over nanoscale regions.« less

  6. Hierarchical TiN nanoparticles-assembled nanopillars for flexible supercapacitors with high volumetric capacitance.

    PubMed

    Qin, Ping; Li, Xingxing; Gao, Biao; Fu, Jijiang; Xia, Lu; Zhang, Xuming; Huo, Kaifu; Shen, Wenli; Chu, Paul K

    2018-05-10

    Titanium nitride (TiN) is an attractive electrode material in fast charging/discharging supercapacitors because of its excellent conductivity. However, the low capacitance and mechanical brittleness of TiN restricts its further application in flexible supercapacitors with high energy density. Thus, it is still a challenge to rationally design TiN electrodes with both high electrochemical and mechanical properties. Herein, the hierarchical TiN nanoparticles-assembled nanopillars (H-TiN NPs) array as binder free electrodes were obtained by nitriding of hierarchical titanium dioxide (TiO2) nanopillars, which was produced by a simple hydrothermal treatment of anodic TiO2 nanotubes (NTs) array in water. The porous TiN nanoparticles connected to each other to form ordered nanopillar arrays, effectively providing larger specific surface area and more active sites for charge storage. The H-TiN NPs delivered a high volumetric capacitance of 120 F cm-3 at 0.83 A cm-3, which is better than that of TiN NTs arrays (69 F cm-3 at 0.83 A cm-3). After assembling into all-solid-state devices, the H-TiN NPs based supercapacitors exhibited outstanding volumetric capacitance of 5.9 F cm-3 at 0.02 A cm-3 and a high energy density of 0.53 mW h cm-3. Our results reveal a new strategy to optimize the supercapacitive performance of metal nitrides.

  7. Retrospective single center study of the efficacy of large spot 532 nm laser for the treatment of facial capillary malformations in 44 patients with the use of three-dimensional image analysis.

    PubMed

    Kwiek, Bartłomiej; Rożalski, Michał; Kowalewski, Cezary; Ambroziak, Marcin

    2017-10-01

    We wanted to asses the efficacy of large spot 532 nm laser for the treatment of facial capillary malformations with the use of three-dimensional (3D) image analysis. Retrospective single center study on previously non-treated patients with facial capillary malformations (CM) was performed. A total of 44 consecutive Caucasian patients aged 5-66 were included. Patients had 3D photography performed before and after and had at least one single session of treatment with 532 nm neodymium-doped yttrium aluminum garnet (Nd:YAG) laser with contact cooling, fluencies ranging from 8 to 11.5 J/cm 2 , pulse duration ranging from 5 to 9 milliseconds and spot size ranging from 5 to 10 mm. Objective analysis of percentage improvement based on 3D digital assessment of combined color and area improvement (global clearance effect [GCE]) were performed. Median maximal improvement achieved during the treatment (GCE max ) was 70.4%. Mean number of laser procedures required to achieve this improvement was 7.1 (ranging from 2 to 14)). Improvement of minimum 25% (GCE 25) was achieved by all patients, of minimum 50% (GCE 50) by 77.3%, of minimum 75% (GCE 75) by 38.6%, and of minimum 90% (GCE 90) by 13.64. Large spot 532 nm laser is highly effective in the treatment of facial CM. 3D color and area image analysis provides an objective method to compare different methods of facial CM treatment in future studies. Lasers Surg. Med. 49:743-749, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. Clinical application of dual photon absorptiometry (DPA) at the lumbar spine (LS) in the diagnosis of osteoporosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahner, H.W.; Dunn, W.L.; Riggs, B.L.

    This study evaluates the effectiveness of DPA to separate patients with osteoporosis (greater than 2 spinal fractures, normal Ca, P, absence of drugs, and metabolic bone disease) from a normal population. Performance criteria for the instrument have been described previously. Data was obtained from a prospective study of 105 normal women, 75 patients with osteoporosis and a retrospective study of 300 patients with osteoporosis seen in 1982/83. The results were as follows: (1) Area density (gm/cm/sup 2/) was found superior to mass (gm) due to the occasional problem to clearly identify the boundaries of L1-4. (2) Separation of the twomore » populations was best when L1-L4,L2-L4, L3 alone or 10 paths over the mid lumbar area were used. One pass was not acceptable. (3) Compression fractures (CF) in the LS showed an increase in area density initially but area density may be undistinguishable from intact vertebrae later. To correct for this loss of bone area a factor predicting the area of lumbar vertebrae and based on patients actual height and weight was introduced and tested. (4) In the retrospective study a negative correlation was found between number of thoracic spine CF and bone mineral values in the LS. (5) A fracture threshold value of BM defined as the level below which 95% of all patients with CF were found was determined to be 0.98 g/cm2. Sixty-five percent of patients with two or more spinal CF could be separated from the normal population (outside 2SD). By using a correction factor for height loss this could be further increased to about 70%. CF in the LS may falsely elevate bone mineral values.« less

  9. Effects of branch height on leaf gas exchange, branch hydraulic conductance and branch sap flux in open-grown ponderosa pine.

    PubMed

    Hubbard, Robert M; Bond, Barbara J; Senock, Randy S; Ryan, Michael G

    2002-06-01

    Recent studies have shown that stomata respond to changes in hydraulic conductance of the flow path from soil to leaf. In open-grown tall trees, branches of different heights may have different hydraulic conductances because of differences in path length and growth. We determined if leaf gas exchange, branch sap flux, leaf specific hydraulic conductance, foliar carbon isotope composition (delta13C) and ratios of leaf area to sapwood area within branches were dependent on branch height (10 and 25 m) within the crowns of four open-grown ponderosa pine (Pinus ponderosa Laws.) trees. We found no difference in leaf gas exchange or leaf specific hydraulic conductance from soil to leaf between the upper and lower canopy of our study trees. Branch sap flux per unit leaf area and per unit sapwood area did not differ between the 10- and 25-m canopy positions; however, branch sap flux per unit sapwood area at the 25-m position had consistently lower values. Branches at the 25-m canopy position had lower leaf to sapwood area ratios (0.17 m2 cm-2) compared with branches at the 10-m position (0.27 m2 cm-2) (P = 0.03). Leaf specific conductance of branches in the upper crown did not differ from that in the lower crown. Other studies at our site indicate lower hydraulic conductance, sap flux, whole-tree canopy conductance and photosynthesis in old trees compared with young trees. This study suggests that height alone may not explain these differences.

  10. A Pt/TiO(2)/Ti Schottky-type selection diode for alleviating the sneak current in resistance switching memory arrays.

    PubMed

    Park, Woo Young; Kim, Gun Hwan; Seok, Jun Yeong; Kim, Kyung Min; Song, Seul Ji; Lee, Min Hwan; Hwang, Cheol Seong

    2010-05-14

    This study examined the properties of Schottky-type diodes composed of Pt/TiO(2)/Ti, where the Pt/TiO(2) and TiO(2)/Ti junctions correspond to the blocking and ohmic contacts, respectively, as the selection device for a resistive switching cross-bar array. An extremely high forward-to-reverse current ratio of approximately 10(9) was achieved at 1 V when the TiO(2) film thickness was 19 nm. TiO(2) film was grown by atomic layer deposition at a substrate temperature of 250 degrees C. Conductive atomic force microscopy revealed that the forward current flew locally, which limits the maximum forward current density to < 10 A cm(-2) for a large electrode (an area of approximately 60 000 microm(2)). However, the local current measurement showed a local forward current density as high as approximately 10(5) A cm(-2). Therefore, it is expected that this type of Schottky diode effectively suppresses the sneak current without adverse interference effects in a nano-scale resistive switching cross-bar array with high block density.

  11. Efficacy of low-level laser therapy on hair regrowth in dogs with noninflammatory alopecia: a pilot study.

    PubMed

    Olivieri, Lara; Cavina, Damiano; Radicchi, Giada; Miragliotta, Vincenzo; Abramo, Francesca

    2015-02-01

    Canine noninflammatory alopecia (CNA) is a heterogeneous group of skin diseases with different underlying pathogenesis. The therapeutic approach is challenging, and new options for treatment are desirable. To test the clinical efficacy of low-level laser therapy (LLLT) on hair regrowth in CNA. Seven dogs of different ages, breeds and genders with a clinical and histopathological diagnosis of noninflammatory alopecia. Each dog was treated twice weekly for a maximum of 2 months with a therapeutic laser producing the following three different wavelengths emerging simultaneously from 21 foci: 13 × 16 mW, 470 nm; 4 × 50 mW, 685 nm; and 4 × 200 mW, 830 nm. The fluence given was 3 J/cm(2) , frequency 5 Hz, amplitude of the irradiated area was 25 cm(2) and application time was 1.34 min. A predetermined alopecic area was left untreated and served as a control area. From one dog, post-treatment biopsies of treated and untreated sites were obtained for histological evaluation of hair density and the percentage of haired and nonhaired follicles. At the end of the study, coat regrowth was greatly improved in six of seven animals and improved in one of seven. By morphometry, the area occupied by hair follicles was 18% in the treated sample and 11% in the untreated one (11%); haired follicles were (per area) 93% in the treated sample and only 9% in the control sample. Our clinical and histological data document promising effects of LLLT on hair regrowth in CNA. Further studies investigating the biological mechanism underlying the effect of LLLT on hair follicle cycling are warranted. © 2014 ESVD and ACVD.

  12. Effect of Vascular Access Site Choice on Radiation Exposure During Coronary Angiography: The REVERE Trial (Randomized Evaluation of Vascular Entry Site and Radiation Exposure).

    PubMed

    Pancholy, Samir B; Joshi, Pankaj; Shah, Sanjay; Rao, Sunil V; Bertrand, Olivier F; Patel, Tejas M

    2015-08-17

    This study sought to perform a randomized noninferiority trial of radiation exposure during cardiac catheterization comparing femoral access (FA) with left radial access (LRA) and right radial access (RRA). Increased radiation exposure with radial approach compared with femoral approach remains a controversial issue. This study randomized 1,493 patients undergoing cardiac catheterization at a tertiary care center to FA, LRA, and RRA in a 1:1:1 fashion. The primary endpoint was air kerma. The secondary endpoints included dose-area product, fluoroscopy time and operator dose per procedure, number of cineangiograms, and number of catheters. Baseline and procedural characteristics were similar among groups. No significant differences were observed in air kerma (medians: FA: 421 mGy [interquartile range (IQR): 337 to 574 mGy], LRA: 454 mGy [IQR: 331 to 643 mGy], and RRA: 483 mGy [IQR: 382 to 592 mGy], p = 0.146), dose-area product (medians: FA: 25.5 Gy cm(2) [IQR: 19.6 to 34.5 Gy cm(2)], LRA: 26.6 Gy cm(2) [IQR: 19.5 to 37.5 Gy cm(2)], and RRA: 27.7 Gy cm(2) [IQR: 21.9 to 34.4 Gy cm(2)], p = 0.40), or fluoroscopy time (medians: FA: 1.3 min [IQR: 1.0 to 1.7 min], LRA: 1.3 min [IQR: 1.0 to 1.7 min], and RRA: 1.32 min [IQR: 1.0 to 1.7 min], p = 0.19) among the 3 access sites. Median operator exposure was higher in the LRA group (3 mrem [IQR: 2 to 5 mrem], p = 0.001 vs. FA, and p = 0.0001 vs. RRA) compared with the FA (2 mrem [IQR: 2 to 4 mrem] and RRA groups (3 mrem [IQR: 2 to 5 mrem]). Radiation exposure to patients was similar during diagnostic coronary angiography with FA, RRA, and LRA. However, LRA was associated with significantly higher operator radiation exposure than were FA and RRA procedures. (Randomized Evaluation of Vascular Entry Site and Radiation Exposure [REVERE]; NCT01677481). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Three-dimensional anode engineering for the direct methanol fuel cell

    NASA Astrophysics Data System (ADS)

    Bauer, A.; Oloman, C. W.; Gyenge, E. L.

    Catalyzed graphite felt three-dimensional anodes were investigated in direct methanol fuel cells (DMFCs) operated with sulfuric acid supporting electrolyte. With a conventional serpentine channel flow field the preferred anode thickness was 100 μm, while a novel flow-by anode showed the best performance with a thickness of 200-300 μm. The effects of altering the methanol concentration, anolyte flow rate and operating temperature on the fuel cell superficial power density were studied by full (2 3 + 1) factorial experiments on a cell with anode area of 5 cm 2 and excess oxidant O 2 at 200 kPa(abs). For operation in the flow-by mode with 2 M methanol at 2 cm 3 min -1 and 353 K the peak power density was 2380 W m -2 with a PtRuMo anode catalyst, while a PtRu catalyst yielded 2240 W m -2 under the same conditions.

  14. Effects of pretreatment on the surface chemistry and pore size properties of nitrogen functionalized and alkylated granular activated carbon

    NASA Astrophysics Data System (ADS)

    Chen, Jiajun; Zhai, Yunbo; Chen, Hongmei; Li, Caiting; Zeng, Guangming; Pang, Daoxiong; Lu, Pei

    2012-12-01

    In this paper, granular activated carbon (GAC) from coconut shell was pretreated by HNO3, H2O2 and urea-formaldehyde resin, respectively. Then the obtained materials were functionalized in the same way for nitrogen group, and then alkylated. Effects of pretreatment on the surface chemistry and pore size of modified GACs were studied. Surface area and micropore volume of modified GAC which pretreated by HNO3 were 723.88 m2/g and 0.229 cm3/g, respectively, while virgin GAC were 742.34 m2/g and 0.276 cm3/g. Surface area and micropore volume decrease of the modified GACs which pretreated by the others two methods were more drastically. The types of groups presented were analyzed by electrophoresis, Fourier transform infrared spectroscopy (FTIR), and X-ray photoelectron spectroscopy (XPS). Nsbnd CH3 group and Cdbnd N group were detected on the surfaces of these three kinds of modified GACs. Results of XPS showed that the nitrogen functions of modified GAC which pretreated by H2O2 was 4.07%, it was more than that of the others two pretreatment methods. However, the modified GAC which pretreated by urea-formaldehyde resin was fixed more pyridine structure, which structure percentage was 45.88%, in addition, there were more basic groups or charge on the surface than the others.

  15. Role of Beam Spot Size in Heating Targets at Depth.

    PubMed

    Ross, E Victor; Childs, James

    2015-12-01

    Wavelength, fluence and pulse width are primary device parameters for the treatment of skin and hair conditions. Wavelength selection is based on tissue scatter and target chromophores. Pulse width is chosen to optimize target heating. Energy absorbed by a target is determined by fluence and spot size of the light source as well as the depth of the target. We conducted an in vitro skin study and simulations to compare heating of a target at a particular depth versus spot size. Porcine skin and fat tissue were prepared and separated to form a 2mm skin layer above a 1 cm thick fat layer. A 50 μm thermocouple was placed between the layers and centered beneath a 23 x 38 mm treatment window of an 805 nm diode laser device (Vectus, Cynosure, Westford, MA). Apertures provided various incident beam spot sizes and the temperature rise of the thermocouple was measured for a fixed fluence. The 2mm deep target's temperature rise versus treatment area showed two regimes with different positive slopes. The first regime up to approximately 1 cm(2) area has a greater temperature rise versus area than that for the regime greater than 1 cm(2). The slope in the second regime is nonetheless appreciable and provides a fluence reduction factor for skin safety. The same temperature rise in a target at 2 mm depth (typical hair bulb depth in some areas) is realized by increasing the area from 1 to 4 cm(2) while reducing the fluence by half. The role of spot size and in situ beam divergence is an important consideration to determine optimum fluence settings that increase skin safety when treating deeper targets.

  16. Percutaneous transluminal balloon dilatation of the mitral valve in pregnancy.

    PubMed

    Smith, R; Brender, D; McCredie, M

    1989-06-01

    Pregnancy can cause life threatening complications in women with mitral stenosis, and there is a substantial risk of fetal death if valvotomy under cardiopulmonary bypass is required. A patient is described in whom pulmonary oedema developed after delivery of her first child by caesarean section 13 months previously. Subsequent cardiac catheterisation showed severe mitral stenosis (valve area 0.96 cm2, valve gradient 12 mm Hg, pulmonary artery pressure 30/16 mm Hg). Before valvotomy could be performed the patient again became pregnant and presented in pulmonary oedema at twenty two weeks' gestation. Medical treatment was unsuccessful and she underwent percutaneous transluminal balloon dilatation of the mitral valve. This increased the valve area to 1.78 cm2 and reduced the transmitral gradient to 6 mm Hg. The procedure was uncomplicated, and she remained symptom free on no medication. She delivered vaginally at 37 weeks' gestation. Percutaneous transluminal balloon dilatation of the mitral valve is a safe and effective alternative to mitral valvotomy in pregnancy.

  17. Distance from the growth plate and Its relation to the outcome of unicameral bone cyst treatment.

    PubMed

    Haidar, Saadallah George; Culliford, David J; Gent, Edward David; Clarke, Nicholas M P

    2011-04-01

    Interventions to treat unicameral bone cysts vary. Nonetheless, regardless of the intervention modality, the outcome is not certain. The purpose of this study was to determine if the distance between the growth plate and the cyst can be used to predict the outcome of the treatment. Retrospectively, we assessed the outcome of 39 interventions in nineteen children that were performed between 1994 and 2003. Seventeen different modalities of treatment were employed. There were three female and sixteen male patients. The average age was 8 years. Nine cysts were in the greater trochanter area, three were in the femoral capital area and seven were in the proximal humerus. According to the cyst's distance from the growth plate, at the intervention time, there were 18 cases within less than 2 cm and 21 cases of more than 2 cm. Complete healing was achieved in 10 children (employing seven different modalities). In nine of them, the cysts were more than 2 cm away from the growth plate. In one child, the cyst was within less than 2 cm of the growth plate, however, treatment here involved epiphyseodesis. This study confirmed that, regardless of intervention modality, complete healing was not achievable in those cysts that are within less than 2 cm of an active growth plate. Complete healing was possible in those cysts that are more than 2 cm away from the growth plate. The 2-cm distance from the growth plate could be used as a predictor of treatment outcome of unicameral bone cysts.

  18. Historical trend in heavy metal pollution in core sediments from the Masan Bay, Korea.

    PubMed

    Cho, Jinhyung; Hyun, Sangmin; Han, J-H; Kim, Suhyun; Shin, Dong-Hyeok

    2015-06-15

    The spatiotemporal distribution and their mass accumulation rate (MAR) of heavy metals were investigated to evaluate the time-dependent historical trends of heavy metal concentration. The three short cores used for this study were collected from the catchment area (MS-PC5, 60cm length), the central part (MS-PC4, 40cm length) and the offshore (MS-PC2, 60cm length) of the Masan Bay, Korea. The concentration of heavy metals (Co, Ni, Cu, Zn, Cr and Pb) in catchment area is as much as 1.5-2 times higher than central part of the Bay, and about 2 times higher than offshore area approximately. In particular, MAR of metals (Cu, Zn and Pb) show clear spatiotemporal variation, so that MAR's of heavy metal may provide more accurate information in evaluating the degree of pollution. Temporally, the heavy metal concentration had been increased since the late 1970s, but it seems to decrease again since the 2004yr in catchment area. This may came from concentrated efforts for the government to reduce industrial waste release. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women

    PubMed Central

    Alijahan, Rahele; Kordi, Masoumeh; Poorjavad, Munira; Ebrahimzadeh, Saeed

    2014-01-01

    Background: Dystocia is one of the important causes of maternal morbidity and mortality in low-income countries. This study was aimed to determine the diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women. Materials and Methods: This prospective cohort study was conducted on 447 nulliparous women who referred to Omolbanin hospital. Several maternal anthropometric measurements such as height, transverse and vertical diameters of Michaelis sacral rhomboid area, foot length, head circumference, vertebral and lower limb length, symphysio-fundal height, and abdominal girth were taken in cervical dilatation ≤ 5 cm. Labor progression was controlled by a researcher blind to these measurements. After delivery, the accuracy of individual and combined measurements in prediction of dystocia was analyzed. Dystocia was defined as cesarean section and vacuum or forceps delivery for abnormal progress of labor (cervical dilatation less than 1 cm/h in the active phase for 2 h, and during the second stage, beyond 2 h or fetal head descend less than 1 cm/h). Results: Among the different anthropometric measurements, transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm, maternal height ≤ 155 cm, height to symphysio-fundal height ratio ≤4.7, lower limb length ≤78 cm, and head circumference to height ratio ≥ 35.05 with accuracy of 81.2%, 68.2%, 65.5%, 63.3%, and 61.5%, respectively, were better predictors. The best predictor was obtained by combination of maternal height ≤155 cm or the transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm and Johnson's formula estimated fetal weight ≥3255 g, with an accuracy of 90.5%, sensitivity of 70%, and specificity of 93.7%. Conclusions: Combination of other anthropometric measurements and estimated fetal weight with maternal height in comparison to maternal height alone leads to a better predictor for dystocia. PMID:24554954

  20. Diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women.

    PubMed

    Alijahan, Rahele; Kordi, Masoumeh; Poorjavad, Munira; Ebrahimzadeh, Saeed

    2014-01-01

    Dystocia is one of the important causes of maternal morbidity and mortality in low-income countries. This study was aimed to determine the diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women. This prospective cohort study was conducted on 447 nulliparous women who referred to Omolbanin hospital. Several maternal anthropometric measurements such as height, transverse and vertical diameters of Michaelis sacral rhomboid area, foot length, head circumference, vertebral and lower limb length, symphysio-fundal height, and abdominal girth were taken in cervical dilatation ≤ 5 cm. Labor progression was controlled by a researcher blind to these measurements. After delivery, the accuracy of individual and combined measurements in prediction of dystocia was analyzed. Dystocia was defined as cesarean section and vacuum or forceps delivery for abnormal progress of labor (cervical dilatation less than 1 cm/h in the active phase for 2 h, and during the second stage, beyond 2 h or fetal head descend less than 1 cm/h). Among the different anthropometric measurements, transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm, maternal height ≤ 155 cm, height to symphysio-fundal height ratio ≤4.7, lower limb length ≤78 cm, and head circumference to height ratio ≥ 35.05 with accuracy of 81.2%, 68.2%, 65.5%, 63.3%, and 61.5%, respectively, were better predictors. The best predictor was obtained by combination of maternal height ≤155 cm or the transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm and Johnson's formula estimated fetal weight ≥3255 g, with an accuracy of 90.5%, sensitivity of 70%, and specificity of 93.7%. Combination of other anthropometric measurements and estimated fetal weight with maternal height in comparison to maternal height alone leads to a better predictor for dystocia.

  1. Impact of Room Location on UV-C Irradiance and UV-C Dosage and Antimicrobial Effect Delivered by a Mobile UV-C Light Device.

    PubMed

    Boyce, John M; Farrel, Patricia A; Towle, Dana; Fekieta, Renee; Aniskiewicz, Michael

    2016-06-01

    OBJECTIVE To evaluate ultraviolet C (UV-C) irradiance, UV-C dosage, and antimicrobial effect achieved by a mobile continuous UV-C device. DESIGN Prospective observational study. METHODS We used 6 UV light sensors to determine UV-C irradiance (W/cm2) and UV-C dosage (µWsec/cm2) at various distances from and orientations relative to the UV-C device during 5-minute and 15-minute cycles in an ICU room and a surgical ward room. In both rooms, stainless-steel disks inoculated with methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), and Clostridium difficile spores were placed next to sensors, and UV-C dosages and log10 reductions of target organisms achieved during 5-minute and 15-minute cycles were determined. Mean irradiance and dosage readings were compared using ANOVA. RESULTS Mean UV-C irradiance was nearly 1.0E-03 W/cm2 in direct sight at a distance of 1.3 m (4 ft) from the device but was 1.12E-05 W/cm2 on a horizontal surface in a shaded area 3.3 m (10 ft) from the device (P4 to 1-3 for MRSA, >4 to 1-2 for VRE and >4 to 0 log10 for C. difficile spores, depending on the distance from, and orientation relative to, the device with 5-minute and 15-minute cycles. CONCLUSION UV-C irradiance, dosage, and antimicrobial effect received from a mobile UV-C device varied substantially based on location in a room relative to the UV-C device. Infect Control Hosp Epidemiol 2016;37:667-672.

  2. Suture technique does not affect hemodynamic performance of the small supra-annular Trifecta bioprosthesis.

    PubMed

    Ugur, Murat; Byrne, John G; Bavaria, Joseph E; Cheung, Anson; Petracek, Michael; Groh, Mark A; Suri, Rakesh M; Borger, Michael A; Schaff, Hartzell V

    2014-10-01

    The study objective was to evaluate whether aortic valve replacement with the Trifecta valve (St Jude Medical Inc, St Paul, Minn) using simple sutures produces better hemodynamic performance than valve replacement with noneverting pledget-reinforced sutures. We analyzed prospectively acquired 1-year hemodynamic data of patients with small aortic annulus sizes who were enrolled in a multicenter trial of the Trifecta aortic valve bioprosthesis and underwent aortic valve replacement with a 19-mm or 21-mm bioprosthesis between August 2007 and November 2009. We compared preoperative clinical information and 1-year postoperative hemodynamic data for noneverting pledget-reinforced sutures (group 1) versus everting mattress sutures or simple sutures (group 2). A total of 346 patients underwent aortic valve replacement: 269 in group 1 and 77 in group 2. Preoperative demographic characteristics for the 2 groups were similar. For groups 1 and 2, the mean gradient was 10.4±4.7 mm Hg and 11.1±4.4 mm Hg for 19-mm valves, respectively, and 8.4±3.5 mm Hg and 8.8±3.6 mm Hg for 21-mm valves, respectively; the effective orifice area was 1.40 cm2 and 1.25 cm2 for 19-mm valves, respectively, and 1.57 cm2 and 1.50 cm2 for 21-mm valves, respectively. The rate of severe prosthesis-patient mismatch (indexed effective orifice area≤0.65 cm2/m2) was 18.6% (n=11) and 25% (n=6) for 19-mm valves, respectively, and 10.9% (n=20) and 16.3% (n=8) for 21-mm valves, respectively. The suture method did not affect hemodynamic performance of supra-annular bioprostheses in patients with small aortic annulus sizes. Choice of suture technique should be determined by surgeon experience and local anatomic features. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  3. [Effects of tillage practices on root spatial distribution and yield of spring wheat and pea in the dry land farming areas of central Gansu, China].

    PubMed

    Zhang, Ming Jun; Li, Ling Ling; Xie, Jun Hong; Peng, Zheng Kai; Ren, Jin Hu

    2017-12-01

    A field experiment was conducted to explore the mechanism of cultivation measures in affecting crop yield by investigating root distribution in spring wheat-pea rotation based on a long-term conservation tillage practices in a farming region of Gansu. The results showed that with the develo-pment of growth period, the total root length, root surface area of spring wheat and pea showed a consistent trend of increase after initial decrease and reached the maximum at flowering stage. Higher root distribution was found in the 0-10 cm soil layer at seedling and 10-30 cm soil layer at flowering and maturity stages in spring wheat, while in the field pea, higher root distribution was found in the 0-10 cm soil layer at seedling and maturity, and in the 10-30 cm soil layer at flowering stages. No tillage with straw mulching and plastic mulching increased the root length and root surface area. Compared with conventional tillage in spring wheat and field pea, root length increased by 35.9% to 92.6%, and root surface area increased by 43.2% to 162.4%, respectively. No tillage with straw mulching and plastic mulching optimized spring wheat and pea root system distribution, compared with conventional tillage, increased spring wheat and field pea root length and root surface area ratio at 0-10 cm depths at the seedling stage, the root distribution at deeper depths increased significantly at flowering and maturity stages, and no tillage with straw mulching increased root length and root surface area ratio by 3.3% and 9.7% respectively, in 30-80 cm soil layer at the flowering stage. The total root length, root surface area and yield had significantly positive correlation for spring wheat in each growth period, and the total root length and pea yield also had significant positive correlation. No tillage with straw mulching and plastic mulching boosted yield of spring wheat and pea by 23.4%-38.7% compared with the conventional tillage, and the water use efficiency was increased by 13.7%-28.5%. It was concluded that no-till farming and straw mulching (plastic) could increase crop root length and root surface area, optimize the spatial distribution of roots in the soil, enhance crop root layer absorption ability, so as to improve crop yield and water utilization.

  4. [Spatial heterogeneity of soil moisture of mountain apple orchards with rainwater collection and infiltration (RWCI) system in the Loess Plateau, China].

    PubMed

    Song, Xiao Lin; Zhao, Xi Ning; Gao, Xiao Dong; Wu, Pu Te; Ma, Wen; Yao, Jie; Jiang, Xiao Li; Zhang, Wei

    2017-11-01

    Water scarcity is a critical factor influencing rain-fed agricultural production on the Loess Plateau, and the exploitation of rainwater is an effective avenue to alleviate water scarcity in this area. This study was conducted to investigate the spatial and temporal distribution of soil moisture in the 0-300 cm under a 21-year-old apple orchard with the rainwater collection and infiltration (RWCI) system by using a time domain reflectometer (TDR) probe on the Loess Plateau. The results showed that there was a low soil moisture zone in the 40-80 cm under the CK, and the RWCI system significantly increased soil moisture in this depth interval. Over this depth, the annual average soil moisture under RWCI 40 , RWCI 60 and RWCI 80 was 39.2%, 47.2% and 29.1% higher than that of bare slope (BS) and 75.3%, 85.4% and 62.7% higher than that of CK, respectively. The maximum infiltration depth of water under RWCI 40 , RWCI 60 and RWCI 80 was 80 cm, 120 cm and 180 cm, respectively, and the soil moisture in the 0-60, 0-100 and 0-120 cm was more affected by RWCI 40 , RWCI 60 and RWCI 80 , respectively. Over the whole growth period of apple tree, the maximum value of soil moisture content in the 0-300 cm existed in the RWCI 80 treatment, followed by the RWCI 40 and RWCI 60 treatments. Overall, the RWCI system is an effective meaning of transforming rainwater to available water resources and realizing efficient use of agricultural water on the Loess Plateau.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitaker, Thomas J., E-mail: whitaker.thomas@mayo.edu; Beltran, Chris; Tryggestad, Erik

    Purpose: Delayed charge is a small amount of charge that is delivered to the patient after the planned irradiation is halted, which may degrade the quality of the treatment by delivering unwarranted dose to the patient. This study compares two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam. Methods: The delivery of several treatment plans was simulated by applying a normally distributed value of delayed charge, with a mean of 0.001(SD 0.00025) MU, to each spot. Two correction methods were used to account for the delayed charge.more » Method one (CM1), which is in active clinical use, accounts for the delayed charge by adjusting the MU of the current spot based on the cumulative MU. Method two (CM2) in addition reduces the planned MU by a predicted value. Every fraction of a treatment was simulated using each method and then recomputed in the treatment planning system. The dose difference between the original plan and the sum of the simulated fractions was evaluated. Both methods were tested in a water phantom with a single beam and simple target geometry. Two separate phantom tests were performed. In one test the dose per fraction was varied from 0.5 to 2 Gy using 25 fractions per plan. In the other test the number fractions were varied from 1 to 25, using 2 Gy per fraction. Three patient plans were used to determine the effect of delayed charge on the delivered dose under realistic clinical conditions. The order of spot delivery using CM1 was investigated by randomly selecting the starting spot for each layer, and by alternating per layer the starting spot from first to last. Only discrete spot scanning was considered in this study. Results: Using the phantom setup and varying the dose per fraction, the maximum dose difference for each plan of 25 fractions was 0.37–0.39 Gy and 0.03–0.05 Gy for CM1 and CM2, respectively. While varying the total number of fractions, the maximum dose difference increased at a rate of 0.015 Gy and 0.0018 Gy per fraction for CM1 and CM2, respectively. For CM1, the largest dose difference was found at the location of the first spot in each energy layer, whereas for CM2 the difference in dose was small and showed no dependence on location. For CM1, all of the fields in the patient plans had an area where their excess dose overlapped. No such correlation was found when using CM2. Randomly selecting the starting spot reduces the maximum dose difference from 0.708 to 0.15 Gy. Alternating between first and last spot reduces the maximum dose difference from 0.708 to 0.37 Gy. In the patient plans the excess dose scaled linearly at 0.014 Gy per field per fraction for CM1 and standard delivery order. Conclusions: The predictive model CM2 is superior to a cumulative irradiation model CM1 for minimizing the effects of delayed charge, particularly when considering maximal dose discrepancies and the potential for unplanned hot-spots. This study shows that the dose discrepancy potentially scales at 0.014 Gy per field per fraction for CM1.« less

  6. Effects of different fluences of low-level laser therapy in an experimental model of spinal cord injury in rats.

    PubMed

    Veronez, Suellen; Assis, Lívia; Del Campo, Paula; de Oliveira, Flávia; de Castro, Gláucia; Renno, Ana Claudia Muniz; Medalha, Carla Christina

    2017-02-01

    The aim of this study was to evaluate the in vivo response of different fluences of low-level laser therapy (LLLT) on the area of the injury, inflammatory markers, and functional recovery using an experimental model of traumatic spinal cord injury (SCI). Thirty two rats were randomly divided into four experimental groups: control group (CG), laser-treated group 500 J/cm 2 (L-500), laser-treated group 750 J/cm 2 (L-750), and laser-treated group 1000 J/cm 2 (L-1000). SCI was performed by an impactor equipment (between the ninth and tenth thoracic vertebrae), with a pressure of 150 kdyn. Afterwards, the injured region was irradiated daily for seven consecutive sessions, using an 808-nm laser, at the respective fluence of each experimental groups. Motor function and tactile sensitivity were performed on days 1 and 7 post-surgery. Animals were euthanized on the eighth day after injury, and the samples were retrieved for histological and immunohistochemistry analyses. Functional evaluation and tactile sensitivity were improved after LLLT, at the higher fluence. Additionally, LLLT, at 750 and 1000 J/cm 2 , reduces the lesion volume and modulates the inflammatory process with decrease of CD-68 protein expression. These results suggest that LLLT at higher doses was effective in promoting functional recovery and modulating inflammatory process in the spinal cord of rats after SCI.

  7. A two-step hydrothermal synthesis approach to synthesize NiCo2S4/NiS hollow nanospheres for high-performance asymmetric supercapacitors

    NASA Astrophysics Data System (ADS)

    Xu, Rui; Lin, Jianming; Wu, Jihuai; Huang, Miaoliang; Fan, Leqing; He, Xin; Wang, Yiting; Xu, Zedong

    2017-11-01

    In this work, a high-performance asymmetric supercapacitor device based on NiCo2S4/NiS hollow nanospheres as the positive electrode and the porous activated carbon as the negative electrode was successfully fabricated via a facile two-step hydrothermal synthesis approach. This NiCo2S4/NiS//activated carbon asymmetric supercapacitor achieved a high energy density of 43.7 Wh kg-1 at a power density of 160 W kg-1, an encouraging specific capacitance of 123 F g-1 at a current density of 1 mA cm-2, as well as a long-term performance with capacitance degradation of 5.2% after 3000 consecutive cycles at 1 mA cm-2. Moreover, the NiCo2S4/NiS electrode also demonstrated an excellent specific capacitance (1947.5 F g-1 at 3 mA cm-2) and an outstanding cycling stability (retaining 90.3% after 1000 cycles). The remarkable electrochemical performances may be attributed to the effect of NiS doping on NiCo2S4 which could enlarge the surface area and increase the surface roughness.

  8. Facile preparation of core-shell magnetic metal-organic framework nanospheres for the selective enrichment of endogenous peptides.

    PubMed

    Xiong, Zhichao; Ji, Yongsheng; Fang, Chunli; Zhang, Quanqing; Zhang, Lingyi; Ye, Mingliang; Zhang, Weibing; Zou, Hanfa

    2014-06-10

    Facile preparation of core-shell magnetic metal-organic framework nanospheres by a layer-by-layer approach is presented. The nanospheres have high surface area (285.89 cm(2)  g(-1)), large pore volume (0.18 cm(3)  g(-1)), two kinds of mesopores (2.50 and 4.72 nm), excellent magnetic responsivity (55.65 emu g(-1)), structural stability, and good dispersibility. The combination of porosity, hydrophobicity, and uniform magnetism was exploited for effective enrichment of peptides with simultaneous exclusion of high molecular weight proteins. The nanospheres were successfully applied in the selective enrichment of endogenous peptides in human serum. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Surface Analysis of the Laser Cleaned Metal Threads

    NASA Astrophysics Data System (ADS)

    Sokhan, M.; Hartog, F.; McPhail, D.

    The laser cleaning of the tarnished silver threads was carried out using Nd:YAG laser radiation at IR (1064 nm) and visible wavelengths (532 nm). The preliminary tests were made on the piece of silk with the silver embroidery with the clean and tarnished areas. FIBS and SIMS analysis were used for analysing the condition of the surface before and after laser irradiation. It was found that irradiation below 0.4 J/cm-2 and higher than 1.0 J/cm-2 fluences aggravates the process of tarnishing and leads to the yellowing effect. The results of preliminary tests were used for finding the optimum cleaning regime for the laser cleaning of the real museum artefact: "Women Riding Jacket" dated to the beginning of 18th century.

  10. Long-term effects of bottom trawling on large sponges in the Gulf of Alaska

    NASA Astrophysics Data System (ADS)

    Malecha, Patrick; Heifetz, Jonathan

    2017-11-01

    Manipulative studies that characterize short-term effects of bottom trawls on seafloor habitats are numerous, but studies that examine long-term effects are rare. The long-term (13 years) effects of a single bottom trawl on large (>20 cm) erect sponges were investigated by revisiting the site of prior experimental trawling studies. In prior studies, large sponges were assessed immediately after trawling and 1 yr post-trawling. Thirteen years post-trawling, the average density of large sponges was 31.7% lower (range 1.5-53.0%) and the incidence of sponge damage (torn, necrotic, missing tissue, prone) was 58.8% higher within strip transects in trawled versus untrawled reference areas. For all sponge species combined, the mean density of large sponges was 3.19 individuals 100 m-2 in trawled areas and 4.67 individuals 100 m-2 in reference areas. The most abundant sponge species in both trawled and reference areas was Rhabdocalyptus dawsoni. Mean density of this species differed greatly between trawled (1.57 individuals 100 m-2) and reference areas (2.91 individuals 100 m-2). Thirteen years after trawling, the mean percentage of damaged sponges on strip transects was 15.3% in trawled areas and 6.3% in reference areas. The rate of damage in trawled areas was less than that observed both immediately after trawling and 1 year later. The persistence of damage (lower sponge densities and higher rates of injury in trawled areas) and the potential resultant changes to benthic communities where deepwater habitat-forming biota, such as large erect sponges, are present provide rationale for cautious management of the long term effects of bottom trawling.

  11. First Peek of ASTRO-H Soft X-Ray Telescope (SXT) In-Orbit Performance

    NASA Technical Reports Server (NTRS)

    Okajima, Takashi; Soong, Yang; Serlemitsos, Peter J.; Mori, Hideyuki; Olsen, Lawrence; Robinson, David; Koenecke, Richard; Chang, William; Hahne, David; Iisuka, Ryo; hide

    2016-01-01

    ASTRO-H (Hitomi) is a Japanese X-ray astrophysics satellite just launched in February, 2016, from Tanegashima, Japan by a JAXA's H-IIA launch vehicle. It has two Soft X-ray Telescopes (SXTs), among other instruments, that were developed by the NASA Goddard Space Flight Center in collaboration with ISAS/JAXA and Nagoya University. One is for an X-ray micro-calorimeter instrument (Soft X-ray Spectrometer, SXS) and the other for an X-ray CCD camera (Soft X-ray Imager, SXI), both covering the X-ray energy band up to 15 keV. The two SXTs were fully characterized at the 30-m X-ray beam line at ISAS/JAXA. The combined SXT+SXS system effective area is about 250 and 300 cm(exp 2) at 1 and 6 keV, respectively, although observations were performed with the gate valve at the dewar entrance closed, which blocks most of low energy X-rays and some of high energy ones. The angular resolution for SXS is 1.2 arcmin (Half Power Diameter, HPD). The combined SXT+SXI system effective area is about 370 and 350 cm (exp 2) at 1 and 6 keV, respectively. The angular resolution for SXI is 1.3 arcmin (HPD). The both SXTs have a field of view of about 16 arcmin (FWHM of their vignetting functions).The SXT+SXS field of view is limited to 3 x 3 arcmin by the SXS array size. In-flight data available to the SXT team was limited at the time of this conference and a point-like source data is not available for the SXT+SXS. Although due to lack of attitude information we were unable to reconstruct a point spread function of SXT+SXI, according to RXJ1856.5-3754 data, the SXT seems to be working as expected in terms of imaging capability. As for the overall effective area response for both SXT+SXS and SXT+SXI, consistent spectral model fitting parameters with the previous measurements were obtained for Crab and G21.5-0.9 data. On the other hand, their 2-10 keV fluxes differ by about 20% at this point. Calibration work is still under progress. The SXT is the latest version of the aluminum foil X-ray mirror, which is extremely light-weight and very low cost, yet produces large effective area over a wide energy-band. Its area-mass ratio is the largest, 16 cm(exp 2)/kg, among ASTRO-H, Chandra, and XMM-Newton mirrors. The aluminum foil mirror is a still compelling technology depending on the mission science goal.

  12. Evaluation of laser photobiomodulation on bone defect in the femur of osteoporotic rats: a Raman spectral study

    NASA Astrophysics Data System (ADS)

    Soares, Luiz Guilherme P.; Aciole, Jouber Mateus d. S.; Neves, Bruno Luiz R. C.; Silveira, Landulfo; Pinheiro, Antônio L. B.

    2015-03-01

    Phototherapies have shown positive effects on the bone repair process, increasing the blood supply to the injured area. The aim of this study was to assess through Raman spectroscopy, the efficacy of laser phototherapy (λ = 780 nm, P = 70 mW, CW, 20.4 J/cm2 per session, 163.2 J/cm2 per treatment) on the bone repair process of osteoporotic rats. The osteoporosis induction was achieved by ovariectomy surgery. Thirty Wistar rats were divided into 4 groups (Basal; OVX, OVX + Clot and OVX + Clot + Laser), then subdivided into 2 subgroups according to the experimental time (15 and 30 days). After the osteoporosis induction time (60 days), a bone defect with 2 mm was created with a trephine drill in the right femur in the animals of groups OVX, Clot and Clot + Laser. After surgery, the irradiation protocol was applied in the same groups on repeated sessions every 48 hours during 15 days. The samples were analyzed by Raman Spectroscopy to assess the inorganic content of phosphate and carbonated hydroxyapatite (~960 and 1070 cm-1, respectively) and organic lipids and proteins (~1454 cm-1). Statistical analysis (ANOVA, Student-T test) showed significant difference between groups Basal, OVX + Clot, and OVX + Clot + Laser for the inorganic content peaks at ~960 (p≤0.001), and ~1070 cm-1 (p≤0.001) in both periods of 15 and 30 days, however on peak at ~1450 cm-1 no differences were detected. It was concluded that the Laser phototherapy increased deposition of HA on bone repair process of osteoporotic rats.

  13. Centromedian-parafascicular deep brain stimulation induces differential functional inhibition of the motor, associative, and limbic circuits in large animals.

    PubMed

    Kim, Joo Pyung; Min, Hoon-Ki; Knight, Emily J; Duffy, Penelope S; Abulseoud, Osama A; Marsh, Michael P; Kelsey, Katherine; Blaha, Charles D; Bennet, Kevin E; Frye, Mark A; Lee, Kendall H

    2013-12-15

    Deep brain stimulation (DBS) of the centromedian-parafascicular (CM-Pf) thalamic nuclei has been considered an option for treating Tourette syndrome. Using a large animal DBS model, this study was designed to explore the network effects of CM-Pf DBS. The combination of DBS and functional magnetic resonance imaging is a powerful means of tracing brain circuitry and testing the modulatory effects of electrical stimulation on a neuronal network in vivo. With a within-subjects design, we tested the proportional effects of CM and Pf DBS by manipulating current spread and varying stimulation contacts in healthy pigs (n = 5). Our results suggests that CM-Pf DBS has an inhibitory modulating effect in areas that have been suggested as contributing to impaired sensory-motor and emotional processing. The results also help to define the differential neural circuitry effects of the CM and Pf with evidence of prominent sensorimotor/associative effects for CM DBS and prominent limbic/associative effects for Pf DBS. Our results support the notion that stimulation of deep brain structures, such as the CM-Pf, modulates multiple networks with cortical effects. The networks affected by CM-Pf stimulation in this study reinforce the conceptualization of Tourette syndrome as a condition with psychiatric and motor symptoms and of CM-Pf DBS as a potentially effective tool for treating both types of symptoms. Copyright © 2013 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  14. Relationship between geomorphology and lithotypes of lahar deposit from Chokai volcano, Japan

    NASA Astrophysics Data System (ADS)

    Minami, Y.; Ohba, T.; Hayashi, S.; Kataoka, K.

    2013-12-01

    Chokai volcano, located in the northern Honshu arc in Japan, is an andesitic stratovolcano that collapsed partly at ca. 2500 years ago. A post collapse lahar deposit (Shirayukigawa lahar deposit) is distributed in the northern foot of the volcanic edifice. The deposit consists of 16 units of debris flow, hyperconcentrated flow and streamflow deposits. The Shirayukigawa lahar deposit has a total thickness of 30 m and overlies the 2.5-ka Kisakata debris avalanche deposit. Shirayukigawa lahar deposit forms volcanic fan and volcanic apron. The volcanic fan is subdivided into four areas on the basis of slope angles and of geomorphological features: 1) steeply sloped area, 2) moderately sloped area, 3) gently sloped area and 4) horizontal area. From sedimentary facies and structures, each unit of the Shirayukigawa lahar deposit is classified into one of four lithotypes: clast-supported debris flow deposit (Cc), matrix-supported debris flow deposit (Cm1), hyperconcentrated flow deposit (Cm2) and streamflow deposit (Sl). Each type has the following lithological characteristics. The lithotypes are well correlated with the geomorphology of the volcanic fan. The steeply-sloped and the moderately-sloped areas are dominated by Cc, Cm1, and Cm2, and The horizontal area are dominated by Sl. Debris flow deposit (Cc) is massive, very poorly sorted, partly graded, and clast-supported with polymictic clasts dominated by subrounded to rounded volcanic clasts. Matrix is sandy to muddy. Preferred clast orientation are present. Debris flow deposit (Cm1) is massive, very poorly sorted, and matrix-supported with polymictic clasts dominated by subrounded to rounded volcanic clasts. Matrix is sandy to muddy. Some layers exhibit coarse-tail normal/inverse grading. Most clasts are oriented. Hyperconcentrated flow deposit (Cm2) is massive to diffusely laminated, very poorly sorted and matrix-supported with polymictic clasts dominated by subrounded to rounded volcanic rocks. Matrix is sandy. The clasts are randomly distributed in the sandy matrix except for some clast-concentrated lenticular layers. Clasts smaller than 1cm account for about 10 percent of the deposits. Maximum clast size is about 30 cm. Streamflow deposit (Sl) is weakly parallel/cross-laminated, sorted and partly graded. The deposit contains volcanic clasts smaller than 20cm, which clasts are preferentially oriented and account for about 5% of the deposit. Clasts of the deposits consist of altered andesite, fresh andesite, mudstone and sandstone. The sedimentary clasts were derived from the substrate. The proportion of altered andesite clasts decreases upwards through the units. Matrix components in the lower eight units (C-LHR) are different from those of the upper eight units (S-LHR). In C-LHR units, grayish blue clay is dominant in matrix, whereas in S-LHR units, brownish yellow volcanic sand is dominant in matrix. Hydrothermal clay minerals such as smectite, chlorite, pyrophyllite and kaoline group minerals are rich in C-LHR units, whereas they are poor in S-LHR units. The stratigraphic variation in matrix component reflects temporal variation in supplied materials from source region.

  15. Biofilm growth on polyvinylchloride surface incubated in suboptimal microbial warm water and effect of sanitizers on biofilm removal post biofilm formation.

    PubMed

    Maharjan, Pramir; Huff, Geraldine; Zhang, Wen; Watkins, Susan

    2017-01-01

    An in vitro experiment was conducted to understand the nature of biofilm growth on polyvinyl chloride (PVC) surface when exposed to suboptimal-quality microbial water (>4 log 10 cfu/mL) obtained from a poultry drinking water source mimicking water in waterlines during the first week of poultry brooding condition. PVC sections (internal surface area of 15.16 cm 2 ) were utilized in the study to grow biofilm. After a 7-d test period, test coupons with 7-day-old biofilm were transferred into autoclaved municipal water and then treated with either chlorine-based or hydrogen peroxide-based sanitizer at bird drinking water rate, to see the impact on removal of biofilm formed on test coupons. Two trials (T1 and T2) were conducted. Test coupons used in T1 and T2 had the bacterial growth of 3.67 (SEM 0.04) and 3.97 (SEM 0.11) log 10 cfu/cm 2 on d 7. After sanitizer application, chlorine-based sanitizer removed bacteria in biofilm completely (0 cfu/cm 2 ) within 24 h post treatment whereas hydrogen peroxide-based sanitizer reduced the counts to 1.68 log 10 cfu/cm 2 (P < 0.05) by 48 h post sanitizer application. Control remained the same (P > 0.05). Results indicated that biofilm formation can occur quickly under suboptimal water condition on PVC surface, and sanitizer application helped mitigate already formed biofilm, yet chlorine proved to be more effective than hydrogen peroxide. © 2016 Poultry Science Association Inc.

  16. Enhanced balance associated with coordination training with stochastic resonance stimulation in subjects with functional ankle instability: an experimental trial.

    PubMed

    Ross, Scott E; Arnold, Brent L; Blackburn, J Troy; Brown, Cathleen N; Guskiewicz, Kevin M

    2007-12-17

    Ankle sprains are common injuries that often lead to functional ankle instability (FAI), which is a pathology defined by sensations of instability at the ankle and recurrent ankle sprain injury. Poor postural stability has been associated with FAI, and sports medicine clinicians rehabilitate balance deficits to prevent ankle sprains. Subsensory electrical noise known as stochastic resonance (SR) stimulation has been used in conjunction with coordination training to improve dynamic postural instabilities associated with FAI. However, unlike static postural deficits, dynamic impairments have not been indicative of ankle sprain injury. Therefore, the purpose of this study was to examine the effects of coordination training with or without SR stimulation on static postural stability. Improving postural instabilities associated with FAI has implications for increasing ankle joint stability and decreasing recurrent ankle sprains. This study was conducted in a research laboratory. Thirty subjects with FAI were randomly assigned to either a: 1) conventional coordination training group (CCT); 2) SR stimulation coordination training group (SCT); or 3) control group. Training groups performed coordination exercises for six weeks. The SCT group received SR stimulation during training, while the CCT group only performed coordination training. Single leg postural stability was measured after the completion of balance training. Static postural stability was quantified on a force plate using anterior/posterior (A/P) and medial/lateral (M/L) center-of-pressure velocity (COPvel), M/L COP standard deviation (COPsd), M/L COP maximum excursion (COPmax), and COP area (COParea). Treatment effects comparing posttest to pretest COP measures were highest for the SCT group. At posttest, the SCT group had reduced A/P COPvel (2.3 +/- 0.4 cm/s vs. 2.7 +/- 0.6 cm/s), M/L COPvel (2.6 +/- 0.5 cm/s vs. 2.9 +/- 0.5 cm/s), M/L COPsd (0.63 +/- 0.12 cm vs. 0.73 +/- 0.11 cm), M/L COPmax (1.76 +/- 0.25 cm vs. 1.98 +/- 0.25 cm), and COParea (0.13 +/- 0.03 cm2 vs. 0.16 +/- 0.04 cm2) than the pooled means of the CCT and control groups (P < 0.05). Reduced values in COP measures indicated postural stability improvements. Thus, six weeks of coordination training with SR stimulation enhanced postural stability. Future research should examine the use of SR stimulation for decreasing recurrent ankle sprain injury in physically active individuals with FAI.

  17. Enhanced balance associated with coordination training with stochastic resonance stimulation in subjects with functional ankle instability: an experimental trial

    PubMed Central

    Ross, Scott E; Arnold, Brent L; Blackburn, J Troy; Brown, Cathleen N; Guskiewicz, Kevin M

    2007-01-01

    Background Ankle sprains are common injuries that often lead to functional ankle instability (FAI), which is a pathology defined by sensations of instability at the ankle and recurrent ankle sprain injury. Poor postural stability has been associated with FAI, and sports medicine clinicians rehabilitate balance deficits to prevent ankle sprains. Subsensory electrical noise known as stochastic resonance (SR) stimulation has been used in conjunction with coordination training to improve dynamic postural instabilities associated with FAI. However, unlike static postural deficits, dynamic impairments have not been indicative of ankle sprain injury. Therefore, the purpose of this study was to examine the effects of coordination training with or without SR stimulation on static postural stability. Improving postural instabilities associated with FAI has implications for increasing ankle joint stability and decreasing recurrent ankle sprains. Methods This study was conducted in a research laboratory. Thirty subjects with FAI were randomly assigned to either a: 1) conventional coordination training group (CCT); 2) SR stimulation coordination training group (SCT); or 3) control group. Training groups performed coordination exercises for six weeks. The SCT group received SR stimulation during training, while the CCT group only performed coordination training. Single leg postural stability was measured after the completion of balance training. Static postural stability was quantified on a force plate using anterior/posterior (A/P) and medial/lateral (M/L) center-of-pressure velocity (COPvel), M/L COP standard deviation (COPsd), M/L COP maximum excursion (COPmax), and COP area (COParea). Results Treatment effects comparing posttest to pretest COP measures were highest for the SCT group. At posttest, the SCT group had reduced A/P COPvel (2.3 ± 0.4 cm/s vs. 2.7 ± 0.6 cm/s), M/L COPvel (2.6 ± 0.5 cm/s vs. 2.9 ± 0.5 cm/s), M/L COPsd (0.63 ± 0.12 cm vs. 0.73 ± 0.11 cm), M/L COPmax (1.76 ± 0.25 cm vs. 1.98 ± 0.25 cm), and COParea (0.13 ± 0.03 cm2 vs. 0.16 ± 0.04 cm2) than the pooled means of the CCT and control groups (P < 0.05). Conclusion Reduced values in COP measures indicated postural stability improvements. Thus, six weeks of coordination training with SR stimulation enhanced postural stability. Future research should examine the use of SR stimulation for decreasing recurrent ankle sprain injury in physically active individuals with FAI. PMID:18086314

  18. Clean Transfer of Wafer-Scale Graphene via Liquid Phase Removal of Polycyclic Aromatic Hydrocarbons.

    PubMed

    Kim, Hyun Ho; Kang, Boseok; Suk, Ji Won; Li, Nannan; Kim, Kwang S; Ruoff, Rodney S; Lee, Wi Hyoung; Cho, Kilwon

    2015-05-26

    Pentacene (C22H14), a polycyclic aromatic hydrocarbon, was used as both supporting and sacrificing layers for the clean and doping-free graphene transfer. After successful transfer of graphene to a target substrate, the pentacene layer was physically removed from the graphene surface by using intercalating organic solvent. This solvent-mediated removal of pentacene from graphene surface was investigated by both theoretical calculation and experimental studies with various solvents. The uses of pentacene and appropriate intercalation solvent enabled graphene transfer without forming a residue from the supporting layer. Such residues tend to cause charged impurity scattering and unintentional graphene doping effects. As a result, this clean graphene exhibited extremely homogeneous surface potential profiles over a large area. A field-effect transistor fabricated using this graphene displayed a high hole (electron) mobility of 8050 cm(2)/V·s (9940 cm(2)/V·s) with a nearly zero Dirac point voltage.

  19. Development of land-use regression models for exposure assessment to ultrafine particles in Rome, Italy

    NASA Astrophysics Data System (ADS)

    Cattani, Giorgio; Gaeta, Alessandra; di Menno di Bucchianico, Alessandro; de Santis, Antonella; Gaddi, Raffaela; Cusano, Mariacarmela; Ancona, Carla; Badaloni, Chiara; Forastiere, Francesco; Gariazzo, Claudio; Sozzi, Roberto; Inglessis, Marco; Silibello, Camillo; Salvatori, Elisabetta; Manes, Fausto; Cesaroni, Giulia; The Viias Study Group

    2017-05-01

    The health effects of long-term exposure to ultrafine particles (UFPs) are poorly understood. Data on spatial contrasts in ambient ultrafine particles (UFPs) concentrations are needed with fine resolution. This study aimed to assess the spatial variability of total particle number concentrations (PNC, a proxy for UFPs) in the city of Rome, Italy, using land use regression (LUR) models, and the correspondent exposure of population here living. PNC were measured using condensation particle counters at the building facade of 28 homes throughout the city. Three 7-day monitoring periods were carried out during cold, warm and intermediate seasons. Geographic Information System predictor variables, with buffers of varying size, were evaluated to model spatial variations of PNC. A stepwise forward selection procedure was used to develop a "base" linear regression model according to the European Study of Cohorts for Air Pollution Effects project methodology. Other variables were then included in more enhanced models and their capability of improving model performance was evaluated. Four LUR models were developed. Local variation in UFPs in the study area can be largely explained by the ratio of traffic intensity and distance to the nearest major road. The best model (adjusted R2 = 0.71; root mean square error = ±1,572 particles/cm³, leave one out cross validated R2 = 0.68) was achieved by regressing building and street configuration variables against residual from the "base" model, which added 3% more to the total variance explained. Urban green and population density in a 5,000 m buffer around each home were also relevant predictors. The spatial contrast in ambient PNC across the large conurbation of Rome, was successfully assessed. The average exposure of subjects living in the study area was 16,006 particles/cm³ (SD 2165 particles/cm³, range: 11,075-28,632 particles/cm³). A total of 203,886 subjects (16%) lives in Rome within 50 m from a high traffic road and they experience the highest exposure levels (18,229 particles/cm³). The results will be used to estimate the long-term health effects of ultrafine particle exposure of participants in Rome.

  20. Effect of different plant spacing on the production of cauliflower (Brassica oleraceae var. Botrytis) under the agro-climatic conditions of D.I. Khan.

    PubMed

    Mujeeb-ur-Rahman; Iqbal, Muhammad; Jilani, Muhammad Saleem; Waseem, Kashif

    2007-12-15

    A research project to evaluate the effect of different plant spacing on the production of cauliflower was conducted at Horticulture Research Area, Faculty of Agriculture, Gomal University, Dera Ismail Khan, NWFP, Pakistan. Six different plant spacing viz., 30, 35, 40, 45, 50 and 55 cm were used. The results revealed significant variations in all the parameters and amongst various plant spacing, 45 cm spacing showed the best response for all the parameters. Maximum plant height (49.33 cm), curd diameter (19.13 cm), maximum curd weight (1.23 kg plant(-1)) and yield (30.77 t ha(-1)) were recorded in the plots where the plants were spaced 45 cm apart.

  1. Heat-induced changes to lipid molecular structure in Vimy flaxseed: Spectral intensity and molecular clustering

    NASA Astrophysics Data System (ADS)

    Yu, Peiqiang; Damiran, Daalkhaijav

    2011-06-01

    Autoclaving was used to manipulate nutrient utilization and availability. The objectives of this study were to characterize any changes of the functional groups mainly associated with lipid structure in flaxseed ( Linum usitatissimum, cv. Vimy), that occurred on a molecular level during the treatment process using infrared Fourier transform molecular spectroscopy. The parameters included lipid CH 3 asymmetric (ca. 2959 cm -1), CH 2 asymmetric (ca. 2928 cm -1), CH 3 symmetric (ca. 2871 cm -1) and CH 2 symmetric (ca. 2954 cm -1) functional groups, lipid carbonyl C dbnd O ester group (ca. 1745 cm -1), lipid unsaturation group (CH attached to C dbnd C) (ca. 3010 cm -1) as well as their ratios. Hierarchical cluster analysis (CLA) and principal components analysis (PCA) were conducted to identify molecular spectral differences. Flaxseed samples were kept raw for the control or autoclaved in batches at 120 °C for 20, 40 or 60 min for treatments 1, 2 and 3, respectively. Molecular spectral analysis of lipid functional group ratios showed a significant decrease ( P < 0.05) in the CH 2 asymmetric to CH 3 asymmetric stretching band peak intensity ratios for the flaxseed. There were linear and quadratic effects ( P < 0.05) of the treatment time from 0, 20, 40 and 60 min on the ratios of the CH 2 asymmetric to CH 3 asymmetric stretching vibration intensity. Autoclaving had no significant effect ( P > 0.05) on lipid carbonyl C dbnd O ester group and lipid unsaturation group (CH attached to C dbnd C) (with average spectral peak area intensities of 138.3 and 68.8 IR intensity units, respectively). Multivariate molecular spectral analyses, CLA and PCA, were unable to make distinctions between the different treatment original spectra at the CH 3 and CH 2 asymmetric and symmetric region (ca. 2988-2790 cm -1). The results indicated that autoclaving had an impact to the mid-infrared molecular spectrum of flaxseed to identify heat-induced changes in lipid conformation. A future study is needed to quantify the relationship between lipid molecular structure changes and functionality/availability.

  2. Exclusion Area Radiation Release during the MIT Reactor Design Basis Accident.

    DTIC Science & Technology

    1983-05-06

    Concrete Wall 116 6.2 Concrete Albedo Dose 121 6.3 Steel Door Scattering Dose 124 7.1 Total Dose Results 133 A.1 Values of N /NO for Neutron -Capture...plate fuel elements arranged in x a compact hexagonal core. This core design maximizes the neutron flux in the DO2 reflector region where numerous...sec) V = Volume of the fuel (cm 3 f Ef = Macroscopic fission cross section (cm ) = Thermal neutron flux ( neutrons /cm2 - sec) = Core-averaged value Yi

  3. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model

    PubMed Central

    Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason

    2018-01-01

    Introduction: Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Methods: Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Results: Increasing distraction led to greater Spinal canal area. From 4.27 cm2 to 5.72 cm2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm2 to 3.22 cm2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). Discussion: For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. PMID:29727270

  4. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model.

    PubMed

    Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason

    2018-01-01

    Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Increasing distraction led to greater Spinal canal area. From 4.27 cm 2 to 5.72 cm 2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm 2 to 3.22 cm 2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. © The Authors, published by EDP Sciences, 2018.

  5. Velopharyngeal port status during classical singing.

    PubMed

    Tanner, Kristine; Roy, Nelson; Merrill, Ray M; Power, David

    2005-12-01

    This investigation was undertaken to examine the status of the velopharyngeal (VP) port during classical singing. Using aeromechanical instrumentation, nasal airflow (mL/s), oral pressure (cm H2O), and VP orifice area estimates (cm2) were studied in 10 classically trained sopranos during singing and speaking. Each participant sang and spoke 3 nonsense words-/hampa/, /himpi/, and /humpu/-at 3 loudness levels (loud vs. comfortable vs. soft) and 3 pitches (high vs. comfortable vs. low), using a within-subject experimental design including all possible combinations. In general, nasal airflow, oral pressure, and VP area estimates were significantly greater for singing as compared to speech, and nasal airflow was observed during non-nasal sounds in all participants. Anticipatory nasal airflow was observed in 9 of 10 participants for singing and speaking and was significantly greater during the first vowel in /hampa/ versus /himpi/ and /humpu/. The effect of vowel height on nasal airflow was also significantly influenced by loudness and pitch. The results from this investigation indicate that at least some trained singers experience regular VP opening during classical singing. Vowel height seems to influence this effect. Future research should consider the effects of voice type, gender, experience level, performance ability, and singing style on VP valving in singers.

  6. Lactic-fermented egg white improves visceral fat obesity in Japanese subjects-double-blind, placebo-controlled study.

    PubMed

    Matsuoka, Ryosuke; Kamachi, Keiko; Usuda, Mika; Wang, Wei; Masuda, Yasunobu; Kunou, Masaaki; Tanaka, Akira; Utsunomiya, Kazunori

    2017-12-08

    It was reported that egg white protein (EWP) reduced body fat in rats. We developed a lactic-fermented egg white (LE) that facilitates the consumption of egg whites by fermenting them with lactobacillus, and were able to study their intake in humans. In this double-blind, placebo-controlled design, we evaluated the effect of LE on visceral fat area (VFA). Participants included 37 adult males and females aged ≥40 years (VFA at navel ≥100 cm 2 ). They were divided into two groups: the control group and the LE group. The control and LE groups consumed drinks containing whey and LE, respectively, for 12 weeks (providing 8 g protein/day). VFA was measured at baseline and at week 12 of intake. Abdominal girth was measured at baseline and at weeks 6 and 12. LE intake decreased VFA significantly compared with baseline (-8.89 cm 2 , p < 0.05), and VFA was significantly lower than that in the control group (+1.71 cm 2 , p < 0.05). The LE group showed significant improvement in the ratio of visceral to subcutaneous fat area compared with baseline and the control group (p < 0.05). The results demonstrated that LE reduces VFA and improves the ratio of visceral to subcutaneous fat area. As other measurement items were not influenced, we concluded that LE improves visceral fat obesity. This clinical trial was retrospectively registered with the University hospital Medical Information Network (UMIN) Center, ( UMIN000026949 ; registered on 11/04/2017; http://www.umin.ac.jp /).

  7. Two-dimensional electron gases in MgZnO/ZnO and ZnO/MgZnO/ZnO heterostructures grown by dual ion beam sputtering

    NASA Astrophysics Data System (ADS)

    Singh, Rohit; Arif Khan, Md; Sharma, Pankaj; Than Htay, Myo; Kranti, Abhinav; Mukherjee, Shaibal

    2018-04-01

    This work reports on the formation of high-density (~1013-1014 cm-2) two-dimensional electron gas (2DEG) in ZnO-based heterostructures, grown by a dual ion beam sputtering system. We probe 2DEG in bilayer MgZnO/ZnO and capped ZnO/MgZnO/ZnO heterostructures utilizing MgZnO barrier layers with varying thickness and Mg content. The effect of the ZnO cap layer thickness on the ZnO/MgZnO/ZnO heterostructure is also studied. Hall measurements demonstrate that the addition of a 5 nm ZnO cap layer results in an enhancement of the 2DEG density by about 1.5 times compared to 1.11 × 1014 cm-2 for the uncapped bilayer heterostructure with the same 30 nm barrier thickness and 30 at.% Mg composition in the barrier layer. From the low-temperature Hall measurement, the sheet carrier concentration and mobility are both found to be independent of the temperature. The capacitance-voltage measurement suggests a carrier density of ~1020 cm-3, confined in 2DEG at the MgZnO/ZnO heterointerface. The results presented are significant for the optimization of 2DEG for the eventual realization of cost-effective and large-area MgZnO/ZnO-based high-electron-mobility transistors.

  8. Physiological cross-sectional area of human leg muscles based on magnetic resonance imaging

    NASA Technical Reports Server (NTRS)

    Fukunaga, T.; Roy, R. R.; Shellock, F. G.; Hodgson, J. A.; Day, M. K.; Lee, P. L.; Kwong-Fu, H.; Edgerton, V. R.

    1992-01-01

    Magnetic resonance imaging techniques were used to determine the physiological cross-sectional areas (PCSAs) of the major muscles or muscle groups of the lower leg. For 12 healthy subjects, the boundaries of each muscle or muscle group were digitized from images taken at 1-cm intervals along the length of the leg. Muscle volumes were calculated from the summation of each anatomical CSA (ACSA) and the distance between each section. Muscle length was determined as the distance between the most proximal and distal images in which the muscle was visible. The PCSA of each muscle was calculated as muscle volume times the cosine of the angle of fiber pinnation divided by fiber length, where published fiber length:muscle length ratios were used to estimate fiber lengths. The mean volumes of the major plantarflexors were 489, 245, and 140 cm3 for the soleus and medial (MG) and lateral (LG) heads of the gastrocnemius. The mean PCSA of the soleus was 230 cm2, about three and eight times larger than the MG (68 cm2) and LG (28 cm2), respectively. These PCSA values were eight (soleus), four (MG), and three (LG) times larger than their respective maximum ACSA. The major dorsiflexor, the tibialis anterior (TA), had a muscle volume of 143 cm2, a PCSA of 19 cm2, and an ACSA of 9 cm2. With the exception of the soleus, the mean fiber length of all subjects was closely related to muscle volume across muscles. The soleus fibers were unusually short relative to the muscle volume, thus potentiating its force potential.(ABSTRACT TRUNCATED AT 250 WORDS).

  9. Efficacy of the use of two simultaneously TENS devices for fibromyalgia pain.

    PubMed

    Lauretti, Gabriela Rocha; Chubaci, Eliana Fazuoli; Mattos, Anita Leocadia

    2013-08-01

    Fibromyalgia is characterized by a range of symptoms that include muscle pain, fatigue and sleep disorders. Transcutaneous electrical nerve stimulation (TENS) is an established method for pain relief. The purpose of the study was to evaluate the effectiveness and safety of the use of two simultaneously new TENS devices for fibromyalgia pain. After Ethics approval and informed consent, 39 patients were prospectively divided into three groups to evaluate TENS device, applied simultaneously in each patient: (1) at the lower back (perpendicular to the vertebrae canal, at the level of the 5th lumbar vertebrae) and (2) centrally above and below the space between the C7 and T1 spinous processes. The devices were applied for 20 min at 12-h interval during 7 consecutive days. For the placebo group (PG), the devices did not transmitted electrical stimulus. The single-TENS group (STG) (n = 13) had one active and one placebo TENS. The DTG applied both active TENS devices at the low back and cervical areas. Diclofenac was used as rescue analgesic. The efficacy measures were pain relief, reduction in use of daily analgesic tablets, quality of sleep and fatigue. The evaluation within groups revealed that patients from DPG refereed no pain relief when compared to their previous VAS pain score (8 cm, p > 0.05), while patients from the STG refereed improvement of 2.5 cm in the pain VAS (previous 8.5 cm compared to 6 cm after treatment) (p < 0.05), and the DPG refereed daily maintained reduction of 4 cm in the VAS pain (previous 8.5-4.3 cm) (p < 0.02). Concurrent daily consumption of analgesic tablets was reduced in both STG (p < 0.05) and DTG (p < 0.02). Comparison among groups revealed that analgesia, as well as quality of sleep and disposition, was DTG > STG > PG (p < 0.05). Participants subjectively found the active device useful. While the application of a single active TENS improved pain relief in fibromyalgia pain, pain and fatigue were further improved when two active devices were simultaneously applied at the low back and cervical area, with no side effects.

  10. Combined Use of a Patient Dose Monitoring System and a Real-Time Occupational Dose Monitoring System for Fluoroscopically Guided Interventions.

    PubMed

    Heilmaier, Christina; Kara, Levent; Zuber, Niklaus; Berthold, Christian; Weishaupt, Dominik

    2016-04-01

    To determine the effect on patient radiation exposure of the combined use of a patient dose monitoring system and real-time occupational dose monitoring during fluoroscopically guided interventions (FGIs). Patient radiation exposure, in terms of the kerma area product (KAP; Gy ∙ cm(2)), was measured in period 1 with a patient dose monitoring system, and a real-time occupational dose monitoring system was additionally applied in period 2. Mean/median KAP in 19 different types of FGIs was analyzed in both periods for two experienced interventional radiologists combined as well as individually. Patient dose and occupational dose were correlated, applying Pearson and Spearman correlation coefficients. Although FGIs were similar in numbers and types over both periods, a substantial decrease was found for period 2 in total mean ± SD/median KAP for both operators together (period 1, 47 Gy ∙ cm(2) ± 67/41 Gy ∙ cm(2); period 2, 37 Gy ∙ cm(2) ± 69/34 Gy ∙ cm(2)) as well as for each individual operator (for all, P < .05). Overall, KAP declined considerably in 15 of 19 types of FGIs in period 2. Mean accumulated dose per intervention was 4.6 µSv, and mean dose rate was 0.24 mSv/h. There was a strong positive correlation between patient and occupational dose (r = 0.88). Combined use of a patient dose monitoring system and a real-time occupational dose monitoring system in FGIs significantly lessens patient and operator doses. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  11. Impact of Cubic Pin Finned Surface Structure Geometry upon Spray Cooling Heat Transfer

    NASA Technical Reports Server (NTRS)

    Silk, Eric A.; Kim, Jungho; Kiger, Ken

    2005-01-01

    Experiments were conducted to study the effects of enhanced surface structures on heat flux using spray cooling. The surface enhancements consisted of cubic pin fins machined on the top surface of copper heater blocks. The structure height, pitch, and width were parametrically vaned. Each copper block had a projected cross-sectional area of 2.0 sq cm. Measurements were also obtained on a heater block with a flat surface for baseline comparison purposes. A 2 x 2 nozzle array was used with PF-5060 as the working fluid. Thermal performance data were obtained under nominally degassed (chamber pressure of 41.4 kPa) and gassy conditions (chamber with N2 gas at 100.7 kPa) with a bulk fluid temperature of 20.5 C. Results for both the degassed and gassy cases show that structure width and separation distance have a dominant effect upon the heat transfer for the size ranges used. Cubic pin fin height had little impact upon heat flux. The maximum critical heat flux (CHF) attained for any of the surfaces was 121 W/sq cm, giving an enhancement of 51% relative to the flat surface case under nominally degassed conditions. The gassy case had a maximum CHF of 149 W/sq cm, giving an enhancement of 38% relative to the flat surface case.

  12. Conical Tungsten Tips as Substrates for the Preparation of Ultramicroelectrodes

    PubMed Central

    Hermans, Andre; Wightman, R. Mark

    2008-01-01

    Here we describe a simple method to prepare voltammetric microelectrodes using tungsten wires as a substrate. Tungsten wires have high tensile modulus and enable the fabrication of electrodes that have small dimensions overall while retaining rigidity. In this work, 125 μm tungsten wires with a conical tip were employed. For the preparation of gold or platinum ultramicroelectrodes, commercial tungsten microelectrodes, completely insulated except at the tip, were used as substrates. Following removal of oxides from the exposed tungsten, platinum or gold was electroplated yielding surfaces with an electroactive area of between 1×10−6 cm2 to 2×10−6 cm2. Carbon surfaces on the etched tip of tungsten microwires were prepared by coating with photoresist followed by pyrolysis. The entire electrode was then insulated with Epoxylite except the tip yielding an exposed carbon surface with an area of around 4×10−6 cm2 to 6×10−6 cm2. All three types of ultramicroelectrodes fabricated on the tungsten wire had similar electrochemical behavior to electrodes fabricated from wires or fibers insulated with glass tubes. PMID:17129002

  13. Snow distribution throughout small subalpine catchment post-insect infestation of spruce and pine beetle.

    NASA Astrophysics Data System (ADS)

    Beverly, D.; Ewers, B. E.; Hyde, K.; Ohara, N.; Speckman, H. N.

    2015-12-01

    High elevation watersheds of the Rocky Mountains region contribute over 70% of the streamflow needed for infrastructure, agriculture, and ecological processes. Snow-water yields are heterogeneous in space and time and are driven by a multitude of snow distribution processes, including snowpack evolution driven by physical and biological factors. Quantifying heterogeneity of snowpack is further complicated by vegetation perturbations; much of the Rocky Mountains have experienced significant tree mortality due to bark beetle outbreaks. Reduction of living crown area decreases canopy interception while increasing radiation to snow surfaces, which alters snowpack distribution throughout the catchment. We hypothesize that, in a complex watershed, topographic variation (i.e., slope and aspect) will have a greater effect on snowpack evolution and distribution than densities of canopy mortality due to beetle infestation. The 120 ha No Name watershed, located in southern Wyoming at 3000 m elevation was divided into twenty-one 175 m2 parcels, in which plots were randomly assigned within each parcel. Peak snow was measured in April; in the 50 m2 plots, depths were measured every 2 m along north-south and east-west transects. Twenty-one snow pits were excavated to quantify snow densities in 10 cm increments throughout the pit profile. Forest inventories occurred the following summer. Peak snowpack levels occurred in April with mean depth of 92.3 ­­± 2.4 cm and peak SWE of 34.0 ± 0.84 cm. Binary decision trees accounted for 63% of the variability after including topographic indices, beetle condition of the trees, LAI, and basal area. Snow depth showed a slight positive relationship with increased in beetle mortality on slopes less than 11 degrees. Overall, topographic indices are greater drivers for snow distributions compared to effects of tree mortality.

  14. Clinical significance of incomplete tricuspid valve closure seen on two-dimensional echocardiography.

    PubMed

    Gibson, T C; Foale, R A; Guyer, D E; Weyman, A E

    1984-11-01

    Incomplete closure of the tricuspid valve without apparent cusp disease was noted on two-dimensional echocardiography in 31 patients. This abnormality was defined as a failure of the tricuspid valve leaflet tips to reach the plane of the tricuspid valve anulus by at least 1 cm in the standard apical four chamber view at the point of maximal systolic closure. This resulted in a final systolic leaflet position deeper within the right ventricular cavity than is normally seen. The finding was present in the following diagnostic subgroups: Group A, pulmonary hypertension (11 patients); Group B, rheumatic heart disease (4 patients); Group C, dilated cardiomyopathy (9 patients) and Group D, previous myocardial infarction (7 patients). Right atrial, right ventricular and tricuspid anulus measurements were made and compared with those from a group of 67 normal subjects. The results were as follows: right atrial endsystolic area = 27.2 +/- 8.6 cm2 (normal = 13.4 +/- 2.0); right ventricular end-systolic area = 25.6 +/- 8.7 cm2 (normal = 10.9 +/- 2.9); right ventricular end-diastolic area = 31.5 +/- 9.1 cm2 (normal = 20.1 +/- 4.9) and tricuspid valve anular end-systolic dimension = 4.0 +/- 0.6 cm (normal = 2.2 +/- 0.3). The differences from the normal data were all statistically significant (p less than 0.001). Incomplete closure of the tricuspid valve, although a nonspecific diagnostic finding, is primarily associated with right-sided chamber enlargement. Tricuspid regurgitation may be present. The mechanism could be related to geometric changes in valve apparatus dynamics secondary to right-sided cardiac enlargement and tricuspid valve anular dilation.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Validation of a DIXON-based fat quantification technique for the measurement of visceral fat using a CT-based reference standard.

    PubMed

    Heckman, Katherine M; Otemuyiwa, Bamidele; Chenevert, Thomas L; Malyarenko, Dariya; Derstine, Brian A; Wang, Stewart C; Davenport, Matthew S

    2018-06-27

    The purpose of the study is to determine whether a novel semi-automated DIXON-based fat quantification algorithm can reliably quantify visceral fat using a CT-based reference standard. This was an IRB-approved retrospective cohort study of 27 subjects who underwent abdominopelvic CT within 7 days of proton density fat fraction (PDFF) mapping on a 1.5T MRI. Cross-sectional visceral fat area per slice (cm 2 ) was measured in blinded fashion in each modality at intervertebral disc levels from T12 to L4. CT estimates were obtained using a previously published semi-automated computational image processing system that sums pixels with attenuation - 205 to - 51 HU. MR estimates were obtained using two novel semi-automated DIXON-based fat quantification algorithms that measure visceral fat area by spatially regularizing non-uniform fat-only signal intensity or de-speckling PDFF 2D images and summing pixels with PDFF ≥ 50%. Pearson's correlations and Bland-Altman analyses were performed. Visceral fat area per slice ranged from 9.2 to 429.8 cm 2 for MR and from 1.6 to 405.5 cm 2 for CT. There was a strong correlation between CT and MR methods in measured visceral fat area across all studied vertebral body levels (r = 0.97; n = 101 observations); the least (r = 0.93) correlation was at T12. Bland-Altman analysis revealed a bias of 31.7 cm 2 (95% CI [- 27.1]-90.4 cm 2 ), indicating modestly higher visceral fat assessed by MR. MR- and CT-based visceral fat quantification are highly correlated and have good cross-modality reliability, indicating that visceral fat quantification by either method can yield a stable and reliable biomarker.

  16. A MAPS Based Micro-Vertex Detector for the STAR Experiment

    DOE PAGES

    Schambach, Joachim; Anderssen, Eric; Contin, Giacomo; ...

    2015-06-18

    For the 2014 heavy ion run of RHIC a new micro-vertex detector called the Heavy Flavor Tracker (HFT) was installed in the STAR experiment. The HFT consists of three detector subsystems with various silicon technologies arranged in 4 approximately concentric cylinders close to the STAR interaction point designed to improve the STAR detector’s vertex resolution and extend its measurement capabilities in the heavy flavor domain. The two innermost HFT layers are placed at radii of 2.8 cm and 8 cm from the beam line. These layers are constructed with 400 high resolution sensors based on CMOS Monolithic Active Pixel Sensormore » (MAPS) technology arranged in 10-sensor ladders mounted on 10 thin carbon fiber sectors to cover a total silicon area of 0.16 m 2. Each sensor of this PiXeL (“PXL”) sub-detector combines a pixel array of 928 rows and 960 columns with a 20.7 μm pixel pitch together with front-end electronics and zero-suppression circuitry in one silicon die providing a sensitive area of ~3.8 cm 2. This sensor architecture features 185.6 μs readout time and 170 mW/cm 2 power dissipation. This low power dissipation allows the PXL detector to be air-cooled, and with the sensors thinned down to 50 μm results in a global material budget of only 0.4% radiation length per layer. A novel mechanical approach to detector insertion allows us to effectively install and integrate the PXL sub-detector within a 12 hour period during an on-going multi-month data taking period. The detector requirements, architecture and design, as well as the performance after installation, are presented in this paper.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schambach, Joachim; Anderssen, Eric; Contin, Giacomo

    For the 2014 heavy ion run of RHIC a new micro-vertex detector called the Heavy Flavor Tracker (HFT) was installed in the STAR experiment. The HFT consists of three detector subsystems with various silicon technologies arranged in 4 approximately concentric cylinders close to the STAR interaction point designed to improve the STAR detector’s vertex resolution and extend its measurement capabilities in the heavy flavor domain. The two innermost HFT layers are placed at radii of 2.8 cm and 8 cm from the beam line. These layers are constructed with 400 high resolution sensors based on CMOS Monolithic Active Pixel Sensormore » (MAPS) technology arranged in 10-sensor ladders mounted on 10 thin carbon fiber sectors to cover a total silicon area of 0.16 m 2. Each sensor of this PiXeL (“PXL”) sub-detector combines a pixel array of 928 rows and 960 columns with a 20.7 μm pixel pitch together with front-end electronics and zero-suppression circuitry in one silicon die providing a sensitive area of ~3.8 cm 2. This sensor architecture features 185.6 μs readout time and 170 mW/cm 2 power dissipation. This low power dissipation allows the PXL detector to be air-cooled, and with the sensors thinned down to 50 μm results in a global material budget of only 0.4% radiation length per layer. A novel mechanical approach to detector insertion allows us to effectively install and integrate the PXL sub-detector within a 12 hour period during an on-going multi-month data taking period. The detector requirements, architecture and design, as well as the performance after installation, are presented in this paper.« less

  18. WEED SURVEYING OF PHACELIA (PHACELIA TANACETIFOLIA L.) AND EVALUATING THE EFFICIENCY OF THE WEED CONTROL.

    PubMed

    Horváth, E; Szabó, R

    2014-01-01

    The experiment was set up in an area of 9 ha that was split into 4 plots: in plot 1 the row spacing was 12 cm and the seeding rate was 10 kg; in plot 2 the row spacing was 24 cm and the seeding rate was 10 kg; in plot 3 the row spacing was 24 cm and the seeding rate was 8 kg; in plot 4 the row spacing was 12 cm and the seeding rate was 8 kg. After the weed surveying, the total weed coverage was established as follows: in plot 1 the total weed coverage was 11.34%, in plot 2 it was 12.3%, in plot 3 it was 18%, and in plot 4 the total weed coverage was 15%. Based on the weed survey, on the test area the following dicotyledon weeds belonging to the T4 Raunkiaer plant life-form category occupied the highest percentage: heal-all, black-bindweed, goosefoot. The proportion of the perennial dicotyledons: field bindweed (G3), tuberous pea (G1), white campion (H3) was negligible. In all four cases the weed control was executed using the same herbicide in the same doses and with regard to the weed species it showed the same level of efficiency. The smaller row spacing and higher seeding rate has a beneficial effect on the weed suppressing capacity of the crop, the crop's weed suppressing capacity is better and the development of the weeds becomes worse.

  19. Personal exposure to ultrafine particles: the influence of time-activity patterns.

    PubMed

    Buonanno, G; Stabile, L; Morawska, L

    2014-01-15

    Exposure to ultrafine particles (UFPs) is deemed to be a major risk affecting human health. Therefore, airborne particle studies were performed in the recent years to evaluate the most critical micro-environments, as well as identifying the main UFP sources. Nonetheless, in order to properly evaluate the UFP exposure, personal monitoring is required as the only way to relate particle exposure levels to the activities performed and micro-environments visited. To this purpose, in the present work, the results of experimental analysis aimed at showing the effect of the time-activity patterns on UFP personal exposure are reported. In particular, 24 non-smoking couples (12 during winter and summer time, respectively), comprised of a man who worked full-time and a woman who was a homemaker, were analyzed using personal particle counter and GPS monitors. Each couple was investigated for a 48-h period, during which they also filled out a diary reporting the daily activities performed. Time activity patterns, particle number concentration exposure and the related dose received by the participants, in terms of particle alveolar-deposited surface area, were measured. The average exposure to particle number concentration was higher for women during both summer and winter (Summer: women 1.8 × 10(4) part. cm(-3); men 9.2 × 10(3) part. cm(-3); Winter: women 2.9 × 10(4) part. cm(-3); men 1.3 × 10(4) part. cm(-3)), which was likely due to the time spent undertaking cooking activities. Staying indoors after cooking also led to higher alveolar-deposited surface area dose for both women and men during the winter time (9.12 × 10(2) and 6.33 × 10(2) mm(2), respectively), when indoor ventilation was greatly reduced. The effect of cooking activities was also detected in terms of women's dose intensity (dose per unit time), being 8.6 and 6.6 in winter and summer, respectively. On the contrary, the highest dose intensity activity for men was time spent using transportation (2.8 in both winter and summer). © 2013.

  20. Maggots as a wound debridement agent for chronic venous leg ulcers under graduated compression bandages: A randomised controlled trial.

    PubMed

    Davies, C E; Woolfrey, G; Hogg, N; Dyer, J; Cooper, A; Waldron, J; Bulbulia, R; Whyman, M R; Poskitt, K R

    2015-12-01

    Slough in chronic venous leg ulcers may be associated with delayed healing. The purpose of this study was to assess larval debridement in chronic venous leg ulcers and to assess subsequent effect on healing. All patients with chronic leg ulcers presenting to the leg ulcer service were evaluated for the study. Exclusion criteria were: ankle brachial pressure indices <0.85 or >1.25, no venous reflux on duplex and <20% of ulcer surface covered with slough. Participants were randomly allocated to either 4-layer compression bandaging alone or 4-layer compression bandaging + larvae. Surface areas of ulcer and slough were assessed on day 4; 4-layer compression bandaging was then continued and ulcer size was measured every 2 weeks for up to 12 weeks. A total of 601 patients with chronic leg ulcers were screened between November 2008 and July 2012. Of these, 20 were randomised to 4-layer compression bandaging and 20 to 4-layer compression bandaging + larvae. Median (range) ulcer size was 10.8 (3-21.3) cm(2) and 8.1 (4.3-13.5) cm(2) in the 4-layer compression bandaging and 4-layer compression bandaging + larvae groups, respectively (Mann-Whitney U test, P = 0.184). On day 4, median reduction in slough area was 3.7 cm(2) in the 4-layer compression bandaging group (P < 0.05) and 4.2 cm(2) (P < 0.001) in the 4-layer compression bandaging + larvae group. Median percentage area reduction of slough was 50% in the 4-layer compression bandaging group and 84% in the 4-layer compression bandaging + larvae group (Mann-Whitney U test, P < 0.05). The 12-week healing rate was 73% and 68% in the 4-layer compression bandaging and 4-layer compression bandaging + larvae groups, respectively (Kaplan-Meier analysis, P = 0.664). Larval debridement therapy improves wound debridement in chronic venous leg ulcers treated with multilayer compression bandages. However, no subsequent improvement in ulcer healing was demonstrated. © The Author(s) 2014.

  1. Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng Yuanshui; Liu Yaxi; Zeidan, Omar

    Purpose: Neutron exposure is of concern in proton therapy, and varies with beam delivery technique, nozzle design, and treatment conditions. Uniform scanning is an emerging treatment technique in proton therapy, but neutron exposure for this technique has not been fully studied. The purpose of this study is to investigate the neutron dose equivalent per therapeutic dose, H/D, under various treatment conditions for uniform scanning beams employed at our proton therapy center. Methods: Using a wide energy neutron dose equivalent detector (SWENDI-II, ThermoScientific, MA), the authors measured H/D at 50 cm lateral to the isocenter as a function of proton range,more » modulation width, beam scanning area, collimated field size, and snout position. They also studied the influence of other factors on neutron dose equivalent, such as aperture material, the presence of a compensator, and measurement locations. They measured H/D for various treatment sites using patient-specific treatment parameters. Finally, they compared H/D values for various beam delivery techniques at various facilities under similar conditions. Results: H/D increased rapidly with proton range and modulation width, varying from about 0.2 mSv/Gy for a 5 cm range and 2 cm modulation width beam to 2.7 mSv/Gy for a 30 cm range and 30 cm modulation width beam when 18 Multiplication-Sign 18 cm{sup 2} uniform scanning beams were used. H/D increased linearly with the beam scanning area, and decreased slowly with aperture size and snout retraction. The presence of a compensator reduced the H/D slightly compared with that without a compensator present. Aperture material and compensator material also have an influence on neutron dose equivalent, but the influence is relatively small. H/D varied from about 0.5 mSv/Gy for a brain tumor treatment to about 3.5 mSv/Gy for a pelvic case. Conclusions: This study presents H/D as a function of various treatment parameters for uniform scanning proton beams. For similar treatment conditions, the H/D value per uncollimated beam size for uniform scanning beams was slightly lower than that from a passive scattering beam and higher than that from a pencil beam scanning beam, within a factor of 2. Minimizing beam scanning area could effectively reduce neutron dose equivalent for uniform scanning beams, down to the level close to pencil beam scanning.« less

  2. Application of Percutaneous Balloon Mitral Valvuloplasty in Patients of Rheumatic Heart Disease Mitral Stenosis Combined with Tricuspid Regurgitation

    PubMed Central

    Chen, Zhang-Qiang; Hong, Lang; Wang, Hong; Lu, Lin-Xiang; Yin, Qiu-Lin; Lai, Heng-Li; Li, Hua-Tai; Wang, Xiang

    2015-01-01

    Background: Tricuspid regurgitation (TR) is frequently associated with severe mitral stenosis (MS), the importance of significant TR was often neglected. However, TR influences the outcome of patients. The aim of this study was to investigate the efficacy and safety of percutaneous balloon mitral valvuloplasty (PBMV) procedure in rheumatic heart disease patients with mitral valve (MV) stenosis and tricuspid valve regurgitation. Methods: Two hundred and twenty patients were enrolled in this study due to rheumatic heart disease with MS combined with TR. Mitral balloon catheter made in China was used to expand MV. The following parameters were measured before and after PBMV: MV area (MVA), TR area (TRA), atrial pressure and diameter, and pulmonary artery pressure (PAP). The patients were followed for 6 months to 9 years. Results: After PBMV, the MVAs increased significantly (1.7 ± 0.3 cm2 vs. 0.9 ± 0.3 cm2, P < 0.01); TRA significantly decreased (6.3 ± 1.7 cm2 vs. 14.2 ± 6.5 cm2, P < 0.01), right atrial area (RAA) decreased significantly (21.5 ± 4.5 cm2 vs. 25.4 ± 4.3 cm2, P < 0.05), TRA/RAA (%) decreased significantly (29.3 ± 3.2% vs. 44.2 ± 3.6%, P < 0.01). TR velocity (TRV) and TR continue time (TRT) as well as TRV × TRT decreased significantly (183.4 ± 9.4 cm/s vs. 254.5 ± 10.7 cm/s, P < 0.01; 185.7 ± 13.6 ms vs. 238.6 ± 11.3 ms, P < 0.01; 34.2 ± 5.6 cm vs. 60.7 ± 8.5 cm, P < 0.01, respectively). The postoperative left atrial diameter (LAD) significantly reduced (41.3 ± 6.2 mm vs. 49.8 ± 6.8 mm, P < 0.01) and the postoperative right atrial diameter (RAD) significantly reduced (28.7 ± 5.6 mm vs. 46.5 ± 6.3 mm, P < 0.01); the postoperative left atrium pressure significantly reduced (15.6 ± 6.1 mmHg vs. 26.5 ± 6.6 mmHg, P < 0.01), the postoperative right atrial pressure decreased significantly (13.2 ± 2.4 mmHg vs. 18.5 ± 4.3 mmHg, P < 0.01). The pulmonary arterial pressure decreased significantly after PBMV (48.2 ± 10.3 mmHg vs. 60.6 ± 15.5 mmHg, P < 0.01). The symptom of chest tightness and short of breath obviously alleviated. All cases followed-up for 6 months to 9 years (average 75 ± 32 months), 2 patients with severe regurgitation died (1 case of massive cerebral infarction, and 1 case of heart failure after 6 years and 8 years, respectively), 2 cases lost access. At the end of follow-up, MVA has been reduced compared with the postoperative (1.4 ± 0.4 cm2 vs. 1.7 ± 0.3 cm2, P < 0.05); LAD slightly increased compared with the postoperative (45.2 ± 5.7 mm vs. 41.4 ± 6.3 mm, P < 0.05), RAD slightly also increased compared with the postoperative (36.1 ± 6.3 mm vs. 28.6 ± 5.5 mm, P < 0.05), but did not recover to the preoperative level. TRA slightly increased compared with the postoperative, but the difference was not statistically significant (P > 0.05). The PAP and left ventricular ejection fraction appeared no statistical difference compared with the postoperative (P > 0.05), the remaining patients without serious complications. Conclusions: PBMV is a safe and effective procedure for MS combined with TR in patients of rheumatic heart disease. It can alleviate the symptoms and reduce the size of TR. It can also improve the quality-of-life and prognosis. Its recent and mid-term efficacy is certain. While its long-term efficacy remains to be observed. PMID:26021504

  3. Resistance characterization of nickel sulfide electrodes in LiCl-containing molten salt electrolytes

    NASA Astrophysics Data System (ADS)

    Redey, L.; Vissers, D. R.

    The electrode kinetics of a high area loading: (545.6 mAh/cm(2) for the Ni reversible NiS transition), porous nickel sulfide electrode were studied under one-dimensional current distribution in a half-cell-type test arrangement. Area-specific resistance values (ASR/sub t/) were measured under wide variety of conditions: temperature, 450 to 490(0)C; current density, 0.01 to 3A/cm(2); and mechanical stress, 0.11 to 1.68 kg/cm(2). The ASR/sub t/ values were used for quantitative characterization of the ohmic-related and electrochemical-related resistances of the electrode bed. When cycled in the Ni reversible NiS transition range, the electrode showed good utilization and excellent power characteristics in an all-lithium-cation (LiF-LiCl-LiBr) electrolyte. Capability of continuous cycling at high rates (up to 800 mA/cm(12) was demonstrated. The performance of the electrode was also found to be dependent on the mechanical stress developed in the electrode.

  4. Silicon-on-ceramic Process: Silicon Sheet Growth and Device Development for the Large-area Silicon Sheet and Cell Development Tasks of the Low-cost Solar Array Project

    NASA Technical Reports Server (NTRS)

    Chapman, P. W.; Zook, J. D.; Heaps, J. D.; Grung, B. L.; Koepke, B.; Schuldt, S. B.

    1979-01-01

    Significant progress is reported in fabricating a 4 sq cm cell having a 10.1 percent conversion efficiency and a 10 sq cm cell having a 9.2 percent conversion efficiency. The continuous (SCIM) coater succeeded in producing a 16 sq cm coating exhibiting unidirectional solidification and large grain size. A layer was grown at 0.2 cm/sec in the experimental coater which was partially dendritic but also contained a large smooth area approximately 100 micron m thick. The dark characteristic measurements of a typical SCC solar cell yield shunt resistance values of 10K ohms and series resistance values and 0.4 ohm. The production dip-coater is operating at over 50 percent yield in terms of good cell quality material. The most recent run yielded 13 good substrates out of 15.

  5. Removal of nitrate and sulphate from biologically treated municipal wastewater by electrocoagulation

    NASA Astrophysics Data System (ADS)

    Sharma, Arun Kumar; Chopra, A. K.

    2017-06-01

    The present investigation observed the effect of current density ( j), electrocoagulation (EC) time, inter electrode distance, electrode area, initial pH and settling time on the removal of nitrate (NO3 -) and sulphate (SO4 2-) from biologically treated municipal wastewater (BTMW), and optimization of the operating conditions of the EC process. A glass chamber of two-liter volume was used for the experiments with DC power supply using two electrode plates of aluminum (Al-Al). The maximum removal of NO3 - (63.21 %) and SO4 2- (79.98 %) of BTMW was found with the optimum operating conditions: current density: 2.65 A/m2, EC time: 40 min, inter electrode distance: 0.5 cm, electrode area: 160 cm2, initial pH: 7.5 and settling time: 60 min. The EC brought down the concentration of NO3 - within desirable limit of the Bureau of Indian Standard (BIS)/WHO for drinking water. Under optimal operating conditions, the operating cost was found to be 1.01/m3 of water in terms of the electrode consumption (23.71 × 10-5 kg Al/m3) and energy consumption (101.76 kWh/m3).

  6. Evaluation of factors affecting soil carbon sequestration services of stormwater wet retention ponds in varying climate zones.

    PubMed

    Merriman, L S; Moore, T L C; Wang, J W; Osmond, D L; Al-Rubaei, A M; Smolek, A P; Blecken, G T; Viklander, M; Hunt, W F

    2017-04-01

    The carbon sequestration services of stormwater wet retention ponds were investigated in four different climates: U.S., Northern Sweden, Southern Sweden, and Singapore, representing a range of annual mean temperatures, growing season lengths and rainfall depths: geographic factors that were not statistically compared, but have great effect on carbon (C) accumulation. A chronosequence was used to estimate C accumulations rates; C accumulation and decomposition rates were not directly measured. C accumulated significantly over time in vegetated shallow water areas (0-30cm) in the USA (78.4gCm -2 yr -1 ), in vegetated temporary inundation zones in Sweden (75.8gCm -2 yr -1 ), and in all ponds in Singapore (135gCm -2 yr -1 ). Vegetative production appeared to exert a stronger influence on relative C accumulation rates than decomposition. Comparing among the four climatic zones, the effects of increasing rainfall and growing season lengths (vegetative production) outweighed the effects of higher temperature on decomposition rates. Littoral vegetation was a significant source to the soil C pool relative to C sources draining from watersheds. Establishment of vegetation in the shallow water zones of retention ponds is vital to providing a C source to the soil. Thus, the width of littoral shelves containing this vegetation along the perimeter may be increased if C sequestration is a design goal. This assessment establishes that stormwater wet retention ponds can sequester C across different climate zones with generally annual rainfall and lengths of growing season being important general factors for C accumulation. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. 11.72-sq cm Active-Area Wafer Interconnected PiN Diode Pulsed at 64 kA Dissipates 382 J and Exhibits an Action of 1.7 MA(sup 2)-s

    DTIC Science & Technology

    2012-01-30

    calculated action exceeded 1.7 MA2 -s. Preliminary efforts on high voltage diode interconnection have produced quarter wafer interconnected PiN...was packaged in a “hockey-puck” configuration and pulsed to 64 kA, dissipating 382 J with a calculated action exceeding 1.7 MA2 -s. II. FULL...epitaxial layers are utilized. 11.72-cm2 Active-area Wafer Interconnected PiN Diode pulsed at 64 kA dissipates 382 J and exhibits an action of 1.7 MA2 -s

  8. Preventive effect of chemical peeling on ultraviolet induced skin tumor formation.

    PubMed

    Abdel-Daim, Mohamed; Funasaka, Yoko; Kamo, Tsuneyoshi; Ooe, Masahiko; Matsunaka, Hiroshi; Yanagita, Emmy; Itoh, Tomoo; Nishigori, Chikako

    2010-10-01

    Chemical peeling is one of the dermatological treatments available for certain cutaneous diseases and conditions or improvement of cosmetic appearance of photoaged skin. We assessed the photochemopreventive effect of several clinically used chemical peeling agents on the ultraviolet (UV)-irradiated skin of hairless mice. Chemical peeling was done using 35% glycolic acid dissolved in distilled water, 30% salicylic acid in ethanol, 10% or 35% trichloroacetic acid (TCA) in distilled water at the right back of UV-irradiated hairless mice every 2 weeks in case of glycolic acid, salicylic acid, and 10% TCA and every 4 weeks in case of 35% TCA for totally 18 weeks after the establishment of photoaged mice by irradiation with UVA+B range light three times a week for 10 weeks at a total dose of 420 J/cm(2) at UVA and 9.6 J/cm(2) at UVB. Tumor formation was assessed every week. Skin specimens were taken from treated and non-treated area for evaluation under microscopy, evaluation of P53 expression, and mRNA expression of cyclooxygenase (COX)-2. Serum level of prostaglandin E(2) was also evaluated. All types of chemical peeling reduced tumor formation in treated mice, mostly in the treated area but also non-treated area. Peeling suppressed clonal retention of p53 positive abnormal cells and reduced mRNA expression of COX-2 in treated skin. Further, serum prostaglandin E(2) level was decreased in chemical peeling treated mice. These results indicate that chemical peeling with glycolic acid, salicylic acid, and TCA could serve tumor prevention by removing photodamaged cells. Copyright © 2010 Japanese Society for Investigative Dermatology. Published by Elsevier Ireland Ltd. All rights reserved.

  9. Effects of Dietary Fructose Restriction on Liver Fat, De Novo Lipogenesis, and Insulin Kinetics in Children With Obesity.

    PubMed

    Schwarz, Jean-Marc; Noworolski, Susan M; Erkin-Cakmak, Ayca; Korn, Natalie J; Wen, Michael J; Tai, Viva W; Jones, Grace M; Palii, Sergiu P; Velasco-Alin, Moises; Pan, Karen; Patterson, Bruce W; Gugliucci, Alejandro; Lustig, Robert H; Mulligan, Kathleen

    2017-09-01

    Consumption of sugar is associated with obesity, type 2 diabetes mellitus, nonalcoholic fatty liver disease, and cardiovascular disease. The conversion of fructose to fat in liver (de novo lipogenesis [DNL]) may be a modifiable pathogenetic pathway. We determined the effect of 9 days of isocaloric fructose restriction on DNL, liver fat, visceral fat (VAT), subcutaneous fat, and insulin kinetics in obese Latino and African American children with habitual high sugar consumption (fructose intake >50 g/d). Children (9-18 years old; n = 41) had all meals provided for 9 days with the same energy and macronutrient composition as their standard diet, but with starch substituted for sugar, yielding a final fructose content of 4% of total kilocalories. Metabolic assessments were performed before and after fructose restriction. Liver fat, VAT, and subcutaneous fat were determined by magnetic resonance spectroscopy and imaging. The fractional DNL area under the curve value was measured using stable isotope tracers and gas chromatography/mass spectrometry. Insulin kinetics were calculated from oral glucose tolerance tests. Paired analyses compared change from day 0 to day 10 within each child. Compared with baseline, on day 10, liver fat decreased from a median of 7.2% (interquartile range [IQR], 2.5%-14.8%) to 3.8% (IQR, 1.7%-15.5%) (P < .001) and VAT decreased from 123 cm 3 (IQR, 85-145 cm 3 ) to 110 cm 3 (IQR, 84-134 cm 3 ) (P < .001). The DNL area under the curve decreased from 68% (IQR, 46%-83%) to 26% (IQR, 16%-37%) (P < .001). Insulin kinetics improved (P < .001). These changes occurred irrespective of baseline liver fat. Short-term (9 days) isocaloric fructose restriction decreased liver fat, VAT, and DNL, and improved insulin kinetics in children with obesity. These findings support efforts to reduce sugar consumption. ClinicalTrials.gov Number: NCT01200043. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  10. 808-nm laser therapy with a flat-top handpiece photobiomodulates mitochondria activities of Paramecium primaurelia (Protozoa).

    PubMed

    Amaroli, Andrea; Ravera, Silvia; Parker, Steven; Panfoli, Isabella; Benedicenti, Alberico; Benedicenti, Stefano

    2016-05-01

    Photobiomodulation is proposed as a non-linear process, and only low-level laser therapy (LLLT) is assumed to stimulate exposed cells, whereas high powered laser and fluences can cause negative effects, exhausting the cell's energy reserve as a consequence of excessive photon-based stimulation. In our work, we investigated and compared the effects of 808-nm diode laser (CW) with a new flat-top handpiece. To this purpose, we tested the photobiomodulation effects of 1 and 3 J/cm(2) fluence, both generated by 100 mW or 1 W of laser power and of 64 J/cm(2) of fluence generated by 100 mW, 1 W, 1.5 W or 2 W, as expressed through oxygen consumption and ATP synthesis of Paramecium. Data collected indicates the incremental consumption of oxygen through irradiation with 3 J/cm(2)-100 mW or 64 J/cm(2)-1 W correlates with an increase in Paramecium ATP synthesis. The Paramecium respiration was inhibited by fluences 64 J/cm(2)-100 mW or 64 J/cm(2)-2 W and was followed by a decrease in the endogenous ATP concentration. The 1 J/cm(2)-100 mW or 1 W and 3 J/cm(2)-1 W did not affect mitochondrial activity. The results show that the fluence of 64 J/cm(2)-1 W more than the 3 J/cm(2)-100 mW causes greater efficiency in Paramecium mitochondria respiratory chain activity. Our results suggest that thanks to flat-top handpiece we used, high fluences by high-powered laser have to be reconsidered as an effective and non-invasive therapy. Possible associated benefits of deeper tissue penetration would increase treatment effectiveness and reduced irradiation time.

  11. Mosquito density, biting rate and cage size effects on repellent tests.

    PubMed

    Barnard, D R; Posey, K H; Smith, D; Schreck, C E

    1998-01-01

    Mosquito biting rates and the mean duration of protection (in hours) from bites (MDPB) of Aedes aegypti and Anopheles quadrimaculatus, using the repellent 'deet' (N,N-diethyl-3-methylbenzamide) on a 50 cm2 area of healthy human skin, were observed in small (27 l), medium (approximately 65 l) and large (125 l) cages containing low, medium or high densities of mosquitoes: respectively, 640, 128 or 49 cm3 of cage volume per female. At the initial treatment rate of approximately 0.4 microliter/cm2 (1 ml of 25% deet in ethanol on 650 cm2 of skin), the MDPB for deet against Ae. aegypti ranged from 4.5 to 6.5 h and was significantly less (5.0 +/- 0.8 h) in large cages compared with medium (6.2 +/- 0.9 h) and small (6.2 +/- 0.8 h) cages, regardless of the density. Against An. quadrimaculatus the MDPB for deet 0.4 microliter/cm2 was 1.5-8.0 h, less in small (3.7 +/- 2.3 h) and large (2.2 +/- 1.1 h) cages at medium (3.7 +/- 2.3 h) and high (2.5 +/- 1.7 h) mosquito densities, and was longest in medium cages (6.2 +/- 2.6 h) at low mosquito densities (5.8 +/- 2.8 h). With equinoxial photoperiodicity (light on 06.00-18.00 hours) the biting rate was influenced by the time of observation (08.00, 12.00, 16.00 hours) for Ae. aegypti but not for An. quadrimaculatus. For both species, the biting rate was inversely proportional to mosquito density and the MDPB. The shortest MDPBs were obtained in large cages with high densities of mosquitoes and longest protection times occurred in medium sized cages with low mosquito densities.

  12. Radiation exposure in transcatheter patent ductus arteriosus closure: time to tune?

    PubMed

    Villemain, Olivier; Malekzadeh-Milani, Sophie; Sitefane, Fidelio; Mostefa-Kara, Meriem; Boudjemline, Younes

    2018-05-01

    The aims of this study were to describe radiation level at our institution during transcatheter patent ductus arteriosus occlusion and to evaluate the components contributing to radiation exposure. Transcatheter occlusion relying on X-ray imaging has become the treatment of choice for patients with patent ductus arteriosus. Interventionists now work hard to minimise radiation exposure in order to reduce risk of induced cancers. We retrospectively reviewed all consecutive children who underwent transcatheter closure of patent ductus arteriosus from January 2012 to January 2016. Clinical data, anatomical characteristics, and catheterisation procedure parameters were reported. Radiation doses were analysed for the following variables: total air kerma, mGy; dose area product, Gy.cm2; dose area product per body weight, Gy.cm2/kg; and total fluoroscopic time. A total of 324 patients were included (median age=1.51 [Q1-Q3: 0.62-4.23] years; weight=10.3 [6.7-17.0] kg). In all, 322/324 (99.4%) procedures were successful. The median radiation doses were as follows: total air kerma: 26 (14.5-49.3) mGy; dose area product: 1.01 (0.56-2.24) Gy.cm2; dose area product/kg: 0.106 (0.061-0.185) Gy.cm2/kg; and fluoroscopic time: 2.8 (2-4) min. In multivariate analysis, a weight >10 kg, a ductus arteriosus width <2 mm, complications during the procedure, and a high frame rate (15 frames/second) were risk factors for an increased exposure. Lower doses of radiation can be achieved with subsequent recommendations: technical improvement, frame rate reduction, avoidance of biplane cineangiograms, use of stored fluoroscopy as much as possible, and limitation of fluoroscopic time. A greater use of echocardiography might even lessen the exposure.

  13. THE EFFECT OF TEMPERATURE AND UNIAXIAL PRESSURE ON THE DENSIFICATION BEHAVIOR OF SILICA AEROGEL GRANULES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matyas, Josef; Robinson, Matthew J.; Fryxell, Glen E.

    Materials are being developed in U.S. for the removal and immobilization of iodine from gaseous products of nuclear fuel reprocessing in support of the Fuel Cycle Technology Separations and Waste Forms Campaign. The silver-functionalized silica aerogel proved to be an excellent candidate for this treatment because of its high selectivity and sorption capacity for radioiodine and its possible conversion to a durable silica-based waste form. The present study investigated with nitrogen sorption and helium pycnometry the effect of pressureless isothermal sintering at temperatures of 900-1400°C for 2.5-90 min or isothermal hot-pressing at 1200°C for 2.5 min on densification of rawmore » and silver-functionalized silica aerogel granules. Rapid sintering was observed at 1050 and 1200°C. Only 15 min of pressureless sintering at 1200°C resulted in almost complete densification. The macropores disappeared, surface area decreased from 1114 m2/g to 25 m2/g, pore volume from 7.41 cm3/g to 0.09 cm3/g, and adsorption pore size from 18.7 to 7 nm. The skeletal density of sintered granules was similar to the bulk density of amorphous silica (2.2 g/cm3). The hot-pressing accelerated the sintering process, decreasing significantly the pore size and volume.« less

  14. Achondroplasia in children: correlation of ventriculomegaly, size of foramen magnum and jugular foramina, and emissary vein enlargement.

    PubMed

    Bosemani, Thangamadhan; Orman, Gunes; Hergan, Benedikt; Carson, Kathryn A; Huisman, Thierry A G M; Poretti, Andrea

    2015-01-01

    Achondroplasia is a skeletal dysplasia with diminished growth of the skull base secondary to defective enchondral bone formation. This leads to narrowing of the foramen magnum and jugular foramina, which further leads to ventricular dilatation and prominence of the emissary veins. The primary goal of our study was to determine a correlation between the degree of ventricular dilatation, jugular foramina and foramen magnum narrowing, as well as emissary vein enlargement. Conventional T2-weighted MR images were evaluated for surface area of the foramen magnum and jugular foramina, ventricular dilatation, and emissary veins enlargement in 16 achondroplasia patients and 16 age-matched controls. Ratios were calculated for the individual parameters using median values from age-matched control groups to avoid age as a confounder. Compared to age-matched controls, in children with achondroplasia, the surface area of the foramen magnum (median 0.50 cm(2), range 0.23-1.37 cm(2) vs. 3.14 cm(2), 1.83-6.68 cm(2), p < 0.001) and jugular foramina (median 0.02 cm(2), range 0-0.10 cm(2) vs. 0.21 cm(2), 0.03-0.61 cm(2), p < 0.001) were smaller, whereas ventricular dilatation (0.28, 0.24-0.4 vs. 0.26, 0.21-0.28, p < 0.001) and enlargement of emissary veins (6, 0-11 vs. 0, p < 0.001) were higher. Amongst the patients, Spearman correlation and multiple regression analysis did not reveal correlation for severity between the individual parameters. Our study suggests that in children with achondroplasia, (1) the variation in ventricular dilatation may be related to an unquantifiable interdependent relationship of emissary vein enlargement, venous channel narrowing, and foramen magnum compression and (2) stable ventricular size facilitated by interdependent factors likely obviates the need for ventricular shunt placement.

  15. Aortic Cross-Sectional Area/Height Ratio and Outcomes in Patients With a Trileaflet Aortic Valve and a Dilated Aorta.

    PubMed

    Masri, Ahmad; Kalahasti, Vidyasagar; Svensson, Lars G; Roselli, Eric E; Johnston, Douglas; Hammer, Donald; Schoenhagen, Paul; Griffin, Brian P; Desai, Milind Y

    2016-11-29

    In patients with a dilated proximal ascending aorta and trileaflet aortic valve, we aimed to assess (1) factors independently associated with increased long-term mortality and (2) the incremental prognostic utility of indexing aortic root to patient height. We studied consecutive patients with a dilated aortic root (≥4 cm) that underwent echocardiography and gated contrast-enhanced thoracic aortic computed tomography or magnetic resonance angiography between 2003 and 2007. A ratio of aortic root area over height was calculated (cm 2 /m) on tomography, and a cutoff of 10 cm 2 /m was chosen as abnormal, on the basis of previous reports. All-cause death was recorded. The cohort comprised 771 patients (63 years [interquartile range, 53-71], 87% men, 85% hypertension, 51% hyperlipidemia, 56% smokers). Inherited aortopathies, moderate to severe aortic regurgitation, and severe aortic stenosis were seen in 7%, 18%, and 2%, whereas 91% and 54% were on β-blockers and angiotensin-converting enzyme inhibitors, respectively. Aortic root area/height ratio was ≥10 cm 2 /m in 24%. The Society of Thoracic Surgeons score and right ventricular systolic pressure were 3.3±3 and 31±7 mm Hg, respectively. At 7.8 years (interquartile range, 6.6-8.9), 280 (36%) patients underwent aortic surgery (76% within 1 year) and 130 (17%) died (1% in-hospital postoperative mortality). A lower proportion of patients in the surgical (versus nonsurgical) group died (13% versus 19%, P<0.01). On multivariable Cox proportional hazard analysis, aortic root area/height ratio (hazard ratio, 4.04; 95% confidence interval [CI], 2.69-6.231) was associated with death, whereas aortic surgery (hazard ratio, 0.47; 95% CI, 0.27-0.81) was associated with improved survival (both P<0.01). For longer-term mortality, the addition of aortic root area/height ratio ≥10 cm 2 /m to a clinical model (Society of Thoracic Surgeons score, inherited aortopathies, hypertension, hyperlipidemia, medications, aortic regurgitation, and right ventricular systolic pressure), increased the c-statistic from 0.57 (95% CI, 0.35-0.77) to 0.65 (95% CI, 0.52-0.73) and net reclassification index from 0.17 (95% CI, 0.02-0.31) to 0.23 (95% CI, 0.04-0.34), both P<0.01. Of the 327 patients with aortic root diameter between 4.5 and 5.5 cm, 44% had an abnormal aortic root area/height ratio, of which 78% died. In patients with dilated aortic root and trileaflet aortic valve, a ratio of aortic root area to height provides independent and improved stratification for prediction of death. © 2016 American Heart Association, Inc.

  16. Large Area CVD MoS2 RF transistors with GHz performance

    NASA Astrophysics Data System (ADS)

    Nagavalli Yogeesh, Maruthi; Sanne, Atresh; Park, Saungeun; Akinwade, Deji; Banerjee, Sanjay

    Molybdenum disulfide (MoS2) is a 2D semiconductor in the family of transition metal dichalcogenides (TMDs). Its single layer direct bandgap of 1.8 eV allows for high ION/IOFF metal-oxide semiconducting field-effect transistors (FETs). More relevant for radio frequency (RF) wireless applications, theoretical studies predict MoS2 to have saturation velocities, vsat >3×106 cm/s. Facilitated by cm-scale CVD MoS2, here we design and fabricate both top-gated and embedded gate short channel MoS2 RF transistors, and provide a systematic comparison of channel length scaling, extrinsic doping from oxygen-deficient dielectrics, and a gate-first gate-last process flow. The intrinsic fT (fmax) obtained from the embedded gate transistors shows 3X (2X) improvement over top-gated CVD MoS2 RF FETs, and the largest high-field saturation velocity, vsat = 1.88 ×106 cm/s, in MoS2 reported so far. The gate-first approach, offers enhancement mode operation, ION/IOFF ratio of 10, 8< and the highest reported transconductance (gm) of 70 μS/ μm. By manipulating the interfacial oxygen vacancies in atomic layer deposited (ALD) HfO2-x we are able to achieve 2X current density over stoichiometric Al2O3. We demonstrate a common-source (CS) amplifier with voltage gain of 14 dB and an active frequency mixer with conversion gain of -15 dB. Our results of gigahertz frequency performance as well as analog circuit operation show that large area CVD MoS2 may be suitable for industrial-scale electronic applications.

  17. Tube Law of the Pharyngeal Airway in Sleeping Patients with Obstructive Sleep Apnea.

    PubMed

    Genta, Pedro R; Edwards, Bradley A; Sands, Scott A; Owens, Robert L; Butler, James P; Loring, Stephen H; White, David P; Wellman, Andrew

    2016-02-01

    Obstructive sleep apnea (OSA) is characterized by repetitive pharyngeal collapse during sleep. However, the dynamics of pharyngeal narrowing and re-expansion during flow-limited breathing are not well described. The static pharyngeal tube law (end-expiratory area versus luminal pressure) has demonstrated increasing pharyngeal compliance as luminal pressure decreases, indicating that the airway would be sucked closed with sufficient inspiratory effort. On the contrary, the airway is rarely sucked closed during inspiratory flow limitation, suggesting that the airway is getting stiffer. Therefore, we hypothesized that during inspiratory flow limitation, as opposed to static conditions, the pharynx becomes stiffer as luminal pressure decreases. Upper airway endoscopy and simultaneous measurements of airflow and epiglottic pressure were performed during natural nonrapid eye movement sleep. Continuous positive (or negative) airway pressure was used to induce flow limitation. Flow-limited breaths were selected for airway cross-sectional area measurements. Relative airway area was quantified as a percentage of end-expiratory area. Inspiratory airway radial compliance was calculated at each quintile of epiglottic pressure versus airway area plot (tube law). Eighteen subjects (14 males) with OSA (apnea-hypopnea index = 57 ± 27 events/h), aged 49 ± 8 y, with a body mass index of 35 ± 6 kg/m(2) were studied. A total of 163 flow limited breaths were analyzed (9 ± 3 breaths per subject). Compliances at the fourth (2.0 ± 4.7 % area/cmH2O) and fifth (0.0 ± 1.7 % area/cmH2O) quintiles were significantly lower than the first (12.2 ± 5.5 % area/cmH2O) pressure quintile (P < 0.05). The pharyngeal tube law is concave (airway gets stiffer as luminal pressure decreases) during respiratory cycles under inspiratory flow limitation. © 2016 Associated Professional Sleep Societies, LLC.

  18. Computed Tomography Measurement of Rib Cage Morphometry in Emphysema

    PubMed Central

    Sverzellati, Nicola; Colombi, Davide; Randi, Giorgia; Pavarani, Antonio; Silva, Mario; Walsh, Simon L.; Pistolesi, Massimo; Alfieri, Veronica; Chetta, Alfredo; Vaccarezza, Mauro; Vitale, Marco; Pastorino, Ugo

    2013-01-01

    Background Factors determining the shape of the human rib cage are not completely understood. We aimed to quantify the contribution of anthropometric and COPD-related changes to rib cage variability in adult cigarette smokers. Methods Rib cage diameters and areas (calculated from the inner surface of the rib cage) in 816 smokers with or without COPD, were evaluated at three anatomical levels using computed tomography (CT). CTs were analyzed with software, which allows quantification of total emphysema (emphysema%). The relationship between rib cage measurements and anthropometric factors, lung function indices, and %emphysema were tested using linear regression models. Results A model that included gender, age, BMI, emphysema%, forced expiratory volume in one second (FEV1)%, and forced vital capacity (FVC)% fit best with the rib cage measurements (R2 = 64% for the rib cage area variation at the lower anatomical level). Gender had the biggest impact on rib cage diameter and area (105.3 cm2; 95% CI: 111.7 to 98.8 for male lower area). Emphysema% was responsible for an increase in size of upper and middle CT areas (up to 5.4 cm2; 95% CI: 3.0 to 7.8 for an emphysema increase of 5%). Lower rib cage areas decreased as FVC% decreased (5.1 cm2; 95% CI: 2.5 to 7.6 for 10 percentage points of FVC variation). Conclusions This study demonstrates that simple CT measurements can predict rib cage morphometric variability and also highlight relationships between rib cage morphometry and emphysema. PMID:23935872

  19. Prolonged swimming performance of northern squawfish

    USGS Publications Warehouse

    Mesa, Matthew G.; Olson, Todd M.

    1993-01-01

    We determined the prolonged swimming performance of two size-classes of northern squawfish Ptychocheilus oregonensis at 12 and 18°C. The percentage of fish fatigued was positively related to water velocity and best described by an exponential model. At 12°C, the velocity at which 50% of the fish fatigued (FV50) was estimated to be 2.91 fork lengths per second (FL/s; 100 cm/s) for medium-sized fish (30–39 cm) and 2.45 FL/s (104 cm/s) for large fish (40–49 cm). At 18°C, estimated FV50 was 3.12 FL/s (107 cm/s) for medium fish and 2.65 FL/s (112 cm/s) for large fish. Rate of change in percent fatigue was affected by fish size and water temperature. Large fish fatigued at a higher rate than medium-sized fish; all fish fatigued faster at 12 than at 18°C. The mean times to fatigue at velocities of 102–115 cm/s ranged from 14 to 28 min and were not affected by fish size or water temperature. Our results indicate that water velocities from 100 to 130 cm/s may exclude or reduce predation by northern squawfish around juvenile salmonid bypass outfalls at Columbia River dams, at least during certain times of the year. We recommend that construction or modification of juvenile salmonid bypass facilities place the outfall in an area of high water velocity and distant from eddies, submerged cover, and littoral areas.

  20. Cortical inhibition and excitation by bilateral transcranial alternating current stimulation.

    PubMed

    Cancelli, Andrea; Cottone, Carlo; Zito, Giancarlo; Di Giorgio, Marina; Pasqualetti, Patrizio; Tecchio, Franca

    2015-01-01

    Transcranial electric stimulations (tES) with amplitude-modulated currents are promising tools to enhance neuromodulation effects. It is essential to select the correct cortical targets and inhibitory/excitatory protocols to reverse changes in specific networks. We aimed at assessing the dependence of cortical excitability changes on the current amplitude of 20 Hz transcranial alternating current stimulation (tACS) over the bilateral primary motor cortex. We chose two amplitude ranges of the stimulations, around 25 μA/cm2 and 63 μA/cm2 from peak to peak, with three values (at steps of about 2.5%) around each, to generate, respectively, inhibitory and excitatory effects of the primary motor cortex. We checked such changes online through transcranial magnetic stimulation (TMS)-induced motor evoked potentials (MEPs). Cortical excitability changes depended upon current density (p = 0.001). Low current densities decreased MEP amplitudes (inhibition) while high current densities increased them (excitation). tACS targeting bilateral homologous cortical areas can induce online inhibition or excitation as a function of the current density.

  1. Annual reduction of solar UV exposure to the facial area of outdoor workers in Southeast Queensland by wearing a hat.

    PubMed

    Wong, J C; Airey, D K; Fleming, R A

    1996-06-01

    The total annual exposure to erythemally effective UVR was estimated for average work situations in a high exposure environment, viz, farm workers in Southeast Queensland (27.5 degrees S), and the effect of hat usage was examined. If no sun protection is used, the annual erythema exposures for this group of workers at three facial sites forehead, nose and cheek are 40, 57 and 34 J.cm-2 respectively. If a hat is worn throughout the year, the exposures are reduced to 6, 19 and 20 J.cm-2, respectively. The mean ratio of exposure without the hat to that with the hat (mean protection factor, MPF) was found to be 6 for the forehead, 3 for the nose and 2 for the cheek. The risk of non-melanoma skin cancers without the protection of the hat is estimated to increase by up to 100 times for basal cell carcinomas and 13 times for squamous cell carcinomas for a whole year of exposure.

  2. All-solution-processed PbS quantum dot solar modules

    NASA Astrophysics Data System (ADS)

    Jang, Jihoon; Shim, Hyung Cheoul; Ju, Yeonkyeong; Song, Jung Hoon; An, Hyejin; Yu, Jong-Su; Kwak, Sun-Woo; Lee, Taik-Min; Kim, Inyoung; Jeong, Sohee

    2015-05-01

    A rapid increase in power conversion efficiencies in colloidal quantum dot (QD) solar cells has been achieved recently with lead sulphide (PbS) QDs by adapting a heterojunction architecture, which consists of small-area devices associated with a vacuum-deposited buffer layer with metal electrodes. The preparation of QD solar modules by low-cost solution processes is required to further increase the power-to-cost ratio. Herein we demonstrate all-solution-processed flexible PbS QD solar modules with a layer-by-layer architecture comprising polyethylene terephthalate (PET) substrate/indium tin oxide (ITO)/titanium oxide (TiO2)/PbS QD/poly(3-hexylthiophene) (P3HT)/poly(3,4-ethylenedioxythiophene) : poly(styrene sulfonate) (PEDOT : PSS)/Ag, with an active area of up to 30 cm2, exhibiting a power conversion efficiency (PCE) of 1.3% under AM 1.5 conditions (PCE of 2.2% for a 1 cm2 unit cell). Our approach affords trade-offs between power and the active area of the photovoltaic devices, which results in a low-cost power source, and which is scalable to larger areas.A rapid increase in power conversion efficiencies in colloidal quantum dot (QD) solar cells has been achieved recently with lead sulphide (PbS) QDs by adapting a heterojunction architecture, which consists of small-area devices associated with a vacuum-deposited buffer layer with metal electrodes. The preparation of QD solar modules by low-cost solution processes is required to further increase the power-to-cost ratio. Herein we demonstrate all-solution-processed flexible PbS QD solar modules with a layer-by-layer architecture comprising polyethylene terephthalate (PET) substrate/indium tin oxide (ITO)/titanium oxide (TiO2)/PbS QD/poly(3-hexylthiophene) (P3HT)/poly(3,4-ethylenedioxythiophene) : poly(styrene sulfonate) (PEDOT : PSS)/Ag, with an active area of up to 30 cm2, exhibiting a power conversion efficiency (PCE) of 1.3% under AM 1.5 conditions (PCE of 2.2% for a 1 cm2 unit cell). Our approach affords trade-offs between power and the active area of the photovoltaic devices, which results in a low-cost power source, and which is scalable to larger areas. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr01508a

  3. New Treatment Applying Low Level Laser Therapy for Acute Dehiscence Saphenectomy in Post Myocardial Revascularization.

    NASA Astrophysics Data System (ADS)

    Pinto, Nathali Cordeiro; Shoji, Nara; Junior, Mauro Favoretto; Muramatso, Mikiya; Chavantes, Maria Cristina; Stolf, Noedir A. G.

    2008-04-01

    Introduction: In Brazil, the main cause of death is the coronary heart disease and the surgical treatment applied in such cases is the Myocardial Revascularization (MR). Patients undergoing to MR through saphenous vein bypass development dehiscence in 10% of the cases. Dehiscence of surgical incision through Biomodulation treatment with Low Level Laser Therapy (LLLT) in patients who underwent to MR seems to be an unprecedented new therapy and a less invasive technique, which can benefit patients and Institutions, reducing costs. Methodology: It was analyzed 7 diabetic patients, mean age 51, 8 years old that post MR surgery presented dehiscence of the saphenectomy incision on lower limb with erithema, edema and pain. The wounds area varies from 2,2 until 34,8 cm and deep from 0,1 until 1,1 cm. It was used only Diode Laser C.W. (655 nm wavelength), Power = 25 mW, Time = 30 s, Fluence = 4 J/cm2 applied punctually around surgical wound's sore, by 2 cm distance. Results: It was observed granulated tissue all around the incision, as well as decreased inflammatory process, reduction fibrin and wound's size, besides analgesic effect since the first application. It was required in superficial wounds only 3 applications, while in the extensive wounds 8-10 applications were necessary. The LLLT has shown a remarkable role as a wound healing facilitated agent, reflecting the reduction of inflammatory process and improving analgesia. Conclusion: LLLT assisted dehiscence post saphenectomy showed a substantial improvement to the patient's quality of life, with a cost-effectiveness treatment that can benefit both patients and Institutions as an effective and less invasive therapy.

  4. Calculation of Lung Cancer Volume of Target Based on Thorax Computed Tomography Images using Active Contour Segmentation Method for Treatment Planning System

    NASA Astrophysics Data System (ADS)

    Patra Yosandha, Fiet; Adi, Kusworo; Edi Widodo, Catur

    2017-06-01

    In this research, calculation process of the lung cancer volume of target based on computed tomography (CT) thorax images was done. Volume of the target calculation was done in purpose to treatment planning system in radiotherapy. The calculation of the target volume consists of gross tumor volume (GTV), clinical target volume (CTV), planning target volume (PTV) and organs at risk (OAR). The calculation of the target volume was done by adding the target area on each slices and then multiply the result with the slice thickness. Calculations of area using of digital image processing techniques with active contour segmentation method. This segmentation for contouring to obtain the target volume. The calculation of volume produced on each of the targets is 577.2 cm3 for GTV, 769.9 cm3 for CTV, 877.8 cm3 for PTV, 618.7 cm3 for OAR 1, 1,162 cm3 for OAR 2 right, and 1,597 cm3 for OAR 2 left. These values indicate that the image processing techniques developed can be implemented to calculate the lung cancer target volume based on CT thorax images. This research expected to help doctors and medical physicists in determining and contouring the target volume quickly and precisely.

  5. Risk of inundation to coastal wetlands and soil organic carbon and organic nitrogen accounting in Louisiana, USA.

    PubMed

    Zhong, Biao; Xu, Y Jun

    2011-10-01

    Exceeding 1.2 million acres (4856 km(2)) since the 1930s, coastal wetland loss has been the most threatening environmental problem in Louisiana, United States. This study utilized high-resolution LiDAR (Light Detection and Ranging) and DEM (Digital Elevation Model) data sets to assess the risk of potential wetland loss due to future sea level rises, their spatial distribution, and the associated loss of soil organic carbon (SOC) and organic nitrogen (SON) estimated from the State Soil Geographic (STATSGO) Database and National Wetlands Inventory (NWI) digital data. Potential inundation areas were divided into five elevation scales: < 0 cm, 0-50 cm, 50-100 cm, 100-150 cm, and 150-200 cm above mean sea level. The study found that southeastern Louisiana on the Mississippi River Delta, specifically the Pontchartrain and Barataria Basins, are most vulnerable to sea-level rise induced inundation. Accordingly, approximately 42,264,600 t of SOC and 2,817,640 t of SON would be inundated by 2050 using an average wetland SOC density (203 t per hectare) for the inundation areas between 0 and 50 cm. The estimated annual SOC and SON loss from Louisiana's coast is 17% of annual organic carbon and 6-8% of annual organic nitrogen inputs from the Mississippi River.

  6. Use of a Sampling Area-Adjusted Adenosine Triphosphate Bioluminescence Assay Based on Digital Image Quantification to Assess the Cleanliness of Hospital Surfaces.

    PubMed

    Ho, Yu-Huai; Wang, Lih-Shinn; Jiang, Hui-Li; Chang, Chih-Hui; Hsieh, Chia-Jung; Chang, Dan-Chi; Tu, Hsin-Yu; Chiu, Tan-Yun; Chao, Huei-Jen; Tseng, Chun-Chieh

    2016-06-09

    Contaminated surfaces play an important role in the transmission of pathogens. We sought to establish a criterion that could indicate "cleanliness" using a sampling area-adjusted adenosine triphosphate (ATP) assay. In the first phase of the study, target surfaces were selected for swab sampling before and after daily cleaning; then, an aerobic colony count (ACC) plate assay of bacteria and antibiotic-resistant bacteria was conducted. ATP swabs were also tested, and the ATP readings were reported as relative light units (RLUs). The results of the ACC and ATP assays were adjusted according to the sampling area. During the second phase of the study, a new cleaning process employing sodium dichloroisocyanurate (NaDCC) was implemented for comparison. Using the criterion of 2.5 colony-forming units (CFU)/cm², 45% of the sampled sites were successfully cleaned during phase one of the study. During phase two, the pass rates of the surface samples (64%) were significantly improved, except under stringent (5 RLU/cm²) and lax (500 RLU) ATP criteria. Using receiver-operating characteristic curve analysis, the best cut-off point for an area-adjusted ATP level was 7.34 RLU/cm², which corresponded to culture-assay levels of <2.5 CFU/cm². An area adjustment of the ATP assay improved the degree of correlation with the ACC-assay results from weak to moderate.

  7. Broadband light trapping strategies for quantum-dot photovoltaic cells (>10%) and their issues with the measurement of photovoltaic characteristics.

    PubMed

    Cho, Changsoon; Song, Jung Hoon; Kim, Changjo; Jeong, Sohee; Lee, Jung-Yong

    2017-12-12

    Bandgap tunability and broadband absorption make quantum-dot (QD) photovoltaic cells (PVs) a promising candidate for future solar energy conversion systems. Approaches to improving the electrical properties of the active layer increase efficiency in part. The present study focuses on optical room for enhancement in QD PVs over wide spectrum in the near-infrared (NIR) region. We find that ray-optical light trapping schemes rather than the nanophotonics approach may be the best solution for enhancing broadband QD PVs by suppressing the escape probability of internal photons without spectral dependency. Based on the theoretical study of diverse schemes for various bandgaps, we apply a V-groove structure and a V-groove textured compound parabolic trapper (VCPT) to PbS-based QD PVs along with the measurement issues for PVs with a light scattering layer. The efficiency of the best device is improved from 10.3% to 11.0% (certified to 10.8%) by a V-groove structure despite the possibility of underestimation caused by light scattering in small-area devices (aperture area: 0.0625 cm 2 ). By minimizing such underestimation, even greater enhancements of 13.6% and 15.6% in short circuit current are demonstrated for finger-type devices (0.167 cm 2 without aperture) and large-area devices (2.10 cm 2 with an aperture of 0.350 cm 2 ), respectively, using VCPT.

  8. Plastic-Film Mulching for Enhanced Water-Use Efficiency and Economic Returns from Maize Fields in Semiarid China.

    PubMed

    Zhang, Peng; Wei, Ting; Cai, Tie; Ali, Shahzad; Han, Qingfang; Ren, Xiaolong; Jia, Zhikuan

    2017-01-01

    Film mulch has gradually been popularized to increase water availability to crops for improving and stabilizing agricultural production in the semiarid areas of Northwest China. To find more sustainable and economic film mulch methods for alleviating drought stress in semiarid region, it is necessary to test optimum planting methods in same cultivation conditions. A field experiment was conducted during 2013 and 2014 to evaluate the effects of different plastic film mulch methods on soil water, soil temperature, water use efficiency (WUE), yield and revenue. The treatments included: (i) the control, conventional flat planting without plastic film mulch (CK); (ii) flat planting with maize rows (60 cm spacing) on plastic film mulch (70 cm wide); (iii) furrow planting of maize (60 cm spacing), separated by consecutive plastic film-mulched ridges (each 50 cm wide and 15 cm tall); (iv) furrow planting of maize (60 cm spacing), separated by alternating large and small plastic film-mulched ridges (large ridges: 70 cm wide and 15 cm tall, small ridges 50 cm wide and 10 cm tall); and (v) furrow-flat planting of maize (60 cm spacing) with a large plastic film-mulched ridge (60 cm wide and 15 cm tall) alternating with a flat without plastic film-mulched space (60 cm wide). Topsoil temperature (5-25 cm) was significantly ( p < 0.05) higher in field plots with plastic film mulch than the control (CK), and resulted in greater soil water storage (0-200 cm) up to 40 days after planting. Maize grain yield and WUE were significantly ( p < 0.05) higher with the furrow planting methods (consecutive film-mulched ridges and alternating film-mulched ridges) than the check in both years. Maize yield was, on average, 29% ( p < 0.05) greater and 28% ( p < 0.05) greater with these furrow planting methods, while the average WUE increased by 22.8% ( p < 0.05) with consecutive film-mulched ridges and 21.1% ( p < 0.05) with alternating film-mulched ridges. The 2-year average net income increased by 1559, 528, and 350 Chinese Yuan (CNY) ha -1 with the consecutive film-mulched ridges, furrow-flat planting and alternating film-mulched ridges, respectively, compared with the control (CK). We conclude that the consecutive film-mulched ridge method was the most productive and profitable for maize in this semi-arid area with limited and erratic precipitation.

  9. Climate change and Sea level rise: Potential impact on the coast of the Edremit Plain, NW Turkey.

    NASA Astrophysics Data System (ADS)

    Curebal, Isa; Efe, Recep; Soykan, Abdullah; Sonmez, Suleyman

    2015-04-01

    Over the past century, most of the world's mountain glaciers and the ice sheets have lost mass due to global warming. When the temperature exceeds a particular level, glaciers and polar ice caps will continue to lose mass. Recent studies report that low-lying coastal areas will be seriously affected by sea level rise. Changes in the amount of natural and anthropogenic greenhouse gases and aerosols had a warming effect on the global climate during last century. Thus, the pace of melting of ice sheets increased, and, accordingly, sea level began to rise faster. Rise in sea level between 1961 and 2003 was equal to 1.8 mm/year while it was 3.1 mm/year between 1993 and 2003. The total rise in the 20th century is estimated to be between 17 and 19 cm. The models based on the sea level change indicate that the average global temperature at the end of the 21st century will increase by 0.3°C - 6.4°C. Global sea level is projected to rise 8-25 cm by 2030, relative to 2000 levels, 18-48 cm by 2050, and 50-140 cm by 20110. The Edremit Plain lies between Mount Madra and the Kaz Mountains on the coast of Aegean Sea in NW Turkey. It is lowland with an area of 141 km2. The widest part of the plain is 16 km along the E - W direction. The N - S direction amounts to a width of 15 km. The plain is covered with alluvial deposits that settled in the Quaternary Period. The elevation ranges from 0 to 50 m a.s.l. in the plain. This study aims to determine how the low-lying coastal land areas of the Edremit Plain may be affected by possible changes in sea level. Elevation dataset is based on the digital elevation model (DEM) of Landsat ETM + satellite images. To that end, satellite images were used to draw the current coastline. Curves of 2.5, 5, and 10 m were drawn through the use of maps with a scale of 1/25.000. Later on, the areas of the fields between these points were calculated. Current estimates show that 2.5 m rise in sea level will cause sea water to cover an area of 8.6 km2 (%14.0), 5 m to 28.4 km2 (%21.2), and 10 m to 58.3 km2 (%41.2) on the coastal land. In such cases, a +2.5 m change will trigger the current coastline to regress by 1.3 km while a +5 m change will lead to 3.4 km, and a +10 m change will cause 5.2 km. As a result, residential, agricultural, and wetlands on the coastal land of the plain will be submerged by rising sea levels, leading to significant habitat loss and changes in the ecosystem. The creation of detailed elevation may reveal more clear effects of the changes in sea level. Key Words: Climate change, coastline, Edremit plain, global warming, sea level rise.

  10. Wound healing efficacy of a 660-nm diode laser in a rat incisional wound model.

    PubMed

    Suzuki, Ryoichi; Takakuda, Kazuo

    2016-11-01

    This study aimed to elucidate the optimum usage parameters of low reactive-level laser therapy (LLLT) in a rat incisional wound model. In Sprague-Dawley rats, surgical wounds of 15-mm length were made in the dorsal thoracic region. They were divided into groups to receive 660-nm diode laser irradiation 24 h after surgery at an energy density of 0 (control), 1, 5, or 10 J/cm 2 . Tissue sections collected on postoperative day 3 were stained with hematoxylin-eosin and an antibody for ED1 to determine the number of macrophages around the wound. Samples collected on day 7 were stained with hematoxylin-eosin and observed via polarized light microscopy to measure the area occupied by collagen fibers around the wound; day 7 skin specimens were also subjected to mechanical testing to evaluate tensile strength. On postoperative day 3, the numbers of macrophages around the wound were significantly lower in the groups receiving 1 and 5 J/cm 2 irradiation, compared to the control and 10 J/cm 2 irradiation groups (p < 0.01). The area occupied by collagen fibers in day 7 was largest in 5 J/cm 2 group, followed by 1 J/cm 2 group, although this difference was not significant. The day 7 tensile test demonstrated significantly greater rupture strength in healing tissues from 1 and 5 J/cm 2 irradiation groups, compared to the control group (p < 0.05). Thus, LLLT with a 660-nm diode laser with energy density of 1 and 5 J/cm 2 enhanced wound healing in a rat incisional wound model. However, a higher radiation energy density yielded no significant enhancement.

  11. Termites as a factor of spatial differentiation of CO2 fluxes from the soils of monsoon tropical forests in southern Vietnam

    NASA Astrophysics Data System (ADS)

    Lopes de Gerenyu, V. O.; Anichkin, A. E.; Avilov, V. K.; Kuznetsov, A. N.; Kurganova, I. N.

    2015-02-01

    Annual dynamics of CO2 fluxes from soils and the impact of the living activity of termites on them were studied in plain lagerstroemia semideciduous monsoon tropical forests of southern Vietnam. On the plot populated by Globitermes sulphureus and Odontotermes termites, a detailed study of the spatial heterogeneity of the CO2 emission from the surface of soil and termite mounds was performed in the wet and dry seasons. It was found that the average rate of the CO2 emission from termite mounds was two times and more higher than that from the background soil surface. In the dry season, it comprised 91 ± 7 mg C/m2 per h from the background soil and 196 ± 16 mg C/m2 per h from the termite mounds. In the wet season, the CO2 emission rate was considerably higher and reached 266 ± 40 and 520 ± 39 mg C/m2 per h, respectively. The maximum rates of CO2 fluxes were determined in the wet season in some of the measurement chambers installed on termite mounds; they reached 730-880 mg C/m2 per h. Though termite mounds occupy about 4% of the area of tropical forest ecosystems, the overall effect of termites on the carbon budget was more significant; according to our estimates, it reached up to 10% of the total efflux of CO2 from the soil surface.

  12. CROSS-DISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Effects of concentration and annealing on the performance of regioregular poly(3-hexylthiophene) field-effect transistors

    NASA Astrophysics Data System (ADS)

    Tian, Xue-Yan; Xu, Zheng; Zhao, Su-Ling; Zhang, Fu-Jun; Yuan, Guang-Cai; Xu, Xu-Rong

    2009-08-01

    This paper investigates the effects of concentration on the crystalline structure, the morphology, and the charge carrier mobility of regioregular poly(3-hexylthiophene) (RR-P3HT) field-effect transistors (FETs). The RR-P3HT FETs with RR-P3HT as an active layer with different concentrations of RR-P3HT solution from 0.5 wt% to 2 wt% are prepared. The results indicate that the performance of RR-P3HT FETs improves drastically with the increase of RR-P3HT weight percentages in chloroform solution due to the formation of more microcrystalline lamellae and bigger nanoscale islands. It finds that the field-effect mobility of RR-P3HT FET with 2 wt% can reach 5.78 × 10-3 cm2/Vs which is higher by a factor of 13 than that with 0.5 wt%. Further, an appropriate thermal annealing is adopted to improve the performance of RR-P3HT FETs. The field-effect mobility of RR-P3HT FETs increases drastically to 0.09 cm2/Vs by thermal annealing at 150 °C, and the value of on/off current ratio can reach 104.

  13. Effect of different management systems on soil CO2 emission and plant growth in a maize field

    NASA Astrophysics Data System (ADS)

    Dencso, Marton; Gelybó, Györgyi; Kása, Ilona; Pokovai, Klára; Potyó, Imre; Horel, Ágota; Birkás, Márta; Takács, Tünde; Tóth, Eszter

    2017-04-01

    In this study soil CO2 emission was examined in a long-term tillage experiment along with observations of plant morphological parameters, arbuscular mycorrhizal fungal (AMF) root colonization, soil properties and soil hydrothermal regime on loamy clay soil (Józsefmajor, Hungary) sown with maize. The tillage experiment was set up in 2002 and we focused on measurements performed in 2016. Based on soil disturbance depths, we selected three different tillage types such as ploughing (26-32 cm), shallow cultivation (12-16 cm), and no tillage (0 cm) for the present study. We examined CO2 emissions in rows compared to between rows within the same treatment in order to estimate the CO2 emission pattern in case of the different treatments. The measurements were carried out using the static chamber method in seven spatial replicates per treatment. For investigating plant morphological parameters of the maize we measured height of plants, leaf number and area, girth area of stem...etc. The CO2 data showed that the difference between ploughing and no tillage treatments was higher in the vegetation period of 2016 than during the dormant season. There were higher CO2 emissions in case of chambers inserted in rows than between rows on average, moreover there were significant differences between certain chambers installed in rows and between rows according to statistical data. This phenomenom can be explained by the enhanced root repiration in the rows. Based on plant morphology measurements we observed that plant developement was slower in no tillage treatment than in ploughing. Depending on sampling date, height of plants data showed 1.1 to 1.5 higher values, while leaf area data showed 1.2 to 2.5 times higher areas in case of ploughing compared to no tillage treatment. This can be due to the different soil conditions and textures of the treatments. The AMF root colonization data showed minor differences between ploughing and no tillage treatments, the highest colonization rates were found in case of shallow cultivation.

  14. 46 CFR 148.300 - Radioactive materials.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Radioactive materials. 148.300 Section 148.300 Shipping... MATERIALS THAT REQUIRE SPECIAL HANDLING Special Requirements for Certain Materials § 148.300 Radioactive... surface, when averaged over an area of 300 cm2, does not exceed the following levels: (1) 4.0 Bq/cm2 (10−4...

  15. The effect of the KTP laser on smear layer and temperature change: an in vitro study.

    PubMed

    Arslan, Dilara; Kuştarcı, Alper

    2018-01-01

    The purpose of this study was to evaluate the effects of potassium-titanyl-phosphate (KTP) laser irradiation on smear layer removal and temperature changes of the root surfaces. Two hundred four extracted single-root human premolars were included. The canals were instrumented and divided into two main groups: group A (smear layer examination n:119) and group B (temperature change examination n:85). Each group was divided into subgroups (n:17) according to the different five laser power settings: A1, B1: 1 W-5.33 J/cm 2 ; A2, B2: 1.5 W-7.52 J/cm 2 ; A3, B3: 2 W-10.3 J/cm 2 ; A4, B4: 3 W-15.5 J/cm 2 , A5, B5: 4 W-20.1 J/cm2, A6: positive control no laser irradiation-irrigated 2 mL for 2 min 2.5% NaOCl + 2 mL distilled water and A7: negative control groups no laser irradiation irrigated 2 mL for 2 min 17% EDTA + 2 mL for 2 min 2.5% NaOCl + 2 mL distilled water. The temperature elevations were measured with an infrared thermographic camera and smear layer examined by scanning electron microscope. According to Kruskal-Wallis and Tukey's tests, in all groups the highest smear scores were in the apical third. In all areas, there were statistically significant differences between negative control group (17% EDTA) and all other groups (p < 0.05). The highest smear scores were determined in 1 W KTP laser and positive control (2.5% NaOCl) groups. Statistically, in all thirds, the differences the 3 W and 4 W KTP laser groups between each other and all other groups were significant (p < 0.05). After the end of the use of the laser, increase in temperature values in all groups were found to be below 10 °C in 20 s.

  16. External and intralesional photocoagulation of hemangioma in children with infrared diode laser

    NASA Astrophysics Data System (ADS)

    Abushkin, Ivan A.; Privalov, Valery A.; Lappa, Alexander V.; Besshtanko, Evgeny L.

    2005-08-01

    Infra-red diode laser with wavelength 1060 nm was used for combined treatment of 163 children aged from 21 days to 13 years with 221 hemangiomas. For interstitial coagulation a power of 1.8-2 W and a power density of 5-90 J/cm3 were used in continuous mode. For distant coagulation pulse mode was applied with pulse/pause duration 30-50/200-250 ms, average power 1.3-2 W, and power density 65-450 J/cm2. 197 (89.1 %) hemangiomas were capillary, 7 (3.2 %) cavernous, and 17 (7.7 %) combined (combination of capillary and cavernous hemangiomas). The area of hemangiomas ranged from 6 mm2 to 48 cm2. For the majority (193, 87.3 %) of hemangiomas one session of photocoagulation was enough to achieve a good cosmetic effect. However, 28 (12.7 %) hemangiomas were treated repeatedly, 11 (5%) of them needed 4-7 sessions. In 8 children with cavernous and combined hemangiomas both distant and interstitial laser coagulation were used. In all, good or excellent results were obtained in 96,3 % of the patients. In 6 (3.7%) patients with extensive combined hematomas the considerable improvement was achieved.

  17. Effect of Carbon and Binder on High Sulfur Loading Electrode for Li-S Battery Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Ke; Cama, Christina A.; Huang, Jian

    For the Lithium-Sulfur (Li-S) battery to be competitive in commercialization, it is requested that the sulfur electrode must have deliverable areal capacity > 8 mAh cm -2, which corresponds to a sulfur loading > 6 mg cm -2. At this relatively high sulfur loading, we evaluated the impact of binder and carbon type on the mechanical integrity and the electrochemical properties of sulfur electrodes. We identified hydroxypropyl cellulose (HPC) as a new binder for the sulfur electrode because it offers better adhesion between the electrode and the aluminum current collector than the commonly used polyvinylidene fluoride (PVDF) binder. In combinationmore » with the binder study, multiple types of carbon with high specific surface area were evaluated as sulfur hosts for high loading sulfur electrodes. A commercial microporous carbon derived from wood with high pore volume showed the best performance. An electrode with sulfur loading up to 10 mg cm -2 was achieved with the optimized recipe. Based on systematic electrochemical studies, the soluble polysulfide to insoluble Li 2S 2/Li 2S conversion was identified to be the major barrier for high loading sulfur electrodes to achieve high sulfur utilization.« less

  18. Effect of Carbon and Binder on High Sulfur Loading Electrode for Li-S Battery Technology

    DOE PAGES

    Sun, Ke; Cama, Christina A.; Huang, Jian; ...

    2017-03-10

    For the Lithium-Sulfur (Li-S) battery to be competitive in commercialization, it is requested that the sulfur electrode must have deliverable areal capacity > 8 mAh cm -2, which corresponds to a sulfur loading > 6 mg cm -2. At this relatively high sulfur loading, we evaluated the impact of binder and carbon type on the mechanical integrity and the electrochemical properties of sulfur electrodes. We identified hydroxypropyl cellulose (HPC) as a new binder for the sulfur electrode because it offers better adhesion between the electrode and the aluminum current collector than the commonly used polyvinylidene fluoride (PVDF) binder. In combinationmore » with the binder study, multiple types of carbon with high specific surface area were evaluated as sulfur hosts for high loading sulfur electrodes. A commercial microporous carbon derived from wood with high pore volume showed the best performance. An electrode with sulfur loading up to 10 mg cm -2 was achieved with the optimized recipe. Based on systematic electrochemical studies, the soluble polysulfide to insoluble Li 2S 2/Li 2S conversion was identified to be the major barrier for high loading sulfur electrodes to achieve high sulfur utilization.« less

  19. Monitoring for PCBs at the Pilot Plant Complex, Aberdeen Proving Ground

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, J.F.; O`Neill, H.J.; Cohut, V.J.

    1995-07-01

    The US Army`s Aberdeen Proving Ground has been a test site for a variety of munitions, including chemical warfare agents. The Pilot Plant Complex (PPC) at Aberdeen was the site of the development, manufacture, storage, and disposal of a number of chemical warfare agents. The objective of this study was to determine if there is polychlorinated biphenyl (PCB) contamination in the PPC. The results of screening done by Argonne indicate that PCBs in the air of the PPC are well below acceptable levels. The total PCB burden of the surfaces in the PPC appears to be well below the 50-ppMmore » regulatory level. However, the study identified contaminated floor surfaces that exceed the acceptable level of 10 {mu}g/100 cm{sup 2} for a workplace. Areas in Building E5618 exceed 1,000 {mu}g/100 cm{sup 2}, with a high reading of 21,100 {mu}g/100 cm{sup 2} in room C103. Building E5625 has several areas where PCBs exceed 100 {mu}g/cm{sup 2}.« less

  20. Efficacy, tolerability, and safety of a long-pulsed ruby laser system in the removal of unwanted hair.

    PubMed

    Polderman, M C; Pavel, S; le Cessie, S; Grevelink, J M; van Leeuwen, R L

    2000-03-01

    Unwanted hair growth is a common, usually physiologic phenomenon. In this study the efficacy and tolerability of a long-pulsed ruby laser system was compared with needle electrolysis and hot wax on three parts of the body. Thirty volunteers were treated three times on the forearm (n = 10), on the face (n = 10), or in the pubic area (n = 10) with 25 J/cm2 laser, 40 J/cm2 laser, needle electrolysis, and hot wax therapy. The 25 J/cm2 and 40 J/cm2 laser treated sites showed a statistically significant decrease (38% and 49%, respectively) in the number of hairs at the first visit after the last treatment compared to the pretreatment hair counts. No significant decrease was observed in the needle electrolysis and hot wax treated sites. Laser therapy yielded better results on the forearm than on the face or pubic area and was scored as the least painful. The long-pulsed ruby laser is a promising, well-tolerated method of epilation.

  1. [Habitat suitability index model and minimum habitat area estimation of young Procypris rabaudi (Tchang): a simulation experiment in laboratory].

    PubMed

    Feng, Xian-Bin; Zhu, Yong-Jiu; Li, Xi; He, Yong-Feng; Zhao, Jian-Hua; Yang, De-Guo

    2013-01-01

    Under the conditions of simulated micro-habitat in laboratory, and by using experimental ecological methods, this paper evaluated the suitability index (HSI) of young Procypris rabaudi for habitat factors (substrate, light intensity and water depth). The habitat suitability models of the young P. rabaudi were established, and the minimum habitat area of the young P. rabaudi was estimated. The young P. rabaudi preferred the habitats with the gravel diameter from 10 to 15 cm, light intensity from 0.2 to 1.8 lx, and water depth from 0 to 15 cm (distance from the bottom of the tank). The three suitability index models of the substrate, light intensity and water depth for the young P. rabaudi were SI(s) = 1.7338e(-0.997x)(SI(S) is the suitability index of substrate, and x is the gravel diameter; R2 = 0.89, P < 0.01), SI(L) = 3.0121e(-1.339x)(SI(L) is the suitability index of light intensity, and x is the light intensity; R2 = 0.93, P < 0.01), and SI(W) = 2.4055e(-1.245x)(SI(W) is the suitability index of water depth, and x is the water depth; R2 = 0.97, P < 0.01), respectively. Arithmetic mean model HSI = (SI(S)+SI(L)+SI(W))/3 was most available for the estimation of the habitat suitability of young P. rabaudi. A total of seven groups of young P. rabaudi which established and maintained a relatively stable habitat area range were found. This habitat area ranged from 628 to 2015 cm2, with an average of 1114 cm2.

  2. Quantification of the internal resistance distribution of microbial fuel cells.

    PubMed

    Fan, Yanzhen; Sharbrough, Evan; Liu, Hong

    2008-11-01

    Identifying the limiting factors in a microbial fuel cell (MFC) system requires qualifying the contribution of each component of an MFC to internal resistance. In this study, a new method was developed to calculate the internal resistance distribution of an MFC. Experiments were conducted to identify the limiting factors in single-chamber MFCs by varying the anode surface areas, cathode surface areas, and phosphate buffer concentrations. For the MFCs with equally sized electrodes (7 cm2) and 200 mM phosphate buffer, the anode contributed just 5.4% of the internal resistance, while the cathode and the electrolyte each contributed 47.3%, indicating that the anode was not the limiting factor in power generation. The limitation of the cathode was further revealed by the 780% higher area-specific resistance (284.4 omega cm2) than the 32.3 omega cm2 of the anode. The electrolyte limitation was also evidenced by the greatly increased contribution of electrolyte in internal resistance from 47.3 to 78.2% when the concentration of phosphate buffer was decreased from 200 to 50 mM. An anodic power density of 6860 mW/m2 was achieved at a current density of 2.62 mA/cm2 using the MFCs with an anode/cathode area ratio of 1/14 and 200 mM phosphate buffer. The method was also successfully applied to analyze the internal resistance distribution of the two chamber MFCs from a previously reported study. The comparison of the internal resistances of the two air cathode systems indicates that the much lower resistances, including anode, cathode, and membrane resistances, contributed to the much better performance of the single-chamber MFCs than the two-chamber system.

  3. Comparative effect of beclomethasone dipropionate and cetirizine on acoustic rhinometry parameters in children with perennial allergic rhinitis: a randomized controlled trial.

    PubMed

    Malizia, V; Fasola, S; Ferrante, G; Cilluffo, G; Gagliardo, R; Landi, M; Montalbano, L; Marchese, D; La Grutta, S

    2018-04-24

    The effect of intranasal corticosteroids and oral antihistamines on acoustic rhinometry parameters was not directly compared in previous studies. Objectives: The primary aim was to compare the effect of 21-day treatment with nasal beclomethasone dipropionate (nBDP) versus cetirizine (CTZ) on nasal patency measured by acoustic rhinometry in children with PAR. Comparing their effect on nasal cytology, symptom severity, sleep quality and quality of life was the secondary aim. In this 21-day, open-label, randomized controlled study, 34 PAR children (6-14 years) with Total 5 Symptom Score (T5SS) ≥5 received nBDP 100 µg per nostril twice daily or CTZ 10 mg tablets once daily. Effect measures were the least square mean changes (LSmc) in nasal volume and Minimal Cross-sectional Area (MCA), nasal cytology, T5SS, Pittsburgh Sleep Quality Index (PSQI) and Paediatric Rhinoconjunctivitis Quality of Life Questionnaire (PRQLQ). After 21 days, nBDP improved nasal volume and MCA more than CTZ (LSmc 2.21 cm3 vs 0.20 cm3, p=0.013 and LSmc 0.63 cm2 vs 0.13 cm2, p=0.002, respectively). In the nBDP group, with respect to the CTZ group, larger improvement was found in: eosinophil (LSmc -1.10 vs -0.40, p=0.031) and neutrophil (LSmc -0.97 vs -0.17, p=0.010) classes, T5SS (LSmc -5.63 vs -3.54, p=0.008), PSQI (LSmc -1.30 vs -0.19, p=0.025) and PRQLQ total scores (LSmc -1.15 vs -0.69, p=0.031). In children with PAR, nBDP is more effective than CTZ in improving nasal patency measured by acoustic rhinometry, with associated beneficial effects on nasal cytology, symptoms, sleep quality and quality of life.

  4. Cutting efficiency of conventional and martensitic nickel-titanium instruments for coronal flaring.

    PubMed

    Morgental, Renata Dornelles; Vier-Pelisser, Fabiana Vieira; Kopper, Patrícia Maria Poli; de Figueiredo, José Antonio Poli; Peters, Ove A

    2013-12-01

    This study aimed at evaluating the influence of rotational speed and number of uses on the cutting efficiency of 4 nickel-titanium coronal flaring instruments against 2 substrates, bovine dentin and acrylic blocks. BioRaCe BR0, HyFlex CM1, ProFile OS#2, and ProTaper Sx were used in simulated lateral action against both substrates at 250 and 500 rpm up to 5 times, producing 5 notches in each block. Notch areas and lengths were measured under a stereomicroscope, and data were compared by using parametric tests (α = 0.05). Against both substrates, HyFlex CM1 and ProFile OS#2 were the most and the least cutting efficient instruments, respectively (P < .05). Against acrylic, area and length values at 500 rpm were significantly higher than those at 250 rpm for all brands. Against dentin, significant differences were detected between 250 and 500 rpm for HyFlex CM1 and ProTaper Sx (area) and for BioRace BR0, HyFlex CM1, and ProTaper Sx (length). Regarding cutting efficiency loss, area and length for notches 1 and 2 (first notches) and 4 and 5 (last notches) were similar against acrylic. Against dentin, length values for notches 1 and 2 were significantly higher than those for notches 4 and 5 in ProFile OS#2 and ProTaper Sx. A strong correlation was detected between the overall results obtained on acrylic and dentin for area and length (P < .0001), although further analysis showed that data against acrylic were a poor predictor of data against dentin after repeated use. HyFlex CM1 was the most cutting efficient instrument in lateral action. An increase in rotational speed improved the cutting efficiency. Results against acrylic showed a high correlation to data against dentin, but acrylic may not be a proper substrate when the intention is to assess cutting efficiency loss with repeated use. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Evaluation of bovine hemimandible morphology by means of elliptic Fourier descriptors.

    PubMed

    Parés-Casanova, Pere M

    2014-01-01

    The aim of this research was to compare size (area) and shape variations of bovine hemimandibles according to age. Digital photographs were obtained for 34 hemimandibles belonging to different European breeds of cattle. The specimens were classified according to age, as determined by molar eruption: b months ("young", M1 erupting, n = 8), 10 months ("immature", M2 erupting, n = 9) and over 24 months ("adult", M3 fully erupted, n = 17). Captured images were then digitally analysed based on elliptic Fourier descriptors, which mathematically characterise the area and shape. Hemimandibular areas only showed significant differences between the adults (2752.3 cm2 +/- 250.4) and young subjects (2373.8 cm2 +/- 300.2). The areas for each age group were not linked to linear shape modifications, which was the same for all age groups. So, bovine hemimandibular form change is mainly related to size changes. Shape variability is centred on the condylar ramus.

  6. Termites as a factor of spatial differentiation of CO2 fluxes from the soils of monsoon tropical forests in Southern Vietnam

    NASA Astrophysics Data System (ADS)

    Lopes de Gerenyu, Valentin; Anichkin, Alexander

    2016-04-01

    Termites play the key role in biogeochemical transformation of organic matter acting as "moderators" of fluxes of carbon and other nutrients. They destroy not only leave litter but also coarse woody debris. Termites translocate considerable masses of dead organic materials into their houses, which leads to significant accumulations of organic matter in termite mounds. We studied the impact of termite mounds on redistribution of CO2 fluxes from soils in semi-deciduous monsoon tropical forests of southern Vietnam. Field study was performed in the Cat Tien National Park (11°21'-11°48'N, 107°10'-107°34'E). The spatial and temporary dynamics of CO2 fluxes from soils (Andosols) populated by termites were studied in plain lagerstroemia (Lagerstroemia calyculata Kurz) monsoon tropical forests. The rate of CO2 emission from the soil surface was measured by closed chamber method two-three times per month from November 2010 to December 2011. Permanent cylindrical PVC chambers (9 cm in diameter and 15 cm in height) were installed beyond the areas occupied by termite mounds (5 replications). Litter was not removed from the soil surface before the measurements. To estimate the spatial heterogeneity of the CO2 emission fluxes from soils populated by termites, a special 'termite' plot (TerPl) was equipped. It was 10×10 m in size and included three termite mounds: one mound built up by Globitermes sulphureus and two mounds populated by termites of the Odontotermes genus. Overall, 52 PVC chambers were installed permanently on the 'termite' plot (ca. 1 m apart from one another). The CO2 emission rate from TerPl was also measured by chamber closed method once in the dry season (April) and twice through the wet season (July and August). The average rate of CO2 emission from termite mounds was two times higher than that from the surrounding area (SurAr). In the dry season, it comprised 91±7 mg C/m2/h from the surrounding soils and 196±16 mg C/m2/h from the termite mounds. In the wet season, the CO2 emission rate was considerably higher and reached 266±40 and 520 ± 39 mg C/m2/h in SurAr and TerPl, respectively. The highest rates of CO2 fluxes (730-880 mg C/m2/h) were observed in the wet season in some of the chambers installed on TerPl. In the tropical forest, termites are the factor of the significant spatial variability in the CO2 fluxes from the soils. On the plots populated by termites, the coefficient of variation of CO2 emission rates reached 79%, while it rarely exceeded 45% on the surrounding area. The termite mounds occupy about 4% of the area of tropical forest ecosystems. However, the overall effect of termites on the carbon budget was more significant and, according to our estimates, it reached up to 10% of the total annual CO2 flux from the soils. Thus, underestimation of the influence of termites may lead to significant errors in the assessment of the organic carbon budget in the semi-deciduous tropical forests.

  7. Development of a large-area planar surface-wave plasma source with a cavity launcher driven by a 915 MHz UHF wave

    NASA Astrophysics Data System (ADS)

    Chang, Xijiang; Kunii, Kazuki; Liang, Rongqing; Nagatsu, Masaaki

    2013-04-01

    A large-area planar surface-wave plasma (SWP) source driven by a 915 MHz ultrahigh frequency (UHF) wave was developed. To avoid using large, thick dielectric plates as vacuum windows, we propose a cavity launcher consisting of a cylindrical cavity with several small quartz discs at the bottom. Three types of launchers with quartz discs located at different positions were tested to compare their plasma production efficiencies and spatial distributions of electron density. With the optimum launcher, large-area plasma discharges with a radial uniformity within ±10% were obtained in a radius of about 25-30 cm in Ar gas at 8 Pa for incident power in the range 0.5-2.5 kW. The maximum electron density and temperature were approximately (0.95-1.1) × 1011 cm-3 and 1.9-2.0 eV, respectively, as measured by a Langmuir probe located 24 cm below the bottom of the cavity launcher. Using an Ar/NH3 SWP with the optimum launcher, we demonstrated large-area amino-group surface modification of polyurethane sheets. Experimental results indicated that a uniform amino-group modification was achieved over a radius of approximately 40 cm, which is slightly larger than the radial uniformity of the electron density distribution.

  8. Vertical distribution of 137Cs in grassland soils disturbed by moles (Talpa europaea L.).

    PubMed

    Ramzaev, V; Barkovsky, A

    2018-04-01

    Activity of biota is one of the factors influencing vertical migration of radionuclides deposited from the atmosphere onto the ground surface. The goal of this work was to study the vertical distribution of 137 Cs in grassland soils disturbed by moles (Talpa europaea L.) in comparison with undisturbed grassland soils. Field observations and soil sampling were carried out in the areas of eight settlements in the Klintsovskiy, Krasnogorskiy and Novozybkovskiy districts of the Bryansk region, Russia in six years during the period 1999-2016. The study sites had been heavily contaminated by Chernobyl fallout in 1986. Activity of 137 Cs in soil samples was determined by γ-ray spectrometry. 137 Cs surface ground contamination levels at the studied plots (n = 17) ranged from 327 kBq m -2 to 2360 kBq m -2 with a mean of 1000 kBq m -2 and a median of 700 kBq m -2 . The position of the 137 Cs migration centre in the soil in 2010-2016 was significantly (the Mann-Whitney U test, P < .01) deeper at mole-disturbed plots (median = 5.99 cm or 6.64 g cm -2 , n = 6) compared to the undisturbed ones (median = 2.48 cm or 2.35 g cm -2 , n = 6). The 137 Cs migration rate at mole-disturbed plots (median = 0.26 g cm -2  y -1 , mean = 0.31 g cm -2  y -1 ) was significantly higher (by a factor of 3) than at undisturbed plots (median = 0.08 g cm -2  y -1 , mean = 0.10 g cm -2  y -1 ). The difference in the migration rates between the mole-disturbed and undisturbed plots (median = 0.18 g cm -2  y -1 , mean = 0.21 g cm -2  y -1 ) reasonably corresponded to the mass of soil that might be ejected by moles per unit area per year. The results of this study indicate that the burrowing activity of moles has increased vertical migration of Chernobyl-derived radiocaesium in the grassland soils. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. [APPLICATION OF V-Y ADVANCED SENSE-REMAINED POSTERIOR TIBIAL ARTERY PERFORATOR FLAP IN REPAIRING WOUND AROUND ANKLE].

    PubMed

    Tang, Xiujun; Wang, Bo; Wei, Zairong; Wang, Dali; Han, Wenjie; Zhang, Wenduo; Li, Shujun

    2015-12-01

    OBJECTIVE To explore the feasibility and effectiveness of V-Y advanced sense-remained posterior tibial artery perforator flap in repairing wound around the ankle. METHODS Between March 2012 and January 2015, 11 patients with wounds around the ankle were treated by V-Y advanced sense-remained posterior tibial artery perforator flap. There were 6 males and 5 females with a median age of 37 years (range, 21-56 years). The causes were traffic accident injury in 3 cases, thermal injury in 2 cases, burn in 2 cases, iatrogenic wounds in 2 cases, and local contusion in 2 cases. The disease duration ranged from 1 to 3 weeks (mean, 2 weeks). Injury was located at the medial malleolus in 4 cases, at the lateral malleolus in 3 cases, and at the heel in 4 cases. All had exposure of bone, tendon, or plate. The defect area ranged from 4 cmx2 cm to 5 cmx3 cm; the area of the flap ranged from 11 cmx4 cm to 15 cmx6 cm. Necrosis of distal flap occurred in 1 case after operation; re-operation to amputate the posterior tibial artery was given and the wound was repaired by proximal skin graft. Light necrosis of distal end was observed in 2 cases, and wound healed at 3 weeks after dressing. And other flaps successfully survived, and primary healing of wounds were obtained. The patients were followed up 6-24 months (mean, 11 months). The flaps were good in color, texture, and appearance. The ankle joint had normal activity. At last follow-up, 10 cases restored fine sense, and 1 case restored protective feeling with posterior tibial artery advanced flap after amputation. V-Y advanced sense-remained posterior tibial artery perforator flap has the advantages of reliable blood supply, simple operation, good appearance, and sensory recovery. Therefore, it is an ideal method to repair wound around the ankle.

  10. Method of precisely modifying predetermined surface layers of a workpiece by cluster ion impact therewith

    DOEpatents

    Friedman, L.; Beuhler, R.J.; Matthew, M.W.; Ledbetter, M.

    1984-06-25

    A method of precisely modifying a selected area of a workpiece by producing a beam of charged cluster ions that is narrowly mass selected to a predetermined mean size of cluster ions within a range of 25 to 10/sup 6/ atoms per cluster ion, and accelerated in a beam to a critical velocity. The accelerated beam is used to impact a selected area of an outer surface of the workpiece at a preselected rate of impacts of cluster ions/cm/sup 2//sec in order to effect a precise modification in that selected area of the workpiece.

  11. Method of precisely modifying predetermined surface layers of a workpiece by cluster ion impact therewith

    DOEpatents

    Friedman, Lewis; Buehler, Robert J.; Matthew, Michael W.; Ledbetter, Myron

    1985-01-01

    A method of precisely modifying a selected area of a workpiece by producing a beam of charged cluster ions that is narrowly mass selected to a predetermined mean size of cluster ions within a range of 25 to 10.sup.6 atoms per cluster ion, and accelerated in a beam to a critical velocity. The accelerated beam is used to impact a selected area of an outer surface of the workpiece at a preselected rate of impacts of cluster ions/cm.sup.2 /sec. in order to effect a precise modification in that selected area of the workpiece.

  12. Bend-resistant large mode area fiber with novel segmented cladding

    NASA Astrophysics Data System (ADS)

    Ma, Shaoshuo; Ning, Tigang; Pei, Li; Li, Jing; Zheng, Jingjing

    2018-01-01

    A novel structure of segment cladding fiber (SCF) with characteristics of bend-resistance and large-mode-area (LMA) is proposed. In this new structure, the high refractive index (RI) core is periodically surrounded by high RI fan-segmented claddings. Numerical investigations show that effective single-mode operation of the proposed fiber with mode field area of 700 μm2 can be achieved when the bending radius is 15 cm. Besides, this fiber is insensitive to the bending orientation at the ranging of [-180°, 180°]. The proposed design shows great potential in high power fiber lasers and amplifiers with compact structure.

  13. Shallow Depth Study Using Gravity & Magnetics Data in Central Java - Yogyakarta

    NASA Astrophysics Data System (ADS)

    Fawzy Ismullah M, Muhammad; Altin Massinai, Muhammad; Maria

    2018-03-01

    Gravity and magnetics measurements carried out in Karangsambung - Bayat - Wonosari track, Central Java - Yogyakarta region as much as 34 points for subsurface identification. Modeling and interpretation using both data at 3 sections. Section A lies on Karangsambung area and reach to 1900 m. Section A showed formation of 0.000001 - 0.0014 nT and 2.00 - 2.80 g/cm3 like alluvium, basalt and tuff. Section B lies on Wates - Yogyakarta area and reach to 1700 m. Section B showed formation of (-0.01) - 0.02 nT and 2.40 - 3.00 g/cm3 like andesite intrusive and Merapi volcano sediments. Section C lies on Bayat - Wonosari area and reach to 2000 m. Section C showed formation of 0.00016 - 0.0005 nT and 2.30 - 3.14 g/cm3 like limestone, tuff and diorite intrusive. Based on modeling results from 2D structure inversion method can identify the formation of sediments from volcano activity on Karangsambung - Bayat - Wonosari track, Central Java - Yogyakarta region. The method of this study shows potential application for identify the formation of volcano activity from 2D structure.

  14. Wolter-Schwarzschild optics for the extreme-ultraviolet - The Berkeley stellar spectrometer and the EUV Explorer

    NASA Technical Reports Server (NTRS)

    Malina, R. F.; Bowyer, S.; Finley, D.; Cash, W.

    1979-01-01

    The design, fabrication and performance of two Wolter-Schwarzschild grazing incidence optics are described. Both telescopes have been figured by single point diamond turning and have achieved better than 15-arcsec on-axis imaging. The telescope for the stellar spectrometer is an f/10 Type II system with an effective area of 225 sq cm at 250 A and 300 cm2 at 500 A. The primary has a maximum diameter of 38 cm and was fabricated in three elements. The copper-plated aluminum substrate was diamond turned; following nickel plating, the surface was polished and coated with evaporated gold. The performance during a sounding rocket flight is discussed. The prototype telescope for the Extreme Ultraviolet Explorer is an f/1.24 Type I system with an effective field of view of 5.0-deg diameter. The telescope has a maximum diameter of 40 cm and was fabricated as a single element. The aluminum substrate is to be diamond turned; the nickel plated surface will be polished and electroplated with gold. The design choice and defocusing optimization aimed at maximizing the field of view and number of image pixels is examined.

  15. Sediment accumulation rates and high-resolution stratigraphy of recent fluvial suspension deposits in various fluvial settings, Morava River catchment area, Czech Republic

    NASA Astrophysics Data System (ADS)

    Sedláček, Jan; Bábek, Ondřej; Kielar, Ondřej

    2016-02-01

    We present a comprehensive study concerning sedimentary processes in fluvial sediment traps within the Morava River catchment area (Czech Republic) involving three dammed reservoirs, four meanders and oxbow lakes, and several natural floodplain sites. The objective of the study was to determine sediment accumulation rates (SAR), estimate erosion rates, calculating these using a combination of the 137Cs method and historical data. Another purpose of this study was to provide insight into changing erosion and accumulation rates over the last century. Extensive water course modifications were carried out in the Morava River catchment area during the twentieth century, which likely affected sedimentation rates along the river course. Other multiproxy stratigraphic methods (X-ray densitometry, magnetic susceptibility, and visible-light reflectance spectrometry) were applied to obtain additional information about sediment infill. Sediment stratigraphy revealed distinct distal-to-proximal patterns, especially in reservoirs. Granulometrically, silts and sandy silts prevailed in sediments. Oxbow lakes and meanders contained larger amounts of clay and organic matter, which is the main difference between them and reservoirs. Pronounced 137Cs peaks were recorded in all studied cores (maximum 377 Bq·kg- 1), thus indicating Chernobyl fallout from 1986 or older events. Calculated sediment accumulation rates were lowest in distal parts of reservoirs (0.13-0.58 cm/y) and floodplains (0.45-0.88 cm/y), moderately high rates were found in proximal parts of reservoirs and oxbow lakes (2.27-4.4 cm/y), and the highest rates in some oxbow lakes located near the river (6-8 cm/y). The frequency of the inundation still can be high in some natural areas as in the Litovelské Pomoraví protected area, whereas the decreasing frequency of the inundation in other modified parts can contribute to a lower sedimentation rate. The local effects such as difference between SARs in oxbow lakes and reservoirs, different grain size distribution in both systems, and high variability in thickness of their proximal and distal parts play a crucial role in the analysis of regional accumulation rates. Local effects are much stronger than regional effects, such as rainfall and land use. Combined with the low resolution of time scales (usually only three datums are available: reservoir construction datum, 137Cs fallout event, and top of sediment), these effects may obscure the general trends of regionally increasing or decreasing net SARs, making the analysis of erosion rates from the sedimentary record an extremely difficult task.

  16. Retrospective analysis of melasma treatment using a dual mode of low-fluence Q-switched and long-pulse Nd:YAG laser vs. low-fluence Q-switched Nd:YAG laser monotherapy.

    PubMed

    Choi, Chun Pil; Yim, Seon Mi; Seo, Soo Hong; Ahn, Hyo Hyun; Kye, Young Chul; Choi, Jae Eun

    2015-02-01

    Despite the effectiveness of low-fluence Q-switched Nd:YAG laser (QSNY) treatment in melasma, adverse events, including mottled hypopigmentation (MH) and rebound hyperpigmentation (RH) have been reported. To compare the effectiveness and safety of combination therapy using low-fluence QSNY and long-pulse Nd:YAG laser (LPNY) (Dual toning), with low-fluence QSNY monotherapy (QS toning), in Asian melasma patients. Patients were treated for 10 sessions at 1-week intervals with QSNY (6 mm spot); 2.5-3.0 J/cm(2) for QS toning (n = 177) or 2.1-2.5 J/cm(2) for dual toning (n = 183). The dual toning group was immediately treated with LPNY (7 mm spot, 15-17 J/cm(2)). The results were evaluated using the modified Melasma Area and Severity Index (mMASI) score and the physician's global assessment. MH or RH were significantly lower (1.1% vs. 14.1%) and the treatment efficacy was improved (median decrease of mMASI, 3.6 vs. 3.0) in the dual toning group compared with the QS toning group. Periorbital melasma showed distinctively high rates of adverse events in the QS toning group (23.9% vs. 5.7%), which were significantly reduced in the dual toning group (2.9%). Dual toning could represent a safe and effective treatment for Asian melasma patients, as it is associated with minimal adverse events and improved treatment efficacy compared with QS toning monotherapy.

  17. High Efficiency Large Area Polysilicon Solar Cells

    NASA Technical Reports Server (NTRS)

    Johnson, S. M.; Winter, C.

    1985-01-01

    Large area (100 sq cm) polysilicon solar cells having efficiencies of up to 14.1% (100 mW/sq cm, 25 C) were fabricated and a detailed analysis was performed to identify the efficiency loss mechanisms. The 1-5 characteristics of the best cell were dominated by recombination in the quasi-neutral base due to the combination of minority carrier diffusion length and base resistivity. An analysis of the microstructural defects present in the material and their effect on the electrical properties is presented.

  18. Large-area and highly crystalline MoSe2 for optical modulator

    NASA Astrophysics Data System (ADS)

    Yin, Jinde; Chen, Hao; Lu, Wei; Liu, Mengli; Li, Irene Ling; Zhang, Min; Zhang, Wenfei; Wang, Jinzhang; Xu, Zihan; Yan, Peiguang; Liu, Wenjun; Ruan, Shuangchen

    2017-12-01

    Transition metal dichalcogenides (TMDs) have been successfully used as broadband optical modulator materials for pulsed fiber laser systems. However, the nonlinear optical absorptions of exfoliated TMDs are strongly limited by their nanoflakes morphology with uncontrollable lateral size and thickness. In this work, we provide an effective method to fully explore the nonlinear optical properties of MoSe2. Large-area and high quality lattice MoSe2 grown by chemical vapor deposition method was adopted as an optical modulator for the first time. The large-area MoSe2 shows excellent nonlinear optical absorption with a large modulation depth of 21.7% and small saturable intensity of 9.4 MW cm-2. After incorporating the MoSe2 optical modulator into fiber laser cavity as a saturable absorber, a highly stable Q-switching operation with single pulse energy of 224 nJ is achieved. The large-area MoSe2 possessing superior nonlinear optical properties compared to exfoliated nanoflakes affords possibility for the larger-area two-dimensional materials family as high performance optical devices.

  19. Relationship between ventral hernia defect area and intra-abdominal pressure: dynamic in vivo measurement.

    PubMed

    Qandeel, Haitham; O'Dwyer, Patrick J

    2016-04-01

    It is an acceptable concept that the ventral hernia defect area will increase with a rise in intra-abdominal pressure (IAP). The literature lacks the evidence about how much this increase is in vivo. The aim of this study was to objectively measure the change in the ventral hernia defect area with increasing intra-abdominal pressure. In a prospective study of laparoscopic ventral hernia repair, the area of hernia defect was measured from inside the abdomen using a sterile paper ruler. The horizontal (width) and vertical (length) measurements of the defect were taken at two pressure points: (IAP = 8 mmHg) and (IAP = 15 mmHg). The hernia defect area was calculated as an oval shape using a standard formula. Eighteen consecutive patients with a ventral hernia were included in this study (8 males: 10 females). Median age was 60 years (30-81), body mass index (BMI) was 29.9 (22.6-37.6). Changing the IAP significantly, (P < 0.001) changed the values of horizontal and vertical measurements, and the calculated area of the ventral hernia defect. The median calculated defect area, as an oval shape, was 5.6 cm(2) (Q1-Q3 = 3.5-15.5) and 6.9 cm(2) (Q1-Q3 = 4.5-18.7) at 8 and 15 mmHg IAP, respectively. The calculated area of mesh required to cover the defect with a 5 cm overlap increased by a median of 5% (Q1-Q3 = 3-6%). The change in defect area did not differ significantly between obese and non-obese patients (P = 0.5). Dynamic, rather than static, measurements of ventral hernia area during laparoscopy provide a simple way of in vivo objective measurement that helps the surgeon choose the appropriate area of mesh. When choosing mesh area, we support the trend toward a larger overlap of at least 5 cm if less precise methods of measuring defect area are been used.

  20. An enhanced effective mode area fluorine doped octagonal photonic crystal fiber with extremely low loss

    NASA Astrophysics Data System (ADS)

    Kabir, Sumaiya; Razzak, S. M. Abdur

    2018-07-01

    In our paper an enhanced effective mode area octagonal photonic crystal fiber (PCF) is presented. This PCF ensures large effective mode area along with ultra-low confinement loss and bending loss. Both the elimination of air-holes from the rings near the core region and inclusion of low index fluorine doped silica rods in an octagonal pattern are the vital design features. We have used full vectorial finite element method (FEM) based software with circularly perfectly matched layer (PML) to simulate the guiding properties of PCF. Our proposed fiber achieves effective mode area of 1110 μm2. Moreover, it offers ultra-low confinement loss of 1.14 × 10-15 dB/m and can be bent as small as 30 cm without any significant bending loss of 6.49 × 10-9 dB/m. The PCF also ensures low non-linearity with small amount of splice loss. However, our proposed PCF can be used in applications like fiber amplifiers and lasers.

  1. Permeability predictions for sand-clogged Portland cement pervious concrete pavement systems.

    PubMed

    Haselbach, Liv M; Valavala, Srinivas; Montes, Felipe

    2006-10-01

    Pervious concrete is an alternative paving surface that can be used to reduce the nonpoint source pollution effects of stormwater runoff from paved surfaces such as roadways and parking lots by allowing some of the rainfall to permeate into the ground below. This infiltration rate may be adversely affected by clogging of the system, particularly clogging or covering by sand in coastal areas. A theoretical relation was developed between the effective permeability of a sand-clogged pervious concrete block, the permeability of sand, and the porosity of the unclogged block. Permeabilities were then measured for Portland cement pervious concrete systems fully covered with extra fine sand in a flume using simulated rainfalls. The experimental results correlated well with the theoretical calculated permeability of the pervious concrete system for pervious concrete systems fully covered on the surface with sand. Two different slopes (2% and 10%) were used. Rainfall rates were simulated for the combination of direct rainfall (passive runoff) and for additional stormwater runoff from adjacent areas (active runoff). A typical pervious concrete block will allow water to pass through at flow rates greater than 0.2 cm/s and a typical extra fine sand will have a permeability of approximately 0.02 cm/s. The limit of the system with complete sand coverage resulted in an effective system permeability of approximately 0.004 cm/s which is similar to the rainfall intensity of a 30 min duration, 100-year frequency event in the southeastern United States. The results obtained are important in designing and evaluating pervious concrete as a paving surface within watershed management systems for controlling the quantity of runoff.

  2. Baseline factors affecting closure of venous leg ulcers.

    PubMed

    Marston, William A; Ennis, William J; Lantis, John C; Kirsner, Robert S; Galiano, Robert D; Vanscheidt, Wolfgang; Eming, Sabine A; Malka, Marcin; Cargill, D Innes; Dickerson, Jaime E; Slade, Herbert B

    2017-11-01

    The objective of this study was to characterize factors associated with closure of venous leg ulcers (VLUs) in a pooled analysis of subjects from three randomized clinical trials. Closure of VLUs after treatment with HP802-247, an allogeneic living cell therapy consisting of growth-arrested human keratinocytes and fibroblasts, vs standard therapy with compression bandaging was evaluated in three phase 3 clinical trials of similar design. Two trials enrolled subjects with VLUs ranging from 2 cm 2 to 12 cm 2 in area with 12-week treatment periods; the third trial enrolled subjects with VLUs between >12 cm 2 and ≤36 cm 2 with a 16-week treatment period. The first trial went to completion but failed to demonstrate a benefit to therapy with HP802-247 compared with placebo, and because of this, the remaining trials were terminated before completion. On the basis of no differences in outcomes between groups, subjects from both HP802-247 and control groups were pooled across all three studies. Cox proportional hazards regression analysis was employed to evaluate factors associated with VLU closure. This analysis included data from 716 subjects with VLU. Factors evaluated for association with healing included age, gender, race, diabetes, glycated hemoglobin level, body mass index, treatment (HP802-247 vs compression alone), and ulcer characteristics including location and area and duration at baseline. In an initial model including all of these putative factors, the following were significant at the P < .10 level: diagnosis of diabetes mellitus, gender, wound location (ankle or leg), baseline wound area, and wound duration at baseline. In a final model including only these factors, all but diabetes mellitus were significant at the P < .05 level. Effect sizes were as follows (hazard ratio [95% confidence interval]): female gender (1.384 [1.134-1.690]), wound location on the leg (1.490 [1.187-1.871]), smaller wound area at baseline (0.907 [0.887-0.927]), and shorter wound duration at baseline (0.971 [0.955-0.987]). Factors associated with VLU lesions including location, area, and duration were important predictors of healing. Women were more likely than men to achieve wound closure. Factors including body mass index, the presence of diabetes mellitus, and higher concentrations of glycated hemoglobin were not significant independent predictors of wound closure in this analysis. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  3. Clinical utility of calf front hoof circumference and maternal intrapelvic area in predicting dystocia in 103 late gestation Holstein-Friesian heifers and cows.

    PubMed

    Hiew, Mark W H; Megahed, Ameer A; Townsend, Jonathan R; Singleton, Wayne L; Constable, Peter D

    2016-02-01

    The objective of this study was to determine the clinical utility of measuring calf front hoof circumference, maternal intrapelvic area, and selected morphometric values in predicting dystocia in dairy cattle. An observational study using a convenience sample of 103 late-gestation Holstein-Friesian heifers and cows was performed. Intrapelvic height and width of the dam were measured using a pelvimeter, and the intrapelvic area was calculated. Calf front hoof circumference and birth weight were also measured. Data were analyzed using Spearman's correlation coefficient (rs), Mann-Whitney U test, and binary or ordered logistic regression; P < 0.05 was significant. The calving difficulty score (1-5) was greater in heifers (median, 3.0) than in cows (median, 1.0). Median intrapelvic area immediately before parturition was smaller in heifers (268 cm(2)) than in cows (332 cm(2)), whereas front hoof circumference and birth weight of the calf were similar in both groups. The calving difficulty score was positively associated with calf birth weight in heifers (rs = 0.39) and cows (rs = 0.24). Binary logistic regression using both dam and calf data indicated that the ratio of front hoof circumference of the calf to the maternal intrapelvic area provided the best predictor of dystocia (calving difficulty score = 4 or 5), with sensitivity = 0.50 and specificity = 0.93 at the optimal cutpoint for the ratio (>0.068 cm/cm(2)). Determining the ratio of calf front hoof circumference to maternal intrapelvic area has clinical utility in predicting the calving difficulty score in Holstein-Friesian cattle. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Selectivity of Direct Methanol Fuel Cell Membranes.

    PubMed

    Aricò, Antonino S; Sebastian, David; Schuster, Michael; Bauer, Bernd; D'Urso, Claudia; Lufrano, Francesco; Baglio, Vincenzo

    2015-11-24

    Sulfonic acid-functionalized polymer electrolyte membranes alternative to Nafion(®) were developed. These were hydrocarbon systems, such as blend sulfonated polyetheretherketone (s-PEEK), new generation perfluorosulfonic acid (PFSA) systems, and composite zirconium phosphate-PFSA polymers. The membranes varied in terms of composition, equivalent weight, thickness, and filler and were investigated with regard to their methanol permeation characteristics and proton conductivity for application in direct methanol fuel cells. The behavior of the membrane electrode assemblies (MEA) was investigated in fuel cell with the aim to individuate a correlation between membrane characteristics and their performance in a direct methanol fuel cell (DMFC). The power density of the DMFC at 60 °C increased according to a square root-like function of the membrane selectivity. This was defined as the reciprocal of the product between area specific resistance and crossover. The power density achieved at 60 °C for the most promising s-PEEK-based membrane-electrode assembly (MEA) was higher than the benchmark Nafion(®) 115-based MEA (77 mW·cm(-2) vs. 64 mW·cm(-2)). This result was due to a lower methanol crossover (47 mA·cm(-2) equivalent current density for s-PEEK vs. 120 mA·cm(-2) for Nafion(®) 115 at 60 °C as recorded at OCV with 2 M methanol) and a suitable area specific resistance (0.15 Ohm cm² for s-PEEK vs. 0.22 Ohm cm² for Nafion(®) 115).

  5. Regional differences in the lateral mobility of plasma membrane lipids in a molluscan embryo.

    PubMed

    Speksnijder, J E; Dohmen, M R; Tertoolen, L G; de Laat, S W

    1985-07-01

    Regional and temporal differences in plasma membrane lipid mobility have been analyzed during the first three cleavage cycles of the embryo of the polar-lobe-forming mollusc Nassarius reticulatus by the fluorescence photobleaching recovery (FPR) method, using 1,1'-ditetradecyl 3,3,3',3'-tetramethylindocarbocyanine iodide (C14diI) as a fluorescent lipid probe. During this period of development the lateral diffusion coefficient of membrane lipids is consistently greater in the vegetal polar lobe area as compared to the animal plasma membrane area (on average 30%), demonstrating the existence of an animal-vegetal polarity in plasma membrane properties. At third cleavage, the differences between animal and vegetal plasma membrane region become even more pronounced; in the four animal micromeres the diffusion coefficient (D) and mobile fraction (MF) are 2.9 +/- 0.2 X 10(-9) cm2/sec and 51 +/- 2%, respectively, while in the four vegetal macromeres D = 5.0 +/- 0.3 X 10(-9) cm2/sec and MF = 78 +/- 2%. Superimposed upon the observed animal-vegetal polarity, the lateral diffusion in the polar lobe membrane area shows a cell-cycle-dependent modulation. The highest mean values for D are reached during the S phase (ranging from 7.0 to 7.8 X 10(-9) cm2/sec in the three cycles measured), while at the end of G2 phase and during early mitosis mean values for D have decreased significantly (ranging from 5.0 to 5.9 X 10(-9) cm2/sec). Diffusion rates in the animal membranes of the embryo are constant during the three successive cell cycles (D = 4.3-5.0 X 10(-9) cm2/sec), except for a peak at the S phase of the first cell cycle (D = 6.0 X 10(-9) cm2/sec). These results are discussed in relation with previously observed ultrastructural heterogeneities in the Nassarius egg plasma membrane. It is speculated that the observed animal-vegetal polarity in the organization of the egg membrane might play an important role in the process of cell diversification during early development.

  6. Ultrafine and respirable particle exposure during vehicle fire suppression.

    PubMed

    Evans, Douglas E; Fent, Kenneth W

    2015-10-01

    Vehicle fires are a common occurrence, yet few studies have reported exposures associated with burning vehicles. This article presents an assessment of firefighters' potential for ultrafine and respirable particle exposure during vehicle fire suppression training. Fires were initiated within the engine compartment and passenger cabins of three salvaged vehicles, with subsequent water suppression by fire crews. Firefighter exposures were monitored with an array of direct reading particle and air quality instruments. A flexible metallic duct and blower drew contaminants to the instrument array, positioned at a safe distance from the burning vehicles, with the duct inlet positioned at the nozzle operator's shoulder. The instruments measured the particle number, active surface area, respirable particle mass, photoelectric response, aerodynamic particle size distributions, and air quality parameters. Although vehicle fires were suppressed quickly (<10 minutes), firefighters may be exposed to short duration, high particle concentration episodes during fire suppression, which are orders of magnitude greater than the ambient background concentration. A maximum transient particle concentration of 1.21 × 10(7) particles per cm(3), 170 mg m(-3) respirable particle mass, 4700 μm(2) cm(-3) active surface area and 1400 (arbitrary units) in photoelectric response were attained throughout the series of six fires. Expressed as fifteen minute time-weighted averages, engine compartment fires averaged 5.4 × 10(4) particles per cm(3), 0.36 mg m(-3) respirable particle mass, 92 μm(2) cm(-3) active particle surface area and 29 (arbitrary units) in photoelectric response. Similarly, passenger cabin fires averaged 2.04 × 10(5) particles per cm(3), 2.7 mg m(-3) respirable particle mass, 320 μm(2) cm(-3) active particle surface area, and 34 (arbitrary units) in photoelectric response. Passenger cabin fires were a greater potential source of exposure than engine compartment fires. The wind direction and the relative position of the fire crew to the stationary burning vehicle played a primary role in fire crews' potential for exposure. We recommend that firefighters wear self-contained breathing apparatus during all phases of the vehicle fire response to significantly reduce their potential for particulate, vapor, and gaseous exposures.

  7. Expected scientific performance of the three spectrometers on the extreme ultraviolet explorer

    NASA Technical Reports Server (NTRS)

    Vallerga, J. V.; Jelinsky, P.; Vedder, P. W.; Malina, R. F.

    1990-01-01

    The expected in-orbit performance of the three spectrometers included on the Extreme Ultraviolet Explorer astronomical satellite is presented. Recent calibrations of the gratings, mirrors and detectors using monochromatic and continuum EUV light sources allow the calculation of the spectral resolution and throughput of the instrument. An effective area range of 0.2 to 2.8 sq cm is achieved over the wavelength range 70-600 A with a peak spectral resolution (FWHM) of 360 assuming a spacecraft pointing knowledge of 10 arc seconds (FWHM). For a 40,000 sec observation, the average 3 sigma sensitivity to a monochromatic line source is 0.003 photons/sq cm s. Simulated observations of known classes of EUV sources, such as hot white dwarfs, and cataclysmic variables are also presented.

  8. Predicting Summer Dryness Under a Warmer Climate: Modeling Land Surface Processes in the Midwestern United States

    NASA Astrophysics Data System (ADS)

    Winter, J. M.; Eltahir, E. A.

    2009-12-01

    One of the most significant impacts of climate change is the potential alteration of local hydrologic cycles over agriculturally productive areas. As the world’s food supply continues to be taxed by its burgeoning population, a greater percentage of arable land will need to be utilized and land currently producing food must become more efficient. This study seeks to quantify the effects of climate change on soil moisture in the American Midwest. A series of 24-year numerical experiments were conducted to assess the ability of Regional Climate Model Version 3 coupled to Integrated Biosphere Simulator (RegCM3-IBIS) and Biosphere-Atmosphere Transfer Scheme 1e (RegCM3-BATS1e) to simulate the observed hydroclimatology of the midwestern United States. Model results were evaluated using NASA Surface Radiation Budget, NASA Earth Radiation Budget Experiment, Illinois State Water Survey, Climate Research Unit Time Series 2.1, Global Soil Moisture Data Bank, and regional-scale estimations of evapotranspiration. The response of RegCM3-IBIS and RegCM3-BATS1e to a surrogate climate change scenario, a warming of 3oC at the boundaries and doubling of CO2, was explored. Precipitation increased significantly during the spring and summer in both RegCM3-IBIS and RegCM3-BATS1e, leading to additional runoff. In contrast, enhancement of evapotranspiration and shortwave radiation were modest. Soil moisture remained relatively unchanged in RegCM3-IBIS, while RegCM3-BATS1e exhibited some fall and winter wetting.

  9. The cryoablation of lung tissue using liquid nitrogen in gel and in the ex vivo pig lung.

    PubMed

    Nomori, Hiroaki; Yamazaki, Ikuo; Kondo, Toshiya; Kanno, Masaya

    2017-02-01

    To examine the efficiency of cryoablation using liquid nitrogen in lung tissue, we measured the size and temperature distribution of the frozen area (iceball) in gel and in the ex vivo pig lungs. Cryoprobes with diameters of 2.4 and 3.4 mm (2.4D and 3.4D, respectively) were used. Three temperature sensors were positioned at the surface of the cryoprobe and at distances of 0.5 and 1.5 cm from the cryoprobe. The ex vivo pig lungs were perfused with 37 °C saline and inflated using ventilator to simulate in vivo lung conditions. In gel, the 2.4D and 3.4D probes made iceballs of 3.9 ± 0.1 and 4.8 ± 0.3 cm in diameter, respectively, and the temperature at 1.5 cm from those probes reached -32 ± 8 and -53 ± 5 °C, respectively. In the pig lung, the 2.4D and 3.4D probes made iceballs of 5.2 ± 0.1 and 5.5 ± 0.4 cm in diameter, respectively, and the temperature at 1.5 cm from these probes reached -49 ± 5 and -58 ± 3 °C, respectively. Liquid nitrogen cryoablation using both 2.4D and 3.4D probes made iceballs that were of sufficient size, and effective temperatures were reached in both gel and the ex vivo pig lung.

  10. A new agent for flap survival – Hippophae rhamnoides L. (sea buckthorn): An experimental study in rats

    PubMed Central

    Emsen, Ilteris Murat

    2005-01-01

    Hippophae rhamnoides L. (sea buckthorn) is a member of the Elaeagnaceae family, and is a temperate bush native to Europe and Asia. The antioxidant activity of H rhamnoides L. has been shown in vitro cell culture and animal studies. Different fractions of H rhamnoides L. fruits inhibit 2,2-azobis-(2,4 dimethylvaleronitrile) and ascorbate iron-induced lipid peroxidations in vitro. H rhamnoides L., as well as vitamin E, decrease the malondialdehyde content in hyperlipidemic rabbit serum-cultured smooth muscle cells. The aim of the present study was to investigate, in a rat model, the potential effect of H rhamnoides L. on survival of random pattern skin flaps. For this purpose, 30 Wistar Albino rats were used, and a McFarlane-type caudally based skin flap was created on the dorsum of the rat (2.5 cm × 8 cm). Rats were divided into three groups: one control (group A) and two treatment groups (groups B and C). H rhamnoides L. was administered orally to the experimental groups: group B received a single 15 mg/kg dose per day and group C received 15 mg/kg twice per day. The areas and lengths of flap necrosis were measured in each group. The extent of necrotic flap areas were evaluated as length and area of total flap area, and differences were studied by Student’s t tests. The areas and lengths of necrosis of skin flaps decreased depending on H rhamnoides L., but viability of the flaps treated with 15 mg/kg/day was not significantly different from the control group. The rats receiving H rhamnoides L. 15 mg/kg twice per day had the highest flap survival rate (P<0.001). In conclusion, H rhamnoides L. may have a dose-dependent effect to increase flap survival in random skin flaps. PMID:24227931

  11. Avulsion of the puborectalis muscle is associated with asymmetry of the levator hiatus.

    PubMed

    Dietz, H P; Bhalla, R; Chantarasorn, V; Shek, K L

    2011-06-01

    To determine the degree of levator hiatal asymmetry in women with unilateral avulsion of the puborectalis muscle in order to estimate the likely effect of successful reconstruction. We reviewed datasets of women seen between May 2005 and January 2009 in a tertiary urogynecological unit. Archived ultrasound volume datasets were analyzed for hiatal dimensions and puborectalis muscle trauma in patients with unilateral avulsion. From 929 eligible datasets we identified 71 patients with isolated complete unilateral tears. Unilateral avulsion was associated with a significant increase in hiatal area (P ≤ 0.002). Relative to a hypothetical normal hiatus (intact hemi-area × 2), avulsion was associated with a larger hiatus on Valsalva maneuver (+2.1 cm(2) or 7%). Unilateral puborectalis muscle avulsion results in an asymmetric increase in the size of the levator hiatus. This increase is relatively minor, accounting for < 10% of hiatal area. Surgical repair of an avulsion may have only limited effects on hiatal dimensions. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  12. High energy density asymmetric supercapacitors with a nickel oxide nanoflake cathode and a 3D reduced graphene oxide anode

    NASA Astrophysics Data System (ADS)

    Luan, Feng; Wang, Gongming; Ling, Yichuan; Lu, Xihong; Wang, Hanyu; Tong, Yexiang; Liu, Xiao-Xia; Li, Yat

    2013-08-01

    Here we demonstrate a high energy density asymmetric supercapacitor with nickel oxide nanoflake arrays as the cathode and reduced graphene oxide as the anode. Nickel oxide nanoflake arrays were synthesized on a flexible carbon cloth substrate using a seed-mediated hydrothermal method. The reduced graphene oxide sheets were deposited on three-dimensional (3D) nickel foam by hydrothermal treatment of nickel foam in graphene oxide solution. The nanostructured electrodes provide a large effective surface area. The asymmetric supercapacitor device operates with a voltage of 1.7 V and achieved a remarkable areal capacitance of 248 mF cm-2 (specific capacitance of 50 F g-1) at a charge/discharge current density of 1 mA cm-2 and a maximum energy density of 39.9 W h kg-1 (based on the total mass of active materials of 5.0 mg). Furthermore, the device showed an excellent charge/discharge cycling performance in 1.0 M KOH electrolyte at a current density of 5 mA cm-2, with a capacitance retention of 95% after 3000 cycles.

  13. High energy density asymmetric supercapacitors with a nickel oxide nanoflake cathode and a 3D reduced graphene oxide anode.

    PubMed

    Luan, Feng; Wang, Gongming; Ling, Yichuan; Lu, Xihong; Wang, Hanyu; Tong, Yexiang; Liu, Xiao-Xia; Li, Yat

    2013-09-07

    Here we demonstrate a high energy density asymmetric supercapacitor with nickel oxide nanoflake arrays as the cathode and reduced graphene oxide as the anode. Nickel oxide nanoflake arrays were synthesized on a flexible carbon cloth substrate using a seed-mediated hydrothermal method. The reduced graphene oxide sheets were deposited on three-dimensional (3D) nickel foam by hydrothermal treatment of nickel foam in graphene oxide solution. The nanostructured electrodes provide a large effective surface area. The asymmetric supercapacitor device operates with a voltage of 1.7 V and achieved a remarkable areal capacitance of 248 mF cm(-2) (specific capacitance of 50 F g(-1)) at a charge/discharge current density of 1 mA cm(-2) and a maximum energy density of 39.9 W h kg(-1) (based on the total mass of active materials of 5.0 mg). Furthermore, the device showed an excellent charge/discharge cycling performance in 1.0 M KOH electrolyte at a current density of 5 mA cm(-2), with a capacitance retention of 95% after 3000 cycles.

  14. [Skin graft combined with thorax wire fastening for repairing postoperative coloboma After resection of chest back giant nevus].

    PubMed

    Zhao, Weimin; Dai, Tao; Yuan, Depin; Zhang, Gongbao

    2011-11-01

    To observe the effectiveness of skin graft combined with thorax wire fastening for repairing postoperative coloboma after resection of chest back giant nevus. Between June 2007 and October 2010, 17 cases of chest back giant nevus were treated. There were 7 males and 10 females, aged from 3 years and 6 months to 15 years (mean, 8 years). The size of giant nevus was 20 cm x 12 cm to 60 cm x 50 cm. Two cases of them were ever treated by laser, while the others were never treated. The check before operation showed ulcer of the skin and effusion in 2 cases, hard skin in 3 cases, hair growth in 7 cases, and normal in 5 cases. Five cases had serious itch. After giant nevus was cut off, thorax wire was fastened to reduce the wound area, and then the intermediate split thickness skin graft of thigh was used to repair the wound. Comprehensive anti-scar treatment was given postoperatively. The wound size was (2 110.74 +/- 725.69) cm2 after resection of giant nevus, and was (1 624.94 +/- 560.57) cm2 after thorax wire fastening, showing significant difference (t = 9.006, P = 0.001). All the grafting skin survived; the incision and wound at donor site healed by first intention. The patients were followed up 6 months to 2 years (mean, 13 months). No scar proliferation or contracture occurred. The skin color and elasticity were similar to the normal skin; the nipple, navel, and other local apparatus were not shifted after operation. It can reduce donor site of skin and postoperative scar, and achieve satisfactory appearance to cover the wound by skin graft combined with thorax wire fastening after chest back giant nevus was cut off.

  15. Facilitating the Adoption of Contingency Management for the Treatment of Substance Use Disorders

    PubMed Central

    Roll, John M; Madden, Gregory J; Rawson, Richard; Petry, Nancy M

    2009-01-01

    Contingency management (CM) is an effective treatment strategy for addressing many types of substance abuse disorders and associated problems. Nonetheless, CM protocols have not been widely embraced by community-based treatment providers. Exploration of the viability of CM outside of a research context remains largely an academic pursuit. In this paper, we outline several areas that may hinder the transfer of CM technology into community-based practice settings, review the literature that may address these barriers, and offer suggestions to researchers for overcoming them. PMID:22477692

  16. Fuel-reduction management alters plant composition, carbon and nitrogen pools, and soil thaw in Alaskan boreal forest

    USGS Publications Warehouse

    Melvin, April M.; Celis, Gerardo; Johnstone, Jill F.; McGuire, A. David; Genet, Helene; Schuur, Edward A.G.; Rupp, T. Scott; Mack, Michelle C.

    2018-01-01

    Increasing wildfire activity in Alaska's boreal forests has led to greater fuel-reduction management. Management has been implemented to reduce wildfire spread, but the ecological impacts of these practices are poorly known. We quantified the effects of hand-thinning and shearblading on above- and belowground stand characteristics, plant species composition, carbon (C) and nitrogen (N) pools, and soil thaw across 19 black spruce (Picea mariana) dominated sites in interior Alaska treated 2-12 years prior to sampling. The density of deciduous tree seedlings was significantly higher in shearbladed areas compared to unmanaged forest (6.4 vs. 0.1 stems m−2), and unmanaged stands exhibited the highest mean density of conifer seedlings and layers (1.4 stems m−2). Understory plant community composition was most similar between unmanaged and thinned stands. Shearblading resulted in a near complete loss of aboveground tree biomass C pools while thinning approximately halved the C pool size (1.2 kg C m−2 compared to 3.1 kg C m−2 in unmanaged forest). Significantly smaller soil organic layer (SOL) C and N pools were observed in shearbladed stands (3.2 kg C m−2 and 116.8 g N m−2) relative to thinned (6.0 kg C m−2 and 192.2 g N m−2) and unmanaged (5.9 kg C m−2 and 178.7 g N m−2) stands. No difference in C and N pool sizes in the uppermost 10 cm of mineral soil was observed among stand types. Total C stocks for measured pools was 2.6 kg C m−2 smaller in thinned stands and 5.8 kg C m−2smaller in shearbladed stands when compared to unmanaged forest. Soil thaw depth averaged 13 cm deeper in thinned areas and 46 cm deeper in shearbladed areas relative to adjacent unmanaged stands, although variability was high across sites. Deeper soil thaw was linked to shallower SOL depth for unmanaged stands and both management types, however for any given SOL depth, thaw tended to be deeper in shearbladed areas compared to unmanaged forest. These findings indicate that fuel-reduction management alters plant community composition, C and N pools, and soil thaw depth, with consequences for ecosystem structure and function beyond those intended for fire management.

  17. Infrared spectra in monitoring biochemical parameters of human blood

    NASA Astrophysics Data System (ADS)

    Prabhakar, S.; Jain, N.; Singh, R. A.

    2012-05-01

    Infrared spectroscopy is gaining recognition as a promising method. The infrared spectra of selected regions (2000-400cm-1) of blood tissue samples are reported. Present study related to the role of spectral peak fitting in the study of human blood and quantitative interpretations of infrared spectra based on chemometrics. The spectral variations are interpreted in terms of the biochemical and pathological processes involved. The mean RNA/DNA ratio of fitted intensities and analytical area as calculated from the transmittance peaks at 1121cm-1/1020cm-1 is found to be 0.911A.U and 2.00A.U. respectively. The ratio of 1659cm-1/1544cm-1 (amide-I/amide-II) bands is found to shed light on the change in the DNA content. The ratio of amide-I/amide-II is almost unity (≈1.054) for blood spectra. The deviation from unity is an indication of DNA absorption from the RBC cells. The total phosphate content has found to be 25.09A.U. The level for glycogen/phosphate ratio (areas under peaks 1030cm-1/1082cm-1) is found to be 0.286A.U. The ratio of unsaturated and saturated carbonyl compounds (C=O) in blood samples is in form of esters and the analytical areas under the spectral peaks at 1740cm-1 and 1731cm-1 for unsaturated esters and saturated esters respectively found to be 0.618A.U.

  18. Full synergistic effect of hydrothermal NiCo2O4 nanosheets/CuCo2O4 nanocones supported on Ni foam for high-performance asymmetric supercapacitors

    NASA Astrophysics Data System (ADS)

    Wen, Shiyang; Liu, Yu; Bai, Hongye; Shao, Rong; Xu, Wei; Shi, Weidong

    2018-06-01

    In this work, a series of NiCo2O4/CuCo2O4 composites were prepared by a two-step hydrothermal method. The optimized NiCo2O4/CuCo2O4 electrode shows more than 5 times area capacitance (4.97 F cm-2) than pure NiCo2O4 at the current density of 1 mA cm-2. The best performance of sample assembled an asymmetric supercapacitor could reach up to 42 F g-1 at the current density of 1 A g-1. In addition, the maximum energy density of 15 W h kg-1 was achieved with the power density of 814 W kg-1. The as-prepared active electrode material also reveals excellent cycling stability with 90.6% capacitance retention after 5000 cycles. These results indicate potential application in developing energy storage devices with high energy density power density.

  19. High-Quality Solution-Processed Silicon Oxide Gate Dielectric Applied on Indium Oxide Based Thin-Film Transistors.

    PubMed

    Jaehnike, Felix; Pham, Duy Vu; Anselmann, Ralf; Bock, Claudia; Kunze, Ulrich

    2015-07-01

    A silicon oxide gate dielectric was synthesized by a facile sol-gel reaction and applied to solution-processed indium oxide based thin-film transistors (TFTs). The SiOx sol-gel was spin-coated on highly doped silicon substrates and converted to a dense dielectric film with a smooth surface at a maximum processing temperature of T = 350 °C. The synthesis was systematically improved, so that the solution-processed silicon oxide finally achieved comparable break downfield strength (7 MV/cm) and leakage current densities (<10 nA/cm(2) at 1 MV/cm) to thermally grown silicon dioxide (SiO2). The good quality of the dielectric layer was successfully proven in bottom-gate, bottom-contact metal oxide TFTs and compared to reference TFTs with thermally grown SiO2. Both transistor types have field-effect mobility values as high as 28 cm(2)/(Vs) with an on/off current ratio of 10(8), subthreshold swings of 0.30 and 0.37 V/dec, respectively, and a threshold voltage close to zero. The good device performance could be attributed to the smooth dielectric/semiconductor interface and low interface trap density. Thus, the sol-gel-derived SiO2 is a promising candidate for a high-quality dielectric layer on many substrates and high-performance large-area applications.

  20. A 5 x 40 cm rectangular-beam multipole ion source

    NASA Technical Reports Server (NTRS)

    Robinson, R. S.; Kaufman, H. R.; Haynes, C. M.

    1981-01-01

    A rectangular ion source particularly suited for the continuous sputter processing of materials over a wide area is discussed. A multipole magnetic field configuration was used to design an ion source with a 5 x 40 cm beam area, while a three-grid ion optics system was used to maximize ion current density at the design ion energy of 500 eV. An average extracted current density of about 4 mA/sq cm could be obtained from 500 eV Ar ions. The difference between the experimental performance and the design value of 6 mA/sq cm is attributed to grid misalignment due to thermal expansion. The discharge losses at typical operating conditions ranged from about 600 to 1000 eV/ion, in reasonable agreement with the design value of 800 eV/ion. The use of multiple rectangular-beam ion sources to process wider areas than would be possible with a single source was also studied, and the most uniform coverage was found to be obtainable with a 0 to 2 cm overlap.

Top