Sample records for cngs facility performance

  1. Regeneration of long-distance peripheral nerve defects after delayed reconstruction in healthy and diabetic rats is supported by immunomodulatory chitosan nerve guides.

    PubMed

    Stenberg, Lena; Stößel, Maria; Ronchi, Giulia; Geuna, Stefano; Yin, Yaobin; Mommert, Susanne; Mårtensson, Lisa; Metzen, Jennifer; Grothe, Claudia; Dahlin, Lars B; Haastert-Talini, Kirsten

    2017-07-18

    Delayed reconstruction of transection or laceration injuries of peripheral nerves is inflicted by a reduced regeneration capacity. Diabetic conditions, more frequently encountered in clinical practice, are known to further impair regeneration in peripheral nerves. Chitosan nerve guides (CNGs) have recently been introduced as a new generation of medical devices for immediate peripheral nerve reconstruction. Here, CNGs were used for 45 days delayed reconstruction of critical length 15 mm rat sciatic nerve defects in either healthy Wistar rats or diabetic Goto-Kakizaki rats; the latter resembling type 2 diabetes. In short and long-term investigations, we comprehensively analyzed the performance of one-chambered hollow CNGs (hCNGs) and two-chambered CNGs (CFeCNGs) in which a chitosan film has been longitudinally introduced. Additionally, we investigated in vitro the immunomodulatory effect provided by the chitosan film. Both types of nerve guides, i.e. hCNGs and CFeCNGs, enabled moderate morphological and functional nerve regeneration after reconstruction that was delayed for 45 days. These positive findings were detectable in generally healthy as well as in diabetic Goto-Kakizaki rats (for the latter only in short-term studies). The regenerative outcome did not reach the degree as recently demonstrated after immediate reconstruction using hCNGs and CFeCNGs. CFeCNG-treatment, however, enabled tissue regrowth in all animals (hCNGs: only in 80% of animals). CFeCNGs did further support with an increased vascularization of the regenerated tissue and an enhanced regrowth of motor axons. One mechanism by which the CFeCNGs potentially support successful regeneration is an immunomodulatory effect induced by the chitosan film itself. Our in vitro results suggest that the pro-regenerative effect of chitosan is related to the differentiation of chitosan-adherent monocytes into pro-healing M2 macrophages. No considerable differences appear for the delayed nerve regeneration process related to healthy and diabetic conditions. Currently available chitosan nerve grafts do not support delayed nerve regeneration to the same extent as they do after immediate nerve reconstruction. The immunomodulatory characteristics of the biomaterial may, however, be crucial for their regeneration supportive effects.

  2. Chitosan-film enhanced chitosan nerve guides for long-distance regeneration of peripheral nerves.

    PubMed

    Meyer, Cora; Stenberg, Lena; Gonzalez-Perez, Francisco; Wrobel, Sandra; Ronchi, Giulia; Udina, Esther; Suganuma, Seigo; Geuna, Stefano; Navarro, Xavier; Dahlin, Lars B; Grothe, Claudia; Haastert-Talini, Kirsten

    2016-01-01

    Biosynthetic nerve grafts are developed in order to complement or replace autologous nerve grafts for peripheral nerve reconstruction. Artificial nerve guides currently approved for clinical use are not widely applied in reconstructive surgery as they still have limitations especially when it comes to critical distance repair. Here we report a comprehensive analysis of fine-tuned chitosan nerve guides (CNGs) enhanced by introduction of a longitudinal chitosan film to reconstruct critical length 15 mm sciatic nerve defects in adult healthy Wistar or diabetic Goto-Kakizaki rats. Short and long term investigations demonstrated that the CNGs enhanced by the guiding structure of the introduced chitosan film significantly improved functional and morphological results of nerve regeneration in comparison to simple hollow CNGs. Importantly, this was detectable both in healthy and in diabetic rats (short term) and the regeneration outcome almost reached the outcome after autologous nerve grafting (long term). Hollow CNGs provide properties likely leading to a wider clinical acceptance than other artificial nerve guides and their performance can be increased by simple introduction of a chitosan film with the same advantageous properties. Therefore, the chitosan film enhanced CNGs represent a new generation medical device for peripheral nerve reconstruction. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Comparative Evaluation of Chitosan Nerve Guides with Regular or Increased Bendability for Acute and Delayed Peripheral Nerve Repair: A Comprehensive Comparison with Autologous Nerve Grafts and Muscle-in-Vein Grafts.

    PubMed

    Stößel, Maria; Wildhagen, Vivien M; Helmecke, Olaf; Metzen, Jennifer; Pfund, Charlotte B; Freier, Thomas; Haastert-Talini, Kirsten

    2018-05-08

    Reconstruction of joint-crossing digital nerves requires the application of nerve guides with a much higher flexibility than used for peripheral nerve repair along larger bones. Nevertheless, collapse-resistance should be preserved to avoid secondary damage to the regrowing nerve tissue. In recent years, we presented chitosan nerve guides (CNGs) to be highly supportive for the regeneration of critical gap length peripheral nerve defects in the rat. Now, we evidently increased the bendability of regular CNGs (regCNGs) by developing a wavy wall structure, that is, corrugated CNGs (corrCNGs). In a comprehensive in vivo study, we compared both types of CNGs with clinical gold standard autologous nerve grafts (ANGs) and muscle-in-vein grafts (MVGs) that have recently been highlighted in the literature as a suitable alternative to ANGs. We reconstructed rat sciatic nerves over a critical gap length of 15 mm either immediately upon transection or after a delay period of 45 days. Electrodiagnostic measurements were applied to monitor functional motor recovery at 60, 90, 120, and 150 (only delayed repair) days postreconstruction. Upon explanation, tube properties were analyzed. Furthermore, distal nerve ends were evaluated using histomorphometry, while connective tissue specimens were subjected to immunohistological stainings. After 120 days (acute repair) or 150 days (delayed repair), respectively, compression-stability of regCNGs was slightly increased while it remained stable in corrCNGs. In both substudies, regCNGs and corrCNGs supported functional recovery of distal plantar muscles in a similar way and to a greater extent when compared with MVGs, while ANGs demonstrated the best support of regeneration. Anat Rec, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  4. Colloidal chitin nanogels: A plethora of applications under one shell.

    PubMed

    Vishnu Priya, M; Sabitha, M; Jayakumar, R

    2016-01-20

    Chitin nanogels (CNGs) are a relatively new class of natural polymeric nanomaterials which have a large potential in the field of drug delivery and nanotherapeutics. These nanogels being very biocompatible are non-toxic when internalized by cells. In this review various properties, preparation techniques and applications of CNGs have been described. CNGs because of their nano-size possess certain unique properties which enable them to be used in a number of biomedical applications. CNGs are prepared by simple regeneration technique without using any cross-linkers. Various polymers, drugs and fluorescent dyes can be blended or incorporated or labelled with the chitin hydrogel network. Drugs and molecules encapsulated within CNGs can be used for targeted delivery, in vivo monitoring or even for therapeutic purposes. Here various applications of CNGs in the field of drug delivery, imaging, sensing and therapeutics have been discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Molecular Diagnosis of Putative Stargardt Disease by Capture Next Generation Sequencing

    PubMed Central

    Shi, Wei; Huang, Ping; Min, Qingjie; Li, Minghan; Yu, Xinping; Wu, Yaming; Zhao, Guangyu; Tong, Yi; Jin, Zi-Bing; Qu, Jia; Gu, Feng

    2014-01-01

    Stargardt Disease (STGD) is the commonest genetic form of juvenile or early adult onset macular degeneration, which is a genetically heterogeneous disease. Molecular diagnosis of STGD remains a challenge in a significant proportion of cases. To address this, seven patients from five putative STGD families were recruited. We performed capture next generation sequencing (CNGS) of the probands and searched for potentially disease-causing genetic variants in previously identified retinal or macular dystrophy genes. Seven disease-causing mutations in ABCA4 and two in PROM1 were identified by CNGS, which provides a confident genetic diagnosis in these five families. We also provided a genetic basis to explain the differences among putative STGD due to various mutations in different genes. Meanwhile, we show for the first time that compound heterozygous mutations in PROM1 gene could cause cone-rod dystrophy. Our findings support the enormous potential of CNGS in putative STGD molecular diagnosis. PMID:24763286

  6. Status of the OPERA experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russo, A.

    2011-11-23

    The OPERA experiment in the underground Gran Sasso Laboratory (LNGS) has been designed to perform the first detection of neutrino oscillations in direct appearance mode in the muon to tau neutrino channel. The detector is hybrid, being made of an emulsion/lead target and of electronic detectors. It is placed in the CNGS neutrino beam 733 km away from the neutrino source. Runs with CNGS neutrinos were successfully carried out from 2008 and the following years. The analysis of a sample of events corresponding to 1.89x10{sup 19} p.o.t. in the CERN CNGS {nu}{sub {mu}} beam yielded the observation of a firstmore » candidate {nu}{sub {tau}} CC interaction. The topology and kinematics of this candidate event is described in detail. The background sources are explained and the significance of the observation of the first {nu}{sub {tau}} event candidate is assessed.« less

  7. A taxonomy of medical uncertainties in clinical genome sequencing.

    PubMed

    Han, Paul K J; Umstead, Kendall L; Bernhardt, Barbara A; Green, Robert C; Joffe, Steven; Koenig, Barbara; Krantz, Ian; Waterston, Leo B; Biesecker, Leslie G; Biesecker, Barbara B

    2017-08-01

    Clinical next-generation sequencing (CNGS) is introducing new opportunities and challenges into the practice of medicine. Simultaneously, these technologies are generating uncertainties of an unprecedented scale that laboratories, clinicians, and patients are required to address and manage. We describe in this report the conceptual design of a new taxonomy of uncertainties around the use of CNGS in health care. Interviews to delineate the dimensions of uncertainty in CNGS were conducted with genomics experts and themes were extracted in order to expand on a previously published three-dimensional taxonomy of medical uncertainty. In parallel, we developed an interactive website to disseminate the CNGS taxonomy to researchers and engage them in its continued refinement. The proposed taxonomy divides uncertainty along three axes-source, issue, and locus-and further discriminates the uncertainties into five layers with multiple domains. Using a hypothetical clinical example, we illustrate how the taxonomy can be applied to findings from CNGS and used to guide stakeholders through interpretation and implementation of variant results. The utility of the proposed taxonomy lies in promoting consistency in describing dimensions of uncertainty in publications and presentations, to facilitate research design and management of the uncertainties inherent in the implementation of CNGS.Genet Med advance online publication 19 January 2017.

  8. A Taxonomy of Medical Uncertainties in Clinical Genome Sequencing

    PubMed Central

    Han, Paul K. J.; Umstead, Kendall L.; Bernhardt, Barbara A.; Green, Robert C.; Joffe, Steven; Koenig, Barbara; Krantz, Ian; Waterston, Leo B.; Biesecker, Leslie G.; Biesecker, Barbara B.

    2017-01-01

    Purpose Clinical next generation sequencing (CNGS) is introducing new opportunities and challenges into the practice of medicine. Simultaneously, these technologies are generating uncertainties of unprecedented scale that laboratories, clinicians, and patients are required to address and manage. We describe in this report the conceptual design of a new taxonomy of uncertainties around the use of CNGS in health care. Methods Interviews to delineate the dimensions of uncertainty in CNGS were conducted with genomics experts, and themes were extracted in order to expand upon a previously published three-dimensional taxonomy of medical uncertainty. In parallel we developed an interactive website to disseminate the CNGS taxonomy to researchers and engage them in its continued refinement. Results The proposed taxonomy divides uncertainty along three axes: source, issue, and locus, and further discriminates the uncertainties into five layers with multiple domains. Using a hypothetical clinical example, we illustrate how the taxonomy can be applied to findings from CNGS and used to guide stakeholders through interpretation and implementation of variant results. Conclusion The utility of the proposed taxonomy lies in promoting consistency in describing dimensions of uncertainty in publications and presentations, to facilitate research design and management of the uncertainties inherent in the implementation of CNGS. PMID:28102863

  9. Search for νμ → νe oscillations with the OPERA experiment in the CNGS beam

    NASA Astrophysics Data System (ADS)

    Tenti, M.; OPERA Collaboration

    2016-04-01

    The OPERA hybrid detector, designed to prove neutrino oscillations in the νμ →ντ channel, was exposed to the CNGS νμ beam at a distance of 730 km from the neutrino source. Profiting of the tracking capabilities of its Emulsion Cloud Chamber system, OPERA can perform also a search for νμ →νe oscillations. Current results are compatible with the non-oscillation hypothesis in the three flavour mixing model. The same data allow to constrain the non-standard oscillation parameters θnew and Δmnew2 indicated by the LSND and MiniBooNE experiments.

  10. Acitretin and aloe-emodin loaded chitin nanogel for the treatment of psoriasis.

    PubMed

    Divya, G; Panonnummal, Rajitha; Gupta, Swati; Jayakumar, R; Sabitha, M

    2016-10-01

    The present study focuses on the development of an effective topical nanogel formulation of two anti-psoriatic drugs; Acitretin (Act) and Aloe-emodin (AE) using natural polymer chitin. Simple regeneration chemistry was used to prepare Chitin Nanogel Systems (CNGs). The developed control chitin (CNGs) nanogels, acitretin loaded chitin nanogels (ActCNGs) and aloe-emodin loaded chitin nanogels (AECNGs) were characterized by DLS, SEM, FTIR, XRD and TG-DTA. The systems were found to be spherical in shape with a size range of 98±10, 138±8 and 238±6nm having zeta potential values of +28±3, +27±3 and +25±6mV for CNGs, ActCNGs and AECNGs respectively. The in vitro haemolysis assay revealed that all the nanogel systems are blood compatible. The systems exhibited higher swelling and release at acidic pH. The ex vivo skin permeation studies using porcine skin confirmed the higher deposition of the systems at epidermal and dermal layers, which was confirmed further by fluorescent imaging. The in vivo anti-psoriatic activity study using Perry's mouse tail model and skin safety studies confirmed the potential benefit of the system for topical delivery of acitretin and aloe-emodin in psoriasis. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Latest results from the OPERA experiment

    NASA Astrophysics Data System (ADS)

    Duchesneau, D.; OPERA Collaboration

    2017-09-01

    The OPERA experiment has been designed to perform the first detection of neutrino oscillations in the ν μ → ν τ channel in direct appearance mode, through the event by event detection of the τ lepton produced in ν τ charged current interactions. OPERA is a hybrid detector, made of emulsion/lead target elements and of electronic detectors, placed in the CNGS muon neutrino beam from CERN to Gran Sasso, 730 km away from the source. Neutrino interactions from the CNGS neutrino runs were recorded from 2008 until the end of 2012. We report on the data sample analysed so far and give the latest OPERA results on ν μ → ν τ oscillation, ν e analysis and the first ν μ disappearance study.

  12. Results from the OPERA experiment

    NASA Astrophysics Data System (ADS)

    Crescenzo, A. Di

    2017-12-01

    The OPERA neutrino experiment was designed to perform a unique vτ appearance measurement in the vμ CNGS beam to confirm the oscillation mechanism in the atmospheric sector vμ → vτ. The detection of vτ leptons produced in vτ CC interactions and of their decays is accomplished exploiting the high spatial resolution of nuclear emulsions. Five vτ candidate events have been detected in the full data sample from 2008-2012 CNGS runs, with an expected background of 0.25 events. The background only hypothesis is rejected with a significance larger than 5 σ. The analysis of the tau neutrino sample in the framework of the 3+1 neutrino model is also presented. Furthermore OPERA good capabilities in detecting electron neutrino interactions allow setting limits on the vμ → ve oscillation channel.

  13. A recurrent deletion mutation in OPA1 causes autosomal dominant optic atrophy in a Chinese family

    NASA Astrophysics Data System (ADS)

    Zhang, Liping; Shi, Wei; Song, Liming; Zhang, Xiao; Cheng, Lulu; Wang, Yanfang; Ge, Xianglian; Li, Wei; Zhang, Wei; Min, Qingjie; Jin, Zi-Bing; Qu, Jia; Gu, Feng

    2014-11-01

    Autosomal dominant optic atrophy (ADOA) is the most frequent form of hereditary optic neuropathy and occurs due to the degeneration of the retinal ganglion cells. To identify the genetic defect in a family with putative ADOA, we performed capture next generation sequencing (CNGS) to screen known retinal disease genes. However, six exons failed to be sequenced by CNGS in optic atrophy 1 gene (OPA1). Sequencing of those exons identified a 4 bp deletion mutation (c.2983-1_2985del) in OPA1. Furthermore, we sequenced the transcripts of OPA1 from the patient skin fibroblasts and found there is six-nucleotide deletion (c.2984-c.2989, AGAAAG). Quantitative-PCR and Western blotting showed that OPA1 mRNA and its protein expression have no obvious difference between patient skin fibroblast and control. The analysis of protein structure by molecular modeling suggests that the mutation may change the structure of OPA1 by formation of an alpha helix protruding into an existing pocket. Taken together, we identified an OPA1 mutation in a family with ADOA by filling the missing CNGS data. We also showed that this mutation affects the structural intactness of OPA1. It provides molecular insights for clinical genetic diagnosis and treatment of optic atrophy.

  14. A recurrent deletion mutation in OPA1 causes autosomal dominant optic atrophy in a Chinese family.

    PubMed

    Zhang, Liping; Shi, Wei; Song, Liming; Zhang, Xiao; Cheng, Lulu; Wang, Yanfang; Ge, Xianglian; Li, Wei; Zhang, Wei; Min, Qingjie; Jin, Zi-Bing; Qu, Jia; Gu, Feng

    2014-11-06

    Autosomal dominant optic atrophy (ADOA) is the most frequent form of hereditary optic neuropathy and occurs due to the degeneration of the retinal ganglion cells. To identify the genetic defect in a family with putative ADOA, we performed capture next generation sequencing (CNGS) to screen known retinal disease genes. However, six exons failed to be sequenced by CNGS in optic atrophy 1 gene (OPA1). Sequencing of those exons identified a 4 bp deletion mutation (c.2983-1_2985del) in OPA1. Furthermore, we sequenced the transcripts of OPA1 from the patient skin fibroblasts and found there is six-nucleotide deletion (c.2984-c.2989, AGAAAG). Quantitative-PCR and Western blotting showed that OPA1 mRNA and its protein expression have no obvious difference between patient skin fibroblast and control. The analysis of protein structure by molecular modeling suggests that the mutation may change the structure of OPA1 by formation of an alpha helix protruding into an existing pocket. Taken together, we identified an OPA1 mutation in a family with ADOA by filling the missing CNGS data. We also showed that this mutation affects the structural intactness of OPA1. It provides molecular insights for clinical genetic diagnosis and treatment of optic atrophy.

  15. Spectral and laser properties of Er3+/Yb3+/Ce3+ tri-doped Ca3NbGa3Si2O14 crystal at 1.55 µm

    NASA Astrophysics Data System (ADS)

    Gong, Guoliang; Chen, Yujin; Lin, Yanfu; Huang, Jianhua; Gong, Xinghong; Luo, Zundu; Huang, Yidong

    2018-04-01

    An Er3+/Yb3+/Ce3+ tri-doped Ca3NbGa3Si2O14 (CNGS) crystal was grown by the Czochralski method. Spectral properties of the crystal, including the polarized absorption and fluorescence spectra, the fluorescence decay, as well as the energy transfer efficiency from Yb3+ to Er3+ were investigated in detail. End-pumped by a 976 nm diode laser, a 1556 nm continuous-wave laser with a maximum output power of 202 mW and a slope efficiency of 11.4% was achieved in the Er,Yb,Ce:CNGS crystal. The results indicate the Er,Yb,Ce:CNGS crystal is a promising 1.55 µm laser gain medium.

  16. Petit-exposure at neutrino beamline (PEANUT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Niwa, K.; /Nagoya U.

    2005-08-01

    The advantages of using nuclear emulsion as a particle detector are well known. The high resolution of emulsion has made it a medium of choice for a number of applications where the required spatial and angular resolution are paramount and its limitations due to the lack of timing information are less important. Emulsions are commonly used as cosmic ray detectors and have found applications in high energy experiments for detecting short lived particles such as charm, beauty and tau. The addition of electronic detectors to emulsion experiments solved the problem of the lack of timing information in the emulsion, butmore » it was the development of automatic scanning machines that revolutionized the use of these hybrid detectors, making them capable of performing even in high rate environments. Most recently, The DONuT experiment (FNAL-E872), used a hybrid emulsion spectrometer to make the first direct observation of tau neutrino interactions [1]. The CNGS facility is being constructed to deliver a {nu}{sub {mu}} beam from the CERN SPS to the Gran Sasso Laboratory. Since it is believed that {nu}{sub {mu}} {leftrightarrow} {nu}{sub {tau}} oscillations explain the observed atmospheric {nu}{sub {mu}} deficit, the CNGS beam, coupled with a detector capable of observing {tau} appearance is an important experiment in the context of the world wide effort to determine the neutrino mass mixing matrix. The OPERA detector has been optimized to detect a significant sample of {nu}{sub {tau}} interactions by the subsequent observation of {tau} production and decay [2]. The OPERA target is a massive emulsion detector made in a sandwich structure of lead plates and layers of nuclear emulsion. For historical reasons this arrangement has been called an Emulsion Cloud Chamber or ECC. The ECC concept, which has many advantages over the use of bulk emulsion, has been used in the DONuT experiment. The ECC detector is capable of measuring all of the tracks, not due to nuclear fragments, coming from the primary neutrino interaction vertex, with their three dimensional slopes and momenta. It is also capable of electron identification with good e/{gamma} separation, due to its very fine segmentation. The OPERA ECC target modules are constructed as bricks of dimensions 12.5 x 10.0 x 7.5 cm{sup 3} in horizontal, vertical and along the beam axis. Each brick consists of series of 56 (1 mm thick) plates of passive material (lead or iron) alternated with emulsion films (43 {micro}m emulsion layer on both sides of a transparent 200 {micro}m thick plastic film). In preparation for OPERA we would like to expose the OPERA target modules to a beam of neutrinos. This will allow us to test many of our analysis procedures and techniques as well as to validate the simulation of neutrino interactions, both for the production of forward and backward particles. Although the HE (high energy) beam of NuMI would be a better match to the CNGS energy, data acquired with NuMI LE (low energy) beam would serve the same purpose, albeit more challenging. Given the high interaction rate from the NuMI beam, the test detector target mass can be kept low and additional detectors can easily be built around a small target. These measurements are not possible in the CNGS beam, since it has no short baseline hall.« less

  17. The Detection Of Neutrino Interactions In The OPERA Experiment: An Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patrizii, Laura

    2009-12-17

    OPERA is a long baseline neutrino oscillation experiment built to provide the final and unambiguous proof of the neutrino oscillation hypothesis in the atmospheric sector by observing {nu}{sub {tau}} emerging from the CNGS {nu}{sub {mu}} beam. The detector is a hybrid apparatus installed in the Hall C of the underground Gran Sasso National Laboratory in Italy. Runs with CNGS neutrinos were successfully carried out in 2007 and 2008. In this paper the detector and the analysis strategy are briefly described and the status of the analysis of the 2008 run events is discussed.

  18. Results from the OPERA experiment at the CNGS beam

    NASA Astrophysics Data System (ADS)

    Mauri, N.

    2017-12-01

    The OPERA experiment at the Gran Sasso underground laboratory was designed to study vμ → vτ oscillations in appearance mode in the CNGS neutrino beam. Five vτ candidate events have been observed, allowing to assess the discovery of vμ → vτ transitions in the atmospheric sector with a significance of 5.1σ. In this paper the vτ data analysis will be discussed, with emphasis on the background constraints obtained using dedicated data-driven control samples. Results on the search for vμ → vτ oscillations, on the search for sterile neutrino mixing and on the atmospheric muon charge ratio will also be presented.

  19. Results from the OPERA experiment in the CNGS beam

    NASA Astrophysics Data System (ADS)

    Di Marco, N.; OPERA Collaboration

    2016-05-01

    The OPERA experiment at the Gran Sasso underground laboratory was designed to study ν μ → ν τ oscillations in appearance mode in the CNGS neutrino beam. In this paper we report the detection of the 5 th ν τ candidate event found in the analysis of an enlarged data sample. Given the number of analysed events and the low background, ν μ → ν τ oscillations have been established with a significance of 5.1σ. The analysis of the present electron neutrino sample in the framework of the 3 + 1 sterile model is also presented. Finally the analysis of the muon charge ratio in the cosmic ray sample is discussed.

  20. Recent results from the OPERA experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meregaglia, Anselmo

    2009-04-17

    OPERA is a long-baseline neutrino oscillation experiment whose main goal is to detect for the first time neutrino oscillations in an appearance mode. Using an almost pure v{sub {mu}} beam we search for a v{sub {mu}}{r_reversible}v{sub {tau}}, transition detecting in a direct way the {tau} lepton. The detector is located on the high-energy, long-baseline CERN to LNGS beam (CNGS) at a baseline of 730 km. The apparatus consists of a target made of lead/emulsion-films bricks and of electronic detectors which are used to tag the neutrino interaction. Experiment description and results from the short but fruitful 2007 CNGS run aremore » reported in details.« less

  1. OPERA experiment and its releted emulsion techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ariga, Akitaka

    2008-02-21

    The OPERA experiment is designed to clarify neutrino oscillation by detecting appearance of {nu}{sub {tau}} in pure {nu}{sub {mu}} beam through a long baseline method (CNGS beam from cern to the Gran Sasso laboratory). The key technique is the use of emulsion films and their scanning. We developed a new high speed scanning system with speed of 50 cm{sup 2}/h and it was successfully demonstrated in 2006 CNGS commissioning. The new scanning system is not only meant for the OPERA experiment, but it has large potential of applications. For example, measurement of {nu}{sub e} with strong separation power against {pi}{supmore » 0}. Or a compact emulsion spectrometer for future neutrino experiments.« less

  2. Controlled curcumin release via conjugation into PBAE nanogels enhances mitochondrial protection against oxidative stress.

    PubMed

    Gupta, Prachi; Jordan, Carolyn T; Mitov, Mihail I; Butterfield, D Allan; Hilt, J Zach; Dziubla, Thomas D

    2016-09-25

    Mitochondria are considered to be the "power plants" of the cell, but can also initiate and execute cell death, stimulated by oxidative stress (OS). OS induced mitochondrial dysfunction is characterized by a loss in oxygen consumption and reduced ATP production. Curcumin, as a potential therapeutic, has been explored as a candidate for mitochondrial OS suppression, but rapid metabolism and aqueous insolubility has prevented it from being effective. Further, efficient delivery of curcumin via the incorporation into nanocarriers has again been limited due to low drug loading capacities and/or significant burst release, resulting in acute cytotoxicity. Hence, to increase the therapeutic potential and reduce the toxic effects of curcumin, curcumin conjugated poly(β-amino ester) nanogels (CNGs) were synthesized using Michael addition chemistry. This approach provided easy control over the nanogel size, with CNGs showing a uniform release of active curcumin over 48h with no burst release. This controlled release system significantly increased the safety limit for curcumin, with a ten fold increase in the cytotoxic threshold, as compared to free curcumin. Further, real-time mitochondrial response analysis with the Seahorse XF96 showed effective and prolonged suppression of H2O2 induced mitochondrial oxidative stress upon pre-treating endothelial cells with CNGs and this potential of nanogels was studied at different pre-treatment times prior to H2O2 exposure. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. OPERA neutrino oscillation search: Status and perspectives

    NASA Astrophysics Data System (ADS)

    Gornushkin, Yu.

    2016-07-01

    OPERA is a long-baseline neutrino experiment at the Gran Sasso laboratory (LNGS) designed to search for ν_{{μ}}^{} → ν_{{τ}}^{} oscillations in a direct appearance mode on an event by event basis. OPERA took data in 2008-2012 with the CNGS neutrino beam from CERN. The data analysis is ongoing, with the goal of establishing ν_{{τ}}^{} appearance with a high significance. Complementary studies of the ν_{{μ}}^{} → ν_{{e}}^{} oscillations and atmospheric muons fluxes were performed as well. Current results of the experiment are presented and perspectives discussed.

  4. Bio-responsive chitin-poly(L-lactic acid) composite nanogels for liver cancer.

    PubMed

    Arunraj, T R; Sanoj Rejinold, N; Ashwin Kumar, N; Jayakumar, R

    2014-01-01

    Hepatic carcinoma (HCC) is one of the most common cancer and its treatment has been considered a therapeutic challenge. Doxorubicin (Dox) is one of the most important chemotherapeutic agents used in the treatment for liver cancer. However, the efficacy of Dox therapy is restricted by the dose-dependent toxic side effects. To overcome the cardiotoxicity of Dox as well as the current problems of conventional modality treatment of HCC, we developed a locally injectable, biodegradable, and pH sensitive composite nanogels for site specific delivery. Both control and Dox loaded composite nanogel systems were analyzed by DLS, SEM, FTIR and TG/DTA. The size ranges of the control composite nanogels and their drug loaded counterparts were found to be 90±20 and 270±20 nm, respectively. The control chitin-PLA CNGs and Dox-chitin-PLA CNGs showed higher swelling and degradation in acidic pH. Drug entrapment efficiency and in vitro drug release studies were carried out and showed a higher drug release at acidic pH compared to neutral pH. Cellular internalization of the nanogel systems was confirmed by fluorescent microscopy. The cytotoxicity of the composite nanogels was analyzed toward HepG2 (human liver cancer) cell lines. Furthermore, the results of in vitro hemolytic assay and coagulation assay substantiate the blood compatibility of the system. Overall Dox-chitin-PLA CNGs system could be a promising anticancer drug delivery system for liver cancer therapy. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Large-Angle Scattering of Multi-GeV Muons on Thin Lead Targets

    NASA Astrophysics Data System (ADS)

    Longhin, A.; Paoloni, A.; Pupilli, F.

    2015-10-01

    The probability of large-angle scattering for multi-GeV muons in lead targets with a thickness of O(10 - 1) radiation lengths is studied. The new estimates presented here are based both on simulation programs (GEANT4 libraries) and theoretical calculations. In order to validate the results provided by simulation, a comparison is drawn with experimental data from the literature. This study is particularly relevant when applied to muons originating from νμ CC interactions of CNGS beam neutrinos. In that circumstance the process under study represents the dominant background for the νμ → ντ search in the τ→ μ channel for the OPERA experiment at LNGS. Finally we also investigate, in the CNGS context, possible contributions from the muon photo-nuclear process which might in principle also produce a large-angle muon scattering signature in the detector.

  6. Final Results of the OPERA Experiment on ντ Appearance in the CNGS Neutrino Beam

    NASA Astrophysics Data System (ADS)

    Agafonova, N.; Alexandrov, A.; Anokhina, A.; Aoki, S.; Ariga, A.; Ariga, T.; Bertolin, A.; Bozza, C.; Brugnera, R.; Buonaura, A.; Buontempo, S.; Chernyavskiy, M.; Chukanov, A.; Consiglio, L.; D'Ambrosio, N.; de Lellis, G.; de Serio, M.; Del Amo Sanchez, P.; di Crescenzo, A.; di Ferdinando, D.; di Marco, N.; Dmitrievsky, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Dzhatdoev, T.; Ebert, J.; Ereditato, A.; Favier, J.; Fini, R. A.; Fornari, F.; Fukuda, T.; Galati, G.; Garfagnini, A.; Gentile, V.; Goldberg, J.; Gorbunov, S.; Gornushkin, Y.; Grella, G.; Guler, A. M.; Gustavino, C.; Hagner, C.; Hara, T.; Hayakawa, T.; Hollnagel, A.; Ishiguro, K.; Iuliano, A.; Jakovcic, K.; Jollet, C.; Kamiscioglu, C.; Kamiscioglu, M.; Kim, S. H.; Kitagawa, N.; Klicek, B.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Laudisio, F.; Lauria, A.; Ljubicic, A.; Longhin, A.; Loverre, P.; Malenica, M.; Malgin, A.; Mandrioli, G.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meregaglia, A.; Mikado, S.; Miyanishi, M.; Mizutani, F.; Monacelli, P.; Montesi, M. C.; Morishima, K.; Muciaccia, M. T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Niwa, K.; Ogawa, S.; Okateva, N.; Olchevsky, A.; Ozaki, K.; Paoloni, A.; Paparella, L.; Park, B. D.; Pasqualini, L.; Pastore, A.; Patrizii, L.; Pessard, H.; Pistillo, C.; Podgrudkov, D.; Polukhina, N.; Pozzato, M.; Pupilli, F.; Roda, M.; Roganova, T.; Rokujo, H.; Rosa, G.; Ryazhskaya, O.; Sadovsky, A.; Sato, O.; Schembri, A.; Shakiryanova, I.; Shchedrina, T.; Shibayama, E.; Shibuya, H.; Shiraishi, T.; Simone, S.; Sirignano, C.; Sirri, G.; Sotnikov, A.; Spinetti, M.; Stanco, L.; Starkov, N.; Stellacci, S. M.; Stipcevic, M.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Tufanli, S.; Ustyuzhanin, A.; Vasina, S.; Vilain, P.; Voevodina, E.; Votano, L.; Vuilleumier, J. L.; Wilquet, G.; Wonsak, B.; Yoon, C. S.; Opera Collaboration

    2018-05-01

    The OPERA experiment was designed to study νμ→ντ oscillations in the appearance mode in the CERN to Gran Sasso Neutrino beam (CNGS). In this Letter, we report the final analysis of the full data sample collected between 2008 and 2012, corresponding to 17.97 ×1019 protons on target. Selection criteria looser than in previous analyses have produced ten ντ candidate events, thus reducing the statistical uncertainty in the measurement of the oscillation parameters and of ντ properties. A multivariate approach for event identification has been applied to the candidate events and the discovery of ντ appearance is confirmed with an improved significance level of 6.1 σ . |Δ m322| has been measured, in appearance mode, with an accuracy of 20%. The measurement of the ντ charged-current cross section, for the first time with a negligible contamination from ν¯τ, and the first direct evidence for the ντ lepton number are also reported.

  7. Track reconstruction in the emulsion-lead target of the OPERA experiment using the ESS microscope

    NASA Astrophysics Data System (ADS)

    Arrabito, L.; Bozza, C.; Buontempo, S.; Consiglio, L.; Cozzi, M.; D'Ambrosio, N.; DeLellis, G.; DeSerio, M.; Di Capua, F.; Di Ferdinando, D.; Di Marco, N.; Ereditato, A.; Esposito, L. S.; Fini, R. A.; Giacomelli, G.; Giorgini, M.; Grella, G.; Ieva, M.; Janicsko Csathy, J.; Juget, F.; Kreslo, I.; Laktineh, I.; Manai, K.; Mandrioli, G.; Marotta, A.; Migliozzi, P.; Monacelli, P.; Moser, U.; Muciaccia, M. T.; Pastore, A.; Patrizii, L.; Petukhov, Y.; Pistillo, C.; Pozzato, M.; Romano, G.; Rosa, G.; Russo, A.; Savvinov, N.; Schembri, A.; Scotto Lavina, L.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Strolin, P.; Tioukov, V.; Waelchli, T.

    2007-05-01

    The OPERA experiment, designed to conclusively prove the existence of νμ→ντ oscillations in the atmospheric sector, makes use of a massive lead-nuclear emulsion target to observe the appearance of ντ's in the CNGS νμ beam. The location and analysis of the neutrino interactions in quasi real-time required the development of fast computer-controlled microscopes able to reconstruct particle tracks with sub-micron precision and high efficiency at a speed of ~20 cm2/h. This paper describes the performance in particle track reconstruction of the European Scanning System, a novel automatic microscope for the measurement of emulsion films developed for OPERA.

  8. Short and Long Baseline Neutrino Experiments

    NASA Astrophysics Data System (ADS)

    Autiero, Dario

    2005-04-01

    These two lectures discuss the past and current neutrino oscillation experiments performed with man-made neutrino sources, like accelerators and nuclear reactors. The search for neutrino oscillations is a remarkable effort, which has been performed over three decades. It is therefore interesting to discuss the short and long baseline neutrino experiments in their historical context and to see how this line of research evolved up to the present generation of experiments, looking at what was learnt from past experiments and how this experience is used in the current ones. The first lecture focuses on the past generation of short baseline experiments (NOMAD and CHORUS) performed at CERN and ends with LSND and MINIBOONE. The second lecture discusses how after the CHOOZ and the atmospheric neutrino results the line of the long baseline experiments developed and presents in details the K2K and MINOS experiments and the CNGS program.

  9. Experimental search for the "LSND anomaly" with the ICARUS detector in the CNGS neutrino beam

    NASA Astrophysics Data System (ADS)

    Antonello, M.; Baibussinov, B.; Benetti, P.; Calligarich, E.; Canci, N.; Centro, S.; Cesana, A.; Cieślik, K.; Cline, D. B.; Cocco, A. G.; Dabrowska, A.; Dequal, D.; Dermenev, A.; Dolfini, R.; Farnese, C.; Fava, A.; Ferrari, A.; Fiorillo, G.; Gibin, D.; Gninenko, S.; Guglielmi, A.; Haranczyk, M.; Holeczek, J.; Ivashkin, A.; Kirsanov, M.; Kisiel, J.; Kochanek, I.; Lagoda, J.; Mania, S.; Menegolli, A.; Meng, G.; Montanari, C.; Otwinowski, S.; Piazzoli, A.; Picchi, P.; Pietropaolo, F.; Plonski, P.; Rappoldi, A.; Raselli, G. L.; Rossella, M.; Rubbia, C.; Sala, P. R.; Scantamburlo, E.; Scaramelli, A.; Segreto, E.; Sergiampietri, F.; Stefan, D.; Stepaniak, J.; Sulej, R.; Szarska, M.; Terrani, M.; Varanini, F.; Ventura, S.; Vignoli, C.; Wang, H. G.; Yang, X.; Zalewska, A.; Zaremba, K.

    2013-03-01

    We report an early result from the ICARUS experiment on the search for a ν μ → ν e signal due to the LSND anomaly. The search was performed with the ICARUS T600 detector located at the Gran Sasso Laboratory, receiving CNGS neutrinos from CERN at an average energy of about 20 GeV, after a flight path of ˜730 km. The LSND anomaly would manifest as an excess of ν e events, characterized by a fast energy oscillation averaging approximately to sin2(1.27Δ m2_{new}L/E_{ν})≈ 1/2 with probability P_{ν_{μ}→ νe} = 1/2 sin2(2θ_{new}). The present analysis is based on 1091 neutrino events, which are about 50 % of the ICARUS data collected in 2010-2011. Two clear ν e events have been found, compared with the expectation of 3.7±0.6 events from conventional sources. Within the range of our observations, this result is compatible with the absence of a LSND anomaly. At 90 % and 99 % confidence levels the limits of 3.4 and 7.3 events corresponding to oscillation probabilities < P_{ν_{μ}→ νe}rangle le 5.4 × 10^{-3} and < P_{ν_{μ}→ νe}rangle le 1.1 × 10^{-2} are set respectively. The result strongly limits the window of open options for the LSND anomaly to a narrow region around (Δ m 2,sin2(2 θ))new=(0.5 eV2,0.005), where there is an overall agreement (90 % CL) between the present ICARUS limit, the published limits of KARMEN and the published positive signals of LSND and MiniBooNE Collaborations.

  10. Chemical Composition and Emission Sources of the Fine Particulate Matters in a Southeast Asian Mega City (Dhaka, Bangladesh)

    NASA Astrophysics Data System (ADS)

    Salam, Abdus

    2016-04-01

    Air pollution has significant impact on human health, climate change, agriculture, visibility reduction, and also on the atmospheric chemistry. There are many studies already reported about the direct relation of the human mortality and morbidity with the increase of the atmospheric particulate matters. Especially, fine particulate matters can easily enter into the human respiratory system and causes many diseases. Particulate matters have the properties to absorb the solar radiation and impact on the climate. Dhaka, Bangladesh is a densely populated mega-city in the world. About 16 million inhabitants are living within an area of 360 square kilometers. Air quality situation has been degrading due to unplanned growth, increasing vehicles, severe traffic jams, brick kilns, industries, construction, and also transboundary air pollution. A rapidly growing number of vehicles has worsen the air quality in spite of major policy interventions, e.g., ban of two-stroke and three-wheeled vehicles, phase out of 20 years old vehicles, conversion to compressed natural gas (CNGs), etc. Introduction of CNGs to reduce air pollution was not the solution for fine particles at all, as evidence shows that CNGs and diesel engines are the major sources of fine particles. High concentration of the air pollutants in Dhaka city such as PM, carbonaceous species (black and organic carbon), CO, etc. has already been reported. PM2.5 mass, chemical composition (e.g., BC, OC, SO42-, NO3-, trace elements, etc.), aerosol Optical Depth (AOD) and emission sources of our recent measurements at the highly polluted south East Asian Mega city (Dhaka) Bangladesh will be presented in the conference. PM2.5 samples were collected on filters with Digital PM2.5 sampler (Switzerland) and Air photon, USA. BC was measured from filters (with thermal and optical method) and also real time with an Aethalometer AE42 (Magee Scitific., USA). Water soluble ions were determined from filters with ion chromatogram. AOD was continuously monitor with NASA AERONET sunphotometer. Carbon monoxide (CO) was measured continuously with Horiba CO monitor, Japan.

  11. Species selection under long-term experimental warming and drought explained by climatic distributions.

    PubMed

    Liu, Daijun; Peñuelas, Josep; Ogaya, Romà; Estiarte, Marc; Tielbörger, Katja; Slowik, Fabian; Yang, Xiaohong; Bilton, Mark C

    2018-03-01

    Global warming and reduced precipitation may trigger large-scale species losses and vegetation shifts in ecosystems around the world. However, currently lacking are practical ways to quantify the sensitivity of species and community composition to these often-confounded climatic forces. Here we conducted long-term (16 yr) nocturnal-warming (+0.6°C) and reduced precipitation (-20% soil moisture) experiments in a Mediterranean shrubland. Climatic niche groups (CNGs) - species ranked or classified by similar temperature or precipitation distributions - informatively described community responses under experimental manipulations. Under warming, CNGs revealed that only those species distributed in cooler regions decreased. Correspondingly, under reduced precipitation, a U-shaped treatment effect observed in the total community was the result of an abrupt decrease in wet-distributed species, followed by a delayed increase in dry-distributed species. Notably, while partially correlated, CNG explanations of community response were stronger for their respective climate parameter, suggesting some species possess specific adaptations to either warming or drought that may lead to independent selection to the two climatic variables. Our findings indicate that when climatic distributions are combined with experiments, the resulting incorporation of local plant evolutionary strategies and their changing dynamics over time leads to predictable and informative shifts in community structure under independent climate change scenarios. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  12. Latest results of OPERA

    NASA Astrophysics Data System (ADS)

    Meregaglia, A.; Opera Collaboration

    2017-04-01

    OPERA is a long baseline neutrino experiment which took data between 2008 and 2012 having for goal the observation of the νμ →ντ transition in appearance mode i.e. detecting the τ lepton. The detector was located in the underground Gran Sasso laboratory, 730 km away from the CNGS neutrino beam production at CERN. The collaboration observed 5 ντ candidates which, considering the very low expected background of 0.25 events, allowed for a discovery claim of neutrino oscillation in appearance mode at the level of 5.1 σ. Additional analyses were performed aiming at the possible observation of the νμ →νe transition, and at the search for anomalies related to the possible existence of a sterile neutrino. In this paper, after a short introduction describing the detector, the different results are presented on both oscillation channels including standard 3 flavour scenario and possible new physics.

  13. Discovery of ν_{{τ}}^{} appearance and recent results from OPERA

    NASA Astrophysics Data System (ADS)

    Fukuda, T.; Opera Collaboration

    2017-07-01

    The OPERA experiment was designed to observe {ν_{μ}}→{ν_{τ}} oscillations through {ν_{τ}} appearance at a baseline of 730km in the CNGS beam. Newly developed emulsion analysis technology allows to measure {ν_e} , {ν_{μ}} and {ν_{τ}} interactions with the largest emulsion detector ever made. OPERA has detected five {ν_{τ}} candidates, allowing to reject the background-only hypothesis at 5.1 {σ} . The parameters for standard and non-standard oscillations are measured and constrained.

  14. Discovery of νμ → ντ oscillations in the OPERA experiment

    NASA Astrophysics Data System (ADS)

    Vasina, S.

    2017-11-01

    The OPERA experiment was designed to search for νμ → ντ oscillations in appearance mode, i.e. by detecting the τ leptons produced in charge current ντ interactions. The experiment took data from 2008 to 2012 in the CNGS beam. Five observed ντ candidates together with low background 0.25 ± 0.05 allow to assess the discovery of νμ → ντ oscillations in appearance mode with significance larger than 5σ.

  15. The discovery of the appearance of νμ - ντ oscillations

    NASA Astrophysics Data System (ADS)

    Ereditato, Antonio

    2016-07-01

    Almost 20 years after the first conceptual design of the experiment, five years of running in the Gran Sasso underground laboratory (LNGS), and billions of billions muon-neutrinos sent from CERN along the CNGS beam, in 2015 the OPERA neutrino detector has allowed the long-awaited discovery of the direct transformation (oscillation) of muon-neutrinos into tau-neutrinos. This result unambiguously confirms the interpretation of the so-called atmospheric channel, after the discovery of neutrino oscillations by the Super-Kamiokande Collaboration in 1998.

  16. SAW parameters on Y-cut langasite structured materials.

    PubMed

    Puccio, Derek; Malocha, Donald C; Saldanha, Nancy; da Cunha, Mauricio Pereira

    2007-09-01

    This paper presents results and investigations of several new, man-made piezoelectric single crystal, Czochralski-grown substrate materials for surface acoustic waves (SAW) applications. These materials, langanite (LGN), langatate (LGT), Sr3TaGa3Si2O14 (STGS), Sr3NbGa3Si2O14 (SNGS), Ca3TaGa3Si2O14 (CTGS), and Ca3NbGa3Si2O14 (CNGS), have the same structure as langasite (LGS) and are of the same crystal class as quartz. These compounds are denser than quartz, resulting in lower phase velocities. They also have higher coupling. Unlike quartz and lithium niobate, there is no degradation of material properties below the material melting points resulting in the possibility of extreme high-temperature operation (> 1000 degrees C). This paper gives a summary of extracted SAW material parameters for various propagation angles on Y-cut substrates of the six materials. Parameters included are electromechanical coupling, phase velocity, transducer capacitance, metal strip reflectivity, and temperature coefficient of frequency. Using previously published fundamental material constants, extracted parameters are compared with predictions for LGT and LGN. In addition, power flow angle and fractional frequency curvature data are reported for propagation angles on CTGS and CNGS Y-cut substrates that exhibit temperature compensation near room temperature. Detailed descriptions of the SAW parameter extraction techniques are given. A discussion of the results is provided, including a comparison of extracted parameters and an overview of possible SAW applications.

  17. Recent Emulsion Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ariga, A.

    2011-10-06

    Emulsion technologies are very much developed in the last decade and still developing in both the emulsion gel and the data taking. Emulsion detectors are suitable for the neutrino experiments because they can distinguish all 3 flavors of neutrino. The OPERA experiment, a recent pillar in the emulsion experiments aiming at the first observation of the neutrino oscillation in CNGS beam in appearance mode, is running, showing the good capability to separate 3 flavor neutrino interactions. In this poster, the recent developments and prospects of the emulsions for the next generation experiments are reported.

  18. Limits on muon-neutrino to tau-neutrino oscillations induced by a sterile neutrino state obtained by OPERA at the CNGS beam

    NASA Astrophysics Data System (ADS)

    Agafonova, N.; Aleksandrov, A.; Anokhina, A.; Aoki, S.; Ariga, A.; Ariga, T.; Bender, D.; Bertolin, A.; Bodnarchuk, I.; Bozza, C.; Brugnera, R.; Buonaura, A.; Buontempo, S.; Büttner, B.; Chernyavsky, M.; Chukanov, A.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; De Serio, M.; Del Amo Sanchez, P.; Di Crescenzo, A.; Di Ferdinando, D.; Di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Dzhatdoev, T.; Ebert, J.; Ereditato, A.; Fini, R. A.; Fukuda, T.; Galati, G.; Garfagnini, A.; Goldberg, J.; Gornushkin, Y.; Grella, G.; Guler, A. M.; Gustavino, C.; Hagner, C.; Hara, T.; Hollnagel, A.; Hosseini, B.; Ishiguro, K.; Jakovcic, K.; Jollet, C.; Kamiscioglu, C.; Kamiscioglu, M.; Kim, J. H.; Kim, S. H.; Kitagawa, N.; Klicek, B.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Lauria, A.; Ljubicic, A.; Longhin, A.; Malgin, A.; Malenica, M.; Mandrioli, G.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meregaglia, A.; Mikado, S.; Monacelli, P.; Montesi, M. C.; Morishima, K.; Muciaccia, M. T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Nakatsuka, Y.; Niwa, K.; Ogawa, S.; Omura, T.; Ozaki, K.; Paoloni, A.; Paparella, L.; Park, B. D.; Park, I. G.; Pasqualini, L.; Pastore, A.; Patrizii, L.; Pessard, H.; Podgrudkov, D.; Polukhina, N.; Pozzato, M.; Pupilli, F.; Roda, M.; Roganova, T.; Rokujo, H.; Rosa, G.; Ryazhskaya, O.; Sato, O.; Schembri, A.; Shakirianova, I.; Shchedrina, T.; Sheshukov, A.; Shibuya, H.; Shiraishi, T.; Shoziyoev, G.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Spinetti, M.; Stanco, L.; Starkov, N.; Stellacci, S. M.; Stipcevic, M.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Tufanli, S.; Vilain, P.; Vladymyrov, M.; Votano, L.; Vuilleumier, J. L.; Wilquet, G.; Wonsak, B.; Yoon, C. S.; Zemskova, S.

    2015-06-01

    The OPERA experiment, exposed to the CERN to Gran Sasso ν μ beam, collected data from 2008 to 2012. Four oscillated ν τ Charged Current interaction candidates have been detected in appearance mode, which are consistent with ν μ → ν τ oscillations at the atmospheric Δ m 2 within the "standard" three-neutrino framework. In this paper, the OPERA ν τ appearance results are used to derive limits on the mixing parameters of a massive sterile neutrino.

  19. OPERA - First Beam Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakamura, M.

    2008-02-21

    OPERA is a long base-line neutrino oscillation experiment to detect tau-neutrino appearance and to prove that the origin of the atmospheric muon neutrino deficit observed by Kamiokande is the neutrino oscillation. A Hybrid emulsion detector, of which weight is about 1.3 kton, has been installed in Gran Sasso laboratory. New muon neutrino beam line, CNGS, has been constructed at CERN to send neutrinos to Gran Sasso, 730 km apart from CERN. In 2006, first neutrinos were sent from CERN to LNGS and were detected by the OPERA detector successfully as planned.

  20. Status and results from the OPERA experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ariga, Tomoko

    2011-10-06

    The OPERA experiment is aiming at the first direct detection of neutrino oscillations in appearance mode through the study of the v{sub {mu}}{yields}v{tau} channel. The OPERA detector is placed in the CNGS long baseline v{sub {mu}} beam 730 km away from the neutrino source. The analysis of a sub-sample of the data taken in the 2008-2009 runs was completed After a brief description of the beam and the experimental setup, we report on event analysis and on a first candidate event, its background estimation and statistical significance.

  1. Study of charged hadron multiplicities in charged-current neutrino-lead interactions in the OPERA detector

    NASA Astrophysics Data System (ADS)

    Agafonova, N.; Aleksandrov, A.; Anokhina, A.; Aoki, S.; Ariga, A.; Ariga, T.; Bertolin, A.; Bodnarchuk, I.; Bozza, C.; Brugnera, R.; Buonaura, A.; Buontempo, S.; Chernyavskiy, M.; Chukanov, A.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; De Serio, M.; del Amo Sanchez, P.; Di Crescenzo, A.; Di Ferdinando, D.; Di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Dzhatdoev, T.; Ebert, J.; Ereditato, A.; Fini, R. A.; Fornari, F.; Fukuda, T.; Galati, G.; Garfagnini, A.; Gentile, V.; Goldberg, J.; Gornushkin, Y.; Gorbunov, S.; Grella, G.; Guler, A. M.; Gustavino, C.; Hagner, C.; Hara, T.; Hayakawa, T.; Hollnagel, A.; Hosseini, B.; Ishiguro, K.; Jakovcic, K.; Jollet, C.; Kamiscioglu, C.; Kamiscioglu, M.; Kim, S. H.; Kitagawa, N.; Klicek, B.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Laudisio, F.; Lauria, A.; Ljubicic, A.; Longhin, A.; Loverre, P.; Malgin, A.; Malenica, M.; Mandrioli, G.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meregaglia, A.; Mikado, S.; Miyanishi, M.; Mizutani, F.; Monacelli, P.; Montesi, M. C.; Morishima, K.; Muciaccia, M. T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Niwa, K.; Okateva, N.; Ogawa, S.; Ozaki, K.; Paoloni, A.; Paparella, L.; Park, B. D.; Pasqualini, L.; Pastore, A.; Patrizii, L.; Pessard, H.; Podgrudkov, D.; Polukhina, N.; Pozzato, M.; Pupilli, F.; Roda, M.; Roganova, T.; Rokujo, H.; Rosa, G.; Ryazhskaya, O.; Sato, O.; Schembri, A.; Shakirianova, I.; Shchedrina, T.; Shibuya, H.; Shibayama, E.; Shiraishi, T.; Simone, S.; Sirignano, C.; Sirri, G.; Sotnikov, A.; Spinetti, M.; Stanco, L.; Starkov, N.; Stellacci, S. M.; Stipcevic, M.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Vasina, S.; Vilain, P.; Voevodina, E.; Votano, L.; Vuilleumier, J. L.; Wilquet, G.; Wonsak, B.; Yoon, C. S.

    2018-01-01

    The OPERA experiment was designed to search for ν _{μ } → ν _{τ } oscillations in appearance mode through the direct observation of tau neutrinos in the CNGS neutrino beam. In this paper, we report a study of the multiplicity of charged particles produced in charged-current neutrino interactions in lead. We present charged hadron average multiplicities, their dispersion and investigate the KNO scaling in different kinematical regions. The results are presented in detail in the form of tables that can be used in the validation of Monte Carlo generators of neutrino-lead interactions.

  2. The OPERA experiment

    NASA Astrophysics Data System (ADS)

    Agafonova, N.; Aleksandrov, A.; Anokhina, A.; Aoki, S.; Ariga, A.; Ariga, T.; Bender, D.; Bertolin, A.; Bozza, C.; Brugnera, R.; Buonaura, A.; Buontempo, S.; Büttner, B.; Chernyavsky, M.; Chukanov, A.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; De Serio, M.; Del Amo Sanchez, P.; Di Crescenzo, A.; Di Ferdinando, D.; Di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Dzhatdoev, T.; Ebert, J.; Ereditato, A.; Fini, R. A.; Fukuda, T.; Galati, G.; Garfagnini, A.; Giacomelli, G.; Göllnitz, C.; Goldberg, J.; Gornushkin, Y.; Grella, G.; Guler, M.; Gustavino, C.; Hagner, C.; Hara, T.; Hollnagel, A.; Hosseini, B.; Ishida, H.; Ishiguro, K.; Jakovcic, K.; Jollet, C.; Kamiscioglu, C.; Kamiscioglu, M.; Kawada, J.; Kim, J. H.; Kim, S. H.; Kitagawa, N.; Klicek, B.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Lauria, A.; Lenkeit, J.; Ljubicic, A.; Longhin, A.; Loverre, P.; Malgin, A.; Malenica, M.; Mandrioli, G.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meregaglia, A.; Mikado, S.; Monacelli, P.; Montesi, M. C.; Morishima, K.; Muciaccia, M. T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Nakatsuka, Y.; Niwa, K.; Ogawa, S.; Okateva, N.; Olshevsky, A.; Omura, T.; Ozaki, K.; Paoloni, A.; Park, B. D.; Park, I. G.; Pasqualini, L.; Pastore, A.; Patrizii, L.; Pessard, H.; Pistillo, C.; Podgrudkov, D.; Polukhina, N.; Pozzato, M.; Pupilli, F.; Roda, M.; Rokujo, H.; Roganova, T.; Rosa, G.; Ryazhskaya, O.; Sato, O.; Schembri, A.; Shakiryanova, I.; Shchedrina, T.; Sheshukov, A.; Shibuya, H.; Shiraishi, T.; Shoziyoev, G.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Spinetti, M.; Stanco, L.; Starkov, N.; Stellacci, S. M.; Stipcevic, M.; Strauss, T.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Tufanli, S.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J. L.; Wilquet, G.; Wonsak, B.; Yoon, C. S.; Zemskova, S.; Zghiche, A.

    2015-10-01

    The OPERA experiment was designed to study νμ →ντ oscillations in appearance mode using the CERN to Gran Sasso high energy neutrino beam. From 2008 to 2012, 19505 CNGS neutrino interactions were recorded in the OPERA detector. At the present status of the analysis, 4 ντ candidate events have been observed, establishing the oscillation mechanism in the atmospheric sector with a significance of 4.2 σ. The oscillation analysis will be presented in detail and the candidate events will be described. The final measurement of the atmospheric muon charge ratio in the TeV region will be also reported.

  3. νμ → ν e oscillations search in the OPERA experiment

    NASA Astrophysics Data System (ADS)

    Zemskova, S.

    2016-11-01

    The tracking capabilities of the OPERA detector allow to reconstruct τ-leptons and electrons. It gives a possibility to observe νμ → ντ oscillations in the appearance mode and to study νμ → ν e oscillations in the νμ CNGS beam. Current results on νμ → ν e channel in the three-flavour mixing model are presented. The same data allow to constrain the presence of additional sterile neutrino states. The analysis of the full 2008-2012 OPERA data set and work on its improvement are going on. Details of the achievements are presented.

  4. DMRT gene cluster analysis in the platypus: new insights into genomic organization and regulatory regions.

    PubMed

    El-Mogharbel, Nisrine; Wakefield, Matthew; Deakin, Janine E; Tsend-Ayush, Enkhjargal; Grützner, Frank; Alsop, Amber; Ezaz, Tariq; Marshall Graves, Jennifer A

    2007-01-01

    We isolated and characterized a cluster of platypus DMRT genes and compared their arrangement, location, and sequence across vertebrates. The DMRT gene cluster on human 9p24.3 harbors, in order, DMRT1, DMRT3, and DMRT2, which share a DM domain. DMRT1 is highly conserved and involved in sexual development in vertebrates, and deletions in this region cause sex reversal in humans. Sequence comparisons of DMRT genes between species have been valuable in identifying exons, control regions, and conserved nongenic regions (CNGs). The addition of platypus sequences is expected to be particularly valuable, since monotremes fill a gap in the vertebrate genome coverage. We therefore isolated and fully sequenced platypus BAC clones containing DMRT3 and DMRT2 as well as DMRT1 and then generated multispecies alignments and ran prediction programs followed by experimental verification to annotate this gene cluster. We found that the three genes have 58-66% identity to their human orthologues, lie in the same order as in other vertebrates, and colocate on 1 of the 10 platypus sex chromosomes, X5. We also predict that optimal annotation of the newly sequenced platypus genome will be challenging. The analysis of platypus sequence revealed differences in structure and sequence of the DMRT gene cluster. Multispecies comparison was particularly effective for detecting CNGs, revealing several novel potential regulatory regions within DMRT3 and DMRT2 as well as DMRT1. RT-PCR indicated that platypus DMRT1 and DMRT3 are expressed specifically in the adult testis (and not ovary), but DMRT2 has a wider expression profile, as it does for other mammals. The platypus DMRT1 expression pattern, and its location on an X chromosome, suggests an involvement in monotreme sexual development.

  5. Precise 3D Track Reconstruction Algorithm for the ICARUS T600 Liquid Argon Time Projection Chamber Detector

    DOE PAGES

    Antonello, M.; Baibussinov, B.; Benetti, P.; ...

    2013-01-15

    Liquid Argon Time Projection Chamber (LAr TPC) detectors offer charged particle imaging capability with remarkable spatial resolution. Precise event reconstruction procedures are critical in order to fully exploit the potential of this technology. In this paper we present a new, general approach to 3D reconstruction for the LAr TPC with a practical application to the track reconstruction. The efficiency of the method is evaluated on a sample of simulated tracks. We present also the application of the method to the analysis of stopping particle tracks collected during the ICARUS T600 detector operation with the CNGS neutrino beam.

  6. Deletions involving long-range conserved nongenic sequences upstream and downstream of FOXL2 as a novel disease-causing mechanism in blepharophimosis syndrome.

    PubMed

    Beysen, D; Raes, J; Leroy, B P; Lucassen, A; Yates, J R W; Clayton-Smith, J; Ilyina, H; Brooks, S Sklower; Christin-Maitre, S; Fellous, M; Fryns, J P; Kim, J R; Lapunzina, P; Lemyre, E; Meire, F; Messiaen, L M; Oley, C; Splitt, M; Thomson, J; Van de Peer, Y; Veitia, R A; De Paepe, A; De Baere, E

    2005-08-01

    The expression of a gene requires not only a normal coding sequence but also intact regulatory regions, which can be located at large distances from the target genes, as demonstrated for an increasing number of developmental genes. In previous mutation studies of the role of FOXL2 in blepharophimosis syndrome (BPES), we identified intragenic mutations in 70% of our patients. Three translocation breakpoints upstream of FOXL2 in patients with BPES suggested a position effect. Here, we identified novel microdeletions outside of FOXL2 in cases of sporadic and familial BPES. Specifically, four rearrangements, with an overlap of 126 kb, are located 230 kb upstream of FOXL2, telomeric to the reported translocation breakpoints. Moreover, the shortest region of deletion overlap (SRO) contains several conserved nongenic sequences (CNGs) harboring putative transcription-factor binding sites and representing potential long-range cis-regulatory elements. Interestingly, the human region orthologous to the 12-kb sequence deleted in the polled intersex syndrome in goat, which is an animal model for BPES, is contained in this SRO, providing evidence of human-goat conservation of FOXL2 expression and of the mutational mechanism. Surprisingly, in a fifth family with BPES, one rearrangement was found downstream of FOXL2. In addition, we report nine novel rearrangements encompassing FOXL2 that range from partial gene deletions to submicroscopic deletions. Overall, genomic rearrangements encompassing or outside of FOXL2 account for 16% of all molecular defects found in our families with BPES. In summary, this is the first report of extragenic deletions in BPES, providing further evidence of potential long-range cis-regulatory elements regulating FOXL2 expression. It contributes to the enlarging group of developmental diseases caused by defective distant regulation of gene expression. Finally, we demonstrate that CNGs are candidate regions for genomic rearrangements in developmental genes.

  7. Deletions Involving Long-Range Conserved Nongenic Sequences Upstream and Downstream of FOXL2 as a Novel Disease-Causing Mechanism in Blepharophimosis Syndrome

    PubMed Central

    Beysen, D.; Raes, J.; Leroy, B. P.; Lucassen, A.; Yates, J. R. W.; Clayton-Smith, J.; Ilyina, H.; Brooks, S. Sklower; Christin-Maitre, S.; Fellous, M.; Fryns, J. P.; Kim, J. R.; Lapunzina, P.; Lemyre, E.; Meire, F.; Messiaen, L. M.; Oley, C.; Splitt, M.; Thomson, J.; Peer, Y. Van de; Veitia, R. A.; De Paepe, A.; De Baere, E.

    2005-01-01

    The expression of a gene requires not only a normal coding sequence but also intact regulatory regions, which can be located at large distances from the target genes, as demonstrated for an increasing number of developmental genes. In previous mutation studies of the role of FOXL2 in blepharophimosis syndrome (BPES), we identified intragenic mutations in 70% of our patients. Three translocation breakpoints upstream of FOXL2 in patients with BPES suggested a position effect. Here, we identified novel microdeletions outside of FOXL2 in cases of sporadic and familial BPES. Specifically, four rearrangements, with an overlap of 126 kb, are located 230 kb upstream of FOXL2, telomeric to the reported translocation breakpoints. Moreover, the shortest region of deletion overlap (SRO) contains several conserved nongenic sequences (CNGs) harboring putative transcription-factor binding sites and representing potential long-range cis-regulatory elements. Interestingly, the human region orthologous to the 12-kb sequence deleted in the polled intersex syndrome in goat, which is an animal model for BPES, is contained in this SRO, providing evidence of human-goat conservation of FOXL2 expression and of the mutational mechanism. Surprisingly, in a fifth family with BPES, one rearrangement was found downstream of FOXL2. In addition, we report nine novel rearrangements encompassing FOXL2 that range from partial gene deletions to submicroscopic deletions. Overall, genomic rearrangements encompassing or outside of FOXL2 account for 16% of all molecular defects found in our families with BPES. In summary, this is the first report of extragenic deletions in BPES, providing further evidence of potential long-range cis-regulatory elements regulating FOXL2 expression. It contributes to the enlarging group of developmental diseases caused by defective distant regulation of gene expression. Finally, we demonstrate that CNGs are candidate regions for genomic rearrangements in developmental genes. PMID:15962237

  8. Observation of tau neutrino appearance in the CNGS beam with the OPERA experiment

    NASA Astrophysics Data System (ADS)

    Opera Collaboration; Agafonova, N.; Aleksandrov, A.; Anokhina, A.; Aoki, S.; Ariga, A.; Ariga, T.; Asada, T.; Bender, D.; Bertolin, A.; Bozza, C.; Brugnera, R.; Buonaura, A.; Buontempo, S.; Büttner, B.; Chernyavsky, M.; Chukanov, A.; Consiglio, L.; D'Ambrosio, N.; de Lellis, G.; de Serio, M.; Del Amo Sanchez, P.; di Crescenzo, A.; di Ferdinando, D.; di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Dzhatdoev, T.; Ebert, J.; Ereditato, A.; Fini, R. A.; Fukuda, T.; Galati, G.; Garfagnini, A.; Giacomelli, G.; Goellnitz, C.; Goldberg, J.; Gornushkin, Y.; Grella, G.; Guler, M.; Gustavino, C.; Hagner, C.; Hara, T.; Hayakawa, T.; Hollnagel, A.; Hosseini, B.; Ishida, H.; Ishiguro, K.; Jakovcic, K.; Jollet, C.; Kamiscioglu, C.; Kamiscioglu, M.; Katsuragawa, T.; Kawada, J.; Kawahara, H.; Kim, J. H.; Kim, S. H.; Kitagawa, N.; Klicek, B.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Lauria, A.; Lenkeit, J.; Ljubicic, A.; Longhin, A.; Loverre, P.; Malenica, M.; Malgin, A.; Mandrioli, G.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meregaglia, A.; Meyer, M.; Mikado, S.; Miyanishi, M.; Monacelli, P.; Montesi, M. C.; Morishima, K.; Muciaccia, M. T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Nakatsuka, Y.; Niwa, K.; Ogawa, S.; Okateva, N.; Olshevsky, A.; Omura, T.; Ozaki, K.; Paoloni, A.; Park, B. D.; Park, I. G.; Pasqualini, L.; Pastore, A.; Patrizii, L.; Pessard, H.; Pistillo, C.; Podgrudkov, D.; Polukhina, N.; Pozzato, M.; Pupilli, F.; Roda, M.; Roganova, T.; Rokujo, H.; Rosa, G.; Ryazhskaya, O.; Sato, O.; Schembri, A.; Shakiryanova, I.; Shchedrina, T.; Sheshukov, A.; Shibuya, H.; Shiraishi, T.; Shoziyoev, G.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Spinetti, M.; Stanco, L.; Starkov, N.; Stellacci, S. M.; Stipcevic, M.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Tufanli, S.; Umemoto, A.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J. L.; Wilquet, G.; Wonsak, B.; Yoon, C. S.; Yaguchi, I.; Yoshimoto, M.; Zemskova, S.; Zghiche, A.

    2014-10-01

    The OPERA experiment is searching for ν _μ rArr ν _tau oscillations in appearance mode, i.e., via the direct detection of tau leptons in ν _tau charged-current interactions. The evidence of ν _μ rArr ν _tau appearance has been previously reported with three ν _tau candidate events using a sub-sample of data from the 2008-2012 runs. We report here a fourth ν _tau candidate event, with the tau decaying into a hadron, found after adding the 2012 run events without any muon in the final state to the data sample. Given the number of analyzed events and the low background, ν _μ rArr ν _tau oscillations are established with a significance of 4.2σ.

  9. Latest results on νμ → ντ oscillations from the OPERA experiment

    NASA Astrophysics Data System (ADS)

    Komatsu, Masahiro; OPERA Collaboration

    2016-04-01

    The OPERA experiment is designed to prove neutrino oscillations in the νμ to ντ channel through the direct observation of the tau lepton in tau neutrino charged current interactions. The experiment has accumulated data for five years, from 2008 to 2012, with the CERN Neutrinos to Gran Sasso (CNGS), an almost pure νμ beam. In the last two years, a very large amount of the data accumulated in the nuclear emulsions has been analyzed. The latest results on oscillations with the increased statistics, which include a fourth tau neutrino candidate event, will be presented. Given the extremely low expected background, this result corresponds to the observation of the oscillation process with a four sigma level significance.

  10. Short-lived particle search procedure in the OPERA experiment. Application to charm decays

    NASA Astrophysics Data System (ADS)

    del Amo Sánchez, Pablo; OPERA Collaboration

    2016-04-01

    The OPERA experiment has recently provided evidence of νμ →ντ neutrino oscillations in appearance mode through the detection of tau leptons produced in ντ Charged Current interactions. The OPERA detector collected data from 2008 to 2012, when it was exposed to the CNGS muon neutrino beam from CERN to Gran Sasso, 730 km away from the source. We report on the search procedure for short-lived particles and on its validation with charmed hadron decays. The latter, produced in about 4% of the neutrino interactions in OPERA, are an important background to the νμ →ντ channel and an ideal control sample as their decay exhibits topological and kinematical features strongly resembling the tau's decay.

  11. Discovery of τ Neutrino Appearance in the CNGS Neutrino Beam with the OPERA Experiment.

    PubMed

    Agafonova, N; Aleksandrov, A; Anokhina, A; Aoki, S; Ariga, A; Ariga, T; Bender, D; Bertolin, A; Bodnarchuk, I; Bozza, C; Brugnera, R; Buonaura, A; Buontempo, S; Büttner, B; Chernyavsky, M; Chukanov, A; Consiglio, L; D'Ambrosio, N; De Lellis, G; De Serio, M; Del Amo Sanchez, P; Di Crescenzo, A; Di Ferdinando, D; Di Marco, N; Dmitrievski, S; Dracos, M; Duchesneau, D; Dusini, S; Dzhatdoev, T; Ebert, J; Ereditato, A; Fini, R A; Fornari, F; Fukuda, T; Galati, G; Garfagnini, A; Goldberg, J; Gornushkin, Y; Grella, G; Guler, A M; Gustavino, C; Hagner, C; Hara, T; Hayakawa, H; Hollnagel, A; Hosseini, B; Ishiguro, K; Jakovcic, K; Jollet, C; Kamiscioglu, C; Kamiscioglu, M; Kim, J H; Kim, S H; Kitagawa, N; Klicek, B; Kodama, K; Komatsu, M; Kose, U; Kreslo, I; Laudisio, F; Lauria, A; Ljubicic, A; Longhin, A; Loverre, P F; Malgin, A; Malenica, M; Mandrioli, G; Matsuo, T; Matsushita, T; Matveev, V; Mauri, N; Medinaceli, E; Meregaglia, A; Mikado, S; Miyanishi, M; Mizutani, F; Monacelli, P; Montesi, M C; Morishima, K; Muciaccia, M T; Naganawa, N; Naka, T; Nakamura, M; Nakano, T; Nakatsuka, Y; Niwa, K; Ogawa, S; Olchevsky, A; Omura, T; Ozaki, K; Paoloni, A; Paparella, L; Park, B D; Park, I G; Pasqualini, L; Pastore, A; Patrizii, L; Pessard, H; Pistillo, C; Podgrudkov, D; Polukhina, N; Pozzato, M; Pupilli, F; Roda, M; Roganova, T; Rokujo, H; Rosa, G; Ryazhskaya, O; Sato, O; Schembri, A; Schmidt-Parzefall, W; Shakirianova, I; Shchedrina, T; Sheshukov, A; Shibuya, H; Shiraishi, T; Shoziyoev, G; Simone, S; Sioli, M; Sirignano, C; Sirri, G; Sotnikov, A; Spinetti, M; Stanco, L; Starkov, N; Stellacci, S M; Stipcevic, M; Strolin, P; Takahashi, S; Tenti, M; Terranova, F; Tioukov, V; Tufanli, S; Vilain, P; Vladymyrov, M; Votano, L; Vuilleumier, J L; Wilquet, G; Wonsak, B; Yoon, C S; Zemskova, S

    2015-09-18

    The OPERA experiment was designed to search for ν_{μ}→ν_{τ} oscillations in appearance mode, i.e., by detecting the τ leptons produced in charged current ν_{τ} interactions. The experiment took data from 2008 to 2012 in the CERN Neutrinos to Gran Sasso beam. The observation of the ν_{μ}→ν_{τ} appearance, achieved with four candidate events in a subsample of the data, was previously reported. In this Letter, a fifth ν_{τ} candidate event, found in an enlarged data sample, is described. Together with a further reduction of the expected background, the candidate events detected so far allow us to assess the discovery of ν_{μ}→ν_{τ} oscillations in appearance mode with a significance larger than 5σ.

  12. Evidence for νμ→ντ appearance in the CNGS neutrino beam with the OPERA experiment

    NASA Astrophysics Data System (ADS)

    Agafonova, N.; Aleksandrov, A.; Anokhina, A.; Aoki, S.; Ariga, A.; Ariga, T.; Asada, T.; Autiero, D.; Ben Dhahbi, A.; Badertscher, A.; Bender, D.; Bertolin, A.; Bozza, C.; Brugnera, R.; Brunet, F.; Brunetti, G.; Buonaura, A.; Buontempo, S.; Büttner, B.; Chaussard, L.; Chernyavsky, M.; Chiarella, V.; Chukanov, A.; Consiglio, L.; D'Ambrosio, N.; de Lellis, G.; de Serio, M.; Del Amo Sanchez, P.; di Crescenzo, A.; di Ferdinando, D.; di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Dzhatdoev, T.; Ebert, J.; Ereditato, A.; Favier, J.; Ferber, T.; Ferone, G.; Fini, R. A.; Fukuda, T.; Galati, G.; Garfagnini, A.; Giacomelli, G.; Goellnitz, C.; Goldberg, J.; Gornushkin, Y.; Grella, G.; Grianti, F.; Guler, M.; Gustavino, C.; Hagner, C.; Hakamata, K.; Hara, T.; Hayakawa, T.; Hierholzer, M.; Hollnagel, A.; Hosseini, B.; Ishida, H.; Ishiguro, K.; Ishikawa, M.; Jakovcic, K.; Jollet, C.; Kamiscioglu, C.; Kamiscioglu, M.; Katsuragawa, T.; Kawada, J.; Kawahara, H.; Kim, J. H.; Kim, S. H.; Kimura, M.; Kitagawa, N.; Klicek, B.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Lauria, A.; Lenkeit, J.; Ljubicic, A.; Longhin, A.; Loverre, P.; Malgin, A.; Mandrioli, G.; Marteau, J.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meregaglia, A.; Migliozzi, P.; Mikado, S.; Miyanishi, M.; Miyashita, E.; Monacelli, P.; Montesi, M. C.; Morishima, K.; Muciaccia, M. T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Nakatsuka, Y.; Niwa, K.; Ogawa, S.; Okateva, N.; Olshevsky, A.; Omura, T.; Ozaki, K.; Paoloni, A.; Park, B. D.; Park, I. G.; Pastore, A.; Patrizii, L.; Pennacchio, E.; Pessard, H.; Pistillo, C.; Podgrudkov, D.; Polukhina, N.; Pozzato, M.; Pretzl, K.; Pupilli, F.; Rescigno, R.; Roda, M.; Rokujo, H.; Roganova, T.; Rosa, G.; Rostovtseva, I.; Rubbia, A.; Ryazhskaya, O.; Sato, O.; Sato, Y.; Schembri, A.; Schmidt-Parzefal, W.; Shakiryanova, I.; Shchedrina, T.; Sheshukov, A.; Shibuya, H.; Shiraishi, T.; Shoziyoev, G.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Spinetti, M.; Stanco, L.; Starkov, N.; Stellacci, S. M.; Stipcevic, M.; Strauss, T.; Strolin, P.; Suzuki, K.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Tufanli, S.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J. L.; Wilquet, G.; Wonsak, B.; Yoon, C. S.; Yoshida, J.; Yoshimoto, M.; Zaitsev, Y.; Zemskova, S.; Zghiche, A.; Opera Collaboration

    2014-03-01

    The OPERA experiment is designed to search for νμ→ντ oscillations in appearance mode, i.e., through the direct observation of the τ lepton in ντ-charged current interactions. The experiment has taken data for five years, since 2008, with the CERN Neutrino to Gran Sasso beam. Previously, two ντ candidates with a τ decaying into hadrons were observed in a subsample of data of the 2008-2011 runs. Here we report the observation of a third ντ candidate in the τ-→μ- decay channel coming from the analysis of a subsample of the 2012 run. Taking into account the estimated background, the absence of νμ→ντ oscillations is excluded at the 3.4 σ level.

  13. Discovery of τ Neutrino Appearance in the CNGS Neutrino Beam with the OPERA Experiment

    NASA Astrophysics Data System (ADS)

    Agafonova, N.; Aleksandrov, A.; Anokhina, A.; Aoki, S.; Ariga, A.; Ariga, T.; Bender, D.; Bertolin, A.; Bodnarchuk, I.; Bozza, C.; Brugnera, R.; Buonaura, A.; Buontempo, S.; Büttner, B.; Chernyavsky, M.; Chukanov, A.; Consiglio, L.; D'Ambrosio, N.; de Lellis, G.; de Serio, M.; Del Amo Sanchez, P.; di Crescenzo, A.; di Ferdinando, D.; di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Dzhatdoev, T.; Ebert, J.; Ereditato, A.; Fini, R. A.; Fornari, F.; Fukuda, T.; Galati, G.; Garfagnini, A.; Goldberg, J.; Gornushkin, Y.; Grella, G.; Guler, A. M.; Gustavino, C.; Hagner, C.; Hara, T.; Hayakawa, H.; Hollnagel, A.; Hosseini, B.; Ishiguro, K.; Jakovcic, K.; Jollet, C.; Kamiscioglu, C.; Kamiscioglu, M.; Kim, J. H.; Kim, S. H.; Kitagawa, N.; Klicek, B.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Laudisio, F.; Lauria, A.; Ljubicic, A.; Longhin, A.; Loverre, P. F.; Malgin, A.; Malenica, M.; Mandrioli, G.; Matsuo, T.; Matsushita, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meregaglia, A.; Mikado, S.; Miyanishi, M.; Mizutani, F.; Monacelli, P.; Montesi, M. C.; Morishima, K.; Muciaccia, M. T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Nakatsuka, Y.; Niwa, K.; Ogawa, S.; Olchevsky, A.; Omura, T.; Ozaki, K.; Paoloni, A.; Paparella, L.; Park, B. D.; Park, I. G.; Pasqualini, L.; Pastore, A.; Patrizii, L.; Pessard, H.; Pistillo, C.; Podgrudkov, D.; Polukhina, N.; Pozzato, M.; Pupilli, F.; Roda, M.; Roganova, T.; Rokujo, H.; Rosa, G.; Ryazhskaya, O.; Sato, O.; Schembri, A.; Schmidt-Parzefall, W.; Shakirianova, I.; Shchedrina, T.; Sheshukov, A.; Shibuya, H.; Shiraishi, T.; Shoziyoev, G.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Sotnikov, A.; Spinetti, M.; Stanco, L.; Starkov, N.; Stellacci, S. M.; Stipcevic, M.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Tufanli, S.; Vilain, P.; Vladymyrov, M.; Votano, L.; Vuilleumier, J. L.; Wilquet, G.; Wonsak, B.; Yoon, C. S.; Zemskova, S.; Opera Collaboration

    2015-09-01

    The OPERA experiment was designed to search for νμ→ντ oscillations in appearance mode, i.e., by detecting the τ leptons produced in charged current ντ interactions. The experiment took data from 2008 to 2012 in the CERN Neutrinos to Gran Sasso beam. The observation of the νμ→ντ appearance, achieved with four candidate events in a subsample of the data, was previously reported. In this Letter, a fifth ντ candidate event, found in an enlarged data sample, is described. Together with a further reduction of the expected background, the candidate events detected so far allow us to assess the discovery of νμ→ντ oscillations in appearance mode with a significance larger than 5 σ .

  14. Recent results of the OPERA experiment

    NASA Astrophysics Data System (ADS)

    Pupilli, F.

    2016-06-01

    The OPERA experiment at the Gran Sasso underground laboratory has been designed to study the νµ → ντ oscillation in appearance mode in the CNGS neutrino beam. Five ντ candidate events have been confirmed so far, using a sub-sample of data from the 2008-2012 runs. Given the low background level, the discovery of νµ → ντ oscillations has been established with a significance of 5.1 σ. In this paper the data analysis is discussed, with emphasis on the background constraints obtained by using dedicated data-driven control samples. The analysis of the τ neutrino and electron neutrino data in the framework of the 3+1 sterile neutrino model are presented. The measurement of the muon charge ratio in the collected cosmic ray sample is also reported.

  15. More Results from the Opera Experiment at the Gran Sasso Underground Lab

    NASA Astrophysics Data System (ADS)

    Kamiscioglu, Mustafa

    The OPERA experiment reached its main goal by proving the appearance of ντ in the CNGS νμ beam. Five ντ candidates fulfilling the analysis defined in the proposal were detected with a S/B ratio of about ten allowing to reject the null hypothesis at 5.1σ. The search has been extended by loosening the selection criteria in order to obtain a statistically enhanced, lower purity, signal sample. One such interesting neutrino interaction with a double vertex topology having a high probability of being a ντ interaction with charm production is reported. Based on the enlarged data sample the estimation of Δm232 in appearance mode is presented. The search for νe interactions has been extended over the full data set with a more than twofold increase in statistics with respect to published data. The analysis of the νμ → νe channel is updated and the implications of the electron neutrino sample in the framework of the 3+1 neutrino model is discussed. An analysis of νμ → ντ interactions in the framework of the sterile neutrino model has also been performed. Finally, the results of the study of charged hadron multiplicity distributions is presented.

  16. Applications of High Intensity Proton Accelerators

    NASA Astrophysics Data System (ADS)

    Raja, Rajendran; Mishra, Shekhar

    2010-06-01

    Superconducting radiofrequency linac development at Fermilab / S. D. Holmes -- Rare muon decay experiments / Y. Kuno -- Rare kaon decays / D. Bryman -- Muon collider / R. B. Palmer -- Neutrino factories / S. Geer -- ADS and its potential / J.-P. Revol -- ADS history in the USA / R. L. Sheffield and E. J. Pitcher -- Accelerator driven transmutation of waste: high power accelerator for the European ADS demonstrator / J. L. Biarrotte and T. Junquera -- Myrrha, technology development for the realisation of ADS in EU: current status & prospects for realisation / R. Fernandez ... [et al.] -- High intensity proton beam production with cyclotrons / J. Grillenberger and M. Seidel -- FFAG for high intensity proton accelerator / Y. Mori -- Kaon yields for 2 to 8 GeV proton beams / K. K. Gudima, N. V. Mokhov and S. I. Striganov -- Pion yield studies for proton driver beams of 2-8 GeV kinetic energy for stopped muon and low-energy muon decay experiments / S. I. Striganov -- J-Parc accelerator status and future plans / H. Kobayashi -- Simulation and verification of DPA in materials / N. V. Mokhov, I. L. Rakhno and S. I. Striganov -- Performance and operational experience of the CNGS facility / E. Gschwendtner -- Particle physics enabled with super-conducting RF technology - summary of working group 1 / D. Jaffe and R. Tschirhart -- Proton beam requirements for a neutrino factory and muon collider / M. S. Zisman -- Proton bunching options / R. B. Palmer -- CW SRF H linac as a proton driver for muon colliders and neutrino factories / M. Popovic, C. M. Ankenbrandt and R. P. Johnson -- Rapid cycling synchrotron option for Project X / W. Chou -- Linac-based proton driver for a neutrino factory / R. Garoby ... [et al.] -- Pion production for neutrino factories and muon colliders / N. V. Mokhov ... [et al.] -- Proton bunch compression strategies / V. Lebedev -- Accelerator test facility for muon collider and neutrino factory R&D / V. Shiltsev -- The superconducting RF linac for muon collider and neutrino factory - summary of working group 2 / J. Galambos, R. Garoby and S. Geer -- Prospects for a very high power CW SRF linac / R. A. Rimmer -- Indian accelerator program for ADS applications / V. C. Sahni and P. Singh -- Ion accelerator activities at VECC (particularly, operating at low temperature) / R. K. Bhandari -- Chinese efforts in high intensity proton accelerators / S. Fu, J. Wang and S. Fang -- ADSR activity in the UK / R. J. Barlow -- ADS development in Japan / K. Kikuchi -- Project-X, SRF, and very large power stations / C. M. Ankenbrandt, R. P. Johnson and M. Popovic -- Power production and ADS / R. Raja -- Experimental neutron source facility based on accelerator driven system / Y. Gohar -- Transmutation mission / W. S. Yang -- Safety performance and issues / J. E. Cahalan -- Spallation target design for accelerator-driven systems / Y. Gohar -- Design considerations for accelerator transmutation of waste system / W. S. Yang -- Japan ADS program / T. Sasa -- Overview of members states' and IAEA activities in the field of Accelerator Driven Systems (ADS) / A. Stanculescu -- Linac for ADS applications - accelerator technologies / R. W. Garnett and R. L. Sheffield -- SRF linacs and accelerator driven sub-critical systems - summary working groups 3 & 4 / J. Delayen -- Production of Actinium-225 via high energy proton induced spallation of Thorium-232 / J. Harvey ... [et al.] -- Search for the electric dipole moment of Radium-225 / R. J. Holt, Z.-T. Lu and R. Mueller -- SRF linac and material science and medicine - summary of working group 5 / J. Nolen, E. Pitcher and H. Kirk.

  17. Recent results of the OPERA experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pupilli, F.

    The OPERA experiment at the Gran Sasso underground laboratory has been designed to study the ν{sub µ} → ν{sub τ} oscillation in appearance mode in the CNGS neutrino beam. Five ν{sub τ} candidate events have been confirmed so far, using a sub-sample of data from the 2008-2012 runs. Given the low background level, the discovery of ν{sub µ} → ν{sub τ} oscillations has been established with a significance of 5.1 σ. In this paper the data analysis is discussed, with emphasis on the background constraints obtained by using dedicated data-driven control samples. The analysis of the τ neutrino and electronmore » neutrino data in the framework of the 3+1 sterile neutrino model are presented. The measurement of the muon charge ratio in the collected cosmic ray sample is also reported.« less

  18. Determination of the muon charge sign with the dipolar spectrometers of the OPERA experiment

    NASA Astrophysics Data System (ADS)

    Agafonova, N.; Aleksandrov, A.; Anokhina, A.; Aoki, S.; Ariga, A.; Ariga, T.; Bender, D.; Bertolin, A.; Bozza, C.; Brugnera, R.; Buonaura, A.; Buontempo, S.; Büttner, B.; Chernyavsky, M.; Chukanov, A.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; De Serio, M.; Del Amo Sanchez, P.; Di Crescenzo, A.; Di Ferdinando, D.; Di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Dzhatdoev, T.; Ebert, J.; Ereditato, A.; Fini, R. A.; Fukuda, T.; Galati, G.; Garfagnini, A.; Giacomelli, G.; Göllnitz, C.; Goldberg, J.; Goloubkov, D.; Gornushkin, Y.; Grella, G.; Guler, M.; Gustavino, C.; Hagner, C.; Hara, T.; Hollnagel, A.; Hosseini, B.; Ishida, H.; Ishiguro, K.; Jakovcic, K.; Jollet, C.; Kamiscioglu, C.; Kamiscioglu, M.; Kawada, J.; Kim, J. H.; Kim, S. H.; Kitagawa, N.; Klicek, B.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Lauria, A.; Lenkeit, J.; Ljubicic, A.; Longhin, A.; Loverre, P.; Malgin, A.; Malenica, M.; Mandrioli, G.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meregaglia, A.; Meyer, M.; Mikado, S.; Monacelli, P.; Montesi, M. C.; Morishima, K.; Muciaccia, M. T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Nakatsuka, Y.; Niwa, K.; Ogawa, S.; Okateva, N.; Olshevsky, A.; Omura, T.; Ozaki, K.; Paoloni, A.; Park, B. D.; Park, I. G.; Pasqualini, L.; Pastore, A.; Patrizii, L.; Pessard, H.; Pistillo, C.; Podgrudkov, D.; Polukhina, N.; Pozzato, M.; Pupilli, F.; Roda, M.; Rokujo, H.; Roganova, T.; Rosa, G.; Rostovtseva, I.; Ryazhskaya, O.; Sato, O.; Sato, Y.; Schembri, A.; Shakiryanova, I.; Shchedrina, T.; Sheshukov, A.; Shibuya, H.; Shiraishi, T.; Shoziyoev, G.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Spinetti, M.; Stanco, L.; Starkov, N.; Stellacci, S. M.; Stipcevic, M.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Tufanli, S.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J. L.; Wilquet, G.; Wonsak, B.; Yoon, C. S.; Zaitsev, Y.; Zemskova, S.; Zghiche, A.

    2016-07-01

    The OPERA long-baseline neutrino-oscillation experiment has observed the direct appearance of ντ in the CNGS νμ beam. Two large muon magnetic spectrometers are used to identify muons produced in the τ leptonic decay and in νμ CC interactions by measuring their charge and momentum. Besides the kinematic analysis of the τ decays, background resulting from the decay of charmed particles produced in νμ CC interactions is reduced by efficiently identifying the muon track. A new method for the charge sign determination has been applied, via a weighted angular matching of the straight track-segments reconstructed in the different parts of the dipole magnets. Results obtained for Monte Carlo and real data are presented. Comparison with a method where no matching is used shows a significant reduction of up to 40% of the fraction of wrongly determined charges.

  19. Measurement of the TeV atmospheric muon charge ratio with the complete OPERA data set

    NASA Astrophysics Data System (ADS)

    Agafonova, N.; Aleksandrov, A.; Anokhina, A.; Aoki, S.; Ariga, A.; Ariga, T.; Bender, D.; Bertolin, A.; Bozza, C.; Brugnera, R.; Buonaura, A.; Buontempo, S.; Büttner, B.; Chernyavsky, M.; Chukanov, A.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; De Serio, M.; Del Amo Sanchez, P.; Di Crescenzo, A.; Di Ferdinando, D.; Di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Dzhatdoev, T.; Ebert, J.; Ereditato, A.; Fini, R. A.; Fukuda, T.; Galati, G.; Garfagnini, A.; Giacomelli, G.; Göllnitz, C.; Goldberg, J.; Gornushkin, Y.; Grella, G.; Guler, M.; Gustavino, C.; Hagner, C.; Hara, T.; Hollnagel, A.; Hosseini, B.; Ishida, H.; Ishiguro, K.; Jakovcic, K.; Jollet, C.; Kamiscioglu, C.; Kamiscioglu, M.; Kawada, J.; Kim, J. H.; Kim, S. H.; Kitagawa, N.; Klicek, B.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Lauria, A.; Lenkeit, J.; Ljubicic, A.; Longhin, A.; Loverre, P.; Malgin, A.; Malenica, M.; Mandrioli, G.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meregaglia, A.; Mikado, S.; Monacelli, P.; Montesi, M. C.; Morishima, K.; Muciaccia, M. T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Nakatsuka, Y.; Niwa, K.; Ogawa, S.; Okateva, N.; Olshevsky, A.; Omura, T.; Ozaki, K.; Paoloni, A.; Park, B. D.; Park, I. G.; Pasqualini, L.; Pastore, A.; Patrizii, L.; Pessard, H.; Pistillo, C.; Podgrudkov, D.; Polukhina, N.; Pozzato, M.; Pupilli, F.; Roda, M.; Rokujo, H.; Roganova, T.; Rosa, G.; Ryazhskaya, O.; Sato, O.; Schembri, A.; Shakiryanova, I.; Shchedrina, T.; Sheshukov, A.; Shibuya, H.; Shiraishi, T.; Shoziyoev, G.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Spinetti, M.; Stanco, L.; Starkov, N.; Stellacci, S. M.; Stipcevic, M.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Tufanli, S.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J. L.; Wilquet, G.; Wonsak, B.; Yoon, C. S.; Zemskova, S.; Zghiche, A.

    2014-07-01

    The OPERA detector, designed to search for oscillations in the CNGS beam, is located in the underground Gran Sasso laboratory, a privileged location to study TeV-scale cosmic rays. For the analysis here presented, the detector was used to measure the atmospheric muon charge ratio in the TeV region. OPERA collected charge-separated cosmic ray data between 2008 and 2012. More than 3 million atmospheric muon events were detected and reconstructed, among which about 110000 multiple muon bundles. The charge ratio was measured separately for single and for multiple muon events. The analysis exploited the inversion of the magnet polarity which was performed on purpose during the 2012 Run. The combination of the two data sets with opposite magnet polarities allowed minimizing systematic uncertainties and reaching an accurate determination of the muon charge ratio. Data were fitted to obtain relevant parameters on the composition of primary cosmic rays and the associated kaon production in the forward fragmentation region. In the surface energy range 1-20 TeV investigated by OPERA, is well described by a parametric model including only pion and kaon contributions to the muon flux, showing no significant contribution of the prompt component. The energy independence supports the validity of Feynman scaling in the fragmentation region up to TeV/nucleon primary energy.

  20. Flux modulations seen by the muon veto of the GERDA experiment

    NASA Astrophysics Data System (ADS)

    GERDA Collaboration; Agostini, M.; Allardt, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Barros, N.; Baudis, L.; Bauer, C.; Becerici-Schmidt, N.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; di Vacri, A.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Fedorova, O.; Freund, K.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hegai, A.; Heisel, M.; Hemmer, S.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Ioannucci, L.; Janicsk'o Cs'athy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Klimenko, A.; Knapp, M.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Medinaceli, E.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Palioselitis, D.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Riboldi, S.; Ritter, F.; Rumyantseva, N.; Sada, C.; Salathe, M.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schütz, A.-K.; Schulz, O.; Schwingenheuer, B.; Selivanenko, O.; Shevchik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Stepaniuk, M.; Strecker, H.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Walter, M.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wilsenach, H.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2016-11-01

    The GERDA experiment at LNGS of INFN is equipped with an active muon veto. The main part of the system is a water Cherenkov veto with 66 PMTs in the water tank surrounding the GERDA cryostat. The muon flux recorded by this veto shows a seasonal modulation. Two causes have been identified: (i) secondary muons from the CNGS neutrino beam (2.2%) and (ii) a temperature modulation of the atmosphere (1.4%). A mean cosmic muon rate of Iμ0 =(3.477 ± 0 .002stat ± 0 .067sys) ×10-4 /(s · m2) was found in good agreement with other experiments at LNGS. Combining the present result with those from previous experiments at LNGS the effective temperature coefficient αT , Lngs is determined to 0.93 ± 0.03. A fit of the temperature coefficients measured at various underground sites yields a kaon to pion ratio rK/π of 0.10 ± 0.03.

  1. Request for a Test Exposure of OPERA Targets in the NuMI Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kodama, K.; /Aichi U.; Tzanakos, G.

    2004-11-01

    We request to use the Fermilab NuMI neutrino beam in the MINOS Near Detector Hall to produce neutrino interactions in two separate detector arrangements using prototype target bricks designed for the OPERA experiment. OPERA is scheduled to to begin taking data in the CERN Neutrinos to Gran Sasso (CNGS) beam in 2006. The proposed test set up would be located just upstream of the MINOS Near Detector. The data will be used to validate the OPERA analysis scheme and to study backward particle production in neutrino interactions, which is of interest to the OPERA collaboration as well as the neutrinomore » community in general. In addition, we contend that the data taken in this exposure may also be useful to the MINOS collaboration as additional input to the understanding of the initial composition of the neutrino beam. Ideally, this exposure could take place in early to mid-2005, providing timely feedback to both the OPERA and MINOS collaborations.« less

  2. Facilities Performance Indicators Report 2012-13: Tracking Your Facilities Vital Signs

    ERIC Educational Resources Information Center

    APPA: Association of Higher Education Facilities Officers, 2014

    2014-01-01

    This paper features an expanded Web-based "Facilities Performance Indicators (FPI) Report." The purpose of APPA's Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. "The Facilities Performance Indicators Report" is designed for survey…

  3. Facilities Performance Indicators Report 2013-14: Tracking Your Facilities Vital Signs

    ERIC Educational Resources Information Center

    APPA: Association of Higher Education Facilities Officers, 2015

    2015-01-01

    This paper features an expanded Web-based "Facilities Performance Indicators (FPI) Report." The purpose of APPA: Association of Higher Education Facilities Officers (APPA's) Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. "The Facilities Performance…

  4. High-Performance Computing User Facility | Computational Science | NREL

    Science.gov Websites

    User Facility High-Performance Computing User Facility The High-Performance Computing User Facility technologies. Photo of the Peregrine supercomputer The High Performance Computing (HPC) User Facility provides Gyrfalcon Mass Storage System. Access Our HPC User Facility Learn more about these systems and how to access

  5. Facilities Performance Indicators Report, 2008-09

    ERIC Educational Resources Information Center

    Hills, Christina, Ed.

    2010-01-01

    This paper features another expanded Web-based Facilities Performance Indicators Report (FPI). The purpose of APPA's Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. The 2008-09 iteration of the Web-based Facilities Performance Indicators Survey was posted and…

  6. Facility-level outcome performance measures for nursing homes.

    PubMed

    Porell, F; Caro, F G

    1998-12-01

    Risk-adjusted nursing home performance scores were developed for four health outcomes and five quality indicators from resident-level longitudinal case-mix reimbursement data for Medicaid residents of more than 500 nursing homes in Massachusetts. Facility performance was measured by comparing actual resident outcomes with expected outcomes derived from quarterly predictions of resident-level econometric models over a 3-year period (1991-1994). Performance measures were tightly distributed among facilities in the state. The intercorrelations among the nine outcome performance measures were relatively low and not uniformly positive. Performance measures were not highly associated with various structural facility attributes. For most outcomes, longitudinal analyses revealed only modest correlations between a facility's performance score from one time period to the next. Relatively few facilities exhibited consistent superior or inferior performance over time. The findings have implications toward the practical use of facility outcome performance measures for quality assurance and reimbursement purposes in the near future.

  7. Facilities Performance Indicators Report 2011-12: Tracking Your Facilities Vital Signs

    ERIC Educational Resources Information Center

    APPA: Association of Higher Education Facilities Officers, 2013

    2013-01-01

    This paper provides an expanded Web-based "Facilities Performance Indicators (FPI) Report." The purpose of APPA's Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. APPA's Information and Research Committee's goal for this year was to enhance the…

  8. Dialysis Facility Transplant Philosophy and Access to Kidney Transplantation in the Southeast.

    PubMed

    Gander, Jennifer; Browne, Teri; Plantinga, Laura; Pastan, Stephen O; Sauls, Leighann; Krisher, Jenna; Patzer, Rachel E

    2015-01-01

    Little is known about the impact of dialysis facility treatment philosophy on access to transplant. The aim of our study was to determine the relationship between the dialysis facility transplant philosophy and facility-level access to kidney transplant waitlisting. A 25-item questionnaire administered to Southeastern dialysis facilities (n = 509) in 2012 captured the facility transplant philosophy (categorized as 'transplant is our first choice', 'transplant is a great option for some', and 'transplant is a good option, if the patient is interested'). Facility-level waitlisting and facility characteristics were obtained from the 2008-2011 Dialysis Facility Report. Multivariable logistic regression was used to examine the association between the dialysis facility transplant philosophy and facility waitlisting performance (dichotomized using the national median), where low performance was defined as fewer than 21.7% of dialysis patients waitlisted within a facility. Fewer than 25% (n = 124) of dialysis facilities reported 'transplant is our first option'. A total of 131 (31.4%) dialysis facilities in the Southeast were high-performing facilities with respect to waitlisting. Adjusted analysis showed that facilities who reported 'transplant is our first option' were twice (OR 2.0; 95% CI 1.0-3.9) as likely to have high waitlisting performance compared to facilities who reported that 'transplant is a good option, if the patient is interested'. Facilities with staff who had a more positive transplant philosophy were more likely to have better facility waitlisting performance. Future prospective studies are needed to further investigate if improving the kidney transplant philosophy in dialysis facilities improves access to transplantation.

  9. FPI: FM Success through Analytics

    ERIC Educational Resources Information Center

    Hickling, Duane

    2013-01-01

    The APPA Facilities Performance Indicators (FPI) is perhaps one of the most powerful analytical tools that institutional facilities professionals have at their disposal. It is a diagnostic facilities performance management tool that addresses the essential questions that facilities executives must answer to effectively perform their roles. It…

  10. Dialysis Facility Transplant Philosophy and Access to Kidney Transplantation in the Southeast

    PubMed Central

    Gander, Jennifer; Browne, Teri; Plantinga, Laura; Pastan, Stephen O; Sauls, Leighann; Krisher, Jenna; Patzer, Rachel E

    2015-01-01

    Background Little is known about the impact of dialysis facility treatment philosophy on access to transplant. The aim of our study was to determine the relationship between dialysis facility transplant philosophy and facility-level access to kidney transplant waitlisting. Methods A 25-item questionnaire administered to Southeastern dialysis facilities (n=509) in 2012 captured facility transplant philosophy (categorized as “transplant is our first choice,” “transplant is a great option for some,” and “transplant is a good option, if the patient is interested”) .. Facility-level waitlisting and facility characteristics were obtained from the 2008-2011 Dialysis Facility Report. Multivariable logistic regression was used to examinethe association between dialysis facility transplant philosophy and facility waitlisting performance (dichotomized using the national median), where low performance was defined as less than 21.7% of dialysis patients waitlisted within a facility. Results Fewer than 25% (n=124) of dialysis facilities reported “transplant is our first option.” A total of 131 (31.4%) dialysis facilities in the Southeast were high-performing with respect to waitlisting. Adjusted analysis showed that facilities who reported “transplant is our first option” were twice (OR=2.0, 95% CI 1.0, 3.9) as likely to have high waitlisting performance compared to facilities who reported “transplant is a good option, if the patient is interested.” Conclusions Facilities with staff who had a more positive transplant philosophy were more likely to have better facility waitlisting performance. Future prospective studies are needed to further transplantation. PMID:26278585

  11. Facilities Performance Indicators Report, 2004-05. Facilities Core Data Survey

    ERIC Educational Resources Information Center

    Glazner, Steve, Ed.

    2006-01-01

    The purpose of "Facilities Performance Indicators" is to provide a representative set of statistics about facilities in educational institutions. The second iteration of the web-based Facilities Core Data Survey was posted and available to facilities professionals at more than 3,000 institutions in the Fall of 2005. The website offered a printed…

  12. 40 CFR 125.137 - As an owner or operator of a new offshore oil and gas extraction facility, must I perform...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... offshore oil and gas extraction facility, must I perform monitoring? 125.137 Section 125.137 Protection of... operator of a new offshore oil and gas extraction facility, must I perform monitoring? As an owner or operator of a new offshore oil and gas extraction facility, you will be required to perform monitoring to...

  13. 40 CFR 125.137 - As an owner or operator of a new offshore oil and gas extraction facility, must I perform...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... offshore oil and gas extraction facility, must I perform monitoring? 125.137 Section 125.137 Protection of... operator of a new offshore oil and gas extraction facility, must I perform monitoring? As an owner or operator of a new offshore oil and gas extraction facility, you will be required to perform monitoring to...

  14. 40 CFR 125.137 - As an owner or operator of a new offshore oil and gas extraction facility, must I perform...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... offshore oil and gas extraction facility, must I perform monitoring? 125.137 Section 125.137 Protection of... operator of a new offshore oil and gas extraction facility, must I perform monitoring? As an owner or operator of a new offshore oil and gas extraction facility, you will be required to perform monitoring to...

  15. 40 CFR 125.137 - As an owner or operator of a new offshore oil and gas extraction facility, must I perform...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... offshore oil and gas extraction facility, must I perform monitoring? 125.137 Section 125.137 Protection of... operator of a new offshore oil and gas extraction facility, must I perform monitoring? As an owner or operator of a new offshore oil and gas extraction facility, you will be required to perform monitoring to...

  16. Impact of Facilities on Academic Performance of Students with Special Needs in Mainstreamed Public Schools in Southwestern Nigeria

    ERIC Educational Resources Information Center

    Fareo, Dorcas Oluremi; Ojo, Olakunbi Olubukola

    2013-01-01

    Facilities have a great impact on academic performances of students, and inadequate facilities translate to poor performance. The study examined the availability and convenience of the facilities that were provided to students with special educational needs in mainstreamed schools. It ascertained the qualifications of teachers teaching in…

  17. 14 CFR 171.7 - Performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Performance requirements. 171.7 Section 171.7 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES VOR Facilities § 171.7 Performance requirements. (a...

  18. 14 CFR 171.7 - Performance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Performance requirements. 171.7 Section 171.7 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES VOR Facilities § 171.7 Performance requirements. (a...

  19. 14 CFR 171.7 - Performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Performance requirements. 171.7 Section 171.7 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES VOR Facilities § 171.7 Performance requirements. (a...

  20. 14 CFR 171.7 - Performance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Performance requirements. 171.7 Section 171.7 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES VOR Facilities § 171.7 Performance requirements. (a...

  1. Employee organizational commitment and hospital performance.

    PubMed

    Baird, Kevin M; Tung, Amy; Yu, Yanjie

    2017-09-15

    There is widespread evidence of the purported benefits of employee organizational commitment (EOC) and its impact on both individual and organizational performance. This study contributes to this literature by providing a unique insight into this relationship, focusing on the interrelationship between EOC with hospital performance and the role of the provision of adequate facilities in eliciting EOC. The aim of this study was to introduce and empirically examine a new theoretical model in which it is argued that the performance of hospitals with regard to the provision of adequate facilities (medical facilities, support facilities, and staff resources) influences the level of EOC, which in turn influences hospital performance with regard to patient care and operational effectiveness. To examine the interrelationships between the provision of adequate facilities, EOC, and hospital performance, the study utilizes a survey of hospital managers. The findings support the theoretical model, with the provision of support facilities and staff resources positively indirectly associated with both patient care and operational effectiveness through their impact on EOC. The findings highlight the importance of providing adequate facilities and EOC within hospitals and suggest that CEOs and general managers should try to enhance the provision of such resources in an attempt to elicit EOC within their hospitals. The findings suggest that managers should try to enhance their provision of adequate facilities in order to elicit EOC and enhance hospital performance. With regard to medical facilities, they should consider and incorporate the latest technology and up-to-date equipment. They should also provide adequate staff resources, including appropriate numbers of beds, nurses, and doctors, to prevent "fatigue" (West, 2001, p. 41) and provide adequate support facilities.

  2. Metrics for Success: Strategies for Enabling Core Facility Performance and Assessing Outcomes

    PubMed Central

    Hockberger, Philip E.; Meyn, Susan M.; Nicklin, Connie; Tabarini, Diane; Auger, Julie A.

    2016-01-01

    Core Facilities are key elements in the research portfolio of academic and private research institutions. Administrators overseeing core facilities (core administrators) require assessment tools for evaluating the need and effectiveness of these facilities at their institutions. This article discusses ways to promote best practices in core facilities as well as ways to evaluate their performance across 8 of the following categories: general management, research and technical staff, financial management, customer base and satisfaction, resource management, communications, institutional impact, and strategic planning. For each category, we provide lessons learned that we believe contribute to the effective and efficient overall management of core facilities. If done well, we believe that encouraging best practices and evaluating performance in core facilities will demonstrate and reinforce the importance of core facilities in the research and educational mission of institutions. It will also increase job satisfaction of those working in core facilities and improve the likelihood of sustainability of both facilities and personnel. PMID:26848284

  3. Metrics for Success: Strategies for Enabling Core Facility Performance and Assessing Outcomes.

    PubMed

    Turpen, Paula B; Hockberger, Philip E; Meyn, Susan M; Nicklin, Connie; Tabarini, Diane; Auger, Julie A

    2016-04-01

    Core Facilities are key elements in the research portfolio of academic and private research institutions. Administrators overseeing core facilities (core administrators) require assessment tools for evaluating the need and effectiveness of these facilities at their institutions. This article discusses ways to promote best practices in core facilities as well as ways to evaluate their performance across 8 of the following categories: general management, research and technical staff, financial management, customer base and satisfaction, resource management, communications, institutional impact, and strategic planning. For each category, we provide lessons learned that we believe contribute to the effective and efficient overall management of core facilities. If done well, we believe that encouraging best practices and evaluating performance in core facilities will demonstrate and reinforce the importance of core facilities in the research and educational mission of institutions. It will also increase job satisfaction of those working in core facilities and improve the likelihood of sustainability of both facilities and personnel.

  4. 46 CFR 162.050-15 - Designation of facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... This is the mean and standard deviation, respectively, of the differences between the known sample... sample analysis, and the materials necessary to perform the tests; (2) Each facility test rig must be of... facilities. (a) Each request for designation as a facility authorized to perform approval tests must be...

  5. A probability metric for identifying high-performing facilities: an application for pay-for-performance programs.

    PubMed

    Shwartz, Michael; Peköz, Erol A; Burgess, James F; Christiansen, Cindy L; Rosen, Amy K; Berlowitz, Dan

    2014-12-01

    Two approaches are commonly used for identifying high-performing facilities on a performance measure: one, that the facility is in a top quantile (eg, quintile or quartile); and two, that a confidence interval is below (or above) the average of the measure for all facilities. This type of yes/no designation often does not do well in distinguishing high-performing from average-performing facilities. To illustrate an alternative continuous-valued metric for profiling facilities--the probability a facility is in a top quantile--and show the implications of using this metric for profiling and pay-for-performance. We created a composite measure of quality from fiscal year 2007 data based on 28 quality indicators from 112 Veterans Health Administration nursing homes. A Bayesian hierarchical multivariate normal-binomial model was used to estimate shrunken rates of the 28 quality indicators, which were combined into a composite measure using opportunity-based weights. Rates were estimated using Markov Chain Monte Carlo methods as implemented in WinBUGS. The probability metric was calculated from the simulation replications. Our probability metric allowed better discrimination of high performers than the point or interval estimate of the composite score. In a pay-for-performance program, a smaller top quantile (eg, a quintile) resulted in more resources being allocated to the highest performers, whereas a larger top quantile (eg, being above the median) distinguished less among high performers and allocated more resources to average performers. The probability metric has potential but needs to be evaluated by stakeholders in different types of delivery systems.

  6. Impact of Breast Density Legislation on Breast Cancer Risk Assessment and Supplemental Screening: A Survey of 110 Radiology Facilities.

    PubMed

    Nayak, Lina; Miyake, Kanae K; Leung, Jessica W T; Price, Elissa R; Liu, Yueyi I; Joe, Bonnie N; Sickles, Edward A; Thomas, William R; Lipson, Jafi A; Daniel, Bruce L; Hargreaves, Jonathan; Brenner, R James; Bassett, Lawrence W; Ojeda-Fournier, Haydee; Lindfors, Karen K; Feig, Stephen A; Ikeda, Debra M

    2016-09-01

    Breast density notification laws, passed in 19 states as of October 2014, mandate that patients be informed of their breast density. The purpose of this study is to assess the impact of this legislation on radiology practices, including performance of breast cancer risk assessment and supplemental screening studies. A 20-question anonymous web-based survey was emailed to radiologists in the Society of Breast Imaging between August 2013 and March 2014. Statistical analysis was performed using Fisher's exact test. Around 121 radiologists from 110 facilities in 34 USA states and 1 Canadian site responded. About 50% (55/110) of facilities had breast density legislation, 36% of facilities (39/109) performed breast cancer risk assessment (one facility did not respond). Risk assessment was performed as a new task in response to density legislation in 40% (6/15) of facilities in states with notification laws. However, there was no significant difference in performing risk assessment between facilities in states with a law and those without (p < 0.831). In anticipation of breast density legislation, 33% (16/48), 6% (3/48), and 6% (3/48) of facilities in states with laws implemented handheld whole breast ultrasound (WBUS), automated WBUS, and tomosynthesis, respectively. The ratio of facilities offering handheld WBUS was significantly higher in states with a law than in states without (p < 0.001). In response to breast density legislation, more than 33% of facilities are offering supplemental screening with WBUS and tomosynthesis, and many are performing formal risk assessment for determining patient management. © 2016 Wiley Periodicals, Inc.

  7. 49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Tests To Be Performed at the Bus Testing Facility... Part 665—Tests To Be Performed at the Bus Testing Facility The eight tests to be performed on each vehicle are required by SAFETEA-LU and are based in part on tests described in the FTA report “First...

  8. 49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Tests To Be Performed at the Bus Testing Facility... Part 665—Tests To Be Performed at the Bus Testing Facility The eight tests to be performed on each vehicle are required by SAFETEA-LU and are based in part on tests described in the FTA report “First...

  9. Implementation research to improve quality of maternal and newborn health care, Malawi.

    PubMed

    Brenner, Stephan; Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela

    2017-07-01

    To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities' essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants' adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care.

  10. Associations Among Health Care Workplace Safety, Resident Satisfaction, and Quality of Care in Long-Term Care Facilities.

    PubMed

    Boakye-Dankwa, Ernest; Teeple, Erin; Gore, Rebecca; Punnett, Laura

    2017-11-01

    We performed an integrated cross-sectional analysis of relationships between long-term care work environments, employee and resident satisfaction, and quality of patient care. Facility-level data came from a network of 203 skilled nursing facilities in 13 states in the eastern United States owned or managed by one company. K-means cluster analysis was applied to investigate clustered associations between safe resident handling program (SRHP) performance, resident care outcomes, employee satisfaction, rates of workers' compensation claims, and resident satisfaction. Facilities in the better-performing cluster were found to have better patient care outcomes and resident satisfaction; lower rates of workers compensation claims; better SRHP performance; higher employee retention; and greater worker job satisfaction and engagement. The observed clustered relationships support the utility of integrated performance assessment in long-term care facilities.

  11. Assessing the security vulnerabilities of correctional facilities

    NASA Astrophysics Data System (ADS)

    Spencer, Debra D.; Morrison, G. Steve

    1998-12-01

    The National Institute of Justice has tasked their satellite facility at Sandia National Laboratories and their Southeast Regional Technology Center in Charleston, South Carolina to devise new procedures and tools for helping correctional facilities to assess their security vulnerabilities. Thus, a team is visiting selected correctional facilities and performing vulnerability assessments. A vulnerability assessment helps identify the easiest paths for inmate escape, for introduction of contraband such as drugs or weapons, for unexpected intrusion from outside of the facility, and for the perpetration of violent acts on other inmates and correctional employees. In addition, the vulnerability assessment helps to quantify the security risks for the facility. From these assessments will come better procedures for performing vulnerability assessments in general at other correctional facilities, as well as the development of tools to assist with the performance of such vulnerability assessments.

  12. Realistic Development and Testing of Fission System at a Non-Nuclear Testing Facility

    NASA Technical Reports Server (NTRS)

    Godfroy, Tom; VanDyke, Melissa; Dickens, Ricky; Pedersen, Kevin; Lenard, Roger; Houts, Mike

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on a module has been performed at the Marshall Space Flight Center in the Propellant Energy Source Testbed (PEST). This paper discusses the experimental facilities and equipment used for performing resistance heated tests. Recommendations are made for improving non-nuclear test facilities and equipment for simulated testing of nuclear systems.

  13. Realistic development and testing of fission systems at a non-nuclear testing facility

    NASA Astrophysics Data System (ADS)

    Godfroy, Tom; van Dyke, Melissa; Dickens, Ricky; Pedersen, Kevin; Lenard, Roger; Houts, Mike

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on a module has been performed at the Marshall Space Flight Center in the Propellant Energy Source Testbed (PEST). This paper discusses the experimental facilities and equipment used for performing resistance heated tests. Recommendations are made for improving non-nuclear test facilities and equipment for simulated testing of nuclear systems. .

  14. School Types, Facilities and Academic Performance of Students in Senior Secondary Schools in Ondo State, Nigeria

    ERIC Educational Resources Information Center

    Alimi, Olatunji Sabitu; Ehinola, Gabriel Babatunde; Alabi, Festus Oluwole

    2012-01-01

    The study investigated the influence of school types and facilities on students' academic performance in Ondo State. It was designed to find out whether facilities and students' academic performance are related in private and public secondary schools respectively. Descriptive survey design was used. Proportionate random sampling technique was used…

  15. Improving performance of Zambia Defence Force antiretroviral therapy providers: evaluation of a standards-based approach

    PubMed Central

    Kim, Young Mi; Banda, Joseph; Kanjipite, Webby; Sarkar, Supriya; Bazant, Eva; Hiner, Cyndi; Tholandi, Maya; Reinhardt, Stephanie; Njobvu, Panganani Dalisani; Kols, Adrienne; Benavides, Bruno

    2013-01-01

    ABSTRACT Background: The Zambia Defence Force (ZDF) has applied the Standards-Based Management and Recognition (SBM-R®) approach, which uses detailed performance standards, at some health facilities to improve HIV-related services offered to military personnel and surrounding civilian communities. This study examines the effectiveness of the SBM-R approach in improving facility readiness and provider performance at ZDF facilities. Methods: We collected data on facility readiness and provider performance before and after the 2010–2012 intervention at 4 intervention sites selected for their relatively poor performance and 4 comparison sites. Assessors observed whether each facility met 16 readiness standards and whether providers met 9 performance standards during consultations with 354 returning antiretroviral therapy (ART) clients. We then calculated the percentages of criteria achieved for each readiness and performance standard and conducted bivariate and multivariate analyses of provider performance data. Results: Facilities' ART readiness scores exceeded 80% before the intervention at both intervention and comparison sites. At endline, scores improved on 4 facility readiness standards in the intervention group but on only 1 standard in the comparison group. Multivariate analysis found that the overall provider performance score increased significantly in the intervention group (from 58% to 84%; P<.01) but not in the comparison group (from 62% to 70%). The before-and-after improvement in scores was significantly greater among intervention sites than among comparison sites for 2 standards—initial assessment of the client's condition and nutrition counseling. Conclusion: The standards-based approach, which involved intensive and mutually reinforcing intervention activities, showed modest improvements in some aspects of providers' performance during ART consultations. Further research is needed to determine whether improvements in provider performance affect client outcomes such as adherence to ART. PMID:25276534

  16. Pavement testing facility : effects of tire pressure on flexible pavement response performance

    DOT National Transportation Integrated Search

    1989-08-01

    The effects of tire pressure on flexible pavement response and performance were evaluated using data from the first phase of research at the Federal Highway Administration's Pavement Testing Facility. The Accelerated Loading Facility testing machine ...

  17. Modelling Pedestrian Travel Time and the Design of Facilities: A Queuing Approach

    PubMed Central

    Rahman, Khalidur; Abdul Ghani, Noraida; Abdulbasah Kamil, Anton; Mustafa, Adli; Kabir Chowdhury, Md. Ahmed

    2013-01-01

    Pedestrian movements are the consequence of several complex and stochastic facts. The modelling of pedestrian movements and the ability to predict the travel time are useful for evaluating the performance of a pedestrian facility. However, only a few studies can be found that incorporate the design of the facility, local pedestrian body dimensions, the delay experienced by the pedestrians, and level of service to the pedestrian movements. In this paper, a queuing based analytical model is developed as a function of relevant determinants and functional factors to predict the travel time on pedestrian facilities. The model can be used to assess the overall serving rate or performance of a facility layout and correlate it to the level of service that is possible to provide the pedestrians. It has also the ability to provide a clear suggestion on the designing and sizing of pedestrian facilities. The model is empirically validated and is found to be a robust tool to understand how well a particular walking facility makes possible comfort and convenient pedestrian movements. The sensitivity analysis is also performed to see the impact of some crucial parameters of the developed model on the performance of pedestrian facilities. PMID:23691055

  18. Impact of facility size and profit status on intermediate outcomes in chronic dialysis patients.

    PubMed

    Frankenfield, D L; Sugarman, J R; Presley, R J; Helgerson, S D; Rocco, M V

    2000-08-01

    Little information is available regarding the influence of dialysis facility size or profit status on intermediate outcomes in chronic dialysis patients. We have combined data from the Health Care Financing Administration (HCFA) Core Indicators Project; the end-stage renal disease (ESRD) facility survey; and the HCFA On-Line Survey, Certification, and Reporting System to analyze trends in this area. For hemodialysis patients, larger facilities were more likely than smaller facilities to perform dialysis on patients who were younger than 65 years of age, black, or undergoing dialysis 2 years or more (P < 0.001). Nonprofit facilities were more likely to perform dialysis on patients with diabetes mellitus as a cause of ESRD and less likely to perform dialysis on patients with hypertension as a cause of ESRD compared with for-profit units (P < 0.05). By multivariate analysis, larger facility size was modestly associated with a greater Kt/V value and urea reduction ratio, but not with hematocrit or serum albumin values. Facility profit status was not associated with these intermediate outcomes. For peritoneal dialysis patients, there were no significant differences in patient demographics based on facility size. More patients in nonprofit units had been undergoing dialysis 2 or more years than patients in for-profit units (P < 0.05). By univariate analysis, patients in larger facilities were more likely to have an adequacy measure performed than patients from smaller facilities (P < 0.05). There were few substantial differences in intermediate outcomes in chronic dialysis patients based on facility size or profit status.

  19. Money for Research, Not for Energy Bills: Finding Energy and Cost Savings in High Performance Computer Facility Designs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drewmark Communications; Sartor, Dale; Wilson, Mark

    2010-07-01

    High-performance computing facilities in the United States consume an enormous amount of electricity, cutting into research budgets and challenging public- and private-sector efforts to reduce energy consumption and meet environmental goals. However, these facilities can greatly reduce their energy demand through energy-efficient design of the facility itself. Using a case study of a facility under design, this article discusses strategies and technologies that can be used to help achieve energy reductions.

  20. 40 CFR 60.190 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Aluminum Reduction Plants § 60.190 Applicability and designation of affected facility. (a) The affected facilities in primary aluminum reduction plants to which this subpart applies are...

  1. Preliminary hazards analysis -- vitrification process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coordes, D.; Ruggieri, M.; Russell, J.

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility`s constructionmore » and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment.« less

  2. Emergency, anaesthetic and essential surgical capacity in the Gambia

    PubMed Central

    Shivute, Nestor; Bickler, Stephen; Cole-Ceesay, Ramou; Jargo, Bakary; Abdullah, Fizan; Cherian, Meena

    2011-01-01

    Abstract Objective To assess the resources for essential and emergency surgical care in the Gambia. Methods The World Health Organization’s Tool for Situation Analysis to Assess Emergency and Essential Surgical Care was distributed to health-care managers in facilities throughout the country. The survey was completed by 65 health facilities – one tertiary referral hospital, 7 district/general hospitals, 46 health centres and 11 private health facilities – and included 110 questions divided into four sections: (i) infrastructure, type of facility, population served and material resources; (ii) human resources; (iii) management of emergency and other surgical interventions; (iv) emergency equipment and supplies for resuscitation. Questionnaire data were complemented by interviews with health facility staff, Ministry of Health officials and representatives of nongovernmental organizations. Findings Important deficits were identified in infrastructure, human resources, availability of essential supplies and ability to perform trauma, obstetric and general surgical procedures. Of the 18 facilities expected to perform surgical procedures, 50.0% had interruptions in water supply and 55.6% in electricity. Only 38.9% of facilities had a surgeon and only 16.7% had a physician anaesthetist. All facilities had limited ability to perform basic trauma and general surgical procedures. Of public facilities, 54.5% could not perform laparotomy and 58.3% could not repair a hernia. Only 25.0% of them could manage an open fracture and 41.7% could perform an emergency procedure for an obstructed airway. Conclusion The present survey of health-care facilities in the Gambia suggests that major gaps exist in the physical and human resources needed to carry out basic life-saving surgical interventions. PMID:21836755

  3. 76 FR 57980 - Senior Executive Service Performance Review Board

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-19

    ... DEFENSE NUCLEAR FACILITIES SAFETY BOARD Senior Executive Service Performance Review Board AGENCY... the Defense Nuclear Facilities Safety Board (DNFSB) Senior Executive Service (SES) Performance Review... summary rating of the senior executive's performance, the executive's response, and the higher level...

  4. 77 FR 54570 - Senior Executive Service Performance Review Board

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-05

    ... DEFENSE NUCLEAR FACILITIES SAFETY BOARD Senior Executive Service Performance Review Board AGENCY... the Defense Nuclear Facilities Safety Board (DNFSB) Senior Executive Service (SES) Performance Review.... The PRB shall review and evaluate the initial summary rating of the senior executive's performance...

  5. Targeting nursing homes under the Quality Improvement Organization program's 9th statement of work.

    PubMed

    Stevenson, David G; Mor, Vincent

    2009-09-01

    In the Quality Improvement Organization (QIO) program's latest Statement of Work, the Centers for Medicare and Medicaid Services (CMS) is targeting its nursing home activities toward facilities that perform poorly on two quality measures-pressure ulcers and restraint use. The designation of target facilities is a shift in strategy for CMS and a direct response to criticism that QIO program resources were not being targeted effectively to facilities or clinical areas that most needed improvement. Using administrative data, this article analyzes implications of using narrowly defined criteria to identify facilities that need improvement, particularly in light of considerable evidence showing that nursing home quality is multidimensional and may change over time. The analyses show that one in four facilities is targeted for improvement nationally but that approximately half of some states' facilities are targeted while other states have almost none targeted. The analyses also convey deeper limitations to using threshold values on individual measures to identify poorly performing homes. Target facilities can be among the top performers on a range of other quality measures, and their performance on targeted measures themselves may change over time. The implication of these features is that a very different group of facilities would have been chosen had the QIO program targeted other measures or examined performance at a different point in time. Ultimately, CMS has chosen a blunt instrument to identify poorly performing nursing homes, and supplemental strategies-such as soliciting input from state survey agencies and more closely aligning quality improvement and quality assurance efforts-should be considered to address potential limitations.

  6. Gas-Grain Simulation Facility (GGSF). Volume 1: Stage 1 facility definition studies

    NASA Technical Reports Server (NTRS)

    Gat, Nahum

    1993-01-01

    The Gas-Grain Simulation Facility (GGSF) is a facility-type payload to be included in the Space Station Freedom (SSF). The GGSF is a multidisciplinary facility that will accommodate several classes of experiments, including exobiology, planetary science, atmospheric science, and astrophysics. The physical mechanisms envisioned to be investigated include crystal growth, aggregation, nucleation, coagulation, condensation, collisions, fractal growth, cycles of freezing and evaporation, scavenging, longevity of bacteria, and more. TRW performed a Phase A study that included analyses of the science and technical (S&T) requirements, the development of facility functional requirements, and a conceptual design of the facility. The work that was performed under Stage 1 of the Phase A study and the results to date are summarized. In this stage, facility definition studies were conducted in sufficient detail to establish the technical feasibility of the candidate strawman experiments. The studies identified technical difficulties, identified required facility subsystems, surveyed existing technology studies and established preliminary facility weight, volume, power consumption, data systems, interface definition, and crew time requirements. The results of this study served as the basis for Stage 2 of the Phase A study in which a conceptual design and a reference design were performed. The results also served as a basis for a related study for a Gas-Grain Simulation Experiment Module (GGSEM), which is an apparatus intended to perform a subset of the GGSF experiments on board a low-Earth-orbiting platform.

  7. 40 CFR 60.170 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Zinc Smelters § 60.170 Applicability and designation of affected facility. (a) The...: roaster and sintering machine. (b) Any facility under paragraph (a) of this section that commences...

  8. First regulatory inspections measuring adherence to Good Pharmacy Practices in the public sector in Uganda: a cross-sectional comparison of performance between supervised and unsupervised facilities.

    PubMed

    Trap, Birna; Kikule, Kate; Vialle-Valentin, Catherine; Musoke, Richard; Lajul, Grace Otto; Hoppenworth, Kim; Konradsen, Dorthe

    2016-01-01

    Since its inception, the Uganda National Drug Authority (NDA) has regularly inspected private sector pharmacies to monitor adherence to Good Pharmacy Practices (GPP). This study reports findings from the first public facility inspections following an intervention (SPARS: Supervision, Performance Assessment, and Recognition Strategy) to build GPP and medicines management capacity in the public sector. The study includes 455 public facilities: 417 facilities were inspected after at least four SPARS visits by trained managerial district staff (SPARS group), 38 before any exposure to SPARS. NDA inspectors measured 10 critical, 20 major, and 37 minor GPP indicators in every facility and only accredited facilities that passed all 10 critical and failed no more than 7 major indicators. Lack of compliance for a given indicator was defined as less than 75 % facilities passing that indicator. We assessed factors associated with certification using logistic regression analysis and compared number of failed indicators between the SPARS and comparative groups using two sample t-tests with equal or unequal variance. 57.4 % of inspected facilities obtained GPP certification: 57.1 % in the SPARS and 60.5 % in the comparative group (Adj. OR = 0.91, 95 % CI 0.45-1.85, p = 0.802). Overall, facilities failed an average of 10 indicators. SPARS facilities performed better than comparative facilities (9 (SD 6.1) vs. 13 (SD 7.7) failed indicators respectively; p = 0.017), and SPARS supported facilities scored better on indicators covered by SPARS. For all indicators but one minor, performance in the SPARS group was equal to or significantly better than in unsupervised facilities. Within the SPARS (intervention) group, certified facilities had < 75 % compliance on 7 indicators (all minor), and uncertified facilities on 19 (4 critical, 2 major, and 13 minor) indicators. Half of the Ugandan population obtains medicines from the public sector. Yet, we found only 3/5 of inspected public health facilities meet GPP standards. SPARS facilities tended to perform better than unsupervised facilities, substantiating the value of supporting supervision interventions in GPP areas that need strengthening. None compliant indicators can be improved through practices and behavioral changes; some require infrastructure investments. We conclude that regular NDA inspections of public sector pharmacies in conjunction with interventions to improve GPP adherence can revolutionize patient care in Uganda.

  9. Factors associated with malaria microscopy diagnostic performance following a pilot quality-assurance programme in health facilities in malaria low-transmission areas of Kenya, 2014.

    PubMed

    Odhiambo, Fredrick; Buff, Ann M; Moranga, Collins; Moseti, Caroline M; Wesongah, Jesca Okwara; Lowther, Sara A; Arvelo, Wences; Galgalo, Tura; Achia, Thomas O; Roka, Zeinab G; Boru, Waqo; Chepkurui, Lily; Ogutu, Bernhards; Wanja, Elizabeth

    2017-09-13

    Malaria accounts for ~21% of outpatient visits annually in Kenya; prompt and accurate malaria diagnosis is critical to ensure proper treatment. In 2013, formal malaria microscopy refresher training for microscopists and a pilot quality-assurance (QA) programme for malaria diagnostics were independently implemented to improve malaria microscopy diagnosis in malaria low-transmission areas of Kenya. A study was conducted to identify factors associated with malaria microscopy performance in the same areas. From March to April 2014, a cross-sectional survey was conducted in 42 public health facilities; 21 were QA-pilot facilities. In each facility, 18 malaria thick blood slides archived during January-February 2014 were selected by simple random sampling. Each malaria slide was re-examined by two expert microscopists masked to health-facility results. Expert results were used as the reference for microscopy performance measures. Logistic regression with specific random effects modelling was performed to identify factors associated with accurate malaria microscopy diagnosis. Of 756 malaria slides collected, 204 (27%) were read as positive by health-facility microscopists and 103 (14%) as positive by experts. Overall, 93% of slide results from QA-pilot facilities were concordant with expert reference compared to 77% in non-QA pilot facilities (p < 0.001). Recently trained microscopists in QA-pilot facilities performed better on microscopy performance measures with 97% sensitivity and 100% specificity compared to those in non-QA pilot facilities (69% sensitivity; 93% specificity; p < 0.01). The overall inter-reader agreement between QA-pilot facilities and experts was κ = 0.80 (95% CI 0.74-0.88) compared to κ = 0.35 (95% CI 0.24-0.46) between non-QA pilot facilities and experts (p < 0.001). In adjusted multivariable logistic regression analysis, recent microscopy refresher training (prevalence ratio [PR] = 13.8; 95% CI 4.6-41.4), ≥5 years of work experience (PR = 3.8; 95% CI 1.5-9.9), and pilot QA programme participation (PR = 4.3; 95% CI 1.0-11.0) were significantly associated with accurate malaria diagnosis. Microscopists who had recently completed refresher training and worked in a QA-pilot facility performed the best overall. The QA programme and formal microscopy refresher training should be systematically implemented together to improve parasitological diagnosis of malaria by microscopy in Kenya.

  10. High-Performance Computing Data Center | Energy Systems Integration

    Science.gov Websites

    Facility | NREL High-Performance Computing Data Center High-Performance Computing Data Center The Energy Systems Integration Facility's High-Performance Computing Data Center is home to Peregrine -the largest high-performance computing system in the world exclusively dedicated to advancing

  11. 75 FR 56999 - Senior Executive Service Performance Review Board

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-17

    ... DEFENSE NUCLEAR FACILITIES SAFETY BOARD Senior Executive Service Performance Review Board AGENCY... the Defense Nuclear Facilities Safety Board (DNFSB) Senior Executive Service (SES) Performance Review... performance review boards. The PRB shall review and evaluate the initial summary rating of the senior...

  12. 40 CFR 60.91 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.91... Act and in subpart A of this part. (a) Hot mix asphalt facility means any facility, as described in § 60.90, used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt...

  13. 40 CFR 60.91 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.91... Act and in subpart A of this part. (a) Hot mix asphalt facility means any facility, as described in § 60.90, used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt...

  14. 40 CFR 60.91 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.91... Act and in subpart A of this part. (a) Hot mix asphalt facility means any facility, as described in § 60.90, used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt...

  15. 40 CFR 60.91 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.91... Act and in subpart A of this part. (a) Hot mix asphalt facility means any facility, as described in § 60.90, used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt...

  16. 40 CFR 60.91 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.91... Act and in subpart A of this part. (a) Hot mix asphalt facility means any facility, as described in § 60.90, used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt...

  17. The drivers of facility-based immunization performance and costs. An application to Moldova.

    PubMed

    Maceira, Daniel; Goguadze, Ketevan; Gotsadze, George

    2015-05-07

    This paper identifies factors that affect the cost and performance of the routine immunization program in Moldova through an analysis of facility-based data collected as part of a multi-country costing and financing study of routine immunization (EPIC). A nationally representative sample of health care facilities (50) was selected through multi-stage, stratified random sampling. Data on inputs, unit prices and facility outputs were collected during October 3rd 2012-January 14th 2013 using a pre-tested structured questionnaire. Ordinary least square (OLS) regression analysis was performed to determine factors affecting facility outputs (number of doses administered and fully immunized children) and explaining variation in total facility costs. The study found that the number of working hours, vaccine wastage rates, and whether or not a doctor worked at a facility (among other factors) were positively and significantly associated with output levels. In addition, the level of output, price of inputs and share of the population with university education were significantly associated with higher facility costs. A 1% increase in fully immunized child would increase total cost by 0.7%. Few costing studies of primary health care services in developing countries evaluate the drivers of performance and cost. This exercise attempted to fill this knowledge gap and helped to identify organizational and managerial factors at a primary care district and national level that could be addressed by improved program management aimed at improved performance. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Implementation research to improve quality of maternal and newborn health care, Malawi

    PubMed Central

    Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela

    2017-01-01

    Abstract Objective To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. Methods We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities’ essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. Findings We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants’ adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Conclusion Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care. PMID:28670014

  19. A longitudinal analysis of nursing home outcomes.

    PubMed

    Porell, F; Caro, F G; Silva, A; Monane, M

    1998-10-01

    To investigate resident and facility attributes associated with long-term care health outcomes in nursing homes. Quarterly Management Minutes Questionnaire (MMQ) survey data for Medicaid case-mix reimbursement of nursing homes in Massachusetts from 1991 to 1994, for specification of outcomes and resident attributes. Facility attributes are specified from cost report data. Multivariate logistic and "state-dependence" regression models are estimated for survival, ADL functional status, incontinence status, and mental status outcomes from longitudinal residence histories of Medicaid residents spanning 3 to 36 months in length. Outcomes are specified to be a function of resident demographic and diagnostic attributes and facility-level operating and nurse staffing attributes. The estimated parameters for resident demographic and diagnostic attributes showed a great deal of construct validity with respect to clinical expectations regarding risk factors for adverse outcomes. Few facility attributes were associated with outcomes generally, and none was significantly associated with all four outcomes. The absence of uniform associations between facility attributes and the various long-term care health outcomes studied suggests that strong facility performance on one health outcome may coexist with much weaker performance on other outcomes. This has implications for the aggregation of individual facility performance measures on multiple outcomes and the development of overall outcome performance measures.

  20. 14 CFR 171.205 - Minimum requirements for approval.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES VHF Marker Beacons § 171.205 Minimum... marker beacon facility under this subpart: (1) The facility's performances, as determined by air and...

  1. Multiple ART Programs Create a Dilemma for Providers to Monitor ARV Adherence in Uganda.

    PubMed

    Obua, Celestino; Gusdal, Annelie; Waako, Paul; Chalker, John C; Tomson, Goran; Wahlström, Rolf; Team, The Inrud-Iaa

    2011-01-01

    Increased availability and accessibility of antiretroviral therapy (ART) has improved the length and quality of life amongst people living with HIV/AIDS. This has changed the landscape for care from episodic to long-term care that requires more monitoring of adherence. This has led to increased demand on human resources, a major problem for most ART programs. This paper presents experiences and perspectives of providers in ART facilities, exploring the organizational factors affecting their capacity to monitor adherence to ARVs. From an earlier survey to test adherence indicators and rank facilities as good, medium or poor adherence performances, six facilities were randomly selected, two from each rank. Observations on facility set-up, provider-patient interactions and key informant interviews were carried out. The strengths, weaknesses, opportunities and threats identified by health workers as facilitators or barriers to their capacity to monitor adherence to ARVs were explored during group discussions. Findings show that the performance levels of the facilities were characterized by four different organizational ART programs operating in Uganda, with apparent lack of integration and coordination at the facilities. Of the six facilities studied, the two high adherence performing facilities were Non-Governmental Organization (NGO) programs, while facilities with dual organizational programs (Governmental/NGO) performed poorly. Working conditions, record keeping and the duality of programs underscored the providers' capacity to monitor adherence. Overall 70% of the observed provider-patient interactions were conducted in environments that ensured privacy of the patient. The mean performance for record keeping was 79% and 50% in the high and low performing facilities respectively. Providers often found it difficult to monitor adherence due to the conflicting demands from the different organizational ART programs. Organizational duality at facilities is a major factor in poor adherence monitoring. The different ART programs in Uganda need to be coordinated and integrated into a single well resourced program to improve ART services and adherence monitoring. The focus on long-term care of patients on ART requires that the limitations to providers' capacity for monitoring adherence become central during the planning and implementation of ART programs.

  2. 14 CFR 171.207 - Performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Performance requirements. 171.207 Section...) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES VHF Marker Beacons § 171.207 Performance requirements. (a) VHF Marker Beacons must meet the performance requirements set forth in the “International...

  3. 14 CFR 171.207 - Performance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Performance requirements. 171.207 Section...) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES VHF Marker Beacons § 171.207 Performance requirements. (a) VHF Marker Beacons must meet the performance requirements set forth in the “International...

  4. 14 CFR 171.207 - Performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Performance requirements. 171.207 Section...) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES VHF Marker Beacons § 171.207 Performance requirements. (a) VHF Marker Beacons must meet the performance requirements set forth in the “International...

  5. Both Patient and Facility Contribute to Achieving the Centers for Medicare and Medicaid Services' Pay-for-Performance Target for Dialysis Adequacy

    PubMed Central

    Tighiouart, Hocine; Meyer, Klemens B.; Miskulin, Dana C.

    2011-01-01

    The Centers for Medicare and Medicaid Services (CMS) designated the achieved urea reduction ratio (URR) as a pay-for-performance measure, but to what extent this measure reflects patient characteristics and adherence instead of its intent to reflect facility performance is unknown. Here, we quantified the contributions of patient case-mix and adherence to the variability in achieving URR targets across dialysis facilities. We found that 92% of 10,069 hemodialysis patients treated at 173 facilities during the last quarter of 2004 achieved the target URR ≥65%. Mixed-effect models with random intercept for dialysis facility revealed a significant facility effect: 11.5% of the variation in achievement of target URR was attributable to the facility level. Adjusting for patient case-mix reduced the proportion of variation attributable to the facility level to 6.7%. Patient gender, body surface area, dialysis access, and adherence with treatment strongly associated with achievement of the URR target. We could not identify specific facility characteristics that explained the remaining variation between facilities. These data suggest that if adherence is not a modifiable patient characteristic, providers could be unfairly penalized for caring for these patients under current CMS policy. These penalties may have unintended consequences. PMID:22025629

  6. Facilities | Integrated Energy Solutions | NREL

    Science.gov Websites

    strategies needed to optimize our entire energy system. A photo of the high-performance computer at NREL . High-Performance Computing Data Center High-performance computing facilities at NREL provide high-speed

  7. Composite analysis E-area vaults and saltstone disposal facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, J.R.

    1997-09-01

    This report documents the Composite Analysis (CA) performed on the two active Savannah River Site (SRS) low-level radioactive waste (LLW) disposal facilities. The facilities are the Z-Area Saltstone Disposal Facility and the E-Area Vaults (EAV) Disposal Facility. The analysis calculated potential releases to the environment from all sources of residual radioactive material expected to remain in the General Separations Area (GSA). The GSA is the central part of SRS and contains all of the waste disposal facilities, chemical separations facilities and associated high-level waste storage facilities as well as numerous other sources of radioactive material. The analysis considered 114 potentialmore » sources of radioactive material containing 115 radionuclides. The results of the CA clearly indicate that continued disposal of low-level waste in the saltstone and EAV facilities, consistent with their respective radiological performance assessments, will have no adverse impact on future members of the public.« less

  8. The National Ignition Facility: Transition to a User Facility

    NASA Astrophysics Data System (ADS)

    Moses, E. I.; Atherton, J.; Lagin, L.; Larson, D.; Keane, C.; MacGowan, B.; Patterson, R.; Spaeth, M.; Van Wonterghem, B.; Wegner, P.; Kauffman, R.

    2016-03-01

    The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) has been operational since March 2009 and has been transitioning to a user facility supporting ignition science, high energy density science (HEDS), national security applications, and fundamental science. The facility has achieved its design goal of 1.8 MJ and 500 TW of 3ω light on target, and has performed target experiments with 1.9 MJ at peak powers of 410 TW. The facility is on track to perform over 200 target shots this year in support of all of its user communities. The facility has nearly 60 diagnostic systems operational and has shown flexibility in laser pulse shape and performance to meet the requirements of its multiple users. Progress continues on its goal of demonstrating thermonuclear burn in the laboratory. It has performed over 40 indirect-drive experiments with cryogenic-layered capsules. New platforms are being developed for HEDS and fundamental science. Equation-of-state and material strength experiments have been done on a number of materials with pressures of over 50 MBars obtained in diamond, conditions never previously encountered in the laboratory and similar to those found in planetary interiors. Experiments are also in progress investigating radiation transport, hydrodynamic instabilities, and direct drive implosions. NIF continues to develop as an experimental facility. Advanced Radiographic Capability (ARC) is now being installed on NIF for producing high-energy radiographs of the imploded cores of ignition targets and for short pulse laser-plasma interaction experiments. One NIF beam is planned for conversion to two picosecond beams in 2014. Other new diagnostics such as x-ray Thomson scattering, low energy neutron spectrometer, and multi-layer reflecting x-ray optics are also planned. Incremental improvements in laser performance such as improved optics damage performance, beam balance, and back reflection control are being pursued.

  9. 40 CFR 270.42 - Permit modification at the request of the permittee.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... storage in tanks or containers, or in containment buildings in accordance with 40 CFR part 268; (C) To...) Performance Track member facilities. The following procedures apply to Performance Track member facilities... Track member facilities must have complied with the requirements of § 264.15(b)(5) in order to request a...

  10. 40 CFR 270.42 - Permit modification at the request of the permittee.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... storage in tanks or containers, or in containment buildings in accordance with 40 CFR part 268; (C) To...) Performance Track member facilities. The following procedures apply to Performance Track member facilities... Track member facilities must have complied with the requirements of § 264.15(b)(5) in order to request a...

  11. 40 CFR 270.42 - Permit modification at the request of the permittee.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... storage in tanks or containers, or in containment buildings in accordance with 40 CFR part 268; (C) To...) Performance Track member facilities. The following procedures apply to Performance Track member facilities... Track member facilities must have complied with the requirements of § 264.15(b)(5) in order to request a...

  12. 40 CFR 270.42 - Permit modification at the request of the permittee.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... storage in tanks or containers, or in containment buildings in accordance with 40 CFR part 268; (C) To...) Performance Track member facilities. The following procedures apply to Performance Track member facilities... Track member facilities must have complied with the requirements of § 264.15(b)(5) in order to request a...

  13. Radiography Capabilities for Matter-Radiation Interactions in Extremes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walstrom, Peter Lowell; Garnett, Robert William; Chapman, Catherine A. B

    The Matter-Radiation Interactions in Extremes (MaRIE) experimental facility will be used to discover and design the advanced materials needed to meet 21st century national security and energy security challenges. This new facility will provide the new tools scientists need to develop next-generation materials that will perform predictably and on-demand for currently unattainable lifetimes in extreme environments. The MaRIE facility is based on upgrades to the existing LANSCE 800-MeV proton linac and a new 12-GeV electron linac and associated X-ray FEL to provide simultaneous multiple probe beams, and new experimental areas. In addition to the high-energy photon probe beam, both electronmore » and proton radiography capabilities will be available at the MaRIE facility. Recently, detailed radiography system studies have been performed to develop conceptual layouts of high-magnification electron and proton radiography systems that can meet the experimental requirements for the expected first experiments to be performed at the facility. A description of the radiography systems, their performance requirements, and a proposed facility layout are presented.« less

  14. [Anesthesia practice in Catalan hospitals and other health care facilities].

    PubMed

    Villalonga, Antonio; Sabaté, Sergi; Campos, Juan Manuel; Fornaguera, Joan; Hernández, Carmen; Sistac, José María

    2006-05-24

    The aim of this arm of the ANESCAT study was to characterize anesthesia practice in the various types of health care facilities of Catalonia, Spain, in 2003. We analyzed data from the survey according to a) source of a facility's funding: public hospitals financed by the Catalan Public Health Authority (ICS), the network of subsidized hospitals for public use (XHUP), or private hospitals; b) size: facilities without hospital beds, hospitals with fewer than 250 beds, those with 251 to 500, and those with over 500; and c) training accreditation status: whether or not a facility gave medical resident training. A total of 131 facilities participated (11 under the ICS, 47 from the XHUP, and 73 private hospitals). Twenty-six clinics had no hospital beds, 78 facilities had fewer than 250, 21 had 251 to 500, and 6 had more than 500. Seventeen hospitals trained medical residents. XHUP hospitals performed 44.3% of all anesthetic procedures, private hospitals 36.7%, and ICS facilities 18.5%. Five percent of procedures were performed in clinics without beds, 42.9% in facilities with fewer than 250 beds, 35% in hospitals with 251 to 500, and 17.1% in hospitals with over 500. Anesthetists in teaching hospitals performed 35.5% of all procedures. The mean age of patients was lower in private hospitals, facilities with fewer than 250 beds, and hospitals that did not train medical residents. The physical status of patients was worse in ICS hospitals, in facilities with over 500 beds, and in teaching hospitals. It was noteworthy that 25% of anesthetic procedures were performed on an emergency basis in XHUP and ICS hospitals, in facilities with more than 250 beds, and in teaching hospitals. Anesthesia for outpatient procedures accounted for 40% of the total in private hospitals and 31% of the practice in ICS and XHUP hospitals. The duration of anesthesia and postanesthetic recovery was longer in ICS hospitals, in facilities with over 500 beds, and in those with medical resident training programs. The numbers of postoperative admissions to critical care units and of specialized analgesic techniques performed were higher in ICS hospitals, in facilities with over 500 beds, and in teaching hospitals. The complexity of both anesthesia and surgical practice and the severity of patient condition increased with hospital size and public funding status.

  15. A User's Guide for the Spacecraft Fire Safety Facility

    NASA Technical Reports Server (NTRS)

    Goldmeer, Jeffrey S.

    2000-01-01

    The Spacecraft Fire Safety Facility (SFSF) is a test facility that can be flown on NASA's reduced gravity aircraft to perform various types of combustion experiments under a variety of experimental conditions. To date, this facility has flown numerous times on the aircraft and has been used to perform experiments ranging from an examination of the effects transient depressurization on combustion, to ignition and flame spread. A list of pubfications/presentations based on experiments performed in the SFSF is included in the reference section. This facility consists of five main subsystems: combustion chamber, sample holders, gas flow system, imaging system, and the data acquisition/control system. Each of these subsystems will be reviewed in more detail. These subsystems provide the experiment operator with the ability to monitor and/or control numerous experimental parameters.

  16. 48 CFR 1515.408 - Solicitation provisions and contract clauses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... month period(s) of performance and performance is on a Government facility; Alternate II for... dedicated staff for a twelve month period(s) of performance and performance is not on a Government facility... needed to fit an individual acquisition, and (2) 1552.215-73, General Financial and Organizational...

  17. 48 CFR 1515.408 - Solicitation provisions and contract clauses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... month period(s) of performance and performance is on a Government facility; Alternate II for... dedicated staff for a twelve month period(s) of performance and performance is not on a Government facility... needed to fit an individual acquisition, and (2) 1552.215-73, General Financial and Organizational...

  18. Model-Scale Aerodynamic Performance Testing of Proposed Modifications to the NASA Langley Low Speed Aeroacoustic Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Booth, Earl R., Jr.; Coston, Calvin W., Jr.

    2005-01-01

    Tests were performed on a 1/20th-scale model of the Low Speed Aeroacoustic Wind Tunnel to determine the performance effects of insertion of acoustic baffles in the tunnel inlet, replacement of the existing collector with a new collector design in the open jet test section, and addition of flow splitters to the acoustic baffle section downstream of the test section. As expected, the inlet baffles caused a reduction in facility performance. About half of the performance loss was recovered by addition the flow splitters to the downstream baffles. All collectors tested reduced facility performance. However, test chamber recirculation flow was reduced by the new collector designs and shielding of some of the microphones was reduced owing to the smaller size of the new collector. Overall performance loss in the facility is expected to be a 5 percent top flow speed reduction, but the facility will meet OSHA limits for external noise levels and recirculation in the test section will be reduced.

  19. 78 FR 55244 - Senior Executive Service Performance Review Board; Membership

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-10

    ... DEFENSE NUCLEAR FACILITIES SAFETY BOARD Senior Executive Service Performance Review Board... the membership of the Defense Nuclear Facilities Safety Board (DNFSB) Senior Executive Service (SES... rating of a senior executive's performance, the executive's response, and the higher level official's...

  20. Energy Systems Integration Facility (ESIF) Facility Stewardship Plan: Revision 2.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torres, Juan; Anderson, Art

    The U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), has established the Energy Systems Integration Facility (ESIF) on the campus of the National Renewable Energy Laboratory (NREL) and has designated it as a DOE user facility. This 182,500-ft2 research facility provides state-of-the-art laboratory and support infrastructure to optimize the design and performance of electrical, thermal, fuel, and information technologies and systems at scale. This Facility Stewardship Plan provides DOE and other decision makers with information about the existing and expected capabilities of the ESIF and the expected performance metrics to be applied to ESIF operations.more » This plan is a living document that will be updated and refined throughout the lifetime of the facility.« less

  1. Investigation of the Effects of Facility Background Pressure on the Performance and Voltage-Current Characteristics of the High Voltage Hall Accelerator

    NASA Technical Reports Server (NTRS)

    Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Spektor, Rostislav

    2014-01-01

    The National Aeronautics and Space Administration (NASA) Science Mission Directorate In-Space Propulsion Technology office is sponsoring NASA Glenn Research Center to develop a 4 kW-class Hall thruster propulsion system for implementation in NASA science missions. A study was conducted to assess the impact of varying the facility background pressure on the High Voltage Hall Accelerator (HiVHAc) thruster performance and voltage-current characteristics. This present study evaluated the HiVHAc thruster performance in the lowest attainable background pressure condition at NASA GRC Vacuum Facility 5 to best simulate space-like conditions. Additional tests were performed at selected thruster operating conditions to investigate and elucidate the underlying physics that change during thruster operation at elevated facility background pressure. Tests were performed at background pressure conditions that are three and ten times higher than the lowest realized background pressure. Results indicated that the thruster discharge specific impulse and efficiency increased with elevated facility background pressure. The voltage-current profiles indicated a narrower stable operating region with increased background pressure. Experimental observations of the thruster operation indicated that increasing the facility background pressure shifted the ionization and acceleration zones upstream towards the thrusters anode. Future tests of the HiVHAc thruster are planned at background pressure conditions that are expected to be two to three times lower than what was achieved during this test campaign. These tests will not only assess the impact of reduced facility background pressure on thruster performance, voltage-current characteristics, and plume properties; but will also attempt to quantify the magnitude of the ionization.

  2. Ballistocraft: a novel facility for microgravity research.

    PubMed

    Mesland, D; Paris, D; Huijser, R; Lammertse, P; Postema, R

    1995-05-01

    One of ESA's aims is to provide the microgravity research community with various microgravity exposure facilities. Those facilities include drop towers, sounding rockets, and parabolic flights on board aircraft, in addition to orbital spacecraft. Microgravity flights are usually achieved using large aircraft like the French 'Caravelle' that offer a large payload volume and where a person can be present to perform the experiments and to participate as a human test-subject. However, the microgravity community is also very interested in a flexible, complementary facility that would allow frequent and repetitive exposure to microgravity for a laboratory-type of payload. ESA has therefore undertaken a study of the potential of using a 'ballistocraft', a small unmanned aircraft, to provide a low-cost facility for short-duration (30-40 seconds) microgravity experimentation. Fokker Space & Systems performed the study under an ESA contract, supported by Dutch national funding. To assess the ballistocraft, a simple breadboard of the facility was built and flight tests were performed. The ability of the on-board controller to achieve automated parabolic flights was demonstrated, and the performance of the controller in one-g level flights, and in flights with both zero-g and partial-g setpoints, was evaluated. The partial-g flights are a unique and valuable feature of the facility.

  3. A longitudinal analysis of nursing home outcomes.

    PubMed Central

    Porell, F; Caro, F G; Silva, A; Monane, M

    1998-01-01

    OBJECTIVE: To investigate resident and facility attributes associated with long-term care health outcomes in nursing homes. DATA SOURCES: Quarterly Management Minutes Questionnaire (MMQ) survey data for Medicaid case-mix reimbursement of nursing homes in Massachusetts from 1991 to 1994, for specification of outcomes and resident attributes. Facility attributes are specified from cost report data. STUDY DESIGN: Multivariate logistic and "state-dependence" regression models are estimated for survival, ADL functional status, incontinence status, and mental status outcomes from longitudinal residence histories of Medicaid residents spanning 3 to 36 months in length. Outcomes are specified to be a function of resident demographic and diagnostic attributes and facility-level operating and nurse staffing attributes. PRINCIPAL FINDINGS: The estimated parameters for resident demographic and diagnostic attributes showed a great deal of construct validity with respect to clinical expectations regarding risk factors for adverse outcomes. Few facility attributes were associated with outcomes generally, and none was significantly associated with all four outcomes. CONCLUSIONS: The absence of uniform associations between facility attributes and the various long-term care health outcomes studied suggests that strong facility performance on one health outcome may coexist with much weaker performance on other outcomes. This has implications for the aggregation of individual facility performance measures on multiple outcomes and the development of overall outcome performance measures. PMID:9776939

  4. NETL's Hybrid Performance, or Hyper, facility

    ScienceCinema

    None

    2018-02-13

    NETL's Hybrid Performance, or Hyper, facility is a one-of-a-kind laboratory built to develop control strategies for the reliable operation of fuel cell/turbine hybrids and enable the simulation, design, and implementation of commercial equipment. The Hyper facility provides a unique opportunity for researchers to explore issues related to coupling fuel cell and gas turbine technologies.

  5. The Effect of Art Therapy on Cognitive Performance among Ethnically Diverse Older Adults

    ERIC Educational Resources Information Center

    Pike, Amanda Alders

    2013-01-01

    This study examined the effect of art therapy on the cognitive performance of a multisite, ethnically diverse sample ("N" = 91) of older adults. Participants were recruited from several U.S. facilities that included a community center, a retirement center, an adult daycare, an assisted living facility, and a skilled nursing facility.…

  6. Assessing healthcare quality using routine data: evaluating the performance of the national tuberculosis programme in South Africa.

    PubMed

    McLaren, Zoë M; Sharp, Alana R; Zhou, Jifang; Wasserman, Sean; Nanoo, Ananta

    2017-02-01

    To assess the performance of healthcare facilities by means of indicators based on guidelines for clinical care of TB, which is likely a good measure of overall facility quality. We assessed quality of care in all public health facilities in South Africa using graphical, correlation and locally weighted kernel regression analysis of routine TB test data. Facility performance falls short of national standards of care. Only 74% of patients with TB provided a second specimen for testing, 18% received follow-up testing and 14% received drug resistance testing. Only resistance testing rates improved over time, tripling between 2004 and 2011. National awareness campaigns and changes in clinical guidelines had only a transient impact on testing rates. The poorest performing facilities remained at the bottom of the rankings over the period of study. The optimal policy strategy requires both broad-based policies and targeted resources to poor performers. This approach to assessing facility quality of care can be adapted to other contexts and also provides a low-cost method for evaluating the effectiveness of proposed interventions. Devising targeted policies based on routine data is a cost-effective way to improve the quality of public health care provided. © 2016 John Wiley & Sons Ltd.

  7. A survey of experiments and experimental facilities for active control of flexible structures

    NASA Technical Reports Server (NTRS)

    Sparks, Dean W., Jr.; Horner, Garnett C.; Juang, Jer-Nan; Klose, Gerhard

    1989-01-01

    A brief survey of large space structure control related experiments and facilities was presented. This survey covered experiments performed before and up to 1982, and those of the present period (1982-...). Finally, the future planned experiments and facilities in support of the control-structure interaction (CSI) program were reported. It was stated that new, improved ground test facilities are needed to verify the new CSI design techniques that will allow future space structures to perform planned NASA missions.

  8. 40 CFR 60.400 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Performance for Phosphate Rock Plants § 60.400 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities used in phosphate rock plants..., calciners, grinders, and ground rock handling and storage facilities, except those facilities producing or...

  9. 40 CFR 60.400 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Performance for Phosphate Rock Plants § 60.400 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities used in phosphate rock plants..., calciners, grinders, and ground rock handling and storage facilities, except those facilities producing or...

  10. 40 CFR 60.400 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Performance for Phosphate Rock Plants § 60.400 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities used in phosphate rock plants..., calciners, grinders, and ground rock handling and storage facilities, except those facilities producing or...

  11. 40 CFR 60.400 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Performance for Phosphate Rock Plants § 60.400 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities used in phosphate rock plants..., calciners, grinders, and ground rock handling and storage facilities, except those facilities producing or...

  12. 40 CFR 60.400 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Phosphate Rock Plants § 60.400 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities used in phosphate rock plants..., calciners, grinders, and ground rock handling and storage facilities, except those facilities producing or...

  13. Take a Tour of Our Facility | Energy Systems Integration Facility | NREL

    Science.gov Websites

    Take a Tour of Our Facility Take a Tour of Our Facility The Energy Systems Integration Facility Optical Characterization Laboratory System Performance Laboratory Power Systems Integration Laboratory Control Room Energy Storage Laboratory Outdoor Testing Areas Outdoor Testing Areas Energy Systems

  14. Development of an Enhanced Payback Function for the Superior Energy Performance Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Therkelsen, Peter; Rao, Prakash; McKane, Aimee

    2015-08-03

    The U.S. DOE Superior Energy Performance (SEP) program provides recognition to industrial and commercial facilities that achieve certification to the ISO 50001 energy management system standard and third party verification of energy performance improvements. Over 50 industrial facilities are participating and 28 facilities have been certified in the SEP program. These facilities find value in the robust, data driven energy performance improvement result that the SEP program delivers. Previous analysis of SEP certified facility data demonstrated the cost effectiveness of SEP and identified internal staff time to be the largest cost component related to SEP implementation and certification. This papermore » analyzes previously reported and newly collected data of costs and benefits associated with the implementation of an ISO 50001 and SEP certification. By disaggregating “sunk energy management system (EnMS) labor costs”, this analysis results in a more accurate and detailed understanding of the costs and benefits of SEP participation. SEP is shown to significantly improve and sustain energy performance and energy cost savings, resulting in a highly attractive return on investment. To illustrate these results, a payback function has been developed and is presented. On average facilities with annual energy spend greater than $2M can expect to implement SEP with a payback of less than 1.5 years. Finally, this paper also observes and details decreasing facility costs associated with implementing ISO 50001 and certifying to the SEP program, as the program has improved from pilot, to demonstration, to full launch.« less

  15. Tuberculosis in the workplace: OSHA's compliance experience.

    PubMed

    McDiarmid, M; Gamponia, M J; Ryan, M A; Hirshon, J M; Gillen, N A; Cox, M

    1996-03-01

    Inspections of 272 facilities were performed between May 1992 and October 1994 to determine compliance with applicable Occupational Safety and Health Administration (OSHA) requirements for prevention of tuberculosis (TB) transmission. Retrospective record review of two data sources: (1) OSHA's Computerized Integrated Management Information System and (2) an inspector-completed questionnaire on inspection results. Inspections of five types of facilities: healthcare institutions, correctional facilities, homeless shelters, long-term-care facilities for the elderly, and others, including drug treatment centers that the Centers for Disease Control and Prevention (CDC) identified as having a higher than expected rate of TB. The OSHA Compliance Memorandum, based on the 1990 CDC Guidelines, which outlined elements of a TB prevention program, was used in performing 272 inspections of facilities between May 1992 and October 1994. Elements of compliance were recorded and reviewed from the IMIS database and inspectors' questionnaires. Regulated facilities were not fully compliant with OSHA guidance. Generally, healthcare facilities performed better than other facilities. Most facilities (79%) were compliant with administrative elements of a comprehensive TB control program, such as early identification of known or suspected infectious TB patients and skin testing of workers. Only 29% of inspected facilities were found to have acceptable respiratory protection programs for the prevention of occupational TB. Facilities have not been fully compliant with the OSHA memorandum describing protection of workers from TB. Facility compliance was better with some traditionally recognized TB infection control elements, but was weaker in the area of respiratory protection programs. This may reflect a lack of familiarity with the latter type of hazard protection.

  16. 42 CFR 493.1100 - Condition: Facility administration.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Facility administration. 493.1100... SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Facility Administration for Nonwaived Testing § 493.1100 Condition: Facility administration. Each laboratory that performs nonwaived...

  17. 40 CFR 60.290 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Glass Manufacturing Plants § 60.290 Applicability and designation of affected facility. (a...

  18. 40 CFR 60.80 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sulfuric Acid Plants § 60.80 Applicability and designation of affected facility. (a) The...

  19. 40 CFR 60.80 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sulfuric Acid Plants § 60.80 Applicability and designation of affected facility. (a) The...

  20. (abstract) Simple Spreadsheet Thermal Models for Cryogenic Applications

    NASA Technical Reports Server (NTRS)

    Nash, A. E.

    1994-01-01

    Self consistent circuit analog thermal models, that can be run in commercial spreadsheet programs on personal computers, have been created to calculate the cooldown and steady state performance of cryogen cooled Dewars. The models include temperature dependent conduction and radiation effects. The outputs of the models provide temperature distribution and Dewar performance information. These models have been used to analyze the Cryogenic Telescope Test Facility (CTTF). The facility will be on line in early 1995 for its first user, the Infrared Telescope Technology Testbed (ITTT), for the Space Infrared Telescope Facility (SIRTF) at JPL. The model algorithm as well as a comparison of the model predictions and actual performance of this facility will be presented.

  1. Simple Spreadsheet Thermal Models for Cryogenic Applications

    NASA Technical Reports Server (NTRS)

    Nash, Alfred

    1995-01-01

    Self consistent circuit analog thermal models that can be run in commercial spreadsheet programs on personal computers have been created to calculate the cooldown and steady state performance of cryogen cooled Dewars. The models include temperature dependent conduction and radiation effects. The outputs of the models provide temperature distribution and Dewar performance information. these models have been used to analyze the SIRTF Telescope Test Facility (STTF). The facility has been brought on line for its first user, the Infrared Telescope Technology Testbed (ITTT), for the Space Infrared Telescope Facility (SIRTF) at JPL. The model algorithm as well as a comparison between the models' predictions and actual performance of this facility will be presented.

  2. Instrument Systems Analysis and Verification Facility (ISAVF) users guide

    NASA Technical Reports Server (NTRS)

    Davis, J. F.; Thomason, J. O.; Wolfgang, J. L.

    1985-01-01

    The ISAVF facility is primarily an interconnected system of computers, special purpose real time hardware, and associated generalized software systems, which will permit the Instrument System Analysts, Design Engineers and Instrument Scientists, to perform trade off studies, specification development, instrument modeling, and verification of the instrument, hardware performance. It is not the intent of the ISAVF to duplicate or replace existing special purpose facilities such as the Code 710 Optical Laboratories or the Code 750 Test and Evaluation facilities. The ISAVF will provide data acquisition and control services for these facilities, as needed, using remote computer stations attached to the main ISAVF computers via dedicated communication lines.

  3. Cryogenic Test Capability at Marshall Space Flight Center's X-ray Cryogenic Test Facility

    NASA Technical Reports Server (NTRS)

    Kegley, Jeffrey; Baker, Mark; Carpenter, Jay; Eng, Ron; Haight, Harlan; Hogue, William; McCracken, Jeff; Siler, Richard; Wright, Ernie

    2006-01-01

    Marshall Space Flight Center's X-ray & Cryogenic Test Facility (XRCF) has been performing sub-liquid nitrogen temperature testing since 1999. Optical wavefront measurement, thermal structural deformation, mechanism functional & calibration, and simple cryo-conditioning tests have been completed. Recent modifications have been made to the facility in support of the James Webb Space Telescope (JWST) program. The chamber's payload envelope and the facility s refrigeration capacity have both been increased. Modifications have also been made to the optical instrumentation area improving access for both the installation and operation of optical instrumentation outside the vacuum chamber. The facility's capabilities, configuration, and performance data will be presented.

  4. Addressing social aspects associated with wastewater treatment facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padilla-Rivera, Alejandro; Morgan-Sagastume, Juan Manuel; Noyola, Adalberto

    In wastewater treatment facilities (WWTF), technical and financial aspects have been considered a priority, while other issues, such as social aspects, have not been evaluated seriously and there is not an accepted methodology for assessing it. In this work, a methodology focused on social concerns related to WWTF is presented. The methodology proposes the use of 25 indicators as a framework for measuring social performance to evaluate the progress in moving towards sustainability. The methodology was applied to test its applicability and effectiveness in two WWTF in Mexico (urban and rural). This evaluation helped define the key elements, stakeholders andmore » barriers in the facilities. In this context, the urban facility showed a better overall performance, a result that may be explained mainly by the better socioeconomic context of the urban municipality. Finally, the evaluation of social aspects using the semi-qualitative approach proposed in this work allows for a comparison between different facilities and for the identification of strengths and weakness, and it provides an alternative tool for achieving and improving wastewater management. - Highlights: • The methodology proposes 25 indicators as a framework for measuring social performance in wastewater treatment facilities. • The evaluation helped to define the key elements, stakeholders and barriers in the wastewater treatment facilities. • The evaluation of social aspects allows the identification of strengths and weakness for improving wastewater management. • It provides a social profile of the facility that highlights the best and worst performances.« less

  5. 40 CFR 60.70 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Nitric Acid Plants § 60.70 Applicability and designation of affected facility. (a) The provisions...

  6. 40 CFR 60.70 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Nitric Acid Plants § 60.70 Applicability and designation of affected facility. (a) The provisions...

  7. 10 CFR 55.4 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... means testing conducted to verify a simulation facility's performance as compared to actual or predicted... which a simulation facility's control room configuration, system control arrangement, and design data... of a facility and to direct the licensed activities of licensed operators. Simulation facility means...

  8. 10 CFR 55.4 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... means testing conducted to verify a simulation facility's performance as compared to actual or predicted... which a simulation facility's control room configuration, system control arrangement, and design data... of a facility and to direct the licensed activities of licensed operators. Simulation facility means...

  9. 10 CFR 55.4 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... means testing conducted to verify a simulation facility's performance as compared to actual or predicted... which a simulation facility's control room configuration, system control arrangement, and design data... of a facility and to direct the licensed activities of licensed operators. Simulation facility means...

  10. Urban Watershed Research Facility at Edison Environmental Center

    EPA Science Inventory

    The Urban Watershed Research Facility (UWRF) is an isolated, 20-acre open space within EPA’s 200 acre Edison facility established to develop and evaluate the performance of stormwater management practices under controlled conditions. The facility includes greenhouses that allow ...

  11. 40 CFR 60.260 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... affected facility. 60.260 Section 60.260 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Ferroalloy Production Facilities § 60.260 Applicability and designation of affected facility..., ferrochrome silicon, silvery iron, high-carbon ferrochrome, charge chrome, standard ferromanganese...

  12. 40 CFR 60.260 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... affected facility. 60.260 Section 60.260 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Ferroalloy Production Facilities § 60.260 Applicability and designation of affected facility..., ferrochrome silicon, silvery iron, high-carbon ferrochrome, charge chrome, standard ferromanganese...

  13. Facility Maintenance. V-TECS Guide.

    ERIC Educational Resources Information Center

    Moore, Charles G.; And Others

    This facility maintenance guide is a compilation of duties, tasks, performance objectives, and performance guides that deals with the psychomotor aspect of an occupation. The guide addresses the three domains of learning: psychomotor, cognitive, and affective. Each unit provides job-relevant tasks, standards of performance, source of standard,…

  14. Investigation of the Effects of Facility Background Pressure on the Performance and Voltage-Current Characteristics of the High Voltage Hall Accelerator

    NASA Technical Reports Server (NTRS)

    Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Spektor, Rostislav

    2014-01-01

    The National Aeronautics and Space Administration (NASA) Science Mission Directorate In-Space Propulsion Technology office is sponsoring NASA Glenn Research Center to develop a 4 kW-class Hall thruster propulsion system for implementation in NASA science missions. A study was conducted to assess the impact of varying the facility background pressure on the High Voltage Hall Accelerator (HiVHAc) thruster performance and voltage-current characteristics. This present study evaluated the HiVHAc thruster performance in the lowest attainable background pressure condition at NASA GRC Vacuum Facility 5 to best simulate space-like conditions. Additional tests were performed at selected thruster operating conditions to investigate and elucidate the underlying physics that change during thruster operation at elevated facility background pressure. Tests were performed at background pressure conditions that are three and ten times higher than the lowest realized background pressure. Results indicated that the thruster discharge specific impulse and efficiency increased with elevated facility background pressure. The voltage-current profiles indicated a narrower stable operating region with increased background pressure. Experimental observations of the thruster operation indicated that increasing the facility background pressure shifted the ionization and acceleration zones upstream towards the thruster's anode. Future tests of the HiVHAc thruster are planned at background pressure conditions that are expected to be two to three times lower than what was achieved during this test campaign. These tests will not only assess the impact of reduced facility background pressure on thruster performance, voltage-current characteristics, and plume properties; but will also attempt to quantify the magnitude of the ionization and acceleration zones upstream shifting as a function of increased background pressure.

  15. RETROFITTING POTW

    EPA Science Inventory

    This manual is intended as a source document for individuals responsible for improving the performance of an existing, non-complying wastewater treatment facility. Described are: 1) methods to evaluate an existing facility's capability to achieve improved performance, 2) a ...

  16. 76 FR 44591 - Notice of Hearing: Reconsideration of Disapproval of Indiana State Plan Amendments (SPA) 11-011

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-26

    ... perform abortions or maintain or operate facilities where abortions are performed, except for hospitals or... restrictions on Federal funding of abortion services. Section 1116 of the Act and Federal regulations at 42 CFR... providers that perform abortions or maintain or operate facilities where abortions are performed, except for...

  17. Coverage of emergency obstetric care and availability of services in public and private health facilities in Bangladesh.

    PubMed

    Alam, Badrul; Mridha, Malay K; Biswas, Taposh K; Roy, Lumbini; Rahman, Maksudur; Chowdhury, Mahbub E

    2015-10-01

    To assess the coverage of emergency obstetric care (EmOC) and the availability of obstetric services in Bangladesh. In a national health facility assessment performed between November 2007 and July 2008, all public EmOC facilities and private facilities providing obstetric services in the 64 districts of Bangladesh were mapped. The performance of EmOC services in these facilities during the preceding month was investigated using a semi-structured questionnaire completed through interviews of managers and service providers, and record review. In total, 8.6 (2.1 public and 6.5 private) facilities per 500000 population offered obstetric care services. Population coverage by obstetric care facilities varied by region. Among 281 public facilities designated for comprehensive EmOC, cesarean delivery was available in only 215 (76.5%) and blood transfusion services in 198 (70.5%). In the private sector (for profit and not for profit), these services were available in more than 80% of facilities. In all facility types, performance of assisted vaginal delivery (range 12.2%-48.4%) and use of parenteral anticonvulsants to treat pre-eclampsia/eclampsia (range 48.6%-80.8%) were low. The main reason for non-availability of EmOC services was a lack of specialist/trained providers. Bangladesh needs to increase the availability of EmOC services through innovative public-private partnerships. In the public sector, additional trained manpower supported by an incentivized package should be deployed. Copyright © 2015. Published by Elsevier Ireland Ltd.

  18. Association between access to accelerated partial breast irradiation and use of adjuvant radiotherapy.

    PubMed

    Wang, Elyn H; Park, Henry S; Rutter, Charles E; Gross, Cary P; Soulos, Pamela R; Yu, James B; Evans, Suzanne B

    2017-02-01

    The current study was performed to determine whether access to facilities performing accelerated partial breast irradiation (APBI) is associated with differences in the use of adjuvant radiotherapy (RT). Using the National Cancer Data Base, the authors performed a retrospective study of women aged ≥50 years who were diagnosed with early-stage breast cancer between 2004 and 2013 and treated with breast-conserving surgery (BCS). Facilities performing APBI in ≥10% of their eligible patients within a given year were defined as APBI facilities whereas those not performing APBI were defined as non-APBI facilities. All other facilities were excluded. The authors identified independent factors associated with RT use using multivariable logistic regression with clustering in the overall sample as well as in subsets of patients with standard-risk invasive cancer, low-risk invasive cancer, and ductal carcinoma in situ. Among 222,544 patients, 76.6% underwent BCS plus RT and 23.4% underwent BCS alone. The likelihood of RT receipt in the overall sample did not appear to differ significantly between APBI and non-APBI facilities (adjusted odds ratio [AOR], 1.02; P = .61). Subgroup multivariable analysis demonstrated that among patients with standard-risk invasive cancer, there was no association between evaluation at an APBI facility and receipt of RT (AOR, 0.98; P = .69). However, patients with low-risk invasive cancer were found to be significantly more likely to receive RT (54.4% vs 59.5%; AOR, 1.22 [P<.001]), whereas patients with ductal carcinoma in situ were less likely to receive RT (56.9% vs 55.3%; AOR, 0.89 [P = .04]) at APBI facilities. Patients who were eligible for observation were more likely to receive RT in APBI facilities but no difference was observed among patients with standard-risk invasive cancer who would most benefit from RT. Cancer 2017;123:502-511. © 2016 American Cancer Society. © 2016 American Cancer Society.

  19. Survey of brachytherapy practice in the United States: a report of the Clinical Research Committee of the American Endocurietherapy Society.

    PubMed

    Nag, S; Owen, J B; Farnan, N; Pajak, T F; Martinez, A; Porter, A; Blasko, J; Harrison, L B

    1995-01-01

    To obtain reliable data on the extent of the brachytherapy practice in the United States by conducting a comprehensive survey of all facilities. The Clinical Research Committee of the AES surveyed all 1321 radiation oncology facilities identified in the Patterns of Care Study (PCS) of the American College of Radiology (ACR). Multiple mailings and follow-up were made to obtain a high response rate. Survey responders and nonresponders were compared using chi-square tests. Summary statistics were reported. Of the 1321 facilities, 1054 responded (80%). Hospital-based and larger facilities had a statistically significant higher rate of response. Brachytherapy was being performed at 819 facilities (the median number of procedures = 21-50). Two hundred and two facilities did no brachytherapy. The common isotopes used were 137Cs (705 facilities), 192Ir (585 facilities), 125I (236 facilities), and 131I (194 facilities). The common brachytherapy techniques used were intracavitary (751 facilities), interstitial (536 facilities), intraluminal (310 facilities), and plaques (148 facilities). Remote afterloaded brachytherapy was used at 205 centers as follows: high dose rate (HDR) (164), medium dose rate (MDR) (5), and low dose rate (LDR) (36). Computerized dosimetry was most commonly used (790 facilities), followed by Patterson-Parker (104 facilities) and Quimby (72 facilities). The common sites treated were cervix (701 facilities), endometrium (565 facilities), head and neck (354 facilities), and lung (344 facilities). Data regarding brachytherapy practice has been obtained from a large percentage (80%) of all facilities in the United States. The majority (78-81%) of radiation oncology facilities perform brachytherapy; however, its use is restricted to gynecological implants in many of these centers. The results from this survey will be used to develop a pattern of care study and data registry in brachytherapy.

  20. The Proposal of Key Performance Indicators in Facility Management and Determination the Weights of Significance

    NASA Astrophysics Data System (ADS)

    Rimbalová, Jarmila; Vilčeková, Silvia

    2013-11-01

    The practice of facilities management is rapidly evolving with the increasing interest in the discourse of sustainable development. The industry and its market are forecasted to develop to include non-core functions, activities traditionally not associated with this profession, but which are increasingly being addressed by facilities managers. The scale of growth in the built environment and the consequential growth of the facility management sector is anticipated to be enormous. Key Performance Indicators (KPI) are measure that provides essential information about performance of facility services delivery. In selecting KPI, it is critical to limit them to those factors that are essential to the organization reaching its goals. It is also important to keep the number of KPI small just to keep everyone's attention focused on achieving the same KPIs. This paper deals with the determination of weights of KPI of FM in terms of the design and use of sustainable buildings.

  1. Capital Ideas for Facilities Management.

    ERIC Educational Resources Information Center

    Golding, Stephen T.; Gordon, Janet; Gravina, Arthur

    2001-01-01

    Asserting that just like chief financial officers, higher education facilities specialists must maximize the long-term performance of assets under their care, describes strategies for strategic facilities management. Discusses three main approaches to facilities management (insourcing, cosourcing, and outsourcing) and where boards of trustees fit…

  2. Minnesota's Nursing Facility Performance-Based Incentive Payment Program: An Innovative Model for Promoting Care Quality

    ERIC Educational Resources Information Center

    Cooke, Valerie; Arling, Greg; Lewis, Teresa; Abrahamson, Kathleen A.; Mueller, Christine; Edstrom, Lisa

    2010-01-01

    Purpose: Minnesota's Nursing Facility Performance-Based Incentive Payment Program (PIPP) supports provider-initiated projects aimed at improving care quality and efficiency. PIPP moves beyond conventional pay for performance. It seeks to promote implementation of evidence-based practices, encourage innovation and risk taking, foster collaboration…

  3. Simulation of mass storage systems operating in a large data processing facility

    NASA Technical Reports Server (NTRS)

    Holmes, R.

    1972-01-01

    A mass storage simulation program was written to aid system designers in the design of a data processing facility. It acts as a tool for measuring the overall effect on the facility of on-line mass storage systems, and it provides the means of measuring and comparing the performance of competing mass storage systems. The performance of the simulation program is demonstrated.

  4. Surface evaluation of UV-degraded contamination

    NASA Technical Reports Server (NTRS)

    Connatser, Robert; Hadaway, James B.

    1992-01-01

    Three different areas of work were accomplished under this contract: (1) contamination testing and evaluation; (2) UV irradiation testing; and (3) surface evaluation testing. Contamination testing was generally performed in the In-Situ Contamination Effects Facility at Marshall Space Flight Center (MSFC). UV irradiation testing was also performed primarily at MSFC, utilizing facilities there. Finally, the surface evaluation was done at facilities at UAH Center for Applied Optics.

  5. Assessing patient safety in Canadian ambulatory surgery facilities: A national survey

    PubMed Central

    Ahmad, Jamil; Ho, Olivia A; Carman, Wayne W; Thoma, Achilles; Lalonde, Donald H; Lista, Frank

    2014-01-01

    BACKGROUND: There has been increased interest regarding patient safety and standards of care in Canadian ambulatory surgery facilities where surgical procedures are performed. The Canadian Association for Accreditation of Ambulatory Surgical Facilities (CAAASF) is a national organization formed to establish and maintain standards to ensure that surgical procedures conducted outside of public hospitals are performed safely. OBJECTIVE: To determine how many procedures are performed annually at CAAASF member sites, and to examine complication rates and several key patient safety practices. METHODS: All 69 facilities accredited by the CAAASF were surveyed. The survey focused on procedural data, complication rates and patient safety interventions. RESULTS: In 2010, 40,240 estimated procedures were performed. A total of 263 (0.007%) complications were reported. Sixteen (0.0004%) patients required reoperations in hospital and 19 (0.0004%) patients required transfer to hospital on the day of surgery. There were only two mortalities within 30 days of surgery reported in the past five years. With regard to patient safety practices, 93% used antimicrobial prophylaxis, 100% used strategies to maintain normothermia and 82% used measures for venous thromboembolism prevention. CONCLUSION: The present study is the first to report on the Canadian experience in ambulatory surgery facilities and provides insight into current practices at these facilities. Appropriate accreditation of ambulatory surgery facilities, well-established patient safety-related standards of care, careful patient selection and procedures performed by qualified health care professionals with appropriate certification practicing within the scope of their practice form the basis for safe and effective ambulatory surgery. PMID:25152645

  6. An automated system for positive reinforcement training of group-housed macaque monkeys at breeding and research facilities.

    PubMed

    Tulip, Jennifer; Zimmermann, Jonas B; Farningham, David; Jackson, Andrew

    2017-06-15

    Behavioural training through positive reinforcement techniques is a well-recognised refinement to laboratory animal welfare. Behavioural neuroscience research requires subjects to be trained to perform repetitions of specific behaviours for food/fluid reward. Some animals fail to perform at a sufficient level, limiting the amount of data that can be collected and increasing the number of animals required for each study. We have implemented automated positive reinforcement training systems (comprising a button press task with variable levels of difficulty using LED cues and a fluid reward) at the breeding facility and research facility, to compare performance across these different settings, to pre-screen animals for selection and refine training protocols. Animals learned 1- and 4-choice button tasks within weeks of home enclosure training, with some inter-individual differences. High performance levels (∼200-300 trials per 60min session at ∼80% correct) were obtained without food or fluid restriction. Moreover, training quickly transferred to a laboratory version of the task. Animals that acquired the task at the breeding facility subsequently performed better both in early home enclosure sessions upon arrival at the research facility, and also in laboratory sessions. Automated systems at the breeding facility may be used to pre-screen animals for suitability for behavioural neuroscience research. In combination with conventional training, both the breeding and research facility systems facilitate acquisition and transference of learning. Automated systems have the potential to refine training protocols and minimise requirements for food/fluid control. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  7. TRAC analyses for CCTF and SCTF tests and UPTF design/operation. [Cylindrical Core Test Facility; Slab Core Test Facility; Upper Plenum Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spore, J.W.; Cappiello, M.W.; Dotson, P.J.

    The analytical support in 1985 for Cylindrical Core Test Facility (CCTF), Slab Core Test Facility (SCTF), and Upper Plenum Test Facility (UPTF) tests involves the posttest analysis of 16 tests that have already been run in the CCTF and the SCTF and the pretest analysis of 3 tests to be performed in the UPTF. Posttest analysis is used to provide insight into the detailed thermal-hydraulic phenomena occurring during the refill and reflood tests performed in CCTF and SCTF. Pretest analysis is used to ensure that the test facility is operated in a manner consistent with the expected behavior of anmore » operating full-scale plant during an accident. To obtain expected behavior of a plant during an accident, two plant loss-of-coolant-accident (LOCA) calculations were performed: a 200% cold-leg-break LOCA calculation for a 2772 MW(t) Babcock and Wilcox plant and a 200% cold-leg-break LOCA calculation for a 3315 MW(t) Westinghouse plant. Detailed results are presented for several CCTF UPI tests and the Westinghouse plant analysis.« less

  8. Lessons Learned from Radioactive Waste Storage and Disposal Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Esh, David W.; Bradford, Anna H.

    2008-01-15

    The safety of radioactive waste disposal facilities and the decommissioning of complex sites may be predicated on the performance of engineered and natural barriers. For assessing the safety of a waste disposal facility or a decommissioned site, a performance assessment or similar analysis is often completed. The analysis is typically based on a site conceptual model that is developed from site characterization information, observations, and, in many cases, expert judgment. Because waste disposal facilities are sited, constructed, monitored, and maintained, a fair amount of data has been generated at a variety of sites in a variety of natural systems. Thismore » paper provides select examples of lessons learned from the observations developed from the monitoring of various radioactive waste facilities (storage and disposal), and discusses the implications for modeling of future waste disposal facilities that are yet to be constructed or for the development of dose assessments for the release of decommissioning sites. Monitoring has been and continues to be performed at a variety of different facilities for the disposal of radioactive waste. These include facilities for the disposal of commercial low-level waste (LLW), reprocessing wastes, and uranium mill tailings. Many of the lessons learned and problems encountered provide a unique opportunity to improve future designs of waste disposal facilities, to improve dose modeling for decommissioning sites, and to be proactive in identifying future problems. Typically, an initial conceptual model was developed and the siting and design of the disposal facility was based on the conceptual model. After facility construction and operation, monitoring data was collected and evaluated. In many cases the monitoring data did not comport with the original site conceptual model, leading to additional investigation and changes to the site conceptual model and modifications to the design of the facility. The following cases are discussed: commercial LLW disposal facilities; uranium mill tailings disposal facilities; and reprocessing waste storage and disposal facilities. The observations developed from the monitoring and maintenance of waste disposal and storage facilities provide valuable lessons learned for the design and modeling of future waste disposal facilities and the decommissioning of complex sites.« less

  9. Impact of a function-based payment model on the financial performance of acute inpatient medical rehabilitation providers: a simulation analysis.

    PubMed

    Sutton, J P; DeJong, G; Song, H; Wilkerson, D

    1997-12-01

    To operationalize research findings about a medical rehabilitation classification and payment model by building a prototype of a prospective payment system, and to determine whether this prototype model promotes payment equity. This latter objective is accomplished by identifying whether any facility or payment model characteristics are systematically associated with financial performance. This study was conducted in two phases. In Phase 1 the components of a diagnosis-related group (DRG)-like payment system, including a base rate, function-related group (FRG) weights, and adjusters, were identified and estimated using hospital cost functions. Phase 2 consisted of a simulation analysis in which each facility's financial performance was modeled, based on its 1990-1991 case mix. A multivariate regression equation was conducted to assess the extent to which characteristics of 42 rehabilitation facilities contribute toward determining financial performance under the present Medicare payment system as well as under the hypothetical model developed. Phase 1 (model development) included 61 rehabilitation hospitals. Approximately 59% were rehabilitation units within a general hospital and 48% were teaching facilities. The number of rehabilitation beds averaged 52. Phase 2 of the stimulation analysis included 42 rehabilitation facilities, subscribers to UDS in 1990-1991. Of these, 69% were rehabilitation units and 52% were teaching facilities. The number of rehabilitation beds averaged 48. Financial performance, as measured by the ratio of reimbursement to average costs. Case-mix index is the primary determinant of financial performance under the present Medicare payment system. None of the facility characteristics included in this analysis were associated with financial performance under the hypothetical FRG payment model. The most notable impact of an FRG-based payment model would be to create a stronger link between resource intensity and level of reimbursement, resulting in greater equity in the reimbursement of inpatient medical rehabilitation hospitals.

  10. Planning and Equipping Industrial Arts Facilities.

    ERIC Educational Resources Information Center

    Maine State Dept. of Educational and Cultural Services, Augusta. Bureau of Vocational Education.

    Architectural details, planning, and facility guidelines for industrial arts facilities are given, with data on planning the number, shape, size, and location of school shops. Industrial art programing and performance criteria for varying levels of education are discussed with regard for the different shop curriculums. The facility planning is…

  11. A performance goal-based seismic design philosophy for waste repository facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hossain, Q.A.

    1994-12-31

    A performance goal-based seismic design philosophy, compatible with DOE`s present natural phenomena hazards mitigation and {open_quotes}graded approach{close_quotes} philosophy, has been proposed for high level nuclear waste repository facilities. The rationale, evolution, and the desirable features of this method have been described. Why and how the method should and can be applied to the design of a repository facility are also discussed.

  12. Application of a Bimetallic Treatment System (BTS) for PCB Removal from Older Structures on DoD Facilities. Cost and Performance Report

    DTIC Science & Technology

    2011-11-01

    Bimetallic Treatment System (BTS) for PCB Removal from Older Structures on DoD Facilities By Thomas Krug and Suzanne O’Hara, Geosyntec...COST AND PERFORMANCE REPORT FOR: Application of a Bimetallic Treatment System (BTS) for PCB Removal from Older Structures on DOD Facilities...11 3.4 Reduction in PCB concentrations in treated paint to less

  13. Facility and Laboratory Equipment | Energy Systems Integration Facility |

    Science.gov Websites

    Energy Systems Integration Facility is its infrastructure. In addition to extensive fixed laboratory . Photo of researchers testing building loads and power networks in the Systems Performance Laboratory

  14. Evaluating building performance in healthcare facilities: an organizational perspective.

    PubMed

    Steinke, Claudia; Webster, Lynn; Fontaine, Marie

    2010-01-01

    Using the environment as a strategic tool is one of the most cost-effective and enduring approaches for improving public health; however, it is one that requires multiple perspectives. The purpose of this article is to highlight an innovative methodology that has been developed for conducting comprehensive performance evaluations in public sector health facilities in Canada. The building performance evaluation methodology described in this paper is a government initiative. The project team developed a comprehensive building evaluation process for all new capital health projects that would respond to the aforementioned need for stakeholders to be more accountable and to better integrate the larger organizational strategy of facilities. The Balanced Scorecard, which is a multiparadigmatic, performance-based business framework, serves as the underlying theoretical framework for this initiative. It was applied in the development of the conceptual model entitled the Building Performance Evaluation Scorecard, which provides the following benefits: (1) It illustrates a process to link facilities more effectively to the overall mission and goals of an organization; (2) It is both a measurement and a management system that has the ability to link regional facilities to measures of success and larger business goals; (3) It provides a standardized methodology that ensures consistency in assessing building performance; and (4) It is more comprehensive than traditional building evaluations. The methodology presented in this paper is both a measurement and management system that integrates the principles of evidence-based design with the practices of pre- and post-occupancy evaluation. It promotes accountability and continues throughout the life cycle of a project. The advantage of applying this framework is that it engages health organizations in clarifying a vision and strategy for their facilities and helps translate those strategies into action and measurable performance outcomes.

  15. Characterization of in-flight performance of ion propulsion systems

    NASA Astrophysics Data System (ADS)

    Sovey, James S.; Rawlin, Vincent K.

    1993-06-01

    In-flight measurements of ion propulsion performance, ground test calibrations, and diagnostic performance measurements were reviewed. It was found that accelerometers provided the most accurate in-flight thrust measurements compared with four other methods that were surveyed. An experiment has also demonstrated that pre-flight alignment of the thrust vector was sufficiently accurate so that gimbal adjustments and use of attitude control thrusters were not required to counter disturbance torques caused by thrust vector misalignment. The effects of facility background pressure, facility enhanced charge-exchange reactions, and contamination on ground-based performance measurements are also discussed. Vacuum facility pressures for inert-gas ion thruster life tests and flight qualification tests will have to be less than 2 mPa to ensure accurate performance measurements.

  16. Characterization of in-flight performance of ion propulsion systems

    NASA Technical Reports Server (NTRS)

    Sovey, James S.; Rawlin, Vincent K.

    1993-01-01

    In-flight measurements of ion propulsion performance, ground test calibrations, and diagnostic performance measurements were reviewed. It was found that accelerometers provided the most accurate in-flight thrust measurements compared with four other methods that were surveyed. An experiment has also demonstrated that pre-flight alignment of the thrust vector was sufficiently accurate so that gimbal adjustments and use of attitude control thrusters were not required to counter disturbance torques caused by thrust vector misalignment. The effects of facility background pressure, facility enhanced charge-exchange reactions, and contamination on ground-based performance measurements are also discussed. Vacuum facility pressures for inert-gas ion thruster life tests and flight qualification tests will have to be less than 2 mPa to ensure accurate performance measurements.

  17. 40 CFR 60.330 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Performance for Stationary Gas Turbines § 60.330 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities: All stationary gas turbines...

  18. 40 CFR 60.330 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Stationary Gas Turbines § 60.330 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities: All stationary gas turbines...

  19. 40 CFR 60.330 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Performance for Stationary Gas Turbines § 60.330 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities: All stationary gas turbines...

  20. 40 CFR 60.330 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Performance for Stationary Gas Turbines § 60.330 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities: All stationary gas turbines...

  1. 40 CFR 60.170 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Primary Zinc Smelters § 60.170 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities in primary zinc smelters...

  2. 40 CFR 60.330 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Performance for Stationary Gas Turbines § 60.330 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities: All stationary gas turbines...

  3. Upgrade of the cryogenic CERN RF test facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pirotte, O.; Benda, V.; Brunner, O.

    2014-01-29

    With the large number of superconducting radiofrequency (RF) cryomodules to be tested for the former LEP and the present LHC accelerator a RF test facility was erected early in the 1990’s in the largest cryogenic test facility at CERN located at Point 18. This facility consisted of four vertical test stands for single cavities and originally one and then two horizontal test benches for RF cryomodules operating at 4.5 K in saturated helium. CERN is presently working on the upgrade of its accelerator infrastructure, which requires new superconducting cavities operating below 2 K in saturated superfluid helium. Consequently, the RFmore » test facility has been renewed in order to allow efficient cavity and cryomodule tests in superfluid helium and to improve its thermal performances. The new RF test facility is described and its performances are presented.« less

  4. Arts Education Facilities Planner for Grades K-8.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Public Instruction, Raleigh.

    This reference document for public school facility designers addresses arts education programs and the facilities that support them. Some sections focus on concepts and features common to most or all arts education subject areas, such as sound management, acoustical design, teacher workstations, and performance facilities. Other sections describe…

  5. An inventory of aeronautical ground research facilities. Volume 3: Structural

    NASA Technical Reports Server (NTRS)

    Pirrello, C. J.; Hardin, R. D.; Heckart, M. V.; Brown, K. R.

    1971-01-01

    An inventory of test facilities for conducting acceleration, environmental, impact, structural shock, load, heat, vibration, and noise tests is presented. The facility is identified with a description of the equipment, the testing capabilities, and cost of operation. Performance data for the facility are presented in charts and tables.

  6. Customer assessment of long-term care pharmacy provider services.

    PubMed

    Clark, Thomas R

    2008-09-01

    Assess performance of long-term care pharmacy providers on key services offered to nursing facilities. Cross-sectional; nursing facility team. Random phone survey of nursing facility team members. 485 nursing facility team members (practicing in nursing facilities, interacting with > or = 1 consultant pharmacist); 46 members excluded, unable to identify facility's pharmacy provider. Directors of nursing, medical directors, and administrators were asked to rate long-term care pharmacy provider performance of eight commonly offered pharmacy services. All groups evaluated pharmacy provider performance of these services using a five-point scale. Results are broken down by employer type. Average rating for eight pharmacy services was 3.64. Top two services: "Labeling medications accurately" ranked in top 1-2 services for all groups (combined rating of 3.97) and "Provides medication administration system" ranked in top 1-3 services for all groups (combined rating of 3.95). One service, "Provides educational inservices," ranked lowest for all groups (combined rating of 3.54). In general, when looking at the eight services in combination for all providers, all services were ranked between Good and Very Good (average score of 3.64). Therefore, while the pharmacy provider is performing above average for these services, there is room for improvement in all of these services. These results can be used as a benchmark. Detailed data results and sample surveys are available online at www.ascp.com/supplements. These surveys can be used by the pharmacy provider to solicit assessments from their own facilities on these services.

  7. [Performance of Grass Swales for Controlling Pollution of Roadway Runoff in Field Experiments].

    PubMed

    Huang, Jun-jie; Shen, Qing-ran; Li, Tian

    2015-06-01

    Two different styles of grass swales were built in new Binhu region of Hefei city to monitor the flux and quality of the influent and effluent water under actual precipitation conditions, in order to evaluate the performance of water quality purification and pollution load control for roadway runoff. The results showed that both of the grass swales could effectively remove the pollutants such as TSS, COD, Pb, Cu, Cd, Zn in roadway runoff; the median EMC removal efficiencies of TSS and COD were 67.1%, 46.7% respectively,for facility I, and the median EMC removal efficiencies of TSS and COD were 78.6%, 58.6% respectively, for facility II; the concentrations of Pb, Cu, Zn in the effluent of facility II could meet the requirements of the surface water quality class V; release of nitrogen and phosphorus occurred in both facilities I and I[ in several rainfall events, mainly in heavy storms; the removal efficiencies of TP in the two grass swales were improved with the increase of influent concentration; the mean removal efficiencies of TP in facilities I and II were 14.7% and 45.4%, respectively; the load control performance of facility II for pollutants such as TSS, COD, TP, TN, NH4+ -N and NO3- -N was better than that of facility I; in the district with poor soil permeability and low ground slope, application of dry swale could achieve better performance in water quality control and pollution load reduction of roadway runoff.

  8. Assessment of Space Nuclear Thermal Propulsion Facility and Capability Needs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James Werner

    The development of a Nuclear Thermal Propulsion (NTP) system rests heavily upon being able to fabricate and demonstrate the performance of a high temperature nuclear fuel as well as demonstrating an integrated system prior to launch. A number of studies have been performed in the past which identified the facilities needed and the capabilities available to meet the needs and requirements identified at that time. Since that time, many facilities and capabilities within the Department of Energy have been removed or decommissioned. This paper provides a brief overview of the anticipated facility needs and identifies some promising concepts to bemore » considered which could support the development of a nuclear thermal propulsion system. Detailed trade studies will need to be performed to support the decision making process.« less

  9. A Multidisciplinary Research Framework on Green Schools: Infrastructure, Social Environment, Occupant Health, and Performance.

    PubMed

    Magzamen, Sheryl; Mayer, Adam P; Barr, Stephanie; Bohren, Lenora; Dunbar, Brian; Manning, Dale; Reynolds, Stephen J; Schaeffer, Joshua W; Suter, Jordan; Cross, Jennifer E

    2017-05-01

    Sustainable school buildings hold much promise to reducing operating costs, improve occupant well-being and, ultimately, teacher and student performance. However, there is a scarcity of evidence on the effects of sustainable school buildings on health and performance indicators. We sought to create a framework for a multidisciplinary research agenda that links school facilities, health, and educational outcomes. We conducted a nonsystematic review of peer review publications, government documents, organizational documents, and school climate measurement instruments. We found that studies on the impact of physical environmental factors (air, lighting, and thermal comfort) on health and occupant performance are largely independent of research on the social climate. The current literature precludes the formation of understanding the causal relation among school facilities, social climate, occupant health, and occupant performance. Given the average age of current school facilities in the United States, construction of new school facilities or retrofits of older facilities will be a major infrastructure investment for many municipalities over the next several decades. Multidisciplinary research that seeks to understand the impact of sustainable design on the health and performance of occupants will need to include both an environmental science and social science perspective to inform best practices and quantification of benefits that go beyond general measures of costs savings from energy efficiencies. © 2017, American School Health Association.

  10. Performance of a 12-coil superconducting 'bumpy torus' magnet facility.

    NASA Technical Reports Server (NTRS)

    Roth, J. R.; Holmes, A. D.; Keller, T. A.; Krawczonek, W. M.

    1972-01-01

    The NASA-Lewis 'bumpy torus' facility consists of 12 superconducting coils, each 19 cm ID and capable of 3.0 tesla on their axes. The coils are equally spaced around a toroidal array with a major diameter of 1.52 m, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.6 m in diameter. Final shakedown tests of the facility mapped out its magnetic, cryogenic, vacuum, mechanical, and electrical performance. The facility is now ready for use as a plasma physics research facility. A maximum magnetic field on the magnetic axis of 3.23 teslas has been held for a period of more than sixty minutes without a coil normalcy.

  11. Effects of ionospheric modification on system performance

    NASA Astrophysics Data System (ADS)

    Ganguly, Suman

    1989-12-01

    Controlled ionospheric modification can be used for disrupting as well as facilitating communication and radar systems. After briefly describing the results achieved with the present day ionospheric modification facilities, a scenario is presented for the generation of strong and significant ionospheric modification. A few schemes are presented for the development of modern high power facilities using the state of the art technology and then the impact of such facilities on the system performance is described.

  12. Integration Test of the High Voltage Hall Accelerator System Components

    NASA Technical Reports Server (NTRS)

    Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Pinero, Luis; Peterson, Todd; Dankanich, John

    2013-01-01

    NASA Glenn Research Center is developing a 4 kilowatt-class Hall propulsion system for implementation in NASA science missions. NASA science mission performance analysis was completed using the latest high voltage Hall accelerator (HiVHAc) and Aerojet-Rocketdyne's state-of-the-art BPT-4000 Hall thruster performance curves. Mission analysis results indicated that the HiVHAc thruster out performs the BPT-4000 thruster for all but one of the missions studied. Tests of the HiVHAc system major components were performed. Performance evaluation of the HiVHAc thruster at NASA Glenn's vacuum facility 5 indicated that thruster performance was lower than performance levels attained during tests in vacuum facility 12 due to the lower background pressures attained during vacuum facility 5 tests when compared to vacuum facility 12. Voltage-Current characterization of the HiVHAc thruster in vacuum facility 5 showed that the HiVHAc thruster can operate stably for a wide range of anode flow rates for discharge voltages between 250 and 600 volts. A Colorado Power Electronics enhanced brassboard power processing unit was tested in vacuum for 1,500 hours and the unit demonstrated discharge module efficiency of 96.3% at 3.9 kilowatts and 650 volts. Stand-alone open and closed loop tests of a VACCO TRL 6 xenon flow control module were also performed. An integrated test of the HiVHAc thruster, brassboard power processing unit, and xenon flow control module was performed and confirmed that integrated operation of the HiVHAc system major components. Future plans include continuing the maturation of the HiVHAc system major components and the performance of a single-string integration test.

  13. Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility. Part 1; Steady Predictions

    NASA Technical Reports Server (NTRS)

    Allgood, Daniel C.; Graham, Jason S.; Ahuja, Vineet; Hosangadi, Ashvin

    2010-01-01

    Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively.

  14. A feasibility study of a hypersonic real-gas facility

    NASA Technical Reports Server (NTRS)

    Gully, J. H.; Driga, M. D.; Weldon, W. F.

    1987-01-01

    A four month feasibility study of a hypersonic real-gas free flight test facility for NASA Langley Research Center (LARC) was performed. The feasibility of using a high-energy electromagnetic launcher (EML) to accelerate complex models (lifting and nonlifting) in the hypersonic, real-gas facility was examined. Issues addressed include: design and performance of the accelerator; design and performance of the power supply; design and operation of the sabot and payload during acceleration and separation; effects of high current, magnetic fields, temperature, and stress on the sabot and payload; and survivability of payload instrumentation during acceleration, flight, and soft catch.

  15. Analysis on online word-of-mouth of customer satisfaction in cultural and creative industries of Taiwan: using cultural heritage application and performance facilities as examples

    NASA Astrophysics Data System (ADS)

    Tsai, Li-Fen; Shaw, Jing-Chi; Wang, Pei-Wen; Shih, Meng-Long; Su, Yi-Jing

    2011-10-01

    This study aims to probe into customers' online word-of-mouth regarding cultural heritage applications and performance facilities in Cultural and Creative Industries. Findings demonstrate that, regarding online word-of-mouth for art museums, museums, and art villages, items valued by customers are design aesthetics of displays and collections, educational functions, and environments and landscapes. The percentages are 10.102%, 11.208% and 11.44%, respectively. In addition, cultural heritage applications and performance facility industries in Taiwan are highly valued in online word-of-mouth.

  16. Ultra violet disinfection: A 3-year history

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tubesing, R.R.; Lindeke, D.R.

    1998-07-01

    The Stillwater Wastewater Treatment Facility is one of nine wastewater treatment facilities operated by the Metropolitan Council Environmental Services in the Minneapolis-St. Paul Metropolitan Area. The facility services the cities of Stillwater, Oak Park Heights, and Bayport. In 1993, an ultra violet disinfection facility began operation to provide the disinfection for the Facility. This presentation discusses the reasons for using ultra violet disinfection in lieu of chlorination/dechlorination facilities, the operating performance, and operating cost factors.

  17. 30 CFR 56.6800 - Storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Storage facilities. 56.6800 Section 56.6800... § 56.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another facility, or moved at...

  18. 30 CFR 56.6800 - Storage facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Storage facilities. 56.6800 Section 56.6800... § 56.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another facility, or moved at...

  19. 30 CFR 56.6800 - Storage facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Storage facilities. 56.6800 Section 56.6800... § 56.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another facility, or moved at...

  20. 30 CFR 56.6800 - Storage facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Storage facilities. 56.6800 Section 56.6800... § 56.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another facility, or moved at...

  1. 30 CFR 56.6800 - Storage facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Storage facilities. 56.6800 Section 56.6800... § 56.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another facility, or moved at...

  2. 40 CFR 60.710 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Magnetic Tape Coating Facilities § 60.710 Applicability and designation of affected facility... than 370 m3 of solvent for the manufacture of magnetic tape per calendar year is subject only to the... of magnetic tape equals or exceeds these amounts in any calendar year, the facility is subject to...

  3. 40 CFR 60.710 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Performance for Magnetic Tape Coating Facilities § 60.710 Applicability and designation of affected facility... than 370 m3 of solvent for the manufacture of magnetic tape per calendar year is subject only to the... of magnetic tape equals or exceeds these amounts in any calendar year, the facility is subject to...

  4. Performance Predictions for Proposed ILS Facilities at St. Louis Municipal Airport

    DOT National Transportation Integrated Search

    1978-01-01

    The results of computer simulations of performance of proposed ILS facilities on Runway 12L/30R at St. Louis Municipal Airport (Lambert Field) are reported. These simulations indicate that an existing industrial complex located near the runway is com...

  5. Analysis of EPA's Federal Facilities Restoration and Reuse Office (FFRRO) Regional Program Performance: Fiscal Years 2005-2011

    EPA Pesticide Factsheets

    This is a summary report of a series of analyses of the Federal Facilities Restoration and Reuse Office (FFRRO) regional programs' performance in meeting their annual targets for the last seven years (2005-2011).

  6. Hazardous Waste Cleanup: Momentive Performance Materials Silicones, LLC in Waterford, New York

    EPA Pesticide Factsheets

    Momentive Performance Materials Silicones, LLC (MPM Silicones, LLC) owns and operates a large silicone manufacturing facility at 260 Hudson River Road, Waterford on an 800-acre site in the Town of Waterford, Saratoga County, New York. The facility is

  7. 40 CFR 60.180 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Lead Smelters § 60.180 Applicability and designation of affected facility. (a) The...: sintering machine, sintering machine discharge end, blast furnace, dross reverberatory furnace, electric...

  8. 40 CFR 60.180 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Lead Smelters § 60.180 Applicability and designation of affected facility. (a) The...: sintering machine, sintering machine discharge end, blast furnace, dross reverberatory furnace, electric...

  9. Network Performance Evaluation Model for assessing the impacts of high-occupancy vehicle facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Janson, B.N.; Zozaya-Gorostiza, C.; Southworth, F.

    1986-09-01

    A model to assess the impacts of major high-occupancy vehicle (HOV) facilities on regional levels of energy consumption and vehicle air pollution emissions in urban aeas is developed and applied. This model can be used to forecast and compare the impacts of alternative HOV facility design and operation plans on traffic patterns, travel costs, model choice, travel demand, energy consumption and vehicle emissions. The model is designed to show differences in the overall impacts of alternative HOV facility types, locations and operation plans rather than to serve as a tool for detailed engineering design and traffic planning studies. The Networkmore » Performance Evaluation Model (NETPEM) combines several urban transportation planning models within a multi-modal network equilibrium framework including modules with which to define the type, location and use policy of the HOV facility to be tested, and to assess the impacts of this facility.« less

  10. Engineering directorate technical facilities catalog

    NASA Technical Reports Server (NTRS)

    Maloy, Joseph E.

    1993-01-01

    The Engineering Directorate Technical Facilities Catalog is designed to provide an overview of the technical facilities available within the Engineering Directorate at the National Aeronautics and Space Administration (NASA), Lyndon B. Johnson Space Center (JSC) in Houston, Texas. The combined capabilities of these engineering facilities are essential elements of overall JSC capabilities required to manage and perform major NASA engineering programs. The facilities are grouped in the text by chapter according to the JSC division responsible for operation of the facility. This catalog updates the facility descriptions for the JSC Engineering Directorate Technical Facilities Catalog, JSC 19295 (August 1989), and supersedes the Engineering Directorate, Principle test and Development Facilities, JSC, 19962 (November 1984).

  11. EPA Facility Registry System (FRS): NEPT

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link to the National Environmental Performance Track (NEPT) Program dataset. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs

  12. Development of a calibration equipment for spectrometer qualification

    NASA Astrophysics Data System (ADS)

    Michel, C.; Borguet, B.; Boueé, A.; Blain, P.; Deep, A.; Moreau, V.; François, M.; Maresi, L.; Myszkowiak, A.; Taccola, M.; Versluys, J.; Stockman, Y.

    2017-09-01

    With the development of new spectrometer concepts, it is required to adapt the calibration facilities to characterize correctly their performances. These spectro-imaging performances are mainly Modulation Transfer Function, spectral response, resolution and registration; polarization, straylight and radiometric calibration. The challenge of this calibration development is to achieve better performance than the item under test using mostly standard items. Because only the subsystem spectrometer needs to be calibrated, the calibration facility needs to simulate the geometrical "behaviours" of the imaging system. A trade-off study indicates that no commercial devices are able to fulfil completely all the requirements so that it was necessary to opt for an in home telecentric achromatic design. The proposed concept is based on an Offner design. This allows mainly to use simple spherical mirrors and to cover the spectral range. The spectral range is covered with a monochromator. Because of the large number of parameters to record the calibration facility is fully automatized. The performances of the calibration system have been verified by analysis and experimentally. Results achieved recently on a free-form grating Offner spectrometer demonstrate the capacities of this new calibration facility. In this paper, a full calibration facility is described, developed specifically for a new free-form spectro-imager.

  13. Survey of aircraft icing simulation test facilities in North America

    NASA Technical Reports Server (NTRS)

    Olsen, W.

    1981-01-01

    A survey was made of the aircraft icing simulation facilities in North America: there are 12 wind tunnels, 28 engine test facilities, 6 aircraft tankers and 14 low velocity facilities, that perform aircraft icing tests full or part time. The location and size of the facility, its speed and temperature range, icing cloud parameters, and the technical person to contact are surveyed. Results are presented in tabular form. The capabilities of each facility were estimated by its technical contact person. The adequacy of these facilities for various types of icing tests is discussed.

  14. Pathways to high and low performance: factors differentiating primary care facilities under performance-based financing in Nigeria

    PubMed Central

    Mabuchi, Shunsuke; Sesan, Temilade; Bennett, Sara C

    2018-01-01

    Abstract The determinants of primary health facility performance in developing countries have not been well studied. One of the most under-researched areas is health facility management. This study investigated health facilities under the pilot performance-based financing (PBF) scheme in Nigeria, and aimed to understand which factors differentiated primary health care centres (PHCCs) which had performed well, vs those which had not, with a focus on health facility management practices. We used a multiple case study where we compared two high-performing PHCCs and two low-performing PHCCs for each of the two PBF target states. Two teams of two trained local researchers spent 1 week at each PHCC and collected semi-structured interview, observation and documentary data. Data from interviews were transcribed, translated and coded using a framework approach. The data for each PHCC were synthesized to understand dynamic interactions of different elements in each case. We then compared the characteristics of high and low performers. The areas in which critical differences between high and low-performers emerged were: community engagement and support; and performance and staff management. We also found that (i) contextual and health system factors particularly staffing, access and competition with other providers; (ii) health centre management including community engagement, performance management and staff management; and (iii) community leader support interacted and drove performance improvement among the PHCCs. Among them, we found that good health centre management can overcome some contextual and health system barriers and enhance community leader support. This study findings suggest a strong need to select capable and motivated health centre managers, provide long-term coaching in managerial skills, and motivate them to improve their practices. The study also highlights the need to position engagement with community leaders as a key management practice and a central element of interventions to improve PHCC performance. PMID:29077844

  15. Development and Validation of Pathogen Environmental Monitoring Programs for Small Cheese Processing Facilities.

    PubMed

    Beno, Sarah M; Stasiewicz, Matthew J; Andrus, Alexis D; Ralyea, Robert D; Kent, David J; Martin, Nicole H; Wiedmann, Martin; Boor, Kathryn J

    2016-12-01

    Pathogen environmental monitoring programs (EMPs) are essential for food processing facilities of all sizes that produce ready-to-eat food products exposed to the processing environment. We developed, implemented, and evaluated EMPs targeting Listeria spp. and Salmonella in nine small cheese processing facilities, including seven farmstead facilities. Individual EMPs with monthly sample collection protocols were designed specifically for each facility. Salmonella was detected in only one facility, with likely introduction from the adjacent farm indicated by pulsed-field gel electrophoresis data. Listeria spp. were isolated from all nine facilities during routine sampling. The overall Listeria spp. (other than Listeria monocytogenes ) and L. monocytogenes prevalences in the 4,430 environmental samples collected were 6.03 and 1.35%, respectively. Molecular characterization and subtyping data suggested persistence of a given Listeria spp. strain in seven facilities and persistence of L. monocytogenes in four facilities. To assess routine sampling plans, validation sampling for Listeria spp. was performed in seven facilities after at least 6 months of routine sampling. This validation sampling was performed by independent individuals and included collection of 50 to 150 samples per facility, based on statistical sample size calculations. Two of the facilities had a significantly higher frequency of detection of Listeria spp. during the validation sampling than during routine sampling, whereas two other facilities had significantly lower frequencies of detection. This study provides a model for a science- and statistics-based approach to developing and validating pathogen EMPs.

  16. Experimental investigation of nozzle/plume aerodynamics at hypersonic speeds

    NASA Technical Reports Server (NTRS)

    Bogdanoff, David W.; Cambier, Jean-Luc; Papadopoulos, Perikles

    1994-01-01

    Much of the work involved the Ames 16-Inch Shock Tunnel facility. The facility was reactivated and upgraded, a data acquisition system was configured and upgraded several times, several facility calibrations were performed and test entries with a wedge model with hydrogen injection and a full scramjet combustor model, with hydrogen injection, were performed. Extensive CFD modeling of the flow in the facility was done. This includes modeling of the unsteady flow in the driver and driven tubes and steady flow modeling of the nozzle flow. Other modeling efforts include simulations of non-equilibrium flows and turbulence, plasmas, light gas guns and the use of non-ideal gas equations of state. New experimental techniques to improve the performance of gas guns, shock tubes and tunnels and scramjet combustors were conceived and studied computationally. Ways to improve scramjet engine performance using steady and pulsed detonation waves were also studied computationally. A number of studies were performed on the operation of the ram accelerator, including investigations of in-tube gasdynamic heating and the use of high explosives to raise the velocity capability of the device.

  17. Do Recipients of an Association-Sponsored Quality Award Program Experience Better Quality Outcomes Compared With Other Nursing Facilities Across the United States?

    PubMed

    Castle, Nicholas; Olson, Doug; Shah, Urvi; Hansen, Kevin

    2016-09-01

    This study explores the relationship between recipients of an association-sponsored Quality Award Program and select measures of quality in U.S. nursing facilities, examined both cross-sectionally and over time. Data used came from Quality Award Program recipients over 9 years (2003-2011) and a set of quality indicators from the Online Survey Certification and Reporting (OSCAR) database. These data were analyzed using a variety of multivariate regression techniques. Cross-sectionally, the award recipients demonstrated higher performance on most of the quality indicators, compared with both the broader field of nursing facilities and also a more stringent comparison group of facilities. Comparing quality from the 4 years before the award was received to the 4 years after the award, the majority of quality indicators demonstrated improvement in those facilities receiving an award. These results indicate that, in general, the nursing facilities that participate in and receive the Silver or Gold American Health Care Association (AHCA) and National Center for Assisted Living (NCAL) National Quality Award perform at a higher level of quality for residents and sustain that heightened performance over a period of time.

  18. A Survey of Research Performed at NASA Langley Research Center's Impact Dynamics Research Facility

    NASA Technical Reports Server (NTRS)

    Jackson, K. E.; Fasanella, E. L.

    2003-01-01

    The Impact Dynamics Research Facility (IDRF) is a 240-ft-high gantry structure located at NASA Langley Research Center in Hampton, Virginia. The facility was originally built in 1963 as a lunar landing simulator, allowing the Apollo astronauts to practice lunar landings under realistic conditions. The IDRF was designated a National Historic Landmark in 1985 based on its significant contributions to the Apollo Program. In 1972, the facility was converted to a full-scale crash test facility for light aircraft and rotorcraft. Since that time, the IDRF has been used to perform a wide variety of impact tests on full-scale aircraft and structural components in support of the General Aviation (GA) aircraft industry, the US Department of Defense, the rotorcraft industry, and NASA in-house aeronautics and space research programs. The objective of this paper is to describe most of the major full-scale crash test programs that were performed at this unique, world-class facility since 1974. The past research is divided into six sub-topics: the civil GA aircraft test program, transport aircraft test program, military test programs, space test programs, basic research, and crash modeling and simulation.

  19. Using a quality improvement model to enhance providers' performance in maternal and newborn health care: a post-only intervention and comparison design.

    PubMed

    Ayalew, Firew; Eyassu, Gizachew; Seyoum, Negash; van Roosmalen, Jos; Bazant, Eva; Kim, Young Mi; Tekleberhan, Alemnesh; Gibson, Hannah; Daniel, Ephrem; Stekelenburg, Jelle

    2017-04-12

    The Standards Based Management and Recognition (SBM-R © ) approach to quality improvement has been implemented in Ethiopia to strengthen routine maternal and newborn health (MNH) services. This evaluation assessed the effect of the intervention on MNH providers' performance of routine antenatal care (ANC), uncomplicated labor and delivery and immediate postnatal care (PNC) services. A post-only evaluation design was conducted at three hospitals and eight health centers implementing SBM-R and the same number of comparison health facilities. Structured checklists were used to observe MNH providers' performance on ANC (236 provider-client interactions), uncomplicated labor and delivery (226 provider-client interactions), and immediate PNC services in the six hours after delivery (232 provider-client interactions); observations were divided equally between intervention and comparison groups. Main outcomes were provider performance scores, calculated as the percentage of essential tasks in each service area completed by providers. Multilevel analysis was used to calculate adjusted mean percentage performance scores and standard errors to compare intervention and comparison groups. There was no statistically significant difference between intervention and comparison facilities in overall mean performance scores for ANC services (63.4% at intervention facilities versus 61.0% at comparison facilities, p = 0.650) or in any specific ANC skill area. MNH providers' overall mean performance score for uncomplicated labor and delivery care was 11.9 percentage points higher in the intervention than in the comparison group (77.5% versus 65.6%; p = 0.002). Overall mean performance scores for immediate PNC were 22.2 percentage points higher at intervention than at comparison facilities (72.8% versus 50.6%; p = 0.001); and there was a significant difference of 22 percentage points between intervention and comparison facilities for each PNC skill area: care for the newborn and health check for the mother. The SBM-R quality improvement intervention made a significant positive impact on MNH providers' performance during labor and delivery and immediate PNC services, but not during ANC services. Scaling up the intervention to other facilities and regions may increase the availability of good quality MNH services across Ethiopia. The findings will also guide implementation of the government's five-year (2015-2020) health sector transformation plan and health care quality strategies needed to meet the country's MNH goals.

  20. 40 CFR 265.174 - Inspections.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Management of Containers § 265.174 Inspections. At least weekly, the owner or operator must inspect areas where containers are stored, except for Performance Track member facilities, that must conduct..., the Performance Track member facility must follow the procedures described in § 265.15(b)(5) of this...

  1. 40 CFR 265.174 - Inspections.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Management of Containers § 265.174 Inspections. At least weekly, the owner or operator must inspect areas where containers are stored, except for Performance Track member facilities, that must conduct..., the Performance Track member facility must follow the procedures described in § 265.15(b)(5) of this...

  2. 40 CFR 265.174 - Inspections.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Management of Containers § 265.174 Inspections. At least weekly, the owner or operator must inspect areas where containers are stored, except for Performance Track member facilities, that must conduct..., the Performance Track member facility must follow the procedures described in § 265.15(b)(5) of this...

  3. 40 CFR 265.174 - Inspections.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Management of Containers § 265.174 Inspections. At least weekly, the owner or operator must inspect areas where containers are stored, except for Performance Track member facilities, that must conduct..., the Performance Track member facility must follow the procedures described in § 265.15(b)(5) of this...

  4. 40 CFR 265.174 - Inspections.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Management of Containers § 265.174 Inspections. At least weekly, the owner or operator must inspect areas where containers are stored, except for Performance Track member facilities, that must conduct..., the Performance Track member facility must follow the procedures described in § 265.15(b)(5) of this...

  5. A facility for testing 10 to 100-kWe space power reactors

    NASA Astrophysics Data System (ADS)

    Carlson, William F.; Bitten, Ernest J.

    1993-01-01

    This paper describes an existing facility that could be used in a cost-effective manner to test space power reactors in the 10 to 100-kWe range before launch. The facility has been designed to conduct full power tests of 100-kWe SP-100 reactor systems and already has the structural features that would be required for lower power testing. The paper describes a reasonable scenario starting with the acceptance at the test site of the unfueled reactor assembly and the separately shipped nuclear fuel. After fueling the reactor and installing it in the facility, cold critical tests are performed, and the reactor is then shipped to the launch site. The availability of this facility represents a cost-effective means of performing the required prelaunch test program.

  6. Developing a NASA strategy for the verification of large space telescope observatories

    NASA Astrophysics Data System (ADS)

    Crooke, Julie A.; Gunderson, Johanna A.; Hagopian, John G.; Levine, Marie

    2006-06-01

    In July 2005, the Office of Program Analysis and Evaluation (PA&E) at NASA Headquarters was directed to develop a strategy for verification of the performance of large space telescope observatories, which occurs predominantly in a thermal vacuum test facility. A mission model of the expected astronomical observatory missions over the next 20 years was identified along with performance, facility and resource requirements. Ground testing versus alternatives was analyzed to determine the pros, cons and break points in the verification process. Existing facilities and their capabilities were examined across NASA, industry and other government agencies as well as the future demand for these facilities across NASA's Mission Directorates. Options were developed to meet the full suite of mission verification requirements, and performance, cost, risk and other analyses were performed. Findings and recommendations from the study were presented to the NASA Administrator and the NASA Strategic Management Council (SMC) in February 2006. This paper details the analysis, results, and findings from this study.

  7. Environmental scanning as a moderator of strategy-performance relationships: an empirical analysis of physical therapy facilities.

    PubMed

    Davis, Mark A; Miles, Grant; McDowell, William C

    2008-05-01

    To date, strategic management research in health care is largely confined to the acute care sector of the industry. This research examines the linkages among environmental scanning, competitive strategy and performance in physical therapy facilities. Nontrivial differences between acute and subacute care firms suggest the role of environmental scanning may change in non-acute care settings. Consistent with previous research, these results indicate that the frequency of internal and external scanning is related to the strategic orientation of physical therapy facilities. Contrary to the expectations, broader scope of scanning is positively related to an increasing market-focused and increasing efficiency strategic orientation. A key objective of the research is to test the impact of strategy/scanning alignment on facility performance. These findings support predictions on the moderating role of scanning activities in the strategy-performance relationship. However, a paradoxical pattern of results has possible implications for clinician managers in subacute care settings as well as the interpretation of scanning activities.

  8. Environmental Health Practice: Statistically Based Performance Measurement

    PubMed Central

    Enander, Richard T.; Gagnon, Ronald N.; Hanumara, R. Choudary; Park, Eugene; Armstrong, Thomas; Gute, David M.

    2007-01-01

    Objectives. State environmental and health protection agencies have traditionally relied on a facility-by-facility inspection-enforcement paradigm to achieve compliance with government regulations. We evaluated the effectiveness of a new approach that uses a self-certification random sampling design. Methods. Comprehensive environmental and occupational health data from a 3-year statewide industry self-certification initiative were collected from representative automotive refinishing facilities located in Rhode Island. Statistical comparisons between baseline and postintervention data facilitated a quantitative evaluation of statewide performance. Results. The analysis of field data collected from 82 randomly selected automotive refinishing facilities showed statistically significant improvements (P<.05, Fisher exact test) in 4 major performance categories: occupational health and safety, air pollution control, hazardous waste management, and wastewater discharge. Statistical significance was also shown when a modified Bonferroni adjustment for multiple comparisons was performed. Conclusions. Our findings suggest that the new self-certification approach to environmental and worker protection is effective and can be used as an adjunct to further enhance state and federal enforcement programs. PMID:17267709

  9. Clinical Practice Guideline Implementation Strategy Patterns in Veterans Affairs Primary Care Clinics

    PubMed Central

    Hysong, Sylvia J; Best, Richard G; Pugh, Jacqueline A

    2007-01-01

    Background The Department of Veterans Affairs (VA) mandated the system-wide implementation of clinical practice guidelines (CPGs) in the mid-1990s, arming all facilities with basic resources to facilitate implementation; despite this resource allocation, significant variability still exists across VA facilities in implementation success. Objective This study compares CPG implementation strategy patterns used by high and low performing primary care clinics in the VA. Research Design Descriptive, cross-sectional study of a purposeful sample of six Veterans Affairs Medical Centers (VAMCs) with high and low performance on six CPGs. Subjects One hundred and two employees (management, quality improvement, clinic personnel) involved with guideline implementation at each VAMC primary care clinic. Measures Participants reported specific strategies used by their facility to implement guidelines in 1-hour semi-structured interviews. Facilities were classified as high or low performers based on their guideline adherence scores calculated through independently conducted chart reviews. Findings High performing facilities (HPFs) (a) invested significantly in the implementation of the electronic medical record and locally adapting it to provider needs, (b) invested dedicated resources to guideline-related initiatives, and (c) exhibited a clear direction in their strategy choices. Low performing facilities exhibited (a) earlier stages of development for their electronic medical record, (b) reliance on preexisting resources for guideline implementation, with little local adaptation, and (c) no clear direction in their strategy choices. Conclusion A multifaceted, yet targeted, strategic approach to guideline implementation emphasizing dedicated resources and local adaptation may result in more successful implementation and higher guideline adherence than relying on standardized resources and taxing preexisting channels. PMID:17355583

  10. Shock wave facilities at Pulter Laboratory of SRI international

    NASA Astrophysics Data System (ADS)

    Murri, W. J.

    1982-04-01

    Shock wave research in the Poulter Laboratory covers two broad areas: dynamic material response and dynamic structural response. Workers in both areas use common facilities. The Laboratory has several guns and the facilities to perform various types of high explosive loading experiments. The use of these facilities and experimental techniques is illustrated with examples from research projects.

  11. Performance needs assessment of maternal and newborn health service delivery in urban and rural areas of Osun State, South-West, Nigeria.

    PubMed

    Esan, Oluwaseun T; Fatusi, Adesegun O

    2014-06-01

    The study aimed to determine performance and compare gaps in maternal and newborn health (MNH) services in urban and rural areas of Osun State, Nigeria, to inform decisions for improved services. This study involved 14 urban and 10 rural-based randomly selected PHC facilities. Using a Performance Needs Assessment framework, desired performances were determined by key stakeholders and actual performances measured by conducting facility survey. Questionnaire interview of 143 health workers and 153 antenatal clients were done. Performance gaps were determined for the urban and rural areas and compared using Chi-square tests with SPSS version 17. PHC facilities and health workers in Osun State, Nigeria, were found to have significant gaps in MNH service performance and this was worse in the rural areas. Root cause of most of the performance gaps was poor political will of local government authorities. Improved government commitment to MNH is needful to address most of the gaps.

  12. Hydrologic evaluation methodology for estimating water movement through the unsaturated zone at commercial low-level radioactive waste disposal site

    USGS Publications Warehouse

    Meyer, P.D.; Rockhold, M.L.; Nichols, W.E.; Gee, G.W.

    1996-01-01

    This report identifies key technical issues related to hydrologic assessment of water flow in the unsaturated zone at low-level radioactive waste (LLW) disposal facilities. In addition, a methodology for incorporating these issues in the performance assessment of proposed LLW disposal facilities is identified and evaluated. The issues discussed fall into four areas:Estimating the water balance at a site (i.e., infiltration, runoff, water storage, evapotranspiration, and recharge);Analyzing the hydrologic performance of engineered components of a facility;Evaluating the application of models to the prediction of facility performance; andEstimating the uncertainty in predicted facility performance.An estimate of recharge at a LLW site is important since recharge is a principal factor in controlling the release of contaminants via the groundwater pathway. The most common methods for estimating recharge are discussed in Chapter 2. Many factors affect recharge; the natural recharge at an undisturbed site is not necessarily representative either of the recharge that will occur after the site has been disturbed or of the flow of water into a disposal facility at the site. Factors affecting recharge are discussed in Chapter 2.At many sites engineered components are required for a LLW facility to meet performance requirements. Chapter 3 discusses the use of engineered barriers to control the flow of water in a LLW facility, with a particular emphasis on cover systems. Design options and the potential performance and degradation mechanisms of engineered components are also discussed.Water flow in a LLW disposal facility must be evaluated before construction of the facility. In addition, hydrologic performance must be predicted over a very long time frame. For these reasons, the hydrologic evaluation relies on the use of predictive modeling. In Chapter 4, the evaluation of unsaturated water flow modeling is discussed. A checklist of items is presented to guide the evaluation. Several computer simulation codes that were used in the examples (Chapter 6) are discussed with respect to this checklist. The codes used include HELP, UNSAT-H, and VAM3DCG.To provide a defensible estimate of water flow in a LLW disposal facility, the uncertainty associated with model predictions must be considered. Uncertainty arises because of the highly heterogeneous nature of most subsurface environments and the long time frame required in the analysis. Sources of uncertainty in hydrologic evaluation of the unsaturated zone and several approaches for analysis are discussed in Chapter 5. The methods of analysis discussed include a bounding approach, sensitivity analysis, and Monte Carlo simulation.To illustrate the application of the discussion in Chapters 2 through 5, two examples are presented in Chapter 6. The first example is of a below ground vault located in a humid environment. The second example looks at a shallow land burial facility located in an arid environment. The examples utilize actual site-specific data and realistic facility designs. The two examples illustrate the issues unique to humid and arid sites as well as the issues common to all LLW sites. Strategies for addressing the analytical difficulties arising in any complex hydrologic evaluation of the unsaturated zone are demonstrated.The report concludes with some final observations and recommendations.

  13. Earthquake effects at nuclear reactor facilities: San Fernando earthquake of February 9th, 1971

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard, G.; Ibanez, P.; Matthiesen, F.

    1972-02-01

    The effects of the San Fernando earthquake of February 9, 1971 on 26 reactor facilities located in California, Arizona, and Nevada are reported. The safety performance of the facilities during the earthquake is discussed. (JWR)

  14. Performance of the High-Energy Single-Event Effects Test Facility (SEETF) at Michigan State University's National Superconducting Cyclotron Laboratory (NSCL)

    NASA Technical Reports Server (NTRS)

    Ladbury, R.; Reed, R. A.; Marshall, P. W.; LaBel, K. A.; Anantaraman, R.; Fox, R.; Sanderson, D. P.; Stolz, A.; Yurkon, J.; Zeller, A. F.; hide

    2004-01-01

    The performance of Michigan State University's Single-Event Effects Test Facility (SEETF) during its inaugural runs is evaluated. Beam profiles and other diagnostics are presented, and prospects for future development and testing are discussed.

  15. 40 CFR 60.150 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sewage Treatment Plants § 60.150 Applicability and designation of affected facility. (a) The... (dry basis) produced by municipal sewage treatment plants, or each incinerator that charges more than...

  16. Hospitalizations Among Nursing Home Residents in the Last Year of Life: Nursing Home Characteristics and Variation in Potentially Avoidable Hospitalizations

    PubMed Central

    Xing, Jingping; Mukamel, Dana B.; Temkin-Greener, Helena

    2013-01-01

    Objectives 1) To examine the incidence, variations, and costs in potentially avoidable hospitalizations (PAHs) among nursing home (NH) residents at the end-of-life. 2) To identify the association between NH characteristics and a facility-level quality measure (QM) for PAH. Design Retrospective study. Setting Hospitalizations originating from NHs. Participants Long-term care NH residents who died in 2007. Measurements We constructed a risk-adjusted QM for PAH. Poisson regression model was used to predict the count of PAH given residents’ risk factors. For each facility, the QM was defined as the difference between the observed facility-specific rate (per 1,000 person-years) of PAH (O) and the expected risk-adjusted rate (E). We then fit a logistic regression model with state fixed-effects to examine the association between facility characteristics and the likelihood of having higher than expected rates of PAH (O-E>0). QM values higher than 0 indicate worse than average quality. Results Almost 50% of hospital admissions for NH residents in their last year of life were for potentially avoidable diagnoses, costing Medicare $1billion. Five conditions were responsible for over 80% of PAHs. PAH QM across facilities showed significant variation (mean=11.96; std dev=142.26; range: −399.48-398.09). Chain and hospital-based facilities were more likely to exhibit better performance (O-E<0). Facilities with higher nursing staffing were more likely to have better performance, as did facilities with higher skilled staff ratio, facilities with nurse practitioners/physician assistants, and those with on-site x-ray services. Conclusion Variations in facility-level PAHs suggest that a potential for reducing hospital admissions for these conditions may exist. Presence of modifiable facility characteristics associated with PAH performance provides insights into possible interventions for reducing PAHs at the end-of-life. PMID:24219191

  17. Expanding the Scope of High-Performance Computing Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uram, Thomas D.; Papka, Michael E.

    The high-performance computing centers of the future will expand their roles as service providers, and as the machines scale up, so should the sizes of the communities they serve. National facilities must cultivate their users as much as they focus on operating machines reliably. The authors present five interrelated topic areas that are essential to expanding the value provided to those performing computational science.

  18. Gap analysis: assessing the value perception of consultant pharmacist services and the performance of consultant pharmacists.

    PubMed

    Clark, Thomas R

    2008-09-01

    To understand the importance of services provided by consultant pharmacists and to assess perception of their performance of services. Cross-sectional; nursing facility team. Random e-mail survey of consultant pharmacists; phone survey of team members. 233 consultant pharmacists (practicing in a nursing facility); 540 team members (practicing in a nursing facility, interacting with > or = 1 consultant pharmacist): 120 medical directors, 210 directors of nursing, 210 administrators. Consultant pharmacists, directors of nursing, medical directors, and administrators rating importance/performance of 21 services. Gap between teams' ratings of importance and consultant pharmacists' performance is assessed to categorize services. Importance/performance ranked on five-point scale. Mean scores used for gap analysis to cluster services into four categories. Per combined group, six services categorized as "Keep It Up" (important, good performance), consensus with individual groups, except discrepancy with medical directors, for one service. Six services each categorized as "Improve" (important, large gap) and "Improve Second" (lower importance, large gap), with varied responses by individual groups. Three different services were categorized into "Don't Worry," with consensus within individual groups. Consensus from all groups found 5 of 21 services are important and performed well by consultant pharmacists, indicating to maintain performance of services. For three services, consultant pharmacists do not need to worry about their performance. Thirteen services require improvement in consultant pharmacists' performance; various groups differ on extent of improvement needed. Results can serve as benchmark comparisons with results obtained by consultant pharmacists in their own facilities.

  19. Facilities Performance Indicators Report, 2006-07

    ERIC Educational Resources Information Center

    Glazner, Steve, Ed.

    2008-01-01

    The "Facilities Performance Indicators Survey" ("FPI") supersedes and builds upon the two major surveys APPA conducted in the past: the Comparative Costs and Staffing (CCAS) survey and the Strategic Assessment Model (SAM). The "FPI" covers all the materials collected in CCAS and SAM, along with some select new data points and improved survey…

  20. Best Practices Manual, 2002 Edition.

    ERIC Educational Resources Information Center

    Collaborative for High Performance Schools, CA.

    The goal of this manual is to create a new generation of high performance school facilities in California. The focus is on public schools and levels K-12, althoughmany of the design principals apply to private schools and higher education facilities as well. High performance schools are healthy, comfortable, energy efficient, resource efficient,…

  1. 40 CFR 408.165 - Standards of performance for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Hand-Butchered Salmon Processing Subcategory § 408.165 Standards of performance for new sources. (a... this subpart: (1) Any hand-butchered salmon processing facility located in population or processing... salmon processing facility not covered under § 408.165(a)(1) shall meet the following limitations: No...

  2. 40 CFR 408.165 - Standards of performance for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Hand-Butchered Salmon Processing Subcategory § 408.165 Standards of performance for new sources. (a... this subpart: (1) Any hand-butchered salmon processing facility located in population or processing... salmon processing facility not covered under § 408.165(a)(1) shall meet the following limitations: No...

  3. The U.S. Geological Survey's TRIGA® reactor

    USGS Publications Warehouse

    DeBey, Timothy M.; Roy, Brycen R.; Brady, Sally R.

    2012-01-01

    The U.S. Geological Survey (USGS) operates a low-enriched uranium-fueled, pool-type reactor located at the Federal Center in Denver, Colorado. The mission of the Geological Survey TRIGA® Reactor (GSTR) is to support USGS science by providing information on geologic, plant, and animal specimens to advance methods and techniques unique to nuclear reactors. The reactor facility is supported by programs across the USGS and is organizationally under the Associate Director for Energy and Minerals, and Environmental Health. The GSTR is the only facility in the United States capable of performing automated delayed neutron analyses for detecting fissile and fissionable isotopes. Samples from around the world are submitted to the USGS for analysis using the reactor facility. Qualitative and quantitative elemental analyses, spatial elemental analyses, and geochronology are performed. Few research reactor facilities in the United States are equipped to handle the large number of samples processed at the GSTR. Historically, more than 450,000 sample irradiations have been performed at the USGS facility. Providing impartial scientific information to resource managers, planners, and other interested parties throughout the world is an integral part of the research effort of the USGS.

  4. Cycle O (CY 1991) NLS trade studies and analyses, book 2. Part 1: Avionics and systems

    NASA Technical Reports Server (NTRS)

    Harris, Richard; Kirkland, Zach

    1992-01-01

    An assessment was conducted to determine the maximum LH2 tank stretch capability based on the constraints of the manufacturing, tooling and facilities at the Michoud Assembly Facility in New Orleans, Louisiana. The maximum tank stretch was determined to be 5 ft. with minor or no modifications, a stretch of 11 ft. with some possible facility modifications and beyond 11 ft. significant new facilities are required. A cost analysis was performed to evaluate the impacts for various stretch lengths. Tasks that were defined to perform trades and studies regarding the best approach to meet requirements for the National Launch System Avionics are also discussed.

  5. Medical Isotope Production Analyses In KIPT Neutron Source Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talamo, Alberto; Gohar, Yousry

    Medical isotope production analyses in Kharkov Institute of Physics and Technology (KIPT) neutron source facility were performed to include the details of the irradiation cassette and the self-shielding effect. An updated detailed model of the facility was used for the analyses. The facility consists of an accelerator-driven system (ADS), which has a subcritical assembly using low-enriched uranium fuel elements with a beryllium-graphite reflector. The beryllium assemblies of the reflector have the same outer geometry as the fuel elements, which permits loading the subcritical assembly with different number of fuel elements without impacting the reflector performance. The subcritical assembly is drivenmore » by an external neutron source generated from the interaction of 100-kW electron beam with a tungsten target. The facility construction was completed at the end of 2015, and it is planned to start the operation during the year of 2016. It is the first ADS in the world, which has a coolant system for removing the generated fission power. Argonne National Laboratory has developed the design concept and performed extensive design analyses for the facility including its utilization for the production of different radioactive medical isotopes. 99Mo is the parent isotope of 99mTc, which is the most commonly used medical radioactive isotope. Detailed analyses were performed to define the optimal sample irradiation location and the generated activity, for several radioactive medical isotopes, as a function of the irradiation time.« less

  6. An inventory of aeronautical ground research facilities. Volume 4: Engineering flight simulation facilities

    NASA Technical Reports Server (NTRS)

    Pirrello, C. J.; Hardin, R. D.; Capelluro, L. P.; Harrison, W. D.

    1971-01-01

    The general purpose capabilities of government and industry in the area of real time engineering flight simulation are discussed. The information covers computer equipment, visual systems, crew stations, and motion systems, along with brief statements of facility capabilities. Facility construction and typical operational costs are included where available. The facilities provide for economical and safe solutions to vehicle design, performance, control, and flying qualities problems of manned and unmanned flight systems.

  7. Performance of the Spacecraft Propulsion Research Facility During Altitude Firing Tests of the Delta 3 Upper Stage

    NASA Technical Reports Server (NTRS)

    Meyer, Michael L.; Dickens, Kevin W.; Skaff, Tony F.; Cmar, Mark D.; VanMeter, Matthew J.; Haberbusch, Mark S.

    1998-01-01

    The Spacecraft Propulsion Research Facility at the NASA Lewis Research Center's Plum Brook Station was reactivated in order to conduct flight simulation ground tests of the Delta 3 cryogenic upper stage. The tests were a cooperative effort between The Boeing Company, Pratt and Whitney, and NASA. They included demonstration of tanking and detanking of liquid hydrogen, liquid oxygen and helium pressurant gas as well as 12 engine firings simulating first, second, and third burns at altitude conditions. A key to the success of these tests was the performance of the primary facility systems and their interfaces with the vehicle. These systems included the structural support of the vehicle, propellant supplies, data acquisition, facility control systems, and the altitude exhaust system. While the facility connections to the vehicle umbilical panel simulated the performance of the launch pad systems, additional purge and electrical connections were also required which were unique to ground testing of the vehicle. The altitude exhaust system permitted an approximate simulation of the boost-phase pressure profile by rapidly pumping the test chamber from 13 psia to 0.5 psia as well as maintaining altitude conditions during extended steady-state firings. The performance of the steam driven ejector exhaust system has been correlated with variations in cooling water temperature during these tests. This correlation and comparisons to limited data available from Centaur tests conducted in the facility from 1969-1971 provided insight into optimizing the operation of the exhaust system for future tests. Overall, the facility proved to be robust and flexible for vehicle space simulation engine firings and enabled all test objectives to be successfully completed within the planned schedule.

  8. A Summary of DOD-Sponsored Research Performed at NASA Langley's Impact Dynamics Research Facility

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Boitnott, Richard L.; Fasanella, Edwin L.; Jones, Lisa E.; Lyle, Karen H.

    2004-01-01

    The Impact Dynamics Research Facility (IDRF) is a 240-ft.-high gantry structure located at NASA Langley Research Center in Hampton, Virginia. The IDRF was originally built in the early 1960's for use as a Lunar Landing Research Facility. As such, the facility was configured to simulate the reduced gravitational environment of the Moon, allowing the Apollo astronauts to practice lunar landings under realistic conditions. In 1985, the IDRF was designated a National Historic Landmark based on its significant contributions to the Apollo Moon Landing Program. In the early 1970's the facility was converted into its current configuration as a full-scale crash test facility for light aircraft and rotorcraft. Since that time, the IDRF has been used to perform a wide variety of impact tests on full-scale aircraft, airframe components, and space vehicles in support of the General Aviation (GA) aircraft industry, the U.S. Department of Defense (DOD), the rotorcraft industry, and the NASA Space program. The objectives of this paper are twofold: to describe the IDRF facility and its unique capabilities for conducting structural impact testing, and to summarize the impact tests performed at the IDRF in support of the DOD. These tests cover a time period of roughly 2 1/2 decades, beginning in 1975 with the full-scale crash test of a CH-47 Chinook helicopter, and ending in 1999 with the external fuel system qualification test of a UH-60 Black Hawk helicopter. NASA officially closed the IDRF in September 2003; consequently, it is important to document the past contributions made in improved human survivability and impact tolerance through DOD-sponsored research performed at the IDRF.

  9. Assessment of air velocity sensors for use in animal produciton facilities

    USDA-ARS?s Scientific Manuscript database

    Ventilation is an integral part of thermal environment control in animal production facilities. Accurately measuring the air velocity distribution within these facilities is cumbersome using the traverse method and a distributed velocity measurement system would reduce the time necessary to perform ...

  10. Sound field diffusivity in NASA Langley Research Center hardwalled acoustic facilities

    NASA Technical Reports Server (NTRS)

    Mcgary, M. C.

    1982-01-01

    Cross correlation measurements were performed to determine the quality of the sound fields in the ANRL reverberation room and the ANRL transmission loss facility. The results indicate the level of sound field diffuseness which may be attained in these hardwalled acoustic facilities.

  11. Analyses in support of risk-informed natural gas vehicle maintenance facility codes and standards :

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekoto, Isaac W.; Blaylock, Myra L.; LaFleur, Angela Christine

    2014-03-01

    Safety standards development for maintenance facilities of liquid and compressed gas fueled large-scale vehicles is required to ensure proper facility design and operation envelopes. Standard development organizations are utilizing risk-informed concepts to develop natural gas vehicle (NGV) codes and standards so that maintenance facilities meet acceptable risk levels. The present report summarizes Phase I work for existing NGV repair facility code requirements and highlights inconsistencies that need quantitative analysis into their effectiveness. A Hazardous and Operability study was performed to identify key scenarios of interest. Finally, scenario analyses were performed using detailed simulations and modeling to estimate the overpressure hazardsmore » from HAZOP defined scenarios. The results from Phase I will be used to identify significant risk contributors at NGV maintenance facilities, and are expected to form the basis for follow-on quantitative risk analysis work to address specific code requirements and identify effective accident prevention and mitigation strategies.« less

  12. Alignment system for SGII-Up laser facility

    NASA Astrophysics Data System (ADS)

    Gao, Yanqi; Cui, Yong; Li, Hong; Gong, Lei; Lin, Qiang; Liu, Daizhong; Zhu, Baoqiang; Ma, Weixin; Zhu, Jian; Lin, Zunqi

    2018-03-01

    The SGII-Up laser facility in Shanghai is one of the most important high-power laser facilities in China. It is designed to obtain 24 kJ (3ω) of energy with a square pulse of 3 ns using eight laser beams (two bundles). To satisfy the requirements for the safety, efficiency, and quality, an alignment system is developed for this facility. This alignment system can perform automatic alignment of the preamplifier system, main amplifier system, and harmonic conversion system within 30 min before every shot during the routine operation of the facility. In this article, an overview of the alignment system is first presented. Then, its alignment characteristics are discussed, along with the alignment process. Finally, experimental results, including the alignment results and the facility performance, are reported. The results show that the far-field beam pointing alignment accuracy is better than 3 μrad, and the alignment error of the near-field beam centering is no larger than 1 mm. These satisfy the design requirements very well.

  13. Defocusing beam line design for an irradiation facility at the TAEA SANAEM Proton Accelerator Facility

    NASA Astrophysics Data System (ADS)

    Gencer, A.; Demirköz, B.; Efthymiopoulos, I.; Yiğitoğlu, M.

    2016-07-01

    Electronic components must be tested to ensure reliable performance in high radiation environments such as Hi-Limu LHC and space. We propose a defocusing beam line to perform proton irradiation tests in Turkey. The Turkish Atomic Energy Authority SANAEM Proton Accelerator Facility was inaugurated in May 2012 for radioisotope production. The facility has also an R&D room for research purposes. The accelerator produces protons with 30 MeV kinetic energy and the beam current is variable between 10 μA and 1.2 mA. The beam kinetic energy is suitable for irradiation tests, however the beam current is high and therefore the flux must be lowered. We plan to build a defocusing beam line (DBL) in order to enlarge the beam size, reduce the flux to match the required specifications for the irradiation tests. Current design includes the beam transport and the final focusing magnets to blow up the beam. Scattering foils and a collimator is placed for the reduction of the beam flux. The DBL is designed to provide fluxes between 107 p /cm2 / s and 109 p /cm2 / s for performing irradiation tests in an area of 15.4 cm × 21.5 cm. The facility will be the first irradiation facility of its kind in Turkey.

  14. Ownership conversions and nursing home performance.

    PubMed

    Grabowski, David C; Stevenson, David G

    2008-08-01

    To examine the effects of ownership conversions on nursing home performance. Online Survey, Certification, and Reporting system data from 1993 to 2004, and the Minimum Data Set (MDS) facility reports from 1998 to 2004. Regression specification incorporating facility fixed effects, with terms to identify trends in the pre- and postconversion periods. The annual rate of nursing home conversions almost tripled between 1994 and 2004. Our regression results indicate converting facilities are generally different throughout the pre/postconversion years, suggesting little causal effect of ownership conversions on nursing home performance. Before and after conversion, nursing homes converting from nonprofit to for-profit status generally exhibit deterioration in their performance, while nursing homes converting from for-profit to nonprofit status generally exhibit improvement. Policy makers have expressed concern regarding the implications of ownership conversions for nursing home performance. Our results imply that regulators and policy makers should not only monitor the outcomes of nursing home conversions, but also the targets of these conversions.

  15. Recommended Practice for Pressure Measurements and Calculation of Effective Pumping Speeds During Electric Propulsion Testing

    NASA Technical Reports Server (NTRS)

    Dankanich, John W.; Walker, Mitchell; Swiatek, Michael W.; Yim, John T.

    2013-01-01

    The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Variability between facility-to-facility and more importantly ground-to-flight performance can result in large margins in application or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration, and on-orbit performance. A recommended practice for making pressure measurements, pressure diagnostics, and calculating effective pumping speeds with justification is presented.

  16. Design and Development of E3 Antenna Container,

    DTIC Science & Technology

    1985-09-03

    reinforced with square tubing. The walls and ceiling shall be insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the...ceiling shall be insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the Edgewater Machine & Fabricator’s facility...insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the Edgewater Machine & Fabricator’s facility located at 200 N

  17. Initial outcomes from federally mandated accreditation site surveys of advanced diagnostic imaging facilities performed by the ACR.

    PubMed

    Harvey, H Benjamin; Chow, David; Boston, Marion; Zhao, Jing; Lucey, Leonard; Monticciolo, Debra L

    2014-07-01

    The aim of this study was to evaluate the findings of the first year of validation site surveys performed by the ACR pursuant to new federal accreditation requirements for nonhospital advanced diagnostic imaging (ADI) facilities. In the first year of validation site surveys (November 2012 to November 2013), the ACR surveyed 943 ADI facilities across 21 states. Data were extracted from these site survey reports and analyzed on the basis of the survey outcomes and the frequency and type of deficiencies and recommendations. Follow-up data were obtained from the ACR for facilities deemed noncompliant on the site survey to determine if these facilities adequately took the corrective actions necessary to maintain accreditation. Of the 943 ADI facilities surveyed, 45% (n = 421) were deemed compliant with the ACR accreditation standards, and 55% (n = 522) had one or more deficiencies. Failure to produce the required personnel documentation and absence of mandatory written policies were the two most common causes of deficiencies. Facilities accredited in more modalities tended to fare better in the site surveys, with the number of accredited modalities at a facility negatively associated with the likelihood of a deficiency (P = .007). Of the facilities with deficiencies, 73% (n = 382) took the necessary corrective actions to maintain accreditation, 27% (n = 140) were in the process of taking corrective actions, and no facility has lost accreditation because of an inability to adequately address the deficiencies. Nonbinding recommendations were made to 37% (n = 346) of facilities, and facilities with deficiencies were statistically more likely to receive recommendations (P < .001). Initial site surveys of ADI facilities demonstrated a high proportion of deficient facilities, but no facility has lost accreditation because of an inability to correct these deficiencies. Knowledge of the most common sources of deficiencies and recommendations can assist ACR-accredited ADI facilities in better preparing for validation site surveys, reducing the likelihood of facility noncompliance. Copyright © 2014. Published by Elsevier Inc.

  18. Design philosophy of the Jet Propulsion Laboratory infrared detector test facility

    NASA Technical Reports Server (NTRS)

    Burns, R.; Blessinger, M. A.

    1983-01-01

    To support the development of advanced infrared remote sensing instrumentation using line and area arrays, a test facility has been developed to characterize the detectors. The necessary performance characteristics of the facility were defined by considering current and projected requirements for detector testing. The completed facility provides the desired level of detector testing capability as well as providing ease of human interaction.

  19. Malaria diagnostic capacity in health facilities in Ethiopia

    PubMed Central

    2014-01-01

    Background Accurate early diagnosis and prompt treatment is one of the key strategies to control and prevent malaria in Ethiopia where both Plasmodium falciparum and Plasmodium vivax are sympatric and require different treatment regimens. Microscopy is the standard for malaria diagnosis at the health centres and hospitals whereas rapid diagnostic tests are used at community-level health posts. The current study was designed to assess malaria microscopy capacity of health facilities in Oromia Regional State and Dire Dawa Administrative City, Ethiopia. Methods A descriptive cross-sectional study was conducted from February to April 2011 in 122 health facilities, where health professionals were interviewed using a pre-tested, standardized assessment tool and facilities’ laboratory practices were assessed by direct observation. Results Of the 122 assessed facilities, 104 (85%) were health centres and 18 (15%) were hospitals. Out of 94 health facilities reportedly performing blood films, only 34 (36%) used both thin and thick smears for malaria diagnosis. The quality of stained slides was graded in 66 health facilities as excellent, good and poor quality in 11(17%), 31 (47%) and 24 (36%) respectively. Quality assurance guidelines and malaria microscopy standard operating procedures were found in only 13 (11%) facilities and 12 (10%) had involved in external quality assessment activities, and 32 (26%) had supportive supervision within six months of the survey. Only seven (6%) facilities reported at least one staff’s participation in malaria microscopy refresher training during the previous 12 months. Although most facilities, 96 (79%), had binocular microscopes, only eight (7%) had the necessary reagents and supplies to perform malaria microscopy. Treatment guidelines for malaria were available in only 38 (31%) of the surveyed facilities. Febrile patients with negative malaria laboratory test results were managed with artemether-lumefantrine or chloroquine in 51% (53/104) of assessed health facilities. Conclusions The current study indicated that most of the health facilities had basic infrastructure and equipment to perform malaria laboratory diagnosis but with significant gaps in continuous laboratory supplies and reagents, and lack of training and supportive supervision. Overcoming these gaps will be critical to ensure that malaria laboratory diagnosis is of high-quality for better patient management. PMID:25073561

  20. 40 CFR 265.16 - Personnel training.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Personnel training. 265.16 Section 265... FACILITIES General Facility Standards § 265.16 Personnel training. (a)(1) Facility personnel must successfully complete a program of classroom instruction or on-the-job training that teaches them to perform...

  1. 40 CFR 265.16 - Personnel training.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... successfully complete a program of classroom instruction or on-the-job training that teaches them to perform... facility employees that receive emergency response training pursuant to Occupational Safety and Health... documents and records at the facility: (1) The job title for each position at the facility related to...

  2. 14 CFR 171.265 - Glide path performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... impressed on the microwave carrier of the radiated glide slope signal in the form of a unique summation of... TRANSPORTATION (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave... assumption that the aircraft is heading directly toward the facility. (a) The glide slope antenna system must...

  3. 14 CFR 171.265 - Glide path performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... impressed on the microwave carrier of the radiated glide slope signal in the form of a unique summation of... TRANSPORTATION (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave... assumption that the aircraft is heading directly toward the facility. (a) The glide slope antenna system must...

  4. 14 CFR 171.265 - Glide path performance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... impressed on the microwave carrier of the radiated glide slope signal in the form of a unique summation of... TRANSPORTATION (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave... assumption that the aircraft is heading directly toward the facility. (a) The glide slope antenna system must...

  5. 14 CFR 171.265 - Glide path performance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... impressed on the microwave carrier of the radiated glide slope signal in the form of a unique summation of... TRANSPORTATION (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave... assumption that the aircraft is heading directly toward the facility. (a) The glide slope antenna system must...

  6. 40 CFR 60.300 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Applicability and designation of affected facility. 60.300 Section 60.300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Grain Elevators § 60.300 Applicability and designation of affected facility. (a) The...

  7. 40 CFR 60.300 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Applicability and designation of affected facility. 60.300 Section 60.300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Grain Elevators § 60.300 Applicability and designation of affected facility. (a) The...

  8. 42 CFR 483.20 - Resident assessment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... additional assessment performed on the care areas triggered by the completion of the Minimum Data Set (MDS.... (f) Automated data processing requirement—(1) Encoding data. Within 7 days after a facility completes...) Transmitting data. Within 7 days after a facility completes a resident's assessment, a facility must be capable...

  9. 42 CFR 483.20 - Resident assessment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... additional assessment performed on the care areas triggered by the completion of the Minimum Data Set (MDS.... (f) Automated data processing requirement—(1) Encoding data. Within 7 days after a facility completes...) Transmitting data. Within 7 days after a facility completes a resident's assessment, a facility must be capable...

  10. 42 CFR 483.20 - Resident assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... additional assessment performed on the care areas triggered by the completion of the Minimum Data Set (MDS.... (f) Automated data processing requirement—(1) Encoding data. Within 7 days after a facility completes...) Transmitting data. Within 7 days after a facility completes a resident's assessment, a facility must be capable...

  11. 42 CFR 483.20 - Resident assessment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... additional assessment performed on the care areas triggered by the completion of the Minimum Data Set (MDS.... (f) Automated data processing requirement—(1) Encoding data. Within 7 days after a facility completes...) Transmitting data. Within 7 days after a facility completes a resident's assessment, a facility must be capable...

  12. 42 CFR 483.20 - Resident assessment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... additional assessment performed on the care areas triggered by the completion of the Minimum Data Set (MDS.... (f) Automated data processing requirement—(1) Encoding data. Within 7 days after a facility completes...) Transmitting data. Within 7 days after a facility completes a resident's assessment, a facility must be capable...

  13. Professional Development through Organizational Assessment: Using APPA's Facilities Management Evaluation Program

    ERIC Educational Resources Information Center

    Medlin, E. Lander; Judd, R. Holly

    2013-01-01

    APPA's Facilities Management Evaluation Program (FMEP) provides an integrated system to optimize organizational performance. The criteria for evaluation not only provide a tool for organizational continuous improvement, they serve as a compelling leadership development tool essential for today's facilities management professional. The senior…

  14. 40 CFR 60.390 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... facilities in an automobile or light-duty truck assembly plant: each prime coat operation, each guide coat... affected facility. 60.390 Section 60.390 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Automobile and Light Duty Truck Surface Coating Operations § 60.390 Applicability and...

  15. 40 CFR 60.390 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... facilities in an automobile or light-duty truck assembly plant: each prime coat operation, each guide coat... affected facility. 60.390 Section 60.390 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Automobile and Light Duty Truck Surface Coating Operations § 60.390 Applicability and...

  16. 27 CFR 24.41 - Office facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Office facilities. 24.41... § 24.41 Office facilities. The appropriate TTB officer may require the proprietor to furnish... performing Government duties whether or not such office space is located at the specific premises where...

  17. 40 CFR 440.14 - New source performance standards (NSPS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (2) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equal to the difference between annual precipitation falling on the treatment facility and the...

  18. 40 CFR 60.5380 - What standards apply to centrifugal compressor affected facilities?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false What standards apply to centrifugal compressor affected facilities? 60.5380 Section 60.5380 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Crude Oil and Natura...

  19. 40 CFR 60.5380 - What standards apply to centrifugal compressor affected facilities?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false What standards apply to centrifugal compressor affected facilities? 60.5380 Section 60.5380 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Crude Oil and Natura...

  20. 12 CFR 550.160 - What personnel and facilities may I use to perform fiduciary services?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false What personnel and facilities may I use to perform fiduciary services? 550.160 Section 550.160 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS Exercising Fiduciary Powers Fiduciary...

  1. 40 CFR 60.5375 - What standards apply to gas well affected facilities?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false What standards apply to gas well affected facilities? 60.5375 Section 60.5375 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Crude Oil and Natural Gas...

  2. 40 CFR 60.5375 - What standards apply to gas well affected facilities?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false What standards apply to gas well affected facilities? 60.5375 Section 60.5375 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Crude Oil and Natural Gas...

  3. 12 CFR 550.160 - What personnel and facilities may I use to perform fiduciary services?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 5 2011-01-01 2011-01-01 false What personnel and facilities may I use to perform fiduciary services? 550.160 Section 550.160 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS Exercising Fiduciary Powers Fiduciary...

  4. 40 CFR 408.175 - Standards of performance for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mechanized Salmon Processing Subcategory § 408.175 Standards of performance for new sources. (a) The...: (1) Any mechanized salmon processing facility located in population or processing centers including... grease 28 10 pH (1) (1) 1 Within the range 6.0 to 9.0. (2) Any mechanized salmon processing facility not...

  5. 40 CFR 408.175 - Standards of performance for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Mechanized Salmon Processing Subcategory § 408.175 Standards of performance for new sources. (a) The...: (1) Any mechanized salmon processing facility located in population or processing centers including... grease 28 10 pH (1) (1) 1 Within the range 6.0 to 9.0. (2) Any mechanized salmon processing facility not...

  6. The Biotechnology Facility for International Space Station.

    PubMed

    Goodwin, Thomas; Lundquist, Charles; Tuxhorn, Jennifer; Hurlbert, Katy

    2004-03-01

    The primary mission of the Cellular Biotechnology Program is to advance microgravity as a tool in basic and applied cell biology. The microgravity environment can be used to study fundamental principles of cell biology and to achieve specific applications such as tissue engineering. The Biotechnology Facility (BTF) will provide a state-of-the-art facility to perform cellular biotechnology research onboard the International Space Station (ISS). The BTF will support continuous operation, which will allow performance of long-duration experiments and will significantly increase the on-orbit science throughput.

  7. A software for managing after-hours activities in research user facilities

    DOE PAGES

    Camino, F. E.

    2017-05-01

    Here, we present an afterhours activity management program for shared facilities, which handles the processes required for afterhours access (request, approval, extension, etc.). It implements the concept of permitted afterhours activities, which consists of a list of well-defined activities that each user can perform afterhours. The program provides an easy and unambiguous way for users to know which activities they are allowed to perform afterhours. In addition, the program can enhance its safety efficacy by interacting with lab and instrument access control systems commonly present in user facilities.

  8. A software for managing after-hours activities in research user facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Camino, F. E.

    Here, we present an afterhours activity management program for shared facilities, which handles the processes required for afterhours access (request, approval, extension, etc.). It implements the concept of permitted afterhours activities, which consists of a list of well-defined activities that each user can perform afterhours. The program provides an easy and unambiguous way for users to know which activities they are allowed to perform afterhours. In addition, the program can enhance its safety efficacy by interacting with lab and instrument access control systems commonly present in user facilities.

  9. The test facility for the short prototypes of the LHC superconducting magnets

    NASA Astrophysics Data System (ADS)

    Delsolaro, W. Venturini; Arn, A.; Bottura, L.; Giloux, C.; Mompo, R.; Siemko, A.; Walckiers, L.

    2002-05-01

    The LHC development program relies on cryogenic tests of prototype and model magnets. This vigorous program is pursued in a dedicated test facility based on several vertical cryostats working at superfluid helium temperatures. The performance of the facility is detailed. Goals and test equipment for currently performed studies are reviewed: quench analysis and magnet protection studies, measurement of the field quality, test of ancillary electrical equipment like diodes and busbars. The paper covers the equipment available for tests of prototypes and some special series of LHC magnets to come.

  10. The Biotechnology Facility for International Space Station

    NASA Technical Reports Server (NTRS)

    Goodwin, Thomas; Lundquist, Charles; Tuxhorn, Jennifer; Hurlbert, Katy

    2004-01-01

    The primary mission of the Cellular Biotechnology Program is to advance microgravity as a tool in basic and applied cell biology. The microgravity environment can be used to study fundamental principles of cell biology and to achieve specific applications such as tissue engineering. The Biotechnology Facility (BTF) will provide a state-of-the-art facility to perform cellular biotechnology research onboard the International Space Station (ISS). The BTF will support continuous operation, which will allow performance of long-duration experiments and will significantly increase the on-orbit science throughput.

  11. Radiological performance assessment for the E-Area Vaults Disposal Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, J.R.

    This report is the first revision to ``Radiological Performance Assessment for the E-Area Vaults Disposal Facility, Revision 0'', which was issued in April 1994 and received conditional DOE approval in September 1994. The title of this report has been changed to conform to the current name of the facility. The revision incorporates improved groundwater modeling methodology, which includes a large data base of site specific geotechnical data, and special Analyses on disposal of cement-based wasteforms and naval wastes, issued after publication of Revision 0.

  12. Benchmarking Heavy Ion Transport Codes FLUKA, HETC-HEDS MARS15, MCNPX, and PHITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronningen, Reginald Martin; Remec, Igor; Heilbronn, Lawrence H.

    Powerful accelerators such as spallation neutron sources, muon-collider/neutrino facilities, and rare isotope beam facilities must be designed with the consideration that they handle the beam power reliably and safely, and they must be optimized to yield maximum performance relative to their design requirements. The simulation codes used for design purposes must produce reliable results. If not, component and facility designs can become costly, have limited lifetime and usefulness, and could even be unsafe. The objective of this proposal is to assess the performance of the currently available codes PHITS, FLUKA, MARS15, MCNPX, and HETC-HEDS that could be used for designmore » simulations involving heavy ion transport. We plan to access their performance by performing simulations and comparing results against experimental data of benchmark quality. Quantitative knowledge of the biases and the uncertainties of the simulations is essential as this potentially impacts the safe, reliable and cost effective design of any future radioactive ion beam facility. Further benchmarking of heavy-ion transport codes was one of the actions recommended in the Report of the 2003 RIA R&D Workshop".« less

  13. Health facility service availability and readiness for intrapartum and immediate postpartum care in Malawi: A cross-sectional survey

    PubMed Central

    Oseni, Lolade; Mtimuni, Angella; Sethi, Reena; Rashidi, Tambudzai; Kachale, Fannie; Rawlins, Barbara; Gupta, Shivam

    2017-01-01

    This analysis seeks to identify strengths and gaps in the existing facility capacity for intrapartum and immediate postpartum fetal and neonatal care, using data collected as a part of Malawi’s Helping Babies Breath program evaluation. From August to September 2012, the Maternal and Child Health Integrated Program (MCHIP) conducted a cross-sectional survey in 84 Malawian health facilities to capture current health facility service availability and readiness and health worker capacity and practice pertaining to labor, delivery, and immediate postpartum care. The survey collected data on availability of equipment, supplies, and medications, and health worker knowledge and performance scores on intrapartum care simulation and actual management of real clients at a subset of facilities. We ran linear regression models to identify predictors of high simulation performance of routine delivery care and management of asphyxiated newborns across all facilities surveyed. Key supplies for infection prevention and thermal care of the newborn were found to be missing in many of the surveyed facilities. At the health center level, 75% had no clinician trained in basic emergency obstetric care or newborn care and 39% had no midwife trained in the same. We observed that there were no proportional increases in available transport and staff at a facility as catchment population increased. In simulations of management of newborns with breathing problems, health workers were able to complete a median of 10 out of 16 tasks for a full-term birth case scenario and 20 out of 30 tasks for a preterm birth case scenario. Health workers who had more years of experience appeared to perform worse. Our study provides a benchmark and highlights gaps for future evaluations and studies as Malawi continues to make strides in improving facility-based care. Further progress in reducing the burden of neonatal and fetal death in Malawi will be partly predicated on guaranteeing properly equipped and staffed facilities in addition to ensuring the presence of skilled health workers. PMID:28301484

  14. Health facility service availability and readiness for intrapartum and immediate postpartum care in Malawi: A cross-sectional survey.

    PubMed

    Kozuki, Naoko; Oseni, Lolade; Mtimuni, Angella; Sethi, Reena; Rashidi, Tambudzai; Kachale, Fannie; Rawlins, Barbara; Gupta, Shivam

    2017-01-01

    This analysis seeks to identify strengths and gaps in the existing facility capacity for intrapartum and immediate postpartum fetal and neonatal care, using data collected as a part of Malawi's Helping Babies Breath program evaluation. From August to September 2012, the Maternal and Child Health Integrated Program (MCHIP) conducted a cross-sectional survey in 84 Malawian health facilities to capture current health facility service availability and readiness and health worker capacity and practice pertaining to labor, delivery, and immediate postpartum care. The survey collected data on availability of equipment, supplies, and medications, and health worker knowledge and performance scores on intrapartum care simulation and actual management of real clients at a subset of facilities. We ran linear regression models to identify predictors of high simulation performance of routine delivery care and management of asphyxiated newborns across all facilities surveyed. Key supplies for infection prevention and thermal care of the newborn were found to be missing in many of the surveyed facilities. At the health center level, 75% had no clinician trained in basic emergency obstetric care or newborn care and 39% had no midwife trained in the same. We observed that there were no proportional increases in available transport and staff at a facility as catchment population increased. In simulations of management of newborns with breathing problems, health workers were able to complete a median of 10 out of 16 tasks for a full-term birth case scenario and 20 out of 30 tasks for a preterm birth case scenario. Health workers who had more years of experience appeared to perform worse. Our study provides a benchmark and highlights gaps for future evaluations and studies as Malawi continues to make strides in improving facility-based care. Further progress in reducing the burden of neonatal and fetal death in Malawi will be partly predicated on guaranteeing properly equipped and staffed facilities in addition to ensuring the presence of skilled health workers.

  15. Performance of the first Japanese large-scale facility for radon inhalation experiments with small animals.

    PubMed

    Ishimori, Yuu; Mitsunobu, Fumihiro; Yamaoka, Kiyonori; Tanaka, Hiroshi; Kataoka, Takahiro; Sakoda, Akihiro

    2011-07-01

    A radon test facility for small animals was developed in order to increase the statistical validity of differences of the biological response in various radon environments. This paper illustrates the performances of that facility, the first large-scale facility of its kind in Japan. The facility has a capability to conduct approximately 150 mouse-scale tests at the same time. The apparatus for exposing small animals to radon has six animal chamber groups with five independent cages each. Different radon concentrations in each animal chamber group are available. Because the first target of this study is to examine the in vivo behaviour of radon and its effects, the major functions to control radon and to eliminate thoron were examined experimentally. Additionally, radon progeny concentrations and their particle size distributions in the cages were also examined experimentally to be considered in future projects.

  16. 14 CFR 145.103 - Housing and facilities requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... TRANSPORTATION (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Housing, Facilities, Equipment... temperature, humidity, and other climatic conditions sufficient to ensure personnel perform maintenance...

  17. Experiment facilities for life science experiments in space.

    PubMed

    Uchida, Satoko

    2004-11-01

    To perform experiments in microgravity environment, there should be many difficulties compared with the experiments on ground. JAXA (Japan Aerospace Exploration Agency) has developed various experiment facilities to perform life science experiments in space, such as Cell Culture Kit, Thermo Electric Incubator, Free Flow Electrophoresis Unit, Aquatic Animal Experiment Unit, and so on. The first experiment facilities were flown on Spacelab-J mission in 1992, and they were improved and modified for the 2nd International Microgravity Laboratory (IML-2) mission in 1994. Based on these experiences, some of them were further improved and flown on another missions. These facilities are continuously being improved for the International Space Station use, where high level functions and automatic operations will be required.

  18. Assessing the capacity for newborn resuscitation and factors associated with providers’ knowledge and skills: a cross-sectional study in Afghanistan

    PubMed Central

    2013-01-01

    Background Resuscitation with bag and mask is a high-impact intervention that can reduce neonatal deaths in resource-poor countries. This study assessed the capacity to perform newborn resuscitation at facilities offering comprehensive emergency obstetric and newborn care (EmONC) in Afghanistan, as well as individual and facility characteristics associated with providers’ knowledge and clinical skills. Methods Assessors interviewed 82 doctors and 142 midwives at 78 facilities on their knowledge of newborn resuscitation and observed them perform the procedure on an anatomical model. Supplies, equipment, and infrastructure were assessed at each facility. Descriptive statistics and simple and multivariate regression analyses were performed using STATA 11.2 and SAS 9.1.3. Results Over 90% of facilities had essential equipment for newborn resuscitation, including a mucus extractor, bag, and mask. More than 80% of providers had been trained on newborn resuscitation, but midwives were more likely than doctors to receive such training as part of pre-service education (59% and 35%, respectively, p < 0.001). No significant differences were found between doctors and midwives on knowledge, clinical skills, or confidence in performing newborn resuscitation. Doctors and midwives scored 71% and 66%, respectively, on knowledge questions and 66% and 71% on the skills assessment; 75% of doctors and 83% of midwives felt very confident in their ability to perform newborn resuscitation. Training was associated with greater knowledge (p < 0.001) and clinical skills (p < 0.05) in a multivariable model that adjusted for facility type, provider type, and years of experience offering EmONC services. Conclusions Lack of equipment and training do not pose major barriers to newborn resuscitation in Afghanistan, but providers’ knowledge and skills need strengthening in some areas. Midwives proved to be as capable as doctors of performing newborn resuscitation, which validates the major investment made in midwifery education. Competency-based pre-service and in-service training, complemented by supportive supervision, is an effective way to build providers’ capacity to perform newborn resuscitation. This kind of training could also help skilled birth attendants based in the community, at private clinics, or at primary care facilities save the lives of newborns. PMID:24020392

  19. Life Sciences Centrifuge Facility assessment

    NASA Technical Reports Server (NTRS)

    Benson, Robert H.

    1994-01-01

    This report provides an assessment of the status of the Centrifuge Facility being developed by ARC for flight on the International Space Station Alpha. The assessment includes technical status, schedules, budgets, project management, performance of facility relative to science requirements, and identifies risks and issues that need to be considered in future development activities.

  20. 40 CFR 60.420 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Performance for Ammonium Sulfate Manufacture § 60.420 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each ammonium sulfate dryer within an ammonium sulfate manufacturing plant in the caprolactam by-product, synthetic, and coke oven by...

  1. 40 CFR 60.420 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Performance for Ammonium Sulfate Manufacture § 60.420 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each ammonium sulfate dryer within an ammonium sulfate manufacturing plant in the caprolactam by-product, synthetic, and coke oven by...

  2. 40 CFR 60.560 - Applicability and designation of affected facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) manufacturing processes. (i) Affected facilities with a design capacity to produce less than 1,000 Mg/yr (1,102... Performance for Volatile Organic Compound (VOC) Emissions from the Polymer Manufacturing Industry § 60.560... apply to affected facilities involved in the manufacture of polypropylene, polyethylene, polystyrene, or...

  3. 40 CFR 60.420 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Performance for Ammonium Sulfate Manufacture § 60.420 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each ammonium sulfate dryer within an ammonium sulfate manufacturing plant in the caprolactam by-product, synthetic, and coke oven by...

  4. 40 CFR 60.420 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Performance for Ammonium Sulfate Manufacture § 60.420 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each ammonium sulfate dryer within an ammonium sulfate manufacturing plant in the caprolactam by-product, synthetic, and coke oven by...

  5. 40 CFR 60.500 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Bulk Gasoline Terminals § 60.500 Applicability and designation of affected facility. (a) The... bulk gasoline terminal which deliver liquid product into gasoline tank trucks. (b) Each facility under... technologies (BDT). The numerical emission limits in this standard are expressed in terms of total organic...

  6. 40 CFR 60.500 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Performance for Bulk Gasoline Terminals § 60.500 Applicability and designation of affected facility. (a) The... bulk gasoline terminal which deliver liquid product into gasoline tank trucks. (b) Each facility under... technologies (BDT). The numerical emission limits in this standard are expressed in terms of total organic...

  7. Facility Condition Assessment from A to Z

    ERIC Educational Resources Information Center

    Kaleba, Frank

    2013-01-01

    This article will provide an overview of the options for performing facility condition assessments. Quite often, the facility manager will choose a condition assessment method without deliberate examination of what type of assessment is best suited to the needs of the organization. In addition, the needs of diverse audiences usually differ--for…

  8. 14 CFR 1216.302 - Definition of key terms.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... performing in-house R&D and for planning, managing, and supporting contractor and grantee R&D), and for other... related facility equipment; design of facilities projects; and advance planning related to future facilities needs. (4) Space Flight, Control and Data Communications (SFCDC). Has similar scope to R&D but...

  9. 14 CFR 1216.302 - Definition of key terms.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... performing in-house R&D and for planning, managing, and supporting contractor and grantee R&D), and for other... related facility equipment; design of facilities projects; and advance planning related to future facilities needs. (4) Space Flight, Control and Data Communications (SFCDC). Has similar scope to R&D but...

  10. 14 CFR 1216.302 - Definition of key terms.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... performing in-house R&D and for planning, managing, and supporting contractor and grantee R&D), and for other... related facility equipment; design of facilities projects; and advance planning related to future facilities needs. (4) Space Flight, Control and Data Communications (SFCDC). Has similar scope to R&D but...

  11. 40 CFR 60.620 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Petroleum Dry Cleaners § 60.620 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities located at a petroleum dry... pounds): Petroleum solvent dry cleaning dryers, washers, filters, stills, and settling tanks. (1) When...

  12. 30 CFR 57.6800 - Storage facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...

  13. 30 CFR 57.6800 - Storage facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...

  14. 30 CFR 57.6800 - Storage facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...

  15. 30 CFR 57.6800 - Storage facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...

  16. 30 CFR 57.6800 - Storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...

  17. Redirecting Under-Utilised Computer Laboratories into Cluster Computing Facilities

    ERIC Educational Resources Information Center

    Atkinson, John S.; Spenneman, Dirk H. R.; Cornforth, David

    2005-01-01

    Purpose: To provide administrators at an Australian university with data on the feasibility of redirecting under-utilised computer laboratories facilities into a distributed high performance computing facility. Design/methodology/approach: The individual log-in records for each computer located in the computer laboratories at the university were…

  18. 40 CFR 440.44 - New source performance standards (NSPS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... December 3, 1982. (2) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equal to the difference between annual precipitation falling on the treatment facility...

  19. Materials Test Laboratory activities at the NASA-Johnson Space Center White Sands Test Facility (WSTF)

    NASA Technical Reports Server (NTRS)

    Stradling, J.; Pippen, D. L.

    1985-01-01

    The NASA Johnson Space Center White Sands Test Facility (WSTF) performs aerospace materials testing and evaluation. Established in 1963, the facility grew from a NASA site dedicated to the development of space engines for the Apollo project to a major test facility. In addition to propulsion tests, it tests materials and components, aerospace fluids, and metals and alloys in simulated space environments.

  20. Risk management study for the retired Hanford Site facilities: Qualitative risk evaluation for the retired Hanford Site facilities. Volume 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coles, G.A.; Shultz, M.V.; Taylor, W.E.

    1993-09-01

    This document provides a risk evaluation of the 100 and 200 Area retired, surplus facilities on the Hanford Site. Also included are the related data that were compiled by the risk evaluation team during investigations performed on the facilities. Results are the product of a major effort performed in fiscal year 1993 to produce qualitative information that characterizes certain risks associated with these facilities. The retired facilities investigated for this evaluation are located in the 100 and 200 Areas of the 1,450-km{sup 2} (570-mi{sup 2}) Hanford Site. The Hanford Site is a semiarid tract of land in southeastern Washington State.more » The nearest population center is Richland, Washington, (population 32,000) 30-km (20 mi) southeast of the 200 Area. During walkdown investigations of these facilities, data on real and potential hazards that threatened human health or safety or created potential environmental release issues were identified by the risk evaluation team. Using these findings, the team categorized the identified hazards by facility and evaluated the risk associated with each hazard. The factors contributing to each risk, and the consequence and likelihood of harm associated with each hazard also are included in this evaluation.« less

  1. Strategic interaction among hospitals and nursing facilities: the efficiency effects of payment systems and vertical integration.

    PubMed

    Banks, D; Parker, E; Wendel, J

    2001-03-01

    Rising post-acute care expenditures for Medicare transfer patients and increasing vertical integration between hospitals and nursing facilities raise questions about the links between payment system structure, the incentive for vertical integration and the impact on efficiency. In the United States, policy-makers are responding to these concerns by initiating prospective payments to nursing facilities, and are exploring the bundling of payments to hospitals. This paper develops a static profit-maximization model of the strategic interaction between the transferring hospital and a receiving nursing facility. This model suggests that the post-1984 system of prospective payment for hospital care, coupled with nursing facility payments that reimburse for services performed, induces inefficient under-provision of hospital services and encourages vertical integration. It further indicates that the extension of prospective payment to nursing facilities will not eliminate the incentive to vertically integrate, and will not result in efficient production unless such integration takes place. Bundling prospective payments for hospitals and nursing facilities will neither remove the incentive for vertical integration nor induce production efficiency without such vertical integration. However, bundled payment will induce efficient production, with or without vertical integration, if nursing facilities are reimbursed for services performed. Copyright 2001 John Wiley & Sons, Ltd.

  2. Reproductive health services in Malawi: an evaluation of a quality improvement intervention.

    PubMed

    Rawlins, Barbara J; Kim, Young-Mi; Rozario, Aleisha M; Bazant, Eva; Rashidi, Tambudzai; Bandazi, Sheila N; Kachale, Fannie; Sanghvi, Harshad; Noh, Jin Won

    2013-01-01

    this study was to evaluate the impact of a quality improvement initiative in Malawi on reproductive health service quality and related outcomes. (1) post-only quasi-experimental design comparing observed service quality at intervention and comparison health facilities, and (2) a time-series analysis of service statistics. sixteen of Malawi's 23 district hospitals, half of which had implemented the Performance and Quality Improvement (PQI) intervention for reproductive health at the time of the study. a total of 98 reproductive health-care providers (mostly nurse-midwives) and 139 patients seeking family planning (FP), antenatal care (ANC), labour and delivery (L&D), or postnatal care (PNC) services. health facility teams implemented a performance and quality improvement (PQI) intervention over a 3-year period. Following an external observational assessment of service quality at baseline, facility teams analysed performance gaps, designed and implemented interventions to address weaknesses, and conducted quarterly internal assessments to assess progress. Facilities qualified for national recognition by complying with at least 80% of reproductive health clinical standards during an external verification assessment. key measures include facility readiness to provide quality care, observed health-care provider adherence to clinical performance standards during service delivery, and trends in service utilisation. intervention facilities were more likely than comparison facilities to have the needed infrastructure, equipment, supplies, and systems in place to offer reproductive health services. Observed quality of care was significantly higher at intervention than comparison facilities for PNC and FP. Compared with other providers, those at intervention facilities scored significantly higher on client assessment and diagnosis in three service areas, on clinical management and procedures in two service areas, and on counselling in one service area. Service statistics suggest that the PQI intervention increased the number of Caesarean sections, but showed no impact on other indicators of service utilisation and skilled care. the PQI intervention showed a positive impact on the quality of reproductive health services. The effects of the intervention on service utilisation had likely not yet been fully realized, since none of the facilities had achieved national recognition before the evaluation. Staff turnover needs to be reduced to maximise the effectiveness of the intervention. the PQI intervention evaluated here offers an effective way to improve the quality of health services in low-resource settings and should continue to be scaled up in Malawi. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Evaluation of staff performance and material resources for integrated schistosomiasis control in northern Senegal.

    PubMed

    van der Werf, Marieke J; Mbaye, Amadou; Sow, Seydou; Gryseels, Bruno; de Vlas, Sake J

    2002-01-01

    A project to improve integrated control of schistosomiasis in the primary health care system of northern Senegal was implemented from February 1995 until September 1999, shortly after a Schistosoma mansoni outbreak. The activities included additional training of doctors and nurses in symptom-based treatment and making praziquantel (PZQ) available for an affordable price. To investigate staff performance and the availability and costs of diagnostic materials and PZQ at the end of this intervention project. We performed structured interviews with staff from 55 health care facilities in five districts. Respondents from 23 health care facilities reported both S. haematobium and S. mansoni in the coverage area, 32 reported only S. haematobium and three only S. mansoni. The average cost to patients for consultation, diagnosis, treatment and transportation to a referral health care facility was approximately 1.60 Euro. Fifty-seven per cent of the health care facilities with reported S. haematobium in the coverage area treated patients presenting with haematuria on symptoms; 56% of the health care facilities with reported S. mansoni in the coverage area treated patients presenting with blood in stool on symptoms. Thirteen per cent performed a diagnostic test for patients presenting with haematuria and 12% for patients presenting with blood in stool. The remainder, approximately one-third of the health care facilities, referred their patients to another facility for a diagnostic test. Implementation of symptom-based treatment in all health care facilities will reduce the total costs by 0.43 Euro (29%) for patients infected with S. haematobium and 0.78 Euro (46%) for patients infected with S. mansoni. Of the 53 health care facilities with schistosomiasis in their area, 37 had PZQ in stock of which 33 (88%) sold PZQ for the recommended retail price of 0.15 Euro per tablet (or 0.60 Euro per course of four tablets) or lower. Four years after the start of the intervention project, patients presenting with schistosomiasis related symptoms can generally expect proper diagnosis and treatment at all levels of the health care system in Northern Senegal, either at the initial visited health care facility or after referral. However, a further reduction of the total costs of treatment is still possible by a better implementation of symptom-based treatment and further reduction of the costs of PZQ.

  4. Evaluation of a TB infection control implementation initiative in out-patient HIV clinics in Zambia and Botswana.

    PubMed

    Emerson, C; Lipke, V; Kapata, N; Mwananyambe, N; Mwinga, A; Garekwe, M; Lanje, S; Moshe, Y; Pals, S L; Nakashima, A K; Miller, B

    2016-07-01

    Out-patient human immunodeficiency virus (HIV) care and treatment clinics in Zambia and Botswana, countries with a high burden of HIV and TB infection. To develop a tuberculosis infection control (TB IC) training and implementation package and evaluate the implementation of TB IC activities in facilities implementing the package. Prospective program evaluation of a TB IC training and implementation package using a standardized facility risk assessment tool, qualitative interviews with facility health care workers and measures of pre- and post-test performance. A composite measure of facility performance in TB IC improved from 32% at baseline to 50% at 1 year among eight facilities in Zambia, and from 27% to 80% at 6 months among 10 facilities in Botswana. Although there was marked improvement in indicators of managerial, administrative and environmental controls, key ongoing challenges remained in ensuring access to personal protective equipment and implementing TB screening in health care workers. TB IC activities at out-patient HIV clinics in Zambia and Botswana improved after training using the implementation package. Continued infrastructure support, as well as monitoring and evaluation, are needed to support the scale-up and sustainability of TB IC programs in facilities in low-resource countries.

  5. Space Station Furnace Facility. Volume 2: Appendix 1: Contract End Item specification (CEI), part 1

    NASA Technical Reports Server (NTRS)

    Seabrook, Craig

    1992-01-01

    This specification establishes the performance, design, development, and verification requirements for the Space Station Furnace Facility (SSFF) Core. The definition of the SSFF Core and its interfaces, specifies requirements for the SSFF Core performance, specifies requirements for the SSFF Core design, and construction are presented, and the verification requirements are established.

  6. 12 CFR 550.170 - May my other departments or affiliates use fiduciary personnel and facilities to perform other...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false May my other departments or affiliates use fiduciary personnel and facilities to perform other services? 550.170 Section 550.170 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS...

  7. 12 CFR 550.170 - May my other departments or affiliates use fiduciary personnel and facilities to perform other...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 5 2011-01-01 2011-01-01 false May my other departments or affiliates use fiduciary personnel and facilities to perform other services? 550.170 Section 550.170 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS...

  8. 9 CFR 592.95 - Facilities and equipment to be furnished for use of inspection program personnel in performing...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Facilities and equipment to be furnished for use of inspection program personnel in performing service. 592.95 Section 592.95 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION...

  9. Furnace and support equipment for space processing. [space manufacturing - Czochralski method

    NASA Technical Reports Server (NTRS)

    Mazelsky, R.; Duncan, C. S.; Seidensticker, R. G.; Johnson, R. A.; Hopkins, R. H.; Roland, G. W.

    1975-01-01

    A core facility capable of performing a majority of materials processing experiments is discussed. Experiment classes are described, the needs peculiar to each experiment type are outlined, and projected facility requirements to perform the experiments are treated. Control equipment (automatic control) and variations of the Czochralski method for use in space are discussed.

  10. Are facilities following best practices of pediatric abdominal CT scans?

    PubMed

    Nosek, Amy E; Hartin, Charles W; Bass, Kathryn D; Glick, Philip L; Caty, Michael G; Dayton, Merril T; Ozgediz, Doruk E

    2013-05-01

    Established guidelines for pediatric abdominal CT scans include reduced radiation dosage to minimize cancer risk and the use of intravenous (IV) contrast to obtain the highest-quality diagnostic images. We wish to determine if these practices are being used at nonpediatric facilities that transfer children to a pediatric facility. Children transferred to a tertiary pediatric facility over a 16-mo period with abdominal CT scans performed for evaluation of possible appendicitis were retrospectively reviewed for demographics, diagnosis, radiation dosage, CT contrast use, and scan quality. If CT scans were repeated, the radiation dosage between facilities was compared using Student t-test. Ninety-one consecutive children transferred from 29 different facilities had retrievable CT scan images and clinical information. Half of CT scans from transferring institutions used IV contrast. Due to poor quality or inconclusive CT scans, 19 patients required a change in management. Children received significantly less radiation at our institution compared to the referring adult facility for the same body area scanned on the same child (9.7 mSv versus 19.9 mSv, P = 0.0079). Pediatric facilities may be using less radiation per CT scan due to a heightened awareness of radiation risks and specific pediatric CT scanning protocols. The benefits of IV contrast for the diagnostic yield of pediatric CT scans should be considered to obtain the best possible image and to prevent additional imaging. Every facility performing pediatric CT scans should minimize radiation exposure, and pediatric facilities should provide feedback and education to other facilities scanning children. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. DOE High Performance Computing Operational Review (HPCOR): Enabling Data-Driven Scientific Discovery at HPC Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerber, Richard; Allcock, William; Beggio, Chris

    2014-10-17

    U.S. Department of Energy (DOE) High Performance Computing (HPC) facilities are on the verge of a paradigm shift in the way they deliver systems and services to science and engineering teams. Research projects are producing a wide variety of data at unprecedented scale and level of complexity, with community-specific services that are part of the data collection and analysis workflow. On June 18-19, 2014 representatives from six DOE HPC centers met in Oakland, CA at the DOE High Performance Operational Review (HPCOR) to discuss how they can best provide facilities and services to enable large-scale data-driven scientific discovery at themore » DOE national laboratories. The report contains findings from that review.« less

  12. How reliable are odour assessments?

    PubMed

    Bokowa, A; Beukes, J A

    2012-01-01

    This paper will demonstrate the differences found in odour test results, when odour sampling is performed at the same sources by two different consultants. By examining two case studies, this paper will highlight that the difference between the results can be significant. Both studies are based on odour sampling programs determining the odour removal efficiency of odour control units installed at two different facilities: a pet food facility and an oil/grease recycling facility. The first study is based on odour measurements at the inlet and outlet of the unit installed by Applied Plasma Physics AS at the pet food facility. Odour assessments were performed by two separate consultants at the same time. The second study is based on testing of the odour removal effectiveness of two units: a scrubber and a biofilter at an oil/grease recycling facility. During this study two odour sampling programs were performed by two consultants at different times, but under the same process conditions. This paper will show how varying results can play a role in choosing the adequate odour control technologies. The final results suggest that although, an odour control unit may appear to be insufficient, it actually is successful at removing the odours.

  13. Variations in pretransfusion practices.

    PubMed

    Padget, B J; Hannon, J L

    2003-01-01

    A variety of pretransfusion tests have been developed to improve the safety and effectiveness of transfusion. Recently, a number of traditional tests have been shown to offer limited clinical benefit and have been eliminated in many facilities. A survey of pretransfusion test practices was distributed to 116 hospital transfusion services. Routine test practices and facility size were analyzed. Ninety-one responses were received. Many smaller laboratories include tests such as anti-A,B, an autocontrol, and DAT, and immediate spin and 37 degrees Celsius microscopic readings. Nine percent never perform an Rh control with anti-D typing on patient samples. Various antibody screening and crossmatch methods are utilized. Individual laboratory test practices should be periodically assessed to ensure that they comply with standards, represent the recognized best practice, and are cost-effective. The survey responses indicate that many laboratories perform tests that are not necessary or cost-effective. These facilities should review their processes to determine which tests contribute to transfusion safety. Smaller facilities may be reluctant to change or lack the expertise necessary for this decision making and often continue to perform tests that have been eliminated in larger facilities. Consultation with larger hospital transfusion services may provide guidance for this change.

  14. Supply-side barriers to maternity-care in India: a facility-based analysis.

    PubMed

    Kumar, Santosh; Dansereau, Emily

    2014-01-01

    Health facilities in many low- and middle-income countries face several types of barriers in delivering quality health services. Availability of resources at the facility may significantly affect the volume and quality of services provided. This study investigates the effect of supply-side determinants of maternity-care provision in India. Health facility data from the District-Level Household Survey collected in 2007-2008 were analyzed to explore the effects of supply-side factors on the volume of delivery care provided at Indian health facilities. A negative binomial regression model was applied to the data due to the count and over-dispersion property of the outcome variable (number of deliveries performed at the facility). Availability of a labor room (Incidence Rate Ratio [IRR]: 1.81; 95% Confidence Interval [CI]: 1.68-1.95) and facility opening hours (IRR: 1.43; CI: 1.35-1.51) were the most significant predictors of the volume of delivery care at the health facilities. Medical and paramedical staff were found to be positively associated with institutional deliveries. The volume of deliveries was also higher if adequate beds, essential obstetric drugs, medical equipment, electricity, and communication infrastructures were available at the facility. Findings were robust to the inclusion of facility's catchment area population and district-level education, health insurance coverage, religion, wealth, and fertility. Separate analyses were performed for facilities with and without a labor room and results were qualitatively similar across these two types of facilities. Our study highlights the importance of supply-side barriers to maternity-care India. To meet Millennium Development Goals 4 and 5, policymakers should make additional investments in improving the availability of medical drugs and equipment at primary health centers (PHCs) in India.

  15. Supply-Side Barriers to Maternity-Care in India: A Facility-Based Analysis

    PubMed Central

    Kumar, Santosh; Dansereau, Emily

    2014-01-01

    Background Health facilities in many low- and middle-income countries face several types of barriers in delivering quality health services. Availability of resources at the facility may significantly affect the volume and quality of services provided. This study investigates the effect of supply-side determinants of maternity-care provision in India. Methods Health facility data from the District-Level Household Survey collected in 2007–2008 were analyzed to explore the effects of supply-side factors on the volume of delivery care provided at Indian health facilities. A negative binomial regression model was applied to the data due to the count and over-dispersion property of the outcome variable (number of deliveries performed at the facility). Results Availability of a labor room (Incidence Rate Ratio [IRR]: 1.81; 95% Confidence Interval [CI]: 1.68–1.95) and facility opening hours (IRR: 1.43; CI: 1.35–1.51) were the most significant predictors of the volume of delivery care at the health facilities. Medical and paramedical staff were found to be positively associated with institutional deliveries. The volume of deliveries was also higher if adequate beds, essential obstetric drugs, medical equipment, electricity, and communication infrastructures were available at the facility. Findings were robust to the inclusion of facility's catchment area population and district-level education, health insurance coverage, religion, wealth, and fertility. Separate analyses were performed for facilities with and without a labor room and results were qualitatively similar across these two types of facilities. Conclusions Our study highlights the importance of supply-side barriers to maternity-care India. To meet Millennium Development Goals 4 and 5, policymakers should make additional investments in improving the availability of medical drugs and equipment at primary health centers (PHCs) in India. PMID:25093729

  16. Rapid prototyping facility for flight research in artificial-intelligence-based flight systems concepts

    NASA Technical Reports Server (NTRS)

    Duke, E. L.; Regenie, V. A.; Deets, D. A.

    1986-01-01

    The Dryden Flight Research Facility of the NASA Ames Research Facility of the NASA Ames Research Center is developing a rapid prototyping facility for flight research in flight systems concepts that are based on artificial intelligence (AI). The facility will include real-time high-fidelity aircraft simulators, conventional and symbolic processors, and a high-performance research aircraft specially modified to accept commands from the ground-based AI computers. This facility is being developed as part of the NASA-DARPA automated wingman program. This document discusses the need for flight research and for a national flight research facility for the rapid prototyping of AI-based avionics systems and the NASA response to those needs.

  17. A rapid prototyping facility for flight research in advanced systems concepts

    NASA Technical Reports Server (NTRS)

    Duke, Eugene L.; Brumbaugh, Randal W.; Disbrow, James D.

    1989-01-01

    The Dryden Flight Research Facility of the NASA Ames Research Facility of the NASA Ames Research Center is developing a rapid prototyping facility for flight research in flight systems concepts that are based on artificial intelligence (AI). The facility will include real-time high-fidelity aircraft simulators, conventional and symbolic processors, and a high-performance research aircraft specially modified to accept commands from the ground-based AI computers. This facility is being developed as part of the NASA-DARPA automated wingman program. This document discusses the need for flight research and for a national flight research facility for the rapid prototyping of AI-based avionics systems and the NASA response to those needs.

  18. Revalidation of the NASA Ames 11-by 11-Foot Transonic Wind Tunnel with a Commercial Airplane Model

    NASA Technical Reports Server (NTRS)

    Kmak, Frank J.; Hudgins, M.; Hergert, D.; George, Michael W. (Technical Monitor)

    2001-01-01

    The 11-By 11-Foot Transonic leg of the Unitary Plan Wind Tunnel (UPWT) was modernized to improve tunnel performance, capability, productivity, and reliability. Wind tunnel tests to demonstrate the readiness of the tunnel for a return to production operations included an Integrated Systems Test (IST), calibration tests, and airplane validation tests. One of the two validation tests was a 0.037-scale Boeing 777 model that was previously tested in the 11-By 11-Foot tunnel in 1991. The objective of the validation tests was to compare pre-modernization and post-modernization results from the same airplane model in order to substantiate the operational readiness of the facility. Evaluation of within-test, test-to-test, and tunnel-to-tunnel data repeatability were made to study the effects of the tunnel modifications. Tunnel productivity was also evaluated to determine the readiness of the facility for production operations. The operation of the facility, including model installation, tunnel operations, and the performance of tunnel systems, was observed and facility deficiency findings generated. The data repeatability studies and tunnel-to-tunnel comparisons demonstrated outstanding data repeatability and a high overall level of data quality. Despite some operational and facility problems, the validation test was successful in demonstrating the readiness of the facility to perform production airplane wind tunnel%, tests.

  19. Facility versus unit level reporting of quality indicators in nursing homes when performance monitoring is the goal

    PubMed Central

    Norton, Peter G; Murray, Michael; Doupe, Malcolm B; Cummings, Greta G; Poss, Jeff W; Squires, Janet E; Teare, Gary F; Estabrooks, Carole A

    2014-01-01

    Objectives To demonstrate the benefit of defining operational management units in nursing homes and computing quality indicators on these units as well as on the whole facility. Design Calculation of adjusted Resident Assessment Instrument – Minimum Data Set 2.0 (RAI–MDS 2.0) quality indicators for: PRU05 (prevalence of residents with a stage 2–4 pressure ulcer), PAI0X (prevalence of residents with pain) and DRG01 (prevalence of residents receiving an antipsychotic with no diagnosis of psychosis), for quarterly assessments between 2007 and 2011 at unit and facility levels. Comparisons of these risk-adjusted quality indicators using statistical process control (control charts). Setting A representative sample of 30 urban nursing homes in the three Canadian Prairie Provinces. Measurements Explicit decision rules were developed and tested to determine whether the control charts demonstrated improving, worsening, unchanging or unclassifiable trends over the time period. Unit and facility performance were compared. Results In 48.9% of the units studied, unit control chart performance indicated different changes in quality over the reporting period than did the facility chart. Examples are provided to illustrate that these differences lead to quite different quality interventions. Conclusions Our results demonstrate the necessity of considering facility-level and unit-level measurement when calculating quality indicators derived from the RAI–MDS 2.0 data, and quite probably from any RAI measures. PMID:24523428

  20. Case-Mix Adjusting Performance Measures in a Veteran Population: Pharmacy- and Diagnosis-Based Approaches

    PubMed Central

    Liu, Chuan-Fen; Sales, Anne E; Sharp, Nancy D; Fishman, Paul; Sloan, Kevin L; Todd-Stenberg, Jeff; Nichol, W Paul; Rosen, Amy K; Loveland, Susan

    2003-01-01

    Objective To compare the rankings for health care utilization performance measures at the facility level in a Veterans Health Administration (VHA) health care delivery network using pharmacy- and diagnosis-based case-mix adjustment measures. Data Sources/Study Setting The study included veterans who used inpatient or outpatient services in Veterans Integrated Service Network (VISN) 20 during fiscal year 1998 (October 1997 to September 1998; N=126,076). Utilization and pharmacy data were extracted from VHA national databases and the VISN 20 data warehouse. Study Design We estimated concurrent regression models using pharmacy or diagnosis information in the base year (FY1998) to predict health service utilization in the same year. Utilization measures included bed days of care for inpatient care and provider visits for outpatient care. Principal Findings Rankings of predicted utilization measures across facilities vary by case-mix adjustment measure. There is greater consistency within the diagnosis-based models than between the diagnosis- and pharmacy-based models. The eight facilities were ranked differently by the diagnosis- and pharmacy-based models. Conclusions Choice of case-mix adjustment measure affects rankings of facilities on performance measures, raising concerns about the validity of profiling practices. Differences in rankings may reflect differences in comparability of data capture across facilities between pharmacy and diagnosis data sources, and unstable estimates due to small numbers of patients in a facility. PMID:14596393

  1. Control Limits for Building Energy End Use Based on Engineering Judgment, Frequency Analysis, and Quantile Regression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henze, Gregor P.; Pless, Shanti; Petersen, Anya

    2014-02-01

    Approaches are needed to continuously characterize the energy performance of commercial buildings to allow for (1) timely response to excess energy use by building operators; and (2) building occupants to develop energy awareness and to actively engage in reducing energy use. Energy information systems, often involving graphical dashboards, are gaining popularity in presenting energy performance metrics to occupants and operators in a (near) real-time fashion. Such an energy information system, called Building Agent, has been developed at NREL and incorporates a dashboard for public display. Each building is, by virtue of its purpose, location, and construction, unique. Thus, assessing buildingmore » energy performance is possible only in a relative sense, as comparison of absolute energy use out of context is not meaningful. In some cases, performance can be judged relative to average performance of comparable buildings. However, in cases of high-performance building designs, such as NREL's Research Support Facility (RSF) discussed in this report, relative performance is meaningful only when compared to historical performance of the facility or to a theoretical maximum performance of the facility as estimated through detailed building energy modeling.« less

  2. US DOE-EM On-Site Disposal Cell Working Group - Fostering Communication On Performance Assessment Challenges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seitz, Roger R.; Suttora, Linda C.; Phifer, Mark

    On-site disposal cells are in use and being considered at several U.S. Department of Energy (USDOE) sites as the final disposition for large amounts of waste associated with cleanup of contaminated areas and facilities. These facilities are typically developed with regulatory oversight from States and/or the US Environmental Protection Agency (USEPA) in addition to USDOE. The facilities are developed to meet design standards for disposal of hazardous waste as well as the USDOE performance based standards for disposal of radioactive waste. The involvement of multiple and different regulators for facilities across separate sites has resulted in some differences in expectationsmore » for performance assessments and risk assessments (PA/RA) that are developed for the disposal facilities. The USDOE-EM Office of Site Restoration formed a working group to foster improved communication and sharing of information for personnel associated with these Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) disposal cells and work towards more consistent assumptions, as appropriate, for technical and policy considerations related to performance and risk assessments in support of a Record of Decision and Disposal Authorization Statement. The working group holds teleconferences, as needed, focusing on specific topics of interest. The topics addressed to date include an assessment of the assumptions used for performance assessments and risk assessments (PA/RAs) for on-site disposal cells, requirements and assumptions related to assessment of inadvertent intrusion, DOE Manual 435.1-1 requirements, and approaches for consideration of the long-term performance of liners and covers in the context of PAs. The working group has improved communication among the staff and oversight personnel responsible for onsite disposal cells and has provided a forum to identify and resolve common concerns.« less

  3. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - A Hennessey Venom GT stands on the 3.5-mile long runway between test runs at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles. Photo credit: NASA/Kim Shiflett

  4. 40 CFR 60.340 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Lime Manufacturing Plants § 60.340 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to each rotary lime kiln used in the manufacture of lime. (b) The provisions of this subpart are not applicable to facilities used in the manufacture of lime at kraft pulp...

  5. 40 CFR 60.530 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Performance for New Residential Wood Heaters § 60.530 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each wood heater manufactured... do not apply to wood heaters constructed prior to July 1, 1988, that are or have been owned by a...

  6. 40 CFR 60.530 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Performance for New Residential Wood Heaters § 60.530 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each wood heater manufactured... do not apply to wood heaters constructed prior to July 1, 1988, that are or have been owned by a...

  7. 40 CFR 60.530 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Performance for New Residential Wood Heaters § 60.530 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each wood heater manufactured... do not apply to wood heaters constructed prior to July 1, 1988, that are or have been owned by a...

  8. Marketing Sports Facilities: Perspectives from Botswana

    ERIC Educational Resources Information Center

    Bohutsana, Basuti; Akpata, Dele

    2013-01-01

    The provision of sports facilities contributes immensely to the growth of sports and leisure activities in the countries where they are provided. In some countries, as was the case in Botswana, the government had to spend millions of dollars to provide new Integrated Sports Facilities (ISF's) as a panacea for the continued poor performance of its…

  9. The Pain in Storage: Work Safety in a High-Density Shelving Facility

    ERIC Educational Resources Information Center

    Atkins, Stephanie A.

    2005-01-01

    An increasing number of academic and research libraries have built high-density shelving facilities to address overcrowding conditions in their regular stacks. However, the work performed in these facilities is physically strenuous and highly repetitive in nature and may require the use of potentially dangerous equipment. This article will examine…

  10. National Trends in Sustainability Performance: Lessons for Facilities Leaders

    ERIC Educational Resources Information Center

    Jones, Kristy M.; Keniry, L. Julian

    2009-01-01

    For most facilities leaders, sustainability is nothing new. The authors have observed repeatedly over several decades that administrative and facilities staff have often taken the lead in initiating many of the most effective and visible efforts on campuses to dramatically curb energy use and waste and to contain costs, even during times of rapid…

  11. Do K-12 School Facilities Affect Education Outcomes? Staff Information Report.

    ERIC Educational Resources Information Center

    Young, Ed; Green, Harry A.; Roehrich-Patrick, Lynnisse; Joseph, Linda; Gibson, Teresa

    This report explains that there is growing evidence of a correlation between the adequacy of a school facility and student behavior and performance. In general, students attending school in newer, betterfacilities score 5 to 17 points higher on standardized tests than those attending in substandard buildings. School facility factors such as…

  12. A Sustainable and Holistic Approach to Design and Construction

    ERIC Educational Resources Information Center

    Bobadilla, Leo

    2010-01-01

    Building energy-efficient school facilities is not just about being "green." It is about providing high-performance facilities that are safe, healthy, and conducive to learning. It is also about building facilities that are cost-effective from their inception and in the long term. Many school districts are working under ever-tightening…

  13. 40 CFR 60.530 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for New Residential Wood Heaters § 60.530 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each wood heater manufactured... do not apply to wood heaters constructed prior to July 1, 1988, that are or have been owned by a...

  14. 40 CFR 60.530 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Performance for New Residential Wood Heaters § 60.530 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each wood heater manufactured... do not apply to wood heaters constructed prior to July 1, 1988, that are or have been owned by a...

  15. On Laminar to Turbulent Transition of Arc-Jet Flow in the NASA Ames Panel Test Facility

    NASA Technical Reports Server (NTRS)

    Gokcen, Tahir; Alunni, Antonella I.

    2012-01-01

    This paper provides experimental evidence and supporting computational analysis to characterize the laminar to turbulent flow transition in a high enthalpy arc-jet facility at NASA Ames Research Center. The arc-jet test data obtained in the 20 MW Panel Test Facility include measurements of surface pressure and heat flux on a water-cooled calibration plate, and measurements of surface temperature on a reaction-cured glass coated tile plate. Computational fluid dynamics simulations are performed to characterize the arc-jet test environment and estimate its parameters consistent with the facility and calibration measurements. The present analysis comprises simulations of the nonequilibrium flowfield in the facility nozzle, test box, and flowfield over test articles. Both laminar and turbulent simulations are performed, and the computed results are compared with the experimental measurements, including Stanton number dependence on Reynolds number. Comparisons of computed and measured surface heat fluxes (and temperatures), along with the accompanying analysis, confirm that that the boundary layer in the Panel Test Facility flow is transitional at certain archeater conditions.

  16. Gas-Grain Simulation Facility: Fundamental studies of particle formation and interactions. Volume 2: Abstracts, candidate experiments and feasibility study

    NASA Technical Reports Server (NTRS)

    Fogleman, Guy (Editor); Huntington, Judith L. (Editor); Schwartz, Deborah E. (Editor); Fonda, Mark L. (Editor)

    1989-01-01

    An overview of the Gas-Grain Simulation Facility (GGSF) project and its current status is provided. The proceedings of the Gas-Grain Simulation Facility Experiments Workshop are recorded. The goal of the workshop was to define experiments for the GGSF--a small particle microgravity research facility. The workshop addressed the opportunity for performing, in Earth orbit, a wide variety of experiments that involve single small particles (grains) or clouds of particles. Twenty experiments from the fields of exobiology, planetary science, astrophysics, atmospheric science, biology, physics, and chemistry were described at the workshop and are outlined in Volume 2. Each experiment description included specific scientific objectives, an outline of the experimental procedure, and the anticipated GGSF performance requirements. Since these experiments represent the types of studies that will ultimately be proposed for the facility, they will be used to define the general science requirements of the GGSF. Also included in the second volume is a physics feasibility study and abstracts of example Gas-Grain Simulation Facility experiments and related experiments in progress.

  17. High-Reynolds Number Active Blowing Semi-Span Force Measurement System Development

    NASA Technical Reports Server (NTRS)

    Lynn, Keith C.; Rhew, Ray D.; Acheson, Michael J.; Jones, Gregory S.; Milholen, William E.; Goodliff, Scott L.

    2012-01-01

    Recent wind-tunnel tests at the NASA Langley Research Center National Transonic Facility utilized high-pressure bellows to route air to the model for evaluating aircraft circulation control. The introduction of these bellows within the Sidewall Model Support System significantly impacted the performance of the external sidewall mounted semi-span balance. As a result of this impact on the semi-span balance measurement performance, it became apparent that a new capability needed to be built into the National Transonic Facility s infrastructure to allow for performing pressure tare calibrations on the balance in order to properly characterize its performance under the influence of static bellows pressure tare loads and bellows thermal effects. The objective of this study was to design both mechanical calibration hardware and an experimental calibration design that can be employed at the facility in order to efficiently and precisely perform the necessary loadings in order to characterize the semi-span balance under the influence of multiple calibration factors (balance forces/moments and bellows pressure/temperature). Using statistical design of experiments, an experimental design was developed allowing for strategically characterizing the behavior of the semi-span balance for use in circulation control and propulsion-type flow control testing at the National Transonic Facility.

  18. Energy Savings and Sustainability Opportunities at US Army Corps of Engineers Facilities: A Guide to Identify, Prioritize, and Estimate Projects at Complexes That Have Not Conducted a Facility-Level Energy and Water Evaluation

    DTIC Science & Technology

    2012-06-16

    Engineers to help identify and develop energy and water conservation projects in the facilities for which they are responsible. DISCLAIMER: The...and water throughout their facility. To identify energy and water conservation measures (ECMs), an energy manager would generally start by performing...an Energy and Water Conservation Assessment, essentially a facility-level evaluation of the en- ergy and water consuming equipment and systems that

  19. Synthetic Fiber Production Facilities: New Source Performance Standards (NSPS)

    EPA Pesticide Factsheets

    These standards limits emissions of volatile organic compounds (VOC) from new and reconstructed synthetic fiber production facilities that use solvent-spinning processes. Includes rule history and summary.

  20. Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit

    NASA Technical Reports Server (NTRS)

    Lewandowski, Edward J.; Schreiber, Jeffrey G.; Oriti, Salvatore M.; Meer, David W.; Brace, Michael H.; Dugala, Gina

    2010-01-01

    The Advanced Stirling Radioisotope Generator (ASRG), a high efficiency generator, is being considered for space missions. An engineering unit, the ASRG engineering unit (EU), was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently under extended operation test at the NASA Glenn Research Center (GRC) to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for the ASRG EU. This paper summarizes details of the test facility design, including the mechanical mounting, heat-rejection system, argon system, control systems, and maintenance. The effort proceeded from requirements definition through design, analysis, build, and test. Initial testing and facility performance results are discussed.

  1. Medicare Program; Prospective Payment System and Consolidated Billing for Skilled Nursing Facilities for FY 2017, SNF Value-Based Purchasing Program, SNF Quality Reporting Program, and SNF Payment Models Research. Final rule.

    PubMed

    2016-08-05

    This final rule updates the payment rates used under the prospective payment system (PPS) for skilled nursing facilities (SNFs) for fiscal year (FY) 2017. In addition, it specifies a potentially preventable readmission measure for the Skilled Nursing Facility Value-Based Purchasing Program (SNF VBP), and implements requirements for that program, including performance standards, a scoring methodology, and a review and correction process for performance information to be made public, aimed at implementing value-based purchasing for SNFs. Additionally, this final rule includes additional polices and measures in the Skilled Nursing Facility Quality Reporting Program (SNF QRP). This final rule also responds to comments on the SNF Payment Models Research (PMR) project.

  2. Mental models of audit and feedback in primary care settings.

    PubMed

    Hysong, Sylvia J; Smitham, Kristen; SoRelle, Richard; Amspoker, Amber; Hughes, Ashley M; Haidet, Paul

    2018-05-30

    Audit and feedback has been shown to be instrumental in improving quality of care, particularly in outpatient settings. The mental model individuals and organizations hold regarding audit and feedback can moderate its effectiveness, yet this has received limited study in the quality improvement literature. In this study we sought to uncover patterns in mental models of current feedback practices within high- and low-performing healthcare facilities. We purposively sampled 16 geographically dispersed VA hospitals based on high and low performance on a set of chronic and preventive care measures. We interviewed up to 4 personnel from each location (n = 48) to determine the facility's receptivity to audit and feedback practices. Interview transcripts were analyzed via content and framework analysis to identify emergent themes. We found high variability in the mental models of audit and feedback, which we organized into positive and negative themes. We were unable to associate mental models of audit and feedback with clinical performance due to high variance in facility performance over time. Positive mental models exhibit perceived utility of audit and feedback practices in improving performance; whereas, negative mental models did not. Results speak to the variability of mental models of feedback, highlighting how facilities perceive current audit and feedback practices. Findings are consistent with prior research  in that variability in feedback mental models is associated with lower performance.; Future research should seek to empirically link mental models revealed in this paper to high and low levels of clinical performance.

  3. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - The Performance Power Racing and Hennessey Performance teams pose with a Hennessey Venom GT at the 3.5-mile long runway at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The teams are, from left, Hennessey's John Heinricy, John Hennessey, Brian Smith, Performance Power Racing's Johnny Bohmer, Matt Lundy and Jeff McEachran. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles.

  4. Materials Science Experiments Under Microgravity - A Review of History, Facilities, and Future Opportunities

    NASA Technical Reports Server (NTRS)

    Stenzel, Ch.

    2012-01-01

    Materials science experiments have been a key issue already since the early days of research under microgravity conditions. A microgravity environment facilitates processing of metallic and semiconductor melts without buoyancy driven convection and sedimentation. Hence, crystal growth of semiconductors, solidification of metallic alloys, and the measurement of thermo-physical parameters are the major applications in the field of materials science making use of these dedicated conditions in space. In the last three decades a large number of successful experiments have been performed, mainly in international collaborations. In parallel, the development of high-performance research facilities and the technological upgrade of diagnostic and stimuli elements have also contributed to providing optimum conditions to perform such experiments. A review of the history of materials science experiments in space focussing on the development of research facilities is given. Furthermore, current opportunities to perform such experiments onboard ISS are described and potential future options are outlined.

  5. The Testing Behind The Test Facility: The Acoustic Design of the NASA Glenn Research Center's World-Class Reverberant Acoustic Test Facility

    NASA Technical Reports Server (NTRS)

    Hozman, Aron D.; Hughes, William O.; McNelis, Mark E.; McNelis, Anne M.

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is leading the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC's Plum Brook Station in Sandusky, Ohio, USA. Benham Companies, LLC is currently constructing modal, base-shake sine and reverberant acoustic test facilities to support the future testing needs of NASA's space exploration program. The large Reverberant Acoustic Test Facility (RATF) will be approximately 101,000 cu ft in volume and capable of achieving an empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world's known active reverberant acoustic test facilities. The key to achieving the expected acoustic test spectra for a range of many NASA space flight environments in the RATF is the knowledge gained from a series of ground acoustic tests. Data was obtained from several NASA-sponsored test programs, including testing performed at the National Research Council of Canada's acoustic test facility in Ottawa, Ontario, Canada, and at the Redstone Technical Test Center acoustic test facility in Huntsville, Alabama, USA. The majority of these tests were performed to characterize the acoustic performance of the modulators (noise generators) and representative horns that would be required to meet the desired spectra, as well as to evaluate possible supplemental gas jet noise sources. The knowledge obtained in each of these test programs enabled the design of the RATF sound generation system to confidently advance to its final acoustic design and subsequent on-going construction.

  6. Effect of Facility Ownership on Utilization of Arthroscopic Shoulder Surgery.

    PubMed

    Black, Eric M; Reynolds, John; Maltenfort, Mitchell G; Williams, Gerald R; Abboud, Joseph A; Lazarus, Mark D

    2018-03-01

    We examined practice patterns and surgical indications in the management of common shoulder procedures by surgeons practicing at physician-owned facilities. This study was a retrospective analysis of 501 patients who underwent arthroscopic shoulder procedures performed by five surgeons in our practice at one of five facilities during an 18-month period. Two of the facilities were physician-owned, and three of the five surgeons were shareholders. Demographics, insurance status, symptom duration, time from injury/symptom onset to the decision to perform surgery (at which time surgical consent is obtained), and time to schedule surgery were studied to determine the influence of facility type and physician shareholder status. Median duration of symptoms before surgery was significantly shorter in workers' compensation patients than in non-workers' compensation patients (47% less; P < 0.0001) and in men than in women (31% less; P < 0.001), but was not influenced by shareholder status or facility ownership (P > 0.05). Time between presentation and surgical consent was not influenced by facility ownership (P = 0.39) or shareholder status (P = 0.50). Time from consent to procedure was 13% faster in physician-owned facilities than in non-physician-owned facilities (P = 0.03) and 35% slower with shareholder physicians than with nonshareholder physicians (P < 0.0001). The role of physician investment in private healthcare facilities has caused considerable debate in the orthopaedic surgery field. To our knowledge, this study is the first to examine the effects of shareholder status and facility ownership on surgeons' practice patterns, surgical timing, and measures of nonsurgical treatment before shoulder surgery. Neither shareholder status nor facility ownership characteristics influenced the speed with which surgeons determined that shoulder surgery was indicated or surgeons' use of preoperative nonsurgical treatment. After the need for surgery was determined, patients underwent surgery sooner at physician-owned facilities than at non-physician-owned facilities and with nonshareholder physicians than with shareholder physicians. Level III.

  7. Lunar base launch and landing facilities conceptual design

    NASA Technical Reports Server (NTRS)

    Phillips, Paul G.; Simonds, Charles H.; Stump, William R.

    1992-01-01

    The purpose of this study was to perform a first look at the requirements for launch and landing facilities for early lunar bases and to prepared conceptual designs for some of these facilities. The emphasis of the study is on the facilities needed from the first manned landing until permanent occupancy, the Phase 2 lunar base. Factors including surface characteristics, navigation system, engine blast effects, and expected surface operations are used to develop landing pad designs, and definitions fo various other elements of the launch and landing facilities. Finally, the dependence of the use of these elements and the evolution of the facilities are established.

  8. Performance of freestanding inpatient rehabilitation hospitals before and after the rehabilitation prospective payment system.

    PubMed

    Thompson, Jon M; McCue, Michael J

    2010-01-01

    Inpatient rehabilitation hospitals provide important services to patients to restore physical and cognitive functioning. Historically, these hospitals have been reimbursed by Medicare under a cost-based system; but in 2002, Medicare implemented a rehabilitation prospective payment system (PPS). Despite the implementation of a PPS for rehabilitation, there is limited published research that addresses the operating and financial performance of these hospitals. We examined operating and financial performance in the pre- and post-PPS periods for for-profit and nonprofit freestanding inpatient rehabilitation hospitals to test for pre- and post-PPS differences within the ownership groups. We identified freestanding inpatient rehabilitation hospitals from the Centers for Medicare and Medicaid Services Health Care Cost Report Information System database for the first two fiscal years under PPS. We excluded facilities that had fiscal years less than 270 days, facilities with missing data, and government facilities. We computed average values for performance variables for the facilities in the two consecutive fiscal years post-PPS. For the pre-PPS period, we collected data on these same facilities and, once facilities with missing data and fiscal years less than 270 days were excluded, computed average values for the two consecutive fiscal years pre-PPS. Our final sample of 140 inpatient rehabilitation facilities was composed of 44 nonprofit hospitals and 96 for-profit hospitals both pre- and post-PPS. We utilized a pairwise comparison test (t-test comparison) to measure the significance of differences on each performance variable between pre- and post-PPS periods within each ownership group. Findings show that both nonprofit and for-profit freestanding inpatient rehabilitation hospitals reduced length of stay, increased discharges, and increased profitability. Within the for-profit ownership group, the percentage of Medicare discharges increased and operating expense per adjusted discharge decreased. Findings suggest that managers of these hospitals have adapted their administrative practices to conform with the financial incentives of the rehabilitation PPS. Managers must continue to control costs, increase discharges, and reduce length of stay to remain financially viable under the rehabilitation PPS.

  9. DFL, Canada's Space AIT Facilities - Current and Planned Capabilities

    NASA Astrophysics Data System (ADS)

    Singhal, R.; Mishra, S.; Choueiry, E.; Dumoulin, J.; Ahmed, S.

    2004-08-01

    The David Florida Laboratory (DFL) of the Canadian Space Agency is the Canadian national ISO 9001:2000 registered facility for the assembly, integration, and (environmental) testing of space hardware. This paper briefly describes the three main qualification facilities: Structural Qualification Facilities (SQF); Radio Frequency Qualification Facilities (RFQF); and Thermal Qualification Facilities (TQF). The paper also describes the planned/new upgrades/improvements to the DFL's existing capabilities. These include: cylindrical near-field antenna measurement system, current capabilities in multi-frequency multi-band passive intermodulation (PIM) measurement; combined thermal/vibration test facility, improvement in efficiency and performance of the photogrammetry capability, acquisition of an additional mass properties measurement system for small and micro-satellites; combined control and data acquisition system for all existing thermal vacuum facilities, plus a new automatic thermal control system and hypobaric chamber.

  10. Community College Capital Analysis Model; A Report to the Washington State Legislature. Performance Audit Report No. 75-12.

    ERIC Educational Resources Information Center

    O'Brien, John E.

    This performance audit was conducted to provide the Legislature with an evaluation of the Capital Analysis Model (CAM) utilized in the development of the Washington State Community College System capital budget request to the Legislature. The CAM is a tool for measuring projected capital facilities needs in relation to current capital facilities,…

  11. An Overview of National Transonic Facility Investigations for High Performance Military Aerodynamics (Invited)

    NASA Technical Reports Server (NTRS)

    Luckring, J. M.

    2001-01-01

    A review of National Transonic Facility (NTF) investigations for high-performance military aerodynamics has been completed. The review spans the entire operational period of the tunnel, and includes configurations ranging from full aircraft to basic research geometries. The intent for this document is to establish a comprehensive summary of these experiments with selected technical results

  12. Emergency obstetric and neonatal care availability, use, and quality: a cross-sectional study in the city of Lubumbashi, Democratic Republic of the Congo, 2011.

    PubMed

    Ntambue, Abel Mukengeshayi; Malonga, Françoise Kaj; Cowgill, Karen D; Dramaix-Wilmet, Michèle; Donnen, Philippe

    2017-01-19

    While emergency obstetric and neonatal care (EmONC) is a proxy indicator for monitoring maternal and perinatal mortalities, in Democratic Republic of the Congo (DRC), data on this care is rarely available. In the city of Lubumbashi, the second largest in DRC with an estimated population of 1.5 million, the availability, use and quality of EmONC are not known. This study aimed to assess these elements in Lubumbashi. This cross-sectional survey was conducted in April and May 2011. Fifty-three of the 180 health facilities that provide maternity care in Lubumbashi were included in this study. Only health facilities with at least six deliveries per month over the course of 2010 were included. The availability, use and quality of EmONC at each level of the health care system were assessed according to the WHO standards. The availability of EmONC in Lubumbashi falls short of WHO standards. In this study, we found one facility providing Comprehensive EmONC (CEmONC) for a catchment area of 918,819 inhabitants. Apart from the tertiary hospital (Sendwe), no other facility provided all the basic emergency obstetric and neonatal care (BEmONC) signal functions. However, all had carried out at least one of the nine signal functions during the 3 months preceding our survey: 73.6% of 53 facilities had administered parenteral antibiotics, 79.2% had systematically offered oxytocics, 39.6% had administered magnesium sulfate, 73.6% had manually evacuated placentas, 81.1% had removed retained placenta products, 54.7% had revived newborns, 35.8% had performed caesarean sections, and 47.2% had performed blood transfusions. Function 6, vaginal delivery assisted by ventouse or forceps, was performed in only two (3.8%) facilities. If this signal function was not taken into account in our assessment of EmONC availability, there would be five facilities providing CEmONC for 918,819 inhabitants, rather than one. In 2010, all the women in the surveyed facilities with obstetric complications delivered in facilities that had carried out at least one signal function in the 3 months before our survey; 7.0% of these women delivered in the facility which provided CEmONC. Mortality due to direct obstetric causes was 3.9% in the health facility that provided CEmONC. The intrapartum mortality was also high in this facility (5.1%). None of the maternity ward managers in any of the facilities surveyed had received training on the EmONC package. Essential supplies and equipment for performing certain EmONC functions were not available in all the surveyed facilities. Audits of maternal and neonatal deaths and near-misses should be established and used as a basis for monitoring the quality of care in Lubumbashi. To reduce maternal and perinatal mortality, it is essential that staff skills regarding EmONC be strengthened, the availability of supplies and equipment be increased, and that care processes be standardized in all health facilities in Lubumbashi.

  13. Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility. Part 1; Steady Predictions

    NASA Technical Reports Server (NTRS)

    Allgood, Daniel C.; Graham, Jason S.; Ahuja, Vineet; Hosangadi, Ashvin

    2008-01-01

    Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively. The Mach Number distribution shows small yet distinct differences between the two cases such as locations of shocks/shock reflections and a slightly different impingement point on the wall of the diffuser from the expansion at the exit of the nozzle. Similarly the temperature distribution indicates different flow recirculation patterns in the test cell. Both cases capture all the essential flow phenomena such as the shock-boundary layer interaction, plume expansion, expansion of the first stage ejectors, mixing between the engine plume and the first stage ejector flow and pressurization due to the first stage ejectors. The final paper will discuss thermal loads on the walls of the diffuser and cooling mechanisms investigated.

  14. Rating long-term care facilities on pressure ulcer development: importance of case-mix adjustment.

    PubMed

    Berlowitz, D R; Ash, A S; Brandeis, G H; Brand, H K; Halpern, J L; Moskowitz, M A

    1996-03-15

    To determine the importance of case-mix adjustment in interpreting differences in rates of pressure ulcer development in Department of Veterans Affairs long- term care facilities. A sample assembled from the Patient Assessment File, a Veterans Affairs administrative database, was used to derive predictors of pressure ulcer development; the resulting model was validated in a separate sample. Facility-level rates of pressure ulcer development, both unadjusted and adjusted for case mix using the predictive model, were compared. Department of Veterans Affairs long-term care facilities. The derivation sample consisted of 31 150 intermediate medicine and nursing home residents who were initially free of pressure ulcers and were institutionalized between October 1991 and April 1993. The validation sample consisted of 17 946 residents institutionalized from April 1993 to October 1993. Development of a stage 2 or greater pressure ulcer. 11 factors predicted pressure ulcer development. Validated performance properties of the resulting model were good. Model-predicted rates of pressure ulcer development at individual long-term care facilities varied from 1.9% to 6.3%, and observed rates ranged from 0% to 10.9%. Case-mix-adjusted rates and ranks of facilities differed considerably from unadjusted ratings. For example, among five facilities that were identified as high outliers on the basis of unadjusted rates, two remained as outliers after adjustment for case mix. Long-term care facilities differ in case mix. Adjustments for case mix result in different judgments about facility performance and should be used when facility incidence rates are compared.

  15. Alternative measures of spatial distribution and availability of health facilities for the delivery of emergency obstetric services in island communities.

    PubMed

    Oyerinde, Koyejo; Baravilala, Wame

    2014-12-01

    International guidelines and recommendations for availability and spatial distribution of emergency obstetric care services do not adequately address the challenges of providing emergency health services in island communities. The isolation and small population sizes that are typical of islands and remote populations limit the applicability of international guidelines in such communities. Universal access to emergency obstetric care services, when pregnant women encounter complications, is one of the three key strategies for reducing maternal and newborn mortality; the other two being family planning and skilled care during labor. The performance of selected lifesaving clinical interventions (signal functions) over a 3-month period is commonly used to assess and assign performance categories to health facilities but island communities might not have a large enough population to generate demand for all the signal functions over a 3-month period. Similarly, availability and spatial distribution recommendations are typically based on the size of catchment populations, but the populations of island communities tend to be sparsely distributed. With illustrations from six South Pacific Island states, we argue that the recommendation for availability of health facilities, that there should be at least five emergency obstetric care facilities (including at least one comprehensive facility) for every 500,000 population, and the recommendation for equitable distribution of health facilities, that all subnational areas meet the availability recommendation, can be substituted with a focus on access to blood transfusion and obstetric surgical care within 2 hours for all pregnant residents of islands. Island communities could replace the performance of signal functions over a 3-month period with a demonstrated capacity to perform signal functions if the need arises.

  16. Definition of ground test for verification of large space structure control

    NASA Technical Reports Server (NTRS)

    Glaese, John R.

    1994-01-01

    Under this contract, the Large Space Structure Ground Test Verification (LSSGTV) Facility at the George C. Marshall Space Flight Center (MSFC) was developed. Planning in coordination with NASA was finalized and implemented. The contract was modified and extended with several increments of funding to procure additional hardware and to continue support for the LSSGTV facility. Additional tasks were defined for the performance of studies in the dynamics, control and simulation of tethered satellites. When the LSSGTV facility development task was completed, support and enhancement activities were funded through a new competitive contract won by LCD. All work related to LSSGTV performed under NAS8-35835 has been completed and documented. No further discussion of these activities will appear in this report. This report summarizes the tether dynamics and control studies performed.

  17. The first PANDA tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dreier, J.; Huggenberger, M.; Aubert, C.

    1996-08-01

    The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWR) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensables in the system. The PANDA facility has a 1:1 vertical scale, and 1:25 ``system`` scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have been completed. Transient system behavior tests were conducted late in 1995; results from the first three transient tests (M3 series) aremore » reviewed. The first PANDA tests showed that the overall global behavior of the SBWR containment was globally repeatable and very favorable; the system exhibited great ``robustness.``« less

  18. Laser systems for the combustion research facility - Diana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, C.K.; Lavasek, J.W.; Jones, E.D.

    1982-03-01

    A 5-Joule/pulse, 1.8-..mu..s-pulse-width, 10-ppS flashlamp-pumped tunable-dye-laser system, called Diana, has been built for use in experiments to be performed at the Combustion Research Facility, Sandia National Laboratories, Livermore. Design specifications for the system and details of construction are described, and it is noted that performance of the laser meets or exceeds all design criteria. Areas for further performance improvements are discussed, and updates are suggested to enhance system usefulness.

  19. Alaska SAR Facility mass storage, current system

    NASA Technical Reports Server (NTRS)

    Cuddy, David; Chu, Eugene; Bicknell, Tom

    1993-01-01

    This paper examines the mass storage systems that are currently in place at the Alaska SAR Facility (SAF). The architecture of the facility will be presented including specifications of the mass storage media that are currently used and the performances that we have realized from the various media. The distribution formats and media are also discussed. Because the facility is expected to service future sensors, the new requirements and possible solutions to these requirements are also discussed.

  20. Autonomous Electrothermal Facility for Oil Recovery Intensification Fed by Wind Driven Power Unit

    NASA Astrophysics Data System (ADS)

    Belsky, Aleksey A.; Dobush, Vasiliy S.

    2017-10-01

    This paper describes the structure of autonomous facility fed by wind driven power unit for intensification of viscous and heavy crude oil recovery by means of heat impact on productive strata. Computer based service simulation of this facility was performed. Operational energy characteristics were obtained for various operational modes of facility. The optimal resistance of heating element of the downhole heater was determined for maximum operating efficiency of wind power unit.

  1. Integration Process for Payloads in the Fluids and Combustion Facility

    NASA Technical Reports Server (NTRS)

    Free, James M.; Nall, Marsha M.

    2001-01-01

    The Fluids and Combustion Facility (FCF) is an ISS research facility located in the United States Laboratory (US Lab), Destiny. The FCF is a multi-discipline facility that performs microgravity research primarily in fluids physics science and combustion science. This facility remains on-orbit and provides accommodations to multi-user and Principal investigator (PI) unique hardware. The FCF is designed to accommodate 15 PI's per year. In order to allow for this number of payloads per year, the FCF has developed an end-to-end analytical and physical integration process. The process includes provision of integration tools, products and interface management throughout the life of the payload. The payload is provided with a single point of contact from the facility and works with that interface from PI selection through post flight processing. The process utilizes electronic tools for creation of interface documents/agreements, storage of payload data and rollup for facility submittals to ISS. Additionally, the process provides integration to and testing with flight-like simulators prior to payload delivery to KSC. These simulators allow the payload to test in the flight configuration and perform final facility interface and science verifications. The process also provides for support to the payload from the FCF through the Payload Safety Review Panel (PSRP). Finally, the process includes support in the development of operational products and the operation of the payload on-orbit.

  2. Effects of physician-owned specialized facilities in health care: a systematic review.

    PubMed

    Trybou, Jeroen; De Regge, Melissa; Gemmel, Paul; Duyck, Philippe; Annemans, Lieven

    2014-12-01

    Multiple studies have investigated physician-owned specialized facilities (specialized hospitals and ambulatory surgery centres). However, the evidence is fragmented and the literature lacks cohesion. To provide a comprehensive overview of the effects of physician-owned specialized facilities by synthesizing the findings of published empirical studies. Two reviewers independently researched relevant studies using a standardized search strategy. The Institute of Medicine's quality framework (safe, effective, equitable, efficient, patient-centred, and accessible care) was applied in order to evaluate the performance of such facilities. In addition, the impact on the performance of full-service general hospitals was assessed. Forty-six studies were included in the systematic review. Overall, the quality of the included studies was satisfactory. Our results show that little evidence exists to confirm the advantages attributed to physician-owned specialized facilities, and their impact on full-service general hospitals remains limited. Although data is available on a wide variety of effects, the evidence base is surprisingly thin. There is no compelling evidence available demonstrating the added value of physician-owned specialized facilities in terms of quality or cost of the delivered care. More research is necessary on the relative merits of physician-owned specialized facilities. In addition, their corresponding impact on full-service general hospitals remains unclear. The development of physician-owned specialized facilities should thus be monitored carefully. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Fuel-Flexible Gas Turbine Combustor Flametube Facility

    NASA Technical Reports Server (NTRS)

    Little, James E.; Nemets, Stephen A.; Tornabene, Robert T.; Smith, Timothy D.; Frankenfield, Bruce J.; Manning, Stephen D.; Thompson, William K.

    2004-01-01

    Facility modifications have been completed to an existing combustor flametube facility to enable testing with gaseous hydrogen propellants at the NASA Glenn Research Center. The purpose of the facility is to test a variety of fuel nozzle and flameholder hardware configurations for use in aircraft combustors. Facility capabilities have been expanded to include testing with gaseous hydrogen, along with the existing hydrocarbon-based jet fuel. Modifications have also been made to the facility air supply to provide heated air up to 350 psig, 1100 F, and 3.0 lbm/s. The facility can accommodate a wide variety of flametube and fuel nozzle configurations. Emissions and performance data are obtained via a variety of gas sample probe configurations and emissions measurement equipment.

  4. The Sepsis Early Recognition and Response Initiative (SERRI)

    PubMed Central

    Jones, Stephen L.; Ashton, Carol M.; Kiehne, Lisa; Gigliotti, Elizabeth; Bell-Gordon, Charyl; Pinn, Teresa T.; Tran, Shirley K.; Nicolas, Juan C.; Rose, Alexis L.; Shirkey, Beverly A.; Disbot, Maureen; Masud, Faisal; Wray, Nelda P.

    2016-01-01

    Duration of Initiative 48 months and currently ongoing. Setting The Houston Methodist Hospital System and affiliated hospitals (3 facilities with 2 hospital-run skilled nursing facilities in and around Houston), St. Joseph’s Regional Health Center (1 acute care hospital and 2 skilled nursing facilities in Bryan, Texas), Hospital Corporation of America (2 acute care facilities in Houston, 1 acute care facility in McAllen, Texas [Rio Grande Valley]), Kindred Healthcare (2 long term acute care facilities in Houston), Select Medical Specialty Hospitals (2 long term acute care facilities in Houston). Whom This Should Concern Hospital administrators, quality and safety officers, performance improvement and patient safety professionals, clinic managers, infection control and prevention staff, and other physicians, nurses, and clinical staff. PMID:26892701

  5. Performing Well on Nursing Home Report Cards: Does It Pay Off?

    PubMed Central

    Park, Jeongyoung; Konetzka, R Tamara; Werner, Rachel M

    2011-01-01

    Objective To examine whether high performance or improvement on quality measures leads to economic rewards for nursing homes in the presence of public reporting. Data Sources Data from 6,286 freestanding Medicare-certified nursing homes between 1999 and 2005 were identified in Medicare Cost Reports, Minimum Data Set, and Online Survey and Certification Reporting System. Study Design Using a facility-level fixed-effects model, the effect of public reporting on financial performance was measured by comparing each of four financial outcomes (revenues, expenses, operating, and total profit margins) before (1999–2002) to after (2003–2005) public reporting was initiated. The effects were estimated separately by level of performance and improvement over time. Principal Findings Facilities that improved on publicly reported performance had increased revenues and higher profit margins after public reporting, mainly through increased Medicare admissions. High-scoring facilities showed similar patterns, though differences were not statistically significant. Conclusions Providers that improve their performance under public reporting may receive a return on their investment in quality improvement. This supports the business case for public reporting. PMID:21029093

  6. NUMERICAL FLOW AND TRANSPORT SIMULATIONS SUPPORTING THE SALTSTONE FACILITY PERFORMANCE ASSESSMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flach, G.

    2009-02-28

    The Saltstone Disposal Facility Performance Assessment (PA) is being revised to incorporate requirements of Section 3116 of the Ronald W. Reagan National Defense Authorization Act for Fiscal Year 2005 (NDAA), and updated data and understanding of vault performance since the 1992 PA (Cook and Fowler 1992) and related Special Analyses. A hybrid approach was chosen for modeling contaminant transport from vaults and future disposal cells to exposure points. A higher resolution, largely deterministic, analysis is performed on a best-estimate Base Case scenario using the PORFLOW numerical analysis code. a few additional sensitivity cases are simulated to examine alternative scenarios andmore » parameter settings. Stochastic analysis is performed on a simpler representation of the SDF system using the GoldSim code to estimate uncertainty and sensitivity about the Base Case. This report describes development of PORFLOW models supporting the SDF PA, and presents sample results to illustrate model behaviors and define impacts relative to key facility performance objectives. The SDF PA document, when issued, should be consulted for a comprehensive presentation of results.« less

  7. An inventory of aeronautical ground research facilities. Volume 1: Wind tunnels

    NASA Technical Reports Server (NTRS)

    Pirrello, C. J.; Hardin, R. D.; Heckart, M. V.; Brown, K. R.

    1971-01-01

    A survey of wind tunnel research facilities in the United States is presented. The inventory includes all subsonic, transonic, and hypersonic wind tunnels operated by governmental and private organizations. Each wind tunnel is described with respect to size, mechanical operation, construction, testing capabilities, and operating costs. Facility performance data are presented in charts and tables.

  8. 42 CFR 456.401 - State plan UR requirements and options; UR plan required for intermediate care facility services.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... required for intermediate care facility services. 456.401 Section 456.401 Public Health CENTERS FOR...: General Requirement § 456.401 State plan UR requirements and options; UR plan required for intermediate care facility services. (a) The State plan must provide that— (1) UR is performed for each ICF that...

  9. 42 CFR 456.401 - State plan UR requirements and options; UR plan required for intermediate care facility services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... required for intermediate care facility services. 456.401 Section 456.401 Public Health CENTERS FOR...: General Requirement § 456.401 State plan UR requirements and options; UR plan required for intermediate care facility services. (a) The State plan must provide that— (1) UR is performed for each ICF that...

  10. 42 CFR 456.401 - State plan UR requirements and options; UR plan required for intermediate care facility services.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... required for intermediate care facility services. 456.401 Section 456.401 Public Health CENTERS FOR...: General Requirement § 456.401 State plan UR requirements and options; UR plan required for intermediate care facility services. (a) The State plan must provide that— (1) UR is performed for each ICF that...

  11. Harbors.

    DTIC Science & Technology

    1981-07-01

    CONTRACT OR GRANT NUMBER(e) Naval Facilities Engineering Command 200 Stovall Street r Alexandria, VA 22332 (Code 0453) s. PERFORMING ORGANIZATION NAME...AND ADDRESS 10. PROGRAM ELEMENT. PROJECT. TASK • Naval Facilities Engineering Command AREA & WORK UNIT NUMBERS < 200 Stovall Street Engineering and...Design Alexandria, VA 22332 It. CONTROLLING OFFICE NAME AND ADDRESS 12. REPORT DATE ~ Naval Facilities Engineering Command (Code10432) July 1981 200

  12. NEUTRON CHARACTERIZATION OF ENSA-DPT TYPE SPENT FUEL CASK AT TRILLO NUCLEAR POWER PLANT.

    PubMed

    Méndez-Villafañe, Roberto; Campo-Blanco, Xandra; Embid, Miguel; Yéboles, César A; Morales, Ramón; Novo, Manuel; Sanz, Javier

    2018-04-23

    The Neutron Standards Laboratory of CIEMAT has conducted the characterization of the independent spent fuel storage installation at the Trillo Nuclear Power Plant. At this facility, the spent fuel assemblies are stored in ENSA-DPT type dual purpose casks. Neutron characterization was performed by dosimetry measurements with a neutron survey meter (LB6411) inside the facility, around an individual cask and between stored casks, and outside the facility. Spectra measurements were also performed with a Bonner sphere system in order to determine the integral quantities and validate the use of the neutron monitor at the different positions. Inside the facility, measured neutron spectra and neutron ambient dose equivalent rate are consistent with the casks spatial distribution and neutron emission rates, and measurements with both instruments are consistent with each other. Outside the facility, measured neutron ambient dose equivalent rates are well below the 0.5 μSv/h limit established by the nuclear regulatory authority.

  13. Supplemental multilayer insulation research facility

    NASA Technical Reports Server (NTRS)

    Dempsey, P. J.; Stochl, R. J.

    1995-01-01

    The Supplemental Multilayer Insulation Research Facility (SMIRF) provides a small scale test bed for conducting cryogenic experiments in a vacuum environment. The facility vacuum system is capable of simulating a Space Shuttle launch pressure profile as well as providing a steady space vacuum environment of 1.3 x 10(exp -4) Newton/sq meter (1 x 10(exp -6) torr). Warm side boundary temperatures can be maintained constant between 111 K (200 R) and 361 K (650 R) using a temperature controlled shroud. The shroud can also simulate a typical lunar day-night temperature profile. The test hardware consists of a cryogenic calorimeter supported by the lid of the vacuum chamber. A 0.45 cu meter (120 gallon) vacuum jacketed storage/supply tank is available for conditioning the cryogen prior to use in the calorimeter. The facility was initially designed to evaluate the thermal performance of insulation systems for long-term storage in space. The facility has recently been used to evaluate the performance of various new insulation systems for LH2 and LN2 ground storage dewars.

  14. General service and child immunization-specific readiness assessment of healthcare facilities in two selected divisions in Bangladesh.

    PubMed

    Shawon, Md Shajedur Rahman; Adhikary, Gourab; Ali, Md Wazed; Shamsuzzaman, Md; Ahmed, Shahabuddin; Alam, Nurul; Shackelford, Katya A; Woldeab, Alexander; Lim, Stephen S; Levine, Aubrey; Gakidou, Emmanuela; Uddin, Md Jasim

    2018-01-25

    Service readiness of health facilities is an integral part of providing comprehensive quality healthcare to the community. Comprehensive assessment of general and service-specific (i.e. child immunization) readiness will help to identify the bottlenecks in healthcare service delivery and gaps in equitable service provision. Assessing healthcare facilities readiness also helps in optimal policymaking and resource allocation. A health facility survey was conducted between March 2015 and December 2015 in two purposively selected divisions in Bangladesh; i.e. Rajshahi division (high performing) and Sylhet division (low performing). A total of 123 health facilities were randomly selected from different levels of service, both public and private, with variation in sizes and patient loads from the list of facilities. Data on various aspects of healthcare facility were collected by interviewing key personnel. General service and child immunization specific service readiness were assessed using the Service Availability and Readiness Assessment (SARA) manual developed by World Health Organization (WHO). The analyses were stratified by division and level of healthcare facilities. The general service readiness index for pharmacies, community clinics, primary care facilities and higher care facilities were 40.6%, 60.5%, 59.8% and 69.5%, respectively in Rajshahi division and 44.3%, 57.8%, 57.5% and 73.4%, respectively in Sylhet division. Facilities at all levels had the highest scores for basic equipment (ranged between 51.7% and 93.7%) and the lowest scores for diagnostic capacity (ranged between 0.0% and 53.7%). Though facilities with vaccine storage capacity had very high levels of service readiness for child immunization, facilities without vaccine storage capacity lacked availability of many tracer items. Regarding readiness for newly introduced pneumococcal conjugate vaccine (PCV) and inactivated polio vaccine (IPV), most of the surveyed facilities reported lack of sufficient funding and resources (antigen) for training programs. Our study suggested that health facilities suffered from lack of readiness in various aspects, most notably in diagnostic capacity. Conversely, with very few challenges, nearly all the health facilities designated to provide immunization services were ready to deliver routine childhood immunization services as well as newly introduced PCV and IPV.

  15. 49 CFR 665.11 - Testing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... braking performance, Structural Integrity, Fuel Economy, Noise, and Emissions; (c) If the new bus model... testing facility shall develop a test plan for the testing of vehicles at the facility. The test plan...

  16. Real estate planning for population health.

    PubMed

    McHugh, Margie

    2014-11-01

    Factors that health systems should consider when performing strategic assessments of their portfolios of ambulatory facilities include: Inventory. Location Facility condition. Service mix. Space use and capacity. Occupancy metrics. Strategic and economic opportunities.

  17. Mapping the Characteristics of Critical Care Facilities: Assessment, Distribution, and Level of Critical Care Facilities from Central India.

    PubMed

    Saigal, Saurabh; Sharma, Jai Prakash; Pakhare, Abhijit; Bhaskar, Santosh; Dhanuka, Sanjay; Kumar, Sanjay; Sabde, Yogesh; Bhattacharya, Pradip; Joshi, Rajnish

    2017-10-01

    In low- and middle-income countries such as India, where health systems are weak, the number of available Critical Care Unit (Intensive Care Unit [ICU]) beds is expected to be low. There is no study from the Indian subcontinent that has reported the characteristics and distribution of existing ICUs. We performed this study to understand the characteristics and distribution of ICUs in Madhya Pradesh (MP) state of Central India. We also aimed to develop a consensus scoring system and internally validate it to define levels of care and to improve health system planning and to strengthen referral networks in the state. We obtained a list of potential ICU facilities from various sources and then performed a cross-sectional survey by visiting each facility and determining characteristics for each facility. We collected variables with respect to infrastructure, human resources, equipment, support services, procedures performed, training courses conducted, and in-place policies or standard operating procedure documents. We identified a total of 123 ICUs in MP. Of 123 ICUs, 35 were level 1 facilities, 74 were level 2 facilities, and only 14 were level 3 facilities. Overall, there were 0.17 facilities per 100,000 population (95* confidence interval [CI] 0.14-0.20 per 100,000 populations). There were a total of 1816 ICU beds in the state, with an average of 2.5 beds per 100,000 population (95* CI 2.4-2.6 per 100,000 population). Of the total number of ICU beds, 250 are in level 1, 1141 are in level 2, and 425 are in level 3 facilities. This amounts to 0.34, 1.57, and 0.59 ICU beds per 100,000 population for levels 1, 2, and 3, respectively. This study could just be an eye opener for our healthcare authorities at both state and national levels to estimate the proportion of ICU beds per lac population. Similar mapping of intensive care services from other States will generate national data that is hitherto unknown.

  18. Hanford immobilized low-activity tank waste performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mann, F.M.

    1998-03-26

    The Hanford Immobilized Low-Activity Tank Waste Performance Assessment examines the long-term environmental and human health effects associated with the planned disposal of the vitrified low-level fraction of waste presently contained in Hanford Site tanks. The tank waste is the by-product of separating special nuclear materials from irradiated nuclear fuels over the past 50 years. This waste has been stored in underground single and double-shell tanks. The tank waste is to be retrieved, separated into low and high-activity fractions, and then immobilized by private vendors. The US Department of Energy (DOE) will receive the vitrified waste from private vendors and plansmore » to dispose of the low-activity fraction in the Hanford Site 200 East Area. The high-level fraction will be stored at Hanford until a national repository is approved. This report provides the site-specific long-term environmental information needed by the DOE to issue a Disposal Authorization Statement that would allow the modification of the four existing concrete disposal vaults to provide better access for emplacement of the immobilized low-activity waste (ILAW) containers; filling of the modified vaults with the approximately 5,000 ILAW containers and filler material with the intent to dispose of the containers; construction of the first set of next-generation disposal facilities. The performance assessment activity will continue beyond this assessment. The activity will collect additional data on the geotechnical features of the disposal sites, the disposal facility design and construction, and the long-term performance of the waste. Better estimates of long-term performance will be produced and reviewed on a regular basis. Performance assessments supporting closure of filled facilities will be issued seeking approval of those actions necessary to conclude active disposal facility operations. This report also analyzes the long-term performance of the currently planned disposal system as a basis to set requirements on the waste form and the facility design that will protect the long-term public health and safety and protect the environment.« less

  19. Performance evaluation of the essential dimensions of the primary health care services in six localities of Bogota–Colombia: a cross-sectional study

    PubMed Central

    2013-01-01

    Background The high segmentation and fragmentation in the provision of services are some of the main problems of the Colombian health system. In 2004 the district government of Bogota decided to implement a Primary Health Care (PHC) strategy through the Home Health program. PHC was conceived as a model for transforming health care delivery within the network of the first-level public health care facilities. This study aims to evaluate the performance of the essential dimensions of the PHC strategy in six localities geographically distributed throughout Bogotá city. Methods The rapid assessment tool to measure PHC performance, validated in Brazil, was applied. The perception of participants (users, professionals, health managers) in public health facilities where the Home Health program was implemented was compared with the perception of participants in private health facilities not implementing the program. A global performance index and specific indices for each primary care dimension were calculated. A multivariate logistic regression analysis was conducted to determine possible associations between the performance of the PHC dimensions and the self-perceived health status of users. Results The global performance index was rated as good for all participants interviewed. In general, with the exception of professionals, the differences in most of the essential dimensions seemed to favor public health care facilities where the Home Health program was implemented. The weakest dimensions were the family focus and community orientation—rated as critical by users; the distribution of financial resources—rated as critical by health managers; and, accessibility—rated as intermediate by users. Conclusions The overall findings suggest that the Home Health program could be improving the performance of the network of the first-level public health care facilities in some PHC essential dimensions, but significant efforts to achieve its objectives and raise its visibility in the community are required. PMID:23947574

  20. Measuring Work Environment and Performance in Nursing Homes

    PubMed Central

    Temkin-Greener, Helena; Zheng, Nan (Tracy); Katz, Paul; Zhao, Hongwei; Mukamel, Dana B.

    2008-01-01

    Background Qualitative studies of the nursing home work environment have long suggested that such attributes as leadership and communication may be related to nursing home performance, including residents' outcomes. However, empirical studies examining these relationships have been scant. Objectives This study is designed to: develop an instrument for measuring nursing home work environment and perceived work effectiveness; test the reliability and validity of the instrument; and identify individual and facility-level factors associated with better facility performance. Research Design and Methods The analysis was based on survey responses provided by managers (N=308) and direct care workers (N=7,418) employed in 162 facilities throughout New York State. Exploratory factor analysis, Chronbach's alphas, analysis of variance, and regression models were used to assess instrument reliability and validity. Multivariate regression models, with fixed facility effects, were used to examine factors associated with work effectiveness. Results The reliability and the validity of the survey instrument for measuring work environment and perceived work effectiveness has been demonstrated. Several individual (e.g. occupation, race) and facility characteristics (e.g. management style, workplace conditions, staffing) that are significant predictors of perceived work effectiveness were identified. Conclusions The organizational performance model used in this study recognizes the multidimensionality of the work environment in nursing homes. Our findings suggest that efforts at improving work effectiveness must also be multifaceted. Empirical findings from such a line of research may provide insights for improving the quality of the work environment and ultimately the quality of residents' care. PMID:19330892

  1. Automated System Calibration and Verification of the Position Measurements for the Los Alamos Isotope Production Facility and the Switchyard Kicker Facilities

    NASA Astrophysics Data System (ADS)

    Barr, D.; Gilpatrick, J. D.; Martinez, D.; Shurter, R. B.

    2004-11-01

    The Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory has constructed both an Isotope Production Facility (IPF) and a Switchyard Kicker (XDK) as additions to the H+ and H- accelerator. These additions contain eleven Beam Position Monitors (BPMs) that measure the beam's position throughout the transport. The analog electronics within each processing module determines the beam position using the log-ratio technique. For system reliability, calibrations compensate for various temperature drifts and other imperfections in the processing electronics components. Additionally, verifications are periodically implemented by a PC running a National Instruments LabVIEW virtual instrument (VI) to verify continued system and cable integrity. The VI communicates with the processor cards via a PCI/MXI-3 VXI-crate communication module. Previously, accelerator operators performed BPM system calibrations typically once per day while beam was explicitly turned off. One of this new measurement system's unique achievements is its automated calibration and verification capability. Taking advantage of the pulsed nature of the LANSCE-facility beams, the integrated electronics hardware and VI perform calibration and verification operations between beam pulses without interrupting production beam delivery. The design, construction, and performance results of the automated calibration and verification portion of this position measurement system will be the topic of this paper.

  2. K-12 Schools: As Good as It Gets.

    ERIC Educational Resources Information Center

    Kolleeny, Jane F.

    2003-01-01

    Introduces articles that profile innovative and well-designed school buildings. Asserts the importance of well-designed facilities on students' academic performance and questions the slow pace of design reform in educational facilities. (EV)

  3. Guidance: Use of Contract Inspectors for EPA's Federal Facility Compliance Inspections/Evaluations

    EPA Pesticide Factsheets

    This guidance clarifies that properly trained authorized and federally credentialed EPA contract inspectors can perform compliance inspections at federal facilities under the CWA, RCRA, TSCA, OPA and the SDWA.

  4. 40 CFR 60.150 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Sewage Treatment Plants § 60.150 Applicability and designation of affected facility. (a) The... (dry basis) produced by municipal sewage treatment plants, or each incinerator that charges more than...

  5. Microgravity Science Glovebox (MSG)

    NASA Technical Reports Server (NTRS)

    1998-01-01

    The Microgravity Science Glovebox is a facility for performing microgravity research in the areas of materials, combustion, fluids and biotechnology science. The facility occupies a full ISPR, consisting of: the ISPR rack and infrastructure for the rack, the glovebox core facility, data handling, rack stowage, outfitting equipment, and a video subsystem. MSG core facility provides the experiment developers a chamber with air filtering and recycling, up to two levels of containment, an airlock for transfer of payload equipment to/from the main volume, interface resources for the payload inside the core facility, resources inside the airlock, and storage drawers for MSG support equipment and consumables.

  6. Gas-Grain Simulation Facility: Fundamental studies of particle formation and interactions. Volume 1: Executive summary and overview

    NASA Technical Reports Server (NTRS)

    Fogleman, Guy (Editor); Huntington, Judith L. (Editor); Schwartz, Deborah E. (Editor); Fonda, Mark L. (Editor)

    1989-01-01

    An overview of the Gas-Grain Simulation Facility (GGSF) project and its current status is provided. The proceedings of the Gas-Grain Simulation Facility Experiments Workshop are recorded. The goal of the workshop was to define experiments for the GGSF--a small particle microgravity research facility. The workshop addressed the opportunity for performing, in Earth orbit, a wide variety of experiments that involve single small particles (grains) or clouds of particles. The first volume includes the executive summary, overview, scientific justification, history, and planned development of the Facility.

  7. Microgravity

    NASA Image and Video Library

    1998-05-01

    The Microgravity Science Glovebox is a facility for performing microgravity research in the areas of materials, combustion, fluids and biotechnology science. The facility occupies a full ISPR, consisting of: the ISPR rack and infrastructure for the rack, the glovebox core facility, data handling, rack stowage, outfitting equipment, and a video subsystem. MSG core facility provides the experiment developers a chamber with air filtering and recycling, up to two levels of containment, an airlock for transfer of payload equipment to/from the main volume, interface resources for the payload inside the core facility, resources inside the airlock, and storage drawers for MSG support equipment and consumables.

  8. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - An engineer readies a Hennessey Venom GT for test runs on the 3.5-mile long runway at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles. Photo credit: NASA/Kim Shiflett

  9. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - Mechanics, engineers and Driver Brian Smith, in jumpsuit, ready a Hennessey Venom GT for test runs on the 3.5-mile long runway at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles. Photo credit: NASA/Kim Shiflett

  10. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - Mechanics and engineers ready a Hennessey Venom GT for test runs on the 3.5-mile long runway at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles. Photo credit: NASA/Kim Shiflett

  11. Radiation shielding design of a new tomotherapy facility.

    PubMed

    Zacarias, Albert; Balog, John; Mills, Michael

    2006-10-01

    It is expected that intensity modulated radiation therapy (IMRT) and image guided radiation therapy (IGRT) will replace a large portion of radiation therapy treatments currently performed with conventional MLC-based 3D conformal techniques. IGRT may become the standard of treatment in the future for prostate and head and neck cancer. Many established facilities may convert existing vaults to perform this treatment method using new or upgraded equipment. In the future, more facilities undoubtedly will be considering de novo designs for their treatment vaults. A reevaluation of the design principles used in conventional vault design is of benefit to those considering this approach with a new tomotherapy facility. This is made more imperative as the design of the TomoTherapy system is unique in several aspects and does not fit well into the formalism of NCRP 49 for a conventional linear accelerator.

  12. Chapter 24: Strategic Energy Management (SEM) Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, James

    Strategic energy management (SEM) focuses on achieving energy-efficiency improvements through systematic and planned changes in facility operations, maintenance, and behaviors (OM&B) and capital equipment upgrades in large energy-using facilities, including industrial buildings, commercial buildings, and multi-facility organizations such as campuses or communities. Facilities can institute a spectrum of SEM actions, ranging from a simple process for regularly identifying energy-savings actions, to establishing a formal, third-party recognized or certified SEM framework for continuous improvement of energy performance. In general, SEM programs that would be considered part of a utility program will contain a set of energy-reducing goals, principles, and practices emphasizingmore » continuous improvements in energy performance or savings through energy management and an energy management system (EnMS).« less

  13. The Impact of Physical Facilities on Students' Level of Motivation and Academic Performance in Senior Secondary Schools in South West Nigeria

    ERIC Educational Resources Information Center

    Akomolafe, Comfort Olufunke; Adesua, Veronica Olubunmi

    2016-01-01

    The paper examines the relevance of physical facilities in enhancing the level of motivation and the academic performance of senior secondary school students in South West Nigeria. The study adopted ex-post facto design. The population consists of all senior secondary students in South West Nigeria. The sample for the study include one thousand…

  14. 9 CFR 592.95 - Facilities and equipment to be furnished for use of inspection program personnel in performing...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Facilities and equipment to be furnished for use of inspection program personnel in performing service. 592.95 Section 592.95 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY INSPECTION OF EGG PRODUCTS Performanc...

  15. 9 CFR 592.95 - Facilities and equipment to be furnished for use of inspection program personnel in performing...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Facilities and equipment to be furnished for use of inspection program personnel in performing service. 592.95 Section 592.95 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY INSPECTION OF EGG PRODUCTS Performanc...

  16. 9 CFR 592.95 - Facilities and equipment to be furnished for use of inspection program personnel in performing...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Facilities and equipment to be furnished for use of inspection program personnel in performing service. 592.95 Section 592.95 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY INSPECTION OF EGG PRODUCTS Performanc...

  17. 9 CFR 592.95 - Facilities and equipment to be furnished for use of inspection program personnel in performing...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Facilities and equipment to be furnished for use of inspection program personnel in performing service. 592.95 Section 592.95 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY INSPECTION OF EGG PRODUCTS Performanc...

  18. Case-Mix Adjustment of the Bereaved Family Survey.

    PubMed

    Kutney-Lee, Ann; Carpenter, Joan; Smith, Dawn; Thorpe, Joshua; Tudose, Alina; Ersek, Mary

    2018-01-01

    Surveys of bereaved family members are increasingly being used to evaluate end-of-life (EOL) care and to measure organizational performance in EOL care quality. The Bereaved Family Survey (BFS) is used to monitor EOL care quality and benchmark performance in the Veterans Affairs (VA) health-care system. The objective of this study was to develop a case-mix adjustment model for the BFS and to examine changes in facility-level scores following adjustment, in order to provide fair comparisons across facilities. We conducted a cross-sectional secondary analysis of medical record and survey data from veterans and their family members across 146 VA medical centers. Following adjustment using model-based propensity weighting, the mean change in the BFS-Performance Measure score across facilities was -0.6 with a range of -2.6 to 0.6. Fifty-five (38%) facilities changed within ±0.5 percentage points of their unadjusted score. On average, facilities that benefited most from adjustment cared for patients with greater comorbidity burden and were located in urban areas in the Northwest and Midwestern regions of the country. Case-mix adjustment results in minor changes to facility-level BFS scores but allows for fairer comparisons of EOL care quality. Case-mix adjustment of the BFS positions this National Quality Forum-endorsed measure for use in public reporting and internal quality dashboards for VA leadership and may inform the development and refinement of case-mix adjustment models for other surveys of bereaved family members.

  19. A comparison of financial performance, organizational characteristics and management strategy among rural and urban nursing facilities.

    PubMed

    Smith, H L; Piland, N F; Fisher, N

    1992-01-01

    Despite efforts to deinstitutionalize long-term care, it is estimated that 43 percent of the elderly will use a nursing facility at some point. Whether sufficient nursing facility services will be available to rural elderly is debatable due to cutbacks in governmental expenditures and recent financial losses among nursing facilities. This paper explores the challenges confronting rural nursing facilities in maintaining their viability and strategies that might be considered to improve their longevity. A comparative analysis of 18 urban and 34 rural nursing facilities in New Mexico is used in identifying promising strategic adaptations available to rural facilities. Among other considerations, rural facilities should strive to enhance revenue streams, implement strict cost control measures, emphasize broader promotional tactics, and diversify services commensurate with the constraints of the communities and populations served.

  20. Source term model evaluations for the low-level waste facility performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yim, M.S.; Su, S.I.

    1995-12-31

    The estimation of release of radionuclides from various waste forms to the bottom boundary of the waste disposal facility (source term) is one of the most important aspects of LLW facility performance assessment. In this work, several currently used source term models are comparatively evaluated for the release of carbon-14 based on a test case problem. The models compared include PRESTO-EPA-CPG, IMPACTS, DUST and NEFTRAN-II. Major differences in assumptions and approaches between the models are described and key parameters are identified through sensitivity analysis. The source term results from different models are compared and other concerns or suggestions are discussed.

  1. Annual Summary of the Integrated Disposal Facility Performance Assessment 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lehman, L. L.

    2012-03-12

    An annual summary of the adequacy of the Hanford Immobilized Low-Activity Waste (ILAW) Performance Assessment (PA) is required each year (DOE O 435.1 Chg 1,1 DOE M 435.1-1 Chg 1,2 DOE/ORP-2000-013). The most recently approved PA is DOE/ORP-2000-24.4 The ILAW PA evaluated the adequacy of the ILAW disposal facility, now referred to as the Integrated Disposal Facility (IDF), for the safe disposal of vitrified Hanford Site tank waste. More recently, a preliminary evaluation for the disposal of offsite low-level waste and mixed low-level waste was considered in RPP-1583.

  2. Strategic avionics technology definition studies. Subtask 3-1A3: Electrical Actuation (ELA) Systems Test Facility

    NASA Technical Reports Server (NTRS)

    Rogers, J. P.; Cureton, K. L.; Olsen, J. R.

    1994-01-01

    Future aerospace vehicles will require use of the Electrical Actuator systems for flight control elements. This report presents a proposed ELA Test Facility for dynamic evaluation of high power linear Electrical Actuators with primary emphasis on Thrust Vector Control actuators. Details of the mechanical design, power and control systems, and data acquisition capability of the test facility are presented. A test procedure for evaluating the performance of the ELA Test Facility is also included.

  3. A radiant heating test facility for space shuttle orbiter thermal protection system certification

    NASA Technical Reports Server (NTRS)

    Sherborne, W. D.; Milhoan, J. D.

    1980-01-01

    A large scale radiant heating test facility was constructed so that thermal certification tests can be performed on the new generation of thermal protection systems developed for the space shuttle orbiter. This facility simulates surface thermal gradients, onorbit cold-soak temperatures down to 200 K, entry heating temperatures to 1710 K in an oxidizing environment, and the dynamic entry pressure environment. The capabilities of the facility and the development of new test equipment are presented.

  4. Relationship between performance deterioration of a polyamide reverse osmosis membrane used in a seawater desalination plant and changes in its physicochemical properties.

    PubMed

    Suzuki, Tasuma; Tanaka, Ryohei; Tahara, Marina; Isamu, Yuya; Niinae, Masakazu; Lin, Lin; Wang, Jingbo; Luh, Jeanne; Coronell, Orlando

    2016-09-01

    While it is known that the performance of reverse osmosis membranes is dependent on their physicochemical properties, the existing literature studying membranes used in treatment facilities generally focuses on foulant layers or performance changes due to fouling, not on the performance and physicochemical changes that occur to the membranes themselves. In this study, the performance and physicochemical properties of a polyamide reverse osmosis membrane used for three years in a seawater desalination plant were compared to those of a corresponding unused membrane. The relationship between performance changes during long-term use and changes in physicochemical properties was evaluated. The results showed that membrane performance deterioration (i.e., reduced water flux, reduced contaminant rejection, and increased fouling propensity) occurred as a result of membrane use in the desalination facility, and that the main physicochemical changes responsible for performance deterioration were reduction in PVA coating coverage and bromine uptake by polyamide. The latter was likely promoted by oxidant residual in the membrane feed water. Our findings indicate that the optimization of membrane materials and processes towards maximizing the stability of the PVA coating and ensuring complete removal of oxidants in feed waters would minimize membrane performance deterioration in water purification facilities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Complaints in for-profit, non-profit and public nursing homes in two Canadian provinces

    PubMed Central

    McGregor, Margaret J; Cohen, Marcy; Stocks-Rankin, Catherine-Rose; Cox, Michelle B; Salomons, Kia; McGrail, Kimberlyn M; Spencer, Charmaine; Ronald, Lisa A; Schulzer, Michael

    2011-01-01

    Background Nursing homes provide long-term housing, support and nursing care to frail elders who are no longer able to function independently. Although studies conducted in the United States have demonstrated an association between for-profit ownership and inferior quality, relatively few Canadian studies have made performance comparisons with reference to type of ownership. Complaints are one proxy measure of performance in the nursing home setting. Our study goal was to determine whether there is an association between facility ownership and the frequency of nursing home complaints. Methods We analyzed publicly available data on complaints, regulatory measures, facility ownership and size for 604 facilities in Ontario over 1 year (2007/08) and 62 facilities in British Columbia (Fraser Health region) over 4 years (2004–2008). All analyses were carried out at the facility level. Negative binomial regression analysis was used to assess the association between type of facility ownership and frequency of complaints. Results The mean (standard deviation) number of verified/substantiated complaints per 100 beds per year in Ontario and Fraser Health was 0.45 (1.10) and 0.78 (1.63) respectively. Most complaints related to resident care. Complaints were more frequent in facilities with more citations, i.e., violations of the legislation or regulations governing a home, (Ontario) and inspection violations (Fraser Health). Compared with Ontario’s for-profit chain facilities, adjusted incident rate ratios and 95% confidence intervals of verified complaints were 0.56 (0.27–1.16), 0.58 (0.34–1.00), 0.43 (0.21– 0.88), and 0.50 (0.30– 0.84) for for-profit single-site, non-profit, charitable, and public facilities respectively. In Fraser Health, the adjusted incident rate ratio of substantiated complaints in non-profit facilities compared with for-profit facilities was 0.18 (0.07–0.45). Interpretation Compared with for-profit chain facilities, non-profit, charitable and public facilities had significantly lower rates of complaints in Ontario. Likewise, in British Columbia’s Fraser Health region, non-profit owned facilities had significantly lower rates of complaints compared with for-profit owned facilities. PMID:22567074

  6. Quantifying surgical and anesthetic availability at primary health facilities in Mongolia.

    PubMed

    Spiegel, David A; Choo, Shelly; Cherian, Meena; Orgoi, Sergelen; Kehrer, Beat; Price, Raymond R; Govind, Salik

    2011-02-01

    Significant barriers limit the safe and timely provision of surgical and anaesthetic care in low- and middle-income countries. Nearly one-half of Mongolia's population resides in rural areas where the austere geography makes travel for adequate surgical care very difficult. Our goal was to characterize the availability of surgical and anaesthetic services, in terms of infrastructure capability, physical resources (supplies and equipment), and human resources for health at primary level health facilities in Mongolia. A situational analysis of the capacity to deliver emergency and essential surgical care (EESC) was performed in a nonrandom sample of 44 primary health facilities throughout Mongolia. Significant shortfalls were noted in the capacity to deliver surgical and anesthetic services. Deficiencies in infrastructure and supplies were common, and there were no trained surgeons or anaesthesiologists at any of the health facilities sampled. Most procedures were performed by general doctors and paraprofessionals, and occasionally visiting surgeons from higher levels of the health system. While basic interventions such as suturing or abscess drainage were commonly performed, the availability of many essential interventions was absent at a significant number of facilities. This situational analysis of the availability of essential surgical and anesthetic services identified significant deficiencies in infrastructure, supplies, and equipment, as well as a lack of human resources at the primary referral level facilities in Mongolia. Given the significant travel distances to secondary level facilities for the majority of the rural population, there is an urgent need to strengthen the delivery of essential surgical and anaesthetic services at the primary referral level (soum and intersoum). This will require a multidisciplinary, multi-sectoral effort aimed to improve infrastructure, procure and maintain essential equipment and supplies, and train appropriate health professionals.

  7. A standards-based approach to quality improvement for HIV services at Zambia Defence Force facilities: results and lessons learned.

    PubMed

    Kols, Adrienne; Kim, Young-Mi; Bazant, Eva; Necochea, Edgar; Banda, Joseph; Stender, Stacie

    2015-07-01

    The Zambia Defence Force adopted the Standards-Based Management and Recognition approach to improve the quality of the HIV-related services at its health facilities. This quality improvement intervention relies on comprehensive, detailed assessment tools to communicate and verify adherence to national standards of care, and to test and implement changes to improve performance. A quasi-experimental evaluation of the intervention was conducted at eight Zambia Defence Force primary health facilities (four facilities implemented the intervention and four did not). Data from three previous analyses are combined to assess the effect of Standards-Based Management and Recognition on three domains: facility readiness to provide services; observed provider performance during antiretroviral therapy (ART) and antenatal care consultations; and provider perceptions of the work environment. Facility readiness scores for ART improved on four of the eight standards at intervention sites, and one standard at comparison sites. Facility readiness scores for prevention of mother-to-child transmission (PMTCT) of HIV increased by 15 percentage points at intervention sites and 7 percentage points at comparison sites. Provider performance improved significantly at intervention sites for both ART services (from 58 to 84%; P < 0.01) and PMTCT services (from 58 to 73%; P = 0.003); there was no significant change at comparison sites. Providers' perceptions of the work environment generally improved at intervention sites and declined at comparison sites; differences in trends between study groups were significant for eight items. A standards-based approach to quality improvement proved effective in supporting healthcare managers and providers to deliver ART and PMTCT services in accordance with evidence-based standards in a health system suffering from staff shortages.

  8. The Testing Behind the Test Facility: the Acoustic Design of the NASA Glenn Research Center's World-Class Reverberant Acoustic Test Facility

    NASA Technical Reports Server (NTRS)

    Hughes, William O.; McNelis, Mark E.; Hozman, Aron D.; McNelis, Anne M.

    2010-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is leading the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC s Plum Brook Station in Sandusky, Ohio, U.S.A. Benham Companies, LLC is currently constructing modal, base-shake sine and reverberant acoustic test facilities to support the future testing needs of NASA s space exploration program. The large Reverberant Acoustic Test Facility (RATF) will be approximately 101,000 ft3 in volume and capable of achieving an empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world s known active reverberant acoustic test facilities. The key to achieving the expected acoustic test spectra for a range of many NASA space flight environments in the RATF is the knowledge gained from a series of ground acoustic tests. Data was obtained from several NASA-sponsored test programs, including testing performed at the National Research Council of Canada s acoustic test facility in Ottawa, Ontario, Canada, and at the Redstone Technical Test Center acoustic test facility in Huntsville, Alabama, U.S.A. The majority of these tests were performed to characterize the acoustic performance of the modulators (noise generators) and representative horns that would be required to meet the desired spectra, as well as to evaluate possible supplemental gas jet noise sources. The knowledge obtained in each of these test programs enabled the design of the RATF sound generation system to confidently advance to its final acoustic design and subsequent ongoing construction.

  9. The Testing Behind The Test Facility: The Acoustic Design of the NASA Glenn Research Center's World-Class Reverberant Acoustic Test Facility

    NASA Technical Reports Server (NTRS)

    Hughes, William O.; McNelis, Mark E.; McNelis, Anne M.

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is leading the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC?s Plum Brook Station in Sandusky, Ohio, USA. Benham Companies, LLC is currently constructing modal, base-shake sine and reverberant acoustic test facilities to support the future testing needs of NASA?s space exploration program. T he large Reverberant Acoustic Test Facility (RATF) will be approximately 101,000 ft3 in volume and capable of achieving an empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world?s known active reverberant acoustic test facilities. The key to achieving the expected acoustic test spectra for a range of many NASA space flight environments in the RATF is the knowledge gained from a series of ground acoustic tests. Data was obtained from several NASA-sponsored test programs, including testing performed at the National Research Council of Canada?s acoustic test facility in Ottawa, Ontario, Canada, and at the Redstone Technical Test Center acoustic test facility in Huntsville, Alabama, USA. The majority of these tests were performed to characterize the acoustic performance of the modulators (noise generators) and representative horns that would be required to meet the desired spectra, as well as to evaluate possible supplemental gas jet noise sources. The knowledge obtained in each of these test programs enabled the design of the RATF sound generation system to confidently advance to its final acoustic de-sign and subsequent on-going construction.

  10. Relationship between built environment attributes and physical function in Japanese community-dwelling older adults.

    PubMed

    Soma, Yuki; Tsunoda, Kenji; Kitano, Naruki; Jindo, Takashi; Tsuji, Taishi; Saghazadeh, Mahshid; Okura, Tomohiro

    2017-03-01

    To explore the relationships between the built environment and older adults' physical function. The present cross-sectional study carried out in 2010-2012 used data drawn from 509 community-dwelling older adults aged 65-86 years living in Kasama City, a Japanese rural region. We evaluated physical function with the following performance tests: grip strength, sit-to-stand, timed up & go and walking speed. Using geographic information systems, we measured population density and the number of destinations related to daily life, community centers, medical facilities and recreational facilities within participants' neighborhoods. After adjusting for potential confounders, we found lower population density was related to poor performance of sit-to-stand and walking speed in both sexes, and grip strength in women (trend P < 0.05). A lower number of daily life-related destinations was related to poor performance of sit-to-stand and walking speed in men, and grip strength and sit-to-stand in women. Similarly, the number of community centers was related to walking speed in both sexes. The number of medical and recreational facilities was also related to some physical performance in both sexes. A lower land use mix score, calculated by principal component analysis, was related to lower performance of sit-to-stand and walking speed in men, and grip strength and sit-to-stand in women. The present study suggests that, although there are some sex differences, low population density, land use mix, and fewer daily life-related destinations, community centers, medical facilities and recreational facilities are negative determinants of physical function. Geriatr Gerontol Int 2017; 17: 382-390. © 2016 Japan Geriatrics Society.

  11. A robotic observatory in the city

    NASA Astrophysics Data System (ADS)

    Ruch, Gerald T.; Johnston, Martin E.

    2012-05-01

    The University of St. Thomas (UST) Observatory is an educational facility integrated into UST's undergraduate curriculum as well as the curriculum of several local schools. Three characteristics combine to make the observatory unique. First, the telescope is tied directly to the support structure of a four-story parking ramp instead of an isolated pier. Second, the facility can be operated remotely over an Internet connection and is capable of performing observations without a human operator. Third, the facility is located on campus in the heart of a metropolitan area where light pollution is severe. Our tests indicate that, despite the lack of an isolated pier, vibrations from the ramp do not degrade the image quality at the telescope. The remote capability facilitates long and frequent observing sessions and allows others to use the facility without traveling to UST. Even with the high background due to city lights, the sensitivity and photometric accuracy of the system are sufficient to fulfill our pedagogical goals and to perform a variety of scientific investigations. In this paper, we outline our educational mission, provide a detailed description of the observatory, and discuss its performance characteristics.

  12. Mobile CARS - IRS Instrument for Simultaneous Spectroscopic Measurement of Multiple Properties in Gaseous Flows

    NASA Technical Reports Server (NTRS)

    Bivolaru, Daniel; Lee, Joseph W.; Jones, Stephen B.; Tedder, Sarah A.; Danehy, Paul M.; Weikl, M. C.; Magnotti, G.; Cutler, Andrew D.

    2007-01-01

    This paper describes a measurement system based on the dual-pump coherent anti-Stokes Raman spectroscopy (CARS) and interferometric Rayleigh scattering (IRS) methods. The IRS measurement is performed simultaneously with the CARS measurement using a common green laser beam as a narrow-band light source. The mobile CARS-IRS instrument is designed for the use both in laboratories as well as in ground-based combustion test facilities. Furthermore, it is designed to be easily transported between laboratory and test facility. It performs single-point spatially and temporally resolved simultaneous measurements of temperature, species mole fraction of N2, O2, and H2, and two-components of velocity. A mobile laser system can be placed inside or outside the test facility, while a beam receiving and monitoring system is placed near the measurement location. Measurements in a laboratory small-scale Mach 1.6 H2-air combustion-heated supersonic jet were performed to test the capability of the system. Final setup and pretests of a larger scale reacting jet are ongoing at NASA Langley Research Center s Direct Connect Supersonic Combustor Test Facility (DCSCTF).

  13. The Characterization of a Piston Displacement-Type Flowmeter Calibration Facility and the Calibration and Use of Pulsed Output Type Flowmeters

    PubMed Central

    Mattingly, G. E.

    1992-01-01

    Critical measurement performance of fluid flowmeters requires proper and quantified verification data. These data should be generated using calibration and traceability techniques established for these verification purposes. In these calibration techniques, the calibration facility should be well-characterized and its components and performance properly traced to pertinent higher standards. The use of this calibrator to calibrate flowmeters should be appropriately established and the manner in which the calibrated flowmeter is used should be specified in accord with the conditions of the calibration. These three steps: 1) characterizing the calibration facility itself, 2) using the characterized facility to calibrate a flowmeter, and 3) using the calibrated flowmeter to make a measurement are described and the pertinent equations are given for an encoded-stroke, piston displacement-type calibrator and a pulsed output flowmeter. It is concluded that, given these equations and proper instrumentation of this type of calibrator, very high levels of performance can be attained and, in turn, these can be used to achieve high fluid flow rate measurement accuracy with pulsed output flowmeters. PMID:28053444

  14. An Evaluation of the Additional Acoustic Power Needed to Overcome the Effects of a Test-Article's Absorption During Reverberant Chamber Acoustic Testing of Spaceflight Hardware

    NASA Technical Reports Server (NTRS)

    Hozman, Aron D.; Hughes, William O.

    2014-01-01

    The exposure of a customer's aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facility's available acoustic power capability becomes maximized with the test-article installed during the actual test then the customer's environment requirement may become compromised. In order to understand the risk of not achieving the customer's in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Station's Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.

  15. An Evaluation of the Additional Acoustic Power Needed to Overcome the Effects of a Test-Article's Absorption during Reverberant Chamber Acoustic Testing of Spaceflight Hardware

    NASA Technical Reports Server (NTRS)

    Hozman, Aron D.; Hughes, William O.

    2014-01-01

    The exposure of a customers aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facilitys available acoustic power capability becomes maximized with the test-article installed during the actual test then the customers environment requirement may become compromised. In order to understand the risk of not achieving the customers in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Stations Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.

  16. A Novel Knock-Out Animal Model to Analyze Transcriptional Signaling by p53 Tumor Suppressor Protein in Breast Cancer

    DTIC Science & Technology

    2002-05-01

    homozygous for the pcna and p21 mutant genes will be accomplised with the help of Gene Targeting and Transgenic Facility at the Rosewel Park Cancer Institute...screening of BAC library was performed with the help of the DNA Microarray Facility Facility at the Rosewel Park Cancer Institute. Sequence of mouse

  17. EVA Training and Development Facilities

    NASA Technical Reports Server (NTRS)

    Cupples, Scott

    2016-01-01

    Overview: Vast majority of US EVA (ExtraVehicular Activity) training and EVA hardware development occurs at JSC; EVA training facilities used to develop and refine procedures and improve skills; EVA hardware development facilities test hardware to evaluate performance and certify requirement compliance; Environmental chambers enable testing of hardware from as large as suits to as small as individual components in thermal vacuum conditions.

  18. Source inventory for Department of Energy solid low-level radioactive waste disposal facilities: What it means and how to get one of your own

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, M.A.

    1991-12-31

    In conducting a performance assessment for a low-level waste (LLW) disposal facility, one of the important considerations for determining the source term, which is defined as the amount of radioactivity being released from the facility, is the quantity of radioactive material present. This quantity, which will be referred to as the source inventory, is generally estimated through a review of historical records and waste tracking systems at the LLW facility. In theory, estimating the total source inventory for Department of Energy (DOE) LLW disposal facilities should be possible by reviewing the national data base maintained for LLW operations, the Solidmore » Waste Information Management System (SWIMS), or through the annual report that summarizes the SWIMS data, the Integrated Data Base (IDB) report. However, in practice, there are some difficulties in making this estimate. This is not unexpected, since the SWIMS and the IDB were not developed with the goal of developing a performance assessment source term in mind. The practical shortcomings using the existing data to develop a source term for DOE facilities will be discussed in this paper.« less

  19. Greening Federal Facilities: An Energy, Environmental, and Economic Resource Guide for Federal Facility Managers and Designers; Second Edition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, A.

    2001-05-16

    Greening Federal Facilities, Second Edition, is a nuts-and-bolts resource guide compiled to increase energy and resource efficiency, cut waste, and improve the performance of Federal buildings and facilities. The guide highlights practical actions that facility managers, design and construction staff, procurement officials, and facility planners can take to save energy and money, improve the comfort and productivity of employees, and benefit the environment. It supports a national effort to promote energy and environmental efficiency in the nation's 500,000 Federal buildings and facilities. Topics covered include current Federal regulations; environmental and energy decision-making; site and landscape issues; building design; energy systems;more » water and wastewater; materials; waste management, and recycling; indoor environmental quality; and managing buildings.« less

  20. Maintenance Business Plans.

    ERIC Educational Resources Information Center

    Adams, Matt

    2002-01-01

    Discusses maintenance business plans, statements which provide accountability for facilities maintenance organizations' considerable budgets. Discusses the plan's components: statement of plan objectives, macro and detailed description of the facility assets, maintenance function descriptions, description of key performance indicators, milestone…

  1. 76 FR 68170 - Instructions for Implementing Sustainable Locations for Federal Facilities in Accordance With...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-03

    ... for integrating sustainable facility location decision-making principles into agency policies and..., Energy, and Economic Performance,'' signed by President Obama on October 5, 2009. 74 FR 52117, Oct. 8...

  2. WASTE OPPORTUNITY ASSESSMENT: A PHOTOFINISHING FACILITY

    EPA Science Inventory

    A waste minimization opportunity assessment was performed which identified areas for waste reduction at a photofinishing facility. The study followed procedures in the EPA Waste Minimization Opportunity Assessment Manual. The report identifies potential options to achieve further...

  3. 45 CFR 63.21 - Obligation and liquidation by grantee.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... utilities, for travel, and for the rental of facilities, shall be considered to have been obligated as of the time such services were rendered, such travel was performed, and such rented facilities were used...

  4. Coordination between airway facilities specialists and air traffic personnel.

    DOT National Transportation Integrated Search

    2002-04-01

    Airway Facilities (AF) is responsible for providing services and conducting operations that deliver the highest possible levels of National Airspace System (NAS) safety and efficiency. To accomplish this, AF specialists perform maintenance tasks for ...

  5. 40 CFR 60.140 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Performance for Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After... which the provisions of this subpart apply is each basic oxygen process furnace. (b) Any facility under...

  6. 40 CFR 60.140 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Performance for Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After... which the provisions of this subpart apply is each basic oxygen process furnace. (b) Any facility under...

  7. 40 CFR 60.140 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Performance for Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After... which the provisions of this subpart apply is each basic oxygen process furnace. (b) Any facility under...

  8. 40 CFR 60.140 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Performance for Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After... which the provisions of this subpart apply is each basic oxygen process furnace. (b) Any facility under...

  9. 40 CFR 60.140 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Primary Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After... which the provisions of this subpart apply is each basic oxygen process furnace. (b) Any facility under...

  10. Characteristics and performance of a superconducting bumpy-torus magnet facility for plasma research

    NASA Technical Reports Server (NTRS)

    Roth, J. R.; Holmes, A. D.; Keller, T. A.; Krawczonek, W. M.

    1973-01-01

    The NASA Lewis bumpy-torus facility consists of 12 superconducting coils, each 19 cm i.d. and capable of 3.0 T on its axis. The coils are equally spaced around a toroidal array with a major diameter of 1.52 m; they are mounted with the major axis of the torus vertical in a single vacuum tank 2.6 m in diameter. Tests of the facility mapped out its magnetic, cryogenic, vacuum, mechanical, and electrical performance. The design value of the maximum magnetic field on the magnetic axis, 3.0 T, was reached and exceeded. A maximum magnetic field of 3.23 T was held for a period of 60 minutes. When the coils were charged to a maximum magnetic field of 3.35 T, the coil system went normal without apparent damage or degradation of performance.

  11. A research study for the preliminary definition of an aerophysics free-flight laboratory facility

    NASA Technical Reports Server (NTRS)

    Canning, Thomas N.

    1988-01-01

    A renewed interest in hypervelocity vehicles requires an increase in the knowledge of aerodynamic phenomena. Tests conducted with ground-based facilities can be used both to better understand the physics of hypervelocity flight, and to calibrate and validate computer codes designed to predict vehicle performance in the hypervelocity environment. This research reviews the requirements for aerothermodynamic testing and discusses the ballistic range and its capabilities. Examples of the kinds of testing performed in typical high performance ballistic ranges are described. We draw heavily on experience obtained in the ballistics facilities at NASA Ames Research Center, Moffett Field, California. Prospects for improving the capabilities of the ballistic range by using advanced instrumentation are discussed. Finally, recent developments in gun technology and their application to extend the capability of the ballistic range are summarized.

  12. Establishing repeatable operation of a centrifugal compressor research facility for aerodynamic investigations

    NASA Astrophysics Data System (ADS)

    Dolan, Matthew Philip

    The objective of this research has been to analyze the steady state performance of a new centrifugal compressor research facility. The CSTAR (Centrifugal STage for Aerodynamic Research) compressor has been designed to be placed as the last stage in an axial compressor and its performance in this flow regime was measured. Because the compressor was designed as a research vehicle, unique instrumentation throughout the flow path provides a detailed look at its steady state performance. Rakes at the inlet and deswirl section quantify the overall performance but other instrumentation is used to understand the component performance. Static pressure taps along the shroud, within the diffuser, and through the turn-to-axial show the static pressure rise. Additionally, rakes at the inlet and exit of diffuser also characterize the performance of the wedge diffuser and the impeller. Additionally, capacitance probes located at the knee and exducer of the impeller non-intrusively measure the size of the tip clearance during facility operation. An investigation into these measurements resulted in a standard procedure for in-situ calibration and installation to produce repeatable and accurate clearance measurements. Finally, the feasibility of future Laser Doppler Velocimetry measurements acquired through the shroud window was tested and was found to be achievable with the use of beam translators to ensure that measurement volumes are created after beam refraction through the windows. Inlet conditions of the facility have been investigated and fluctuations of the ambient conditions have been mitigated with a large settling chamber to ensure repeatable and stable operation. The current instrumentation was utilized to determine the compressor performance. Measurements of the steady performance parameters along with those of the internal flowfield are documented.

  13. Waste Estimates for a Future Recycling Plant in the US Based Upon AREVA Operating Experience - 13206

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foare, Genevieve; Meze, Florian; Bader, Sven

    2013-07-01

    Estimates of process and secondary wastes produced by a recycling plant built in the U.S., which is composed of a used nuclear fuel (UNF) reprocessing facility and a mixed oxide (MOX) fuel fabrication facility, are performed as part of a U.S. Department of Energy (DOE) sponsored study [1]. In this study, a set of common inputs, assumptions, and constraints were identified to allow for comparison of these wastes between different industrial teams. AREVA produced a model of a reprocessing facility, an associated fuel fabrication facility, and waste treatment facilities to develop the results for this study. These facilities were dividedmore » into a number of discrete functional areas for which inlet and outlet flow streams were clearly identified to allow for an accurate determination of the radionuclide balance throughout the facility and the waste streams. AREVA relied primarily on its decades of experience and feedback from its La Hague (reprocessing) and MELOX (MOX fuel fabrication) commercial operating facilities in France to support this assessment. However, to perform these estimates for a U.S. facility with different regulatory requirements and to take advantage of some technological advancements, such as in the potential treatment of off-gases, some deviations from this experience were necessary. A summary of AREVA's approach and results for the recycling of 800 metric tonnes of initial heavy metal (MTIHM) of LWR UNF per year into MOX fuel under the assumptions and constraints identified for this DOE study are presented. (authors)« less

  14. Measuring the preparedness of health facilities to deliver emergency obstetric care in a South African district.

    PubMed

    Thwala, Siphiwe Bridget Pearl; Blaauw, Duane; Ssengooba, Freddie

    2018-01-01

    Improving the delivery of emergency obstetric care (EmNOC) remains critical in addressing direct causes of maternal mortality. United Nations (UN) agencies have promoted standard methods for evaluating the availability of EmNOC facilities although modifications have been proposed by others. This study presents an assessment of the preparedness of public health facilities to provide EmNOC using these methods in one South African district with a persistently high maternal mortality ratio. Data collection took place in the final quarter of 2014. Cross-sectional surveys were conducted to classify the 7 hospitals and 8 community health centres (CHCs) in the district as either basic EmNOC (BEmNOC) or comprehensive EmNOC (CEmNOC) facilities using UN EmNOC signal functions. The required density of EmNOC facilities was calculated using UN norms. We also assessed the availability of EmNOC personnel, resuscitation equipment, drugs, fluids, and protocols at each facility. The workload of skilled EmNOC providers at hospitals and CHCs was compared. All 7 hospitals in the district were classified as CEmNOC facilities, but none of the 8 CHCs performed all required signal functions to be classified as BEmNOC facilities. UN norms indicated that 25 EmNOC facilities were required for the district population, 5 of which should be CEmNOCs. None of the facilities had 100% of items on the EmNOC checklists. Hospital midwives delivered an average of 36.4±14.3 deliveries each per month compared to only 7.9±3.2 for CHC midwives (p<0.001). The analysis indicated a shortfall of EmNOC facilities in the district. Full EmNOC services were centralised to hospitals to assure patient safety even though national policy guidelines sanction more decentralisation to CHCs. Studies measuring EmNOC availability need to consider facility opening hours, capacity and staffing in addition to the demonstrated performance of signal functions.

  15. Accreditation Status and Geographic Location of Outpatient Echocardiographic Testing Facilities Among Medicare Beneficiaries: The VALUE-ECHO Study.

    PubMed

    Brown, Scott C; Wang, Kefeng; Dong, Chuanhui; Yi, Li; Marinovic Gutierrez, Carolina; Di Tullio, Marco R; Farrell, Mary Beth; Burgess, Pamela; Gornik, Heather L; Hamburg, Naomi M; Needleman, Laurence; Orsinelli, David; Robison, Susana; Rundek, Tatjana

    2018-02-01

    Accreditation of echocardiographic testing facilities by the Intersocietal Accreditation Commission (IAC) is supported by the American College of Cardiology and American Society of Echocardiography. However, limited information exists on the accreditation status and geographic distribution of echocardiographic facilities in the United States. Our study aimed to identify (1) the proportion of outpatient echocardiography facilities used by Medicare beneficiaries that are IAC accredited, (2) their geographic distribution, and (3) variations in procedure type and volume by accreditation status. As part of the VALUE-ECHO (Value of Accreditation, Location, and Utilization Evaluation-Echocardiography) study, we examined the proportion of IAC-accredited echocardiographic facilities performing outpatient echocardiography in the 2013 Centers for Medicare and Medicaid Services outpatient limited data set (100% sample) and their geographic distribution using geocoding in ArcGIS (ESRI, Redlands, CA). Among 4573 outpatient facilities billing Medicare for echocardiographic testing in 2013, 99.6% (n = 4554) were IAC accredited (99.7% in the 50 US states and 86.2% in Puerto Rico). The proportion IAC-accredited echocardiographic facilities varied by region, with 98.7%, 99.9%, 99.9%, 99.5%, and 86.2% of facilities accredited in the Northeast, South, Midwest, West, and Puerto Rico, respectively (P < .01, Fisher exact test). Of all echocardiographic outpatient procedures conducted (n = 1,890,156), 99.8% (n = 1,885,382) were performed in IAC-accredited echocardiographic facilities. Most procedures (90.9%) were transthoracic echocardiograms, of which 99.7% were conducted in IAC-accredited echocardiographic facilities. Almost all outpatient echocardiographic facilities billed by Medicare are IAC accredited. This accreditation rate is substantially higher than previously reported for US outpatient vascular testing facilities (13% IAC accredited). The uniformity of imaging and interpretation protocols from a single accrediting body is important to facilitate optimal cardiovascular care. © 2017 by the American Institute of Ultrasound in Medicine.

  16. Measuring the preparedness of health facilities to deliver emergency obstetric care in a South African district

    PubMed Central

    Blaauw, Duane; Ssengooba, Freddie

    2018-01-01

    Background Improving the delivery of emergency obstetric care (EmNOC) remains critical in addressing direct causes of maternal mortality. United Nations (UN) agencies have promoted standard methods for evaluating the availability of EmNOC facilities although modifications have been proposed by others. This study presents an assessment of the preparedness of public health facilities to provide EmNOC using these methods in one South African district with a persistently high maternal mortality ratio. Methods Data collection took place in the final quarter of 2014. Cross-sectional surveys were conducted to classify the 7 hospitals and 8 community health centres (CHCs) in the district as either basic EmNOC (BEmNOC) or comprehensive EmNOC (CEmNOC) facilities using UN EmNOC signal functions. The required density of EmNOC facilities was calculated using UN norms. We also assessed the availability of EmNOC personnel, resuscitation equipment, drugs, fluids, and protocols at each facility. The workload of skilled EmNOC providers at hospitals and CHCs was compared. Results All 7 hospitals in the district were classified as CEmNOC facilities, but none of the 8 CHCs performed all required signal functions to be classified as BEmNOC facilities. UN norms indicated that 25 EmNOC facilities were required for the district population, 5 of which should be CEmNOCs. None of the facilities had 100% of items on the EmNOC checklists. Hospital midwives delivered an average of 36.4±14.3 deliveries each per month compared to only 7.9±3.2 for CHC midwives (p<0.001). Conclusions The analysis indicated a shortfall of EmNOC facilities in the district. Full EmNOC services were centralised to hospitals to assure patient safety even though national policy guidelines sanction more decentralisation to CHCs. Studies measuring EmNOC availability need to consider facility opening hours, capacity and staffing in addition to the demonstrated performance of signal functions. PMID:29596431

  17. Effectiveness of the WHO SCC on improving adherence to essential practices during childbirth, in resource constrained settings.

    PubMed

    Kumar, Somesh; Yadav, Vikas; Balasubramaniam, Sudharsanam; Jain, Yashpal; Joshi, Chandra Shekhar; Saran, Kailash; Sood, Bulbul

    2016-11-08

    India accounts for 27 % of world's neonatal deaths. Although more Indian women deliver in facilities currently than a decade ago, early neonatal mortality has not declined, likely because of insufficient quality of care. The WHO Safe Childbirth Checklist (SCC) was developed to support health workers to perform essential practices known to reduce preventable maternal and new-born deaths around the time of childbirth. Despite promising early research many outstanding questions remain about effectiveness of the SCC in low-resource settings. In collaboration with the Ministry of Health SCC was modified for Indian context and introduced in 101 intervention facilities in Rajasthan, India and 99 facilities served as comparison to study if it reduces mortality. This Quasi experimental Observational intervention-comparison was embedded in this larger program to test whether a program for introduction of SCC with simple implementation package was associated with increased adherence to 28 evidence-based practices. This study was conducted in 8 intervention and 8 comparison sites. Program interventions to promote appropriate use of the SCC included orienting providers to the checklist, modest modifications of the SCC to promote provider uptake and accountability, ensuring availability of essential supplies, and providing supportive supervision for helping providers in using the SCC. The SCC was used by providers in 86 % of 240 deliveries observed in the eight intervention facilities. Providers in the intervention group significantly adhered to practices included in the SCC than providers in the comparison group controlling for baseline scores and confounders. Women delivering in the intervention facilities received on an average 11.5 more of the 28 practices included compared with women in the comparison facilities. For selected practices provider performance in the intervention group increased as much as 93 % than comparison sites. Use of the SCC and provider performance of best practices increased in intervention facilities reflecting improvement in quality of facility childbirth care for women and new-born in low resource settings.

  18. Ejecta Experiments at the Pegasus Pulsed Power Facility

    DTIC Science & Technology

    1997-06-01

    Laboratory (LANL ). The facility provides both radial and axial access for making measurements. There exist optical, laser , and X-Ray paths for performing...and axial access for making measurements. There exist optical, laser , and X-Ray paths for performing measurements on the target assembly located near...surface variations, microjets can be formed thus contributing to the amount of ejecta. In addition to material properties which contribute to ejecta

  19. DSN Array Simulator

    NASA Technical Reports Server (NTRS)

    Tikidjian, Raffi; Mackey, Ryan

    2008-01-01

    The DSN Array Simulator (wherein 'DSN' signifies NASA's Deep Space Network) is an updated version of software previously denoted the DSN Receive Array Technology Assessment Simulation. This software (see figure) is used for computational modeling of a proposed DSN facility comprising user-defined arrays of antennas and transmitting and receiving equipment for microwave communication with spacecraft on interplanetary missions. The simulation includes variations in spacecraft tracked and communication demand changes for up to several decades of future operation. Such modeling is performed to estimate facility performance, evaluate requirements that govern facility design, and evaluate proposed improvements in hardware and/or software. The updated version of this software affords enhanced capability for characterizing facility performance against user-defined mission sets. The software includes a Monte Carlo simulation component that enables rapid generation of key mission-set metrics (e.g., numbers of links, data rates, and date volumes), and statistical distributions thereof as functions of time. The updated version also offers expanded capability for mixed-asset network modeling--for example, for running scenarios that involve user-definable mixtures of antennas having different diameters (in contradistinction to a fixed number of antennas having the same fixed diameter). The improved version also affords greater simulation fidelity, sufficient for validation by comparison with actual DSN operations and analytically predictable performance metrics.

  20. The used nuclear fuel problem - can reprocessing and consolidated storage be complementary?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, C.; Thomas, I.

    2013-07-01

    This paper describes our CISF (Consolidated Interim Storage Facilities) and Reprocessing Facility concepts and show how they can be combined with a geologic repository to provide a comprehensive system for dealing with spent fuels in the USA. The performance of the CISF was logistically analyzed under six operational scenarios. A 3-stage plan has been developed to establish the CISF. Stage 1: the construction at the CISF site of only a rail receipt interface and storage pad large enough for the number of casks that will be received. The construction of the CISF Canister Handling Facility, the Storage Cask Fabrication Facility,more » the Cask Maintenance Facility and supporting infrastructure are performed during stage 2. The construction and placement into operation of a water-filled pool repackaging facility is completed for Stage 3. By using this staged approach, the capital cost of the CISF is spread over a number of years. It also allows more time for a final decision on the geologic repository to be made. A recycling facility will be built, this facility will used the NUEX recycling process that is based on the aqueous-based PUREX solvent extraction process, using a solvent of tri-N-butyl phosphate in a kerosene diluent. It is capable of processing spent fuels at a rate of 5 MT per day, at burn-ups up to 50 GWD per ton of spent fuels and a minimum of 5 years out-of-reactor cooling.« less

  1. An assessment of the use of antimisting fuel in turbofan engines

    NASA Technical Reports Server (NTRS)

    Fiorentino, A.; Desaro, R.; Franz, T.

    1980-01-01

    The effects of antimisting kerosene on the performance of the components from the fuel system and the combustor of a JT8D aircraft engine were evaluated. The problems associated with antimisting kerosene were identified and the extent of shearing or degradation required to allow the engine components to achieve satisfactory operation were determined. The performance of the combustor was assessed in a high pressure facility and in an altitude relight/cold ignition facility. The performance of the fuel pump and control system was evaluated in an open loop simulation.

  2. DOE LeRC photovoltaic systems test facility

    NASA Technical Reports Server (NTRS)

    Cull, R. C.; Forestieri, A. F.

    1978-01-01

    The facility was designed and built and is being operated as a national facility to serve the needs of the entire DOE National Photovoltaic Program. The object of the facility is to provide a place where photovoltaic systems may be assembled and electrically configured, without specific physical configuration, for operation and testing to evaluate their performance and characteristics. The facility as a breadboard system allows investigation of operational characteristics and checkout of components, subsystems and systems before they are mounted in field experiments or demonstrations. The facility as currently configured consist of 10 kW of solar arrays built from modules, two inverter test stations, a battery storage system, interface with local load and the utility grid, and instrumentation and control necessary to make a flexible operating facility. Expansion to 30 kW is planned for 1978. Test results and operating experience are summaried to show the variety of work that can be done with this facility.

  3. Porous NiCo2O4 nanosheets/reduced graphene oxide composite: facile synthesis and excellent capacitive performance for supercapacitors.

    PubMed

    Ma, Lianbo; Shen, Xiaoping; Ji, Zhenyuan; Cai, Xiaoqing; Zhu, Guoxing; Chen, Kangmin

    2015-02-15

    A composite with porous NiCo2O4 nanosheets attached on reduced graphene oxide (RGO) sheets is synthesized through a facile solution-based method combined with a simple thermal annealing process. The capacitive performances of the as-prepared NiCo2O4/RGO (NCG) composites as electrode materials are investigated. It is found that the NCG composites exhibit a high specific capacitance up to 1186.3 F g(-1) at the current density of 0.5 A g(-1), and superior cycling stability with about 97% of the initial capacitance after 100 cycles. The greatly enhanced capacitive performance of the NCG electrode can be attributed to the existence of RGO support, which serves as both conductive channels and active interface. The approach used in the synthesis provides a facile route for preparing graphene-binary metal oxide electrode materials. The remarkable capacitive performance of NCG composites will undoubtedly make them be attractive for high performance energy storage applications. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Outsourcing strategy and tendering methodology for the operation and maintenance of CERN’s cryogenic facilities

    NASA Astrophysics Data System (ADS)

    Serio, L.; Bremer, J.; Claudet, S.; Delikaris, D.; Ferlin, G.; Ferrand, F.; Pezzetti, M.; Pirotte, O.

    2017-12-01

    CERN operates and maintains the world largest cryogenic infrastructure ranging from ageing but well maintained installations feeding detectors, test facilities and general services, to the state-of-the-art cryogenic system serving the flagship LHC machine complex. A study was conducted and a methodology proposed to outsource to industry the operation and maintenance of the whole cryogenic infrastructure. The cryogenic installations coupled to non LHC-detectors, test facilities and general services infrastructure have been fully outsourced for operation and maintenance on the basis of performance obligations. The contractor is responsible for the operational performance of the installations based on a yearly operation schedule provided by CERN. The maintenance of the cryogenic system serving the LHC machine and its detectors has been outsourced on the basis of tasks oriented obligations, monitored by key performance indicators. CERN operation team, with the support of the contractor operation team, remains responsible for the operational strategy and performances. We report the analysis, strategy, definition of the requirements and technical specifications as well as the achieved technical and economic performances after one year of operation.

  5. 40 CFR 60.660 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... maximum production rate at which the affected facility will be operated, or 180 days after the initial... less methane and ethane. This emission limit reflects the performance of BDT.] [55 FR 26942, June 29...

  6. 40 CFR 60.660 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... maximum production rate at which the affected facility will be operated, or 180 days after the initial... less methane and ethane. This emission limit reflects the performance of BDT.] [55 FR 26942, June 29...

  7. Pure Air`s Bailly scrubber: A four-year retrospective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manavi, G.B.; Vymazal, D.C.; Sarkus, T.A.

    1997-12-31

    Pure Air`s Advanced Flue Gas Desulfurization (AFGD) Clean Coal Project has completed four highly successful years of operation at NIPSCO`s Bailly Station. As part of their program, Pure Air has concluded a six-part study of system performance. This paper summarizes the results of the demonstration program, including AFGD performance on coals ranging from 2.0--2.4% sulfur. The paper highlights novel aspects of the Bailly facility, including pulverized limestone injection, air rotary sparger for oxidation, wastewater evaporation system and the production of PowerChip{reg_sign} gypsum. Operations and maintenance which have led to the facility`s notable 99.47% availability record are also discussed. A projectmore » company, Pure Air on the Lake Limited Partnership, owns the AFGD facility. Pure Air was the turn key contractor and Air Products and Chemicals, Inc. is the operator of the AFGD system.« less

  8. Improved Cryogenic Optical Test Capability at Marshall Space Flight Center's X-ray Cryogenic Test Facility

    NASA Technical Reports Server (NTRS)

    Kegley, Jeffrey; Haight, Harlan; Hogue, William; Carpenter, Jay; Siler, Richard; Wright, Ernie; Eng, Ron; Baker, Mark; McCracken, Jeff

    2005-01-01

    Marshall Space Flight Center's X-ray & Cryogenic Test Facility (XRCF) has been performing optical wavefront testing and thermal structural deformation testing at subliquid nitrogen cryogenic temperatures since 1999. Recent modifications have been made to the facility in support of the James Webb Space Telescope (JWST) program. The test article envelope and the chamber's refrigeration capacity have both been increased. A new larger helium-cooled enclosure has been added to the existing enclosure increasing both the cross-sectional area and the length. This new enclosure is capable of supporting six JWST Primary Mirror Segment Assemblies. A second helium refrigeration system has been installed essentially doubling the cooling capacity available at the facility. Modifications have also been made to the optical instrumentation area. Improved access is now available for both the installation and operation of optical instrumentation outside the vacuum chamber. Chamber configuration, specifications, and performance data will be presented.

  9. Veterans Affairs facility performance on Washington Circle indicators and casemix-adjusted effectiveness.

    PubMed

    Harris, Alex H S; Humphreys, Keith; Finney, John W

    2007-12-01

    Self-administered Addiction Severity Index (ASI) data were collected on 5,723 patients who received substance abuse treatment in 1 of 110 programs located at 73 Veterans Affairs facilities. The associations between each of three Washington Circle (WC) performance indicator scores (identification, initiation, and engagement) and their casemix-adjusted facility-level improvement in ASI drug and alcohol composites 7 months after intake were estimated. Higher initiation rates were not associated with facility-level improvement in ASI alcohol composite scores but were modestly associated with greater improvements in ASI drug composite scores. Identification and engagement rates were unrelated to 7-month outcomes. WC indicators focused on the early stages of treatment may tap necessary but insufficient processes for patients with substance use disorder to achieve good posttreatment outcomes. Ideally, the WC indicators would be supplemented with other measures of treatment quality.

  10. The International Microgravity Laboratory, a Spacelab for materials and life sciences

    NASA Technical Reports Server (NTRS)

    Snyder, Robert S.

    1992-01-01

    The material science experiments performed on the International Microgravity Laboratory (IML-1), which is used to perform investigations which require the low gravity environment of space, are discussed. These experiments, the principal investigator, and associated organization are listed. Whether the experiment was a new development or was carried on an earlier space mission, such as the third Spacelab (SL-3) or the Shuttle Middeck, is also noted. The two major disciplines of materials science represented on IML-1 were the growth of crystals from the melt, solution, or vapor and the study of fluids (liquids and gases) in a reduced gravity environment. The various facilities on board IML-1 and their related experiments are described. The facilities include the Fluids Experiment System (FES) Vapor Crystal Growth System (VCGS) Organic Crystal Growth Facility (OCGF), Cryostat (CRY), and the Critical Point Facility (CPF).

  11. Practical Approaches for Assessment of Daily and Post-discharge Room Disinfection in Healthcare Facilities.

    PubMed

    Deshpande, Abhishek; Donskey, Curtis J

    2017-09-01

    Cleaning and disinfection in healthcare facilities is essential to ensure patient safety. This review examines practical strategies used to assess and improve the effectiveness of daily and post-discharge manual cleaning in healthcare facilities. Effective implementation of cleaning interventions requires objective monitoring of staff performance with regular feedback on performance. Use of fluorescent markers to assess thoroughness of cleaning and measurement of residual ATP can provide rapid and objective feedback to personnel and have been associated with improved cleaning. Direct observation of cleaning and interviews with front-line staff are useful to identify variations and deficiencies in practice that may not be detected by other methods. Although not recommended for routine monitoring, cultures can be helpful for outbreak investigations. Monitoring and feedback can be effective in improving cleaning and disinfection in healthcare facilities. Ongoing commitment within institutions is needed to sustain successful cleaning and disinfection programs.

  12. Simulation of the neutron flux in the irradiation facility at RA-3 reactor.

    PubMed

    Bortolussi, S; Pinto, J M; Thorp, S I; Farias, R O; Soto, M S; Sztejnberg, M; Pozzi, E C C; Gonzalez, S J; Gadan, M A; Bellino, A N; Quintana, J; Altieri, S; Miller, M

    2011-12-01

    A facility for the irradiation of a section of patients' explanted liver and lung was constructed at RA-3 reactor, Comisión Nacional de Energía Atómica, Argentina. The facility, located in the thermal column, is characterized by the possibility to insert and extract samples without the need to shutdown the reactor. In order to reach the best levels of security and efficacy of the treatment, it is necessary to perform an accurate dosimetry. The possibility to simulate neutron flux and absorbed dose in the explanted organs, together with the experimental dosimetry, allows setting more precise and effective treatment plans. To this end, a computational model of the entire reactor was set-up, and the simulations were validated with the experimental measurements performed in the facility. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Safety analysis, 200 Area, Savannah River Plant: Separations area operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, W.C.; Lee, R.; Allen, P.M.

    1991-07-01

    The nev HB-Line, located on the fifth and sixth levels of Building 221-H, is designed to replace the aging existing HB-Line production facility. The nev HB-Line consists of three separate facilities: the Scrap Recovery Facility, the Neptunium Oxide Facility, and the Plutonium Oxide Facility. There are three separate safety analyses for the nev HB-Line, one for each of the three facilities. These are issued as supplements to the 200-Area Safety Analysis (DPSTSA-200-10). These supplements are numbered as Sup 2A, Scrap Recovery Facility, Sup 2B, Neptunium Oxide Facility, Sup 2C, Plutonium Oxide Facility. The subject of this safety analysis, the, Plutoniummore » Oxide Facility, will convert nitrate solutions of {sup 238}Pu to plutonium oxide (PuO{sub 2}) powder. All these new facilities incorporate improvements in: (1) engineered barriers to contain contamination, (2) barriers to minimize personnel exposure to airborne contamination, (3) shielding and remote operations to decrease radiation exposure, and (4) equipment and ventilation design to provide flexibility and improved process performance.« less

  14. National space test centers - Lewis Research Center Facilities

    NASA Technical Reports Server (NTRS)

    Roskilly, Ronald R.

    1990-01-01

    The Lewis Research Center, NASA, presently has a number of test facilities that constitute a significant national space test resource. It is expected this capability will continue to find wide application in work involving this country's future in space. Testing from basic research to applied technology, to systems development, to ground support will be performed, supporting such activities as Space Station Freedom, the Space Exploration Initiative, Mission to Planet Earth, and many others. The major space test facilities at both Cleveland and Lewis' Plum Brook Station are described. Primary emphasis is on space propulsion facilities; other facilities of importance in space power and microgravity are also included.

  15. The Ferrara hard X-ray facility for testing/calibrating hard X-ray focusing telescopes

    NASA Astrophysics Data System (ADS)

    Loffredo, Gianluca; Frontera, Filippo; Pellicciotta, Damiano; Pisa, Alessandro; Carassiti, Vito; Chiozzi, Stefano; Evangelisti, Federico; Landi, Luca; Melchiorri, Michele; Squerzanti, Stefano

    2005-12-01

    We will report on the current configuration of the X-ray facility of the University of Ferrara recently used to perform reflectivity tests of mosaic crystals and to calibrate the experiment JEM X aboard Integral. The facility is now located in the technological campus of the University of Ferrara in a new building (named LARIX laboratory= LARge Italian X-ray facility) that includes a tunnel 100 m long with, on the sides, two large experimental rooms. The facility is being improved for determining the optical axis of mosaic crystals in Laue configuration, for calibrating Laue lenses and hard X-ray mirror prototypes.

  16. Design data package and operating procedures for MSFC solar simulator test facility

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Design and operational data for the solar simulator test facility are reviewed. The primary goal of the facility is to evaluate the performance capacibility and worst case failure modes of collectors, which utilize either air or liquid transport media. The facility simulates environmental parameters such as solar radiation intensity, solar spectrum, collimation, uniformity, and solar attitude. The facility also simulates wind conditions of velocity and direction, solar system conditions imposed on the collector, collector fluid inlet temperature, and geometric factors of collector tilt and azimuth angles. Testing the simulator provides collector efficiency data, collector time constant, incident angle modifier data, and stagnation temperature values.

  17. Current status and some future test directions for the U.S. National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Gloss, Blair B.

    1992-01-01

    The construction of the National Transonic Facility was completed in September 1982 and the start-up and checkout of the tunnel systems were performed over the following two years. In August 1984, the facility was declared operational for final checkout of cryogenic instrumentation and control systems, and for the aerodynamics calibration and testing to commence. Since 1984 several operational problems have been identified and successfully solved which is demonstrated by the fact that the facility has operated the last year with no significant facility down times. Also during this time period, development of test techniques and instrumentation has continued. This paper will review some of the recent test techniques and instrumentation developments, and will briefly review the status of the facility.

  18. State machine analysis of sensor data from dynamic processes

    DOEpatents

    Cook, William R.; Brabson, John M.; Deland, Sharon M.

    2003-12-23

    A state machine model analyzes sensor data from dynamic processes at a facility to identify the actual processes that were performed at the facility during a period of interest for the purpose of remote facility inspection. An inspector can further input the expected operations into the state machine model and compare the expected, or declared, processes to the actual processes to identify undeclared processes at the facility. The state machine analysis enables the generation of knowledge about the state of the facility at all levels, from location of physical objects to complex operational concepts. Therefore, the state machine method and apparatus may benefit any agency or business with sensored facilities that stores or manipulates expensive, dangerous, or controlled materials or information.

  19. 10 CFR Appendix U to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Test Procedure,” and Chapter 6, “Definitions and Acronyms,” of the EPA's “ENERGY STAR Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR... specified in Chapter 4, “Equipment Setup and Test Procedure,” of the EPA's “ENERGY STAR Testing Facility...

  20. 10 CFR Appendix U to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Test Procedure,” and Chapter 6, “Definitions and Acronyms,” of the EPA's “ENERGY STAR Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR... specified in Chapter 4, “Equipment Setup and Test Procedure,” of the EPA's “ENERGY STAR Testing Facility...

Top