Sample records for coached 4d ct

  1. Analysis of Carina Position as Surrogate Marker for Delivering Phase-Gated Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weide, Lineke van der; Soernsen de Koste, John R. van; Lagerwaard, Frank J.

    2008-07-15

    Purpose: Respiratory gating can mitigate the effect of tumor mobility in radiotherapy (RT) for lung cancer. Because the tumor is generally not visualized, external surrogates of tumor position are used to trigger respiration-gated RT. We evaluated the suitability of the carina position as a surrogate in respiration-gated RT. Methods and Materials: A total of 30 four-dimensional (4D) computed tomography (CT) scans from 14 patients with lung cancer were retrospectively analyzed. Both uncoached (free breathing) and audio-coached 4D-CT scans were acquired from 9 patients, and 12 uncoached 4D-CT scans were acquired from 5 other patients during a 2-4-week period of stereotacticmore » RT. The repeat scans were co-registered. The carina position was identified on the coronal cut planes in all 4D-CT phases. The correlation between the carina position and the total lung volume for each phase was determined, and the reproducibility of the carina position was studied in the 5 patients with repeat uncoached 4D-CT scans. Results: The mean extent of carina motion in 21 uncoached scans was 5.3 {+-} 1.6 mm in the craniocaudal (CC), 2.3 {+-} 1.4 mm in the anteroposterior, and 1.5 {+-} 0.7 mm in the mediolateral direction. Audio coaching resulted in a twofold increase in carina mobility in all directions. The CC carina position correlated with changes in the total lung volume (R = 0.89 {+-} 0.14), but the correlation was better for the audio-coached than for the uncoached 4D-CT scans (R = 0.93 {+-} 0.08 vs. R = 0.85 {+-} 0.17; paired t test, p = 0.034). Preliminary data from the 5 patients indicated that the CC carina motion correlated better with tumor motion than did the motion of the diaphragm. Conclusions: The CC position of the carina correlated well with the total lung volume, indicating that the carina is a good surrogate for verifying the total lung volume during respiration-gated RT.« less

  2. Gas turbine engines and transmissions for bus demonstration programs. Technical status report, 31 October 1979-31 January 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigro, D.N.

    1980-02-01

    Progress is reported on the procurement and delivery of 11 Allison GT 404-4 Industrial Gas Turbine Engines and 5 HT740CT and 6 V730CT Allison Automatic Transmissions for the Greyhound and Transit Coaches, respectively. Ceramic regenerators have been incorporated in the build configuration for last 4 Transit Coach engines. The 5 Greyhound Coach engines and the first 2 Transit Coach engines were built in the all-metal configuration. The Master Schedules for the program are presented.

  3. SU-E-J-55: End-To-End Effectiveness Analysis of 3D Surface Image Guided Voluntary Breath-Holding Radiotherapy for Left Breast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, M; Feigenberg, S

    Purpose To evaluate the effectiveness of using 3D-surface-image to guide breath-holding (BH) left-side breast treatment. Methods Two 3D surface image guided BH procedures were implemented and evaluated: normal-BH, taking BH at a comfortable level, and deep-inspiration-breath-holding (DIBH). A total of 20 patients (10 Normal-BH and 10 DIBH) were recruited. Patients received a BH evaluation using a commercialized 3D-surface- tracking-system (VisionRT, London, UK) to quantify the reproducibility of BH positions prior to CT scan. Tangential 3D/IMRT plans were conducted. Patients were initially setup under free-breathing (FB) condition using the FB surface obtained from the untaged CT to ensure a correct patientmore » position. Patients were then guided to reach the planned BH position using the BH surface obtained from the BH CT. Action-levels were set at each phase of treatment process based on the information provided by the 3D-surface-tracking-system for proper interventions (eliminate/re-setup/ re-coaching). We reviewed the frequency of interventions to evaluate its effectiveness. The FB-CBCT and port-film were utilized to evaluate the accuracy of 3D-surface-guided setups. Results 25% of BH candidates with BH positioning uncertainty > 2mm are eliminated prior to CT scan. For >90% of fractions, based on the setup deltas from3D-surface-trackingsystem, adjustments of patient setup are needed after the initial-setup using laser. 3D-surface-guided-setup accuracy is comparable as CBCT. For the BH guidance, frequency of interventions (a re-coaching/re-setup) is 40%(Normal-BH)/91%(DIBH) of treatments for the first 5-fractions and then drops to 16%(Normal-BH)/46%(DIBH). The necessity of re-setup is highly patient-specific for Normal-BH but highly random among patients for DIBH. Overall, a −0.8±2.4 mm accuracy of the anterior pericardial shadow position was achieved. Conclusion 3D-surface-image technology provides effective intervention to the treatment process and ensures favorable day-to-day setup accuracy. DIBH setup appears to be more uncertain and this would be the patient group who will definitely benefit from the extra information of 3D surface setup.« less

  4. An Evaluation of Two Internal Surrogates for Determining the Three-Dimensional Position of Peripheral Lung Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spoelstra, Femke; Soernsen de Koste, John R. van; Vincent, Andrew

    2009-06-01

    Purpose: Both carina and diaphragm positions have been used as surrogates during respiratory-gated radiotherapy. We studied the correlation of both surrogates with three-dimensional (3D) tumor position. Methods and Materials: A total of 59 repeat artifact-free four-dimensional (4D) computed tomography (CT) scans, acquired during uncoached breathing, were identified in 23 patients with Stage I lung cancer. Repeat scans were co-registered to the initial 4D CT scan, and tumor, carina, and ipsilateral diaphragm were manually contoured in all phases of each 4D CT data set. Correlation between positions of carina and diaphragm with 3D tumor position was studied by use of log-likelihoodmore » ratio statistics. Models to predict 3D tumor position from internal surrogates at end inspiration (EI) and end expiration (EE) were developed, and model accuracy was tested by calculating SDs of differences between predicted and actual tumor positions. Results: Motion of both the carina and diaphragm significantly correlated with tumor motion, but log-likelihood ratios indicated that the carina was more predictive for tumor position. When craniocaudal tumor position was predicted by use of craniocaudal carina positions, the SDs of the differences between the predicted and observed positions were 2.2 mm and 2.4 mm at EI and EE, respectively. The corresponding SDs derived with the diaphragm positions were 3.7 mm and 3.9 mm at EI and EE, respectively. Prediction errors in the other directions were comparable. Prediction accuracy was similar at EI and EE. Conclusions: The carina is a better surrogate of 3D tumor position than diaphragm position. Because residual prediction errors were observed in this analysis, additional studies will be performed using audio-coached scans.« less

  5. Gas turbine engines and transmissions for bus demonstration programs. Technical status report, 30 April 1979-31 July 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigro, D.N.

    1979-07-01

    The quarterly status report covers the period from 30 April 1979 through 31 July 1979 and is a summary of DDA activities for the effort performed on the procurement and delivery of eleven (11) Allison GT 404-4 gas turbine engines and five (5) HT740CT and six (6) V730CT Allison automatic transmissions and the required associated software. The contract requires the delivery of eleven (11) Allison GT 404-4 Industrial Gas Turbine Engines and five (5) HT740CT and six (6) V730CT Allison Automatic Transmissions for the Greyhound and Transit Coaches, respectively. In addition, software items such as cost reports, technical reports, installationmore » drawings, acceptance test data and parts lists are required. A recent decision by the DOE will modify the build configuration for the last four (4) Transit Coach engines. It was decided by the DOE at a meeting in Washington, DC on March 28, 1979 with representatives from DDA, NASA/LeRC, JPL and Booz-Allen and Hamilton that these engines will be built with ceramic regenerators. (TFD)« less

  6. Comprehensive Surgical Coaching Enhances Surgical Skill in the Operating Room: A Randomized Controlled Trial.

    PubMed

    Bonrath, Esther M; Dedy, Nicolas J; Gordon, Lauren E; Grantcharov, Teodor P

    2015-08-01

    The aim of the study was to determine whether individualized coaching improved surgical technical skill in the operating room to a higher degree than current residency training. Clinical training in the operating room is a valuable opportunity for surgeons to acquire skill and knowledge; however, it often remains underutilized. Coaching has been successfully used in various industries to enhance performance, but its role in surgery has been insufficiently investigated. This randomized controlled trial was conducted at one surgical training program. Trainees undergoing a minimally invasive surgery rotation were randomized to either conventional training (CT) or comprehensive surgical coaching (CSC). CT included ward and operating room duties, and regular departmental teaching sessions. CSC comprised performance analysis, debriefing, feedback, and behavior modeling. Primary outcome measures were technical performance as measured on global and procedure-specific rating scales, and surgical safety parameters, measured by error count. Operative performance was assessed by blinded video analysis of the first and last cases recorded by the participants during their rotation. Twenty residents were randomized and 18 completed the study. At posttraining the CSC group (n = 9) scored significantly higher on a procedure-specific skill scale compared with the CT group (n = 9) [median, 3.90 (interquartile range, 3.68-4.30) vs 3.60 (2.98-3.70), P = 0.017], and made fewer technical errors [10 (7-13) vs 18 (13-21), P = 0.003]. Significant within-group improvements for all skill metrics were only noted in the CSC group. Comprehensive surgical coaching enhances surgical training and results in skill acquisition superior to conventional training.

  7. A New Method for the Evaluation and Prediction of Base Stealing Performance.

    PubMed

    Bricker, Joshua C; Bailey, Christopher A; Driggers, Austin R; McInnis, Timothy C; Alami, Arya

    2016-11-01

    Bricker, JC, Bailey, CA, Driggers, AR, McInnis, TC, and Alami, A. A new method for the evaluation and prediction of base stealing performance. J Strength Cond Res 30(11): 3044-3050, 2016-The purposes of this study were to evaluate a new method using electronic timing gates to monitor base stealing performance in terms of reliability, differences between it and traditional stopwatch-collected times, and its ability to predict base stealing performance. Twenty-five healthy collegiate baseball players performed maximal effort base stealing trials with a right and left-handed pitcher. An infrared electronic timing system was used to calculate the reaction time (RT) and total time (TT), whereas coaches' times (CT) were recorded with digital stopwatches. Reliability of the TGM was evaluated with intraclass correlation coefficients (ICCs) and coefficient of variation (CV). Differences between the TGM and traditional CT were calculated with paired samples t tests Cohen's d effect size estimates. Base stealing performance predictability of the TGM was evaluated with Pearson's bivariate correlations. Acceptable relative reliability was observed (ICCs 0.74-0.84). Absolute reliability measures were acceptable for TT (CVs = 4.4-4.8%), but measures were elevated for RT (CVs = 32.3-35.5%). Statistical and practical differences were found between TT and CT (right p = 0.00, d = 1.28 and left p = 0.00, d = 1.49). The TGM TT seems to be a decent predictor of base stealing performance (r = -0.49 to -0.61). The authors recommend using the TGM used in this investigation for athlete monitoring because it was found to be reliable, seems to be more precise than traditional CT measured with a stopwatch, provides an additional variable of value (RT), and may predict future performance.

  8. Gas turbine engines and transmissions for bus demonstration programs. Technical status report, 31 July 1979--31 October 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigro, D.N.

    1979-11-01

    The report summarizes the DDA activities for the effort performed on the procurement and delivery of eleven Allison GT 404-4 gas turbine engines and five HT740CT and six V730CT Allison automatic transmissions and the required associated software. The contract requires the delivery of the engines and transmissions for the Greyhound and Transit Coaches, respectively. In addition, software items such as cost reports, technical reports, installation drawings, acceptance test data and parts lists are required. A recent decision by the DOE will modify the build configuration for the last four (4) Transit Coach engines. It was decided by the DOE atmore » a meeting in Washington, DC on March 28, 1979 with representatives from DDA, NASA/LeRC, JPL and Booz-Allen and Hamilton that these engines are to be built with ceramic regenerators. (TFD)« less

  9. Evaluation of Fractional Regional Ventilation Using 4D-CT and Effects of Breathing Maneuvers on Ventilation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mistry, Nilesh N., E-mail: nmistry@som.umaryland.edu; Diwanji, Tejan; Shi, Xiutao

    2013-11-15

    Purpose: Current implementations of methods based on Hounsfield units to evaluate regional lung ventilation do not directly incorporate tissue-based mass changes that occur over the respiratory cycle. To overcome this, we developed a 4-dimensional computed tomography (4D-CT)-based technique to evaluate fractional regional ventilation (FRV) that uses an individualized ratio of tidal volume to end-expiratory lung volume for each voxel. We further evaluated the effect of different breathing maneuvers on regional ventilation. The results from this work will help elucidate the relationship between global and regional lung function. Methods and Materials: Eight patients underwent 3 sets of 4D-CT scans during 1more » session using free-breathing, audiovisual guidance, and active breathing control. FRV was estimated using a density-based algorithm with mass correction. Internal validation between global and regional ventilation was performed by use of the imaging data collected during the use of active breathing control. The impact of breathing maneuvers on FRV was evaluated comparing the tidal volume from 3 breathing methods. Results: Internal validation through comparison between the global and regional changes in ventilation revealed a strong linear correlation (slope of 1.01, R{sup 2} of 0.97) between the measured global lung volume and the regional lung volume calculated by use of the “mass corrected” FRV. A linear relationship was established between the tidal volume measured with the automated breathing control system and FRV based on 4D-CT imaging. Consistently larger breathing volumes were observed when coached breathing techniques were used. Conclusions: The technique presented improves density-based evaluation of lung ventilation and establishes a link between global and regional lung ventilation volumes. Furthermore, the results obtained are comparable with those of other techniques of functional evaluation such as spirometry and hyperpolarized-gas magnetic resonance imaging. These results were demonstrated on retrospective analysis of patient data, and further research using prospective data is under way to validate this technique against established clinical tests.« less

  10. Individually optimized contrast-enhanced 4D-CT for radiotherapy simulation in pancreatic ductal adenocarcinoma

    PubMed Central

    Xue, Ming; Lane, Barton F.; Kang, Min Kyu; Patel, Kruti; Regine, William F.; Klahr, Paul; Wang, Jiahui; Chen, Shifeng; D’Souza, Warren; Lu, Wei

    2016-01-01

    Purpose: To develop an individually optimized contrast-enhanced (CE) 4D-computed tomography (CT) for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). Methods: Ten PDA patients were enrolled. Each underwent three CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT using test injection. Three physicians contoured the tumor and pancreatic tissues. Image quality scores, tumor volume, motion, tumor-to-pancreas contrast, and contrast-to-noise ratio (CNR) were compared in the three CTs. Interobserver variations were also evaluated in contouring the tumor using simultaneous truth and performance level estimation. Results: Average image quality scores for CE 3D-CT and CE 4D-CT were comparable (4.0 and 3.8, respectively; P = 0.082), and both were significantly better than that for 4D-CT (2.6, P < 0.001). Tumor-to-pancreas contrast results were comparable in CE 3D-CT and CE 4D-CT (15.5 and 16.7 Hounsfield units (HU), respectively; P = 0.21), and the latter was significantly higher than in 4D-CT (9.2 HU, P = 0.001). Image noise in CE 3D-CT (12.5 HU) was significantly lower than in CE 4D-CT (22.1 HU, P = 0.013) and 4D-CT (19.4 HU, P = 0.009). CNRs were comparable in CE 3D-CT and CE 4D-CT (1.4 and 0.8, respectively; P = 0.42), and both were significantly better in 4D-CT (0.6, P = 0.008 and 0.014). Mean tumor volumes were significantly smaller in CE 3D-CT (29.8 cm3, P = 0.03) and CE 4D-CT (22.8 cm3, P = 0.01) than in 4D-CT (42.0 cm3). Mean tumor motion was comparable in 4D-CT and CE 4D-CT (7.2 and 6.2 mm, P = 0.17). Interobserver variations were comparable in CE 3D-CT and CE 4D-CT (Jaccard index 66.0% and 61.9%, respectively) and were worse for 4D-CT (55.6%) than CE 3D-CT. Conclusions: CE 4D-CT demonstrated characteristics comparable to CE 3D-CT, with high potential for simultaneously delineating the tumor and quantifying tumor motion with a single scan. PMID:27782710

  11. How to Measure Coach Burnout: An Evaluation of Three Burnout Measures

    ERIC Educational Resources Information Center

    Lundkvist, Erik; Stenling, Andreas; Gustafsson, Henrik; Hassmén, Peter

    2014-01-01

    Although coach burnout has been studied for 30 years, what measure to use in this context has not yet been problematized. This study focuses on evaluating convergent and discriminant validity of three coach burnout measures by using multi-trait/multi-method analysis (CT-C[M-1]) model. We choose Maslach Burnout Inventory (MBI), the two dimensional…

  12. SU-E-J-187: Individually Optimized Contrast-Enhancement 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xue, M; Patel, K; Regine, W

    2014-06-01

    Purpose: To study the feasibility of individually optimized contrastenhancement (CE) 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. To evaluate the image quality and contrast enhancement of tumor in the CE 4D-CT, compared to the clinical standard of CE 3D-CT and 4D-CT. Methods: In this IRB-approved study, each of the 7 PDA patients enrolled underwent 3 CT scans: a free-breathing 3D-CT with contrast (CE 3D-CT) followed by a 4D-CT without contrast (4D-CT) in the first study session, and a 4D-CT with individually synchronized contrast injection (CE 4D-CT) in the second study session. In CE 4D-CT, the time of full contrastmore » injection was determined based on the time of peak enhancement for the test injection, injection rate, table speed, and longitudinal location and span of the pancreatic region. Physicians contoured both the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (end-of-exhalation for 4D-CT). The contrast between the tumor and normal pancreatic tissue was computed as the difference of the mean enhancement level of three 1 cm3 regions of interests in T and P, respectively. Wilcoxon rank sum test was used to statistically compare the scores and contrasts. Results: In qualitative evaluations, both CE 3D-CT and CE 4D-CT scored significantly better than 4D-CT (4.0 and 3.6 vs. 2.6). There was no significant difference between CE 3D-CT and CE 4D-CT. In quantitative evaluations, the contrasts between the tumor and the normal pancreatic parenchyma were 0.6±23.4, −2.1±8.0, and −19.6±28.8 HU, in CE 3D-CT, 4D-CT, and CE 4D-CT, respectively. Although not statistically significant, CE 4D-CT achieved better contrast enhancement between the tumor and the normal pancreatic parenchyma than both CE 3D-CT and 4DCT. Conclusion: CE 4D-CT achieved equivalent image quality and better contrast enhancement between tumor and normal pancreatic parenchyma than the clinical standard of CE 3D-CT and 4D-CT. This study was supported in part by Philips Healthcare.« less

  13. TH-EF-BRA-04: Individually Optimized Contrast-Enhanced 4D-CT for Radiotherapy Simulation in Pancreatic Ductal Adenocarcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, W; Xue, M; Lane, B

    Purpose: To develop an individually optimized contrast-enhanced (CE) 4D-CT for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). Methods: Ten PDA patients were enrolled. Each underwent 3 CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT using test injection. Three physicians contoured the tumor and pancreatic tissues. We compared image quality scores, tumor volume, motion, tumor-to-pancreas contrast, and contrast-to-noise ratio (CNR) in the 3 CTs. We also evaluated interobserver variations in contouring the tumor using simultaneous truth and performance level estimation (STAPLE). Results: Average image quality scores for CE 3DCT and CE 4D-CT were comparablemore » (4.0 and 3.8, respectively; P=0.47), and both were significantly better than that for 4D-CT (2.6, P<0.001). Tumor-to-pancreas contrast results were comparable in CE 3D-CT and CE 4D-CT (15.5 and 16.7 HU, respectively; P=0.71), and the latter was significantly higher than in 4D-CT (9.2 HU, P=0.03). Image noise in CE 3D-CT (12.5 HU) was significantly lower than in CE 4D-CT (22.1 HU, P<0.001) and 4D-CT (19.4 HU, P=0.005). CNRs were comparable in CE 3D-CT and CE 4DCT (1.4 and 0.8, respectively; P=0.23), and the former was significantly better than in 4D-CT (0.6, P = 0.04). Mean tumor volumes were smaller in CE 3D-CT (29.8 cm{sup 3}) and CE 4D-CT (22.8 cm{sup 3}) than in 4D-CT (42.0 cm{sup 3}), although these differences were not statistically significant. Mean tumor motion was comparable in 4D-CT and CE 4D-CT (7.2 and 6.2 mm, P=0.23). Interobserver variations were comparable in CE 3D-CT and CE 4D-CT (Jaccard index 66.0% and 61.9%, respectively) and were worse for 4D-CT (55.6%) than CE 3D-CT. Conclusion: CE 4D-CT demonstrated characteristics comparable to CE 3D-CT, with high potential for simultaneously delineating the tumor and quantifying tumor motion with a single scan. Supported in part by Philips Healthcare.« less

  14. SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, W; Xue, M; Patel, K

    2015-06-15

    Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) andmore » the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.« less

  15. Impact of neuromuscular fatigue on match exercise intensity and performance in elite Australian football.

    PubMed

    Mooney, Mitchell G; Cormack, Stuart; Oʼbrien, Brendan J; Morgan, William M; McGuigan, Mike

    2013-01-01

    This study aimed to quantify the influence of neuromuscular fatigue (NMF) via flight time to contraction time ratio (FT:CT) obtained from a countermovement jump (CMJ) on the relationships between yo-yo intermittent recovery (level 2) test (yo-yo IR2), match exercise intensity (high-intensity running [HIR] m·min(-1) and Load·min(-1)) and Australian football (AF) performance. Thirty-seven data sets were collected from 17 different players across 22 elite AF matches. Each data set comprised an athlete's yo-yo IR2 score before the start of the season, match exercise intensity via global positioning system and on-field performance rated by coaches' votes and number of ball disposals. Each data set was categorized as normal (>92% baseline FT:CT, n = 20) or fatigued (<92% baseline FT:CT, n = 17) from a single CMJ performed 96 hours after the previous match. Moderation-mediation analysis was completed with yo-yo IR2 (independent variable), match exercise intensity (mediator), and AF performance (dependent variable) with NMF status as the conditional variable. Isolated interactions between variables were analyzed by Pearson's correlation and effect size statistics. The Yo-yo IR2 score showed an indirect influence on the number of ball disposals via HIR m·min(-1) regardless of NMF status (normal FT:CT indirect effect = 0.019, p < 0.1, reduced FT:CT indirect effect = 0.022, p < 0.1). However, the yo-yo IR2 score only influenced coaches' votes via Load·min(-1) in the nonfatigued state (normal: FT:CT indirect effect = 0.007, p <0.1, reduced: FT:CT indirect effect = -0.001, p > 0.1). In isolation, NMF status also reduces relationships between yo-yo IR2 and load·min(-1), yo-yo IR2 and coaches votes, Load·min(-1) and coaches' votes (Δr > 0.1). Routinely testing yo-yo IR2 capacity, NMF via FT:CT and monitoring Load·min(-1) in conjunction with HIR m·min(-1) as exercise intensity measures in elite AF is recommended.

  16. Helical 4D CT and Comparison with Cine 4D CT

    NASA Astrophysics Data System (ADS)

    Pan, Tinsu

    4D CT was one of the most important developments in radiation oncology in the last decade. Its early development in single slice CT and commercialization in multi-slice CT has radically changed our practice in radiation treatment of lung cancer, and has enabled the stereotactic radiosurgery of early stage lung cancer. In this chapter, we will document the history of 4D CT development, detail the data sufficiency condition governing the 4D CT data collection; present the design of the commercial helical 4D CTs from Philips and Siemens; compare the differences between the helical 4D CT and the GE cine 4D CT in data acquisition, slice thickness, acquisition time and work flow; review the respiratory monitoring devices; and understand the causes of image artifacts in 4D CT.

  17. Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT.

    PubMed

    Pan, Tinsu

    2005-02-01

    We proposed a data sufficiency condition (DSC) for four-dimensional-CT (4D-CT) imaging on a multislice CT scanner, designed a pitch factor for a helical 4D-CT, and compared the acquisition time, slice sensitivity profile (SSP), effective dose, ability to cope with an irregular breathing cycle, and gating technique (retrospective or prospective) of the helical 4D-CT and the cine 4D-CT on the General Electric (GE) LightSpeed RT (4-slice), Plus (4-slice), Ultra (8-slice) and 16 (16-slice) multislice CT scanners. To satisfy the DSC, a helical or cine 4D-CT acquisition has to collect data at each location for the duration of a breathing cycle plus the duration of data acquisition for an image reconstruction. The conditions for the comparison were 20 cm coverage in the cranial-caudal direction, a 4 s breathing cycle, and half-scan reconstruction. We found that the helical 4D-CT has the advantage of a shorter scan time that is 10% shorter than that of the cine 4D-CT, and the disadvantages of 1.8 times broadening of SSP and requires an additional breathing cycle of scanning to ensure an adequate sampling at the start and end locations. The cine 4D-CT has the advantages of maintaining the same SSP as slice collimation (e.g., 8 x 2.5 mm slice collimation generates 2.5 mm SSP in the cine 4D-CT as opposed to 4.5 mm in the helical 4D-CT) and a lower dose by 4% on the 8- and 16-slice systems, and 8% on the 4-slice system. The advantage of faster scanning in the helical 4D-CT will diminish if a repeat scan at the location of a breathing irregularity becomes necessary. The cine 4D-CT performs better than the helical 4D-CT in the repeat scan because it can scan faster and is more dose efficient.

  18. Gas turbine engines and transmissions for bus demonstration program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigro, D.N.

    1981-11-01

    This final report is to fulfill the contractural requirements of Contract DE-AC02-78CS54867 which required the delivery of 11 Allison GT 404-4 Industrial Gas Turbine Engines and five HT740CT and six V730CT Allison Automatic Transmissions for the Greyhound and Transit Coaches, respectively. In addition, software items such as cost reports, technical reports, installation drawings, acceptance test data and parts lists were required. Engine and transmission deliveries were completed with shipment of the last power package on 11 April 1980. Software items were submitted when required during the performance period of this contract.

  19. SU-E-T-317: The Development of a DIBH Technique for Left Sided Breast Patients Undergoing Radiation Therapy Utilizing Varians RPM System in a Community Hospital

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasson, B; Young, M; Workie, D

    2014-06-01

    Purpose: To develop and implement a Deep Inhalation Breath Hold program (DIBH) for treatment of patients with Left-sided breast cancer in a community hospital. Methods: All patients with left sided breast cancer underwent a screening free breathing CT. Evaluation of the conventional tangent treatment fields and the heart was conducted. If the heart would not be excluded using tangents, the patient then received DIBH breathe coaching. The patients returned for a 4D CT simulation. The patients breathing cycle was monitored using the Varian Real-Time position ManagementTM (RPM) system to assess duration of DIBH, amplitude, phase and recovery time to normalmore » breathing. Then a DIBH CT was obtained at the desired amplitude. Duplicate plans were developed for both free breathing and DIBH on the Eclipse planning system and comparison DVH's were created. The plan that provided the prescribed treatment coverage and the least doses to the OAR (heart, Lt. Lung) was determined. Those patients selected to receive treatment with DIBH were set up for treatment, and breathing was monitored using the RPM system. Practice trials were used to confirm that the amplitude, phase and recovery were consistent with findings from simulation. Results: 10 patients have been treated using the DIBH procedure in our clinic. The DIBH patients had an average increase of 80% lung volume on DIBH, decreased lung volume receiving 50% of the dose, and decreases in the V20 dose. Significant reduction in the maximum and mean dose to the heart, as well as the dose to 1CC of the volume for the DIBH plans. Conclusion: Using the RPM system already available in the clinic, staff training, and patient coaching a simple DIBH program was setup. The use of DIBH has shown promise in reducing doses to the critical organs while maintaining PTV coverage for left sided breast treatments.« less

  20. A Brief Peer Support Intervention for Veterans with Chronic Musculoskeletal Pain: A Pilot Study of Feasibility and Effectiveness

    PubMed Central

    Matthias, Marianne S.; McGuire, Alan B.; Kukla, Marina; Daggy, Joanne; Myers, Laura J.; Bair, Matthew J.

    2016-01-01

    Objective To pilot test a peer support intervention, involving peer delivery of pain self-management strategies, for veterans with chronic musculoskeletal pain. Design Pre-test/post-test with 4-month intervention period. Methods Ten peer coaches were each assigned 2 patients (n=20 patients). All had chronic musculoskeletal pain. Guided by a study manual, peer coach-patient pairs were instructed to talk bi-weekly for 4 months. Pain was the primary outcome and was assessed with the PEG, a 3-item version of the Brief Pain Inventory, and the PROMIS Pain Interference Questionnaire. Several secondary outcomes were also assessed. To assess change in outcomes, a linear mixed model with a random effect for peer coaches was applied. Results Nine peer coaches and 17 patients completed the study. All were male veterans. Patients’ pain improved at 4 months compared to baseline but did not reach statistical significance (PEG: p = .33, ICC [intra-class correlation] = .28, Cohen's d = −.25; PROMIS: p = .17, d = −.35). Of secondary outcomes, self-efficacy (p = .16, ICC = .56, d = .60) and pain centrality (p = .06, ICC = .32, d = −.62) showed greatest improvement, with moderate effect sizes. Conclusions This study suggests that peers can effectively deliver pain self-management strategies to other veterans with pain. Although this was a pilot study with a relatively short intervention period, patients improved on several outcomes. PMID:25312858

  1. Preoperative 4D CT Localization of Nonlocalizing Parathyroid Adenomas by Ultrasound and SPECT-CT.

    PubMed

    Hinson, Andrew M; Lee, David R; Hobbs, Bradley A; Fitzgerald, Ryan T; Bodenner, Donald L; Stack, Brendan C

    2015-11-01

    To evaluate 4-dimensional (4D) computed tomography (CT) for the localization of parathyroid adenomas previously considered nonlocalizing on ultrasound and single-photon emission CT with CT scanning (SPECT-CT). To measure radiation exposure associated with 4D-CT and compared it with SPECT-CT. Case series with chart review. University tertiary hospital. Nineteen adults with primary hyperparathyroidism who underwent preoperative 4D CT from November 2013 through July 2014 after nonlocalizing preoperative ultrasound and technetium-99m SPECT-CT scans. Sensitivity, specificity, predictive values, and accuracy of 4D CT were evaluated. Nineteen patients (16 women and 3 men) were included with a mean age of 66 years (range, 39-80 years). Mean preoperative parathyroid hormone level was 108.5 pg/mL (range, 59.3-220.9 pg/mL), and mean weight of the excised gland was 350 mg (range, 83-797 mg). 4D CT sensitivity and specificity for localization to the patient's correct side of the neck were 84.2% and 81.8%, respectively; accuracy was 82.9%. The sensitivity for localizing adenomas to the correct quadrant was 76.5% and 91.5%, respectively; accuracy was 88.2%. 4D CT radiation exposure was significantly less than the radiation associated with SPECT-CT (13.8 vs 18.4 mSv, P = 0.04). 4D CT localizes parathyroid adenomas with relatively high sensitivity and specificity and allows for the localization of some adenomas not observed on other sestamibi-based scans. 4D CT was also associated with less radiation exposure when compared with SPECT-CT based on our study protocol. 4D CT may be considered as first- or second-line imaging for localizing parathyroid adenomas in the setting of primary hyperparathyroidism. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  2. The Appropriation of the Coaching with CARE Model with Preservice Teachers: The Role of Community

    ERIC Educational Resources Information Center

    Maloch, Beth; Wetzel, Melissa Mosley; Hoffman, James V.; Taylor, Laura A.; Pruitt, Alina; Vlach, Saba Khan; Greeter, Erin

    2015-01-01

    This study is part of a longitudinal, multiphase study on development of literacy mentoring practices particularly with regard to the cooperating teacher. This paper reports on the findings from the first year of the study during which cooperating teachers (CT) participated in a master's program focused on coaching and mentoring while mentoring…

  3. Health Coaching to Optimize Well-Being among Returning Veterans with Suicide Risk

    DTIC Science & Technology

    2017-10-01

    AWARD NUMBER: W81XWH-16-1-0630 TITLE: Health Coaching to Optimize Well-Being among Returning Veterans with Suicide Risk PRINCIPAL INVESTIGATOR...Lauren M. Denneson, PhD CONTRACTING ORGANIZATION: Oregon Health & Science University Portland, OR 97239 REPORT DATE: October 2017 TYPE OF...COVERED (From - To) 15 Sept 2016 - 14 Sept 2017 4. TITLE AND SUBTITLE Health Coaching to Optimize Well-Being among Returning Veterans with Suicide Risk

  4. Simulation of spatiotemporal CT data sets using a 4D MRI-based lung motion model.

    PubMed

    Marx, Mirko; Ehrhardt, Jan; Werner, René; Schlemmer, Heinz-Peter; Handels, Heinz

    2014-05-01

    Four-dimensional CT imaging is widely used to account for motion-related effects during radiotherapy planning of lung cancer patients. However, 4D CT often contains motion artifacts, cannot be used to measure motion variability, and leads to higher dose exposure. In this article, we propose using 4D MRI to acquire motion information for the radiotherapy planning process. From the 4D MRI images, we derive a time-continuous model of the average patient-specific respiratory motion, which is then applied to simulate 4D CT data based on a static 3D CT. The idea of the motion model is to represent the average lung motion over a respiratory cycle by cyclic B-spline curves. The model generation consists of motion field estimation in the 4D MRI data by nonlinear registration, assigning respiratory phases to the motion fields, and applying a B-spline approximation on a voxel-by-voxel basis to describe the average voxel motion over a breathing cycle. To simulate a patient-specific 4D CT based on a static CT of the patient, a multi-modal registration strategy is introduced to transfer the motion model from MRI to the static CT coordinates. Differences between model-based estimated and measured motion vectors are on average 1.39 mm for amplitude-based binning of the 4D MRI data of three patients. In addition, the MRI-to-CT registration strategy is shown to be suitable for the model transformation. The application of our 4D MRI-based motion model for simulating 4D CT images provides advantages over standard 4D CT (less motion artifacts, radiation-free). This makes it interesting for radiotherapy planning.

  5. 4D CT amplitude binning for the generation of a time-averaged 3D mid-position CT scan

    NASA Astrophysics Data System (ADS)

    Kruis, Matthijs F.; van de Kamer, Jeroen B.; Belderbos, José S. A.; Sonke, Jan-Jakob; van Herk, Marcel

    2014-09-01

    The purpose of this study was to develop a method to use amplitude binned 4D-CT (A-4D-CT) data for the construction of mid-position CT data and to compare the results with data created from phase-binned 4D-CT (P-4D-CT) data. For the latter purpose we have developed two measures which describe the regularity of the 4D data and we have tried to correlate these measures with the regularity of the external respiration signal. 4D-CT data was acquired for 27 patients on a combined PET-CT scanner. The 4D data were reconstructed twice, using phase and amplitude binning. The 4D frames of each dataset were registered using a quadrature-based optical flow method. After registration the deformation vector field was repositioned to the mid-position. Since amplitude-binned 4D data does not provide temporal information, we corrected the mid-position for the occupancy of the bins. We quantified the differences between the two mid-position datasets in terms of tumour offset and amplitude differences. Furthermore, we measured the standard deviation of the image intensity over the respiration after registration (σregistration) and the regularity of the deformation vector field (\\overline{\\Delta |J|} ) to quantify the quality of the 4D-CT data. These measures were correlated to the regularity of the external respiration signal (σsignal). The two irregularity measures, \\overline{\\Delta |J|} and σregistration, were dependent on each other (p < 0.0001, R2 = 0.80 for P-4D-CT, R2 = 0.74 for A-4D-CT). For all datasets amplitude binning resulted in lower \\overline{\\Delta |J|} and σregistration and large decreases led to visible quality improvements in the mid-position data. The quantity of artefact decrease was correlated to the irregularity of the external respiratory signal. The average tumour offset between the phase and amplitude binned mid-position without occupancy correction was 0.42 mm in the caudal direction (10.6% of the amplitude). After correction this was reduced to 0.16 mm in caudal direction (4.1% of the amplitude). Similar relative offsets were found at the diaphragm. We have devised a method to use amplitude binned 4D-CT to construct motion model and generate a mid-position planning CT for radiotherapy treatment purposes. We have decimated the systematic offset of this mid-position model with a motion model derived from P-4D-CT. We found that the A-4D-CT led to a decrease of local artefacts and that this decrease was correlated to the irregularity of the external respiration signal.

  6. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, Y; Bowsher, J; Yan, S

    2014-06-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medicalmore » Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.« less

  7. Validation of a 4D-PET Maximum Intensity Projection for Delineation of an Internal Target Volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Callahan, Jason, E-mail: jason.callahan@petermac.org; Kron, Tomas; Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne

    2013-07-15

    Purpose: The delineation of internal target volumes (ITVs) in radiation therapy of lung tumors is currently performed by use of either free-breathing (FB) {sup 18}F-fluorodeoxyglucose-positron emission tomography-computed tomography (FDG-PET/CT) or 4-dimensional (4D)-CT maximum intensity projection (MIP). In this report we validate the use of 4D-PET-MIP for the delineation of target volumes in both a phantom and in patients. Methods and Materials: A phantom with 3 hollow spheres was prepared surrounded by air then water. The spheres and water background were filled with a mixture of {sup 18}F and radiographic contrast medium. A 4D-PET/CT scan was performed of the phantom whilemore » moving in 4 different breathing patterns using a programmable motion device. Nine patients with an FDG-avid lung tumor who underwent FB and 4D-PET/CT and >5 mm of tumor motion were included for analysis. The 3 spheres and patient lesions were contoured by 2 contouring methods (40% of maximum and PET edge) on the FB-PET, FB-CT, 4D-PET, 4D-PET-MIP, and 4D-CT-MIP. The concordance between the different contoured volumes was calculated using a Dice coefficient (DC). The difference in lung tumor volumes between FB-PET and 4D-PET volumes was also measured. Results: The average DC in the phantom using 40% and PET edge, respectively, was lowest for FB-PET/CT (DCAir = 0.72/0.67, DCBackground 0.63/0.62) and highest for 4D-PET/CT-MIP (DCAir = 0.84/0.83, DCBackground = 0.78/0.73). The average DC in the 9 patients using 40% and PET edge, respectively, was also lowest for FB-PET/CT (DC = 0.45/0.44) and highest for 4D-PET/CT-MIP (DC = 0.72/0.73). In the 9 lesions, the target volumes of the FB-PET using 40% and PET edge, respectively, were on average 40% and 45% smaller than the 4D-PET-MIP. Conclusion: A 4D-PET-MIP produces volumes with the highest concordance with 4D-CT-MIP across multiple breathing patterns and lesion sizes in both a phantom and among patients. Freebreathing PET/CT consistently underestimates ITV when compared with 4D PET/CT for a lesion affected by respiration.« less

  8. 4D-Listmode-PET-CT and 4D-CT for optimizing PTV margins in gastric lymphoma : Determination of intra- and interfractional gastric motion.

    PubMed

    Reinartz, Gabriele; Haverkamp, Uwe; Wullenkord, Ramona; Lehrich, Philipp; Kriz, Jan; Büther, Florian; Schäfers, Klaus; Schäfers, Michael; Eich, Hans Theodor

    2016-05-01

    New imaging protocols for radiotherapy in localized gastric lymphoma were evaluated to optimize planning target volume (PTV) margin and determine intra-/interfractional variation of the stomach. Imaging of 6 patients was explored prospectively. Intensity-modulated radiotherapy (IMRT) planning was based on 4D/3D imaging of computed tomography (CT) and positron-emission tomography (PET)-CT. Static and motion gross tumor volume (sGTV and mGTV, respectively) were distinguished by defining GTV (empty stomach), clinical target volume (CTV = GTV + 5 mm margin), PTV (GTV + 10/15/20/25 mm margins)  plus paraaortic lymph nodes and proximal duodenum. Overlap of 4D-Listmode-PET-based mCTV with 3D-CT-based PTV (increasing margins) and V95/D95 of mCTV were evaluated. Gastric shifts were determined using online cone-beam CT. Dose contribution to organs at risk was assessed. The 4D data demonstrate considerable intra-/interfractional variation of the stomach, especially along the vertical axis. Conventional 3D-CT planning utilizing advancing PTV margins of 10/15/20/25 mm resulted in rising dose coverage of mCTV (4D-Listmode-PET-Summation-CT) and rising D95 and V95 of mCTV. A PTV margin of 15 mm was adequate in 3 of 6 patients, a PTV margin of 20 mm was adequate in 4 of 6 patients, and a PTV margin of 25 mm was adequate in 5 of 6 patients. IMRT planning based on 4D-PET-CT/4D-CT together with online cone-beam CT is advisable to individualize the PTV margin and optimize target coverage in gastric lymphoma.

  9. Target volume and artifact evaluation of a new data-driven 4D CT.

    PubMed

    Martin, Rachael; Pan, Tinsu

    Four-dimensional computed tomography (4D CT) is often used to define the internal gross target volume (IGTV) for radiation therapy of lung cancer. Traditionally, this technique requires the use of an external motion surrogate; however, a new image, data-driven 4D CT, has become available. This study aims to describe this data-driven 4D CT and compare target contours created with it to those created using standard 4D CT. Cine CT data of 35 patients undergoing stereotactic body radiation therapy were collected and sorted into phases using standard and data-driven 4D CT. IGTV contours were drawn using a semiautomated method on maximum intensity projection images of both 4D CT methods. Errors resulting from reproducibility of the method were characterized. A comparison of phase image artifacts was made using a normalized cross-correlation method that assigned a score from +1 (data-driven "better") to -1 (standard "better"). The volume difference between the data-driven and standard IGTVs was not significant (data driven was 2.1 ± 1.0% smaller, P = .08). The Dice similarity coefficient showed good similarity between the contours (0.949 ± 0.006). The mean surface separation was 0.4 ± 0.1 mm and the Hausdorff distance was 3.1 ± 0.4 mm. An average artifact score of +0.37 indicated that the data-driven method had significantly fewer and/or less severe artifacts than the standard method (P = 1.5 × 10 -5 for difference from 0). On average, the difference between IGTVs derived from data-driven and standard 4D CT was not clinically relevant or statistically significant, suggesting data-driven 4D CT can be used in place of standard 4D CT without adjustments to IGTVs. The relatively large differences in some patients were usually attributed to limitations in automatic contouring or differences in artifacts. Artifact reduction and setup simplicity suggest a clinical advantage to data-driven 4D CT. Published by Elsevier Inc.

  10. TH-E-17A-04: Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yue, Y; Fan, Z; Yang, W

    Purpose: 4D-CT is often limited by motion artifacts, low temporal resolution, and poor phase-based target definition. We recently developed a novel k-space self-gated 4D-MRI technique with high spatial and temporal resolution. The goal here is to geometrically validate 4D-MRI using a MRI-CT compatible respiratory motion phantom and comparison to 4D-CT. Methods: 4D-MRI was acquired using 3T spoiled gradient echo-based 3D projection sequences. Respiratory phases were resolved using self-gated k-space lines as the motion surrogate. Images were reconstructed into 10 temporal bins with 1.56×1.56×1.56mm3. A MRI-CT compatible phantom was designed with a 23mm diameter ball target filled with highconcentration gadolinium(Gd) gelmore » embedded in a 35×40×63mm3 plastic box stabilized with low-concentration Gd gel. The whole phantom was driven by an air pump. Human respiratory motion was mimicked using the controller from a commercial dynamic phantom (RSD). Four breathing settings (rates/depths: 10s/20mm, 6s/15mm, 4s/10mm, 3s/7mm) were scanned with 4D-MRI and 4D-CT (slice thickness 1.25mm). Motion ground-truth was obtained from input signals and real-time video recordings. Reconstructed images were imported into Eclipse(Varian) for target contouring. Volumes and target positions were compared with ground-truth. Initial human study was investigated on a liver patient. Results: 4D-MRI and 4D-CT scans for the different breathing cycles were reconstructed with 10 phases. Target volume in each phase was measured for both 4D-CT and 4D-MRI. Volume percentage difference for the 6.37ml target ranged from 6.67±5.33 to 11.63±5.57 for 4D-CT and from 1.47±0.52 to 2.12±1.60 for 4D-MRI. The Mann-Whitney U-test shows the 4D-MRI is significantly superior to 4D-CT (p=0.021) for phase-based target definition. Centroid motion error ranges were 1.35–1.25mm (4D-CT), and 0.31–0.12mm (4D-MRI). Conclusion: The k-space self-gated 4D-MRI we recently developed can accurately determine phase-based target volume while avoiding typical motion artifacts found in 4D-CT, and is being further studied for use in GI targeting and motion management. This work supported in part by grant 1R03CA173273-01.« less

  11. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion.

    PubMed

    Yang, Y X; Teo, S-K; Van Reeth, E; Tan, C H; Tham, I W K; Poh, C L

    2015-08-01

    Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors' proposed approach. A novel hybrid approach based on deformable image registration (DIR) and finite element method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error <2 mm) were achieved using the authors' proposed approach. Their hybrid approach achieved a 40% error reduction (based on landmarks assessment) over using only DIR techniques. The synthetic 4D-CT dataset generated has high spatial resolution, has excellent lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.

  12. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: a digital phantom study.

    PubMed

    Bernatowicz, K; Keall, P; Mishra, P; Knopf, A; Lomax, A; Kipritidis, J

    2015-01-01

    Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) "conventional" 4D CT that uses a constant imaging and couch-shift frequency, (ii) "beam paused" 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) "respiratory-gated" 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm(3) spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10(-19)). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%-1.4%), false positives (4.0%-2.6%), and false negatives (2.7%-1.3%). These percentage reductions correspond to gating reducing image artifacts by 24-90 cm(3) of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm(3) of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.

  13. Assessment of Intrafraction Breathing Motion on Left Anterior Descending Artery Dose During Left-Sided Breast Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El-Sherif, Omar, E-mail: Omar.ElSherif@lhsc.on.ca; Department of Physics, London Regional Cancer Program, London, Ontario; Yu, Edward

    Purpose: To use 4-dimensional computed tomography (4D-CT) imaging to predict the level of uncertainty in cardiac dose estimates of the left anterior descending artery that arises due to breathing motion during radiation therapy for left-sided breast cancer. Methods and Materials: The fast helical CT (FH-CT) and 4D-CT of 30 left-sided breast cancer patients were retrospectively analyzed. Treatment plans were created on the FH-CT. The original treatment plan was then superimposed onto all 10 phases of the 4D-CT to quantify the dosimetric impact of respiratory motion through 4D dose accumulation (4D-dose). Dose-volume histograms for the heart, left ventricle (LV), and left anteriormore » descending (LAD) artery obtained from the FH-CT were compared with those obtained from the 4D-dose. Results: The 95% confidence interval of 4D-dose and FH-CT differences in mean dose estimates for the heart, LV, and LAD were ±0.5 Gy, ±1.0 Gy, and ±8.7 Gy, respectively. Conclusion: Fast helical CT is a good approximation for doses to the heart and LV; however, dose estimates for the LAD are susceptible to uncertainties that arise due to intrafraction breathing motion that cannot be ascertained without the additional information obtained from 4D-CT and dose accumulation. For future clinical studies, we suggest the use of 4D-CT–derived dose-volume histograms for estimating the dose to the LAD.« less

  14. New prospective 4D-CT for mitigating the effects of irregular respiratory motion

    NASA Astrophysics Data System (ADS)

    Pan, Tinsu; Martin, Rachael M.; Luo, Dershan

    2017-08-01

    Artifact caused by irregular respiration is a major source of error in 4D-CT imaging. We propose a new prospective 4D-CT to mitigate this source of error without new hardware, software or off-line data-processing on the GE CT scanner. We utilize the cine CT scan in the design of the new prospective 4D-CT. The cine CT scan at each position can be stopped by the operator when an irregular respiration occurs, and resumed when the respiration becomes regular. This process can be repeated at one or multiple scan positions. After the scan, a retrospective reconstruction is initiated on the CT console to reconstruct only the images corresponding to the regular respiratory cycles. The end result is a 4D-CT free of irregular respiration. To prove feasibility, we conducted a phantom and six patient studies. The artifacts associated with the irregular respiratory cycles could be removed from both the phantom and patient studies. A new prospective 4D-CT scanning and processing technique to mitigate the impact of irregular respiration in 4D-CT has been demonstrated. This technique can save radiation dose because the repeat scans are only at the scan positions where an irregular respiration occurs. Current practice is to repeat the scans at all positions. There is no cost to apply this technique because it is applicable on the GE CT scanner without new hardware, software or off-line data-processing.

  15. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Y. X.; Van Reeth, E.; Poh, C. L., E-mail: clpoh@ntu.edu.sg

    2015-08-15

    Purpose: Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors’ proposed approach. Methods: A novel hybrid approach based on deformable image registration (DIR) and finite elementmore » method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. Results: The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error <2 mm) were achieved using the authors’ proposed approach. Their hybrid approach achieved a 40% error reduction (based on landmarks assessment) over using only DIR techniques. Conclusions: The synthetic 4D-CT dataset generated has high spatial resolution, has excellent lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.« less

  16. Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yue, Yong, E-mail: yong.yue@cshs.org; Yang, Wensha; McKenzie, Elizabeth

    Purpose: MRI is increasingly being used for radiotherapy planning, simulation, and in-treatment-room motion monitoring. To provide more detailed temporal and spatial MR data for these tasks, we have recently developed a novel self-gated (SG) MRI technique with advantage of k-space phase sorting, high isotropic spatial resolution, and high temporal resolution. The current work describes the validation of this 4D-MRI technique using a MRI- and CT-compatible respiratory motion phantom and comparison to 4D-CT. Methods: The 4D-MRI sequence is based on a spoiled gradient echo-based 3D projection reconstruction sequence with self-gating for 4D-MRI at 3 T. Respiratory phase is resolved by usingmore » SG k-space lines as the motion surrogate. 4D-MRI images are reconstructed into ten temporal bins with spatial resolution 1.56 × 1.56 × 1.56 mm{sup 3}. A MRI-CT compatible phantom was designed to validate the performance of the 4D-MRI sequence and 4D-CT imaging. A spherical target (diameter 23 mm, volume 6.37 ml) filled with high-concentration gadolinium (Gd) gel is embedded into a plastic box (35 × 40 × 63 mm{sup 3}) and stabilized with low-concentration Gd gel. The phantom, driven by an air pump, is able to produce human-type breathing patterns between 4 and 30 respiratory cycles/min. 4D-CT of the phantom has been acquired in cine mode, and reconstructed into ten phases with slice thickness 1.25 mm. The 4D images sets were imported into a treatment planning software for target contouring. The geometrical accuracy of the 4D MRI and CT images has been quantified using target volume, flattening, and eccentricity. The target motion was measured by tracking the centroids of the spheres in each individual phase. Motion ground-truth was obtained from input signals and real-time video recordings. Results: The dynamic phantom has been operated in four respiratory rate (RR) settings, 6, 10, 15, and 20/min, and was scanned with 4D-MRI and 4D-CT. 4D-CT images have target-stretching, partial-missing, and other motion artifacts in various phases, whereas the 4D-MRI images are visually free of those artifacts. Volume percentage difference for the 6.37 ml target ranged from 5.3% ± 4.3% to 10.3% ± 5.9% for 4D-CT, and 1.47 ± 0.52 to 2.12 ± 1.60 for 4D-MRI. With an increase of respiratory rate, the target volumetric and geometric deviations increase for 4D-CT images while remaining stable for the 4D-MRI images. Target motion amplitude errors at different RRs were measured with a range of 0.66–1.25 mm for 4D-CT and 0.2–0.42 mm for 4D-MRI. The results of Mann–Whitney tests indicated that 4D-MRI significantly outperforms 4D-CT in phase-based target volumetric (p = 0.027) and geometric (p < 0.001) measures. Both modalities achieve equivalent accuracy in measuring motion amplitude (p = 0.828). Conclusions: The k-space self-gated 4D-MRI technique provides a robust method for accurately imaging phase-based target motion and geometry. Compared to 4D-CT, the current 4D-MRI technique demonstrates superior spatiotemporal resolution, and robust resistance to motion artifacts caused by fast target motion and irregular breathing patterns. The technique can be used extensively in abdominal targeting, motion gating, and toward implementing MRI-based adaptive radiotherapy.« less

  17. Clinical evaluation of respiration-induced attenuation uncertainties in pulmonary 3D PET/CT.

    PubMed

    Kruis, Matthijs F; van de Kamer, Jeroen B; Vogel, Wouter V; Belderbos, José Sa; Sonke, Jan-Jakob; van Herk, Marcel

    2015-12-01

    In contemporary positron emission tomography (PET)/computed tomography (CT) scanners, PET attenuation correction is performed by means of a CT-based attenuation map. Respiratory motion can however induce offsets between the PET and CT data. Studies have demonstrated that these offsets can cause errors in quantitative PET measures. The purpose of this study is to quantify the effects of respiration-induced CT differences on the attenuation correction of pulmonary 18-fluordeoxyglucose (FDG) 3D PET/CT in a patient population and to investigate contributing factors. For 32 lung cancer patients, 3D-CT, 4D-PET and 4D-CT data were acquired. The 4D FDG PET data were attenuation corrected (AC) using a free-breathing 3D-CT (3D-AC), the end-inspiration CT (EI-AC), the end-expiration CT (EE-AC) or phase-by-phase (P-AC). After reconstruction and AC, the 4D-PET data were averaged. In the 4Davg data, we measured maximum tumour standardised uptake value (SUV)max in the tumour, SUVmean in a lung volume of interest (VOI) and average SUV (SUVmean) in a muscle VOI. On the 4D-CT, we measured the lung volume differences and CT number changes between inhale and exhale in the lung VOI. Compared to P-AC, we found -2.3% (range -9.7% to 1.2%) lower tumour SUVmax in EI-AC and 2.0% (range -0.9% to 9.5%) higher SUVmax in EE-AC. No differences in the muscle SUV were found. The use of 3D-AC led to respiration-induced SUVmax differences up to 20% compared to the use of P-AC. SUVmean differences in the lung VOI between EI-AC and EE-AC correlated to average CT differences in this region (ρ = 0.83). SUVmax differences in the tumour correlated to the volume changes of the lungs (ρ = -0.55) and the motion amplitude of the tumour (ρ = 0.53), both as measured on the 4D-CT. Respiration-induced CT variations in clinical data can in extreme cases lead to SUV effects larger than 10% on PET attenuation correction. These differences were case specific and correlated to differences in CT number in the lungs.

  18. 4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines.

    PubMed

    Min, Yugang; Neylon, John; Shah, Amish; Meeks, Sanford; Lee, Percy; Kupelian, Patrick; Santhanam, Anand P

    2014-09-01

    The accuracy of 4D-CT registration is limited by inconsistent Hounsfield unit (HU) values in the 4D-CT data from one respiratory phase to another and lower image contrast for lung substructures. This paper presents an optical flow and thin-plate spline (TPS)-based 4D-CT registration method to account for these limitations. The use of unified HU values on multiple anatomy levels (e.g., the lung contour, blood vessels, and parenchyma) accounts for registration errors by inconsistent landmark HU value. While 3D multi-resolution optical flow analysis registers each anatomical level, TPS is employed for propagating the results from one anatomical level to another ultimately leading to the 4D-CT registration. 4D-CT registration was validated using target registration error (TRE), inverse consistency error (ICE) metrics, and a statistical image comparison using Gamma criteria of 1 % intensity difference in 2 mm(3) window range. Validation results showed that the proposed method was able to register CT lung datasets with TRE and ICE values <3 mm. In addition, the average number of voxel that failed the Gamma criteria was <3 %, which supports the clinical applicability of the propose registration mechanism. The proposed 4D-CT registration computes the volumetric lung deformations within clinically viable accuracy.

  19. Coaching patients On Achieving Cardiovascular Health (COACH): a multicenter randomized trial in patients with coronary heart disease.

    PubMed

    Vale, Margarite J; Jelinek, Michael V; Best, James D; Dart, Anthony M; Grigg, Leeanne E; Hare, David L; Ho, Betty P; Newman, Robert W; McNeil, John J

    Disease management programs in which drugs are prescribed by dietitians or nurses have been shown to improve the coronary risk factor profile in patients with coronary heart disease. However, those disease management programs in which drugs are not prescribed by allied health professionals have not improved coronary risk factor status. The objective of the Coaching patients On Achieving Cardiovascular Health (COACH) study was to determine whether dietitians or nurses who did not prescribe medications could coach patients with coronary heart disease to work with their physicians to achieve the target levels for their total cholesterol (TC) and other risk factors. Multicenter randomized controlled trial in which 792 patients from 6 university teaching hospitals underwent a stratified randomization by cardiac diagnosis within each hospital: 398 were assigned to usual care plus The COACH Program and 394 to usual care alone. Patients in The COACH Program group received regular personal coaching via telephone and mailings to achieve the target levels for their particular coronary risk factors. There was one coach per hospital. The primary outcome was the change in TC (DeltaTC) from baseline (in hospital) to 6 months after randomization. Secondary outcomes included measurement of a wide range of physical, nutritional, and psychological factors. The analysis was performed by intention to treat. The COACH Program achieved a significantly greater DeltaTC than usual care alone: the mean DeltaTC was 21 mg/dL (0.54 mmol/L) (95% confidence interval [CI], 16-25 mg/dL [0.42-0.65 mmol/L]) in The COACH Program vs 7 mg/dL (0.18 mmol/L) (95% CI, 3-11 mg/dL [0.07-0.29 mmol/L]) in the usual care group (P<.0001). Thus, the reduction in TC from baseline to 6 months after randomization was 14 mg/dL (0.36 mmol/L) (95% CI, 8-20 mg/dL [0.20-0.52 mmol/L]) greater in The COACH Program group than in the usual care group. Coaching produced substantial improvements in most of the other coronary risk factors and in patient quality of life. Coaching, delivered as The COACH Program, is a highly effective strategy in reducing TC and many other coronary risk factors in patients with coronary heart disease. Coaching has potential effectiveness in the whole area of chronic disease management.

  20. Coaches' perspectives on implementing an evidence-informed injury prevention programme in junior community netball.

    PubMed

    Saunders, N; Otago, L; Romiti, M; Donaldson, A; White, P; Finch, Cf

    2010-12-01

    For effective sports injury prevention, information is needed about the implementation context for interventions. This study describes coaches' feedback on the implementation of an evidence-informed injury prevention programme in community junior netball using coaches' perceptions and the RE-AIM framework. A lower-limb injury prevention programme (Down to Earth; D2E), for teaching safe-landing techniques, was delivered to 31 coaches from 31 junior community netball teams in a 1-h workshop. Coaches then delivered a 6-week programme at team training sessions starting in the week before the competition season commenced. 65% of coaches completed a feedback survey 17 weeks after they had delivered the programme. Most (88%) coaches believed that D2E improved their players' ability to perform correct landing techniques in games and that players had retained these improvements over the season. The majority (83%) indicated that an improvement in player athletic attributes was the greatest advantage of D2E, followed by a reduction in injury risk. Identified barriers to implementing D2E were running out of time and very young players finding the drills too difficult. Coaches reported that they needed more ideas for training drills that could be incorporated into their programmes and believed that their own coaching training did not adequately prepare them to implement an injury prevention programme. Although coaches believed that D2E was effective in developing correct landing techniques, some modifications are needed to make it more suitable for younger players and coach education by accreditation courses could be improved to support the implementation of injury prevention programmes.

  1. SU-E-J-120: Comparing 4D CT Computed Ventilation to Lung Function Measured with Hyperpolarized Xenon-129 MRI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neal, B; Chen, Q

    2015-06-15

    Purpose: To correlate ventilation parameters computed from 4D CT to ventilation, profusion, and gas exchange measured with hyperpolarized Xenon-129 MRI for a set of lung cancer patients. Methods: Hyperpolarized Xe-129 MRI lung scans were acquired for lung cancer patients, before and after radiation therapy, measuring ventilation, perfusion, and gas exchange. In the standard clinical workflow, these patients also received 4D CT scans before treatment. Ventilation was computed from 4D CT using deformable image registration (DIR). All phases of the 4D CT scan were registered using a B-spline deformable registration. Ventilation at the voxel level was then computed for each phasemore » based on a Jacobian volume expansion metric, yielding phase sorted ventilation images. Ventilation based upon 4D CT and Xe-129 MRI were co-registered, allowing qualitative visual comparison and qualitative comparison via the Pearson correlation coefficient. Results: Analysis shows a weak correlation between hyperpolarized Xe-129 MRI and 4D CT DIR ventilation, with a Pearson correlation coefficient of 0.17 to 0.22. Further work will refine the DIR parameters to optimize the correlation. The weak correlation could be due to the limitations of 4D CT, registration algorithms, or the Xe-129 MRI imaging. Continued development will refine parameters to optimize correlation. Conclusion: Current analysis yields a minimal correlation between 4D CT DIR and Xe-129 MRI ventilation. Funding provided by the 2014 George Amorino Pilot Grant in Radiation Oncology at the University of Virginia.« less

  2. SU-F-P-32: A Phantom Study of Accuracy of Four-Dimensional Cone-Beam CT (4D-CBCT) Vs. Three-Dimensional Cone Beam CT (3D-CBCT) in Image Guided Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, R; Morris, B; Duggar, N

    2016-06-15

    Purpose: SymmetryTM 4D IGRT system of Elekta has been installed at our institution, which offers the 4D CBCT registration option. This study is to evaluate the accuracy of 4D CBCT system by using the CIRS 4D motion phantom and to perform a feasibility study on the implementation of 4D-CBCT as image guidance for SBRT treatment. Methods: The 3D and 4D CT image data sets are acquired using the CIRS motion phantom on a Philips large bore CT simulator. The motion was set as 0.5 cm superior and inferior directions with 6 seconds recycle time. The 4D CT data were sortedmore » as 10 phases. One identifiable part of the 4D CT QA insert from CIRS phantom was used as the target. The ITV MIP was drawn based on maximum intensity projection (MIP) and transferred as a planning structure into 4D CBCT system. Then the 3D CBCT and 4D CBCT images were taken and registered with the free breath (3D), MIP (4D) and average intensity projection (AIP)(4D) reference data sets. The couch shifts (X, Y, Z) are recorded and compared. Results: Table 1 listed the twelve couch shifts based on the registration of MIP, AIP and free breath CT data sets with 3D CBCT and 4D CBCT for both whole body and local registration. X, Y and Z represent couch shifts in the direction of the right-left, superior-inferior and anterior-posterior. The biggest differences of 0.73 cm and 0.57 cm are noted in the free breath CT data with 4D CBCT and 3D CBCT data registration. Fig. 1 and Fig. 2 are the shift analysis in diagram. Fig. 3 shows the registration. Conclusion: Significant differences exist in the shifts corresponding with the direction of target motion. Further investigations are ongoing.« less

  3. Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration.

    PubMed

    Wolthaus, J W H; Sonke, J J; van Herk, M; Damen, E M F

    2008-09-01

    lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods < 0.5 mm for all directions) for the tumor region. From visual assessment, the registration was good for the clearly visible features (e.g., tumor and diaphragm). The shape of the tumor, with respect to that of the BH CT scan, was better represented by the MidP reconstructions than any of the 4D CT frames (including MidV; reduction of "shape differences" was 66%). The MidP scans contained about one-third the noise of individual 4D CT scan frames. We implemented an accurate method to estimate the motion of structures in a 4D CT scan. Subsequently, a novel method to create a midposition CT scan (time-weighted average of the anatomy) for treatment planning with reduced noise and artifacts was introduced. Tumor shape and position in the MidP CT scan represents that of the BH CT scan better than MidV CT scan and, therefore, was found to be appropriate for treatment planning.

  4. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernatowicz, K., E-mail: kingab@student.ethz.ch; Knopf, A.; Lomax, A.

    Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CTmore » can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10{sup −19}). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%–1.4%), false positives (4.0%–2.6%), and false negatives (2.7%–1.3%). These percentage reductions correspond to gating reducing image artifacts by 24–90 cm{sup 3} of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. Conclusions: For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm{sup 3} of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.« less

  5. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun

    2008-12-15

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACTmore » from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma ({gamma}) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass {gamma} criteria. The average maximum and mean {gamma} indices were very low (well below 1), indicating good agreement between dose distributions. Increasing the cine duration generally increased the dose agreement. In the follow-up study, 49 of 50 patients had 100% of points within the PTV pass the {gamma} criteria. The average maximum and mean {gamma} indices were again well below 1, indicating good agreement. Dose calculation on RACT from cine CT is negligibly different from dose calculation on RACT from 4D-CT. Differences can be decreased further by increasing the cine duration of the cine CT scan.« less

  6. Cine Computed Tomography Without Respiratory Surrogate in Planning Stereotactic Radiotherapy for Non-Small-Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riegel, Adam C. B.A.; Chang, Joe Y.; Vedam, Sastry S.

    2009-02-01

    Purpose: To determine whether cine computed tomography (CT) can serve as an alternative to four-dimensional (4D)-CT by providing tumor motion information and producing equivalent target volumes when used to contour in radiotherapy planning without a respiratory surrogate. Methods and Materials: Cine CT images from a commercial CT scanner were used to form maximum intensity projection and respiratory-averaged CT image sets. These image sets then were used together to define the targets for radiotherapy. Phantoms oscillating under irregular motion were used to assess the differences between contouring using cine CT and 4D-CT. We also retrospectively reviewed the image sets for 26more » patients (27 lesions) at our institution who had undergone stereotactic radiotherapy for Stage I non-small-cell lung cancer. The patients were included if the tumor motion was >1 cm. The lesions were first contoured using maximum intensity projection and respiratory-averaged CT image sets processed from cine CT and then with 4D-CT maximum intensity projection and 10-phase image sets. The mean ratios of the volume magnitude were compared with intraobserver variation, the mean centroid shifts were calculated, and the volume overlap was assessed with the normalized Dice similarity coefficient index. Results: The phantom studies demonstrated that cine CT captured a greater extent of irregular tumor motion than did 4D-CT, producing a larger tumor volume. The patient studies demonstrated that the gross tumor defined using cine CT imaging was similar to, or slightly larger than, that defined using 4D-CT. Conclusion: The results of our study have shown that cine CT is a promising alternative to 4D-CT for stereotactic radiotherapy planning.« less

  7. TH-E-BRF-02: 4D-CT Ventilation Image-Based IMRT Plans Are Dosimetrically Comparable to SPECT Ventilation Image-Based Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kida, S; University of Tokyo Hospital, Bunkyo, Tokyo; Bal, M

    Purpose: An emerging lung ventilation imaging method based on 4D-CT can be used in radiotherapy to selectively avoid irradiating highly-functional lung regions, which may reduce pulmonary toxicity. Efforts to validate 4DCT ventilation imaging have been focused on comparison with other imaging modalities including SPECT and xenon CT. The purpose of this study was to compare 4D-CT ventilation image-based functional IMRT plans with SPECT ventilation image-based plans as reference. Methods: 4D-CT and SPECT ventilation scans were acquired for five thoracic cancer patients in an IRB-approved prospective clinical trial. The ventilation images were created by quantitative analysis of regional volume changes (amore » surrogate for ventilation) using deformable image registration of the 4D-CT images. A pair of 4D-CT ventilation and SPECT ventilation image-based IMRT plans was created for each patient. Regional ventilation information was incorporated into lung dose-volume objectives for IMRT optimization by assigning different weights on a voxel-by-voxel basis. The objectives and constraints of the other structures in the plan were kept identical. The differences in the dose-volume metrics have been evaluated and tested by a paired t-test. SPECT ventilation was used to calculate the lung functional dose-volume metrics (i.e., mean dose, V20 and effective dose) for both 4D-CT ventilation image-based and SPECT ventilation image-based plans. Results: Overall there were no statistically significant differences in any dose-volume metrics between the 4D-CT and SPECT ventilation imagebased plans. For example, the average functional mean lung dose of the 4D-CT plans was 26.1±9.15 (Gy), which was comparable to 25.2±8.60 (Gy) of the SPECT plans (p = 0.89). For other critical organs and PTV, nonsignificant differences were found as well. Conclusion: This study has demonstrated that 4D-CT ventilation image-based functional IMRT plans are dosimetrically comparable to SPECT ventilation image-based plans, providing evidence to use 4D-CT ventilation imaging for clinical applications. Supported in part by Free to Breathe Young Investigator Research Grant and NIH/NCI R01 CA 093626. The authors thank Philips Radiation Oncology Systems for the Pinnacle3 treatment planning systems.« less

  8. A comparative study of the target volume definition in radiotherapy with «Slow CT Scan» vs. 4D PET/CT Scan in early stages non-small cell lung cancer.

    PubMed

    Molla, M; Anducas, N; Simó, M; Seoane, A; Ramos, M; Cuberas-Borros, G; Beltran, M; Castell, J; Giralt, J

    To evaluate the use of 4D PET/CT to quantify tumor respiratory motion compared to the «Slow»-CT (CTs) in the radiotherapy planning process. A total of 25 patients with inoperable early stage non small cell lung cancer (NSCLC) were included in the study. Each patient was imaged with a CTs (4s/slice) and 4D PET/CT. The adequacy of each technique for respiratory motion capture was evaluated using the volume definition for each of the following: Internal target volume (ITV) 4D and ITVslow in relation with the volume defined by the encompassing volume of 4D PET/CT and CTs (ITVtotal). The maximum distance between the edges of the volume defined by each technique to that of the total volume was measured in orthogonal beam's eye view. The ITV4D showed less differences in relation with the ITVtotal in both the cranio-caudal and the antero-posterior axis compared to the ITVslow. The maximum differences were 0.36mm in 4D PET/CTand 0.57mm in CTs in the antero-posterior axis. 4D PET/CT resulted in the definition of more accurate (ITV4D/ITVtotal 0.78 vs. ITVs/ITVtotal 0.63), and larger ITVs (19.9 cc vs. 16.3 cc) than those obtained with CTs. Planning with 4D PET/CT in comparison with CTs, allows incorporating tumor respiratory motion and improving planning radiotherapy of patients in early stages of lung cancer. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  9. Audit of radiation dose delivered in time-resolved four-dimensional computed tomography in a radiotherapy department.

    PubMed

    Hubbard, Patricia; Callahan, Jason; Cramb, Jim; Budd, Ray; Kron, Tomas

    2015-06-01

    To review the dose delivered to patients in time-resolved computed tomography (4D CT) used for radiotherapy treatment planning. 4D CT is used at Peter MacCallum Cancer Centre since July 2007 for radiotherapy treatment planning using a Philips Brilliance Wide Bore CT scanner (16 slice, helical 4D CT acquisition). All scans are performed at 140 kVp and reconstructed in 10 datasets for different phases of the breathing cycle. Dose records were analysed retrospectively for 387 patients who underwent 4D CT procedures between 2007 and 2013. A total of 444 4D CT scans were acquired with the majority of them (342) being for lung cancer radiotherapy. Volume CT dose index (CTDIvol) as recorded over this period was fairly constant at approximately 20 mGy for adults. The CTDI for 4D CT for lung cancers of 19.6 ± 9.3 mGy (n = 168, mean ± 1SD) was found to be 63% higher than CTDIs for conventional CT scans for lung patients that were acquired in the same period (CTDIvol 12 ± 4 mGy, sample of n = 25). CTDI and dose length product (DLP) increased with increasing field of view; however, no significant difference between DLPs for different indications (breast, kidney, liver and lung) could be found. Breathing parameters such as breathing rate or pattern did not affect dose. 4D CT scans can be acquired for radiotherapy treatment planning with a dose less than twice the one required for conventional CT scanning. © 2015 The Royal Australian and New Zealand College of Radiologists.

  10. Modeling respiratory motion for reducing motion artifacts in 4D CT images.

    PubMed

    Zhang, Yongbin; Yang, Jinzhong; Zhang, Lifei; Court, Laurence E; Balter, Peter A; Dong, Lei

    2013-04-01

    Four-dimensional computed tomography (4D CT) images have been recently adopted in radiation treatment planning for thoracic and abdominal cancers to explicitly define respiratory motion and anatomy deformation. However, significant image distortions (artifacts) exist in 4D CT images that may affect accurate tumor delineation and the shape representation of normal anatomy. In this study, the authors present a patient-specific respiratory motion model, based on principal component analysis (PCA) of motion vectors obtained from deformable image registration, with the main goal of reducing image artifacts caused by irregular motion during 4D CT acquisition. For a 4D CT image set of a specific patient, the authors calculated displacement vector fields relative to a reference phase, using an in-house deformable image registration method. The authors then used PCA to decompose each of the displacement vector fields into linear combinations of principal motion bases. The authors have demonstrated that the regular respiratory motion of a patient can be accurately represented by a subspace spanned by three principal motion bases and their projections. These projections were parameterized using a spline model to allow the reconstruction of the displacement vector fields at any given phase in a respiratory cycle. Finally, the displacement vector fields were used to deform the reference CT image to synthesize CT images at the selected phase with much reduced image artifacts. The authors evaluated the performance of the in-house deformable image registration method using benchmark datasets consisting of ten 4D CT sets annotated with 300 landmark pairs that were approved by physicians. The initial large discrepancies across the landmark pairs were significantly reduced after deformable registration, and the accuracy was similar to or better than that reported by state-of-the-art methods. The proposed motion model was quantitatively validated on 4D CT images of a phantom and a lung cancer patient by comparing the synthesized images and the original images at different phases. The synthesized images matched well with the original images. The motion model was used to reduce irregular motion artifacts in the 4D CT images of three lung cancer patients. Visual assessment indicated that the proposed approach could reduce severe image artifacts. The shape distortions around the diaphragm and tumor regions were mitigated in the synthesized 4D CT images. The authors have derived a mathematical model to represent the regular respiratory motion from a patient-specific 4D CT set and have demonstrated its application in reducing irregular motion artifacts in 4D CT images. The authors' approach can mitigate shape distortions of anatomy caused by irregular breathing motion during 4D CT acquisition.

  11. Audio-Visual Biofeedback Does Not Improve the Reliability of Target Delineation Using Maximum Intensity Projection in 4-Dimensional Computed Tomography Radiation Therapy Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Wei, E-mail: wlu@umm.edu; Neuner, Geoffrey A.; George, Rohini

    2014-01-01

    Purpose: To investigate whether coaching patients' breathing would improve the match between ITV{sub MIP} (internal target volume generated by contouring in the maximum intensity projection scan) and ITV{sub 10} (generated by combining the gross tumor volumes contoured in 10 phases of a 4-dimensional CT [4DCT] scan). Methods and Materials: Eight patients with a thoracic tumor and 5 patients with an abdominal tumor were included in an institutional review board-approved prospective study. Patients underwent 3 4DCT scans with: (1) free breathing (FB); (2) coaching using audio-visual (AV) biofeedback via the Real-Time Position Management system; and (3) coaching via a spirometer systemmore » (Active Breathing Coordinator or ABC). One physician contoured all scans to generate the ITV{sub 10} and ITV{sub MIP}. The match between ITV{sub MIP} and ITV{sub 10} was quantitatively assessed with volume ratio, centroid distance, root mean squared distance, and overlap/Dice coefficient. We investigated whether coaching (AV or ABC) or uniform expansions (1, 2, 3, or 5 mm) of ITV{sub MIP} improved the match. Results: Although both AV and ABC coaching techniques improved frequency reproducibility and ABC improved displacement regularity, neither improved the match between ITV{sub MIP} and ITV{sub 10} over FB. On average, ITV{sub MIP} underestimated ITV{sub 10} by 19%, 19%, and 21%, with centroid distance of 1.9, 2.3, and 1.7 mm and Dice coefficient of 0.87, 0.86, and 0.88 for FB, AV, and ABC, respectively. Separate analyses indicated a better match for lung cancers or tumors not adjacent to high-intensity tissues. Uniform expansions of ITV{sub MIP} did not correct for the mismatch between ITV{sub MIP} and ITV{sub 10}. Conclusions: In this pilot study, audio-visual biofeedback did not improve the match between ITV{sub MIP} and ITV{sub 10}. In general, ITV{sub MIP} should be limited to lung cancers, and modification of ITV{sub MIP} in each phase of the 4DCT data set is recommended.« less

  12. Building without a plan: the career experiences of Australian strength and conditioning coaches.

    PubMed

    Dawson, Andrew J; Leonard, Zane M; Wehner, Kylie A; Gastin, Paul B

    2013-05-01

    The purpose of this investigation was to explore the career experiences of Australian strength and conditioning coaches. Six Australian strength and conditioning coaches (mean age = 33.7 years, SD = 6.0 years) with a mean of 10.4 (SD = 4.9) years experience working with elite Olympic and professional athletes were interviewed about their experiences of career development. Each interview was transcribed verbatim and analyzed to produce key themes and subthemes relating to (a) work environments, (b) sport management practice, (c) career development processes, and (d) career building strategies. The work environments of Australian strength and conditioning coaches were found to be poor because of long working hours and irregular human resource policy and management practices of sport organizations. Because of the volatile and unpredictable nature of their working conditions, the coaches interviewed have only a short-term view of their career creating considerable stress in their lives. The coaches interviewed found it difficult to develop their careers because their only options were self-supported and self-funded professional development activities. The coaches in this study believed that more needed to be done at a policy and management level by sport organizations and their professional body to enhance the career development of strength and conditioning coaches because they play a key role in both athlete and sport organization performance. These results may help sport organizations develop policies and management practices that enhance the careers of strength and conditioning coaches and will have important practical implications for the education and development of sport professionals.

  13. A study on quantitative analysis of field size and dose by using gating system in 4D conformal radiation treatment

    NASA Astrophysics Data System (ADS)

    Ji, Youn-Sang; Dong, Kyung-Rae; Kim, Chang-Bok; Chung, Woon-Kwan; Cho, Jae-Hwan; Lee, Hae-Kag

    2012-10-01

    This study evaluated the gating-based 4-D conformal radiation therapy (4D-CT) treatment planning by a comparison with the common 3-D conformal radiation therapy (3D-CT) treatment planning and examined the change in treatment field size and dose to the tumors and adjacent normal tissues because an unnecessary dose is also included in the 3-D treatment planning for the radiation treatment of tumors in the chest and abdomen. The 3D-CT and gating-based 4D-CT images were obtained from patients who had undergone radiation treatment for chest and abdomen tumors in the oncology department. After establishing a treatment plan, the CT treatment and planning system were used to measure the change in field size for analysis. A dose volume histogram (DVH) was used to calculate the appropriate dose to planning target volume (PTV) tumors and adjacent normal tissue. The difference in the treatment volume of the chest was 0.6 and 0.83 cm on the X- and Y-axis, respectively, for the gross tumor volume (GTV). Accordingly, the values in the 4D-CT treatment planning were smaller and the dose was more concentrated by 2.7% and 0.9% on the GTV and clinical target volume (CTV), respectively. The normal tissues in the surrounding normal tissues were reduced by 3.0%, 7.2%, 0.4%, 1.7%, 2.6% and 0.2% in the bronchus, chest wall, esophagus, heart, lung and spinal cord, respectively. The difference in the treatment volume of the abdomen was 0.72 cm on the X-axis and 0.51 cm on the Y-axis for the GTV; and 1.06 cm on the X-axis and 1.85 cm on the Y-axis for the PTV. Therefore, the values in the 4D-CT treatment planning were smaller. The dose was concentrated by 6.8% and 4.3% on the GTV and PTV, respectively, whereas the adjacent normal tissues in the cord, Lt. kidney, Rt. kidney, small bowels and whole liver were reduced by 3.2%, 4.2%, 1.5%, 6.2% and 12.7%, respectively. The treatment field size was smaller in volume in the case of the 4D-CT treatment planning. In the DVH, the 4D-CT treatment planning showed a higher dose concentration on the part to be treated than the 3D-CT treatment planning with a lower dose to the adjacent normal tissues. Overall, the gating-based 4D-CT treatment planning is believed to be more helpful than the 3D-CT treatment planning.

  14. 4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling.

    PubMed

    Yang, Deshan; Lu, Wei; Low, Daniel A; Deasy, Joseph O; Hope, Andrew J; El Naqa, Issam

    2008-10-01

    Four-dimensional computed tomography (4D-CT) imaging technology has been developed for radiation therapy to provide tumor and organ images at the different breathing phases. In this work, a procedure is proposed for estimating and modeling the respiratory motion field from acquired 4D-CT imaging data and predicting tissue motion at the different breathing phases. The 4D-CT image data consist of series of multislice CT volume segments acquired in ciné mode. A modified optical flow deformable image registration algorithm is used to compute the image motion from the CT segments to a common full volume 3D-CT reference. This reference volume is reconstructed using the acquired 4D-CT data at the end-of-exhalation phase. The segments are optimally aligned to the reference volume according to a proposed a priori alignment procedure. The registration is applied using a multigrid approach and a feature-preserving image downsampling maxfilter to achieve better computational speed and higher registration accuracy. The registration accuracy is about 1.1 +/- 0.8 mm for the lung region according to our verification using manually selected landmarks and artificially deformed CT volumes. The estimated motion fields are fitted to two 5D (spatial 3D+tidal volume+airflow rate) motion models: forward model and inverse model. The forward model predicts tissue movements and the inverse model predicts CT density changes as a function of tidal volume and airflow rate. A leave-one-out procedure is used to validate these motion models. The estimated modeling prediction errors are about 0.3 mm for the forward model and 0.4 mm for the inverse model.

  15. 78 FR 69932 - Tedesco Family ESB Trust, et al.-Purchase of Certain Assets and Membership Interests-Evergreen...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-21

    ... Trails, Inc. d/b/a Horizon Coach Lines, et al. AGENCY: Surface Transportation Board, DOT. ACTION: Notice... Franmar's purchase of certain motor coach and non- motor coach assets of Evergreen Trails, Inc. d/b/a...

  16. The First Class Questionnaire, Class of 1981

    DTIC Science & Technology

    1981-06-01

    Classroom instruction 16.8 13.4 16.9 E. Cadet coaches 6.3 7.2 7.2 F. Other: __18.8 13.4 13.9 20. In my opinion, for me to improve my writing skills aL West...D. Other Ladets 16.9 17.8 16.0 E. My Company Tactical Officer 0.5 0.9 0 F. Other Staff & Faculty members such as instructors, sponsors, coaches 14.4...important -6 6& B. Major importance f3 C- I-Portant -71i5 .. Mie importance 14 E. importance 39 F Not applicable l.i- 716 (53C). Cadet Leadership Training

  17. Segmentation and tracking of lung nodules via graph-cuts incorporating shape prior and motion from 4D CT.

    PubMed

    Cha, Jungwon; Farhangi, Mohammad Mehdi; Dunlap, Neal; Amini, Amir A

    2018-01-01

    We have developed a robust tool for performing volumetric and temporal analysis of nodules from respiratory gated four-dimensional (4D) CT. The method could prove useful in IMRT of lung cancer. We modified the conventional graph-cuts method by adding an adaptive shape prior as well as motion information within a signed distance function representation to permit more accurate and automated segmentation and tracking of lung nodules in 4D CT data. Active shape models (ASM) with signed distance function were used to capture the shape prior information, preventing unwanted surrounding tissues from becoming part of the segmented object. The optical flow method was used to estimate the local motion and to extend three-dimensional (3D) segmentation to 4D by warping a prior shape model through time. The algorithm has been applied to segmentation of well-circumscribed, vascularized, and juxtapleural lung nodules from respiratory gated CT data. In all cases, 4D segmentation and tracking for five phases of high-resolution CT data took approximately 10 min on a PC workstation with AMD Phenom II and 32 GB of memory. The method was trained based on 500 breath-held 3D CT data from the LIDC data base and was tested on 17 4D lung nodule CT datasets consisting of 85 volumetric frames. The validation tests resulted in an average Dice Similarity Coefficient (DSC) = 0.68 for all test data. An important by-product of the method is quantitative volume measurement from 4D CT from end-inspiration to end-expiration which will also have important diagnostic value. The algorithm performs robust segmentation of lung nodules from 4D CT data. Signed distance ASM provides the shape prior information which based on the iterative graph-cuts framework is adaptively refined to best fit the input data, preventing unwanted surrounding tissue from merging with the segmented object. © 2017 American Association of Physicists in Medicine.

  18. Nutrition-focused wellness coaching promotes a reduction in body weight in overweight US veterans.

    PubMed

    Shahnazari, Mohammad; Ceresa, Carol; Foley, Sharon; Fong, Angela; Zidaru, Elena; Moody, Sandra

    2013-07-01

    Diet plays a critical role in the pathogenesis of major chronic diseases common in populations of US veterans. The role of nutrition-focused wellness coaching in improving dietary behavior and/or reducing weight in overweight and obese US veterans is not known. At the San Francisco Veterans Affairs Medical Center, US veterans aged 25 to 80 years were randomized to receive nutrition coaching on eating behaviors at baseline only (control group, n=22) or an additional eight times over the course of 6 months (intervention group, n=28) in 2010-2011. Multiple coaching contacts decreased intake of energy, fat, and carbohydrate by 31% (P≤0.001) as evaluated by the 2005 Block food frequency questionnaire, which is composed of 111 food items. A weight loss of 5% from baseline (92.8 to 88.2 kg; P<0.01) was observed in the intervention group with mean body mass index decreasing from 30.4 to 28.9 (P<0.05). The control group showed a decrease in fat intake by 20% (P=0.01), but no statistically significant changes in intake of other nutrients or body weight (88.7 to 87.4 kg). Those in the intervention group reported diets at follow-up that were lower in cholesterol, saturated fat, sodium, sugar (P≤0.01), calcium (P< 0.05), and vitamin D (P<0.01), although when adjusted for energy (ie, nutrient density) calcium intake increased and vitamin D remained unchanged. Veterans' readiness to change eating behavior for weight loss improved with nutrition coaching. This study demonstrates that intermittent nutrition coaching can be an effective strategy to promote reductions in energy intake, body weight, and body mass index in overweight US veterans. Further research is needed to determine whether nutrition coaching improves other clinical outcomes and sustains weight loss. Copyright © 2013 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  19. TH-E-17A-07: Improved Cine Four-Dimensional Computed Tomography (4D CT) Acquisition and Processing Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castillo, S; Castillo, R; Castillo, E

    2014-06-15

    Purpose: Artifacts arising from the 4D CT acquisition and post-processing methods add systematic uncertainty to the treatment planning process. We propose an alternate cine 4D CT acquisition and post-processing method to consistently reduce artifacts, and explore patient parameters indicative of image quality. Methods: In an IRB-approved protocol, 18 patients with primary thoracic malignancies received a standard cine 4D CT acquisition followed by an oversampling 4D CT that doubled the number of images acquired. A second cohort of 10 patients received the clinical 4D CT plus 3 oversampling scans for intra-fraction reproducibility. The clinical acquisitions were processed by the standard phasemore » sorting method. The oversampling acquisitions were processed using Dijkstras algorithm to optimize an artifact metric over available image data. Image quality was evaluated with a one-way mixed ANOVA model using a correlation-based artifact metric calculated from the final 4D CT image sets. Spearman correlations and a linear mixed model tested the association between breathing parameters, patient characteristics, and image quality. Results: The oversampling 4D CT scans reduced artifact presence significantly by 27% and 28%, for the first cohort and second cohort respectively. From cohort 2, the inter-replicate deviation for the oversampling method was within approximately 13% of the cross scan average at the 0.05 significance level. Artifact presence for both clinical and oversampling methods was significantly correlated with breathing period (ρ=0.407, p-value<0.032 clinical, ρ=0.296, p-value<0.041 oversampling). Artifact presence in the oversampling method was significantly correlated with amount of data acquired, (ρ=-0.335, p-value<0.02) indicating decreased artifact presence with increased breathing cycles per scan location. Conclusion: The 4D CT oversampling acquisition with optimized sorting reduced artifact presence significantly and reproducibly compared to the phase-sorted clinical acquisition.« less

  20. Multi-phase simultaneous segmentation of tumor in lung 4D-CT data with context information.

    PubMed

    Shen, Zhengwen; Wang, Huafeng; Xi, Weiwen; Deng, Xiaogang; Chen, Jin; Zhang, Yu

    2017-01-01

    Lung 4D computed tomography (4D-CT) plays an important role in high-precision radiotherapy because it characterizes respiratory motion, which is crucial for accurate target definition. However, the manual segmentation of a lung tumor is a heavy workload for doctors because of the large number of lung 4D-CT data slices. Meanwhile, tumor segmentation is still a notoriously challenging problem in computer-aided diagnosis. In this paper, we propose a new method based on an improved graph cut algorithm with context information constraint to find a convenient and robust approach of lung 4D-CT tumor segmentation. We combine all phases of the lung 4D-CT into a global graph, and construct a global energy function accordingly. The sub-graph is first constructed for each phase. A context cost term is enforced to achieve segmentation results in every phase by adding a context constraint between neighboring phases. A global energy function is finally constructed by combining all cost terms. The optimization is achieved by solving a max-flow/min-cut problem, which leads to simultaneous and robust segmentation of the tumor in all the lung 4D-CT phases. The effectiveness of our approach is validated through experiments on 10 different lung 4D-CT cases. The comparison with the graph cut without context constraint, the level set method and the graph cut with star shape prior demonstrates that the proposed method obtains more accurate and robust segmentation results.

  1. Four-Dimensional Magnetic Resonance Imaging With 3-Dimensional Radial Sampling and Self-Gating–Based K-Space Sorting: Early Clinical Experience on Pancreatic Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Wensha, E-mail: wensha.yang@cshs.org; Fan, Zhaoyang; Tuli, Richard

    2015-12-01

    Purpose: To apply a novel self-gating k-space sorted 4-dimensional MRI (SG-KS-4D-MRI) method to overcome limitations due to anisotropic resolution and rebinning artifacts and to monitor pancreatic tumor motion. Methods and Materials: Ten patients were imaged using 4D-CT, cine 2-dimensional MRI (2D-MRI), and the SG-KS-4D-MRI, which is a spoiled gradient recalled echo sequence with 3-dimensional radial-sampling k-space projections and 1-dimensional projection-based self-gating. Tumor volumes were defined on all phases in both 4D-MRI and 4D-CT and then compared. Results: An isotropic resolution of 1.56 mm was achieved in the SG-KS-4D-MRI images, which showed superior soft-tissue contrast to 4D-CT and appeared to be free of stitchingmore » artifacts. The tumor motion trajectory cross-correlations (mean ± SD) between SG-KS-4D-MRI and cine 2D-MRI in superior–inferior, anterior–posterior, and medial–lateral directions were 0.93 ± 0.03, 0.83 ± 0.10, and 0.74 ± 0.18, respectively. The tumor motion trajectories cross-correlations between SG-KS-4D-MRI and 4D-CT in superior–inferior, anterior–posterior, and medial–lateral directions were 0.91 ± 0.06, 0.72 ± 0.16, and 0.44 ± 0.24, respectively. The average standard deviation of gross tumor volume calculated from the 10 breathing phases was 0.81 cm{sup 3} and 1.02 cm{sup 3} for SG-KS-4D-MRI and 4D-CT, respectively (P=.012). Conclusions: A novel SG-KS-4D-MRI acquisition method capable of reconstructing rebinning artifact–free, high-resolution 4D-MRI images was used to quantify pancreas tumor motion. The resultant pancreatic tumor motion trajectories agreed well with 2D-cine-MRI and 4D-CT. The pancreatic tumor volumes shown in the different phases for the SG-KS-4D-MRI were statistically significantly more consistent than those in the 4D-CT.« less

  2. SU-E-T-428: Feasibility Study of 4D Image Reconstruction by Organ Motion Vector Extension Based On Portal Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoon, J; Jung, J; Yeo, I

    2015-06-15

    Purpose: To develop and to test a method to generate a new 4D CT images of the treatment day from the old 4D CT and the portal images of the day when the motion extent exceeded from that represented by plan CTs. Methods: A motion vector of a moving tumor in a patient may be extended to reconstruct the tumor position when the motion extent exceeded from that represented by plan CTs. To test this, 1. a phantom that consists of a polystyrene cylinder (tumor) embedded in cork (lung) was placed on a moving platform with 4 sec/cycle and amplitudesmore » of 1 cm and 2 cm, and was 4D-scanned. 2. A 6MV photon beam was irradiated on the moving phantoms and cineEPID images were obtained. 3. A motion vector of the tumor was acquired from 4D CT images of the phantom with 1 cm amplitude. 4. From cine EPID images of the phantom with the 2 cm amplitude, various motion extents (0.3 cm, 0.5 cm, etc) were acquired and programmed into the motion vector, producing CT images at each position. 5. The reconstructed CT images were then compared with pre-acquired “reference” 4D CT images at each position (i.e. phase). Results: The CT image was reconstructed and compared with the reference image, showing a slight mismatch in the transition direction limited by voxel size (slice thickness) in CT image. Due to the rigid nature of the phantom studied, the modeling the displacement of the center of object was sufficient. When deformable tumors are to be modeled, more complex scheme is necessary, which utilize cine EPID and 4D CT images. Conclusion: The new idea of CT image reconstruction was demonstrated. Deformable tumor movements need to be considered in the future.« less

  3. Regional Lung Ventilation Analysis Using Temporally Resolved Magnetic Resonance Imaging.

    PubMed

    Kolb, Christoph; Wetscherek, Andreas; Buzan, Maria Teodora; Werner, René; Rank, Christopher M; Kachelrie, Marc; Kreuter, Michael; Dinkel, Julien; Heuel, Claus Peter; Maier-Hein, Klaus

    We propose a computer-aided method for regional ventilation analysis and observation of lung diseases in temporally resolved magnetic resonance imaging (4D MRI). A shape model-based segmentation and registration workflow was used to create an atlas-derived reference system in which regional tissue motion can be quantified and multimodal image data can be compared regionally. Model-based temporal registration of the lung surfaces in 4D MRI data was compared with the registration of 4D computed tomography (CT) images. A ventilation analysis was performed on 4D MR images of patients with lung fibrosis; 4D MR ventilation maps were compared with corresponding diagnostic 3D CT images of the patients and 4D CT maps of subjects without impaired lung function (serving as reference). Comparison between the computed patient-specific 4D MR regional ventilation maps and diagnostic CT images shows good correlation in conspicuous regions. Comparison to 4D CT-derived ventilation maps supports the plausibility of the 4D MR maps. Dynamic MRI-based flow-volume loops and spirograms further visualize the free-breathing behavior. The proposed methods allow for 4D MR-based regional analysis of tissue dynamics and ventilation in spontaneous breathing and comparison of patient data. The proposed atlas-based reference coordinate system provides an automated manner of annotating and comparing multimodal lung image data.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan, J; Lin, T; Jin, L

    Purpose: Liver SBRT patients unable to tolerate breath-hold for radiotherapy are treated free-breathing with image guidance. Target localization using 3D CBCT requires extra margins to accommodate the respiratory motion. The purpose of this study is to evaluate the accuracy and reproducibility of 4D CT-on-rails in target localization for free-breathing liver SBRT. Methods: A Siemens SOMATOM CT-on-Rails 4D with Anzai Pressure Belt system was used both as the simulation and the localization CT. Fiducial marker was placed close to the center of the target prior to the simulation. Amplitude based sorting was used in the scan. Eight or sixteen phases ofmore » reconstructed CT sets (depends on breathing pattern) can be sent to Velocity to create the maximum intensity projection (MIP) image set. Target ITV and fiducial ITV were drawn based on the MIP image. In patient localization, a 4D scan was taken with the same settings as the sim scan. Images were registered to match fiducial ITVs. Results: Ten liver cancer patients treated for 50Gy over 5 fractions, with amplitudes of breathing motion ranging from 4.3–14.5 mm, were analyzed in this study. Results show that the Intra & inter fraction variability in liver motion amplitude significantly less than the baseline inter-fraction shifts in liver position. 90% of amplitude change is less than 3 mm. The differences in the D99 and D95 GTV dose coverage between the 4D CT-on-Rails and the CBCT plan were small (within 5%) for all the selected cases. However, the average PTV volume by using the 4D CT-on-Rails is 37% less than the CBCT PTV volume. Conclusion: Simulation and Registration using 4D CT-on-Rails provides accurate target localization and is unaffected by larger breathing amplitudes as seen with 3D CBCT image registration. Localization with 4D CT-on-Rails can significantly reduce the PTV volume with sufficient tumor.« less

  5. Excellence in Coaching: The Art and Skill of Elite Practitioners

    ERIC Educational Resources Information Center

    Nash, Christine S.; Sproule, John; Horton, Peter

    2011-01-01

    During this study, 10 expert coaches were interviewed to examine their views on aspects of their individual coaching practice. Four themes emerged from the interviews: (a) the long-term approach, (b) the authentic coaching environment, (c) creating a learning environment, and (d) the quality and quantity of training sessions. These coaches were…

  6. Coaching with Parents in Early Intervention: An Interdisciplinary Research Synthesis

    ERIC Educational Resources Information Center

    Kemp, Peggy; Turnbull, Ann P.

    2014-01-01

    The purpose of this article was to synthesize intervention studies using coaching with parents in early intervention with a focus on (a) definitions and descriptions of coaching with parents; (b) characteristics of families and coaches; (c) parameters such as settings, contexts, dosage, and professional development related to coaching; and (d)…

  7. Semiautomated thyroid volumetry using 3D CT: prospective comparison with measurements obtained using 2D ultrasound, 2D CT, and water displacement method of specimen.

    PubMed

    Lee, Sun Jin; Chong, Semin; Kang, Kyung Ho; Hur, Joonho; Hong, Byung-Woo; Kim, Hyun Jung; Kim, Soo Jin

    2014-11-01

    The objective of our study was to measure thyroid volumes using semiautomated 3D CT and to compare the 3D CT volumes with volumes measured using 2D ultrasound, 2D CT, and the water displacement method. In 47 patients, 2D ultrasound volumes and 2D CT volumes of the thyroid gland were estimated using the ellipsoid volume formula, and 3D CT volumes were calculated using semiautomated reconstructive techniques. All volume data were compared with thyroid specimen volumes obtained using the water displacement method and were statistically analyzed using the one-way ANOVA, the Pearson correlation coefficient (R), linear regression, and the concordance correlation coefficient (CCC). The processing time of semiautomated 3D CT thyroid volumetry was measured. The paired mean differences ± SD between the three imaging-determined volumes and the specimen volumes were 0.8 ± 3.1 mL for 2D ultrasound, 4.0 ± 4.7 mL for 2D CT, and 0.2 ± 2.5 mL for 3D CT. A significant difference in the mean thyroid volume was found between 2D CT and specimen volumes (p = 0.016) compared with the other pairs (p = 0.937 for 2D ultrasound mean volume vs specimen mean volume, and p = 0.999 for 3D CT mean volume vs specimen mean volume). Between specimen volume and 2D ultrasound volume, specimen volume and 2D CT volume, and specimen volume and 3D CT volume, R values were 0.885, 0.724, and 0.929, respectively, and CCC values were 0.876, 0.598, and 0.925, respectively. The mean processing time of semiautomated 3D CT thyroid volumetry was 7.0 minutes. Thyroid volumes measured using 2D ultrasound or semiautomated 3D CT are substantially close to thyroid specimen volumes measured using the water displacement method. Semiautomated 3D CT thyroid volumetry can provide a more reliable measure of thyroid volume than 2D ultrasound.

  8. Time-Adjusted Internal Target Volume: A Novel Approach Focusing on Heterogeneity of Tumor Motion Based on 4-Dimensional Computed Tomography Imaging for Radiation Therapy Planning of Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nishibuchi, Ikuno; Department of Radiation Oncology, Hiroshima Prefectural Hospital, Hiroshima; Kimura, Tomoki, E-mail: tkkimura@hiroshima-u.ac.jp

    2014-08-01

    Purpose: To consider nonuniform tumor motion within the internal target volume (ITV) by defining time-adjusted ITV (TTV), a volume designed to include heterogeneity of tumor existence on the basis of 4-dimensional computed tomography (4D-CT). Methods and Materials: We evaluated 30 lung cancer patients. Breath-hold CT (BH-CT) and free-breathing 4D-CT scans were acquired for each patient. The tumors were manually delineated using a lung CT window setting (window, 1600 HU; level, −300 HU). Tumor in BH-CT images was defined as gross tumor volume (GTV), and the sum of tumors in 4D-CT images was defined as ITV-4D. The TTV images were generatedmore » from the 4D-CT datasets, and the tumor existence probability within ITV-4D was calculated. We calculated the TTV{sub 80} value, which is the percentage of the volume with a tumor existence probability that exceeded 80% on ITV-4D. Several factors that affected the TTV{sub 80} value, such as the ITV-4D/GTV ratio or tumor centroid deviation, were evaluated. Results: Time-adjusted ITV images were acquired for all patients, and tumor respiratory motion heterogeneity was visualized. The median (range) ITV-4D/GTV ratio and median tumor centroid deviation were 1.6 (1.0-4.1) and 6.3 mm (0.1-30.3 mm), respectively. The median TTV{sub 80} value was 43.3% (2.9-98.7%). Strong correlations were observed between the TTV{sub 80} value and the ITV-4D/GTV ratio (R=−0.71) and tumor centroid deviation (R=−0.72). The TTV images revealed the tumor motion pattern features within ITV. Conclusions: The TTV images reflected nonuniform tumor motion, and they revealed the tumor motion pattern features, suggesting that the TTV concept may facilitate various aspects of radiation therapy planning of lung cancer while incorporating respiratory motion in the future.« less

  9. SU-F-T-636: Comprehensive Approach to Motion Assessment for Liver and Pancreas SBRT Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halvorsen, P; Iftimia, I; Hunter, K

    2016-06-15

    Purpose: Our past practice for liver and pancreas SBRT consisted of free breathing (FB) with gated treatment delivery using a 30-70% phase window. We have recently adopted an assessment method leading to individualized motion management to minimize target motion. We present our results from 47 patients treated with this new approach. Methods: We perform an initial patient coaching and assessment session in our conventional simulator suite to observe the motion of the implanted fiducials with FB anterior and lateral 20-second cine acquisitions. The physician decides whether to attempt inhale or exhale breath-hold (BH). The patient is coached while observing withmore » cine to ascertain their ability to achieve the desired BH mode for long periods as needed for treatment delivery. If the patient cannot comply, a FB approach is adopted using gating or simple ITV method (for patients without fiducials). After achieving a patient-specific motion management mode, we perform CT-simulation using the Varian RPM system to reproduce the chosen mode and record a reference session for treatment delivery. For pre-treatment imaging, the fiducials are observed under fluoro while coaching the patient. Results: Of 47 SBRT cases analyzed, 32 were liver and 15 were pancreas. The chosen techniques were: 32 exhale BH (12 with abdominal compression), 7 FB gated, 4 inhale BH, and 4 FB ITV. Maximum fiducial motion amplitude was 5 mm for the FB gated patients, and less than 5 mm for all BH patients with most able to achieve a maximum amplitude of 3 mm. Conclusion: This study showed that an individualized motion management approach can reduce the target volume and, therefore, the volume of irradiated healthy tissue from liver or pancreas SBRT. Effective coaching is essential in achieving consistent BH with 3 mm amplitude. The fluoro/cine session is helpful in establishing the right coaching approach for each patient.« less

  10. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis

    NASA Astrophysics Data System (ADS)

    Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas

    2012-04-01

    To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between clinically acquired SPECT perfusion and specific ventilation from 4D CT. Results suggest high correlation between methods within the sub-population of lung cancer patients with malignant airway stenosis.

  11. Mutations in 3 genes (MKS3, CC2D2A and RPGRIP1L) cause COACH syndrome (Joubert syndrome with congenital hepatic fibrosis)

    PubMed Central

    Doherty, D; Parisi, M A; Finn, L S; Gunay-Aygun, M; Al-Mateen, M; Bates, D; Clericuzio, C; Demir, H; Dorschner, M; van Essen, A J; Gahl, W A; Gentile, M; Gorden, N T; Hikida, A; Knutzen, D; Özyurek, H; Phelps, I; Rosenthal, P; Verloes, A; Weigand, H; Chance, P F; Dobyns, W B; Glass, I A

    2011-01-01

    Objective To identify genetic causes of COACH syndrome Background COACH syndrome is a rare autosomal recessive disorder characterised by Cerebellar vermis hypoplasia, Oligophrenia (developmental delay/mental retardation), Ataxia, Coloboma, and Hepatic fibrosis. The vermis hypoplasia falls in a spectrum of mid-hindbrain malformation called the molar tooth sign (MTS), making COACH a Joubert syndrome related disorder (JSRD). Methods In a cohort of 251 families with JSRD, 26 subjects in 23 families met criteria for COACH syndrome, defined as JSRD plus clinically apparent liver disease. Diagnostic criteria for JSRD were clinical findings (intellectual impairment, hypotonia, ataxia) plus supportive brain imaging findings (MTS or cerebellar vermis hypoplasia). MKS3/TMEM67 was sequenced in all subjects for whom DNA was available. In COACH subjects without MKS3 mutations, CC2D2A, RPGRIP1L and CEP290 were also sequenced. Results 19/23 families (83%) with COACH syndrome carried MKS3 mutations, compared to 2/209 (1%) with JSRD but no liver disease. Two other families with COACH carried CC2D2A mutations, one family carried RPGRIP1L mutations, and one lacked mutations in MKS3, CC2D2A, RPGRIP1L and CEP290. Liver biopsies from three subjects, each with mutations in one of the three genes, revealed changes within the congenital hepatic fibrosis/ductal plate malformation spectrum. In JSRD with and without liver disease, MKS3 mutations account for 21/232 families (9%). Conclusions Mutations in MKS3 are responsible for the majority of COACH syndrome, with minor contributions from CC2D2A and RPGRIP1L; therefore, MKS3 should be the first gene tested in patients with JSRD plus liver disease and/or coloboma, followed by CC2D2A and RPGRIP1L. PMID:19574260

  12. [4D-CT-based plan target volume (PTV) definition compared with conventional PTV definition using general margin in radiotherapy for lung cancer].

    PubMed

    Ju, Xiao; Li, Minghui; Zhou, Zongmei; Zhang, Ke; Han, Wei; Fu, Guishan; Cao, Ying; Wang, Lyuhua

    2014-01-01

    To investigate the dosimetric benefit of 4D-CT in the planning target volume (PTV) definition process compared with conventional PTV definition using general margin in radiotherapy of lung cancer. A set of 4D-CT images and multiphase helical CT scans were obtained in 10 patients with lung cancer. The radiotherapeutic plans based on PTV determined by 4D-CT and in addition of general margin were performed, respectively. The 3D motion of the centroid of GTV and the 3D spatial motion vectors were calculated. The differences of the two kinds of PTVs, mean lung dose (MLD), V5,V10,V15,V20 of total lung, mean heart dose (MHD), V30 and V40 of heart, D99 and D95 were compared, and the correlation between them and the 3D spatial motion vector was analyzed. The PTV4D in eight patients were smaller than PTVconv, with a mean reduction of (13.0 ± 8.0)% (P = 0.018). In other two patients, whose respiration motion was great, PTV4D was larger than PTVconv. The mean 3D spatial motion vector of GTV centroid was (0.78 ± 0.72)cm. By using 4D-CT, the mean reduction of MLD was (8.6 ± 9.9)% (P = 0.037). V5, V10, V15, V20 of total lung were decreased averagely by (7.2 ± 10.5)%, (5.5 ± 8.9)%, (6.5 ± 8.4)% and (5.7 ± 7.4)%, respectively (P < 0.05 for all). There was a significant positive correlation between PTV4D/PTVconv and the 3D spatial motion vector of the GTV centroid (P = 0.008). A significant inverse correlation was found between D994D/D99conv and the 3D spatial motion vector of the GTV centroid (P = 0.002). D994D/D99conv, (MLDconv-MLD4D) /MLDconv, total lung (V5conv-V54D)/V5conv, total lung (V10conv-V104D)/V10conv, (MHDconv-MHD4D)/MHDconv, heart (V30conv-V304D)/V30conv were inversely correlated with PTV4D/PTVconv (P < 0.05 for all). 4D-CT can be used to evaluate the respiration motion of lung tumor accurately. The 4D-CT-based PTV definition and radiotherapeutic planing can reduce the volume of PTV in patients with small respiration motion, increase the intra-target dose, and decrease the dose of normal tissue sequentially. For patients with large respiration motion, especially those more than 1.5-2 cm, this method can avoid target miss, meanwhile, not increase the dose of normal tissue significantly.

  13. Implications of free breathing motion assessed by 4D-computed tomography on the delivered dose in radiotherapy for esophageal cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duma, Marciana Nona, E-mail: Marciana.Duma@mri.tum.de; Berndt, Johannes; Rondak, Ina-Christine

    2015-01-01

    The aim of this study was to assess the effect of breathing motion on the delivered dose in esophageal cancer 3-dimensional (3D)-conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric modulated arc therapy (VMAT). We assessed 16 patients with esophageal cancer. All patients underwent 4D-computed tomography (4D-CT) for treatment planning. For each of the analyzed patients, 1 3D-CRT, 1 IMRT, and 1 VMAT (RapidArc—RA) plan were calculated. Each of the 3 initial plans was recalculated on the 4D-CT (for the maximum free inspiration and maximum free expiration) to assess the effect of breathing motion. We assessed the minimum dose (D{sub min})more » and mean dose (D{sub mean}) to the esophagus within the planning target volume, the volume changes of the lungs, the D{sub mean} and the total lung volume receiving at least 40 Gy (V{sub 40}), and the V{sub 30}, V{sub 20}, V{sub 10}, and V{sub 5}. For the heart we assessed the D{sub mean} and the V{sub 25}. Over all techniques and all patients the change in D{sub mean} as compared with the planned D{sub mean} (planning CT [PCT]) to the esophagus was 0.48% in maximum free inspiration (CT-insp) and 0.55% in maximum free expiration (CT-exp). The D{sub min} CT-insp change was 0.86% and CT-exp change was 0.89%. The D{sub mean} change of the lungs (heart) was in CT-insp 1.95% (2.89%) and 3.88% (2.38%) in CT-exp. In all, 4 patients had a clinically relevant change of the dose (≥ 5% D{sub mean} to the heart and the lungs) between inspiration and expiration. These patients had a very cranially or caudally situated tumor. There are no relevant differences in the delivered dose to the regions of interest among the 3 techniques. Breathing motion management could be considered to achieve a better sparing of the lungs or heart in patients with cranially or caudally situated tumors.« less

  14. Accuracy of volume measurement using 3D ultrasound and development of CT-3D US image fusion algorithm for prostate cancer radiotherapy.

    PubMed

    Baek, Jihye; Huh, Jangyoung; Kim, Myungsoo; Hyun An, So; Oh, Yoonjin; Kim, DongYoung; Chung, Kwangzoo; Cho, Sungho; Lee, Rena

    2013-02-01

    To evaluate the accuracy of measuring volumes using three-dimensional ultrasound (3D US), and to verify the feasibility of the replacement of CT-MR fusion images with CT-3D US in radiotherapy treatment planning. Phantoms, consisting of water, contrast agent, and agarose, were manufactured. The volume was measured using 3D US, CT, and MR devices. A CT-3D US and MR-3D US image fusion software was developed using the Insight Toolkit library in order to acquire three-dimensional fusion images. The quality of the image fusion was evaluated using metric value and fusion images. Volume measurement, using 3D US, shows a 2.8 ± 1.5% error, 4.4 ± 3.0% error for CT, and 3.1 ± 2.0% error for MR. The results imply that volume measurement using the 3D US devices has a similar accuracy level to that of CT and MR. Three-dimensional image fusion of CT-3D US and MR-3D US was successfully performed using phantom images. Moreover, MR-3D US image fusion was performed using human bladder images. 3D US could be used in the volume measurement of human bladders and prostates. CT-3D US image fusion could be used in monitoring the target position in each fraction of external beam radiation therapy. Moreover, the feasibility of replacing the CT-MR image fusion to the CT-3D US in radiotherapy treatment planning was verified.

  15. A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol.

    PubMed

    Carnes, Greg; Gaede, Stewart; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim

    2009-04-07

    Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy chaining' all couch positions using the selected images until an entire 3D volume was produced. The algorithm produced 16 phase volumes to complete a 4D-CT dataset. Additional 4D-CT datasets were also produced using external marker amplitude and phase angle sorting methods. The image quality of the volumes produced by the different methods was quantified by calculating the mean difference of the sorted overlapping slices from adjacent couch positions. The NCC sorted images showed a significant decrease in the mean difference (p < 0.01) for the five patients.

  16. WE-AB-204-03: A Novel 3D Printed Phantom for 4D PET/CT Imaging and SIB Radiotherapy Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soultan, D; Murphy, J; Moiseenko, V

    Purpose: To construct and test a 3D printed phantom designed to mimic variable PET tracer uptake seen in lung tumor volumes. To assess segmentation accuracy of sub-volumes of the phantom following 4D PET/CT scanning with ideal and patient-specific respiratory motion. To plan, deliver and verify delivery of PET-driven, gated, simultaneous integrated boost (SIB) radiotherapy plans. Methods: A set of phantoms and inserts were designed and manufactured for a realistic representation of lung cancer gated radiotherapy steps from 4D PET/CT scanning to dose delivery. A cylindrical phantom (40x 120 mm) holds inserts for PET/CT scanning. The novel 3D printed insert dedicatedmore » to 4D PET/CT mimics high PET tracer uptake in the core and lower uptake in the periphery. This insert is a variable density porous cylinder (22.12×70 mm), ABS-P430 thermoplastic, 3D printed by uPrint SE Plus with inner void volume (5.5×42 mm). The square pores (1.8×1.8 mm2 each) fill 50% of outer volume, resulting in a 2:1 SUV ratio of PET-tracer in the void volume with respect to porous volume. A matching in size cylindrical phantom is dedicated to validate gated radiotherapy. It contains eight peripheral holes matching the location of the porous part of the 3D printed insert, and one central hole. These holes accommodate adaptors for Farmer-type ion chamber and cells vials. Results: End-to-end test were performed from 4D PET/CT scanning to transferring data to the planning system and target volume delineation. 4D PET/CT scans were acquired of the phantom with different respiratory motion patterns and gating windows. A measured 2:1 18F-FDG SUV ratio between inner void and outer volume matched the 3D printed design. Conclusion: The novel 3D printed phantom mimics variable PET tracer uptake typical of tumors. Obtained 4D PET/CT scans are suitable for segmentation, treatment planning and delivery in SIB gated treatments of NSCLC.« less

  17. Interfractional variability of respiration-induced esophageal tumor motion quantified using fiducial markers and four-dimensional cone-beam computed tomography.

    PubMed

    Jin, Peng; Hulshof, Maarten C C M; van Wieringen, Niek; Bel, Arjan; Alderliesten, Tanja

    2017-07-01

    To investigate the interfractional variability of respiration-induced esophageal tumor motion using fiducial markers and four-dimensional cone-beam computed tomography (4D-CBCT) and assess if a 4D-CT is sufficient for predicting the motion during the treatment. Twenty-four patients with 63 markers visible in the retrospectively reconstructed 4D-CBCTs were included. For each marker, we calculated the amplitude and trajectory of the respiration-induced motion. Possible time trends of the amplitude over the treatment course and the interfractional variability of amplitudes and trajectory shapes were assessed. Further, the amplitudes measured in the 4D-CT were compared to those in the 4D-CBCTs. The amplitude was largest in the cranial-caudal direction of the distal esophagus (mean: 7.1mm) and proximal stomach (mean: 7.8mm). No time trend was observed in the amplitude over the treatment course. The interfractional variability of amplitudes and trajectory shapes was limited (mean: ≤1.4mm). Moreover, small and insignificant deviation was found between the amplitudes quantified in the 4D-CT and in the 4D-CBCT (mean absolute difference: ≤1.0mm). The limited interfractional variability of amplitudes and trajectory shapes and small amplitude difference between 4D-CT-based and 4D-CBCT-based measurements imply that a single 4D-CT would be sufficient for predicting the respiration-induced esophageal tumor motion during the treatment course. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Coaching the Coach: A Program for Development of Faculty Portfolio Coaches.

    PubMed

    Kopechek, Jack; Bardales, Cheryl; Lash, A Todd; Walker, Curtis; Pfeil, Sheryl; Ledford, Cynthia H

    2017-01-01

    Faculty coaching is recognized as an essential element for effective use of portfolios in undergraduate medical education, yet best practices for training these coaches are uncertain. New portfolio coaches participated in a multifaceted training program that included orienting modules, a 7.5-hr training workshop featuring analysis of reflective writing, an Observed Structured Teaching Exercise (OSTE), and subsequent longitudinal coaches' meetings for timely task training. Four desired coaching skills were emphasized in the initial training: creating a safe environment, explicitly using performance data, asking questions that elicit reflection, and guiding the student to develop future goals and plans. We collected and analyzed several outcomes: (a) coaches' self-assessment at key intervals, (b) open-ended written responses to three coaching vignettes, (c) video recordings of the OSTE, and (d) subsequent student evaluation of the coach. In an attempt to capture learning from the workshop, both the responses to written vignettes and the video-recorded encounters were coded for presence or absence of the four desired skills. Our portfolio and coaching program was instituted as part of a major undergraduate medical education reform. A new cohort of 25 coaches is enrolled with each matriculating student class, and each coach is assigned to work individually with 8-10 students, forming a coaching relationship that continues over 4 years. Coaches are compensated at 5% full-time equivalent. On coach self-assessment, the majority of coaches reported significant improvement in their perceived ability to assess a student's level of reflection, enhance reflection, use performance data, and guide a student to develop goals and plans. After two semesters, coach perception of improved abilities persisted. Students rated coaches as excellent (82%), reporting that coaches created safe environments (99%), promoted insight (92%), and aided in goal setting (97%). Written responses to vignettes before the OSTE found that several coaches omitted desired behaviors; however, posttraining responses showed no discernable pattern of learning. Coding of the OSTE, in contrast, documented that all coaches demonstrated all four of the desired skills. Although coaches reported learning related to key skills, learning was not apparent when responses to written vignettes were examined. In contrast, skills were demonstrated in the OSTE, perhaps due to the added structured tasks as well as anticipation of feedback. In conclusion, this portfolio coach training program achieved its desired aim of providing students with portfolio coaches who demonstrated the desired skills, as reported by both coaches and students.

  19. 5. Historic American Buildings Survey (Fed.) Stanley P. Mixon, Photographer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Historic American Buildings Survey (Fed.) Stanley P. Mixon, Photographer Sept 16, 1940 (C) EXTERIOR, VIEW FROM REAR (SOUTH EAST) SHOWING COACH HOUSE AT RIGHT. - Watson-Bancroft House, Main Street, East Windsor Hill, Hartford County, CT

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Negahdar, M; Loo, B; Maxim, P

    Purpose: Elasticity may distinguish malignant from benign pulmonary nodules. To compare determining of malignant pulmonary nodule (MPN) elasticity from four dimensional computed tomography (4D CT) images versus inhale/exhale breath-hold CT images. Methods: We analyzed phase 00 and 50 of 4D CT and deep inhale and natural exhale of breath-hold CT images of 30 MPN treated with stereotactic ablative radiotherapy (SABR). The radius of the smallest MPN was 0.3 cm while the biggest one was 2.1 cm. An intensity based deformable image registration (DIR) workflow was applied to the 4D CT and breath-hold images to determine the volumes of the MPNsmore » and a 1 cm ring of surrounding lung tissue (ring) in each state. Next, an elasticity parameter was derived by calculating the ratio of the volume changes of MPN (exhale:inhale or phase50:phase00) to that of a 1 cm ring of lung tissue surrounding the MPN. The proposed formulation of elasticity enables us to compare volume changes of two different MPN in two different locations of lung. Results: The calculated volume ratio of MPNs from 4D CT (phase50:phase00) and breath-hold images (exhale:inhale) was 1.00±0.23 and 0.95±0.11, respectively. It shows the stiffness of MPN and comparably bigger volume changes of MPN in breath-hold images because of the deeper degree of inhalation. The calculated elasticity of MPNs from 4D CT and breath-hold images was 1.12±0.22 and 1.23±0.26, respectively. For five patients who have had two MPN in their lung, calculated elasticity of tumor A and tumor B follows same trend in both 4D CT and breath-hold images. Conclusion: We showed that 4D CT and breath-hold images are comparable in the ability to calculate the elasticity of MPN. This study has been supported by Department of Defense LCRP 2011 #W81XWH-12-1-0286.« less

  1. Investigation of four-dimensional computed tomography-based pulmonary ventilation imaging in patients with emphysematous lung regions

    NASA Astrophysics Data System (ADS)

    Yamamoto, Tokihiro; Kabus, Sven; Klinder, Tobias; Lorenz, Cristian; von Berg, Jens; Blaffert, Thomas; Loo, Billy W., Jr.; Keall, Paul J.

    2011-04-01

    A pulmonary ventilation imaging technique based on four-dimensional (4D) computed tomography (CT) has advantages over existing techniques. However, physiologically accurate 4D-CT ventilation imaging has not been achieved in patients. The purpose of this study was to evaluate 4D-CT ventilation imaging by correlating ventilation with emphysema. Emphysematous lung regions are less ventilated and can be used as surrogates for low ventilation. We tested the hypothesis: 4D-CT ventilation in emphysematous lung regions is significantly lower than in non-emphysematous regions. Four-dimensional CT ventilation images were created for 12 patients with emphysematous lung regions as observed on CT, using a total of four combinations of two deformable image registration (DIR) algorithms: surface-based (DIRsur) and volumetric (DIRvol), and two metrics: Hounsfield unit (HU) change (VHU) and Jacobian determinant of deformation (VJac), yielding four ventilation image sets per patient. Emphysematous lung regions were detected by density masking. We tested our hypothesis using the one-tailed t-test. Visually, different DIR algorithms and metrics yielded spatially variant 4D-CT ventilation images. The mean ventilation values in emphysematous lung regions were consistently lower than in non-emphysematous regions for all the combinations of DIR algorithms and metrics. VHU resulted in statistically significant differences for both DIRsur (0.14 ± 0.14 versus 0.29 ± 0.16, p = 0.01) and DIRvol (0.13 ± 0.13 versus 0.27 ± 0.15, p < 0.01). However, VJac resulted in non-significant differences for both DIRsur (0.15 ± 0.07 versus 0.17 ± 0.08, p = 0.20) and DIRvol (0.17 ± 0.08 versus 0.19 ± 0.09, p = 0.30). This study demonstrated the strong correlation between the HU-based 4D-CT ventilation and emphysema, which indicates the potential for HU-based 4D-CT ventilation imaging to achieve high physiologic accuracy. A further study is needed to confirm these results.

  2. SU-D-17A-04: The Impact of Audiovisual Biofeedback On Image Quality During 4D Functional and Anatomic Imaging: Results of a Prospective Clinical Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keall, P; Pollock, S; Yang, J

    2014-06-01

    Purpose: The ability of audiovisual (AV) biofeedback to improve breathing regularity has not previously been investigated for functional imaging studies. The purpose of this study was to investigate the impact of AV biofeedback on 4D-PET and 4D-CT image quality in a prospective clinical trial. We hypothesized that motion blurring in 4D-PET images and the number of artifacts in 4D-CT images are reduced using AV biofeedback. Methods: AV biofeedback is a real-time, interactive and personalized system designed to help a patient self-regulate his/her breathing using a patient-specific representative waveform and musical guides. In an IRB-approved prospective clinical trial, 4D-PET and 4D-CTmore » images of 10 lung cancer patients were acquired with AV biofeedback (AV) and free breathing (FB). The 4D-PET images in 6 respiratory bins were analyzed for motion blurring by: (1) decrease of GTVPET and (2) increase of SUVmax in 4-DPET compared to 3D-PET. The 4D-CT images were analyzed for artifacts by: (1) comparing normalized cross correlation-based scores (NCCS); and (2) quantifying a visual assessment score (VAS). A two-tailed paired t-test was used to test the hypotheses. Results: The impact of AV biofeedback on 4D-PET and 4D-CT images varied widely between patients, suggesting inconsistent patient comprehension and capability. Overall, the 4D-PET decrease of GTVPET was 2.0±3.0cm3 with AV and 2.3±3.9cm{sup 3} for FB (p=0.61). The 4D-PET increase of SUVmax was 1.6±1.0 with AV and 1.1±0.8 with FB (p=0.002). The 4D-CT NCCS were 0.65±0.27 with AV and 0.60±0.32 for FB (p=0.32). The 4D-CT VAS was 0.0±2.7 (p=ns). Conclusion: A 10-patient study demonstrated a statistically significant reduction of motion blurring of AV over FB for 1/2 functional 4D-PET imaging metrics. No difference between AV and FB was found for 2 anatomic 4D-CT imaging metrics. Future studies will focus on optimizing the human-computer interface and including patient training sessions for improved comprehension and capability. Supported by NIH/NCI R01 CA 093626, Stanford BioX Interdisciplinary Initiatives Program, NHMRC Australia Fellowship, and Kwanjeong Educational Foundation. GE Healthcare provided the Respiratory Gating Toolbox for 4D-PET image reconstruction. Stanford University owns US patent #E7955270 which is unlicensed to any commercial entity.« less

  3. SU-D-201-07: Exploring the Utility of 4D FDG-PET/CT Scans in Design of Radiation Therapy Planning Compared with 3D PET/CT: A Prospective Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, C; Yin, Y

    2015-06-15

    Purpose: A method using four-dimensional(4D) PET/CT in design of radiation treatment planning was proposed and the target volume and radiation dose distribution changes relative to standard three-dimensional (3D) PET/CT were examined. Methods: A target deformable registration method was used by which the whole patient’s respiration process was considered and the effect of respiration motion was minimized when designing radiotherapy planning. The gross tumor volume of a non-small-cell lung cancer was contoured on the 4D FDG-PET/CT and 3D PET/CT scans by use of two different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; another technique using amore » constant threshold of standardized uptake value (SUV) greater than 2.5. The target volume and radiotherapy dose distribution between VOL3D and VOL4D were analyzed. Results: For all phases, the average automatic and manually GTV volume was 18.61 cm3 (range, 16.39–22.03 cm3) and 31.29 cm3 (range, 30.11–35.55 cm3), respectively. The automatic and manually volume of merged IGTV were 27.82 cm3 and 49.37 cm3, respectively. For the manual contour, compared to 3D plan the mean dose for the left, right, and total lung of 4D plan have an average decrease 21.55%, 15.17% and 15.86%, respectively. The maximum dose of spinal cord has an average decrease 2.35%. For the automatic contour, the mean dose for the left, right, and total lung have an average decrease 23.48%, 16.84% and 17.44%, respectively. The maximum dose of spinal cord has an average decrease 1.68%. Conclusion: In comparison to 3D PET/CT, 4D PET/CT may better define the extent of moving tumors and reduce the contouring tumor volume thereby optimize radiation treatment planning for lung tumors.« less

  4. A 4D global respiratory motion model of the thorax based on CT images: A proof of concept.

    PubMed

    Fayad, Hadi; Gilles, Marlene; Pan, Tinsu; Visvikis, Dimitris

    2018-05-17

    Respiratory motion reduces the sensitivity and specificity of medical images especially in the thoracic and abdominal areas. It may affect applications such as cancer diagnostic imaging and/or radiation therapy (RT). Solutions to this issue include modeling of the respiratory motion in order to optimize both diagnostic and therapeutic protocols. Personalized motion modeling required patient-specific four-dimensional (4D) imaging which in the case of 4D computed tomography (4D CT) acquisition is associated with an increased dose. The goal of this work was to develop a global respiratory motion model capable of relating external patient surface motion to internal structure motion without the need for a patient-specific 4D CT acquisition. The proposed global model is based on principal component analysis and can be adjusted to a given patient anatomy using only one or two static CT images in conjunction with a respiratory synchronized patient external surface motion. It is based on the relation between the internal motion described using deformation fields obtained by registering 4D CT images and patient surface maps obtained either from optical imaging devices or extracted from CT image-based patient skin segmentation. 4D CT images of six patients were used to generate the global motion model which was validated by adapting it on four different patients having skin segmented surfaces and two other patients having time of flight camera acquired surfaces. The reproducibility of the proposed model was also assessed on two patients with two 4D CT series acquired within 2 weeks of each other. Profile comparison shows the efficacy of the global respiratory motion model and an improvement while using two CT images in order to adapt the model. This was confirmed by the correlation coefficient with a mean correlation of 0.9 and 0.95 while using one or two CT images respectively and when comparing acquired to model generated 4D CT images. For the four patients with segmented surfaces, expert validation indicates an error of 2.35 ± 0.26 mm compared to 6.07 ± 0.76 mm when using a simple interpolation between full inspiration (FI) and full expiration (FE) CT only; i.e., without specific modeling of the respiratory motion. For the two patients with acquired surfaces, this error was of 2.48 ± 0.18 mm. In terms of reproducibility, model error changes of 0.12 and 0.17 mm were measured for the two patients concerned. The framework for the derivation of a global respiratory motion model was developed. A single or two static CT images and associated patient surface motion, as a surrogate measure, are only needed to personalize the model. This model accuracy and reproducibility were assessed by comparing acquired vs model generated 4D CT images. Future work will consist of assessing extensively the proposed model for radiotherapy applications. © 2018 American Association of Physicists in Medicine.

  5. 4D CT sorting based on patient internal anatomy

    NASA Astrophysics Data System (ADS)

    Li, Ruijiang; Lewis, John H.; Cerviño, Laura I.; Jiang, Steve B.

    2009-08-01

    Respiratory motion during free-breathing computed tomography (CT) scan may cause significant errors in target definition for tumors in the thorax and upper abdomen. A four-dimensional (4D) CT technique has been widely used for treatment simulation of thoracic and abdominal cancer radiotherapy. The current 4D CT techniques require retrospective sorting of the reconstructed CT slices oversampled at the same couch position. Most sorting methods depend on external surrogates of respiratory motion recorded by extra instruments. However, respiratory signals obtained from these external surrogates may not always accurately represent the internal target motion, especially when irregular breathing patterns occur. We have proposed a new sorting method based on multiple internal anatomical features for multi-slice CT scan acquired in the cine mode. Four features are analyzed in this study, including the air content, lung area, lung density and body area. We use a measure called spatial coherence to select the optimal internal feature at each couch position and to generate the respiratory signals for 4D CT sorting. The proposed method has been evaluated for ten cancer patients (eight with thoracic cancer and two with abdominal cancer). For nine patients, the respiratory signals generated from the combined internal features are well correlated to those from external surrogates recorded by the real-time position management (RPM) system (average correlation: 0.95 ± 0.02), which is better than any individual internal measures at 95% confidence level. For these nine patients, the 4D CT images sorted by the combined internal features are almost identical to those sorted by the RPM signal. For one patient with an irregular breathing pattern, the respiratory signals given by the combined internal features do not correlate well with those from RPM (correlation: 0.68 ± 0.42). In this case, the 4D CT image sorted by our method presents fewer artifacts than that from the RPM signal. Our 4D CT internal sorting method eliminates the need of externally recorded surrogates of respiratory motion. It is an automatic, accurate, robust, cost efficient and yet simple method and therefore can be readily implemented in clinical settings.

  6. Providing Social Support for Underrepresented Racial and Ethnic Minority PhD Students in the Biomedical Sciences: A Career Coaching Model

    PubMed Central

    Williams, Simon N.; Thakore, Bhoomi K.; McGee, Richard

    2017-01-01

    Improvement in the proportion of underrepresented racial and ethnic minorities (URMs) in academic positions has been unsatisfactory. Although this is a complex problem, one key issue is that graduate students often rely on research mentors for career-related support, the effectiveness of which can be variable. We present results from a novel academic career “coaching” intervention, one aim of which was to provide supplementary social support for PhD students, particularly those from underrepresented backgrounds. Coaching was delivered both within small groups and on an individual basis, with a diverse group of coaches and students coming from many universities. Coaches were provided with additional diversity training. Ninety-six semistructured interviews with 33 URM students over 3 years were analyzed using a qualitative framework approach. For most of the URM PhD students, coaching provided social support in the form of emotional, informational, and appraisal support. Coaching groups provided a noncompetitive environment and “community of support” within which students were able to learn from one another’s experiences and discuss negative and stressful experiences related to their graduate school, lab, or career plans. This coached peer group model is capable of providing the social support that many URM students do not find at their home universities. PMID:29196425

  7. Can MRI-only replace MRI-CT planning with a titanium tandem and ovoid applicator?

    PubMed

    Harkenrider, Matthew M; Patel, Rakesh; Surucu, Murat; Chinsky, Bonnie; Mysz, Michael L; Wood, Abbie; Ryan, Kelly; Shea, Steven M; Small, William; Roeske, John C

    2018-06-23

    To evaluate dosimetric differences between MRI-only and MRI-CT planning with a titanium tandem and ovoid applicator to determine if all imaging and planning goals can be achieved with MRI only. We evaluated 10 patients who underwent MRI-CT-based cervical brachytherapy with a titanium tandem and ovoid applicator. High-risk clinical target volume and organs at risk were contoured on the 3D T2 MRI, which were transferred to the co-registered CT, where the applicator was identified. Retrospectively, three planners independently delineated the applicator on the axial 3D T2 MRI while blinded to the CT. Identical dwell position times in the delivered plan were loaded. Dose-volume histogram parameters were compared to the previously delivered MRI-CT plan. There were no significant differences in dose to D 90 or D 98 of the high-risk clinical target volume with MRI vs. MRI-CT planning. MRI vs. MRI-CT planning resulted in mean D 0.1cc bladder of 8.8 ± 3.4 Gy vs. 8.5 ± 3.2 Gy (p = 0.29) and D 2cc bladder of 6.2 ± 1.4 Gy vs. 6.0 ± 1.4 Gy (p = 0.33), respectively. Mean D 0.1cc rectum was 5.7 ± 1.2 Gy vs. 5.3 ± 1.2 Gy (p = 0.03) and D 2cc rectum 4.0 ± 0.8 Gy vs. 4.2 ± 1.0 Gy (p = 0.18), respectively. Mean D 0.1cc sigmoid was 5.2 ± 1.3 Gy vs. 5.4 ± 1.6 Gy (p = 0.23) and D 2cc sigmoid 3.9 ± 1.0 Gy vs. 4.0 ± 1.1 Gy (p = 0.18), respectively. There were no clinically significant dosimetric differences between the MRI and MRI-CT plans. This study demonstrates that cervical brachytherapy with a titanium applicator can be planned with MRI alone, which is now our clinical standard. Copyright © 2018. Published by Elsevier Inc.

  8. An algorithm for 4D CT image sorting using spatial continuity.

    PubMed

    Li, Chen; Liu, Jie

    2013-01-01

    4D CT, which could locate the position of the movement of the tumor in the entire respiratory cycle and reduce image artifacts effectively, has been widely used in making radiation therapy of tumors. The current 4D CT methods required external surrogates of respiratory motion obtained from extra instruments. However, respiratory signals recorded by these external makers may not always accurately represent the internal tumor and organ movements, especially when irregular breathing patterns happened. In this paper we have proposed a novel automatic 4D CT sorting algorithm that performs without these external surrogates. The sorting algorithm requires collecting the image data with a cine scan protocol. Beginning with the first couch position, images from the adjacent couch position are selected out according to spatial continuity. The process is continued until images from all couch positions are sorted and the entire 3D volume is produced. The algorithm is verified by respiratory phantom image data and clinical image data. The primary test results show that the 4D CT images created by our algorithm have eliminated the motion artifacts effectively and clearly demonstrated the movement of tumor and organ in the breath period.

  9. Reducing 4D CT artifacts using optimized sorting based on anatomic similarity.

    PubMed

    Johnston, Eric; Diehn, Maximilian; Murphy, James D; Loo, Billy W; Maxim, Peter G

    2011-05-01

    Four-dimensional (4D) computed tomography (CT) has been widely used as a tool to characterize respiratory motion in radiotherapy. The two most commonly used 4D CT algorithms sort images by the associated respiratory phase or displacement into a predefined number of bins, and are prone to image artifacts at transitions between bed positions. The purpose of this work is to demonstrate a method of reducing motion artifacts in 4D CT by incorporating anatomic similarity into phase or displacement based sorting protocols. Ten patient datasets were retrospectively sorted using both the displacement and phase based sorting algorithms. Conventional sorting methods allow selection of only the nearest-neighbor image in time or displacement within each bin. In our method, for each bed position either the displacement or the phase defines the center of a bin range about which several candidate images are selected. The two dimensional correlation coefficients between slices bordering the interface between adjacent couch positions are then calculated for all candidate pairings. Two slices have a high correlation if they are anatomically similar. Candidates from each bin are then selected to maximize the slice correlation over the entire data set using the Dijkstra's shortest path algorithm. To assess the reduction of artifacts, two thoracic radiation oncologists independently compared the resorted 4D datasets pairwise with conventionally sorted datasets, blinded to the sorting method, to choose which had the least motion artifacts. Agreement between reviewers was evaluated using the weighted kappa score. Anatomically based image selection resulted in 4D CT datasets with significantly reduced motion artifacts with both displacement (P = 0.0063) and phase sorting (P = 0.00022). There was good agreement between the two reviewers, with complete agreement 34 times and complete disagreement 6 times. Optimized sorting using anatomic similarity significantly reduces 4D CT motion artifacts compared to conventional phase or displacement based sorting. This improved sorting algorithm is a straightforward extension of the two most common 4D CT sorting algorithms.

  10. SU-F-J-224: Impact of 4D PET/CT On PERCIST Classification of Lung and Liver Metastases in NSLC and Colorectal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meier, J; Lopez, B; Mawlawi, O

    2016-06-15

    Purpose: To quantify the impact of 4D PET/CT on PERCIST metrics in lung and liver tumors in NSCLC and colorectal cancer patients. Methods: 32 patients presenting lung or liver tumors of 1–3 cm size affected by respiratory motion were scanned on a GE Discovery 690 PET/CT. The bed position with lesion(s) affected by motion was acquired in a 12 minute PET LIST mode and unlisted into 8 bins with respiratory gating. Three different CT maps were used for attenuation correction: a clinical helical CT (CT-clin), an average CT (CT-ave), and an 8-phase 4D CINE CT (CT-cine). All reconstructions were 3Dmore » OSEM, 2 iterations, 24 subsets, 6.4 Gaussian filtration, 192×192 matrix, non-TOF, and non-PSF. Reconstructions using CT-clin and CT-ave used only 3 out of the 12 minutes of the data (clinical protocol); all 12 minutes were used for the CT-cine reconstruction. The percent change of SUVbw-peak and SUVbw-max was calculated between PET-CTclin and PET-CTave. The same percent change was also calculated between PET-CTclin and PET-CTcine in each of the 8 bins and in the average of all bins. A 30% difference from PET-CTclin classified lesions as progressive metabolic disease (PMD) using maximum bin value and the average of eight bin values. Results: 30 lesions in 25 patients were evaluated. Using the bin with maximum SUVbw-peak and SUVbw-max difference, 4 and 13 lesions were classified as PMD, respectively. Using the average bin values for SUVbw-peak and SUVbw-max, 3 and 6 lesions were classified as PMD, respectively. Using PET-CTave values for SUVbw-peak and SUVbw-max, 4 and 3 lesions were classified as PMD, respectively. Conclusion: These results suggest that response evaluation in 4D PET/CT is dependent on SUV measurement (SUVpeak vs. SUVmax), number of bins (single or average), and the CT map used for attenuation correction.« less

  11. Calcutta metro: is it safe from noise pollution hazards?

    PubMed

    Bhattacharya, S K; Bandyopadhyay, P; Kashyap, S K

    1996-01-01

    A modest assessment of noise was made in Calcutta Metro, India's first ever underground tube rail system, to examine if the range of noise levels present could endanger the hearing sensitivity of workers for the Metro. Sound measuring instruments of a sound level meter, an octave band analyzer, and a sound level calibrator were used for measuring the sound pressure levels in platforms of three stations: Esplanade, Kalighat and Tollygunge. The results indicated that the averaged A-weighted SPLs in these stations were in the range of 84-87 dBA. In the coaches of the moving train the Leq values ranged 92-99 dBA and LNP 105-117 dBA, all exceeding the safe limit of day time noise exposure of 55 dBA and 85 dBA of ACGIH. The SPLs at 4,000 Hz in the coaches were also in excess of safe exposure limit of 79 dB. The findings thus posed a potential threat to the workers.

  12. [Effects of a coaching program on comprehensive lifestyle modification for women with gestational diabetes mellitus].

    PubMed

    Ko, Jung Mi; Lee, Jong Kyung

    2014-12-01

    The purpose of this study was to investigate the effects of using a Coaching Program on Comprehensive Lifestyle Modification with pregnant women who have gestational diabetes. The research design for this study was a non-equivalent control group quasi-experimental study. Pregnant women with gestational diabetes were recruited from D women's hospital located in Gyeonggi Province from April to October, 2013. Participants in this study were 34 for the control group and 34 for the experimental group. The experimental group participated in the Coaching Program on Comprehensive Lifestyle Modification. The program consisted of education, small group coaching and telephone coaching over 4weeks. Statistical analysis was performed using the SPSS 21.0 program. There were significant improvements in self-care behavior, and decreases in depression, fasting blood sugar and HbA1C in the experimental group compared to the control group. However, no significant differences were found between the two groups for knowledge of gestational diabetes mellitus. The Coaching Program on Comprehensive Lifestyle Modification used in this study was found to be effective in improving self-care behavior and reducing depression, fasting blood sugar and HbA1C, and is recommended for use in clinical practice as an effective nursing intervention for pregnant women with gestational diabetes.

  13. Reducing Head CT Use for Children With Head Injuries in a Community Emergency Department.

    PubMed

    Jennings, Rebecca M; Burtner, Jennifer J; Pellicer, Joseph F; Nair, Deepthi K; Bradford, Miranda C; Shaffer, Michele; Uspal, Neil G; Tieder, Joel S

    2017-04-01

    Clinical decision rules have reduced use of computed tomography (CT) to evaluate minor pediatric head injury in pediatric emergency departments (EDs). CT use remains high in community EDs, where the majority of children seek medical care. We sought to reduce the rate of CT scans used to evaluate pediatric head injury from 29% to 20% in a community ED. We evaluated a quality improvement (QI) project in a community ED aimed at decreasing the use of head CT scans in children by implementing a validated head trauma prediction rule for traumatic brain injury. A multidisciplinary team identified key drivers of CT use and implemented decision aids to improve the use of prediction rules. The team identified and mitigated barriers. An affiliated children's hospital offered Maintenance of Certification credit and QI coaching to participants. We used statistical process control charts to evaluate the effect of the intervention on monthly CT scan rates and performed a Wald test of equivalence to compare preintervention and postintervention CT scan proportions. The baseline period (February 2013-July 2014) included 695 patients with a CT scan rate of 29.2% (95% confidence interval, 25.8%-32.6%). The postintervention period (August 2014-October 2015) included 651 patients with a CT scan rate of 17.4% (95% confidence interval, 14.5%-20.2%, P < .01). Barriers included targeting providers with variable pediatric experience and parental imaging expectations. We demonstrate that a Maintenance of Certification QI project sponsored by a children's hospital can facilitate evidence-based pediatric care and decrease the rate of unnecessary CT use in a community setting. Copyright © 2017 by the American Academy of Pediatrics.

  14. Patient Engagement and Coaching for Health: The PEACH study--a cluster randomised controlled trial using the telephone to coach people with type 2 diabetes to engage with their GPs to improve diabetes care: a study protocol.

    PubMed

    Young, Doris; Furler, John; Vale, Margarite; Walker, Christine; Segal, Leonie; Dunning, Patricia; Best, James; Blackberry, Irene; Audehm, Ralph; Sulaiman, Nabil; Dunbar, James; Chondros, Patty

    2007-04-11

    The PEACH study is based on an innovative 'telephone coaching' program that has been used effectively in a post cardiac event trial. This intervention will be tested in a General Practice setting in a pragmatic trial using existing Practice Nurses (PN) as coaches for people with type 2 diabetes (T2D). Actual clinical care often fails to achieve standards, that are based on evidence that self-management interventions (educational and psychological) and intensive pharmacotherapy improve diabetes control. Telephone coaching in our study focuses on both. This paper describes our study protocol, which aims to test whether goal focused telephone coaching in T2D can improve diabetes control and reduce the treatment gap between guideline based standards and actual clinical practice. In a cluster randomised controlled trial, general practices employing Practice Nurses (PNs) are randomly allocated to an intervention or control group. We aim to recruit 546 patients with poorly controlled T2D (HbA1c >7.5%) from 42 General Practices that employ PNs in Melbourne, Australia. PNs from General Practices allocated to the intervention group will be trained in diabetes telephone coaching focusing on biochemical targets addressing both patient self-management and engaging patients to work with their General Practitioners (GPs) to intensify pharmacological treatment according to the study clinical protocol. Patients of intervention group practices will receive 8 telephone coaching sessions and one face-to-face coaching session from existing PNs over 18 months plus usual care and outcomes will be compared to the control group, who will only receive only usual care from their GPs. The primary outcome is HbA1c levels and secondary outcomes include cardiovascular disease risk factors, behavioral risk factors and process of care measures. Understanding how to achieve comprehensive treatment of T2D in a General Practice setting is the focus of the PEACH study. This study explores the potential role for PNs to help reduce the treatment and outcomes gap in people with T2D by using telephone coaching. The intervention, if found to be effective, has potential to be sustained and embedded within real world General Practice.

  15. Multi-organ segmentation from multi-phase abdominal CT via 4D graphs using enhancement, shape and location optimization.

    PubMed

    Linguraru, Marius George; Pura, John A; Chowdhury, Ananda S; Summers, Ronald M

    2010-01-01

    The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis (CAD) applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D erosion using population historic information of contrast-enhanced liver, spleen, and kidneys was applied to multi-phase data to initialize the 4D graph and adapt to patient specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance and enhancement, and shape and location on organ segmentation.

  16. Implementation of a Personalized, Cost-Effective Physical Therapy Approach (Coach2Move) for Older Adults: Barriers and Facilitators.

    PubMed

    van de Sant, Arjan J W; de Vries, Nienke M; Hoogeboom, Thomas J; Nijhuis-van der Sanden, Maria W G

    2017-07-27

    This article reports on a recent randomized clinical trial that showed a personalized approach to physical therapy (Coach2Move) by a physical therapist specialized in geriatrics (PTG) to be more cost-effective than usual physical therapy care in people with mobility problems (n = 130, mean age = 78 years). We used an explanatory mixed-methods sequential design alongside the randomized clinical trial to gain insight into (a) the contrast between the 2 interventions, (b) the fidelity of the Coach2Move delivery; (c) PTGs' experiences of Coach2Move; and (d) possible barriers and facilitators for future implementation. The study included 13 PTGs educated in the strategy and 13 physical therapists with expertise in geriatrics delivering the usual care. In total, 106 medical records were available for assessment: 57 (85%) Coach2Move, 49 (75%) usual care. Quantitative process indicators were used to analyze electronic medical records to determine contrasts in the phases of clinical reasoning. The fidelity of the delivery was tested using indicator scores focusing on 4 key elements of Coach2Move. In-depth interviews with Coach2Move therapists were thematically analyzed to explore experiences and facilitators/barriers related to implementation. Indicator scores showed significant and clinically relevant contrasts in all phases of clinical reasoning, with consistently higher scores among PTGs, except for the treatment plan. Moreover, the fidelity of Coach2Move delivery was more than 70% in all phases, except the evaluation phase (53%). Experiences of Coach2Move were positive. In particular, extended intake allowing motivational interviewing, physical examination and an in-depth problem analysis, and shared goal setting were considered valuable. Facilitators for implementation were the addition of a Coach2Move medical record, frequent coaching by the researcher, and readiness to change in the therapist. Barriers were (1) having to use 2 parallel electronic medical record systems, (2) having to clear the calendar to schedule an intake of 90 minutes, (3) fear of losing income, (4) the sense that patients do not want to change their lifestyle, and (5) not acknowledging that increasing physical activity is an important goal for older adults with mobility problems. Physical therapy based on the Coach2Move strategy is substantially different from usual care. Future implementation should focus on increasing regular evaluation and feedback, taking into account individuals' contextual factors, and improving organizational facilities while mitigating income loss.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  17. Adaptation of the Grasha Riechman Student Learning Style Survey and Teaching Style Inventory to assess individual teaching and learning styles in a quality improvement collaborative.

    PubMed

    Ford, James H; Robinson, James M; Wise, Meg E

    2016-09-29

    NIATx200, a quality improvement collaborative, involved 201 substance abuse clinics. Each clinic was randomized to one of four implementation strategies: (a) interest circle calls, (b) learning sessions, (c) coach only or (d) a combination of all three. Each strategy was led by NIATx200 coaches who provided direct coaching or facilitated the interest circle and learning session interventions. Eligibility was limited to NIATx200 coaches (N = 18), and the executive sponsor/change leader of participating clinics (N = 389). Participants were invited to complete a modified Grasha Riechmann Student Learning Style Survey and Teaching Style Inventory. Principal components analysis determined participants' preferred learning and teaching styles. Responses were received from 17 (94.4 %) of the coaches. Seventy-two individuals were excluded from the initial sample of change leaders and executive sponsors (N = 389). Responses were received from 80 persons (25.2 %) of the contactable individuals. Six learning profiles for the executive sponsors and change leaders were identified: Collaborative/Competitive (N = 28, 36.4 %); Collaborative/Participatory (N = 19, 24.7 %); Collaborative only (N = 17, 22.1 %); Collaborative/Dependent (N = 6, 7.8 %); Independent (N = 3, 5.2 %); and Avoidant/Dependent (N = 3, 3.9 %). NIATx200 coaches relied primarily on one of four coaching profiles: Facilitator (N = 7, 41.2 %), Facilitator/Delegator (N = 6, 35.3 %), Facilitator/Personal Model (N = 3, 17.6 %) and Delegator (N = 1, 5.9 %). Coaches also supported their primary coaching profiles with one of eight different secondary coaching profiles. The study is one of the first to assess teaching and learning styles within a QIC. Results indicate that individual learners (change leaders and executive sponsors) and coaches utilize multiple approaches in the teaching and practice-based learning of quality improvement (QI) processes. Identification teaching profiles could be used to tailor the collaborative structure and content delivery. Efforts to accommodate learning styles would facilitate knowledge acquisition enhancing the effectiveness of a QI collaborative to improve organizational processes and outcomes. ClinicalTrials.gov Identifier: NCT00934141 Registered July 6, 2009. Retrospectively registered.

  18. Respiratory motion-resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK): Initial clinical experience on an MRI-guided radiotherapy system.

    PubMed

    Han, Fei; Zhou, Ziwu; Du, Dongsu; Gao, Yu; Rashid, Shams; Cao, Minsong; Shaverdian, Narek; Hegde, John V; Steinberg, Michael; Lee, Percy; Raldow, Ann; Low, Daniel A; Sheng, Ke; Yang, Yingli; Hu, Peng

    2018-06-01

    To optimize and evaluate the respiratory motion-resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK-4D-MRI) method in a 0.35 T MRI-guided radiotherapy (MRgRT) system. The study included seven patients with abdominal tumors treated on the MRgRT system. ROCK-4D-MRI and 2D-CINE, was performed immediately after one of the treatment fractions. Motion quantification based on 4D-MRI was compared with those based on 2D-CINE. The image quality of 4D-MRI was evaluated against 4D-CT. The gross tumor volumes (GTV) were defined based on individual respiratory phases of both 4D-MRI and 4D-CT and compared for their variability over the respiratory cycle. The motion measurements based on 4D-MRI matched well with 2D-CINE, with differences of 1.04 ± 0.52 mm in the superior-inferior and 0.54 ± 0.21 mm in the anterior-posterior directions. The image quality scores of 4D-MRI were significantly higher than 4D-CT, with better tumor contrast (3.29 ± 0.76 vs. 1.86 ± 0.90) and less motion artifacts (3.57 ± 0.53 vs. 2.29 ± 0.95). The GTVs were more consistent in 4D-MRI than in 4D-CT, with significantly smaller GTV variability (9.31 ± 4.58% vs. 34.27 ± 23.33%). Our study demonstrated the clinical feasibility of using the ROCK-4D-MRI to acquire high quality, respiratory motion-resolved 4D-MRI in a low-field MRgRT system. The 4D-MRI image could provide accurate dynamic information for radiotherapy treatment planning. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. TU-F-17A-08: The Relative Accuracy of 4D Dose Accumulation for Lung Radiotherapy Using Rigid Dose Projection Versus Dose Recalculation On Every Breathing Phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamb, J; Lee, C; Tee, S

    2014-06-15

    Purpose: To investigate the accuracy of 4D dose accumulation using projection of dose calculated on the end-exhalation, mid-ventilation, or average intensity breathing phase CT scan, versus dose accumulation performed using full Monte Carlo dose recalculation on every breathing phase. Methods: Radiotherapy plans were analyzed for 10 patients with stage I-II lung cancer planned using 4D-CT. SBRT plans were optimized using the dose calculated by a commercially-available Monte Carlo algorithm on the end-exhalation 4D-CT phase. 4D dose accumulations using deformable registration were performed with a commercially available tool that projected the planned dose onto every breathing phase without recalculation, as wellmore » as with a Monte Carlo recalculation of the dose on all breathing phases. The 3D planned dose (3D-EX), the 3D dose calculated on the average intensity image (3D-AVE), and the 4D accumulations of the dose calculated on the end-exhalation phase CT (4D-PR-EX), the mid-ventilation phase CT (4D-PR-MID), and the average intensity image (4D-PR-AVE), respectively, were compared against the accumulation of the Monte Carlo dose recalculated on every phase. Plan evaluation metrics relating to target volumes and critical structures relevant for lung SBRT were analyzed. Results: Plan evaluation metrics tabulated using 4D-PR-EX, 4D-PR-MID, and 4D-PR-AVE differed from those tabulated using Monte Carlo recalculation on every phase by an average of 0.14±0.70 Gy, - 0.11±0.51 Gy, and 0.00±0.62 Gy, respectively. Deviations of between 8 and 13 Gy were observed between the 4D-MC calculations and both 3D methods for the proximal bronchial trees of 3 patients. Conclusions: 4D dose accumulation using projection without re-calculation may be sufficiently accurate compared to 4D dose accumulated from Monte Carlo recalculation on every phase, depending on institutional protocols. Use of 4D dose accumulation should be considered when evaluating normal tissue complication probabilities as well as in clinical situations where target volumes are directly inferior to mobile critical structures.« less

  20. Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

    PubMed Central

    Lee, Tzu-Cheng; Alessio, Adam M.; Wollenweber, Scott D.; Stearns, Charles W.; Bowen, Stephen R.; Kinahan, Paul E.

    2015-01-01

    Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUVmax, SUVmean, SUVpeak, and segmented tumor volume was evaluated as RCmax, RCmean, RCpeak, and RCvol, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RCmax, RCpeak, RCmean, and RCvol. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RCmax, RCpeak, RCmean, and RCvol. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by the patient-specific respiratory waveforms; when testing patient and sinusoidal waveforms separately, patient waveforms were significantly different between phases (p < 0.0001) while the sinusoidal waveforms were not significantly different (p = 0.98). When considering only the subset of 4DMATCH images that corresponded to the end-exhale image phase, 4DEXH, mean and interquartile range were similar to 4DMATCH but variability was considerably reduced. Conclusions: Comparative advantages in accuracy and precision of SUV metrics and segmented volumes were demonstrated with the use of the maximum intensity projection and end-exhale CT attenuation correction. While respiratory phase-matched CTAC should in theory provide optimal corrections, image artifacts and differences in implementation of 4DCT and 4DPET sorting can degrade the benefit of this approach. These results may be useful to guide the implementation, analysis, and development of respiratory-correlated thoracic PET/CT in the radiation oncology and diagnostic settings. PMID:25563252

  1. Intraoperative assessment of reduction and implant placement in acetabular fractures-limitations of 3D-imaging compared to computed tomography.

    PubMed

    Keil, Holger; Beisemann, Nils; Schnetzke, Marc; Vetter, Sven Yves; Swartman, Benedict; Grützner, Paul Alfred; Franke, Jochen

    2018-04-10

    In acetabular fractures, the assessment of reduction and implant placement has limitations in conventional 2D intraoperative imaging. 3D imaging offers the opportunity to acquire CT-like images and thus to improve the results. However, clinical experience shows that even 3D imaging has limitations, especially regarding artifacts when implants are placed. The purpose of this study was to assess the difference between intraoperative 3D imaging and postoperative CT regarding reduction and implant placement. Twenty consecutive cases of acetabular fractures were selected with a complete set of intraoperative 3D imaging and postoperative CT data. The largest detectable step and the largest detectable gap were measured in all three standard planes. These values were compared between the 3D data sets and CT data sets. Additionally, possible correlations between the possible confounders age and BMI and the difference between 3D and CT values were tested. The mean difference of largest visible step between the 3D imaging and CT scan was 2.0 ± 1.8 mm (0.0-5.8, p = 0.02) in the axial, 1.3 ± 1.4 mm (0.0-3.7, p = 0.15) in the sagittal and 1.9 ± 2.4 mm (0.0-7.4, p = 0.22) in the coronal views. The mean difference of largest visible gap between the 3D imaging and CT scan was 3.1 ± 3.6 mm (0.0-14.1, p = 0.03) in the axial, 4.6 ± 2.7 mm (1.2-8.7, p = 0.001) in the sagittal and 3.5 ± 4.0 mm (0.0-15.4, p = 0.06) in the coronal views. A positive correlation between the age and the difference in gap measurements in the sagittal view was shown (rho = 0.556, p = 0.011). Intraoperative 3D imaging is a valuable adjunct in assessing reduction and implant placement in acetabular fractures but has limitations due to artifacts caused by implant material. This can lead to missed malreduction and impairment of clinical outcome, so postoperative CT should be considered in these cases.

  2. Four-Dimensional Magnetic Resonance Imaging Using Axial Body Area as Respiratory Surrogate: Initial Patient Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Juan; School of Information Science and Engineering, Shandong University, Jinan, Shandong; Cai, Jing

    Purpose: To evaluate the feasibility of a retrospective binning technique for 4-dimensional magnetic resonance imaging (4D-MRI) using body area (BA) as a respiratory surrogate. Methods and Materials: Seven patients with hepatocellular carcinoma (4 of 7) or liver metastases (3 of 7) were enrolled in an institutional review board-approved prospective study. All patients were simulated with both computed tomography (CT) and MRI to acquire 3-dimensinal and 4D images for treatment planning. Multiple-slice multiple-phase cine-MR images were acquired in the axial plane for 4D-MRI reconstruction. Image acquisition time per slice was set to 10-15 seconds. Single-slice 2-dimensinal cine-MR images were also acquiredmore » across the center of the tumor in orthogonal planes. Tumor motion trajectories from 4D-MRI, cine-MRI, and 4D-CT were analyzed in the superior–inferior (SI), anterior–posterior (AP), and medial–lateral (ML) directions, respectively. Their correlation coefficients (CC) and differences in tumor motion amplitude were determined. Tumor-to-liver contrast-to-noise ratio (CNR) was measured and compared between 4D-CT, 4D-MRI, and conventional T2-weighted fast spin echo MRI. Results: The means (±standard deviations) of CC comparing 4D-MRI with cine-MRI were 0.97 ± 0.03, 0.97 ± 0.02, and 0.99 ± 0.04 in SI, AP, and ML directions, respectively. The mean differences were 0.61 ± 0.17 mm, 0.32 ± 0.17 mm, and 0.14 ± 0.06 mm in SI, AP, and ML directions, respectively. The means of CC comparing 4D-MRI and 4D-CT were 0.95 ± 0.02, 0.94 ± 0.02, and 0.96 ± 0.02 in SI, AP, and ML directions, respectively. The mean differences were 0.74 ± 0.02 mm, 0.33 ± 0.13 mm, and 0.18 ± 0.07 mm in SI, AP, and ML directions, respectively. The mean tumor-to-tissue CNRs were 2.94 ± 1.51, 19.44 ± 14.63, and 39.47 ± 20.81 in 4D-CT, 4D-MRI, and T2-weighted MRI, respectively. Conclusions: The preliminary evaluation of our 4D-MRI technique results in oncologic patients demonstrates its potential usefulness to accurately measure tumor respiratory motion with improved tumor CNR compared with 4D-CT.« less

  3. Rational Design of Charge-Transfer Interactions in Halogen-Bonded Co-crystals toward Versatile Solid-State Optoelectronics.

    PubMed

    Zhu, Weigang; Zheng, Renhui; Zhen, Yonggang; Yu, Zhenyi; Dong, Huanli; Fu, Hongbing; Shi, Qiang; Hu, Wenping

    2015-09-02

    Charge-transfer (CT) interactions between donor (D) and acceptor (A) groups, as well as CT exciton dynamics, play important roles in optoelectronic devices, such as organic solar cells, photodetectors, and light-emitting sources, which are not yet well understood. In this contribution, the self-assembly behavior, molecular stacking structure, CT interactions, density functional theory (DFT) calculations, and corresponding physicochemical properties of two similar halogen-bonded co-crystals are comprehensively investigated and compared, to construct an "assembly-structure-CT-property" relationship. Bpe-IFB wire-like crystals (where Bpe = 1,2-bis(4-pyridyl)ethylene and IFB = 1,3,5-trifluoro-2,4,6-triiodobenzene), packed in a segregated stacking form with CT ground and excited states, are measured to be quasi-one-dimensional (1D) semiconductors and show strong violet-blue photoluminescence (PL) from the lowest CT1 excitons (ΦPL = 26.1%), which can be confined and propagate oppositely along the 1D axial direction. In comparison, Bpe-F4DIB block-like crystals (F4DIB = 1,4-diiodotetrafluorobenzene), packed in a mixed stacking form without CT interactions, are determined to be insulators and exhibit unique white light emission and two-dimensional optical waveguide property. Surprisingly, it seems that the intrinsic spectroscopic states of Bpe and F4DIB do not change after co-crystallization, which is also confirmed by theoretical calculations, thus offering a new design principle for white light emitting materials. More importantly, we show that the CT interactions in co-crystals are related to their molecular packing and can be triggered or suppressed by crystal engineering, which eventually leads to distinct optoelectronic properties. These results help us to rationally control the CT interactions in organic D-A systems by tuning the molecular stacking, toward the development of a fantastic "optoelectronic world".

  4. WE-H-207A-02: Attenuation Correction in 4D-PET Using a Single-Phase Attenuation Map

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalantari, F; Wang, J

    2016-06-15

    Purpose: 4D-PET imaging has been proposed as a potential solution to the respiratory motion effect in thoracic region. CT-based attenuation correction (AC) is an essential step toward quantitative imaging for PET. However, due to the temporal difference of 4D-PET and a single breath-hold CT, motion artifacts are observed in the attenuation-corrected PET images that can lead to error in tumor shape and uptake. We introduce a practical method for aligning single-phase CT to all other 4D-PET phases using a penalized non-rigid demons registration. Methods: Individual 4D-PET frames were reconstructed without AC. Non-rigid Demons registration was used to derive deformation vectormore » fields (DVFs) between the PET matched with CT phase and other 4D-PET images. While attenuated PET images provide enough useful data for organ borders such as lung and liver, tumors are not distinguishable from background due to loss of contrast. To preserve tumor shape in different phases, from CT image an ROI covering tumor was excluded from non-rigid transformation. Mean DVF of the central region of the tumor was assigned to all voxels in the ROI. This process mimics a rigid transformation of tumor along with a non-rigid transformation of other organs. 4D XCAT phantom with spherical tumors in lung with diameters ranging from 10 to 40 mm was used to evaluate the algorithm. Results: Motion related induced artifacts in attenuation-corrected 4D-PET images were significantly reduced. For tumors smaller than 20 mm, non-rigid transformation was capable to provide quantitative results. However, for larger tumors, where tumor self-attenuation is considerable, our combined method yields superior results. Conclusion: We introduced a practical method for deforming a single CT to match all 4D-PET images for accurate AC. Although 4D-PET data include insignificant anatomical information, we showed that they are still useful to estimate DVFs for aligning attenuation map and accurate AC.« less

  5. Performance tests for ray-scan 64 PET/CT based on NEMA NU-2 2007

    NASA Astrophysics Data System (ADS)

    Li, Suying; Zhou, Kun; Zhang, Qiushi; Zhang, Jinming; Yang, Kun; Xu, Baixuan; Ren, Qiushi

    2015-03-01

    This paper focuses on evaluating the performance of the Ray-Scan 64 PET/CT system, a newly developed PET/CT in China. It combines a 64 slice helical CT scanner with a high resolution PET scanner based on BGO crystals assembled in 36 rings. The energy window is 350~ 650 keV, and the coincidence window is set at 12 ns in both 2D and 3D mode. The transaxial field of view (FOV) is 600 mm in diameter, and the axial FOV is 163 mm. Method: Performance measurements were conducted focusing on PET scanners based on NEMA NU-2 2007 standard. We reported the full characterization (spatial resolution, sensitivity, count rate performance, scatter fraction, accuracy of correction, and image quality) in both 2D and 3D mode. In addition, the clinical images from two patients of different types of tumor were presented to further demonstrate this PET/CT system performance in clinical application. Results: using the NEMA NU-2 2007 standard, the main results: (1) the transaxial resolution at 1cm from the gantry center for 2D and 3D was both 4.5mm (FWHM), and at 10cm from the gantry center, the radial (tangential) resolution were 5.6mm (5.3mm) and 5.4mm (5.2mm) in 2D and 3D mode respectively. The axial resolution at 1cm and 10cm off axis was 3.4mm (4.8mm) and 5.5mm (5.8mm) in 2D (3D) mode respectively; (2) the sensitivity for the radial position R0(r=0mm) and R100(r=100mm) were 1.741 kcps/MBq and 1.767 kcps/MBq respectively in 2D mode and 7.157 kcps/MBq and 7.513 kcps/MBq in 3D mode; (3) the scatter fraction was calculated as 18.36% and 42.92% in 2D and 3D mode, respectively; (4) contrast of hot spheres in the image quality phantom in 2D mode was 50.33% (52.87%), 33.34% (40.86%), 20.64% (26.36%), and 10.99% (15.82%), respectively, in N=4 (N=8). Besides, in clinical study, the diameter of lymph tumor was about 2.4 cm, and the diameter of lung cancer was 4.2 cm. This PET/CT system can distinguish the position of cancer easily. Conclusion: The results show that the performance of the newly developed PET/CT system is of high resolution, and low scatter characteristics, and is suitable for clinical applications.

  6. Improving the Diagnostic Specificity of CT for Early Detection of Lung Cancer: 4D CT-Based Pulmonary Nodule Elastometry

    DTIC Science & Technology

    2015-10-01

    malignant PNs treated with stereotactic ablative radiotherapy ( SABR ) with those of the lung. Methods: We analyzed breath-hold images of 30...patients with malignant PNs who underwent SABR in our department. A parametric nonrigid transformation model based on multi-level B-spline guided by Sum of...and 50 of 4D CT and deep inhale and natural exhale of breath-hold CT images of 30 MPN treated with stereotactic ablative radiotherapy ( SABR ). The

  7. Implications of free breathing motion assessed by 4D-computed tomography on the delivered dose in radiotherapy for esophageal cancer.

    PubMed

    Duma, Marciana Nona; Berndt, Johannes; Rondak, Ina-Christine; Devecka, Michal; Wilkens, Jan J; Geinitz, Hans; Combs, Stephanie Elisabeth; Oechsner, Markus

    2015-01-01

    The aim of this study was to assess the effect of breathing motion on the delivered dose in esophageal cancer 3-dimensional (3D)-conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric modulated arc therapy (VMAT). We assessed 16 patients with esophageal cancer. All patients underwent 4D-computed tomography (4D-CT) for treatment planning. For each of the analyzed patients, 1 3D-CRT, 1 IMRT, and 1 VMAT (RapidArc-RA) plan were calculated. Each of the 3 initial plans was recalculated on the 4D-CT (for the maximum free inspiration and maximum free expiration) to assess the effect of breathing motion. We assessed the minimum dose (Dmin) and mean dose (Dmean) to the esophagus within the planning target volume, the volume changes of the lungs, the Dmean and the total lung volume receiving at least 40Gy (V40), and the V30, V20, V10, and V5. For the heart we assessed the Dmean and the V25. Over all techniques and all patients the change in Dmean as compared with the planned Dmean (planning CT [PCT]) to the esophagus was 0.48% in maximum free inspiration (CT_insp) and 0.55% in maximum free expiration (CT_exp). The Dmin CT_insp change was 0.86% and CT_exp change was 0.89%. The Dmean change of the lungs (heart) was in CT_insp 1.95% (2.89%) and 3.88% (2.38%) in CT_exp. In all, 4 patients had a clinically relevant change of the dose (≥ 5% Dmean to the heart and the lungs) between inspiration and expiration. These patients had a very cranially or caudally situated tumor. There are no relevant differences in the delivered dose to the regions of interest among the 3 techniques. Breathing motion management could be considered to achieve a better sparing of the lungs or heart in patients with cranially or caudally situated tumors. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  8. Dietary Intervention for Glucose Tolerance In Teens (DIG IT): Protocol of a randomized controlled trial using health coaching to prevent youth-onset type 2 diabetes.

    PubMed

    Wagner, Kelly A; Braun, Ethan; Armah, Seth M; Horan, Diarmuid; Smith, Lisa G; Pike, Julie; Tu, Wanzhu; Hamilton, Marc T; Delp, Edward J; Campbell, Wayne W; Boushey, Carol J; Hannon, Tamara S; Gletsu-Miller, Nana

    2017-02-01

    Youth-onset type 2 diabetes (T2D) is a disease that is newly emerging and behavioral strategies for its prevention are limited. Interventions that target the lifestyle behaviors of adolescents, to improve poor dietary quality and reduce excessive sedentariness, promise to reduce the risk of developing T2D. Health coaching is effective for promoting healthy behaviors in patients who have chronic disease, but few experimental studies are in adolescents. This randomized controlled trial, in adolescents with prediabetes, will determine the effectiveness of a health coaching intervention to facilitate adoption of healthy diet and activity behaviors that delay or prevent development of T2D. The Dietary Intervention for Glucose Tolerance In Teens (DIG IT) trial will involve an evaluation of a health coaching intervention in adolescents with prediabetes. Eligible participants will be randomized to receive 6months of health coaching or a single dietary consultation that is standard-of-care. The primary outcome will be 2-hour oral glucose tolerance test concentration. Secondary outcomes will include measures of glycemia and insulin action as well as dietary, physical activity and sedentary behaviors measured using an electronic food record, and by inclinometer. Data will be collected before and after the intervention (at 6months) and at 12months (to assess sustainability). This trial will determine whether a health coaching intervention, a personalized and low-cost approach to modify dietary and activity behaviors, is effective and sustainable for prevention of youth-onset T2D, relative to standard-of-care. Health coaching has the potential to be widely implemented in clinical or community settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Four-Dimensional CT of the Diaphragm in Children: Initial Experience

    PubMed Central

    2018-01-01

    Objective To evaluate the technical feasibility of four-dimensional (4D) CT for the functional evaluation of the pediatric diaphragm. Materials and Methods In 22 consecutive children (median age 3.5 months, age range 3 days–3 years), 4D CT was performed to assess diaphragm motion. Diaphragm abnormalities were qualitatively evaluated and diaphragm motion was quantitatively measured on 4D CT. Lung density changes between peak inspiration and expiration were measured in the basal lung parenchyma. The diaphragm motions and lung density changes measured on 4D CT were compared between various diaphragm conditions. In 11 of the 22 children, chest sonography was available for comparison. Results Four-dimensional CT demonstrated normal diaphragm (n = 8), paralysis (n = 10), eventration (n = 3), and diffusely decreased motion (n = 1). Chest sonography demonstrated normal diaphragm (n = 2), paralysis (n = 6), eventration (n = 2), and right pleural effusion (n = 1). The sonographic findings were concordant with the 4D CT findings in 90.9% (10/11) of the patients. In diaphragm paralysis, the affected diaphragm motion was significantly decreased compared with the contralateral normal diaphragm motion (−1.1 ± 2.2 mm vs. 7.6 ± 3.8 mm, p = 0.005). The normal diaphragms showed significantly greater motion than the paralyzed diaphragms (4.5 ± 2.1 mm vs. −1.1 ± 2.2 mm, p < 0.0001), while the normal diaphragm motion was significantly smaller than the motion of the contralateral normal diaphragm in paralysis (4.5 ± 2.1 mm vs. 7.6 ± 3.8 mm, p = 0.01). Basal lung density change of the affected side was significantly smaller than that of the contralateral side in diaphragm paralysis (89 ± 73 Hounsfield units [HU] vs. 180 ± 71 HU, p = 0.03), while no significant differences were found between the normal diaphragms and the paralyzed diaphragms (136 ± 66 HU vs. 89 ± 73 HU, p = 0.1) or between the normal diaphragms and the contralateral normal diaphragms in paralysis (136 ± 66 HU vs. 180 ± 71 HU, p = 0.1). Conclusion The functional evaluation of the pediatric diaphragm is feasible with 4D CT in select children. PMID:29354007

  10. U.S. EPA, Pesticide Product Label, , 03/20/1975

    EPA Pesticide Factsheets

    2011-04-21

    ... i4 S ~"aula~ Lt;i ... Po ~ct 4rci~ ~~£, tat~~~ ccnd~tic~~ ~av~~ d~{~t !\\r~ 4~~a) :,cat~d. 0: ~ct eO'lt~~i~ar~ ~al ... chemicil descrlntl~" on the la~el dnd '. ...

  11. Catching the Bug: How Virtual Coaching Improves Teaching

    ERIC Educational Resources Information Center

    Allen, Megan

    2014-01-01

    In this article the author describes virtual coaching and why it is so effective. The following six points of virtual coaching are explained: (1) Also known as bug-in-ear coaching, virtual coaching is not new; (2) Virtual coaching can save money and time; (3) Bug-in-ear coaching increases the frequency of observations for novice teachers; (4) It…

  12. Coaching Discourse: Supporting Teachers' Professional Learning

    ERIC Educational Resources Information Center

    Heineke, Sally F.

    2013-01-01

    Although coaching is used in many schools to facilitate teachers' professional learning, few studies look closely at coaching discourse. Exploring how coaching facilitates teachers' professional development, this study used tape-recorded coaching sessions and individual post-interviews to examine the one-on-one coaching interactions of 4…

  13. Impact of coaching certification on coaching attitudes.

    PubMed

    Graham, R H; Carron, A V

    1983-09-01

    The purpose of the present investigation was to examine the impact of coaching certification upon coaching attitudes toward important social psychological correlates of involvement in sport. Specifically, 249 coaches with 0, 1, 2, 3, 4 and 5 levels of certification in the National Coaching Certification Program for Hockey were compared on attitudes toward important social psychological correlates of athletic involvement. As a consequence of anomalies in the sample, the six levels of certification were collapsed to form a factorial design comprising 2 levels of certification (coaches with 0.1 and 2 levels versus coaches with 3, 4, and 5 levels) and 2 levels of competition (house league versus competitive league coaches). The results revealed that coaches with greater certification were older and more experienced. Also, coaches in competitive leagues were more experienced, attached more importance to setting realistic objectives and playing well, but less importance to providing a recreational experience for players than house league coaches. Also, with increasing certification, coaches in competitive leagues attached increased importance to beating an opponent and having a winning team while house league coaches showed a decrease. Finally, the emphasis planed upon providing equal ice time for all players remained low over the two levels of certification in the competitive league coaches; it showed a decrease with greater certification in the house league coaches.

  14. Impact of temporal probability in 4D dose calculation for lung tumors.

    PubMed

    Rouabhi, Ouided; Ma, Mingyu; Bayouth, John; Xia, Junyi

    2015-11-08

    The purpose of this study was to evaluate the dosimetric uncertainty in 4D dose calculation using three temporal probability distributions: uniform distribution, sinusoidal distribution, and patient-specific distribution derived from the patient respiratory trace. Temporal probability, defined as the fraction of time a patient spends in each respiratory amplitude, was evaluated in nine lung cancer patients. Four-dimensional computed tomography (4D CT), along with deformable image registration, was used to compute 4D dose incorporating the patient's respiratory motion. First, the dose of each of 10 phase CTs was computed using the same planning parameters as those used in 3D treatment planning based on the breath-hold CT. Next, deformable image registration was used to deform the dose of each phase CT to the breath-hold CT using the deformation map between the phase CT and the breath-hold CT. Finally, the 4D dose was computed by summing the deformed phase doses using their corresponding temporal probabilities. In this study, 4D dose calculated from the patient-specific temporal probability distribution was used as the ground truth. The dosimetric evaluation matrix included: 1) 3D gamma analysis, 2) mean tumor dose (MTD), 3) mean lung dose (MLD), and 4) lung V20. For seven out of nine patients, both uniform and sinusoidal temporal probability dose distributions were found to have an average gamma passing rate > 95% for both the lung and PTV regions. Compared with 4D dose calculated using the patient respiratory trace, doses using uniform and sinusoidal distribution showed a percentage difference on average of -0.1% ± 0.6% and -0.2% ± 0.4% in MTD, -0.2% ± 1.9% and -0.2% ± 1.3% in MLD, 0.09% ± 2.8% and -0.07% ± 1.8% in lung V20, -0.1% ± 2.0% and 0.08% ± 1.34% in lung V10, 0.47% ± 1.8% and 0.19% ± 1.3% in lung V5, respectively. We concluded that four-dimensional dose computed using either a uniform or sinusoidal temporal probability distribution can approximate four-dimensional dose computed using the patient-specific respiratory trace.

  15. Pulmonary Ventilation Imaging Based on 4-Dimensional Computed Tomography: Comparison With Pulmonary Function Tests and SPECT Ventilation Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Tokihiro, E-mail: toyamamoto@ucdavis.edu; Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California; Kabus, Sven

    Purpose: 4-dimensional computed tomography (4D-CT)-based pulmonary ventilation imaging is an emerging functional imaging modality. The purpose of this study was to investigate the physiological significance of 4D-CT ventilation imaging by comparison with pulmonary function test (PFT) measurements and single-photon emission CT (SPECT) ventilation images, which are the clinical references for global and regional lung function, respectively. Methods and Materials: In an institutional review board–approved prospective clinical trial, 4D-CT imaging and PFT and/or SPECT ventilation imaging were performed in thoracic cancer patients. Regional ventilation (V{sub 4DCT}) was calculated by deformable image registration of 4D-CT images and quantitative analysis for regional volumemore » change. V{sub 4DCT} defect parameters were compared with the PFT measurements (forced expiratory volume in 1 second (FEV{sub 1}; % predicted) and FEV{sub 1}/forced vital capacity (FVC; %). V{sub 4DCT} was also compared with SPECT ventilation (V{sub SPECT}) to (1) test whether V{sub 4DCT} in V{sub SPECT} defect regions is significantly lower than in nondefect regions by using the 2-tailed t test; (2) to quantify the spatial overlap between V{sub 4DCT} and V{sub SPECT} defect regions with Dice similarity coefficient (DSC); and (3) to test ventral-to-dorsal gradients by using the 2-tailed t test. Results: Of 21 patients enrolled in the study, 18 patients for whom 4D-CT and either PFT or SPECT were acquired were included in the analysis. V{sub 4DCT} defect parameters were found to have significant, moderate correlations with PFT measurements. For example, V{sub 4DCT}{sup HU} defect volume increased significantly with decreasing FEV{sub 1}/FVC (R=−0.65, P<.01). V{sub 4DCT} in V{sub SPECT} defect regions was significantly lower than in nondefect regions (mean V{sub 4DCT}{sup HU} 0.049 vs 0.076, P<.01). The average DSCs for the spatial overlap with SPECT ventilation defect regions were only moderate (V{sub 4DCT}{sup HU}0.39 ± 0.11). Furthermore, ventral-to-dorsal gradients of V{sub 4DCT} were strong (V{sub 4DCT}{sup HU} R{sup 2} = 0.69, P=.08), which was similar to V{sub SPECT} (R{sup 2} = 0.96, P<.01). Conclusions: An 18-patient study demonstrated significant correlations between 4D-CT ventilation and PFT measurements as well as SPECT ventilation, providing evidence toward the validation of 4D-CT ventilation imaging.« less

  16. Planning 4D intensity-modulated arc therapy for tumor tracking with a multileaf collimator

    NASA Astrophysics Data System (ADS)

    Niu, Ying; Betzel, Gregory T.; Yang, Xiaocheng; Gui, Minzhi; Parke, William C.; Yi, Byongyong; Yu, Cedric X.

    2017-02-01

    This study introduces a practical four-dimensional (4D) planning scheme of IMAT using 4D computed tomography (4D CT) for planning tumor tracking with dynamic multileaf beam collimation. We assume that patients can breathe regularly, i.e. the same way as during 4D CT with an unchanged period and amplitude, and that the start of 4D-IMAT delivery can be synchronized with a designated respiratory phase. Each control point of the IMAT-delivery process can be associated with an image set of 4D CT at a specified respiratory phase. Target is contoured at each respiratory phase without a motion-induced margin. A 3D-IMAT plan is first optimized on a reference-phase image set of 4D CT. Then, based on the projections of the planning target volume in the beam’s eye view at different respiratory phases, a 4D-IMAT plan is generated by transforming the segments of the optimized 3D plan by using a direct aperture deformation method. Compensation for both translational and deformable tumor motion is accomplished, and the smooth delivery of the transformed plan is ensured by forcing connectivity between adjacent angles (control points). It is envisioned that the resultant plans can be delivered accurately using the dose rate regulated tracking method which handles breathing irregularities (Yi et al 2008 Med. Phys. 35 3955-62).This planning process is straightforward and only adds a small step to current clinical 3D planning practice. Our 4D planning scheme was tested on three cases to evaluate dosimetric benefits. The created 4D-IMAT plans showed similar dose distributions as compared with the 3D-IMAT plans on a single static phase, indicating that our method is capable of eliminating the dosimetric effects of breathing induced target motion. Compared to the 3D-IMAT plans with large treatment margins encompassing respiratory motion, our 4D-IMAT plans reduced radiation doses to surrounding normal organs and tissues.

  17. Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nyflot, Matthew J., E-mail: nyflot@uw.edu; Lee, Tzu-Cheng; Alessio, Adam M.

    Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantommore » under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by the patient-specific respiratory waveforms; when testing patient and sinusoidal waveforms separately, patient waveforms were significantly different between phases (p < 0.0001) while the sinusoidal waveforms were not significantly different (p = 0.98). When considering only the subset of 4DMATCH images that corresponded to the end-exhale image phase, 4DEXH, mean and interquartile range were similar to 4DMATCH but variability was considerably reduced. Conclusions: Comparative advantages in accuracy and precision of SUV metrics and segmented volumes were demonstrated with the use of the maximum intensity projection and end-exhale CT attenuation correction. While respiratory phase-matched CTAC should in theory provide optimal corrections, image artifacts and differences in implementation of 4DCT and 4DPET sorting can degrade the benefit of this approach. These results may be useful to guide the implementation, analysis, and development of respiratory-correlated thoracic PET/CT in the radiation oncology and diagnostic settings.« less

  18. Observing the coach-created motivational environment across training and competition in youth sport.

    PubMed

    Smith, Nathan; Quested, Eleanor; Appleton, Paul R; Duda, Joan L

    2017-01-01

    Adopting an integrated achievement goal (Nicholls, J. G. (1989). The competitive ethos and democratic education. Cambridge, MA: Harvard University Press.) and self-determination theory (Deci, E. L., & Ryan, R. M. (2000). The "what" and "why" of goal pursuits: Human needs and the self-determination of behavior. Psychological Inquiry, 11, 227-268. doi:10.1207/S15327965PLI1104_01) perspective as proffered by Duda, J. L. (2013). (The conceptual and empirical foundations of empowering coaching TM : Setting the stage for the PAPA project. International Journal of Sport and Exercise Psychology, 11, 311-318. doi:10.1080/1612197X.2013.839414), the aim of the current study was to observe empowering and disempowering features of the multidimensional motivational coaching environment in training and competition in youth sport. Seventeen grass-roots soccer coaches were observed and rated in training and competitive settings using the multidimensional motivational climate observation system (MMCOS; Smith, N., Tessier, D., Tzioumakis, Y., Quested, E., Appleton, P., Sarrazin, P., … Duda, J. L. (2015). Development and validation of the multidimensional motivational climate observation system (MMCOS). Journal of Sport and Exercise Psychology, 37, 4-22. doi:10.1123/jsep.2014-0059). In line with our hypotheses, coaches created different motivational environments in the two contexts. More specifically, coaches were observed to create a less empowering and more disempowering environment in competition compared to in training. The observed differences were underpinned by distinctive motivational strategies used by coaches in the two contexts. Findings have implications for the assessment of the coach-created motivational environment and the promotion of quality motivation for young athletes taking part in grass-roots-level sport.

  19. Volumetric CT-images improve testing of radiological image interpretation skills.

    PubMed

    Ravesloot, Cécile J; van der Schaaf, Marieke F; van Schaik, Jan P J; ten Cate, Olle Th J; van der Gijp, Anouk; Mol, Christian P; Vincken, Koen L

    2015-05-01

    Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Two groups of medical students (n=139; n=143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students' test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p<.001). The volumetric CT-image testing program was considered user-friendly. This study shows that volumetric image questions can be successfully integrated in students' radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Preoperative localization strategies for primary hyperparathyroidism: an economic analysis.

    PubMed

    Lubitz, Carrie C; Stephen, Antonia E; Hodin, Richard A; Pandharipande, Pari

    2012-12-01

    Strategies for localizing parathyroid pathology preoperatively vary in cost and accuracy. Our purpose was to compute and compare comprehensive costs associated with common localization strategies. A decision-analytic model was developed to evaluate comprehensive, short-term costs of parathyroid localization strategies for patients with primary hyperparathyroidism. Eight strategies were compared. Probabilities of accurate localization were extracted from the literature, and costs associated with each strategy were based on 2011 Medicare reimbursement schedules. Differential cost considerations included outpatient versus inpatient surgeries, operative time, and costs of imaging. Sensitivity analyses were performed to determine effects of variability in key model parameters upon model results. Ultrasound (US) followed by 4D-CT was the least expensive strategy ($5,901), followed by US alone ($6,028), and 4D-CT alone ($6,110). Strategies including sestamibi (SM) were more expensive, with associated expenditures of up to $6,329 for contemporaneous US and SM. Four-gland, bilateral neck exploration (BNE) was the most expensive strategy ($6,824). Differences in cost were dependent upon differences in the sensitivity of each strategy for detecting single-gland disease, which determined the proportion of patients able to undergo outpatient minimally invasive parathyroidectomy. In sensitivity analysis, US alone was preferred over US followed by 4D-CT only when both the sensitivity of US alone for detecting an adenoma was ≥ 94 %, and the sensitivity of 4D-CT following negative US was ≤ 39 %. 4D-CT alone was the least costly strategy when US sensitivity was ≤ 31 %. Among commonly used strategies for preoperative localization of parathyroid pathology, US followed by selective 4D-CT is the least expensive.

  1. TU-G-BRA-02: Can We Extract Lung Function Directly From 4D-CT Without Deformable Image Registration?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kipritidis, J; Woodruff, H; Counter, W

    Purpose: Dynamic CT ventilation imaging (CT-VI) visualizes air volume changes in the lung by evaluating breathing-induced lung motion using deformable image registration (DIR). Dynamic CT-VI could enable functionally adaptive lung cancer radiation therapy, but its sensitivity to DIR parameters poses challenges for validation. We hypothesize that a direct metric using CT parameters derived from Hounsfield units (HU) alone can provide similar ventilation images without DIR. We compare the accuracy of Direct and Dynamic CT-VIs versus positron emission tomography (PET) images of inhaled {sup 68}Ga-labelled nanoparticles (‘Galligas’). Methods: 25 patients with lung cancer underwent Galligas 4D-PET/CT scans prior to radiation therapy.more » For each patient we produced three CT- VIs. (i) Our novel method, Direct CT-VI, models blood-gas exchange as the product of air and tissue density at each lung voxel based on time-averaged 4D-CT HU values. Dynamic CT-VIs were produced by evaluating: (ii) regional HU changes, and (iii) regional volume changes between the exhale and inhale 4D-CT phase images using a validated B-spline DIR method. We assessed the accuracy of each CT-VI by computing the voxel-wise Spearman correlation with free-breathing Galligas PET, and also performed a visual analysis. Results: Surprisingly, Direct CT-VIs exhibited better global correlation with Galligas PET than either of the dynamic CT-VIs. The (mean ± SD) correlations were (0.55 ± 0.16), (0.41 ± 0.22) and (0.29 ± 0.27) for Direct, Dynamic HU-based and Dynamic volume-based CT-VIs respectively. Visual comparison of Direct CT-VI to PET demonstrated similarity for emphysema defects and ventral-to-dorsal gradients, but inability to identify decreased ventilation distal to tumor-obstruction. Conclusion: Our data supports the hypothesis that Direct CT-VIs are as accurate as Dynamic CT-VIs in terms of global correlation with Galligas PET. Visual analysis, however, demonstrated that different CT-VI algorithms might have varying accuracy depending on the underlying cause of ventilation abnormality. This research was supported by a National Health and Medical Research Council (NHMRC) Australia Fellowship, an Cancer Institute New South Wales Early Career Fellowship 13-ECF-1/15 and NHMRC scholarship APP1038399. No commercial funding was received for this work.« less

  2. Estimation of Error in Maximal Intensity Projection-Based Internal Target Volume of Lung Tumors: A Simulation and Comparison Study Using Dynamic Magnetic Resonance Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cai Jing; Read, Paul W.; Baisden, Joseph M.

    Purpose: To evaluate the error in four-dimensional computed tomography (4D-CT) maximal intensity projection (MIP)-based lung tumor internal target volume determination using a simulation method based on dynamic magnetic resonance imaging (dMRI). Methods and Materials: Eight healthy volunteers and six lung tumor patients underwent a 5-min MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to generate re-sorted dMRI using 4D-CT acquisition methods (RedCAM) by segmenting and rebinning the MRI scans. The maximal intensity projection images were generated from RedCAM and dMRI, and the errors in the MIP-based internal target area (ITA)more » from RedCAM ({epsilon}), compared with those from dMRI, were determined and correlated with the subjects' respiratory variability ({nu}). Results: Maximal intensity projection-based ITAs from RedCAM were comparatively smaller than those from dMRI in both phantom studies ({epsilon} = -21.64% {+-} 8.23%) and lung tumor patient studies ({epsilon} = -20.31% {+-} 11.36%). The errors in MIP-based ITA from RedCAM correlated linearly ({epsilon} = -5.13{nu} - 6.71, r{sup 2} = 0.76) with the subjects' respiratory variability. Conclusions: Because of the low temporal resolution and retrospective re-sorting, 4D-CT might not accurately depict the excursion of a moving tumor. Using a 4D-CT MIP image to define the internal target volume might therefore cause underdosing and an increased risk of subsequent treatment failure. Patient-specific respiratory variability might also be a useful predictor of the 4D-CT-induced error in MIP-based internal target volume determination.« less

  3. Estimation of error in maximal intensity projection-based internal target volume of lung tumors: a simulation and comparison study using dynamic magnetic resonance imaging.

    PubMed

    Cai, Jing; Read, Paul W; Baisden, Joseph M; Larner, James M; Benedict, Stanley H; Sheng, Ke

    2007-11-01

    To evaluate the error in four-dimensional computed tomography (4D-CT) maximal intensity projection (MIP)-based lung tumor internal target volume determination using a simulation method based on dynamic magnetic resonance imaging (dMRI). Eight healthy volunteers and six lung tumor patients underwent a 5-min MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to generate re-sorted dMRI using 4D-CT acquisition methods (RedCAM) by segmenting and rebinning the MRI scans. The maximal intensity projection images were generated from RedCAM and dMRI, and the errors in the MIP-based internal target area (ITA) from RedCAM (epsilon), compared with those from dMRI, were determined and correlated with the subjects' respiratory variability (nu). Maximal intensity projection-based ITAs from RedCAM were comparatively smaller than those from dMRI in both phantom studies (epsilon = -21.64% +/- 8.23%) and lung tumor patient studies (epsilon = -20.31% +/- 11.36%). The errors in MIP-based ITA from RedCAM correlated linearly (epsilon = -5.13nu - 6.71, r(2) = 0.76) with the subjects' respiratory variability. Because of the low temporal resolution and retrospective re-sorting, 4D-CT might not accurately depict the excursion of a moving tumor. Using a 4D-CT MIP image to define the internal target volume might therefore cause underdosing and an increased risk of subsequent treatment failure. Patient-specific respiratory variability might also be a useful predictor of the 4D-CT-induced error in MIP-based internal target volume determination.

  4. Impact of 4D-(18)FDG-PET/CT imaging on target volume delineation in SBRT patients with central versus peripheral lung tumors. Multi-reader comparative study.

    PubMed

    Chirindel, Alin; Adebahr, Sonja; Schuster, Daniel; Schimek-Jasch, Tanja; Schanne, Daniel H; Nemer, Ursula; Mix, Michael; Meyer, Philipp; Grosu, Anca-Ligia; Brunner, Thomas; Nestle, Ursula

    2015-06-01

    Evaluation of the effect of co-registered 4D-(18)FDG-PET/CT for SBRT target delineation in patients with central versus peripheral lung tumors. Analysis of internal target volume (ITV) delineation of central and peripheral lung lesions in 21 SBRT-patients. Manual delineation was performed by 4 observers in 2 contouring phases: on respiratory gated 4DCT with diagnostic 3DPET available aside (CT-ITV) and on co-registered 4DPET/CT (PET/CT-ITV). Comparative analysis of volumes and inter-reader agreement. 11 cases of peripheral and 10 central lesions were evaluated. In peripheral lesions, average CT-ITV was 6.2 cm(3) and PET/CT-ITV 8.6 cm(3), resembling a mean change in hypothetical radius of 2 mm. For both CT-ITVs and PET/CT-ITVs inter reader agreement was good and unchanged (0.733 and 0.716; p=0.58). All PET/CT-ITVs stayed within the PTVs derived from CT-ITVs. In central lesions, average CT-ITVs were 42.1 cm(3), PET/CT-ITVs 44.2 cm(3), without significant overall volume changes. Inter-reader agreement improved significantly (0.665 and 0.750; p<0.05). 2/10 PET/CT-ITVs exceeded the PTVs derived from CT-ITVs by >1 ml in average for all observers. The addition of co-registered 4DPET data to 4DCT based target volume delineation for SBRT of centrally located lung tumors increases the inter-observer agreement and may help to avoid geographic misses. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Feasibility of a Single Contrast Bolus High-Pitch Pulmonary CT Angiography Protocol Followed by Low-Dose Retrospectively ECG-Gated Cardiac CT in Patients with Suspected Pulmonary Embolism.

    PubMed

    Schäfer, Julia Carmen; Haubenreisser, Holger; Meyer, Mathias; Grüttner, Joachim; Walter, Thomas; Borggrefe, Martin; Schoepf, Joseph U; Nance, John W; Schönberg, Stefan O; Henzler, Thomas

    2018-06-01

     To prospectively evaluate the feasibility of single contrast bolus high-pitch CT pulmonary angiography (CTPA) subsequently followed by low-dose retrospectively ECG-gated cardiac CT (4D-cCT) in patients with suspected pulmonary embolism (PE) to accurately evaluate right ventricular (RV) function.  62 patients (33 female, age 65.1 ± 17.5 years) underwent high-pitch CTPA examination with 80cc of iodinated contrast material. 5 s after the end of the high-pitch CTPA study, a low-dose retrospectively ECG-gated cardiac CT examination was automatically started. The volume CT dose index (CTDI vol) and dose length product (DLP) were recorded in all patients and the effective dose was calculated. For the assessment of image quality, attenuation was measured as Hounsfield units (HUs) within various regions of interest (ROIs). These ROIs were used to calculate the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality was assessed using a five-point Likert scale. On 4D-cCT, the ejection fraction of both ventricles (RVEF, LVEF) as well as the ratio of RVEF and LVEF (RVEF/LVEF) was assessed. The statistical difference of all parameters between the PE and non-PE group was calculated.  The mean effective radiation dose was 4.22 ± 2.05 mSv. Attenuation measurements on CTPA showed the highest attenuation values in the main pulmonary artery (442.01 ± 187.64). On 4D-cCT attenuation values were highest in the descending aorta (560.59 ± 208.81). The CNR and SNR values on CTPA were highest within the main pulmonary artery (CNR = 12.43 ± 4.57; SNR = 15.14 ± 4.90). On 4D-cCT images, the highest SNR and CNR could be measured in the descending aorta (CNR = 10.26 ± 5.57; SNR = 10.86 ± 5.17). The mean LVEF was 60.73 %± 14.65 %, and the mean RVEF was 44.90 %± 9.54 %. The mean RVEF/LVEF was 0.79 ± 0.29. There was no significant difference between the PE and non-PE group for either of the parameters.  The investigated combined CTPA and 4D-cCT protocol is feasible using a single contrast bolus and allows the evaluation of RV function in patients with suspected PE. Further studies have to evaluate the additional value of this protocol regarding risk stratification in patients with PE.   · High-pitch CTPA is fast enough to leave sufficient contrast material within the heart that can be used for an additional low-dose functional cardiac CT examination.. · The tube current of the evaluated 4D-cCT is reduced over the entire cardiac cycle without any full dose peak.. · Low-dose cardiac CT subsequently performed after high-pitch CTPA allows for detailed analysis of RV function.. · Schäfer JC, Haubenreisser H, Meyer M et al. Feasibility of a Single Contrast Bolus High-Pitch Pulmonary CT Angiography Protocol Followed by Low-Dose Retrospectively ECG-Gated Cardiac CT in Patients with Suspected Pulmonary Embolism. Fortschr Röntgenstr 2018; 190: 542 - 550. © Georg Thieme Verlag KG Stuttgart · New York.

  6. How many CT detector rows are necessary to perform adequate three dimensional visualization?

    PubMed

    Fischer, Lars; Tetzlaff, Ralf; Schöbinger, Max; Radeleff, Boris; Bruckner, Thomas; Meinzer, H P; Büchler, M W; Schemmer, Peter

    2010-06-01

    The technical development of computer tomography (CT) imaging has experienced great progress. As consequence, CT data to be used for 3D visualization is not only based on 4 row CTs and 16 row CTs but also on 64 row CTs, respectively. The main goal of this study was to examine whether the increased amount of CT detector rows is correlated with improved quality of the 3D images. All CTs were acquired during routinely performed preoperative evaluation. Overall, there were 12 data sets based on 4 detector row CT, 12 data sets based on 16 detector row CT, and 10 data sets based on 64 detector row CT. Imaging data sets were transferred to the DKFZ Heidelberg using the CHILI teleradiology system. For the analysis all CT scans were examined in a blinded fashion, i.e. both the name of the patient as well as the name of the CT brand were erased. For analysis, the time for segmentation of liver, both portal and hepatic veins as well as the branching depth of portal veins and hepatic veins was recorded automatically. In addition, all results were validated in a blinded fashion based on given quality index. Segmentation of the liver was performed in significantly shorter time (p<0.01, Kruskal-Wallis test) in the 16 row CT (median 479 s) compared to 4 row CT (median 611 s), and 64 row CT (median 670 s), respectively. The branching depth of the portal vein did not differ significantly among the 3 different data sets (p=0.37, Kruskal-Wallis test). However, the branching depth of the hepatic veins was significantly better (p=0.028, Kruskal-Wallis test) in the 4 row CT and 16 row CT compared to 64 row CT. The grading of the quality index was not statistically different for portal veins and hepatic veins (p=0.80, Kruskal-Wallis test). Even though the total quality index was better for the vessel tree based on 64 row CT data sets (mean scale 2.6) compared to 4 CT row data (mean scale 3.25) and 16 row CT data (mean scale 3.0), these differences did not reach statistical difference (p=0.53, Kruskal-Wallis test). Even though 3D visualization is useful in operation planning, the quality of the 3D images appears to be not dependent of the number of CT detector rows. Copyright (c) 2009. Published by Elsevier Ireland Ltd.

  7. MO-FG-CAMPUS-TeP3-01: A Model of Baseline Shift to Improve Robustness of Proton Therapy Treatments of Moving Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Souris, K; Barragan Montero, A; Di Perri, D

    Purpose: The shift in mean position of a moving tumor also known as “baseline shift”, has been modeled, in order to automatically generate uncertainty scenarios for the assessment and robust optimization of proton therapy treatments in lung cancer. Methods: An average CT scan and a Mid-Position CT scan (MidPCT) of the patient at the planning time are first generated from a 4D-CT data. The mean position of the tumor along the breathing cycle is represented by the GTV contour in the MidPCT. Several studies reported both systematic and random variations of the mean tumor position from fraction to fraction. Ourmore » model can simulate this baseline shift by generating a local deformation field that moves the tumor on all phases of the 4D-CT, without creating any non-physical artifact. The deformation field is comprised of normal and tangential components with respect to the lung wall in order to allow the tumor to slip within the lung instead of deforming the lung surface. The deformation field is eventually smoothed in order to enforce its continuity. Two 4D-CT series acquired at 1 week of interval were used to validate the model. Results: Based on the first 4D-CT set, the model was able to generate a third 4D-CT that reproduced the 5.8 mm baseline-shift measured in the second 4D-CT. Water equivalent thickness (WET) of the voxels have been computed for the 3 average CTs. The root mean square deviation of the WET in the GTV is 0.34 mm between week 1 and week 2, and 0.08 mm between the simulated data and week 2. Conclusion: Our model can be used to automatically generate uncertainty scenarios for robustness analysis of a proton therapy plan. The generated scenarios can also feed a TPS equipped with a robust optimizer. Kevin Souris, Ana Barragan, and Dario Di Perri are financially supported by Televie Grants from F.R.S.-FNRS.« less

  8. Analysis and modification of verbal coaching behaviour: the usefulness of a data-driven intervention strategy.

    PubMed

    More, K G; Franks, I M

    1996-12-01

    This study tested a computer-aided coaching analysis instrument (CAI) as part of an intervention strategy designed to modify verbal coaching behaviour. Four coaches were observed and analysed over 12 practice sessions. Coaches A, B and C received intervention feedback through CAI data, where selected behaviours were highlighted for discussion, and videotape images were used to illustrate discussion points. Coach D was provided with videotapes of his own performance and told to formulate and implement any of his own recommendations. The CAI data are primarily quantitative, so target values were created for the different dimensions of verbal behaviour. This benefited the coaches in interpreting their effectiveness and provided a reference to evaluate the magnitude of change. Written journals and audiotape recordings were also used to promote insight into the complexity of verbal behaviour and the "human factors' (e.g. relationship with players, attitude to researcher) that affect behaviour modification. Instructional effectiveness was assessed by time-series analysis. There was evidence from each behaviour dimension that change can occur and be maintained as a result of exposure to the CAI intervention strategy. However, this is clearly contingent upon the coach understanding what is asked of him or her, and remains focused and committed to changing these particular behaviours. The analysis of Coach D's behavioural change suggests there are limitations to the sensitivity of discretionary viewing, as only two dimensions of behaviour were identified for, and resulted in, positive change. The results of this study provide support for Locke's (1984) contention that behaviour modification can occur by using data as direct feedback, as reinforcement and as information in the form of recommendations. However, the study also illuminates several factors that can negate the modification and maintenance of verbal coaching behaviour.

  9. A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

    PubMed

    Yan, Hao; Zhen, Xin; Folkerts, Michael; Li, Yongbao; Pan, Tinsu; Cervino, Laura; Jiang, Steve B; Jia, Xun

    2014-07-01

    4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3-0.5 mm for patients 1-3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1-1.5 min per phase. High-quality 4D-CBCT imaging based on the clinically standard 1-min 3D CBCT scanning protocol is feasible via the proposed hybrid reconstruction algorithm.

  10. An RCT of Nurse Coaching vs. Herbal CAM for Soldier Weight Reduction

    DTIC Science & Technology

    2015-12-08

    Coaching vs. Herbal CAM for Soldier Weight Reduction 5b. GRANT NUMBER HT9404-12-1-TS03 5c. PROGRAM ELEMENT NUMBER N/A 6. AUTHOR(S) 5d...coaching intervention and an herbal supplement for Service Member (SM) weight reduction over a 12-week period to evaluate their effectiveness...Title of Research Study or Evidence-Based Practice (EBP) Project An RCT of Nurse Coaching vs. Herbal CAM for Soldier Weight Reduction Period of Award

  11. Directional sinogram interpolation for motion weighted 4D cone-beam CT reconstruction

    NASA Astrophysics Data System (ADS)

    Zhang, Hua; Kruis, Matthijs; Sonke, Jan-Jakob

    2017-03-01

    The image quality of respiratory sorted four-dimensional (4D) cone-beam (CB) computed tomography (CT) is often limited by streak artifacts due to insufficient projections. A motion weighted reconstruction (MWR) method is proposed to decrease streak artifacts and improve image quality. Firstly, respiratory correlated CBCT projections were interpolated by directional sinogram interpolation (DSI) to generate additional CB projections for each phase and subsequently reconstructed. Secondly, local motion was estimated by deformable image registration of the interpolated 4D CBCT. Thirdly, a regular 3D FDK CBCT was reconstructed from the non-interpolated projections. Finally, weights were assigned to each voxel, based on the local motion, and then were used to combine the 3D FDK CBCT and interpolated 4D CBCT to generate the final 4D image. MWR method was compared with regular 4D CBCT scans as well as McKinnon and Bates (MKB) based reconstructions. Comparisons were made in terms of (1) comparing the steepness of an extracted profile from the boundary of the region-of-interest (ROI), (2) contrast-to-noise ratio (CNR) inside certain ROIs, and (3) the root-mean-square-error (RMSE) between the planning CT and CBCT inside a homogeneous moving region. Comparisons were made for both a phantom and four patient scans. In a 4D phantom, RMSE were reduced by 24.7% and 38.7% for MKB and MWR respectively, compared to conventional 4D CBCT. Meanwhile, interpolation induced blur was minimal in static regions for MWR based reconstructions. In regions with considerable respiratory motion, image blur using MWR is less than the MKB and 3D Feldkamp (FDK) methods. In the lung cancer patients, average CNRs of MKB, DSI and MWR improved by a factor 1.7, 2.8 and 3.5 respectively relative to 4D FDK. MWR effectively reduces RMSE in 4D cone-beam CT and improves the image quality in both the static and respiratory moving regions compared to 4D FDK and MKB methods.

  12. Directional sinogram interpolation for motion weighted 4D cone-beam CT reconstruction.

    PubMed

    Zhang, Hua; Kruis, Matthijs; Sonke, Jan-Jakob

    2017-03-21

    The image quality of respiratory sorted four-dimensional (4D) cone-beam (CB) computed tomography (CT) is often limited by streak artifacts due to insufficient projections. A motion weighted reconstruction (MWR) method is proposed to decrease streak artifacts and improve image quality. Firstly, respiratory correlated CBCT projections were interpolated by directional sinogram interpolation (DSI) to generate additional CB projections for each phase and subsequently reconstructed. Secondly, local motion was estimated by deformable image registration of the interpolated 4D CBCT. Thirdly, a regular 3D FDK CBCT was reconstructed from the non-interpolated projections. Finally, weights were assigned to each voxel, based on the local motion, and then were used to combine the 3D FDK CBCT and interpolated 4D CBCT to generate the final 4D image. MWR method was compared with regular 4D CBCT scans as well as McKinnon and Bates (MKB) based reconstructions. Comparisons were made in terms of (1) comparing the steepness of an extracted profile from the boundary of the region-of-interest (ROI), (2) contrast-to-noise ratio (CNR) inside certain ROIs, and (3) the root-mean-square-error (RMSE) between the planning CT and CBCT inside a homogeneous moving region. Comparisons were made for both a phantom and four patient scans. In a 4D phantom, RMSE were reduced by 24.7% and 38.7% for MKB and MWR respectively, compared to conventional 4D CBCT. Meanwhile, interpolation induced blur was minimal in static regions for MWR based reconstructions. In regions with considerable respiratory motion, image blur using MWR is less than the MKB and 3D Feldkamp (FDK) methods. In the lung cancer patients, average CNRs of MKB, DSI and MWR improved by a factor 1.7, 2.8 and 3.5 respectively relative to 4D FDK. MWR effectively reduces RMSE in 4D cone-beam CT and improves the image quality in both the static and respiratory moving regions compared to 4D FDK and MKB methods.

  13. The contribution of lifestyle coaching of overweight patients in primary care to more autonomous motivation for physical activity and healthy dietary behaviour: results of a longitudinal study.

    PubMed

    Rutten, Geert M; Meis, Jessie J M; Hendriks, Marike R C; Hamers, Femke J M; Veenhof, Cindy; Kremers, Stef P J

    2014-07-16

    Combined lifestyle interventions (CLIs) have been advocated as an effective instrument in efforts to reduce overweight and obesity. The odds of maintaining higher levels of physical activity (PA) and healthier dietary behaviour improve when people are more intrinsically motivated to change their behaviour. To promote the shift towards more autonomous types of motivation, facilitator led CLIs have been developed including lifestyle coaching as key element. The present study examined the shift in types of motivation to increase PA and healthy dieting among participants of a primary care CLI, and the contribution of lifestyle coaching to potential changes in motivational quality. This prospective cohort study included participants of 29 general practices in the Netherlands that implemented a CLI named 'BeweegKuur'. Questionnaires including items on demographics, lifestyle coaching and motivation were sent at baseline and after 4 months. Aspects of motivation were assessed with the Behavioural Regulation and Exercise Questionnaire (BREQ-2) and the Regulation of Eating Behaviour Questionnaire (REBS). We performed a drop out analysis to identify selective drop-out. Changes in motivation were analysed with t-tests and effect size interpretations (Cohen's d), and multivariate regression analysis was used to identify predictors of motivational change. For physical activity, changes in motivational regulation were fully in line with the tenets of Self Determination Theory and Motivational Interviewing: participants made a shift towards a more autonomous type of motivation (i.e. controlled types of motivation decreased and autonomous types increased). Moreover, an autonomy supportive coaching style was generally found to predict a larger shift in autonomous types of motivation. For healthy dietary behaviour, however, except for a small decrease in external motivation, no favourable changes in different types of motivation were observed. The relation between coaching and motivation appeared to be influenced by the presence of physical activity guidance in the programme. Motivation of participants of a real life primary care CLI had changed towards a more autonomous motivation after 4 months of intervention. Autonomy-supportive lifestyle coaching contributed to this change with respect to physical activity. Lifestyle coaching for healthy diet requires thorough knowledge about the problem of unhealthy dieting and solid coaching skills.

  14. The contribution of lifestyle coaching of overweight patients in primary care to more autonomous motivation for physical activity and healthy dietary behaviour: results of a longitudinal study

    PubMed Central

    2014-01-01

    Background Combined lifestyle interventions (CLIs) have been advocated as an effective instrument in efforts to reduce overweight and obesity. The odds of maintaining higher levels of physical activity (PA) and healthier dietary behaviour improve when people are more intrinsically motivated to change their behaviour. To promote the shift towards more autonomous types of motivation, facilitator led CLIs have been developed including lifestyle coaching as key element. The present study examined the shift in types of motivation to increase PA and healthy dieting among participants of a primary care CLI, and the contribution of lifestyle coaching to potential changes in motivational quality. Methods This prospective cohort study included participants of 29 general practices in the Netherlands that implemented a CLI named ‘BeweegKuur’. Questionnaires including items on demographics, lifestyle coaching and motivation were sent at baseline and after 4 months. Aspects of motivation were assessed with the Behavioural Regulation and Exercise Questionnaire (BREQ-2) and the Regulation of Eating Behaviour Questionnaire (REBS). We performed a drop out analysis to identify selective drop-out. Changes in motivation were analysed with t-tests and effect size interpretations (Cohen’s d), and multivariate regression analysis was used to identify predictors of motivational change. Results For physical activity, changes in motivational regulation were fully in line with the tenets of Self Determination Theory and Motivational Interviewing: participants made a shift towards a more autonomous type of motivation (i.e. controlled types of motivation decreased and autonomous types increased). Moreover, an autonomy supportive coaching style was generally found to predict a larger shift in autonomous types of motivation. For healthy dietary behaviour, however, except for a small decrease in external motivation, no favourable changes in different types of motivation were observed. The relation between coaching and motivation appeared to be influenced by the presence of physical activity guidance in the programme. Conclusions Motivation of participants of a real life primary care CLI had changed towards a more autonomous motivation after 4 months of intervention. Autonomy-supportive lifestyle coaching contributed to this change with respect to physical activity. Lifestyle coaching for healthy diet requires thorough knowledge about the problem of unhealthy dieting and solid coaching skills. PMID:25027848

  15. Influence of technical parameters on epicardial fat volume quantification at cardiac CT.

    PubMed

    Bucher, Andreas M; Joseph Schoepf, U; Krazinski, Aleksander W; Silverman, Justin; Spearman, James V; De Cecco, Carlo N; Meinel, Felix G; Vogl, Thomas J; Geyer, Lucas L

    2015-06-01

    To systematically analyze the influence of technical parameters on quantification of epicardial fat volume (EATV) at cardiac CT. 153 routine cardiac CT data sets were analyzed using three-dimensional pericardial border delineation. Three image series were reconstructed per patient: (a) CTAD: coronary CT angiography (CTA), diastolic phase; (b) CTAS: coronary CTA, systolic phase; (c) CaScD: non-contrast CT, diastolic phase. EATV was calculated using three different upper thresholds (-15HU, -30 HU, -45HU). Repeated measures ANOVA, Spearman's rho, and Bland Altman plots were used. Mean EATV differed between all three image series at a -30HU threshold (CTAD 87.2 ± 38.5 ml, CTAS 90.9 ± 37.7 ml, CaScD 130.7 ± 49.5 ml, P<0.001). EATV of diastolic and systolic CTA reconstructions did not differ significantly (P=0.225). Mean EATV for contrast enhanced CTA at a -15HU threshold (CTAD15 102.4 ± 43.6 ml, CTAS15 105.3 ± 42.3 ml) could be approximated most closely by non-contrast CT at -45HU threshold (CaScD45 105.3 ± 40.8 ml). The correlation was excellent: CTAS15-CTAD15, rho=0.943; CTAD15-CaScD45, rho=0.905; CTAS15-CaScD45, rho=0.924; each P<0.001). Bias values from Bland Altman Analysis were: CTAS15-CTAD15, 4.9%; CTAD15-CaScD45, -4.3%; CTAS15-CaScD45, 0.6%. Measured EATV can differ substantially between contrast enhanced and non-contrast CT studies, which can be reconciled by threshold modification. Heart cycle phase does not significantly influence EATV measurements. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. dNP2-ctCTLA-4 inhibits German cockroach extract-induced allergic airway inflammation and hyper-responsiveness via inhibition of Th2 responses

    PubMed Central

    Lim, Sangho; Ho Sohn, Jung; Koo, Ja-Hyun; Park, Jung-Won; Choi, Je-Min

    2017-01-01

    German cockroaches are major household allergens that can trigger allergic airway inflammatory diseases with sensitive T-cell responses. Although the use of immune modulatory biologics, such as antibodies, to mediate allergic responses has recently been examined, only systemic administration is available because of the size limitations on intranasal administration. Here we utilized a cell-permeable peptide, dNP2, to deliver the cytoplasmic domain of cytotoxic T-lymphocyte antigen-4 (ctCTLA-4) through the airway epithelium to modulate Th2 responses in a German cockroach extract (GCE)-induced allergic airway inflammation model. The intranasal delivery efficiency of the dNP2-dTomato protein to the lungs was higher in GCE-induced asthmatic lung parenchymal cells compared to the sham cells. Intranasal administration of the dNP2-ctCTLA-4 protein inhibited airway hyper-responsiveness and reduced airway inflammation and remodeling, including goblet cell metaplasia and collagen deposition around the bronchi. The number of infiltrated cells, including eosinophils, and the levels of IL-4, IL-5, IL-13 and IFN-γ in the lungs were significantly reduced, presumably owing to inhibition of Th2 differentiation. However, intranasal administration of CTLA4-Ig did not inhibit airway inflammation. These results collectively suggest that dNP2-ctCTLA-4 is an efficient intranasally applicable candidate biologic for treating allergic asthma. PMID:28775364

  17. dNP2-ctCTLA-4 inhibits German cockroach extract-induced allergic airway inflammation and hyper-responsiveness via inhibition of Th2 responses.

    PubMed

    Lim, Sangho; Ho Sohn, Jung; Koo, Ja-Hyun; Park, Jung-Won; Choi, Je-Min

    2017-08-04

    German cockroaches are major household allergens that can trigger allergic airway inflammatory diseases with sensitive T-cell responses. Although the use of immune modulatory biologics, such as antibodies, to mediate allergic responses has recently been examined, only systemic administration is available because of the size limitations on intranasal administration. Here we utilized a cell-permeable peptide, dNP2, to deliver the cytoplasmic domain of cytotoxic T-lymphocyte antigen-4 (ctCTLA-4) through the airway epithelium to modulate Th2 responses in a German cockroach extract (GCE)-induced allergic airway inflammation model. The intranasal delivery efficiency of the dNP2-dTomato protein to the lungs was higher in GCE-induced asthmatic lung parenchymal cells compared to the sham cells. Intranasal administration of the dNP2-ctCTLA-4 protein inhibited airway hyper-responsiveness and reduced airway inflammation and remodeling, including goblet cell metaplasia and collagen deposition around the bronchi. The number of infiltrated cells, including eosinophils, and the levels of IL-4, IL-5, IL-13 and IFN-γ in the lungs were significantly reduced, presumably owing to inhibition of Th2 differentiation. However, intranasal administration of CTLA4-Ig did not inhibit airway inflammation. These results collectively suggest that dNP2-ctCTLA-4 is an efficient intranasally applicable candidate biologic for treating allergic asthma.

  18. A navigation system for flexible endoscopes using abdominal 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Hoffmann, R.; Kaar, M.; Bathia, Amon; Bathia, Amar; Lampret, A.; Birkfellner, W.; Hummel, J.; Figl, M.

    2014-09-01

    A navigation system for flexible endoscopes equipped with ultrasound (US) scan heads is presented. In contrast to similar systems, abdominal 3D-US is used for image fusion of the pre-interventional computed tomography (CT) to the endoscopic US. A 3D-US scan, tracked with an optical tracking system (OTS), is taken pre-operatively together with the CT scan. The CT is calibrated using the OTS, providing the transformation from CT to 3D-US. Immediately before intervention a 3D-US tracked with an electromagnetic tracking system (EMTS) is acquired and registered intra-modal to the preoperative 3D-US. The endoscopic US is calibrated using the EMTS and registered to the pre-operative CT by an intra-modal 3D-US/3D-US registration. Phantom studies showed a registration error for the US to CT registration of 5.1 mm ± 2.8 mm. 3D-US/3D-US registration of patient data gave an error of 4.1 mm compared to 2.8 mm with the phantom. From this we estimate an error on patient experiments of 5.6 mm.

  19. Cost-effectiveness analysis for a tele-based health coaching program for chronic disease in primary care.

    PubMed

    Oksman, Erja; Linna, Miika; Hörhammer, Iiris; Lammintakanen, Johanna; Talja, Martti

    2017-02-15

    The burden of chronic disease and multimorbidity is rapidly increasing. Self-management support interventions are effective in reduce cost, especially when targeted at a single disease group; however, economical evidence of such complex interventions remains scarce. The objective of this study was to evaluate a cost-effectiveness analysis of a tele-based health-coaching intervention among patients with type 2 diabetes (T2D), coronary artery disease (CAD) and congestive heart failure (CHF). A total of 1570 patients were blindly randomized to intervention (n = 970) and control (n = 470) groups. The intervention group received monthly individual health coaching by telephone from a specially trained nurse for 12-months in addition to routine social and healthcare. Patients in the control group received routine social and health care. Quality of life was assessed at the beginning of the intervention and follow-up measurements were made after 12 months health coaching. The cost included all direct health-care costs supplemented with home care and nursing home-care costs in social care. Utility was based on a Health Related Quality of Life (HRQoL) measurement (15D instrument), and cost effectiveness was assessed using incremental cost-effectiveness ratios (ICERs). The cost-effectiveness of health coaching was highest in the T2D group (ICER €20,000 per Quality-Adjusted Life Years [QALY]). The ICER for the CAD group was more modest (€40,278 per QALY), and in the CHF group, costs increased with no marked effect on QoL. Probabilistic sensitivity analysis indicated that at the societal willingness to pay threshold of €50,000 per QALY, the probability of health coaching being cost effective was 55% in the whole study group. The cost effectiveness of health coaching may vary substantially across patient groups, and thus interventions should be targeted at selected subgroups of chronically ill. Based on the results of this study, health coaching improved the QoL of T2D and CAD patients with moderate costs. However, the results are grounded on a short follow-up period, and more evidence is needed to evaluate the long-term outcomes of health-coaching programs. NCT00552903 [Prospectively registered, registration date 1 st November 2007, last updated 3 rd February 2009].

  20. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging

    NASA Astrophysics Data System (ADS)

    Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V.; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L.; Beauchemin, Steven S.; Rodrigues, George; Gaede, Stewart

    2015-02-01

    This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51  ±  1.92) to (97.27  ±  0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.

  1. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging.

    PubMed

    Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L; Beauchemin, Steven S; Rodrigues, George; Gaede, Stewart

    2015-02-21

    This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51  ±  1.92) to (97.27  ±  0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.

  2. Career Coaches as a Source of Vicarious Learning for Racial and Ethnic Minority PhD Students in the Biomedical Sciences: A Qualitative Study.

    PubMed

    Williams, Simon N; Thakore, Bhoomi K; McGee, Richard

    2016-01-01

    Many recent mentoring initiatives have sought to help improve the proportion of underrepresented racial and ethnic minorities (URMs) in academic positions across the biomedical sciences. However, the intractable nature of the problem of underrepresentation suggests that many young scientists may require supplemental career development beyond what many mentors are able to offer. As an adjunct to traditional scientific mentoring, we created a novel academic career "coaching" intervention for PhD students in the biomedical sciences. To determine whether and how academic career coaches can provide effective career-development-related learning experiences for URM PhD students in the biomedical sciences. We focus specifically on vicarious learning experiences, where individuals learn indirectly through the experiences of others. The intervention is being tested as part of a longitudinal randomized control trial (RCT). Here, we describe a nested qualitative study, using a framework approach to analyze data from a total of 48 semi-structured interviews from 24 URM PhD students (2 interviews per participant, 1 at baseline, 1 at 12-month follow-up) (16 female, 8 male; 11 Black, 12 Hispanic, 1 Native-American). We explored the role of the coach as a source of vicarious learning, in relation to the students' goal of being future biomedical science faculty. Coaches were resources through which most students in the study were able to learn vicariously about how to pursue, and succeed within, an academic career. Coaches were particularly useful in instances where students' research mentors are unable to provide such vicarious learning opportunities, for example because the mentor is too busy to have career-related discussions with a student, or because they have, or value, a different type of academic career to the type the student hopes to achieve. Coaching can be an important way to address the lack of structured career development that students receive in their home training environment.

  3. Quantifying glenoid bone loss in anterior shoulder instability: reliability and accuracy of 2-dimensional and 3-dimensional computed tomography measurement techniques.

    PubMed

    Bois, Aaron J; Fening, Stephen D; Polster, Josh; Jones, Morgan H; Miniaci, Anthony

    2012-11-01

    Glenoid support is critical for stability of the glenohumeral joint. An accepted noninvasive method of quantifying glenoid bone loss does not exist. To perform independent evaluations of the reliability and accuracy of standard 2-dimensional (2-D) and 3-dimensional (3-D) computed tomography (CT) measurements of glenoid bone deficiency. Descriptive laboratory study. Two sawbone models were used; one served as a model for 2 anterior glenoid defects and the other for 2 anteroinferior defects. For each scapular model, predefect and defect data were collected for a total of 6 data sets. Each sample underwent 3-D laser scanning followed by CT scanning. Six physicians measured linear indicators of bone loss (defect length and width-to-length ratio) on both 2-D and 3-D CT and quantified bone loss using the glenoid index method on 2-D CT and using the glenoid index, ratio, and Pico methods on 3-D CT. The intraclass correlation coefficient (ICC) was used to assess agreement, and percentage error was used to compare radiographic and true measurements. With use of 2-D CT, the glenoid index and defect length measurements had the least percentage error (-4.13% and 7.68%, respectively); agreement was very good (ICC, .81) for defect length only. With use of 3-D CT, defect length (0.29%) and the Pico(1) method (4.93%) had the least percentage error. Agreement was very good for all linear indicators of bone loss (range, .85-.90) and for the ratio linear and Pico surface area methods used to quantify bone loss (range, .84-.98). Overall, 3-D CT results demonstrated better agreement and accuracy compared to 2-D CT. None of the methods assessed in this study using 2-D CT was found to be valid, and therefore, 2-D CT is not recommended for these methods. However, the length of glenoid defects can be reliably and accurately measured on 3-D CT. The Pico and ratio techniques are most reliable; however, the Pico(1) method accurately quantifies glenoid bone loss in both the anterior and anteroinferior locations. Future work is required to implement valid imaging techniques of glenoid bone loss into clinical practice. This is one of the only studies to date that has investigated both the reliability and accuracy of multiple indicators and quantification methods that evaluate glenoid bone loss in anterior glenohumeral instability. These data are critical to ensure valid methods are used for preoperative assessment and to determine when a glenoid bone augmentation procedure is indicated.

  4. TU-AB-202-05: GPU-Based 4D Deformable Image Registration Using Adaptive Tetrahedral Mesh Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong, Z; Zhuang, L; Gu, X

    Purpose: Deformable image registration (DIR) has been employed today as an automated and effective segmentation method to transfer tumor or organ contours from the planning image to daily images, instead of manual segmentation. However, the computational time and accuracy of current DIR approaches are still insufficient for online adaptive radiation therapy (ART), which requires real-time and high-quality image segmentation, especially in a large datasets of 4D-CT images. The objective of this work is to propose a new DIR algorithm, with fast computational speed and high accuracy, by using adaptive feature-based tetrahedral meshing and GPU-based parallelization. Methods: The first step ismore » to generate the adaptive tetrahedral mesh based on the image features of a reference phase of 4D-CT, so that the deformation can be well captured and accurately diffused from the mesh vertices to voxels of the image volume. Subsequently, the deformation vector fields (DVF) and other phases of 4D-CT can be obtained by matching each phase of the target 4D-CT images with the corresponding deformed reference phase. The proposed 4D DIR method is implemented on GPU, resulting in significantly increasing the computational efficiency due to its parallel computing ability. Results: A 4D NCAT digital phantom was used to test the efficiency and accuracy of our method. Both the image and DVF results show that the fine structures and shapes of lung are well preserved, and the tumor position is well captured, i.e., 3D distance error is 1.14 mm. Compared to the previous voxel-based CPU implementation of DIR, such as demons, the proposed method is about 160x faster for registering a 10-phase 4D-CT with a phase dimension of 256×256×150. Conclusion: The proposed 4D DIR method uses feature-based mesh and GPU-based parallelism, which demonstrates the capability to compute both high-quality image and motion results, with significant improvement on the computational speed.« less

  5. Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume.

    PubMed

    Admiraal, Marjan A; Schuring, Danny; Hurkmans, Coen W

    2008-01-01

    The purpose of this study was to determine the 4D accumulated dose delivered to the CTV in stereotactic radiotherapy of lung tumours, for treatments planned on an average CT using an ITV derived from the Maximum Intensity Projection (MIP) CT. For 10 stage I lung cancer patients, treatment plans were generated based on 4D-CT images. From the 4D-CT scan, 10 time-sorted breathing phases were derived, along with the average CT and the MIP. The ITV with a margin of 0mm was used as a PTV to study a worst case scenario in which the differences between 3D planning and 4D dose accumulation will be largest. Dose calculations were performed on the average CT. Dose prescription was 60Gy to 95% of the PTV, and at least 54Gy should be received by 99% of the PTV. Plans were generated using the inverse planning module of the Pinnacle(3) treatment planning system. The plans consisted of nine coplanar beams with two segments each. After optimisation, the treatment plan was transferred to all breathing phases and the delivered dose per phase was calculated using an elastic body spline model available in our research version of Pinnacle (8.1r). Then, the cumulative dose to the CTV over all breathing phases was calculated and compared to the dose distribution of the original treatment plan. Although location, tumour size and breathing-induced tumour movement varied widely between patients, the PTV planning criteria could always be achieved without compromising organs at risk criteria. After 4D dose calculations, only very small differences between the initial planned PTV coverage and resulting CTV coverage were observed. For all patients, the dose delivered to 99% of the CTV exceeded 54Gy. For nine out of 10 patients also the criterion was met that the volume of the CTV receiving at least the prescribed dose was more than 95%. When the target dose is prescribed to the ITV (PTV=ITV) and dose calculations are performed on the average CT, the cumulative CTV dose compares well to the planned dose to the ITV. Thus, the concept of treatment plan optimisation and evaluation based on the average CT and the ITV is a valid approach in stereotactic lung treatment. Even with a zero ITV to PTV margin, no significantly different dose coverage of the CTV arises from the breathing motion induced dose variation over time.

  6. Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation.

    PubMed

    Coolens, Catherine; Bracken, John; Driscoll, Brandon; Hope, Andrew; Jaffray, David

    2012-05-01

    Conventional (i.e., respiratory-correlated) 4DCT exploits the repetitive nature of breathing to provide an estimate of motion; however, it has limitations due to binning artifacts and irregular breathing in actual patient breathing patterns. The aim of this work was to evaluate the accuracy and image quality of a dynamic volume, CT approach (4D(vol)) using a 320-slice CT scanner to minimize these limitations, wherein entire image volumes are acquired dynamically without couch movement. This will be compared to the conventional respiratory-correlated 4DCT approach (RCCT). 4D(vol) CT was performed and characterized on an in-house, programmable respiratory motion phantom containing multiple geometric and morphological "tumor" objects over a range of regular and irregular patient breathing traces obtained from 3D fluoroscopy and compared to RCCT. The accuracy of volumetric capture and breathing displacement were evaluated and compared with the ground truth values and with the results reported using RCCT. A motion model was investigated to validate the number of motion samples needed to obtain accurate motion probability density functions (PDF). The impact of 4D image quality on this accuracy was then investigated. Dose measurements using volumetric and conventional scan techniques were also performed and compared. Both conventional and dynamic volume 4DCT methods were capable of estimating the programmed displacement of sinusoidal motion, but patient breathing is known to not be regular, and obvious differences were seen for realistic, irregular motion. The mean RCCT amplitude error averaged at 4 mm (max. 7.8 mm) whereas the 4D(vol) CT error stayed below 0.5 mm. Similarly, the average absolute volume error was lower with 4D(vol) CT. Under irregular breathing, the 4D(vol) CT method provides a close description of the motion PDF (cross-correlation 0.99) and is able to track each object, whereas the RCCT method results in a significantly different PDF from the ground truth, especially for smaller tumors (cross-correlation ranging between 0.04 and 0.69). For the protocols studied, the dose measurements were higher in the 4D(vol) CT method (40%), but it was shown that significant mAs reductions can be achieved by a factor of 4-5 while maintaining image quality and accuracy. 4D(vol) CT using a scanner with a large cone-angle is a promising alternative for improving the accuracy with which respiration-induced motion can be characterized, particularly for patients with irregular breathing motion. This approach also generates 4DCT image data with a reduced total scan time compared to a RCCT scan, without the need for image binning or external respiration signals within the 16 cm scan length. Scan dose can be made comparable to RCCT by optimization of the scan parameters. In addition, it provides the possibility of measuring breathing motion for more than one breathing cycle to assess stability and obtain a more accurate motion PDF, which is currently not feasible with the conventional RCCT approach.

  7. Strength and conditioning practices of National Basketball Association strength and conditioning coaches.

    PubMed

    Simenz, Christopher J; Dugan, Carrie A; Ebben, William P

    2005-08-01

    This study describes the results of a survey of the practices of National Basketball Association strength and conditioning (NBA S&C) coaches. The response rate was 68.9% (20 of 29). This survey examines (a) background information, (b) physical testing, (c) flexibility development, (d) speed development, (e) plyometrics, (f) strength/power development, (g) unique aspects, and (h) comments from coaches providing additional information. Results indicate, in part, that coaches assess an average of 7.3 parameters of fitness, with body composition testing being the most common. All coaches used a variety of flexibility development strategies. Results reveal that 17 of 20 (85.0%) of NBA S&C coaches follow a periodization model. Nineteen of 20 coaches (95.0%) indicated that their athletes used Olympic-style lifts. All coaches employed plyometric exercises with their athletes. The squat and its variations, as well as the Olympic-style lifts and their variations, were the most frequently used exercises. The survey serves as a review and a source of applied information and new ideas.

  8. Brain tissue segmentation in 4D CT using voxel classification

    NASA Astrophysics Data System (ADS)

    van den Boom, R.; Oei, M. T. H.; Lafebre, S.; Oostveen, L. J.; Meijer, F. J. A.; Steens, S. C. A.; Prokop, M.; van Ginneken, B.; Manniesing, R.

    2012-02-01

    A method is proposed to segment anatomical regions of the brain from 4D computer tomography (CT) patient data. The method consists of a three step voxel classification scheme, each step focusing on structures that are increasingly difficult to segment. The first step classifies air and bone, the second step classifies vessels and the third step classifies white matter, gray matter and cerebrospinal fluid. As features the time averaged intensity value and the temporal intensity change value were used. In each step, a k-Nearest-Neighbor classifier was used to classify the voxels. Training data was obtained by placing regions of interest in reconstructed 3D image data. The method has been applied to ten 4D CT cerebral patient data. A leave-one-out experiment showed consistent and accurate segmentation results.

  9. On becoming a coach: a pilot intervention study with managers in long-term care.

    PubMed

    Cummings, Greta; Mallidou, Anastasia A; Masaoud, Elmabrok; Kumbamu, Ashok; Schalm, Corinne; Spence Laschinger, Heather K; Estabrooks, Carole A

    2014-01-01

    Health care leaders have called for the development of communication and leadership skills to improve manager-employee relationships, employee job satisfaction, quality care, and work environments. The aim of the study reported here was to pilot how a 2-day coaching workshop ("Coaching for Impressive CARE") conducted as a leadership development strategy influenced frontline care managers' coaching practices in residential long-term care (LTC) settings. We had four objectives: (a) to identify managers' perceptions of their role as a coach of employee performance in LTC facilities, (b) to understand managers' intentions to coach employee performance, (c) to examine opportunities and factors that contributed to or challenged implementation of workshop coaching skills in daily leadership/management practice, and (d) to examine managers' reports of using coaching practices and employee responses after the workshop. We used an exploratory/descriptive design involving pre-/post-workshop surveys, e-mail reminders, and focus groups to examine participation of 21 LTC managers in a 2-day coaching workshop and their use of coaching practices in the workplace. Focus group findings provided examples of how participants used their coaching skills in practice (e.g., communicating empathy) and how staff responded. Factors contributing to and challenging implementation of these coaching skills in the workplace were identified. Attitudes and intentions to be a coach increased significantly, and some coaching skills were used more frequently after the workshop, specifically planning for performance change with employees. The coaching workshop was feasible to implement, well received by participants, influenced their willingness to become coaches, and had some noted impact on their use of coaching behaviors in the workplace. Coaching skills by managers to improve staff performance with residents in LTC facilities can be learned.

  10. Impact of Audio-Coaching on the Position of Lung Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haasbeek, Cornelis J.A.; Spoelstra, Femke; Lagerwaard, Frank J.

    2008-07-15

    Purpose: Respiration-induced organ motion is a major source of positional, or geometric, uncertainty in thoracic radiotherapy. Interventions to mitigate the impact of motion include audio-coached respiration-gated radiotherapy (RGRT). To assess the impact of coaching on average tumor position during gating, we analyzed four-dimensional computed tomography (4DCT) scans performed both with and without audio-coaching. Methods and Materials: Our RGRT protocol requires that an audio-coached 4DCT scan is performed when the initial free-breathing 4DCT indicates a potential benefit with gating. We retrospectively analyzed 22 such paired scans in patients with well-circumscribed tumors. Changes in lung volume and position of internal target volumesmore » (ITV) generated in three consecutive respiratory phases at both end-inspiration and end-expiration were analyzed. Results: Audio-coaching increased end-inspiration lung volumes by a mean of 10.2% (range, -13% to +43%) when compared with free breathing (p = 0.001). The mean three-dimensional displacement of the center of ITV was 3.6 mm (SD, 2.5; range, 0.3-9.6mm), mainly caused by displacement in the craniocaudal direction. Displacement of ITV caused by coaching was more than 5 mm in 5 patients, all of whom were in the subgroup of 9 patients showing total tumor motion of 10 mm or more during both coached and uncoached breathing. Comparable ITV displacements were observed at end-expiration phases of the 4DCT. Conclusions: Differences in ITV position exceeding 5 mm between coached and uncoached 4DCT scans were detected in up to 56% of mobile tumors. Both end-inspiration and end-expiration RGRT were susceptible to displacements. This indicates that the method of audio-coaching should remain unchanged throughout the course of treatment.« less

  11. Improving the Diagnostic Specificity of CT for Early Detection of Lung Cancer: 4D CT-Based Pulmonary Nodule Elastometry

    DTIC Science & Technology

    2014-08-01

    Our institutional data (all 4D CT scans) are currently stored on DVD’s. Data will be de-archived and suitable lung cancer patients ( patients with...23 lung cancer patients with non-small cell lung cancer (NSCLC) that were treated at our 130 institution. The patient and tumor characteristics are...lung cancer patients to ascertain and treat the most aggressive lesions first. Ultimately it may even be helpful to distinguish aggressiveness of

  12. Analysis of free breathing motion using artifact reduced 4D CT image data

    NASA Astrophysics Data System (ADS)

    Ehrhardt, Jan; Werner, Rene; Frenzel, Thorsten; Lu, Wei; Low, Daniel; Handels, Heinz

    2007-03-01

    The mobility of lung tumors during the respiratory cycle is a source of error in radiotherapy treatment planning. Spatiotemporal CT data sets can be used for studying the motion of lung tumors and inner organs during the breathing cycle. We present methods for the analysis of respiratory motion using 4D CT data in high temporal resolution. An optical flow based reconstruction method was used to generate artifact-reduced 4D CT data sets of lung cancer patients. The reconstructed 4D CT data sets were segmented and the respiratory motion of tumors and inner organs was analyzed. A non-linear registration algorithm is used to calculate the velocity field between consecutive time frames of the 4D data. The resulting velocity field is used to analyze trajectories of landmarks and surface points. By this technique, the maximum displacement of any surface point is calculated, and regions with large respiratory motion are marked. To describe the tumor mobility the motion of the lung tumor center in three orthogonal directions is displayed. Estimated 3D appearance probabilities visualize the movement of the tumor during the respiratory cycle in one static image. Furthermore, correlations between trajectories of the skin surface and the trajectory of the tumor center are determined and skin regions are identified which are suitable for prediction of the internal tumor motion. The results of the motion analysis indicate that the described methods are suitable to gain insight into the spatiotemporal behavior of anatomical and pathological structures during the respiratory cycle.

  13. 78 FR 76711 - Royal City Charter Coach Lines Ltd.-Acquisition of Control-Quick Coach Lines Ltd. d/b/a Quick...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-18

    ... current ownership of Quick, and its wholly owned subsidiary Quick Coach Lines USA Inc. (Quick USA... passengers (MC-205116). Quick USA is a wholly owned subsidiary of Quick. When Royal acquires control of Quick, it will also obtain control of Quick USA. Quick USA is currently inactive and does not provide any...

  14. Dynamic four-dimensional computed tomography (4D CT) imaging for re-entry risk assessment in re-do sternotomy - first experience.

    PubMed

    Narayanan, Harish; Viana, Fabiano F; Smith, Julian A; Roumeliotis, Nicholas K; Troupis, Christopher J; Crossett, Marcus P; Troupis, John M

    2015-10-01

    Repeat cardiac surgeries are well known to have higher rates of complications, one of the important reasons being injuries associated with re-do sternotomy. Routine imaging with CT can help to minimise this risk by pre-operatively assessing the anatomical relation between the sternum and the underlying cardiovascular structures, but is limited by its inability to determine the presence and severity of functional tethering and adhesions between these structures. However, with the evolution of wide area detector MD CT scanners, it is possible to assess the presence of tethering using the dynamic four-dimensional CT (4D CT) imaging technique. Nineteen patients undergoing re-do cardiac surgery were pre-operatively imaged using dynamic 4D CT during regulated respiration. The datasets were assessed in cine mode for presence of differential motion between sternum and underlying cardiovascular structures which indicates lack of significant tethering. Overall, there was excellent correlation between preoperative imaging and intraoperative findings. The technique enabled our surgeons to meticulously plan the procedures and to avoid re-entry related injuries. Our initial experience shows that dynamic 4D CT is useful in risk stratification prior to re-do sternotomy by determining the presence or absence of tethering between sternum and underlying structures based on assessment of differential motion. Furthermore we determined the technique to be superior to non-dynamic assessment of retrocardiac tethering. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  15. SU-E-J-150: Four-Dimensional Cone-Beam CT Algorithm by Extraction of Physical and Motion Parameter of Mobile Targets Retrospective to Image Reconstruction with Motion Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, I; Ahmad, S; Alsbou, N

    Purpose: To develop 4D-cone-beam CT (CBCT) algorithm by motion modeling that extracts actual length, CT numbers level and motion amplitude of a mobile target retrospective to image reconstruction by motion modeling. Methods: The algorithm used three measurable parameters: apparent length and blurred CT number distribution of a mobile target obtained from CBCT images to determine actual length, CT-number value of the stationary target, and motion amplitude. The predictions of this algorithm were tested with mobile targets that with different well-known sizes made from tissue-equivalent gel which was inserted into a thorax phantom. The phantom moved sinusoidally in one-direction to simulatemore » respiratory motion using eight amplitudes ranging 0–20mm. Results: Using this 4D-CBCT algorithm, three unknown parameters were extracted that include: length of the target, CT number level, speed or motion amplitude for the mobile targets retrospective to image reconstruction. The motion algorithms solved for the three unknown parameters using measurable apparent length, CT number level and gradient for a well-defined mobile target obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on the actual target length and motion amplitude. The gradient of the CT number distribution of the mobile target is dependent on the stationary CT number level, actual target length and motion amplitude. Motion frequency and phase did not affect the elongation and CT number distribution of the mobile target and could not be determined. Conclusion: A 4D-CBCT motion algorithm was developed to extract three parameters that include actual length, CT number level and motion amplitude or speed of mobile targets directly from reconstructed CBCT images without prior knowledge of the stationary target parameters. This algorithm provides alternative to 4D-CBCT without requirement to motion tracking and sorting of the images into different breathing phases which has potential applications in diagnostic CT imaging and radiotherapy.« less

  16. Assessing Cardiac Injury in Mice With Dual Energy-MicroCT, 4D-MicroCT, and MicroSPECT Imaging After Partial Heart Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Chang-Lung; Min, Hooney; Befera, Nicholas

    Purpose: To develop a mouse model of cardiac injury after partial heart irradiation (PHI) and to test whether dual energy (DE)-microCT and 4-dimensional (4D)-microCT can be used to assess cardiac injury after PHI to complement myocardial perfusion imaging using micro-single photon emission computed tomography (SPECT). Methods and Materials: To study cardiac injury from tangent field irradiation in mice, we used a small-field biological irradiator to deliver a single dose of 12 Gy x-rays to approximately one-third of the left ventricle (LV) of Tie2Cre; p53{sup FL/+} and Tie2Cre; p53{sup FL/−} mice, where 1 or both alleles of p53 are deleted in endothelialmore » cells. Four and 8 weeks after irradiation, mice were injected with gold and iodinated nanoparticle-based contrast agents, and imaged with DE-microCT and 4D-microCT to evaluate myocardial vascular permeability and cardiac function, respectively. Additionally, the same mice were imaged with microSPECT to assess myocardial perfusion. Results: After PHI with tangent fields, DE-microCT scans showed a time-dependent increase in accumulation of gold nanoparticles (AuNp) in the myocardium of Tie2Cre; p53{sup FL/−} mice. In Tie2Cre; p53{sup FL/−} mice, extravasation of AuNp was observed within the irradiated LV, whereas in the myocardium of Tie2Cre; p53{sup FL/+} mice, AuNp were restricted to blood vessels. In addition, data from DE-microCT and microSPECT showed a linear correlation (R{sup 2} = 0.97) between the fraction of the LV that accumulated AuNp and the fraction of LV with a perfusion defect. Furthermore, 4D-microCT scans demonstrated that PHI caused a markedly decreased ejection fraction, and higher end-diastolic and end-systolic volumes, to develop in Tie2Cre; p53{sup FL/−} mice, which were associated with compensatory cardiac hypertrophy of the heart that was not irradiated. Conclusions: Our results show that DE-microCT and 4D-microCT with nanoparticle-based contrast agents are novel imaging approaches complementary to microSPECT for noninvasive assessment of the change in myocardial vascular permeability and cardiac function of mice in whom myocardial injury develops after PHI.« less

  17. SU-E-J-123: Assessing Segmentation Accuracy of Internal Volumes and Sub-Volumes in 4D PET/CT of Lung Tumors Using a Novel 3D Printed Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soultan, D; Murphy, J; James, C

    2015-06-15

    Purpose: To assess the accuracy of internal target volume (ITV) segmentation of lung tumors for treatment planning of simultaneous integrated boost (SIB) radiotherapy as seen in 4D PET/CT images, using a novel 3D-printed phantom. Methods: The insert mimics high PET tracer uptake in the core and 50% uptake in the periphery, by using a porous design at the periphery. A lung phantom with the insert was placed on a programmable moving platform. Seven breathing waveforms of ideal and patient-specific respiratory motion patterns were fed to the platform, and 4D PET/CT scans were acquired of each of them. CT images weremore » binned into 10 phases, and PET images were binned into 5 phases following the clinical protocol. Two scenarios were investigated for segmentation: a gate 30–70 window, and no gating. The radiation oncologist contoured the outer ITV of the porous insert with on CT images, while the internal void volume with 100% uptake was contoured on PET images for being indistinguishable from the outer volume in CT images. Segmented ITVs were compared to the expected volumes based on known target size and motion. Results: 3 ideal breathing patterns, 2 regular-breathing patient waveforms, and 2 irregular-breathing patient waveforms were used for this study. 18F-FDG was used as the PET tracer. The segmented ITVs from CT closely matched the expected motion for both no gating and gate 30–70 window, with disagreement of contoured ITV with respect to the expected volume not exceeding 13%. PET contours were seen to overestimate volumes in all the cases, up to more than 40%. Conclusion: 4DPET images of a novel 3D printed phantom designed to mimic different uptake values were obtained. 4DPET contours overestimated ITV volumes in all cases, while 4DCT contours matched expected ITV volume values. Investigation of the cause and effects of the discrepancies is undergoing.« less

  18. Assessing the Impact of ADHD Coaching Services on University Students' Learning Skills, Self-Regulation, and Well-Being

    ERIC Educational Resources Information Center

    Field, Sharon; Parker, David R.; Sawilowsky, Shlomo; Rolands, Laura

    2013-01-01

    The effects of coaching on learning and study skills, self-regulation, and subjective well-being of students with ADHD attending 2- and 4-year colleges or universities was examined. Students were randomly assigned to participate in coaching or comparison groups. Coaching students received weekly phone-based coaching sessions and additional…

  19. SU-C-BRB-06: Utilizing 3D Scanner and Printer for Dummy Eye-Shield: Artifact-Free CT Images of Tungsten Eye-Shield for Accurate Dose Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J; Lee, J; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul

    Purpose: To evaluate the effect of a tungsten eye-shield on the dose distribution of a patient. Methods: A 3D scanner was used to extract the dimension and shape of a tungsten eye-shield in the STL format. Scanned data was transferred into a 3D printer. A dummy eye shield was then produced using bio-resin (3D systems, VisiJet M3 Proplast). For a patient with mucinous carcinoma, the planning CT was obtained with the dummy eye-shield placed on the patient’s right eye. Field shaping of 6 MeV was performed using a patient-specific cerrobend block on the 15 x 15 cm{sup 2} applicator. Themore » gantry angle was 330° to cover the planning target volume near by the lens. EGS4/BEAMnrc was commissioned from our measurement data from a Varian 21EX. For the CT-based dose calculation using EGS4/DOSXYZnrc, the CT images were converted to a phantom file through the ctcreate program. The phantom file had the same resolution as the planning CT images. By assigning the CT numbers of the dummy eye-shield region to 17000, the real dose distributions below the tungsten eye-shield were calculated in EGS4/DOSXYZnrc. In the TPS, the CT number of the dummy eye-shield region was assigned to the maximum allowable CT number (3000). Results: As compared to the maximum dose, the MC dose on the right lens or below the eye shield area was less than 2%, while the corresponding RTP calculated dose was an unrealistic value of approximately 50%. Conclusion: Utilizing a 3D scanner and a 3D printer, a dummy eye-shield for electron treatment can be easily produced. The artifact-free CT images were successfully incorporated into the CT-based Monte Carlo simulations. The developed method was useful in predicting the realistic dose distributions around the lens blocked with the tungsten shield.« less

  20. Evaluation of Cassia tora Linn. against Oxidative Stress-induced DNA and Cell Membrane Damage

    PubMed Central

    Kumar, R Sunil; Narasingappa, Ramesh Balenahalli; Joshi, Chandrashekar G; Girish, Talakatta K; Prasada Rao, Ummiti JS; Danagoudar, Ananda

    2017-01-01

    Objective: The present study aims to evaluate antioxidants and protective role of Cassia tora Linn. against oxidative stress-induced DNA and cell membrane damage. Materials and Methods: The total and profiles of flavonoids were identified and quantified through reversed-phase high-performance liquid chromatography. In vitro antioxidant activity was determined using standard antioxidant assays. The protective role of C. tora extracts against oxidative stress-induced DNA and cell membrane damage was examined by electrophoretic and scanning electron microscopic studies, respectively. Results: The total flavonoid content of CtEA was 106.8 ± 2.8 mg/g d.w.QE, CtME was 72.4 ± 1.12 mg/g d.w.QE, and CtWE was 30.4 ± 0.8 mg/g d.w.QE. The concentration of flavonoids present in CtEA in decreasing order: quercetin >kaempferol >epicatechin; in CtME: quercetin >rutin >kaempferol; whereas, in CtWE: quercetin >rutin >kaempferol. The CtEA inhibited free radical-induced red blood cell hemolysis and cell membrane morphology better than CtME as confirmed by a scanning electron micrograph. CtEA also showed better protection than CtME and CtWE against free radical-induced DNA damage as confirmed by electrophoresis. Conclusion: C. tora contains flavonoids and inhibits oxidative stress and can be used for many health benefits and pharmacotherapy. PMID:28584491

  1. Improved CT-based estimate of pulmonary gas trapping accounting for scanner and lung-volume variations in a multicenter asthmatic study.

    PubMed

    Choi, Sanghun; Hoffman, Eric A; Wenzel, Sally E; Castro, Mario; Lin, Ching-Long

    2014-09-15

    Lung air trapping is estimated via quantitative computed tomography (CT) using density threshold-based measures on an expiration scan. However, the effects of scanner differences and imaging protocol adherence on quantitative assessment are known to be problematic. This study investigates the effects of protocol differences, such as using different CT scanners and breath-hold coaches in a multicenter asthmatic study, and proposes new methods that can adjust intersite and intersubject variations. CT images of 50 healthy subjects and 42 nonsevere and 52 severe asthmatics at total lung capacity (TLC) and functional residual capacity (FRC) were acquired using three different scanners and two different coaching methods at three institutions. A fraction threshold-based approach based on the corrected Hounsfield unit of air with tracheal density was applied to quantify air trapping at FRC. The new air-trapping method was enhanced by adding a lung-shaped metric at TLC and the lobar ratio of air-volume change between TLC and FRC. The fraction-based air-trapping method is able to collapse air-trapping data of respective populations into distinct regression lines. Relative to a constant value-based clustering scheme, the slope-based clustering scheme shows the improved performance and reduced misclassification rate of healthy subjects. Furthermore, both lung shape and air-volume change are found to be discriminant variables for differentiating among three populations of healthy subjects and nonsevere and severe asthmatics. In conjunction with the lung shape and air-volume change, the fraction-based measure of air trapping enables differentiation of severe asthmatics from nonsevere asthmatics and nonsevere asthmatics from healthy subjects, critical for the development and evaluation of new therapeutic interventions. Copyright © 2014 the American Physiological Society.

  2. Improved CT-based estimate of pulmonary gas trapping accounting for scanner and lung-volume variations in a multicenter asthmatic study

    PubMed Central

    Choi, Sanghun; Hoffman, Eric A.; Wenzel, Sally E.; Castro, Mario

    2014-01-01

    Lung air trapping is estimated via quantitative computed tomography (CT) using density threshold-based measures on an expiration scan. However, the effects of scanner differences and imaging protocol adherence on quantitative assessment are known to be problematic. This study investigates the effects of protocol differences, such as using different CT scanners and breath-hold coaches in a multicenter asthmatic study, and proposes new methods that can adjust intersite and intersubject variations. CT images of 50 healthy subjects and 42 nonsevere and 52 severe asthmatics at total lung capacity (TLC) and functional residual capacity (FRC) were acquired using three different scanners and two different coaching methods at three institutions. A fraction threshold-based approach based on the corrected Hounsfield unit of air with tracheal density was applied to quantify air trapping at FRC. The new air-trapping method was enhanced by adding a lung-shaped metric at TLC and the lobar ratio of air-volume change between TLC and FRC. The fraction-based air-trapping method is able to collapse air-trapping data of respective populations into distinct regression lines. Relative to a constant value-based clustering scheme, the slope-based clustering scheme shows the improved performance and reduced misclassification rate of healthy subjects. Furthermore, both lung shape and air-volume change are found to be discriminant variables for differentiating among three populations of healthy subjects and nonsevere and severe asthmatics. In conjunction with the lung shape and air-volume change, the fraction-based measure of air trapping enables differentiation of severe asthmatics from nonsevere asthmatics and nonsevere asthmatics from healthy subjects, critical for the development and evaluation of new therapeutic interventions. PMID:25103972

  3. A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Hao; Folkerts, Michael; Jiang, Steve B., E-mail: xun.jia@utsouthwestern.edu, E-mail: steve.jiang@UTSouthwestern.edu

    2014-07-15

    Purpose: 4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. Methods: The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is inventedmore » to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. Results: The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3–0.5 mm for patients 1–3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1–1.5 min per phase. Conclusions: High-quality 4D-CBCT imaging based on the clinically standard 1-min 3D CBCT scanning protocol is feasible via the proposed hybrid reconstruction algorithm.« less

  4. TU-F-CAMPUS-J-03: Evaluation of a New GE Device-Less Cine 4D-CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, R; Pan, T; Chandler, A

    2015-06-15

    Purpose: Standard cine 4D-CT (S-4DCT) is the cine CT scan of the thorax followed by image sorting with the respiratory signal recorded by the RPM. Although the feasibility of cine 4D-CT without RPM or device-less 4DCT (DL-4DCT) has been reported in a laboratory setting, the only commercial implementation of DL-4DCT was made recently by GE based on the measurements of the lung, body and air area and density. We report the initial results of this new DL-4DCT on its determination of gross tumor volume (GTV). Methods: 30 stereotactic body radiation therapy (SBRT) patients with NSCLC were included in the study.more » All patients received the S-4DCT for their treatment planning. Their cine CT data without the respiratory signal from RPM were submitted to the DL-4DCT. The DL-4DCT image quality was assessed in reference to S-4DCT. Using maximum intensity projection (MIP) images, the GTVs of the S-4DCT and DL-4DCT were compared on a subset of 9 patients whose tumors in the low density lung regions could be contoured using a region growing algorithm in MIM without contouring bias from the user. A lower threshold of −424 HU was used for all patients and other algorithm parameters were held constant for each patient. Results: The DL-4DCT was able to produce the 4DCT images on 29 out of the 30 SBRT cases. One case failed due to the enhanced calcification surrounding both the breast implants. The GTVs determined on the 9 patients with DL-4DCT were 4.2 ± 4.8% smaller than the GTVs with S-4DCT. However, this was statistically insignificant (p=0.15). The Dice similarity coefficients were 95.1 ± 1.8%. The image quality of DL-4DCT and S-4DCT was similar on the 29 cases. Conclusion: The first commercial DL-4DCT was promising in generating 4D-CT images without a respiratory monitoring device in this preliminary study of 30 patients.« less

  5. Distribution of Chlamydia trachomatis serotypes in clinical urogenital samples from north-eastern Croatia.

    PubMed

    Bošnjak, Zinka; Džijan, Snježana; Pavlinić, Dinko; Perić, Magdalena; Ružman, Nataša; Križan, Ivana Roksandić; Lauc, Gordan; Antolović-Požgain, Arlen; Burazin, Jelena; Vuković, Dubravka

    2012-06-01

    The purpose of this study was to determine prevalence of Chlamydia trachomatis (Ct) urogenital infection and its serotype distribution from clinical samples in north-eastern Croatia. During a 3-year period, 2,379 urogenital samples were analyzed by real-time polymerase chain reaction (A group), while 4,846 genital swabs were analyzed by direct fluorescent antibody test (B group). 132 Ct positive specimens were genotyped by omp1 gene sequencing. The prevalence rate of Ct was 3.2 % in A and 1 % in B group. The most prevalent chlamydial genotype was E (44 %), followed by F (33 %), K (11.5 %), G (8 %), J/UW (5.3 %), D-IC (4.4 %), D-B120 (1.8 %), and B/IU, J/IU, Ia/IU (0.9 % each) serotypes. Single-nucleotide polymorphisms (SNPs) of omp1 gene were detected in E, K, and G serotypes. Some of these SNPs (C/T at position 272 and G/A at position 813 in E strain; C/T at position 884 in D strain) might represent novel omp1 variants.

  6. Comparative 3D micro-CT and 2D histomorphometry analysis of dental implant osseointegration in the maxilla of minipigs.

    PubMed

    Bissinger, Oliver; Probst, Florian Andreas; Wolff, Klaus-Dietrich; Jeschke, Anke; Weitz, Jochen; Deppe, Herbert; Kolk, Andreas

    2017-04-01

    The bone implant contact (BIC) has traditionally been evaluated with histological methods. Thereupon, strong correlations of two-dimensional (2D) BIC have been detected between μCT and destructive histology. However, due to the high intra-sample variability in BIC values, one histological slice is not sufficient to represent 3D BIC. Therefore, our aim has been to correlate the averaged values of 3-4 histological sections to 3D μCT. Fifty-four implants inserted into the maxilla of 14 minipigs were evaluated. Two different time points were selected to assess the 3D BIC (distance to implant: 2-5 voxels), an inner ring (6-30 voxels) and an outer ring (55-100 voxels) using μCT (voxel size: 10 μm) and to correlate the values to histomorphometry. Strong correlations (p < 0.0001; 28 days, 56 days, total) were seen between μCT and histomorphometry concerning BIC (r = 0.84, r = 0.85, r = 0.83), the inner ring (r = 0.87, r = 0.87, r = 0.88) and the outer ring (r = 0.85, r = 0.85, r = 0.88). Closer to the implant, μCT values were higher compared with histomorphometry. Although 3-4 histological slices per implant seem to predict the 3D BIC, μCT might be advantageous because of its non-destructive 3D character. The healing time may not impact on the comparability. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. [The third dimension tomography versus cranial X-ray cephalometry to predict maxilla advance by distraction in hypoplastic maxilla].

    PubMed

    Rosas-Muñoz, Arturo; Soriano-Padilla, Fernando; Rendón-Macías, Mario Enrique

    2010-01-01

    the osteogenic distraction is the treatment for the correction of the hypoplastic maxilla secondary to the repair of a cleft lip-palate. Its planning is based on articulated models. Our objective was to describe the accuracy of three-dimensional Cephalometry (CT3D) for projecting jaw displacement. three patients with hypoplastic maxilla. Interventions estimation of the advance required of lateral maxilla through Cephalometry of skull (CLC), CT3D and an articulated model (gold standard). Two months after distraction finalized the advance predicted was compared. the error of the advance projection in each patient was smaller with the CT3D versus CLC (+1, +1 and +1 mm versus -10, -14 and -9mm). Corrections post-distraction were of +25 %, +26 % and +38.4 % on the programmed one. CT3D predicted better the correction (+19 %, +10.8 %, +33.4 % versus CLC: -50 %; -60.8 % and -34.6 %). Chewing alterations were not seen in any patient. the planning of the necessary advance for distraction in patients with hypoplastic maxilla by CT3D can shorten the time of studies and should be consider as next to the projection of articulated model.

  8. Time-resolved computed tomography of the liver: retrospective, multi-phase image reconstruction derived from volumetric perfusion imaging.

    PubMed

    Fischer, Michael A; Leidner, Bertil; Kartalis, Nikolaos; Svensson, Anders; Aspelin, Peter; Albiin, Nils; Brismar, Torkel B

    2014-01-01

    To assess feasibility and image quality (IQ) of a new post-processing algorithm for retrospective extraction of an optimised multi-phase CT (time-resolved CT) of the liver from volumetric perfusion imaging. Sixteen patients underwent clinically indicated perfusion CT using 4D spiral mode of dual-source 128-slice CT. Three image sets were reconstructed: motion-corrected and noise-reduced (MCNR) images derived from 4D raw data; maximum and average intensity projections (time MIP/AVG) of the arterial/portal/portal-venous phases and all phases (total MIP/ AVG) derived from retrospective fusion of dedicated MCNR split series. Two readers assessed the IQ, detection rate and evaluation time; one reader assessed image noise and lesion-to-liver contrast. Time-resolved CT was feasible in all patients. Each post-processing step yielded a significant reduction of image noise and evaluation time, maintaining lesion-to-liver contrast. Time MIPs/AVGs showed the highest overall IQ without relevant motion artefacts and best depiction of arterial and portal/portal-venous phases respectively. Time MIPs demonstrated a significantly higher detection rate for arterialised liver lesions than total MIPs/AVGs and the raw data series. Time-resolved CT allows data from volumetric perfusion imaging to be condensed into an optimised multi-phase liver CT, yielding a superior IQ and higher detection rate for arterialised liver lesions than the raw data series. • Four-dimensional computed tomography is limited by motion artefacts and poor image quality. • Time-resolved-CT facilitates 4D-CT data visualisation, segmentation and analysis by condensing raw data. • Time-resolved CT demonstrates better image quality than raw data images. • Time-resolved CT improves detection of arterialised liver lesions in cirrhotic patients.

  9. 14 CFR 399.31 - Standard industry fare level.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Standard industry fare level. 399.31... Standard industry fare level. (a) Generally. Except as set forth in paragraph (d) of this section, the standard industry fare level (“SIFL”) for coach/standard service in a market is equal to the predominant...

  10. 14 CFR 399.31 - Standard industry fare level.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Standard industry fare level. 399.31... Standard industry fare level. (a) Generally. Except as set forth in paragraph (d) of this section, the standard industry fare level (“SIFL”) for coach/standard service in a market is equal to the predominant...

  11. 14 CFR 399.31 - Standard industry fare level.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Standard industry fare level. 399.31... Standard industry fare level. (a) Generally. Except as set forth in paragraph (d) of this section, the standard industry fare level (“SIFL”) for coach/standard service in a market is equal to the predominant...

  12. 14 CFR 399.31 - Standard industry fare level.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Standard industry fare level. 399.31... Standard industry fare level. (a) Generally. Except as set forth in paragraph (d) of this section, the standard industry fare level (“SIFL”) for coach/standard service in a market is equal to the predominant...

  13. 14 CFR 399.31 - Standard industry fare level.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Standard industry fare level. 399.31... Standard industry fare level. (a) Generally. Except as set forth in paragraph (d) of this section, the standard industry fare level (“SIFL”) for coach/standard service in a market is equal to the predominant...

  14. Artery and vein segmentation of the cerebral vasculature in 4D CT using a 3D fully convolutional neural network

    NASA Astrophysics Data System (ADS)

    Meijs, Midas; Manniesing, Rashindra

    2018-02-01

    Segmentation of the arteries and veins of the cerebral vasculature is important for improved visualization and for the detection of vascular related pathologies including arteriovenous malformations. We propose a 3D fully convolutional neural network (CNN) using a time-to-signal image as input and the distance to the center of gravity of the brain as spatial feature integrated in the final layers of the CNN. The method was trained and validated on 6 and tested on 4 4D CT patient imaging data. The reference standard was acquired by manual annotations by an experienced observer. Quantitative evaluation showed a mean Dice similarity coefficient of 0.94 +/- 0.03 and 0.97 +/- 0.01, a mean absolute volume difference of 4.36 +/- 5.47 % and 1.79 +/- 2.26 % for artery and vein respectively and an overall accuracy of 0.96 +/- 0.02. The average calculation time per volume on the test set was approximately one minute. Our method shows promising results and enables fast and accurate segmentation of arteries and veins in full 4D CT imaging data.

  15. The retrospective binning method improves the consistency of phase binning in respiratory-gated PET/CT

    NASA Astrophysics Data System (ADS)

    Didierlaurent, D.; Ribes, S.; Batatia, H.; Jaudet, C.; Dierickx, L. O.; Zerdoud, S.; Brillouet, S.; Caselles, O.; Courbon, F.

    2012-12-01

    This study assesses the accuracy of prospective phase-gated PET/CT data binning and presents a retrospective data binning method that improves image quality and consistency. Respiratory signals from 17 patients who underwent 4D PET/CT were analysed to evaluate the reproducibility of temporal triggers used for the standard phase-based gating method. Breathing signals were reprocessed to implement retrospective PET data binning. The mean and standard deviation of time lags between automatic triggers provided by the Real-time Position Management (RPM, Varian) gating device and inhalation peaks derived from respiratory curves were computed for each patient. The total number of respiratory cycles available for 4D PET/CT according to the binning mode (prospective versus retrospective) was compared. The maximum standardized uptake value (SUVmax), biological tumour volume (BTV) and tumour trajectory measures were determined from the PET/CT images of five patients. Compared to retrospective binning (RB), prospective gating approach led to (i) a significant loss in breathing cycles (15%) and (ii) the inconsistency of data binning due to temporal dispersion of triggers (average 396 ms). Consequently, tumour characterization could be impacted. In retrospective mode, SUVmax was up to 27% higher, where no significant difference appeared in BTV. In addition, prospective mode gave an inconsistent spatial location of the tumour throughout the bins. Improved consistency with breathing patterns and greater motion amplitude of the tumour centroid were observed with retrospective mode. The detection of the tumour motion and trajectory was improved also for small temporal dispersion of triggers. This study shows that the binning mode could have a significant impact on 4D PET images. The consistency of triggers with breathing signals should be checked before clinical use of gated PET/CT images, and our RB method improves 4D PET/CT image quantification.

  16. Myogenin, MyoD, and myosin expression after pharmacologically and surgically induced hypertrophy

    NASA Technical Reports Server (NTRS)

    Mozdziak, P. E.; Greaser, M. L.; Schultz, E.

    1998-01-01

    The relationship between myogenin or MyoD expression and hypertrophy of the rat soleus produced either by clenbuterol and 3,3', 5-triiodo-L-thyronine (CT) treatment or by surgical overload was examined. Mature female rats were subjected to surgical overload of the right soleus with the left soleus serving as a control. Another group received the same surgical treatment but were administered CT. Soleus muscles were harvested 4 wk after surgical overload and weighed. Myosin heavy chain isoforms were separated by using polyacrylamide gel electrophoresis while myogenin and MyoD expression were evaluated by Northern analysis. CT and functional overload increased soleus muscle weight. CT treatment induced the appearance of the fast type IIX myosin heavy chain isoform, depressed myogenin expression, and induced MyoD expression. However, functional overload did not alter myogenin or MyoD expression in CT-treated or non-CT-treated rats. Thus pharmacologically and surgically induced hypertrophy have differing effects on myogenin and MyoD expression, because their levels were associated with changes in myosin heavy chain composition (especially type IIX) rather than changes in muscle mass.

  17. A Novel Fast Helical 4D-CT Acquisition Technique to Generate Low-Noise Sorting Artifact–Free Images at User-Selected Breathing Phases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, David, E-mail: dhthomas@mednet.ucla.edu; Lamb, James; White, Benjamin

    2014-05-01

    Purpose: To develop a novel 4-dimensional computed tomography (4D-CT) technique that exploits standard fast helical acquisition, a simultaneous breathing surrogate measurement, deformable image registration, and a breathing motion model to remove sorting artifacts. Methods and Materials: Ten patients were imaged under free-breathing conditions 25 successive times in alternating directions with a 64-slice CT scanner using a low-dose fast helical protocol. An abdominal bellows was used as a breathing surrogate. Deformable registration was used to register the first image (defined as the reference image) to the subsequent 24 segmented images. Voxel-specific motion model parameters were determined using a breathing motion model. Themore » tissue locations predicted by the motion model in the 25 images were compared against the deformably registered tissue locations, allowing a model prediction error to be evaluated. A low-noise image was created by averaging the 25 images deformed to the first image geometry, reducing statistical image noise by a factor of 5. The motion model was used to deform the low-noise reference image to any user-selected breathing phase. A voxel-specific correction was applied to correct the Hounsfield units for lung parenchyma density as a function of lung air filling. Results: Images produced using the model at user-selected breathing phases did not suffer from sorting artifacts common to conventional 4D-CT protocols. The mean prediction error across all patients between the breathing motion model predictions and the measured lung tissue positions was determined to be 1.19 ± 0.37 mm. Conclusions: The proposed technique can be used as a clinical 4D-CT technique. It is robust in the presence of irregular breathing and allows the entire imaging dose to contribute to the resulting image quality, providing sorting artifact–free images at a patient dose similar to or less than current 4D-CT techniques.« less

  18. A novel fast helical 4D-CT acquisition technique to generate low-noise sorting artifact-free images at user-selected breathing phases.

    PubMed

    Thomas, David; Lamb, James; White, Benjamin; Jani, Shyam; Gaudio, Sergio; Lee, Percy; Ruan, Dan; McNitt-Gray, Michael; Low, Daniel

    2014-05-01

    To develop a novel 4-dimensional computed tomography (4D-CT) technique that exploits standard fast helical acquisition, a simultaneous breathing surrogate measurement, deformable image registration, and a breathing motion model to remove sorting artifacts. Ten patients were imaged under free-breathing conditions 25 successive times in alternating directions with a 64-slice CT scanner using a low-dose fast helical protocol. An abdominal bellows was used as a breathing surrogate. Deformable registration was used to register the first image (defined as the reference image) to the subsequent 24 segmented images. Voxel-specific motion model parameters were determined using a breathing motion model. The tissue locations predicted by the motion model in the 25 images were compared against the deformably registered tissue locations, allowing a model prediction error to be evaluated. A low-noise image was created by averaging the 25 images deformed to the first image geometry, reducing statistical image noise by a factor of 5. The motion model was used to deform the low-noise reference image to any user-selected breathing phase. A voxel-specific correction was applied to correct the Hounsfield units for lung parenchyma density as a function of lung air filling. Images produced using the model at user-selected breathing phases did not suffer from sorting artifacts common to conventional 4D-CT protocols. The mean prediction error across all patients between the breathing motion model predictions and the measured lung tissue positions was determined to be 1.19 ± 0.37 mm. The proposed technique can be used as a clinical 4D-CT technique. It is robust in the presence of irregular breathing and allows the entire imaging dose to contribute to the resulting image quality, providing sorting artifact-free images at a patient dose similar to or less than current 4D-CT techniques. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. A Collaborative Professional Development Initiative Supporting Early Literacy Coaches

    ERIC Educational Resources Information Center

    Mraz, Maryann; Kissel, Brian; Algozzine, Bob; Babb, Julie; Foxworth, Kimberly

    2011-01-01

    Many believe that the key to translating research into successful practice lies in providing teachers with continuous professional development and ongoing coaching support. In this article, we provide an overview of the relevant coaching literature and describe 4 critical features of an evidence-based preschool literacy coaching model: the coach…

  20. Assessment of the feasibility of using transrectal ultrasound for postimplant dosimetry in low-dose-rate prostate brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davies, Rhian Siân, E-mail: rhian.s.davies@wales.nhs.uk; Perrett, Teresa; Powell, Jane

    A study was performed to establish whether transrectal ultrasound (TRUS)-based postimplant dosimetry (PID) is both practically feasible and comparable to computed tomography (CT)-based PID, recommended in current published guidelines. In total, 22 patients treated consecutively at a single cancer center with low-dose-rate (LDR) brachytherapy for early-stage prostate cancer had a transrectal ultrasound performed immediately after implant (d0-TRUS) and computed tomography scan 30 days after implant (d30-CT). Postimplant dosimetry planning was performed on both image sets and the results were compared. The interobserver reproducibility of the transrectal ultrasound postimplant dosimetry planning technique was also assessed. It was noticed that there wasmore » no significant difference in mean prostate D{sub 90} (136.5 Gy and 144.4 Gy, p = 0.2197), V{sub 100} (86.4% and 89.1%, p = 0.1480) and V{sub 150} (52.0% and 47.8%, p = 0.1657) for d30-CT and d0-TRUS, respectively. Rectal doses were significantly higher for d0-TRUS than d30-CT. Urethral doses were available with d0-TRUS only. We have shown that d0-TRUS PID is a useful tool for assessing the quality of an implant after low-dose-rate prostate brachytherapy and is comparable to d30-CT PID. There are clear advantages to its use in terms of resource and time efficiency both for the clinical team and the patient.« less

  1. SU-E-T-222: Computational Optimization of Monte Carlo Simulation On 4D Treatment Planning Using the Cloud Computing Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chow, J

    Purpose: This study evaluated the efficiency of 4D lung radiation treatment planning using Monte Carlo simulation on the cloud. The EGSnrc Monte Carlo code was used in dose calculation on the 4D-CT image set. Methods: 4D lung radiation treatment plan was created by the DOSCTP linked to the cloud, based on the Amazon elastic compute cloud platform. Dose calculation was carried out by Monte Carlo simulation on the 4D-CT image set on the cloud, and results were sent to the FFD4D image deformation program for dose reconstruction. The dependence of computing time for treatment plan on the number of computemore » node was optimized with variations of the number of CT image set in the breathing cycle and dose reconstruction time of the FFD4D. Results: It is found that the dependence of computing time on the number of compute node was affected by the diminishing return of the number of node used in Monte Carlo simulation. Moreover, the performance of the 4D treatment planning could be optimized by using smaller than 10 compute nodes on the cloud. The effects of the number of image set and dose reconstruction time on the dependence of computing time on the number of node were not significant, as more than 15 compute nodes were used in Monte Carlo simulations. Conclusion: The issue of long computing time in 4D treatment plan, requiring Monte Carlo dose calculations in all CT image sets in the breathing cycle, can be solved using the cloud computing technology. It is concluded that the optimized number of compute node selected in simulation should be between 5 and 15, as the dependence of computing time on the number of node is significant.« less

  2. Peer Coaching Through mHealth Targeting Physical Activity in People With Parkinson Disease: Feasibility Study.

    PubMed

    Colón-Semenza, Cristina; Latham, Nancy K; Quintiliani, Lisa M; Ellis, Terry D

    2018-02-15

    Long-term engagement in exercise and physical activity mitigates the progression of disability and increases quality of life in people with Parkinson disease (PD). Despite this, the vast majority of individuals with PD are sedentary. There is a critical need for a feasible, safe, acceptable, and effective method to assist those with PD to engage in active lifestyles. Peer coaching through mobile health (mHealth) may be a viable approach. The purpose of this study was to develop a PD-specific peer coach training program and a remote peer-mentored walking program using mHealth technology with the goal of increasing physical activity in persons with PD. We set out to examine the feasibility, safety, and acceptability of the programs along with preliminary evidence of individual-level changes in walking activity, self-efficacy, and disability in the peer mentees. A peer coach training program and a remote peer-mentored walking program using mHealth was developed and tested in 10 individuals with PD. We matched physically active persons with PD (peer coaches) with sedentary persons with PD (peer mentees), resulting in 5 dyads. Using both Web-based and in-person delivery methods, we trained the peer coaches in basic knowledge of PD, exercise, active listening, and motivational interviewing. Peer coaches and mentees wore FitBit Zip activity trackers and participated in daily walking over 8 weeks. Peer dyads interacted daily via the FitBit friends mobile app and weekly via telephone calls. Feasibility was determined by examining recruitment, participation, and retention rates. Safety was assessed by monitoring adverse events during the study period. Acceptability was assessed via satisfaction surveys. Individual-level changes in physical activity were examined relative to clinically important differences. Four out of the 5 peer pairs used the FitBit activity tracker and friends function without difficulty. A total of 4 of the 5 pairs completed the 8 weekly phone conversations. There were no adverse events over the course of the study. All peer coaches were "satisfied" or "very satisfied" with the training program, and all participants were "satisfied" or "very satisfied" with the peer-mentored walking program. All participants would recommend this program to others with PD. Increases in average steps per day exceeding the clinically important difference occurred in 4 out of the 5 mentees. Remote peer coaching using mHealth is feasible, safe, and acceptable for persons with PD. Peer coaching using mHealth technology may be a viable method to increase physical activity in individuals with PD. Larger controlled trials are necessary to examine the effectiveness of this approach. ©Cristina Colón-Semenza, Nancy K Latham, Lisa M Quintiliani, Terry D Ellis. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 15.02.2018.

  3. Estimation of lung tumor position from multiple anatomical features on 4D-CT using multiple regression analysis.

    PubMed

    Ono, Tomohiro; Nakamura, Mitsuhiro; Hirose, Yoshinori; Kitsuda, Kenji; Ono, Yuka; Ishigaki, Takashi; Hiraoka, Masahiro

    2017-09-01

    To estimate the lung tumor position from multiple anatomical features on four-dimensional computed tomography (4D-CT) data sets using single regression analysis (SRA) and multiple regression analysis (MRA) approach and evaluate an impact of the approach on internal target volume (ITV) for stereotactic body radiotherapy (SBRT) of the lung. Eleven consecutive lung cancer patients (12 cases) underwent 4D-CT scanning. The three-dimensional (3D) lung tumor motion exceeded 5 mm. The 3D tumor position and anatomical features, including lung volume, diaphragm, abdominal wall, and chest wall positions, were measured on 4D-CT images. The tumor position was estimated by SRA using each anatomical feature and MRA using all anatomical features. The difference between the actual and estimated tumor positions was defined as the root-mean-square error (RMSE). A standard partial regression coefficient for the MRA was evaluated. The 3D lung tumor position showed a high correlation with the lung volume (R = 0.92 ± 0.10). Additionally, ITVs derived from SRA and MRA approaches were compared with ITV derived from contouring gross tumor volumes on all 10 phases of the 4D-CT (conventional ITV). The RMSE of the SRA was within 3.7 mm in all directions. Also, the RMSE of the MRA was within 1.6 mm in all directions. The standard partial regression coefficient for the lung volume was the largest and had the most influence on the estimated tumor position. Compared with conventional ITV, average percentage decrease of ITV were 31.9% and 38.3% using SRA and MRA approaches, respectively. The estimation accuracy of lung tumor position was improved by the MRA approach, which provided smaller ITV than conventional ITV. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  4. The transfer of skill from short tennis to lawn tennis.

    PubMed

    Coldwells, A; Hare, M E

    1994-01-01

    The purpose of this study was to establish if short tennis skills transferred to lawn tennis. The experiment was conducted in two parts. In the first experiment 16 children (average age 8.9 years) were coached for 20 h (2 h/day for 2 weeks). The experimental group (n = 8) received 10 h of short tennis coaching followed by 10h of tennis coaching. The control group (n = 8) received tennis coaching only. In the second experiment 14 children (average age 8.5 years) were coached for 8h in group strokes alone (only ground strokes were tested and analysed). The experimental group (n = 7) received 4h of short tennis coaching and 4h of tennis coaching; the control group (n = 7) received tennis coaching only. Prior to coaching, all children were tested on the Dyer Backboard Test. The tests were video-taped for later analysis of technique. The video was analysed by three coaches in terms of backswing, positioning (position where player stood in reference to the bounce of the ball), follow-through, and placement (accuracy with which the ball was hit). The experimental group improved more than the control group on the Dyer Backboard Test (p < 0.05) in Experiment 1. In Experiment 2 both groups improved (p < 0.05) with coaching; there was no difference (p > 0.05) between the two groups following coaching. This implied that the short tennis skills positively transferred to tennis.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Practice Makes Perfect? The Impact of Coaching and Moral Stories on Children's Lie-Telling

    ERIC Educational Resources Information Center

    Talwar, Victoria; Yachison, Sarah; Leduc, Karissa; Nagar, Pooja Megha

    2018-01-01

    Children (n = 202; 4 to 7 years old) witnessed a confederate break a toy and were asked to keep the transgression a secret. Children were randomly assigned to a Coaching condition (i.e., No Coaching, Light Coaching, or Heavy Coaching) and a Moral Story condition (i.e., Positive or Neutral). Overall, 89.7% of children lied about the broken toy when…

  6. The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization

    NASA Astrophysics Data System (ADS)

    Norris, Hannah; Zhang, Yakun; Frush, Jack; Sturgeon, Gregory M.; Minhas, Anum; Tward, Daniel J.; Ratnanather, J. Tilak; Miller, M. I.; Frush, Donald; Samei, Ehsan; Segars, W. Paul

    2014-03-01

    With the increased use of CT examinations, the associated radiation dose has become a large concern, especially for pediatrics. Much research has focused on reducing radiation dose through new scanning and reconstruction methods. Computational phantoms provide an effective and efficient means for evaluating image quality, patient-specific dose, and organ-specific dose in CT. We previously developed a set of highly-detailed 4D reference pediatric XCAT phantoms at ages of newborn, 1, 5, 10, and 15 years with organ and tissues masses matched to ICRP Publication 89 values. We now extend this reference set to a series of 64 pediatric phantoms of a variety of ages and height and weight percentiles, representative of the public at large. High resolution PET-CT data was reviewed by a practicing experienced radiologist for anatomic regularity and was then segmented with manual and semi-automatic methods to form a target model. A Multi-Channel Large Deformation Diffeomorphic Metric Mapping (MC-LDDMM) algorithm was used to calculate the transform from the best age matching pediatric reference phantom to the patient target. The transform was used to complete the target, filling in the non-segmented structures and defining models for the cardiac and respiratory motions. The complete phantoms, consisting of thousands of structures, were then manually inspected for anatomical accuracy. 3D CT data was simulated from the phantoms to demonstrate their ability to generate realistic, patient quality imaging data. The population of pediatric phantoms developed in this work provides a vital tool to investigate dose reduction techniques in 3D and 4D pediatric CT.

  7. Integration of the Opportunity-Ability-Motivation behavior change framework into a coaching-based WHO Safe Childbirth Checklist program in India.

    PubMed

    Hirschhorn, Lisa R; Krasne, Margaret; Maisonneuve, Jenny; Kara, Nabihah; Kalita, Tapan; Henrich, Natalie; Rana, Darpan; Maji, Pinki; Delaney, Megan M; Firestone, Rebecca; Sharma, Narender; Kumar, Vishwajeet; Gawande, Atul A; Semrau, Katherine E A

    2018-06-03

    To evaluate whether integration of the Opportunity-Ability-Motivation plus Supplies (OAMS) framework into coaching improved the delivery of essential birth practices in a low-resource setting. This prospective mixed-methods study used routine coaching visit data obtained from the first eight intervention facilities of the BetterBirth trial in Uttar Pradesh, India, between December 19, 2014, and October 21, 2015. The 8-month intervention was peer coaching that integrated the OAMS framework to support uptake of the WHO Safe Childbirth Checklist. Descriptive statistics were used to measure nonadherence to essential birth practices. The frequency and accuracy of coaches' coding of barriers and the appropriateness of chosen resolution strategies to measure feasibility, acceptability, and fidelity of using OAMS, were assessed. Coaches observed 666 deliveries, including 12 602 practices. Overall, essential practice nonadherence decreased from 15.6% (262/1675 practices observed) to 4.5% (4/88 practices) (P<0.001). Of the 1048 barriers identified, opportunity (556 [53.1%]) and motivation (287 [27.4%]) were the most frequently reported categories; the frequency of both decreased over time (P=0.003 and P<0.001, respectively). The coaches appropriately categorized 930 (99.8%) of 932 barriers and provided an appropriate strategy for 800 (85.8%). The commonest reason for unaddressed barriers was lack of coaching opportunities. Successful integration of OAMS framework into delivery attendant coaching enabled coaches to rapidly diagnose barriers to practice adherence and develop responsive strategies. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. A Confirmatory Study of Rating Scale Category Effectiveness for the Coaching Efficacy Scale

    ERIC Educational Resources Information Center

    Myers, Nicholas D.; Feltz, Deborah L.; Wolfe, Edward W.

    2008-01-01

    This study extended validity evidence for measures of coaching efficacy derived from the Coaching Efficacy Scale (CES) by testing the rating scale categorizations suggested in previous research. Previous research provided evidence for the effectiveness of a four-category (4-CAT) structure for high school and collegiate sports coaches; it also…

  9. Career Coaches as a Source of Vicarious Learning for Racial and Ethnic Minority PhD Students in the Biomedical Sciences: A Qualitative Study

    PubMed Central

    Williams, Simon N.; Thakore, Bhoomi K.; McGee, Richard

    2016-01-01

    Introduction Many recent mentoring initiatives have sought to help improve the proportion of underrepresented racial and ethnic minorities (URMs) in academic positions across the biomedical sciences. However, the intractable nature of the problem of underrepresentation suggests that many young scientists may require supplemental career development beyond what many mentors are able to offer. As an adjunct to traditional scientific mentoring, we created a novel academic career “coaching” intervention for PhD students in the biomedical sciences. Objective To determine whether and how academic career coaches can provide effective career-development-related learning experiences for URM PhD students in the biomedical sciences. We focus specifically on vicarious learning experiences, where individuals learn indirectly through the experiences of others. Method The intervention is being tested as part of a longitudinal randomized control trial (RCT). Here, we describe a nested qualitative study, using a framework approach to analyze data from a total of 48 semi-structured interviews from 24 URM PhD students (2 interviews per participant, 1 at baseline, 1 at 12-month follow-up) (16 female, 8 male; 11 Black, 12 Hispanic, 1 Native-American). We explored the role of the coach as a source of vicarious learning, in relation to the students’ goal of being future biomedical science faculty. Results Coaches were resources through which most students in the study were able to learn vicariously about how to pursue, and succeed within, an academic career. Coaches were particularly useful in instances where students’ research mentors are unable to provide such vicarious learning opportunities, for example because the mentor is too busy to have career-related discussions with a student, or because they have, or value, a different type of academic career to the type the student hopes to achieve. Implications Coaching can be an important way to address the lack of structured career development that students receive in their home training environment. PMID:27467084

  10. Effects of quantum noise in 4D-CT on deformable image registration and derived ventilation data

    NASA Astrophysics Data System (ADS)

    Latifi, Kujtim; Huang, Tzung-Chi; Feygelman, Vladimir; Budzevich, Mikalai M.; Moros, Eduardo G.; Dilling, Thomas J.; Stevens, Craig W.; van Elmpt, Wouter; Dekker, Andre; Zhang, Geoffrey G.

    2013-11-01

    Quantum noise is common in CT images and is a persistent problem in accurate ventilation imaging using 4D-CT and deformable image registration (DIR). This study focuses on the effects of noise in 4D-CT on DIR and thereby derived ventilation data. A total of six sets of 4D-CT data with landmarks delineated in different phases, called point-validated pixel-based breathing thorax models (POPI), were used in this study. The DIR algorithms, including diffeomorphic morphons (DM), diffeomorphic demons (DD), optical flow and B-spline, were used to register the inspiration phase to the expiration phase. The DIR deformation matrices (DIRDM) were used to map the landmarks. Target registration errors (TRE) were calculated as the distance errors between the delineated and the mapped landmarks. Noise of Gaussian distribution with different standard deviations (SD), from 0 to 200 Hounsfield Units (HU) in amplitude, was added to the POPI models to simulate different levels of quantum noise. Ventilation data were calculated using the ΔV algorithm which calculates the volume change geometrically based on the DIRDM. The ventilation images with different added noise levels were compared using Dice similarity coefficient (DSC). The root mean square (RMS) values of the landmark TRE over the six POPI models for the four DIR algorithms were stable when the noise level was low (SD <150 HU) and increased with added noise when the level is higher. The most accurate DIR was DD with a mean RMS of 1.5 ± 0.5 mm with no added noise and 1.8 ± 0.5 mm with noise (SD = 200 HU). The DSC values between the ventilation images with and without added noise decreased with the noise level, even when the noise level was relatively low. The DIR algorithm most robust with respect to noise was DM, with mean DSC = 0.89 ± 0.01 and 0.66 ± 0.02 for the top 50% ventilation volumes, as compared between 0 added noise and SD = 30 and 200 HU, respectively. Although the landmark TRE were stable with low noise, the differences between ventilation images increased with noise level, even when the noise was low, indicating ventilation imaging from 4D-CT was sensitive to image noise. Therefore, high quality 4D-CT is essential for accurate ventilation images.

  11. 4D Cone-beam CT reconstruction using a motion model based on principal component analysis

    PubMed Central

    Staub, David; Docef, Alen; Brock, Robert S.; Vaman, Constantin; Murphy, Martin J.

    2011-01-01

    Purpose: To provide a proof of concept validation of a novel 4D cone-beam CT (4DCBCT) reconstruction algorithm and to determine the best methods to train and optimize the algorithm. Methods: The algorithm animates a patient fan-beam CT (FBCT) with a patient specific parametric motion model in order to generate a time series of deformed CTs (the reconstructed 4DCBCT) that track the motion of the patient anatomy on a voxel by voxel scale. The motion model is constrained by requiring that projections cast through the deformed CT time series match the projections of the raw patient 4DCBCT. The motion model uses a basis of eigenvectors that are generated via principal component analysis (PCA) of a training set of displacement vector fields (DVFs) that approximate patient motion. The eigenvectors are weighted by a parameterized function of the patient breathing trace recorded during 4DCBCT. The algorithm is demonstrated and tested via numerical simulation. Results: The algorithm is shown to produce accurate reconstruction results for the most complicated simulated motion, in which voxels move with a pseudo-periodic pattern and relative phase shifts exist between voxels. The tests show that principal component eigenvectors trained on DVFs from a novel 2D/3D registration method give substantially better results than eigenvectors trained on DVFs obtained by conventionally registering 4DCBCT phases reconstructed via filtered backprojection. Conclusions: Proof of concept testing has validated the 4DCBCT reconstruction approach for the types of simulated data considered. In addition, the authors found the 2D/3D registration approach to be our best choice for generating the DVF training set, and the Nelder-Mead simplex algorithm the most robust optimization routine. PMID:22149852

  12. Simulation of dosimetric consequences of 4D-CT-based motion margin estimation for proton radiotherapy using patient tumor motion data

    NASA Astrophysics Data System (ADS)

    Koybasi, Ozhan; Mishra, Pankaj; St. James, Sara; Lewis, John H.; Seco, Joao

    2014-02-01

    For the radiation treatment of lung cancer patients, four-dimensional computed tomography (4D-CT) is a common practice used clinically to image tumor motion and subsequently determine the internal target volume (ITV) from the maximum intensity projection (MIP) images. ITV, which is derived from short pre-treatment 4D-CT scan (<6 s per couch position), may not adequately cover the extent of tumor motion during the treatment, particularly for patients that exhibit a large respiratory variability. Inaccurate tumor localization may result in under-dosage of the tumor or over-dosage of the surrounding tissues. The purpose of this study is therefore to assess the degree of tumor under-dosage in case of regular and irregular breathing for proton radiotherapy using ITV-based treatment planning. We place a spherical lesion into a modified XCAT phantom that is also capable of producing 4D images based on irregular breathing, and move the tumor according to real tumor motion data, which is acquired over multiple days by tracking gold fiducial markers implanted into the lung tumors of patients. We derive ITVs by taking the union of all tumor positions during 6 s of tumor motion in the phantom using the first day patient tumor tracking data. This is equivalent to ITVs generated clinically from cine-mode 4D-CT MIP images. The treatment plans created for different ITVs are then implemented on dynamic phantoms with tumor motion governed by real tumor tracking data from consecutive days. By comparing gross tumor volume dose distribution on days of ‘treatment’ with the ITV dose distribution, we evaluate the deviation of the actually delivered dose from the predicted dose. Our results have shown that the proton treatment planning on ITV derived from pre-treatment cine-mode 4D-CT can result in under-dosage (dose covering 95% of volume) of the tumor by up to 25.7% over 3 min of treatment for the patient with irregular respiratory motion. Tumor under-dosage is less significant for the patient with relatively regular breathing. We have demonstrated that proton therapy using the pre-treatment 4D-CT based ITV method can lead to significant under-dosage of the tumor, highlighting the need for daily customization to generate a target volume that represents tumor positions during the treatment more accurately.

  13. Automatic liver contouring for radiotherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Li, Dengwang; Liu, Li; Kapp, Daniel S.; Xing, Lei

    2015-09-01

    To develop automatic and efficient liver contouring software for planning 3D-CT and four-dimensional computed tomography (4D-CT) for application in clinical radiation therapy treatment planning systems. The algorithm comprises three steps for overcoming the challenge of similar intensities between the liver region and its surrounding tissues. First, the total variation model with the L1 norm (TV-L1), which has the characteristic of multi-scale decomposition and an edge-preserving property, is used for removing the surrounding muscles and tissues. Second, an improved level set model that contains both global and local energy functions is utilized to extract liver contour information sequentially. In the global energy function, the local correlation coefficient (LCC) is constructed based on the gray level co-occurrence matrix both of the initial liver region and the background region. The LCC can calculate the correlation of a pixel with the foreground and background regions, respectively. The LCC is combined with intensity distribution models to classify pixels during the evolutionary process of the level set based method. The obtained liver contour is used as the candidate liver region for the following step. In the third step, voxel-based texture characterization is employed for refining the liver region and obtaining the final liver contours. The proposed method was validated based on the planning CT images of a group of 25 patients undergoing radiation therapy treatment planning. These included ten lung cancer patients with normal appearing livers and ten patients with hepatocellular carcinoma or liver metastases. The method was also tested on abdominal 4D-CT images of a group of five patients with hepatocellular carcinoma or liver metastases. The false positive volume percentage, the false negative volume percentage, and the dice similarity coefficient between liver contours obtained by a developed algorithm and a current standard delineated by the expert group are on an average 2.15-2.57%, 2.96-3.23%, and 91.01-97.21% for the CT images with normal appearing livers, 2.28-3.62%, 3.15-4.33%, and 86.14-93.53% for the CT images with hepatocellular carcinoma or liver metastases, and 2.37-3.96%, 3.25-4.57%, and 82.23-89.44% for the 4D-CT images also with hepatocellular carcinoma or liver metastases, respectively. The proposed three-step method can achieve efficient automatic liver contouring for planning CT and 4D-CT images with follow-up treatment planning and should find widespread applications in future treatment planning systems.

  14. The Impact of Telephonic Wellness Coaching on Weight Loss: A “Natural Experiments for Translation in Diabetes (NEXT-D)” Study

    PubMed Central

    Schmittdiel, Julie A.; Adams, Sara R.; Goler, Nancy; Sanna, Rashel S.; Boccio, Mindy; Bellamy, David J.; Brown, Susan D.; Neugebauer, Romain S.; Ferrara, Assiamira

    2016-01-01

    Objective To evaluate the impact of a population-based telephonic wellness coaching program on weight loss. Methods Individual-level segmented regression analysis of interrupted time series data comparing the BMI trajectories in the 12 months before vs. the 12 months after initiating coaching among a cohort of Kaiser Permanente Northern California (KPNC) members (n=954) participating in The Permanente Medical Group (TPMG) Wellness Coaching program in 2011. The control group was a 20:1 propensity-score matched control group (n=19,080) matched with coaching participants based on baseline demographic and clinical characteristics. Results Wellness coaching participants had a significant upward trend in BMI in the 12 months before their first Wellness coaching session, and a significant downward trend in BMI in the 12 months after their first session equivalent to a clinically significant reduction of greater than one unit of baseline BMI (p<.01 for both). The control group did not have statistically significant decreases in BMI during the post-period. Conclusions Wellness coaching has a positive impact on BMI reduction that is both statistically and clinically significant. Future research and quality improvement efforts should focus on disseminating Wellness coaching for weight loss in diabetes patients and those at risk for developing the disease. PMID:28124501

  15. Coaching to Augment Mentoring to Achieve Faculty Diversity: A Randomized Controlled Trial.

    PubMed

    Williams, Simon N; Thakore, Bhoomi K; McGee, Richard

    2016-08-01

    The Academy for Future Science Faculty (the Academy) is a novel coaching intervention for biomedical PhD students designed to address limitations in previous efforts to promote faculty diversity. Unlike traditional research mentoring, the Academy includes both group and individual coaching, coaches have no research or evaluation roles with the students, and it is based on social science theories. The authors present a qualitative case study of one of the coaching groups and provide statistical analyses indicating whether one year in the Academy effects students' perceptions of the achievability and desirability of an academic career. The authors tested (July 2012-July 2013), with Northwestern University ethical approval, the Academy via a longitudinal randomized controlled trial. Participants were 121 latter-stage biomedical PhD students. The authors collected data via questionnaires, interviews, and meeting recordings. The case study shows how group career coaching can effectively supplement traditional one-to-one research mentoring; provide new role models for underrepresented minority students; and provide theory-based lenses through which to engage in open conversations about race, gender, and science careers. Repeated-measures analysis of variance showed that perceived achievability increased in the Academy group from baseline to one-year follow-up (mean, 5.75 versus 6.39) but decreased in the control group (6.58 versus 5.81). Perceived desirability decreased significantly less (P < .05) in the Academy group (7.00 versus 6.36) than in the control group (7.83 versus 5.97). Early results suggest that an academic career coaching model can effectively supplement traditional research mentoring and promote persistence toward academic careers.

  16. Correspondence between training load executed by volleyball players and the one observed by coaches.

    PubMed

    Rodríguez-Marroyo, Jose A; Medina, Javier; García-López, Juan; García-Tormo, José V; Foster, Carl

    2014-06-01

    The main aim of this study was to compare the training load (TL) executed by volleyball players with that observed by coaches. Second, we analyzed the influence of the coaches' experience in the estimated TL. Twelve female volleyball players and 4 male coaches participated in this study. During a period of 15 weeks, physical (PT) and technical-tactical training sessions and matches were monitored. In each session, the session rating of perceived exertion (sRPE) was recorded to analyze the players' exercise intensity and TL(RP)E. Coaches were present in all sessions and rated their estimate of sRPE at the same time as the players to calculate the coaches' TL(RPE). Both players' and coaches' mean sRPE (4.0 ± 1.1, 3.7 ± 1.1, and 3.8 ± 1.0 in players and expert and beginning coaches, respectively) and TLRPE (380.1 ± 106.8, 358.3 ± 110.5, and 359.7 ± 108.0 in players and expert and beginning coaches, respectively) were similar. However, a higher (p < 0.01) sRPE and TL(RPE) were observed in the players during PT. In general, the weekly TL(RPE) variation over the course of this study was similar in players and coaches. The players' sRPE and TL(RPE) were correlated (p < 0.01) with expert and beginner coaches' RPE (r = 0.70 and 0.72, respectively) and TL(RPE) (r = 0.75 and 0.76, respectively). In conclusion, the present findings show the correspondence between players' and coaches' sRPE and TL(RPE) regardless of their experience. Hence, coaches' TL(RPE) could be a useful and practical method to monitor and control the TL and other derived parameters in an easy way during volleyball.

  17. 4D CT-based Treatment Planning for Intensity-Modulated Radiation Therapy and Proton Therapy for Distal Esophagus Cancer

    PubMed Central

    Zhang, Xiaodong; Zhao, Kuai-Le; Guerrero, Thomas M.; McGuire, Sean E.; Yaremko, Brian; Komaki, Ritsuko; Cox, James D.; Hui, Zhouguang; Li, Yupeng; Newhauser, Wayne D.; Mohan, Radhe; Liao, Zhongxing

    2008-01-01

    Purpose To compare three-dimensional (3D) and 4D computed tomography (CT)– based treatment plans for proton therapy or intensity-modulated radiation therapy (IMRT) for esophageal cancer in terms of doses to the lung, heart, and spinal cord and variations in target coverage and normal tissue sparing. Materials and Methods IMRT and proton plans for 15 patients with distal esophageal cancer were designed from the 3D average CT scans and then recalculated on 10 4D CT data sets. Dosimetric data were compared for tumor coverage and normal tissue sparing. Results Compared with IMRT, median lung volumes exposed to 5,10, and 20 Gy and mean lung dose were reduced by 35.6%, 20.5%,5.8%, and 5.1 Gy for a two-beam proton plan and by 17.4%,8.4%,5%, and 2.9 Gy for a three-beam proton plan. The greater lung sparing in the two-beam proton plan was achieved at the expense of less conformity to the target (conformity index CI=1.99) and greater irradiation of the heart (heart-V40=41.8%) compared with the IMRT plan(CI=1.55, heart-V40=35.7%) or the three-beam proton plan (CI=1.46, heart-V40=27.7%). Target coverage differed by more than 2% between the 3D and 4D plans for patients with substantial diaphragm motion in the three-beam proton and IMRT plans. The difference in spinal cord maximum dose between 3D and 4D plans could exceed 5 Gy for the proton plans partly owing to variations in stomach gas-filling. Conclusions Proton therapy provided significantly better sparing of lung than did IMRT. Diaphragm motion and stomach gas-filling must be considered in evaluating target coverage and cord doses. PMID:18722278

  18. Coaching for Performance. Second Edition. People Skills for Professionals Series.

    ERIC Educational Resources Information Center

    Whitmore, John

    This book teaches the skills and art of good coaching and how to realize its value in unlocking people's potential to maximize their own performance. Chapters 1-3 define coaching and its business application, discuss the manager as coach and the manager's role, and examine the context of change. Chapter 4 considers the two key elements of…

  19. Coach strategies for addressing psychosocial challenges during the return to sport from injury.

    PubMed

    Podlog, Leslie; Dionigi, Rylee

    2010-09-01

    The purpose of this study was to examine coach strategies for addressing athletes' psychosocial challenges in returning to sport following injury rehabilitation. Qualitative interviews with eight elite coaches from the Western Australian Institute of Sport (WAIS) in Perth, Australia revealed that coaches facilitated athletes' return to sport from injury through a variety of means, but did not typically provide systematic forms of assistance. Coaches commented that the idiosyncratic nature of the injury experience meant that they needed to apply strategies consistent with athletes' particular psychosocial needs. Such strategies included: (a) coordination of a "team approach" to rehabilitation; (b) fostering open communication with athletes and treatment team members; (c) social support; (d) positive thinking and goal setting; and (e) role models. Analysis of these strategies revealed that coaches attempted to address competence, autonomy, and relatedness needs in facilitating athletes' return from injury. These findings suggest that self-determination theory may be a valuable approach for examining coach forms of assistance regarding athletes' return to competition following injury. Findings are discussed in relation to injury literature and self-determination theory. Suggestions for future research are also presented.

  20. Peer Coaching Interventions for Parents of Children with Type 1 Diabetes.

    PubMed

    Tully, Carrie; Shneider, Caitlin; Monaghan, Maureen; Hilliard, Marisa E; Streisand, Randi

    2017-06-01

    Peer support is a promising model of providing psychosocial support to parents of children with type 1 diabetes. This review seeks to discuss the findings of the existing literature in peer coaching as it relates to parents and diabetes as well as to identify gaps in knowledge for future intervention development and implementation. Peer support programs vary widely with regard to recruitment, training, and delivery protocols. Across most programs, ongoing support and supervision are provided to peer coaches. Despite inconsistent effects on psychosocial and child health outcomes, parent coaching is consistently a highly acceptable and feasible intervention with parents of children with T1D. Current evidence supports use of parent coaching as part of a multicomponent intervention or program to increase patient satisfaction, but more research is needed to determine if it can stand alone as an active mechanism for behavior change. The use of peer coach interventions for parents of young children with diabetes is feasible to implement and highly acceptable. However, more research is needed to understand the enduring impact for target parents and peer coaches alike, as well as impact on child outcomes.

  1. High-resolution three-dimensional visualization of the rat spinal cord microvasculature by synchrotron radiation micro-CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Jianzhong; Cao, Yong; Wu, Tianding

    2014-10-15

    Purpose: Understanding the three-dimensional (3D) morphology of the spinal cord microvasculature has been limited by the lack of an effective high-resolution imaging technique. In this study, synchrotron radiation microcomputed tomography (SRµCT), a novel imaging technique based on absorption imaging, was evaluated with regard to the detection of the 3D morphology of the rat spinal cord microvasculature. Methods: Ten Sprague-Dawley rats were used in this ex vivo study. After contrast agent perfusion, their spinal cords were isolated and scanned using conventional x-rays, conventional micro-CT (CµCT), and SRµCT. Results: Based on contrast agent perfusion, the microvasculature of the rat spinal cord wasmore » clearly visualized for the first time ex vivo in 3D by means of SRµCT scanning. Compared to conventional imaging techniques, SRµCT achieved higher resolution 3D vascular imaging, with the smallest vessel that could be distinguished approximately 7.4 μm in diameter. Additionally, a 3D pseudocolored image of the spinal cord microvasculature was generated in a single session of SRµCT imaging, which was conducive to detailed observation of the vessel morphology. Conclusions: The results of this study indicated that SRµCT scanning could provide higher resolution images of the vascular network of the spinal cord. This modality also has the potential to serve as a powerful imaging tool for the investigation of morphology changes in the 3D angioarchitecture of the neurovasculature in preclinical research.« less

  2. Group climate in the voice therapy of patients with Parkinson's Disease.

    PubMed

    Diaféria, Giovana; Madazio, Glaucya; Pacheco, Claudia; Takaki, Patricia Barbarini; Behlau, Mara

    2017-09-04

    To verify the impact that group dynamics and coaching strategies have on the PD patients voice, speech and communication, as well as the group climate. 16 individuals with mild to moderate dysarthria due to the PD were divided into two groups: the CG (8 patients), submitted to traditional therapy with 12 regular therapy sessions plus 4 additional support sessions; and the EG (8 patients), submitted to traditional therapy with 12 regular therapy sessions plus 4 sessions with group dynamics and coaching strategies. The Living with Dysarthria questionnaire (LwD), the self-evaluation of voice, speech and communication, and the perceptual-auditory analysis of the vocal quality were assess in 3 moments: pre-traditional therapy (pre); post-traditional therapy (post 1); and post support sessions/coaching strategies (post 2); in post 1 and post 2 moments, the Group Climate Questionnaire (GCQ) was also applied. CG and EG showed an improvement in the LwD from pre to post 1 and post 2 moments. Voice self-evaluation was better for the EG - when pre was compared with post 2 and when post 1 was compared with post 2 - ranging from regular to very good; both groups presented improvement in the communication self-evaluation. The perceptual-auditory evaluation of the vocal quality was better for the EG in the post 1 moment. No difference was found for the GCQ; however, the EG presented lower avoidance scores in post 2. All patients showed improvement in the voice, speech and communication self-evaluation; EG showed lower avoidance scores, creating a more collaborative and propitious environment for speech therapy.

  3. Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landry, Guillaume, E-mail: g.landry@lmu.de; Nijhuis, Reinoud; Thieke, Christian

    2015-03-15

    Purpose: Intensity modulated proton therapy (IMPT) of head and neck (H and N) cancer patients may be improved by plan adaptation. The decision to adapt the treatment plan based on a dose recalculation on the current anatomy requires a diagnostic quality computed tomography (CT) scan of the patient. As gantry-mounted cone beam CT (CBCT) scanners are currently being offered by vendors, they may offer daily or weekly updates of patient anatomy. CBCT image quality may not be sufficient for accurate proton dose calculation and it is likely necessary to perform CBCT CT number correction. In this work, the authors investigatedmore » deformable image registration (DIR) of the planning CT (pCT) to the CBCT to generate a virtual CT (vCT) to be used for proton dose recalculation. Methods: Datasets of six H and N cancer patients undergoing photon intensity modulated radiation therapy were used in this study to validate the vCT approach. Each dataset contained a CBCT acquired within 3 days of a replanning CT (rpCT), in addition to a pCT. The pCT and rpCT were delineated by a physician. A Morphons algorithm was employed in this work to perform DIR of the pCT to CBCT following a rigid registration of the two images. The contours from the pCT were deformed using the vector field resulting from DIR to yield a contoured vCT. The DIR accuracy was evaluated with a scale invariant feature transform (SIFT) algorithm comparing automatically identified matching features between vCT and CBCT. The rpCT was used as reference for evaluation of the vCT. The vCT and rpCT CT numbers were converted to stopping power ratio and the water equivalent thickness (WET) was calculated. IMPT dose distributions from treatment plans optimized on the pCT were recalculated with a Monte Carlo algorithm on the rpCT and vCT for comparison in terms of gamma index, dose volume histogram (DVH) statistics as well as proton range. The DIR generated contours on the vCT were compared to physician-drawn contours on the rpCT. Results: The DIR accuracy was better than 1.4 mm according to the SIFT evaluation. The mean WET differences between vCT (pCT) and rpCT were below 1 mm (2.6 mm). The amount of voxels passing 3%/3 mm gamma criteria were above 95% for the vCT vs rpCT. When using the rpCT contour set to derive DVH statistics from dose distributions calculated on the rpCT and vCT the differences, expressed in terms of 30 fractions of 2 Gy, were within [−4, 2 Gy] for parotid glands (D{sub mean}), spinal cord (D{sub 2%}), brainstem (D{sub 2%}), and CTV (D{sub 95%}). When using DIR generated contours for the vCT, those differences ranged within [−8, 11 Gy]. Conclusions: In this work, the authors generated CBCT based stopping power distributions using DIR of the pCT to a CBCT scan. DIR accuracy was below 1.4 mm as evaluated by the SIFT algorithm. Dose distributions calculated on the vCT agreed well to those calculated on the rpCT when using gamma index evaluation as well as DVH statistics based on the same contours. The use of DIR generated contours introduced variability in DVH statistics.« less

  4. SU-C-207-01: Four-Dimensional Inverse Geometry Computed Tomography: Concept and Its Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, K; Kim, D; Kim, T

    2015-06-15

    Purpose: In past few years, the inverse geometry computed tomography (IGCT) system has been developed to overcome shortcomings of a conventional computed tomography (CT) system such as scatter problem induced from large detector size and cone-beam artifact. In this study, we intend to present a concept of a four-dimensional (4D) IGCT system that has positive aspects above all with temporal resolution for dynamic studies and reduction of motion artifact. Methods: Contrary to conventional CT system, projection data at a certain angle in IGCT was a group of fractionated narrow cone-beam projection data, projection group (PG), acquired from multi-source array whichmore » have extremely short time gap of sequential operation between each of sources. At this, for 4D IGCT imaging, time-related data acquisition parameters were determined by combining multi-source scanning time for collecting one PG with conventional 4D CBCT data acquisition sequence. Over a gantry rotation, acquired PGs from multi-source array were tagged time and angle for 4D image reconstruction. Acquired PGs were sorted into 10 phase and image reconstructions were independently performed at each phase. Image reconstruction algorithm based upon filtered-backprojection was used in this study. Results: The 4D IGCT had uniform image without cone-beam artifact on the contrary to 4D CBCT image. In addition, the 4D IGCT images of each phase had no significant artifact induced from motion compared with 3D CT. Conclusion: The 4D IGCT image seems to give relatively accurate dynamic information of patient anatomy based on the results were more endurable than 3D CT about motion artifact. From this, it will be useful for dynamic study and respiratory-correlated radiation therapy. This work was supported by the Industrial R&D program of MOTIE/KEIT [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.« less

  5. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    NASA Astrophysics Data System (ADS)

    Bowen, S. R.; Nyflot, M. J.; Herrmann, C.; Groh, C. M.; Meyer, J.; Wollenweber, S. D.; Stearns, C. W.; Kinahan, P. E.; Sandison, G. A.

    2015-05-01

    Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [18F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery.

  6. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study.

    PubMed

    Bowen, S R; Nyflot, M J; Herrmann, C; Groh, C M; Meyer, J; Wollenweber, S D; Stearns, C W; Kinahan, P E; Sandison, G A

    2015-05-07

    Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [(18)F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery.

  7. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    PubMed Central

    Bowen, S R; Nyflot, M J; Hermann, C; Groh, C; Meyer, J; Wollenweber, S D; Stearns, C W; Kinahan, P E; Sandison, G A

    2015-01-01

    Effective positron emission tomography/computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [18F]FDG. The lung lesion insert was driven by 6 different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy (VMAT) were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses (EUD), and 2%-2mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10–20%, treatment planning errors were 5–10%, and treatment delivery errors were 5–30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5–10% in PET/CT imaging, < 5% in treatment planning, and < 2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery. PMID:25884892

  8. Mobile Phone Support for Diabetes Self-Care Among Diverse Adults: Protocol for a Three-Arm Randomized Controlled Trial.

    PubMed

    Nelson, Lyndsay A; Wallston, Kenneth A; Kripalani, Sunil; Greevy, Robert A; Elasy, Tom A; Bergner, Erin M; Gentry, Chad K; Mayberry, Lindsay S

    2018-04-10

    Nonadherence to self-care is common among patients with type 2 diabetes (T2D) and often leads to severe complications. Moreover, patients with T2D who have low socioeconomic status and are racial/ethnic minorities disproportionately experience barriers to adherence and poor outcomes. Basic phone technology (text messages and phone calls) provides a practical medium for delivering content to address patients' barriers to adherence; however, trials are needed to explore long-term and sustainable effects of mobile phone interventions among diverse patients. The aim of this study is to evaluate the effects of mobile phone-based diabetes support interventions on self-care and hemoglobin A 1c (HbA 1c ) among adults with T2D using a 3-arm, 15-month randomized controlled trial with a Type 1 hybrid effectiveness-implementation approach. The intervention arms are (1) Rapid Encouragement/Education And Communications for Health (REACH) and (2) REACH + Family-focused Add-on for Motivating Self-care (FAMS). We recruited primary care patients with T2D (N=512) from Federally Qualified Health Centers and an academic medical center, prioritizing recruitment of publicly insured and minority patients from the latter. Eligible patients were prescribed daily diabetes medication and owned a cell phone with text messaging capability. We excluded patients whose most recent HbA 1c result within 12 months was <6.8% to support detection of intervention effects on HbA 1c . Participants were randomly assigned to REACH only, REACH + FAMS, or the control condition. REACH provides text messages tailored to address patient-specific barriers to medication adherence based on the Information-Motivation-Behavioral skills model, whereas FAMS provides monthly phone coaching with related text message content focused on family and friend barriers to diet and exercise adherence. We collect HbA 1c and self-reported survey data at baseline and at 3, 6, and 12 months, and again at 15 months to assess sustained changes. We will use generalized estimating equation models to test the effects of REACH (either intervention arm) on HbA 1c relative to the control group, the potential additive effects of FAMS, and effects of either intervention on adherence to self-care behaviors and diabetes self-efficacy. The trial is ongoing; recruitment closed December 2017. We plan to perform analyses on 6-month outcomes for FAMS in July 2018, and project to have 15-month data for REACH analyses in April 2019. Our study will be one of the first to evaluate a long-term, theory-based text messaging intervention to promote self-care adherence among racially/ethnically and socioeconomically diverse adults with T2D. Moreover, our study will assess the feasibility of a family-focused intervention delivered via mobile phones and compare the effects of text messaging alone versus text messaging plus phone coaching. Findings will advance our understanding of how interventions delivered by phone can benefit diverse patients with chronic conditions. ClinicalTrials.gov NCT02409329; https://clinicaltrials.gov/ct2/show/NCT02409329 (Archived by WebCite at http://www.webcitation.org/6yHkg9SSl); NCT02481596; https://clinicaltrials.gov/ct2/show/NCT02481596 (Archived by WebCite at http://www.webcitation.org/6yHkj9XD4). ©Lyndsay A Nelson, Kenneth A Wallston, Sunil Kripalani, Robert A Greevy Jr, Tom A Elasy, Erin M Bergner, Chad K Gentry, Lindsay S Mayberry. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 10.04.2018.

  9. Mobile Phone Support for Diabetes Self-Care Among Diverse Adults: Protocol for a Three-Arm Randomized Controlled Trial

    PubMed Central

    Nelson, Lyndsay A; Wallston, Kenneth A; Kripalani, Sunil; Greevy Jr, Robert A; Elasy, Tom A; Bergner, Erin M; Gentry, Chad K

    2018-01-01

    Background Nonadherence to self-care is common among patients with type 2 diabetes (T2D) and often leads to severe complications. Moreover, patients with T2D who have low socioeconomic status and are racial/ethnic minorities disproportionately experience barriers to adherence and poor outcomes. Basic phone technology (text messages and phone calls) provides a practical medium for delivering content to address patients’ barriers to adherence; however, trials are needed to explore long-term and sustainable effects of mobile phone interventions among diverse patients. Objective The aim of this study is to evaluate the effects of mobile phone–based diabetes support interventions on self-care and hemoglobin A1c (HbA1c) among adults with T2D using a 3-arm, 15-month randomized controlled trial with a Type 1 hybrid effectiveness-implementation approach. The intervention arms are (1) Rapid Encouragement/Education And Communications for Health (REACH) and (2) REACH + Family-focused Add-on for Motivating Self-care (FAMS). Methods We recruited primary care patients with T2D (N=512) from Federally Qualified Health Centers and an academic medical center, prioritizing recruitment of publicly insured and minority patients from the latter. Eligible patients were prescribed daily diabetes medication and owned a cell phone with text messaging capability. We excluded patients whose most recent HbA1c result within 12 months was <6.8% to support detection of intervention effects on HbA1c. Participants were randomly assigned to REACH only, REACH + FAMS, or the control condition. REACH provides text messages tailored to address patient-specific barriers to medication adherence based on the Information-Motivation-Behavioral skills model, whereas FAMS provides monthly phone coaching with related text message content focused on family and friend barriers to diet and exercise adherence. We collect HbA1c and self-reported survey data at baseline and at 3, 6, and 12 months, and again at 15 months to assess sustained changes. We will use generalized estimating equation models to test the effects of REACH (either intervention arm) on HbA1c relative to the control group, the potential additive effects of FAMS, and effects of either intervention on adherence to self-care behaviors and diabetes self-efficacy. Results The trial is ongoing; recruitment closed December 2017. We plan to perform analyses on 6-month outcomes for FAMS in July 2018, and project to have 15-month data for REACH analyses in April 2019. Conclusions Our study will be one of the first to evaluate a long-term, theory-based text messaging intervention to promote self-care adherence among racially/ethnically and socioeconomically diverse adults with T2D. Moreover, our study will assess the feasibility of a family-focused intervention delivered via mobile phones and compare the effects of text messaging alone versus text messaging plus phone coaching. Findings will advance our understanding of how interventions delivered by phone can benefit diverse patients with chronic conditions. Trial Registration ClinicalTrials.gov NCT02409329; https://clinicaltrials.gov/ct2/show/NCT02409329 (Archived by WebCite at http://www.webcitation.org/6yHkg9SSl); NCT02481596; https://clinicaltrials.gov/ct2/show/NCT02481596 (Archived by WebCite at http://www.webcitation.org/6yHkj9XD4) PMID:29636319

  10. Performance evaluations of demons and free form deformation algorithms for the liver region.

    PubMed

    Wang, Hui; Gong, Guanzhong; Wang, Hongjun; Li, Dengwang; Yin, Yong; Lu, Jie

    2014-04-01

    We investigated the influence of breathing motion on radiation therapy according to four- dimensional computed tomography (4D-CT) technology and indicated the registration of 4D-CT images was significant. The demons algorithm in two interpolation modes was compared to the FFD model algorithm to register the different phase images of 4D-CT in tumor tracking, using iodipin as verification. Linear interpolation was used in both mode 1 and mode 2. Mode 1 set outside pixels to nearest pixel, while mode 2 set outside pixels to zero. We used normalized mutual information (NMI), sum of squared differences, modified Hausdorff-distance, and registration speed to evaluate the performance of each algorithm. The average NMI after demons registration method in mode 1 improved 1.76% and 4.75% when compared to mode 2 and FFD model algorithm, respectively. Further, the modified Hausdorff-distance was no different between demons modes 1 and 2, but mode 1 was 15.2% lower than FFD. Finally, demons algorithm has the absolute advantage in registration speed. The demons algorithm in mode 1 was therefore found to be much more suitable for the registration of 4D-CT images. The subtractions of floating images and reference image before and after registration by demons further verified that influence of breathing motion cannot be ignored and the demons registration method is feasible.

  11. 4D micro-CT using fast prospective gating

    NASA Astrophysics Data System (ADS)

    Guo, Xiaolian; Johnston, Samuel M.; Qi, Yi; Johnson, G. Allan; Badea, Cristian T.

    2012-01-01

    Micro-CT is currently used in preclinical studies to provide anatomical information. But, there is also significant interest in using this technology to obtain functional information. We report here a new sampling strategy for 4D micro-CT for functional cardiac and pulmonary imaging. Rapid scanning of free-breathing mice is achieved with fast prospective gating (FPG) implemented on a field programmable gate array. The method entails on-the-fly computation of delays from the R peaks of the ECG signals or the peaks of the respiratory signals for the triggering pulses. Projection images are acquired for all cardiac or respiratory phases at each angle before rotating to the next angle. FPG can deliver the faster scan time of retrospective gating (RG) with the regular angular distribution of conventional prospective gating for cardiac or respiratory gating. Simultaneous cardio-respiratory gating is also possible with FPG in a hybrid retrospective/prospective approach. We have performed phantom experiments to validate the new sampling protocol and compared the results from FPG and RG in cardiac imaging of a mouse. Additionally, we have evaluated the utility of incorporating respiratory information in 4D cardiac micro-CT studies with FPG. A dual-source micro-CT system was used for image acquisition with pulsed x-ray exposures (80 kVp, 100 mA, 10 ms). The cardiac micro-CT protocol involves the use of a liposomal blood pool contrast agent containing 123 mg I ml-1 delivered via a tail vein catheter in a dose of 0.01 ml g-1 body weight. The phantom experiment demonstrates that FPG can distinguish the successive phases of phantom motion with minimal motion blur, and the animal study demonstrates that respiratory FPG can distinguish inspiration and expiration. 4D cardiac micro-CT imaging with FPG provides image quality superior to RG at an isotropic voxel size of 88 µm and 10 ms temporal resolution. The acquisition time for either sampling approach is less than 5 min. The radiation dose associated with the proposed method is in the range of a typical micro-CT dose (256 mGy for the cardiac study). Ignoring respiration does not significantly affect anatomic information in cardiac studies. FPG can deliver short scan times with low-dose 4D micro-CT imaging without sacrificing image quality. FPG can be applied in high-throughput longitudinal studies in a wide range of applications, including drug safety and cardiopulmonary phenotyping.

  12. Strength and conditioning practices in rowing.

    PubMed

    Gee, Thomas I; Olsen, Peter D; Berger, Nicolas J; Golby, Jim; Thompson, Kevin G

    2011-03-01

    There is limited published research on the practices of strength and conditioning (S &C) coaches in Great Britain. Information about training program design would be useful in developing models of good practice and ecologically valid intervention studies. The aim of this research was to quantify the training practices of coaches responsible for the S&C of rowing athletes. A questionnaire was developed that consisted of 6 sections: (a) personal details, (b) physical testing, (c) strength and power development, (d) flexibility development, (e) unique aspects of the program, and (f) any further relevant comments regarding the athletes prescribed training program. Twenty-two rowing and 10 S&C coaches with an average of 10.5 ± 7.2 years' experience agreed to complete the questionnaire. Approximately, 34% coached rowers of Olympic standard, 34% coached national standard, 3% coached regional standard, 19% coached club standard, and 10% coached university standard rowers. All coaches agreed that strength training enhanced rowing performance and the majority (74%) indicated that athletes' strength trained 2-3 times a week. Almost all coaches (94%) reported their rowers performed strength training, with 81% using Olympic lifting, and 91% employing a periodized training model. The clean (63%) and squat (27%) were rated the most important prescribed exercises. Approximately 50% of coaches used plyometrics such as depth jumps, box drills, and standing jumps. Ninety-four percent indicated they conducted physical testing on their rowers, typically assessing cardiovascular endurance (80%), muscular power (70%), muscular strength (70%), and anaerobic capacity (57%). This research represents the only published survey to date on the S&C practices in rowing within Great Britain.

  13. Development of real-time motion verification system using in-room optical images for respiratory-gated radiotherapy.

    PubMed

    Park, Yang-Kyun; Son, Tae-geun; Kim, Hwiyoung; Lee, Jaegi; Sung, Wonmo; Kim, Il Han; Lee, Kunwoo; Bang, Young-bong; Ye, Sung-Joon

    2013-09-06

    Phase-based respiratory-gated radiotherapy relies on the reproducibility of patient breathing during the treatment. To monitor the positional reproducibility of patient breathing against a 4D CT simulation, we developed a real-time motion verification system (RMVS) using an optical tracking technology. The system in the treatment room was integrated with a real-time position management system. To test the system, an anthropomorphic phantom that was mounted on a motion platform moved on a programmed breathing pattern and then underwent a 4D CT simulation with RPM. The phase-resolved anterior surface lines were extracted from the 4D CT data to constitute 4D reference lines. In the treatment room, three infrared reflective markers were attached on the superior, middle, and inferior parts of the phantom along with the body midline and then RMVS could track those markers using an optical camera system. The real-time phase information extracted from RPM was delivered to RMVS via in-house network software. Thus, the real-time anterior-posterior positions of the markers were simultaneously compared with the 4D reference lines. The technical feasibility of RMVS was evaluated by repeating the above procedure under several scenarios such as ideal case (with identical motion parameters between simulation and treatment), cycle change, baseline shift, displacement change, and breathing type changes (abdominal or chest breathing). The system capability for operating under irregular breathing was also investigated using real patient data. The evaluation results showed that RMVS has a competence to detect phase-matching errors between patient's motion during the treatment and 4D CT simulation. Thus, we concluded that RMVS could be used as an online quality assurance tool for phase-based gating treatments.

  14. Effect of N-acetylcysteine on the early expression of inflammatory markers in the retina and plasma of diabetic rats.

    PubMed

    Tsai, Gina Y; Cui, Jing Z; Syed, Husnain; Xia, Zhengyuan; Ozerdem, Ugur; McNeill, John H; Matsubara, Joanne A

    2009-03-01

    The aim of this study is to investigate markers of inflammation and oxidative stress in an early model of diabetic retinopathy, correlate retinal and plasma results and evaluate the influence of treatment by N-acetylcysteine (NAC), a free radical scavenger. Four groups were studied: control (C), streptozotocin (STZ)-induced diabetic rats (D), STZ rats following 8 weeks of NAC (DT), and control rats following 8 weeks of NAC (CT). Plasma levels of free 15-F2t-isoprostane (15-F-2t-IsoP), superoxide dismutase (SOD) and tumour necrosis factor-alpha (TNF-alpha) were obtained. Primary antibodies against macrophages (ED-1), microglia (Ox-42), pericytes (NG-2), endothelial and perivascular cells (IB-4), haem oxygenase 1 (HO-1) and vascular endothelial growth factor (VEGF) were used. Expression of NG-2 was robust in C, CT, DT, and mild in D. The intensity of IB-4 was higher in D and DT compared with the C and CT. Ox-42 and ED-1 expression was higher in the D than in the DT, C or CT. Expression of VEGF and HO-1 was non-specific across the four groups. Plasma levels of 15-F-2t-IsoP and TNF-alpha were higher in the D as compared with the C, CT and DT. SOD levels were lower in the D when compared with the C, CT and D. Macrophage/microglia activation, pericyte loss and endothelial/perivascular cell changes occur early in the pathogenesis of DR. These changes are associated with an increase in plasma markers of oxidative stress and inflammation and are minimized by treatment with NAC. The results suggest that therapies that reduce free radicals will help minimize the early events in diabetic retinopathy in the STZ model.

  15. [Validation of an improved Demons deformable registration algorithm and its application in re-contouring in 4D-CT].

    PubMed

    Zhen, Xin; Zhou, Ling-hong; Lu, Wen-ting; Zhang, Shu-xu; Zhou, Lu

    2010-12-01

    To validate the efficiency and accuracy of an improved Demons deformable registration algorithm and evaluate its application in contour recontouring in 4D-CT. To increase the additional Demons force and reallocate the bilateral forces to accelerate convergent speed, we propose a novel energy function as the similarity measure, and utilize a BFGS method for optimization to avoid specifying the numbers of iteration. Mathematical transformed deformable CT images and home-made deformable phantom were used to validate the accuracy of the improved algorithm, and its effectiveness for contour recontouring was tested. The improved algorithm showed a relatively high registration accuracy and speed when compared with the classic Demons algorithm and optical flow based method. Visual inspection of the positions and shapes of the deformed contours agreed well with the physician-drawn contours. Deformable registration is a key technique in 4D-CT, and this improved Demons algorithm for contour recontouring can significantly reduce the workload of the physicians. The registration accuracy of this method proves to be sufficient for clinical needs.

  16. The impact of telephonic wellness coaching on weight loss: A "Natural Experiments for Translation in Diabetes (NEXT-D)" study.

    PubMed

    Schmittdiel, Julie A; Adams, Sara R; Goler, Nancy; Sanna, Rashel S; Boccio, Mindy; Bellamy, David J; Brown, Susan D; Neugebauer, Romain S; Ferrara, Assiamira

    2017-02-01

    To evaluate the impact of a population-based telephonic wellness coaching program on weight loss. Individual-level segmented regression analysis of interrupted time series data comparing the BMI trajectories in the 12 months before versus the 12 months after initiating coaching among a cohort of Kaiser Permanente Northern California members (n = 954) participating in The Permanente Medical Group Wellness Coaching program in 2011. The control group was a 20:1 propensity-score matched control group (n = 19,080) matched with coaching participants based on baseline demographic and clinical characteristics. Wellness coaching participants had a significant upward trend in BMI in the 12 months before their first wellness coaching session and a significant downward trend in BMI in the 12 months after their first session equivalent to a clinically significant reduction of greater than one unit of baseline BMI (P < 0.01 for both). The control group did not have statistically significant decreases in BMI during the post-period. Wellness coaching has a positive impact on BMI reduction that is both statistically and clinically significant. Future research and quality improvement efforts should focus on disseminating wellness coaching for weight loss in patients with diabetes and those at risk for developing the disease. © 2017 The Authors. Obesity published by Wiley Periodicals, Inc. on behalf of The Obesity Society (TOS).

  17. Coaching to Augment Mentoring to Achieve Faculty Diversity: A Randomized Controlled Trial

    PubMed Central

    Williams, Simon N.; Thakore, Bhoomi K.; McGee, Richard

    2015-01-01

    Purpose The Academy for Future Science Faculty (the Academy) is a novel coaching intervention for biomedical PhD students designed to address limitations in previous efforts to promote faculty diversity. Unlike traditional research mentoring, the Academy includes both group and individual coaching, coaches have no research or evaluation roles with the students, and it is based on social science theories. The authors present a qualitative case study of one of the coaching groups and provide statistical analyses indicating whether one year in the Academy effects students’ perceptions of the achievability and desirability of an academic career. Method The authors have tested (July 2012-July 2013), with Northwestern University ethical approval, the Academy via a longitudinal randomized controlled trial. Participants were 121 latter-stage biomedical PhD students. The authors collected data via questionnaires, interviews, and meeting recordings. Results The case study shows how group career coaching can effectively supplement traditional one-to-one research mentoring; provide new role models for underrepresented minority students; and provide theory-based lenses through which to engage in open conversations about race, gender, and science careers. Repeated-measures analysis of variances showed perceived achievability increased in the Academy group from baseline to 1-year follow-up (means, 5.75 vs. 6.39), but decreased in the control group (6.58 vs. 5.81). Perceived desirability decreased significantly less (P < 0.05) in the Academy group (7.00 vs. 6.36), than in the control group (7.83 vs. 5.97). Conclusions Early results suggest that an academic career-coaching model can effectively supplement traditional research mentoring and promote persistence towards academic careers. PMID:26675187

  18. Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using {sup 68}Ga-labeled nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kipritidis, John, E-mail: john.kipritidis@sydney.edu.au; Keall, Paul J.; Siva, Shankar

    Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metricsmore » model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant improvements in r{sup ¯} and d{sup ¯}{sub 20} (p < 0.05), with density scaled metrics also showing higher r{sup ¯} than for unscaled versions (p < 0.02). r{sup ¯} and d{sup ¯}{sub 20} were also sensitive to image quality, with statistically significant improvements using standard (as opposed to gated) PET images and with application of median filtering. Conclusions: The use of modified CT ventilation metrics, in conjunction with PET-Galligas and careful application of image filtering has resulted in improved correlation compared to earlier studies using nuclear medicine ventilation. However, CT ventilation and PET-Galligas do not always provide the same functional information. The authors have demonstrated that the agreement can improve for CT ventilation metrics incorporating a tissue density scaling, and also with increasing PET image quality. CT ventilation imaging has clear potential for imaging regional air volume change in the lung, and further development is warranted.« less

  19. OVERVIEW, PRACTICAL TIPS AND POTENTIAL PITFALLS OF USING AUTOMATIC EXPOSURE CONTROL IN CT: SIEMENS CARE DOSE 4D.

    PubMed

    Söderberg, Marcus

    2016-06-01

    Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. TH-C-18A-11: Investigating the Minimum Scan Parameters Required to Generate Free-Breathing Fast-Helical CT Scans Without Motion-Artifacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, D; Neylon, J; Dou, T

    Purpose: A recently proposed 4D-CT protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artifacts, which arise when tissue motion is greater than scan speed. This work identifies the minimum scanner parameters required to successfully generate free-breathing fast-helical scans without doubling-artifacts. Methods: 10 patients were imaged under free breathing conditions 25 times in alternating directions with a 64-slice CT scanner using a low dose fast helical protocol. A high temporal resolution (0.1s) 4D-CT was generated using a patient specific motionmore » model and patient breathing waveforms, and used as the input for a scanner simulation. Forward projections were calculated using helical cone-beam geometry (800 projections per rotation) and a GPU accelerated reconstruction algorithm was implemented. Various CT scanner detector widths and rotation times were simulated, and verified using a motion phantom. Doubling-artifacts were quantified in patient images using structural similarity maps to determine the similarity between axial slices. Results: Increasing amounts of doubling-artifacts were observed with increasing rotation times > 0.2s for 16×1mm slice scan geometry. No significant increase in doubling artifacts was observed for 64×1mm slice scan geometry up to 1.0s rotation time although blurring artifacts were observed >0.6s. Using a 16×1mm slice scan geometry, a rotation time of less than 0.3s (53mm/s scan speed) would be required to produce images of similar quality to a 64×1mm slice scan geometry. Conclusion: The current generation of 16 slice CT scanners, which are present in most Radiation Oncology departments, are not capable of generating free-breathing sorting-artifact-free images in the majority of patients. The next generation of CT scanners should be capable of at least 53mm/s scan speed in order to use a fast-helical 4D-CT protocol to generate a motion-artifact free 4D-CT. NIH R01CA096679.« less

  1. Evaluation of a Theory-Based Intervention Aimed at Improving Coaches' Recommendations on Sports Nutrition to Their Athletes.

    PubMed

    Jacob, Raphaëlle; Lamarche, Benoît; Provencher, Véronique; Laramée, Catherine; Valois, Pierre; Goulet, Claude; Drapeau, Vicky

    2016-08-01

    Coaches are a major source of nutrition information and influence for young athletes. Yet, most coaches do not have training in nutrition to properly guide their athletes. The aim of this study was to evaluate the effectiveness of an intervention aimed at improving the accuracy of coaches' recommendations on sports nutrition. This was a quasi-experimental study with a comparison group and an intervention group. Measurements were made at baseline, post-intervention, and after a 2-month follow-up period. Coaches' recommendations on sports nutrition during the follow-up period were recorded in a diary. High school coaches from various sports (n=41) were randomly assigned to a comparison group or an intervention group. Both groups attended two 90-minute sessions of a theory-based intervention targeting determinants of coaches' intention to provide recommendations on sports nutrition. The intervention group further received an algorithm that summarizes sports nutrition guidelines to help promote decision making on sports nutrition recommendations. Nutrition knowledge and accuracy of coaches' recommendations on sports nutrition. χ(2) analyses and t-tests were used to compare baseline characteristics; mixed and general linear model analyses were used to assess the change in response to the intervention and differences in behaviors, respectively. Coaches in the intervention vs comparison group provided more nutrition recommendations during the 2-month post-intervention period (mean number of recommendations per coach 25.7±22.0 vs 9.4±6.5, respectively; P=0.004) and recommendations had a greater accuracy (mean number of accurate recommendations per coach 22.4±19.9 [87.1%] vs 4.3±3.2 [46.1%], respectively; P<0.001). Knowledge was significantly increased post-intervention in both groups, but was maintained only in the intervention group during the 2-month follow-up (Pgroup*time=0.04). A theory-based intervention combined with a decision-making algorithm maintained coaches' sports nutrition knowledge level over time and helped them to provide more accurate recommendations on sports nutrition. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  2. [Computed tomography of the lungs. A step into the fourth dimension].

    PubMed

    Dinkel, J; Hintze, C; Rochet, N; Thieke, C; Biederer, J

    2009-08-01

    To discuss the techniques for four dimensional computed tomography of the lungs in tumour patients. The image acquisition in CT can be done using respiratory gating in two different ways: the helical or cine mode. In the helical mode, the couch moves continuously during image and respiratory signal acquisition. In the cine mode, the couch remains in the same position during at least one complete respiratory cycle and then moves to next position. The 4D images are either acquired prospectively or reconstructed retrospectively with dedicated algorithms in a freely selectable respiratory phase. The time information required for motion depiction in 4D imaging can be obtained with tolerable motion artefacts. Partial projection and stepladder-artifacts are occurring predominantly close to the diaphragm, where the displacement is most prominent. Due to the long exposure times, radiation exposure is significantly higher compared to a simple breathhold helical acquisition. Therefore, the use of 4D-CT is restricted to only specific indications (i.e. radiotherapy planning). 4D-CT of the lung allows evaluating the respiration-correlated displacement of lungs and tumours in space for radiotherapy planning.

  3. Coaching: a new model for academic and career achievement

    PubMed Central

    Deiorio, Nicole M.; Carney, Patricia A.; Kahl, Leslie E.; Bonura, Erin M.; Juve, Amy Miller

    2016-01-01

    Background Individualized education is emerging as an innovative model for physician training. This requires faculty coaching to guide learners’ achievements in academic performance, competency development, and career progression. In addition, coaching can foster self-reflection and self-monitoring using a data-guided approach to support lifelong learning. Context Coaching differs from mentoring or advising, and its application in medical education is novel. Because of this, definitions of the concept and the constructs of coaching as applied to medical education are needed to accurately assess the coaching relationship and coaching processes. These can then be linked to learner outcomes to inform how coaching serves as a modifier of academic and competency achievement and career satisfaction. Innovation We developed definitions and constructs for academic coaching in medical education based on review of existing education and non-education coaching literature. These constructs focus on 1) establishing relationship principles, 2) conducting learner assessments, 3) developing and implementing an action plan, and 4) assessing results and revising plans accordingly. Implication Coaching is emerging as an important construct in the context of medical education. This article lays the vital groundwork needed for evaluation of coaching programs aimed at producing outstanding physicians. PMID:27914193

  4. Coaching: a new model for academic and career achievement.

    PubMed

    Deiorio, Nicole M; Carney, Patricia A; Kahl, Leslie E; Bonura, Erin M; Juve, Amy Miller

    2016-01-01

    Individualized education is emerging as an innovative model for physician training. This requires faculty coaching to guide learners' achievements in academic performance, competency development, and career progression. In addition, coaching can foster self-reflection and self-monitoring using a data-guided approach to support lifelong learning. Coaching differs from mentoring or advising, and its application in medical education is novel. Because of this, definitions of the concept and the constructs of coaching as applied to medical education are needed to accurately assess the coaching relationship and coaching processes. These can then be linked to learner outcomes to inform how coaching serves as a modifier of academic and competency achievement and career satisfaction. We developed definitions and constructs for academic coaching in medical education based on review of existing education and non-education coaching literature. These constructs focus on 1) establishing relationship principles, 2) conducting learner assessments, 3) developing and implementing an action plan, and 4) assessing results and revising plans accordingly. Coaching is emerging as an important construct in the context of medical education. This article lays the vital groundwork needed for evaluation of coaching programs aimed at producing outstanding physicians.

  5. The Academy for Future Science Faculty: randomized controlled trial of theory-driven coaching to shape development and diversity of early-career scientists.

    PubMed

    Thakore, Bhoomi K; Naffziger-Hirsch, Michelle E; Richardson, Jennifer L; Williams, Simon N; McGee, Richard

    2014-08-02

    Approaches to training biomedical scientists have created a talented research community. However, they have failed to create a professional workforce that includes many racial and ethnic minorities and women in proportion to their representation in the population or in PhD training. This is particularly true at the faculty level. Explanations for the absence of diversity in faculty ranks can be found in social science theories that reveal processes by which individuals develop identities, experiences, and skills required to be seen as legitimate within the profession. Using the social science theories of Communities of Practice, Social Cognitive Career Theory, identity formation, and cultural capital, we have developed and are testing a novel coaching-based model to address some of the limitations of previous diversity approaches. This coaching intervention (The Academy for Future Science Faculty) includes annual in-person meetings of students and trained faculty Career Coaches, along with ongoing virtual coaching, group meetings and communication. The model is being tested as a randomized controlled trial with two cohorts of biomedical PhD students from across the U.S., one recruited at the start of their PhDs and one nearing completion. Stratification into the experimental and control groups, and to coaching groups within the experimental arms, achieved equal numbers of students by race, ethnicity and gender to the extent possible. A fundamental design element of the Academy is to teach and make visible the social science principles which highly influence scientific advancement, as well as acknowledging the extra challenges faced by underrepresented groups working to be seen as legitimate within the scientific communities. The strategy being tested is based upon a novel application of the well-established principles of deploying highly skilled coaches, selected and trained for their ability to develop talents of others. This coaching model is intended to be a complement, rather than a substitute, for traditional mentoring in biomedical research training, and is being tested as such.

  6. A Mobile Phone-Based Health Coaching Intervention for Weight Loss and Blood Pressure Reduction in a National Payer Population: A Retrospective Study

    PubMed Central

    Magana, Candy; Caballero Barajas, Karla

    2017-01-01

    Background The prevalence of obesity and associated metabolic conditions continue to be challenging and costly to address for health care systems; 71% of American adults were overweight, with 35% of men and 40% of women diagnosed with obesity in 2014. Digital health coaching is an innovative approach to decreasing the barriers of cost and accessibility of receiving health coaching for the prevention and management of chronic disease in overweight or obese individuals. Objective To evaluate the early impact of a mobile phone-based health coaching service on weight loss and blood pressure management in a commercially insured population. Methods This was a retrospective study using existing registry data from a pilot commercial collaboration between Vida Health and a large national insurance provider, which enrolled adult members who were overweight (body mass index >25 kg/m2) and able to engage in a mobile phone-based coaching intervention. Participants received 4 months of intensive health coaching via live video, phone, and text message through the Vida Health app. Participants were also provided with a wireless scale, pedometer, and blood pressure cuff. Of the 1012 enrolled, 763 (75.40%) participants had an initial weight upon enrollment and final weight between 3 and 5 months from enrollment; they served as our intervention group. There were 73 participants out of the 1012 (7.21%) who had weight data 4 months prior to and after Vida coaching, who served as the matched-pair control group. Results Participants in the intervention group lost an average of 3.23% total body weight (TBW) at 4 months of coaching and 28.6% (218/763) intervention participants achieved a clinically significant weight loss of 5% or more of TBW, with an average of 9.46% weight loss in this cohort. In the matched-pair control group, participants gained on average 1.81% TBW in 4 months without Vida coaching and lost, on average, 2.47% TBW after 4 months of Vida coaching, demonstrating a statistically significant difference of 4.28% in mean percentage weight change (P<.001). Among 151 intervention participants with blood pressure data, 112 (74.2%) had a baseline blood pressure that was above the goal (systolic blood pressure >120 mmHg); 55 out of 112 (49.1%) participants improved their blood pressure at 4 months by an entire hypertensive stage—as defined by the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. Conclusions Mobile phone app-based health coaching interventions can be an acceptable and effective means to promote weight loss and improve blood pressure management in overweight or obese individuals. Given the ubiquity of mobile phones, digital health coaching may be an innovative solution to decreasing barriers of access to much-needed weight management interventions for obesity. PMID:28596147

  7. 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography.

    PubMed

    Mediratta, Anuj; Addetia, Karima; Medvedofsky, Diego; Schneider, Robert J; Kruse, Eric; Shah, Atman P; Nathan, Sandeep; Paul, Jonathan D; Blair, John E; Ota, Takeyoshi; Balkhy, Husam H; Patel, Amit R; Mor-Avi, Victor; Lang, Roberto M

    2017-05-01

    With the increasing use of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS), computed tomography (CT) remains the standard for annulus sizing. However, 3D transesophageal echocardiography (TEE) has been an alternative in patients with contraindications to CT. We sought to (1) test the feasibility, accuracy, and reproducibility of prototype 3DTEE analysis software (Philips) for aortic annular measurements and (2) compare the new approach to the existing echocardiographic techniques. We prospectively studied 52 patients who underwent gated contrast CT, procedural 3DTEE, and TAVR. 3DTEE images were analyzed using novel semi-automated software designed for 3D measurements of the aortic root, which uses multiplanar reconstruction, similar to CT analysis. Aortic annulus measurements included area, perimeter, and diameter calculations from these measurements. The results were compared to CT-derived values. Additionally, 3D echocardiographic measurements (3D planimetry and mitral valve analysis software adapted for the aortic valve) were also compared to the CT reference values. 3DTEE image quality was sufficient in 90% of patients for aortic annulus measurements using the new software, which were in good agreement with CT (r-values: .89-.91) and small (<4%) inter-modality nonsignificant biases. Repeated measurements showed <10% measurements variability. The new 3D analysis was the more accurate and reproducible of the existing echocardiographic techniques. Novel semi-automated 3DTEE analysis software can accurately measure aortic annulus in patients with severe AS undergoing TAVR, in better agreement with CT than the existing methodology. Accordingly, intra-procedural TEE could potentially replace CT in patients where CT carries significant risk. © 2017, Wiley Periodicals, Inc.

  8. Talent development of high performance coaches in team sports in Ireland.

    PubMed

    Sherwin, Ian; Campbell, Mark J; Macintyre, Tadhg Eoghan

    2017-04-01

    Coaches are central to the development of the expert performer and similarly to continued lifelong participation in sport. Coaches are uniquely positioned to deliver specific technical and tactical instruction and mentoring programmes that support the psychological and social development of athletes in a challenging, goal-oriented and motivational environment. The current study aimed to qualitatively investigate current coach learning sources and coaches' educational backgrounds in team sports in Ireland. Coaches from five team sports in Ireland were asked to complete an online questionnaire. Subsequently male coaches (n = 19) from five team sports who completed the questionnaire and met the inclusion criteria were invited to attend a follow-up semi-structured interview. Inclusion criteria for coaches were that they possess at least 10 years' experience coaching their sport and were coaching more than 4 hours per week. Formal coach education does not meet the needs of high performance coaches who rely more on self-directed learning and coaching experience as their main sources of CPD. Although prior playing experience at a high level is both valuable and desirable, there are concerns about fast-tracking of ex-players into high performance coaching roles. Preferred sources of education and the best learning environment for coaches of team sports in Ireland are more informal than formal. Further research is needed to examine how this learning is applied in a practical manner by examining coaching behaviours and the impact it has on the athlete development process.

  9. Collegiate coaches' knowledge of the female athlete triad in relation to sport type.

    PubMed

    Frideres, Jillian E; Mottinger, Sue G; Palao, José M

    2016-03-01

    The purpose of this study was to determine what coaches of female athletes know about the three components of the female athlete triad with regard to type of sport coached and the characteristics of the coach. The sample consisted of 309 NCAA Division I coaches of female athletes in the sports of: sports with subjective scoring of performance (gymnastics and diving), low body weight sports (cross country and rowing), revealing or fitted clothing (volleyball and swimming), and other (soccer and basketball). An original, self-report questionnaire, and a 4-point Likert scale to measure confidence in answer was used. The variables were: knowledge, confidence, and coach's characteristics (coach's gender, degree held, years of experience in coaching females, continuing education participation specific to the triad and triad components, and type of sport coached). Coaches of low body weight sports scored significantly higher than both coaches of sports requiring fitted clothing and "other" sports in the overall score. They further had significantly more confidence in their answers than coaches of "other" sports. No significant differences in the overall score in any of the types of sport or total values were found regarding gender, experience, and degree. Coaches who had received training about the triad or its components scored significantly higher than coaches who did not receive training. The results demonstrated a lack of information among coaches and that participating in formative training can help to reduce this problem. The results found can help in the design of continuing education for coaches.

  10. Effect of re-coaching on self-injection of insulin in older diabetic patients - Impact of cognitive impairment.

    PubMed

    Omori, Keiko; Kawamura, Takahiko; Urata, Misako; Matsuura, Mayumi; Kusama, Minoru; Imamine, Rui; Watarai, Atsuko; Nakashima, Eitaro; Umemura, Toshitaka; Hotta, Nigishi

    2017-08-01

    We investigated the effect of re-coaching on self-injection of insulin and impact of cognitive function in 100 older diabetic patients. We examined patients on a variety of skills and knowledge regarding self-injection of insulin and evaluated the effect of re-coaching the patients after 3months and 4years. We also investigated the influence of cognitive impairment (CI) on coaching. Skills scores for self-injection of insulin and HbA1c improved significantly 3months after re-coaching. In 51 patients followed-up for 4years, skills scores were maintained during the 4years, while knowledge scores improved after 3months but then returned to the baseline level. In the group of patients with CI as determined by the Mini-Mental Status Examination, skills scores were similar to those in the group without CI, while knowledge scores were significantly lower as compared with those in the group without CI at any time point. Skills scores were maintained during the 4years regardless of CI. The present study showed that re-coaching in skills for self-injection of insulin was effective in improving and maintaining insulin treatment in older diabetic patients, even if patients had CI. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Physical Therapists, Telephone Coaches, and Patients With Knee Osteoarthritis: Qualitative Study About Working Together to Promote Exercise Adherence.

    PubMed

    Hinman, Rana S; Delany, Clare M; Campbell, Penelope K; Gale, Janette; Bennell, Kim L

    2016-04-01

    Integrated models of care are recommended for people with knee osteoarthritis (OA). Exercise is integral to management, yet exercise adherence is problematic. Telephone-based health coaching is an attractive adjunct to physical therapist-prescribed exercise that may improve adherence. Little is known about the perceptions and interpretations of physical therapists, telephone coaches, and patients engaged in this model of care. The purpose of this study was to explore how stakeholders (physical therapists, telephone coaches, and patients) experienced, and made sense of, being involved in an integrated program of physical therapist-supervised exercise and telephone coaching for people with knee OA. A cross-sectional qualitative design drawing from symbolic interactionism was used. Semistructured interviews with 10 physical therapists, 4 telephone coaches, and 6 patients with painful knee OA. Interviews were audiorecorded, transcribed, and analyzed using thematic analysis informed by grounded theory. Four themes emerged: (1) genuine interest and collaboration, (2) information and accountability, (3) program structure, and (4) roles and communication in teamwork. Patients reported they appreciated personalized, genuine interest from therapists and coaches and were aware of their complementary roles. A collaborative approach, with defined roles and communication strategies, was identified as important for effectiveness. All participants highlighted the importance of sharing information, monitoring, and being accountable to others. Coaches found the lack of face-to-face contact with patients hampered relationship building. Therapists and coaches referred to the importance of teamwork in delivering the intervention. The small number of physical therapists and telephone coaches who delivered the intervention may have been biased toward favorable experiences with the intervention and may not be representative of their respective professions. Integrated physical therapy and telephone coaching was perceived as beneficial by most stakeholders. Programs should be structured but have some flexibility to give therapists and coaches some freedom to adjust treatment to individual patient needs as required. Opportunities for visual communication between telephone coaches and patients could facilitate relationship building. © 2016 American Physical Therapy Association.

  12. Systematic review of coaching to enhance surgeons' operative performance.

    PubMed

    Min, Hyeyoun; Morales, Dianali Rivera; Orgill, Dennis; Smink, Douglas S; Yule, Steven

    2015-11-01

    There is increasing attention on the coaching of surgeons and trainees to improve performance but no comprehensive review on this topic. The purpose of this review is to summarize the quantity and the quality of studies involving surgical coaching methods and their effectiveness. We performed a systematic literature search through PubMed and PsychINFO by using predefined inclusion criteria. Evidence for main outcome categories was evaluated with the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system and the Medical Education Research Study Quality Instrument (MERSQI). Of a total 3,063 articles, 23 met our inclusion criteria; 4 randomized controlled trials and 19 observational studies. We categorized the articles into 4 groups on the basis of the outcome studied: perception, attitude and opinion; technical skills; nontechnical skills; and performance measures. Overall strength of evidence for each outcome groups was as follows: Perception, attitude, and opinion (Grading of Recommendations Assessment, Development, and Evaluation: Very Low, Medical Education Research Study Quality Instrument [MERSQI]: 10); technical skills (randomized controlled trials: High, 13.1; Observation studies: Very Low, 11.5); nontechnical skills (Very Low, 12.4) and performance measures (Very Low, 13.6). Simulation was the most used setting for coaching; more than half of the studies deployed an experienced surgeon as a coach and showed that coaching was effective. Surgical coaching interventions have a positive impact on learners' perception and attitudes, their technical and nontechnical skills, and performance measures. Evidence of impact on patient outcomes was limited, and the quality of research studies was variable. Despite this, our systematic review of different coaching interventions will benefit future coaching strategies and implementation to enhance operative performance. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Removal of Volatile Organics from Humidified Air Streams by Absorption.

    DTIC Science & Technology

    1987-12-01

    Type Comments Activated Carbons: SK-4 nut shell LCL coconut shell WV-B coal base CT coconut shell Specialty Carbons: Graphpac graphitized carbon area...Capacity, g/g Percentage Sorbent ( virgin ) (treated)D Change SK-4 0.114 0.117 +2.6 Carbosieve S-11 0.195 0.180 -7.7 Spherocarb 0.149 0.151 +1.3 CT...and WV-B with respect to their adsorption capacities. CT and SK-4 are both coconut -derived carbons produced by the same manufacturer. Differences

  14. TH-AB-BRA-04: Dosimetric Evaluation of MR-Guided HDR Brachytherapy Planning for Cervical Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamio, Y; Barkati, M; Beliveau-Nadeau, D

    2016-06-15

    Purpose: To perform a retrospective study on 16 patients that had both CT and T2-weighted MR scans done at first fraction using the Utrecht CT/MR applicator (Elekta Brachytherapy) in order to evaluate uncertainties associated with an MR-only planning workflow. Methods: MR-workflow uncertainties were classified in three categories: reconstruction, registration and contouring. A systematic comparison of the CT and MR contouring, manual reconstruction and optimization process was performed to evaluate the impact of these uncertainties on the recommended GEC ESTRO DVH parameters: D90% and V100% for HR-CTV as well as D2cc for bladder, rectum, sigmoid colon and small bowel. This comparisonmore » was done using the following four steps: 1. Catheter reconstruction done on MR images with original CT-plan contours and dwell times. 2. OAR contours adjusted on MR images with original CT-plan reconstruction and dwell times. 3. Both reconstruction and contours done on MR images with original CT-plan dwell times. 4. Entire MR-based workflow optimized dwell times reimported to the original CT-plan. Results: The MR-based reconstruction process showed average D2cc deviations of 4.5 ± 3.0%, 1.5 ± 2.0%, 2.5 ± 2.0% and 2.0 ± 1.0% for the bladder, rectum, sigmoid colon and small bowels respectively with a maximum of 10%, 6%, 6% and 4%. The HR-CTV’s D90% and V100% average deviations was found to be 4.0 ± 3.0%, and 2.0 ± 2.0% respectively with a maximum of 10% and 6%. Adjusting contours on MR-images was found to have a similar impact. Finally, the optimized MR-based workflow dwell times were found to still give acceptable plans when re-imported to the original CT-plan which validated the entire workflow. Conclusion: This work illustrates a systematic validation method for centers wanting to move towards an MR-only workflow. This work will be expanded to model based reconstruction, PD-weighted images and other types of applicators.« less

  15. Dosimetric evaluation of synthetic CT for magnetic resonance-only based radiotherapy planning of lung cancer.

    PubMed

    Wang, Hesheng; Chandarana, Hersh; Block, Kai Tobias; Vahle, Thomas; Fenchel, Matthias; Das, Indra J

    2017-06-26

    Interest in MR-only treatment planning for radiation therapy is growing rapidly with the emergence of integrated MRI/linear accelerator technology. The purpose of this study was to evaluate the feasibility of using synthetic CT images generated from conventional Dixon-based MRI scans for radiation treatment planning of lung cancer. Eleven patients who underwent whole-body PET/MR imaging following a PET/CT exam were randomly selected from an ongoing prospective IRB-approved study. Attenuation maps derived from the Dixon MR Images and atlas-based method was used to create CT data (synCT). Treatment planning for radiation treatment of lung cancer was optimized on the synCT and subsequently copied to the registered CT (planCT) for dose calculation. Planning target volumes (PTVs) with three sizes and four different locations in the lung were planned for irradiation. The dose-volume metrics comparison and 3D gamma analysis were performed to assess agreement between the synCT and CT calculated dose distributions. Mean differences between PTV doses on synCT and CT across all the plans were -0.1% ± 0.4%, 0.1% ± 0.5%, and 0.4% ± 0.5% for D95, D98 and D100, respectively. Difference in dose between the two datasets for organs at risk (OARs) had average differences of -0.14 ± 0.07 Gy, 0.0% ± 0.1%, and -0.1% ± 0.2% for maximum spinal cord, lung V20, and heart V40 respectively. In patient groups based on tumor size and location, no significant differences were observed in the PTV and OARs dose-volume metrics (p > 0.05), except for the maximum spinal-cord dose when the target volumes were located at the lung apex (p = 0.001). Gamma analysis revealed a pass rate of 99.3% ± 1.1% for 2%/2 mm (dose difference/distance to agreement) acceptance criteria in every plan. The synCT generated from Dixon-based MRI allows for dose calculation of comparable accuracy to the standard CT for lung cancer treatment planning. The dosimetric agreement between synCT and CT calculated doses warrants further development of a MR-only workflow for radiotherapy of lung cancer.

  16. Effects of different fresh-cut forages and their hays on feed intake, digestibility, heat production, and ruminal methane emission by Boer x Spanish goats.

    PubMed

    Puchala, R; Animut, G; Patra, A K; Detweiler, G D; Wells, J E; Varel, V H; Sahlu, T; Goetsch, A L

    2012-08-01

    Twenty-four yearling Boer × Spanish wethers were used to assess effects of different forages, either fresh (Exp. 1) or as hay (Exp. 2), on feed intake, digestibilities, heat production, and ruminal methane emission. Treatments were: 1) Sericea lespedeza (SER; Lespedeza cuneata), a legume high in condensed tannins (CT; 20% and 15% in fresh forage and hay, respectively), 2) SER supplemented with polyethylene glycol (SER-PEG; 25 g/d), 3) alfalfa (Medicago sativa), a legume low in CT (ALF), and 4) sorghum-sudangrass (Sorghum bicolor), a grass low in CT (GRASS). Experiments were 22 d, which included 16 d for acclimatization followed by a 6-d period for fecal and urine collection, and gas exchange measurement (last 2 d). Intake of OM was 867, 823, 694, and 691 g/d (SEM = 20.1) with fresh forage, and 806, 887, 681, and 607 g/d with hay for SER, SER-PEG, ALF, and GRASS, respectively (SEM = 46.6). Apparent total tract N digestion was greater for SER-PEG vs. SER (P < 0.001) with fresh forage (46.3%, 66.5%, 81.7%, and 73.2%; SEM = 1.71) and hay (49.7%, 71.4%, 65.4%, and 54.8% for SER, SER-PEG, ALF, and GRASS, respectively; SEM = 1.57). Intake of ME was similar among treatments with fresh forage (8.24, 8.06, 7.42, and 7.70 MJ/d; SEM = 0.434) and with hay was greater for SER-PEG than ALF (P < 0.03) and GRASS (P < 0.001) (8.63, 10.40, 8.15, and 6.74 MJ/d for SER, SER-PEG, ALF, and GRASS, respectively; SEM = 0.655). The number of ciliate protozoa in ruminal fluid was least for SER with fresh forage (P < 0.01) (9.8, 20.1, 21.0, and 33.6 × 10(5)/ml; SEM = 2.76) and hay (P < 0.02) (6.3, 11.4, 13.6, and 12.5 × 10(5)/ml for SER, SER-PEG, ALF, and GRASS, respectively; SEM = 1.43). Methane emission as a percentage of DE intake was lower (P < 0.01) for SER vs. ALF and GRASS with fresh forage (6.6, 8.3, 9.4, and 9.2%; SEM = 0.64) and hay (4.3, 4.9, 6.4, and 6.7% for SER, SER-PEG, ALF, and GRASS, respectively; SEM = 0.38). In summary, methane emission in this short-term experiment was similar between a legume and grass low in CT as fresh forage and hay. The CT in SER markedly decreased N digestibility and elicited a moderate decline in ruminal methane emission. Supplementation with PEG alleviated the effect of CT on N digestibility but not ruminal methane emission, presumably because of different modes of action. In conclusion, potential of using CT-containing forage as a means of decreasing ruminal methane emission requires further study, such as with longer feeding periods.

  17. Coaching the Debriefer: Peer Coaching to Improve Debriefing Quality in Simulation Programs.

    PubMed

    Cheng, Adam; Grant, Vincent; Huffman, James; Burgess, Gavin; Szyld, Demian; Robinson, Traci; Eppich, Walter

    2017-10-01

    Formal faculty development programs for simulation educators are costly and time-consuming. Peer coaching integrated into the teaching flow can enhance an educator's debriefing skills. We provide a practical guide for the who, what, when, where, why, and how of peer coaching for debriefing in simulation-based education. Peer coaching offers advantages such as psychological safety and team building, and it can benefit both the educator who is receiving feedback and the coach who is providing it. A feedback form for effective peer coaching includes the following: (1) psychological safety, (2) framework, (3) method/strategy, (4) content, (5) learner centeredness, (6) co-facilitation, (7) time management, (8) difficult situations, (9) debriefing adjuncts, and (10) individual style and experience. Institutional backing of peer coaching programs can facilitate implementation and sustainability. Program leaders should communicate the need and benefits, establish program goals, and provide assessment tools, training, structure, and evaluation to optimize chances of success.

  18. Development of a career coaching model for medical students.

    PubMed

    Hur, Yera

    2016-03-01

    Deciding on a future career path or choosing a career specialty is an important academic decision for medical students. The purpose of this study is to develop a career coaching model for medical students. This research was carried out in three steps. The first step was systematic review of previous studies. The second step was a need assessment of medical students. The third step was a career coaching model using the results acquired from the researched literature and the survey. The career coaching stages were defined as three big phases: The career coaching stages were defined as the "crystallization" period (Pre-medical year 1 and 2), "specification" period (medical year 1 and 2), and "implementation" period (medical year 3 and 4). The career coaching model for medical students can be used in programming career coaching contents and also in identifying the outcomes of career coaching programs at an institutional level.

  19. The reliability of a VISION COACH task as a measure of psychomotor skills.

    PubMed

    Xi, Yubin; Rosopa, Patrick J; Mossey, Mary; Crisler, Matthew C; Drouin, Nathalie; Kopera, Kevin; Brooks, Johnell O

    2014-10-01

    The VISION COACH™ interactive light board is designed to test and enhance participants' psychomotor skills. The primary goal of this study was to examine the test-retest reliability of the Full Field 120 VISION COACH task. One hundred eleven male and 131 female adult participants completed six trials where they responded to 120 randomly distributed lights displayed on the VISION COACH interactive light board. The mean time required for a participant to complete a trial was 101 seconds. Intraclass correlation coefficients, ranging from 0.962 to 0.987 suggest the VISION COACH Full Field 120 task was a reliable task. Cohen's d's of adjacent pairs of trials suggest learning effects did not negatively affect reliability after the third trial.

  20. Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Jia; Christner, Jodie A.; Duan Xinhui

    2012-11-15

    Purpose: To estimate attenuation using cross sectional CT images and scanned projection radiograph (SPR) images in a series of thorax and abdomen phantoms. Methods: Attenuation was quantified in terms of a water cylinder with cross sectional area of A{sub w} from both the CT and SPR images of abdomen and thorax phantoms, where A{sub w} is the area of a water cylinder that would absorb the same dose as the specified phantom. SPR and axial CT images were acquired using a dual-source CT scanner operated at 120 kV in single-source mode. To use the SPR image for estimating A{sub w},more » the pixel values of a SPR image were calibrated to physical water attenuation using a series of water phantoms. A{sub w} and the corresponding diameter D{sub w} were calculated using the derived attenuation-based methods (from either CT or SPR image). A{sub w} was also calculated using only geometrical dimensions of the phantoms (anterior-posterior and lateral dimensions or cross sectional area). Results: For abdomen phantoms, the geometry-based and attenuation-based methods gave similar results for D{sub w}. Using only geometric parameters, an overestimation of D{sub w} ranging from 4.3% to 21.5% was found for thorax phantoms. Results for D{sub w} using the CT image and SPR based methods agreed with each other within 4% on average in both thorax and abdomen phantoms. Conclusions: Either the cross sectional CT or SPR images can be used to estimate patient attenuation in CT. Both are more accurate than use of only geometrical information for the task of quantifying patient attenuation. The SPR based method requires calibration of SPR pixel values to physical water attenuation and this calibration would be best performed by the scanner manufacturer.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larner, J.

    In this interactive session, lung SBRT patient cases will be presented to highlight real-world considerations for ensuring safe and accurate treatment delivery. An expert panel of speakers will discuss challenges specific to lung SBRT including patient selection, patient immobilization techniques, 4D CT simulation and respiratory motion management, target delineation for treatment planning, online treatment alignment, and established prescription regimens and OAR dose limits. Practical examples of cases, including the patient flow thought the clinical process are presented and audience participation will be encouraged. This panel session is designed to provide case demonstration and review for lung SBRT in terms ofmore » (1) clinical appropriateness in patient selection, (2) strategies for simulation, including 4D and respiratory motion management, and (3) applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent, and (4) image guidance in treatment delivery. Learning Objectives: Understand the established requirements for patient selection in lung SBRT Become familiar with the various immobilization strategies for lung SBRT, including technology for respiratory motion management Understand the benefits and pitfalls of applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent determination for lung SBRT Understand established prescription regimes and OAR dose limits.« less

  2. Effects of Iterative Reconstruction Algorithms on Computer-assisted Detection (CAD) Software for Lung Nodules in Ultra-low-dose CT for Lung Cancer Screening.

    PubMed

    Nomura, Yukihiro; Higaki, Toru; Fujita, Masayo; Miki, Soichiro; Awaya, Yoshikazu; Nakanishi, Toshio; Yoshikawa, Takeharu; Hayashi, Naoto; Awai, Kazuo

    2017-02-01

    This study aimed to evaluate the effects of iterative reconstruction (IR) algorithms on computer-assisted detection (CAD) software for lung nodules in ultra-low-dose computed tomography (ULD-CT) for lung cancer screening. We selected 85 subjects who underwent both a low-dose CT (LD-CT) scan and an additional ULD-CT scan in our lung cancer screening program for high-risk populations. The LD-CT scans were reconstructed with filtered back projection (FBP; LD-FBP). The ULD-CT scans were reconstructed with FBP (ULD-FBP), adaptive iterative dose reduction 3D (AIDR 3D; ULD-AIDR 3D), and forward projected model-based IR solution (FIRST; ULD-FIRST). CAD software for lung nodules was applied to each image dataset, and the performance of the CAD software was compared among the different IR algorithms. The mean volume CT dose indexes were 3.02 mGy (LD-CT) and 0.30 mGy (ULD-CT). For overall nodules, the sensitivities of CAD software at 3.0 false positives per case were 78.7% (LD-FBP), 9.3% (ULD-FBP), 69.4% (ULD-AIDR 3D), and 77.8% (ULD-FIRST). Statistical analysis showed that the sensitivities of ULD-AIDR 3D and ULD-FIRST were significantly higher than that of ULD-FBP (P < .001). The performance of CAD software in ULD-CT was improved by using IR algorithms. In particular, the performance of CAD in ULD-FIRST was almost equivalent to that in LD-FBP. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. A Survey of Practicing Sleep Coaches.

    PubMed

    Ingram, David G; Mindell, Jodi A; Puzino, Kristina; Walters, Russel M

    2018-01-01

    Sleep coaches are individuals of various backgrounds who offer services to families struggling with behavioral childhood sleep problems. We conducted a survey of coaches to further elucidate scope of practice, practice patterns, geographic distribution, education, training, and beliefs regarding qualification requirements. A Web-based survey was completed by 142 individuals who identified as a sleep coach. Coaches were distributed across 17 countries and 5 continents. Overall, 65% of coaches served clients in countries beyond their home country. Within the United States, coaches were generally located in more affluent and well-educated zip codes near large metropolitan centers, 91% served clients beyond their home state, and 56% served clients internationally. Educational background varied across coaches (12% high school degree, 51% bachelor's degree, 32% master's degree, 2% doctoral degree, 1.5% JD degree). Few coaches (20%) were or had been licensed health care providers or carried malpractice insurance (38%). Coaches usually provided services for children < 4 months of age to about 6 years of age, and were much less likely to provide services for children with comorbid neurodevelopmental (32%) or significant medical disorders (19%). Coaches reported an average of 3 new and 6 total clients per week and working 20 hr per week on average. Most coaches (76%) felt that a formal sleep coach training program was the most important qualification for practice. These results highlight a diversity of background, training, and geographical distribution of sleep coaches, and may help inform discussions regarding guidelines for training and credentialing of sleep coaches.

  4. Effectiveness of the online weight reduction program KiloCoach™ and comparison with other evaluated commercial direct intervention and online programs.

    PubMed

    Longin, Rita; Grasse, Marina; Aspalter, Rosa; Waldherr, Karin

    2012-01-01

    Preliminary results indicated effectiveness of the online weight reduction program KiloCoach. The current study presents a large collection of user data and compares KiloCoach with other evaluated commercial weight loss programs. Furthermore, potential factors influencing the effectiveness of internet weight loss programs should be identified. 4,310 data sets of KiloCoach users were available, 3,150 of them were suitable for further analysis. 946 program users were considered completers (at least 60 days of continuous protocol). For comparison with other programs, different subsamples were drawn that matched to the inclusion criteria of reference studies. On average, KiloCoach overweight and obese completers lost 4.5 % of initial body weight. KiloCoach was as effective as the commercial program Weight Watchers® after 1 year (6.4% vs. 5.3% weight loss; p = 0.11) and 2 years (5.1% vs. 3.2% weight loss; p = 0.15). KiloCoach proved to be more effective than other online programs (Viktklubb, eDiets.com) as well as an in-person behavioral program, but less effective than Vtrim®, an online behavioral program providing intensive support. In comparison to reference programs, KiloCoach proved to be effective for weight reduction. The effect of online weight reduction programs seems to depend on methods and features applied.

  5. Prior Image Constrained Compressed Sensing Metal Artifact Reduction (PICCS-MAR): 2D and 3D Image Quality Improvement with Hip Prostheses at CT Colonography.

    PubMed

    Bannas, Peter; Li, Yinsheng; Motosugi, Utaroh; Li, Ke; Lubner, Meghan; Chen, Guang-Hong; Pickhardt, Perry J

    2016-07-01

    To assess the effect of the prior-image-constrained-compressed-sensing-based metal-artefact-reduction (PICCS-MAR) algorithm on streak artefact reduction and 2D and 3D-image quality improvement in patients with total hip arthroplasty (THA) undergoing CT colonography (CTC). PICCS-MAR was applied to filtered-back-projection (FBP)-reconstructed DICOM CTC-images in 52 patients with THA (unilateral, n = 30; bilateral, n = 22). For FBP and PICCS-MAR series, ROI-measurements of CT-numbers were obtained at predefined levels for fat, muscle, air, and the most severe artefact. Two radiologists independently reviewed 2D and 3D CTC-images and graded artefacts and image quality using a five-point-scale (1 = severe streak/no-diagnostic confidence, 5 = no streak/excellent image-quality, high-confidence). Results were compared using paired and unpaired t-tests and Wilcoxon signed-rank and Mann-Whitney-tests. Streak artefacts and image quality scores for FBP versus PICCS-MAR 2D-images (median: 1 vs. 3 and 2 vs. 3, respectively) and 3D images (median: 2 vs. 4 and 3 vs. 4, respectively) showed significant improvement after PICCS-MAR (all P < 0.001). PICCS-MAR significantly improved the accuracy of mean CT numbers for fat, muscle and the area with the most severe artefact (all P < 0.001). PICCS-MAR substantially reduces streak artefacts related to THA on DICOM images, thereby enhancing visualization of anatomy on 2D and 3D CTC images and increasing diagnostic confidence. • PICCS-MAR significantly reduces streak artefacts associated with total hip arthroplasty on 2D and 3D CTC. • PICCS-MAR significantly improves 2D and 3D CTC image quality and diagnostic confidence. • PICCS-MAR can be applied retrospectively to DICOM images from single-kVp CT.

  6. Reliability and Usefulness of Intraoperative 3-Dimensional Imaging by Mobile C-Arm With Flat-Panel Detector.

    PubMed

    Fujimori, Takahito; Iwasaki, Motoki; Nagamoto, Yukitaka; Kashii, Masafumi; Takao, Masaki; Sugiura, Tsuyoshi; Yoshikawa, Hideki

    2017-02-01

    Reliability and agreement study. To assess the reliability of intraoperative 3-dimensional imaging with a mobile C-arm (3D C-arm) equipped with a flat-panel detector. Pedicle screws are widely used in spinal surgery. Postoperative computed tomography (CT) is the most reliable method to detect screw misplacement. Recent advances in imaging devices have enabled surgeons to acquire 3D images of the spine during surgery. However, the reliability of these imaging devices is not known. A total of 203 screws were used in 22 consecutive patients who underwent surgery for scoliosis. Screw position was read twice with a 3D C-arm and twice with CT in a blinded manner by 2 independent observers. Screw positions were classified into 4 categories at every 2 mm and then into 2 simpler categories of acceptable or unacceptable. The degree of agreement with respect to screw positions between the double readings was evaluated by κ value. With unanimous agreement between 2 observers regarding postoperative CT readings considered the gold standard, the sensitivity of the 3D C-arm for determining screw misplacement was calculated. A total 804 readings were performed. For the 4-category classification, the mean κ value for the 2 interobserver readings was 0.52 for the 3D C-arm and 0.46 for CT. For the 2-category classification, the mean κ value for the 2 interobserver readings was 0.80 for the 3D C-arm and 0.66 for CT. The sensitivity, specificity, positive predictive value, and negative predictive value of intraoperative imaging with the 3D C-arm were 70%, 95%, 44%, and 98%, respectively. With respect to screws with perforation ≥4 mm, the sensitivity was 83%. No revision surgery was performed. Intraoperative imaging with a 3D C-arm was reliable for detecting screw misplacement and helpful in decreasing the rate of revision surgery for screw misplacement.

  7. TH-E-17A-01: Internal Respiratory Surrogate for 4D CT Using Fourier Transform and Anatomical Features

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hui, C; Suh, Y; Robertson, D

    Purpose: To develop a novel algorithm to generate internal respiratory signals for sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm extracted multiple time resolved features as potential respiratory signals. These features were taken from the 4D CT images and its Fourier transformed space. Several low-frequency locations in the Fourier space and selected anatomical features from the images were used as potential respiratory signals. A clustering algorithm was then used to search for the group of appropriate potential respiratory signals. The chosen signals were then normalized and averaged to form the final internal respiratory signal. Performance ofmore » the algorithm was tested in 50 4D CT data sets and results were compared with external signals from the real-time position management (RPM) system. Results: In almost all cases, the proposed algorithm generated internal respiratory signals that visibly matched the external respiratory signals from the RPM system. On average, the end inspiration times calculated by the proposed algorithm were within 0.1 s of those given by the RPM system. Less than 3% of the calculated end inspiration times were more than one time frame away from those given by the RPM system. In 3 out of the 50 cases, the proposed algorithm generated internal respiratory signals that were significantly smoother than the RPM signals. In these cases, images sorted using the internal respiratory signals showed fewer artifacts in locations corresponding to the discrepancy in the internal and external respiratory signals. Conclusion: We developed a robust algorithm that generates internal respiratory signals from 4D CT images. In some cases, it even showed the potential to outperform the RPM system. The proposed algorithm is completely automatic and generally takes less than 2 min to process. It can be easily implemented into the clinic and can potentially replace the use of external surrogates.« less

  8. Fieldcrest Cannon Workplace Literacy Modules for Supervisors. Alabama Partnership for Training.

    ERIC Educational Resources Information Center

    Alabama State Dept. of Education, Montgomery.

    This packet contains eight learning modules developed for use in Fieldcrest Cannon workplace literacy classes for supervisors. The modules cover the following topics: (1) coaching/communication; (2) coaching/communication and motivation; (3) communication skills; (4) training/coaching; (5) time management; (6) policy and procedures; (7) safety;…

  9. Seeing Is Believing: Using Imagery to Enhance Your Coaching

    ERIC Educational Resources Information Center

    Finch, Laura M.

    2011-01-01

    Imagery is a powerful sport psychology tool easily accessible to coaches. These reminders can help coaches improve their athletes' images and performance: (1) Create vivid and controllable images; (2) Use polysensory images and instructional cues, delivered, ideally, in real time; (3) Use internal and external perspectives; (4) Use imagery during…

  10. A Mobile Phone-Based Health Coaching Intervention for Weight Loss and Blood Pressure Reduction in a National Payer Population: A Retrospective Study.

    PubMed

    Mao, Alice Yuqing; Chen, Connie; Magana, Candy; Caballero Barajas, Karla; Olayiwola, J Nwando

    2017-06-08

    The prevalence of obesity and associated metabolic conditions continue to be challenging and costly to address for health care systems; 71% of American adults were overweight, with 35% of men and 40% of women diagnosed with obesity in 2014. Digital health coaching is an innovative approach to decreasing the barriers of cost and accessibility of receiving health coaching for the prevention and management of chronic disease in overweight or obese individuals. To evaluate the early impact of a mobile phone-based health coaching service on weight loss and blood pressure management in a commercially insured population. This was a retrospective study using existing registry data from a pilot commercial collaboration between Vida Health and a large national insurance provider, which enrolled adult members who were overweight (body mass index >25 kg/m2) and able to engage in a mobile phone-based coaching intervention. Participants received 4 months of intensive health coaching via live video, phone, and text message through the Vida Health app. Participants were also provided with a wireless scale, pedometer, and blood pressure cuff. Of the 1012 enrolled, 763 (75.40%) participants had an initial weight upon enrollment and final weight between 3 and 5 months from enrollment; they served as our intervention group. There were 73 participants out of the 1012 (7.21%) who had weight data 4 months prior to and after Vida coaching, who served as the matched-pair control group. Participants in the intervention group lost an average of 3.23% total body weight (TBW) at 4 months of coaching and 28.6% (218/763) intervention participants achieved a clinically significant weight loss of 5% or more of TBW, with an average of 9.46% weight loss in this cohort. In the matched-pair control group, participants gained on average 1.81% TBW in 4 months without Vida coaching and lost, on average, 2.47% TBW after 4 months of Vida coaching, demonstrating a statistically significant difference of 4.28% in mean percentage weight change (P<.001). Among 151 intervention participants with blood pressure data, 112 (74.2%) had a baseline blood pressure that was above the goal (systolic blood pressure >120 mmHg); 55 out of 112 (49.1%) participants improved their blood pressure at 4 months by an entire hypertensive stage-as defined by the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. Mobile phone app-based health coaching interventions can be an acceptable and effective means to promote weight loss and improve blood pressure management in overweight or obese individuals. Given the ubiquity of mobile phones, digital health coaching may be an innovative solution to decreasing barriers of access to much-needed weight management interventions for obesity. ©Alice Yuqing Mao, Connie Chen, Candy Magana, Karla Caballero Barajas, J Nwando Olayiwola. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 08.06.2017.

  11. Automated Voxel-Based Analysis of Volumetric Dynamic Contrast-Enhanced CT Data Improves Measurement of Serial Changes in Tumor Vascular Biomarkers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coolens, Catherine, E-mail: catherine.coolens@rmp.uhn.on.ca; Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario

    2015-01-01

    Objectives: Development of perfusion imaging as a biomarker requires more robust methodologies for quantification of tumor physiology that allow assessment of volumetric tumor heterogeneity over time. This study proposes a parametric method for automatically analyzing perfused tissue from volumetric dynamic contrast-enhanced (DCE) computed tomography (CT) scans and assesses whether this 4-dimensional (4D) DCE approach is more robust and accurate than conventional, region-of-interest (ROI)-based CT methods in quantifying tumor perfusion with preliminary evaluation in metastatic brain cancer. Methods and Materials: Functional parameter reproducibility and analysis of sensitivity to imaging resolution and arterial input function were evaluated in image sets acquired from amore » 320-slice CT with a controlled flow phantom and patients with brain metastases, whose treatments were planned for stereotactic radiation surgery and who consented to a research ethics board-approved prospective imaging biomarker study. A voxel-based temporal dynamic analysis (TDA) methodology was used at baseline, at day 7, and at day 20 after treatment. The ability to detect changes in kinetic parameter maps in clinical data sets was investigated for both 4D TDA and conventional 2D ROI-based analysis methods. Results: A total of 7 brain metastases in 3 patients were evaluated over the 3 time points. The 4D TDA method showed improved spatial efficacy and accuracy of perfusion parameters compared to ROI-based DCE analysis (P<.005), with a reproducibility error of less than 2% when tested with DCE phantom data. Clinically, changes in transfer constant from the blood plasma into the extracellular extravascular space (K{sub trans}) were seen when using TDA, with substantially smaller errors than the 2D method on both day 7 post radiation surgery (±13%; P<.05) and by day 20 (±12%; P<.04). Standard methods showed a decrease in K{sub trans} but with large uncertainty (111.6 ± 150.5) %. Conclusions: Parametric voxel-based analysis of 4D DCE CT data resulted in greater accuracy and reliability in measuring changes in perfusion CT-based kinetic metrics, which have the potential to be used as biomarkers in patients with metastatic brain cancer.« less

  12. Developing a Scale of Perception of Sexual Abuse in Youth Sports (SPSAYS)

    ERIC Educational Resources Information Center

    Baker, Thomas A., III.; Byon, Kevin K.

    2014-01-01

    A scale was developed to measure perceptions of sexual abuse in youth sports by assessing (a) the perceived prevalence of sexual abuse committed by pedophilic youth sport coaches, (b) the perceived likelihood that a coach is a pedophile, (c) perceptions on how youth sport organizations should manage the risk of pedophilia, and (d) media influence…

  13. Effects of Training and Competition Load on Neuromuscular Recovery, Testosterone, Cortisol, and Match Performance During a Season of Professional Football

    PubMed Central

    Rowell, Amber E.; Aughey, Robert J.; Hopkins, William G.; Esmaeili, Alizera; Lazarus, Brendan H.; Cormack, Stuart J.

    2018-01-01

    Introduction: Training load and other measures potentially related to match performance are routinely monitored in team-sport athletes. The aim of this research was to examine the effect of training load on such measures and on match performance during a season of professional football. Materials and Methods: Training load was measured daily as session duration times perceived exertion in 23 A-League football players. Measures of exponentially weighted cumulative training load were calculated using decay factors representing time constants of 3–28 days. Players performed a countermovement jump for estimation of a measure of neuromuscular recovery (ratio of flight time to contraction time, FT:CT), and provided a saliva sample for measurement of testosterone and cortisol concentrations 1-day prior to each of 34 matches. Match performance was assessed via ratings provided by five coaching and fitness staff on a 5-point Likert scale. Effects of training load on FT:CT, hormone concentrations and match performance were modeled as quadratic predictors and expressed as changes in the outcome measure for a change in the predictor of one within-player standard deviation (1 SD) below and above the mean. Changes in each of five playing positions were assessed using standardization and magnitude-based inference. Results: The largest effects of training were generally observed in the 3- to 14-day windows. Center defenders showed a small reduction in coach rating when 14-day a smoothed load increased from −1 SD to the mean (-0.31, ±0.15; mean, ±90% confidence limits), whereas strikers and wide midfielders displayed a small increase in coach rating when load increased 1 SD above the mean. The effects of training load on FT:CT were mostly unclear or trivial, but effects of training load on hormones included a large increase in cortisol (102, ±58%) and moderate increase in testosterone (24, ±18%) in center defenders when 3-day smoothed training load increased 1 SD above the mean. A 1 SD increase in training load above the mean generally resulted in substantial reductions in testosterone:cortisol ratio. Conclusion: The effects of recent training on match performance and hormones in A-League football players highlight the importance of position-specific monitoring and training. PMID:29930514

  14. 3D SPECT/CT fusion using image data projection of bone SPECT onto 3D volume-rendered CT images: feasibility and clinical impact in the diagnosis of bone metastasis.

    PubMed

    Ogata, Yuji; Nakahara, Tadaki; Ode, Kenichi; Matsusaka, Yohji; Katagiri, Mari; Iwabuchi, Yu; Itoh, Kazunari; Ichimura, Akira; Jinzaki, Masahiro

    2017-05-01

    We developed a method of image data projection of bone SPECT into 3D volume-rendered CT images for 3D SPECT/CT fusion. The aims of our study were to evaluate its feasibility and clinical usefulness. Whole-body bone scintigraphy (WB) and SPECT/CT scans were performed in 318 cancer patients using a dedicated SPECT/CT systems. Volume data of bone SPECT and CT were fused to obtain 2D SPECT/CT images. To generate our 3D SPECT/CT images, colored voxel data of bone SPECT were projected onto the corresponding location of the volume-rendered CT data after a semi-automatic bone extraction. Then, the resultant 3D images were blended with conventional volume-rendered CT images, allowing to grasp the three-dimensional relationship between bone metabolism and anatomy. WB and SPECT (WB + SPECT), 2D SPECT/CT fusion, and 3D SPECT/CT fusion were evaluated by two independent reviewers in the diagnosis of bone metastasis. The inter-observer variability and diagnostic accuracy in these three image sets were investigated using a four-point diagnostic scale. Increased bone metabolism was found in 744 metastatic sites and 1002 benign changes. On a per-lesion basis, inter-observer agreements in the diagnosis of bone metastasis were 0.72 for WB + SPECT, 0.90 for 2D SPECT/CT, and 0.89 for 3D SPECT/CT. Receiver operating characteristic analyses for the diagnostic accuracy of bone metastasis showed that WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT had an area under the curve of 0.800, 0.983, and 0.983 for reader 1, 0.865, 0.992, and 0.993 for reader 2, respectively (WB + SPECT vs. 2D or 3D SPECT/CT, p < 0.001; 2D vs. 3D SPECT/CT, n.s.). The durations of interpretation of WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT images were 241 ± 75, 225 ± 73, and 182 ± 71 s for reader 1 and 207 ± 72, 190 ± 73, and 179 ± 73 s for reader 2, respectively. As a result, it took shorter time to read 3D SPECT/CT images than 2D SPECT/CT (p < 0.0001) or WB + SPECT images (p < 0.0001). 3D SPECT/CT fusion offers comparable diagnostic accuracy to 2D SPECT/CT fusion. The visual effect of 3D SPECT/CT fusion facilitates reduction of reading time compared to 2D SPECT/CT fusion.

  15. Liver metastases from prostate cancer at 11C-Choline PET/CT: a multicenter, retrospective analysis.

    PubMed

    Ghedini, Pietro; Bossert, I; Zanoni, L; Ceci, F; Graziani, T; Castellucci, P; Ambrosini, V; Massari, F; Nobili, E; Melotti, B; Musto, A; Zoboli, S; Antunovic, L; Kirienko, M; Chiti, A; Mosconi, C; Ardizzoni, A; Golfieri, R; Fanti, S; Nanni, C

    2018-05-01

    During our daily clinical practice using 11C-Choline PET/CT for restaging patients affected by relapsing prostate cancer (rPCa) we noticed an unusual but significant occurrence of hypodense hepatic lesions with a different tracer uptake. Thus, we decided to evaluate the possible correlation between rPCa and these lesions as possible hepatic metastases. We retrospectively enrolled 542 patients diagnosed with rPCa in biochemical relapse after a radical treatment (surgery and/or radiotherapy). Among these, patients with a second tumor or other benign hepatic diseases were excluded. All patients underwent 11C-Choline PET/CT during the standard restaging workup of their disease. We analyzed CT images to evaluate the presence of hypodense lesions and PET images to identify the relative tracer uptake. In accordance to the subsequent oncological history, five clinical scenarios were recognized [Table 1]: normal low dose CT (ldCT) and normal tracer distribution (Group A); evidence of previously unknown hepatic round hypodense areas at ldCT with normal rim uptake (Group B); evidence of previously known hepatic round hypodense areas at ldCT stable over time and with normal rim uptake (Group C); evidence of previously known hepatic round hypodense areas at ldCT, in a previous PET/CT scan, with or without rim uptake and significantly changing over time in terms of size and/or uptake (Group D); evidence of hepatic round hypodense areas at ldCT with or without rim uptake confirmed as prostate liver metastases by histopathology, triple phase ceCT, ce-ultra sound (CEUS) and clinical/biochemical evaluation (Group E). We evaluated the correlation with PSA level at time of scan, rim SUVmax and association with local relapse or non-hepatic metastases (lymph nodes, bone, other parenchyma). Five hundred and forty-two consecutive patients were retrospectively enrolled. In 140 of the 542 patients more than one 11C-choline PET/CT had been performed. A total of 742 11C-Choline PET/CT scans were analyzed. Of the 542 patients enrolled, 456 (84.1%) had a normal appearance of the liver both at ldCT and PET (Group A). 19/542 (3,5%) belonged to Group B, 13/542 (2.4%) to Group C, 37/542 (6.8%) to Group D and 18/542 (3.3%) to Group E. Mean SUVmax of the rim was: 4.5 for Group B; 4.2 for Group C; 4.8 for Group D; 5.9 for Group E. Mean PSA level was 5.27 for Group A, 7.9 for Group B, 10.04 for Group C, 10.01 for Group D, 9.36 for Group E. Presence of positive findings at 11C-Choline PET/CT in any further anatomical area (local relapse, lymph node, bone, other extra hepatic sites) correlated with an higher PSA (p = 0.0285). In both the univariate and multivariate binary logistic regression analyses. PSA, SUVmax of the rim, local relapse, positive nodes were not associated to liver mets (Groups D-E) (p > 0.05). On the contrary, a significant correlation was found between the presence of liver metG (group D-E) and bone lesions (p= 0.00193). Our results indicate that liver metastases in relapsing prostate cancer may occur frequently. The real incidence evaluation needs more investigations. In this case and despite technical limitations, Choline PET/CT shows alterations of tracer distribution within the liver that could eventually be mistaken for simple cysts but can be suspected when associated to high trigger PSA, concomitant bone lesions or modification over time. In this clinical setting an accurate analysis of liver tracer distribution (increased or decreased uptake) by the nuclear medicine physician is, therefore, mandatory.

  16. Comparison of different patient positioning strategies to minimize shoulder girdle artifacts in head and neck CT.

    PubMed

    Wirth, Stefan; Meindl, Thomas; Treitl, Marcus; Pfeifer, Klaus-Jürgen; Reiser, Maximilian

    2006-08-01

    The purpose of this study was to analyze different patient positioning strategies for minimizing artifacts of the shoulder girdle in head and neck CT. Standardized CT examinations of three positioning groups were compared (P: patients pushed their shoulders downwards; D: similar optimization by a pulling device; N: no particular positioning optimization). Parameters analyzed were the length of the cervical spine not being superimposed by the shoulder girdle as well as noise in the supraclavicular space. In groups P and D, the portion of the cervical spine not superimposed was significantly larger than in group N (P: 10.4 cm; D: 10.6 cm; N: 8.5 cm). At the supraclavicular space, noise decreased significantly (P: 12.5 HU; D: 12.1 HU; N: 17.7 HU). No significant differences between the two position-optimized groups (P and D) were detected. Optimized shoulder positioning by the patient increases image quality in CT head and neck imaging. The use of a pulling device offers no additional advantages.

  17. The impact of computed tomography slice thickness on the assessment of stereotactic, 3D conformal and intensity-modulated radiotherapy of brain tumors.

    PubMed

    Caivano, R; Fiorentino, A; Pedicini, P; Califano, G; Fusco, V

    2014-05-01

    To evaluate radiotherapy treatment planning accuracy by varying computed tomography (CT) slice thickness and tumor size. CT datasets from patients with primary brain disease and metastatic brain disease were selected. Tumor volumes ranging from about 2.5 to 100 cc and CT scan at different slice thicknesses (1, 2, 4, 6 and 10 mm) were used to perform treatment planning (1-, 2-, 4-, 6- and 10-CT, respectively). For any slice thickness, a conformity index (CI) referring to 100, 98, 95 and 90 % isodoses and tumor size was computed. All the CI and volumes obtained were compared to evaluate the impact of CT slice thickness on treatment plans. The smallest volumes reduce significantly if defined on 1-CT with respect to 4- and 6-CT, while the CT slice thickness does not affect target definition for the largest volumes. The mean CI for all the considered isodoses and CT slice thickness shows no statistical differences when 1-CT is compared to 2-CT. Comparing the mean CI of 1- with 4-CT and 1- with 6-CT, statistical differences appear only for the smallest volumes with respect to 100, 98 and 95 % isodoses-the CI for 90 % isodose being not statistically significant for all the considered PTVs. The accuracy of radiotherapy tumor volume definition depends on CT slice thickness. To achieve a better tumor definition and dose coverage, 1- and 2-CT would be suitable for small targets, while 4- and 6-CT are suitable for the other volumes.

  18. Mid-Ventilation Concept for Mobile Pulmonary Tumors: Internal Tumor Trajectory Versus Selective Reconstruction of Four-Dimensional Computed Tomography Frames Based on External Breathing Motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guckenberger, Matthias; Wilbert, Juergen; Krieger, Thomas

    2009-06-01

    Purpose: To evaluate the accuracy of direct reconstruction of mid-ventilation and peak-phase four-dimensional (4D) computed tomography (CT) frames based on the external breathing signal. Methods and Materials: For 11 patients with 15 pulmonary targets, a respiration-correlated CT study (4D CT) was acquired for treatment planning. After retrospective time-based sorting of raw projection data and reconstruction of eight CT frames equally distributed over the breathing cycle, mean tumor position (P{sub mean}), mid-ventilation frame, and breathing motion were evaluated based on the internal tumor trajectory. Analysis of the external breathing signal (pressure sensor around abdomen) with amplitude-based sorting of projections was performedmore » for direct reconstruction of the mid-ventilation frame and frames at peak phases of the breathing cycle. Results: On the basis of the eight 4D CT frames equally spaced in time, tumor motion was largest in the craniocaudal direction, with 12 {+-} 7 mm on average. Tumor motion between the two frames reconstructed at peak phases was not different in the craniocaudal and anterior-posterior directions but was systematically smaller in the left-right direction by 1 mm on average. The 3-dimensional distance between P{sub mean} and the tumor position in the mid-ventilation frame based on the internal tumor trajectory was 1.2 {+-} 1 mm. Reconstruction of the mid-ventilation frame at the mean amplitude position of the external breathing signal resulted in tumor positions 2.0 {+-} 1.1 mm distant from P{sub mean}. Breathing-induced motion artifacts in mid-ventilation frames caused negligible changes in tumor volume and shape. Conclusions: Direct reconstruction of the mid-ventilation frame and frames at peak phases based on the external breathing signal was reliable. This makes the reconstruction of only three 4D CT frames sufficient for application of the mid-ventilation technique in clinical practice.« less

  19. Prognostic Value and Reproducibility of Pretreatment CT Texture Features in Stage III Non-Small Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fried, David V.; Graduate School of Biomedical Sciences, The University of Texas Health Science Center at Houston, Houston, Texas; Tucker, Susan L.

    2014-11-15

    Purpose: To determine whether pretreatment CT texture features can improve patient risk stratification beyond conventional prognostic factors (CPFs) in stage III non-small cell lung cancer (NSCLC). Methods and Materials: We retrospectively reviewed 91 cases with stage III NSCLC treated with definitive chemoradiation therapy. All patients underwent pretreatment diagnostic contrast enhanced computed tomography (CE-CT) followed by 4-dimensional CT (4D-CT) for treatment simulation. We used the average-CT and expiratory (T50-CT) images from the 4D-CT along with the CE-CT for texture extraction. Histogram, gradient, co-occurrence, gray tone difference, and filtration-based techniques were used for texture feature extraction. Penalized Cox regression implementing cross-validation wasmore » used for covariate selection and modeling. Models incorporating texture features from the 33 image types and CPFs were compared to those with models incorporating CPFs alone for overall survival (OS), local-regional control (LRC), and freedom from distant metastases (FFDM). Predictive Kaplan-Meier curves were generated using leave-one-out cross-validation. Patients were stratified based on whether their predicted outcome was above or below the median. Reproducibility of texture features was evaluated using test-retest scans from independent patients and quantified using concordance correlation coefficients (CCC). We compared models incorporating the reproducibility seen on test-retest scans to our original models and determined the classification reproducibility. Results: Models incorporating both texture features and CPFs demonstrated a significant improvement in risk stratification compared to models using CPFs alone for OS (P=.046), LRC (P=.01), and FFDM (P=.005). The average CCCs were 0.89, 0.91, and 0.67 for texture features extracted from the average-CT, T50-CT, and CE-CT, respectively. Incorporating reproducibility within our models yielded 80.4% (±3.7% SD), 78.3% (±4.0% SD), and 78.8% (±3.9% SD) classification reproducibility in terms of OS, LRC, and FFDM, respectively. Conclusions: Pretreatment tumor texture may provide prognostic information beyond that obtained from CPFs. Models incorporating feature reproducibility achieved classification rates of ∼80%. External validation would be required to establish texture as a prognostic factor.« less

  20. Comparison of 3 different postimplant dosimetry methods following permanent {sup 125}I prostate seed brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcu, Loredana G., E-mail: loredana@marcunet.com; Faculty of Science, University of Oradea; School of Chemistry and Physics, University of Adelaide, South Australia

    2013-10-01

    Postimplant dosimetry (PID) after Iodine-125 ({sup 125}I) implant of the prostate should offer a reliable qualitative assessment. So far, there is no consensus regarding the optimum PID method, though the latest literature is in favor of magnetic resonance imaging (MRI). This study aims to simultaneously compare 3 PID techniques: (1) MRI-computed tomography (CT) fusion; (2) ultrasound (US)-CT fusion; and (3) manual target delineation on CT. The study comprised 10 patients with prostate cancer. CT/MR scans with urinary catheters in place for PID were done either on day 0 or day 1 postimplantation. The main parameter evaluated and compared among methodsmore » was target D90. The results show that CT-based D90s are lower than US-CT D90s (median difference,−6.85%), whereas MR-CT PID gives higher D90 than US-CT PID (median difference, 4.25%). Manual contouring on CT images tends to overestimate the prostate volume compared with transrectal ultrasound (TRUS) (median difference, 23.33%), whereas on US images the target is overestimated compared with MR-based contouring (median difference, 13.25%). Although there are certain differences among the results given by various PID techniques, the differences are statistically insignificant for this small group of patients. Any dosimetric comparison between 2 PID techniques should also account for the limitations of each technique, to allow for an accurate quantification of data. Given that PID after permanent radioactive seed implant is mandatory for quality assurance, any imaging method–based PID (MR-CT, US-CT, and CT) available in a radiotherapy department can be indicative of the quality of the procedure.« less

  1. Wide field of view CT and acromioclavicular joint instability: A technical innovation.

    PubMed

    Dyer, David R; Troupis, John M; Kamali Moaveni, Afshin

    2015-06-01

    A 21-year-old female with a traumatic shoulder injury is investigated and managed for symptoms relating to this injury. Pathology at the acromioclavicular joint is detected clinically; however, clinical examination and multiple imaging modalities do not reach a unified diagnosis on the grading of this acromioclavicular joint injury. When management appropriate to that suggested injury grading fail to help the patient's symptoms, further investigation methods were utilised. Wide field of view, dynamic CT (4D CT) is conducted on the patient's affected shoulder using a 320 × 0.5 mm detector multislice CT. Scans were conducted with a static table as the patient completed three movements of the affected shoulder. Capturing multiple data sets per second over a z-axis of 16 cm, measurements of the acromioclavicular joint were made, to show dynamic changes at the joint. Acromioclavicular (AC) joint translations were witnessed in three planes (a previously unrecognised pathology in the grading of acromioclavicular joint injuries). Translation in multiple planes was also not evident on careful clinical examination of this patient. AC joint width, anterior-posterior translation, superior-inferior translation and coracoclavicular width were measured with planar reconstructions while volume-rendered images and dynamic sequences aiding visual understanding of the pathology. Wide field of view dynamic CT (4D CT) is an accurate and quick modality to diagnose complex acromioclavicular joint injury. It provides dynamic information that no other modality can; 4D CT shows future benefits for clinical approach to diagnosis and management of acromioclavicular joint injury, and other musculoskeletal pathologies. © 2015 The Royal Australian and New Zealand College of Radiologists.

  2. Development of a career coaching model for medical students

    PubMed Central

    Hur, Yera

    2016-01-01

    Purpose: Deciding on a future career path or choosing a career specialty is an important academic decision for medical students. The purpose of this study is to develop a career coaching model for medical students. Methods: This research was carried out in three steps. The first step was systematic review of previous studies. The second step was a need assessment of medical students. The third step was a career coaching model using the results acquired from the researched literature and the survey. Results: The career coaching stages were defined as three big phases: The career coaching stages were defined as the “crystallization” period (Pre-medical year 1 and 2), “specification” period (medical year 1 and 2), and “implementation” period (medical year 3 and 4). Conclusion: The career coaching model for medical students can be used in programming career coaching contents and also in identifying the outcomes of career coaching programs at an institutional level. PMID:26867586

  3. Internal respiratory surrogate in multislice 4D CT using a combination of Fourier transform and anatomical features

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hui, Cheukkai; Suh, Yelin; Robertson, Daniel

    Purpose: The purpose of this study was to develop a novel algorithm to create a robust internal respiratory signal (IRS) for retrospective sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm combines information from the Fourier transform of the CT images and from internal anatomical features to form the IRS. The algorithm first extracts potential respiratory signals from low-frequency components in the Fourier space and selected anatomical features in the image space. A clustering algorithm then constructs groups of potential respiratory signals with similar temporal oscillation patterns. The clustered group with the largest number of similar signalsmore » is chosen to form the final IRS. To evaluate the performance of the proposed algorithm, the IRS was computed and compared with the external respiratory signal from the real-time position management (RPM) system on 80 patients. Results: In 72 (90%) of the 4D CT data sets tested, the IRS computed by the authors’ proposed algorithm matched with the RPM signal based on their normalized cross correlation. For these data sets with matching respiratory signals, the average difference between the end inspiration times (Δt{sub ins}) in the IRS and RPM signal was 0.11 s, and only 2.1% of Δt{sub ins} were more than 0.5 s apart. In the eight (10%) 4D CT data sets in which the IRS and the RPM signal did not match, the average Δt{sub ins} was 0.73 s in the nonmatching couch positions, and 35.4% of them had a Δt{sub ins} greater than 0.5 s. At couch positions in which IRS did not match the RPM signal, a correlation-based metric indicated poorer matching of neighboring couch positions in the RPM-sorted images. This implied that, when IRS did not match the RPM signal, the images sorted using the IRS showed fewer artifacts than the clinical images sorted using the RPM signal. Conclusions: The authors’ proposed algorithm can generate robust IRSs that can be used for retrospective sorting of 4D CT data. The algorithm is completely automatic and requires very little processing time. The algorithm is cost efficient and can be easily adopted for everyday clinical use.« less

  4. The Impact of Literacy Coaches: What Teachers Value and How Teachers Change

    ERIC Educational Resources Information Center

    Vanderburg, Michelle; Stephens, Diane

    2010-01-01

    In order to better understand literacy coaches' impact on teachers, the authors analyzed interviews with 35 teachers who participated in a statewide professional development effort, the South Carolina Reading Initiative. For 3 years, literacy coaches facilitated bimonthly study groups for teachers and spent 4 days a week in teachers' classrooms…

  5. 41 CFR 301-10.123 - When may I use other than coach-class airline accommodations?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to: (i) Use of coach-class accommodations would endanger your life or Government property; (ii) You... coach-class accommodations would endanger your life or Government property; (ii) You are an agent on... sanitation or health standards; (4) Regularly scheduled flights between origin/destination points (including...

  6. Emerging Issues and Opportunities Prospective Analysis.

    ERIC Educational Resources Information Center

    Peter, Sharlene A.

    This paper discusses 14 issues related to gender equity in intercollegiate athletics, including: (1) the cost dilemma, in which institutions have to cut men's sports to introduce women's sports; (2) equal pay for the coaches of men's and women's teams; (3) the gender of coaches, namely men coaching women's teams; (4) peer harassment among…

  7. Use of an Objective Structured Clinical Examination in Clinical Nurse Specialist Education.

    PubMed

    Cuevas, Heather E; Timmerman, Gayle M

    2016-01-01

    Helping patients maximize their potential using expert coaching to facilitate lifestyle change is an important practice area for clinical nurse specialists (CNSs). The purpose is to determine the usefulness of objective structured clinical examinations (OSCEs) for evaluating CNS students' coaching competencies in the context of facilitating lifestyle change. Despite the use of OSCEs to assess competencies in clinical skills (eg, performance of procedures, decision making), its potential for evaluating coaching competencies for lifestyle change has not been demonstrated. We developed 4 OSCEs dealing with coaching patients in exercise, weight loss, stress reduction, or nonpharmacologic management of hyperlipidemia. Evaluation criteria included (1) approach to the patient, (2) information gathering, (3) motivational interviewing, and (4) management (medical and behavioral strategies). Student performance ranged from highly organized with proficient coaching skills to disorganized and focused solely on clinical management and prescriptive communication. Student responses were positive. Objective structured clinical examinations were highly useful for evaluating CNS students' coaching competencies for lifestyle change. Using OSCEs early in the semester to provide students feedback on their performance and again at the end to determine improvement optimizes use of this teaching strategy.

  8. The Influence of Match-Day Napping in Elite Female Netball Athletes.

    PubMed

    O'Donnell, Shannon; Beaven, Christopher M; Driller, Matthew

    2018-03-15

    To assess the effect of match-day napping and duration of naps on perceptual and performance indices in elite female netball players over two consecutive netball seasons. Fourteen elite female netball athletes (mean ± SD; age = 23 ± 6 yr) participated in an observational study over 26 competition matches. On each match day, athletes provided information on their napping habits, perceived energy levels, and then performed 3 countermovement jumps (CMJ) 3h30 prior to the start of the match. One hour following the match, subjective player performance ratings from the players and two members of the coaching staff were obtained. Naps were characterized into 3 conditions for analysis; No Nap (NN), <20 min Nap (SHORT), and ≥20 min Nap (LONG). A significant difference in peak jump velocity was observed between the SHORT and the NN condition in favor of the shorter nap (3.23 ± 0.26 and 3.07 ± 0.36 m.s -1 , respectively, d = 0.34, p < 0.05). A moderate, significant difference (d = 0.85; p < 0.05) was observed for the coach rating of performance (out of 10) between the SHORT and the NN condition (7.2 ± 0.8 and 6.4 ± 0.9, respectively) in favor of SHORT. The findings from the study would suggest that a short nap (<20 min) on the day of competition can enhance jump velocity and improve subjective performance in elite netball players, as assessed by coaching staff.

  9. Identification of Patients With Diabetes Who Benefit Most From a Health Coaching Program in Chronic Disease Management, Sydney, Australia, 2013.

    PubMed

    Delaney, Grace; Newlyn, Neroli; Pamplona, Elline; Hocking, Samantha L; Glastras, Sarah J; McGrath, Rachel T; Fulcher, Gregory R

    2017-03-02

    Chronic disease management programs (CDMPs) that include health coaching can facilitate and coordinate diabetes management. The aim of this study was to assess changes in patients' general knowledge of diabetes, self-reported health status, diabetes distress, body mass index (BMI), and glycemic control after enrollment in a face-to-face CDMP group health coaching session (with telephone follow-up) compared with participation in telephone-only health coaching, during a 12-month period. Patients with diabetes were enrolled in a health coaching program at Royal North Shore Hospital, Sydney, Australia, in 2013. Questionnaires were administered at baseline and at 3, 6, and 12 months, and the results were compared with baseline. Glycemic control, measured with glycated hemoglobin A 1c (HbA 1c ) and BMI, were measured at baseline and 12 months. Overall, 238 patients attended a face-to-face CDMP session with telephone follow-up (n = 178) or participated in telephone-only health coaching (n = 60). We found no change in BMI in either group; however, HbA 1c levels in patients with baseline above the current recommended target (>7%) decreased significantly from 8.5% (standard deviation [SD], 1.0%) to 7.9% (SD, 1.0%) (P = .03). Patients with the lowest self-reported health status at baseline improved from 4.4 (SD, 0.5) to 3.7 (SD, 0.9) (P = .001). Diabetes knowledge improved in all patients (24.4 [SD, 2.4] to 25.2 [SD, 2.4]; P < .001), and diabetes distress decreased among those with the highest levels of distress at baseline (3.0 [SD, 0.4] vs 3.8 [SD, 0.6]; P = .003). Diabetes health coaching programs can improve glycemic control and reduce diabetes distress in patients with high levels of these at baseline.

  10. SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, X; Yang, K; Liu, B

    Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length wasmore » used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.« less

  11. Effect of condensed tannins from Ficus infectoria and Psidium guajava leaf meal mixture on nutrient metabolism, methane emission and performance of lambs.

    PubMed

    Pathak, A K; Dutta, Narayan; Pattanaik, A K; Chaturvedi, V B; Sharma, K

    2017-12-01

    The study examined the effect of condensed tannins (CT) containing Ficus infectoria and Psidium guajava leaf meal mixture (LMM) supplementation on nutrient metabolism, methane emission and performance of lambs. Twenty four lambs of ~6 months age (average body weight 10.1±0.60 kg) were randomly divided into 4 dietary treatments (CT-0, CT-1, CT-1.5, and CT-2 containing 0, 1.0, 1.5, and 2.0 percent CT through LMM, respectively) consisting of 6 lambs each in a completely randomized design. All the lambs were offered a basal diet of wheat straw ad libitum, oat hay (100 g/d) along with required amount of concentrate mixture to meet their nutrient requirements for a period of 6 months. After 3 months of experimental feeding, a metabolism trial of 6 days duration was conducted on all 24 lambs to determine nutrient digestibility and nitrogen balance. Urinary excretion of purine derivatives and microbial protein synthesis were determined using high performance liquid chromatography. Respiration chamber study was started at the mid of 5th month of experimental feeding trial. Whole energy balance trials were conducted on individual lamb one after the other, in an open circuit respiration calorimeter. Intake of dry matter and organic matter (g/d) was significantly (p<0.05) higher in CT-1.5 than control. Digestibility of various nutrients did not differ irrespective of treatments. Nitrogen retention and microbial nitrogen synthesis (g/d) was significantly (p<0.01) higher in CT-1.5 and CT-2 groups relative to CT-0. Total body weight gain (kg) and average daily gain (g) were significantly (linear, p<0.01) higher in CT-1.5 followed by CT-1 and CT-0, respectively. Feed conversion ratio (FCR) by lambs was significantly (linear, p<0.01) better in CT-1.5 followed by CT-2 and CT-0, respectively. Total wool yield (g; g/d) was linearly (p<0.05) higher for CT-1.5 than CT-0. Methane emission was linearly decreased (p<0.05) in CT groups and reduction was highest (p<0.01) in CT-2 followed by CT-1.5 and CT-1. Methane energy (kcal/d) was linearly decreased (p<0.05) in CT groups. The CT supplementation at 1% to 2% of the diet through Ficus infectoria and Psidium guajava LMM significantly improved nitrogen metabolism, growth performance, wool yield, FCR and reduced methane emission by lambs.

  12. Effect of N-acetylcysteine on the early expression of inflammatory markers in the retina and plasma of diabetic rats

    PubMed Central

    Tsai, Gina Y; Cui, Jing Z; Syed, Husnain; Xia, Zhengyuan; Ozerdem, Ugur; McNeill, John H; Matsubara, Joanne A

    2014-01-01

    Purpose The aim of this study is to investigate markers of inflammation and oxidative stress in an early model of diabetic retinopathy, correlate retinal and plasma results and evaluate the influence of treatment by N-acetylcysteine (NAC), a free radical scavenger. Methods Four groups were studied: control (C), streptozotocin (STZ)-induced diabetic rats (D), STZ rats following 8 weeks of NAC (DT), and control rats following 8 weeks of NAC (CT). Plasma levels of free 15-F2t-isoprostane (15-F-2t-IsoP), superoxide dismutase (SOD) and tumour necrosis factor-alpha (TNF-α) were obtained. Primary antibodies against macrophages (ED-1), microglia (Ox-42), pericytes (NG-2), endothelial and perivascular cells (IB-4), haem oxygenase 1 (HO-1) and vascular endothelial growth factor (VEGF) were used. Results Expression of NG-2 was robust in C, CT, DT, and mild in D. The intensity of IB-4 was higher in D and DT compared with the C and CT. Ox-42 and ED-1 expression was higher in the D than in the DT, C or CT. Expression of VEGF and HO-1 was non-specific across the four groups. Plasma levels of 15-F-2t-IsoP and TNF-α were higher in the D as compared with the C, CT and DT. SOD levels were lower in the D when compared with the C, CT and D. Conclusions Macrophage/microglia activation, pericyte loss and endothelial/perivascular cell changes occur early in the pathogenesis of DR. These changes are associated with an increase in plasma markers of oxidative stress and inflammation and are minimized by treatment with NAC. The results suggest that therapies that reduce free radicals will help minimize the early events in diabetic retinopathy in the STZ model. PMID:19723131

  13. Health Coaching in Severe COPD After a Hospitalization: A Qualitative Analysis of a Large Randomized Study.

    PubMed

    Benzo, Roberto P; Kirsch, Janae L; Hathaway, Julie C; McEvoy, Charlene E; Vickers, Kristin S

    2017-11-01

    We recently demonstrated in a randomized study the feasibility and effectiveness of telephone-based health coaching using motivational interviewing on decreasing hospital readmissions and improving quality of life at 6 and 12 months after hospital discharge. In this qualitative study, we sought to explore the health-coaching intervention as seen from the perspective of the participants who received the intervention and the coaches who delivered it. Semistructured participant interviews ( n = 24) and a focus group of all health coaches ( n = 3) who participated in this study were conducted. Interviews and focus group were recorded and transcribed verbatim. Transcripts were analyzed using coding and categorizing techniques and thematic analysis. Mixed-method triangulation was used to merge quantitative and qualitative data. Content analysis revealed 4 predominant themes of the coaching intervention: health-coaching relationship, higher participant confidence and reassurance (most related to improvement in physical quality of life), improved health-care system access (most related to decreased hospital readmissions), and increased awareness of COPD symptoms (most related to improvement in emotional quality of life). The strongest theme was the relationship with the health coach, including coach style and motivational interviewing approach. Health coaches' focus group also noted the importance of the coaching relationship as the most significant theme. This study provided themes to further inform the delivery and implementation of health-coaching interventions in patients with COPD after hospital discharge. Health coaching forged partnerships and created a platform for patient engagement, which was confirmed by both participants and health coaches. Copyright © 2017 by Daedalus Enterprises.

  14. Physical activity levels during youth sport practice: does coach training or experience have an influence?

    PubMed

    Schlechter, Chelsey R; Rosenkranz, Richard R; Milliken, George A; Dzewaltowski, David A

    2017-01-01

    This study examined moderate-to-vigorous physical activity (MVPA) levels in youth during flag football practice and compared youth MVPA in practices led by trained or untrained, and by experienced or inexperienced, coaches. Boys (n = 111, mean age = 7.9 ± 1.2 years) from 14 recreation-level flag football teams wore an accelerometer during two practices. Each team's volunteer head coach reported prior training and coaching experience. Mixed-model team-adjusted means showed the proportion of practice time spent in sedentary (13 ± 1%), MVPA (34 ± 2%) and vigorous (12 ± 1%) activity. Practice contributed ~20 min of MVPA towards public health guidelines. There was no significant difference in percentage time spent in MVPA between teams with trained (mean = 33.3%, 95% CI = 29.4%, 37.2%) and untrained coaches (mean = 35.9%, 95% CI = 25.5%, 42.4%) or between experienced (mean = 34.1%, 95% CI = 30.2%, 38.0%) and inexperienced coaches (mean = 33.8, 95% CI = 27.9%, 39.7%). Although sport provides a setting for youth to accrue MVPA, two-thirds of practice was spent sedentarily or in light activity. Participation in a coach training programme was not associated with higher MVPA. Further research is needed to inform volunteer coach training programmes that provide coaches with skills necessary to increase the percentage of practice time spent in MVPA.

  15. Value of PET/CT 3D visualization of head and neck squamous cell carcinoma extended to mandible.

    PubMed

    Lopez, R; Gantet, P; Julian, A; Hitzel, A; Herbault-Barres, B; Alshehri, S; Payoux, P

    2018-05-01

    To study an original 3D visualization of head and neck squamous cell carcinoma extending to the mandible by using [18F]-NaF PET/CT and [18F]-FDG PET/CT imaging along with a new innovative FDG and NaF image analysis using dedicated software. The main interest of the 3D evaluation is to have a better visualization of bone extension in such cancers and that could also avoid unsatisfying surgical treatment later on. A prospective study was carried out from November 2016 to September 2017. Twenty patients with head and neck squamous cell carcinoma extending to the mandible (stage 4 in the UICC classification) underwent [18F]-NaF and [18F]-FDG PET/CT. We compared the delineation of 3D quantification obtained with [18F]-NaF and [18F]-FDG PET/CT. In order to carry out this comparison, a method of visualisation and quantification of PET images was developed. This new approach was based on a process of quantification of radioactive activity within the mandibular bone that objectively defined the significant limits of this activity on PET images and on a 3D visualization. Furthermore, the spatial limits obtained by analysis of the PET/CT 3D images were compared to those obtained by histopathological examination of mandibular resection which confirmed intraosseous extension to the mandible. The [18F]-NaF PET/CT imaging confirmed the mandibular extension in 85% of cases and was not shown in [18F]-FDG PET/CT imaging. The [18F]-NaF PET/CT was significantly more accurate than [18F]-FDG PET/CT in 3D assessment of intraosseous extension of head and neck squamous cell carcinoma. This new 3D information shows the importance in the imaging approach of cancers. All cases of mandibular extension suspected on [18F]-NaF PET/CT imaging were confirmed based on histopathological results as a reference. The [18F]-NaF PET/CT 3D visualization should be included in the pre-treatment workups of head and neck cancers. With the use of a dedicated software which enables objective delineation of radioactive activity within the bone, it gives a very encouraging results. The [18F]-FDG PET/CT appears insufficient to confirm mandibular extension. This new 3D simulation management is expected to avoid under treatment of patients with intraosseous mandibular extension of head and neck cancers. However, there is also a need for a further study that will compare the interest of PET/CT and PET/MRI in this indication. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  16. The Academy for Future Science Faculty: randomized controlled trial of theory-driven coaching to shape development and diversity of early-career scientists

    PubMed Central

    2014-01-01

    Background Approaches to training biomedical scientists have created a talented research community. However, they have failed to create a professional workforce that includes many racial and ethnic minorities and women in proportion to their representation in the population or in PhD training. This is particularly true at the faculty level. Explanations for the absence of diversity in faculty ranks can be found in social science theories that reveal processes by which individuals develop identities, experiences, and skills required to be seen as legitimate within the profession. Methods/Design Using the social science theories of Communities of Practice, Social Cognitive Career Theory, identity formation, and cultural capital, we have developed and are testing a novel coaching-based model to address some of the limitations of previous diversity approaches. This coaching intervention (The Academy for Future Science Faculty) includes annual in-person meetings of students and trained faculty Career Coaches, along with ongoing virtual coaching, group meetings and communication. The model is being tested as a randomized controlled trial with two cohorts of biomedical PhD students from across the U.S., one recruited at the start of their PhDs and one nearing completion. Stratification into the experimental and control groups, and to coaching groups within the experimental arms, achieved equal numbers of students by race, ethnicity and gender to the extent possible. A fundamental design element of the Academy is to teach and make visible the social science principles which highly influence scientific advancement, as well as acknowledging the extra challenges faced by underrepresented groups working to be seen as legitimate within the scientific communities. Discussion The strategy being tested is based upon a novel application of the well-established principles of deploying highly skilled coaches, selected and trained for their ability to develop talents of others. This coaching model is intended to be a complement, rather than a substitute, for traditional mentoring in biomedical research training, and is being tested as such. PMID:25084625

  17. CYP3A5*3 and ABCB1 61A>G Significantly Influence Dose-adjusted Trough Blood Tacrolimus Concentrations in the First Three Months Post-Kidney Transplantation.

    PubMed

    Hu, Rong; Barratt, Daniel T; Coller, Janet K; Sallustio, Benedetta C; Somogyi, Andrew A

    2018-03-30

    Tacrolimus (TAC) is a first-line immunosuppressant used to prevent organ rejection after kidney transplantation. There is large inter-individual variability in its pharmacokinetics. Single nucleotide polymorphisms (SNPs) in genes encoding TAC metabolizing enzymes cytochromes P450 3A4/5 (CYP3A4/5), P-glycoprotein efflux transporter (ABCB1), their expression regulator pregnane X receptor (NR1I2) and CYP3A co-factor cytochrome P450 reductase (POR) have been studied for their effects on tacrolimus disposition. However, except for CYP3A5*3, controversies remain about their roles in predicting dose-adjusted trough blood TAC concentrations (C 0 /D). This study aimed to investigate the effects of ABCB1 (61A>G, 1199G>A, 1236C>T, 2677G>T and 3435C>T), CYP3A4*22, CYP3A5*3, NR1I2 (8055C>T, 63396C>T and -25385C>T) and POR*28 SNPs on TAC C 0 /D. In total, 165 kidney transplant recipients were included in this study. SNPs were genotyped by probe-based real-time polymerase chain reaction. Associations between log-transformed whole blood TAC C 0 /D (measured at 1 and 3 months post-transplant) and genotypes/haplotypes were assessed by linear mixed effects analysis, controlling for age, sex and haematocrit. It was observed that CYP3A5 expressors (*1/*1 + *1/*3) (p = 5.5 × 10 -16 ) and ABCB1 61G allele carriers (p = 0.001) had lower log-transformed TAC C 0 /D (56% and 26% lower geometric mean TAC C 0 /D, respectively) and accounted for approximately 30% and 4%, respectively, of log-transformed TAC C 0 /D variability in the first 3 months post-transplant. In conclusion, CYP3A5*3 is a major, and ABCB1 61A>G is a novel, although minor, genetic factor affecting TAC C 0 /D in kidney transplant recipients. © 2018 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  18. SU-F-R-21: The Stability of Radiomics Features On 4D FDG-PET/CT Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, C

    2016-06-15

    Purpose: The aim of our study was to perform a stability analysis of 4D PET-derived features in non-small cell lung carcinoma (NSCLC) based on six different respiratory phases. Methods: The 4D FDG-PET/CT respiratory phases were labeled as T0%, T17%, T33%,T50%, T67%, T83% phases, with the T0% phase approximately corresponding to the normal end-inspiration. Lesions were manually delineated based on fused PET-CT, using a standardized clinical delineation protocol. Six texture parameters were analyzed. Results: Results showed that the majority of assessed features had a low stability such as Homogeneity (0.385–0.416), Dissimilarity (3.707–3.861), Angular two moments (0.013–0.019), Contrast (39.782–49.562), Entropy(4.683–5.002) and Inversemore » differential moment (0.317–0.362) on different respiratory phases. Conclusion: This study suggest that further research of quantitative PET imaging features is warranted with respect to respiratory motion.« less

  19. Low-energy charge transfer excitations in NiO

    NASA Astrophysics Data System (ADS)

    Sokolov, V. I.; Pustovarov, V. A.; Churmanov, V. N.; Ivanov, V. Yu; Yermakov, A. Ye; Uimin, M. A.; Gruzdev, N. B.; Sokolov, P. S.; Baranov, A. N.; Moskvin, A. S.

    2012-08-01

    Comparative analysis of photoluminescence (PL) and photoluminescence excitation (PLE) spectra of NiO poly- and nanocrystals in the spectral range 2-5.5 eV reveals two PLE bands peaked near 3.7 and 4.6 eV with a dramatic rise in the low-temperature PLE spectral weight of the 3.7 eV PLE band in the nanocrystalline NiO as compared with its polycrystalline counterpart. In frames of a cluster model approach we assign the 3.7 eV PLE band to the low-energy bulk-forbidden p-d (t1g(π)-eg) charge transfer (CT) transition which becomes the allowed one in the nanocrystalline state while the 4.6 eV PLE band is related to a bulk allowed d-d (eg-eg) CT transition scarcely susceptible to the nanocrystallization. The PLE spectroscopy of the nanocrystalline materials appears to be a novel informative technique for inspection of different CT transitions.

  20. MO-E-BRB-03: Panel Member

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salter, B.

    2016-06-15

    In this interactive session, lung SBRT patient cases will be presented to highlight real-world considerations for ensuring safe and accurate treatment delivery. An expert panel of speakers will discuss challenges specific to lung SBRT including patient selection, patient immobilization techniques, 4D CT simulation and respiratory motion management, target delineation for treatment planning, online treatment alignment, and established prescription regimens and OAR dose limits. Practical examples of cases, including the patient flow thought the clinical process are presented and audience participation will be encouraged. This panel session is designed to provide case demonstration and review for lung SBRT in terms ofmore » (1) clinical appropriateness in patient selection, (2) strategies for simulation, including 4D and respiratory motion management, and (3) applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent, and (4) image guidance in treatment delivery. Learning Objectives: Understand the established requirements for patient selection in lung SBRT Become familiar with the various immobilization strategies for lung SBRT, including technology for respiratory motion management Understand the benefits and pitfalls of applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent determination for lung SBRT Understand established prescription regimes and OAR dose limits.« less

  1. MO-E-BRB-01: Panel Member

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benedict, S.

    2016-06-15

    In this interactive session, lung SBRT patient cases will be presented to highlight real-world considerations for ensuring safe and accurate treatment delivery. An expert panel of speakers will discuss challenges specific to lung SBRT including patient selection, patient immobilization techniques, 4D CT simulation and respiratory motion management, target delineation for treatment planning, online treatment alignment, and established prescription regimens and OAR dose limits. Practical examples of cases, including the patient flow thought the clinical process are presented and audience participation will be encouraged. This panel session is designed to provide case demonstration and review for lung SBRT in terms ofmore » (1) clinical appropriateness in patient selection, (2) strategies for simulation, including 4D and respiratory motion management, and (3) applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent, and (4) image guidance in treatment delivery. Learning Objectives: Understand the established requirements for patient selection in lung SBRT Become familiar with the various immobilization strategies for lung SBRT, including technology for respiratory motion management Understand the benefits and pitfalls of applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent determination for lung SBRT Understand established prescription regimes and OAR dose limits.« less

  2. MO-E-BRB-00: PANEL DISCUSSION: SBRT/SRS Case Studies - Lung

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2016-06-15

    In this interactive session, lung SBRT patient cases will be presented to highlight real-world considerations for ensuring safe and accurate treatment delivery. An expert panel of speakers will discuss challenges specific to lung SBRT including patient selection, patient immobilization techniques, 4D CT simulation and respiratory motion management, target delineation for treatment planning, online treatment alignment, and established prescription regimens and OAR dose limits. Practical examples of cases, including the patient flow thought the clinical process are presented and audience participation will be encouraged. This panel session is designed to provide case demonstration and review for lung SBRT in terms ofmore » (1) clinical appropriateness in patient selection, (2) strategies for simulation, including 4D and respiratory motion management, and (3) applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent, and (4) image guidance in treatment delivery. Learning Objectives: Understand the established requirements for patient selection in lung SBRT Become familiar with the various immobilization strategies for lung SBRT, including technology for respiratory motion management Understand the benefits and pitfalls of applying multi imaging modality (4D CT imaging, MRI, PET) for tumor volume delineation and motion extent determination for lung SBRT Understand established prescription regimes and OAR dose limits.« less

  3. Highly Luminescent 2D-Type Slab Crystals Based on a Molecular Charge-Transfer Complex as Promising Organic Light-Emitting Transistor Materials.

    PubMed

    Park, Sang Kyu; Kim, Jin Hong; Ohto, Tatsuhiko; Yamada, Ryo; Jones, Andrew O F; Whang, Dong Ryeol; Cho, Illhun; Oh, Sangyoon; Hong, Seung Hwa; Kwon, Ji Eon; Kim, Jong H; Olivier, Yoann; Fischer, Roland; Resel, Roland; Gierschner, Johannes; Tada, Hirokazu; Park, Soo Young

    2017-09-01

    A new 2:1 donor (D):acceptor (A) mixed-stacked charge-transfer (CT) cocrystal comprising isometrically structured dicyanodistyrylbenzene-based D and A molecules is designed and synthesized. Uniform 2D-type morphology is manifested by the exquisite interplay of intermolecular interactions. In addition to its appealing structural features, unique optoelectronic properties are unveiled. Exceptionally high photoluminescence quantum yield (Φ F ≈ 60%) is realized by non-negligible oscillator strength of the S 1 transition, and rigidified 2D-type structure. Moreover, this luminescent 2D-type CT crystal exhibits balanced ambipolar transport (µ h and µ e of ≈10 -4 cm 2 V -1 s -1 ). As a consequence of such unique optoelectronic characteristics, the first CT electroluminescence is demonstrated in a single active-layered organic light-emitting transistor (OLET) device. The external quantum efficiency of this OLET is as high as 1.5% to suggest a promising potential of luminescent mixed-stacked CT cocrystals in OLET applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Tumor invasiveness defined by IASLC/ATS/ERS classification of ground-glass nodules can be predicted by quantitative CT parameters.

    PubMed

    Zhou, Qian-Jun; Zheng, Zhi-Chun; Zhu, Yong-Qiao; Lu, Pei-Ji; Huang, Jia; Ye, Jian-Ding; Zhang, Jie; Lu, Shun; Luo, Qing-Quan

    2017-05-01

    To investigate the potential value of CT parameters to differentiate ground-glass nodules between noninvasive adenocarcinoma and invasive pulmonary adenocarcinoma (IPA) as defined by IASLC/ATS/ERS classification. We retrospectively reviewed 211 patients with pathologically proved stage 0-IA lung adenocarcinoma which appeared as subsolid nodules, from January 2012 to January 2013 including 137 pure ground glass nodules (pGGNs) and 74 part-solid nodules (PSNs). Pathological data was classified under the 2011 IASLC/ATS/ERS classification. Both quantitative and qualitative CT parameters were used to determine the tumor invasiveness between noninvasive adenocarcinomas and IPAs. There were 154 noninvasive adenocarcinomas and 57 IPAs. In pGGNs, CT size and area, one-dimensional mean CT value and bubble lucency were significantly different between noninvasive adenocarcinomas and IPAs on univariate analysis. Multivariate regression and ROC analysis revealed that CT size and one-dimensional mean CT value were predictive of noninvasive adenocarcinomas compared to IPAs. Optimal cutoff value was 13.60 mm (sensitivity, 75.0%; specificity, 99.6%), and -583.60 HU (sensitivity, 68.8%; specificity, 66.9%). In PSNs, there were significant differences in CT size and area, solid component area, solid proportion, one-dimensional mean and maximum CT value, three-dimensional (3D) mean CT value between noninvasive adenocarcinomas and IPAs on univariate analysis. Multivariate and ROC analysis showed that CT size and 3D mean CT value were significantly differentiators. Optimal cutoff value was 19.64 mm (sensitivity, 53.7%; specificity, 93.9%), -571.63 HU (sensitivity, 85.4%; specificity, 75.8%). For pGGNs, CT size and one-dimensional mean CT value are determinants for tumor invasiveness. For PSNs, tumor invasiveness can be predicted by CT size and 3D mean CT value.

  5. Truck and Coach Mechanic. Apprenticeship Training Standards = Mecanicien de camions et d'autobus. Normes de formation en apprentissage.

    ERIC Educational Resources Information Center

    Ontario Ministry of Skills Development, Toronto.

    This manual presents training standards for truck and coach mechanics and is intended to be used by apprentice/trainees, instructors, and companies in Ontario, Canada, as a blueprint for training or as a prerequisite for accreditation/certification. The training standards identify skills required for this occupation and its related training…

  6. Case series of 64 slice computed tomography-computed tomographic angiography with 3D reconstruction to diagnose symptomatic cerebral aneurysms: new standard of care?

    PubMed Central

    Jehle, Dietrich; Chae, Floria; Wai, Jonathan; Cloud, Sam; Pierce, David; Meyer, Michael

    2012-01-01

    CT angiography (CTA) has improved significantly over the past few years such that the reconstructed images of the cerebral arteries may now be equivalent to conventional digital angiography. The new technology of 64 slice multi-detector CTA can reconstruct detailed images that can reliably identify small cerebral aneurysms, even those <3mm. In addition, it is estimated that CT followed by lumbar puncture (LP) misses up to 4% of symptomatic aneurysms. We present a series of cases that illustrates how CT followed by CTA may be replacing CT-LP as the standard of care in working up patients for symptomatic cerebral aneurysms and the importance of performing three dimensional (3D) reconstructions. A series of seven cases of symptomatic cerebral aneurysms were identified that illustrate the sensitivity of CT-CTA versus CT-LP and the importance of 3D reconstruction in identifying these aneurysms. Surgical treatment was recommended for 6 of the 7 patients with aneurysms and strict hypertension control was recommended for the seventh patient. Some of these patients demonstrated subarachnoid hemorrhage on presentation while others had negative LPs. A number of these patients with negative LPs were clearly symptomatic from their aneurysms. At least one of these cerebral aneurysms was not apparent on CTA without 3D reconstruction. 3D reconstruction of CTA is crucial to adequately identify cerebral aneurysms. This case series helps reinforce the importance of 3D reconstruction. There is some data to suggest that 64 slice CT-CTA may be equivalent or superior to CT-LP in the detection of symptomatic cerebral aneurysms. PMID:22593806

  7. Optical computed tomography for spatially isotropic four-dimensional imaging of live single cells

    PubMed Central

    Kelbauskas, Laimonas; Shetty, Rishabh; Cao, Bin; Wang, Kuo-Chen; Smith, Dean; Wang, Hong; Chao, Shi-Hui; Gangaraju, Sandhya; Ashcroft, Brian; Kritzer, Margaret; Glenn, Honor; Johnson, Roger H.; Meldrum, Deirdre R.

    2017-01-01

    Quantitative three-dimensional (3D) computed tomography (CT) imaging of living single cells enables orientation-independent morphometric analysis of the intricacies of cellular physiology. Since its invention, x-ray CT has become indispensable in the clinic for diagnostic and prognostic purposes due to its quantitative absorption-based imaging in true 3D that allows objects of interest to be viewed and measured from any orientation. However, x-ray CT has not been useful at the level of single cells because there is insufficient contrast to form an image. Recently, optical CT has been developed successfully for fixed cells, but this technology called Cell-CT is incompatible with live-cell imaging due to the use of stains, such as hematoxylin, that are not compatible with cell viability. We present a novel development of optical CT for quantitative, multispectral functional 4D (three spatial + one spectral dimension) imaging of living single cells. The method applied to immune system cells offers truly isotropic 3D spatial resolution and enables time-resolved imaging studies of cells suspended in aqueous medium. Using live-cell optical CT, we found a heterogeneous response to mitochondrial fission inhibition in mouse macrophages and differential basal remodeling of small (0.1 to 1 fl) and large (1 to 20 fl) nuclear and mitochondrial structures on a 20- to 30-s time scale in human myelogenous leukemia cells. Because of its robust 3D measurement capabilities, live-cell optical CT represents a powerful new tool in the biomedical research field. PMID:29226240

  8. Two- and three-dimensional CT measurements of urinary calculi length and width: a comparative study.

    PubMed

    Lidén, Mats; Thunberg, Per; Broxvall, Mathias; Geijer, Håkan

    2015-04-01

    The standard imaging procedure for a patient presenting with renal colic is unenhanced computed tomography (CT). The CT measured size has a close correlation to the estimated prognosis for spontaneous passage of a ureteral calculus. Size estimations of urinary calculi in CT images are still based on two-dimensional (2D) reformats. To develop and validate a calculus oriented three-dimensional (3D) method for measuring the length and width of urinary calculi and to compare the calculus oriented measurements of the length and width with corresponding 2D measurements obtained in axial and coronal reformats. Fifty unenhanced CT examinations demonstrating urinary calculi were included. A 3D symmetric segmentation algorithm was validated against reader size estimations. The calculus oriented size from the segmentation was then compared to the estimated size in axial and coronal 2D reformats. The validation showed 0.1 ± 0.7 mm agreement against reference measure. There was a 0.4 mm median bias for 3D estimated calculus length compared to 2D (P < 0.001), but no significant bias for 3D width compared to 2D. The length of a calculus in axial and coronal reformats becomes underestimated compared to 3D if its orientation is not aligned to the image planes. Future studies aiming to correlate calculus size with patient outcome should use a calculus oriented size estimation. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Heads Up: Concussion in High School Sports. Guide for Coaches

    ERIC Educational Resources Information Center

    Centers for Disease Control and Prevention, 2005

    2005-01-01

    This guide provides general information to high school sports coaches about concussions. It focuses on the fact that coaches can play a key role in preventing concussions and managing them properly when they occur. The following sections are included: (1) The Facts; (2) Signs and Symptoms; (3) Prevention and Preparation; (4) When a Concussion…

  10. Using a Learning Coach to Develop Family Medicine Residents' Goal-Setting and Reflection Skills

    PubMed Central

    George, Paul; Reis, Shmuel; Dobson, Margaret; Nothnagle, Melissa

    2013-01-01

    Background Self-directed learning (SDL) skills, such as self-reflection and goal setting, facilitate learning throughout a physician's career. Yet, residents do not often formally engage in these activities during residency. Intervention To develop resident SDL skills, we created a learning coach role for a junior faculty member to meet with second-year residents monthly to set learning goals and promote reflection. Methods The study was conducted from 2008–2010 at the Brown Family Medicine Residency in Pawtucket, Rhode Island. During individual monthly meetings with the learning coach, residents entered their learning goals and reflections into an electronic portfolio. A mixed-methods evaluation, including coach's ratings of goal setting and reflection, coach's meeting notes, portfolio entries, and resident interviews, was used to assess progress in residents' SDL abilities. Results Coach ratings of 25 residents' goal-setting ability increased from a mean of 1.9 to 4.6 (P < .001); ratings of reflective capacity increased from a mean of 2.0 to 4.7 (P < .001) during each year. Resident portfolio entries showed a range of domains for goal setting and reflection. Resident interviews demonstrated progressive independence in setting goals and appreciation of the value of reflection for personal development. Conclusions Introducing a learning coach, use of a portfolio, and providing protected time for self-reflected learning allowed residents to develop SDL skills at their own pace. The learning coach model may be applicable to other residency programs in developing resident lifelong learning skills. PMID:24404275

  11. Standardized 2D ultrasound versus 3D/4D ultrasound and image fusion for measurement of aortic aneurysm diameter in follow-up after EVAR.

    PubMed

    Pfister, Karin; Schierling, Wilma; Jung, Ernst Michael; Apfelbeck, Hanna; Hennersperger, Christoph; Kasprzak, Piotr M

    2016-01-01

    To compare standardised 2D ultrasound (US) to the novel ultrasonographic imaging techniques 3D/4D US and image fusion (combined real-time display of B mode and CT scan) for routine measurement of aortic diameter in follow-up after endovascular aortic aneurysm repair (EVAR). 300 measurements were performed on 20 patients after EVAR by one experienced sonographer (3rd degree of the German society of ultrasound (DEGUM)) with a high-end ultrasound machine and a convex probe (1-5 MHz). An internally standardized scanning protocol of the aortic aneurysm diameter in B mode used a so called leading-edge method. In summary, five different US methods (2D, 3D free-hand, magnetic field tracked 3D - Curefab™, 4D volume sweep, image fusion), each including contrast-enhanced ultrasound (CEUS), were used for measurement of the maximum aortic aneurysm diameter. Standardized 2D sonography was the defined reference standard for statistical analysis. CEUS was used for endoleak detection. Technical success was 100%. In augmented transverse imaging the mean aortic anteroposterior (AP) diameter was 4.0±1.3 cm for 2D US, 4.0±1.2 cm for 3D Curefab™, and 3.9±1.3 cm for 4D US and 4.0±1.2 for image fusion. The mean differences were below 1 mm (0.2-0.9 mm). Concerning estimation of aneurysm growth, agreement was found between 2D, 3D and 4D US in 19 of the 20 patients (95%). Definitive decision could always be made by image fusion. CEUS was combined with all methods and detected two out of the 20 patients (10%) with an endoleak type II. In one case, endoleak feeding arteries remained unclear with 2D CEUS but could be clearly localized by 3D CEUS and image fusion. Standardized 2D US allows adequate routine follow-up of maximum aortic aneurysm diameter after EVAR. Image Fusion enables a definitive statement about aneurysm growth without the need for new CT imaging by combining the postoperative CT scan with real-time B mode in a dual image display. 3D/4D CEUS and image fusion can improve endoleak characterization in selected cases but are not mandatory for routine practice.

  12. Effects of cholera toxin on the potential difference and motor responses induced by distension in the rat proximal small intestine in vivo.

    PubMed

    Kordasti, Shirin; Sapnara, Maria; Thomas, Evan A; Lindstrom, Erik; Forsman, Mikael; Bornstein, Joel C; Sjövall, Henrik

    2006-05-01

    Cholera toxin (CT) may induce uncontrolled firing in recurrent networks of secretomotor neurons in the submucous plexus. This hypothesis was tested in chloralose-anesthetized rats in vivo. The secretory reflex response to graded intestinal distension was measured with or without prior exposure to luminal CT. The transmural potential difference (PD) was used as a marker for electrogenic chloride secretion. In controls, distension increased PD, and this response was reduced by the neural blocker tetrodotoxin given serosally and the vasoactive intestinal peptide (VIP) receptor antagonist [4Cl-d-Phe(6),Leu(17)]VIP (2 mug.min(-1).kg(-1) iv) but unaffected by the serotonin 5-HT(3) receptor antagonist granisetron, by the nicotinic receptor antagonist hexamethonium, by the muscarinic receptor antagonist atropine, or by the cyclooxygenase inhibitor indomethacin. Basal PD increased significantly with time in CT-exposed segments, an effect blocked by granisetron, by indomethacin, and by [4Cl-d-Phe(6),Leu(17)]VIP but not by hexamethonium or atropine. In contrast, once the increased basal PD produced by CT was established, [4Cl-d-Phe(6),Leu(17)]VIP and indomethacin had no significant effect, whereas granisetron and hexamethonium markedly depressed basal PD. CT significantly reduced the increase in PD produced by distension, an effect reversed by granisetron, indomethacin, and atropine. CT also activated a specific motility response to distension, repeated cluster contractions, but only in animals pretreated with granisetron, indomethacin, or atropine. These data are compatible with the hypothesis that CT induces uncontrolled activity in submucous secretory networks. Development of this state depends on 5-HT(3) receptors, VIP receptors, and prostaglandin synthesis, whereas its maintenance depends on 5-HT(3) and nicotinic receptors but not VIP receptors. The motility effects of CT (probably reflecting myenteric activity) are partially suppressed via a mechanism involving 5-HT(3) and muscarinic receptors and prostaglandin synthesis.

  13. A Qualitative Study of How Health Coaches Support Patients in Making Health-Related Decisions and Behavioral Changes

    PubMed Central

    Thom, David H.; Wolf, Jessica; Gardner, Heather; DeVore, Denise; Lin, Michael; Ma, Andy; Ibarra-Castro, Ana; Saba, George

    2016-01-01

    PURPOSE Although health coaches are a growing resource for supporting patients in making health decisions, we know very little about the experience of health. We undertook a qualitative study of how health coaches support patients in making decisions and implementing changes to improve their health. METHODS We conducted 6 focus groups (3 in Spanish and 3 in English) with 25 patients and 5 friends or family members, followed by individual interviews with 42 patients, 17 family members, 17 health coaches, and 20 clinicians. Audio recordings were transcribed and analyzed by at least 2 members of the study team in ATLAS.ti using principles of grounded theory to identify themes and the relationship between them. RESULTS We identified 7 major themes that were related to each other in the final conceptual model. Similarities between health coaches and patients and the time health coaches spent with patients helped establish the health coach–patient relationship. The coach-patient relationship allowed for, and was further strengthened by, 4 themes of key coaching activities: education, personal support, practical support, and acting as a bridge between patients and clinicians. CONCLUSIONS We identified a conceptual model that supports the development of a strong relationship, which in turn provides the basis for effective coaching. These results can be used to design health coach training curricula and to support health coaches in practice. PMID:28376437

  14. Evaluation of Sports Nutrition Knowledge and Recommendations Among High School Coaches.

    PubMed

    Couture, Steven; Lamarche, Benoit; Morissette, Eliane; Provencher, Veronique; Valois, Pierre; Goulet, Claude; Drapeau, Vicky

    2015-08-01

    The objectives of this study were to evaluate high school coaches' knowledge in sports nutrition and the nutritional practices they recommend to their athletes. Forty-seven high school coaches in "leanness" and "non-leanness" sports from the greater region of Quebec (women = 44.7%) completed a questionnaire on nutritional knowledge and practices. "Leanness sports" were defined as sports where leanness or/and low bodyweight were considered important (e.g., cheerleading, swimming and gymnastics), and "non-leanness sports" were defined as sports where these factors are less important (e.g., football). Participants obtained a total mean score of 68.4% for the nutrition knowledge part of the questionnaire. More specifically, less than 30% of the coaches could answer correctly some general nutrition questions regarding carbohydrates and lipids. No significant difference in nutrition knowledge was observed between coaches from "leanness" and "non-leanness" sports or between men and women. Respondents with a university education scored higher than the others (73.3% vs. 63.3%, p < .05). Coaches who participated in coaching certification also obtained better results than those without a coaching certification. The most popular source of information about nutrition used by coaches was the Internet at 55%. The two most popular nutrition practices that coaches recommended to improve athlete performance were hydration and consumption of protein-rich foods. Recommendation for nutritional supplements use was extremely rare and was suggested only by football coaches, a nonleanness sport. Findings from this study indicate that coaches need sports nutrition education and specific training.

  15. Coaching to Enhance Quality of Implementation in Prevention.

    PubMed

    Dusenbury, Linda; Hansen, William B; Jackson-Newsom, Julia; Pittman, Donna; Wilson, Cicely; Simley, Kathleen; Ringwalt, Christopher; Pankratz, Melinda; Giles, Steven

    2010-01-01

    PURPOSE: This study describes topics covered by coaches assisting teachers implementing a research-based drug prevention program and explores how coaching affected student outcomes. DESIGN: The All Stars drug prevention curriculum was implemented by 16 urban teachers who received four coaching sessions. Two coaches participated. Coaches were interviewed by investigators to assess topics covered. Students completed pretest-posttest measures of mediators and substance use behaviors. FINDINGS: The average teacher was coached on 11.7 different topics, out of a total of 23 topics. Coaching topics most heavily emphasized included: introduction and wrap up; time management; general classroom management; teacher's movement around the class; asking open-ended questions; using students' questions, comments and examples to make desired points; general preparation; engaging high-risk youth; reading from the curriculum; implementing activities correctly; focusing on objectives and goals; maintaining a focus on the task; and improving depth of understanding. Seven coaching topics were found to relate to changes in student mediators and behavior. RESEARCH LIMITATIONS/IMPLICATIONS: The current study was exploratory. Future research should explore how teachers develop the particular skills required by prevention programs and how coaches can assist them. PRACTICAL IMPLICATIONS: We postulate five levels of skill development which coaches may address: (1) fundamental teaching skills, (2) mechanics of program delivery, (3) development of an interactive teaching style, (4) effective response to student input, and (5) effective tailoring and adaptation. ORIGINALITY/VALUE: This represents one of a very few studies that explores how coaching impacts outcomes in substance abuse prevention.

  16. Coaching to Enhance Quality of Implementation in Prevention

    PubMed Central

    Dusenbury, Linda; Hansen, William B.; Jackson-Newsom, Julia; Pittman, Donna; Wilson, Cicely; Simley, Kathleen; Ringwalt, Christopher; Pankratz, Melinda; Giles, Steven

    2010-01-01

    Purpose This study describes topics covered by coaches assisting teachers implementing a research-based drug prevention program and explores how coaching affected student outcomes. Design The All Stars drug prevention curriculum was implemented by 16 urban teachers who received four coaching sessions. Two coaches participated. Coaches were interviewed by investigators to assess topics covered. Students completed pretest-posttest measures of mediators and substance use behaviors. Findings The average teacher was coached on 11.7 different topics, out of a total of 23 topics. Coaching topics most heavily emphasized included: introduction and wrap up; time management; general classroom management; teacher's movement around the class; asking open-ended questions; using students' questions, comments and examples to make desired points; general preparation; engaging high-risk youth; reading from the curriculum; implementing activities correctly; focusing on objectives and goals; maintaining a focus on the task; and improving depth of understanding. Seven coaching topics were found to relate to changes in student mediators and behavior. Research Limitations/Implications The current study was exploratory. Future research should explore how teachers develop the particular skills required by prevention programs and how coaches can assist them. Practical Implications We postulate five levels of skill development which coaches may address: (1) fundamental teaching skills, (2) mechanics of program delivery, (3) development of an interactive teaching style, (4) effective response to student input, and (5) effective tailoring and adaptation. Originality/Value This represents one of a very few studies that explores how coaching impacts outcomes in substance abuse prevention. PMID:22022672

  17. Registration of 4D cardiac CT sequences under trajectory constraints with multichannel diffeomorphic demons.

    PubMed

    Peyrat, Jean-Marc; Delingette, Hervé; Sermesant, Maxime; Xu, Chenyang; Ayache, Nicholas

    2010-07-01

    We propose a framework for the nonlinear spatiotemporal registration of 4D time-series of images based on the Diffeomorphic Demons (DD) algorithm. In this framework, the 4D spatiotemporal registration is decoupled into a 4D temporal registration, defined as mapping physiological states, and a 4D spatial registration, defined as mapping trajectories of physical points. Our contribution focuses more specifically on the 4D spatial registration that should be consistent over time as opposed to 3D registration that solely aims at mapping homologous points at a given time-point. First, we estimate in each sequence the motion displacement field, which is a dense representation of the point trajectories we want to register. Then, we perform simultaneously 3D registrations of corresponding time-points with the constraints to map the same physical points over time called the trajectory constraints. Under these constraints, we show that the 4D spatial registration can be formulated as a multichannel registration of 3D images. To solve it, we propose a novel version of the Diffeomorphic Demons (DD) algorithm extended to vector-valued 3D images, the Multichannel Diffeomorphic Demons (MDD). For evaluation, this framework is applied to the registration of 4D cardiac computed tomography (CT) sequences and compared to other standard methods with real patient data and synthetic data simulated from a physiologically realistic electromechanical cardiac model. Results show that the trajectory constraints act as a temporal regularization consistent with motion whereas the multichannel registration acts as a spatial regularization. Finally, using these trajectory constraints with multichannel registration yields the best compromise between registration accuracy, temporal and spatial smoothness, and computation times. A prospective example of application is also presented with the spatiotemporal registration of 4D cardiac CT sequences of the same patient before and after radiofrequency ablation (RFA) in case of atrial fibrillation (AF). The intersequence spatial transformations over a cardiac cycle allow to analyze and quantify the regression of left ventricular hypertrophy and its impact on the cardiac function.

  18. The Feasibility, Acceptability, and Outcomes of PRIME-D: A Novel Mobile Intervention Treatment for Depression

    PubMed Central

    Schlosser, Danielle A.; Campellone, Timothy R.; Truong, Brandy; Anguera, Joaquin A.; Vergani, Silvia; Vinogradov, Sophia; Arean, Patricia

    2017-01-01

    Background Despite decades of research and development, depression has risen from the 5th to the leading cause of disability in the U.S. Barriers to progress in the field are 1) Poor access to high quality care; 2) Limited mental health workforce; and 3) Few providers trained in the delivery of evidence-based treatments (EBTs). While mobile platforms are being developed to give consumers greater access to high quality care, too often these tools do not have empirical support for their effectiveness. In this study, we evaluated PRIME-D, a mobile app intervention that uses social networking, goal setting, and a mental health coach to deliver text-based, EBT’s to treat mood symptoms and functioning in adults with depression. Methods Thirty-six adults with depression remotely participated in PRIME-D over an 8-week period with a 4-week follow up, with 83% retained over the 12-week course of the study. Results On average, participants logged into the app 5 days/week. Depression scores (PHQ-9) significantly improved over time (over 50% reduction), with coach interactions enhancing these effects. Mood-related disability (SDS) also significantly decreased over time with participants no longer being impaired by their mood symptoms. Overall use of PRIME-D predicted greater gains in functioning. Improvements in mood and functioning were sustained over the 4-week follow-up. Conclusions Results suggest that PRIME-D is a feasible, acceptable, and effective intervention for adults with depression and that a mobile service delivery model may address the serious public health problem of poor access to high quality mental health care. PMID:28419621

  19. 52. EQUIPMENT HOUSE, Y&D No. 107730 Scales 1/4', 3/8', 3/4', ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    52. EQUIPMENT HOUSE, Y&D No. 107730 Scales 1/4', 3/8', 3/4', 1-1/2' and 3' = 1'; July 2, 1929 - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  20. Acquiring 4D Thoracic CT Scans Using Ciné CT Acquisition

    NASA Astrophysics Data System (ADS)

    Low, Daniel

    One method for acquiring 4D thoracic CT scans is to use ciné acquisition. Ciné acquisition is conducted by rotating the gantry and acquiring x-ray projections while keeping the couch stationary. After a complete rotation, a single set of CT slices, the number corresponding to the number of CT detector rows, is produced. The rotation period is typically sub second so each image set corresponds to a single point in time. The ciné image acquisition is repeated for at least one breathing cycle to acquire images throughout the breathing cycle. Once the images are acquired at a single couch position, the couch is moved to the abutting position and the acquisition is repeated. Post-processing of the images sets typically resorts the sets into breathing phases, stacking images from a specific phase to produce a thoracic CT scan at that phase. Benefits of the ciné acquisition protocol include, the ability to precisely identify the phase with respect to the acquired image, the ability to resort images after reconstruction, and the ability to acquire images over arbitrarily long times and for arbitrarily many images (within dose constraints).

  1. TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balasubramoniam, A; Bednarek, D; Rudin, S

    Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametricmore » maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.« less

  2. Effect of different breathing patterns in the same patient on stereotactic ablative body radiotherapy dosimetry for primary renal cell carcinoma: A case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pham, Daniel, E-mail: Daniel.Pham@petermac.org; Kron, Tomas; Foroudi, Farshad

    2013-10-01

    Stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) targets requires motion management strategies to verify dose delivery. This case study highlights the effect of a change in patient breathing amplitude on the dosimetry to organs at risk and target structures. A 73-year-old male patient was planned for receiving 26 Gy of radiation in 1 fraction of SABR for a left primary RCC. The patient was simulated with four-dimensional computed tomography (4DCT) and the tumor internal target volume (ITV) was delineated using the 4DCT maximum intensity projection. However, the initially planned treatment was abandoned at the radiation oncologist'smore » discretion after pretreatment cone-beam CT (CBCT) motion verification identified a greater than 50% reduction in superior to inferior diaphragm motion as compared with the planning 4DCT. This patient was resimulated with respiratory coaching instructions. To assess the effect of the change in breathing on the dosimetry to the target, each plan was recalculated on the data set representing the change in breathing condition. A change from smaller to larger breathing showed a 46% loss in planning target volume (PTV) coverage, whereas a change from larger breathing to smaller breathing resulted in an 8% decrease in PTV coverage. ITV coverage was similarly reduced by 8% in both scenarios. This case study highlights the importance of tools to verify breathing motion prior to treatment delivery. 4D image guided radiation therapy verification strategies should focus on not only verifying ITV margin coverage but also the effect on the surrounding organs at risk.« less

  3. Evaluation of the Diagnostic Accuracy of Conventional 2-Dimensional and 3-Dimensional Computed Tomography for Assessing Canine Sacral and Pelvic Fractures by Radiologists, Orthopedic Surgeons, and Veterinary Medical Students.

    PubMed

    Stieger-Vanegas, Susanne M; Senthirajah, Sri Kumar Jamie; Nemanic, Sarah; Baltzer, Wendy; Warnock, Jennifer; Hollars, Katelyn; Lee, Scott S; Bobe, Gerd

    2015-08-01

    To determine, using 3 groups of evaluators of varying experience reading orthopedic CT studies, if 3-dimensional computed tomography (3D-CT) provides a more accurate and time efficient method for diagnosis of canine sacral and pelvic fractures, and displacements of the sacroiliac and coxofemoral joints compared with 2-dimensional computed tomography (2D-CT). Retrospective clinical and prospective study. Dogs (n = 23): 12 dogs with traumatic pelvic fractures, 11 canine cadavers with pelvic trauma induced by a lateral impactor. All dogs had a 2D-CT exam of the pelvis and subsequent 3D-CT reconstructions from the 2D-CT images. Both 2D-CT and 3D-CT studies were anonymized and randomly presented to 2 veterinary radiologists, 2 veterinary orthopedic surgeons, and 2 veterinary medical students. Evaluators classified fractures using a confidence scale and recorded the duration of evaluation for each modality and case. 3D-CT was a more time-efficient technique for evaluation of traumatic sacral and pelvic injuries compared with 2D-CT in all evaluator groups irrespective of experience level reading orthopedic CT studies. However, for radiologists and surgeons, 2D-CT was the more accurate technique for evaluating sacral and pelvic fractures. 3D-CT improves sacral and pelvic fracture diagnosis when added to 2D-CT; however, 3D-CT has a reduced accuracy for evaluation of sacral and pelvic fractures if used without concurrent evaluation of 2D-CT images. © Copyright 2014 by The American College of Veterinary Surgeons.

  4. Triplet and ground state potential energy surfaces of 1,4-diphenyl-1,3-butadiene: theory and experiment.

    PubMed

    Saltiel, J; Dmitrenko, O; Pillai, Z S; Klima, R; Wang, S; Wharton, T; Huang, Z-N; van de Burgt, L J; Arranz, J

    2008-05-01

    Relative energies of the ground state isomers of 1,4-diphenyl-1,3-butadiene (DPB) are determined from the temperature dependence of equilibrium isomer compositions obtained with the use of diphenyl diselenide as catalyst. Temperature and concentration effects on photostationary states and isomerization quantum yields with biacetyl or fluorenone as triplet sensitizers with or without the presence of O(2), lead to significant modification of the proposed DPB triplet potential energy surface. Quantum yields for ct-DPB formation from tt-DPB increase with [tt-DPB] revealing a quantum chain process in the tt --> ct direction, as had been observed for the ct --> tt direction, and suggesting an energy minimum at the (3)ct* geometry. They confirm the presence of planar and twisted isomeric triplets in equilibrium (K), with energy transfer from planar or quasi-planar geometries (quantum chain events from tt and ct triplets) and unimolecular decay (k(d)) from twisted geometries. Starting from cc-DPB, varphi(cc-->tt) increases with increasing [cc-DPB] whereas varphi(cc-->ct) is relatively insensitive to concentration changes. The concentration and temperature dependencies of the decay rate constants of DPB triplets in cyclohexane are consistent with the mechanism deduced from the photoisomerization quantum yields. The experimental DeltaH between (3)tt-DPB* and (3)tp-DPB*, 2.7 kcal mol(-1), is compared with the calculated energy difference [DFT with B3LYP/6-31+G(d,p) basis set]. Use of the calculated DeltaS = 4.04 eu between the two triplets gives k(d) = (2.4-6.4) x 10(7) s(-1), close to 1.70 x 10(7) s(-1), the value for twisted stilbene triplet decay. Experimental and calculated relative energies of DPB isomers on the ground and triplet state surfaces agree and theory is relied upon to deduce structural characteristics of the equilibrated conformers in the DPB triplet state.

  5. Smartphone-Enabled Health Coaching Intervention (iMOVE) to Promote Long-Term Maintenance of Physical Activity in Breast Cancer Survivors: Protocol for a Feasibility Pilot Randomized Controlled Trial

    PubMed Central

    Ritvo, Paul; Obadia, Maya; Santa Mina, Daniel; Alibhai, Shabbir; Sabiston, Catherine; Oh, Paul; Campbell, Kristin; McCready, David; Auger, Leslie

    2017-01-01

    Background Although physical activity has been shown to contribute to long-term disease control and health in breast cancer survivors, a majority of breast cancer survivors do not meet physical activity guidelines. Past research has focused on promoting physical activity components for short-term breast cancer survivor benefits, but insufficient attention has been devoted to long-term outcomes and sustained exercise adherence. We are assessing a health coach intervention (iMOVE) that uses mobile technology to increase and sustain physical activity maintenance in initially inactive breast cancer survivors. Objective This pilot randomized controlled trial (RCT) is an initial step in evaluating the iMOVE intervention and will inform development of a full-scale pragmatic RCT. Methods We will enroll 107 physically inactive breast cancer survivors and randomly assign them to intervention or control groups at the University Health Network, a tertiary cancer care center in Toronto, Canada. Participants will be women (age 18 to 74 years) stratified by age (55 years and older/younger than 55 years) and adjuvant hormone therapy (AHT) exposure (AHT vs no AHT) following breast cancer treatment with no metastases or recurrence who report less than 60 minutes of preplanned physical activity per week. Both intervention and control groups receive the 12-week physical activity program with weekly group sessions and an individualized, progressive, home-based exercise program. The intervention group will additionally receive (1) 10 telephone-based health coaching sessions, (2) smartphone with data plan, if needed, (3) supportive health tracking software (Connected Wellness, NexJ Health Inc), and (4) a wearable step-counting device linked to a smartphone program. Results We will be assessing recruitment rates; acceptability reflected in selective, semistructured interviews; and enrollment, retention, and adherence quantitative intervention markers as pilot outcome measures. The primary clinical outcome will be directly measured peak oxygen consumption. Secondary clinical outcomes include health-related quality of life and anthropometric measures. All outcome measures are administered at baseline, after exercise program (month 3), and 6 months after program (month 9). Conclusions This pilot RCT will inform full-scale RCT planning. We will assess pilot procedures and interventions and collect preliminary effect estimates. Trial Registration ClinicalTrials.gov NCT02620735; https://clinicaltrials.gov/ct2/show/NCT02620735 (Archived by WebCite at https://clinicaltrials.gov/ct2/show/NCT02620735) PMID:28838886

  6. Smartphone-Enabled Health Coaching Intervention (iMOVE) to Promote Long-Term Maintenance of Physical Activity in Breast Cancer Survivors: Protocol for a Feasibility Pilot Randomized Controlled Trial.

    PubMed

    Ritvo, Paul; Obadia, Maya; Santa Mina, Daniel; Alibhai, Shabbir; Sabiston, Catherine; Oh, Paul; Campbell, Kristin; McCready, David; Auger, Leslie; Jones, Jennifer Michelle

    2017-08-24

    Although physical activity has been shown to contribute to long-term disease control and health in breast cancer survivors, a majority of breast cancer survivors do not meet physical activity guidelines. Past research has focused on promoting physical activity components for short-term breast cancer survivor benefits, but insufficient attention has been devoted to long-term outcomes and sustained exercise adherence. We are assessing a health coach intervention (iMOVE) that uses mobile technology to increase and sustain physical activity maintenance in initially inactive breast cancer survivors. This pilot randomized controlled trial (RCT) is an initial step in evaluating the iMOVE intervention and will inform development of a full-scale pragmatic RCT. We will enroll 107 physically inactive breast cancer survivors and randomly assign them to intervention or control groups at the University Health Network, a tertiary cancer care center in Toronto, Canada. Participants will be women (age 18 to 74 years) stratified by age (55 years and older/younger than 55 years) and adjuvant hormone therapy (AHT) exposure (AHT vs no AHT) following breast cancer treatment with no metastases or recurrence who report less than 60 minutes of preplanned physical activity per week. Both intervention and control groups receive the 12-week physical activity program with weekly group sessions and an individualized, progressive, home-based exercise program. The intervention group will additionally receive (1) 10 telephone-based health coaching sessions, (2) smartphone with data plan, if needed, (3) supportive health tracking software (Connected Wellness, NexJ Health Inc), and (4) a wearable step-counting device linked to a smartphone program. We will be assessing recruitment rates; acceptability reflected in selective, semistructured interviews; and enrollment, retention, and adherence quantitative intervention markers as pilot outcome measures. The primary clinical outcome will be directly measured peak oxygen consumption. Secondary clinical outcomes include health-related quality of life and anthropometric measures. All outcome measures are administered at baseline, after exercise program (month 3), and 6 months after program (month 9). This pilot RCT will inform full-scale RCT planning. We will assess pilot procedures and interventions and collect preliminary effect estimates. ClinicalTrials.gov NCT02620735; https://clinicaltrials.gov/ct2/show/NCT02620735 (Archived by WebCite at https://clinicaltrials.gov/ct2/show/NCT02620735). ©Paul Ritvo, Maya Obadia, Daniel Santa Mina, Shabbir Alibhai, Catherine Sabiston, Paul Oh, Kristin Campbell, David McCready, Leslie Auger, Jennifer Michelle Jones. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 24.08.2017.

  7. Registration of multiple video images to preoperative CT for image-guided surgery

    NASA Astrophysics Data System (ADS)

    Clarkson, Matthew J.; Rueckert, Daniel; Hill, Derek L.; Hawkes, David J.

    1999-05-01

    In this paper we propose a method which uses multiple video images to establish the pose of a CT volume with respect to video camera coordinates for use in image guided surgery. The majority of neurosurgical procedures require the neurosurgeon to relate the pre-operative MR/CT data to the intra-operative scene. Registration of 2D video images to the pre-operative 3D image enables a perspective projection of the pre-operative data to be overlaid onto the video image. Our registration method is based on image intensity and uses a simple iterative optimization scheme to maximize the mutual information between a video image and a rendering from the pre-operative data. Video images are obtained from a stereo operating microscope, with a field of view of approximately 110 X 80 mm. We have extended an existing information theoretical framework for 2D-3D registration, so that multiple video images can be registered simultaneously to the pre-operative data. Experiments were performed on video and CT images of a skull phantom. We took three video images, and our algorithm registered these individually to the 3D image. The mean projection error varied between 4.33 and 9.81 millimeters (mm), and the mean 3D error varied between 4.47 and 11.92 mm. Using our novel techniques we then registered five video views simultaneously to the 3D model. This produced an accurate and robust registration with a mean projection error of 0.68 mm and a mean 3D error of 1.05 mm.

  8. A randomized controlled trial of directive and nondirective smoking cessation coaching through an employee quitline.

    PubMed

    Sumner, Walton; Walker, Mark S; Highstein, Gabrielle R; Fischer, Irene; Yan, Yan; McQueen, Amy; Fisher, Edwin B

    2016-07-11

    Telephone quitlines can help employees quit smoking. Quitlines typically use directive coaching, but nondirective, flexible coaching is an alternative. Call-2-Quit used a worksite-sponsored quitline to compare directive and nondirective coaching modes, and evaluated employee race and income as potential moderators. An unblinded randomized controlled trial compared directive and nondirective telephone coaching by trained laypersons. Participants were smoking employees and spouses recruited through workplace smoking cessation campaigns in a hospital system and affiliated medical school. Coaches were four non-medical women trained to use both coaching modes. Participants were randomized by family to coaching mode. Participants received up to 7 calls from coaches who used computer assisted telephone interview software to track topics and time. Outcomes were reported smoking abstinence for 7 days at last contact, 6 or 12 months after coaching began. Both worksites implemented new tobacco control policies during the study. Most participants responded to an insurance incentive introduced at the hospital. Call-2-Quit coached 518 participants: 22 % were African-American; 45 % had incomes below $30,000. Income, race, and intervention did not affect coaching completion rates. Cessation rates were comparable with directive and nondirective coaching (26 % versus 30 % quit, NS). A full factorial logistic regression model identified above median income (odds ratio = 1.8, p = 0.02), especially among African Americans (p = 0.04), and recent quit attempts (OR = 1.6, p = 0.03) as predictors of cessation. Nondirective coaching was associated with high cessation rates among subgroups of smokers reporting income above the median, recent quit attempts, or use of alternative therapies. Waiting up to 4 weeks to start coaching did not affect cessation. Of 41 highly addicted or depressed smokers who had never quit more than 30 days, none quit. Nondirective coaching improved cessation rates for selected smoking employees, but less expensive directive coaching helped most smokers equally well, regardless of enrollment incentives and delays in receiving coaching. Some subgroups had very low cessation rates with either mode of quitline support. ClinicalTrials.gov NCT02730260 , Registered March 31, 2016.

  9. Evaluation of three-dimensional computed tomography processing for deep inferior epigastric perforator flap breast reconstruction.

    PubMed

    Teoh, Raymond; Johnson, Raleigh F; Nishino, Thomas K; Ethridge, Richard T

    2007-01-01

    The deep inferior epigastric perforator flap procedure has become a popular alternative for women who require breast reconstruction. One of the difficulties with this procedure is identifying perforator arteries large enough to ensure that the harvested tissue is well vascularized. Current techniques involve imaging the perforator arteries with computed tomography (CT) to produce a grid mapping the locations of the perforator arteries relative to the umbilicus. To compare the time it takes to produce a map of the perforators using either two-dimensional (2D) or three-dimensional (3D) CT, and to see whether there is a benefit in using a 3D model. Patient CT abdomen and pelvis scans were acquired from a GE 64-slice scanner. CT image processing was performed with the GE 3D Advantage Workstation v4.2 software. Maps of the perforators were generated both as 2D and 3D representations. Perforators within a region 5 cm rostral and 7 cm caudal to the umbilicus were measured and the times to perform these measurements using both 2D and 3D images were recorded by a stopwatch. Although the 3D method took longer than the 2D method (mean [+/- SD] time 1:51+/-0:35 min versus 1:08+/-0:16 min per perforator artery, respectively), producing a 3D image provides much more information than the 2D images alone. Additionally, an actual-sized 3D image can be printed out, removing the need to make measurements and producing a grid. Although it took less time to create a grid of the perforators using 2D axial CT scans, the 3D reconstruction of the abdomen allows the plastic surgeons to better visualize the patient's anatomy and has definite clinical utility.

  10. Impact of 4D image quality on the accuracy of target definition.

    PubMed

    Nielsen, Tine Bjørn; Hansen, Christian Rønn; Westberg, Jonas; Hansen, Olfred; Brink, Carsten

    2016-03-01

    Delineation accuracy of target shape and position depends on the image quality. This study investigates whether the image quality on standard 4D systems has an influence comparable to the overall delineation uncertainty. A moving lung target was imaged using a dynamic thorax phantom on three different 4D computed tomography (CT) systems and a 4D cone beam CT (CBCT) system using pre-defined clinical scanning protocols. Peak-to-peak motion and target volume were registered using rigid registration and automatic delineation, respectively. A spatial distribution of the imaging uncertainty was calculated as the distance deviation between the imaged target and the true target shape. The measured motions were smaller than actual motions. There were volume differences of the imaged target between respiration phases. Imaging uncertainties of >0.4 cm were measured in the motion direction which showed that there was a large distortion of the imaged target shape. Imaging uncertainties of standard 4D systems are of similar size as typical GTV-CTV expansions (0.5-1 cm) and contribute considerably to the target definition uncertainty. Optimising and validating 4D systems is recommended in order to obtain the most optimal imaged target shape.

  11. Evaluation of Antivascular Combretastatin A4 P Efficacy Using Supersonic Shear Imaging Technique of Ectopic Colon Carcinoma CT26.

    PubMed

    Seguin, Johanne; Mignet, Nathalie; Latorre Ossa, Heldmuth; Tanter, Mickaël; Gennisson, Jean-Luc

    2017-10-01

    A recent ultrasound imaging technique-shear wave elastography-showed its ability to image and quantify the mechanical properties of biological tissues, such as prostate or liver tissues. In the present study this technique was used to evaluate the relationship among tumor growth, stiffness and reduction of treatment with combretastatin (CA4 P) in allografted colon tumor CT26 in mice. During 12 d, CT26 tumor growth (n = 52) was imaged by ultrasound, and shear modulus was quantified, showing a good correlation between tumor volume and stiffness (r = 0.59). The treatment was initiated at d 12 and monitored every d during 4 d. Following the treatment, the tumor volume had decreased, while the elasticity of the tumor volume remained steady throughout the treatment. After segmentation using the shear modulus map, a detailed analysis showed a decrease in the stiffness after treatment. This reduction in the mechanical properties was shown to correlate with tissue reorganization, particularly, fibrosis and necrosis, assessed by histology. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siversson, Carl, E-mail: carl.siversson@med.lu.se; Nordström, Fredrik; Department of Radiation Physics, Skåne University Hospital, Lund 214 28

    2015-10-15

    Purpose: In order to enable a magnetic resonance imaging (MRI) only workflow in radiotherapy treatment planning, methods are required for generating Hounsfield unit (HU) maps (i.e., synthetic computed tomography, sCT) for dose calculations, directly from MRI. The Statistical Decomposition Algorithm (SDA) is a method for automatically generating sCT images from a single MR image volume, based on automatic tissue classification in combination with a model trained using a multimodal template material. This study compares dose calculations between sCT generated by the SDA and conventional CT in the male pelvic region. Methods: The study comprised ten prostate cancer patients, for whommore » a 3D T2 weighted MRI and a conventional planning CT were acquired. For each patient, sCT images were generated from the acquired MRI using the SDA. In order to decouple the effect of variations in patient geometry between imaging modalities from the effect of uncertainties in the SDA, the conventional CT was nonrigidly registered to the MRI to assure that their geometries were well aligned. For each patient, a volumetric modulated arc therapy plan was created for the registered CT (rCT) and recalculated for both the sCT and the conventional CT. The results were evaluated using several methods, including mean average error (MAE), a set of dose-volume histogram parameters, and a restrictive gamma criterion (2% local dose/1 mm). Results: The MAE within the body contour was 36.5 ± 4.1 (1 s.d.) HU between sCT and rCT. Average mean absorbed dose difference to target was 0.0% ± 0.2% (1 s.d.) between sCT and rCT, whereas it was −0.3% ± 0.3% (1 s.d.) between CT and rCT. The average gamma pass rate was 99.9% for sCT vs rCT, whereas it was 90.3% for CT vs rCT. Conclusions: The SDA enables a highly accurate MRI only workflow in prostate radiotherapy planning. The dosimetric uncertainties originating from the SDA appear negligible and are notably lower than the uncertainties introduced by variations in patient geometry between imaging sessions.« less

  13. The Operational Equations of State, 4: The Dulong-Petit Equation of State for Hydrocode

    DTIC Science & Technology

    2012-07-01

    1 1 , 2 2 ln T T T T V S S V S V S HHC C H V V E S V C C E E P VdE E E V d e CT e d V CT...71. 9. Grinfeld, M. A. Thermodynamic Methods in the Theory of Heterogeneous Systems , Longman, New York, 1991. NO. OF COPIES ORGANIZATION

  14. SU-F-J-162: Is Bulky Electron Density Assignment Appropriatefor MRI-Only Based Treatment Planning for Lung Cancer?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prior, P; Chen, X; Johnstone, C

    Purpose: To assess the appropriateness of bulky electron density assisment for MRI-only treatment planning for lung cancer via comparing dosimetric difference between MRI- and CT-based plans. Methods: Planning 4DCTs acquired for six representative lung cancer patients were used to generate CT-based IMRT plans. To avoid the effect of anatomic difference between CT and MRI, MRI-based plans were generated using CTs by forcing the relative electron density (rED) of organ specific values from ICRU report 46 and using the mean rED value of the internal target volume (ITV) of the patient for the ITV. Both CT and “MRI” plans were generatedmore » using a research planning system (Monaco, Elekta) employing Monte Carlo dose calculation the following dose-volume-parameters (DVPs): D99 – dose delivered to 99% of the ITV/PTV volume; D95; D5; D1; Vpd –volume receiving the prescription dose; V5 – volume of normal lung irradiated > 5 Gy; and V20. The percent point difference and dose difference was used for comparison for Vpd-V5-V20 and D99-D1, respectively. Four additional plans per patient were calculated with rEDITV = 0.6 and 1.0 and rEDlung = 0.1 and 0.5. Results: Noticeable differences in the ITV and PTV point doses and DVPs were observed. Variations in Vpd ranged from 0.0–6.4% and 0.32–18.3% for the ITV and PTV, respectively. The ITV and PTV variations in D99, D95, D5 and D1 were 0.15–3.2 Gy. The normal lung V5 & V20 variations were no larger than 1.9%. In some instances, varying the rEDITV between rEDmean, 0.6 and 1.0 resulted in D95 increases ranging from 3.9–6.3%. Uniform rED assignment on normal lung affected DVPs of ITV and PTV by 4.0–9.8% and 0.3–19.6%, respectively. Conclusion: The commonly-used uniform rED assignment in MRI-only based planning may not be appropriate for lung-cancer. A voxel based method, e.g. synthetic CT generated from MRI data, is required. This work was partially funded by Elekta, Inc.« less

  15. Three-dimensional texture analysis of contrast enhanced CT images for treatment response assessment in Hodgkin lymphoma: Comparison with F-18-FDG PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knogler, Thomas; El-Rabadi, Karem; Weber, Michael

    2014-12-15

    Purpose: To determine the diagnostic performance of three-dimensional (3D) texture analysis (TA) of contrast-enhanced computed tomography (CE-CT) images for treatment response assessment in patients with Hodgkin lymphoma (HL), compared with F-18-fludeoxyglucose (FDG) positron emission tomography/CT. Methods: 3D TA of 48 lymph nodes in 29 patients was performed on venous-phase CE-CT images before and after chemotherapy. All lymph nodes showed pathologically elevated FDG uptake at baseline. A stepwise logistic regression with forward selection was performed to identify classic CT parameters and texture features (TF) that enable the separation of complete response (CR) and persistent disease. Results: The TF fraction of imagemore » in runs, calculated for the 45° direction, was able to correctly identify CR with an accuracy of 75%, a sensitivity of 79.3%, and a specificity of 68.4%. Classical CT features achieved an accuracy of 75%, a sensitivity of 86.2%, and a specificity of 57.9%, whereas the combination of TF and CT imaging achieved an accuracy of 83.3%, a sensitivity of 86.2%, and a specificity of 78.9%. Conclusions: 3D TA of CE-CT images is potentially useful to identify nodal residual disease in HL, with a performance comparable to that of classical CT parameters. Best results are achieved when TA and classical CT features are combined.« less

  16. Projection-data based temporal maximum attenuation computed tomography: determination of internal target volume for lung cancer against intra-fraction motion

    NASA Astrophysics Data System (ADS)

    Mori, Shinichiro; Kanematsu, Nobuyuki; Asakura, Hiroshi; Endo, Masahiro

    2007-02-01

    The concept of internal target volume (ITV) is highly significant in radiotherapy for the lung, an organ which is hampered by organ motion. To date, different methods to obtain the ITV have been published and are therefore available. To define ITV, we developed a new method by adapting a time filter to the four-dimensional CT scan technique (4DCT) which is projection-data processing (4D projection data maximum attenuation (4DPM)), and compared it with reconstructed image processing (4D image maximum intensity projection (4DIM)) using a phantom and clinical evaluations. 4DIM and 4DPM captured accurate maximum intensity volume (MIV), that is tumour encompassing volume, easily. Although 4DIM increased the CT number 1.8 times higher than 4DPM, 4DPM provided the original tumour CT number for MIV via a reconstruction algorithm. In the patient with lung fibrosis honeycomb, the MIV with 4DIM is 0.7 cm larger than that for cine imaging in the cranio-caudal direction. 4DPM therefore provided an accurate MIV independent of patient characteristics and reconstruction conditions. These findings indicate the usefulness of 4DPM in determining ITV in radiotherapy.

  17. Determination of effective doses in image-guided radiation therapy system

    NASA Astrophysics Data System (ADS)

    Pyone, Y. Y.; Suriyapee, S.; Sanghangthum, T.; Oonsiri, S.; Tawonwong, T.

    2016-03-01

    The organ and effective doses in image-guided radiotherapy system are determined in this study. For 2D imaging, incident air kerma (Ki) was measured by 6cc ionization chamber with Accu-Pro dosimeter. The entrance surface air kerma (ESAK) was calculated by multiplying Ki with backscatter factor. The effective dose was calculated by multiplying ESAK with conversion coefficient. For 3D imaging, computed tomography/cone-beam dose index (CTDI/CBDI) measurements were performed by using 100mm pencil ionization chamber with Accu-Pro dosimeter. The dose index in air and in CTDI phantom from planning CT and cone- beam CT were measured. Then, effective dose was calculated by ImPACT software. The effective doses from 2D conventional simulator for anteroposterior and lateral projections were 01 and 0.02mSv for head, 0.15 and 0.16mSv for thorax, 0.22 and 0.21mSv for pelvis, respectively. The effective doses from 3D, planning CT and CBCT, were 3.3 and 0.1mSv for head, 13 and 2.4mSv for thorax and 7.2 and 4.9mSv for pelvis, respectively. Based on 30 fractions of treatment course, total effective dose (3D CT, 2D setup verification and 6 times CBCT) of head, thorax and pelvis were 3.93, 27.71 and 37.03mSv, respectively. Therefore, IGRT should be administered with significant parameters to reduce the dose.

  18. Combined training (strength plus aerobic) potentiates a reduction in body fat but only functional training reduced low-density lipoprotein cholesterol in postmenopausal women with a similar training load.

    PubMed

    Rossi, Fabrício Eduardo; Fortaleza, Ana Claudia S; Neves, Lucas M; Diniz, Tiego A; de Castro, Marcela R; Buonani, Camila; Mota, Jorge; Freitas, Ismael F

    2017-06-01

    The aim of this study was to compare the effects of combined (CT; strength plus aerobic) and functional training (FT) on the body composition and metabolic profile with a similar training load in postmenopausal women. The participants were divided into three groups: CT (n=20), FT (n=17), and control group (CG, n=15). The trunk FM, fat mass (FM), percentage of FM (FM%), and fat-free mass were estimated by dual-energy X-ray absorptiometry. The metabolic profile, glucose, triacylglycerol, total cholesterol, high-density lipoprotein cholesterol and low-density lipoprotein cholesterol (LDL-c) were assessed. There were main effects of time in trunk fat, FM, and FM% ( P <0.05). There were statistically significant interaction for FM ( P =0.015), FM% ( P =0.017) with lower values for CT group. For LDL-c, there was significant interaction ( P =0.002) with greater values for FT group in relation to CG and CT. Furthermore, when performed the post hoc test on the "mean absolute differences" (Δ), it can observed statistically significant difference between FT, CT, and CG (-13.0±16.5 mg/dL vs. 4.8±18.4 mg/dL vs. 9.2±18.8 mg/dL, P <0.05). In conclusion, when training loads are equivalent CT potentiated a reduction in FM and FM%, however, only FT reduced LDL-c in postmenopausal women.

  19. Sci—Thur AM: YIS - 01: Dosimetric Analysis of Respiratory Induced Cardiac Intrafraction Motion in Left-sided Breast Cancer Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El-Sherif, O; Xhaferllari, I; Patrick, J

    2014-08-15

    Introduction: Long-term cardiac side effects in left-sided breast cancer patients (BREL) after post-operative radiotherapy has become one of the most debated issues in radiation oncology. Through breathing-adapted radiotherapy the volume of the heart exposed to radiation can be significantly reduced by delivering the radiation only at the end of inspiration phase of the respiratory cycle, this is referred to as inspiration gating (IG). The purpose of this study is to quantify the potential reduction in cardiac exposure during IG compared to conventional BREL radiotherapy and to assess the dosimetric impact of cardiac motion due to natural breathing. Methods: 24 BRELmore » patients treated with tangential parallel opposed photon beams were included in this study. All patients received a standard fast helical planning CT (FH-CT) and a 4D-CT. Treatment plans were created on the FH-CT using a clinical treatment planning system. The original treatment plan was then superimposed onto the end of inspiration CT and all 10 phases of the 4D-CT to quantify the dosimetric impact of respiratory motion and IG through 4D dose accumulation. Results: Through IG the mean dose to the heart, left ventricle, and left anterior descending artery (LAD) can be reduced in comparison to the clinical standard BREL treatment by as much as 8.39%, 10.11%, and 13.71% respectively (p < 0.05). Conclusion: Failure to account for respiratory motion can lead to under or overestimation in the calculated DVH for the heart, and it's sub-structures. IG can reduce cardiac exposure especially to the LAD during BREL radiotherapy.« less

  20. Accumulated Dose in Liver Stereotactic Body Radiotherapy: Positioning, Breathing, and Deformation Effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Velec, Michael, E-mail: michael.velec@rmp.uhn.on.ca; Institute of Medical Science, University of Toronto, Toronto, ON; Moseley, Joanne L.

    2012-07-15

    Purpose: To investigate the accumulated dose deviations to tumors and normal tissues in liver stereotactic body radiotherapy (SBRT) and investigate their geometric causes. Methods and Materials: Thirty previously treated liver cancer patients were retrospectively evaluated. Stereotactic body radiotherapy was planned on the static exhale CT for 27-60 Gy in 6 fractions, and patients were treated in free-breathing with daily cone-beam CT guidance. Biomechanical model-based deformable image registration accumulated dose over both the planning four-dimensional (4D) CT (predicted breathing dose) and also over each fraction's respiratory-correlated cone-beam CT (accumulated treatment dose). The contribution of different geometric errors to changes between themore » accumulated and predicted breathing dose were quantified. Results: Twenty-one patients (70%) had accumulated dose deviations relative to the planned static prescription dose >5%, ranging from -15% to 5% in tumors and -42% to 8% in normal tissues. Sixteen patients (53%) still had deviations relative to the 4D CT-predicted dose, which were similar in magnitude. Thirty-two tissues in these 16 patients had deviations >5% relative to the 4D CT-predicted dose, and residual setup errors (n = 17) were most often the largest cause of the deviations, followed by deformations (n = 8) and breathing variations (n = 7). Conclusion: The majority of patients had accumulated dose deviations >5% relative to the static plan. Significant deviations relative to the predicted breathing dose still occurred in more than half the patients, commonly owing to residual setup errors. Accumulated SBRT dose may be warranted to pursue further dose escalation, adaptive SBRT, and aid in correlation with clinical outcomes.« less

  1. A hybrid 3D region growing and 4D curvature analysis-based automatic abdominal blood vessel segmentation through contrast enhanced CT

    NASA Astrophysics Data System (ADS)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Shimada, Mitsuo; Iinuma, Gen

    2017-03-01

    In abdominal disease diagnosis and various abdominal surgeries planning, segmentation of abdominal blood vessel (ABVs) is a very imperative task. Automatic segmentation enables fast and accurate processing of ABVs. We proposed a fully automatic approach for segmenting ABVs through contrast enhanced CT images by a hybrid of 3D region growing and 4D curvature analysis. The proposed method comprises three stages. First, candidates of bone, kidneys, ABVs and heart are segmented by an auto-adapted threshold. Second, bone is auto-segmented and classified into spine, ribs and pelvis. Third, ABVs are automatically segmented in two sub-steps: (1) kidneys and abdominal part of the heart are segmented, (2) ABVs are segmented by a hybrid approach that integrates a 3D region growing and 4D curvature analysis. Results are compared with two conventional methods. Results show that the proposed method is very promising in segmenting and classifying bone, segmenting whole ABVs and may have potential utility in clinical use.

  2. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms.

    PubMed

    Bieniosek, Matthew F; Lee, Brian J; Levin, Craig S

    2015-10-01

    Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial "Micro Deluxe" phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. This work shows that 3D printed phantoms can be functionally equivalent to commercially available phantoms. They are a viable option for quickly distributing and fabricating low cost, customized phantoms.

  3. Improvement of spectral and axial resolutions in modified coded aperture correlation holography (COACH) imaging system

    NASA Astrophysics Data System (ADS)

    Vijayakumar, A.; Rosen, Joseph

    2017-05-01

    Coded aperture correlation holography (COACH) is a recently developed incoherent digital holographic technique. In COACH, two holograms are recorded: the object hologram for the object under study and another hologram for a point object called PSF hologram. The holograms are recorded by interfering two beams, both diffracted from the same object point, but only one of them passes through a random-like coded phase mask (CPM). The same CPM is used for recording the object as well as the PSF holograms. The image is reconstructed by correlating the object hologram with a processed version of the PSF hologram. The COACH holographic technique exhibits the same transverse and axial resolution of the regular imaging, but with the unique capability of storing 3D information. The basic COACH configuration consists of a single spatial light modulator (SLM) used for displaying the CPM. In this study, the basic COACH configuration has been advanced by employing two spatial light modulators (SLMs) in the setup. The refractive lens used in the basic COACH setup for collecting and collimating the light diffracted by the object is replaced by an SLM on which an equivalent diffractive lens is displayed. Unlike a refractive lens, the diffractive lens displayed on the first SLM focuses light with different wavelengths to different axial planes, which are separated by distances larger than the axial correlation lengths of the CPM for any visible wavelength. This characteristic extends the boundaries of COACH from three-dimensional to four-dimensional imaging with the wavelength as its fourth dimension.

  4. Preclinical Efficacy of [V4Q5]dDAVP, a Second Generation Vasopressin Analog, on Metastatic Spread and Tumor-Associated Angiogenesis in Colorectal Cancer.

    PubMed

    Garona, Juan; Sobol, Natasha T; Pifano, Marina; Segatori, Valeria I; Gomez, Daniel E; Ripoll, Giselle V; Alonso, Daniel F

    2018-06-01

    Control of metastatic spread of colorectal cancer (CRC) remains as a major therapeutic challenge. [V4Q5]dDAVP is a vasopressin peptide analog with previously reported anticancer activity against carcinoma tumors. By acting as a selective agonist of AVPR2 present in endothelial and tumor cells, [V4Q5]dDAVP is able to impair tumor aggressiveness and distant spread. Our aim was to evaluate the potential therapeutic benefits of [V4Q5]dDAVP on highly aggressive CRC disease using experimental models with translational relevance. Murine CT-26 and human Colo-205 AVPR2-expressing CRC cell lines were used to test the preclinical efficacy of [V4Q5]dDAVP, both in vitro and in vivo. In syngeneic mice surgically implanted with CT-26 cells in the spleen, sustained i.v. treatment with [V4Q5]dDAVP (0.3 µg/kg) dramatically impaired metastatic progression to liver without overt signs of toxicity, and also reduced experimental lung colonization. The compound inhibited in vivo angiogenesis driven by Colo-205 cells in athymic mice, as well as in vitro endothelial cell migration and capillary tube formation. [V4Q5]dDAVP exerted AVPR2-dependent cytostatic activity in vitro (IC50 1.08 µM) and addition to 5-FU resulted in synergistic antiproliferative effects both in CT-26 and Colo-205 cells. The present preclinical study establishes for the first time the efficacy of [V4Q5]dDAVP on CRC. These encouraging results suggest that the novel second generation vasopressin analog could be used for the management of aggressive CRC as an adjuvant agent during surgery or to complement standard chemotherapy, limiting tumor angiogenesis and metastasis and thus protecting the patient from CRC recurrence.

  5. Recombinant polymorphic membrane protein D in combination with a novel, second-generation lipid adjuvant protects against intra-vaginal Chlamydia trachomatis infection in mice.

    PubMed

    Paes, Wayne; Brown, Naj; Brzozowski, Andrzej M; Coler, Rhea; Reed, Steve; Carter, Darrick; Bland, Martin; Kaye, Paul M; Lacey, Charles J N

    2016-07-29

    The development of a chlamydial vaccine that elicits protective mucosal immunity is of paramount importance in combatting the global spread of sexually transmitted Chlamydia trachomatis (Ct) infections. While the identification and prioritization of chlamydial antigens is a crucial prerequisite for efficacious vaccine design, it is likely that novel adjuvant development and selection will also play a pivotal role in the translational potential of preclinical Ct vaccines. Although the molecular nature of the immuno-modulatory component is of primary importance, adjuvant formulation and delivery systems may also govern vaccine efficacy and potency. Our study provides the first preclinical evaluation of recombinant Ct polymorphic membrane protein D (rPmpD) in combination with three different formulations of a novel second-generation lipid adjuvant (SLA). SLA was rationally designed in silico by modification of glucopyranosyl lipid adjuvant (GLA), a TLR4 agonistic precursor molecule currently in Phase II clinical development. We demonstrate robust protection against intra-vaginal Ct challenge in mice, evidenced by significantly enhanced resistance to infection and reduction in mean bacterial load. Strikingly, protection was found to correlate with the presence of robust anti-rPmpD serum and cervico-vaginal IgG titres, even in the absence of adjuvant-induced Th1-type cellular immune responses elicited by each SLA formulation, and we further show that anti-rPmpD antibodies recognize Ct EBs. These findings highlight the utility of SLA and rational molecular design of adjuvants in preclinical Ct vaccine development, but also suggest an important role for anti-rPmpD antibodies in protection against urogenital Ct infection. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  6. A novel four-dimensional radiotherapy planning strategy from a tumor-tracking beam's eye view

    NASA Astrophysics Data System (ADS)

    Li, Guang; Cohen, Patrice; Xie, Huchen; Low, Daniel; Li, Diana; Rimner, Andreas

    2012-11-01

    To investigate the feasibility of four-dimensional radiotherapy (4DRT) planning from a tumor-tracking beam's eye view (ttBEV) with reliable gross tumor volume (GTV) delineation, realistic normal tissue representation, high planning accuracy and low clinical workload, we propose and validate a novel 4D conformal planning strategy based on a synthesized 3.5D computed tomographic (3.5DCT) image with a motion-compensated tumor. To recreate patient anatomy from a ttBEV in the moving tumor coordinate system for 4DRT planning (or 4D planning), the centers of delineated GTVs in all phase CT images of 4DCT were aligned, and then the aligned CTs were averaged to produce a new 3.5DCT image. This GTV-motion-compensated CT contains a motionless target (with motion artifacts minimized) and motion-blurred normal tissues (with a realistic temporal density average). Semi-automatic threshold-based segmentation of the tumor, lung and body was applied, while manual delineation was used for other organs at risk (OARs). To validate this 3.5DCT-based 4D planning strategy, five patients with peripheral lung lesions of small size (<5 cm3) and large motion range (1.2-3.5 cm) were retrospectively studied for stereotactic body radiotherapy (SBRT) using 3D conformal radiotherapy planning tools. The 3.5DCT-based 4D plan (3.5DCT plan) with 9-10 conformal beams was compared with the 4DCT-based 4D plan (4DCT plan). The 4DCT plan was derived from multiple 3D plans based on all phase CT images, each of which used the same conformal beam configuration but with an isocenter shift to aim at the moving tumor and a minor beam aperture and weighting adjustment to maintain plan conformality. The dose-volume histogram (DVH) of the 4DCT plan was created with two methods: one is an integrated DVH (iDVH4D), which is defined as the temporal average of all 3D-phase-plan DVHs, and the other (DVH4D) is based on the dose distribution in a reference phase CT image by dose warping from all phase plans using the displacement vector field (DVF) from a free-form deformable image registration (DIR). The DVH3.5D (for the 3.5DCT plan) was compared with both iDVH4D and DVH4D. To quantify the DVH difference between the 3.5DCT plan and the 4DCT plan, two methods were used: relative difference (%) of the areas underneath the DVH curves and the volumes receiving more than 20% (V20) and 50% (V50) of prescribed dose of these 4D plans. The volume of the delineated GTV from different phase CTs varied dramatically from 24% to 112% among the five patients, whereas the GTV from 3.5DCT deviated from the averaged GTV in 4DCT by only -6%±6%. For planning tumor volume (PTV) coverage, the difference between the DVH3.5D and iDVH4D was negligible (<1% area), whereas the DVH3.5D and DVH4D were quite different, due to DIR uncertainty (˜2 mm), which propagates to PTV dose coverage with a pronounced uncertainty for small tumors (0.3-4.0 cm3) in stereotactic plans with sharp dose falloff around PTV. For OARs, such as the lung, heart, cord and esophagus, the three DVH curves (DVH3.5D, DVH4D and iDVH4D) were found to be almost identical for the same patients, especially in high-dose regions. For the tumor-containing lung, the relative difference of the areas underneath the DVH curves was found to be small (5.3% area on average), of which 65% resulted from the low-dose region (D < 20%). The averaged V20 difference between the two 4D plans was 1.2% ± 0.8%. For the mean lung dose (MLD), the 3.5DCT plan differed from the 4DCT plan by -1.1%±1.3%. GTV-motion-compensated CT (3.5DCT) produces an accurate and reliable GTV delineation, which is close to the mean GTV from 4DCT. The 3.5DCT plan is equivalent to the 4DCT plan with <1% dose difference to the PTV and negligible dose difference in OARs. The 3.5DCT approach simplifies 4D planning and provides accurate dose calculation without a substantial increase of clinical workload for motion-tracking delivery to treat small peripheral lung tumors with large motion.

  7. A phase 3 trial of the efficacy and safety of oral recombinant calcitonin: the Oral Calcitonin in Postmenopausal Osteoporosis (ORACAL) trial.

    PubMed

    Binkley, Neil; Bolognese, Michael; Sidorowicz-Bialynicka, Anna; Vally, Tasneem; Trout, Richard; Miller, Colin; Buben, Christine E; Gilligan, James P; Krause, David S

    2012-08-01

    The Oral Calcitonin in Postmenopausal Osteoporosis (ORACAL) study was a randomized, double-blind, double-dummy, active- and placebo-controlled, multiple-dose, phase 3 study to assess the efficacy and safety of oral recombinant calcitonin for treatment of postmenopausal osteoporosis. A total of 565 women age 46 to 86 (mean 66.5) years were randomized (4:3:2) to receive oral recombinant salmon calcitonin (rsCT) tablets (0.2  mg/d) plus placebo nasal spray, synthetic salmon calcitonin (ssCT) nasal spray (200 IU/d) plus placebo tablets, or placebo (placebo tablets plus placebo nasal spray), respectively for 48 weeks. All women received calcium (≥1000  mg/d) and vitamin D (800 IU/d). Women randomized to oral rsCT had a mean ± SD percent increase from baseline in lumbar spine bone mineral density (BMD) (1.5% ± 3.2%) that was greater than those randomized to ssCT nasal spray (0.78% ± 2.9%) or placebo (0.5% ± 3.2%). Lumbar spine BMD change in those receiving nasal calcitonin did not differ from placebo. Oral rsCT treatment also resulted in greater improvements in trochanteric and total proximal femur BMD than ssCT nasal spray. Reductions in bone resorption markers with oral rsCT were greater than those observed in ssCT nasal spray or placebo recipients. Approximately 80% of subjects in each treatment group experienced an adverse event, the majority of which were mild or moderate in intensity. Gastrointestinal system adverse events were reported by nearly one-half of women in all treatment groups and were the principal reason for premature withdrawals. Less than 10% of women experienced a serious adverse event and no deaths occurred. Overall, oral rsCT was superior to nasal ssCT and placebo for increasing BMD and reducing bone turnover. Oral rsCT was safe and as well tolerated as ssCT nasal spray or placebo. Oral calcitonin may provide an additional treatment alternative for women with postmenopausal osteoporosis. Copyright © 2012 American Society for Bone and Mineral Research.

  8. A 4DCT imaging-based breathing lung model with relative hysteresis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyawaki, Shinjiro; Choi, Sanghun; Hoffman, Eric A.

    To reproduce realistic airway motion and airflow, the authors developed a deforming lung computational fluid dynamics (CFD) model based on four-dimensional (4D, space and time) dynamic computed tomography (CT) images. A total of 13 time points within controlled tidal volume respiration were used to account for realistic and irregular lung motion in human volunteers. Because of the irregular motion of 4DCT-based airways, we identified an optimal interpolation method for airway surface deformation during respiration, and implemented a computational solid mechanics-based moving mesh algorithm to produce smooth deforming airway mesh. In addition, we developed physiologically realistic airflow boundary conditions for bothmore » models based on multiple images and a single image. Furthermore, we examined simplified models based on one or two dynamic or static images. By comparing these simplified models with the model based on 13 dynamic images, we investigated the effects of relative hysteresis of lung structure with respect to lung volume, lung deformation, and imaging methods, i.e., dynamic vs. static scans, on CFD-predicted pressure drop. The effect of imaging method on pressure drop was 24 percentage points due to the differences in airflow distribution and airway geometry. - Highlights: • We developed a breathing human lung CFD model based on 4D-dynamic CT images. • The 4DCT-based breathing lung model is able to capture lung relative hysteresis. • A new boundary condition for lung model based on one static CT image was proposed. • The difference between lung models based on 4D and static CT images was quantified.« less

  9. Imaging a moving lung tumor with megavoltage cone beam computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gayou, Olivier, E-mail: ogayou@wpahs.org; Colonias, Athanasios

    2015-05-15

    Purpose: Respiratory motion may affect the accuracy of image guidance of radiation treatment of lung cancer. A cone beam computed tomography (CBCT) image spans several breathing cycles, resulting in a blurred object with a theoretical size equal to the sum of tumor size and breathing motion. However, several factors may affect this theoretical relationship. The objective of this study was to analyze the effect of tumor motion on megavoltage (MV)-CBCT images, by comparing target sizes on simulation and pretreatment images of a large cohort of lung cancer patients. Methods: Ninety-three MV-CBCT images from 17 patients were analyzed. Internal target volumesmore » were contoured on each MV-CBCT dataset [internal target volume (ITV{sub CB})]. Their extent in each dimension was compared to that of two volumes contoured on simulation 4-dimensional computed tomography (4D-CT) images: the combination of the tumor contours of each phase of the 4D-CT (ITV{sub 4D}) and the volume contoured on the average CT calculated from the 4D-CT phases (ITV{sub ave}). Tumor size and breathing amplitude were assessed by contouring the tumor on each CBCT raw projection where it could be unambiguously identified. The effect of breathing amplitude on the quality of the MV-CBCT image reconstruction was analyzed. Results: The mean differences between the sizes of ITV{sub CB} and ITV{sub 4D} were −1.6 ± 3.3 mm (p < 0.001), −2.4 ± 3.1 mm (p < 0.001), and −7.2 ± 5.3 mm (p < 0.001) in the anterior/posterior (AP), left/right (LR), and superior/inferior (SI) directions, respectively, showing that MV-CBCT underestimates the full target size. The corresponding mean differences between ITV{sub CB} and ITV{sub ave} were 0.3 ± 2.6 mm (p = 0.307), 0.0 ± 2.4 mm (p = 0.86), and −4.0 ± 4.3 mm (p < 0.001), indicating that the average CT image is more representative of what is visible on MV-CBCT in the AP and LR directions. In the SI directions, differences between ITV{sub CB} and ITV{sub ave} could be separated into two groups based on tumor motion: −3.2 ± 3.2 mm for tumor motion less than 15 mm and −10.9 ± 6.3 mm for tumor motion greater than 15 mm. Deviations of measured target extents from their theoretical values derived from tumor size and motion were correlated with motion amplitude similarly for both MV-CBCT and average CT images, suggesting that the two images were subject to similar motion artifacts for motion less than 15 mm. Conclusions: MV-CBCT images are affected by tumor motion and tend to under-represent the full target volume. For tumor motion up to 15 mm, the volume contoured on average CT is comparable to that contoured on the MV-CBCT. Therefore, the average CT should be used in image registration for localization purposes, and the standard 5 mm PTV margin seems adequate. For tumor motion greater than 15 mm, an additional setup margin may need to be used to account for the increased uncertainty in tumor localization.« less

  10. Coaching Patients Saves Lives and Money.

    PubMed

    Byrnes, Joshua; Elliott, Thomas; Vale, Margarite J; Jelinek, Michael V; Scuffham, Paul

    2018-04-01

    The Coaching On Achieving Cardiovascular Health (COACH) Program has been proven to improve biomedical and lifestyle cardiovascular disease (CVD) risk factors. The objective of this study was to evaluate the long-term impact of The COACH Program on overall survival, hospital utilization, and costs from the perspective of a private health insurer (payor), in patients with CVD. A prospective parallel-group case-control study design with controls randomly matched to patients based on propensity score. There were 512 participants with CVD engaged in a structured disease management program of 6 months duration (The COACH Program) who were matched to 512 patients with CVD who were allocated to the control group. The independent variables that estimated the propensity score were preprogram hospital admissions, age, and sex. The primary outcome was overall survival with secondary outcomes, including hospital utilization and cost incurred by the private health insurer. Mean follow-up was 6.35 years. Difference in overall survival between the 2 groups was estimated using a Cox proportional hazard ratio (HR) with difference in total cost estimated using a generalized linear model. The COACH Program achieved a significant reduction in overall mortality (HR 0.70; 95% confidence interval [CI], 0.53-0.93; P = .014). There was an apparent dose-response effect: those who received up to 3 coaching sessions had no decrease in mortality (HR 1.02; 95% CI, 0.69-1.49; P = .926); those who received 4 or more coaching sessions had a substantial decrease in mortality (HR 0.58; 95% CI, 0.42-0.81; P = .001). Total cost to the health insurer was substantially lower in the intervention group ($12,707 per person lower; P = .078). The reduction in total cost was significantly greater in those who received 4 or more sessions ($19,418 per person; P = .006) and in males ($18,947 per person; P = .029). Those enrolled in The COACH program achieved a statistically significant decrease in overall mortality compared with usual care at 6.35 years. A substantive reduction in hospital costs was also observed among those who received The COACH program compared with those who did not, particularly in those who received 4 or more sessions and in males. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Development and validation of automated 2D-3D bronchial airway matching to track changes in regional bronchial morphology using serial low-dose chest CT scans in children with chronic lung disease.

    PubMed

    Raman, Pavithra; Raman, Raghav; Newman, Beverley; Venkatraman, Raman; Raman, Bhargav; Robinson, Terry E

    2010-12-01

    To address potential concern for cumulative radiation exposure with serial spiral chest computed tomography (CT) scans in children with chronic lung disease, we developed an approach to match bronchial airways on low-dose spiral and low-dose high-resolution CT (HRCT) chest images to allow serial comparisons. An automated algorithm matches the position and orientation of bronchial airways obtained from HRCT slices with those in the spiral CT scan. To validate this algorithm, we compared manual matching vs automatic matching of bronchial airways in three pediatric patients. The mean absolute percentage difference between the manually matched spiral CT airway and the index HRCT airways were 9.4 ± 8.5% for the internal diameter measurements, 6.0 ± 4.1% for the outer diameter measurements, and 10.1 ± 9.3% for the wall thickness measurements. The mean absolute percentage difference between the automatically matched spiral CT airway measurements and index HRCT airway measurements were 9.2 ± 8.6% for the inner diameter, 5.8 ± 4.5% for the outer diameter, and 9.9 ± 9.5% for the wall thickness. The overall difference between manual and automated methods was 2.1 ± 1.2%, which was significantly less than the interuser variability of 5.1 ± 4.6% (p<0.05). Tests of equivalence had p<0.05, demonstrating no significant difference between the two methods. The time required for matching was significantly reduced in the automated method (p<0.01) and was as accurate as manual matching, allowing efficient comparison of airways obtained on low-dose spiral CT imaging with low-dose HRCT scans.

  12. Use of a Connected Glucose Meter and Certified Diabetes Educator Coaching to Decrease the Likelihood of Abnormal Blood Glucose Excursions: The Livongo for Diabetes Program.

    PubMed

    Downing, Janelle; Bollyky, Jenna; Schneider, Jennifer

    2017-07-11

    The Livongo for Diabetes Program offers members (1) a cellular technology-enabled, two-way messaging device that measures blood glucose (BG), centrally stores the glucose data, and delivers messages back to the individual in real time; (2) unlimited BG test strips; and (3) access to a diabetes coaching team for questions, goal setting, and automated support for abnormal glucose excursions. The program is sponsored by at-risk self-insured employers, health plans and provider organizations where it is free to members with diabetes or it is available directly to the person with diabetes where they cover the cost. The objective of our study was to evaluate BG data from 4544 individuals with diabetes who were enrolled in the Livongo program from October 2014 through December 2015. Members used the Livongo glucose meter to measure their BG levels an average of 1.8 times per day. We estimated the probability of having a day with a BG reading outside of the normal range (70-180 mg/dL, or 3.9-10.0 mmol/L) in months 2 to 12 compared with month 1 of the program, using individual fixed effects to control for individual characteristics. Livongo members experienced an average 18.4% decrease in the likelihood of having a day with hypoglycemia (BG <70 mg/dL) and an average 16.4% decrease in hyperglycemia (BG >180 mg/dL) in months 2-12 compared with month 1 as the baseline. The biggest impact was seen on hyperglycemia for nonusers of insulin. We do not know all of the contributing factors such as medication or other treatment changes during the study period. These findings suggest that access to a connected glucose meter and certified diabetes educator coaching is associated with a decrease in the likelihood of abnormal glucose excursions, which can lead to diabetes-related health care savings. ©Janelle Downing, Jenna Bollyky, Jennifer Schneider. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 11.07.2017.

  13. A Multifaceted School-based Intervention to Reduce Risk for Type 2 Diabetes in At-Risk Youth

    PubMed Central

    Grey, Margaret; Jaser, Sarah S.; Holl, Marita G.; Jefferson, Vanessa; Dziura, James; Northrup, Veronika

    2009-01-01

    Objective To evaluate the impact of a multifaceted, school-based intervention on inner city youth at high risk for type 2 diabetes mellitus (T2DM) and to determine whether the addition of coping skills training (CST) and health coaching improves outcomes. Method 198 students in New Haven, CT at risk for T2DM (BMI > 85th percentile and family history of diabetes) were randomized by school to an educational intervention with or without the addition of CST and health coaching. Students were enrolled from 2004–2007 and followed for 12 months. Results Students in both groups showed some improvement in anthropometric measures, lipids, and depressive symptoms over 12 months. BMI was not improved by the intervention. Students who received CST showed greater improvement on some indicators of metabolic risk than students who received education only. Conclusion A multifaceted, school-based intervention may hold promise for reducing metabolic risk in urban, minority youth. PMID:19643125

  14. The effect of coach and player injury knowledge, attitudes and beliefs on adherence to the FIFA 11+ programme in female youth soccer.

    PubMed

    McKay, Carly D; Steffen, Kathrin; Romiti, Maria; Finch, Caroline F; Emery, Carolyn A

    2014-09-01

    Injury knowledge and beliefs influence uptake of prevention programmes, but the relationship between knowledge, beliefs and adherence remains unclear. To describe injury knowledge and beliefs among youth female soccer coaches and players, and to identify the relationship between these factors, different delivery strategies of the FIFA 11+ programme and adherence. A subcohort analysis from a cluster-randomised controlled trial of 31 female soccer teams (coaches n=29, players (ages 13-18) n=258). Preseason and postseason questionnaires were used to assess knowledge and beliefs. Teams recorded FIFA 11+ adherence during the season. At baseline, 62.8% (95% CI 48.4% to 77.3%) of coaches and 75.8% (95% CI 71.5% to 80.1%) of players considered 'inadequate warm-up' a risk factor for injury. There was no effect of delivery method (OR=1.1; 95% CI 0.8 to 1.5) or adherence (OR=1.0; 95% CI 0.9 to 1.1) on this belief. At baseline, 13.8% (95% CI 1.3% to 26.4%) of coaches believed a warm-up could prevent muscle injuries, but none believed it could prevent knee and ankle injuries. For players, 9.7% (95% CI 6.1% to 13.3%), 4.7% (95% CI 2.1% to 7.3%) and 4.7% (95% CI 2.1% to 7.3%) believed a warm-up would prevent muscle, knee and ankle injuries, respectively. Years of playing experience were negatively associated with high adherence for coaches (OR=0.93; 0.88 to 0.99) and players (OR=0.92; 0.85 to 0.98). There were gaps in injury knowledge and beliefs, which differed for coaches and players. Beliefs did not significantly affect adherence to the FIFA 11+, suggesting additional motivational factors should be considered. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Voluntary Deep Inspiration Breath-hold Reduces the Heart Dose Without Compromising the Target Volume Coverage During Radiotherapy for Left-sided Breast Cancer.

    PubMed

    Al-Hammadi, Noora; Caparrotti, Palmira; Naim, Carole; Hayes, Jillian; Rebecca Benson, Katherine; Vasic, Ana; Al-Abdulla, Hissa; Hammoud, Rabih; Divakar, Saju; Petric, Primoz

    2018-03-01

    During radiotherapy of left-sided breast cancer, parts of the heart are irradiated, which may lead to late toxicity. We report on the experience of single institution with cardiac-sparing radiotherapy using voluntary deep inspiration breath hold (V-DIBH) and compare its dosimetric outcome with free breathing (FB) technique. Left-sided breast cancer patients, treated at our department with postoperative radiotherapy of breast/chest wall +/- regional lymph nodes between May 2015 and January 2017, were considered for inclusion. FB-computed tomography (CT) was obtained and dose-planning performed. Cases with cardiac V25Gy ≥ 5% or risk factors for heart disease were coached for V-DIBH. Compliant patients were included. They underwent additional CT in V-DIBH for planning, followed by V-DIBH radiotherapy. Dose volume histogram parameters for heart, lung and optimized planning target volume (OPTV) were compared between FB and BH. Treatment setup shifts and systematic and random errors for V-DIBH technique were compared with FB historic control. Sixty-three patients were considered for V-DIBH. Nine (14.3%) were non-compliant at coaching, leaving 54 cases for analysis. When compared with FB, V-DIBH resulted in a significant reduction of mean cardiac dose from 6.1 +/- 2.5 to 3.2 +/- 1.4 Gy (p < 0.001), maximum cardiac dose from 51.1 +/- 1.4 to 48.5 +/- 6.8 Gy (p = 0.005) and cardiac V25Gy from 8.5 +/- 4.2 to 3.2 +/- 2.5% (p < 0.001). Heart volumes receiving low (10-20 Gy) and high (30-50 Gy) doses were also significantly reduced. Mean dose to the left anterior coronary artery was 23.0 (+/- 6.7) Gy and 14.8 (+/- 7.6) Gy on FB and V-DIBH, respectively (p < 0.001). Differences between FB- and V-DIBH-derived mean lung dose (11.3 +/- 3.2 vs. 10.6 +/- 2.6 Gy), lung V20Gy (20.5 +/- 7 vs. 19.5 +/- 5.1 Gy) and V95% for the OPTV (95.6 +/- 4.1 vs. 95.2 +/- 6.3%) were non-significant. V-DIBH-derived mean shifts for initial patient setup were ≤ 2.7 mm. Random and systematic errors were ≤ 2.1 mm. These results did not differ significantly from historic FB controls. When compared with FB, V-DIBH demonstrated high setup accuracy and enabled significant reduction of cardiac doses without compromising the target volume coverage. Differences in lung doses were non-significant.

  16. Unusual x-ray excited luminescence spectra of NiO suggest self-trapping of the d-d charge-transfer exciton

    NASA Astrophysics Data System (ADS)

    Sokolov, V. I.; Pustovarov, V. A.; Churmanov, V. N.; Ivanov, V. Yu.; Gruzdev, N. B.; Sokolov, P. S.; Baranov, A. N.; Moskvin, A. S.

    2012-09-01

    Luminescence spectra of NiO have been investigated under vacuum ultraviolet (VUV) and soft x-ray (XUV) excitation (DESY, Hamburg). Photoluminescence (PL) spectra show broad emission violet and green bands centered at about 3.2 and 2.6 eV, respectively. The PL excitation (PLE) spectral evolution and lifetime measurements reveal that the two mechanisms with short and long decay times, attributed to the d(eg)-d(eg) and p(π)-d charge transfer (CT) transitions in the range 4-6 eV, respectively, are responsible for the observed emissions. The XUV excitation makes it possible to avoid the predominant role of the surface effects in luminescence and reveals a bulk violet luminescence with a puzzling well-isolated doublet of very narrow lines. These lines with close energies near 3.3 eV are attributed to recombination transitions in the self-trapped d-d CT excitons formed by the coupled Jahn-Teller Ni+ and Ni3+ centers. The conclusion is supported by a comparative analysis of the luminescence spectra for NiO and solid solution NixZn1-xO and by a comprehensive cluster model assignment of different p-d and d-d CT transitions and their relaxation channels. Our paper shows that the time-resolved luminescence measurements provide an instructive tool for the elucidation of the p-d and d-d CT excitations and their relaxation in 3d oxides.

  17. Helical CT scan with 2D and 3D reconstructions and virtual endoscopy versus conventional endoscopy in the assessment of airway disease in neonates, infants and children.

    PubMed

    Yunus, Mahira

    2012-11-01

    To study the use of helical computed tomography 2-D and 3-D images, and virtual endoscopy in the evaluation of airway disease in neonates, infants and children and its value in lesion detection, characterisation and extension. Conducted at Al-Noor Hospital, Makkah, Saudi Arabia, from January 1 to June 30, 2006, the study comprised of 40 patients with strider, having various causes of airway obstruction. They were examined by helical CT scan with 2-D and 3-D reconstructions and virtual endoscopy. The level and characterisation of lesions were carried out and results were compared with actual endoscopic findings. Conventional endoscopy was chosen as the gold standard, and the evaluation of endoscopy was done in terms of sensitivity and specificity of the procedure. For statistical purposes, SPSS version 10 was used. All CT methods detected airway stenosis or obstruction. Accuracy was 98% (n=40) for virtual endoscopy, 96% (n=48) for 3-D external rendering, 90% (n=45) for multiplanar reconstructions and 86% (n=43) for axial images. Comparing the results of 3-D internal and external volume rendering images with conventional endoscopy for detection and grading of stenosis were closer than with 2-D minimum intensity multiplanar reconstruction and axial CT slices. Even high-grade stenosis could be evaluated with virtual endoscope through which conventional endoscope cannot be passed. A case of 4-year-old patient with tracheomalacia could not be diagnosed by helical CT scan and virtual bronchoscopy which was diagriosed on conventional endoscopy and needed CT scan in inspiration and expiration. Virtual endoscopy [VE] enabled better assessment of stenosis compared to the reading of 3-D external rendering, 2-D multiplanar reconstruction [MPR] or axial slices. It can replace conventional endoscopy in the assessment of airway disease without any additional risk.

  18. Learning distance function for regression-based 4D pulmonary trunk model reconstruction estimated from sparse MRI data

    NASA Astrophysics Data System (ADS)

    Vitanovski, Dime; Tsymbal, Alexey; Ionasec, Razvan; Georgescu, Bogdan; Zhou, Shaohua K.; Hornegger, Joachim; Comaniciu, Dorin

    2011-03-01

    Congenital heart defect (CHD) is the most common birth defect and a frequent cause of death for children. Tetralogy of Fallot (ToF) is the most often occurring CHD which affects in particular the pulmonary valve and trunk. Emerging interventional methods enable percutaneous pulmonary valve implantation, which constitute an alternative to open heart surgery. While minimal invasive methods become common practice, imaging and non-invasive assessment tools become crucial components in the clinical setting. Cardiac computed tomography (CT) and cardiac magnetic resonance imaging (cMRI) are techniques with complementary properties and ability to acquire multiple non-invasive and accurate scans required for advance evaluation and therapy planning. In contrary to CT which covers the full 4D information over the cardiac cycle, cMRI often acquires partial information, for example only one 3D scan of the whole heart in the end-diastolic phase and two 2D planes (long and short axes) over the whole cardiac cycle. The data acquired in this way is called sparse cMRI. In this paper, we propose a regression-based approach for the reconstruction of the full 4D pulmonary trunk model from sparse MRI. The reconstruction approach is based on learning a distance function between the sparse MRI which needs to be completed and the 4D CT data with the full information used as the training set. The distance is based on the intrinsic Random Forest similarity which is learnt for the corresponding regression problem of predicting coordinates of unseen mesh points. Extensive experiments performed on 80 cardiac CT and MR sequences demonstrated the average speed of 10 seconds and accuracy of 0.1053mm mean absolute error for the proposed approach. Using the case retrieval workflow and local nearest neighbour regression with the learnt distance function appears to be competitive with respect to "black box" regression with immediate prediction of coordinates, while providing transparency to the predictions made.

  19. SU-E-T-424: Feasibility of 3D Printed Radiological Equivalent Customizable Tissue Like Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, D; Ferreira, C; Ahmad, S

    Purpose: To investigate the feasibility of 3D printing CT# specific radiological equivalent tissue like materials. Methods: A desktop 3D printer was utilized to create a series of 3 cm x 3 cm x 2 cm PLA plastic blocks of varying fill densities. The fill pattern was selected to be hexagonal (Figure 1). A series of blocks was filled with paraffin and compared to a series filled with air. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the centers of the materials was determined. The attenuation properties of the subsequent blocks were alsomore » evaluated through their isocentric irradiation via “TrueBeam” accelerator under six beam energies. Blocks were placed upon plastic-water slabs of 4 cm in thickness assuring electronic equilibrium and data was collected via Sun Nuclear “Edge” diode detector. Relative changes in dose were compared with those predicted by Varian “Eclipse” TPS. Results: The CT# of 3D printed blocks was found to be a controllable variable. The fill material was able to narrow the range of variability in each sample. The attenuation of the block tracked with the density of the total fill structure. Assigned CT values in the TPS were seen to fall within an expected range predicted by the CT scans of the 3D printed blocks. Conclusion: We have demonstrated that it is possible to 3D print materials of varying tissue equivalencies, and that these materials have radiological properties that are customizable and predictable.« less

  20. CT-guided Irreversible Electroporation in an Acute Porcine Liver Model: Effect of Previous Transarterial Iodized Oil Tissue Marking on Technical Parameters, 3D Computed Tomographic Rendering of the Electroporation Zone, and Histopathology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Fritz, S., E-mail: stefan.fritz@med.uni-heidelberg.de; Vollherbst, D., E-mail: dominikvollherbst@web.de

    PurposeTo evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential strategy to improve IRE performance.MethodsAfter Ethics Committee approval was obtained, in five landrace pigs, two IREs of the right and left liver (RL and LL) were performed under CT guidance with identical electroporation parameters. Before IRE, transarterial marking of the LL was performed with iodized oil. Nonenhanced and contrast-enhanced CT examinations followed. One hour after IRE, animals were killedmore » and livers collected. Mean resulting voltage and amperage during IRE were assessed. For 3D CT rendering of the electroporation zone, parameters for size and shape were analyzed. Quantitative data were compared by the Mann–Whitney test. Histopathological differences were assessed.ResultsMean resulting voltage and amperage were 2,545.3 ± 66.0 V and 26.1 ± 1.8 A for RL, and 2,537.3 ± 69.0 V and 27.7 ± 1.8 A for LL without significant differences. Short axis, volume, and sphericity index were 16.5 ± 4.4 mm, 8.6 ± 3.2 cm{sup 3}, and 1.7 ± 0.3 for RL, and 18.2 ± 3.4 mm, 9.8 ± 3.8 cm{sup 3}, and 1.7 ± 0.3 for LL without significant differences. For RL and LL, the electroporation zone consisted of severely widened hepatic sinusoids containing erythrocytes and showed homogeneous apoptosis. For LL, iodized oil could be detected in the center and at the rim of the electroporation zone.ConclusionThere is no adverse effect of previous ITM on technical parameters, 3D CT rendering of the electroporation zone, and histopathology after CT-guided IRE of the liver.« less

  1. Effect of Coaching to Increase Water Intake on Kidney Function Decline in Adults With Chronic Kidney Disease: The CKD WIT Randomized Clinical Trial.

    PubMed

    Clark, William F; Sontrop, Jessica M; Huang, Shih-Han; Gallo, Kerri; Moist, Louise; House, Andrew A; Cuerden, Meaghan S; Weir, Matthew A; Bagga, Amit; Brimble, Scott; Burke, Andrew; Muirhead, Norman; Pandeya, Sanjay; Garg, Amit X

    2018-05-08

    In observational studies, increased water intake is associated with better kidney function. To determine the effect of coaching to increase water intake on kidney function in adults with chronic kidney disease. The CKD WIT (Chronic Kidney Disease Water Intake Trial) randomized clinical trial was conducted in 9 centers in Ontario, Canada, from 2013 until 2017 (last day of follow-up, May 25, 2017). Patients had stage 3 chronic kidney disease (estimated glomerular filtration rate [eGFR] 30-60 mL/min/1.73 m2 and microalbuminuria or macroalbuminuria) and a 24-hour urine volume of less than 3.0 L. Patients in the hydration group (n = 316) were coached to drink more water, and those in the control group (n = 315) were coached to maintain usual intake. The primary outcome was change in kidney function (eGFR from baseline to 12 months). Secondary outcomes included 1-year change in plasma copeptin concentration, creatinine clearance, 24-hour urine albumin, and patient-reported overall quality of health (0 [worst possible] to 10 [best possible]). Of 631 randomized patients (mean age, 65.0 years; men, 63.4%; mean eGFR, 43 mL/min/1.73 m2; median urine albumin, 123 mg/d), 12 died (hydration group [n = 5]; control group [n = 7]). Among 590 survivors with 1-year follow-up measurements (95% of 619), the mean change in 24-hour urine volume was 0.6 L per day higher in the hydration group (95% CI, 0.5 to 0.7; P < .001). The mean change in eGFR was -2.2 mL/min/1.73 m2 in the hydration group and -1.9 mL/min/1.73 m2 in the control group (adjusted between-group difference, -0.3 mL/min/1.73 m2 [95% CI, -1.8 to 1.2; P = .74]). The mean between-group differences (hydration vs control) in secondary outcomes were as follows: plasma copeptin, -2.2 pmol/L (95% CI, -3.9 to -0.5; P = .01); creatinine clearance, 3.6 mL/min/1.73 m2 (95% CI, 0.8 to 6.4; P = .01); urine albumin, 7 mg per day (95% CI, -4 to 51; P = .11); and quality of health, 0.2 points (95% CI, -0.3 to 0.3; P = .22). Among adults with chronic kidney disease, coaching to increase water intake compared with coaching to maintain the same water intake did not significantly slow the decline in kidney function after 1 year. However, the study may have been underpowered to detect a clinically important difference. clinicaltrials.gov Identifier: NCT01766687.

  2. Morphometric analysis of acetabular dysplasia in cerebral palsy: three-dimensional CT study.

    PubMed

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2009-12-01

    Three-dimensional computed tomography (3D-CT) eliminates the positioning errors and allows the clinician to more accurately assess the radiographic parameters present. To elucidate the 3D geometry of the acetabulum and the extent of hip subluxation/dislocation in patients with cerebral palsy (CP), quantitative morphometric analysis was performed using 3D-CT data. We evaluated 150 hips in 75 patients with bilateral spastic CP. The mean age of the patients was 5.4 years (range: 2.7 to 6.9 y). The fitting plane of the ilium was projected onto the coronal plane and then onto the sagittal plane, and then the angle formed with a horizontal line was defined as CTalpha (the lateral opening angle) and CTbeta (the sagittal inclination angle), respectively. The center of the acetabulum and the femoral head were defined, and the distance between these centers was divided by the femoral head diameter, defined as CT migration percentage (CTMP, %). In 123 (82%) of the 150 hips, the femoral head center was located posteriorly, superiorly, and laterally relative to the acetabular center. Large CTalpha cases tended to show large CTMP. CTalpha and CTMP were significantly larger in the cases with Gross Motor Functional Classification System (GMFCS) level IV/V and spastic quadriplegia, than in the cases with GMFCS level II/III and spastic diplegia. CTbeta showed significant correlation with the acetabular defect on the lateral 3D reconstructed images. Three-dimensional acetabular geometry and migration percentage in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. The extent of acetabular dysplasia and subluxation is more severe in patients with GMFCS level IV/V and spastic quadriplesia. Level 4.

  3. Perceptions of Coach-Athlete Relationship Are More Important to Coaches than Athletes in Predicting Dyadic Coping and Stress Appraisals: An Actor-Partner Independence Mediation Model.

    PubMed

    Nicholls, Adam R; Perry, John L

    2016-01-01

    Most attempts to manage stress involve at least one other person, yet coping studies in sport tend to report an athlete's individual coping strategies. There is a limited understanding of coping involving other people, particularly within sport, despite athletes potentially spending a lot of time with other people, such as their coach. Guided by the systemic-transactional model of stress and coping among couples (Bodenmann, 1995), from relationship psychology, we assessed dyadic coping, perceptions of relationship quality, and primary stress appraisals of challenge and threat among 158 coach-athlete dyads (n = 277 participants). The athletes competed at amateur (n = 123), semi-professional (n = 31), or professional levels (n = 4). Coaches and athletes from the same dyad completed a measure of dyadic coping, coach-athlete relationship, and stress appraisals. We tested an Actor-Partner Interdependence Mediation Model to account for the non-independence of dyadic data. These actor-partner analyses revealed differences between athletes and coaches. Although the actor effects were relatively large compared to partner effects, perceptions of relationship quality demonstrated little impact on athletes. The mediating role of relationship quality was broadly as important as dyadic coping for coaches. These findings provide an insight in to how coach-athlete dyads interact to manage stress and indicate that relationship quality is of particular importance for coaches, but less important for athletes. In order to improve perceptions of relationship quality among coaches and athletes, interventions could be developed to foster positive dyadic coping among both coaches and athletes, which may also impact upon stress appraisals of challenge and threat.

  4. Initial validation of the prekindergarten Classroom Observation Tool and goal setting system for data-based coaching.

    PubMed

    Crawford, April D; Zucker, Tricia A; Williams, Jeffrey M; Bhavsar, Vibhuti; Landry, Susan H

    2013-12-01

    Although coaching is a popular approach for enhancing the quality of Tier 1 instruction, limited research has addressed observational measures specifically designed to focus coaching on evidence-based practices. This study explains the development of the prekindergarten (pre-k) Classroom Observation Tool (COT) designed for use in a data-based coaching model. We examined psychometric characteristics of the COT and explored how coaches and teachers used the COT goal-setting system. The study included 193 coaches working with 3,909 pre-k teachers in a statewide professional development program. Classrooms served 3 and 4 year olds (n = 56,390) enrolled mostly in Title I, Head Start, and other need-based pre-k programs. Coaches used the COT during a 2-hr observation at the beginning of the academic year. Teachers collected progress-monitoring data on children's language, literacy, and math outcomes three times during the year. Results indicated a theoretically supported eight-factor structure of the COT across language, literacy, and math instructional domains. Overall interrater reliability among coaches was good (.75). Although correlations with an established teacher observation measure were small, significant positive relations between COT scores and children's literacy outcomes indicate promising predictive validity. Patterns of goal-setting behaviors indicate teachers and coaches set an average of 43.17 goals during the academic year, and coaches reported that 80.62% of goals were met. Both coaches and teachers reported the COT was a helpful measure for enhancing quality of Tier 1 instruction. Limitations of the current study and implications for research and data-based coaching efforts are discussed. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  5. Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitsuyoshi, Takamasa; Nakamura, Mitsuhiro, E-mail: m_nkmr@kuhp.kyoto-u.ac.jp; Matsuo, Yukinori

    The purpose of this article is to quantitatively evaluate differences in dose distributions calculated using various computed tomography (CT) datasets, dose-calculation algorithms, and prescription methods in stereotactic body radiotherapy (SBRT) for patients with early-stage lung cancer. Data on 29 patients with early-stage lung cancer treated with SBRT were retrospectively analyzed. Averaged CT (Ave-CT) and expiratory CT (Ex-CT) images were reconstructed for each patient using 4-dimensional CT data. Dose distributions were initially calculated using the Ave-CT images and recalculated (in the same monitor units [MUs]) by employing Ex-CT images with the same beam arrangements. The dose-volume parameters, including D{sub 95}, D{submore » 90}, D{sub 50}, and D{sub 2} of the planning target volume (PTV), were compared between the 2 image sets. To explore the influence of dose-calculation algorithms and prescription methods on the differences in dose distributions evident between Ave-CT and Ex-CT images, we calculated dose distributions using the following 3 different algorithms: x-ray Voxel Monte Carlo (XVMC), Acuros XB (AXB), and the anisotropic analytical algorithm (AAA). We also used 2 different dose-prescription methods; the isocenter prescription and the PTV periphery prescription methods. All differences in PTV dose-volume parameters calculated using Ave-CT and Ex-CT data were within 3 percentage points (%pts) employing the isocenter prescription method, and within 1.5%pts using the PTV periphery prescription method, irrespective of which of the 3 algorithms (XVMC, AXB, and AAA) was employed. The frequencies of dose-volume parameters differing by >1%pt when the XVMC and AXB were used were greater than those associated with the use of the AAA, regardless of the dose-prescription method employed. All differences in PTV dose-volume parameters calculated using Ave-CT and Ex-CT data on patients who underwent lung SBRT were within 3%pts, regardless of the dose-calculation algorithm or the dose-prescription method employed.« less

  6. Team Software Process (TSP) Body of Knowledge (BOK)

    DTIC Science & Technology

    2010-07-01

    styles that correspond stereotypical extremes of group control and coordination, as shown in Figure 5. closed, random, open, and synchronous group ...and confirming the resolutions • managing the design change process and coordinating changes with the configuration control board • reporting...members. 123 | CMU/SEI-2010-TR-020 4. Coaching – Obtain a lead coach and the coaches for each team. 5. Conceptual design – Form a working group of

  7. TU-G-BRA-04: Changes in Regional Lung Function Measured by 4D-CT Ventilation Imaging for Thoracic Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakajima, Y; Kadoya, N; Kabus, S

    Purpose: To test the hypothesis: 4D-CT ventilation imaging can show the known effects of radiotherapy on lung function: (1) radiation-induced ventilation reductions, and (2) ventilation increases caused by tumor regression. Methods: Repeat 4D-CT scans (pre-, mid- and/or post-treatment) were acquired prospectively for 11 thoracic cancer patients in an IRB-approved clinical trial. A ventilation image for each time point was created using deformable image registration and the Hounsfield unit (HU)-based or Jacobian-based metric. The 11 patients were divided into two subgroups based on tumor volume reduction using a threshold of 5 cm{sup 3}. To quantify radiation-induced ventilation reduction, six patients whomore » showed a small tumor volume reduction (<5 cm{sup 3}) were analyzed for dose-response relationships. To investigate ventilation increase caused by tumor regression, two of the other five patients were analyzed to compare ventilation changes in the lung lobes affected and unaffected by the tumor. The remaining three patients were excluded because there were no unaffected lobes. Results: Dose-dependent reductions of HU-based ventilation were observed in a majority of the patient-specific dose-response curves and in the population-based dose-response curve, whereas no clear relationship was seen for Jacobian-based ventilation. The post-treatment population-based dose-response curve of HU-based ventilation demonstrated the average ventilation reductions of 20.9±7.0% at 35–40 Gy (equivalent dose in 2-Gy fractions, EQD2), and 40.6±22.9% at 75–80 Gy EQD2. Remarkable ventilation increases in the affected lobes were observed for the two patients who showed an average tumor volume reduction of 37.1 cm{sup 3} and re-opening airways. The mid-treatment increase in HU-based ventilation of patient 3 was 100.4% in the affected lobes, which was considerably greater than 7.8% in the unaffected lobes. Conclusion: This study has demonstrated that 4D-CT ventilation imaging shows the known effects of radiotherapy on lung function: radiation-induced ventilation reduction and ventilation increase caused by tumor regression, providing validation for 4D-CT ventilation imaging. This study was supported in part by a National Lung Cancer Partnership Young Investigator Research grant.« less

  8. Effect of Audio Coaching on Correlation of Abdominal Displacement With Lung Tumor Motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakamura, Mitsuhiro; Narita, Yuichiro; Matsuo, Yukinori

    2009-10-01

    Purpose: To assess the effect of audio coaching on the time-dependent behavior of the correlation between abdominal motion and lung tumor motion and the corresponding lung tumor position mismatches. Methods and Materials: Six patients who had a lung tumor with a motion range >8 mm were enrolled in the present study. Breathing-synchronized fluoroscopy was performed initially without audio coaching, followed by fluoroscopy with recorded audio coaching for multiple days. Two different measurements, anteroposterior abdominal displacement using the real-time positioning management system and superoinferior (SI) lung tumor motion by X-ray fluoroscopy, were performed simultaneously. Their sequential images were recorded using onemore » display system. The lung tumor position was automatically detected with a template matching technique. The relationship between the abdominal and lung tumor motion was analyzed with and without audio coaching. Results: The mean SI tumor displacement was 10.4 mm without audio coaching and increased to 23.0 mm with audio coaching (p < .01). The correlation coefficients ranged from 0.89 to 0.97 with free breathing. Applying audio coaching, the correlation coefficients improved significantly (range, 0.93-0.99; p < .01), and the SI lung tumor position mismatches became larger in 75% of all sessions. Conclusion: Audio coaching served to increase the degree of correlation and make it more reproducible. In addition, the phase shifts between tumor motion and abdominal displacement were improved; however, all patients breathed more deeply, and the SI lung tumor position mismatches became slightly larger with audio coaching than without audio coaching.« less

  9. Three-dimensional assessment of curvature, torsion, and canal flare index of the humerus of skeletally mature nonchondrodystrophic dogs.

    PubMed

    Smith, Emily J; Marcellin-Little, Denis J; Harrysson, Ola L A; Griffith, Emily H

    2017-10-01

    OBJECTIVE To assess 3-D geometry of the humerus of dogs and determine whether the craniocaudal canal flare index (CFI) is associated with specific geometric features. SAMPLE CT images (n = 40) and radiographs (38) for 2 groups of skeletally mature nonchondrodystrophic dogs. PROCEDURES General dimensions (length, CFI, cortical thickness, and humeral head offset), curvature (shaft, humeral head, and glenoid cavity), version (humeral head and greater tubercle), and torsion were evaluated on CT images. Dogs were allocated into 3 groups on the basis of the craniocaudal CFI, and results were compared among these 3 groups. The CT measurements were compared with radiographic measurements obtained for another group of dogs. RESULTS Mean ± SD humeral head version was -75.9 ± 9.6° (range, -100.7° to -59.4°). Mean mechanical lateral distal humeral angle, mechanical caudal proximal humeral angle, and mechanical cranial distal humeral angle were 89.5 ± 3.5°, 50.2 ± 4.5°, and 72.9 ± 7.8°, respectively, and did not differ from corresponding radiographic measurements. Mean humeral curvature was 20.4 ± 4.4° (range, 9.6° to 30.5°). Mean craniocaudal CFI was 1.74 ± 0.18 (range, 1.37 to 2.10). Dogs with a high craniocaudal CFI had thicker cranial and medial cortices than dogs with a low craniocaudal CFI. Increased body weight was associated with a lower craniocaudal CFI. Radiographic and CT measurements of craniocaudal CFI and curvature differed significantly. CONCLUSIONS AND CLINICAL RELEVANCE CT-based 3-D reconstructions allowed the assessment of shaft angulation, torsion, and CFI. Radiographic and CT measurements of shaft curvature and CFI may differ.

  10. Impact of using different four-dimensional computed tomography data sets to design proton treatment plans for distal esophageal cancer.

    PubMed

    Pan, Xiaoning; Zhang, Xiaodong; Li, Yupeng; Mohan, Radhe; Liao, Zhongxing

    2009-02-01

    To study the impact of selecting different data sets from four-dimensional computed tomography (4D CT) imaging during proton treatment planning in patients with distal esophageal cancer. We examined the effects of changes in 4D CT data set and smearing margins in proton treatment planning for 5 patients with distal esophageal cancer whose diaphragms were in the beam path and could move several centimeters during respiration. Planning strategies based on (1) average, (2) inspiration, and (3) expiration CT were evaluated in terms of their coverage on the internal clinic target volume (ICTV) at the prescribed dose. For Strategy 1, increasing the smearing margin caused an increase in the ICTV prescription dose coverage (PDC) at the end-exhalation phase for all patients, whereas the ICTV PDC decreased for some patients at the end-inhalation phase. For Strategy 2, a smearing margin in the range of 1.0 to 3.5 cm caused the ICTV PDC to remain essentially unchanged, regardless of which phase of 4D CT was used for dose calculation, for all patients. For Strategy 3, the ICTV coverage was adequate for 2 of the 5 patients when a smearing margin of less than 1.0 cm was used, but was not adequate for the other 3 patients regardless of the smearing margin. Using the inspiration CT plus a smearing margin can lead to adequate ICTV coverage in treatment plans for patients with distal esophageal tumors surrounded by tissue that is subject to large changes in density during a proton treatment.

  11. Dosimetric evaluation of magnetic resonance-generated synthetic CT for radiation treatment of rectal cancer.

    PubMed

    Wang, Hesheng; Du, Kevin; Qu, Juliet; Chandarana, Hersh; Das, Indra J

    2018-01-01

    The purpose of this study was to assess the dosimetric equivalence of magnetic resonance (MR)-generated synthetic CT (synCT) and simulation CT for treatment planning in radiotherapy of rectal cancer. This study was conducted on eleven patients who underwent whole-body PET/MR and PET/CT examination in a prospective IRB-approved study. For each patient synCT was generated from Dixon MR using a model-based method. Standard treatment planning directives were used to create a four-field box (4F), an oblique four-field (O4F) and a volumetric modulated arc therapy (VMAT) plan on synCT for treatment of rectal cancer. The plans were recalculated on CT with the same monitor units (MUs) as that of synCT. Dose-volume metrics of planning target volume (PTV) and organs at risk (OARs) as well as gamma analysis of dose distributions were evaluated to quantify the difference between synCT and CT plans. All plans were calculated using the analytical anisotropic algorithm (AAA). The VMAT plans on synCT and CT were also calculated using the Acuros XB algorithm for comparison with the AAA calculation. Medians of absolute differences in PTV metrics between synCT and CT plans were 0.2%, 0.2% and 0.3% for 4F, O4F and VMAT respectively. No significant differences were observed in OAR dose metrics including bladder V40Gy, mean dose in bladder, bowel V45Gy and femoral head V30Gy in any techniques. Gamma analysis with 2%/2mm dose difference/distance to agreement criteria showed median passing rates of 99.8% (range: 98.5 to 100%), 99.9% (97.2 to 100%), and 99.9% (99.4 to 100%) for 4F, O4F and VMAT, respectively. Using Acuros XB dose calculation, 2%/2mm gamma analysis generated a passing rate of 99.2% (97.7 to 99.9%) for VMAT plans. SynCT enabled dose calculation equivalent to conventional CT for treatment planning of 3D conformal treatment as well as VMAT of rectal cancer. The dosimetric agreement between synCT and CT calculated doses demonstrated the potential of MR-only treatment planning for rectal cancer using MR generated synCT.

  12. Sci-Thur PM: YIS - 03: Comparing 4D-VMAT, Gated-VMAT and 3D-VMAT in SBRT treatment of lung cancer.

    PubMed

    Chin, E; Loewen, S; Nichol, A; Otto, K

    2012-07-01

    To evaluate the treatment plan qualities of 4D-VMAT, gated-VMAT and 3D-VMAT in the treatment of non-small cell lung cancer (NSCLC) in stereotactic body radiation therapy (SBRT). 4D-VMAT is a motion compensation strategy that aims to exploit relative target and OAR motion to increase OAR sparing over 3D-VMAT without the long treatment times associated with gated-VMAT. The 4D-VMAT algorithm incorporates the entire patient respiratory cycle and 4D-CT in the optimization process. Resulting treatment plans synchronize the delivery of each MLC aperture to a specific phase of the target motion. Using software developed in Matlab™, SBRT treatment plans for 4D-VMAT, gated-VMAT and 3D-VMAT were generated on 3 patients with NSCLC. Tumour motion ranged from 1.4-3.4 cm. The fractionation scheme was 48Gy in 4 fractions with the GTV receiving 100% of the prescribed dose. For gated-VMAT, the treatment window constrained residual tumour motion to 3 mm or less corresponding to duty cycles of 40-60%. In 3D-VMAT, the ITV was generated by merging the GTV from all phases. A b-spline transformation model was used to register the 4D-CT images and DVHs were calculated from total dose accumulated on the max expiration phase. For the majority of OARs, gated-VMAT provided the greatest radiation sparing but significantly extended treatment times (25-35 gantry interruptions/arc). For 3D-VMAT, only 2 patients had clinically acceptable plans that met all the strict dose limits. OAR sparing in 4D-VMAT was comparable to gated-VMAT but with significantly improved delivery efficiency. © 2012 American Association of Physicists in Medicine.

  13. SU-F-J-117: Impact of Motion Artifacts On Image Quality and Accuracy of Tumor Motion Reconstruction in 4D CT-On-Rails and MV-CBCT Scans: A Phantom Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, T; Ma, C

    Purpose: To compare and quantify respiratory motion artifacts in images from free breathing 4D-CT-on-Rails(CTOR) and those from MV-Cone-beam-CT(MVCB) and facilitate respiratory motion guided radiation therapy. Methods: 4D-CTOR: Siemens Somatom CT-on-Rails system with Anzai belt loaded with pressure sensor load cells. 4D scans were performed in helical mode, pitch 0.1, gantry rotation time 0.5s, 1.5mm slice thickness, 120kVp, 400 mAs. Normal and fast breathing (>12rpm) scanning protocols were investigated. Helical scan, AIP(average intensity projection) and MIP(maximum intensity projection) were generated from 4D-CTOR scans with amplitude sorting into 10 phases.MVCB: Siemens Artiste diamond view(1MV)MVCB was performed with 5MU thorax protocol with 60more » second of full rotation.Phantom: Anzai AZ-733V respiratory phantom. The settings were set to normal and resp. modes with repetition rates at 15 rpm and 10 rpm. Surgical clips, acrylic, wooden, rubber and lung density, total six mock-ups were scanned and compared in this study.Signal-to-noise ratio(SNR), contrast-to-noise ratio(CNR) and reconstructed motion volume were compared to different respiratory setups for the mock-ups. Results: Reconstructed motion volume was compared to the real object volume for the six test mock-ups. It shows that free breathing helical in all instances underestimates the object excursions largest to −67.4% and least −6.3%. Under normal breathing settings, MIP can predict very precise motion volume with minimum 0.4% and largest −13.9%. MVCB shows underestimate of the motion volume with −1.11% minimum and −18.0% maximum. With fast breathing, AIP provides bad representation of the object motion; however, the MIP can predict the motion volume with −2.0% to −11.4% underestimate. Conclusion: Respiratory motion guided radiation therapy requires good motion recording. This study shows that regular CTOR helical scans provides bad guidance, 4D CTOR AIP cannot represent the fast breathing pattern, MIP can represent the best motion volume, MVCBCT can only be used for normal breathing with acceptable uncertainties.« less

  14. A coaches' perspective on the contribution of anthropometry, physical performance, and motor coordination in racquet sports.

    PubMed

    Robertson, Kamasha; Pion, Johan; Mostaert, Mireille; Norjali Wazir, Mohd Rozilee Wazir; Kramer, Tamara; Faber, Irene Renate; Vansteenkiste, Pieter; Lenoir, Matthieu

    2018-02-21

    Differences and similarities between table tennis and other racquet sports exist, but are not well documented in the literature, in spite of the relevance for talent identification. In this study we aimed at identifying the key characteristics of table tennis in comparison with tennis and badminton based upon a survey in coaches. A total of 177 licensed coaches from all across the world and with diverse professional backgrounds completed a survey on anthropometric measures, physical performance, and motor coordination skills. On a scale from 1 to 10, coaches indicated to what extent a talent characteristic was important for their sport. MANOVA identified key differences as well as similarities between all three racquet sports and a subsequent discriminant analysis allocated coaches correctly for table tennis, tennis, and badminton 81.01%, 55.6%, and 71.4% respectively. Our results show that table tennis and other racquet sport coaches are well aware of differences between the racquet sports and also the importance and value of testing and assortment of skill components. These findings can assist coaches in future talent orientation and transfer in racquet sports.

  15. SU-E-J-26: A Novel Technique for Markerless Self-Sorted 4D-CBCT Using Patient Motion Modeling: A Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, L; Zhang, Y; Harris, W

    2015-06-15

    Purpose: To develop an automatic markerless 4D-CBCT projection sorting technique by using a patient respiratory motion model extracted from the planning 4D-CT images. Methods: Each phase of onboard 4D-CBCT is considered as a deformation of one phase of the prior planning 4D-CT. The deformation field map (DFM) is represented as a linear combination of three major deformation patterns extracted from the planning 4D-CT using principle component analysis (PCA). The coefficients of the PCA deformation patterns are solved by matching the digitally reconstructed radiograph (DRR) of the deformed volume to the onboard projection acquired. The PCA coefficients are solved for eachmore » single projection, and are used for phase sorting. Projections at the peaks of the Z direction coefficient are sorted as phase 1 and other projections are assigned into 10 phase bins by dividing phases equally between peaks. The 4D digital extended-cardiac-torso (XCAT) phantom was used to evaluate the proposed technique. Three scenarios were simulated, with different tumor motion amplitude (3cm to 2cm), tumor spatial shift (8mm SI), and tumor body motion phase shift (2 phases) from prior to on-board images. Projections were simulated over 180 degree scan-angle for the 4D-XCAT. The percentage of accurately binned projections across entire dataset was calculated to represent the phase sorting accuracy. Results: With a changed tumor motion amplitude from 3cm to 2cm, markerless phase sorting accuracy was 100%. With a tumor phase shift of 2 phases w.r.t. body motion, the phase sorting accuracy was 100%. With a tumor spatial shift of 8mm in SI direction, phase sorting accuracy was 86.1%. Conclusion: The XCAT phantom simulation results demonstrated that it is feasible to use prior knowledge and motion modeling technique to achieve markerless 4D-CBCT phase sorting. National Institutes of Health Grant No. R01-CA184173 Varian Medical System.« less

  16. Use of the FLUKA Monte Carlo code for 3D patient-specific dosimetry on PET-CT and SPECT-CT images*

    PubMed Central

    Botta, F; Mairani, A; Hobbs, R F; Vergara Gil, A; Pacilio, M; Parodi, K; Cremonesi, M; Coca Pérez, M A; Di Dia, A; Ferrari, M; Guerriero, F; Battistoni, G; Pedroli, G; Paganelli, G; Torres Aroche, L A; Sgouros, G

    2014-01-01

    Patient-specific absorbed dose calculation for nuclear medicine therapy is a topic of increasing interest. 3D dosimetry at the voxel level is one of the major improvements for the development of more accurate calculation techniques, as compared to the standard dosimetry at the organ level. This study aims to use the FLUKA Monte Carlo code to perform patient-specific 3D dosimetry through direct Monte Carlo simulation on PET-CT and SPECT-CT images. To this aim, dedicated routines were developed in the FLUKA environment. Two sets of simulations were performed on model and phantom images. Firstly, the correct handling of PET and SPECT images was tested under the assumption of homogeneous water medium by comparing FLUKA results with those obtained with the voxel kernel convolution method and with other Monte Carlo-based tools developed to the same purpose (the EGS-based 3D-RD software and the MCNP5-based MCID). Afterwards, the correct integration of the PET/SPECT and CT information was tested, performing direct simulations on PET/CT images for both homogeneous (water) and non-homogeneous (water with air, lung and bone inserts) phantoms. Comparison was performed with the other Monte Carlo tools performing direct simulation as well. The absorbed dose maps were compared at the voxel level. In the case of homogeneous water, by simulating 108 primary particles a 2% average difference with respect to the kernel convolution method was achieved; such difference was lower than the statistical uncertainty affecting the FLUKA results. The agreement with the other tools was within 3–4%, partially ascribable to the differences among the simulation algorithms. Including the CT-based density map, the average difference was always within 4% irrespective of the medium (water, air, bone), except for a maximum 6% value when comparing FLUKA and 3D-RD in air. The results confirmed that the routines were properly developed, opening the way for the use of FLUKA for patient-specific, image-based dosimetry in nuclear medicine. PMID:24200697

  17. Improving Low-dose Cardiac CT Images based on 3D Sparse Representation

    NASA Astrophysics Data System (ADS)

    Shi, Luyao; Hu, Yining; Chen, Yang; Yin, Xindao; Shu, Huazhong; Luo, Limin; Coatrieux, Jean-Louis

    2016-03-01

    Cardiac computed tomography (CCT) is a reliable and accurate tool for diagnosis of coronary artery diseases and is also frequently used in surgery guidance. Low-dose scans should be considered in order to alleviate the harm to patients caused by X-ray radiation. However, low dose CT (LDCT) images tend to be degraded by quantum noise and streak artifacts. In order to improve the cardiac LDCT image quality, a 3D sparse representation-based processing (3D SR) is proposed by exploiting the sparsity and regularity of 3D anatomical features in CCT. The proposed method was evaluated by a clinical study of 14 patients. The performance of the proposed method was compared to the 2D spares representation-based processing (2D SR) and the state-of-the-art noise reduction algorithm BM4D. The visual assessment, quantitative assessment and qualitative assessment results show that the proposed approach can lead to effective noise/artifact suppression and detail preservation. Compared to the other two tested methods, 3D SR method can obtain results with image quality most close to the reference standard dose CT (SDCT) images.

  18. Reduction of metal artifact in three-dimensional computed tomography (3D CT) with dental impression materials.

    PubMed

    Park, W S; Kim, K D; Shin, H K; Lee, S H

    2007-01-01

    Metal Artifact still remains one of the main drawbacks in craniofacial Three-Dimensional Computed Tomography (3D CT). In this study, we tried to test the efficacy of additional silicone dental impression materials as a "tooth shield" for the reduction of metal artifact caused by metal restorations and orthodontic appliances. 6 phantoms with 4 teeth were prepared for this in vitro study. Orthodontic bracket, bands and amalgam restorations were placed in each tooth to reproduce various intraoral conditions. Standardized silicone shields were fabricated and placed around the teeth. CT image acquisition was performed with and without silicone shields. Maximum value, mean, and standard deviation of Hounsfield Units (HU) were compared with the presence of silicone shields. In every situation, metal artifacts were reduced in quality and quantity when silicone shields are used. Amalgam restoration made most serious metal artifact. Silicone shields made by dental impression material might be effective way to reduce the metal artifact caused by dental restoration and orthodontic appliances. This will help more excellent 3D image from 3D CT in craniofacial area.

  19. Four-dimensional computed tomography-based treatment planning for intensity-modulated radiation therapy and proton therapy for distal esophageal cancer.

    PubMed

    Zhang, Xiaodong; Zhao, Kuai-le; Guerrero, Thomas M; McGuire, Sean E; Yaremko, Brian; Komaki, Ritsuko; Cox, James D; Hui, Zhouguang; Li, Yupeng; Newhauser, Wayne D; Mohan, Radhe; Liao, Zhongxing

    2008-09-01

    To compare three-dimensional (3D) and four-dimensional (4D) computed tomography (CT)-based treatment plans for proton therapy or intensity-modulated radiation therapy (IMRT) for esophageal cancer in terms of doses to the lung, heart, and spinal cord and variations in target coverage and normal tissue sparing. The IMRT and proton plans for 15 patients with distal esophageal cancer were designed from the 3D average CT scans and then recalculated on 10 4D CT data sets. Dosimetric data were compared for tumor coverage and normal tissue sparing. Compared with IMRT, median lung volumes exposed to 5, 10, and 20 Gy and mean lung dose were reduced by 35.6%, 20.5%, 5.8%, and 5.1 Gy for a two-beam proton plan and by 17.4%, 8.4%, 5%, and 2.9 Gy for a three-beam proton plan. The greater lung sparing in the two-beam proton plan was achieved at the expense of less conformity to the target (conformity index [CI], 1.99) and greater irradiation of the heart (heart-V40, 41.8%) compared with the IMRT plan(CI, 1.55, heart-V40, 35.7%) or the three-beam proton plan (CI, 1.46, heart-V40, 27.7%). Target coverage differed by more than 2% between the 3D and 4D plans for patients with substantial diaphragm motion in the three-beam proton and IMRT plans. The difference in spinal cord maximum dose between 3D and 4D plans could exceed 5 Gy for the proton plans partly owing to variations in stomach gas filling. Proton therapy provided significantly better sparing of lung than did IMRT. Diaphragm motion and stomach gas-filling must be considered in evaluating target coverage and cord doses.

  20. Observations of youth football training: How do coaches structure training sessions for player development?

    PubMed

    O'Connor, Donna; Larkin, Paul; Williams, A Mark

    2018-01-01

    We used systematic observation tools to explore the structure (i.e., activity and inactivity) and sequencing (i.e., the types of activities used) of football coaching sessions in Australia following the implementation of a new National Curriculum. Youth soccer coaches (n = 34), coaching within the Skill Acquisition (U11-U13 n = 19) and Game Training (U14-U17 n = 15) phases of the Football Federation Australia National Curriculum participated. Participants were filmed during a regular coaching session, with systematic observation of the session undertaken to provide a detailed analysis of the practice activities and coach behaviours. Findings indicated a session comprised of Playing Form activities (40.9%), Training Form activities (22.3%), inactivity (31%), and transitions between activities (5.8%). Coaches prescribed more Training Form activities (e.g., individual (5.4%) and drills (15.1%)) early in the session and progressed to Playing Form activities (i.e., small-sided games (15.3%) then larger games (24.8%)) later in the session. Most inactivity reflected the players listening to the coach - either in a team huddle (9.9%) or frozen on the spot during an activity (16.5%). In addition, coaches generally spent over 3 min communicating to players prior to explaining and introducing an activity regardless of when in the session the activity was scheduled.

  1. SU-F-J-38: Dose Rates and Preliminary Evaluation of Contouring Similarity Metrics Using 4D Cone Beam CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santoso, A; Song, K; Qin, Y

    Purpose: 4D imaging modalities require detailed characterization for clinical optimization. The On-Board Imager mounted on the linear accelerator was used to investigate dose rates in a tissue mimicking phantom using 4D-CBCT and assess variability of contouring similarity metrics between 4D-CT and 4D-CBCT retrospective reconstructions. Methods: A 125 kVp thoracic protocol was used. A phantom placed on a motion platform simulated a patient’s breathing cycle. An ion chamber was affixed inside the phantom’s tissue mimicking cavities (i.e. bone, lung, and soft tissue). A sinusoidal motion waveform was executed with a five second period and superior-inferior motion. Dose rates were measured atmore » six ion chamber positions. A preliminary workflow for contouring similarity between 4D-CT and 4D-CBCT was established using a single lung SBRT patient’s historical data. Average intensity projection (Ave-IP) and maximum intensity projection (MIP) reconstructions generated offline were compared between the 4D modalities. Similarity metrics included Dice similarity coefficient (DSC), Hausdorff distance, and center of mass (COM) deviation. Two isolated lesions were evaluated in the patient’s scans: one located in the right lower lobe (ITVRLL) and one located in the left lower lobe (ITVLLL). Results: Dose rates ranged from 2.30 (lung) to 5.18 (bone) E-3 cGy/mAs. For fixed acquisition parameters, cumulative dose is inversely proportional to gantry speed. For ITVRLL, DSC were 0.70 and 0.68, Hausdorff distances were 6.11 and 5.69 mm, and COM deviations were 1.24 and 4.77 mm, for Ave-IP and MIP respectively. For ITVLLL, DSC were 0.64 and 0.75, Hausdorff distances were 10.74 and 8.00 mm, and COM deviations were 7.55 and 4.3 mm, for Ave-IP and MIP respectively. Conclusion: While the dosimetric output of 4D-CBCT is low, characterization is necessary to assure clinical optimization. A basic workflow for comparison of simulation and treatment 4D image-based contours was established. This work was partially supported by a Research Scholar Grant (RSG-15-137-01-CCE) from the American Cancer Society.« less

  2. Three Dimensional Imaging of Paraffin Embedded Human Lung Tissue Samples by Micro-Computed Tomography

    PubMed Central

    Scott, Anna E.; Vasilescu, Dragos M.; Seal, Katherine A. D.; Keyes, Samuel D.; Mavrogordato, Mark N.; Hogg, James C.; Sinclair, Ian; Warner, Jane A.; Hackett, Tillie-Louise; Lackie, Peter M.

    2015-01-01

    Background Understanding the three-dimensional (3-D) micro-architecture of lung tissue can provide insights into the pathology of lung disease. Micro computed tomography (µCT) has previously been used to elucidate lung 3D histology and morphometry in fixed samples that have been stained with contrast agents or air inflated and dried. However, non-destructive microstructural 3D imaging of formalin-fixed paraffin embedded (FFPE) tissues would facilitate retrospective analysis of extensive tissue archives of lung FFPE lung samples with linked clinical data. Methods FFPE human lung tissue samples (n = 4) were scanned using a Nikon metrology µCT scanner. Semi-automatic techniques were used to segment the 3D structure of airways and blood vessels. Airspace size (mean linear intercept, Lm) was measured on µCT images and on matched histological sections from the same FFPE samples imaged by light microscopy to validate µCT imaging. Results The µCT imaging protocol provided contrast between tissue and paraffin in FFPE samples (15mm x 7mm). Resolution (voxel size 6.7 µm) in the reconstructed images was sufficient for semi-automatic image segmentation of airways and blood vessels as well as quantitative airspace analysis. The scans were also used to scout for regions of interest, enabling time-efficient preparation of conventional histological sections. The Lm measurements from µCT images were not significantly different to those from matched histological sections. Conclusion We demonstrated how non-destructive imaging of routinely prepared FFPE samples by laboratory µCT can be used to visualize and assess the 3D morphology of the lung including by morphometric analysis. PMID:26030902

  3. Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yu, E-mail: yuzhang@smu.edu.cn, E-mail: qianjinfeng08@gmail.com; Wu, Xiuxiu; Yang, Wei

    2014-11-01

    Purpose: The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior–inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane voxel resolutions. Isotropic resolution is necessary for multiplanar display, but the commonly used interpolation operation blurs images. This paper presents a super-resolution (SR) reconstruction method to enhance 4D-CT resolution. Methods: The authors assume that the low-resolution images of different phases at the same position can be regarded as input “frames” to reconstruct high-resolution images.more » The SR technique is used to recover high-resolution images. Specifically, the Demons deformable registration algorithm is used to estimate the motion field between different “frames.” Then, the projection onto convex sets approach is implemented to reconstruct high-resolution lung images. Results: The performance of the SR algorithm is evaluated using both simulated and real datasets. Their method can generate clearer lung images and enhance image structure compared with cubic spline interpolation and back projection (BP) method. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 40.8% relative to cubic spline interpolation and 10.2% versus BP. Conclusions: A new algorithm has been developed to improve the resolution of 4D-CT. The algorithm outperforms the cubic spline interpolation and BP approaches by producing images with markedly improved structural clarity and greatly reduced artifacts.« less

  4. National Program for Inspection of Non-Federal Dams. Talcott Reservoir Dam, Main Dam (CT 00490), Diversion Dike (CT 00489), Dike No. 2 (CT 01710), Connecticut River Basin, West Hartford, Connecticut. Phase I Inspection Report.

    DTIC Science & Technology

    1981-05-01

    ROAD, WALTHAM, MA. 02254 110 14- MONITORING AGENCY NAME A ADORELSS(If dliffeIo town Cenwumf llaj e.. Is. SECURITY CLASS. (of chit mtovet UNCLASSIFIED ISO...Feet Test Flood Elevation 456.24 Feet I I. D- 2 I - i $ 44 - C3 4.44 IV Z0 II a. -f𔃾 0 o f a f V 0 aI We wo ko IL 2 ft ha- V. a. 4 slo zt -i z 49 0

  5. Five-dimensional motion compensation for respiratory and cardiac motion with cone-beam CT of the thorax region

    NASA Astrophysics Data System (ADS)

    Sauppe, Sebastian; Hahn, Andreas; Brehm, Marcus; Paysan, Pascal; Seghers, Dieter; Kachelrieß, Marc

    2016-03-01

    We propose an adapted method of our previously published five-dimensional (5D) motion compensation (MoCo) algorithm1, developed for micro-CT imaging of small animals, to provide for the first time motion artifact-free 5D cone-beam CT (CBCT) images from a conventional flat detector-based CBCT scan of clinical patients. Image quality of retrospectively respiratory- and cardiac-gated volumes from flat detector CBCT scans is deteriorated by severe sparse projection artifacts. These artifacts further complicate motion estimation, as it is required for MoCo image reconstruction. For high quality 5D CBCT images at the same x-ray dose and the same number of projections as todays 3D CBCT we developed a double MoCo approach based on motion vector fields (MVFs) for respiratory and cardiac motion. In a first step our already published four-dimensional (4D) artifact-specific cyclic motion-compensation (acMoCo) approach is applied to compensate for the respiratory patient motion. With this information a cyclic phase-gated deformable heart registration algorithm is applied to the respiratory motion-compensated 4D CBCT data, thus resulting in cardiac MVFs. We apply these MVFs on double-gated images and thereby respiratory and cardiac motion-compensated 5D CBCT images are obtained. Our 5D MoCo approach processing patient data acquired with the TrueBeam 4D CBCT system (Varian Medical Systems). Our double MoCo approach turned out to be very efficient and removed nearly all streak artifacts due to making use of 100% of the projection data for each reconstructed frame. The 5D MoCo patient data show fine details and no motion blurring, even in regions close to the heart where motion is fastest.

  6. Reactive Strength Index: A Poor Indicator of Reactive Strength?

    PubMed

    Healy, Robin; Kenny, Ian; Harrison, Drew

    2017-11-28

    The primary aim was to assess the relationships between reactive strength measures and associated kinematic and kinetic performance variables achieved during drop jumps. A secondary aim was to highlight issues with the use of reactive strength measures as performance indicators. Twenty eight national and international level sprinters, consisting of fourteen men and women, participated in this cross-sectional analysis. Athletes performed drop jumps from a 0.3 m box onto a force platform with dependent variables contact time (CT), landing time (TLand), push-off time (TPush), flight time (FT), jump height (JH), reactive strength index (RSI, calculated as JH / CT), reactive strength ratio (RSR, calculated as FT / CT) and vertical leg spring stiffness (Kvert) recorded. Pearson's correlation test found very high to near perfect relationships between RSI and RSR (r = 0.91 to 0.97), with mixed relationships found between RSI, RSR and the key performance variables, (Men: r = -0.86 to -0.71 between RSI/RSR and CT, r = 0.80 to 0.92 between RSI/RSR and JH; Women: r = -0.85 to -0.56 between RSR and CT, r = 0.71 between RSI and JH). This study demonstrates that the method of assessing reactive strength (RSI versus RSR) may be influenced by the performance strategies adopted i.e. whether an athlete achieves their best reactive strength scores via low CTs, high JHs or a combination. Coaches are advised to limit the variability in performance strategies by implementing upper and / or lower CT thresholds to accurately compare performances between individuals.

  7. Estimation of motion fields by non-linear registration for local lung motion analysis in 4D CT image data.

    PubMed

    Werner, René; Ehrhardt, Jan; Schmidt-Richberg, Alexander; Heiss, Anabell; Handels, Heinz

    2010-11-01

    Motivated by radiotherapy of lung cancer non- linear registration is applied to estimate 3D motion fields for local lung motion analysis in thoracic 4D CT images. Reliability of analysis results depends on the registration accuracy. Therefore, our study consists of two parts: optimization and evaluation of a non-linear registration scheme for motion field estimation, followed by a registration-based analysis of lung motion patterns. The study is based on 4D CT data of 17 patients. Different distance measures and force terms for thoracic CT registration are implemented and compared: sum of squared differences versus a force term related to Thirion's demons registration; masked versus unmasked force computation. The most accurate approach is applied to local lung motion analysis. Masked Thirion forces outperform the other force terms. The mean target registration error is 1.3 ± 0.2 mm, which is in the order of voxel size. Based on resulting motion fields and inter-patient normalization of inner lung coordinates and breathing depths a non-linear dependency between inner lung position and corresponding strength of motion is identified. The dependency is observed for all patients without or with only small tumors. Quantitative evaluation of the estimated motion fields indicates high spatial registration accuracy. It allows for reliable registration-based local lung motion analysis. The large amount of information encoded in the motion fields makes it possible to draw detailed conclusions, e.g., to identify the dependency of inner lung localization and motion. Our examinations illustrate the potential of registration-based motion analysis.

  8. Reference geometry-based detection of (4D-)CT motion artifacts: a feasibility study

    NASA Astrophysics Data System (ADS)

    Werner, René; Gauer, Tobias

    2015-03-01

    Respiration-correlated computed tomography (4D or 3D+t CT) can be considered as standard of care in radiation therapy treatment planning for lung and liver lesions. The decision about an application of motion management devices and the estimation of patient-specific motion effects on the dose distribution relies on precise motion assessment in the planning 4D CT data { which is impeded in case of CT motion artifacts. The development of image-based/post-processing approaches to reduce motion artifacts would benefit from precise detection and localization of the artifacts. Simple slice-by-slice comparison of intensity values and threshold-based analysis of related metrics suffer from- depending on the threshold- high false-positive or -negative rates. In this work, we propose exploiting prior knowledge about `ideal' (= artifact free) reference geometries to stabilize metric-based artifact detection by transferring (multi-)atlas-based concepts to this specific task. Two variants are introduced and evaluated: (S1) analysis and comparison of warped atlas data obtained by repeated non-linear atlas-to-patient registration with different levels of regularization; (S2) direct analysis of vector field properties (divergence, curl magnitude) of the atlas-to-patient transformation. Feasibility of approaches (S1) and (S2) is evaluated by motion-phantom data and intra-subject experiments (four patients) as well as - adopting a multi-atlas strategy- inter-subject investigations (twelve patients involved). It is demonstrated that especially sorting/double structure artifacts can be precisely detected and localized by (S1). In contrast, (S2) suffers from high false positive rates.

  9. SU-E-J-133: Evaluation of Inter- and Intra-Fractional Pancreas Tumor Residual Motions with Abdominal Compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Y; Shi, F; Tian, Z

    2014-06-01

    Purpose: Abdominal compression (AC) has been widely used to reduce pancreas motion due to respiration for pancreatic cancer patients undergoing stereotactic body radiotherapy (SBRT). However, the inter-fractional and intra-fractional patient motions may degrade the treatment. The purpose of this work is to study daily CBCT projections and 4DCT to evaluate the inter-fractional and intra-fractional pancreatic motions. Methods: As a standard of care at our institution, 4D CT scan was performed for treatment planning. At least two CBCT scans were performed for daily treatment. Retrospective studies were performed on patients with implanted internal fiducial markers or surgical clips. The initial motionmore » pattern was obtained by extracting marker positions on every phase of 4D CT images. Daily motions were presented by marker positions on CBCT scan projection images. An adaptive threshold segmentation algorithm was used to extract maker positions. Both marker average positions and motion ranges were compared among three sets of scans, 4D CT, positioning CBCT, and conformal CBCT, for inter-fractional and intra-fractional motion variations. Results: Data from four pancreatic cancer patients were analyzed. These patients had three fiducial markers implanted. All patients were treated by an Elekta Synergy with single fraction SBRT. CBCT projections were acquired by XVI. Markers were successfully detected on most of the projection images. The inter-fractional changes were determined by 4D CT and the first CBCT while the intra-fractional changes were determined by multiple CBCT scans. It is found that the average motion range variations are within 2 mm, however, the average marker positions may drift by 6.5 mm. Conclusion: The patients respiratory motion variation for pancreas SBRT with AC was evaluated by detecting markers from CBCT projections and 4DCT, both the inter-fraction and intra-fraction motion range change is small but the drift of marker positions may be comparable to motion ranges.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devpura, S; Li, H; Liu, C

    Purpose: To correlate dose distributions computed using six algorithms for recurrent early stage non-small cell lung cancer (NSCLC) patients treated with stereotactic body radiotherapy (SBRT), with outcome (local failure). Methods: Of 270 NSCLC patients treated with 12Gyx4, 20 were found to have local recurrence prior to the 2-year time point. These patients were originally planned with 1-D pencil beam (1-D PB) algorithm. 4D imaging was performed to manage tumor motion. Regions of local failures were determined from follow-up PET-CT scans. Follow-up CT images were rigidly fused to the planning CT (pCT), and recurrent tumor volumes (Vrecur) were mapped to themore » pCT. Dose was recomputed, retrospectively, using five algorithms: 3-D PB, collapsed cone convolution (CCC), anisotropic analytical algorithm (AAA), AcurosXB, and Monte Carlo (MC). Tumor control probability (TCP) was computed using the Marsden model (1,2). Patterns of failure were classified as central, in-field, marginal, and distant for Vrecur ≥95% of prescribed dose, 95–80%, 80–20%, and ≤20%, respectively (3). Results: Average PTV D95 (dose covering 95% of the PTV) for 3-D PB, CCC, AAA, AcurosXB, and MC relative to 1-D PB were 95.3±2.1%, 84.1±7.5%, 84.9±5.7%, 86.3±6.0%, and 85.1±7.0%, respectively. TCP values for 1-D PB, 3-D PB, CCC, AAA, AcurosXB, and MC were 98.5±1.2%, 95.7±3.0, 79.6±16.1%, 79.7±16.5%, 81.1±17.5%, and 78.1±20%, respectively. Patterns of local failures were similar for 1-D and 3D PB plans, which predicted that the majority of failures occur in centraldistal regions, with only ∼15% occurring distantly. However, with convolution/superposition and MC type algorithms, the majority of failures (65%) were predicted to be distant, consistent with the literature. Conclusion: Based on MC and convolution/superposition type algorithms, average PTV D95 and TCP were ∼15% lower than the planned 1-D PB dose calculation. Patterns of failure results suggest that MC and convolution/superposition type algorithms predict different outcomes for patterns of failure relative to PB algorithms. Work supported in part by Varian Medical Systems, Palo Alto, CA.« less

  11. Variations of Human DNA Polymerase Genes as Biomarkers of Prostate Cancer Progression

    DTIC Science & Technology

    2011-07-01

    Forward sequence Reverse sequence Sequence contextb 1 g.39835C4Tc P169S 15 25 gTG GGG TC CTT g.39897C4T Intronic 22 15 AGA T GGt TA AAT g.39985T4C...Intronic 34 25 AGA TT tAA AAG g.40051C4Tc P184S 19 34 TGt CT GGA ATT 4 g.39835C4Tc P169S 19 29 gTG GGG TC CTT g.40051C4Tc P184S 23 34 TGt CT GGA ATT 6 g...39835C4Tc P169S 14 24 gTG GGG TC CTT g.40051C4Tc P184S 21 32 TGt CT GGA ATT 11 g.40055A4G D185G 28 35 TTC C AGA C AAG g.40073A4G Y191C 28 20 gGA T AtG CC

  12. Impact of peer delivered wellness coaching.

    PubMed

    Swarbrick, Margaret; Gill, Kenneth J; Pratt, Carlos W

    2016-09-01

    People receiving publicly funded behavioral health services for severe mental disorders have shorter lifespans and significantly impaired health-related quality of life compared to the general population. The aim of this article was to explore how peer wellness coaching (PWC), a manualized approach to pursue specific physical wellness goals, impacted goal attainment and overall health related quality of life. Deidentified archival program evaluation data were examined to explore whether peer delivered wellness coaching had an impact on 33 service recipients with regard to goal attainment and health-related quality of life. Participants were served by 1 of 12 wellness coach trainees from a transformation transfer initiative grant who had been trained in the manualized approach. Coaching participants and their coaches reported significant progress toward the attainment of individually chosen goals, 2 to 4 weeks after establishing their goals. After 8 to 10 weeks of peer delivered wellness coaching, improvements were evident in the self-report of physical health, general health, and perceived health. These improvements were sustained 90 days later. PWC is potentially a promising practice for helping people choose and pursue individual goals and facilitating positive health and wellness changes. Rigorous controlled research with larger samples is needed to evaluate the benefits of peer delivered wellness coaching. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  13. The impact of coaches providing healthy snacks at junior sport training.

    PubMed

    Belski, Regina; Staley, Kiera; Keenan, Stephen; Skiadopoulos, Anne; Randle, Erica; Donaldson, Alex; O'Halloran, Paul; Kappelides, Pam; O'Neil, Stacey; Nicholson, Matthew

    2017-12-01

    Sports clubs provide an opportunity to tackle childhood obesity rates through targeted interventions. Our study aimed to investigate if coaches providing healthy snacks to participants before junior netball sessions at five clubs in Melbourne, Australia, increased consumption of healthy foods and influenced coach perceptions of participants' attention/participation levels. Coaches provided healthy snacks to participants before each netball session for one school term. Children's food consumption was observed at one session before, during and after the intervention. Parents attending the observed session completed pre- and post-intervention questionnaires. Coaches rated participants' attention/participation at the observed sessions before and during the intervention, and completed a questionnaire post-intervention. Baseline: Ice cream and cake were the most frequently consumed snacks. During intervention: Fruit, cheese and crackers and vegetables were the most frequently consumed snacks. Coaches ratings of participants' attention/participation increased significantly (baseline: 6.4 ± 0.17, intervention: 7.5 ± 0.36; p=0.02) where the same coach undertook ratings at both time points. Coaches providing healthy snacks before sessions at sports clubs increased consumption of nutrient-dense foods at the session, and may have positively affected participants' attention/participation. Implications for public health: This study highlights how a simple intervention could improve the diet of Australian children. © 2017 The Authors.

  14. Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy.

    PubMed

    Paradis, Eric; Cao, Yue; Lawrence, Theodore S; Tsien, Christina; Feng, Mary; Vineberg, Karen; Balter, James M

    2015-12-01

    The purpose of this study was to assess the dosimetric accuracy of synthetic CT (MRCT) volumes generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy. A study was conducted in 12 patients with gliomas who underwent both MR and CT imaging as part of their simulation for external beam treatment planning. MRCT volumes were generated from MR images. Patients' clinical treatment planning directives were used to create 12 individual volumetric modulated arc therapy (VMAT) plans, which were then optimized 10 times on each of their respective CT and MRCT-derived electron density maps. Dose metrics derived from optimization criteria, as well as monitor units and gamma analyses, were evaluated to quantify differences between the imaging modalities. Mean differences between planning target volume (PTV) doses on MRCT and CT plans across all patients were 0.0% (range: -0.1 to 0.2%) for D(95%); 0.0% (-0.7 to 0.6%) for D(5%); and -0.2% (-1.0 to 0.2%) for D(max). MRCT plans showed no significant changes in monitor units (-0.4%) compared to CT plans. Organs at risk (OARs) had average D(max) differences of 0.0 Gy (-2.2 to 1.9 Gy) over 85 structures across all 12 patients, with no significant differences when calculated doses approached planning constraints. Focal brain VMAT plans optimized on MRCT images show excellent dosimetric agreement with standard CT-optimized plans. PTVs show equivalent coverage, and OARs do not show any overdose. These results indicate that MRI-derived synthetic CT volumes can be used to support treatment planning of most patients treated for intracranial lesions. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paradis, Eric, E-mail: eparadis@umich.edu; Cao, Yue; Department of Radiology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan

    2015-12-01

    Purpose: The purpose of this study was to assess the dosimetric accuracy of synthetic CT (MRCT) volumes generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy. Methods and Materials: A study was conducted in 12 patients with gliomas who underwent both MR and CT imaging as part of their simulation for external beam treatment planning. MRCT volumes were generated from MR images. Patients' clinical treatment planning directives were used to create 12 individual volumetric modulated arc therapy (VMAT) plans, which were then optimized 10 times on each of their respective CT and MRCT-derived electron density maps. Dosemore » metrics derived from optimization criteria, as well as monitor units and gamma analyses, were evaluated to quantify differences between the imaging modalities. Results: Mean differences between planning target volume (PTV) doses on MRCT and CT plans across all patients were 0.0% (range: −0.1 to 0.2%) for D{sub 95%}; 0.0% (−0.7 to 0.6%) for D{sub 5%}; and −0.2% (−1.0 to 0.2%) for D{sub max}. MRCT plans showed no significant changes in monitor units (−0.4%) compared to CT plans. Organs at risk (OARs) had average D{sub max} differences of 0.0 Gy (−2.2 to 1.9 Gy) over 85 structures across all 12 patients, with no significant differences when calculated doses approached planning constraints. Conclusions: Focal brain VMAT plans optimized on MRCT images show excellent dosimetric agreement with standard CT-optimized plans. PTVs show equivalent coverage, and OARs do not show any overdose. These results indicate that MRI-derived synthetic CT volumes can be used to support treatment planning of most patients treated for intracranial lesions.« less

  16. Dynamic simulation of motion effects in IMAT lung SBRT.

    PubMed

    Zou, Wei; Yin, Lingshu; Shen, Jiajian; Corradetti, Michael N; Kirk, Maura; Munbodh, Reshma; Fang, Penny; Jabbour, Salma K; Simone, Charles B; Yue, Ning J; Rengan, Ramesh; Teo, Boon-Keng Kevin

    2014-11-01

    Intensity modulated arc therapy (IMAT) has been widely adopted for Stereotactic Body Radiotherapy (SBRT) for lung cancer. While treatment dose is optimized and calculated on a static Computed Tomography (CT) image, the effect of the interplay between the target and linac multi-leaf collimator (MLC) motion is not well described and may result in deviations between delivered and planned dose. In this study, we investigated the dosimetric consequences of the inter-play effect on target and organs at risk (OAR) by simulating dynamic dose delivery using dynamic CT datasets. Fifteen stage I non-small cell lung cancer (NSCLC) patients with greater than 10 mm tumor motion treated with SBRT in 4 fractions to a dose of 50 Gy were retrospectively analyzed for this study. Each IMAT plan was initially optimized using two arcs. Simulated dynamic delivery was performed by associating the MLC leaf position, gantry angle and delivered beam monitor units (MUs) for each control point with different respiratory phases of the 4D-CT using machine delivery log files containing time stamps of the control points. Dose maps associated with each phase of the 4D-CT dose were calculated in the treatment planning system and accumulated using deformable image registration onto the exhale phase of the 4D-CT. The original IMAT plans were recalculated on the exhale phase of the CT for comparison with the dynamic simulation. The dose coverage of the PTV showed negligible variation between the static and dynamic simulation. There was less than 1.5% difference in PTV V95% and V90%. The average inter-fraction and cumulative dosimetric effects among all the patients were less than 0.5% for PTV V95% and V90% coverage and 0.8 Gy for the OARs. However, in patients where target is close to the organs, large variations were observed on great vessels and bronchus for as much as 4.9 Gy and 7.8 Gy. Limited variation in target dose coverage and OAR constraints were seen for each SBRT fraction as well as over all four fractions. Large dose variations were observed on critical organs in patients where these organs were closer to the target.

  17. Evaluation of the Elekta Symmetry ™ 4D IGRT system by using a moving lung phantom

    NASA Astrophysics Data System (ADS)

    Shin, Hun-Joo; Kim, Shin-Wook; Kay, Chul Seung; Seo, Jae-Hyuk; Lee, Gi-Woong; Kang, Ki-Mun; Jang, Hong Seok; Kang, Young-nam

    2015-07-01

    Purpose: 4D cone-beam computed tomography (CBCT) is a beneficial tool for the treatment of movable tumors because it can help us to understand where the tumors are actually located and it has a precise treatment plan. However, general CBCT images have a limitation in that they cannot perfectly perform a sophisticated registration. On the other hand, the Symmetry TM 4D image-guided radiation therapy (IGRT) system of Elekta offers a 4D CBCT registration option. In this study, we evaluated the usefulness of Symmetry TM . Method and Materials: Planning CT images of the CIRS moving lung phantom were acquired 4D multi-detector CT (MDCT), and the images were sorted as 10 phases from 0% phase to 90% phase. The thickness of the CT images was 1 mm. Acquired MDCT images were transferred to the contouring software, and a virtual target was generated. A one-arc volumetric-modulated arc therapy (VMAT) plan was performed by using the treatment planning system on the virtual target. Finally, the movement of the phantom was verified by using the XVI Symmetry TM system. Results: The physical movement of the CIRS moving lung phantom was ±10.0 mm in the superiorinferior direction, ±1.0 mm in the lateral direction, and ±2.5 mm in the anterior-posterior direction. The movement of the phantom was measured from the 4D MDCT registration as ±10.2 mm in the superior-inferior direction, ±0.9 mm in the lateral direction, and ±2.45 mm in the anterior-posterior direction. The movement of the phantom was measured from the SymmetryTM registration as ±10.1 mm in the superior-inferior direction, ±0.9 mm in the lateral direction, and ±2.4 mm in the anterior-posterior direction. Conclusion: We confirmed that 4D CBCT is a beneficial tool for the treatment of movable tumors, and that the 4D registration of SymmetryTM can increase the precision of the registration when a movable tumor is the target of radiation treatment.

  18. Implementation of concussion legislation and extent of concussion education for athletes, parents, and coaches in Washington State.

    PubMed

    Chrisman, Sara P; Schiff, Melissa A; Chung, Shana K; Herring, Stanley A; Rivara, Frederick P

    2014-05-01

    Most states in the United States have passed laws regarding concussions, but little is known regarding the implementation of these laws. Hypothesis/ The purpose of this study was to survey high school coaches 3 years after the passage of a concussion law to evaluate the variation in concussion education and knowledge in the context of this law as well as measure the effects of sport (football vs soccer) and urban versus rural locations. The hypothesis was that concussion education and knowledge would be more extensive in football compared with soccer and in urban locations compared with rural locations. Descriptive epidemiology study. A mixed-methods (paper and online) survey was conducted in 2012 to 2013 on a random sample of public high school football, girls' soccer, and boys' soccer coaches in Washington State, stratified by urban and rural locality. The survey covered the extent of concussion education for coaches, athletes, and parents as well as coaches' concussion knowledge and experience. Of 496 coaches contacted, 270 responded (54.4%). Nearly all coaches answered concussion knowledge questions correctly, and nearly all coaches received education via ≥2 modalities (written, video, slide presentation, test, and in person). Athlete education was less extensive, with 34.7% exposed to ≥2 modalities and 29.5% only signing a concussion information form. Parent education was even more limited, with 16.2% exposed to ≥2 modalities and 57.9% only signing a concussion information form. Significantly more football than soccer coaches gave their athletes an in-person talk about concussions (59.1% vs. 39.4%, respectively; P = .002) and provided concussion education to athletes via ≥2 modalities (44.1% vs. 29.7%, respectively; P = .02). Concussion education for coaches and parents was similar between sports, and concussion education for all parties was similar in urban and rural localities. Three years after the passage of a concussion law in Washington State, high school football and soccer coaches are receiving substantial concussion education and have good concussion knowledge. Concussion education for athletes and parents is more limited. Football players receive more extensive concussion education than do soccer players. Clinicians should be aware that athletes and parents may not be receiving significant concussion education.

  19. 68 Ga-PSMA-PET/CT for the evaluation of pulmonary metastases and opacities in patients with prostate cancer.

    PubMed

    Damjanovic, Jonathan; Janssen, Jan-Carlo; Furth, Christian; Diederichs, Gerd; Walter, Thula; Amthauer, Holger; Makowski, Marcus R

    2018-05-16

    The purpose of this study was to investigate the imaging properties of pulmonary metastases and benign opacities in 68 Ga-PSMA positron emission tomography (PET) in patients with prostate cancer (PC). 68 Ga-PSMA-PET/CT scans of 739 PC patients available in our database were evaluated retrospectively for lung metastases and non-solid focal pulmonary opacities. Maximum standardized uptake values (SUV max ) were assessed by two- and three-dimensional regions of interest (2D/3D ROI). Additionally CT features of the lesions, such as location, morphology and size were identified. Ninety-one pulmonary metastases and fourteen opacities were identified in 34 PC patients. In total, 66 PSMA-positive (72.5%) and 25 PSMA-negative (27.5%) metastases were identified. The mean SUV max of pulmonary opacities was 2.2±0.7 in 2D ROI and 2.4±0.8 in 3D ROI. The mean SUV max of PSMA-positive pulmonary metastases was 4.5±2.7 in 2D ROI and in 4.7±2.9 in 3D ROI; this was significantly higher than the SUV max of pulmonary opacities in both 2D and 3D ROI (p<0.001). The mean SUV max of PSMA-negative metastases was 1.0±0.5 in 2D ROI and 1.0±0.4 in 3D ROI, and significantly lower than that of the pulmonary opacities (p<0.001). A significant (p<0.05) weak linear correlation between size and 3D SUV max in lung metastases (ρ Spearman =0.207) was found. Based on the SUV max in 68 Ga-PSMA-PET alone, it was not possible to differentiate between pulmonary metastases and pulmonary opacities. The majority of lung metastases highly overexpressed PSMA, while a relevant number of metastases were PSMA-negative. Pulmonary opacities demonstrated a moderate tracer uptake, significantly lower than PSMA-positive lung metastases, yet significantly higher than PSMA-negative metastases.

  20. Design and implementation of a 3D-MR/CT geometric image distortion phantom/analysis system for stereotactic radiosurgery.

    PubMed

    Damyanovich, A Z; Rieker, M; Zhang, B; Bissonnette, J-P; Jaffray, D A

    2018-03-27

    The design, construction and application of a multimodality, 3D magnetic resonance/computed tomography (MR/CT) image distortion phantom and analysis system for stereotactic radiosurgery (SRS) is presented. The phantom is characterized by (1) a 1 × 1 × 1 (cm) 3 MRI/CT-visible 3D-Cartesian grid; (2) 2002 grid vertices that are 3D-intersections of MR-/CT-visible 'lines' in all three orthogonal planes; (3) a 3D-grid that is MR-signal positive/CT-signal negative; (4) a vertex distribution sufficiently 'dense' to characterize geometrical parameters properly, and (5) a grid/vertex resolution consistent with SRS localization accuracy. When positioned correctly, successive 3D-vertex planes along any orthogonal axis of the phantom appear as 1 × 1 (cm) 2 -2D grids, whereas between vertex planes, images are defined by 1 × 1 (cm) 2 -2D arrays of signal points. Image distortion is evaluated using a centroid algorithm that automatically identifies the center of each 3D-intersection and then calculates the deviations dx, dy, dz and dr for each vertex point; the results are presented as a color-coded 2D or 3D distribution of deviations. The phantom components and 3D-grid are machined to sub-millimeter accuracy, making the device uniquely suited to SRS applications; as such, we present it here in a form adapted for use with a Leksell stereotactic frame. Imaging reproducibility was assessed via repeated phantom imaging across ten back-to-back scans; 80%-90% of the differences in vertex deviations dx, dy, dz and dr between successive 3 T MRI scans were found to be  ⩽0.05 mm for both axial and coronal acquisitions, and over  >95% of the differences were observed to be  ⩽0.05 mm for repeated CT scans, clearly demonstrating excellent reproducibility. Applications of the 3D-phantom/analysis system are presented, using a 32-month time-course assessment of image distortion/gradient stability and statistical control chart for 1.5 T and 3 T GE TwinSpeed MRI systems.

  1. Design and implementation of a 3D-MR/CT geometric image distortion phantom/analysis system for stereotactic radiosurgery

    NASA Astrophysics Data System (ADS)

    Damyanovich, A. Z.; Rieker, M.; Zhang, B.; Bissonnette, J.-P.; Jaffray, D. A.

    2018-04-01

    The design, construction and application of a multimodality, 3D magnetic resonance/computed tomography (MR/CT) image distortion phantom and analysis system for stereotactic radiosurgery (SRS) is presented. The phantom is characterized by (1) a 1 × 1 × 1 (cm)3 MRI/CT-visible 3D-Cartesian grid; (2) 2002 grid vertices that are 3D-intersections of MR-/CT-visible ‘lines’ in all three orthogonal planes; (3) a 3D-grid that is MR-signal positive/CT-signal negative; (4) a vertex distribution sufficiently ‘dense’ to characterize geometrical parameters properly, and (5) a grid/vertex resolution consistent with SRS localization accuracy. When positioned correctly, successive 3D-vertex planes along any orthogonal axis of the phantom appear as 1 × 1 (cm)2-2D grids, whereas between vertex planes, images are defined by 1 × 1 (cm)2-2D arrays of signal points. Image distortion is evaluated using a centroid algorithm that automatically identifies the center of each 3D-intersection and then calculates the deviations dx, dy, dz and dr for each vertex point; the results are presented as a color-coded 2D or 3D distribution of deviations. The phantom components and 3D-grid are machined to sub-millimeter accuracy, making the device uniquely suited to SRS applications; as such, we present it here in a form adapted for use with a Leksell stereotactic frame. Imaging reproducibility was assessed via repeated phantom imaging across ten back-to-back scans; 80%–90% of the differences in vertex deviations dx, dy, dz and dr between successive 3 T MRI scans were found to be  ⩽0.05 mm for both axial and coronal acquisitions, and over  >95% of the differences were observed to be  ⩽0.05 mm for repeated CT scans, clearly demonstrating excellent reproducibility. Applications of the 3D-phantom/analysis system are presented, using a 32-month time-course assessment of image distortion/gradient stability and statistical control chart for 1.5 T and 3 T GE TwinSpeed MRI systems.

  2. SU-G-TeP1-06: Fast GPU Framework for Four-Dimensional Monte Carlo in Adaptive Intensity Modulated Proton Therapy (IMPT) for Mobile Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Botas, P; Heidelberg University, Heidelberg; Grassberger, C

    Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) treatment planning and verification using four-dimensional CT (4DCT) for adaptive IMPT for lung cancer patients. Methods: A validated GPU MC code, gPMC, has been linked to the patient database at our institution and employed to compute the dose-influence matrices (Dij) on the planning CT (pCT). The pCT is an average of the respiratory motion of the patient. The Dijs and patient structures were fed to the optimizer to calculate a treatment plan. To validate the plan against motion, a 4D dose distribution averaged over the possible starting phases is calculatedmore » using the 4DCT and a model of the time structure of the delivered spot map. The dose is accumulated using vector maps created by a GPU-accelerated deformable image registration program (DIR) from each phase of the 4DCT to the reference phase using the B-spline method. Calculation of the Dij matrices and the DIR are performed on a cluster, with each field and vector map calculated in parallel. Results: The Dij production takes ∼3.5s per beamlet for 10e6 protons, depending on the energy and the CT size. Generating a plan with 4D simulation of 1000 spots in 4 fields takes approximately 1h. To test the framework, IMPT plans for 10 lung cancer patients were generated for validation. Differences between the planned and the delivered dose of 19% in dose to some organs at risk and 1.4/21.1% in target mean dose/homogeneity with respect to the plan were observed, suggesting potential for improvement if adaptation is considered. Conclusion: A fast MC treatment planning framework has been developed that allows reliable plan design and verification for mobile targets and adaptation of treatment plans. This will significantly impact treatments for lung tumors, as 4D-MC dose calculations can now become part of planning strategies.« less

  3. Morphometric analysis of the femur in cerebral palsy: 3-dimensional CT study.

    PubMed

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2010-09-01

    The cause of hip disorder in cerebral palsy (CP) has been thought to involve muscle imbalance, flexion, and adduction contracture of the hip joint, acetabular dysplasia, and femoral growth abnormalities. The aim of this study was to quantitatively evaluate the 3-dimensional femoral geometry and subluxation/dislocation of the hip in spastic CP using 3D-CT reconstructed images of the pelvis and the femur, focusing on the femoral growth abnormalities in CP. Between June 2006 and September 2009, 186 hips in 93 bilateral spastic CP patients, including spastic diplegia (SD) in 73 patients and spastic quadriplegia (SQ) in 20 patients, who had not received any surgical treatment, were investigated using 3D-CT at our hospital. There were 59 boys and 34 girls with an average age of 5.3 years (range: 2.6 to 6.8 y). As an index for the femoral geometry, the neck-shaft angle, the femoral anteversion, and the femoral offset were 3-dimensionally measured. The center of the acetabulum and the femoral head were determined to calculate the CT migration percentage as the distance between these centers divided by the femoral head diameter. To elucidate the factors related to hip subluxation/dislocation, the relationships between the neck-shaft angle, the femoral anteversion, the femoral offset, and the CT migration percentage were investigated. The mean neck-shaft angle was 150.4+/-9.4 degrees (range: 129.4 to 173.2 degrees). The mean femoral anteversion was 44.4+/-13.6 degrees (range: 5.8 to 84.0 degrees). The mean CT migration percentage was 22.4+/-22.7% (range: 3 to 129%). There was positive correlation between the CT migration percentage and the neck-shaft angle (r=0.49). Hips with large CT migration percentage tended to show coxa valga. There was an inverse correlation between the neck-shaft angle and the femoral offset (r=-0.90), but no correlation between the CT migration percentage and the femoral anteversion (r=0.26), between the femoral offset and the femoral anteversion (r=-0.25), or between the neck-shaft angle and the femoral anteversion (r=0.23). The neck-shaft angle, the femoral anteversion, and the CT migration percentage were significantly larger, and the femoral offset was significantly smaller, in patients with the Gross Motor Functional Classification System (GMFCS) level IV/V (nonwalking children) and SQ type, than in patients with GMFCS level II/III (mostly walking children) and SD type. The 3-dimensional femoral geometry in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. Our data indicate that 3-dimensional evaluation is accurate and useful for analysis of the femur and acetabulum in CP, and that the extent of coxa valga and femoral anteversion is more severe in the patients with GMFCS level IV/V and SQ type. Level IV.

  4. Motion-robust intensity-modulated proton therapy for distal esophageal cancer.

    PubMed

    Yu, Jen; Zhang, Xiaodong; Liao, Li; Li, Heng; Zhu, Ronald; Park, Peter C; Sahoo, Narayan; Gillin, Michael; Li, Yupeng; Chang, Joe Y; Komaki, Ritsuko; Lin, Steven H

    2016-03-01

    To develop methods for evaluation and mitigation of dosimetric impact due to respiratory and diaphragmatic motion during free breathing in treatment of distal esophageal cancers using intensity-modulated proton therapy (IMPT). This was a retrospective study on 11 patients with distal esophageal cancer. For each patient, four-dimensional computed tomography (4D CT) data were acquired, and a nominal dose was calculated on the average phase of the 4D CT. The changes of water equivalent thickness (ΔWET) to cover the treatment volume from the peak of inspiration to the valley of expiration were calculated for a full range of beam angle rotation. Two IMPT plans were calculated: one at beam angles corresponding to small ΔWET and one at beam angles corresponding to large ΔWET. Four patients were selected for the calculation of 4D-robustness-optimized IMPT plans due to large motion-induced dose errors generated in conventional IMPT. To quantitatively evaluate motion-induced dose deviation, the authors calculated the lowest dose received by 95% (D95) of the internal clinical target volume for the nominal dose, the D95 calculated on the maximum inhale and exhale phases of 4D CT DCT0 andDCT50 , the 4D composite dose, and the 4D dynamic dose for a single fraction. The dose deviation increased with the average ΔWET of the implemented beams, ΔWETave. When ΔWETave was less than 5 mm, the dose error was less than 1 cobalt gray equivalent based on DCT0 and DCT50 . The dose deviation determined on the basis of DCT0 and DCT50 was proportionally larger than that determined on the basis of the 4D composite dose. The 4D-robustness-optimized IMPT plans notably reduced the overall dose deviation of multiple fractions and the dose deviation caused by the interplay effect in a single fraction. In IMPT for distal esophageal cancer, ΔWET analysis can be used to select the beam angles that are least affected by respiratory and diaphragmatic motion. To further reduce dose deviation, the 4D-robustness optimization can be implemented for IMPT planning. Calculation of DCT0 and DCT50 is a conservative method to estimate the motion-induced dose errors.

  5. The effect of incentive spirometry on chest expansion and breathing work in patients with chronic obstructive airway diseases: comparison of two methods.

    PubMed

    Ho, S C; Chiang, L L; Cheng, H F; Lin, H C; Sheng, D F; Kuo, H P; Lin, H C

    2000-02-01

    Chronic obstructive airway diseases (COAD), characterized by mucus hypersecretion, lead to exercise intolerance. Incentive spirometry has been used to prevent postoperative pulmonary atelectasis. To compare the efficacy of two incentive spirometers, Coach (volume-oriented) and Triflo (flow-oriented), in the work of breathing in COAD patients, 22 patients were randomized in this study: 12 patients (Triflo-II group) initially used Triflo-II for 10 minutes and then Coach for the same period. In contrast, the Coach group, including 10 patients, started with Coach followed by Triflo-II. After receiving incentive spirometry, lung expansion and work of breathing were assessed. Patients in the Coach group significantly increased chest wall expansion (p = 0.041), as compared with patients using Triflo-II. Similarly, there was also a significantly increased abdominal wall expansion in the Coach group (p = 0.0056), compared with that in the Triflo-II group. The need of accessory muscle assistance for breathing in the Coach group was significantly less than in the Triflo-II group (p = 0.047). It was easier for patients in the Coach group to start a breath (p = 0.0058) than for those in the Triflo-II group. For the entire group, 17 patients (77.3%) preferred Coach to assist their breathing, and only 4 patients (18.2%) favored Triflo-II. COAD patients achieved a larger expansion of the chest and abdomen with a Coach device. Our data provide a good rationale for an outcome study on the use of incentive spirometer in COAD patients.

  6. Comparative evaluation of two-dimensional radiography and three dimensional computed tomography based dose-volume parameters for high-dose-rate intracavitary brachytherapy of cervical cancer: a prospective study.

    PubMed

    Madan, Renu; Pathy, Sushmita; Subramani, Vellaiyan; Sharma, Seema; Mohanti, Bidhu Kalyan; Chander, Subhash; Thulkar, Sanjay; Kumar, Lalit; Dadhwal, Vatsla

    2014-01-01

    Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiotherapy to pelvis at a dose of 50 Gray in 27 fractions followed by HDR ICRT, 21 Grays to point A in 3 sessions, one week apart was planned . All patients underwent 2D-orthogonal and 3D-CT simulation for each session. Treatment plans were generated using 2D-orthogonal images and dose prescription was made at point A. 3D plans were generated using 3D-CT images after delineating target volume and organs at risk. Comparative evaluation of 2D and 3D treatment planning was made for each session in terms of target coverage (dose received by 90%, 95% and 100% of the target volume: D90, D95 and D100 respectively) and doses to bladder and rectum: ICRU-38 bladder and rectum point dose in 2D planning and dose to 0.1cc, 1cc, 2cc, 5cc, and 10cc of bladder and rectum in 3D planning. Mean doses received by 100% and 90% of the target volume were 4.24 ± 0.63 and 4.9 ± 0.56 Gy respectively. Doses received by 0.1cc, 1cc and 2cc volume of bladder were 2.88 ± 0.72, 2.5 ± 0.65 and 2.2 ± 0.57 times more than the ICRU bladder reference point. Similarly, doses received by 0.1cc, 1cc and 2cc of rectum were 1.80 ± 0.5, 1.48 ± 0.41 and 1.35 ± 0.37 times higher than ICRU rectal reference point. Dosimetric comparative evaluation of 2D and 3D CT based treatment planning for the same brachytherapy session demonstrates underestimation of OAR doses and overestimation of target coverage in 2D treatment planning.

  7. Visual search strategies of experienced and nonexperienced swimming coaches.

    PubMed

    Moreno, Francisco J; Saavedra, José M; Sabido, Rafael; Luis, Vicente; Reina, Raúl

    2006-12-01

    The aim of this study consists of the application of an experimental protocol that allows information to be obtained about the visual search strategies elaborated by swimming coaches. 16 swimming coaches participated. The Experienced group (n=8) had 16.1 yr. (SD=8.2) of coaching experience and at least five years of experience in underwater vision. The Nonexperienced group in underwater vision (n= 8) had 4.2 yr. (SD= 4.0) of coaching experience. Participants were tested in a laboratory environment using a video-projected sample of the crawl stroke of an elite swimmer. This work discusses the main areas of the swimmer's body used by coaches to identify and analyse errors in technique from overhead and underwater perspectives. In front-underwater videos, body roll and mid-water were the locations of the display with higher percentages of fixation time. In the side-underwater slow videos, the upper body was the location with higher percentages of visual fixation time and was used to detect the low elbow fault. Side-overhead takes were not the best perspectives to pick up information directly about performance of the arms; coaches attended to the head as a reference for their visual search. The observation and technical analysis of the hands and arms were facilitated by an underwater perspective. Visual fixation on the elbow served as a reference to identify errors in the upper body. The side-underwater perspective may be an adequate way to identify correct knee angles in leg kicking and the alignment of a swimmer's body and leg actions.

  8. NCAA strength and conditioning coach demographics, current practice trends and common injuries of athletes during strength and conditioning sessions.

    PubMed

    Waryasz, Gregory R; Daniels, Alan H; Gil, Joseph A; Suric, Vladimir; Eberson, Craig P

    2016-10-01

    NCAA strength and conditioning coaches are responsible for the day-to-day conditioning and strength training of collegiate athletes. NCAA regulations will likely require all strength and conditioning coaches to have a strength and conditioning certification. NCAA strength and conditioning coaches have varied philosophies on exercise programming based on educational background. The study aims to further evaluate the backgrounds and exercise philosophies of NCAA strength and conditioning coaches. A survey (Survey Monkey®, Palo Alto, CA, USA) was distributed to NCAA strength and conditioning professionals to evaluate their education background, current practice trends, use of specific equipment and footwear, and what injuries occurred during sessions. Of the 208 survey participants, 77.9% were male with an average age of 34.5±9.1 years old. An exercise-related bachelor's degree was held by 80.4% and an exercise-related master's degree by 72.4%. Over 89% had a strength and conditioning certification. Having a master's, bachelor's, or type strength and conditioning certification had no difference in 1-repetition maximal practice with athletes. Lower extremity injuries made up the highest percentage (58.9%) of injuries seen by NCAA Strength and Conditioning Coaches than lumbar spine injuries (16.7%). The five most common injuries reported during workouts were lumbar strain (N.=431, 14.7%), hamstring strain (N.=332, 11.3%), ankle sprain (N.=299, 10.2%), patellar tendonitis (N.=232, 7.9%), and shin splints (N.=226, 7.7%). Collegiate education and certifications have impact on practice patterns of strength and conditioning coaches in the NCAA.

  9. Can enriching emotional intelligence improve medical students' proactivity and adaptability during OB/GYN clerkships?

    PubMed

    Guseh, Stephanie H; Chen, Xiaodong P; Johnson, Natasha R

    2015-12-26

    The purpose of this pilot study was to examine our hypothesis that enriching workplace emotional intelligence through resident coaches could improve third-year medical students' adaptability and proactivity on the Obstetrics and Gynecology clerkship. An observational pilot study was conducted in a teaching hospital. Fourteen 3rd year medical students from two cohorts of clerkships were randomly divided into two groups, and equally assigned to trained resident coaches and untrained resident coaches. Data was collected through onsite naturalistic observation of students' adaptability and proactivity in clinical settings using a checklist with a 4-point Likert scale (1=poor to 4=excellent). Wilcoxon rank-sum test was used to compare the differences between these two groups. A total of 280 data points were collected through onsite observations conducted by investigators. All (n=14) students' adaptability and proactivity performance significantly improved from an average of 3.04 to 3.45 (p=0.014) over 6-week clerkship. Overall, students with trained resident coaches adapted significantly faster and were more proactive in the obstetrics and gynecology clinical setting than the students with untrained coaches (3.31 vs. 3.24, p=0.019). Findings from our pilot study supported our hypothesis that enriching workplace emotional intelligence knowledge through resident coaches was able to help medical students adapt into obstetrics and gynecology clinical settings faster and become more proactive in learning. Clerkship programs can incorporate the concept of a resident coach in their curriculum to help bridge medical students into clinical settings and to help them engage in self-directed learning throughout the rotation.

  10. Can enriching emotional intelligence improve medical students’ proactivity and adaptability during OB/GYN clerkships?

    PubMed Central

    Guseh, Stephanie H.; Chen, Xiaodong P.

    2015-01-01

    Objectives The purpose of this pilot study was to examine our hypothesis that enriching workplace emotional intelligence through resident coaches could improve third-year medical students’ adaptability and proactivity on the Obstetrics and Gynecology clerkship. Methods An observational pilot study was conducted in a teaching hospital. Fourteen 3rd year medical students from two cohorts of clerkships were randomly divided into two groups, and equally assigned to trained resident coaches and untrained resident coaches. Data was collected through onsite naturalistic observation of students’ adaptability and proactivity in clinical settings using a checklist with a 4-point Likert scale (1=poor to 4=excellent). Wilcoxon rank-sum test was used to compare the differences between these two groups. Results A total of 280 data points were collected through onsite observations conducted by investigators. All (n=14) students’ adaptability and proactivity performance significantly improved from an average of 3.04 to 3.45 (p=0.014) over 6-week clerkship. Overall, students with trained resident coaches adapted significantly faster and were more proactive in the obstetrics and gynecology clinical setting than the students with untrained coaches (3.31 vs. 3.24, p=0.019). Conclusions Findings from our pilot study supported our hypothesis that enriching workplace emotional intelligence knowledge through resident coaches was able to help medical students adapt into obstetrics and gynecology clinical settings faster and become more proactive in learning. Clerkship programs can incorporate the concept of a resident coach in their curriculum to help bridge medical students into clinical settings and to help them engage in self-directed learning throughout the rotation. PMID:26708233

  11. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bieniosek, Matthew F.; Lee, Brian J.; Levin, Craig S., E-mail: cslevin@stanford.edu

    Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom withmore » sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed phantoms can be functionally equivalent to commercially available phantoms. They are a viable option for quickly distributing and fabricating low cost, customized phantoms.« less

  12. Energy of charged states in the acetanilide crystal: trapping of charge-transfer states at vacancies as a possible mechanism for optical damage.

    PubMed

    Tsiaousis, D; Munn, R W

    2004-04-15

    Calculations for the acetanilide crystal yield the effective polarizability (16.6 A(3)), local electric field tensor, effective dipole moment (5.41 D), and dipole-dipole energy (-12.8 kJ/mol). Fourier-transform techniques are used to calculate the polarization energy P for a single charge in the perfect crystal (-1.16 eV); the charge-dipole energy W(D) is zero if the crystal carries no bulk dipole moment. Polarization energies for charge-transfer (CT) pairs combine with the Coulomb energy E(C) to give the screened Coulomb energy E(scr); screening is nearly isotropic, with E(scr) approximately E(C)/2.7. For CT pairs W(D) reduces to a term deltaW(D) arising from the interaction of the charge on each ion with the change in dipole moment on the other ion relative to the neutral molecule. The dipole moments calculated by density-functional theory methods with the B3LYP functional at the 6-311++G(**) level are 3.62 D for the neutral molecule, changing to 7.13 D and 4.38 D for the anion and cation, relative to the center of mass. Because of the large change in the anion, deltaW(D) reaches -0.9 eV and modifies the sequence of CT energies markedly from that of E(scr), giving the lowest two CT pairs at -1.98 eV and -1.41 eV. The changes in P and W(D) near a vacancy are calculated; W(D) changes for the individual charges because the vacancy removes a dipole moment and modifies the crystal dielectric response, but deltaW(D) and E(C) do not change. A vacancy yields a positive change DeltaP that scatters a charge or CT pair, but the change DeltaW(D) can be negative and large enough to outweigh DeltaP, yielding traps with depths that can exceed 150 meV for single charges and for CT pairs. Divacancies yield traps with depths nearly equal to the sum of those produced by the separate vacancies and so they can exceed 300 meV. These results are consistent with a mechanism of optical damage in which vacancies trap optically generated CT pairs that recombine and release energy; this can disrupt the lattice around the vacancy, thereby favoring trapping and recombination of CT pairs generated by subsequent photon absorption, leading to further lattice disruption. Revisions to previous calculations on trapping of CT pairs in anthracene are reported. (c) 2004 American Institute of Physics.

  13. [Clinical application of high-pitch excretory phase images during dual-source CT urography with stellar photon detector].

    PubMed

    Sun, Hao; Xue, Hua-dan; Jin, Zheng-yu; Wang, Xuan; Chen, Yu; He, Yong-lan; Zhang, Da-ming; Zhu, Liang; Wang, Yun; Qi, Bing; Xu, Kai; Wang, Ming

    2014-10-01

    To retrospectively evaluate the clinical feasibility of high-pitch excretory phase images during dual-source CT urography with Stellar photon detector. Totally 100 patients received dual-source CT high-pitch urinary excretory phase scanning with Stellar photon detector [80 kV, ref.92 mAs, CARE Dose 4D and CARE kV, pitch of 3.0, filter back projection reconstruction algorithm (FBP)] (group A). Another 100 patients received dual-source CT high-pitch urinary excretory phase scanning with common detector(100 kV, ref.140 mAs, CARE Dose 4D, pitch of 3.0, FBP) (group B). Quantitative measurement of CT value of urinary segments (Hounsfield units), image noise (Hounsfield units), and effective radiation dose (millisievert) were compared using independent-samples t test between two groups. Urinary system subjective opacification scores were compared using Mann-Whitney U test between two groups. There was no significant difference in subjective opacification score of intrarenal collecting system and ureters between two groups (all P>0.05). The group A images yielded significantly higher CT values of all urinary segments (all P<0.01). There was no significant difference in image noise (P>0.05). The effective radiation dose of group A (1.1 mSv) was significantly lower than that of group B (3.79 mSv) (P<0.01). High-pitch low-tube-voltage during excretory phase dual-source CT urography with Stellar photon detector is feasible, with acceptable image noise and lower radiation dose.

  14. Population-based respiratory 4D motion atlas construction and its application for VR simulations of liver punctures

    NASA Astrophysics Data System (ADS)

    Mastmeyer, Andre; Wilms, Matthias; Handels, Heinz

    2018-03-01

    Virtual reality (VR) training simulators of liver needle insertion in the hepatic area of breathing virtual patients often need 4D image data acquisitions as a prerequisite. Here, first a population-based breathing virtual patient 4D atlas is built and second the requirement of a dose-relevant or expensive acquisition of a 4D CT or MRI data set for a new patient can be mitigated by warping the mean atlas motion. The breakthrough contribution of this work is the construction and reuse of population-based, learned 4D motion models.

  15. Subpial Hematoma and Extravasation in the Interhemispheric Fissure with Subarachnoid Hemorrhage

    PubMed Central

    Matsuoka, Go; Abe, Kayoko; Okada, Yoshikazu; Sakai, Shuji

    2015-01-01

    A recent report on computed tomography (CT) findings of contrast extravasation in subarachnoid hemorrhage (SAH) with Sylvian hematoma suggests that the occurrence of the hematoma is secondary to bleeding in the subpial space. Our patient was in his sixties and was admitted to the hospital because of loss of consciousness (Glasgow Coma Scale E4V1M4). SAH was diagnosed in plain head CT, and growing hematomas were observed in the Sylvian and interhemispheric fissures following a subarachnoid hemorrhage. CT angiography (CTA) using a dual-phase scan protocol revealed contrast extravasation in both the fissures in the latter phase, and hematoma in the interhemispheric fissure contained multiple bleeding points. This case indicates that the occurrence of subpial hematoma such as Sylvian hematoma can be a secondary event following subpial bleeding from damaged small vessels elsewhere in the cranium. Instead of four-dimensional (4D) CT, the dual-phase CTA technique may help detect minor extravasations with usual helical CT scanner. PMID:25963159

  16. The diagnostic accuracy of neck ultrasound, 4D-Computed tomographyand sestamibi imaging in parathyroid carcinoma.

    PubMed

    Christakis, Ioannis; Vu, Thinh; Chuang, Hubert H; Fellman, Bryan; Figueroa, Angelica M Silva; Williams, Michelle D; Busaidy, Naifa L; Perrier, Nancy D

    2017-10-01

    Our aim was to investigate the accuracy of available imaging modalities for parathyroid carcinoma (PC) in our institution and to identify which imaging modality, or combination thereof, is optimal in preoperative determination of precise tumor location. All operated PC patients in our institution between 2000 and 2015 that had at least one of the following in-house preoperative scans: neck ultrasonography (US), neck 4D-Computed Tomography (4DCT) and 99mTc Sestamibi SPECT/CT (MIBI). Sensitivity, specificity and accuracy of PC tumor localization were assessed individually and in combination. 20 patients fulfilled the inclusion criteria and were analysed. There were 18 US, 18 CT and 9 MIBI scans. The sensitivity and accuracy for tumor localisation of US was 80% (CI 56-94%) and 73% respectively, of 4DCT was 79% (CI 58-93%) and 82%, and of MIBI was 81% (CI 54-96%) and 78%. The sensitivity and accuracy of the combination of CT and MIBI was 94% (CI 73-100%) and 95% and for the combination of US, CT and MIBI was 100% (CI 72-100%) and 100% respectively. The wash-out of the PC lesions, expressed as a percentage change in Hounsfield Units from the arterial phase to early delayed phase was -9.29% and to the late delayed phase was -16.88% (n=11). The sensitivity of solitary preoperative imaging of PC patients, whether by US, CT or MIBI, is approximately 80%. Combinations of CT with MIBI and US increase the sensitivity to 95% or better. Combined preoperative imaging of patients with clinical possibility of PC is therefore recommended. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Clinical significance of FDG-PET/CT at the postoperative surveillance in the breast cancer patients.

    PubMed

    Jung, Na Young; Yoo, Ie Ryung; Kang, Bong Joo; Kim, Sung Hun; Chae, Byung Joo; Seo, Ye Young

    2016-01-01

    We evaluated the clinical role of [(18)F]-2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT) compared with conventional imaging (CI) to detect locoregional recurrence or distant metastasis during postoperative surveillance of patients with breast cancer. We included 1,819 examinations of 1,161 patients, who underwent FDG-PET/CT and CI, including mammography, breast ultrasound, whole-body bone scintigraphy, and chest radiography for postoperative surveillance. All patients had a history of surgery with or without adjuvant treatment due to more than stage II breast cancer between November 2003 and November 2009. We evaluated the diagnostic performance of CI, FDG-PET/CT, and combined CI and FDG-PET/CT for detecting locoregional recurrence, distant metastasis, and incidental cancer. We also analyzed false-positive and false-negative results in both FDG-PET/CT and CI. Sensitivity, specificity, positive predictive value, and negative predictive value of CI were 75.4, 98.7, 93.4, and 94.3 %. Those of FDG-PET/CT were 97.5, 98.8, 95.4, and 99.4 %. Those of the combined results were 98.6, 98.2, 96.7, and 99.7 %. Sensitivity of FDG-PET/CT was significantly higher than that of CI (P < 0.05). Sensitivity of combined CI and FDG-PET/CT results improved, but they were not significantly different from those of FDG-PET/CT alone (P = 0.43). Seventeen false-positive and nine false-negative cases were detected with FDG-PET/CT, and 19 false-positive and 88 false-negative cases were detected with CI. FDG-PET/CT is considered as an acceptable diagnostic imaging modality for postoperative surveillance of patients with breast cancer.

  18. MRI-Based Computed Tomography Metal Artifact Correction Method for Improving Proton Range Calculation Accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Peter C.; Schreibmann, Eduard; Roper, Justin

    2015-03-15

    Purpose: Computed tomography (CT) artifacts can severely degrade dose calculation accuracy in proton therapy. Prompted by the recently increased popularity of magnetic resonance imaging (MRI) in the radiation therapy clinic, we developed an MRI-based CT artifact correction method for improving the accuracy of proton range calculations. Methods and Materials: The proposed method replaces corrupted CT data by mapping CT Hounsfield units (HU number) from a nearby artifact-free slice, using a coregistered MRI. MRI and CT volumetric images were registered with use of 3-dimensional (3D) deformable image registration (DIR). The registration was fine-tuned on a slice-by-slice basis by using 2D DIR.more » Based on the intensity of paired MRI pixel values and HU from an artifact-free slice, we performed a comprehensive analysis to predict the correct HU for the corrupted region. For a proof-of-concept validation, metal artifacts were simulated on a reference data set. Proton range was calculated using reference, artifactual, and corrected images to quantify the reduction in proton range error. The correction method was applied to 4 unique clinical cases. Results: The correction method resulted in substantial artifact reduction, both quantitatively and qualitatively. On respective simulated brain and head and neck CT images, the mean error was reduced from 495 and 370 HU to 108 and 92 HU after correction. Correspondingly, the absolute mean proton range errors of 2.4 cm and 1.7 cm were reduced to less than 2 mm in both cases. Conclusions: Our MRI-based CT artifact correction method can improve CT image quality and proton range calculation accuracy for patients with severe CT artifacts.« less

  19. An Interprofessional Approach to Reducing the Risk of Falls Through Enhanced Collaborative Practice.

    PubMed

    Eckstrom, Elizabeth; Neal, Margaret B; Cotrell, Vicki; Casey, Colleen M; McKenzie, Glenise; Morgove, Megan W; DeLander, Gary E; Simonson, William; Lasater, Kathie

    2016-08-01

    Falls are the leading cause of accidental deaths in older adults and are a growing public health concern. The American Geriatrics Society (AGS) and British Geriatrics Society (BGS) published guidelines for falls screening and risk reduction, yet few primary care providers report following any guidelines for falls prevention. This article describes a project that engaged an interprofessional teaching team to support interprofessional clinical teams to reduce fall risk in older adults by implementing the AGS/BGS guidelines. Twenty-five interprofessional clinical teams with representatives from medicine, nursing, pharmacy, and social work were recruited from ambulatory, long-term care, hospital, and home health settings for a structured intervention: a 4-hour training workshop plus coaching for implementation for 1 year. The workshop focused on evidence-based strategies to decrease the risk of falls, including screening for falls; assessing gait, balance, orthostatic blood pressure, and other medical conditions; exercise including tai chi; vitamin D supplementation; medication review and reduction; and environmental assessment. Quantitative and qualitative data were collected using chart reviews, coaching plans and field notes, and postintervention structured interviews of participants. Site visits and coaching field notes confirmed uptake of the strategies. Chart reviews showed significant improvement in adoption of all falls prevention strategies except vitamin D supplementation. Long-term care facilities were more likely to address environmental concerns and add tai chi classes, and ambulatory settings were more likely to initiate falls screening. The intervention demonstrated that interprofessional practice change to target falls prevention can be incorporated into primary care and long-term care settings. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  20. SU-G-JeP2-08: Image-Guided Radiation Therapy Using Synthetic CTs in Brain Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, R.G.; Glide-Hurst, C.; Henry Ford Health System, Detroit, MI

    Purpose: Synthetic-CTs(synCTs) are essential for MR-only treatment planning. However, the performance of synCT for IGRT must be carefully assessed. This work evaluated the accuracy of synCT and synCT-generated DRRs and determined their performance for IGRT in brain cancer radiation therapy. Methods: MR-SIM and CT-SIM images were acquired of a novel anthropomorphic phantom and a cohort of 12 patients. SynCTs were generated by combining an ultra-short echo time (UTE) sequence with other MRI datasets using voxel-based weighted summation. For the phantom, DRRs from synCT and CT were compared via bounding box and landmark analysis. Planar (MV/KV) and volumetric (CBCT) IGRT performancemore » were evaluated across several platforms. In patients, retrospective analysis was conducted to register CBCTs (n=34) to synCTs and CTs using automated rigid registration in the treatment planning system using whole brain and local registration techniques. A semi-automatic registration program was developed and validated to rigidly register planar MV/KV images (n=37) to synCT and CT DRRs. Registration reproducibility was assessed and margin differences were characterized using the van Herk formalism. Results: Bounding box and landmark analysis of phantom synCT DRRs were within 1mm of CT DRRs. Absolute 2D/2D registration shift differences ranged from 0.0–0.7mm for phantom DRRs on all treatment platforms and 0.0–0.4mm for volumetric registrations. For patient planar registrations, mean shift differences were 0.4±0.5mm (range: −0.6–1.6mm), 0.0±0.5mm, (range: −0.9–1.2mm), and 0.1±0.3mm (range: −0.7–0.6mm) for the superior-inferior(S-I), left-right(L–R), and anterior-posterior(A-P) axes, respectively. Mean shift differences in volumetric registrations were 0.6±0.4mm (range: −0.2–1.6mm), 0.2±0.4mm (range: −0.3–1.2mm), and 0.2±0.3mm (range: −0.2–1.2mm) for S-I, L–R, and A–P axes, respectively. CT-SIM and synCT derived margins were within 0.3mm. Conclusion: DRRs generated via synCT agreed well with CT-SIM. Planar and volumetric registrations to synCT-derived targets were comparable to CT. This validation is the next step toward clinical implementation of MR-only planning for the brain. The submitting institution has research agreements with Philips Healthcare. Research sponsored by a Henry Ford Health System Internal Mentored Grant.« less

  1. Phone coaching in Dialectical Behavior Therapy: frequency and relationship to client variables.

    PubMed

    Oliveira, Pedro N; Rizvi, Shireen L

    2018-02-22

    Telephone coaching is a treatment mode in Dialectical Behavior Therapy (DBT) that is designed to help clients generalize skills, prevent suicidal behaviors, and repair therapeutic ruptures. To date, phone coaching has received scant empirical investigation. The aims of this study were to (1) describe patterns in frequency of telephone calls and text messaging in DBT and (2) investigate whether demographic factors, baseline severity, suicidal behaviors, and therapeutic alliance are associated with phone and text frequency. Participants were 51 adults (35 treatment completers) with borderline personality disorder (BPD) in a six-month comprehensive DBT treatment program. Phone coaching frequency was documented by therapist weekly session notes. The average number of contacts per month was 2.55 (SD = 4.49). Four of the 35 treatment completers comprised 56% of the contacts. Having a recent history of suicidal behaviors, degree of severity at baseline, or the strength of the therapeutic alliance was not associated with phone coaching use. However, lower income was significantly associated with a higher frequency of phone coaching use. These preliminary results can help clinicians and administrators make informed decisions on how to better provide phone coaching and clarify the degree of effort involved in providing this service to clients with BPD.

  2. Image fusion in craniofacial virtual reality modeling based on CT and 3dMD photogrammetry.

    PubMed

    Xin, Pengfei; Yu, Hongbo; Cheng, Huanchong; Shen, Shunyao; Shen, Steve G F

    2013-09-01

    The aim of this study was to demonstrate the feasibility of building a craniofacial virtual reality model by image fusion of 3-dimensional (3D) CT models and 3 dMD stereophotogrammetric facial surface. A CT scan and stereophotography were performed. The 3D CT models were reconstructed by Materialise Mimics software, and the stereophotogrammetric facial surface was reconstructed by 3 dMD patient software. All 3D CT models were exported as Stereo Lithography file format, and the 3 dMD model was exported as Virtual Reality Modeling Language file format. Image registration and fusion were performed in Mimics software. Genetic algorithm was used for precise image fusion alignment with minimum error. The 3D CT models and the 3 dMD stereophotogrammetric facial surface were finally merged into a single file and displayed using Deep Exploration software. Errors between the CT soft tissue model and 3 dMD facial surface were also analyzed. Virtual model based on CT-3 dMD image fusion clearly showed the photorealistic face and bone structures. Image registration errors in virtual face are mainly located in bilateral cheeks and eyeballs, and the errors are more than 1.5 mm. However, the image fusion of whole point cloud sets of CT and 3 dMD is acceptable with a minimum error that is less than 1 mm. The ease of use and high reliability of CT-3 dMD image fusion allows the 3D virtual head to be an accurate, realistic, and widespread tool, and has a great benefit to virtual face model.

  3. Impact of Using Different Four-Dimensional Computed Tomography Data Sets to Design Proton Treatment Plans for Distal Esophageal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan Xiaoning; Zhang Xiaodong; Li Yupeng

    2009-02-01

    Purpose: To study the impact of selecting different data sets from four-dimensional computed tomography (4D CT) imaging during proton treatment planning in patients with distal esophageal cancer. Methods and Materials: We examined the effects of changes in 4D CT data set and smearing margins in proton treatment planning for 5 patients with distal esophageal cancer whose diaphragms were in the beam path and could move several centimeters during respiration. Planning strategies based on (1) average, (2) inspiration, and (3) expiration CT were evaluated in terms of their coverage on the internal clinic target volume (ICTV) at the prescribed dose. Results:more » For Strategy 1, increasing the smearing margin caused an increase in the ICTV prescription dose coverage (PDC) at the end-exhalation phase for all patients, whereas the ICTV PDC decreased for some patients at the end-inhalation phase. For Strategy 2, a smearing margin in the range of 1.0 to 3.5 cm caused the ICTV PDC to remain essentially unchanged, regardless of which phase of 4D CT was used for dose calculation, for all patients. For Strategy 3, the ICTV coverage was adequate for 2 of the 5 patients when a smearing margin of less than 1.0 cm was used, but was not adequate for the other 3 patients regardless of the smearing margin. Conclusion: Using the inspiration CT plus a smearing margin can lead to adequate ICTV coverage in treatment plans for patients with distal esophageal tumors surrounded by tissue that is subject to large changes in density during a proton treatment.« less

  4. From PBL tutoring to PBL coaching in undergraduate medical education: an interpretative phenomenological analysis study

    PubMed Central

    Wang, Qing; Li, Huiping; Pang, Weiguo

    2016-01-01

    Background Coaching psychology is of increasing interest to medical educators for its potential benefits as a facilitative method in problem-based learning (PBL). However, the field lacks empirical studies that explore the lived experiences of students and tutors in the PBL coaching process. This study aimed to elicit knowledge regarding medical students’ and tutors’ experiences and perceptions of PBL coaching in the context of Chinese undergraduate medical education. Methods The qualitative methodology of interpretative phenomenological analysis (IPA) was employed. Participants comprised third year medical students (n=20) and PBL tutors (n=5) who have adopted a coaching approach in PBL for a semester. Semi-structured interviews were utilized to obtain a comprehensive understanding of their experiences of PBL coaching. Data analysis followed an iterative four-stage scheme of Biggerstaff and Thompson. Results Six main themes emerged from diverse experiences and interpretations: 1) mindsets of coaching and learning, 2) the development of learning dispositions and capacities, 3) student group collaboration, 4) tutor–student relationships, 5) personal and professional development, and 6) challenges and difficulties in implementation. Conclusions It could be concluded that PBL coaching is a dynamic, facilitative process that makes a particular contribution to the learning process from psychological, emotional, and social perspectives, whilst it demonstrates significant overlaps with PBL tutoring in terms of supporting students’ cognitive activities in PBL. Further research is needed to identify the barriers and challenges for medical educators to implement coaching in the PBL process. PMID:27396900

  5. From PBL tutoring to PBL coaching in undergraduate medical education: an interpretative phenomenological analysis study.

    PubMed

    Wang, Qing; Li, Huiping; Pang, Weiguo

    2016-01-01

    Coaching psychology is of increasing interest to medical educators for its potential benefits as a facilitative method in problem-based learning (PBL). However, the field lacks empirical studies that explore the lived experiences of students and tutors in the PBL coaching process. This study aimed to elicit knowledge regarding medical students' and tutors' experiences and perceptions of PBL coaching in the context of Chinese undergraduate medical education. The qualitative methodology of interpretative phenomenological analysis (IPA) was employed. Participants comprised third year medical students (n=20) and PBL tutors (n=5) who have adopted a coaching approach in PBL for a semester. Semi-structured interviews were utilized to obtain a comprehensive understanding of their experiences of PBL coaching. Data analysis followed an iterative four-stage scheme of Biggerstaff and Thompson. Six main themes emerged from diverse experiences and interpretations: 1) mindsets of coaching and learning, 2) the development of learning dispositions and capacities, 3) student group collaboration, 4) tutor-student relationships, 5) personal and professional development, and 6) challenges and difficulties in implementation. It could be concluded that PBL coaching is a dynamic, facilitative process that makes a particular contribution to the learning process from psychological, emotional, and social perspectives, whilst it demonstrates significant overlaps with PBL tutoring in terms of supporting students' cognitive activities in PBL. Further research is needed to identify the barriers and challenges for medical educators to implement coaching in the PBL process.

  6. From PBL tutoring to PBL coaching in undergraduate medical education: an interpretative phenomenological analysis study.

    PubMed

    Wang, Qing; Li, Huiping; Pang, Weiguo

    2016-01-01

    Background Coaching psychology is of increasing interest to medical educators for its potential benefits as a facilitative method in problem-based learning (PBL). However, the field lacks empirical studies that explore the lived experiences of students and tutors in the PBL coaching process. This study aimed to elicit knowledge regarding medical students' and tutors' experiences and perceptions of PBL coaching in the context of Chinese undergraduate medical education. Methods The qualitative methodology of interpretative phenomenological analysis (IPA) was employed. Participants comprised third year medical students (n=20) and PBL tutors (n=5) who have adopted a coaching approach in PBL for a semester. Semi-structured interviews were utilized to obtain a comprehensive understanding of their experiences of PBL coaching. Data analysis followed an iterative four-stage scheme of Biggerstaff and Thompson. Results Six main themes emerged from diverse experiences and interpretations: 1) mindsets of coaching and learning, 2) the development of learning dispositions and capacities, 3) student group collaboration, 4) tutor-student relationships, 5) personal and professional development, and 6) challenges and difficulties in implementation. Conclusions It could be concluded that PBL coaching is a dynamic, facilitative process that makes a particular contribution to the learning process from psychological, emotional, and social perspectives, whilst it demonstrates significant overlaps with PBL tutoring in terms of supporting students' cognitive activities in PBL. Further research is needed to identify the barriers and challenges for medical educators to implement coaching in the PBL process.

  7. Impact of respiratory-correlated CT sorting algorithms on the choice of margin definition for free-breathing lung radiotherapy treatments.

    PubMed

    Thengumpallil, Sheeba; Germond, Jean-François; Bourhis, Jean; Bochud, François; Moeckli, Raphaël

    2016-06-01

    To investigate the impact of Toshiba phase- and amplitude-sorting algorithms on the margin strategies for free-breathing lung radiotherapy treatments in the presence of breathing variations. 4D CT of a sphere inside a dynamic thorax phantom was acquired. The 4D CT was reconstructed according to the phase- and amplitude-sorting algorithms. The phantom was moved by reproducing amplitude, frequency, and a mix of amplitude and frequency variations. Artefact analysis was performed for Mid-Ventilation and ITV-based strategies on the images reconstructed by phase- and amplitude-sorting algorithms. The target volume deviation was assessed by comparing the target volume acquired during irregular motion to the volume acquired during regular motion. The amplitude-sorting algorithm shows reduced artefacts for only amplitude variations while the phase-sorting algorithm for only frequency variations. For amplitude and frequency variations, both algorithms perform similarly. Most of the artefacts are blurring and incomplete structures. We found larger artefacts and volume differences for the Mid-Ventilation with respect to the ITV strategy, resulting in a higher relative difference of the surface distortion value which ranges between maximum 14.6% and minimum 4.1%. The amplitude- is superior to the phase-sorting algorithm in the reduction of motion artefacts for amplitude variations while phase-sorting for frequency variations. A proper choice of 4D CT sorting algorithm is important in order to reduce motion artefacts, especially if Mid-Ventilation strategy is used. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Development and validation of technique for in-vivo 3D analysis of cranial bone graft survival

    NASA Astrophysics Data System (ADS)

    Bernstein, Mark P.; Caldwell, Curtis B.; Antonyshyn, Oleh M.; Ma, Karen; Cooper, Perry W.; Ehrlich, Lisa E.

    1997-05-01

    Bone autografts are routinely employed in the reconstruction of facial deformities resulting from trauma, tumor ablation or congenital malformations. The combined use of post- operative 3D CT and SPECT imaging provides a means for quantitative in vivo evaluation of bone graft volume and osteoblastic activity. The specific objectives of this study were: (1) Determine the reliability and accuracy of interactive computer-assisted analysis of bone graft volumes based on 3D CT scans; (2) Determine the error in CT/SPECT multimodality image registration; (3) Determine the error in SPECT/SPECT image registration; and (4) Determine the reliability and accuracy of CT-guided SPECT uptake measurements in cranial bone grafts. Five human cadaver heads served as anthropomorphic models for all experiments. Four cranial defects were created in each specimen with inlay and onlay split skull bone grafts and reconstructed to skull and malar recipient sites. To acquire all images, each specimen was CT scanned and coated with Technetium doped paint. For purposes of validation, skulls were landmarked with 1/16-inch ball-bearings and Indium. This study provides a new technique relating anatomy and physiology for the analysis of cranial bone graft survival.

  9. Telephone Coaching to Enhance a Home-Based Physical Activity Program for Knee Osteoarthritis: A Randomized Clinical Trial.

    PubMed

    Bennell, Kim L; Campbell, Penny K; Egerton, Thorlene; Metcalf, Ben; Kasza, Jessica; Forbes, Andrew; Bills, Caroline; Gale, Janette; Harris, Anthony; Kolt, Gregory S; Bunker, Stephen J; Hunter, David J; Brand, Caroline A; Hinman, Rana S

    2017-01-01

    To investigate whether simultaneous telephone coaching improves the clinical effectiveness of a physiotherapist-prescribed home-based physical activity program for knee osteoarthritis (OA). A total of 168 inactive adults ages ≥50 years with knee pain on a numeric rating scale ≥4 (NRS; range 0-10) and knee OA were recruited from the community and randomly assigned to a physiotherapy (PT) and coaching group (n = 84) or PT-only (n = 84) group. All participants received five 30-minute consultations with a physiotherapist over 6 months for education, home exercise, and physical activity advice. PT+coaching participants also received 6-12 telephone coaching sessions by clinicians trained in behavioral-change support for exercise and physical activity. Primary outcomes were pain (NRS) and physical function (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC; score range 0-68]) at 6 months. Secondary outcomes were these same measures at 12 and 18 months, as well as physical activity, exercise adherence, other pain and function measures, and quality of life. Analyses were intent-to-treat with multiple imputation for missing data. A total of 142 (85%), 136 (81%), and 128 (76%) participants completed 6-, 12-, and 18-month measurements, respectively. The change in NRS pain (mean difference 0.4 unit [95% confidence interval (95% CI) -0.4, 1.3]) and in WOMAC function (1.8 [95% CI -1.9, 5.5]) did not differ between groups at 6 months, with both groups showing clinically relevant improvements. Some secondary outcomes related to physical activity and exercise behavior favored PT+coaching at 6 months but generally not at 12 or 18 months. There were no between-group differences in most other outcomes. The addition of simultaneous telephone coaching did not augment the pain and function benefits of a physiotherapist-prescribed home-based physical activity program. © 2016, American College of Rheumatology.

  10. Feasibility of using an inversion-recovery ultrashort echo time (UTE) sequence for quantification of glenoid bone loss.

    PubMed

    Ma, Ya-Jun; West, Justin; Nazaran, Amin; Cheng, Xin; Hoenecke, Heinz; Du, Jiang; Chang, Eric Y

    2018-02-02

    To utilize the 3D inversion recovery prepared ultrashort echo time with cones readout (IR-UTE-Cones) MRI technique for direct imaging of lamellar bone with comparison to the gold standard of computed tomography (CT). CT and MRI was performed on 11 shoulder specimens and three patients. Five specimens had imaging performed before and after glenoid fracture (osteotomy). 2D and 3D volume-rendered CT images were reconstructed and conventional T1-weighted and 3D IR-UTE-Cones MRI techniques were performed. Glenoid widths and defects were independently measured by two readers using the circle method. Measurements were compared with those made from 3D CT datasets. Paired-sample Student's t tests and intraclass correlation coefficients were performed. In addition, 2D CT and 3D IR-UTE-Cones MRI datasets were linearly registered, digitally overlaid, and compared in consensus by these two readers. Compared with the reference standard (3D CT), glenoid bone diameter measurements made on 2D CT and 3D IR-UTE-Cones were not significantly different for either reader, whereas T1-weighted images underestimated the diameter (mean difference of 0.18 cm, p = 0.003 and 0.16 cm, p = 0.022 for readers 1 and 2, respectively). However, mean margin of error for measuring glenoid bone loss was small for all modalities (range, 1.46-3.92%). All measured ICCs were near perfect. Digitally registered 2D CT and 3D IR-UTE-Cones MRI datasets yielded essentially perfect congruity between the two modalities. The 3D IR-UTE-Cones MRI technique selectively visualizes lamellar bone, produces similar contrast to 2D CT imaging, and compares favorably to measurements made using 2D and 3D CT.

  11. The Impact of Different Degrees of Feedback on Physical Activity Levels: A 4-Week Intervention Study

    PubMed Central

    Van Hoye, Karen; Boen, Filip; Lefevre, Johan

    2015-01-01

    Assessing levels of physical activity (PA) and providing feedback about these levels might have an effect on participant’s PA behavior. This study discusses the effect of different levels of feedback—from minimal to use of a feedback display and coach—on PA over a 4-week intervention period. PA was measured at baseline, during and immediately after the intervention. Participants (n = 227) were randomly assigned to a Minimal Intervention Group (MIG-no feedback), Pedometer Group (PG-feedback on steps taken), Display Group (DG-feedback on steps, minutes of moderate to vigorous physical activity and energy expenditure) or Coaching Group (CoachG-same as DG with need-supportive coaching). Two-way ANCOVA showed no significant Group × Time interaction effect for the different PA variables between the MIG and PG. Also no differences emerged between PG and DG. As hypothesized, CoachG had higher PA values throughout the intervention compared with DG. Self-monitoring using a pedometer resulted in more steps compared with a no-feedback condition at the start of the intervention. However, adding individualized coaching seems necessary to increase the PA level until the end of the intervention. PMID:26067990

  12. A Preliminary Investigation of a Relapse Prevention Mobile Application to Maintain Smoking Abstinence Among Individuals With Posttraumatic Stress Disorder.

    PubMed

    Hicks, Terrell A; Thomas, Shaun P; Wilson, Sarah M; Calhoun, Patrick S; Kuhn, Eric R; Beckham, Jean C

    2017-01-01

    Smokers with posttraumatic stress disorder (PTSD) have increased difficulty achieving and maintaining abstinence. Contingency management approaches to smoking cessation interventions have demonstrated short-term efficacy but are limited by high rates of relapse. The goal of this pilot study was to evaluate the usability and feasibility of a smartphone-based smoking cessation application (Stay Quit Coach) designed to prevent relapse among individuals with PTSD. Smokers (N = 11) were randomized to (1) QUIT4EVER, an intervention combining mobile contingency management smoking cessation counseling and medications, and Stay Quit Coach or (2) a contact control condition that was identical to QUIT4EVER except Stay Quit Coach was not included. The primary outcome was prolonged smoking abstinence. Among those queried during the follow-up periods, average Stay Quit Coach helpfulness ratings were high and ranged from 7.25 to 10 on a 10-point Likert scale (with higher scores corresponding to greater helpfulness). The Stay Quit Coach was rated by participants as being most effective at helping to quit smoking, helping to remain quit, and providing support and relevant information about quitting. Among the three quitters in the QUIT4EVER group, all reported abstinence at 3 and 6 months; however, abstinence was only bioverified for one quitter at 6 months. Among the four quitters in the contact control condition group, three reported abstinence at 3 and 6 months, but abstinence was not confirmed by bioverification. Smokers with PTSD express interest in and helpfulness of Stay Quit Coach for remaining abstinent after a quit attempt. Combined use of mobile contingency management and Stay Quit Coach is a feasible and acceptable adjunctive smoking cessation treatment for reducing smoking among smokers with PTSD. Adequately powered clinical trials are needed to demonstrate the long-term efficacy of this combined approach to smoking cessation. This study [Use of Technological Advances to Prevent Smoking Relapse among Smokers with PTSD (QUIT4EVER)] was registered on www.clinicaltrials.gov . clinicaltrials.gov identifier: NCT01990079.

  13. Low programmed cell death-1 (PD-1) expression in peripheral CD4(+) T cells in Japanese patients with autoimmune type 1 diabetes.

    PubMed

    Fujisawa, R; Haseda, F; Tsutsumi, C; Hiromine, Y; Noso, S; Kawabata, Y; Mitsui, S; Terasaki, J; Ikegami, H; Imagawa, A; Hanafusa, T

    2015-06-01

    Programmed cell death-1 (PD-1) is a co-stimulatory molecule that inhibits T cell proliferation. We aimed to clarify PD-1 expression in CD4(+) T cells and the association between PD-1 expression and the 7785C/T polymorphism of PDCD1, with a focus on the two subtypes of type 1 diabetes, type 1A diabetes (T1AD) and fulminant type 1 diabetes (FT1D), in the Japanese population. We examined 22 patients with T1AD, 15 with FT1D, 19 with type 2 diabetes (T2D) and 29 healthy control (HC) subjects. Fluorescence-activated cell sorting (FACS) and real-time PCR were utilized to analyse PD-1 expression quantitatively. Genotyping of 7785C/T in PDCD1 was performed using the TaqMan method in a total of 63 subjects (21 with T1AD, 15 with FT1D and 27 HC). FACS revealed a significant reduction in PD-1 expression in CD4(+) T cells in patients with T1AD (mean: 4.2 vs. 6.0% in FT1D, P=0.0450; vs. 5.8% in T2D, P=0.0098; vs. 6.0% in HC, P=0.0018). PD-1 mRNA expression in CD4(+) T cells was also significantly lower in patients with T1AD than in the HC subjects. Of the 63 subjects, PD-1 expression was significantly lower in individuals with the 7785C/C genotype than in those with the C/T and T/T genotypes (mean: 4.1 vs. 5.9%, P=0.0016). Our results indicate that lower PD-1 expression in CD4(+) T-cells might contribute to the development of T1AD through T cell activation. © 2015 British Society for Immunology.

  14. Individualized Physical 3-dimensional Kidney Tumor Models Constructed From 3-dimensional Printers Result in Improved Trainee Anatomic Understanding.

    PubMed

    Knoedler, Margaret; Feibus, Allison H; Lange, Andrew; Maddox, Michael M; Ledet, Elisa; Thomas, Raju; Silberstein, Jonathan L

    2015-06-01

    To evaluate the effect of 3-dimensionally (3D) printed physical renal models with enhancing masses on medical trainee characterization, localization, and understanding of renal malignancy. Proprietary software was used to import standard computed tomography (CT) cross-sectional imaging into 3D printers to create physical models of renal units with enhancing renal lesions in situ. Six different models were printed from a transparent plastic resin; the normal parenchyma was printed in a clear, translucent plastic, with a red hue delineating the suspicious renal lesion. Medical students, who had completed their first year of training, were given an overview and tasked with completion of RENAL nephrometry scores, separately using CT imaging and 3D models. Trainees were also asked to complete a questionnaire about their experience. Variability between trainees was assessed by intraclass correlation coefficients (ICCs), and kappa statistics were used to compare the trainee to experts. Overall trainee nephrometry score accuracy was significantly improved with the 3D model vs CT scan (P <.01). Furthermore, 3 of the 4 components of the nephrometry score (radius, nearness to collecting system, and location) showed significant improvement (P <.001) using the models. There was also more consistent agreement among trainees when using the 3D models compared with CT scans to assess the nephrometry score (intraclass correlation coefficient, 0.28 for CT scan vs 0.72 for 3D models). Qualitative evaluation with questionnaires filled out by the trainees further confirmed that the 3D models improved their ability to understand and conceptualize the renal mass. Physical 3D models using readily available printing techniques improve trainees' understanding and characterization of individual patients' enhancing renal lesions. Published by Elsevier Inc.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, S; Yuen, C; Huang, V

    Purpose: In this abstract we implement and validate a 4D VMAT Acuros XB dose calculation using Gafchromic film. Special attention is paid to the physical material assignment in the CT dataset and to reported dose to water and dose to medium. Methods: A QUASAR phantom with a 3 cm sinusoidal tumor motion and 5 second period was scanned using 4D computed tomography. A CT was also obtained of the static QUASAR phantom with the tumor at the central position. A VMAT plan was created on the average CT dataset and was delivered on a Varian TrueBeam linear accelerator. The trajectorymore » log file from this treatment was acquired and used to create 10 VMAT subplans (one for each portion of the breathing cycle). Motion for each subplan was simulated by moving the beam isocentre in the superior/inferior direction in the Treatment Planning System on the static CT scan. The 10 plans were calculated (both dose to medium and dose to water) and summed for 1) the original HU values from the static CT scan and 2) the correct physical material assignment in the CT dataset. To acquire a breathing phase synchronized film measurements the trajectory log was used to create a VMAT delivery plan which includes dynamic couch motion using the Developer Mode. Three different treatment start phases were investigated (mid inhalation, full inhalation and full exhalation). Results: For each scenario the coronal dose distributions were measured using Gafchromic film and compared to the corresponding calculation with Film QA Pro Software using a Gamma test with a 3%/3mm distance to agreement criteria. Good agreement was found between calculation and measurement. No statistically significant difference in agreement was found between calculations to original HU values vs calculations to over-written (material-assigned) HU values. Conclusion: The investigated 4D dose calculation method agrees well with measurement.« less

  16. Accuracy of Cup Positioning With the Computed Tomography-Based Two-dimensional to Three-Dimensional Matched Navigation System: A Prospective, Randomized Controlled Study.

    PubMed

    Yamada, Kazuki; Endo, Hirosuke; Tetsunaga, Tomonori; Miyake, Takamasa; Sanki, Tomoaki; Ozaki, Toshifumi

    2018-01-01

    The accuracy of various navigation systems used for total hip arthroplasty has been described, but no publications reported the accuracy of cup orientation in computed tomography (CT)-based 2D-3D (two-dimensional to three-dimensional) matched navigation. In a prospective, randomized controlled study, 80 hips including 44 with developmental dysplasia of the hips were divided into a CT-based 2D-3D matched navigation group (2D-3D group) and a paired-point matched navigation group (PPM group). The accuracy of cup orientation (absolute difference between the intraoperative record and the postoperative measurement) was compared between groups. Additionally, multiple logistic regression analysis was performed to evaluate patient factors affecting the accuracy of cup orientation in each navigation. The accuracy of cup inclination was 2.5° ± 2.2° in the 2D-3D group and 4.6° ± 3.3° in the PPM group (P = .0016). The accuracy of cup anteversion was 2.3° ± 1.7° in the 2D-3D group and 4.4° ± 3.3° in the PPM group (P = .0009). In the PPM group, the presence of roof osteophytes decreased the accuracy of cup inclination (odds ratio 8.27, P = .0140) and the absolute value of pelvic tilt had a negative influence on the accuracy of cup anteversion (odds ratio 1.27, P = .0222). In the 2D-3D group, patient factors had no effect on the accuracy of cup orientation. The accuracy of cup positioning in CT-based 2D-3D matched navigation was better than in paired-point matched navigation, and was not affected by patient factors. It is a useful system for even severely deformed pelvises such as developmental dysplasia of the hips. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. [Three-dimensional 3D modeling: First applications in radioanatomy and interventional radiology under CT guidance].

    PubMed

    Aubry, S; Pousse, A; Sarliève, P; Laborie, L; Delabrousse, E; Kastler, B

    2006-11-01

    To model vertebrae in 3D to improve radioanatomic knowledge of the spine with the vascular and nerve environment and simulate CT-guided interventions. Vertebra acquisitions were made with multidetector CT. We developed segmentation software and specific viewer software using the Delphi programming environment. This segmentation software makes it possible to model 3D high-resolution segments of vertebrae and their environment from multidetector CT acquisitions. Then the specific viewer software provides multiplanar reconstructions of the CT volume and the possibility to select different 3D objects of interest. This software package improves radiologists' radioanatomic knowledge through a new 3D anatomy presentation. Furthermore, the possibility of inserting virtual 3D objects in the volume can simulate CT-guided intervention. The first volumetric radioanatomic software has been born. Furthermore, it simulates CT-guided intervention and consequently has the potential to facilitate learning interventions using CT guidance.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balik, S; Weiss, E; Sleeman, W

    Purpose: To evaluate the potential impact of several setup error correction strategies on a proposed image-guided adaptive radiotherapy strategy for locally advanced lung cancer. Methods: Daily 4D cone-beam CT and weekly 4D fan-beam CT images were acquired from 9 lung cancer patients undergoing concurrent chemoradiation therapy. Initial planning CT was deformably registered to daily CBCT images to generate synthetic treatment courses. An adaptive radiation therapy course was simulated using the weekly CT images with replanning twice and a hypofractionated, simultaneous integrated boost to a total dose of 66 Gy to the original PTV and either a 66 Gy (no boost)more » or 82 Gy (boost) dose to the boost PTV (ITV + 3mm) in 33 fractions with IMRT or VMAT. Lymph nodes (LN) were not boosted (prescribed to 66 Gy in both plans). Synthetic images were rigidly, bony (BN) or tumor and carina (TC), registered to the corresponding plan CT, dose was computed on these from adaptive replans (PLAN) and deformably accumulated back to the original planning CT. Cumulative D98% of CTV of PT (ITV for 82Gy) and LN, and normal tissue dose changes were analyzed. Results: Two patients were removed from the study due to large registration errors. For the remaining 7 patients, D98% for CTV-PT (ITV-PT for 82 Gy) and CTV-LN was within 1 Gy of PLAN for both 66 Gy and 82 Gy plans with both setup techniques. Overall, TC based setup provided better results, especially for LN coverage (p = 0.1 for 66Gy plan and p = 0.2 for 82 Gy plan, comparison of BN and TC), though not significant. Normal tissue dose constraints violated for some patients if constraint was barely achieved in PLAN. Conclusion: The hypofractionated adaptive strategy appears to be deliverable with soft tissue alignment for the evaluated margins and planning parameters. Research was supported by NIH P01CA116602.« less

  19. An internet-based virtual coach to promote physical activity adherence in overweight adults: randomized controlled trial.

    PubMed

    Watson, Alice; Bickmore, Timothy; Cange, Abby; Kulshreshtha, Ambar; Kvedar, Joseph

    2012-01-26

    Addressing the obesity epidemic requires the development of effective, scalable interventions. Pedometers and Web-based programs are beneficial in increasing activity levels but might be enhanced by the addition of nonhuman coaching. We hypothesized that a virtual coach would increase activity levels, via step count, in overweight or obese individuals beyond the effect observed using a pedometer and website alone. We recruited 70 participants with a body mass index (BMI) between 25 and 35 kg/m(2) from the Boston metropolitan area. Participants were assigned to one of two study arms and asked to wear a pedometer and access a website to view step counts. Intervention participants also met with a virtual coach, an automated, animated computer agent that ran on their home computers, set goals, and provided personalized feedback. Data were collected and analyzed in 2008. The primary outcome measure was change in activity level (percentage change in step count) over the 12-week study, split into four 3-week time periods. Major secondary outcomes were change in BMI and participants' satisfaction. The mean age of participants was 42 years; the majority of participants were female (59/70, 84%), white (53/70, 76%), and college educated (68/70, 97%). Of the initial 70 participants, 62 completed the study. Step counts were maintained in intervention participants but declined in controls. The percentage change in step count between those in the intervention and control arms, from the start to the end, did not reach the threshold for significance (2.9% vs -12.8% respectively, P = .07). However, repeated measures analysis showed a significant difference when comparing percentage changes in step counts between control and intervention participants over all time points (analysis of variance, P = .02). There were no significant changes in secondary outcome measures. The virtual coach was beneficial in maintaining activity level. The long-term benefits and additional applications of this technology warrant further study. ClinicalTrials.gov NCT00792207; http://clinicaltrials.gov/ct2/show/NCT00792207 (Archived by WebCite at http://www.webcitation.org/63sm9mXUD).

  20. In vivo 3D PIXE-micron-CT imaging of Drosophila melanogaster using a contrast agent

    NASA Astrophysics Data System (ADS)

    Matsuyama, Shigeo; Hamada, Naoki; Ishii, Keizo; Nozawa, Yuichiro; Ohkura, Satoru; Terakawa, Atsuki; Hatori, Yoshinobu; Fujiki, Kota; Fujiwara, Mitsuhiro; Toyama, Sho

    2015-04-01

    In this study, we developed a three-dimensional (3D) computed tomography (CT) in vivo imaging system for imaging small insects with micrometer resolution. The 3D CT imaging system, referred to as 3D PIXE-micron-CT (PIXEμCT), uses characteristic X-rays produced by ion microbeam bombardment of a metal target. PIXEμCT was used to observe the body organs and internal structure of a living Drosophila melanogaster. Although the organs of the thorax were clearly imaged, the digestive organs in the abdominal cavity could not be clearly discerned initially, with the exception of the rectum and the Malpighian tubule. To enhance the abdominal images, a barium sulfate powder radiocontrast agent was added. For the first time, 3D images of the ventriculus of a living D. melanogaster were obtained. Our results showed that PIXEμCT can provide in vivo 3D-CT images that reflect correctly the structure of individual living organs, which is expected to be very useful in biological research.

  1. Tailoring four-dimensional cone-beam CT acquisition settings for fiducial marker-based image guidance in radiation therapy.

    PubMed

    Jin, Peng; van Wieringen, Niek; Hulshof, Maarten C C M; Bel, Arjan; Alderliesten, Tanja

    2018-04-01

    Use of four-dimensional cone-beam CT (4D-CBCT) and fiducial markers for image guidance during radiation therapy (RT) of mobile tumors is challenging due to the trade-off among image quality, imaging dose, and scanning time. This study aimed to investigate different 4D-CBCT acquisition settings for good visibility of fiducial markers in 4D-CBCT. Using these 4D-CBCTs, the feasibility of marker-based 4D registration for RT setup verification and manual respiration-induced motion quantification was investigated. For this, we applied a dynamic phantom with three different breathing motion amplitudes and included two patients with implanted markers. Irrespective of the motion amplitude, for a medium field of view (FOV), marker visibility was improved by reducing the imaging dose per projection and increasing the number of projection images; however, the scanning time was 4 to 8 min. For a small FOV, the total imaging dose and the scanning time were reduced (62.5% of the dose using a medium FOV, 2.5 min) without losing marker visibility. However, the body contour could be missing for a small FOV, which is not preferred in RT. The marker-based 4D setup verification was feasible for both the phantom and patient data. Moreover, manual marker motion quantification can achieve a high accuracy with a mean error of [Formula: see text].

  2. Feasibility of Using Volumetric Contrast-Enhanced Ultrasound with a 3-D Transducer to Evaluate Therapeutic Response after Targeted Therapy in Rabbit Hepatic VX2 Carcinoma.

    PubMed

    Kim, Jeehyun; Kim, Jung Hoon; Yoon, Soon Ho; Choi, Won Seok; Kim, Young Jae; Han, Joon Koo; Choi, Byung-Ihn

    2015-12-01

    The aim of this study was to assess the feasibility of using dynamic contrast-enhanced ultrasound (DCE-US) with a 3-D transducer to evaluate therapeutic responses to targeted therapy. Rabbits with hepatic VX2 carcinomas, divided into a treatment group (n = 22, 30 mg/kg/d sorafenib) and a control group (n = 13), were evaluated with DCE-US using 2-D and 3-D transducers and computed tomography (CT) perfusion imaging at baseline and 1 d after the first treatment. Perfusion parameters were collected, and correlations between parameters were analyzed. In the treatment group, both volumetric and 2-D DCE-US perfusion parameters, including peak intensity (33.2 ± 19.9 vs. 16.6 ± 10.7, 63.7 ± 20.0 vs. 30.1 ± 19.8), slope (15.3 ± 12.4 vs. 5.7 ± 4.5, 37.3 ± 20.4 vs. 15.7 ± 13.0) and area under the curve (AUC; 1004.1 ± 560.3 vs. 611.4 ± 421.1, 1332.2 ± 708.3 vs. 670.4 ± 388.3), had significantly decreased 1 d after the first treatment (p = 0.00). In the control group, 2-D DCE-US revealed that peak intensity, time to peak and slope had significantly changed (p < 0.05); however, volumetric DCE-US revealed that peak intensity, time-intensity AUC, AUC during wash-in and AUC during wash-out had significantly changed (p = 0.00). CT perfusion imaging parameters, including blood flow, blood volume and permeability of the capillary vessel surface, had significantly decreased in the treatment group (p = 0.00); however, in the control group, peak intensity and blood volume had significantly increased (p = 0.00). It is feasible to use DCE-US with a 3-D transducer to predict early therapeutic response after targeted therapy because perfusion parameters, including peak intensity, slope and AUC, significantly decreased, which is similar to the trend observed for 2-D DCE-US and CT perfusion imaging parameters. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Clinical coaching in primary care: Capable of improving control in patients with type 2 diabetes mellitus?

    PubMed

    González-Guajardo, Eduardo Enrique; Salinas-Martínez, Ana María; Botello-García, Antonio; Mathiew-Quiros, Álvaro

    2016-06-01

    Few clinical coaching studies are both endorsed by real cases and focused on reducing suboptimal diabetes control. We evaluated the effectiveness of coaching on improving type 2 diabetes goals after 3 years of implementation in primary care. A cross-sectional study with follow up was conducted during 2008-2011. Coaching consisted of guiding family doctors to improve their clinical abilities, and it was conducted by a medical doctor trained in skill building, experiential learning, and goal setting. Effectiveness was assessed by means of fasting plasma glucose and glycosylated hemoglobin outcomes. The main analysis consisted of 1×3 and 2×3 repeated measures ANOVAs. A significant coaching×time interaction was observed, indicating that the difference in glucose between primary care units with and without coaching increased over time (Wilks' lambda multivariate test, P<0.0001). Coaching increased 1.4 times (95%CI 1.3, 1.5) the possibility of reaching the fasting glucose goal after controlling for baseline values. There was also a significant improvement in glycosylated hemoglobin (Bonferroni-corrected p-value for pairwise comparisons, P<0.0001). A correctible and even preventable contributing component in diabetes care corresponds to physicians' performance. After 3 years of implementation, coaching was found to be worth the effort to improve type 2 diabetes control in primary care. Copyright © 2015 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.

  4. Improvements in Health Behaviors, Eating Self-Efficacy, and Goal-Setting Skills Following Participation in Wellness Coaching.

    PubMed

    Clark, Matthew M; Bradley, Karleah L; Jenkins, Sarah M; Mettler, Emily A; Larson, Brent G; Preston, Heather R; Liesinger, Juliette T; Werneburg, Brooke L; Hagen, Philip T; Harris, Ann M; Riley, Beth A; Olsen, Kerry D; Vickers Douglas, Kristin S

    2016-07-01

    Purpose . This project examined potential changes in health behaviors following wellness coaching. Design . In a single cohort study design, wellness coaching participants were recruited in 2011, data were collected through July 2012, and were analyzed through December 2013. Items in the study questionnaire used requested information about 11 health behaviors, self-efficacy for eating, and goal-setting skills. Setting . Worksite wellness center. Participants . One-hundred employee wellness center members with an average age of 42 years; 90% were female and most were overweight or obese. Intervention . Twelve weeks of in-person, one-on-one wellness coaching. Method . Participants completed study questionnaires when they started wellness coaching (baseline), after 12 weeks of wellness coaching, and at a 3-month follow-up. Results . From baseline to week 12, these 100 wellness coaching participants improved their self-reported health behaviors (11 domains, 0- to 10-point scale) from an average of 6.4 to 7.7 (p < .001), eating self-efficacy from an average of 112 to 142 (on a 0- to 180-point scale; p < .001), and goal-setting skills from an average of 49 to 55 (on a 16- to 80-point scale; p < .001). Conclusion . These results suggest that participants improved their current health behaviors and learned skills for continued healthy living. Future studies that use randomized controlled trials are needed to establish causality for wellness coaching.

  5. Web-Based Video-Coaching to Assist an Automated Computer-Tailored Physical Activity Intervention for Inactive Adults: A Randomized Controlled Trial.

    PubMed

    Alley, Stephanie; Jennings, Cally; Plotnikoff, Ronald C; Vandelanotte, Corneel

    2016-08-12

    Web-based physical activity interventions that apply computer tailoring have shown to improve engagement and behavioral outcomes but provide limited accountability and social support for participants. It is unknown how video calls with a behavioral expert in a Web-based intervention will be received and whether they improve the effectiveness of computer-tailored advice. The purpose of this study was to determine the feasibility and effectiveness of brief video-based coaching in addition to fully automated computer-tailored advice in a Web-based physical activity intervention for inactive adults. Participants were assigned to one of the three groups: (1) tailoring + video-coaching where participants received an 8-week computer-tailored Web-based physical activity intervention ("My Activity Coach") including 4 10-minute coaching sessions with a behavioral expert using a Web-based video-calling program (eg, Skype; n=52); (2) tailoring-only where participants received the same intervention without the coaching sessions (n=54); and (3) a waitlist control group (n=45). Demographics were measured at baseline, intervention satisfaction at week 9, and physical activity at baseline, week 9, and 6 months by Web-based self-report surveys. Feasibility was analyzed by comparing intervention groups on retention, adherence, engagement, and satisfaction using t tests and chi-square tests. Effectiveness was assessed using linear mixed models to compare physical activity changes between groups. A total of 23 tailoring + video-coaching participants, 30 tailoring-only participants, and 30 control participants completed the postintervention survey (83/151, 55.0% retention). A low percentage of tailoring + video-coaching completers participated in the coaching calls (11/23, 48%). However, the majority of those who participated in the video calls were satisfied with them (5/8, 71%) and had improved intervention adherence (9/11, 82% completed 3 or 4 modules vs 18/42, 43%, P=.01) and engagement (110 minutes spent on the website vs 78 minutes, P=.02) compared with other participants. There were no overall retention, adherence, engagement, and satisfaction differences between tailoring + video-coaching and tailoring-only participants. At 9 weeks, physical activity increased from baseline to postintervention in all groups (tailoring + video-coaching: +150 minutes/week; tailoring only: +123 minutes/week; waitlist control: +34 minutes/week). The increase was significantly higher in the tailoring + video-coaching group compared with the control group (P=.01). No significant difference was found between intervention groups and no significant between-group differences were found for physical activity change at 6 months. Only small improvements were observed when video-coaching was added to computer-tailored advice in a Web-based physical activity intervention. However, combined Web-based video-coaching and computer-tailored advice was effective in comparison with a control group. More research is needed to determine whether Web-based coaching is more effective than stand-alone computer-tailored advice. Australian New Zealand Clinical Trials Registry (ACTRN): 12614000339651; http://www.anzctr.org.au/TrialSearch.aspx?searchTxt=ACTRN12614000339651+&isBasic=True (Archived by WebCite at http://www.webcitation.org/6jTnOv0Ld).

  6. Improving Low-dose Cardiac CT Images based on 3D Sparse Representation

    PubMed Central

    Shi, Luyao; Hu, Yining; Chen, Yang; Yin, Xindao; Shu, Huazhong; Luo, Limin; Coatrieux, Jean-Louis

    2016-01-01

    Cardiac computed tomography (CCT) is a reliable and accurate tool for diagnosis of coronary artery diseases and is also frequently used in surgery guidance. Low-dose scans should be considered in order to alleviate the harm to patients caused by X-ray radiation. However, low dose CT (LDCT) images tend to be degraded by quantum noise and streak artifacts. In order to improve the cardiac LDCT image quality, a 3D sparse representation-based processing (3D SR) is proposed by exploiting the sparsity and regularity of 3D anatomical features in CCT. The proposed method was evaluated by a clinical study of 14 patients. The performance of the proposed method was compared to the 2D spares representation-based processing (2D SR) and the state-of-the-art noise reduction algorithm BM4D. The visual assessment, quantitative assessment and qualitative assessment results show that the proposed approach can lead to effective noise/artifact suppression and detail preservation. Compared to the other two tested methods, 3D SR method can obtain results with image quality most close to the reference standard dose CT (SDCT) images. PMID:26980176

  7. Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data.

    PubMed

    Forsberg, Daniel; Lindblom, Maria; Quick, Petter; Gauffin, Håkan

    2016-09-01

    To present a semi-automatic method with minimal user interaction for quantitative analysis of the patellofemoral motion pattern. 4D CT data capturing the patellofemoral motion pattern of a continuous flexion and extension were collected for five patients prone to patellar luxation both pre- and post-surgically. For the proposed method, an observer would place landmarks in a single 3D volume, which then are automatically propagated to the other volumes in a time sequence. From the landmarks in each volume, the measures patellar displacement, patellar tilt and angle between femur and tibia were computed. Evaluation of the observer variability showed the proposed semi-automatic method to be favorable over a fully manual counterpart, with an observer variability of approximately 1.5[Formula: see text] for the angle between femur and tibia, 1.5 mm for the patellar displacement, and 4.0[Formula: see text]-5.0[Formula: see text] for the patellar tilt. The proposed method showed that surgery reduced the patellar displacement and tilt at maximum extension with approximately 10-15 mm and 15[Formula: see text]-20[Formula: see text] for three patients but with less evident differences for two of the patients. A semi-automatic method suitable for quantification of the patellofemoral motion pattern as captured by 4D CT data has been presented. Its observer variability is on par with that of other methods but with the distinct advantage to support continuous motions during the image acquisition.

  8. Prognostic implications of 62Cu-diacetyl-bis (N4-methylthiosemicarbazone) PET/CT in patients with glioma.

    PubMed

    Toriihara, Akira; Ohtake, Makoto; Tateishi, Kensuke; Hino-Shishikura, Ayako; Yoneyama, Tomohiro; Kitazume, Yoshio; Inoue, Tomio; Kawahara, Nobutaka; Tateishi, Ukihide

    2018-05-01

    The potential of positron emission tomography/computed tomography using 62 Cu-diacetyl-bis (N 4 -methylthiosemicarbazone) ( 62 Cu-ATSM PET/CT), which was originally developed as a hypoxic tracer, to predict therapeutic resistance and prognosis has been reported in various cancers. Our purpose was to investigate prognostic value of 62 Cu-ATSM PET/CT in patients with glioma, compared to PET/CT using 2-deoxy-2-[ 18 F]fluoro-D-glucose ( 18 F-FDG). 56 patients with glioma of World Health Organization grade 2-4 were enrolled. All participants had undergone both 62 Cu-ATSM PET/CT and 18 F-FDG PET/CT within mean 33.5 days prior to treatment. Maximum standardized uptake value and tumor/background ratio were calculated within areas of increased radiotracer uptake. The prognostic significance for progression-free survival and overall survival were assessed by log-rank test and Cox's proportional hazards model. Disease progression and death were confirmed in 37 and 27 patients in follow-up periods, respectively. In univariate analysis, there was significant difference of both progression-free survival and overall survival in age, tumor grade, history of chemoradiotherapy, maximum standardized uptake value and tumor/background ratio calculated using 62 Cu-ATSM PET/CT. Multivariate analysis revealed that maximum standardized uptake value calculated using 62 Cu-ATSM PET/CT was an independent predictor of both progression-free survival and overall survival (p < 0.05). In a subgroup analysis including patients of grade 4 glioma, only the maximum standardized uptake values calculated using 62 Cu-ATSM PET/CT showed significant difference of progression-free survival (p < 0.05). 62 Cu-ATSM PET/CT is a more promising imaging method to predict prognosis of patients with glioma compared to 18 F-FDG PET/CT.

  9. 4D-CT scans reveal reduced magnitude of respiratory liver motion achieved by different abdominal compression plate positions in patients with intrahepatic tumors undergoing helical tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Yong, E-mail: hu.yong@zs-hospital.sh.cn; Zhou,

    Purpose: While abdominal compression (AC) can be used to reduce respiratory liver motion in patients receiving helical tomotherapy for hepatocellular carcinoma, the nature and extent of this effect is not well described. The purpose of this study was to evaluate the changes in magnitude of three-dimensional liver motion with abdominal compression using four-dimensional (4D) computed tomography (CT) images of several plate positions. Methods: From January 2012 to October 2015, 72 patients with intrahepatic carcinoma and divided into four groups underwent 4D-CT scans to assess respiratory liver motion. Of the 72 patients, 19 underwent abdominal compression of the cephalic area betweenmore » the subxiphoid and umbilicus (group A), 16 underwent abdominal compression of the caudal region between the subxiphoid area and the umbilicus (group B), 11 patients underwent abdominal compression of the caudal umbilicus (group C), and 26 patients remained free breathing (group D). 4D-CT images were sorted into ten-image series, according to the respiratory phase from the end inspiration to the end expiration, and then transferred to treatment planning software. All liver contours were drawn by a single physician and confirmed by a second physician. Liver relative coordinates were automatically generated to calculate the liver respiratory motion in different axial directions to compile the 10 ten contours into a single composite image. Differences in respiratory liver motion were assessed with a one-way analysis of variance test of significance. Results: The average respiratory liver motion in the Y axial direction was 4.53 ± 1.16, 7.56 ± 1.30, 9.95 ± 2.32, and 9.53 ± 2.62 mm in groups A, B, C, and D, respectively, with a significant change among the four groups (p < 0.001). Abdominal compression was most effective in group A (compression plate on the subxiphoid area), with liver displacement being 2.53 ± 0.93, 4.53 ± 1.16, and 2.14 ± 0.92 mm on the X-, Y-, and Z-axes, respectively. There was no significant difference in respiratory liver motion between group C (displacement: 3.23 ± 1.47, 9.95 ± 2.32, and 2.92 ± 1.10 mm on the X-, Y-, and Z-axes, respectively) and group D (displacement: 3.35 ± 1.55, 9.53 ± 2.62, and 3.35 ± 1.73 mm on the X-, Y-, and Z-axes, respectively). Abdominal compression was least effective in group C (compression on caudal umbilicus), with liver motion in this group similar to that of free-breathing patients (group D). Conclusions: 4D-CT scans revealed significant liver motion control via abdominal compression of the subxiphoid area; however, this control of liver motion was not observed with compression of the caudal umbilicus. The authors, therefore, recommend compression of the subxiphoid area in patients undergoing external radiotherapy for intrahepatic carcinoma.« less

  10. SU-E-J-106: The Use of Deformable Image Registration with Cone-Beam CT for a Better Evaluation of Cumulative Dose to Organs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fillion, O; Gingras, L; Archambault, L

    2015-06-15

    Purpose: The knowledge of dose accumulation in the patient tissues in radiotherapy helps in determining the treatment outcomes. This project aims at providing a workflow to map cumulative doses that takes into account interfraction organ motion without the need for manual re-contouring. Methods: Five prostate cancer patients were studied. Each patient had a planning CT (pCT) and 5 to 13 CBCT scans. On each series, a physician contoured the prostate, rectum, bladder, seminal vesicles and the intestine. First, a deformable image registration (DIR) of the pCTs onto the daily CBCTs yielded registered CTs (rCT) . This rCT combined the accuratemore » CT numbers of the pCT with the daily anatomy of the CBCT. Second, the original plans (220 cGy per fraction for 25 fractions) were copied on the rCT for dose re-calculation. Third, the DIR software Elastix was used to find the inverse transform from the rCT to the pCT. This transformation was then applied to the rCT dose grid to map the dose voxels back to their pCT location. Finally, the sum of these deformed dose grids for each patient was applied on the pCT to calculate the actual dose delivered to organs. Results: The discrepancy between the planned D98 and D2 and these indices re-calculated on the rCT, are, on average, of −1 ± 1 cGy and 1 ± 2 cGy per fraction, respectively. For fractions with large anatomical motion, the D98 discrepancy on the re-calculated dose grid mapped onto the pCT can raise to −17 ± 4 cGy. The obtained cumulative dose distributions illustrate the same behavior. Conclusion: This approach allowed the evaluation of cumulative doses to organs with the help of uncontoured daily CBCT scans. With this workflow, the easy evaluation of doses delivered for EBRT treatments could ultimately lead to a better follow-up of prostate cancer patients.« less

  11. Dosimetric Analysis of Organs at Risk During Expiratory Gating in Stereotactic Body Radiation Therapy for Pancreatic Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taniguchi, Cullen M.; Murphy, James D.; Eclov, Neville

    2013-03-15

    Purpose: To determine how the respiratory phase impacts dose to normal organs during stereotactic body radiation therapy (SBRT) for pancreatic cancer. Methods and Materials: Eighteen consecutive patients with locally advanced, unresectable pancreatic adenocarcinoma treated with SBRT were included in this study. On the treatment planning 4-dimensional computed tomography (CT) scan, the planning target volume (PTV), defined as the gross tumor volume plus 3-mm margin, the duodenum, and the stomach were contoured on the end-expiration (CT{sub exp}) and end-inspiration (CT{sub insp}) phases for each patient. A separate treatment plan was constructed for both phases with the dose prescription of 33 Gymore » in 5 fractions with 95% coverage of the PTV by the 100% isodose line. The dose-volume histogram (DVH) endpoints, volume of duodenum that received 20 Gy (V{sub 20}), V{sub 25}, and V{sub 30} and maximum dose to 5 cc of contoured organ (D{sub 5cc}), D{sub 1cc}, and D{sub 0.1cc}, were evaluated. Results: Dosimetric parameters for the duodenum, including V{sub 25}, V{sub 30}, D{sub 1cc}, and D{sub 0.1cc} improved by planning on the CT{sub exp} compared to those on the CT{sub insp}. There was a statistically significant overlap of the PTV with the duodenum but not the stomach during the CT{sub insp} compared to the CT{sub exp} (0.38 ± 0.17 cc vs 0.01 ± 0.01 cc, P=.048). A larger expansion of the PTV, in accordance with a Danish phase 2 trial, showed even more overlapping volume of duodenum on the CT{sub insp} compared to that on the CT{sub exp} (5.5 ± 0.9 cc vs 3.0 ± 0.8 cc, P=.0003) but no statistical difference for any stomach dosimetric DVH parameter. Conclusions: Dose to the duodenum was higher when treating on the inspiratory than on the expiratory phase. These data suggest that expiratory gating may be preferable to inspiratory breath-hold and free breathing strategies for minimizing risk of toxicity.« less

  12. Leadership power perception of amateur and professional soccer coaches and players according to their belief in good luck or not.

    PubMed

    Konter, Erkut

    2010-09-01

    The purpose of this study was to analyze the leadership power perception of amateur and professional soccer coaches and players according to their belief in good luck or not. Data collected from 165 male soccer coaches and 870 male soccer players including professionals and amateurs. The coaches had a mean age of 40.24 years (SD = 8.40) and had been coaching for an average of 8.56 years (SD = 6.75). The players had a mean age of 18.40 years (SD = 4.00) and had been playing soccer for an average of 6.00 years (SD = 4.15) with license. Adapted Turkish version of Power in Soccer Questionnaire-Other (PSQ-O for soccer players), Power in Soccer Questionnaire-Self (PSQ-S for coaches) and an information form were used for the data collection. Cronbach Reliability Alphas of PSQ-O and PSQ-S range between 0.60 and 0.84. Players' and coaches' data were analyzed by Kruskal-Wallis and Mann Whitney Tests. Analysis of PSQ-O revealed significant differences related to Coersive Power-CP [chi2 (3) = 8.46, p < 0.037], Referent Power-RP [chi2 (3) = 14.84, p < 0.002] and Expert Power-EP [chi2 (3) = 7.63, p < 0.054], and no significant differences related to Legitimate Power-LP (p > 0.05). Results of PSQ-O and PSQ-S indicated complex relationships related to belief in good luck or not. Overall, there are differences between coaches' and players'perception of CP, LP and EP related to belief in good luck or not. The only similarity appears to be in perception of RP. However, there is lack of research to make more certain conclusions. Future researchers should also take into consideration gender, sport experience, age, taking responsibility, self-confidence, attributions, expectations, superstitions, emotions, perception of achievement etc.

  13. Photophysics of 4-dimethylamino-4'-cyanostilbene and 4-azetidinyl-4'-cyanostilbene. Time-resolved fluorescence and trans-cis photoisomerisation

    NASA Astrophysics Data System (ADS)

    Il'ichev, Yurii V.; Kühnle, Wolfgang; Zachariasse, Klaas A.

    1996-11-01

    The fluorescence decays of trans-4-dimethylamino-4'-cyanostilbene (DCS) and trans-4-azetidinyl-4'-cyanostilbene (ACS) in an unpolar (n-heptane) and a polar (acetonitrile) solvent are single exponential down to a time resolution of around 5 ps and dual fluorescence is not observed. The dipole moment increases in two steps: from 7 D in the ground state via 13 D (DCS) or 10 D (ACS) for the Franck-Condon excited state to 21 D (DCS) or 22 D (ACS) for the relaxed fluorescing CT state. This means that the intramolecular charge transfer (ICT) in the excited state at most involves an intermediate with a subpicosecond lifetime. The presence of the azetidinyl group in ACS does not slow down the ICT reaction, contrary to what has been found for the 4-aminobenzonitriles, showing that inversion of the amino group is not an important reaction coordinate here. The activation energy Etc for trans-cis photoisomerisation is determined from the fluorescence decays in n-heptane (14.0 kJ/mol, DCS) and in acetonitrile (22.7 kJ/mol, DCS and 22.5 kJ/mol, ACS). This increase of Etc with solvent polarity, opposite to what has been found for trans-stilbene, shows that the photoisomerisation transition state is less polar than the CT state.

  14. The Mechanism of E2F/P130 Mediated Repression and Its Potential Tumor Suppressor Function in Breast Cancer

    DTIC Science & Technology

    2000-07-01

    conserved PLDLS motif. JBC 273, 8549-8552 (1998). 4. Nibu, Y., Zhang, H., and Levine, M . Interaction of short-range repressors with Drosophila CtBP in...oncogenic transformation. Proc. Natl. Acad. Sci. USA 92, 10467-10471 (1995). 11. Poortinga,G., Watanabe, M . & Parkhurst,S.M. Drosophila CtBP: A hairy...Levine, M . Groucho and dCtBP mediate separate pathways of transcriptional repression in the Drosophila embryo. Developmental Biology 96, 535-540 (1999). 13

  15. Ultrafast 3D balanced steady-state free precession MRI of the lung: Assessment of anatomic details in comparison to low-dose CT.

    PubMed

    Heye, Tobias; Sommer, Gregor; Miedinger, David; Bremerich, Jens; Bieri, Oliver

    2015-09-01

    To evaluate the anatomical details offered by a new single breath-hold ultrafast 3D balanced steady-state free precession (uf-bSSFP) sequence in comparison to low-dose chest computed tomography (CT). This was an Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant prospective study. A total of 20 consecutive patients enrolled in a lung cancer screening trial underwent same-day low-dose chest CT and 1.5T MRI. The presence of pulmonary nodules and anatomical details on 1.9 mm isotropic uf-bSSFP images was compared to 2 mm lung window reconstructions by two readers. The number of branching points on six predefined pulmonary arteries and the distance between the most peripheral visible vessel segment to the pleural surface on thin slices and 50 mm maximum intensity projections (MIP) were assessed. Image quality and sharpness of the pulmonary vasculature were rated on a 5-point scale. The uf-bSSFP detection rate of pulmonary nodules (32 nodules visible on CT and MRI, median diameter 3.9 mm) was 45.5% with 21 false-positive findings (pooled data of both readers). Uf-bSSFP detected 71.2% of branching points visible on CT data. The mean distance between peripheral vasculature and pleural surface was 13.0 ± 4.2 mm (MRI) versus 8.5 ± 3.3 mm (CT) on thin slices and 8.6 ± 3.9 mm (MRI) versus 4.6 ± 2.5 mm (CT) on MIPs. Median image quality and sharpness were rated 4 each. Although CT is superior to MRI, uf-bSSFP imaging provides good anatomical details with sufficient image quality and sharpness obtainable in a single breath-hold covering the entire chest. © 2014 Wiley Periodicals, Inc.

  16. Dose mapping: validation in 4D dosimetry with measurements and application in radiotherapy follow-up evaluation.

    PubMed

    Zhang, Geoffrey G; Huang, Tzung-Chi; Forster, Ken M; Lin, Kang-Ping; Stevens, Craig; Harris, Eleanor; Guerrero, Thomas

    2008-04-01

    The purpose of this paper is to validate a dose mapping program using optical flow method (OFM), and to demonstrate application of the program in radiotherapy follow-up evaluation. For the purpose of validation, the deformation matrices between four-dimensional (4D) CT data of different simulated respiration phases of a phantom were calculated using OFM. The matrices were then used to map doses of all phases to a single-phase image, and summed in equal time weighting. The calculated dose should closely represent the dose delivered to the moving phantom if the deformation matrices are accurately calculated. The measured point doses agreed with the OFM calculations better than 2% at isocenters, and dose distributions better than 1mm for the 50% isodose line. To demonstrate proof-of-concept for the use of deformable image registration in dose mapping for treatment evaluation, the treatment-planning CT was registered with the post-treatment CT image from the positron emission tomography (PET)/CT resulting in a deformation matrix. The dose distribution from the treatment plan was then mapped onto the restaging PET/CT using the deformation matrix. Two cases in which patients had thoracic malignancies are presented. Each patient had CT-based treatment planning for radiotherapy and restaging fluorodeoxy glucose (FDG)-PET/CT imaging 4-6 weeks after completion of treatments. Areas of pneumonitis and recurrence were identified radiographically on both PET and CT restaging images. Local dose and standard uptake values for pneumonitis and recurrence were studied as a demonstration of this method. By comparing the deformable mapped dose to measurement, the treatment evaluation method which is introduced in this manuscript proved to be accurate. It thus provides a more accurate analysis than other rigid or linear dose-image registration when used in studying treatment outcome versus dose.

  17. Health coaching by medical assistants to improve control of diabetes, hypertension, and hyperlipidemia in low-income patients: a randomized controlled trial.

    PubMed

    Willard-Grace, Rachel; Chen, Ellen H; Hessler, Danielle; DeVore, Denise; Prado, Camille; Bodenheimer, Thomas; Thom, David H

    2015-03-01

    Health coaching by medical assistants could be a financially viable model for providing self-management support in primary care if its effectiveness were demonstrated. We investigated whether in-clinic health coaching by medical assistants improves control of cardiovascular and metabolic risk factors when compared with usual care. We conducted a 12-month randomized controlled trial of 441 patients at 2 safety net primary care clinics in San Francisco, California. The primary outcome was a composite measure of being at or below goal at 12 months for at least 1 of 3 uncontrolled conditions at baseline as defined by hemoglobin A1c, systolic blood pressure, and low-density lipoprotein (LDL) cholesterol. Secondary outcomes were meeting all 3 goals and meeting individual goals. Data were analyzed using χ(2) tests and linear regression models. Participants in the coaching arm were more likely to achieve both the primary composite measure of 1 of the clinical goals (46.4% vs 34.3%, P = .02) and the secondary composite measure of reaching all clinical goals (34.0% vs 24.7%, P = .05). Almost twice as many coached patients achieved the hemoglobin A1c goal (48.6% vs 27.6%, P = .01). At the larger study site, coached patients were more likely to achieve the LDL cholesterol goal (41.8% vs 25.4%, P = .04). The proportion of patients meeting the systolic blood pressure goal did not differ significantly. Medical assistants serving as in-clinic health coaches improved control of hemoglobin A1c and LDL levels, but not blood pressure, compared with usual care. Our results highlight the need to understand the relationship between patients' clinical conditions, interventions, and the contextual features of implementation. © 2015 Annals of Family Medicine, Inc.

  18. Health Coaching by Medical Assistants to Improve Control of Diabetes, Hypertension, and Hyperlipidemia in Low-Income Patients: A Randomized Controlled Trial

    PubMed Central

    Willard-Grace, Rachel; Chen, Ellen H.; Hessler, Danielle; DeVore, Denise; Prado, Camille; Bodenheimer, Thomas; Thom, David H.

    2015-01-01

    PURPOSE Health coaching by medical assistants could be a financially viable model for providing self-management support in primary care if its effectiveness were demonstrated. We investigated whether in-clinic health coaching by medical assistants improves control of cardiovascular and metabolic risk factors when compared with usual care. METHODS We conducted a 12-month randomized controlled trial of 441 patients at 2 safety net primary care clinics in San Francisco, California. The primary outcome was a composite measure of being at or below goal at 12 months for at least 1 of 3 uncontrolled conditions at baseline as defined by hemoglobin A1c, systolic blood pressure, and low-density lipoprotein (LDL) cholesterol. Secondary outcomes were meeting all 3 goals and meeting individual goals. Data were analyzed using χ2 tests and linear regression models. RESULTS Participants in the coaching arm were more likely to achieve both the primary composite measure of 1 of the clinical goals (46.4% vs 34.3%, P = .02) and the secondary composite measure of reaching all clinical goals (34.0% vs 24.7%, P = .05). Almost twice as many coached patients achieved the hemoglobin A1c goal (48.6% vs 27.6%, P = .01). At the larger study site, coached patients were more likely to achieve the LDL cholesterol goal (41.8% vs 25.4%, P = .04). The proportion of patients meeting the systolic blood pressure goal did not differ significantly. CONCLUSIONS Medical assistants serving as in-clinic health coaches improved control of hemoglobin A1c and LDL levels, but not blood pressure, compared with usual care. Our results highlight the need to understand the relationship between patients’ clinical conditions, interventions, and the contextual features of implementation. PMID:25755034

  19. Microvascular transplants in head and neck reconstruction: 3D evaluation of volume loss.

    PubMed

    Bittermann, Gido; Thönissen, Philipp; Poxleitner, Philipp; Zimmerer, Ruediger; Vach, Kirstin; Metzger, Marc C

    2015-10-01

    Despite oversized latissimus dorsi free flap reconstruction in the head and neck area, esthetic and functional problems continue to exist due to the well-known occurrence of transplant shrinkage. The purpose of this study was to acquire an estimation of the volume and time of the shrinkage process. The assessment of volume loss was performed using a 3D evaluation of two postoperative CT scans. A retrospective review was conducted on all latissimus dorsi free flap reconstructions performed between 2004 and 2013. Inclusion criteria for the assessment were: resection of an oral carcinoma and microsurgical defect coverage with latissimus dorsi free flap; a first postoperative CT (CT1) performed between 3 weeks and a maximum of 3 months after reconstruction surgery; and an additional CT scan (CT2) performed at least one year postoperatively. The exclusion criterion was surgical intervention in the local area between the acquisition of CT1 and CT2. The effect of adjuvant radiation therapy was considered. Volume determination of the transplant was carried out in CT1 and CT2 by manual segmentation of the graft. Fifteen patients were recruited. 3D evaluation showed an average volume loss of 34.4%. In the consideration of postoperative radiotherapy the volume reduction was 39.2% in patients with radiotherapy and 31.3% in patients without radiotherapy. The reconstruction flap volume required for overcorrection of the surgical defect was investigated. This study indicates that a volume loss of more than 30% could be expected one or more years after latissimus dorsi free flap reconstruction. Clinical trial number DRKS00007534. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Participant experiences in a smartphone-based health coaching intervention for type 2 diabetes: A qualitative inquiry.

    PubMed

    Pludwinski, Sarah; Ahmad, Farah; Wayne, Noah; Ritvo, Paul

    2016-04-01

    We investigated the experience of individuals diagnosed with type 2 diabetes mellitus (T2DM) who participated in an intervention in which the key elements were the provision of a smartphone and self-monitoring software. The interviews focused on use of a smartphone and the effects on motivation for health behavior change. This was a qualitative evaluation of participants in a larger T2DM self-management randomized controlled trial (RCT) conducted at the Black Creek Community Health Centre (BCCHC) in Toronto, Canada (ClinicalTrials.gov Identifier: NCT02036892). The study is based on semi-structured interviews (n = 11) that were audio taped and analyzed with a thematic analytic approach. The RCT compared the effectiveness of six months of smartphone-based self-monitoring and health coaching with a control group who received health coaching without internet or smartphone-based assistance. Qualitative data analyses resulted in derivation of four major themes that describe participant experience: (a) 'smartphone and software', describes smartphone use in relation to health behavior change; (b) 'health coach' describes how client/health coach relationships were assisted by smartphone use; (c) 'overall experience' describes perceptions of the overall intervention; and (d) 'frustrations in managing chronic conditions' describes difficulties with the complexities of T2DM management from a patient perspective. Findings suggest that interventions with T2DM assisted by smartphone software and health coaches actively engage individuals in improved hemoglobin A1c (HbA1c) control. © The Author(s) 2015.

  1. Objective and subjective comparison of standard 2-D and fully 3-D reconstructed data on a PET/CT system.

    PubMed

    Strobel, Klaus; Rüdy, Matthias; Treyer, Valerie; Veit-Haibach, Patrick; Burger, Cyrill; Hany, Thomas F

    2007-07-01

    The relative advantage of fully 3-D versus 2-D mode for whole-body imaging is currently the focus of considerable expert debate. The nature of 3-D PET acquisition for FDG PET/CT theoretically allows a shorter scan time and improved efficiency of FDG use than in the standard 2-D acquisition. We therefore objectively and subjectively compared standard 2-D and fully 3-D reconstructed data for FDG PET/CT on a research PET/CT system. In a total of 36 patients (mean 58.9 years, range 17.3-78.9 years; 21 male, 15 female) referred for known or suspected malignancy, FDG PET/CT was performed using a research PET/CT system with advanced detector technology with improved sensitivity and spatial resolution. After 45 min uptake, a low-dose CT (40 mAs) from head to thigh was performed followed by 2-D PET (emission 3 min per field) and 3-D PET (emission 1.5 min per field) with both seven slices overlap to cover the identical anatomical region. Acquisition time was therefore 50% less (seven fields; 21 min vs. 10.5 min). PET data was acquired in a randomized fashion, so in 50% of the cases 2-D data was acquired first. CT data was used for attenuation correction. 2-D (OSEM) and 3-D PET images were iteratively reconstructed. Subjective analysis of 2-D and 3-D images was performed by two readers in a blinded, randomized fashion evaluating the following criteria: sharpness of organs (liver, chest wall/lung), overall image quality and detectability and dignity of each identified lesion. Objective analysis of PET data was investigated measuring maximum standard uptake value with lean body mass (SUV(max,LBM)) of identified lesions. On average, per patient, the SUV(max) was 7.86 (SD 7.79) for 2-D and 6.96 (SD 5.19) for 3-D. On a lesion basis, the average SUV(max) was 7.65 (SD 7.79) for 2-D and 6.75 (SD 5.89) for 3-D. The absolute difference on a paired t-test of SUV 3-D-2-D based on each measured lesion was significant with an average of -0.956 (P=0.002) and an average of -0.884 on a patient base (P<0.05). With 3-D the SUV(max) decreased by an average of 5.2% for each lesion, and an average of 6.0% for each patient. Subjective analysis showed fair inter-observer agreement regarding detectability (kappa=0.24 for 3-D; 0.36 for 3-D) and dignity (kappa=0.44 for 3-D and 0.4 for 2-D) of the lesions. There was no significant diagnostic difference between 3-D and 2-D. Only in one patient, a satellite liver metastasis of a colon cancer was missed in 3-D and detected only in 2-D. On average, the overall image quality for 3-D images was equal (in 24%) or inferior (in 76%) compared to 2-D. A possible major advantage of 3-D data acquisition is the faster patient throughput with a 50% reduction in scan time. The fully 3-D reconstruction technique has overcome the technical drawbacks of current 3-D imaging technique. In our limited number of patients there was no significant diagnostic difference between 2-D and fully 3-D.

  2. An examination of current practices and gender differences in strength and conditioning in a sample of varsity high school athletic programs.

    PubMed

    Reynolds, Monica L; Ransdell, Lynda B; Lucas, Shelley M; Petlichkoff, Linda M; Gao, Yong

    2012-01-01

    Currently, little is known about strength and conditioning programs at the high school level. Therefore, the purpose of this research was to explore current practices in strength and conditioning for varsity high school athletes in selected sports. The following were specifically examined: who administers programs for these athletes, what kinds of training activities are done, and whether the responsible party or emphasis changes depending on the gender of the athletes. Coaches of varsity soccer, basketball, softball, and baseball in 3 large Idaho school districts were asked to complete an online survey. Sixty-seven percent (32/48) of the questionnaires were completed and used for the study. The majority of coaches (84%) provided strength and conditioning opportunities for their athletes, although only 37% required participation. Strength training programs were designed and implemented primarily by either physical education teachers or head coaches. Compared with coaches of male athletes, coaches of female athletes were less likely to know the credentials of their strength coaches, and they were less likely to use certified coaches to plan and implement their strength and conditioning programs. Most programs included dynamic warm-ups and cool-downs, plyometrics, agility training, speed training, and conditioning, and most programs were conducted 3 d·wk(-1) (76%) for sessions lasting between 30 and 59 minutes (63%). Compared with their female counterparts, male athletes were more likely to have required training, participate in strength training year round, and train using more sessions per week. This study provides additional information related to the practice of strength and conditioning in a sample of high school athletic teams.

  3. SU-E-J-153: Reconstructing 4D Cone Beam CT Images for Clinical QA of Lung SABR Treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beaudry, J; Bergman, A; British Columbia Cancer Agency, Vancouver, BC

    Purpose: To verify that the planned Primary Target Volume (PTV) and Internal Gross Tumor Volume (IGTV) fully enclose a moving lung tumor volume as visualized on a pre-SABR treatment verification 4D Cone Beam CT. Methods: Daily 3DCBCT image sets were acquired immediately prior to treatment for 10 SABR lung patients using the on-board imaging system integrated into a Varian TrueBeam (v1.6: no 4DCBCT module available). Respiratory information was acquired during the scan using the Varian RPM system. The CBCT projections were sorted into 8 bins offline, both by breathing phase and amplitude, using in-house software. An iterative algorithm based onmore » total variation minimization, implemented in the open source reconstruction toolkit (RTK), was used to reconstruct the binned projections into 4DCBCT images. The relative tumor motion was quantified by tracking the centroid of the tumor volume from each 4DCBCT image. Following CT-CBCT registration, the planning CT volumes were compared to the location of the CBCT tumor volume as it moves along its breathing trajectory. An overlap metric quantified the ability of the planned PTV and IGTV to contain the tumor volume at treatment. Results: The 4DCBCT reconstructed images visibly show the tumor motion. The mean overlap between the planned PTV (IGTV) and the 4DCBCT tumor volumes was 100% (94%), with an uncertainty of 5% from the 4DCBCT tumor volume contours. Examination of the tumor motion and overlap metric verify that the IGTV drawn at the planning stage is a good representation of the tumor location at treatment. Conclusion: It is difficult to compare GTV volumes from a 4DCBCT and a planning CT due to image quality differences. However, it was possible to conclude the GTV remained within the PTV 100% of the time thus giving the treatment staff confidence that SABR lung treatements are being delivered accurately.« less

  4. Improving the Diagnostic Specificity of CT for Early Detection of Lung Cancer: 4D CT-Based Pulmonary Nodule Elastometry

    DTIC Science & Technology

    2013-08-01

    transformation models, such as thin - plate spline (1-3) or elastic-body spline (4, 5), is locally controlled. One of the main motivations behind the...research project. References: 1. Bookstein FL. Principal warps: thin - plate splines and the decomposition of deformations. IEEE Transactions on Pattern...Rohr K, Stiehl HS, Sprengel R, Buzug TM, Weese J, Kuhn MH. Landmark-based elastic registration using approximating thin - plate splines . IEEE Transactions

  5. Improving the Diagnostic Specificity of CT for Early Detection of Lung Cancer: 4D CT-Based Pulmonary Nodule Elastometry

    DTIC Science & Technology

    2013-08-01

    as thin - plate spline (1-3) or elastic-body spline (4, 5), is locally controlled. One of the main motivations behind the use of B- spline ...FL. Principal warps: thin - plate splines and the decomposition of deformations. IEEE Transactions on Pattern Analysis and Machine Intelligence...Weese J, Kuhn MH. Landmark-based elastic registration using approximating thin - plate splines . IEEE Transactions on Medical Imaging. 2001;20(6):526-34

  6. Investigating existing medical CT segmentation techniques within automated baggage and package inspection

    NASA Astrophysics Data System (ADS)

    Megherbi, Najla; Breckon, Toby P.; Flitton, Greg T.

    2013-10-01

    3D Computed Tomography (CT) image segmentation is already well established tool in medical research and in routine daily clinical practice. However, such techniques have not been used in the context of 3D CT image segmentation for baggage and package security screening using CT imagery. CT systems are increasingly used in airports for security baggage examination. We propose in this contribution an investigation of the current 3D CT medical image segmentation methods for use in this new domain. Experimental results of 3D segmentation on real CT baggage security imagery using a range of techniques are presented and discussed.

  7. Three-dimensional monochromatic x-ray CT

    NASA Astrophysics Data System (ADS)

    Saito, Tsuneo; Kudo, Hiroyuki; Takeda, Tohoru; Itai, Yuji; Tokumori, Kenji; Toyofuku, Fukai; Hyodo, Kazuyuki; Ando, Masami; Nishimura, Ktsuyuki; Uyama, Chikao

    1995-08-01

    In this paper, we describe a 3D computed tomography (3D CT) using monochromatic x-rays generated by synchrotron radiation, which performs a direct reconstruction of 3D volume image of an object from its cone-beam projections. For the develpment of 3D CT, scanning orbit of x-ray source to obtain complete 3D information about an object and corresponding 3D image reconstruction algorithm are considered. Computer simulation studies demonstrate the validities of proposed scanning method and reconstruction algorithm. A prototype experimental system of 3D CT was constructed. Basic phantom examinations and specific material CT image by energy subtraction obtained in this experimental system are shown.

  8. Decentralization Does Not Assure Optimal Delivery of PMTCT and HIV-Exposed Infant Services in a Low Prevalence Setting

    PubMed Central

    Edmonds, Andrew; Feinstein, Lydia; Okitolonda, Vitus; Thompson, Deidre; Kawende, Bienvenu; Behets, Frieda

    2016-01-01

    Background The consequences of decentralizing prevention of mother-to-child HIV transmission and HIV-exposed infant services to antenatal care (ANC)/labor and delivery (L&D) sites from dedicated HIV care and treatment (C&T) centers remain unknown, particularly in low prevalence settings. Methods In a cohort of mother–infant pairs, we compared delivery of routine services at ANC/L&D and C&T facilities in Kinshasa, Democratic Republic of Congo from 2010–2013, using methods accounting for competing risks (eg, death). Women could opt to receive interventions at 90 decentralized ANC/L&D sites, or 2 affiliated C&T centers. Additionally, we assessed decentralization’s population-level impacts by comparing proportions of women and infants receiving interventions before (2009–2010) and after (2011–2013) decentralization. Results Among newly HIV-diagnosed women (N = 1482), the 14-week cumulative incidence of receiving the package of CD4 testing and zidovudine or antiretroviral therapy was less at ANC/L&D [66%; 95% confidence interval (CI): 63% to 69%] than at C&T (88%; 95% CI: 83% to 92%) sites (subdistribution hazard ratio, 0.62; 95% CI: 0.55 to 0.69). Delivery of cotrimoxazole and DNA polymerase chain reaction testing to HIV-exposed infants (N = 1182) was inferior at ANC/L&D sites (subdistribution hazard ratio, 0.84; 95% CI: 0.76 to 0.92); the 10-month cumulative incidence of the package at ANC/L&D sites was 89% (95% CI: 82% to 93%) versus 97% (95% CI: 93% to 99%) at C&T centers. Receipt of the pregnancy (20% of 1518, to 64% of 1405) and infant (16%–31%) packages improved post decentralization. Conclusions Services were delivered less efficiently at ANC/L&D sites than C&T centers. Although access improved with decentralization, its potential cannot be realized without sufficient and sustained support. PMID:26262776

  9. TH-EF-207A-05: Feasibility of Applying SMEIR Method On Small Animal 4D Cone Beam CT Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong, Y; Zhang, Y; Shao, Y

    Purpose: Small animal cone beam CT imaging has been widely used in preclinical research. Due to the higher respiratory rate and heat beats of small animals, motion blurring is inevitable and needs to be corrected in the reconstruction. Simultaneous motion estimation and image reconstruction (SMEIR) method, which uses projection images of all phases, proved to be effective in motion model estimation and able to reconstruct motion-compensated images. We demonstrate the application of SMEIR for small animal 4D cone beam CT imaging by computer simulations on a digital rat model. Methods: The small animal CBCT imaging system was simulated with themore » source-to-detector distance of 300 mm and the source-to-object distance of 200 mm. A sequence of rat phantom were generated with 0.4 mm{sup 3} voxel size. The respiratory cycle was taken as 1.0 second and the motions were simulated with a diaphragm motion of 2.4mm and an anterior-posterior expansion of 1.6 mm. The projection images were calculated using a ray-tracing method, and 4D-CBCT were reconstructed using SMEIR and FDK methods. The SMEIR method iterates over two alternating steps: 1) motion-compensated iterative image reconstruction by using projections from all respiration phases and 2) motion model estimation from projections directly through a 2D-3D deformable registration of the image obtained in the first step to projection images of other phases. Results: The images reconstructed using SMEIR method reproduced the features in the original phantom. Projections from the same phase were also reconstructed using FDK method. Compared with the FDK results, the images from SMEIR method substantially improve the image quality with minimum artifacts. Conclusion: We demonstrate that it is viable to apply SMEIR method to reconstruct small animal 4D-CBCT images.« less

  10. Elite Youth Soccer Players' Physiological Responses, Time-Motion Characteristics, and Game Performance in 4 vs. 4 Small-Sided Games: The Influence of Coach Feedback.

    PubMed

    Brandes, Mirko; Elvers, Sebastian

    2017-10-01

    The purpose of this study was to determine the impact of mild vs. strongly pushed coach feedback on the physiological response, ratio of perceived exertion (RPE), and time-motion characteristics in soccer training with small-sided games (SSGs). Sixteen elite youth soccer players (aged 17.2 ± 0.7 years, V[Combining Dot Above]O2max 62.1 ± 3.8 ml·kg·min) played two 4 vs. 4 small-sided games each. In random order, the coach provided a mild, unobtrusive, or a strongly pushed feedback throughout the game. Physiological measurements included heart rate expressed in mean values and intensity zones, blood lactate concentration, and RPE. The distance traveled, number of sprints, and work:rest ratio were captured by global positioning systems at 5 Hz. Game performance, such as volume of play and efficacy index, was estimated using the Team Sports Assessment Procedure. No differences were found for the physiological response and time-motion characteristics, but effect sizes demonstrated an increase in RPE (+0.4, p = 0.27) and a decrease in game performance (e.g., volume of play, -2.5, p = 0.08) under pushed feedback. Although a pushed feedback raises RPE, it negatively affected the players' game performance, without necessarily provoking higher physiological responses. These results should help coaches to understand that modifying the type of feedback provided during SSG does not impact the physiological response if SSG are already played with high intensity but that the feedback affects RPE and game performance. To keep a better game performance, soccer coaches are encouraged to provide smooth feedback during SSG.

  11. Chondral Rib Fractures in Professional American Football: Two Cases and Current Practice Patterns Among NFL Team Physicians.

    PubMed

    McAdams, Timothy R; Deimel, Jay F; Ferguson, Jeff; Beamer, Brandon S; Beaulieu, Christopher F

    2016-02-01

    Although a recognized and discussed injury, chondral rib fractures in professional American football have not been previously reported in the literature. There currently exists no consensus on how to identify and treat these injuries or the expected return to play for the athlete. To present 2 cases of chondral rib injuries in the National Football League (NFL) and discuss the current practice patterns for management of these injuries among the NFL team physicians. Case series; Level of evidence, 4. Two cases of NFL players with chondral rib injuries are presented. A survey regarding work-up and treatment of these injuries was completed by team physicians at the 2014 NFL Combine. Our experience in identifying and treating these injuries is presented in conjunction with a survey of NFL team physicians' experiences. Two cases of rib chondral injuries were diagnosed by computed tomography (CT) and treated with rest and protective splinting. Return to play was 2 to 4 weeks. NFL Combine survey results show that NFL team physicians see a mean of 4 costal cartilage injuries per 5-year period, or approximately 1 case per year per team. Seventy percent of team physicians use CT scanning and 43% use magnetic resonance imaging for diagnosis of these injuries. An anesthetic block is used acutely in 57% and only electively in subsequent games by 39%. A high index of suspicion is necessary to diagnose chondral rib injuries in American football. CT scan is most commonly used to confirm diagnosis. Return to play can take up to 2 to 4 weeks with a protective device, although anesthetic blocks can be used to potentially expedite return. Chondral rib injuries are common among NFL football players, while there is no literature to support proper diagnosis and treatment of these injuries or expected duration of recovery. These injuries are likely common in other contact sports and levels of competition as well. Our series combined with NFL team physician survey results can aid team physicians in identifying these injuries, obtaining useful imaging, and counseling players and coaches and the expected time of recovery.

  12. Prescribed and self-reported seasonal training of distance runners.

    PubMed

    Hewson, D J; Hopkins, W G

    1995-12-01

    A survey of 123 distance-running coaches and their best runners was undertaken to describe prescribed seasonal training and its relationship to the performance and self-reported training of the runners. The runners were 43 females and 80 males, aged 24 +/- 8 years (mean +/- S.D.), training for events from 800 m to the marathon, with seasonal best paces of 86 +/- 6% of sex- and age-group world records. The coaches and runners completed a questionnaire on typical weekly volumes of interval and strength training, and typical weekly volumes and paces of moderate and hard continuous running, for build-up, pre-competition, competition and post-competition phases of a season. Prescribed training decreased in volume and increased in intensity from the build-up through to the competition phase, and had similarities with 'long slow distance' training. Coaches of the faster runners prescribed longer build-ups, greater volumes of moderate continuous running and slower relative paces of continuous running (r = 0.19-0.36, P < 0.05), suggesting beneficial effects of not training close to competition pace. The mean training volumes and paces prescribed by the coaches were similar to those reported by the runners, but the correlations between prescribed and reported training were poor (r = 0.2-0.6). Coaches may therefore need to monitor their runners' training more closely.

  13. 4D XCAT phantom for multimodality imaging research

    PubMed Central

    Segars, W. P.; Sturgeon, G.; Mendonca, S.; Grimes, Jason; Tsui, B. M. W.

    2010-01-01

    Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ‘‘Basic anatomical and physiological data for use in radiological protection: reference values,” ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce realistic, predictive 3D and 4D imaging data from populations of normal and abnormal patients under various imaging parameters, the authors conclude that the XCAT provides an important tool in imaging research to evaluate and improve imaging devices and techniques. In the field of x-ray CT, the phantom may also provide the necessary foundation with which to optimize clinical CT applications in terms of image quality versus radiation dose, an area of research that is becoming more significant with the growing use of CT. PMID:20964209

  14. The Effect of Intensity on 3-Dimensional Kinematics and Coordination in Front-Crawl Swimming.

    PubMed

    de Jesus, Kelly; Sanders, Ross; de Jesus, Karla; Ribeiro, João; Figueiredo, Pedro; Vilas-Boas, João P; Fernandes, Ricardo J

    2016-09-01

    Coaches are often challenged to optimize swimmers' technique at different training and competition intensities, but 3-dimensional (3D) analysis has not been conducted for a wide range of training zones. To analyze front-crawl 3D kinematics and interlimb coordination from low to severe swimming intensities. Ten male swimmers performed a 200-m front crawl at 7 incrementally increasing paces until exhaustion (0.05-m/s increments and 30-s intervals), with images from 2 cycles in each step (at the 25- and 175-m laps) being recorded by 2 surface and 4 underwater video cameras. Metabolic anaerobic threshold (AnT) was also assessed using the lactate-concentration-velocity curve-modeling method. Stroke frequency increased, stroke length decreased, hand and foot speed increased, and the index of interlimb coordination increased (within a catch-up mode) from low to severe intensities (P ≤ .05) and within the 200-m steps performed above the AnT (at or closer to the 4th step; P ≤ .05). Concurrently, intracyclic velocity variations and propelling efficiency remained similar between and within swimming intensities (P > .05). Swimming intensity has a significant impact on swimmers' segmental kinematics and interlimb coordination, with modifications being more evident after the point when AnT is reached. As competitive swimming events are conducted at high intensities (in which anaerobic metabolism becomes more prevalent), coaches should implement specific training series that lead swimmers to adapt their technique to the task constraints that exist in nonhomeostatic race conditions.

  15. Four-dimensional dose reconstruction through in vivo phase matching of cine images of electronic portal imaging device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoon, Jihyung; Jung, Jae Won, E-mail: jungj@ecu.ed

    Purpose: A method is proposed to reconstruct a four-dimensional (4D) dose distribution using phase matching of measured cine images to precalculated images of electronic portal imaging device (EPID). Methods: (1) A phantom, designed to simulate a tumor in lung (a polystyrene block with a 3 cm diameter embedded in cork), was placed on a sinusoidally moving platform with an amplitude of 1 cm and a period of 4 s. Ten-phase 4D computed tomography (CT) images of the phantom were acquired. A planning target volume (PTV) was created by adding a margin of 1 cm around the internal target volume ofmore » the tumor. (2) Three beams were designed, which included a static beam, a theoretical dynamic beam, and a planning-optimized dynamic beam (PODB). While the theoretical beam was made by manually programming a simplistic sliding leaf motion, the planning-optimized beam was obtained from treatment planning. From the three beams, three-dimensional (3D) doses on the phantom were calculated; 4D dose was calculated by means of the ten phase images (integrated over phases afterward); serving as “reference” images, phase-specific EPID dose images under the lung phantom were also calculated for each of the ten phases. (3) Cine EPID images were acquired while the beams were irradiated to the moving phantom. (4) Each cine image was phase-matched to a phase-specific CT image at which common irradiation occurred by intercomparing the cine image with the reference images. (5) Each cine image was used to reconstruct dose in the phase-matched CT image, and the reconstructed doses were summed over all phases. (6) The summation was compared with forwardly calculated 4D and 3D dose distributions. Accounting for realistic situations, intratreatment breathing irregularity was simulated by assuming an amplitude of 0.5 cm for the phantom during a portion of breathing trace in which the phase matching could not be performed. Intertreatment breathing irregularity between the time of treatment and the time of planning CT was considered by utilizing the same reduced amplitude when the phantom was irradiated. To examine the phase matching in a humanoid environment, the matching was also performed in a digital phantom (4D XCAT phantom). Results: For the static, the theoretical, and the planning-optimized dynamic beams, the 4D reconstructed doses showed agreement with the forwardly calculated 4D doses within the gamma pass rates of 92.7%, 100%, and 98.1%, respectively, at the isocenter plane given by 3%/3 mm criteria. Excellent agreement in dose volume histogram of PTV and lung-PTV was also found between the two 4D doses, while substantial differences were found between the 3D and the 4D doses. The significant breathing irregularities modeled in this study were found not to be noticeably affecting the reconstructed dose. The phase matching was performed equally well in a digital phantom. Conclusions: The method of retrospective phase determination of a moving object under irradiation provided successful 4D dose reconstruction. This method will provide accurate quality assurance and facilitate adaptive therapy when distinguishable objects such as well-defined tumors, diaphragm, and organs with markers (pancreas and liver) are covered by treatment beam apertures.« less

  16. Four-dimensional dose reconstruction through in vivo phase matching of cine images of electronic portal imaging device.

    PubMed

    Yoon, Jihyung; Jung, Jae Won; Kim, Jong Oh; Yi, Byong Yong; Yeo, Inhwan

    2016-07-01

    A method is proposed to reconstruct a four-dimensional (4D) dose distribution using phase matching of measured cine images to precalculated images of electronic portal imaging device (EPID). (1) A phantom, designed to simulate a tumor in lung (a polystyrene block with a 3 cm diameter embedded in cork), was placed on a sinusoidally moving platform with an amplitude of 1 cm and a period of 4 s. Ten-phase 4D computed tomography (CT) images of the phantom were acquired. A planning target volume (PTV) was created by adding a margin of 1 cm around the internal target volume of the tumor. (2) Three beams were designed, which included a static beam, a theoretical dynamic beam, and a planning-optimized dynamic beam (PODB). While the theoretical beam was made by manually programming a simplistic sliding leaf motion, the planning-optimized beam was obtained from treatment planning. From the three beams, three-dimensional (3D) doses on the phantom were calculated; 4D dose was calculated by means of the ten phase images (integrated over phases afterward); serving as "reference" images, phase-specific EPID dose images under the lung phantom were also calculated for each of the ten phases. (3) Cine EPID images were acquired while the beams were irradiated to the moving phantom. (4) Each cine image was phase-matched to a phase-specific CT image at which common irradiation occurred by intercomparing the cine image with the reference images. (5) Each cine image was used to reconstruct dose in the phase-matched CT image, and the reconstructed doses were summed over all phases. (6) The summation was compared with forwardly calculated 4D and 3D dose distributions. Accounting for realistic situations, intratreatment breathing irregularity was simulated by assuming an amplitude of 0.5 cm for the phantom during a portion of breathing trace in which the phase matching could not be performed. Intertreatment breathing irregularity between the time of treatment and the time of planning CT was considered by utilizing the same reduced amplitude when the phantom was irradiated. To examine the phase matching in a humanoid environment, the matching was also performed in a digital phantom (4D XCAT phantom). For the static, the theoretical, and the planning-optimized dynamic beams, the 4D reconstructed doses showed agreement with the forwardly calculated 4D doses within the gamma pass rates of 92.7%, 100%, and 98.1%, respectively, at the isocenter plane given by 3%/3 mm criteria. Excellent agreement in dose volume histogram of PTV and lung-PTV was also found between the two 4D doses, while substantial differences were found between the 3D and the 4D doses. The significant breathing irregularities modeled in this study were found not to be noticeably affecting the reconstructed dose. The phase matching was performed equally well in a digital phantom. The method of retrospective phase determination of a moving object under irradiation provided successful 4D dose reconstruction. This method will provide accurate quality assurance and facilitate adaptive therapy when distinguishable objects such as well-defined tumors, diaphragm, and organs with markers (pancreas and liver) are covered by treatment beam apertures.

  17. Imaging the Human Aqueous Humor Outflow Pathway in Human Eyes by Three Dimensional Micro-Computed Tomography (3D micro-CT)

    PubMed Central

    Hann, Cheryl R.; Bentley, Michael D.; Vercnocke, Andrew; Ritman, Erik L.; Fautsch, Michael P.

    2011-01-01

    The site of outflow resistance leading to elevated intraocular pressure in primary open angle glaucoma is believed to be located in the region of Schlemm’s canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecular outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde, and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide, and scanned with 3D micro-CT at 2 µm or 5 µm voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 ± 5 µm. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 ± 13 µm. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm’s canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm’s canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for noninvasive study of the role of the trabecular outflow pathway as a whole unit. PMID:21187085

  18. Imaging the Aqueous Humor Outflow Pathway in Human Eyes by Three-dimensional Micro-computed Tomography (3D micro-CT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C Hann; M Bentley; A Vercnocke

    2011-12-31

    The site of outflow resistance leading to elevated intraocular pressure in primary open-angle glaucoma is believed to be located in the region of Schlemm's canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecularmore » outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide and scanned with 3D micro-CT at 2 {mu}m or 5 {mu}m voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 {+-} 5 {mu}m. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 {+-} 13 {mu}m. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm's canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm's canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for non-invasive study of the role of the trabecular outflow pathway as a whole unit.« less

  19. Innovations in coaching and mentoring: implications for nurse leadership development.

    PubMed

    Fielden, Sandra L; Davidson, Marilyn J; Sutherland, Valerie J

    2009-05-01

    This longitudinal study sought to examine ways in which coaching and mentoring relationships impact on the professional development of nurses in terms of career and leadership behaviours, and evaluating the differences and similarities between those coaching and mentoring relationships. According to the UK government, leadership in nursing is essential to the improvement of service delivery, and the development and training of all nurses is vital in achieving effective change. A coaching and mentoring programme was used to explore the comparative advantages of these two approaches for the leadership development of nurses in acute, primary care and mental health settings. A longitudinal in-depth study was conducted to measure differences and similarities between the mentoring and coaching process as a result of a six-month coaching/mentoring programme. Five nurses from six UK Health Care Trusts were allocated to a coaching group (n = 15) or a mentoring group (n = 15), these were coached or mentored by a member of the senior directorate from their own Trust. Qualitative and quantitative data were collected at three time points (T1 = baseline, T2 = 4 months and T3 = 9 months) using semi-structured interviews and questionnaires. While mentoring was perceived to be 'support' and coaching was described as 'action', descriptions of the actual process and content were quite similar. However, while both groups reported significant development in terms of career development, leadership skills and capabilities, mentees reported the highest level of development with significantly higher scores in eight areas of leadership and management and in three areas of career impact. Implications for nurses and health services are discussed.

  20. Coach-led prevention programs are effective in reducing anterior cruciate ligament injury risk in female athletes: A number-needed-to-treat analysis.

    PubMed

    Pfile, K R; Curioz, B

    2017-12-01

    The purpose of this study was to determine whether the effectiveness of an anterior cruciate ligament (ACL) prevention program is impacted by the individual(s) directing the program. A number-needed-to-treat analysis compared the effectiveness of injury prevention measures when either directed by a coach or a mixed leadership group consisting of coach and healthcare providers. Eleven studies were included for analysis. Number-needed-to-treat and relative risk reduction (RRR) were calculated for each study and data sets were pooled based on the intervention leader. Quality of evidence was determined by assessing individual studies (PEDro score x¯=4.55±1.97, range=2-7), applying the Oxford Centre for Evidence-Based Medicine Levels of Evidence (CEBM=2a), and the Strength of Recommendation Taxonomy (SORT=Level B). The mixed leadership group studies' RRR=48.2% (95% confidence interval (CI)=22-65) and a number-needed-to-benefit of 120 (CI=73-303) while the coach-led group's RRR=58.4% (CI=40-71) and a number-needed-to-benefit=133 (CI=96-217). These results demonstrate that a coach-led ACL injury prevention program approach is as effective as a mixed group leadership approach. Coach-led prevention programs can be more widely implemented; however, it is imperative to ensure adequate training is in place prior to implementation of such intervention. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Reappraisal of Pediatric Diastatic Skull Fractures in the 3-Dimensional CT Era: Clinical Characteristics and Comparison of Diagnostic Accuracy of Simple Skull X-Ray, 2-Dimensional CT, and 3-Dimensional CT.

    PubMed

    Sim, Sook Young; Kim, Hyun Gi; Yoon, Soo Han; Choi, Jong Wook; Cho, Sung Min; Choi, Mi Sun

    2017-12-01

    Diastatic skull fractures (DSFs) in children are difficult to detect in skull radiographs before they develop into growing skull fractures; therefore, little information is available on this topic. However, recent advances in 3-dimensional (3D) computed tomography (CT) imaging technology have enabled more accurate diagnoses of almost all forms of skull fracture. The present study was undertaken to document the clinical characteristics of DSFs in children and to determine whether 3D CT enhances diagnostic accuracy. Two hundred and ninety-two children younger than 12 years with skull fractures underwent simple skull radiography, 2-dimensional (2D) CT, and 3DCT. Results were compared with respect to fracture type, location, associated lesions, and accuracy of diagnosis. DSFs were diagnosed in 44 (15.7%) of children with skull fractures. Twenty-two patients had DSFs only, and the other 22 had DSFs combined with compound or mixed skull fractures. The most common fracture locations were the occipitomastoid (25%) and lambdoid (15.9%). Accompanying lesions consisted of subgaleal hemorrhages (42/44), epidural hemorrhages (32/44), pneumocephalus (17/44), and subdural hemorrhages (3/44). A total of 17 surgical procedures were performed on 15 of the 44 patients. Fourteen and 19 patients were confirmed to have DSFs by skull radiography and 2D CT, respectively, but 3D CT detected DSFs in 43 of the 44 children (P < 0.001). 3D CT was found to be markedly superior to skull radiography or 2D CT for detecting DSFs. This finding indicates that 3D CT should be used routinely rather than 2D CT for the assessment of pediatric head trauma. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Validation of a novel CARTOSEG™ segmentation module software for contrast-enhanced computed tomography-guided radiofrequency ablation in patients with atrial fibrillation.

    PubMed

    Imanli, Hasan; Bhatty, Shaun; Jeudy, Jean; Ghzally, Yousra; Ume, Kiddy; Vunnam, Rama; Itah, Refael; Amit, Mati; Duell, John; See, Vincent; Shorofsky, Stephen; Dickfeld, Timm M

    2017-11-01

    Visualization of left atrial (LA) anatomy using image integration modules has been associated with decreased radiation exposure and improved procedural outcome when used for guidance of pulmonary vein isolation (PVI) in atrial fibrillation (AF) ablation. We evaluated the CARTOSEG™ CT Segmentation Module (Biosense Webster, Inc.) that offers a new CT-specific semiautomatic reconstruction of the atrial endocardium. The CARTOSEG™ CT Segmentation Module software was assessed prospectively in 80 patients undergoing AF ablation. Using preprocedural contrast-enhanced computed tomography (CE-CT), cardiac chambers, coronary sinus (CS), and esophagus were semiautomatically segmented. Segmentation quality was assessed from 1 (poor) to 4 (excellent). The reconstructed structures were registered with the electroanatomic map (EAM). PVI was performed using the registered 3D images. Semiautomatic reconstruction of the heart chambers was successfully performed in all 80 patients with AF. CE-CT DICOM file import, semiautomatic segmentation of cardiac chambers, esophagus, and CS was performed in 185 ± 105, 18 ± 5, 119 ± 47, and 69 ± 19 seconds, respectively. Average segmentation quality was 3.9 ± 0.2, 3.8 ± 0.3, and 3.8 ± 0.2 for LA, esophagus, and CS, respectively. Registration accuracy between the EAM and CE-CT-derived segmentation was 4.2 ± 0.9 mm. Complications consisted of one perforation (1%) which required pericardiocentesis, one increased pericardial effusion treated conservatively (1%), and one early termination of ablation due to thrombus formation on the ablation sheath without TIA/stroke (1%). All targeted PVs (n  =  309) were successfully isolated. The novel CT- CARTOSEG™ CT Segmentation Module enables a rapid and reliable semiautomatic 3D reconstruction of cardiac chambers and adjacent anatomy, which facilitates successful and safe PVI. © 2017 Wiley Periodicals, Inc.

  3. XCAT/DRASIM: a realistic CT/human-model simulation package

    NASA Astrophysics Data System (ADS)

    Fung, George S. K.; Stierstorfer, Karl; Segars, W. Paul; Taguchi, Katsuyuki; Flohr, Thomas G.; Tsui, Benjamin M. W.

    2011-03-01

    The aim of this research is to develop a complete CT/human-model simulation package by integrating the 4D eXtended CArdiac-Torso (XCAT) phantom, a computer generated NURBS surface based phantom that provides a realistic model of human anatomy and respiratory and cardiac motions, and the DRASIM (Siemens Healthcare) CT-data simulation program. Unlike other CT simulation tools which are based on simple mathematical primitives or voxelized phantoms, this new simulation package has the advantages of utilizing a realistic model of human anatomy and physiological motions without voxelization and with accurate modeling of the characteristics of clinical Siemens CT systems. First, we incorporated the 4D XCAT anatomy and motion models into DRASIM by implementing a new library which consists of functions to read-in the NURBS surfaces of anatomical objects and their overlapping order and material properties in the XCAT phantom. Second, we incorporated an efficient ray-tracing algorithm for line integral calculation in DRASIM by computing the intersection points of the rays cast from the x-ray source to the detector elements through the NURBS surfaces of the multiple XCAT anatomical objects along the ray paths. Third, we evaluated the integrated simulation package by performing a number of sample simulations of multiple x-ray projections from different views followed by image reconstruction. The initial simulation results were found to be promising by qualitative evaluation. In conclusion, we have developed a unique CT/human-model simulation package which has great potential as a tool in the design and optimization of CT scanners, and the development of scanning protocols and image reconstruction methods for improving CT image quality and reducing radiation dose.

  4. Automatic cerebrospinal fluid segmentation in non-contrast CT images using a 3D convolutional network

    NASA Astrophysics Data System (ADS)

    Patel, Ajay; van de Leemput, Sil C.; Prokop, Mathias; van Ginneken, Bram; Manniesing, Rashindra

    2017-03-01

    Segmentation of anatomical structures is fundamental in the development of computer aided diagnosis systems for cerebral pathologies. Manual annotations are laborious, time consuming and subject to human error and observer variability. Accurate quantification of cerebrospinal fluid (CSF) can be employed as a morphometric measure for diagnosis and patient outcome prediction. However, segmenting CSF in non-contrast CT images is complicated by low soft tissue contrast and image noise. In this paper we propose a state-of-the-art method using a multi-scale three-dimensional (3D) fully convolutional neural network (CNN) to automatically segment all CSF within the cranial cavity. The method is trained on a small dataset comprised of four manually annotated cerebral CT images. Quantitative evaluation of a separate test dataset of four images shows a mean Dice similarity coefficient of 0.87 +/- 0.01 and mean absolute volume difference of 4.77 +/- 2.70 %. The average prediction time was 68 seconds. Our method allows for fast and fully automated 3D segmentation of cerebral CSF in non-contrast CT, and shows promising results despite a limited amount of training data.

  5. 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling

    NASA Astrophysics Data System (ADS)

    Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing

    2016-02-01

    A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp-Davis-Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations.

  6. 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling.

    PubMed

    Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing

    2016-02-07

    A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp-Davis-Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations.

  7. 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling

    PubMed Central

    Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing

    2016-01-01

    A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp–Davis–Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations. PMID:26758496

  8. Sports Nutrition Knowledge Among Collegiate Athletes, Coaches, Athletic Trainers, and Strength and Conditioning Specialists

    PubMed Central

    Torres-McGehee, Toni M.; Pritchett, Kelly L.; Zippel, Deborah; Minton, Dawn M.; Cellamare, Adam; Sibilia, Mike

    2012-01-01

    Context: Coaches, athletic trainers (ATs), strength and conditioning specialists (SCSs), and registered dietitians are common nutrition resources for athletes, but coaches, ATs, and SCSs might offer only limited nutrition information. Little research exists about sports nutrition knowledge and current available resources for nutrition information for athletes, coaches, ATs, and SCSs. Objective: To identify resources of nutrition information that athletes, coaches, ATs, and SCSs use; to examine nutrition knowledge among athletes, coaches, ATs, and SCSs; and to determine confidence levels in the correctness of nutrition knowledge questions within all groups. Design: Cross-sectional study. Setting: National Collegiate Athletic Association Division I, II, and III institutions across the United States. Patients and Other Participants: The 579 participants consisted of athletes (n = 185), coaches (n = 131), ATs (n = 192), and SCSs (n = 71). Main Outcome Measure(s): Participants answered questions about nutrition resources and domains regarding basic nutrition, supplements and performance, weight management, and hydration. Adequate sports nutrition knowledge was defined as an overall score of 75% in all domains (highest achievable score was 100%). Results: Participants averaged 68.5% in all domains. The ATs (77.8%) and SCSs (81.6%) had the highest average scores. Adequate knowledge was found in 35.9% of coaches, 71.4% of ATs, 83.1% of SCSs, and only 9% of athletes. The most used nutrition resources for coaches, ATs, and SCSs were registered dietitians. Conclusions: Overall, we demonstrated that ATs and SCSs have adequate sports nutrition knowledge, whereas most coaches and athletes have inadequate knowledge. Athletes have frequent contact with ATs and SCSs; therefore, proper nutrition education among these staff members is critical. We suggest that proper nutrition programming should be provided for athletes, coaches, ATs, and SCSs. However, a separate nutrition program should be integrated for ATs and SCSs. This integrative approach is beneficial for the continuity of care, as both categories of professionals might be developing and integrating preventive or rehabilitative programs for athletes. PMID:22488287

  9. Knowledge, Attitudes, and Beliefs of Youth Sports Coaches Regarding Sport Volume Recommendations and Sport Specialization.

    PubMed

    Post, Eric G; Trigsted, Stephanie M; Schaefer, Daniel A; Cadmus-Bertram, Lisa A; Watson, Andrew M; McGuine, Timothy A; Brooks, M Alison; Bell, David R

    2018-02-22

    Overuse injuries in youth athletes are becoming increasingly common which may be a result of the prevalence of year-round specialized sport participation. Previous research has identified sport volume recommendations related to months per year, hours per week, and simultaneous participation in multiple sports leagues. Coaches are a primary influence on a youth athlete's decision to specialize in a single sport. Therefore, identifying coaches' baseline beliefs and perceptions is important for developing strategies to educate coaches about safe sport participation. A total of 253 youth sport coaches (207 males) completed an anonymous online questionnaire regarding knowledge of sport volume recommendations and attitudes and beliefs regarding sport specialization. Eligible participants were required to serve as a head or assistant coach of a youth sport team in the past 12 months whose members were between the ages of 12 and 18. Most coaches were unaware of recommendations regarding the maximum number of months per year (79.4%), hours per week in one sport (79.3%), or number of simultaneous leagues for an athlete to participate in to reduce injury (77.6%). Fewer than half (43.2%) of all coaches were "very" or "extremely" concerned about the risk of injury in youth sports. A majority (60.1%) believed that sport specialization was either "quite a bit" or "a great deal" of a problem. Two-thirds (67.2%) responded that year-round participation in a single sport was either "very" or "extremely" likely to increase an athlete's risk of injury. Although the responses to this survey were predominantly from coaches from one state, our results suggest that coaches are unaware of sport volume recommendations but are concerned about specialization. Future efforts are needed to communicate these recommendations to coaches in order to reduce the risk of overuse injury in youth sports.

  10. 3D intrathoracic region definition and its application to PET-CT analysis

    NASA Astrophysics Data System (ADS)

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.

    2014-03-01

    Recently developed integrated PET-CT scanners give co-registered multimodal data sets that offer complementary three-dimensional (3D) digital images of the chest. PET (positron emission tomography) imaging gives highly specific functional information of suspect cancer sites, while CT (X-ray computed tomography) gives associated anatomical detail. Because the 3D CT and PET scans generally span the body from the eyes to the knees, accurate definition of the intrathoracic region is vital for focusing attention to the central-chest region. In this way, diagnostically important regions of interest (ROIs), such as central-chest lymph nodes and cancer nodules, can be more efficiently isolated. We propose a method for automatic segmentation of the intrathoracic region from a given co-registered 3D PET-CT study. Using the 3D CT scan as input, the method begins by finding an initial intrathoracic region boundary for a given 2D CT section. Next, active contour analysis, driven by a cost function depending on local image gradient, gradient-direction, and contour shape features, iteratively estimates the contours spanning the intrathoracic region on neighboring 2D CT sections. This process continues until the complete region is defined. We next present an interactive system that employs the segmentation method for focused 3D PET-CT chest image analysis. A validation study over a series of PET-CT studies reveals that the segmentation method gives a Dice index accuracy of less than 98%. In addition, further results demonstrate the utility of the method for focused 3D PET-CT chest image analysis, ROI definition, and visualization.

  11. Efficacy of a Mindfulness-Based Mobile Application: a Randomized Waiting-List Controlled Trial.

    PubMed

    van Emmerik, Arnold A P; Berings, Fieke; Lancee, Jaap

    2018-01-01

    Although several hundreds of apps are available that (cl)aim to promote mindfulness, only a few methodologically sound studies have evaluated the efficacy of these apps. This randomized waiting-list controlled trial therefore tested the hypothesis that one such app (the VGZ Mindfulness Coach ) can achieve immediate and long-term improvements of mindfulness, quality of life, general psychiatric symptoms, and self-actualization. One hundred ninety-one experimental participants received the VGZ Mindfulness Coach, which offers 40 mindfulness exercises and background information about mindfulness without any form of therapeutic guidance. Compared to 186 control participants, they reported large (Cohen's d  = 0.77) and statistically significant increases of mindfulness after 8 weeks and small-to-medium increases of the Observing, Describing, Acting with awareness, Nonjudging, and Nonreactivity mindfulness facets as measured with the Five Facet Mindfulness Questionnaire (Cohen's d  = 0.66, 0.26, 0.49, 0.34, and 0.43, respectively). Also, there were large decreases of general psychiatric symptoms (GHQ-12; Cohen's d  = -0.68) and moderate increases of psychological, social, and environmental quality of life (WHOQOL-BREF; Cohen's d  = 0.38, 0.38, and 0.36, respectively). Except for social quality of life, these gains were maintained for at least 3 months. We conclude that it is possible to achieve durable positive effects on mindfulness, general psychiatric symptoms, and several aspects of quality of life at low costs with smartphone apps for mindfulness such as the VGZ Mindfulness Coach.

  12. The Design, Usability, and Feasibility of a Family-Focused Diabetes Self-Care Support mHealth Intervention for Diverse, Low-Income Adults with Type 2 Diabetes.

    PubMed

    Mayberry, Lindsay Satterwhite; Berg, Cynthia A; Harper, Kryseana J; Osborn, Chandra Y

    2016-01-01

    Family members' helpful and harmful actions affect adherence to self-care and glycemic control among adults with type 2 diabetes (T2D) and low socioeconomic status. Few family interventions for adults with T2D address harmful actions or use text messages to reach family members. Through user-centered design and iterative usability/feasibility testing, we developed a mHealth intervention for disadvantaged adults with T2D called FAMS. FAMS delivers phone coaching to set self-care goals and improve patient participant's (PP) ability to identify and address family actions that support/impede self-care. PPs receive text message support and can choose to invite a support person (SP) to receive text messages. We recruited 19 adults with T2D from three Federally Qualified Health Centers to use FAMS for two weeks and complete a feedback interview. Coach-reported data captured coaching success, technical data captured user engagement, and PP/SP interviews captured the FAMS experience. PPs were predominantly African American, 83% had incomes <$35,000, and 26% were married. Most SPs ( n = 7) were spouses/partners or adult children. PPs reported FAMS increased self-care and both PPs and SPs reported FAMS improved support for and communication about diabetes. FAMS is usable and feasible and appears to help patients manage self-care support, although some PPs may not have a SP.

  13. The Design, Usability, and Feasibility of a Family-Focused Diabetes Self-Care Support mHealth Intervention for Diverse, Low-Income Adults with Type 2 Diabetes

    PubMed Central

    Berg, Cynthia A.; Harper, Kryseana J.; Osborn, Chandra Y.

    2016-01-01

    Family members' helpful and harmful actions affect adherence to self-care and glycemic control among adults with type 2 diabetes (T2D) and low socioeconomic status. Few family interventions for adults with T2D address harmful actions or use text messages to reach family members. Through user-centered design and iterative usability/feasibility testing, we developed a mHealth intervention for disadvantaged adults with T2D called FAMS. FAMS delivers phone coaching to set self-care goals and improve patient participant's (PP) ability to identify and address family actions that support/impede self-care. PPs receive text message support and can choose to invite a support person (SP) to receive text messages. We recruited 19 adults with T2D from three Federally Qualified Health Centers to use FAMS for two weeks and complete a feedback interview. Coach-reported data captured coaching success, technical data captured user engagement, and PP/SP interviews captured the FAMS experience. PPs were predominantly African American, 83% had incomes <$35,000, and 26% were married. Most SPs (n = 7) were spouses/partners or adult children. PPs reported FAMS increased self-care and both PPs and SPs reported FAMS improved support for and communication about diabetes. FAMS is usable and feasible and appears to help patients manage self-care support, although some PPs may not have a SP. PMID:27891524

  14. In vivo verification of proton beam path by using post-treatment PET/CT imaging.

    PubMed

    Hsi, Wen C; Indelicato, Daniel J; Vargas, Carlos; Duvvuri, Srividya; Li, Zuofeng; Palta, Jatinder

    2009-09-01

    The purpose of this study is to establish the in vivo verification of proton beam path by using proton-activated positron emission distributions. A total of 50 PET/CT imaging studies were performed on ten prostate cancer patients immediately after daily proton therapy treatment through a single lateral portal. The PET/CT and planning CT were registered by matching the pelvic bones, and the beam path of delivered protons was defined in vivo by the positron emission distribution seen only within the pelvic bones, referred to as the PET-defined beam path. Because of the patient position correction at each fraction, the marker-defined beam path, determined by the centroid of implanted markers seen in the posttreatment (post-Tx) CT, is used for the planned beam path. The angular variation and discordance between the PET- and marker-defined paths were derived to investigate the intrafraction prostate motion. For studies with large discordance, the relative location between the centroid and pelvic bones seen in the post-Tx CT was examined. The PET/CT studies are categorized for distinguishing the prostate motion that occurred before or after beam delivery. The post-PET CT was acquired after PET imaging to investigate prostate motion due to physiological changes during the extended PET acquisition. The less than 2 degrees of angular variation indicates that the patient roll was minimal within the immobilization device. Thirty of the 50 studies with small discordance, referred as good cases, show a consistent alignment between the field edges and the positron emission distributions from the entrance to the distal edge. For those good cases, average displacements are 0.6 and 1.3 mm along the anterior-posterior (D(AP)) and superior-inferior (D(SI)) directions, respectively, with 1.6 mm standard deviations in both directions. For the remaining 20 studies demonstrating a large discordance (more than 6 mm in either D(AP) or D(SI)), 13 studies, referred as motion-after-Tx cases, also show large misalignment between the field edge and the positron emission distribution in lipomatous tissues around the prostate. These motion-after-Tx cases correspond to patients with large changes in volume of rectal gas between the post-Tx and the post-PET CTs. The standard deviations for D(AP) and D(SI) are 5.0 and 3.0 mm, respectively, for these motion-after-Tx cases. The final seven studies, referred to as position-error cases, which had a large discordance but no misalignment, were found to have deviations of 4.6 and 3.6 mm in D(AP) and D(SI), respectively. The position-error cases correspond to a large discrepancy on the relative location between the centroid and pelvic bones seen in post-Tx CT and recorded x-ray radiographs. Systematic analyses of proton-activated positron emission distributions provide patient-specific information on prostate motion (sigmaM) and patient position variability (sigmap) during daily proton beam delivery. The less than 2 mm of displacement variations in the good cases indicates that population-based values of sigmap and sigmaM, used in margin algorithms for treatment planning at the authors' institution are valid for the majority of cases. However, a small fraction of PET/CT studies (approximately 14%) with -4 mm displacement variations may require different margins. Such data are useful in establishing patient-specific planning target volume margins.

  15. Effect of deformable registration on the dose calculated in radiation therapy planning CT scans of lung cancer patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunliffe, Alexandra R.; Armato, Samuel G.; White, Bradley

    2015-01-15

    Purpose: To characterize the effects of deformable image registration of serial computed tomography (CT) scans on the radiation dose calculated from a treatment planning scan. Methods: Eighteen patients who received curative doses (≥60 Gy, 2 Gy/fraction) of photon radiation therapy for lung cancer treatment were retrospectively identified. For each patient, a diagnostic-quality pretherapy (4–75 days) CT scan and a treatment planning scan with an associated dose map were collected. To establish correspondence between scan pairs, a researcher manually identified anatomically corresponding landmark point pairs between the two scans. Pretherapy scans then were coregistered with planning scans (and associated dose maps)more » using the demons deformable registration algorithm and two variants of the Fraunhofer MEVIS algorithm (“Fast” and “EMPIRE10”). Landmark points in each pretherapy scan were automatically mapped to the planning scan using the displacement vector field output from each of the three algorithms. The Euclidean distance between manually and automatically mapped landmark points (d{sub E}) and the absolute difference in planned dose (|ΔD|) were calculated. Using regression modeling, |ΔD| was modeled as a function of d{sub E}, dose (D), dose standard deviation (SD{sub dose}) in an eight-pixel neighborhood, and the registration algorithm used. Results: Over 1400 landmark point pairs were identified, with 58–93 (median: 84) points identified per patient. Average |ΔD| across patients was 3.5 Gy (range: 0.9–10.6 Gy). Registration accuracy was highest using the Fraunhofer MEVIS EMPIRE10 algorithm, with an average d{sub E} across patients of 5.2 mm (compared with >7 mm for the other two algorithms). Consequently, average |ΔD| was also lowest using the Fraunhofer MEVIS EMPIRE10 algorithm. |ΔD| increased significantly as a function of d{sub E} (0.42 Gy/mm), D (0.05 Gy/Gy), SD{sub dose} (1.4 Gy/Gy), and the algorithm used (≤1 Gy). Conclusions: An average error of <4 Gy in radiation dose was introduced when points were mapped between CT scan pairs using deformable registration, with the majority of points yielding dose-mapping error <2 Gy (approximately 3% of the total prescribed dose). Registration accuracy was highest using the Fraunhofer MEVIS EMPIRE10 algorithm, resulting in the smallest errors in mapped dose. Dose differences following registration increased significantly with increasing spatial registration errors, dose, and dose gradient (i.e., SD{sub dose}). This model provides a measurement of the uncertainty in the radiation dose when points are mapped between serial CT scans through deformable registration.« less

  16. Correspondence model-based 4D VMAT dose simulation for analysis of local metastasis recurrence after extracranial SBRT

    NASA Astrophysics Data System (ADS)

    Sothmann, T.; Gauer, T.; Wilms, M.; Werner, R.

    2017-12-01

    The purpose of this study is to introduce a novel approach to incorporate patient-specific breathing variability information into 4D dose simulation of volumetric arc therapy (VMAT)-based stereotactic body radiotherapy (SBRT) of extracranial metastases. Feasibility of the approach is illustrated by application to treatment planning and motion data of lung and liver metastasis patients. The novel 4D dose simulation approach makes use of a regression-based correspondence model that allows representing patient motion variability by breathing signal-steered interpolation and extrapolation of deformable image registration motion fields. To predict the internal patient motion during treatment with only external breathing signal measurements being available, the patients’ internal motion information and external breathing signals acquired during 4D CT imaging were correlated. Combining the correspondence model, patient-specific breathing signal measurements during treatment and time-resolved information about dose delivery, reconstruction of a motion variability-affected dose becomes possible. As a proof of concept, the proposed approach is illustrated by a retrospective 4D simulation of VMAT-based SBRT treatment of ten patients with 15 treated lung and liver metastases and known clinical endpoints for the individual metastases (local metastasis recurrence yes/no). Resulting 4D-simulated dose distributions were compared to motion-affected dose distributions estimated by standard 4D CT-only dose accumulation and the originally (i.e. statically) planned dose distributions by means of GTV D98 indices (dose to 98% of the GTV volume). A potential linkage of metastasis-specific endpoints to differences between GTV D98 indices of planned and 4D-simulated dose distributions was analyzed.

  17. TH-C-BRD-06: A Novel MRI Based CT Artifact Correction Method for Improving Proton Range Calculation in the Presence of Severe CT Artifacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, P; Schreibmann, E; Fox, T

    2014-06-15

    Purpose: Severe CT artifacts can impair our ability to accurately calculate proton range thereby resulting in a clinically unacceptable treatment plan. In this work, we investigated a novel CT artifact correction method based on a coregistered MRI and investigated its ability to estimate CT HU and proton range in the presence of severe CT artifacts. Methods: The proposed method corrects corrupted CT data using a coregistered MRI to guide the mapping of CT values from a nearby artifact-free region. First patient MRI and CT images were registered using 3D deformable image registration software based on B-spline and mutual information. Themore » CT slice with severe artifacts was selected as well as a nearby slice free of artifacts (e.g. 1cm away from the artifact). The two sets of paired MRI and CT images at different slice locations were further registered by applying 2D deformable image registration. Based on the artifact free paired MRI and CT images, a comprehensive geospatial analysis was performed to predict the correct CT HU of the CT image with severe artifact. For a proof of concept, a known artifact was introduced that changed the ground truth CT HU value up to 30% and up to 5cm error in proton range. The ability of the proposed method to recover the ground truth was quantified using a selected head and neck case. Results: A significant improvement in image quality was observed visually. Our proof of concept study showed that 90% of area that had 30% errors in CT HU was corrected to 3% of its ground truth value. Furthermore, the maximum proton range error up to 5cm was reduced to 4mm error. Conclusion: MRI based CT artifact correction method can improve CT image quality and proton range calculation for patients with severe CT artifacts.« less

  18. Banking, Technology Workers and Their Career Development.

    ERIC Educational Resources Information Center

    Armstrong, Lesley; West, Jim

    2001-01-01

    An Australian bank developed a four-stage career development strategy for information technology workers: (1) career coaching sessions with executives; (2) career coaching seminars for line managers and team leaders; (3) staff career planning workshops; and (4) online career development support. The program resulted in increased satisfaction,…

  19. The safety and efficacy of microwave ablation for the treatment of CRC pulmonary metastases.

    PubMed

    Cheng, Gui; Shi, Liangrong; Qiang, Weiguang; Wu, Jun; Ji, Mei; Lu, Qicheng; Li, Xiaodong; Xu, Bin; Jiang, Jingting; Wu, Changping

    2017-11-16

    Microwave ablation (MWA) is a recently developed thermal ablation technique that has been used for the treatment of different types of tumours. In the present study, we retrospectively evaluated the safety and efficacy of CT-guided percutaneous MWA for the treatment of colorectal cancer (CRC) pulmonary metastases. From June 2010 to June 2015, 48 unresectable lesions in 32 patients with CRC pulmonary metastases were subjected to CT-guided MWA. Imaging follow-up was with contrast-enhanced CT and 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT. Oncologic imaging showed that 42 (87.5%) of the 48 lesions in the 32 patients were completely ablated. Needle track metastatic seeding was not found, and no patient deaths occurred within 30 d after ablation. The mean hospital stay was 3 d (range, 2-7 d). Pneumothorax was the most frequent complication and occurred in 6 (12.5%) of the 48 lesions. The median survival time was 31 months (95% CI: 15.4-46.6). The 1-, 2- and 3-year survival rates were 79.5%, 63.1% and 44.4%, respectively. Univariate Cox regression analysis showed that tumour size, disease-free interval (DFI) and number of tumours were significantly related to the overall survival time (p = .007, p = .022 and p = .030, respectively). Multivariate analysis showed that tumour size was an independent prognostic factor for survival (p = .017). CT-guided percutaneous MWA is a safe and effective minimally invasive method for treating CRC pulmonary metastases.

  20. Direct Visuo-Haptic 4D Volume Rendering Using Respiratory Motion Models.

    PubMed

    Fortmeier, Dirk; Wilms, Matthias; Mastmeyer, Andre; Handels, Heinz

    2015-01-01

    This article presents methods for direct visuo-haptic 4D volume rendering of virtual patient models under respiratory motion. Breathing models are computed based on patient-specific 4D CT image data sequences. Virtual patient models are visualized in real-time by ray casting based rendering of a reference CT image warped by a time-variant displacement field, which is computed using the motion models at run-time. Furthermore, haptic interaction with the animated virtual patient models is provided by using the displacements computed at high rendering rates to translate the position of the haptic device into the space of the reference CT image. This concept is applied to virtual palpation and the haptic simulation of insertion of a virtual bendable needle. To this aim, different motion models that are applicable in real-time are presented and the methods are integrated into a needle puncture training simulation framework, which can be used for simulated biopsy or vessel puncture in the liver. To confirm real-time applicability, a performance analysis of the resulting framework is given. It is shown that the presented methods achieve mean update rates around 2,000 Hz for haptic simulation and interactive frame rates for volume rendering and thus are well suited for visuo-haptic rendering of virtual patients under respiratory motion.

  1. Feasibility of wall stress analysis of abdominal aortic aneurysms using three-dimensional ultrasound.

    PubMed

    Kok, Annette M; Nguyen, V Lai; Speelman, Lambert; Brands, Peter J; Schurink, Geert-Willem H; van de Vosse, Frans N; Lopata, Richard G P

    2015-05-01

    Abdominal aortic aneurysms (AAAs) are local dilations that can lead to a fatal hemorrhage when ruptured. Wall stress analysis of AAAs is a novel tool that has proven high potential to improve risk stratification. Currently, wall stress analysis of AAAs is based on computed tomography (CT) and magnetic resonance imaging; however, three-dimensional (3D) ultrasound (US) has great advantages over CT and magnetic resonance imaging in terms of costs, speed, and lack of radiation. In this study, the feasibility of 3D US as input for wall stress analysis is investigated. Second, 3D US-based wall stress analysis was compared with CT-based results. The 3D US and CT data were acquired in 12 patients (diameter, 35-90 mm). US data were segmented manually and compared with automatically acquired CT geometries by calculating the similarity index and Hausdorff distance. Wall stresses were simulated at P = 140 mm Hg and compared between both modalities. The similarity index of US vs CT was 0.75 to 0.91 (n = 12), with a median Hausdorff distance ranging from 4.8 to 13.9 mm, with the higher values found at the proximal and distal sides of the AAA. Wall stresses were in accordance with literature, and a good agreement was found between US- and CT-based median stresses and interquartile stresses, which was confirmed by Bland-Altman and regression analysis (n = 8). Wall stresses based on US were typically higher (+23%), caused by geometric irregularities due to the registration of several 3D volumes and manual segmentation. In future work, an automated US registration and segmentation approach is the essential point of improvement before pursuing large-scale patient studies. This study is a first step toward US-based wall stress analysis, which would be the modality of choice to monitor wall stress development over time because no ionizing radiation and contrast material are involved. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  2. Association of CYP2D6*10 (c.100C>T) polymorphisms with clinical outcome of breast cancer after tamoxifen adjuvant endocrine therapy in Chinese population.

    PubMed

    Lei, Lei; Wang, Xian; Wu, Xiao-Dan; Wang, Zeng; Chen, Zhan-Hong; Zheng, Ya-Bin; Wang, Xiao-Jia

    2016-01-01

    Tamoxifen is the most widely used adjuvant endocrine therapy for breast cancer. However, the pharmacogenetic effect of CYP2D6 on its efficacy remains unclear. Therefore, this study aimed to evaluate the association of CYP2D6*10 (c.100C>T) polymorphisms with clinical outcome in Chinese breast cancer patients. A total of 72 tamoxifen-treated early breast cancer patients were included in this study. CYP2D6*10 (c.100C>T) polymorphisms (C/C: wild type; T/T: homozygous mutant genotype T; C/T: heterozygote genotype C) were detected by pyrosequencing. The plasma concentrations of tamoxifen and its two major active metabolites were determined by liquid chromatography tandem mass spectrometry (LC-MS). Disease-free survival (DFS) and overall survival (OS) were assessed by Kaplan-Meier analysis, while the Cox proportional hazards model was used in multivariate tests for prognostic significance. We found that T/T carrier showed the lowest serum concentration of endoxifen as compared to C/C and C/T carriers (p<0.01). In the subgroup of patients below 40 years of age, T/T carriers appeared to have the shortest DFS and OS as compared to other genotype carriers (p<0.01). When genotypes (C/C, C/T and T/T carriers) and other clinical characteristics were adjusted, tumor size (>2 cm) and grades were independent prognostic factors for DFS but not OS (tumor size >2 cm: HR: 3.870, 95% CI: 1.045-14.330, P = 0.043; tumor grades: HR: 2.230, 95% CI: 1.090-4.562, P = 0.028). In conclusion, the T/T genotype is a negative prognostic factor in young breast cancer patients using tamoxifen. Tumor size (>2 cm) and grades are independent prognostic factors for DFS, when genotype of CYP2D6*10 (c.100C>T) is adjusted.

  3. Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy.

    PubMed

    Oechsner, Markus; Odersky, Leonhard; Berndt, Johannes; Combs, Stephanie Elisabeth; Wilkens, Jan Jakob; Duma, Marciana Nona

    2015-12-01

    The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences between 3D conformal radiotherapy and volumetric modulated arc therapy (VMAT) plans calculated on these CT datasets were determined. Twenty SBRT patients, ten lung cases and ten liver cases, were retrospectively selected for this study. Treatment plans were optimized on average intensity projection (AIP) CTs using 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT). Afterwards, the plans were copied to the planning CTs (PCT), maximum intensity projection (MIP) and mid-ventilation (MidV) CT datasets and dose was recalculated keeping all beam parameters and monitor units unchanged. Ipsilateral lung and liver volumes and dosimetric parameters for PTV (Dmean, D2, D98, D95), ipsilateral lung and liver (Dmean, V30, V20, V10) were determined and statistically analysed using Wilcoxon test. Significant but small mean differences were found for PTV dose between the CTs (lung SBRT: ≤2.5 %; liver SBRT: ≤1.6 %). MIPs achieved the smallest lung and the largest liver volumes. OAR mean doses in MIP plans were distinctly smaller than in the other CT datasets. Furthermore, overlapping of tumors with the diaphragm results in underestimated ipsilateral lung dose in MIP plans. Best agreement was found between AIP and MidV (lung SBRT). Overall, differences in liver SBRT were smaller than in lung SBRT and VMAT plans achieved slightly smaller differences than 3D-CRT plans. Only small differences were found for PTV parameters between the four CT datasets. Larger differences occurred for the doses to organs at risk (ipsilateral lung, liver) especially for MIP plans. No relevant differences were observed between 3D-CRT or VMAT plans. MIP CTs are not appropriate for OAR dose assessment. PCT, AIP and MidV resulted in similar doses. If a 4DCT is acquired PCT can be omitted using AIP or MidV for treatment planning.

  4. Web-Based Video-Coaching to Assist an Automated Computer-Tailored Physical Activity Intervention for Inactive Adults: A Randomized Controlled Trial

    PubMed Central

    Jennings, Cally; Plotnikoff, Ronald C; Vandelanotte, Corneel

    2016-01-01

    Background Web-based physical activity interventions that apply computer tailoring have shown to improve engagement and behavioral outcomes but provide limited accountability and social support for participants. It is unknown how video calls with a behavioral expert in a Web-based intervention will be received and whether they improve the effectiveness of computer-tailored advice. Objective The purpose of this study was to determine the feasibility and effectiveness of brief video-based coaching in addition to fully automated computer-tailored advice in a Web-based physical activity intervention for inactive adults. Methods Participants were assigned to one of the three groups: (1) tailoring + video-coaching where participants received an 8-week computer-tailored Web-based physical activity intervention (“My Activity Coach”) including 4 10-minute coaching sessions with a behavioral expert using a Web-based video-calling program (eg, Skype; n=52); (2) tailoring-only where participants received the same intervention without the coaching sessions (n=54); and (3) a waitlist control group (n=45). Demographics were measured at baseline, intervention satisfaction at week 9, and physical activity at baseline, week 9, and 6 months by Web-based self-report surveys. Feasibility was analyzed by comparing intervention groups on retention, adherence, engagement, and satisfaction using t tests and chi-square tests. Effectiveness was assessed using linear mixed models to compare physical activity changes between groups. Results A total of 23 tailoring + video-coaching participants, 30 tailoring-only participants, and 30 control participants completed the postintervention survey (83/151, 55.0% retention). A low percentage of tailoring + video-coaching completers participated in the coaching calls (11/23, 48%). However, the majority of those who participated in the video calls were satisfied with them (5/8, 71%) and had improved intervention adherence (9/11, 82% completed 3 or 4 modules vs 18/42, 43%, P=.01) and engagement (110 minutes spent on the website vs 78 minutes, P=.02) compared with other participants. There were no overall retention, adherence, engagement, and satisfaction differences between tailoring + video-coaching and tailoring-only participants. At 9 weeks, physical activity increased from baseline to postintervention in all groups (tailoring + video-coaching: +150 minutes/week; tailoring only: +123 minutes/week; waitlist control: +34 minutes/week). The increase was significantly higher in the tailoring + video-coaching group compared with the control group (P=.01). No significant difference was found between intervention groups and no significant between-group differences were found for physical activity change at 6 months. Conclusions Only small improvements were observed when video-coaching was added to computer-tailored advice in a Web-based physical activity intervention. However, combined Web-based video-coaching and computer-tailored advice was effective in comparison with a control group. More research is needed to determine whether Web-based coaching is more effective than stand-alone computer-tailored advice. Trial Registration Australian New Zealand Clinical Trials Registry (ACTRN): 12614000339651; http://www.anzctr.org.au/TrialSearch.aspx?searchTxt=ACTRN12614000339651+&isBasic=True (Archived by WebCite at http://www.webcitation.org/6jTnOv0Ld) PMID:27520283

  5. Experimental Testicular Torsion in a Rat Model: Effects of Treatment with Pausinystalia macroceras on Testis Functions.

    PubMed

    Ikebuaso, Afamefuna Donatus; Yama, Oshiozokhai Eboetse; Duru, F I O; Oyebadejo, S A

    2012-10-01

    Testicular torsion is a medical emergency with catastrophic sequelae that deserves the same treatment considerations and concerted efforts in research as any other complicated medical condition. The aim of this study was to investigate the effect of Pausinystalia macroceras (PM) bark extract on sperm quality and serum testosterone levels in testicular torsion in a rat model. Sixty-five (65) mature male Wistar rats apportioned randomly into four experimental groups of A to C; were further divided into four subgroups according to duration of torsion. Group D were the normal regular rats. Each group/subgroup comprised five rats. Testis maintained in the torted position (T) for 1, 2, 3 and 4 hr in Group A (subgroups: AT1+PM, AT2+PM, AT3+PM, and AT4+PM). Group B (sub- groups: B1+PM, B2+PM, B3+PM, B4+PM) were sham-operated animals, which did not undergo torsion and served as the sham control group. Group C subgroups: CT1, CT2, CT3 and CT4 were torted as in A. All animals (except groups C and D) were treated by PM extract (0.1 g/kg b.w. per day) for 56 days. Group D rats were fed distilled water. Serum testosterone concentrations and sperm quality (motility and count) were measured. Analyses of variance with Scheffe's post-hoc test were carried out on the data. PM extract had a positive effect (significant; p < 0.5) on the sperm count and motility in rats with testicular torsion compared to those not receiving the extract. There was also an increase in serum testosterone levels in the former groups. Treatment of rats following testicular torsion result to the enhancement of sperm production in comparison with untreated rats.

  6. Frameless fractionated stereotactic radiation therapy of intracranial lesions: impact of cone beam CT based setup correction on dose distribution

    PubMed Central

    2013-01-01

    Background The purpose of this study was to evaluate the impact of Cone Beam CT (CBCT) based setup correction on total dose distributions in fractionated frameless stereotactic radiation therapy of intracranial lesions. Methods Ten patients with intracranial lesions treated with 30 Gy in 6 fractions were included in this study. Treatment planning was performed with Oncentra® for a SynergyS® (Elekta Ltd, Crawley, UK) linear accelerator with XVI® Cone Beam CT, and HexaPOD™ couch top. Patients were immobilized by thermoplastic masks (BrainLab, Reuther). After initial patient setup with respect to lasers, a CBCT study was acquired and registered to the planning CT (PL-CT) study. Patient positioning was corrected according to the correction values (translational, rotational) calculated by the XVI® system. Afterwards a second CBCT study was acquired and registered to the PL-CT to confirm the accuracy of the corrections. An in-house developed software was used for rigid transformation of the PL-CT to the CBCT geometry, and dose calculations for each fraction were performed on the transformed CT. The total dose distribution was achieved by back-transformation and summation of the dose distributions of each fraction. Dose distributions based on PL-CT, CBCT (laser set-up), and final CBCT were compared to assess the influence of setup inaccuracies. Results The mean displacement vector, calculated over all treatments, was reduced from (4.3 ± 1.3) mm for laser based setup to (0.5 ± 0.2) mm if CBCT corrections were applied. The mean rotational errors around the medial-lateral, superior-inferior, anterior-posterior axis were reduced from (−0.1 ± 1.4)°, (0.1 ± 1.2)° and (−0.2 ± 1.0)°, to (0.04 ± 0.4)°, (0.01 ± 0.4)° and (0.02 ± 0.3)°. As a consequence the mean deviation between planned and delivered dose in the planning target volume (PTV) could be reduced from 12.3% to 0.4% for D95 and from 5.9% to 0.1% for Dav. Maximum deviation was reduced from 31.8% to 0.8% for D95, and from 20.4% to 0.1% for Dav. Conclusion Real dose distributions differ substantially from planned dose distributions, if setup is performed according to lasers only. Thermoplasic masks combined with a daily CBCT enabled a sufficient accuracy in dose distribution. PMID:23800172

  7. 46. DETAILS OF PLATFORMS & STAIRS, Y&D No. 107724 Scales ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. DETAILS OF PLATFORMS & STAIRS, Y&D No. 107724 Scales 3/4' = 1' and as indicated; July 2, 1929 - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  8. SU-G-JeP2-06: Dosimetric and Workflow Evaluation of First Commercial Synthetic CT Software for Clinical Use in Pelvis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyagi, N; Zhang, J; Happersett, L

    2016-06-15

    Purpose: evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy Methods: Twenty prostate patients underwent CT and MR simulation scans in treatment position on a 3T Philips scanner. The MR protocol consisted of a T2w turbo spin-echo for soft tissue contrast, a 2D balanced-fast field echo (b-FFE) for fiducial identification, a dual-echo 3D FFE B0 map for distortion analysis and a 3D mDIXON FFE sequence to generate syn-CT. Two echoes are acquired during mDIXON scan, allowing water, fat, and in-phase images to be derived using the frequency shift of the fat and water protons. Tissues were classifiedmore » as: air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned specific bulk HU values. Bone structures are segmented based on a pelvis bone atlas. Accuracy of syn-CT for patient treatment planning was analyzed by transferring the original plan and structures from the CT to syn-CT via rigid registration and recalculating dose. In addition, new IMRT plans were generated on the syn-CT using structures contoured on MR and transferred to the syn-CT. Accuracy of fiducial-based localization at the treatment machine performed using syn-CT or DRRs generated from syn-CT was assessed by comparing to orthogonal kV radiographs or CBCT. Results: Dosimetric comparison between CT and syn-CT was within 0.5% for all structures. The de-novo optimized plans generated on the syn-CT met our institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B0 maps was within 1mm and 0.4 mm in the body and prostate. The rectal and bladder outlines on the syn-CT were deemed sufficient for assessing rectal and bladder filling on the CBCT at the time of treatment. CBCT localization showed a median error of < ±1 mm in LR, AP and SI direction. Conclusion: MRI derived syn-CT can be used clinically in MR-alone planning and treatment process for prostate. Drs. Deasy, Hunt and Tyagi have Master research agreement with Philips healthcare.« less

  9. ART 3.5D: an algorithm to label arteries and veins from three-dimensional angiography.

    PubMed

    Barra, Beatrice; De Momi, Elena; Ferrigno, Giancarlo; Pero, Guglielmo; Cardinale, Francesco; Baselli, Giuseppe

    2016-10-01

    Preoperative three-dimensional (3-D) visualization of brain vasculature by digital subtraction angiography from computerized tomography (CT) in neurosurgery is gaining more and more importance, since vessels are the primary landmarks both for organs at risk and for navigation. Surgical embolization of cerebral aneurysms and arteriovenous malformations, epilepsy surgery, and stereoelectroencephalography are a few examples. Contrast-enhanced cone-beam computed tomography (CE-CBCT) represents a powerful facility, since it is capable of acquiring images in the operation room, shortly before surgery. However, standard 3-D reconstructions do not provide a direct distinction between arteries and veins, which is of utmost importance and is left to the surgeon's inference so far. Pioneering attempts by true four-dimensional (4-D) CT perfusion scans were already described, though at the expense of longer acquisition protocols, higher dosages, and sensible resolution losses. Hence, space is open to approaches attempting to recover the contrast dynamics from standard CE-CBCT, on the basis of anomalies overlooked in the standard 3-D approach. This paper aims at presenting algebraic reconstruction technique (ART) 3.5D, a method that overcomes the clinical limitations of 4-D CT, from standard 3-D CE-CBCT scans. The strategy works on the 3-D angiography, previously segmented in the standard way, and reprocesses the dynamics hidden in the raw data to recover an approximate dynamics in each segmented voxel. Next, a classification algorithm labels the angiographic voxels and artery or vein. Numerical simulations were performed on a digital phantom of a simplified 3-D vasculature with contrast transit. CE-CBCT projections were simulated and used for ART 3.5D testing. We achieved up to 90% classification accuracy in simulations, proving the feasibility of the presented approach for dynamic information recovery for arteries and veins segmentation.

  10. Training meals on wheels volunteers as health literacy coaches for older adults.

    PubMed

    Rubin, Donald L; Freimuth, Vicki S; Johnson, Sharon D; Kaley, Terry; Parmer, John

    2014-05-01

    Homebound older adults constitute a "hardly reached" population with respect to health communication. Older adults also typically suffer from health literacy challenges, which put them at increased risk of adverse health outcomes. Suboptimal interactions with providers are one such challenge. Interventions to improve interactive health literacy focus on training consumers/patients in question preparation and asking. Meals on Wheels volunteers are uniquely suited to coach their clients in such interaction strategies. Seventy-three Meals on Wheels volunteers participated in workshops to train as health literacy coaches. The 3- to 4-hour workshops included units on communicating with older adults, on the nature of health literacy, and on the process of interactive health literacy coaching. Participants viewed and discussed videos that modeled the targeted communication behaviors for older adult patients interacting with physicians. They role-played the coaching process. After 9 months, coaches participated in a "booster" session that included videos of ideal coaching practices. Evaluation questionnaires revealed that participants had favorable reactions to the workshops with respect to utility and interest. They especially appreciated learning communication skills and seeing realistic videos. A measure of knowledge about the workshop material revealed a significant increment at posttest. Fidelity of coaching practices with respect to workshop curriculum was confirmed. This training in interactive health literacy for community-based lay volunteers constitutes one way to implement the National Action Plan to Improve Health Literacy for one "hardly reached" population. An online tool kit containing all workshop materials is available.

  11. Changes in in vitro ruminal and post-ruminal degradation of tropical tannin-rich legumes due to varying levels of polyethylene glycol.

    PubMed

    Knowles, M M; Pabón, M L; Hess, H D; Carulla, J E

    2017-08-01

    We evaluated the effects of tannins from Flemingia macrophylla (CIAT 17403) and Calliandra calothyrsus (San Ramón CIAT 22310 and Patulul CIAT 22316) on in vitro ruminal and post-ruminal dry matter and apparent protein degradation. For each tannin source (legumes), different dosages of polyethylene glycol (PEG) (8000 Da) in McDougall buffer were added to achieve ratios of 0:3, 1:3, 2:3 and 3:3 PEG:condensed tannin (CT). Ruminal fluid mixed with McDougall buffer (1:4) was added to tubes containing only legume foliage (control) or PEG-treated legume foliage. For both Calliandra varieties, a higher ruminal dry matter degradation was observed at a PEG:CT ratio of 3:3. For F. macrophylla, no differences were found between 2:3 and 3:3 ratios (p > 0.05), indicating that a PEG:CT ratio of 2:3 might be enough to bind tannins. Increasing PEG:CT ratios increased apparent ruminal degraded protein and ammonia concentration (p < 0.0001) differing among species (species × ratio: p < 0.0001). The degradation of bypass crude protein (dBCP) was influenced by both legume type and PEG:CT ratio (p < 0.0001). For Patulul, as PEG:CT ratio increased, dBCP increased, but after tannin ratio of 2:3, there was not a significant increase, and for San Ramón, dBCP degradation was higher as PEG:CT ratio increased up to 2:3. For Flemingia, dBCP was higher than PEG:CT ratio of 0:3 but not different among 1:3, 2:3 or 3:3. Low concentration of CT (116 mg/g DM) increased the proportion of protein digested in the abomasum, but higher levels of CT (252 mg/g) clearly reduced the proportion of digested CP. For Flemingia, PEG:CT ratio of 2:3 is enough to inactivate tannins, while PEG:CT ratio of 3:3 was needed for Calliandra and consequently increased ruminal degradation of dry mater (rdDM), and crude protein (rdCP), total degradation of dry matter (tdDM), crude protein (tdCP) and ammonia levels. Journal of Animal Physiology and Animal Nutrition © 2017 Blackwell Verlag GmbH.

  12. Ultrafast and scalable cone-beam CT reconstruction using MapReduce in a cloud computing environment.

    PubMed

    Meng, Bowen; Pratx, Guillem; Xing, Lei

    2011-12-01

    Four-dimensional CT (4DCT) and cone beam CT (CBCT) are widely used in radiation therapy for accurate tumor target definition and localization. However, high-resolution and dynamic image reconstruction is computationally demanding because of the large amount of data processed. Efficient use of these imaging techniques in the clinic requires high-performance computing. The purpose of this work is to develop a novel ultrafast, scalable and reliable image reconstruction technique for 4D CBCT∕CT using a parallel computing framework called MapReduce. We show the utility of MapReduce for solving large-scale medical physics problems in a cloud computing environment. In this work, we accelerated the Feldcamp-Davis-Kress (FDK) algorithm by porting it to Hadoop, an open-source MapReduce implementation. Gated phases from a 4DCT scans were reconstructed independently. Following the MapReduce formalism, Map functions were used to filter and backproject subsets of projections, and Reduce function to aggregate those partial backprojection into the whole volume. MapReduce automatically parallelized the reconstruction process on a large cluster of computer nodes. As a validation, reconstruction of a digital phantom and an acquired CatPhan 600 phantom was performed on a commercial cloud computing environment using the proposed 4D CBCT∕CT reconstruction algorithm. Speedup of reconstruction time is found to be roughly linear with the number of nodes employed. For instance, greater than 10 times speedup was achieved using 200 nodes for all cases, compared to the same code executed on a single machine. Without modifying the code, faster reconstruction is readily achievable by allocating more nodes in the cloud computing environment. Root mean square error between the images obtained using MapReduce and a single-threaded reference implementation was on the order of 10(-7). Our study also proved that cloud computing with MapReduce is fault tolerant: the reconstruction completed successfully with identical results even when half of the nodes were manually terminated in the middle of the process. An ultrafast, reliable and scalable 4D CBCT∕CT reconstruction method was developed using the MapReduce framework. Unlike other parallel computing approaches, the parallelization and speedup required little modification of the original reconstruction code. MapReduce provides an efficient and fault tolerant means of solving large-scale computing problems in a cloud computing environment.

  13. Ultrafast and scalable cone-beam CT reconstruction using MapReduce in a cloud computing environment

    PubMed Central

    Meng, Bowen; Pratx, Guillem; Xing, Lei

    2011-01-01

    Purpose: Four-dimensional CT (4DCT) and cone beam CT (CBCT) are widely used in radiation therapy for accurate tumor target definition and localization. However, high-resolution and dynamic image reconstruction is computationally demanding because of the large amount of data processed. Efficient use of these imaging techniques in the clinic requires high-performance computing. The purpose of this work is to develop a novel ultrafast, scalable and reliable image reconstruction technique for 4D CBCT/CT using a parallel computing framework called MapReduce. We show the utility of MapReduce for solving large-scale medical physics problems in a cloud computing environment. Methods: In this work, we accelerated the Feldcamp–Davis–Kress (FDK) algorithm by porting it to Hadoop, an open-source MapReduce implementation. Gated phases from a 4DCT scans were reconstructed independently. Following the MapReduce formalism, Map functions were used to filter and backproject subsets of projections, and Reduce function to aggregate those partial backprojection into the whole volume. MapReduce automatically parallelized the reconstruction process on a large cluster of computer nodes. As a validation, reconstruction of a digital phantom and an acquired CatPhan 600 phantom was performed on a commercial cloud computing environment using the proposed 4D CBCT/CT reconstruction algorithm. Results: Speedup of reconstruction time is found to be roughly linear with the number of nodes employed. For instance, greater than 10 times speedup was achieved using 200 nodes for all cases, compared to the same code executed on a single machine. Without modifying the code, faster reconstruction is readily achievable by allocating more nodes in the cloud computing environment. Root mean square error between the images obtained using MapReduce and a single-threaded reference implementation was on the order of 10−7. Our study also proved that cloud computing with MapReduce is fault tolerant: the reconstruction completed successfully with identical results even when half of the nodes were manually terminated in the middle of the process. Conclusions: An ultrafast, reliable and scalable 4D CBCT/CT reconstruction method was developed using the MapReduce framework. Unlike other parallel computing approaches, the parallelization and speedup required little modification of the original reconstruction code. MapReduce provides an efficient and fault tolerant means of solving large-scale computing problems in a cloud computing environment. PMID:22149842

  14. Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vedam, S.; Archambault, L.; Starkschall, G.

    2007-11-15

    Four-dimensional (4D) computed tomography (CT) imaging has found increasing importance in the localization of tumor and surrounding normal structures throughout the respiratory cycle. Based on such tumor motion information, it is possible to identify the appropriate phase interval for respiratory gated treatment planning and delivery. Such a gating phase interval is determined retrospectively based on tumor motion from internal tumor displacement. However, respiratory-gated treatment is delivered prospectively based on motion determined predominantly from an external monitor. Therefore, the simulation gate threshold determined from the retrospective phase interval selected for gating at 4D CT simulation may not correspond to the deliverymore » gate threshold that is determined from the prospective external monitor displacement at treatment delivery. The purpose of the present work is to establish a relationship between the thresholds for respiratory gating determined at CT simulation and treatment delivery, respectively. One hundred fifty external respiratory motion traces, from 90 patients, with and without audio-visual biofeedback, are analyzed. Two respiratory phase intervals, 40%-60% and 30%-70%, are chosen for respiratory gating from the 4D CT-derived tumor motion trajectory. From residual tumor displacements within each such gating phase interval, a simulation gate threshold is defined based on (a) the average and (b) the maximum respiratory displacement within the phase interval. The duty cycle for prospective gated delivery is estimated from the proportion of external monitor displacement data points within both the selected phase interval and the simulation gate threshold. The delivery gate threshold is then determined iteratively to match the above determined duty cycle. The magnitude of the difference between such gate thresholds determined at simulation and treatment delivery is quantified in each case. Phantom motion tests yielded coincidence of simulation and delivery gate thresholds to within 0.3%. For patient data analysis, differences between simulation and delivery gate thresholds are reported as a fraction of the total respiratory motion range. For the smaller phase interval, the differences between simulation and delivery gate thresholds are 8{+-}11% and 14{+-}21% with and without audio-visual biofeedback, respectively, when the simulation gate threshold is determined based on the mean respiratory displacement within the 40%-60% gating phase interval. For the longer phase interval, corresponding differences are 4{+-}7% and 8{+-}15% with and without audio-visual biofeedback, respectively. Alternatively, when the simulation gate threshold is determined based on the maximum average respiratory displacement within the gating phase interval, greater differences between simulation and delivery gate thresholds are observed. A relationship between retrospective simulation gate threshold and prospective delivery gate threshold for respiratory gating is established and validated for regular and nonregular respiratory motion. Using this relationship, the delivery gate threshold can be reliably estimated at the time of 4D CT simulation, thereby improving the accuracy and efficiency of respiratory-gated radiation delivery.« less

  15. Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation.

    PubMed

    Vedam, S; Archambault, L; Starkschall, G; Mohan, R; Beddar, S

    2007-11-01

    Four-dimensional (4D) computed tomography (CT) imaging has found increasing importance in the localization of tumor and surrounding normal structures throughout the respiratory cycle. Based on such tumor motion information, it is possible to identify the appropriate phase interval for respiratory gated treatment planning and delivery. Such a gating phase interval is determined retrospectively based on tumor motion from internal tumor displacement. However, respiratory-gated treatment is delivered prospectively based on motion determined predominantly from an external monitor. Therefore, the simulation gate threshold determined from the retrospective phase interval selected for gating at 4D CT simulation may not correspond to the delivery gate threshold that is determined from the prospective external monitor displacement at treatment delivery. The purpose of the present work is to establish a relationship between the thresholds for respiratory gating determined at CT simulation and treatment delivery, respectively. One hundred fifty external respiratory motion traces, from 90 patients, with and without audio-visual biofeedback, are analyzed. Two respiratory phase intervals, 40%-60% and 30%-70%, are chosen for respiratory gating from the 4D CT-derived tumor motion trajectory. From residual tumor displacements within each such gating phase interval, a simulation gate threshold is defined based on (a) the average and (b) the maximum respiratory displacement within the phase interval. The duty cycle for prospective gated delivery is estimated from the proportion of external monitor displacement data points within both the selected phase interval and the simulation gate threshold. The delivery gate threshold is then determined iteratively to match the above determined duty cycle. The magnitude of the difference between such gate thresholds determined at simulation and treatment delivery is quantified in each case. Phantom motion tests yielded coincidence of simulation and delivery gate thresholds to within 0.3%. For patient data analysis, differences between simulation and delivery gate thresholds are reported as a fraction of the total respiratory motion range. For the smaller phase interval, the differences between simulation and delivery gate thresholds are 8 +/- 11% and 14 +/- 21% with and without audio-visual biofeedback, respectively, when the simulation gate threshold is determined based on the mean respiratory displacement within the 40%-60% gating phase interval. For the longer phase interval, corresponding differences are 4 +/- 7% and 8 +/- 15% with and without audiovisual biofeedback, respectively. Alternatively, when the simulation gate threshold is determined based on the maximum average respiratory displacement within the gating phase interval, greater differences between simulation and delivery gate thresholds are observed. A relationship between retrospective simulation gate threshold and prospective delivery gate threshold for respiratory gating is established and validated for regular and nonregular respiratory motion. Using this relationship, the delivery gate threshold can be reliably estimated at the time of 4D CT simulation, thereby improving the accuracy and efficiency of respiratory-gated radiation delivery.

  16. Computed Tomography Image Origin Identification Based on Original Sensor Pattern Noise and 3-D Image Reconstruction Algorithm Footprints.

    PubMed

    Duan, Yuping; Bouslimi, Dalel; Yang, Guanyu; Shu, Huazhong; Coatrieux, Gouenou

    2017-07-01

    In this paper, we focus on the "blind" identification of the computed tomography (CT) scanner that has produced a CT image. To do so, we propose a set of noise features derived from the image chain acquisition and which can be used as CT-scanner footprint. Basically, we propose two approaches. The first one aims at identifying a CT scanner based on an original sensor pattern noise (OSPN) that is intrinsic to the X-ray detectors. The second one identifies an acquisition system based on the way this noise is modified by its three-dimensional (3-D) image reconstruction algorithm. As these reconstruction algorithms are manufacturer dependent and kept secret, our features are used as input to train a support vector machine (SVM) based classifier to discriminate acquisition systems. Experiments conducted on images issued from 15 different CT-scanner models of 4 distinct manufacturers demonstrate that our system identifies the origin of one CT image with a detection rate of at least 94% and that it achieves better performance than sensor pattern noise (SPN) based strategy proposed for general public camera devices.

  17. SU-E-J-35: Using CBCT as the Alternative Method of Assessing ITV Volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, Y; Turian, J; Templeton, A

    2015-06-15

    Purpose To study the accuracy of Internal Target Volumes (ITVs) created on cone beam CT (CBCT) by comparing the visible target volume on CBCT to volumes (GTV, ITV, and PTV) outlined on free breathing (FB) CT and 4DCT. Methods A Quasar Cylindrical Motion Phantom with a 3cm diameter ball (14.14 cc) embedded within a cork insert was set up to simulate respiratory motion with a period of 4 seconds and amplitude of 2cm superioinferiorly and 1cm anterioposteriorly. FBCT and 4DCT images were acquired. A PTV-4D was created on the 4DCT by applying a uniform margin of 5mm to the ITV-CT.more » PTV-FB was created by applying a margin of the motion range plus 5mm, i.e. total of 1.5cm laterally and 2.5cm superioinferiorly to the GTV outlined on the FBCT. A dynamic conformal arc was planned to treat the PTV-FB with 1mm margin. A CBCT was acquired before the treatment, on which the target was delineated. During the treatment, the position of the target was monitored using the EPID in cine mode. Results ITV-CBCT and ITV-CT were measured to be 56.6 and 62.7cc, respectively, with a Dice Coefficient (DC) of 0.94 and disagreement in center of mass (COM) of 0.59 mm. On the other hand, GTV-FB was 11.47cc, 19% less than the known volume of the ball. PTV-FB and PTV-4D were 149 and 116 cc, with a DC of 0.71. Part of the ITV-CT was not enclosed by the PTV-FB despite the large margin. The cine EPID images have confirmed geometrical misses of the target. Similar under-coverage was observed in one clinical case and captured by the CBCT, where the implanted fiducials moved outside PTV-FB. Conclusion ITV-CBCT is in good agreement with ITV-CT. When 4DCT was not available, CBCT can be an effective alternative in determining and verifying the PTV margin.« less

  18. Assessment of regional ventilation and deformation using 4D-CT imaging for healthy human lungs during tidal breathing

    PubMed Central

    Jahani, Nariman; Choi, Jiwoong; Iyer, Krishna; Hoffman, Eric A.

    2015-01-01

    This study aims to assess regional ventilation, nonlinearity, and hysteresis of human lungs during dynamic breathing via image registration of four-dimensional computed tomography (4D-CT) scans. Six healthy adult humans were studied by spiral multidetector-row CT during controlled tidal breathing as well as during total lung capacity and functional residual capacity breath holds. Static images were utilized to contrast static vs. dynamic (deep vs. tidal) breathing. A rolling-seal piston system was employed to maintain consistent tidal breathing during 4D-CT spiral image acquisition, providing required between-breath consistency for physiologically meaningful reconstructed respiratory motion. Registration-derived variables including local air volume and anisotropic deformation index (ADI, an indicator of preferential deformation in response to local force) were employed to assess regional ventilation and lung deformation. Lobar distributions of air volume change during tidal breathing were correlated with those of deep breathing (R2 ≈ 0.84). Small discrepancies between tidal and deep breathing were shown to be likely due to different distributions of air volume change in the left and the right lungs. We also demonstrated an asymmetric characteristic of flow rate between inhalation and exhalation. With ADI, we were able to quantify nonlinearity and hysteresis of lung deformation that can only be captured in dynamic images. Nonlinearity quantified by ADI is greater during inhalation, and it is stronger in the lower lobes (P < 0.05). Lung hysteresis estimated by the difference of ADI between inhalation and exhalation is more significant in the right lungs than that in the left lungs. PMID:26316512

  19. A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections.

    PubMed

    Zhang, You; Yin, Fang-Fang; Segars, W Paul; Ren, Lei

    2013-12-01

    To develop a technique to estimate onboard 4D-CBCT using prior information and limited-angle projections for potential 4D target verification of lung radiotherapy. Each phase of onboard 4D-CBCT is considered as a deformation from one selected phase (prior volume) of the planning 4D-CT. The deformation field maps (DFMs) are solved using a motion modeling and free-form deformation (MM-FD) technique. In the MM-FD technique, the DFMs are estimated using a motion model which is extracted from planning 4D-CT based on principal component analysis (PCA). The motion model parameters are optimized by matching the digitally reconstructed radiographs of the deformed volumes to the limited-angle onboard projections (data fidelity constraint). Afterward, the estimated DFMs are fine-tuned using a FD model based on data fidelity constraint and deformation energy minimization. The 4D digital extended-cardiac-torso phantom was used to evaluate the MM-FD technique. A lung patient with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume, including changes of respiration amplitude, lesion size and lesion average-position, and phase shift between lesion and body respiratory cycle. The lesions were contoured in both the estimated and "ground-truth" onboard 4D-CBCT for comparison. 3D volume percentage-difference (VPD) and center-of-mass shift (COMS) were calculated to evaluate the estimation accuracy of three techniques: MM-FD, MM-only, and FD-only. Different onboard projection acquisition scenarios and projection noise levels were simulated to investigate their effects on the estimation accuracy. For all simulated patient and projection acquisition scenarios, the mean VPD (±S.D.)∕COMS (±S.D.) between lesions in prior images and "ground-truth" onboard images were 136.11% (±42.76%)∕15.5 mm (±3.9 mm). Using orthogonal-view 15°-each scan angle, the mean VPD∕COMS between the lesion in estimated and "ground-truth" onboard images for MM-only, FD-only, and MM-FD techniques were 60.10% (±27.17%)∕4.9 mm (±3.0 mm), 96.07% (±31.48%)∕12.1 mm (±3.9 mm) and 11.45% (±9.37%)∕1.3 mm (±1.3 mm), respectively. For orthogonal-view 30°-each scan angle, the corresponding results were 59.16% (±26.66%)∕4.9 mm (±3.0 mm), 75.98% (±27.21%)∕9.9 mm (±4.0 mm), and 5.22% (±2.12%)∕0.5 mm (±0.4 mm). For single-view scan angles of 3°, 30°, and 60°, the results for MM-FD technique were 32.77% (±17.87%)∕3.2 mm (±2.2 mm), 24.57% (±18.18%)∕2.9 mm (±2.0 mm), and 10.48% (±9.50%)∕1.1 mm (±1.3 mm), respectively. For projection angular-sampling-intervals of 0.6°, 1.2°, and 2.5° with the orthogonal-view 30°-each scan angle, the MM-FD technique generated similar VPD (maximum deviation 2.91%) and COMS (maximum deviation 0.6 mm), while sparser sampling yielded larger VPD∕COMS. With equal number of projections, the estimation results using scattered 360° scan angle were slightly better than those using orthogonal-view 30°-each scan angle. The estimation accuracy of MM-FD technique declined as noise level increased. The MM-FD technique substantially improves the estimation accuracy for onboard 4D-CBCT using prior planning 4D-CT and limited-angle projections, compared to the MM-only and FD-only techniques. It can potentially be used for the inter/intrafractional 4D-localization verification.

  20. A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, You; Yin, Fang-Fang; Ren, Lei

    2013-12-15

    Purpose: To develop a technique to estimate onboard 4D-CBCT using prior information and limited-angle projections for potential 4D target verification of lung radiotherapy.Methods: Each phase of onboard 4D-CBCT is considered as a deformation from one selected phase (prior volume) of the planning 4D-CT. The deformation field maps (DFMs) are solved using a motion modeling and free-form deformation (MM-FD) technique. In the MM-FD technique, the DFMs are estimated using a motion model which is extracted from planning 4D-CT based on principal component analysis (PCA). The motion model parameters are optimized by matching the digitally reconstructed radiographs of the deformed volumes tomore » the limited-angle onboard projections (data fidelity constraint). Afterward, the estimated DFMs are fine-tuned using a FD model based on data fidelity constraint and deformation energy minimization. The 4D digital extended-cardiac-torso phantom was used to evaluate the MM-FD technique. A lung patient with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume, including changes of respiration amplitude, lesion size and lesion average-position, and phase shift between lesion and body respiratory cycle. The lesions were contoured in both the estimated and “ground-truth” onboard 4D-CBCT for comparison. 3D volume percentage-difference (VPD) and center-of-mass shift (COMS) were calculated to evaluate the estimation accuracy of three techniques: MM-FD, MM-only, and FD-only. Different onboard projection acquisition scenarios and projection noise levels were simulated to investigate their effects on the estimation accuracy.Results: For all simulated patient and projection acquisition scenarios, the mean VPD (±S.D.)/COMS (±S.D.) between lesions in prior images and “ground-truth” onboard images were 136.11% (±42.76%)/15.5 mm (±3.9 mm). Using orthogonal-view 15°-each scan angle, the mean VPD/COMS between the lesion in estimated and “ground-truth” onboard images for MM-only, FD-only, and MM-FD techniques were 60.10% (±27.17%)/4.9 mm (±3.0 mm), 96.07% (±31.48%)/12.1 mm (±3.9 mm) and 11.45% (±9.37%)/1.3 mm (±1.3 mm), respectively. For orthogonal-view 30°-each scan angle, the corresponding results were 59.16% (±26.66%)/4.9 mm (±3.0 mm), 75.98% (±27.21%)/9.9 mm (±4.0 mm), and 5.22% (±2.12%)/0.5 mm (±0.4 mm). For single-view scan angles of 3°, 30°, and 60°, the results for MM-FD technique were 32.77% (±17.87%)/3.2 mm (±2.2 mm), 24.57% (±18.18%)/2.9 mm (±2.0 mm), and 10.48% (±9.50%)/1.1 mm (±1.3 mm), respectively. For projection angular-sampling-intervals of 0.6°, 1.2°, and 2.5° with the orthogonal-view 30°-each scan angle, the MM-FD technique generated similar VPD (maximum deviation 2.91%) and COMS (maximum deviation 0.6 mm), while sparser sampling yielded larger VPD/COMS. With equal number of projections, the estimation results using scattered 360° scan angle were slightly better than those using orthogonal-view 30°-each scan angle. The estimation accuracy of MM-FD technique declined as noise level increased.Conclusions: The MM-FD technique substantially improves the estimation accuracy for onboard 4D-CBCT using prior planning 4D-CT and limited-angle projections, compared to the MM-only and FD-only techniques. It can potentially be used for the inter/intrafractional 4D-localization verification.« less

Top