Development of a DC-DC conversion powering scheme for the CMS Phase-1 pixel upgrade
NASA Astrophysics Data System (ADS)
Feld, L.; Fimmers, C.; Karpinski, W.; Klein, K.; Lipinski, M.; Preuten, M.; Rauch, M.; Rittich, D.; Sammet, J.; Wlochal, M.
2014-01-01
A novel powering scheme based on the DC-DC conversion technique will be exploited to power the CMS Phase-1 pixel detector. DC-DC buck converters for the CMS pixel project have been developed, based on the AMIS5 ASIC designed by CERN. The powering system of the Phase-1 pixel detector is described and the performance of the converter prototypes is detailed, including power efficiency, stability of the output voltage, shielding, and thermal management. Results from a test of the magnetic field tolerance of the DC-DC converters are reported. System tests with pixel modules using many components of the future pixel barrel system are summarized. Finally first impressions from a pre-series of 200 DC-DC converters are presented.
Status and Plan for The Upgrade of The CMS Pixel Detector
NASA Astrophysics Data System (ADS)
Lu, Rong-Shyang; CMS Collaboration
2016-04-01
The silicon pixel detector is the innermost component of the CMS tracking system and plays a crucial role in the all-silicon CMS tracker. While the current pixel tracker is designed for and performing well at an instantaneous luminosity of up to 1 ×1034cm-2s-1, it can no longer be operated efficiently at significantly higher values. Based on the strong performance of the LHC accelerator, it is anticipated that peak luminosities of two times the design luminosity are likely to be reached before 2018 and perhaps significantly exceeded in the running period until 2022, referred to as LHC Run 3. Therefore, an upgraded pixel detector, referred to as the phase 1 upgrade, is planned for the year-end technical stop in 2016. With a new pixel readout chip (ROC), an additional fourth layer, two additional endcap disks, and a significantly reduced material budget the upgraded pixel detector will be able to sustain the efficiency of the pixel tracker at the increased requirements imposed by high luminosities and pile-up. The main new features of the upgraded pixel detector will be an ultra-light mechanical design, a digital readout chip with higher rate capability and a new cooling system. These and other design improvements, along with results of Monte Carlo simulation studies for the expected performance of the new pixel detector, will be discussed and compared to those of the current CMS detector.
Prototypes and system test stands for the Phase 1 upgrade of the CMS pixel detector
Hasegawa, S.
2016-04-23
The CMS pixel phase-1 upgrade project replaces the current pixel detector with an upgraded system with faster readout electronics during the extended year-end technical stop of 2016/2017. New electronics prototypes for the system have been developed, and tests in a realistic environment for a comprehensive evaluation are needed. A full readout test stand with either the same hardware as used in the current CMS pixel detector or the latest prototypes of upgrade electronics has been built. The setup enables the observation and investigation of a jitter increase in the data line associated with trigger rate increases. This effect is duemore » to the way in which the clock and trigger distribution is implemented in CMS. A new prototype of the electronics with a PLL based on a voltage controlled quartz crystal oscillator (QPLL), which works as jitter filter, in the clock distribution path was produced. With the test stand, it was confirmed that the jitter increase is not seen with the prototype, and also good performance was confirmed at the expected detector operation temperature ($-$20 °C).« less
A new data acquisition system for the CMS Phase 1 pixel detector
NASA Astrophysics Data System (ADS)
Kornmayer, A.
2016-12-01
A new pixel detector will be installed in the CMS experiment during the extended technical stop of the LHC at the beginning of 2017. The new pixel detector, built from four layers in the barrel region and three layers on each end of the forward region, is equipped with upgraded front-end readout electronics, specifically designed to handle the high particle hit rates created in the LHC environment. The DAQ back-end was entirely redesigned to handle the increased number of readout channels, the higher data rates per channel and the new digital data format. Based entirely on the microTCA standard, new front-end controller (FEC) and front-end driver (FED) cards have been developed, prototyped and produced with custom optical link mezzanines mounted on the FC7 AMC and custom firmware. At the same time as the new detector is being assembled, the DAQ system is set up and its integration into the CMS central DAQ system tested by running the pilot blade detector already installed in CMS. This work describes the DAQ system, integration tests and gives an outline for the activities up to commissioning the final system at CMS in 2017.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwan, Simon; Lei, CM; Menasce, Dario
An all silicon pixel telescope has been assembled and used at the Fermilab Test Beam Facility (FTBF) since 2009 to provide precise tracking information for different test beam experiments with a wide range of Detectors Under Test (DUTs) requiring high resolution measurement of the track impact point. The telescope is based on CMS pixel modules left over from the CMS forward pixel production. Eight planes are arranged to achieve a resolution of less than 8 μm on the 120 GeV proton beam transverse coordinate at the DUT position. In order to achieve such resolution with 100 × 150 μm 2more » pixel cells, the planes were tilted to 25 degrees to maximize charge sharing between pixels. Crucial for obtaining this performance is the alignment software, called Monicelli, specifically designed and optimized for this system. This paper will describe the telescope hardware, the data acquisition system and the alignment software constituting this particle tracking system for test beam users.« less
The pixel tracking telescope at the Fermilab Test Beam Facility
Kwan, Simon; Lei, CM; Menasce, Dario; ...
2016-03-01
An all silicon pixel telescope has been assembled and used at the Fermilab Test Beam Facility (FTBF) since 2009 to provide precise tracking information for different test beam experiments with a wide range of Detectors Under Test (DUTs) requiring high resolution measurement of the track impact point. The telescope is based on CMS pixel modules left over from the CMS forward pixel production. Eight planes are arranged to achieve a resolution of less than 8 μm on the 120 GeV proton beam transverse coordinate at the DUT position. In order to achieve such resolution with 100 × 150 μm 2more » pixel cells, the planes were tilted to 25 degrees to maximize charge sharing between pixels. Crucial for obtaining this performance is the alignment software, called Monicelli, specifically designed and optimized for this system. This paper will describe the telescope hardware, the data acquisition system and the alignment software constituting this particle tracking system for test beam users.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hasegawa, S.
The CMS pixel phase-1 upgrade project replaces the current pixel detector with an upgraded system with faster readout electronics during the extended year-end technical stop of 2016/2017. New electronics prototypes for the system have been developed, and tests in a realistic environment for a comprehensive evaluation are needed. A full readout test stand with either the same hardware as used in the current CMS pixel detector or the latest prototypes of upgrade electronics has been built. The setup enables the observation and investigation of a jitter increase in the data line associated with trigger rate increases. This effect is duemore » to the way in which the clock and trigger distribution is implemented in CMS. A new prototype of the electronics with a PLL based on a voltage controlled quartz crystal oscillator (QPLL), which works as jitter filter, in the clock distribution path was produced. With the test stand, it was confirmed that the jitter increase is not seen with the prototype, and also good performance was confirmed at the expected detector operation temperature ($-$20 °C).« less
Hit efficiency study of CMS prototype forward pixel detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Dongwook; /Johns Hopkins U.
2006-01-01
In this paper the author describes the measurement of the hit efficiency of a prototype pixel device for the CMS forward pixel detector. These pixel detectors were FM type sensors with PSI46V1 chip readout. The data were taken with the 120 GeV proton beam at Fermilab during the period of December 2004 to February 2005. The detectors proved to be highly efficient (99.27 {+-} 0.02%). The inefficiency was primarily located near the corners of the individual pixels.
Alignment of the CMS Tracker: Latest Results from LHC Run-II
NASA Astrophysics Data System (ADS)
Mittag, Gregor; CMS Collaboration
2017-10-01
The all-silicon design of the tracking system of the CMS experiment provides excellent measurements of charged-particle tracks and an efficient tagging of jets. Conditions of the CMS tracker changed repeatedly during the 2015/2016 shutdown and the 2016 data-taking period. Still the true position and orientation of each of the 15 148 silicon strip and 1440 silicon pixel modules need to be known with high precision for all intervals. The alignment constants also need to be promptly re-adjusted each time the state of the CMS magnet is changed between 0T and 3.8 T. Latest Run-II results of the CMS tracker alignment and resolution performance are presented, which are obtained using several millions of reconstructed tracks from collision and cosmic-ray data of 2016. The geometries and the resulting performance of physics observables are carefully validated. In addition to the offline alignment, an online procedure has been put in place which continuously monitors movements of the pixel high-level structures and triggers updates of the alignment constants if certain thresholds are exceeded.
Test beam performance measurements for the Phase I upgrade of the CMS pixel detector
NASA Astrophysics Data System (ADS)
Dragicevic, M.; Friedl, M.; Hrubec, J.; Steininger, H.; Gädda, A.; Härkönen, J.; Lampén, T.; Luukka, P.; Peltola, T.; Tuominen, E.; Tuovinen, E.; Winkler, A.; Eerola, P.; Tuuva, T.; Baulieu, G.; Boudoul, G.; Caponetto, L.; Combaret, C.; Contardo, D.; Dupasquier, T.; Gallbit, G.; Lumb, N.; Mirabito, L.; Perries, S.; Vander Donckt, M.; Viret, S.; Bonnin, C.; Charles, L.; Gross, L.; Hosselet, J.; Tromson, D.; Feld, L.; Karpinski, W.; Klein, K.; Lipinski, M.; Pierschel, G.; Preuten, M.; Rauch, M.; Wlochal, M.; Aldaya, M.; Asawatangtrakuldee, C.; Beernaert, K.; Bertsche, D.; Contreras-Campana, C.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Gallo, E.; Garay Garcia, J.; Hansen, K.; Haranko, M.; Harb, A.; Hauk, J.; Keaveney, J.; Kalogeropoulos, A.; Kleinwort, C.; Lohmann, W.; Mankel, R.; Maser, H.; Mittag, G.; Muhl, C.; Mussgiller, A.; Pitzl, D.; Reichelt, O.; Savitskyi, M.; Schütze, P.; Sola, V.; Spannagel, S.; Walsh, R.; Zuber, A.; Biskop, H.; Buhmann, P.; Centis-Vignali, M.; Garutti, E.; Haller, J.; Hoffmann, M.; Klanner, R.; Lapsien, T.; Matysek, M.; Perieanu, A.; Scharf, Ch.; Schleper, P.; Schmidt, A.; Schwandt, J.; Sonneveld, J.; Steinbrück, G.; Vormwald, B.; Wellhausen, J.; Abbas, M.; Amstutz, C.; Barvich, T.; Barth, Ch.; Boegelspacher, F.; De Boer, W.; Butz, E.; Casele, M.; Colombo, F.; Dierlamm, A.; Freund, B.; Hartmann, F.; Heindl, S.; Husemann, U.; Kornmeyer, A.; Kudella, S.; Muller, Th.; Simonis, H. J.; Steck, P.; Weber, M.; Weiler, Th.; Kiss, T.; Siklér, F.; Tölyhi, T.; Veszprémi, V.; Cariola, P.; Creanza, D.; De Palma, M.; De Robertis, G.; Fiore, L.; Franco, M.; Loddo, F.; Sala, G.; Silvestris, L.; Maggi, G.; My, S.; Selvaggi, G.; Albergo, S.; Cappello, G.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Saizu, M. A.; Tricomi, A.; Tuve, C.; Focardi, E.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Malvezzi, S.; Manzoni, R. A.; Menasce, D.; Moroni, L.; Pedrini, D.; Azzi, P.; Bacchetta, N.; Bisello, D.; Dall'Osso, M.; Pozzobon, N.; Tosi, M.; Alunni Solestizi, L.; Biasini, M.; Bilei, G. M.; Cecchi, C.; Checcucci, B.; Ciangottini, D.; Fanò, L.; Gentsos, C.; Ionica, M.; Leonardi, R.; Manoni, E.; Mantovani, G.; Marconi, S.; Mariani, V.; Menichelli, M.; Modak, A.; Morozzi, A.; Moscatelli, F.; Passeri, D.; Placidi, P.; Postolache, V.; Rossi, A.; Saha, A.; Santocchia, A.; Storchi, L.; Spiga, D.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Basti, A.; Boccali, T.; Borrello, L.; Bosi, F.; Castaldi, R.; Ceccanti, M.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Magazzu, G.; Mammini, P.; Mariani, F.; Mazzoni, E.; Messineo, A.; Moggi, A.; Morsani, F.; Palla, F.; Palmonari, F.; Profeti, A.; Raffaelli, F.; Ragonesi, A.; Rizzi, A.; Soldani, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Abbaneo, D.; Ahmed, I.; Albert, E.; Auzinger, G.; Berruti, G.; Bonnaud, J.; Daguin, J.; D'Auria, A.; Detraz, S.; Dondelewski, O.; Engegaard, B.; Faccio, F.; Frank, N.; Gill, K.; Honma, A.; Kornmayer, A.; Labaza, A.; Manolescu, F.; McGill, I.; Mersi, S.; Michelis, S.; Onnela, A.; Ostrega, M.; Pavis, S.; Peisert, A.; Pernot, J.-F.; Petagna, P.; Postema, H.; Rapacz, K.; Sigaud, C.; Tropea, P.; Troska, J.; Tsirou, A.; Vasey, F.; Verlaat, B.; Vichoudis, P.; Zwalinski, L.; Bachmair, F.; Becker, R.; di Calafiori, D.; Casal, B.; Berger, P.; Djambazov, L.; Donega, M.; Grab, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lustermann, W.; Mangano, B.; Marionneau, M.; Martinez Ruiz del Arbol, P.; Masciovecchio, M.; Meinhard, M.; Perozzi, L.; Roeser, U.; Starodumov, A.; Tavolaro, V.; Wallny, R.; Zhu, D.; Amsler, C.; Bösiger, K.; Caminada, L.; Canelli, F.; Chiochia, V.; de Cosa, A.; Galloni, C.; Hreus, T.; Kilminster, B.; Lange, C.; Maier, R.; Ngadiuba, J.; Pinna, D.; Robmann, P.; Taroni, S.; Yang, Y.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Kaestli, H.-C.; Kotlinski, D.; Langenegger, U.; Meier, B.; Rohe, T.; Streuli, S.; Chen, P.-H.; Dietz, C.; Fiori, F.; Grundler, U.; Hou, W.-S.; Lu, R.-S.; Moya, M.; Tsai, J.-F.; Tzeng, Y. M.; Cussans, D.; Goldstein, J.; Grimes, M.; Newbold, D.; Hobson, P.; Reid, I. D.; Auzinger, G.; Bainbridge, R.; Dauncey, P.; Hall, G.; James, T.; Magnan, A.-M.; Pesaresi, M.; Raymond, D. M.; Uchida, K.; Durkin, T.; Harder, K.; Shepherd-Themistocleous, C.; Chertok, M.; Conway, J.; Conway, R.; Flores, C.; Lander, R.; Pellett, D.; Ricci-Tam, F.; Squires, M.; Thomson, J.; Yohay, R.; Burt, K.; Ellison, J.; Hanson, G.; Olmedo, M.; Si, W.; Yates, B. R.; Dominguez, A.; Bartek, R.; Bentele, B.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Leontsinis, S.; Mulholland, T.; Stenson, K.; Wagner, S. R.; Apresyan, A.; Bolla, G.; Burkett, K.; Butler, J. N.; Canepa, A.; Cheung, H. W. K.; Christian, D.; Cooper, W. E.; Deptuch, G.; Derylo, G.; Gingu, C.; Grünendahl, S.; Hasegawa, S.; Hoff, J.; Howell, J.; Hrycyk, M.; Jindariani, S.; Johnson, M.; Kahlid, F.; Kwan, S.; Lei, C. M.; Lipton, R.; Lopes De Sá, R.; Liu, T.; Los, S.; Matulik, M.; Merkel, P.; Nahn, S.; Prosser, A.; Rivera, R.; Schneider, B.; Sellberg, G.; Shenai, A.; Siehl, K.; Spiegel, L.; Tran, N.; Uplegger, L.; Voirin, E.; Berry, D. R.; Chen, X.; Ennesser, L.; Evdokimov, A.; Gerber, C. E.; Makauda, S.; Mills, C.; Sandoval Gonzalez, I. D.; Alimena, J.; Antonelli, L. J.; Francis, B.; Hart, A.; Hill, C. S.; Parashar, N.; Stupak, J.; Bortoletto, D.; Bubna, M.; Hinton, N.; Jones, M.; Miller, D. H.; Shi, X.; Baringer, P.; Bean, A.; Khalil, S.; Kropivnitskaya, A.; Majumder, D.; Schmitz, E.; Wilson, G.; Ivanov, A.; Mendis, R.; Mitchell, T.; Skhirtladze, N.; Taylor, R.; Anderson, I.; Fehling, D.; Gritsan, A.; Maksimovic, P.; Martin, C.; Nash, K.; Osherson, M.; Swartz, M.; Xiao, M.; Acosta, J. G.; Cremaldi, L. M.; Oliveros, S.; Perera, L.; Summers, D.; Bloom, K.; Claes, D. R.; Fangmeier, C.; Gonzalez Suarez, R.; Monroy, J.; Siado, J.; Bartz, E.; Gershtein, Y.; Halkiadakis, E.; Kyriacou, S.; Lath, A.; Nash, K.; Osherson, M.; Schnetzer, S.; Stone, R.; Walker, M.; Malik, S.; Norberg, S.; Ramirez Vargas, J. E.; Alyari, M.; Dolen, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Kharchilava, A.; Nguyen, D.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; McDermott, K.; Mirman, N.; Rinkevicius, A.; Ryd, A.; Salvati, E.; Skinnari, L.; Soffi, L.; Tao, Z.; Thom, J.; Tucker, J.; Zientek, M.; Akgün, B.; Ecklund, K. M.; Kilpatrick, M.; Nussbaum, T.; Zabel, J.; D'Angelo, P.; Johns, W.; Rose, K.; Choudhury, S.; Korol, I.; Seitz, C.; Vargas Trevino, A.; Dolinska, G.
2017-05-01
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC . The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is 99.95 ± 0.05%, while the intrinsic spatial resolutions are 4.80 ± 0.25 μm and 7.99 ± 0.21 μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
Test beam performance measurements for the Phase I upgrade of the CMS pixel detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dragicevic, M.; Friedl, M.; Hrubec, J.
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. Here in this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency ismore » $$99.95\\pm0.05\\,\\%$$, while the intrinsic spatial resolutions are $$4.80\\pm0.25\\,\\mu \\mathrm{m}$$ and $$7.99\\pm0.21\\,\\mu \\mathrm{m}$$ along the $$100\\,\\mu \\mathrm{m}$$ and $$150\\,\\mu \\mathrm{m}$$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.« less
Test beam performance measurements for the Phase I upgrade of the CMS pixel detector
Dragicevic, M.; Friedl, M.; Hrubec, J.; ...
2017-05-30
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. Here in this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency ismore » $$99.95\\pm0.05\\,\\%$$, while the intrinsic spatial resolutions are $$4.80\\pm0.25\\,\\mu \\mathrm{m}$$ and $$7.99\\pm0.21\\,\\mu \\mathrm{m}$$ along the $$100\\,\\mu \\mathrm{m}$$ and $$150\\,\\mu \\mathrm{m}$$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.« less
Qualification and calibration tests of detector modules for the CMS Pixel Phase 1 upgrade
NASA Astrophysics Data System (ADS)
Zhu, D.; Backhaus, M.; Berger, P.; Meinhard, M.; Starodumov, A.; Tavolaro, V.
2018-01-01
In high energy particle physics, accelerator- and detector-upgrades always go hand in hand. The instantaneous luminosity of the Large Hadron Collider will increase to up to L = 2×1034cm-2s-1 during Run 2 until 2023. In order to cope with such luminosities, the pixel detector of the CMS experiment has been replaced early 2017. The so-called CMS Pixel phase 1 upgrade detector consists of 1184 modules with new design. An important production step is the module qualification and calibration, ensuring their proper functionality within the detector. This paper summarizes the qualification and calibration tests and results of modules used in the innermost two detector layers with focus on methods using module-internal calibration signals. Extended characterizations on pixel level such as electronic noise and bump bond connectivity, optimization of operational parameters, sensor quality and thermal stress resistance were performed using a customized setup with controlled environment. It could be shown that the selected modules have on average 0.55‰ ± 0.01‰ defective pixels and that all performance parameters stay within their specifications.
NASA Astrophysics Data System (ADS)
Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Doroshenko, J.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foster, J.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Gobbi, B.; Grim, G. P.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Lander, R.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L. S.; Pernicka, M.; Perera, L.; Pirollo, S.; Plano, R.; Procario, M.; Riester, J. L.; Roe, S.; Rott, C.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Zoeller, M.
2001-06-01
Diamond based pixel detectors are a promising radiation-hard technology for use at the LHC. We present first results on a CMS diamond pixel sensor. With a threshold setting of 2000 electrons, an average pixel efficiency of 78% was obtained for normally incident minimum ionizing particles.
The Development of the CMS Zero Degree Calorimeters to Derive the Centrality of AA Collisions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, Jeffrey Scott
The centrality of РЬРЬ collisions is derived using correlations from the zero degree calorimeter (ZDC) signal and pixel multiplicity at the Compact Muon Solenoid (CMS) Experiment using data from the heavy ion run in 2010. The method to derive the centrality takes the two-dimensional correlation between the ZDC and pixels and linearizes it for sorting events. The initial method for deriving the centrality at CMS uses the energy deposit in the HF detector, and it is compared to the centrality derived Ьу the correlations in ZDC and pixel multiplicity. This comparison highlights the similarities between the results of both methodsmore » in central collisions, as expected, and deviations in the results in peripheral collisions. The ZDC signals in peripheral collisions are selected Ьу low pixel multiplicity to oЬtain а ZDC neutron spectrum, which is used to effectively gain match both sides of the ZDC« less
The phase 1 upgrade of the CMS Pixel Front-End Driver
NASA Astrophysics Data System (ADS)
Friedl, M.; Pernicka, M.; Steininger, H.
2010-12-01
The pixel detector of the CMS experiment at the LHC is read out by analog optical links, sending the data to 9U VME Front-End Driver (FED) boards located in the electronics cavern. There are plans for the phase 1 upgrade of the pixel detector (2016) to add one more layer, while significantly cutting down the overall material budget. At the same time, the optical data transmission will be replaced by a serialized digital scheme. A plug-in board solution with a high-speed digital optical receiver has been developed for the Pixel-FED readout boards and will be presented along with first tests of the future optical link.
NASA Astrophysics Data System (ADS)
Oliveros Tautiva, Sandra Jimena
The Compact Muon Solenoid (CMS) is one of the two most important experiments at the Large Hadron Collider (LHC). The pixel detector is the component closest to the collision in CMS and it receives large doses of radiation which will affect its performance. The pixel detector will be replaced by a new one after four years. The aim is to reduce material in the sensitive zone of the new pixel detector, which leads to the implementation of a type of micro twisted pair cable that will replace the existing kapton cables and some connections will be eliminated. The purpose of this work was to study the viability of using these micro twisted pair cables in the existing 40 MHz analog readout. The electrical parameters of micro cables were determined, and operational tests were performed in a module using these cables for communicating and reading. Three different lengths of micro cables were used, 1.0, 1.5 and 2.0 m, in order to compare test results with those obtained using the kapton cable. It was found that the use of these cables does not affect the programming and reading of the pixels in one module, so the micro cables are viable to be used in place of the kapton cables.
Performance verification of the CMS Phase-1 Upgrade Pixel detector
NASA Astrophysics Data System (ADS)
Veszpremi, V.
2017-12-01
The CMS tracker consists of two tracking systems utilizing semiconductor technology: the inner pixel and the outer strip detectors. The tracker detectors occupy the volume around the beam interaction region between 3 cm and 110 cm in radius and up to 280 cm along the beam axis. The pixel detector consists of 124 million pixels, corresponding to about 2 m 2 total area. It plays a vital role in the seeding of the track reconstruction algorithms and in the reconstruction of primary interactions and secondary decay vertices. It is surrounded by the strip tracker with 10 million read-out channels, corresponding to 200 m 2 total area. The tracker is operated in a high-occupancy and high-radiation environment established by particle collisions in the LHC . The current strip detector continues to perform very well. The pixel detector that has been used in Run 1 and in the first half of Run 2 was, however, replaced with the so-called Phase-1 Upgrade detector. The new system is better suited to match the increased instantaneous luminosity the LHC would reach before 2023. It was built to operate at an instantaneous luminosity of around 2×1034 cm-2s-1. The detector's new layout has an additional inner layer with respect to the previous one; it allows for more efficient tracking with smaller fake rate at higher event pile-up. The paper focuses on the first results obtained during the commissioning of the new detector. It also includes challenges faced during the first data taking to reach the optimal measurement efficiency. Details will be given on the performance at high occupancy with respect to observables such as data-rate, hit reconstruction efficiency, and resolution.
NASA Astrophysics Data System (ADS)
Marconi, S.; Orfanelli, S.; Karagounis, M.; Hemperek, T.; Christiansen, J.; Placidi, P.
2017-02-01
A dedicated power analysis methodology, based on modern digital design tools and integrated with the VEPIX53 simulation framework developed within RD53 collaboration, is being used to guide vital choices for the design and optimization of the next generation ATLAS and CMS pixel chips and their critical serial powering circuit (shunt-LDO). Power consumption is studied at different stages of the design flow under different operating conditions. Significant effort is put into extensive investigations of dynamic power variations in relation with the decoupling seen by the powering network. Shunt-LDO simulations are also reported to prove the reliability at the system level.
Fusion of GEDI, ICESAT2 & NISAR data for above ground biomass mapping in Sonoma County, California
NASA Astrophysics Data System (ADS)
Duncanson, L.; Simard, M.; Thomas, N. M.; Neuenschwander, A. L.; Hancock, S.; Armston, J.; Dubayah, R.; Hofton, M. A.; Huang, W.; Tang, H.; Marselis, S.; Fatoyinbo, T.
2017-12-01
Several upcoming NASA missions will collect data sensitive to forest structure (GEDI, ICESAT-2 & NISAR). The LiDAR and SAR data collected by these missions will be used in coming years to map forest aboveground biomass at various resolutions. This research focuses on developing and testing multi-sensor data fusion approaches in advance of these missions. Here, we present the first case study of a CMS-16 grant with results from Sonoma County, California. We simulate lidar and SAR datasets from GEDI, ICESAT-2 and NISAR using airborne discrete return lidar and UAVSAR data, respectively. GEDI and ICESAT-2 signals are simulated from high point density discrete return lidar that was acquired over the entire county in 2014 through a previous CMS project (Dubayah & Hurtt, CMS-13). NISAR is simulated from L-band UAVSAR data collected in 2014. These simulations are empirically related to 300 field plots of aboveground biomass as well as a 30m biomass map produced from the 2014 airborne lidar data. We model biomass independently for each simulated mission dataset and then test two fusion methods for County-wide mapping 1) a pixel based approach and 2) an object oriented approach. In the pixel-based approach, GEDI and ICESAT-2 biomass models are calibrated over field plots and applied in orbital simulations for a 2-year period of the GEDI and ICESAT-2 missions. These simulated samples are then used to calibrate UAVSAR data to produce a 0.25 ha map. In the object oriented approach, the GEDI and ICESAT-2 data are identical to the pixel-based approach, but calibrate image objects of similar L-band backscatter rather than uniform pixels. The results of this research demonstrate the estimated ability for each of these three missions to independently map biomass in a temperate, high biomass system, as well as the potential improvement expected through combining mission datasets.
Kawahito, Shoji; Seo, Min-Woong
2016-11-06
This paper discusses the noise reduction effect of multiple-sampling-based signal readout circuits for implementing ultra-low-noise image sensors. The correlated multiple sampling (CMS) technique has recently become an important technology for high-gain column readout circuits in low-noise CMOS image sensors (CISs). This paper reveals how the column CMS circuits, together with a pixel having a high-conversion-gain charge detector and low-noise transistor, realizes deep sub-electron read noise levels based on the analysis of noise components in the signal readout chain from a pixel to the column analog-to-digital converter (ADC). The noise measurement results of experimental CISs are compared with the noise analysis and the effect of noise reduction to the sampling number is discussed at the deep sub-electron level. Images taken with three CMS gains of two, 16, and 128 show distinct advantage of image contrast for the gain of 128 (noise(median): 0.29 e - rms ) when compared with the CMS gain of two (2.4 e - rms ), or 16 (1.1 e - rms ).
Kawahito, Shoji; Seo, Min-Woong
2016-01-01
This paper discusses the noise reduction effect of multiple-sampling-based signal readout circuits for implementing ultra-low-noise image sensors. The correlated multiple sampling (CMS) technique has recently become an important technology for high-gain column readout circuits in low-noise CMOS image sensors (CISs). This paper reveals how the column CMS circuits, together with a pixel having a high-conversion-gain charge detector and low-noise transistor, realizes deep sub-electron read noise levels based on the analysis of noise components in the signal readout chain from a pixel to the column analog-to-digital converter (ADC). The noise measurement results of experimental CISs are compared with the noise analysis and the effect of noise reduction to the sampling number is discussed at the deep sub-electron level. Images taken with three CMS gains of two, 16, and 128 show distinct advantage of image contrast for the gain of 128 (noise(median): 0.29 e−rms) when compared with the CMS gain of two (2.4 e−rms), or 16 (1.1 e−rms). PMID:27827972
Signal-Conditioning Block of a 1 × 200 CMOS Detector Array for a Terahertz Real-Time Imaging System
Yang, Jong-Ryul; Lee, Woo-Jae; Han, Seong-Tae
2016-01-01
A signal conditioning block of a 1 × 200 Complementary Metal-Oxide-Semiconductor (CMOS) detector array is proposed to be employed with a real-time 0.2 THz imaging system for inspecting large areas. The plasmonic CMOS detector array whose pixel size including an integrated antenna is comparable to the wavelength of the THz wave for the imaging system, inevitably carries wide pixel-to-pixel variation. To make the variant outputs from the array uniform, the proposed signal conditioning block calibrates the responsivity of each pixel by controlling the gate bias of each detector and the voltage gain of the lock-in amplifiers in the block. The gate bias of each detector is modulated to 1 MHz to improve the signal-to-noise ratio of the imaging system via the electrical modulation by the conditioning block. In addition, direct current (DC) offsets of the detectors in the array are cancelled by initializing the output voltage level from the block. Real-time imaging using the proposed signal conditioning block is demonstrated by obtaining images at the rate of 19.2 frame-per-sec of an object moving on the conveyor belt with a scan width of 20 cm and a scan speed of 25 cm/s. PMID:26950128
Signal-Conditioning Block of a 1 × 200 CMOS Detector Array for a Terahertz Real-Time Imaging System.
Yang, Jong-Ryul; Lee, Woo-Jae; Han, Seong-Tae
2016-03-02
A signal conditioning block of a 1 × 200 Complementary Metal-Oxide-Semiconductor (CMOS) detector array is proposed to be employed with a real-time 0.2 THz imaging system for inspecting large areas. The plasmonic CMOS detector array whose pixel size including an integrated antenna is comparable to the wavelength of the THz wave for the imaging system, inevitably carries wide pixel-to-pixel variation. To make the variant outputs from the array uniform, the proposed signal conditioning block calibrates the responsivity of each pixel by controlling the gate bias of each detector and the voltage gain of the lock-in amplifiers in the block. The gate bias of each detector is modulated to 1 MHz to improve the signal-to-noise ratio of the imaging system via the electrical modulation by the conditioning block. In addition, direct current (DC) offsets of the detectors in the array are cancelled by initializing the output voltage level from the block. Real-time imaging using the proposed signal conditioning block is demonstrated by obtaining images at the rate of 19.2 frame-per-sec of an object moving on the conveyor belt with a scan width of 20 cm and a scan speed of 25 cm/s.
Theory of compressive modeling and simulation
NASA Astrophysics Data System (ADS)
Szu, Harold; Cha, Jae; Espinola, Richard L.; Krapels, Keith
2013-05-01
Modeling and Simulation (M&S) has been evolving along two general directions: (i) data-rich approach suffering the curse of dimensionality and (ii) equation-rich approach suffering computing power and turnaround time. We suggest a third approach. We call it (iii) compressive M&S (CM&S); because the basic Minimum Free-Helmholtz Energy (MFE) facilitating CM&S can reproduce and generalize Candes, Romberg, Tao & Donoho (CRT&D) Compressive Sensing (CS) paradigm as a linear Lagrange Constraint Neural network (LCNN) algorithm. CM&S based MFE can generalize LCNN to 2nd order as Nonlinear augmented LCNN. For example, during the sunset, we can avoid a reddish bias of sunlight illumination due to a long-range Rayleigh scattering over the horizon. With CM&S we can take instead of day camera, a night vision camera. We decomposed long wave infrared (LWIR) band with filter into 2 vector components (8~10μm and 10~12μm) and used LCNN to find pixel by pixel the map of Emissive-Equivalent Planck Radiation Sources (EPRS). Then, we up-shifted consistently, according to de-mixed sources map, to the sub-micron RGB color image. Moreover, the night vision imaging can also be down-shifted at Passive Millimeter Wave (PMMW) imaging, suffering less blur owing to dusty smokes scattering and enjoying apparent smoothness of surface reflectivity of man-made objects under the Rayleigh resolution. One loses three orders of magnitudes in the spatial Rayleigh resolution; but gains two orders of magnitude in the reflectivity, and gains another two orders in the propagation without obscuring smog . Since CM&S can generate missing data and hard to get dynamic transients, CM&S can reduce unnecessary measurements and their associated cost and computing in the sense of super-saving CS: measuring one & getting one's neighborhood free .
NASA Astrophysics Data System (ADS)
Ceresa, D.; Marchioro, A.; Kloukinas, K.; Kaplon, J.; Bialas, W.; Re, V.; Traversi, G.; Gaioni, L.; Ratti, L.
2014-11-01
The CMS tracker at HL-LHC is required to provide prompt information on particles with high transverse momentum to the central Level 1 trigger. For this purpose, the innermost part of the outer tracker is based on a combination of a pixelated sensor with a short strip sensor, the so-called Pixel-Strip module (PS). The readout of these sensors is carried out by distinct ASICs, the Strip Sensor ASIC (SSA), for the strip layer, and the Macro Pixel ASIC (MPA) for the pixel layer. The processing of the data directly on the front-end module represents a design challenge due to the large data volume (30720 pixels and 1920 strips per module) and the limited power budget. This is the reason why several studies have been carried out to find the best compromise between ASICs performance and power consumption. This paper describes the current status of the MPA ASIC development where the logic for generating prompt information on particles with high transverse momentum is implemented. An overview of the readout method is presented with particular attention on the cluster reduction, position encoding and momentum discrimination logic. Concerning the architectural studies, a software test bench capable of reading physics Monte-Carlo generated events has been developed and used to validate the MPA design and to evaluate the MPA performance. The MPA-Light is scheduled to be submitted for fabrication this year and will include the full analog functions and a part of the digital logic of the final version in order to qualify the chosen VLSI technology for the analog front-end, the module assembly and the low voltage digital supply.
Sensors for the CMS Forward Pixel Phase 1 Upgrade
NASA Astrophysics Data System (ADS)
Dilsiz, Kamuran; CMS Collaboration
2016-03-01
The next incarnation of the CMS forward pixel detector, to be installed during the year end extended technical stop 2016-17, will need to survive an integrated luminosity of 300 fb-1 with the inner radius of the active region of the disks decreasing from 6 to 4.5 cm. Based on the Run 1 experience and irradiation studies, the Phase 1 FPIX sensors will again be n-on-n DOFZ silicon, with parameters similar to those in the present run. We will review the design choices including a study during the prototyping phase to explore different p-stop layouts. Results from the quality assurance probing of the full production of sensor wafers will be described. The IV measurements are particularly impressive with current densities in range of 3-4 nA/cm2 at the full depletion voltage.
The INFN-FBK pixel R&D program for HL-LHC
NASA Astrophysics Data System (ADS)
Meschini, M.; Dalla Betta, G. F.; Boscardin, M.; Calderini, G.; Darbo, G.; Giacomini, G.; Messineo, A.; Ronchin, S.
2016-09-01
We report on the ATLAS and CMS joint research activity, which is aiming at the development of new, thin silicon pixel detectors for the Large Hadron Collider Phase-2 detector upgrades. This R&D is performed under special agreement between Istituto Nazionale di Fisica Nucleare and FBK foundation (Trento, Italy). New generations of 3D and planar pixel sensors with active edges are being developed in the R&D project, and will be fabricated at FBK. A first planar pixel batch, which was produced by the end of year 2014, will be described in this paper. First clean room measurement results on planar sensors obtained before and after neutron irradiation will be presented.
CO2 evaporative cooling: The future for tracking detector thermal management
NASA Astrophysics Data System (ADS)
Tropea, P.; Daguin, J.; Petagna, P.; Postema, H.; Verlaat, B.; Zwalinski, L.
2016-07-01
In the last few years, CO2 evaporative cooling has been one of the favourite technologies chosen for the thermal management of tracking detectors at LHC. ATLAS Insertable B-Layer and CMS Pixel phase 1 upgrade have adopted it and their systems are now operational or under commissioning. The CERN PH-DT team is now merging the lessons learnt on these two systems in order to prepare the design and construction of the cooling systems for the new Upstream Tracker and the Velo upgrade in LHCb, due by 2018. Meanwhile, the preliminary design of the ATLAS and CMS full tracker upgrades is started, and both concepts heavily rely on CO2 evaporative cooling. This paper highlights the performances of the systems now in operation and the challenges to overcome in order to scale them up to the requirements of the future generations of trackers. In particular, it focuses on the conceptual design of a new cooling system suited for the large phase 2 upgrade programmes, which will be validated with the construction of a common prototype in the next years.
Characterisation of irradiated thin silicon sensors for the CMS phase II pixel upgrade
Adam, W.; Bergauer, T.; Brondolin, E.; ...
2017-08-22
The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment’s silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equivalent fluence of up tomore » $$\\Phi _{eq} = 2 \\times 10^{16}$$ cm$$^{-2}$$ , and an ionising dose of $${\\approx } 5$$ MGy after an integrated luminosity of 3000 fb$$^{-1}$$ . Thin, planar silicon sensors are good candidates for this application, since the degradation of the signal produced by traversing particles is less severe than for thicker devices. Here in this article, the results obtained from the characterisation of 100 and 200 μm thick p-bulk pad diodes and strip sensors irradiated up to fluences of $$\\Phi _{eq} = 1.3 \\times 10^{16}$$ cm$$^{-2}$$ are shown.« less
NASA Astrophysics Data System (ADS)
Marconi, S.; Conti, E.; Christiansen, J.; Placidi, P.
2018-05-01
The operating conditions of the High Luminosity upgrade of the Large Hadron Collider are very demanding for the design of next generation hybrid pixel readout chips in terms of particle rate, radiation level and data bandwidth. To this purpose, the RD53 Collaboration has developed for the ATLAS and CMS experiments a dedicated simulation and verification environment using industry-consolidated tools and methodologies, such as SystemVerilog and the Universal Verification Methodology (UVM). This paper presents how the so-called VEPIX53 environment has first guided the design of digital architectures, optimized for processing and buffering very high particle rates, and secondly how it has been reused for the functional verification of the first large scale demonstrator chip designed by the collaboration, which has recently been submitted.
Pixel sensors with slim edges and small pitches for the CMS upgrades for HL-LHC
Vernieri, Caterina; Bolla, Gino; Rivera, Ryan; ...
2016-06-07
Here, planar n-in-n silicon detectors with small pitches and slim edges are being investigated for the innermost layers of tracking devices for the foreseen upgrades of the LHC experiments. Sensor prototypes compatible with the CMS readout, fabricated by Sintef, were tested in the laboratory and with a 120 GeV/c proton beam at the Fermilab test beam facility before and after irradiation with up to 2 × 10 15 neq/cm 2 fluence. Preliminary results of the data analysis are presented.
Tracking performance of a single-crystal and a polycrystalline diamond pixel-detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menasce, D.; et al.
2013-06-01
We present a comparative characterization of the performance of a single-crystal and a polycrystalline diamond pixel-detector employing the standard CMS pixel readout chips. Measurements were carried out at the Fermilab Test Beam Facility, FTBF, using protons of momentum 120 GeV/c tracked by a high-resolution pixel telescope. Particular attention was directed to the study of the charge-collection, the charge-sharing among adjacent pixels and the achievable position resolution. The performance of the single-crystal detector was excellent and comparable to the best available silicon pixel-detectors. The measured average detection-efficiency was near unity, ε = 0.99860±0.00006, and the position-resolution for shared hits was aboutmore » 6 μm. On the other hand, the performance of the polycrystalline detector was hampered by its lower charge collection distance and the readout chip threshold. A new readout chip, capable of operating at much lower threshold (around 1 ke $-$), would be required to fully exploit the potential performance of the polycrystalline diamond pixel-detector.« less
The CMS experiment at the CERN LHC
NASA Astrophysics Data System (ADS)
CMS Collaboration; Chatrchyan, S.; Hmayakyan, G.; Khachatryan, V.; Sirunyan, A. M.; Adam, W.; Bauer, T.; Bergauer, T.; Bergauer, H.; Dragicevic, M.; Erö, J.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Glaser, P.; Hartl, C.; Hoermann, N.; Hrubec, J.; Hänsel, S.; Jeitler, M.; Kastner, K.; Krammer, M.; Magrans de Abril, I.; Markytan, M.; Mikulec, I.; Neuherz, B.; Nöbauer, T.; Oberegger, M.; Padrta, M.; Pernicka, M.; Porth, P.; Rohringer, H.; Schmid, S.; Schreiner, T.; Stark, R.; Steininger, H.; Strauss, J.; Taurok, A.; Uhl, D.; Waltenberger, W.; Walzel, G.; Widl, E.; Wulz, C.-E.; Petrov, V.; Prosolovich, V.; Chekhovsky, V.; Dvornikov, O.; Emeliantchik, I.; Litomin, A.; Makarenko, V.; Marfin, I.; Mossolov, V.; Shumeiko, N.; Solin, A.; Stefanovitch, R.; Suarez Gonzalez, J.; Tikhonov, A.; Fedorov, A.; Korzhik, M.; Missevitch, O.; Zuyeuski, R.; Beaumont, W.; Cardaci, M.; DeLanghe, E.; DeWolf, E. A.; Delmeire, E.; Ochesanu, S.; Tasevsky, M.; Van Mechelen, P.; D'Hondt, J.; DeWeirdt, S.; Devroede, O.; Goorens, R.; Hannaert, S.; Heyninck, J.; Maes, J.; Mozer, M. U.; Tavernier, S.; Van Doninck, W.; Van Lancker, L.; Van Mulders, P.; Villella, I.; Wastiels, C.; Yu, C.; Bouhali, O.; Charaf, O.; Clerbaux, B.; DeHarenne, P.; DeLentdecker, G.; Dewulf, J. P.; Elgammal, S.; Gindroz, R.; Hammad, G. H.; Mahmoud, T.; Neukermans, L.; Pins, M.; Pins, R.; Rugovac, S.; Stefanescu, J.; Sundararajan, V.; Vander Velde, C.; Vanlaer, P.; Wickens, J.; Tytgat, M.; Assouak, S.; Bonnet, J. L.; Bruno, G.; Caudron, J.; DeCallatay, B.; DeFavereau DeJeneret, J.; DeVisscher, S.; Demin, P.; Favart, D.; Felix, C.; Florins, B.; Forton, E.; Giammanco, A.; Grégoire, G.; Jonckman, M.; Kcira, D.; Keutgen, T.; Lemaitre, V.; Michotte, D.; Militaru, O.; Ovyn, S.; Pierzchala, T.; Piotrzkowski, K.; Roberfroid, V.; Rouby, X.; Schul, N.; Van der Aa, O.; Beliy, N.; Daubie, E.; Herquet, P.; Alves, G.; Pol, M. E.; Souza, M. H. G.; Vaz, M.; DeJesus Damiao, D.; Oguri, V.; Santoro, A.; Sznajder, A.; DeMoraes Gregores, E.; Iope, R. L.; Novaes, S. F.; Tomei, T.; Anguelov, T.; Antchev, G.; Atanasov, I.; Damgov, J.; Darmenov, N.; Dimitrov, L.; Genchev, V.; Iaydjiev, P.; Marinov, A.; Piperov, S.; Stoykova, S.; Sultanov, G.; Trayanov, R.; Vankov, I.; Cheshkov, C.; Dimitrov, A.; Dyulendarova, M.; Glushkov, I.; Kozhuharov, V.; Litov, L.; Makariev, M.; Marinova, E.; Markov, S.; Mateev, M.; Nasteva, I.; Pavlov, B.; Petev, P.; Petkov, P.; Spassov, V.; Toteva, Z.; Velev, V.; Verguilov, V.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Jiang, C. H.; Liu, B.; Shen, X. Y.; Sun, H. S.; Tao, J.; Wang, J.; Yang, M.; Zhang, Z.; Zhao, W. R.; Zhuang, H. L.; Ban, Y.; Cai, J.; Ge, Y. C.; Liu, S.; Liu, H. T.; Liu, L.; Qian, S. J.; Wang, Q.; Xue, Z. H.; Yang, Z. C.; Ye, Y. L.; Ying, J.; Li, P. J.; Liao, J.; Xue, Z. L.; Yan, D. S.; Yuan, H.; Carrillo Montoya, C. A.; Sanabria, J. C.; Godinovic, N.; Puljak, I.; Soric, I.; Antunovic, Z.; Dzelalija, M.; Marasovic, K.; Brigljevic, V.; Kadija, K.; Morovic, S.; Fereos, R.; Nicolaou, C.; Papadakis, A.; Ptochos, F.; Razis, P. A.; Tsiakkouri, D.; Zinonos, Z.; Hektor, A.; Kadastik, M.; Kannike, K.; Lippmaa, E.; Müntel, M.; Raidal, M.; Rebane, L.; Aarnio, P. A.; Anttila, E.; Banzuzi, K.; Bulteau, P.; Czellar, S.; Eiden, N.; Eklund, C.; Engstrom, P.; Heikkinen, A.; Honkanen, A.; Härkönen, J.; Karimäki, V.; Katajisto, H. M.; Kinnunen, R.; Klem, J.; Kortesmaa, J.; Kotamäki, M.; Kuronen, A.; Lampén, T.; Lassila-Perini, K.; Lefébure, V.; Lehti, S.; Lindén, T.; Luukka, P. R.; Michal, S.; Moura Brigido, F.; Mäenpää, T.; Nyman, T.; Nystén, J.; Pietarinen, E.; Skog, K.; Tammi, K.; Tuominen, E.; Tuominiemi, J.; Ungaro, D.; Vanhala, T. P.; Wendland, L.; Williams, C.; Iskanius, M.; Korpela, A.; Polese, G.; Tuuva, T.; Bassompierre, G.; Bazan, A.; David, P. Y.; Ditta, J.; Drobychev, G.; Fouque, N.; Guillaud, J. P.; Hermel, V.; Karneyeu, A.; LeFlour, T.; Lieunard, S.; Maire, M.; Mendiburu, P.; Nedelec, P.; Peigneux, J. P.; Schneegans, M.; Sillou, D.; Vialle, J. P.; Anfreville, M.; Bard, J. P.; Besson, P.; Bougamont, E.; Boyer, M.; Bredy, P.; Chipaux, R.; Dejardin, M.; Denegri, D.; Descamps, J.; Fabbro, B.; Faure, J. L.; Ganjour, S.; Gentit, F. X.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Jeanney, C.; Kircher, F.; Lemaire, M. C.; Lemoigne, Y.; Levesy, B.; Locci, E.; Lottin, J. P.; Mandjavidze, I.; Mur, M.; Pansart, J. P.; Payn, A.; Rander, J.; Reymond, J. M.; Rolquin, J.; Rondeaux, F.; Rosowsky, A.; Rousse, J. Y. A.; Sun, Z. H.; Tartas, J.; Van Lysebetten, A.; Venault, P.; Verrecchia, P.; Anduze, M.; Badier, J.; Baffioni, S.; Bercher, M.; Bernet, C.; Berthon, U.; Bourotte, J.; Busata, A.; Busson, P.; Cerutti, M.; Chamont, D.; Charlot, C.; Collard, C.; Debraine, A.; Decotigny, D.; Dobrzynski, L.; Ferreira, O.; Geerebaert, Y.; Gilly, J.; Gregory, C.; Guevara Riveros, L.; Haguenauer, M.; Karar, A.; Koblitz, B.; Lecouturier, D.; Mathieu, A.; Milleret, G.; Miné, P.; Paganini, P.; Poilleux, P.; Pukhaeva, N.; Regnault, N.; Romanteau, T.; Semeniouk, I.; Sirois, Y.; Thiebaux, C.; Vanel, J. C.; Zabi, A.; Agram, J. L.; Albert, A.; Anckenmann, L.; Andrea, J.; Anstotz, F.; Bergdolt, A. M.; Berst, J. D.; Blaes, R.; Bloch, D.; Brom, J. M.; Cailleret, J.; Charles, F.; Christophel, E.; Claus, G.; Coffin, J.; Colledani, C.; Croix, J.; Dangelser, E.; Dick, N.; Didierjean, F.; Drouhin, F.; Dulinski, W.; Ernenwein, J. P.; Fang, R.; Fontaine, J. C.; Gaudiot, G.; Geist, W.; Gelé, D.; Goeltzenlichter, T.; Goerlach, U.; Graehling, P.; Gross, L.; Hu, C. Guo; Helleboid, J. M.; Henkes, T.; Hoffer, M.; Hoffmann, C.; Hosselet, J.; Houchu, L.; Hu, Y.; Huss, D.; Illinger, C.; Jeanneau, F.; Juillot, P.; Kachelhoffer, T.; Kapp, M. R.; Kettunen, H.; Lakehal Ayat, L.; LeBihan, A. C.; Lounis, A.; Maazouzi, C.; Mack, V.; Majewski, P.; Mangeol, D.; Michel, J.; Moreau, S.; Olivetto, C.; Pallarès, A.; Patois, Y.; Pralavorio, P.; Racca, C.; Riahi, Y.; Ripp-Baudot, I.; Schmitt, P.; Schunck, J. P.; Schuster, G.; Schwaller, B.; Sigward, M. H.; Sohler, J. L.; Speck, J.; Strub, R.; Todorov, T.; Turchetta, R.; Van Hove, P.; Vintache, D.; Zghiche, A.; Ageron, M.; Augustin, J. E.; Baty, C.; Baulieu, G.; Bedjidian, M.; Blaha, J.; Bonnevaux, A.; Boudoul, G.; Brunet, P.; Chabanat, E.; Chabert, E. C.; Chierici, R.; Chorowicz, V.; Combaret, C.; Contardo, D.; Della Negra, R.; Depasse, P.; Drapier, O.; Dupanloup, M.; Dupasquier, T.; El Mamouni, H.; Estre, N.; Fay, J.; Gascon, S.; Giraud, N.; Girerd, C.; Guillot, G.; Haroutunian, R.; Ille, B.; Lethuillier, M.; Lumb, N.; Martin, C.; Mathez, H.; Maurelli, G.; Muanza, S.; Pangaud, P.; Perries, S.; Ravat, O.; Schibler, E.; Schirra, F.; Smadja, G.; Tissot, S.; Trocme, B.; Vanzetto, S.; Walder, J. P.; Bagaturia, Y.; Mjavia, D.; Mzhavia, A.; Tsamalaidze, Z.; Roinishvili, V.; Adolphi, R.; Anagnostou, G.; Brauer, R.; Braunschweig, W.; Esser, H.; Feld, L.; Karpinski, W.; Khomich, A.; Klein, K.; Kukulies, C.; Lübelsmeyer, K.; Olzem, J.; Ostaptchouk, A.; Pandoulas, D.; Pierschel, G.; Raupach, F.; Schael, S.; Schultz von Dratzig, A.; Schwering, G.; Siedling, R.; Thomas, M.; Weber, M.; Wittmer, B.; Wlochal, M.; Adamczyk, F.; Adolf, A.; Altenhöfer, G.; Bechstein, S.; Bethke, S.; Biallass, P.; Biebel, O.; Bontenackels, M.; Bosseler, K.; Böhm, A.; Erdmann, M.; Faissner, H.; Fehr, B.; Fesefeldt, H.; Fetchenhauer, G.; Frangenheim, J.; Frohn, J. H.; Grooten, J.; Hebbeker, T.; Hermann, S.; Hermens, E.; Hilgers, G.; Hoepfner, K.; Hof, C.; Jacobi, E.; Kappler, S.; Kirsch, M.; Kreuzer, P.; Kupper, R.; Lampe, H. R.; Lanske, D.; Mameghani, R.; Meyer, A.; Meyer, S.; Moers, T.; Müller, E.; Pahlke, R.; Philipps, B.; Rein, D.; Reithler, H.; Reuter, W.; Rütten, P.; Schulz, S.; Schwarthoff, H.; Sobek, W.; Sowa, M.; Stapelberg, T.; Szczesny, H.; Teykal, H.; Teyssier, D.; Tomme, H.; Tomme, W.; Tonutti, M.; Tsigenov, O.; Tutas, J.; Vandenhirtz, J.; Wagner, H.; Wegner, M.; Zeidler, C.; Beissel, F.; Davids, M.; Duda, M.; Flügge, G.; Giffels, M.; Hermanns, T.; Heydhausen, D.; Kalinin, S.; Kasselmann, S.; Kaussen, G.; Kress, T.; Linn, A.; Nowack, A.; Perchalla, L.; Poettgens, M.; Pooth, O.; Sauerland, P.; Stahl, A.; Tornier, D.; Zoeller, M. H.; Behrens, U.; Borras, K.; Flossdorf, A.; Hatton, D.; Hegner, B.; Kasemann, M.; Mankel, R.; Meyer, A.; Mnich, J.; Rosemann, C.; Youngman, C.; Zeuner, W. D.; Bechtel, F.; Buhmann, P.; Butz, E.; Flucke, G.; Hamdorf, R. H.; Holm, U.; Klanner, R.; Pein, U.; Schirm, N.; Schleper, P.; Steinbrück, G.; Van Staa, R.; Wolf, R.; Atz, B.; Barvich, T.; Blüm, P.; Boegelspacher, F.; Bol, H.; Chen, Z. Y.; Chowdhury, S.; DeBoer, W.; Dehm, P.; Dirkes, G.; Fahrer, M.; Felzmann, U.; Frey, M.; Furgeri, A.; Gregoriev, E.; Hartmann, F.; Hauler, F.; Heier, S.; Kärcher, K.; Ledermann, B.; Mueller, S.; Müller, Th; Neuberger, D.; Piasecki, C.; Quast, G.; Rabbertz, K.; Sabellek, A.; Scheurer, A.; Schilling, F. P.; Simonis, H. J.; Skiba, A.; Steck, P.; Theel, A.; Thümmel, W. H.; Trunov, A.; Vest, A.; Weiler, T.; Weiser, C.; Weseler, S.; Zhukov, V.; Barone, M.; Daskalakis, G.; Dimitriou, N.; Fanourakis, G.; Filippidis, C.; Geralis, T.; Kalfas, C.; Karafasoulis, K.; Koimas, A.; Kyriakis, A.; Kyriazopoulou, S.; Loukas, D.; Markou, A.; Markou, C.; Mastroyiannopoulos, N.; Mavrommatis, C.; Mousa, J.; Papadakis, I.; Petrakou, E.; Siotis, I.; Theofilatos, K.; Tzamarias, S.; Vayaki, A.; Vermisoglou, G.; Zachariadou, A.; Gouskos, L.; Karapostoli, G.; Katsas, P.; Panagiotou, A.; Papadimitropoulos, C.; Aslanoglou, X.; Evangelou, I.; Kokkas, P.; Manthos, N.; Papadopoulos, I.; Triantis, F. A.; Bencze, G.; Boldizsar, L.; Debreczeni, G.; Hajdu, C.; Hidas, P.; Horvath, D.; Kovesarki, P.; Laszlo, A.; Odor, G.; Patay, G.; Sikler, F.; Veres, G.; Vesztergombi, G.; Zalan, P.; Fenyvesi, A.; Imrek, J.; Molnar, J.; Novak, D.; Palinkas, J.; Szekely, G.; Beni, N.; Kapusi, A.; Marian, G.; Radics, B.; Raics, P.; Szabo, Z.; Szillasi, Z.; Trocsanyi, Z. L.; Zilizi, G.; Bawa, H. S.; Beri, S. B.; Bhandari, V.; Bhatnagar, V.; Kaur, M.; Kohli, J. M.; Kumar, A.; Singh, B.; Singh, J. B.; Arora, S.; Bhattacharya, S.; Chatterji, S.; Chauhan, S.; Choudhary, B. C.; Gupta, P.; Jha, M.; Ranjan, K.; Shivpuri, R. K.; Srivastava, A. K.; Choudhury, R. K.; Dutta, D.; Ghodgaonkar, M.; Kailas, S.; Kataria, S. K.; Mohanty, A. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Banerjee, Sunanda; Bose, S.; Chendvankar, S.; Deshpande, P. V.; Guchait, M.; Gurtu, A.; Maity, M.; Majumder, G.; Mazumdar, K.; Nayak, A.; Patil, M. R.; Sharma, S.; Sudhakar, K.; Acharya, B. S.; Banerjee, Sudeshna; Bheesette, S.; Dugad, S.; Kalmani, S. D.; Lakkireddi, V. R.; Mondal, N. K.; Panyam, N.; Verma, P.; Arfaei, H.; Hashemi, M.; Najafabadi, M. Mohammadi; Moshaii, A.; Paktinat Mehdiabadi, S.; Felcini, M.; Grunewald, M.; Abadjiev, K.; Abbrescia, M.; Barbone, L.; Cariola, P.; Chiumarulo, F.; Clemente, A.; Colaleo, A.; Creanza, D.; DeFilippis, N.; DePalma, M.; DeRobertis, G.; Donvito, G.; Ferorelli, R.; Fiore, L.; Franco, M.; Giordano, D.; Guida, R.; Iaselli, G.; Lacalamita, N.; Loddo, F.; Maggi, G.; Maggi, M.; Manna, N.; Marangelli, B.; Mennea, M. S.; My, S.; Natali, S.; Nuzzo, S.; Papagni, G.; Pinto, C.; Pompili, A.; Pugliese, G.; Ranieri, A.; Romano, F.; Roselli, G.; Sala, G.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Trentadue, R.; Tupputi, S.; Zito, G.; Abbiendi, G.; Bacchi, W.; Battilana, C.; Benvenuti, A. C.; Boldini, M.; Bonacorsi, D.; Braibant-Giacomelli, S.; Cafaro, V. D.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Ciocca, C.; Codispoti, G.; Cuffiani, M.; D'Antone, I.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Finelli, S.; Giacomelli, P.; Giordano, V.; Giunta, M.; Grandi, C.; Guerzoni, M.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Odorici, F.; Paolucci, A.; Pellegrini, G.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Torromeo, G.; Travaglini, R.; Veronese, G. P.; Albergo, S.; Chiorboli, M.; Costa, S.; Galanti, M.; Gatto Rotondo, G.; Giudice, N.; Guardone, N.; Noto, F.; Potenza, R.; Saizu, M. A.; Salemi, G.; Sutera, C.; Tricomi, A.; Tuve, C.; Bellucci, L.; Brianzi, M.; Broccolo, G.; Catacchini, E.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Frosali, S.; Genta, C.; Landi, G.; Lenzi, P.; Macchiolo, A.; Maletta, F.; Manolescu, F.; Marchettini, C.; Masetti, L.; Mersi, S.; Meschini, M.; Minelli, C.; Paoletti, S.; Parrini, G.; Scarlini, E.; Sguazzoni, G.; Benussi, L.; Bertani, M.; Bianco, S.; Caponero, M.; Colonna, D.; Daniello, L.; Fabbri, F.; Felli, F.; Giardoni, M.; La Monaca, A.; Ortenzi, B.; Pallotta, M.; Paolozzi, A.; Paris, C.; Passamonti, L.; Pierluigi, D.; Ponzio, B.; Pucci, C.; Russo, A.; Saviano, G.; Fabbricatore, P.; Farinon, S.; Greco, M.; Musenich, R.; Badoer, S.; Berti, L.; Biasotto, M.; Fantinel, S.; Frizziero, E.; Gastaldi, U.; Gulmini, M.; Lelli, F.; Maron, G.; Squizzato, S.; Toniolo, N.; Traldi, S.; Banfi, S.; Bertoni, R.; Bonesini, M.; Carbone, L.; Cerati, G. B.; Chignoli, F.; D'Angelo, P.; DeMin, A.; Dini, P.; Farina, F. M.; Ferri, F.; Govoni, P.; Magni, S.; Malberti, M.; Malvezzi, S.; Mazza, R.; Menasce, D.; Miccio, V.; Moroni, L.; Negri, P.; Paganoni, M.; Pedrini, D.; Pullia, A.; Ragazzi, S.; Redaelli, N.; Rovere, M.; Sala, L.; Sala, S.; Salerno, R.; Tabarelli de Fatis, T.; Tancini, V.; Taroni, S.; Boiano, A.; Cassese, F.; Cassese, C.; Cimmino, A.; D'Aquino, B.; Lista, L.; Lomidze, D.; Noli, P.; Paolucci, P.; Passeggio, G.; Piccolo, D.; Roscilli, L.; Sciacca, C.; Vanzanella, A.; Azzi, P.; Bacchetta, N.; Barcellan, L.; Bellato, M.; Benettoni, M.; Bisello, D.; Borsato, E.; Candelori, A.; Carlin, R.; Castellani, L.; Checchia, P.; Ciano, L.; Colombo, A.; Conti, E.; Da Rold, M.; Dal Corso, F.; DeGiorgi, M.; DeMattia, M.; Dorigo, T.; Dosselli, U.; Fanin, C.; Galet, G.; Gasparini, F.; Gasparini, U.; Giraldo, A.; Giubilato, P.; Gonella, F.; Gresele, A.; Griggio, A.; Guaita, P.; Kaminskiy, A.; Karaevskii, S.; Khomenkov, V.; Kostylev, D.; Lacaprara, S.; Lazzizzera, I.; Lippi, I.; Loreti, M.; Margoni, M.; Martinelli, R.; Mattiazzo, S.; Mazzucato, M.; Meneguzzo, A. T.; Modenese, L.; Montecassiano, F.; Neviani, A.; Nigro, M.; Paccagnella, A.; Pantano, D.; Parenti, A.; Passaseo, M.; Pedrotta, R.; Pegoraro, M.; Rampazzo, G.; Reznikov, S.; Ronchese, P.; Sancho Daponte, A.; Sartori, P.; Stavitskiy, I.; Tessaro, M.; Torassa, E.; Triossi, A.; Vanini, S.; Ventura, S.; Ventura, L.; Verlato, M.; Zago, M.; Zatti, F.; Zotto, P.; Zumerle, G.; Baesso, P.; Belli, G.; Berzano, U.; Bricola, S.; Grelli, A.; Musitelli, G.; Nardò, R.; Necchi, M. M.; Pagano, D.; Ratti, S. P.; Riccardi, C.; Torre, P.; Vicini, A.; Vitulo, P.; Viviani, C.; Aisa, D.; Aisa, S.; Ambroglini, F.; Angarano, M. M.; Babucci, E.; Benedetti, D.; Biasini, M.; Bilei, G. M.; Bizzaglia, S.; Brunetti, M. T.; Caponeri, B.; Checcucci, B.; Covarelli, R.; Dinu, N.; Fanò, L.; Farnesini, L.; Giorgi, M.; Lariccia, P.; Mantovani, G.; Moscatelli, F.; Passeri, D.; Piluso, A.; Placidi, P.; Postolache, V.; Santinelli, R.; Santocchia, A.; Servoli, L.; Spiga, D.; Azzurri, P.; Bagliesi, G.; Balestri, G.; Basti, A.; Bellazzini, R.; Benucci, L.; Bernardini, J.; Berretta, L.; Bianucci, S.; Boccali, T.; Bocci, A.; Borrello, L.; Bosi, F.; Bracci, F.; Brez, A.; Calzolari, F.; Castaldi, R.; Cazzola, U.; Ceccanti, M.; Cecchi, R.; Cerri, C.; Cucoanes, A. S.; Dell'Orso, R.; Dobur, D.; Dutta, S.; Fiori, F.; Foà, L.; Gaggelli, A.; Gennai, S.; Giassi, A.; Giusti, S.; Kartashov, D.; Kraan, A.; Latronico, L.; Ligabue, F.; Linari, S.; Lomtadze, T.; Lungu, G. A.; Magazzu, G.; Mammini, P.; Mariani, F.; Martinelli, G.; Massa, M.; Messineo, A.; Moggi, A.; Palla, F.; Palmonari, F.; Petragnani, G.; Petrucciani, G.; Profeti, A.; Raffaelli, F.; Rizzi, D.; Sanguinetti, G.; Sarkar, S.; Segneri, G.; Sentenac, D.; Serban, A. T.; Slav, A.; Spagnolo, P.; Spandre, G.; Tenchini, R.; Tolaini, S.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Vos, M.; Zaccarelli, L.; Baccaro, S.; Barone, L.; Bartoloni, A.; Borgia, B.; Capradossi, G.; Cavallari, F.; Cecilia, A.; D'Angelo, D.; Dafinei, I.; DelRe, D.; Di Marco, E.; Diemoz, M.; Ferrara, G.; Gargiulo, C.; Guerra, S.; Iannone, M.; Longo, E.; Montecchi, M.; Nuccetelli, M.; Organtini, G.; Palma, A.; Paramatti, R.; Pellegrino, F.; Rahatlou, S.; Rovelli, C.; Safai Tehrani, F.; Zullo, A.; Alampi, G.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bellan, R.; Benotto, F.; Biino, C.; Bolognesi, S.; Borgia, M. A.; Botta, C.; Brasolin, A.; Cartiglia, N.; Castello, R.; Cerminara, G.; Cirio, R.; Cordero, M.; Costa, M.; Dattola, D.; Daudo, F.; Dellacasa, G.; Demaria, N.; Dughera, G.; Dumitrache, F.; Farano, R.; Ferrero, G.; Filoni, E.; Kostyleva, G.; Larsen, H. E.; Mariotti, C.; Marone, M.; Maselli, S.; Menichetti, E.; Mereu, P.; Migliore, E.; Mila, G.; Monaco, V.; Musich, M.; Nervo, M.; Obertino, M. M.; Panero, R.; Parussa, A.; Pastrone, N.; Peroni, C.; Petrillo, G.; Romero, A.; Ruspa, M.; Sacchi, R.; Scalise, M.; Solano, A.; Staiano, A.; Trapani, P. P.; Trocino, D.; Vaniev, V.; Vilela Pereira, A.; Zampieri, A.; Belforte, S.; Cossutti, F.; Della Ricca, G.; Gobbo, B.; Kavka, C.; Penzo, A.; Kim, Y. E.; Nam, S. K.; Kim, D. H.; Kim, G. N.; Kim, J. C.; Kong, D. J.; Ro, S. R.; Son, D. C.; Park, S. Y.; Kim, Y. J.; Kim, J. Y.; Lim, I. T.; Pac, M. Y.; Lee, S. J.; Jung, S. Y.; Rhee, J. T.; Ahn, S. H.; Hong, B. S.; Jeng, Y. K.; Kang, M. H.; Kim, H. C.; Kim, J. H.; Kim, T. J.; Lee, K. S.; Lim, J. K.; Moon, D. H.; Park, I. C.; Park, S. K.; Ryu, M. S.; Sim, K.-S.; Son, K. J.; Hong, S. J.; Choi, Y. I.; Castilla Valdez, H.; Sanchez Hernandez, A.; Carrillo Moreno, S.; Morelos Pineda, A.; Aerts, A.; Van der Stok, P.; Weffers, H.; Allfrey, P.; Gray, R. N. C.; Hashimoto, M.; Krofcheck, D.; Bell, A. J.; Bernardino Rodrigues, N.; Butler, P. H.; Churchwell, S.; Knegjens, R.; Whitehead, S.; Williams, J. C.; Aftab, Z.; Ahmad, U.; Ahmed, I.; Ahmed, W.; Asghar, M. I.; Asghar, S.; Dad, G.; Hafeez, M.; Hoorani, H. R.; Hussain, I.; Hussain, N.; Iftikhar, M.; Khan, M. S.; Mehmood, K.; Osman, A.; Shahzad, H.; Zafar, A. R.; Ali, A.; Bashir, A.; Jan, A. M.; Kamal, A.; Khan, F.; Saeed, M.; Tanwir, S.; Zafar, M. A.; Blocki, J.; Cyz, A.; Gladysz-Dziadus, E.; Mikocki, S.; Rybczynski, M.; Turnau, J.; Wlodarczyk, Z.; Zychowski, P.; Bunkowski, K.; Cwiok, M.; Czyrkowski, H.; Dabrowski, R.; Dominik, W.; Doroba, K.; Kalinowski, A.; Kierzkowski, K.; Konecki, M.; Krolikowski, J.; Kudla, I. M.; Pietrusinski, M.; Pozniak, K.; Zabolotny, W.; Zych, P.; Gokieli, R.; Goscilo, L.; Górski, M.; Nawrocki, K.; Traczyk, P.; Wrochna, G.; Zalewski, P.; Pozniak, K. T.; Romaniuk, R.; Zabolotny, W. M.; Alemany-Fernandez, R.; Almeida, C.; Almeida, N.; Araujo Vila Verde, A. S.; Barata Monteiro, T.; Bluj, M.; Da Mota Silva, S.; Tinoco Mendes, A. David; Freitas Ferreira, M.; Gallinaro, M.; Husejko, M.; Jain, A.; Kazana, M.; Musella, P.; Nobrega, R.; Rasteiro Da Silva, J.; Ribeiro, P. Q.; Santos, M.; Silva, P.; Silva, S.; Teixeira, I.; Teixeira, J. P.; Varela, J.; Varner, G.; Vaz Cardoso, N.; Altsybeev, I.; Babich, K.; Belkov, A.; Belotelov, I.; Bunin, P.; Chesnevskaya, S.; Elsha, V.; Ershov, Y.; Filozova, I.; Finger, M.; Finger, M., Jr.; Golunov, A.; Golutvin, I.; Gorbounov, N.; Gramenitski, I.; Kalagin, V.; Kamenev, A.; Karjavin, V.; Khabarov, S.; Khabarov, V.; Kiryushin, Y.; Konoplyanikov, V.; Korenkov, V.; Kozlov, G.; Kurenkov, A.; Lanev, A.; Lysiakov, V.; Malakhov, A.; Melnitchenko, I.; Mitsyn, V. V.; Moisenz, K.; Moisenz, P.; Movchan, S.; Nikonov, E.; Oleynik, D.; Palichik, V.; Perelygin, V.; Petrosyan, A.; Rogalev, E.; Samsonov, V.; Savina, M.; Semenov, R.; Sergeev, S.; Shmatov, S.; Shulha, S.; Smirnov, V.; Smolin, D.; Tcheremoukhine, A.; Teryaev, O.; Tikhonenko, E.; Urkinbaev, A.; Vasil'ev, S.; Vishnevskiy, A.; Volodko, A.; Zamiatin, N.; Zarubin, A.; Zarubin, P.; Zubarev, E.; Bondar, N.; Gavrikov, Y.; Golovtsov, V.; Ivanov, Y.; Kim, V.; Kozlov, V.; Lebedev, V.; Makarenkov, G.; Moroz, F.; Neustroev, P.; Obrant, G.; Orishchin, E.; Petrunin, A.; Shcheglov, Y.; Shchetkovskiy, A.; Sknar, V.; Skorobogatov, V.; Smirnov, I.; Sulimov, V.; Tarakanov, V.; Uvarov, L.; Vavilov, S.; Velichko, G.; Volkov, S.; Vorobyev, A.; Chmelev, D.; Druzhkin, D.; Ivanov, A.; Kudinov, V.; Logatchev, O.; Onishchenko, S.; Orlov, A.; Sakharov, V.; Smetannikov, V.; Tikhomirov, A.; Zavodthikov, S.; Andreev, Yu; Anisimov, A.; Duk, V.; Gninenko, S.; Golubev, N.; Gorbunov, D.; Kirsanov, M.; Krasnikov, N.; Matveev, V.; Pashenkov, A.; Pastsyak, A.; Postoev, V. E.; Sadovski, A.; Skassyrskaia, A.; Solovey, Alexander; Solovey, Anatoly; Soloviev, D.; Toropin, A.; Troitsky, S.; Alekhin, A.; Baldov, A.; Epshteyn, V.; Gavrilov, V.; Ilina, N.; Kaftanov, V.; Karpishin, V.; Kiselevich, I.; Kolosov, V.; Kossov, M.; Krokhotin, A.; Kuleshov, S.; Oulianov, A.; Pozdnyakov, A.; Safronov, G.; Semenov, S.; Stepanov, N.; Stolin, V.; Vlasov, E.; Zaytsev, V.; Boos, E.; Dubinin, M.; Dudko, L.; Ershov, A.; Eyyubova, G.; Gribushin, A.; Ilyin, V.; Klyukhin, V.; Kodolova, O.; Kruglov, N. A.; Kryukov, A.; Lokhtin, I.; Malinina, L.; Mikhaylin, V.; Petrushanko, S.; Sarycheva, L.; Savrin, V.; Shamardin, L.; Sherstnev, A.; Snigirev, A.; Teplov, K.; Vardanyan, I.; Fomenko, A. M.; Konovalova, N.; Kozlov, V.; Lebedev, A. I.; Lvova, N.; Rusakov, S. V.; Terkulov, A.; Abramov, V.; Akimenko, S.; Artamonov, A.; Ashimova, A.; Azhgirey, I.; Bitioukov, S.; Chikilev, O.; Datsko, K.; Filine, A.; Godizov, A.; Goncharov, P.; Grishin, V.; Inyakin, A.; Kachanov, V.; Kalinin, A.; Khmelnikov, A.; Konstantinov, D.; Korablev, A.; Krychkine, V.; Krinitsyn, A.; Levine, A.; Lobov, I.; Lukanin, V.; Mel'nik, Y.; Molchanov, V.; Petrov, V.; Petukhov, V.; Pikalov, V.; Ryazanov, A.; Ryutin, R.; Shelikhov, V.; Skvortsov, V.; Slabospitsky, S.; Sobol, A.; Sytine, A.; Talov, V.; Tourtchanovitch, L.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Zelepoukine, S.; Lukyanov, V.; Mamaeva, G.; Prilutskaya, Z.; Rumyantsev, I.; Sokha, S.; Tataurschikov, S.; Vasilyev, I.; Adzic, P.; Anicin, I.; Djordjevic, M.; Jovanovic, D.; Maletic, D.; Puzovic, J.; Smiljkovic, N.; Aguayo Navarrete, E.; Aguilar-Benitez, M.; Ahijado Munoz, J.; Alarcon Vega, J. M.; Alberdi, J.; Alcaraz Maestre, J.; Aldaya Martin, M.; Arce, P.; Barcala, J. M.; Berdugo, J.; Blanco Ramos, C. L.; Burgos Lazaro, C.; Caballero Bejar, J.; Calvo, E.; Cerrada, M.; Chamizo Llatas, M.; Chercoles Catalán, J. J.; Colino, N.; Daniel, M.; DeLa Cruz, B.; Delgado Peris, A.; Fernandez Bedoya, C.; Ferrando, A.; Fouz, M. C.; Francia Ferrero, D.; Garcia Romero, J.; Garcia-Abia, P.; Gonzalez Lopez, O.; Hernandez, J. M.; Josa, M. I.; Marin, J.; Merino, G.; Molinero, A.; Navarrete, J. J.; Oller, J. C.; Puerta Pelayo, J.; Puras Sanchez, J. C.; Ramirez, J.; Romero, L.; Villanueva Munoz, C.; Willmott, C.; Yuste, C.; Albajar, C.; de Trocóniz, J. F.; Jimenez, I.; Macias, R.; Teixeira, R. F.; Cuevas, J.; Fernández Menéndez, J.; Gonzalez Caballero, I.; Lopez-Garcia, J.; Naves Sordo, H.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Cano Fernandez, D.; Diaz Merino, I.; Duarte Campderros, J.; Fernandez, M.; Fernandez Menendez, J.; Figueroa, C.; Garcia Moral, L. A.; Gomez, G.; Gomez Casademunt, F.; Gonzalez Sanchez, J.; Gonzalez Suarez, R.; Jorda, C.; Lobelle Pardo, P.; Lopez Garcia, A.; Lopez Virto, A.; Marco, J.; Marco, R.; Martinez Rivero, C.; Martinez Ruiz del Arbol, P.; Matorras, F.; Orviz Fernandez, P.; Patino Revuelta, A.; Rodrigo, T.; Rodriguez Gonzalez, D.; Ruiz Jimeno, A.; Scodellaro, L.; Sobron Sanudo, M.; Vila, I.; Vilar Cortabitarte, R.; Barbero, M.; Goldin, D.; Henrich, B.; Tauscher, L.; Vlachos, S.; Wadhwa, M.; Abbaneo, D.; Abbas, S. M.; Ahmed, I.; Akhtar, S.; Akhtar, M. I.; Albert, E.; Alidra, M.; Ashby, S.; Aspell, P.; Auffray, E.; Baillon, P.; Ball, A.; Bally, S. L.; Bangert, N.; Barillère, R.; Barney, D.; Beauceron, S.; Beaudette, F.; Benelli, G.; Benetta, R.; Benichou, J. L.; Bialas, W.; Bjorkebo, A.; Blechschmidt, D.; Bloch, C.; Bloch, P.; Bonacini, S.; Bos, J.; Bosteels, M.; Boyer, V.; Branson, A.; Breuker, H.; Bruneliere, R.; Buchmuller, O.; Campi, D.; Camporesi, T.; Caner, A.; Cano, E.; Carrone, E.; Cattai, A.; Chatelain, J. P.; Chauvey, M.; Christiansen, T.; Ciganek, M.; Cittolin, S.; Cogan, J.; Conde Garcia, A.; Cornet, H.; Corrin, E.; Corvo, M.; Cucciarelli, S.; Curé, B.; D'Enterria, D.; DeRoeck, A.; de Visser, T.; Delaere, C.; Delattre, M.; Deldicque, C.; Delikaris, D.; Deyrail, D.; Di Vincenzo, S.; Domeniconi, A.; Dos Santos, S.; Duthion, G.; Edera, L. M.; Elliott-Peisert, A.; Eppard, M.; Fanzago, F.; Favre, M.; Foeth, H.; Folch, R.; Frank, N.; Fratianni, S.; Freire, M. A.; Frey, A.; Fucci, A.; Funk, W.; Gaddi, A.; Gagliardi, F.; Gastal, M.; Gateau, M.; Gayde, J. C.; Gerwig, H.; Ghezzi, A.; Gigi, D.; Gill, K.; Giolo-Nicollerat, A. S.; Girod, J. P.; Glege, F.; Glessing, W.; Gomez-Reino Garrido, R.; Goudard, R.; Grabit, R.; Grillet, J. P.; Gutierrez Llamas, P.; Gutierrez Mlot, E.; Gutleber, J.; Hall-wilton, R.; Hammarstrom, R.; Hansen, M.; Harvey, J.; Hervé, A.; Hill, J.; Hoffmann, H. F.; Holzner, A.; Honma, A.; Hufnagel, D.; Huhtinen, M.; Ilie, S. D.; Innocente, V.; Jank, W.; Janot, P.; Jarron, P.; Jeanrenaud, M.; Jouvel, P.; Kerkach, R.; Kloukinas, K.; Kottelat, L. J.; Labbé, J. C.; Lacroix, D.; Lagrue, X.; Lasseur, C.; Laure, E.; Laurens, J. F.; Lazeyras, P.; LeGoff, J. M.; Lebeau, M.; Lecoq, P.; Lemeilleur, F.; Lenzi, M.; Leonardo, N.; Leonidopoulos, C.; Letheren, M.; Liendl, M.; Limia-Conde, F.; Linssen, L.; Ljuslin, C.; Lofstedt, B.; Loos, R.; Lopez Perez, J. A.; Lourenco, C.; Lyonnet, A.; Machard, A.; Mackenzie, R.; Magini, N.; Maire, G.; Malgeri, L.; Malina, R.; Mannelli, M.; Marchioro, A.; Martin, J.; Meijers, F.; Meridiani, P.; Meschi, E.; Meyer, T.; Meynet Cordonnier, A.; Michaud, J. F.; Mirabito, L.; Moser, R.; Mossiere, F.; Muffat-Joly, J.; Mulders, M.; Mulon, J.; Murer, E.; Mättig, P.; Oh, A.; Onnela, A.; Oriunno, M.; Orsini, L.; Osborne, J. A.; Paillard, C.; Pal, I.; Papotti, G.; Passardi, G.; Patino-Revuelta, A.; Patras, V.; Perea Solano, B.; Perez, E.; Perinic, G.; Pernot, J. F.; Petagna, P.; Petiot, P.; Petit, P.; Petrilli, A.; Pfeiffer, A.; Piccut, C.; Pimiä, M.; Pintus, R.; Pioppi, M.; Placci, A.; Pollet, L.; Postema, H.; Price, M. J.; Principe, R.; Racz, A.; Radermacher, E.; Ranieri, R.; Raymond, G.; Rebecchi, P.; Rehn, J.; Reynaud, S.; Rezvani Naraghi, H.; Ricci, D.; Ridel, M.; Risoldi, M.; Rodrigues Simoes Moreira, P.; Rohlev, A.; Roiron, G.; Rolandi, G.; Rumerio, P.; Runolfsson, O.; Ryjov, V.; Sakulin, H.; Samyn, D.; Santos Amaral, L. C.; Sauce, H.; Sbrissa, E.; Scharff-Hansen, P.; Schieferdecker, P.; Schlatter, W. D.; Schmitt, B.; Schmuecker, H. G.; Schröder, M.; Schwick, C.; Schäfer, C.; Segoni, I.; Sempere Roldán, P.; Sgobba, S.; Sharma, A.; Siegrist, P.; Sigaud, C.; Sinanis, N.; Sobrier, T.; Sphicas, P.; Spiropulu, M.; Stefanini, G.; Strandlie, A.; Szoncsó, F.; Taylor, B. G.; Teller, O.; Thea, A.; Tournefier, E.; Treille, D.; Tropea, P.; Troska, J.; Tsesmelis, E.; Tsirou, A.; Valls, J.; Van Vulpen, I.; Vander Donckt, M.; Vasey, F.; Vazquez Acosta, M.; Veillet, L.; Vichoudis, P.; Waurick, G.; Wellisch, J. P.; Wertelaers, P.; Wilhelmsson, M.; Willers, I. M.; Winkler, M.; Zanetti, M.; Bertl, W.; Deiters, K.; Dick, P.; Erdmann, W.; Feichtinger, D.; Gabathuler, K.; Hochman, Z.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; König, S.; Poerschke, P.; Renker, D.; Rohe, T.; Sakhelashvili, T.; Starodumov, A.; Aleksandrov, V.; Behner, F.; Beniozef, I.; Betev, B.; Blau, B.; Brett, A. M.; Caminada, L.; Chen, Z.; Chivarov, N.; Da Silva Di Calafiori, D.; Dambach, S.; Davatz, G.; Delachenal, V.; Della Marina, R.; Dimov, H.; Dissertori, G.; Dittmar, M.; Djambazov, L.; Dröge, M.; Eggel, C.; Ehlers, J.; Eichler, R.; Elmiger, M.; Faber, G.; Freudenreich, K.; Fuchs, J. F.; Georgiev, G. M.; Grab, C.; Haller, C.; Herrmann, J.; Hilgers, M.; Hintz, W.; Hofer, Hans; Hofer, Heinz; Horisberger, U.; Horvath, I.; Hristov, A.; Humbertclaude, C.; Iliev, B.; Kastli, W.; Kruse, A.; Kuipers, J.; Langenegger, U.; Lecomte, P.; Lejeune, E.; Leshev, G.; Lesmond, C.; List, B.; Luckey, P. D.; Lustermann, W.; Maillefaud, J. D.; Marchica, C.; Maurisset, A.; Meier, B.; Milenovic, P.; Milesi, M.; Moortgat, F.; Nanov, I.; Nardulli, A.; Nessi-Tedaldi, F.; Panev, B.; Pape, L.; Pauss, F.; Petrov, E.; Petrov, G.; Peynekov, M. M.; Pitzl, D.; Punz, T.; Riboni, P.; Riedlberger, J.; Rizzi, A.; Ronga, F. J.; Roykov, P. A.; Röser, U.; Schinzel, D.; Schöning, A.; Sourkov, A.; Stanishev, K.; Stoenchev, S.; Stöckli, F.; Suter, H.; Trüb, P.; Udriot, S.; Uzunova, D. G.; Veltchev, I.; Viertel, G.; von Gunten, H. P.; Waldmeier-Wicki, S.; Weber, R.; Weber, M.; Weng, J.; Wensveen, M.; Wittgenstein, F.; Zagoursky, K.; Alagoz, E.; Amsler, C.; Chiochia, V.; Hoermann, C.; Regenfus, C.; Robmann, P.; Rommerskirchen, T.; Schmidt, A.; Steiner, S.; Tsirigkas, D.; Wilke, L.; Blyth, S.; Chang, Y. H.; Chen, E. A.; Go, A.; Hung, C. C.; Kuo, C. M.; Li, S. W.; Lin, W.; Chang, P.; Chao, Y.; Chen, K. F.; Gao, Z.; Hou, G. W. S.; Hsiung, Y. B.; Lei, Y. J.; Lin, S. W.; Lu, R. S.; Shiu, J. G.; Tzeng, Y. M.; Ueno, K.; Velikzhanin, Y.; Wang, C. C.; Wang, M.-Z.; Aydin, S.; Azman, A.; Bakirci, M. N.; Basegmez, S.; Cerci, S.; Dumanoglu, I.; Erturk, S.; Eskut, E.; Kayis Topaksu, A.; Kisoglu, H.; Kurt, P.; Ozdemir, K.; Ozdes Koca, N.; Ozkurt, H.; Ozturk, S.; Polatöz, A.; Sogut, K.; Topakli, H.; Vergili, M.; Önengüt, G.; Gamsizkan, H.; Sekmen, S.; Serin-Zeyrek, M.; Sever, R.; Zeyrek, M.; Deliomeroglu, M.; Gülmez, E.; Isiksal, E.; Kaya, M.; Kaya, O.; Ozkorucuklu, S.; Sonmez, N.; Grinev, B.; Lyubynskiy, V.; Senchyshyn, V.; Levchuk, L.; Lukyanenko, S.; Soroka, D.; Sorokin, P.; Zub, S.; Anjum, A.; Baker, N.; Hauer, T.; McClatchey, R.; Odeh, M.; Rogulin, D.; Solomonides, A.; Brooke, J. J.; Croft, R.; Cussans, D.; Evans, D.; Frazier, R.; Grant, N.; Hansen, M.; Head, R. D.; Heath, G. P.; Heath, H. F.; Hill, C.; Huckvale, B.; Jackson, J.; Lynch, C.; Mackay, C. K.; Metson, S.; Nash, S. J.; Newbold, D. M.; Presland, A. D.; Probert, M. G.; Reid, E. C.; Smith, V. J.; Tapper, R. J.; Walton, R.; Bateman, E.; Bell, K. W.; Brown, R. M.; Camanzi, B.; Church, I. T.; Cockerill, D. J. A.; Cole, J. E.; Connolly, J. F.; Coughlan, J. A.; Flower, P. S.; Ford, P.; Francis, V. B.; French, M. J.; Galagedera, S. B.; Gannon, W.; Gay, A. P. R.; Geddes, N. I.; Greenhalgh, R. J. S.; Halsall, R. N. J.; Haynes, W. J.; Hill, J. A.; Jacob, F. R.; Jeffreys, P. W.; Jones, L. L.; Kennedy, B. W.; Lintern, A. L.; Lodge, A. B.; Maddox, A. J.; Morrissey, Q. R.; Murray, P.; Patrick, G. N.; Pattison, C. A. X.; Pearson, M. R.; Quinton, S. P. H.; Rogers, G. J.; Salisbury, J. G.; Shah, A. A.; Shepherd-Themistocleous, C. H.; Smith, B. J.; Sproston, M.; Stephenson, R.; Taghavi, S.; Tomalin, I. R.; Torbet, M. J.; Williams, J. H.; Womersley, W. J.; Worm, S. D.; Xing, F.; Apollonio, M.; Arteche, F.; Bainbridge, R.; Barber, G.; Barrillon, P.; Batten, J.; Beuselinck, R.; Brambilla Hall, P. M.; Britton, D.; Cameron, W.; Clark, D. E.; Clark, I. W.; Colling, D.; Cripps, N.; Davies, G.; Della Negra, M.; Dewhirst, G.; Dris, S.; Foudas, C.; Fulcher, J.; Futyan, D.; Graham, D. J.; Greder, S.; Greenwood, S.; Hall, G.; Hassard, J. F.; Hays, J.; Iles, G.; Kasey, V.; Khaleeq, M.; Leaver, J.; Lewis, P.; MacEvoy, B. C.; Maroney, O.; McLeod, E. M.; Miller, D. G.; Nash, J.; Nikitenko, A.; Noah Messomo, E.; Noy, M.; Papageorgiou, A.; Pesaresi, M.; Petridis, K.; Price, D. R.; Qu, X.; Raymond, D. M.; Rose, A.; Rutherford, S.; Ryan, M. J.; Sciacca, F.; Seez, C.; Sharp, P.; Sidiropoulos, G.; Stettler, M.; Stoye, M.; Striebig, J.; Takahashi, M.; Tallini, H.; Tapper, A.; Timlin, C.; Toudup, L.; Virdee, T.; Wakefield, S.; Walsham, P.; Wardrope, D.; Wingham, M.; Zhang, Y.; Zorba, O.; Da Via, C.; Goitom, I.; Hobson, P. R.; Imrie, D. C.; Reid, I.; Selby, C.; Sharif, O.; Teodorescu, L.; Watts, S. J.; Yaselli, I.; Hazen, E.; Heering, A.; Heister, A.; Lawlor, C.; Lazic, D.; Machado, E.; Rohlf, J.; Sulak, L.; Varela Rodriguez, F.; Wu, S. X.; Avetisyan, A.; Bose, T.; Christofek, L.; Cutts, D.; Esen, S.; Hooper, R.; Landsberg, G.; Narain, M.; Nguyen, D.; Speer, T.; Tsang, K. V.; Breedon, R.; Case, M.; Chertok, M.; Conway, J.; Cox, P. T.; Dolen, J.; Erbacher, R.; Fisyak, Y.; Friis, E.; Grim, G.; Holbrook, B.; Ko, W.; Kopecky, A.; Lander, R.; Lin, F. C.; Lister, A.; Maruyama, S.; Pellett, D.; Rowe, J.; Searle, M.; Smith, J.; Soha, A.; Squires, M.; Tripathi, M.; Vasquez Sierra, R.; Veelken, C.; Andreev, V.; Arisaka, K.; Bonushkin, Y.; Chandramouly, S.; Cline, D.; Cousins, R.; Erhan, S.; Hauser, J.; Ignatenko, M.; Jarvis, C.; Lisowski, B.; Matthey, C.; Mohr, B.; Mumford, J.; Otwinowski, S.; Pischalnikov, Y.; Rakness, G.; Schlein, P.; Shi, Y.; Tannenbaum, B.; Tucker, J.; Valuev, V.; Wallny, R.; Wang, H. G.; Yang, X.; Zheng, Y.; Andreeva, J.; Babb, J.; Campana, S.; Chrisman, D.; Clare, R.; Ellison, J.; Fortin, D.; Gary, J. W.; Gorn, W.; Hanson, G.; Jeng, G. Y.; Kao, S. C.; Layter, J. G.; Liu, F.; Liu, H.; Luthra, A.; Pasztor, G.; Rick, H.; Satpathy, A.; Shen, B. C.; Stringer, R.; Sytnik, V.; Tran, P.; Villa, S.; Wilken, R.; Wimpenny, S.; Zer-Zion, D.; Branson, J. G.; Coarasa Perez, J. A.; Dusinberre, E.; Kelley, R.; Lebourgeois, M.; Letts, J.; Lipeles, E.; Mangano, B.; Martin, T.; Mojaver, M.; Muelmenstaedt, J.; Norman, M.; Paar, H. P.; Petrucci, A.; Pi, H.; Pieri, M.; Rana, A.; Sani, M.; Sharma, V.; Simon, S.; White, A.; Würthwein, F.; Yagil, A.; Affolder, A.; Allen, A.; Campagnari, C.; D'Alfonso, M.; Dierlamm, A.; Garberson, J.; Hale, D.; Incandela, J.; Kalavase, P.; Koay, S. A.; Kovalskyi, D.; Krutelyov, V.; Kyre, S.; Lamb, J.; Lowette, S.; Nikolic, M.; Pavlunin, V.; Rebassoo, F.; Ribnik, J.; Richman, J.; Rossin, R.; Shah, Y. S.; Stuart, D.; Swain, S.; Vlimant, J. R.; White, D.; Witherell, M.; Bornheim, A.; Bunn, J.; Chen, J.; Denis, G.; Galvez, P.; Gataullin, M.; Legrand, I.; Litvine, V.; Ma, Y.; Mao, R.; Nae, D.; Narsky, I.; Newman, H. B.; Orimoto, T.; Rogan, C.; Shevchenko, S.; Steenberg, C.; Su, X.; Thomas, M.; Timciuc, V.; van Lingen, F.; Veverka, J.; Voicu, B. R.; Weinstein, A.; Wilkinson, R.; Xia, Y.; Yang, Y.; Zhang, L. Y.; Zhu, K.; Zhu, R. Y.; Ferguson, T.; Jang, D. W.; Jun, S. Y.; Paulini, M.; Russ, J.; Terentyev, N.; Vogel, H.; Vorobiev, I.; Bunce, M.; Cumalat, J. P.; Dinardo, M. E.; Drell, B. R.; Ford, W. T.; Givens, K.; Heyburn, B.; Johnson, D.; Nauenberg, U.; Stenson, K.; Wagner, S. R.; Agostino, L.; Alexander, J.; Blekman, F.; Cassel, D.; Das, S.; Duboscq, J. E.; Gibbons, L. K.; Heltsley, B.; Jones, C. D.; Kuznetsov, V.; Patterson, J. R.; Riley, D.; Ryd, A.; Stroiney, S.; Sun, W.; Thom, J.; Vaughan, J.; Wittich, P.; Beetz, C. P.; Cirino, G.; Podrasky, V.; Sanzeni, C.; Winn, D.; Abdullin, S.; Afaq, M. A.; Albrow, M.; Amundson, J.; Apollinari, G.; Atac, M.; Badgett, W.; Bakken, J. A.; Baldin, B.; Banicz, K.; Bauerdick, L. A. T.; Baumbaugh, A.; Berryhill, J.; Bhat, P. C.; Binkley, M.; Bloch, I.; Borcherding, F.; Boubekeur, A.; Bowden, M.; Burkett, K.; Butler, J. N.; Cheung, H. W. K.; Chevenier, G.; Chlebana, F.; Churin, I.; Cihangir, S.; Dagenhart, W.; Demarteau, M.; Dykstra, D.; Eartly, D. P.; Elias, J. E.; Elvira, V. D.; Evans, D.; Fisk, I.; Freeman, J.; Gaines, I.; Gartung, P.; Geurts, F. J. M.; Giacchetti, L.; Glenzinski, D. A.; Gottschalk, E.; Grassi, T.; Green, D.; Grimm, C.; Guo, Y.; Gutsche, O.; Hahn, A.; Hanlon, J.; Harris, R. M.; Hesselroth, T.; Holm, S.; Holzman, B.; James, E.; Jensen, H.; Johnson, M.; Joshi, U.; Klima, B.; Kossiakov, S.; Kousouris, K.; Kowalkowski, J.; Kramer, T.; Kwan, S.; Lei, C. M.; Leininger, M.; Los, S.; Lueking, L.; Lukhanin, G.; Lusin, S.; Maeshima, K.; Marraffino, J. M.; Mason, D.; McBride, P.; Miao, T.; Moccia, S.; Mokhov, N.; Mrenna, S.; Murray, S. J.; Newman-Holmes, C.; Noeding, C.; O'Dell, V.; Paterno, M.; Petravick, D.; Pordes, R.; Prokofyev, O.; Ratnikova, N.; Ronzhin, A.; Sekhri, V.; Sexton-Kennedy, E.; Sfiligoi, I.; Shaw, T. M.; Skup, E.; Smith, R. P.; Spalding, W. J.; Spiegel, L.; Stavrianakou, M.; Stiehr, G.; Stone, A. L.; Suzuki, I.; Tan, P.; Tanenbaum, W.; Temple, L. E.; Tkaczyk, S.; Uplegger, L.; Vaandering, E. W.; Vidal, R.; Wands, R.; Wenzel, H.; Whitmore, J.; Wicklund, E.; Wu, W. M.; Wu, Y.; Yarba, J.; Yarba, V.; Yumiceva, F.; Yun, J. C.; Zimmerman, T.; Acosta, D.; Avery, P.; Barashko, V.; Bartalini, P.; Bourilkov, D.; Cavanaugh, R.; Dolinsky, S.; Drozdetskiy, A.; Field, R. D.; Fu, Y.; Furic, I. K.; Gorn, L.; Holmes, D.; Kim, B. J.; Klimenko, S.; Konigsberg, J.; Korytov, A.; Kotov, K.; Levchenko, P.; Madorsky, A.; Matchev, K.; Mitselmakher, G.; Pakhotin, Y.; Prescott, C.; Ramond, L.; Ramond, P.; Schmitt, M.; Scurlock, B.; Stasko, J.; Stoeck, H.; Wang, D.; Yelton, J.; Gaultney, V.; Kramer, L.; Lebolo, L. M.; Linn, S.; Markowitz, P.; Martinez, G.; Rodriguez, J. L.; Adams, T.; Askew, A.; Atramentov, O.; Bertoldi, M.; Dharmaratna, W. G. D.; Gershtein, Y.; Gleyzer, S. V.; Hagopian, S.; Hagopian, V.; Jenkins, C. J.; Johnson, K. F.; Prosper, H.; Simek, D.; Thomaston, J.; Baarmand, M.; Baksay, L.; Guragain, S.; Hohlmann, M.; Mermerkaya, H.; Ralich, R.; Vodopiyanov, I.; Adams, M. R.; Anghel, I. M.; Apanasevich, L.; Barannikova, O.; Bazterra, V. E.; Betts, R. R.; Dragoiu, C.; Garcia-Solis, E. J.; Gerber, C. E.; Hofman, D. J.; Hollis, R.; Iordanova, A.; Khalatian, S.; Mironov, C.; Shabalina, E.; Smoron, A.; Varelas, N.; Akgun, U.; Albayrak, E. A.; Ayan, A. S.; Briggs, R.; Cankocak, K.; Clarida, W.; Cooper, A.; Debbins, P.; Duru, F.; Fountain, M.; McCliment, E.; Merlo, J. P.; Mestvirishvili, A.; Miller, M. J.; Moeller, A.; Newsom, C. R.; Norbeck, E.; Olson, J.; Onel, Y.; Perera, L.; Schmidt, I.; Wang, S.; Yetkin, T.; Anderson, E. W.; Chakir, H.; Hauptman, J. M.; Lamsa, J.; Barnett, B. A.; Blumenfeld, B.; Chien, C. Y.; Giurgiu, G.; Gritsan, A.; Kim, D. W.; Lae, C. K.; Maksimovic, P.; Swartz, M.; Tran, N.; Baringer, P.; Bean, A.; Chen, J.; Coppage, D.; Grachov, O.; Murray, M.; Radicci, V.; Wood, J. S.; Zhukova, V.; Bandurin, D.; Bolton, T.; Kaadze, K.; Kahl, W. E.; Maravin, Y.; Onoprienko, D.; Sidwell, R.; Wan, Z.; Dahmes, B.; Gronberg, J.; Hollar, J.; Lange, D.; Wright, D.; Wuest, C. R.; Baden, D.; Bard, R.; Eno, S. C.; Ferencek, D.; Hadley, N. J.; Kellogg, R. G.; Kirn, M.; Kunori, S.; Lockner, E.; Ratnikov, F.; Santanastasio, F.; Skuja, A.; Toole, T.; Wang, L.; Wetstein, M.; Alver, B.; Ballintijn, M.; Bauer, G.; Busza, W.; Gomez Ceballos, G.; Hahn, K. A.; Harris, P.; Klute, M.; Kravchenko, I.; Li, W.; Loizides, C.; Ma, T.; Nahn, S.; Paus, C.; Pavlon, S.; Piedra Gomez, J.; Roland, C.; Roland, G.; Rudolph, M.; Stephans, G.; Sumorok, K.; Vaurynovich, S.; Wenger, E. A.; Wyslouch, B.; Bailleux, D.; Cooper, S.; Cushman, P.; DeBenedetti, A.; Dolgopolov, A.; Dudero, P. R.; Egeland, R.; Franzoni, G.; Gilbert, W. J.; Gong, D.; Grahl, J.; Haupt, J.; Klapoetke, K.; Kronkvist, I.; Kubota, Y.; Mans, J.; Rusack, R.; Sengupta, S.; Sherwood, B.; Singovsky, A.; Vikas, P.; Zhang, J.; Booke, M.; Cremaldi, L. M.; Godang, R.; Kroeger, R.; Reep, M.; Reidy, J.; Sanders, D. A.; Sonnek, P.; Summers, D.; Watkins, S.; Bloom, K.; Bockelman, B.; Claes, D. R.; Dominguez, A.; Eads, M.; Furukawa, M.; Keller, J.; Kelly, T.; Lundstedt, C.; Malik, S.; Snow, G. R.; Swanson, D.; Ecklund, K. M.; Iashvili, I.; Kharchilava, A.; Kumar, A.; Strang, M.; Alverson, G.; Barberis, E.; Boeriu, O.; Eulisse, G.; McCauley, T.; Musienko, Y.; Muzaffar, S.; Osborne, I.; Reucroft, S.; Swain, J.; Taylor, L.; Tuura, L.; Gobbi, B.; Kubantsev, M.; Kubik, A.; Ofierzynski, R. A.; Schmitt, M.; Spencer, E.; Stoynev, S.; Szleper, M.; Velasco, M.; Won, S.; Andert, K.; Baumbaugh, B.; Beiersdorf, B. A.; Castle, L.; Chorny, J.; Goussiou, A.; Hildreth, M.; Jessop, C.; Karmgard, D. J.; Kolberg, T.; Marchant, J.; Marinelli, N.; McKenna, M.; Ruchti, R.; Vigneault, M.; Wayne, M.; Wiand, D.; Bylsma, B.; Durkin, L. S.; Gilmore, J.; Gu, J.; Killewald, P.; Ling, T. Y.; Rush, C. J.; Sehgal, V.; Williams, G.; Adam, N.; Chidzik, S.; Denes, P.; Elmer, P.; Garmash, A.; Gerbaudo, D.; Halyo, V.; Jones, J.; Marlow, D.; Olsen, J.; Piroué, P.; Stickland, D.; Tully, C.; Werner, J. S.; Wildish, T.; Wynhoff, S.; Xie, Z.; Huang, X. T.; Lopez, A.; Mendez, H.; Ramirez Vargas, J. E.; Zatserklyaniy, A.; Apresyan, A.; Arndt, K.; Barnes, V. E.; Bolla, G.; Bortoletto, D.; Bujak, A.; Everett, A.; Fahling, M.; Garfinkel, A. F.; Gutay, L.; Ippolito, N.; Kozhevnikov, Y.; Laasanen, A. T.; Liu, C.; Maroussov, V.; Medved, S.; Merkel, P.; Miller, D. H.; Miyamoto, J.; Neumeister, N.; Pompos, A.; Roy, A.; Sedov, A.; Shipsey, I.; Cuplov, V.; Parashar, N.; Bargassa, P.; Lee, S. J.; Liu, J. H.; Maronde, D.; Matveev, M.; Nussbaum, T.; Padley, B. P.; Roberts, J.; Tumanov, A.; Bodek, A.; Budd, H.; Cammin, J.; Chung, Y. S.; DeBarbaro, P.; Demina, R.; Ginther, G.; Gotra, Y.; Korjenevski, S.; Miner, D. C.; Sakumoto, W.; Slattery, P.; Zielinski, M.; Bhatti, A.; Demortier, L.; Goulianos, K.; Hatakeyama, K.; Mesropian, C.; Bartz, E.; Chuang, S. H.; Doroshenko, J.; Halkiadakis, E.; Jacques, P. F.; Khits, D.; Lath, A.; Macpherson, A.; Plano, R.; Rose, K.; Schnetzer, S.; Somalwar, S.; Stone, R.; Watts, T. L.; Cerizza, G.; Hollingsworth, M.; Lazoflores, J.; Ragghianti, G.; Spanier, S.; York, A.; Aurisano, A.; Golyash, A.; Kamon, T.; Nguyen, C. N.; Pivarski, J.; Safonov, A.; Toback, D.; Weinberger, M.; Akchurin, N.; Berntzon, L.; Carrell, K. W.; Gumus, K.; Jeong, C.; Kim, H.; Lee, S. W.; McGonagill, B. G.; Roh, Y.; Sill, A.; Spezziga, M.; Thomas, R.; Volobouev, I.; Washington, E.; Wigmans, R.; Yazgan, E.; Bapty, T.; Engh, D.; Florez, C.; Johns, W.; Keskinpala, T.; Luiggi Lopez, E.; Neema, S.; Nordstrom, S.; Pathak, S.; Sheldon, P.; Andelin, D.; Arenton, M. W.; Balazs, M.; Buehler, M.; Conetti, S.; Cox, B.; Hirosky, R.; Humphrey, M.; Imlay, R.; Ledovskoy, A.; Phillips, D., II; Powell, H.; Ronquest, M.; Yohay, R.; Anderson, M.; Baek, Y. W.; Bellinger, J. N.; Bradley, D.; Cannarsa, P.; Carlsmith, D.; Crotty, I.; Dasu, S.; Feyzi, F.; Gorski, T.; Gray, L.; Grogg, K. S.; Grothe, M.; Jaworski, M.; Klabbers, P.; Klukas, J.; Lanaro, A.; Lazaridis, C.; Leonard, J.; Loveless, R.; Magrans de Abril, M.; Mohapatra, A.; Ott, G.; Smith, W. H.; Weinberg, M.; Wenman, D.; Atoian, G. S.; Dhawan, S.; Issakov, V.; Neal, H.; Poblaguev, A.; Zeller, M. E.; Abdullaeva, G.; Avezov, A.; Fazylov, M. I.; Gasanov, E. M.; Khugaev, A.; Koblik, Y. N.; Nishonov, M.; Olimov, K.; Umaraliev, A.; Yuldashev, B. S.
2008-08-01
The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 1034 cm-2 s-1 (1027 cm-2 s-1). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4π solid angle. Forward sampling calorimeters extend the pseudorapidity coverage to high values (|η| <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.
A review of advances in pixel detectors for experiments with high rate and radiation
NASA Astrophysics Data System (ADS)
Garcia-Sciveres, Maurice; Wermes, Norbert
2018-06-01
The large Hadron collider (LHC) experiments ATLAS and CMS have established hybrid pixel detectors as the instrument of choice for particle tracking and vertexing in high rate and radiation environments, as they operate close to the LHC interaction points. With the high luminosity-LHC upgrade now in sight, for which the tracking detectors will be completely replaced, new generations of pixel detectors are being devised. They have to address enormous challenges in terms of data throughput and radiation levels, ionizing and non-ionizing, that harm the sensing and readout parts of pixel detectors alike. Advances in microelectronics and microprocessing technologies now enable large scale detector designs with unprecedented performance in measurement precision (space and time), radiation hard sensors and readout chips, hybridization techniques, lightweight supports, and fully monolithic approaches to meet these challenges. This paper reviews the world-wide effort on these developments.
Laboratory and testbeam results for thin and epitaxial planar sensors for HL-LHC
Bubna, M.; Bolla, G.; Bortoletto, D.; ...
2015-08-03
The High-Luminosity LHC (HL-LHC) upgrade of the CMS pixel detector will require the development of novel pixel sensors which can withstand the increase in instantaneous luminosity to L = 5 × 10 34 cm –2s –1 and collect ~ 3000fb –1 of data. The innermost layer of the pixel detector will be exposed to doses of about 10 16 n eq/ cm 2. Hence, new pixel sensors with improved radiation hardness need to be investigated. A variety of silicon materials (Float-zone, Magnetic Czochralski and Epitaxially grown silicon), with thicknesses from 50 μm to 320 μm in p-type and n-type substrates have beenmore » fabricated using single-sided processing. The effect of reducing the sensor active thickness to improve radiation hardness by using various techniques (deep diffusion, wafer thinning, or growing epitaxial silicon on a handle wafer) has been studied. Furthermore, the results for electrical characterization, charge collection efficiency, and position resolution of various n-on-p pixel sensors with different substrates and different pixel geometries (different bias dot gaps and pixel implant sizes) will be presented.« less
Suh, Sungho; Itoh, Shinya; Aoyama, Satoshi; Kawahito, Shoji
2010-01-01
For low-noise complementary metal-oxide-semiconductor (CMOS) image sensors, the reduction of pixel source follower noises is becoming very important. Column-parallel high-gain readout circuits are useful for low-noise CMOS image sensors. This paper presents column-parallel high-gain signal readout circuits, correlated multiple sampling (CMS) circuits and their noise reduction effects. In the CMS, the gain of the noise cancelling is controlled by the number of samplings. It has a similar effect to that of an amplified CDS for the thermal noise but is a little more effective for 1/f and RTS noises. Two types of the CMS with simple integration and folding integration are proposed. In the folding integration, the output signal swing is suppressed by a negative feedback using a comparator and one-bit D-to-A converter. The CMS circuit using the folding integration technique allows to realize a very low-noise level while maintaining a wide dynamic range. The noise reduction effects of their circuits have been investigated with a noise analysis and an implementation of a 1Mpixel pinned photodiode CMOS image sensor. Using 16 samplings, dynamic range of 59.4 dB and noise level of 1.9 e(-) for the simple integration CMS and 75 dB and 2.2 e(-) for the folding integration CMS, respectively, are obtained.
NASA Astrophysics Data System (ADS)
Guthoff, Moritz; Afanaciev, Konstantin; Dabrowski, Anne; de Boer, Wim; Lange, Wolfgang; Lohmann, Wolfgang; Stickland, David
2013-12-01
The Beam Condition Monitor (BCM) of the CMS detector at the LHC is a protection device similar to the LHC Beam Loss Monitor system. While the electronics used is the same, poly-crystalline Chemical Vapor Deposition (pCVD) diamonds are used instead of ionization chambers as the BCM sensor material. The main purpose of the system is the protection of the silicon Pixel and Strip tracking detectors by inducing a beam dump, if the beam losses are too high in the CMS detector. By comparing the detector current with the instantaneous luminosity, the BCM detector efficiency can be monitored. The number of radiation-induced defects in the diamond, reduces the charge collection distance, and hence lowers the signal. The number of these induced defects can be simulated using the FLUKA Monte Carlo simulation. The cross-section for creating defects increases with decreasing energies of the impinging particles. This explains, why diamond sensors mounted close to heavy calorimeters experience more radiation damage, because of the high number of low energy neutrons in these regions. The signal decrease was stronger than expected from the number of simulated defects. Here polarization from trapped charge carriers in the defects is a likely candidate for explaining the difference, as suggested by Transient Current Technique (TCT) measurements. A single-crystalline (sCVD) diamond sensor shows a faster relative signal decrease than a pCVD sensor mounted at the same location. This is expected, since the relative increase in the number of defects is larger in sCVD than in pCVD sensors.
SiPM based readout system for PbWO4 crystals
NASA Astrophysics Data System (ADS)
Berra, A.; Bolognini, D.; Bonfanti, S.; Bonvicini, V.; Lietti, D.; Penzo, A.; Prest, M.; Stoppani, L.; Vallazza, E.
2013-08-01
Silicon PhotoMultipliers (SiPMs) consist of a matrix of small passively quenched silicon avalanche photodiodes operated in limited Geiger-mode (GM-APDs) and read out in parallel from a common output node. Each pixel (with a typical size in the 20-100 μm range) gives the same current response when hit by a photon; the SiPM output signal is the sum of the signals of all the pixels, which depends on the light intensity. The main advantages of SiPMs with respect to photomultiplier tubes (PMTs) are essentially the small dimensions, the insensitivity to magnetic fields and a low bias voltage. This contribution presents the performance of a SiPM based readout system for crystal calorimeters developed in the framework of the FACTOR/TWICE collaboration. The SiPM used for the test is a new device produced by FBK-irst which consists in a matrix of four sensors embedded in the same silicon substrate, called QUAD. The SiPM has been coupled to a lead tungstate crystal, an early-prototype version of the crystals developed for the electromagnetic calorimeter of the CMS experiment. New tests are foreseen using a complete module consisting of nine crystals, each one readout by two QUADs.
Simulation study of pixel detector charge digitization
NASA Astrophysics Data System (ADS)
Wang, Fuyue; Nachman, Benjamin; Sciveres, Maurice; Lawrence Berkeley National Laboratory Team
2017-01-01
Reconstruction of tracks from nearly overlapping particles, called Tracking in Dense Environments (TIDE), is an increasingly important component of many physics analyses at the Large Hadron Collider as signatures involving highly boosted jets are investigated. TIDE makes use of the charge distribution inside a pixel cluster to resolve tracks that share one of more of their pixel detector hits. In practice, the pixel charge is discretized using the Time-over-Threshold (ToT) technique. More charge information is better for discrimination, but more challenging for designing and operating the detector. A model of the silicon pixels has been developed in order to study the impact of the precision of the digitized charge distribution on distinguishing multi-particle clusters. The output of the GEANT4-based simulation is used to train neutral networks that predict the multiplicity and location of particles depositing energy inside one cluster of pixels. By studying the multi-particle cluster identification efficiency and position resolution, we quantify the trade-off between the number of ToT bits and low-level tracking inputs. As both ATLAS and CMS are designing upgraded detectors, this work provides guidance for the pixel module designs to meet TIDE needs. Work funded by the China Scholarship Council and the Office of High Energy Physics of the U.S. Department of Energy under contract DE-AC02-05CH11231.
Vehicle and cargo container inspection system for drugs
NASA Astrophysics Data System (ADS)
Verbinski, Victor V.; Orphan, Victor J.
1999-06-01
A vehicle and cargo container inspection system has been developed which uses gamma-ray radiography to produce digital images useful for detection of drugs and other contraband. The system is comprised of a 1 Ci Cs137 gamma-ray source collimated into a fan beam which is aligned with a linear array of NaI gamma-ray detectors located on the opposite side of the container. The NaI detectors are operated in the pulse-counting mode. A digital image of the vehicle or container is obtained by moving the aligned source and detector array relative to the object. Systems have been demonstrated in which the object is stationary (source and detector array move on parallel tracks) and in which the object moves past a stationary source and detector array. Scanning speeds of ˜30 cm/s with a pixel size (at the object) of ˜1 cm have been achieved. Faster scanning speeds of ˜2 m/s have been demonstrated on railcars with more modest spatial resolution (4 cm pixels). Digital radiographic images are generated from the detector count rates. These images, recorded on a PC-based data acquisition and display system, are shown from several applications: 1) inspection of trucks and containers at a border crossing, 2) inspection of railcars at a border crossing, 3) inspection of outbound cargo containers for stolen automobiles, and 4) inspection of trucks and cars for terrorist bombs.
Characterization of thin irradiated epitaxial silicon sensors for the CMS phase II pixel upgrade
NASA Astrophysics Data System (ADS)
Centis Vignali, M.
2015-02-01
The high-luminosity upgrade of the Large Hadron Collider foreseen for 2023 resulted on the decision to replace the tracker system of the CMS experiment. The innermost layer of the new pixel detector will experience fluences in the order of phieq ≈ 1016 cm-2 and a dose of ≈ 5 MGy after an integrated luminosity of 3000 fb-1. Several materials and designs are under investigation in order to build a detector that can withstand such high fluences. Thin planar silicon sensors are good candidates to achieve this goal since the degradation of the signal produced by traversing particles is less severe than for thicker devices. A study has been carried out in order to characterize highly irradiated planar epitaxial silicon sensors with an active thickness of 100 μm. The investigation includes pad diodes and strip detectors irradiated up to a fluence of phieq = 1.3 × 1016 cm-2, and 3 × 1015 cm-2, respectively. The electrical properties of diodes have been characterized using laboratory measurements, while measurements have been carried out at the DESY II test beam facility to characterize the charge collection of the strip detectors. A beam telescope has been used to determine precisely the impact position of beam particles on the sensor. This allows the unbiased extraction of the charge deposited in the strip sensor and good identification of the noise. In this paper, the results obtained for p-bulk sensors are shown. The charge collection efficiency of the strip sensors is 90% at 1000 V after a fluence of phieq = 3 × 1015 cm-2. The irradiated diodes show charge multiplication effects. The impact of the threshold applied to a detector on its efficiency is also discussed.
Han, Sang-Pil; Ko, Hyunsung; Kim, Namje; Lee, Won-Hui; Moon, Kiwon; Lee, Il-Min; Lee, Eui Su; Lee, Dong Hun; Lee, Wangjoo; Han, Seong-Tae; Choi, Sung-Wook; Park, Kyung Hyun
2014-11-17
We demonstrate real-time continuous-wave terahertz (THz) line-scanned imaging based on a 1 × 240 InGaAs Schottky barrier diode (SBD) array detector with a scan velocity of 25 cm/s, a scan line length of 12 cm, and a pixel size of 0.5 × 0.5 mm². Foreign substances, such as a paper clip with a spatial resolution of approximately 1 mm that is hidden under a cracker, are clearly detected by this THz line-scanning system. The system consists of the SBD array detector, a 200-GHz gyrotron source, a conveyor system, and several optical components such as a high-density polyethylene cylindrical lens, metal cylindrical mirror, and THz wire-grid polarizer. Using the THz polarizer, the signal-to-noise ratio of the SBD array detector improves because the quality of the source beam is enhanced.
NASA Astrophysics Data System (ADS)
Affolder, Anthony; Allport, Phil; Casse, Gianluigi
2010-11-01
The planned luminosity upgrade of the Large Hadron Collider at CERN (Super-LHC) will provide a challenging environment for the tracking and vertexing detector systems. Planar, segmented silicon detectors are one of the few radiation tolerant technologies under consideration for use for the Super-LHC tracking detectors in either pixel or strip geometries. In this paper, charge collection measurements are made with planar silicon sensors with 2 different substrate materials (float zone and magnetic Czochralski) and 3 different diode configurations (p+ strip in n-bulk, n+ strip in n-bulk, and n+ strip in p-bulk). For the first time, a comparison of the charge collection of these devices will be made after irradiation up to 6 ×1014 neq cm-2 with 280 MeV charged pions, and up to 2.2 ×1016 neq cm-2 with 26 MeV protons. This study covers the expected range of final fluences for the different layers of pixel and microstrip sensors of the ATLAS and CMS experiments at the Super-LHC. These measurements have been carried out using analogue, high-speed (40 MHz) electronics and a Strontium-90 beta source.
High Energy Physics Research with the CMS Experiment at CERN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, Gail G.
2013-05-31
The highlight of our last budget period, June 1, 2010, to May 31, 2013, was the discovery of the Higgs boson by the ATLAS and CMS experiments at the CERN Large Hadron Collider (LHC), announced on July 4, 2012, and for which François Englert and Peter Higgs were awarded the 2013 Nobel Prize in Physics on October 8, 2013. The Higgs boson was postulated in 1964 to explain how elementary particles obtain mass and was the missing piece of the Standard Model. However, the Standard Model does not describe everything that we know. There are many unanswered questions, such asmore » how can the Higgs boson have the mass that we have observed, are there more Higgs bosons, why is there more matter than antimatter, and what is the invisible dark matter, which constitutes about 85% of the matter in the universe. Our group played a significant role in the discovery of the Higgs boson and in subsequent analyses. We also carried out searches for new physics, in ways that could help elucidate some of the remaining questions. Our role in the CMS detector focused on the Tracker, a silicon strip outer tracker and pixel inner tracker.« less
Particle Tracking Model (PTM) with Coastal Modeling System (CMS)
2015-11-04
Coastal Inlets Research Program Particle Tracking Model (PTM) with Coastal Modeling System ( CMS ) The Particle Tracking Model (PTM) is a Lagrangian...currents and waves. The Coastal Inlets Research Program (CIRP) supports the PTM with the Coastal Modeling System ( CMS ), which provides coupled wave...and current forcing for PTM simulations. CMS -PTM is implemented in the Surface-water Modeling System, a GUI environment for input development
A new timing detector for the CT-PPS project
NASA Astrophysics Data System (ADS)
Arcidiacono, R.; Cms; TOTEM Collaborations
2017-02-01
The CT-PPS detector will be installed close to the beam line on both sides of CMS, 200 m downstream the interaction point. This detector will measure forward scattered protons, allowing detailed studies of diffractive hadron physics and Central Exclusive Production. The main components of the CT-PPS detector are a silicon tracking system and a timing system. In this contribution we present the proposal of an innovative solution for the timing system, based on Ultra-Fast Silicon Detectors (UFSD). UFSD are a novel concept of silicon detectors potentially able to obtain the necessary time resolution (∼20 ps on the proton arrival time). The use of UFSD has also other attractive features as its material budget is small and the pixel geometries can be tailored to the precise physics distribution of protons. UFSD prototypes for CT-PPS have been designed by CNM (Barcelona) and FBK (Trento): we will present the status of the sensor productions and of the low-noise front-end electronics currently under development and test.
The Status of the Cms Experiment
NASA Astrophysics Data System (ADS)
Green, Dan
The CMS experiment was completely assembled in the fall of 2008 after a decade of design, construction and installation. During the last two years, cosmic ray data were taken on a regular basis. These data have enabled CMS to align the detector components, both spatially and temporally. Initial use of muons has also established the relative alignment of the CMS tracking and muon systems. In addition, the CMS calorimetry has been crosschecked with test beam data, thus providing an initial energy calibration of CMS calorimetry to about 5%. The CMS magnet has been powered and field mapped. The trigger and data acquisition systems have been installed and run at full speed. The tiered data analysis system has been exercised at full design bandwidth for Tier0, Tier1 and Tier2 sites. Monte Carlo simulation of the CMS detector has been constructed at a detailed geometric level and has been tuned to test beam and other production data to provide a realistic model of the CMS detector prior to first collisions.
NASA Technical Reports Server (NTRS)
Liebowitz, J.
1985-01-01
The development of an expert system prototype for determining software functional requirements for NASA Goddard's Command Management System (CMS) is described. The role of the CMS is to transform general requests into specific spacecraft commands with command execution conditions. The CMS is part of the NASA Data System which entails the downlink of science and engineering data from NASA near-earth satellites to the user, and the uplink of command and control data to the spacecraft. Subjects covered include: the problem environment of determining CMS software functional requirements; the expert system approach for handling CMS requirements development; validation and evaluation procedures for the expert system.
23 CFR 970.214 - Federal lands congestion management system (CMS).
Code of Federal Regulations, 2014 CFR
2014-04-01
... 23 Highways 1 2014-04-01 2014-04-01 false Federal lands congestion management system (CMS). 970... LANDS HIGHWAYS NATIONAL PARK SERVICE MANAGEMENT SYSTEMS National Park Service Management Systems § 970.214 Federal lands congestion management system (CMS). (a) For purposes of this section, congestion...
1986-04-29
COMPILER VALIDATION SUMMARY REPORT: International Business Machines Corporation IBM Development System for the Ada Language for VM/CMS, Version 1.0 IBM 4381...tested using command scripts provided by International Business Machines Corporation. These scripts were reviewed by the validation team. Test.s were run...s): IBM 4381 (System/370) Operating System: VM/CMS, release 3.6 International Business Machines Corporation has made no deliberate extensions to the
Exemption of certain systems of records under the Privacy Act. Proposed rule.
2007-05-25
This proposed rule would exempt the four system of records from subsections (c)(3), (d)(1) through (d)(4),(e)(4)(G) and (H), and (f) of the Privacy Act pursuant to 5 U.S.C. 552a (k)(2): The Automated Survey Processing Environment (ASPEN) Complaint/Incidents Tracking System ("ACTS"), HHS/CMS, System No. 09-70-0565; the Health Insurance Portability and Accountability Act (HIPAA) Information Tracking System ("HITS"), HHS/CMS, System No. 09-70-0544; the Organ Procurement Organizations System ("OPOS"), HHS/CMS, System No. 09-70-0575; and the Fraud Investigation Database ("FID"), HHS/CMS, System No. 09-70-0527.
Exemption of certain systems of records under the Privacy Act. Final rule.
2008-09-26
This final rule exempts four systems of records (SORs) from subsections (c)(3), (d)(1) through (d)(4), (e)(4)(G) and (H), and (f) of the Privacy Act pursuant to 5 U.S.C. 552a(k)(2): The Automated Survey Processing Environment (ASPEN) Complaint/ Incidents Tracking System (ACTS), HHS/CMS, System No. 09-70-0565; the Health Insurance Portability and Accountability Act (HIPAA) Information Tracking System (HITS), HHS/CMS, System No. 09-70-0544; the Organ Procurement Organizations System (OPOS), HHS/CMS, System No. 09-70- 0575; and the Fraud Investigation Database (FID), HHS/CMS, System No. 09-70-0527.
Diamond Pixel Luminosity Telescopes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halyo, Valerie
2014-12-15
In this document, Halyo summaries her key contributions to CMS at the LHC and provide an explanation of their importance and her role in each project. At the end Halyo describes her recent research interest that includes GPU/MIC Acceleration of the High Level Trigger (HLT) to Extend the Physics Research at the LHC. A description of her work the recent promising results that she accomplished and the deliverable are also elaborated. These contribution were only possible thanks to DOE support of junior faculty research and their clear goal to promote research and innovations.
The CMS dataset bookkeeping service
NASA Astrophysics Data System (ADS)
Afaq, A.; Dolgert, A.; Guo, Y.; Jones, C.; Kosyakov, S.; Kuznetsov, V.; Lueking, L.; Riley, D.; Sekhri, V.
2008-07-01
The CMS Dataset Bookkeeping Service (DBS) has been developed to catalog all CMS event data from Monte Carlo and Detector sources. It provides the ability to identify MC or trigger source, track data provenance, construct datasets for analysis, and discover interesting data. CMS requires processing and analysis activities at various service levels and the DBS system provides support for localized processing or private analysis, as well as global access for CMS users at large. Catalog entries can be moved among the various service levels with a simple set of migration tools, thus forming a loose federation of databases. DBS is available to CMS users via a Python API, Command Line, and a Discovery web page interfaces. The system is built as a multi-tier web application with Java servlets running under Tomcat, with connections via JDBC to Oracle or MySQL database backends. Clients connect to the service through HTTP or HTTPS with authentication provided by GRID certificates and authorization through VOMS. DBS is an integral part of the overall CMS Data Management and Workflow Management systems.
ERIC Educational Resources Information Center
Terawaki, Yuki; Takahashi, Yuichi; Kodama, Yasushi; Yana, Kazuo
2011-01-01
This paper describes an integration of different Relational Database Management System (RDBMS) of two Course Management Systems (CMS) called Sakai and the Common Factory for Inspiration and Value in Education (CFIVE). First, when the service of CMS is provided campus-wide, the problems of user support, CMS operation and customization of CMS are…
NASA Technical Reports Server (NTRS)
Potter, William J.; Mitchell, Christine M.
1993-01-01
Historically, command management systems (CMS) have been large and expensive spacecraft-specific software systems that were costly to build, operate, and maintain. Current and emerging hardware, software, and user interface technologies may offer an opportunity to facilitate the initial formulation and design of a spacecraft-specific CMS as well as to develop a more generic CMS system. New technologies, in addition to a core CMS common to a range of spacecraft, may facilitate the training and enhance the efficiency of CMS operations. Current mission operations center (MOC) hardware and software include Unix workstations, the C/C++ programming languages, and an X window interface. This configuration provides the power and flexibility to support sophisticated and intelligent user interfaces that exploit state-of-the-art technologies in human-machine interaction, artificial intelligence, and software engineering. One of the goals of this research is to explore the extent to which technologies developed in the research laboratory can be productively applied in a complex system such as spacecraft command management. Initial examination of some of these issues in CMS design and operation suggests that application of technologies such as intelligent planning, case-based reasoning, human-machine systems design and analysis tools (e.g., operator and designer models), and human-computer interaction tools (e.g., graphics, visualization, and animation) may provide significant savings in the design, operation, and maintenance of the CMS for a specific spacecraft as well as continuity for CMS design and development across spacecraft. The first six months of this research saw a broad investigation by Georgia Tech researchers into the function, design, and operation of current and planned command management systems at Goddard Space Flight Center. As the first step, the researchers attempted to understand the current and anticipated horizons of command management systems at Goddard. Preliminary results are given on CMS commonalities and causes of low re-use, and methods are proposed to facilitate increased re-use.
42 CFR 488.68 - State Agency responsibilities for OASIS collection and data base requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... operating the OASIS system: (a) Establish and maintain an OASIS database. The State agency or other entity designated by CMS must— (1) Use a standard system developed or approved by CMS to collect, store, and analyze..., system back-up, and monitoring the status of the database; and (3) Obtain CMS approval before modifying...
2015-11-04
Coastal Inlets Research Program Coastal Modeling System The work unit develops the Coastal Modeling System ( CMS ) and conducts basic research to...further understanding of sediment transport under mixed oceanic and atmospheric forcing. The CMS is a suite of coupled two-dimensional numerical...models for simulations of waves, hydrodynamics, salinity and sediment transport, and morphology change. The CMS was identified by the USACE Hydraulics
Raschke, Robert A; Groves, Robert H; Khurana, Hargobind S; Nikhanj, Nidhi; Utter, Ethel; Hartling, Didi; Stoffer, Brenda; Nunn, Kristina; Tryon, Shona; Bruner, Michelle; Calleja, Maria; Curry, Steven C
2017-01-01
Sepsis is a leading cause of mortality and morbidity in hospitalised patients. The Centers for Medicare and Medicaid Services (CMS) mandated that US hospitals report sepsis bundle compliance rate as a quality process measure in October 2015. The specific aim of our study was to improve the CMS sepsis bundle compliance rate from 30% to 40% across 20 acute care hospitals in our healthcare system within 1 year. The study included all adult inpatients with sepsis sampled according to CMS specifications from October 2015 to September 2016. The CMS sepsis bundle compliance rate was tracked monthly using statistical process control charting. A baseline rate of 28.5% with 99% control limits was established. We implemented multiple interventions including computerised decision support systems (CDSSs) to increase compliance with the most commonly missing bundle elements. Compliance reached 42% (99% statistical process control limits 18.4%-38.6%) as CDSS was implemented system-wide, but this improvement was not sustained after CMS changed specifications of the outcome measure. Difficulties encountered elucidate shortcomings of our study methodology and of the CMS sepsis bundle compliance rate as a quality process measure.
The Archive Solution for Distributed Workflow Management Agents of the CMS Experiment at LHC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuznetsov, Valentin; Fischer, Nils Leif; Guo, Yuyi
The CMS experiment at the CERN LHC developed the Workflow Management Archive system to persistently store unstructured framework job report documents produced by distributed workflow management agents. In this paper we present its architecture, implementation, deployment, and integration with the CMS and CERN computing infrastructures, such as central HDFS and Hadoop Spark cluster. The system leverages modern technologies such as a document oriented database and the Hadoop eco-system to provide the necessary flexibility to reliably process, store, and aggregatemore » $$\\mathcal{O}$$(1M) documents on a daily basis. We describe the data transformation, the short and long term storage layers, the query language, along with the aggregation pipeline developed to visualize various performance metrics to assist CMS data operators in assessing the performance of the CMS computing system.« less
The Archive Solution for Distributed Workflow Management Agents of the CMS Experiment at LHC
Kuznetsov, Valentin; Fischer, Nils Leif; Guo, Yuyi
2018-03-19
The CMS experiment at the CERN LHC developed the Workflow Management Archive system to persistently store unstructured framework job report documents produced by distributed workflow management agents. In this paper we present its architecture, implementation, deployment, and integration with the CMS and CERN computing infrastructures, such as central HDFS and Hadoop Spark cluster. The system leverages modern technologies such as a document oriented database and the Hadoop eco-system to provide the necessary flexibility to reliably process, store, and aggregatemore » $$\\mathcal{O}$$(1M) documents on a daily basis. We describe the data transformation, the short and long term storage layers, the query language, along with the aggregation pipeline developed to visualize various performance metrics to assist CMS data operators in assessing the performance of the CMS computing system.« less
CMS Centres Worldwide - a New Collaborative Infrastructure
NASA Astrophysics Data System (ADS)
Taylor, Lucas
2011-12-01
The CMS Experiment at the LHC has established a network of more than fifty inter-connected "CMS Centres" at CERN and in institutes in the Americas, Asia, Australasia, and Europe. These facilities are used by people doing CMS detector and computing grid operations, remote shifts, data quality monitoring and analysis, as well as education and outreach. We present the computing, software, and collaborative tools and videoconferencing systems. These include permanently running "telepresence" video links (hardware-based H.323, EVO and Vidyo), Webcasts, and generic Web tools such as CMS-TV for broadcasting live monitoring and outreach information. Being Web-based and experiment-independent, these systems could easily be extended to other organizations. We describe the experiences of using CMS Centres Worldwide in the CMS data-taking operations as well as for major media events with several hundred TV channels, radio stations, and many more press journalists simultaneously around the world.
47 CFR 10.230 - New CMS providers participation in CMAS.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false New CMS providers participation in CMAS. 10.230 Section 10.230 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.230 New CMS providers participation in CMAS...
The CMS dataset bookkeeping service
DOE Office of Scientific and Technical Information (OSTI.GOV)
Afaq, Anzar,; /Fermilab; Dolgert, Andrew
2007-10-01
The CMS Dataset Bookkeeping Service (DBS) has been developed to catalog all CMS event data from Monte Carlo and Detector sources. It provides the ability to identify MC or trigger source, track data provenance, construct datasets for analysis, and discover interesting data. CMS requires processing and analysis activities at various service levels and the DBS system provides support for localized processing or private analysis, as well as global access for CMS users at large. Catalog entries can be moved among the various service levels with a simple set of migration tools, thus forming a loose federation of databases. DBS ismore » available to CMS users via a Python API, Command Line, and a Discovery web page interfaces. The system is built as a multi-tier web application with Java servlets running under Tomcat, with connections via JDBC to Oracle or MySQL database backends. Clients connect to the service through HTTP or HTTPS with authentication provided by GRID certificates and authorization through VOMS. DBS is an integral part of the overall CMS Data Management and Workflow Management systems.« less
Exploiting analytics techniques in CMS computing monitoring
NASA Astrophysics Data System (ADS)
Bonacorsi, D.; Kuznetsov, V.; Magini, N.; Repečka, A.; Vaandering, E.
2017-10-01
The CMS experiment has collected an enormous volume of metadata about its computing operations in its monitoring systems, describing its experience in operating all of the CMS workflows on all of the Worldwide LHC Computing Grid Tiers. Data mining efforts into all these information have rarely been done, but are of crucial importance for a better understanding of how CMS did successful operations, and to reach an adequate and adaptive modelling of the CMS operations, in order to allow detailed optimizations and eventually a prediction of system behaviours. These data are now streamed into the CERN Hadoop data cluster for further analysis. Specific sets of information (e.g. data on how many replicas of datasets CMS wrote on disks at WLCG Tiers, data on which datasets were primarily requested for analysis, etc) were collected on Hadoop and processed with MapReduce applications profiting of the parallelization on the Hadoop cluster. We present the implementation of new monitoring applications on Hadoop, and discuss the new possibilities in CMS computing monitoring introduced with the ability to quickly process big data sets from mulltiple sources, looking forward to a predictive modeling of the system.
NASA Astrophysics Data System (ADS)
Zhang, G.; Ganguly, S.; Saatchi, S. S.; Hagen, S. C.; Harris, N.; Yu, Y.; Nemani, R. R.
2013-12-01
Spatial and temporal patterns of forest disturbance and regrowth processes are key for understanding aboveground terrestrial vegetation biomass and carbon stocks at regional-to-continental scales. The NASA Carbon Monitoring System (CMS) program seeks key input datasets, especially information related to impacts due to natural/man-made disturbances in forested landscapes of Conterminous U.S. (CONUS), that would reduce uncertainties in current carbon stock estimation and emission models. This study provides a end-to-end forest disturbance detection framework based on pixel time series analysis from MODIS (Moderate Resolution Imaging Spectroradiometer) and Landsat surface spectral reflectance data. We applied the BFAST (Breaks for Additive Seasonal and Trend) algorithm to the Normalized Difference Vegetation Index (NDVI) data for the time period from 2000 to 2011. A harmonic seasonal model was implemented in BFAST to decompose the time series to seasonal and interannual trend components in order to detect abrupt changes in magnitude and direction of these components. To apply the BFAST for whole CONUS, we built a parallel computing setup for processing massive time-series data using the high performance computing facility of the NASA Earth Exchange (NEX). In the implementation process, we extracted the dominant deforestation events from the magnitude of abrupt changes in both seasonal and interannual components, and estimated dates for corresponding deforestation events. We estimated the recovery rate for deforested regions through regression models developed between NDVI values and time since disturbance for all pixels. A similar implementation of the BFAST algorithm was performed over selected Landsat scenes (all Landsat cloud free data was used to generate NDVI from atmospherically corrected spectral reflectances) to demonstrate the spatial coherence in retrieval layers between MODIS and Landsat. In future, the application of this largely parallel disturbance detection setup will facilitate large scale processing and wall-to-wall mapping of forest disturbance and regrowth of Landsat data for the whole of CONUS. This exercise will aid in improving the present capabilities of the NASA CMS effort in reducing uncertainties in national-level estimates of biomass and carbon stocks.
NASA Astrophysics Data System (ADS)
Acharya, S.; Adamová, D.; Adolfsson, J.; Aggarwal, M. M.; AglieriRinella, G.; Agnello, M.; Agrawal, N.; Ahammed, Z.; Ahmad, N.; Ahn, S. U.; Aiola, S.; Akindinov, A.; Alam, S. N.; Alba, J. L. B.; Albuquerque, D. S. D.; Aleksandrov, D.; Alessandro, B.; AlfaroMolina, R.; Alici, A.; Alkin, A.; Alme, J.; Alt, T.; Altenkamper, L.; Altsybeev, I.; Alves GarciaPrado, C.; An, M.; Andrei, C.; Andreou, D.; Andrews, H. A.; Andronic, A.; Anguelov, V.; Anson, C.; Antičić, T.; Antinori, F.; Antonioli, P.; Anwar, R.; Aphecetche, L.; Appelshäuser, H.; Arcelli, S.; Arnaldi, R.; Arnold, O. W.; Arsene, I. C.; Arslandok, M.; Audurier, B.; Augustinus, A.; Averbeck, R.; Azmi, M. D.; Badalà, A.; Baek, Y. W.; Bagnasco, S.; Bailhache, R.; Bala, R.; Baldisseri, A.; Ball, M.; Baral, R. C.; Barbano, A. M.; Barbera, R.; Barile, F.; Barioglio, L.; Barnaföldi, G. G.; Barnby, L. S.; Barret, V.; Bartalini, P.; Barth, K.; Bartsch, E.; Basile, M.; Bastid, N.; Basu, S.; Bathen, B.; Batigne, G.; Batista Camejo, A.; Batyunya, B.; Batzing, P. C.; Bearden, I. G.; Beck, H.; Bedda, C.; Behera, N. K.; Belikov, I.; Bellini, F.; Bello Martinez, H.; Bellwied, R.; Beltran, L. G. E.; Belyaev, V.; Bencedi, G.; Beole, S.; Bercuci, A.; Berdnikov, Y.; Berenyi, D.; Bertens, R. A.; Berzano, D.; Betev, L.; Bhasin, A.; Bhat, I. R.; Bhati, A. K.; Bhattacharjee, B.; Bhom, J.; Bianchi, L.; Bianchi, N.; Bianchin, C.; Bielčík, J.; Bielčíková, J.; Bilandzic, A.; Biswas, R.; Biswas, S.; Blair, J. T.; Blau, D.; Blume, C.; Boca, G.; Bock, F.; Bogdanov, A.; Boldizsár, L.; Bombara, M.; Bonomi, G.; Bonora, M.; Book, J.; Borel, H.; Borissov, A.; Borri, M.; Botta, E.; Bourjau, C.; Braun-Munzinger, P.; Bregant, M.; Broker, T. A.; Browning, T. A.; Broz, M.; Brucken, E. J.; Bruna, E.; Bruno, G. E.; Budnikov, D.; Buesching, H.; Bufalino, S.; Buhler, P.; Buncic, P.; Busch, O.; Buthelezi, Z.; Butt, J. B.; Buxton, J. T.; Cabala, J.; Caffarri, D.; Caines, H.; Caliva, A.; Calvo Villar, E.; Camerini, P.; Capon, A. A.; Carena, F.; Carena, W.; Carnesecchi, F.; Castillo Castellanos, J.; Castro, A. J.; Casula, E. A. R.; Ceballos Sanchez, C.; Cerello, P.; Chandra, S.; Chang, B.; Chapeland, S.; Chartier, M.; Charvet, J. L.; Chattopadhyay, S.; Chattopadhyay, S.; Chauvin, A.; Cherney, M.; Cheshkov, C.; Cheynis, B.; Chibante Barroso, V.; Chinellato, D. D.; Cho, S.; Chochula, P.; Choi, K.; Chojnacki, M.; Choudhury, S.; Chowdhury, T.; Christakoglou, P.; Christensen, C. H.; Christiansen, P.; Chujo, T.; Chung, S. U.; Cicalo, C.; Cifarelli, L.; Cindolo, F.; Cleymans, J.; Colamaria, F.; Colella, D.; Collu, A.; Colocci, M.; Concas, M.; Conesa Balbastre, G.; Conesa del Valle, Z.; Connors, M. E.; Contreras, J. G.; Cormier, T. M.; Corrales Morales, Y.; Cortés Maldonado, I.; Cortese, P.; Cosentino, M. R.; Costa, F.; Costanza, S.; Crkovská, J.; Crochet, P.; Cuautle, E.; Cunqueiro, L.; Dahms, T.; Dainese, A.; Danisch, M. C.; Danu, A.; Das, D.; Das, I.; Das, S.; Dash, A.; Dash, S.; De, S.; De Caro, A.; de Cataldo, G.; de Conti, C.; de Cuveland, J.; De Falco, A.; De Gruttola, D.; De Marco, N.; De Pasquale, S.; De Souza, R. D.; Degenhardt, H. F.; Deisting, A.; Deloff, A.; Deplano, C.; Dhankher, P.; Di Bari, D.; Di Mauro, A.; Di Nezza, P.; Di Ruzza, B.; Diakonov, I.; Diaz Corchero, M. A.; Dietel, T.; Dillenseger, P.; Divià, R.; Djuvsland, Ø.; Dobrin, A.; Domenicis Gimenez, D.; Dönigus, B.; Dordic, O.; Doremalen, L. V. V.; Drozhzhova, T.; Dubey, A. K.; Dubla, A.; Ducroux, L.; Duggal, A. K.; Dupieux, P.; Ehlers, R. J.; Elia, D.; Endress, E.; Engel, H.; Epple, E.; Erazmus, B.; Erhardt, F.; Espagnon, B.; Esumi, S.; Eulisse, G.; Eum, J.; Evans, D.; Evdokimov, S.; Fabbietti, L.; Faivre, J.; Fantoni, A.; Fasel, M.; Feldkamp, L.; Feliciello, A.; Feofilov, G.; Ferencei, J.; FernándezTéllez, A.; Ferreiro, E. G.; Ferretti, A.; Festanti, A.; Feuillard, V. J. G.; Figiel, J.; Figueredo, M. A. S.; Filchagin, S.; Finogeev, D.; Fionda, F. M.; Fiore, E. M.; Floris, M.; Foertsch, S.; Foka, P.; Fokin, S.; Fragiacomo, E.; Francescon, A.; Francisco, A.; Frankenfeld, U.; Fronze, G. G.; Fuchs, U.; Furget, C.; Furs, A.; Fusco Girard, M.; Gaardhøje, J. J.; Gagliardi, M.; Gago, A. M.; Gajdosova, K.; Gallio, M.; Galvan, C. D.; Ganoti, P.; Gao, C.; Garabatos, C.; Garcia-Solis, E.; Garg, K.; Garg, P.; Gargiulo, C.; Gasik, P.; Gauger, E. F.; Gay Ducati, M. B.; Germain, M.; Ghosh, J.; Ghosh, P.; Ghosh, S. K.; Gianotti, P.; Giubellino, P.; Giubilato, P.; Gladysz-Dziadus, E.; Glässel, P.; GomézCoral, D. M.; Gomez Ramirez, A.; Gonzalez, A. S.; Gonzalez, V.; González-Zamora, P.; Gorbunov, S.; Görlich, L.; Gotovac, S.; Grabski, V.; Graczykowski, L. K.; Graham, K. L.; Greiner, L.; Grelli, A.; Grigoras, C.; Grigoriev, V.; Grigoryan, A.; Grigoryan, S.; Grion, N.; Gronefeld, J. M.; Grosa, F.; Grosse-Oetringhaus, J. F.; Grosso, R.; Gruber, L.; Guber, F.; Guernane, R.; Guerzoni, B.; Gulbrandsen, K.; Gunji, T.; Gupta, A.; Gupta, R.; Guzman, I. B.; Haake, R.; Hadjidakis, C.; Hamagaki, H.; Hamar, G.; Hamon, J. C.; Harris, J. W.; Harton, A.; Hasan, H.; Hatzifotiadou, D.; Hayashi, S.; Heckel, S. T.; Hellbär, E.; Helstrup, H.; Herghelegiu, A.; HerreraCorral, G.; Herrmann, F.; Hess, B. A.; Hetland, K. F.; Hillemanns, H.; Hills, C.; Hippolyte, B.; Hladky, J.; Hohlweger, B.; Horak, D.; Hornung, S.; Hosokawa, R.; Hristov, P.; Hughes, C.; Humanic, T. J.; Hussain, N.; Hussain, T.; Hutter, D.; Hwang, D. S.; Iga Buitron, S. A.; Ilkaev, R.; Inaba, M.; Ippolitov, M.; Irfan, M.; Isakov, V.; Ivanov, M.; Ivanov, V.; Izucheev, V.; Jacak, B.; Jacazio, N.; Jachołkowski, A.; Jacobs, P. M.; Jadhav, M. B.; Jadlovska, S.; Jadlovsky, J.; Jaelani, S.; Jahnke, C.; Jakubowska, M. J.; Janik, M. A.; Jayarathna, P. H. S. Y.; Jena, C.; Jena, S.; Jeric, M.; Jimenez Bustamante, R. T.; Jones, P. G.; Jusko, A.; Kalinak, P.; Kalweit, A.; Kang, J. H.; Kaplin, V.; Kar, S.; Karasu Uysal, A.; Karavichev, O.; Karavicheva, T.; Karayan, L.; Karpechev, E.; Kebschull, U.; Keidel, R.; Keijdener, D. L. D.; Keil, M.; Ketzer, B.; Khan, P.; Khan, S. A.; Khanzadeev, A.; Kharlov, Y.; Khatun, A.; Khuntia, A.; Kielbowicz, M. M.; Kileng, B.; Kim, D.; Kim, D. W.; Kim, D. J.; Kim, H.; Kim, J. S.; Kim, J.; Kim, M.; Kim, M.; Kim, S.; Kim, T.; Kirsch, S.; Kisel, I.; Kiselev, S.; Kisiel, A.; Kiss, G.; Klay, J. L.; Klein, C.; Klein, J.; Klein-Bösing, C.; Klewin, S.; Kluge, A.; Knichel, M. L.; Knospe, A. G.; Kobdaj, C.; Kofarago, M.; Kollegger, T.; Kolojvari, A.; Kondratiev, V.; Kondratyeva, N.; Kondratyuk, E.; Konevskikh, A.; Konyushikhin, M.; Kopcik, M.; Kour, M.; Kouzinopoulos, C.; Kovalenko, O.; Kovalenko, V.; Kowalski, M.; Koyithatta Meethaleveedu, G.; Králik, I.; Kravčáková, A.; Krivda, M.; Krizek, F.; Kryshen, E.; Krzewicki, M.; Kubera, A. M.; Kučera, V.; Kuhn, C.; Kuijer, P. G.; Kumar, A.; Kumar, J.; Kumar, L.; Kumar, S.; Kundu, S.; Kurashvili, P.; Kurepin, A.; Kurepin, A. B.; Kuryakin, A.; Kushpil, S.; Kweon, M. J.; Kwon, Y.; La Pointe, S. L.; La Rocca, P.; Lagana Fernandes, C.; Lai, Y. S.; Lakomov, I.; Langoy, R.; Lapidus, K.; Lara, C.; Lardeux, A.; Lattuca, A.; Laudi, E.; Lavicka, R.; Lazaridis, L.; Lea, R.; Leardini, L.; Lee, S.; Lehas, F.; Lehner, S.; Lehrbach, J.; Lemmon, R. C.; Lenti, V.; Leogrande, E.; León Monzón, I.; Lévai, P.; Li, S.; Li, X.; Lien, J.; Lietava, R.; Lim, B.; Lindal, S.; Lindenstruth, V.; Lindsay, S. W.; Lippmann, C.; Lisa, M. A.; Litichevskyi, V.; Ljunggren, H. M.; Llope, W. J.; Lodato, D. F.; Loenne, P. I.; Loginov, V.; Loizides, C.; Loncar, P.; Lopez, X.; López Torres, E.; Lowe, A.; Luettig, P.; Lunardon, M.; Luparello, G.; Lupi, M.; Lutz, T. H.; Maevskaya, A.; Mager, M.; Mahajan, S.; Mahmood, S. M.; Maire, A.; Majka, R. D.; Malaev, M.; Malinina, L.; Mal'Kevich, D.; Malzacher, P.; Mamonov, A.; Manko, V.; Manso, F.; Manzari, V.; Mao, Y.; Marchisone, M.; Mareš, J.; Margagliotti, G. V.; Margotti, A.; Margutti, J.; Marín, A.; Markert, C.; Marquard, M.; Martin, N. A.; Martinengo, P.; Martinez, J. A. L.; Martínez, M. I.; Martínez García, G.; Martinez Pedreira, M.; Mas, A.; Masciocchi, S.; Masera, M.; Masoni, A.; Masson, E.; Mastroserio, A.; Mathis, A. M.; Matyja, A.; Mayer, C.; Mazer, J.; Mazzilli, M.; Mazzoni, M. A.; Meddi, F.; Melikyan, Y.; Menchaca-Rocha, A.; Meninno, E.; Mercado Pérez, J.; Meres, M.; Mhlanga, S.; Miake, Y.; Mieskolainen, M. M.; Mihaylov, D.; Mihaylov, D. L.; Milano, L.; Milosevic, J.; Mischke, A.; Mishra, A. N.; Miśkowiec, D.; Mitra, J.; Mitu, C. M.; Mohammadi, N.; Mohanty, B.; Mohisin Khan, M.; Montes, E.; Moreira De Godoy, D. A.; Moreno, L. A. P.; Moretto, S.; Morreale, A.; Morsch, A.; Muccifora, V.; Mudnic, E.; Mühlheim, D.; Muhuri, S.; Mukherjee, M.; Mulligan, J. D.; Munhoz, M. G.; Münning, K.; Munzer, R. H.; Murakami, H.; Murray, S.; Musa, L.; Musinsky, J.; Myers, C. J.; Myrcha, J. W.; Naik, B.; Nair, R.; Nandi, B. K.; Nania, R.; Nappi, E.; Narayan, A.; Naru, M. U.; Natal daLuz, H.; Nattrass, C.; Navarro, S. R.; Nayak, K.; Nayak, R.; Nayak, T. K.; Nazarenko, S.; Nedosekin, A.; Negrao De Oliveira, R. A.; Nellen, L.; Nesbo, S. V.; Ng, F.; Nicassio, M.; Niculescu, M.; Niedziela, J.; Nielsen, B. S.; Nikolaev, S.; Nikulin, S.; Nikulin, V.; Nobuhiro, A.; Noferini, F.; Nomokonov, P.; Nooren, G.; Noris, J. C. C.; Norman, J.; Nyanin, A.; Nystrand, J.; Oeschler, H.; Oh, S.; Ohlson, A.; Okubo, T.; Olah, L.; Oleniacz, J.; Oliveira Da Silva, A. C.; Oliver, M. H.; Onderwaater, J.; Oppedisano, C.; Orava, R.; Oravec, M.; Ortiz Velasquez, A.; Oskarsson, A.; Otwinowski, J.; Oyama, K.; Pachmayer, Y.; Pacik, V.; Pagano, D.; Pagano, P.; Paić, G.; Palni, P.; Pan, J.; Pandey, A. K.; Panebianco, S.; Papikyan, V.; Pappalardo, G. S.; Pareek, P.; Park, J.; Parmar, S.; Passfeld, A.; Pathak, S. P.; Paticchio, V.; Patra, R. N.; Paul, B.; Pei, H.; Peitzmann, T.; Peng, X.; Pereira, L. G.; Pereira Da Costa, H.; Peresunko, D.; Perez Lezama, E.; Peskov, V.; Pestov, Y.; Petráček, V.; Petrov, V.; Petrovici, M.; Petta, C.; Pezzi, R. P.; Piano, S.; Pikna, M.; Pillot, P.; Pimentel, L. O. D. L.; Pinazza, O.; Pinsky, L.; Piyarathna, D. B.; Płoskoń, M.; Planinic, M.; Pliquett, F.; Pluta, J.; Pochybova, S.; Podesta-Lerma, P. L. M.; Poghosyan, M. G.; Polichtchouk, B.; Poljak, N.; Poonsawat, W.; Pop, A.; Poppenborg, H.; Porteboeuf-Houssais, S.; Porter, J.; Pozdniakov, V.; Prasad, S. K.; Preghenella, R.; Prino, F.; Pruneau, C. A.; Pshenichnov, I.; Puccio, M.; Puddu, G.; Pujahari, P.; Punin, V.; Putschke, J.; Rachevski, A.; Raha, S.; Rajput, S.; Rak, J.; Rakotozafindrabe, A.; Ramello, L.; Rami, F.; Rana, D. B.; Raniwala, R.; Raniwala, S.; Räsänen, S. S.; Rascanu, B. T.; Rathee, D.; Ratza, V.; Ravasenga, I.; Read, K. F.; Redlich, K.; Rehman, A.; Reichelt, P.; Reidt, F.; Ren, X.; Renfordt, R.; Reolon, A. R.; Reshetin, A.; Reygers, K.; Riabov, V.; Ricci, R. A.; Richert, T.; Richter, M.; Riedler, P.; Riegler, W.; Riggi, F.; Ristea, C.; Rodríguez Cahuantzi, M.; Røed, K.; Rogochaya, E.; Rohr, D.; Röhrich, D.; Rokita, P. S.; Ronchetti, F.; Rosnet, P.; Rossi, A.; Rotondi, A.; Roukoutakis, F.; Roy, A.; Roy, C.; Roy, P.; Rubio Montero, A. J.; Rueda, O. V.; Rui, R.; Russo, R.; Rustamov, A.; Ryabinkin, E.; Ryabov, Y.; Rybicki, A.; Saarinen, S.; Sadhu, S.; Sadovsky, S.; Šafařík, K.; Saha, S. K.; Sahlmuller, B.; Sahoo, B.; Sahoo, P.; Sahoo, R.; Sahoo, S.; Sahu, P. K.; Saini, J.; Sakai, S.; Saleh, M. A.; Salzwedel, J.; Sambyal, S.; Samsonov, V.; Sandoval, A.; Sarkar, D.; Sarkar, N.; Sarma, P.; Sas, M. H. P.; Scapparone, E.; Scarlassara, F.; Scharenberg, R. P.; Scheid, H. S.; Schiaua, C.; Schicker, R.; Schmidt, C.; Schmidt, H. R.; Schmidt, M. O.; Schmidt, M.; Schuchmann, S.; Schukraft, J.; Schutz, Y.; Schwarz, K.; Schweda, K.; Scioli, G.; Scomparin, E.; Scott, R.; Šefčík, M.; Seger, J. E.; Sekiguchi, Y.; Sekihata, D.; Selyuzhenkov, I.; Senosi, K.; Senyukov, S.; Serradilla, E.; Sett, P.; Sevcenco, A.; Shabanov, A.; Shabetai, A.; Shahoyan, R.; Shaikh, W.; Shangaraev, A.; Sharma, A.; Sharma, A.; Sharma, M.; Sharma, M.; Sharma, N.; Sheikh, A. I.; Shigaki, K.; Shou, Q.; Shtejer, K.; Sibiriak, Y.; Siddhanta, S.; Sielewicz, K. M.; Siemiarczuk, T.; Silvermyr, D.; Silvestre, C.; Simatovic, G.; Simonetti, G.; Singaraju, R.; Singh, R.; Singhal, V.; Sinha, T.; Sitar, B.; Sitta, M.; Skaali, T. B.; Slupecki, M.; Smirnov, N.; Snellings, R. J. M.; Snellman, T. W.; Song, J.; Song, M.; Soramel, F.; Sorensen, S.; Sozzi, F.; Spiriti, E.; Sputowska, I.; Srivastava, B. K.; Stachel, J.; Stan, I.; Stankus, P.; Stenlund, E.; Stocco, D.; Strmen, P.; Suaide, A. A. P.; Sugitate, T.; Suire, C.; Suleymanov, M.; Suljic, M.; Sultanov, R.; Šumbera, M.; Sumowidagdo, S.; Suzuki, K.; Swain, S.; Szabo, A.; Szarka, I.; Szczepankiewicz, A.; Tabassam, U.; Takahashi, J.; Tambave, G. J.; Tanaka, N.; Tarhini, M.; Tariq, M.; Tarzila, M. G.; Tauro, A.; Tejeda Muñoz, G.; Telesca, A.; Terasaki, K.; Terrevoli, C.; Teyssier, B.; Thakur, D.; Thakur, S.; Thomas, D.; Tieulent, R.; Tikhonov, A.; Timmins, A. R.; Toia, A.; Tripathy, S.; Trogolo, S.; Trombetta, G.; Tropp, L.; Trubnikov, V.; Trzaska, W. H.; Trzeciak, B. A.; Tsuji, T.; Tumkin, A.; Turrisi, R.; Tveter, T. S.; Ullaland, K.; Umaka, E. N.; Uras, A.; Usai, G. L.; Utrobicic, A.; Vala, M.; Van Der Maarel, J.; Van Hoorne, J. W.; van Leeuwen, M.; Vanat, T.; Vande Vyvre, P.; Varga, D.; Vargas, A.; Vargyas, M.; Varma, R.; Vasileiou, M.; Vasiliev, A.; Vauthier, A.; Vázquez Doce, O.; Vechernin, V.; Veen, A. M.; Velure, A.; Vercellin, E.; Vergara Limón, S.; Vernet, R.; Vértesi, R.; Vickovic, L.; Vigolo, S.; Viinikainen, J.; Vilakazi, Z.; Villalobos Baillie, O.; Villatoro Tello, A.; Vinogradov, A.; Vinogradov, L.; Virgili, T.; Vislavicius, V.; Vodopyanov, A.; Völkl, M. A.; Voloshin, K.; Voloshin, S. A.; Volpe, G.; von Haller, B.; Vorobyev, I.; Voscek, D.; Vranic, D.; Vrláková, J.; Wagner, B.; Wagner, J.; Wang, H.; Wang, M.; Watanabe, D.; Watanabe, Y.; Weber, M.; Weber, S. G.; Weiser, D. F.; Wenzel, S. C.; Wessels, J. P.; Westerhoff, U.; Whitehead, A. M.; Wiechula, J.; Wikne, J.; Wilk, G.; Wilkinson, J.; Willems, G. A.; Williams, M. C. S.; Willsher, E.; Windelband, B.; Witt, W. E.; Yalcin, S.; Yamakawa, K.; Yang, P.; Yano, S.; Yin, Z.; Yokoyama, H.; Yoo, I.-K.; Yoon, J. H.; Yurchenko, V.; Zaccolo, V.; Zaman, A.; Zampolli, C.; Zanoli, H. J. C.; Zardoshti, N.; Zarochentsev, A.; Závada, P.; Zaviyalov, N.; Zbroszczyk, H.; Zhalov, M.; Zhang, H.; Zhang, X.; Zhang, Y.; Zhang, C.; Zhang, Z.; Zhao, C.; Zhigareva, N.; Zhou, D.; Zhou, Y.; Zhou, Z.; Zhu, H.; Zhu, J.; Zhu, X.; Zichichi, A.; Zimmermann, A.; Zimmermann, M. B.; Zinovjev, G.; Zmeskal, J.; Zou, S.
2017-12-01
We present the charged-particle multiplicity distributions over a wide pseudorapidity range (- 3.4<η <5.0) for pp collisions at √{s}= 0.9, 7, and 8 TeV at the LHC. Results are based on information from the Silicon Pixel Detector and the Forward Multiplicity Detector of ALICE, extending the pseudorapidity coverage of the earlier publications and the high-multiplicity reach. The measurements are compared to results from the CMS experiment and to PYTHIA, PHOJET and EPOS LHC event generators, as well as IP-Glasma calculations.
Implementation of NASTRAN on the IBM/370 CMS operating system
NASA Technical Reports Server (NTRS)
Britten, S. S.; Schumacker, B.
1980-01-01
The NASA Structural Analysis (NASTRAN) computer program is operational on the IBM 360/370 series computers. While execution of NASTRAN has been described and implemented under the virtual storage operating systems of the IBM 370 models, the IBM 370/168 computer can also operate in a time-sharing mode under the virtual machine operating system using the Conversational Monitor System (CMS) subset. The changes required to make NASTRAN operational under the CMS operating system are described.
Development of Cytoplasmic Male Sterile IR24 and IR64 Using CW-CMS/Rf17 System.
Toriyama, Kinya; Kazama, Tomohiko
2016-12-01
A wild-abortive-type (WA) cytoplasmic male sterility (CMS) has been almost exclusively used for breeding three-line hybrid rice. Many indica cultivars are known to carry restorer genes for WA-CMS lines and cannot be used as maintainer lines. Especially elite indica cultivars IR24 and IR64 are known to be restorer lines for WA-CMS lines, and are used as male parents for hybrid seed production. If we develop CMS IR24 and CMS IR64, the combination of F1 pairs in hybrid rice breeding programs will be greatly broadened. For production of CMS lines and restorer lines of IR24 and IR64, we employed Chinese wild rice (CW)-type CMS/Restorer of fertility 17 (Rf17) system, in which fertility is restored by a single nuclear gene, Rf17. Successive backcrossing and marker-assisted selection of Rf17 succeeded to produce completely male sterile CMS lines and fully restored restorer lines of IR24 and IR64. CW-cytoplasm did not affect agronomic characteristics. Since IR64 is one of the most popular mega-varieties and used for breeding of many modern varieties, the CW-CMS line of IR64 will be useful for hybrid rice breeding.
Heng, Shuangping; Liu, Sansan; Xia, Chunxiu; Tang, HongYu; Xie, Fei; Fu, Tingdong; Wan, Zhengjie
2018-01-01
KEY MESSAGE: oxa CMS is a new cytoplasmic male sterility type in Brassica juncea. oxa CMS is a cytoplasmic male sterility (CMS) line that has been widely used in the production and cultivation of stem mustard in the southwestern China. In this study, different CMS-type specific mitochondrial markers were used to confirm that oxa CMS is distinct from the pol CMS, ogu CMS, nap CMS, hau CMS, tour CMS, Moricandia arvensis CMS, orf220-type CMS, etc., that have been previously reported in Brassica crops. Pollen grains of the oxa CMS line are sterile with a self-fertility rate of almost 0% and the sterility strain rate and sterility degree of oxa CMS is 100% due to a specific flower structure and flowering habit. Scanning electron microscopy revealed that most pollen grains in mature anthers of the oxa CMS line are empty, flat and deflated. Semi-thin section further showed that the abortive stage of anther development in oxa CMS is initiated at the late uninucleate stage. Abnormally vacuolated microspores caused male sterility in the oxa CMS line. This cytological study combined with marker-assisted selection showed that oxa CMS is a novel CMS type in stem mustard (Brassica juncea). Interestingly, the abortive stage of oxa CMS is later than those in other CMS types reported in Brassica crops, and there is no negative effect on the oxa CMS line growth period. This study demonstrated that this novel oxa CMS has a unique flower structure with sterile pollen grains at the late uninucleate stage. Our results may help to uncover the mechanism of oxa CMS in Brassica juncea.
Using the CMS threaded framework in a production environment
Jones, C. D.; Contreras, L.; Gartung, P.; ...
2015-12-23
During 2014, the CMS Offline and Computing Organization completed the necessary changes to use the CMS threaded framework in the full production environment. We will briefly discuss the design of the CMS Threaded Framework, in particular how the design affects scaling performance. We will then cover the effort involved in getting both the CMSSW application software and the workflow management system ready for using multiple threads for production. Finally, we will present metrics on the performance of the application and workflow system as well as the difficulties which were uncovered. As a result, we will end with CMS' plans formore » using the threaded framework to do production for LHC Run 2.« less
Exploiting Analytics Techniques in CMS Computing Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonacorsi, D.; Kuznetsov, V.; Magini, N.
The CMS experiment has collected an enormous volume of metadata about its computing operations in its monitoring systems, describing its experience in operating all of the CMS workflows on all of the Worldwide LHC Computing Grid Tiers. Data mining efforts into all these information have rarely been done, but are of crucial importance for a better understanding of how CMS did successful operations, and to reach an adequate and adaptive modelling of the CMS operations, in order to allow detailed optimizations and eventually a prediction of system behaviours. These data are now streamed into the CERN Hadoop data cluster formore » further analysis. Specific sets of information (e.g. data on how many replicas of datasets CMS wrote on disks at WLCG Tiers, data on which datasets were primarily requested for analysis, etc) were collected on Hadoop and processed with MapReduce applications profiting of the parallelization on the Hadoop cluster. We present the implementation of new monitoring applications on Hadoop, and discuss the new possibilities in CMS computing monitoring introduced with the ability to quickly process big data sets from mulltiple sources, looking forward to a predictive modeling of the system.« less
Tool-Use in a Content Management System: A Matter of Timing?
ERIC Educational Resources Information Center
Lust, Griet; Vandewaetere, Mieke; Elen, Jan; Clarebout, Geraldine
2014-01-01
Given the rising popularity of content management systems (CMSs) in higher education, we investigated how students use the available CMS tools, as well as whether the moment of using a CMS tool affects students' learning. This temporal dimension has been neglected in current research on CMS use. More insight into students' tool-use is…
Kim, Sangsung; Park, Hun-Jun; Byun, Jaemin; Cho, Kyu-Won; Saafir, Talib; Song, Ming-Ke; Yu, Shan Ping; Wagner, Mary; Bao, Gang; Yoon, Young-Sup
2013-01-01
Background While methods for generating cardiomyocytes (CMs) from pluripotent stem cells (PSCs) have been reported, current methods produce heterogeneous mixtures of CMs and non-CM cells. Here, we report an entirely novel system in which PSC-derived CMs are purified by CM-specific molecular beacons (MBs). MBs are nano-scale probes that emit a fluorescence signal when hybridized to target mRNAs. Method and Results Five MBs targeting mRNAs of either cardiac troponin T or myosin heavy chain 6/7 were generated. Among five MBs, a MB targeting myosin heavy chain 6/7 mRNA (MHC1-MB) identified up to 99% of HL-1 CMs, a mouse CM cell line, but < 3% of four non-CM cell types in flow cytometry analysis, indicating that MHC1-MB is specific for identifying CMs. We delivered MHC1-MB into cardiomyogenically differentiated PSCs through nucleofection. The detection rate of CMs was similar to the percentages of cardiac troponin T (TNNT2) or cardiac troponin I (TNNI3)-positive CMs, supporting the specificity of MBs. Finally, MHC1-MB-positive cells were FACS-sorted from mouse and human PSC differentiating cultures and ~97% cells expressed TNNT2- or TNNI3 determined by flow cytometry. These MB-based sorted cells maintained their CM characteristics verified by spontaneous beating, electrophysiologic studies, and expression of cardiac proteins. When transplanted in a myocardial infarction model, MB-based purified CMs improved cardiac function and demonstrated significant engraftment for 4 weeks without forming tumors. Conclusions We developed a novel CM selection system that allows production of highly purified CMs. These purified CMs and this system can be valuable for cell therapy and drug discovery. PMID:23995537
NASA Astrophysics Data System (ADS)
Kuznetsov, Valentin; Riley, Daniel; Afaq, Anzar; Sekhri, Vijay; Guo, Yuyi; Lueking, Lee
2010-04-01
The CMS experiment has implemented a flexible and powerful system enabling users to find data within the CMS physics data catalog. The Dataset Bookkeeping Service (DBS) comprises a database and the services used to store and access metadata related to CMS physics data. To this, we have added a generalized query system in addition to the existing web and programmatic interfaces to the DBS. This query system is based on a query language that hides the complexity of the underlying database structure by discovering the join conditions between database tables. This provides a way of querying the system that is simple and straightforward for CMS data managers and physicists to use without requiring knowledge of the database tables or keys. The DBS Query Language uses the ANTLR tool to build the input query parser and tokenizer, followed by a query builder that uses a graph representation of the DBS schema to construct the SQL query sent to underlying database. We will describe the design of the query system, provide details of the language components and overview of how this component fits into the overall data discovery system architecture.
Shu, Jinshuai; Liu, Yumei; Li, Zhansheng; Zhang, Lili; Fang, Zhiyuan; Yang, Limei; Zhuang, Mu; Zhang, Yangyong; Lv, Honghao
2016-01-01
Broccoli (Brassica oleracea var. italica) is an important commercial vegetable crop. As part of an efficient pollination system, cytoplasmic male sterility (CMS) has been widely used for broccoli hybrid production. Identifying the original sources of CMS in broccoli accessions has become an important part of broccoli breeding. In this study, the diversity of the CMS sources of 39 broccoli accessions, including 19 CMS lines and 20 hybrids, were analyzed using mitochondrial markers. All CMS accessions contained the ogu orf138-related DNA fragment and the key genes of nap CMS, pol CMS, and tour CMS were not detected. The 39 CMS accessions were divided into five groups using six orf138-related and two simple sequence repeat markers. We observed that ogu CMS R3 constituted 79.49% of the CMS sources. CMS6 and CMS26 were differentiated from the other accessions using a specific primer. CMS32 was distinguished from the other accessions based on a 78-nucleotide deletion at the same locus as the orf138-related sequence. When the coefficient was about 0.90, five CMS accessions (13CMS6, 13CMS23, 13CMS24, 13CMS37, and 13CMS39) exhibiting abnormal floral organs with poor seed setting were grouped together. The polymerase chain reaction amplification profiles for these five accessions differed from those of the other accessions. We identified eight useful molecular markers that can be used to detect CMS types during broccoli breeding. Our data also provide important information relevant to future studies on the possible origins and molecular mechanisms of CMS in broccoli.
Shu, Jinshuai; Liu, Yumei; Li, Zhansheng; Zhang, Lili; Fang, Zhiyuan; Yang, Limei; Zhuang, Mu; Zhang, Yangyong; Lv, Honghao
2016-01-01
Broccoli (Brassica oleracea var. italica) is an important commercial vegetable crop. As part of an efficient pollination system, cytoplasmic male sterility (CMS) has been widely used for broccoli hybrid production. Identifying the original sources of CMS in broccoli accessions has become an important part of broccoli breeding. In this study, the diversity of the CMS sources of 39 broccoli accessions, including 19 CMS lines and 20 hybrids, were analyzed using mitochondrial markers. All CMS accessions contained the ogu orf138-related DNA fragment and the key genes of nap CMS, pol CMS, and tour CMS were not detected. The 39 CMS accessions were divided into five groups using six orf138-related and two simple sequence repeat markers. We observed that ogu CMS R3 constituted 79.49% of the CMS sources. CMS6 and CMS26 were differentiated from the other accessions using a specific primer. CMS32 was distinguished from the other accessions based on a 78-nucleotide deletion at the same locus as the orf138-related sequence. When the coefficient was about 0.90, five CMS accessions (13CMS6, 13CMS23, 13CMS24, 13CMS37, and 13CMS39) exhibiting abnormal floral organs with poor seed setting were grouped together. The polymerase chain reaction amplification profiles for these five accessions differed from those of the other accessions. We identified eight useful molecular markers that can be used to detect CMS types during broccoli breeding. Our data also provide important information relevant to future studies on the possible origins and molecular mechanisms of CMS in broccoli. PMID:27446156
Marchand, Sandrine; Bouchene, Salim; de Monte, Michèle; Guilleminault, Laurent; Montharu, Jérôme; Cabrera, Maria; Grégoire, Nicolas; Gobin, Patrice; Diot, Patrice; Couet, William; Vecellio, Laurent
2015-10-01
The objective of this study was to compare two different nebulizers: Eflow rapid® and Pari LC star® by scintigraphy and PK modeling to simulate epithelial lining fluid concentrations from measured plasma concentrations, after nebulization of CMS in baboons. Three baboons received CMS by IV infusion and by 2 types of aerosols generators and colistin by subcutaneous infusion. Gamma imaging was performed after nebulisation to determine colistin distribution in lungs. Blood samples were collected during 9 h and colistin and CMS plasma concentrations were measured by LC-MS/MS. A population pharmacokinetic analysis was conducted and simulations were performed to predict lung concentrations after nebulization. Higher aerosol distribution into lungs was observed by scintigraphy, when CMS was nebulized with Pari LC® star than with Eflow Rapid® nebulizer. This observation was confirmed by the fraction of CMS deposited into the lung (respectively 3.5% versus 1.3%).CMS and colistin simulated concentrations in epithelial lining fluid were higher after using the Pari LC star® than the Eflow rapid® system. A limited fraction of CMS reaches lungs after nebulization, but higher colistin plasma concentrations were measured and higher intrapulmonary colistin concentrations were simulated with the Pari LC Star® than with the Eflow Rapid® system.
Spatial clustering of pixels of a multispectral image
Conger, James Lynn
2014-08-19
A method and system for clustering the pixels of a multispectral image is provided. A clustering system computes a maximum spectral similarity score for each pixel that indicates the similarity between that pixel and the most similar neighboring. To determine the maximum similarity score for a pixel, the clustering system generates a similarity score between that pixel and each of its neighboring pixels and then selects the similarity score that represents the highest similarity as the maximum similarity score. The clustering system may apply a filtering criterion based on the maximum similarity score so that pixels with similarity scores below a minimum threshold are not clustered. The clustering system changes the current pixel values of the pixels in a cluster based on an averaging of the original pixel values of the pixels in the cluster.
The Consensus Molecular Subtypes of Colorectal Cancer
Guinney, Justin; Dienstmann, Rodrigo; Wang, Xin; de Reyniès, Aurélien; Schlicker, Andreas; Soneson, Charlotte; Marisa, Laetitia; Roepman, Paul; Nyamundanda, Gift; Angelino, Paolo; Bot, Brian M.; Morris, Jeffrey S.; Simon, Iris M.; Gerster, Sarah; Fessler, Evelyn; de Sousa e Melo, Felipe; Missiaglia, Edoardo; Ramay, Hena; Barras, David; Homicsko, Krisztian; Maru, Dipen; Manyam, Ganiraju C.; Broom, Bradley; Boige, Valerie; Perez-Villamil, Beatriz; Laderas, Ted; Salazar, Ramon; Gray, Joe W.; Hanahan, Douglas; Tabernero, Josep; Bernards, Rene; Friend, Stephen H.; Laurent-Puig, Pierre; Medema, Jan Paul; Sadanandam, Anguraj; Wessels, Lodewyk; Delorenzi, Mauro; Kopetz, Scott; Vermeulen, Louis; Tejpar, Sabine
2015-01-01
Colorectal cancer (CRC) is a frequently lethal disease with heterogeneous outcomes and drug responses. To resolve inconsistencies among the reported gene expression–based CRC classifications and facilitate clinical translation, we formed an international consortium dedicated to large-scale data sharing and analytics across expert groups. We show marked interconnectivity between six independent classification systems coalescing into four consensus molecular subtypes (CMS) with distinguishing features: CMS1 (MSI Immune, 14%), hypermutated, microsatellite unstable, strong immune activation; CMS2 (Canonical, 37%), epithelial, chromosomally unstable, marked WNT and MYC signaling activation; CMS3 (Metabolic, 13%), epithelial, evident metabolic dysregulation; and CMS4 (Mesenchymal, 23%), prominent transforming growth factor β activation, stromal invasion, and angiogenesis. Samples with mixed features (13%) possibly represent a transition phenotype or intra-tumoral heterogeneity. We consider the CMS groups the most robust classification system currently available for CRC – with clear biological interpretability – and the basis for future clinical stratification and subtype–based targeted interventions. PMID:26457759
Chemical Inventory Management at NASA Lewis Research Center
NASA Technical Reports Server (NTRS)
Kraft, Shirley S.; Homan, Joseph R.; Bajorek, Michael J.; Dominguez, Manuel B.; Smith, Vanessa L.
1997-01-01
The Chemical Management System (CMS) is a client/server application developed with Power Builder and Sybase for the Lewis Research Center (LeRC). Power Builder is a client-server application development tool, Sybase is a Relational Database Management System. The entire LeRC community can access the CMS from any desktop environment. The multiple functions and benefits of the CMS are addressed.
The CMS High Level Trigger System: Experience and Future Development
NASA Astrophysics Data System (ADS)
Bauer, G.; Behrens, U.; Bowen, M.; Branson, J.; Bukowiec, S.; Cittolin, S.; Coarasa, J. A.; Deldicque, C.; Dobson, M.; Dupont, A.; Erhan, S.; Flossdorf, A.; Gigi, D.; Glege, F.; Gomez-Reino, R.; Hartl, C.; Hegeman, J.; Holzner, A.; Hwong, Y. L.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; O'Dell, V.; Orsini, L.; Paus, C.; Petrucci, A.; Pieri, M.; Polese, G.; Racz, A.; Raginel, O.; Sakulin, H.; Sani, M.; Schwick, C.; Shpakov, D.; Simon, S.; Spataru, A. C.; Sumorok, K.
2012-12-01
The CMS experiment at the LHC features a two-level trigger system. Events accepted by the first level trigger, at a maximum rate of 100 kHz, are read out by the Data Acquisition system (DAQ), and subsequently assembled in memory in a farm of computers running a software high-level trigger (HLT), which selects interesting events for offline storage and analysis at a rate of order few hundred Hz. The HLT algorithms consist of sequences of offline-style reconstruction and filtering modules, executed on a farm of 0(10000) CPU cores built from commodity hardware. Experience from the operation of the HLT system in the collider run 2010/2011 is reported. The current architecture of the CMS HLT, its integration with the CMS reconstruction framework and the CMS DAQ, are discussed in the light of future development. The possible short- and medium-term evolution of the HLT software infrastructure to support extensions of the HLT computing power, and to address remaining performance and maintenance issues, are discussed.
ERIC Educational Resources Information Center
Tsai, Yea-Ru
2015-01-01
This study illustrates a teaching model that utilizes a Blackboard (Bb) course management system (CMS) to support English writing instruction. It was implemented in a blended English research paper (RP) writing course, with specific learning resources and activities offered inside and outside the Bb CMS. A quasi-experimental study in which the…
Microchannel plate EUV detectors for the Extreme Ultraviolet Explorer
NASA Technical Reports Server (NTRS)
Siegmund, O. H. W.; Malina, R. F.; Coburn, K.; Werthimer, D.
1984-01-01
The design and operating characteristics of the prototype imaging microchannel plate (MCP) detector for the Extreme Ultraviolet Explorer (EUVE) Satellite are discussed. It is shown that this detector has achieved high position resolution performance (greater than 512 x 512 pixels) and has low (less than one percent) image distortion. In addition, the channel plate scheme used has tight pulse height distributions (less than 40 percent FWHM) for UV radiation and displays low (less than 0.2 cnt/sq cm-s) dark background counting rates. Work that has been done on EUV filters in relation to the envisaged filter and photocathode complement is also described.
Getting Started with Drupal WebCMS
Drupal WebCMS is accessible to EPA employees, and to onsite and offsite contractors. There are several roles in Drupal WebCMS and each allows a certain set of actions in the system. Users can have different roles in different web areas.
NASA Technical Reports Server (NTRS)
Mitchell, Christine M.
1998-01-01
Historically Command Management Systems (CMS) have been large, expensive, spacecraft-specific software systems that were costly to build, operate, and maintain. Current and emerging hardware, software, and user interface technologies may offer an opportunity to facilitate the initial formulation and design of a spacecraft-specific CMS as well as a to develop a more generic or a set of core components for CMS systems. Current MOC (mission operations center) hardware and software include Unix workstations, the C/C++ and Java programming languages, and X and Java window interfaces representations. This configuration provides the power and flexibility to support sophisticated systems and intelligent user interfaces that exploit state-of-the-art technologies in human-machine systems engineering, decision making, artificial intelligence, and software engineering. One of the goals of this research is to explore the extent to which technologies developed in the research laboratory can be productively applied in a complex system such as spacecraft command management. Initial examination of some of the issues in CMS design and operation suggests that application of technologies such as intelligent planning, case-based reasoning, design and analysis tools from a human-machine systems engineering point of view (e.g., operator and designer models) and human-computer interaction tools, (e.g., graphics, visualization, and animation), may provide significant savings in the design, operation, and maintenance of a spacecraft-specific CMS as well as continuity for CMS design and development across spacecraft with varying needs. The savings in this case is in software reuse at all stages of the software engineering process.
Code of Federal Regulations, 2011 CFR
2011-04-01
.... Congestion management means the application of strategies to improve system performance and reliability by... SYSTEMS Management Systems § 500.109 CMS. (a) For purposes of this part, congestion means the level at... management system or process is a systematic and regionally accepted approach for managing congestion that...
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Congestion management means the application of strategies to improve system performance and reliability by... SYSTEMS Management Systems § 500.109 CMS. (a) For purposes of this part, congestion means the level at... management system or process is a systematic and regionally accepted approach for managing congestion that...
Code of Federal Regulations, 2013 CFR
2013-04-01
... SYSTEMS Management Systems § 500.109 CMS. (a) For purposes of this part, congestion means the level at.... Congestion management means the application of strategies to improve system performance and reliability by... management system or process is a systematic and regionally accepted approach for managing congestion that...
Code of Federal Regulations, 2014 CFR
2014-04-01
... SYSTEMS Management Systems § 500.109 CMS. (a) For purposes of this part, congestion means the level at.... Congestion management means the application of strategies to improve system performance and reliability by... management system or process is a systematic and regionally accepted approach for managing congestion that...
Code of Federal Regulations, 2012 CFR
2012-04-01
... SYSTEMS Management Systems § 500.109 CMS. (a) For purposes of this part, congestion means the level at.... Congestion management means the application of strategies to improve system performance and reliability by... management system or process is a systematic and regionally accepted approach for managing congestion that...
The diverse use of clouds by CMS
Andronis, Anastasios; Bauer, Daniela; Chaze, Olivier; ...
2015-12-23
The resources CMS is using are increasingly being offered as clouds. In Run 2 of the LHC the majority of CMS CERN resources, both in Meyrin and at the Wigner Computing Centre, will be presented as cloud resources on which CMS will have to build its own infrastructure. This infrastructure will need to run all of the CMS workflows including: Tier 0, production and user analysis. In addition, the CMS High Level Trigger will provide a compute resource comparable in scale to the total offered by the CMS Tier 1 sites, when it is not running as part of themore » trigger system. During these periods a cloud infrastructure will be overlaid on this resource, making it accessible for general CMS use. Finally, CMS is starting to utilise cloud resources being offered by individual institutes and is gaining experience to facilitate the use of opportunistically available cloud resources. Lastly, we present a snap shot of this infrastructure and its operation at the time of the CHEP2015 conference.« less
Firoozmand, Lília Taddeo; Sanches, Andrea; Damaceno-Rodrigues, Nilsa Regina; Perez, Juliana Dinéia; Aragão, Danielle Sanches; Rosa, Rodolfo Mattar; Marcondes, Fernanda Klein; Casarini, Dulce Elena; Caldini, Elia Garcia; Cunha, Tatiana Sousa
2018-04-20
To test the effects of chronic-stress on the cardiovascular system, the model of chronic mild unpredictable stress (CMS) has been widely used. The CMS protocol consists of the random, intermittent, and unpredictable exposure of laboratory animals to a variety of stressors, during 3 consecutive weeks. In this study, we tested the hypothesis that exposure to the CMS protocol leads to left ventricle microcirculatory remodeling that can be attenuated by angiotensin II receptor blockade. Male Sprague-Dawley rats were randomly assigned into four groups: Control, Stress, Control + losartan, and Stress + losartan (N = 6, each group, losartan: 20 mg/kg/day). The rats were euthanized 15 days after CMS exposure, and blood samples and left ventricle were collected. Rats submitted to CMS presented increased glycemia, corticosterone, noradrenaline and adrenaline concentration, and losartan reduced the concentration of the circulating amines. Cardiac angiotensin II, measured by high-performance liquid chromatography (HPLC), was significantly increased in the CMS group, and losartan treatment reduced it, while angiotensin 1-7 was significantly higher in the CMS losartan-treated group as compared with CMS. Histological analysis, verified by transmission electron microscopy, showed that rats exposed to CMS presented increased perivascular collagen and losartan effectively prevented the development of this process. Hence, CMS induced a state of microvascular disease, with increased perivascular collagen deposition, that may be the trigger for further development of cardiovascular disease. In this case, CMS fibrosis is associated with increased production of catecholamines and with a disruption of renin-angiotensin system balance, which can be prevented by angiotensin II receptor blockade.
23 CFR 973.214 - Indian lands congestion management system (CMS).
Code of Federal Regulations, 2014 CFR
2014-04-01
... 23 Highways 1 2014-04-01 2014-04-01 false Indian lands congestion management system (CMS). 973.214... HIGHWAYS MANAGEMENT SYSTEMS PERTAINING TO THE BUREAU OF INDIAN AFFAIRS AND THE INDIAN RESERVATION ROADS PROGRAM Bureau of Indian Affairs Management Systems § 973.214 Indian lands congestion management system...
Shapiro, Stephen L.; Mani, Sudhindra; Atlas, Eugene L.; Cords, Dieter H. W.; Holbrook, Britt
1997-01-01
A data acquisition circuit for a particle detection system that allows for time tagging of particles detected by the system. The particle detection system screens out background noise and discriminate between hits from scattered and unscattered particles. The detection system can also be adapted to detect a wide variety of particle types. The detection system utilizes a particle detection pixel array, each pixel containing a back-biased PIN diode, and a data acquisition pixel array. Each pixel in the particle detection pixel array is in electrical contact with a pixel in the data acquisition pixel array. In response to a particle hit, the affected PIN diodes generate a current, which is detected by the corresponding data acquisition pixels. This current is integrated to produce a voltage across a capacitor, the voltage being related to the amount of energy deposited in the pixel by the particle. The current is also used to trigger a read of the pixel hit by the particle.
Proteomic Analysis of Male-Fertility Restoration in CMS Onion
USDA-ARS?s Scientific Manuscript database
The production of hybrid-onion seed is dependent on cytoplasmic-genic male sterility (CMS) systems. For the most commonly used CMS, male-sterile (S) cytoplasm interacts with a dominant allele at one nuclear male-fertility restoration locus (Ms) to condition male fertility. We are using proteomics ...
Wilpiszewska, Katarzyna; Spychaj, Tadeusz; Paździoch, Waldemar
2016-01-20
Preparation of novel high substituted carboxymethyl starch-based microparticles containing sodium montmorillonite (MMT) by crosslinking with Al(3+) was described. For preparing nanocomposite granules carboxymethyl starch (CMS) from native potato starch as well as CMS from amylopectin has been used. The hydrophilic CMS/MMT composite systems were used for herbicide, i.e. isoproturon encapsulation (ca. 75% encapsulation efficiency). The herbicide release rate from CMS/MMT composites in water was significantly reduced when compared to commercial isoproturon: 95% released after ca. 700 h and ca. 24h, respectively. Leaching in soil from composite systems was relatively slower than release in water. After a series of eight irrigations leached about 10% of isoproturon loaded. The CMS/MMT carriers could reduce the potential leaching of herbicide and beneficially reduce pollution of the environment. Copyright © 2015 Elsevier Ltd. All rights reserved.
MicroTCA-based Global Trigger Upgrade project for the CMS experiment at LHC
NASA Astrophysics Data System (ADS)
Rahbaran, B.; Arnold, B.; Bergauer, H.; Eichberger, M.; Rabady, D.
2011-12-01
The electronics of the first Level Global Trigger (GT) of CMS is the last stage of the Level-1 trigger system [1]. At LHC up to 40 million collisions of proton bunches occur every second, resulting in about 800 million proton collisions. The CMS Level-1 Global Trigger [1], a custom designed electronics system based on FPGA technology and the VMEbus system, performs a quick on-line analysis of each collision every 25 ns and decides whether to reject or to accept it for further analysis. The CMS trigger group of the Institute of High Energy Physics in Vienna (HEPHY) is involved in the Level-1 trigger of the CMS experiment at CERN. As part of the Trigger Upgrade, the Level-1 Global Trigger will be redesigned and implemented in MicroTCA based technology, which allows engineers to detect all possible faults on plug-in boards, in the power supply and in the cooling system. The upgraded Global Trigger will be designed to have the same basic categories of functions as the present GT, but will have more algorithms and more possibilities for combining trigger candidates. Additionally, reconfigurability and testability will be supported based on the next system generation.
42 CFR 433.119 - Conditions for reapproval; notice of decision.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Processing and Information Retrieval Systems § 433.119 Conditions for reapproval; notice of decision. (a) CMS... information: (1) CMS's decision to reduce FFP for system operations from 75 percent to 50 percent of...
42 CFR 433.119 - Conditions for reapproval; notice of decision.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Processing and Information Retrieval Systems § 433.119 Conditions for reapproval; notice of decision. (a) CMS... information: (1) CMS's decision to reduce FFP for system operations from 75 percent to 50 percent of...
42 CFR 433.119 - Conditions for reapproval; notice of decision.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Processing and Information Retrieval Systems § 433.119 Conditions for reapproval; notice of decision. (a) CMS... information: (1) CMS's decision to reduce FFP for system operations from 75 percent to 50 percent of...
42 CFR 433.119 - Conditions for reapproval; notice of decision.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Processing and Information Retrieval Systems § 433.119 Conditions for reapproval; notice of decision. (a) CMS... information: (1) CMS's decision to reduce FFP for system operations from 75 percent to 50 percent of...
1982-10-01
spent in preparing this document. 00. EXECUTIVE SUMMARY The O’Hare Runway Configuration Management System (CMS) is an interactive multi-user computer ...MITRE Washington’s Computer Center. Currently, CMS is housed in an IBM 4341 computer with VM/SP operating system. CMS employs the IBM’s Display...iV 0O, o 0 .r4L /~ wA 0U 00 00 0 w vi O’Hare, it will operate on a dedicated mini- computer which permits multi-tasking (that is, multiple users
76 FR 35444 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-17
... retrieval into the ASPEN system. The information needed to make certification decisions is available to CMS... Identifier CMS-1856 and CMS-1893] Agency Information Collection Activities: Submission for OMB Review... or any other aspect of this collection of information, including any of the following subjects: (1...
Huang, Jian-Zhong; E, Zhi-Guo; Zhang, Hua-Li; Shu, Qing-Yao
2014-12-01
The exploitation of male sterility systems has enabled the commercialization of heterosis in rice, with greatly increased yield and total production of this major staple food crop. Hybrid rice, which was adopted in the 1970s, now covers nearly 13.6 million hectares each year in China alone. Various types of cytoplasmic male sterility (CMS) and environment-conditioned genic male sterility (EGMS) systems have been applied in hybrid rice production. In this paper, recent advances in genetics, biochemistry, and molecular biology are reviewed with an emphasis on major male sterility systems in rice: five CMS systems, i.e., BT-, HL-, WA-, LD- and CW- CMS, and two EGMS systems, i.e., photoperiod- and temperature-sensitive genic male sterility (P/TGMS). The interaction of chimeric mitochondrial genes with nuclear genes causes CMS, which may be restored by restorer of fertility (Rf) genes. The PGMS, on the other hand, is conditioned by a non-coding RNA gene. A survey of the various CMS and EGMS lines used in hybrid rice production over the past three decades shows that the two-line system utilizing EGMS lines is playing a steadily larger role and TGMS lines predominate the current two-line system for hybrid rice production. The findings and experience gained during development and application of, and research on male sterility in rice not only advanced our understanding but also shed light on applications to other crops.
Case, Andrea L; Willis, John H
2008-05-01
Cytoplasmic male sterility (CMS) and nuclear fertility restoration (Rf) involves intergenomic coevolution. Although male-sterile phenotypes are rarely expressed in natural populations of angiosperms, CMS genes are thought to be common. The evolutionary dynamics of CMS/Rf systems are poorly understood, leaving gaps in our understanding of mechanisms and consequences of cytonuclear interactions. We characterized the molecular basis and geographic distribution of a CMS gene in Mimulus guttatus. We used outcrossing M. guttatus (with CMS and Rf) to self-fertilizing M. nasutus (lacking CMS and Rf) to generate hybrids segregating for CMS. Mitochondrial transcripts containing an essential gene (nad6) were perfectly associated with male sterility. The CMS mitotype was completely absent in M. nasutus, present in all genotypes collected from the original collection site, but in only two individuals from 34 other M. guttatus populations. This pattern suggests that the CMS likely originated at a single locality, spread to fixation within the population, but has not spread to other populations, indicating possible ecological or genetic constraints on dispersal of this CMS mitotype between populations. Extreme localization may be characteristic of CMS in hermaphroditic species, in contrast to geographically widespread mitotypes commonly found in gynodioecious species, and could directly contribute to hybrid incompatibilities in nature.
23 CFR 971.214 - Federal lands congestion management system (CMS).
Code of Federal Regulations, 2011 CFR
2011-04-01
... congestion management strategies; (v) Determine methods to monitor and evaluate the performance of the multi... Federal lands congestion management system (CMS). (a) For purposes of this section, congestion means the... for the transportation systems providing access to and within National Forests, as appropriate, that...
Bringing the CMS distributed computing system into scalable operations
NASA Astrophysics Data System (ADS)
Belforte, S.; Fanfani, A.; Fisk, I.; Flix, J.; Hernández, J. M.; Kress, T.; Letts, J.; Magini, N.; Miccio, V.; Sciabà, A.
2010-04-01
Establishing efficient and scalable operations of the CMS distributed computing system critically relies on the proper integration, commissioning and scale testing of the data and workload management tools, the various computing workflows and the underlying computing infrastructure, located at more than 50 computing centres worldwide and interconnected by the Worldwide LHC Computing Grid. Computing challenges periodically undertaken by CMS in the past years with increasing scale and complexity have revealed the need for a sustained effort on computing integration and commissioning activities. The Processing and Data Access (PADA) Task Force was established at the beginning of 2008 within the CMS Computing Program with the mandate of validating the infrastructure for organized processing and user analysis including the sites and the workload and data management tools, validating the distributed production system by performing functionality, reliability and scale tests, helping sites to commission, configure and optimize the networking and storage through scale testing data transfers and data processing, and improving the efficiency of accessing data across the CMS computing system from global transfers to local access. This contribution reports on the tools and procedures developed by CMS for computing commissioning and scale testing as well as the improvements accomplished towards efficient, reliable and scalable computing operations. The activities include the development and operation of load generators for job submission and data transfers with the aim of stressing the experiment and Grid data management and workload management systems, site commissioning procedures and tools to monitor and improve site availability and reliability, as well as activities targeted to the commissioning of the distributed production, user analysis and monitoring systems.
Reddemann, Antje; Horn, Renate
2018-03-11
Cytoplasmic male sterility (CMS) systems represent ideal mutants to study the role of mitochondria in pollen development. In sunflower, CMS PET2 also has the potential to become an alternative CMS source for commercial sunflower hybrid breeding. CMS PET2 originates from an interspecific cross of H. petiolaris and H. annuus as CMS PET1, but results in a different CMS mechanism. Southern analyses revealed differences for atp6 , atp9 and cob between CMS PET2, CMS PET1 and the male-fertile line HA89. A second identical copy of atp6 was present on an additional CMS PET2-specific fragment. In addition, the atp9 gene was duplicated. However, this duplication was followed by an insertion of 271 bp of unknown origin in the 5' coding region of the atp9 gene in CMS PET2, which led to the creation of two unique open reading frames orf288 and orf231 . The first 53 bp of orf288 are identical to the 5' end of atp9 . Orf231 consists apart from the first 3 bp, being part of the 271-bp-insertion, of the last 228 bp of atp9 . These CMS PET2-specific orfs are co-transcribed. All 11 editing sites of the atp9 gene present in orf231 are fully edited. The anther-specific reduction of the co-transcript in fertility-restored hybrids supports the involvement in male-sterility based on CMS PET2.
Matsuhashi, Aki; Nam, Kwangwoo; Kimura, Tsuyoshi; Kishida, Akio
2015-04-14
Microspheres using artificial or natural materials have been widely applied in the field of tissue engineering and drug delivery systems. Collagen is being widely used for microspheres because of its abundancy in the extracellular matrix (ECM), and its good biocompatibility. The purpose of this study is to establish the appropriate condition for preparing collagen microspheres (CMS) and fibrillized collagen microspheres (fCMS) using water-in-oil (W/O) emulsion. Collagen can be tailored to mimic the native cell environment possessing a similar microstructure to that of the ECM by conditioning the aqueous solution. We focused on the preparation of stable and injectable CMS and fCMS which is stable and would promote the healing response. Controlling the interfacial properties of hydrophilic-lipophilic balance (HLB), we obtained CMS and fCMS with various sizes and various morphologies. The microsphere prepared with wetting agents showed good microsphere formation, but too low or too high HLB value caused low yield and uncontrollable size distribution. The change in the surfactant amount and the rotor speed also affected the formation of the CMS and fCMS, where the low surfactant amount and fast rotor speed produced smaller CMS and fCMS. In the case of fCMS, the presence of NaCl made it possible to prepare stable fCMS without using any cross-linker due to fibrillogenesis and gelling of collagen molecules. The microstructure of fCMS was similar to that of the native tissue indicating that the fCMS would replicate its function in vivo.
Status and commissioning of the CMS experiment
NASA Astrophysics Data System (ADS)
Wulz, C.-E.
2008-05-01
The construction status of the CMS experiment at the Large Hadron Collider and strategies for commissioning the subdetectors, the magnet, the trigger and the data acquisition are described. The first operations of CMS as a unified system, using either cosmic rays or test data, and the planned activities until the startup of the LHC are presented.
USDA-ARS?s Scientific Manuscript database
The cytoplasmic male-sterility (CMS)/fertility-restoration system is important for hybrid sunflower (Helianthus annuus L.) seed production. Two novel alloplasmic CMSs, designated CMS GRO1 and CMS MAX3 with defective anthers, narrow disk florets with no swollen corolla, and short, narrow ray flowers,...
ERIC Educational Resources Information Center
Cote, Travis; Milliner, Brett
2015-01-01
E-learning has become a crucial component of most tertiary institution's education initiatives (Park, Lee, & Cheong, 2007) and core to most e-learning strategies is the institution's Content Management System (CMS). A CMS has the potential to enhance language courses by facilitating engagement with class content, providing students with…
Evolution of CMS workload management towards multicore job support
NASA Astrophysics Data System (ADS)
Pérez-Calero Yzquierdo, A.; Hernández, J. M.; Khan, F. A.; Letts, J.; Majewski, K.; Rodrigues, A. M.; McCrea, A.; Vaandering, E.
2015-12-01
The successful exploitation of multicore processor architectures is a key element of the LHC distributed computing system in the coming era of the LHC Run 2. High-pileup complex-collision events represent a challenge for the traditional sequential programming in terms of memory and processing time budget. The CMS data production and processing framework is introducing the parallel execution of the reconstruction and simulation algorithms to overcome these limitations. CMS plans to execute multicore jobs while still supporting singlecore processing for other tasks difficult to parallelize, such as user analysis. The CMS strategy for job management thus aims at integrating single and multicore job scheduling across the Grid. This is accomplished by employing multicore pilots with internal dynamic partitioning of the allocated resources, capable of running payloads of various core counts simultaneously. An extensive test programme has been conducted to enable multicore scheduling with the various local batch systems available at CMS sites, with the focus on the Tier-0 and Tier-1s, responsible during 2015 of the prompt data reconstruction. Scale tests have been run to analyse the performance of this scheduling strategy and ensure an efficient use of the distributed resources. This paper presents the evolution of the CMS job management and resource provisioning systems in order to support this hybrid scheduling model, as well as its deployment and performance tests, which will enable CMS to transition to a multicore production model for the second LHC run.
Evolution of CMS Workload Management Towards Multicore Job Support
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perez-Calero Yzquierdo, A.; Hernández, J. M.; Khan, F. A.
The successful exploitation of multicore processor architectures is a key element of the LHC distributed computing system in the coming era of the LHC Run 2. High-pileup complex-collision events represent a challenge for the traditional sequential programming in terms of memory and processing time budget. The CMS data production and processing framework is introducing the parallel execution of the reconstruction and simulation algorithms to overcome these limitations. CMS plans to execute multicore jobs while still supporting singlecore processing for other tasks difficult to parallelize, such as user analysis. The CMS strategy for job management thus aims at integrating single andmore » multicore job scheduling across the Grid. This is accomplished by employing multicore pilots with internal dynamic partitioning of the allocated resources, capable of running payloads of various core counts simultaneously. An extensive test programme has been conducted to enable multicore scheduling with the various local batch systems available at CMS sites, with the focus on the Tier-0 and Tier-1s, responsible during 2015 of the prompt data reconstruction. Scale tests have been run to analyse the performance of this scheduling strategy and ensure an efficient use of the distributed resources. This paper presents the evolution of the CMS job management and resource provisioning systems in order to support this hybrid scheduling model, as well as its deployment and performance tests, which will enable CMS to transition to a multicore production model for the second LHC run.« less
Challenging data and workload management in CMS Computing with network-aware systems
NASA Astrophysics Data System (ADS)
D, Bonacorsi; T, Wildish
2014-06-01
After a successful first run at the LHC, and during the Long Shutdown (LS1) of the accelerator, the workload and data management sectors of the CMS Computing Model are entering into an operational review phase in order to concretely assess area of possible improvements and paths to exploit new promising technology trends. In particular, since the preparation activities for the LHC start, the Networks have constantly been of paramount importance for the execution of CMS workflows, exceeding the original expectations - as from the MONARC model - in terms of performance, stability and reliability. The low-latency transfers of PetaBytes of CMS data among dozens of WLCG Tiers worldwide using the PhEDEx dataset replication system is an example of the importance of reliable Networks. Another example is the exploitation of WAN data access over data federations in CMS. A new emerging area of work is the exploitation of Intelligent Network Services, including also bandwidth on demand concepts. In this paper, we will review the work done in CMS on this, and the next steps.
A new information architecture, website and services for the CMS experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, Lucas; Rusack, Eleanor; Zemleris, Vidmantas
2012-01-01
The age and size of the CMS collaboration at the LHC means it now has many hundreds of inhomogeneous web sites and services, and hundreds of thousands of documents. We describe a major initiative to create a single coherent CMS internal and public web site. This uses the Drupal web Content Management System (now supported by CERN/IT) on top of a standard LAMP stack (Linux, Apache, MySQL, and php/perl). The new navigation, content and search services are coherently integrated with numerous existing CERN services (CDS, EDMS, Indico, phonebook, Twiki) as well as many CMS internal Web services. We describe themore » information architecture, the system design, implementation and monitoring, the document and content database, security aspects, and our deployment strategy, which ensured continual smooth operation of all systems at all times.« less
A new Information Architecture, Website and Services for the CMS Experiment
NASA Astrophysics Data System (ADS)
Taylor, Lucas; Rusack, Eleanor; Zemleris, Vidmantas
2012-12-01
The age and size of the CMS collaboration at the LHC means it now has many hundreds of inhomogeneous web sites and services, and hundreds of thousands of documents. We describe a major initiative to create a single coherent CMS internal and public web site. This uses the Drupal web Content Management System (now supported by CERN/IT) on top of a standard LAMP stack (Linux, Apache, MySQL, and php/perl). The new navigation, content and search services are coherently integrated with numerous existing CERN services (CDS, EDMS, Indico, phonebook, Twiki) as well as many CMS internal Web services. We describe the information architecture; the system design, implementation and monitoring; the document and content database; security aspects; and our deployment strategy, which ensured continual smooth operation of all systems at all times.
Kang, Lei; Li, Pengfei; Wang, Aifan; Ge, Xianhong; Li, Zaiyun
2017-01-01
A novel cytoplasmic male sterility (CMS) in Brassica napus (inap CMS) was selected from the somatic hybrid with Isatis indigotica (Chinese woad) by recurrent backcrossing. The male sterility was caused by the conversion of tetradynamous stamens into carpelloid structures with stigmatoid tissues at their tips and ovule-like tissues in the margins, and the two shorter stamens into filaments without anthers. The feminized development of the stamens resulted in the complete lack of pollen grains, which was stable in different years and environments. The pistils of inap CMS displayed normal morphology and good seed-set after pollinated by B. napus . Histological sections showed that the developmental alteration of the stamens initiated at the stage of stamen primordium differentiation. AFLP analysis of the nuclear genomic composition with 23 pairs of selective primers detected no woad DNA bands in inap CMS. Twenty out of 25 mitochondrial genes originated from I. indigotica , except for cox2-2 which was the recombinant between cox2 from woad and cox2-2 from rapeseed. The novel cox2-2 was transcribed in flower buds of inap CMS weakly and comparatively with the fertile B. napus addition line Me harboring one particular woad chromosome. The restorers of other autoplasmic and alloplasmic CMS systems in rapeseed failed to restore the fertility of inap CMS and the screening of B. napus wide resources found no fertility restoration variety, showing its distinct origin and the related mechanism of sterility. The reasons for the mitochondrial rearrangements and the breeding of the restorer for the novel CMS system were discussed.
Steeneveld, W; Tauer, L W; Hogeveen, H; Oude Lansink, A G J M
2012-12-01
Changing from a conventional milking system (CMS) to an automatic milking system (AMS) necessitates a new management approach and a corresponding change in labor tasks. Together with labor savings, AMS farms have been found to have higher capital costs, primarily because of higher maintenance costs and depreciation. Therefore, it is hypothesized that AMS farms differ from CMS farms in capital:labor ratio and possibly their technical efficiency, at least during a transition learning period. The current study used actual farm accounting data from dairy farms in the Netherlands with an AMS and a CMS to investigate the empirical substitution of capital for labor in the AMS farms and to determine if the technical efficiency of the AMS farms differed from the CMS farms. The technical efficiency estimates were obtained with data envelopment analysis. The 63 AMS farms and the 337 CMS farms in the data set did not differ in general farm characteristics such as the number of cows, number of hectares, and the amount of milk quota. Farms with AMS have significantly higher capital costs (€12.71 per 100 kg of milk) than CMS farms (€10.10 per 100 kg of milk). Total labor costs and net outputs were not significantly different between AMS and CMS farms. A clear substitution of capital for labor with the adoption of an AMS could not be observed. Although the AMS farms have a slightly lower technical efficiency (0.76) than the CMS farms (0.78), a significant difference in these estimates was not observed. This indicates that the farms were not different in their ability to use inputs (capital, labor, cows, and land) to produce outputs (total farm revenues). The technical efficiency of farms invested in an AMS in 2008 or earlier was not different from the farms invested in 2009 or 2010, indicating that a learning effect during the transition period was not observed. The results indicate that the economic performance of AMS and CMS farms are similar. What these results show is that other than higher capital costs, the use of AMS rather than a CMS does not affect farm efficiency and that the learning costs to use an AMS are not present as measured by any fall in technical efficiency. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Development of BEM for ceramic composites
NASA Technical Reports Server (NTRS)
Henry, D. P.; Banerjee, P. K.; Dargush, G. F.; Hopkins, D. A.; Goldberg, R. K.
1993-01-01
BEST-CMS (boundary element solution technology - composite modeling system) is an advanced engineering system for the micro-analysis of fiber composite structures. BEST-CMS is based upon the boundary element program BEST3D which was developed for NASA by Pratt and Whitney Aircraft and the State University of New York at Buffalo under contract NAS3-23697. BEST-CMS presently has the capabilities for elastostatic analysis, steady-state and transient heat transfer analysis, steady-state and transient concurrent thermoelastic analysis, and elastoplastic and creep analysis. The fibers are assumed to be perfectly bonded to the composite matrix, or in the case of static or steady-state analysis, the fibers may be assumed to have spring connections, thermal resistance, and/or frictional sliding between the fibers and the composite matrix. The primary objective of this user's manual is to provide an overview of all BEST-CMS capabilities, along with detailed descriptions of the input data requirements. In the next chapter, a brief review of the theoretical background is presented for each analysis category. Then, chapter three discusses the key aspects of the numerical implementation, while chapter four provides a tutorial for the beginning BEST-CMS user. The heart of the manual, however, is in chapter five, where a complete description of all data input items is provided. Within this chapter, the individual entries are grouped on a functional basis for a more coherent presentation. Chapter six includes sample problems and should be of considerable assistance to the novice. Chapter seven includes capsules of a number of fiber-composite analysis problems that have been solved using BEST-CMS. This chapter is primarily descriptive in nature and is intended merely to illustrate the level of analysis that is possible within the present BEST-CMS system. Chapter eight contains a detail description of the BEST-CMS Neutral File which is helpful in writing an interface between BEST-CMS and any graphic post-processor program. Finally, all pertinent references are listed in chapter nine.
New Fast Beam Conditions Monitoring (BCM1F) system for CMS
NASA Astrophysics Data System (ADS)
Zagozdzinska, A. A.; Bell, A. J.; Dabrowski, A. E.; Hempel, M.; Henschel, H. M.; Karacheban, O.; Przyborowski, D.; Leonard, J. L.; Penno, M.; Pozniak, K. T.; Miraglia, M.; Lange, W.; Lohmann, W.; Ryjov, V.; Lokhovitskiy, A.; Stickland, D.; Walsh, R.
2016-01-01
The CMS Beam Radiation Instrumentation and Luminosity (BRIL) project is composed of several systems providing the experiment protection from adverse beam conditions while also measuring the online luminosity and beam background. Although the readout bandwidth of the Fast Beam Conditions Monitoring system (BCM1F—one of the faster monitoring systems of the CMS BRIL), was sufficient for the initial LHC conditions, the foreseen enhancement of the beams parameters after the LHC Long Shutdown-1 (LS1) imposed the upgrade of the system. This paper presents the new BCM1F, which is designed to provide real-time fast diagnosis of beam conditions and instantaneous luminosity with readout able to resolve the 25 ns bunch structure.
The drift velocity monitoring system of the CMS barrel muon chambers
NASA Astrophysics Data System (ADS)
Altenhöfer, Georg; Hebbeker, Thomas; Heidemann, Carsten; Reithler, Hans; Sonnenschein, Lars; Teyssier, Daniel
2018-04-01
The drift velocity is a key parameter of drift chambers. Its value depends on several parameters: electric field, pressure, temperature, gas mixture, and contamination, for example, by ambient air. A dedicated Velocity Drift Chamber (VDC) with 1-L volume has been built at the III. Phys. Institute A, RWTH Aachen, in order to monitor the drift velocity of all CMS barrel muon Drift Tube chambers. A system of six VDCs was installed at CMS and has been running since January 2011. We present the VDC monitoring system, its principle of operation, and measurements performed.
1989-04-20
International Business Machines Corporation) IBM Development System for the Ada Language, VN11/CMS Ada Compiler, Version 2.1.1, Wright-Patterson AFB, IBM 3083...890420W1.10073 International Business Machines Corporation IBM Development System for the Ada Language VM/CMS Ada Compiler Version 2.1.1 IBM 3083... International Business Machines Corporation and reviewed by the validation team. The compiler was tested using all default option settings except for the
1989-04-20
International business Machines Corporati,:i IBM Development System for the Ada Language, CMS/MVS Ada Cross Compiler, Version 2.1.1, Wright-Patterson AFB, IBM...VALIDATION SUMMARY REPORT: Certificate Number: 890420W1.10075 International Business Machines Corporation IBM Development System for the Ada Language CMS...command scripts provided by International Business Machines Corporation and reviewed by the validation team. The compiler was tested using all default
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scholey, J; White, B; Qi, S
2014-06-01
Purpose: To improve the quality of mega-voltage orthogonal scout images (MV topograms) for a fast and low-dose alternative technique for patient localization on the TomoTherapy HiART system. Methods: Digitally reconstructed radiographs (DRR) of anthropomorphic head and pelvis phantoms were synthesized from kVCT under TomoTherapy geometry (kV-DRR). Lateral (LAT) and anterior-posterior (AP) aligned topograms were acquired with couch speeds of 1cm/s, 2cm/s, and 3cm/s. The phantoms were rigidly translated in all spatial directions with known offsets in increments of 5mm, 10mm, and 15mm to simulate daily positioning errors. The contrast of the MV topograms was automatically adjusted based on the imagemore » intensity characteristics. A low-pass fast Fourier transform filter removed high-frequency noise and a Weiner filter reduced stochastic noise caused by scattered radiation to the detector array. An intensity-based image registration algorithm was used to register the MV topograms to a corresponding kV-DRR by minimizing the mean square error between corresponding pixel intensities. The registration accuracy was assessed by comparing the normalized cross correlation coefficients (NCC) between the registered topograms and the kV-DRR. The applied phantom offsets were determined by registering the MV topograms with the kV-DRR and recovering the spatial translation of the MV topograms. Results: The automatic registration technique provided millimeter accuracy and was robust for the deformed MV topograms for three tested couch speeds. The lowest average NCC for all AP and LAT MV topograms was 0.96 for the head phantom and 0.93 for the pelvis phantom. The offsets were recovered to within 1.6mm and 6.5mm for the processed and the original MV topograms respectively. Conclusion: Automatic registration of the processed MV topograms to a corresponding kV-DRR recovered simulated daily positioning errors that were accurate to the order of a millimeter. These results suggest the clinical use of MV topograms as a promising alternative to MVCT patient alignment.« less
77 FR 3477 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-24
... collection for the proper performance of the agency's functions; (2) the accuracy of the estimated burden; (3... submitted to CMS through the 372 web-based form. The report is used by CMS to compare actual data in the... provided is compared to that in the Medicaid Statistical Information System (CMS-R-284, OCN 0938-0345...
Better Off with or without Your CMS? 5 Kinds of Assessment That Can Really Help.
ERIC Educational Resources Information Center
Ehrmann, Stephen C.; Gilbert, Steven W.
2003-01-01
Presents five areas to consider to help establish the value and improve the effectiveness of a course management system (CMS). Highlights include faculty use to improve teaching effectiveness; changes in support strategies to improve the value of a CMS; increasing enrollment or retention; controlling costs; and identifying barriers to desired…
A Planning and Assessment Model for Developing Effective CMS Support
ERIC Educational Resources Information Center
Johnson, Douglas F.
2004-01-01
At the University of Florida, in Spring 2003, more than 32,000 individuals enrolled in courses using the centrally-supported Course Management System (CMS). Because less than 1 full time equivalent (FTE) was allocated to support the CMS, this created problems for both users and support providers. In the face of rapid growth, support resources for…
Reddemann, Antje; Horn, Renate
2018-01-01
Cytoplasmic male sterility (CMS) systems represent ideal mutants to study the role of mitochondria in pollen development. In sunflower, CMS PET2 also has the potential to become an alternative CMS source for commercial sunflower hybrid breeding. CMS PET2 originates from an interspecific cross of H. petiolaris and H. annuus as CMS PET1, but results in a different CMS mechanism. Southern analyses revealed differences for atp6, atp9 and cob between CMS PET2, CMS PET1 and the male-fertile line HA89. A second identical copy of atp6 was present on an additional CMS PET2-specific fragment. In addition, the atp9 gene was duplicated. However, this duplication was followed by an insertion of 271 bp of unknown origin in the 5′ coding region of the atp9 gene in CMS PET2, which led to the creation of two unique open reading frames orf288 and orf231. The first 53 bp of orf288 are identical to the 5′ end of atp9. Orf231 consists apart from the first 3 bp, being part of the 271-bp-insertion, of the last 228 bp of atp9. These CMS PET2-specific orfs are co-transcribed. All 11 editing sites of the atp9 gene present in orf231 are fully edited. The anther-specific reduction of the co-transcript in fertility-restored hybrids supports the involvement in male-sterility based on CMS PET2. PMID:29534485
How many pixels does it take to make a good 4"×6" print? Pixel count wars revisited
NASA Astrophysics Data System (ADS)
Kriss, Michael A.
2011-01-01
In the early 1980's the future of conventional silver-halide photographic systems was of great concern due to the potential introduction of electronic imaging systems then typified by the Sony Mavica analog electronic camera. The focus was on the quality of film-based systems as expressed in the number of equivalent number pixels and bits-per-pixel, and how many pixels would be required to create an equivalent quality image from a digital camera. It was found that 35-mm frames, for ISO 100 color negative film, contained equivalent pixels of 12 microns for a total of 18 million pixels per frame (6 million pixels per layer) with about 6 bits of information per pixel; the introduction of new emulsion technology, tabular AgX grains, increased the value to 8 bit per pixel. Higher ISO speed films had larger equivalent pixels, fewer pixels per frame, but retained the 8 bits per pixel. Further work found that a high quality 3.5" x 5.25" print could be obtained from a three layer system containing 1300 x 1950 pixels per layer or about 7.6 million pixels in all. In short, it became clear that when a digital camera contained about 6 million pixels (in a single layer using a color filter array and appropriate image processing) that digital systems would challenge and replace conventional film-based system for the consumer market. By 2005 this became the reality. Since 2005 there has been a "pixel war" raging amongst digital camera makers. The question arises about just how many pixels are required and are all pixels equal? This paper will provide a practical look at how many pixels are needed for a good print based on the form factor of the sensor (sensor size) and the effective optical modulation transfer function (optical spread function) of the camera lens. Is it better to have 16 million, 5.7-micron pixels or 6 million 7.8-micron pixels? How does intrinsic (no electronic boost) ISO speed and exposure latitude vary with pixel size? A systematic review of these issues will be provided within the context of image quality and ISO speed models developed over the last 15 years.
Buniatian, A A; Sablin, I N; Flerov, E V; Mierbekov, E M; Broĭtman, O G; Shevchenko, V V; Shitikov, I I
1995-01-01
Creation of computer monitoring systems (CMS) for operating rooms is one of the most important spheres of personal computer employment in anesthesiology. The authors developed a PC RS/AT-based CMS and effectively used it for more than 2 years. This system permits comprehensive monitoring in cardiosurgical operations by real time processing the values of arterial and central venous pressure, pressure in the pulmonary artery, bioelectrical activity of the brain, and two temperature values. Use of this CMS helped appreciably improve patients' safety during surgery. The possibility to assess brain function by computer monitoring the EEF simultaneously with central hemodynamics and body temperature permit the anesthesiologist to objectively assess the depth of anesthesia and to diagnose cerebral hypoxia. Automated anesthesiological chart issued by the CMS after surgery reliably reflects the patient's status and the measures taken by the anesthesiologist.
Content management systems and E-commerce: a comparative case study
NASA Astrophysics Data System (ADS)
Al Rasheed, Amal A.; El-Masri, Samir D.
2011-12-01
The need for CMS's to create and edit e-commerce websites has increased with the growing importance of e-commerce. In this paper, the various features essential for e-commerce CMS's are explored. The aim of the paper was to find the best CMS solution for e-commerce which includes the best of both CMS and store management. Accordingly, we conducted a study on three popular open source CMS's for e-commerce: VirtueMart from Joomla!, Ubercart from Drupal, and Magento. We took into account features like hosting and installation, performance, support/community, content management, add on modules and functional features. We concluded with improvements that could be made in order to alleviate problems.
Kang, Lei; Li, Pengfei; Wang, Aifan; Ge, Xianhong; Li, Zaiyun
2017-01-01
A novel cytoplasmic male sterility (CMS) in Brassica napus (inap CMS) was selected from the somatic hybrid with Isatis indigotica (Chinese woad) by recurrent backcrossing. The male sterility was caused by the conversion of tetradynamous stamens into carpelloid structures with stigmatoid tissues at their tips and ovule-like tissues in the margins, and the two shorter stamens into filaments without anthers. The feminized development of the stamens resulted in the complete lack of pollen grains, which was stable in different years and environments. The pistils of inap CMS displayed normal morphology and good seed-set after pollinated by B. napus. Histological sections showed that the developmental alteration of the stamens initiated at the stage of stamen primordium differentiation. AFLP analysis of the nuclear genomic composition with 23 pairs of selective primers detected no woad DNA bands in inap CMS. Twenty out of 25 mitochondrial genes originated from I. indigotica, except for cox2-2 which was the recombinant between cox2 from woad and cox2-2 from rapeseed. The novel cox2-2 was transcribed in flower buds of inap CMS weakly and comparatively with the fertile B. napus addition line Me harboring one particular woad chromosome. The restorers of other autoplasmic and alloplasmic CMS systems in rapeseed failed to restore the fertility of inap CMS and the screening of B. napus wide resources found no fertility restoration variety, showing its distinct origin and the related mechanism of sterility. The reasons for the mitochondrial rearrangements and the breeding of the restorer for the novel CMS system were discussed. PMID:28428799
Lohan, S B; Icken, N; Teutloff, C; Saeidpour, S; Bittl, R; Lademann, J; Fleige, E; Haag, R; Haag, S F; Meinke, M C
2016-03-30
Dendritic core-multi shell (CMS) particles are polymer based systems consisting of a dendritic polar polyglycerol polymer core surrounded by a two-layer shell of nonpolar C18 alkyl chains and hydrophilic polyethylene glycol. Belonging to nanotransport systems (NTS) they allow the transport and storage of molecules with different chemical characters. Their amphipihilic character CMS-NTS permits good solubility in aqueous and organic solutions. We showed by multifrequency electron paramagnetic resonance (EPR) spectroscopy that spin-labeled 5-doxyl stearic acid (5DSA) can be loaded into the CMS-NTS. Furthermore, the release of 5DSA from the carrier into the stratum corneum of porcine skin was monitored ex vivo by EPR spectroscopy. Additionally, the penetration of the CMS-NTS into the skin was analyzed by fluorescence microscopy using indocarbocyanine (ICC) covalently bound to the nanocarrier. Thereby, no transport into the viable skin was observed, whereas the CMS-NTS had penetrated into the hair follicles down to a depth of 340 μm ± 82 μm. Thus, it could be shown that the combined application of fluorescence microscopy and multi-frequency EPR spectroscopy can be an efficient tool for investigating the loading of spin labeled drugs to nanocarrier systems, drug release and penetration into the skin as well as the localization of the NTS in the skin. Copyright © 2016 Elsevier B.V. All rights reserved.
Coastal Modeling System: Mathematical Formulations and Numerical Methods
2014-03-01
sediment transport , and morphology change. The CMS was designed and developed for coastal inlets and navigation applications, including channel...numerical methods of hydrodynamic, salinity and sediment transport , and morphology change model CMS-Flow. The CMS- Flow uses the Finite Volume...and the influence of coastal structures. The implicit hydrodynamic model is coupled to a nonequilibrium transport model of multiple-sized total
The network of photodetectors and diode lasers of the CMS Link alignment system
NASA Astrophysics Data System (ADS)
Arce, P.; Barcala, J. M.; Calvo, E.; Ferrando, A.; Josa, M. I.; Molinero, A.; Navarrete, J.; Oller, J. C.; Brochero, J.; Calderón, A.; Fernández, M. G.; Gómez, G.; González-Sánchez, F. J.; Martínez-Rivero, C.; Matorras, F.; Rodrigo, T.; Ruiz-Árbol, P.; Scodellaro, L.; Sobrón, M.; Vila, I.; Virto, A. L.; Fernández, J.; Raics, P.; Szabó, Zs.; Trócsnyi, Z.; Ujvári, B.; Zilizi, Gy.; Béni, N.; Christian, G.; Imrek, J.; Molnar, J.; Novak, D.; Pálinkás, J.; Székely, G.; Szillási, Z.; Bencze, G. L.; Vestergombi, G.; Benettoni, M.; Gasparini, F.; Montecassiano, F.; Rampazzo, M.; Zago, M.; Benvenuti, A.; Reithler, H.; Jiang, C.
2018-07-01
The central feature of the CMS Link alignment system is a network of Amorphous Silicon Position Detectors distributed throughout the muon spectrometer that are connected by multiple laser lines. The data collected during the years from 2008 to 2015 is presented confirming an outstanding performance of the photo sensors during more than seven years of operation. Details of the photo sensor readout of the laser signals are presented. The mechanical motions of the CMS detector are monitored using these photosensors and good agreement with distance sensors is obtained.
Oxytocin and cardioprotection in diabetes and obesity.
Jankowski, Marek; Broderick, Tom L; Gutkowska, Jolanta
2016-06-07
Oxytocin (OT) emerges as a drug for the treatment of diabetes and obesity. The entire OT system is synthesized in the rat and human heart. The direct myocardial infusion with OT into an ischemic or failing heart has the potential to elicit a variety of cardioprotective effects. OT treatment attenuates cardiomyocyte (CMs) death induced by ischemia-reperfusion by activating pro-survival pathways within injured CMs in vivo and in isolated cells. OT treatment reduces cardiac apoptosis, fibrosis, and hypertrophy. The OT/OT receptor (OTR) system is downregulated in the db/db mouse model of type 2 diabetes which develops genetic diabetic cardiomyopathy (DC) similar to human disease. We have shown that chronic OT treatment prevents the development of DC in the db/db mouse. In addition, OT stimulates glucose uptake in both cardiac stem cells and CMs, and increases cell resistance to diabetic conditions. OT may help replace lost CMs by stimulating the in situ differentiation of cardiac stem cells into functional mature CMs. Lastly, adult stem cells amenable for transplantation such as MSCs could be preconditioned with OT ex vivo and implanted into the injured heart to aid in tissue regeneration through direct differentiation, secretion of protective and cardiomyogenic factors and/or their fusion with injured CMs.
CMS endcap RPC performance analysis
NASA Astrophysics Data System (ADS)
Teng, H.; CMS Collaboration
2014-08-01
The Resistive Plate Chamber (RPC) detector system in LHC-CMS experiment is designed for the trigger purpose. The endcap RPC system has been successfully operated since the commissioning period (2008) to the end of RUN1 (2013). We have developed an analysis tool for endcap RPC performance and validated the efficiency calculation algorithm, focusing on the first endcap station which was assembled and tested by the Peking University group. We cross checked the results obtained with those extracted with alternative methods and we found good agreement in terms of performance parameters [1]. The results showed that the CMS-RPC endcap system fulfilled the performance expected in the Technical Design Report [2].
Zhao, Qinfu; Geng, Hongjian; Wang, Ying; Gao, Yikun; Huang, Jiahao; Wang, Yan; Zhang, Jinghai; Wang, Siling
2014-11-26
A redox-responsive delivery system based on colloidal mesoporous silica (CMS) has been developed, in which 6-mercaptopurine (6-MP) was conjugated to vehicles by cleavable disulfide bonds. The oligosaccharide of hyaluronic acid (oHA) was modified on the surface of CMS by disulfide bonds as a targeting ligand and was able to increase the stability and biocompatibility of CMS under physiological conditions. In vitro release studies indicated that the cumulative release of 6-MP was less than 3% in the absence of glutathione (GSH), and reached nearly 80% within 2 h in the presence of 3 mM GSH. Confocal microscopy and fluorescence-activated cell sorter (FACS) methods were used to evaluate the cellular uptake performance of fluorescein isothiocyanate (FITC) labeled CMS, with and without oHA modification. The CMS-SS-oHA exhibited a higher cellular uptake performance via CD44 receptor-mediated endocytosis in HCT-116 (CD44 receptor-positive) cells than in NIH-3T3 (CD44 receptor-negative) cells. 6-MP loaded CMS-SS-oHA exhibited greater cytotoxicity against HCT-116 cells than NIH-3T3 cells due to the enhanced cell uptake behavior of CMS-SS-oHA. This study provides a novel strategy to covalently link bioactive drug and targeting ligand to the interiors and exteriors of mesoporous silica to construct a stimulus-responsive targeted drug delivery system.
42 CFR 403.300 - Basis and purpose.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PROVISIONS SPECIAL PROGRAMS AND PROJECTS Recognition of State Reimbursement Control Systems § 403.300 Basis... control system must meet in order to be approved by CMS; (2) A description of CMS's review and evaluation...
How the center for Medicare and Medicaid innovation should test accountable care organizations.
Shortell, Stephen M; Casalino, Lawrence P; Fisher, Elliott S
2010-07-01
The Patient Protection and Affordable Care Act establishes a national voluntary program for accountable care organizations (ACOs) by January 2012 under the auspices of the Centers for Medicare and Medicaid Services (CMS). The act also creates a Center for Medicare and Medicaid Innovation in the CMS. We propose that the CMS allow flexibility and tiers in ACOs based on their specific circumstances, such as the degree to which they are or are not fully integrated systems. Further, we propose that the CMS assume responsibility for ACO provisions and develop an ordered system for learning how to create and sustain ACOs. Key steps would include setting specific performance goals, developing skills and tools that facilitate change, establishing measurement and accountability mechanisms, and supporting leadership development.
Identifying Measures of Student Behavior from Interaction with a Course Management System
ERIC Educational Resources Information Center
Nickles, George M., III
2006-01-01
The purpose of this work is to identify process measures of student interaction with a course management system (CMS). Logs maintained by Web servers capture aggregate user interactions with a Website. When combined with a login system and context from the course recorded in the CMS, more detailed measures of individual student interaction can be…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-10
... System AGENCY: Centers for Medicare & Medicaid Services (CMS), HHS. ACTION: Notice of Single Source Award... care system through a single source award. The Indian Health Service (IHS), Tribes and Tribal... adoption and impact of these new authorities on the Indian health care system. Amount of the Award The...
Meyer, Etienne H; Lehmann, Caroline; Boivin, Stéphane; Brings, Lea; De Cauwer, Isabelle; Bock, Ralph; Kühn, Kristina; Touzet, Pascal
2018-02-23
While mitochondrial mutants of the respiratory machinery are rare and often lethal, cytoplasmic male sterility (CMS), a mitochondrially inherited trait that results in pollen abortion, is frequently encountered in wild populations. It generates a breeding system called gynodioecy. In Beta vulgaris ssp. maritima , a gynodioecious species, we found CMS-G to be widespread across the distribution range of the species. Despite the sequencing of the mitochondrial genome of CMS-G, the mitochondrial sterilizing factor causing CMS-G is still unknown. By characterizing biochemically CMS-G, we found that the expression of several mitochondrial proteins is altered in CMS-G plants. In particular, Cox1, a core subunit of the cytochrome c oxidase (complex IV), is larger but can still assemble into complex IV. However, the CMS-G-specific complex IV was only detected as a stabilized dimer. We did not observe any alteration of the affinity of complex IV for cytochrome c ; however, in CMS-G, complex IV capacity is reduced. Our results show that CMS-G is maintained in many natural populations despite being associated with an atypical complex IV. We suggest that the modified complex IV could incur the associated cost predicted by theoretical models to maintain gynodioecy in wild populations. © 2018 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.
Liu, Longjian; Núñez, Ana E
2010-07-01
The authors aimed to examine the prevalence of cardiometabolic syndrome (CMS) and its association with education, smoking, diet, physical activity, and social support among white, black, and Hispanic adults using data from the 2007 Pennsylvania Behavior Risk Factor Surveillance System (BRFSS) survey, the largest population-based survey in the state. The authors examined associations between CMS and associated factors cross-sectionally using univariate and multivariate methods. The study included a representative sample of 12,629 noninstitutionalized Pennsylvanians aged > or =18. Components of CMS included obesity, hypercholesterolemia, angina (as a surrogate for decreased high-density lipoprotein), prehypertension or hypertension, and prediabetes or diabetes. CMS was identified as the presence of > or =3 CMS components. The results show that the prevalence of CMS was 20.48% in blacks, followed by Hispanics (19.14%) and whites (12.26%), (P<.01). Multivariate logistic regression analyses indicated that physical inactivity, lower educational levels, smoking, daily consumption of vegetables and/or fruits <3 servings, and lack of social support were significantly associated with the odds of having CMS. In conclusion, black and Hispanic adults have a significantly higher prevalence of CMS than whites. The significant association between CMS and risk factors provides new insights in the direction of health promotion to prevent and control CMS in those who are at high risk.
A gLite FTS based solution for managing user output in CMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cinquilli, M.; Riahi, H.; Spiga, D.
2012-01-01
The CMS distributed data analysis workflow assumes that jobs run in a different location from where their results are finally stored. Typically the user output must be transferred across the network from one site to another, possibly on a different continent or over links not necessarily validated for high bandwidth/high reliability transfer. This step is named stage-out and in CMS was originally implemented as a synchronous step of the analysis job execution. However, our experience showed the weakness of this approach both in terms of low total job execution efficiency and failure rates, wasting precious CPU resources. The nature ofmore » analysis data makes it inappropriate to use PhEDEx, the core data placement system for CMS. As part of the new generation of CMS Workload Management tools, the Asynchronous Stage-Out system (AsyncStageOut) has been developed to enable third party copy of the user output. The AsyncStageOut component manages glite FTS transfers of data from the temporary store at the site where the job ran to the final location of the data on behalf of that data owner. The tool uses python daemons, built using the WMCore framework, and CouchDB, to manage the queue of work and FTS transfers. CouchDB also provides the platform for a dedicated operations monitoring system. In this paper, we present the motivations of the asynchronous stage-out system. We give an insight into the design and the implementation of key features, describing how it is coupled with the CMS workload management system. Finally, we show the results and the commissioning experience.« less
Viel, Alexis; Henri, Jérôme; Bouchène, Salim; Laroche, Julian; Rolland, Jean-Guy; Manceau, Jacqueline; Laurentie, Michel; Couet, William; Grégoire, Nicolas
2018-03-12
The objective was the development of a whole-body physiologically-based pharmacokinetic (WB-PBPK) model for colistin, and its prodrug colistimethate sodium (CMS), in pigs to explore their tissue distribution, especially in kidneys. Plasma and tissue concentrations of CMS and colistin were measured after systemic administrations of different dosing regimens of CMS in pigs. The WB-PBPK model was developed based on these data according to a non-linear mixed effect approach and using NONMEM software. A detailed sub-model was implemented for kidneys to handle the complex disposition of CMS and colistin within this organ. The WB-PBPK model well captured the kinetic profiles of CMS and colistin in plasma. In kidneys, an accumulation and slow elimination of colistin were observed and well described by the model. Kidneys seemed to have a major role in the elimination processes, through tubular secretion of CMS and intracellular degradation of colistin. Lastly, to illustrate the usefulness of the PBPK model, an estimation of the withdrawal periods after veterinary use of CMS in pigs was made. The WB-PBPK model gives an insight into the renal distribution and elimination of CMS and colistin in pigs; it may be further developed to explore the colistin induced-nephrotoxicity in humans.
78 FR 63211 - Privacy Act of 1974; Report of an Altered CMS System of Records Notice
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-23
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services Privacy Act of... Services (CMS), Department of Health and Human Services (HHS). ACTION: Altered System of Records Notice...), Veterans Health Administration (Champ VA), Children's Health Insurance Program (CHIP), Department of...
23 CFR 970.214 - Federal lands congestion management system (CMS).
Code of Federal Regulations, 2011 CFR
2011-04-01
... experiencing congestion, the NPS shall develop a separate CMS to cover those facilities. Approaches may include... congestion management strategies; (v) Determine methods to monitor and evaluate the performance of the multi... means the level at which transportation system performance is no longer acceptable due to traffic...
23 CFR 973.214 - Indian lands congestion management system (CMS).
Code of Federal Regulations, 2010 CFR
2010-04-01
... HIGHWAYS MANAGEMENT SYSTEMS PERTAINING TO THE BUREAU OF INDIAN AFFAIRS AND THE INDIAN RESERVATION ROADS... performance is no longer acceptable due to traffic interference. The BIA and the FHWA, in consultation with the tribes, shall develop criteria to determine when a CMS is to be implemented for a specific...
23 CFR 970.214 - Federal lands congestion management system (CMS).
Code of Federal Regulations, 2010 CFR
2010-04-01
... experiencing congestion, the NPS shall develop a separate CMS to cover those facilities. Approaches may include... congestion management strategies; (v) Determine methods to monitor and evaluate the performance of the multi... means the level at which transportation system performance is no longer acceptable due to traffic...
23 CFR 973.214 - Indian lands congestion management system (CMS).
Code of Federal Regulations, 2011 CFR
2011-04-01
... HIGHWAYS MANAGEMENT SYSTEMS PERTAINING TO THE BUREAU OF INDIAN AFFAIRS AND THE INDIAN RESERVATION ROADS... performance is no longer acceptable due to traffic interference. The BIA and the FHWA, in consultation with the tribes, shall develop criteria to determine when a CMS is to be implemented for a specific...
Dynamically re-configurable CMOS imagers for an active vision system
NASA Technical Reports Server (NTRS)
Yang, Guang (Inventor); Pain, Bedabrata (Inventor)
2005-01-01
A vision system is disclosed. The system includes a pixel array, at least one multi-resolution window operation circuit, and a pixel averaging circuit. The pixel array has an array of pixels configured to receive light signals from an image having at least one tracking target. The multi-resolution window operation circuits are configured to process the image. Each of the multi-resolution window operation circuits processes each tracking target within a particular multi-resolution window. The pixel averaging circuit is configured to sample and average pixels within the particular multi-resolution window.
NASA Technical Reports Server (NTRS)
Banerjee, P. K.; Henry, D. P.; Hopkins, D. A.; Goldberg, R. K.
1997-01-01
BEST-CMS (Boundary Element Solution Technology - Composite Modeling System) is an advanced engineering system for the micro-analysis of fiber composite structures. BEST-CMS is based upon the boundary element program BEST3D which was developed for NASA by Pratt and Whitney Aircraft and the State University of New York at Buffalo under contract NAS3-23697. BEST-CMS presently has the capabilities for elastostatic analysis, steady-state and transient heat transfer analysis, steady-state and transient concurrent thermoelastic analysis and elastoplastic and creep analysis. The fibers are assumed to be perfectly bonded to the composite matrix, or in the case of static or steady-state analysis, the fibers may be assumed to have spring connections, thermal resistance, and/or frictional sliding between the fibers and the composite matrix. The primary objective of this User's Manual is to provide an overview of all BEST-CMS capabilities, along with detailed descriptions of the input data requirements. A brief review of the theoretical background is presented for each analysis category. Then, Chapter 3 discusses the key aspects of the numerical implementation, while Chapter 4 provides a tutorial for the beginning BEST-CMS user. The heart of the manual, however, is in Chapter 5, where a complete description of all data input items is provided. Within this chapter, the individual entries are grouped on a functional basis for a more coherent presentation. Chapter 6 includes sample problems and should be of considerable assistance to the novice. Chapter 7 includes capsules of a number of fiber-composite analysis problems that have been solved using BEST-CMS. This chapter is primarily descriptive in nature and is intended merely to illustrate the level of analysis that is possible within the present BEST-CMS system. Chapter 8 contains a detailed description of the BEST-CMS Neutral File which is helpful in writing an interface between BEST- CMS and any graphic post-processor program. Finally, all pertinent references are listed in Chapter 9.
A simulation framework for the CMS Track Trigger electronics
NASA Astrophysics Data System (ADS)
Amstutz, C.; Magazzù, G.; Weber, M.; Palla, F.
2015-03-01
A simulation framework has been developed to test and characterize algorithms, architectures and hardware implementations of the vastly complex CMS Track Trigger for the high luminosity upgrade of the CMS experiment at the Large Hadron Collider in Geneva. High-level SystemC models of all system components have been developed to simulate a portion of the track trigger. The simulation of the system components together with input data from physics simulations allows evaluating figures of merit, like delays or bandwidths, under realistic conditions. The use of SystemC for high-level modelling allows co-simulation with models developed in Hardware Description Languages, e.g. VHDL or Verilog. Therefore, the simulation framework can also be used as a test bench for digital modules developed for the final system.
Recent Highlights of Metabolomics in Chinese Medicine Syndrome Research
Zhang, Ai-hua; Sun, Hui; Qiu, Shi; Wang, Xi-jun
2013-01-01
Chinese medicine syndrome (CMS, “ZHENG” in Chinese) is an understanding of the regularity of disease occurrence and development as well as a certain stage of a comprehensive response of patients with body condition. However, because of the complexity of CMS and the limitation of present investigation method, the research for deciphering the scientific basis and systematic features of CMS is difficult to go further. Metabolomics enables mapping of early biochemical changes in disease and hence provides an opportunity to develop predictive biomarkers. Moreover, its method and design resemble those of traditional Chinese medicine (TCM) which focuses on human disease via the integrity of close relationship between body and syndromes. In the systemic context, metabolomics has a convergence with TCM syndrome; therefore it could provide useful tools for exploring essence of CMS disease, facilitating personalized TCM, and will help to in-depth understand CMS. The integration of the metabolomics and CMS aspects will give promise to bridge the gap between Chinese and Western medicine and help catch the traditional features of CMS. In this paper, particular attention will be paid to the past successes in applications of robust metabolomic approaches to contribute to low-molecular-weight metabolites (biomarkers) discovery in CMS research and development. PMID:24302964
The profitability of automatic milking on Dutch dairy farms.
Bijl, R; Kooistra, S R; Hogeveen, H
2007-01-01
Several studies have reported on the profitability of automatic milking based on different simulation models, but a data-based study using actual farm data has been lacking. The objective of this study was to analyze the profitability of dairy farms having an automatic milking system (AMS) compared with farms using a conventional milking system (CMS) based on real accounting data. In total, 62 farms (31 using an AMS and 31 using a CMS) were analyzed for the year 2003 in a case control study. Differences between the years 2002 and 2003 also were analyzed by comparing a subgroup of 16 farms with an AMS and 16 farms with a CMS. Matching was based on the time of investment in a milking system (same year), the total milk production per year, and intensity of land use (kg/ha). Results from 2003 showed that the farms with an AMS used, on average, 29% less labor than farms with a CMS. In contrast, farms using a CMS grew faster (37,132 kg of milk quota and 5 dairy cows) than farms with an AMS (-3,756 kg milk quota and 0.5 dairy cows) between 2002 and 2003. Dairy farmers with a CMS had larger (euro7,899) revenues than those with an AMS. However, no difference in the margin on dairy production was detected, partly because of numerically greater (euro6,822) variable costs on CMS farms. Dairy farms were compared financially based on the amount of money that was available for rent, depreciation, interest, labor, and profit (RDILP). The CMS farms had more money (euro15,566) available for RDILP than the AMS farms. This difference was caused by larger fixed costs (excluding labor) for the AMS farms, larger contractor costs (euro6,422), and larger costs for gas, water, and electricity (euro1,549). Differences in costs for contractors and for gas, water, and electricity were statistically significant. When expressed per full-time employee, AMS farms had greater revenues, margins, and gross margins per full-time employee than did CMS farms. This resulted in a substantially greater (but not statistically significant) RDILP per full-time employee (euro12,953) for AMS farms compared with CMS farms. Depreciation and interest costs for automatic milking were not available but were calculated based on several assumptions. Assuming larger purchase costs and a shorter depreciation time for AMS than for CMS, costs for depreciation and interest were larger for AMS farms than for CMS farms. Larger fixed costs should be compensated for by the amount of labor that has become available after introducing the milking robot. Therefore, farm managers should decide whether the extra time acquired by automatic milking balances against the extra costs associated with an AMS.
Castillo, Almudena; Rodríguez-Suárez, Cristina; Martín, Azahara C.; Pistón, Fernando
2015-01-01
Exploiting hybrid wheat heterosis has been long pursued to increase crop yield, stability and uniformity. Cytoplasmic male sterility (CMS) systems based in the nuclear-cytoplasmic incompatible interactions are a classic way for hybrid seed production, but to date, no definitive system is available in wheat. The msH1 CMS system results from the incompatibility between the nuclear genome of wheat and the cytoplasmic genome of the wild barley Hordeum chilense. Fertility restoration of the CMS phenotype was first associated with the disomic addition of the short arm of chromosome 6H from H. chilense. In further studies it was observed that chromosome arm 1HchS was also implicated, and the combination of genes in both chromosome arms restored fertility more efficiently. In this work we aim to dissect the effect of each chromosome in fertility restoration when combined in different genomic backgrounds and under different environmental conditions. We propose a model to explain how restoration behaves in the msH1 system and generate valuable information necessary to develop an efficient system for hybrid wheat production. PMID:26192191
Castillo, Almudena; Rodríguez-Suárez, Cristina; Martín, Azahara C; Pistón, Fernando
2015-01-01
Exploiting hybrid wheat heterosis has been long pursued to increase crop yield, stability and uniformity. Cytoplasmic male sterility (CMS) systems based in the nuclear-cytoplasmic incompatible interactions are a classic way for hybrid seed production, but to date, no definitive system is available in wheat. The msH1 CMS system results from the incompatibility between the nuclear genome of wheat and the cytoplasmic genome of the wild barley Hordeum chilense. Fertility restoration of the CMS phenotype was first associated with the disomic addition of the short arm of chromosome 6H from H. chilense. In further studies it was observed that chromosome arm 1HchS was also implicated, and the combination of genes in both chromosome arms restored fertility more efficiently. In this work we aim to dissect the effect of each chromosome in fertility restoration when combined in different genomic backgrounds and under different environmental conditions. We propose a model to explain how restoration behaves in the msH1 system and generate valuable information necessary to develop an efficient system for hybrid wheat production.
CMS Data Processing Workflows during an Extended Cosmic Ray Run
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2009-11-01
The CMS Collaboration conducted a month-long data taking exercise, the Cosmic Run At Four Tesla, during October-November 2008, with the goal of commissioning the experiment for extended operation. With all installed detector systems participating, CMS recorded 270 million cosmic ray events with the solenoid at a magnetic field strength of 3.8 T. This paper describes the data flow from the detector through the various online and offline computing systems, as well as the workflows used for recording the data, for aligning and calibrating the detector, and for analysis of the data.
Monitoring techniques and alarm procedures for CMS services and sites in WLCG
DOE Office of Scientific and Technical Information (OSTI.GOV)
Molina-Perez, J.; Bonacorsi, D.; Gutsche, O.
2012-01-01
The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS, the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operatingmore » worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.« less
Effective HTCondor-based monitoring system for CMS
NASA Astrophysics Data System (ADS)
Balcas, J.; Bockelman, B. P.; Da Silva, J. M.; Hernandez, J.; Khan, F. A.; Letts, J.; Mascheroni, M.; Mason, D. A.; Perez-Calero Yzquierdo, A.; Vlimant, J.-R.; pre="for the"> CMS Consortium, 2017-10-01 The CMS experiment at the LHC relies on HTCondor and glideinWMS as its primary batch and pilot-based Grid provisioning systems, respectively. Given the scale of the global queue in CMS, the operators found it increasingly difficult to monitor the pool to find problems and fix them. The operators had to rely on several different web pages, with several different levels of information, and sift tirelessly through log files in order to monitor the pool completely. Therefore, coming up with a suitable monitoring system was one of the crucial items before the beginning of the LHC Run 2 in order to ensure early detection of issues and to give a good overview of the whole pool. Our new monitoring page utilizes the HTCondor ClassAd information to provide a complete picture of the whole submission infrastructure in CMS. The monitoring page includes useful information from HTCondor schedulers, central managers, the glideinWMS frontend, and factories. It also incorporates information about users and tasks making it easy for operators to provide support and debug issues.
Gong, Xue-Lian; Gao, Ting-Ting; Zhao, Li-Jun; Zhu, Hai; Xia, Zhen-Na; Lu, Wen; Lu, Guo-Cai
2014-08-01
CMS-1, mainly composed of imperatorin as its active compound, is a partially purified fraction of a Chinese herbal medicine, Semen Cnidium monnieri. CMS-1 has the potential to be further developed as a new treatment for hypertension. Thus, we studied its toxicity in both Sprague-Dawley rats and beagle dogs. Rats (0-900mg/kg/day) and dogs (0-450mg/kg/day) received CMS-1 orally for 30 consecutive days, followed by a 15-day recovery period. The major target organs of CMS-1 toxicity are the GI (inappetence), liver (hepatocellular necrosis, enzyme elevation), thymus (atrophy), cardiovascular (hypotension), changes in ECG T and P waveforms, elevation of nitrous oxide levels and hematological (RBC parameters disturbances) systems. Most treatment-induced adverse effects were reversible or showed a progressive recovery upon discontinuation of the treatment. The No Observed Adverse Effect Level (NOAEL) was 100mg/kg/day for rats and 50mg/kg/day for dogs. This non-clinical study suggests that clinical monitoring of CMS-1 in patients should focus on the gastrointestinal system, blood tests for liver functions, electrolytes, and blood homeostasis, cardiovascular functions, and immune functions. Copyright © 2014 Elsevier Inc. All rights reserved.
Dendritic Core-Multishell Nanocarriers in Murine Models of Healthy and Atopic Skin.
Radbruch, Moritz; Pischon, Hannah; Ostrowski, Anja; Volz, Pierre; Brodwolf, Robert; Neumann, Falko; Unbehauen, Michael; Kleuser, Burkhard; Haag, Rainer; Ma, Nan; Alexiev, Ulrike; Mundhenk, Lars; Gruber, Achim D
2017-12-01
Dendritic hPG-amid-C18-mPEG core-multishell nanocarriers (CMS) represent a novel class of unimolecular micelles that hold great potential as drug transporters, e.g., to facilitate topical therapy in skin diseases. Atopic dermatitis is among the most common inflammatory skin disorders with complex barrier alterations which may affect the efficacy of topical treatment.Here, we tested the penetration behavior and identified target structures of unloaded CMS after topical administration in healthy mice and in mice with oxazolone-induced atopic dermatitis. We further examined whole body distribution and possible systemic side effects after simulating high dosage dermal penetration by subcutaneous injection.Following topical administration, CMS accumulated in the stratum corneum without penetration into deeper viable epidermal layers. The same was observed in atopic dermatitis mice, indicating that barrier alterations in atopic dermatitis had no influence on the penetration of CMS. Following subcutaneous injection, CMS were deposited in the regional lymph nodes as well as in liver, spleen, lung, and kidney. However, in vitro toxicity tests, clinical data, and morphometry-assisted histopathological analyses yielded no evidence of any toxic or otherwise adverse local or systemic effects of CMS, nor did they affect the severity or course of atopic dermatitis.Taken together, CMS accumulate in the stratum corneum in both healthy and inflammatory skin and appear to be highly biocompatible in the mouse even under conditions of atopic dermatitis and thus could potentially serve to create a depot for anti-inflammatory drugs in the skin.
Zhang, Yiping; Chi, Chengdeng; Huang, Xiaoyi; Zou, Qin; Li, Xiaoxi; Chen, Ling
2017-09-01
Anionic carboxymethyl starch (CMS) and cationic quaternary ammonium starch (QAS), were used to fabricate nanocapsules through electrostatic layer by layer (LbL) alternate deposition onto colloidal BSA particles. An ideal starch-based colloidal nanocapsule was achieved by adjusting the degree of substitution (DS) and weight average molecular molar mass (M w ) of CMS. The nanocapsules fabricated by CMS with lower DS or M w possessed more compact and stable core-shell structure, which favoured the BSA delivery from the upper gastrointestinal tract (GIT) to the colon. In particular, CMS/QAS nanocapsules constructed by CMS with lower DS and M w showed better colon-specific delivery and release performance in simulated GIT fluid after 7days' storage in different kinds of beverage (33.04%-46.35% in upper GIT, 52.70%-64.97% in colon, respectively). These findings demonstrated that CMS/QAS nanocapsules constructed by CMS with lower DS and M w can be further exploited as a potential oral delivery system for protein to colon. Copyright © 2017 Elsevier Ltd. All rights reserved.
From Static to Dynamic: Choosing and Implementing a Web-Based CMS
ERIC Educational Resources Information Center
Kneale, Ruth
2008-01-01
Working as systems librarian for the Advanced Technology Solar Telescope (ATST), a project for the National Solar Observatory (NSO) based in Tucson, Arizona, a large part of the author's responsibilities involve running the web site. She began looking into content management systems (CMSs), specifically ones for website control. A CMS is generally…
Specifics of Course Management System Benefits for New University Faculty
ERIC Educational Resources Information Center
Porter, Gavin
2011-01-01
A comparison of courses that do or do not utilize a Course Management System (CMS) was undertaken from the standpoint of a new faculty member. Seven distinct advantages were found with CMS implementation including initial tutorial group set-ups, email communication, sharing of student generated products, sharing of instructor-generated products,…
Hönzke, Stefan; Gerecke, Christian; Elpelt, Anja; Zhang, Nan; Unbehauen, Michael; Kral, Vivian; Fleige, Emanuel; Paulus, Florian; Haag, Rainer; Schäfer-Korting, Monika; Kleuser, Burkhard; Hedtrich, Sarah
2016-11-28
Drug loaded dendritic core-multishell (CMS) nanocarriers are of especial interest for the treatment of skin diseases, owing to their striking dermal delivery efficiencies following topical applications. CMS nanocarriers are composed of a polyglycerol core, connected by amide-bonds to an inner alkyl shell and an outer methoxy poly(ethylene glycol) shell. Since topically applied nanocarriers are subjected to biodegradation, the application of conventional amide-based CMS nanocarriers (10-A-18-350) has been limited by the potential production of toxic polyglycerol amines. To circumvent this issue, three tailored ester-based CMS nanocarriers (10-E-12-350, 10-E-15-350, 10-E-18-350) of varying inner alkyl chain length were synthesized and comprehensively characterized in terms of particle size, drug loading, biodegradation and dermal drug delivery efficiency. Dexamethasone (DXM), a potent drug widely used for the treatment of inflammatory skin diseases, was chosen as a therapeutically relevant test compound for the present study. Ester- and amide-based CMS nanocarriers delivered DXM more efficiently into human skin than a commercially available DXM cream. Subsequent in vitro and in vivo toxicity studies identified CMS (10-E-15-350) as the most biocompatible carrier system. The anti-inflammatory potency of DXM-loaded CMS (10-E-15-350) nanocarriers was assessed in TNFα supplemented skin models, where a significant reduction of the pro-inflammatory cytokine IL-8 was seen, with markedly greater efficacy than commercial DXM cream. In summary, we report the rational design and characterization of tailored, biodegradable, ester-based CMS nanocarriers, and their subsequent stepwise screening for biocompatibility, dermal delivery efficiency and therapeutic efficacy in a top-down approach yielding the best carrier system for topical applications. Copyright © 2016 Elsevier B.V. All rights reserved.
Dual-RiverSonde measurements of two-dimensional river flow patterns
Teague, C.C.; Barrick, D.E.; Lilleboe, P.M.; Cheng, R.T.; Stumpner, P.; Burau, J.R.
2008-01-01
Two-dimensional river flow patterns have been measured using a pair of RiverSondes in two experiments in the Sacramento-San Joaquin River Delta system of central California during April and October 2007. An experiment was conducted at Walnut Grove, California in order to explore the use of dual RiverSondes to measure flow patterns at a location which is important in the study of juvenile fish migration. The data available during the first experiment were limited by low wind, so a second experiment was conducted at Threemile Slough where wind conditions and surface turbulence historically have resulted in abundant data. Both experiments included ADCP near-surface velocity measurements from either manned or unmanned boats. Both experiments showed good comparisons between the RiverSonde and ADCP measurements. The flow conditions at both locations are dominated by tidal effects, with partial flow reversal at Walnut Grove and complete flow reversal at Threemile Slough. Both systems showed complex flow patterns during the flow reversals. Quantitative comparisons between the RiverSondes and an ADCP on a manned boat at Walnut Grove showed mean differences of 4.5 cm/s in the u (eastward) and 7.6 cm/s in the v (northward) components, and RMS differences of 14.7 cm/s in the u component and 21.0 cm/s in the v component. Quantitative comparisons between the RiverSondes and ADCPs on autonomous survey vessels at Threemile Slough showed mean differences of 0.007 cm/s in the u component and 0.5 cm/s in the v component, and RMS differences of 7.9 cm/s in the u component and 13.5 cm/s in the v component after obvious outliers were removed. ?? 2008 IEEE.
Using the GlideinWMS System as a Common Resource Provisioning Layer in CMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balcas, J.; Belforte, S.; Bockelman, B.
2015-12-23
CMS will require access to more than 125k processor cores for the beginning of Run 2 in 2015 to carry out its ambitious physics program with more and higher complexity events. During Run1 these resources were predominantly provided by a mix of grid sites and local batch resources. During the long shut down cloud infrastructures, diverse opportunistic resources and HPC supercomputing centers were made available to CMS, which further complicated the operations of the submission infrastructure. In this presentation we will discuss the CMS effort to adopt and deploy the glideinWMS system as a common resource provisioning layer to grid,more » cloud, local batch, and opportunistic resources and sites. We will address the challenges associated with integrating the various types of resources, the efficiency gains and simplifications associated with using a common resource provisioning layer, and discuss the solutions found. We will finish with an outlook of future plans for how CMS is moving forward on resource provisioning for more heterogenous architectures and services.« less
Villafuerte, Francisco C; Corante, Noemí; Anza-Ramírez, Cecilia; Figueroa-Mujíca, Rómulo; Vizcardo-Galindo, Gustavo; Mercado, Andy; Macarlupú, José Luis; León-Velarde, Fabiola
2016-07-01
Excessive erythrocytosis (EE) is the main sign of Chronic Mountain Sickness (CMS), a highly prevalent syndrome in Andean highlanders. Low pulse O2 saturation (SpO2) during sleep and serum androgens have been suggested to contribute to EE in CMS patients. However, whether these factors have a significant impact on the erythropoietin (Epo) system leading to EE is still unclear. We have recently shown that morning soluble Epo receptor (sEpoR), an endogenous Epo antagonist, is decreased in CMS patients suggesting increased Epo availability (increased Epo/sEpoR). The present study aimed to characterize the nocturnal concentration profile of sEpoR and Epo and their relationship with SpO2, Hct, and serum testosterone in healthy highlanders (HH) and CMS patients. Epo and sEpoR concentrations were evaluated every 4 h (6 PM to 6 AM) and nighttime SpO2 was continuously monitored (10 PM to 6 AM) in 39 male participants (CMS, n = 23; HH, n = 16) aged 21-65 yr from Cerro de Pasco, Peru (4,340 m). CMS patients showed higher serum Epo concentrations throughout the night and lower sEpoR from 10 PM to 6 AM. Consequently, Epo/sEpoR was significantly higher in the CMS group at every time point. Mean sleep-time SpO2 was lower in CMS patients compared with HH, while the percentage of sleep time spent with SpO2 < 80% was higher. Multiple-regression analysis showed mean sleep-time SpO2 and Epo/sEpoR as significant predictors of hematocrit corrected for potential confounders (age, body mass index, and testosterone). Testosterone levels were associated neither with Hct nor with erythropoietic factors. In conclusion, our results show sustained erythropoietic stimulus driven by the Epo system in CMS patients, further enhanced by a continuous exposure to accentuated nocturnal hypoxemia. Copyright © 2016 the American Physiological Society.
Corante, Noemí; Anza-Ramírez, Cecilia; Figueroa-Mujíca, Rómulo; Vizcardo-Galindo, Gustavo; Mercado, Andy; Macarlupú, José Luis; León-Velarde, Fabiola
2016-01-01
Excessive erythrocytosis (EE) is the main sign of Chronic Mountain Sickness (CMS), a highly prevalent syndrome in Andean highlanders. Low pulse O2 saturation (SpO2) during sleep and serum androgens have been suggested to contribute to EE in CMS patients. However, whether these factors have a significant impact on the erythropoietin (Epo) system leading to EE is still unclear. We have recently shown that morning soluble Epo receptor (sEpoR), an endogenous Epo antagonist, is decreased in CMS patients suggesting increased Epo availability (increased Epo/sEpoR). The present study aimed to characterize the nocturnal concentration profile of sEpoR and Epo and their relationship with SpO2, Hct, and serum testosterone in healthy highlanders (HH) and CMS patients. Epo and sEpoR concentrations were evaluated every 4 h (6 PM to 6 AM) and nighttime SpO2 was continuously monitored (10 PM to 6 AM) in 39 male participants (CMS, n = 23; HH, n = 16) aged 21-65 yr from Cerro de Pasco, Peru (4,340 m). CMS patients showed higher serum Epo concentrations throughout the night and lower sEpoR from 10 PM to 6 AM. Consequently, Epo/sEpoR was significantly higher in the CMS group at every time point. Mean sleep-time SpO2 was lower in CMS patients compared with HH, while the percentage of sleep time spent with SpO2 < 80% was higher. Multiple-regression analysis showed mean sleep-time SpO2 and Epo/sEpoR as significant predictors of hematocrit corrected for potential confounders (age, body mass index, and testosterone). Testosterone levels were associated neither with Hct nor with erythropoietic factors. In conclusion, our results show sustained erythropoietic stimulus driven by the Epo system in CMS patients, further enhanced by a continuous exposure to accentuated nocturnal hypoxemia. PMID:27125843
Course Management Systems: Traveling Beyond Powerpoint Slides Online
NASA Astrophysics Data System (ADS)
Gauthier, A. J.; Impey, C. D.
2004-12-01
Course management systems (CMS) like WebCT, Blackboard, Astronomica, etc., have reached and surpassed their tipping point in higher education. They are no longer a technology-trendy item to use in a course, but rather an expected supplement to undergraduate courses. There is a well known disconnect between the student population of ''digital natives'' (1) and higher education instructors, the ''digital immigrants'' (1). What expectations and technology skills do the new generations of undergraduates have? How can instructors easily meet their students' needs? What needs do instructors have and what resources are available to meet those needs? In the past, instructors would create their own HTML web pages to post class materials like PowerPoint slides, homework, and announcements. How does an instructor-created web resource differ from a secure university run CMS? How can you make your university or college's CMS system into a productive learning tool and not just a repository for class materials and grades? How can the astronomy instructor benefit from integrating a CMS into their course? What are common student attitudes regarding CMS usage in a course? How are instructors using CMSs in innovative ways? Where on your campus can you get free help designing and implementing a CMS resource for your students? This presentation aims to answer these questions. Extensive literature reviews, formal surveys, case study reports, and educational research from the instructional technology community inform our astronomy teaching community of the answers. Highlights from innovative systems and uses of CMSs in undergraduate Astro 101 classrooms will be presented. Resources and further references will be made available as handouts. (1) M. Prensky. ''Digital Natives, Digital Immigrants,'' On The Horizon, Vol.9, 2001.
Waves at Navigation Structures
2015-10-30
upgrades the Coastal Modeling System (CMS) wave models CMS-Wave, a phase- averaged spectral wave model, and BOUSS-2D, a Boussinesq type nonlinear wave...developing WaveNet and TideNet, two Web-based tool systems for wind and wave data access and processing, which provide critical data for USACE project...practical applications, resulting in optimization of navigation system to improve safety, reliability and operations with innovative infrastructures
Method and system for non-linear motion estimation
NASA Technical Reports Server (NTRS)
Lu, Ligang (Inventor)
2011-01-01
A method and system for extrapolating and interpolating a visual signal including determining a first motion vector between a first pixel position in a first image to a second pixel position in a second image, determining a second motion vector between the second pixel position in the second image and a third pixel position in a third image, determining a third motion vector between one of the first pixel position in the first image and the second pixel position in the second image, and the second pixel position in the second image and the third pixel position in the third image using a non-linear model, determining a position of the fourth pixel in a fourth image based upon the third motion vector.
NASA Technical Reports Server (NTRS)
Liebowitz, Jay
1986-01-01
At NASA Goddard, the role of the command management system (CMS) is to transform general requests for spacecraft opeerations into detailed operational plans to be uplinked to the spacecraft. The CMS is part of the NASA Data System which entails the downlink of science and engineering data from NASA near-earth satellites to the user, and the uplink of command and control data to the spacecraft. Presently, it takes one to three years, with meetings once or twice a week, to determine functional requirements for CMS software design. As an alternative approach to the present technique of developing CMS software functional requirements, an expert system prototype was developed to aid in this function. Specifically, the knowledge base was formulated through interactions with domain experts, and was then linked to an existing expert system application generator called 'Knowledge Engineering System (Version 1.3).' Knowledge base development focused on four major steps: (1) develop the problem-oriented attribute hierachy; (2) determine the knowledge management approach; (3) encode the knowledge base; and (4) validate, test, certify, and evaluate the knowledge base and the expert system prototype as a whole. Backcasting was accomplished for validating and testing the expert system prototype. Knowledge refinement, evaluation, and implementation procedures of the expert system prototype were then transacted.
Kong, Chi-Wing; Geng, Lin; Li, Ronald A
2018-01-01
Considerable interest has been raised to develop human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) as a model for drug discovery and cardiotoxicity screening. High-content electrophysiological analysis of currents generated by transmembrane cell surface ion channels has been pursued to complement such emerging applications. Here we describe practical procedures and considerations for accomplishing successful assays of hPSC-CMs using an automated planar patch-clamp system.
A Non-Equilibrium Sediment Transport Model for Coastal Inlets and Navigation Channels
2011-01-01
exchange of water , sediment, and nutrients between estuaries and the ocean. Because of the multiple interacting forces (waves, wind, tide, river...in parallel using OpenMP. The CMS takes advantage of the Surface- water Modeling System (SMS) interface for grid generation and model setup, as well...as for plotting and post- processing (Zundel, 2000). The circulation model in the CMS (called CMS-Flow) computes the unsteady water level and
Synthesis and Characterization of Hyaluronic Acid Modified Colloidal Mesoporous Silica Nanoparticles
NASA Astrophysics Data System (ADS)
Zhang, Wenbiao; Wang, Yu; Li, Zhen; Wang, Wanxia; Sun, Honghao; Liu, Mingxing
2017-12-01
The colloidal mesoporous silica nanoparticles functionalized with hyaluronic acid (CMS-HA) were successfully synthesized by grafting hyaluronic acid onto the external surface of the amino-functionalized mesoporous silica nanoparticles (CMS-NH2). Moreover, the paticle properties of CMS-HA were characterized by fourier transform infrared spectroscopy (FT-IR), dynamic light scattering (DLS) and transmission electron microscopy (TEM). The nanomaterials were negatively charged and had a relatively uniform spherical morphology with about 100 nm in diameter, which could make it more compatible with blood. So the results suggested that the CMS-HA might be a critical nanomaterial for applying in target drug delivery system.
SiteDB: Marshalling people and resources available to CMS
NASA Astrophysics Data System (ADS)
Metson, S.; Bonacorsi, D.; Dias Ferreira, M.; Egeland, R.
2010-04-01
In a collaboration the size of CMS (approx. 3000 users, and almost 100 computing centres of varying size) communication and accurate information about the sites it has access to is vital in co-ordinating the multitude of computing tasks required for smooth running. SiteDB is a tool developed by CMS to track sites available to the collaboration, the allocation to CMS of resources available at those sites and the associations between CMS members and the sites (as either a manager/operator of the site or a member of a group associated to the site). It is used to track the roles a person has for an associated site or group. SiteDB eases the coordination load for the operations teams by providing a consistent interface to manage communication with the people working at a site, by identifying who is responsible for a given task or service at a site and by offering a uniform interface to information on CMS contacts and sites. SiteDB provides api's and reports for other CMS tools to use to access the information it contains, for instance enabling CRAB to use "user friendly" names when black/white listing CE's, providing role based authentication and authorisation for other web based services and populating various troubleshooting squads in external ticketing systems in use daily by CMS Computing operations.
Nicole, Sophie; Azuma, Yoshiteru; Bauché, Stéphanie; Eymard, Bruno; Lochmüller, Hanns; Slater, Clarke
2017-01-01
Congenital myasthenic syndromes (CMS) form a heterogeneous group of rare diseases characterized by fatigable muscle weakness. They are genetically-inherited and caused by defective synaptic transmission at the cholinergic neuromuscular junction (NMJ). The number of genes known to cause CMS when mutated is currently 30, and the relationship between fatigable muscle weakness and defective functions is quite well-understood for many of them. However, some of the most recent discoveries in individuals with CMS challenge our knowledge of the NMJ, where the basis of the pathology has mostly been investigated in animal models. Frontier forms between CMS and congenital myopathy, which have been genetically and clinically identified, underline the poorly understood interplay between the synaptic and extrasynaptic molecules in the neuromuscular system. In addition, precise electrophysiological and histopathological investigations of individuals with CMS suggest an important role of NMJ plasticity in the response to CMS pathogenesis. While efficient drug-based treatments are already available to improve neuromuscular transmission for most forms of CMS, others, as well as neurological and muscular comorbidities, remain resistant. Taken together, the available pathological data point to physiological issues which remain to be understood in order to achieve precision medicine with efficient therapeutics for all individuals suffering from CMS. PMID:29125502
Dreiling, Michelle; Schiffner, Rene; Bischoff, Sabine; Rupprecht, Sven; Kroegel, Nasim; Schubert, Harald; Witte, Otto W; Schwab, Matthias; Rakers, Florian
2018-01-01
Acute stress-induced reduction of uterine blood flow (UBF) is an indirect mechanism of maternal-fetal stress transfer during late gestation. Effects of chronic psychosocial maternal stress (CMS) during early gestation, as may be experienced by many working women, on this stress signaling mechanism are unclear. We hypothesized that CMS in sheep during early gestation augments later acute stress-induced decreases of UBF, and aggravates the fetal hormonal, cardiovascular, and metabolic stress responses during later development. Six pregnant ewes underwent repeated isolation stress (CMS) between 30 and 100 days of gestation (dGA, term: 150 dGA) and seven pregnant ewes served as controls. At 110 dGA, ewes were chronically instrumented and underwent acute isolation stress. The acute stress decreased UBF by 19% in both the CMS and control groups (p < .05), but this was prolonged in CMS versus control ewes (74 vs. 30 min, p < .05). CMS increased fetal circulating baseline and stress-induced cortisol and norepinephrine concentrations indicating a hyperactive hypothalamus-pituitary-adrenal (HPA)-axis and sympathetic-adrenal-medullary system. Increased fetal norepinephrine is endogenous as maternal catecholamines do not cross the placenta. Cortisol in the control but not in the CMS fetuses was correlated with maternal cortisol blood concentrations; these findings indicate: (1) no increased maternal-fetal cortisol transfer with CMS, (2) cortisol production in CMS fetuses when the HPA-axis is normally inactive, due to early maturation of the fetal HPA-axis. CMS fetuses were better oxygenated, without shift towards acidosis compared to the controls, potentially reflecting adaptation to repeated stress. Hence, CMS enhances maternal-fetal stress transfer by prolonged reduction in UBF and increased fetal HPA responsiveness.
Brennan, Niall; Oelschlaeger, Allison; Cox, Christine; Tavenner, Marilyn
2014-07-01
As the largest single payer for health care in the United States, the Centers for Medicare and Medicaid Services (CMS) generates enormous amounts of data. Historically, CMS has faced technological challenges in storing, analyzing, and disseminating this information because of its volume and privacy concerns. However, rapid progress in the fields of data architecture, storage, and analysis--the big-data revolution--over the past several years has given CMS the capabilities to use data in new and innovative ways. We describe the different types of CMS data being used both internally and externally, and we highlight a selection of innovative ways in which big-data techniques are being used to generate actionable information from CMS data more effectively. These include the use of real-time analytics for program monitoring and detecting fraud and abuse and the increased provision of data to providers, researchers, beneficiaries, and other stakeholders. Project HOPE—The People-to-People Health Foundation, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffrey A Appel
BTeV is a new Fermilab beauty and charm experiment designed to operate in the CZero region of the Tevatron collider. Critical to the success of BTeV is its pixel detector. The unique features of this pixel detector include its proximity to the beam, its operation with a beam crossing time of 132 ns, and the need for the detector information to be read out quickly enough to be used for the lowest level trigger. This talk presents an overview of the pixel detector design, giving the motivations for the technical choices made. The status of the current R&D on detectormore » components is also reviewed. Additional Pixel 2002 talks on the BTeV pixel detector are given by Dave Christian[1], Mayling Wong[2], and Sergio Zimmermann[3]. Table 1 gives a selection of pixel detector parameters for the ALICE, ATLAS, BTeV, and CMS experiments. Comparing the progression of this table, which I have been updating for the last several years, has shown a convergence of specifications. Nevertheless, significant differences endure. The BTeV data-driven readout, horizontal and vertical position resolution better than 9 {micro}m with the {+-} 300 mr forward acceptance, and positioning in vacuum and as close as 6 mm from the circulating beams remain unique. These features are driven by the physics goals of the BTeV experiment. Table 2 demonstrates that the vertex trigger performance made possible by these features is requisite for a very large fraction of the B meson decay physics which is so central to the motivation for BTeV. For most of the physics quantities of interest listed in the table, the vertex trigger is essential. The performance of the BTeV pixel detector may be summarized by looking at particular physics examples; e.g., the B{sub s} meson decay B{sub s} {yields} D{sub s}{sup -} K{sup +}. For that decay, studies using GEANT3 simulations provide quantitative measures of performance. For example, the separation between the B{sub s} decay point and the primary proton-antiproton interaction can be measured with an rms uncertainty of 138 {micro}m. This, with the uncertainty in the decay vertex position, leads to an uncertainty of the B{sub s} proper decay time of 46 fs. Even if the parameter x{sub s} equals 25 (where the current lower limit on x{sub s} is about 15), the corresponding relevant proper time is 400 fs. So, the detector resolution is more than adequate to make an excellent measurement of this parameter.« less
ERIC Educational Resources Information Center
Koszalka, Tiffany A.; Ganesan, Radha
2004-01-01
Course developers can be distracted from applying sound instructional design principles by the amount of flexibility offered through online course development resources (Kidney & Puckett, "Quarterly Review of Distance Education," 4 (2003), 203-212). Distance education course management systems (CMS) provide multiple features that can be easily…
Potential Use of Course Management Systems in Higher Education Institutions in Jordan
ERIC Educational Resources Information Center
Al-Shboul, Muhannad
2011-01-01
Given the increased adoption of the CMS (course management systems) as an instructional tool, it is important to address the potential use of this technology in Jordanian higher education institutions. This study investigates the potential to use CMS tools in instruction in the academic institutions in Jordan. This study does not seek to evaluate…
ERIC Educational Resources Information Center
Li, Yi; Wang, Qiu; Campbell, John
2015-01-01
This study focused on learning equity in colleges and universities where teaching and learning depends heavily on computer technologies. The study used the Structural Equation Modeling (SEM) to investigate gender and racial/ethnic heterogeneity in the use of a computer based course management system (CMS). Two latent variables (CMS usage and…
Waves at Navigation Structures
2014-10-27
upgrades the Coastal Modeling System’s (CMS) wave model CMS-Wave, a phase-averaged spectral wave model, and BOUSS-2D, a Boussinesq -type nonlinear wave...nearshore wave processes in practical applications. These capabilities facilitate optimization of innovative infrastructure for navigation systems to...navigation systems . The advanced models develop probabilistic engineering design estimates for rehabilitation of coastal structures to evaluate the
A secure steganography for privacy protection in healthcare system.
Liu, Jing; Tang, Guangming; Sun, Yifeng
2013-04-01
Private data in healthcare system require confidentiality protection while transmitting. Steganography is the art of concealing data into a cover media for conveying messages confidentially. In this paper, we propose a steganographic method which can provide private data in medical system with very secure protection. In our method, a cover image is first mapped into a 1D pixels sequence by Hilbert filling curve and then divided into non-overlapping embedding units with three consecutive pixels. We use adaptive pixel pair match (APPM) method to embed digits in the pixel value differences (PVD) of the three pixels and the base of embedded digits is dependent on the differences among the three pixels. By solving an optimization problem, minimal distortion of the pixel ternaries caused by data embedding can be obtained. The experimental results show our method is more suitable to privacy protection of healthcare system than prior steganographic works.
Comprehensive monitoring for heterogeneous geographically distributed storage
Ratnikova, Natalia; Karavakis, E.; Lammel, S.; ...
2015-12-23
Storage capacity at CMS Tier-1 and Tier-2 sites reached over 100 Petabytes in 2014, and will be substantially increased during Run 2 data taking. The allocation of storage for the individual users analysis data, which is not accounted as a centrally managed storage space, will be increased to up to 40%. For comprehensive tracking and monitoring of the storage utilization across all participating sites, CMS developed a space monitoring system, which provides a central view of the geographically dispersed heterogeneous storage systems. The first prototype was deployed at pilot sites in summer 2014, and has been substantially reworked since then.more » In this study, we discuss the functionality and our experience of system deployment and operation on the full CMS scale.« less
NASA Astrophysics Data System (ADS)
Zabolotny, W. M.; Byszuk, A.
2016-03-01
The CMS experiment Level-1 trigger system is undergoing an upgrade. In the barrel-endcap transition region, it is necessary to merge data from 3 types of muon detectors—RPC, DT and CSC. The Overlap Muon Track Finder (OMTF) uses the novel approach to concentrate and process those data in a uniform manner to identify muons and their transversal momentum. The paper presents the algorithm and FPGA firmware implementation of the OMTF and its data transmission system in CMS. It is foreseen that the OMTF will be subject to significant changes resulting from optimization which will be done with the aid of physics simulations. Therefore, a special, high-level, parameterized HDL implementation is necessary.
Boisson, Matthieu; Jacobs, Matthieu; Grégoire, Nicolas; Gobin, Patrice; Marchand, Sandrine; Couet, William; Mimoz, Olivier
2014-12-01
Colistin is an old antibiotic that has recently gained a considerable renewal of interest for the treatment of pulmonary infections due to multidrug-resistant Gram-negative bacteria. Nebulization seems to be a promising form of administration, but colistin is administered as an inactive prodrug, colistin methanesulfonate (CMS); however, differences between the intrapulmonary concentrations of the active moiety as a function of the route of administration in critically ill patients have not been precisely documented. In this study, CMS and colistin concentrations were measured on two separate occasions within the plasma and epithelial lining fluid (ELF) of critically ill patients (n = 12) who had received 2 million international units (MIU) of CMS by aerosol delivery and then intravenous administration. The pharmacokinetic analysis was conducted using a population approach and completed by pharmacokinetic-pharmacodynamic (PK-PD) modeling and simulations. The ELF colistin concentrations varied considerably (9.53 to 1,137 mg/liter), but they were much higher than those in plasma (0.15 to 0.73 mg/liter) after aerosol delivery but not after intravenous administration of CMS. Following CMS aerosol delivery, typically, 9% of the CMS dose reached the ELF, and only 1.4% was presystemically converted into colistin. PK-PD analysis concluded that there was much higher antimicrobial efficacy after CMS aerosol delivery than after intravenous administration. These new data seem to support the use of aerosol delivery of CMS for the treatment of pulmonary infections in critical care patients. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Boisson, Matthieu; Jacobs, Matthieu; Grégoire, Nicolas; Gobin, Patrice; Marchand, Sandrine; Mimoz, Olivier
2014-01-01
Colistin is an old antibiotic that has recently gained a considerable renewal of interest for the treatment of pulmonary infections due to multidrug-resistant Gram-negative bacteria. Nebulization seems to be a promising form of administration, but colistin is administered as an inactive prodrug, colistin methanesulfonate (CMS); however, differences between the intrapulmonary concentrations of the active moiety as a function of the route of administration in critically ill patients have not been precisely documented. In this study, CMS and colistin concentrations were measured on two separate occasions within the plasma and epithelial lining fluid (ELF) of critically ill patients (n = 12) who had received 2 million international units (MIU) of CMS by aerosol delivery and then intravenous administration. The pharmacokinetic analysis was conducted using a population approach and completed by pharmacokinetic-pharmacodynamic (PK-PD) modeling and simulations. The ELF colistin concentrations varied considerably (9.53 to 1,137 mg/liter), but they were much higher than those in plasma (0.15 to 0.73 mg/liter) after aerosol delivery but not after intravenous administration of CMS. Following CMS aerosol delivery, typically, 9% of the CMS dose reached the ELF, and only 1.4% was presystemically converted into colistin. PK-PD analysis concluded that there was much higher antimicrobial efficacy after CMS aerosol delivery than after intravenous administration. These new data seem to support the use of aerosol delivery of CMS for the treatment of pulmonary infections in critical care patients. PMID:25267660
CMS results in the Combined Computing Readiness Challenge CCRC'08
NASA Astrophysics Data System (ADS)
Bonacorsi, D.; Bauerdick, L.; CMS Collaboration
2009-12-01
During February and May 2008, CMS participated to the Combined Computing Readiness Challenge (CCRC'08) together with all other LHC experiments. The purpose of this worldwide exercise was to check the readiness of the Computing infrastructure for LHC data taking. Another set of major CMS tests called Computing, Software and Analysis challenge (CSA'08) - as well as CMS cosmic runs - were also running at the same time: CCRC augmented the load on computing with additional tests to validate and stress-test all CMS computing workflows at full data taking scale, also extending this to the global WLCG community. CMS exercised most aspects of the CMS computing model, with very comprehensive tests. During May 2008, CMS moved more than 3.6 Petabytes among more than 300 links in the complex Grid topology. CMS demonstrated that is able to safely move data out of CERN to the Tier-1 sites, sustaining more than 600 MB/s as a daily average for more than seven days in a row, with enough headroom and with hourly peaks of up to 1.7 GB/s. CMS ran hundreds of simultaneous jobs at each Tier-1 site, re-reconstructing and skimming hundreds of millions of events. After re-reconstruction the fresh AOD (Analysis Object Data) has to be synchronized between Tier-1 centers: CMS demonstrated that the required inter-Tier-1 transfers are achievable within a few days. CMS also showed that skimmed analysis data sets can be transferred to Tier-2 sites for analysis at sufficient rate, regionally as well as inter-regionally, achieving all goals in about 90% of >200 links. Simultaneously, CMS also ran a large Tier-2 analysis exercise, where realistic analysis jobs were submitted to a large set of Tier-2 sites by a large number of people to produce a chaotic workload across the systems, and with more than 400 analysis users in May. Taken all together, CMS routinely achieved submissions of 100k jobs/day, with peaks up to 200k jobs/day. The achieved results in CCRC'08 - focussing on the distributed workflows - are presented and discussed.
NASA Astrophysics Data System (ADS)
Escobar, V. M.; Sepulveda Carlo, E.; Delgado Arias, S.
2016-12-01
During the past six years, the NASA Carbon Monitoring System (CMS) Applications effort has been engaging with stakeholders in an effort to make the 52 CMS project user friendly and policy relevant. Congressionally directed, the CMS initiative is a NASA endeavor providing carbon data products that help characterize and understand carbon sources and sinks at local and international scales. All data are freely available, and scaled for local, state, regional, national and international-level resource management. To facilitate user feedback during development, as well as understanding for the type of use and application the CMS data products can provide, the Applications project utilizes the NASA Applied Sciences Program nine step Application Readiness Level (ARL) indices. These are used to track and manage the progression and distribution of funded projects. ARLs are an adaptation of NASA's technology readiness levels (TRLs) used for managing technology and risk and reflects the three main tiers of a project: research, development and deployment. The ARLs are scaled from 1 to 9, research and development (ARL1) to operational and/or decision making ready products (ARL9). The ARLS can be broken up into three phases: Phase 1, discovery and feasibility (ARL 1-3); Phase 2, development testing and validation (ARL 4-6); and Phase 3, integration into Partner's systems (ARL 7-9). The ARLs are designed to inform both scientist and end user of the product maturity and application capability. The CMS initiative has products that range across all ARLs, providing societal benefit at multiple scales. Lower ARLs contribute to formal documents such as the IPCC while others at higher levels provide decision support quantifying the value of carbon data for greenhouse gas (GHG) reduction planning. Most CMS products have an ARL 5, (validation of a product in a relevant environment), meaning the CMS carbon science is actively in a state of science-user engagement. For the user community, ARLs are a litmus test for knowing the type of user feedback and advocacy that can be implemented into the product design. For the scientist, ARLS help communicate (1) the maturity of their science to users who would like to use it for decision making and (2) the intended use of the product.
CMOS Active Pixel Sensor Star Tracker with Regional Electronic Shutter
NASA Technical Reports Server (NTRS)
Yadid-Pecht, Orly; Pain, Bedabrata; Staller, Craig; Clark, Christopher; Fossum, Eric
1996-01-01
The guidance system in a spacecraft determines spacecraft attitude by matching an observed star field to a star catalog....An APS(active pixel sensor)-based system can reduce mass and power consumption and radiation effects compared to a CCD(charge-coupled device)-based system...This paper reports an APS (active pixel sensor) with locally variable times, achieved through individual pixel reset (IPR).
Method and System for Temporal Filtering in Video Compression Systems
NASA Technical Reports Server (NTRS)
Lu, Ligang; He, Drake; Jagmohan, Ashish; Sheinin, Vadim
2011-01-01
Three related innovations combine improved non-linear motion estimation, video coding, and video compression. The first system comprises a method in which side information is generated using an adaptive, non-linear motion model. This method enables extrapolating and interpolating a visual signal, including determining the first motion vector between the first pixel position in a first image to a second pixel position in a second image; determining a second motion vector between the second pixel position in the second image and a third pixel position in a third image; determining a third motion vector between the first pixel position in the first image and the second pixel position in the second image, the second pixel position in the second image, and the third pixel position in the third image using a non-linear model; and determining a position of the fourth pixel in a fourth image based upon the third motion vector. For the video compression element, the video encoder has low computational complexity and high compression efficiency. The disclosed system comprises a video encoder and a decoder. The encoder converts the source frame into a space-frequency representation, estimates the conditional statistics of at least one vector of space-frequency coefficients with similar frequencies, and is conditioned on previously encoded data. It estimates an encoding rate based on the conditional statistics and applies a Slepian-Wolf code with the computed encoding rate. The method for decoding includes generating a side-information vector of frequency coefficients based on previously decoded source data and encoder statistics and previous reconstructions of the source frequency vector. It also performs Slepian-Wolf decoding of a source frequency vector based on the generated side-information and the Slepian-Wolf code bits. The video coding element includes receiving a first reference frame having a first pixel value at a first pixel position, a second reference frame having a second pixel value at a second pixel position, and a third reference frame having a third pixel value at a third pixel position. It determines a first motion vector between the first pixel position and the second pixel position, a second motion vector between the second pixel position and the third pixel position, and a fourth pixel value for a fourth frame based upon a linear or nonlinear combination of the first pixel value, the second pixel value, and the third pixel value. A stationary filtering process determines the estimated pixel values. The parameters of the filter may be predetermined constants.
Potential Regional Sediment Management (RSM) Projects in the Haleiwa Region, Oahu, Hawaii
2014-05-01
relic stream channels on wave -induced flow patterns. Wave breaking and energy dissipation over the reefs result in return currents (from nearshore to...long), (c) a stub breakwater (80 ft long), and (d) a wave absorber (140 ft long). The non-federal sponsor for the harbor is the State of Hawaii...Coastal Inlets Research Program (CIRP) Coastal Modeling System (CMS) numerical models CMS- Wave and CMS- Flow (Sanchez et al. 2011) were implemented to
Pharmacokinetics of Chinese medicines: strategies and perspectives.
Yan, Ru; Yang, Ying; Chen, Yijia
2018-01-01
The modernization and internationalization of Chinese medicines (CMs) are hampered by increasing concerns on the safety and the efficacy. Pharmacokinetic (PK) study is indispensable to establish concentration-activity/toxicity relationship and facilitate target identification and new drug discovery from CMs. To cope with tremendous challenges rooted from chemical complexity of CMs, the classic PK strategies have evolved rapidly from PK study focusing on marker/main drug components to PK-PD correlation study adopting metabolomics approaches to characterize associations between disposition of global drug-related components and host metabolic network shifts. However, the majority of PK studies of CMs have adopted the approaches tailored for western medicines and focused on the systemic exposures of drug-related components, most of which were found to be too low to account for the holistic benefits of CMs. With an area under concentration-time curve- or activity-weighted approach, integral PK attempts to understand the PK-PD relevance with the integrated PK profile of multiple co-existing structural analogs (prototyes/metabolites). Cellular PK-PD complements traditional PK-PD when drug targets localize inside the cells, instead of at the surface of cell membrane or extracellular space. Considering the validated clinical benefits of CMs, reverse pharmacology-based reverse PK strategy was proposed to facilitate target identification and new drug discovery. Recently, gut microbiota have demonstrated multifaceted roles in drug efficacy/toxicity. In traditional oral intake, the presystemic interactions of CMs with gut microbiota seem inevitable, which can contribute to the holistic benefits of CMs through biotransforming CMs components, acting as the peripheral target, and regulating host drug disposition. Hence, we propose a global PK-PD approach which includes the presystemic interaction of CMs with gut microbiota and combines omics with physiologically based pharmacokinetic modeling to offer a comprehensive understanding of the PK-PD relationship of CMs. Moreover, validated clinical benefits of CMs and poor translational potential of animal PK data urge more research efforts in human PK study.
Human cardiomyocyte generation from pluripotent stem cells: A state-of-art.
Talkhabi, Mahmood; Aghdami, Nasser; Baharvand, Hossein
2016-01-15
The human heart is considered a non-regenerative organ. Worldwide, cardiovascular diseases continue to be the leading cause of death. Despite advances in cardiac treatment, myocardial repair remains severely limited by the lack of an appropriate source of viable cardiomyocytes (CMs) to replace damaged tissue. Human pluripotent stem cells (hPSCs), embryonic stem cells (ESCs) and induced pluripotent stem cells (iPSCs) can efficiently be differentiated into functional CMs necessary for cell replacement therapy and other potential applications. The number of protocols that derive CMs from hPSCs has increased exponentially over the past decade following observation of the first human beating CMs. A number of highly efficient, chemical based protocols have been developed to generate human CMs (hCMs) in small-scale and large-scale suspension systems. To reduce the heterogeneity of hPSC-derived CMs, the differentiation protocols were modulated to exclusively generate atrial-, ventricular-, and nodal-like CM subtypes. Recently, remarkable advances have been achieved in hCM generation including chemical-based cardiac differentiation, cardiac subtype specification, large-scale suspension culture differentiation, and development of chemically defined culture conditions. These hCMs could be useful particularly in the context of in vitro disease modeling, pharmaceutical screening and in cellular replacement therapies once the safety issues are overcome. Herein we review recent progress in the in vitro generation of CMs and cardiac subtypes from hPSCs and discuss their potential applications and current limitations. Copyright © 2015 Elsevier Inc. All rights reserved.
Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il
2014-01-01
Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected. PMID:25051037
Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il
2014-07-21
Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected.
A design of optical modulation system with pixel-level modulation accuracy
NASA Astrophysics Data System (ADS)
Zheng, Shiwei; Qu, Xinghua; Feng, Wei; Liang, Baoqiu
2018-01-01
Vision measurement has been widely used in the field of dimensional measurement and surface metrology. However, traditional methods of vision measurement have many limits such as low dynamic range and poor reconfigurability. The optical modulation system before image formation has the advantage of high dynamic range, high accuracy and more flexibility, and the modulation accuracy is the key parameter which determines the accuracy and effectiveness of optical modulation system. In this paper, an optical modulation system with pixel level accuracy is designed and built based on multi-points reflective imaging theory and digital micromirror device (DMD). The system consisted of digital micromirror device, CCD camera and lens. Firstly we achieved accurate pixel-to-pixel correspondence between the DMD mirrors and the CCD pixels by moire fringe and an image processing of sampling and interpolation. Then we built three coordinate systems and calculated the mathematic relationship between the coordinate of digital micro-mirror and CCD pixels using a checkerboard pattern. A verification experiment proves that the correspondence error is less than 0.5 pixel. The results show that the modulation accuracy of system meets the requirements of modulation. Furthermore, the high reflecting edge of a metal circular piece can be detected using the system, which proves the effectiveness of the optical modulation system.
Commissioning of the first chambers of the CMS GE1/1 muon station
NASA Astrophysics Data System (ADS)
Ressegotti, Martina; CMS Muon Group
2017-12-01
The upgrades of the LHC planned in the next years will increase the instantaneous luminosity up to 5 × 1034 cm -2 s -1 after Long Shutdown 3, a value about five times higher than the nominal one for which the CMS experiment was designed. The resulting larger rate of interactions will produce a higher pileup environment that will challenge the trigger system of the CMS experiment in its original configuration, in particular in the endcap region. As part of the upgrade program of the CMS muon endcaps, additional muon detectors based on Gas Electron Multiplier (GEM) technology will be installed, in order to be able to sustain a physics program during high-luminosity operation without performance losses. The installation of the GE1/1 station is scheduled for Long Shutdown 2 in 2019-2020 already a demonstrator composed of five superchambers has been installed during the Extended Year-End Technical Stop at the beginning of 2017. Its goal is to test the system’s operational conditions and also to demonstrate the integration of the GE1/1 chambers into the CMS online system. The status of the installation and commissioning of the GE1/1 demonstrator is presented.
Muons in the CMS High Level Trigger System
NASA Astrophysics Data System (ADS)
Verwilligen, Piet; CMS Collaboration
2016-04-01
The trigger systems of LHC detectors play a fundamental role in defining the physics capabilities of the experiments. A reduction of several orders of magnitude in the rate of collected events, with respect to the proton-proton bunch crossing rate generated by the LHC, is mandatory to cope with the limits imposed by the readout and storage system. An accurate and efficient online selection mechanism is thus required to fulfill the task keeping maximal the acceptance to physics signals. The CMS experiment operates using a two-level trigger system. Firstly a Level-1 Trigger (L1T) system, implemented using custom-designed electronics, is designed to reduce the event rate to a limit compatible to the CMS Data Acquisition (DAQ) capabilities. A High Level Trigger System (HLT) follows, aimed at further reducing the rate of collected events finally stored for analysis purposes. The latter consists of a streamlined version of the CMS offline reconstruction software and operates on a computer farm. It runs algorithms optimized to make a trade-off between computational complexity, rate reduction and high selection efficiency. With the computing power available in 2012 the maximum reconstruction time at HLT was about 200 ms per event, at the nominal L1T rate of 100 kHz. An efficient selection of muons at HLT, as well as an accurate measurement of their properties, such as transverse momentum and isolation, is fundamental for the CMS physics programme. The performance of the muon HLT for single and double muon triggers achieved in Run I will be presented. Results from new developments, aimed at improving the performance of the algorithms for the harsher scenarios of collisions per event (pile-up) and luminosity expected for Run II will also be discussed.
Lv, C L; Liu, Q B; Cai, C Y; Huang, J; Zhou, G W; Wang, Y G
2015-01-01
In the transmission electron microscopy, a revised real space (RRS) method has been confirmed to be a more accurate dynamical electron diffraction simulation method for low-energy electron diffraction than the conventional multislice method (CMS). However, the RRS method can be only used to calculate the dynamical electron diffraction of orthogonal crystal system. In this work, the expression of the RRS method for non-orthogonal crystal system is derived. By taking Na2 Ti3 O7 and Si as examples, the correctness of the derived RRS formula for non-orthogonal crystal system is confirmed by testing the coincidence of numerical results of both sides of Schrödinger equation; moreover, the difference between the RRS method and the CMS for non-orthogonal crystal system is compared at the accelerating voltage range from 40 to 10 kV. Our results show that the CMS method is almost the same as the RRS method for the accelerating voltage above 40 kV. However, when the accelerating voltage is further lowered to 20 kV or below, the CMS method introduces significant errors, not only for the higher-order Laue zone diffractions, but also for zero-order Laue zone. These indicate that the RRS method for non-orthogonal crystal system is necessary to be used for more accurate dynamical simulation when the accelerating voltage is low. Furthermore, the reason for the increase of differences between those diffraction patterns calculated by the RRS method and the CMS method with the decrease of the accelerating voltage is discussed. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Theoretical analysis of HVAC duct hanger systems
NASA Technical Reports Server (NTRS)
Miller, R. D.
1987-01-01
Several methods are presented which, together, may be used in the analysis of duct hanger systems over a wide range of frequencies. The finite element method (FEM) and component mode synthesis (CMS) method are used for low- to mid-frequency range computations and have been shown to yield reasonably close results. The statistical energy analysis (SEA) method yields predictions which agree with the CMS results for the 800 to 1000 Hz range provided that a sufficient number of modes participate. The CMS approach has been shown to yield valuable insight into the mid-frequency range of the analysis. It has been demonstrated that it is possible to conduct an analysis of a duct/hanger system in a cost-effective way for a wide frequency range, using several methods which overlap for several frequency bands.
Zhang, Xiaoqian; Cao, Henghua; Bai, Shuyun; Huo, Weibang; Ma, Yue
2017-04-01
The combination of non-human primate animals and their induced pluripotent stem cell derived cardiomyocytes (iPSC-CMs) provides not only transplantation models for cell-based therapy of heart diseases, but also opportunities for heart-related drug research on both cellular and animal levels. However, the subtypes and electrophysiology properties of non-human primate iPSC-CMs hadn't been detailed characterized. In this study, we generated rhesus monkey induced pluripotent stem cells (riPSCs), and efficiently differentiated them into ventricular or atrial cardiomyocytes by modulating retinoic acid (RA) pathways. Our results revealed that the electrophysiological characteristics and response to canonical drugs of riPSC-CMs were similar with those of human pluripotent stem cell derived CMs. Therefore, rhesus monkeys and their iPSC-CMs provide a powerful and practicable system for heart related biomedical research. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Park, Jong Seok; Aziz, Moez Karim; Li, Sensen; Chi, Taiyun; Grijalva, Sandra Ivonne; Sung, Jung Hoon; Cho, Hee Cheol; Wang, Hua
2018-02-01
This paper presents a fully integrated CMOS multimodality joint sensor/stimulator array with 1024 pixels for real-time holistic cellular characterization and drug screening. The proposed system consists of four pixel groups and four parallel signal-conditioning blocks. Every pixel group contains 16 × 16 pixels, and each pixel includes one gold-plated electrode, four photodiodes, and in-pixel circuits, within a pixel footprint. Each pixel supports real-time extracellular potential recording, optical detection, charge-balanced biphasic current stimulation, and cellular impedance measurement for the same cellular sample. The proposed system is fabricated in a standard 130-nm CMOS process. Rat cardiomyocytes are successfully cultured on-chip. Measured high-resolution optical opacity images, extracellular potential recordings, biphasic current stimulations, and cellular impedance images demonstrate the unique advantages of the system for holistic cell characterization and drug screening. Furthermore, this paper demonstrates the use of optical detection on the on-chip cultured cardiomyocytes to real-time track their cyclic beating pattern and beating rate.
Collision models in quantum optics
NASA Astrophysics Data System (ADS)
Ciccarello, Francesco
2017-12-01
Quantum collision models (CMs) provide advantageous case studies for investigating major issues in open quantum systems theory, and especially quantum non-Markovianity. After reviewing their general definition and distinctive features, we illustrate the emergence of a CM in a familiar quantum optics scenario. This task is carried out by highlighting the close connection between the well-known input-output formalism and CMs. Within this quantum optics framework, usual assumptions in the CMs' literature - such as considering a bath of noninteracting yet initially correlated ancillas - have a clear physical origin.
Monitoring the CMS strip tracker readout system
NASA Astrophysics Data System (ADS)
Mersi, S.; Bainbridge, R.; Baulieu, G.; Bel, S.; Cole, J.; Cripps, N.; Delaere, C.; Drouhin, F.; Fulcher, J.; Giassi, A.; Gross, L.; Hahn, K.; Mirabito, L.; Nikolic, M.; Tkaczyk, S.; Wingham, M.
2008-07-01
The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system.
Post-operative paediatric cerebellar mutism syndrome: time to move beyond structural MRI.
Toescu, Sebastian M; Hettige, Samantha; Phipps, Kim; Smith, R J Paul; Haffenden, Verity; Clark, Chris; Hayward, Richard; Mankad, Kshitij; Aquilina, Kristian
2018-06-20
To determine the value of structural magnetic resonance imaging (MRI) in predicting post-operative paediatric cerebellar mutism syndrome (pCMS) in children undergoing surgical treatment for medulloblastoma. Retrospective cohort study design. Electronic/paper case note review of all children with medulloblastoma presenting to Great Ormond Street Hospital between 2003 and 2013. The diagnosis of pCMS was established through a scoring system incorporating mutism, ataxia, behavioural disturbance and cranial nerve deficits. MRI scans performed at three time points were assessed by neuroradiologists blinded to the diagnosis of pCMS. Of 56 children included, 12 (21.4%) developed pCMS as judged by a core symptom of mutism. pCMS was more common in those aged 5 or younger. There was no statistically significant difference in pre-operative distortion or signal change of the dentate or red nuclei or superior cerebellar peduncles (SCPs) between those who did and did not develop pCMS. In both early (median 5 days) and late (median 31 months) post-operative scans, T2-weighted signal change in SCPs was more common in the pCMS group (p = 0.040 and 0.046 respectively). Late scans also showed statistically significant signal change in the dentate nuclei (p = 0.024). The development of pCMS could not be linked to any observable changes on pre-operative structural MRI scans. Post-operative T2-weighted signal change in the SCPs and dentate nuclei underlines the role of cerebellar efferent injury in pCMS. Further research using advanced quantitative MRI sequences is warranted given the inability of conventional pre-surgical MRI to predict pCMS.
47 CFR 10.210 - CMAS participation election procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 10.210 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM... requirements implemented by the Commission; and (2) Commits to support the development and deployment of technology for the “C” interface, the CMS provider Gateway, the CMS provider infrastructure, and mobile...
47 CFR 10.210 - CMAS participation election procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 10.210 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM... requirements implemented by the Commission; and (2) Commits to support the development and deployment of technology for the “C” interface, the CMS provider Gateway, the CMS provider infrastructure, and mobile...
Explore the high-density QCD medium via particle correlations in pPb collisions at CMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Wei, E-mail: wl33@rice.edu
2015-01-15
The observation of a long-range, near-side two-particle correlation (“ridge”) in very high multiplicity proton–proton and proton–lead collisions has opened up new opportunity of studying novel QCD phenomena in small collision systems. In 2013, high luminosity pPb data were collected by the CMS experiment at the LHC. New results of two- and multi-particle correlations in pPb collisions from CMS are presented over a wide event multiplicity and transverse momentum range. A direct comparison of pPb and PbPb systems is provided. Physics implications, especially in the context of color glass condensate and hydrodynamics models are also discussed.
NASA Astrophysics Data System (ADS)
Alpat, Behcet; Ergin, Tulun; Kalemci, Emrah
2016-07-01
The Mini-SPT project is the first, and most important, step towards the ambitious goal of creating a low-cost, compact, radiation hardened and high performance space particle telescope that can be mounted, in the near future, as standard particle detector on any satellite. Mini-SPT will be capable of providing high quality physics data on local space environment. In particular high precision flux measurement and tracking of low energy protons and electrons on different orbits with same instrumentation is of paramount importance for studies as geomagnetically trapped fluxes and space weather dynamics, dark matter search, low energy proton anisotropy and its effects on ICs as well as the solar protons studies. In addition, it will provide real-time "differentiable warnings" about the local space radiation hazard to other electronics systems on board the hosting satellite, including different criticality levels and alarm signals to activate mitigation techniques whenever this is strictly necessary to protect them from temporary/permanent failures. A real-time warning system will help satellite subsystems to save significant amount of power and memory with respect to other conventional techniques where the "mitigation" solutions are required to be active during entire mission life. The Mini-SPT will combine the use of technologies developed in cutting-edge high energy physics experiments (including technology from CMS experiments at CERN) and the development of new charged particle detecting systems for their use for the first time in space. The Mini-SPT essential objective is, by using for the first time in space SIPMs (Silicon Photomultipliers) technology for TOF and energy measurements, the production of high quality data with a good time, position and energy resolutions. The mini-SPT will consists of three main sub-units: a- A tracking and dE/dX measuring sub-detector which will be based on silicon pixel detectors (SPD) coupled to the rad-hard chip ROC-DIG (Read Out Chip-Digital version), developed and bump bonded to high accuracy radiation hardened particle barrel pixel detector in CMS (Compact Magnetic Solenoid) experiment of LHC (Large Hadron Collider) at CERN-Geneva b- The calorimeter (CCAL) system will consist of a scintillating crystal optically coupled to an array of silicon photomultipliers (SIPMs) to read out the photons created in the crystal by impinging charged particles. c- The TOF and associated trigger compose the third detecting sub-unit of the Mini-SPT , consisting basically of two small (~2 cm diameter) plastic scintillator layers The challenge is to develop a high performing scientific payload to fit in 6U Cubesat format with very good electron, proton and heavier particles separation as well as direct energy spectra measurement for protons up to almost 1 GeV and for electrons up to few tens of MeV. The angular acceptance of full mini-SPT payload is 6-5 degrees. If only tracking elements (SPDs) are considered the opening angle increases15 degrees.
Development and validation of the Overlap Muon Track Finder for the CMS experiment
NASA Astrophysics Data System (ADS)
Dobosz, J.; Mietki, P.; Zawistowski, K.; Żarnecki, G.
2016-09-01
Present article is a description of the authors contribution in upgrade and analysis of performance of the Level-1 Muon Trigger of the CMS experiment. The authors are students of University of Warsaw and Gdansk University of Technology. They are collaborating with the CMS Warsaw Group. This article summarises students' work presented during the Students session during the Workshop XXXVIII-th IEEE-SPIE Joint Symposium Wilga 2016. In the first section the CMS experiment is briefly described and the importance of the trigger system is explained. There is also shown basic difference between old muon trigger strategy and the upgraded one. The second section is devoted to Overlap Muon Track Finder (OMTF). This is one of the crucial components of the Level-1 Muon Trigger. The algorithm of OMTF is described. In the third section there is discussed one of the event selection aspects - cut on the muon transverse momentum pT . Sometimes physical muon with pT bigger than a certain threshold is unnecessarily cut and physical muon with lower pT survives. To improve pT selection modified algorithm was proposed and its performance was studied. One of the features of the OMTF is that one physical muon often results in several muon candidates. The Ghost-Buster algorithm is designed to eliminate surplus candidates. In the fourth section this algorithm and its performance on different data samples are discussed. In the fifth section Local Data Acquisition System (Local DAQ) is briefly described. It supports initial system commissioning. The test done with OMTF Local DAQ are described. In the sixth section there is described development of web application used for the control and monitoring of CMS electronics. The application provides access to graphical user interface for manual control and the connection to the CMS hierarchical Run Control.
Dantrolene mediates vasorelaxation in cerebral vasoconstriction - A Case Series
Muehlschlegel, Susanne; Rordorf, Guy; Bodock, Michael; Sims, John R.
2009-01-01
INTRODUCTION Cerebral vasoconstriction syndromes such as vasospasm after subarachnoid hemorrhage (SAH) and trauma, or Call-Fleming-Syndrome are difficult to treat, and can lead to substantial disability and death. Dantrolene, a ryanodine receptor antagonist, inhibits intracellular calcium release from the sarco-endoplasmic reticulum. We examined the effect of dantrolene on middle cerebral artery (MCA) blood flow velocities as measured by transcranial Doppler (TCD). METHODS Three consecutive patients with elevated MCA TCD velocities receiving dantrolene (2.5mg/kg IV q6h) were retrospectively reviewed. Average MCA peak systolic, mean flow velocities, and the pulsatility index (PI) before and after the dantrolene infusion were compared within patients. Systemic physiological parameters (blood pressure, heart rate, central venous pressure, intracranial pressure, body temperature and cooling water temperature) were recorded during 6 hours before and after the dantrolene infusion. RESULTS MCA peak systolic velocities (mean ± SE) for the three patients were 297 ± 3 cm/s, 248 ± 8 cm/s, and 268 ± 19 cm/s before dantrolene and 159 ± 9 cm/s, 169 ± 8 cm/s and 216 ± 12 cm/s after dantrolene. Average mean flow velocities showed the same trend. Interestingly, the PI increased slightly from 0.6, 0.52 and 0.67 before dantrolene, to 1.17, 0.71 and 0.77 after dantrolene. Systemic physiological parameters remained stable in all three patients. CONCLUSION Dantrolene attenuated cerebral vasoconstriction as measured by TCD without altering systemic physiological parameters. This suggests that intracellular calcium release from ryanodine channels in smooth muscle might play a role in vasospasm. A prospective study is underway to test this hypothesis. PMID:18696267
Challenges of small-pixel infrared detectors: a review.
Rogalski, A; Martyniuk, P; Kopytko, M
2016-04-01
In the last two decades, several new concepts for improving the performance of infrared detectors have been proposed. These new concepts particularly address the drive towards the so-called high operating temperature focal plane arrays (FPAs), aiming to increase detector operating temperatures, and as a consequence reduce the cost of infrared systems. In imaging systems with the above megapixel formats, pixel dimension plays a crucial role in determining critical system attributes such as system size, weight and power consumption (SWaP). The advent of smaller pixels has also resulted in the superior spatial and temperature resolution of these systems. Optimum pixel dimensions are limited by diffraction effects from the aperture, and are in turn wavelength-dependent. In this paper, the key challenges in realizing optimum pixel dimensions in FPA design including dark current, pixel hybridization, pixel delineation, and unit cell readout capacity are outlined to achieve a sufficiently adequate modulation transfer function for the ultra-small pitches involved. Both photon and thermal detectors have been considered. Concerning infrared photon detectors, the trade-offs between two types of competing technology-HgCdTe material systems and III-V materials (mainly barrier detectors)-have been investigated.
Spatial light modulator array with heat minimization and image enhancement features
Jain, Kanti [Briarcliff Manor, NY; Sweatt, William C [Albuquerque, NM; Zemel, Marc [New Rochelle, NY
2007-01-30
An enhanced spatial light modulator (ESLM) array, a microelectronics patterning system and a projection display system using such an ESLM for heat-minimization and resolution enhancement during imaging, and the method for fabricating such an ESLM array. The ESLM array includes, in each individual pixel element, a small pixel mirror (reflective region) and a much larger pixel surround. Each pixel surround includes diffraction-grating regions and resolution-enhancement regions. During imaging, a selected pixel mirror reflects a selected-pixel beamlet into the capture angle of a projection lens, while the diffraction grating of the pixel surround redirects heat-producing unused radiation away from the projection lens. The resolution-enhancement regions of selected pixels provide phase shifts that increase effective modulation-transfer function in imaging. All of the non-selected pixel surrounds redirect all radiation energy away from the projection lens. All elements of the ESLM are fabricated by deposition, patterning, etching and other microelectronic process technologies.
Modulation transfer function of a triangular pixel array detector.
Karimzadeh, Ayatollah
2014-07-01
The modulation transfer function (MTF) is the main parameter that is used to evaluate image quality in electro-optical systems. Detector sampling MTF in most electro-optical systems determines the cutoff frequency of the system. The MTF of the detector depends on its pixel shape. In this work, we calculated the MTF of a detector with an equilateral triangular pixel shape. Some new results were found in deriving the MTF for the equilateral triangular pixel shape.
ERIC Educational Resources Information Center
Heid, Susan D.
2007-01-01
It's near-impossible to think about course management systems (CMS) without thinking about innovation, collaboration, and the sharing of ideas across institutions and even from vendor to vendor. Yet, "the next step" in CMS now means distinctly different things to various colleges and universities as, going forward, they consider their…
Event Display for the Visualization of CMS Events
NASA Astrophysics Data System (ADS)
Bauerdick, L. A. T.; Eulisse, G.; Jones, C. D.; Kovalskyi, D.; McCauley, T.; Mrak Tadel, A.; Muelmenstaedt, J.; Osborne, I.; Tadel, M.; Tu, Y.; Yagil, A.
2011-12-01
During the last year the CMS experiment engaged in consolidation of its existing event display programs. The core of the new system is based on the Fireworks event display program which was by-design directly integrated with the CMS Event Data Model (EDM) and the light version of the software framework (FWLite). The Event Visualization Environment (EVE) of the ROOT framework is used to manage a consistent set of 3D and 2D views, selection, user-feedback and user-interaction with the graphics windows; several EVE components were developed by CMS in collaboration with the ROOT project. In event display operation simple plugins are registered into the system to perform conversion from EDM collections into their visual representations which are then managed by the application. Full event navigation and filtering as well as collection-level filtering is supported. The same data-extraction principle can also be applied when Fireworks will eventually operate as a service within the full software framework.
Keeper, D M; Kerrisk, K L; House, J K; Garcia, S C; Thomson, P
2017-09-01
To determine the management practices utilised in automatic milking systems (AMS) that affect reproductive management and performance and how these compare with the management practices used in regionally proximal conventional milking systems (CMS). This study examined demographic and management data from AMS and CMS dairy farms through a survey, with a specific focus on reproductive management procedures. Overall, responses from AMS and CMS dairy farms showed little difference in terms of respondent demographics, farm size, herd structure and most farm management strategies. AMS dairies were more likely to use activity meters or other electronic oestrus detection aids than CMS dairies (P < 0.001) and were also more likely to have changed to electronic recording systems (P = 0.007). Although many respondents indicated that they used key monitoring parameters to assess reproductive performance (e.g. days in milk, conception vs pregnancy rate etc.), the format of responses varied significantly, indicating a relatively widespread (among the respondents) lack of knowledge regarding the meaning and usage of some of these common parameters/terminology. Ultimately, reproductive management practices of AMS dairies were largely similar to those of CMS dairies, indicating that such practices can be implemented in a practical sense, even though the resultant reproductive performance is not yet understood. Understanding that the key reproductive management strategies do not need to change vastly is important to ensure that new adoptees are well informed. Further work is needed to objectively measure AMS performance to increase the knowledge base and generate the confidence that will facilitate further adoption of this innovation. © 2017 Australian Veterinary Association.
NASA Astrophysics Data System (ADS)
Baselmans, J. J. A.; Bueno, J.; Yates, S. J. C.; Yurduseven, O.; Llombart, N.; Karatsu, K.; Baryshev, A. M.; Ferrari, L.; Endo, A.; Thoen, D. J.; de Visser, P. J.; Janssen, R. M. J.; Murugesan, V.; Driessen, E. F. C.; Coiffard, G.; Martin-Pintado, J.; Hargrave, P.; Griffin, M.
2017-05-01
Aims: Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. Methods: The system combines a 961 pixel imaging array based upon Microwave Kinetic Inductance Detectors (MKIDs) with a readout system capable of reading out all pixels simultaneously with only one readout cable pair and a single cryogenic amplifier. We evaluate, in a representative environment, the system performance in terms of sensitivity, dynamic range, optical efficiency, cosmic ray rejection, pixel-pixel crosstalk and overall yield at an observation centre frequency of 850 GHz and 20% fractional bandwidth. Results: The overall system has an excellent sensitivity, with an average detector sensitivity < NEPdet> =3×10-19 WHz measured using a thermal calibration source. At a loading power per pixel of 50 fW we demonstrate white, photon noise limited detector noise down to 300 mHz. The dynamic range would allow the detection of 1 Jy bright sources within the field of view without tuning the readout of the detectors. The expected dead time due to cosmic ray interactions, when operated in an L2 or a similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel yield is 83% and the crosstalk between the pixels is <-30 dB. Conclusions: This demonstrates that MKID technology can provide multiplexing ratios on the order of a 1000 with state-of-the-art single pixel performance, and that the technology is now mature enough to be considered for future space based observatories and experiments.
Status and Construction of the Belle II DEPFET pixel system
NASA Astrophysics Data System (ADS)
Lütticke, Florian
2014-06-01
DEpleted P-channel Field Effect Transistor (DEPFET) active pixel detectors combine detection with a first amplification stage in a fully depleted detector, resulting in an superb signal-to-noise ratio even for thin sensors. Two layers of thin (75 micron) silicon DEPFET pixels will be used as the innermost vertex system, very close to the beam pipe in the Belle II detector at the SuperKEKB facility. The status of the 8 million DEPFET pixels detector, latest developments and current system tests will be discussed.
42 CFR 410.142 - CMS process for approving national accreditation organizations.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... (5) A description of the organization's data management and analysis system for its accreditation... organizations. 410.142 Section 410.142 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... Diabetes Self-Management Training and Diabetes Outcome Measurements § 410.142 CMS process for approving...
42 CFR 410.142 - CMS process for approving national accreditation organizations.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... (5) A description of the organization's data management and analysis system for its accreditation... organizations. 410.142 Section 410.142 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... Diabetes Self-Management Training and Diabetes Outcome Measurements § 410.142 CMS process for approving...
A performance summary of an advanced multifuel-capable combustion and melting system (CMS) for the vitrification of hazardous wastes is presented. Vortex Corporation has evaluated its patented CMS for use in the remediation of soils contaminated with heavy metals and radionuclid...
Proarrhythmia risk prediction using human induced pluripotent stem cell-derived cardiomyocytes.
Yamazaki, Daiju; Kitaguchi, Takashi; Ishimura, Masakazu; Taniguchi, Tomohiko; Yamanishi, Atsuhiro; Saji, Daisuke; Takahashi, Etsushi; Oguchi, Masao; Moriyama, Yuta; Maeda, Sanae; Miyamoto, Kaori; Morimura, Kaoru; Ohnaka, Hiroki; Tashibu, Hiroyuki; Sekino, Yuko; Miyamoto, Norimasa; Kanda, Yasunari
2018-04-01
Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) are expected to become a useful tool for proarrhythmia risk prediction in the non-clinical drug development phase. Several features including electrophysiological properties, ion channel expression profile and drug responses were investigated using commercially available hiPSC-CMs, such as iCell-CMs and Cor.4U-CMs. Although drug-induced arrhythmia has been extensively examined by microelectrode array (MEA) assays in iCell-CMs, it has not been fully understood an availability of Cor.4U-CMs for proarrhythmia risk. Here, we evaluated the predictivity of proarrhythmia risk using Cor.4U-CMs. MEA assay revealed linear regression between inter-spike interval and field potential duration (FPD). The hERG inhibitor E-4031 induced reverse-use dependent FPD prolongation. We next evaluated the proarrhythmia risk prediction by a two-dimensional map, which we have previously proposed. We determined the relative torsade de pointes risk score, based on the extent of FPD with Fridericia's correction (FPDcF) change and early afterdepolarization occurrence, and calculated the margins normalized to free effective therapeutic plasma concentrations. The drugs were classified into three risk groups using the two-dimensional map. This risk-categorization system showed high concordance with the torsadogenic information obtained by a public database CredibleMeds. Taken together, these results indicate that Cor.4U-CMs can be used for drug-induced proarrhythmia risk prediction. Copyright © 2018 The Authors. Production and hosting by Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Albayrak, Duygu; Yildirim, Zahide
2015-01-01
This study investigates students' involvement in Facebook® as a course management system (CMS), Facebook acceptance, and the relationships between the two. The study used Facebook as a CMS in two freshman courses and employed mixed method as part of an action-research approach. Forty-two students participated in the study, and 12 of those students…
Cytoplasmic male sterility (CMS) in hybrid breeding in field crops.
Bohra, Abhishek; Jha, Uday C; Adhimoolam, Premkumar; Bisht, Deepak; Singh, Narendra P
2016-05-01
A comprehensive understanding of CMS/Rf system enabled by modern omics tools and technologies considerably improves our ability to harness hybrid technology for enhancing the productivity of field crops. Harnessing hybrid vigor or heterosis is a promising approach to tackle the current challenge of sustaining enhanced yield gains of field crops. In the context, cytoplasmic male sterility (CMS) owing to its heritable nature to manifest non-functional male gametophyte remains a cost-effective system to promote efficient hybrid seed production. The phenomenon of CMS stems from a complex interplay between maternally-inherited (mitochondrion) and bi-parental (nucleus) genomic elements. In recent years, attempts aimed to comprehend the sterility-inducing factors (orfs) and corresponding fertility determinants (Rf) in plants have greatly increased our access to candidate genomic segments and the cloned genes. To this end, novel insights obtained by applying state-of-the-art omics platforms have substantially enriched our understanding of cytoplasmic-nuclear communication. Concomitantly, molecular tools including DNA markers have been implicated in crop hybrid breeding in order to greatly expedite the progress. Here, we review the status of diverse sterility-inducing cytoplasms and associated Rf factors reported across different field crops along with exploring opportunities for integrating modern omics tools with CMS-based hybrid breeding.
Cellular Manufacturing System with Dynamic Lot Size Material Handling
NASA Astrophysics Data System (ADS)
Khannan, M. S. A.; Maruf, A.; Wangsaputra, R.; Sutrisno, S.; Wibawa, T.
2016-02-01
Material Handling take as important role in Cellular Manufacturing System (CMS) design. In several study at CMS design material handling was assumed per pieces or with constant lot size. In real industrial practice, lot size may change during rolling period to cope with demand changes. This study develops CMS Model with Dynamic Lot Size Material Handling. Integer Linear Programming is used to solve the problem. Objective function of this model is minimizing total expected cost consisting machinery depreciation cost, operating costs, inter-cell material handling cost, intra-cell material handling cost, machine relocation costs, setup costs, and production planning cost. This model determines optimum cell formation and optimum lot size. Numerical examples are elaborated in the paper to ilustrate the characterictic of the model.
The CMS Level-1 trigger for LHC Run II
NASA Astrophysics Data System (ADS)
Tapper, A.
2018-02-01
During LHC Run II the centre-of-mass energy of pp collisions has increased from 8 TeV up to 13 TeV and the instantaneous luminosity has progressed towards 2 × 1034 cm-2s-1. In order to guarantee a successful and ambitious physics programme under these conditions, the CMS trigger system has been upgraded. The upgraded CMS Level-1 trigger is designed to improve performance at high luminosity and large number of simultaneous inelastic collisions per crossing. The trigger design, implementation and commissioning are summarised, and performance results are described.
CMS-2 Reverse Engineering and ENCORE/MODEL Integration
1992-05-01
Automated extraction of design information from an existing software system written in CMS-2 can be used to document that system as-built, and that I The...extracted information is provided by a commer- dally available CASE tool. * Information describing software system design is automatically extracted...the displays in Figures 1, 2, and 3. T achiev ths GE 11 b iuo w as rjcs CM-2t Aa nsltr(M2da 1 n Joia Reverse EwngiernTcnlg 5RT [2GRE] . Two xampe fD
Introducing Earthdata 3.0: An All-New Way of Creating and Publishing Content
NASA Astrophysics Data System (ADS)
Bagwell, R.; Wong, M. M.; Siarto, J.; Reese, M.; Berrick, S. W.
2015-12-01
Since the launch of the National Aeronautics and Space Administration (NASA) Earthdata website (https://earthdata.nasa.gov) in the later part of 2011, there has been an emphasis on improving the user experience and providing more enriched content to the user, ultimately with the focus to bring the "pixels to the people" or to ensure that a user clicks the fewest amount of times to get to the data, tools, or information which they seek. NASA Earthdata was founded to be a single source of information as a conglomeration between over 20 different websites. With an increased focus on access to Earth science data, the recognition is now on transforming Earthdata from a static website to one that is a dynamic, data-driven site full of enriched content. This poster will present the process of utilizing a custom-built Content Management System (CMS) called "Conduit" to manage and publish content into the new Earthdata website, with examples of the various components of the CMS, as well as featured areas from the new website design. NASA Earthdata is a part of the Earth Observing System Data and Information System (EOSDIS) project. EOSDIS is a key core capability in NASA's Earth Science Data Systems Program. It provides end-to-end capabilities for managing NASA's Earth science data from various sources - satellites, aircraft, field measurements, and various other programs. It is comprised of twelve Distributed Active Archive Centers (DAACs), Science Computing Facilities (SCFs), data discovery and service access client (Reverb and Earthdata Search), dataset directory (Global Change Master Directory - GCMD), near real-time data (Land Atmosphere Near real-time Capability for EOS - LANCE), Worldview (an imagery visualization interface), Global Imagery Browse Services, the Earthdata Code Collaborative and a host of other discipline specific data discovery, data access, data subsetting and visualization tools. In the near future, Earthdata will have a number of components that will drive the access to the data, such as the Earthdata Search Client and the Common Metadata Repository (CMR). The focus on content curation will be to leverage the use of these components to provide an enriched content environment and a better overall user experience, with an emphasis on Earthdata being "powered by EOSDIS" components and services.
Development of high energy micro-tomography system at SPring-8
NASA Astrophysics Data System (ADS)
Uesugi, Kentaro; Hoshino, Masato
2017-09-01
A high energy X-ray micro-tomography system has been developed at BL20B2 in SPring-8. The available range of the energy is between 20keV and 113keV with a Si (511) double crystal monochromator. The system enables us to image large or heavy materials such as fossils and metals. The X-ray image detector consists of visible light conversion system and sCMOS camera. The effective pixel size is variable by changing a tandem lens between 6.5 μm/pixel and 25.5 μm/pixel discretely. The format of the camera is 2048 pixels x 2048 pixels. As a demonstration of the system, alkaline battery and a nodule from Bolivia were imaged. A detail of the structure of the battery and a female mold Trilobite were successfully imaged without breaking those fossils.
1982-03-01
POSTGRADUATE SCHOOL fMonterey, California THESIS A VERSION OF THE GRAPHICS-ORIENTED INTERACTIVE FINITE ELEMENT TIME-SHARING SYSTEM ( GIFTS ) FOR AN IBM...Master’s & Engineer’s active Finite Element Time-sharing System Thesis - March 1982 ( GIFTS ) for an IBM with CP/CMS 6. penromm.oOn. REPoRT MUlmiR 1. AUTHOIee...ss0in D dinuf 5W M memisi) ’A version of the Graphics-oriented, Interactive, Finite element, Time-sharing System ( GIFTS ) has been developed for, and
USDA-ARS?s Scientific Manuscript database
All commercial sorghum (Sorghum bicolor L. Moench) hybrids are produced using A1 cytoplasmic male sterility (CMS) lines. However, this homogenous cytoplasm could predispose sorghum to devastating diseases. Furthermore, it is expensive to develop and maintain the CMS-based breeding system, because it...
Stability and Scalability of the CMS Global Pool: Pushing HTCondor and GlideinWMS to New Limits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balcas, J.; Bockelman, B.; Hufnagel, D.
The CMS Global Pool, based on HTCondor and glideinWMS, is the main computing resource provisioning system for all CMS workflows, including analysis, Monte Carlo production, and detector data reprocessing activities. The total resources at Tier-1 and Tier-2 grid sites pledged to CMS exceed 100,000 CPU cores, while another 50,000 to 100,000 CPU cores are available opportunistically, pushing the needs of the Global Pool to higher scales each year. These resources are becoming more diverse in their accessibility and configuration over time. Furthermore, the challenge of stably running at higher and higher scales while introducing new modes of operation such asmore » multi-core pilots, as well as the chaotic nature of physics analysis workflows, places huge strains on the submission infrastructure. This paper details some of the most important challenges to scalability and stability that the CMS Global Pool has faced since the beginning of the LHC Run II and how they were overcome.« less
CMS Distributed Computing Integration in the LHC sustained operations era
NASA Astrophysics Data System (ADS)
Grandi, C.; Bockelman, B.; Bonacorsi, D.; Fisk, I.; González Caballero, I.; Farina, F.; Hernández, J. M.; Padhi, S.; Sarkar, S.; Sciabà, A.; Sfiligoi, I.; Spiga, F.; Úbeda García, M.; Van Der Ster, D. C.; Zvada, M.
2011-12-01
After many years of preparation the CMS computing system has reached a situation where stability in operations limits the possibility to introduce innovative features. Nevertheless it is the same need of stability and smooth operations that requires the introduction of features that were considered not strategic in the previous phases. Examples are: adequate authorization to control and prioritize the access to storage and computing resources; improved monitoring to investigate problems and identify bottlenecks on the infrastructure; increased automation to reduce the manpower needed for operations; effective process to deploy in production new releases of the software tools. We present the work of the CMS Distributed Computing Integration Activity that is responsible for providing a liaison between the CMS distributed computing infrastructure and the software providers, both internal and external to CMS. In particular we describe the introduction of new middleware features during the last 18 months as well as the requirements to Grid and Cloud software developers for the future.
Stability and scalability of the CMS Global Pool: Pushing HTCondor and glideinWMS to new limits
NASA Astrophysics Data System (ADS)
Balcas, J.; Bockelman, B.; Hufnagel, D.; Hurtado Anampa, K.; Aftab Khan, F.; Larson, K.; Letts, J.; Marra da Silva, J.; Mascheroni, M.; Mason, D.; Perez-Calero Yzquierdo, A.; Tiradani, A.
2017-10-01
The CMS Global Pool, based on HTCondor and glideinWMS, is the main computing resource provisioning system for all CMS workflows, including analysis, Monte Carlo production, and detector data reprocessing activities. The total resources at Tier-1 and Tier-2 grid sites pledged to CMS exceed 100,000 CPU cores, while another 50,000 to 100,000 CPU cores are available opportunistically, pushing the needs of the Global Pool to higher scales each year. These resources are becoming more diverse in their accessibility and configuration over time. Furthermore, the challenge of stably running at higher and higher scales while introducing new modes of operation such as multi-core pilots, as well as the chaotic nature of physics analysis workflows, places huge strains on the submission infrastructure. This paper details some of the most important challenges to scalability and stability that the CMS Global Pool has faced since the beginning of the LHC Run II and how they were overcome.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adam, W.; Bergauer, T.; Brondolin, E.
The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment’s silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equivalent fluence of up tomore » $$\\Phi _{eq} = 2 \\times 10^{16}$$ cm$$^{-2}$$ , and an ionising dose of $${\\approx } 5$$ MGy after an integrated luminosity of 3000 fb$$^{-1}$$ . Thin, planar silicon sensors are good candidates for this application, since the degradation of the signal produced by traversing particles is less severe than for thicker devices. Here in this article, the results obtained from the characterisation of 100 and 200 μm thick p-bulk pad diodes and strip sensors irradiated up to fluences of $$\\Phi _{eq} = 1.3 \\times 10^{16}$$ cm$$^{-2}$$ are shown.« less
Measures of emergency preparedness contributing to nursing home resilience.
Lane, Sandi J; McGrady, Elizabeth
2017-12-13
Resilience approaches have been successfully applied in crisis management, disaster response, and high reliability organizations and have the potential to enhance existing systems of nursing home disaster preparedness. This study's purpose was to determine how the Center for Medicare and Medicaid Services (CMS) "Emergency Preparedness Checklist Recommended Tool for Effective Health Care Facility Planning" contributes to organizational resilience by identifying the benchmark resilience items addressed by the CMS Emergency Preparedness Checklist and items not addressed by the CMS Emergency Preparedness Checklist, and to recommend tools and processes to improve resilience for nursing homes. The CMS Emergency Preparedness Checklist items were compared to the Resilience Benchmark Tool items; similar items were considered matches. Resilience Benchmark Tool items with no CMS Emergency Preparedness Checklist item matches were considered breaches in nursing home resilience. The findings suggest that the CMS Emergency Preparedness Checklist can be used to measure some aspects of resilience, however, there were many resilience factors not addressed. For nursing homes to prepare and respond to crisis situations, organizations need to embrace a culture that promotes individual resilience-related competencies that when aggregated enable the organization to improve its resiliency. Social workers have the skills and experience to facilitate this change.
Wallace, Stephanie J; Li, Jian; Nation, Roger L; Prankerd, Richard J; Boyd, Ben J
2012-09-01
Interaction of colistin and colistin methanesulfonate (CMS) with liposomes has been studied with the view to understanding the limitations to the use of liposomes as a more effective delivery system for pulmonary inhalation of this important class of antibiotic. Thus, in this study, liposomes containing colistin or CMS were prepared and characterized with respect to colloidal behavior and drug encapsulation and release. Association of anionic CMS with liposomes induced negative charge on the particles. However, degradation of the CMS to form cationic colistin over time was directly correlated with charge reversal and particle aggregation. The rate of degradation of CMS was significantly more rapid when associated with the liposome bilayer than when compared with the same concentration in aqueous solution. Colistin liposomes carried positive charge and were stable. Encapsulation efficiency for colistin was approximately 50%, decreasing with increasing concentration of colistin. Colistin was rapidly released from liposomes on dilution. Although the studies indicate limited utility of colistin or CMS liposomes for long duration controlled-release applications, colistin liposomes were highly stable and may present a potential opportunity for coformulation of colistin with a second antibiotic to colocalize the two drugs after pulmonary delivery. Copyright © 2012 Wiley Periodicals, Inc.
Du, Fang; Hönzke, Stefan; Neumann, Falko; Keilitz, Juliane; Chen, Wei; Ma, Nan; Hedtrich, Sarah; Haag, Rainer
2016-11-28
The topical application of drugs allows for a local application in skin disease and can reduce side effects. Here we present biodegradable core-multishell (CMS) nanocarriers which are composed of a hyperbranched polyglycerol core functionalized with diblock copolymers consisting of polycaprolactone (PCL) and poly(ethylene glycol) (mPEG) as the outer shell. The anti-inflammatory drug Dexamethasone (Dexa) was loaded into these CMS nanocarriers. DLS results suggested that Dexa loaded nanoparticles mostly act as a unimolecular carrier system. With longer PCL segments, a better transport capacity is observed. In vitro skin permeation studies showed that CMS nanocarriers could improve the Nile red penetration through the skin by up to 7 times, compared to a conventional cream formulation. Interestingly, covalently FITC-labeled CMS nanocarriers remain in the stratum corneum layer. This suggests the enhancement is due to the release of cargo after being transported into the stratum corneum by the CMS nanocarriers. In addition, the hPG-PCL-mPEG CMS nanocarriers exhibited good stability, low cytotoxicity, and their production can easily be scaled up, which makes them promising nanocarriers for topical drug delivery. Copyright © 2016 Elsevier B.V. All rights reserved.
WALLACE, STEPHANIE J.; LI, JIAN; NATION, ROGER L.; PRANKERD, RICHARD J.; BOYD, BEN J.
2012-01-01
Interaction of colistin and colistin methanesulfonate (CMS) with liposomes has been studied with the view to understanding the limitations to the use of liposomes as a more effective delivery system for pulmonary inhalation of this important class of antibiotic. Thus, in this study, liposomes containing colistin or CMS were prepared and characterized with respect to colloidal behavior and drug encapsulation and release. Association of anionic CMS with liposomes induced negative charge on the particles. However, degradation of the CMS to form cationic colistin over time was directly correlated with charge reversal and particle aggregation. The rate of degradation of CMS was significantly more rapid when associated with the liposome bilayer than when compared with the same concentration in aqueous solution. Colistin liposomes carried positive charge and were stable. Encapsulation efficiency for colistin was approximately 50%, decreasing with increasing concentration of colistin. Colistin was rapidly released from liposomes on dilution. Although the studies indicate limited utility of colistin or CMS liposomes for long duration controlled-release applications, colistin liposomes were highly stable and may present a potential opportunity for coformulation of colistin with a second antibiotic to colocalize the two drugs after pulmonary delivery. PMID:22623044
Rexhaj, Emrush; Rimoldi, Stefano F; Pratali, Lorenza; Brenner, Roman; Andries, Daniela; Soria, Rodrigo; Salinas, Carlos; Villena, Mercedes; Romero, Catherine; Allemann, Yves; Lovis, Alban; Heinzer, Raphaël; Sartori, Claudio; Scherrer, Urs
2016-04-01
Chronic mountain sickness (CMS) is often associated with vascular dysfunction, but the underlying mechanism is unknown. Sleep-disordered breathing (SDB) frequently occurs at high altitude. At low altitude, SDB causes vascular dysfunction. Moreover, in SDB, transient elevations of right-sided cardiac pressure may cause right-to-left shunting in the presence of a patent foramen ovale (PFO) and, in turn, further aggravate hypoxemia and pulmonary hypertension. We speculated that SDB and nocturnal hypoxemia are more pronounced in patients with CMS compared with healthy high-altitude dwellers, and are related to vascular dysfunction. We performed overnight sleep recordings, and measured systemic and pulmonary artery pressure in 23 patients with CMS (mean ± SD age, 52.8 ± 9.8 y) and 12 healthy control subjects (47.8 ± 7.8 y) at 3,600 m. In a subgroup of 15 subjects with SDB, we assessed the presence of a PFO with transesophageal echocardiography. The major new findings were that in patients with CMS, (1) SDB and nocturnal hypoxemia was more severe (P < .01) than in control subjects (apnea-hypopnea index [AHI], 38.9 ± 25.5 vs 14.3 ± 7.8 number of events per hour [nb/h]; arterial oxygen saturation, 80.2% ± 3.6% vs 86.8% ± 1.7%, CMS vs control group), and (2) AHI was directly correlated with systemic blood pressure (r = 0.5216; P = .001) and pulmonary artery pressure (r = 0.4497; P = .024). PFO was associated with more severe SDB (AHI, 48.8 ± 24.7 vs 14.8 ± 7.3 nb/h; P = .013, PFO vs no PFO) and hypoxemia. SDB and nocturnal hypoxemia are more severe in patients with CMS than in control subjects and are associated with systemic and pulmonary vascular dysfunction. The presence of a PFO appeared to further aggravate SDB. Closure of the PFO may improve SDB, hypoxemia, and vascular dysfunction in patients with CMS. ClinicalTrials.gov; No.: NCT01182792; URL: www.clinicaltrials.gov. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Upgrade fo the CMS Hadron Outer Calorimeter with SIPMs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Jacob; Freeman, James; Los, Sergey
2011-09-14
The CMS Hadron Outer Calorimeter (HO) is undergoing an upgrade to replace the existing photodetectors (HPDs) with SIPMs. The chosen device is the Hamamatsu 3 x 3mm 50 {mu}m pitch MPPC. The system has been developed to be a 'drop-in' replacement of the HPDs. A complete control system of bias voltage generation, leakage current monitoring, temperature monitoring, and temperature control using solid state Peltier coolers has been developed and tested. 108 channels of the system have been installed into CMS and operated for more than 2 years. The complete system of about 2200 channels is in production and will bemore » installed in the next LHC long shutdown scheduled for 2013. The CMS central calorimeter consists of a detector inside the solenoidal magnet, HB, and a component outside the magnet, the Outer Hadron Calorimeter, HO [1]. The HO is installed inside the magnet flux return yoke and provides for typically 3{lambda} of additional absorber to the calorimetric measurement. The outer calorimeter is composed of one or more layers of scintillator with wavelength shifting fiber readout into photodetectors. Figure 1 (a) shows the schematic layout of the calorimeters in CMS and shows the location of the HO scintillator layers. The front end electronics are placed inside the CMS detector, close to the scintillators. Figure 1(b) shows a photograph of the scintillators. Note the four wavelength shifting fibers per tile. The tile size creates a projective tower with the HB. Currently the photodetector used is the HPD but for performance and operational reasons it is desired to upgrade these with SIPMs. The CMS HCAL group has developed a drop-in replacement for the HPD using SIPMs. SIPMs are very suitable for this application because of several factors: The radiation levels are modest with a lifetime expected fluence of less than 5*10{sup 11} neutrons (E > 100 KeV) per cm{sup 2}. The energy flux into HO is small, the rate of larger energy depositions is low, and the required dynamic range is modest. The HO is in the return magnetic field of up to 2KG and the photodetector needs to operate in that environment. Finally, the available physical volume for the photodetectors is small.« less
CMS proposes to OK one-midnight inpatient stays.
2015-09-01
The Centers for Medicare & Medicaid Services (CMS) has proposed that stays shorter than two midnights be reimbursed as inpatient stays if the documentation in the medical record supports it. CMS made the proposal in the Outpatient Prospective Payment System proposed rule for 2016 and left the policy unchanged for stays of two midnights or longer. CMS also announced that the two Beneficiary and Family Centered Care Quality Improvement Organizations (QIOs), Livanta and KEPRO, will take over the responsibility of Probe and Educate and will review cases for medical necessity when patient stays are one midnight or less, referring hospitals with high denial rates to the Recovery Auditors. Case managers should continue to assist physicians in determining patient status and to make sure that the documentation is complete, accurate, and specifies the severity of illness.
ERIC Educational Resources Information Center
Chamberlain, Ed
A cost benefit study was conducted to determine the effectiveness of a computer assisted instruction/computer management system (CAI/CMS) as an alternative to conventional methods of teaching reading within Chapter 1 and DPPF funded programs of the Columbus (Ohio) Public Schools. The Chapter 1 funded Compensatory Language Experiences and Reading…
Sirunyan, Albert M; et al.
2018-06-19
The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energymore » $$\\sqrt{s}=$$ 13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.« less
NASA Astrophysics Data System (ADS)
Sipos, Roland; Govi, Giacomo; Franzoni, Giovanni; Di Guida, Salvatore; Pfeiffer, Andreas
2017-10-01
The CMS experiment at CERN LHC has a dedicated infrastructure to handle the alignment and calibration data. This infrastructure is composed of several services, which take on various data management tasks required for the consumption of the non-event data (also called as condition data) in the experiment activities. The criticality of these tasks imposes tights requirements for the availability and the reliability of the services executing them. In this scope, a comprehensive monitoring and alarm generating system has been developed. The system has been implemented based on the Nagios open source industry standard for monitoring and alerting services, and monitors the database back-end, the hosting nodes and key heart-beat functionalities for all the services involved. This paper describes the design, implementation and operational experience with the monitoring system developed and deployed at CMS in 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sirunyan, Albert M; et al.
The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energymore » $$\\sqrt{s}=$$ 13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.« less
The Level 0 Pixel Trigger system for the ALICE experiment
NASA Astrophysics Data System (ADS)
Aglieri Rinella, G.; Kluge, A.; Krivda, M.; ALICE Silicon Pixel Detector project
2007-01-01
The ALICE Silicon Pixel Detector contains 1200 readout chips. Fast-OR signals indicate the presence of at least one hit in the 8192 pixel matrix of each chip. The 1200 bits are transmitted every 100 ns on 120 data readout optical links using the G-Link protocol. The Pixel Trigger System extracts and processes them to deliver an input signal to the Level 0 trigger processor targeting a latency of 800 ns. The system is compact, modular and based on FPGA devices. The architecture allows the user to define and implement various trigger algorithms. The system uses advanced 12-channel parallel optical fiber modules operating at 1310 nm as optical receivers and 12 deserializer chips closely packed in small area receiver boards. Alternative solutions with multi-channel G-Link deserializers implemented directly in programmable hardware devices were investigated. The design of the system and the progress of the ALICE Pixel Trigger project are described in this paper.
NASA Technical Reports Server (NTRS)
Myers, W. L.
1981-01-01
The LANDSAT-geographic information system (GIS) interface must summarize the results of the LANDSAT classification over the same cells that serve as geographic referencing units for the GIS, and output these summaries on a cell-by-cell basis in a form that is readable by the input routines of the GIS. The ZONAL interface for cell-oriented systems consists of two primary programs. The PIXCEL program scans the grid of cells and outputs a channel of pixels. Each pixel contains not the reflectance values but the identifier of the cell in which the center of the pixel is located. This file of pixelized cells along with the results of a pixel-by-pixel classification of the scene produced by the LANDSAT analysis system are input to the CELSUM program which then outputs a cell-by-cell summary formatted according to the requirements of the host GIS. Cross-correlation of the LANDSAT layer with the other layers in the data base is accomplished with the analysis and display facilities of the GIS.
NASA Technical Reports Server (NTRS)
Howard, Richard T. (Inventor); Bryan, ThomasC. (Inventor); Book, Michael L. (Inventor)
2004-01-01
A method and system for processing an image including capturing an image and storing the image as image pixel data. Each image pixel datum is stored in a respective memory location having a corresponding address. Threshold pixel data is selected from the image pixel data and linear spot segments are identified from the threshold pixel data selected.. Ihe positions of only a first pixel and a last pixel for each linear segment are saved. Movement of one or more objects are tracked by comparing the positions of fust and last pixels of a linear segment present in the captured image with respective first and last pixel positions in subsequent captured images. Alternatively, additional data for each linear data segment is saved such as sum of pixels and the weighted sum of pixels i.e., each threshold pixel value is multiplied by that pixel's x-location).
Huang, Yi-Wen; Roa, Juan C.; Goodfellow, Paul J.; Kizer, E. Lynette; Huang, Tim H. M.; Chen, Yidong
2013-01-01
Background DNA methylation of promoter CpG islands is associated with gene suppression, and its unique genome-wide profiles have been linked to tumor progression. Coupled with high-throughput sequencing technologies, it can now efficiently determine genome-wide methylation profiles in cancer cells. Also, experimental and computational technologies make it possible to find the functional relationship between cancer-specific methylation patterns and their clinicopathological parameters. Methodology/Principal Findings Cancer methylome system (CMS) is a web-based database application designed for the visualization, comparison and statistical analysis of human cancer-specific DNA methylation. Methylation intensities were obtained from MBDCap-sequencing, pre-processed and stored in the database. 191 patient samples (169 tumor and 22 normal specimen) and 41 breast cancer cell-lines are deposited in the database, comprising about 6.6 billion uniquely mapped sequence reads. This provides comprehensive and genome-wide epigenetic portraits of human breast cancer and endometrial cancer to date. Two views are proposed for users to better understand methylation structure at the genomic level or systemic methylation alteration at the gene level. In addition, a variety of annotation tracks are provided to cover genomic information. CMS includes important analytic functions for interpretation of methylation data, such as the detection of differentially methylated regions, statistical calculation of global methylation intensities, multiple gene sets of biologically significant categories, interactivity with UCSC via custom-track data. We also present examples of discoveries utilizing the framework. Conclusions/Significance CMS provides visualization and analytic functions for cancer methylome datasets. A comprehensive collection of datasets, a variety of embedded analytic functions and extensive applications with biological and translational significance make this system powerful and unique in cancer methylation research. CMS is freely accessible at: http://cbbiweb.uthscsa.edu/KMethylomes/. PMID:23630576
Gu, Fei; Doderer, Mark S; Huang, Yi-Wen; Roa, Juan C; Goodfellow, Paul J; Kizer, E Lynette; Huang, Tim H M; Chen, Yidong
2013-01-01
DNA methylation of promoter CpG islands is associated with gene suppression, and its unique genome-wide profiles have been linked to tumor progression. Coupled with high-throughput sequencing technologies, it can now efficiently determine genome-wide methylation profiles in cancer cells. Also, experimental and computational technologies make it possible to find the functional relationship between cancer-specific methylation patterns and their clinicopathological parameters. Cancer methylome system (CMS) is a web-based database application designed for the visualization, comparison and statistical analysis of human cancer-specific DNA methylation. Methylation intensities were obtained from MBDCap-sequencing, pre-processed and stored in the database. 191 patient samples (169 tumor and 22 normal specimen) and 41 breast cancer cell-lines are deposited in the database, comprising about 6.6 billion uniquely mapped sequence reads. This provides comprehensive and genome-wide epigenetic portraits of human breast cancer and endometrial cancer to date. Two views are proposed for users to better understand methylation structure at the genomic level or systemic methylation alteration at the gene level. In addition, a variety of annotation tracks are provided to cover genomic information. CMS includes important analytic functions for interpretation of methylation data, such as the detection of differentially methylated regions, statistical calculation of global methylation intensities, multiple gene sets of biologically significant categories, interactivity with UCSC via custom-track data. We also present examples of discoveries utilizing the framework. CMS provides visualization and analytic functions for cancer methylome datasets. A comprehensive collection of datasets, a variety of embedded analytic functions and extensive applications with biological and translational significance make this system powerful and unique in cancer methylation research. CMS is freely accessible at: http://cbbiweb.uthscsa.edu/KMethylomes/.
High throughput reconfigurable data analysis system
NASA Technical Reports Server (NTRS)
Bearman, Greg (Inventor); Pelletier, Michael J. (Inventor); Seshadri, Suresh (Inventor); Pain, Bedabrata (Inventor)
2008-01-01
The present invention relates to a system and method for performing rapid and programmable analysis of data. The present invention relates to a reconfigurable detector comprising at least one array of a plurality of pixels, where each of the plurality of pixels can be selected to receive and read-out an input. The pixel array is divided into at least one pixel group for conducting a common predefined analysis. Each of the pixels has a programmable circuitry programmed with a dynamically configurable user-defined function to modify the input. The present detector also comprises a summing circuit designed to sum the modified input.
Supervised pixel classification using a feature space derived from an artificial visual system
NASA Technical Reports Server (NTRS)
Baxter, Lisa C.; Coggins, James M.
1991-01-01
Image segmentation involves labelling pixels according to their membership in image regions. This requires the understanding of what a region is. Using supervised pixel classification, the paper investigates how groups of pixels labelled manually according to perceived image semantics map onto the feature space created by an Artificial Visual System. Multiscale structure of regions are investigated and it is shown that pixels form clusters based on their geometric roles in the image intensity function, not by image semantics. A tentative abstract definition of a 'region' is proposed based on this behavior.
Jouni, Mariam; Si-Tayeb, Karim; Es-Salah-Lamoureux, Zeineb; Latypova, Xenia; Champon, Benoite; Caillaud, Amandine; Rungoat, Anais; Charpentier, Flavien; Loussouarn, Gildas; Baró, Isabelle; Zibara, Kazem; Lemarchand, Patricia; Gaborit, Nathalie
2015-09-01
Human genetically inherited cardiac diseases have been studied mainly in heterologous systems or animal models, independent of patients' genetic backgrounds. Because sources of human cardiomyocytes (CMs) are extremely limited, the use of urine samples to generate induced pluripotent stem cell-derived CMs would be a noninvasive method to identify cardiac dysfunctions that lead to pathologies within patients' specific genetic backgrounds. The objective was to validate the use of CMs differentiated from urine-derived human induced pluripotent stem (UhiPS) cells as a new cellular model for studying patients' specific arrhythmia mechanisms. Cells obtained from urine samples of a patient with long QT syndrome who harbored the HERG A561P gene mutation and his asymptomatic noncarrier mother were reprogrammed using the episomal-based method. UhiPS cells were then differentiated into CMs using the matrix sandwich method.UhiPS-CMs showed proper expression of atrial and ventricular myofilament proteins and ion channels. They were electrically functional, with nodal-, atrial- and ventricular-like action potentials recorded using high-throughput optical and patch-clamp techniques. Comparison of HERG expression from the patient's UhiPS-CMs to the mother's UhiPS-CMs showed that the mutation led to a trafficking defect that resulted in reduced delayed rectifier K(+) current (IKr). This phenotype gave rise to action potential prolongation and arrhythmias. UhiPS cells from patients carrying ion channel mutations can be used as novel tools to differentiate functional CMs that recapitulate cardiac arrhythmia phenotypes. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
W. S. Yapa, Shalini; Li, Jian; Porter, Christopher J. H.; Nation, Roger L.
2013-01-01
Colistin methanesulfonate (CMS), the inactive prodrug of colistin, is administered by inhalation for the management of respiratory infections. However, limited pharmacokinetic data are available for CMS and colistin following pulmonary delivery. This study investigates the pharmacokinetics of CMS and colistin following intravenous (i.v.) and intratracheal (i.t.) administration in rats and determines the targeting advantage after direct delivery into the lungs. In addition to plasma, bronchoalveolar lavage (BAL) fluid was collected to quantify drug concentrations in lung epithelial lining fluid (ELF). The resulting data were analyzed using a population modeling approach in S-ADAPT. A three-compartment model described the disposition of both compounds in plasma following i.v. administration. The estimated mean clearance from the central compartment was 0.122 liters/h for CMS and 0.0657 liters/h for colistin. Conversion of CMS to colistin from all three compartments was required to fit the plasma data. The fraction of the i.v. dose converted to colistin in the systemic circulation was 0.0255. Two BAL fluid compartments were required to reflect drug kinetics in the ELF after i.t. dosing. A slow conversion of CMS (mean conversion time [MCTCMS] = 3.48 h) in the lungs contributed to high and sustained concentrations of colistin in ELF. The fraction of the CMS dose converted to colistin in ELF (fm,ELF = 0.226) was higher than the corresponding fractional conversion in plasma after i.v. administration. In conclusion, pulmonary administration of CMS achieves high and sustained exposures of colistin in lungs for targeting respiratory infections. PMID:23917323
NASA Astrophysics Data System (ADS)
Sepulveda Carlo, E.; Escobar, V. M.; Delgado Arias, S.; Forgotson, C.
2017-12-01
The NASA Carbon Monitoring System initiated by U.S. Congress in 2010 is developing products that characterize and quantify carbon sources and sinks in the United States and the global tropics. In 2013, an applications effort was selected to engage potential end users and gather feedback about their data needs. For the past four years the CMS applications efforts has expanded and implemented a number of strategies to connect carbon scientists to decision-makers, contributing to the societal benefits of CMS data products. The applications efforts use crowd sourcing to collects feedback from stakeholders on challenges and lessons learned in the use of CMS data products. Some of the most common data needs from engaged organizations include above and below-ground biomass and fluxes in forestlands and wetlands, and greenhouse gas (GHG) emissions across all land use/cover and land use changes. Stakeholder organizations' needs for CMS data products support national GHG inventories following the Paris Agreement, carbon markets, and sub-national natural resources management and policies. The lessons learned report presents stakeholder specific applications, challenges, and successes from using CMS data products. To date, the most common uses of CMS products include: conservation efforts, emissions inventory, forestry and land cover applications, and carbon offset projects. The most common challenges include: the need for familiar and consistent products over time, budget constraints, and concern with uncertainty of modeled results. Recurrent recommendations from stakeholder indicate that CMS should provide high resolution (30m) and frequent data products updates (annually). The applications efforts have also helped identified success stories from different CMS projects, including the development of the GHG emissions inventory from Providence, RI, the improvement of the U.S. GHG Inventory though the use of satellite data, and the use of high resolution canopy cover maps for forestry, conservation, and ecosystem services applications in the tristate area of Maryland, Delaware and Pennsylvania. The presentation will discuss the applications framework methodology and strategy, as well as highlight some of the results and lessons learned from these applications efforts.
Barriers Regarding Using Technology
ERIC Educational Resources Information Center
Boekenoogen, John Russell
2014-01-01
The University of Florida (UF) used an open-source course management system (CMS) called Sakai. Sakai was the fourth CMS the university has used to help teach live, blended (or hybrid), and online courses over the past ten years. The objective of this dissertation was to identify what barriers may be preventing university personnel from using…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-03
..., Department of Health and Human Services, Attention: CMS-1599-IFC, P.O. Box 8013, Baltimore, MD 21244-8013... for Medicare & Medicaid Services, Department of Health and Human Services, Attention: CMS-1599-IFC... receive Supplemental Security Income (SSI) benefits and their Medicaid utilization. Under section 1886(r...
76 FR 9579 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-18
... Enrollment, Chain and Ownership System (PECOS) Security Consent Form; Use: The primary function of the... proposed information collection for the proper performance of the Agency's function; (2) the accuracy of.... Form CMS-37 is the primary document used by CMS in developing the national Medicaid budget estimates...
Exploiting volatile opportunistic computing resources with Lobster
NASA Astrophysics Data System (ADS)
Woodard, Anna; Wolf, Matthias; Mueller, Charles; Tovar, Ben; Donnelly, Patrick; Hurtado Anampa, Kenyi; Brenner, Paul; Lannon, Kevin; Hildreth, Mike; Thain, Douglas
2015-12-01
Analysis of high energy physics experiments using the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) can be limited by availability of computing resources. As a joint effort involving computer scientists and CMS physicists at Notre Dame, we have developed an opportunistic workflow management tool, Lobster, to harvest available cycles from university campus computing pools. Lobster consists of a management server, file server, and worker processes which can be submitted to any available computing resource without requiring root access. Lobster makes use of the Work Queue system to perform task management, while the CMS specific software environment is provided via CVMFS and Parrot. Data is handled via Chirp and Hadoop for local data storage and XrootD for access to the CMS wide-area data federation. An extensive set of monitoring and diagnostic tools have been developed to facilitate system optimisation. We have tested Lobster using the 20 000-core cluster at Notre Dame, achieving approximately 8-10k tasks running simultaneously, sustaining approximately 9 Gbit/s of input data and 340 Mbit/s of output data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khachatryan, Vardan
This paper describes the CMS trigger system and its performance during Run 1 of the LHC. The trigger system consists of two levels designed to select events of potential physics interest from a GHz (MHz) interaction rate of proton-proton (heavy ion) collisions. The first level of the trigger is implemented in hardware, and selects events containing detector signals consistent with an electron, photon, muon, tau lepton, jet, or missing transverse energy. A programmable menu of up to 128 object-based algorithms is used to select events for subsequent processing. The trigger thresholds are adjusted to the LHC instantaneous luminosity during datamore » taking in order to restrict the output rate to 100 kHz, the upper limit imposed by the CMS readout electronics. The second level, implemented in software, further refines the purity of the output stream, selecting an average rate of 400 Hz for offline event storage. The objectives, strategy and performance of the trigger system during the LHC Run 1 are described.« less
NASA Astrophysics Data System (ADS)
Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Hartl, C.; Hörmann, N.; Hrubec, J.; Jeitler, M.; Knünz, V.; König, A.; Krammer, M.; Krätschmer, I.; Liko, D.; Matsushita, T.; Mikulec, I.; Rabady, D.; Rahbaran, B.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Strauss, J.; Treberer-Treberspurg, W.; Waltenberger, W.; Wulz, C.-E.; Mossolov, V.; Shumeiko, N.; Suarez Gonzalez, J.; Alderweireldt, S.; Cornelis, T.; De Wolf, E. A.; Janssen, X.; Knutsson, A.; Lauwers, J.; Luyckx, S.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Van Spilbeeck, A.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; Daci, N.; De Bruyn, I.; Deroover, K.; Heracleous, N.; Keaveney, J.; Lowette, S.; Moreels, L.; Olbrechts, A.; Python, Q.; Strom, D.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Onsem, G. P.; Van Parijs, I.; Barria, P.; Brun, H.; Caillol, C.; Clerbaux, B.; De Lentdecker, G.; Fasanella, G.; Favart, L.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Léonard, A.; Maerschalk, T.; Marinov, A.; Perniè, L.; Randle-conde, A.; Reis, T.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Yonamine, R.; Zenoni, F.; Zhang, F.; Beernaert, K.; Benucci, L.; Cimmino, A.; Crucy, S.; Dobur, D.; Fagot, A.; Garcia, G.; Gul, M.; Mccartin, J.; Ocampo Rios, A. A.; Poyraz, D.; Ryckbosch, D.; Salva, S.; Sigamani, M.; Strobbe, N.; Tytgat, M.; Van Driessche, W.; Yazgan, E.; Zaganidis, N.; Basegmez, S.; Beluffi, C.; Bondu, O.; Brochet, S.; Bruno, G.; Caudron, A.; Ceard, L.; Da Silveira, G. G.; Delaere, C.; Favart, D.; Forthomme, L.; Giammanco, A.; Hollar, J.; Jafari, A.; Jez, P.; Komm, M.; Lemaitre, V.; Mertens, A.; Musich, M.; Nuttens, C.; Perrini, L.; Pin, A.; Piotrzkowski, K.; Popov, A.; Quertenmont, L.; Selvaggi, M.; Vidal Marono, M.; Beliy, N.; Hammad, G. H.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Hamer, M.; Hensel, C.; Mora Herrera, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Custódio, A.; Da Costa, E. M.; Damiao, D. De Jesus; De Oliveira Martins, C.; Fonseca De Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Matos Figueiredo, D.; Mundim, L.; Nogima, H.; Prado Da Silva, W. L.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; De Souza Santos, A.; Dogra, S.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Moon, C. S.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Rodozov, M.; Stoykova, S.; Sultanov, G.; Vutova, M.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Cheng, T.; Du, R.; Jiang, C. H.; Plestina, R.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Zhang, H.; Asawatangtrakuldee, C.; Ban, Y.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; Gomez, J. P.; Gomez Moreno, B.; Sanabria, J. C.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Kadija, K.; Luetic, J.; Micanovic, S.; Sudic, L.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Bodlak, M.; Finger, M.; Finger, M., Jr.; Assran, Y.; El Sawy, M.; Elgammal, S.; Ellithi Kamel, A.; Mahmoud, M. A.; Calpas, B.; Kadastik, M.; Murumaa, M.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Mäenpää, T.; Peltola, T.; Tuominen, E.; Tuominiemi, J.; Tuovinen, E.; Wendland, L.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Fabbro, B.; Faure, J. L.; Favaro, C.; Ferri, F.; Ganjour, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Locci, E.; Machet, M.; Malcles, J.; Rander, J.; Rosowsky, A.; Titov, M.; Zghiche, A.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Chapon, E.; Charlot, C.; Dahms, T.; Davignon, O.; Filipovic, N.; Florent, A.; Granier de Cassagnac, R.; Lisniak, S.; Mastrolorenzo, L.; Miné, P.; Naranjo, I. N.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Regnard, S.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Agram, J.-L.; Andrea, J.; Aubin, A.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Goetzmann, C.; Le Bihan, A.-C.; Merlin, J. A.; Skovpen, K.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Bouvier, E.; Carrillo Montoya, C. A.; Chierici, R.; Contardo, D.; Courbon, B.; Depasse, P.; El Mamouni, H.; Fan, J.; Fay, J.; Gascon, S.; Gouzevitch, M.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Ruiz Alvarez, J. D.; Sabes, D.; Sgandurra, L.; Sordini, V.; Vander Donckt, M.; Verdier, P.; Viret, S.; Toriashvili, T.; Tsamalaidze, Z.; Autermann, C.; Beranek, S.; Edelhoff, M.; Feld, L.; Heister, A.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Ostapchuk, A.; Preuten, M.; Raupach, F.; Schael, S.; Schulte, J. F.; Verlage, T.; Weber, H.; Wittmer, B.; Zhukov, V.; Ata, M.; Brodski, M.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Klingebiel, D.; Knutzen, S.; Kreuzer, P.; Merschmeyer, M.; Meyer, A.; Millet, P.; Olschewski, M.; Padeken, K.; Papacz, P.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Sonnenschein, L.; Teyssier, D.; Thüer, S.; Cherepanov, V.; Erdogan, Y.; Flügge, G.; Geenen, H.; Geisler, M.; Hoehle, F.; Kargoll, B.; Kress, T.; Kuessel, Y.; Künsken, A.; Lingemann, J.; Nehrkorn, A.; Nowack, A.; Nugent, I. M.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Asin, I.; Bartosik, N.; Behnke, O.; Behrens, U.; Bell, A. J.; Borras, K.; Burgmeier, A.; Campbell, A.; Choudhury, S.; Costanza, F.; Diez Pardos, C.; Dolinska, G.; Dooling, S.; Dorland, T.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Flucke, G.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Gunnellini, P.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Karacheban, O.; Kasemann, M.; Katsas, P.; Kieseler, J.; Kleinwort, C.; Korol, I.; Lange, W.; Leonard, J.; Lipka, K.; Lobanov, A.; Lohmann, W.; Mankel, R.; Marfin, I.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Naumann-Emme, S.; Nayak, A.; Ntomari, E.; Perrey, H.; Pitzl, D.; Placakyte, R.; Raspereza, A.; Roland, B.; Sahin, M. Ö.; Saxena, P.; Schoerner-Sadenius, T.; Schröder, M.; Seitz, C.; Spannagel, S.; Trippkewitz, K. D.; Walsh, R.; Wissing, C.; Blobel, V.; Centis Vignali, M.; Draeger, A. R.; Erfle, J.; Garutti, E.; Goebel, K.; Gonzalez, D.; Görner, M.; Haller, J.; Hoffmann, M.; Höing, R. S.; Junkes, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Lapsien, T.; Lenz, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Nowatschin, D.; Ott, J.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Pietsch, N.; Poehlsen, J.; Rathjens, D.; Sander, C.; Scharf, C.; Schettler, H.; Schleper, P.; Schlieckau, E.; Schmidt, A.; Schwandt, J.; Sola, V.; Stadie, H.; Steinbrück, G.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Akbiyik, M.; Barth, C.; Baus, C.; Berger, J.; Böser, C.; Butz, E.; Chwalek, T.; Colombo, F.; De Boer, W.; Descroix, A.; Dierlamm, A.; Fink, S.; Frensch, F.; Friese, R.; Giffels, M.; Gilbert, A.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Katkov, I.; Kornmayer, A.; Lobelle Pardo, P.; Maier, B.; Mildner, H.; Mozer, M. U.; Müller, T.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Röcker, S.; Roscher, F.; Sieber, G.; Simonis, H. J.; Stober, F. M.; Ulrich, R.; Wagner-Kuhr, J.; Wayand, S.; Weber, M.; Weiler, T.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Psallidas, A.; Topsis-Giotis, I.; Agapitos, A.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Tziaferi, E.; Evangelou, I.; Flouris, G.; Foudas, C.; Kokkas, P.; Loukas, N.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Bencze, G.; Hajdu, C.; Hazi, A.; Hidas, P.; Horvath, D.; Sikler, F.; Veszpremi, V.; Vesztergombi, G.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Molnar, J.; Szillasi, Z.; Bartók, M.; Makovec, A.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Mal, P.; Mandal, K.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chawla, R.; Gupta, R.; Bhawandeep, U.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Mehta, A.; Mittal, M.; Singh, J. B.; Walia, G.; Kumar, Ashok; Bhardwaj, A.; Choudhary, B. C.; Garg, R. B.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Nishu, N.; Ranjan, K.; Sharma, R.; Sharma, V.; Bhattacharya, S.; Chatterjee, K.; Dey, S.; Dutta, S.; Jain, Sa.; Majumdar, N.; Modak, A.; Mondal, K.; Mukherjee, S.; Mukhopadhyay, S.; Roy, A.; Roy, D.; Chowdhury, S. Roy; Sarkar, S.; Sharan, M.; Abdulsalam, A.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Banerjee, S.; Bhowmik, S.; Chatterjee, R. M.; Dewanjee, R. K.; Dugad, S.; Ganguly, S.; Ghosh, S.; Guchait, M.; Gurtu, A.; Kole, G.; Kumar, S.; Mahakud, B.; Maity, M.; Majumder, G.; Mazumdar, K.; Mitra, S.; Mohanty, G. B.; Parida, B.; Sarkar, T.; Sur, N.; Sutar, B.; Wickramage, N.; Chauhan, S.; Dube, S.; Kothekar, K.; Sharma, S.; Bakhshiansohi, H.; Behnamian, H.; Etesami, S. M.; Fahim, A.; Goldouzian, R.; Khakzad, M.; Najafabadi, M. Mohammadi; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Caputo, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Fiore, L.; Iaselli, G.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Silvestris, L.; Venditti, R.; Verwilligen, P.; Abbiendi, G.; Battilana, C.; Benvenuti, A. C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Brigliadori, L.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Travaglini, R.; Cappello, G.; Chiorboli, M.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Gonzi, S.; Gori, V.; Lenzi, P.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Tropiano, A.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Lo Vetere, M.; Monge, M. R.; Robutti, E.; Tosi, S.; Brianza, L.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Gerosa, R.; Ghezzi, A.; Govoni, P.; Malvezzi, S.; Manzoni, R. A.; Marzocchi, B.; Menasce, D.; Moroni, L.; Paganoni, M.; Pedrini, D.; Ragazzi, S.; Redaelli, N.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Esposito, M.; Fabozzi, F.; Iorio, A. O. M.; Lanza, G.; Lista, L.; Meola, S.; Merola, M.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Bacchetta, N.; Bellato, M.; Benato, L.; Bisello, D.; Boletti, A.; Carlin, R.; Checchia, P.; Dall'Osso, M.; Dosselli, U.; Gasparini, F.; Gasparini, U.; Gozzelino, A.; Lacaprara, S.; Margoni, M.; Meneguzzo, A. T.; Montecassiano, F.; Passaseo, M.; Pazzini, J.; Pegoraro, M.; Pozzobon, N.; Simonetto, F.; Torassa, E.; Tosi, M.; Vanini, S.; Ventura, S.; Zanetti, M.; Zotto, P.; Zucchetta, A.; Zumerle, G.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Biasini, M.; Bilei, G. M.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Mantovani, G.; Menichelli, M.; Saha, A.; Santocchia, A.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Bernardini, J.; Boccali, T.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Foà, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Serban, A. T.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; D'imperio, G.; Del Re, D.; Diemoz, M.; Gelli, S.; Jorda, C.; Longo, E.; Margaroli, F.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Traczyk, P.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bellan, R.; Biino, C.; Cartiglia, N.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Finco, L.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Solano, A.; Staiano, A.; Tamponi, U.; Belforte, S.; Candelise, V.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Gobbo, B.; La Licata, C.; Marone, M.; Schizzi, A.; Zanetti, A.; Kropivnitskaya, A.; Nam, S. K.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Kong, D. J.; Lee, S.; Oh, Y. D.; Sakharov, A.; Son, D. C.; Brochero Cifuentes, J. A.; Kim, H.; Kim, T. J.; Song, S.; Choi, S.; Go, Y.; Gyun, D.; Hong, B.; Jo, M.; Kim, H.; Kim, Y.; Lee, B.; Lee, K.; Lee, K. S.; Lee, S.; Park, S. K.; Roh, Y.; Yoo, H. D.; Choi, M.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Ryu, G.; Ryu, M. S.; Choi, Y.; Goh, J.; Kim, D.; Kwon, E.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Komaragiri, J. R.; Ali, M. A. B. Md; Mohamad Idris, F.; Abdullah, W. A. T. Wan; Yusli, M. N.; Casimiro Linares, E.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Hernandez-Almada, A.; Lopez-Fernandez, R.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Khan, W. A.; Khurshid, T.; Shoaib, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Romanowska-Rybinska, K.; Szleper, M.; Zalewski, P.; Brona, G.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Kierzkowski, K.; Konecki, M.; Krolikowski, J.; Misiura, M.; Oklinski, W.; Olszewski, M.; Pozniak, K.; Walczak, M.; Zabolotny, W.; Bargassa, P.; Silva, C. Beirão Da Cruz E.; Di Francesco, A.; Faccioli, P.; Ferreira Parracho, P. G.; Gallinaro, M.; Leonardo, N.; Lloret Iglesias, L.; Nguyen, F.; Rodrigues Antunes, J.; Seixas, J.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Vischia, P.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Konoplyanikov, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Moisenz, P.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Zarubin, A.; Golovtsov, V.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Vlasov, E.; Zhokin, A.; Bylinkin, A.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Mesyats, G.; Rusakov, S. V.; Baskakov, A.; Belyaev, A.; Boos, E.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Kaminskiy, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Myagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Krychkine, V.; Petrov, V.; Ryutin, R.; Sobol, A.; Tourtchanovitch, L.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Calvo, E.; Cerrada, M.; Chamizo Llatas, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Domínguez Vázquez, D.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Navarro De Martino, E.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Santaolalla, J.; Soares, M. S.; Albajar, C.; de Trocóniz, J. F.; Missiroli, M.; Moran, D.; Cuevas, J.; Fernandez Menendez, J.; Folgueras, S.; Gonzalez Caballero, I.; Palencia Cortezon, E.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Castiñeiras De Saa, J. R.; De Castro Manzano, P.; Duarte Campderros, J.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Marco, R.; Martinez Rivero, C.; Matorras, F.; Munoz Sanchez, F. J.; Piedra Gomez, J.; Rodrigo, T.; Rodríguez-Marrero, A. Y.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Auzinger, G.; Bachtis, M.; Baillon, P.; Ball, A. H.; Barney, D.; Benaglia, A.; Bendavid, J.; Benhabib, L.; Benitez, J. F.; Berruti, G. M.; Bloch, P.; Bocci, A.; Bonato, A.; Botta, C.; Breuker, H.; Camporesi, T.; Castello, R.; Cerminara, G.; D'Alfonso, M.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Guio, F.; De Roeck, A.; De Visscher, S.; Di Marco, E.; Dobson, M.; Dordevic, M.; Dorney, B.; du Pree, T.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Franzoni, G.; Funk, W.; Gigi, D.; Gill, K.; Giordano, D.; Girone, M.; Glege, F.; Guida, R.; Gundacker, S.; Guthoff, M.; Hammer, J.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Kirschenmann, H.; Kortelainen, M. J.; Kousouris, K.; Krajczar, K.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Magini, N.; Malgeri, L.; Mannelli, M.; Martelli, A.; Masetti, L.; Meijers, F.; Mersi, S.; Meschi, E.; Moortgat, F.; Morovic, S.; Mulders, M.; Nemallapudi, M. V.; Neugebauer, H.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Piparo, D.; Racz, A.; Rolandi, G.; Rovere, M.; Ruan, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Seidel, M.; Sharma, A.; Silva, P.; Simon, M.; Sphicas, P.; Steggemann, J.; Stieger, B.; Stoye, M.; Takahashi, Y.; Treille, D.; Triossi, A.; Tsirou, A.; Veres, G. I.; Wardle, N.; Wöhri, H. K.; Zagozdzinska, A.; Zeuner, W. D.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Renker, D.; Rohe, T.; Bachmair, F.; Bäni, L.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegà, M.; Eller, P.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lustermann, W.; Mangano, B.; Marionneau, M.; Martinez Ruiz del Arbol, P.; Masciovecchio, M.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrozzi, L.; Quittnat, M.; Rossini, M.; Starodumov, A.; Takahashi, M.; Tavolaro, V. R.; Theofilatos, K.; Wallny, R.; Aarrestad, T. K.; Amsler, C.; Caminada, L.; Canelli, M. F.; Chiochia, V.; De Cosa, A.; Galloni, C.; Hinzmann, A.; Hreus, T.; Kilminster, B.; Lange, C.; Ngadiuba, J.; Pinna, D.; Robmann, P.; Ronga, F. J.; Salerno, D.; Yang, Y.; Cardaci, M.; Chen, K. H.; Doan, T. H.; Jain, Sh.; Khurana, R.; Konyushikhin, M.; Kuo, C. M.; Lin, W.; Lu, Y. J.; Yu, S. S.; Kumar, Arun; Bartek, R.; Chang, P.; Chang, Y. H.; Chang, Y. W.; Chao, Y.; Chen, K. F.; Chen, P. H.; Dietz, C.; Fiori, F.; Grundler, U.; Hou, W.-S.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Miñano Moya, M.; Petrakou, E.; Tsai, J. f.; Tzeng, Y. M.; Asavapibhop, B.; Kovitanggoon, K.; Singh, G.; Srimanobhas, N.; Suwonjandee, N.; Adiguzel, A.; Bakirci, M. N.; Demiroglu, Z. S.; Dozen, C.; Eskut, E.; Girgis, S.; Gokbulut, G.; Guler, Y.; Gurpinar, E.; Hos, I.; Kangal, E. E.; Onengut, G.; Ozdemir, K.; Polatoz, A.; Sunar Cerci, D.; Tali, B.; Topakli, H.; Vergili, M.; Zorbilmez, C.; Akin, I. V.; Bilin, B.; Bilmis, S.; Isildak, B.; Karapinar, G.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Yetkin, E. A.; Yetkin, T.; Cakir, A.; Cankocak, K.; Sen, S.; Vardarlı, F. I.; Grynyov, B.; Levchuk, L.; Sorokin, P.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Clement, E.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Meng, Z.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Senkin, S.; Smith, D.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Womersley, W. J.; Worm, S. D.; Baber, M.; Bainbridge, R.; Buchmuller, O.; Bundock, A.; Burton, D.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Cripps, N.; Dauncey, P.; Davies, G.; De Wit, A.; Della Negra, M.; Dunne, P.; Elwood, A.; Ferguson, W.; Fulcher, J.; Futyan, D.; Hall, G.; Iles, G.; Kenzie, M.; Lane, R.; Lucas, R.; Lyons, L.; Magnan, A.-M.; Malik, S.; Nash, J.; Nikitenko, A.; Pela, J.; Pesaresi, M.; Petridis, K.; Raymond, D. M.; Richards, A.; Rose, A.; Seez, C.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Leggat, D.; Leslie, D.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Charaf, O.; Cooper, S. I.; Henderson, C.; Rumerio, P.; Arcaro, D.; Avetisyan, A.; Bose, T.; Fantasia, C.; Gastler, D.; Lawson, P.; Rankin, D.; Richardson, C.; Rohlf, J.; St. John, J.; Sulak, L.; Zou, D.; Alimena, J.; Berry, E.; Bhattacharya, S.; Cutts, D.; Dhingra, N.; Ferapontov, A.; Garabedian, A.; Hakala, J.; Heintz, U.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Piperov, S.; Sagir, S.; Syarif, R.; Breedon, R.; Breto, G.; Calderon De La Barca Sanchez, M.; Chauhan, S.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Gardner, M.; Ko, W.; Lander, R.; Mulhearn, M.; Pellett, D.; Pilot, J.; Ricci-Tam, F.; Shalhout, S.; Smith, J.; Squires, M.; Stolp, D.; Tripathi, M.; Wilbur, S.; Yohay, R.; Cousins, R.; Everaerts, P.; Farrell, C.; Hauser, J.; Ignatenko, M.; Saltzberg, D.; Takasugi, E.; Valuev, V.; Weber, M.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Hanson, G.; Heilman, J.; Ivova PANEVA, M.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Luthra, A.; Malberti, M.; Olmedo Negrete, M.; Shrinivas, A.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cerati, G. B.; Cittolin, S.; D'Agnolo, R. T.; Derdzinski, M.; Holzner, A.; Kelley, R.; Klein, D.; Letts, J.; Macneill, I.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Welke, C.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Flowers, K.; Sevilla, M. Franco; Geffert, P.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Incandela, J.; Mccoll, N.; Mullin, S. D.; Richman, J.; Stuart, D.; Suarez, I.; West, C.; Yoo, J.; Anderson, D.; Apresyan, A.; Bornheim, A.; Bunn, J.; Chen, Y.; Duarte, J.; Mott, A.; Newman, H. B.; Pena, C.; Pierini, M.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhu, R. Y.; Andrews, M. B.; Azzolini, V.; Calamba, A.; Carlson, B.; Ferguson, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Cumalat, J. P.; Ford, W. T.; Gaz, A.; Jensen, F.; Johnson, A.; Krohn, M.; Mulholland, T.; Nauenberg, U.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chatterjee, A.; Chaves, J.; Chu, J.; Dittmer, S.; Eggert, N.; Mirman, N.; Kaufman, G. Nicolas; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Soffi, L.; Sun, W.; Tan, S. M.; Teo, W. D.; Thom, J.; Thompson, J.; Tucker, J.; Weng, Y.; Wittich, P.; Abdullin, S.; Albrow, M.; Anderson, J.; Apollinari, G.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Cheung, H. W. K.; Chlebana, F.; Cihangir, S.; Elvira, V. D.; Fisk, I.; Freeman, J.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Hanlon, J.; Hare, D.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Jung, A. W.; Klima, B.; Kreis, B.; Kwan, S.; Lammel, S.; Linacre, J.; Lincoln, D.; Lipton, R.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Marraffino, J. M.; Martinez Outschoorn, V. I.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mishra, K.; Mrenna, S.; Nahn, S.; Newman-Holmes, C.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Weber, H. A.; Whitbeck, A.; Yang, F.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Carnes, A.; Carver, M.; Curry, D.; Das, S.; Di Giovanni, G. P.; Field, R. D.; Furic, I. K.; Gleyzer, S. V.; Hugon, J.; Konigsberg, J.; Korytov, A.; Low, J. F.; Ma, P.; Matchev, K.; Mei, H.; Milenovic, P.; Mitselmakher, G.; Rank, D.; Rossin, R.; Shchutska, L.; Snowball, M.; Sperka, D.; Terentyev, N.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Hewamanage, S.; Linn, S.; Markowitz, P.; Martinez, G.; Rodriguez, J. L.; Ackert, A.; Adams, J. R.; Adams, T.; Askew, A.; Bochenek, J.; Diamond, B.; Haas, J.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Khatiwada, A.; Prosper, H.; Weinberg, M.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Kalakhety, H.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Bucinskaite, I.; Cavanaugh, R.; Evdokimov, O.; Gauthier, L.; Gerber, C. E.; Hofman, D. J.; Kurt, P.; O'Brien, C.; Sandoval Gonzalez, I. D.; Silkworth, C.; Turner, P.; Varelas, N.; Wu, Z.; Zakaria, M.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Anderson, I.; Barnett, B. A.; Blumenfeld, B.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Martin, C.; Osherson, M.; Roskes, J.; Sady, A.; Sarica, U.; Swartz, M.; Xiao, M.; Xin, Y.; You, C.; Baringer, P.; Bean, A.; Benelli, G.; Bruner, C.; Kenny, R. P., III; Majumder, D.; Malek, M.; Murray, M.; Sanders, S.; Stringer, R.; Wang, Q.; Ivanov, A.; Kaadze, K.; Khalil, S.; Makouski, M.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Lange, D.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Gomez, J. A.; Hadley, N. J.; Jabeen, S.; Kellogg, R. G.; Kolberg, T.; Kunkle, J.; Lu, Y.; Mignerey, A. C.; Shin, Y. H.; Skuja, A.; Tonjes, M. B.; Tonwar, S. C.; Apyan, A.; Barbieri, R.; Baty, A.; Bierwagen, K.; Brandt, S.; Busza, W.; Cali, I. A.; Demiragli, Z.; Di Matteo, L.; Gomez Ceballos, G.; Goncharov, M.; Gulhan, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Ralph, D.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Sumorok, K.; Varma, M.; Velicanu, D.; Veverka, J.; Wang, J.; Wang, T. W.; Wyslouch, B.; Yang, M.; Zhukova, V.; Dahmes, B.; Evans, A.; Finkel, A.; Gude, A.; Hansen, P.; Kalafut, S.; Kao, S. C.; Klapoetke, K.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Tambe, N.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bloom, K.; Bose, S.; Claes, D. R.; Dominguez, A.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Keller, J.; Knowlton, D.; Kravchenko, I.; Meier, F.; Monroy, J.; Ratnikov, F.; Siado, J. E.; Snow, G. R.; Alyari, M.; Dolen, J.; George, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Kaisen, J.; Kharchilava, A.; Kumar, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Baumgartel, D.; Chasco, M.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira De Lima, R.; Trocino, D.; Wang, R.-J.; Wood, D.; Zhang, J.; Hahn, K. A.; Kubik, A.; Mucia, N.; Odell, N.; Pollack, B.; Pozdnyakov, A.; Schmitt, M.; Stoynev, S.; Sung, K.; Trovato, M.; Velasco, M.; Brinkerhoff, A.; Dev, N.; Hildreth, M.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Lynch, S.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Pearson, T.; Planer, M.; Reinsvold, A.; Ruchti, R.; Smith, G.; Taroni, S.; Valls, N.; Wayne, M.; Wolf, M.; Woodard, A.; Antonelli, L.; Brinson, J.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Hart, A.; Hill, C.; Hughes, R.; Ji, W.; Kotov, K.; Ling, T. Y.; Liu, B.; Luo, W.; Puigh, D.; Rodenburg, M.; Winer, B. L.; Wulsin, H. W.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Koay, S. A.; Lujan, P.; Marlow, D.; Medvedeva, T.; Mooney, M.; Olsen, J.; Palmer, C.; Piroué, P.; Saka, H.; Stickland, D.; Tully, C.; Zuranski, A.; Malik, S.; Barnes, V. E.; Benedetti, D.; Bortoletto, D.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, K.; Miller, D. H.; Neumeister, N.; Radburn-Smith, B. C.; Shi, X.; Shipsey, I.; Silvers, D.; Sun, J.; Svyatkovskiy, A.; Wang, F.; Xie, W.; Xu, L.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Redjimi, R.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Betchart, B.; Bodek, A.; de Barbaro, P.; Demina, R.; Eshaq, Y.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Harel, A.; Hindrichs, O.; Khukhunaishvili, A.; Petrillo, G.; Tan, P.; Verzetti, M.; Arora, S.; Barker, A.; Chou, J. P.; Contreras-Campana, C.; Contreras-Campana, E.; Duggan, D.; Ferencek, D.; Gershtein, Y.; Gray, R.; Halkiadakis, E.; Hidas, D.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Lath, A.; Nash, K.; Panwalkar, S.; Park, M.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Foerster, M.; Riley, G.; Rose, K.; Spanier, S.; York, A.; Bouhali, O.; Castaneda Hernandez, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Kamon, T.; Krutelyov, V.; Mueller, R.; Osipenkov, I.; Pakhotin, Y.; Patel, R.; Perloff, A.; Rose, A.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Cowden, C.; Damgov, J.; Dragoiu, C.; Dudero, P. R.; Faulkner, J.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Undleeb, S.; Volobouev, I.; Appelt, E.; Delannoy, A. G.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Mao, Y.; Melo, A.; Ni, H.; Sheldon, P.; Snook, B.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Cox, B.; Francis, B.; Goodell, J.; Hirosky, R.; Ledovskoy, A.; Li, H.; Lin, C.; Neu, C.; Sinthuprasith, T.; Sun, X.; Wang, Y.; Wolfe, E.; Wood, J.; Xia, F.; Clarke, C.; Harr, R.; Karchin, P. E.; Kottachchi Kankanamge Don, C.; Lamichhane, P.; Sturdy, J.; Belknap, D. A.; Carlsmith, D.; Cepeda, M.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Hall-Wilton, R.; Herndon, M.; Hervé, A.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Mohapatra, A.; Ojalvo, I.; Perry, T.; Pierro, G. A.; Polese, G.; Ruggles, T.; Sarangi, T.; Savin, A.; Sharma, A.; Smith, N.; Smith, W. H.; Taylor, D.; Woods, N.
2017-01-01
This paper describes the CMS trigger system and its performance during Run 1 of the LHC. The trigger system consists of two levels designed to select events of potential physics interest from a GHz (MHz) interaction rate of proton-proton (heavy ion) collisions. The first level of the trigger is implemented in hardware, and selects events containing detector signals consistent with an electron, photon, muon, τ lepton, jet, or missing transverse energy. A programmable menu of up to 128 object-based algorithms is used to select events for subsequent processing. The trigger thresholds are adjusted to the LHC instantaneous luminosity during data taking in order to restrict the output rate to 100 kHz, the upper limit imposed by the CMS readout electronics. The second level, implemented in software, further refines the purity of the output stream, selecting an average rate of 400 Hz for offline event storage. The objectives, strategy and performance of the trigger system during the LHC Run 1 are described.
Khachatryan, Vardan
2017-01-24
This paper describes the CMS trigger system and its performance during Run 1 of the LHC. The trigger system consists of two levels designed to select events of potential physics interest from a GHz (MHz) interaction rate of proton-proton (heavy ion) collisions. The first level of the trigger is implemented in hardware, and selects events containing detector signals consistent with an electron, photon, muon, tau lepton, jet, or missing transverse energy. A programmable menu of up to 128 object-based algorithms is used to select events for subsequent processing. The trigger thresholds are adjusted to the LHC instantaneous luminosity during datamore » taking in order to restrict the output rate to 100 kHz, the upper limit imposed by the CMS readout electronics. The second level, implemented in software, further refines the purity of the output stream, selecting an average rate of 400 Hz for offline event storage. The objectives, strategy and performance of the trigger system during the LHC Run 1 are described.« less
CMS distributed data analysis with CRAB3
NASA Astrophysics Data System (ADS)
Mascheroni, M.; Balcas, J.; Belforte, S.; Bockelman, B. P.; Hernandez, J. M.; Ciangottini, D.; Konstantinov, P. B.; Silva, J. M. D.; Ali, M. A. B. M.; Melo, A. M.; Riahi, H.; Tanasijczuk, A. J.; Yusli, M. N. B.; Wolf, M.; Woodard, A. E.; Vaandering, E.
2015-12-01
The CMS Remote Analysis Builder (CRAB) is a distributed workflow management tool which facilitates analysis tasks by isolating users from the technical details of the Grid infrastructure. Throughout LHC Run 1, CRAB has been successfully employed by an average of 350 distinct users each week executing about 200,000 jobs per day. CRAB has been significantly upgraded in order to face the new challenges posed by LHC Run 2. Components of the new system include 1) a lightweight client, 2) a central primary server which communicates with the clients through a REST interface, 3) secondary servers which manage user analysis tasks and submit jobs to the CMS resource provisioning system, and 4) a central service to asynchronously move user data from temporary storage in the execution site to the desired storage location. The new system improves the robustness, scalability and sustainability of the service. Here we provide an overview of the new system, operation, and user support, report on its current status, and identify lessons learned from the commissioning phase and production roll-out.
Terahertz imaging with compressive sensing
NASA Astrophysics Data System (ADS)
Chan, Wai Lam
Most existing terahertz imaging systems are generally limited by slow image acquisition due to mechanical raster scanning. Other systems using focal plane detector arrays can acquire images in real time, but are either too costly or limited by low sensitivity in the terahertz frequency range. To design faster and more cost-effective terahertz imaging systems, the first part of this thesis proposes two new terahertz imaging schemes based on compressive sensing (CS). Both schemes can acquire amplitude and phase-contrast images efficiently with a single-pixel detector, thanks to the powerful CS algorithms which enable the reconstruction of N-by- N pixel images with much fewer than N2 measurements. The first CS Fourier imaging approach successfully reconstructs a 64x64 image of an object with pixel size 1.4 mm using a randomly chosen subset of the 4096 pixels which defines the image in the Fourier plane. Only about 12% of the pixels are required for reassembling the image of a selected object, equivalent to a 2/3 reduction in acquisition time. The second approach is single-pixel CS imaging, which uses a series of random masks for acquisition. Besides speeding up acquisition with a reduced number of measurements, the single-pixel system can further cut down acquisition time by electrical or optical spatial modulation of random patterns. In order to switch between random patterns at high speed in the single-pixel imaging system, the second part of this thesis implements a multi-pixel electrical spatial modulator for terahertz beams using active terahertz metamaterials. The first generation of this device consists of a 4x4 pixel array, where each pixel is an array of sub-wavelength-sized split-ring resonator elements fabricated on a semiconductor substrate, and is independently controlled by applying an external voltage. The spatial modulator has a uniform modulation depth of around 40 percent across all pixels, and negligible crosstalk, at the resonant frequency. The second-generation spatial terahertz modulator, also based on metamaterials with a higher resolution (32x32), is under development. A FPGA-based circuit is designed to control the large number of modulator pixels. Once fully implemented, this second-generation device will enable fast terahertz imaging with both pulsed and continuous-wave terahertz sources.
1988-05-19
System for the Ada Language System, Version 1.1.0, 1.% International Business Machines Corporation, Wright-Patterson AFB. IBM 4381 under VM/SP CMS...THIS PAGE (When Data Enre’ed) AVF Control Number: AVF-VSR-82.1087 87-03-10-TEL ! Ada® COMPILER VALIDATION SUMMARY REPORT: International Business Machines...Organization (AVO). On-site testing was conducted from !8 May 1987 through 19 May 1987 at International Business Machines -orporation, San Diego CA. 1.2
NASA Astrophysics Data System (ADS)
Kuehl, C. Stephen
1996-06-01
Video signal system performance can be compromised in a military aircraft cockpit management system (CMS) with the tailoring of vintage Electronics Industries Association (EIA) RS170 and RS343A video interface standards. Video analog interfaces degrade when induced system noise is present. Further signal degradation has been traditionally associated with signal data conversions between avionics sensor outputs and the cockpit display system. If the CMS engineering process is not carefully applied during the avionics video and computing architecture development, extensive and costly redesign will occur when visual sensor technology upgrades are incorporated. Close monitoring and technical involvement in video standards groups provides the knowledge-base necessary for avionic systems engineering organizations to architect adaptable and extendible cockpit management systems. With the Federal Communications Commission (FCC) in the process of adopting the Digital HDTV Grand Alliance System standard proposed by the Advanced Television Systems Committee (ATSC), the entertainment and telecommunications industries are adopting and supporting the emergence of new serial/parallel digital video interfaces and data compression standards that will drastically alter present NTSC-M video processing architectures. The re-engineering of the U.S. Broadcasting system must initially preserve the electronic equipment wiring networks within broadcast facilities to make the transition to HDTV affordable. International committee activities in technical forums like ITU-R (former CCIR), ANSI/SMPTE, IEEE, and ISO/IEC are establishing global consensus on video signal parameterizations that support a smooth transition from existing analog based broadcasting facilities to fully digital computerized systems. An opportunity exists for implementing these new video interface standards over existing video coax/triax cabling in military aircraft cockpit management systems. Reductions in signal conversion processing steps, major improvement in video noise reduction, and an added capability to pass audio/embedded digital data within the digital video signal stream are the significant performance increases associated with the incorporation of digital video interface standards. By analyzing the historical progression of military CMS developments, establishing a systems engineering process for CMS design, tracing the commercial evolution of video signal standardization, adopting commercial video signal terminology/definitions, and comparing/contrasting CMS architecture modifications using digital video interfaces; this paper provides a technical explanation on how a systems engineering process approach to video interface standardization can result in extendible and affordable cockpit management systems.
First Experiences with CMS Data Storage on the GEMSS System at the INFN-CNAF Tier-1
NASA Astrophysics Data System (ADS)
Andreotti, D.; Bonacorsi, D.; Cavalli, A.; Pra, S. Dal; Dell'Agnello, L.; Forti, Alberto; Grandi, C.; Gregori, D.; Gioi, L. Li; Martelli, B.; Prosperini, A.; Ricci, P. P.; Ronchieri, Elisabetta; Sapunenko, V.; Sartirana, A.; Vagnoni, V.; Zappi, Riccardo
A brand new Mass Storage System solution called "Grid-Enabled Mass Storage System" (GEMSS) -based on the Storage Resource Manager (StoRM) developed by INFN, on the General Parallel File System by IBM and on the Tivoli Storage Manager by IBM -has been tested and deployed at the INFNCNAF Tier-1 Computing Centre in Italy. After a successful stress test phase, the solution is now being used in production for the data custodiality of the CMS experiment at CNAF. All data previously recorded on the CASTOR system have been transferred to GEMSS. As final validation of the GEMSS system, some of the computing tests done in the context of the WLCG "Scale Test for the Experiment Program" (STEP'09) challenge were repeated in September-October 2009 and compared with the results previously obtained with CASTOR in June 2009. In this paper, the GEMSS system basics, the stress test activity and the deployment phase -as well as the reliability and performance of the system -are overviewed. The experiences in the use of GEMSS at CNAF in preparing for the first months of data taking of the CMS experiment at the Large Hadron Collider are also presented.
2010-01-01
Background A growing body of evidence suggests that effective blood pressure reduction may inhibit the progression of microvascular damage in patients with essential arterial hypertension. However, the potential influence of anti-hypertensive drugs on ocular circulation has not been studied sufficiently. Purpose The aim of our study was to evaluate the effects of anti-hypertensive therapy on blood flow in the central retinal artery in patients with systemic arterial hypertension. Material and methods Twenty patients with essential arterial hypertension, aged 32–46 years, were examined with Doppler ultrasonography (10 MHz ultrasound probe). Blood flow velocities, pulsatility, and vascular resistance were determined before and 3 hours after systemic application of either bisoprolol 5 mg or cilazapril 2.5 mg. Results Administered bisoprolol significantly decreased maximum (9.8 ± 0.5 cm/s versus 8.5 ± 0.6 cm/s; P < 0.05) and minimum (2.75 ± 0.19 cm/s versus 1.75 ± 0.27 cm/s; P < 0.02) velocity, increased the Pourcellot's index (0.71 to 0.79; P < 0.05) in central retinal artery. There were no statistically significant changes in central retinal artery blood flow after administration of cilazapril. Conclusion Systemic application of beta-blockers may unfavourably disturb the ocular blood flow. PMID:20858158
New operator assistance features in the CMS Run Control System
NASA Astrophysics Data System (ADS)
Andre, J.-M.; Behrens, U.; Branson, J.; Brummer, P.; Chaze, O.; Cittolin, S.; Contescu, C.; Craigs, B. G.; Darlea, G.-L.; Deldicque, C.; Demiragli, Z.; Dobson, M.; Doualot, N.; Erhan, S.; Fulcher, J. R.; Gigi, D.; Gładki, M.; Glege, F.; Gomez-Ceballos, G.; Hegeman, J.; Holzner, A.; Janulis, M.; Jimenez-Estupiñán, R.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; Morovic, S.; O'Dell, V.; Orsini, L.; Paus, C.; Petrova, P.; Pieri, M.; Racz, A.; Reis, T.; Sakulin, H.; Schwick, C.; Simelevicius, D.; Vougioukas, M.; Zejdl, P.
2017-10-01
During Run-1 of the LHC, many operational procedures have been automated in the run control system of the Compact Muon Solenoid (CMS) experiment. When detector high voltages are ramped up or down or upon certain beam mode changes of the LHC, the DAQ system is automatically partially reconfigured with new parameters. Certain types of errors such as errors caused by single-event upsets may trigger an automatic recovery procedure. Furthermore, the top-level control node continuously performs cross-checks to detect sub-system actions becoming necessary because of changes in configuration keys, changes in the set of included front-end drivers or because of potential clock instabilities. The operator is guided to perform the necessary actions through graphical indicators displayed next to the relevant command buttons in the user interface. Through these indicators, consistent configuration of CMS is ensured. However, manually following the indicators can still be inefficient at times. A new assistant to the operator has therefore been developed that can automatically perform all the necessary actions in a streamlined order. If additional problems arise, the new assistant tries to automatically recover from these. With the new assistant, a run can be started from any state of the sub-systems with a single click. An ongoing run may be recovered with a single click, once the appropriate recovery action has been selected. We review the automation features of CMS Run Control and discuss the new assistant in detail including first operational experience.
New Operator Assistance Features in the CMS Run Control System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andre, J.M.; et al.
During Run-1 of the LHC, many operational procedures have been automated in the run control system of the Compact Muon Solenoid (CMS) experiment. When detector high voltages are ramped up or down or upon certain beam mode changes of the LHC, the DAQ system is automatically partially reconfigured with new parameters. Certain types of errors such as errors caused by single-event upsets may trigger an automatic recovery procedure. Furthermore, the top-level control node continuously performs cross-checks to detect sub-system actions becoming necessary because of changes in configuration keys, changes in the set of included front-end drivers or because of potentialmore » clock instabilities. The operator is guided to perform the necessary actions through graphical indicators displayed next to the relevant command buttons in the user interface. Through these indicators, consistent configuration of CMS is ensured. However, manually following the indicators can still be inefficient at times. A new assistant to the operator has therefore been developed that can automatically perform all the necessary actions in a streamlined order. If additional problems arise, the new assistant tries to automatically recover from these. With the new assistant, a run can be started from any state of the sub-systems with a single click. An ongoing run may be recovered with a single click, once the appropriate recovery action has been selected. We review the automation features of CMS Run Control and discuss the new assistant in detail including first operational experience.« less
Iorga, Bogdan; Schwanke, Kristin; Weber, Natalie; Wendland, Meike; Greten, Stephan; Piep, Birgit; dos Remedios, Cristobal G.; Martin, Ulrich; Zweigerdt, Robert; Kraft, Theresia; Brenner, Bernhard
2018-01-01
Characterizing the contractile function of human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) is key for advancing their utility for cellular disease models, promoting cell based heart repair, or developing novel pharmacological interventions targeting cardiac diseases. The aim of the present study was to understand whether steady-state and kinetic force parameters of β-myosin heavy chain (βMyHC) isoform-expressing myofibrils within human embryonic stem cell-derived cardiomyocytes (hESC-CMs) differentiated in vitro resemble those of human ventricular myofibrils (hvMFs) isolated from adult donor hearts. Contractile parameters were determined using the same micromechanical method and experimental conditions for both types of myofibrils. We identified isoforms and phosphorylation of main sarcomeric proteins involved in the modulation of force generation of both, chemically demembranated hESC-CMs (d-hESC-CMs) and hvMFs. Our results indicate that at saturating Ca2+ concentration, both human-derived contractile systems developed forces with similar rate constants (0.66 and 0.68 s−1), reaching maximum isometric force that was significantly smaller for d-hESC-CMs (42 kPa) than for hvMFs (94 kPa). At submaximal Ca2+-activation, where intact cardiomyocytes normally operate, contractile parameters of d-hESC-CMs and hvMFs exhibited differences. Ca2+ sensitivity of force was higher for d-hESC-CMs (pCa50 = 6.04) than for hvMFs (pCa50 = 5.80). At half-maximum activation, the rate constant for force redevelopment was significantly faster for d-hESC-CMs (0.51 s−1) than for hvMFs (0.28 s−1). During myofibril relaxation, kinetics of the slow force decay phase were significantly faster for d-hESC-CMs (0.26 s−1) than for hvMFs (0.21 s−1), while kinetics of the fast force decay were similar and ~20x faster. Protein analysis revealed that hESC-CMs had essentially no cardiac troponin-I, and partially non-ventricular isoforms of some other sarcomeric proteins, explaining the functional discrepancies. The sarcomeric protein isoform pattern of hESC-CMs had features of human cardiomyocytes at an early developmental stage. The study indicates that morphological and ultrastructural maturation of βMyHC isoform-expressing hESC-CMs is not necessarily accompanied by ventricular-like expression of all sarcomeric proteins. Our data suggest that hPSC-CMs could provide useful tools for investigating inherited cardiac diseases affecting contractile function during early developmental stages. PMID:29403388
Wafer-scale pixelated detector system
Fahim, Farah; Deptuch, Grzegorz; Zimmerman, Tom
2017-10-17
A large area, gapless, detection system comprises at least one sensor; an interposer operably connected to the at least one sensor; and at least one application specific integrated circuit operably connected to the sensor via the interposer wherein the detection system provides high dynamic range while maintaining small pixel area and low power dissipation. Thereby the invention provides methods and systems for a wafer-scale gapless and seamless detector systems with small pixels, which have both high dynamic range and low power dissipation.
NASA Astrophysics Data System (ADS)
MacMahon, Heber; Vyborny, Carl; Powell, Gregory; Doi, Kunio; Metz, Charles E.
1984-08-01
In digital radiography the pixel size used determines the potential spatial resolution of the system. The need for spatial resolution varies depending on the subject matter imaged. In many areas, including the chest, the minimum spatial resolution requirements have not been determined. Sarcoidosis is a disease which frequently causes subtle interstitial infiltrates in the lungs. As the initial step in an investigation designed to determine the minimum pixel size required in digital chest radiographic systems, we have studied 1 mm pixel digitized images on patients with early pulmonary sarcoidosis. The results of this preliminary study suggest that neither mild interstitial pulmonary infiltrates nor other abnormalities such as pneumothoraces may be detected reliably with 1 mm pixel digital images.
Computational imaging with a single-pixel detector and a consumer video projector
NASA Astrophysics Data System (ADS)
Sych, D.; Aksenov, M.
2018-02-01
Single-pixel imaging is a novel rapidly developing imaging technique that employs spatially structured illumination and a single-pixel detector. In this work, we experimentally demonstrate a fully operating modular single-pixel imaging system. Light patterns in our setup are created with help of a computer-controlled digital micromirror device from a consumer video projector. We investigate how different working modes and settings of the projector affect the quality of reconstructed images. We develop several image reconstruction algorithms and compare their performance for real imaging. Also, we discuss the potential use of the single-pixel imaging system for quantum applications.
The CMS tracker control system
NASA Astrophysics Data System (ADS)
Dierlamm, A.; Dirkes, G. H.; Fahrer, M.; Frey, M.; Hartmann, F.; Masetti, L.; Militaru, O.; Shah, S. Y.; Stringer, R.; Tsirou, A.
2008-07-01
The Tracker Control System (TCS) is a distributed control software to operate about 2000 power supplies for the silicon modules of the CMS Tracker and monitor its environmental sensors. TCS must thus be able to handle about 104 power supply parameters, about 103 environmental probes from the Programmable Logic Controllers of the Tracker Safety System (TSS), about 105 parameters read via DAQ from the DCUs in all front end hybrids and from CCUs in all control groups. TCS is built on top of an industrial SCADA program (PVSS) extended with a framework developed at CERN (JCOP) and used by all LHC experiments. The logical partitioning of the detector is reflected in the hierarchical structure of the TCS, where commands move down to the individual hardware devices, while states are reported up to the root which is interfaced to the broader CMS control system. The system computes and continuously monitors the mean and maximum values of critical parameters and updates the percentage of currently operating hardware. Automatic procedures switch off selected parts of the detector using detailed granularity and avoiding widespread TSS intervention.
LibGuides: A CMS for Busy Librarians
ERIC Educational Resources Information Center
Verbit, Daniel; Kline, Vickie L.
2011-01-01
One of the toughest challenges in an academic library systems office is how to manage and present the extensive selection of electronic resources from a variety of vendors. At York College of Pennsylvania, the authors participated in an admissions-driven web revision cycle and used a campus-provided CMS for 8 years. During this time, they tried…
Enabling global collaborations through policy engagement and CMS applications
NASA Astrophysics Data System (ADS)
Escobar, V. M.; Sepulveda Carlo, E.; Delgado Arias, S.
2015-12-01
Different spatial scales prompt different discussions among carbon data stakeholders. NASA's Carbon Monitoring System (CMS) initiative has enabled collaboration opportunities with stakeholders whose data needs and requirements are unique to the spatial scope of their work: from county to the international scale. At the very local level, the Sonoma County Agricultural Preservation and Open Space District leverages CMS high-resolution biomass estimates to develop a Monitoring, Reporting, and Verification (MRV) system in support of the District's 10-year land stewardship plan and the California's Global Warming Solutions Act (AB32). On the eastern coast, at the state level, the Maryland Department of Natural Resources utilizes the same high-resolution biomass estimates on a larger scale to better strategize in achieving the goal of 40% canopy cover statewide by 2020. At a regional scale that encompasses the three states of Maryland, Delaware, and Pennsylvania, LiDAR data collection of the Chesapeake Bay watershed dominate the stakeholder discussions. By collaborating with the U.S. Geological Survey's 3-D Elevation Program (3DEP), high-resolution LiDAR data will fill critical data gaps to help implement watershed protection strategies such as increasing riparian forest buffers to reduce runoff. Outside of the U.S., the World Resources Institute seeks to harness CMS reforestation products and technical expertise in addressing land restoration priorities specific to each Latin American country. CMS applications efforts expand beyond forest carbon examples discussed above to include carbon markets, ocean acidification, national greenhouse gas inventory, and wetlands. The broad array of case studies and lessons learned through CMS Applications in scaling carbon science for policy development at different spatial scales is providing unique opportunities that leverage science through policy needs.
Bilginer, Burcak; Narin, Firat; Hanalioglu, Sahin; Oguz, Kader Karlı; Soylemezoglu, Figen; Akalan, Nejat
2014-08-01
Cavernous malformations (CMs) of the central nervous system (CNS) are angiographically occult vascular lesions that affect approximately 0.5 % of the general population, and one quarter of all CMs occurs in children. We retrospectively analyzed demographic, clinical, radiological, management, and follow-up data of 36 pediatric patients with CMs from a single institution. The mean age of the children at first presentation and at operation was 8.7 and 9.6 years, respectively. However, a bimodal age distribution was found with peak under 4 years and above 12 years. Seizure was the most common single presenting symptom (38.9 %), and 61.1 % of patients had at least one seizure before the admission. Focal neurological deficits (410.7 %), intracranial hypertension (27.8 %), and headache (2.8 %) were the other manifestations. Acute/subacute hemorrhage was evident at presentation in 63.9 %. The patients under 6 years of age were found to have significantly more giant cavernomas (69 vs 20 %; p = 0.011), and more overt hemorrhages (81 vs 47 %; p = 0.065) at diagnosis than those patients above 12 years. Surgery was performed in 31 patients (32 CMs), with 26 total and 6 incomplete resections. Mean follow-up duration was 6.9 ± 4.1 years. Of all patients, 63.8 % had excellent and 30.5 % had good clinical outcomes, and also 90.9 % of the epileptic patients were seizure-free (Engel Class I) at the last follow-up. Younger children tend to harbor larger CMs and present with hemorrhage more frequently than older ones. Microsurgical resection should be the treatment of choice in symptomatic and accessible CMs.
Saito, Yukihiro; Nakamura, Kazufumi; Yoshida, Masashi; Sugiyama, Hiroki; Takano, Makoto; Nagase, Satoshi; Morita, Hiroshi; Kusano, Kengo F; Ito, Hiroshi
2018-05-30
A biological pacemaker is expected to solve the persisting problems of an artificial cardiac pacemaker including short battery life, lead breaks, infection, and electromagnetic interference. We previously reported HCN4 overexpression enhances pacemaking ability of mouse embryonic stem cell-derived cardiomyocytes (mESC-CMs) in vitro. However, the effect of these cells on bradycardia in vivo has remained unclear. Therefore, we transplanted HCN4-overexpressing mESC-CMs into bradycardia model animals and investigated whether they could function as a biological pacemaker. The rabbit Hcn4 gene was transfected into mouse embryonic stem cells and induced HCN4-overexpressing mESC-CMs. Non-cardiomyocytes were removed under serum/glucose-free and lactate-supplemented conditions. Cardiac balls containing 5 × 10 3 mESC-CMs were made by using the hanging drop method. One hundred cardiac balls were injected into the left ventricular free wall of complete atrioventricular block (CAVB) model rats. Heart beats were evaluated using an implantable telemetry system 7 to 30 days after cell transplantation. The result showed that ectopic ventricular beats that were faster than the intrinsic escape rhythm were often observed in CAVB model rats transplanted with HCN4-overexpressing mESC-CMs. On the other hand, the rats transplanted with non-overexpressing mESC-CMs showed sporadic single premature ventricular contraction but not sustained ectopic ventricular rhythms. These results indicated that HCN4-overexpressing mESC-CMs produce rapid ectopic ventricular rhythms as a biological pacemaker.
Saeidpour, S; Lohan, S B; Anske, M; Unbehauen, M; Fleige, E; Haag, R; Meinke, M C; Bittl, R; Teutloff, C
2017-07-01
The skin and especially the stratum corneum (SC) act as a barrier and protect epidermal cells and thus the whole body against xenobiotica of the external environment. Topical skin treatment requires an efficient drug delivery system (DDS). Polymer-based nanocarriers represent novel transport vehicles for dermal application of drugs. In this study dendritic core-multishell (CMS) nanoparticles were investigated as promising candidates. CMS nanoparticles were loaded with a drug (analogue) and were applied to penetration studies of skin. We determined by dual-frequency electron paramagnetic resonance (EPR) how dexamethasone (Dx) labelled with 3-carboxy-2,2,5,5-tetramethyl-1-pyrrolidinyloxy (PCA) is associated with the CMS. The micro-environment of the drug loaded to CMS nanoparticles was investigated by pulsed high-field EPR at cryogenic temperature, making use of the fact that magnetic parameters (g-, A-matrices, and spin-lattice relaxation time) represent specific probes for the micro-environment. Additionally, the rotational correlation time of spin-labelled Dx was probed by continuous wave EPR at ambient temperature, which provides independent information on the drug environment. Furthermore, the penetration depth of Dx into the stratum corneum of porcine skin after different topical applications was investigated. The location of Dx in the CMS nanoparticles is revealed and the function of CMS as penetration enhancers for topical application is shown. Copyright © 2016 Elsevier B.V. All rights reserved.
Microlens performance limits in sub-2mum pixel CMOS image sensors.
Huo, Yijie; Fesenmaier, Christian C; Catrysse, Peter B
2010-03-15
CMOS image sensors with smaller pixels are expected to enable digital imaging systems with better resolution. When pixel size scales below 2 mum, however, diffraction affects the optical performance of the pixel and its microlens, in particular. We present a first-principles electromagnetic analysis of microlens behavior during the lateral scaling of CMOS image sensor pixels. We establish for a three-metal-layer pixel that diffraction prevents the microlens from acting as a focusing element when pixels become smaller than 1.4 microm. This severely degrades performance for on and off-axis pixels in red, green and blue color channels. We predict that one-metal-layer or backside-illuminated pixels are required to extend the functionality of microlenses beyond the 1.4 microm pixel node.
Mull, Hillary J; Chen, Qi; O'Brien, William J; Shwartz, Michael; Borzecki, Ann M; Hanchate, Amresh; Rosen, Amy K
2013-07-01
The Centers for Medicare and Medicaid Services' (CMS) all-cause readmission measure and the 3M Health Information System Division Potentially Preventable Readmissions (PPR) measure are both used for public reporting. These 2 methods have not been directly compared in terms of how they identify high-performing and low-performing hospitals. To examine how consistently the CMS and PPR methods identify performance outliers, and explore how the PPR preventability component impacts hospital readmission rates, public reporting on CMS' Hospital Compare website, and pay-for-performance under CMS' Hospital Readmission Reduction Program for 3 conditions (acute myocardial infarction, heart failure, and pneumonia). We applied the CMS all-cause model and the PPR software to VA administrative data to calculate 30-day observed FY08-10 VA hospital readmission rates and hospital profiles. We then tested the effect of preventability on hospital readmission rates and outlier identification for reporting and pay-for-performance by replacing the dependent variable in the CMS all-cause model (Yes/No readmission) with the dichotomous PPR outcome (Yes/No preventable readmission). The CMS and PPR methods had moderate correlations in readmission rates for each condition. After controlling for all methodological differences but preventability, correlations increased to >90%. The assessment of preventability yielded different outlier results for public reporting in 7% of hospitals; for 30% of hospitals there would be an impact on Hospital Readmission Reduction Program reimbursement rates. Despite uncertainty over which readmission measure is superior in evaluating hospital performance, we confirmed that there are differences in CMS-generated and PPR-generated hospital profiles for reporting and pay-for-performance, because of methodological differences and the PPR's preventability component.
A system for characterization of DEPFET silicon pixel matrices and test beam results
NASA Astrophysics Data System (ADS)
Furletov, Sergey; DEPFET Collaboration
2011-02-01
The DEPFET pixel detector offers first stage in-pixel amplification by incorporating a field effect transistor in the high resistivity silicon substrate. In this concept, a very small input capacitance can be realized thus allowing for low noise measurements. This makes DEPFET sensors a favorable technology for tracking in particle physics. Therefore a system with a DEPFET pixel matrix was developed to test DEPFET performance for an application as a vertex detector for the Belle II experiment. The system features a current based, row-wise readout of a DEPFET pixel matrix with a designated readout chip, steering chips for matrix control, a FPGA based data acquisition board, and a dedicated software package. The system was successfully operated in both test beam and lab environment. In 2009 new DEPFET matrices have been characterized in a 120 GeV pion beam at the CERN SPS. The current status of the DEPFET system and test beam results are presented.
Cost efficient command management
NASA Technical Reports Server (NTRS)
Brandt, Theresa; Murphy, C. W.; Kuntz, Jon; Barlett, Tom
1996-01-01
The design and implementation of a command management system (CMS) for a NASA control center, is described. The technology innovations implemented in the CMS provide the infrastructure required for operations cost reduction and future development cost reduction through increased operational efficiency and reuse in future missions. The command management design facilitates error-free operations which enables the automation of the routine control center functions and allows for the distribution of scheduling responsibility to the instrument teams. The reusable system was developed using object oriented methodologies.
Hyun, Soo-Wang; Kim, Bo-Ram; Lin, Dan; Hyun, Sung-Ae; Yoon, Seong Shoon; Seo, Joung-Wook
Cell culture media usually contains antibiotics including gentamicin or penicillin/streptomycin (PS) to protect cells from bacterial contamination. However, little is known about the effects of antibiotics on action potential and field potential parameters in human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). The present study examined the effects of gentamicin (10, 25, and 50μg/ml) and PS (50, 100, and 200U/μg/ml) on electrophysiological activity in spontaneously beating hiPSC-CMs using manual patch clamp and multi-electrode array. We also measured mRNA expression of cardiac ion channels in hiPSC-CMs grown in media with or without gentamicin (25μg/ml) using reverse transcription-polymerase chain reaction. We recorded action potential and field potential of hiPSC-CMs grown in the presence or absence of gentamicin or PS. We also observed action potential parameters in hiPSC-CMs after short-term treatment with these antibiotics. Changes in action potential and field potential parameters were observed in hiPSC-CMs grown in media containing gentamicin or PS. Treatment with PS also affected action potential parameters in hiPSC-CMs. In addition, the mRNA expression of cardiac sodium and potassium ion channels was significantly attenuated in hiPSC-CMs grown in the presence of gentamicin (25μg/ml). The present findings suggested that gentamicin should not be used in the culture media of hiPSC-CMs used for the measurement of electrophysiological parameters. Our findings also suggest that 100U/100μg/ml of PS are the maximum appropriate concentrations of these antibiotics for recording action potential waveform, because they did not influence action potential parameters in these cells. Copyright © 2017. Published by Elsevier Inc.
A detector interferometric calibration experiment for high precision astrometry
NASA Astrophysics Data System (ADS)
Crouzier, A.; Malbet, F.; Henault, F.; Léger, A.; Cara, C.; LeDuigou, J. M.; Preis, O.; Kern, P.; Delboulbe, A.; Martin, G.; Feautrier, P.; Stadler, E.; Lafrasse, S.; Rochat, S.; Ketchazo, C.; Donati, M.; Doumayrou, E.; Lagage, P. O.; Shao, M.; Goullioud, R.; Nemati, B.; Zhai, C.; Behar, E.; Potin, S.; Saint-Pe, M.; Dupont, J.
2016-11-01
Context. Exoplanet science has made staggering progress in the last two decades, due to the relentless exploration of new detection methods and refinement of existing ones. Yet astrometry offers a unique and untapped potential of discovery of habitable-zone low-mass planets around all the solar-like stars of the solar neighborhood. To fulfill this goal, astrometry must be paired with high precision calibration of the detector. Aims: We present a way to calibrate a detector for high accuracy astrometry. An experimental testbed combining an astrometric simulator and an interferometric calibration system is used to validate both the hardware needed for the calibration and the signal processing methods. The objective is an accuracy of 5 × 10-6 pixel on the location of a Nyquist sampled polychromatic point spread function. Methods: The interferometric calibration system produced modulated Young fringes on the detector. The Young fringes were parametrized as products of time and space dependent functions, based on various pixel parameters. The minimization of function parameters was done iteratively, until convergence was obtained, revealing the pixel information needed for the calibration of astrometric measurements. Results: The calibration system yielded the pixel positions to an accuracy estimated at 4 × 10-4 pixel. After including the pixel position information, an astrometric accuracy of 6 × 10-5 pixel was obtained, for a PSF motion over more than five pixels. In the static mode (small jitter motion of less than 1 × 10-3 pixel), a photon noise limited precision of 3 × 10-5 pixel was reached.
Dataset definition for CMS operations and physics analyses
NASA Astrophysics Data System (ADS)
Franzoni, Giovanni; Compact Muon Solenoid Collaboration
2016-04-01
Data recorded at the CMS experiment are funnelled into streams, integrated in the HLT menu, and further organised in a hierarchical structure of primary datasets and secondary datasets/dedicated skims. Datasets are defined according to the final-state particles reconstructed by the high level trigger, the data format and the use case (physics analysis, alignment and calibration, performance studies). During the first LHC run, new workflows have been added to this canonical scheme, to exploit at best the flexibility of the CMS trigger and data acquisition systems. The concepts of data parking and data scouting have been introduced to extend the physics reach of CMS, offering the opportunity of defining physics triggers with extremely loose selections (e.g. dijet resonance trigger collecting data at a 1 kHz). In this presentation, we review the evolution of the dataset definition during the LHC run I, and we discuss the plans for the run II.
Upgrades for the CMS simulation
Lange, D. J.; Hildreth, M.; Ivantchenko, V. N.; ...
2015-05-22
Over the past several years, the CMS experiment has made significant changes to its detector simulation application. The geometry has been generalized to include modifications being made to the CMS detector for 2015 operations, as well as model improvements to the simulation geometry of the current CMS detector and the implementation of a number of approved and possible future detector configurations. These include both completely new tracker and calorimetry systems. We have completed the transition to Geant4 version 10, we have made significant progress in reducing the CPU resources required to run our Geant4 simulation. These have been achieved throughmore » both technical improvements and through numerical techniques. Substantial speed improvements have been achieved without changing the physics validation benchmarks that the experiment uses to validate our simulation application for use in production. As a result, we will discuss the methods that we implemented and the corresponding demonstrated performance improvements deployed for our 2015 simulation application.« less
Zhou, Yang; Wang, Li; Liu, Ziqing; Alimohamadi, Sahar; Yin, Chaoying; Liu, Jiandong; Qian, Li
2017-09-26
Cardiomyocytes derived from induced pluripotent stem cells (iPSC-CMs) or directly reprogrammed from non-myocytes (induced cardiomyocytes [iCMs]) are promising sources for heart regeneration or disease modeling. However, the similarities and differences between iPSC-CMs and iCMs are still unknown. Here, we performed transcriptome analyses of beating iPSC-CMs and iCMs generated from cardiac fibroblasts (CFs) of the same origin. Although both iPSC-CMs and iCMs establish CM-like molecular features globally, iPSC-CMs exhibit a relatively hyperdynamic epigenetic status, whereas iCMs exhibit a maturation status that more closely resembles that of adult CMs. Based on gene expression of metabolic enzymes, iPSC-CMs primarily employ glycolysis, whereas iCMs utilize fatty acid oxidation as the main pathway. Importantly, iPSC-CMs and iCMs exhibit different cell-cycle status, alteration of which influenced their maturation. Therefore, our study provides a foundation for understanding the pros and cons of different reprogramming approaches. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Flexible trigger menu implementation on the Global Trigger for the CMS Level-1 trigger upgrade
NASA Astrophysics Data System (ADS)
MATSUSHITA, Takashi;
2017-10-01
The CMS experiment at the Large Hadron Collider (LHC) has continued to explore physics at the high-energy frontier in 2016. The integrated luminosity delivered by the LHC in 2016 was 41 fb-1 with a peak luminosity of 1.5 × 1034 cm-2s-1 and peak mean pile-up of about 50, all exceeding the initial estimations for 2016. The CMS experiment has upgraded its hardware-based Level-1 trigger system to maintain its performance for new physics searches and precision measurements at high luminosities. The Global Trigger is the final step of the CMS Level-1 trigger and implements a trigger menu, a set of selection requirements applied to the final list of objects from calorimeter and muon triggers, for reducing the 40 MHz collision rate to 100 kHz. The Global Trigger has been upgraded with state-of-the-art FPGA processors on Advanced Mezzanine Cards with optical links running at 10 GHz in a MicroTCA crate. The powerful processing resources of the upgraded system enable implementation of more algorithms at a time than previously possible, allowing CMS to be more flexible in how it handles the available trigger bandwidth. Algorithms for a trigger menu, including topological requirements on multi-objects, can be realised in the Global Trigger using the newly developed trigger menu specification grammar. Analysis-like trigger algorithms can be represented in an intuitive manner and the algorithms are translated to corresponding VHDL code blocks to build a firmware. The grammar can be extended in future as the needs arise. The experience of implementing trigger menus on the upgraded Global Trigger system will be presented.
Analysis of the Laser Calibration System for the CMS HCAL at CERN's Large Hadron Collider
NASA Astrophysics Data System (ADS)
Lebolo, Luis
2005-11-01
The European Organization for Nuclear Physics' (CERN) Large Hadron Collider uses the Compact Muon Solenoid (CMS) detector to measure collision products from proton-proton interactions. CMS uses a hadron calorimeter (HCAL) to measure the energy and position of quarks and gluons by reconstructing their hadronic decay products. An essential component of the detector is the calibration system, which was evaluated in terms of its misalignment, linearity, and resolution. In order to analyze the data, the authors created scripts in ROOT 5.02/00 and C++. The authors also used Mathematica 5.1 to perform complex mathematics and AutoCAD 2006 to produce optical ray traces. The misalignment of the optical components was found to be satisfactory; the Hybrid Photodiodes (HPDs) were confirmed to be linear; the constant, noise and stochastic contributions to its resolution were analyzed; and the quantum efficiency of most HPDs was determined to be approximately 40%. With a better understanding of the laser calibration system, one can further understand and improve the HCAL.
Learning Program for Enhancing Visual Literacy for Non-Design Students Using a CMS to Share Outcomes
ERIC Educational Resources Information Center
Ariga, Taeko; Watanabe, Takashi; Otani, Toshio; Masuzawa, Toshimitsu
2016-01-01
This study proposes a basic learning program for enhancing visual literacy using an original Web content management system (Web CMS) to share students' outcomes in class as a blog post. It seeks to reinforce students' understanding and awareness of the design of visual content. The learning program described in this research focuses on to address…
Grid site availability evaluation and monitoring at CMS
Lyons, Gaston; Maciulaitis, Rokas; Bagliesi, Giuseppe; ...
2017-10-01
The Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) uses distributed grid computing to store, process, and analyse the vast quantity of scientific data recorded every year. The computing resources are grouped into sites and organized in a tiered structure. Each site provides computing and storage to the CMS computing grid. Over a hundred sites worldwide contribute with resources from hundred to well over ten thousand computing cores and storage from tens of TBytes to tens of PBytes. In such a large computing setup scheduled and unscheduled outages occur continually and are not allowed to significantly impactmore » data handling, processing, and analysis. Unscheduled capacity and performance reductions need to be detected promptly and corrected. CMS developed a sophisticated site evaluation and monitoring system for Run 1 of the LHC based on tools of the Worldwide LHC Computing Grid. For Run 2 of the LHC the site evaluation and monitoring system is being overhauled to enable faster detection/reaction to failures and a more dynamic handling of computing resources. Furthermore, enhancements to better distinguish site from central service issues and to make evaluations more transparent and informative to site support staff are planned.« less
Grid site availability evaluation and monitoring at CMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyons, Gaston; Maciulaitis, Rokas; Bagliesi, Giuseppe
The Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) uses distributed grid computing to store, process, and analyse the vast quantity of scientific data recorded every year. The computing resources are grouped into sites and organized in a tiered structure. Each site provides computing and storage to the CMS computing grid. Over a hundred sites worldwide contribute with resources from hundred to well over ten thousand computing cores and storage from tens of TBytes to tens of PBytes. In such a large computing setup scheduled and unscheduled outages occur continually and are not allowed to significantly impactmore » data handling, processing, and analysis. Unscheduled capacity and performance reductions need to be detected promptly and corrected. CMS developed a sophisticated site evaluation and monitoring system for Run 1 of the LHC based on tools of the Worldwide LHC Computing Grid. For Run 2 of the LHC the site evaluation and monitoring system is being overhauled to enable faster detection/reaction to failures and a more dynamic handling of computing resources. Furthermore, enhancements to better distinguish site from central service issues and to make evaluations more transparent and informative to site support staff are planned.« less
One lens missing? Clarifying the clinical microsystem framework with learning theories.
Norman, Ann-Charlott; Fritzen, Lena; Fridh, Marianne Lindblad
2013-01-01
The clinical microsystem (CMS) approach is widely used and is perceived as helpful in practice but, we ask the question: "Is its learning potential sufficiently utilized?" To scrutinize aspects of learning within the CMS framework and to clarify the learning aspects the framework includes and thereby support the framework with the enhanced learning perspective that becomes visible. Literature on the CMS framework was systematically searched and selected using inclusion criteria. An analytical tool was constructed in the form of a theoretical lens that was used to clarify learning aspects that are associated with the framework. The analysis revealed 3 learning aspects: (1) The CMS framework describes individual and social learning but not how to adapt learning strategies for purposes of change. (2) The metaphorical language of how to reach a holistic health care system for each patient has developed over time but can still be improved by naming social interactions to transcend organizational boundaries. (3) Power structures are recognized but not as a characteristic that restricts learning due to asymmetric communication. The "lens" perspective reveals new meanings to learning that enhance our understanding of health care as a social system and provides new practical learning strategies.
Modelling and simulating a crisis management system: an organisational perspective
NASA Astrophysics Data System (ADS)
Chaawa, Mohamed; Thabet, Inès; Hanachi, Chihab; Ben Said, Lamjed
2017-04-01
Crises are complex situations due to the dynamism of the environment, its unpredictability and the complexity of the interactions among several different and autonomous involved organisations. In such a context, establishing an organisational view as well as structuring organisations' communications and their functioning is a crucial requirement. In this article, we propose a multi-agent organisational model (OM) to abstract, simulate and analyse a crisis management system (CMS). The objective is to evaluate the CMS from an organisational view, to assess its strength as well as its weakness and to provide deciders with some recommendations for a more flexible and reactive CMS. The proposed OM is illustrated through a real case study: a snowstorm in a Tunisian region. More precisely, we made the following contribution: firstly, we provide an environmental model that identifies the concepts involved in the crisis. Then, we define a role model that copes with the involved actors. In addition, we specify the organisational structure and the interaction model that rule communications and structure actors' functioning. Those models, built following the GAIA methodology, abstract the CMS from an organisational perspective. Finally, we implemented a customisable multi-agent simulator based on the Janus platform to analyse, through several performed simulations, the organisational model.
L1 track trigger for the CMS HL-LHC upgrade using AM chips and FPGAs
NASA Astrophysics Data System (ADS)
Fedi, Giacomo
2017-08-01
The increase of luminosity at the HL-LHC will require the introduction of tracker information in CMS's Level-1 trigger system to maintain an acceptable trigger rate when selecting interesting events, despite the order of magnitude increase in minimum bias interactions. To meet the latency requirements, dedicated hardware has to be used. This paper presents the results of tests of a prototype system (pattern recognition ezzanine) as core of pattern recognition and track fitting for the CMS experiment, combining the power of both associative memory custom ASICs and modern Field Programmable Gate Array (FPGA) devices. The mezzanine uses the latest available associative memory devices (AM06) and the most modern Xilinx Ultrascale FPGAs. The results of the test for a complete tower comprising about 0.5 million patterns is presented, using as simulated input events traversing the upgraded CMS detector. The paper shows the performance of the pattern matching, track finding and track fitting, along with the latency and processing time needed. The pT resolution over pT of the muons measured using the reconstruction algorithm is at the order of 1% in the range 3-100 GeV/c.
Grid site availability evaluation and monitoring at CMS
NASA Astrophysics Data System (ADS)
Lyons, Gaston; Maciulaitis, Rokas; Bagliesi, Giuseppe; Lammel, Stephan; Sciabà, Andrea
2017-10-01
The Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) uses distributed grid computing to store, process, and analyse the vast quantity of scientific data recorded every year. The computing resources are grouped into sites and organized in a tiered structure. Each site provides computing and storage to the CMS computing grid. Over a hundred sites worldwide contribute with resources from hundred to well over ten thousand computing cores and storage from tens of TBytes to tens of PBytes. In such a large computing setup scheduled and unscheduled outages occur continually and are not allowed to significantly impact data handling, processing, and analysis. Unscheduled capacity and performance reductions need to be detected promptly and corrected. CMS developed a sophisticated site evaluation and monitoring system for Run 1 of the LHC based on tools of the Worldwide LHC Computing Grid. For Run 2 of the LHC the site evaluation and monitoring system is being overhauled to enable faster detection/reaction to failures and a more dynamic handling of computing resources. Enhancements to better distinguish site from central service issues and to make evaluations more transparent and informative to site support staff are planned.
A histological ontology of the human cardiovascular system.
Mazo, Claudia; Salazar, Liliana; Corcho, Oscar; Trujillo, Maria; Alegre, Enrique
2017-10-02
In this paper, we describe a histological ontology of the human cardiovascular system developed in collaboration among histology experts and computer scientists. The histological ontology is developed following an existing methodology using Conceptual Models (CMs) and validated using OOPS!, expert evaluation with CMs, and how accurately the ontology can answer the Competency Questions (CQ). It is publicly available at http://bioportal.bioontology.org/ontologies/HO and https://w3id.org/def/System . The histological ontology is developed to support complex tasks, such as supporting teaching activities, medical practices, and bio-medical research or having natural language interactions.
1988-05-20
AVF Control Number: AVF-VSR-84.1087 ’S (0 87-03-10-TEL I- Ada® COMPILER VALIDATION SUMMARY REPORT: International Business Machines Corporation IBM...System, Version 1.1.0, International Business Machines Corporation, Wright-Patterson AFB. IBM 4381 under VM/SP CMS, Release 3.6 (host) and IBM 4381...an IBM 4381 operating under MVS, Release 3.8. On-site testing was performed 18 May 1987 through 20 May 1987 at International Business Machines
45 CFR 150.203 - Circumstances requiring CMS enforcement.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 1 2010-10-01 2010-10-01 false Circumstances requiring CMS enforcement. 150.203... CARE ACCESS CMS ENFORCEMENT IN GROUP AND INDIVIDUAL INSURANCE MARKETS CMS Enforcement Processes for... requiring CMS enforcement. CMS enforces HIPAA requirements to the extent warranted (as determined by CMS) in...
The utility of rat jejunal permeability for biopharmaceutics classification system.
Zakeri-Milani, Parvin; Valizadeh, Hadi; Tajerzadeh, Hosnieh; Islambulchilar, Ziba
2009-12-01
The biopharmaceutical classification system has been developed to provide a scientific approach for classifying drug compounds based on their dose/solubility ratio and human intestinal permeability. Therefore in this study a new classification is presented, which is based on a correlation between rat and human intestinal permeability values. In situ technique in rat jejunum was used to determine the effective intestinal permeability of tested drugs. Then three dimensionless parameters--dose number, absorption number, and dissolution number (D(o), A(n), and D(n))--were calculated for each drug. Four classes of drugs were defined, that is, class I, D(0) < 0.5, P(eff(rat)) > 5.09 x 10(-5) cm/s; class II, D(o) > 1, P(eff(rat)) > 5.09 x 10( -5) cm/s; class III, D(0) < 0.5, P(eff(rat)) < 4.2 x 10(-5) cm/s; and class IV, D(o) > 1, P(eff(rat)) < 4.2 x 10(-5) cm/s. A region of borderline drugs (0.5 < D(o) < 1, 4.2 x 10(-5) < P(eff(rat)) < 5.09 x 10(-5) cm/s) was also defined. According to obtained results and proposed classification for drugs, it is concluded that drugs could be categorized correctly based on dose number and their intestinal permeability values in rat model using single-pass intestinal perfusion technique. This classification enables us to remark defined characteristics for intestinal absorption of all four classes using suitable cutoff points for both dose number and rat effective intestinal permeability values.
CMS distributed data analysis with CRAB3
Mascheroni, M.; Balcas, J.; Belforte, S.; ...
2015-12-23
The CMS Remote Analysis Builder (CRAB) is a distributed workflow management tool which facilitates analysis tasks by isolating users from the technical details of the Grid infrastructure. Throughout LHC Run 1, CRAB has been successfully employed by an average of 350 distinct users each week executing about 200,000 jobs per day.CRAB has been significantly upgraded in order to face the new challenges posed by LHC Run 2. Components of the new system include 1) a lightweight client, 2) a central primary server which communicates with the clients through a REST interface, 3) secondary servers which manage user analysis tasks andmore » submit jobs to the CMS resource provisioning system, and 4) a central service to asynchronously move user data from temporary storage in the execution site to the desired storage location. Furthermore, the new system improves the robustness, scalability and sustainability of the service.Here we provide an overview of the new system, operation, and user support, report on its current status, and identify lessons learned from the commissioning phase and production roll-out.« less
Integration and validation testing for PhEDEx, DBS and DAS with the PhEDEx LifeCycle agent
NASA Astrophysics Data System (ADS)
Boeser, C.; Chwalek, T.; Giffels, M.; Kuznetsov, V.; Wildish, T.
2014-06-01
The ever-increasing amount of data handled by the CMS dataflow and workflow management tools poses new challenges for cross-validation among different systems within CMS experiment at LHC. To approach this problem we developed an integration test suite based on the LifeCycle agent, a tool originally conceived for stress-testing new releases of PhEDEx, the CMS data-placement tool. The LifeCycle agent provides a framework for customising the test workflow in arbitrary ways, and can scale to levels of activity well beyond those seen in normal running. This means we can run realistic performance tests at scales not likely to be seen by the experiment for some years, or with custom topologies to examine particular situations that may cause concern some time in the future. The LifeCycle agent has recently been enhanced to become a general purpose integration and validation testing tool for major CMS services. It allows cross-system integration tests of all three components to be performed in controlled environments, without interfering with production services. In this paper we discuss the design and implementation of the LifeCycle agent. We describe how it is used for small-scale debugging and validation tests, and how we extend that to large-scale tests of whole groups of sub-systems. We show how the LifeCycle agent can emulate the action of operators, physicists, or software agents external to the system under test, and how it can be scaled to large and complex systems.
A Study on Course Management System Implementation in Indonesian Higher Education Institutions
NASA Astrophysics Data System (ADS)
Saputra, Y. A.; Singgih, M. L.; Latiffianti, E.; Suryani, E.; Mudjahidin
2018-04-01
Information technology development nowadays has brought new colors in the higher education learning process. In Indonesia, the current trend showed a higher use of CMS to support the existing conventional learning method in the classrooms. This paper attempts to understand the characteristics of CMS implementation based on a survey at several higher education institutions in Indonesia. There were 9 selected higher education institutions observed in this study. The objectives were to find out the CMS implementation in terms of: 1) the management of CMS implementation, 2) the evaluation, 3) originality of materials, platform, and feature; and 4) participation level. The result showed that the use of CMS in these institutions, in general, was to support the classroom conventional learning method by providing a repository of lecture notes and communication forum/media outside the classroom. The management task mostly was taken care by a specific unit. A Moodle (freeware) was found as a typical platform in use, and none of the institutions chose to use paid platform i.e. Blackboard. The accessibility of CMS used was kept closed for limited group of people due to high cost of material originality assurance. Observation also found that there was not much attempts in evaluating the success of CMS implementation in each institution, whereas the success measurement was limited to the users’ satisfaction level. The majority of institutions claimed a good internal participation level (with lecturers and students as the main users), but in general we found that lecturer participation in most institutions were low or even very low.
Comparative transcript profiling of the fertile and sterile flower buds of pol CMS in B. napus.
An, Hong; Yang, Zonghui; Yi, Bin; Wen, Jing; Shen, Jinxiong; Tu, Jinxing; Ma, Chaozhi; Fu, Tingdong
2014-04-03
The Polima (pol) system of cytoplasmic male sterility (CMS) and its fertility restoration gene Rfp have been used in hybrid breeding in Brassica napus, which has greatly improved the yield of rapeseed. However, the mechanism of the male sterility transition in pol CMS remains to be determined. To investigate the transcriptome during the male sterility transition in pol CMS, a near-isogenic line (NIL) of pol CMS was constructed. The phenotypic features and sterility stage were confirmed by anatomical analysis. Subsequently, we compared the genomic expression profiles of fertile and sterile young flower buds by RNA-Seq. A total of 105,481,136 sequences were successfully obtained. These reads were assembled into 112,770 unigenes, which composed the transcriptome of the bud. Among these unigenes, 72,408 (64.21%) were annotated using public protein databases and classified into functional clusters. In addition, we investigated the changes in expression of the fertile and sterile buds; the RNA-seq data showed 1,148 unigenes had significantly different expression and they were mainly distributed in metabolic and protein synthesis pathways. Additionally, some unigenes controlling anther development were dramatically down-regulated in sterile buds. These results suggested that an energy deficiency caused by orf224/atp6 may inhibit a series of genes that regulate pollen development through nuclear-mitochondrial interaction. This results in the sterility of pol CMS by leading to the failure of sporogenous cell differentiation. This study may provide assistance for detailed molecular analysis and a better understanding of pol CMS in B. napus.
Preliminary investigations of active pixel sensors in Nuclear Medicine imaging
NASA Astrophysics Data System (ADS)
Ott, Robert; Evans, Noel; Evans, Phil; Osmond, J.; Clark, A.; Turchetta, R.
2009-06-01
Three CMOS active pixel sensors have been investigated for their application to Nuclear Medicine imaging. Startracker with 525×525 25 μm square pixels has been coupled via a fibre optic stud to a 2 mm thick segmented CsI(Tl) crystal. Imaging tests were performed using 99mTc sources, which emit 140 keV gamma rays. The system was interfaced to a PC via FPGA-based DAQ and optical link enabling imaging rates of 10 f/s. System noise was measured to be >100e and it was shown that the majority of this noise was fixed pattern in nature. The intrinsic spatial resolution was measured to be ˜80 μm and the system spatial resolution measured with a slit was ˜450 μm. The second sensor, On Pixel Intelligent CMOS (OPIC), had 64×72 40 μm pixels and was used to evaluate noise characteristics and to develop a method of differentiation between fixed pattern and statistical noise. The third sensor, Vanilla, had 520×520 25 μm pixels and a measured system noise of ˜25e. This sensor was coupled directly to the segmented phosphor. Imaging results show that even at this lower level of noise the signal from 140 keV gamma rays is small as the light from the phosphor is spread over a large number of pixels. Suggestions for the 'ideal' sensor are made.
The CMS Tier0 goes cloud and grid for LHC Run 2
Hufnagel, Dirk
2015-12-23
In 2015, CMS will embark on a new era of collecting LHC collisions at unprecedented rates and complexity. This will put a tremendous stress on our computing systems. Prompt Processing of the raw data by the Tier-0 infrastructure will no longer be constrained to CERN alone due to the significantly increased resource requirements. In LHC Run 2, we will need to operate it as a distributed system utilizing both the CERN Cloud-based Agile Infrastructure and a significant fraction of the CMS Tier-1 Grid resources. In another big change for LHC Run 2, we will process all data using the multi-threadedmore » framework to deal with the increased event complexity and to ensure efficient use of the resources. Furthermore, this contribution will cover the evolution of the Tier-0 infrastructure and present scale testing results and experiences from the first data taking in 2015.« less
Amorim-Costa, C; Ayres-de-Campos, D; Costa-Santos, C; Bernardes, J
2014-01-01
Digital storage of cardiotocographic (CTG) tracings by fetal central monitoring systems (fCMS) obviates the need for printing, or alternatively, the tracings can be printed in regular paper instead of CTG thermal paper. We aimed at evaluating the impact of the introduction of the Omniview-SisPorto(®) system on CTG paper costs in a large university hospital. After introduction of the fCMS, there was an 87% reduction in median annual expenses with CTG paper in the labour ward (p = 0.011) and a 78% decrease in the prenatal clinic (p = 0.017), despite a more than 40% increase in the median number of observed women. Routine use of fCMS may provide an important reduction in hospital expenses associated with the use of thermal CTG paper, thus reducing the investment made in their acquisition and maintenance.
The CMS TierO goes Cloud and Grid for LHC Run 2
NASA Astrophysics Data System (ADS)
Hufnagel, Dirk
2015-12-01
In 2015, CMS will embark on a new era of collecting LHC collisions at unprecedented rates and complexity. This will put a tremendous stress on our computing systems. Prompt Processing of the raw data by the Tier-0 infrastructure will no longer be constrained to CERN alone due to the significantly increased resource requirements. In LHC Run 2, we will need to operate it as a distributed system utilizing both the CERN Cloud-based Agile Infrastructure and a significant fraction of the CMS Tier-1 Grid resources. In another big change for LHC Run 2, we will process all data using the multi-threaded framework to deal with the increased event complexity and to ensure efficient use of the resources. This contribution will cover the evolution of the Tier-0 infrastructure and present scale testing results and experiences from the first data taking in 2015.
Myosin light chain 2-based selection of human iPSC-derived early ventricular cardiac myocytes
Bizy, Alexandra; Guerrero-Serna, Guadalupe; Hu, Bin; Ponce-Balbuena, Daniela; Willis, B. Cicero; Zarzoso, Manuel; Ramirez, Rafael J.; Sener, Michelle F.; Mundada, Lakshmi V.; Klos, Matthew; Devaney, Eric J.; Vikstrom, Karen L.; Herron, Todd J.; Jalife, José
2014-01-01
Applications of human induced pluripotent stemcell derived-cardiac myocytes (hiPSC-CMs) would be strengthened by the ability to generate specific cardiac myocyte (CM) lineages. However, purification of lineage-specific hiPSC-CMs is limited by the lack of cell marking techniques. Here, we have developed an iPSC-CM marking system using recombinant adenoviral reporter constructs with atrial- or ventricular-specific myosin light chain-2 (MLC-2) promoters. MLC-2a and MLC-2v selected hiPSC-CMs were purified by fluorescence-activated cell sorting and their biochemical and electrophysiological phenotypes analyzed. We demonstrate that the phenotype of both populations remained stable in culture and they expressed the expected sarcomeric proteins, gap junction proteins and chamber-specific transcription factors. Compared to MLC-2a cells, MLC-2v selected CMs had larger action potential amplitudes and durations. In addition, by immunofluorescence, we showed that MLC-2 isoform expression can be used to enrich hiPSC-CM consistent with early atrial and ventricularmyocyte lineages. However, only the ventricular myosin light chain-2 promoter was able to purify a highly homogeneous population of iPSC-CMs. Using this approach, it is now possible to develop ventricular-specific disease models using iPSC-CMs while atrial-specific iPSC-CM cultures may require additional chamber-specific markers. PMID:24095945
Myosin light chain 2-based selection of human iPSC-derived early ventricular cardiac myocytes.
Bizy, Alexandra; Guerrero-Serna, Guadalupe; Hu, Bin; Ponce-Balbuena, Daniela; Willis, B Cicero; Zarzoso, Manuel; Ramirez, Rafael J; Sener, Michelle F; Mundada, Lakshmi V; Klos, Matthew; Devaney, Eric J; Vikstrom, Karen L; Herron, Todd J; Jalife, José
2013-11-01
Applications of human induced pluripotent stem cell derived-cardiac myocytes (hiPSC-CMs) would be strengthened by the ability to generate specific cardiac myocyte (CM) lineages. However, purification of lineage-specific hiPSC-CMs is limited by the lack of cell marking techniques. Here, we have developed an iPSC-CM marking system using recombinant adenoviral reporter constructs with atrial- or ventricular-specific myosin light chain-2 (MLC-2) promoters. MLC-2a and MLC-2v selected hiPSC-CMs were purified by fluorescence-activated cell sorting and their biochemical and electrophysiological phenotypes analyzed. We demonstrate that the phenotype of both populations remained stable in culture and they expressed the expected sarcomeric proteins, gap junction proteins and chamber-specific transcription factors. Compared to MLC-2a cells, MLC-2v selected CMs had larger action potential amplitudes and durations. In addition, by immunofluorescence, we showed that MLC-2 isoform expression can be used to enrich hiPSC-CM consistent with early atrial and ventricular myocyte lineages. However, only the ventricular myosin light chain-2 promoter was able to purify a highly homogeneous population of iPSC-CMs. Using this approach, it is now possible to develop ventricular-specific disease models using iPSC-CMs while atrial-specific iPSC-CM cultures may require additional chamber-specific markers. © 2013.
First images of a digital autoradiography system based on a Medipix2 hybrid silicon pixel detector.
Mettivier, Giovanni; Montesi, Maria Cristina; Russo, Paolo
2003-06-21
We present the first images of beta autoradiography obtained with the high-resolution hybrid pixel detector consisting of the Medipix2 single photon counting read-out chip bump-bonded to a 300 microm thick silicon pixel detector. This room temperature system has 256 x 256 square pixels of 55 microm pitch (total sensitive area of 14 x 14 mm2), with a double threshold discriminator and a 13-bit counter in each pixel. It is read out via a dedicated electronic interface and control software, also developed in the framework of the European Medipix2 Collaboration. Digital beta autoradiograms of 14C microscale standard strips (containing separate bands of increasing specific activity in the range 0.0038-32.9 kBq g(-1)) indicate system linearity down to a total background noise of 1.8 x 10(-3) counts mm(-2) s(-1). The minimum detectable activity is estimated to be 0.012 Bq for 36,000 s exposure and 0.023 Bq for 10,800 s exposure. The measured minimum detection threshold is less than 1600 electrons (equivalent to about 6 keV Si). This real-time system for beta autoradiography offers lower pixel pitch and higher sensitive area than the previous Medipix1-based system. It has a 14C sensitivity better than that of micro channel plate based systems, which, however, shows higher spatial resolution and sensitive area.
Experimental single-chip color HDTV image acquisition system with 8M-pixel CMOS image sensor
NASA Astrophysics Data System (ADS)
Shimamoto, Hiroshi; Yamashita, Takayuki; Funatsu, Ryohei; Mitani, Kohji; Nojiri, Yuji
2006-02-01
We have developed an experimental single-chip color HDTV image acquisition system using 8M-pixel CMOS image sensor. The sensor has 3840 × 2160 effective pixels and is progressively scanned at 60 frames per second. We describe the color filter array and interpolation method to improve image quality with a high-pixel-count single-chip sensor. We also describe an experimental image acquisition system we used to measured spatial frequency characteristics in the horizontal direction. The results indicate good prospects for achieving a high quality single chip HDTV camera that reduces pseudo signals and maintains high spatial frequency characteristics within the frequency band for HDTV.
Marchand, Sandrine; Lamarche, Isabelle; Gobin, Patrice; Couet, William
2010-08-01
The aim of this study was to evaluate the effect of colistin methanesulphonate (CMS) dose on CMS and colistin pharmacokinetics in rats. Three rats per group received an intravenous bolus of CMS at a dose of 5, 15, 30, 60 or 120 mg/kg. Arterial blood samples were drawn at 0, 5, 15, 30, 60, 90, 120, 150 and 180 min. CMS and colistin plasma concentrations were determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pharmacokinetic parameters of CMS and colistin were calculated by non-compartmental analysis. Linear relationships were observed between CMS and colistin AUCs to infinity and CMS doses, as well as between CMS and colistin C(max) and CMS doses. CMS and colistin pharmacokinetics were linear for a range of colistin concentrations covering the range of values encountered and recommended in patients even during treatment with higher doses.
Smart-Pixel Array Processors Based on Optimal Cellular Neural Networks for Space Sensor Applications
NASA Technical Reports Server (NTRS)
Fang, Wai-Chi; Sheu, Bing J.; Venus, Holger; Sandau, Rainer
1997-01-01
A smart-pixel cellular neural network (CNN) with hardware annealing capability, digitally programmable synaptic weights, and multisensor parallel interface has been under development for advanced space sensor applications. The smart-pixel CNN architecture is a programmable multi-dimensional array of optoelectronic neurons which are locally connected with their local neurons and associated active-pixel sensors. Integration of the neuroprocessor in each processor node of a scalable multiprocessor system offers orders-of-magnitude computing performance enhancements for on-board real-time intelligent multisensor processing and control tasks of advanced small satellites. The smart-pixel CNN operation theory, architecture, design and implementation, and system applications are investigated in detail. The VLSI (Very Large Scale Integration) implementation feasibility was illustrated by a prototype smart-pixel 5x5 neuroprocessor array chip of active dimensions 1380 micron x 746 micron in a 2-micron CMOS technology.
Full complex spatial filtering with a phase mostly DMD. [Deformable Mirror Device
NASA Technical Reports Server (NTRS)
Florence, James M.; Juday, Richard D.
1991-01-01
A new technique for implementing fully complex spatial filters with a phase mostly deformable mirror device (DMD) light modulator is described. The technique combines two or more phase-modulating flexure-beam mirror elements into a single macro-pixel. By manipulating the relative phases of the individual sub-pixels within the macro-pixel, the amplitude and the phase can be independently set for this filtering element. The combination of DMD sub-pixels into a macro-pixel is accomplished by adjusting the optical system resolution, thereby trading off system space bandwidth product for increased filtering flexibility. Volume in the larger dimensioned space, space bandwidth-complex axes count, is conserved. Experimental results are presented mapping out the coupled amplitude and phase characteristics of the individual flexure-beam DMD elements and demonstrating the independent control of amplitude and phase in a combined macro-pixel. This technique is generally applicable for implementation with any type of phase modulating light modulator.
NASA Astrophysics Data System (ADS)
List of Posters: Dark matter annihilation in the Galactic galo, by Dokuchaev Vyacheslav, et al. NEMO developments towards km3 telescope in the Mediterranean Sea. The NEMO project. Neutrino Mediterranean Observatory By Antonio Capone, NEMO Collaboration. Alignment as a result from QCD jet production or new still unknown physics at LHC? By Alexander Snigirev. Small-scale fluctuations of extensive air showers: systematics in energy and muon density estimation By Grigory Rubtsov. SHINIE: Simulation of High-Energy Neutrino Interacting with the Earth By Lin Guey-Lin, et al.. Thermodynamics of rotating solutions in n+1 dimensional Einstein - Maxwell -dilation gravity By Ahmad Sheykhi, et al.. Supernova neutrino physics with future large Cherenkov detectors By Daniele Montanino. Crossing of the Cosmological Constant Barrier in the string Inspired Dark Energy Model By S. Yu. Vernov. Calculations of radio signals produced by ultra-high and extremely high energy neutrino induced cascades in Antarctic ice By D. Besson, et al.. Inflation, Cosmic Acceleration and string Gravity By Ischwaree Neupane. Neutrino Physics: Charm and J/Psi production in the atmosphere By Liudmila Volkova. Three generation flavor transitions and decays of supernova relic neutrinos By Daniele Montanino. Lattice calculations & computational quantum field theory: Sonification of Quark and Baryon Spectra By Markum Harald, et al.. Generalized Kramers-Wannier Duality for spin systems with non-commutative symmetry By V. M. Buchstaber, et al.. Heavy ion collisions & quark matter: Nuclear matter jets and multifragmentation By Danut Argintaru, et al.. QCD hard interactions: The qT-spectrum of the Higgs and Slepton-pairs at the LHC By Guiseppe Bozzi. QCD soft interactions: Nonperturbative effects in Single-Spin Asymmetries: Instantons and TMD-parton distributions By Igor Cherednikov, et al.. Gluon dominance model and high multiplicity By Elena Kokoulina. Resonances in eta pi- pi- pi+ system By Dmitry Ryabchikov. Saturation effects in diffractive scattering at LHC By Oleg Selugin. A nonperturbative expansion method in QCD and R-related quantities By Igor Solovtsov. Z-scaling and high multiplicity particle Production in bar pp/pp & AA collisions at Tevatron and RHIC By Mikhail Tokarev. Scaling behaviour of the reactionsdd - > p↑ /3H and pd - > pd with pT at energy I-2 GeV By Yuri Uzikov. [ADS Note: Title formula can not be rendered correctly in ASCII.] CP violation, rare decays, CKM: Precision Measurements of the Mass of the Top Quark at CDF (Precision Top Mass Measurements at CDF) By Daniel Whiteson. Measurement of the Bs Oscillation at CDF By Luciano Ristori. The Bs mixing phase at LHCb By J. J. van Hunen. ATLAS preparations for precise measurements of semileptonic rare B decays By K. Toms. Hadron spectroscopy & exotics: Searches for radial excited states of charmonium in experiments using cooled antiproton beams By M. Yu. Barabanov. Retardation effects in the rotating string model By Fabien Buisseret and Claude Semay. Final results from VEPP-2M (CMD-2 and SND) By G. V. Fedotovich. Heavy Quark Physics: Prospects for B physics measurements using the CMS detector at the LHC By Andreev Valery. Heavy flavour production at HERA-B By Andrey Bogatyrev. B-Meson subleading form factors in the Heavy Quark Effective Theory (HQET) By Frederic Jugeau. Beyond the Standard Model: Monopole Decay in a Variable External Field By Andrey Zayakin. Two-Loop matching coefficients for the strong coupling in the MSSM By Mihaila Luminita. Test of lepton flavour violation at LHC By Hidaka Keisho. Looking at New Physics through 4 jets and no ET By Maity Manas. Are Preons Dyons? Naturalness of Three Generations By Das Chitta Ranjan. SUSY Dark Matter at Linear Collider By Sezen Sekmen, Mehmet Zeyrek. MSSM light Higgs boson scenario and its test at hadron colliders By Alexander Belyaev. Antiscalar Approach to Gravity and Standard Model By E. Mychelkin. GRID distributed analysis in high energy physics: PAX: Physics Analysis Design and Application on the GRID By Martin Erdmann, et al.. D0 and the (SAM) GRID: An ongoing success story DO Collaboration. R & D for future accelerators, detectors & new facilities: High Level Trigger Selection in the CMS experiment By Monica Vazquez Acosta. R&D for a Helical Undulator Based Positron Source for the International Linear Collider By Phil Allport. Muon Detection, Reconstruction and Identification in CMS By Ivan Belotelov. Acoustic Measurements for EeV Neutrino Detection at the South Pole By Sebastian Böser. The PSI source of ultracold neutrons (UCN) By Manfred Daum. The LHCb Pixel Hybrid Photon Detectors (Characterization of Nybrig Photon Detectors for the LHCb experiment) By Neville Harnew, et al.. Semi-Insulating GaN-radiation hard semiconductor for ionizing radiation detectors By Juozas Vaitkus. Monitored Drift Tube end-cap spectrometer for the ATLAS detector By Dmitri Kotchetkov. Development of Focusing Aerogel RICH By Sergey Kononov, et al.. Electromagnetic Calibration of the Hadronic Tile Calorimeter Modules of the ATLAS detector at the LHC By Iouri Koultchitski. A Study of Proximity focusing RICH with Multiple Refractive Index Aerogel Radiator By Peter Krizan. The Heavy Flavor Tracker (HFT) for STAR By Vasil Kuspil. ATLAS Liquid Argon Calorimeter ATLAS Collaboration: Field Emission in HEP Colliders Initiated by a Relativistic Positively Charged Bunch of Particles By Boris Levchenko. MICE: the international Muon Ionization Cooling Experiment By Kenneth Long. In situ calibration of the CMS electromagnetic calorimeter By Augustino Lorenzo. The Transition Radiation Tracker for the ATLAS experiment at the LHC By Victor Maleev. Resonance depolarization and Compton-Backscattering technique for beam energy measurement of VEPP-4M collider By Ivan Nikolaev, et al.. CCD - based Pixel Detectors by LCFI By Andrei Nomerotski. The SiD Detector Concept for the International Linear Collider By Dmitry Onoprienko. CMS Hadron Calorimetry, Calibration, and Jets/Missing Transverse Energy Measurements By Sergey Petrushanko. The CMS Silicon Tracker By Oliver Pooth. Drift Chamber for CMD-3 detector By Alexandr Popov, et al.. Vacuum Phototriods for the CMS ECAL Endcap crystal calorimeter By Vladimir Postoev. CMS Silicon Tracker: Track Reconstruction and Alignment By Frank-Peter Schilling. eRHIC - A precision electron-proton/ion collider facility at Brookhaven National Laboratory By Bernd Surrow. Development of tracking detectors with industrially produced GEM foils By Bernd Surrow, et al.. A Linear Collider Facility with High Intensity e+e- beams (A high intensity e+e- Linear Collider Facility at low energy) By Andre Schoening. Construction of the BESIII detector for tau-charm physics By Yifang Wang. The HERMES Recoil Detector By Sergey Yashchenko. Simulation of MICE in G4 MICE MICE Experiment: The new DO Layer O silicon detector The DO trigger upgrade for RUNIIb The Do Collaboration. Operational experiences with the silicon detector at CDF By Jeannine Wagner. Mathematical aspects of QFT & string theory: Electron in superstrong Coulomb field By D. Gitman. Stability of a non-commutative Jackiw-Teitelboim gravity By Fresneda Rodrigo, et al.. 4d gravity localized on thick branes: the complete mass spectrum By Alfredo Herrera-Aguilar. On Emergence of Quantum Mechanics By L. V. Prokhorov.
Regional CMS Modeling: Southwest Florida Gulf Coast
2016-05-01
by Kelly R. Legault and Tanya M. Beck PURPOSE: This Coastal and Hydraulics Engineering technical note (CHETN) describes a regional application of...the U.S. Army Corps of Engineers (USACE) Engineer Research and Development Center (ERDC) Coastal Modeling System (CMS). This application spans three...Active federal projects include the Pinellas County Shore Protection Project (SPP), Tampa Harbor Deeping Project, Manatee County SPP at Anna Maria
40 CFR Table 7 to Subpart Mmmmm of... - Applicability of General Provisions to Subpart MMMMM
Code of Federal Regulations, 2010 CFR
2010-07-01
... alternative test method Yes. § 63.7(g) Performance test data analysis, recordkeeping, and reporting Yes. § 63... emissions monitoring systems (CEMS). § 63.8(g) Data reduction Yes Applies as modified by § 63.8794(g). § 63... CMS notifications—date of CMS performance evaluation Yes. § 63.9(g)(2) Use of COMS data No Subpart...
The CMS Level-1 Calorimeter Trigger for LHC Run II
NASA Astrophysics Data System (ADS)
Sinthuprasith, Tutanon
2017-01-01
The phase-1 upgrades of the CMS Level-1 calorimeter trigger have been completed. The Level-1 trigger has been fully commissioned and it will be used by CMS to collect data starting from the 2016 data run. The new trigger has been designed to improve the performance at high luminosity and large number of simultaneous inelastic collisions per crossing (pile-up). For this purpose it uses a novel design, the Time Multiplexed Design, which enables the data from an event to be processed by a single trigger processor at full granularity over several bunch crossings. The TMT design is a modular design based on the uTCA standard. The architecture is flexible and the number of trigger processors can be expanded according to the physics needs of CMS. Intelligent, more complex, and innovative algorithms are now the core of the first decision layer of CMS: the upgraded trigger system implements pattern recognition and MVA (Boosted Decision Tree) regression techniques in the trigger processors for pT assignment, pile up subtraction, and isolation requirements for electrons, and taus. The performance of the TMT design and the latency measurements and the algorithm performance which has been measured using data is also presented here.
Design of measuring system for wire diameter based on sub-pixel edge detection algorithm
NASA Astrophysics Data System (ADS)
Chen, Yudong; Zhou, Wang
2016-09-01
Light projection method is often used in measuring system for wire diameter, which is relatively simpler structure and lower cost, and the measuring accuracy is limited by the pixel size of CCD. Using a CCD with small pixel size can improve the measuring accuracy, but will increase the cost and difficulty of making. In this paper, through the comparative analysis of a variety of sub-pixel edge detection algorithms, polynomial fitting method is applied for data processing in measuring system for wire diameter, to improve the measuring accuracy and enhance the ability of anti-noise. In the design of system structure, light projection method with orthogonal structure is used for the detection optical part, which can effectively reduce the error caused by line jitter in the measuring process. For the electrical part, ARM Cortex-M4 microprocessor is used as the core of the circuit module, which can not only drive double channel linear CCD but also complete the sampling, processing and storage of the CCD video signal. In addition, ARM microprocessor can complete the high speed operation of the whole measuring system for wire diameter in the case of no additional chip. The experimental results show that sub-pixel edge detection algorithm based on polynomial fitting can make up for the lack of single pixel size and improve the precision of measuring system for wire diameter significantly, without increasing hardware complexity of the entire system.
Simulation Evaluation of Controller-Managed Spacing Tools under Realistic Operational Conditions
NASA Technical Reports Server (NTRS)
Callantine, Todd J.; Hunt, Sarah M.; Prevot, Thomas
2014-01-01
Controller-Managed Spacing (CMS) tools have been developed to aid air traffic controllers in managing high volumes of arriving aircraft according to a schedule while enabling them to fly efficient descent profiles. The CMS tools are undergoing refinement in preparation for field demonstration as part of NASA's Air Traffic Management (ATM) Technology Demonstration-1 (ATD-1). System-level ATD-1 simulations have been conducted to quantify expected efficiency and capacity gains under realistic operational conditions. This paper presents simulation results with a focus on CMS-tool human factors. The results suggest experienced controllers new to the tools find them acceptable and can use them effectively in ATD-1 operations.
NASA Astrophysics Data System (ADS)
Vandenberghe, Stefaan; Staelens, Steven; Byrne, Charles L.; Soares, Edward J.; Lemahieu, Ignace; Glick, Stephen J.
2006-06-01
In discrete detector PET, natural pixels are image basis functions calculated from the response of detector pairs. By using reconstruction with natural pixel basis functions, the discretization of the object into a predefined grid can be avoided. Here, we propose to use generalized natural pixel reconstruction. Using this approach, the basis functions are not the detector sensitivity functions as in the natural pixel case but uniform parallel strips. The backprojection of the strip coefficients results in the reconstructed image. This paper proposes an easy and efficient way to generate the matrix M directly by Monte Carlo simulation. Elements of the generalized natural pixel system matrix are formed by calculating the intersection of a parallel strip with the detector sensitivity function. These generalized natural pixels are easier to use than conventional natural pixels because the final step from solution to a square pixel representation is done by simple backprojection. Due to rotational symmetry in the PET scanner, the matrix M is block circulant and only the first blockrow needs to be stored. Data were generated using a fast Monte Carlo simulator using ray tracing. The proposed method was compared to a listmode MLEM algorithm, which used ray tracing for doing forward and backprojection. Comparison of the algorithms with different phantoms showed that an improved resolution can be obtained using generalized natural pixel reconstruction with accurate system modelling. In addition, it was noted that for the same resolution a lower noise level is present in this reconstruction. A numerical observer study showed the proposed method exhibited increased performance as compared to a standard listmode EM algorithm. In another study, more realistic data were generated using the GATE Monte Carlo simulator. For these data, a more uniform contrast recovery and a better contrast-to-noise performance were observed. It was observed that major improvements in contrast recovery were obtained with MLEM when the correct system matrix was used instead of simple ray tracing. The correct modelling was the major cause of improved contrast for the same background noise. Less important factors were the choice of the algorithm (MLEM performed better than ART) and the basis functions (generalized natural pixels gave better results than pixels).
Rapid Damage Assessment. Volume II. Development and Testing of Rapid Damage Assessment System.
1981-02-01
pixels/s Camera Line Rate 732.4 lines/s Pixels per Line 1728 video 314 blank 4 line number (binary) 2 run number (BCD) 2048 total Pixel Resolution 8 bits...sists of an LSI-ll microprocessor, a VDI -200 video display processor, an FD-2 dual floppy diskette subsystem, an FT-I function key-trackball module...COMPONENT LIST FOR IMAGE PROCESSOR SYSTEM IMAGE PROCESSOR SYSTEM VIEWS I VDI -200 Display Processor Racks, Table FD-2 Dual Floppy Diskette Subsystem FT-l
Communication system analysis for manned space flight
NASA Technical Reports Server (NTRS)
Schilling, D. L.
1977-01-01
One- and two-dimensional adaptive delta modulator (ADM) algorithms are discussed and compared. Results are shown for bit rates of two bits/pixel, one bit/pixel and 0.5 bits/pixel. Pictures showing the difference between the encoded-decoded pictures and the original pictures are presented. The effect of channel errors on the reconstructed picture is illustrated. A two-dimensional ADM using interframe encoding is also presented. This system operates at the rate of two bits/pixel and produces excellent quality pictures when there is little motion. The effect of large amounts of motion on the reconstructed picture is described.
Imaging through scattering media by Fourier filtering and single-pixel detection
NASA Astrophysics Data System (ADS)
Jauregui-Sánchez, Y.; Clemente, P.; Lancis, J.; Tajahuerce, E.
2018-02-01
We present a novel imaging system that combines the principles of Fourier spatial filtering and single-pixel imaging in order to recover images of an object hidden behind a turbid medium by transillumination. We compare the performance of our single-pixel imaging setup with that of a conventional system. We conclude that the introduction of Fourier gating improves the contrast of images in both cases. Furthermore, we show that the combination of single-pixel imaging and Fourier spatial filtering techniques is particularly well adapted to provide images of objects transmitted through scattering media.
Feaster, Tromondae K; Cadar, Adrian G; Wang, Lili; Williams, Charles H; Chun, Young Wook; Hempel, Jonathan E; Bloodworth, Nathaniel; Merryman, W David; Lim, Chee Chew; Wu, Joseph C; Knollmann, Björn C; Hong, Charles C
2015-12-04
The lack of measurable single-cell contractility of human-induced pluripotent stem cell-derived cardiac myocytes (hiPSC-CMs) currently limits the utility of hiPSC-CMs for evaluating contractile performance for both basic research and drug discovery. To develop a culture method that rapidly generates contracting single hiPSC-CMs and allows quantification of cell shortening with standard equipment used for studying adult CMs. Single hiPSC-CMs were cultured for 5 to 7 days on a 0.4- to 0.8-mm thick mattress of undiluted Matrigel (mattress hiPSC-CMs) and compared with hiPSC-CMs maintained on a control substrate (<0.1-mm thick 1:60 diluted Matrigel, control hiPSC-CMs). Compared with control hiPSC-CMs, mattress hiPSC-CMs had more rod-shape morphology and significantly increased sarcomere length. Contractile parameters of mattress hiPSC-CMs measured with video-based edge detection were comparable with those of freshly isolated adult rabbit ventricular CMs. Morphological and contractile properties of mattress hiPSC-CMs were consistent across cryopreserved hiPSC-CMs generated independently at another institution. Unlike control hiPSC-CMs, mattress hiPSC-CMs display robust contractile responses to positive inotropic agents, such as myofilament calcium sensitizers. Mattress hiPSC-CMs exhibit molecular changes that include increased expression of the maturation marker cardiac troponin I and significantly increased action potential upstroke velocity because of a 2-fold increase in sodium current (INa). The Matrigel mattress method enables the rapid generation of robustly contracting hiPSC-CMs and enhances maturation. This new method allows quantification of contractile performance at the single-cell level, which should be valuable to disease modeling, drug discovery, and preclinical cardiotoxicity testing. © 2015 American Heart Association, Inc.
Pixelated coatings and advanced IR coatings
NASA Astrophysics Data System (ADS)
Pradal, Fabien; Portier, Benjamin; Oussalah, Meihdi; Leplan, Hervé
2017-09-01
Reosc developed pixelated infrared coatings on detector. Reosc manufactured thick pixelated multilayer stacks on IR-focal plane arrays for bi-spectral imaging systems, demonstrating high filter performance, low crosstalk, and no deterioration of the device sensitivities. More recently, a 5-pixel filter matrix was designed and fabricated. Recent developments in pixelated coatings, shows that high performance infrared filters can be coated directly on detector for multispectral imaging. Next generation space instrument can benefit from this technology to reduce their weight and consumptions.
Ge, Lin; Zhu, Ming-Ming; Yang, Jing-Yu; Wang, Fang; Zhang, Rong; Zhang, Jing-Hai; Shen, Jing; Tian, Hui-Fang; Wu, Chun-Fu
2015-04-01
Depression is a complex psychiatric disorder, and its etiology and pathophysiology are not completely understood. Depression involves changes in many biogenic amine, neuropeptide, and oxidative systems, as well as alterations in neuroendocrine function and immune-inflammatory pathways. Oleamide is a fatty amide which exhibits pharmacological effects leading to hypnosis, sedation, and anti-anxiety effects. In the present study, the chronic mild stress (CMS) model was used to investigate the antidepressant-like activity of oleamide. Rats were exposed to 10weeks of CMS or control conditions and were then subsequently treated with 2weeks of daily oleamide (5mg/kg, i.p.), fluoxetine (10mg/kg, i.p.), or vehicle. Protein extracts from the hippocampus were then collected, and hippocampal maps were generated by way of two-dimensional gel electrophoresis (2-DE). Altered proteins induced by CMS and oleamide were identified through mass spectrometry and database searches. Compared to the control group, the CMS rats exhibited significantly less body weight gain and decreased sucrose consumption. Treatment with oleamide caused a reversal of the CMS-induced deficit in sucrose consumption. In the proteomic analysis, 12 protein spots were selected and identified. CMS increased the levels of adenylate kinase isoenzyme 1 (AK1), nucleoside diphosphate kinase B (NDKB), histidine triad nucleotide-binding protein 1 (HINT1), acyl-protein thioesterase 2 (APT-2), and glutathione S-transferase A4 (GSTA4). Compared to the CMS samples, seven spots changed significantly following treatment with oleamide, including GSTA4, glutathione S-transferase A6 (GSTA6), GTP-binding nuclear protein Ran (Ran-GTP), ATP synthase subunit d, transgelin-3, small ubiquitin-related modifier 2 (SUMO2), and eukaryotic translation initiation factor 5A-1 (eIF5A1). Of these seven proteins, the level of eIF5A1 was up-regulated, whereas the remaining proteins were down-regulated. In conclusion, oleamide has antidepressant-like properties in the CMS rat model. The identification of proteins altered by CMS and oleamide treatment provides support for targeting these proteins in the development of novel therapies for depression. Copyright © 2015 Elsevier Inc. All rights reserved.
Storage element performance optimization for CMS analysis jobs
NASA Astrophysics Data System (ADS)
Behrmann, G.; Dahlblom, J.; Guldmyr, J.; Happonen, K.; Lindén, T.
2012-12-01
Tier-2 computing sites in the Worldwide Large Hadron Collider Computing Grid (WLCG) host CPU-resources (Compute Element, CE) and storage resources (Storage Element, SE). The vast amount of data that needs to processed from the Large Hadron Collider (LHC) experiments requires good and efficient use of the available resources. Having a good CPU efficiency for the end users analysis jobs requires that the performance of the storage system is able to scale with I/O requests from hundreds or even thousands of simultaneous jobs. In this presentation we report on the work on improving the SE performance at the Helsinki Institute of Physics (HIP) Tier-2 used for the Compact Muon Experiment (CMS) at the LHC. Statistics from CMS grid jobs are collected and stored in the CMS Dashboard for further analysis, which allows for easy performance monitoring by the sites and by the CMS collaboration. As part of the monitoring framework CMS uses the JobRobot which sends every four hours 100 analysis jobs to each site. CMS also uses the HammerCloud tool for site monitoring and stress testing and it has replaced the JobRobot. The performance of the analysis workflow submitted with JobRobot or HammerCloud can be used to track the performance due to site configuration changes, since the analysis workflow is kept the same for all sites and for months in time. The CPU efficiency of the JobRobot jobs at HIP was increased approximately by 50 % to more than 90 %, by tuning the SE and by improvements in the CMSSW and dCache software. The performance of the CMS analysis jobs improved significantly too. Similar work has been done on other CMS Tier-sites, since on average the CPU efficiency for CMSSW jobs has increased during 2011. Better monitoring of the SE allows faster detection of problems, so that the performance level can be kept high. The next storage upgrade at HIP consists of SAS disk enclosures which can be stress tested on demand with HammerCloud workflows, to make sure that the I/O-performance is good.
Application of LANDSAT system for improving methodology for inventory and classification of wetlands
NASA Technical Reports Server (NTRS)
Gilmer, D. S. (Principal Investigator)
1976-01-01
The author has identified the following significant results. A newly developed software system for generating statistics on surface water features was tested using LANDSAT data acquired previous to 1975. This software test provided a satisfactory evaluation of the system and also allowed expansion of data base on prairie water features. The software system recognizes water on the basis of a classification algorithm. This classification is accomplished by level thresholding a single near infrared data channel. After each pixel is classified as water or nonwater, the software system then recognizes ponds or lakes as sets of contiguous pixels or as single isolated pixels in the case of very small ponds. Pixels are considered to be contiguous if they are adjacent between successive scan lines. After delineating each water feature, the software system then assigns the feature a position based upon a geographic grid system and calculates the feature's planimetric area, its perimeter, and a parameter known as the shape factor.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-29
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services (CMS) [CMS-2382-N... Challenge AGENCY: Centers for Medicare & Medicaid Services (CMS), HHS. ACTION: Notice. SUMMARY: The Centers for Medicare & Medicaid Services (CMS), is announcing the launch of the ``CMS Provider Screening...
A comparison between physicians and computer algorithms for form CMS-2728 data reporting.
Malas, Mohammed Said; Wish, Jay; Moorthi, Ranjani; Grannis, Shaun; Dexter, Paul; Duke, Jon; Moe, Sharon
2017-01-01
CMS-2728 form (Medical Evidence Report) assesses 23 comorbidities chosen to reflect poor outcomes and increased mortality risk. Previous studies questioned the validity of physician reporting on forms CMS-2728. We hypothesize that reporting of comorbidities by computer algorithms identifies more comorbidities than physician completion, and, therefore, is more reflective of underlying disease burden. We collected data from CMS-2728 forms for all 296 patients who had incident ESRD diagnosis and received chronic dialysis from 2005 through 2014 at Indiana University outpatient dialysis centers. We analyzed patients' data from electronic medical records systems that collated information from multiple health care sources. Previously utilized algorithms or natural language processing was used to extract data on 10 comorbidities for a period of up to 10 years prior to ESRD incidence. These algorithms incorporate billing codes, prescriptions, and other relevant elements. We compared the presence or unchecked status of these comorbidities on the forms to the presence or absence according to the algorithms. Computer algorithms had higher reporting of comorbidities compared to forms completion by physicians. This remained true when decreasing data span to one year and using only a single health center source. The algorithms determination was well accepted by a physician panel. Importantly, algorithms use significantly increased the expected deaths and lowered the standardized mortality ratios. Using computer algorithms showed superior identification of comorbidities for form CMS-2728 and altered standardized mortality ratios. Adapting similar algorithms in available EMR systems may offer more thorough evaluation of comorbidities and improve quality reporting. © 2016 International Society for Hemodialysis.
Nozaki, Yumiko; Honda, Yayoi; Watanabe, Hitoshi; Saiki, Shota; Koyabu, Kiyotaka; Itoh, Tetsuji; Nagasawa, Chiho; Nakamori, Chiaki; Nakayama, Chiaki; Iwasaki, Hiroshi; Suzuki, Shinobu; Tanaka, Kohji; Takahashi, Etsushi; Miyamoto, Kaori; Morimura, Kaoru; Yamanishi, Atsuhiro; Endo, Hiroko; Shinozaki, Junko; Nogawa, Hisashi; Shinozawa, Tadahiro; Saito, Fumiyo; Kunimatsu, Takeshi
2017-08-01
With the aim of reconsidering ICH S7B and E14 guidelines, a new in vitro assay system has been subjected to worldwide validation to establish a better prediction platform for potential drug-induced QT prolongation and the consequent TdP in clinical practice. In Japan, CSAHi HEART team has been working on hiPS-CMs in the MEA (hiPS-CMs/MEA) under a standardized protocol and found no inter-facility or lot-to-lot variability for proarrhythmic risk assessment of 7 reference compounds. In this study, we evaluated the responses of hiPS-CMs/MEA to another 31 reference compounds associated with cardiac toxicities, and gene expression to further clarify the electrophysiological characteristics over the course of culture period. The hiPS-CMs/MEA assay accurately predicted reference compounds potential for arrhythmogenesis, and yielded results that showed better correlation with target concentrations of QTc prolongation or TdP in clinical setting than other current in vitro and in vivo assays. Gene expression analyses revealed consistent profiles in all samples within and among the testing facilities. This report would provide CiPA with informative guidance on the use of the hiPS-CMs/MEA assay, and promote the establishment of a new paradigm, beyond conventional in vitro and in vivo assays for cardiac safety assessment of new drugs. Copyright © 2017 Elsevier Inc. All rights reserved.
Log polar image sensor in CMOS technology
NASA Astrophysics Data System (ADS)
Scheffer, Danny; Dierickx, Bart; Pardo, Fernando; Vlummens, Jan; Meynants, Guy; Hermans, Lou
1996-08-01
We report on the design, design issues, fabrication and performance of a log-polar CMOS image sensor. The sensor is developed for the use in a videophone system for deaf and hearing impaired people, who are not capable of communicating through a 'normal' telephone. The system allows 15 detailed images per second to be transmitted over existing telephone lines. This framerate is sufficient for conversations by means of sign language or lip reading. The pixel array of the sensor consists of 76 concentric circles with (up to) 128 pixels per circle, in total 8013 pixels. The interior pixels have a pitch of 14 micrometers, up to 250 micrometers at the border. The 8013-pixels image is mapped (log-polar transformation) in a X-Y addressable 76 by 128 array.
Xie, Binghan; Gong, Weijia; Ding, An; Yu, Huarong; Qu, Fangshu; Tang, Xiaobin; Yan, Zhongsen; Li, Guibai; Liang, Heng
2017-10-01
Microbial fuel cell (MFC) is a sustainable technology to treat cattle manure slurry (CMS) for converting chemical energy to bioelectricity. In this work, two types of allochthonous inoculum including activated sludge (AS) and domestic sewage (DS) were added into the MFC systems to enhance anode biofilm formation and electricity generation. Results indicated that MFCs (AS + CMS) obtained the maximum electricity output with voltage approaching 577 ± 7 mV (~ 196 h), followed by MFCs (DS + CMS) (520 ± 21 mV, ~ 236 h) and then MFCs with autochthonous inoculum (429 ± 62 mV, ~ 263.5 h). Though the raw cattle manure slurry (RCMS) could facilitate electricity production in MFCs, the addition of allochthonous inoculum (AS/DS) significantly reduced the startup time and enhanced the output voltage. Moreover, the maximum power (1.259 ± 0.015 W/m 2 ) and the highest COD removal (84.72 ± 0.48%) were obtained in MFCs (AS + CMS). With regard to microbial community, Illumina HiSeq of the 16S rRNA gene was employed in this work and the exoelectrogens (Geobacter and Shewanella) were identified as the dominant members on all anode biofilms in MFCs. For anode microbial diversity, the MFCs (AS + CMS) outperformed MFCs (DS + CMS) and MFCs (RCMS), allowing the occurrence of the fermentative (e.g., Bacteroides) and nitrogen fixation bacteria (e.g., Azoarcus and Sterolibacterium) which enabled the efficient degradation of the slurry. This study provided a feasible strategy to analyze the anode biofilm formation by adding allochthonous inoculum and some implications for quick startup of MFC reactors for CMS treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nozaki, Yumiko, E-mail: yumiko-nozaki@ds-pharma.co.jp; Honda, Yayoi, E-mail: yayoi-honda@ds-pharma.co.jp; Tsujimoto, Shinji, E-mail: shinji-tsujimoto@ds-pharma.co.jp
2014-07-01
Field potential duration (FPD) in human-induced pluripotent stem cell-derived cardiomyocytes (hiPS-CMs), which can express QT interval in an electrocardiogram, is reported to be a useful tool to predict K{sup +} channel and Ca{sup 2+} channel blocker effects on QT interval. However, there is no report showing that this technique can be used to predict multichannel blocker potential for QT prolongation. The aim of this study is to show that FPD from MEA (Multielectrode array) of hiPS-CMs can detect QT prolongation induced by multichannel blockers. hiPS-CMs were seeded onto MEA and FPD was measured for 2 min every 10 min formore » 30 min after drug exposure for the vehicle and each drug concentration. I{sub Kr} and I{sub Ks} blockers concentration-dependently prolonged corrected FPD (FPDc), whereas Ca{sup 2+} channel blockers concentration-dependently shortened FPDc. Also, the multichannel blockers Amiodarone, Paroxetine, Terfenadine and Citalopram prolonged FPDc in a concentration dependent manner. Finally, the I{sub Kr} blockers, Terfenadine and Citalopram, which are reported to cause Torsade de Pointes (TdP) in clinical practice, produced early afterdepolarization (EAD). hiPS-CMs using MEA system and FPDc can predict the effects of drug candidates on QT interval. This study also shows that this assay can help detect EAD for drugs with TdP potential. - Highlights: • We focused on hiPS-CMs to replace in vitro assays in preclinical screening studies. • hiPS-CMs FPD is useful as an indicator to predict drug potential for QT prolongation. • MEA assay can help detect EAD for drugs with TdP potentials. • MEA assay in hiPS-CMs is useful for accurately predicting drug TdP risk in humans.« less
Precise color images a high-speed color video camera system with three intensified sensors
NASA Astrophysics Data System (ADS)
Oki, Sachio; Yamakawa, Masafumi; Gohda, Susumu; Etoh, Takeharu G.
1999-06-01
High speed imaging systems have been used in a large field of science and engineering. Although the high speed camera systems have been improved to high performance, most of their applications are only to get high speed motion pictures. However, in some fields of science and technology, it is useful to get some other information, such as temperature of combustion flame, thermal plasma and molten materials. Recent digital high speed video imaging technology should be able to get such information from those objects. For this purpose, we have already developed a high speed video camera system with three-intensified-sensors and cubic prism image splitter. The maximum frame rate is 40,500 pps (picture per second) at 64 X 64 pixels and 4,500 pps at 256 X 256 pixels with 256 (8 bit) intensity resolution for each pixel. The camera system can store more than 1,000 pictures continuously in solid state memory. In order to get the precise color images from this camera system, we need to develop a digital technique, which consists of a computer program and ancillary instruments, to adjust displacement of images taken from two or three image sensors and to calibrate relationship between incident light intensity and corresponding digital output signals. In this paper, the digital technique for pixel-based displacement adjustment are proposed. Although the displacement of the corresponding circle was more than 8 pixels in original image, the displacement was adjusted within 0.2 pixels at most by this method.
Method for fabricating pixelated silicon device cells
Nielson, Gregory N.; Okandan, Murat; Cruz-Campa, Jose Luis; Nelson, Jeffrey S.; Anderson, Benjamin John
2015-08-18
A method, apparatus and system for flexible, ultra-thin, and high efficiency pixelated silicon or other semiconductor photovoltaic solar cell array fabrication is disclosed. A structure and method of creation for a pixelated silicon or other semiconductor photovoltaic solar cell array with interconnects is described using a manufacturing method that is simplified compared to previous versions of pixelated silicon photovoltaic cells that require more microfabrication steps.
Novel spectral imaging system combining spectroscopy with imaging applications for biology
NASA Astrophysics Data System (ADS)
Malik, Zvi; Cabib, Dario; Buckwald, Robert A.; Garini, Yuval; Soenksen, Dirk G.
1995-02-01
A novel analytical spectral-imaging system and its results in the examination of biological specimens are presented. The SpectraCube 1000 system measures the transmission, absorbance, or fluorescence spectra of images studied by light microscopy. The system is based on an interferometer combined with a CCD camera, enabling measurement of the interferogram for each pixel constructing the image. Fourier transformation of the interferograms derives pixel by pixel spectra for 170 X 170 pixels of the image. A special `similarity mapping' program has been developed, enabling comparisons of spectral algorithms of all the spatial and spectral information measured by the system in the image. By comparing the spectrum of each pixel in the specimen with a selected reference spectrum (similarity mapping), there is a depiction of the spatial distribution of macromolecules possessing the characteristics of the reference spectrum. The system has been applied to analyses of bone marrow blood cells as well as fluorescent specimens, and has revealed information which could not be unveiled by other techniques. Similarity mapping has enabled visualization of fine details of chromatin packing in the nucleus of cells and other cytoplasmic compartments. Fluorescence analysis by the system has enabled the determination of porphyrin concentrations and distribution in cytoplasmic organelles of living cells.
Mathematical values in the processing of Chinese numeral classifiers and measure words.
Her, One-Soon; Chen, Ying-Chun; Yen, Nai-Shing
2017-01-01
A numeral classifier is required between a numeral and a noun in Chinese, which comes in two varieties, sortal classifer (C) and measural classifier (M), also known as 'classifier' and 'measure word', respectively. Cs categorize objects based on semantic attributes and Cs and Ms both denote quantity in terms of mathematical values. The aim of this study was to conduct a psycholinguistic experiment to examine whether participants process C/Ms based on their mathematical values with a semantic distance comparison task, where participants judged which of the two C/M phrases was semantically closer to the target C/M. Results showed that participants performed more accurately and faster for C/Ms with fixed values than the ones with variable values. These results demonstrated that mathematical values do play an important role in the processing of C/Ms. This study may thus shed light on the influence of the linguistic system of C/Ms on magnitude cognition.
Verification and Validation of the Coastal Modeling System. Report 2: CMS-Wave
2011-12-01
Figure 44. Offshore bathymetry showing NDBC and CDIP buoy locations. ........................................ 70 Figure 45. CMS-Wave modeling domain...the four measurement stations. During the same time intervals, offshore wave information was available from a Coastal Data Information Program ( CDIP ...were conducted with a grid of 236 × 398 cells with variable cell spacing of 30 to 200 m (see Figure 28). Directional wave spectra from CDIP 036 served
Hydrodynamic Modeling for Channel and Shoreline Stabilization at Rhodes Point, Smith Island, MD
2016-11-01
shorelines. Both Alternatives included the same revetment structure for protecting the south shoreline. The Coastal Modeling System (CMS, including CMS...ER D C/ CH L TR -1 6- 17 Coastal Inlets Research Program Hydrodynamic Modeling for Channel and Shoreline Stabilization at Rhodes Point...acwc.sdp.sirsi.net/client/default. Coastal Inlets Research Program ERDC/CHL TR-16-17 November 2016 Hydrodynamic Modeling for Channel and Shoreline
Evaluation of PET Imaging Resolution Using 350 mu{m} Pixelated CZT as a VP-PET Insert Detector
NASA Astrophysics Data System (ADS)
Yin, Yongzhi; Chen, Ximeng; Li, Chongzheng; Wu, Heyu; Komarov, Sergey; Guo, Qingzhen; Krawczynski, Henric; Meng, Ling-Jian; Tai, Yuan-Chuan
2014-02-01
A cadmium-zinc-telluride (CZT) detector with 350 μm pitch pixels was studied in high-resolution positron emission tomography (PET) imaging applications. The PET imaging system was based on coincidence detection between a CZT detector and a lutetium oxyorthosilicate (LSO)-based Inveon PET detector in virtual-pinhole PET geometry. The LSO detector is a 20 ×20 array, with 1.6 mm pitches, and 10 mm thickness. The CZT detector uses ac 20 ×20 ×5 mm substrate, with 350 μm pitch pixelated anodes and a coplanar cathode. A NEMA NU4 Na-22 point source of 250 μm in diameter was imaged by this system. Experiments show that the image resolution of single-pixel photopeak events was 590 μm FWHM while the image resolution of double-pixel photopeak events was 640 μm FWHM. The inclusion of double-pixel full-energy events increased the sensitivity of the imaging system. To validate the imaging experiment, we conducted a Monte Carlo (MC) simulation for the same PET system in Geant4 Application for Emission Tomography. We defined LSO detectors as a scanner ring and 350 μm pixelated CZT detectors as an insert ring. GATE simulated coincidence data were sorted into an insert-scanner sinogram and reconstructed. The image resolution of MC-simulated data (which did not factor in positron range and acolinearity effect) was 460 μm at FWHM for single-pixel events. The image resolutions of experimental data, MC simulated data, and theoretical calculation are all close to 500 μm FWHM when the proposed 350 μm pixelated CZT detector is used as a PET insert. The interpolation algorithm for the charge sharing events was also investigated. The PET image that was reconstructed using the interpolation algorithm shows improved image resolution compared with the image resolution without interpolation algorithm.
First-principles study of spin-transfer torque in Co{sub 2}MnSi/Al/Co{sub 2}MnSi spin-valve
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Ling, E-mail: lingtang@zjut.edu.cn; Yang, Zejin, E-mail: zejinyang@zjut.edu.cn
The spin-transfer torque (STT) in Co{sub 2}MnSi(CMS)/Al/Co{sub 2}MnSi spin-valve system with and without interfacial disorder is studied by a first-principles noncollinear wave-function-matching method. It is shown that in the case of clean interface the angular dependence of STT for CoCo/Al (the asymmetry parameter Λ≈4.5) is more skewed than that for MnSi/Al (Λ≈2.9), which suggests the clean CoCo/Al architecture is much more efficient for the application on radio frequency oscillation. We also find that even with interfacial disorder the spin-valve of half-metallic CMS still has a relatively large parameter Λ compared to that of conventional ferromagnet. In addition, for clean interfacemore » the in-plane torkance of MnSi/Al is about twice as large as that of CoCo/Al. However, as long as the degree of interfacial disorder is sufficiently large, the CoCo/Al and MnSi/Al will show approximately the same magnitude of in-plane torkance. Furthermore, our results demonstrate that CMS/Al/CMS system has very high efficiency of STT to switch the magnetic layer of spin-valve.« less
Science on Drupal: An evaluation of CMS Technologies
NASA Astrophysics Data System (ADS)
Vinay, S.; Gonzalez, A.; Pinto, A.; Pascuzzi, F.; Gerard, A.
2011-12-01
We conducted an extensive evaluation of various Content Management System (CMS) technologies for implementing different websites supporting interdisciplinary science data and information. We chose two products, Drupal and Bluenog/Hippo CMS, to meet our specific needs and requirements. Drupal is an open source product that is quick and easy to setup and use. It is a very mature, stable, and widely used product. It has rich functionality supported by a large and active user base and developer community. There are many plugins available that provide additional features for managing citations, map gallery, semantic search, digital repositories (fedora), scientific workflows, collaborative authoring, social networking, and other functions. All of these work very well within the Drupal framework if minimal customization is needed. We have successfully implemented Drupal for multiple projects such as: 1) the Haiti Regeneration Initiative (http://haitiregeneration.org/); 2) the Consortium on Climate Risk in the Urban Northeast (http://beta.ccrun.org/); and 3) the Africa Soils Information Service (http://africasoils.net/). We are also developing two other websites, the Côte Sud Initiative (CSI) and Emerging Infectious Diseases, using Drupal. We are testing the Drupal multi-site install for managing different websites with one install to streamline the maintenance. In addition, paid support and consultancy for Drupal website development are available at affordable prices. All of these features make Drupal very attractive for implementing state-of-the-art scientific websites that do not have complex requirements. One of our major websites, the NASA Socioeconomic Data and Applications Center (SEDAC), has a very complex set of requirements. It has to easily re-purpose content across multiple web pages and sites with different presentations. It has to serve the content via REST or similar standard interfaces so that external client applications can access content in the CMS repository. This means the content repository and structure should be completely separated from the content presentation and site structure. In addition to the CMS repository, the front-end website has to be able to consume, integrate, and display diverse content flexibly from multiple back-end systems, including custom and legacy systems, such as Oracle, Geoserver, Flickr, Fedora, and other web services. We needed the ability to customize the workflow to author, edit, approve, and publish content based on different content types and project requirements. In addition, we required the ability to use the existing active directory for user management with support for roles and groups and permissions using Access Control List (ACL) model. The ability to version and lock content was also important. We determined that most of these capabilities are difficult to implement with Drupal and needed significant customization. The Bluenog eCMS (enterprise CMS) product satisfied most of these requirements. Bluenog eCMS is based on an open source product called Hippo with customizations and support provided by the vendor Bluenog. Our newly redesigned and recently released SEDAC website, http://sedac.ciesin.columbia.edu, is implemented using Bluenog eCMS. Other products we evaluated include WebLogic portal, Magnolia, Liferay portal, and Alfresco.
Padula, William V; Gibbons, Robert D; Valuck, Robert J; Makic, Mary B F; Mishra, Manish K; Pronovost, Peter J; Meltzer, David O
2016-05-01
In 2008, the Centers for Medicare and Medicaid Services (CMS) established nonpayment policies resulting from costliness of hospital-acquired pressure ulcers (HAPUs) to hospitals. This prompted hospitals to adopt quality improvement (QI) interventions that increase use of evidence-based practices (EBPs) for HAPU prevention. To evaluate the longitudinal impact of CMS policy and QI adoption on HAPU rates. We characterized longitudinal adoption of 25 QI interventions that support EBPs through hospital leadership, staff, information technology, and performance and improvement. Quarterly counts of HAPU incidence and inpatient characteristics were collected from 55 University HealthSystem Consortium hospitals between 2007 and 2012. Mixed-effects regression models tested the longitudinal association of CMS policy, HAPU coding, and QI on HAPU rates. The models assumed level-2 random intercepts and random effects for CMS policy and EBP implementation to account for between-hospital variability in HAPU incidence. Controlling for all 25 QI interventions, specific updates to EBPs for HAPU prevention had a significant, though modest reduction on HAPU rates (-1.86 cases/quarter; P=0.002) and the effect of CMS nonpayment policy on HAPU prevention was much greater (-11.32 cases/quarter; P<0.001). HAPU rates were significantly lower after changes in CMS reimbursement. Reductions are associated with hospital-wide implementation of EBPs for HAPU prevention. Given that administrative data were used, it remains unknown whether these improvements were due to changes in coding or improved quality of care.
Sustained release effects of berberine-loaded chitosan microspheres on in vitro chondrocyte culture.
Zhou, Yan; Liu, Shiqing; Ming, Jianghua; Li, Yaming; Deng, Ming; He, Bin
2017-10-01
The low bioavailability and short biological half-life of berberine chloride (BBR) negatively affect the protective role of this compound against osteoarthritis (OA). The present study was performed to evaluate the effectiveness of sustained BBR release system. Novel BBR-loaded chitosan microspheres (BBR-loaded CMs) were successfully synthesized using an ionic cross-linking method for sustained release. The basic characteristics of the prepared microspheres were subsequently evaluated by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD) techniques, encapsulation efficiency (EE), and in vitro release experiments. BBR-loaded CMs displayed spherical forms to encapsulate a considerable quantity of BBR (100.8 ± 2.7 mg/g); these microspheres also exhibited an ideal releasing profile. The FT-IR spectra and XRD results revealed that BBR-loaded CMs were successfully synthesized via electrostatic interaction. In vitro experiments further showed that BBR-loaded CMs significantly inhibited sodium nitroprusside (SNP)-stimulated chondrocyte apoptosis as well as cytoskeletal remodeling, and led to increasing mitochondrial membrane potential and maintaining the nuclear morphology. BBR-loaded CMs exerted markedly higher anti-apoptotic activity in the treatment of OA, and markedly inhibited the protein expression levels of caspase-3, a disintegrin, and metalloproteinase with thrombospondin motifs (ADAMTS)-5 and matrix metalloproteinase (MMP)-13 induced by SNP in rat articular chondrocytes, compared with free BBR at equivalent concentration. Therefore, novel BBR-loaded CMs may offer potential for application in the treatment of OA.
NASA Astrophysics Data System (ADS)
Battilana, C.
2017-01-01
The CMS muon system has played a key role for many physics results obtained from the LHC Run-1 and Run-2 data. During the Long Shutdown (2013-2014), as well as during the last year-end technical stop (2015-2016), significant consolidation and upgrades have been carried out on the muon detectors and on the L1 muon trigger. The algorithms for muon reconstruction and identification have also been improved for both the High-Level Trigger and the offline reconstruction. Results of the performance of muon detectors, reconstruction and trigger, obtained using data collected at 13 TeV centre-of-mass energy during the 2015 and 2016 LHC runs, will be presented. Comparison of simulation with experimental data will also be discussed where relevant. The system's state of the art performance will be shown, and the improvements foreseen to achieve excellent overall quality of muon reconstruction in CMS, in the conditions expected during the high-luminosity phase of Run-2, will be described.
File-based data flow in the CMS Filter Farm
NASA Astrophysics Data System (ADS)
Andre, J.-M.; Andronidis, A.; Bawej, T.; Behrens, U.; Branson, J.; Chaze, O.; Cittolin, S.; Darlea, G.-L.; Deldicque, C.; Dobson, M.; Dupont, A.; Erhan, S.; Gigi, D.; Glege, F.; Gomez-Ceballos, G.; Hegeman, J.; Holzner, A.; Jimenez-Estupiñán, R.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; Morovic, S.; Nunez-Barranco-Fernandez, C.; O'Dell, V.; Orsini, L.; Paus, C.; Petrucci, A.; Pieri, M.; Racz, A.; Roberts, P.; Sakulin, H.; Schwick, C.; Stieger, B.; Sumorok, K.; Veverka, J.; Zaza, S.; Zejdl, P.
2015-12-01
During the LHC Long Shutdown 1, the CMS Data Acquisition system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and prepare the ground for future upgrades of the detector front-ends. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. This approach provides additional decoupling between the HLT algorithms and the input and output data flow. All the metadata needed for bookkeeping of the data flow and the HLT process lifetimes are also generated in the form of small “documents” using the JSON encoding, by either services in the flow of the HLT execution (for rates etc.) or watchdog processes. These “files” can remain memory-resident or be written to disk if they are to be used in another part of the system (e.g. for aggregation of output data). We discuss how this redesign improves the robustness and flexibility of the CMS DAQ and the performance of the system currently being commissioned for the LHC Run 2.
Survey of on-road image projection with pixel light systems
NASA Astrophysics Data System (ADS)
Rizvi, Sadiq; Knöchelmann, Marvin; Ley, Peer-Phillip; Lachmayer, Roland
2017-12-01
HID, LED and laser-based high resolution automotive headlamps, as of late known as `pixel light systems', are at the forefront of the developing technologies paving the way for autonomous driving. In addition to light distribution capabilities that outperform Adaptive Front Lighting and Matrix Beam systems, pixel light systems provide the possibility of image projection directly onto the street. The underlying objective is to improve the driving experience, in any given scenario, in terms of safety, comfort and interaction for all road users. The focus of this work is to conduct a short survey on this state-of-the-art image projection functionality. A holistic research regarding the image projection functionality can be divided into three major categories: scenario selection, technological development and evaluation design. Consequently, the work presented in this paper is divided into three short studies. Section 1 provides a brief introduction to pixel light systems and a justification for the approach adopted for this study. Section 2 deals with the selection of scenarios (and driving maneuvers) where image projection can play a critical role. Section 3 discusses high power LED and LED array based prototypes that are currently under development. Section 4 demonstrates results from an experiment conducted to evaluate the illuminance of an image space projected using a pixel light system prototype developed at the Institute of Product Development (IPeG). Findings from this work can help to identify and advance future research work relating to: further development of pixel light systems, scenario planning, examination of optimal light sources, behavioral response studies etc.
Tracking at High Level Trigger in CMS
NASA Astrophysics Data System (ADS)
Tosi, M.
2016-04-01
The trigger systems of the LHC detectors play a crucial role in determining the physics capabilities of experiments. A reduction of several orders of magnitude of the event rate is needed to reach values compatible with detector readout, offline storage and analysis capability. The CMS experiment has been designed with a two-level trigger system: the Level-1 Trigger (L1T), implemented on custom-designed electronics, and the High Level Trigger (HLT), a streamlined version of the CMS offline reconstruction software running on a computer farm. A software trigger system requires a trade-off between the complexity of the algorithms, the sustainable output rate, and the selection efficiency. With the computing power available during the 2012 data taking the maximum reconstruction time at HLT was about 200 ms per event, at the nominal L1T rate of 100 kHz. Track reconstruction algorithms are widely used in the HLT, for the reconstruction of the physics objects as well as in the identification of b-jets and lepton isolation. Reconstructed tracks are also used to distinguish the primary vertex, which identifies the hard interaction process, from the pileup ones. This task is particularly important in the LHC environment given the large number of interactions per bunch crossing: on average 25 in 2012, and expected to be around 40 in Run II. We will present the performance of HLT tracking algorithms, discussing its impact on CMS physics program, as well as new developments done towards the next data taking in 2015.
Adaptive variable-length coding for efficient compression of spacecraft television data.
NASA Technical Reports Server (NTRS)
Rice, R. F.; Plaunt, J. R.
1971-01-01
An adaptive variable length coding system is presented. Although developed primarily for the proposed Grand Tour missions, many features of this system clearly indicate a much wider applicability. Using sample to sample prediction, the coding system produces output rates within 0.25 bit/picture element (pixel) of the one-dimensional difference entropy for entropy values ranging from 0 to 8 bit/pixel. This is accomplished without the necessity of storing any code words. Performance improvements of 0.5 bit/pixel can be simply achieved by utilizing previous line correlation. A Basic Compressor, using concatenated codes, adapts to rapid changes in source statistics by automatically selecting one of three codes to use for each block of 21 pixels. The system adapts to less frequent, but more dramatic, changes in source statistics by adjusting the mode in which the Basic Compressor operates on a line-to-line basis. Furthermore, the compression system is independent of the quantization requirements of the pulse-code modulation system.
NASA Astrophysics Data System (ADS)
Schuster, J.
2018-02-01
Military requirements demand both single and dual-color infrared (IR) imaging systems with both high resolution and sharp contrast. To quantify the performance of these imaging systems, a key measure of performance, the modulation transfer function (MTF), describes how well an optical system reproduces an objects contrast in the image plane at different spatial frequencies. At the center of an IR imaging system is the focal plane array (FPA). IR FPAs are hybrid structures consisting of a semiconductor detector pixel array, typically fabricated from HgCdTe, InGaAs or III-V superlattice materials, hybridized with heat/pressure to a silicon read-out integrated circuit (ROIC) with indium bumps on each pixel providing the mechanical and electrical connection. Due to the growing sophistication of the pixel arrays in these FPAs, sophisticated modeling techniques are required to predict, understand, and benchmark the pixel array MTF that contributes to the total imaging system MTF. To model the pixel array MTF, computationally exhaustive 2D and 3D numerical simulation approaches are required to correctly account for complex architectures and effects such as lateral diffusion from the pixel corners. It is paramount to accurately model the lateral di_usion (pixel crosstalk) as it can become the dominant mechanism limiting the detector MTF if not properly mitigated. Once the detector MTF has been simulated, it is directly decomposed into its constituent contributions to reveal exactly what is limiting the total detector MTF, providing a path for optimization. An overview of the MTF will be given and the simulation approach will be discussed in detail, along with how different simulation parameters effect the MTF calculation. Finally, MTF optimization strategies (crosstalk mitigation) will be discussed.
Reznik, Nikita; Komljenovic, Philip T; Germann, Stephen; Rowlands, John A
2008-03-01
A new amorphous selenium (a-Se) digital radiography detector is introduced. The proposed detector generates a charge image in the a-Se layer in a conventional manner, which is stored on electrode pixels at the surface of the a-Se layer. A novel method, called photoconductively activated switch (PAS), is used to read out the latent x-ray charge image. The PAS readout method uses lateral photoconduction at the a-Se surface which is a revolutionary modification of the bulk photoinduced discharge (PID) methods. The PAS method addresses and eliminates the fundamental weaknesses of the PID methods--long readout times and high readout noise--while maintaining the structural simplicity and high resolution for which PID optical readout systems are noted. The photoconduction properties of the a-Se surface were investigated and the geometrical design for the electrode pixels for a PAS radiography system was determined. This design was implemented in a single pixel PAS evaluation system. The results show that the PAS x-ray induced output charge signal was reproducible and depended linearly on the x-ray exposure in the diagnostic exposure range. Furthermore, the readout was reasonably rapid (10 ms for pixel discharge). The proposed detector allows readout of half a pixel row at a time (odd pixels followed by even pixels), thus permitting the readout of a complete image in 30 s for a 40 cm x 40 cm detector with the potential of reducing that time by using greater readout light intensity. This demonstrates that a-Se based x-ray detectors using photoconductively activated switches could form a basis for a practical integrated digital radiography system.
Web-based monitoring tools for Resistive Plate Chambers in the CMS experiment at CERN
NASA Astrophysics Data System (ADS)
Kim, M. S.; Ban, Y.; Cai, J.; Li, Q.; Liu, S.; Qian, S.; Wang, D.; Xu, Z.; Zhang, F.; Choi, Y.; Kim, D.; Goh, J.; Choi, S.; Hong, B.; Kang, J. W.; Kang, M.; Kwon, J. H.; Lee, K. S.; Lee, S. K.; Park, S. K.; Pant, L. M.; Mohanty, A. K.; Chudasama, R.; Singh, J. B.; Bhatnagar, V.; Mehta, A.; Kumar, R.; Cauwenbergh, S.; Costantini, S.; Cimmino, A.; Crucy, S.; Fagot, A.; Garcia, G.; Ocampo, A.; Poyraz, D.; Salva, S.; Thyssen, F.; Tytgat, M.; Zaganidis, N.; Doninck, W. V.; Cabrera, A.; Chaparro, L.; Gomez, J. P.; Gomez, B.; Sanabria, J. C.; Avila, C.; Ahmad, A.; Muhammad, S.; Shoaib, M.; Hoorani, H.; Awan, I.; Ali, I.; Ahmed, W.; Asghar, M. I.; Shahzad, H.; Sayed, A.; Ibrahim, A.; Aly, S.; Assran, Y.; Radi, A.; Elkafrawy, T.; Sharma, A.; Colafranceschi, S.; Abbrescia, M.; Calabria, C.; Colaleo, A.; Iaselli, G.; Loddo, F.; Maggi, M.; Nuzzo, S.; Pugliese, G.; Radogna, R.; Venditti, R.; Verwilligen, P.; Benussi, L.; Bianco, S.; Piccolo, D.; Paolucci, P.; Buontempo, S.; Cavallo, N.; Merola, M.; Fabozzi, F.; Iorio, O. M.; Braghieri, A.; Montagna, P.; Riccardi, C.; Salvini, P.; Vitulo, P.; Vai, I.; Magnani, A.; Dimitrov, A.; Litov, L.; Pavlov, B.; Petkov, P.; Aleksandrov, A.; Genchev, V.; Iaydjiev, P.; Rodozov, M.; Sultanov, G.; Vutova, M.; Stoykova, S.; Hadjiiska, R.; Ibargüen, H. S.; Morales, M. I. P.; Bernardino, S. C.; Bagaturia, I.; Tsamalaidze, Z.; Crotty, I.
2014-10-01
The Resistive Plate Chambers (RPC) are used in the CMS experiment at the trigger level and also in the standard offline muon reconstruction. In order to guarantee the quality of the data collected and to monitor online the detector performance, a set of tools has been developed in CMS which is heavily used in the RPC system. The Web-based monitoring (WBM) is a set of java servlets that allows users to check the performance of the hardware during data taking, providing distributions and history plots of all the parameters. The functionalities of the RPC WBM monitoring tools are presented along with studies of the detector performance as a function of growing luminosity and environmental conditions that are tracked over time.
23 CFR 970.214 - Federal lands congestion management system (CMS).
Code of Federal Regulations, 2012 CFR
2012-04-01
... LANDS HIGHWAYS NATIONAL PARK SERVICE MANAGEMENT SYSTEMS National Park Service Management Systems § 970... value (protection/rejuvenation of resources, improved visitor experience) to the park and adjacent...
23 CFR 970.214 - Federal lands congestion management system (CMS).
Code of Federal Regulations, 2013 CFR
2013-04-01
... LANDS HIGHWAYS NATIONAL PARK SERVICE MANAGEMENT SYSTEMS National Park Service Management Systems § 970... value (protection/rejuvenation of resources, improved visitor experience) to the park and adjacent...
Fast Fiber-Coupled Imaging Devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brockington, Samuel; Case, Andrew; Witherspoon, Franklin Douglas
HyperV Technologies Corp. has successfully designed, built and experimentally demonstrated a full scale 1024 pixel 100 MegaFrames/s fiber coupled camera with 12 or 14 bits, and record lengths of 32K frames, exceeding our original performance objectives. This high-pixel-count, fiber optically-coupled, imaging diagnostic can be used for investigating fast, bright plasma events. In Phase 1 of this effort, a 100 pixel fiber-coupled fast streak camera for imaging plasma jet profiles was constructed and successfully demonstrated. The resulting response from outside plasma physics researchers emphasized development of increased pixel performance as a higher priority over increasing pixel count. In this Phase 2more » effort, HyperV therefore focused on increasing the sample rate and bit-depth of the photodiode pixel designed in Phase 1, while still maintaining a long record length and holding the cost per channel to levels which allowed up to 1024 pixels to be constructed. Cost per channel was 53.31 dollars, very close to our original target of $50 per channel. The system consists of an imaging "camera head" coupled to a photodiode bank with an array of optical fibers. The output of these fast photodiodes is then digitized at 100 Megaframes per second and stored in record lengths of 32,768 samples with bit depths of 12 to 14 bits per pixel. Longer record lengths are possible with additional memory. A prototype imaging system with up to 1024 pixels was designed and constructed and used to successfully take movies of very fast moving plasma jets as a demonstration of the camera performance capabilities. Some faulty electrical components on the 64 circuit boards resulted in only 1008 functional channels out of 1024 on this first generation prototype system. We experimentally observed backlit high speed fan blades in initial camera testing and then followed that with full movies and streak images of free flowing high speed plasma jets (at 30-50 km/s). Jet structure and jet collisions onto metal pillars in the path of the plasma jets were recorded in a single shot. This new fast imaging system is an attractive alternative to conventional fast framing cameras for applications and experiments where imaging events using existing techniques are inefficient or impossible. The development of HyperV's new diagnostic was split into two tracks: a next generation camera track, in which HyperV built, tested, and demonstrated a prototype 1024 channel camera at its own facility, and a second plasma community beta test track, where selected plasma physics programs received small systems of a few test pixels to evaluate the expected performance of a full scale camera on their experiments. These evaluations were performed as part of an unfunded collaboration with researchers at Los Alamos National Laboratory and the University of California at Davis. Results from the prototype 1024-pixel camera are discussed, as well as results from the collaborations with test pixel system deployment sites.« less
Code of Federal Regulations, 2011 CFR
2011-10-01
... issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections. (b) General requirements. As part of the inspection process, CMS or a CMS agent may require the... testing process (preanalytic, analytic, and postanalytic). (4) Permit CMS or a CMS agent access to all...
Code of Federal Regulations, 2012 CFR
2012-10-01
... issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections. (b) General requirements. As part of the inspection process, CMS or a CMS agent may require the... testing process (preanalytic, analytic, and postanalytic). (4) Permit CMS or a CMS agent access to all...
Code of Federal Regulations, 2013 CFR
2013-10-01
... issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections. (b) General requirements. As part of the inspection process, CMS or a CMS agent may require the... testing process (preanalytic, analytic, and postanalytic). (4) Permit CMS or a CMS agent access to all...
Code of Federal Regulations, 2014 CFR
2014-10-01
... issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections. (b) General requirements. As part of the inspection process, CMS or a CMS agent may require the... testing process (preanalytic, analytic, and postanalytic). (4) Permit CMS or a CMS agent access to all...
Code of Federal Regulations, 2010 CFR
2010-10-01
... issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections. (b) General requirements. As part of the inspection process, CMS or a CMS agent may require the... testing process (preanalytic, analytic, and postanalytic). (4) Permit CMS or a CMS agent access to all...
VIPRAM_L1CMS: a 2-Tier 3D Architecture for Pattern Recognition for Track Finding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoff, J. R.; Joshi, Joshi,S.; Liu, Liu,
In HEP tracking trigger applications, flagging an individual detector hit is not important. Rather, the path of a charged particle through many detector layers is what must be found. Moreover, given the increased luminosity projected for future LHC experiments, this type of track finding will be required within the Level 1 Trigger system. This means that future LHC experiments require not just a chip capable of high-speed track finding but also one with a high-speed readout architecture. VIPRAM_L1CMS is 2-Tier Vertically Integrated chip designed to fulfill these requirements. It is a complete pipelined Pattern Recognition Associative Memory (PRAM) architecture includingmore » pattern recognition, result sparsification, and readout for Level 1 trigger applications in CMS with 15-bit wide detector addresses and eight detector layers included in the track finding. Pattern recognition is based on classic Content Addressable Memories with a Current Race Scheme to reduce timing complexity and a 4-bit Selective Precharge to minimize power consumption. VIPRAM_L1CMS uses a pipelined set of priority-encoded binary readout structures to sparsify and readout active road flags at frequencies of at least 100MHz. VIPRAM_L1CMS is designed to work directly with the Pulsar2b Architecture.« less
Harmonisation of Global Land-Use Scenarios for the Period 1500-2100 for IPCC-AR5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurtt, George; Chini, Louise Parsons; Frolking, Steve
2009-06-01
In preparation for the fifth Intergovernmental Panel on Climate Change climate change assessment (IPCC-AR5), the international community is developing new advanced computer models (CMs) to address the combined effects of human activities (e.g. land-use and fossil fuel emissions) on the carbon-climate system. In addition, four Representative Concentration Pathway (RCP) scenarios of the future (2005-2100) are being developed by four Integrated Assessment Modeling teams (IAMs) to be used as input to the CMs for future climate projections. The diversity of requirements and approaches among CMs and IAMs for tracking land-use changes (past, present, and future), presents major challenges for treating land-usemore » comprehensively and consistently between these communities. As part of an international working group, we have been working to meet these challenges by developing a "harmonized" set of land-use change scenarios that smoothly connects gridded historical reconstructions of land-use with future projections, in a format required by CMs. This approach to harmonizing the treatment of land-use between two key modeling communities, CMs and IAMs, represents a major advance that will facilitate more consistent and fuller treatments of land-use/land-use change effects including both CO2 emissions and corresponding land-surface changes.« less
Non-coding RNA may be associated with cytoplasmic male sterility in Silene vulgaris
Stone, James D.; Koloušková, Pavla; Sloan, Daniel B.
2017-01-01
Abstract Cytoplasmic male sterility (CMS) is a widespread phenomenon in flowering plants caused by mitochondrial (mt) genes. CMS genes typically encode novel proteins that interfere with mt functions and can be silenced by nuclear fertility-restorer genes. Although the molecular basis of CMS is well established in a number of crop systems, our understanding of it in natural populations is far more limited. To identify CMS genes in a gynodioecious plant, Silene vulgaris, we constructed mt transcriptomes and compared transcript levels and RNA editing patterns in floral bud tissue from female and hermaphrodite full siblings. The transcriptomes from female and hermaphrodite individuals were very similar overall with respect to variation in levels of transcript abundance across the genome, the extent of RNA editing, and the order in which RNA editing and intron splicing events occurred. We found only a single genomic region that was highly overexpressed and differentially edited in females relative to hermaphrodites. This region is not located near any other transcribed elements and lacks an open-reading frame (ORF) of even moderate size. To our knowledge, this transcript would represent the first non-coding mt RNA associated with CMS in plants and is, therefore, an important target for future functional validation studies. PMID:28369520
“Exploring High Energy Interactions with CMS at the LHC”
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sulak, Lawrence R.
2016-08-01
This High Energy Physics research project achieved its goal of exploring high-energy interactions with 7, 8 and 13 TeV data accumulated by CMS at the Energy Frontier. For the original hadron calorimeter (HCAL) and for its upgrade during Long Shutdown 1 (LS1), the PI helped propose and implement the upgrading the phototubes, new electronics, and fast timing of the hadronic forward (HF) and hadronic outer (HO) calorimeters of CMS, projects which he had forcefully advocated since the inception of CMS. The PI and his colleagues Prof. J. Rohlf and chief electronics engineer E. Hazen, his post-docs A. Heister and S.more » Girgis, and his graduate students (P. Lawson and D. Arcaro) contributed software tools used in perfecting of μTCA and Advanced Mezzanine Card (AMC13) electronics, the PC board that provides clock, timing and DAQ service for HCAL (and now many other subdetectors and central systems in the upgraded CMS detector). This Task reaped the benefits of these hardware contributions 1) to hermiticity for missing energy searches, and 2) to forward tagging jets for Vector Boson Fusion processes by analyzing and publishing early data, including that for the Higgs discovery and for exotic and supersymmetric searches.« less
Passage Key Inlet, Florida; CMS Modeling and Borrow Site Impact Analysis
2016-06-01
Impact Analysis by Kelly R. Legault and Sirisha Rayaprolu PURPOSE: This Coastal and Hydraulics Engineering Technical Note (CHETN) describes the...use of a nested Coastal Modeling System (CMS) model for Passage Key Inlet, which is one of the connections between the Gulf of Mexico and Tampa Bay...driven sediment transport at Passage Key Inlet. This analysis resulted in issuing a new Florida Department of Environmental Protection (FDEP) permit to
RooStatsCms: A tool for analysis modelling, combination and statistical studies
NASA Astrophysics Data System (ADS)
Piparo, D.; Schott, G.; Quast, G.
2010-04-01
RooStatsCms is an object oriented statistical framework based on the RooFit technology. Its scope is to allow the modelling, statistical analysis and combination of multiple search channels for new phenomena in High Energy Physics. It provides a variety of methods described in literature implemented as classes, whose design is oriented to the execution of multiple CPU intensive jobs on batch systems or on the Grid.
Influence of Structural Flexibility on the Dynamic Precision of a Vehicle-Mounted Equipment System
2015-05-12
Paramsothy Jayakumar , Dave Mechergui, Ronald Renke U.S.Army RDECOM TARDEC INFLUENCE OF STRUCTURAL FLEXIBILITY ON THE DYNAMIC PRECISION OF A...COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE INFLUENCE OF STRUCTURAL FLEXIBILITY ON THE DYNAMIC PRECISION OF A VEHICLE-MOUNTED EQUIPMENT...Equipment Enclosure CMS Results 23 12. Influence of CMS Method on the Vehicle Dynamics 24 13. Influence of Flexibility on the Vehicle
Device-independent color scanning
NASA Astrophysics Data System (ADS)
Burger, Rudolph E.
1993-08-01
Color calibration technology is being incorporated into both Apple and Microsoft's operating systems. These color savvy operating systems will produce a market pull towards 'smart color' scanners and printers which, in turn, will lead towards a distributed architecture for color management systems (CMS). Today's desktop scanners produce red-green-blue color signals that do not accurately describe the color of the object being scanned. Future scanners will be self-calibrating and communicate their own 'device profile' to the operating system based CMS. This paper describes some of the key technologies required for this next generation of smart color scanners. Topics covered include a comparison of colorimetric and conventional scanning technologies, and the impact of metamerism, dye fluorescence and chromatic adaptation on device independent color scanning.
Simulation of Small-Pitch HgCdTe Photodetectors
NASA Astrophysics Data System (ADS)
Vallone, Marco; Goano, Michele; Bertazzi, Francesco; Ghione, Giovanni; Schirmacher, Wilhelm; Hanna, Stefan; Figgemeier, Heinrich
2017-09-01
Recent studies indicate as an important technological step the development of infrared HgCdTe-based focal plane arrays (FPAs) with sub-wavelength pixel pitch, with the advantage of smaller volume, lower weight, and potentially lower cost. In order to assess the limits of pixel pitch scaling, we present combined three-dimensional optical and electrical simulations of long-wavelength infrared HgCdTe FPAs, with 3 μm, 5 μm, and 10 μm pitch. Numerical simulations predict significant cavity effects, brought by the array periodicity. The optical and electrical contributions to spectral inter-pixel crosstalk are investigated as functions of pixel pitch, by illuminating the FPAs with Gaussian beams focused on the central pixel. Despite the FPAs being planar with 100% pixel duty cycle, our calculations suggest that the total crosstalk with nearest-neighbor pixels could be kept acceptably small also with pixels only 3 μ m wide and a diffraction-limited optical system.
Circularity measuring system: A shape gauge designed especially for use on large objects
NASA Technical Reports Server (NTRS)
Rohrkaste, G. R.
1990-01-01
The Circularity Measuring System (CMS) was developed to make an in-situ determination of shape similarity for selected fit large cylinders (RSRM segments). It does this to a repeatable accuracy of 0.10 mm (0.004 inch). This is less that the goal of 0.07 mm (0.003 inch), but was determined adequate because of the addition of an assembly aid that increased the entry chamfer of the clevis side of the joint. The usefulness of the CMS is demonstrated by the application to measurements other than its specified design purpose, such as submarine hull circularity, SRM mid-case circularity, as well as circularity of interfacing SRM tooling, specifically the rounding devices and horizontal disassembly devices. Commercialization of the tool is being pursued, since it is an enhancement of metrology technology for circularity determination. The most accurate in-situ technology it replaces is determined from a template. The CMS is an improvement in accuracy and operation.
Çalıkoğlu, Şule; Christmyer, Carol S; Kozlowski, Bruce U
2012-01-01
In 2008, the Centers for Medicaid and Medicare Services (CMS) launched the Five-Star Quality Rating System to help consumers compare nursing homes. The quality rating system consists of three domains: nursing home inspection results, staffing, and quality measures (QMs) and an overall rating calculated from the three domains. The Five-Star System has both advocates and detractors. One source of criticism about the rating system is its lack of input from consumer surveys. Although different dimensions of quality have been recognized as important by the experts and studied in the literature, how these dimensions are linked with each other is largely unknown. This article describes an analysis of the relationship between overall experience of care ratings from a family survey and ratings obtained on the CMS Five-Star Quality Rating for Maryland nursing homes. The results indicated a strong positive correlation between family experience of care score and two five-star domains, namely health inspections and nurse staffing, and no relationship with the quality domain. The lack of relationship between the quality domain and the family score may be due to inadequate risk adjustment or that each rating system measures different aspects of quality. © 2011 National Association for Healthcare Quality.
In-flight calibration of the Hitomi Soft X-ray Spectrometer. (2) Point spread function
NASA Astrophysics Data System (ADS)
Maeda, Yoshitomo; Sato, Toshiki; Hayashi, Takayuki; Iizuka, Ryo; Angelini, Lorella; Asai, Ryota; Furuzawa, Akihiro; Kelley, Richard; Koyama, Shu; Kurashima, Sho; Ishida, Manabu; Mori, Hideyuki; Nakaniwa, Nozomi; Okajima, Takashi; Serlemitsos, Peter J.; Tsujimoto, Masahiro; Yaqoob, Tahir
2018-03-01
We present results of inflight calibration of the point spread function of the Soft X-ray Telescope that focuses X-rays onto the pixel array of the Soft X-ray Spectrometer system. We make a full array image of a point-like source by extracting a pulsed component of the Crab nebula emission. Within the limited statistics afforded by an exposure time of only 6.9 ks and limited knowledge of the systematic uncertainties, we find that the raytracing model of 1 {^'.} 2 half-power-diameter is consistent with an image of the observed event distributions across pixels. The ratio between the Crab pulsar image and the raytracing shows scatter from pixel to pixel that is 40% or less in all except one pixel. The pixel-to-pixel ratio has a spread of 20%, on average, for the 15 edge pixels, with an averaged statistical error of 17% (1 σ). In the central 16 pixels, the corresponding ratio is 15% with an error of 6%.
Shimamoto, Yukiko; Kubo, Takashi; Tanabe, Kazumi; Emori, Hiroki; Katayama, Yosuke; Nishiguchi, Tsuyoshi; Taruya, Akira; Kameyama, Takeyoshi; Orii, Makoto; Yamano, Takashi; Kuroi, Akio; Yamaguchi, Tomoyuki; Takemoto, Kazushi; Matsuo, Yoshiki; Ino, Yasushi; Tanaka, Atsushi; Hozumi, Takeshi; Terada, Masaki; Akasaka, Takashi
2017-01-01
Previous animal studies have shown that a potassium channel opener, nicorandil, provokes vasodilation in renal microvasculature and increases renal blood flow. We conducted a clinical study that aimed to evaluate the effect of nicorandil on renal artery blood flow in comparison with nitroglycerin by using color Doppler ultrasound. The present study enrolled 40 patients with stable coronary artery disease who had no renal arterial stenosis and renal parenchymal disease. The patients received intravenous administration of nicorandil (n=20) or nitroglycerin (n=20). Before and after the administration, renal artery blood flow velocity was measured by color-guided pulsed-wave Doppler. The peak-systolic, end-diastolic, and mean renal artery blood flow velocities before the administration were not different between the nicorandil group and the nitroglycerin group. The peak-systolic (79±15cm/s to 99±21cm/s, p<0.001; and 78±19cm/s to 85±19cm/s, p=0.004), end-diastolic (22±5cm/s to 28±8cm/s, p<0.001; and 24±6cm/s to 26±6cm/s, p=0.005) and mean (41±6cm/s to 49±9cm/s, p<0.001; and 43±9cm/s to 45±9cm/s, p=0.009) renal artery flow velocities increased significantly in either group. The nominal changes in the peak-systolic (20±10cm/s vs. 7±8cm/s, p<0.001), end-diastolic (5±4cm/s vs. 2±3cm/s, p=0.001), and mean (8±5cm/s vs. 2±2cm/s, p<0.001) renal artery blood flow velocities were significantly greater in the nicorandil group compared with the nitroglycerin group. Intravenous nicorandil increased renal artery blood flow velocity in comparison with nitroglycerin. Nicorandil has a significant effect on renal hemodynamics. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Altered iPSC-derived neurons’ sodium channel properties in subjects with Monge's disease
Zhao, Huiwen W.; Gu, Xiang Q.; Chailangkarn, Thanathom; Perkins, Guy; Callacondo, David; Appenzeller, Otto; Poulsen, Orit; Zhou, Dan; Muotri, Alysson R.; Haddad, Gabriel G.
2015-01-01
Monge's disease, also known as chronic mountain sickness (CMS), is a disease that potentially threatens more than 140 million highlanders during extended time living at a high altitude (over 2500m). The prevalence of CMS in Andeans is about 15-20%, suggesting that the majority of highlanders (non-CMS) are rather healthy at the high altitude; however, CMS subjects experience severe hypoxemia, erythrocytosis and many neurologic manifestations including migraine, headache, mental fatigue, confusion, and memory loss. The underlying mechanisms of CMS neuropathology are not well understood and no ideal treatment is available to prevent or cure CMS, except for phlebotomy. In the current study, we reprogrammed fibroblast cells from both CMS and non-CMS subjects’ skin biopsies into the induced pluripotent stem cells (iPSCs), then differentiated into neurons and compared their neuronal properties. We discovered that CMS neurons were much less excitable (higher rheobase) than non-CMS neurons. This decreased excitability was not caused by differences in passive neuronal properties, but instead by a significantly lowered Na+ channel current density and by a shift of the voltage-conductance curve in the depolarization direction. Our findings provide, for the first time, evidence of a neuronal abnormality in CMS subjects as compared to non-CMS subjects, hoping that such studies can pave the way to a better understanding of the neuropathology in CMS. PMID:25559931
Navarrete, Enrique G; Liang, Ping; Lan, Feng; Sanchez-Freire, Verónica; Simmons, Chelsey; Gong, Tingyu; Sharma, Arun; Burridge, Paul W; Patlolla, Bhagat; Lee, Andrew S; Wu, Haodi; Beygui, Ramin E; Wu, Sean M; Robbins, Robert C; Bers, Donald M; Wu, Joseph C
2013-09-10
Drug-induced arrhythmia is one of the most common causes of drug development failure and withdrawal from market. This study tested whether human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) combined with a low-impedance microelectrode array (MEA) system could improve on industry-standard preclinical cardiotoxicity screening methods, identify the effects of well-characterized drugs, and elucidate underlying risk factors for drug-induced arrhythmia. hiPSC-CMs may be advantageous over immortalized cell lines because they possess similar functional characteristics as primary human cardiomyocytes and can be generated in unlimited quantities. Pharmacological responses of beating embryoid bodies exposed to a comprehensive panel of drugs at 65 to 95 days postinduction were determined. Responses of hiPSC-CMs to drugs were qualitatively and quantitatively consistent with the reported drug effects in literature. Torsadogenic hERG blockers, such as sotalol and quinidine, produced statistically and physiologically significant effects, consistent with patch-clamp studies, on human embryonic stem cell-derived cardiomyocytes hESC-CMs. False-negative and false-positive hERG blockers were identified accurately. Consistent with published studies using animal models, early afterdepolarizations and ectopic beats were observed in 33% and 40% of embryoid bodies treated with sotalol and quinidine, respectively, compared with negligible early afterdepolarizations and ectopic beats in untreated controls. We found that drug-induced arrhythmias can be recapitulated in hiPSC-CMs and documented with low impedance MEA. Our data indicate that the MEA/hiPSC-CM assay is a sensitive, robust, and efficient platform for testing drug effectiveness and for arrhythmia screening. This system may hold great potential for reducing drug development costs and may provide significant advantages over current industry standard assays that use immortalized cell lines or animal models.
Luo, Jun; Weaver, Matthew S; Dennis, James E; Whalen, Elizabeth; Laflamme, Michael A; Allen, Margaret D
2014-12-01
Generating myocyte grafts that bridge across infarcts could maximize their functional impact and best utilize small numbers of stem cells. To date, however, graft survival within acute infarcts has not been feasible. To enhance intrainfarct graft viability, human embryonic stem cell-derived cardiomyocytes (hESC-CMs) were pretreated before implantation with cobalt protoporphyrin (CoPP), a pharmacologic inducer of cytoprotective heme oxygenase-1. After preculturing with CoPP (vs phosphate-buffered saline), hESC-CMs were injected intramyocardially into acutely infarcted rat hearts, using directed injections to span the infarct. A further group received CoPP-pretreated hESC-CMs plus 4 weekly doses of systemic CoPP to prolong exposure to cytoprotectants. Two control groups with infarcts received vehicle-only intramyocardial injections or weekly systemic CoPP without cell therapy. Postinfarct ventricular function was gauged by echocardiography and graft size quantified at 8 weeks by histomorphometry. CoPP-preconditioned hESC-CMs formed stable grafts deep within infarcted myocardium, while grafts without CoPP exposure survived mainly at the infarct periphery. Fractional shortening was improved at 4 and 8 weeks in all hearts receiving cell therapies (P < .01 vs vehicle-only injections). CoPP treatment of both graft hESC-CMs and recipient animals resulted in the largest grafts, highest fractional shortening, preserved wall thickness, and reduced infarct dimensions. Cellular therapy delivered acutely after infarction significantly improved postinfarct ventricular function at 1 and 2 months. CoPP pretreatment of cells resulted in stable hESC-CM grafts within infarcted myocardium. This design enables construction of directionally oriented, infarct-spanning bands of new cardiomyocytes that might further improve functional restoration as engrafted myocytes proliferate and mature. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Yield performance and stability of CMS-based triticale hybrids.
Mühleisen, Jonathan; Piepho, Hans-Peter; Maurer, Hans Peter; Reif, Jochen Christoph
2015-02-01
CMS-based triticale hybrids showed only marginal midparent heterosis for grain yield and lower dynamic yield stability compared to inbred lines. Hybrids of triticale (×Triticosecale Wittmack) are expected to possess outstanding yield performance and increased dynamic yield stability. The objectives of the present study were to (1) examine the optimum choice of the biometrical model to compare yield stability of hybrids versus lines, (2) investigate whether hybrids exhibit a more pronounced grain yield performance and yield stability, and (3) study optimal strategies to predict yield stability of hybrids. Thirteen female and seven male parental lines and their 91 factorial hybrids as well as 30 commercial lines were evaluated for grain yield in up to 20 environments. Hybrids were produced using a cytoplasmic male sterility (CMS)-inducing cytoplasm that originated from Triticumtimopheevii Zhuk. We found that the choice of the biometrical model can cause contrasting results and concluded that a group-by-environment interaction term should be added to the model when estimating stability variance of hybrids and lines. midparent heterosis for grain yield was on average 3 % with a range from -15.0 to 11.5 %. No hybrid outperformed the best inbred line. Hybrids had, on average, lower dynamic yield stability compared to the inbred lines. Grain yield performance of hybrids could be predicted based on midparent values and general combining ability (GCA)-predicted values. In contrast, stability variance of hybrids could be predicted only based on GCA-predicted values. We speculated that negative effects of the used CMS cytoplasm might be the reason for the low performance and yield stability of the hybrids. For this purpose a detailed study on the reasons for the drawback of the currently existing CMS system in triticale is urgently required comprising also the search of potentially alternative hybridization systems.
NASA Astrophysics Data System (ADS)
Li, Yuanxun; Xie, Yunsong; Xie, Ru; Chen, Daming; Han, Likun; Su, Hua
2018-03-01
A glass-free ternary composite material system (CMS) manufactured employing the low temperature ( 890 ° C ) co-fired ceramic (LTCC) technique is reported. This ternary CMS consists of silver, NiCuZn ferrite, and Zn2SiO4 ceramic. The reported device fabricated from this ternary CMS is a power inductor with a nominal inductance of 1.0 μH. Three major highlights were achieved from the device and the material study. First, unlike most other LTCC methods, no glass is required to be added in either of the dielectric materials in order to co-fire the NiCuZn ferrite, Zn2SiO4 ceramic, and silver. Second, a successfully co-fired silver, NiCuZn, and Zn2SiO4 device can be achieved by optimizing the thermal shrinkage properties of both NiCuZn and Zn2SiO4, so that they have a very similar temperature shrinkage profile. We have also found that strong non-magnetic elemental diffusion occurs during the densification process, which further enhances the success rate of manufacturing co-fired devices. Last but not least, elemental mapping suggests that strong magnetic elemental diffusion between NiCuZn and Zn2SiO4 has been suppressed during the co-firing process. The investigation of electrical performance illustrates that while the ordinary binary CMS based power inductor can deal with 400 mA DC, the ternary CMS based power inductor is able to handle higher DC currents, 700 mA and 620 mA DC, according to both simulation and experiment demonstrations, respectively.
Sung, Iel-Yong; Son, Han-Na; Ullah, Imran; Bharti, Dinesh; Park, Ju-Mi; Cho, Yeong-Cheol; Byun, June-Ho; Kang, Young-Hoon; Sung, Su-Jin; Kim, Jong-Woo; Rho, Gyu-Jin; Park, Bong-Wook
2016-01-01
The purpose of the present study was to investigate the in vitro cardiomyogenic differentiation potential of human dental follicle-derived stem cells (DFCs) under the influence of suberoylanilide hydroxamic acid (SAHA), a member of the histone deacetylase inhibitor family, and analyze the in vivo homing capacity of induced cardiomyocytes (iCMs) when transplanted systemically. DFCs from extracted wisdom teeth showed mesenchymal stem cell (MSC) characteristics such as plate adherent growing, expression of MSC markers (CD44, CD90, and CD105), and mesenchymal lineage-specific differentiation potential. Adding SAHA to the culture medium induced the successful in vitro differentiation of DFCs into cardiomyocytes. These iCMs expressed cardiomyogenic markers, including alpha-smooth muscle actin (α-SMA), cardiac muscle troponin T (TNNT2), Desmin, and cardiac muscle alpha actin (ACTC1) , at both the mRNA and protein level. For the assessment of homing capacity, PKH26 labeled iCMs were intraperitoneally injected (1×10 6 cells in 100 µL of PBS) into the experimental mice, and the ratios of PKH26 positive cells to the total number of injected cells, in multiple organs were determined. The calculated homing ratios, 14 days after systemic cell transplantation, were 5.6 ± 1.0%, 3.6 ± 1.1%, and 11.6 ± 2.7% in heart, liver, and kidney respectively. There was no difference in the serum levels of interleukin-2 and interleukin-10 at 14 days after transplantation, between the experimental (iCM injected) and control (no injection or PBS injection) groups. These results demonstrate that DFCs can be an excellent source for cardiomyocyte differentiation and regeneration. Moreover, the iCMs can be delivered into heart muscle via systemic administration without eliciting inflammatory or immune response. This can serve as the pilot study for further investigations into the in vitro cardiomyogenic differentiation potential of DFCs under the influence of SAHA and the in vivo homing capacity of the iCMs into the heart muscle, when injected systemically.
A focal plane metrology system and PSF centroiding experiment
NASA Astrophysics Data System (ADS)
Li, Haitao; Li, Baoquan; Cao, Yang; Li, Ligang
2016-10-01
In this paper, we present an overview of a detector array equipment metrology testbed and a micro-pixel centroiding experiment currently under development at the National Space Science Center, Chinese Academy of Sciences. We discuss on-going development efforts aimed at calibrating the intra-/inter-pixel quantum efficiency and pixel positions for scientific grade CMOS detector, and review significant progress in achieving higher precision differential centroiding for pseudo star images in large area back-illuminated CMOS detector. Without calibration of pixel positions and intrapixel response, we have demonstrated that the standard deviation of differential centroiding is below 2.0e-3 pixels.
Jacobs, Jeffrey P; Shahian, David M; He, Xia; O'Brien, Sean M; Badhwar, Vinay; Cleveland, Joseph C; Furnary, Anthony P; Magee, Mitchell J; Kurlansky, Paul A; Rankin, J Scott; Welke, Karl F; Filardo, Giovanni; Dokholyan, Rachel S; Peterson, Eric D; Brennan, J Matthew; Han, Jane M; McDonald, Donna; Schmitz, DeLaine; Edwards, Fred H; Prager, Richard L; Grover, Frederick L
2016-01-01
The Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database (ACSD) has been successfully linked to the Centers for Medicare and Medicaid (CMS) Medicare database, thereby facilitating comparative effectiveness research and providing information about long-term follow-up and cost. The present study uses this link to determine contemporary completeness, penetration, and representativeness of the STS ACSD. Using variables common to both STS and CMS databases, STS operations were linked to CMS data for all CMS coronary artery bypass graft (CABG) surgery hospitalizations discharged between 2000 and 2012, inclusive. For each CMS CABG hospitalization, it was determined whether a matching STS record existed. Center-level penetration (number of CMS sites with at least one matched STS participant divided by the total number of CMS CABG sites) increased from 45% in 2000 to 90% in 2012. In 2012, 973 of 1,081 CMS CABG sites (90%) were linked to an STS site. Patient-level penetration (number of CMS CABG hospitalizations done at STS sites divided by the total number of CMS CABG hospitalizations) increased from 51% in 2000 to 94% in 2012. In 2012, 71,634 of 76,072 CMS CABG hospitalizations (94%) occurred at an STS site. Completeness of case inclusion at STS sites (number of CMS CABG cases at STS sites linked to STS records divided by the total number of CMS CABG cases at STS sites) increased from 88% in 2000 to 98% in 2012. In 2012, 69,213 of 70,932 CMS CABG hospitalizations at STS sites (98%) were linked to an STS record. Linkage of STS and CMS databases demonstrates high and increasing penetration and completeness of the STS database. Linking STS and CMS data facilitates studying long-term outcomes and costs of cardiothoracic surgery. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Image reconstruction of dynamic infrared single-pixel imaging system
NASA Astrophysics Data System (ADS)
Tong, Qi; Jiang, Yilin; Wang, Haiyan; Guo, Limin
2018-03-01
Single-pixel imaging technique has recently received much attention. Most of the current single-pixel imaging is aimed at relatively static targets or the imaging system is fixed, which is limited by the number of measurements received through the single detector. In this paper, we proposed a novel dynamic compressive imaging method to solve the imaging problem, where exists imaging system motion behavior, for the infrared (IR) rosette scanning system. The relationship between adjacent target images and scene is analyzed under different system movement scenarios. These relationships are used to build dynamic compressive imaging models. Simulation results demonstrate that the proposed method can improve the reconstruction quality of IR image and enhance the contrast between the target and the background in the presence of system movement.
Wu, Jianyong; Zhang, Meng; Zhang, Bingbing; Zhang, Xuexian; Guo, Liping; Qi, Tingxiang; Wang, Hailin; Zhang, Jinfa; Xing, Chaozhu
2017-06-08
Cytoplasmic male sterility (CMS) conferred by the cytoplasm from Gossypium harknessii (D2) is an important system for hybrid seed production in Upland cotton (G. hirsutum). The male sterility of CMS-D2 (i.e., A line) can be restored to fertility by a restorer (i.e., R line) carrying the restorer gene Rf1 transferred from the D2 nuclear genome. However, the molecular mechanisms of CMS-D2 and its restoration are poorly understood. In this study, a genome-wide comparative transcriptome analysis was performed to identify differentially expressed genes (DEGs) in flower buds among the isogenic fertile R line and sterile A line derived from a backcross population (BC 8 F 1 ) and the recurrent parent, i.e., the maintainer (B line). A total of 1464 DEGs were identified among the three isogenic lines, and the Rf1-carrying Chr_D05 and its homeologous Chr_A05 had more DEGs than other chromosomes. The results of GO and KEGG enrichment analysis showed differences in circadian rhythm between the fertile and sterile lines. Eleven DEGs were selected for validation using qRT-PCR, confirming the accuracy of the RNA-seq results. Through genome-wide comparative transcriptome analysis, the differential expression profiles of CMS-D2 and its maintainer and restorer lines in Upland cotton were identified. Our results provide an important foundation for further studies into the molecular mechanisms of the interactions between the restorer gene Rf1 and the CMS-D2 cytoplasm.
Rhode Island congestion management plan : executive summary
DOT National Transportation Integrated Search
1997-09-01
This document provides an overview of the Rhode Island Congestion Management System (CMS) program consisting of the following: Congestion Management System Plan; Incident Management Plan; and Intelligent Transportation System (ITS) Early Deployment P...
78 FR 38986 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-28
... that information was collected under Part B. The QIMS Account Registration and the ESRD Application..., CMS-1728-94, CMS-10174, CMS-10305 and CMS-10488] Agency Information Collection Activities: Proposed... comment on CMS' intention to collect information from the public. Under the Paperwork Reduction Act of...
42 CFR 482.74 - Condition of participation: Notification to CMS.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Condition of participation: Notification to CMS... participation: Notification to CMS. (a) A transplant center must notify CMS immediately of any significant... conditions of participation. Instances in which CMS should receive information for follow up, as appropriate...
Braun, Lesley A; Tiralongo, Evelin; Wilkinson, Jenny M; Spitzer, Ondine; Bailey, Michael; Poole, Susan; Dooley, Michael
2010-07-20
Complementary medicines (CMs) are popular amongst Australians and community pharmacy is a major supplier of these products. This study explores pharmacy customer use, attitudes and perceptions of complementary medicines, and their expectations of pharmacists as they relate to these products. Pharmacy customers randomly selected from sixty large and small, metropolitan and rural pharmacies in three Australian states completed an anonymous, self administered questionnaire that had been pre-tested and validated. 1,121 customers participated (response rate 62%). 72% had used CMs within the previous 12 months, 61% used prescription medicines daily and 43% had used both concomitantly. Multivitamins, fish oils, vitamin C, glucosamine and probiotics were the five most popular CMs. 72% of people using CMs rated their products as 'very effective' or 'effective enough'. CMs were as frequently used by customers aged 60 years or older as younger customers (69% vs. 72%) although the pattern of use shifted with older age. Most customers (92%) thought pharmacists should provide safety information about CMs, 90% thought they should routinely check for interactions, 87% thought they should recommend effective CMs, 78% thought CMs should be recorded in customer's medication profile and 58% thought pharmacies stocking CMs should also employ a complementary medicine practitioner. Of those using CMs, 93% thought it important for pharmacists to be knowledgeable about CMs and 48% felt their pharmacist provides useful information about CMs. CMs are widely used by pharmacy customers of all ages who want pharmacists to be more involved in providing advice about these products.
First Operational Experience With a High-Energy Physics Run Control System Based on Web Technologies
NASA Astrophysics Data System (ADS)
Bauer, Gerry; Beccati, Barbara; Behrens, Ulf; Biery, Kurt; Branson, James; Bukowiec, Sebastian; Cano, Eric; Cheung, Harry; Ciganek, Marek; Cittolin, Sergio; Coarasa Perez, Jose Antonio; Deldicque, Christian; Erhan, Samim; Gigi, Dominique; Glege, Frank; Gomez-Reino, Robert; Gulmini, Michele; Hatton, Derek; Hwong, Yi Ling; Loizides, Constantin; Ma, Frank; Masetti, Lorenzo; Meijers, Frans; Meschi, Emilio; Meyer, Andreas; Mommsen, Remigius K.; Moser, Roland; O'Dell, Vivian; Oh, Alexander; Orsini, Luciano; Paus, Christoph; Petrucci, Andrea; Pieri, Marco; Racz, Attila; Raginel, Olivier; Sakulin, Hannes; Sani, Matteo; Schieferdecker, Philipp; Schwick, Christoph; Shpakov, Dennis; Simon, Michal; Sumorok, Konstanty; Yoon, Andre Sungho
2012-08-01
Run control systems of modern high-energy particle physics experiments have requirements similar to those of today's Internet applications. The Compact Muon Solenoid (CMS) collaboration at CERN's Large Hadron Collider (LHC) therefore decided to build the run control system for its detector based on web technologies. The system is composed of Java Web Applications distributed over a set of Apache Tomcat servlet containers that connect to a database back-end. Users interact with the system through a web browser. The present paper reports on the successful scaling of the system from a small test setup to the production data acquisition system that comprises around 10.000 applications running on a cluster of about 1600 hosts. We report on operational aspects during the first phase of operation with colliding beams including performance, stability, integration with the CMS Detector Control System and tools to guide the operator.
Beck, Donghyun; Lee, Minho; Park, Woojin
2017-12-01
This study conducted a driving simulator experiment to comparatively evaluate three in-vehicle side view displays layouts for camera monitor systems (CMS) and the traditional side view mirror arrangement. The three layouts placed two electronic side view displays near the traditional mirrors positions, on the dashboard at each side of the steering wheel and on the centre fascia with the two displays joined side-by-side, respectively. Twenty-two participants performed a time- and safety-critical driving task that required rapidly gaining situation awareness through the side view displays/mirrors and making a lane change to avoid collision. The dependent variables were eye-off-the-road time, response time, and, ratings of perceived workload, preference and perceived safety. Overall, the layout placing the side view displays on the dashboard at each side of the steering wheel was found to be the best. The results indicated that reducing eye gaze travel distance and maintaining compatibility were both important for the design of CMS displays layout. Practitioner Summary: A driving simulator study was conducted to comparatively evaluate three in-vehicle side view displays layouts for camera monitor systems (CMS) and the traditional side view mirror arrangement in critical lane changing situation. Reducing eye movement and maintaining compatibility were found to be both important for the ergonomics design of CMS displays layout.
Achieving High Performance With TCP Over 40 GbE on NUMA Architectures for CMS Data Acquisition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bawej, Tomasz; et al.
2014-01-01
TCP and the socket abstraction have barely changed over the last two decades, but at the network layer there has been a giant leap from a few megabits to 100 gigabits in bandwidth. At the same time, CPU architectures have evolved into the multicore era and applications are expected to make full use of all available resources. Applications in the data acquisition domain based on the standard socket library running in a Non-Uniform Memory Access (NUMA) architecture are unable to reach full efficiency and scalability without the software being adequately aware about the IRQ (Interrupt Request), CPU and memory affinities.more » During the first long shutdown of LHC, the CMS DAQ system is going to be upgraded for operation from 2015 onwards and a new software component has been designed and developed in the CMS online framework for transferring data with sockets. This software attempts to wrap the low-level socket library to ease higher-level programming with an API based on an asynchronous event driven model similar to the DAT uDAPL API. It is an event-based application with NUMA optimizations, that allows for a high throughput of data across a large distributed system. This paper describes the architecture, the technologies involved and the performance measurements of the software in the context of the CMS distributed event building.« less
Tian, Yongqiang; Wang, Qing; Zhang, Weihua; Gao, Lihong
2016-02-15
Continuous cropping is a common agricultural practice in the word. In China, farmers often apply excessive fertilizers to fields in an attempt to maintain yields in continuous cropping systems. However, this practice often results in high nutrient concentrations in soils, nutrient pollution in leaching water and more crop disease. Here, we investigated 8 different soils from continuously cropped cucumbers in Northern China that grouped into those with extremely high nutrient levels (EHNL) and those with lower nutrient levels (LNL). All soils were treated with Caragana microphylla-straw (CMS) compost addition, and then were used to measure soil physiochemical and microbial properties, leaching water quality, plant root growth and cucumber fruit yield. In general, the EHNL-soil showed higher nitrate, phosphorus and potassium concentrations in the leaching water compared to the LNL-soil. However, the CMS compost application increased soil nutrient and water holding capacities, total microbial biomass (bacteria and fungi), root length, plant biomass and fruit yields, but decreased nutrient concentrations in the leaching water from the EHNL-soil. In addition, the CMS compost decreased the number of Fusarium oxysporum f. sp. cucumerinum in soils with very high concentration of mineral nitrogen. Our results infer that CMS compost application was an effective method for reducing environmental risk of excessively fertilized soils. Copyright © 2015 Elsevier B.V. All rights reserved.
Data Bookkeeping Service 3 - Providing Event Metadata in CMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giffels, Manuel; Guo, Y.; Riley, Daniel
The Data Bookkeeping Service 3 provides a catalog of event metadata for Monte Carlo and recorded data of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. It comprises all necessary information for tracking datasets, their processing history and associations between runs, files and datasets, on a large scale of about 200, 000 datasets and more than 40 million files, which adds up in around 700 GB of metadata. The DBS is an essential part of the CMS Data Management and Workload Management (DMWM) systems [1], all kind of data-processing like Monte Carlo production,more » processing of recorded event data as well as physics analysis done by the users are heavily relying on the information stored in DBS.« less
Readout of a 176 pixel FDM system for SAFARI TES arrays
NASA Astrophysics Data System (ADS)
Hijmering, R. A.; den Hartog, R.; Ridder, M.; van der Linden, A. J.; van der Kuur, J.; Gao, J. R.; Jackson, B.
2016-07-01
In this paper we present the results of our 176-pixel prototype of the FDM readout system for SAFARI, a TES-based focal-plane instrument for the far-IR SPICA mission. We have implemented the knowledge obtained from the detailed study on electrical crosstalk reported previously. The effect of carrier leakage is reduced by a factor two, mutual impedance is reduced to below 1 nH and mutual inductance is removed. The pixels are connected in stages, one quarter of the array half of the array and the full array, to resolve intermediate technical issues. A semi-automated procedure was incorporated to find all optimal settings for all pixels. And as a final step the complete array has been connected and 132 pixels have been read out simultaneously within the frequency range of 1-3.8MHz with an average frequency separation of 16kHz. The noise was found to be detector limited and was not affected by reading out all pixels in a FDM mode. With this result the concept of using FDM for multiplexed bolometer read out for the SAFARI instrument has been demonstrated.
Adverse systemic arterial function in patients with selenium deficiency.
Chan, Y-H; Siu, C-W; Yiu, K-H; Chan, H-T; Li, S-W; Tam, S; Cheung, B M; Lau, C-P; Lam, T H; Tse, H-F
2012-01-01
Experimental studies have shown that selenium is involved in the synthesis of selenoproteins which might contribute to cardiovascular protection. However, the relationship between selenium deficiency and vascular function in clinical context remains unknown. To investigate for any relationship between selenium deficiency and systemic arterial function in patients with high risk of vascular events. Cross-sectional study. 306 consecutive patients with high risk for cardiovascular events (coronary artery disease 35%, acute/ recurrent ischemic stroke 40%, diabetes mellitus 54%) followed up at internal medicine outpatient clinics. Non-invasive brachial-ankle pulse wave velocity (PWV) was determined using vascular profiling system (VP-2000). Long-term intake of selenium was determined by a validated food frequency questionnaire. Mean daily selenium intake was 59.5 ± 52.1 mcg/day, and mean PWV was 1782.4 ± 418.4 cm/s. Patients with selenium intake <10th percentile had significantly higher PWV as compared to patients with intake ≥ 10th percentile (1968.2 ± 648.9 cm/s versus 1762.2 ± 381.6 cm/s, P=0.010). After adjusting for potential confounders including age, gender, history of hypertension, hyperlipidemia, diabetes and cardiovascular disease, smoking status, use of cardiovascular medications, waist-hip ratio, education/ financial status, physical activity, calorie intake and intake of antioxidant vitamins, deficient selenium intake <10th percentile remained independently predictive of increased PWV by +363.4 cm/s [95% CI: 68.1 to 658.6, P=0.016, relative increase 21%]. Selenium deficiency is associated with adverse arterial function in patients with high risk for vascular events.
Multi-core processing and scheduling performance in CMS
NASA Astrophysics Data System (ADS)
Hernández, J. M.; Evans, D.; Foulkes, S.
2012-12-01
Commodity hardware is going many-core. We might soon not be able to satisfy the job memory needs per core in the current single-core processing model in High Energy Physics. In addition, an ever increasing number of independent and incoherent jobs running on the same physical hardware not sharing resources might significantly affect processing performance. It will be essential to effectively utilize the multi-core architecture. CMS has incorporated support for multi-core processing in the event processing framework and the workload management system. Multi-core processing jobs share common data in memory, such us the code libraries, detector geometry and conditions data, resulting in a much lower memory usage than standard single-core independent jobs. Exploiting this new processing model requires a new model in computing resource allocation, departing from the standard single-core allocation for a job. The experiment job management system needs to have control over a larger quantum of resource since multi-core aware jobs require the scheduling of multiples cores simultaneously. CMS is exploring the approach of using whole nodes as unit in the workload management system where all cores of a node are allocated to a multi-core job. Whole-node scheduling allows for optimization of the data/workflow management (e.g. I/O caching, local merging) but efficient utilization of all scheduled cores is challenging. Dedicated whole-node queues have been setup at all Tier-1 centers for exploring multi-core processing workflows in CMS. We present the evaluation of the performance scheduling and executing multi-core workflows in whole-node queues compared to the standard single-core processing workflows.
Miyamoto, Kazutaka; Akiyama, Mizuha; Tamura, Fumiya; Isomi, Mari; Yamakawa, Hiroyuki; Sadahiro, Taketaro; Muraoka, Naoto; Kojima, Hidenori; Haginiwa, Sho; Kurotsu, Shota; Tani, Hidenori; Wang, Li; Qian, Li; Inoue, Makoto; Ide, Yoshinori; Kurokawa, Junko; Yamamoto, Tsunehisa; Seki, Tomohisa; Aeba, Ryo; Yamagishi, Hiroyuki; Fukuda, Keiichi; Ieda, Masaki
2018-01-04
Direct cardiac reprogramming holds great promise for regenerative medicine. We previously generated directly reprogrammed induced cardiomyocyte-like cells (iCMs) by overexpression of Gata4, Mef2c, and Tbx5 (GMT) using retrovirus vectors. However, integrating vectors pose risks associated with insertional mutagenesis and disruption of gene expression and are inefficient. Here, we show that Sendai virus (SeV) vectors expressing cardiac reprogramming factors efficiently and rapidly reprogram both mouse and human fibroblasts into integration-free iCMs via robust transgene expression. SeV-GMT generated 100-fold more beating iCMs than retroviral-GMT and shortened the duration to induce beating cells from 30 to 10 days in mouse fibroblasts. In vivo lineage tracing revealed that the gene transfer of SeV-GMT was more efficient than retroviral-GMT in reprogramming resident cardiac fibroblasts into iCMs in mouse infarct hearts. Moreover, SeV-GMT improved cardiac function and reduced fibrosis after myocardial infarction. Thus, efficient, non-integrating SeV vectors may serve as a powerful system for cardiac regeneration. Copyright © 2017 Elsevier Inc. All rights reserved.
42 CFR 423.2063 - Applicability of laws, regulations and CMS Rulings.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false Applicability of laws, regulations and CMS Rulings..., ALJ Hearings, MAC review, and Judicial Review § 423.2063 Applicability of laws, regulations and CMS... on ALJs and the MAC. (b) CMS Rulings are published under the authority of the CMS Administrator...
42 CFR 426.517 - CMS' statement regarding new evidence.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false CMS' statement regarding new evidence. 426.517... DETERMINATIONS Review of an NCD § 426.517 CMS' statement regarding new evidence. (a) CMS may review any new... experts; and (5) Presented during any hearing. (b) CMS may submit a statement regarding whether the new...
42 CFR 405.1063 - Applicability of laws, regulations and CMS Rulings.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Applicability of laws, regulations and CMS Rulings... Medicare Coverage Policies § 405.1063 Applicability of laws, regulations and CMS Rulings. (a) All laws and... the MAC. (b) CMS Rulings are published under the authority of the Administrator, CMS. Consistent with...
Lorenzoni, Paulo José; Scola, Rosana Herminia; Kay, Claudia Suemi Kamoi; Werneck, Lineu Cesar; Horvath, Rita; Lochmüller, Hanns
2018-06-01
Congenital myasthenic syndromes (CMS) are heterogeneous genetic diseases in which neuromuscular transmission is compromised. CMS resembling the Lambert-Eaton myasthenic syndrome (CMS-LEMS) are emerging as a rare group of distinct presynaptic CMS that share the same electrophysiological features. They have low compound muscular action potential amplitude that increment after brief exercise (facilitation) or high-frequency repetitive nerve stimulation. Although clinical signs similar to LEMS can be present, the main hallmark is the electrophysiological findings, which are identical to autoimmune LEMS. CMS-LEMS occurs due to deficits in acetylcholine vesicle release caused by dysfunction of different components in its pathway. To date, the genes that have been associated with CMS-LEMS are AGRN, SYT2, MUNC13-1, VAMP1, and LAMA5. Clinicians should keep in mind these newest subtypes of CMS-LEMS to achieve the correct diagnosis and therapy. We believe that CMS-LEMS must be included as an important diagnostic clue to genetic investigation in the diagnostic algorithms to CMS. We briefly review the main features of CMS-LEMS.
File-Based Data Flow in the CMS Filter Farm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andre, J.M.; et al.
2015-12-23
During the LHC Long Shutdown 1, the CMS Data Acquisition system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and prepare the ground for future upgrades of the detector front-ends. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. This approach provides additional decoupling between the HLT algorithms and the input and output data flow. All the metadata needed for bookkeeping of the data flow and the HLT process lifetimes aremore » also generated in the form of small “documents” using the JSON encoding, by either services in the flow of the HLT execution (for rates etc.) or watchdog processes. These “files” can remain memory-resident or be written to disk if they are to be used in another part of the system (e.g. for aggregation of output data). We discuss how this redesign improves the robustness and flexibility of the CMS DAQ and the performance of the system currently being commissioned for the LHC Run 2.« less
The CMS Data Management System
NASA Astrophysics Data System (ADS)
Giffels, M.; Guo, Y.; Kuznetsov, V.; Magini, N.; Wildish, T.
2014-06-01
The data management elements in CMS are scalable, modular, and designed to work together. The main components are PhEDEx, the data transfer and location system; the Data Booking Service (DBS), a metadata catalog; and the Data Aggregation Service (DAS), designed to aggregate views and provide them to users and services. Tens of thousands of samples have been cataloged and petabytes of data have been moved since the run began. The modular system has allowed the optimal use of appropriate underlying technologies. In this contribution we will discuss the use of both Oracle and NoSQL databases to implement the data management elements as well as the individual architectures chosen. We will discuss how the data management system functioned during the first run, and what improvements are planned in preparation for 2015.
El-Sheikh, Manal A
2016-11-05
The photosensitized grafting of vinyl monomers onto a range of polymeric substrates has been the subject of particular interest in the recent past. Carboxymethyl starch (CMS)-poly acrylamide (PAAm) graft copolymer (CMS-g-PAAm) with high graft yield was successfully prepared by grafting of acrylamide onto CMS using UV irradiation in the presence of the water soluble 4-(trimethyl ammoniummethyl) benzophenone chloride photoinitiator. CMS-g-PAAm with nitrogen content of 8.3% and grafting efficiency up to 98.9% was obtained using 100% AAm, a material: liquor ratio of 1:14 and 1% photinitiator at 30°C for 1h of UV irradiation. The synthesis of CMS-g-PAAm was confirmed by FTIR and Nitrogen content (%). Surface morphology of CMS and surface morphological changes of CMS after grafting with AAm were studied using SEM. Thermal properties of both CMS and CMS-g-PAAm were studied using TGA and DSC. To impart easy care finishing to cotton fabrics, aqueous formulations of: CMS-g-PAAm, dimethylol dihydroxy ethylene urea (DMDHEU), CMS-g-PAAm-DMDHEU mixture or methylolated CMS-g-PAAm were used. Cotton fabrics were padded in these formulations, squeezed to a wet pick up 100%, dried at 100°C for 5min, cured at 150°C for 5min, washed at 50°C for 10min and air-dried. CRA (crease recovery angle) of untreated fabrics and fabrics finished with a mixture of 2% CMS-g-PAAm and 10% DMDHEU or methylolated CMS-g-PAAm (10% formaldehyde) were: 136°, 190°, 288° respectively. Increasing the number of washing cycles up to five cycles results in an insignificant decrease in the CRA and a significant decrease in RF (releasable formaldehyde) of finished fabric samples. The morphologies of the finished and unfinished cotton fabrics were performed by SEM. Copyright © 2016 Elsevier Ltd. All rights reserved.
Carotid Stenosis And Ulcer Detectability As A Function Of Pixel Size
NASA Astrophysics Data System (ADS)
Mintz, Leslie J.; Enzmann, Dieter R.; Keyes, Gary S.; Mainiero, Louis M.; Brody, William R.
1981-11-01
Digital radiography, in conjunction with digital subtraction methods can provide high quality images of the vascular system,1-4 Spatial resolution is one important limiting factor of this imaging technique. Since spatial resolution of a digital image is a function of pixel size, it is important to determine the pixel size threshold necessary to provide information comparable to that of conventional angiograms. This study was designed to establish the pixel size necessary to identify accurately stenotic and ulcerative lesions of the carotid artery.
2010-01-01
Background Complementary medicines (CMs) are popular amongst Australians and community pharmacy is a major supplier of these products. This study explores pharmacy customer use, attitudes and perceptions of complementary medicines, and their expectations of pharmacists as they relate to these products. Methods Pharmacy customers randomly selected from sixty large and small, metropolitan and rural pharmacies in three Australian states completed an anonymous, self administered questionnaire that had been pre-tested and validated. Results 1,121 customers participated (response rate 62%). 72% had used CMs within the previous 12 months, 61% used prescription medicines daily and 43% had used both concomitantly. Multivitamins, fish oils, vitamin C, glucosamine and probiotics were the five most popular CMs. 72% of people using CMs rated their products as 'very effective' or 'effective enough'. CMs were as frequently used by customers aged 60 years or older as younger customers (69% vs. 72%) although the pattern of use shifted with older age. Most customers (92%) thought pharmacists should provide safety information about CMs, 90% thought they should routinely check for interactions, 87% thought they should recommend effective CMs, 78% thought CMs should be recorded in customer's medication profile and 58% thought pharmacies stocking CMs should also employ a complementary medicine practitioner. Of those using CMs, 93% thought it important for pharmacists to be knowledgeable about CMs and 48% felt their pharmacist provides useful information about CMs. Conclusions CMs are widely used by pharmacy customers of all ages who want pharmacists to be more involved in providing advice about these products. PMID:20646290
Pixel-by-pixel absolute phase retrieval using three phase-shifted fringe patterns without markers
NASA Astrophysics Data System (ADS)
Jiang, Chufan; Li, Beiwen; Zhang, Song
2017-04-01
This paper presents a method that can recover absolute phase pixel by pixel without embedding markers on three phase-shifted fringe patterns, acquiring additional images, or introducing additional hardware component(s). The proposed three-dimensional (3D) absolute shape measurement technique includes the following major steps: (1) segment the measured object into different regions using rough priori knowledge of surface geometry; (2) artificially create phase maps at different z planes using geometric constraints of structured light system; (3) unwrap the phase pixel by pixel for each region by properly referring to the artificially created phase map; and (4) merge unwrapped phases from all regions into a complete absolute phase map for 3D reconstruction. We demonstrate that conventional three-step phase-shifted fringe patterns can be used to create absolute phase map pixel by pixel even for large depth range objects. We have successfully implemented our proposed computational framework to achieve absolute 3D shape measurement at 40 Hz.
A pixel read-out architecture implementing a two-stage token ring, zero suppression and compression
NASA Astrophysics Data System (ADS)
Heuvelmans, S.; Boerrigter, M.
2011-01-01
Increasing luminosity in high energy physics experiments leads to new challenges in the design of data acquisition systems for pixel detectors. With the upgrade of the LHCb experiment, the data processing will be changed; hit data from every collision will be transported off the pixel chip, without any trigger selection. A read-out architecture is proposed which is able to obtain low hit data loss on limited silicon area by using the logic beneath the pixels as a data buffer. Zero suppression and redundancy reduction ensure that the data rate off chip is minimized. A C++ model has been created for simulation of functionality and data loss, and for system development. A VHDL implementation has been derived from this model.
NASA Astrophysics Data System (ADS)
Chen, Chao; Gao, Nan; Wang, Xiangjun; Zhang, Zonghua
2018-05-01
Three-dimensional (3D) shape measurement based on fringe pattern projection techniques has been commonly used in various fields. One of the remaining challenges in fringe pattern projection is that camera sensor saturation may occur if there is a large range of reflectivity variation across the surface that causes measurement errors. To overcome this problem, a novel fringe pattern projection method is proposed to avoid image saturation and maintain high-intensity modulation for measuring shiny surfaces by adaptively adjusting the pixel-to-pixel projection intensity according to the surface reflectivity. First, three sets of orthogonal color fringe patterns and a sequence of uniform gray-level patterns with different gray levels are projected onto a measured surface by a projector. The patterns are deformed with respect to the object surface and captured by a camera from a different viewpoint. Subsequently, the optimal projection intensity at each pixel is determined by fusing different gray levels and transforming the camera pixel coordinate system into the projector pixel coordinate system. Finally, the adapted fringe patterns are created and used for 3D shape measurement. Experimental results on a flat checkerboard and shiny objects demonstrate that the proposed method can measure shiny surfaces with high accuracy.
Estimating job runtime for CMS analysis jobs
NASA Astrophysics Data System (ADS)
Sfiligoi, I.
2014-06-01
The basic premise of pilot systems is to create an overlay scheduling system on top of leased resources. And by definition, leases have a limited lifetime, so any job that is scheduled on such resources must finish before the lease is over, or it will be killed and all the computation is wasted. In order to effectively schedule jobs to resources, the pilot system thus requires the expected runtime of the users' jobs. Past studies have shown that relying on user provided estimates is not a valid strategy, so the system should try to make an estimate by itself. This paper provides a study of the historical data obtained from the Compact Muon Solenoid (CMS) experiment's Analysis Operations submission system. Clear patterns are observed, suggesting that making prediction of an expected job lifetime range is achievable with high confidence level in this environment.
Digital micromirror device camera with per-pixel coded exposure for high dynamic range imaging.
Feng, Wei; Zhang, Fumin; Wang, Weijing; Xing, Wei; Qu, Xinghua
2017-05-01
In this paper, we overcome the limited dynamic range of the conventional digital camera, and propose a method of realizing high dynamic range imaging (HDRI) from a novel programmable imaging system called a digital micromirror device (DMD) camera. The unique feature of the proposed new method is that the spatial and temporal information of incident light in our DMD camera can be flexibly modulated, and it enables the camera pixels always to have reasonable exposure intensity by DMD pixel-level modulation. More importantly, it allows different light intensity control algorithms used in our programmable imaging system to achieve HDRI. We implement the optical system prototype, analyze the theory of per-pixel coded exposure for HDRI, and put forward an adaptive light intensity control algorithm to effectively modulate the different light intensity to recover high dynamic range images. Via experiments, we demonstrate the effectiveness of our method and implement the HDRI on different objects.
Krejza, J; Rudzinski, W; Pawlak, M A; Tomaszewski, M; Ichord, R; Kwiatkowski, J; Gor, D; Melhem, E R
2007-09-01
Nonimaging transcranial Doppler sonography (TCD) and imaging TCD (TCDI) are used for determination of the risk of stroke in children with sickle cell disease (SCD). The purpose was to compare angle-corrected, uncorrected TCDI, and TCD blood flow velocities in children with SCD. A total of 37 children (mean age, 7.8 +/- 3.0 years) without intracranial arterial narrowing determined with MR angiography, were studied with use of TCD and TCDI at the same session. Depth of insonation and TCDI mean velocities with and without correction for the angle of insonation in the terminal internal carotid artery (ICA) and middle (MCA), anterior (ACA), and posterior (PCA) cerebral arteries were compared with TCD velocities with use of a paired t test. Two arteries were not found on TCDI compared with 15 not found on TCD. Average angle of insonation in the MCA, ACA, ICA, and PCA was 31 degrees , 44 degrees , 25 degrees , and 29 degrees , respectively. TCDI and TCD mean depth of insonation for all arteries did not differ significantly; however, individual differences varied substantially. TCDI velocities were significantly lower than TCD velocities, respectively, for the right and left sides (mean +/- SD): MCA, 106 +/- 22 cm/s and 111 +/- 33 cm/s versus 130 +/- 19 cm/s and 134 +/- 26 cm/s; ICA, 90 +/- 14 cm/s and 98 +/- 27 cm/s versus 117 +/- 18 cm/s and 119 +/- 23 cm/s; ACA, 74 +/- 24 cm/s and 88 +/- 25 cm/s versus 105 +/- 23 cm/s and 105 +/- 31 cm/s; and PCA, 84 +/- 27 cm/s and 82 +/- 21 cm/s versus 95 +/- 23 cm/s and 94 +/- 20 cm/s. TCD and angle-corrected TCDI velocities were not statistically different except for higher angle-corrected TCDI values in the left ACA and right PCA. TCD velocities are significantly higher than TCDI velocities but are not different from the angle-corrected TCDI velocities. TCDI identifies the major intracranial arteries more effectively than TCD.
Experimental High Energy Physics Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hohlmann, Marcus
This final report summarizes activities of the Florida Tech High Energy Physics group supported by DOE under grant #DE-SC0008024 during the period June 2012 – March 2015. We focused on one of the main HEP research thrusts at the Energy Frontier by participating in the CMS experiment. We were exploiting the tremendous physics opportunities at the Large Hadron Collider (LHC) and prepared for physics at its planned extension, the High-Luminosity LHC. The effort comprised a physics component with analysis of data from the first LHC run and contributions to the CMS Phase-2 upgrades in the muon endcap system (EMU) formore » the High-Luminosity LHC. The emphasis of our hardware work was the development of large-area Gas Electron Multipliers (GEMs) for the CMS forward muon upgrade. We built a production and testing site for such detectors at Florida Tech to complement future chamber production at CERN. The first full-scale CMS GE1/1 chamber prototype ever built outside of CERN was constructed at Florida Tech in summer 2013. We conducted two beam tests with GEM prototype chambers at CERN in 2012 and at FNAL in 2013 and reported the results at conferences and in publications. Principal Investigator Hohlmann served as chair of the collaboration board of the CMS GEM collaboration and as co-coordinator of the GEM detector working group. He edited and authored sections of the detector chapter of the Technical Design Report (TDR) for the GEM muon upgrade, which was approved by the LHCC and the CERN Research Board in 2015. During the course of the TDR approval process, the GEM project was also established as an official subsystem of the muon system by the CMS muon institution board. On the physics side, graduate student Kalakhety performed a Z' search in the dimuon channel with the 2011 and 2012 CMS datasets that utilized 20.6 fb⁻¹ of p-p collisions at √s = 8 TeV. For the dimuon channel alone, the 95% CL lower limits obtained on the mass of a Z' resonance are 2770 GeV for a Z' with the same standard-model couplings as the Z boson. Our student team operated a Tier-3 cluster on the Open Science Grid (OSG) to support local CMS physics analysis and remote OSG activity. As a service to the HEP community, Hohlmann participated in the Snowmass effort over the course of 2013. Specifically, he acted as a liaison for gaseous detectors between the Instrumentation Frontier and the Energy Frontier and contributed to five papers and reports submitted to the summer study.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sirunyan, Albert M; et al.
The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energymore » $$\\sqrt{s}=$$ 13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously.« less
CuOF: an electrical to optical interface for the upgrade of the CMS muon Drift Tubes system
NASA Astrophysics Data System (ADS)
Dattola, D.; De Remigis, P.; Maselli, S.; Mazza, G.; Rotondo, F.; Wheadon, R.
2013-02-01
The upgrade of the Drift Tube system of the CMS experiment foresee the relocation of the electronics actually sitting on the racks beside the magnet from the cavern to the counting room. It is thus required to convert the signals from electrical to optical, for a total number of 3500 channels that run at up to 480 Mb/s. A Copper to Optical Fiber board is currently under design. The board is divided into a mother board, which hosts the slow control system based on Field Programmable Gate Array, and four mezzanine cards, each with 8 conversion channels. A prototype of the mezzanine board has been designed and tested under irradiation.
A time-resolved image sensor for tubeless streak cameras
NASA Astrophysics Data System (ADS)
Yasutomi, Keita; Han, SangMan; Seo, Min-Woong; Takasawa, Taishi; Kagawa, Keiichiro; Kawahito, Shoji
2014-03-01
This paper presents a time-resolved CMOS image sensor with draining-only modulation (DOM) pixels for tube-less streak cameras. Although the conventional streak camera has high time resolution, the device requires high voltage and bulky system due to the structure with a vacuum tube. The proposed time-resolved imager with a simple optics realize a streak camera without any vacuum tubes. The proposed image sensor has DOM pixels, a delay-based pulse generator, and a readout circuitry. The delay-based pulse generator in combination with an in-pixel logic allows us to create and to provide a short gating clock to the pixel array. A prototype time-resolved CMOS image sensor with the proposed pixel is designed and implemented using 0.11um CMOS image sensor technology. The image array has 30(Vertical) x 128(Memory length) pixels with the pixel pitch of 22.4um. .
42 CFR 488.417 - Denial of payment for all new admissions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... to CMS (for all facilities except non-State operated NFs against which CMS is imposing no remedies) or the State (for non-State operated NFs against which CMS is imposing no remedies); and (2) CMS (for all facilities except non-State operated NFs against which CMS is imposing no remedies) or the State...
42 CFR 488.417 - Denial of payment for all new admissions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... to CMS (for all facilities except non-State operated NFs against which CMS is imposing no remedies) or the State (for non-State operated NFs against which CMS is imposing no remedies); and (2) CMS (for all facilities except non-State operated NFs against which CMS is imposing no remedies) or the State...
42 CFR 488.417 - Denial of payment for all new admissions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... to CMS (for all facilities except non-State operated NFs against which CMS is imposing no remedies) or the State (for non-State operated NFs against which CMS is imposing no remedies); and (2) CMS (for all facilities except non-State operated NFs against which CMS is imposing no remedies) or the State...
42 CFR 488.417 - Denial of payment for all new admissions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... to CMS (for all facilities except non-State operated NFs against which CMS is imposing no remedies) or the State (for non-State operated NFs against which CMS is imposing no remedies); and (2) CMS (for all facilities except non-State operated NFs against which CMS is imposing no remedies) or the State...
42 CFR 488.417 - Denial of payment for all new admissions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... to CMS (for all facilities except non-State operated NFs against which CMS is imposing no remedies) or the State (for non-State operated NFs against which CMS is imposing no remedies); and (2) CMS (for all facilities except non-State operated NFs against which CMS is imposing no remedies) or the State...
45 CFR 150.317 - Factors CMS uses to determine the amount of penalty.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 1 2010-10-01 2010-10-01 false Factors CMS uses to determine the amount of... RELATING TO HEALTH CARE ACCESS CMS ENFORCEMENT IN GROUP AND INDIVIDUAL INSURANCE MARKETS CMS Enforcement With Respect to Issuers and Non-Federal Governmental Plans-Civil Money Penalties § 150.317 Factors CMS...
40 CFR Table 1 to Subpart Qqqqq of... - Applicability of General Provisions to Subpart QQQQQ
Code of Federal Regulations, 2010 CFR
2010-07-01
.... § 63.8(e) CMS Performance Evaluation No Subpart QQQQQ does not require CMS performance evaluations... QQQQQ does not require performance tests or CMS performance evaluations. § 63.9(e) Notification of... CMS No Subpart QQQQQ does not require CMS performance evaluations. § 63.10(a), (b), (d)(1), (d)(4)-(5...
42 CFR 422.510 - Termination of contract by CMS.
Code of Federal Regulations, 2010 CFR
2010-10-01
... (CONTINUED) MEDICARE PROGRAM MEDICARE ADVANTAGE PROGRAM Application Procedures and Contracts for Medicare Advantage Organizations § 422.510 Termination of contract by CMS. (a) Termination by CMS. CMS may at any...
NASA Technical Reports Server (NTRS)
Lacovara, R. C.
1990-01-01
The notions, benefits, and drawbacks of numeric simulation are introduced. Two formal simulation languages, Simpscript and Modsim are introduced. The capabilities of each are discussed briefly, and then the two programs are compared. The use of simulation in the process of design engineering for the Control and Monitoring System (CMS) for Space Station Freedom is discussed. The application of the formal simulation language to the CMS design is presented, and recommendations are made as to their use.
RHELP (Regenerative High Efficiency Low Pressure) Air Purification System
2009-06-18
with both SiC tubes and the fine granules was done by measuring THC concentration in the outlet air with the THC analyzer. When this was repeated...2.0 cm/s and 96.0% at 3.0 cm/s. This is close to what was seen originally without the plug. These results indicate that using THC concentration of...ratios of TB:AA from 1:0 to 1:16. ........ 34 Figure 25: df and Cv of samples with different PVP and F108 concentrations
Zhao, Qi; Wang, Xijie; Wang, Shuyan; Song, Zheng; Wang, Jiaxian; Ma, Jing
2017-03-09
Cardiotoxicity remains an important concern in drug discovery. Human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) have become an attractive platform to evaluate cardiotoxicity. However, the consistency between human embryonic stem cell-derived cardiomyocytes (hESC-CMs) and human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) in prediction of cardiotoxicity has yet to be elucidated. Here we screened the toxicities of four representative drugs (E-4031, isoprenaline, quinidine, and haloperidol) using both hESC-CMs and hiPSC-CMs, combined with an impedance-based bioanalytical method. It showed that both hESC-CMs and hiPSC-CMs can recapitulate cardiotoxicity and identify the effects of well-characterized compounds. The combined platform of hPSC-CMs and an impedance-based bioanalytical method could improve preclinical cardiotoxicity screening, holding great potential for increasing drug development accuracy.
Wei, Sheng; Ji, Xiao-wei; Wu, Chun-ling; Li, Zi-fa; Sun, Peng; Wang, Jie-qiong; Zhao, Qi-tao; Gao, Jie; Guo, Ying-hui; Sun, Shi-guang; Qiao, Ming-qi
2014-01-01
Background Accumulating epidemiological evidence shows that life event stressors are major vulnerability factors for psychiatric diseases such as major depression. It is also well known that the resident intruder paradigm (RIP) results in aggressive behavior in male rats. However, it is not known how resident intruder paradigm-induced aggression affects depressive-like behavior in isolated male rats subjected to chronic mild stress (CMS), which is an animal model of depression. Material/Methods Male Wistar rats were divided into 3 groups: non-stressed controls, isolated rats subjected to the CMS protocol, and resident intruder paradigm-exposed rats subjected to the CMS protocol. Results In the sucrose intake test, ingestion of a 1% sucrose solution by rats in the CMS group was significantly lower than in control and CMS+RIP rats after 3 weeks of stress. In the open-field test, CMS rats had significantly lower open-field scores compared to control rats. Furthermore, the total scores given the CMS group were significantly lower than in the CMS+RIP rats. In the forced swimming test (FST), the immobility times of CMS rats were significantly longer than those of the control or CMS+RIP rats. However, no differences were observed between controls and CMS+RIP rats. Conclusions Our data show that aggressive behavior evoked by the resident intruder paradigm could relieve broad-spectrum depressive-like behaviors in isolated adult male rats subjected to CMS. PMID:24911067
42 CFR 426.415 - CMS' role in the LCD review.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false CMS' role in the LCD review. 426.415 Section 426... Review of an LCD § 426.415 CMS' role in the LCD review. CMS may provide to the ALJ, and all parties to the LCD review, information identifying the person who represents the contractor or CMS, if necessary...
2015-10-30
Coastal Inlets Research Program CMS -Wave CMS -Wave is a two-dimensional spectral wind-wave generation and transformation model that employs a forward...marching, finite-difference method to solve the wave action conservation equation. Capabilities of CMS -Wave include wave shoaling, refraction... CMS -Wave can be used in either on a half- or full-plane mode, with primary waves propagating from the seaward boundary toward shore. It can
Liu, Taoyan; Huang, Chengwu; Li, Hongxia; Wu, Fujian; Luo, Jianwen; Lu, Wenjing
2018-01-01
The use of human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) is limited in drug discovery and cardiac disease mechanism studies due to cell immaturity. Although many approaches have been reported to improve the maturation of hiPSC-CMs, the elucidation of the process of maturation is crucial. We applied a small-molecule-based differentiation method to generate cardiomyocytes (CMs) with multiple aggregation forms. The motion analysis revealed significant physical differences in the differently shaped CMs, and the net-shaped CMs had larger motion amplitudes and faster velocities than the sheet-shaped CMs. The net-shaped CMs displayed accelerated maturation at the transcriptional level and were more similar to CMs with a prolonged culture time (30 days) than to sheet-d15. Ion channel genes and gap junction proteins were up-regulated in net-shaped CMs, indicating that robust contraction was coupled with enhanced ion channel and connexin expression. The net-shaped CMs also displayed improved myofibril ultrastructure under transmission electron microscopy. In conclusion, different multicellular hPSC-CM structures, such as the net-shaped pattern, are formed using the conditioned induction method, providing a useful tool to improve cardiac maturation. PMID:29661985
42 CFR 433.110 - Basis, purpose, and applicability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... and Information Retrieval Systems § 433.110 Basis, purpose, and applicability. (a) This subpart... information retrieval systems and for the operation of certain systems. Additional HHS regulations and CMS... conditions on mechanized claims processing and information retrieval systems (including eligibility...
42 CFR 433.110 - Basis, purpose, and applicability.
Code of Federal Regulations, 2012 CFR
2012-10-01
... and Information Retrieval Systems § 433.110 Basis, purpose, and applicability. (a) This subpart... information retrieval systems and for the operation of certain systems. Additional HHS regulations and CMS... conditions on mechanized claims processing and information retrieval systems (including eligibility...
42 CFR 433.110 - Basis, purpose, and applicability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... and Information Retrieval Systems § 433.110 Basis, purpose, and applicability. (a) This subpart... information retrieval systems and for the operation of certain systems. Additional HHS regulations and CMS... conditions on mechanized claims processing and information retrieval systems (including eligibility...
42 CFR 433.110 - Basis, purpose, and applicability.
Code of Federal Regulations, 2013 CFR
2013-10-01
... and Information Retrieval Systems § 433.110 Basis, purpose, and applicability. (a) This subpart... information retrieval systems and for the operation of certain systems. Additional HHS regulations and CMS... conditions on mechanized claims processing and information retrieval systems (including eligibility...
Human renal adipose tissue induces the invasion and progression of renal cell carcinoma.
Campo-Verde-Arbocco, Fiorella; López-Laur, José D; Romeo, Leonardo R; Giorlando, Noelia; Bruna, Flavia A; Contador, David E; López-Fontana, Gastón; Santiano, Flavia E; Sasso, Corina V; Zyla, Leila E; López-Fontana, Constanza M; Calvo, Juan C; Carón, Rubén W; Creydt, Virginia Pistone
2017-11-07
We evaluated the effects of conditioned media (CMs) of human adipose tissue from renal cell carcinoma located near the tumor (hRATnT) or farther away from the tumor (hRATfT), on proliferation, adhesion and migration of tumor (786-O and ACHN) and non-tumor (HK-2) human renal epithelial cell lines. Human adipose tissues were obtained from patients with renal cell carcinoma (RCC) and CMs from hRATnT and hRATfT incubation. Proliferation, adhesion and migration were quantified in 786-O, ACHN and HK-2 cell lines incubated with hRATnT-, hRATfT- or control-CMs. We evaluated versican, adiponectin and leptin expression in CMs from hRATnT and hRATfT. We evaluated AdipoR1/2, ObR, pERK, pAkt y pPI3K expression on cell lines incubated with CMs. No differences in proliferation of cell lines was found after 24 h of treatment with CMs. All cell lines showed a significant decrease in cell adhesion and increase in cell migration after incubation with hRATnT-CMs vs. hRATfT- or control-CMs. hRATnT-CMs showed increased levels of versican and leptin, compared to hRATfT-CMs. AdipoR2 in 786-O and ACHN cells decreased significantly after incubation with hRATfT- and hRATnT-CMs vs. control-CMs. We observed a decrease in the expression of pAkt in HK-2, 786-O and ACHN incubated with hRATnT-CMs. This result could partially explain the observed changes in migration and cell adhesion. We conclude that hRATnT released factors, such as leptin and versican, could enhance the invasive potential of renal epithelial cell lines and could modulate the progression of the disease.
Wu, Wei; Yao, Hang; Zhao, Helen W; Wang, Juan; Haddad, Gabriel G
2018-03-15
Chronic mountain sickness (CMS) or Monge's disease is a disease in highlanders. These patients have a variety of neurologic symptoms such as migraine, mental fatigue, confusion, dizziness, loss of appetite, memory loss and neuronal degeneration. The cellular and molecular mechanisms underlying CMS neuropathology is not understood. In the previous study, we demonstrated that neurons derived from CMS patients' fibroblasts have a decreased expression and altered gating properties of voltage-gated sodium channel. In this study, we further characterize the electrophysiological properties of iPSC-derived astrocytes from CMS patients. We found that the current densities of the inwardly rectifying potassium (Kir) channels in CMS astrocytes (-5.7 ± 2.2 pA/pF at -140 mV) were significantly decreased as compared to non-CMS (-28.4 ± 3.4 pA/pF at -140 mV) and sea level subjects (-28.3 ± 5.3 pA/pF at -140 mV). We further demonstrated that the reduced Kir current densities in CMS astrocytes were caused by their decreased protein expression of Kir4.1 and Kir2.3 channels, while single channel properties (i.e., P o , conductance) of Kir channel in CMS astrocytes were not altered. In addition, we found no significant differences of outward potassium currents between CMS and non-CMS astrocytes. As compared to non-CMS and sea level subjects, the K + uptake ability in CMS astrocytes was significantly decreased. Taken together, our results suggest that down-regulation of Kir channels and the resulting decreased K + uptake ability in astrocytes could be one of the major molecular mechanisms underlying the neurologic manifestations in CMS patients. Published by Elsevier Ltd.
Peinkofer, Gabriel; Burkert, Karsten; Urban, Katja; Krausgrill, Benjamin; Hescheler, Jürgen; Saric, Tomo; Halbach, Marcel
2016-10-01
Cardiomyocytes (CMs) derived from induced pluripotent stem cells (iPS-CMs) are promising candidates for cell therapy, drug screening, and developmental studies. It is known that iPS-CMs possess immature electrophysiological properties, but an exact characterization of their developmental stage and subtype differentiation is hampered by a lack of knowledge of electrophysiological properties of native CMs from different developmental stages and origins within the heart. Thus, we sought to systematically investigate action potential (AP) properties of native murine CMs and to establish a database that allows classification of stem cell-derived CMs. Hearts from 129S2PasCrl mice were harvested at days 9-10, 12-14, and 16-18 postcoitum, as well as 1 day, 3-4 days, 1-2 weeks, 3-4 weeks, and 6 weeks postpartum. AP recordings in left and right atria and at apical, medial, and basal left and right ventricles were performed with sharp glass microelectrodes. Measurements revealed significant changes in AP morphology during pre- and postnatal murine development and significant differences between atria and ventricles, enabling a classification of developmental stage and subtype differentiation of stem cell-derived CMs based on their AP properties. For iPS-CMs derived from cell line TiB7.4, a typical ventricular phenotype was demonstrated at later developmental stages, while there were electrophysiological differences from atrial as well as ventricular native CMs at earlier stages. This finding supports that iPS-CMs can develop AP properties similar to native CMs, but points to differences in the maturation process between iPS-CMs and native CMs, which may be explained by dissimilar conditions during in vitro differentiation and in vivo development.
Zhao, Miao; Wu, Xiao-Jie; Fan, Ya-Xin; Zhang, Ying-Yuan; Guo, Bei-Ning; Yu, Ji-Cheng; Cao, Guo-Ying; Chen, Yuan-Cheng; Wu, Ju-Fang; Shi, Yao-Guo; Li, Jian; Zhang, Jing
2018-05-01
The high prevalence of extensively drug-resistant Gram-negative pathogens has forced clinicians to use colistin as a last-line therapy. Knowledge on the pharmacokinetics of colistin methanesulfonate (CMS), an inactive prodrug, and colistin has increased substantially; however, the pharmacokinetics in the Chinese population is still unknown due to lack of a CMS product in China. This study aimed to evaluate the pharmacokinetics of a new CMS product developed in China in order to optimise dosing regimens. A total of 24 healthy subjects (12 female, 12 male) were enrolled in single- and multiple-dose pharmacokinetic (PK) studies. Concentrations of CMS and formed colistin in plasma and urine were measured, and PK analysis was conducted using a non-compartmental approach. Following a single CMS dose [2.36 mg colistin base activity (CBA) per kg, 1 h infusion], peak concentrations (C max ) of CMS and formed colistin were 18.0 mg/L and 0.661 mg/L, respectively. The estimated half-life (t 1/2 ) of CMS and colistin were 1.38 h and 4.49 h, respectively. Approximately 62.5% of the CMS dose was excreted via urine within 24 h after dosing, whilst only 1.28% was present in the form of colistin. Following multiple CMS doses, colistin reached steady-state within 24 h; there was no accumulation of CMS, but colistin accumulated slightly (R AUC = 1.33). This study provides the first PK data in the Chinese population and is essential for designing CMS dosing regimens for use in Chinese hospitals. The urinary PK data strongly support the use of intravenous CMS for serious urinary tract infections. Copyright © 2018 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.
Luque, Sònia; Grau, Santiago; Valle, Marta; Sorlí, Luisa; Horcajada, Juan Pablo; Segura, Concha; Alvarez-Lerma, Francisco
2013-08-01
Use of colistin has re-emerged for the treatment of infections caused by multidrug-resistant (MDR) Gram-negative bacteria, but information on its pharmacokinetics and pharmacodynamics is limited, especially in critically ill patients. Recent data from pharmacokinetic/pharmacodynamic (PK/PD) population studies have suggested that this population could benefit from administration of higher than standard doses of colistimethate sodium (CMS), but the relationship between administration of incremental doses of CMS and corresponding PK/PD parameters as well as its efficacy and toxicity have not yet been investigated in a clinical setting. The objective was to study the PK/PD differences of CMS and colistin between three different CMS dosage regimens in the same critically ill patient. A critically ill patient with nosocomial pneumonia caused by a MDR Acinetobacter baumannii received incremental doses of CMS. During administration of the different CMS dosage regimens, CMS and colistin plasma concentrations were determined and PK/PD indexes were calculated. With administration of the highest CMS dose once daily (720 mg every 24h), the peak plasma concentration of CMS and colistin increased to 40.51 mg/L and 1.81 mg/L, respectively, and the AUC0-24/MIC of colistin was 184.41. This dosage regimen was efficacious, and no nephrotoxicity or neurotoxicity was observed. In conclusion, a higher and extended-interval CMS dosage made it possible to increase the exposure of CMS and colistin in a critically ill patient infected by a MDR A. baumannii and allowed a clinical and microbiological optimal response to be achieved without evidence of toxicity. Copyright © 2013 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
Matrix light and pixel light: optical system architecture and requirements to the light source
NASA Astrophysics Data System (ADS)
Spinger, Benno; Timinger, Andreas L.
2015-09-01
Modern Automotive headlamps enable improved functionality for more driving comfort and safety. Matrix or Pixel light headlamps are not restricted to either pure low beam functionality or pure high beam. Light in direction of oncoming traffic is selectively switched of, potential hazard can be marked via an isolated beam and the illumination on the road can even follow a bend. The optical architectures that enable these advanced functionalities are diverse. Electromechanical shutters and lens units moved by electric motors were the first ways to realize these systems. Switching multiple LED light sources is a more elegant and mechanically robust solution. While many basic functionalities can already be realized with a limited number of LEDs, an increasing number of pixels will lead to more driving comfort and better visibility. The required optical system needs not only to generate a desired beam distribution with a high angular dynamic, but also needs to guarantee minimal stray light and cross talk between the different pixels. The direct projection of the LED array via a lens is a simple but not very efficient optical system. We discuss different optical elements for pre-collimating the light with minimal cross talk and improved contrast between neighboring pixels. Depending on the selected optical system, we derive the basic light source requirements: luminance, surface area, contrast, flux and color homogeneity.
George, David L; Smith, Michael J; Draugalis, JoLaine R; Tolma, Eleni L; Keast, Shellie L; Wilson, Justin B
2018-03-01
The Center for Medicare and Medicaid Services (CMS) created the Star Rating system based on multiple measures that indicate the overall quality of health plans. Community pharmacists can impact certain Star Ratings measure scores through medication adherence and patient safety interventions. To explore methods, needs, and workflow issues of community pharmacists to improve CMS Star Ratings measures. Think-aloud protocols (TAPs) were conducted with active community retail pharmacists in Oklahoma. Each TAP was audio recorded and transcribed to documents for analysis. Analysts agreed on common themes, illuminated differences in findings, and saturation of the data gathered. Methods, needs, and workflow themes of community pharmacists associated with improving Star Ratings measures were compiled and organized to exhibit a decision-making process. Five TAPs were performed among three independent pharmacy owners, one multi-store owner, and one chain-store administrator. A thematically common 4-step process to monitor and improve CMS Star Ratings scores among participants was identified. To improve Star Ratings measures, pharmacists: 1) used technology to access scores, 2) analyzed data to strategically set goals, 3) assessed individual patient information for comprehensive assessment, and 4) decided on interventions to best impact Star Ratings scores. Participants also shared common needs, workflow issues, and benefits associated with methods used in improving Star Ratings. TAPs were useful in exploring processes of pharmacists who improve CMS Star Ratings scores. Pharmacists demonstrated and verbalized their methods, workflow issues, needs, and benefits related to performing the task. The themes and decision-making process identified to improving CMS Star Ratings scores will assist in the development of training and education programs for pharmacists in the community setting. Published by Elsevier Inc.
Elastic Extension of a CMS Computing Centre Resources on External Clouds
NASA Astrophysics Data System (ADS)
Codispoti, G.; Di Maria, R.; Aiftimiei, C.; Bonacorsi, D.; Calligola, P.; Ciaschini, V.; Costantini, A.; Dal Pra, S.; DeGirolamo, D.; Grandi, C.; Michelotto, D.; Panella, M.; Peco, G.; Sapunenko, V.; Sgaravatto, M.; Taneja, S.; Zizzi, G.
2016-10-01
After the successful LHC data taking in Run-I and in view of the future runs, the LHC experiments are facing new challenges in the design and operation of the computing facilities. The computing infrastructure for Run-II is dimensioned to cope at most with the average amount of data recorded. The usage peaks, as already observed in Run-I, may however originate large backlogs, thus delaying the completion of the data reconstruction and ultimately the data availability for physics analysis. In order to cope with the production peaks, CMS - along the lines followed by other LHC experiments - is exploring the opportunity to access Cloud resources provided by external partners or commercial providers. Specific use cases have already been explored and successfully exploited during Long Shutdown 1 (LS1) and the first part of Run 2. In this work we present the proof of concept of the elastic extension of a CMS site, specifically the Bologna Tier-3, on an external OpenStack infrastructure. We focus on the “Cloud Bursting” of a CMS Grid site using a newly designed LSF configuration that allows the dynamic registration of new worker nodes to LSF. In this approach, the dynamically added worker nodes instantiated on the OpenStack infrastructure are transparently accessed by the LHC Grid tools and at the same time they serve as an extension of the farm for the local usage. The amount of resources allocated thus can be elastically modeled to cope up with the needs of CMS experiment and local users. Moreover, a direct access/integration of OpenStack resources to the CMS workload management system is explored. In this paper we present this approach, we report on the performances of the on-demand allocated resources, and we discuss the lessons learned and the next steps.
Demonstration of a real-time implementation of the ICVision holographic stereogram display
NASA Astrophysics Data System (ADS)
Kulick, Jeffrey H.; Jones, Michael W.; Nordin, Gregory P.; Lindquist, Robert G.; Kowel, Stephen T.; Thomsen, Axel
1995-07-01
There is increasing interest in real-time autostereoscopic 3D displays. Such systems allow 3D objects or scenes to be viewed by one or more observers with correct motion parallax without the need for glasses or other viewing aids. Potential applications of such systems include mechanical design, training and simulation, medical imaging, virtual reality, and architectural design. One approach to the development of real-time autostereoscopic display systems has been to develop real-time holographic display systems. The approach taken by most of the systems is to compute and display a number of holographic lines at one time, and then use a scanning system to replicate the images throughout the display region. The approach taken in the ICVision system being developed at the University of Alabama in Huntsville is very different. In the ICVision display, a set of discrete viewing regions called virtual viewing slits are created by the display. Each pixel is required fill every viewing slit with different image data. When the images presented in two virtual viewing slits separated by an interoccular distance are filled with stereoscopic pair images, the observer sees a 3D image. The images are computed so that a different stereo pair is presented each time the viewer moves 1 eye pupil diameter (approximately mm), thus providing a series of stereo views. Each pixel is subdivided into smaller regions, called partial pixels. Each partial pixel is filled with a diffraction grating that is just that required to fill an individual virtual viewing slit. The sum of all the partial pixels in a pixel then fill all the virtual viewing slits. The final version of the ICVision system will form diffraction gratings in a liquid crystal layer on the surface of VLSI chips in real time. Processors embedded in the VLSI chips will compute the display in real- time. In the current version of the system, a commercial AMLCD is sandwiched with a diffraction grating array. This paper will discuss the design details of a protable 3D display based on the integration of a diffractive optical element with a commercial off-the-shelf AMLCD. The diffractive optic contains several hundred thousand partial-pixel gratings and the AMLCD modulates the light diffracted by the gratings.
Structural and Functional Maturation of Cardiomyocytes Derived from Human Pluripotent Stem Cells
Lundy, Scott D.; Zhu, Wei-Zhong
2013-01-01
Despite preclinical studies demonstrating the functional benefit of transplanting human pluripotent stem cell-derived cardiomyocytes (PSC-CMs) into damaged myocardium, the ability of these immature cells to adopt a more adult-like cardiomyocyte (CM) phenotype remains uncertain. To address this issue, we tested the hypothesis that prolonged in vitro culture of human embryonic stem cell (hESC)- and human induced pluripotent stem cell (hiPSC)-derived CMs would result in the maturation of their structural and contractile properties to a more adult-like phenotype. Compared to their early-stage counterparts (PSC-CMs after 20–40 days of in vitro differentiation and culture), late-stage hESC-CMs and hiPSC-CMs (80–120 days) showed dramatic differences in morphology, including increased cell size and anisotropy, greater myofibril density and alignment, sarcomeres visible by bright-field microscopy, and a 10-fold increase in the fraction of multinucleated CMs. Ultrastructural analysis confirmed improvements in the myofibrillar density, alignment, and morphology. We measured the contractile performance of late-stage hESC-CMs and hiPSC-CMs and noted a doubling in shortening magnitude with slowed contraction kinetics compared to the early-stage cells. We then examined changes in the calcium-handling properties of these matured CMs and found an increase in calcium release and reuptake rates with no change in the maximum amplitude. Finally, we performed electrophysiological assessments in hESC-CMs and found that late-stage myocytes have hyperpolarized maximum diastolic potentials, increased action potential amplitudes, and faster upstroke velocities. To correlate these functional changes with gene expression, we performed qPCR and found a robust induction of the key cardiac structural markers, including β-myosin heavy chain and connexin-43, in late-stage hESC-CMs and hiPSC-CMs. These findings suggest that PSC-CMs are capable of slowly maturing to more closely resemble the phenotype of adult CMs and may eventually possess the potential to regenerate the lost myocardium with robust de novo force-producing tissue. PMID:23461462
NASA Astrophysics Data System (ADS)
Balcas, J.; Bockelman, B.; Gardner, R., Jr.; Hurtado Anampa, K.; Jayatilaka, B.; Aftab Khan, F.; Lannon, K.; Larson, K.; Letts, J.; Marra Da Silva, J.; Mascheroni, M.; Mason, D.; Perez-Calero Yzquierdo, A.; Tiradani, A.
2017-10-01
The CMS experiment collects and analyzes large amounts of data coming from high energy particle collisions produced by the Large Hadron Collider (LHC) at CERN. This involves a huge amount of real and simulated data processing that needs to be handled in batch-oriented platforms. The CMS Global Pool of computing resources provide +100K dedicated CPU cores and another 50K to 100K CPU cores from opportunistic resources for these kind of tasks and even though production and event processing analysis workflows are already managed by existing tools, there is still a lack of support to submit final stage condor-like analysis jobs familiar to Tier-3 or local Computing Facilities users into these distributed resources in an integrated (with other CMS services) and friendly way. CMS Connect is a set of computing tools and services designed to augment existing services in the CMS Physics community focusing on these kind of condor analysis jobs. It is based on the CI-Connect platform developed by the Open Science Grid and uses the CMS GlideInWMS infrastructure to transparently plug CMS global grid resources into a virtual pool accessed via a single submission machine. This paper describes the specific developments and deployment of CMS Connect beyond the CI-Connect platform in order to integrate the service with CMS specific needs, including specific Site submission, accounting of jobs and automated reporting to standard CMS monitoring resources in an effortless way to their users.
Dong, Xiangshu; Kim, Wan Kyu; Lim, Yong-Pyo; Kim, Yeon-Ki; Hur, Yoonkang
2013-02-01
We investigated the mechanism regulating cytoplasmic male sterility (CMS) in Brassica rapa ssp. pekinensis using floral bud transcriptome analyses of Ogura-CMS Chinese cabbage and its maintainer line in B. rapa 300-K oligomeric probe (Br300K) microarrays. Ogura-CMS Chinese cabbage produced few and infertile pollen grains on indehiscent anthers. Compared to the maintainer line, CMS plants had shorter filaments and plant growth, and delayed flowering and pollen development. In microarray analysis, 4646 genes showed different expression, depending on floral bud size, between Ogura-CMS and its maintainer line. We found 108 and 62 genes specifically expressed in Ogura-CMS and its maintainer line, respectively. Ogura-CMS line-specific genes included stress-related, redox-related, and B. rapa novel genes. In the maintainer line, genes related to pollen coat and germination were specifically expressed in floral buds longer than 3mm, suggesting insufficient expression of these genes in Ogura-CMS is directly related to dysfunctional pollen. In addition, many nuclear genes associated with auxin response, ATP synthesis, pollen development and stress response had delayed expression in Ogura-CMS plants compared to the maintainer line, which is consistent with the delay in growth and development of Ogura-CMS plants. Delayed expression may reduce pollen grain production and/or cause sterility, implying that mitochondrial, retrograde signaling delays nuclear gene expression. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Chiou, Yi-Ling; Chen, Ying-Jung; Lin, Shinne-Ren; Chang, Long-Sen
2011-11-01
CMS-9, a phospholipase A(2) (PLA(2)) from Naja nigricollis venom, induced the death of human breast cancer MCF-7 cells accompanied with the formation of cell clumps without clear boundaries between cells. Annexin V-FITC staining indicated that abundant phosphatidylserine appeared on the outer membrane of MCF-7 cell clumps, implying the possibility that CMS-9 may promote membrane fusion via anionic phospholipids. To validate this proposition, fusogenic activity of CMS-9 on vesicles composed of zwitterionic phospholipid alone or a combination of zwitterionic and anionic phospholipids was examined. Although CMS-9-induced fusion of zwitterionic phospholipid vesicles depended on PLA(2) activity, CMS-9-induced fusion of vesicles containing anionic phospholipids could occur without the involvement of PLA(2) activity. Membrane-damaging activity of CMS-9 was associated with its fusogenicity. Moreover, CMS-9 induced differently membrane leakage and membrane fusion of vesicles with different compositions. Membrane fluidity and binding capability with phospholipid vesicles were not related to the fusogenicity of CMS-9. However, membrane-bound conformation and mode of CMS-9 depended on phospholipid compositions. Collectively, our data suggest that PLA(2) activity-dependent and -independent fusogenicity of CMS-9 are closely related to its membrane-bound modes and targeted membrane compositions. Copyright © 2011 Elsevier Ltd. All rights reserved.
Pushing HTCondor and glideinWMS to 200K+ Jobs in a Global Pool for CMS before Run 2
NASA Astrophysics Data System (ADS)
Balcas, J.; Belforte, S.; Bockelman, B.; Gutsche, O.; Khan, F.; Larson, K.; Letts, J.; Mascheroni, M.; Mason, D.; McCrea, A.; Saiz-Santos, M.; Sfiligoi, I.
2015-12-01
The CMS experiment at the LHC relies on HTCondor and glideinWMS as its primary batch and pilot-based Grid provisioning system. So far we have been running several independent resource pools, but we are working on unifying them all to reduce the operational load and more effectively share resources between various activities in CMS. The major challenge of this unification activity is scale. The combined pool size is expected to reach 200K job slots, which is significantly bigger than any other multi-user HTCondor based system currently in production. To get there we have studied scaling limitations in our existing pools, the biggest of which tops out at about 70K slots, providing valuable feedback to the development communities, who have responded by delivering improvements which have helped us reach higher and higher scales with more stability. We have also worked on improving the organization and support model for this critical service during Run 2 of the LHC. This contribution will present the results of the scale testing and experiences from the first months of running the Global Pool.
42 CFR 411.382 - CMS's right to rescind advisory opinions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... rescind advisory opinions. Any advice CMS gives in an opinion does not prejudice its right to reconsider... faith reliance upon CMS's advice under this part, provided— (a) The requestor presented to CMS a full...
42 CFR 411.382 - CMS's right to rescind advisory opinions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... rescind advisory opinions. Any advice CMS gives in an opinion does not prejudice its right to reconsider... faith reliance upon CMS's advice under this part, provided— (a) The requestor presented to CMS a full...
Kim, Hwa Sun; Cho, Hune; Lee, In Keun
2011-06-01
We design and develop an electronic claim system based on an integrated electronic health record (EHR) platform. This system is designed to be used for ambulatory care by office-based physicians in the United States. This is achieved by integrating various medical standard technologies for interoperability between heterogeneous information systems. The developed system serves as a simple clinical data repository, it automatically fills out the Centers for Medicare and Medicaid Services (CMS)-1500 form based on information regarding the patients and physicians' clinical activities. It supports electronic insurance claims by creating reimbursement charges. It also contains an HL7 interface engine to exchange clinical messages between heterogeneous devices. The system partially prevents physician malpractice by suggesting proper treatments according to patient diagnoses and supports physicians by easily preparing documents for reimbursement and submitting claim documents to insurance organizations electronically, without additional effort by the user. To show the usability of the developed system, we performed an experiment that compares the time spent filling out the CMS-1500 form directly and time required create electronic claim data using the developed system. From the experimental results, we conclude that the system could save considerable time for physicians in making claim documents. The developed system might be particularly useful for those who need a reimbursement-specialized EHR system, even though the proposed system does not completely satisfy all criteria requested by the CMS and Office of the National Coordinator for Health Information Technology (ONC). This is because the criteria are not sufficient but necessary condition for the implementation of EHR systems. The system will be upgraded continuously to implement the criteria and to offer more stable and transparent transmission of electronic claim data.
75 FR 82372 - Application(s) for Duty-Free Entry of Scientific Instruments
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-30
..., Argonne LLC, 9700 South Cass Ave., Lemont, IL 60439. Instrument: Pilatus 100K Pixel Detector System... efficiency (no readout noise and direct detection scheme), high dynamic range (20-bits), and fast readout.... Instrument: Pilatus 300K Pixel Detector System. Manufacturer: Dectris Ltd., Switzerland. Intended Use: The...
42 CFR 433.110 - Basis, purpose, and applicability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... and Information Retrieval Systems § 433.110 Basis, purpose, and applicability. (a) This subpart... information retrieval systems and for the operation of certain systems. Additional HHS regulations and CMS... mechanized claims processing and information retrieval system or if the system fails to meet certain...
Chatrchyan, Serguei
2014-02-20
Azimuthal dihadron correlations of charged particles have been measured in PbPb collisions atmore » $$\\sqrt{s_{NN}}$$ = 2.76 TeV by the CMS collaboration, using data from the 2011 LHC heavy-ion run. The data set includes a sample of ultra-central (0-0.2% centrality) PbPb events collected using a trigger based on total transverse energy in the hadron forward calorimeters and the total multiplicity of pixel clusters in the silicon pixel tracker. A total of about 1.8 million ultra-central events were recorded, corresponding to an integrated luminosity of 120 inverse microbarns. The observed correlations in ultra-central PbPb events are expected to be particularly sensitive to initial-state fluctuations. The single-particle anisotropy Fourier harmonics, from $$v_2$$ to $$v_6$$, are extracted as a function of particle transverse momentum. At higher transverse momentum, the $$v_2$$ harmonic becomes significantly smaller than the higher-order $$v_n$$ (n greater than or equal to 3). The pt-averaged $$v_2$$ and $$v_3$$ are found to be equal within 2%, while higher-order $$v_n$$ decrease as n increases. The breakdown of factorization of dihadron correlations into single-particle azimuthal anisotropies is observed. This effect is found to be most prominent in the ultra-central PbPb collisions, where the initial-state fluctuations play a dominant role. As a result, a comparison of the factorization data to hydrodynamic predictions with event-by-event fluctuating initial conditions is also presented.« less
Faxed document image restoration method based on local pixel patterns
NASA Astrophysics Data System (ADS)
Akiyama, Teruo; Miyamoto, Nobuo; Oguro, Masami; Ogura, Kenji
1998-04-01
A method for restoring degraded faxed document images using the patterns of pixels that construct small areas in a document is proposed. The method effectively restores faxed images that contain the halftone textures and/or density salt-and-pepper noise that degrade OCR system performance. The halftone image restoration process, white-centered 3 X 3 pixels, in which black-and-white pixels alternate, are identified first using the distribution of the pixel values as halftone textures, and then the white center pixels are inverted to black. To remove high-density salt- and-pepper noise, it is assumed that the degradation is caused by ill-balanced bias and inappropriate thresholding of the sensor output which results in the addition of random noise. Restored image can be estimated using an approximation that uses the inverse operation of the assumed original process. In order to process degraded faxed images, the algorithms mentioned above are combined. An experiment is conducted using 24 especially poor quality examples selected from data sets that exemplify what practical fax- based OCR systems cannot handle. The maximum recovery rate in terms of mean square error was 98.8 percent.
Heng, Shuangping; Wei, Chao; Jing, Bing; Wan, Zhengjie; Wen, Jing; Yi, Bin; Ma, Chaozhi; Tu, Jinxing; Fu, Tingdong; Shen, Jinxiong
2014-04-30
Cytoplasmic male sterility (CMS) is not only important for exploiting heterosis in crop plants, but also as a model for investigating nuclear-cytoplasmic interaction. CMS may be caused by mutations, rearrangement or recombination in the mitochondrial genome. Understanding the mitochondrial genome is often the first and key step in unraveling the molecular and genetic basis of CMS in plants. Comparative analysis of the mitochondrial genome of the hau CMS line and its maintainer line in B. juneca (Brassica juncea) may help show the origin of the CMS-associated gene orf288. Through next-generation sequencing, the B. juncea hau CMS mitochondrial genome was assembled into a single, circular-mapping molecule that is 247,903 bp in size and 45.08% in GC content. In addition to the CMS associated gene orf288, the genome contains 35 protein-encoding genes, 3 rRNAs, 25 tRNA genes and 29 ORFs of unknown function. The mitochondrial genome sizes of the maintainer line and another normal type line "J163-4" are both 219,863 bp and with GC content at 45.23%. The maintainer line has 36 genes with protein products, 3 rRNAs, 22 tRNA genes and 31 unidentified ORFs. Comparative analysis the mitochondrial genomes of the hau CMS line and its maintainer line allowed us to develop specific markers to separate the two lines at the seedling stage. We also confirmed that different mitotypes coexist substoichiometrically in hau CMS lines and its maintainer lines in B. juncea. The number of repeats larger than 100 bp in the hau CMS line (16 repeats) are nearly twice of those found in the maintainer line (9 repeats). Phylogenetic analysis of the CMS-associated gene orf288 and four other homologous sequences in Brassicaceae show that orf288 was clearly different from orf263 in Brassica tournefortii despite of strong similarity. The hau CMS mitochondrial genome was highly rearranged when compared with its iso-nuclear maintainer line mitochondrial genome. This study may be useful for studying the mechanism of natural CMS in B. juncea, performing comparative analysis on sequenced mitochondrial genomes in Brassicas, and uncovering the origin of the hau CMS mitotype and structural and evolutionary differences between different mitotypes.
Opportunistic Resource Usage in CMS
NASA Astrophysics Data System (ADS)
Kreuzer, Peter; Hufnagel, Dirk; Dykstra, D.; Gutsche, O.; Tadel, M.; Sfiligoi, I.; Letts, J.; Wuerthwein, F.; McCrea, A.; Bockelman, B.; Fajardo, E.; Linares, L.; Wagner, R.; Konstantinov, P.; Blumenfeld, B.; Bradley, D.; Cms Collaboration
2014-06-01
CMS is using a tiered setup of dedicated computing resources provided by sites distributed over the world and organized in WLCG. These sites pledge resources to CMS and are preparing them especially for CMS to run the experiment's applications. But there are more resources available opportunistically both on the GRID and in local university and research clusters which can be used for CMS applications. We will present CMS' strategy to use opportunistic resources and prepare them dynamically to run CMS applications. CMS is able to run its applications on resources that can be reached through the GRID, through EC2 compliant cloud interfaces. Even resources that can be used through ssh login nodes can be harnessed. All of these usage modes are integrated transparently into the GlideIn WMS submission infrastructure, which is the basis of CMS' opportunistic resource usage strategy. Technologies like Parrot to mount the software distribution via CVMFS and xrootd for access to data and simulation samples via the WAN are used and will be described. We will summarize the experience with opportunistic resource usage and give an outlook for the restart of LHC data taking in 2015.
Parallel processor-based raster graphics system architecture
Littlefield, Richard J.
1990-01-01
An apparatus for generating raster graphics images from the graphics command stream includes a plurality of graphics processors connected in parallel, each adapted to receive any part of the graphics command stream for processing the command stream part into pixel data. The apparatus also includes a frame buffer for mapping the pixel data to pixel locations and an interconnection network for interconnecting the graphics processors to the frame buffer. Through the interconnection network, each graphics processor may access any part of the frame buffer concurrently with another graphics processor accessing any other part of the frame buffer. The plurality of graphics processors can thereby transmit concurrently pixel data to pixel locations in the frame buffer.
77 FR 41331 - Commercial Mobile Alert System
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-13
... Mobile Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of... with the Commission's Commercial Mobile Alert System (CMS), Second Report and Order (``CMAS Second... Alert System rules contained in the Commission's Second Report and Order, FCC 08- 164, published at 73...
Congestion Management System Process Report
DOT National Transportation Integrated Search
1996-03-01
In January 1995, the Indianapolis Metropolitan Planning Organization with the help of an interagency Study Review Committee began the process of developing a Congestion Management System (CMS) Plan resulting in this report. This report documents the ...
Improving the design of competitive bidding in Medicare Advantage.
Cawley, John H; Whitford, Andrew B
2007-04-01
In 2003, Congress passed the Medicare Prescription Drug, Improvement, and Modernization Act, which required that in 2006 the Centers for Medicare and Medicaid Services (CMS) implement a system of competitive bids to set payments for the Medicare Advantage program. Managed care plans now bid for the right to enroll Medicare beneficiaries. Data from the first year of bidding suggest that imperfect competition is limiting the success of the bidding system. This article offers suggestions to improve this system based on findings from auction theory and previous government-run auctions. In particular, CMS can benefit by adjusting its system of competitive bids in four ways: credibly committing to regulations governing bidding; limiting the scope for collusion, entry deterrence, and predatory behavior among bidders; adjusting how benchmark reimbursement rates are set; and accounting for asymmetric information among bidders.
Imaging properties of pixellated scintillators with deep pixels
Barber, H. Bradford; Fastje, David; Lemieux, Daniel; Grim, Gary P.; Furenlid, Lars R.; Miller, Brian W.; Parkhurst, Philip; Nagarkar, Vivek V.
2015-01-01
We have investigated the light-transport properties of scintillator arrays with long, thin pixels (deep pixels) for use in high-energy gamma-ray imaging. We compared 10×10 pixel arrays of YSO:Ce, LYSO:Ce and BGO (1mm × 1mm × 20 mm pixels) made by Proteus, Inc. with similar 10×10 arrays of LSO:Ce and BGO (1mm × 1mm × 15mm pixels) loaned to us by Saint-Gobain. The imaging and spectroscopic behaviors of these scintillator arrays are strongly affected by the choice of a reflector used as an inter-pixel spacer (3M ESR in the case of the Proteus arrays and white, diffuse-reflector for the Saint-Gobain arrays). We have constructed a 3700-pixel LYSO:Ce Prototype NIF Gamma-Ray Imager for use in diagnosing target compression in inertial confinement fusion. This system was tested at the OMEGA Laser and exhibited significant optical, inter-pixel cross-talk that was traced to the use of a single-layer of ESR film as an inter-pixel spacer. We show how the optical cross-talk can be mapped, and discuss correction procedures. We demonstrate a 10×10 YSO:Ce array as part of an iQID (formerly BazookaSPECT) imager and discuss issues related to the internal activity of 176Lu in LSO:Ce and LYSO:Ce detectors. PMID:26236070
Imaging properties of pixellated scintillators with deep pixels
NASA Astrophysics Data System (ADS)
Barber, H. Bradford; Fastje, David; Lemieux, Daniel; Grim, Gary P.; Furenlid, Lars R.; Miller, Brian W.; Parkhurst, Philip; Nagarkar, Vivek V.
2014-09-01
We have investigated the light-transport properties of scintillator arrays with long, thin pixels (deep pixels) for use in high-energy gamma-ray imaging. We compared 10x10 pixel arrays of YSO:Ce, LYSO:Ce and BGO (1mm x 1mm x 20 mm pixels) made by Proteus, Inc. with similar 10x10 arrays of LSO:Ce and BGO (1mm x 1mm x 15mm pixels) loaned to us by Saint-Gobain. The imaging and spectroscopic behaviors of these scintillator arrays are strongly affected by the choice of a reflector used as an inter-pixel spacer (3M ESR in the case of the Proteus arrays and white, diffuse-reflector for the Saint-Gobain arrays). We have constructed a 3700-pixel LYSO:Ce Prototype NIF Gamma-Ray Imager for use in diagnosing target compression in inertial confinement fusion. This system was tested at the OMEGA Laser and exhibited significant optical, inter-pixel cross-talk that was traced to the use of a single-layer of ESR film as an inter-pixel spacer. We show how the optical cross-talk can be mapped, and discuss correction procedures. We demonstrate a 10x10 YSO:Ce array as part of an iQID (formerly BazookaSPECT) imager and discuss issues related to the internal activity of 176Lu in LSO:Ce and LYSO:Ce detectors.
Multi-core processing and scheduling performance in CMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez, J. M.; Evans, D.; Foulkes, S.
2012-01-01
Commodity hardware is going many-core. We might soon not be able to satisfy the job memory needs per core in the current single-core processing model in High Energy Physics. In addition, an ever increasing number of independent and incoherent jobs running on the same physical hardware not sharing resources might significantly affect processing performance. It will be essential to effectively utilize the multi-core architecture. CMS has incorporated support for multi-core processing in the event processing framework and the workload management system. Multi-core processing jobs share common data in memory, such us the code libraries, detector geometry and conditions data, resultingmore » in a much lower memory usage than standard single-core independent jobs. Exploiting this new processing model requires a new model in computing resource allocation, departing from the standard single-core allocation for a job. The experiment job management system needs to have control over a larger quantum of resource since multi-core aware jobs require the scheduling of multiples cores simultaneously. CMS is exploring the approach of using whole nodes as unit in the workload management system where all cores of a node are allocated to a multi-core job. Whole-node scheduling allows for optimization of the data/workflow management (e.g. I/O caching, local merging) but efficient utilization of all scheduled cores is challenging. Dedicated whole-node queues have been setup at all Tier-1 centers for exploring multi-core processing workflows in CMS. We present the evaluation of the performance scheduling and executing multi-core workflows in whole-node queues compared to the standard single-core processing workflows.« less
Monitoring data transfer latency in CMS computing operations
Bonacorsi, Daniele; Diotalevi, Tommaso; Magini, Nicolo; ...
2015-12-23
During the first LHC run, the CMS experiment collected tens of Petabytes of collision and simulated data, which need to be distributed among dozens of computing centres with low latency in order to make efficient use of the resources. While the desired level of throughput has been successfully achieved, it is still common to observe transfer workflows that cannot reach full completion in a timely manner due to a small fraction of stuck files which require operator intervention.For this reason, in 2012 the CMS transfer management system, PhEDEx, was instrumented with a monitoring system to measure file transfer latencies, andmore » to predict the completion time for the transfer of a data set. The operators can detect abnormal patterns in transfer latencies while the transfer is still in progress, and monitor the long-term performance of the transfer infrastructure to plan the data placement strategy.Based on the data collected for one year with the latency monitoring system, we present a study on the different factors that contribute to transfer completion time. As case studies, we analyze several typical CMS transfer workflows, such as distribution of collision event data from CERN or upload of simulated event data from the Tier-2 centres to the archival Tier-1 centres. For each workflow, we present the typical patterns of transfer latencies that have been identified with the latency monitor.We identify the areas in PhEDEx where a development effort can reduce the latency, and we show how we are able to detect stuck transfers which need operator intervention. Lastly, we propose a set of metrics to alert about stuck subscriptions and prompt for manual intervention, with the aim of improving transfer completion times.« less
Monitoring data transfer latency in CMS computing operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonacorsi, Daniele; Diotalevi, Tommaso; Magini, Nicolo
During the first LHC run, the CMS experiment collected tens of Petabytes of collision and simulated data, which need to be distributed among dozens of computing centres with low latency in order to make efficient use of the resources. While the desired level of throughput has been successfully achieved, it is still common to observe transfer workflows that cannot reach full completion in a timely manner due to a small fraction of stuck files which require operator intervention.For this reason, in 2012 the CMS transfer management system, PhEDEx, was instrumented with a monitoring system to measure file transfer latencies, andmore » to predict the completion time for the transfer of a data set. The operators can detect abnormal patterns in transfer latencies while the transfer is still in progress, and monitor the long-term performance of the transfer infrastructure to plan the data placement strategy.Based on the data collected for one year with the latency monitoring system, we present a study on the different factors that contribute to transfer completion time. As case studies, we analyze several typical CMS transfer workflows, such as distribution of collision event data from CERN or upload of simulated event data from the Tier-2 centres to the archival Tier-1 centres. For each workflow, we present the typical patterns of transfer latencies that have been identified with the latency monitor.We identify the areas in PhEDEx where a development effort can reduce the latency, and we show how we are able to detect stuck transfers which need operator intervention. Lastly, we propose a set of metrics to alert about stuck subscriptions and prompt for manual intervention, with the aim of improving transfer completion times.« less
Web Proxy Auto Discovery for the WLCG
NASA Astrophysics Data System (ADS)
Dykstra, D.; Blomer, J.; Blumenfeld, B.; De Salvo, A.; Dewhurst, A.; Verguilov, V.
2017-10-01
All four of the LHC experiments depend on web proxies (that is, squids) at each grid site to support software distribution by the CernVM FileSystem (CVMFS). CMS and ATLAS also use web proxies for conditions data distributed through the Frontier Distributed Database caching system. ATLAS & CMS each have their own methods for their grid jobs to find out which web proxies to use for Frontier at each site, and CVMFS has a third method. Those diverse methods limit usability and flexibility, particularly for opportunistic use cases, where an experiment’s jobs are run at sites that do not primarily support that experiment. This paper describes a new Worldwide LHC Computing Grid (WLCG) system for discovering the addresses of web proxies. The system is based on an internet standard called Web Proxy Auto Discovery (WPAD). WPAD is in turn based on another standard called Proxy Auto Configuration (PAC). Both the Frontier and CVMFS clients support this standard. The input into the WLCG system comes from squids registered in the ATLAS Grid Information System (AGIS) and CMS SITECONF files, cross-checked with squids registered by sites in the Grid Configuration Database (GOCDB) and the OSG Information Management (OIM) system, and combined with some exceptions manually configured by people from ATLAS and CMS who operate WLCG Squid monitoring. WPAD servers at CERN respond to http requests from grid nodes all over the world with a PAC file that lists available web proxies, based on IP addresses matched from a database that contains the IP address ranges registered to organizations. Large grid sites are encouraged to supply their own WPAD web servers for more flexibility, to avoid being affected by short term long distance network outages, and to offload the WLCG WPAD servers at CERN. The CERN WPAD servers additionally support requests from jobs running at non-grid sites (particularly for LHC@Home) which they direct to the nearest publicly accessible web proxy servers. The responses to those requests are geographically ordered based on a separate database that maps IP addresses to longitude and latitude.
Web Proxy Auto Discovery for the WLCG
Dykstra, D.; Blomer, J.; Blumenfeld, B.; ...
2017-11-23
All four of the LHC experiments depend on web proxies (that is, squids) at each grid site to support software distribution by the CernVM FileSystem (CVMFS). CMS and ATLAS also use web proxies for conditions data distributed through the Frontier Distributed Database caching system. ATLAS & CMS each have their own methods for their grid jobs to find out which web proxies to use for Frontier at each site, and CVMFS has a third method. Those diverse methods limit usability and flexibility, particularly for opportunistic use cases, where an experiment’s jobs are run at sites that do not primarily supportmore » that experiment. This paper describes a new Worldwide LHC Computing Grid (WLCG) system for discovering the addresses of web proxies. The system is based on an internet standard called Web Proxy Auto Discovery (WPAD). WPAD is in turn based on another standard called Proxy Auto Configuration (PAC). Both the Frontier and CVMFS clients support this standard. The input into the WLCG system comes from squids registered in the ATLAS Grid Information System (AGIS) and CMS SITECONF files, cross-checked with squids registered by sites in the Grid Configuration Database (GOCDB) and the OSG Information Management (OIM) system, and combined with some exceptions manually configured by people from ATLAS and CMS who operate WLCG Squid monitoring. WPAD servers at CERN respond to http requests from grid nodes all over the world with a PAC file that lists available web proxies, based on IP addresses matched from a database that contains the IP address ranges registered to organizations. Large grid sites are encouraged to supply their own WPAD web servers for more flexibility, to avoid being affected by short term long distance network outages, and to offload the WLCG WPAD servers at CERN. The CERN WPAD servers additionally support requests from jobs running at non-grid sites (particularly for LHC@Home) which it directs to the nearest publicly accessible web proxy servers. Furthermore, the responses to those requests are geographically ordered based on a separate database that maps IP addresses to longitude and latitude.« less
Web Proxy Auto Discovery for the WLCG
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dykstra, D.; Blomer, J.; Blumenfeld, B.
All four of the LHC experiments depend on web proxies (that is, squids) at each grid site to support software distribution by the CernVM FileSystem (CVMFS). CMS and ATLAS also use web proxies for conditions data distributed through the Frontier Distributed Database caching system. ATLAS & CMS each have their own methods for their grid jobs to find out which web proxies to use for Frontier at each site, and CVMFS has a third method. Those diverse methods limit usability and flexibility, particularly for opportunistic use cases, where an experiment’s jobs are run at sites that do not primarily supportmore » that experiment. This paper describes a new Worldwide LHC Computing Grid (WLCG) system for discovering the addresses of web proxies. The system is based on an internet standard called Web Proxy Auto Discovery (WPAD). WPAD is in turn based on another standard called Proxy Auto Configuration (PAC). Both the Frontier and CVMFS clients support this standard. The input into the WLCG system comes from squids registered in the ATLAS Grid Information System (AGIS) and CMS SITECONF files, cross-checked with squids registered by sites in the Grid Configuration Database (GOCDB) and the OSG Information Management (OIM) system, and combined with some exceptions manually configured by people from ATLAS and CMS who operate WLCG Squid monitoring. WPAD servers at CERN respond to http requests from grid nodes all over the world with a PAC file that lists available web proxies, based on IP addresses matched from a database that contains the IP address ranges registered to organizations. Large grid sites are encouraged to supply their own WPAD web servers for more flexibility, to avoid being affected by short term long distance network outages, and to offload the WLCG WPAD servers at CERN. The CERN WPAD servers additionally support requests from jobs running at non-grid sites (particularly for LHC@Home) which it directs to the nearest publicly accessible web proxy servers. Furthermore, the responses to those requests are geographically ordered based on a separate database that maps IP addresses to longitude and latitude.« less
42 CFR 405.1012 - When CMS or its contractors may be a party to a hearing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false When CMS or its contractors may be a party to a... Hearings § 405.1012 When CMS or its contractors may be a party to a hearing. (a) CMS and/or one or more of... unrepresented beneficiary. (b) CMS and/or the contractor(s) advises the ALJ, appellant, and all other parties...
Multibody model reduction by component mode synthesis and component cost analysis
NASA Technical Reports Server (NTRS)
Spanos, J. T.; Mingori, D. L.
1990-01-01
The classical assumed-modes method is widely used in modeling the dynamics of flexible multibody systems. According to the method, the elastic deformation of each component in the system is expanded in a series of spatial and temporal functions known as modes and modal coordinates, respectively. This paper focuses on the selection of component modes used in the assumed-modes expansion. A two-stage component modal reduction method is proposed combining Component Mode Synthesis (CMS) with Component Cost Analysis (CCA). First, each component model is truncated such that the contribution of the high frequency subsystem to the static response is preserved. Second, a new CMS procedure is employed to assemble the system model and CCA is used to further truncate component modes in accordance with their contribution to a quadratic cost function of the system output. The proposed method is demonstrated with a simple example of a flexible two-body system.
Web Based Monitoring in the CMS Experiment at CERN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Badgett, William; Borrello, Laura; Chakaberia, Irakli
2014-09-03
The Compact Muon Solenoid (CMS) is a large and complex general purpose experiment at the CERN Large Hadron Collider (LHC), built and maintained by many collaborators from around the world. Efficient operation of the detector requires widespread and timely access to a broad range of monitoring and status information. To this end the Web Based Monitoring (WBM) system was developed to present data to users located anywhere from many underlying heterogeneous sources, from real time messaging systems to relational databases. This system provides the power to combine and correlate data in both graphical and tabular formats of interest to themore » experimenters, including data such as beam conditions, luminosity, trigger rates, detector conditions, and many others, allowing for flexibility on the user side. This paper describes the WBM system architecture and describes how the system was used during the first major data taking run of the LHC.« less
Performance of the CMS Event Builder
NASA Astrophysics Data System (ADS)
Andre, J.-M.; Behrens, U.; Branson, J.; Brummer, P.; Chaze, O.; Cittolin, S.; Contescu, C.; Craigs, B. G.; Darlea, G.-L.; Deldicque, C.; Demiragli, Z.; Dobson, M.; Doualot, N.; Erhan, S.; Fulcher, J. F.; Gigi, D.; Gładki, M.; Glege, F.; Gomez-Ceballos, G.; Hegeman, J.; Holzner, A.; Janulis, M.; Jimenez-Estupiñán, R.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; Morovic, S.; O'Dell, V.; Orsini, L.; Paus, C.; Petrova, P.; Pieri, M.; Racz, A.; Reis, T.; Sakulin, H.; Schwick, C.; Simelevicius, D.; Zejdl, P.
2017-10-01
The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider assembles events at a rate of 100 kHz, transporting event data at an aggregate throughput of {\\mathscr{O}}(100 {{GB}}/{{s}}) to the high-level trigger farm. The DAQ architecture is based on state-of-the-art network technologies for the event building. For the data concentration, 10/40 Gbit/s Ethernet technologies are used together with a reduced TCP/IP protocol implemented in FPGA for a reliable transport between custom electronics and commercial computing hardware. A 56 Gbit/s Infiniband FDR Clos network has been chosen for the event builder. This paper presents the implementation and performance of the event-building system.
42 CFR 414.68 - Imaging accreditation.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Computed tomography. (iii) Nuclear medicine. (iv) Positron emission tomography. CMS-approved accreditation... if CMS takes an adverse action based on accreditation findings. (vi) Notify CMS, in writing... organization must permit its surveyors to serve as witnesses if CMS takes an adverse action based on...
42 CFR 414.68 - Imaging accreditation.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Computed tomography. (iii) Nuclear medicine. (iv) Positron emission tomography. CMS-approved accreditation... if CMS takes an adverse action based on accreditation findings. (vi) Notify CMS, in writing... organization must permit its surveyors to serve as witnesses if CMS takes an adverse action based on...
42 CFR 414.68 - Imaging accreditation.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Computed tomography. (iii) Nuclear medicine. (iv) Positron emission tomography. CMS-approved accreditation... if CMS takes an adverse action based on accreditation findings. (vi) Notify CMS, in writing... organization must permit its surveyors to serve as witnesses if CMS takes an adverse action based on...
Production of muons from heavy-flavour hadron decays in p–Pb collisions at s NN = 5.02 TeV
Acharya, S.; Adamová, D.; Aggarwal, M. M.; ...
2017-03-28
The production of muons from heavy-flavour hadron decays in p–Pb collisions at √ sNN = 5.02 TeV was studied for 2< p T <16 GeV/c with the ALICE detector at the CERN LHC. The measurement was performed at forward (p-going direction) and backward (Pb-going direction) rapidity, in the ranges of rapidity in the centre-of-mass system (cms) 2.03 cms <3.53 and –4.46cms <–2.96, respectively. The production cross sections and nuclear modification factors are presented as a function of transverse momentum (p T). At forward rapidity, the nuclear modification factor is compatible with unity while at backward rapidity, in the interval 2.5more » < p T < 3.5 GeV/c, it is above unity by more than 2σ. The ratio of the forward-to-backward production cross sections is also measured in the overlapping interval 2.96<|y cms| < 3.53 and is smaller than unity by 3.7σ in 2.5< p T <3.5 GeV/c. The data are described by model calculations including cold nuclear matter effects.« less
Garcia, Nahuel A; Moncayo-Arlandi, Javier; Sepulveda, Pilar; Diez-Juan, Antonio
2016-03-01
Cardiomyocytes (CMs) and endothelial cells (ECs) have an intimate anatomical relationship, which is essential for maintaining the metabolic requirements of the heart. Little is known about the mechanisms that regulate nutrient flow from ECs to associated CMs, especially in situations of acute stress when local active processes are required to regulate endothelial transport. We examined whether CM-derived exosomes can modulate glucose transport and metabolism in ECs. In conditions of glucose deprivation, CMs increase the synthesis and secretion of exosomes. These exosomes are loaded with functional glucose transporters and glycolytic enzymes, which are internalized by ECs, leading to increased glucose uptake, glycolytic activity, and pyruvate production in recipient cells. These findings establish CM-derived exosomes as key components of the cardio-endothelial communication system which, through intercellular protein complementation, would allow a rapid response from ECs to increase glucose transport and a putative uptake of metabolic fuels from blood to CMs. This CM-EC protein complementation process might have implications for metabolic regulation in health and disease. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Mandel, Yael; Weissman, Amir; Schick, Revital; Barad, Lili; Novak, Atara; Meiry, Gideon; Goldberg, Stanislav; Lorber, Avraham; Rosen, Michael R; Itskovitz-Eldor, Joseph; Binah, Ofer
2012-02-21
The sinoatrial node is the main impulse-generating tissue in the heart. Atrioventricular conduction block and arrhythmias caused by sinoatrial node dysfunction are clinically important and generally treated with electronic pacemakers. Although an excellent solution, electronic pacemakers incorporate limitations that have stimulated research on biological pacing. To assess the suitability of potential biological pacemakers, we tested the hypothesis that the spontaneous electric activity of human embryonic stem cell-derived cardiomyocytes (hESC-CMs) and induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) exhibit beat rate variability and power-law behavior comparable to those of human sinoatrial node. We recorded extracellular electrograms from hESC-CMs and iPSC-CMs under stable conditions for up to 15 days. The beat rate time series of the spontaneous activity were examined in terms of their power spectral density and additional methods derived from nonlinear dynamics. The major findings were that the mean beat rate of hESC-CMs and iPSC-CMs was stable throughout the 15-day follow-up period and was similar in both cell types, that hESC-CMs and iPSC-CMs exhibited intrinsic beat rate variability and fractal behavior, and that isoproterenol increased and carbamylcholine decreased the beating rate in both hESC-CMs and iPSC-CMs. This is the first study demonstrating that hESC-CMs and iPSC-CMs exhibit beat rate variability and power-law behavior as in humans, thus supporting the potential capability of these cell sources to serve as biological pacemakers. Our ability to generate sinoatrial-compatible spontaneous cardiomyocytes from the patient's own hair (via keratinocyte-derived iPSCs), thus eliminating the critical need for immunosuppression, renders these myocytes an attractive cell source as biological pacemakers.
Miki, Shigehito; Yamashita, Taro; Wang, Zhen; Terai, Hirotaka
2014-04-07
We present the characterization of two-dimensionally arranged 64-pixel NbTiN superconducting nanowire single-photon detector (SSPD) array for spatially resolved photon detection. NbTiN films deposited on thermally oxidized Si substrates enabled the high-yield production of high-quality SSPD pixels, and all 64 SSPD pixels showed uniform superconducting characteristics within the small range of 7.19-7.23 K of superconducting transition temperature and 15.8-17.8 μA of superconducting switching current. Furthermore, all of the pixels showed single-photon sensitivity, and 60 of the 64 pixels showed a pulse generation probability higher than 90% after photon absorption. As a result of light irradiation from the single-mode optical fiber at different distances between the fiber tip and the active area, the variations of system detection efficiency (SDE) in each pixel showed reasonable Gaussian distribution to represent the spatial distributions of photon flux intensity.
Cheng, Jie; Dong, Shuqi; Yi, Litao; Geng, Di; Liu, Qing
2018-06-01
Magnolol, the main constituent of Magnolia officinalis, has been shown to produce antidepressant-like effect in rodents. Growing evidence shows that neuroinflammation, oxidative stress and neuroendocrine contribute to the pathogenesis of major depression. Here, the aim of this present study was to determine whether magnolol affected these systems in mice exposed to chronic mild stress (CMS). The ameliorative effect of magnolol on depressive-like symptoms was investigated through behavioral tests, including the classical sucrose preference and forced swimming tests. The behavioral evaluation showed that magnolol reversed the depressive-like deficits both in sucrose preference test and forced swimming test. The elevation of prefrontal cortex pro-inflammatory cytokines such as interleukin-1β (IL-1β), interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) was decreased by magnolol. Consistently, the microglia activation by CMS was also alleviated by magnolol. In addition, the hyperactivity of the hypothalamic-pituitary-adrenal (HPA) axis induced by CMS was attenuated by magnolol. Moreover, the increased lipid peroxidation such as malonaldehyde (MDA) and decreased antioxidant defense enzymes including superoxide dismutase (SOD) and glutathione peroxidase (GSH-Px) induced by CMS were also reversed by magnolol. These findings suggest that administration of magnolol could alleviate depressive-like behaviors in CMS mice that are mediated by suppressing neuroinflammation and oxidative stress in the prefrontal cortex. Copyright © 2018 Elsevier B.V. All rights reserved.
Inhibition of TGFβ signaling increases direct conversion of fibroblasts to induced cardiomyocytes.
Ifkovits, Jamie L; Addis, Russell C; Epstein, Jonathan A; Gearhart, John D
2014-01-01
Recent studies have been successful at utilizing ectopic expression of transcription factors to generate induced cardiomyocytes (iCMs) from fibroblasts, albeit at a low frequency in vitro. This work investigates the influence of small molecules that have been previously reported to improve differentiation to cardiomyocytes as well as reprogramming to iPSCs in conjunction with ectopic expression of the transcription factors Hand2, Nkx2.5, Gata4, Mef2C, and Tbx5 on the conversion to functional iCMs. We utilized a reporter system in which the calcium indicator GCaMP is driven by the cardiac Troponin T promoter to quantify iCM yield. The TGFβ inhibitor, SB431542 (SB), was identified as a small molecule capable of increasing the conversion of both mouse embryonic fibroblasts and adult cardiac fibroblasts to iCMs up to ∼5 fold. Further characterization revealed that inhibition of TGFβ by SB early in the reprogramming process led to the greatest increase in conversion of fibroblasts to iCMs in a dose-responsive manner. Global transcriptional analysis at Day 3 post-induction of the transcription factors revealed an increased expression of genes associated with the development of cardiac muscle in the presence of SB compared to the vehicle control. Incorporation of SB in the reprogramming process increases the efficiency of iCM generation, one of the major goals necessary to enable the use of iCMs for discovery-based applications and for the clinic.
Inhibition of TGFβ Signaling Increases Direct Conversion of Fibroblasts to Induced Cardiomyocytes
Ifkovits, Jamie L.; Addis, Russell C.; Epstein, Jonathan A.; Gearhart, John D.
2014-01-01
Recent studies have been successful at utilizing ectopic expression of transcription factors to generate induced cardiomyocytes (iCMs) from fibroblasts, albeit at a low frequency in vitro. This work investigates the influence of small molecules that have been previously reported to improve differentiation to cardiomyocytes as well as reprogramming to iPSCs in conjunction with ectopic expression of the transcription factors Hand2, Nkx2.5, Gata4, Mef2C, and Tbx5 on the conversion to functional iCMs. We utilized a reporter system in which the calcium indicator GCaMP is driven by the cardiac Troponin T promoter to quantify iCM yield. The TGFβ inhibitor, SB431542 (SB), was identified as a small molecule capable of increasing the conversion of both mouse embryonic fibroblasts and adult cardiac fibroblasts to iCMs up to ∼5 fold. Further characterization revealed that inhibition of TGFβ by SB early in the reprogramming process led to the greatest increase in conversion of fibroblasts to iCMs in a dose-responsive manner. Global transcriptional analysis at Day 3 post-induction of the transcription factors revealed an increased expression of genes associated with the development of cardiac muscle in the presence of SB compared to the vehicle control. Incorporation of SB in the reprogramming process increases the efficiency of iCM generation, one of the major goals necessary to enable the use of iCMs for discovery-based applications and for the clinic. PMID:24586958
CMS changes in reimbursement for HAIs: setting a research agenda.
Stone, Patricia W; Glied, Sherry A; McNair, Peter D; Matthes, Nikolas; Cohen, Bevin; Landers, Timothy F; Larson, Elaine L
2010-05-01
The Centers for Medicare and Medicaid Services (CMS) promulgated regulations commencing October 1, 2008, which deny payment for selected conditions occurring during the hospital stay and are not present on admission. Three of the 10 hospital-acquired conditions covered by the new CMS policy involve healthcare-associated infections, which are a common, expensive, and often preventable cause of inpatient morbidity and mortality. To outline a research agenda on the impact of CMS's payment policy on the healthcare system and the prevention of healthcare-associated infections. An invitational day-long conference was convened in April 2009. Including the planning committee and speakers there were 41 conference participants who were national experts and senior researchers. Building upon a behavioral model and organizational theory and management research a conceptual framework was applied to organize the wide range of issues that arose. A broad array of research topics was identified. Thirty-two research agenda items were organized in the areas of incentives, environmental factors, organizational factors, clinical outcomes, staff outcomes, and financial outcomes. Methodological challenges are also discussed. This policy is a first significant step to move output-based inpatient funding to outcome-based funding, and this agenda is applicable to all hospital-acquired conditions. Studies beginning soon will have the best hope of capturing data for the years preceding the policy change, a key element in non-experimental research. The CMS payment policy offers an excellent opportunity to understand and influence the use of financial incentives for improving patient safety.